WorldWideScience

Sample records for goniometers

  1. Dual-goniometer system for channeling measurements

    International Nuclear Information System (INIS)

    Linden, M.; Hellborg, R.

    1986-03-01

    This paper describes a two-goniometer system for obtaining azimuthally averaged measurements in channeling experiments. The system consists of a tri-axial master goniometer and a bi-axial goniometer. Both goniometers are controlled by stepping motors. The alignment goniometer has a target holder, which permits the beam spot to be placed anywhere in a 6 x 6 mm 2 square on the target crystal without loosing the target orientation. The design, construction and operation of the goniometers as well as stepping motor control units and programs for computer control of the goniometers are described. Two control programs cover orientation of the target crystal and a number of other normal experimental conditions. (author)

  2. Design and construction of an automatic texture goniometer

    International Nuclear Information System (INIS)

    Lima, N.B. de; Pontes, E.W.; Monteiro, P.R.B.; Imakuma, K.

    1984-01-01

    The project and construction of a two-axis automatic goniometer, operated by step motors, adaptable to the scanning goniometer SG-7 or SG-8 fabricated by Rigaku-Deuki. To allow the operation of this texture goniometer, computer codes has been developed. (E.G.) [pt

  3. Contact Angle Goniometer

    Data.gov (United States)

    Federal Laboratory Consortium — Description:The FTA32 goniometer provides video-based contact angle and surface tension measurement. Contact angles are measured by fitting a mathematical expression...

  4. The Improved Dual-view Field Goniometer System FIGOS

    Directory of Open Access Journals (Sweden)

    Klaus I. Itten

    2008-08-01

    Full Text Available In spectrodirectional Remote Sensing (RS the Earth’s surface reflectance characteristics are studied by means of their angular dimensions. Almost all natural surfaces exhibit an individual anisotropic reflectance behaviour due to the contrast between the optical properties of surface elements and background and the geometric surface properties of the observed scene. The underlying concept, which describes the reflectance characteristic of a specific surface area, is called the bidirectional reflectance distribution function (BRDF. BRDF knowledge is essential for both correction of directional effects in RS data and quantitative retrieval of surface parameters. Ground-based spectrodirectional measurements are usually performed with goniometer systems. An accurate retrieval of the bidirectional reflectance factors (BRF from field goniometer measurements requires hyperspectral knowledge of the angular distribution of the reflected and the incident radiation. However, prior to the study at hand, no operational goniometer system was able to fulfill this requirement. This study presents the first dual-view field goniometer system, which is able to simultaneously collect both the reflected and the incident radiation at high angular and spectral resolution and, thus, providing the necessary spectrodirectional datasets to accurately retrieve the surface specific BRF. Furthermore, the angular distribution of the incoming diffuse radiation is characterized for various atmospheric conditions and the BRF retrieval is performed for an artificial target and compared to laboratory spectrodirectional measurement results obtained with the same goniometer system. Suggestions for further improving goniometer systems are given and the need for intercalibration of various goniometers as well as for standardizing spectrodirectional measurements is expressed.

  5. Assessment of novel digital and smartphone goniometers for measurement of canine stifle joint angles.

    Science.gov (United States)

    Freund, Kristin A; Kieves, Nina R; Hart, Juliette L; Foster, Sasha A; Jeffery, Unity; Duerr, Felix M

    2016-07-01

    OBJECTIVE To evaluate accuracy and reliability of 3 novel goniometers for measurement of canine stifle joint angles and compare the results with those obtained with a universal goniometer (UG). SAMPLE 8 pelvic limbs from 4 canine cadavers. PROCEDURES Each limb was secured to a wooden platform at 3 arbitrarily selected fixed stifle joint angles. Goniometry was performed with 2 smartphone-based applications (novel goniometers A and B), a digital goniometer (novel goniometer C), and a UG; 3 evaluators performed measurements in triplicate for each angle with each device. Results were compared with stifle joint angle measurements on radiographs (used as a gold standard). Accuracy was determined by calculation of bias and total error, coefficients of variation were calculated to estimate reliability, and strength of linear association between radiographic and goniometer measurements was assessed by calculation of correlation coefficients. RESULTS Mean coefficient of variation was lowest for the UG (4.88%), followed by novel goniometers B (7.37%), A (7.57%), and C (12.71%). Correlation with radiographic measurements was highest for the UG (r = 0.97), followed by novel goniometers B (0.93), A (0.90), and C (0.78). Constant bias was present for all devices except novel goniometer B. The UG and novel goniometer A had positive constant bias; novel goniometer C had negative constant bias. Total error at 50° and 100° angles was > 5% for all devices. CONCLUSIONS AND CLINICAL RELEVANCE None of the devices accurately represented radiographically measured stifle joint angles. Additional veterinary studies are indicated prior to the use of novel goniometers in dogs.

  6. Goniometer head

    International Nuclear Information System (INIS)

    Dzhazairov-Kakhramanov, V.; Berger, V.D.; Kadyrzhanov, K.K.; Zarifov, R.A.

    1994-01-01

    The goniometer head is an electromechanical instrument that performs the independent transfer of a testing sample on three coordinate axes (X, Y, Z) within limits of ±8 mm and independent rotation relative of these directions. The instrument comprises a sample holder, bellows component and three electrometer drives. The sample holder rotates around the axes X and Y, and is installed on the central arm which rotates around axis Z. One characteristic of this instrument is its independence which allows its use in any camera for researches in the field of radiation physics. 2 figs

  7. Enhancement of the vibration stability of a microdiffraction goniometer

    International Nuclear Information System (INIS)

    Lee, S. H.; Preissner, C.; Lai, B.; Cai, Z.; Shu, D.

    2002-01-01

    High-precision instrumentation, such as that for x-ray diffraction, electron microscopy, scanning probe microscopy, and other optical micropositioning systems, requires the stability that comes from vibration-isolated support structures. Structure-born vibrations impede the acquisition of accurate experimental data through such high-precision instruments. At the Advanced Photon Source, a multiaxis goniometer is installed in the 2-ID-D station for synchrotron microdiffraction investigations. However, ground vibration can excite the kinematic movements of the goniometer linkages, resulting in critically contaminated experimental data. In this paper, the vibration behavior of the goniometer has been considered. Experimental vibration measurements were conducted to define the present vibration levels and determine the threshold sensitivity of the equipment. In addition, experimental modal tests were conducted and used to guide an analytical finite element analysis. Both results were used for finding the best way to reduce the vibration levels and to develop a vibration damping/isolation structure for the 2-ID-D goniometer. The device that was designed and tested could be used to reduce local vibration levels for the vibration isolation of similar high-precision instruments

  8. Toward a direct comparison of field and laboratory goniometer measurements

    NARCIS (Netherlands)

    Dangel, S.; Verstraete, M.; Schopfer, J.; Kneubuehler, M.; Schaepman, M.E.; Itten, K.I.

    2005-01-01

    Field and laboratory goniometers are widely used in the remote sensing community to assess spectrodirectional reflection properties of selected targets. Even when the same target and goniometer system are used, field and laboratory results cannot directly be compared due to inherent differences,

  9. PRIGo: a new multi-axis goniometer for macromolecular crystallography

    Energy Technology Data Exchange (ETDEWEB)

    Waltersperger, Sandro; Olieric, Vincent, E-mail: vincent.olieric@psi.ch; Pradervand, Claude [Paul Scherrer Institute, Villigen PSI (Switzerland); Glettig, Wayne [Centre Suisse d’Electronique et Microtechnique SA, Neuchâtel 2002 (Switzerland); Salathe, Marco; Fuchs, Martin R.; Curtin, Adrian; Wang, Xiaoqiang; Ebner, Simon; Panepucci, Ezequiel; Weinert, Tobias [Paul Scherrer Institute, Villigen PSI (Switzerland); Schulze-Briese, Clemens [Dectris Ltd, Baden 5400 (Switzerland); Wang, Meitian, E-mail: vincent.olieric@psi.ch [Paul Scherrer Institute, Villigen PSI (Switzerland)

    2015-05-09

    The design and performance of the new multi-axis goniometer PRIGo developed at the Swiss Light Source at Paul Scherrer Institute is described. The Parallel Robotics Inspired Goniometer (PRIGo) is a novel compact and high-precision goniometer providing an alternative to (mini-)kappa, traditional three-circle goniometers and Eulerian cradles used for sample reorientation in macromolecular crystallography. Based on a combination of serial and parallel kinematics, PRIGo emulates an arc. It is mounted on an air-bearing stage for rotation around ω and consists of four linear positioners working synchronously to achieve x, y, z translations and χ rotation (0–90°), followed by a ϕ stage (0–360°) for rotation around the sample holder axis. Owing to the use of piezo linear positioners and active correction, PRIGo features spheres of confusion of <1 µm, <7 µm and <10 µm for ω, χ and ϕ, respectively, and is therefore very well suited for micro-crystallography. PRIGo enables optimal strategies for both native and experimental phasing crystallographic data collection. Herein, PRIGo hardware and software, its calibration, as well as applications in macromolecular crystallography are described.

  10. General concepts of the NG-3 goniometer design and coupled electronic control system

    International Nuclear Information System (INIS)

    Elizarov, O.I.; Zhukov, G.P.; Ondrejchka, K.; Salamatin, I.M.; Khrykin, A.S.; Erzhabek, Ya.; Shimane, Ch.; Shul'ts, V.

    1984-01-01

    The system of adjustment and control by goniometer used in spectrometer for investigating neutron diffractography is briefly described. The two-stage system of angle adjustment is accepted by which the goniometer circle position is determined by the 15-bit word. It the first stage the angle is adjusted by pitches, the accuracy of which is ensured by amplying more gearing (8 bits). At the second stage the angle is adjusted in the limits of a pitch by the system of micrometer screw up to hundredth fraction of the pitch (7 bits). From the viewpoint of control the goniometer can be considered as a totality of circle rotation control systems. Each system has its own address and storage for specifying the ordinal number of a pitch and location of the microscuew. The block-diagram of the control system, the block-diagram of the goniometer coupling with controlling microprocessor and those of control program are presented

  11. Characterization of High Density Concrete by Ultrasonic Goniometer

    International Nuclear Information System (INIS)

    Suhairy Sani; Mohamad Pauzi Ismail; Noor Azreen Masenwat; Nasharuddin Isa; Mohamad Haniza Mahmud

    2014-01-01

    This paper described the results of ultrasonic goniometer measurements on concrete containing hematite. Local hematite stones were used as aggregates to produce high density concrete for application in X-and gamma shielding. Concrete cube samples (150 mm x 150 mm x 150 mm) containing hematite as coarse aggregates were prepared by changing mix ratio, water to cement ratio (w/ c) and types of fine aggregate. All samples were cured in water for 7 days. After 28 days of casting, the concrete cubes were then cut into small size of about 10 mm x 20 mm x 30 mm so that it can be fitted into goniometer specimen holder. From this measurement, longitudinal, shear and surface Rayleigh waves in the concrete can be determined. The measurement results are explained and discussed. (author)

  12. A Laboratory Goniometer System for Measuring Reflectance and Emittance Anisotropy

    Directory of Open Access Journals (Sweden)

    Arjan de Jong

    2012-12-01

    Full Text Available In this paper, a laboratory goniometer system for performing multi-angular measurements under controlled illumination conditions is described. A commercially available robotic arm enables the acquisition of a large number of measurements over the full hemisphere within a short time span making it much faster than other goniometers. In addition, the presented set-up enables assessment of anisotropic reflectance and emittance behaviour of soils, leaves and small canopies. Mounting a spectrometer enables acquisition of either hemispherical measurements or measurements in the horizontal plane. Mounting a thermal camera allows directional observations of the thermal emittance. This paper also presents three showcases of these different measurement set-ups in order to illustrate its possibilities. Finally, suggestions for applying this instrument and for future research directions are given, including linking the measured reflectance anisotropy with physically-based anisotropy models on the one hand and combining them with field goniometry measurements for joint analysis with remote sensing data on the other hand. The speed and flexibility of the system offer a large added value to the existing pool of laboratory goniometers.

  13. Installation of a four movements goniometer in the ORION detector at Ganil

    International Nuclear Information System (INIS)

    Kirsch, R.

    1997-01-01

    This technical report describes a goniometer with four degrees of freedom and its driving and remote control system (movements, motors and electronic power systems, driving of step motors). This goniometer holds a monocrystal target which is used in the ORION detector at Ganil (Caen, France) for the E257 blocking lifetime experiment. Details about the technical specifications (functioning parameters, mechanical preciseness, angular resolution, reliability, etc..) and the instructions for use (PC for motors and PC for remote control) are given. (J.S.)

  14. Evaluation of knee range of motion: Correlation between measurements using a universal goniometer and a smartphone goniometric application.

    Science.gov (United States)

    Dos Santos, Rafael Aparecido; Derhon, Viviane; Brandalize, Michelle; Brandalize, Danielle; Rossi, Luciano Pavan

    2017-07-01

    Goniometers are commonly used to measure range of motion in the musculoskeletal system. Recently smartphone goniometry applications have become available to clinicians. Compare angular measures using a universal goniometer and a smartphone application. Thirty four healthy women with at least 20° of limited range of motion regarding knee extension were recruited. Knee flexion angles of the dominant limb were measured with a universal goniometer and the ROM © goniometric application for the smartphone. Three trained examiners compared the two assessment tools. Strong correlations were found between the measures of the universal goniometer and smartphone application (Pearson's correlation and interclass correlation coefficient > 0.93). The measurements with both devices demonstrated low dispersion and little variation. Measurements obtained using the smartphone goniometric application analyzed are as reliable as those of a universal goniometer. This application is therefore a useful tool for the evaluation of knee range of motion. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Validity and test-retest reliability of manual goniometers for measuring passive hip range of motion in femoroacetabular impingement patients.

    Directory of Open Access Journals (Sweden)

    Nussbaumer Silvio

    2010-08-01

    Full Text Available Abstract Background The aims of this study were to evaluate the construct validity (known group, concurrent validity (criterion based and test-retest (intra-rater reliability of manual goniometers to measure passive hip range of motion (ROM in femoroacetabular impingement patients and healthy controls. Methods Passive hip flexion, abduction, adduction, internal and external rotation ROMs were simultaneously measured with a conventional goniometer and an electromagnetic tracking system (ETS on two different testing sessions. A total of 15 patients and 15 sex- and age-matched healthy controls participated in the study. Results The goniometer provided greater hip ROM values compared to the ETS (range 2.0-18.9 degrees; P P Conclusions The present study suggests that goniometer-based assessments considerably overestimate hip joint ROM by measuring intersegmental angles (e.g., thigh flexion on trunk for hip flexion rather than true hip ROM. It is likely that uncontrolled pelvic rotation and tilt due to difficulties in placing the goniometer properly and in performing the anatomically correct ROM contribute to the overrating of the arc of these motions. Nevertheless, conventional manual goniometers can be used with confidence for longitudinal assessments in the clinic.

  16. Contained x-ray diffraction goniometer for examination of radioactive materials

    International Nuclear Information System (INIS)

    Smith, P.K.; Osgood, B.C.; Blaser, D.E.; Howell, R.E.; Stuhler, H.; Stauver, J.

    1987-11-01

    Radioactive materials are being characterized for chemical form and certain physical properties with an x-ray diffraction goniometer customized for containment in a shielded alpha glovebox. A Siemens D500 goniometer was customized by Siemens to locate the associated electronics and x-ray generator outside the glovebox to minimize corrosion and facilitate maintenance. A graphite monochromator is used with a shielded scintillation detector to separate diffracted x-radiation from nuclear radiation. The diffraction system is computer automated for data acquisition and reduction. The facility is designed to handle primarily alpha- and beta-emitting samples with moderate neutron and gamma radiation. Samples containing plutonium, enriched uranium, and other transuranic elements are analyzed in support of site nuclear operations and development programs on nuclear waste, chemical separations, reactor fuels, and product forms

  17. Angular Dependency of Hyperspectral Measurements over Wheat Characterized by a Novel UAV Based Goniometer

    Directory of Open Access Journals (Sweden)

    Andreas Burkart

    2015-01-01

    Full Text Available In this study we present a hyperspectral flying goniometer system, based on a rotary-wing unmanned aerial vehicle (UAV equipped with a spectrometer mounted on an active gimbal. We show that this approach may be used to collect multiangular hyperspectral data over vegetated environments. The pointing and positioning accuracy are assessed using structure from motion and vary from σ = 1° to 8° in pointing and σ = 0.7 to 0.8 m in positioning. We use a wheat dataset to investigate the influence of angular effects on the NDVI, TCARI and REIP vegetation indices. Angular effects caused significant variations on the indices: NDVI = 0.83–0.95; TCARI = 0.04–0.116; REIP = 729–735 nm. Our analysis highlights the necessity to consider angular effects in optical sensors when observing vegetation. We compare the measurements of the UAV goniometer to the angular modules of the SCOPE radiative transfer model. Model and measurements are in high accordance (r2 = 0.88 in the infrared region at angles close to nadir; in contrast the comparison show discrepancies at low tilt angles (r2 = 0.25. This study demonstrates that the UAV goniometer is a promising approach for the fast and flexible assessment of angular effects.

  18. A Manual Transportable Instrument Platform for Ground-Based Spectro-Directional Observations (ManTIS and the Resultant Hyperspectral Field Goniometer System

    Directory of Open Access Journals (Sweden)

    Marcel Buchhorn

    2013-11-01

    Full Text Available This article presents and technically describes a new field spectro-goniometer system for the ground-based characterization of the surface reflectance anisotropy under natural illumination conditions developed at the Alfred Wegener Institute (AWI. The spectro-goniometer consists of a Manual Transportable Instrument platform for ground-based Spectro-directional observations (ManTIS, and a hyperspectral sensor system. The presented measurement strategy shows that the AWI ManTIS field spectro-goniometer can deliver high quality hemispherical conical reflectance factor (HCRF measurements with a pointing accuracy of ±6 cm within the constant observation center. The sampling of a ManTIS hemisphere (up to 30° viewing zenith, 360° viewing azimuth needs approx. 18 min. The developed data processing chain in combination with the software used for the semi-automatic control provides a reliable method to reduce temporal effects during the measurements. The presented visualization and analysis approaches of the HCRF data of an Arctic low growing vegetation showcase prove the high quality of spectro-goniometer measurements. The patented low-cost and lightweight ManTIS instrument platform can be customized for various research needs and is available for purchase.

  19. Fully automated laboratory and field-portable goniometer used for performing accurate and precise multiangular reflectance measurements

    Science.gov (United States)

    Harms, Justin D.; Bachmann, Charles M.; Ambeau, Brittany L.; Faulring, Jason W.; Ruiz Torres, Andres J.; Badura, Gregory; Myers, Emily

    2017-10-01

    Field-portable goniometers are created for a wide variety of applications. Many of these applications require specific types of instruments and measurement schemes and must operate in challenging environments. Therefore, designs are based on the requirements that are specific to the application. We present a field-portable goniometer that was designed for measuring the hemispherical-conical reflectance factor (HCRF) of various soils and low-growing vegetation in austere coastal and desert environments and biconical reflectance factors in laboratory settings. Unlike some goniometers, this system features a requirement for "target-plane tracking" to ensure that measurements can be collected on sloped surfaces, without compromising angular accuracy. The system also features a second upward-looking spectrometer to measure the spatially dependent incoming illumination, an integrated software package to provide full automation, an automated leveling system to ensure a standard frame of reference, a design that minimizes the obscuration due to self-shading to measure the opposition effect, and the ability to record a digital elevation model of the target region. This fully automated and highly mobile system obtains accurate and precise measurements of HCRF in a wide variety of terrain and in less time than most other systems while not sacrificing consistency or repeatability in laboratory environments.

  20. Adjustment of a goniometer for X-rays optics calibration in the spectral range 1.5-20 KeV

    International Nuclear Information System (INIS)

    Legistre, S.

    1992-10-01

    The aim of this memoir is the adjustment of a (θ, 2θ) goniometer coupled to X-rays source to calibrate mirrors (single layers like C, Ni, Au, etc... and multilayers like C/W, Si/W, etc...) in the spectral range 1.5 - 20 keV. For each kind of tested optics the adjustment of the goniometer include the procedure alignment of the different components (X-ray source, collimation slits, optics, detectors) and the first reflectivity measurements. Those measurements are compared those realized at LURE, using synchrotron radiation provided by SUPER ACO storage ring, and to a theoretical simulation

  1. An acoustic on-chip goniometer for room temperature macromolecular crystallography.

    Science.gov (United States)

    Burton, C G; Axford, D; Edwards, A M J; Gildea, R J; Morris, R H; Newton, M I; Orville, A M; Prince, M; Topham, P D; Docker, P T

    2017-12-05

    This paper describes the design, development and successful use of an on-chip goniometer for room-temperature macromolecular crystallography via acoustically induced rotations. We present for the first time a low cost, rate-tunable, acoustic actuator for gradual in-fluid sample reorientation about varying axes and its utilisation for protein structure determination on a synchrotron beamline. The device enables the efficient collection of diffraction data via a rotation method from a sample within a surface confined droplet. This method facilitates efficient macromolecular structural data acquisition in fluid environments for dynamical studies.

  2. Validity and reliability of smartphone magnetometer-based goniometer evaluation of shoulder abduction--A pilot study.

    Science.gov (United States)

    Johnson, Linda B; Sumner, Sean; Duong, Tina; Yan, Posu; Bajcsy, Ruzena; Abresch, R Ted; de Bie, Evan; Han, Jay J

    2015-12-01

    Goniometers are commonly used by physical therapists to measure range-of-motion (ROM) in the musculoskeletal system. These measurements are used to assist in diagnosis and to help monitor treatment efficacy. With newly emerging technologies, smartphone-based applications are being explored for measuring joint angles and movement. This pilot study investigates the intra- and inter-rater reliability as well as concurrent validity of a newly-developed smartphone magnetometer-based goniometer (MG) application for measuring passive shoulder abduction in both sitting and supine positions, and compare against the traditional universal goniometer (UG). This is a comparative study with repeated measurement design. Three physical therapists utilized both the smartphone MG and a traditional UG to measure various angles of passive shoulder abduction in a healthy subject, whose shoulder was positioned in eight different positions with pre-determined degree of abduction while seated or supine. Each therapist was blinded to the measured angles. Concordance correlation coefficients (CCCs), Bland-Altman plotting methods, and Analysis of Variance (ANOVA) were used for statistical analyses. Both traditional UG and smartphone MG were reliable in repeated measures of standardized joint angle positions (average CCC > 0.997) with similar variability in both measurement tools (standard deviation (SD) ± 4°). Agreement between the UG and MG measurements was greater than 0.99 in all positions. Our results show that the smartphone MG has equivalent reliability compared to the traditional UG when measuring passive shoulder abduction ROM. With concordant measures and comparable reliability to the UG, the newly developed MG application shows potential as a useful tool to assess joint angles. Published by Elsevier Ltd.

  3. A study of PC-based ultrasonic goniometer system of surface properties and characterization of materials

    Science.gov (United States)

    Sani, S.; Saad, M. H. Md; Jamaludin, N.; Ismail, M. P.; Mohd, S.; Mustapha, I.; Masenwat, N. A.; Tengku Amran, T. S.; Megat Ahmad, M. H. A.

    2018-01-01

    This paper discussed the design and development of a portable PC-based ultrasonic goniometer system that can be used to study material properties using ultrasonic wave. The system utilizes an ultrasonic pulse-receiver card model attached to computer notebook for signal display. A new specific software package (GoNIO) was developed to control the operation of the scanner, displaying the data and analyze characteristics of materials. System testing was carried out using samples with cubic dimension of about 10 mm x 20 mm x 30 mm. This size allows the sample to be fitted into the goniometer specimen holder and immersed in a liquid during measurement. The sample was rotated from incident angle of 0° to 90° during measurement and the amplitude reflected signals were recorded at every one degree of rotation. Immersion transducers were used to generate and receive the ultrasounds that pass through the samples. Longitudinal, shear and Rayleigh wave measurements were performed on the samples to determine the Dynamic Young’s Modulus. Results of measurements are explained and discussed.

  4. Reliability of a smartphone-based goniometer for knee joint goniometry.

    Science.gov (United States)

    Ferriero, Giorgio; Vercelli, Stefano; Sartorio, Francesco; Muñoz Lasa, Susana; Ilieva, Elena; Brigatti, Elisa; Ruella, Carolina; Foti, Calogero

    2013-06-01

    The aim of this study was to assess the reliability of a smartphone-based application developed for photographic-based goniometry, DrGoniometer (DrG), by comparing its measurement of the knee joint angle with that made by a universal goniometer (UG). Joint goniometry is a common mode of clinical assessment used in many disciplines, in particular in rehabilitation. One validated method is photographic-based goniometry, but the procedure is usually complex: the image has to be downloaded from the camera to a computer and then edited using dedicated software. This disadvantage may be overcome by the new generation of mobile phones (smartphones) that have computer-like functionality and an integrated digital camera. This validation study was carried out under two different controlled conditions: (i) with the participant to measure in a fixed position and (ii) with a battery of pictures to assess. In the first part, four raters performed repeated measurements with DrG and UG at different knee joint angles. Then, 10 other raters measured the knee at different flexion angles ranging 20-145° on a battery of 35 pictures taken in a clinical setting. The results showed that inter-rater and intra-rater correlations were always more than 0.958. Agreement with the UG showed a width of 18.2° [95% limits of agreement (LoA)=-7.5/+10.7°] and 14.1° (LoA=-6.6/+7.5°). In conclusion, DrG seems to be a reliable method for measuring knee joint angle. This mHealth application can be an alternative/additional method of goniometry, easier to use than other photographic-based goniometric assessments. Further studies are required to assess its reliability for the measurement of other joints.

  5. A Small Acoustic Goniometer for General Purpose Research.

    Science.gov (United States)

    Pook, Michael L; Loo, Sin Ming

    2016-04-29

    Understanding acoustic events and monitoring their occurrence is a useful aspect of many research projects. In particular, acoustic goniometry allows researchers to determine the source of an event based solely on the sound it produces. The vast majority of acoustic goniometry research projects used custom hardware targeted to the specific application under test. Unfortunately, due to the wide range of sensing applications, a flexible general purpose hardware/firmware system does not exist for this purpose. This article focuses on the development of such a system which encourages the continued exploration of general purpose hardware/firmware and lowers barriers to research in projects requiring the use of acoustic goniometry. Simulations have been employed to verify system feasibility, and a complete hardware implementation of the acoustic goniometer has been designed and field tested. The results are reported, and suggested areas for improvement and further exploration are discussed.

  6. A next generation field-portable goniometer system

    Science.gov (United States)

    Harms, Justin D.; Bachmann, Charles M.; Faulring, Jason W.; Ruiz Torres, Andres J.

    2016-05-01

    Various field portable goniometers have been designed to capture in-situ measurements of a materials bi-directional reflectance distribution function (BRDF), each with a specific scientific purpose in mind.1-4 The Rochester Institute of Technology's (RIT) Chester F. Carlson Center for Imaging Science recently created a novel instrument incorporating a wide variety of features into one compact apparatus in order to obtain very high accuracy BRDFs of short vegetation and sediments, even in undesirable conditions and austere environments. This next generation system integrates a dual-view design using two VNIR/SWIR pectroradiometers to capture target reflected radiance, as well as incoming radiance, to provide for better optical accuracy when measuring in non-ideal atmospheric conditions or when background illumination effects are non-negligible. The new, fully automated device also features a laser range finder to construct a surface roughness model of the target being measured, which enables the user to include inclination information into BRDF post-processing and further allows for roughness effects to be better studied for radiative transfer modeling. The highly portable design features automatic leveling, a precision engineered frame, and a variable measurement plane that allow for BRDF measurements on rugged, un-even terrain while still maintaining true angular measurements with respect to the target, all without sacrificing measurement speed. Despite the expanded capabilities and dual sensor suite, the system weighs less than 75 kg, which allows for excellent mobility and data collection on soft, silty clay or fine sand.

  7. A precise goniometer/tensiometer using a low cost single-board computer

    Science.gov (United States)

    Favier, Benoit; Chamakos, Nikolaos T.; Papathanasiou, Athanasios G.

    2017-12-01

    Measuring the surface tension and the Young contact angle of a droplet is extremely important for many industrial applications. Here, considering the booming interest for small and cheap but precise experimental instruments, we have constructed a low-cost contact angle goniometer/tensiometer, based on a single-board computer (Raspberry Pi). The device runs an axisymmetric drop shape analysis (ADSA) algorithm written in Python. The code, here named DropToolKit, was developed in-house. We initially present the mathematical framework of our algorithm and then we validate our software tool against other well-established ADSA packages, including the commercial ramé-hart DROPimage Advanced as well as the DropAnalysis plugin in ImageJ. After successfully testing for various combinations of liquids and solid surfaces, we concluded that our prototype device would be highly beneficial for industrial applications as well as for scientific research in wetting phenomena compared to the commercial solutions.

  8. FEM Analysis of Beam-coupling Impedance and RF Contacts Criticality on the LHC UA9 Piezo Goniometer

    CERN Document Server

    Danisi, A; Passarelli, A; Masi, A; Losito, R; Salvant, B

    2014-01-01

    The UA9 piezo-goniometer has been designed to guarantee micro-radians-accuracy angular positioning of a silicon crystal for a crystal collimation experiment in the LHC, and to minimize the impact on the LHC beam coupling impedance. This paper presents a Finite Element Method (FEM) study of the device, in both parking and operational positions, to evaluate its impact on the LHC impedance budget. In addition, the shielding contribution of the RF gaskets has been carefully evaluated, with the objective to assess the consequences for operation in case of their failure. A final word is drawn on the overall device impedance criticality.

  9. Automated spectro-goniometer: A spherical robot for the field measurement of the directional reflectance of snow

    International Nuclear Information System (INIS)

    Painter, Thomas H.; Paden, Brad; Dozier, Jeff

    2003-01-01

    We describe an automated spectro-goniometer (ASG) that rapidly measures the spectral hemispherical-directional reflectance factor (HDRF) of snow in the field across the wavelength range 0.4≤λ≤2.5 μm. Few measurements of snow's HDRF exist in the literature, in part caused by a lack of a portable instrument capable of rapid, repeatable sampling. The ASG is a two-link spherical robot coupled to a field spectroradiometer. The ASG is the first revolute joint and first automated field goniometer for use over snow and other smooth surfaces. It is light enough (∼50 kg) to be portable in a sled by an individual. The ASG samples the HDRF at arbitrary angular resolution and 0.5 Hz sampling rate. The arm attaches to the fixed-point frame 0.65 m above the surface. With vertical and oblique axes, the ASG places the sensor of the field spectroradiometer at any point on the hemisphere above a snow target. In standard usage, the ASG has the sun as the illumination source to facilitate in situ measurements over fragile surfaces not easily transported to the laboratory and to facilitate simultaneous illumination conditions for validation and calibration of satellite retrievals. The kinematics of the ASG is derived using Rodrigues' formula applied to the 2 degree-of-freedom arm. We describe the inverse kinematics for the ASG and solve the inverse problem from a given view angle to the necessary rotation about each axis. Its two-dimensional hemispheric sampling space facilitates the measurement of spectral reflectance from snow and other relatively smooth surfaces into any direction. The measurements will be used to validate radiative transfer model results of directional reflectance and to validate/calibrate directional satellite measurements of reflectance from these smooth surfaces

  10. Spectrophotometric Modeling of MAHLI Goniometer Observations

    Science.gov (United States)

    Liang, W.; Johnson, J. R.; Hayes, A.; Lemmon, M. T.; Bell, J. F., III; Grundy, W. M.; Deen, R. G.

    2017-12-01

    The Mars Hand Lends Imager (MAHLI) on the Curiosity rover's robotic arm was used as a goniometer to acquire a multiple-viewpoint data set on sol 544 [1]. Images were acquired at 20 arm positions, all centered at the same location and from a near-constant distance of 1.0 m from the surface. Although this sequence was acquired at only one time of day ( 13:30 LTST), it provided phase angle coverage from 0-110°. Images were converted to radiance from calibrated PDS files (DRXX) using radiance scaling factors and MAHLI focus position counts in an algorithm that rescaled the data to match the Mastcam M-34 calibration via comparison of sky images acquired during the mission. Converted MAHLI radiance values from an image of the Mastcam calibration target compared favorably in the red, green, and blue Bayer filters to M-34 radiance values from an image of the same target taken minutes afterwards. The 20 MAHLI images allowed construction of a digital terrain model (DTM), although images with shadows cast by the rover arm were more challenging to include. Their current absence restricts the lowest phase angles available to about 17°. The DTM enables calculation of surface normals that can be used with sky models to correct for diffuse reflectance on surface facets prior to Hapke modeling [cf. 2-6]. Regions of interest (ROIs) were extracted using one of the low emission-angle images as a template. ROI unit types included soils, light-toned surfaces (5 cm felsic rock "Nita"), dark-toned rocks with variable textures and dust cover, and larger areas representative of the average surface (see attached figure). These ROIs were translated from the template image to the other images through a matching of DTM three-dimensional coordinates. Preliminary phase curves (prior to atmospheric correction) show that soil-dominated surfaces are most backscattering, whereas rocks are least backscattering, and light-toned surfaces exhibit wavelength-dependent scattering. Future work will

  11. Measuring the eyes of trilobites: a motorized goniometer for macropaleontology

    Energy Technology Data Exchange (ETDEWEB)

    Cowen, R.; Cooper, J.H.

    1985-01-01

    The geometry of the trilobite visual surface is important in studies of trilobite taxonomy, paleoecology, and evolution. Unfortunately, methods for measuring visual surface features have been slow and laborious. The authors have built an apparatus which allows rapid, reliable measurement of angular relationships on the trilobite cephalon. A specimen is mounted on a set of turntables rotated by steeper motors driven by impulses from a computer terminal. As the turntables are rotated, their angular displacements from zero are automatically recorded to a repeatable accuracy of less than half a degree. Thus the angular positions of lens axes, spines, glabella, and other important features can be recorded directly into the computer for further processing and graphics display. The authors apparatus was designed to study the eyes of phacopid-trilobites, for two reasons. First, the Phacops rana group of trilobites is one of the type examples of punctuated speciation. Second, it has been suggested that phacopids had stereoscopic vision in each eye. The new apparatus will allow rapid and accurate study of suites of specimens, in order to test these hypotheses. Their new apparatus, essentially a motorized goniometer, could be used or modified to work with any specimens in which rapid goniometric measurements are useful. Such applications could include routine morphometric studies of molluscan or brachiopod shells or echinoderm tests, as well as specific projects dealing with spines, pores, plates, or septa in a wide variety of fossil invertebrates.

  12. Quantitative Determination of Pole Figures with a Texture Goniometer by the Reflection Method

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, Manfred

    1962-03-15

    For different slit systems of a modern texture goniometer (type Siemens) the X-ray intensity reflected from textureless plane samples has been measured as function of the tilt angle {phi} and Bragg angle {theta}. The intensity curves obtained generally enable quantitative and almost complete pole figure determinations to be made with only one reflection recording, even for materials with high line density. Investigations on rolled uranium sheet with CuK{sub {alpha}} radiation showed that for reliable chart records up to {phi} {approx} 70 deg on reflections with an angular separation of only {delta}(2{theta}) = 0.7 deg, the vertical receiving slit must be limited to at least 1 mm when using a horizontal main slit of 0.5 mm, Though in this case the intensity drop off resulting from defocusing from the flat sample surface is considerable even at small tilt angles, a correction of intensity is possible also at large angles within an accuracy of {+-} 5 %. Moreover, different pole figures for one material can be compared quantitatively, without constant slit settings and recording conditions being necessary, if the intensity values of the contour lines are always referred to the background radiation.

  13. Smartphone and Universal Goniometer for Measurement of Elbow Joint Motions: A Comparative Study

    Science.gov (United States)

    Behnoush, Behnam; Tavakoli, Nasim; Bazmi, Elham; Nateghi Fard, Fariborz; Pourgharib Shahi, Mohammad Hossein; Okazi, Arash; Mokhtari, Tahmineh

    2016-01-01

    Background Universal goniometer (UG) is commonly used as a standard method to evaluate range of motion (ROM) as part of joint motions. It has some restrictions, such as involvement of both hands of the physician, leads to instability of hands and error. Nowadays smartphones usage has been increasing due to its easy application. Objectives The study was designed to compare the smartphone inclinometer-based app and UG in evaluation of ROM of elbow. Materials and Methods The maximum ROM of elbow in position of flexion and pronation and supination of forearm were examined in 60 healthy volunteers with UG and smartphone. Data were analyzed using SPSS (ver. 16) software and appropriate statistical tests were applied, such as paired t-test, ICC and Bland Altman curves. Results The results of this study showed high reliability and validity of smartphone in regarding UG with ICC > 0.95. The highest reliability for both methods was in elbow supination and the lowest was in the elbow flexion (0.84). Conclusions Smartphones due to ease of access and usage for the physician and the patient, may be good alternatives for UG. PMID:27625754

  14. NASA's Design and Development of a Field Goniometer Instrument Using Solid Works

    Science.gov (United States)

    Turner, Mark; Sasaki, Glen; Jennings, Ernest (Technical Monitor)

    2000-01-01

    With NASA suffering severe funding cutbacks, engineers at NASA are required to produce state-of-the-art hardware with limited personnel and financial resources. In light of these constraints, the new NASA mandate is to build better, faster and cheaper. In April of 1998, Stennis Space Center's Commercial Remote Sensing Program contracted to the Systems Engineering Division at NASA Ames Research Center to develop a device known as a Field Goniometer. A Field Goniometer is a device that measures bi-directional reflectance of a target, such as vegetation, relative to the sun and an imaging system in an aircraft or spacecraft. The device is able to provide a spectral fingerprint of the surface it is measuring in wavelengths from 350nm-2500nm using a hyperspectral imager. To accomplish this project, several obstacles had to be overcome. First, the design had to be completed in less than four months. Second, due to the complexity of the design, the use of solid modeling was highly desirable but most of the group's solid modelers were assigned to other jobs. Third, the amount of funding available from the customer was one half to one third the funding typically expended for a job of this nature. Our choices for this project were to design with standard 2-D CAD systems currently used in-house or train additional engineers on our existing solids package or purchase a new solid model package. The use of a 2D CAD system was very undesirable due to the complexity of the design. Using our existing solids modeler would have required a learning curve for our engineers that would be incompatible with our schedule. Prior to this project, a member of our design group researched the solid modeling industry and decided to purchase SolidWorks. After examining the product for ease of use, modeling capability, training time required and cost, we decided our highest probability of success would be to design with Solidworks. During the design phase, our fabrication group was able to provide

  15. REFLECTANCE ANISOTROPY MEASUREMENTS USING A PUSHBROOM SPECTROMETER MOUNTED ON UAV AND A LABORATORY GONIOMETER – PRELIMINARY RESULTS

    Directory of Open Access Journals (Sweden)

    J. Suomalainen

    2015-08-01

    Full Text Available During 2014–2015 we have developed a new method to measure reflectance factor anisotropy using a pushbroom spectrometer mounted on a multicopter UAV. In this paper/presentation we describe the acquisition method and show the preliminary results of the experiment. To validate the measurements the same targets have also been measured with a laboratory goniometer system. The first experiments over sugar beet fields in 2014 show similar trends in both UAV and laboratory anisotropy data, but also some differences caused by differences in sampling and diffuse illumination. In 2015 a more extensive study on wheat, barley and potato fields were performed. The measurements were repeated on three days over the growth of the crops allowing linking the development of the crops to the anisotropy signals. On each day the anisotropy measurement was repeated 4–5 times with different solar zenith angles ranging from 60° to 40° allowing analysis how the solar angle affects the anisotropy. The first results of these experiments will be presented in this conference.

  16. Duration on the exposure control, spectra storage and texture goniometer handling in the software complex for the accumulation, control and supervising systems at the NSHR and the SKAT spectrometers (Tofa and Goni tasks)

    International Nuclear Information System (INIS)

    Kirilov, A.S.; Korobchenko, M.L.; Sirotin, A.P.; Heinitz, J.

    1997-01-01

    The VME-based accumulation, control and supervising system has been maintained at the NSHR spectrometer since March 1995. Another copy of system has been in use at the newly created SKAT spectrometer since April 1997. This paper is devoted to a detailed description of the user interface for the Join and the Tofa tasks which are dedicated to controlling the duration of the exposure, the spectra storage and handling the texture goniometer at the spectrometers. (author)

  17. Método de Cobb na escoliose idiopática do adolescente: avaliação dos ângulos obtidos com goniômetros articulados e fixos Método de Cobb en la escoliosis idiopática del adolescente: evaluación de los ángulos obtenidos con goniómetros articulados y fijos Cobb method in adolescent idiopathic scoliosis-angle: evaluation with articulated and fixed goniometers

    Directory of Open Access Journals (Sweden)

    Ana Laura Loyola Munhoz da Cunha

    2009-06-01

    ómetro articulado y con el fijo en 16 de las 17 curvas evaluadas en la presente muestra. Las diferencias observadas entre los goniómetros en la curva M parecen no estar relacionadas al equipamiento utilizado.OBJECTIVE: to determine the variance of Cobb angle measurements in adolescent idiopathic scoliosis with two types of goniometer: a fixed and an articulated one, both were previously calibrated. METHODS: eight digital radiographs of patients with adolescent idiopathic scoliosis, with severe primary curve (over 30 degrees were selected. Each one of the eight scoliosis images selected was processed 26 times and printed in a radiographic film, adding up 228 images. A total of 17 curves, primary and secondary, were measured by six orthopedic surgeons experienced in spine surgery. Each examiner received a pencil, eight scoliosis images and the same goniometer. The six orthopedists measured each curve in six different occasions, three times with the articulated and three with the fixed goniometer. The cranial and caudal vertebras to be measured were pre-established, so the choose of wrong levels could be avoided. The statistic analysis was done with "parametric tests" to determine the variance of the measures between different goniometer and the same examiner. RESULTS: among the 17 evaluated (A a Q, only the curve M showed a statistically significant difference between the angles measured by the two goniometers (mean of 33,3+9,1 degrees with the articulated and (27,9+4,2 degrees with the fixed one p=0,009. CONCLUSION: No significant differences were found between values obtained with goniometer articulated with the goniometer fixed in 16 of the 17 curves evaluated in this sample. The differences observed between the goniometer on the curve "M" does not appear to be related to the equipment used.

  18. A Compact Laboratory Spectro-Goniometer (CLabSpeG) to Assess the BRDF of Materials. Presentation, Calibration and Implementation on Fagus sylvatica L. Leaves.

    Science.gov (United States)

    Biliouris, Dimitrios; Verstraeten, Willem W; Dutré, Phillip; Van Aardt, Jan A N; Muys, Bart; Coppin, Pol

    2007-09-07

    The design and calibration of a new hyperspectral Compact Laboratory Spectro-Goniometer (CLabSpeG) is presented. CLabSpeG effectively measures the bidirectionalreflectance Factor (BRF) of a sample, using a halogen light source and an AnalyticalSpectral Devices (ASD) spectroradiometer. The apparatus collects 4356 reflectance datareadings covering the spectrum from 350 nm to 2500 nm by independent positioning of thesensor, sample holder, and light source. It has an azimuth and zenith resolution of 30 and15 degrees, respectively. CLabSpeG is used to collect BRF data and extract BidirectionalReflectance Distribution Function (BRDF) data of non-isotropic vegetation elements suchas bark, soil, and leaves. Accurate calibration has ensured robust geometric accuracy of theapparatus, correction for the conicality of the light source, while sufficient radiometricstability and repeatability between measurements are obtained. The bidirectionalreflectance data collection is automated and remotely controlled and takes approximatelytwo and half hours for a BRF measurement cycle over a full hemisphere with 125 cmradius and 2.4 minutes for a single BRF acquisition. A specific protocol for vegetative leafcollection and measurement was established in order to investigate the possibility to extractBRDF values from Fagus sylvatica L. leaves under laboratory conditions. Drying leafeffects induce a reflectance change during the BRF measurements due to the laboratorySensors 2007, 7 1847 illumination source. Therefore, the full hemisphere could not be covered with one leaf. Instead 12 BRF measurements per leaf were acquired covering all azimuth positions for a single light source zenith position. Data are collected in radiance format and reflectance is calculated by dividing the leaf cycle measurement with a radiance cycle of a Spectralon reference panel, multiplied by a Spectralon reflectance correction factor and a factor to correct for the conical effect of the light source. BRF results

  19. A Compact Laboratory Spectro-Goniometer (CLabSpeG to Assess the BRDF of Materials. Presentation, Calibration and Implementation on Fagus sylvatica L. Leaves

    Directory of Open Access Journals (Sweden)

    Pol Coppin

    2007-09-01

    Full Text Available The design and calibration of a new hyperspectral Compact Laboratory Spectro-Goniometer (CLabSpeG is presented. CLabSpeG effectively measures the bidirectionalreflectance Factor (BRF of a sample, using a halogen light source and an AnalyticalSpectral Devices (ASD spectroradiometer. The apparatus collects 4356 reflectance datareadings covering the spectrum from 350 nm to 2500 nm by independent positioning of thesensor, sample holder, and light source. It has an azimuth and zenith resolution of 30 and15 degrees, respectively. CLabSpeG is used to collect BRF data and extract BidirectionalReflectance Distribution Function (BRDF data of non-isotropic vegetation elements suchas bark, soil, and leaves. Accurate calibration has ensured robust geometric accuracy of theapparatus, correction for the conicality of the light source, while sufficient radiometricstability and repeatability between measurements are obtained. The bidirectionalreflectance data collection is automated and remotely controlled and takes approximatelytwo and half hours for a BRF measurement cycle over a full hemisphere with 125 cmradius and 2.4 minutes for a single BRF acquisition. A specific protocol for vegetative leafcollection and measurement was established in order to investigate the possibility to extractBRDF values from Fagus sylvatica L. leaves under laboratory conditions. Drying leafeffects induce a reflectance change during the BRF measurements due to the laboratorySensors 2007, 7 1847 illumination source. Therefore, the full hemisphere could not be covered with one leaf. Instead 12 BRF measurements per leaf were acquired covering all azimuth positions for a single light source zenith position. Data are collected in radiance format and reflectance is calculated by dividing the leaf cycle measurement with a radiance cycle of a Spectralon reference panel, multiplied by a Spectralon reflectance correction factor and a factor to correct for the conical effect of the light

  20. Development of BATAN’s texture diffractometer (current status)

    Energy Technology Data Exchange (ETDEWEB)

    Priyanto, T. H., E-mail: thardi@batan.go.id; Bharoto,; Mugirahardjo, H.; Muslih, R.; Ramadhani, A.; Sairun [Center for Nuclear Industrial Material Technology (PTBIN) National Nuclear Energy Agency (BATAN) Kawasan Puspiptek Serpong, Tangerang Selatan (Indonesia)

    2015-04-16

    Texture Diffractometer, called DN2, is one of neutron diffractometers in BATAN which is dedicated for texture measurement using neutron diffraction method. To obtain better performance of the DN2, a flight tube goniometer have been installed between the monochromator and sample position. By adjusting the flight tube goniometer, defocusing effect at direct beam and background effect could be reduced significantly. Some experiments have been carried out to characterize DN2 performance. The flight tube goniometer alignment and neutron wavelength calibration were characterized using silicon standard sample Si640d. Data refinement of diffraction pattern was analyzed using MAUD software and it is obtained reliability factor with background, R{sub wpb}, reduced significantly, from 42.53 % to 19.36 % after setting of flight tube goniometer. Reliability factor without background (R{sub wp}) was reduced from 27.41% to 21.36%. Calibrated of neutron wavelengh, λ = 1,2799 Angstrom is obtained.

  1. Soft X-ray diffractometer for synchrotron radiation

    CERN Document Server

    Gau, T S; Liu, K Y; Chung, C H; Chen, C K; Lai, S C; Shu, C H; Huang, Y S; Chao, C H; Lee, Y R; Chen, C T; Chang, S L

    2001-01-01

    An ultra-high vacuum soft X-ray diffractometer has been constructed and commissioned at the Synchrotron Radiation Research Center (SRRC) to investigate materials structures in mesoscale. The diffractometer, housed in a UHV tank, consists of a 6-circle goniometer, together with the systems for beam-collimation, signal detection, vacuum, and control panels. The kappa-phi (cursive,open) Greek-psi goniostat is adopted for the sample orientation. Crystal samples can be rotated along a given reciprocal lattice vector by using psi scan. Two orthogonal axes, gamma (or 2 theta) and delta, are used to move the detector. The detector is a semiconductor pin diode, which can be used in UHV ambient. This 6-circle goniometer allows for sample scanning of a wide range in the momentum space. The motors used for goniometer rotation and slit selection are UHV compatible. The UHV tank is placed on an XYZ table capable of positioning the center of the goniometer onto the incident beam. Test experiments have been carried on the 1-...

  2. The E052 - GSI Experiment, Deceleration of highly charged ions by crystal channeling. (Technical notes)

    International Nuclear Information System (INIS)

    Kirsch, R.

    2003-01-01

    The report on the E052 - GSI Experiment, devoted to 'Deceleration of highly charged ions by crystal channeling' present the technical notes and the status of this experiment in 2003. The report contains 13 sections and two annexes. The sections deal with the following issues: 1. File system of the 'PC monitor' for E052 - GSI Experiment in 2003; 2. Parameters of the 'PC monitor' file system; 3. Operation of the two PCs; 3.1. Layout of goniometer remote control; 3.2. 'PC motors' side by the beam hall; 3.3. RS232 connection cabling; 3.4. RS232 configuration on the COM1 ports of the two PCs; 4. Motor connection; 4.1. SubD-25 acquisition PC monitor arm on 'COM1'; 4.2. Motors step by step feeding side SubD-25 on 'COM1'; 4.3. Distribution of digital step by step control signals; 4.5. Upper an lower goniometer connection; 4.6. Rotation and inclination outer goniometer connection; 4.7. Ultra vacuum inner rotation and inclination connection; 5. Motor characteristics; 5.1. Upstream and downstream; 5.2. Rotation; 5.3 Inclination; 5.4. Feedings; 6. Goniometer in-beam positioning; 6.1. Height fine motor positioning; 6.2. Side manual positioning; 7. Goniometer movements; 8. Crystals and electron detection; 8.1. General layout; 8.2. 1 μm Si(100) crystal; 8.3. 33 μm Si(100) crystal; 8.4. Crystal mounting; 8.5. Electron detection; 9. Reference laser positioning of angular movements; 10. Beam track and collimators upstream the target; 11. User manual - Monitoring programme; 11.Start scanning program (GSIscan.exe); 11.2. SCANNING the crystal (Scan Control window); 11.3. MOVING THE GONIOMETER MANUALY (goniometer control window); 11.4. USING THE COUNTERS (counter display window); 11.5. MULTISCALER PLOT DISPLAY; 11.6. SELECT ACTIVE PLOT; 11.7. CURSORS; 11.8. STATISTICS; 11.9. Y SCALE change; 11.10. PLOT view and hide counter; 11.11. SAVE multiscaler spectra; 11.12. PRINT plot; 12. Simplified acquisition electronic setup; 13. The 'PC motors' software; 13.1. The code structure; 13

  3. Mobile Field Goniospectrometry

    Science.gov (United States)

    Peltoniemi, J. I.; Kaasalainen, S.; Näränen, J.

    2004-05-01

    Multiangle remote sensing needs multiangle models and multiangle ground reference data. The ground data can be measured using goniometers. Many targets are in difficult terrains and hard to bring into laboratory, which makes the ground data collection more complicated We have developed several field goniometers to measure the directional and spectral reflection signatures of various targets. The heaviest of the instruments is fully manual and very robust for field work. It can be transported using a light trailer and mounted in an hour. The new very light goniometer measures the BRDF automatically in few minutes. It can be carried by two persons even large distances to difficult places. Both of these instruments use the ASD Field Spec PRO FR spectrometer with a 4m light fibre allowing optics to be mounted up and the heavy parts down. The dimensions --- arm length about 2m --- and optics (1--8 degree view angles) limit the useful spot diameter to about 3, 10 or 30cm, making the system useful for small vegetation and soil. These two wide angle goniometers are complemented by a narrow angle backscattering goniometer utilising beamsplitters to measure up to exact backscattering direction and about 15 degree around. We present BRDF and spectra for undergrowth (lichen, moss, peat, twigs) from a field campaign in August 2003, and various grasses dry and wet. We recognise significant differences in the directional pattern between different species (factors of 2-10) and varying structural properties, making the use of directional signal for remote sensing very attractive. We are working with scattering models of snow and soil, and will continue with vegetation soon.

  4. Propagation of angular errors in two-axis rotation systems

    Science.gov (United States)

    Torrington, Geoffrey K.

    2003-10-01

    Two-Axis Rotation Systems, or "goniometers," are used in diverse applications including telescope pointing, automotive headlamp testing, and display testing. There are three basic configurations in which a goniometer can be built depending on the orientation and order of the stages. Each configuration has a governing set of equations which convert motion between the system "native" coordinates to other base systems, such as direction cosines, optical field angles, or spherical-polar coordinates. In their simplest form, these equations neglect errors present in real systems. In this paper, a statistical treatment of error source propagation is developed which uses only tolerance data, such as can be obtained from the system mechanical drawings prior to fabrication. It is shown that certain error sources are fully correctable, partially correctable, or uncorrectable, depending upon the goniometer configuration and zeroing technique. The system error budget can be described by a root-sum-of-squares technique with weighting factors describing the sensitivity of each error source. This paper tabulates weighting factors at 67% (k=1) and 95% (k=2) confidence for various levels of maximum travel for each goniometer configuration. As a practical example, this paper works through an error budget used for the procurement of a system at Sandia National Laboratories.

  5. Measuring the diffraction properties of an imaging quartz(211) crystal

    Energy Technology Data Exchange (ETDEWEB)

    Haugh, M. J.; Jacoby, K. D.; Koch, J. A. [National Security Technologies, LLC, Livermore, California 94550 (United States); Chen, H.; Schneider, M. B. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550 (United States); Hill, K. W. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States)

    2016-06-15

    A dual goniometer X-ray system was used to measure the reflectivity curve for a spherically bent quartz(211) crystal. An analysis of the dual goniometer instrument response function for the rocking curve width measurement was developed and tested against the actual measurements. The rocking curve was measured at 4510.8 eV using the Ti Kα1 characteristic spectral line. The crystal is the dispersion element for a high resolution spectrometer used for plasma studies. It was expected to have a very narrow rocking curve width. The analysis showed that we could measure the upper bound for the rocking curve width of the Qz(211) crystal. The upper bound was 58 μrad giving a lower bound for the instrument resolving power E/ΔE = 34 000. Greatly improved insight into the dual goniometer operation and its limitations was achieved.

  6. A novel ultra-high vacuum manipulator with six degrees of freedom

    International Nuclear Information System (INIS)

    Auciello, O.; Lulich, C.; Alonso, E.V.; Baragiola, R.A.

    1977-01-01

    An ultra-high vacuum goniometer of novel design for use in experiments with ion beams is described. The goniometer uses a wire system to transmit movements, is bakeable to 200 0 C and is reproducible in its angular positions to within 1.3 X 10 -4 rad (0.008 0 ). It allows a sample to be rotated around two axes over 360 0 , around a third over 180 0 , and to be translated along three perpendicular axes. (Auth.)

  7. Measurement of Shoulder Range of Motion in Patients with Adhesive Capsulitis Using a Kinect.

    Directory of Open Access Journals (Sweden)

    Seung Hak Lee

    Full Text Available Range of motion (ROM measurements are essential for the evaluation for and diagnosis of adhesive capsulitis of the shoulder (AC. However, taking these measurements using a goniometer is inconvenient and sometimes unreliable. The Kinect (Microsoft, Seattle, WA, USA is gaining attention as a new motion detecting device that is nonintrusive and easy to implement. This study aimed to apply Kinect to measure shoulder ROM in AC; we evaluated its validity by calculating the agreement of the measurements obtained using Kinect with those obtained using goniometer and assessed its utility for the diagnosis of AC. Both shoulders of 15 healthy volunteers and affected shoulders of 12 patients with AC were included in the study. The passive and active ROM of each were measured with a goniometer for flexion, abduction, and external rotation. Their active shoulder motions for each direction were again captured using Kinect and the ROM values were calculated. The agreement between the two measurements was tested with the intraclass correlation coefficient (ICC. Diagnostic performance using the Kinect ROM was evaluated with Cohen's kappa value. The cutoff values of the limited ROM were determined in the following ways: the same as passive ROM values, reflecting the mean difference, and based on receiver operating characteristic curves. The ICC for flexion/abduction/external rotation between goniometric passive ROM and the Kinect ROM were 0.906/0.942/0.911, while those between active ROMs and the Kinect ROMs were 0.864/0.932/0.925. Cohen's kappa values were 0.88, 0.88, and 1.0 with the cutoff values in the order above. Measurements of the shoulder ROM using Kinect show excellent agreement with those taken using a goniometer. These results indicate that the Kinect can be used to measure shoulder ROM and to diagnose AC as an alternative to goniometer.

  8. Validity and Reliability of 2 Goniometric Mobile Apps: Device, Application, and Examiner Factors.

    Science.gov (United States)

    Wellmon, Robert H; Gulick, Dawn T; Paterson, Mark L; Gulick, Colleen N

    2016-12-01

    Smartphones are being used in a variety of practice settings to measure joint range of motion (ROM). A number of factors can affect the validity of the measurements generated. However, there are no studies examining smartphone-based goniometer applications focusing on measurement variability and error arising from the electromechanical properties of the device being used. To examine the concurrent validity and interrater reliability of 2 goniometric mobile applications (Goniometer Records, Goniometer Pro), an inclinometer, and a universal goniometer (UG). Nonexperimental, descriptive validation study. University laboratory. 3 physical therapists having an average of 25 y of experience. Three standardized angles (acute, right, obtuse) were constructed to replicate the movement of a hinge joint in the human body. Angular changes were measured and compared across 3 raters who used 3 different devices (UG, inclinometer, and 2 goniometric apps installed on 3 different smartphones: Apple iPhone 5, LG Android, and Samsung SIII Android). Intraclass correlation coefficients (ICCs) and Bland-Altman plots were used to examine interrater reliability and concurrent validity. Interrater reliability for each of the smartphone apps, inclinometer and UG were excellent (ICC = .995-1.000). Concurrent validity was also good (ICC = .998-.999). Based on the Bland-Altman plots, the means of the differences between the devices were low (range = -0.4° to 1.2°). This study identifies the error inherent in measurement that is independent of patient factors and due to the smartphone, the installed apps, and examiner skill. Less than 2° of measurement variability was attributable to those factors alone. The data suggest that 3 smartphones with the 2 installed apps are a viable substitute for using a UG or an inclinometer when measuring angular changes that typically occur when examining ROM and demonstrate the capacity of multiple examiners to accurately use smartphone-based goniometers.

  9. International Conference on Positron Annihilation (6th) held at the University of Texas at Arlington, April 3-7, 1982. Program and Collected Abstracts.

    Science.gov (United States)

    1983-02-23

    onset of disordered vibration-rotation of the nitrate group in NaN0 3.1 It was also observed that a small change in Cq occurred at about 250 0K , 270...system consists of a goniometer and a multiscaler system. The 10-meter long goniometer and its driver and control unit has been reported previously’. The... multiscaler system consists of four sets of microprocessor-based multiscaler2 . They register signals from (1) the stationary detector, (2) the moving

  10. Five-axis goniometer for BRDF measurements

    Data.gov (United States)

    Federal Laboratory Consortium — Manufacturers are creating pigments with new and unique appearance attributes. For example, gonioapparent materials such as metallic and pearlescent coatings exhibit...

  11. Preparation of the two-body interferometry

    International Nuclear Information System (INIS)

    Tomimitsu, Hiroshi

    1995-01-01

    We are trying to develop an experimental system to detect the interference between an ordinal LLL-type interferometer and the specimen crystal. The system is composed of the monochromator, the interferometer and the specimen crystal set on each axis of a two-axis precise goniometer, and high resolution X-ray camera. Two topics are presented in the workshop: 1) the usage of the Piezo-actuators to make an ordinal goniometer much more precise, 2) an X-ray CCD camera system with the spacial-resolution of around several μm. (author)

  12. Mobile technology and telemedicine for shoulder range of motion: validation of a motion-based machine-learning software development kit.

    Science.gov (United States)

    Ramkumar, Prem N; Haeberle, Heather S; Navarro, Sergio M; Sultan, Assem A; Mont, Michael A; Ricchetti, Eric T; Schickendantz, Mark S; Iannotti, Joseph P

    2018-03-07

    Mobile technology offers the prospect of delivering high-value care with increased patient access and reduced costs. Advances in mobile health (mHealth) and telemedicine have been inhibited by the lack of interconnectivity between devices and software and inability to process consumer sensor data. The objective of this study was to preliminarily validate a motion-based machine learning software development kit (SDK) for the shoulder compared with a goniometer for 4 arcs of motion: (1) abduction, (2) forward flexion, (3) internal rotation, and (4) external rotation. A mobile application for the SDK was developed and "taught" 4 arcs of shoulder motion. Ten subjects without shoulder pain or prior shoulder surgery performed the arcs of motion for 5 repetitions. Each motion was measured by the SDK and compared with a physician-measured manual goniometer measurement. Angular differences between SDK and goniometer measurements were compared with univariate and power analyses. The comparison between the SDK and goniometer measurement detected a mean difference of less than 5° for all arcs of motion (P > .05), with a 94% chance of detecting a large effect size from a priori power analysis. Mean differences for the arcs of motion were: abduction, -3.7° ± 3.2°; forward flexion, -4.9° ± 2.5°; internal rotation, -2.4° ± 3.7°; and external rotation -2.6° ± 3.4°. The SDK has the potential to remotely substitute for a shoulder range of motion examination within 5° of goniometer measurements. An open-source motion-based SDK that can learn complex movements, including clinical shoulder range of motion, from consumer sensors offers promise for the future of mHealth, particularly in telemonitoring before and after orthopedic surgery. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  13. Wireless wearable range-of-motion sensor system for upper and lower extremity joints: a validation study.

    Science.gov (United States)

    Kumar, Yogaprakash; Yen, Shih-Cheng; Tay, Arthur; Lee, Wangwei; Gao, Fan; Zhao, Ziyi; Li, Jingze; Hon, Benjamin; Tian-Ma Xu, Tim; Cheong, Angela; Koh, Karen; Ng, Yee-Sien; Chew, Effie; Koh, Gerald

    2015-02-01

    Range-of-motion (ROM) assessment is a critical assessment tool during the rehabilitation process. The conventional approach uses the goniometer which remains the most reliable instrument but it is usually time-consuming and subject to both intra- and inter-therapist measurement errors. An automated wireless wearable sensor system for the measurement of ROM has previously been developed by the current authors. Presented is the correlation and accuracy of the automated wireless wearable sensor system against a goniometer in measuring ROM in the major joints of upper (UEs) and lower extremities (LEs) in 19 healthy subjects and 20 newly disabled inpatients through intra (same) subject comparison of ROM assessments between the sensor system against goniometer measurements by physical therapists. In healthy subjects, ROM measurements using the new sensor system were highly correlated with goniometry, with 95% of differences sensor system were also highly correlated with goniometry, with 95% of the differences being < 20° and 25° for most movements in the major joints of UE and LE, respectively.

  14. Universal crystal cooling device for precession cameras, rotation cameras and diffractometers

    International Nuclear Information System (INIS)

    Hajdu, J.; McLaughlin, P.J.; Helliwell, J.R.; Sheldon, J.; Thompson, A.W.

    1985-01-01

    A versatile crystal cooling device is described for macromolecular crystallographic applications in the 290 to 80 K temperature range. It utilizes a fluctuation-free cold-nitrogen-gas supply, an insulated Mylar crystal cooling chamber and a universal ball joint, which connects the cooling chamber to the goniometer head and the crystal. The ball joint is a novel feature over all previous designs. As a result, the device can be used on various rotation cameras, precession cameras and diffractometers. The lubrication of the interconnecting parts with graphite allows the cooling chamber to remain stationary while the crystal and goniometer rotate. The construction allows for 360 0 rotation of the crystal around the goniometer axis and permits any settings on the arcs and slides of the goniometer head (even if working at 80 K). There are no blind regions associated with the frame holding the chamber. Alternatively, the interconnecting ball joint can be tightened and fixed. This results in a set up similar to the construction described by Bartunik and Schubert where the cooling chamber rotates with the crystal. The flexibility of the systems allows for the use of the device on most cameras or diffractometers. THis device has been installed at the protein crystallographic stations of the Synchrotron Radiation Source at Daresbury Laboratory and in the Laboratory of Molecular Biophysics, Oxford. Several data sets have been collected with processing statistics typical of data collected without a cooling chamber. Tests using the full white beam of the synchrotron also look promising. (orig./BHO)

  15. The Stonehenge technique. A method for aligning coherent bremsstrahlung radiators

    International Nuclear Information System (INIS)

    Livingston, Ken

    2009-01-01

    This paper describes a technique for the alignment of crystal radiators used to produce high energy, linearly polarized photons via coherent bremsstrahlung scattering at electron beam facilities. In these experiments the crystal is mounted on a goniometer which is used to adjust its orientation relative to the electron beam. The angles and equations which relate the crystal lattice, goniometer and electron beam direction are presented here, and the method of alignment is illustrated with data taken at MAMI (the Mainz microtron). A practical guide to setting up a coherent bremsstrahlung facility and installing new crystals using this technique is also included.

  16. The Stonehenge technique. A method for aligning coherent bremsstrahlung radiators

    Energy Technology Data Exchange (ETDEWEB)

    Livingston, Ken [Department of Physics and Astronomy, University of Glasgow, Glasgow G12 8QQ (United Kingdom)], E-mail: k.livingston@physics.gla.ac.uk

    2009-05-21

    This paper describes a technique for the alignment of crystal radiators used to produce high energy, linearly polarized photons via coherent bremsstrahlung scattering at electron beam facilities. In these experiments the crystal is mounted on a goniometer which is used to adjust its orientation relative to the electron beam. The angles and equations which relate the crystal lattice, goniometer and electron beam direction are presented here, and the method of alignment is illustrated with data taken at MAMI (the Mainz microtron). A practical guide to setting up a coherent bremsstrahlung facility and installing new crystals using this technique is also included.

  17. The Stonehenge technique. A method for aligning coherent bremsstrahlung radiators

    Science.gov (United States)

    Livingston, Ken

    2009-05-01

    This paper describes a technique for the alignment of crystal radiators used to produce high energy, linearly polarized photons via coherent bremsstrahlung scattering at electron beam facilities. In these experiments the crystal is mounted on a goniometer which is used to adjust its orientation relative to the electron beam. The angles and equations which relate the crystal lattice, goniometer and electron beam direction are presented here, and the method of alignment is illustrated with data taken at MAMI (the Mainz microtron). A practical guide to setting up a coherent bremsstrahlung facility and installing new crystals using this technique is also included.

  18. Reliability of Two Smartphone Applications for Radiographic Measurements of Hallux Valgus Angles.

    Science.gov (United States)

    Mattos E Dinato, Mauro Cesar; Freitas, Marcio de Faria; Milano, Cristiano; Valloto, Elcio; Ninomiya, André Felipe; Pagnano, Rodrigo Gonçalves

    The objective of the present study was to assess the reliability of 2 smartphone applications compared with the traditional goniometer technique for measurement of radiographic angles in hallux valgus and the time required for analysis with the different methods. The radiographs of 31 patients (52 feet) with a diagnosis of hallux valgus were analyzed. Four observers, 2 with >10 years' experience in foot and ankle surgery and 2 in-training surgeons, measured the hallux valgus angle and intermetatarsal angle using a manual goniometer technique and 2 smartphone applications (Hallux Angles and iPinPoint). The interobserver and intermethod reliability were estimated using intraclass correlation coefficients (ICCs), and the time required for measurement of the angles among the 3 methods was compared using the Friedman test. A very good or good interobserver reliability was found among the 4 observers measuring the hallux valgus angle and intermetatarsal angle using the goniometer (ICC 0.913 and 0.821, respectively) and iPinPoint (ICC 0.866 and 0.638, respectively). Using the Hallux Angles application, a very good interobserver reliability was found for measurements of the hallux valgus angle (ICC 0.962) and intermetatarsal angle (ICC 0.935) only among the more experienced observers. The time required for the measurements was significantly shorter for the measurements using both smartphone applications compared with the goniometer method. One smartphone application (iPinPoint) was reliable for measurements of the hallux valgus angles by either experienced or nonexperienced observers. The use of these tools might save time in the evaluation of radiographic angles in the hallux valgus. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  19. X-ray refractometer

    International Nuclear Information System (INIS)

    Tur'yanskij, A.G.; Pirshin, I.V.

    2001-01-01

    Paper introduces a new circuit of X-ray refractometer to study angular and spectral features of refracted radiation within hard X-ray range. Refractometer incorporates two goniometers, two crystal-analyzers and three radiation detectors. The maximum distance between radiation source focal point and a receiving slit of the second goniometer is equal to 1.4 m. For the first time one obtained refraction patterns of fine-film specimens including C/Si stressed structure. Paper describes a new technique of refractometry via specimen oscillation at fixed position of a detecting device. Paper presents the measurement results of oscillation refraction patterns for specimens of melted quartz and ZnSe single crystal [ru

  20. The stonehenge technique: a new method of crystal alignment for coherent bremsstrahlung experiments

    Science.gov (United States)

    Livingston, Kenneth

    2005-08-01

    In the coherent bremsstrahlung technique a thin diamond crystal oriented correctly in an electron beam can produce photons with a high degree of linear polarization.1 The crystal is mounted on a goniometer to control its orientation and it is necessary to measure the angular offsets a) between the crystal axes and the goniometer axes and b) between the goniometer and the electron beam axis. A method for measuring these offsets and aligning the crystal was developed by Lohman et al, and has been used successfully in Mainz.2 However, recent attempts to investigate new crystals have shown that this approach has limitations which become more serious at higher beam energies where more accurate setting of the crystal angles, which scale with l/Ebeam, is required. (Eg. the recent installation of coherent bremsstrahlung facility at Jlab, with Ebeam = 6 GeV ) This paper describes a new, more general alignment technique, which overcomes these limitations. The technique is based on scans where the horizontal and vertical rotation axes of the goniometer are adjusted in a series of steps to make the normal to the crystal describe a cone of a given angle. For each step in the scan, the photon energy spectrum is measured using a tagging spectrometer, and the offsets between the electron beam and the crystal lattice are inferred from the resulting 2D plot. Using this method, it is possible to align the crystal with the beam quickly, and hence to set any desired orientation of the crystal relative to the beam. This is essential for any experiment requiring linearly polarized photons produced via coherent bremsstrahlung, and is also required for a systematic study of the channeling radiation produced by the electron beam incident on the crystal.

  1. An X-ray camera for single-crystal studies at high temperatures under controlled atmosphere

    International Nuclear Information System (INIS)

    Adlhart, W.; Tzafaras, N.; Sueno, S.; Jagodzinski, H.; Huber, H.

    1982-01-01

    A vacuum heating camera has been developed for extremely low background X-ray film work between room temperature and 2000 K. It can be used with modified conventional Weissenberg goniometers and with a specially designed focusing goniometer. The temperature control is maintained by a Pt/Pt-10% Rh thermocouple, a three-term proportional, integral and derivative (PID) controller and a programmable power supply. The accuracy in the absolute temperature setting is 10 K, the stability better than 1 K and the maximum thermal gradient over the crystal 7 K mm -1 at 1330 K. A small oxygen pressure can be applied, depending on the temperature, to control oxidation or reduction reactions of the sample. (Auth.)

  2. Automation of electron channeling investigations into crystals on the experimental stand

    International Nuclear Information System (INIS)

    Kolodin, L.G.; Kupchishin, A.A.; Bunegin, V.V.

    1995-01-01

    Automated control system of technological processes of the experimental stand is proposed for electron channeling investigation into crystals. The system is proposed for stand control automation and registration of corresponding radiations. There are four main parts in stand complex: Ehlu-6 type electron accelerator; forming and transporting system of electron beams; goniometer system; radiation detection system. Purposes of the automated system creation are following: - improvement of EhLU accelerator operating stability by of automation stabilization of its parameters; - quality improvement of electron beam monochromatization by of automation of monochromator electromagnet control; - simplification of crystal adjustment process relatively of primary electron beam and crystal transporting to the position by of goniometer automation control; - providing of automating collection and processing of data of physical experiments

  3. Reliability of the standard goniometry and diagrammatic recording of finger joint angles: a comparative study with healthy subjects and non-professional raters.

    Science.gov (United States)

    Macionis, Valdas

    2013-01-09

    Diagrammatic recording of finger joint angles by using two criss-crossed paper strips can be a quick substitute to the standard goniometry. As a preliminary step toward clinical validation of the diagrammatic technique, the current study employed healthy subjects and non-professional raters to explore whether reliability estimates of the diagrammatic goniometry are comparable with those of the standard procedure. The study included two procedurally different parts, which were replicated by assigning 24 medical students to act interchangeably as 12 subjects and 12 raters. A larger component of the study was designed to compare goniometers side-by-side in measurement of finger joint angles varying from subject to subject. In the rest of the study, the instruments were compared by parallel evaluations of joint angles similar for all subjects in a situation of simulated change of joint range of motion over time. The subjects used special guides to position the joints of their left ring finger at varying angles of flexion and extension. The obtained diagrams of joint angles were converted to numerical values by computerized measurements. The statistical approaches included calculation of appropriate intraclass correlation coefficients, standard errors of measurements, proportions of measurement differences of 5 or less degrees, and significant differences between paired observations. Reliability estimates were similar for both goniometers. Intra-rater and inter-rater intraclass correlation coefficients ranged from 0.69 to 0.93. The corresponding standard errors of measurements ranged from 2.4 to 4.9 degrees. Repeated measurements of a considerable number of raters fell within clinically non-meaningful 5 degrees of each other in proportions comparable with a criterion value of 0.95. Data collected with both instruments could be similarly interpreted in a simulated situation of change of joint range of motion over time. The paper goniometer and the standard goniometer can

  4. New optical scheme for differential measurements of diffraction reflection intensity on X-radiation sliding incidence

    International Nuclear Information System (INIS)

    Golovin, A.L.; Mas', E.T.

    1989-01-01

    An X-ray optical scheme for differential measurements of X-ray diffraction under sliding incidence conditions is proposed and an attachment design realizng this scheme, using standard equipment, is described. The main feature of the scheme is the following: collimation according to the Bragg angle is carried out for the reflected beam rather than the incident one. Goniometers can be used from DRON, TRS, GS-5 and other spectrometers. The goniometer head carrying the sample is standard, it is a part of the DRON, TRS and DTS. The crystal analyzer is fixed on the attachment. The angular position of the crystal monochromator is controlled by an inductive sensor. The experimental differential curves of X-ray diffraction under conditions of sliding incidence, taken for a silicon crystal having the 111 orientation, are given as well

  5. Use of a CCD-based area detection system of a fibre diffractometer

    International Nuclear Information System (INIS)

    Hanna, S.; Windle, A.H.

    1995-01-01

    We describe a new X-ray fibre diffractometer, consisting of a commercial X-ray sensitive video camera coupled to a conventional 3 goniometer in place of a more traditional single-point detector. The active element of the video camera is a charge-coupled device (CCD). Diffraction images, obtained at various goniometer settings, are transformed into reciprocal space, and combined to give a complete section through the origin and parallel to the symmetry axis of cylindrically averaged reciprocal space. A greater density of measurements is needed in the vicinity of the reciprocal fibre axis in order to avoid information loss due to the curvature of the Ewald sphere. The pros and cons of using CCD's as X-ray detectors are discussed and sample results from polymer fibers are shown. 17 refs., 5 figs

  6. Position controller for the arm of a neutron diffractometer using fuzzy logic

    International Nuclear Information System (INIS)

    Ayala P, G.F.

    1994-01-01

    The neutron diffractometer is an important instrument coupled to one of the radial outlets of the TRIGA-3-Salazar Reactor and is used mainly to analyze textures and crystal lattices. One of its main components is the velocity analysis goniometer which controls in a tangential way the movements of the sensor requiring for this a resolution of a hundredth of degree, but at the same time wide displacements are required. It is necessary to design and construct a system on the basis of a micro controller which control the long movements in a rapid way and with the needed accuracy. In this work, a proposition is presented: to replace the A.C. motor with a D.C. motor with a wide range of velocity and supplied with a card (DAC) to control the velocity by means of digital data. Moreover, a programmed micro controller with an algorithm based on fuzzy logic receiving data in BCD will be use. The use of micro controller will allow to set free the personal computer of the position of the goniometer; nevertheless, the system will report to the P C and its control program about the present position of the goniometer and the time when the desired position is reached. It is also consider that the user will be away from the system (a minimum of 15 meters) in order to avoid the zone with a high intensity of background radiation. (Author)

  7. Position controller for the arm of a neutron diffractometer using fuzzy logic; Controlador de posicion del brazo del difractometro de neutrones utilizando logica difusa

    Energy Technology Data Exchange (ETDEWEB)

    Ayala P, G F [Instituto Nacional de Investigaciones Nucleares, Mexico City (Mexico)

    1994-12-31

    The neutron diffractometer is an important instrument coupled to one of the radial outlets of the TRIGA-3-Salazar Reactor and is used mainly to analyze textures and crystal lattices. One of its main components is the velocity analysis goniometer which controls in a tangential way the movements of the sensor requiring for this a resolution of a hundredth of degree, but at the same time wide displacements are required. It is necessary to design and construct a system on the basis of a micro controller which control the long movements in a rapid way and with the needed accuracy. In this work, a proposition is presented: to replace the A.C. motor with a D.C. motor with a wide range of velocity and supplied with a card (DAC) to control the velocity by means of digital data. Moreover, a programmed micro controller with an algorithm based on fuzzy logic receiving data in BCD will be use. The use of micro controller will allow to set free the personal computer of the position of the goniometer; nevertheless, the system will report to the P C and its control program about the present position of the goniometer and the time when the desired position is reached. It is also consider that the user will be away from the system (a minimum of 15 meters) in order to avoid the zone with a high intensity of background radiation. (Author).

  8. Evaluation of Spectrodirectional Alfalfa Canopy Data Acquired During Daisex'99

    NARCIS (Netherlands)

    Strub, G.; Schaepman, M.E.; Knyazikhin, Y.; Itten, K.I.

    2003-01-01

    Field goniometer measurements are a tool to generate a priori bidirectional reflectance distribution function (BRDF) knowledge for correction and validation of directional reflectance data acquired by air- and spaceborne sensors. This study analyzes the diurnal hemispherical.-directional reflectance

  9. Automation of researches on direction, forming and transportation of electron beam

    International Nuclear Information System (INIS)

    Balafanov, E.K; Voronova, N.A.; Kupchishin, A.I.; Kolodin, L.G.; Grimal'skij, B.V.

    1998-01-01

    Automated control system Kristall is intended to control for technological processes of unit, for study of electrons channeling in crystals and for registration of accompanying radiation. Unit consists of 4 connected parts: EhLU-6 type electron accelerator; system for forming and transportation of electron beam; goniometer system; radiation detecting system. Aims of creation of the automated system are as follows: increase of EhLU-6 accelerator stability at the expense of automated stabilization of their parameters; increase of quality of monochromatization of electron beam; ensuring of electron miss to given point of crystal by dint of automated control for rotary electromagnet; simplification of crystal initial adjustment against initial electron beam and crystal displacement in given position at the expense automation control of goniometer; ensuring of automated gathering of information and data processing of physical experiment

  10. Introduction of neutron research facilities in Indonesia Nuclear Agency

    International Nuclear Information System (INIS)

    Nishida, Masayuki; Muslih, M. Refai; Minakawa, Nobuaki

    2004-01-01

    In this report, some facilities for neutron diffraction installed in Indonesia nuclear Agency (BATAN) are introduced. Rough sketch of BATAN, and facility arrangement in the reactor hall and the guide hall are schematically shown. The four facilities (powder diffractometer, four-circle goniometer, three-axis goniometer and neutron radiography system) are installed in the reactor hall and the three (small angle neutron scattering (SANS), high resolution SANS and high resolution powder diffractometer) in the guide hall. Neutron wavelengths determined from four hk1 planes of standard Si powder by the BATAN's neutron diffraction facility are compared with those measured by the similar facility in Japan Atomic Energy Research Institute (JAERI). The neutron diffraction profile of W-fiber reinforced Cu composite is measured by the BATAN's facility. The experimental results show the strong 110 preferred orientation to the fiber direction. (author)

  11. Micro-PIXE on thin plant tissue samples in frozen hydrated state: A novel addition to JSI nuclear microprobe

    International Nuclear Information System (INIS)

    Vavpetič, P.; Pelicon, P.; Vogel-Mikuš, K.; Grlj, N.; Pongrac, P.; Jeromel, L.; Ogrinc, N.; Regvar, M.

    2013-01-01

    Recently we completed a construction of a cryostat at Jožef Stefan Institute (JSI) nuclear microprobe enabling us to analyze various types of biological samples in frozen hydrated state using micro-PIXE/STIM/RBS. Sample load-lock system was added to our existing setup to enable us to quickly insert a sample holder with frozen hydrated tissue samples onto a cold goniometer head cooled with liquid nitrogen inside the measuring chamber. Cryotome-cut slices of frozen hydrated plant samples were mounted between two thin silicon nitride foils and then attached to the sample holder. Sufficient thermal contact between silicon nitride foils and sample holder must be achieved, as well as between the sample holder and the cold goniometer head inside the measuring chamber to prevent melting of the samples. Matrix composition of frozen hydrated tissue is consisted mostly of ice. Thinning of the sample as well as water evaporation during high vacuum and proton beam exposure was inspected by the measurements with RBS and STIM method simultaneously with micro-PIXE. For first measuring attempts a standard micro-PIXE configuration for tissue mapping was used with proton beam cross section of 1.2 × 1.2 μm 2 and a beam current of 100 pA. The temperature of the cold goniometer head was kept below 130 K throughout the entire proton beam exposure. First measurements of thin plant tissue samples in frozen hydrated state show minute sample degradation during the 10 h period of micro-PIXE measurements

  12. A new setup to measure bidirectional reflectance distribution functions

    NARCIS (Netherlands)

    Roosjen, P.P.J.; Clevers, J.G.P.W.; Bartholomeus, H.

    2012-01-01

    The Plant Facility, a new laboratory goniometer system, built by the Wageningen University has been tested in order to take bidirectional reflectance distribution function (BRDF) measurements. An ASD FieldSpec 3 spectroradiometer mounted on an industrial robot arm is able to measure small targets

  13. Evaluation of wetting ability of five new saliva substitutes on ...

    African Journals Online (AJOL)

    Methods: Two hundred & forty samples of heat-polymerized acrylic resin were fabricated using conventional method. 240 samples divided into 6 groups with 40 samples in each group. Advancing & Receding contact angles were measured using Contact Angle Goniometer & DSA4 software analysis. Results: Anova test was ...

  14. Photometric and Colorimeric Comparison of HDR and Spctrally Resolved Rendering Images

    DEFF Research Database (Denmark)

    Amdemeskel, Mekbib Wubishet; Soreze, Thierry Silvio Claude; Thorseth, Anders

    2017-01-01

    In this paper, we will demonstrate a comparison between measured colorimetric images, and simulated images from a physics based rendering engine. The colorimetric images are high dynamic range (HDR) and taken with a luminance and colour camera mounted on a goniometer. For the comparison, we have ...

  15. Channeling and Volume Reflection Based Crystal Collimation of Tevatron Circulating Beam Halo

    CERN Document Server

    Shiltsev, V.; Drozhdin, A.; Johnson, T.; Legan, A.; Mokhov, N.; Reilly, R.; Still, D.; Tesarek, R.; Zagel, J.; Peggs, S.; Assmann, R.; Previtali, V.; Scandale, W.; Chesnokov, Y.; Yazynin, I.; Guidi, V.; Ivanov, Y.

    2010-01-01

    The T980 crystal collimation experiment is underway at the Tevatron to determine if this technique could increase 980 GeV beam-halo collimation efficiency at high-energy hadron colliders such as the Tevatron and the LHC. T980 also studies various crystal types and parameters. The setup has been substantially enhanced during the Summer 2009 shutdown by installing a new O-shaped crystal in the horizontal goniometer, as well as adding a vertical goniometer with two alternating crystals (O-shaped and multi-strip) and additional beam diagnostics. First measurements with the new system are quite encouraging, with channeled and volume-reflected beams observed on the secondary collimators as predicted. Investigation of crystal collimation efficiencies with crystals in volume reflection and channeling modes are described in comparison with an amorphous primary collimator. Results on the system performance are presented for the end-of-store studies and for entire collider stores. The first investigation of colliding be...

  16. Doping effect on SILAR synthesized crystalline nanostructured Cu-doped ZnO thin films grown on indium tin oxide (ITO) coated glass substrates and its characterization

    Science.gov (United States)

    Dhaygude, H. D.; Shinde, S. K.; Velhal, Ninad B.; Takale, M. V.; Fulari, V. J.

    2016-08-01

    In the present study, a novel chemical route is used to synthesize the undoped and Cu-doped ZnO thin films in aqueous solution by successive ionic layer adsorption and reaction (SILAR) method. The synthesized thin films are characterized by x-ray diffractometer (XRD), field emission scanning electron microscopy (FE-SEM), energy dispersive x-ray analysis (EDAX), contact angle goniometer and UV-Vis spectroscopic techniques. XRD study shows that the prepared films are polycrystalline in nature with hexagonal crystal structure. The change in morphology for different doping is observed in the studies of FE-SEM. EDAX spectrum shows that the thin films consist of zinc, copper and oxygen elements. Contact angle goniometer is used to measure the contact angle between a liquid and a solid interface and after detection, the nature of the films is initiated from hydrophobic to hydrophilic. The optical band gap energy for direct allowed transition ranging between 1.60-2.91 eV is observed.

  17. Standard Methodology for Assessment of Range of Motion While Wearing Body Armor

    Science.gov (United States)

    2013-09-30

    76 STANDING STATURE (with Footwear ...Thanks also to Natick Soldier Research, Development and Engineering Center and the Soldier Integrated Protection Team and those project officers who...being fit into their best body armor size for that configuration): • Standing Stature (with footwear ) • Seated Stature At the goniometer station

  18. EFFECT OF ORTHOTICS AND FOOTWEAR ON STATIC REARFOOT KINEMATICS

    Directory of Open Access Journals (Sweden)

    Molly Winkelmeyer

    2006-09-01

    Full Text Available This study examined the effect of foot orthotics and footwear on static rearfoot kinematics. Thirty-four subjects (5 males, 29 females from physical therapy clinics and the college community gave informed consent to participate. Subject age was 42 (18 years; subject height was 1.7 (0.1 meters; subject body mass was 72.6 (12.1 kg. Markers were placed on specific sites of the lower leg and calcaneus to determine the rearfoot angle. Rearfoot angle was measured with a goniometer and digitized with video-based software (Ariel Performance Analysis System. A calcaneal mold was utilized to determine the position of the calcaneus in the shod conditions. Static rearfoot angles were measured in the following conditions: barefoot (B, barefoot with the calcaneal mold (BM, barefoot with the calcaneal mold plus the orthotic (BMO, shod with the calcaneal mold (SM, and shod with the calcaneal mold plus the orthotic (SMO. An independent t-test analyzed differences between each condition as measured with the APAS and goniometer. A one-way analysis of variance (ANOVA was utilized to determine statistically significant differences among the 5 foot conditions (p 0.05 between the APAS and goniometer measurements within each condition. One-way ANOVA showed a significant difference (p < 0.01 among the five conditions as measured by APAS. Post-hoc analysis determined that the difference between BM and SM; and the BM and SMO conditions were significantly different (p < 0.01. It was observed that the orthotic slightly decreased the amount of calcaneal eversion in the standing position. The shoes worn in the study, though neutral in construction, did significantly alter rearfoot kinematics in comparison to BM

  19. Salts and Co-crystals of Theobromine and their phase ...

    Indian Academy of Sciences (India)

    These results suggest that even though traditional salts are .... Water filtered through a double deionized purification system (AquaDM,. Bhanu, Hyderabad, India) was used in all experiments. ... vent(s) was mounted on the goniometer of Oxford .... Monoclin ic. Monoclin ic. Monoclin ic. Monoclin ic. T riclin ic. S p ace group.

  20. The passive hamstring stretch test: clinical evaluation.

    Science.gov (United States)

    Fisk, J W

    1979-03-28

    The passive hamstring stretch test is described. Using a modified goniometer it is shown that independent measurements taken by trained examiners approximate very closely to each other. This establishes the test as a valid objective measurement. The possible value of this test as a research tool in low back pain problems is discussed.

  1. Reduction of microbial biofilm formation using hydrophobic nano ...

    African Journals Online (AJOL)

    2015-04-03

    Apr 3, 2015 ... ISSN 1816-7950 (On-line) = Water SA Vol. ... nano-silica coating on cooling tower fill material. Irfan Türetgen1*. 1Istanbul University, Faculty of Science, Department of Biology, Istanbul .... The study was conducted in a 100-ℓ polypropylene lab- ... out using a contact angle goniometer with deionized water at.

  2. Investigation of the load on the lumbar region in nursing technique's movements - relation between twist and surface electromyogram.

    Science.gov (United States)

    Maekawa, Yasuko; Shiozaki, Akira; Majima, Yukie

    2009-01-01

    This study measured the twist angle of the lumbar region and the surface electromyogram (EMG) and examined their mutual relation to elucidate the degree and influence of factors of "twist" in nursing techniques as a cause of lower back pain. Using a goniometer (two-way angle and twist sensors) and an EMG(SX230; DKH Co., Ltd.), we conducted measurements by affixing the goniometer on the lumbar vertebral column and EMG sensor at four points of right and left sides of L2 and L4 (of the erector muscle of the spine). The measured nursing techniques were three common methods of "transferring a patient from bed to wheelchair," which is said to impart a heavy load on the lumbar region. Results show that the correlation value between the twist angle rate and mean energy is likely to be greater, suggesting that the magnitude of the load on the lumbar region should be related to the twist speed rather than to the twist angle of the movement itself.

  3. Smartphone Photography as a Tool to Measure Knee Range of Motion.

    Science.gov (United States)

    Mica, Megan Conti; Wagner, Eric R; Shin, Alexander Y

    2018-01-01

    The objective of this study was to validate measuring knee range of motion (ROM) from smartphone photography. Thirty-two participants (64 knees) obtained smartphone photographs of knee flexion and extension. Surgeons obtained the same photographs and goniometric measurement of ROM. ROM was measured using Adobe Photoshop. Goniometer versus digital measurements, participant versus surgeon photographs, and interobserver measurements were analyzed. The average difference in goniometer and digital photograph measurements was 5°. The interclass correlation was .642(L) and .656(R). The Bland-Altman plots demonstrated that 29/32 digital measurements were within the 95% confidence interval (CI). Participants' versus researchers' photographs averaged a 2° difference. The interclass correlation was .924(L) and .91(R). Bland-Altman plots demonstrated that 31/32 measurements were within the 95% CI. Interobserver reliability averaged aROMdifference of 5°. The concordance coefficients were .647(L) and .723(R). Bland-Altman plots demonstrated that 30 of 32 digital measurements were within the 95% CI. Measuring knee ROM using smartphone digital photography is valid and reliable. (Journal of Surgical Orthopaedic Advances 27(1):52-57, 2018).

  4. Methods for acquiring data on terrain geomorphology, course geometry and kinematics of competitors' runs in alpine skiing: a historical review.

    Science.gov (United States)

    Erdmann, Włodzimierz S; Giovanis, Vassilis; Aschenbrenner, Piotr; Kiriakis, Vaios; Suchanowski, Andrzej

    2017-01-01

    This paper aims at the description and comparison of methods of topographic analysis of racing courses at all disciplines of alpine skiing sports for the purposes of obtaining: terrain geomorphology (snowless and with snow), course geometry, and competitors' runs. The review presents specific methods and instruments according to the order of their historical appearance as follows: (1) azimuth method with the use of a compass, tape and goniometer instruments; (2) optical method with geodetic theodolite, laser and photocells; (3) triangulation method with the aid of a tape and goniometer; (4) image method with the use of video cameras; (5) differential global positioning system and carrier phase global positioning system methods. Described methods were used at homologation procedure, at training sessions, during competitions of local level and during International Ski Federation World Championships or World Cups. Some methods were used together. In order to provide detailed data on course setting and skiers' running it is recommended to analyse course geometry and kinematics data of competitors' running for all important competitions.

  5. Role of peripheral phenanthroline groups in the self-assembly of self ...

    Indian Academy of Sciences (India)

    standing and utilization of all non-covalent interac- tions including hydrogen bonding2 or π−π stacking3 .... [1b−2PF6]2+. Single crystals of 1b were obtained by slow diffusion of carbon tetrachloride into solution of ... Crystal fixed at the tip of the glass fibre was mounted on the goniometer head and was optically centered.

  6. Preferred orientation determination using line source x-ray diffraction

    International Nuclear Information System (INIS)

    Kimmel, G.; Shmarjahu, D.

    1977-10-01

    A texture goniometer has been attached to a diffractometer connected to a line-focus x-ray source. Reasonable results are obtained for the texture of rolled sheets and the test procedure is given. To illustrate the test procedure, the determination of preferred orientation in cold-rolled copper is described, as compared with random powder of sintered copper. Improvements of the measurements are proposed

  7. Microprocessor-based system for automatic X-ray diffraction and fluorescence

    International Nuclear Information System (INIS)

    Souza, A.M. de; Carmo, L.C.S. do; Pereira, V.J.E.; Soares, E.A.

    1984-01-01

    A data acquisition and processing device appropriate for X-ray analysis and goniometer control was built. The Z-80 based system as well as the whole architeture is described. The advantages and new possibilities of the automated instrument as compared to the traditional ones are listed. The X-ray diffraction and fluorescence techniques can take advantage of the automation. (Author) [pt

  8. Device for measuring the angle of repose of materials or goniometer

    Energy Technology Data Exchange (ETDEWEB)

    Depoitier, J [Institut National des Radioelements, Brussels (Belgium); Parisis, J; Rossion, R [Cimenteries CBR Cementbedrijven, Brussels (Belgium)

    1980-01-01

    The slope measuring facility consists essentially of a gamma source (Cobalt 60) positioned in front of the main position of the batter and of two scintillators (NaI crystals) opposite the source. The different absorption values piched up by the two detectors allow to determine the angle of repose of the batter. The device was especially studied for cement kilns.

  9. Further development of a facility for channeling studies: application to lattice location

    International Nuclear Information System (INIS)

    Lopes, D.R.

    1984-08-01

    Equipment modifications at the Lawrence Berkeley Laboratory (LBL) Rutherford backscattering facility, including the addition of a high precision goniometer, have been made to enhance the performance of channeling experiments. The angular divergence of the alpha particle beam was also reduced to 0 by improving the collimation. To demonstrate improved channeling capability angular scans were performed about the [100], [110], and [111] axial channels of a 3400 A (100) silicon membrane. Both the minimum yield, chi/sub min/, and the critical angle, psi/sub 1/2/, were consistent with accepted values. A preliminary investigation of the lattice location of cobalt on the (100) silicon surface was undertaken. Approximately 4.5 x 10 15 Co atoms/cm 2 were electron beam deposited on a 3900 A, HF etched silicon membrane in a system using oilless pumps. Preliminary channeling data taken approximately one month later indicated a preferred site for approximately 16% of the cobalt atoms. Channeling data obtained six months later with the new goniometer showed no evidence for a preferred site. Room temperature oxidation between experiments was observed and is thought to have affected the location of the cobalt atoms. 33 references, 15 figures

  10. Electron diffraction of CBr{sub 4} in superfluid helium droplets: A step towards single molecule diffraction

    Energy Technology Data Exchange (ETDEWEB)

    He, Yunteng; Zhang, Jie; Kong, Wei, E-mail: wei.kong@oregonstate.edu [Department of Chemistry, Oregon State University, Corvallis, Oregon 97331-4003 (United States)

    2016-07-21

    We demonstrate the practicality of electron diffraction of single molecules inside superfluid helium droplets using CBr{sub 4} as a testing case. By reducing the background from pure undoped droplets via multiple doping, with small corrections for dimers and trimers, clearly resolved diffraction rings of CBr{sub 4} similar to those of gas phase molecules can be observed. The experimental data from CBr{sub 4} doped droplets are in agreement with both theoretical calculations and with experimental results of gaseous species. The abundance of monomers and clusters in the droplet beam also qualitatively agrees with the Poisson statistics. Possible extensions of this approach to macromolecular ions will also be discussed. This result marks the first step in building a molecular goniometer using superfluid helium droplet cooling and field induced orientation. The superior cooling effect of helium droplets is ideal for field induced orientation, but the diffraction background from helium is a concern. This work addresses this background issue and identifies a possible solution. Accumulation of diffraction images only becomes meaningful when all images are produced from molecules oriented in the same direction, and hence a molecular goniometer is a crucial technology for serial diffraction of single molecules.

  11. In situ stress determination by X-ray diffractometry and its prospects

    International Nuclear Information System (INIS)

    Castex, Louis

    The mechanical behavior of the metallic construction generally relates to the amount of the residual stress which reigned in the constitutive material. It is then essential to evaluate the residual stress inside the material without destruction. The X-ray diffractometry apparatus which we have developed for this study consisted of the use of the linear sensitive detector, the special psi-goniometer and the programming computer [fr

  12. Joint angle sensors for closed-loop control

    Science.gov (United States)

    Ko, Wen H.; Miao, Chih-Lei

    In order to substitute braces that have built-in goniometers and to provide feedback signals for closed loop control of lower extremity Functional Neuromuscular System in paraplegics, a stretchable capacitive sensor was developed to accurately detect angular movement in joints. Promising clinical evaluations on the knee joints of a paraplegic and a volunteer were done. The evaluations show great promise for the possibility of implantation applications.

  13. At Home Photography-Based Method for Measuring Wrist Range of Motion.

    Science.gov (United States)

    Trehan, Samir K; Rancy, Schneider K; Johnsen, Parker H; Hillstrom, Howard J; Lee, Steve K; Wolfe, Scott W

    2017-11-01

    Purpose  To determine the reliability of wrist range of motion (WROM) measurements based on digital photographs taken by patients at home compared with traditional measurements done in the office with a goniometer. Methods  Sixty-nine postoperative patients were enrolled in this study at least 3 months postoperatively. Active and passive wrist flexion/extension and radial/ulnar deviation were recorded by one of the two attending surgeons with a 1-degree resolution goniometer at the last postoperative office visit. Patients were provided an illustrated instruction sheet detailing how to take digital photographic images at home in six wrist positions (active and passive flexion/extension, and radial/ulnar deviation). Wrist position was measured from digital images by both the attending surgeons in a randomized, blinded fashion on two separate occasions greater than 2 weeks apart using the same goniometer. Reliability analysis was performed using the intraclass correlation coefficient to assess agreement between clinical and photography-based goniometry, as well as intra- and interobserver agreement. Results  Out of 69 enrolled patients, 30 (43%) patients sent digital images. Of the 180 digital photographs, only 9 (5%) were missing or deemed inadequate for WROM measurements. Agreement between clinical and photography-based measurements was "almost perfect" for passive wrist flexion/extension and "substantial" for active wrist flexion/extension and radial/ulnar deviation. Inter- and intraobserver agreement for the attending surgeons was "almost perfect" for all measurements. Discussion  This study validates a photography-based goniometry protocol allowing accurate and reliable WROM measurements without direct physician contact. Passive WROM was more accurately measured from photographs than active WROM. This study builds on previous photography-based goniometry literature by validating a protocol in which patients or their families take and submit their own

  14. Radiographic angles in hallux valgus: differences between measurements made manually and with a computerized program.

    Science.gov (United States)

    Piqué-Vidal, Carlos; Maled-García, Ignaci; Arabi-Moreno, Juanjo; Vila, Joan

    2006-03-01

    The objective of this study was to compare angular measurements in the evaluation of hallux valgus deformities using a goniometer and a computerized program to assess degree of concordance between the two methods and determine the reliability of manual measurements. Angles measured included the hallux valgus angle (HVA), the intermetatarsal angle (IMA), the distal metatarsal articular angle (DMAA), and the proximal phalangeal articular angle (PPAA), also called the hallux valgus interphalangeus angle or interphalangeal angle. Measurements were made on preoperative weightbearing radiographs in 176 patients with symptomatic hallux valgus. Manual measurements were made with a goniometer by an orthopaedic surgeon. An independent experienced technician used digitized images to perform angular measurements with the Autocad software program (Autodesk Inc., San Rafael, CA). HVA values obtained with the two techniques were similar. However, significantly higher mean values were obtained with the Autocad for the IMA and PPAA measurements, and higher mean values were obtained for the DMAA measurement with the manual technique. Whereas differences were more or less randomly distributed for the HVA, in the remaining patients, measurements were clearly related to the measurement technique, i.e., for the DMAA, the manual technique had a tendency to show higher values, and for the IMA and PPAA the manual technique showed lower values than the computer. Correlations between both techniques for the different angular measurements were as follows: HVA, -0.179 (p = 0.018); DMMA, -0.294 (p Autocad angular measurements was excellent for the HVA (ICC = 0.89) and DMAA (ICC = 0.80) and very poor for the PPAA (ICC = 0.11) and IMA (ICC = 0.42). Angular measurements made on weightbearing radiographs with the Autocad in patients with hallux valgus deformities were more reliable than those made with a goniometer. Although for large angles, such as HVA and DMAA, results obtained with both

  15. Advanced materials analysis facility at CSIRO HIAF laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Kenny, M J; Wielunski, L S; Baxter, G R [CSIRO, Lindfield, NSW (Australia). Applied Physics Div.; Sie, S H; Suter, G F [CSIRO, North Ryde, NSW (Australia). Exploration and Mining Div.

    1994-12-31

    The HIAF facility at North Ryde, based on a 3 MV Tandetron accelerator has been operating for several years. Initially three ion sources were in operation:- conventional duoplasmatrons for proton and helium beams and a sputter ion source for heavy ions. An electrostatic focusing system was designed and built in-house for providing microbeams. The research emphasis has been largely on microbeam PIXE with particular reference to the mining industry. An AMS system was added in 1990 which prevented the inclusion of the charge exchange canal required for helium beams. The facility has been operated by CSIRO Division of Exploration and Mining. At the beginning of 1992, the lon Beam Technology Group of CSIRO Division of Applied Physics was relocated at Lindfield and became a major user of the HIAF facility. Because the research activities of this group involved Rutherford Backscattering and Channeling, it was necessary to add a helium ion source and a new high vacuum beam line incorporating a precision goniometer. These facilities became operational in the second quarter of 1992. Currently a PIXE system is being added to the chamber containing the goniometer, making the accelerator an extremely versatile one for a wide range of IBA techniques. 3 refs.

  16. A new beauty for 'ADONE': a high resolution powder diffractometer for synchrotron radiation experiments

    International Nuclear Information System (INIS)

    Burattini, E.; Simeoni, S.

    1991-01-01

    A high resolution powder diffractometer, connected to the wiggler magnet line BX1, is now operative at the Adone storage ring in Frascati. A Si channel-cut monochromator on the line allows operation in the range 1-3 A. To achieve the desired high resolution in the diffraction spectra, a 'triple-axis configuration' has been chosen: a vertical standing goniometer supports a flat Ge(111) crystal analyzer on the 2O arm. With this configuration, a value of less than 0.02 o for the FWHM of the diffraction peaks has been reached. The special design solutions adopted for a Seifer MZ VI goniometer and the microstep technology used in the stepper motor actuation assure a mechanical resolution better than 0.001 o . A special supporting table, with six degrees of freedom, has been made for the diffractometer orientation in front of the X-ray beam. An IBM-PC is dedicated to the diffractometer positioning control and preliminary data collection. As a Macintosh IICX provides for the data processing, a special software package, named 'Mac Dust', has been developed and is continuously updated. The first experimental results collected on-line during the instrument check-up are presented. (author) 5 figs., 1 tab., 11 refs

  17. Wearable textile platform for assessing stroke patient treatment in daily life conditions

    Directory of Open Access Journals (Sweden)

    Federico eLorussi

    2016-03-01

    Full Text Available Monitoring physical activities during post-stroke rehabilitation in daily life may help physicians to optimize and tailor the training program for patients. The European research project INTERACTION (FP7-ICT-2011-7-287351 evaluated motor capabilities in stroke patients during the recovery treatment period. We developed wearable sensing platform based on the sensor fusion among inertial, knitted piezoresistive sensors and textile EMG electrodes . The device was conceived in modular form and consists of a separate shirt, trousers, glove and shoe. Thanks to the novel fusion approach it has been possible to develop a model for the shoulder taking into account the scapulo-thoracic joint of the scapular girdle, considerably improving the estimation of the hand position in reaching activities. In order to minimize the sensor set used to monitor gait, a single inertial sensor fused with a textile goniometer proved to reconstruct the orientation of all the body segments of the leg. Finally, the sensing glove, endowed with three textile goniometers and three force sensors showed good capabilities in the reconstruction of grasping activities and evaluating the interaction of the hand with the environment, according to the project specifications. This paper reports on the design and the technical evaluation of the performance of the sensing platform, tested on healthy subjects.

  18. Advanced materials analysis facility at CSIRO HIAF laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Kenny, M.J.; Wielunski, L.S.; Baxter, G.R. [CSIRO, Lindfield, NSW (Australia). Applied Physics Div.; Sie, S.H.; Suter, G.F. [CSIRO, North Ryde, NSW (Australia). Exploration and Mining Div.

    1993-12-31

    The HIAF facility at North Ryde, based on a 3 MV Tandetron accelerator has been operating for several years. Initially three ion sources were in operation:- conventional duoplasmatrons for proton and helium beams and a sputter ion source for heavy ions. An electrostatic focusing system was designed and built in-house for providing microbeams. The research emphasis has been largely on microbeam PIXE with particular reference to the mining industry. An AMS system was added in 1990 which prevented the inclusion of the charge exchange canal required for helium beams. The facility has been operated by CSIRO Division of Exploration and Mining. At the beginning of 1992, the lon Beam Technology Group of CSIRO Division of Applied Physics was relocated at Lindfield and became a major user of the HIAF facility. Because the research activities of this group involved Rutherford Backscattering and Channeling, it was necessary to add a helium ion source and a new high vacuum beam line incorporating a precision goniometer. These facilities became operational in the second quarter of 1992. Currently a PIXE system is being added to the chamber containing the goniometer, making the accelerator an extremely versatile one for a wide range of IBA techniques. 3 refs.

  19. Simple microprocessor-based system for upgrading existing X-ray equipment for analysis

    International Nuclear Information System (INIS)

    Souza, A.M. de

    1986-01-01

    A data acquisition and processing device appropriate for X-ray analysis and goniometer control was built. A conventional Z-80 based systems was used, and the interfacing architeture and the applicable soft-ware are described. The advantages and new possibilities of the automated instrument as compared to previous ones are listed. It is shown that the X-ray diffraction and fluorescence techniques can take advantage of the automation using existing instruments. (Author) [pt

  20. Combined Effect of a Microporous Layer and Type I Collagen Coating on a Biphasic Calcium Phosphate Scaffold for Bone Tissue Engineering

    OpenAIRE

    Mun-Hwan Lee; Changkook You; Kyo-Han Kim

    2015-01-01

    In this study, type I collagen was coated onto unmodified and modified microporous biphasic calcium phosphate (BCP) scaffolds. Surface characterization using a scanning electron microscope (SEM) and a surface goniometer confirmed the modification of the BCP coating. The quantity of the collagen coating was investigated using Sirius Red staining, and quantitative assessment of the collagen coating showed no significant differences between the two groups. MG63 cells were used to evaluate cell p...

  1. Towards a compact and precise sample holder for macromolecular crystallography.

    Science.gov (United States)

    Papp, Gergely; Rossi, Christopher; Janocha, Robert; Sorez, Clement; Lopez-Marrero, Marcos; Astruc, Anthony; McCarthy, Andrew; Belrhali, Hassan; Bowler, Matthew W; Cipriani, Florent

    2017-10-01

    Most of the sample holders currently used in macromolecular crystallography offer limited storage density and poor initial crystal-positioning precision upon mounting on a goniometer. This has now become a limiting factor at high-throughput beamlines, where data collection can be performed in a matter of seconds. Furthermore, this lack of precision limits the potential benefits emerging from automated harvesting systems that could provide crystal-position information which would further enhance alignment at beamlines. This situation provided the motivation for the development of a compact and precise sample holder with corresponding pucks, handling tools and robotic transfer protocols. The development process included four main phases: design, prototype manufacture, testing with a robotic sample changer and validation under real conditions on a beamline. Two sample-holder designs are proposed: NewPin and miniSPINE. They share the same robot gripper and allow the storage of 36 sample holders in uni-puck footprint-style pucks, which represents 252 samples in a dry-shipping dewar commonly used in the field. The pucks are identified with human- and machine-readable codes, as well as with radio-frequency identification (RFID) tags. NewPin offers a crystal-repositioning precision of up to 10 µm but requires a specific goniometer socket. The storage density could reach 64 samples using a special puck designed for fully robotic handling. miniSPINE is less precise but uses a goniometer mount compatible with the current SPINE standard. miniSPINE is proposed for the first implementation of the new standard, since it is easier to integrate at beamlines. An upgraded version of the SPINE sample holder with a corresponding puck named SPINEplus is also proposed in order to offer a homogenous and interoperable system. The project involved several European synchrotrons and industrial companies in the fields of consumables and sample-changer robotics. Manual handling of mini

  2. Evaluation of intra-subject difference in hamstring flexibility in patients with low back pain: An exploratory study.

    Science.gov (United States)

    Radwan, Ahmed; Bigney, Kyle A; Buonomo, Haily N; Jarmak, Michael W; Moats, Shannon M; Ross, Jaimie K; Tatarevic, Enida; Tomko, Mary Anne

    2014-06-24

    To evaluate the extent of intra-subject difference in hamstring flexibility and its possible relationship to the severity of Low Back Pain (LBP). A secondary purpose was to evaluate the extent of intra-rater reliability using both electrogoniometer and conventional goniometer for measuring hamstring tightness. Potential correlations between muscle impairments and LBP may lead to more effective treatments and prevention strategies. Seventy two participants with mechanical LBP were recruited for this study. The sample included; 41 females, 31 males with a mean age of 33.69 ± (11.04) years, height of 170 ± (9) cm, and weight of 79.5 ± (1.6) kg. Hamstring length was detected indirectly using the Active Knee Extension method in the 90/90 position from supine. The amount of extension was measured using both electro-goniometer (EG)and a standard goniometer (SG). Right lower extremities of these patients were significantly more flexible than left ones at α = 0.025 (t_{72}= 3.14, p=0.002). Similarly, dominant lower extremities of these patients were significantly more flexible than the non dominant ones at α=0.025 (t _{72}=2.56, p=0.013). Additionally, Oswestry scores of the patients were significantly and positively correlated with the amount of hamstring tightness of the right lower extremities (r=0.244, p=0.039), left lower extremities (r=0.225, p=0.048) and the average of both sides (r=0.24, p=0.039). However, the Oswestry scores were negatively, but insignificantly correlated to the absolute difference between right and left extremities at (r=-0.156, p=0.091). Finally, the extent of intrasubject reliability in measuring hamstring tightness using EG and SG was found to be high (ICC=0.93).CONCLUSION: There is a possible relation between mild mechanical LBP and hamstrings tightness. It was found that the more the tightness, the higher the severity of LBP that patient experienced. Also, these patients had one of their lower extremities significantly tighter than the

  3. Ionospheric Structure and Variability on a Global Scale and Interactions with Atmosphere and Magnetosphere: Conference Proceedings of the Electromagnetic Wave Propagation Panel Symposium Held in Munich (Germany, F.R.) on 16-20 May 1988.

    Science.gov (United States)

    1989-04-01

    smail- nca le dynamics of tee poa cusp, J0. Groyhys. nlec. , 40. 4407-4414, 1985. 33.- SANIROLT, P.E. , DEEHR, G., EGELAND, A. . 156Kg, A. , VIERECK, R... cathode -ray direction finder used crossed loops, but instead of employing a goniometer, each loop was fed to one channel of a twin-channel receiver...The outputs from the receiver were applied to the orthogonal pairs of deflection plates in a special cathode -ray tube. A clean signal produces a

  4. A Gas-Spring-Loaded X-Y-Z Stage System for X-ray Microdiffraction Sample Manipulation

    International Nuclear Information System (INIS)

    Shu Deming; Cai Zhonghou; Lai, Barry

    2007-01-01

    We have designed and constructed a gas-spring-loaded x-y-z stage system for x-ray microdiffraction sample manipulation at the Advanced Photon Source XOR 2-ID-D station. The stage system includes three DC-motor-driven linear stages and a gas-spring-based heavy preloading structure, which provides antigravity forces to ensure that the stage system keeps high-positioning performance under variable goniometer orientation. Microdiffraction experiments with this new stage system showed significant sample manipulation performance improvement

  5. Combinatorial Production and Processing of Oxide Nanopowders for Transparent, Ceramic Lasers

    Science.gov (United States)

    2007-06-01

    characterized by XRD, using a Rigaku Rotating Anode Goniometer (Rigaku Denki Co. Ltd., Tokyo, Japan ), Powder samples for the Rigaku diffractometer were...NJ) were ground using an alumina mortar and pestle , with 1.0 wt% of the sample to be analyzed and packed firmly in the sample holder, leveled off at...acquired using a JEOL 4000EX (Osaka, 99+/o] were purchased from Alfa Aesar and used as received. Japan ) electron microscope operated at 400 kV. Samples

  6. Synthesis of vibroarthrographic signals in knee osteoarthritis diagnosis training.

    Science.gov (United States)

    Shieh, Chin-Shiuh; Tseng, Chin-Dar; Chang, Li-Yun; Lin, Wei-Chun; Wu, Li-Fu; Wang, Hung-Yu; Chao, Pei-Ju; Chiu, Chien-Liang; Lee, Tsair-Fwu

    2016-07-19

    Vibroarthrographic (VAG) signals are used as useful indicators of knee osteoarthritis (OA) status. The objective was to build a template database of knee crepitus sounds. Internships can practice in the template database to shorten the time of training for diagnosis of OA. A knee sound signal was obtained using an innovative stethoscope device with a goniometer. Each knee sound signal was recorded with a Kellgren-Lawrence (KL) grade. The sound signal was segmented according to the goniometer data. The signal was Fourier transformed on the correlated frequency segment. An inverse Fourier transform was performed to obtain the time-domain signal. Haar wavelet transform was then done. The median and mean of the wavelet coefficients were chosen to inverse transform the synthesized signal in each KL category. The quality of the synthesized signal was assessed by a clinician. The sample signals were evaluated using different algorithms (median and mean). The accuracy rate of the median coefficient algorithm (93 %) was better than the mean coefficient algorithm (88 %) for cross-validation by a clinician using synthesis of VAG. The artificial signal we synthesized has the potential to build a learning system for medical students, internships and para-medical personnel for the diagnosis of OA. Therefore, our method provides a feasible way to evaluate crepitus sounds that may assist in the diagnosis of knee OA.

  7. Comparison of silver and molybdenum microfocus X-ray sources for single-crystal structure determination

    OpenAIRE

    Krause, Lennard; Herbst-Irmer, Regine; Sheldrick, George M.; Stalke, Dietmar

    2015-01-01

    The quality of diffraction data obtained using silver and molybdenum microsources has been compared for six model compounds with a wide range of absorption factors. The experiments were performed on two 30 W air-cooled Incoatec IµS microfocus sources with multilayer optics mounted on a Bruker D8 goniometer with a SMART APEX II CCD detector. All data were analysed, processed and refined using standard Bruker software. The results show that Ag Kα radiation can be beneficial when heavy elements ...

  8. Intensity measurement of automotive headlamps using a photometric vision system

    Science.gov (United States)

    Patel, Balvant; Cruz, Jose; Perry, David L.; Himebaugh, Frederic G.

    1996-01-01

    Requirements for automotive head lamp luminous intensity tests are introduced. The rationale for developing a non-goniometric photometric test system is discussed. The design of the Ford photometric vision system (FPVS) is presented, including hardware, software, calibration, and system use. Directional intensity plots and regulatory test results obtained from the system are compared to corresponding results obtained from a Ford goniometric test system. Sources of error for the vision system and goniometer are discussed. Directions for new work are identified.

  9. X-ray adapter with four freedom degrees for the curvilinear surface study

    International Nuclear Information System (INIS)

    Barakhtin, B.K.; Petrov, P.P.; Moskvin, A.I.

    1989-01-01

    Four-freedom degree adapter, which is placed on goniometer of DRON X-ray diffractometer is described. The adapter consists of specimen spring holder, worm pair, which provides for specimen turning by 360 deg, as well as, of three coordination tables. Investigations of prestressed-deformed state of near-the-surface layer of curvilinear surface units and structures are carried out using X-ray diffractometer equipped with the adapter described. Determination accuracy of residual stresses at the surface of turbine vane is no worse, than ±50 MPa

  10. EXAFS measurements under high pressure conditions using a combination of a diamond anvil cell and synchrotron radiation

    International Nuclear Information System (INIS)

    Sueno, Shigeho; Nakai, Izumi; Imafuku, Masayuki; Morikawa, Hideki; Kimata, Mitsuyoshi; Ohsumi, Kazumasa; Nomura, Masaharu; Shimomura, Osamu.

    1986-01-01

    EXAFS spectra for Fe, Co, Ni K-edges were successfully measured under high pressure conditions using a combination of a set of normal 1/8 carat diamond anvils, synchrotron radiation and a scintillation counter. A newly developed motor controlled goniometer stage was used for adjusting the position of a miniature diamond anvil cell. On the measurement of Cr and Mn spectra, specially designed thinner diamond anvil was necessary. EXAFS analysis of bis(dimethylglyoximato)nickel(II) at pressures from 1 atm to 5.6 GPa was made. (author)

  11. Vibration measurements of high-heat-load monochromators for DESY PETRA III extension

    Energy Technology Data Exchange (ETDEWEB)

    Kristiansen, Paw, E-mail: paw.kristiansen@fmb-oxford.com [FMB Oxford Ltd, Unit 1 Ferry Mills, Oxford OX2 0ES (United Kingdom); Horbach, Jan; Döhrmann, Ralph; Heuer, Joachim [DESY, Deutsches Elektronen-Synchrotron Hamburg, Notkestrasse 85, 22607 Hamburg (Germany)

    2015-05-09

    Vibration measurements of a cryocooled double-crystal monochromator are presented. The origins of the vibrations are identified. The minimum achieved vibration of the relative pitch between the two crystals is 48 nrad RMS and the minimum achieved absolute vibration of the second crystal is 82 nrad RMS. The requirement for vibrational stability of beamline optics continues to evolve rapidly to comply with the demands created by the improved brilliance of the third-generation low-emittance storage rings around the world. The challenge is to quantify the performance of the instrument before it is installed at the beamline. In this article, measurement techniques are presented that directly and accurately measure (i) the relative vibration between the two crystals of a double-crystal monochromator (DCM) and (ii) the absolute vibration of the second-crystal cage of a DCM. Excluding a synchrotron beam, the measurements are conducted under in situ conditions, connected to a liquid-nitrogen cryocooler. The investigated DCM utilizes a direct-drive (no gearing) goniometer for the Bragg rotation. The main causes of the DCM vibration are found to be the servoing of the direct-drive goniometer and the flexibility in the crystal cage motion stages. It is found that the investigated DCM can offer relative pitch vibration down to 48 nrad RMS (capacitive sensors, 0–5 kHz bandwidth) and absolute pitch vibration down to 82 nrad RMS (laser interferometer, 0–50 kHz bandwidth), with the Bragg axis brake engaged.

  12. EFFECT OF MUSCLE ENERGY TECHNIQUE ON FLEXIBILITY OF HAMSTRING AND CALF MUSCLES AND SPRINTING PERFORMANCE IN SPRINTERS

    Directory of Open Access Journals (Sweden)

    M. Prasad Naik

    2015-10-01

    Full Text Available Background: Muscle energy technique is used for restoring normal tone in hypertonic muscles, strengthening weak muscles, preparing muscle for subsequent stretching, one of the main uses of this method is to normalize joint range which may help in increase flexibility and performance in sprinters. The aim of the study is to evaluate the effect of muscle energy technique on flexibility of hamstrings and calf muscles and sprinting performance in sprinters. The objective of the study is to determine the muscle energy technique on hamstrings and calf muscle flexibility and sprinting performance in sprinters by using goniometer and timing of sprinting performance. Method: The study design is an experimental study in which 30 male sprinters were recruited in this study. The study sample included all male healthy sprinters, aged between 15 -30 years. All subjects received warm up, muscle energy technique and cool down exercises daily for a period of 6weeks.The outcome measures are 90°-90°popliteal angle for assessing hamstring flexibility and ROM of ankle joint for calf muscles by universal goniometer and sprinting performance time by using stopwatch. Results: Independent t-test and paired t- test are used to analyse the data. A significant difference was found between pre and post values of hamstring and calf muscle flexibility and sprinting performance after the analysis in this study. Conclusion: This study shows that there was a significant effect of MET on hamstring and calf muscle flexibility and sprinting performance.

  13. Determination of the crystallite orientation distribution from direct pole figures

    International Nuclear Information System (INIS)

    Araujo Gomes, P.A.M. de.

    1977-01-01

    A method is described which allows to calculate the crystallite orientation distribution in polycrystalline material, from direct pole figures data of its crystallographic planes (Roe's Method). The programme was applied to (1010), (0002), (1011) and (1120) complete pole figures data for a commercial, thin sheet Zircaloy-4 tubing specimen. A semi-automatic Rigaku-Denki texture goniometer, which scans the reciprocal lattice sphere pointwise outputting the data in a punched tape, was used to obtain the pole figures. This is consistent with the results obtained through direct conclusion from the pole figures. (author)

  14. Recent progress in the chopper spectrometer, INC

    International Nuclear Information System (INIS)

    Itoh, Shinichi; Arai, Masatoshi; Kawai, Masayoshi

    2001-01-01

    A guide tube comprising supermirrors, of which the critical wavenumber is three times as large as that of natural nickel, was installed in the primary flight path of the chopper spectrometer, INC, at KENS. Also, the characteristics of the ambient-temperature H 2 O moderator, which INC is facing, was changed by renewal construction of the neutron source at KENS. We discuss here an improvement in the performance of INC by a comparison with the previous performance. We also report on the development on a goniometer for single-crystal experiments at low temperatures. (author)

  15. Investigating Knee Alignment and Foot Structure in Futsal Players with and without Hamstring Shortness

    Directory of Open Access Journals (Sweden)

    Homan Minoonejad

    2016-09-01

    Methods: In this descriptive - comparative study, 30 men athlete (18- 25 years were recruited. They were assigned into two groups of 15 subjects with and without hamstring shortness. The hamstring shortness, knee and foot alignment were respectively measured by the goniometer, the ruler and caliper. After checking the normality of the data, (with Shapiro-Wilk test independent samples t-test, were used to analyze of data at a significance level of P 0.05. Conclusion: It seems that, navicular drop is not common among athletes with hamstring shortness.

  16. Estudo comparativo do arco de movimento da coluna lombar em indivíduos praticantes e não praticantes de esporte A comparative study of lumbar range of movement in healthy athletes and non-athletes

    Directory of Open Access Journals (Sweden)

    Carla Chertman

    2010-01-01

    basis and 50 non-athletes who did not report painful symptomatology nor any symptom that could affect test performance. The measurements were made consecutively by two independent examiners by means of goniometry. The trunk flexibility and extension results were correlated to the popliteal angle and ischiotibial test, and the statistical correlation between them was analyzed. RESULTS: The average values obtained were 130.7 (101.9 for flexion and 40.2 (36.4 for extension. A significant statistical difference between the athletes and non-athletes was found in the following parameters: goniometer in flexion with examiner 1, goniometer in flexion with examiner 2 and ischiotibial test. No significant statistical differences have been found between the groups or in relation to the following parameters: goniometer in extension with examiner 1, goniometer in extension with examiner 2 and popliteal angle. CONCLUSION: Individuals who practice sports present higher values in trunk flexion than non-athletes. The use of goniometry to measure trunk amplitude showed variable measurements between examiners.

  17. NSLS-II biomedical beamlines for micro-crystallography, FMX, and for highly automated crystallography, AMX: New opportunities for advanced data collection

    Energy Technology Data Exchange (ETDEWEB)

    Fuchs, Martin R., E-mail: mfuchs@bnl.gov; Bhogadi, Dileep K.; Jakoncic, Jean; Myers, Stuart; Sweet, Robert M.; Berman, Lonny E.; Skinner, John; Idir, Mourad; Chubar, Oleg; McSweeney, Sean; Schneider, Dieter K. [National Synchrotron Light Source II, Brookhaven National Laboratory, Upton, NY 11973 (United States)

    2016-07-27

    We present the final design of the x-ray optics and experimental stations of two macromolecular crystallography (MX) beamlines at the National Synchrotron Light Source-II. The microfocusing FMX beamline will deliver a flux of ∼5×10{sup 12} ph/s at 1 Å into a 1 – 20 µm spot, its flux density surpassing current MX beamlines by up to two orders of magnitude. It covers an energy range from 5 – 30 keV. The highly automated AMX beamline is optimized for high throughput, with beam sizes from 4 – 100 µm, an energy range of 5 – 18 keV and a flux at 1 Å of ∼10{sup 13} ph/s. A focus in designing the beamlines lay on achieving high beam stability, for example by implementing a horizontal bounce double crystal monochromator at FMX. A combination of compound refractive lenses and bimorph mirror optics at FMX supports rapid beam size changes. Central components of the in-house developed experimental stations are horizontal axis goniometers with a target sphere of confusion of 100 nm, piezo-slits for dynamic beam size changes during diffraction experiments, dedicated secondary goniometers for data collection from specimen in crystallization plates, and next generation pixel array detectors. FMX and AMX will support a broad range of biomedical structure determination methods from serial crystallography on micron-sized crystals, to structure determination of complexes in large unit cells, to rapid sample screening and room temperature data collection of crystals in trays.

  18. A Pilot Study of Augmented Reality Technology Applied to the Acetabular Cup Placement During Total Hip Arthroplasty.

    Science.gov (United States)

    Ogawa, Hiroyuki; Hasegawa, Seiichirou; Tsukada, Sachiyuki; Matsubara, Masaaki

    2018-06-01

    We developed an acetabular cup placement device, the AR-HIP system, using augmented reality (AR). The AR-HIP system allows the surgeon to view an acetabular cup image superimposed in the surgical field through a smartphone. The smartphone also shows the placement angle of the acetabular cup. This preliminary study was performed to assess the accuracy of the AR-HIP system for acetabular cup placement during total hip arthroplasty (THA). We prospectively measured the placement angles using both a goniometer and AR-HIP system in 56 hips of 54 patients undergoing primary THA. We randomly determined the order of intraoperative measurement using the 2 devices. At 3 months after THA, the placement angle of the acetabular cup was measured on computed tomography images. The primary outcome was the absolute value of the difference between intraoperative and postoperative computed tomography measurements. The measurement angle using AR-HIP was significantly more accurate in terms of radiographic anteversion than that using a goniometer (2.7° vs 6.8°, respectively; mean difference 4.1°; 95% confidence interval, 3.0-5.2; P < .0001). There was no statistically significant difference in terms of radiographic inclination (2.1° vs 2.6°; mean difference 0.5°; 95% confidence interval, -1.1 to 0.1; P = .13). In this pilot study, the AR-HIP system provided more accurate information regarding acetabular cup placement angle than the conventional method. Further studies are required to confirm the utility of the AR-HIP system as a navigation tool. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. Three-dimensional rotation electron diffraction: software RED for automated data collection and data processing.

    Science.gov (United States)

    Wan, Wei; Sun, Junliang; Su, Jie; Hovmöller, Sven; Zou, Xiaodong

    2013-12-01

    Implementation of a computer program package for automated collection and processing of rotation electron diffraction (RED) data is described. The software package contains two computer programs: RED data collection and RED data processing. The RED data collection program controls the transmission electron microscope and the camera. Electron beam tilts at a fine step (0.05-0.20°) are combined with goniometer tilts at a coarse step (2.0-3.0°) around a common tilt axis, which allows a fine relative tilt to be achieved between the electron beam and the crystal in a large tilt range. An electron diffraction (ED) frame is collected at each combination of beam tilt and goniometer tilt. The RED data processing program processes three-dimensional ED data generated by the RED data collection program or by other approaches. It includes shift correction of the ED frames, peak hunting for diffraction spots in individual ED frames and identification of these diffraction spots as reflections in three dimensions. Unit-cell parameters are determined from the positions of reflections in three-dimensional reciprocal space. All reflections are indexed, and finally a list with hkl indices and intensities is output. The data processing program also includes a visualizer to view and analyse three-dimensional reciprocal lattices reconstructed from the ED frames. Details of the implementation are described. Data collection and data processing with the software RED are demonstrated using a calcined zeolite sample, silicalite-1. The structure of the calcined silicalite-1, with 72 unique atoms, could be solved from the RED data by routine direct methods.

  20. The use of workflows in the design and implementation of complex experiments in macromolecular crystallography

    International Nuclear Information System (INIS)

    Brockhauser, Sandor; Svensson, Olof; Bowler, Matthew W.; Nanao, Max; Gordon, Elspeth; Leal, Ricardo M. F.; Popov, Alexander; Gerring, Matthew; McCarthy, Andrew A.; Gotz, Andy

    2012-01-01

    A powerful and easy-to-use workflow environment has been developed at the ESRF for combining experiment control with online data analysis on synchrotron beamlines. This tool provides the possibility of automating complex experiments without the need for expertise in instrumentation control and programming, but rather by accessing defined beamline services. The automation of beam delivery, sample handling and data analysis, together with increasing photon flux, diminishing focal spot size and the appearance of fast-readout detectors on synchrotron beamlines, have changed the way that many macromolecular crystallography experiments are planned and executed. Screening for the best diffracting crystal, or even the best diffracting part of a selected crystal, has been enabled by the development of microfocus beams, precise goniometers and fast-readout detectors that all require rapid feedback from the initial processing of images in order to be effective. All of these advances require the coupling of data feedback to the experimental control system and depend on immediate online data-analysis results during the experiment. To facilitate this, a Data Analysis WorkBench (DAWB) for the flexible creation of complex automated protocols has been developed. Here, example workflows designed and implemented using DAWB are presented for enhanced multi-step crystal characterizations, experiments involving crystal reorientation with kappa goniometers, crystal-burning experiments for empirically determining the radiation sensitivity of a crystal system and the application of mesh scans to find the best location of a crystal to obtain the highest diffraction quality. Beamline users interact with the prepared workflows through a specific brick within the beamline-control GUI MXCuBE

  1. Multiaxial stress analysis taking account of penetration depth of x-rays, 3

    International Nuclear Information System (INIS)

    Yoshioka, Yasuo; Sasaki, Toshihiko; Kuramoto, Makoto.

    1985-01-01

    In the past X-ray stress analysis in which the effect of stress gradients was taken into account within the penetration depth of X-rays, three assumptions have been made; 1) the stress gradient is linear in respect to the depth from the specimen surface, 2) the penetration depth of X-ray is a function of Sin 2 PSI and 3) the strain measured by X-rays corresponds to the weighted average strain on the intensity of the diffracted X-rays. A problem, however, still remains on the assumption of the X-ray penetration depth. We sometimes observed noticiable errors in the stage of the numerical simulation and these errors depend on the combination of stress components in a stress tensor. In the present paper, we proposed a new X-ray multiaxial stress analysis without using the assumption of the X-ray penetration depth. This analysis is also applicable to both the iso-inclination method ( OHM -goniometer) and the side inclination method (PSI-goniometer). The weighted average strain by X-rays, 1 >(phi), is expressed as a 4th degree function of cosPSI for iso-inclination method and 3rd degree for side inclination method. By rearranging this function as a sum of average strain, ( 1 >(0 0 )+ 1 >(90 0 )), and difference of average strain, ( 1 >(0 0 )- 1 >(90 0 )), we can solve the stress components with sufficient accuracy by a least squares method. The validity of this method was proved through numerical simulations and experiments. (author)

  2. Experimental design for reflection measurements of highly reactive liquid or solid substances with application to liquid sodium

    International Nuclear Information System (INIS)

    Chan, S.H.; Gossler, A.A.

    1980-01-01

    A versatile goniometer system with associated electronic components and mechanical instruments has been assembled. It is designed to measure spectral, specular reflectances of highly reactive liquid or solid substances over a spectral range of 0.3 to 9 μ and incidence angles of 12 to 30 0 off the normal direction. The capability of measuring reflectances of liquid substances clearly distinguishes this experimental design from conventional systems which are applicable only to solid substances. This design has been used to measure the spectral, specular reflectance of liquid sodium and preliminary results obtained are compared with those of solid sodium measured by other investigators

  3. Establishment of a computer-controlled retroreflection measurement system at the National Metrology Institute of Turkey (UME)

    International Nuclear Information System (INIS)

    Samedov, Farhad; Celikel, Oguz; Bazkir, Ozcan

    2005-01-01

    In order to characterize photometric properties of retroreflectors, a fully automated retroreflector measurement system is designed in National Metrology Institute of Turkey (UME). The system is composed of a lighting projector, a goniometer, filter radiometers, 100 dB transimpedance amplifiers, and 24-bit resolution analog-digital converter card with a special software. The established system provides a new calibration capability to determine the luminous intensity and retroreflection coefficients of the retroreflective materials with the expanded uncertainties of 1.07% and 1.13% (k=2), respectively. The traceability in retroreflection measurements was linked to the detector-based photometric scale of UME

  4. Digital controller for stepping motor-driven X-ray diffractometer

    International Nuclear Information System (INIS)

    Naval, P.C. Jr.; Saligan, P.P.; Calix, V.B.S.

    1985-01-01

    Presented is a stepping motor controller for the Philips PW 1050 Vertical Goniometer featuring crystal-controlled scan rates of 4, 2, 1, 1/2, 1/4, 1/8, 1/16 degree per minute in the continuous scan mode, and step sizes of 0.005, 0.01, 0.02, 0.025, 0.05, 0.1, 0.2, 0.5 degree when operated in the step scan mode. A slow rate of 96 degrees per minute is provided for positioning purposes. The TTL-implemented design accomodates upgrading to higher levels of automation by a simple substitution of the control logic card. (Auth.)

  5. ANALYSIS ON THE VARIATION OF MEDIAL ROTATION VALUES ACCORDING TO THE POSITION OF THE HUMERAL DIAPHYSIS.

    Science.gov (United States)

    Miyazaki, Alberto Naoki; Fregoneze, Marcelo; Santos, Pedro Doneux; da Silva, Luciana Andrade; do Val Sella, Guilherme; Cohen, Carina; Busin Giora, Taís Stedile; Checchia, Sergio Luiz; Raia, Fabio; Pekelman, Hélio; Cymrot, Raquel

    2012-01-01

    To analyze the validity of measurements of medial rotation (MR) of the shoulder, using vertebral levels, according to the variation in the position of the humeral diaphysis, and to test the bi-goniometer as a new measuring instrument. 140 shoulders (70 patients) were prospectively evaluated in cases presenting unilateral shoulder MR limitation. The vertebral level was evaluated by means of a visual scale and was correlated with the angle obtained according to the position of the humeral diaphysis, using the bi-goniometer developed with the Department of Mechanical Engineering of Mackenzie University. The maximum vertebral level reached through MR on the unaffected side ranged from T3 to T12, and on the affected side, from T6 to the trochanter. Repositioning of the affected limb in MR according to the angular values on the normal side showed that 57.13% of the patients reached lower levels, between the sacrum, gluteus and trochanter. From analysis on the maximum vertebral level attained and the variation between the affected angle x (frontal plane: abduction and MR of the shoulder) and the unaffected angle x in MR, we observed that the greater the angle of the diaphyseal axis was, the lower the variation in the vertebral level attained was. From evaluating the linear correlation between the variables of difference in maximum vertebral level reached and variation in the affected angle y (extension and abduction of the shoulder) and the unaffected angle y in MR, we observed that there was no well-established linear relationship between these variables. Measurement of MR using vertebral levels does not correspond to the real values, since it varies according to the positioning of the humeral diaphysis.

  6. Protein crystallography with a micrometre-sized synchrotron-radiation beam

    International Nuclear Information System (INIS)

    Moukhametzianov, Rouslan; Burghammer, Manfred; Edwards, Patricia C.; Petitdemange, Sebastien; Popov, Dimitri; Fransen, Maikel; McMullan, Gregory; Schertler, Gebhard F. X.; Riekel, Christian

    2008-01-01

    For the first time, protein microcrystallography has been performed with a focused synchrotron-radiation beam of 1 µm using a goniometer with a sub-micrometre sphere of confusion. The crystal structure of xylanase II has been determined with a flux density of about 3 × 10 10 photons s −1 µm −2 at the sample. For the first time, protein microcrystallography has been performed with a focused synchrotron-radiation beam of 1 µm using a goniometer with a sub-micrometre sphere of confusion. The crystal structure of xylanase II has been determined with a flux density of about 3 × 10 10 photons s −1 µm −2 at the sample. Two sets of diffraction images collected from different sized crystals were shown to comprise data of good quality, which allowed a 1.5 Å resolution xylanase II structure to be obtained. The main conclusion of this experiment is that a high-resolution diffraction pattern can be obtained from 20 µm 3 crystal volume, corresponding to about 2 × 10 8 unit cells. Despite the high irradiation dose in this case, it was possible to obtain an excellent high-resolution map and it could be concluded from the individual atomic B-factor patterns that there was no evidence of significant radiation damage. The photoelectron escape from a narrow diffraction channel is a possible reason for reduced radiation damage as indicated by Monte Carlo simulations. These results open many new opportunities in scanning protein microcrystallography and make random data collection from microcrystals a real possibility, therefore enabling structures to be solved from much smaller crystals than previously anticipated as long as the crystallites are well ordered

  7. Evaluation of the pole figure

    International Nuclear Information System (INIS)

    Cabrera B, E.; Macias B, L.R.

    1984-01-01

    In the present work it's shown the possibility of obtaining a pole-figure from the data generated in a conventional X-ray equipment, with a commercial goniometer and no electronic device to process the data. The way to plot the pole-figure on-line is by means of measuring the diffractogram and plot manually the stereographic projections. The atainable precision is very low in such a cumbersome process. In this paper we substitute such method by storing the data in a punched tape from a conventional teletype. The data is processed in a computer and the pole-figure is recorded by a plotter attached to the computer. (author)

  8. Channeling experiments at IPNE Cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Constantin, F; Dumitru, M; Ivan, A [Cyclotron Laboratory, Institute of Atomic Physics, Institute of Physics and Nuclear Engineering, R-76900 Bucharest, P.O.Box MG-6, (Romania)

    1992-01-01

    Channeling experiments have been performed at the I.P.N.E Cyclotron using a 3 MeV alpha beam. A slide system cut the beam up to 5 minutes spatial resolution with a maximum 60 nA beam current on the target. The two-axis goniometer, fully computer-controlled, moves the target, a silicon wafer, with 2.5 minute resolution, while an alpha particle sensitive solid state detector, monitors the backscattered particle fluence. In the first stage, channeling appears to be a simple, fast and reliable method for precise monocrystal orientation. A reduction of the host yield by a factor of two allowed impurities and defects to be studied. (Author).

  9. REPRODUCIBILITY AND EQUIVALENCE OF COBBMETER APPLICATION IN THE SAGITTAL EVALUATION OF THE SPINE

    Directory of Open Access Journals (Sweden)

    Luis Marchi

    Full Text Available ABSTRACT Objective: This study aims to evaluate the reliability and equivalency of using the Cobbmeter application for iPhone compared to the manual measurement method in the analysis of the sagittal spinal alignment. Methods: Cross-sectional, prospective, single-center study that had 20 panoramic radiographs of the spine in lateral view, in a neutral standing position, analyzed blindly and randomly by three independent examiners in three different times. The parameters were pelvic incidence (PI, pelvic tilt (PT and lumbar lordosis (LL. The statistical analysis was performed to measure the intraclass correlation coefficient (ICC between the two measurement methods, in addition to measuring the intra and inter-evaluators reliability. Results: For reproducibility analysis, the intra-evaluators ICC using the application resulted in a Kappa (K of 0.975 for the evaluation of pelvic incidence (PI evaluation. For pelvic tilt (PT, the K value obtained was 0.981 and the K measured for lumbar lordosis (LL analysis was 0.987. The inter-evaluators evaluation of reproducibility using the application resulted in a K value of 0.917 for PI, 0.930 for PT and 0.951 for LL. For the assessment of equivalency of methods, comparing the application to the standard method, with a goniometer and dermographic pencil, the K value found for PI was 0.873, for PV was 0.939 and for LL was 0.914. All values were significant (p<0.001 against the null hypothesis. Conclusion: This smartphone application is a valid and reliable instrument for measuring the angle involved in the sagittal balance of the spine. Furthermore, the results show that its applicability is not inferior to the manual method with goniometer and dermographic pencil.

  10. A new attempt of measurement film thickness by x-ray diffractometry

    International Nuclear Information System (INIS)

    Kosaka, Masao; Kobayashi, Hideo

    1987-01-01

    In order to make film thickness measurements independent from the property or the structure of the film materials or the substrate, it is needed to adopt instead of directly utilizing the X-ray diffraction intensity, or attenuation information obtained from the substrate or film material, other new methods for measurement. Among the information obtained by X-ray diffraction, if intensity is excluded, others are F.W.H.M. and diffraction angle, only. If it is possible to investigate the film thickness dependency of the diffraction angle, it should be possible to measure the film thickness by diffraction angle. However, since diffraction angle has no film thickness dependency, it cannot be used directly for measurement. However, if we consider the principle of the X-ray diffractometer method, although it may be very slight, the substrate will be eccentric from the revolving center of the goniometer on account of the thickness of the film. If eccentricity occurs, this will cause changes in the diffraction angle. If we set the radius of the goniometer as R, diffraction angle θ, and the eccentricity from the revolving center of the specimen surface X, the deflection angle Δ2θ of 2θ may be expressed by Δ2θ = -2X · COSθ/R Thus, if X is caused by the film thickness, and by measuring the Δ2θ, it will be possible to measure the film thickness. As a result of the experiment, it was found that X-ray diffraction method can be used for the measurement of the film thickness of a few microns or above by utilizing the eccentricity caused by the film thickness. Especially it has the advantage of being able to measure thick films that X-rays will not penetrate, without being influenced by the chemical structure of the film or the substrates. (author)

  11. Statistical Validation for Clinical Measures: Repeatability and Agreement of Kinect™-Based Software.

    Science.gov (United States)

    Lopez, Natalia; Perez, Elisa; Tello, Emanuel; Rodrigo, Alejandro; Valentinuzzi, Max E

    2018-01-01

    The rehabilitation process is a fundamental stage for recovery of people's capabilities. However, the evaluation of the process is performed by physiatrists and medical doctors, mostly based on their observations, that is, a subjective appreciation of the patient's evolution. This paper proposes a tracking platform of the movement made by an individual's upper limb using Kinect sensor(s) to be applied for the patient during the rehabilitation process. The main contribution is the development of quantifying software and the statistical validation of its performance, repeatability, and clinical use in the rehabilitation process. The software determines joint angles and upper limb trajectories for the construction of a specific rehabilitation protocol and quantifies the treatment evolution. In turn, the information is presented via a graphical interface that allows the recording, storage, and report of the patient's data. For clinical purposes, the software information is statistically validated with three different methodologies, comparing the measures with a goniometer in terms of agreement and repeatability. The agreement of joint angles measured with the proposed software and goniometer is evaluated with Bland-Altman plots; all measurements fell well within the limits of agreement, meaning interchangeability of both techniques. Additionally, the results of Bland-Altman analysis of repeatability show 95% confidence. Finally, the physiotherapists' qualitative assessment shows encouraging results for the clinical use. The main conclusion is that the software is capable of offering a clinical history of the patient and is useful for quantification of the rehabilitation success. The simplicity, low cost, and visualization possibilities enhance the use of the software Kinect for rehabilitation and other applications, and the expert's opinion endorses the choice of our approach for clinical practice. Comparison of the new measurement technique with established

  12. The CJOrtho app: A mobile clinical and educational tool for orthopedics.

    Science.gov (United States)

    Reina, N; Cognault, J; Ollivier, M; Dagneaux, L; Gauci, M-O; Pailhé, R

    2018-04-11

    The need for modern patient evaluation tools continues to grow. A dependable and reproducible assessment provides objective follow-up and increases the validity of collected data. This is where mobile apps come into play, as they provide a link between surgeons and patients. They also open the possibility of interacting with other healthcare staff to exchange common scientific reference systems and databases. The CJOrtho app provides fast access to 65 classification systems in orthopedics or trauma surgery, 20 clinical outcome scores and a digital goniometer. The development of free mobile apps is an opportunity for education and better follow-up, while meeting the demands of patients. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  13. XRD alignment, calibration and performance

    International Nuclear Information System (INIS)

    Davy, L.

    2002-01-01

    Full text: The quality of any diffractometer system is very much dependent on the alignment, calibration and performance. The three subjects are very much related. Firstly, you must know how to carry out the full diffractometer alignment. XRD alignment is easy once you know how. The presentation will show you step by step to carry out the full alignment. Secondly, you need to know how to calibrate the diffractometer system. The presentation will show you how to calibrate the goniometer, detector etc. Thirdly, to prove the system is working within the manufacturer specification. The presentation will show you how to carry out the resolution, reproducibility and linearity test. Copyright (2002) Australian X-ray Analytical Association Inc

  14. Restoring Bladder Function by Spinal Cord Neuromodulation in SCI

    Science.gov (United States)

    2015-10-01

    recumbent and legs positioned to extend beyond the edge of a cushioned bench. The legs will be supported at the knees and  ankles  with swings that...electromyographic (EMG) signals from the muscles and goniometers attached at the hip knee and  ankle  to record joint angles. Duration: 45­75 minutes...2009). Because there are no universal markers of Ia interneurons, all Ia interneurons cannot be accounted for, leaving the physiologic properties

  15. Determination of the zero in the Two theta angle and the wavelength in the neutron diffractometer for the Cyber computer of the ININ and for the IBM compatible microcomputers; Determinacion del cero en el angulo Dos teta y la longitud de onda en el difractometro de neutrones para la computadora Cyber del ININ y para microcomputadoras compatibles con IBM

    Energy Technology Data Exchange (ETDEWEB)

    Macias B, L R

    1991-05-15

    The objective of this work consists on determining the calibration in the angular parameters and the neutron wavelength used in the neutron diffractometer of the TRIGA Mark III reactor, through some readings in that a well-known sample is used by means of a Fortran computer program that is used in the CYBER computer of the ININ in Mexico, and/or in micro computers compatible with IBM. The program was also designed to determine the zero of the 2 {theta} angle of the goniometer of the diffractometer. The generated data were proven by means of well-known data of the Powder Diffraction File of the Joint Committee on Powder Diffraction Standards (JCPDS). (Author)

  16. Proton beam micromachined buried microchannels in negative tone resist materials

    International Nuclear Information System (INIS)

    Rajta, I.; Chatzichristidi, M.; Baradacs, E.; Cserhati, C.; Raptis, I.; Manoli, K.; Valamontes, E.S.

    2007-01-01

    In the present work the Atomki, Debrecen microprobe facility has been used to write long tilted structures by 2 MeV protons. For the formation of the structures, two exposures have been carried out at +20 o and -20 o using a goniometer stage sample holder. The tilted structures were resolved in the negative tone resist materials SU-8 and ADEPR (an aqueous base developable chemically amplified resist). The length of the microchannels was varied between 100 μm and 1000 μm, the wall thickness was less than 10 μm. By applying the developed methodology it was possible to resolve the desired layout through the whole length of the channel

  17. Determination of the zero in the Two theta angle and the wavelength in the neutron diffractometer for the Cyber computer of the ININ and for the IBM compatible microcomputers

    International Nuclear Information System (INIS)

    Macias B, L.R.

    1991-05-01

    The objective of this work consists on determining the calibration in the angular parameters and the neutron wavelength used in the neutron diffractometer of the TRIGA Mark III reactor, through some readings in that a well-known sample is used by means of a Fortran computer program that is used in the CYBER computer of the ININ in Mexico, and/or in micro computers compatible with IBM. The program was also designed to determine the zero of the 2 θ angle of the goniometer of the diffractometer. The generated data were proven by means of well-known data of the Powder Diffraction File of the Joint Committee on Powder Diffraction Standards (JCPDS). (Author)

  18. The concurrent validity and reliability of the Leg Motion system for measuring ankle dorsiflexion range of motion in older adults

    Directory of Open Access Journals (Sweden)

    Carlos Romero Morales

    2017-01-01

    Full Text Available Background New reliable devices for range of motion (ROM measures in older adults are necessary to improve knowledge about the functional capability in this population. Dorsiflexion ROM limitation is associated with ankle injuries, foot pain, lower limb disorders, loss of balance, gait control disorders and fall risk in older adults. The aim of the present study was to assess the validity and reliability of the Leg Motion device for measuring ankle dorsiflexion ROM in older adults. Methods Adescriptive repeated-measures study was designed to test the reliability of Leg Motion in thirty-three healthy elderly patients older than 65 years. The subjects had to meet the following inclusion and exclusion criteria in their medical records: older than 65 years; no lower extremity injury for at least one year prior to evaluation (meniscopathy, or fractures and any chronic injuries (e.g., osteoarthritis; no previous hip, knee or ankle surgery; no neuropathic alterations and no cognitive conditions (e.g., Alzheimer’s disease or dementia. Participants were recruited through the person responsible for the physiotherapist area from a nursing center. The subjects were evaluated in two different sessions at the same time of day, and there was a break of two weeks between sessions. To test the validity of the Leg Motion system, the participants were measured in a weight-bearing lunge position using a classic goniometer with 1° increments, a smartphone with an inclinometer standard app (iPhone 5S® with 1° increments and a measuring tape that could measure 0.1 cm. All testing was performed while the patients were barefoot. The researcher had ten years of experience as a physiotherapist using goniometer, tape measure and inclinometer devices. Results Mean values and standard deviations were as follows: Leg Motion (right 5.15 ± 3.08; left 5.19 ± 2.98, tape measure (right 5.12 ± 3.08; left 5.12 ± 2.80, goniometer (right 45.87° ± 4.98; left 44

  19. Effectiveness of passive stretching versus hold relax technique in flexibility of hamstring muscle

    Directory of Open Access Journals (Sweden)

    Gauri Shankar

    2010-10-01

    Full Text Available Aim: To compare the effectiveness of passive stretching and hold relax technique in the flexibility of hamstring muscle. Methods: A total of 80 normal healthy female subjects between age group 20-30 years referred to the department of physiotherapy, Sumandeep Vidyapeeth University, sampling method being convenient sampling. The subjects were randomly divided in two groups i.e. passive stretching group (n=40 and PNF group (n=40 and given passive stretching and proprioceptive neuromuscular facilitation technique respectively. Active knee extension range was measured before and after the intervention by goniometer. Results: t test showed a highly significant (p=0.000 increase in range of motion in PNF group. Conclusion: Proprioceptive neuromuscular facilitation technique is more effective in increasing hamstring flexibility than the passive stretching.

  20. Modeling of hand function by mapping the motion of individual muscle voxels with MR imaging velocity tagging

    International Nuclear Information System (INIS)

    Drace, J.; Pele, N.; Herfkens, R.J.

    1990-01-01

    This paper reports on a method to correlate the three-dimensional (3D) motion of the fingers with the complex motion of the intrinsic, flexor, and extensor muscles. A better understanding of hand function is important to the medical, surgical, and rehabilitation treatment of patients with arthritic, neurogenic, and mechanical hand dysfunctions. Static, high-resolution MR volumetric imaging defines the 3D shape of each individual bone in the hands of three subjects and three patients. Single-section velocity-tagging sequences (VIGOR) are performed through the hand and forearm, while the actual 3D motion of the hand is computed from the MR model and readings of fiber-optic goniometers attached to each finger. The accuracy of the velocity tagging is also tested with a motion phantom

  1. Experimental design for reflection measurements of highly reactive liquid or solid substances with application to liquid sodium

    International Nuclear Information System (INIS)

    Chan, S.H.; Gossler, A.A.

    1980-01-01

    This technical report describes the experimental part of a program on thermal radiation properties of reactor materials. A versatile goniometer system with associated electronic components and mechanical instruments has been assembled. It is designed to measure spectral, specular reflectances of highly reactive liquid or solid substances over a spectral range of 0.3 μ to 9 μ and incidence angles of 12 0 to 30 0 off the normal direction. The capability of measuring reflectances of liquid substances clearly distinguishes this experimental design from conventional systems which are applicable only to solid substances. This design has been used to measure the spectral, specular reflectance of liquid sodium and preliminary results obtained are compared with those of solid sodium measured by other investigators

  2. X-ray powder crystallography with vertex instrumentation

    International Nuclear Information System (INIS)

    Chatzisotiriou, V.; Christofis, I.; Dimitriou, N.; Karvelas, S.; Karydas, A.G.; Loukas, D.; Pavlidis, A.; Spirou, S.; Dre, C.; Haralabidis, N.; Misiakos, K.; Tsoi, E.; Perdikatsis, V.; Psycharis, V.; Terzis, A.; Turchetta, R.

    1998-01-01

    An X-ray Diffractometer for Powder Crystallography is described along with experimental results and future plans. This is an intermediate instrument toward a long linear array system. Three channels of a silicon microstrip detector, are the detecting elements in the present instrument. Each detector channel is followed by a VLSI readout chain, which consists of a charge preamplifier with pulse shaping circuitry, a discriminator, and a 16-bit counter. Control and data acquisition is performed with a custom made PC readout card. A motorized goniometer scans the angle range of interest. Calibration of the system is done with reference samples and data which are captured with a one-channel conventional NaI detector. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  3. Effects of the shape properties of talc and quartz particles on the wettability based separation processes

    International Nuclear Information System (INIS)

    Hicyilmaz, C.; Ulusoy, U.; Yekeler, M.

    2004-01-01

    Shape properties of talc and quartz particles ground by a laboratory size ball, rod, and autogenous mills were studied using scanning electron microscope (SEM). More than 100 particles were measured to do the shape analysis of each mill product. The wettability behavior of (γ c ) a highly hydrophobic of talc mineral was determined by contact angle measurements and micro-flotation tests using a contact angle goniometer and EMDEE MicroFLOT test tube, respectively. On the other hand, wettability (γ c ) of quartz, which is a highly hydrophilic mineral, was determined by the micro-flotation method only. The results showed that the particles ground by rod mill gave higher flatness and elongation ratio, which meant higher hydrophobicity with lower γ c values in the separations by flotation method

  4. Making sense of nanocrystal lattice fringes

    International Nuclear Information System (INIS)

    Fraundorf, P.; Qin Wentao; Moeck, Peter; Mandell, Eric

    2005-01-01

    The orientation dependence of thin-crystal lattice fringes can be gracefully quantified using fringe-visibility maps, a direct-space analog of Kikuchi maps [Nishikawa and Kikuchi, Nature (London) 121, 1019 (1928)]. As in navigation of reciprocal space with the aid of Kikuchi lines, fringe-visibility maps facilitate acquisition of crystallographic information from lattice images. In particular, these maps can help researchers to determine the three-dimensional lattice of individual nanocrystals, to 'fringe-fingerprint' collections of randomly oriented particles, and to measure local specimen thickness with only a modest tilt. Since the number of fringes in an image increases with maximum spatial-frequency squared, these strategies (with help from more precise goniometers) will be more useful as aberration correction moves resolutions into the subangstrom range

  5. A High Sensitivity EPR Technique for Alanine Dosimetry (invited paper)

    International Nuclear Information System (INIS)

    Haskell, E.H.; Hayes, R.B.; Kenner, G.H.

    1998-01-01

    Uncertainties of ± 5 mGy were achieved in the measurement of alanine dosemeters using optimised EPR parameters, instrumentation, spectral manipulation and subtraction techniques. Modulation amplitude and microwave power were adjusted to combine resonances of two neighbouring alanine signals. Instrumental variations were minimised by combining and subtracting pre- and post-measurement spectra of the empty EPR tube. A spectrum of the native signal of non-dosed alanine was generated from a single batch of dosemeters and subtracted from spectra of the irradiated dosemeters, also from the same batch. Field alignment was adjusted with the use of an in-cavity Mn ++ standard. A constant rotation goniometer was used to eliminate anisotropies in the EPR tube and alanine samples. Finally, digital filters were applied to the resulting spectra. (author)

  6. Automation of an X-ray diffractometer using a manually preset control system

    International Nuclear Information System (INIS)

    Berry, T.; Prentice, P.C.

    1978-11-01

    The measurements of lattice parameters of beta silicon carbide nuclear reactor temperature monitors at Dounreay were formerly carried out using an X-ray diffractometer connected to a simple step scan control system with an analysis time of 8 hours per specimen. A system is described whereby the step scan throughout of the X-ray diffractometer is increased by using an automatic sample charger and additional control electronics, allowing round-the-clock analysis. The original system which used Harwell 2000 series electronic units has been expanded to include an AERE designed goniometer control unit, a Philips sample changer with control unit, and a Honeywell chart recorder. The integrated circuit logic used, interconnections of modules, and operating instructions are given in appendices. (UK)

  7. Latest Developments in Data Analysis and Structure Determination and Refinement: Software for Chemical Crystallography

    International Nuclear Information System (INIS)

    Dix, I.; Adam, M.; Jacob, H. F.; Roter, A.

    2003-01-01

    The introduction of a two-dimensional CCD X-ray detector nearly 10 years ago by Bruker started a revolution in chemical crystallography. Since then, crystallographers can accomplish a complete data collection even of small and poorly scattering crystals in a few hours instead of days. The launch of the kappa geometry by Nonius a few years ago beforehand equally revolutionized the field of single crystal diffractometry. Currently Bruker Nonius has far more than 500 CCD systems installed. The latest development of Bruker Nonius, the X8 APEX, is the powerful combination of both: the APEX CCD detector and the unique Kappa four-circle goniometer. The APEX 4K CCD detector provides the utmost sensitivity, while the Kappa four-circle goniometer offers a very open geometry, granting all the flexibility to align any crystallographic axis. This provides a more efficient data collection for axial photographs to investigate e.g. diffuse scattering or incommensurate structures. Even the crystal-detector distance is computer-controlled for precise and superior data collection. The X8 APEX software suite gives a whole new look to the CCD users interface. It not only has improved data collection abilities, but also guides the chemist or mineralogist through gathering the raw crystal data to producing the final crystal structure. It provides context-dependent menus, which are well-known from business software packages such as Outlook. The tools for unit cell determination, views into reciprocal space, optimisation of the data collection strategy, data integration, scaling and correcting (SADABS) as well as tools for structure solving and refining (SHELXTL package) will be presented. Low temperature work has become an essential tool for challenging samples. The Bruker Nonius Kryo-Flex cryogenic device makes chemical crystallography at low temperatures a routine method in your laboratory. Of course, the Kryo-Flex is fully controlled by the new graphical user interface of the X8 APEX

  8. Reliability of the American Medical Association guides' model for measuring spinal range of motion. Its implication for whole-person impairment rating.

    Science.gov (United States)

    Nitschke, J E; Nattrass, C L; Disler, P B; Chou, M J; Ooi, K T

    1999-02-01

    Repeated measures design for intra- and interrater reliability. To determine the intra- and interrater reliability of the lumbar spine range of motion measured with a dual inclinometer, and the thoracolumbar spine range of motion measured with a long-arm goniometer, as recommended in the American Medical Association Guides. The American Medical Association Guides (2nd and 4th editions) recommend using measurements of thoracolumbar and lumbar range of movement, respectively, to estimate the percentage of permanent impairment in patients with chronic low back pain. However, the reliability of this method of estimating impairment has not been determined. In all, 34 subjects participated in the study, 21 women with a mean age of 40.1 years (SD, +/- 11.1) and 13 men with a mean age of 47.7 years (SD, +/- 12.1). Measures of thoracolumbar flexion, extension, lateral flexion, and rotation were obtained with a long-arm goniometer. Lumbar flexion, extension, and lateral flexion were measured with a dual inclinometer. Measurements were taken by two examiners on one occasion and by one examiner on two occasions approximately 1 week apart. The results showed poor intra- and interrater reliability for all measurements taken with both instruments. Measurement error expressed in degrees showed that measurements taken by different raters exhibited systematic as well as random differences. As a result, subjects measured by two different examiners on the same day, with either instrument, could give impairment ratings ranging between 0% and 18% of the whole person (excluding rotation), in which percentage impairment is calculated using the average range of motion and the average systematic and random error in degrees for the group for each movement (flexion, extension, and lateral flexion). The poor reliability of the American Medical Association Guides' spinal range of motion model can result in marked variation in the percentage of whole-body impairment. These findings have

  9. Automation in structural biology beamlines of the Photon Factory

    International Nuclear Information System (INIS)

    Igarashi, Noriyuki; Hiraki, Masahiko; Matsugaki, Naohiro; Yamada, Yusuke; Wakatsuki, Soichi

    2007-01-01

    The Photon Factory currently operates four synchrotron beamlines for protein crystallography and two more beamlines are scheduled to be constructed in the next years. Over the last years these beamlines have been upgraded and equipped with a fully automated beamline control system based on a robotic sample changer. The current system allows for remote operation, controlled from the user's area, of sample mounting, centering and data collection of pre-frozen crystals mounted in Hampton-type cryo-loops on goniometer head. New intuitive graphical user interfaces have been developed so as to control the complete beamline operation. Furthermore, algorithms for automatic sample centering based on pattern matching and X-ray beam scanning are being developed and combined with newly developed diffraction evaluation programs in order to complete entire automation of the data collection. (author)

  10. Self assembled monolayers of octadecyltrichlorosilane for dielectric materials

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Vijay, E-mail: cirivijaypilani@gmail.com [Centre for Nanoscience and Engineering, Indian Institute of Science-Bangalore (India); Mechanical Engineering Department, Birla Institute of Technology and Science-Pilani (India); Puri, Paridhi; Nain, Shivani [Mechanical Engineering Department, Birla Institute of Technology and Science-Pilani (India); Bhat, K. N. [Centre for Nanoscience and Engineering, Indian Institute of Science-Bangalore (India); Sharma, N. N. [Mechanical Engineering Department, Birla Institute of Technology and Science-Pilani (India); School of Automobile, Mechanical & Mechatronics, Manipal University-Jaipur (India)

    2016-04-13

    Treatment of surfaces to change the interaction of fluids with them is a critical step in constructing useful microfluidics devices, especially those used in biological applications. Selective modification of inorganic materials such as Si, SiO{sub 2} and Si{sub 3}N{sub 4} is of great interest in research and technology. We evaluated the chemical formation of OTS self-assembled monolayers on silicon substrates with different dielectric materials. Our investigations were focused on surface modification of formerly used common dielectric materials SiO{sub 2}, Si{sub 3}N{sub 4} and a-poly. The improvement of wetting behaviour and quality of monolayer films were characterized using Atomic force microscope, Scanning electron microscope, Contact angle goniometer, Raman spectroscopy and X-ray photoelectron spectroscopy (XPS) monolayer deposited oxide surface.

  11. UA9 report for 2012

    CERN Document Server

    Scandale, W

    2012-01-01

    This paper describes the recent UA9 progress adding new evidence to the feasibility of crystal-assisted collimation in hadron colliders. A new goniometer with shorter crystals was used to more efficiently deflect the SPS beam halo with a larger reduction of the off-momentum halo generated in the collimation system. Such a reduction was particularly remarkable for heavy-ions. A considerable reduction of losses was detected by the loss-maps along the whole accelerator circumference. A fraction of the running time was devoted to optimize the configuration of the collimator setup in view of maximizing the collimation efficiency and to investigate effects that could play an important role in LHC. In the North Area the activity devoted to the characterization of the crystals for the SPS and LHC was continued.

  12. Effective atomic number and effective electron densities of some inorganic compounds for Compton effect in the gamma energy range 280 keV to 1115 keV

    International Nuclear Information System (INIS)

    Prasannakumar, S.; Umesh, T.K.

    2014-01-01

    The effective atomic number and effective electron densities of some inorganic compounds for Compton effect in the gamma energy range 280 keV to 1115 keV by using Compton scattering cross sections which are determined on a goniometer assembly. An ORTEC model 23210 gamma-x high purity germanium detector (HpGe) has been used to record the data along with a personal computer based MCA in the angular region 50°-110°. The effective atomic numbers so obtained were found to be equal to the total number of electrons present in the sample in accordance with the chemical formula. The results so obtained are of first of their kind at these energies and are expected to be important in a variety of applications of radiation physics and chemistry. (author)

  13. Certain methods for improving the accuracy of lattice parameter determination in sloping scanning with the use of single-crystal spectrometer

    International Nuclear Information System (INIS)

    Pinegin, V.I.; Koz'ma, A.A.; Fuks, M.Ya.

    1985-01-01

    Errors are accounted for the sloping scanning that is a base of X-ray tenzometry and requires high accuracy of lattice parameter determination including a limp state parameter. A technique is suggested for elimination of systematic alignment errors due to deviation of the primary beam and eccentricity of an irradiated sample surface relative to the main axis of a goniometer. The technique allows to decrease a relative error in interplanar distance determination from 10 -4 to 10 -5 using the DRON-20 diffractometer. Analytical expressions are obtained for correction calculations. The technique can be used in sloping scanning of imperfect single- and polycrystals. Experimental test of the technique has been carried out with epitaxy single-crystal nickel films 500 to 2000 A thick with the use of copper radiation

  14. Crystalline texture study of Zr-2.5%Nb pressure pipes by DRX pole figures

    International Nuclear Information System (INIS)

    Buioli, C P; Banchik, A D; Vizcaino, P; Samper, R; Testone, S

    2012-01-01

    This work presents the study of crystalline texture of Zr-2.5%Nb pressure tubes (A, B and C); structural components of CANDU nuclear power reactors [1]. The study of texture was made using the RX diffraction technique, making measurements of direct pole figures [2], in a Phillips diffractometer with pole goniometer (IFIR-CONICET). The texture was determined calculating the coefficients of JJ Kearns [3]. The samples used correspond to transversal sections of the tubes, front and back, and were characterized making de measurements of five pole figures with Miller index (001), (100), (101), (102) and (110), in order to represent in a complete way the texture in the material. The calculated Kearns coefficients were compared with the specifications given by the designer of pressure tubes AECL [4] (author)

  15. Observation of channeling for 6500 GeV/c protons in the crystal assisted collimation setup for LHC

    International Nuclear Information System (INIS)

    Scandale, W.; Arduini, G.; Butcher, M.; Cerutti, F.; Garattini, M.; Gilardoni, S.; Lechner, A.; Losito, R.; Masi, A.; Mirarchi, D.; Montesano, S.; Redaelli, S.; Rossi, R.; Schoofs, P.; Smirnov, G.; Valentino, G.; Breton, D.; Burmistrov, L.; Chaumat, V.; Dubos, S.

    2016-01-01

    Two high-accuracy goniometers equipped with two bent silicon crystals were installed in the betatron cleaning insertion of the CERN Large Hadron Collider (LHC) during its long shutdown. First beam tests were recently performed at the LHC with 450 GeV/c and 6500 GeV/c stored proton beams to investigate the feasibility of beam halo collimation assisted by bent crystals. For the first time channeling of 6500 GeV/c protons was observed in a particle accelerator. A strong reduction of beam losses due to nuclear inelastic interactions in the aligned crystal in comparison with its amorphous orientation was detected. The loss reduction value was about 24. Thus, the results show that deflection of particles by a bent crystal due to channeling is effective for this record particle energy.

  16. Observation of channeling for 6500 GeV/c protons in the crystal assisted collimation setup for LHC

    Energy Technology Data Exchange (ETDEWEB)

    Scandale, W. [CERN, European Organization for Nuclear Research, CH-1211 Geneva 23 (Switzerland); Laboratoire de l' Accelerateur Lineaire (LAL), Universite Paris Sud Orsay, Orsay (France); INFN Sezione di Roma, Piazzale Aldo Moro 2, 00185 Rome (Italy); Arduini, G.; Butcher, M.; Cerutti, F.; Garattini, M.; Gilardoni, S.; Lechner, A.; Losito, R.; Masi, A.; Mirarchi, D.; Montesano, S.; Redaelli, S. [CERN, European Organization for Nuclear Research, CH-1211 Geneva 23 (Switzerland); Rossi, R. [CERN, European Organization for Nuclear Research, CH-1211 Geneva 23 (Switzerland); INFN Sezione di Roma, Piazzale Aldo Moro 2, 00185 Rome (Italy); Schoofs, P. [CERN, European Organization for Nuclear Research, CH-1211 Geneva 23 (Switzerland); Smirnov, G. [CERN, European Organization for Nuclear Research, CH-1211 Geneva 23 (Switzerland); INFN Sezione di Roma, Piazzale Aldo Moro 2, 00185 Rome (Italy); Valentino, G. [CERN, European Organization for Nuclear Research, CH-1211 Geneva 23 (Switzerland); Breton, D.; Burmistrov, L.; Chaumat, V.; Dubos, S. [Laboratoire de l' Accelerateur Lineaire (LAL), Universite Paris Sud Orsay, Orsay (France); and others

    2016-07-10

    Two high-accuracy goniometers equipped with two bent silicon crystals were installed in the betatron cleaning insertion of the CERN Large Hadron Collider (LHC) during its long shutdown. First beam tests were recently performed at the LHC with 450 GeV/c and 6500 GeV/c stored proton beams to investigate the feasibility of beam halo collimation assisted by bent crystals. For the first time channeling of 6500 GeV/c protons was observed in a particle accelerator. A strong reduction of beam losses due to nuclear inelastic interactions in the aligned crystal in comparison with its amorphous orientation was detected. The loss reduction value was about 24. Thus, the results show that deflection of particles by a bent crystal due to channeling is effective for this record particle energy.

  17. DA+ data acquisition and analysis software at the Swiss Light Source macromolecular crystallography beamlines.

    Science.gov (United States)

    Wojdyla, Justyna Aleksandra; Kaminski, Jakub W; Panepucci, Ezequiel; Ebner, Simon; Wang, Xiaoqiang; Gabadinho, Jose; Wang, Meitian

    2018-01-01

    Data acquisition software is an essential component of modern macromolecular crystallography (MX) beamlines, enabling efficient use of beam time at synchrotron facilities. Developed at the Paul Scherrer Institute, the DA+ data acquisition software is implemented at all three Swiss Light Source (SLS) MX beamlines. DA+ consists of distributed services and components written in Python and Java, which communicate via messaging and streaming technologies. The major components of DA+ are the user interface, acquisition engine, online processing and database. Immediate data quality feedback is achieved with distributed automatic data analysis routines. The software architecture enables exploration of the full potential of the latest instrumentation at the SLS MX beamlines, such as the SmarGon goniometer and the EIGER X 16M detector, and development of new data collection methods.

  18. EPR dosimetry of whole deciduous tooth using a constant rotation goniometer and background subtraction with a dentine standard

    International Nuclear Information System (INIS)

    Haskell, E.H.; Hayes, R.B.; Kenner, G.H.

    1996-01-01

    We report here a rapid method of electron paramagnetic resonance (EPR) dosimetry of dental enamel which will allow screening of whole deciduous teeth of children following a nuclear accident. The technique requires virtually no sample preparation and is capable of measuring doses of less than 100 mGy. Teeth may be scanned for threshold dose levels without the need for added calibration doses and those of particular interest may be more accurately examined using the additive dose method. The success of the technique lies in the elimination of anisotropic effects by rotation of spectra from the empty cavity and a standard background tooth. Normalization using in- cavity Mn++ standards is also employed

  19. BIDIRECTIONAL DISTRIBUTION FUNCTION (BRDF) CHARACTERISTICS OF SMOOTH CORDGRASS (SPARTINA ALTERNIFLORA) OBTAINED USING A SANDMEIER FIELD GONIOMETER. (R826944)

    Science.gov (United States)

    The perspectives, information and conclusions conveyed in research project abstracts, progress reports, final reports, journal abstracts and journal publications convey the viewpoints of the principal investigator and may not represent the views and policies of ORD and EPA. Concl...

  20. Vacuum variable-angle far-infrared ellipsometer

    Science.gov (United States)

    Friš, Pavel; Dubroka, Adam

    2017-11-01

    We present the design and performance of a vacuum far-infrared (∼50-680 cm-1) ellipsometer with a rotating analyser. The system is based on a Fourier transform spectrometer, an in-house built ellipsometer chamber and a closed-cycle bolometer. The ellipsometer chamber is equipped with a computer controlled θ-2θ goniometer for automated measurements at various angles of incidence. We compare our measurements on SrTiO3 crystal with the results acquired above 300 cm-1 with a commercially available ellipsometer system. After the calibration of the angle of incidence and after taking into account the finite reflectivity of mirrors in the detector part we obtain a very good agreement between the data from the two instruments. The system can be supplemented with a closed-cycle He cryostat for measurements between 5 and 400 K.

  1. Methods of total spectral radiant flux realization at VNIIOFI

    Science.gov (United States)

    Ivashin, Evgeniy; Lalek, Jan; Rybczyński, Andrzej; Ogarev, Sergey; Khlevnoy, Boris; Dobroserdov, Dmitry; Sapritsky, Victor

    2018-02-01

    VNIIOFI carries out works on realization of independent methods for realization of the total spectral radiant flux (TSRF) of incoherent optical radiation sources - reference high-temperature blackbodies (BB), halogen lamps, and LED with quasi-Lambert spatial distribution of radiance. The paper describes three schemes for measuring facilities using photometers, spectroradiometers and computer-controlled high class goniometer. The paper describes different approaches for TSRF realization at the VNIIOFI National radiometric standard on the basis of high-temperature BB and LED sources, and gonio-spectroradiometer. Further, they are planned to be compared, and the use of fixed-point cells (in particular, based on the high-temperature δ(MoC)-C metal-carbon eutectic with a phase transition temperature of 2583 °C corresponding to the metrological optical “source-A”) as an option instead of the BB is considered in order to enhance calibration accuracy.

  2. In vitro biocompatibility of plasma-aided surface-modified 316L stainless steel for intracoronary stents

    International Nuclear Information System (INIS)

    Bayram, Cem; Denkbas, Emir Baki; Mizrak, Alpay Koray; Aktuerk, Selcuk; Kursaklioglu, Hurkan; Iyisoy, Atila; Ifran, Ahmet

    2010-01-01

    316L-type stainless steel is a raw material mostly used for manufacturing metallic coronary stents. The purpose of this study was to examine the chemical, wettability, cytotoxic and haemocompatibility properties of 316L stainless steel stents which were modified by plasma polymerization. Six different polymeric compounds, polyethylene glycol, 2-hydroxyethyl methacrylate, ethylenediamine, acrylic acid, hexamethyldisilane and hexamethyldisiloxane, were used in a radio frequency glow discharge plasma polymerization system. As a model antiproliferative drug, mitomycin-C was chosen for covalent coupling onto the stent surface. Modified SS 316L stents were characterized by water contact angle measurements (goniometer) and x-ray photoelectron spectroscopy. C1s binding energies showed a good correlation with the literature. Haemocompatibility tests of coated SS 316L stents showed significant latency (t-test, p < 0.05) with respect to SS 316L and control groups in each test.

  3. Microstructure and local texture of partially recrystallized titanium sheet

    International Nuclear Information System (INIS)

    Zaefferer, S.; Schwarzer, R.A.

    1993-01-01

    The microstructure of TiAl6V4 sheet was investigated by transmission electron microscopy. Two types of microstructure were found: regions with a recrystallized and regions with a deformed structure. They could be distinguished from each other by grain size and shape, by the dislocation density and local texture. The orientations of individual grains were measured by on-line interpretation of Kikuchi patterns with a TEM. The results were represented on inverse pole figures. The deformed structure showed a strong preferred orientation (11 anti 20)[10 anti 10], while the texture of the recrystallized areas was substantially weaker containing other preferred orientations. The global texture of the sample was investigated by measuring pole figures with an x-ray texture goniometer. The ODF as well as inverse pole figures were calculated and compared to the TEM pole figures. (orig.)

  4. The method of contact angle measurements and estimation of work of adhesion in bioleaching of metals

    Directory of Open Access Journals (Sweden)

    Matlakowska Renata

    1999-01-01

    Full Text Available In this paper, we present our method for the measurement of contact angles on the surface of minerals during the bioleaching process because the standard deviation obtained in our measurements achieved unexpectedly low error. Construction of a goniometer connected with a specially prepared computer program allowed us to repeat measurements several times over a short time course, yielding excellent results. After defining points on the outline of the image of a drop and its baseline as well of the first approximation of the outline of the drop, an iterative process is initiated that is aimed at fitting the model of the drop and baseline. In turn, after defining the medium for which measurements were made, the work of adhesion is determined according to Young-Dupré equation. Calculations were made with the use of two methods named the L-M and L-Q methods.

  5. Setup for in situ x-ray diffraction study of swift heavy ion irradiated materials

    Science.gov (United States)

    Kulriya, P. K.; Singh, F.; Tripathi, A.; Ahuja, R.; Kothari, A.; Dutt, R. N.; Mishra, Y. K.; Kumar, Amit; Avasthi, D. K.

    2007-11-01

    An in situ x-ray diffraction (XRD) setup is designed and installed in the materials science beam line of the Pelletron accelerator at the Inter-University Accelerator Centre for in situ studies of phase change in swift heavy ion irradiated materials. A high vacuum chamber with suitable windows for incident and diffracted X-rays is integrated with the goniometer and the beamline. Indigenously made liquid nitrogen (LN2) temperature sample cooling unit is installed. The snapshots of growth of particles with fluence of 90MeV Ni ions were recorded using in situ XRD experiment, illustrating the potential of this in situ facility. A thin film of C60 was used to test the sample cooling unit. It shows that the phase of the C60 film transforms from a cubic lattice (at room temperature) to a fcc lattice at around T =255K.

  6. In-situ capability of ion beam modification and characterization of materials at Los Alamos National Laboratory

    International Nuclear Information System (INIS)

    Yu, N.; Nastasi, M.; Tesmer, J.R.; Hollander, M.G.; Evans, C.R.; Maggiore, C.J.; Levine, T.E.

    1994-01-01

    The capability of in-situ ion beam modification and characterization of materials developed at Los Alamos National Laboratory is described. A beam-line from a 3 MV tandem accelerator and a beam-line from a 200 kV ion implanter are joined together in an in-situ target chamber. The chamber is equipped with a cold and hot sample stage with a temperature range from -100 to 500 C. The angular (sample spin and basal rotation) motions and translational motions of the sample stage are controlled by a multi-axis goniometer. This chamber provides a unique capability to conduct a temperature dependent experiment of ion irradiation and sequential backscattering and channeling analysis. The efficiency and reliability of in-situ ion beam techniques are demonstrated by two examples, irradiation damage in (100) MgAl 2 O 4 spinel crystals and ion-beam-induced densification of zirconia sol-gel thin films

  7. Setup for in situ x-ray diffraction study of swift heavy ion irradiated materials.

    Science.gov (United States)

    Kulriya, P K; Singh, F; Tripathi, A; Ahuja, R; Kothari, A; Dutt, R N; Mishra, Y K; Kumar, Amit; Avasthi, D K

    2007-11-01

    An in situ x-ray diffraction (XRD) setup is designed and installed in the materials science beam line of the Pelletron accelerator at the Inter-University Accelerator Centre for in situ studies of phase change in swift heavy ion irradiated materials. A high vacuum chamber with suitable windows for incident and diffracted X-rays is integrated with the goniometer and the beamline. Indigenously made liquid nitrogen (LN2) temperature sample cooling unit is installed. The snapshots of growth of particles with fluence of 90 MeV Ni ions were recorded using in situ XRD experiment, illustrating the potential of this in situ facility. A thin film of C60 was used to test the sample cooling unit. It shows that the phase of the C60 film transforms from a cubic lattice (at room temperature) to a fcc lattice at around T=255 K.

  8. Mechanical design of a high-resolution x-ray powder diffractometer at the Advanced Photon Source.

    Energy Technology Data Exchange (ETDEWEB)

    Shu, D.; Lee, P.; Preissner, C.; Ramanathan, M.; Beno, M.; VonDreele, R.; Ranay, R.; Ribaud, L.; Kurtz, C.; Jiao, X.; Kline, D.; Jemian, P.; Toby, B.

    2007-01-01

    A novel high-resolution x-ray powder diffractometer has been designed and commissioned at the bending magnet beamline 11-BM at the Advanced Photon Source (APS), Argonne National Laboratory (ANL). This state-of-the-art instrument is designed to meet challenging mechanical and optical specifications for producing high-quality powder diffraction data with high throughput. The 2600 mm (H) X 2100 mm (L) X 1700 mm (W) diffractometer consists of five subassemblies: a customized two-circle goniometer with a 3-D adjustable supporting base; a twelve-channel high-resolution crystal analyzer system with an array of precision x-ray slits; a manipulator system for a twelve scintillator x-ray detectors; a 4-D sample manipulator with cryo-cooling capability; and a robot-based sample exchange automation system. The mechanical design of the diffractometer as well as the test results of its positioning performance are presented in this paper.

  9. Mechanical design of a high-resolution x-ray powder diffractometer at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Shu, D.; Lee, P.; Preissner, C.; Ramanathan, M.; Beno, M.; VonDreele, R.; Ranay, R.; Ribaud, L.; Kurtz, C.; Jiao, X.; Kline, D.; Jemian, P.; Toby, B.

    2007-01-01

    A novel high-resolution x-ray powder diffractometer has been designed and commissioned at the bending magnet beamline 11-BM at the Advanced Photon Source (APS), Argonne National Laboratory (ANL). This state-of-the-art instrument is designed to meet challenging mechanical and optical specifications for producing high-quality powder diffraction data with high throughput. The 2600 mm (H) X 2100 mm (L) X 1700 mm (W) diffractometer consists of five subassemblies: a customized two-circle goniometer with a 3-D adjustable supporting base; a twelve-channel high-resolution crystal analyzer system with an array of precision x-ray slits; a manipulator system for a twelve scintillator x-ray detectors; a 4-D sample manipulator with cryo-cooling capability; and a robot-based sample exchange automation system. The mechanical design of the diffractometer as well as the test results of its positioning performance are presented in this paper.

  10. Studies of deformation-induced texture development in sheet materials using diffraction techniques

    International Nuclear Information System (INIS)

    Banovic, S.W.; Vaudin, M.D.; Gnaeupel-Herold, T.H.; Saylor, D.M.; Rodbell, K.P

    2004-01-01

    Crystallographic texture measurements were made on a series of rolled aluminum sheet specimens deformed in equi-biaxial tension up to a strain level of 0.11. The measurement techniques used were neutron diffraction with a 4-circle goniometer, electron backscatter diffraction, conventional powder X-ray diffraction (XRD), and XRD using an area detector. Results indicated a complex texture orientation distribution function which altered in response to the applied plastic deformation. Increased deformation caused the {1 1 0} planes, to align parallel to the plane of the sheet. The different techniques produced results that were very consistent with each other. The advantages and disadvantages of the various methods are discussed, with particular consideration of the time taken for each method, the range of orientation space accessible, the density of data that can be obtained, and the statistical significance of each data set with respect to rolled sheet product

  11. Running Related Injury, Mileage And Q-angle: A Prospective Follow-up Study

    DEFF Research Database (Denmark)

    Ramskov, Daniel; Nielsen, R.O.; Rasmussen, Sten

    2012-01-01

    The Quadriceps angle (Q-angle) may be associated with the development of Running Related Injuries (RRI). Only a few studies have investigated the association between Q-angle, and the likelihood of RRI. These studies have not led to any firm conclusions, on the link between Q-angle and development...... of RRI. To our knowledge, none of these studies have taken mileage into account, which may be an import part of the causal pathways leading to injury development. PUR POSE : To investigate if mileage to RRI differs between novice runners with different Q-angles. MET HODS: Participants were recruited via...... an online questionnaire. Inclusion criteria’s were, age 18-65, running must not have exceeded 10km in total the past year, healthy individuals, consent to run at least two times pr. week over a 10 week period. Q-angle was measured at baseline, using a standard goniometer, the participant lying supine...

  12. The effects of complex exercise on shoulder range of motion and pain for women with breast cancer-related lymphedema: a single-blind, randomized controlled trial.

    Science.gov (United States)

    Park, Jin-Hyuck

    2017-07-01

    This study was to investigate the effects of complex exercise on shoulder range of motion and pain for women with breast cancer-related lymphedema. 69 women participated in this study and then they were randomly allocated to complex exercise group (n = 35) or the conventional decongestive therapy group (n = 34). All subjects received 8 sessions for 4 weeks. To identify the effects on shoulder range of motion and pain, goniometer and visual analog scale were used, respectively. The outcome measurements were performed before and after the 4 week intervention. After 4 weeks, complex exercise group had greater improvements in shoulder range of motion and pain compared with the conventional decongestive therapy group (p women with breast cancer-related lymphedema. Complex exercise would be useful to improve shoulder range of motion and pain of the women with breast cancer-related lymphedema.

  13. Shoulder rotational profiles in young healthy elite female and male badminton players

    DEFF Research Database (Denmark)

    Couppé, C; Thorborg, K; Hansen, Mette

    2014-01-01

    The aim of the present study was to profile shoulder passive range of motion (ROM) and isometric strength for external (ER) and internal (IR) rotation as part of a preseason screening in adolescent national badminton players. Passive external range of motion (EROM) and internal range of motion...... (IROM) were examined on the dominant and nondominant shoulder in 31 adolescent national badminton players (12 females and 19 males) with a standard goniometer. Muscle strength was examined with a hand-held dynamometer in ER and IR. Total range of motion (TROM = EROM+IROM) was lower on the dominant side...... on the dominant side compared with the nondominant side in young elite badminton players, irrespective of gender. No rotational strength differences existed between the dominant and nondominant side in male players, but in female players a higher IR strength on the dominant side was not balanced by a higher ER...

  14. Studies on surface modification of poly(tetrafluoroethylene) film by remote and direct Ar plasma

    International Nuclear Information System (INIS)

    Wang Chen; Chen Jierong; Li Ru

    2008-01-01

    Poly(tetrafluoroethylene) (PTFE) surfaces are modified with remote and direct Ar plasma, and the effects of the modification on the hydrophilicity of PTFE are investigated. The surface microstructures and compositions of the PTFE film were characterized with the goniometer, scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). Results show that the remote and direct plasma treatments modify the PTFE surface in morphology and composition, and both modifications cause surface oxidation of PTFE films, in the forming of some polar functional groups enhancing polymer wettability. When the remote and direct Ar plasma treats PTFE film, the contact angles decrease from the untreated 108-58 o and 65.2 o , respectively. The effect of the remote Ar plasma is more noticeable. The role of all kinds of active species, e.g. electrons, ions and free radicals involved in plasma surface modification is further evaluated. This shows that remote Ar plasma can restrain the ion and electron etching reaction and enhance radical reaction

  15. On the residual stress and picostructure of titanium nitride films. Pt. 1

    International Nuclear Information System (INIS)

    Perry, A.J.; Valvoda, V.; Rafaja, D.; Williamson, D.L.; Sartwell, B.D.

    1992-01-01

    Titanium nitride films, dual energy ion implanted with argon or krypton, have been studied with a Seemann-Bohlin fine focus goniometer at grazing angles in the range 2-10. The implantation of 1% of either gas has little effect on the lattice parameters or the residual stress. It is thought that the gas atoms are on substitutional lattice sites and are associated with vacancies created during the implantation process. At 4% of implanted gas, it precipitates out in the form of bubbles; in the case of argon these are crystalline and their lattice parameter is close to that for solid argon as recorded in the literature. The lattice parameters and the residual stresses are affected slightly by the implantation: argon reduces the former and makes the latter more tensile, whereas the krypton has the opposite effects. It is thought that the difference in behavior is due to a difference in size of the bubbles or to the greater compressibility of argon

  16. Beam equipment electromagnetic interaction in accelerators: simulation and experimental benchmarking

    CERN Document Server

    Passarelli, Andrea; Vaccaro, Vittorio Giorgio; Massa, Rita; Masullo, Maria Rosaria

    One of the most significant technological problems to achieve the nominal performances in the Large Hadron Collider (LHC) concerns the system of collimation of particle beams. The use of collimators crystals, exploiting the channeling effect on extracted beam, has been experimentally demonstrated. The first part of this thesis is about the optimization of UA9 goniometer at CERN, this device used for beam collimation will replace a part of the vacuum chamber. The optimization process, however, requires the calculation of the coupling impedance between the circulating beam and this structure in order to define the threshold of admissible intensity to do not trigger instability processes. Simulations have been performed with electromagnetic codes to evaluate the coupling impedance and to assess the beam-structure interaction. The results clearly showed that the most concerned resonance frequencies are due solely to the open cavity to the compartment of the motors and position sensors considering the crystal in o...

  17. Superhydrophobic transparent films from silica powder: Comparison of fabrication methods

    KAUST Repository

    Liu, Li-Der; Lin, Chao-Sung; Tikekar, Mukul; Chen, Ping-Hei

    2011-01-01

    The lotus leaf is known for its self-clean, superhydrophobic surface, which displays a hierarchical structure covered with a thin wax-like material. In this study, three fabrication techniques, using silicon dioxide particles to create surface roughness followed by a surface modification with a film of polydimethylsiloxane, were applied on a transparent glass substrate. The fabrication techniques differed mainly on the deposition of silicon dioxide particles, which included organic, inorganic, and physical methods. Each technique was used to coat three samples of varying particle load. The surface of each sample was evaluated with contact angle goniometer and optical spectrometer. Results confirmed the inverse relationships between contact angle and optical transmissivity independent of fabrication techniques. Microstructural morphologies also suggested the advantage of physical deposition over chemical methods. In summary, the direct sintering method proved outstanding for its contact angle vs transmissivity efficiency, and capable of generating a contact angle as high as 174°. © 2011 Elsevier B.V. All rights reserved.

  18. Superficial modifications in TiO2 and Al2O3 ceramics

    Directory of Open Access Journals (Sweden)

    Santos Flávio de Paula

    2003-01-01

    Full Text Available The properties of hydrophilicity or hydrophobicity of materials are defined mainly, though not exclusively, by their composition, morphology and surface energy. In this work, titanium dioxide (TiO2 and aluminum oxide-alumina (Al2O3 ceramics prepared by uniaxial pressing were studied in terms of surface energy. The surfaces of these ceramics were treated with nitrogen plasma, using a stainless steel reactor excited by a 13,6 MHz radio frequency operating at 50 W input power and 13 Pa nitrogen pressure. The surface morphology was investigated by scanning electron microscopy (SEM analysis. Surface energy and contact angle measurements were taken using a RAMÉ-HART goniometer. These measurements were taken as function of time, over a 21-day period. The contact angle and surface energy values were found to change by almost 34% in comparison to their initial values immediately following plasma treatment. Nonetheless, the hydrophilic character of the Al2O3 and TiO2 remained constant throughout the test period.

  19. Ultrasonic trap for light scattering measurement

    Science.gov (United States)

    Barton, Petr; Pavlu, Jiri

    2017-04-01

    Light scattering is complex phenomenon occurring widely in space environments, including the dense dusty clouds, nebulas or even the upper atmosphere of the Earth. However, when the size of the dust (or of other scattering center) is close to the incident light wavelength, theoretical determination is difficult. In such case, Mie theory is to be used but there is a lack of the material constants for most space-related materials. For experimental measurement of light scattering, we designed unique apparatus, based on ultrasonic trap. Using acoustic levitation we are able to capture the dust grain in midair, irradiate it with laser, and observe scattering directly with goniometer-mounted photodiode. Advantage of this approach is ability to measure directly in the air (thus, no need for the carrier medium) and possibility to study non-spherical particles. Since the trap development is nearly finished and initial experiments are carried out, the paper presents first tests on water droplets.

  20. Measurements of normal joint angles by goniometry in calves.

    Science.gov (United States)

    Sengöz Şirin, O; Timuçin Celik, M; Ozmen, A; Avki, S

    2014-01-01

    The aim of this study was to establish normal reference values of the forelimb and hindlimb joint angles in normal Holstein calves. Thirty clinically normal Holstein calves that were free of any detectable musculoskeletal abnormalities were included in the study. A standard transparent plastic goniometer was used to measure maximum flexion, maximum extension, and range-of-motion of the shoulder, elbow, carpal, hip, stifle, and tarsal joints. The goniometric measurements were done on awake calves that were positioned in lateral recumbency. The goniometric values were measured and recorded by two independent investigators. As a result of the study it was concluded that goniometric values obtained from awake calves in lateral recumbency were found to be highly consistent and accurate between investigators (p <0.05). The data of this study acquired objective and useful information on the normal forelimb and hindlimb joint angles in normal Holstein calves. Further studies can be done to predict detailed goniometric values from different diseases and compare them.

  1. Apparatus and Experimental Procedures to Test Crystal Collimation

    CERN Document Server

    Montesano, S

    2012-01-01

    UA9 is an experimental setup operated in the CERN-SPS in view of investigating the feasibility of halo collimation assisted by bent crystals. The test collimation system is composed of one crystal acting as primary halo deflector in the horizontal plane and an absorber. Different crystals are tested in turn using two-arm goniometers with an angular reproducibility of better than 10 microrad. The performance of the system is assessed through the study of the secondary and tertiary halo in critical areas, by using standard machine instrumentation and few customized equipments. The alignment of the crystal is verified by measuring the loss rate close to the crystal position. The collimation efficiency is computed by intercepting the deflected halo with a massive collimator or with an imaging device installed into a Roman Pot. The leakage of the system is evaluated in the dispersion suppressor by means of movable aperture restrictions. In this contribution the setup and the experimental methods in use are revisit...

  2. Application of a high-temperature neutron diffraction apparatus to the study of refractory oxides

    International Nuclear Information System (INIS)

    Aldebert, P.; Badie, J.-M.; Buevoz, J.-L.; Roult, G.

    1975-01-01

    A furnace allowing studies of refractory materials by neutron diffraction in situ up to 2500 deg C is described. It is fitted on to a new type of time of flight spectrometer the pulsed source of which is given by a correlation chopper. The advantages of this technique in comparison with fixed-wavelength goniometers are developped. The examination at high temperature of several refractory oxides has been carried out with this experimental device. The thermal expansion curve of α alumina has been established with accuracy up to near the melting point. Several high temperature cristalline forms, X form La 2 O 3 , the tetragonal and cubic ZrO 2 , tetragonal HfO 2 , have been studied. Concerning the latter two, the case of their solid solutions 2MO 2 -M' 2 O 3 (with M=Hf or Zr and M'=La or Y) has also been considered, at room temperature only [fr

  3. In situ macromolecular crystallography using microbeams.

    Science.gov (United States)

    Axford, Danny; Owen, Robin L; Aishima, Jun; Foadi, James; Morgan, Ann W; Robinson, James I; Nettleship, Joanne E; Owens, Raymond J; Moraes, Isabel; Fry, Elizabeth E; Grimes, Jonathan M; Harlos, Karl; Kotecha, Abhay; Ren, Jingshan; Sutton, Geoff; Walter, Thomas S; Stuart, David I; Evans, Gwyndaf

    2012-05-01

    Despite significant progress in high-throughput methods in macromolecular crystallography, the production of diffraction-quality crystals remains a major bottleneck. By recording diffraction in situ from crystals in their crystallization plates at room temperature, a number of problems associated with crystal handling and cryoprotection can be side-stepped. Using a dedicated goniometer installed on the microfocus macromolecular crystallography beamline I24 at Diamond Light Source, crystals have been studied in situ with an intense and flexible microfocus beam, allowing weakly diffracting samples to be assessed without a manual crystal-handling step but with good signal to noise, despite the background scatter from the plate. A number of case studies are reported: the structure solution of bovine enterovirus 2, crystallization screening of membrane proteins and complexes, and structure solution from crystallization hits produced via a high-throughput pipeline. These demonstrate the potential for in situ data collection and structure solution with microbeams. © 2012 International Union of Crystallography

  4. Superhydrophobic transparent films from silica powder: Comparison of fabrication methods

    KAUST Repository

    Liu, Li-Der

    2011-07-01

    The lotus leaf is known for its self-clean, superhydrophobic surface, which displays a hierarchical structure covered with a thin wax-like material. In this study, three fabrication techniques, using silicon dioxide particles to create surface roughness followed by a surface modification with a film of polydimethylsiloxane, were applied on a transparent glass substrate. The fabrication techniques differed mainly on the deposition of silicon dioxide particles, which included organic, inorganic, and physical methods. Each technique was used to coat three samples of varying particle load. The surface of each sample was evaluated with contact angle goniometer and optical spectrometer. Results confirmed the inverse relationships between contact angle and optical transmissivity independent of fabrication techniques. Microstructural morphologies also suggested the advantage of physical deposition over chemical methods. In summary, the direct sintering method proved outstanding for its contact angle vs transmissivity efficiency, and capable of generating a contact angle as high as 174°. © 2011 Elsevier B.V. All rights reserved.

  5. Write-up for the diffractometer D1 at Risoe

    International Nuclear Information System (INIS)

    Bundgaard, J.; Krebs Larsen, F.; Lebech, B.; Nielsen, M.H.; Skaarup, P.

    1982-05-01

    Manual for the crystallographic program system used to control the 4-circle neutron diffractometer D1/TASII at DR3, Risoe. The mechanical part of the diffractometer consists of a monochromator part which allows an easy change of incident neutron wavelenght and a four-circle HUBER goniostate consisting of an Euler cradle (HUBER 512) and two horizontal goniometers (HUBER 440 and HUBER 430). The goniostate is computer controlled by a PDP-11/34 interfaced via CAMAC modules. The PDP-11/34 computer has a 128 k byte memory, two hard magnetic disc stations, a fast DEC-writer terminal and a screen terminal. The diffractometer can be operated remotely via modem and telephone line connections from remote stations such as the University of Aarhus and ILL, Grenoble. Minor parts of the software used to control the diffractometer were developed at Risoe while the major parts were a generous gift to Risoe from College 5, the diffraction group, at the Institute Laue-Langevin, Grenoble, France. (editors)

  6. The Correlation of Exercise and Range of Motion (ROM on Elderly Knee Observasional Study on Elderly People in Pedurungan Semarang

    Directory of Open Access Journals (Sweden)

    Adhitya Putra Widyantoro

    2012-06-01

    Design and Method: Observastional study with a cross sectional design 80 elderly men and women were divided into 2 groups: gymnastics group in the Social Rehabilitation Unit Of Pucang Gading (n=40 and unexcercises group in the Penggaron village (n=40. In both groups, the degree of ROM of knee was assessed using the Goniometer. To evaluate the value of its significance, the data were analyzed using the Mann Withney test followed by Spearmann’s rho test. Result: ROM for gymnastic(exercised group and unexercised group were 115.50°±11.591°, 95.38°±12.780° respectively with p<0. 001. Resuts showed that doing exercise was useful for maintaining ROM of knee in elderly people. Spearmann’s rho test resulted in a strong correlation between ROM and exercise with r value of 0.652. Conclusion: exercise correlates with ROM of knee in elderly (Sains Medika, 4(1:39-45.

  7. Retracted: Study of the wettability of ZnO nanofilms

    Directory of Open Access Journals (Sweden)

    Ujjwal M Joshi

    2012-04-01

    Full Text Available Al-doped and un-doped ZnO thin films deposited on quartz substrates by the nebulized spray pyrolysis method were studied to investigate the wettability of the surface. The main objective of the present study was to investigate the wettability of ZnO thin film by changing the concentration of Al doping. Microstructure and water contact angles of the films were measured by scanning electron microscopy (SEM and using a contact angle goniometer. SEM studies revealed that the grain size within the film increases with the doping concentration. The contact angles were studied to see the effect of aluminum doping on the hydrophilicity of the film. ZnO films were found to be hydrophobic in nature. A good correlation was observed between the SEM micrographs and contact angle results. The nature of the film was found to change from being hydrophobic to hydrophilic after the treatment in low-pressure DC glow discharge plasma, which, however, was reversible with the storage time.

  8. Effect of Yoga Based Lifestyle Intervention on Patients With Knee Osteoarthritis: A Randomized Controlled Trial

    Science.gov (United States)

    Deepeshwar, Singh; Tanwar, Monika; Kavuri, Vijaya; Budhi, Rana B.

    2018-01-01

    Objective: To investigate the effect of integrated approach of yoga therapy (IAYT) intervention in individual with knee Osteoarthritis. Design: Randomized controlled clincial trail. Participants: Sixty-six individual prediagnosed with knee osteoarthritis aged between 30 and 75 years were randomized into two groups, i.e., Yoga (n = 31) and Control (n = 35). Yoga group received IAYT intervention for 1 week at yoga center of S-VYASA whereas Control group maintained their normal lifestyle. Outcome measures: The Falls Efficacy Scale (FES), Handgrip Strength test (left hand LHGS and right hand RHGS), Timed Up and Go Test (TUG), Sit-to-Stand (STS), and right & left extension and flexion were measured on day 1 and day 7. Results: There were a significant reduction in TUG (p Yoga group. Conclusion: IAYT practice showed an improvement in TUG, STS, HGS, and Goniometer test, which suggest improved muscular strength, flexibility, and functional mobility. CTRI Registration Number: http://ctri.nic.in/Clinicaltrials, identifier CTRI/2017/10/010141. PMID:29867604

  9. Combined Effect of a Microporous Layer and Type I Collagen Coating on a Biphasic Calcium Phosphate Scaffold for Bone Tissue Engineering

    Directory of Open Access Journals (Sweden)

    Mun-Hwan Lee

    2015-03-01

    Full Text Available In this study, type I collagen was coated onto unmodified and modified microporous biphasic calcium phosphate (BCP scaffolds. Surface characterization using a scanning electron microscope (SEM and a surface goniometer confirmed the modification of the BCP coating. The quantity of the collagen coating was investigated using Sirius Red staining, and quantitative assessment of the collagen coating showed no significant differences between the two groups. MG63 cells were used to evaluate cell proliferation and ALP activity on the modified BCP scaffolds. The modified microporous surfaces showed low contact angles and large surface areas, which enhanced cell spreading and proliferation. Coating of the BCP scaffolds with type I collagen led to enhanced cell-material interactions and improved MG63 functions, such as spreading, proliferation, and differentiation. The micropore/collagen-coated scaffold showed the highest rate of cell response. These results indicate that a combination of micropores and collagen enhances cellular function on bioengineered bone allograft tissue.

  10. Rock and mineral magnetism

    CERN Document Server

    O’Reilly, W

    1984-01-01

    The past two decades have witnessed a revolution in the earth sciences. The quantitative, instrument-based measurements and physical models of. geophysics, together with advances in technology, have radically transformed the way in which the Earth, and especially its crust, is described. The study of the magnetism of the rocks of the Earth's crust has played a major part in this transformation. Rocks, or more specifically their constituent magnetic minerals, can be regarded as a measuring instrument provided by nature, which can be employed in the service of the earth sciences. Thus magnetic minerals are a recording magnetometer; a goniometer or protractor, recording the directions of flows, fields and forces; a clock; a recording thermometer; a position recorder; astrain gauge; an instrument for geo­ logical surveying; a tracer in climatology and hydrology; a tool in petrology. No instrument is linear, or free from noise and systematic errors, and the performance of nature's instrument must be assessed and ...

  11. Shoulder rotational profiles in young healthy elite female and male badminton players.

    Science.gov (United States)

    Couppé, C; Thorborg, K; Hansen, M; Fahlström, M; Bjordal, J M; Nielsen, D; Baun, M; Storgaard, M; Magnusson, S P

    2014-02-01

    The aim of the present study was to profile shoulder passive range of motion (ROM) and isometric strength for external (ER) and internal (IR) rotation as part of a preseason screening in adolescent national badminton players. Passive external range of motion (EROM) and internal range of motion (IROM) were examined on the dominant and nondominant shoulder in 31 adolescent national badminton players (12 females and 19 males) with a standard goniometer. Muscle strength was examined with a hand-held dynamometer in ER and IR. Total range of motion (TROM = EROM+IROM) was lower on the dominant side compared with the nondominant side in both groups (P badminton players, irrespective of gender. No rotational strength differences existed between the dominant and nondominant side in male players, but in female players a higher IR strength on the dominant side was not balanced by a higher ER strength. © 2012 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. What's in a ray set: moving towards a unified ray set format

    Science.gov (United States)

    Muschaweck, Julius

    2011-10-01

    For the purpose of optical simulation, a plethora of formats exist to describe the properties of a light source. Except for the EULUMDAT and IES formats which describe sources in terms of aperture area and far field intensity, all these formats are vendor specific, and no generally accepted standard exists. Most illumination simulation software vendors use their own format for ray sets, which describe sources in terms of many rays. Some of them keep their format definition proprietary. Thus, software packages typically can read or write only their own specific format, although the actual data content is not so different. Typically, they describe origin and direction of each ray in 3D vectors, and use one more single number for magnitude, where magnitude may denote radiant flux, luminous flux (equivalently tristimulus Y), or tristimulus X and Z. Sometimes each ray also carries its wavelength, while other formats allow to specify an overall spectrum for the whole source. In addition, in at least one format, polarization properties are also included for each ray. This situation makes it inefficient and potentially error prone for light source manufacturers to provide ray data sets for their sources in many different formats. Furthermore, near field goniometer vendors again use their proprietary formats to store the source description in terms of luminance data, and offer their proprietary software to generate ray sets from this data base. Again, the plethora of ray sets make the ray set production inefficient and potentially error prone. In this paper, we propose to describe ray data sets in terms of phase space, as a step towards a standardized ray set format. It is well known that luminance and radiance can be defined as flux density in phase space: luminance is flux divided by etendue. Therefore, single rays can be thought of as center points of phase space cells, where each cell possesses its volume (i.e. etendue), its flux, and therefore its luminance. In

  13. Neutron Diffractometer; Neutronski difraktometar

    Energy Technology Data Exchange (ETDEWEB)

    Zivadinovic, M [Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Serbia and Montenegro)

    1961-12-15

    RA nuclear reactor is considered as a relatively strong neutron source producing the thermal neutron flux of about 3x10{sup 13} n/cm{sup 2} sec when operating at nominal power of 6.5 MW. Neutron diffraction method is applied in the field of solid state physics, material science, crystallography, magnetism, nuclear physic. Neutron diffractometer at the RA reactor consists of: system for obtaining collimated neutron beam from the horizontal experimental channel neutron monochromator; goniometer and electronic equipment for measurements and collecting the the measurement data. Nuklearni reaktor RA koji pri radu na snazi od 6,5 MW ima fluks termalnih neutrona oko 3x10{sup 13} n/cm{sup 2} sec predstavlja relativno jak izvor neutrona. Tehnika difrakcije neutrona primenjuje se u istrazivanjima fizike crvstog stanja, strukture materijala, kristalografije, magnetizma, nuklearne fizike. Neutronski difraktometar na reaktoru RA sastoji se od sistema za dobijanje kolimisanog snopa neutrona kroz horizontalni kanal reaktora; neutroskog monohromatora; goniometra i elektronskih uredjaja za merenja i registrovanje rezultata. Ovaj izvestaj sadrzi detaljan opis i seme neutronskog difraktometra sa pratecom opremom i elektronskim komponentama.

  14. An IMU-to-Body Alignment Method Applied to Human Gait Analysis

    Directory of Open Access Journals (Sweden)

    Laura Susana Vargas-Valencia

    2016-12-01

    Full Text Available This paper presents a novel calibration procedure as a simple, yet powerful, method to place and align inertial sensors with body segments. The calibration can be easily replicated without the need of any additional tools. The proposed method is validated in three different applications: a computer mathematical simulation; a simplified joint composed of two semi-spheres interconnected by a universal goniometer; and a real gait test with five able-bodied subjects. Simulation results demonstrate that, after the calibration method is applied, the joint angles are correctly measured independently of previous sensor placement on the joint, thus validating the proposed procedure. In the cases of a simplified joint and a real gait test with human volunteers, the method also performs correctly, although secondary plane errors appear when compared with the simulation results. We believe that such errors are caused by limitations of the current inertial measurement unit (IMU technology and fusion algorithms. In conclusion, the presented calibration procedure is an interesting option to solve the alignment problem when using IMUs for gait analysis.

  15. Evaluation of Arm and Shoulder Mobility and Strength after Modified Radical Mastectomy and Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Blomqvist, Lennart; Stark, Birgit; Engler, Natacha; Malm, Maj [Karolinska Inst., Stockholm (Sweden). Dept. of Physiotherapy Center for Surgical Sciences

    2004-04-01

    Seventy-five women, of whom 30 had received postoperative radiotherapy, were tested for range of motion (ROM) and shoulder strength with a goniometer and an isokinetic device (Orthotron II), respectively. On the individual level, irradiated patients exhibited significantly reduced range of motion (varying from p<0.05 to p<0.001) for all movements compared with the non-operated side. In contrast, in the non-irradiated patients only flexion was significantly reduced (p<0.05). The same individual pattern was evident for shoulder strength where all movements except external rotation were significantly reduced in irradiated patients (varying from p<0.05 to p<0.001). Non-irradiated patients exhibited a significant reduction in shoulder strength for flexion and abduction (p<0.05), whereas other movements were less affected. The observed differences in ROM and strength were less pronounced when analyzed on a group level, but were still significant for ROM (p<0.001) for flexion and abduction. Group level analysis also showed reduced shoulder strength for all movements but only rotation was significantly (p<0.01) impaired.

  16. Experience in use of optical theodolite for machine construction

    Science.gov (United States)

    Shereshevskiy, L. M.

    1984-02-01

    An optical theodolite, an instrument of small size and weight featuring a high-precision horizontal dial, was successfully used in production of forging and pressing equipment at the Voronezh plant. Such a TV-1 theodolite, together with a contact-type indicating device and a mechanism for centering the machined part, is included in a turret goniometer for angular alignment and control of cutting operations. Its micrometer has 1 inch scale divisions, the instrument is designed to give readings with a high degree of stability and reproducibility with the standard deviation of one measurement not exceeding 5 inches. It is particularly useful in production of parts with variable spacing and cross section of grooves or slots, including curvilinear ones. With a universal adapter plate on which guide prisms and an interchangeable gauge pin are mounted, this theodolite can also be used in production of large bevel gears: the same instrument for a wide range of gear sizes, diametral pitches, and tooth profiles. Using the maximum of standard components, this theodolite can be easily assembled at any manufacturing plant.

  17. In situ macromolecular crystallography using microbeams

    International Nuclear Information System (INIS)

    Axford, Danny; Owen, Robin L.; Aishima, Jun; Foadi, James; Morgan, Ann W.; Robinson, James I.; Nettleship, Joanne E.; Owens, Raymond J.; Moraes, Isabel; Fry, Elizabeth E.; Grimes, Jonathan M.; Harlos, Karl; Kotecha, Abhay; Ren, Jingshan; Sutton, Geoff; Walter, Thomas S.; Stuart, David I.; Evans, Gwyndaf

    2012-01-01

    A sample environment for mounting crystallization trays has been developed on the microfocus beamline I24 at Diamond Light Source. The technical developments and several case studies are described. Despite significant progress in high-throughput methods in macromolecular crystallography, the production of diffraction-quality crystals remains a major bottleneck. By recording diffraction in situ from crystals in their crystallization plates at room temperature, a number of problems associated with crystal handling and cryoprotection can be side-stepped. Using a dedicated goniometer installed on the microfocus macromolecular crystallography beamline I24 at Diamond Light Source, crystals have been studied in situ with an intense and flexible microfocus beam, allowing weakly diffracting samples to be assessed without a manual crystal-handling step but with good signal to noise, despite the background scatter from the plate. A number of case studies are reported: the structure solution of bovine enterovirus 2, crystallization screening of membrane proteins and complexes, and structure solution from crystallization hits produced via a high-throughput pipeline. These demonstrate the potential for in situ data collection and structure solution with microbeams

  18. Nanostructured wear resistant coating for reversible cultivator shovels: An experimental investigation

    Energy Technology Data Exchange (ETDEWEB)

    Dave, V., E-mail: vdaditya1000@gmail.com [Department of Electrical Engineering,College of Technology and Engineerin, MPUAT Udaipur, 313001,India (India); Rao, G. P., E-mail: ragrao38@gmail.com; Tiwari, G. S., E-mail: tiwarigsin@yahoo.com [Department of Farm Machinery and Power Engineering, MPUAT Udaipur, 313001,India (India); Sanger, A., E-mail: amitsangeriitr@gmail.com; Kumar, A., E-mail: 01ashraj@gmail.com; Chandra, R., E-mail: ramesfic@gmail.com [Institute Instrumentation Centre, Indian Institute of Technology Roorkee, Roorkee 247667 (India)

    2016-04-13

    Cultivator, one of the agriculture farm tool, extensively suffers from the wear problem. In this paper, we report nanostructured chromium nitrite (CrN) coating for the cultivator shovels to mitigate wear problem. The (CrN) coating was developed using DC magnetron sputtering technique at 200 °C. The structural, morphological, hydrophobic and wear properties were investigated using X-ray diffractometer, scanning electron microscope, contact angle goniometer and custom designed soil bin assembly. The XRD reveals that the deposited coating was polycrystalline in nature with cubic structure. Also, The deposited coating was found to be anti wear resistant as well as hydrophobic in nature. The gravimetric wear for the coating developed at 200 °C coated was found out to be 8.15 gm and for non coated it was 14.48 gm tested for 100 hrs. The roughness of the coating plays an important role in determining the hydrophobicity of the coated film. Roughness and contact angle measured for 200 °C coated shovel was found out to be 11.17 nm and 105 ° respectively.

  19. In situ macromolecular crystallography using microbeams

    Energy Technology Data Exchange (ETDEWEB)

    Axford, Danny; Owen, Robin L.; Aishima, Jun [Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE (United Kingdom); Foadi, James [Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE (United Kingdom); Imperial College, London SW7 2AZ (United Kingdom); Morgan, Ann W.; Robinson, James I. [University of Leeds, Leeds LS9 7FT (United Kingdom); Nettleship, Joanne E.; Owens, Raymond J. [Research Complex at Harwell, Rutherford Appleton Laboratory R92, Didcot, Oxfordshire OX11 0DE (United Kingdom); Moraes, Isabel [Imperial College, London SW7 2AZ (United Kingdom); Fry, Elizabeth E.; Grimes, Jonathan M.; Harlos, Karl; Kotecha, Abhay; Ren, Jingshan; Sutton, Geoff; Walter, Thomas S. [University of Oxford, Roosevelt Drive, Oxford OX3 7BN (United Kingdom); Stuart, David I. [Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE (United Kingdom); University of Oxford, Roosevelt Drive, Oxford OX3 7BN (United Kingdom); Evans, Gwyndaf, E-mail: gwyndaf.evans@diamond.ac.uk [Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE (United Kingdom)

    2012-04-17

    A sample environment for mounting crystallization trays has been developed on the microfocus beamline I24 at Diamond Light Source. The technical developments and several case studies are described. Despite significant progress in high-throughput methods in macromolecular crystallography, the production of diffraction-quality crystals remains a major bottleneck. By recording diffraction in situ from crystals in their crystallization plates at room temperature, a number of problems associated with crystal handling and cryoprotection can be side-stepped. Using a dedicated goniometer installed on the microfocus macromolecular crystallography beamline I24 at Diamond Light Source, crystals have been studied in situ with an intense and flexible microfocus beam, allowing weakly diffracting samples to be assessed without a manual crystal-handling step but with good signal to noise, despite the background scatter from the plate. A number of case studies are reported: the structure solution of bovine enterovirus 2, crystallization screening of membrane proteins and complexes, and structure solution from crystallization hits produced via a high-throughput pipeline. These demonstrate the potential for in situ data collection and structure solution with microbeams.

  20. UA9 Results from Crystal Collimation Tests in the SPS & Future Strategy

    CERN Document Server

    Scandale, W

    2013-01-01

    The UA9 Collaboration, with support by EuCARD-AccNet, is investigating how bent crystals, used as primary collimators, could assist and improve the collimation process in modern hadron colliders like the LHC. From 2009 onwards the UA9 Collaboration has successfully tested silicon crystals at the SPS, performing measurements of the associated collimation efficiency by means of various methods and detectors. This report presents the main UA9 results, obtained with protons and Pb ions at 120 GeV/c and 270 GeV/c per charge from 2009 to 2012, which indicate that crystal assisted collimation is well mastered and understood. Specifically, reduced loss rates were demonstrated close to the crystal, as well as in a downstream off-momentum region, and, indeed, all around the ring. In addition, the importance of the crystal miscut angle was elucidated and a first industrial goniometer compliant with LHC specifications has become available. At the end of the report, the near-term plan for LHC crystal collimation is descri...

  1. Investigation of Electrospun Poly Vinyl Alcohol Fibers Towards the Development of Manufacturable Wound Dressings

    Science.gov (United States)

    Vora, Asad

    Polymers such as polyvinyl alcohol, chitosan, and starch have excellent bio-compatible and bio-degradable properties. Their applications in drug delivery, wound dressings, artificial cartilage materials have increased dramatically due to their much sought-after renewable and biological properties. Hence, polyvinyl alcohol has been chosen for this study to test the feasibility of polyvinyl alcohol nanofibers towards the manufacturable wound dressings. Polyvinyl alcohol nanofibers are prepared via electrospinning technique, where different wt% polyvinyl alcohol solutions are prepared. The fibers were optimized by varying important electrospninning parameters which include voltage applied, the collector-needle distance and flow rate. Morphology and structure of the electrospun fibers are analysed using scanning electron microscopy and fourier transform infrared respectively. The diameter of fibers obtained was found to be in the range of 100 nm-160 nm. Thermal stability was examined using DSC and TGA characterization technique and fibers are found to be stable up to 220oC. Finally, each weight sample of PVA fibers are analysed by goniometer for wettability and is found to be hydrophilic.

  2. Nanostructured wear resistant coating for reversible cultivator shovels: An experimental investigation

    International Nuclear Information System (INIS)

    Dave, V.; Rao, G. P.; Tiwari, G. S.; Sanger, A.; Kumar, A.; Chandra, R.

    2016-01-01

    Cultivator, one of the agriculture farm tool, extensively suffers from the wear problem. In this paper, we report nanostructured chromium nitrite (CrN) coating for the cultivator shovels to mitigate wear problem. The (CrN) coating was developed using DC magnetron sputtering technique at 200 °C. The structural, morphological, hydrophobic and wear properties were investigated using X-ray diffractometer, scanning electron microscope, contact angle goniometer and custom designed soil bin assembly. The XRD reveals that the deposited coating was polycrystalline in nature with cubic structure. Also, The deposited coating was found to be anti wear resistant as well as hydrophobic in nature. The gravimetric wear for the coating developed at 200 °C coated was found out to be 8.15 gm and for non coated it was 14.48 gm tested for 100 hrs. The roughness of the coating plays an important role in determining the hydrophobicity of the coated film. Roughness and contact angle measured for 200 °C coated shovel was found out to be 11.17 nm and 105 ° respectively.

  3. Nanostructured wear resistant coating for reversible cultivator shovels: An experimental investigation

    Science.gov (United States)

    Dave, V.; Rao, G. P.; Tiwari, G. S.; Sanger, A.; Kumar, A.; Chandra, R.

    2016-04-01

    Cultivator, one of the agriculture farm tool, extensively suffers from the wear problem. In this paper, we report nanostructured chromium nitrite (CrN) coating for the cultivator shovels to mitigate wear problem. The (CrN) coating was developed using DC magnetron sputtering technique at 200 °C. The structural, morphological, hydrophobic and wear properties were investigated using X-ray diffractometer, scanning electron microscope, contact angle goniometer and custom designed soil bin assembly. The XRD reveals that the deposited coating was polycrystalline in nature with cubic structure. Also, The deposited coating was found to be anti wear resistant as well as hydrophobic in nature. The gravimetric wear for the coating developed at 200 °C coated was found out to be 8.15 gm and for non coated it was 14.48 gm tested for 100 hrs. The roughness of the coating plays an important role in determining the hydrophobicity of the coated film. Roughness and contact angle measured for 200 °C coated shovel was found out to be 11.17 nm and 105 ° respectively.

  4. Status of UA9, the Crystal Collimation Experiment in the SPS

    CERN Document Server

    Scandale, W

    2011-01-01

    UA9 was operated at the CERN-SPS for more than two years to investigate the feasibility of halo collimation with bent crystals. Silicon crystals 2 mm long with bending angles of about 170 μrad were used as primary collimators. The crystal collimation process was steadily achieved through channeling, with high efficiency. The crystal orientation was easily set and optimized with an installed goniometer that has an angular accuracy of about ± 10 μrad. In channeling orientation, the loss rate of the halo particles interacting with the crystal is reduced by half an order of magnitude, whilst the residual off momentum halo escaping from the crystal-collimator area is reduced by a factor two to five. The crystal channeling efficiency of about 75% is reasonably consistent with simulations and with single pass data collected in the extracted proton beam of the SPS North Experimental Area. The accumulated observations, shown in this paper, support our expectation that the coherent deflection of the beam halo by a b...

  5. First occurrence of ningyoite in the USSR

    Energy Technology Data Exchange (ETDEWEB)

    Belova, L N; Gorshkov, A I; Ivanova, O A [AN SSSR, Moscow. Inst. Geologii Rudnykh Mestorozhdenij, Petrografii, Mineralogii i Geokhimii

    1978-01-01

    A tetravalent uranium phosphate-ningyoite for the first time has been discovered in stratum epigenetic uranium deposit in the USSR. Application of electron microscopy combined with microdiffraction and micro X-ray spectral analysis promoted the discovery. The investigation has been carried out with an aid of electron microscopy supplied with the ''Kevex Ray'' goniometer and microprobe attachment. Spendle-shaped crystals of ningyoite, their fractures and more seldom-stellar concretions are discovered in finely dispersed mineral mixture of sample, selected from grey-green sandstone with spots of red iron hydrooxides. Electron cell of the crystals corresponds to the one of ningyoite, described by Muto. The discovered law of declinations, characterizes one of the spatial groups with base - centered lattice of the rhombic crystallographic system Cmmm; C222; Cmm 2, Cm2m. P, U, Ca elements have been determined in tha ratio P:U:Ca=2; 0,6-0,9; 1,4-1,4. The clarified ningyoite formula appears in the form of Casub(2-x)Usub(x)(PO/sub 4/)/sub 2/xH/sub 2/O where x <=1.

  6. Correlations among visual analogue scale, neck disability index, shoulder joint range of motion, and muscle strength in young women with forward head posture.

    Science.gov (United States)

    Shin, Young Jun; Kim, Won Hyo; Kim, Seong Gil

    2017-08-01

    This study investigated the correlation between the neck disability index (NDI) and visual analogue scale (VAS), which are indicators of neck pain, shoulder joint range of motion (ROM), and muscle strength in women with a slight forward head posture. This study was carried out on 42 female college students attending Uiduk University in Gyeongju, Korea. The neck pain and disability index for each subject was measured using VAS and NDI, respectively. Two physiotherapists measured the shoulder joint ROM and muscle strengths of the subjects using a goniometer and a dynamometer, respectively. External rotation, internal rotation, and abduction of the shoulder joint were measured for each subject. A significant negative correlation between neck pain and shoulder joint ROM in external rotation and the muscle strength of the shoulder joint in abduction was found in the subjects. In addition, a significant positive correlation was observed between ROM in external rotation and muscle strength in abduction. This study showed a significant negative correlation between neck pain and ROM in external rotation as well as between neck pain and the muscle strength in abduction.

  7. Research of electrosurgical unit with novel antiadhesion composite thin film for tumor ablation: Microstructural characteristics, thermal conduction properties, and biological behaviors.

    Science.gov (United States)

    Shen, Yun-Dun; Lin, Li-Hsiang; Chiang, Hsi-Jen; Ou, Keng-Liang; Cheng, Han-Yi

    2016-01-01

    The objective of this study was to use surface functionalization to evaluate the antiadhesion property and thermal injury effects on the liver when using a novel electrosurgical unit with nanostructured-doped diamond-like carbon (DLC-Cu) thin films for tumor ablations. The physical and chemical properties of DLC-Cu thin films were characterized by contact angle goniometer, scanning electron microscope, and transmission electron microscope. Three-dimensional (3D) hepatic models were reconstructed using magnetic resonance imaging to simulate a clinical electrosurgical operation. The results indicated a significant increase of the contact angle on the nanostructured DLC-Cu thin films, and the antiadhesion properties were also observed in an animal model. Furthermore, the surgical temperature in the DLC-Cu electrosurgical unit was found to be significantly lower than the untreated unit when analyzed using 3D models and thermal images. In addition, DLC-Cu electrodes caused a relatively small injury area and lateral thermal effect. The results indicated that the nanostructured DLC-Cu thin film coating reduced excessive thermal injury and tissue adherence effect in the liver. © 2015 Wiley Periodicals, Inc.

  8. Membrane electrode assembly with doped polyaniline interlayer for proton exchange membrane fuel cells under low relative humidity conditions

    Energy Technology Data Exchange (ETDEWEB)

    Cindrella, L. [Fuel Cell Research Lab, Engineering Technology Department, Arizona State University, Mesa, AZ 85212 (United States); Department of Chemistry, National Institute of Technology, Tiruchirappalli, Tamil Nadu 620015 (India); Kannan, A.M. [Fuel Cell Research Lab, Engineering Technology Department, Arizona State University, Mesa, AZ 85212 (United States)

    2009-09-05

    A membrane electrode assembly (MEA) was designed by incorporating an interlayer between the catalyst layer and the gas diffusion layer (GDL) to improve the low relative humidity (RH) performance of proton exchange membrane fuel cells (PEMFCs). On the top of the micro-porous layer of the GDL, a thin layer of doped polyaniline (PANI) was deposited to retain moisture content in order to maintain the electrolyte moist, especially when the fuel cell is working at lower RH conditions, which is typical for automotive applications. The surface morphology and wetting angle characteristics of the GDLs coated with doped PANI samples were examined using FESEM and Goniometer, respectively. The surface modified GDLs fabricated into MEAs were evaluated in single cell PEMFC between 50 and 100% RH conditions using H{sub 2} and O{sub 2} as reactants at ambient pressure. It was observed that the MEA with camphor sulfonic acid doped PANI interlayer showed an excellent fuel cell performance at all RH conditions including that at 50% at 80 C using H{sub 2} and O{sub 2}. (author)

  9. Systematic errors in VLF direction-finding of whistler ducts

    International Nuclear Information System (INIS)

    Strangeways, H.J.; Rycroft, M.J.

    1980-01-01

    In the previous paper it was shown that the systematic error in the azimuthal bearing due to multipath propagation and incident wave polarisation (when this also constitutes an error) was given by only three different forms for all VLF direction-finders currently used to investigate the position of whistler ducts. In this paper the magnitude of this error is investigated for different ionospheric and ground parameters for these three different systematic error types. By incorporating an ionosphere for which the refractive index is given by the full Appleton-Hartree formula, the variation of the systematic error with ionospheric electron density and latitude and direction of propagation is investigated in addition to the variation with wave frequency, ground conductivity and dielectric constant and distance of propagation. The systematic bearing error is also investigated for the three methods when the azimuthal bearing is averaged over a 2 kHz bandwidth. This is found to lead to a significantly smaller bearing error which, for the crossed-loops goniometer, approximates the bearing error calculated when phase-dependent terms in the receiver response are ignored. (author)

  10. Macroion induced dehydration of weak polyelectrolyte brushes

    Science.gov (United States)

    Zheng, Zhongli; Zhu, Y. Elaine

    2014-03-01

    The interaction of macroions, including polyelectrolytes, DNAs, and proteins, with polymer and cellular surfaces is critically related to many biomolecular activities, such as protein adsorption and DNA hybridization at probe surfaces. In an experimental approach to examine the macroion electrostatic interaction with a polymer surface while minimizing the long-debated hydrophobic interaction, we study the interaction of molybdenum-based inorganic polyoxometalate (POM) nanoclusters carrying 42 negative charges as model hydrophilic macroions with surface-tethered poly-2-vinylpyridine (P2VP) brushes immersed in aqueous solutions. By AFM, QCM, and contact goniometer, we have observed the collapse of P2VP chains by adding POM macroions at a constant pH. Surprisingly, added POM macroions can cause the shift of swollen-to-collapse transition pH to a lower value, in contrast to the shift to high pH value by adding simple monovalent salts. At sufficiently high POM concentration, a stable POM-P2VP composite layer, showing little dependence on solution pH and additional salts, can be formed, suggesting a simple route to construct meso-porous polymer membranes.

  11. Serial single molecule electron diffraction imaging: diffraction background of superfluid helium droplets

    Science.gov (United States)

    Zhang, Jie; He, Yunteng; Lei, Lei; Alghamdi, Maha; Oswalt, Andrew; Kong, Wei

    2017-08-01

    In an effort to solve the crystallization problem in crystallography, we have been engaged in developing a method termed "serial single molecule electron diffraction imaging" (SS-EDI). The unique features of SS-EDI are superfluid helium droplet cooling and field-induced orientation: together the two features constitute a molecular goniometer. Unfortunately, the helium atoms surrounding the sample molecule also contribute to a diffraction background. In this report, we analyze the properties of a superfluid helium droplet beam and its doping statistics, and demonstrate the feasibility of overcoming the background issue by using the velocity slip phenomenon of a pulsed droplet beam. Electron diffraction profiles and pair correlation functions of ferrocene-monomer-doped droplets and iodine-nanocluster-doped droplets are presented. The timing of the pulsed electron gun and the effective doping efficiency under different dopant pressures can both be controlled for size selection. This work clears any doubt of the effectiveness of superfluid helium droplets in SS-EDI, thereby advancing the effort in demonstrating the "proof-of-concept" one step further.

  12. Evaluation of Arm and Shoulder Mobility and Strength after Modified Radical Mastectomy and Radiotherapy

    International Nuclear Information System (INIS)

    Blomqvist, Lennart; Stark, Birgit; Engler, Natacha; Malm, Maj

    2004-01-01

    Seventy-five women, of whom 30 had received postoperative radiotherapy, were tested for range of motion (ROM) and shoulder strength with a goniometer and an isokinetic device (Orthotron II), respectively. On the individual level, irradiated patients exhibited significantly reduced range of motion (varying from p<0.05 to p<0.001) for all movements compared with the non-operated side. In contrast, in the non-irradiated patients only flexion was significantly reduced (p<0.05). The same individual pattern was evident for shoulder strength where all movements except external rotation were significantly reduced in irradiated patients (varying from p<0.05 to p<0.001). Non-irradiated patients exhibited a significant reduction in shoulder strength for flexion and abduction (p<0.05), whereas other movements were less affected. The observed differences in ROM and strength were less pronounced when analyzed on a group level, but were still significant for ROM (p<0.001) for flexion and abduction. Group level analysis also showed reduced shoulder strength for all movements but only rotation was significantly (p<0.01) impaired

  13. Spectral BRDF measurements of metallic samples for laser processing applications

    International Nuclear Information System (INIS)

    Vitali, L; Fustinoni, D; Gramazio, P; Niro, A

    2015-01-01

    The spectral bidirectional reflectance distribution function (BRDF) of metals plays an important role in industrial processing involving laser-surface interaction. In particular, in laser metal machining, absorbance is strongly dependent on the radiation incidence angle as well as on finishing and contamination grade of the surface, and in turn it can considerably affect processing results. Very recently, laser radiation is also used to structure metallic surfaces, in order to produce many particular optical effects, ranging from a high level polishing to angular color shifting. Of course, full knowledge of the spectral BRDF of these structured layers makes it possible to infer reflectance or color for any irradiation and viewing angles. In this paper, we present Vis-NIR spectral BRDF measurements of laser-polished metallic, opaque, flat samples commonly employed in such applications. The resulting optical properties seem to be dependent on the atmospheric composition during the polishing process in addition to the roughness. The measurements are carried out with a Perkin Elmer Lambda 950 double-beam spectrophotometer, equipped with the Absolute Reflectance/Transmittance Analyzer (ARTA) motorized goniometer. (paper)

  14. The structural analysis of zinc borate glass by laboratory EXAFS and X-ray diffraction measurements

    International Nuclear Information System (INIS)

    Kajinami, Akihiko; Harada, Yasushi; Inoue, Shinsuke; Deki, Shigehito; Umesaki, Norimasa

    1999-01-01

    The structure of zinc borate glass has been investigated by laboratory EXAFS and X-ray diffraction measurement as preliminary investigations for the detailed study in SPring-8. The zinc borate glass was prepared in the range from 40 to 65 mol% of zinc oxide content. The X-ray diffraction was measured by horizontal θ-θ goniometer with 60 kV and 300 mA output of Mo target. The EXAFS of zinc borate glass was measured by laboratory EXAFS system with 20 kV, 100 mA output of Mo target for the K absorption edge of zinc atom. From the X-ray diffraction and the EXAFS measurements, it is found that the zinc ion is surrounded by four oxygen atoms and formed a tetrahedral structure whose (Zn-O) distance is about 2 A and that the structure is unchanged with the zinc oxide content. The diffraction data show that the neighboring structure of boron atom transforms from BO 4 tetrahedra to BO 3 tetragonal planar structure with increasing of the zinc oxide content. (author)

  15. High-vacuum chamber for the irradiation of targets

    International Nuclear Information System (INIS)

    Krimmel, E.; Dullnig, H.

    1975-01-01

    The high vacuum chamber for irradiating targets with X-rays, electron or ion beams is connected to a magazine storage vessel for the targets through a loading duct which can be evacuated. This duct is traversed by a carriage transporting a magazine to the irradiation position. The duct can be closed by a closing valve. Inside the chamber there is a grip attached to a swivel arm which takes a frame with a target from the magazine, or vice versa, and moves it into the irradiation position. This means that the chamber must always be kept at a constant internal pressure. The swiveling shaft for the swivel arm and the transport pinion of the carriage in addition are magnetically coupled to drive shafts located outside the chamber, which obviates the need for any seals. The grip may also deposit the frame on a goniometer, which allows the target to be aligned in the irradiation position. In addition, the measuring probes used to record the amount of reflected radiation are installed in the chamber under electrically insulated conditions relative to the chamber. (DG/RF) [de

  16. Geometry of X-ray based measurement of residual strain at desired penetration depth

    Energy Technology Data Exchange (ETDEWEB)

    Morawiec, A. [Polish Academy of Sciences, Institute of Metallurgy and Materials Science, Krakow (Poland)

    2017-10-15

    X-ray based measurement of residual lattice strains at chosen penetration depth is one of the methods for investigating strain inhomogeneities in near-surface layers of polycrystalline materials. The measurement relies on determining shifts of Bragg peaks for various directions of the scattering vector with respect to the specimen. At each of these directions, to reach a given the penetration depth, a proper specimen orientation is required. The task of determining such orientations, albeit elementary, is quite intricate. The existing literature describes only partial solutions with unspecified domains of application, which fail if applied to beyond the domains. Therefore, geometric aspects of the measurement are analyzed in details. Explicit bounds on measurement parameters are given. The equation fundamental for the procedure is solved with respect to specimen orientations. For a given direction of the scattering vector, there are generally four different specimen orientations leading to the same penetration depth. This simple fact (overlooked in previous analyses) can be used for improving reliability of measurement results. Analytical formulas for goniometer angles representing these orientations are provided. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  17. Immediate effect of a single anteroposterior talus mobilization on dorsiflexion range of motion in participants with orthopedic dysfunction of the ankle and foot.

    Science.gov (United States)

    Teixeira, Luciana Mundim; Pires, Tatiana; Silva, Rafael Duarte; de Resende, Marcos Antônio

    2013-01-01

    The purpose of this study was to determine the immediate effects of a single anteroposterior mobilization of the talus on the active dorsiflexion range of motion (ROM) in participants with different orthopedic foot and ankle injuries. This study included 30 male and female participants aged 18 to 50 years with unilateral orthopedic foot and ankle dysfunction. All participants underwent 3 sets of active dorsiflexion ROM measurement in both ankles. Measurements included baseline, post-first treatment, and post-second treatment values. Participants received either joint mobilization or manual contact (control) on the affected ankle. Active dorsiflexion ROM was assessed using a biplanar goniometer with participants in the prone position and 90° of knee flexion. Both groups (joint mobilization and manual contact) showed increased active dorsiflexion ROM. However, the mean difference of dorsiflexion measurements before and after mobilization was greater than before and after control treatment. A single session of articular mobilization of the talus did not significantly increase dorsiflexion ROM in participants with orthopedic dysfunctions of the ankle and foot compared with a manual contact procedure. Copyright © 2013 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  18. Quantitative and Isolated Measurement of Far-Field Light Scattering by a Single Nanostructure

    Science.gov (United States)

    Kim, Donghyeong; Jeong, Kwang-Yong; Kim, Jinhyung; Ee, Ho-Seok; Kang, Ju-Hyung; Park, Hong-Gyu; Seo, Min-Kyo

    2017-11-01

    Light scattering by nanostructures has facilitated research on various optical phenomena and applications by interfacing the near fields and free-propagating radiation. However, direct quantitative measurement of far-field scattering by a single nanostructure on the wavelength scale or less is highly challenging. Conventional back-focal-plane imaging covers only a limited solid angle determined by the numerical aperture of the objectives and suffers from optical aberration and distortion. Here, we present a quantitative measurement of the differential far-field scattering cross section of a single nanostructure over the full hemisphere. In goniometer-based far-field scanning with a high signal-to-noise ratio of approximately 27.4 dB, weak scattering signals are efficiently isolated and detected under total-internal-reflection illumination. Systematic measurements reveal that the total and differential scattering cross sections of a Au nanorod are determined by the plasmonic Fabry-Perot resonances and the phase-matching conditions to the free-propagating radiation, respectively. We believe that our angle-resolved far-field measurement scheme provides a way to investigate and evaluate the physical properties and performance of nano-optical materials and phenomena.

  19. Proprioceptive Ability of Fencing and Table Tennis Practioners

    Directory of Open Access Journals (Sweden)

    Bańkosz Ziemowit

    2014-09-01

    Full Text Available Purpose. The aim of the study was to compare the spatial component of proprioceptive ability by reproducing a upper limb movement typical in table tennis and fencing. Methods. The research comprised 41 young males of which 12 were table tennis players, 14 fencers, and 15 not involved in any competitive sports as a control. The experiment was based on assessing the precision of pronation and supination of the forearm at the elbow joint in recreating a set movement range by use of a goniometer. Results and conclusions. The results point to a higher level of proprioceptive ability in fencers and table tennis players than the control group but only in respect to the tasks executed with the dominant limb. This is inferred to be the result from the specific character of both sports (i.e. the intensive use of one limb and the consequent laterality of that limb causing higher sensitivity and proprioception. This may provide a link between swordplay, table tennis, and the level of proprioception. The research methodology used herein may be useful in monitoring fencing training. Although not unequivocally statistically significant, the results indicate the potential for further research in this area.

  20. Temporal dynamics of sand dune bidirectional reflectance characteristics for absolute radiometric calibration of optical remote sensing data

    Science.gov (United States)

    Coburn, Craig A.; Logie, Gordon S. J.

    2018-01-01

    Attempts to use pseudoinvariant calibration sites (PICS) for establishing absolute radiometric calibration of Earth observation (EO) satellites requires high-quality information about the nature of the bidirectional reflectance distribution function (BRDF) of the surfaces used for these calibrations. Past studies have shown that the PICS method is useful for evaluating the trend of sensors over time or for the intercalibration of sensors. The PICS method was not considered until recently for deriving absolute radiometric calibration. This paper presents BRDF data collected by a high-performance portable goniometer system to develop a temporal BRDF model for the Algodones Dunes in California. By sampling the BRDF of the sand surface at similar solar zenith angles to those normally encountered by EO satellites, additional information on the changing nature of the surface can improve models used to provide absolute radiometric correction. The results demonstrated that the BRDF of a reasonably simple sand surface was complex with changes in anisotropy taking place in response to changing solar zenith angles. For the majority of observation and illumination angles, the spectral reflectance anisotropy observed varied between 1% and 5% in patterns that repeat around solar noon.

  1. The Multivariate Largest Lyapunov Exponent as an Age-Related Metric of Quiet Standing Balance

    Directory of Open Access Journals (Sweden)

    Kun Liu

    2015-01-01

    Full Text Available The largest Lyapunov exponent has been researched as a metric of the balance ability during human quiet standing. However, the sensitivity and accuracy of this measurement method are not good enough for clinical use. The present research proposes a metric of the human body’s standing balance ability based on the multivariate largest Lyapunov exponent which can quantify the human standing balance. The dynamic multivariate time series of ankle, knee, and hip were measured by multiple electrical goniometers. Thirty-six normal people of different ages participated in the test. With acquired data, the multivariate largest Lyapunov exponent was calculated. Finally, the results of the proposed approach were analysed and compared with the traditional method, for which the largest Lyapunov exponent and power spectral density from the centre of pressure were also calculated. The following conclusions can be obtained. The multivariate largest Lyapunov exponent has a higher degree of differentiation in differentiating balance in eyes-closed conditions. The MLLE value reflects the overall coordination between multisegment movements. Individuals of different ages can be distinguished by their MLLE values. The standing stability of human is reduced with the increment of age.

  2. Reviewing effectiveness of ankle assessment techniques for use in robot-assisted therapy.

    Science.gov (United States)

    Zhang, Mingming; Davies, T Claire; Zhang, Yanxin; Xie, Shane

    2014-01-01

    This article provides a comprehensive review of studies that investigated ankle assessment techniques to better understand those that can be used in the real-time monitoring of rehabilitation progress for implementation in conjunction with robot-assisted therapy. Seventy-six publications published between January 1980 and August 2013 were selected based on eight databases. They were divided into two main categories (16 qualitative and 60 quantitative studies): 13 goniometer studies, 18 dynamometer studies, and 29 studies about innovative techniques. A total of 465 subjects participated in the 29 quantitative studies of innovative measurement techniques that may potentially be integrated in a real-time monitoring device, of which 19 studies included less than 10 participants. Results show that qualitative ankle assessment methods are not suitable for real-time monitoring in robot-assisted therapy, though they are reliable for certain patients, while the quantitative methods show great potential. The majority of quantitative techniques are reliable in measuring ankle kinematics and kinetics but are usually available only for use in the sagittal plane. Limited studies determine kinematics and kinetics in all three planes (sagittal, transverse, and frontal) where motions of the ankle joint and the subtalar joint actually occur.

  3. Vertical force and wrist deviation angle when using a walker to stand up and sit down.

    Science.gov (United States)

    Leung, Cherng-Yee; Yeh, Po-Chan

    2011-08-01

    Research investigating walkers suggests that safety and assistance for the elderly with weak lower limbs were important. However, the relationship between the use of a walker and the upper limbs has received little investigation. Standing up and sitting down are important daily activities. Therefore, the aim of this study was to explore wrist deviation and vertical force among elderly individuals using a walker for assistance to stand up and sit down. In total, 64 elderly volunteers (M age = 80.22, SD = 9.36) were enrolled. Data were obtained from four load cells and a twin-axis wrist goniometer. Wrist deviation and vertical force were examined when participants used a walker with horizontal handles to assist in standing up and sitting down. Significant wrist angle deviation occurred with the use of a walker, with dorsiflexion of the right hand greater than that of the left. Males exerted significantly greater vertical force. In the sitting position, greater ulnar deviation was seen among experienced walker users, whereas during standing, experienced users exhibited greater dorsiflexion. The horizontal handles of most marketed walkers may cause user wrist deviations, suggesting researchers should pursue improvements in walker design.

  4. Real-time knee adduction moment feedback training using an elliptical trainer.

    Science.gov (United States)

    Kang, Sang Hoon; Lee, Song Joo; Ren, Yupeng; Zhang, Li-Qun

    2014-03-01

    The external knee adduction moment (EKAM) is associated with knee osteoarthritis (OA) in many aspects including presence, progression, and severity of knee OA. Despite of its importance, there is a lack of EKAM estimation methods that can provide patients with knee OA real-time EKAM biofeedback for training and clinical evaluations without using a motion analysis laboratory. A practical real-time EKAM estimation method, which utilizes kinematics measured by a simple six degree-of-freedom goniometer and kinetics measured by a multi-axis force sensor underneath the foot, was developed to provide real-time feedback of the EKAM to the patients during stepping on an elliptical trainer, which can potentially be used to control and alter the EKAM. High reliability (ICC(2,1): 0.9580) of the real-time EKAM estimation method was verified through stepping trials of seven subjects without musculoskeletal disorders. Combined with advantages of elliptical trainers including functional weight-bearing stepping and mitigation of impulsive forces, the real-time EKAM estimation method is expected to help patients with knee OA better control frontal plane knee loading and reduce knee OA development and progression.

  5. Measurement of the tendon of the biceps brachii after tenotomy: study on cadavers

    Directory of Open Access Journals (Sweden)

    Anderson Cunha Machado

    2015-08-01

    Full Text Available ABSTRACTOBJECTIVE: To evaluate the influence of elbow and forearm range of motion on the distal excursion of the long head of the biceps (LHB. METHODS: The distal excursion of the LHB after tenotomy of the shoulders of eight cadavers was ascertained by measuring the distance between a point marked out on the LHB, 3 cm from the anterolateral border of the acromion, and its position at different degrees of elbow flexion, using a digital pachymeter. The measurements at elbow flexion of 135°, 90°, 45° and 0° were noted: these angles were established using a goniometer. The measurements were made with the forearm in neutral, supination and pronation positions. RESULTS: Differences between the mean measurements of the distal excursion of the LHB (total sample were observed between the degrees of elbow flexion ( p< 0.01. However, no statistical differences were observed between the different forearm positions, between the sides, genders and ages of the cadavers studied. CONCLUSION: Progressive extension of the elbow caused progressive distal excursion of the LHB, but without interference in the forearm position, gender, side or age of the cadavers studied.

  6. Effects of the magnetic field on the structure of materials

    International Nuclear Information System (INIS)

    Nakajima, Tetsuo

    1984-02-01

    This is a report of the ''Meeting on the effects of a magnetic field on the structure of materials'' held at KEK, Japan. The purpose of the Meeting was to study the diffraction of SR X-ray in a magnetic field. It was found that the effects of a magnetic field have been seen in various substnaces. The effects are due to the Zeeman effect, the Lamor diamagnetism, the Landau diamagnetism, the Meissner effect and the polarization effect. The topics discussed at the Meeting were the structure study of biological specimens by field orientation, the study of cell structure by field orientation, the phase transition under a strong pulse field, the behavior of high molecular liquid crystal in a magnetic field, the change of the f-electron density of the Tb 3+ ions in Tb IG in a magnetic field at low temperature, an electromagnet loaded on a goniometer and an in-situ observation system for the structure of magnetic domain, the control of structural phase transition by a magnetic field, the use of synchrotron orbit radiation for the structural analysis of random systems, and the field effect on chemical reactions. (Kato, T.)

  7. Time-of-flight neutron diffractometer for monocrystal study

    International Nuclear Information System (INIS)

    Anan'ev, B.N.; Balagurov, A.M.; Barabash, I.P.; Georgiu, Z.; Shibaev, V.D.

    1979-01-01

    The design of a neutron diffractometer is discussed. It is used for structural analysis of single crystals on the basis of time-of-flight measurements. The diffractometer is positioned along the axis of a beam of the IBR-30 pulse reactor, its average power is 29 kW. The mechanical part of the diffractometer consists of a massive foundation with a threeaxial goniometer, a rotatable platform with a collimator and a 3 He counter. The flowsheet of a control unit is given, which is used to position the rotatable platform of the diffractometer. The control unit includes a 14 digic binary counter for rotation angle recording, a parallel-to-series converter, a control signal shaper, two position shift registers, and a servo mechanism. The accuracy of diffraction maxima is evaluated. It is found that the ratio D(t)sup(1/2)/t (D(t) is a time dispersion of diffraction maxima, t is total time-of-flight time), which characterize the resolution of the diffractometer, is equal to 0.5% at the Bragg angle Q=45 deg and the neutron wavelength Λ=1 A

  8. DEVELOPMENT OF NEXT-GENERATION DETECTORS AND INSTRUMENTATION FOR PHOTOELECTRON SPECTROSCOPY, DIFFRACTION AND HOLOGRAPHY

    International Nuclear Information System (INIS)

    Charles S. Fadley, Principal Investigator

    2005-01-01

    We have developed a new multichannel detector for use in photoelectron spectroscopy (as well as other types of high-count-rate spectroscopy) that will operate at rates of up to 1 GHz. Such detectors are crucial to the full utilization of the high-brightness radiation generated by third-generation synchrotron radiation sources. In addition, new software and hardware has been developed to permit rapidly and accurately scanning photoelectron spectra that will be accumulated in as little as a 200 micros. A versatile next-generation sample goniometer permitting equally rapid scanning of specimen angles or photon energies for angle-resolved photoemission studies, photoelectron diffraction, and photoelectron holography measurements, and cooling to below 10K has also been designed and constructed. These capabilities have been incorporated into a unique photoelectron spectrometer/diffractometer at the Advanced Light Source of the Lawrence Berkeley National Laboratory; this experimental system includes ultrahigh energy resolution, in situ rotation, variable polarization, and optional spin detection. This overall system is now being used in studies of a variety of problems including magnetic metals and oxides; metal/metal, metal/metal oxide, and metal-oxide/metal-oxide multilayers; and systems exhibiting giant and colossal magnetoresistance

  9. Design and development of a device to measure the deformities of clubfoot.

    Science.gov (United States)

    Khas, Kanwaljit S; Pandey, Pulak M; Ray, Alok R

    2015-03-01

    Clubfoot describes a range of foot abnormalities usually present at birth, in which the foot of a baby is twisted out of shape or position. In order to develop an effective treatment plan for clubfoot and/or assess the extent to which existing interventions are successful, medical practitioners need to be able to accurately measure the nature and extent of the deformity. This is typically performed using a goniometer. However, this device is only able to measure one dimension at a time. As such, a complete assessment of the condition of a foot can be extremely burdensome and time-consuming. This article describes a new device that can quickly and efficiently take several measurements on feet of various sizes and shapes. The use of this device was verified by measuring the deformities of real clubfeet. A silicone rubber clubfoot model was also used in this study to clearly illustrate the effectiveness with which the proposed device can measure the various deformities of clubfoot. It is envisaged that the use of this device will significantly reduce the time and effort orthopedists require to measure clubfoot deformities and develop and assess treatment plans. © IMechE 2015.

  10. Towards automated diffraction tomography: Part I-Data acquisition

    International Nuclear Information System (INIS)

    Kolb, U.; Gorelik, T.; Kuebel, C.; Otten, M.T.; Hubert, D.

    2007-01-01

    The ultimate aim of electron diffraction data collection for structure analysis is to sample the reciprocal space as accurately as possible to obtain a high-quality data set for crystal structure determination. Besides a more precise lattice parameter determination, fine sampling is expected to deliver superior data on reflection intensities, which is crucial for subsequent structure analysis. Traditionally, three-dimensional (3D) diffraction data are collected by manually tilting a crystal around a selected crystallographic axis and recording a set of diffraction patterns (a tilt series) at various crystallographic zones. In a second step, diffraction data from these zones are combined into a 3D data set and analyzed to yield the desired structure information. Data collection can also be performed automatically, with the recent advances in tomography acquisition providing a suitable basis. An experimental software module has been developed for the Tecnai microscope for such an automated diffraction pattern collection while tilting around the goniometer axis. The module combines STEM imaging with diffraction pattern acquisition in nanodiffraction mode. It allows automated recording of diffraction tilt series from nanoparticles with a size down to 5 nm

  11. Laboratory and In-Flight In-Situ X-ray Imaging and Scattering Facility for Materials, Biotechnology and Life Sciences

    Science.gov (United States)

    2003-01-01

    We propose a multifunctional X-ray facility for the Materials, Biotechnology and Life Sciences Programs to visualize formation and behavior dynamics of materials, biomaterials, and living organisms, tissues and cells. The facility will combine X-ray topography, phase micro-imaging and scattering capabilities with sample units installed on the goniometer. This should allow, for the first time, to monitor under well defined conditions, in situ, in real time: creation of imperfections during growth of semiconductors, metal, dielectric and biomacromolecular crystals and films, high-precision diffraction from crystals within a wide range of temperatures and vapor, melt, solution conditions, internal morphology and changes in living organisms, tissues and cells, diffraction on biominerals, nanotubes and particles, radiation damage, also under controlled formation/life conditions. The system will include an ultrabright X-ray source, X-ray mirror, monochromator, image-recording unit, detectors, and multipurpose diffractometer that fully accommodate and integrate furnaces and samples with other experimental environments. The easily adjustable laboratory and flight versions will allow monitoring processes under terrestrial and microgravity conditions. The flight version can be made available using a microsource combined with multilayer or capillary optics.

  12. Hip joint mobility in dancers: preliminary report.

    Science.gov (United States)

    Drężewska, Marlena; Gałuszka, Renata; Sliwiński, Zbigniew

    2012-01-01

    The aim of this study was to evaluate the impact of dancing on hip joint mobility and to assess the relationship between active movements of the hips and injuries among dancers, which may be important in planning rehabilitation in this group. The sample comprised 49 dancers (37 women and 12 men) aged 15 to 32 years. The participants were the professional dancers of the Kielce Dance Theatre and members of two youth jazz dance teams from the Kielce Dance Theatre. The active range of motion of the hips was measured in three planes using a goniometer in order to assess the influence of dance training on hip joint mobility. A questionnaire-based survey was also conducted. The range of flexion, extension and external rotation was significantly greater in the group of long-time dancers (p <0.05). There was a significantly greater range of flexion, abduction and external rotation in previously injured hip joints (p<0.05). 1. Injuries to hip joints in dancers may result in increased ranges of motion, which may lead to disturbances of joint stability. 2. Being a long-time dancer and the female gender were associated with an increased range of hip joint motion.

  13. Restricted neck mobility in children with chronic tension type headache: a blinded, controlled study.

    Science.gov (United States)

    Fernández-Mayoralas, Daniel M; Fernández-de-las-Peñas, César; Palacios-Ceña, Domingo; Cantarero-Villanueva, Irene; Fernández-Lao, Carolina; Pareja, Juan A

    2010-10-01

    The main purpose of this study was to analyze the differences in neck mobility between children with chronic tension type headache (CTTH) and healthy children, and to determine the influence of cervical mobility on headache intensity, frequency and duration. Fifty children, 13 boys and 37 girls (mean age 8.5 ± 1.6 years) with CTTH associated to peri-cranial tenderness (IHS 2.3.1) and 50 age- and sex matched children without headache (13 boys, 37 girls, mean age 8.5 ± 1.8 years, P = 0.955) participated. Cervical range of motion (CROM) was objectively assessed with a cervical goniometer by an assessor blinded to the children's condition. Children completed a headache diary for 4 weeks to confirm the diagnosis. Children with CTTH showed decreased CROM as compared to children without headache for flexion (z = -6.170; P 0.125) or gender (P > 0.250) did not influence CROM in either children with CTTH or without headache. Current results support the hypothesis that the cervical spine should be explored in children with headache. Further research is also needed to clearly define the potential role of the cervical spine in the genesis or maintenance of CTTH.

  14. A Synergy-Based Optimally Designed Sensing Glove for Functional Grasp Recognition.

    Science.gov (United States)

    Ciotti, Simone; Battaglia, Edoardo; Carbonaro, Nicola; Bicchi, Antonio; Tognetti, Alessandro; Bianchi, Matteo

    2016-06-02

    Achieving accurate and reliable kinematic hand pose reconstructions represents a challenging task. The main reason for this is the complexity of hand biomechanics, where several degrees of freedom are distributed along a continuous deformable structure. Wearable sensing can represent a viable solution to tackle this issue, since it enables a more natural kinematic monitoring. However, the intrinsic accuracy (as well as the number of sensing elements) of wearable hand pose reconstruction (HPR) systems can be severely limited by ergonomics and cost considerations. In this paper, we combined the theoretical foundations of the optimal design of HPR devices based on hand synergy information, i.e., the inter-joint covariation patterns, with textile goniometers based on knitted piezoresistive fabrics (KPF) technology, to develop, for the first time, an optimally-designed under-sensed glove for measuring hand kinematics. We used only five sensors optimally placed on the hand and completed hand pose reconstruction (described according to a kinematic model with 19 degrees of freedom) leveraging upon synergistic information. The reconstructions we obtained from five different subjects were used to implement an unsupervised method for the recognition of eight functional grasps, showing a high degree of accuracy and robustness.

  15. A Synergy-Based Optimally Designed Sensing Glove for Functional Grasp Recognition

    Directory of Open Access Journals (Sweden)

    Simone Ciotti

    2016-06-01

    Full Text Available Achieving accurate and reliable kinematic hand pose reconstructions represents a challenging task. The main reason for this is the complexity of hand biomechanics, where several degrees of freedom are distributed along a continuous deformable structure. Wearable sensing can represent a viable solution to tackle this issue, since it enables a more natural kinematic monitoring. However, the intrinsic accuracy (as well as the number of sensing elements of wearable hand pose reconstruction (HPR systems can be severely limited by ergonomics and cost considerations. In this paper, we combined the theoretical foundations of the optimal design of HPR devices based on hand synergy information, i.e., the inter-joint covariation patterns, with textile goniometers based on knitted piezoresistive fabrics (KPF technology, to develop, for the first time, an optimally-designed under-sensed glove for measuring hand kinematics. We used only five sensors optimally placed on the hand and completed hand pose reconstruction (described according to a kinematic model with 19 degrees of freedom leveraging upon synergistic information. The reconstructions we obtained from five different subjects were used to implement an unsupervised method for the recognition of eight functional grasps, showing a high degree of accuracy and robustness.

  16. Effect of a physiotherapy rehabilitation program on knee osteoarthritis in patients with different pain intensities.

    Science.gov (United States)

    Abdel-Aziem, Amr Almaz; Soliman, Elsadat Saad; Mosaad, Dalia Mohammed; Draz, Amira Hussin

    2018-02-01

    [Purpose] To examine the effect of physiotherapy rehabilitation program on moderate knee osteoarthritis in patients with different pain intensities. [Subjects and Methods] Sixty subjects (37 men and 23 women) with moderate knee osteoarthritis participated in the current study. Randomization software was used to select the participating subjects' numbers from the clinic records. They were classified into three groups according to pain intensity: mild, moderate, and severe pain groups. All groups underwent a standard set of pulsed electromagnetic field, ultrasound, stretching exercises, and strengthening exercises. Pain intensity, knee range of motion, knee function, and isometric quadriceps strength were evaluated using the visual analogue scale, universal goniometer, Western Ontario and McMaster Universities osteoarthritis index, and Jamar hydraulic dynamometer, respectively. The evaluation was performed before and after a 4-week rehabilitation program. [Results] All groups showed significant differences in pain intensity, knee range of motion, isometric quadriceps strength, and knee function. The score change in moderate pain group was significantly greater than those in mild and severe pain groups. [Conclusion] Pain intensity is one of the prominent factors that are responsible for the improvement of knee osteoarthritis. Consequently, pain intensity should be considered during rehabilitation of knee osteoarthritis.

  17. Wire rod coating process of gas diffusion layers fabrication for proton exchange membrane fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Kannan, A.M.; Sadananda, S.; Parker, D.; Munukutla, L. [Electronic Systems Department, Arizona State University, 7001 E Williams Field Road, Mesa, AZ 85212 (United States); Wertz, J. [Hollingsworth and Vose Co., A.K. Nicholson Research Lab, 219 Townsend Road West Groton, MA 01472 (United States); Thommes, M. [Quantachrome Instruments, 1900 Corporate Drive, Boynton Beach, FL 33426 (United States)

    2008-03-15

    Gas diffusion layers (GDLs) were fabricated using non-woven carbon paper as a macro-porous layer substrate developed by Hollingsworth and Vose Company. A commercially viable coating process was developed using wire rod for coating micro-porous layer by a single pass. The thickness as well as carbon loading in the micro-porous layer was controlled by selecting appropriate wire thickness of the wire rod. Slurry compositions with solid loading as high as 10 wt.% using nano-chain and nano-fiber type carbons were developed using dispersion agents to provide cohesive and homogenous micro-porous layer without any mud-cracking. The surface morphology, wetting characteristics and pore size distribution of the wire rod coated GDLs were examined using FESEM, Goniometer and Hg porosimetry, respectively. The GDLs were evaluated in single cell PEMFC under various operating conditions (temperature and RH) using hydrogen and air as reactants. It was observed that the wire rod coated micro-porous layer with 10 wt.% nano-fibrous carbon based GDLs showed the highest fuel cell performance at 85 C using H{sub 2} and air at 50% RH, compared to all other compositions. (author)

  18. HIGH RESOLUTION MICROTOMOGRAPHY FOR DENSITY AND SPATIAL INFORMATION ABOUT WOOD STRUCTURES.

    Energy Technology Data Exchange (ETDEWEB)

    ILLMAN,B.

    1999-07-22

    Microtomography has successfully been used to characterize loss of structural integrity of wood. Tomographic images were generated with the newly developed third generation x-ray computed microtomography (XCMT) instrument at the X27A beamline at the National Synchrotron Light Source (NSLS). The beamline is equipped with high-flux x-ray monochromator based on multilayer optics developed for this application. The sample is mounted on a translation stage with which to center the sample rotation, a rotation stage to perform the rotation during data collection and a motorized goniometer head for small alignment motions. The absorption image is recorded by a single-crystal scintillator, an optical microscope and a cooled CCD array detector. Data reconstruction has provided three-dimensional geometry of the heterogeneous wood matrix in microtomographic images. Wood is a heterogeneous material composed of long lignocellulose vessels. Although wood is a strong natural product, fungi have evolved chemical systems that weaken the strength properties of wood by degrading structural vessels. Tomographic images with a resolution of three microns were obtained nonintrusively to characterize the compromised structural integrity of wood. Computational tools developed by Lindquist et al (1996) applied to characterize the microstructure of the tomographic volumes.

  19. Tribological Behaviors of Graphene and Graphene Oxide as Water-Based Lubricant Additives for Magnesium Alloy/Steel Contacts

    Directory of Open Access Journals (Sweden)

    Hongmei Xie

    2018-01-01

    Full Text Available The tribological behaviors of graphene and graphene oxide (GO as water-based lubricant additives were evaluated by use of a reciprocating ball-on-plate tribometer for magnesium alloy-steel contacts. Three sets of test conditions were examined to investigate the effect of concentration, the capacity of carrying load and the endurance of the lubrication film, respectively. The results showed that the tribological behaviors of water can be improved by adding the appropriate graphene or GO. Compared with pure deionized water, 0.5 wt.% graphene nanofluids can offer reduction of friction coefficient by 21.9% and reduction of wear rate by 13.5%. Meanwhile, 0.5 wt.% GO nanofluids were found to reduce the friction coefficient and wear rate up to 77.5% and 90%, respectively. Besides this, the positive effect of the GO nanofluids was also more pronounced in terms of the load-carrying capacity and the lubrication film endurance. The wear mechanisms have been tentatively proposed according to the observation of the worn surfaces by field emission scanning electron microscope-energy dispersive spectrometer (FESEM-EDS and Raman spectrum as well as the wettability of the nanofluids on the magnesium alloy surface by goniometer.

  20. Tribological Behaviors of Graphene and Graphene Oxide as Water-Based Lubricant Additives for Magnesium Alloy/Steel Contacts.

    Science.gov (United States)

    Xie, Hongmei; Jiang, Bin; Dai, Jiahong; Peng, Cheng; Li, Chunxia; Li, Quan; Pan, Fusheng

    2018-01-29

    The tribological behaviors of graphene and graphene oxide (GO) as water-based lubricant additives were evaluated by use of a reciprocating ball-on-plate tribometer for magnesium alloy-steel contacts. Three sets of test conditions were examined to investigate the effect of concentration, the capacity of carrying load and the endurance of the lubrication film, respectively. The results showed that the tribological behaviors of water can be improved by adding the appropriate graphene or GO. Compared with pure deionized water, 0.5 wt.% graphene nanofluids can offer reduction of friction coefficient by 21.9% and reduction of wear rate by 13.5%. Meanwhile, 0.5 wt.% GO nanofluids were found to reduce the friction coefficient and wear rate up to 77.5% and 90%, respectively. Besides this, the positive effect of the GO nanofluids was also more pronounced in terms of the load-carrying capacity and the lubrication film endurance. The wear mechanisms have been tentatively proposed according to the observation of the worn surfaces by field emission scanning electron microscope-energy dispersive spectrometer (FESEM-EDS) and Raman spectrum as well as the wettability of the nanofluids on the magnesium alloy surface by goniometer.

  1. Atom-probe field-ion microscope for the study of the interaction of impurity atoms or alloying elements with defects

    International Nuclear Information System (INIS)

    Wagner, A.; Hall, T.M.; Seidman, D.N.

    1976-10-01

    A time-of-flight (TOF) atom-probe field-ion microscope (FIM) designed for the study of defects is described. This atom probe features: (1) a variable magnification internal-image-intensification system; (2) a liquid-helium goniometer stage; (3) a low-energy (less than or equal 3 keV) gas-ion gun for in-situ irradiations; (4) an ultra-high vacuum (approximately 3.10 -10 torr) chamber; (5) a high vacuum (approximately 10 -6 torr) specimen-exchange device; (6) a Chevron ion detector; and (7) an eight-channel digital timer with a +-10 nsec resolution for measuring the TOFs. The entire process of applying the evaporation pulse to the specimen, measuring the voltages, and analyzing the TOF data is controlled by a computer. With this system we can record and analyze 600 TOFmin. Results on unirradiated specimens of molybdenum, tungsten, W/25 at. % Re, Mo/1.0 at. % Ti, Mo/1.0 at. % Ti/0.08 at. % Zr and a special low swelling stainless steel alloy (LS1A) demonstrate the instrument's ability to quantitatively determine concentrations at the 5.10 -4 at fr level and to determine their spatial distribution with a resolution of a few angstroms

  2. Report on results concerning development of supermetal technology (FY1999-2000). Development of evaluation technology for formability of super metal (development of evaluation technology for formability of recrystallized microstructured plate); Super metal no gijutsu kaihatsu seika hokokusho (1999 - 2000 nendo). Super metal no seikeisei hyoka gijutsu nado no kaihatsu (bisai saikesshotsububan no seikeisei hyoka gijutsu no kaihatsu)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    In connection with the innovative manufacturing of large base materials having a mesoscopic grain structure by means of technologies for high deformation accumulation control, recovery/recrystallization control, etc., research was conducted on evaluation technology for various characteristics such as formability, with fiscal 2000 results compiled. For the purpose of evaluating average grain size from an optical microscopic photograph of structures, it was judged reasonable to determine the average cut piece length. A device introduced to this development project was a horizontal goniometer capable of ODF (crystallite orientation distribution function)/pole figure measurement, qualitative analysis, and residual stress measurement. With warm rolling performed by controlling both material temperature of 7475 based alloys and roll temperature, thermally stable micro sub-grain structures were obtained. As a result of ODF analysis of this warm-rolled material, it was found that a {beta} orientation group existed very sharply in the area from the sheet surface to the center planar part of the thickness. The grain refinement of 5083 based alloys using a warm rolling method was also successful, with its ODF analysis revealing that the accumulation of the {beta} orientation group was very high as in the 7475 based warm-rolled materials. (NEDO)

  3. A study of the picostructure of sputtered ZrN films

    International Nuclear Information System (INIS)

    Perry, A.J.; Schaffer, J.P.; Brunner, J.; Sproul, W.D.

    1991-01-01

    Stoichiometric zirconium nitride films deposited onto cemented carbide and stainless steel substrates as a function of the applied substrate bias were studied by X-ray diffraction (XRD Bragg-Brentano goniometer) and positron annihilation spectroscopy (PAS). Microhardness and color measurements were also carried out. The results at low bias levels show that the crystal lattice has no deviant behavior in the strain distribution or lattice parameters; such differences which are observed in the latter are due to the X-ray elastic constants. Shear stresses are found on the (h00) family of planes and probably on the (hhh) family at bias levels more negative than -70 V. The microhardness and residual stress are then constant. The PAS data indicate that the vacancy defect fraction is below the limit of detection at bias levels less negative than approximately -80 V; a low concentration of vacancies exists at more negative bias values. The color of the films is not affected by the bias applied during deposition, and is only slightly affected by annealing when deposited at low bias values. In view of the change in lattice parameters on annealing, it is concluded that the results do not correspond with those expected from the simple ionic model. (orig.)

  4. Flexibility of internal and external glenohumeral rotation of junior female tennis players and its correlation with performance ranking.

    Science.gov (United States)

    Chiang, Ching-Cheng; Hsu, Chih-Chia; Chiang, Jinn-Yen; Chang, Weng-Cheng; Tsai, Jong-Chang

    2016-12-01

    [Purpose] The purpose of this study was to compare the internal and external rotation of the dominant and nondominant shoulders of adolescent female tennis players. The correlation between the shoulder rotation range of motion and the player's ranking was also analyzed. [Subjects and Methods] Twenty-one female junior tennis players who were 13 to 18 years old participated in this study. A standard goniometer was used to measure the internal and external rotation of both glenohumeral joints. The difference in internal and external rotation was calculated as the glenohumeral rotation deficit. The year-end ranking of each player was obtained from the Chinese Taipei Tennis Association. [Results] The internal rotation of the dominant shoulder was significantly smaller than that of the nondominant shoulder. Moreover, player ranking was significantly and negatively correlated with the internal rotation range of motion of both shoulders. On the other hand, the correlations of the internal and external rotation ranges of motion with the age, height, and weight were not significant. [Conclusion] The flexibility of the glenohumeral internal rotation is smaller in the dominant shoulder than of the nondominant shoulder in these junior female tennis players. Flexibility of the glenohumeral internal rotation may be a factor affecting performance in junior female tennis players.

  5. Quantitative spectroscopy of X-ray lines and continua in tokamaks

    International Nuclear Information System (INIS)

    Peacock, N.J.; Lawson, K.D.; Patel, A.; Barnsley, R.; Melnick, I.M.; O'Mullane, M.G.; Singleton, M.A.

    1996-10-01

    Crystal and synthetic multilayer diffractors, deployed either as flat Bragg reflectors, or curved, as in the Johann configuration, are used to study the spectrum of COMPASS-D and other tokamaks in the wavelength region 1-100 A. In this paper we concentrate on the measurement of absolute photon fluxes and the derivation of volume emissivities of the lines and continua in the X-ray region. The sensitivities of these instruments to absolute photon flux have been constructed ab initio from the individual component efficiencies, including published values of the diffractor reflectivities, which have been checked or supplemented by measurements using a double-axis goniometer or from line branching ratios. For these tokamak plasmas where the elemental abundances and effective ion charge are documented, the X-ray continuum intensity itself has been used as a calibration source to derive absolute instrument sensitivity, in reasonable agreement with the ab initio method. In the COMPASS-D tokamak, changes in the effective ion charge state, Z eff , have been derived for different operating conditions, from the absolute intensity of the continuum at ∼4 A. From the irradiances of the line emission, changes in the absolute level of impurities following ''boronisation'' of the vacuum vessel have also been documented. (UK)

  6. COMPARISON BETWEEN POST ISOMETRIC RELAXATION AND RECIPROCAL INHIBITION MANUEVERS ON HAMSTRING FLEXIBILITY IN YOUNG HEALTHY ADULTS: RANDOMIZED CLINICAL TRIAL

    Directory of Open Access Journals (Sweden)

    Agrawal Sonal S

    2016-01-01

    Full Text Available Background & Purpose: Variations in the application of muscle energy technique (MET for increasing the extensibility of muscles have been advocated, but little evidence exists to support the relative merit of a particular approach. This study investigated two types of muscle energy techniques that have been advocated in the osteopathic literature that differ primarily in the muscle group targeted. Aim: To compare the efficacy of Post Isometric Relaxation (PIR and Reciprocal Inhibition (RI on hamstring length in young healthy adults Methodology: Randomized clinical trial 100 college students aged between 18-25 years were included. The subjects were randomly assigned to PIR and RI group. Each group consisted of 50 subjects (25 male, 25 female. Knee extension limitation was measured by using active knee extension test (AKET pre & post-intervention, i.e. after 3 weeks of stretching regimen, with the help of universal full circle goniometer. Results: There was significant improvement in hamstrings flexibility (p=0.000 in both PIR and RI groups. Statistical comparison of the results of both the technique showed that PIR group had greater improvement than the RI group (p=0.000 Conclusion: PIR and RI were both found to be effective in improving hamstring flexibility but, PIR is more effective therapeutic maneuver.

  7. A multi-modal treatment approach for the shoulder: A 4 patient case series

    Directory of Open Access Journals (Sweden)

    Pollard Henry

    2005-09-01

    Full Text Available Abstract Background This paper describes the clinical management of four cases of shoulder impingement syndrome using a conservative multimodal treatment approach. Clinical Features Four patients presented to a chiropractic clinic with chronic shoulder pain, tenderness in the shoulder region and a limited range of motion with pain and catching. After physical and orthopaedic examination a clinical diagnosis of shoulder impingement syndrome was reached. The four patients were admitted to a multi-modal treatment protocol including soft tissue therapy (ischaemic pressure and cross-friction massage, 7 minutes of phonophoresis (driving of medication into tissue with ultrasound with 1% cortisone cream, diversified spinal and peripheral joint manipulation and rotator cuff and shoulder girdle muscle exercises. The outcome measures for the study were subjective/objective visual analogue pain scales (VAS, range of motion (goniometer and return to normal daily, work and sporting activities. All four subjects at the end of the treatment protocol were symptom free with all outcome measures being normal. At 1 month follow up all patients continued to be symptom free with full range of motion and complete return to normal daily activities. Conclusion This case series demonstrates the potential benefit of a multimodal chiropractic protocol in resolving symptoms associated with a suspected clinical diagnosis of shoulder impingement syndrome.

  8. High-performance polyamide thin-film composite nanofiltration membrane: Role of thermal treatment

    Science.gov (United States)

    Liu, Baicang; Wang, Shuai; Zhao, Pingju; Liang, Heng; Zhang, Wen; Crittenden, John

    2018-03-01

    Nanofiltration (NF) membranes have many excellent applications (e.g., removing multivalent ions and pretreating water before reverse osmosis, RO), but their relatively high cost limits their application. Especially in recent years, researchers have paid substantial attention to reducing the cost of NF membranes. In this paper, high-performance NF membranes were fabricated using interfacial polymerization (IP) methods. The polymer concentration, IP solution concentration, and thermal treatment conditions were varied. The synthesized membranes were characterized using scanning electron microscopy (SEM), atomic force microscopy (AFM), a contact angle goniometer, X-ray photoelectron spectroscopy (XPS), attenuated total reflectance fourier transform infrared (ATR-FTIR) spectroscopy, and performance tests. The results show that water flux was significantly improved using a hot-water thermal treatment method. Our fabricated thermal-treated NF membrane had an approximately 15% higher water permeability with a value of 13.6 L/(m2 h bar) than that of the commercially available GE HL membrane with a value of 11.8 L/(m2 h bar). Our membranes had the same MgSO4 rejection as that of the GE HL membrane. We found that the thermal treatment causes the NF membrane surface to be smoother and have a high crosslinking degree.

  9. Morphologies and separation characteristics of polyphenyl sulfone-based solvent resistant nanofiltration membranes: Effect of polymer concentration in casting solution and membrane pretreatment condition

    Energy Technology Data Exchange (ETDEWEB)

    Sani, Nur Aimie Abdullah; Lau, Woei Jye; Ismail, Ahmad Fauzi [Universiti Teknologi Malaysia, Skudai (Malaysia)

    2015-04-15

    The performance of polyphenylsulfone (PPSU) solvent resistant nanofiltration (SRNF)-based flat sheet membranes prepared from phase inversion method was investigated by varying the concentration of polymer in the dope solution and condition of membrane pretreatment process. The membrane properties were characterized by SEM, FTIR, AFM and contact angle goniometer, while their performance was evaluated by measuring methanol flux and rejection of different molecular weight of dyes (ranging from 269 to 1,470 g/mol) in methanol. The experimental results showed that the polymer concentration has great impact not only on the final membrane morphology but also its separation characteristics. Increasing polymer concentration from 17 to 25wt% tended to suppress finger-like structure and more pear-like pores were developed, causing methanol flux to decrease. This can be explained by the decrease in molecular weight cut off (MWCO) of the membrane prepared at high polymer concentration. With respect to the effect of membrane pretreatment conditions, the rejection of membrane was negatively affected with longer immersion period in methanol solution prior to filtration experiment. The variation in membrane rejection can be attributed to the rearrangement of the polymer chain, which results in membrane swelling and/or change of membrane surface hydrophilicity.

  10. Low temperature X-ray diffraction studies of natural gas hydrate samples from the Gulf of Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Rawn, C.J. [Oak Ridge National Laboratory, Oak Ridge, TN (United States). Materials Science and Technology Div.; Sassen, R. [Texas A and M Univ., College Station, TX (United States). Geochemical and Environmental Research Group; Ulrich, S.M.; Phelps, T.J. [Oak Ridge National Laboratory, Oak Ridge, TN (United States). Biosciences Div.; Chakoumakos, B.C. [Oak Ridge National Laboratory, Oak Ridge, TN (United States). Neutron Scattering Science Div.; Payzant, E.A. [Oak Ridge National Laboratory, Oak Ridge, TN (United States). Center for Nanophase Materials Science

    2008-07-01

    Quantitative studies of natural clathrate hydrates are hampered by the difficulties associated with obtaining pristine samples for the sea floor without comprising their integrity. This paper discussed X-ray power diffraction studies conducted to measure natural gas hydrate samples obtained from the Green Canyon in the Gulf of Mexico. Data on the hydrate deposits were initially collected in 2002. The X-ray diffraction data were collected in order to examine the structure 2 (s2) gas hydrates as functions of temperature and time. A diffractometer with a theta-theta goniometer modified with a helium closed cycle refrigerator and temperature controller was used. Aragonite, quartz and halite phases were determined in the decomposed sample. Refined phase fractions for both the ice and the s2 hydrate were obtained as a function of temperature. Results of the study demonstrated that the amount of hydrates decreased with increasing temperatures and amounts of time. Large pieces of the hydrate showed heterogenous ice content. Dissociation rates were higher at lower temperatures. It was concluded that unusual trends observed for the smaller lattice parameter of the hydrates resulted from the formation of ice layers that acted as barriers to the released gases and caused increased isostatic pressures around the hydrate core. 9 refs., 6 figs.

  11. Influences of the cold atmospheric plasma jet treatment on the properties of the demineralized dentin surfaces

    Science.gov (United States)

    Xiaoming, ZHU; Heng, GUO; Jianfeng, ZHOU; Xiaofei, ZHANG; Jian, CHEN; Jing, LI; Heping, LI; Jianguo, TAN

    2018-04-01

    Improvement of the bonding strength and durability between the dentin surface and the composite resin is a challenging job in dentistry. In this paper, a radio-frequency atmospheric-pressure glow discharge (RF-APGD) plasma jet is employed for the treatment of the acid-etched dentin surfaces used for the composite restoration. The properties of the plasma treated dentin surfaces and the resin-dentin interfaces are analyzed using the x-ray photoemission spectroscopy, contact angle goniometer, scanning electron microscope and microtensile tester. The experimental results show that, due to the abundant chemically reactive species existing in the RF-APGD plasma jet under a stable and low energy input operating mode, the contact angle of the plasma-treated dentin surfaces decreases to a stable level with the increase of the atomic percentage of oxygen in the specimens; the formation of the long resin tags in the scattered clusters and the hybrid layers at the resin-dentin interfaces significantly improve the bonding strength and durability. These results indicate that the RF-APGD plasma jet is an effective tool for modifying the chemical properties of the dentin surfaces, and for improving the immediate bonding strength and the durability of the resin-dentin bonding in dentistry.

  12. Single-crystal neutron diffraction at the Australian Replacement Research Reactor

    International Nuclear Information System (INIS)

    Klooster, W.T.

    2001-01-01

    The purpose of the workshop was to: identify the future needs and opportunities for single-crystal neutron diffraction, and specify instrument requirements. important number of experiments. The conclusion of the workshop deliberation was that Australia has a diverse community of users of single-crystal neutron diffraction. A (quasi)-Laue image-plate diffractometer allows the fastest throughput by far, but would exclude an important number of experiments. Most of these could be covered by the additional possibility to locate the image-plate detector on a monochromatic beam. Therefore it was recommend both a white thermal beam and a monochromatic beam (λ= 1 to 2.4 Angstroms) for an image-plate detector. At little additional cost the existing 2TanA instrument could be located semi-permanently on the same monochromatic beam, thus offering three quite different types of single-crystal instruments. Small improvements could be made to the 2TanA instrument to cater for the remaining experiments not suited to an image-plate diffractometer: exchange of the Eulerian cradle for an automated tilt goniometer for extremely bulky sample environment (cryomagnets, large pressure cells), optional larger area detector, analyser crystal. It was recommended that an Instrument Advisory Team will be assembled, and will help in specifying, designing and commissioning the instrument

  13. Electromyographic and cephalometric correlation with the predominant masticatory movement.

    Science.gov (United States)

    Coelho-Ferraz, Maria Julia P; Berzin, Fausto; Amorim, Cesar Ferreira; Romano, Fabio Lourenco; de Paula Queluz, Dagmar

    2010-01-01

    This study aimed to evaluate the chewing muscular dynamics and correlate the side of the masticatory movement that is more vertical and/or more horizontal established by the photomeasurement Masticatory Functional Angle (MFA) to the muscular activity behavior, showed in the surface electromyography and in the radiographic images. Seventeen people were selected of both genders, with the average age of 25 years, without signs or apparent symptoms of masticatory muscular disorders. The teleradiographies were done in lateral norm and surface electromyography of the masseter muscles, anterior portion of temporal and supra-hyoids in rest position and maximal bite. The bite force measured with a metallic transducer that was connected to a force sensor (Strain Gauge) to measure the deformation of the material model SF4 (EMG SYSTEM DO BRASIL). A mandibular goniometer of the EMG System of Brazil was used to measure the opening size. The comparison and correlation were established between the groups with MFA>5 degrees and MFAStudent or test of Mann-Whitney conform the distribution was normal or not, respectively. The results showed significant differences between groups, although without sexual dimorphism, to masseter muscle in maximal bite. In conclusion, the anatomic-physiological aspects of temporomandibular disorders are related to the asymmetrical mandible function.

  14. The Impact of Cranios acral Therapy on Inhibition of Hypertonicity of the Lower Limb in Children with Dipelgia Spastic Cerebral Palsy of 3-8 Years Old

    Directory of Open Access Journals (Sweden)

    Ebrahim Pishyareh

    2001-01-01

    Full Text Available Objective: The purpose of this study was to assess the facilitating impact of craniosacral therapy on inhibition of hypertonicity of the lower limb in children with spastic dipelgic cerebral palsy. Materials & Methods: 100 children with cerebral palsy were studied and 36 children selected, aged 3 to 8 years, were randomly assigned to a control and an experimental group. Muscle tone was assessed using modified Ashworth scale, passive range of motion by goniometer, neurodevelopment level by Bobath scale. All children were Pre-Post-tested with in an interval of three months. Results: A further finding of the analyses revealed that significant reduction was observed in hypertonicity of the hip adductors and the ankle plantar flexors. Significant increase was observed in passive range of motion of the hip abduction and the ankle dorsiflexion. There was found no significant difference of reduction in hypertonicity of the knee flexors, of increase in passive range of motion of the knee extensor, of improvement neurodevelopmental level. Meaningful relationship was observed between reduction hypertonicity of the hip adductors and improvement of the neurodevelopmental level. Conclusion: It should be mentioned that in all above cases the was set at 5%. Implications for clinical O.T. are mentioned.

  15. Performance analysis of photoresistor and phototransistor for automotive’s halogen and xenon bulbs light output

    Science.gov (United States)

    Rammohan, A.; Kumar, C. Ramesh

    2017-11-01

    Illumination of any light is measured using a different kind of calibrated equipment’s available in the market such as a goniometer, spectral radiometer, photometer, Lux meter and camera based systems which directly display the illumination of automotive headlights light distribution in the unit of lux, foot-candles, lumens/sq. ft. and Lambert etc., In this research, we dealt with evaluating the photo resistor or Light Dependent Resistor (LDR) and phototransistor whether it is useful for sensing light patterns of Automotive Halogen and Xenon bulbs. The experiments are conducted during night hours under complete dark space. We have used the headlamp setup available in TATA SUMO VICTA vehicle in the Indian market and conducted the experiments separately for Halogen and Xenon bulbs under low and high beam operations at various degrees and test points within ten meters of distance. Also, we have compared the light intensity of halogen and xenon bulbs to prove the highest light intensity between halogen and Xenon bulbs. After doing a rigorous test with these two sensors it is understood both are good to sensing beam pattern of automotive bulbs and even it is good if we use an array of sensors or a mixed combination of sensors for measuring illumination purposes under perfect calibrations.

  16. Grinding With Diamond Burs and Hydrothermal Aging of a Y-TZP Material: Effect on the Material Surface Characteristics and Bacterial Adhesion.

    Science.gov (United States)

    Dutra, Dam; Pereira, Gkr; Kantorski, K Z; Exterkate, Ram; Kleverlaan, C J; Valandro, L F; Zanatta, F B

    The aim of this study was to evaluate the effect of grinding with diamond burs and low-temperature aging on the material surface characteristics and bacteria adhesion on a yttrium-stabilized tetragonal zirconia polycrystalline (Y-TZP) surface. Y-TZP specimens were made from presintered blocks, sintered as recommended by the manufacturer, and assigned into six groups according to two factors-grinding (three levels: as sintered, grinding with extra-fine diamond bur [25-μm grit], and grinding with coarse diamond bur [181-μm grit]) and hydrothermal aging-to promote low-temperature degradation (two levels: presence/absence). Phase transformation (X-ray diffractometer), surface roughness, micromorphological patterns (atomic force microscopy), and contact angle (goniometer) were analyzed. Bacterial adhesion (colony-forming units [CFU]/biofilm) was quantified using an in vitro polymicrobial biofilm model. Both the surface treatment and hydrothermal aging promoted an increase in m-phase content. Roughness values increased as a function of increasing bur grit sizes. Grinding with a coarse diamond bur resulted in significantly lower values of contact angle (p0.05). Grinding with diamond burs and hydrothermal aging modified the Y-TZP surface properties; however, these properties had no effect on the amount of bacteria adhesion on the material surface.

  17. Accuracy of a Custom Physical Activity and Knee Angle Measurement Sensor System for Patients with Neuromuscular Disorders and Gait Abnormalities

    Directory of Open Access Journals (Sweden)

    Frank Feldhege

    2015-05-01

    Full Text Available Long-term assessment of ambulatory behavior and joint motion are valuable tools for the evaluation of therapy effectiveness in patients with neuromuscular disorders and gait abnormalities. Even though there are several tools available to quantify ambulatory behavior in a home environment, reliable measurement of joint motion is still limited to laboratory tests. The aim of this study was to develop and evaluate a novel inertial sensor system for ambulatory behavior and joint motion measurement in the everyday environment. An algorithm for behavior classification, step detection, and knee angle calculation was developed. The validation protocol consisted of simulated daily activities in a laboratory environment. The tests were performed with ten healthy subjects and eleven patients with multiple sclerosis. Activity classification showed comparable performance to commercially available activPAL sensors. Step detection with our sensor system was more accurate. The calculated flexion-extension angle of the knee joint showed a root mean square error of less than 5° compared with results obtained using an electro-mechanical goniometer. This new system combines ambulatory behavior assessment and knee angle measurement for long-term measurement periods in a home environment. The wearable sensor system demonstrated high validity for behavior classification and knee joint angle measurement in a laboratory setting.

  18. Correlation between movement of the feet and motor function of children with chronic encephalopathy

    Directory of Open Access Journals (Sweden)

    Táubuta Gomes Souza

    Full Text Available Abstract Introduction: Chronic non-progressive encephalopathy (CNPE is one of the most common causes of physical deformities in childhood. It is characterized by non-progressive neuropathological abnormalities of the developing brain, which results in neuromotor impairments and changes in posture and movement. Objective: To evaluate foot deformities in children with CNPE, by measuring the joint amplitude and correlating these measures with the scores of the Gross Motor Function Measure (GMFM-88, using all its five dimensions. Methods: Cross-sectional and descriptive study with a sample of 17 children. The data collection instruments used were manual goniometer and the Gross Motor Function Measure test (GMFM-88. Data were analyzed using the program SPSS version 18, and the Pearson correlation test as a measure of association. Results: Children with chronic encephalopathy and a reduced amplitude motion have lower capacity in motor function. Statistically significant correlation was found for the right dorsiflexion angle (p = 0.023, left dorsiflexion angle (p = 0.019, right inversion (p = 0.040, left inversion (p = 0.034 and left eversion (p = 0.018. There was no statistically significant correlation for the right eversion (p > 0.05. Conclusion: Musculoskeletal disorders associated with CNPE and foot deformities interfere negatively in motor function, compromising the functional performance of these children.

  19. Fabrication of bio-inspired nitinol alloy surface with tunable anisotropic wetting and high adhesive ability.

    Science.gov (United States)

    Tian, Yan L; Zhao, Yue C; Yang, Cheng J; Wang, Fu J; Liu, Xian P; Jing, Xiu B

    2018-10-01

    In this paper, micro/nano-scale structures were fabricated on nitinol alloy (NiTi) to realize tunable anisotropic wetting and high adhesive capability. Laser texturing and silanization process are utilized to change the morphological and chemical properties of substrates. It is noted that these treated substrates exhibit the joint characteristics of anisotropic wetting and high adhesive capability. In order to investigate the influences of laser-texturing and silanization processes on NiTi, these surfaces were evaluated using scanning electron microscope (SEM), a white light confocal microscope, X-ray photoelectron spectroscopy (XPS) and goniometer. The relationship between water volume and anisotropic wetting was also established. From the experimental testing, we can obtain the following conclusions: (1) the anisotropic wetting characterized by the difference between the water contact angles (WCAs) in the vertical and parallel directions ranges from 0° to 20.3°, which is far more than the value of natural rice leaves. (2) the water sliding angles (WSAs) kept stable at 180°, successfully mimicking the adhesive ability of rose petals. (3) the silanization process could strengthen the hydrophobicity but weaken anisotropic wetting. These bio-inspired NiTi surfaces have a tremendous potential applications such as microfluidic devices, bio-mimetic materials fabrication and lab on chip. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Bio-physical characteristics of gastrointestinal mucosa of celiac patients: comparison with control subjects and effect of gluten free diet-

    Directory of Open Access Journals (Sweden)

    Villanacci Vincenzo

    2011-11-01

    Full Text Available Abstract Background Intestinal mucosa is leaky in celiac disease (CD, and this alteration may involve changes in hydrophobicity of the mucus surface barrier in addition to alteration of the epithelial barrier. The aims of our study were i to compare duodenal hydrophobicity as an index of mucus barrier integrity in CD patients studied before (n = 38 and during gluten- free diet (GFD, n = 68, and in control subjects (n = 90, and ii to check for regional differences of hydrophobicity in the gastro-intestinal tract. Methods Hydrophobicity was assessed by measurement of contact angle (CA (Rame Hart 100/10 goniometer generated by a drop of water placed on intestinal mucosal biopsies. Results CA (mean ± SD of distal duodenum was significantly lower in CD patients (56° ± 10° than in control subjects (69° ± 9°, p corpus > rectum > duodenum > oesophagus > ileum. Conclusions We conclude that the hydrophobicity of duodenal mucous layer is reduced in CD patients, and that the resulting decreased capacity to repel luminal contents may contribute to the increased intestinal permeability of CD. This alteration mirrors the severity of the mucosal lesions and is not completely reverted by gluten-free diet. Intestinal hydrophobicity exhibits regional differences in the human intestinal tract.

  1. Effect of Anti-Sticking Nanostructured Surface Coating on Minimally Invasive Electrosurgical Device in Brain.

    Science.gov (United States)

    Cheng, Han-Yi; Ou, Keng-Liang; Chiang, Hsi-Jen; Lin, Li-Hsiang

    2015-10-01

    The purpose of the present study was to examine the extent of thermal injury in the brain after the use of a minimally invasive electrosurgical device with a nanostructured copper-doped diamond-like carbon (DLC-Cu) surface coating. To effectively utilize an electrosurgical device in clinical surgery, it is important to decrease the thermal injury to the adjacent tissues. The surface characteristics and morphology of DLC-Cu thin film was evaluated using a contact angle goniometer, scanning electron microscopy, and atomic force microscopy. Three-dimensional biomedical brain models were reconstructed using magnetic resonance images to simulate the electrosurgical procedure. Results indicated that the temperature was reduced significantly when a minimally invasive electrosurgical device with a DLC-Cu thin film coating (DLC-Cu-SS) was used. Temperatures decreased with the use of devices with increasing film thickness. Thermographic data revealed that surgical temperatures in an animal model were significantly lower with the DLC-Cu-SS electrosurgical device compared to an untreated device. Furthermore, the DLC-Cu-SS device created a relatively small region of injury and lateral thermal range. As described above, the biomedical nanostructured film reduced excessive thermal injury with the use of a minimally invasive electrosurgical device in the brain.

  2. Morphologies and separation characteristics of polyphenyl sulfone-based solvent resistant nanofiltration membranes: Effect of polymer concentration in casting solution and membrane pretreatment condition

    International Nuclear Information System (INIS)

    Sani, Nur Aimie Abdullah; Lau, Woei Jye; Ismail, Ahmad Fauzi

    2015-01-01

    The performance of polyphenylsulfone (PPSU) solvent resistant nanofiltration (SRNF)-based flat sheet membranes prepared from phase inversion method was investigated by varying the concentration of polymer in the dope solution and condition of membrane pretreatment process. The membrane properties were characterized by SEM, FTIR, AFM and contact angle goniometer, while their performance was evaluated by measuring methanol flux and rejection of different molecular weight of dyes (ranging from 269 to 1,470 g/mol) in methanol. The experimental results showed that the polymer concentration has great impact not only on the final membrane morphology but also its separation characteristics. Increasing polymer concentration from 17 to 25wt% tended to suppress finger-like structure and more pear-like pores were developed, causing methanol flux to decrease. This can be explained by the decrease in molecular weight cut off (MWCO) of the membrane prepared at high polymer concentration. With respect to the effect of membrane pretreatment conditions, the rejection of membrane was negatively affected with longer immersion period in methanol solution prior to filtration experiment. The variation in membrane rejection can be attributed to the rearrangement of the polymer chain, which results in membrane swelling and/or change of membrane surface hydrophilicity

  3. Animal-eyeball vs. road-sign retroreflectors.

    Science.gov (United States)

    Greene, Nathaniel R; Filko, Brian J

    2010-01-01

    The retroreflective characteristics of ex-vitro cow and deer eyeballs were compared to those of man-made materials used in road signs and bicycle-style reflectors. Reflected intensities were measured using a goniometer that consists of a green He-Ne laser as the light source, and a photomultiplier tube as the detector. It was found that the best quality road-sign reflector, made from a 200-micron-scale, close-packed array of corner cubes, is approximately six times more efficient than a cow eyeball at returning light in the direction of the incoming beam. Less expensive man-made retroreflectors, utilizing 35-micron glass beads (as in mailbox decals) or millimeter-scale arrays of corner cubes (bicycle-style reflectors) are, however, less efficient than the cow eye. The high quality of animal eyeball optics is evidenced by their extremely tight angular spread (full width half maximum congruent with 1 degrees) of retroreflected intensity about the incident path. Moreover, as the reflector itself is rotated relative to the incident beam, the eyeballs preserve their efficiency of retroreflection better than the man-made materials. Interference-diffraction patterns were observed in the retroreflected beams from the small-scale corner cubes, but were not observed in eyeball retroreflection.

  4. Pulsed Plasma Polymerization of Perfluorooctyl Ethylene for Transparent Hydrophobic Thin Coatings

    International Nuclear Information System (INIS)

    Liu Xiaojun; Wang Lei; Hao Jie; Chu Liqiang

    2015-01-01

    Herein we report on the deposition of transparent hydrophobic thin coatings by radio frequency plasma polymerization (PP) of perfluorooctyl ethylene (PFOE) in both pulsed and continuous wave (CW) modes. The chemical compositions of the resulting PP-PFOE coatings were confirmed by means of Fourier transform infrared spectroscopy (FT-IR) and X-ray photoelectron spectroscopy (XPS). The thicknesses and surface morphologies of the coatings were examined using surface plasmon resonance spectroscopy and atomic force microscopy. The surface wetting properties and optical transmittance were measured using a water contact angle goniometer and UV-vis spectroscopy. The FT-IR and XPS data showed that the PP-PFOE coatings deposited in the pulsed mode had a higher retention of CF 2 groups compared to those from the CW mode. While the water contact angle of the freshly deposited PP-PFOE from the pulsed mode showed a decrease from 120 degrees to 111 degrees in the first two days, it then remained almost unchanged up to 45 days. The UV-vis data indicated that a PP-PFOE coating 30.6 nm thick had a light transmittance above 90% in the UV and visible ranges. The deposition rates under various plasma conditions are also discussed. (paper)

  5. Development of gas diffusion layer using water based carbon slurry for proton exchange membrane fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Lin, J.F.; Liu, X.; Adame, A.; Villacorta, R. [Fuel Cell Research Laboratory, Engineering Technology Department, Arizona State University, Mesa, AZ 85212 (United States); Wertz, J. [Hollingsworth and Vose Co., A.K. Nicholson Research Lab, 219 Townsend Road, West Groton, MA 01472 (United States); Ahmad, R.; Thommes, M. [Quantachrome Instruments, 1900 Corporate Drive, Boynton Beach, FL 33426 (United States); Kannan, A.M., E-mail: amk@asu.ed [Fuel Cell Research Laboratory, Engineering Technology Department, Arizona State University, Mesa, AZ 85212 (United States)

    2011-01-01

    The micro-porous layer of gas diffusion layers (GDLs) was fabricated with the carbon slurry dispersed in water containing sodium dodecyl sulfate (SDS), by wire rod coating process. The aqueous carbon slurry with micelle-encapsulation was highly consistent and stable without losing any homogeneity even after adding polytetrafluoroethylene (PTFE) binder for hundreds of hours. The surface morphology, contact angle and pore size distribution of the GDLs were examined using SEM, Goniometer and Hg Porosimeter, respectively. GDLs fabricated with various SDS concentrations were assembled into MEAs and evaluated in a single cell PEMFC under diverse operating relative humidity (RH) conditions using H{sub 2}/O{sub 2} and H{sub 2}/air as reactants. The peak power density of the single cell using the GDLs with optimum SDS concentration was 1400 and 500 mW cm{sup -2} with H{sub 2}/O{sub 2} and H{sub 2}/air at 90% RH, respectively. GDLs were also fabricated with isopropyl alcohol (IPA) based carbon slurry for fuel cell performance comparison. It was found that the composition of the carbon slurry, specifically SDS concentration played a critical role in controlling the pore diameter as well as the corresponding pore volumes of the GDLs.

  6. Effect of carbon paper substrate of the gas diffusion layer on the performance of proton exchange membrane fuel cell

    Energy Technology Data Exchange (ETDEWEB)

    Lin, J.F. [Fuel Cell Research Lab, Engineering Technology Department, Arizona State University, Mesa, AZ 85212 (United States); Wertz, J. [Hollingsworth and Vose Co., A.K. Nicholson Research Lab, 219 Townsend Road, West Groton, MA 01472 (United States); Ahmad, R.; Thommes, M. [Quantachrome Instruments, 1900 Corporate Drive, Boynton Beach, FL 33426 (United States); Kannan, A.M., E-mail: amk@asu.ed [Fuel Cell Research Lab, Engineering Technology Department, Arizona State University, Mesa, AZ 85212 (United States)

    2010-03-01

    Gas diffusion layers (GDLs) were fabricated using non-woven carbon paper substrates with various thicknesses developed by Hollingsworth and Vose Co. Highly consistent carbon slurry containing Pureblack carbon and vapor grown carbon fiber (3:1 ratio) with 25 wt.% Teflon was prepared by using a dispersion agent, Novec-7300 in isopropyl alcohol. Micro-porous layer was coated by using a fully automated Coatema coating tool with a uniform carbon loading of 2.6-3 mg cm{sup -2} using carbon slurry. The surface morphology, contact angle and pore size distribution of the GDLs were examined using SEM, Goniometer and Hg Porosimeter, respectively. Various cathode GDLs assembled into MEAs were evaluated in a single cell PEMFC under various operating relative humidity (RH) conditions using H{sub 2}/O{sub 2} and H{sub 2}/air as reactants. The peak power density of the single cell using the optimum carbon paper substrate thickness was about 1400 and 700 mW cm{sup -2} with H{sub 2}/O{sub 2} and H{sub 2}/air at 60% RH, respectively. It was found that the pore diameter as well as the corresponding pore volumes of the GDLs played a key role in exhibiting the optimum fuel cell performance.

  7. Mobile Phone-Based Joint Angle Measurement for Functional Assessment and Rehabilitation of Proprioception

    Directory of Open Access Journals (Sweden)

    Quentin Mourcou

    2015-01-01

    Full Text Available Assessment of joint functional and proprioceptive abilities is essential for balance, posture, and motor control rehabilitation. Joint functional ability refers to the capacity of movement of the joint. It may be evaluated thereby measuring the joint range of motion (ROM. Proprioception can be defined as the perception of the position and of the movement of various body parts in space. Its role is essential in sensorimotor control for movement acuity, joint stability, coordination, and balance. Its clinical evaluation is commonly based on the assessment of the joint position sense (JPS. Both ROM and JPS measurements require estimating angles through goniometer, scoliometer, laser-pointer, and bubble or digital inclinometer. With the arrival of Smartphones, these costly clinical tools tend to be replaced. Beyond evaluation, maintaining and/or improving joint functional and proprioceptive abilities by training with physical therapy is important for long-term management. This review aims to report Smartphone applications used for measuring and improving functional and proprioceptive abilities. It identifies that Smartphone applications are reliable for clinical measurements and are mainly used to assess ROM and JPS. However, there is lack of studies on Smartphone applications which can be used in an autonomous way to provide physical therapy exercises at home.

  8. The high-resolution powder diffraction station PO DI STA is ''running'' at Adone

    International Nuclear Information System (INIS)

    Burattini, E.; Simeoni, S.; Cappuccio, G.; Maistrelli, P.

    1992-01-01

    At the end of February 1991, a ''triple-axis'' high-resolution diffractometer for on powder sample measurements with synchrotron radiation was put in operation on the Adone wiggler line BX1 at Frascati. The diffractometer is based on a Seifert goniometer, designed according to our specifications. During the project, particular attention was paid in assuring the highest reliability together with great flexibility in the use. In fact, the diffractometer can also be used in a ''medium resolution'' configuration. For preliminary alignment and data collection, it is possible to operate with a traditional x-ray tube, too. The alignment procedure of the diffractometer to the x-ray beam is very easy. Powder samples can be measured both on the flat holder and on the capillary. An IBM PC computer is used for the instrument actuation and preliminary on-line data collection, while a large software package has been developed for the data analysis performed by a Macintosh IIcx. The instrument performance has been tested with a standard Si sample and quartz and Ni oxide samples. For the two possible resolution configurations, a test on a NiO sample gave FWHM values of 0.16 degree and 0.04 degree, respectively, for the [012] peak

  9. Effects of therapeutic exercise and hydrotherapy on pain severity and knee range of motion in patients with hemophilia: a randomized controlled trial.

    Science.gov (United States)

    Mazloum, Vahid; Rahnama, Nader; Khayambashi, Khalil

    2014-01-01

    Pain and limited range of motion (ROM) are the crucial subsequent results of joint hemorrhages in individuals with bleeding disorders and hemophilia. Exercise interventions are particularly recommended in treatment of such patients. The purpose of this study was to detect the influences of conventional exercise therapy and hydrotherapy on the knee joint complications in patients with hemophilia. A total of 40 patients engaging hemophilia A were randomized into one of three groups: Therapeutic exercise (N = 13), hydrotherapy (N = 14) or control (N = 13). While the first two groups followed their specific programs for 4 weeks, routine life-style was maintained by subjects in the control group in this period. To evaluate the pain level and knee ROM the visual analog scale and standard goniometer were utilized, respectively. The outcome was measured at baseline and after completing the prescribed protocols. Data analysis was performed using one-way analysis of variance and Scheffe statistical tests (P hydrotherapy in comparison to exercise therapy, the difference in ROM improvement was not statistically significant (P > 0.05). Using hydrotherapy in addition to usual rehabilitation training can result in beneficial effect in terms of pain and knee joint ROM. However, it appears that hydrotherapy is more effective in reducing pain.

  10. CORE STABILIZATION PROGRAM AND CONVENTIONAL EXERCISES IN THE PATIENTS WITH LOW BACK PAIN-A COMPARATIVE STUDY

    Directory of Open Access Journals (Sweden)

    Dr. Venkata Naga Prahalada Karnati

    2015-02-01

    Full Text Available Background: Conventional back care exercises are advocated to treat the pain and to strengthen the involved muscles. There will always be the possibility of the pain getting recurred due to disproportionate balance and stability in the muscles. The core stabilization is major trend in rehabilitation. It aims at improving stability during functional activities, balance, flexibility, strength training and effectively manage the pain as well. Methods: Forty patients with chronic Mechanical Low back pain were randomly assigned into control group that received conventional back exercises and SWD (n=20, experimental group received core stabilization and SWD (n=20. Both the groups received SWD, along with conventional back exercises for one-group and core stabilization for the other group 3 days a week for 6 weeks .The treatment outcome was assessed using visual analogue scale, Rolland Morris Disability Questionnaire and Lumbar range of motion by using goniometer. Results: After a 6 week training period the core stabilization group scored significantly higher than the conventional group for VAS (p=0.05 and RMDQ (p=0.05 where as ROM improved higher in conventional group (p=0.05 Conclusion: After the treatment sessions Core stabilization group registered a significant improvement when compared to conventional back care exercises in improving function and in relieving pain.

  11. The effect of short-term upper thoracic self-mobilization using a Kaltenborn wedge on pain and cervical dysfunction in patients with neck pain.

    Science.gov (United States)

    Oh, Hyung-Taek; Hwangbo, Gak

    2018-04-01

    [Purpose] The aim of this study was to determine the effect of short-term self-joint mobilization of the upper spine using a Kaltenborn wedge on the pain and cervical dysfunction of patients with neck pain. [Subjects and Methods] Twenty-seven patients with neck pain were divided into two groups; the self-mobilization group (SMG, n=13) and the self-stretching group (SSG, n=14). The SMG performed upper thoracic self-mobilization and the SSG performed self-stretching exercises as a short-term intervention for a week. To assess the degree of neck pain, the visual analog scale (VAS) was utilized, and to measure the joint range of motion at the flexion-extension, it was compared and analyzed by using the goniometer. [Results] Both SMG and SSG show a significant decrease in the visual analog scale and a significant increase in joint range of motion within the group. In the comparison of groups, there was no significant difference, but it indicated effects on improving the range of motion of extension in SMG. [Conclusion] Self-mobilization of the upper spine, using a Kaltenborn wedge, was useful in alleviating pain in and dysfunction of the cervical spine, and in particular, in improving cervical spine extension in this study.

  12. Nanostructured superhydrophobic polysiloxane coating for high barrier and anticorrosion applications in marine environment.

    Science.gov (United States)

    Arukalam, Innocent O; Oguzie, Emeka E; Li, Ying

    2018-02-15

    The use of epoxy and polyurethane coatings as marine topcoats, have been influenced by their inherent high surface energy property which increases their affinity to water and microorganisms. Thus, their susceptibility to degradation is enhanced. Because of this defect, recently, nanostructured hydrophobic and superhydrophobic polysiloxane coatings are being preferred as topcoats. But the appropriate nanoparticle size and matrix:filler ratio which provide guide for the design of desired topcoats are scarcely available. In view of this, a series of hydrophobic and superhydrophobic coatings were prepared by sol-gel process based on perfluorodecyltrichlorosilane (FDTS), different nanoZnO particles and poly(dimethylsiloxane) (PDMS):nanoZnO ratios. The liquid repellency, surface morphology and roughness of the coatings were conducted by use of contact angle goniometer, field emission scanning electron microscopy and atomic force microscopy, respectively. Additionally, the electrochemical and salt spray corrosion tests were conducted. According to the results, modifications of the coatings showed that anticorrosion performance was considerably influenced by the surface properties which were dependent on nanoZnO size and PDMS:nanoZnO ratio. Remarkably, the optimum effect was observed on the superhydrophobic coating based on 30 nm ZnO and 1:1 ratio. This displayed highest anticorrosion performance, and is therefore recommended as a guide for the design of marine topcoats. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. An apparatus for high speed measurements of small-angle x-ray scattering profiles with a linear position sensitive detector

    International Nuclear Information System (INIS)

    Hashimoto, Takeji; Suehiro, Shoji; Shibayama, Mitsuhiro; Saijo, Kenji; Kawai, Hiromichi

    1981-01-01

    An apparatus for high speed measurements of small-angle X-ray scattering (SAXS) is described. This apparatus utilizes a 12 kW rotating anode X-ray generator, a linear position sensitive proportional counter (multicathode delay line PSPC), and a two-parameter multichannel pulse height analyzer (MCA) with 12 kwords (16 bits/word) memory area available for SAXA intensity data as a function of position (scattering angles) and time slice. The two-parameter MCA is constructed within a microcomputer system, by utilizing its R/W memory for data storage, and the memory incrementing and real-time CRT display is implemented by using two direct memory access (DMA) controllers. The cycle time of the access is about 10 μs. The measuring time for SAXS profiles with this apparatus can be shortened approximately by three orders of magnitude in comparison with the measuring time with SAXS apparatuses utilizing a conventional step-scanning goniometer and a conventional X-ray tube, thus permitting time-resolved analyses of SAXS profiles. Some applications of the apparatus to dynamic SAXS measurements are presented for polymeric systems, the preliminary results of which seem to indicate the possibility of obtaining a new class of data on dynamics in structural transformation, deformation, formation and annihilation in the scale of a few tens to several hundred Angstroms. (author)

  14. Application of the FDK algorithm for multi-slice tomographic image reconstruction; Aplicacao do algoritmo FDK para a reconstrucao de imagens tomograficas multicortes

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Paulo Roberto, E-mail: pcosta@if.usp.b [Universidade de Sao Paulo (IFUSP), SP (Brazil). Inst. de Fisica. Dept. de Fisica Nuclear; Araujo, Ericky Caldas de Almeida [Fine Image Technology, Sao Paulo, SP (Brazil)

    2010-08-15

    This work consisted on the study and application of the FDK (Feldkamp- Davis-Kress) algorithm for tomographic image reconstruction using cone-beam geometry, resulting on the implementation of an adapted multi-slice computed tomography system. For the acquisition of the projections, a rotating platform coupled to a goniometer, an X-ray equipment and a digital image detector charge-coupled device type were used. The FDK algorithm was implemented on a computer with a Pentium{sup R} XEON{sup TM} 3.0 processor, which was used for the reconstruction process. Initially, the original FDK algorithm was applied considering only the ideal physical conditions in the measurement process. Then some artifacts corrections related to the projections measurement process were incorporated. The implemented MSCT system was calibrated. A specially designed and manufactured object with a known linear attenuation coefficient distribution ({mu}(r)) was used for this purpose. Finally, the implemented MSCT system was used for multi-slice tomographic reconstruction of an inhomogeneous object, whose distribution {mu}(r) was unknown. Some aspects of the reconstructed images were analyzed to assess the robustness and reproducibility of the system. During the system calibration, a linear relationship between CT number and linear attenuation coefficients of materials was verified, which validate the application of the implemented multi-slice tomographic system for the characterization of linear attenuation coefficients of distinct several objects. (author)

  15. Reading values of X-ray diffractogram with a digitalizar help

    International Nuclear Information System (INIS)

    Vaquera, A.; Oliveira, N.P. de.

    1985-01-01

    Accuracy of responses obtained through the sketch of deflection peaks in a determined position of the X-ray diffractogram, with hight rotation velocity of the goniometer, is attained with detriment of the resolution. However, the use of a HP 9836A digitalizer connected to HP 9830A minicomputer minimizes reading errors, with the advantage of being faster and nome accurate and precise. Knowing the diffractogram extreme reading values or 'Ad'amplitude (in Θ degrees), it possible to determine the diffratogram angular distance and the distances between the peaks and the diffratogram origin. These values can be expressed in deflection terms (in amgstrons througg Bragg equation. Precision also depends upon the position of the diffratogram in relation to the coordenates established in the digitalizer table. This problem ca be prevented calculating individual distances from each peak to the origin and end of the diffractogram, considering a fixed point on digitalizer table as coordinates of origin, what, however it demands a rather longer response time. The method also permits the utilization of an internal standard, in order to determine the distances in relatIon to the known position of a peak starting from its correspondent deflection value. It is possible to identify the minerals of the analized sample, stocking the deflection values of values of main natural minerals in the minicomputer memory [pt

  16. Relationship Between the Range of Motion and Isometric Strength of Elbow and Shoulder Joints and Ball Velocity in Women Team Handball Players.

    Science.gov (United States)

    Schwesig, René; Hermassi, Souhail; Wagner, Herbert; Fischer, David; Fieseler, Georg; Molitor, Thomas; Delank, Karl-Stefan

    2016-12-01

    Schwesig, R, Hermassi, S, Wagner, H, Fischer, D, Fieseler, G, Molitor, T, and Delank, K-S. Relationship between the range of motion and isometric strength of elbow and shoulder joints and ball velocity in women team handball players. J Strength Cond Res 30(12): 3428-3435, 2016-The aims of this study were to investigate relationships between isometric strength and range of motion (ROM) of shoulder and elbow joints and compare 2 different team handball throwing techniques in women team handball. Twenty highly experienced women team handball players (age: 20.7 ± 2.9 years; body mass: 68.4 ± 6.0 kg; and height: 1.74 ± 0.06 m) participated in this study. The isometric strength (hand-held dynamometer) and ROM (goniometer) of shoulder and elbow joints were measured at the beginning of the preseasonal training. After clinical examination, the subjects performed 3 standing throws with run-up (10 m) and 3 jump throws over a hurdle (0.20 m). The mean ball velocity was calculated from 3 attempts and measured using a radar gun. The results showed that the ball velocity of the standing throw with run-up (vST) was significantly higher than that of the jump throw (vJT) (25.5 ± 1.56 vs. 23.2 ± 1.31 m·s; p handball players.

  17. A comparison between flexible electrogoniometers, inclinometers and three-dimensional video analysis system for recording neck movement.

    Science.gov (United States)

    Carnaz, Letícia; Moriguchi, Cristiane S; de Oliveira, Ana Beatriz; Santiago, Paulo R P; Caurin, Glauco A P; Hansson, Gert-Åke; Coury, Helenice J C Gil

    2013-11-01

    This study compared neck range of movement recording using three different methods goniometers (EGM), inclinometers (INC) and a three-dimensional video analysis system (IMG) in simultaneous and synchronized data collection. Twelve females performed neck flexion-extension, lateral flexion, rotation and circumduction. The differences between EGM, INC, and IMG were calculated sample by sample. For flexion-extension movement, IMG underestimated the amplitude by 13%; moreover, EGM showed a crosstalk of about 20% for lateral flexion and rotation axes. In lateral flexion movement, all systems showed similar amplitude and the inter-system differences were moderate (4-7%). For rotation movement, EGM showed a high crosstalk (13%) for flexion-extension axis. During the circumduction movement, IMG underestimated the amplitude of flexion-extension movements by about 11%, and the inter-system differences were high (about 17%) except for INC-IMG regarding lateral flexion (7%) and EGM-INC regarding flexion-extension (10%). For application in workplace, INC presents good results compared to IMG and EGM though INC cannot record rotation. EGM should be improved in order to reduce its crosstalk errors and allow recording of the full neck range of movement. Due to non-optimal positioning of the cameras for recording flexion-extension, IMG underestimated the amplitude of these movements. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

  18. The Effect of Passive Movement for Paretic Ankle-Foot and Brain Activity in Post-Stroke Patients.

    Science.gov (United States)

    Vér, Csilla; Emri, Miklós; Spisák, Tamás; Berényi, Ervin; Kovács, Kázmér; Katona, Péter; Balkay, László; Menyhárt, László; Kardos, László; Csiba, László

    2016-01-01

    This study aims at investigating the short-term efficacy of the continuous passive motion (CPM) device developed for the therapy of ankle-foot paresis and to investigate by fMRI the blood oxygen level-dependent responses (BOLD) during ankle passive movement (PM). Sixty-four stroke patients were investigated. Patients were assigned into 2 groups: 49 patients received both 15 min manual and 30 min device therapy (M + D), while the other group (n = 15) received only 15 min manual therapy (M). A third group of stroke patients (n = 12) was investigated by fMRI before and immediately after 30 min CPM device therapy. There was no direct relation between the fMRI group and the other 2 groups. All subjects were assessed using the Modified Ashworth Scale (MAS) and a goniometer. Mean MAS decreased, the ankle's mean plantar flexion and dorsiflexion passive range of motion (PROM) increased and the equinovalgus improved significantly in the M + D group. In the fMRI group, the PM of the paretic ankle increased BOLD responses; this was observed in the contralateral pre- and postcentral gyrus, superior temporal gyrus, central opercular cortex, and in the ipsilateral postcentral gyrus, frontal operculum cortex and cerebellum. Manual therapy with CPM device therapy improved the ankle PROM, equinovalgus and severity of spasticity. The ankle PM increased ipsi- and contralateral cortical activation. © 2016 S. Karger AG, Basel.

  19. Auricular Acupressure for Managing Postoperative Pain and Knee Motion in Patients with Total Knee Replacement: A Randomized Sham Control Study

    Directory of Open Access Journals (Sweden)

    Ling-hua Chang

    2012-01-01

    Full Text Available Background. Postoperative pain management remains a significant challenge for all healthcare providers. A randomized controlled trial was conducted to examine the adjuvant effects of auricular acupressure on relieving postoperative pain and improving the passive range of motion in patients with total knee replacement (TKR. Method. Sixty-two patients who had undergone a TKR were randomly assigned to the acupressure group and the sham control group. The intervention was delivered three times a day for 3 days. A visual analog scale (VAS and the Short-Form McGill Pain Questionnaire were used to assess pain intensity. Pain medication consumption was recorded, and the knee motion was measured using a goniometer. Results. The patients experienced a moderately severe level of pain postoperatively (VAS 58.66 ± 20.35 while being on the routine PCA. No differences were found in pain scores between the groups at all points. However, analgesic drug usage in the acupressure group patients was significantly lower than in the sham control group (<0.05, controlling for BMI, age, and pain score. On the 3rd day after surgery, the passive knee motion in the acupressure group patients was significantly better than in the sham control group patients (<0.05, controlling for BMI. Conclusion. The application of auricular acupressure at specific therapeutic points significantly reduces the opioid analgesia requirement and improves the knee motion in patients with TKR.

  20. Bi-directional Reflectance of Icy Surface Analogs: A Dual Approach

    Science.gov (United States)

    Quinones, Juan Manuel; Vides, Christina; Nelson, Robert M.; Boryta, Mark; Mannat, Ken s.

    2018-01-01

    Bi-directional reflectance measurements of analogs for planetary regolith have provided insight into the surface properties of planetary satellites and small bodies. Because Aluminum Oxide (Al2O3) and water ice share a similar hexagonal crystalline structure, the former has been used in laboratory experiments to simulate the regolith of both icy and dusty planetary bodies. By measuring various sizes of well sorted size fractions of Al2O3, the reflectance phase curve and porosity of a planetary regolith can be determined. We have designed an experiment to test the laboratory measurements produced by Nelson et al. (2000). Additionally, we made reflectance measurements for other alkali-halide compounds that could be used for applications beyond astronomy and planetary science.In order to provide an independent check on the Nelson et al. data, we designed an instrument with a different configuration. While both instruments take bidirectional reflectance measurements, our instrument, the Rigid Photometric Goniometer (RPG), is fixed at a phase angle of 5° and detects the scattered light with a photomultiplier tube (PMT). The PMT current is then measured with an electrometer. Following the example of Nelson et al., we measured the bidirectional reflectance of Al2O3 particulate size fractions between 0.1sizes from 20size that provided optimal, or maximum, reflectance for each compound. Our conclusions bring confirmation and clarity to photometric sciences.

  1. Analysis of the reliability and reproducibility of goniometry compared to hand photogrammetry

    Science.gov (United States)

    de Carvalho, Rosana Martins Ferreira; Mazzer, Nilton; Barbieri, Claudio Henrique

    2012-01-01

    Objective: To evaluate the intra- and inter-examiner reliability and reproducibility of goniometry in relation to photogrammetry of hand, comparing the angles of thumb abduction, PIP joint flexion of the II finger and MCP joint flexion of the V finger. Methods: The study included 30 volunteers, who were divided into three groups: one group of 10 physiotherapy students, one group of 10 physiotherapists, and a third group of 10 therapists of the hand. Each examiner performed the measurements on the same hand mold, using the goniometer followed by two photogrammetry software programs; CorelDraw® and ALCimagem®. Results: The results revealed that the groups and the methods proposed presented inter-examiner reliability, generally rated as excellent (ICC 0.998 I.C. 95% 0.995 - 0.999). In the intra-examiner evaluation, an excellent level of reliability was found between the three groups. In the comparison between groups for each angle and each method, no significant differences were found between the groups for most of the measurements. Conclusion: Goniometry and photogrammetry are reliable and reproducible methods for evaluating measurements of the hand. However, due to the lack of similar references, detailed studies are needed to define the normal parameters between the methods in the joints of the hand. Level of Evidence II, Diagnostic Study. PMID:24453594

  2. X-ray diffractometry with spatial resolution

    International Nuclear Information System (INIS)

    Zeiner, K.

    1981-04-01

    X-ray diffractometry is one of the extensively used methods for investigation of the crystalline structure of materials. Line shape and position of a diffracted line are influenced by grain size, deformation and stress. Spatial resolution of one of these specimen characteristics is usually achieved by point-focused X-ray beams and subsequently analyzing different specimen positions. This work uses the method of image reconstruction from projections for the generation of distribution maps. Additional experimental requirements when using a conventional X-ray goniometer are a specimen scanning unit and a computer. The scanning unit repeatedly performs a number of translation steps followed by a rotation step in a fixed X-ray tube/detector (position sensitive detector) arrangement. At each specimen position a diffraction line is recorded using a line-shaped X-ray beam. This network of diffraction lines (showing line resolution) is mathematically converted to a distribution map of diffraction lines and going thus a point resolution. Specimen areas of up to several cm 2 may be analyzed with a linear resolution of 0.1 to 1 mm. Image reconstruction from projections must be modified for generation of ''function-maps''. This theory is discussed and demonstrated by computer simulations. Diffraction line analysis is done for specimen deformation using a deconvolution procedure. The theoretical considerations are experimentally verified. (author)

  3. An on-ice measurement approach to analyse the biomechanics of ice hockey skating.

    Science.gov (United States)

    Buckeridge, Erica; LeVangie, Marc C; Stetter, Bernd; Nigg, Sandro R; Nigg, Benno M

    2015-01-01

    Skating is a fundamental movement in ice hockey; however little research has been conducted within the field of hockey skating biomechanics due to the difficulties of on-ice data collection. In this study a novel on-ice measurement approach was tested for reliability, and subsequently implemented to investigate the forward skating technique, as well as technique differences across skill levels. Nine high caliber (High) and nine low caliber (Low) hockey players performed 30 m forward skating trials. A 3D accelerometer was mounted to the right skate for the purpose of stride detection, with the 2nd and 6th strides defined as acceleration and steady-state, respectively. The activity of five lower extremity muscles was recorded using surface electromyography. Biaxial electro-goniometers were used to quantify hip and knee angles, and in-skate plantar force was measured using instrumented insoles. Reliability was assessed with the coefficient of multiple correlation, which demonstrated moderate (r>0.65) to excellent (r>0.95) scores across selected measured variables. Greater plantar-flexor muscle activity and hip extension were evident during acceleration strides, while steady state strides exhibited greater knee extensor activity and hip abduction range of motion (p<0.05). High caliber exhibited greater hip range of motion and forefoot force application (p<0.05). The successful implementation of this on-ice mobile measurement approach offers potential for athlete monitoring, biofeedback and training advice.

  4. Effects of Ving Tsun Chinese martial art training on musculoskeletal health, balance performance, and self-efficacy in community-dwelling older adults.

    Science.gov (United States)

    Lip, Ryan W T; Fong, Shirley S M; Ng, Shamay S M; Liu, Karen P Y; Guo, X

    2015-03-01

    [Purpose] The aim of this study was to investigate the effects of Ving Tsun (VT) Chinese martial art training on radial bone strength, upper- and lower-limb muscular strength, shoulder joint mobility, balance performance, and self-efficacy in elderly participants. [Subjects and Methods] Twelve seniors voluntarily joined the VT training group, and twenty-seven seniors voluntarily joined the control group. The VT group received VT training for three months, while the control group received no training. The bone strength of the distal radius was assessed using an ultrasound bone sonometer. Muscular strength in the limbs was evaluated using a Jamar handgrip dynamometer and the five times sit-to-stand test. Shoulder joint mobility was examined using a goniometer. Balance performance and self-efficacy were evaluated using the Berg Balance Scale and the Chinese version of the Activities-specific Balance Confidence Scale, respectively. [Results] The results revealed a nonsignificant group-by-time interaction effect, group effect, and time effect for all outcome variables. However, general trends of maintenance or improvement in all outcome parameters were observed to a greater extent in the VT group than in the control group. [Conclusion] VT training might be a potential fall-prevention exercise that can be used to maintain general physique, balance, and confidence in the elderly population. A further randomized controlled trial is needed to confirm this postulation.

  5. Full k-space visualization of photoelectron diffraction

    International Nuclear Information System (INIS)

    Denlinger, J.D.; Rotenberg, E.; Kevan, S.D.; Tonner, B.P.

    1997-01-01

    The development of photoelectron holography has promoted the need for larger photoelectron diffraction data sets in order to improve the quality of real-space reconstructed images (by suppressing transformational artifacts and distortions). The two main experimental and theoretical approaches to holography, the transform of angular distribution patterns for a coarse selection of energies or the transform of energy-scanned profiles for several directions, represent two limits to k-space sampling. The high brightness of third-generation soft x-ray synchrotron sources provides the opportunity to rapidly measure large high-density x-ray photoelectron diffraction (XPD) data sets with approximately uniform k-space sampling. In this abstract, the authors present such a photoelectron data set acquired for Cu 3p emission from Cu(001). Cu(001) is one of the most well-studied systems for understanding photoelectron diffraction structure and for testing photoelectron holography methods. Cu(001) was chosen for this study in part due to the relatively inert and unreconstructed clean surface, and it served to calibrate and fine-tune the operation of a new synchrotron beamline, electron spectrometer and sample goniometer. In addition to Cu, similar open-quotes volumeclose quotes XPD data sets have been acquired for bulk and surface core-level emission from W(110), from reconstructed Si(100) and Si(111) surfaces, and from the adsorbate system of c(2x2) Mn/Ni(100)

  6. Low angle X-ray scattering in biological tissues

    International Nuclear Information System (INIS)

    Lemos, Carla; Braz, Delson; Pinto, Nivia G.V.; Lima, Joao C.; Castro, Carlos R.F.; Filgueiras, R.A.; Mendonca, Leonardo; Lopes, Ricardo T.; Barroso, Regina C.

    2007-01-01

    Low-angle x-ray scatter (LAXS) for tissue characterization is based on the differences which result from the interference of photons coherently scattered from molecules of each sample. Biological samples (bone, blood and blood components) have been studied in recent years in our laboratory using powder diffractometer. The scattering information was obtained using a Shimadzu DRX 6000 diffractometer at the Nuclear Instrumentation Laboratory, Rio de Janeiro, Brazil. Unpolarized monoenergetic Kα radiation from Cu provided 8.04 keV photons. The measurements were made in reflection mode (θ-2θ geometry), with the sample stationary on a goniometer which rotates the sample and detector about an axis lying in the plane of the top of the sample holder. LAXS profiles from whole blood, plasma and formed elements were measured to investigate the nature of scattering from such lyophilized samples. The statistical analysis shows that the variation found for the characterization parameters is significant for whole blood considering the age. Gender was positively associated with the variation of the second peak position for the profiles obtained for formed elements. The correlation of the measured relative coherent intensity with the mineral content in the bone samples was investigated. These results suggest that the measurement of bone mineral content within trabecular bone can be performed by using quantitative coherent scattering information. (author)

  7. [Modeling polarimetric BRDF of leaves surfaces].

    Science.gov (United States)

    Xie, Dong-Hui; Wang, Pei-Juan; Zhu, Qi-Jiang; Zhou, Hong-Min

    2010-12-01

    The purpose of the present paper is to model a physical polarimetric bidirectional reflectance distribution function (pBRDF), which can character not only the non-Lambertian but also the polarized features in order that the pBRDF can be applied to analyze the relationship between the degree of polarization and the physiological and biochemical parameters of leaves quantitatively later. Firstly, the bidirectional polarized reflectance distributions from several leaves surfaces were measured by the polarized goniometer developed by Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences. The samples of leaves include two pieces of zea mays L. leaves (young leaf and mature leaf) and a piece of E. palcherrima wild leaf. Non-Lambertian characteristics of directional reflectance from the surfaces of these three leaves are obvious. A Cook-Torrance model was modified by coupling the polarized Fresnel equations to simulate the bidirectional polarized reflectance properties of leaves surfaces. The three parameters in the modified pBRDF model, such as diffuse reflectivity, refractive index and roughness of leaf surface were inversed with genetic algorithm (GA). It was found that the pBRDF model can fit with the measured data well. In addition, these parameters in the model are related with both the physiological and biochemical properties and the polarized characteristics of leaves, therefore it is possible to build the relationships between them later.

  8. UAV BASED BRDF-MEASUREMENTS OF AGRICULTURAL SURFACES WITH PFIFFIKUS

    Directory of Open Access Journals (Sweden)

    G. J. Grenzdörffer

    2012-09-01

    Full Text Available BRDF is a common problem in remote sensing and also in oblique photogrammetry. Common approaches of BRDF-measurement with a field goniometer are costly and rather cumbersome. UAVs may offer an interesting alternative by using a special flight pattern of oblique and converging images. The main part of this paper is the description of a photogrammetric workflow in order to determine the anisotropic reflection properties of a given surface. Due to the relatively low flying heights standard procedures from close range photogrammetry were adopted for outdoor usage. The photogrammetric processing delivered automatic and highly accurate orientation information with the aid of coded targets. The interior orientation of the consumer grade camera is more or less stable. The radiometrically corrected oblique images are converted into ortho photos. The azimuth and elevation angle of every point may then be computed. The calculated anisotropy of a winter wheat plot is shown. A system four diagonally-looking cameras (Four Vision and an additional nadir looking camera is under development. The multi camera system especially designed for a Micro- UAV with a payload of min 1 kg. The system is composed of five industrial digital frame cameras (1.3 Mpix CCD-chips, 15 fp/s with fixed lenses. Also special problems with the construction of a light weight housing of the multi camera solution are covered in the paper.

  9. High-resolution x-ray spectroscopy of coherent bremsstrahlung fine structure

    International Nuclear Information System (INIS)

    Lund, M.W.

    1989-01-01

    The aim of this research was to provide experimental evidence for fine structure due to umklapp by distinct reciprocal lattice vectors in coherent bremsstrahlung spectra. The spontaneous emission of photons by relativistic electrons transversing thin crystals is made possible by recoil of the crystal, which absorbs momentum in multiples of ℎG where G is a reciprocal lattice vector. Previous work in the MeV-GeV beam energy range used detectors whose energy resolution was greater than 10%. By fitting a Johann wavelength dispersive spectrometer to a transmission electron microscope the author obtained coherent bremsstrahlung spectra of very high quality with energy resolution of 1%. Important to this result were also the fine angular collimation, small energy width of the electron beam in the microscope, and the accurate control of crystal orientation possible in a modern goniometer stage. The theory of the design of bent crystal x-ray spectrometers is extended to include effects of defocus and aberrations. The theory for diffraction from a stationary three dimensional grating due to a dipole radiator moving at relativistic speeds is derived as well as several other broadening mechanisms stemming from experimental variables. This dissertation provides the first experimental observations and corresponding theoretical background for the fine structure of coherent bremsstrahlung due to umklapp by different G-vectors in the same reciprocal lattice plane

  10. Surface properties and color stability of an acrylic resin combined with an antimicrobial polymer

    Directory of Open Access Journals (Sweden)

    Ana Carolina Pero

    Full Text Available INTRODUCTION: The occurrence of stomatitis is common since the surface characteristics of the dentures may act as reservoirs for microorganisms and have the potential to support biofilm formation. PURPOSE: To assess the surface properties (wettability/roughness and color stability of an acrylic resin combined with the antimicrobial polymer poly (2-tert-butylaminoethyl methacrylate (PTBAEMA. MATERIAL AND METHOD: Thirty disc-shaped specimens of an acrylic resin (Lucitone 550 were divided into three groups: 0% (control; 5% and 10% PTBAEMA. Surface roughness values (Ra were measured using a profilometer and wettability was determined through contact angle measurements using a goniometer and deionized water as a test liquid. Color data were measured with a spectrophotometer. Kruskal-Wallis and Dunn's test were used to compare roughness values. Wettability data were analyzed using ANOVA and Tukey's test. Color data were compared using the Student's t-test and ∆E values were classified according to the National Bureau of Standards (NBS. All statistical analyses were performed considering α=.05. RESULT: Significant differences (p<.05 were detected among the groups for roughness, wettability and color stability. According to the NBS, the color changes obtained in the 5% and 10% PTBAEMA groups were "appreciable" and "much appreciable", respectively. CONCLUSION: It could be concluded that PTBAEMA incorporation in an acrylic resin increased the roughness and wettability of surfaces and produced color changes with clinical relevance.

  11. EFFECTS OF KINESIOTAPING ALONG WITH QUADRICEPS STRENGTHENING EXERCISES ON PAIN, JOINT RANGE OF MOTION AND FUNCTIONAL ACTIVITIES OF KNEE IN SUBJECTS WITH PATELLOFEMORAL OSTEOARTHRITIS

    Directory of Open Access Journals (Sweden)

    M. Harshitha

    2014-08-01

    Full Text Available Background: Patello femoral Osteoarthritis is the most common degenerative disease in older age group, causing pain, physical disability, and decreased quality of life.As many treatment options available, kinesiotaping is an efficacious treatment for management of pain & disability in patellofemoral joint osteoarthritis. Previous studies have shown that kinesiotaping as well as quadriceps strengthening significantly yields functional benefits. But there is lack of evidence revealing combined effectiveness & effects of kinesiotaping along with quadriceps strengthening in subjects with patellofemoral joint osteoarthritis. Methods: 30 subjects with symptoms of patellofemoral osteoarthritis fulfilled the inclusion criteria were randomly assigned into 2 groups of 15 in each group. Taping along with quadriceps strengthening program is compared to the quadriceps strengthening program alone. Pain were measured by Visual Analogue Scale (VAS, knee ROM were measured by Goniometer, Functional status were measured by Western Ontario McMaster Universities index (WOMAC, score. Measurements were taken pre & post intervention. Results: The results indicated that kinesiotaping along with quadriceps strengthening exercises showed there was statistically significant improvement in pain (<0.05, knee ROM (<0.05 and functional activities (<0.05 after 6 weeks compared to quadriceps strengthening alone. Conclusion: Subjects with kinesiotaping along with quadriceps strengthening showed significant improvement in reducing pain, in improving ROM & functional activities at the end of 6th week treatment when compared to subjects with patellofemoral osteoarthritis underwent quadriceps strengthening exercises alone.

  12. Use of an X-ray imaging plate for stress analysis

    International Nuclear Information System (INIS)

    Schubert, A.; Kaempfe, B.; Ermrich, M.; Auerswald, E.; Traenkner, K.

    1994-01-01

    The X-ray diffraction method for stress measurements has been successfully carried out for many years [1]. The basis for the determination of residual and load stresses is the Debye-Scherrer-method and Bragg's law. The Bragg angles of one or several reflections are measured with high precision in the back reflection region. The results permit the determination of changes in interplanar spacings of polycrystalline materials. Conventional stress analysis is based on two commonly used techniques, the so-called ''sin 2 ψ''- and ''φ''-methods, which require measurements at different tilting and rotating positions of the sample by the help of a Ψ- or Ω-goniometer [1, 2, 3]. In these cases the interplanar spacings and consequently the shift of the peak can be determined with conventional counters or position sensitive detectors. From the whole diffraction cone only a small part of lattice planes {hkl} with a special orientation (ψ, φ) is analysed. The use of a two-dimensional detector like an imaging plate [4] offers the possibility to get diffraction patterns in one measurement from lattice planes {hkl} having one ψ and all φ orientations (non-tilted case) or different ψ and different φ orientations (tilted case). Thus the number of measurements for the calculation of the stress components can be significantly reduced. Further it is possible to investigate both textured materials and coarse-grained samples. (orig.)

  13. An MRI-based technique for assessment of lower extremity deformities - reproducibility, accuracy, and clinical application

    International Nuclear Information System (INIS)

    Hinterwimmer, Stefan; Graichen, Heiko; Vogl, Thomas J.; Abolmaali, Nasreddin

    2008-01-01

    The hypothesis of this study was that length, torsion, and axis of a leg phantom can be measured accurately and reproducibly by magnetic resonance imaging (MRI) and that this can be applied to patients with leg deformities. Two phantoms and 30 patients (genu varum, n=15; genu valgum, n=15) were investigated using an optimized MRI technique. Reference measurements were performed with a micrometer screw and a goniometer. Patient leg length and axis were compared with long radiographs in bipedal stance. Intra- and interobserver reproducibility and accuracy were calculated using the mean absolute difference (MAD) and the 95% confidence interval. In patients, comparisons were done using a paired Student's t-test. MAD, intraobserver MAD, and interobserver MAD were 0.03, 0.03, 0.04 mm (length); 0.98, 1.2, 0.98 (torsion); and 0.18, 0.23, 0.22 (axis), respectively. In patients, leg length was underestimated by MRI (-2.4 ± 0.7%; 1.9±0.7 cm; P 0.05), while it was significantly underestimated in valgus knees (-3.6 ± 2.8 ; P<0.05). The phantom study revealed that leg length, torsion, and axis can be measured accurately and reproducibly by MRI. Although underestimation of leg length and HKA in valgus knees occurred, this optimized MRI technique can be applied to patients with leg deformities. (orig.)

  14. Extension and flexion in the upper cervical spine in neck pain patients.

    Science.gov (United States)

    Ernst, Markus J; Crawford, Rebecca J; Schelldorfer, Sarah; Rausch-Osthoff, Anne-Kathrin; Barbero, Marco; Kool, Jan; Bauer, Christoph M

    2015-08-01

    Neck pain is a common problem in the general population with high risk of ongoing complaints or relapses. Range of motion (ROM) assessment is scientifically established in the clinical process of diagnosis, prognosis and outcome evaluation in neck pain. Anatomically, the cervical spine (CS) has been considered in two regions, the upper and lower CS. Disorders like cervicogenic headache have been clinically associated with dysfunctions of the upper CS (UCS), yet ROM tests and measurements are typically conducted on the whole CS. A cross-sectional study assessing 19 subjects with non-specific neck pain was undertaken to examine UCS extension-flexion ROM in relation to self-reported disability and pain (via the Neck Disability Index (NDI)). Two measurement devices (goniometer and electromagnetic tracking) were employed and compared. Correlations between ROM and the NDI were stronger for the UCS compared to the CS, with the strongest correlation between UCS flexion and the NDI-headache (r = -0.62). Correlations between UCS and CS ROM were fair to moderate, with the strongest correlation between UCS flexion and CS extension ROM (r = -0.49). UCS flexion restriction is related to headache frequency and intensity. Consistency and agreement between both measurement systems and for all tests was high. The results demonstrate that separate UCS ROM assessments for extension and flexion are useful in patients with neck pain. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Effect of manual therapy versus proprioceptive neuromuscular facilitation in dynamic balance, mobility and flexibility in field hockey players. A randomized controlled trial.

    Science.gov (United States)

    Espí-López, Gemma V; López-Martínez, Susana; Inglés, Marta; Serra-Añó, Pilar; Aguilar-Rodríguez, Marta

    2018-04-22

    To compare the effectiveness of a specific Manual Therapy (MT) protocol applied to field hockey players (FHP), versus a Proprioceptive Neuromuscular Facilitation (PNF) protocol, in the improvement of dynamic balance, active range of movement and lumbar flexibility one-week and four-weeks after the treatment. Randomized controlled trial. Participants were assigned to 2 groups: MT and PNF. 30 min' sessions were performed once a week for three weeks. Three evaluations were performed: basal, one-week and four-weeks post-treatment. University of Valencia (Spain). 22 in MT group and 20 in PNF group. Dynamic Balance, measured with Star Excursion Balance Test; Active Range of Motion (ROM), using a manual goniometer and Lumbar Flexibility, assessed with Fingertip-to-floor test. Both groups significantly improved in lateral and medial dynamic balance one-week post-treatment (p < 0.05); but the improvement in the MT group lasted until the fourth-week after treatment in both reaches (lateral and medial) (p < 0.05). MT group also obtained significant improvements in dorsal flexion of the ankle in the fourth-week post-treatment (p < 0.05) and in lumbar flexibility one-week post-treatment (p < 0.05). MT and PNF improve dynamic balance one-week post-treatment; however, the improvement obtained through MT is maintained four-weeks later. Only MT improves dorsal flexion of the ankle four-weeks post-treatment and lumbar flexibility one-week post-treatment. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. EFFECTS OF CORE STABILIZATION PROGRAM AND CONVENTIONAL EXERCISES IN THE MANAGEMENT OF PATIENTS WITH CHRONIC MECHANICAL LOW BACK PAIN

    Directory of Open Access Journals (Sweden)

    Suresh Babu Reddy .A

    2015-04-01

    Full Text Available Background: Conventional back care exercises are advocated to treat the pain and to strengthen the involved muscles. There will be possibility of the pain getting recurred due to disproportionate balance and stability in the muscles. The core stabilization is major trend in rehabilitation, it aims at improving stability during functional activities, balance, flexibility, strength training and effectively manage the pain as well. Objective: To find the efficacy of the concept of core stabilization when compared to conventional back care exercises in patients with chronic mechanical low back pain. Methods: Forty patients with chronic Mechanical Low back pain were selected through purposive sampling and were randomly assigned into control group who received conventional back exercises and SWD (n=20, experimental group who received core stabilization and SWD (n=20. Both the groups received SWD, along with conventional back exercises for one group and core stabilization for the other group three days a week for 6 weeks. The treatment outcome was assessed using visual analogue scale, Rolland Morris Disability Questionnaire and Lumbar range of motion using goniometer. Results: After a 6 weeks training period the core stabilization group scored significantly higher than the conventional group for VAS (p=0.05 RMDQ (p=0.05 whereas ROM improved higher in conventional group (p=0.05. Conclusion: After the treatment sessions Core stabilization group registered a significant improvement when compared to conventional back care exercises in improving function and in relieving pain.

  17. The Effect of Various Standing Positions in Muscles Activity between Healthy Young Men and those with Genu Varum

    Directory of Open Access Journals (Sweden)

    Persian Abstract Amir Hossein Barati

    2015-09-01

    Full Text Available Objective: Genu varum is considered a risk factor for knee osteoarthritis. Being aware of the changes in muscles activity in various standing positions among genu varum patients, can provide insight for preventing osteoarthritis in this population. This study is undertaken to compare muscles activity in various standing positions between young healthy and genu varum male individuals. Methods: 80 healthy male university students, 40 normal and 40 subjects with genu varum deformity, participated in this study. Deformity of genu varum was assessed with caliper and Goniometer. Each subject stood in five different positions and muscles activity was recorded with EMG device. For data analysis, Matlab and SPSS software were employed and Mixed variance analysis test (Mixed ANOVA was run to compare the dependent variables at a significance level of P ≤ 0.05. Results: Significant differences were observed between the two groups for muscles activity of the tensor fasia latae (at single leg with closed eye position, tertius fibulae and gluteus medius muscles (at single leg with closed eye and upward head postions( p≤0.05 while no significant differences were observed in other muscles. Conclusion: According to the obtained results, it can be suggested that frontal knee angle may affect muscles activity. Perhaps one of the reasons for higher injury risk and knee osteoarthritis in genu varum population is the increase in muscles activity. Therefor, It is proposed that focusing on corrective exercises can reduce these risks.

  18. A COMPARATIVE STUDY ON EFFECTIVENESS OF STATIC STRETCH AND HOLD RELAX TECHNIQUES OVER HAMSTRING FLEXIBILITY

    Directory of Open Access Journals (Sweden)

    N. Vamsidhar

    2014-12-01

    Full Text Available Background: Flexibility is important in prevention of injury, muscular and postural imbalance more over the Hamstring flexibility has a lion share in sports performances and preventing DOMS. Stretching procedures increases the ROM by embarking on biomechanics and Neurologic and molecular mechanics. Hamstrings, the two joint muscle plays a crucial role in two joints integrity and also spine as they are in closed kinematic chain. The hamstring muscles represent the primary flexors of Knee. Hamstrings tightness results in Limits Knee extension when hip is flexed, Posterior Pelvic tilt, and flatten the lumbar spine. Methods: The subjects selected randomly and divided into two groups (Experimental group and control group.30 samples in One group applied with Static Stretch once a day for 3 repetitions 5 days a week for six weeks and 30 samples in other group applied with Hold relax technique once a day for 4 repetitions 5 days a week for six weeks. The knee joint range of motion was measured at the end of every week with Universal goniometer. Results: By comparing the means of Group – I, given Static Stretch and Group – II, given Hold relax Technique for six weeks implied that there is improvement of flexibility in Group – II and the ‘P’ value < 0.01 shows the difference is highly significant. Conclusion: This study concludes that the hold relax Technique method has proved to be better technique then the static stretch for improving hamstring flexibility.

  19. Study of the number of neutrons produced by fission of 239Pu

    International Nuclear Information System (INIS)

    Jacob, M.

    1958-01-01

    Study of the number of neutrons produced by fission of 239 Pu. The counting by coincidence of fissions and neutrons produced by these fissions allows the study of the variation of the mean number of neutrons emitted by ν fission. In the first chapter, it studied the variation of the mean number of neutrons emitted by 239 Pu fission with the energy of the incident neutron. A description of the experiment is given: a spectrometer with a crystal of sodium chloride or beryllium (mounted on a goniometer) is used, a fission chamber containing 10 mg of 239 Pu and the neutron detection system constituted of BF 3 counters which are enriched in 10 B. In the second part, the counting by coincidence of fissions and neutrons produced by the same fission and received by two different groups of counters allow the determination of a relationship between the root mean square and the average of neutron number produced by fission. The variation of the mean number of neutrons emitted by fission of 239 Pu is studied when we change from a thermal spectra of neutrons to a fission spectra of incident neutrons. Finally, when separating in two different part the fission chamber, it is possible to measure the mean number of neutrons emitted from fission of two different sources. It compared the mean number of neutrons emitted by fission of 239 Pu and 233 U. (M.P.)

  20. Study of the number of neutrons produced by fission of {sup 239}Pu; Etude du nombre de neutrons produits par la fission de {sup 239}Pu

    Energy Technology Data Exchange (ETDEWEB)

    Jacob, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    Study of the number of neutrons produced by fission of {sup 239}Pu. The counting by coincidence of fissions and neutrons produced by these fissions allows the study of the variation of the mean number of neutrons emitted by {nu} fission. In the first chapter, it studied the variation of the mean number of neutrons emitted by {sup 239}Pu fission with the energy of the incident neutron. A description of the experiment is given: a spectrometer with a crystal of sodium chloride or beryllium (mounted on a goniometer) is used, a fission chamber containing 10 mg of {sup 239}Pu and the neutron detection system constituted of BF{sub 3} counters which are enriched in {sup 10}B. In the second part, the counting by coincidence of fissions and neutrons produced by the same fission and received by two different groups of counters allow the determination of a relationship between the root mean square and the average of neutron number produced by fission. The variation of the mean number of neutrons emitted by fission of {sup 239}Pu is studied when we change from a thermal spectra of neutrons to a fission spectra of incident neutrons. Finally, when separating in two different part the fission chamber, it is possible to measure the mean number of neutrons emitted from fission of two different sources. It compared the mean number of neutrons emitted by fission of {sup 239}Pu and {sup 233}U. (M.P.)

  1. A new approach in performing microdiffraction analysis

    International Nuclear Information System (INIS)

    Winter, D.J.; Squires, B.A.

    1995-01-01

    Microdiffraction is defined as the x-ray diffraction analysis performed on small samples or MD areas of large samples. Since smallness is a relative term, microdiffraction is considered the technique of choice when samples are too small for the optics and precision of conventional instrumentation. The limit on the size of the sample is dependent upon the accuracy of the instrumentation, which is measured by such variables as the diameter of the incident beam and the sphere of confusion of the goniometer (accuracy of the circle centers). If the sample area of interest is part of a multiphase material, it is necessary for the diameter of the incident x-ray beam to be smaller than the sample area in order to assure that the diffraction pattern produced is from the sample area of interest only. Today, microdiffraction is being performed on samples as small as a few microns in diameter. Common applications for microdiffraction include composite materials such as wafers and pads used in the semiconductor industry, inclusions on laser disks and forensic studies. The analysis is often complicated by the fact that the sample areas can be a few grains or even a single crystal. Conventional powder diffractometers are very well suited for analyzing large volumes of polycrystalline material, however, they require much longer counting times when the sample volume is very small. Ideally, what is needed is the optics of a single crystal diffractometer with the performance of a conventional powder diffractometer. 6 figs

  2. Serial casting versus stretching technique to treat knee flexion contracture in children with spina bifida: a comparative study.

    Science.gov (United States)

    Al-Oraibi, S; Tariah, Hashem Abu; Alanazi, Abdullah

    2013-01-01

    Severe knee contractures that develop soon after muscle imbalance may not improve with stretching exercises and splinting. An alternative treatment is serial casting, which has been used to promote increased range of motion. The purpose of this study was to compare the effectiveness of using serial casting and passive stretching approaches to treat knee flexion contracture in children with spina bifida. In a pre/post randomized controlled study, ten participants were included in the serial casting group, while eight participants were included in the passive stretching intervention group. The degree of knee extension was measured at baseline, immediately after intervention, and at a one-year follow-up using a standard goniometer. Both groups showed significant improvements in the degree of flexion contracture at the post-treatment evaluation and the follow-up evaluation. The serial casting group showed significant improvements in knee flexion contracture at the post-treatment evaluation, t (9)=13.4, p casting group compared with passive stretching group in relation to the degree of flexion contracture were found at the immediate post-treatment evaluation, F(1, 15)=246, p=0.0001, and the one-year follow-up evaluation, F (1, 15)=51.5, p=0.0001. The outcomes of this study provide the first evidence that serial casting may be a useful intervention in treating knee flexion contracture in children with spina bifida. However, further investigations into serial casting, as well as investigations into the use of serial casting with other interventions, are warranted.

  3. Comparison of the effect of three different irrigants on the contact angle of an epoxy resin sealer with intraradicular dentin

    Directory of Open Access Journals (Sweden)

    Mamta Kaushik

    2015-01-01

    Materials and Methods: Seventy human mandibularfirst premolars were used and 140 longitudinal dentin slices were obtained from them. Each sample was irrigated with of 3% sodium hypochlorite (NaOCl, simulating the irrigation used during the chemomechanical preparation and then washed with 10ml of distilled water (DW. The samples were then divided into seven groups of 20 samples each. Group 1:NaOCl + DW, Group 2: QMix + DW, Group 3: 0.1% octenidine hydrochloride + DW, Group 4:Ethylenediaminetetraacetic acid (EDTA + DW + NaOCl + DW, Group 5: EDTA + DW + QMix + DW, Group 6: EDTA + DW + 0.1% Octenidine Hydrochloride + DW, and Group 7(control: DW. The contact angle between AH Plus and the samples was measured using Rame Hart Goniometer followed by statistical analysis of data. Results: Values of contact angle was least when samples were treated with QMix followed by treatment with 0.1% Octenidine Hydrochloride followed by 3% NaOCl. Removal of smear layer reduced contact angles in all cases except when samples were treated with 3% NaOCl. Results were statistically significant when 3% NaOCl was compared to 0.1% Octenidine Hydrochloride and QMix (P = 0.034. Statistically significant difference was seen before and after removal of smear layer for 3% NaOCl and 0.1% Octenidine Hydrochloride. (P = 0.003. Conclusion: Qmix is the irrigant of choice, but 0.1% octenidine hydrochloride may be recommended as a useful irrigant after further research.

  4. Wettability changes in polyether impression materials subjected to immersion disinfection.

    Science.gov (United States)

    Shetty, Shweta; Kamat, Giridhar; Shetty, Rajesh

    2013-07-01

    Disinfection of impression materials prevents cross-contamination; however, the disinfectants may alter the wettability property. The purpose of this investigation was to evaluate the wettability changes of polyether impression material after immersing in four different chemical disinfectant solutions for a period of 10 min and 30 min, respectively. A total of 45 samples of polyether dental impression material (Impregum soft, 3MESPE, St. Paul, MN, USA) were randomly divided into nine groups with five specimens each. Each specimen was disc shaped, flat of 32 mm diameter and 3 mm thickness. The samples were immersed in four disinfectant solutions: 2% Glutaraldehyde, 5% sodium hypochlorite, 0.05% iodophor, and 5.25% phenol for 10 min and 30 min, respectively. The control was without disinfection. Wettability of the samples was assessed by measuring the contact angle by using the Telescopic Goniometer. Data were subjected to analysis of variance (Fisher's test) and Tukey's post hoc test for multiple comparisons at 5% level of significance. The contact angle of 20.21° ± 0.22° were recorded in the control samples. After 10 min, the samples that were immersed in 5% sodium hypochlorite and 5.25% phenol showed significant statistical increase in the contact angle as compared to the control (P polyether material. Within the limitations of the study, 2% glutaraldehyde proved safe for 10 min of immersion disinfection while 0.05% iodophor holds promise as an effective disinfectant without affecting the wettability of the material.

  5. 3S-R10 automated RBS system

    International Nuclear Information System (INIS)

    Norton, G.A.; Schroeder, J.B.; Klody, G.M.; Strathman, M.D.

    1989-01-01

    The NEC 3S-R10 automated RBS spectrometer system includes the features required for routine application of Rutherford backscattering (RBS) and related techniques for materials analysis in both research and industrial settings. The NEC Model 3SDH Pelletron accelerator system provides stable, monoenergetic beams of helium ions up to 3.3 MeV and protons to 2.2 MeV and has heavy ion capability. The analytical end station is the fully computerized Charles Evans and Associates Model RBS-400. Automated features include sample positioning (precision 4-axis goniometer), channeling alignment, polar plot generation, and data acquisition and reduction. Computer automation of accelerator and chamber functions includes storage and recall of operating parameters. Unattended data acquisition, e.g., overnight or over a weekend, is possible for up to 100 samples per batch for random orientation, rotating random or channeling analyses at any sample location. Single samples may be up to 50 cm in diameter. A laser for sample alignment and a TV for video monitoring are included. Simultaneous detection (up to 4 detectors) at normal and grazing angles, external control of grazing angle detector position, and transmission scattering capabiltiy enhance system flexibility. The system is also compatible with PIXE, NRA, and hydrogen forward-backscattering analyses. Data reduction is part of the computer system, which features displays (several formats) and manipulation of up to five spectra at one time using constant multipliers or point by point operations between spectra. (orig.)

  6. An on-ice measurement approach to analyse the biomechanics of ice hockey skating.

    Directory of Open Access Journals (Sweden)

    Erica Buckeridge

    Full Text Available Skating is a fundamental movement in ice hockey; however little research has been conducted within the field of hockey skating biomechanics due to the difficulties of on-ice data collection. In this study a novel on-ice measurement approach was tested for reliability, and subsequently implemented to investigate the forward skating technique, as well as technique differences across skill levels. Nine high caliber (High and nine low caliber (Low hockey players performed 30 m forward skating trials. A 3D accelerometer was mounted to the right skate for the purpose of stride detection, with the 2nd and 6th strides defined as acceleration and steady-state, respectively. The activity of five lower extremity muscles was recorded using surface electromyography. Biaxial electro-goniometers were used to quantify hip and knee angles, and in-skate plantar force was measured using instrumented insoles. Reliability was assessed with the coefficient of multiple correlation, which demonstrated moderate (r>0.65 to excellent (r>0.95 scores across selected measured variables. Greater plantar-flexor muscle activity and hip extension were evident during acceleration strides, while steady state strides exhibited greater knee extensor activity and hip abduction range of motion (p<0.05. High caliber exhibited greater hip range of motion and forefoot force application (p<0.05. The successful implementation of this on-ice mobile measurement approach offers potential for athlete monitoring, biofeedback and training advice.

  7. Effects of special composite stretching on the swing of amateur golf players.

    Science.gov (United States)

    Lee, Joong-Chul; Lee, Sung-Wan; Yeo, Yun-Ghi; Park, Gi Duck

    2015-04-01

    [Purpose] The study investigated stretching for safer a golf swing compared to present stretching methods for proper swings in order to examine the effects of stretching exercises on golf swings. [Subjects] The subjects were 20 amateur golf club members who were divided into two groups: an experimental group which performed stretching, and a control group which did not. The subjects had no bone deformity, muscle weakness, muscle soreness, or neurological problems. [Methods] A swing analyzer and a ROM measuring instrument were used as the measuring tools. The swing analyzer was a GS400-golf hit ball analyzer (Korea) and the ROM measuring instrument was a goniometer (Korea). [Results] The experimental group showed a statistically significant improvement in driving distance. After the special stretching training for golf, a statistically significant difference in hit-ball direction deviation after swings were found between the groups. The experimental group showed statistically significant decreases in hit ball direction deviation. After the special stretching training for golf, statistically significant differences in hit-ball speed were found between the groups. The experimental group showed significant increases in hit-ball speed. [Conclusion] To examine the effects of a special stretching program for golf on golf swing-related factors, 20 male amateur golf club members performed a 12-week stretching training program. After the golf stretching training, statistically significant differences were found between the groups in hit-ball driving distance, direction deviation, deflection distance, and speed.

  8. Acute effect of different time periods of passive static stretching on the hamstring flexibility.

    Science.gov (United States)

    Cini, Anelize; de Vasconcelos, Gabriela Souza; Lima, Claudia Silveira

    2017-01-01

    Several factors are associated with the presence of chronic low back pain; one of them is the flexibility of the hamstring muscles that influences the posture of the pelvic spine. Investigate the influence of two different time periods of passive static stretching on the flexibility of the hamstring. Forty-six physiotherapy students were divided into two groups performing stretching exercises: 30 s and 60 s duration. The collections consisted of: (1) pre-test: evaluation of the flexibility of the hip and knee, using a manual goniometer by means of the following tests: Straight Leg Raise Test (SLR), Passive Hip Flexion Test (PHFT) and Modified Knee Extension Test (MKET), (2) intervention: stretching with different runtimes, (3) post-test: reappraisal of flexibility, conducted immediately after the intervention. Significant difference was observed intra groups, group that did stretching exercises lasting 30 seconds (G30) (SLR p = 0.000. PHFT p = 0.003 and MKET p = 0.000) and group that did stretching exercises lasting 60 seconds (G60) (SLR p = 0.000. PHFT p = 0.001 and MKET p = 0.002). Comparing the groups, no significant difference was found (SLR p = 0.307; PHFT p = 0.904; MKET p = 0.132). Thus it can be inferred that 30 seconds are sufficient for increased flexibility of young women. Therefore the time-treatment sessions can be optimized. Only the acute effect of stretching was observed; further investigation of the long-term effect is required.

  9. Light scattering by rough surfaces for increase of absorption of low band gap light in solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Kloppstech, Konstantin; Knabe, Sebastian; Bauer, Gottfried H. [Institute of Physics, Carl von Ossietzky University Oldenburg (Germany)

    2011-07-01

    Scattering of low band gap light for the increase of the absorption of low band gap photons is commonly formulated in phenomenological magnitudes such as haze factors resulting from experiments at particular scattering media. We have formulated analytically and described by numerical simulations the scattering of light by the interaction of photons with rough surfaces based on wave numbers of photons k{sub {lambda}} and wave numbers of the topological surface contour k{sub s} that has been derived in 2 dimensions via AFM analyses of the contour function h(x,y) of the scattering medium, e.g. a glassy diffusor. We have distinguished two regimes: i) k{sub {lambda}}goniometer - are compared with the simulation of numerically generated far field results in dependence of distance r from the scattering medium and scattering angle {beta}. In particular for the wave optical approach we find a ''scattering function'' that contains the contour function h(x,y) however that substantially departs from its puristic Fourier Transform.

  10. Differences in active range of motion measurements in the upper extremity of patients with writer's cramp compared with healthy controls.

    Science.gov (United States)

    Srivanitchapoom, Prachaya; Shamim, Ejaz A; Diomi, Pierre; Hattori, Takaaki; Pandey, Sanjay; Vorbach, Sherry; Park, Jung E; Wu, Tianxia; Auh, Sungyoung; Hallett, Mark

    Exploratory case-control study. Writer's cramp (WC) is a type of focal hand dystonia. The central nervous system plays a role in its pathophysiology, but abnormalities in the affected musculoskeletal components may also be relevant. We compared the active range of motion (ROM) in patients with WC and healthy volunteers (HVs) and correlated the findings with disease duration and severity. Affected limb joints were measured with goniometers. Patients were assessed at least 3 months after their last botulinum toxin (botulinum neurotoxin) injection, and strength was clinically normal. t tests were used to compare the ROMs of WC with matched HVs. The Spearman correlation coefficient assessed the relationship of active ROMs to the disease duration and handwriting subscore of the Dystonia Disability Scale. ROMs of D1 metacarpophalangeal (MCP) joint extension as well as D2 and D5 MCP flexion were significantly smaller in WC, and distal interphalangeal joint extension in D3 and D5 was significantly greater compared with HVs. There were negative correlations between D2 MCP flexion and disease duration and with Dystonia Disability Scale. Abnormalities in ROMs in WC were found. Severity and disease duration correlated with reduced D2 MCP flexion. This may be related to intrinsic biomechanical abnormalities, co-contraction of muscles, or a combination of subclinical weakness and atrophy from repeated botulinum neurotoxin injections. Hand biomechanical properties should not be ignored in the pathophysiology of WC. 2c. Copyright © 2016 Hanley & Belfus. All rights reserved.

  11. Design of a microcomputer-based X-ray diffractometer controller

    International Nuclear Information System (INIS)

    Naval, P.C. Jr.

    1988-01-01

    This work describes the design of an Apple II-based X-ray diffractometer controller capable of acquiring and analyzing X-ray powder diffraction data. The controller's interrupt-drivers hardware includes an on-based scaler for counting X-ray pulses, a closed-loop stepper motor driver for Philips PW 1050 Vertical Goniometer, and circuits for present data collection and safety. ACQUIRE - data acquisition program for the controller coordinates its various devices so that it can perform sample scanning in any of the following modes: continuous, present tome or present count scanning. This program watches over the scanning process and will try to correct any error it detects. Any fault monitored is logged on disk. The collected diffraction data are stored on disk together with its data acquisition parameters and may be transported to another computer. Data analysis is done by ANALYZE a program that operates on the output file generated by ACQUIRE. Its 15 single-keystroke commands permit panning and zooming of the sample's diffractogram, data smoothing, data peak search, peak report generation, and digital plotting. Data smoothing uses a third-degree Savitzky-Golay Convoluting Filter of user defined width. For peak detection, the peak search algorithm examines the diffractograms second derivative for any Gaussian resemblance and checks the peaks' area for statistical significance. The hard copy plot is available from any on-line digital plotted supporting EPSON's Mode D Plotter Commands. (Author). 15 refs. Appendixes p. 85-163

  12. Validation of hand and foot anatomical feature measurements from smartphone images

    Science.gov (United States)

    Amini, Mohammad; Vasefi, Fartash; MacKinnon, Nicholas

    2018-02-01

    A smartphone mobile medical application, previously presented as a tool for individuals with hand arthritis to assess and monitor the progress of their disease, has been modified and expanded to include extraction of anatomical features from the hand (joint/finger width, and angulation) and foot (length, width, big toe angle, and arch height index) from smartphone camera images. Image processing algorithms and automated measurements were validated by performing tests on digital hand models, rigid plastic hand models, and real human hands and feet to determine accuracy and reproducibility compared to conventional measurement tools such as calipers, rulers, and goniometers. The mobile application was able to provide finger joint width measurements with accuracy better than 0.34 (+/-0.25) millimeters. Joint angulation measurement accuracy was better than 0.50 (+/-0.45) degrees. The automatically calculated foot length accuracy was 1.20 (+/-1.27) millimeters and the foot width accuracy was 1.93 (+/-1.92) millimeters. Hallux valgus angle (used in assessing bunions) accuracy was 1.30 (+/-1.29) degrees. Arch height index (AHI) measurements had an accuracy of 0.02 (+/-0.01). Combined with in-app documentation of symptoms, treatment, and lifestyle factors, the anatomical feature measurements can be used by both healthcare professionals and manufacturers. Applications include: diagnosing hand osteoarthritis; providing custom finger splint measurements; providing compression glove measurements for burn and lymphedema patients; determining foot dimensions for custom shoe sizing, insoles, orthotics, or foot splints; and assessing arch height index and bunion treatment effectiveness.

  13. EFFECTIVENESS OF ISCHEMIC COMPRESSION ON TRAPEZIUS MYOFASCIAL TRIGGER POINTS IN NECK PAIN

    Directory of Open Access Journals (Sweden)

    Pragnya Ravichandran

    2016-04-01

    Full Text Available Background: Neck pain is a common disorder prevailing among individuals of different populations. The myofascial pain syndrome is a disorder related to myofascial trigger points. It is defined as a hyperirritable locus in skeletal muscle and that is associated with a hypersensitive palpable nodule in a taut band of muscle. Manual therapy has got a profound role in treating and ischemic compression technique has been researched widely. Thus the study intends to analyse the effectiveness of Manual Therapy (Ischemic Compression on functional outcome in neck pain. Methods: A single blinded randomized control study was conducted for subjects of sample size 30 who met the inclusion criteria and random allocation was made. The baseline parameters as like pain severity using VAS, pain pressure threshold using pressure Algometer, active cervical lateral flexion using 360 degree goniometer and disability using NDI were recorded. Study group received ischemic compression followed by myofascial stretches while the control group received ultrasonic therapy of 1.4watts/cm2. Both received Cryotherapy post session. After 2 weeks the baseline parameters were again recorded for t-test analysis. Result: There was no statistical significance between groups (p≥0.05. But active cervical lateral flexion showed improved mobility in study group and a high statistical significance within groups (p≤0.01 in relation to all parameters. Conclusion: Both ultrasonic therapy and Ischemic compression technique was found to show better improvement in pain pressure threshold and functional outcome in neck pain.

  14. The effectiveness of isometric exercises as compared to general exercises in the management of chronic non-specific neck pain.

    Science.gov (United States)

    Khan, Muhammad; Soomro, Rabail Rani; Ali, Syed Shahzad

    2014-09-01

    To evaluate the effectiveness of isometric exercises as compared to general exercises in chronic non-specific neck pain. For this randomised controlled trial total 68 patients (34 each group) with chronic non-specific neck pain were recruited from Alain Poly Clinic and Institute of Physical Medicine & Rehabilitation Dow University of Health Sciences, Karachi between May, 2012 and August, 2012. Simple randomisation method was used to assign participants into isometric exercise group and general exercise groups. The isometric exercise group performed exercises for neck muscle groups with a rubber band and general exercises group performed active range of movement exercises for all neck movements. Patients in both groups received 3 supervised treatment sessions per week for 12 weeks. Visual Analogue Scale (VAS), North wick Park Neck Pain Questionnaire and goniometer were used to assess pain, disability and neck range of movements at baseline and after 12 weeks. Both interventions showed statistically significant improvements in pain, function and range of movement p = 0.001f or isometric exercise group, p = 0.04 for general exercises group and p = 0.001 for range of movement. However, mean improvements in post intervention VAS score and North wick Park Neck Pain Questionnaire score was better in isometric exercises group as compared to general exercise group. In conclusion, both interventions are effective in the treatment of chronic non-specific neck pain however; isometric exercises are clinically more effective than general exercises.

  15. RAFT-mediated synthesis of cationic poly[(ar-vinylbenzyl)trimethylammonium chloride] brushes for quantitative DNA immobilization

    International Nuclear Information System (INIS)

    Demirci, Serkan; Caykara, Tuncer

    2013-01-01

    The synthesis of cationic poly[(ar-vinylbenzyl)trimethylammonium chloride)] [poly(VBTAC)] brushes was achieved via reversible addition-fragmentation chain transfer (RAFT) polymerization and used for quantitative DNA immobilization. Initially, silicon surfaces were modified with RAFT chain transfer agent by utilizing an amide reaction involving a silicon wafer modified with allylamine and 4-cyanopentanoic acid dithiobenzoate (CPAD). Poly(VBTAC) brushes were then prepared via RAFT-mediated polymerization from the surface immobilized CPAD. Various characterization techniques including ellipsometry, X-ray photoelectron spectroscopy, grazing angle-Fourier transform infrared spectroscopy, atomic force microscopy and contact-angle goniometer were used to characterize the immobilization of CPAD on the silicon wafer and the subsequent polymer formation. The addition of free CPAD was required for the formation of well-defined polymer brushes, which subsequently resulted in the presence of free polymer chains in solution. The free polymer chains were isolated and used to estimate the molecular weights and polydispersity index of chains attached to the surface. Moreover, from atomic force microscopy and ellipsometry measurements, it was also determined that the density of immobilized DNA on the cationic poly(VBTAC) brushes can be quantitatively controlled by adjusting the solution concentration. Highlights: ► The cationic poly(VBTAC) brushes were prepared by RAFT polymerization. ► Grafting density of cationic poly(VBTAC) brushes was as high as 0.76 chains/nm 2 . ► The cationic poly(VBTAC) brushes were used for quantitative DNA immobilization.

  16. Development of a SAXS equipment for the nanomaterials characterization

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Rauni Coelho; Campos, Jose Brant de; Amaral, Jorge Luis Machado, E-mail: rauni.coelho@gmail.com [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil); Lima Junior, Herman Pessoa; Cardoso, Rodrigo Felix [Centro Brasileiro de Pesquisas Fisicas (CBPF), Rio de Janeiro, RJ (Brazil)

    2016-07-01

    Full text: The increase use of nanomaterials requires the creation of techniques and the associated equipment to allow the property evaluation at the nanometer scale. SAXS (Small Angle X-Ray Scattering), technique allows the analysis of nanomaterials and the determination of various parameters such as particle size, density and morphology of nanoparticles [1,2]. The SAXS equipment is a powerful tool in development and research at the nanoscale in order to improve understanding of the different properties of these materials and its comparison with the microscopic properties. But due to its costs, such equipment are extremely scarce in developing countries, because they are marketed with high values. This work aims at the development of collimating optics of a SAXS equipment, based on the geometry of a goniometer in a diffractometer Seifert HZG 4. The xray scattered signal reception is performed using bidimensional X-ray detector developed and manufactured at Laboratorio de Sistemas de Deteccao of Centro Brasileiro de Pesquisas Fisicas, RJ, Brazil (LSD/CBPF). In the present work, it will be presented the X-ray collimation system design and the first results of SAXS operation. Those results show the geometric characteristics of the X-ray beam in the SAXS equipment, received in the bidimensional detector, after traveling the entire optical path. [1] O. Glatter and O. Kratky (edts.), Small-Angle X-ray Scattering (Academic, London, 1982). [2] Heimo Schnablegger and Yashveer Singh. The SAXS Guide. Getting acquainted with the principles. 3.edition. (author)

  17. Investigation of diffractive optical element femtosecond laser machining

    Energy Technology Data Exchange (ETDEWEB)

    Chabrol, Grégoire R., E-mail: g.chabrol@ecam-strasbourg.eu [ECAM Strasbourg-Europe, Espace Européen de l’entreprise, 2, rue de Madrid – 67300 SCHILTIGHEIM, CS. 20013, 67012 Strasbourg CEDEX (France); Laboratoire des Sciences de l’Ingénieur, de l’Informatique et de l’Imagerie (ICube), UDS-CNRS, UMR 7357, 300 bld Sébastien Brant, CS 10413, 67412 Illkirch cedex (France); Ciceron, Adline [ECAM Strasbourg-Europe, Espace Européen de l’entreprise, 2, rue de Madrid – 67300 SCHILTIGHEIM, CS. 20013, 67012 Strasbourg CEDEX (France); Laboratoire des Sciences de l’Ingénieur, de l’Informatique et de l’Imagerie (ICube), UDS-CNRS, UMR 7357, 300 bld Sébastien Brant, CS 10413, 67412 Illkirch cedex (France); Twardowski, Patrice; Pfeiffer, Pierre [Laboratoire des Sciences de l’Ingénieur, de l’Informatique et de l’Imagerie (ICube), UDS-CNRS, UMR 7357, 300 bld Sébastien Brant, CS 10413, 67412 Illkirch cedex (France); Télécom Physique Strasbourg – Pôle API – 300 Bd Sébastien Brant – CS 10413, Illkirch Graffenstaden F 67400 (France); and others

    2016-06-30

    Highlights: • A method for rapid manufacturing of optical diffractive element in BK7 is proposed. • A binary grating in BK7 was successfully machined by femtosecond laser pulses. • Process relying on nonlinear absorption in the dielectric due to photoionization. • The binary grating was analysed by SEM and interferometric microscopy. • Simulations by Fourier modal method supported the measured diffractive efficiency. - Abstract: This paper presents an explorative study on the machining of diffractive optical elements (DOEs) in transparent materials using a femtosecond laser source. A simple form of DOE, a binary phase grating with a period of 20.85 μm (σ = 0.5 μm), a groove depth and width of 0.7 μm (σ = 0.2 μm) and 8.8 μm (σ = 0.5 μm) respectively, was successfully machined in BK7. The topographic characteristics were measured by white light interferometry and scanning electron microscopy (SEM). The processing was carried out on high precision stages with an ultrafast fibre laser (350 fs) emitting a 343 nm pulse focused onto the sample with a stationary microscope objective. A diffracted efficiency of 27%, obtained with a spectro goniometer, was corroborated by the theoretical results obtained by the Fourier modal method (FMM), taking into account the measured topographic values. These encouraging results demonstrate that high-speed femtosecond laser manufacturing of DOE in bulk glasses can be achieved, opening the way to rapid prototyping of multi-layered-DOEs.

  18. EFFICACY OF KINESIO-TAPING VERSUS PHONOPHORESIS ON KNEE OSTEOARTHRITIS: AN EXPERIMENTAL STUDY

    Directory of Open Access Journals (Sweden)

    Magda Gaid Sedhom

    2016-08-01

    Full Text Available Background: Osteoarthritis (OA is the most common type of joint disease. Pain is the most common symptom of knee osteoarthritis. Also it characterized by sign, symptoms of inflammation, pain, stiffness and loss of mobility. This study was conducted to explore the efficacy of kinesio taping (KT versus Aescin, Diethylamine Salicylate gel phonophoresis (PH on pain level, range of motion (ROM, and proprioceptive accuracy on mild to moderate knee OA patients. Methods: Forty females with knee OA from Outpatient Clinic of Physical Therapy Faculty participated in the study with mean age (49±5.82 years. They were randomly assigned into 2 equal groups. Group I: received Aescin, Diethylamine Salicylate gel PH with pulsed ultrasound therapy and group II received KT. All patients received hot packs and selected exercise program for four weeks; three sessions per week. Visual analogue scale was used in assessment of pain level. Electronic digital goniometer was used in assessment of knee flexion ROM. Iso-kinetic daynamometer was used in assessment of knee proprioceptive accuracy. Results: There was a significant relieving of pain perception, increasing of knee flexion ROM and improving proprioceptive accuracy in knee joint post-study in both groups. But application of Aescin, Diethylamine Salicylate gel PH had significant relieve of knee pain than KT. Conclusion: Using of Aescin, Diethylamine Salicylate gel PH is more effective than KT application in reliving knee pain in knee osteoarthritic patients.

  19. Mesomorphic phase behaviour of low molar mass PEP-PDMS diblock copolymers synthesized by anionic polymerization

    International Nuclear Information System (INIS)

    Vigild, M.E.

    1997-10-01

    The phase behaviour of low molar mass poly(ethylene-alt-propylene) -poly(dimethylsiloxane) (PEP-PDMS) is investigated in this thesis by the combination of dynamical mechanical spectroscopy (rheology) to measure phase transition temperatures, and small-angle x-ray scattering to identify the morphology of encountered phases. Samples of PEP-PDMS in the range of 0.2-0.7 in volume fraction of PEP are studied. This diblock copolymer system exhibits the three classical phases of lamellar sandwich structure (LAM), hexagonally packed cylinders (HEX), and spheres arranged on a body centered cubic lattice (BCC). Furthermore the gyroid phase (Ia3d symmetry) of two interpenetrating networks was also identified as a stable phase of the PEP-PDMS system. Time resolved measurements of small-angle neutron scattering in tandem with simultaneous in-situ rheological measurements are performed on samples showing transitions between different ordered phases. The identification of especially the BCC and gyroid phases from scattering experiments is treated. By performing mesoscopic crystallographic measurements using a custom built goniometer it was unambiguously shown that the application of shear to an unoriented powder-like sample introduces uniaxial orientation of the gyroid phase. The orientation of the ordered phase is otherwise random, causing a two-dimensional powder. Finally this dissertation presents a discussion of relevant parameters for the description of diblock copolymer phase behaviour together with descriptions of anionic polymerization for the synthesis of copolymers, and various experimental techniques for the characterization of diblocks. (au)

  20. Mesomorphic phase behaviour of low molar mass PEP-PDMS diblock copolymers synthesized by anionic polymerization

    Energy Technology Data Exchange (ETDEWEB)

    Vigild, M.E.

    1997-10-01

    The phase behaviour of low molar mass poly(ethylene-alt-propylene) -poly(dimethylsiloxane) (PEP-PDMS) is investigated in this thesis by the combination of dynamical mechanical spectroscopy (rheology) to measure phase transition temperatures, and small-angle x-ray scattering to identify the morphology of encountered phases. Samples of PEP-PDMS in the range of 0.2-0.7 in volume fraction of PEP are studied. This diblock copolymer system exhibits the three classical phases of lamellar sandwich structure (LAM), hexagonally packed cylinders (HEX), and spheres arranged on a body centered cubic lattice (BCC). Furthermore the gyroid phase (Ia3d symmetry) of two interpenetrating networks was also identified as a stable phase of the PEP-PDMS system. Time resolved measurements of small-angle neutron scattering in tandem with simultaneous in-situ rheological measurements are performed on samples showing transitions between different ordered phases. The identification of especially the BCC and gyroid phases from scattering experiments is treated. By performing mesoscopic crystallographic measurements using a custom built goniometer it was unambiguously shown that the application of shear to an unoriented powder-like sample introduces uniaxial orientation of the gyroid phase. The orientation of the ordered phase is otherwise random, causing a two-dimensional powder. Finally this dissertation presents a discussion of relevant parameters for the description of diblock copolymer phase behaviour together with descriptions of anionic polymerization for the synthesis of copolymers, and various experimental techniques for the characterization of diblocks. (au). 9 tabs., 40 ills., 81 refs.

  1. Analysis of rocks particulates by VNIR spectroscopy with Ma_Miss instrument breadboard.

    Science.gov (United States)

    De Angelis, Simone; Altieri, Francesca; Giardino, Marco; Ammannito, Eleonora; Carli, Cristian; Frigeri, Alessandro; De Sanctis, Maria Cristina

    , reflectance spectra have been acquired on a set of six particulate rock samples, two carbonates and four volcanic rocks. All six rocks have been grinded in powders, then they’ve been separated in nine grain sizes in the range dvalues of the spectra acquired with the Ma_Miss breadboard, and we compared them with the laboratory spectro-goniometer data. The continuum slope has been calculated in three ranges: a VIS-slope (0.5-0.8 mum), a NIR-slope (1.2-1.8 mum), and a VNIR-slope (0.6 - 2.0 mum). The reflectance value has been evaluated in two distinct regions of the analysed spectra, at 0.8 mum and at 1.62 mum. Continuum slopes and reflectance values have been plotted in function of the grain size. The classical correlation between these parameters and the grain size has been observed with both setups: the slope and reflectances decrease with increasing grain size. Parameters derived from Ma_Miss breadboard measurements show a behaviour that is consistent with the trends observed from spectro-goniometer measurements. The reflectance values derived with the two setups are very similar. The trends relative to the slopes obtained with Ma_Miss data are more irregular, even if there is a general decreasing with increasing of the grain size, as expected. The differences observed in the continuum slopes as seen by the two instruments can be justified taking into account the different spatial resolutions, viewing geometries, the angular diameter of the source, and the ratio between the instrument spatial spot and the grain size.

  2. Efektivitas Desensitizing Agent dengan dan tanpa Fluor pada Metode in Office Bleaching terhadap Kandungan Mineral Gigi (Kajian In Vitro

    Directory of Open Access Journals (Sweden)

    Yulita Kristanti

    2015-12-01

    Full Text Available In office bleaching menggunakan hidrogen peroksida 40% sering memberikan efek samping berupa linu baik selama maupun setelah perawatan tersebut dilakukan. Penelitian ini dilakukan dengan tujuan untuk mengetahui pengaruh waktu aplikasi dan kandungan fluor desensitizing agent pada metode in office bleaching terhadap kandungan mineral gigi. Delapan gigi masing-masing dipotong menjadi 4 bagian, 6 potong digunakan untuk pemeriksaan XRD awal. Gigi dikeringkan dalam oven suhu 50° selama 30 menit diserbuk, diambil 1 mg untuk diperiksa kandungan mineralnya dengan goniometer. Dua puluh empat potong yang lain dibagi dalam 4 kelompok perlakuan. Kelompok I: gigi diaplikasi bahan bleaching 0,5-1 mm hidrogen peroksida 40% selama 1 jam, dicuci, dikeringkan, diikuti aplikasi 0,1 ml desensitizing agent tanpa fluor (CPP-ACP selama 30 menit, dicuci, dikeringkan. Kelompok II : gigi diaplikasi CPP-ACP 30 menit, dicuci, dikeringkan, dibleaching menggunakan hidrogen peroksida 40% selama 1 jam. Selanjutnya gigi diaplikasi CPP-ACP 30 menit lagi, dicuci, dikeringkan. Kelompok III gigi dibleaching menggunakan hidrogen peroksida 40% selama 1 jam, dicuci, dikeringkan, diikuti aplikasi desensitizing agent yang mengandung fluor (CPP-ACFP selama 30 menit, dicuci, dikeringkan. Kelompok IV: gigi diaplikasi CPP-ACFP 30 menit, dicuci, dikeringkan, dibleaching menggunakan hidrogen peroksida 40% selama 1 jam. Selanjutnya gigi diaplikasi CPP-ACFP selama 30 menit, dicuci dikeringkan. Sesudah perlakuan, semua gigi dilakukan pemeriksaan kandungan mineral gigi dengan prosedur yang sama. Uji Mann Whitney menunjukkan penurunan mineral paling sedikit terjadi pada kelompok IV (4500. Desensitizing agent mengandung F sebelum dan sesudah perlakuan in office bleaching menunjukkan penurunan mineral paling kecil.   The Effectiveness of Desensitizing Agent with and without Fluorine in Office Bleaching Method to Tooth Mineral content. Tooth sensitivity arises during or after an in

  3. EFFECTIVENESS OF PNF STRETCHING VERSUS STATIC STRETCHING ON PAIN AND HAMSTRING FLEXIBILITY FOLLOWING MOIST HEAT IN INDIVIDUALS WITH KNEE OSTEOARTHRITIS

    Directory of Open Access Journals (Sweden)

    Meena .V

    2016-10-01

    Full Text Available Background: Osteoarthritis (OA is a degenerative joint disease and one of the major public health problem that causesfunctional impairment and reduced quality of life. To compare the effectiveness of PNF Hold relax stretching versus Static stretching on pain and flexibility of hamstring following moist heat in individuals with knee osteoarthritis. Hamstring tightness is the major problem in knee osteoarthritis individuals. Therefore the need of study is comparing the effectiveness of PNF Hold relax stretching versus static stretching on pain and flexibility of hamstrings following moist heat in knee osteoarthritis participants. Determining the effects of PNF Hold relax stretching versus Static stretching along with moist heat on pain and hamstring flexibility by VAS and Active knee extension range of motion in knee osteoarthritis individuals. Methods: 30 subjects with symptoms of knee osteoarthritis were randomly distributed into 2 groups 15 in each group. PNF Hold relax stretching along with moist heat is compared to Static stretching along with moist heat. Pain was measured by Visual Analogue Scale (VAS and hamstring flexibility by Active knee Extension Range of Motion (AKEROM by universal goniometer. Measurements are taken pre and post intervention. Results: The results indicated PNF Hold relax stretching along with moist heat showed a statistically significant improvement in pain (p<0.05 and improvement in hamstring flexibility (p<0.05 when compared to Static stretching along with moist heat. Conclusion: Subjects with PNF Hold relax stretching along with moist heat showed significant improvement in pain reduction and improving hamstring flexibility than Static stretching along with moist heat.

  4. Application of Phase Shifting Projection Moire on Solid Regular Figures and Plant Organs Three Dimensional Digital Model Generation

    Science.gov (United States)

    Lino, A. C. L.; Dal Fabbro, I. M.

    2008-04-01

    The conception of a tridimensional digital model of solid figures and plant organs started from topographic survey of virtual surfaces [1], followed by topographic survey of solid figures [2], fruit surface survey [3] and finally the generation of a 3D digital model [4] as presented by [1]. In this research work, i.e. step number [4] tested objects included cylinders, cubes, spheres and fruits. A Ronchi grid named G1 was generated in a PC, from which other grids referred as G2, G3, and G4 were set out of phase by 1/4, 1/2 and 3/4 of period from G1. Grid G1 was then projected onto the samples surface. Projected grid was named Gd. The difference between Gd and G1 followed by filtration generated de moiré fringes M1 and so on, obtaining the fringes M2, M3 and M4 from Gd. Fringes are out of phase one from each other by 1/4 of period, which were processed by the Rising Sun Moiré software to produce packed phase and further on, the unpacked fringes. Tested object was placed on a goniometer and rotate to generate four surfaces topography. These four surveyed surfaces were assembled by means of a SCILAB software, obtaining a three column matrix, corresponding to the object coordinates xi, also having elevation values and coordinates corrected as well. The work includes conclusions on the reliability of the proposed method as well as the setup simplicity and of low cost.

  5. Shoulder Dynamic Control Ratio and Rotation Range of Motion in Female Junior Elite Handball Players and Controls.

    Science.gov (United States)

    van Cingel, Robert; Habets, Bas; Willemsen, Linn; Staal, Bart

    2018-03-01

    To compare glenohumeral range of motion and shoulder rotator muscle strength in healthy female junior elite handball players and controls. Cross-sectional case-control study. Sports medical center. Forty elite female handball players and 30 controls active in nonoverhead sports participated in this study. Passive external rotator (ER), internal rotator (IR), and total range of motion (TROM) of the dominant and nondominant arm were examined with a goniometer. An isokinetic dynamometer was used to evaluate concentric and eccentric rotator muscle strength at 60 and 120 degrees/s with dynamic control ratio (DCR = ERecc:IRcon) as the main outcome parameter. Except for the ER range of motion in the nondominant arm, no significant differences were found between groups for IR, ER of the dominant arm, and the TROM. Within the handball group, the side-to-side difference for IR of the dominant arm was -1.4 degrees. The ER and the TROM of the dominant arm were significantly larger, 6.3 and 4.9 degrees, respectively. For both groups, the DCR values were above 1 and no significant differences were found between the dominant and nondominant arm. The DCR values in the handball group were significantly lower than in the control group. Based on the adopted definitions for muscle imbalance, glenohumeral internal range of motion deficit and TROM deficit our elite female handball players seem not at risk for shoulder injuries. Prospective studies are needed to support the belief that a DCR below 1 places the shoulder at risk for injury.

  6. In-situ Study of Seating Static Comfort in Passenger Vehicles

    Directory of Open Access Journals (Sweden)

    Seraj Umi Salmah

    2018-01-01

    Full Text Available In today’s automotive market, comfort is huge selling point of a vehicle. Priority is given by buyers to how comfortable a seat feels during purchase decisions. The measure of comfort is harmonious mix of many aspects such as human ergonomics and physiological factors. However, a gap still exists between objective and subjective measures due to lack of emphasis by past researchers. This is particularly obvious in the lumbar support feature that has still not been able to address the health problems related to driving. This project focuses on bridging the gap by giving users the ability to define true preferred posture in realistic settings. This is done by the creation of a apparatus that allows users to individually manipulate the seat contour for optimum support in more segments than just lumbar area. The experiment is performed in 3 parts, where in each part different segments of the apparatus are manipulatable (lumbar segment, sacral & thoracic segment, and all segments. Sixty human subjects’ statistics are recorded (gender, age, BMI and height and the subjects are palpated to locate internal joints. These joints are marked and postural angles between them are measured using a goniometer. In each seat configuration, the angles are measured and a comfort rating is taken to be compared. It was found that the posture angles are different among the 3 experiments, and there is a change in comfort felt. Some human factors have also been proven to contribute heavily to angles chosen by occupants.

  7. A 2-100 keV, UHV ion impact spectrometer for ion-solid interaction studies

    International Nuclear Information System (INIS)

    Berg, J.A. Van den; Armour, D.G.; Verheij, L.K.

    1978-01-01

    A 2 to 100 keV ion accelerator has been constructed as part of an ion impact spectrometer in which a number of analytical techniques have been combined to allow a comprehensive study of the interaction of low- and medium-energy ions with solids to be carried out under carefully controlled conditions. The overall requirements of the ion beam system in terms of ion species, beam purity, uniformity, energy spread and intensity were dictated by the interest in carrying out low-energy ion scattering, Rutherford back-scattering and thermal desorption experiments. The accelerator design utilises the principle of low-energy extraction and mass analysis, and post-acceleration up to the required high energy. The ions are produced in a duoplasmatron ion source and a parallel beam is obtained after mass selection, utilising a quadrupole triplet lens in conjunction with a 60 0 stigmatic focusing magnetic analyser. Proton and rare gas ion beams of 1 to 100 nA are routinely obtained on target. The 54 cm diameter, UHV target chamber is pumped by a 270 1 s -1 turbo-molecular pump in conjunction with an in-line titanium sublimator, and typical base pressures of 1 to 4 x 10 -11 Torr are achieved. The target is supported in a precision, three-axis goniometer and the detection system, at present comprising a 90 mm mean diameter hemispherical energy analyser and channel electron multiplier, is mounted on a two-axis manipulator. Preliminary measurements using the system have employed the low-energy ion scattering technique to study the oxidation of a Ni(110) surface. (author)

  8. Experimental studies of contact angle hysteresis phenomena on polymer surfaces – Toward the understanding and control of wettability for different applications.

    Science.gov (United States)

    Grundke, K; Pöschel, K; Synytska, A; Frenzel, R; Drechsler, A; Nitschke, M; Cordeiro, A L; Uhlmann, P; Welzel, P B

    2015-08-01

    Contact angle hysteresis phenomena on polymer surfaces have been studied by contact angle measurements using sessile liquid droplets and captive air bubbles in conjunction with a drop shape method known as Axisymmetric Drop Shape Analysis - Profile (ADSA-P). In addition, commercially available sessile drop goniometer techniques were used. The polymer surfaces were characterized with respect to their surface structure (morphology, roughness, swelling) and surface chemistry (elemental surface composition, acid-base characteristics) by scanning electron microscopy (SEM), scanning force microscopy (SFM), ellipsometry, X-ray photoelectron spectroscopy (XPS) and streaming potential measurements. Heterogeneous polymer surfaces with controlled roughness and chemical composition were prepared by different routes using plasma etching and subsequent dip coating or grafting of polymer brushes, anodic oxidation of aluminium substrates coated with thin polymer films, deposition techniques to create regular patterned and rough fractal surfaces from core-shell particles, and block copolymers. To reveal the effects of swelling and reorientation at the solid/liquid interface contact angle hysteresis phenomena on polyimide surfaces, cellulose membranes, and thermo-responsive hydrogels have been studied. The effect of different solutes in the liquid (electrolytes, surfactants) and their impact on contact angle hysteresis were characterized for solid polymers without and with ionizable functional surface groups in aqueous electrolyte solutions of different ion concentrations and pH and for photoresist surfaces in cationic aqueous surfactant solutions. The work is an attempt toward the understanding of contact angle hysteresis phenomena on polymer surfaces aimed at the control of wettability for different applications. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Test-retest reliability of jump execution variables using mechanography: a comparison of jump protocols.

    Science.gov (United States)

    Fitzgerald, John S; Johnson, LuAnn; Tomkinson, Grant; Stein, Jesse; Roemmich, James N

    2018-05-01

    Mechanography during the vertical jump may enhance screening and determining mechanistic causes underlying physical performance changes. Utility of jump mechanography for evaluation is limited by scant test-retest reliability data on force-time variables. This study examined the test-retest reliability of eight jump execution variables assessed from mechanography. Thirty-two women (mean±SD: age 20.8 ± 1.3 yr) and 16 men (age 22.1 ± 1.9 yr) attended a familiarization session and two testing sessions, all one week apart. Participants performed two variations of the squat jump with squat depth self-selected and controlled using a goniometer to 80º knee flexion. Test-retest reliability was quantified as the systematic error (using effect size between jumps), random error (using coefficients of variation), and test-retest correlations (using intra-class correlation coefficients). Overall, jump execution variables demonstrated acceptable reliability, evidenced by small systematic errors (mean±95%CI: 0.2 ± 0.07), moderate random errors (mean±95%CI: 17.8 ± 3.7%), and very strong test-retest correlations (range: 0.73-0.97). Differences in random errors between controlled and self-selected protocols were negligible (mean±95%CI: 1.3 ± 2.3%). Jump execution variables demonstrated acceptable reliability, with no meaningful differences between the controlled and self-selected jump protocols. To simplify testing, a self-selected jump protocol can be used to assess force-time variables with negligible impact on measurement error.

  10. Radiative transfer modeling of dust-coated Pancam calibration target materials: Laboratory visible/near-infrared spectrogoniometry

    Science.gov (United States)

    Johnson, J. R.; Sohl-Dickstein, J.; Grundy, W.M.; Arvidson, R. E.; Bell, J.F.; Christensen, P.R.; Graff, T.; Guinness, E.A.; Kinch, K.; Morris, Robert; Shepard, M.K.

    2006-01-01

    Laboratory visible/near-infrared multispectral observations of Mars Exploration Rover Pancam calibration target materials coated with different thicknesses of Mars spectral analog dust were acquired under variable illumination geometries using the Bloomsburg University Goniometer. The data were fit with a two-layer radiative transfer model that combines a Hapke formulation for the dust with measured values of the substrate interpolated using a He-Torrance approach. We first determined the single-scattering albedo, phase function, opposition effect width, and amplitude for the dust using the entire data set (six coating thicknesses, three substrates, four wavelengths, and phase angles 3??-117??). The dust exhibited single-scattering albedo values similar to other Mars analog soils and to Mars Pathfinder dust and a dominantly forward scattering behavior whose scattering lobe became narrower at longer wavelengths. Opacity values for each dust thickness corresponded well to those predicted from the particles sizes of the Mars analog dust. We then restricted the number of substrates, dust thicknesses, and incidence angles input to the model. The results suggest that the dust properties are best characterized when using substrates whose reflectances are brighter and darker than those of the deposited dust and data that span a wide range of dust thicknesses. The model also determined the dust photometric properties relatively well despite limitations placed on the range of incidence angles. The model presented here will help determine the photometric properties of dust deposited on the MER rovers and to track the multiple episodes of dust deposition and erosion that have occurred at both landing sites. Copyright 2006 by the American Geophysical Union.

  11. Immobilization of immunoglobulin G in a highly oriented manner on a protein-A terminated multilayer system

    Energy Technology Data Exchange (ETDEWEB)

    Zengin, Adem [Department of Chemistry, Faculty of Art and Science, Gazi University, 06500 Besevler, Ankara (Turkey); Caykara, Tuncer, E-mail: caykara@gazi.edu.tr [Department of Chemistry, Faculty of Art and Science, Gazi University, 06500 Besevler, Ankara (Turkey)

    2011-01-01

    In this study, we have fabricated a multilayer system consisting of 3-glycidoxypropyldimethylmethoxysilane (GPDS), poly(dimethylsiloxane) bis 3-aminopropyl terminated (PDMS) and protein-A on a silicon wafer surface for oriented immobilization of immunoglobilin G (IgG). The multilayer system with a different component in each layer was characterized by ellipsometry, contact-angle goniometer, X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM) and fluorescence microscopy. The epoxy-terminated monolayer was formed by the chemisorption of GPDS molecules on the hydroxylated silicon surface. The PDMS film about 4.5 nm thick was produced on the GPDS-monolayer by the chemical reaction between the amine groups at the end of PDMS chain and the epoxy groups of GPDS molecules. By introducing the PDMS chains, the hydrophilic character of GPDS-monolayer decreased. Study of the time dependence of polymer grafting showed that the chemisorption of GPDS is fast, whereas at least 16 h is needed to generate the homogeneous PDMS layer. For immobilization of IgG molecules in a highly oriented manner, protein-A molecules were first chemically bound to an ultrathin ({approx}4.5 nm) PDMS reactive polymer layer and later used to capture IgG. It was shown that the existence of protein-A in the multilayer system has a strong influence on the binding properties of IgG not only in the efficiency of binding, but also in its specificity. In conclusion, the multilayer system with protein-A has the potential to be further developed into an efficient immunoassay protein chip.

  12. Morphological aspects of myocardial bridges.

    Science.gov (United States)

    Lujinović, Almira; Kulenović, Amela; Kapur, Eldan; Gojak, Refet

    2013-11-01

    Although some myocardial bridges can be asymptomatic, their presence often causes coronary disease either through direct compression of the "tunnel" segment or through stimulation and accelerated development of atherosclerosis in the segment proximally to the myocardial bridge. The studied material contained 30 human hearts received from the Department of Anatomy. The hearts were preserved 3 to 5 days in 10% formalin solution. Thereafter, the fatty tissue was removed and arterial blood vessels prepared by careful dissection with special reference to the presence of the myocardial bridges. Length and thickness of the bridges were measured by the precise electronic caliper. The angle between the myocardial bridge fibre axis and other axis of the crossed blood vessel was measured by a goniometer. The presence of the bridges was confirmed in 53.33% of the researched material, most frequently (43.33%) above the anterior interventricular branch. The mean length of the bridges was 14.64 ± 9.03 mm and the mean thickness was 1.23 ± 1.32 mm. Myocardial bridge fibres pass over the descending blood vessel at the angle of 10-90 degrees. The results obtained on a limited sample suggest that the muscular index of myocardial bridge is the highest for bridges located on RIA, but that the difference is not significant in relation to bridges located on other branches. The results obtained suggest that bridges located on other branches, not only those on RIA, could have a great contractive power and, consequently, a great compressive force, which would be exerted on the wall of a crossed blood vessel.

  13. Physical basics of endovenous laser treatment and potential of innovative developments

    Science.gov (United States)

    Sroka, R.; Esipova, A.; Schmedt, C. G.

    2017-04-01

    During the last decade, endoluminal laser treatment (ELT) has been rapidly developing. Protocols using radially emitting ELT fibres in combination with infrared laser light show clinical advantages over the bare-fibre technique and near infrared irradiation. Although the clinical response rate is high several side effects occurred. Innovative light application systems and feedback systems are therefore being under development to potentially improve the clinical situation. The irradiation patterns of bare fibres and radially emitting 1-ring and 2-ring fibres were measured using the goniometer technique. The device robustness, device handling and tissue effects were investigated using the established ox-foot-model. Furthermore, temperature measurements were performed either intraluminal within the irradiation field using a tiny temperature sensor and on the outer surface of the vessel wall by means of a thermocamera. All fibres showed sufficient mechanical and thermal robustness. The destruction threshold is far beyond the light powers employed during clinical application. The 1-ring fibre showed very high peak temperatures for a short time, while the 2-ring-fibre hold its somewhat lower maximum temperature for a longer time. Both forms of energy application resulted in the desired shrinkage and destruction effect. In this regard, the handling of the 2-ring fibre appears subjectively more convenient with reduced sticking-related problems. Acute tissue effects could be investigated to improve the understanding especially of the interaction between handling, maneuvers and tissue effects. The 2-ring radially emitting fibre in combination with IR laser light and specific application parameters showed improved handling and safety features.

  14. Sex differences in task distribution and task exposures among Danish house painters: an observational study combining questionnaire data with biomechanical measurements.

    Directory of Open Access Journals (Sweden)

    Thomas Heilskov-Hansen

    Full Text Available OBJECTIVES: Sex differences in occupational biomechanical exposures may be part of the explanation why musculoskeletal complaints and disorders tend to be more common among women than among men. We aimed to determine possible sex differences in task distribution and task-specific postures and movements of the upper extremities among Danish house painters, and to establish sex-specific task exposure matrices. METHODS: To obtain task distributions, we sent out a questionnaire to all members of the Painters' Union in Denmark (N = 9364, of whom 53% responded. Respondents reported their task distributions in a typical week. To obtain task exposures, postures and movements were measured in 25 male and 25 female house painters for one whole working day per person. We used goniometers on the wrists, and inclinometers on the forehead and the upper arms. Participants filled in a logbook allowing task-specific exposures to be identified. Percentiles and % time with non-neutral postures were used to characterise postures. Velocity, range of motion, repetitiveness, and variation were used as measures of movement. Cochran-Mantel-Haenszel statistics and unpaired double-sided t-tests with post-hoc Bonferroni correction were used to evaluate sex differences. RESULTS: Statistically significant (p<0.05 sex differences were revealed in task proportions, but the proportions differed by less than 4%. For task exposures, no statistically significant sex differences were found. CONCLUSIONS: Only minor sex differences were found in task distribution and task exposures regarding postures and movements among Danish house painters. Sex-specific task exposure matrices were established.

  15. Analysis of risk factors for neuropathic foot ulceration in diabetes mellitus.

    Science.gov (United States)

    Bennett, P J; Stocks, A E; Whittam, D J

    1996-03-01

    Diabetes mellitus affects about one in 25 Australians. Neuropathic foot ulceration is a frequent complication in persons with diabetes. This study evaluates the importance of different risk factors for the development of this condition. The role of nonenzymatic glycosylation and pressure beneath the sole of the foot in the pathogenesis of neuropathic foot ulcers was investigated. Twenty-seven subjects with diabetes with a recent history of neuropathic foot ulceration were matched by age and sex with a group of 50 control subjects without neuropathy or history of foot ulceration. The degree of nonenzymatic glycosylation was assessed by analyzing the average level of glycosylated hemoglobin in the 3 years prior to the development of the foot ulcer and a goniometer assessment of peripheral joint (hand and ankle) flexibility. Dynamic pressure of the plantar aspect of the foot was recorded using a Musgrave Footprint System pedobarograph during a normal gait cycle. There was no significant difference in age, sex, body mass index, and duration or type of diabetes between the ulcer and control groups. The pressure of the plantar aspect of the foot was significantly elevated (p < 0.01). Ankle joint flexibility was reduced (p < 0.01) in cases with neuropathic foot ulceration compared with the control group. There was a trend toward elevation of glycosylated hemoglobin (HbA1c fraction) or HbA1c in the ulcer group (p = 0.06). The results suggested that nonenzymatic glycosylation occurs at a more significant level in patients with diabetes with a history of neuropathic foot ulceration.

  16. Quantification of Staphylococcus aureus adhesion forces on various dental restorative materials using atomic force microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Merghni, Abderrahmen, E-mail: abderrahmen_merghni@yahoo.fr [Laboratoire des Maladies Transmissibles et Substances biologiquement actives (LR99ES27) Faculté de Pharmacie de Monastir, Université de Monastir (Tunisia); Kammoun, Dorra [Laboratoire de Biomatériaux et Biotechnologie, Faculté de Médecine Dentaire, Monastir (Tunisia); Hentati, Hajer [Laboratoire de Recherche en Santé Orale et Réhabilitation Bucco-Faciale (LR12ES11), Faculté de Médecine Dentaire de Monastir, Université de Monastir (Tunisia); Janel, Sébastien [BioImaging Center Lille-FR3642, Lille (France); Popoff, Michka [Cellular Microbiology and Physics of Infection-CNRS UMR8204, INSERM U1019, Institut Pasteur de Lille, Lille University (France); Lafont, Frank [BioImaging Center Lille-FR3642, Lille (France); Cellular Microbiology and Physics of Infection-CNRS UMR8204, INSERM U1019, Institut Pasteur de Lille, Lille University (France); Aouni, Mahjoub [Laboratoire des Maladies Transmissibles et Substances biologiquement actives (LR99ES27) Faculté de Pharmacie de Monastir, Université de Monastir (Tunisia); Mastouri, Maha [Laboratoire des Maladies Transmissibles et Substances biologiquement actives (LR99ES27) Faculté de Pharmacie de Monastir, Université de Monastir (Tunisia); Laboratoire de Microbiologie, CHU Fattouma Bourguiba de Monastir (Tunisia)

    2016-08-30

    Highlights: • 4 dental restorative materials were characterized for roughness, angle contact water and surface free energy. • AFM adhesion forces of S. aureus to tested materials were achieved in presence and absence of salivary conditioning film. • S. aureus initial adhesion is dependent on the surface free energy and roughness. - Abstract: In the oral cavity dental restorative biomaterials can act as a reservoir for infection with opportunistic Staphylococcus aureus pathogen, which can lead to the occurrence of secondary caries and treatment failures. Our aim was to evaluate the adhesion forces by S. aureus on four dental restorative biomaterials and to correlate this finding to differences in specific surface characteristics. Additionally, the influence of salivary conditioning films in exerted adhesion forces was investigated. The substrate hydrophobicity was measured by goniometer and the surface free energy was calculated using the equilibrium advancing contact angle values of water, formamide, and diiodomethane on the tested surfaces. The surface roughness was determined using atomic force microscope (AFM). Additionally, cell force spectroscopy was achieved to quantify the forces that drive cell-substrate interactions. S. aureus bacterium exerted a considerable adhesion forces on various dental restorative materials, which decreased in the presence of saliva conditioning film. The influence of the surface roughness and free energy in initial adhesion appears to be more important than the effect of hydrophobicity, either in presence or absence of saliva coating. Hence, control of surface properties of dental restorative biomaterials is of crucial importance in preventing the attachment and subsequent the biofilm formation.

  17. The effect of aluminium nanocoating and water pH value on the wettability behavior of an aluminium surface

    Science.gov (United States)

    Ali, Naser; Teixeira, Joao A.; Addali, Abdulmajid; Al-Zubi, Feras; Shaban, Ehab; Behbehani, Ismail

    2018-06-01

    Experimental investigation was performed to highlight the influence of ionic bounding and surface roughness effects on the surface wettability. Nanocoating technique via e-beam physical vapor deposition process was used to fabricate aluminium (Al) film of 50, 100, and 150 nm on the surface of an Al substrate. Microstructures of the samples before and after deposition were observed using an atomic force microscopy. A goniometer device was later on used to examine the influence of surface topography on deionised water of pH 4, 7 and 9 droplets at a temperature ranging from 10 °C to 60 °C through their contact angles with the substrate surface, for both coated and uncoated samples. It was found that, although the coated layer has reduced the mean surface roughness of the sample from 10.7 nm to 4.23 nm, by filling part of the microstructure gaps with Al nanoparticles, the wettability is believed to be effected by the ionic bounds between the surface and the free anions in the fluid. As the deionised water of pH 4, and 9 gave an increase in the average contact angles with the increase of the coated layer thickness. On the other hand, the deionised water of pH 7 has showed a negative relation with the film thickness, where the contact angle reduced as the thickness of the coated layer was increased. The results from the aforementioned approach had showed that nanocoating can endorse the hydrophobicity (unwitting) nature of the surface when associated with free ions hosted by the liquid.

  18. High resolution 3D imaging of synchrotron generated microbeams

    Energy Technology Data Exchange (ETDEWEB)

    Gagliardi, Frank M., E-mail: frank.gagliardi@wbrc.org.au [Alfred Health Radiation Oncology, The Alfred, Melbourne, Victoria 3004, Australia and School of Medical Sciences, RMIT University, Bundoora, Victoria 3083 (Australia); Cornelius, Iwan [Imaging and Medical Beamline, Australian Synchrotron, Clayton, Victoria 3168, Australia and Centre for Medical Radiation Physics, University of Wollongong, Wollongong, New South Wales 2500 (Australia); Blencowe, Anton [Division of Health Sciences, School of Pharmacy and Medical Sciences, The University of South Australia, Adelaide, South Australia 5000, Australia and Division of Information Technology, Engineering and the Environment, Mawson Institute, University of South Australia, Mawson Lakes, South Australia 5095 (Australia); Franich, Rick D. [School of Applied Sciences and Health Innovations Research Institute, RMIT University, Melbourne, Victoria 3000 (Australia); Geso, Moshi [School of Medical Sciences, RMIT University, Bundoora, Victoria 3083 (Australia)

    2015-12-15

    Purpose: Microbeam radiation therapy (MRT) techniques are under investigation at synchrotrons worldwide. Favourable outcomes from animal and cell culture studies have proven the efficacy of MRT. The aim of MRT researchers currently is to progress to human clinical trials in the near future. The purpose of this study was to demonstrate the high resolution and 3D imaging of synchrotron generated microbeams in PRESAGE® dosimeters using laser fluorescence confocal microscopy. Methods: Water equivalent PRESAGE® dosimeters were fabricated and irradiated with microbeams on the Imaging and Medical Beamline at the Australian Synchrotron. Microbeam arrays comprised of microbeams 25–50 μm wide with 200 or 400 μm peak-to-peak spacing were delivered as single, cross-fire, multidirectional, and interspersed arrays. Imaging of the dosimeters was performed using a NIKON A1 laser fluorescence confocal microscope. Results: The spatial fractionation of the MRT beams was clearly visible in 2D and up to 9 mm in depth. Individual microbeams were easily resolved with the full width at half maximum of microbeams measured on images with resolutions of as low as 0.09 μm/pixel. Profiles obtained demonstrated the change of the peak-to-valley dose ratio for interspersed MRT microbeam arrays and subtle variations in the sample positioning by the sample stage goniometer were measured. Conclusions: Laser fluorescence confocal microscopy of MRT irradiated PRESAGE® dosimeters has been validated in this study as a high resolution imaging tool for the independent spatial and geometrical verification of MRT beam delivery.

  19. COMPARISON OF METHODS FOR GEOMETRIC CAMERA CALIBRATION

    Directory of Open Access Journals (Sweden)

    J. Hieronymus

    2012-09-01

    Full Text Available Methods for geometric calibration of cameras in close-range photogrammetry are established and well investigated. The most common one is based on test-fields with well-known pattern, which are observed from different directions. The parameters of a distortion model are calculated using bundle-block-adjustment-algorithms. This methods works well for short focal lengths, but is essentially more problematic to use with large focal lengths. Those would require very large test-fields and surrounding space. To overcome this problem, there is another common method for calibration used in remote sensing. It employs measurements using collimator and a goniometer. A third calibration method uses diffractive optical elements (DOE to project holograms of well known pattern. In this paper these three calibration methods are compared empirically, especially in terms of accuracy. A camera has been calibrated with those methods mentioned above. All methods provide a set of distortion correction parameters as used by the photogrammetric software Australis. The resulting parameter values are very similar for all investigated methods. The three sets of distortion parameters are crosscompared against all three calibration methods. This is achieved by inserting the gained distortion parameters as fixed input into the calibration algorithms and only adjusting the exterior orientation. The RMS (root mean square of the remaining image coordinate residuals are taken as a measure of distortion correction quality. There are differences resulting from the different calibration methods. Nevertheless the measure is small for every comparison, which means that all three calibration methods can be used for accurate geometric calibration.

  20. Influence of nanoparticles on filterability of fruit-juice industry wastewater using submerged membrane bioreactor.

    Science.gov (United States)

    Demirkol, Guler Turkoglu; Dizge, Nadir; Acar, Turkan Ormanci; Salmanli, Oyku Mutlu; Tufekci, Nese

    2017-07-01

    In this study, polyethersulfone (PES) ultrafiltration membrane surface was modified with nano-sized zinc oxide (nZnO) and silver (nAg) to improve the membrane filterability of the mixed liquor and used to treat fruit-juice industry wastewater in a submerged membrane bioreactor (MBR). The nAg was synthesized using three different methods. In the first method, named as nAg-M1, PES membrane was placed on the membrane module and nAg solution was passed through the membrane for 24 h at 25 ± 1 °C. In the second method, named as nAg-M2, PES membrane was placed in a glass container and it was shaken for 24 h at 150 rpm at 25 ± 1 °C. In the third method, named as nAg-M3, Ag nanoparticles were loaded onto PES membrane in L-ascorbic acid solution (0.1 mol/L) at pH 2 for 24 h at 150 rpm at 25 ± 1 °C. For the preparation of nZnO coated membrane, nZnO nanoparticles solution was passed through the membrane for 24 h at 25 ± 1 °C. Anti-fouling performance of pristine and coated membranes was examined using the submerged MBR. The results showed that nZnO and nAg-M3 membranes showed lower flux decline compared with pristine membrane. Moreover, pristine and coated PES membranes were characterized using a permeation test, contact angle goniometer, and scanning electron microscopy.

  1. Biomechanical Reconstruction Using the Tacit Learning System: Intuitive Control of Prosthetic Hand Rotation.

    Science.gov (United States)

    Oyama, Shintaro; Shimoda, Shingo; Alnajjar, Fady S K; Iwatsuki, Katsuyuki; Hoshiyama, Minoru; Tanaka, Hirotaka; Hirata, Hitoshi

    2016-01-01

    Background: For mechanically reconstructing human biomechanical function, intuitive proportional control, and robustness to unexpected situations are required. Particularly, creating a functional hand prosthesis is a typical challenge in the reconstruction of lost biomechanical function. Nevertheless, currently available control algorithms are in the development phase. The most advanced algorithms for controlling multifunctional prosthesis are machine learning and pattern recognition of myoelectric signals. Despite the increase in computational speed, these methods cannot avoid the requirement of user consciousness and classified separation errors. "Tacit Learning System" is a simple but novel adaptive control strategy that can self-adapt its posture to environment changes. We introduced the strategy in the prosthesis rotation control to achieve compensatory reduction, as well as evaluated the system and its effects on the user. Methods: We conducted a non-randomized study involving eight prosthesis users to perform a bar relocation task with/without Tacit Learning System support. Hand piece and body motions were recorded continuously with goniometers, videos, and a motion-capture system. Findings: Reduction in the participants' upper extremity rotatory compensation motion was monitored during the relocation task in all participants. The estimated profile of total body energy consumption improved in five out of six participants. Interpretation: Our system rapidly accomplished nearly natural motion without unexpected errors. The Tacit Learning System not only adapts human motions but also enhances the human ability to adapt to the system quickly, while the system amplifies compensation generated by the residual limb. The concept can be extended to various situations for reconstructing lost functions that can be compensated.

  2. Microcharacterization of interplanetary dust collected in the earth's stratosphere

    International Nuclear Information System (INIS)

    Fraundorf, P.B.

    1980-01-01

    This thesis involved an examination of the internal structure of thirteen 10 μm aggregates using selected techniques from the field now known as analytical electron microscopy. The aggregates were collected in the earth's stratosphere at 20 km altitude by impactors mounted on NASA U-2 aircraft. Eleven of them exhibited relative major element abundances similar to those found in chondritic meteorities. For this and other reasons, these eleven particles are believed to represent relatively-unaltered interplanetary dust. Interplanetary dust is thought to be of cometary origin, and comets in turn provide the most promising reservoir for unaltered samples of materials present during the collapse of the solar nebula. This thesis shows that the chondritic aggregates probably contain important information on a wide range of processes in the early solar system. In the course of this study, significant developments were necessary in the techniques of analysis for: (i) selected area electron diffraction (SAED) data; (ii) energy dispersive x-ray spectra; and (iii) spatial heterogeneity in geological materials. These developments include a method for analysing single crystal SAED patterns using spherical geometry. The method makes possible much more efficient use of diffraction data taken with a goniometer specimen stage. It allows major portions of the analysis to be done by a microprocessor, and it has potential for a wide range of on-line applications. Also, a comprehensive approach to the study of point-to-point heterogeneity in geological materials was developed. Some statistical, comparative, petrographic, and physical applications are described in the thesis

  3. Aging of oxygen and hydrogen plasma discharge treated a-C:H and ta-C coatings

    Science.gov (United States)

    Bachmann, Svenja; Schulze, Marcus; Morasch, Jan; Hesse, Sabine; Hussein, Laith; Krell, Lisa; Schnagl, Johann; Stark, Robert W.; Narayan, Suman

    2016-05-01

    Surface modification with gas plasma is an efficient and easy way to improve the surface energy and the tribological behavior of diamond-like carbon (DLC) coatings, e.g., in biomedical implants or as protective coatings. However, the long-term performance of the plasma treated DLC coatings is not fully clear. We thus studied the long-term stability of two kinds of DLC coatings, namely (a) hydrogenated amorphous carbon (a-C:H) and (b) tetrahedral amorphous carbon (ta-C) treated at different radio frequency (RF) power and time of oxygen (O2) and hydrogen (H2) plasma. Their surface properties, e.g. surface wettability, structure and tribological behavior, were studied at regular intervals for a period of two months using contact angle goniometer, Raman spectroscopy, X-ray photoelectron spectroscopy (XPS), lateral force microscopy (LFM) and ball on disc apparatus. The surface energy of both the coatings decreased upon aging. The higher the RF power and time of treatment, the higher was the hydrophobicity upon aging. XPS analysis showed that the increase in hydrophobicity could be due to adsorption of unavoidable volatile organic components in the atmosphere. The H2 plasma treated ta-C was capable of rearranging its structural bonds upon aging. The nano-friction measurements by LFM showed that the coefficient of friction of plasma treated a-C:H and ta-C decreased upon aging. The results indicate that the surface properties of plasma treated a-C:H and ta-C are not stable on long-term and are influenced by the environmental conditions.

  4. [Characteristics of Dupuytren's disease in women. A study of 67 cases].

    Science.gov (United States)

    Ferry, N; Lasserre, G; Pauchot, J; Lepage, D; Tropet, Y

    2013-12-01

    The aim of this study was to identify the clinical differences of the Dupuytren's disease in gender. Testosterone induces an increase of the Dupuytren's fibroblast proliferation via androgen's receptors. Testosterone rate increases during pregnancy and menopausis. We also reached a link between this factors and the clinical aspects of Dupuytren' disease in the women of our study. This retrospective, comparative study was about all women and a randomized number of men, who underwent surgery for Dupuytren' disease between 1980 and 2010. We analysed all the epidemiologic and clinical data, the surgery procedures and the complications. Pre- and postoperative measurements of the extension lack of all the joints were performed with a manual goniometer. Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire was used to evaluate the patients function. This specific data of women were reached. Sixty-seven women and 69 men were compared. The complex regional pain syndrome was significantly more common in women and the correction of the proximal interphalangeal joint was significantly lower in women. Recurrence rate and mean follow up were not statistically different. Mean DASH score was higher in women. We have not found any association between menopausis, pregnancy and the average age at presentation of the disease, the recurrence rate or the extension rate. The prognosis of the Dupuytren's disease is worse in women than in men. Other studies are necessary to reach the link between the testosterone and the clinical history of the disease in women. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  5. Evaluation of outcome measures for use in clinical practice for adults with musculoskeletal conditions of the knee: a systematic review.

    Science.gov (United States)

    Howe, Tracey E; Dawson, Lesley J; Syme, Grant; Duncan, Louise; Reid, Judith

    2012-04-01

    This systematic review reported on the clinimetric properties of outcome measures for use in clinical practice for adults with musculoskeletal conditions of the knee. A systematic search was performed in Medline, EMBASE, Cinahl and AMED to identify studies examining the clinimetric properties of outcome measures for adults undergoing conservative treatment of ligament injuries, meniscal lesions, patellofemoral pain and osteoarthritis of the knee. Outcomes measures taking less than 20 min to administer and requiring minimal equipment and space were included. Pairs of authors used a checklist to record the characteristics of the outcome measures, their reported clinimetric properties and the demographics of the study populations. The OMERACT filters of 'truth' and 'discrimination' were applied to the data for each outcome measure by an expert panel. Forty-seven studies were included evaluating 37 outcome measures. Ten outcome measures had adequate supporting evidence for 'truth' and 'discrimination': AAOS, AKPS, goniometer measurement, IKDC, KOOS, LEFS, Lysholm, Tegner, WOMAC and WOMET. However none of the outcome measures had been comprehensively tested across all clinimetric properties. Despite the widespread use of some outcome measures in clinical practice and primary research, data on the clinimetric properties were available for only 37 and of these only 10 had adequate supporting evidence for use in this population. However, before a core set of outcome measures can be recommended use in clinical practice, for adults with musculoskeletal conditions of the knee, consensus should be obtained on 'feasibility' in terms of burden on the clinician and the participant. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. The Effect of Yoga on Arm Volume, Strength, and Range of Motion in Women at Risk for Breast Cancer-Related Lymphedema.

    Science.gov (United States)

    Mazor, Melissa; Lee, Jeannette Q; Peled, Anne; Zerzan, Sarah; Irwin, Chetan; Chesney, Margaret A; Serrurier, Katherine; Sbitany, Hani; Dhruva, Anand; Sacks, Devorah; Smoot, Betty

    2018-02-01

    To assess the feasibility, safety, and initial estimates of efficacy of a yoga program in postoperative care for women at high risk for breast cancer-related lymphedema (BCRL). Single-group pretest-post-test design. Patients were recruited from the University of California, San Francisco Carol Franc Buck Breast Care Center. Twenty-one women were enrolled in the study. Women were >18 years of age, had undergone surgical treatment for breast cancer, and were at high risk for BCRL. The women participated in an Ashtanga yoga intervention for 8 weeks. Sessions consisted of once/week instructor-led practice and once/week home practice. Particular attention was given to poses that emphasized upper body strength and flexibility, while avoiding significant time with the upper extremity (UE) in a dependent position. UE volume was assessed through circumferential forearm measurement, which was converted to volume using the formula for a truncated cone. Range of motion (ROM) was assessed for the shoulders, elbows, and wrists, using a standard goniometer. UE strength was assessed for shoulder abduction, elbow flexion, wrist flexion, and grip using a dynamometer. Twenty women completed the yoga intervention, with 17 returning for final assessment. Mean age was 52 (±9.1) years and body mass index was 24.8 (±5.1) kg/m 2 . Postintervention, mean volume in the at-risk UE was slightly reduced (p = 0.397). ROM for shoulder flexion (p yoga is feasible and safe for women who are at risk for BCRL and may result in small improvements in shoulder ROM and UE strength.

  7. High resolution 3D imaging of synchrotron generated microbeams

    International Nuclear Information System (INIS)

    Gagliardi, Frank M.; Cornelius, Iwan; Blencowe, Anton; Franich, Rick D.; Geso, Moshi

    2015-01-01

    Purpose: Microbeam radiation therapy (MRT) techniques are under investigation at synchrotrons worldwide. Favourable outcomes from animal and cell culture studies have proven the efficacy of MRT. The aim of MRT researchers currently is to progress to human clinical trials in the near future. The purpose of this study was to demonstrate the high resolution and 3D imaging of synchrotron generated microbeams in PRESAGE® dosimeters using laser fluorescence confocal microscopy. Methods: Water equivalent PRESAGE® dosimeters were fabricated and irradiated with microbeams on the Imaging and Medical Beamline at the Australian Synchrotron. Microbeam arrays comprised of microbeams 25–50 μm wide with 200 or 400 μm peak-to-peak spacing were delivered as single, cross-fire, multidirectional, and interspersed arrays. Imaging of the dosimeters was performed using a NIKON A1 laser fluorescence confocal microscope. Results: The spatial fractionation of the MRT beams was clearly visible in 2D and up to 9 mm in depth. Individual microbeams were easily resolved with the full width at half maximum of microbeams measured on images with resolutions of as low as 0.09 μm/pixel. Profiles obtained demonstrated the change of the peak-to-valley dose ratio for interspersed MRT microbeam arrays and subtle variations in the sample positioning by the sample stage goniometer were measured. Conclusions: Laser fluorescence confocal microscopy of MRT irradiated PRESAGE® dosimeters has been validated in this study as a high resolution imaging tool for the independent spatial and geometrical verification of MRT beam delivery

  8. Quantification of Staphylococcus aureus adhesion forces on various dental restorative materials using atomic force microscopy

    International Nuclear Information System (INIS)

    Merghni, Abderrahmen; Kammoun, Dorra; Hentati, Hajer; Janel, Sébastien; Popoff, Michka; Lafont, Frank; Aouni, Mahjoub; Mastouri, Maha

    2016-01-01

    Highlights: • 4 dental restorative materials were characterized for roughness, angle contact water and surface free energy. • AFM adhesion forces of S. aureus to tested materials were achieved in presence and absence of salivary conditioning film. • S. aureus initial adhesion is dependent on the surface free energy and roughness. - Abstract: In the oral cavity dental restorative biomaterials can act as a reservoir for infection with opportunistic Staphylococcus aureus pathogen, which can lead to the occurrence of secondary caries and treatment failures. Our aim was to evaluate the adhesion forces by S. aureus on four dental restorative biomaterials and to correlate this finding to differences in specific surface characteristics. Additionally, the influence of salivary conditioning films in exerted adhesion forces was investigated. The substrate hydrophobicity was measured by goniometer and the surface free energy was calculated using the equilibrium advancing contact angle values of water, formamide, and diiodomethane on the tested surfaces. The surface roughness was determined using atomic force microscope (AFM). Additionally, cell force spectroscopy was achieved to quantify the forces that drive cell-substrate interactions. S. aureus bacterium exerted a considerable adhesion forces on various dental restorative materials, which decreased in the presence of saliva conditioning film. The influence of the surface roughness and free energy in initial adhesion appears to be more important than the effect of hydrophobicity, either in presence or absence of saliva coating. Hence, control of surface properties of dental restorative biomaterials is of crucial importance in preventing the attachment and subsequent the biofilm formation.

  9. Texture, residual stress and structural analysis of thin films using a combined X-ray analysis

    International Nuclear Information System (INIS)

    Lutterotti, L.; Chateigner, D.; Ferrari, S.; Ricote, J.

    2004-01-01

    Advanced thin films for today's industrial and research needs require highly specialized methodologies for a successful quantitative characterization. In particular, in the case of multilayer and/or unknown phases a global approach is necessary to obtain some or all the required information. A full approach has been developed integrating novel texture and residual stress methodologies with the Rietveld method (Acta Cryst. 22 (1967) 151) (for crystal structure analysis) and it has been coupled with the reflectivity analysis. The complete analysis can be done at once and offers several benefits: the thicknesses obtained from reflectivity can be used to correct the diffraction spectra, the phase analysis help to identify the layers and to determine the electron density profile for reflectivity; quantitative texture is needed for quantitative phase and residual stress analyses; crystal structure determination benefits of the previous. To achieve this result, it was necessary to develop some new methods, especially for texture and residual stresses. So it was possible to integrate them in the Rietveld, full profile fitting of the patterns. The measurement of these spectra required a special reflectometer/diffractometer that combines a thin parallel beam (for reflectivity) and a texture/stress goniometer with a curved large position sensitive detector. This new diffraction/reflectivity X-ray machine has been used to test the combined approach. Several spectra and the reflectivity patterns have been collected at different tilting angles and processed at once by the special software incorporating the aforementioned methodologies. Some analysis examples will be given to show the possibilities offered by the method

  10. Manual therapy in the treatment of patients with hemophilia B and inhibitor.

    Science.gov (United States)

    Cuesta-Barriuso, Rubén; Trelles-Martínez, Roberto O

    2018-01-22

    The main clinical manifestations of hemophilia are muscle and joint bleeding. Recurrent bleeding leads to a degenerative process known as hemophilic arthropathy. The development of inhibitors (antibodies against FVIII/FIX concentrates) is the main complication in the treatment of hemophilia. The objective was to assess the safety and efficacy of manual therapy treatment in a patient with hemophilia and inhibitor. A 26-year-old patient with hemophilia B and inhibitor received physiotherapy treatment based on manual therapy for 3 months, with a frequency of 2 sessions per week. The joint status was evaluated using the Hemophilia Joint Health Score; pain was assessed with the Visual Analog Scale; and the range of movement was evaluated using a universal goniometer. The patient developed no joint bleeding in the knees or ankles as a result of the physiotherapy treatment. Following treatment, improvements were noted in the range of movement of knees and ankles, the perception of pain in both knees, and ankle functionality. Until now, manual therapy using joint traction was contraindicated in patients with hemophilia and inhibitor, as it was feared to cause possible joint bleeding. This is the first case study to address the safety and efficacy of manual therapy in a patient with hemophilia and an inhibitor. The results of this study may help to establish which manual therapy treatments are indicated in patients with hemophilic arthropathy and inhibitors. Thus, a physiotherapy program based on manual therapy may be safe in patients with hemophilia and inhibitor and such therapy may improve joint condition, pain, and joint range of motion in patients with hemophilia and inhibitor. Randomized clinical trials are needed to confirm the results of this case study.

  11. IMMEDIATE EFFECT OF CERVICAL MANIPULATION ON PAIN AND RANGE OF MOTION IN PATIENTS WITH CHRONIC MECHANICAL NECK PAIN

    Directory of Open Access Journals (Sweden)

    Kabir Isah Mayana

    2017-06-01

    Full Text Available Background: Neck pain has been reported as a prevalent musculoskeletal disorder globally with more than half of the general population being affected once or more within their life span. Methods: A randomized clinical trial research design was used which investigated the immediate effect of cervical manipulation on neck pain and cervical range of motion among patients with chronic mechanical neck pain. 20 male and female participants between the ages of 26 to 60 years with chronic mechanical neck pain attending physiotherapy clinics were recruited. They were randomly assigned into two groups (A and B of 10 patients each. Group A received soft tissue massage, and cervical manipulation and group B served as the control group, and they received only soft tissue massage. There were two outcomes measured; Pain intensity was rated using visual analog scale (VAS before and immediately after the intervention. Pre and Post intervention measurements of cervical spine range of motion using Goniometer were also taken. Results: Findings of the study revealed significant immediate improvement of pain and Cervical Range of Motions (p<0.05 in all dimensions in the experimental group while Pain, flexion and right side Cervical flexion significantly improved in the control group. It was also found out after comparing the outcomes between the two groups that, the experimental group had significantly (p<0.05 better improvement than the control group in post-intervention pain, cervical flexion, cervical extension and cervical (right and left lateral rotations. Conclusion: Cervical manipulation is effective in immediate pain relief and improvement in cervical range of motion in patients with mechanical neck pain

  12. Integrated microfluidic probe station.

    Science.gov (United States)

    Perrault, C M; Qasaimeh, M A; Brastaviceanu, T; Anderson, K; Kabakibo, Y; Juncker, D

    2010-11-01

    The microfluidic probe (MFP) consists of a flat, blunt tip with two apertures for the injection and reaspiration of a microjet into a solution--thus hydrodynamically confining the microjet--and is operated atop an inverted microscope that enables live imaging. By scanning across a surface, the microjet can be used for surface processing with the capability of both depositing and removing material; as it operates under immersed conditions, sensitive biological materials and living cells can be processed. During scanning, the MFP is kept immobile and centered over the objective of the inverted microscope, a few micrometers above a substrate that is displaced by moving the microscope stage and that is flushed continuously with the microjet. For consistent and reproducible surface processing, the gap between the MFP and the substrate, the MFP's alignment, the scanning speed, the injection and aspiration flow rates, and the image capture need all to be controlled and synchronized. Here, we present an automated MFP station that integrates all of these functionalities and automates the key operational parameters. A custom software program is used to control an independent motorized Z stage for adjusting the gap, a motorized microscope stage for scanning the substrate, up to 16 syringe pumps for injecting and aspirating fluids, and an inverted fluorescence microscope equipped with a charge-coupled device camera. The parallelism between the MFP and the substrate is adjusted using manual goniometer at the beginning of the experiment. The alignment of the injection and aspiration apertures along the scanning axis is performed using a newly designed MFP screw holder. We illustrate the integrated MFP station by the programmed, automated patterning of fluorescently labeled biotin on a streptavidin-coated surface.

  13. What is the Optimal Treatment of Atrophic Scaphoid Non-Union?

    Directory of Open Access Journals (Sweden)

    Alper Cirakli

    2016-09-01

    Full Text Available Aim: To evaluate the efficacy of the treatment method of autogenous iliac wing or radius bone graft and fixation with screw applied to cases of scaphoid non-union. Material and Method: A retrospective evaluation was made of 89 cases between 2000 and 2014. Postoperative measurements were taken of both wrists%u2019 movement with a goniometer and muscle strength was assessed with a dynamometer. Fractures were evaluated radiologically according to the Herbert-Fisher System and the functional results according to the Herbert-Fisher Classification System and the Mayo Clinic Modified Wrist Scoring System. The data were input to the SPSS system and evaluated with the Shapiro-Wilk test. Results: Non-union were on the right side in 47 and the left side in 42 cases. The fracture was seen to be in the waist in 60 cases (67.5%, in the proximal third in 27 cases (30.3% and in the distal third in two cases (2.2%. The mean follow-up period was 16.4 months (range, 5-72 months. Definitive findings of union were observed in 71 cases. The mean time to union was 14.9 weeks (range, 8-40 weeks. Discussion: The grafting procedure applied is an invasive technique but if it is considered that there are negative effects of open surgery on the feeding of the scaphoid bone, then in the treatment of scaphoid non-union which is atrophic non-union, ultimately autogenous bone grafting and screw fixation is a safe and successful method and because of the pain created by an iliac wing graft, radius distal bone graft can be considered more appropriate.

  14. Regular Aerobic Training Combined with Range of Motion Exercises in Juvenile Idiopathic Arthritis

    Directory of Open Access Journals (Sweden)

    Mine Doğru Apti

    2014-01-01

    Full Text Available Objective. To assess the effects of regular aerobic training combined with range of motion (ROM exercises on aerobic capacity, quality of life, and function in children with juvenile idiopathic arthritis (JIA. Methods. Thirty patients with JIA and 20 healthy age-matched controls (mean age ± SD, 11.3 ± 2.4 versus 11.0 ± 2.3, resp.; P>0.05 were included. All patients performed aerobic walking (4 days a week for 8 weeks and active and passive ROM exercises of involved joints. All patients completed the childhood health assessment questionnaire (CHAQ and the child health questionnaire. ROM measurements of joints were performed by using universal goniometer. Aerobic capacity was determined by measuring peak oxygen uptake (VO2peak during an incremental treadmill test. Results. Peak oxygen uptake and exercise duration were significantly lower in JIA group than in controls (32.5 ± 6.6 versus 35.9 ± 5.8 and 13.9 ± 1.9 versus 15.0 ± 2.0, resp.; P<0.05 for both. Eight-week combined exercise program significantly improved exercise parameters of JIA patients (baseline versus postexercise VO2peak and exercise duration, 32.5 ± 6.6 to 35.3 ± 7.9 and 13.9 ± 1.9 to 16.3 ± 2.2, resp.; P<0.001 for both. Exercise intervention significantly improved CHAQ scores in JIA patients (0.77 ± 0.61 to 0.20 ± 0.28, P<0.001. Conclusion. We suggest that regular aerobic exercise combined with ROM exercises may be an important part of treatment in patients with JIA.

  15. Relationship of orthopedic examination, goniometric measurements, and radiographic signs of degenerative joint disease in cats.

    Science.gov (United States)

    Lascelles, B Duncan X; Dong, Yaa-Hui; Marcellin-Little, Denis J; Thomson, Andrea; Wheeler, Simon; Correa, Maria

    2012-01-27

    Available information suggests a mismatch between radiographic and orthopedic examination findings in cats with DJD. However, the extent of the discrepancy between clinical and radiographic signs of OA in companion animals has not been described in detail. This study aimed to evaluate the relationship between orthopedic examination findings, joint goniometry, and radiographic signs of DJD in 100 cats, in a prospective observational design. Cat temperament, pain response to palpation, joint crepitus, effusion and thickening were graded. Radiographs of appendicular joints and the axial skeleton were made under sedation. Joint motion was measured by use of a plastic goniometer before and after sedation. Associations between radiographic degenerative joint disease (DJD) and examination findings were assessed to determine sensitivity, specificity and likelihood estimations. Pain response to palpation was elicited in 0-67% of the joints with DJD, with a specificity ranging from 62-99%; crepitus was detected in 0-56% of the joints and its specificity varied between 87 and 99%; for effusion, values ranged between 6 and 38% (specificity, 82-100%), and thickening, 0-59% (specificity, 74-99%). Joints with DJD tended to have a decreased range of motion. The presence of pain increased the odds of having DJD in the elbow (right: 5.5; left: 4.5); the presence of pain in the lower back increased the odds of spinal DJD being present (2.97 for lumbar; 4.67 for lumbo-sacral). Radiographic DJD cannot be diagnosed with certainty using palpation or goniometry. However, negative findings tend to predict radiographically normal joints. Palpation and goniometry may be used as a tool to help to screen cats, mostly to rule out DJD.

  16. Relationship of orthopedic examination, goniometric measurements, and radiographic signs of degenerative joint disease in cats

    Directory of Open Access Journals (Sweden)

    Lascelles B Duncan X

    2012-01-01

    Full Text Available Abstract Background Available information suggests a mismatch between radiographic and orthopedic examination findings in cats with DJD. However, the extent of the discrepancy between clinical and radiographic signs of OA in companion animals has not been described in detail. This study aimed to evaluate the relationship between orthopedic examination findings, joint goniometry, and radiographic signs of DJD in 100 cats, in a prospective observational design. Cat temperament, pain response to palpation, joint crepitus, effusion and thickening were graded. Radiographs of appendicular joints and the axial skeleton were made under sedation. Joint motion was measured by use of a plastic goniometer before and after sedation. Associations between radiographic degenerative joint disease (DJD and examination findings were assessed to determine sensitivity, specificity and likelihood estimations. Results Pain response to palpation was elicited in 0-67% of the joints with DJD, with a specificity ranging from 62-99%; crepitus was detected in 0-56% of the joints and its specificity varied between 87 and 99%; for effusion, values ranged between 6 and 38% (specificity, 82-100%, and thickening, 0-59% (specificity, 74-99%. Joints with DJD tended to have a decreased range of motion. The presence of pain increased the odds of having DJD in the elbow (right: 5.5; left: 4.5; the presence of pain in the lower back increased the odds of spinal DJD being present (2.97 for lumbar; 4.67 for lumbo-sacral. Conclusions Radiographic DJD cannot be diagnosed with certainty using palpation or goniometry. However, negative findings tend to predict radiographically normal joints. Palpation and goniometry may be used as a tool to help to screen cats, mostly to rule out DJD.

  17. HIPPO, the high-pressure preferred orientation diffractometer at LANSCE for characterization of bulk materials

    International Nuclear Information System (INIS)

    Bennett, K.; Dreele, R.B. von; Wenk, H.R.

    2001-01-01

    United States National Laboratory researchers and University of California faculty, representing a broad range of scientific disciplines, is building a novel time-of-flight (TOF) neutron diffractometer and associated in situ equipment at the Manuel Lujan Jr. Neutron Scattering Center (Lujan Center), under the auspices of the United States Department of Energy. The goal with the High-Pressure Preferred Orientation Instrument (HIPPO) is to investigate dynamic processes in heterogeneous bulk materials in a variety of environments. The instrument, which will become available in summer 2001, has the extremely high count-rates necessary to study time-dependent processes in small (1-mm diameter) and large (2-cm diameter) samples, and in a large variety of environmental conditions (10-2000 K cryostats and furnaces, 0-20 GPa pressure vessels, straining cells, goniometers, magnets, etc.). The 3-D arrangement of detectors allows direct measurements of crystal orientation distributions in polycrystalline materials. The analysis of TOF diffraction patterns with versatile Rietveld codes provides simultaneous information on crystal structure, texture, microstructure and phase proportions. While this instrument has many applications in materials science, it is also of great interest for geology and geophysics. Some applications include: kinetics of reactions, structure of silicate glasses and melts, high-pressure investigations of complex systems, evolution of texture and anisotropy during deformation and recrystallization. The Lujan Center aims at creating an instrument with high data through-put and easy access to researchers and students. While the HIPPO instrument will be part of the national user facility operated by the Lujan Center, the scientific program will be guided by the University of California consortium with the goal of satisfying national priorities and establishing an environment of scientific excellence. (author)

  18. Range of motion and isometric strength of shoulder joints of team handball athletes during the playing season, Part II: changes after midseason.

    Science.gov (United States)

    Fieseler, Georg; Jungermann, Philipp; Koke, Alexander; Irlenbusch, Lars; Delank, Karl-Stefan; Schwesig, Rene

    2015-03-01

    Our objective was to investigate the influence of workload and consecutive changes on active range of motion and isometric strength of team handball athletes' throwing shoulders (TSs) because the available data are insufficient. In a longitudinal investigation, 31 professional male handball athletes underwent a clinical shoulder examination. Athletes were examined at the beginning (week 0), at the end (week 6) of the preseasonal training, and at the end of the half-season (week 22) on both shoulders to determine isometric rotational strength (hand held dynamometer) and active range of motion (goniometer). This analysis demonstrates the results subsequently from week 6 to week 22 and from week 0 to week 22. The glenohumeral internal rotation (IR) deficit (GIRD), external rotation (ER) gain, and ER at the TS increased significantly (P 0.10, d > 0.30) in the first sequence (week 6 to week 22) but not significantly from week 0 to week 22. The total range of motion remained stable, and IR changed but not significantly. There was no influence on IR, ER, and total range of motion at the non-TS. The isometric strength of the TS and non-TS IR did not change. The isometric strength in ER significantly increased bilaterally during the investigation period. Our data verify changes and influences, such as an increasing GIRD, at the overhead TS joint in accordance with the workload during team handball season. ER gain did improve after the half-season period but did not fully compensate the GIRD at the TS. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  19. IMPACT OF REFLEXOLOGY ON MECHANICAL LOW BACK PAIN

    Directory of Open Access Journals (Sweden)

    Salwa El-Gendy

    2015-10-01

    Full Text Available Background: Low-back pain (LBP is one of the highest common and costly musculoskeletal conditions in current society. Seventy to 85% of the populations will exhibits LBP at some time in their lives. There is little known about specific manual therapy techniques used to treat chronic LBP. Reflexology is a treatment that involves using gentle pressure to reflex points located on all of the outsides of the feet and hands. The aim of the study was to investigate the efficacy of reflexology technique in subjects with chronic low back pain (CLBP. Methods: Twenty patients with nonspecific chronic low back pain were included in the study and were assessed regarding range of motion via goniometer and pain threshold (via modified Oswestery scale and visual analogue scale, the 20 patients were allocated into two groups 10 patients in each group. Group A received reflexology sittings at rate of 3 days per week, and the duration of each sitting was 30 minutes. While group B were control. The study was continued for 3 weeks Results: According to VAS, the results revealed a non-significant variance between the study group and control group before intervention (p= 0.43. While after intervention, there was a significant decline of pain in the study group compared to that of the control group (p=0.000. Moreover, there was a very highly significant decrease in pain within the study group after treatment (p= 0.005. Conclusion: The present study indicated that the reflexology technique was effective and safe to be applied for cases of mechanical low back pain. It results in a significant decrease in pain within the study group after treatment.

  20. [Do children with attention deficit and hyperactivity disorder (ADHD) have a diferent gait pattern? Relationship between idiopathic toe-walking and ADHD].

    Science.gov (United States)

    Soto Insuga, Víctor; Moreno Vinués, Beatriz; Losada Del Pozo, Rebeca; Rodrigo Moreno, María; Martínez González, Marta; Cutillas Ruiz, Raquel; Mateos Carmen, Carmen

    2018-04-01

    Idiopathic toe-walking (ITW) is described as a gait pattern with no contact between the heels and the ground in children older than 3years. The diagnosis is clinical, making it necessary to rule out other neurological and orthopaedic conditions. A relationship between ITW and vestibular dysfunction and/or proprioceptive sensibility has been proposed. Children with neurodevelopmental disorders (autism, language and cognitive disorders) often have ITW. To determine the frequency of ITW in children with attention deficit disorder and hyperactivity (ADHD). A study was conducted on children diagnosed with ADHD, with normal neurological examination, with no alterations in MRI scan, cognitive disorder or autism. A complete clinical anamnesis was performed and Achilles shortening was measured with a goniometer. The study included 312 children with a mean age of 11 years (73.7% boys). The ADHD combined subtype was the most frequent (53.8%), followed by the inattentive (44.9%), and hyperactive (1.3%). ITW was observed in 20.8% of patients, particularly in the combined subtype (P=.054). Only 32 of them (49.2%) had Achilles shortening. ITW was associated with sociability disorders (P=.01), absence of pain in legs (P=.022), and family history of ITW (P=.004). Only 11% had previously visited a doctor for this reason. As in other neurodevelopmental disorders, children with ADHD have frequently more ITW and Achilles shortening than controls, especially if they presented with a social communication disorder or a family history of ITW. An early diagnosis is essential to establish effective treatments. Copyright © 2016 Asociación Española de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. Temperature-monitored optical treatment for radial tissue expansion.

    Science.gov (United States)

    Bak, Jinoh; Kang, Hyun Wook

    2017-07-01

    Esophageal stricture occurs in 7-23% of patients with gastroesophageal reflux disease. However, the current treatments including stent therapy, balloon dilation, and bougienage involve limitations such as stent migration, formation of the new strictures, and snowplow effect. The purpose of the current study was to investigate the feasibility of structural expansion in tubular tissue ex vivo during temperature-monitored photothermal treatment with a diffusing applicator for esophageal stricture. Porcine liver was used as an ex vivo tissue sample for the current study. A glass tube was used to maintain a constant distance between the diffuser and tissue surface and to evaluate any variations in the luminal area after 10-W 1470-nm laser irradiation for potential stricture treatment. The 3D goniometer measurements confirmed roughly isotropic distribution with less than 10% deviation from the average angular intensity over 2π (i.e., 0.86 ± 0.09 in arbitrary unit) from the diffusing applicator. The 30-s irradiation increased the tissue temperature up to 72.5 °C, but due to temperature feedback, the interstitial tissue temperature became saturated at 70 °C (i.e., steady-state error = ±0.4 °C). The irradiation times longer than 5 s presented area expansion index of 1.00 ± 0.04, signifying that irreversible tissue denaturation permanently deformed the lumen in a circular shape and secured the equivalent luminal area to that of the glass tube. Application of a temperature feedback controller for photothermal treatment with the diffusing applicator can regulate the degree of thermal denaturation to feasibly treat esophageal stricture in a tubular tissue.

  2. Effects of Therapeutic Exercises on Functional Capacities of Patient with Rheumatoid Arthritis

    Directory of Open Access Journals (Sweden)

    E Haji Zadeh

    2002-09-01

    Full Text Available Introduction: Rheumatoid arthritis (RA is a chronic and systemic inflammatory disease of unknown etiology. It is characterized by symmetric joint involvement with progressive deformities. This leads to limitation of motion and reduction of activity daily living (ADL. Previous reports showed the beneficial effects of therapeutic exercises in these patients in the remission phase. Methods and Materials: A clinical trial as a self-control sequential control study was designed to determine the effectiveness of a range of motion (ROM exercise program in patients with RA, referring to Rheumatology Research Center between 1994-1995. ROM of the selected joints by Goniometer, and ADL by a questionnaire was assessed in all patients in 3 phases: when entering the program, after 6 weeks of observation, and then after another 6 weeks with the therapeutic exercises. The mean difference in these 2 period were compared by student paired t test. The analysis of differences between different subgroups (job, education, etc. was done by one way variance analysis. Results: Forty patients completed the program. The mean ADL increased from 0437±0.252 before exercise to 6.69±3.06 after exercise (P<0.001, and the mean scores of ROM increased from 0.278±0.28 to 8±3.57 (P<0.0001, both statistically significant. This was more pronounced in women and in those with ankle joints involvement. The type of disease onset and duration of the disease did not influence the effects of treatment. No increase in disease activity was seen. Conclusion: This study showed the effectiveness of our ROM exercises in increasing functional capacities of patients with RA in remission phase.

  3. Effect of yoga on quality of life of CLBP patients: A randomized control study

    Directory of Open Access Journals (Sweden)

    Tekur Padmini

    2010-01-01

    Full Text Available Context: In two of the earlier Randomized Control Trials on yoga for chronic lower back pain (CLBP, 12 to 16 weeks of intervention were found effective in reducing pain and disability. Aim: To study the efficacy of a residential short term intensive yoga program on quality of life in CLBP. Materials and Methods: About 80 patients with CLBP (females 37 registered for a week long treatment at SVYASA Holistic Health Centre in Bengaluru, India. They were randomized into two groups (40 each. The yoga group practiced a specific module for CLBP comprising of asanas (physical postures, pranayama (breathing practices, meditation and lectures on yoga philosophy. The control group practiced physical therapy exercises for back pain. Perceived stress scale (PSS was used to measure baseline stress levels. Outcome measures were WHOQOL Bref for quality of life and straight leg raising test (SLR using a Goniometer. Results: There were significant negative correlations (Pearson′s, P<0.005, r>0.30 between baseline PSS with all four domains and the total score of WHOQOLBref. All the four domains′ WHOQOLBref improved in the yoga group (repeated measures ANOVA P=0.001 with significant groupFNx01time interaction (P<0.05 and differences between groups (P<0.01. SLR increased in both groups (P=0.001 with higher increase in yoga (31.1 % right, 28.4 % left than control (18.7% right, 21.5 % left group with significant groupFNx01time interaction (SLR right leg P=0.044. Conclusion: In CLBP, a negative correlation exists between stress and quality of life. Yoga increases quality of life and spinal flexibility better than physical therapy exercises.

  4. Biomechanical implications of walking with indigenous footwear.

    Science.gov (United States)

    Willems, Catherine; Stassijns, Gaetane; Cornelis, Wim; D'Août, Kristiaan

    2017-04-01

    This study investigates biomechanical implications of walking with indigenous "Kolhapuri" footwear compared to barefoot walking among a population of South Indians. Ten healthy adults from South India walked barefoot and indigenously shod at voluntary speed on an artificial substrate. The experiment was repeated outside, on a natural substrate. Data were collected from (1) a heel-mounted 3D-accelerometer recording peak impact at heel contact, (2) an ankle-mounted 3D-goniometer (plantar/dorsiflexion and inversion/eversion), and (3) sEMG electrodes at the m. tibialis anterior and the m. gastrocnemius medialis. Data show that the effect of indigenous footwear on the measured variables, compared to barefoot walking, is relatively small and consistent between substrates (even though subjects walked faster on the natural substrate). Walking barefoot, compared to shod walking yields higher impact accelerations, but the differences are small and only significant for the artificial substrate. The main rotations of the ankle joint are mostly similar between conditions. Only the shod condition shows a faster ankle rotation over the rapid eversion motion on the natural substrate. Maximal dorsiflexion in late stance differs between the footwear conditions on an artificial substrate, with the shod condition involving a less dorsiflexed ankle, and the plantar flexion at toe-off is more extreme when shod. Overall the activity pattern of the external foot muscles is similar. The indigenous footwear studied (Kolhapuri) seems to alter foot biomechanics only in a subtle way. While offering some degree of protection, walking in this type of footwear resembles barefoot gait and this type of indigenous footwear might be considered "minimal". © 2017 The Authors American Journal of Physical Anthropology Published by Wiley Periodicals, Inc.

  5. The Effect of Single Portion Glutamine Supplement Consumption on Injury Indices of Muscle After Eccentric Resistance Exercise

    Directory of Open Access Journals (Sweden)

    Azadeh Najarzadeh

    2015-07-01

    Full Text Available Abstract Background: Delayed muscular soreness after resistance exercises or eccentric trainings is probably because of muscle damage and injury. Nutrition by playing a crucial role in both protein synthesize and catabolism can influence the extent of muscle injury. The objective of this study was to assess the effect of single portion of Glutamine supplement consumption on injury indices of muscle after a session eccentric resistance exercise. Materials and Methods: this study used a randomized, double blind design that consisted of 80 volvnteer non-athletic males (aged 22.2±2.2years, height 175±5 cm, weight 71/64±9 kg, body mass index 23/2±2/2 kg/m2, and body fat 17/5±2/4%. A total of 40 participants were divided randomly into 2 groups, supplement group (receiving 0/1 g/kg Body weight/ day Glutamine and placebo group (receiving 0/1 g/kg Body weight/ day Maltodextrin. Serum keratine kinase (CK was determined by photometric method, muscle pain and knee joint range of motion were measured using, respectively, a standard scale of PAS and goniometer before, 24 and 48 hours after a resistance test involving knee flexion. Results: Glutamine supplement consumption caused no significant differences in CK levels reduction in none of the measured times, but it reduced the muscle pain at the times of 24 and 48 hours in comparison with the placebo group. In addition, the knee joint range of motion was significantly improved at 24 hours after the test. Conclusion: It seems that this dose of Glutamine supplementation can reduce the apparent signs apart from muscle injury indices reduction.

  6. HIPPO, the high-pressure preferred orientation diffractometer at LANSCE for characterization of bulk materials

    Energy Technology Data Exchange (ETDEWEB)

    Bennett, K.; Dreele, R.B. von [Manuel Lujan Jr. Neutron Scattering Center, Los Alamos, NM (United States); Wenk, H.R. [Department of Geology and Geophysics, Univ. of California, Berkely, CA (United States)

    2001-03-01

    United States National Laboratory researchers and University of California faculty, representing a broad range of scientific disciplines, is building a novel time-of-flight (TOF) neutron diffractometer and associated in situ equipment at the Manuel Lujan Jr. Neutron Scattering Center (Lujan Center), under the auspices of the United States Department of Energy. The goal with the High-Pressure Preferred Orientation Instrument (HIPPO) is to investigate dynamic processes in heterogeneous bulk materials in a variety of environments. The instrument, which will become available in summer 2001, has the extremely high count-rates necessary to study time-dependent processes in small (1-mm diameter) and large (2-cm diameter) samples, and in a large variety of environmental conditions (10-2000 K cryostats and furnaces, 0-20 GPa pressure vessels, straining cells, goniometers, magnets, etc.). The 3-D arrangement of detectors allows direct measurements of crystal orientation distributions in polycrystalline materials. The analysis of TOF diffraction patterns with versatile Rietveld codes provides simultaneous information on crystal structure, texture, microstructure and phase proportions. While this instrument has many applications in materials science, it is also of great interest for geology and geophysics. Some applications include: kinetics of reactions, structure of silicate glasses and melts, high-pressure investigations of complex systems, evolution of texture and anisotropy during deformation and recrystallization. The Lujan Center aims at creating an instrument with high data through-put and easy access to researchers and students. While the HIPPO instrument will be part of the national user facility operated by the Lujan Center, the scientific program will be guided by the University of California consortium with the goal of satisfying national priorities and establishing an environment of scientific excellence. (author)

  7. Análise da variação dos valores da rotação medial conforme a posição da diáfise do úmero Analysis on the variation of medial rotation values according to the position of the humeral diaphysis

    Directory of Open Access Journals (Sweden)

    Alberto Naoki Miyazaki

    2012-01-01

    Full Text Available OBJETIVO: Analisar a validade da medida de rotação medial (RM do ombro pelos níveis vertebrais conforme a variação da posição da diáfise do úmero, testando o bigoniômetro como novo instrumental de aferição. MÉTODOS: Foram avaliados, prospectivamente, 140 ombros (70 pacientes que tinham limitação da RM do ombro unilateral. Avaliou-se, por meio da escala visual, o nível vertebral e correlacionou-se com o ângulo obtido conforme a posição da diáfise do úmero utilizando o bigoniômetro desenvolvido com a Engenharia Mecânica do Mackenzie. RESULTADOS: O nível vertebral máximo alcançado na RM do lado não acometido variou de T3 a T12, e para o lado acometido variou de T6 a trocânter. Já quando o membro acometido foi reposicionado em RM de acordo com os valores angulares do lado normal, 57,13% dos pacientes alcançaram níveis mais baixos entre sacro, glúteo e trocânter. Analisando o nível vertebral máximo alcançado e a variação entre o ângulo x (plano frontal: abdução e RM do ombro acometido e o ângulo x não acometido em RM, verificamos que quanto maior a angulação do eixo da diáfise menor a variação do nível vertebral alcançado. Avaliando a correlação linear entre as variáveis diferença do nível vertebral máximo alcançado e a variação do ângulo y (extensão e adução do ombro acometido e ângulo y não acometido em RM, verificamos que não há uma relação linear bem estabelecida entre estas variáveis. CONCLUSÃO: A medida da RM pelos níveis vertebrais não corresponde aos valores reais, pois varia conforme o posicionamento da diáfise do úmero.OBJECTIVE: To analyze the validity of measurements of shoulder medial rotation (MR of the shoulder, using vertebral levels, according to the variation in the position of the humeral diaphysis, and to test the bi-goniometer as a new measuring instrument. METHODS: 140 shoulders (70 patients were prospectively evaluated in cases presenting unilateral

  8. a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    MS Yıldırım

    2016-02-01

    Full Text Available The aim of this study was to compare the effects of static stretching, proprioceptive neuromuscular facilitation (PNF stretching and Mulligan technique on hip flexion range of motion (ROM in subjects with bilateral hamstring tightness. A total of 40 students (mean age: 21.5±1.3 years, mean body height: 172.8±8.2 cm, mean body mass index: 21.9±3.0 kg • m-2 with bilateral hamstring tightness were enrolled in this randomized trial, of whom 26 completed the study. Subjects were divided into 4 groups performing (I typical static stretching, (II PNF stretching, (III Mulligan traction straight leg raise (TSLR technique, (IV no intervention. Hip flexion ROM was measured using a digital goniometer with the passive straight leg raise test before and after 4 weeks by two physiotherapists blinded to the groups. 52 extremities of 26 subjects were analyzed. Hip flexion ROM increased in all three intervention groups (p<0.05 but not in the no-intervention group after 4 weeks. A statistically significant change in initial–final assessment differences of hip flexion ROM was found between groups (p<0.001 in favour of PNF stretching and Mulligan TSLR technique in comparison to typical static stretching (p=0.016 and p=0.02, respectively. No significant difference was found between Mulligan TSLR technique and PNF stretching (p=0.920. The initial–final assessment difference of hip flexion ROM was similar in typical static stretching and no intervention (p=0.491. A 4-week stretching intervention is beneficial for increasing hip flexion ROM in bilateral hamstring tightness. However, PNF stretching and Mulligan TSLR technique are superior to typical static stretching. These two interventions can be alternatively used for stretching in hamstring tightness.

  9. Long-term outcomes five years after selective dorsal rhizotomy

    Directory of Open Access Journals (Sweden)

    Lagergren Jan

    2008-12-01

    Full Text Available Abstract Background Selective dorsal rhizotomy (SDR is a well accepted neurosurgical procedure performed for the relief of spasticity interfering with motor function in children with spastic cerebral palsy (CP. The goal is to improve function, but long-term outcome studies are rare. The aims of this study were to evaluate long-term functional outcomes, safety and side effects during five postoperative years in all children with diplegia undergoing SDR combined with physiotherapy. Methods This study group consisted of 35 children, consecutively operated, with spastic diplegia, of which 26 were Gross Motor Function Classification System (GMFCS levels III–V. Mean age was 4.5 years (range 2.5–6.6. They were all assessed by the same multidisciplinary team at pre- and at 6, 12, 18 months, 3 and 5 years postoperatively. Clinical and demographic data, complications and number of rootlets cut were prospectively registered. Deep tendon reflexes and muscle tone were examined, the latter graded with the modified Ashworth scale. Passive range of motion (PROM was measured with a goniometer. Motor function was classified according to the GMFCS and measured with the Gross Motor Function Measure (GMFM-88 and derived into GMFM-66. Parent's opinions about the children's performance of skills and activities and the amount of caregiver assistance were measured with Pediatric Evaluation Disability Inventory (PEDI. Results The mean proportion of rootlets cut in S2-L2 was 40%. Muscle tone was immediately reduced in adductors, hamstrings and dorsiflexors (p Conclusion SDR is a safe and effective method for reducing spasticity permanently without major negative side effects. In combination with physiotherapy, in a group of carefully selected and systematically followed young children with spastic diplegia, it provides lasting functional benefits over a period of at least five years postoperatively.

  10. Magnetosome chain superstructure in uncultured magnetotactic bacteria

    International Nuclear Information System (INIS)

    Abraçado, Leida G; Farina, Marcos; Abreu, Fernanda; Keim, Carolina N; Lins, Ulysses; Campos, Andrea P C

    2010-01-01

    Magnetotactic bacteria produce magnetosomes, which are magnetic particles enveloped by biological membranes, in a highly controlled mineralization process. Magnetosomes are used to navigate in magnetic fields by a phenomenon called magnetotaxis. Two levels of organization and control are recognized in magnetosomes. First, magnetotactic bacteria create a spatially distinct environment within vesicles defined by their membranes. In the vesicles, the bacteria control the size, composition and purity of the mineral content of the magnetic particles. Unique crystal morphologies are produced in magnetosomes as a consequence of this bacterial control. Second, magnetotactic bacteria organize the magnetosomes in chains within the cell body. It has been shown in a particular case that the chains are positioned within the cell body in specific locations defined by filamentous cytoskeleton elements. Here, we describe an additional level of organization of the magnetosome chains in uncultured magnetotactic cocci found in marine and freshwater sediments. Electron microscopy analysis of the magnetosome chains using a goniometer showed that the magnetic crystals in both types of bacteria are not oriented at random along the crystal chain. Instead, the magnetosomes have specific orientations relative to the other magnetosomes in the chain. Each crystal is rotated either 60°, 180° or 300° relative to their neighbors along the chain axis, causing the overlapping of the (1 1 1) and (1-bar 1-bar 1-bar) capping faces of neighboring crystals. We suggest that genetic determinants that are not present or active in bacteria with magnetosomes randomly rotated within a chain must be present in bacteria that organize magnetosomes so precisely. This particular organization may also be used as an indicative biosignature of magnetosomes in the study of magnetofossils in the cases where this symmetry is observed

  11. Processing method for high resolution monochromator

    International Nuclear Information System (INIS)

    Kiriyama, Koji; Mitsui, Takaya

    2006-12-01

    A processing method for high resolution monochromator (HRM) has been developed at Japanese Atomic Energy Agency/Quantum Beam Science Directorate/Synchrotron Radiation Research unit at SPring-8. For manufacturing a HRM, a sophisticated slicing machine and X-ray diffractometer have been installed for shaping a crystal ingot and orienting precisely the surface of a crystal ingot, respectively. The specification of the slicing machine is following; Maximum size of a diamond blade is φ 350mm in diameter, φ 38.1mm in the spindle diameter, and 2mm in thickness. A large crystal such as an ingot with 100mm in diameter, 200mm in length can be cut. Thin crystal samples such as a wafer can be also cut using by another sample holder. Working distance of a main shaft with the direction perpendicular to working table in the machine is 350mm at maximum. Smallest resolution of the main shaft with directions of front-and-back and top-and-bottom are 0.001mm read by a digital encoder. 2mm/min can set for cutting samples in the forward direction. For orienting crystal faces relative to the blade direction adjustment, a one-circle goniometer and 2-circle segment are equipped on the working table in the machine. A rotation and a tilt of the stage can be done by manual operation. Digital encoder in a turn stage is furnished and has angle resolution of less than 0.01 degrees. In addition, a hand drill as a supporting device for detailed processing of crystal is prepared. Then, an ideal crystal face can be cut from crystal samples within an accuracy of about 0.01 degrees. By installation of these devices, a high energy resolution monochromator crystal for inelastic x-ray scattering and a beam collimator are got in hand and are expected to be used for nanotechnology studies. (author)

  12. Modification of polyimide wetting properties by laser ablated conical microstructures

    International Nuclear Information System (INIS)

    Least, Brandon T.; Willis, David A.

    2013-01-01

    Laser texturing of Kapton ® HN polyimide was performed by low-fluence ablation using a pulsed, frequency tripled (349 nm) Nd:YLF laser. The laser was scanned in two dimensions in order to generate texture over a large area. The laser overlap percentage and fluence were varied and the resulting texture was studied. The texture features were inspected by electron microscopy and energy dispersive X-Ray spectroscopy (EDS), while the static contact angle of de-ionized water was measured by a contact angle goniometer. Rounded bump features were formed at all fluences, which decreased in areal density with fluence and number of laser pulses. Conical microstructures or “cones” were also formed at most fluences. Cones were larger than the bumps and thus had lower areal density, which increased as a function of the number of laser pulses. The polyimide was hydrophilic before texturing, with a contact angle of approximately 76°. For most of the experimental conditions the contact angle increased as a result of texturing, with the contact angle exceeding 90° for some textured surfaces, and reaching values as high as 118°. In general, the surfaces with significant increases in contact angle had high density of texture features, either bumps or cones. The surfaces that experienced a decrease in contact angle generally had low density of texture features. The increase in contact angle from a wetting (θ 90°) cannot be explained by texturing alone. EDS measurements indicate that textured regions had higher carbon content than the untextured regions due to depletion of oxygen species. The increase in carbon content relative to the oxygen content increased the native contact angle of the surface, causing the transition from hydrophilic to hydrophobic behavior. The contact angle of a textured surface increased as the relative spacing of features (diameter to spacing) decreased.

  13. Crystallized solids characterization by X-ray diffraction

    International Nuclear Information System (INIS)

    Broll, N.

    1996-01-01

    This work deals with the crystallized solids characterization by X-ray diffraction. The powders diffraction principle is described. Then are given the different powders diffraction experimental methods. An X-ray diffraction device is essentially constituted of three parts: the X-rays source, the sample and the detector. The source is usually constituted by an X-rays tube whereas the sample can be fixed on a photographic chamber or put on a goniometer. The different photographic chambers which can be used (Debye-Scherrer, Seeman-Bohlin and Guinier) are described. The powders diffractometer the most used is a Bragg-Brentano focusing diffractometer because it allows to obtain very sharp spectral lines and an important diffracted intensity. The detectors which are the mainly used are the scintillation counters. The most important use in powders diffractometry is the identification of the different phases of a sample. The phases identification consists to compare the unknown sample spectrum at those of standard materials indexed until now. Two methods exist at present. They are explained and their limits in the phases search are given. Another use of the X-ray diffraction is the quantitative analysis. It consists to determine the concentrations of each crystal phases of a sample. The principles of these quantitative methods are given. The lattice parameters of a polycrystal material can be determined from its X-ray pattern too with a very high precision. The way to index powders patterns is given. The residual stresses of materials can also be estimated. The principle of this measured method is explained. It is at last possible to study from an X-ray pattern, the material grain orientations during the different steps of preparation and working. (O.M.). 13 refs., 19 figs., 1 tab

  14. A Prospective Study of Overuse Knee Injuries Among Female Athletes With Muscle Imbalances and Structural Abnormalities.

    Science.gov (United States)

    Devan, Michelle R; Pescatello, Linda S; Faghri, Pouran; Anderson, Jeffrey

    2004-09-01

    OBJECTIVE: To prospectively examine the influence of hamstring-to-quadriceps (H:Q) ratio and structural abnormalities on the prevalence of overuse knee injuries among female collegiate athletes. DESIGN AND SETTING: We used chi-square 2 x 2 contingency tables and the Fischer exact test to examine associations among H:Q ratios, structural abnormalities, and overuse knee injuries. SUBJECTS: Fifty-three apparently healthy women (age = 19.4 +/- 1.3 years, height = 167.6 +/- 10.1 cm, mass = 65.0 +/- 10.0 kg) from National Collegiate Athletic Association Division I women's field hockey (n = 23), soccer (n = 20), and basketball teams (n = 10) volunteered. MEASUREMENTS: The H:Q ratio was determined from a preseason isokinetic test on a Biodex system at 60 degrees /s and 300 degrees /s. We measured athletes for genu recurvatum and Q-angles with a 14-in (35.56-cm) goniometer. Iliotibial band flexibility was assessed via the Ober test. RESULTS: Ten overuse knee injuries (iliotibial band friction syndromes = 5, patellar tendinitis = 3, patellofemoral syndrome = 1, pes anserine tendinitis = 1) occurred in 9 athletes. The H:Q ratio below the normal range at 300 degrees /s (P = 0.047) was associated with overuse knee injuries, as was the presence of genu recurvatum (P = 0.004). In addition, athletes possessing lower H:Q ratios at 300 degrees /s and genu recurvatum incurred more overuse knee injuries than athletes without these abnormalities (P = 0.001). CONCLUSIONS: The presence of genu recurvatum and an H: Q ratio below normal range was associated with an increased prevalence of overuse knee injuries among female collegiate athletes. Further investigation is needed to clarify which preseason screening procedures may identify collegiate athletes who are susceptible to overuse knee injuries.

  15. Effects of Pilates and yoga in patients with chronic neck pain: A sonographic study

    Directory of Open Access Journals (Sweden)

    Naime Uluğ

    2017-10-01

    Full Text Available Background: Various studies have shown the efficacy of conventional isometric, Pilates and yoga exercises. However, data on the effects and comparison of these specific exercises on the cervical muscle morphology are insufficient or lacking. Objective: To investigate the effects of different exercise treatments on neck muscles in patients with chronic neck pain. Design: A randomized study. Methods: Fifty-six patients with chronic neck pain were randomized into 3 groups as follows: Pilates group (n = 20, yoga group (n = 18 and isometric group (n = 18. Demographics and background information were recorded. The thickness and cross-sectional area of neck muscles were evaluated by ultrasound imaging. Cervical motions were measured with a goniometer. Pain severity was evaluated with the McGill Pain Scale, disability with the Neck Disability Index, quality of life with the Nottingham Health Profile, and emotional status with the Beck Depression Inventory. In addition to a conventional physio-therapy programme, 15 sessions of physical therapy, including hot pack, ultrasound, and transcutaneous electrical nerve stimulation (TENS, were provided to all patients. All groups performed the exercises for 6 weeks. The aforementioned assessments were performed before and 6 weeks after the treatment. Results: Although pain, disability, depression and quality of life improved similarly within all groups (all p < 0.05, muscle thickness values as regards the semispinalis capitis were increased only in the Pilates group (p = 0.022. Study limitations: The lack of complex (progressive resistive exercise treatment protocols, short treatment duration and partial supervision. Conclusion: All 3 types of exercise had favourable effects on pain and functional scores, but no differences were found among the groups, except for the Pilates group, in which the semispinalis capitis muscle increased in thickness.

  16. Time-of-flight atom-probe field-ion microscope for the study of defects in metals. Report No. 2357

    International Nuclear Information System (INIS)

    Hall, T.M.; Wagner, A.; Berger, A.S.; Seidman, D.N.

    1975-06-01

    An ultra-high vacuum time-of-flight (TOF) atom-probe field ion microscope (FIM) specifically designed for the study of defects in metals is described. The variable magnification FIM image is viewed with the aid of an internal image intensification system based on a channel electron-multiplier array. The specimen is held in a liquid-helium-cooled goniometer stage, and the specimen is exchanged by means of a high-vacuum (less than 10 -6 torr) specimen exchange device. This stage allows the specimen to be maintained at a tip temperature anywhere in the range from 13 to 450 0 K. Specimens can also be irradiated in-situ with any low-energy (less than 1 keV) gas ion employing a specially constructed ion gun. The pulse-field evaporated ions are detected by a Chevron ion-detector located 2.22 m from the FIM specimen. The TOF of the ions are measured by a specially constructed eight-channel digital timer with a resolution of +-10 ns. The entire process of applying the evaporation pulse to the specimen, measuring the dc and pulse voltages, and analyzing the TOF data is controlled by a NOVA 1220 computer. The computer is also interfaced to a Tektronix graphics terminal which displays the data in the form of a histogram of the number of events versus the mass-to-charge ratio. An extensive set of computer programs to test and operate the atom-probe FIM have been developed. With this automated system we can presently record and analyze 10 TOF s -1 . In the performance tests reported here the instrument has resolved the seven stable isotopes of molybdenum, the five stable isotopes of tungsten, and the two stable isotopes of rhenium in a tungsten--25 at. percent rhenium alloy

  17. Measurement of angles of abduction for diagnosis of shoulder instability in dogs using goniometry and digital image analysis.

    Science.gov (United States)

    Cook, James L; Renfro, Daniel C; Tomlinson, James L; Sorensen, Jill E

    2005-01-01

    To compare abduction angles of shoulders with medial instability and unaffected shoulders in the same dogs and in age- and breed-matched dogs. Case-control study. Dogs with medial instability of the shoulder (n=33) and 26 control dogs. Dogs were sedated and positioned in lateral recumbency with both scapulas parallel to the table. With the elbow and shoulder in extension, the non-recumbent limb was maximally abducted and the angle between the scapular spine and lateral aspect of the brachium measured with a goniometer; a digital image was taken from the cranial aspect. Both techniques were performed in triplicate by 2 examiners. Mean abduction angles for each shoulder were determined from goniometric measurements and image analysis. Data were analyzed for significant differences between affected and unaffected shoulders, measurement techniques, and examiners. Strength of correlation between measurement techniques was determined. Mean abduction angles for shoulders with instability (53.7+/-4.7 degrees goniometric, 51.2+/-4.9 degrees image) were significantly (P<.001) larger than for all unaffected shoulders (32.6+/-2.0 degrees goniometric, 30.9+/-2.3 degrees image). In dogs diagnosed with instability, affected shoulders had significantly (P<.001) larger abduction angles than the contralateral (unaffected) shoulders. No significant differences were identified between right and left shoulders for control dogs, measurement techniques, or examiners. A strong (r=0.90) significant (P<.001) positive correlation between measurement techniques was noted. Shoulder abduction angles measured under sedation provide objective data for diagnosis of shoulder instability in dogs. Shoulders with clinical and arthroscopic evidence of medial instability have significantly higher abduction angles than shoulders that are considered normal. Determination of shoulder abduction angles should be included in the diagnostic protocol for forelimb lameness assessment in dogs.

  18. Posterior chain flexibility and lower back pain in farm workers

    Directory of Open Access Journals (Sweden)

    Marcia Regina da Silva

    Full Text Available Abstract Introduction: Flexibility is an essential component of physical aptitude that reduces the incidence of muscle distention and improves movement efficiency and posture. Objective: To analyze posterior chain flexibility and lower back pain (LBP in farm workers from a city in western Santa Catarina state, Brazil. Methods: Quantitative and cross-sectional study conducted with 185 rural workers, average age of 44.24 (±10.83 years. The Rural Worker Health Questionnaire, containing individual issues related to work; sit and reach box, goniometer, visual analog scale (VAS and Oswestry and Roland-Morris questionnaires were used to evaluate posterior chain flexibility, hamstring muscle length, pain and lumbar spine dysfunction, respectively. Flexibility was compared with the degree of dysfunction using one-way ANOVA followed by the Bonferroni post hoc test. Results: 181 (97.8% workers reported LBP symptoms: 100% of the women and 95.2% of the men. The average Oswestry score was 7.09 (±8.25, Roland-Morris 1.22 (±1.63, and VAS 5.81 (±2.5. Average flexibility by the sit and reach test (SRT was 23.91cm (±18.81; straight leg raise (SLR, 66° (±11.77 and popliteal angle 123.21° (±12.45. There was a significant difference in the popliteal angle (p = 0.003 and SLR (0.001 when compared with the degree of dysfunction. Women showed significant differences in all tests; however, the post hoc test showed a significant difference only in the SRT (p = 0.013, and women with minimal dysfunction had greater flexibility in relation to those with severe dysfunction. Conclusion: Self-reported LBP was severe and women with higher levels of dysfunction exhibited less posterior chain flexibility.

  19. Enhancement of antibacterial properties of polyurethanes by chitosan and heparin immobilization

    International Nuclear Information System (INIS)

    Kara, Filiz; Aksoy, E. Ayse; Yuksekdag, Zehranur; Aksoy, Serpil; Hasirci, Nesrin

    2015-01-01

    Graphical abstract: - Highlights: • Polyurethane elastomer was synthesized in medical purity. • Chitosan (CH) and heparin (Hep) were immobilized on polyurethane films. • Modification with CH and Hep increased hydrophilicity and surface free energy. • Immobilized films had high antibacterial activity against four bacteria. • Bacterial adhesion significantly decreased on the modified surfaces. - Abstract: Being antibacterial is a required property for the materials used in medical devices and instruments. Polyurethanes (PUs) are one class of polymers widely used in the production of devices that especially come in contact with blood (e.g. heart valves, blood vessels, vascular grafts and catheters). In this study, hexamethylene diisocyanate based polyurethanes (PUh) were synthesized and antibacterial and anti-adhesive properties were added by immobilizing chitosan (CH) and heparin (Hep) on the samples of PUh via a stepwise process. Chemistry and topography of the modified film samples (PUh-CH and PUh-CH-Hep) were examined by Fourier Transform Infrared Spectrophotometry-Attenuated Total Reflectance (FTIR-ATR), Electron Spectroscopy for Chemical Analysis (ESCA) and Atomic Force Microscopy (AFM), and surface free energy (SFE) values after each step were determined by goniometer. PUh-CH and PUh-CH-Hep samples were found to be antibacterial against Staphylococcus aureus (S. aureus) and Staphylococcus epidermidis (S. epidermidis) (both Gram positive) and Escherichia coli (E. coli) and Pseudomonas aeruginosa (P. aeruginosa) (both Gram negative) bacteria, and bacterial adhesion results showed a significant decrease in the number of viable bacteria on both modified samples where PUh-CH-Hep was the most effective. The findings of this study show that polymeric surfaces can be effectively modified and converted to be antibacterial by chitosan and heparin immobilization, and presence of both chemicals enhance efficacy against bacteria.

  20. Correlation of glenohumeral internal rotation deficit and total rotational motion to shoulder injuries in professional baseball pitchers.

    Science.gov (United States)

    Wilk, Kevin E; Macrina, Leonard C; Fleisig, Glenn S; Porterfield, Ronald; Simpson, Charles D; Harker, Paul; Paparesta, Nick; Andrews, James R

    2011-02-01

    Glenohumeral internal rotation deficit (GIRD) indicates a 20° or greater loss of internal rotation of the throwing shoulder compared with the nondominant shoulder. To determine whether GIRD and a deficit in total rotational motion (external rotation + internal rotation) compared with the nonthrowing shoulder correlate with shoulder injuries in professional baseball pitchers. Case series; Level of evidence, 4. Over 3 competitive seasons (2005 to 2007), passive range of motion measurements were evaluated on the dominant and nondominant shoulders for 170 pitcher-seasons. This included 122 professional pitchers during the 3 seasons of data collection, in which some pitchers were measured during multiple seasons. Ranges of motion were measured with a bubble goniometer during the preseason, by the same examiner each year. External and internal rotation of the glenohumeral joint was assessed with the participant supine and the arm abducted 90° in the plane of the scapula, with the scapula stabilized anteriorly at the coracoid process. The reproducibility of the test methods had an intraclass correlation coefficient of .81. Days in which the player was unable to participate because of injury or surgery were recorded during the season by the medical staff of the team and defined as an injury. Pitchers with GIRD (n = 40) were nearly twice as likely to be injured as those without but without statistical significance (P = .17). Pitchers with total rotational motion deficit greater than 5° had a higher rate of injury. Minor league pitchers were more likely than major league pitchers to be injured. However, when players were injured, major league pitchers missed a significantly greater number of games than minor league pitchers. Compared with pitchers without GIRD, pitchers with GIRD appear to be at a higher risk for injury and shoulder surgery.

  1. A PROSPECTIVE STUDY OF SUPRACONDYLAR FRACTURES OF THE HUMERUS IN CHILDREN TREATED BY CLOSED REDUCTION

    Directory of Open Access Journals (Sweden)

    Ch. Imobi

    2015-08-01

    Full Text Available There is no universal agreement regarding the management of displaced supracondylar fracture of the humerous in children. According to some orthopaedic surgeon almost all supracondylar humeral fractures should be treated operatively by reduction and pinning. While according to others closed reduction and pinning should be used for Gartland type II and some type III fractures. We present 50 cases of displaced supracondylar fracture treated by closed manipulative reduction under G.A. and immobilization with a posterior plaster of paris slab and collar and cuff. OBJECTIVE : T o assess the functional results of the injured elbow and to study the incidence of change in the carrying angle of the elbow. MATERIALS AND METHODS: This prospective study was conducted in 50 patients with extension type of displaced supracondylar fractures of humerus in children (Gartland type II and type III treated by closed manipulative reduction and immobilization in flexion of the elbow with a posterior plaster of paris slab and collar and cuff. Patients were followed up for 6 months. Flexion type of supracondylar fracture and those fractures which are absolutely indicated for operative intervention, Viz an open fracture and severe vascular compromise were excluded from the study. The range of movement and carrying angle was measured with the help of a Goniometer and Flynn criteria were used for functional assessment. RESULTS: At the end of follow up period, the end results were graded as excellent in 40%, good in 42%, fair in 12% and poor in 6%. A satisfactory result was therefore obtained in 94% and unsatisfactory result in 6% of the 50 patients who were followed and evaluated. CONCLUSION: This closed method of treatment for all practical proposes produces least complications, shorter hospital stay, can be expected to yield reproducible consistent satisfactory results not surpassed by any other method of treatment.

  2. FIGIFIGO as a tool to characterize and identify planetary analogue sites

    Science.gov (United States)

    Gritsevich, M.; Peltoniemi, J.; Hakala, T.; Muinonen, K.

    2014-07-01

    We present an overview of the Finnish Geodetic Institute's field goniospectrometer (FIGIFIGO) and highlight its usability to study extraterrestrial analogues on the Earth. The design concept of this custom-made instrument has been proved to have a number of advantages, such as a well-adopted user-friendly interface, a high level of automation, and excellent suitability for field measurements within a wide range of weather conditions. It is perfect for collection of reference data on a given target in natural undisturbed (and well-recorded for further data interpretation) conditions. The instrument communicates via a controlled computer with an implemented simple and user-friendly interface. This allows users to easily set up optional parameters at the beginning of the measurement series. Thus a number of details may be modified, such as the initial position of the sensor, the range and speed of further automated zenith turns, and length of the turnable arm holding the selected optics (including an option for a computer-turned linear polarizer) above the target. The assembly and operation of the instrument are fast and efficient in both laboratory and field conditions. It is battery powered and easily portable, including possible transportation by plane, car, boat, or sledge. The system includes a sky camera to detect the goniometer orientation and a pyranometer to monitor the actual illumination conditions. A fine-tune mirror is used for spatial correction of the optics footprint. Recent calibration of the system has significantly increased the measurement robustness and data reliability, and has provided the operators with information on how to operate the instrument in the most efficient and accurate way. Measurement campaigns are organized frequently and significant amount of reference data has been already collected. The identification of new planetary analogue sites and characterization of known ones using FIGIFIGO could offer new possibilities and provide

  3. Surface modification of gutta-percha cones by non-thermal plasma

    Energy Technology Data Exchange (ETDEWEB)

    Prado, Maíra, E-mail: maira@metalmat.ufrj.br [Department of Metallurgic and Materials Engineering, Federal University of Rio de Janeiro – UFRJ, Rio de Janeiro, RJ (Brazil); Menezes, Marilia Santana de Oliveira [Department of Metallurgic and Materials Engineering, Federal University of Rio de Janeiro – UFRJ, Rio de Janeiro, RJ (Brazil); Gomes, Brenda Paula Figueiredo de Almeida [Department of Restorative Dentistry, Endodontics Division, Piracicaba Dental School, State University of Campinas - UNICAMP, Piracicaba, SP (Brazil); Barbosa, Carlos Augusto de Melo [Department of Clinical Dentistry, Endodontic Division, Federal University of Rio de Janeiro – UFRJ, Rio de Janeiro, RJ (Brazil); Athias, Leonardo [Social Indicators Division, Brazilian Institute of Geography and Statistics, Rio de Janeiro, RJ (Brazil); Simão, Renata Antoun [Department of Metallurgic and Materials Engineering, Federal University of Rio de Janeiro – UFRJ, Rio de Janeiro, RJ (Brazil)

    2016-11-01

    This study was designed to evaluate the effects of Oxygen and Argon plasma on gutta-percha surfaces. A total of 185 flat smooth gutta-percha surfaces were used. Samples were divided into groups: control: no plasma treatment; Oxygen: treatment with Oxygen plasma for 1 min; Argon: treatment with Argon plasma for 1 min. Samples were evaluated topographically by scanning electron microscopy and atomic force microscopy; and chemically by Fourier Transform-infrared Spectroscopy. A goniometer was used to determine the surface free energy and the wettability of the endodontic sealers. Additionally 60 bovine teeth were filled using pellets of gutta-percha (control, oxygen and argon plasma) and the sealers. Teeth were evaluated by push-out and microleakage tests. Data were statistically analyzed using specific tests. Argon plasma did not change the surface topography, while Oxygen plasma led to changes. Both treatments chemically modified the gutta-percha surface. Argon and Oxygen plasma increased the surface free energy and favored the wettability of AH Plus and Pulp Canal Sealer EWT. Regarding bond strength analysis, for AH Plus sealer, both plasma treatments on gutta-percha favored the bond strength to dentin. However, for Pulp Canal Sealer, there is no statistically significant influence. For leakage test, dye penetration occurred between sealer and dentin in all groups. In conclusion, Oxygen plasma led to both topographic and chemical changes in the gutta-percha surface, while Argon plasma caused only chemical changes. Both treatments increased the surface free energy, favoring the wettability of AH Plus and Pulp Canal Sealer EWT sealers and influenced positively in the adhesion and leakage. - Highlights: • Argon plasma did not change the gutta-percha surface. • Oxygen plasma led to topographic changes. • Both treatments chemically modified the gutta-percha surface. • Treatments increased the surface free energy and favored the wettability of sealers. • Plasma

  4. Surface modification of gutta-percha cones by non-thermal plasma

    International Nuclear Information System (INIS)

    Prado, Maíra; Menezes, Marilia Santana de Oliveira; Gomes, Brenda Paula Figueiredo de Almeida; Barbosa, Carlos Augusto de Melo; Athias, Leonardo; Simão, Renata Antoun

    2016-01-01

    This study was designed to evaluate the effects of Oxygen and Argon plasma on gutta-percha surfaces. A total of 185 flat smooth gutta-percha surfaces were used. Samples were divided into groups: control: no plasma treatment; Oxygen: treatment with Oxygen plasma for 1 min; Argon: treatment with Argon plasma for 1 min. Samples were evaluated topographically by scanning electron microscopy and atomic force microscopy; and chemically by Fourier Transform-infrared Spectroscopy. A goniometer was used to determine the surface free energy and the wettability of the endodontic sealers. Additionally 60 bovine teeth were filled using pellets of gutta-percha (control, oxygen and argon plasma) and the sealers. Teeth were evaluated by push-out and microleakage tests. Data were statistically analyzed using specific tests. Argon plasma did not change the surface topography, while Oxygen plasma led to changes. Both treatments chemically modified the gutta-percha surface. Argon and Oxygen plasma increased the surface free energy and favored the wettability of AH Plus and Pulp Canal Sealer EWT. Regarding bond strength analysis, for AH Plus sealer, both plasma treatments on gutta-percha favored the bond strength to dentin. However, for Pulp Canal Sealer, there is no statistically significant influence. For leakage test, dye penetration occurred between sealer and dentin in all groups. In conclusion, Oxygen plasma led to both topographic and chemical changes in the gutta-percha surface, while Argon plasma caused only chemical changes. Both treatments increased the surface free energy, favoring the wettability of AH Plus and Pulp Canal Sealer EWT sealers and influenced positively in the adhesion and leakage. - Highlights: • Argon plasma did not change the gutta-percha surface. • Oxygen plasma led to topographic changes. • Both treatments chemically modified the gutta-percha surface. • Treatments increased the surface free energy and favored the wettability of sealers. • Plasma

  5. The challenge of teaching astronomy with 0 dollars

    Science.gov (United States)

    Ros, Rosa Maria; García, Beatriz

    2015-08-01

    The training courses on Astronomy are necessary for teachers in all the countries. Normally they are more necessary in developing countries that in other ones. The challenge is to do this work without expenses. NASE, Network for Astronomy School Education, organizes courses for teachers in service and future teachers practically free of charge. The host country only pays accommodation and meals of NASE visitors. But the most interesting aspect of NASE is that presents a lot of activities to carry out in the classroom by 0 dollars using “learning by doing” methodology. After more than 60 courses in about 20 countries we can show several examples of materials generated by participants themselves during the course. With this materials they can make observations and reasoning about their observations in order to understand the astronomy concepts which appear in the curricula of different levels of formal education.Waste materials, cardboard or paper, pieces of string or wire, a stick or a CD, some milk or a drop of oil can be very useful to produce a spectrograph, a photometer, a sundial, a goniometer or a quadrant. The imagination and creativity can replace funding which are difficult to achieve in secondary and primary schools in small towns or villages. NASE is a solution for teachers. which discover that they can explain, in a simple way, complex concepts using models and observations that do not need any money!Participants in NASE courses receive instructions in order to work with NASE materials and after the courses they can find (and create) complementary materials at the NASE website, in order to continue working in the same way. We receive some contributions from some of them that we publish at our web.http:www.naseprogram.org

  6. PA03.05. Masha taila as a preventive measure in gulpha marma injuries.

    Science.gov (United States)

    Dhaded, Rajani; Kulkarni, BG

    2013-01-01

    Purpose: In Basketball game Gulpha Marma injuries are common. Wrong landing causes inflammation & tearing of ligament resulting into sprain. Prevention can be carried out by protective wears like Ankelet,crape bandge which gives temporary recovery. Assessment and evaluation of the application of Masha Taila as a Snehana and Avagaha Sweda as a preventive measure for Gulpha Marma injuries. Method: 30 players with Normal ankle joint (Group A) & 30 players with Ankle sprain (1st degree) of Basketball players (Group B) were taken with age group 13 to 25 yrs. Goniometer to measure Range of motion (R.O.M.), pain analog scale for pain gradation. Result: Group A and B were compared with their control groups. The statistical result for normal dorsiflexion was 0.0007 degree, plantar flexion 0.001 degree, dorsi flexion of ankle sprain players 0.002 degree, plantar flexion 0.03 degree. The measurement of ROM of all players increased by 510 times indicating increased joint flexibility, based on ROM Mash taila proved to be a preventive measure. Pain analog scale for group B players indicated moderate pain at 0 day,reduced by 50% on 15th day and completely reduced on 30th day. Conclusion: “Prevention is better than cure”. As a preventive aspect the application of Masha Taila in normal ankle joint as Snehan & Swedan with warm water increases flexibility of joint and muscle strength. In sprained joint the same Taila application relives pain and regains its movements, this recovery and strength of joints happens because of reduce adhesion & influence the direction of new collage fibres in the healing process. It eliminates toxic accumulation from secondary muscle spasm. These Marma being the vital points must be prevented by applying Snehan & Swedan before starting the game just as warm up.

  7. Abductor pollicis longus tendon interposition for arthrosis of the first carpo-metacarpal joint. Long-term results.

    Science.gov (United States)

    Lied, Line; Bjørnstad, Kari; Woje, Ann K N; Finsen, Vilhjalmur

    2016-02-01

    We performed an interposition arthroplasty using the abductor pollicis longus tendon for arthrosis in the basal joint of the thumb that needed surgery from 1995 to 2010. In 2001 47 patients (55 thumbs) were reviewed after 3.5 (1-5) years. The pain relief was excellent in 32 thumbs, and 25 patients improved their ability to perform daily tasks. Mobility was well preserved. Key pinch and grip strengths averaged 78% and 89%, respectively, of those in unaffected hands. We have now re-examined all 33 available patients (36 thumbs) 11-14 years after surgery. Fourty one of the originally examined patients were still alive. Seven were too ill to attend a follow-up and one refused. The remainder were examined in a fashion as similar as possible to that at the original review. The patients' subjective estimations of pain during the last week and satisfaction with the cosmetic and general results were recorded on visual analogue scales. The patients' ability to perform various activities of daily living were recorded and they completed the Disability of the arm, shoulder and hand (DASH) questionnaire. The mobility of the wrist and abduction of the thumb of the operated hands were recorded with a goniometer. Grip and pinch strength were measured and new radiographs were obtained. Key pinch strength had increased significantly over the last 10 years. The mobility was still good, except for thumb abduction, which had decreased with time. The median DASH score had fallen from 28 to 20 between the two reviews. There was insignificant further median loss of distance between the scaphoid and the metacarpal since the earlier review. The good results of this procedure found soon after surgery are maintained long-term.

  8. Evaluation of gamma ray fields by HPGE spectrometry in situ

    Energy Technology Data Exchange (ETDEWEB)

    Krnac, S; Slugen, V [Slovak Technical Univ., Bratislava (Slovakia); Ragan, P; Fueloep, M [Inst. of Preventive and Clinical Medicine, Bratislava (Slovakia)

    1996-12-31

    In this paper the in situ spectrometric measurement for application in gamma radiation dosimetry with portability and flexibility in use was studied. In order to allow operation of the detector in any orientation without liquid nitrogen (LN{sub 2}) spillage, a multi-attitude cryostat (MAC) has been used which consists of a Dewar with LN{sub 2} capacity of 7.0 litres and a holding time of 5 days. This allows the Dewar to be operated in the horizontal position, pointing vertically upward or vertically downward, without loss of LN{sub 2}. The MAC detector has been positioned in a 4{sup p}i{sup -}goniometer and, therefore is movable to any measurable angle. Pulses from the detector have been fed into a portable multichannel analyzer (Canberra 35+) with connection to a PC/AT compatible computer system. The main results and findings of present contribution may be summarized as follows: 1. A technique called the scaling confirmatory factor analysis (SCFA) presented else can be advantageously employed for determination of the response operator characterizing an influence of measuring device on physical gamma-spectra obtained. The in situ response operator has been reproduced only from the internal factors of appropriate latent structure that do not depend upon materials surrounding the detector. 2. The photon fluence rate response operator for in situ application has been obtained from the reduced response operator by a correction according to the geometric factor 4{sup p}i{sup (}r{sub 0}+r){sup 2}.The effective distance r{sub 0} has been determined via a performance of the radial calibration which yields a condition of, minimally, 10 cm distance of the detector cover from the potential sources. 3. The real incident gamma ray spectra achieved by application of the SCFA response allow direct evaluation of spectral distributions of the fundamental photon dosimetric quantities. (Abstract Truncated)

  9. Evaluation of malrotation following intramedullary nailing in a femoral shaft fracture model: Can a 3D c-arm improve accuracy?

    Science.gov (United States)

    Ramme, Austin J; Egol, Jonathan; Chang, Gregory; Davidovitch, Roy I; Konda, Sanjit

    2017-07-01

    Difficulty determining anatomic rotation following intramedullary (IM) nailing of the femur continues to be problematic for surgeons. Clinical exam and fluoroscopic imaging of the hip and knee have been used to estimate femoral version, but are inaccurate. We hypothesize that 3D c-arm imaging can be used to accurately measure femoral version following IM nailing of femur fractures to prevent rotational malreduction. A midshaft osteotomy was created in a femur Sawbone to simulate a transverse diaphyseal fracture. An intramedullary (IM) nail was inserted into the Sawbone femur without locking screws or cephalomedullary fixation. A goniometer was used to simulate four femoral version situations after IM nailing: 20° retroversion, 0° version, 15° anteversion, and 30° anteversion. In each simulated position, 3D c-arm imaging and, for comparison purposes, perfect lateral radiographs of the knee and hip were performed. The femoral version of each simulated 3D and fluoroscopic case was measured and the results were tabulated. The measured version from the 3D c-arm images was 22.25° retroversion, 0.66° anteversion, 19.53° anteversion, and 25.15° anteversion for the simulated cases of 20° retroversion, 0° version, 15° anteversion, and 30° anteversion, respectively. The lateral fluoroscopic views were measured to be 9.66° retroversion, 12.12° anteversion, 20.91° anteversion, and 18.77° anteversion for the simulated cases, respectively. This study demonstrates the utility of a novel intraoperative method to evaluate femur rotational malreduction following IM nailing. The use of 3D c-arm imaging to measure femoral version offers accuracy and reproducibility. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Preparation and mass spectrometrical high temperature investigations on compounds of the quasi-ternary system Cs2O-Al2O3-SiO2

    International Nuclear Information System (INIS)

    Odoj, R.; Hilpert, K.; Nuernberg, H.W.

    1977-09-01

    Additions of aluminium oxide and silicen oxide to ceramic fuel for pyrocarbon-coated nuclear fuel paticles counteract a release of fission-cesium by compound formation. The vapourization tests carried out here using samples from the quasi-ternary system cesium-oxide-aluminium-oxide-silicon-oxide by means of high-temperature mass spectroscopy using a Knudsen cell served the optimization of this retention effect. The aim of the apparative changes on the knudsen cell were to shield heat radiation on the temperature measuring borehole through the tungsten wire cathode in order to be able to perform exact temperature measurements even below 1,000 0 C. A new method of preparation was developed to obtain defined cesium aluminium silicates whose composition was determined by Guinier and goniometer pictures as well as by microscopic investigations. According to the latter, 3 ternary compounds are present in the system investigated: CsAlSiO 4 , CsAlSi 2 O 6 and CsAlSi 5 O 12 . Their lattice constants were determined from goniometric measurements; the vapour pressure equection were set up from the measured cesium vapour pressure values over each sample and the enthalpies of the vapourization reactions were found to be 84 kcal for CsAlSiO 4 at 1,400 0 K, 100 kcal for CsAlSi 2 O 6 at 1,550 0 K and 122 kcal for CsAlSi 5 O 12 at 1,650 0 K. The cesium vapour pressures of the glas phases investigated of the system are above the Cs partial pressures of the solid crystalline phases of the same composition. The results of the work explain the causes of the reduction of the Cs release and show that the vapour pressure can be lowered by more than 10 orders of magnitude at reactor relevant temperatures by compound formation. (RB) [de

  11. EFFECTIVENESS OF INSTUMENTAL ASSISTED SOFT TISSUE MOBILIZATION TECHNIQUE WITH STATIC STRETCHING IN SUBJECTS WITH PLANTAR FASCIITIS

    Directory of Open Access Journals (Sweden)

    Vinod Babu. K

    2014-08-01

    Full Text Available Background: Instrumental assisted soft tissue mobilization and static stretching found to be effective in plantar fasciitis, however the combined effectiveness of these techniques were unknown. The purpose of this study is to find the effect of Instrumental assisted soft tissue mobilization technique for plantar fascia combined with static stretching of triceps surae for subjects with chronic stage of Plantar Fasciitis on pain intensity, ankle dorsiflexion range of motion and functional disability. Methods: An experimental study design, selected subjects with chronic Plantar Fasciitis randomized subjects into each Study and Control group. Total of 40 subject’s data who completed study, 20 in each group, was used for analysis. Control group received conventional exercise while Study group received conventional exercises with Instrumental assisted soft tissue mobilization combined with static stretching of triceps surae muscle. Outcome measurements such as Intensity of pain using Numerical Pain Rating Scale-101 (NPRS-101, function disability using Foot Function Index Pain Subscale (FFI and ankle dorsiflexion active range of motion using Goniometer was measured before and after 2 weeks of intervention. Results: There is statistically significant improvement in means of NRS-101, ankle dorsiflexion active range of motion and Foot Function Index Pain Subscale after intervention in both groups. When the post-intervention means were compared between Study and Control group after 2 weeks of treatment there is statistically significant difference in means between the groups whereas study group showed greater percentage of improvement than control group. Conclusion: It is concluded that Instrumental assisted soft tissue mobilization technique combined with static stretching of triceps surae muscle is significantly effective than conventional exercises on reducing pain, improving ankle dorsiflexion range of motion and functional disability for subjects

  12. Enhancement of antibacterial properties of polyurethanes by chitosan and heparin immobilization

    Energy Technology Data Exchange (ETDEWEB)

    Kara, Filiz [Department of Chemistry, Faculty of Science, Gazi University, 06500 Ankara (Turkey); Aksoy, E. Ayse [Department of Basic Pharmaceutical Sciences, Faculty of Pharmacy, Hacettepe University, 06100 Ankara (Turkey); Yuksekdag, Zehranur [Biotechnology Laboratory, Department of Biology, Faculty of Science, Gazi University, 06500 Ankara (Turkey); Aksoy, Serpil [Department of Chemistry, Faculty of Science, Gazi University, 06500 Ankara (Turkey); Hasirci, Nesrin, E-mail: nhasirci@metu.edu.tr [BIOMATEN, Center of Excellence in Biomaterials and Tissue Engineering, Middle East Technical University, 06800 Ankara (Turkey); Department of Chemistry, Faculty of Arts and Sciences, Middle East Technical University, 06800 Ankara (Turkey)

    2015-12-01

    Graphical abstract: - Highlights: • Polyurethane elastomer was synthesized in medical purity. • Chitosan (CH) and heparin (Hep) were immobilized on polyurethane films. • Modification with CH and Hep increased hydrophilicity and surface free energy. • Immobilized films had high antibacterial activity against four bacteria. • Bacterial adhesion significantly decreased on the modified surfaces. - Abstract: Being antibacterial is a required property for the materials used in medical devices and instruments. Polyurethanes (PUs) are one class of polymers widely used in the production of devices that especially come in contact with blood (e.g. heart valves, blood vessels, vascular grafts and catheters). In this study, hexamethylene diisocyanate based polyurethanes (PUh) were synthesized and antibacterial and anti-adhesive properties were added by immobilizing chitosan (CH) and heparin (Hep) on the samples of PUh via a stepwise process. Chemistry and topography of the modified film samples (PUh-CH and PUh-CH-Hep) were examined by Fourier Transform Infrared Spectrophotometry-Attenuated Total Reflectance (FTIR-ATR), Electron Spectroscopy for Chemical Analysis (ESCA) and Atomic Force Microscopy (AFM), and surface free energy (SFE) values after each step were determined by goniometer. PUh-CH and PUh-CH-Hep samples were found to be antibacterial against Staphylococcus aureus (S. aureus) and Staphylococcus epidermidis (S. epidermidis) (both Gram positive) and Escherichia coli (E. coli) and Pseudomonas aeruginosa (P. aeruginosa) (both Gram negative) bacteria, and bacterial adhesion results showed a significant decrease in the number of viable bacteria on both modified samples where PUh-CH-Hep was the most effective. The findings of this study show that polymeric surfaces can be effectively modified and converted to be antibacterial by chitosan and heparin immobilization, and presence of both chemicals enhance efficacy against bacteria.

  13. Duration and frequency of every day activities in total hip patients.

    Science.gov (United States)

    Morlock, M; Schneider, E; Bluhm, A; Vollmer, M; Bergmann, G; Müller, V; Honl, M

    2001-07-01

    Little knowledge about frequency and duration of daily activities in patients after total hip arthroplasty is available. Such information is required for the definition of realistic load collectives for pre-clinical testing of prostheses. It could also be helpful for the quantitative evaluation of surgery outcome with different prosthesis types. The purpose of this study was to develop and apply a system for the determination of frequency and duration of patient activities in their habitual environment and to compare the results to a clinical outcome score (Harris hip score).A portable activity monitoring system (weight 1.6 kg including batteries) was designed using a Palm top computer, 2 inclination sensors for the thigh and calf and one goniometer positioned at the knee joint. An algorithm was developed to identify frequency and duration of the activities lying, sitting, standing, walking and stair climbing from the signals of the 3 sensors. 42 patients participated in the study and were equipped with the system in the morning at their home. Datasets of 31 patients (age 62.5+/-11.5 y) covered more than 6h (9.8 +/- 1.6 h) and were included in the analysis. Prosthesis specific data as well as the Harris hip score were collected. The most frequent patient activity was sitting (44.3% of the time), followed by standing (24.5%), walking (10.2%), lying (5.8%) and stair climbing (0.4%). The median number of steps/stairs was 6048/164. The number of step cycles representing one year in vivo use should, consequently, be increased to 1.1 million. The Harris hip score (91.4 +/- 9.8) correlated significantly with the number of stairs (r(2) = 0.26, p = 0.003) and showed a positive tendency with the number of steps per day. No differences in activity levels between prosthesis specific factors were found.

  14. The reliability of knee joint position testing using electrogoniometry

    Directory of Open Access Journals (Sweden)

    Winter Adele

    2008-01-01

    Full Text Available Abstract Background The current investigation examined the inter- and intra-tester reliability of knee joint angle measurements using a flexible Penny and Giles Biometric® electrogoniometer. The clinical utility of electrogoniometry was also addressed. Methods The first study examined the inter- and intra-tester reliability of measurements of knee joint angles in supine, sitting and standing in 35 healthy adults. The second study evaluated inter-tester and intra-tester reliability of knee joint angle measurements in standing and after walking 10 metres in 20 healthy adults, using an enhanced measurement protocol with a more detailed electrogoniometer attachment procedure. Both inter-tester reliability studies involved two testers. Results In the first study, inter-tester reliability (ICC[2,10] ranged from 0.58–0.71 in supine, 0.68–0.79 in sitting and 0.57–0.80 in standing. The standard error of measurement between testers was less than 3.55° and the limits of agreement ranged from -12.51° to 12.21°. Reliability coefficients for intra-tester reliability (ICC[3,10] ranged from 0.75–0.76 in supine, 0.86–0.87 in sitting and 0.87–0.88 in standing. The standard error of measurement for repeated measures by the same tester was less than 1.7° and the limits of agreement ranged from -8.13° to 7.90°. The second study showed that using a more detailed electrogoniometer attachment protocol reduced the error of measurement between testers to 0.5°. Conclusion Using a standardised protocol, reliable measures of knee joint angles can be gained in standing, supine and sitting by using a flexible goniometer.

  15. Biomechanical assessment of balance and posture in subjects with ankylosing spondylitis

    Directory of Open Access Journals (Sweden)

    Sawacha Zimi

    2012-08-01

    Full Text Available Abstract Background Ankylosing spondylitis is a major chronic rheumatic disease that predominantly affects axial joints, determining a rigid spine from the occiput to the sacrum. The dorsal hyperkyphosis may induce the patients to stand in a stooped position with consequent restriction in patients’ daily living activities. The aim of this study was to develop a method for quantitatively and objectively assessing both balance and posture and their mutual relationship in ankylosing spondylitis subjects. Methods The data of 12 healthy and 12 ankylosing spondylitis subjects (treated with anti-TNF-α stabilized, with a mean age of 51.42 and 49.42 years; mean BMI of 23.08 and 25.44 kg/m2 were collected. Subjects underwent a morphological examination of the spinal mobility by means of a pocket compass needle goniometer, together with an evaluation of both spinal and hip mobility (Bath Ankylosing Spondylitis Metrology Index, and disease activity (Bath Ankylosing Spondylitis Disease Activity Index. Quantitative evaluation of kinematics and balance were performed through a six cameras stereophotogrammetric system and a force plate. Kinematic models together with a test for evaluating balance in different eye level conditions were developed. Head protrusion, trunk flexion-extension, pelvic tilt, hip-knee-ankle flexion-extension were evaluated during Romberg Test, together with centre of pressure parameters. Results Each subject was able to accomplish the required task. Subjects’ were comparable for demographic parameters. A significant increment was observed in ankylosing spondylitis subjects for knee joint angle with the target placed at each eye level on both sides (p  Conclusions Our findings confirm the need to investigate both balance and posture in ankylosing spondylitis subjects. This methodology could help clinicians to plan rehabilitation treatments.

  16. Laboratory reflectometer for the investigation of optical elements in a wavelength range of 5-50 nm: description and testing results

    Science.gov (United States)

    Garakhin, S. A.; Zabrodin, I. G.; Zuev, S. E.; Kas'kov, I. A.; Lopatin, A. Ya.; Nechay, A. N.; Polkovnikov, V. N.; Salashchenko, N. N.; Tsybin, N. N.; Chkhalo, N. I.; Svechnikov, M. V.

    2017-05-01

    We describe a laboratory reflectometer developed at the IPM RAS for precision measurements of spectral and angular dependences of the reflection and transmission coefficients of optical elements in a wavelength range of 5-50 nm. The radiation is monochromatised using a high-resolution Czerny-Turner spectrometer with a plane diffraction grating and two spherical collimating mirrors. A toroidal mirror focuses the probe monochromatic beam on a sample. The X-ray source is a highly ionised plasma produced in the interaction of a high-power laser beam with a solid target at an intensity of 1011-1012 W cm-2. To stabilise the emission characteristics, the target executes translatory and rotary motions in such a way that every pulse irradiates a new spot. The short-focus lens is protected from contamination by erosion products with the use of a specially designed electromagnetic system. The samples under study are mounted on a goniometer is accommodated in a dedicated chamber, which provides five degrees of freedom for samples up to 500 mm in diameter and two degrees of freedom for a detector. The sample mass may range up to 10 kg. The X-ray radiation is recorded with a detector composed of a CsI photocathode and two microchannel plates. A similar detector monitors the probe beam intensity. The spectral reflectometer resolution is equal to 0.030 nm with the use of ruled gratings with a density of 900 lines mm-1 (spectral range: 5-20 nm) and to 0.067 nm for holographic gratings with a density of 400 lines mm-1 (spectral range: 10-50 nm). We analyse the contribution of higher diffraction orders to the probe signal intensity and the ways of taking it into account in the measurements. Examples are given which serve to illustrate the reflectometer application to the study of multilayer mirrors and filters.

  17. Radiative Transfer of Solar Light in Dense Complex Media : Theoretical and Experimental Achievements by the Planetary Community

    Science.gov (United States)

    Doute, S.; Schmitt, B.

    2004-05-01

    particular Monte Carlo ray tracing simulations have been recently carried out to investigate properties of particulate media that are traditionally ignored or crudely treated: packing density, micro-roughness, etc. The efforts of the community to address the later problems are not only theoretical but also experimental with the development of several dedicated goniometers.

  18. Ultrasound guided versus landmark guided corticosteroid injection in patients with rotator cuff syndrome: Randomised controlled trial.

    Science.gov (United States)

    Bhayana, Himanshu; Mishra, Puneet; Tandon, Anupama; Pankaj, Amite; Pandey, Rohit; Malhotra, Raskesh

    2018-03-01

    Impingement syndrome is the most common differential in a patient presenting to an orthopaedic OPD with shoulder pain. Impingement syndrome is often managed with subacromial corticosteroid injection, which can be instilled using either landmark guided (LMG) approach or with the assistance of ultrasound (US). This study was envisaged to enquire whether ultrasound assistance improves the accuracy, efficacy or safety profile of the injection. 60 patients of rotator cuff syndrome underwent diagnostic ultrasound. They were randomly assigned to receive subacromial injection of 2 ml (40 mg/ml) methylprenisolone and 2 ml of 1% lignocaine combination either by US assistance (n = 30) or using LMG assistance (n = 30). The patients were evaluated before injection and on follow up visits at day 5, week 3, week 6 and 3rd month by a single assessor. The assessor was blinded of the treatment group to which patient belonged. Clinical assessment included demographic and clinical data, accuracy of injection, VAS (0-100) for pain, Constant score with goniometer evaluation of range of motion, patient's self assessment proforma and post injection side effects if any. Initial demographic, clinical and US findings in the groups exhibited no significant differences. The accuracy of US guided injections (100%) was more when compared from LMG injection (93.3%). Both VAS and Constant score showed significant improvement following steroid injection up to 3 months of follow up. However the differences in the two groups were not significant suggesting comparable efficacy of the two approaches. (Mean VAS score decrease: 27.23 for US and 25.16 for LMG, p guided injections have a higher accuracy of drug placement in the subacromial bursa, there is no difference in terms of clinical outcomes or safety profile of either of the method. Hence US guided injections seems to be unjustified, when compared to equally efficacious and cost effective LMG steroid injection.

  19. Refractive Index of Black and Green Liquors

    Directory of Open Access Journals (Sweden)

    E. A. Avramenko

    2015-01-01

    Full Text Available Lack of reliable data on the optical properties of black and green liquors complicates control of their composition in technological process of sulphate cellulose production. In this regard the paper presents measurement results of refraction index of black liquors n (k,t at concentration in solutions of bone-dry solids up to k = 70% and at temperatures t = 10-90 °C, as well as in green liquors n(C,t at the total alkalinity of C = 0-250 g/l and in the same temperature range. All samples of solutions of black and green liquors were provided by Segezha Pulp and Paper Mill and certified in factory laboratory. Measurements were taken by means of the laboratory Abbe refractometer (URL-1, digital refractometer "Expert pro", goniometer spectrometer GS-5, and ultra-violet spectrophotometer as well. The work also presents optical D density spectra in the ultra-violet region of the wavelengths for the samples of a green liquor and main mineral component to form it, i.e. Na2S (sodium sulphide. To calculate dispersion of n (λ in the visible spectral range, here a Lorentz single-oscillator model was used. The paper discusses study results of dispersive dependence of refraction index in green liquors with various concentration and chemical components of n (λ, C forming them at t = 20°C. Computing and experimental dependences of n (λ had not only good qualitative, but also quite satisfactory quantitative compliance. The work also describes main mineral components defining optical properties in these liquors. Given here data on concentration and temperature dependences of a refraction index in black n(k,t and green n(C,t liquors have been never published before. These data are of essential interest to control soda recovery technologies in manufacturing sulphate cellulose. The received results can be also used to tune and calibrate modern domestic and foreign industrial refractometers.

  20. The role of oxygen in quinternary superconductors.

    Energy Technology Data Exchange (ETDEWEB)

    Beckman, D.R.; Jamieson, D.N. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1996-12-31

    The oxygen composition of the new generation of high temperature superconductors (HTSC) has been found to play a crucial role in determining the superconductivity of these materials. However, measurement of the oxygen stoichiometry in such samples has proven difficult due to the small scattering cross section of oxygen, a light element, which has caused the oxygen scattering signal to be overwhelmed by the far larger signals generated off the heavier elements present in the HTSC samples. It is for this reason that previous ion beam analysis of oxide crystals has often either made no attempt to determine the oxygen content or has used O({alpha},{alpha})O resonances such as that at {approx} 3.05 MeV to probe the crystal. This work continues tests of a new technique for probing oxygen which overcomes the problem of an insignificant O BS signal by exploiting the large nuclear resonance found to occur in the O(p,p)O cross-section near an energy of 3.5 MeV in order to produce a significant oxygen edge in the H{sup +} BS spectrum obtained for the HTSC sample. The use of a H{sup +} beam is preferable to a He{sup 2+} beam for such work due to its enhanced sensitivity to light elements. The quinternary superconductor used for this investigation was a good quality pure Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+x} (BISCO, 2212) crystal. The size of this crystal was 5x5xl mm{sup 3} with the [001] face perpendicular to the surface. Measurements were performed using the University of Melbourne nuclear microprobe. The sample was mounted on an aluminium target holder using a carbon base adhesive which provided good electrical contact and it was oriented inside the target chamber by means of a four axis precision eucentric goniometer. 6 refs., 3 figs.

  1. Extracting time-frequency feature of single-channel vastus medialis EMG signals for knee exercise pattern recognition.

    Directory of Open Access Journals (Sweden)

    Yi Zhang

    Full Text Available The EMG signal indicates the electrophysiological response to daily living of activities, particularly to lower-limb knee exercises. Literature reports have shown numerous benefits of the Wavelet analysis in EMG feature extraction for pattern recognition. However, its application to typical knee exercises when using only a single EMG channel is limited. In this study, three types of knee exercises, i.e., flexion of the leg up (standing, hip extension from a sitting position (sitting and gait (walking are investigated from 14 healthy untrained subjects, while EMG signals from the muscle group of vastus medialis and the goniometer on the knee joint of the detected leg are synchronously monitored and recorded. Four types of lower-limb motions including standing, sitting, stance phase of walking, and swing phase of walking, are segmented. The Wavelet Transform (WT based Singular Value Decomposition (SVD approach is proposed for the classification of four lower-limb motions using a single-channel EMG signal from the muscle group of vastus medialis. Based on lower-limb motions from all subjects, the combination of five-level wavelet decomposition and SVD is used to comprise the feature vector. The Support Vector Machine (SVM is then configured to build a multiple-subject classifier for which the subject independent accuracy will be given across all subjects for the classification of four types of lower-limb motions. In order to effectively indicate the classification performance, EMG features from time-domain (e.g., Mean Absolute Value (MAV, Root-Mean-Square (RMS, integrated EMG (iEMG, Zero Crossing (ZC and frequency-domain (e.g., Mean Frequency (MNF and Median Frequency (MDF are also used to classify lower-limb motions. The five-fold cross validation is performed and it repeats fifty times in order to acquire the robust subject independent accuracy. Results show that the proposed WT-based SVD approach has the classification accuracy of 91.85%±0

  2. The role of oxygen in quinternary superconductors.

    Energy Technology Data Exchange (ETDEWEB)

    Beckman, D R; Jamieson, D N [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1997-12-31

    The oxygen composition of the new generation of high temperature superconductors (HTSC) has been found to play a crucial role in determining the superconductivity of these materials. However, measurement of the oxygen stoichiometry in such samples has proven difficult due to the small scattering cross section of oxygen, a light element, which has caused the oxygen scattering signal to be overwhelmed by the far larger signals generated off the heavier elements present in the HTSC samples. It is for this reason that previous ion beam analysis of oxide crystals has often either made no attempt to determine the oxygen content or has used O({alpha},{alpha})O resonances such as that at {approx} 3.05 MeV to probe the crystal. This work continues tests of a new technique for probing oxygen which overcomes the problem of an insignificant O BS signal by exploiting the large nuclear resonance found to occur in the O(p,p)O cross-section near an energy of 3.5 MeV in order to produce a significant oxygen edge in the H{sup +} BS spectrum obtained for the HTSC sample. The use of a H{sup +} beam is preferable to a He{sup 2+} beam for such work due to its enhanced sensitivity to light elements. The quinternary superconductor used for this investigation was a good quality pure Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+x} (BISCO, 2212) crystal. The size of this crystal was 5x5xl mm{sup 3} with the [001] face perpendicular to the surface. Measurements were performed using the University of Melbourne nuclear microprobe. The sample was mounted on an aluminium target holder using a carbon base adhesive which provided good electrical contact and it was oriented inside the target chamber by means of a four axis precision eucentric goniometer. 6 refs., 3 figs.

  3. Biological imaging by soft X-ray diffraction microscopy

    Science.gov (United States)

    Shapiro, David

    We have developed a microscope for soft x-ray diffraction imaging of dry or frozen hydrated biological specimens. This lensless imaging system does not suffer from the resolution or specimen thickness limitations that other short wavelength microscopes experience. The microscope, currently situated at beamline 9.0.1 of the Advanced Light Source, can collect diffraction data to 12 nm resolution with 750 eV photons and 17 nm resolution with 520 eV photons. The specimen can be rotated with a precision goniometer through an angle of 160 degrees allowing for the collection of nearly complete three-dimensional diffraction data. The microscope is fully computer controlled through a graphical user interface and a scripting language automates the collection of both two-dimensional and three-dimensional data. Diffraction data from a freeze-dried dwarf yeast cell, Saccharomyces cerevisiae carrying the CLN3-1 mutation, was collected to 12 run resolution from 8 specimen orientations spanning a total rotation of 8 degrees. The diffraction data was phased using the difference map algorithm and the reconstructions provide real space images of the cell to 30 nm resolution from each of the orientations. The agreement of the different reconstructions provides confidence in the recovered, and previously unknown, structure and indicates the three dimensionality of the cell. This work represents the first imaging of the natural complex refractive contrast from a whole unstained cell by the diffraction microscopy method and has achieved a resolution superior to lens based x-ray tomographic reconstructions of similar specimens. Studies of the effects of exposure to large radiation doses were also carried out. It was determined that the freeze-dried cell suffers from an initial collapse, which is followed by a uniform, but slow, shrinkage. This structural damage to the cell is not accompanied by a diminished ability to see small features in the specimen. Preliminary measurements on frozen

  4. Effect of proprioception training on knee joint position sense in female team handball players.

    Science.gov (United States)

    Pánics, G; Tállay, A; Pavlik, A; Berkes, I

    2008-06-01

    A number of studies have shown that proprioception training can reduce the risk of injuries in pivoting sports, but the mechanism is not clearly understood. To determine the contributing effects of propioception on knee joint position sense among team handball players. Prospective cohort study. Two professional female handball teams were followed prospectively for the 2005-6 season. 20 players in the intervention team followed a prescribed proprioceptive training programme while 19 players in the control team did not have a specific propioceptive training programme. The coaches recorded all exposures of the individual players. The location and nature of injuries were recorded. Joint position sense (JPS) was measured by a goniometer on both knees in three angle intervals, testing each angle five times. Assessments were performed before and after the season by the same examiner for both teams. In the intervention team a third assessment was also performed during the season. Complete data were obtained for 15 subjects in the intervention team and 16 in the control team. Absolute error score, error of variation score and SEM were calculated and the results of the intervention and control teams were compared. The proprioception sensory function of the players in the intervention team was significantly improved between the assessments made at the start and the end of the season (mean (SD) absolute error 9.78-8.21 degrees (7.19-6.08 degrees ) vs 3.61-4.04 degrees (3.71-3.20 degrees ), pteam between the start and the end of the season (mean (SD) absolute error 6.31-6.22 degrees (6.12-3.59 degrees ) vs 6.13-6.69 degrees (7.46-6.49 degrees ), p>0.05). This is the first study to show that proprioception training improves the joint position sense in elite female handball players. This may explain the effect of neuromuscular training in reducing the injury rate.

  5. The Effect of Eccentric Exercise-Induced Delayed-Onset Muscle Soreness on Positioning Sense and Shooting Percentage in Wheelchair Basketball Players

    Directory of Open Access Journals (Sweden)

    Mehmet Akif Serinken

    2013-12-01

    Full Text Available Background: Eccentric exercise is defined as a type of exercise in which the muscle produces power by extending. In contrast to isometric and concentric exercises, eccentric muscle activity is much more effective mechanically; however, it may expose the muscle to soreness. Delayed-Onset Muscle Soreness (DOMS emerges a couple of hours after an eccentric activity, especially in individuals who are not used to this kind of exercise, and causes a temporary decrease in muscle performance, joint movement angle and muscle power, and also a temporary increase in the blood creatine kinase (CK activity. Aims: This study investigates the effect of DOMS on the upper extremities motor performance by conducting an eccentric exercise load on the elbow flexor muscles. Study design: Cross sectional study. Methods: The study included 10 wheelchair basketball players. First, the participants underwent blood CK activity, positioning sense, muscle pain, shooting performance measurements tests at the base, and after 30 minutes and 24 and 48 hours. Then, one week later, the one-repetition-maximums of biceps curls were determined in order to define the intensity of the eccentric exercise. An eccentric exercise protocol which would cause DOMS was applied to all players. All tests were replaced with acute exhaustive eccentric exercise; the same tests were repeated in the same order after the exercise. Blood CK activity was measured by taking an earlobe capillary blood sample. The muscle pain level was measured by using a Visual Analogue Scale (VAS. Positioning sense loss was assessed via goniometer at 30º, 60º and 90º degrees horizontally. Results: The study found a statistically significant increase in blood CK activity and positioning sense loss, and a decrease in the pressure-pain threshold, as well as the shooting percentages in the exercise group when compared with the control. Conclusion: These findings suggest that DOMS negatively affects the upper extremities

  6. AN EVALUATION OF THE REARFOOT POSTURE IN INDIVIDUALS WITH PATELLOFEMORAL PAIN SYNDROME

    Directory of Open Access Journals (Sweden)

    Wendy Gilleard

    2004-11-01

    Full Text Available Structural abnormalities of the foot may cause abnormal subtalar joint compensatory motion in order to attain normal function of the lower extremity during gait although studies have not been conclusive. Current conflict in the literature may be related to the differing measures focused on the varying protocols and also the absence of a control group in some studies. This study investigated the rearfoot posture including Subtalar Joint Neutral Position (STJN and Relaxed Calcaneal Standing (RCS measurements in patellofemoral pain syndrome (PFPS and healthy subjects. The angle of STJN during non-weight bearing position and the two dimensional (2D rearfoot RCS posture was measured using a goniometer in 14 healthy females and 13 females with PFPS. The RCS posture was also measured three dimensionally (3D by attaching external markers to a tibia shell and the calcaneus and videoing with a four-camera three-dimensional motion analysis system. A one way ANOVA was used to assess the differences between the groups. The 2D and 3D RCS were significantly different between the groups (p ¡Ü 0.001 with mean -0.23¡ã ¡À 1.35¡ã , 2.52¡ã ¡À 3.11¡ã for the control group and 2.35¡ã ¡À 1.4¡ã, 7.02¡ã ¡À 3.33¡ã for the clinical group respectively. STJN showed a slight rearfoot varus (although significant p = 0.04 in PFPS (-2.20¡ã ¡À 1.51¡ã compared to the control group (-1.00¡ã ¡À 1.36¡ã. Negative values indicated inversion and positive values indicated eversion. The 2D and 3D RCS showed a significantly more everted posture of the rearfoot for the PFPS group. Subtalar joint varus may contribute to the increased eversion during relaxed standing in the PFPS group. Rearfoot measurements may be an important addition to other clinical measurements taken to explore the underlying aetiology of subjects with PFPS.

  7. Comparison of silver and molybdenum microfocus X-ray sources for single-crystal structure determination.

    Science.gov (United States)

    Krause, Lennard; Herbst-Irmer, Regine; Sheldrick, George M; Stalke, Dietmar

    2015-02-01

    The quality of diffraction data obtained using silver and molybdenum microsources has been compared for six model compounds with a wide range of absorption factors. The experiments were performed on two 30 W air-cooled Incoatec IµS microfocus sources with multilayer optics mounted on a Bruker D8 goniometer with a SMART APEX II CCD detector. All data were analysed, processed and refined using standard Bruker software. The results show that Ag  K α radiation can be beneficial when heavy elements are involved. A numerical absorption correction based on the positions and indices of the crystal faces is shown to be of limited use for the highly focused microsource beams, presumably because the assumption that the crystal is completely bathed in a (top-hat profile) beam of uniform intensity is no longer valid. Fortunately the empirical corrections implemented in SADABS , although originally intended as a correction for absorption, also correct rather well for the variations in the effective volume of the crystal irradiated. In three of the cases studied (two Ag and one Mo) the final SHELXL R 1 against all data after application of empirical corrections implemented in SADABS was below 1%. Since such corrections are designed to optimize the agreement of the intensities of equivalent reflections with different paths through the crystal but the same Bragg 2θ angles, a further correction is required for the 2θ dependence of the absorption. For this, SADABS uses the transmission factor of a spherical crystal with a user-defined value of μ r (where μ is the linear absorption coefficient and r is the effective radius of the crystal); the best results are obtained when r is biased towards the smallest crystal dimension. The results presented here suggest that the IUCr publication requirement that a numerical absorption correction must be applied for strongly absorbing crystals is in need of revision.

  8. G-paq: a motion control and data acquisition package for ion beam analysis

    International Nuclear Information System (INIS)

    Spizzirri, P.G.; Den Besten, J.L.; Jamieson, D.N.

    1999-01-01

    The analysis of crystalline materials using nuclear microprobe techniques is now commonplace. Channeling contrast microscopy (CCM) and Rutherford Backscattering (RBS) angular two-dimensional scans, which are used to study defects, strain, surface effects and the presence of impurity atoms in crystalline materials, can benefit from automation through computer control. Important criteria for a computer controlled instrument such as this are: suitable operating system (eg. Microsoft Windows), a graphical user interface (GUI), readily available components, cost effectiveness, ease of use, flexibility and scalability. While there are a number of effective RBS channeling angular scanning solutions in use throughout the microprobe community, few can provide this level of application abstraction. Recent trends in software and hardware development have seen the emergence of desktop/laptop personal computer-based virtual instruments. It has been said that the PC is now the most powerful and cost effective approach to building instruments because they can outperform 'blackbox' solutions in computing power, data transfer rates, memory, data storage, graphics, ease of use and familiarity. Other benefits stem from the availability of commercial-off-the-shelf (COTS) components (hardware) that can often provide complex functionality and third party analysis software that can extend the instrument's use beyond the vendor defined limits. This paper discusses a general purpose, data acquisition and motion control solution, G-Paq, based upon the National Instruments LabVIEW hardware and software development environment. Locally developed, this solution uses a minimum of customised components, is compatible with the principals of Good Laboratory Practice (GLP), is easy to use, has a graphical user interface and is flexible. While it has been developed for nuclear microprobe based channeling contrast microscopy using a specimen stage goniometer, its application to general motion control

  9. Spectral measurements of howardites in support of the interpretation of the Dawn VIR spectra at Vesta

    Science.gov (United States)

    De Angelis, S.; Ammannito, E.; Di Iorio, T.; De Sanctis, M.; Mittlefehldt, D.

    2014-07-01

    The howardites, eucrites, and diogenites constitute a suite of meteorite lithologies (HED) known to be related to asteroid Vesta [1]. Howardites are physical mixtures of eucrites and diogenites. Howardites are divided in two subtypes: regolithic howardites are actually linked to the true regolith, while fragmental howardites are simple polymict breccias [2]. Mapping of Vesta's surface, as obtained with data from Visible and Infrared mapping Spectrometer (VIR) on Dawn [3,4], showed that it is mainly howarditic, with few regions of diogenite-rich and eucrite-rich terrains [5, 6]. In order to map quantitatively the distribution of lithologic types on Vesta, we are carrying on a study of a set of well-characterized howardites [7]. Spectra were measured on sample powders sieved to 75 μ m in the laboratories of the Istituto di Astrofisica e Planetologia Spaziali (IAPS-INAF) in Rome (Italy) and Brown University, in Providence (USA). Here we report about the measurements done at IAPS-INAF. The spectra of 33 samples have been acquired with the S.LAB setup, consisting in the FieldSpec Pro spectrometer (range 0.35-2.5 μ m, spatial resolution 0.5 cm^2) coupled with a goniometer (incidence i=30°, emission e=0°) [8]. Some representative spectra of the measured howardites are shown in the figure. The spectra are characterized by the two broad Fe^{2+} absorption bands near 1 and 2 μ m (BI and BII) indicative of pyroxenes. Band parameters relative to BI and BII have been calculated using the algorithm developed to process VIR spectra [4]. This enables us to compare laboratory data directly with the VIR results. Other weaker absorptions also characterize some spectra: the 0.5 μ m feature (Mn^{2+} or Cr^{3+}) and the 1.2 μ m feature possibly due to Fe^{2+} in plagioclases. The PRA04401 sample is characterized by a pyroxene-carbonaceous matter mixture [7].

  10. Dependence on Solar Phase Angle and Grain Size of the Spectral Reflectance of the Railroad Valley Playa for GOSAT/GOSAT-2 Vicarious Calibration

    Science.gov (United States)

    Arai, T.; Matsunaga, T.

    2017-12-01

    GOSAT and the next generation GOSAT-2 satellites estimate the concentration of greenhouse gasses, and distribution of aerosol and cloud to observe solar light reflection and radiation from surface and atmosphere of the Earth. Precise information of the surface and the bidirectional reflectance distribution function (BRDF) are required for the estimation because the surface reflectance of solar light varies with the observation geometry and the surface condition. The purpose of this study is to search an appropriate BRDF model of the GOSAT calibration site (Railroad Valley playa). In 2017, JAXA, NIES, and NASA/OCO-2 teams collaboratively performed 9th vicarious experiments by the simultaneous observation with GOSAT, OCO-2, and ground-based equipment (Kuze et al., 2014) at the Railroad Valley from June 25 to 30. We performed the BRDF measurement to observe solar light reflection by varying with observed angles using a spectroradiometer (FieldSpec4, ASD Inc.) mounted on a one-axis goniometer. The surface sand was shifted to several sizes of grain (75, 125, 250, 500, and 1000 μm), which was measured for the limited area of 5mm diameter with a collimating lens (74-UV, OceanOptics). The BRDF parameters for the observed reflectance were determined by the least squares fitting with the free parameters of a single scattering albedo and an asymmetric factor (Hapke, 2012) for the ultraviolet to near infrared wavelength bands of GOSAT. The resulting value of the single scattering albedo increased with decreasing the grain size of the sands. The observed reflectance of the fine grain sands (below 250 μm) is not varied with observed phase angles (solar incident light - surface sand - detector) as a Lambertian reflectance, but the spectra of coarse grain sands (above 500 μm) are varied with the observation angles. Therefore, a priori information of the target surface such as grain size is required for the determination of the precise reflectance of the target.

  11. Cellular attachment and differentiation on titania nanotubes exposed to air- or nitrogen-based non-thermal atmospheric pressure plasma.

    Directory of Open Access Journals (Sweden)

    Hye Yeon Seo

    Full Text Available The surface topography and chemistry of titanium implants are important factors for successful osseointegration. However, chemical modification of an implant surface using currently available methods often results in the disruption of topographical features and the loss of beneficial effects during the shelf life of the implant. Therefore, the aim of this study was to apply the recently highlighted portable non-thermal atmospheric pressure plasma jet (NTAPPJ, elicited from one of two different gas sources (nitrogen and air, to TiO2 nanotube surfaces to further improve their osteogenic properties while preserving the topographical morphology. The surface treatment was performed before implantation to avoid age-related decay. The surface chemistry and morphology of the TiO2 nanotube surfaces before and after the NTAPPJ treatment were determined using a field-emission scanning electron microscope, a surface profiler, a contact angle goniometer, and an X-ray photoelectron spectroscope. The MC3T3-E1 cell viability, attachment and morphology were confirmed using calcein AM and ethidium homodimer-1 staining, and analysis of gene expression using rat mesenchymal stem cells was performed using a real-time reverse-transcription polymerase chain reaction. The results indicated that both portable nitrogen- and air-based NTAPPJ could be used on TiO2 nanotube surfaces easily and without topographical disruption. NTAPPJ resulted in a significant increase in the hydrophilicity of the surfaces as well as changes in the surface chemistry, which consequently increased the cell viability, attachment and differentiation compared with the control samples. The nitrogen-based NTAPPJ treatment group exhibited a higher osteogenic gene expression level than the air-based NTAPPJ treatment group due to the lower atomic percentage of carbon on the surface that resulted from treatment. It was concluded that NTAPPJ treatment of TiO2 nanotube surfaces results in an increase in

  12. Determination of global and local residual stresses in SOFC by X-ray diffraction

    International Nuclear Information System (INIS)

    Villanova, Julie; Sicardy, Olivier; Fortunier, Roland; Micha, Jean-Sebastien; Bleuet, Pierre

    2010-01-01

    Solid Oxide Fuel Cell (SOFC) is a high-performance electrochemical device for energy conversion. A single cell is composed of five layers made of different ceramic materials: anode support, anode functional layer, electrolyte, cathode functional layer and cathode. The mechanical integrity of the cell is a major issue during its lifetime, especially for the electrolyte layer. Damage of the cells is mainly due to the high operating temperature, the 'redox' behaviour of the anode and the brittleness of the involved materials. Since residual stresses are known to play a significant role in the damage evolution, it is important to determine them. For this purpose, residual stresses in an anode-supported planar SOFC were measured by X-ray diffraction. Firstly, macroscopic stresses in each phase of each layer were studied using the sin 2 ψ method on a laboratory X-ray goniometer at room temperature. This technique enables the calculation of residual stress of the material from the measurement of the crystal lattice deformation. The electrolyte has been found under bi-axial compressive stress of -920 MPa. Secondly, X-ray measurements controlling depth penetration were made in the electrolyte using grazing incidence method. The results show that the stress is not homogenous in the layer. The first five micrometers of the electrolyte have been found less constrained (-750 MPa) than the complete layer, suggesting a gradient of deformation in the electrolyte from the interface with the Anode Functional Layer to the free surface. Finally, local stress measurements were made on the electrolyte layer by X-ray synchrotron radiation that allows high accuracy measurement on the (sub-) micrometer scale. Polychromatic and monochromatic beams are used to determine the complete strain tensor from grain to grain in the electrolyte. First results confirm the macroscopic stress trend of the electrolyte. These X-ray techniques at different scales will contribute to a better understanding

  13. The initial safe range of motion of the ankle joint after three methods of internal fixation of simulated fractures of the medial malleolus.

    Science.gov (United States)

    Shimamura, Yoshio; Kaneko, Kazuo; Kume, Kazuhiko; Maeda, Mutsuhiro; Iwase, Hideaki

    2006-07-01

    Previous studies have demonstrated the safe passive range of ankle motion for inter-bone stiffness after internal fixation under load but there is a lack of information about the safe range of ankle motion for early rehabilitation in the absence of loading. The present study was designed to assess the effect of ankle movement on inter-bone displacement characteristics of medial malleolus fractures following three types of internal fixation to determine the safe range of motion. Five lower legs obtained during autopsy were used to assess three types of internal fixation (two with Kirschner-wires alone; two with Kirschner-wires plus tension band wiring; and, one with an AO/ASIF malleolar screw alone). Following a simulated fracture by sawing through the medial malleolus the displacement between the fractured bone ends was measured during a passive range of movement with continuous monitoring using omega (Omega) shaped transducers and a biaxial flexible goniometer. Statistical analysis was performed with repeated measures analysis of variance. Inter-bone displacement was not proportional to the magnitude of movement throughout the range of ankle motion as, when separation exceeded 25 microm, there was increasingly wide separation as plantar-flexion or dorsal-flexion was increased. There was no statistical significant difference between the small amount of inter-bone displacement observed with three types of fixation within the safe range of dorsal-flexion and plantar-flexion for early rehabilitation. However the inter-bone separation when fixation utilized two Kirschner-wires alone tended to be greater than when using the other two types of fixation during dorsal-flexion and eversion. The present study revealed a reproducible range of ankle motion for early rehabilitation which was estimated to be within the range of 20 degrees of dorsal-flexion and 10 degrees of plantar-flexion without eversion. Also, internal fixation with two Kirschner-wires alone does not seem to

  14. The influence of heterotopic ossification on functional status of hip joint following total hip arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Pohl, F.; Seufert, J.; Flentje, M.; Koelbl, O. [Wuerzburg Univ. (Germany). Dept. of Radiotherapy; Tauscher, A.; Springorum, H.W. [Caritas Krankenhaus Bad Mergentheim (Germany). Orthopedic Clinic; Lehmann, H. [Caritas Krankenhaus Bad Mergentheim (Germany). Inst. of Radiology

    2005-08-01

    Purpose: The functional failure induced by heterotopic ossification (HO) following total hip arthroplasty (THA) was analyzed and correlated to the radiologic failure. Patients and methods: From July 1997 to July 2001, 315 patients (345 hips) received THA indicated by a hypertrophic osteoarthritis of higher degree (Kellgren grade III, IV). All patients were irradiated prophylactically for prevention of HO on the evening before surgery with a 7-Gy single fraction. The patients' median age was 66.3 years. Radiologic failure was assessed by comparison of pre- and postoperative hip X-rays (immediately and 6 months after surgery). Analysis of radiographs was performed according to the Brooker Score. Clinical failure was appraised by measurement of passive range of motion (ROM) of the hip joint with a standard goniometer. The t-test was used for statistical analysis. Results: 281 patients (81.5%) did not develop HO. HO of Brooker grade I or II was found in 58 patients (16.8%). Six patients (1.7%) developed HO Brooker grade III or IV. There was a significant negative correlation between the degree of radiologic and clinical failure. ROM differed significantly between patients with HO Brooker grade 0, I, II and patients with HO Brooker grade III, IV. Comparing the pre- and postoperative ROM, all patients with Brooker grade 0, I and II showed a significant improvement of flexion, internal and external rotation, abduction and adduction movement. Patients with HO Brooker grade III and IV showed no improvement of ROM in the postoperative follow-up. Conclusion: The development of HO following THA influences the physical function of the hip joint dependent on the degree of ossification. HO of lower degree (Brooker I, II) does not influence the clinical outcome, whereas HO of higher degree (Brooker III, IV) reduces the function of hip arthroplasty. Therefore, the purpose of a prophylactic therapy must be to reduce HO of higher degree. (orig.)

  15. Effects of a home-exercise therapy programme on cervical and lumbar range of motion among nurses with neck and lower back pain: a quasi-experimental study.

    Science.gov (United States)

    Freimann, Tiina; Merisalu, Eda; Pääsuke, Mati

    2015-01-01

    Cervical and lumbar range of motion limitations are usually associated with musculoskeletal pain in the neck and lower back, and are a major health problem among nurses. Physical exercise has been evaluated as an effective intervention method for improving cervical and lumbar range of motion, and for preventing and reducing musculoskeletal pain. The purpose of this study was to investigate the effects of a home-exercise therapy programme on cervical and lumbar range of motion among intensive care unit nurses who had experienced mild to moderate musculoskeletal pain in the neck and or lower back during the previous six months. A quasi-experimental study was conducted among intensive care unit nurses at Tartu University Hospital (Estonia) between May and July 2011. Thirteen nurses who had suffered musculoskeletal pain episodes in the neck and or lower back during the previous six months underwent an 8-week home-exercise therapy programme. Eleven nurses without musculoskeletal pain formed a control group. Questions from the Nordic Musculoskeletal Questionnaire and the 11-point Visual Analogue Scale were used to select potential participants for the experimental group via an assessment of the prevalence and intensity of musculoskeletal pain. Cervical range of motion and lumbar range of motion in flexion, extension, lateral flexion and (cervical range of motion only) rotation were measured with a digital goniometer. A paired t-test was used to compare the measured parameters before and after the home-exercise therapy programme. A Student's t-test was used to analyse any differences between the experimental and control groups. After the home-exercise therapy, there was a significant increase (p cervical range of motion in flexion, extension, lateral flexion and rotation, and in lumbar range of motion in lateral flexion. Cervical range of motion in flexion was significantly higher (p cervical and lumbar range of motion among intensive care nurses. Further studies are

  16. Reflectance and Polarization Characteristics of Various Vegetation Types: an Advanced Experimental Approach using the FIGIFIGO Goniospectrometer

    Science.gov (United States)

    Gritsevich, M.; Peltoniemi, J.; Zubko, N.; Pisek, J.

    2016-12-01

    To reduce data acquired by Earth Observation projects and for collecting more accurate knowledge on the Earth, universe, and environment one needs to provide a set of reliable references carefully gathered by measuring various known, well characterized targets. We present an overview of the Finnish Geodetic Institute's field goniospectrometer, FIGIFIGO, and highlight its capabilities for spectropolarimetric measurements of various samples, both under actual field conditions and in the laboratory. The design concept of this custom made instrument has proven to have a number of advantages, such as a well designed, user friendly interface, a high level of automation, and an excellent adaptability to a wide range of weather conditions during field measurements. The instrument communicates via a control computer which has a simple user-friendly interface. It is battery powered and very portable, making it feasible to transport it by plane, car, boat, or sledge. The system includes a sky camera to detect the orientation of the goniometer and a pyranometer to monitor the synchronous illumination conditions. The instrument's mirror can be finely adjusted to apply small spatial corrections to the optical chain. The foreoptics is connected to an ASD FieldSpec Pro FR 350-2500 nm spectroradiometer by an optical fiber. A calcite Glan-Thompson prism is used as a polarizer, covering the full spectral range with better than 1% accuracy.FIGIFIGO has been used to measure the reflectance properties of hundreds of different targets, including various vegetation types. In particular, it has been shown that directional and polarization signals vary largely between different species, and provide information about the leaf surface and orientation. The measurement data are stored in the FGI's Reflectance Library and new specific measurements are made upon request. The potential use of the results from these measurements are diverse; including their use as ground truth references for Earth

  17. ACUTE EFFECTS OF TWO DIFFERENT WARM-UP PROTOCOLS ON FLEXIBILITY AND LOWER LIMB EXPLOSIVE PERFORMANCE IN MALE AND FEMALE HIGH LEVEL ATHLETES

    Directory of Open Access Journals (Sweden)

    Charilaos Tsolakis

    2012-12-01

    Full Text Available This study examined the effects of two different warm-up protocols on lower limb power and flexibility in high level athletes. Twenty international level fencers (10 males and 10 females performed two warm-up protocols that included 5-min light jogging and either short (15s or long (45s static stretching exercises for each of the main leg muscle groups (quadriceps, hamstrings and triceps surae, followed by either 3 sets of 3 (short stretching treatment, or 3 sets of 5 tuck jumps (long stretching treatment, in a randomized crossover design with one week between treatments. Hip joint flexion was measured with a Lafayette goniometer before and after the 5-min warm-up, after stretching and 8 min after the tuck jumps, while counter movement jump (CMJ performance was evaluated by an Ergojump contact platform, before and after the stretching treatment, as well as immediately after and 8 minutes after the tuck jumps. Three way ANOVA (condition, time, gender revealed significant time (p < 0.001 and gender (p < 0.001 main effects for hip joint flexion, with no interaction between factors. Flexibility increased by 6. 8 ± 1.1% (p < 0.01 after warm-up and by another 5.8 ± 1.6% (p < 0.01 after stretching, while it remained increased 8 min after the tuck jumps. Women had greater ROM compared with men at all time points (125 ± 8° vs. 94 ± 4° p<0.01 at baseline, but the pattern of change in hip flexibility was not different between genders. CMJ performance was greater in men compared with women at all time points (38.2 ± 1.9 cm vs. 29.8 ± 1.2 cm p < 0.01 at baseline, but the percentage of change CMJ performance was not different between genders. CMJ performance remained unchanged throughout the short stretching protocol, while it decreased by 5.5 ± 0.9% (p < 0.01 after stretching in the long stretching protocol However, 8 min after the tuck jumps, CMJ performance was not different from the baseline value (p = 0.075. In conclusion, lower limb power may

  18. Aging of oxygen and hydrogen plasma discharge treated a-C:H and ta-C coatings

    Energy Technology Data Exchange (ETDEWEB)

    Bachmann, Svenja [Physics of Surfaces, Institute of Materials Science, Technische Universität Darmstadt, Alarich-Weiss-Str. 16, 64287 Darmstadt (Germany); BMW Group, Hufelandstraße 4, 80788 Munich (Germany); Schulze, Marcus [Physics of Surfaces, Institute of Materials Science, Technische Universität Darmstadt, Alarich-Weiss-Str. 16, 64287 Darmstadt (Germany); Center of Smart Interfaces, Technische Universität Darmstadt, Alarich-Weiss-Str. 10, 64287 Darmstadt (Germany); Morasch, Jan [Institute of Materials Science, Technische Universität Darmstadt, Surface Science Division, Jovanka-Bonschits-Straße 2, 64287 Darmstadt (Germany); Hesse, Sabine [Physics of Surfaces, Institute of Materials Science, Technische Universität Darmstadt, Alarich-Weiss-Str. 16, 64287 Darmstadt (Germany); Center of Smart Interfaces, Technische Universität Darmstadt, Alarich-Weiss-Str. 10, 64287 Darmstadt (Germany); Hussein, Laith [Eduard-Zintl-Institut, Department of Chemistry, Technische Universität Darmstadt, Alarich-Weiss-Str. 12, 64287, Darmstadt (Germany); Krell, Lisa; Schnagl, Johann [BMW Group, Hufelandstraße 4, 80788 Munich (Germany); Stark, Robert W. [Physics of Surfaces, Institute of Materials Science, Technische Universität Darmstadt, Alarich-Weiss-Str. 16, 64287 Darmstadt (Germany); Center of Smart Interfaces, Technische Universität Darmstadt, Alarich-Weiss-Str. 10, 64287 Darmstadt (Germany); and others

    2016-05-15

    Highlights: • The water CA of O{sub 2} and H{sub 2} plasma treated a-C:H and ta-C changes from hydrophillic to hydrophobic on aging. • XPS study indicates that the decrease in surface energy of plasma treated a-C:H and ta-C could be due to adsorption of organic component from air. • The COFLFM of O{sub 2} and H{sub 2} plasma treated a-C:H and ta-C decreased upon aging. • The COF of glycerol lubricated ta-C showed no sign of change upon aging. - Abstract: Surface modification with gas plasma is an efficient and easy way to improve the surface energy and the tribological behavior of diamond-like carbon (DLC) coatings, e.g., in biomedical implants or as protective coatings. However, the long-term performance of the plasma treated DLC coatings is not fully clear. We thus studied the long-term stability of two kinds of DLC coatings, namely (a) hydrogenated amorphous carbon (a-C:H) and (b) tetrahedral amorphous carbon (ta-C) treated at different radio frequency (RF) power and time of oxygen (O{sub 2}) and hydrogen (H{sub 2}) plasma. Their surface properties, e.g. surface wettability, structure and tribological behavior, were studied at regular intervals for a period of two months using contact angle goniometer, Raman spectroscopy, X-ray photoelectron spectroscopy (XPS), lateral force microscopy (LFM) and ball on disc apparatus. The surface energy of both the coatings decreased upon aging. The higher the RF power and time of treatment, the higher was the hydrophobicity upon aging. XPS analysis showed that the increase in hydrophobicity could be due to adsorption of unavoidable volatile organic components in the atmosphere. The H{sub 2} plasma treated ta-C was capable of rearranging its structural bonds upon aging. The nano-friction measurements by LFM showed that the coefficient of friction of plasma treated a-C:H and ta-C decreased upon aging. The results indicate that the surface properties of plasma treated a‐C:H and ta‐C are not stable on long-term and are

  19. Efetividade da crioterapia após reconstrução do ligamento cruzado anterior Effectiveness of cryotherapy after anterior cruciate ligament reconstruction

    Directory of Open Access Journals (Sweden)

    Camila Dambros

    2012-01-01

    Full Text Available OBJETIVO: Avaliar a efetividade da crioterapia no pós-operatório imediato de reconstrução do ligamento cruzado anterior (LCA, em relação à redução da dor e melhora da amplitude de movimento (ADM do joelho. MÉTODOS: Trata-se do estudo piloto de um ensaio clínico prospectivo randomizado. Os pacientes (n=25 foram randomizados em dois grupos: (A Grupo Intervenção (n=10 que realizou um protocolo fisioterapêutico e fez uso do gelo por 20 minutos, duas vezes ao dia; e o Grupo (B Controle (n=9, que realizou o mesmo protocolo, duas vezes ao dia. A intensidade da dor foi avaliada pela Escala Análoga Visual e a ADM pela goniometria. RESULTADOS: O Grupo (A Intervenção obteve melhora absoluta e percentual quando comparado ao (B Controle, tanto para os parâmetros de dor, ADM de flexão e extensão do joelho. CONCLUSÃO: A crioterapia no pós-operatório imediato de reconstrução do LCA foi efetiva para melhorar a dor e a ADM do joelho. Nível de Evidência I, Estudo Clínico Randomizado.OBJECTIVE: The purpose of this study was to evaluate cryotherapy effectiveness in the immediate postoperative period of ACL reconstruction to improve pain and range of motion (ROM of the knee. METHODS: This is a pilot study of a prospective and randomized clinical trial. Patients (n=25 were divided into two groups: Intervention (A group (n=10: patients were submitted to an inpatient physical therapy protocol and received ice compress for 20 minutes, twice a day; Control (B group (n=9: patients had the same protocol, twice a day. The pain intensity was evaluated with the visual analogic scale (VAS and range of motion was measured with a goniometer. RESULTS: The Intervention (A group had important absolute and percentual improvement when compared with the Control (B group regarding measures of pain and knee flexion/extension ROM. CONCLUSION: Cryotherapy in the immediate postoperative period of ACL reconstruction was effective to improve pain and range of

  20. The efficacy of a HUBER exercise system mediated sensorimotor training protocol on proprioceptive system, lumbar movement control and quality of life in patients with chronic non-specific low back pain.

    Science.gov (United States)

    Letafatkar, Amir; Nazarzadeh, Maryam; Hadadnezhad, Malihe; Farivar, Niloufar

    2017-08-03

    There is a relation between deficits of the proprioceptive system and movement control dysfunction in patients with chronic low back pain (LBP) but, the exact mechanism of this relation is unknown. Exercise therapy has been recognized as an effective method for low back pain treatment. In spite of this, it is not clear which of the various exercise therapy programs lead to better results. Therefore, the present analyze the efficacy of a HUBER study aims to exercise system mediated sensorimotor training protocol on proprioceptive system, lumbar movement control (LMC) and quality of life (QOL) in patients with chronic non-specific LBP. Quasi-experimental study. 53 patients with chronic non-specific LBP (mean age 37.55 ± 6.67 years,and Body Mass Index (BMI) 22.4 ± 3.33) were selected by using Roland-Morris Disability Questionnaire (RMQ) and were assigned into two experimental (N= 27) and control groups (N= 26) The experimental group underwent a five-week (10 sessions) Sensorimotor training by using the Human Body Equalizer (HUBER) spine force under the supervision of an investigator. The movement control battery tests, the HUBER machine testing option, goniometer and visual analogue scale used for movement control, neuromuscular coordination, proprioception and LBP assessment respectively. The assessments were completed in pre-test and after five weeks. The paired and sample T tests were used for data analysis in SPSS program version 18 (Significance level were set at a P value pain scores of subjects with chronic non-specific LBP in the sensorimotor group (P= 0.001). In this study, only the short term effects of the sensorimotor training were examined. The results suggest that a sensorimotor training program causes significant improvement in patients with chronic non-specific LBP. Future research should be carried out with a larger sample size to examine the long term effects of the sensorimotor training program on treatment of patients with chronic non

  1. Deficits in glenohumeral passive range of motion increase risk of elbow injury in professional baseball pitchers: a prospective study.

    Science.gov (United States)

    Wilk, Kevin E; Macrina, Leonard C; Fleisig, Glenn S; Aune, Kyle T; Porterfield, Ron A; Harker, Paul; Evans, Timothy J; Andrews, James R

    2014-09-01

    Injuries to the elbow joint in baseball pitchers appear common. There appears to be a correlation between shoulder range of motion and elbow injuries. To prospectively determine whether decreased ROM of the throwing shoulder is correlated with the onset of elbow injuries in professional baseball pitchers. Cohort study; Level of evidence, 2. For 8 consecutive years (2005-2012), passive range of motion of both the throwing and nonthrowing shoulders of all major and minor league pitchers within a single professional baseball organization were measured by using a bubble goniometer during spring training. In total, 505 examinations were conducted on 296 pitchers. Glenohumeral external rotation and internal rotation were assessed in the supine position with the arm at 90° of abduction and in the plane of the scapula. The scapula was stabilized per methods previously established. Total rotation was defined as the sum of external rotation and internal rotation. Passive shoulder flexion was assessed with the subject supine and the scapula stabilized per methods previously established. Elbow injuries and days missed because of elbow injuries were assessed and recorded by the medical staff of the team. Throwing and nonthrowing shoulder measurements were compared by using Student t tests; 1-tailed Fisher exact tests were performed to identify significant associations between shoulder motion and elbow injury. Nominal logistic regression was performed to determine the odds of elbow injury. Significant differences were noted during side-to-side comparisons within subjects. There were 49 elbow injuries and 8 surgeries in 38 players, accounting for a total of 2551 days missed. Neither glenohumeral internal rotation deficit nor external rotation insufficiency was correlated with elbow injuries. Pitchers with deficits of >5° in total rotation in their throwing shoulders had a 2.6 times greater risk for injury. Pitchers with deficit of ≥5° in flexion of the throwing shoulder had

  2. PHYSICAL WORKLOAD AS A RISK FACTOR FOR SYMPTOMS IN THE NECK AND UPPER LIMBS: EXPOSURE ASSESSMENT AND ERGONOMIC INTERVENTION

    Directory of Open Access Journals (Sweden)

    Ritva Ketola

    2004-06-01

    Full Text Available The aims of this study were to investigate work related and individual factors as predictors of insident neck pain among video display unit (VDU workers, to assess the effects of an ergonomic intervention and education on musculoskeletal symptoms, and to study the repeatability and validity of an expert assessment method of VDU workstation ergonomics. A method to assess the risk factors for upper limb disorders was developed, and its validity and repeatability were studied. The annual incidence of neck pain was 34.4%. A poor physical work environment and placement of the keyboard were work-related factors increasing the risk of neck pain. Among the individual factors, female sex was a strong predictor. The randomized intervention study included questionnaire survey, a diary of discomfort, and ergonomic rating of the workstations. The subjects (n=124 were allocated into three groups. The intensive and the education groups had less musculoskeletal discomfort than the control group at the 2-month follow-up. After the intervention, the level of ergonomics was distinctly higher in the intensive ergonomic group than in the education or control group. Two experts in ergonomics analyzed and rated the ergonomics of workstations before and after intervention. The validity of the assessment method was rated against the technical measurements, assessment of tidiness and space, and work chair ergonomics. The intraclass correlation coefficient between ratings of the two experts was 0.74. Changes in the location of the input devises and the screen, as well as the values of tidiness and space and work chair ergonomics showed a significant association with the ratings of both experts. The method to assess the loads imposed on the upper limbs was validated against the expert observations from the video, continuous recordings of myoelectric activity of forearm muscles, and wrist posture, measured with goniometers. Inter-observer repeatability and validity were

  3. Biomechanical cadaveric comparison of patellar ligament suture protected by a steel cable versus a synthetic cable.

    Science.gov (United States)

    Bouget, P; Breque, C; Beranger, J S; Faure, J P; Khiami, F; Vendeuvre, T

    2017-12-01

    Purpose and hypothesis: Patellar ligament rupture is a rare disabling pathology requiring a surgical ligament suture protected by a frame. The gold standard is the steel cable, but its rigidity and the necessity of a surgical re-intervention for its removal render it unsatisfactory. The objective of this paper is to quantify the mechanical protection provided by the terylene® in comparison with steel. Twenty-four knees of 12 fresh frozen cadaveric subjects were divided into 2 homogeneous groups (terylene and steel) of 12 knees (mean age = 69.3 years). Proximal ligament repair was performed according to a three-tunnel transosseous reinsertion technique. Mechanical tests were performed in flexion to simulate movement of the knee. The interligament gap and the amplitude angulation of the knee were measured by a system of extensometer and optical goniometer. Mechanical analysis permitted calculation of flexion amplitude for a ligament gap of 1 and 2 mm taking as initial angle the adjusting angle of pretension of the protection frame. Study of deformations of frames was performed. Statistical analysis was performed with a Wilcoxon Mann Whitney test. There is no significant difference in protection of the ligament suture between the "terylene" and "steel" groups. Mean flexion amplitudes (mΔF) show no significant differences between the 2 groups for a distension of the suture of 1 mm (m ΔF terylene1 = 4.74 °; mΔF steel1 = 5.91°; p = 0.198) and 2 mm (mΔF terylene2 = 8.71°; mΔF steel2 = 10.41°; p = 0.114). Elastic deformation of terylene was significantly greater than that of steel (p = 0.0004). Suture protection of the patellar ligament by a terylene wire is not significantly different from that provided by steel frame. The elastic properties of terylene and absence of a need for re intervention to secure its removal lead us towards its use in acute ruptures of the patellar ligament. The main limits involve the properties of

  4. The Kinetics of Crystallization of Colloids and Proteins: A Light Scattering Study

    Science.gov (United States)

    McClymer, Jim

    2002-01-01

    Hard-sphere colloidal systems serve as model systems for aggregation, nucleation, crystallization and gelation as well as interesting systems in their own right.There is strong current interest in using colloidal systems to form photonic crystals. A major scientific thrust of NASA's microgravity research is the crystallization of proteins for structural determination. The crystallization of proteins is a complicated process that requires a great deal of trial and error experimentation. In spite of a great deal of work, "better" protein crystals cannot always be grown in microgravity and conditions for crystallization are not well understood. Crystallization of colloidal systems interacting as hard spheres and with an attractive potential induced by entropic forces have been studied in a series of static light scattering experiments. Additionally, aggregation of a protein as a function of pH has been studied using dynamic light scattering. For our experiments we used PMMA (polymethylacrylate) spherical particles interacting as hard spheres, with no attractive potential. These particles have a radius of 304 nanometers, a density of 1.22 gm/ml and an index of refraction of 1.52. A PMMA colloidal sample at a volume fraction of approximately 54% was index matched in a solution of cycloheptyl bromide (CHB) and cis-decalin. The sample is in a glass cylindrical vial that is placed in an ALV static and dynamic light scattering goniometer system. The vial is immersed in a toluene bath for index matching to minimize flair. Vigorous shaking melts any colloidal crystals initially present. The sample is illuminated with diverging laser light (632.8 nanometers) from a 4x microscope objective placed so that the beam is approximately 1 cm in diameter at the sample location. The sample is rotated about its long axis at approximately 3.5 revolutions per minute (highest speed) as the colloidal crystal system is non-ergodic. The scattered light is detected at various angles using the

  5. Comparison of 2D-3D Measurements of Hallux and First Ray Sagittal Motion in Patients With and Without Hallux Valgus.

    Science.gov (United States)

    Swanson, Jessica E; Stoltman, Matthew G; Oyen, Cheyenne R; Mohrbacher, Jessica A; Orandi, Atefeh; Olson, Jeff M; Glasoe, Ward M

    2016-02-01

    Clinicians base treatment decisions on measures of hallux and first ray motion in the management of first metatarsophalangeal joint disorders. Women account for a majority of the patients. This study assessed the reliability of a 2D approach for the measurements of sagittal motion, and compared the result to a Cardan (3D) angle criterion standard and evaluated how hallux valgus (bunion) deformity affected the comparisons. Twenty-nine women (controls n = 10; bunion n = 19) were examined using a retrospective repeated measures design. Weightbearing magnetic resonance (MR) images were acquired to replicate the position of the foot during the stance phase of gait. The images were reconstructed into virtual bone models using computer processes, whereby measures of hallux and first ray motion were represented by 2D and 3D methods of measurement. An examiner measured 2D motion on the image data sets using a goniometer, and reliability was assessed. The 3D Cardan angle result was derived from a matrix calculation. The 2D-3D comparison of measurements was evaluated with an analysis of variance (ANOVA) model across gait conditions, run separate for groups. The 2D measurement was reliable (ICC ≥ 0.98, SEM ≤ 0.89 degrees). There was no method-by-condition interaction (F ≤ 1.37, P ≥ .25) between variables. No significant difference was detected between the 2D-3D measurements in the control group (F ≤ 1.24, P ≥ .30), but the measurements were statistically different (F ≥ 4.46, P ≤ .049) in the bunion group. This study described a reliable 2D approach for measuring hallux and first ray sagittal motion from weightbearing images. The 2D measurements were comparable to a Cardan angle component motion result in controls, but not in women with bunion. Joint motion measurements may augment clinical decision making. These results suggest that a 2D image-based approach may be adequate to estimate hallux and first ray sagittal motion, although bunion deformity creates out

  6. A comparison of two manual physical therapy approaches and electrotherapy modalities for patients with knee osteoarthritis: A randomized three arm clinical trial.

    Science.gov (United States)

    Kaya Mutlu, Ebru; Ercin, Ersin; Razak Ozdıncler, Arzu; Ones, Nadir

    2018-08-01

    A broad spectrum of physical therapy exercise programs provides symptom relief and functional benefit for patients with knee OA. Manual physical therapy, including tailored exercise programs provide relatively higher level benefit that persists to one year. It is currently unknown if there are important differences in the effects of different manual physical therapy techniques for patients with knee OA and there are virtually no studies comparing manual physical therapy and electrotherapy modalities. The aim of the study was to compare long-term results between three treatment groups (mobilization with movements [MWMs], passive joint mobilization [PJM], and electrotherapy) to determine which treatment is most effective in patients with knee OA. A single-blind randomized clinical trial with parallel design was conducted in patients with knee OA. Seventy-two consecutive patients (mean age 56.11 ± 6.80 years) with bilateral knee OA were randomly assigned to one of three treatment groups: MWMs, PJM, and electrotherapy. All groups performed an exercise program and received 12 sessions. The primary outcome measures of the functional assessment were the Western Ontario and McMaster Universities Osteoarthritis index (WOMAC) and Aggregated Locomotor Function (ALF) test scores. The secondary outcome measures were pain level, measured using a pressure algometer and a visual analogue scale (VAS), range of motion (ROM), measured using a digital goniometer, and muscle strength, evaluated with a handheld dynamometer. Patients were assessed before treatment, after treatment and after 1 year of follow-up. Patients receiving the manual physical therapy interventions consisting of either MWM or PJM demonstrated a greater decrease in VAS scores at rest, during functional activities, and during the night compared to those in the electrotherapy group from baseline to after the treatment (p < 0.05). This improvement continued at the 1-year follow-up (p < 0.05). The MWMs and PJM

  7. Propriocepção de joelho em jovens e idosas praticantes de exercícios físicos Knee proprioception in physically active young and elderly women

    Directory of Open Access Journals (Sweden)

    Danielle Ledur Antes

    2009-12-01

    Full Text Available A propriocepção é um mecanismo neuromuscular que descreve informações neurais originadas nas articulações, músculos e tendões. Este estudo verificou a propriocepção de joelho em jovens e idosas praticantes de exercícios físicos. Participaram do estudo 44 mulheres - 22 idosas (média de idade 69,4 anos e 22 jovens, idade média 22,5. A propriocepção foi avaliada pelo senso de posição articular, sendo a participante solicitada a reposicionar o membro inferior dominante previamente estendido ou flexionado pelo avaliador. Os ângulos de flexão e extensão do joelho foram sorteado, utilizando-se nos testes um goniômetro fixo à perna da participante. Considerou-se como variável o valor absoluto do erro, isto é, a diferença em graus entre o ângulo proposto e o ângulo reproduzido pela avaliada. Os dados foram tratados estatisticamente, com nível de significância de pProprioception is a neuromuscular mechanism that describes neural information originating from the joints, muscles and tendons. This study aimed at verifying proprioception of the knee in young and elderly women with regular physical activity. Subjects were 44 women - 22 elderly, mean age 69.4 years old, and 22 young women, mean age 22.5 years old. Proprioception was assessed by the sense of joint position, the subject being asked to reposition the dominant leg previously flexed or extended by the examiner. Flexion and extension angles were randomized, and measured by means of a goniometer attached to the subject's leg. The variable considered was the absolute error value, that is, the difference between the angle proposed and the angle shown by the subject. Data were statistically analysed and significance level set at p<0.05. The elderly group mean error was 6.75±3.01º, and the young ladies', 5.73±4.24°; no significant difference (p=0.249 was found between the groups. Hence, although proprioception is known to decline with age, the elderly group showed

  8. Recent advances in the application of electron tomography to materials chemistry.

    Science.gov (United States)

    Leary, Rowan; Midgley, Paul A; Thomas, John Meurig

    2012-10-16

    Nowadays, tomography plays a central role in pureand applied science, in medicine, and in many branches of engineering and technology. It entails reconstructing the three-dimensional (3D) structure of an object from a tilt series of two-dimensional (2D) images. Its origin goes back to 1917, when Radon showed mathematically how a series of 2D projection images could be converted to the 3D structural one. Tomographic X-ray and positron scanning for 3D medical imaging, with a resolution of ∼1 mm, is now ubiquitous in major hospitals. Electron tomography, a relatively new chemical tool, with a resolution of ∼1 nm, has been recently adopted by materials chemists as an invaluable aid for the 3D study of the morphologies, spatially-discriminating chemical compositions, and defect properties of nanostructured materials. In this Account, we review the advances that have been made in facilitating the recording of the required series of 2D electron microscopic images and the subsequent process of 3D reconstruction of specimens that are vulnerable, to a greater or lesser degree, to electron beam damage. We describe how high-fidelity 3D tomograms may be obtained from relatively few 2D images by incorporating prior structural knowledge into the reconstruction process. In particular, we highlight the vital role of compressed sensing, a recently developed procedure well-known to information theorists that exploits ideas of image compression and "sparsity" (that the important image information can be captured in a reduced data set). We also touch upon another promising approach, "discrete" tomography, which builds into the reconstruction process a prior assumption that the object can be described in discrete terms, such as the number of constituent materials and their expected densities. Other advances made recently that we outline, such as the availability of aberration-corrected electron microscopes, electron wavelength monochromators, and sophisticated specimen goniometers

  9. X-ray diffraction of modified and graft polymerised cellulose fibres

    International Nuclear Information System (INIS)

    Ouajai, S.; Hodzic, A.; Shanks, R.A.

    2003-01-01

    Full text: The aim of this research is to modify natural cellulosic fibres in order to improve and increase consistency of their performance in biodegradable materials. Fibre modification consisted of solvent extraction and NaOH treatment in order to remove wax and lignin before grafting with acrylonitrile monomer. The mechanical properties, moisture regain and pore structures were investigated. Finally an analysis of crystalline structure was performed using quantitative FTIR, WAXD and SAXS to assess the relationship between structure and properties after modification. Materials: Hemp (Cannabis sativa), Australian Hemp Resource and Manufacture (AHRM) and Flax (Durafibre Grade 1, 95 % purity), Cargill, Canada. Pretreatments: Dewaxing by acetone extraction, alkalisation with NaOH solutions, grafting reaction with acrylonitrile and AIBN thermal initiator after absorption of the monomer. Surface and pore structure analysis using Micromeritics ASAP 2000 BET adsorption instrument, FTIR Perkin-Elmer 2000 spectrometer, wide angle X-ray diffraction, Bruker AXS D8, Ni-filtered CuKα radiation (λ 0.1542 nm) at 40 kV and 35 mA. The diffractograms were recorded from 5 to 60 deg of 2 θ (Bragg angle) by a goniometer with a scintillation counter, scanning speed 0.02 deg/s and sampling rate of 2 data/s. The 2-D small-angle X-ray data was collected by Bruker AXS, Nanostar from 0.5 to 14 deg of 2θ (Bragg angle). Typical exposure time was 5 hours at 40 kV and 35 mA. Single fibre mechanical properties were carried out on a Rheometric DMTA IV at 0.03 mm/min. Moisture regain measurements were performed gravimetrically. The crystalline structure of the fibres were changed from cellulose I to cellulose II after NaOH treatment. The intensity of the 1431 cm -1 band was reduced while the 898 cm -1 band was increased and shifted to 893 cm -1 with an increase of NaOH concentration. X-ray diffractograms of flax and hemp were obtained for each treatment. Untreated fibre shows the

  10. Reliability and concurrent validity of the iPhone® Compass application to measure thoracic rotation range of motion (ROM) in healthy participants

    Science.gov (United States)

    Schram, Ben; Cox, Alistair J.; Anderson, Sarah L.; Keogh, Justin

    2018-01-01

    Background Several water-based sports (swimming, surfing and stand up paddle boarding) require adequate thoracic mobility (specifically rotation) in order to perform the appropriate activity requirements. The measurement of thoracic spine rotation is problematic for clinicians due to a lack of convenient and reliable measurement techniques. More recently, smartphones have been used to quantify movement in various joints in the body; however, there appears to be a paucity of research using smartphones to assess thoracic spine movement. Therefore, the aim of this study is to determine the reliability (intra and inter rater) and validity of the iPhone® app (Compass) when assessing thoracic spine rotation ROM in healthy individuals. Methods A total of thirty participants were recruited for this study. Thoracic spine rotation ROM was measured using both the current clinical gold standard, a universal goniometer (UG) and the Smart Phone Compass app. Intra-rater and inter-rater reliability was determined with a Intraclass Correlation Coefficient (ICC) and associated 95% confidence intervals (CI). Validation of the Compass app in comparison to the UG was measured using Pearson’s correlation coefficient and levels of agreement were identified with Bland–Altman plots and 95% limits of agreement. Results Both the UG and Compass app measurements both had excellent reproducibility for intra-rater (ICC 0.94–0.98) and inter-rater reliability (ICC 0.72–0.89). However, the Compass app measurements had higher intra-rater reliability (ICC = 0.96 − 0.98; 95% CI [0.93–0.99]; vs. ICC = 0.94 − 0.98; 95% CI [0.88–0.99]) and inter-rater reliability (ICC = 0.87 − 0.89; 95% CI [0.74–0.95] vs. ICC = 0.72 − 0.82; 95% CI [0.21–0.94]). A strong and significant correlation was found between the UG and the Compass app, demonstrating good concurrent validity (r = 0.835, p reliable tool for measuring thoracic spine rotation which produces greater

  11. Stretching After Heat But Not After Cold Decreases Contractures After Spinal Cord Injury in Rats.

    Science.gov (United States)

    Iwasawa, Hiroyuki; Nomura, Masato; Sakitani, Naoyoshi; Watanabe, Kosuke; Watanabe, Daichi; Moriyama, Hideki

    2016-12-01

    Contractures are a prevalent and potentially severe complication in patients with neurologic disorders. Although heat, cold, and stretching are commonly used for treatment of contractures and/or spasticity (the cause of many contractures), the sequential effects of these modalities remain unclear. Using an established rat model with spinal cord injury with knee flexion contracture, we sought to determine what combination of heat or cold before stretching is the most effective for treatment of contractures derived from spastic paralyses and investigated which treatment leads to the best (1) improvement in the loss of ROM; (2) restoration of deterioration in the muscular and articular factors responsible for contractures; and (3) amelioration of histopathologic features such as muscular fibrosis in biceps femoris and shortening of the joint capsule. Forty-two adolescent male Wistar rats were used. After spasticity developed at 2 weeks postinjury, each animal with spinal cord injury underwent the treatment protocol daily for 1 week. Knee extension ROM was measured with a goniometer by two examiners blinded to each other's scores. The muscular and articular factors contributing to contractures were calculated by measuring ROM before and after the myotomies. We quantitatively measured the muscular fibrosis and the synovial intima length, and observed the distribution of collagen of skeletal muscle. The results were confirmed by a blinded observer. The ROM of heat alone (34° ± 1°) and cold alone (34° ± 2°) rats were not different with the numbers available from that of rats with spinal cord injury (35° ± 2°) (p = 0.92 and 0.89, respectively). Stretching after heat (24° ± 1°) was more effective than stretching alone (27° ± 3°) at increasing ROM (p contractures. Although quantification of muscular fibrosis in the rats with spinal cord injury (11% ± 1%) was higher than that of controls (9% ± 0.4%) (p = 0.01), no difference was found between spinal cord

  12. The contact angle of wetting of the solid phase of soil before and after chemical modification

    Directory of Open Access Journals (Sweden)

    Tyugai Zemfira

    2015-07-01

    Full Text Available Wettability of soil affects a wide variety of processes including infiltration, preferential flow and surface runoff. Wettability of surface is usually expressed in terms of contact angle (CA measurement. If the CA between liquid and solid surface is less than 90°, the surface is called hydrophilic, otherwise the surface is called hydrophobic. If the CA of water droplet on hydrophilic surface is in a range of 0-30° this surface is called superhydrophilic. In case of superhydrophobic surfaces the CA exceeds 150° that means that these surfaces are extremely difficult to wet. CA of wetting of mineral soil particles depends on the overlying organic and iron compounds. The object of study is a sample of the humus-accumulative horizon of typical chernozem (Kursk, Russia and two samples (horizons A1, B2 of red ferrallitic soils (Fr. Norfolk, NE Oceania. The soil samples were analyzed for organic carbon, forms of non-silicate iron and hydrophobic-hydrophilic composition of humic substances. CA of wetting was determined in the intact samples and after removal of organic matter (H2O2 treatment, amorphous and crystallized forms of iron. Static contact angles were determined with the sessile drop method using a digital goniometer (Drop Shape Analysis System, DSA100, Krüss GmbH, Hamburg, Germany. The contact angle was calculated by the Young–Laplace method (fitting of Young–Laplace equation to the drop shape. The measurements were repeated 10-15 times for every sample. Oxidation of organic matter (H2O2 treatment causes an increase in the values of CA of wetting (in chernozem from 9.3 to 28,0-29.5º, in ferrallitic soil from 18.0 − 27.3 to 22.4 − 33.4º. CA remained constant for chernozem and slightly decreased in the case of ferrallitic soil, when the removal of amorphous and crystallized forms of iron was performed on samples pretreated with H2O2. CA increase occurs after successive removal of nonsilicate forms of iron from soil samples of

  13. Comparison of the effect of low-power laser with therapeutic ultrasound on the treatment of rotator cuff tendonitis

    Directory of Open Access Journals (Sweden)

    asghar Akbari

    2009-01-01

    Full Text Available Akbari A1 1. Assistant Professor, Department of Physiotherapy, Faculty of Medicine, Zahedan University of Medical Sciences Abstract Background: Shoulder pain is the third most prevalent cause of musculoskeletal disorder after low back and cervical pains. Most of the shoulder symptoms are attributed to the rotator cuff. The objective of this study was to compare the effects of low-power laser therapy with ultrasound therapy on the patients with rotator cuff tendonitis. Materials and methods: This clinical trial was performed in Zahedan university of medical sciences in 2006. Thirty patients with rotator cuff tendonitis were randomly assigned to either a low-power laser therapy group (15 patients or an ultrasound therapy group (15 patients. Strength (kg of shoulder abductor, and internal and external rotator muscles, as well as range (degree of shoulder abduction, and internal and external rotation were measured before and after intervention using hand-held dynamometer and goniometer respectively. The pain was evaluated using the visual analogue scale. In the laser group, a low-level Ga-As laser was applied with a 100 mw point probe (average power, wave length of 905 nm, pulse duration of 200 ns, 6 J/cm2 dosage, 5 KHz frequency, and lasting 3 minutes. The ultrasound treatment was applied with a power of 1 W/cm2, a frequency of 1 MHz, pulse mode of 1:4, and lasting 10 minutes on each occasion. The treatment was carried out 3 times weekly for 10 days. The data were analyzed using independent sample t-test and paired t-test. Results: The pain in the laser group was significantly decreased from 6.06±1.6 to 5±1.3 in abduction, from 5.3±1.5 to 4.7±1.3 in internal rotation, and from 5.06±1.4 to 4.3±1.44 in external rotation (p0.05. A significant improvement after treatment was observed in the laser group in measures of shoulder abductor, internal rotator and external rotator muscles strength compared to those of the ultrasound therapy group (p<0

  14. Process-Structure-Property Relationship in Magnesium-Based Biodegradable Alloy for Biomedical Applications

    Science.gov (United States)

    Trivedi, Pramanshu

    Magnesium alloys are considered to be the next generation of biomaterials because of their ability to degrade in the physiological environment. We elucidate here the impact of multiaxial forging of Mg-2Zn-2Gd alloy on grain refinement to sub-micron regime and relate the structure to mechanical properties and biological functionality. As-cast and annealed samples were multiaxial forged (MAF) for a total number of two passes with a true strain of 2/pass. Considering that the microstructure governs the biological response of materials, we studied the constituents of the microstructure in conjunction with the mechanical behavior. The antimicrobial behavior in a Mg-2Zn-2Gd alloy with different grain size in the range of 44 microm to 710 nm was studied by seeding. Surface energy and contact angle measurements using goniometer and wettability were assessed with water, SBF, n-Hexane, and DMEM. The structure-property relationship in Mg-2Zn-2Gd alloy to maintaining mechanical integrity during degradation was studied by seeding Escherichia coli ( E. coli). Furthermore, we studied the effect of degradation behavior in the presence and absence of cells. This was followed by the study of bioactivity in terms of phases present on the surface and degradation products in simulated body fluid (SBF). Magnesium coated with apatite using a biomimetic approach were placed in a 24-well culture plate with alpha-MEM media and the degradation behavior was studied in the absence and presence of cells (seeding density: 10,000 cells/cm2). The change in pH was monitored at regular intervals. Cell attachment was studied by seeding the cells for 4h and cell viability was studied by seeding the cells for up to 1, 3, and 7 days. The study underscores that the fine-grained alloys exhibited superior mechanical properties, antimicrobial resistance, and cell attachment. The degradation rate was also least for fine-grained alloy. The higher surface energy of ultrafine-grained Mg-2Zn-2Gd alloy led to the

  15. CHARACTERISTICS OF MAXIMUM PERFORMANCE OF PEDALING EXERCISE IN RECUMBENT AND SUPINE POSITIONS

    Directory of Open Access Journals (Sweden)

    Morimasa Kato

    2011-09-01

    Full Text Available To determine the characteristics of maximum pedaling performance in the recumbent and supine positions, maximum isokinetic leg muscle strength was measured in eight healthy male subjects during pedaling at three velocities (300°/s, 480°/s, and 660°/s, and maximum incremental tests were performed for each position. The maximum isokinetic muscle strength in the recumbent position was 210.0 ± 29.2 Nm at 300°/s, 158.4 ± 19.8 Nm at 480°/s, and 110.6 ± 13.2 at 660°/s. In contrast, the muscle strength in the supine position was 229.3 ± 36.7 Nm at 300°/s, 180. 7 ± 20.3 Nm at 480°/s, and 129.6 ± 14.0 Nm at 660°/s. Thus, the maximum isokinetic muscle strength showed significantly higher values in the supine position than in the recumbent position at all angular velocities. The knee and hip joint angles were measured at peak torque using a goniometer; the knee joint angle was not significantly different between both positions, whereas the hip joint angle was greater in the supine position than in the recumbent position (Supine position: 137.3 ± 9. 33 degree at 300°/s, 140.0 ± 11.13 degrees at 480°/s, and 141.0 ± 9.61 degrees at 660°/s. Recumbent position: 99.5 ± 12.21 degrees at 300°/s, 101.6 ± 12.29 degrees at 480°/s, and 105.8 ± 14.28 degrees at 660°/s. Peak oxygen uptake was higher in the recumbent position (50.3 ± 4.43 ml·kg-1·min-1 than in the supine position (48.7 ± 5.10 ml·kg-1·min-1. At maximum exertion, the heart rate and whole-body rate of perceived exertion (RPE were unaffected by position, but leg muscle RPE was higher in the supine position (19.5 ± 0.53 than in the recumbent position (18.8 ± 0.71. These results suggest that the supine position is more suitable for muscle strength exertion than the recumbent position, and this may be due to different hip joint angles between the positions. On the contrary, the endurance capacity was higher in the recumbent position than in the supine position. Since leg muscle

  16. Survey of boron detectors for thermal neutrons operating in the non proportional regime; Etude de detecteurs a bore pour neutrons thermiques fonctionnant en regime non proportionnel

    Energy Technology Data Exchange (ETDEWEB)

    Vacarie, J [Commissariat a l' Energie Atomique, 38 - Grenoble (France). Centre d' Etudes Nucleaires

    1968-07-01

    In gas counters, the alternative of directly detecting (i.e. without using the phenomenon of multiplication the charges ionized by the reaction {sup 10}B (n,{alpha}){sup 7}Li, offers many advantages as to the conception of such a detector. After examining the ionization phenomenon and deducing the characteristics of low-noise amplifiers, various prototypes are studied. - The D.I.N. 5/4, intended for fast neutrons detector, grants leave to have good isotropic proprieties thanks to its geometry and good sensitivity imputable to the BF{sub 3} filling pressure of 1 atm. - A flat counter (D.E.H. type), with plane and parallel electrodes, grants leave to work out a low height of influence, soil moisture measurer. The confrontation between various filling pressures (0.5, 1, 2, 3 atm.) points out the importance of attachment in BF{sub 3}. - Thanks to neutronic diffraction counter (C.D.N. 2 type) filled under 2 atm and parallelepiped, one can considerably reduce the weight of the goniometer protection, and lightly increase its sensitivity. - The results given by the experimental boron coating device have allowed to build a boron coating counter to be used in current collection. (author) [French] Dans les compteurs a gaz, la possibilite de detecter directement (c'est-a-dire sans utiliser le phenomene de multiplication) les charges ionisees lors de la reaction {sup 10}B (n,{alpha}){sup 7}Li offre de nombreux avantages pour la conception de detecteurs a bore. Apres avoir examine les phenomenes d'ionisation et en avoir deduit les caracteristiques de la chaine d'amplification faible-bruit, on etudie les differents prototypes developpes. - Le D.I.N. 5/4 destine a une sonde de neutrons rapides, permet d'avoir une bonne isotropie grace a sa geometrie et une bonne sensibilite due a sa pression de remplissage de 1 atm. en BF{sub 3}. - Un compteur plat (type D.E.H.) a electrodes planes et paralleles permet de realiser un humidimetre a faible hauteur d'influence. La comparaison de

  17. Proton Beam Writing

    International Nuclear Information System (INIS)

    Rajta, I.; Szilasi, S.Z.; Csige, I.; Baradacs, E.

    2005-01-01

    flow channel, which were also implanted at the same irradiation. During the porous Si formation we developed the sample 6-8 μm deeper than the implanting ion range damaged the crystal. Due to the isotropic nature of the porous Si etching, the thick sidewall blocks are still connected to the crystal while the thin membranes detached from the bottom, and they are only connected to one of the sidewalls. The other construction utilized the goniometer facility mounted on the microbeam chamber, we implanted the samples at 40 degrees tilt, and developed the samples not as deep as the ion range. This way both the sidewalls and the membranes are attached to the bottom of the sample. The SEM images of the samples showed that both of these types of valves can be actively working, however, the thickness of the moving membrane requires extremely large force according to the fluidic tests. In order to achieve a successful demonstration of the functionality, the membrane rigidity should be reduced by decreasing the wall thickness. Reduction of optimal fluence by CO 2 treatment after exposure and vacuum effects in proton beam micromachining of CR-39 CR-39 has been shown to be a suitable material as a thick resist for Proton Beam Writing [5]. These samples are normally used to detect single alpha particles in normal air conditions. However, to use this material as proton or alpha micromachinable resists, we need to irradiate the samples in vacuum. In this work, we investigated the effects of vacuum on the micromachinable properties of CR-39. Our investigations proved that there were no drawbacks of the vacuum storage of the samples, so we concluded that CR-39 is a suitable material as a PBM resist in this respect, too. Another part of the current work concentrated on the effect of post-irradiaton CO 2 treatment of the samples. Such a treatment increased the radiation sensitivity of CR-39, i.e. decreased the necessary optimal ion fluence. We have found that approximately 60% of fluence

  18. The influence of gestational age and birth weight in the clinical assesment of the muscle tone of healthy term and preterm newborns A influência da idade gestacional e do peso ao nascimento na avaliação clínica do tono muscular de recém nascidos a termo e prematuros hígidos

    Directory of Open Access Journals (Sweden)

    Edla S. da Silva

    2005-12-01

    Full Text Available OBJECTIVE: To evaluate the influence of gestational age (GA and birth weight (BW in the clinical assessment of the muscle tone of healthy term and preterm newborns. METHOD: Cross sectional study. The muscle tone of healthy 42 preterm and 47 term newborns was quantified and measured with a goniometer (an instrument for measuring angles respectively between 7th-14th day of life and 24-48 hours of life. Newborns were grouped according to GA and BW and evaluated at fixed time intervals by one examiner. Preterm newborns were matched to term at 40 weeks postconceptional age (PCA. RESULTS: The evolution of muscle tone in the preterm occurred gradually, following PCA, independent of birth weight. Preterm newborns had lower scores in all muscle tone indicators when compared to term at the first assessment. Differences were observed among preterm small for GA and adequate to GA for the indicator heel to ear (pOBJETIVO: Verificar a influência da idade gestacional (IG e do peso ao nascimento (PN na avaliação do tono muscular de recém nascidos (RN a termo e prematuros hígidos. MÉTODO: Estudo transversal. O tono muscular de 42 RN prematuros e 47 termo foi quantificado e mensurado com goniômetro (instrumento para medir ângulos, respectivamente entre 7-14 dias de vida e 24-48 horas de vida. Os RN foram agrupados de acordo com IG e PN, sendo avaliados em intervalos fixos. RN prematuros foram comparados aos a termo na 40ª semana de idade concepcional (IC. RESULTADOS: A evolução do tono muscular nos RN prematuros ocorreu de forma gradual de acordo com IC e independente do PN. RN prematuros, na primeira avaliação apresentaram escores de tono muscular inferiores aos de RN a termo em todos os indicadores. Foram observadas diferenças entre RN prematuros pequenos e adequados para a IG em relação ao indicador calcanhar-orelha (p<0,001. O pareamento dos grupos na 40ª semana de IC mostra, exceto pela postura, diferença significativa entre os grupos (p< 0

  19. X-ray diffraction of modified and graft polymerised cellulose fibres

    Energy Technology Data Exchange (ETDEWEB)

    Ouajai, S; Hodzic, A; Shanks, R A [RMIT University, Melbourne, VIC (Australia). Applied Chemistry

    2003-07-01

    Full text: The aim of this research is to modify natural cellulosic fibres in order to improve and increase consistency of their performance in biodegradable materials. Fibre modification consisted of solvent extraction and NaOH treatment in order to remove wax and lignin before grafting with acrylonitrile monomer. The mechanical properties, moisture regain and pore structures were investigated. Finally an analysis of crystalline structure was performed using quantitative FTIR, WAXD and SAXS to assess the relationship between structure and properties after modification. Materials: Hemp (Cannabis sativa), Australian Hemp Resource and Manufacture (AHRM) and Flax (Durafibre Grade 1, 95 % purity), Cargill, Canada. Pretreatments: Dewaxing by acetone extraction, alkalisation with NaOH solutions, grafting reaction with acrylonitrile and AIBN thermal initiator after absorption of the monomer. Surface and pore structure analysis using Micromeritics ASAP 2000 BET adsorption instrument, FTIR Perkin-Elmer 2000 spectrometer, wide angle X-ray diffraction, Bruker AXS D8, Ni-filtered CuK{alpha} radiation ({lambda} 0.1542 nm) at 40 kV and 35 mA. The diffractograms were recorded from 5 to 60 deg of 2 {theta} (Bragg angle) by a goniometer with a scintillation counter, scanning speed 0.02 deg/s and sampling rate of 2 data/s. The 2-D small-angle X-ray data was collected by Bruker AXS, Nanostar from 0.5 to 14 deg of 2{theta} (Bragg angle). Typical exposure time was 5 hours at 40 kV and 35 mA. Single fibre mechanical properties were carried out on a Rheometric DMTA IV at 0.03 mm/min. Moisture regain measurements were performed gravimetrically. The crystalline structure of the fibres were changed from cellulose I to cellulose II after NaOH treatment. The intensity of the 1431 cm{sup -1} band was reduced while the 898 cm{sup -1} band was increased and shifted to 893 cm{sup -1} with an increase of NaOH concentration. X-ray diffractograms of flax and hemp were obtained for each treatment

  20. Reliability and concurrent validity of the iPhone® Compass application to measure thoracic rotation range of motion (ROM in healthy participants

    Directory of Open Access Journals (Sweden)

    James Furness

    2018-03-01

    Full Text Available Background Several water-based sports (swimming, surfing and stand up paddle boarding require adequate thoracic mobility (specifically rotation in order to perform the appropriate activity requirements. The measurement of thoracic spine rotation is problematic for clinicians due to a lack of convenient and reliable measurement techniques. More recently, smartphones have been used to quantify movement in various joints in the body; however, there appears to be a paucity of research using smartphones to assess thoracic spine movement. Therefore, the aim of this study is to determine the reliability (intra and inter rater and validity of the iPhone® app (Compass when assessing thoracic spine rotation ROM in healthy individuals. Methods A total of thirty participants were recruited for this study. Thoracic spine rotation ROM was measured using both the current clinical gold standard, a universal goniometer (UG and the Smart Phone Compass app. Intra-rater and inter-rater reliability was determined with a Intraclass Correlation Coefficient (ICC and associated 95% confidence intervals (CI. Validation of the Compass app in comparison to the UG was measured using Pearson’s correlation coefficient and levels of agreement were identified with Bland–Altman plots and 95% limits of agreement. Results Both the UG and Compass app measurements both had excellent reproducibility for intra-rater (ICC 0.94–0.98 and inter-rater reliability (ICC 0.72–0.89. However, the Compass app measurements had higher intra-rater reliability (ICC = 0.96 − 0.98; 95% CI [0.93–0.99]; vs. ICC = 0.94 − 0.98; 95% CI [0.88–0.99] and inter-rater reliability (ICC = 0.87 − 0.89; 95% CI [0.74–0.95] vs. ICC = 0.72 − 0.82; 95% CI [0.21–0.94]. A strong and significant correlation was found between the UG and the Compass app, demonstrating good concurrent validity (r = 0.835, p < 0.001. Levels of agreement between the two devices were 24.8° (LoA –9

  1. Remote sensing analysis for fault-zones detection in the Central Andean Plateau (Catamarca, Argentina)

    Science.gov (United States)

    Traforti, Anna; Massironi, Matteo; Zampieri, Dario; Carli, Cristian

    2015-04-01

    Remote sensing techniques have been extensively used to detect the structural framework of investigated areas, which includes lineaments, fault zones and fracture patterns. The identification of these features is fundamental in exploration geology, as it allows the definition of suitable sites for the exploitation of different resources (e.g. ore mineral, hydrocarbon, geothermal energy and groundwater). Remote sensing techniques, typically adopted in fault identification, have been applied to assess the geological and structural framework of the Laguna Blanca area (26°35'S-66°49'W). This area represents a sector of the south-central Andes localized in the Argentina region of Catamarca, along the south-eastern margin of the Puna plateau. The study area is characterized by a Precambrian low-grade metamorphic basement intruded by Ordovician granitoids. These rocks are unconformably covered by a volcano-sedimentary sequence of Miocene age, followed by volcanic and volcaniclastic rocks of Upper Miocene to Plio-Pleistocene age. All these units are cut by two systems of major faults, locally characterized by 15-20 m wide damage zones. The detection of main tectonic lineaments in the study area was firstly carried out by classical procedures: image sharpening of Landsat 7 ETM+ images, directional filters applied to ASTER images, medium resolution Digital Elevation Models analysis (SRTM and ASTER GDEM) and hill shades interpretation. In addition, a new approach in fault zone identification, based on multispectral satellite images classification, has been tested in the Laguna Blanca area and in other sectors of south-central Andes. In this perspective, several prominent fault zones affecting basement and granitoid rocks have been sampled. The collected fault gouge samples have been analyzed with a Field-Pro spectrophotometer mounted on a goniometer. We acquired bidirectional reflectance spectra, from 0.35μm to 2.5μm with 1nm spectral sampling, of the sampled fault rocks

  2. Ultrafast lattice dynamics in photoexcited nanostructures. Femtosecond X-ray diffraction with optimized evaluation schemes

    International Nuclear Information System (INIS)

    Schick, Daniel

    2013-01-01

    Within the course of this thesis, I have investigated the complex interplay between electron and lattice dynamics in nanostructures of perovskite oxides. Femtosecond hard X-ray pulses were utilized to probe the evolution of atomic rearrangement directly, which is driven by ultrafast optical excitation of electrons. The physics of complex materials with a large number of degrees of freedom can be interpreted once the exact fingerprint of ultrafast lattice dynamics in time-resolved X-ray diffraction experiments for a simple model system is well known. The motion of atoms in a crystal can be probed directly and in real-time by femtosecond pulses of hard X-ray radiation in a pump-probe scheme. In order to provide such ultrashort X-ray pulses, I have built up a laser-driven plasma X-ray source. The setup was extended by a stable goniometer, a two-dimensional X-ray detector and a cryogen-free cryostat. The data acquisition routines of the diffractometer for these ultrafast X-ray diffraction experiments were further improved in terms of signal-to-noise ratio and angular resolution. The implementation of a high-speed reciprocal-space mapping technique allowed for a two-dimensional structural analysis with femtosecond temporal resolution. I have studied the ultrafast lattice dynamics, namely the excitation and propagation of coherent phonons, in photoexcited thin films and superlattice structures of the metallic perovskite SrRuO 3 . Due to the quasi-instantaneous coupling of the lattice to the optically excited electrons in this material a spatially and temporally well-defined thermal stress profile is generated in SrRuO 3 . This enables understanding the effect of the resulting coherent lattice dynamics in time-resolved X-ray diffraction data in great detail, e.g. the appearance of a transient Bragg peak splitting in both thin films and superlattice structures of SrRuO 3 . In addition, a comprehensive simulation toolbox to calculate the ultrafast lattice dynamics and the

  3. Three-Dimensional Photography for Quantitative Assessment of Penile Volume-Loss Deformities in Peyronie's Disease.

    Science.gov (United States)

    Margolin, Ezra J; Mlynarczyk, Carrie M; Mulhall, John P; Stember, Doron S; Stahl, Peter J

    2017-06-01

    Non-curvature penile deformities are prevalent and bothersome manifestations of Peyronie's disease (PD), but the quantitative metrics that are currently used to describe these deformities are inadequate and non-standardized, presenting a barrier to clinical research and patient care. To introduce erect penile volume (EPV) and percentage of erect penile volume loss (percent EPVL) as novel metrics that provide detailed quantitative information about non-curvature penile deformities and to study the feasibility and reliability of three-dimensional (3D) photography for measurement of quantitative penile parameters. We constructed seven penis models simulating deformities found in PD. The 3D photographs of each model were captured in triplicate by four observers using a 3D camera. Computer software was used to generate automated measurements of EPV, percent EPVL, penile length, minimum circumference, maximum circumference, and angle of curvature. The automated measurements were statistically compared with measurements obtained using water-displacement experiments, a tape measure, and a goniometer. Accuracy of 3D photography for average measurements of all parameters compared with manual measurements; inter-test, intra-observer, and inter-observer reliabilities of EPV and percent EPVL measurements as assessed by the intraclass correlation coefficient. The 3D images were captured in a median of 52 seconds (interquartile range = 45-61). On average, 3D photography was accurate to within 0.3% for measurement of penile length. It overestimated maximum and minimum circumferences by averages of 4.2% and 1.6%, respectively; overestimated EPV by an average of 7.1%; and underestimated percent EPVL by an average of 1.9%. All inter-test, inter-observer, and intra-observer intraclass correlation coefficients for EPV and percent EPVL measurements were greater than 0.75, reflective of excellent methodologic reliability. By providing highly descriptive and reliable measurements of

  4. Effect of Various Treatment Modalities on Surface Characteristics and Shear Bond Strengths of Polyetheretherketone-Based Core Materials.

    Science.gov (United States)

    Çulhaoğlu, Ahmet Kürşat; Özkır, Serhat Emre; Şahin, Volkan; Yılmaz, Burak; Kılıçarslan, Mehmet Ali

    2017-11-13

    To investigate the effect of different surface treatments on the surface roughness (Ra), wettability, and shear bond strength of polyetheretherketone (PEEK) to composite resin. One hundred ninety eight PEEK specimens were divided into six groups (n = 33). Specimen surfaces were treated with the following surface treatment modalities: silicoating (CoJet), acetone treatment, acid etching (H 2 SO 4 ), airborne particle abrasion (Al 2 O 3 ), laser irradiation (Yb:PL laser), and the nontreated surface serving as the control. Surface roughness was measured with an profilometer (n = 11) and a goniometer was used to measure the surface wettability through contact angle (θ)(n = 11). PEEK surfaces were veneered with a composite resin (n = 11). The specimens were then thermocycled for 10,000 cycles at 5 to 55°C. Shear bond strengths between the PEEK and composite resin were measured with an universal test machine. One-way ANOVA was used to analyze the data. Tukey's post-hoc test was used to determine significant differences between groups (α = 0.05). Surface roughness and wettability of PEEK surfaces along with shear bond strength of PEEK to composite resin were influenced by the surface treatments. (p PEEK surfaces treated by laser irradiation (2.85 ± 0.2 µm) followed by airborne particle abrasion (2.26 ± 0.33 µm), whereas other surface treatment modalities provided similar Ra values, with the acid-etched PEEK surfaces having the lowest mean Ra values (0.35 ± 0.14 µm). Silicoating provided the most wettable PEEK surfaces (48.04 ± 6.28º), followed by either acetone treatment (70.19 ± 4.49º) or acid treatment (76.07 ± 6.61º). Decreased wettability was observed for airborne particle abraded (84.83 ± 4.56º) and laser-treated PEEK surfaces (103.06 ± 4.88º). The highest mean shear bond strength values were observed for acid-etched PEEK surfaces (15.82 ± 4.23 MPa) followed by laser irradiated (11.46 ± 1.97 MPa), airborne particle abraded (10.81 ± 3.06 MPa

  5. Validity and reliability of using photography for measuring knee range of motion: a methodological study

    Directory of Open Access Journals (Sweden)

    Adie Sam

    2011-04-01

    Full Text Available Abstract Background The clinimetric properties of knee goniometry are essential to appreciate in light of its extensive use in the orthopaedic and rehabilitative communities. Intra-observer reliability is thought to be satisfactory, but the validity and inter-rater reliability of knee goniometry often demonstrate unacceptable levels of variation. This study tests the validity and reliability of measuring knee range of motion using goniometry and photographic records. Methods Design: Methodology study assessing the validity and reliability of one method ('Marker Method' which uses a skin marker over the greater trochanter and another method ('Line of Femur Method' which requires estimation of the line of femur. Setting: Radiology and orthopaedic departments of two teaching hospitals. Participants: 31 volunteers (13 arthritic and 18 healthy subjects. Knee range of motion was measured radiographically and photographically using a goniometer. Three assessors were assessed for reliability and validity. Main outcomes: Agreement between methods and within raters was assessed using concordance correlation coefficient (CCCs. Agreement between raters was assessed using intra-class correlation coefficients (ICCs. 95% limits of agreement for the mean difference for all paired comparisons were computed. Results Validity (referenced to radiographs: Each method for all 3 raters yielded very high CCCs for flexion (0.975 to 0.988, and moderate to substantial CCCs for extension angles (0.478 to 0.678. The mean differences and 95% limits of agreement were narrower for flexion than they were for extension. Intra-rater reliability: For flexion and extension, very high CCCs were attained for all 3 raters for both methods with slightly greater CCCs seen for flexion (CCCs varied from 0.981 to 0.998. Inter-rater reliability: For both methods, very high ICCs (min to max: 0.891 to 0.995 were obtained for flexion and extension. Slightly higher coefficients were obtained

  6. Goniometria dos membros pélvicos de pacas (Cuniculus paca criadas em cativeiro Goniometry of the hind limbs of pacas (Cuniculus paca raised in captivity

    Directory of Open Access Journals (Sweden)

    Fábio André Pinheiro de Araújo

    2009-12-01

    Full Text Available O trabalho teve por objetivo avaliar por meio de estudos goniométricos os membros pélvicos de pacas criadas em cativeiro. Foram utilizadas oito pacas (Cuniculus paca, sendo três fêmeas e cinco machos, com peso entre 6,0 kg e 8,2 kg, nos quais foi aferido o movimento de extensão e flexão das articulações coxofemoral, joelho e tarsocrural utilizando-se um goniômetro de plástico. Foram realizadas duas aferições para cada membro pelo mesmo avaliador, com intervalo de uma semana entre cada aferição, com os animais sob anestesia dissociativa. Não houve diferença estatística nas aferições dos ângulos entres os momentos. As variações entre as medidas de flexão e extensão, efetuadas em cada momento pelo mesmo avaliador, foi entre 1º e 5º para cada membro. Os valores goniométricos médios foram: flexão de 43,96º±7,62 e extensão de 118,31º±9,79 para a articulação coxofemoral; flexão de 54,25º±10,24 e extensão 131,53º±7,89 para o joelho; flexão de 45,94º±7,16 e extensão de 145,03º±5,06 para a articulação tarsocrural. Sendo assim, observou-se que a amplitude de movimento das pacas é maior na articulação tarsocrural, seguida respectivamente do joelho e da articulação coxofemoral.The aim of this study was to evaluate by goniometry the hind limbs of pacas raised in captivity. Eight mature pacas (Cuniculus paca, three females and five males, weighing 6.0-8.2 kg, were used. The quantity of joint flexion and extension motion of the hip joint, stifle joint and tarsocrural joint was measured using a plastic standard goniometer. Under dissociative anesthesia, two measures were made for each member in each animal by the same observer at an interval of one week. There were no statistical differences of the quantity of joint motion between the moments. The flexion and extension angles varied from 1º to 5º in each moment for the same observer. The mean values of the angles of flexion and extension were, respectively

  7. Myofascial trigger points, neck mobility, and forward head posture in episodic tension-type headache.

    Science.gov (United States)

    Fernández-de-Las-Peñas, César; Cuadrado, Maria L; Pareja, Juan A

    2007-05-01

    To assess the differences in the presence of trigger points (TrPs) in head and neck muscles, forward head posture (FHP) and neck mobility between episodic tension-type headache (ETTH) subjects and healthy controls. In addition, we assess the relationship between these muscle TrPs, FHP, neck mobility, and several clinical variables concerning the intensity and the temporal profile of headache. TTH is a headache in which musculoskeletal disorders of the craniocervical region might play an important role in its pathogenesis. Design.-A blinded, controlled pilot study. Fifteen ETTH subjects and 15 matched controls without headache were studied. TrPs in both upper trapezius, both sternocleidomastoids, and both temporalis muscles were identified according to Simons and Gerwin diagnostic criteria (tenderness in a hypersensible spot within a palpable taut band, local twitch response elicited by snapping palpation, and elicited referred pain with palpation). Side-view pictures of each subject were taken in both sitting and standing positions, in order to assess FHP by measuring the craniovertebral angle. A cervical goniometer was employed to measure neck mobility. All measures were taken by a blinded assessor. A headache diary was kept for 4 weeks in order to assess headache intensity, frequency, and duration. The mean number of TrPs for each ETTH subject was 3.7 (SD: 1.3), of which 1.9 (SD: 0.9) were active, and 1.8 (SD: 0.9) were latent. Control subjects only had latent TrPs (mean: 1.5; SD: 1). TrP occurrence between the 2 groups was significantly different for active TrPs (P .05). Differences in the distribution of TrPs were significant for the right upper trapezius muscles (P= .04), the left sternocleidomastoid (P= .03), and both temporalis muscles (P < .001). Within the ETTH group, headache intensity, frequency, and duration outcomes did not differ depending on TrP activity, whether the TrP was active or latent. The craniovertebral angle was smaller, ie, there was a

  8. Cross-education for improving strength and mobility after distal radius fractures: a randomized controlled trial.

    Science.gov (United States)

    Magnus, Charlene R A; Arnold, Cathy M; Johnston, Geoffrey; Dal-Bello Haas, Vanina; Basran, Jenny; Krentz, Joel R; Farthing, Jonathan P

    2013-07-01

    To evaluate the effects of cross-education (contralateral effect of unilateral strength training) during recovery from unilateral distal radius fractures on muscle strength, range of motion (ROM), and function. Randomized controlled trial (26-wk follow-up). Hospital, orthopedic fracture clinic. Women older than 50 years with a unilateral distal radius fracture. Fifty-one participants were randomized and 39 participants were included in the final data analysis. Participants were randomized to standard rehabilitation (Control) or standard rehabilitation plus strength training (Train). Standard rehabilitation included forearm casting for 40.4±6.2 days and hand exercises for the fractured extremity. Nonfractured hand strength training for the training group began immediately postfracture and was conducted at home 3 times/week for 26 weeks. The primary outcome measure was peak force (handgrip dynamometer). Secondary outcomes were ROM (flexion/extension; supination/pronation) via goniometer and the Patient Rated Wrist Evaluation questionnaire score for the fractured arm. For the fractured hand, the training group (17.3±7.4kg) was significantly stronger than the control group (11.8±5.8kg) at 12 weeks postfracture (P<.017). There were no significant strength differences between the training and control groups at 9 (12.5±8.2kg; 11.3±6.9kg) or 26 weeks (23.0±7.6kg; 19.6±5.5kg) postfracture, respectively. Fractured hand ROM showed that the training group had significantly improved wrist flexion/extension (100.5°±19.2°) than the control group (80.2°±18.7°) at 12 weeks postfracture (P<.017). There were no significant differences between the training and control groups for flexion/extension ROM at 9 (78.0°±20.7°; 81.7°±25.7°) or 26 weeks (104.4°±15.5°; 106.0°±26.5°) or supination/pronation ROM at 9 (153.9°±23.9°; 151.8°±33.0°), 12 (170.9°±9.3°; 156.7°±20.8°) or 26 weeks (169.4°±11.9°; 162.8°±18.1°), respectively. There were no

  9. The impacts of pyrolysis temperature and feedstock type on biochar properties and the effects of biochar application on the properties of a sandy loam

    Science.gov (United States)

    Aston, Steve; Doerr, Stefan; Street-Perrott, Alayne

    2013-04-01

    The production of biochar and its application to soil has the potential to make a significant contribution to climate change mitigation whilst simultaneously improving soil fertility, crop yield and soil water-holding capacity. Biochar is produced from various biomass feedstock materials at varying pyrolysis temperatures, but relatively little is known about how these parameters affect the properties of the resultant biochars and their impact on the properties of the soils to which they are subsequently applied. Salix viminalis, M. giganteus and Picea sitchensis feedstocks were chipped then sieved to 2 - 5 mm, oven dried to constant weight, then pyrolyzed at 350, 500, 600 and 800° C in a nitrogen-purged tube furnace. Biochar yields were measured by weighing the mass of each sample before and after pyrolysis. Biochar hydrophobicity was assessed by using a goniometer to measure water-droplet contact-angles. Cation-exchange-capacity (CEC) was measured using the ammonium acetate method. Biochars were also produced in a rotary kiln from softwood pellets at 400, 500, 600 and 700° C then ground to 0.4 - 1 mm and applied to a sandy loam at a rate of 50 g kg-1. Bulk densities of these soil-biochar mixtures were measured on a tapped, dry, basis. The water-holding-capacity (WHC) of each mixture was measured gravimetrically following saturation and free-draining. The filter paper method was used to assess how pyrolysis temperature influences the effect of biochar application on matric suction. For all feedstocks, large decreases in biochar yield were observed between the pyrolysis temperatures of 350° C and 500° C. For Salix viminalis and M. giganteus feedstocks, subsequent reductions in the yield with increasing pyrolysis temperature were much lower. There were significant differences in hydrophobicity between biochars produced from different biomass and mean biochar hydrophobicity decreased with increasing pyrolysis temperature for all feedstocks. Results for CEC and WHC

  10. Interfacing ultracold atoms and cryogenic micromechanical oscillator

    Energy Technology Data Exchange (ETDEWEB)

    Bick, Andreas

    2015-02-06

    Why is it that our world, which consists of many microscopic quantum systems, can be described in terms of classical physics? This fundamental question about the transition between these two diametrically opposed theories is an unsolved problem of modern physics. In recent years, tremendous progress in the field of optomechanics paved the way for the observation of a large variety of quantum phenomena far beyond the microcosmos. Additional possibilities arise from the skillful combination of different quantum systems to create a so-called hybrid quantum system. In these systems, new possibilities to prepare and detect non-classical states in macroscopic systems arise. In this thesis the setup of a new hybrid quantum system is described that consists of two entirely different systems. The first building block is a {sup 87}Rb Bose-Einstein condensate (BEC) - an ideal realization of a many-body ground state. The second building block is an optomechanical system in a cryogenic environment, a membrane in an optical cavity (membrane in the middle - MiM). Both systems are coupled over a macroscopic distance via a light field. In this particular case, the MiM system is realized using a Si{sub 3}N{sub 4} membrane in a fiber-based Fabry-Perot cavity. In the course of this thesis, an asymmetric cavity with high reflectivity on resonance was identified as the ideal candidate. Such a system has not yet been reported in the literature, but allows for a strong coupling between the two constituents of the hybrid quantum system. Additionally, fibers are ideally suited to bring light into cryogenic environments due to their low thermal conductivity. In the cryostat, they will be mounted in novel five-axis goniometers. The key parameters for an asymmetric fiber-based cavity is the mode overlap between the cavity mode and the fiber mode. Due to an interference effect, a small change in the mode match already results in a massive amount of light loss of the reflected cavity mode in the

  11. Effects of adding whole body vibration to squat training on isometric force/time characteristics.

    Science.gov (United States)

    Lamont, Hugh S; Cramer, Joel T; Bemben, Debra A; Shehab, Randa L; Anderson, Mark A; Bemben, Michael G

    2010-01-01

    Resistance training interventions aimed at increasing lower-body power and rates of force development have produced varying results. Recent studies have suggested that whole-body low-frequency vibration (WBLFV) may elicit an acute postactivation potentiation response, leading to acute improvements in power and force development. Potentially, the use of WBLFV between sets of resistance training rather than during training itself may lead to increased recruitment and synchronization of high-threshold motor units, minimize fatigue potential, and facilitate the chronic adaptation to resistance exercise. The purpose of this study was to determine the effects of applying TriPlaner, WBLFV, prior to and then intermittently between sets of Smith machine squats on short-term adaptations in explosive isometric force expression. Thirty recreationally resistance trained men aged 18-30 were randomly assigned to 1 of 3 groups: resistance training only (SQT, n = 11), resistance plus whole-body vibration (SQTV, n = 13), or active control (CON, n = 6). An isometric squat test was performed prior to and following a 6-week periodized Smith machine squat program. Whole-body low-frequency vibration was applied 180 seconds prior to the first work set (50 Hz, 2-4 mm, 30 seconds) and intermittently (50 Hz, 4-6 mm, 3 x 10 seconds, 60 seconds between exposures) within a 240-second interset rest period. Subjects were instructed to assume a quarter squat posture while positioning their feet directly under their center of mass, which was modified using a handheld goniometer to a knee angle of 135 +/- 5 degrees . Instructions were given to subjects to apply force as fast and as hard as possible for 3.5 seconds. Isometric force (N) and rates of force development (N.s(-1)) were recorded from the onset of contraction (F(0)) to time points corresponding to 30, 50, 80, 100, 150, and 250 milliseconds, as well as the peak isometric rate of force development (PISORFD), and rate of force development to

  12. Wettability of poultry litter biochars at variable pyrolysis temperatures and their impact on soil wettability and water retention relationships

    Science.gov (United States)

    Yi, S. C.; Witt, B.; Guo, M.; Chiu, P.; Imhoff, P. T.

    2012-12-01

    To reduce the impact of poultry farming on greenhouse gas emissions, poultry farming waste - poultry litter - can be converted to biofuel and biochar through slow-pyrolysis, with the biochar added to agricultural soil for nutrient enrichment and carbon sequestration. While biochars from source materials other than poultry litter have been shown to sequester carbon and increase soil fertility, there is considerable variability in biochar behavior - even with biochars created from the same source material. This situation is exacerbated by our limited understanding of how biochars alter physical, chemical, and biological processes in agricultural soils. The focus of this work is to develop a mechanistic understanding of how poultry litter (PL) biochars affect the hydrology, microbial communities, N2O emissions, and nitrogen cycling in agricultural soils. The initial focus is on the impact of PL biochar on soil hydrology. PL from Perdue AgriRecycle, LLC (Seaford, Delaware) was used to produce biochars at pyrolysis temperatures from 300°C to 600°C. To explore the impact of these biochars on soil wettability, the PL biochars were mixed with a 30/40 Accusand in mass fractions from 0% to 100%. The water contact angle was then measured using a goniometer on these sand/biochar mixtures using the sessile drop method and a single layer of sample particles. The PL biochars produced at temperatures between 300°C to 400°C were hydrophobic, while those pyrolized at > 400°C were hydrophilic. Water contact angles for samples with 100% biochar varied systematically with pyrolysis temperature, decreasing from 101.12° to 20.57° as the pyrolysis temperature increased from 300 to 600°C. Even for small amounts of hydrophobic biochar added to the hydrophilic sand, the contact angle of the mixture was altered: for sand/biochar mixtures containing only 2% hydrophobic PL biochar by weight, the contact angle of the mixture increased from ~ 8° (0% biochar) to 20° (2% biochar). For

  13. ROM a primera vista = ROM at first sight

    Directory of Open Access Journals (Sweden)

    Hugo Ricardo, D

    2006-09-01

    Full Text Available RESUMEN Objetivo:Es por todos conocida la importancia en la medición delROM (Range of motion: Rango de movimiento de una articulación, como elemento diagnóstico y evolutivo, pero, falta de uniformidad existe respecto a como debería ser registrado el ROM, de manera tal que otros profesionales pudieran interpretar los mismos resultados. Es objetivo de este trabajo, presentar una nueva técnica, rápida y eficaz para medir el ROM activo de las articulaciones de muñeca y dedos, sin necesidad de recurrir a un goniómetro o sistema similar.Material y métodos: La técnica se basa en darle a cada rango articular, desde la posición extrema, un valor máximo de 1 y un mínimo de 0 . Por ejemplo, si la extensión de muñeca es total, entonces corresponde valor 1; si la extensión de muñeca, no existe, entonces corresponde un valor de 0. Si la extensión llega a un 25% , se considera valor¼. Si la extensión llega a un 50%, se considera valor ½ .Si la extensión llega a un 75%, se considera valor ¾. Además, si al valor del ROM obtenido, le adosamos luego de un guión el valor 0, indicaráausencia de dolor. Si adosamos el valor 1, indicará presencia de dolor.Discusión: Esta técnica tiene evidentemente ciertas ventajas respecto a los métodos convencionales: Es más rápida, más cómoda, más simple, más fácil de aprender y recordar, y otros profesionales pueden apropiadamente interpretar los mismos resultados ABSTRACTObjective: we all are aware of the importance of the measuring of ROM in an articulation, as an element for diagnosis and evolution. Notwithstanding, there is a lack of uniformity concerning its registration to facilitate theinterpretation of the same results by other professionals.So that, the aim of this work is presenting a new, quick and effective technique to measure the active ROM of wrist and fingers joints without resorting to a goniometer or similar device.Material and methods: this technique consists of giving each

  14. The Effect of Kinesiotaping Implementation After Anterior Cruciate Ligament Reconstruction

    Science.gov (United States)

    Ural, İbrahim Halil; Duymaz, Tomris; Özgönenel, Levent

    2017-01-01

    Objective: The main aim of this study was to measure effects of kinesiotaping on pain and range of motion in the conservative treatment of postoperative anterior cruciate ligament(ACL) rupture. Material-Methods: A total of 26 patients(24 women, 2 men) who had unilateral ACL rupture 64.46±9.00 years old(46-81years), 13 had physiotherapy only(mean age 64.46±9.35 years),13 had physiotherapy and kinesiotape(mean age 64.46±9.01 years).The patients in both groups received physiotherapy program (ultrasound with 1 MHz, 1W/cm2 during 5minutes; CPM; strength exercise for quadriceps muscle and cold pack during 15 minute). Kinesiotape was applied to the knee and quadriceps of the patient’s leg using a prescribed application to facilitate muscle performance for the experimental group versus a only physiotherapy group.The patients were treated 20 times for four weeks. Socio-demographic variables (gender, age, body mass index, Kellgren-Lawrence system for classification of knee osteoarthritis, use of analgesic drug, pain during rest and activity (VAS=Visual Analog Scale), range of motion of knee flexion and extansion (universal goniometer), circumference measurements of the knee and the quadriceps muscle (up to 10 cm of patella) were measured at baseline, mid the treatment program and after the treatment program. Statistical analysis was conducted using SPSS 22.0 for Windows.Frequency and percentage (average, standard deviation)were used as descriptive statistics of the study.The Wilcoxon test was used to compare the differences between before and after treatment measurements.The Kruskal Wallis test was used to compare groups.Significance was accepted as pKinesiotape Group Physiotherapy Group p VAS rest Pretreatment 2.07±2.49 2.38±2.72 0.705 Midtreatment 0.46±0.96 1.84±2.03 0.056 Posttreatment 0.07±0.27 2.07±2.36 0.008* p 0.017* 0.046* VAS activity Pretreatment 4.69±3.19 6.00±2.08 0.253 Midtreatment 0.84±0.80 4.30±1.70 0.000** Posttreatment 0.15±0.37 3.61±1.75 0

  15. Cam Deformities and Limited Hip Range of Motion Are Associated With Early Osteoarthritic Changes in Adolescent Athletes: A Prospective Matched Cohort Study.

    Science.gov (United States)

    Wyles, Cody C; Norambuena, Germán A; Howe, Benjamin M; Larson, Dirk R; Levy, Bruce A; Yuan, Brandon J; Trousdale, Robert T; Sierra, Rafael J

    2017-11-01

    The natural history of femoroacetabular impingement (FAI) remains incompletely understood. In particular, there is limited documentation of joint damage in adolescent patients with limited range of motion (LROM) of the hip, which is commonly associated with FAI. To evaluate changes in magnetic resonance imaging (MRI), radiographs, and clinical examinations over 5 years in a group of athletes from a wide variety of sports with asymptomatic LROM of the hip compared with matched controls. Cohort study (prognosis); Level of evidence, 2. The authors screened 226 male and female athletes aged 12 to 18 years presenting for preparticipation sports physical examinations. Using a goniometer, we identified 13 participants with at least one hip having internal rotation hip flexed to 90°. Overall, 21 of 26 hips (81%) had internal rotation 10°. At the time of enrollment, all participants were asymptomatic and underwent a complete hip examination and radiographic imaging with radiographs (anteroposterior [AP] and von Rosen views) and non-arthrogram MRI. Participants returned at 5-year follow-up and underwent repeat hip examinations, imaging (AP and lateral radiographs and non-arthrogram MRI), and hip function questionnaires. MRI scans were classified as "normal" versus "abnormal" based on the presence of any of 13 scored chondral, labral, or osseous abnormalities. Comparisons between the LROM group and control group were performed using generalized linear models (either linear, logistic, or log-binomial regression as appropriate for the outcome) with generalized estimating equations to account for the within-participant correlation due to patients having both hips included. Relative risk (RR) estimates are reported with 95% CIs. At the time of study enrollment, 16 of 26 hips (62%) in the LROM group had abnormal MRI findings within the acetabular labrum or cartilage compared with 8 of 26 hips (31%) in the control group (RR, 2.0; 95% CI, 0.95-4.2; P = .067). The mean alpha angle

  16. Manganese-55 NMR and relaxation in single crystals of manganese(12)-Ac and analogs

    Science.gov (United States)

    Harter, Andrew

    This dissertation presents the first single crystal 55Mn NMR characterization of three compounds related to Mn12-acetate [Mn12O12(O2CCH3)16(H 2O)4]·2CH3COOH·4H2O (henceforth Mn12-Ac) that have come to be known as Single-Molecule Magnets (SMMs). This study was undertaken because they exhibit novel phenomena such as quantum mechanical tunneling of their magnetization (QTM), the origin of which is still not fully understood, and also because they have the potential to form elements of magnetic memory storage at the molecular dimensions. The investigations herein involve studies related to both the bonding as well as spin-dynamics in these compounds to much higher precision than in earlier work. These experiments were made possible by the design of a high frequency goniometer probe and a 3He temperature facility. The first single crystal NMR of any Mn12-based molecule was conducted on [Mn12O12(O2CCH2Br) 16(H2O)4]·4CH2Cl2 (Mn12-BrAc). Its 55Mn NMR spectrum, field dependence, angular dependence, and spin-lattice relaxation time (T 1) measurements were conducted. Most importantly, data are presented that (a) confirm the alteration of the magnetic core of these molecules when the samples are crushed into powder (a practice used in earlier studies), (b) show the presence of transverse hyperfine fields at the nuclear site, and (c) do not yield any evidence of temperature independent relaxation below 1 K, suggesting that QTM is not the dominant relaxation mechanism at these temperatures, in contrast to earlier studies. Data from single crystals of Mn12-Ac, the most studied SMM, concur with previous x-ray findings in that isomers are present. Such detailed information was not obtainable with powder samples. T 1-1 measurements over 400 mK--1 K indicate the existence of an energy barrier, in this case ˜1.65 K, which does not fit the current understanding of the electronic energy diagram. This value supports an earlier, yet unexplained observation of such a level by inelastic

  17. Effect of physical therapy on joint range of motion and muscle collagen deposition in the golden retriever muscular dystrophy (GRMD model Efeito da fisioterapia na amplitude de movimento articular e deposição de colágeno muscular no modelo golden retriever muscular dystrophy (GRMD

    Directory of Open Access Journals (Sweden)

    TP Gaiad

    2009-06-01

    Full Text Available OBJECTIVE: To elucidate the effect of physical therapy on joint range of motion (ROM and muscle fibrosis in GRMD animals. METHODS: This was a nonrandomized blinded study with a control group, with six months of intervention evaluated beforehand and afterwards. Six dystrophic male Golden Retrievers of mean age 10.16±3.46 months and weight 17.75±6.01 kg were divided into a treated group (n=3 and an untreated group. These groups of dogs were named: G1=treated group before treatment; G2=treated group after treatment; G3=untreated group before treatment; and G4=untreated group after treatment. G1 underwent a physical therapy program that consisted of a 300-meter circuit with obstacles. Stifle, tarsal, elbow and carpal ROM were assessed using a goniometer before and after treatment. The area of collagen in the vastus lateralis muscle was measured using histomorphometry. The locations of collagen types I, III and IV were studied using immunohistochemistry. RESULTS: The tarsal ROM values in G2 presented an increasing trend. The area of muscle collagen differed between the groups after treatment and an increasing trend in these values was observed in G4. Collagen types I and III were the ones most frequently observed, forming broad bands in the perimysium of both G2 and G4. Type I collagen was observed in the endomysium more than type III collagen. Type IV collagen was observed only in the basal layer. CONCLUSION: Physical Therapy seemed to improve tarsal ROM in the treated group without increasing muscular fibrosis.OBJETIVO: Elucidar o efeito da fisioterapia na Amplitude de Movimento Articular (ADM e na fibrose muscular em animais GRMD. MÉTODOS: Estudo não randomizado, com grupo controle, cego, seis meses de intervenção, avaliação antes e depois da intervenção. Seis animais da raça Golden Retriever, distróficos, machos, média de idade 10,16±3,46 meses e peso de 17,75±6,01 kg foram separados em grupo tratado (n=3 e não tratado. Esses

  18. Calibration of NRSF2 Instrument at HFIR

    International Nuclear Information System (INIS)

    Tang, Fei; Hubbard, Camden R.

    2006-01-01

    The Neutron Residual Stress Mapping Facility (NRSF2) at HB-2B is a new generation-diffraction instrument, adding many new Second Generation features, such as larger beam tube, large sample XYZ goniometer, and KAPPA orienter for a broad range of materials behavior studies. One key feature is the NRSF2 monochromator, which is a double focusing, double crystal monochromator system consisting of two sets of stacked Si crystal wafers. One set of wafers has Si[400] plane normal to the surface while the other set of wafers has the Si[500] normal to the surface. The monochromator crystal diffracts at a fixed diffraction angle of 88 o selecting a neutron wavelength determined by the monochromator d hkl -spacing. This 'Missouri' monochromator system has two independent monochromators, which enable diffraction from the following set of six diffraction planes: Si(511), Si(422), Si(331)AF (Anti-Fankuchen geometry), Si(400), Si(311), and Si(220). These diffraction planes can provide 6 different neutron wavelengths: approximately 1.45, 1.54, 1.73, 1.89 (angstrom), 2.27, and 2.66 also incorporate seven position sensitive detectors located in a detector shield box. To use this advanced instrument for scientific and engineering measurements, careful calibration needs to be performed to accurately calibrate the seven position sensitive detectors, neutron wavelength, and 2θ 0 . Just as in the X-ray diffraction technique, neutron diffraction directly measures the diffraction angle (2θ) or diffraction peak position, then based on Bragg's law and a strain free lattice spacing, the strain can be calculated. Therefore anything that can affect the diffracting angle measurement can influence the accuracy of the strain measurements. The sources of difficulties in achieving accurate neutron diffraction peak positions can be classified into three categories. (1) Instrument - These difficulties come from alignment of the monochromator, alignment of the incident and detector slits, leveling of

  19. Design, development, and evaluation of an automatic guidance system for tractor tracking along the contour line on inclined surfaces

    Directory of Open Access Journals (Sweden)

    S Dehghani

    2016-04-01

    to the computer and received angular position in x and y coordinates. An assumed degree could be considered as basis degree and the measured frequency was adjustable. The tilt sensor located along the axial length of tractor and leads the angles which are created by longitudinal axle transverse axle of the tractor in related to horizontal level. It was used for contour lines detecting. The potentiometer located on the steering wheel of the tractor and pressure sensor which used with goniometer sensor used keeping uniformly of leveling points in tractor motion. The pressure sensor (SN-SCP1000- South Korea which is used in leveling system can detect the elevation changes. In this way, by defining a limitation of altitude for system, it would be able to stop steering turning motor which was coupled to tractor steering rod automatically. By resetting, the tractor could be able to live in a new level position. To avoid excessive left and right steering wheels deviation and interfering with other lines of travel, potentiometer was used. The deviation degree for steering rod from center to left or right was selected 120 degrees. Accordingly, the wheels would not be able to move more than 10 degrees to each direction. The Processing System: The electrical circuit graphically designed and simulated by software (Altium Designer, 2009 and installed on the tractor. The components of this circuit are as follows: Electrical board, two relays which control the electrical pathway in both directions, a battery with 12 volts of electric potential as electrical power supply, ATmeGA32 microcontroller which was made by Atmel company as main core for information processing, RS232 protocol was used for making correlation between serial port (COM and the microcontroller and two capacitors for reducing noises. The Actuator System: The output signals from the a processing system, were lead in the actuator system would order and indicative of left- turn or right- turn command, were introduced