WorldWideScience

Sample records for gneration joint test

  1. US/USSR cooperative program in open-cycle MHD electrical power gneration. Joint test report No. 2: tests in the U-25B facility; MHD generator test No. 3

    International Nuclear Information System (INIS)

    Tempelmeyer, K.E.; Sokolov, Y.N.

    1979-04-01

    The third joint test with a Soviet U-25B MHD generator and a US superconducting magnet system (SCMS) was conducted in the Soviet U-25B Facility. The primary objectives of the 3rd test were: (1) to operate the facility and MHD channel over a wider range of test parameters, and (2) to study the performance of all components and systems of the flow train at increased mass flow rates of combustion products (up to 4 kg/s), at high magnetic-field induction (up to 5 T), and high values of the electrical field in the MHD generator. The third test has demonstrated that all components and systems of the U-25B facility performed reliably. The electric power generated by the MHD generaor reached a maximum of 575 kW during this test. The MHD generator was operated under electrical loading conditions for 9 hours, and the combustor for a total of approximately 14 hours. Very high Hall fields (2.1 kV/m) were produced in the MHD channel, with a total Hall voltage of 4.24 kV. A detailed description is given of (1) performance of all components and systems of the U-25B facility, (2) analysis of the thermal, gasdynamic, and electrical characteristics of the MHD generator, (3) results of plasma diagnostic studies, (4) studies of vibrational characteristics of the flow train, (5) fluctuation of electrodynamic and gasdynamic parameters, (6) interaction of the MHD generator with the superconducting magnet, and (7) an operational problem, which terminated the test

  2. Determination of Parachute Joint Factors using Seam and Joint Testing

    Science.gov (United States)

    Mollmann, Catherine

    2015-01-01

    This paper details the methodology for determining the joint factor for all parachute components. This method has been successfully implemented on the Capsule Parachute Assembly System (CPAS) for the NASA Orion crew module for use in determining the margin of safety for each component under peak loads. Also discussed are concepts behind the joint factor and what drives the loss of material strength at joints. The joint factor is defined as a "loss in joint strength...relative to the basic material strength" that occurs when "textiles are connected to each other or to metals." During the CPAS engineering development phase, a conservative joint factor of 0.80 was assumed for each parachute component. In order to refine this factor and eliminate excess conservatism, a seam and joint testing program was implemented as part of the structural validation. This method split each of the parachute structural joints into discrete tensile tests designed to duplicate the loading of each joint. Breaking strength data collected from destructive pull testing was then used to calculate the joint factor in the form of an efficiency. Joint efficiency is the percentage of the base material strength that remains after degradation due to sewing or interaction with other components; it is used interchangeably with joint factor in this paper. Parachute materials vary in type-mainly cord, tape, webbing, and cloth -which require different test fixtures and joint sample construction methods. This paper defines guidelines for designing and testing samples based on materials and test goals. Using the test methodology and analysis approach detailed in this paper, the minimum joint factor for each parachute component can be formulated. The joint factors can then be used to calculate the design factor and margin of safety for that component, a critical part of the design verification process.

  3. Torsion testing of bed joints

    DEFF Research Database (Denmark)

    Hansen, Klavs Feilberg; Pedersen, Carsten Mørk

    2008-01-01

    This paper describes a simple test method for determining the torsion strength of a single bed joint between two bricks and presents results from testing using this test method. The setup for the torsion test is well defined, require minimal preparation of the test specimen and the test can...... be carried out directly in a normal testing machine. The torsion strength is believed to be the most important parameter in out-of-plane resistance of masonry walls subjected to bending about an axis perpendicular to the bed joints. The paper also contains a few test results from bending of small walls about...... an axis perpendicular to the bed joints, which indicate the close connection between these results and results from torsion tests. These characteristics make the torsion strength well suited to act as substitute parameter for the bending strength of masonry about an axis perpendicular to the bed joints....

  4. Space Suit Joint Torque Testing

    Science.gov (United States)

    Valish, Dana J.

    2011-01-01

    In 2009 and early 2010, a test was performed to quantify the torque required to manipulate joints in several existing operational and prototype space suits in an effort to develop joint torque requirements appropriate for a new Constellation Program space suit system. The same test method was levied on the Constellation space suit contractors to verify that their suit design meets the requirements. However, because the original test was set up and conducted by a single test operator there was some question as to whether this method was repeatable enough to be considered a standard verification method for Constellation or other future space suits. In order to validate the method itself, a representative subset of the previous test was repeated, using the same information that would be available to space suit contractors, but set up and conducted by someone not familiar with the previous test. The resultant data was compared using graphical and statistical analysis and a variance in torque values for some of the tested joints was apparent. Potential variables that could have affected the data were identified and re-testing was conducted in an attempt to eliminate these variables. The results of the retest will be used to determine if further testing and modification is necessary before the method can be validated.

  5. Kernel-based tests for joint independence

    DEFF Research Database (Denmark)

    Pfister, Niklas; Bühlmann, Peter; Schölkopf, Bernhard

    2018-01-01

    if the $d$ variables are jointly independent, as long as the kernel is characteristic. Based on an empirical estimate of dHSIC, we define three different non-parametric hypothesis tests: a permutation test, a bootstrap test and a test based on a Gamma approximation. We prove that the permutation test......We investigate the problem of testing whether $d$ random variables, which may or may not be continuous, are jointly (or mutually) independent. Our method builds on ideas of the two variable Hilbert-Schmidt independence criterion (HSIC) but allows for an arbitrary number of variables. We embed...... the $d$-dimensional joint distribution and the product of the marginals into a reproducing kernel Hilbert space and define the $d$-variable Hilbert-Schmidt independence criterion (dHSIC) as the squared distance between the embeddings. In the population case, the value of dHSIC is zero if and only...

  6. Pelamis WEC - full-scale joint system test

    Energy Technology Data Exchange (ETDEWEB)

    Yemm, R.

    2003-07-01

    This report describes the building and testing of a full-scale Pelamis Wave Energy Converter (WEC) two-axis joint system using a laboratory joint test rig. The main project objective to develop an intermediate demonstration model to confirm full scale control, hydraulic and data acquisition systems is discussed, and the key objectives of the programme are listed. Details are given of the semi-submerged articulated structure of cylindrical elements linked by hinged joints, and the integrated testing of all key components. A summary of the work programme and a description of the test rig are presented.

  7. Results and Analysis from Space Suit Joint Torque Testing

    Science.gov (United States)

    Matty, Jennifer

    2010-01-01

    This joint mobility KC lecture included information from two papers, "A Method for and Issues Associated with the Determination of Space Suit Joint Requirements" and "Results and Analysis from Space Suit Joint Torque Testing," as presented for the International Conference on Environmental Systems in 2009 and 2010, respectively. The first paper discusses historical joint torque testing methodologies and approaches that were tested in 2008 and 2009. The second paper discusses the testing that was completed in 2009 and 2010.

  8. Development and test of the ITER conductor joints

    Energy Technology Data Exchange (ETDEWEB)

    Martovetsky, N., LLNL

    1998-05-14

    Joints for the ITER superconducting Central Solenoid should perform in rapidly varying magnetic field with low losses and low DC resistance. This paper describes the design of the ITER joint and presents its assembly process. Two joints were built and tested at the PTF facility at MIT. Test results are presented, losses in transverse and parallel field and the DC performance are discussed. The developed joint demonstrates sufficient margin for baseline ITER operating scenarios.

  9. Large expansion joint movement test; Teste de movimentacao de juntas de expansao de grande porte

    Energy Technology Data Exchange (ETDEWEB)

    Medeiros, Jorivaldo; Veiga, Jordana Luiza Barbosa da Costa [PETROBRAS, Rio de Janeiro, RJ (Brazil); Veiga, Jose Carlos [Teadit, Rio de Janeiro, RJ (Brazil)

    2008-07-01

    This paper show the results obtained in a movement test realized on metallic bellows expansion joints used in the turbo expander duct system. A test device was developed. For dada acquisition a dynamometer was used and the tests were performed on gimbal expansion joints type. The joints were pressurized with water during the test. Data acquisition was realized at the design, operation and room pressure. The expansion joints were tested rotating them to the design angular movement of 3 deg and 6 deg degrees. The reactions for each degree of movement were recorded during loading and unloading. The tests confirmed that the expansion joints presented no-interference from construction, which configure in an adequate acceptance proceeding. It was noted the influence of internal pressure on reaction forces during expansion joints movements, these forces are not taken into consideration on theoretical calculations of EJMA design equations. The influence of friction on expansion joints hinges are significant and shall be considered on piping design and mitigated using friction reduction devices. (author)

  10. Neutron irradiation test of copper alloy/stainless steel joint materials

    International Nuclear Information System (INIS)

    Yamada, Hirokazu; Kawamura, Hiroshi

    2006-01-01

    As a study about the joint technology of copper alloy and stainless steel for utilization as cooling piping in International Thermonuclear Experimental Reactor (ITER), Al 2 O 3 -dispersed strengthened copper or CuCrZr was jointed to stainless steel by three kinds of joint methods (casting joint, brazing joint and friction welding method) for the evaluation of the neutron irradiation effect on joints. A neutron irradiation test was performed to three types of joints and each copper alloy. The average value of fast neutron fluence in this irradiation test was about 2 x 10 24 n/m 2 (E>1 MeV), and the irradiation temperature was about 130degC. As post-irradiation examinations, tensile tests, hardness tests and observation of fracture surface after the tensile tests were performed. All type joints changed to be brittle by the neutron irradiation effect like each copper alloy material, and no particular neutron irradiation effect due to the effect of joint process was observed. On the casting and friction welding, hardness of copper alloy near the joint boundary changed to be lower than that of each copper alloy by the effect of joint procedure. However, tensile strength of joints was almost the same as that of each copper alloy before/after neutron irradiation. On the other hand, tensile strength of joints by brazing changed to be much lower than CuAl-25 base material by the effect of joint process before/after neutron irradiation. Results in this study showed that the friction welding method and the casting would be able to apply to the joint method of piping in ITER. This report is based on the final report of the ITER Engineering Design Activities (EDA). (author)

  11. [Diagnostic test scale SI5: Assessment of sacroiliac joint dysfunction].

    Science.gov (United States)

    Acevedo González, Juan C; Quintero Oliveros, Silvia

    2015-01-01

    Sacroiliac joint dysfunction is a known cause of low back pain. We think that a diagnostic score scale (SI5) may be performed to assess diagnostic utility of clinical signs of sacroiliac joint dysfunction. The primary aim of the present study was to conduct the pilot study of our new diagnostic score scale, the SI5, for sacroiliac joint syndrome. We reviewed the literature on clinical characteristics, diagnostic tests and imaging most commonly used in diagnosing sacroiliac joint dysfunction. Our group evaluated the diagnostic utility of these aspects and we used those considered most representative to develop the SI5 diagnostic scale. The SI5 scale was applied to 22 patients with low back pain; afterwards, the standard test for diagnosing this pathology (selective blockage of the SI joint) was also performed on these patients. The sensitivity and specificity for each sign were also assessed and the diagnostic scale called SI5 was then proposed, based on these data. The most sensitive clinical tests for diagnosing SI joint dysfunction were 2 patient-reported clinical characteristics, the Laguerre Test, sacroiliac rocking test and Yeomans test (greater than 80% sensitivity). The tests with greatest diagnostic specificity (>80%) were the Lewitt test, Piedallu test and Gillet test. The proposed SI5 test score scale showed sensitivity of 73% and specificity of 71%. Sacroiliac joint syndrome has been shown to produce low back pain frequently; however, the diagnostic value of examination tests for sacroiliac joint pain has been questioned by other authors. The pilot study on the SI5 diagnostic score scale showed good sensitivity and specificity. However, the process of statistical validation of the SI5 needs to be continued. Copyright © 2014 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  12. Assessment of Aluminum FSW Joints Using Ultrasonic Testing

    Directory of Open Access Journals (Sweden)

    Adamus K.

    2017-12-01

    Full Text Available The paper concerns aluminum joints made using friction stir welding. Although in the aerospace industry there is a tendency to replace metal components with composites, aluminum continues to be a valuable material. Its share in the aircraft structures is the biggest among all structural metals. Lots of aluminum components are made of sheets and most of them require joining. Friction stir welding is a relatively new joining technology, particularly with regard to the sheets having a thickness of 1 mm or lower. The paper is dedicated to non-destructive testing of such joints using ultrasonic inspection. It was found that ultrasonic testing allows for distinguishing between joints without material discontinuities, joint with material discontinuities at the advancing side and joint with discontinuities extending through the whole width of the stir zone. During research only horizontally aligned defects were taken into account.

  13. Tensile Test of Welding Joint Parts for a Plate-type Fuel Assembly

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, K. H.; Kim, J. Y.; Kim, H. J.; Yim, J. S. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    The tensile tests were performed using an INSTRON 4505 (universal tensile) testing machine. These welding joints are composed of two parts for the soundness of the fuel assembly; one is the side plate with a fixing bar and the other is a side plate with an end fitting. These two joint parts are fabricated by TIG welding method. The tensile tests of the welding joints of a plate-type FA are executed by a tensile test. The fixture configurations for the specimen are very important to obtain the strict test results. The maximum strength has an approximately linear correlation with the unit bonding length of the welding joints. In spite of these results, the maximum strengths of the welding joints are satisfied according to the minimum requirement. These tensile tests of the joint parts for a plate-type fuel assembly (FA) have to be executed to evaluate the structural strength. For the tensile test, the joint parts of a FA used in the test are made of aluminum alloy (Al6061-T6)

  14. Tensile Test of Welding Joint Parts for a Plate-type Fuel Assembly

    International Nuclear Information System (INIS)

    Yoon, K. H.; Kim, J. Y.; Kim, H. J.; Yim, J. S.

    2013-01-01

    The tensile tests were performed using an INSTRON 4505 (universal tensile) testing machine. These welding joints are composed of two parts for the soundness of the fuel assembly; one is the side plate with a fixing bar and the other is a side plate with an end fitting. These two joint parts are fabricated by TIG welding method. The tensile tests of the welding joints of a plate-type FA are executed by a tensile test. The fixture configurations for the specimen are very important to obtain the strict test results. The maximum strength has an approximately linear correlation with the unit bonding length of the welding joints. In spite of these results, the maximum strengths of the welding joints are satisfied according to the minimum requirement. These tensile tests of the joint parts for a plate-type fuel assembly (FA) have to be executed to evaluate the structural strength. For the tensile test, the joint parts of a FA used in the test are made of aluminum alloy (Al6061-T6)

  15. Non-destructive testing of CFC/Cu joints

    International Nuclear Information System (INIS)

    Casalegno, V.; Ferraris, M.; Salvo, M.; Vesprini, R.; Merola, M.

    2006-01-01

    Reliable non-destructive tests (NDT) are fundamental for the manufacturing of ITER components, especially for high heat flux plasma facing components. NDT include various techniques, which allow inspection of a component without impairing serviceability; it's important to detect and characterize defects (type, size and position) as well as the set-up of acceptance standards in order to predict their influence on the component performance in service conditions. The present study shows a description of NDT used to assess the manufacturing quality of CFC (carbon fibre reinforced carbon matrix composites)/Cu/CuCrZr joints. In the ITER divertor, armor tiles made of CFC are joined to the cooling structure made of precipitation hardened copper alloy CuCrZr; a soft pure Cu interlayer is required between the heat sink and the armour in order to mitigate the stresses at the joint interface. NDT on CFC/Cu joint are difficult because of the different behavior of CFC and copper with regard to physical excitations (e.g. ultrasonic wave) used to test the component; furthermore the response to this input must be accurately studied to identify the detachment of CFC tiles from Cu alloy. The inspected CFC/Cu/CuCrZr joints were obtained through direct casting of pure Cu on modified CFC surface and subsequently through brazing of CFC/Cu joints to CuCrZr by a Cu-based alloy. Different non-destructive methods were used for inspecting these joints: lock-in thermography, ultrasonic inspections, microtomography and microradiography. The NDT tests were followed by metallographic investigation on the samples, since the reliability of a certain non destructive test can be only validated by morphological evidence of the detected defects. This study will undertake a direct comparison of NDT used on CFC/Cu joints in terms of real flaws presence. The purpose of this work is to detect defects at the joining interface as well as in the cast copper ( for instance voids). The experimental work was

  16. Phased array ultrasonic testing of dissimilar metal pipe weld joints

    International Nuclear Information System (INIS)

    Rajeev, J.; Sankaranarayanan, R.; Sharma, Govind K; Joseph, A.; Purnachandra Rao, B.

    2015-01-01

    Dissimilar metal weld (DMW) joints made of stainless steel and ferritic steel is used in nuclear industries as well as oil and gas industries. These joints are prone to frequent failures which makes the non-destructive testing of dissimilar metal weld joints utmost important for reliable and safe operation of nuclear power plants and oil and gas industries. Ultrasonic inspection of dissimilar metal weld joints is still challenging due to the inherent anisotropic and highly scattering nature. Phased array ultrasonic testing (PAUT) is an advanced technique and its capability has not been fully explored for the inspection of dissimilar metal welds

  17. Robust joint score tests in the application of DNA methylation data analysis.

    Science.gov (United States)

    Li, Xuan; Fu, Yuejiao; Wang, Xiaogang; Qiu, Weiliang

    2018-05-18

    Recently differential variability has been showed to be valuable in evaluating the association of DNA methylation to the risks of complex human diseases. The statistical tests based on both differential methylation level and differential variability can be more powerful than those based only on differential methylation level. Anh and Wang (2013) proposed a joint score test (AW) to simultaneously detect for differential methylation and differential variability. However, AW's method seems to be quite conservative and has not been fully compared with existing joint tests. We proposed three improved joint score tests, namely iAW.Lev, iAW.BF, and iAW.TM, and have made extensive comparisons with the joint likelihood ratio test (jointLRT), the Kolmogorov-Smirnov (KS) test, and the AW test. Systematic simulation studies showed that: 1) the three improved tests performed better (i.e., having larger power, while keeping nominal Type I error rates) than the other three tests for data with outliers and having different variances between cases and controls; 2) for data from normal distributions, the three improved tests had slightly lower power than jointLRT and AW. The analyses of two Illumina HumanMethylation27 data sets GSE37020 and GSE20080 and one Illumina Infinium MethylationEPIC data set GSE107080 demonstrated that three improved tests had higher true validation rates than those from jointLRT, KS, and AW. The three proposed joint score tests are robust against the violation of normality assumption and presence of outlying observations in comparison with other three existing tests. Among the three proposed tests, iAW.BF seems to be the most robust and effective one for all simulated scenarios and also in real data analyses.

  18. Testing of the Structure and Mechanical Properties of Technical Titanium Joints

    Directory of Open Access Journals (Sweden)

    Bogumił Wronka

    2013-01-01

    Full Text Available The aim of the research was the titanium pipeline welding technology. The transformations of this material due to the influence of thermal welding were analysed. The basic purpose was to evaluate the properties of titanium joint areas. Pipe joints of various thicknesses were welded by means of TIG argon arc welding while applying the optimum and reduced gas flow intensities. The structure and mechanical properties of these joints were tested. Different test results were obtained for joints welded in these two conditions. Recommendations concerning the welding technology and the heat treatment of joints after welding were presented.

  19. Naesliden Project: direct shear tests of filled and unfilled joints

    Energy Technology Data Exchange (ETDEWEB)

    Ludvig, B.

    1980-05-15

    Joints from the Naesliden mine have been tested in a small field shear box and in a large shear rig. The large shear rig is described in detail, and its ability to test joints with an area of 600 mc/sup 2/ at a maximum normal stress of up to 20 MPa is emphasized. The stiffness and shear strength of the discontinuities in the Naesliden mine is presented. The values estimated at direct shear tests are compared with results from in situ measurements and tests on drillcores. The results show that the in situ measurements give lower values for the shear resistance than the direct shear tests. Estimation of the normal stiffness for joints in drill cores gave much higher stiffness than the estimations in the shear rig.

  20. The CEA JOSEFA test facility for sub-size conductors and joints

    International Nuclear Information System (INIS)

    Decool, P.; Libeyre, P.; Van Houtte, D.; Ciazynski, D.; Zani, L.; Serries, J.P.; Cloez, H.; Bej, S.

    2003-01-01

    The JOSEFA (Joint Sub-size Experiment FAcility) experimental test facility, installed at CEA/Cadarache is devoted to perform tests at cryogenic temperature on sub-size superconducting conductor and joint samples under parallel or transverse magnetic field. This facility was built in 1993 to investigate the performances of joints of cable-in-conduit conductors at sub-size level and further upgraded in the framework of European tasks. The samples of hairpin type using sub-size ITER conductors are cooled by a circulation of supercritical helium in a temperature range from 5 to 15 K and tested at a maximum current up to 10 kA. Two different helium bath cooled magnets allow to apply DC or AC transverse magnetic field up to 3.5 T or longitudinal magnetic field up to 7.5 T. A sliding system with a 240 mm stroke on the sample cryostat allows to test separately in the same sample either the conductor or the joint performances. The paper reports on how, through the conductor and joint development tasks, the facility performances were successfully increased and tested. The ITER TFMC joints using Nb3Sn conductors were first developed on this facility. The last developments, performed on ITER PF NbTi conductors and joints proved this facility to be a versatile and useful tool for superconducting magnet developments and showed the interest of possible upgrading to finalize conductor design. (author)

  1. Comparative thermal cyclic testing and strength investigation of different Be/Cu joints

    Energy Technology Data Exchange (ETDEWEB)

    Gervash, A.; Giniyatulin, R.; Komarov, V.; Mazul, I.; Litunovsky, N. [Research Inst. of Electrophysical Apparatus, St. Petersburg (Russian Federation); Ganenko, A.; Vainerman, A. [CRISM `Prometey`, 193167, St. Petersburg (Russian Federation); Fedotov, V. [Moscow Physical Engineering Institute, 123060, Moscow (Russian Federation); Davydov, D. [Bochvar Institute, 123060, Moscow (Russian Federation); Zalavutdinov, R. [Institute of Physical Chemistry, Moscow (Russian Federation)

    1998-09-01

    One of the main problems for ITER divertor target technology is to provide a reliable joint between Be as armour material and copper alloy heat-sink structure. Such joints are to satisfy numerous requirements. In particular these joints should successfully withstand cyclic hear fluxes and should have good properties after neutron irradiation. To study such a complex problem, several investigation stages were planed in Russia. This paper presents the results of comparative thermal cyclic testing of different Be/Cu candidates. Summarising the thermal cyclic test results and analysing the metallography of those joints it was found that the life-time of all tested joints is limited by rather thick brittle intermetallic layers in the bonding zone caused by relatively long brazing time using heating and cooling down in traditional ohmic furnace. This paper thus presents attempts of using a unique brazing technique with fast e-beam heating. Metallographic investigation as well as X-ray spectrometric analysis of joints produced using the new technique were done. The recent results of testing of Be/Cu joints produced by fast e-beam brazing are discussed and some ideas for the nearest future investigations are presented. (orig.) 5 refs.

  2. Comparative thermal cyclic testing and strength investigation of different Be/Cu joints

    International Nuclear Information System (INIS)

    Gervash, A.; Giniyatulin, R.; Komarov, V.; Mazul, I.; Litunovsky, N.; Ganenko, A.; Vainerman, A.; Fedotov, V.; Davydov, D.; Zalavutdinov, R.

    1998-01-01

    One of the main problems for ITER divertor target technology is to provide a reliable joint between Be as armour material and copper alloy heat-sink structure. Such joints are to satisfy numerous requirements. In particular these joints should successfully withstand cyclic hear fluxes and should have good properties after neutron irradiation. To study such a complex problem, several investigation stages were planed in Russia. This paper presents the results of comparative thermal cyclic testing of different Be/Cu candidates. Summarising the thermal cyclic test results and analysing the metallography of those joints it was found that the life-time of all tested joints is limited by rather thick brittle intermetallic layers in the bonding zone caused by relatively long brazing time using heating and cooling down in traditional ohmic furnace. This paper thus presents attempts of using a unique brazing technique with fast e-beam heating. Metallographic investigation as well as X-ray spectrometric analysis of joints produced using the new technique were done. The recent results of testing of Be/Cu joints produced by fast e-beam brazing are discussed and some ideas for the nearest future investigations are presented. (orig.)

  3. Testing program for burning plasma experiment vacuum vessel bolted joint

    International Nuclear Information System (INIS)

    Hsueh, P.K.; Khan, M.Z.; Swanson, J.; Feng, T.; Dinkevich, S.; Warren, J.

    1992-01-01

    As presently designed, the Burning Plasma Experiment vacuum vessel will be segmentally fabricated and assembled by bolted joints in the field. Due to geometry constraints, most of the bolted joints have significant eccentricity which causes the joint behavior to be sensitive to joint clamping forces. Experience indicates that as a result of this eccentricity, the joint will tend to open at the side closest to the applied load with the extent of the opening being dependent on the initial preload. In this paper analytical models coupled with a confirmatory testing program are developed to investigate and predict the non-linear behavior of the vacuum vessel bolted joint

  4. Analysis of a beryllium-copper diffusion joint after HHF test

    International Nuclear Information System (INIS)

    Guiniatouline, R.N.; Mazul, I.V.; Gorodetsky, A.E.; Zalavutdinov, R.Kh.; Rybakov, S.Yu.; Savenko, V.I.

    1996-01-01

    The development of beryllium-copper joints which can withstand relevant ITER divertor conditions is one of the important tasks at the present time. One of the main problems associated with these joints is the intermetallic layers. The strength and life of these joints significantly depend on the width and contents of the intermetallic layers. The objective of this work is to study the diffusion joint of TGP-56 beryllium to OFHC copper after thermal response and thermocyclic tests with a beryllium-copper mock-up. The HHF test was performed on the e-beam facility (EBTS, SNLA). The following methods were used for analysis: roentgenographic analysis, X-ray spectrum analysis and fracture analysis. During the investigation the following studies were undertaken: the analysis of the diffusion boundary layer, which was obtained at the cross-section of one of the tiles, the analysis of the debonded surfaces of several beryllium tiles and corresponding copper parts and the analysis of the upper surface of one of the tiles after HHF tests. The joint roentgenographic and element analyses revealed the following phases in the diffusion zone: Cu 2 Be (∝170 μm), CuBe (∝30 μm), CuBe 2 (∝1 μm) and a solid solution of copper in beryllium. The phases Cu 2 Be, CuBe and the solid solution of copper in beryllium were detected by the quantitative microanalysis and the phases CuBe, CuBe 2 and CuBe, by the roentgenographic analysis. The fracture (origin) is located in the central part of the tiles. This crack was caused by residual stresses and thermal fatigue testing. This analysis provides important data on the joint quality and may be used for all types of joints used for ITER applications. (orig.)

  5. Material test data of SUS304 welded joints

    Energy Technology Data Exchange (ETDEWEB)

    Asayama, Tai [Japan Nuclear Cycle Development Inst., Oarai, Ibaraki (Japan). Oarai Engineering Center; Kawakami, Tomohiro [Nuclear Energy System Incorporation, Tokyo (Japan)

    1999-10-01

    This report summarizes the material test data of SUS304 welded joints. Numbers of the data are as follows: Tensile tests 71 (Post-irradiation: 39, Others: 32), Creep tests 77 (Post-irradiation: 20, Others: 57), Fatigue tests 50 (Post-irradiation: 0), Creep-fatigue tests 14 (Post-irradiation: 0). This report consists of the printouts from 'the structural material data processing system'. (author)

  6. Streamlined Approach for Environmental Restoration Work Plan for Corrective Action Unit 461: Joint Test Assembly Sites and Corrective Action Unit 495: Unconfirmed Joint Test Assembly Sites Tonopah Test Range, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    Jeff Smith

    1998-08-01

    This Streamlined Approach for Environmental Restoration plan addresses the action necessary for the clean closure of Corrective Action Unit 461 (Test Area Joint Test Assembly Sites) and Corrective Action Unit 495 (Unconfirmed Joint Test Assembly Sites). The Corrective Action Units are located at the Tonopah Test Range in south central Nevada. Closure for these sites will be completed by excavating and evaluating the condition of each artillery round (if found); detonating the rounds (if necessary); excavating the impacted soil and debris; collecting verification samples; backfilling the excavations; disposing of the impacted soil and debris at an approved low-level waste repository at the Nevada Test Site

  7. Push-off tests and strength evaluation of joints combining shrink fitting with bonding

    Science.gov (United States)

    Yoneno, Masahiro; Sawa, Toshiyuki; Shimotakahara, Ken; Motegi, Yoichi

    1997-03-01

    Shrink fitted joints have been used in mechanical structures. Recently, joints combining shrink fitting with anaerobic adhesives bonded between the shrink fitted surfaces have been appeared in order to increase the joint strength. In this paper, push-off test was carried out on strength of joints combining shrink fitting with bonding by material testing machine. In addition, the push-off strength of shrink fitting joints without an anaerobic adhesive was also measured. In the experiments, the effects of the shrinking allowance and the outer diameter of the rings on the joint strength are examined. The interface stress distribution in bonded shrink fitted joints subjected to a push-off load is analyzed using axisymmetrical theory of elasticity as a four-body contact problem. Using the interface stress distribution, a method for estimating joint strength is proposed. The experimental results are in a fairly good agreement with the numerical results. It is found that the strength of combination joints is greater than that of shrink fitted joints.

  8. Design and test of lightweight sandwich T-joint for naval ships

    DEFF Research Database (Denmark)

    Toftegaard, H.; Lystrup, Aa.

    2005-01-01

    Within the EUCLID project, 'Survivability, Durability and Performance of Naval Composite Structures', one task is to develop improved fibre composite joints for naval ship super structures. One type of joint in such a super structure is a T-joint between sandwich panels. An existing design consists...... of panels joined by filler and overlaminates of the same thickness as the skin laminates. Various improved T-joints have been designed and investigated. Some with focus on improved strength (survivability), and others with focus on reduced weight. This paper describes the design and test of a sandwich T...... triangles). A method for a finite element (FE) parameter study is developed and used for selection of a promising (strong) configuration of the T-joint. Tensile (pull-out) tests are performed to load the core triangles and filler in tension and the strength and failure mode are compared both with the FE...

  9. Working on a Standard Joint Unit: A pilot test.

    Science.gov (United States)

    Casajuana, Cristina; López-Pelayo, Hugo; Mercedes Balcells, María; Miquel, Laia; Teixidó, Lídia; Colom, Joan; Gual, Antoni

    2017-09-29

    Assessing cannabis consumption remains complex due to no reliable registration systems. We tested the likelihood of establishing a Standard Joint Unit (SJU) which considers the main cannabinoids with implication on health through a naturalistic approach.  Methodology. Pilot study with current cannabis users of four areas of Barcelona: universities, nightclubs, out-patient mental health service, and cannabis associations. We designed and administered a questionnaire on cannabis use-patterns and determined the willingness to donate a joint for analysis. Descriptive statistics were used to analyze the data. Forty volunteers answered the questionnaire (response rate 95%); most of them were men (72.5%) and young adults (median age 24.5 years; IQR 8.75 years) who consume daily or nearly daily (70%). Most participants consume marihuana (85%) and roll their joints with a median of 0.25 gr of marihuana. Two out of three (67.5%) stated they were willing to donate a joint. Obtaining an SJU with the planned methodology has proved to be feasible. Pre-testing resulted in an improvement of the questionnaire and retribution to incentivize donations. Establishing an SJU is essential to improve our knowledge on cannabis-related outcomes.

  10. Lap-joint testing of precoated steel materials

    Directory of Open Access Journals (Sweden)

    Chico, B.

    2003-12-01

    Full Text Available In industry, particularly in the building construction, lap-joint technology for precoated steel sheet materials has undergone rapid development. However, standars for lap-joint testing are lacking. This work analyses the behaviour of four precoated steel materials commonly used in the building industry: 55 % Al-Zn and hot dip galvanized, painted and unpainted. Two-year atmospheric exposure tests have been carried out in Madrid and Avilés (Spain, complemented by accelerated weathering tests in climatic cabinets. The latter have consisted of two salt fog/humidity/drying cycles: VDA cycle 621-415 and the "CENIM cycle", which has been designed to adequately simulate the behaviour of materials in this type of joints.

    En la industria en general y, particularmente, en la industria de la construcción, las tecnologías sobre uniones solapadas han experimentado un rápido desarrollo. Sin embargo, no son abundantes los ensayos para este tipo de uniones. Este trabajo analiza el comportamiento de cuatro materiales de acero pre-recubierto comúnmente usados en la industria de la construcción: 55 % Al-Zn y galvanizado por inmersión en caliente, con recubrimiento orgánico y sin él. Se han realizado ensayos de exposición natural durante dos años en las atmósferas de Madrid y Avilés (España, complementados con ensayos de envejecimiento acelerado en cámaras climáticas. En estos últimos se han ensayado dos ciclos de proyección niebla salina/humedad/secado: ciclo VDA 621-415 y un ciclo desarrollado en el CENIM diseñado.

  11. The analysis of beryllium-copper diffusion joint after HHF test

    International Nuclear Information System (INIS)

    Guiniatouline, R.N.; Mazul, I.V.; Rubkin, S.Y.

    1995-01-01

    The development of beryllium-copper joints which can withstand to relevant ITER divertor conditions is one of the important tasks at present time. One of the main problem for beryllium-copperjoints, is the inter-metallic layers, the strength and life time of joints significantly depends from the width and contents of the intermetallic layers. The objective of this work is to study the diffusion joint of TGP-56 beryllium to OFHC copper after thermal response and thermocyclic tests with beryllium-copper mockup. The BEY test were performed at e-beam facility (EBTS, SNLA). The following methods were used for analyses: the roentgenographic analysis; X-ray spectrum analysis; the fracture graphic analysis. During the investigation the followed studies were done: the analysis of diffusion boundary Be-Cu, which was obtained at the crossection of one of the tiles, the analysis of the debonded surfaces of a few beryllium tiles and corresponding copper parts; the analysis of upper surface of one of the tiles after HHF tests. The results of this work have showed that: the joint roentgenographic and elements analyses indicated the following phases in the diffusion zone: Cu 2 Be (∼170 μm), CuBe (∼30μm), CuBe 2 (∼1 μm) and solid solution of copper in beryllium. The phases Cu 2 Be, CuBe and solid solution of copper in beryllium were indicated using quantitative microanalysis and phases CuBe, CuBe 2 , Cu, Be - by roentgenographic analysis; the source of fracture (initial crack) is located in the central part of the tiles, the crack caused by the influence of residual stresses during cooling of a mock-up after fabrication and developed under the conditions of slow elastic-plastic growing during the process of thermal fatigue testing. The analysis gives the important data about joint's quality and also may be used for any type of joints and its comparison for ITER applications

  12. Accelerated Comparative Fatigue Strength Testing of Belt Adhesive Joints

    Science.gov (United States)

    Bajda, Miroslaw; Blazej, Ryszard; Jurdziak, Leszek

    2017-12-01

    Belt joints are the weakest link in the serial structure that creates an endless loop of spliced belt segments. This affects not only the lower strength of adhesive joints of textile belts in comparison to vulcanized splices, but also the replacement of traditional glues to more ecological but with other strength parameters. This is reflected in the lowered durability of adhesive joints, which in underground coal mines is nearly twice shorter than the operating time of belts. Vulcanized splices require high precision in performance, they need long time to achieve cross-linking of the friction mixture and, above all, they require specialized equipment (vulcanization press) which is not readily available and often takes much time to be delivered down, which means reduced mining output or even downtime. All this reduces the reliability and durability of adhesive joints. In addition, due to the consolidation on the Polish coal market, mines are joined into large economic units serviced by a smaller number of processing plants. The consequence is to extend the transport routes downstream and increase reliability requirements. The greater number of conveyors in the chain reduces reliability of supply and increases production losses. With high fixed costs of underground mines, the reduction in mining output is reflected in the increase in unit costs, and this at low coal prices on the market can mean substantial losses for mines. The paper describes the comparative study of fatigue strength of shortened samples of adhesive joints conducted to compare many different variants of joints (various adhesives and materials). Shortened samples were exposed to accelerated fatigue in the usually long-lasting dynamic studies, allowing more variants to be tested at the same time. High correlation between the results obtained for shortened (100 mm) and traditional full-length (3×250 mm) samples renders accelerated tests possible.

  13. US/Russian Joint Film Test

    Science.gov (United States)

    Slater, Richard

    1996-01-01

    A joint U.S./Russian film test was conducted during MIR Mission 18 to evaluate the effects of radiation on photographic film during long-duration space flights. Two duplicate sets of film were flown on this MIR mission: one set was processed and evaluated by the NASA/JSC Photographic Laboratory, and the other by the RKK Energia's Photographic Laboratory in Moscow. This preliminary report includes only the results of the JSC evaluation (excluding the SN-10 film which was not available for evaluation at the time this report was written). The final report will include an evaluation by JSC of the SN-10 film and an evaluation of the test data by the RKK Energia. ISC's evaluation of the test data showed the positive film flown was damaged very little when exposed to approximately 8 rads of radiation. Two of the three negative films were significantly damaged and the third film was damaged only moderately.

  14. STUDY, EVALUATION AND TEST OF SUBMODULE TO GIRDER BOLTED JOINT

    CERN Document Server

    Blocki, J; Miralles, Ll; Topilin, N D

    2000-01-01

    The object of the present work is to study the bolted joint submodule to girder. This joint is critical from the point of view of the mechanical integrity of the Tilecal Barrel and Extended Barrel modules and LAr Endcaps. Theoretical analysis, FEM calculations and tests have been carried out in order to find a solution that fulfils the safety factors design criteria.

  15. Fabrication and Testing of Durable Redundant and Fluted-Core Joints for Composite Sandwich Structures

    Science.gov (United States)

    Lin, Shih-Yung; Splinter, Scott C.; Tarkenton, Chris; Paddock, David A.; Smeltzer, Stanley S.; Ghose, Sayata; Guzman, Juan C.; Stukus, Donald J.; McCarville, Douglas A.

    2013-01-01

    The development of durable bonded joint technology for assembling composite structures is an essential component of future space technologies. While NASA is working toward providing an entirely new capability for human space exploration beyond low Earth orbit, the objective of this project is to design, fabricate, analyze, and test a NASA patented durable redundant joint (DRJ) and a NASA/Boeing co-designed fluted-core joint (FCJ). The potential applications include a wide range of sandwich structures for NASA's future launch vehicles. Three types of joints were studied -- splice joint (SJ, as baseline), DRJ, and FCJ. Tests included tension, after-impact tension, and compression. Teflon strips were used at the joint area to increase failure strength by shifting stress concentration to a less sensitive area. Test results were compared to those of pristine coupons fabricated utilizing the same methods. Tensile test results indicated that the DRJ design was stiffer, stronger, and more impact resistant than other designs. The drawbacks of the DRJ design were extra mass and complex fabrication processes. The FCJ was lighter than the DRJ but less impact resistant. With barely visible but detectable impact damages, all three joints showed no sign of tensile strength reduction. No compression test was conducted on any impact-damaged sample due to limited scope and resource. Failure modes and damage propagation were also studied to support progressive damage modeling of the SJ and the DRJ.

  16. Critical Joints in Large Composite Primary Aircraft Structures. Volume 3: Ancillary Test Results

    Science.gov (United States)

    Bunin, Bruce L.; Sagui, R. L.

    1985-01-01

    A program was conducted to develop the technology for critical structural joints for composite wing structure that meets all the design requirements of a 1990 commercial transport aircraft. The results of a comprehensive ancillary test program are summarized, consisting of single-bolt composite joint specimens tested in a variety of configurations. These tests were conducted to characterize the strength and load deflection properties that are required for multirow joint analysis. The composite material was Toray 300 fiber and Ciba-Geigy 914 resin, in the form of 0.005 and 0.01 inch thick unidirectional tape. Tests were conducted in single and double shear for loaded and unloaded hole configurations under both tensile and compressive loading. Two different layup patterns were examined. All tests were conducted at room temperature. In addition, the results of NASA Standard Toughness Test (NASA RP 1092) are reported, which were conducted for several material systems.

  17. Mechanical testing and development of the helical field coil joint for the Advanced Toroidal Facility

    International Nuclear Information System (INIS)

    Nelson, B.E.; Bryan, W.E.; Goranson, P.L.; Warwick, J.E.

    1985-01-01

    The helical field (HF) coil set for the Advanced Toroidal Facility (ATF) is an M = 12, l = 2, constant-ratio torsatron winding consisting of 2 coils, each with 14 turns of heavy copper conductor. The coils are divided into 24 identical segments to facilitate fabrication and minimize the assembly schedule. The segments are connected across through-bolted lap joints that must carry up to 124,000 A per turn for 5 s or 62,500 A steady-state. In addition, the joints must carry the high magnetic and thermal loads induced in the conductor and still fit within the basic 140- by 30-mm copper envelope. Extensive testing and development were undertaken to verify and refine the basic joint design. Tests included assembly force and clamping force for various types of misalignment; joint resistance as a function of clamping force; clamp bolt relaxation due to thermal cycling; fatigue testing of full-size, multiturn joint prototypes; and low-cycle fatigue and tensile tests of annealed CDA102 copper. The required performance parameters and actual test results, as well as the final joint configuration, are presented. 2 refs., 9 figs., 4 tabs

  18. Thermal cycling tests of actively cooled beryllium copper joints

    Energy Technology Data Exchange (ETDEWEB)

    Roedig, M.; Duwe, R.; Linke, J.; Schuster, A.; Wiechers, B. [Forschungszentrum Juelich GmbH (Germany)

    1998-01-01

    Screening tests (steady state heating) and thermal fatigue tests with several kinds of beryllium-copper joints have been performed in an electron beam facility. Joining techniques under investigation were brazing with silver containing and silver-free braze materials, hot isostatic pressing (HIP) and diffusion bonding (hot pressing). Best thermal fatigue performance was found for the brazed samples. (author)

  19. Critical joints in large composite primary aircraft structures. Volume 2: Technology demonstration test report

    Science.gov (United States)

    Bunin, Bruce L.

    1985-01-01

    A program was conducted to develop the technology for critical structural joints in composite wing structure that meets all the design requirements of a 1990 commercial transport aircraft. The results of four large composite multirow bolted joint tests are presented. The tests were conducted to demonstrate the technology for critical joints in highly loaded composite structure and to verify the analytical methods that were developed throughout the program. The test consisted of a wing skin-stringer transition specimen representing a stringer runout and skin splice on the wing lower surface at the side of the fuselage attachment. All tests were static tension tests. The composite material was Toray T-300 fiber with Ciba-Geigy 914 resin in 10 mil tape form. The splice members were metallic, using combinations of aluminum and titanium. Discussions are given of the test article, instrumentation, test setup, test procedures, and test results for each of the four specimens. Some of the analytical predictions are also included.

  20. A Practical Test Method for Mode I Fracture Toughness of Adhesive Joints with Dissimilar Substrates

    Energy Technology Data Exchange (ETDEWEB)

    Boeman, R.G.; Erdman, D.L.; Klett, L.B.; Lomax, R.D.

    1999-09-27

    A practical test method for determining the mode I fracture toughness of adhesive joints with dissimilar substrates will be discussed. The test method is based on the familiar Double Cantilever Beam (DCB) specimen geometry, but overcomes limitations in existing techniques that preclude their use when testing joints with dissimilar substrates. The test method is applicable to adhesive joints where the two bonded substrates have different flexural rigidities due to geometric and/or material considerations. Two specific features discussed are the use of backing beams to prevent substrate damage and a compliance matching scheme to achieve symmetric loading conditions. The procedure is demonstrated on a modified DCB specimen comprised of SRIM composite and thin-section, e-coat steel substrates bonded with an epoxy adhesive. Results indicate that the test method provides a practical means of characterizing the mode I fracture toughness of joints with dissimilar substrates.

  1. Quantitative investigation of ligament strains during physical tests for sacroiliac joint pain using finite element analysis.

    Science.gov (United States)

    Kim, Yoon Hyuk; Yao, Zhidong; Kim, Kyungsoo; Park, Won Man

    2014-06-01

    It may be assumed that the stability is affected when some ligaments are injured or loosened, and this joint instability causes sacroiliac joint pain. Several physical examinations have been used to diagnose sacroiliac pain and to isolate the source of the pain. However, more quantitative and objective information may be necessary to identify unstable or injured ligaments during these tests due to the lack of understanding of the quantitative relationship between the physical tests and the biomechanical parameters that may be related to pains in the sacroiliac joint and the surrounding ligaments. In this study, a three-dimensional finite element model of the sacroiliac joint was developed and the biomechanical conditions for six typical physical tests such as the compression test, distraction test, sacral apex pressure test, thigh thrust test, Patrick's test, and Gaenslen's test were modelled. The sacroiliac joint contact pressure and ligament strain were investigated for each test. The values of contact pressure and the combination of most highly strained ligaments differed markedly among the tests. Therefore, these findings in combination with the physical tests would be helpful to identify the pain source and to understand the pain mechanism. Moreover, the technology provided in this study might be a useful tool to evaluate the physical tests, to improve the present test protocols, or to develop a new physical test protocol. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Test facility for joints of subsize cable-in-conduit conductors for NET/ITER winding studies

    International Nuclear Information System (INIS)

    Jager, B.; Chaussonnet, P.; Ciazynski, D.; Serries, J.P.; Simon, R.

    1996-01-01

    The joints between superconducting cables of the ITER coils present a major problem to be solved. A low resistance is required for the cooling, whereas small losses in variable magnetic field are needed for the stability. Different types of joints have already been suggested. Some preliminary measurements have already been made on prototypes of joints cooled in a helium bath at 4.2 K and for low currents. The test facility presented herein allows testing joint prototypes at the 1/8th scale (current up to 10 kA). These joints are cooled under the same conditions as those of ITER, by circulation of supercritical helium. A dipole allows submitting the joint to magnetic fields up to 4 teslas and to field variation rates up to dB/dt = 42 T/s

  3. McMurray's Test and Joint Line Tenderness for Medial Meniscus ...

    African Journals Online (AJOL)

    The wide variations reported have an impact on clinical decision concerning whether to go for other diagnostic tests before going for diagnostic arthroscopy, which is considered as the gold standard.The purpose of this study was to determine the diagnostic value of Joint line tenderness and McMurray's test, as clinical signs ...

  4. Methodic recommendations on ultrasonic testing of pipeline austenitic butt joints

    International Nuclear Information System (INIS)

    Grebennik, V.S.; Lantukh, V.M.; Tajts, M.Z.; Ermolov, I.N.; Volkov, A.S.; Vyatskov, I.A.; Kesler, N.A.; Shchedrin, I.F.

    1989-01-01

    Recommendations for the application of ultrasonic testing of austenitic welded joints of the Du 500 pipelines with the walls 32-34 mm thick made of steel Kh18N10T are developed. The optimal values of the main parameters of ultrasonic testing are determined experimentally. Principles of calculation of the optimal parameters are considered. 1 ref.; 4 figs

  5. Reliability of Tubular Joints

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Thoft-Christensen, Palle

    In this paper the preliminary results obtained by tests on tubular joints are presented. The joints are T-joints and the loading is static. It is the intention in continuation of these tests to perform tests on other types of joints (e.g. Y-joints) and also with dynamic loading. The purpose...... of the test is partly to obtain empirical data for the ultimate load-carrying capacity of tubular T-joints and partly to obtain some experience in performing tests with tubular joints. It is well known that tubular joints are usually designed in offshore engineering on the basis of empirical formulas obtained...... by experimental test results. Therefore, there is a need for performing experimental tests in this area....

  6. Evaluation of pavement joint sealants :a new testing technique

    OpenAIRE

    Abo-Qudais, Saad A.

    1992-01-01

    A new method to evaluate the performance of sealants, used in rigid pavement joints, was developed. A special fixture was designed to transfer cyclic in-line deflection, applied by a testing machine, to cyclic normal and shear deflections on a sealant sandwiched between two-2 x 2 x 2 in. portland cement mortar cubes. The normal and shear deflections were applied simultaneously at a specific ratio controlled by the developed fixture. The new testing method simulates field ...

  7. Experimental tests on slip factor in friction joints: comparison between European and American Standards

    Directory of Open Access Journals (Sweden)

    Emanuele Maiorana

    2018-01-01

    Full Text Available Friction joints are used in steel structures submitted to cyclic loading such as, for example, in steel and composite bridges, in overhead cranes, and in equipment subjected to fatigue. Slip-critical steel joints with preloaded bolts are characterized by high rigidity and good performance against fatigue and vibrational phenomena. The most important parameter for the calculation of the bolt number in a friction connection is the slip factor, depending on the treatment of the plane surfaces inside the joint package. The paper focuses on the slip factor values reported in European and North American Specifications, and in literature references. The differences in experimental methods of slip test and evaluation of them for the mentioned standards are discussed. The results from laboratory tests regarding the assessment of the slip factor related to only sandblasted and sandblasted and coated surfaces are reported. Experimental data are compared with other results from the literature review to find the most influent parameters that control the slip factor in friction joint and differences between the slip tests procedures

  8. Minimum joint space width (mJSW) of patellofemoral joint on standing ''skyline'' radiographs: test-retest reproducibility and comparison with quantitative magnetic resonance imaging (qMRI)

    International Nuclear Information System (INIS)

    Simoni, Paolo; Jamali, Sanaa; Alvarez Miezentseva, Victoria; Albert, Adelin; Totterman, Saara; Schreyer, Edward; Tamez-Pena, Jose G.; Zobel, Bruno Beomonte; Gillet, Philippe

    2013-01-01

    To assess the intraobserver, interobserver, and test-retest reproducibility of minimum joint space width (mJSW) measurement of medial and lateral patellofemoral joints on standing ''skyline'' radiographs and to compare the mJSW of the patellofemoral joint to the mean cartilage thickness calculated by quantitative magnetic resonance imaging (qMRI). A couple of standing ''skyline'' radiographs of the patellofemoral joints and MRI of 55 knees of 28 volunteers (18 females, ten males, mean age, 48.5 ± 16.2 years) were obtained on the same day. The mJSW of the patellofemoral joint was manually measured and Kellgren and Lawrence grade (KLG) was independently assessed by two observers. The mJSW was compared to the mean cartilage thickness of patellofemoral joint calculated by qMRI. mJSW of the medial and lateral patellofemoral joint showed an excellent intraobserver agreement (interclass correlation (ICC) = 0.94 and 0.96), interobserver agreement (ICC = 0.90 and 0.95) and test-retest agreement (ICC = 0.92 and 0.96). The mJSW measured on radiographs was correlated to mean cartilage thickness calculated by qMRI (r = 0.71, p < 0.0001 for the medial PFJ and r = 0.81, p < 0.0001 for the lateral PFJ). However, there was a lack of concordance between radiographs and qMRI for extreme values of joint width and KLG. Radiographs yielded higher joint space measures than qMRI in knees with a normal joint space, while qMRI yielded higher joint space measures than radiographs in knees with joint space narrowing and higher KLG. Standing ''skyline'' radiographs are a reproducible tool for measuring the mJSW of the patellofemoral joint. The mJSW of the patellofemoral joint on radiographs are correlated with, but not concordant with, qMRI measurements. (orig.)

  9. Lack of consensus on tests and criteria for generalized joint hypermobility, Ehlers–Danlos syndrome

    DEFF Research Database (Denmark)

    Remvig, Lars; Flycht, Lise; Christensen, Karl Bang

    2014-01-01

    The objectives of this study were to register clinicians performance and opinion of importance of clinical tests for generalized joint hypermobility (GJH), Ehlers-Danlos syndrome, hypermobility type (EDS-HT) and joint hypermobility syndrome (JHS), and to reach a consensus among clinicians...

  10. A Test Method for Monitoring Modulus Changes during Durability Tests on Building Joint Sealants

    Science.gov (United States)

    Christopher C. White; Donald L. Hunston; Kar Tean Tan; Gregory T. Schueneman

    2012-01-01

    The durability of building joint sealants is generally assessed using a descriptive methodology involving visual inspection of exposed specimens for defects. It is widely known that this methodology has inherent limitations, including that the results are qualitative. A new test method is proposed that provides more fundamental and quantitative information about...

  11. Test and Analysis Correlation for a Y-Joint Specimen for a Composite Cryotank

    Science.gov (United States)

    Mason, Brian H.; Sleight, David W.; Grenoble, Ray

    2015-01-01

    The Composite Cryotank Technology Demonstration (CCTD) project under NASA's Game Changing Development Program (GCDP) developed space technologies using advanced composite materials. Under CCTD, NASA funded the Boeing Company to design and test a number of element-level joint specimens as a precursor to a 2.4-m diameter composite cryotank. Preliminary analyses indicated that the y-joint in the cryotank had low margins of safety; hence the y-joint was considered to be a critical design region. The y-joint design includes a softening strip wedge to reduce localized shear stresses at the skirt/dome interface. In this paper, NASA-developed analytical models will be correlated with the experimental results of a series of positive-peel y-joint specimens from Boeing tests. Initial analytical models over-predicted the experimental strain gage readings in the far-field region by approximately 10%. The over-prediction was attributed to uncertainty in the elastic properties of the laminate and a mismatch between the thermal expansion of the strain gages and the laminate. The elastic properties of the analytical model were adjusted to account for the strain gage differences. The experimental strain gages also indicated a large non-linear effect in the softening strip region that was not predicted by the analytical model. This non-linear effect was attributed to delamination initiating in the softening strip region at below 20% of the failure load for the specimen. Because the specimen was contained in a thermally insulated box during cryogenic testing to failure, delamination initiation and progression was not visualized during the test. Several possible failure initiation locations were investigated, and a most likely failure scenario was determined that correlated well with the experimental data. The most likely failure scenario corresponded to damage initiating in the softening strip and delamination extending to the grips at final failure.

  12. Reliability of a Functional Test Battery Evaluating Functionality, Proprioception and Strength of the Ankle Joint

    OpenAIRE

    YILDIZ, Yavuz; ŞEKİR, Ufuk; HAZNECİ, Bülent

    2009-01-01

    Aim: In contrast to the one-sided evaluation methods used in the past, combining multiple tests allows one to obtain a global assessment of the ankle joint. Materials and Methods: Twenty healthy male volunteers participated in this study. One component of the test battery included five different functional ability tests, which included: single limb hopping course, one-legged and triple-legged hop for distance, and six-meter (6-m) and cross 6-m hop for time. Ankle joint position sense and on...

  13. Mechanical properties of a 316L/T91 weld joint tested in lead-bismuth liquid

    International Nuclear Information System (INIS)

    Serre, Ingrid; Vogt, Jean-Bernard

    2009-01-01

    The mechanical strength of T91/316L weld joint assembled by electron beam process is investigated in air and in a liquid lead bismuth bath at 300 and 380 o C using the small punch test. It is shown that the mechanical response in air of the weld joint is similar to that of the T91 base material. The plastic deformation is mainly concentrated in the T91 part of the weld joint which promotes cracking in this material. Testing in liquid lead bismuth bath results in a reduction in ductility and the formation of brittle cracks. The T91/weld interface is found to be rather resistant as it cracks late in the test and after a large crack propagated in the T91 steel.

  14. Creep damage evaluation of low alloy steel weld joint by small punch creep testing

    International Nuclear Information System (INIS)

    Nishioka, Tomoya; Sawaragi, Yoshiatsu; Uemura, Hiromi

    2013-01-01

    The effect of sampling location on SPC (Small Punch Creep) tests were investigated for weld joints to establish evaluation method of Type IV creep behavior. The SPC specimen shape was 10mm diameter and 0.5mm thick round disc prepared from weld joints of 2.25Cr-1Mo low alloy steel. It was found that the center of SPC specimen should be 2mm apart from the weld interface as the recommended sampling location. Creep damage was imposed for large weld joint specimens by axial creep loading at 620degC, 52MPa with the interrupted time fraction of 0.34, 0.45, 0.64 and 0.82.SPC samples were prepared from those damaged specimens following the recommended way described in this paper. Among the various SPC tests conducted, good relationships were found for the test condition of 625degC, 200N. Namely, good relationships were obtained both between minimum deflection rate and creep life fraction, and between rupture time and creep life fraction. Consequently, creep life assessment of Type IV fracture by SPC tests could be well conducted using the sampling location and the test condition recommended in this paper. (author)

  15. Joint excitation synchronization characteristics of fatigue test for offshore wind turbine blade

    Science.gov (United States)

    Zhang, Lei-an; Yu, Xiang-yong; Wei, Xiu-ting; Liu, Wei-sheng

    2018-02-01

    In the case of the stiffness of offshore wind turbine blade is relatively large, the joint excitation device solves the problem of low accuracy of bending moment distribution, insufficient driving ability and long fatigue test period in single-point loading. In order to study the synchronous characteristics of joint excitation system, avoid blade vibration disturbance. First, on the base of a Lagrange equation, a mathematical model of combined excitation is formulated, and a numerical analysis of vibration synchronization is performed. Then, the model is constructed via MATLAB/Simulink, and the effect of the phase difference on the vibration synchronization characteristics is obtained visually. Finally, a set of joint excitation platform for the fatigue test of offshore wind turbine blades are built. The parameter measurement scheme is given and the correctness of the joint excitation synchronization in the simulation model is verified. The results show that when the rotational speed difference is 2 r/min, 30 r/min, the phase difference is 0, π/20, π/8 and π/4, as the rotational speed difference and the phase difference increase, the time required for the blade to reach a steady state is longer. When the phase difference is too large, the electromechanical coupling can no longer make the joint excitation device appear self-synchronizing phenomenon, so that the value of the phase difference develops toward a fixed value (not equal to 0), and the blade vibration disorder is serious, at this time, the effect of electromechanical coupling must be eliminated. The research results provide theoretical basis for the subsequent decoupling control algorithm and synchronization control strategy, and have good application value.

  16. Joint excitation synchronization characteristics of fatigue test for offshore wind turbine blade

    Directory of Open Access Journals (Sweden)

    Lei-an Zhang

    2018-02-01

    Full Text Available In the case of the stiffness of offshore wind turbine blade is relatively large, the joint excitation device solves the problem of low accuracy of bending moment distribution, insufficient driving ability and long fatigue test period in single-point loading. In order to study the synchronous characteristics of joint excitation system, avoid blade vibration disturbance. First, on the base of a Lagrange equation, a mathematical model of combined excitation is formulated, and a numerical analysis of vibration synchronization is performed. Then, the model is constructed via MATLAB/Simulink, and the effect of the phase difference on the vibration synchronization characteristics is obtained visually. Finally, a set of joint excitation platform for the fatigue test of offshore wind turbine blades are built. The parameter measurement scheme is given and the correctness of the joint excitation synchronization in the simulation model is verified. The results show that when the rotational speed difference is 2 r/min, 30 r/min, the phase difference is 0, π/20, π/8 and π/4, as the rotational speed difference and the phase difference increase, the time required for the blade to reach a steady state is longer. When the phase difference is too large, the electromechanical coupling can no longer make the joint excitation device appear self-synchronizing phenomenon, so that the value of the phase difference develops toward a fixed value (not equal to 0, and the blade vibration disorder is serious, at this time, the effect of electromechanical coupling must be eliminated. The research results provide theoretical basis for the subsequent decoupling control algorithm and synchronization control strategy, and have good application value.

  17. An accelerated exposure and testing apparatus for building joint sealants.

    Science.gov (United States)

    White, C C; Hunston, D L; Tan, K T; Hettenhouser, J; Garver, J D

    2013-09-01

    The design, fabrication, and implementation of a computer-controlled exposure and testing apparatus for building joint sealants are described in this paper. This apparatus is unique in its ability to independently control and monitor temperature, relative humidity, ultraviolet (UV) radiation, and mechanical deformation. Each of these environmental factors can be controlled precisely over a wide range of conditions during periods of a month or more. Moreover, as controlled mechanical deformations can be generated, in situ mechanical characterization tests can be performed without removing specimens from the chamber. Temperature and humidity were controlled during our experiments via a precision temperature regulator and proportional mixing of dry and moisture-saturated air; while highly uniform UV radiation was attained by attaching the chamber to an integrating sphere-based radiation source. A computer-controlled stepper motor and a transmission system were used to provide precise movement control. The reliability and effectiveness of the apparatus were demonstrated on a model sealant material. The results clearly show that this apparatus provides an excellent platform to study the long-term durability of building joint sealants.

  18. Movement of the sacroiliac joint during the Active Straight Leg Raise test in patients with long-lasting severe sacroiliac joint pain.

    Science.gov (United States)

    Kibsgård, Thomas J; Röhrl, Stephan M; Røise, Olav; Sturesson, Bengt; Stuge, Britt

    2017-08-01

    The Active Straight Leg Raise is a functional test used in the assessment of pelvic girdle pain, and has shown to have good validity, reliability and responsiveness. The Active Straight Leg Raise is considered to examine the patients' ability to transfer load through the pelvis. It has been hypothesized that patients with pelvic girdle pain lack the ability to stabilize the pelvic girdle, probably due to instability or increased movement of the sacroiliac joint. This study examines the movement of the sacroiliac joints during the Active Straight Leg Raise in patients with pelvic girdle pain. Tantalum markers were inserted in the dorsal sacrum and ilium of 12 patients with long-lasting pelvic girdle pain scheduled for sacroiliac joint fusion surgery. Two to three weeks later movement of the sacroiliac joints during the Active Straight Leg Raise was measured with radiostereometric analysis. Small movements were detected. There was larger movement of the sacroiliac joint of the rested leg's sacroiliac joint compared to the lifted leg's side. A mean backward rotation of 0.8° and inward tilt of 0.3° were seen in the rested leg's sacroiliac joint. The movements of the sacroiliac joints during the Active Straight Leg Raise are small. There was a small backward rotation of the innominate bone relative to sacrum on the rested leg's side. Our findings contradict an earlier understanding that a forward rotation of the lifted leg's innominate occur while performing the Active Straight Leg Raise. Copyright © 2017. Published by Elsevier Ltd.

  19. Fabrication, testing and analysis of steel/composite DLS adhesive joints

    DEFF Research Database (Denmark)

    Nashim, S.; Nisar, J.; Tsouvalis, N.

    2009-01-01

    0/90 WR GFRP and 0/90 UD CFRP laminates and steel. The focus here is on CFRP/steel joint due to availability of test data. The thickness of the outer adherend varies from 3 mm to 6 mm. Shear overlaps of 25-200mm were considered. The overall objectives are (i) to assess the quality of the standard...

  20. Summary of LaRC 2-inch Erectable Joint Hardware Heritage Test Data

    Science.gov (United States)

    Dorsey, John T.; Watson, Judith J.

    2016-01-01

    As the National Space Transportation System (STS, also known as the Space Shuttle) went into service during the early 1980's, NASA envisioned many missions of exploration and discovery that could take advantage of the STS capabilities. These missions included: large orbiting space stations, large space science telescopes and large spacecraft for manned missions to the Moon and Mars. The missions required structures that were significantly larger than the payload volume available on the STS. NASA Langley Research Center (LaRC) conducted studies to design and develop the technology needed to assemble the large space structures in orbit. LaRC focused on technology for erectable truss structures, in particular, the joint that connects the truss struts at the truss nodes. When the NASA research in large erectable space structures ended in the early 1990's, a significant amount of structural testing had been performed on the LaRC 2-inch erectable joint that was never published. An extensive set of historical information and data has been reviewed and the joint structural testing results from this historical data are compiled and summarized in this report.

  1. Testing the permeability and corrosion resistance of micro-mechanically interlocked joints

    DEFF Research Database (Denmark)

    Byskov-Nielsen, Jeppe; Holm, Allan Hjarbæk; Højsholt, Rune

    2011-01-01

    Micro-mechanical interlocking (MMI) can be applied to create new and interesting composite materials. We have employed laser structuring to achieve MMI between stainless steel and plastic with extremely high joint strength. However, the water permeability and corrosion resistance of the joint must...... is conducted. The permeability seems to be consistent with the Hagen–Poiseuille equation independent of the laser structuring technique and is orders of magnitudes larger than the diffusion rate through the plastic. Two different types of corrosion tests have been undertaken, and we show that care must...... be taken in order not to degrade the corrosion resistance of the sample to an unacceptable level....

  2. Laboratory testing of joints between windows and highly insulated cavity walls. Investigations of tightness against rain and wind

    Energy Technology Data Exchange (ETDEWEB)

    Kjaer, A

    1983-10-01

    In the Danish energy research programme, 1EFP 80, a number of laboratory tests have been carried out on models of highly insulated cavity brick walls in order to study rain- and wind tightness of the joints between windows and such walls. Tests have been carried out with joints tightened only with a rain barrier as well as with joints according to the two stage joint principle. In the exterior part of the joint has in both cases been used a mortar, and expanding gasket, an EPDM-profile and wooden battens. Further an experiment has been carried out on a plastic window, where mastic was used as well in the exterior as the interior part of the joint. The findings were that a two-stage joint gives the best performance as well regarding air tightness as rain tightness. Further the experiments have shown that a window frame should have a depth of at least 90 mm in order to design a joint between window and wall, which is satisfactory as well regarding thermal insulation as resistance to rain and wind.

  3. Together I Can! Joint Attention Boosts 3- to 4-Year-Olds' Performance in a Verbal False-Belief Test.

    Science.gov (United States)

    Psouni, Elia; Falck, Andreas; Boström, Leni; Persson, Martin; Sidén, Lisa; Wallin, Maria

    2018-04-20

    Effects of joint attention were addressed on 3- to 4-year-olds' performance in a verbal false-Belief Test (FBT), featuring the experimenter as co-watcher rather than narrator. In two experiments, children (N = 183) watched a filmed-FBT jointly with a test leader, disjointed from a test leader, or alone. Children attending jointly with a test leader were more likely to pass the FBT compared with normative data and to spontaneously recall information indicating false-belief understanding, suggesting that joint attention strengthens the plausibility of the FBT and renders plot-critical information more salient. In a third experiment (N = 59), results were replicated using a typical, image-based FBT. Overall findings highlight the profound impact of experimenter as social context in verbal FBTs, and link recall of specific story features to false-belief understanding. © 2018 Society for Research in Child Development.

  4. Head waves in ultrasonic testing. Physical principle and application to welded joint testing

    International Nuclear Information System (INIS)

    Wustenberg, H.; Erhard, A.

    1984-01-01

    A head wave sensor is developed from distinct emitter and receiver sensors using longitudinal waves under a 70 0 incidence. These heat wave sensors present a high sensitivity for underlying cracks and are not influenced by surface accidents like liquid drops or welding projection. They are multi mode sensors emitting simultaneously longitudinal head waves, a main longitudinal lobe and a transverse wave with a maximum at about 38 0 . This wave combination can be used for automatic testing of welded joints even with austenitic materials for defect detection near internal or external surfaces. This process can substitute or complete liquid penetrant inspection or magnetic inspection for testing pipes (13 references are given) [fr

  5. R-ES-ONANCE--INo-ve-mber

    Indian Academy of Sciences (India)

    All of us learn in school, the method of 'completing squares' to solve quadratic ... This was first developed by ... every element of G is expressible as a product of elements from S and ... Of course, a finite group is finitely g~nerated. But, there are ...

  6. Welding of metallic fuel elements for the irradiation test in JOYO. Preliminary tests and welding execution tests (Joint research)

    International Nuclear Information System (INIS)

    Kikuchi, Hironobu; Nakamura, Kinya; Iwai, Takashi; Arai, Yasuo

    2009-10-01

    Irradiation tests of metallic fuels elements in fast test reactor JOYO are planned under the joint research of Japan Atomic Energy Agency (JAEA) and Central Research Institute of Electric Power Industry (CRIEPI). Six U-Pu-Zr fuel elements clad with ferritic martensitic steel are fabricated in Plutonium Fuel Research Facility (PFRF) of JAEA-Oarai for the first time in Japan. In PFRF, the procedures of fabrication of the fuel elements were determined and the test runs of the equipments were carried out before the welding execution tests for the fuel elements. Test samples for confirming the welding condition between the cladding tube and top and bottom endplugs were prepared, and various test runs were carried out before the welding execution tests. As a result, the welding conditions were finalized by passing the welding execution tests. (author)

  7. Minimum joint space width (mJSW) of patellofemoral joint on standing ''skyline'' radiographs: test-retest reproducibility and comparison with quantitative magnetic resonance imaging (qMRI)

    Energy Technology Data Exchange (ETDEWEB)

    Simoni, Paolo; Jamali, Sanaa; Alvarez Miezentseva, Victoria [CHU de Liege, Diagnostic Imaging Departement, Domanine du Sart Tilman, Liege (Belgium); Albert, Adelin [CHU de Liege, Biostatistics Departement, Domanine du Sart Tilman, Liege (Belgium); Totterman, Saara; Schreyer, Edward; Tamez-Pena, Jose G. [Qmetrics Technologies, Rochester, NY (United States); Zobel, Bruno Beomonte [Campus Bio-Medico University, Diagnostic Imaging Departement, Rome (Italy); Gillet, Philippe [CHU de Liege, Orthopaedic surgery Department, Domanine du Sart Tilman, Liege (Belgium)

    2013-11-15

    To assess the intraobserver, interobserver, and test-retest reproducibility of minimum joint space width (mJSW) measurement of medial and lateral patellofemoral joints on standing ''skyline'' radiographs and to compare the mJSW of the patellofemoral joint to the mean cartilage thickness calculated by quantitative magnetic resonance imaging (qMRI). A couple of standing ''skyline'' radiographs of the patellofemoral joints and MRI of 55 knees of 28 volunteers (18 females, ten males, mean age, 48.5 {+-} 16.2 years) were obtained on the same day. The mJSW of the patellofemoral joint was manually measured and Kellgren and Lawrence grade (KLG) was independently assessed by two observers. The mJSW was compared to the mean cartilage thickness of patellofemoral joint calculated by qMRI. mJSW of the medial and lateral patellofemoral joint showed an excellent intraobserver agreement (interclass correlation (ICC) = 0.94 and 0.96), interobserver agreement (ICC = 0.90 and 0.95) and test-retest agreement (ICC = 0.92 and 0.96). The mJSW measured on radiographs was correlated to mean cartilage thickness calculated by qMRI (r = 0.71, p < 0.0001 for the medial PFJ and r = 0.81, p < 0.0001 for the lateral PFJ). However, there was a lack of concordance between radiographs and qMRI for extreme values of joint width and KLG. Radiographs yielded higher joint space measures than qMRI in knees with a normal joint space, while qMRI yielded higher joint space measures than radiographs in knees with joint space narrowing and higher KLG. Standing ''skyline'' radiographs are a reproducible tool for measuring the mJSW of the patellofemoral joint. The mJSW of the patellofemoral joint on radiographs are correlated with, but not concordant with, qMRI measurements. (orig.)

  8. Can joint sound assess soft and hard endpoints of the Lachman test?: A preliminary study.

    Science.gov (United States)

    Hattori, Koji; Ogawa, Munehiro; Tanaka, Kazunori; Matsuya, Ayako; Uematsu, Kota; Tanaka, Yasuhito

    2016-05-12

    The Lachman test is considered to be a reliable physical examination for anterior cruciate ligament (ACL) injury. Patients with a damaged ACL demonstrate a soft endpoint feeling. However, examiners judge the soft and hard endpoints subjectively. The purpose of our study was to confirm objective performance of the Lachman test using joint auscultation. Human and porcine knee joints were examined. Knee joint sound during the Lachman test (Lachman sound) was analyzed by fast Fourier transformation. As quantitative indices of Lachman sound, the peak sound as the maximum relative amplitude (acoustic pressure) and its frequency were used. The mean Lachman peak sound for healthy volunteer knees was 86.9 ± 12.9 Hz in frequency and -40 ± 2.5 dB in acoustic pressure. The mean Lachman peak sound for intact porcine knees was 84.1 ± 9.4 Hz and -40.5 ± 1.7 dB. Porcine knees with ACL deficiency had a soft endpoint feeling during the Lachman test. The Lachman peak sounds of porcine knees with ACL deficiency were dispersed into four distinct groups, with center frequencies of around 40, 160, 450, and 1600. The Lachman peak sound was capable of assessing soft and hard endpoints of the Lachman test objectively.

  9. Assessment of NDE Methods on Inspection of HDPE Butt Fusion Piping Joints for Lack of Fusion with Validation from Mechanical Testing

    International Nuclear Information System (INIS)

    Anderson, Michael T.; Cinson, Anthony D.; Crawford, Susan L.; Doctor, Steven R.; Moran, Traci L.; Watts, Michael W.

    2010-01-01

    Studies at the Pacific Northwest National Laboratory (PNNL) in Richland, Washington, are being conducted to evaluate nondestructive examinations (NDE) coupled with mechanical testing of butt fusion joints in high-density polyethylene (HDPE) pipe for assessing lack of fusion. The work provides information to the U.S. Nuclear Regulatory Commission (NRC) on the effectiveness of volumetric inspection techniques of HDPE butt fusion joints in Section III, Division 1, Class 3, buried piping systems in nuclear power plants. This paper describes results from preliminary assessments using ultrasonic and microwave nondestructive techniques and mechanical testing with the high-speed tensile impact test and the side-bend test for determining joint integrity. A series of butt joints were fabricated in 3408, 12-in. IPS DR-11 HDPE material by varying the fusion parameters to create good joints and joints containing a range of lack-of-fusion conditions. Six of these butt joints were volumetrically examined with time-of-flight diffraction (TOFD), phased-array (PA) ultrasound, and the Evisive microwave system. The outer-diameter weld beads were removed for the microwave inspection. In two of the four pipes, both the outer and inner weld beads were removed and the pipe joints re-evaluated. The pipes were sectioned and the joints destructively evaluated with the side-bend test by cutting portions of the fusion joint into slices that were planed and bent. The last step in this limited study will be to correlate the fusion parameters, nondestructive, and destructive evaluation results to validate the effectiveness of what each NDE technology detects and what each does not detect. The results of the correlation will be used in identifying any future work that is needed.

  10. Testing of the shopprimer’s influence on the quality of welded joint

    Directory of Open Access Journals (Sweden)

    T. Šolić

    2017-01-01

    Full Text Available This paper presents the process of preparing the surface of construction material and applying the temporary protection that refers to the two-component epoxy workshop primer (shopprimer in order to perform testing of its influence on mechanical properties of the weld. Testing of mechanical properties of welds after welding proved that there were no negative influences of the protective coating on the quality of welded joint.

  11. Ultrasonic testing standard of fusion joint for polythylene(PE) pipeline

    International Nuclear Information System (INIS)

    Lee, Euy Jong; Hur, Sam Suk; Chae, Gug Byeong

    2006-01-01

    The polyethylene(PE) pipes are widely used to transport city gas worldwide with steel pipes. Generally, Steel pipe are used for high pressure line and PE pipe for low pressure line whose pressure is less than 4 kg/m 2 . The steel pipe line are subject to 100 percent Radiographic Testing(RT) during installation stage, on the contrary, there has been no the established testing method for the welding fusion joint of polyethylene pipes, so all quality control is limited only Visual Testing(VT) or management of Fusion welding equipment. Even though PE pipeline is exposed to lower pressure than steel pipeline, the gas leakage from PE pipe may result in almost the same serious consequence from steel pipeline. So, it is necessary to develop the reliable testing standard for PE pipeline from the point of view of NDT engineers.

  12. Investigation of Be/Cu joints via HHF tests of small-scale mockups

    Energy Technology Data Exchange (ETDEWEB)

    Giniatulin, R.; Gervash, A.; Komarov, V.L.; Litunovsky, N.; Mazul, I.; Yablokov, N. [Efremov Inst., St. Petersburg (Russian Federation)

    1998-01-01

    Beryllium-copper (Be/Cu) joints in divertor components work under cyclic heat loads. To develop reliable joints small-scale mockups are fabricated by divertor technologies and tested under the divertor conditions. One of the critical damaging factors that exist in the divertor and have to be simulated is thermocyclic heat loads in the range of 1-15 MW/m{sup 2}. This work presents the divertor mockups that have beryllium tiles with different dimensions (5 x 5 - 44 x 44) mm{sup 2} brazed with copper alloy heat sink. The electron beam was used to braze these mockups so as to decrease the formation of brittle intermetallic layers. The description of mockups design, geometry of armour tiles and fabrication techniques are presented in the paper. The results of screening and thermocyclic tests of these mockups in the heat flux range of 2-12 MW/m{sup 2} with a number of cycles {approx}10{sup 3} are presented. The results of metallographic analysis are also presented. The results of fabrication and testing with small-scale mockups for first wall application are also described. (author)

  13. Model Testing of Forces in the Reflector Joint and Mooring Forces on Wave Dragon

    DEFF Research Database (Denmark)

    Gilling, Lasse; Kofoed, Jens Peter; Tedd, James

    This report aims to present the results of a test series analysing the forces in the redesigned reflector joint and the forces in the main mooring link. The resluts presented are intended to be used by WD project partners, for the design and construction of the joint on the prototype Wave Dragon...... at Nissum Bredning and for future North Sea scale Wave Dragon. Lengths, forces and other dimentions presented are scaled to the North sea Wave Dragon unless otherwise specified....

  14. Test the Overall Significance of p-values by Using Joint Tail Probability of Ordered p-values as Test Statistic

    OpenAIRE

    Fang, Yongxiang; Wit, Ernst

    2008-01-01

    Fisher’s combined probability test is the most commonly used method to test the overall significance of a set independent p-values. However, it is very obviously that Fisher’s statistic is more sensitive to smaller p-values than to larger p-value and a small p-value may overrule the other p-values and decide the test result. This is, in some cases, viewed as a flaw. In order to overcome this flaw and improve the power of the test, the joint tail probability of a set p-values is proposed as a ...

  15. Reproducibility of pop-ins in laboratory testing of welded joints

    Directory of Open Access Journals (Sweden)

    Berejnoi C.

    2000-01-01

    Full Text Available The pop-in phenomenon, quite common in fracture mechanics tests of welded joints, corresponds to a brittle crack initiation grown from a local brittle zone (LBZ that is arrested in reaching the higher toughness material that surrounds this LBZ. A methodology to obtain a high percentage of pop-in occurrence in laboratory testing is necessary to study the pop-in significance. Such a method is introduced in this work and includes the consumable combination and welding procedures for the SMAW welding process to generate artificial LBZ. In order to find out the influence of the loading state upon the pop-in phenomenon, laboratory CTOD tests were performed using two specimen configurations: some single edge-notched specimens were loaded on a three-point bending (SE(B fixture while others were tested in tensile load (SE(T. A higher frequency of pop-in occurrence was observed in the SE(B geometry.

  16. An activated energy approach for accelerated testing of the deformation of UHMWPE in artificial joints.

    Science.gov (United States)

    Galetz, Mathias Christian; Glatzel, Uwe

    2010-05-01

    The deformation behavior of ultrahigh molecular polyethylene (UHMWPE) is studied in the temperature range of 23-80 degrees C. Samples are examined in quasi-static compression, tensile and creep tests to determine the accelerated deformation of UHMWPE at elevated temperatures. The deformation mechanisms under compression load can be described by one strain rate and temperature dependent Eyring process. The activation energy and volume of that process do not change between 23 degrees C and 50 degrees C. This suggests that the deformation mechanism under compression remains stable within this temperature range. Tribological tests are conducted to transfer this activated energy approach to the deformation behavior under loading typical for artificial knee joints. While this approach does not cover the wear mechanisms close to the surface, testing at higher temperatures is shown to have a significant potential to reduce the testing time for lifetime predictions in terms of the macroscopic creep and deformation behavior of artificial joints. Copyright 2010. Published by Elsevier Ltd.

  17. Laboratory characterization of rock joints

    International Nuclear Information System (INIS)

    Hsiung, S.M.; Kana, D.D.; Ahola, M.P.; Chowdhury, A.H.; Ghosh, A.

    1994-05-01

    A laboratory characterization of the Apache Leap tuff joints under cyclic pseudostatic and dynamic loads has been undertaken to obtain a better understanding of dynamic joint shear behavior and to generate a complete data set that can be used for validation of existing rock-joint models. Study has indicated that available methods for determining joint roughness coefficient (JRC) significantly underestimate the roughness coefficient of the Apache Leap tuff joints, that will lead to an underestimation of the joint shear strength. The results of the direct shear tests have indicated that both under cyclic pseudostatic and dynamic loadings the joint resistance upon reverse shearing is smaller than that of forward shearing and the joint dilation resulting from forward shearing recovers during reverse shearing. Within the range of variation of shearing velocity used in these tests, the shearing velocity effect on rock-joint behavior seems to be minor, and no noticeable effect on the peak joint shear strength and the joint shear strength for the reverse shearing is observed

  18. Model Test Research on the End Bearing Behavior of the Large-Diameter Cast-in-Place Concrete Pile for Jointed Rock Mass

    Directory of Open Access Journals (Sweden)

    Jingwei Cai

    2016-01-01

    Full Text Available For large-diameter, cast-in-place concrete piles, the end bearing capacity of a single pile is affected by discontinuous surfaces that exist in natural rock masses when the bearing layer of the pile end is located in the rock layer. In order to study the influence of the jointed dip angle on the bearing characteristics of the pile end, the discrete element models are adopted to simulate the mechanical characteristics of the jointed rock masses, and the model tests of the failure mode of the jointed rock masses were also designed. The results of the numerical calculations and modeling tests show that the joints, which have a filtering effect on the internal stress of the bedrock located at the pile end, change the load transferring paths. And the failure mode of the jointed rock foundation also changes as jointed dip angle changes. The rock located at the pile end generally presents a wedge failure mode. In addition, the Q-S curves obtained by model tests show that the ultimate end bearing capacity of a single pile is influenced by the jointed dip angle. The above results provide an important theoretical basis for how to correctly calculate end resistance for a cast-in-place concrete pile.

  19. Joining of Materials with Diferent Properties Through Submerged Arc Welding Process and Destructive and Non-Destructive Testing of the Joints

    Directory of Open Access Journals (Sweden)

    Yakup Kaya

    2013-01-01

    Full Text Available In this study, X60, X65 and X70 steels used in petroleum and natural gas pipeline were joined with Submerged Arc Welding by using different type of welding fluxes (LN761 and P223 and wires (S1 and S2Mo. Initially, visual and radiographic inspection techniques were subjected to welded joints for determining surface and subsurface defects. After that, spectral analyses were carried out in order to determine the compositions of wire-flux-base metal on the joints. Impact toughness test were performed for determining toughness properties the joints. Furthermore, hardness and microstructure studies were also carried out on the samples. As a result of the visual and radiographic inspection on the welded samples, there were no weld defects on joints were observed. It was clearly understood that carbon ratio in the compositions of weld metal higher than base metal but lower than filler metal in terms of spectral analyses results. According to impact toughness test results, the joints obtained by using S2Mo welding wire and P223 welding flux had better impact toughness value than the joints obtained by S1 welding wire and LN 761 welding flux. With respect to hardness test, the highest hardness values were measured on weld metal. When the microstructure images were examined, it is clearly understood that similar images for all the joints were shown adjacent zones to weld metals heat affected zones and welding boundary, due to heat input constant.

  20. Revised analysis of the Transition Joint Life Test

    Energy Technology Data Exchange (ETDEWEB)

    Sartory, W K

    1984-07-01

    The Transition Joint Life Test was performed by General Electric and the Energy Technology Engineering Center and was analyzed earlier by General Electric. Because of later developments in analysis techniques and in our understanding of the stress behavior near a dissimilar metal weldment, agreement was reached between General Electric and Oak Ridge National Laboratory`s High-Temperature Structural Design program that a more up-to-date analysis was needed. This report presents results of a new analysis incorporating modified mechanical properties, revised constitutive equations, and a more refined finite element grid. The structural life prediction of the present report is quite conservative (approximately 3 cycles of predicted life compared to 12 to 25 cycles of measured life), whereas the earlier General Electric analysis was underconservative by a similar factor.

  1. Ultrasonic test of carbon composite/copper joints in the ITER divertor

    International Nuclear Information System (INIS)

    Roccella, S.; Cacciotti, E.; Candura, D.; Mancini, A.; Pizzuto, A.; Reale, A.; Tatì, A.; Visca, E.

    2013-01-01

    Highlights: • ENEA developed and tested a specimen for the simulation of defects at the interface between CFC and copper. • The use of an ultrasonic technique properly set permitted to highlight and size with high accuracy the defects. • The technology developed could be employed successfully in the production of these components for high heat flux applications. -- Abstract: The vertical targets of the ITER divertor consist of high flux units (HFU) actively cooled: CuCrZr tubes armoured by tungsten and carbon/carbon fibre composite (CFC). The armour is obtained with holed parallelepiped blocks, called monoblocks, previously prepared and welded onto the tubes by means diffusion bonding. The monoblock preparation consists in the casting of a layer of copper oxygen free (Cu OFHC) inside the monoblock hole. Each HFU is covered with more than 100 monoblocks that have to be joined simultaneously to the tube. Therefore, it is very important to individuate any defects present in the casting of Cu OFHC or at the interface with the CFC before the monoblocks are installed on the units. This paper discusses the application of non-destructive testing by ultrasound (US) method for the control of the joining interfaces between CFC monoblocks and Cu OFHC, before the brazing on the CrCrZr tube. In ENEA laboratory an ultrasonic technique (UT) suitable for the control of these joints with size and geometry according to the ITER specifications has been developed and widely tested. Real defects in this type of joints are, however, still hardly detected by UT. The CFC surface has to be machined to improve the mechanical strength of the joint. This results in a surface not perpendicular to the ultrasonic wave. Moreover, CFC is characterized by high acoustic attenuation of the ultrasonic wave and then it is not easy to get information regarding the Cu/CFC bonding. Nevertheless, the UT sharpness and simplicity pushes to perform some further study. With this purpose, a sample with

  2. Ultrasonic test of carbon composite/copper joints in the ITER divertor

    Energy Technology Data Exchange (ETDEWEB)

    Roccella, S., E-mail: selanna.roccella@enea.it [Associazione ENEA-Euratom sulla Fusione, C.R. Frascati, 00044 Frascati, RM (Italy); Cacciotti, E. [Associazione ENEA-Euratom sulla Fusione, C.R. Frascati, 00044 Frascati, RM (Italy); Candura, D. [Ansaldo Nucleare S.p.A., C. so F.M. Perrone 25, 16152 Genoa (Italy); Mancini, A.; Pizzuto, A.; Reale, A. [Associazione ENEA-Euratom sulla Fusione, C.R. Frascati, 00044 Frascati, RM (Italy); Tatì, A. [Associazione Euratom-ENEA sulla Fusione, C.R. Casaccia, Via Anguillarese 301, 00123 Santa Maria di Galeria, RM (Italy); Visca, E. [Associazione ENEA-Euratom sulla Fusione, C.R. Frascati, 00044 Frascati, RM (Italy)

    2013-10-15

    Highlights: • ENEA developed and tested a specimen for the simulation of defects at the interface between CFC and copper. • The use of an ultrasonic technique properly set permitted to highlight and size with high accuracy the defects. • The technology developed could be employed successfully in the production of these components for high heat flux applications. -- Abstract: The vertical targets of the ITER divertor consist of high flux units (HFU) actively cooled: CuCrZr tubes armoured by tungsten and carbon/carbon fibre composite (CFC). The armour is obtained with holed parallelepiped blocks, called monoblocks, previously prepared and welded onto the tubes by means diffusion bonding. The monoblock preparation consists in the casting of a layer of copper oxygen free (Cu OFHC) inside the monoblock hole. Each HFU is covered with more than 100 monoblocks that have to be joined simultaneously to the tube. Therefore, it is very important to individuate any defects present in the casting of Cu OFHC or at the interface with the CFC before the monoblocks are installed on the units. This paper discusses the application of non-destructive testing by ultrasound (US) method for the control of the joining interfaces between CFC monoblocks and Cu OFHC, before the brazing on the CrCrZr tube. In ENEA laboratory an ultrasonic technique (UT) suitable for the control of these joints with size and geometry according to the ITER specifications has been developed and widely tested. Real defects in this type of joints are, however, still hardly detected by UT. The CFC surface has to be machined to improve the mechanical strength of the joint. This results in a surface not perpendicular to the ultrasonic wave. Moreover, CFC is characterized by high acoustic attenuation of the ultrasonic wave and then it is not easy to get information regarding the Cu/CFC bonding. Nevertheless, the UT sharpness and simplicity pushes to perform some further study. With this purpose, a sample with

  3. Nondestructive evaluation of adhesive joints by C-scan ultrasonic testing

    International Nuclear Information System (INIS)

    Zeighami, Mehdi; Honarvar, Farhang

    2009-01-01

    Evaluation of the quality of adhesive bonding is an important issue in many industries who incorporate adhesive joints in their products. Over the past few decades, numerous acoustical techniques have been developed for nondestructive testing (NDT) of adhesively bonded joints. Among these techniques, the ultrasonic pulse-echo method is the most promising means for inspection of adhesive bonds. In practice, due to low impedance matching between adhesive and metal, the discrimination of a good bond from a bad bond is difficult. The low impedance matching also results in low contrast between perfect and disbanded zone in a C-scan image. In this paper, the quality of the interface between aluminum and epoxy is investigated by using an in-house built ultrasonic C-scan system. Two adhesion indices are proposed for producing C-scan images. To verify the capability of these indices, an adhesively bonded sample was fabricated using aluminum plates and epoxy. An artificial defect was implanted in the first interface of the specimens. The C-scan measurement prepared based on the proposed indices was able to reveal the defect much better than the C-scan image prepared by conventional approach. (author)

  4. Creep of timber joints

    NARCIS (Netherlands)

    Van de Kuilen, J.W.G.

    2008-01-01

    A creep analysis has been performed on nailed, toothed-plates and split-ring joints in a varying uncontrolled climate. The load levels varied between 30% and 50% of the average ultimate short term strength of these joints, tested in accordance with ISO 6891. The climate in which the tests were

  5. Analysis on Adhesively-Bonded Joints of FRP-steel Composite Bridge under Combined Loading: Arcan Test Study and Numerical Modeling

    Directory of Open Access Journals (Sweden)

    Xu Jiang

    2016-01-01

    Full Text Available The research presented in this paper is an experimental study and numerical analysis on mechanical behavior of the adhesively-bonded joint between FRP sandwich bridge deck and steel girder. Generally, there are three typical stress states in the adhesively-bonded joint: shear stress, tensile stress, and combination of both. To realize these stress states in the adhesively-bonded joint during tests, a specific loading device is developed with the capacity of providing six different loading angles, which are 0°(pure tension, 18°, 36°, 54°, 72° and 90°(pure shear. Failure modes of adhesively-bonded joints are investigated. It indicates that, for the pure shear loading, the failure mode is the cohesive failure (near the interface between the adhesive layer and the steel support in the adhesive layer. For the pure tensile and combined loading conditions, the failure mode is the combination of fiber breaking, FRP delamination and interfacial adhesion failure between the FRP sandwich deck and the adhesive layer. The load-bearing capacities of adhesive joints under combined loading are much lower than those of the pure tensile and pure shear loading conditions. According to the test results of six angle loading conditions, a tensile/shear failure criterion of the adhesively-bonded joint is obtained. By using Finite Element (FE modeling method, linear elastic simulations are performed to characterize the stress distribution throughout the adhesively-bonded joint.

  6. Testing of quality of welded joints using heavy-current pulse X-ray apparatuses

    International Nuclear Information System (INIS)

    Gusev, E.A.; Firstov, V.G.

    1988-01-01

    The possibilities of carrying out of radiographic and electroradiographic testing of quality of welded joints using heavy-current pulse X-ray apparatuses under the mode of single pulses are shown. Basic quantitative characteristics of radiographic testing permitting to detect the focus distance, sensitivity behaviour and optical density of image are presented. Peculiarities of electroradiographic image formation under the mode of single pulses of nanosecond range are analysed. The outlook of heavy-current pulse X-ray apparatus application under the mode of single pulses in industry is estimated

  7. Development of an above-knee prosthesis equipped with a microcomputer-controlled knee joint: first test results.

    Science.gov (United States)

    Aeyels, B; Peeraer, L; Vander Sloten, J; Van der Perre, G

    1992-05-01

    The shortcomings of conventional above-knee prostheses are due to their lack of adaptive control. Implementation of a microcomputer controlling the knee joint in a passive way has been suggested to enhance the patient's gait comfort, safety and cosmesis. This approach was used in the design of a new prosthetic system for the above-knee amputee, and tested on one patient. The knee joint of a conventional, modular prosthesis was replaced by a knee joint mechanism, equipped with a controllable brake on the knee joint axis. Sensors and a microcomputer were added, keeping the system self-contained. The modularity of the design permits the use of an alternative, external, PC-based control unit, emulating the self-contained one, and offering extended data monitoring and storage facilities. For both units an operating environment was written, including sensor/actuator interfacing and the implementation of a real-time interrupt, executing the control algorithm. A double finite state approach was used in the design of the control algorithm. On a higher level, the mode identification algorithm reveals the patient's intent. Within a specific mode (lower level), the relevant mode control algorithm looks for the current phase within the gait cycle. Within a particular phase, a specific simple control action with the brake replaces normal knee muscle activity. Tests were carried out with one prosthetic patient using a basic control algorithm for level walking, allowing controlled knee flexion during stance phase. The technical feasibility of such a concept is illustrated by the test results, even though only flexion during early stance phase was controlled during the trials.(ABSTRACT TRUNCATED AT 250 WORDS)

  8. Objective Assessment of Joint Stiffness: A Clinically Oriented Hardware and Software Device with an Application to the Shoulder Joint.

    Science.gov (United States)

    McQuade, Kevin; Price, Robert; Liu, Nelson; Ciol, Marcia A

    2012-08-30

    Examination of articular joints is largely based on subjective assessment of the "end-feel" of the joint in response to manually applied forces at different joint orientations. This technical report aims to describe the development of an objective method to examine joints in general, with specific application to the shoulder, and suitable for clinical use. We adapted existing hardware and developed laptop-based software to objectively record the force/displacement behavior of the glenohumeral joint during three common manual joint examination tests with the arm in six positions. An electromagnetic tracking system recorded three-dimensional positions of sensors attached to a clinician examiner and a patient. A hand-held force transducer recorded manually applied translational forces. The force and joint displacement were time-synchronized and the joint stiffness was calculated as a quantitative representation of the joint "end-feel." A methodology and specific system checks were developed to enhance clinical testing reproducibility and precision. The device and testing protocol were tested on 31 subjects (15 with healthy shoulders, and 16 with a variety of shoulder impairments). Results describe the stiffness responses, and demonstrate the feasibility of using the device and methods in clinical settings.

  9. Radiographic and ultrasonic testings of welded joints of 6063 aluminium alloy

    International Nuclear Information System (INIS)

    Oliveira e Silva Mury, A.G. de.

    1980-05-01

    A study on evaluation of weld defects in aluminium butt joints was made in a comparative way through the radiographic and ultrasonic testing. This work was conducted with pipes 5 IPS (6,35 mm thickness) of 6063 aluminium alloy, circumferential TIG welded, due to the difficulty on performing non-destructive testing with this schedule. It was concluded thta ultrasonic testing has adequate sensitivity when setting gain adjustment is made with aid of a reference curve constructed by using a Reference Block (among others studied) with 1,5 mm dia. Hole as reference reflector, and a 5 MHz angle beam search-unit. In this case the ultrasonic testing is more accurate than radiographic testing to detect planar defects like lack of fusion and lack of penetration. Defect sizing by ultrasonic methods employed were 6 and 20 dB drop methods. In spite of your observed limitations concerning the establishment of the real size of defects, the procedure applied was precise for locate and define the weld defects that where found in this study. (author) [pt

  10. Failure conditions from push-out tests of a steel-concrete joint: experimental results

    Czech Academy of Sciences Publication Activity Database

    Helincks, P.; De Corte, W.; Klusák, Jan; Seitl, Stanislav; Boel, V.; De Schutter, G.

    488-489, - (2012), s. 714-717 ISSN 1013-9826. [International Conference on Fracture and Damage Mechanics - FDM 2011 /10./. Dubrovník, 19.09.2011-21.09.2011] R&D Projects: GA ČR GAP108/10/2049 Institutional research plan: CEZ:AV0Z20410507 Keywords : steel-concrete joint * push-out test * shear bond strength Subject RIV: JL - Materials Fatigue, Friction Mechanics

  11. Design and construction of a block test in closely jointed rock

    International Nuclear Information System (INIS)

    Black, M.T.; Cramer, M.L.

    1983-06-01

    The Basalt Waste Isolation Project developed a large-scale block test to investigate the in-situ deformational response of a basalt rock mass. The test was designed and installed into the vertical rib (wall) of a tunnel to examine the response of basalt both in a parallel and perpendicular mode to the basalt columns. The salient challenge confronting the design and development of the test was a lack of documented experience for testing into a vertical wall. Information was available for testing in a horizontal surface. The major tasks involved in the implementation of this test included flat-jack slot drilling, instrumentation hole drilling, cable anchor hole drilling, flat-jack installation, monitoring instrumentation installation, and cable anchor installation. Drilling in the closely jointed and fractured rock mass required extreme care to prevent unraveling of the columnar structure and to minimize the disturbance of the section to be tested. The adaptation of a high-strength cable anchor system to the space limitations of the test configuration and the design and implementation of an optical deformation monitoring device capable of achieving a measurement precision of 30 μm required equal innovation. Construction of the test facility was successfully completed on schedule in approx. 25 wk

  12. Fatigue Life of High-Strength Steel Offshore Tubular Joints

    DEFF Research Database (Denmark)

    Petersen, Rasmus Ingomar; Agerskov, Henning; Lopez Martinez, Luis

    1996-01-01

    In the present investigation, the fatigue life of tubular joints in offshore steel structures is studied. Two test series on full-scale tubular joints have been carried through. One series was on joints in conventional offshore structural steel, and the other series was on joints in high-strength......In the present investigation, the fatigue life of tubular joints in offshore steel structures is studied. Two test series on full-scale tubular joints have been carried through. One series was on joints in conventional offshore structural steel, and the other series was on joints in high......-strength steel with a yield stress of 820-830 MPa and with high weldability and toughness properties. The test specimens of both series had the same geometry. The present report concentrates on the results obtained in the investigation on the high-strength steel tubular joints.The test specimens were fabricated...... from Ø 324-610 mm tubes, and the joints were loaded in in-plane bending. Both fatigue tests under constant amplitude loading and tests with a stochastic loading that is realistic in relation to offshore structures, are included in the investigation.A comparison between constant amplitude and variable...

  13. Modern industrial devices of X-ray radioscopy and fluorography for nondestructive testing of welded joints

    International Nuclear Information System (INIS)

    Leonov, B.I.; Sosnin, F.R.; Luk'yanenko, Eh.A.; Veselovskij, L.N.; Kanter, B.M.; Zhdanov, A.V.

    1984-01-01

    Technical data on industrial X-ray television systems with new convertors are given. The convertors are characterized by high sensitivity, defect detectability, lower noise level as compared to earlier produced equipment. Flu uorographic installation for testing welded joints of thick metals is described

  14. Model test study on propagation law of plane stress wave in jointed rock mass under different in-situ stresses

    Science.gov (United States)

    Dong, Qian

    2017-12-01

    The study of propagation law of plane stress wave in jointed rock mass under in-situ stress has important significance for safety excavation of underground rock mass engineering. A model test of the blasting stress waves propagating in the intact rock and jointed rock mass under different in-situ stresses was carried out, and the influencing factors on the propagation law, such as the scale of static loads and the number of joints were studied respectively. The results show that the transmission coefficient of intact rock is larger than that of jointed rock mass under the same loading condition. With the increase of confining pressure, the transmission coefficients of intact rock and jointed rock mass both show an trend of increasing first and then decreasing, and the variation of transmission coefficients in intact rock is smaller than that of jointed rock mass. Transmission coefficient of jointed rock mass decreases with the increase of the number of joints under the same loading condition, when the confining pressure is relatively small, the reduction of transmission coefficients decreases with the increasing of the number of joints, and the variation law of the reduction of transmission coefficients is contrary when the confining pressure is large.

  15. Water flow in single rock joints

    International Nuclear Information System (INIS)

    Hakami, Eva

    1989-05-01

    To study the hydromechanical properties of single rock joints a technique to make transparent replicas of natural joint surfaces has been developed. Five different joint samples were replicated and studied. The aperture distribution of the joints were obtained through a measurement method provided by the transparent replicas. The principle behind the method is that a water drop with a known volume, which is placed inside a joint, will cover a certain area of the surface depending on the average size of aperture at the actual point. Flow tests were performed on the same joint replicas. The tortuousity of the flow and the velocity along single stream lines were measured using colour injections into the water flow through the joints. The equivalent hydraulic apertures determined from the flow tests where shown to be smaller than the average mechanical apertures. The velocity of the flow varies strongly between different paths over the joint depending on the spatial distribution of the apertures. The degree of matedness between the joint surfaces is an important factor influencing the channeling character of the joints. (author) (38 refs.)

  16. Mechanical properties of welded joints of duplex steels

    International Nuclear Information System (INIS)

    Kawiak, M.; Nowacki, J.

    2003-01-01

    The paper presents the study results of mechanical properties of duplex steels UNS S31803 welded joints as well as duplex and NV A36 steels welded joints. They have ben welded by FCAW method in CO 2 using FCW 2205-H flux-cored wire. The joints have been subjected: tensile tests, impact tests, bending tests, hardness tests and metallographic investigations. The influence of welding parameters and mechanical properties of the joints was appreciated. The welding method assured high tensile strength of the joints (approximately 770 MPa) and high impact strength of the welds (approximately 770 J). All samples were broken outside of welds. (author)

  17. Test-retest reliability of joint position and kinesthetic sense in the elbow of healthy subjects

    DEFF Research Database (Denmark)

    Juul-Kristensen, B.; Lund, Hans Aage; Hansen, K.

    2008-01-01

    Proprioception is an important effect measure in neuromuscular function training in physiotherapy. Reliability studies of methods for measuring proprioception are few on joint position sense (JPS) and threshold to detection of a passive movement (TDPM) on the elbow. The aim was to study test-rete...

  18. Achievement reports on joint research of solar energy power generation field test project in fiscal 1997. Part 3 of 3; 1997 nendo taiyoko hatsuden field test jigyo kyodo kenkyu seika hokokusho 3/3

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-08-01

    This report is a collection of 40 achievement reports on joint research of a solar energy power generation field test project. The major contents of the achievement reports relate to the solar energy power generation field test project (summarized as manufacture and installation of solar energy power generation systems, summary of solar energy power generation facilities, status of installation of solar cells, peripheral devices, and daily schedule of the construction). The reports describe achievements of the joint research (names and achievements of the joint research, study presentation, lectures, literatures, status of patents, similar research in and cooperation with other research institutions), generalization of the research, and future problems. Locations of the joint research carried out are hospitals, township hospitals, a science hall for youths, study and educational cities, primary schools, middle schools, high schools, universities, senior health centers, a life cooperative association, retails shops, factories, office buildings, joint governmental office buildings, Shinkansen stations, prefectural industrial testing centers, health and welfare centers, FM broadcasting studios, a town operated hall of technologies, prefectural office buildings and training centers. (NEDO)

  19. Joint maximum-likelihood magnitudes of presumed underground nuclear test explosions

    Science.gov (United States)

    Peacock, Sheila; Douglas, Alan; Bowers, David

    2017-08-01

    Body-wave magnitudes (mb) of 606 seismic disturbances caused by presumed underground nuclear test explosions at specific test sites between 1964 and 1996 have been derived from station amplitudes collected by the International Seismological Centre (ISC), by a joint inversion for mb and station-specific magnitude corrections. A maximum-likelihood method was used to reduce the upward bias of network mean magnitudes caused by data censoring, where arrivals at stations that do not report arrivals are assumed to be hidden by the ambient noise at the time. Threshold noise levels at each station were derived from the ISC amplitudes using the method of Kelly and Lacoss, which fits to the observed magnitude-frequency distribution a Gutenberg-Richter exponential decay truncated at low magnitudes by an error function representing the low-magnitude threshold of the station. The joint maximum-likelihood inversion is applied to arrivals from the sites: Semipalatinsk (Kazakhstan) and Novaya Zemlya, former Soviet Union; Singer (Lop Nor), China; Mururoa and Fangataufa, French Polynesia; and Nevada, USA. At sites where eight or more arrivals could be used to derive magnitudes and station terms for 25 or more explosions (Nevada, Semipalatinsk and Mururoa), the resulting magnitudes and station terms were fixed and a second inversion carried out to derive magnitudes for additional explosions with three or more arrivals. 93 more magnitudes were thus derived. During processing for station thresholds, many stations were rejected for sparsity of data, obvious errors in reported amplitude, or great departure of the reported amplitude-frequency distribution from the expected left-truncated exponential decay. Abrupt changes in monthly mean amplitude at a station apparently coincide with changes in recording equipment and/or analysis method at the station.

  20. The Plastic Deformation of RFSSW Joints During Tensile Tests / Deformacja Plastyczna Wybranych Połączeń RFSSW Podczas Rozciągania

    Directory of Open Access Journals (Sweden)

    Lacki P.

    2015-12-01

    Full Text Available The dynamic development of the friction stir welding (FSW technology is the basis for the design of durabe joints inter alia in the aviation industry. This technology has a prospective application, especially for the aluminum alloys. It is suitable for a broad spectrum of permanent joints. The joints obtained by FSW technology are characterized by good mechanical properties. In this paper, the friction stir spot welding joints were analysed. The example of a structure made using this technology were presented. The lap joints made of 2mm Al 6061-T6 sheets were the investigation subject. The different spot welds arrangements were analysed. The tensile test were performed with optical deformation measurement system, which allow to obtain the plastic deformation field on the sample surface. The plastic strain graphs for the characteristic line passing through the maximum deformation were registered and presented. The experimental results were compared to the FEM numerical analysis. The numerical models were built with 3D-solid elements. The boundary conditions, material properties and geometry of the joints were identical as during experimental investigation. The mechanism of deformation of welded joints during tensile test was described and explained. It has been found that the arrangement of the spot welds with respect to the tensile direction has an important influence on the behaviour and deformation of lap joint.

  1. Single-step brazing process for mono-block joints and mechanical testing

    Energy Technology Data Exchange (ETDEWEB)

    Casalegno, V.; Ferraris, M.; Salvo, M.; Rizzo, S. [Politecnico di Torino, Materials Science and Chemical Engineering Dept., Torino (Italy); Merola, M. [ITER International Team, llER Joint Work Site, Cadarache, 13 - St Paul Lez Durance (France)

    2007-07-01

    Full text of publication follows: Plasma facing components act as actively cooled thermal shields to sustain thermal and particle loads during normal and transient operations in ITER (International Thermonuclear Experimental Reactor). The plasma-facing layer is referred to as 'armour', which is made of either carbon fibre reinforced carbon composite (CFC) or tungsten (W). CFC is the reference design solution for the lower part of the vertical target of the ITER divertor. The armour is joined onto an actively cooled substrate, the heat sink, made of precipitation hardened copper alloy CuCrZr through a thin pure copper interlayer to decrease, by plastic deformation, the joint interface stresses; in fact, the CFC to Cu joint is affected by the CTE mismatch between the ceramic and metallic material. A new method of joining CFC to copper and CFC/Cu to CuCrZr alloy was effectively developed for the flat-type configuration; the feasibility of this process also for mono-block geometry and the development of a procedure for testing mono-block-type mock-ups is described in this work. The mono-block configuration consists of copper alloy pipe shielded by CFC blocks. It is worth noting that in mono-block configuration, the large thermal expansion mismatch between CFC and copper alloy is more significant than for flat-tile configuration, due to curved interfaces. The joining technique foresees a single-step brazing process: the brazing of the three materials (CFC-Cu-CuCrZr) can be performed in a single heat treatment using the same Cu/Ge based braze. The composite surface was modified by solid state reaction with chromium with the purpose of increasing the wettability of CFC by the brazing alloy. The CFC substrate reacts with Cr which, forming a carbide layer, allows a large reduction of the contact angle; then, the brazing of CFC to pure copper and pure copper to CuCrZr by the same treatment is feasible. This process allows to obtain good joints using a non

  2. Single-step brazing process for mono-block joints and mechanical testing

    International Nuclear Information System (INIS)

    Casalegno, V.; Ferraris, M.; Salvo, M.; Rizzo, S.; Merola, M.

    2007-01-01

    Full text of publication follows: Plasma facing components act as actively cooled thermal shields to sustain thermal and particle loads during normal and transient operations in ITER (International Thermonuclear Experimental Reactor). The plasma-facing layer is referred to as 'armour', which is made of either carbon fibre reinforced carbon composite (CFC) or tungsten (W). CFC is the reference design solution for the lower part of the vertical target of the ITER divertor. The armour is joined onto an actively cooled substrate, the heat sink, made of precipitation hardened copper alloy CuCrZr through a thin pure copper interlayer to decrease, by plastic deformation, the joint interface stresses; in fact, the CFC to Cu joint is affected by the CTE mismatch between the ceramic and metallic material. A new method of joining CFC to copper and CFC/Cu to CuCrZr alloy was effectively developed for the flat-type configuration; the feasibility of this process also for mono-block geometry and the development of a procedure for testing mono-block-type mock-ups is described in this work. The mono-block configuration consists of copper alloy pipe shielded by CFC blocks. It is worth noting that in mono-block configuration, the large thermal expansion mismatch between CFC and copper alloy is more significant than for flat-tile configuration, due to curved interfaces. The joining technique foresees a single-step brazing process: the brazing of the three materials (CFC-Cu-CuCrZr) can be performed in a single heat treatment using the same Cu/Ge based braze. The composite surface was modified by solid state reaction with chromium with the purpose of increasing the wettability of CFC by the brazing alloy. The CFC substrate reacts with Cr which, forming a carbide layer, allows a large reduction of the contact angle; then, the brazing of CFC to pure copper and pure copper to CuCrZr by the same treatment is feasible. This process allows to obtain good joints using a non-active brazing

  3. The active straight leg raising test and mobility of the pelvic joints

    OpenAIRE

    Mens, J. M. A.; Vleeming, Andry; Snijders, Chris J.; Stam, Henk J.; Ginai, Abida Z.

    1999-01-01

    Objective signs to assess impairment in patients who are disabled by peripartum pelvic girdle pain hardly exist. The purpose of this study was to develop a clinical test to quantify and qualify disability in these patients. The study examined the relationship between impaired active straight leg raising (ASLR) and mobility of pelvic joints in patients with peripartum pelvic girdle pain, focusing on (1) the reduction of impairment of ASLR when the patient was wearing a pelvic belt, and (2) mot...

  4. Test-retest reliability of tibiofemoral joint space width measurements made using a low-dose standing CT scanner

    Energy Technology Data Exchange (ETDEWEB)

    Segal, Neil A. [University of Kansas Medical Center, Department of Rehabilitation Medicine, 3901 Rainbow Boulevard, Mailstop 1046, Kansas City, KS (United States); The University of Iowa, Iowa City, IA (United States); Bergin, John; Kern, Andrew; Findlay, Christian [The University of Iowa, Iowa City, IA (United States); Anderson, Donald D. [The University of Iowa, Department of Orthopaedics and Rehabilitation, Iowa City, IA (United States)

    2017-02-15

    To determine the test-retest reliability of knee joint space width (JSW) measurements made using standing CT (SCT) imaging. This prospective two-visit study included 50 knees from 30 subjects (66% female; mean ± SD age 58.2 ± 11.3 years; BMI 29.1 ± 5.6 kg/m{sup 2}; 38% KL grade 0-1). Tibiofemoral geometry was obtained from bilateral, approximately 20 fixed-flexed SCT images acquired at visits 2 weeks apart. For each compartment, the total joint area was defined as the area with a JSW <10 mm. The summary measurements of interest were the percentage of the total joint area with a JSW less than 0.5-mm thresholds between 2.0 and 5.0 mm in each tibiofemoral compartment. Test-retest reliability of the summary JSW measurements was assessed by intraclass correlation coefficients (ICC 2,1) for the percentage area engaged at each threshold of JSW and root-mean-square errors (RMSE) were calculated to assess reproducibility. The ICCs were excellent for each threshold assessed, ranging from 0.95 to 0.97 for the lateral and 0.90 to 0.97 for the medial compartment. RMSE ranged from 1.1 to 7.2% for the lateral and from 3.1 to 9.1% for the medial compartment, with better reproducibility at smaller JSW thresholds. The knee joint positioning protocol used demonstrated high day-to-day reliability for SCT 3D tibiofemoral JSW summary measurements repeated 2 weeks apart. Low-dose SCT provides a great deal of information about the joint while maintaining high reliability, making it a suitable alternative to plain radiographs for evaluating JSW in people with knee OA. (orig.)

  5. Test-retest reliability of tibiofemoral joint space width measurements made using a low-dose standing CT scanner

    International Nuclear Information System (INIS)

    Segal, Neil A.; Bergin, John; Kern, Andrew; Findlay, Christian; Anderson, Donald D.

    2017-01-01

    To determine the test-retest reliability of knee joint space width (JSW) measurements made using standing CT (SCT) imaging. This prospective two-visit study included 50 knees from 30 subjects (66% female; mean ± SD age 58.2 ± 11.3 years; BMI 29.1 ± 5.6 kg/m 2 ; 38% KL grade 0-1). Tibiofemoral geometry was obtained from bilateral, approximately 20 fixed-flexed SCT images acquired at visits 2 weeks apart. For each compartment, the total joint area was defined as the area with a JSW <10 mm. The summary measurements of interest were the percentage of the total joint area with a JSW less than 0.5-mm thresholds between 2.0 and 5.0 mm in each tibiofemoral compartment. Test-retest reliability of the summary JSW measurements was assessed by intraclass correlation coefficients (ICC 2,1) for the percentage area engaged at each threshold of JSW and root-mean-square errors (RMSE) were calculated to assess reproducibility. The ICCs were excellent for each threshold assessed, ranging from 0.95 to 0.97 for the lateral and 0.90 to 0.97 for the medial compartment. RMSE ranged from 1.1 to 7.2% for the lateral and from 3.1 to 9.1% for the medial compartment, with better reproducibility at smaller JSW thresholds. The knee joint positioning protocol used demonstrated high day-to-day reliability for SCT 3D tibiofemoral JSW summary measurements repeated 2 weeks apart. Low-dose SCT provides a great deal of information about the joint while maintaining high reliability, making it a suitable alternative to plain radiographs for evaluating JSW in people with knee OA. (orig.)

  6. Testing for identification of locking, maintenance and ratification of large expansion joints; Teste para identificacao de travamento, manutencao e aceitacao de junta de expansao de grande porte

    Energy Technology Data Exchange (ETDEWEB)

    Veiga, Jordana Luiza Barbosa da Costa; Lemos, Ricardo Jose Fernandes; Medeiros, Jorivaldo [Petroleo Brasileiro S.A. (PETROBRAS), Rio de Janeiro, RJ (Brazil)

    2012-07-01

    Piping systems connected to large machines must have high reliability. In particular systems that have traditionally turbo expander large diameter and operate at high temperatures (up to 760 deg C) and low pressure (less than 4 kgf/cm2). This paper focuses on verification, maintenance and ratification of the correct functioning of expansion joints ('JE') of a piping system (72 inches external diameter), connected to a turbo expander system. After verification of 'JE's' locking, it was necessary to intervene in the system to restore the correct operation, for reasons of delivery, only maintenance was carried out in the expansion joints connected to this system. These expansion joints were tested before and after the maintenance to ensure proper operation after installation and verify that the locking system had its origin in 'JE'. This paper presents the degradation observed in JE, maintenance performed and the results of the tests. (author)

  7. Joint diseases

    International Nuclear Information System (INIS)

    Weissman, S.D.

    1989-01-01

    The authors discuss how x-ray examination is essential in the diagnosis and evaluation of the arthritides. Most arthritides are first suspected by the clinician, and x-ray evaluation of these entities along with laboratory testing is important for confirmation of the clinical diagnosis and in staging of the disease process. Several arthritides are often diagnosed first by the podiatrist on x-ray evaluation, including pseudogout, ankylosing spondylitis, early rheumatoid arthritis, degenerative joint disease, and tuberculosis of bone. The joint responds to insult in only a limited number of ways that become apparent on x-ray. The soft tissues surrounding the joint, the articulating bones, and alignment of the joint space may all be involved by the arthritic process. On roentgenographic examination, the soft tissues must be examined for edema, masses, calcifications, and atrophy. The articulating bones must be examined for demineralization, erosions, osteophytes, periosteal reaction, cysts and sclerosis

  8. Achievement reports on joint research of solar energy power generation field test project in fiscal 1997. Part 2 of 3; 1997 nendo taiyoko hatsuden field test jigyo kyodo kenkyu seika hokokusho 2/3

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-08-01

    This report is a collection of 26 achievement reports on joint research of a solar energy power generation field test project. The major contents of the achievement reports relate to the solar energy power generation field test project (summarized as manufacture and installation of solar energy power generation systems, summary of solar energy power generation facilities, peripheral devices, and daily schedule of the construction). The reports describe achievements of the joint research (names and achievements of the joint research, study presentation, lectures, literatures, status of patents, similar research in and cooperation with other research institutions), generalization of the research, and future problems. Locations of the joint research carried out are libraries, kindergartens, health and welfare centers, children's culture centers, general traffic centers, primary and middle schools, river water purifying facilities, credit banks, manufactories, retail shops at car parking areas, office buildings, hospitals, joint prefectural office buildings, municipal health centers, and prefectural general power generation control stations. (NEDO)

  9. Modelling and Experimental Testing of Hybrid Joints Made of: Aluminium Adherends, Adhesive Layers and Rivets for Aerospace Applications

    Directory of Open Access Journals (Sweden)

    Sadowski T.

    2017-09-01

    Full Text Available The contemporary demands in different branches of engineering require application of new multi-component materials and structural systems. Appropriately chosen joining technology can offer significant enhancement of structural system performance in terms of effectiveness, reliability, safety and other design criteria. The modern applications of complex joints are of great technological interest as they permit to combine and to enhance the individual effects of each kind of joint. This is of great importance for modern applications in different branches of engineering: aerospace, mechanical and civil. Therefore in this paper we will focus on the analysis of mechanical response of adhesive joint of aluminium strips reinforced by rivets. The aim of the paper is to investigate experimentally the mechanical behaviour of adhesive joint of aluminium strips reinforced by rivets for industrial applications in aerospace. The considered joint was subjected to uniaxial loading. The tests in this paper were performed for: • classical adhesive joint in order to investigate material parameters for numerical modelling of the hybrid joint • hybrid joining of the structural elements in order to investigate the reinforcement effect. The experiments with application of digital image ARAMIS system allowed for on-line monitoring of the deformation process of the considered joining elements. The particular distributions of displacement fields at the joint surface were estimated for any stage of loading process. Numerical modelling was performed for experimentally investigated specimens. The materials parameters, necessary for calculation, were estimated from experiments. FEA modelling was done with the help of ABAQUS code.

  10. Stochastic joint inversion of hydrogeophysical data for salt tracer test monitoring and hydraulic conductivity imaging

    Science.gov (United States)

    Jardani, A.; Revil, A.; Dupont, J. P.

    2013-02-01

    The assessment of hydraulic conductivity of heterogeneous aquifers is a difficult task using traditional hydrogeological methods (e.g., steady state or transient pumping tests) due to their low spatial resolution. Geophysical measurements performed at the ground surface and in boreholes provide additional information for increasing the resolution and accuracy of the inverted hydraulic conductivity field. We used a stochastic joint inversion of Direct Current (DC) resistivity and self-potential (SP) data plus in situ measurement of the salinity in a downstream well during a synthetic salt tracer experiment to reconstruct the hydraulic conductivity field between two wells. The pilot point parameterization was used to avoid over-parameterization of the inverse problem. Bounds on the model parameters were used to promote a consistent Markov chain Monte Carlo sampling of the model parameters. To evaluate the effectiveness of the joint inversion process, we compared eight cases in which the geophysical data are coupled or not to the in situ sampling of the salinity to map the hydraulic conductivity. We first tested the effectiveness of the inversion of each type of data alone (concentration sampling, self-potential, and DC resistivity), and then we combined the data two by two. We finally combined all the data together to show the value of each type of geophysical data in the joint inversion process because of their different sensitivity map. We also investigated a case in which the data were contaminated with noise and the variogram unknown and inverted stochastically. The results of the inversion revealed that incorporating the self-potential data improves the estimate of hydraulic conductivity field especially when the self-potential data were combined to the salt concentration measurement in the second well or to the time-lapse cross-well electrical resistivity data. Various tests were also performed to quantify the uncertainty in the inverted hydraulic conductivity

  11. A computational model for three-dimensional jointed media with a single joint set

    International Nuclear Information System (INIS)

    Koteras, J.R.

    1994-02-01

    This report describes a three-dimensional model for jointed rock or other media with a single set of joints. The joint set consists of evenly spaced joint planes. The normal joint response is nonlinear elastic and is based on a rational polynomial. Joint shear stress is treated as being linear elastic in the shear stress versus slip displacement before attaining a critical stress level governed by a Mohr-Coulomb faction criterion. The three-dimensional model represents an extension of a two-dimensional, multi-joint model that has been in use for several years. Although most of the concepts in the two-dimensional model translate in a straightforward manner to three dimensions, the concept of slip on the joint planes becomes more complex in three dimensions. While slip in two dimensions can be treated as a scalar quantity, it must be treated as a vector in the joint plane in three dimensions. For the three-dimensional model proposed here, the slip direction is assumed to be the direction of maximum principal strain in the joint plane. Five test problems are presented to verify the correctness of the computational implementation of the model

  12. Thermal and electrical joint test for the helical field coils in the Advanced Toroidal Facility

    International Nuclear Information System (INIS)

    Brown, R.L.; Johnson, R.L.

    1985-01-01

    Initial feasibility studies of a number of configurations for the Advanced Toroidal Facility (ATF) resulted in the selection of a resistive copper continuous-coil torsatron as the optimum device considering the physics program, cost, and schedule. Further conceptual design work was directed toward optimization of this configuration and, if possible, a shorter schedule. It soon became obvious that in order to shorten the schedule, a number of design and fabrication activities should proceed in parallel. This was most critical for the vacuum vessel and the helical field (HF) coils. If the HF coils were wound in place on a completed vacuum vessel, the overall schedule would be significantly (greater than or equal to12 months) longer. The approach of parallel scheduel paths requires that the HF coils be segmented into parts of less than or equal to180 0 of poloidal angle and that joints be made on a turn-by-turn basis when the segments are installed. It was obvious from the outset that the compact and complex geometry of the joint design presented a special challenge in the areas of reliability, assembly, maintenance, disassembly, and cost. Also, electrical, thermal, and force excursions are significant for these joints. A number of soldered, welded, brazed, electroplated, and bolted joints were evaluated. The evaluations examined fabrication feasibility and complexity, thermal-electrical performance at approximately two-thirds of the steady-state design conditions, and installation and assembly processes. Results of the thermal-electrical tests were analyzed and extrapolated to predict performance at peak design parameters. The final selection was a lap-type joint clamped with insulated bolts that pass through the winding packing. 3 refs., 4 figs

  13. Fatigue strength of a single lap joint SPR-bonded

    International Nuclear Information System (INIS)

    Di Franco, G.; Fratini, L.; Pasta, A.

    2011-01-01

    In the last years, hybrid joints, meaning with this the joints which consist in combining a traditional mechanical joint to a layer of adhesive, are gradually attracting the attention of various sectors of the construction of vehicles and transportation industries, for their better performance compared to just mechanical joints (self-piercing riveting SPR, riveting, and so on) or just to bonded joints.The paper investigates the fatigue behavior of a single lap joint self-piercing riveted (SPR) and bonded throughout fatigue tests. The considered geometric configuration allowed the use of two rivets placed longitudinally; an epoxy resin was used as adhesive. In the first part of the work static characterization of the joints was carried out through tensile tests. Then fatigue tests were made with the application of different levels of load. The fatigue curves were also obtained at the varying the distance between the two rivets in order to better assess the joint strength for a given length of overlap.

  14. Achievement reports on joint research of solar energy power generation field test project in fiscal 1997. Part 1 of 3; 1997 nendo taiyoko hatsuden field test jigyo kyodo kenkyu seika hokokusho 1/3

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-08-01

    This report is a collection of 101 achievement reports on joint research of solar energy power generation field test project. The contents of the achievement reports are the results and generalization of the joint research with respect to the solar energy power generation field test project. As regards the locations of executing the joint research, the locations by areas and applications are stated. By areas, the joint research was carried out on gymnasiums, parks, recreation centers in the standard areas, universities, sports facilities, public halls, agricultural associations, aged persons' homes, primary, middle and high schools, prefectural office buildings and industrial technology centers in cold districts; prefectural office buildings, agricultural associations, universities, museums, industrial technology centers in good insolation districts; museums, primary, middle and high schools, parks in strong wind and salt polluted districts; and universities and police stations in snowy districts. By applications, the joint research was performed on life cooperative halls, factories, nursery schools, hospitals, clinics, local newspaper companies, indoor warm-water swimming pools, and mushroom fields. (NEDO)

  15. Achievement reports on joint research of solar energy power generation field test project in fiscal 1997. Part 1 of 3; 1997 nendo taiyoko hatsuden field test jigyo kyodo kenkyu seika hokokusho 1/3

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-08-01

    This report is a collection of 101 achievement reports on joint research of solar energy power generation field test project. The contents of the achievement reports are the results and generalization of the joint research with respect to the solar energy power generation field test project. As regards the locations of executing the joint research, the locations by areas and applications are stated. By areas, the joint research was carried out on gymnasiums, parks, recreation centers in the standard areas, universities, sports facilities, public halls, agricultural associations, aged persons' homes, primary, middle and high schools, prefectural office buildings and industrial technology centers in cold districts; prefectural office buildings, agricultural associations, universities, museums, industrial technology centers in good insolation districts; museums, primary, middle and high schools, parks in strong wind and salt polluted districts; and universities and police stations in snowy districts. By applications, the joint research was performed on life cooperative halls, factories, nursery schools, hospitals, clinics, local newspaper companies, indoor warm-water swimming pools, and mushroom fields. (NEDO)

  16. The diagnostic value of three sacroiliac joint pain provocation tests for sacroiliitis identified by magnetic resonance imaging

    DEFF Research Database (Denmark)

    Arnbak, B; Jurik, A G; Jensen, R K

    2017-01-01

    OBJECTIVES: The aim of the current study was to investigate the diagnostic value of three sacroiliac (SI) joint pain provocation tests for sacroiliitis identified by magnetic resonance imaging (MRI) and stratified by gender. METHOD: Patients without clinical signs of nerve root compression were...

  17. Design and Testing of Low Cost Chair with Round Mortise and Tenon Joints

    Directory of Open Access Journals (Sweden)

    Jaroslav Začal

    2016-01-01

    Full Text Available The present paper focuses on construction of school seats for developing countries from locally available resources using the local industry and low-end technology. Aim of the work is experimental assessment of mechanical properties of joints flexion in angular plane. Furthermore work considers assessment of joint firmness and comparison between various joint types. Paper encloses the review of various joint manufacturing designs (tenon and mortise, which were proposed for its suitable mechanical properties and simplicity of manufacturing. Designated joint type is easiest form of joint construction and technologically feasible for chair manufacturing. The joints were constructed from fir wood. Further the work introduces design of simple seat construction made from massive wood material manufactured by low-end technology with regards to achieving the due specifications. The task of this work is to design the viable manufacturing process of seats and chairs from raw wood and scrap material. Essential part of work is also manufacturing of seat prototype and simplified model of proposed mortise and tenon drill.

  18. Transverse morphology of the sacroiliac joint: effect of angulation and implications for fluoroscopically guided sacroiliac joint injection

    International Nuclear Information System (INIS)

    Ling, B.C.; Lee, J.W.; Man, H.S.J.; Grace, M.G.A.; Lambert, R.G.W.; Jhangri, G.S.

    2006-01-01

    Effects of angulation of computed tomography (CT) reconstruction plane on sacroiliac (SI) joint morphology were studied, and factors influencing the approach to fluoroscopically guided SI joint injection were assessed. CT scans of pelvises were reformatted on 41 subjects, aged 51.7 (±15.1) years. Transverse images were reconstructed at the caudal 3 cm of the SI joint tilting plane of reconstruction from -30 to +30 at 15 increments. Anteroposterior diameter of joint (depth), angle from sagittal plane (orientation angle), and distance from skin were measured. Joint contour was classified, and presence of bone blocking access to the joint was recorded. Comparison between angles were analysed by t-test. Relationships between variables were assessed by a Pearson correlation test. Depth was shorter with angulation in the inferior direction (P<0.01). Orientation angle increased with superior angulation (P<0.01). Distance from skin increased (P<0.01) with angulation in either direction. Joint contour was significantly different from baseline at each angle (P<0.001) but highly variable. Inferior angulation resulted in interposition of ilium between skin and SI joint, and superior angulation caused bone block due to the lower sacrum. None of these features was identified without tilting of the reconstruction plane, and effects were more pronounced with steeper angulation

  19. Transverse morphology of the sacroiliac joint: effect of angulation and implications for fluoroscopically guided sacroiliac joint injection

    Energy Technology Data Exchange (ETDEWEB)

    Ling, B.C.; Lee, J.W.; Man, H.S.J.; Grace, M.G.A.; Lambert, R.G.W. [Department of Radiology and Diagnostic Imaging, University of Alberta Hospital, Edmonton (Canada); Jhangri, G.S. [Department of Public Health Sciences, University of Alberta Hospital, Edmonton (Canada)

    2006-11-15

    Effects of angulation of computed tomography (CT) reconstruction plane on sacroiliac (SI) joint morphology were studied, and factors influencing the approach to fluoroscopically guided SI joint injection were assessed. CT scans of pelvises were reformatted on 41 subjects, aged 51.7 ({+-}15.1) years. Transverse images were reconstructed at the caudal 3 cm of the SI joint tilting plane of reconstruction from -30 to +30 at 15 increments. Anteroposterior diameter of joint (depth), angle from sagittal plane (orientation angle), and distance from skin were measured. Joint contour was classified, and presence of bone blocking access to the joint was recorded. Comparison between angles were analysed by t-test. Relationships between variables were assessed by a Pearson correlation test. Depth was shorter with angulation in the inferior direction (P<0.01). Orientation angle increased with superior angulation (P<0.01). Distance from skin increased (P<0.01) with angulation in either direction. Joint contour was significantly different from baseline at each angle (P<0.001) but highly variable. Inferior angulation resulted in interposition of ilium between skin and SI joint, and superior angulation caused bone block due to the lower sacrum. None of these features was identified without tilting of the reconstruction plane, and effects were more pronounced with steeper angulation.

  20. Design and Testing of Low Cost Chair with Round Mortise and Tenon Joints

    OpenAIRE

    Jaroslav Začal; Petr Dostál; Michal Šustr; Ioannis A. Barboutis

    2016-01-01

    The present paper focuses on construction of school seats for developing countries from locally available resources using the local industry and low-end technology. Aim of the work is experimental assessment of mechanical properties of joints flexion in angular plane. Furthermore work considers assessment of joint firmness and comparison between various joint types. Paper encloses the review of various joint manufacturing designs (tenon and mortise), which were proposed for its suitable mecha...

  1. Association between composites of selected motion palpation and pain provocation tests for sacroiliac joint disorders.

    Science.gov (United States)

    Soleimanifar, Manijeh; Karimi, Noureddin; Arab, Amir Massoud

    2017-04-01

    The sacroiliac joint (SIJ) has been implicated as a potential source of low back and buttock pain. Several types of motion palpation and pain provocation tests are used to evaluate SIJ dysfunction. The purpose of this study was to investigate the relationship between motion palpation and pain provocation tests in assessment of SIJ problems. This study is Descriptive Correlation. 50 patients between the ages of 20 and 65 participated. Four motion palpation tests (Sitting flexion, Standing flexion, Prone knee flexion, Gillet test) and three pain provocation tests (FABER, Posterior shear, Resisted abduction test) were examined. Chi-square analysis was used to assess the relationship between results of the individuals and composites of these two groups of tests. No significant relationship was found between these two groups of tests. It seems that motion palpation tests assess SIJ dysfunction and provocative tests assessed SIJ pain which do not appear to be related. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Effect of Boundary Condition on the Shear Behaviour of Rock Joints in the Direct Shear Test

    Science.gov (United States)

    Bahaaddini, M.

    2017-05-01

    The common method for determination of the mechanical properties of the rock joints is the direct shear test. This paper aims to study the effect of boundary condition on the results of direct shear tests. Experimental studies undertaken in this research showed that the peak shear strength is mostly overestimated. This problem is more pronounced for steep asperities and under high normal stresses. Investigation of the failure mode of these samples showed that tensile cracks are generated at the boundary of sample close to the specimen holders and propagated inside the intact materials. In order to discover the reason of observed failure mechanism in experiments, the direct shear test was simulated using PFC2D. Results of numerical models showed that the gap zone size between the upper and lower specimen holders has a significant effect on the shear mechanism. For the high gap size, stresses concentrate at the vicinity of the tips of specimen holders and result in generation and propagation of tensile cracks inside the intact material. However, by reducing the gap size, stresses are concentrated on asperities, and damage of specimen at its boundary is not observed. Results of this paper show that understanding the shear mechanism of rock joints is an essential step prior to interpreting the results of direct shear tests.

  3. Fabrication of new joints for SST-1 TF coil winding packs

    International Nuclear Information System (INIS)

    Prasad, Upendra; Sharma, A.N.; Patel, Dipak; Doshi, Kalpesh; Khristi, Yohan; Varmora, Pankaj; Chauhan, Pradeep; Jadeja, S.J.; Gupta, Pratibha; Pradhan, S.

    2013-01-01

    Highlights: • We have carried out work related with sub-nanoohm joints for superconducting Tokamak winding packs. • We have established fine tune QA/QC procedures for sub-nanoohm joints fabrication. • We have optimised welding parameters for cable in conduit conductors for fusion relevant magnets. • We have established precised measurement data acquisition system for low resistance measurements at cryogenic temperature. -- Abstract: The Toroidal Field (TF) magnet system of SST-1 has sixteen NbTi/Cu based coils with about one hundred Inter-Pancake (IP) and Inter-Coil (IC) joints. New box type helium leak tight, low DC resistance joints have been designed, fabricated and tested at 5 K temperature and 10 kA DC transport current. The prototype of this joint has been validated in laboratory as well as on spare TF coil winding pack. Moreover, the performance of these joints has been realised and validated on actual sixteen TF winding packs, the joint resistance of ∼0.5 nΩ repeatedly measured on hundreds of IP joints. The quality of terminations and joints was ensured at various stages of fabrication. The quality of joint box material was ensured by visual inspection, chemical analysis, radiography test, ultrasonic test, eddy current test, etc. This paper describes joint design drivers, joint design detail, prototype joint fabrication processes, quality assurance (QA)/quality control (QC) adopted during prototype and actual joint fabrication process, joint resistance measurement on actual TF coils and analysis of measured joint resistance in detail

  4. Neuromuscular knee joint control in adolescents with and without Generalised Joint Hypermobility during landing in the Single leg Hop for Distance test

    DEFF Research Database (Denmark)

    Junge, Tina; Juul-Kristensen, B; Thorlund, J B

    2014-01-01

    Severe knee injuries can occur due to biomechanical factors such as knee joint laxity. Generalised Joint Hypermobility (GJH) has been proposed as an intrinsic risk factor for knee injuries in adults and adolescents, as individuals with GJH often have knee joint hypermobility. Also, critical knee ...

  5. Neuromuscular knee joint control in adolescents with and without Generalised Joint Hypermobility during landing in the Single leg Hop for Distance test

    DEFF Research Database (Denmark)

    Junge, Tina; Juul-Kristensen, B; Thorlund, J B

    Severe knee injuries can occur due to biomechanical factors such as knee joint laxity. Generalised Joint Hypermobility (GJH) has been proposed as an intrinsic risk factor for knee injuries in adults and adolescents, as individuals with GJH often have knee joint hypermobility. Also, critical knee ...

  6. The reliability of knee joint position testing using electrogoniometry

    Directory of Open Access Journals (Sweden)

    Winter Adele

    2008-01-01

    Full Text Available Abstract Background The current investigation examined the inter- and intra-tester reliability of knee joint angle measurements using a flexible Penny and Giles Biometric® electrogoniometer. The clinical utility of electrogoniometry was also addressed. Methods The first study examined the inter- and intra-tester reliability of measurements of knee joint angles in supine, sitting and standing in 35 healthy adults. The second study evaluated inter-tester and intra-tester reliability of knee joint angle measurements in standing and after walking 10 metres in 20 healthy adults, using an enhanced measurement protocol with a more detailed electrogoniometer attachment procedure. Both inter-tester reliability studies involved two testers. Results In the first study, inter-tester reliability (ICC[2,10] ranged from 0.58–0.71 in supine, 0.68–0.79 in sitting and 0.57–0.80 in standing. The standard error of measurement between testers was less than 3.55° and the limits of agreement ranged from -12.51° to 12.21°. Reliability coefficients for intra-tester reliability (ICC[3,10] ranged from 0.75–0.76 in supine, 0.86–0.87 in sitting and 0.87–0.88 in standing. The standard error of measurement for repeated measures by the same tester was less than 1.7° and the limits of agreement ranged from -8.13° to 7.90°. The second study showed that using a more detailed electrogoniometer attachment protocol reduced the error of measurement between testers to 0.5°. Conclusion Using a standardised protocol, reliable measures of knee joint angles can be gained in standing, supine and sitting by using a flexible goniometer.

  7. Transition joints in INDUS-2

    International Nuclear Information System (INIS)

    Sridhar, R.; Amalraj, William; Shukla, S.K.; Jain, A.K.

    2003-01-01

    Full text: A large number of welding joints are being employed in the fabrication of Indus-2 synchrotron storage ring being constructed at CAT. Apart from the TIG welded joints of aluminium alloy vacuum chambers, there are many other joints which are made between dissimilar metals. Stainless steel pipes are friction welded with aluminium pipes and are to be used as pumping ducts between vacuum pumps and the vacuum chambers. Similarly stainless steel flanges are fastened with aluminium flanges through a diamond seal. These joints are tested for a leak tightness of 2 x 10 -10 torr lit/sec of helium. This paper describes the details of the friction welded joints and their application in the Indus-2 synchrotron storage ring

  8. Effect of Strain Rate on Joint Strength and Failure Mode of Lead-Free Solder Joints

    Science.gov (United States)

    Lin, Jian; Lei, Yongping; Fu, Hanguang; Guo, Fu

    2018-03-01

    In surface mount technology, the Sn-3.0Ag-0.5Cu solder joint has a shorter impact lifetime than a traditional lead-tin solder joint. In order to improve the impact property of SnAgCu lead-free solder joints and identify the effect of silver content on tensile strength and impact property, impact experiments were conducted at various strain rates on three selected SnAgCu based solder joints. It was found that joint failure mainly occurred in the solder material with large plastic deformation under low strain rate, while joint failure occurred at the brittle intermetallic compound layer without any plastic deformation at a high strain rate. Joint strength increased with the silver content in SnAgCu alloys in static tensile tests, while the impact property of the solder joint decreased with increasing silver content. When the strain rate was low, plastic deformation occurred with failure and the tensile strength of the Sn-3.0Ag-0.5Cu solder joint was higher than that of Sn-0.3Ag-0.7Cu; when the strain rate was high, joint failure mainly occurred at the brittle interface layer and the Sn-0.3Ag-0.7Cu solder joint had a better impact resistance with a thinner intermetallic compound layer.

  9. Comparative strength analysis and thermal fatigue testing of Be/CuCrZr and Be/GlidCop joints produced by fast brazing

    International Nuclear Information System (INIS)

    Gervash, A.; Mazul, I.; Yablokov, N.; Barabash, V.; Ganenko, A.

    2000-01-01

    Proposing beryllium as plasma facing armour this paper presents the recent results obtained in Russia in the frame of such activities. Last year testing of actively cooled mock-ups produced by fast brazing of Be onto Cu-alloy heat sink allows to consider mentioned Russian method as promising for both PH-copper like CuCrZr and DS-copper like GlidCop. Summarizing recent experimental results with their previous data authors attempt to comparatively investigate a behaviour of Be/CuCrZr and Be/GlidCop joints in ITER relevant conditions. Mechanical properties, brazing zone microstructure and thermal response were taken for comparison. The shear strength for both types of joints was found as 150-200 MPa and did not depend on testing temperature. The brazing zone morphology and microhardness are presented, the thermal fatigue behaviour of investigated joints is described. All main results as well as the nearest future plans are discussed. (orig.)

  10. MR findings of the temporomandibular joint with crepitus

    International Nuclear Information System (INIS)

    Sano, Tsukasa; Yamamoto, Mika; Yamaga, Takayoshi; Takahashi, Koji; Masuda, Saeko; Tagaya, Atsuko; Michi, Ken-ichi; Okano, Tomohiro

    1997-01-01

    Crepitus is an important sign for diagnosis of arthrosis of the temporomandibular joint (TMJ). The presence of crepitus can be evaluated by the listening test previously proposed by our group. However, TMJ can be diagnosed by MR imaging showing the disc position and related findings including bony changes and joint effusion. This study investigated the relationship between the presence of crepitus and pathology of the joint. Fourteen joints with crepitus diagnosed by the listening test were examined in this study. TMJ was categorized into four types based on findings on double spin echo MR images. The results were as follows: Of fourteen joints with crepitus, five (36%) were showed as normal superior disc position. The remaining 9 joints (64%) were diagnosed with disc displacement, of which, 6 showed reduction, one was without reduction and 2 without reduction were associated with arthrosis. Statistical analysis using the data obtained here and other data showed that the joints with crepitus tended to show disk displacement. There was no significant difference between the degree of certainty about the presence of the crepitus and the distribution of joint pathology. Joint effusion was observed only in the joints with displacement. These results indicated that TMJ with crepitus is associated with varied joint pathology. (author)

  11. MR findings of the temporomandibular joint with crepitus

    Energy Technology Data Exchange (ETDEWEB)

    Sano, Tsukasa; Yamamoto, Mika; Yamaga, Takayoshi; Takahashi, Koji; Masuda, Saeko; Tagaya, Atsuko; Michi, Ken-ichi; Okano, Tomohiro [Showa Univ., Tokyo (Japan). School of Dentistry

    1997-06-01

    Crepitus is an important sign for diagnosis of arthrosis of the temporomandibular joint (TMJ). The presence of crepitus can be evaluated by the listening test previously proposed by our group. However, TMJ can be diagnosed by MR imaging showing the disc position and related findings including bony changes and joint effusion. This study investigated the relationship between the presence of crepitus and pathology of the joint. Fourteen joints with crepitus diagnosed by the listening test were examined in this study. TMJ was categorized into four types based on findings on double spin echo MR images. The results were as follows: Of fourteen joints with crepitus, five (36%) were showed as normal superior disc position. The remaining 9 joints (64%) were diagnosed with disc displacement, of which, 6 showed reduction, one was without reduction and 2 without reduction were associated with arthrosis. Statistical analysis using the data obtained here and other data showed that the joints with crepitus tended to show disk displacement. There was no significant difference between the degree of certainty about the presence of the crepitus and the distribution of joint pathology. Joint effusion was observed only in the joints with displacement. These results indicated that TMJ with crepitus is associated with varied joint pathology. (author)

  12. Reliability of agriculture universal joint shafts based on temperature measuring in universal joint bearing assemblies

    Directory of Open Access Journals (Sweden)

    Аleksandar Asonja

    2015-03-01

    Full Text Available This paper presents a research into reliability calculations of agriculture double universal joint shafts based on temperature measuring in cardan-type universal joint bearing assemblies. Special laboratory equipment was developed for this research which is presented in the paper. The objective of this research was to test the real life span of universal joint shafts in the laboratory and in field, to obtain the results which can be used to improve the reliability of universal joint shafts. If the presented research were used along with maintenance measures recommended in the paper and with proper use, the level of reliability of the shafts would be 2.1 times higher. The presented results of the research showed that needle bearings, i.e. bearing assemblies of the joints, are the most critical elements on universal joint shafts and are possible causes of their lower reliability. The second universal joint is the part with the lowest reliability in the observed technical system.

  13. Development of niobium alloy/stainless steel joint by friction welding, (1)

    International Nuclear Information System (INIS)

    Kikuchi, Taiji; Kawamura, Hiroshi.

    1988-08-01

    The niobium alloy and stainless steel have been jointed by the nicrobrazing method generally. However the strength of the jointed part is weaker than that of the mother material. Therefore we developed the niobium alloy(Nb-1 % Zr)/stainless steel(SUS 304) transition joint by the friction welding method. As the tests for the development. We conducted the mechanical tests (tensile test at room temperature, 300 deg C, 500 deg C and 700 deg C, torsion fatigue test and burst test), metallographical observation and electron prove X-ray microanalysis observation. Those tests proved jointed part by the friction welding had enough properties for general uses. (author)

  14. A Note on Testing Mediated Effects in Structural Equation Models: Reconciling Past and Current Research on the Performance of the Test of Joint Significance

    Science.gov (United States)

    Valente, Matthew J.; Gonzalez, Oscar; Miocevic, Milica; MacKinnon, David P.

    2016-01-01

    Methods to assess the significance of mediated effects in education and the social sciences are well studied and fall into two categories: single sample methods and computer-intensive methods. A popular single sample method to detect the significance of the mediated effect is the test of joint significance, and a popular computer-intensive method…

  15. Residual load carrying capacity of timber joints

    NARCIS (Netherlands)

    Kuilen, J.W.G. van de

    1999-01-01

    Timber joints that have been preloaded for 2 to 8 years have been short term tested in accordance with EN 26891. The applied load levels varied between 30% and 50% of the average short term strength. The study comprised nailed, toothed-plate and split-ring joints. All joints were made of spruce and

  16. Is Joint Attention Detectable at a Distance? Three Automated, Internet-Based Tests.

    Science.gov (United States)

    Sheldrake, Rupert; Beeharee, Ashweeni

    2016-01-01

    Joint attention is the shared focus of two or more individuals on the same object. Sensory cues, such as detecting the direction of another person's gaze, play a major role in establishing joint attention. It may also involve a kind of mental resonance that might be felt by the people involved. The aim of this study was to find out whether people could feel when another person was looking at the same picture at the same time, even when the participants were many miles apart. Participants registered online with their names and e-mail addresses, and worked in pairs. After they both logged on for the test they were simultaneously shown one of two photographs, with a 0.5 probability of seeing the same picture. After 20s they were asked if their partner was looking at the same picture or not. After both had registered their guess, the next trial began, with a different pair of pictures. The main outcome measure was the proportion of correct guesses, compared with the 50% mean chance expectation. This test was symmetrical in that all participants were both "senders" and "receivers." In the first experiment, with 11,160 trials, the hit rate was 52.8% (P < 1 × 10(-6)); in the second experiment with 2720 trials, 51.3% (P = .09). The third experiment involved music as well as pictures, and with 8860 trials, the hit rate was 51.9% (P = .0003). Some partners were more than 1000 miles apart, but there were no significant effect of distance. Participants who received immediate feedback about whether their guess was right or wrong did not score significantly better than those without feedback. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Effect of adhesive thickness on adhesively bonded T-joint

    International Nuclear Information System (INIS)

    Abdullah, A R; Afendi, Mohd; Majid, M S Abdul

    2013-01-01

    The aim of this work is to analyze the effect of adhesive thickness on tensile strength of adhesively bonded stainless steel T-joint. Specimens were made from SUS 304 Stainless Steel plate and SUS 304 Stainless Steel perforated plate. Four T-joint specimens with different adhesive thicknesses (0.5, 1.0, 1.5 and 2.0 mm) were made. Experiment result shows T-joint specimen with adhesive thickness of 1.0 mm yield highest maximum load. Identical T-joint specimen jointed by spot welding was also tested. Tensile test shows welded T-Joint had eight times higher tensile load than adhesively bonded T-joint. However, in low pressure application such as urea granulator chamber, high tensile strength is not mandatory. This work is useful for designer in fertilizer industry and others who are searching for alternative to spot welding

  18. Space Suit Joint Torque Measurement Method Validation

    Science.gov (United States)

    Valish, Dana; Eversley, Karina

    2012-01-01

    In 2009 and early 2010, a test method was developed and performed to quantify the torque required to manipulate joints in several existing operational and prototype space suits. This was done in an effort to develop joint torque requirements appropriate for a new Constellation Program space suit system. The same test method was levied on the Constellation space suit contractors to verify that their suit design met the requirements. However, because the original test was set up and conducted by a single test operator there was some question as to whether this method was repeatable enough to be considered a standard verification method for Constellation or other future development programs. In order to validate the method itself, a representative subset of the previous test was repeated, using the same information that would be available to space suit contractors, but set up and conducted by someone not familiar with the previous test. The resultant data was compared using graphical and statistical analysis; the results indicated a significant variance in values reported for a subset of the re-tested joints. Potential variables that could have affected the data were identified and a third round of testing was conducted in an attempt to eliminate and/or quantify the effects of these variables. The results of the third test effort will be used to determine whether or not the proposed joint torque methodology can be applied to future space suit development contracts.

  19. Minimally invasive arthrodesis for chronic sacroiliac joint dysfunction using the SImmetry SI Joint Fusion system.

    Science.gov (United States)

    Miller, Larry E; Block, Jon E

    2014-01-01

    Chronic sacroiliac (SI) joint-related low back pain (LBP) is a common, yet under-diagnosed and undertreated condition due to difficulties in accurate diagnosis and highly variable treatment practices. In patients with debilitating SI-related LBP for at least 6 months duration who have failed conservative management, arthrodesis is a viable option. The SImmetry(®) SI Joint Fusion System is a novel therapy for SI joint fusion, not just fixation, which utilizes a minimally invasive surgical approach, instrumented fixation for immediate stability, and joint preparation with bone grafting for a secure construct in the long term. The purpose of this report is to describe the minimally invasive SI Joint Fusion System, including patient selection criteria, implant characteristics, surgical technique, postoperative recovery, and biomechanical testing results. Advantages and limitations of this system will be discussed.

  20. Rapid Analyses of Polyetheretherketone Wear Characteristics by Accelerated Wear Testing with Microfabricated Surfaces for Artificial Joint Systems.

    Science.gov (United States)

    Su, Chen-Ying; Kuo, Chien-Wei; Fang, Hsu-Wei

    2017-01-01

    Wear particle-induced biological responses are the major factors resulting in the loosening and then failure of total joint arthroplasties. It is feasible to improve the lubrication and reduce the wear of artificial joint system. Polyetheretherketone (PEEK) is considered as a potential bearing material due to its mechanical characteristics of resistance to fatigue strain. The PEEK wear particles have been indicated to be involved in biological responses in vitro, and further studies regarding the wear phenomena and wear particle generation are needed. In this study, we have established an accelerated wear testing system with microfabricated surfaces. Various contact pressures and lubricants have been utilized in the accelerated wear tests. Our results showed that increasing contact pressure resulted in an increase of wear particle sizes and wear rate, and the size of PEEK wear particles can be controlled by the feature size of microfabricated surfaces. These results provided the information rapidly about factors that affect the morphology and amount of PEEK wear particles and can be applied in the future for application of PEEK on the biological articulation system.

  1. Techniques for assessing knee joint pain in arthritis

    Directory of Open Access Journals (Sweden)

    Fu Yu

    2007-03-01

    Full Text Available Abstract The assessment of pain is of critical importance for mechanistic studies as well as for the validation of drug targets. This review will focus on knee joint pain associated with arthritis. Different animal models have been developed for the study of knee joint arthritis. Behavioral tests in animal models of knee joint arthritis typically measure knee joint pain rather indirectly. In recent years, however, progress has been made in the development of tests that actually evaluate the sensitivity of the knee joint in arthritis models. They include measurements of the knee extension angle struggle threshold, hind limb withdrawal reflex threshold of knee compression force, and vocalizations in response to stimulation of the knee. A discussion of pain assessment in humans with arthritis pain conditions concludes this review.

  2. Inter-tester reproducibility and inter-method agreement of two variations of the Beighton test for determining Generalised Joint Hypermobility in primary school children

    DEFF Research Database (Denmark)

    Junge, Tina; Jespersen, Eva; Wedderkopp, Niels

    2013-01-01

    The assessment of Generalised Joint Hypermobility (GJH) is usually based on the Beighton tests, which consist of a series of nine tests. Possible methodological shortcomings can arise, as the tests do not include detailed descriptions of performance, interpretation nor classification of GJH. The ...

  3. Conarticular congruence of the hominoid subtalar joint complex with implications for joint function in Plio-Pleistocene hominins.

    Science.gov (United States)

    Prang, Thomas C

    2016-07-01

    The purpose of this study is to test the hypothesis that conarticular surfaces areas and curvatures are correlates of mobility at the hominoid talocalcaneal and talonavicular joints. Articular surface areas and curvatures of the talonavicular, anterior talocalcaneal, and posterior talocalcaneal joints were quantified using a total of 425 three-dimensional surface models of extant hominoid and fossil hominin tali, calcanei, and naviculars. Quadric surface fitting was used to calculate curvatures, pairwise comparisons were used to evaluate statistical differences between taxa, and regression was used to test for the effects of allometry. Pairwise comparisons show that the distributions of values for joint curvature indices follow the predicted arboreal-terrestrial morphocline in hominoid primates with no effect of body mass (PGLS p > 0.05). OH 8 (Homo habilis) and LB 1 (Homo floresiensis) can be accommodated within the range of human variation for the talonavicular joint, whereas MH2 (Australopithecus sediba) falls within the ranges of variation for Pan troglodytes and Gorilla gorilla in measures of posterior talocalcaneal joint congruity. Joint curvature indices are better discriminators than joint surface area indices, which may reflect a greater contribution of rotation, rather than translation, to joint movement in plantigrade taxa due to discrepancies in conarticular congruence and the "convex-concave" rule. The pattern of joint congruence in Au. sediba contributes to other data on the foot and ankle suggesting that the lateral side of the foot was more mobile than the medial side, which is consistent with suggestions of increased medial weight transfer associated with hyperpronation. Am J Phys Anthropol 160:446-457, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  4. Inter-rater reliability of diagnostic criteria for sacroiliac joint-, disc- and facet joint pain.

    Science.gov (United States)

    van Tilburg, Cornelis W J; Groeneweg, Johannes G; Stronks, Dirk L; Huygen, Frank J P M

    2017-01-01

    Several diagnostic criteria sets are described in the literature to identify low back pain subtypes, but very little is known about the inter-rater reliability of these criteria. We conducted a study to determine the reliability of diagnostic tests that point towards SI joint-, disc- or facet joint pain. Inter-rater reliability study alongside three randomized clinical trials. Multidisciplinary pain center of general hospital. Patients aged 18 or more with medical history and physical examination suggestive of sacroiliac joint-, disc- and facet joint pain on lumbar level. Making use of nowadays most common used diagnostic criteria, a physical examination is taken independently by three physicians (two pain physicians and one orthopedic surgeon). Inter-rater reliability (Kappa (κ) measure of agreement) and significance (p) between raters are presented. Strengths of agreement, indicated with κ values above 0,20, are presented in order of agreement. One hundred patients were included. None of the parameters from the physical investigation had κ values of more than 0.21 (fair) in all pairs of raters. Between two raters (C and D), there was an almost perfect agreement on three parameters, more specifically ``Abnormal sensory and motor examination, hyperactive or diminished reflexes'', ``Sitting exam shows no reflex, motor or sensory signs in the legs'' and ``Straight leg raising (Laségue) negative between 30 and 70 degrees of flexion''. The ``Drop test positive'' parameters had moderate strength of agreement between raters A and D and fair strength between raters A and B. The ``Digital interspinous pressure test positive'' had moderate strength of agreement between raters C and D and fair strength of agreement between raters A and B as well as raters B and C. Three other parameters had a fair strength of agreement between two raters, all other parameters had a slight or poor strength of agreement. Inter-rater reliability, confidence intervals and significance of

  5. Detecting communicative intent in a computerised test of joint attention

    Directory of Open Access Journals (Sweden)

    Nathan Caruana

    2017-01-01

    Full Text Available The successful navigation of social interactions depends on a range of cognitive faculties—including the ability to achieve joint attention with others to share information and experiences. We investigated the influence that intention monitoring processes have on gaze-following response times during joint attention. We employed a virtual reality task in which 16 healthy adults engaged in a collaborative game with a virtual partner to locate a target in a visual array. In the Search task, the virtual partner was programmed to engage in non-communicative gaze shifts in search of the target, establish eye contact, and then display a communicative gaze shift to guide the participant to the target. In the NoSearch task, the virtual partner simply established eye contact and then made a single communicative gaze shift towards the target (i.e., there were no non-communicative gaze shifts in search of the target. Thus, only the Search task required participants to monitor their partner’s communicative intent before responding to joint attention bids. We found that gaze following was significantly slower in the Search task than the NoSearch task. However, the same effect on response times was not observed when participants completed non-social control versions of the Search and NoSearch tasks, in which the avatar’s gaze was replaced by arrow cues. These data demonstrate that the intention monitoring processes involved in differentiating communicative and non-communicative gaze shifts during the Search task had a measurable influence on subsequent joint attention behaviour. The empirical and methodological implications of these findings for the fields of autism and social neuroscience will be discussed.

  6. Thermal fatigue equipment to test joints of materials for high heat flux components

    International Nuclear Information System (INIS)

    Visca, E.; Libera, S.; Orsini, A.; Riccardi, B.; Sacchetti, M.

    2000-01-01

    The activity, carried out in the framework of an ITER divertor task, was aimed at defining a suitable method in order to qualify junctions between armour materials and heat sink of plasma-facing components (PFCs) mock-ups. An equipment able to perform thermal fatigue testing by electrical heating and active water-cooling was constructed and a standard for the sample was defined. In this equipment, during operation cycles, two samples are heated by thermal contact up to a relevant temperature value (350 deg. C) and then the water flow is switched on, thus producing fast cooling with time constants and gradients close to the real operating conditions. The equipment works with a test cycle of about 60 s and is suitable for continuous operation. A complete test consists of about 10000 cycles. After the assembling, the equipment and the control software were optimized to obtain a good reliability. Preliminary tests on mock-ups with flat CFC tiles joined to copper heat sink were performed. Finite-elements calculations were carried out in order to estimate the value of the thermal stresses arising close to the joint under the transient conditions that are characteristic of this equipment

  7. Fuel fabrication processes, design and experimental conditions for the joint US-Swiss mixed carbide test in FFTF (AC-3 test)

    International Nuclear Information System (INIS)

    Stratton, R.W.; Ledergerber, G.; Ingold, F.; Latimer, T.W.; Chidester, K.M.

    1993-01-01

    The preparation of mixed carbide fuel for a joint (US-Swiss) irradiation test in the US Fast Flux Test Facility (FFTF) is described, together with the experiment design and the irradiation conditions. Two fabrication routes were compared. The US produced 66 fuel pins containing pellet fuel via the powder-pellet (dry) route, and the Swiss group produced 25 sphere pac pins of mixed carbide using the internal gelation (wet) route. Both sets of fuel met all t the requirements of the specifications concerning soichiometry, chemical composition and structure. The pin designs were as similar as possible. The test operated successfully in the FFTF for 620 effective full power days until October 1988 and reached over 8% burn up with peak powers of around 80 kW/m. The conclusions were that the choice of sphere pac or pellet fuel for reactor application is dependent on preferred differences in fabrication (e.g. economics and environmental factors) and not on differences in irradiation behaviour. (orig.)

  8. The Ageing Effect of Mechanical Joints on the Tyre/Joint Noises Monitored by a Control Vehicle Method without Traffic Disturbance

    Directory of Open Access Journals (Sweden)

    C. K. Wong

    2013-01-01

    Full Text Available This paper studies the ageing effect of mechanical joints reflecting from the tyre/joint impacting noise by measuring the vehicle structure-borne noise change. Field data is collected applying two measurement methods suitable for newly installed and existing old expansion joints. The measurement methodology is improved by designing and applying a trailer for equipment installation. The main advantage of this method is not to disturb existing traffic by lane closure for measurement. Field measurements were conducted regularly for a study period up to 16 months after new joint replacement to monitor the variation of the structure-borne noise change inside a test vehicle while passing through mechanical joints. Empirical relationship is developed based on the field data of the roadside airborne noise change and the vehicle structure-borne noise change. The roadside tyre/joint noises could be converted using calibrated empirical formula. Key result findings include the following. (1 The vehicle structure-borne noise change is found smallest during the 3rd–6th months even lower than that measured when a new joint is installed. The structure-borne noise change then keeps increasing afterwards till the end of the study period. (2 Similar observations are found in all study cases incorporating various mechanical joint types and test vehicle types.

  9. Testing and evaluation of solidified high-level waste forms. Joint annual progress report 1983

    International Nuclear Information System (INIS)

    Malow, G.

    1985-01-01

    A second joint programme of the European Atomic Community was started in 1981 under the indirect action programme (1980-84), Action No 5 'Testing and evaluation of the properties of various potential materials for immobilizing high activity waste'. The overall objective of the research is to test various European potential solidified high-level radioactive waste forms so as to predict their behaviour after disposal. The most important aspect is to produce data to calculate the activity release from the waste products under the attack of various aqueous solutions. The experiments were partly performed under waste repository relevant conditions and partly under simplified conditions for investigating basic activity release mechanisms. The topics of the programme were: (i) studies of basic leaching mechanisms; (ii) studies of hydrothermal leaching and surface attack of waste glasses; (iii) leach test carried out in contact with granite at low water flow rates; (iv) static leach tests with specimen surrounded by canister and backfill materials; (v) specific isotope leach tests in slowly flowing water; (vi) leach test of actinide spiked samples; (vii) leach tests of highly radioactive samples; (viii) leach tests of alpha radiation stability; (ix) studies of mechanical stability; (x) studies of mineral phases as model compounds and phase relations

  10. Evaluation of taper joints with combined fatigue and crevice corrosion testing: Comparison to human explanted modular prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Reclaru, L., E-mail: lucien.reclaru@pxgroup.com [PX Group S.A., Dep R and D Corrosion and Biocompatibility Group, Bd. des Eplatures 42, CH-2304 La Chaux-de-Fonds (Switzerland); Brooks, R.A. [Orthopaedic Research, Addenbrooke' s Hospital, University of Cambridge, Box 180 Hills Road, CB2 0QQ Cambridge (United Kingdom); Zuberbühler, M. [Smith and Nephew Orthopaedics AG, Schachenalle 29, 5001 Aarau (Switzerland); Eschler, P.-Y.; Constantin, F. [PX Group S.A., Dep R and D Corrosion and Biocompatibility Group, Bd. des Eplatures 42, CH-2304 La Chaux-de-Fonds (Switzerland); Tomoaia, G. [University of Medicine and Pharmacy Iuliu Hateganu of Cluj-Napoca, Dept. of Orthopaedics and Traumatology, Cluj-Napoca (Romania)

    2014-01-01

    The requirement for revision surgery of total joint replacements is increasing and modular joint replacement implants have been developed to provide adjustable prosthetic revision systems with improved intra-operative flexibility. An electrochemical study of the corrosion resistance of the interface between the distal and proximal modules of a modular prosthesis was performed in combination with a cyclic fatigue test. The complexity resides in the existence of interfaces between the distal part, the proximal part, and the dynamometric screw. A new technique for evaluating the resistance to cyclic dynamic corrosion with crevice stimulation was used and the method is presented. In addition, two components of the proximal module of explanted Ti6Al4V and Ti6Al7Nb prostheses were investigated by optical and electron microscopy. Our results reveal that: The electrolyte penetrates into the interface between the distal and proximal modules during cyclic dynamic fatigue tests, the distal module undergoes cracking and corrosion was generated at the interface between the two models; The comparison of the explanted proximal parts with the similar prostheses evaluated following cyclic dynamic crevice corrosion testing showed that there were significant similarities indicating that this method is suitable for evaluating materials used in the fabrication of modular prostheses. - Highlights: • Electrochemical crevice corrosion testing combined with fatigue test conducted on Ti6Al7Nb and Ti6Al4V modular prostheses • Cations released from integral prostheses • Comparison of human explanted modular prostheses with the similar prostheses evaluated in cyclic dynamic crevice corrosion.

  11. Investigation of Miter Corner Joint Strength of Case Furniture from Particleboard

    Directory of Open Access Journals (Sweden)

    Valdas NORVYDAS

    2012-12-01

    Full Text Available Most pieces of case furniture (kitchen and bathroom furniture, cabinets, wardrobes, tables and etc. are made of 18 mm thick wood particle boards finished with various coatings. This three-layered constructional material is obtained by bonding wood particles of different fractions with synthetic resins using heating. The exploitation duration and quality of case furniture is determined by the mechanical properties of wood particle boards and the construction of joints of wood-based panels. On a frequent basis, pieces of case furniture with non-dismantable and dismantable construction are joined by using multidowel glued joints and cam connecting fittings intended for furniture, respectively. Wood-based panels can be joined with mitre joints whose mechanical properties have not undergone testing and comparison with regular joints when applying insertable wooden dowels or furniture connecting fittings. During the testing of particle board properties it was established that joining wood-based panels in this way ensures most efficient use of mechanical characteristics of the particleboard. In addition to the properties of the mitre joint, the tests also allowed determining the bending strength, tensile strength and bonding strength of the constructional material, and providing an original method for testing board properties, which can be successfully applied to the prediction of properties of the mitre joint. Tests were performed by using a universal tensile testing machine P-0.5. Joints were bonded by applying PVA dispersion. The surface of boards was veneered by using mahogany veneer and urea formaldehyde resin. It was found that mitre joints of wood particle boards can withstand loads that are higher from 2 to 4 times, in comparison to glued doweled joints or joints constructed with cam connecting fittings.DOI: http://dx.doi.org/10.5755/j01.ms.18.4.3095

  12. Critical joints in large composite primary aircraft structures. Volume 1: Technical summary

    Science.gov (United States)

    Bunin, Bruce L.

    1985-01-01

    A program was conducted at Douglas Aircraft Company to develop the technology for critical joints in composite wing structure that meets all the design requirements of a 1990 commercial transport aircraft. In fulfilling this objective, analytical procedures for joint design and analysis were developed during Phase 1 of the program. Tests were conducted at the element level to supply the empirical data required for methods development. Large composite multirow joints were tested to verify the selected design concepts and for correlation with analysis predictions. The Phase 2 program included additional tests to provide joint design and analysis data, and culminated with several technology demonstration tests of a major joint area representative of a commercial transport wing. The technology demonstration program of Phase 2 is discussed. The analysis methodology development, structural test program, and correlation between test results and analytical strength predictions are reviewed.

  13. Creep properties of base metal and welded joint of Hastelloy XR produced for High-Temperature Engineering Test Reactor in simulated primary coolant helium

    International Nuclear Information System (INIS)

    Kurata, Yuji; Tsuji, Hirokazu; Shindo, Masami; Suzuki, Tomio; Tanabe, Tatsuhiko; Mutoh, Isao; Hiraga, Kenjiro

    1999-01-01

    Creep tests of base metal, weld metal and welded joint of Hastelloy XR, which had the same chemical composition as Hastelloy XR produced for an intermediate heat exchanger of the High-Temperature Engineering Test Reactor, were conducted in simulated primary coolant helium. The weld metal and welded joint showed almost equal to or longer rupture time than the base metal of Hastelloy XR at 850 and 900degC, although they gave shorter rupture time at 950degC under low stress and at 1,000degC. The welded joint of Hastelloy XR ruptured at the base metal region at 850 and 900degC. On the other hand, it ruptured at the weld metal region at 950 and 1,000degC. The steady-state creep rate of weld metal of Hastelloy XR was lower than that of base metal at 850, 900 and 950degC. The creep rupture strengths of base metal, weld metal and welded joint of Hastelloy XR obtained in this study were confirmed to be much higher than the design allowable creep-rupture stress (S R ) of the Design Allowable Limits below 950degC. (author)

  14. Solar Alpha Rotary Joint (SARJ) Lubrication Interval Test and Evaluation (LITE). Post-Test Grease Analysis

    Science.gov (United States)

    Golden, Johnny L.; Martinez, James E.; Devivar, Rodrigo V.

    2015-01-01

    The Solar Alpha Rotary Joint (SARJ) is a mechanism of the International Space Station (ISS) that orients the solar power generating arrays toward the sun as the ISS orbits our planet. The orientation with the sun must be maintained to fully charge the ISS batteries and maintain all the other ISS electrical systems operating properly. In 2007, just a few months after full deployment, the starboard SARJ developed anomalies that warranted a full investigation including ISS Extravehicular Activity (EVA). The EVA uncovered unexpected debris that was due to degradation of a nitride layer on the SARJ bearing race. ISS personnel identified the failure root-cause and applied an aerospace grease to lubricate the area associated with the anomaly. The corrective action allowed the starboard SARJ to continue operating within the specified engineering parameters. The SARJ LITE (Lubrication Interval Test and Evaluation) program was initiated by NASA, Lockheed Martin, and Boeing to simulate the operation of the ISS SARJ for an extended time. The hardware was designed to test and evaluate the exact material components used aboard the ISS SARJ, but in a controlled area where engineers could continuously monitor the performance. After running the SARJ LITE test for an equivalent of 36+ years of continuous use, the test was opened to evaluate the metallography and lubrication. We have sampled the SARJ LITE rollers and plate to fully assess the grease used for lubrication. Chemical and thermal analysis of these samples has generated information that has allowed us to assess the location, migration, and current condition of the grease. The collective information will be key toward understanding and circumventing any performance deviations involving the ISS SARJ in the years to come.

  15. Effect of rock joint roughness on its cyclic shear behavior

    Directory of Open Access Journals (Sweden)

    S.M. Mahdi Niktabar

    2017-12-01

    Full Text Available Rock joints are often subjected to dynamic loads induced by earthquake and blasting during mining and rock cutting. Hence, cyclic shear load can be induced along the joints and it is important to evaluate the shear behavior of rock joint under this condition. In the present study, synthetic rock joints were prepared with plaster of Paris (PoP. Regular joints were simulated by keeping regular asperity with asperity angles of 15°–15° and 30°–30°, and irregular rock joints which are closer to natural joints were replicated by keeping the asperity angles of 15°–30° and 15°–45°. The sample size and amplitude of roughness were kept the same for both regular and irregular joints which were 298 mm × 298 mm × 125 mm and 5 mm, respectively. Shear test was performed on these joints using a large-scale direct shear testing machine by keeping the frequency and amplitude of shear load under constant cyclic condition with different normal stress values. As expected, the shear strength of rock joints increased with the increases in the asperity angle and normal load during the first cycle of shearing or static load. With the increase of the number of shear cycles, the shear strength decreased for all the asperity angles but the rate of reduction was more in case of high asperity angles. Test results indicated that shear strength of irregular joints was higher than that of regular joints at different cycles of shearing at low normal stress. Shearing and degradation of joint asperities on regular joints were the same between loading and unloading, but different for irregular joints. Shear strength and joint degradation were more significant on the slope of asperity with higher angles on the irregular joint until two angles of asperities became equal during the cycle of shearing and it started behaving like regular joints for subsequent cycles.

  16. Biomechanics of unilateral and bilateral sacroiliac joint stabilization: laboratory investigation.

    Science.gov (United States)

    Lindsey, Derek P; Parrish, Robin; Gundanna, Mukund; Leasure, Jeremi; Yerby, Scott A; Kondrashov, Dimitriy

    2018-03-01

    OBJECTIVE Bilateral symptoms have been reported in 8%-35% of patients with sacroiliac (SI) joint dysfunction. Stabilization of a single SI joint may significantly alter the stresses on the contralateral SI joint. If the contralateral SI joint stresses are significantly increased, degeneration may occur; alternatively, if the stresses are significantly reduced, bilateral stabilization may be unnecessary for patients with bilateral symptoms. The biomechanical effects of 1) unilateral stabilization on the contralateral SI joint and 2) bilateral stabilization on both SI joints are currently unknown. The objectives of this study were to characterize bilateral SI joint range of motion (ROM) and evaluate and compare the biomechanical effects of unilateral and bilateral implant placement for SI joint fusion. METHODS A lumbopelvic model (L5-pelvis) was used to test the ROM of both SI joints in 8 cadavers. A single-leg stance setup was used to load the lumbar spine and measure the ROM of each SI joint in flexion-extension, lateral bending, and axial rotation. Both joints were tested 1) while intact, 2) after unilateral stabilization, and 3) after bilateral stabilization. Stabilization consisted of lateral transiliac placement of 3 triangular titanium plasma-sprayed (TPS) implants. RESULTS Intact testing showed that during single-leg stance the contralateral SI joint had less ROM in flexion-extension (27%), lateral bending (32%), and axial rotation (69%) than the loaded joint. Unilateral stabilization resulted in significant reduction of flexion-extension ROM (46%) on the treated side; no significant ROM changes were observed for the nontreated side. Bilateral stabilization resulted in significant reduction of flexion-extension ROM of the primary (45%) and secondary (75%) SI joints. CONCLUSIONS This study demonstrated that during single-leg loading the ROMs for the stance (loaded) and swing (unloaded) SI joints are significantly different. Unilateral stabilization for SI

  17. Critical joints in large composite aircraft structure

    Science.gov (United States)

    Nelson, W. D.; Bunin, B. L.; Hart-Smith, L. J.

    1983-01-01

    A program was conducted at Douglas Aircraft Company to develop the technology for critical structural joints of composite wing structure that meets design requirements for a 1990 commercial transport aircraft. The prime objective of the program was to demonstrate the ability to reliably predict the strength of large bolted composite joints. Ancillary testing of 180 specimens generated data on strength and load-deflection characteristics which provided input to the joint analysis. Load-sharing between fasteners in multirow bolted joints was computed by the nonlinear analysis program A4EJ. This program was used to predict strengths of 20 additional large subcomponents representing strips from a wing root chordwise splice. In most cases, the predictions were accurate to within a few percent of the test results. In some cases, the observed mode of failure was different than anticipated. The highlight of the subcomponent testing was the consistent ability to achieve gross-section failure strains close to 0.005. That represents a considerable improvement over the state of the art.

  18. Experimental studies of glued Aluminum-glass joints

    Science.gov (United States)

    Ligaj, B.; Wirwicki, M.; Karolewska, K.; Jasińska, A.

    2018-04-01

    Glued steel-glass or aluminum-glass joints are to be found, among other things, in vehicles (cars, buses, trains, trams) as windscreen assembly pieces for the supporting structure. For the purposes of the experiments, samples were made in which the top beam was made of the AW-2017A aluminum alloy and the bottom beam was made of thermally reinforced soda-lime glass whereas the glued joints were made of one-component polyurethane glue Körapur 175. The tests were performed under four-point bending conditions at monotonic incremental bending moment values on the Instron 5965 durability machine. The experimental study of the durability of glued joints under four-point bending conditions with the monotonic incremental bending moment allows to determine the values of stresses, whose value is related to initiation of damage of the tested joint.

  19. Plastic deformation behavior and bonding strength of an EBW joint between 9Cr-ODS and JLF-1 estimated by symmetric four-point bend tests combined with FEM analysis

    International Nuclear Information System (INIS)

    Fu, Haiying; Nagasaka, Takuya; Muroga, Takeo; Guan, Wenhai; Nogami, Shuhei; Serizawa, Hisashi; Geng, Shaofei; Yabuuchi, Kiyohiro; Kimura, Akihiko

    2016-01-01

    The joint between 9Cr-ODS and JLF-1 made by electron beam welding (EBW) fractured at the JLF-1 base metal (BM) during uniaxial tensile tests. Thus, the bonding strength of the joint was not determined and was estimated as more than the ultimate tensile strength of the BM in this case. Symmetric four-point bend tests which concentrate the stress inside the inner span including the weld metal (WM) were carried out at room temperature (RT) and 550 °C to investigate how the bonding strength is more than the ultimate tensile strength of the BM. The normal stress at the center of the weld bead can be calculated with elastic theory up to only 0.25% in strain, though the joint showed more than 10% in strain due to plastic deformation. Thus, finite element method (FEM) was utilized to simulate the plastic deformation behavior of the joint during bend tests. According to the fitting of the FEM output, such as load and displacement of the upper jig contacting the specimens, to the experimental results, the bonding strength of the joint at RT and 550 °C were estimated as 854 MPa and 505 MPa, respectively.

  20. Plastic deformation behavior and bonding strength of an EBW joint between 9Cr-ODS and JLF-1 estimated by symmetric four-point bend tests combined with FEM analysis

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Haiying [SOKENDAI (The Graduate University for Advanced Studies), 322-6 Oroshi-cho, Toki 509-5292 (Japan); Nagasaka, Takuya; Muroga, Takeo [SOKENDAI (The Graduate University for Advanced Studies), 322-6 Oroshi-cho, Toki 509-5292 (Japan); National Institute for Fusion Science, 322-6 Oroshi-cho, Toki 509-5292 (Japan); Guan, Wenhai; Nogami, Shuhei [Tohoku University, 6-6-01-2 Aramaki-aza-Aoba, Aoba-ku, Sendai 980-8578 (Japan); Serizawa, Hisashi [Joining and Welding Research Institute, Osaka University, 11-1 Mihogaoka, Ibaraki 567-0047 (Japan); Geng, Shaofei [SOKENDAI (The Graduate University for Advanced Studies), 322-6 Oroshi-cho, Toki 509-5292 (Japan); Yabuuchi, Kiyohiro; Kimura, Akihiko [Institute of Advanced Energy, Kyoto University, Uji 611-0011 (Japan)

    2016-01-15

    The joint between 9Cr-ODS and JLF-1 made by electron beam welding (EBW) fractured at the JLF-1 base metal (BM) during uniaxial tensile tests. Thus, the bonding strength of the joint was not determined and was estimated as more than the ultimate tensile strength of the BM in this case. Symmetric four-point bend tests which concentrate the stress inside the inner span including the weld metal (WM) were carried out at room temperature (RT) and 550 °C to investigate how the bonding strength is more than the ultimate tensile strength of the BM. The normal stress at the center of the weld bead can be calculated with elastic theory up to only 0.25% in strain, though the joint showed more than 10% in strain due to plastic deformation. Thus, finite element method (FEM) was utilized to simulate the plastic deformation behavior of the joint during bend tests. According to the fitting of the FEM output, such as load and displacement of the upper jig contacting the specimens, to the experimental results, the bonding strength of the joint at RT and 550 °C were estimated as 854 MPa and 505 MPa, respectively.

  1. Development of ASTM Standard for SiC-SiC Joint Testing Final Scientific/Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Jacobsen, George [General Atomics, San Diego, CA (United States); Back, Christina [General Atomics, San Diego, CA (United States)

    2015-10-30

    As the nuclear industry moves to advanced ceramic based materials for cladding and core structural materials for a variety of advanced reactors, new standards and test methods are required for material development and licensing purposes. For example, General Atomics (GA) is actively developing silicon carbide (SiC) based composite cladding (SiC-SiC) for its Energy Multiplier Module (EM2), a high efficiency gas cooled fast reactor. Through DOE funding via the advanced reactor concept program, GA developed a new test method for the nominal joint strength of an endplug sealed to advanced ceramic tubes, Fig. 1-1, at ambient and elevated temperatures called the endplug pushout (EPPO) test. This test utilizes widely available universal mechanical testers coupled with clam shell heaters, and specimen size is relatively small, making it a viable post irradiation test method. The culmination of this effort was a draft of an ASTM test standard that will be submitted for approval to the ASTM C28 ceramic committee. Once the standard has been vetted by the ceramics test community, an industry wide standard methodology to test joined tubular ceramic components will be available for the entire nuclear materials community.

  2. Creep-fatigue evaluation method for weld joint of Mod.9Cr-1Mo steel Part II: Plate bending test and proposal of a simplified evaluation method

    Energy Technology Data Exchange (ETDEWEB)

    Ando, Masanori, E-mail: ando.masanori@jaea.go.jp; Takaya, Shigeru, E-mail: takaya.shigeru@jaea.go.jp

    2016-12-15

    Highlights: • Creep-fatigue evaluation method for weld joint of Mod.9Cr-1Mo steel is proposed. • A simplified evaluation method is also proposed for the codification. • Both proposed evaluation method was validated by the plate bending test. • For codification, the local stress and strain behavior was analyzed. - Abstract: In the present study, to develop an evaluation procedure and design rules for Mod.9Cr-1Mo steel weld joints, a method for evaluating the creep-fatigue life of Mod.9Cr-1Mo steel weld joints was proposed based on finite element analysis (FEA) and a series of cyclic plate bending tests of longitudinal and horizontal seamed plates. The strain concentration and redistribution behaviors were evaluated and the failure cycles were estimated using FEA by considering the test conditions and metallurgical discontinuities in the weld joints. Inelastic FEA models consisting of the base metal, heat-affected zone and weld metal were employed to estimate the elastic follow-up behavior caused by the metallurgical discontinuities. The elastic follow-up factors determined by comparing the elastic and inelastic FEA results were determined to be less than 1.5. Based on the estimated elastic follow-up factors obtained via inelastic FEA, a simplified technique using elastic FEA was proposed for evaluating the creep-fatigue life in Mod.9Cr-1Mo steel weld joints. The creep-fatigue life obtained using the plate bending test was compared to those estimated from the results of inelastic FEA and by a simplified evaluation method.

  3. Creep-fatigue evaluation method for weld joint of Mod.9Cr-1Mo steel Part II: Plate bending test and proposal of a simplified evaluation method

    International Nuclear Information System (INIS)

    Ando, Masanori; Takaya, Shigeru

    2016-01-01

    Highlights: • Creep-fatigue evaluation method for weld joint of Mod.9Cr-1Mo steel is proposed. • A simplified evaluation method is also proposed for the codification. • Both proposed evaluation method was validated by the plate bending test. • For codification, the local stress and strain behavior was analyzed. - Abstract: In the present study, to develop an evaluation procedure and design rules for Mod.9Cr-1Mo steel weld joints, a method for evaluating the creep-fatigue life of Mod.9Cr-1Mo steel weld joints was proposed based on finite element analysis (FEA) and a series of cyclic plate bending tests of longitudinal and horizontal seamed plates. The strain concentration and redistribution behaviors were evaluated and the failure cycles were estimated using FEA by considering the test conditions and metallurgical discontinuities in the weld joints. Inelastic FEA models consisting of the base metal, heat-affected zone and weld metal were employed to estimate the elastic follow-up behavior caused by the metallurgical discontinuities. The elastic follow-up factors determined by comparing the elastic and inelastic FEA results were determined to be less than 1.5. Based on the estimated elastic follow-up factors obtained via inelastic FEA, a simplified technique using elastic FEA was proposed for evaluating the creep-fatigue life in Mod.9Cr-1Mo steel weld joints. The creep-fatigue life obtained using the plate bending test was compared to those estimated from the results of inelastic FEA and by a simplified evaluation method.

  4. Experimental measurement and modeling analysis on mechanical properties of incudostapedial joint.

    Science.gov (United States)

    Zhang, Xiangming; Gan, Rong Z

    2011-10-01

    The incudostapedial (IS) joint between the incus and stapes is a synovial joint consisting of joint capsule, cartilage, and synovial fluid. The mechanical properties of the IS joint directly affect the middle ear transfer function for sound transmission. However, due to the complexity and small size of the joint, the mechanical properties of the IS joint have not been reported in the literature. In this paper, we report our current study on mechanical properties of human IS joint using both experimental measurement and finite element (FE) modeling analysis. Eight IS joint samples with the incus and stapes attached were harvested from human cadaver temporal bones. Tension, compression, stress relaxation and failure tests were performed on those samples in a micro-material testing system. An analytical approach with the hyperelastic Ogden model and a 3D FE model of the IS joint including the cartilage, joint capsule, and synovial fluid were employed to derive mechanical parameters of the IS joint. The comparison of measurements and modeling results reveals the relationship between the mechanical properties and structure of the IS joint.

  5. Characteristics of welded joints of nuclear reactor interest

    International Nuclear Information System (INIS)

    1978-01-01

    The main propose of this work, was the determination of the optical conditions for obtaining welded joints of stainless steel, the quality control of joints obtained by destructive and non-destructive essays, as well as, the first specific essays of fluence and fatigue of the base metals employed. All tests performed in the base metals are very important from the joint of view that the comparison between results obtained with base metals and welded joints allows a the evaluation of the efficiency of the welded joints. (author) [pt

  6. Interfacial microstructure and mechanical properties of brazed aluminum / stainless steel - joints

    Science.gov (United States)

    Fedorov, V.; Elßner, M.; Uhlig, T.; Wagner, G.

    2017-03-01

    Due to the demand of mass and cost reduction, joints based on dissimilar metals become more and more interesting. Especially there is a high interest for joints between stainless steel and aluminum, often necessary for example for automotive heat exchangers. Brazing offers the possibilities to manufacture several joints in one step at, in comparison to fusion welding, lower temperatures. In the recent work, aluminum / stainless steel - joints are produced by induction brazing using an AlSi10 filler and a non-corrosive flux. The mechanical properties are determined by tensile shear tests as well as fatigue tests at ambient and elevated temperatures. The microstructure of the brazed joints and the fracture surfaces of the tested samples are investigated by SEM.

  7. Mo-based compounds for SiC-SiC joints

    Energy Technology Data Exchange (ETDEWEB)

    Magnani, G.; Beaulardi, L.; Mingazzini, C. [ENEA-Faenza (Italy). New Material Div.; Marmo, E. [Fabbricazioni Nucleari S.p.A., Bosco Mavengo (Italy)

    2002-07-01

    New method to joint silicon carbide-based material was developed. It was based on mixture composed mainly by molybdenum silicides. This mixture was tested as brazing mixture with several types of silicon carbide-based material. Microstructural examination of the joint showed that brazing mixture reacted with substrate to form silicon carbide on the surface, while two different molybdenum silicides were identified inside the joint (MoSi{sub 2} and Mo{sub 4.8}Si{sub 3}C{sub 0.6}). Preliminary oxidation tests performed by means of TGA showed high oxidation resistance of this joint over 1000 C making it very promising for high temperature application like ceramic heat exchanger. (orig.)

  8. Patellofemoral Joint Replacement and Nickel Allergy: An Unusual Presentation

    Directory of Open Access Journals (Sweden)

    Farhan Syed

    2015-01-01

    Full Text Available Metal allergy is an unusual complication of joint replacement that may cause aseptic loosening and necessitate joint revision surgery. We present the case of nickel allergy causing aseptic loosening following patellofemoral joint replacement (PFJR in a 54-year-old male. Joint revision surgery to a nickel-free total knee replacement was performed with good results. Our literature review shows that there is no evidence to guide the management of metal allergy in PFJR. The evidence from studies of total knee replacement is limited to retrospective case series and case reports and gives contradictory recommendations. The optimal management strategy for metal allergy in PFJR is not clear. We recommend allergy testing in patients with history of metal allergy and use of an allergen-free implant in those with positive tests. As there is no gold standard test to establish metal allergy, the choice of test should be guided by availability and recommendation from the local unit of dermatology and allergy testing. We recommend investigation for metal allergy in patients with implant loosening where other causes have been excluded.

  9. Effect of joint design on ballistic performance of quenched and tempered steel welded joints

    International Nuclear Information System (INIS)

    Balakrishnan, M.; Balasubramanian, V.; Madhusudhan Reddy, G.

    2014-01-01

    Highlights: • Traditional usage of austenitic stainless steel filler for armour steel welding shows poor ballistic performance. • Earlier efforts show dubious success on ballistic resistance of armour steel joints. • Comparative evaluation of equal/unequal joint design on ballistic performance. • Effect of joint design covers the main aspects of successful bullet stoppage. - Abstract: A study was carried out to evaluate the effect of joint design on ballistic performance of armour grade quenched and tempered steel welded joints. Equal double Vee and unequal double Vee joint configuration were considered in this study. Targets were fabricated using 4 mm thick tungsten carbide hardfaced middle layer; above and below which austenitic stainless steel layers were deposited on both sides of the hardfaced interlayer in both joint configurations. Shielded metal arc welding process was used to deposit for all layers. The fabricated targets were evaluated for its ballistic performance and the results were compared in terms of depth of penetration on weld metal. From the ballistic test results, it was observed that both the targets successfully stopped the bullet penetration at weld center line. Of the two targets, the target made with unequal double Vee joint configuration offered maximum resistance to the bullet penetration at weld metal location without any bulge at the rear side. The higher volume of austenitic stainless steel front layer and the presence of hardfaced interlayer after some depth of soft austenitic stainless steel front layer is the primary reason for the superior ballistic performance of this joint

  10. Use of expansion joints in power stations

    International Nuclear Information System (INIS)

    Birker; Rommerswinkel.

    1976-01-01

    The paper discusses the mode of action of different systems of expansion joints. Special regard is given to the problems of expansion of pipelines of high rated diameter as employed in today's large power plant turbines. Due to the limited space available, the important role of the spring rate of the bellows for the reaction forces and moments acting on the connection points is pointed out. Apart from this details are given on the fabrication and materials selection of expansion joint bellows, and problems are discussed which arise in connection with the mechanical or hydraulic deformation of bellows with one or more walls. The non-destructive methods now in use for the testing of expansion pipe joints are mentioned along with experiments to test their behaviour under changing loads. The paper concludes on some remarks concerning proper transport, storage and installation of expansion pipe joints. (orig./AK) [de

  11. Fatigue and thermal fatigue of Pb-Sn solder joints

    International Nuclear Information System (INIS)

    Frear, D.; Grivas, D.; McCormack, M.; Tribula, D.; Morris, J.W. Jr.

    1987-01-01

    This paper presents a fundamental investigation of the fatigue and thermal fatigue characteristics, with an emphasis on the microstructural development during fatigue, of Sn-Pb solder joints. Fatigue tests were performed in simple shear on both 60Sn-40Pb and 5Sn-95Pb solder joints. Isothermal fatigue tests show increasing fatigue life of 60Sn-40Pb solder joints with decreasing strain and temperature. In contrast, such behavior was not observed in the isothermal fatigue of 5Sn-95Pb solder joints. Thermal fatigue results on 60Sn-40Pb solder cycled between -55 0 C and 125 0 C show that a coarsened region develops in the center of the joint. Both Pb-rich and Sn-rich phases coarsen, and cracks form within these coarsened regions. The failure mode 60Sn-40Pb solder joints in thermal and isothermal fatigue is similar: cracks form intergranularly through the Sn-rich phase or along Sn/Pb interphase boundaries. Extensive cracking is found throughout the 5Sn-95Pb joint for both thermal and isothermal fatigue. In thermal fatigue the 5Sn-95Pb solder joints failed after fewer cycles than 60Sn-40Pb

  12. Stiffness of the ligaments of the human wrist joint

    NARCIS (Netherlands)

    Savelberg, H.H.C.M.; Kooloos, J.G.M.; Huiskes, H.W.J.; Kauer, J.M.G.

    1992-01-01

    The stiffnesses of the superficial ligaments of 14 human cadaver wrist joints have been determined. In these experiments the tested, fresh-frozen carpal joints are divided into a number of bone-ligament-bone complexes, which are loaded in a tensile testing machine at a rate of 66% of the ligaments'

  13. No stabilizing effect of the elbow joint capsule. A kinematic study

    DEFF Research Database (Denmark)

    Nielsen, K K; Olsen, Bo Sanderhoff

    1999-01-01

    We dissected 7 cadaveric elbow specimens, leaving the collateral ligaments and the joint capsule intact. The anterior and the posterior capsule were sequentially transected, followed by kinematic testings. We found no change in joint laxity after total transection of the capsule.......We dissected 7 cadaveric elbow specimens, leaving the collateral ligaments and the joint capsule intact. The anterior and the posterior capsule were sequentially transected, followed by kinematic testings. We found no change in joint laxity after total transection of the capsule....

  14. Ultrasonic Welding of Thermoplastic Composite Coupons for Mechanical Characterization of Welded Joints through Single Lap Shear Testing.

    Science.gov (United States)

    Villegas, Irene F; Palardy, Genevieve

    2016-02-11

    This paper presents a novel straightforward method for ultrasonic welding of thermoplastic-composite coupons in optimum processing conditions. The ultrasonic welding process described in this paper is based on three main pillars. Firstly, flat energy directors are used for preferential heat generation at the joining interface during the welding process. A flat energy director is a neat thermoplastic resin film that is placed between the parts to be joined prior to the welding process and heats up preferentially owing to its lower compressive stiffness relative to the composite substrates. Consequently, flat energy directors provide a simple solution that does not require molding of resin protrusions on the surfaces of the composite substrates, as opposed to ultrasonic welding of unreinforced plastics. Secondly, the process data provided by the ultrasonic welder is used to rapidly define the optimum welding parameters for any thermoplastic composite material combination. Thirdly, displacement control is used in the welding process to ensure consistent quality of the welded joints. According to this method, thermoplastic-composite flat coupons are individually welded in a single lap configuration. Mechanical testing of the welded coupons allows determining the apparent lap shear strength of the joints, which is one of the properties most commonly used to quantify the strength of thermoplastic composite welded joints.

  15. Cold-pressure-welded joints in large multifilamentary Nb--Ti superconductors

    International Nuclear Information System (INIS)

    Cornish, D.N.; Deis, D.W.; Zbasnik, J.P.

    1977-01-01

    A number of mechanical and electrical measurements were made on joints in typical conductors for the proposed mirror fusion test facility (MFTF) and high field test facility (HFTF). For such measurements, a commercially available cold-pressure-welding machine was used. For joints in the MFTF conductor, which has a large proportion of superconductor, joint strength approached conductor strength. For the HFTF conductor, where the Cu-to-superconductor ratio is 4.33/1, the joint is stronger than the conductor. Electrically, the joints were not superconducting.. While the resistance is higher than might be achieved by other forms of joining, we feel that the cold-weld joint has the advantages of simplicity, speed, reliability, and reproducibility. This makes the method attractive for MFTF, where resistance losses will be small compared with the total 4 K refrigeration requirements

  16. Bidirectional transfer between joint and individual actions in a task of discrete force production.

    Science.gov (United States)

    Masumoto, Junya; Inui, Nobuyuki

    2017-07-01

    The present study examined bidirectional learning transfer between joint and individual actions involving discrete isometric force production with the right index finger. To examine the effects of practice of joint action on performance of the individual action, participants performed a pre-test (individual condition), practice blocks (joint condition), and a post-test (individual condition) (IJI task). To examine the effects of practice of the individual action on performance during the joint action, the participants performed a pre-test (joint condition), practice blocks (individual condition), and a post-test (joint condition) (JIJ task). Whereas one participant made pressing movements with a target peak force of 10% maximum voluntary contraction (MVC) in the individual condition, two participants produced the target force of the sum of 10% MVC produced by each of them in the joint condition. In both the IJI and JIJ tasks, absolute errors and standard deviations of peak force were smaller post-test than pre-test, indicating bidirectional transfer between individual and joint conditions for force accuracy and variability. Although the negative correlation between forces produced by two participants (complementary force production) became stronger with practice blocks in the IJI task, there was no difference between the pre- and post-tests for the negative correlation in the JIJ task. In the JIJ task, the decrease in force accuracy and variability during the individual action did not facilitate complementary force production during the joint action. This indicates that practice performed by two people is essential for complementary force production in joint action.

  17. A preclinical physiological assay to test modulation of knee joint pain in the spinal cord: effects of oxycodone and naproxen.

    Science.gov (United States)

    Miranda, Jason A; Stanley, Phil; Gore, Katrina; Turner, Jamie; Dias, Rebecca; Rees, Huw

    2014-01-01

    Sensory processing in the spinal cord during disease states can reveal mechanisms for novel treatments, yet very little is known about pain processing at this level in the most commonly used animal models of articular pain. Here we report a test of the prediction that two clinically effective compounds, naproxen (an NSAID) and oxycodone (an opiate), are efficacious in reducing the response of spinal dorsal horn neurons to noxious knee joint rotation in the monosodium iodoacetate (MIA) sensitized rat. The overall objective for these experiments was to develop a high quality in vivo electrophysiology assay to confidently test novel compounds for efficacy against pain. Given the recent calls for improved preclinical experimental quality we also developed and implemented an Assay Capability Tool to determine the quality of our assay and ensure the quality of our results. Spinal dorsal horn neurons receiving input from the hind limb knee joint were recorded in anesthetized rats 14 days after they were sensitized with 1 mg of MIA. Intravenous administered oxycodone and naproxen were each tested separately for their effects on phasic, tonic, ongoing and afterdischarge action potential counts in response to innocuous and noxious knee joint rotation. Oxycodone reduced tonic spike counts more than the other measures, doing so by up to 85%. Tonic counts were therefore designated the primary endpoint when testing naproxen which reduced counts by up to 81%. Both reductions occurred at doses consistent with clinically effective doses for osteoarthritis. These results demonstrate that clinically effective doses of standard treatments for osteoarthritis reduce pain processing measured at the level of the spinal cord for two different mechanisms. The Assay Capability Tool helped to guide experimental design leading to a high quality and robust preclinical assay to use in discovering novel treatments for pain.

  18. A small punch test technique for characterizing the elastic modulus and fracture behavior of PMMA bone cement used in total joint replacement.

    Science.gov (United States)

    Giddings, V L; Kurtz, S M; Jewett, C W; Foulds, J R; Edidin, A A

    2001-07-01

    Polymethylmethacrylate (PMMA) bone cement is used in total joint replacements to anchor implants to the underlying bone. Establishing and maintaining the integrity of bone cement is thus of critical importance to the long-term outcome of joint replacement surgery. The goal of the present study was to evaluate the suitability of a novel testing technique, the small punch or miniaturized disk bend test, to characterize the elastic modulus and fracture behavior of PMMA. We investigated the hypothesis that the crack initiation behavior of PMMA during the small punch test was sensitive to the test temperature. Miniature disk-shaped specimens, 0.5 mm thick and 6.4 mm in diameter, were prepared from PMMA and Simplex-P bone cement according to manufacturers' instructions. Testing was conducted at ambient and body temperatures, and the effect of test temperature on the elastic modulus and fracture behavior was statistically evaluated using analysis of variance. For both PMMA materials, the test temperature had a significant effect on elastic modulus and crack initiation behavior. At body temperature, the specimens exhibited "ductile" crack initiation, whereas at room temperature "brittle" crack initiation was observed. The small punch test was found to be a sensitive and repeatable test method for evaluating the mechanical behavior of PMMA. In light of the results of this study, future small punch testing should be conducted at body temperature.

  19. The Alpha-defensin Test for Periprosthetic Joint Infections Is Not Affected by Prior Antibiotic Administration.

    Science.gov (United States)

    Shahi, Alisina; Parvizi, Javad; Kazarian, Gregory S; Higuera, Carlos; Frangiamore, Salvatore; Bingham, Joshua; Beauchamp, Christopher; Valle, Craig Della; Deirmengian, Carl

    2016-07-01

    Previous studies have demonstrated that the administration of antibiotics to patients before performing diagnostic testing for periprosthetic joint infection (PJI) can interfere with the accuracy of test results. Although a single-institution study has suggested that alpha-defensin maintains its concentration and sensitivity even after antibiotic treatment, this has not yet been demonstrated in a larger multiinstitutional study. (1) For the evaluation of PJI, is prior antibiotic administration associated with decreased alpha-defensin levels? (2) When prior antibiotics are given, is alpha-defensin a better screening test for PJI than the traditional tests (erythrocyte sedimentation rate [ESR], C-reactive protein [CRP], fluid white blood cells, fluid polymorphonuclear cells [PMNs], and fluid culture)? This retrospective study included data from 106 hip and knee arthroplasties with Musculoskeletal Infection Society-defined PJI from four centers. Of the 106 patients in this study, 30 (28%) were treated with antibiotics for PJI before diagnostic workup (ABX group), and 76 (72%) were not treated before the diagnostic workup (NO-ABX group). There were no differences in age, sex, joint, culture-negative rate, or bacteriology between groups. The patients in the ABX group had antibiotics initiated by physicians who commenced care before assessment for PJI by the treating surgeon's service. We compared the alpha-defensin levels and sensitivity between the ABX and NO-ABX groups. Additionally, the sensitivity of the alpha-defensin test was compared to that of traditional tests for PJI among patients on antibiotics. The administration of antibiotics before performing the alpha-defensin test for PJI was not associated with a decreased median alpha-defensin level (ABX group, median 4.2 [range, 1.79-12.8 S/CO] versus NO-ABX, median 4.9 [range, 0.5-16.8 S/CO], difference of medians: 0.68 S/CO [95% confidence interval {CI}, -0.98 to 1.26], p = 0.451). Furthermore, the alpha

  20. Protection of welded joints against corrosion degradation

    Directory of Open Access Journals (Sweden)

    Jiří Votava

    2013-01-01

    Full Text Available Welded joints form an integral part of steel constructions. Welded joints are undetachable joints, which are however subjects of corrosion processes. The internal energy increases during the fusion welding especially in the heat affected places around the welded joint, which become initiating spot of corrosion degradation.The aim of the experiment is to put a welded joint produced by the MAG method to a test of corrosion degradation under the conditions of the norm ČSN ISO 9227 (salt-spray test. Organic and inorganic anticorrosion protections were applied on welded beads. First of all, there were prepared welded beads using the method MAG; secondly, metallographical analyses of welded metal, heat affected places and base material were processed. Further, microhardness as well as analysis of chemical composition using the EDS microscope were analysed. Based on a current trend in anticorrosion protections, there were chosen three types of protective coatings. First protective system was a double-layer synthetic system, where the base layer is formed by paint Pragroprimer S2000 and the upper layer by finishing paint Industrol S 2013. Second protective system is a duplex system formed by a combination of a base zinc coating with Zinorex paint. The last protective system was formed by zinc dipping only. Corrosion resistance of the individual tested samples was evaluated based on degradation of protective coating. The corrosion origin as well as the corrosion process were observed, the main criteria was the observation of welded bead.

  1. Distal radioulnar joint injuries

    Directory of Open Access Journals (Sweden)

    Binu P Thomas

    2012-01-01

    Full Text Available Distal radioulnar joint is a trochoid joint relatively new in evolution. Along with proximal radioulnar joint , forearm bones and interosseous membrane, it allows pronosupination and load transmission across the wrist. Injuries around distal radioulnar joint are not uncommon, and are usually associated with distal radius fractures,fractures of the ulnar styloid and with the eponymous Galeazzi or Essex_Lopresti fractures. The injury can be purely involving the soft tissue especially the triangular fibrocartilage or the radioulnar ligaments.The patients usually present with ulnar sided wrist pain, features of instability, or restriction of rotation. Difficulty in carrying loads in the hand is a major constraint for these patients. Thorough clinical examination to localize point of tenderness and appropriate provocative tests help in diagnosis. Radiology and MRI are extremely useful, while arthroscopy is the gold standard for evaluation. The treatment protocols are continuously evolving and range from conservative, arthroscopic to open surgical methods. Isolated dislocation are uncommon. Basal fractures of the ulnar styloid tend to make the joint unstable and may require operative intervention. Chronic instability requires reconstruction of the stabilizing ligaments to avoid onset of arthritis. Prosthetic replacement in arthritis is gaining acceptance in the management of arthritis.

  2. Biomechanical evaluation of native acromioclavicular joint ligaments and two reconstruction techniques in the presence of the sternoclavicular joint: A cadaver study.

    Science.gov (United States)

    Masionis, Povilas; Šatkauskas, Igoris; Mikelevičius, Vytautas; Ryliškis, Sigitas; Bučinskas, Vytautas; Griškevičius, Julius; Martin Oliva, Xavier; Monzó Planella, Mariano; Porvaneckas, Narūnas; Uvarovas, Valentinas

    2017-01-01

    Where is over 100 reconstruction techniques described for acromioclavicular (AC) joint reconstruction. Although, it is not clear whether the presence of the sternoclavicular (SC) joint influences the biomechanical properties of native AC ligaments and reconstruction techniques. The purpose of the present study was to investigate the biomechanical properties of native AC joint ligaments and two reconstruction techniques in cadavers with the SC joint still present. We tested eight fresh-frozen cadaver hemithoraces for superior translation (70 N load) and translation increment after 1000 cycles (loading from 20 to 70 N) in a controlled laboratory study. There were three testing groups created: native ligaments, the single coracoclavicular loop (SCL) technique, and the two coracoclavicular loops (TCL) technique. Superior translation was measured after static loading. Translation increment was calculated as the difference between superior translation after cyclic and static loading. Native AC ligaments showed significantly lower translation than the SCL ( p = 0.023) and TCL ( p = 0.046) groups. The SCL had a significantly lower translation increment than native AC ligaments ( p = 0.028). There was no significant difference between reconstruction techniques in terms of translation ( p = 0.865) and translation increment ( p = 0.113). Native AC joint ligaments had better static properties than both reconstruction techniques and worse dynamic biomechanical properties than the SCL technique. The SCL technique appeared to be more secure than the TCL technique. The presence of the SC joint did not have an observable influence on test results.

  3. Demonstration of movement in the sacroiliac joint using ultrasound

    Science.gov (United States)

    Krupinski, Elizabeth A.; Brooks, William J.; Lund, Pamela J.

    1995-05-01

    The goal of this study was to demonstrate quantitatively, using ultrasound (US) recording techniques, the extent of motion of the sacroiliac joint achieved using manual medicine techniques. Initial judgements of perceived (i.e., felt) SI mobility during manual examination were made on 22 subjects. Baseline no movement ultrasound images (static) were obtained of the left and right SI joints at two levels-- posterior-superior-iliac-spine and inferior (PSIS, INF)--and two projections (AP and LAT). Manual medicine spring testing of the SI joint was then performed while ultrasound recordings (on video) were made. The differences between baseline separation of the SI joint and displacement distance during spring testing were measured by six radiologists who typically read US images. Significant movement of at least one SI joint was demonstrated in 91% of the subjects using ultrasound recordings. The extent of movement appeared to corroborate the experience of manual medicine practitioners.

  4. Application of Bionic Design to FRP T-Joints

    Science.gov (United States)

    Luo, Guang-Min; Kuo, Chia-Hung

    2017-09-01

    We applied the concepts of bionics to enhance the mechanical strength of fiberglass reinforced plastic T-joints. The failure modes of the designed arthrosis-like and gum-like joints were determined using three-point bending tests and numerical simulations and compared with those of normal T-joints bonded using structural adhesives. In the simulation, we used cohesive elements to simulate the adhesive interface of the structural adhesive. The experimental and simulation results show that the arthrosis-like joint can effectively delay the failure progress and enhance the bonding strength of T-joints, thus confirming that an appropriate bionic design can effectively control the bonding properties of structural adhesives.

  5. An analysis of a joint shear model for jointed media with orthogonal joint sets

    International Nuclear Information System (INIS)

    Koteras, J.R.

    1991-10-01

    This report describes a joint shear model used in conjunction with a computational model for jointed media with orthogonal joint sets. The joint shear model allows nonlinear behavior for both joint sets. Because nonlinear behavior is allowed for both joint sets, a great many cases must be considered to fully describe the joint shear behavior of the jointed medium. An extensive set of equations is required to describe the joint shear stress and slip displacements that can occur for all the various cases. This report examines possible methods for simplifying this set of equations so that the model can be implemented efficiently form a computational standpoint. The shear model must be examined carefully to obtain a computationally efficient implementation that does not lead to numerical problems. The application to fractures in rock is discussed. 5 refs., 4 figs

  6. Comparison between sensitivities of quality control methods using ultrasonic waves, radiography and acoustic emission for the thick welded joint testing

    International Nuclear Information System (INIS)

    Asty, Michel; Birac, Claude

    1981-09-01

    The testing of the thick welded joints of the nuclear industry is carried out by radiography and ultrasonics on completion of welding. When a fault is found, its repair requires a sometimes deep cut down to the position of the fault, then filling in of the cut by hand welding with a coated electrode. This very costly operation also involves the risk of causing new defects when building up by hand. Listening to the acoustic emission during the welding has been considered in order to seek the possibility of detecting defects when they appear, or soon after. The industrial use of this method would make an instant repair of the defective areas possible at less cost and with greater reliability. The study presented concerns the comparison between the results of the various non-destructive testing methods: radiography, ultrasonics and acoustic emission, for a thick welded joint in which the defects have been brought about [fr

  7. Minimally invasive arthrodesis for chronic sacroiliac joint dysfunction using the SImmetry SI Joint Fusion system

    Directory of Open Access Journals (Sweden)

    Miller LE

    2014-05-01

    Full Text Available Larry E Miller,1,2 Jon E Block21Miller Scientific Consulting, Inc., Asheville, NC, USA; 2The Jon Block Group, San Francisco, CA, USA Abstract: Chronic sacroiliac (SI joint-related low back pain (LBP is a common, yet under-diagnosed and undertreated condition due to difficulties in accurate diagnosis and highly variable treatment practices. In patients with debilitating SI-related LBP for at least 6 months duration who have failed conservative management, arthrodesis is a viable option. The SImmetry® SI Joint Fusion System is a novel therapy for SI joint fusion, not just fixation, which utilizes a minimally invasive surgical approach, instrumented fixation for immediate stability, and joint preparation with bone grafting for a secure construct in the long term. The purpose of this report is to describe the minimally invasive SI Joint Fusion System, including patient selection criteria, implant characteristics, surgical technique, postoperative recovery, and biomechanical testing results. Advantages and limitations of this system will be discussed. Keywords: arthrodesis, fusion, minimally invasive, sacroiliac, SImmetry

  8. Study of the Peak Shear Strength of a Cement-Filled Hard Rock Joint

    Science.gov (United States)

    She, Cheng-Xue; Sun, Fu-Ting

    2018-03-01

    The peak shear strength of a cement-filled hard rock joint is studied by theoretical analysis and laboratory testing. Based on the concept of the shear resistance angle, by combining the statistical method and fractal theory, three new parameters are proposed to characterize the three-dimensional joint morphology, reflecting the effects of the average roughness, multi-scale asperities and the dispersion degree of the roughness distribution. These factors are independent of the measurement scale, and they reflect the anisotropy of the joint roughness. Compressive shear tests are conducted on cement-filled joints. Because joints without cement can be considered special cement-filled joints in which the filling degree of cement is zero, they are also tested. The cement-filled granite joint fails primarily along the granite-cement interfaces. The filling degree of cement controls the joint failure and affects its mechanical behaviour. With a decrease in the filling degree of cement, the joint cohesion decreases; however, the dilatancy angle and the basic friction angle of the interface increase. As the filling degree approaches zero, the cohesion approaches zero, while the dilatancy angle and the basic friction angle increase to those of the joint without cement. A set of formulas is proposed to evaluate the peak shear strength of the joints with and without cement. The formulas are shown to be reasonable by comparison with the tested peak shear strength, and they reflect the anisotropy of the strength. This research deepens the understanding of cement-filled joints and provides a method to evaluate their peak shear strength.

  9. Evaluation of brazing joint of graphites and molybdenum

    International Nuclear Information System (INIS)

    Ishiyama, Shintarou; Kodaira, Tsuneo; Oku, Tatsuo

    1991-01-01

    Bonding test of six kinds of graphites to molybdenum was performed in the following conditions: Brazing elements was obtained by mixing of titanium nickel and copper in the range of 90∼51w%, 40∼10w%, 31∼0w%, respectively. Nonpressed brazing was performed at maximum temperature 1,000degC in a vacuum. Strength tests of these brazed joints were done in the conditions of at high temperature up to, 1,100degC in a vacuum, after 200 heat cycles from room temperature to about 900degC. Optical observation were performed before and after electron beam tests at 3.0 kW/cm 2 ·0.1 s·5 shots. The following results were derived: (1) The good mixing condition was found for titanium, nickel and copper brazing material at 64, 23 and 13w%, respectively. (2) Bending strengths of the brazed joints at room temperature were found to be proportional to the bending strengths of the graphite. (3) Bending strengths of the brazed joints shows no change until tested temperature reached 900degC in a vacuum. (4) Bending strength of the brazed joints showed no change after 200 heat cycles in the temperature range of room ∼ about 900degC and the electron beam tests. (author)

  10. Strengthening of defected beam–column joints using CFRP

    Directory of Open Access Journals (Sweden)

    Mohamed H. Mahmoud

    2014-01-01

    Full Text Available This paper presents an experimental study for the structural performance of reinforced concrete (RC exterior beam–column joints rehabilitated using carbon-fiber-reinforced polymer (CFRP. The present experimental program consists of testing 10 half-scale specimens divided into three groups covering three possible defects in addition to an adequately detailed control specimen. The considered defects include the absence of the transverse reinforcement within the joint core, insufficient bond length for the beam main reinforcement and inadequate spliced implanted column on the joint. Three different strengthening schemes were used to rehabilitate the defected beam–column joints including externally bonded CFRP strips and sheets in addition to near surface mounted (NSM CFRP strips. The failure criteria including ultimate capacity, mode of failure, initial stiffness, ductility and the developed ultimate strain in the reinforcing steel and CFRP were considered and compared for each group for the control and the CFRP-strengthened specimens. The test results showed that the proposed CFRP strengthening configurations represented the best choice for strengthening the first two defects from the viewpoint of the studied failure criteria. On the other hand, the results of the third group showed that strengthening the joint using NSM strip technique enabled the specimen to outperform the structural performance of the control specimen while strengthening the joints using externally bonded CFRP strips and sheets failed to restore the strengthened joints capacity.

  11. Strengthening of defected beam-column joints using CFRP.

    Science.gov (United States)

    Mahmoud, Mohamed H; Afefy, Hamdy M; Kassem, Nesreen M; Fawzy, Tarek M

    2014-01-01

    This paper presents an experimental study for the structural performance of reinforced concrete (RC) exterior beam-column joints rehabilitated using carbon-fiber-reinforced polymer (CFRP). The present experimental program consists of testing 10 half-scale specimens divided into three groups covering three possible defects in addition to an adequately detailed control specimen. The considered defects include the absence of the transverse reinforcement within the joint core, insufficient bond length for the beam main reinforcement and inadequate spliced implanted column on the joint. Three different strengthening schemes were used to rehabilitate the defected beam-column joints including externally bonded CFRP strips and sheets in addition to near surface mounted (NSM) CFRP strips. The failure criteria including ultimate capacity, mode of failure, initial stiffness, ductility and the developed ultimate strain in the reinforcing steel and CFRP were considered and compared for each group for the control and the CFRP-strengthened specimens. The test results showed that the proposed CFRP strengthening configurations represented the best choice for strengthening the first two defects from the viewpoint of the studied failure criteria. On the other hand, the results of the third group showed that strengthening the joint using NSM strip technique enabled the specimen to outperform the structural performance of the control specimen while strengthening the joints using externally bonded CFRP strips and sheets failed to restore the strengthened joints capacity.

  12. Increasing the Strength of Adhesively Bonded Joints by Tapering the Adherends

    International Nuclear Information System (INIS)

    GUESS, TOMMY R.; METZINGER, KURT E.

    1999-01-01

    Wind turbine blades are often fabricated with composite materials. These composite blades are frequently attached to a metallic structure with an adhesive bond. For the baseline composite-to-steel joint considered in this study, failure typically occurs when the adhesive debonds from the steel adherend. Previous efforts established that the adhesive peel stresses strongly influence the strength of these joints for both single-cycle and fatigue loading. This study focused on reducing the adhesive peel stresses present in these joints by tapering the steel adherends. Several different tapers were evaluated using finite element analysis before arriving at a final design. To confirm that the selected taper was an improvement to the existing design, the baseline joint and the modified joint were tested in both compression and tension. In these axial tests, the compressive strengths of the joints with tapered adherends were greater than those of the baseline joints for both single-cycle and low-cycle fatigue. In addition, only a minor reduction in tensile strength was observed for the joints with tapered adherends when compared to the baseline joints. Thus, the modification would be expected to enhance the overall performance of this joint

  13. The Validity and Responsiveness of Isometric Lower Body Multi-Joint Tests of Muscular Strength: a Systematic Review.

    Science.gov (United States)

    Drake, David; Kennedy, Rodney; Wallace, Eric

    2017-12-01

    Researchers and practitioners working in sports medicine and science require valid tests to determine the effectiveness of interventions and enhance understanding of mechanisms underpinning adaptation. Such decision making is influenced by the supportive evidence describing the validity of tests within current research. The objective of this study is to review the validity of lower body isometric multi-joint tests ability to assess muscular strength and determine the current level of supporting evidence. Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines were followed in a systematic fashion to search, assess and synthesize existing literature on this topic. Electronic databases such as Web of Science, CINAHL and PubMed were searched up to 18 March 2015. Potential inclusions were screened against eligibility criteria relating to types of test, measurement instrument, properties of validity assessed and population group and were required to be published in English. The Consensus-based Standards for the Selection of health Measurement Instruments (COSMIN) checklist was used to assess methodological quality and measurement property rating of included studies. Studies rated as fair or better in methodological quality were included in the best evidence synthesis. Fifty-nine studies met the eligibility criteria for quality appraisal. The ten studies that rated fair or better in methodological quality were included in the best evidence synthesis. The most frequently investigated lower body isometric multi-joint tests for validity were the isometric mid-thigh pull and isometric squat. The validity of each of these tests was strong in terms of reliability and construct validity. The evidence for responsiveness of tests was found to be moderate for the isometric squat test and unknown for the isometric mid-thigh pull. No tests using the isometric leg press met the criteria for inclusion in the best evidence synthesis. Researchers and

  14. Expose : procedure and results of the joint experiment verification tests

    Science.gov (United States)

    Panitz, C.; Rettberg, P.; Horneck, G.; Rabbow, E.; Baglioni, P.

    The International Space Station will carry the EXPOSE facility accommodated at the universal workplace URM-D located outside the Russian Service Module. The launch will be affected in 2005 and it is planned to stay in space for 1.5 years. The tray like structure will accomodate 2 chemical and 6 biological PI-experiments or experiment systems of the ROSE (Response of Organisms to Space Environment) consortium. EXPOSE will support long-term in situ studies of microbes in artificial meteorites, as well as of microbial communities from special ecological niches, such as endolithic and evaporitic ecosystems. The either vented or sealed experiment pockets will be covered by an optical filter system to control intensity and spectral range of solar UV irradiation. Control of sun exposure will be achieved by the use of individual shutters. To test the compatibility of the different biological systems and their adaptation to the opportunities and constraints of space conditions a profound ground support program has been developed. The procedure and first results of this joint Experiment Verification Tests (EVT) will be presented. The results will be essential for the success of the EXPOSE mission and have been done in parallel with the development and construction of the final hardware design of the facility. The results of the mission will contribute to the understanding of the organic chemistry processes in space, the biological adaptation strategies to extreme conditions, e.g. on early Earth and Mars, and the distribution of life beyond its planet of origin.

  15. Statistical investigation of the crack initiation lives of piping structural welded joint in low cycle fatigue test of 240 degree C

    International Nuclear Information System (INIS)

    Zhao Yongxiang; Gao Qing; Cai Lixun

    1999-01-01

    A statistical investigation into the fitting of four possible fatigue assumed distributions (three parameter Weibull, two parameter Weibull, lognormal and extreme maximum value distributions) for the crack initiation lives of piping structural welded joint in low cycle fatigue test of 240 degree C is performed by linear regression and least squares methods. The results reveal that the three parameters Weibull distribution may give misleading results in fatigue reliability analysis because the shape parameter is often less than 1. This means that the failure rate decreases with fatigue cycling which is contrary to the general understanding of the behaviour of welded joint. Reliability analyses may also affected by the slightly nonconservative evaluations in tail regions of this distribution. The other three distributions are slightly poor in the total fit effects, but they can be safety assumed in reliability analyses due to the non-conservative evaluations in tail regions mostly and the consistency with the fatigue physics of the structural behaviour of welded joint in the range of engineering practice. In addition, the extreme maximum value distribution is in good consists with the general physical understanding of the structural behaviour of welded joint

  16. Efficacy of Dorsoradial Capsulodesis for Trapeziometacarpal Joint Instability: A Cadaver Study.

    Science.gov (United States)

    Chenoweth, Brian A; O'Mahony, Gavin D; Fitzgerald, Casey; Stoner, Julie A; O'Donoghue, Daniel L; Rayan, Ghazi M

    2017-01-01

    To test the biomechanical properties of the dorsoradial capsulodesis procedure. Six cadaveric hands were used. After exposing the trapeziometacarpal (TMC) joint, we placed Kirschner wires in the distal radius and thumb metacarpal. The rotation shear test was then performed to test the joint axial laxity, and angular measurements using Kirschner wires as reference points were documented. The dorsoradial (DR) ligament and capsule were released, followed by the intermetacarpal (IM) ligament; angular measurements were obtained. Finally, the DR capsulodesis procedure was performed, and final measurements were obtained. Comparisons were made among the various stages of ligament integrity to determine the amount of stability provided by DR capsulodesis. All cadavers demonstrated axial laxity with transection of the DR ligament; an increase in stability was obtained after DR capsulodesis. Transection of the capsule and IM ligament caused increased laxity relative to the native joint (median, 24° and 35°, respectively, on rotational testing). After we performed DR capsulodesis, rotational stability improved by a median of 41° compared with DR ligament transection, 49° compared with DR and IM ligament transection, and 18° relative to the native joint. Dorsoradial capsulodesis restores rotational stability for TMC joint after division of the DR and IM ligaments. The stability achieved was statistically significant compared with both an intact native TMC joint and induced laxity of the TMC joint. The DR capsulodesis procedure may improve rotational stability to the TMC joint. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  17. Characterisation of metal–thermoplastic composite hybrid joints by means of a mandrel peel test

    NARCIS (Netherlands)

    Su, Yibo; de Rooij, Matthias B.; Grouve, Wouter Johannes Bernardus; Warnet, Laurent

    2016-01-01

    Fastener free metal–carbon fibre reinforced thermoplastic composite hybrid joints show potential for application in aerospace structures. The strength of the metal–thermoplastic composite interface is crucial for the performance of the entire hybrid joint. Optimisation of the interface requires an

  18. Functionally Graded Adhesives for Composite Joints

    Science.gov (United States)

    Stapleton, Scott E.; Waas, Anthony M.; Arnold, Steven M.

    2012-01-01

    Adhesives with functionally graded material properties are being considered for use in adhesively bonded joints to reduce the peel stress concentrations located near adherend discontinuities. Several practical concerns impede the actual use of such adhesives. These include increased manufacturing complications, alterations to the grading due to adhesive flow during manufacturing, and whether changing the loading conditions significantly impact the effectiveness of the grading. An analytical study is conducted to address these three concerns. An enhanced joint finite element, which uses an analytical formulation to obtain exact shape functions, is used to model the joint. Furthermore, proof of concept testing is conducted to show the potential advantages of functionally graded adhesives. In this study, grading is achieved by strategically placing glass beads within the adhesive layer at different densities along the joint.

  19. Joint and column behaviour of slotted cold-formed steel studs

    DEFF Research Database (Denmark)

    Andreassen, Michael Joachim; Jönsson, Jeppe

    2015-01-01

    the behaviour of the studs and the track joints. The experiments include a joint design with a special web stiffener used in practice. The studs are made of C-profiles and the tracks of U-profiles. Eight different test series are performed. The test series each have different column lengths, thicknesses...

  20. Joint and column behaviour of slotted cold-formed steel studs

    DEFF Research Database (Denmark)

    Andreassen, Michael Joachim; Jönsson, Jeppe

    2015-01-01

    the behaviour of the studs and the track joints. The experiments included a joint design with a special web stiffener used in practice. The studs were C-sections and the tracks were U-sections. Eight different test series were performed. Each test series had different column lengths and thicknesses, both...

  1. Homogeneity and Strength of Mortar Joints in Pearl-Chain Bridges

    DEFF Research Database (Denmark)

    Lund, Mia Schou Møller; Arvidsson, Michael; Hansen, Kurt Kielsgaard

    2015-01-01

    -to-mix mortar products are tested. To the authors’ knowledge, no previous published work has documented the homogeneity and properties of mortar joints of such a height. Hence, the present study documents a practical test procedure where the homogeneity of three mortar joints measuring 20 x 220 x 2400 mm has...

  2. Design and analysis of push pipe joint under internal pressure and temperature loading

    International Nuclear Information System (INIS)

    Abid, M.; Alam, K.

    2005-01-01

    Pipe joints flanged or welded are commonly used in industry for different applications ranging from sewerage to the high pressure and temperature applications. However, with the rapidly changing technological trends, for optimized space such as for heat exchanger applications, pipe joint design needs special consideration, especially for the internal pipe where no flanged/bolted joint due to space constraint can be used. In addition, where joint opening/closing is the requirement for maintenance or other functional purposes, it becomes inevitable to use some special design. In this paper, a push joint proposed is designed, analyzed, optimized and tested for safe stress and operating conditions. An experimental test rig is designed and tests are performed for internal pressure and temperature separately and joint's behaviour is analyzed in detail for any leaks. FEA results are compared and verified with the mathematical results. Based on the experimental observations, the joint is safe as no leaks are observed. (author)

  3. A concise evidence-based physical examination for diagnosis of acromioclavicular joint pathology: a systematic review.

    Science.gov (United States)

    Krill, Michael K; Rosas, Samuel; Kwon, KiHyun; Dakkak, Andrew; Nwachukwu, Benedict U; McCormick, Frank

    2018-02-01

    The clinical examination of the shoulder joint is an undervalued diagnostic tool for evaluating acromioclavicular (AC) joint pathology. Applying evidence-based clinical tests enables providers to make an accurate diagnosis and minimize costly imaging procedures and potential delays in care. The purpose of this study was to create a decision tree analysis enabling simple and accurate diagnosis of AC joint pathology. A systematic review of the Medline, Ovid and Cochrane Review databases was performed to identify level one and two diagnostic studies evaluating clinical tests for AC joint pathology. Individual test characteristics were combined in series and in parallel to improve sensitivities and specificities. A secondary analysis utilized subjective pre-test probabilities to create a clinical decision tree algorithm with post-test probabilities. The optimal special test combination to screen and confirm AC joint pathology combined Paxinos sign and O'Brien's Test, with a specificity of 95.8% when performed in series; whereas, Paxinos sign and Hawkins-Kennedy Test demonstrated a sensitivity of 93.7% when performed in parallel. Paxinos sign and O'Brien's Test demonstrated the greatest positive likelihood ratio (2.71); whereas, Paxinos sign and Hawkins-Kennedy Test reported the lowest negative likelihood ratio (0.35). No combination of special tests performed in series or in parallel creates more than a small impact on post-test probabilities to screen or confirm AC joint pathology. Paxinos sign and O'Brien's Test is the only special test combination that has a small and sometimes important impact when used both in series and in parallel. Physical examination testing is not beneficial for diagnosis of AC joint pathology when pretest probability is unequivocal. In these instances, it is of benefit to proceed with procedural tests to evaluate AC joint pathology. Ultrasound-guided corticosteroid injections are diagnostic and therapeutic. An ultrasound-guided AC joint

  4. Finite element analysis of adanced composite structures containing mechanically fastened joints

    International Nuclear Information System (INIS)

    Baumann, E.

    1982-01-01

    Although the usual engineering practice is to ignore joint effects in finite element models of overall structures, there are times when the inclusion of fastener effects in a model is necessary for accurate analysis. This paper describes some simple but accurate methods for accommodating this modeling requirement. The approach involves correlation of test results from a few composite mechanically fastened joints with finite element analyses of joints. It is assumed that if the fastener actions in the test articles can be properly predicted by simple finite element techniques, then these same techniques can be applied to large overall structure models. During the course of this test-analysis effort it was determined that it is possible to obtain correct results for overall structure-joint analyses by using simple modeling concepts provided special care is employed. Also, some emphasis is given in this paper to the importance of properly reducing test data in order to obtain meaningful correlations with finite element analysis. Finally, for those interested, the appendix contains brief descriptions of the test results and failure modes explored in the test program. (orig.)

  5. Model-Based Estimation of Ankle Joint Stiffness

    Directory of Open Access Journals (Sweden)

    Berno J. E. Misgeld

    2017-03-01

    Full Text Available We address the estimation of biomechanical parameters with wearable measurement technologies. In particular, we focus on the estimation of sagittal plane ankle joint stiffness in dorsiflexion/plantar flexion. For this estimation, a novel nonlinear biomechanical model of the lower leg was formulated that is driven by electromyographic signals. The model incorporates a two-dimensional kinematic description in the sagittal plane for the calculation of muscle lever arms and torques. To reduce estimation errors due to model uncertainties, a filtering algorithm is necessary that employs segmental orientation sensor measurements. Because of the model’s inherent nonlinearities and nonsmooth dynamics, a square-root cubature Kalman filter was developed. The performance of the novel estimation approach was evaluated in silico and in an experimental procedure. The experimental study was conducted with body-worn sensors and a test-bench that was specifically designed to obtain reference angle and torque measurements for a single joint. Results show that the filter is able to reconstruct joint angle positions, velocities and torque, as well as, joint stiffness during experimental test bench movements.

  6. Model-Based Estimation of Ankle Joint Stiffness.

    Science.gov (United States)

    Misgeld, Berno J E; Zhang, Tony; Lüken, Markus J; Leonhardt, Steffen

    2017-03-29

    We address the estimation of biomechanical parameters with wearable measurement technologies. In particular, we focus on the estimation of sagittal plane ankle joint stiffness in dorsiflexion/plantar flexion. For this estimation, a novel nonlinear biomechanical model of the lower leg was formulated that is driven by electromyographic signals. The model incorporates a two-dimensional kinematic description in the sagittal plane for the calculation of muscle lever arms and torques. To reduce estimation errors due to model uncertainties, a filtering algorithm is necessary that employs segmental orientation sensor measurements. Because of the model's inherent nonlinearities and nonsmooth dynamics, a square-root cubature Kalman filter was developed. The performance of the novel estimation approach was evaluated in silico and in an experimental procedure. The experimental study was conducted with body-worn sensors and a test-bench that was specifically designed to obtain reference angle and torque measurements for a single joint. Results show that the filter is able to reconstruct joint angle positions, velocities and torque, as well as, joint stiffness during experimental test bench movements.

  7. Model-Based Estimation of Ankle Joint Stiffness

    Science.gov (United States)

    Misgeld, Berno J. E.; Zhang, Tony; Lüken, Markus J.; Leonhardt, Steffen

    2017-01-01

    We address the estimation of biomechanical parameters with wearable measurement technologies. In particular, we focus on the estimation of sagittal plane ankle joint stiffness in dorsiflexion/plantar flexion. For this estimation, a novel nonlinear biomechanical model of the lower leg was formulated that is driven by electromyographic signals. The model incorporates a two-dimensional kinematic description in the sagittal plane for the calculation of muscle lever arms and torques. To reduce estimation errors due to model uncertainties, a filtering algorithm is necessary that employs segmental orientation sensor measurements. Because of the model’s inherent nonlinearities and nonsmooth dynamics, a square-root cubature Kalman filter was developed. The performance of the novel estimation approach was evaluated in silico and in an experimental procedure. The experimental study was conducted with body-worn sensors and a test-bench that was specifically designed to obtain reference angle and torque measurements for a single joint. Results show that the filter is able to reconstruct joint angle positions, velocities and torque, as well as, joint stiffness during experimental test bench movements. PMID:28353683

  8. In-plane Shear Joint Capacity of Pracast Lightweight Aggregate Concrete Elements

    DEFF Research Database (Denmark)

    Larsen, Henning; Goltermann, Per; Scherfig, Søren

    1996-01-01

    The paper establishes and documents formulas for the in-plane shear capacity between precast elements of lightweight aggregate concrete with open structure. The joints investigated are rough or toothed and have all been precracked prior to the testing in order to obtain realistic test results....... The paper documents the shear force capacity for the joint strength between the most common joint types between precast LAC roof and floor elements used in Scandinavia....

  9. Effects of individual strengthening exercises for the stabilization muscles on the nutation torque of the sacroiliac joint in a sedentary worker with nonspecific sacroiliac joint pain.

    Science.gov (United States)

    Yoo, Won-Gyu

    2015-01-01

    [Purpose] We investigated the effects of individual strengthening exercises for the stabilization muscles on the nutation torque of the sacroiliac joint in a sedentary worker with nonspecific sacroiliac joint pain. [Subject] A 36-year-old female complained of pain in the sacroiliac joints. [Methods] The subject performed individual strengthening exercises for the stabilization muscles for nutation torque of the sacroiliac joint for 3 weeks. Pain-provocation tests and visual analog scale (VAS) scores were evaluated before and after the exercises. [Results] After performing the individual strengthening exercises for the erector spinae, rectus abdominis, and biceps femoris muscles for 3 weeks, the subject displayed no pain in the pain provocation tests, and the VAS score was 2/10. [Conclusion] The individual strengthening exercises for the stabilization muscles of the sacroiliac joint performed in the present study appear to be effective for sedentary workers with sacroiliac joint pain.

  10. Joint hypermobility: incidence and some clinical symptoms

    Directory of Open Access Journals (Sweden)

    M P Isaev

    2003-01-01

    Full Text Available Objective. To study joint mobility range among urban population aged 18 to 30 years and to assess association of joint and other connective tissue structures disorders clinical signs with hypermobility. Material and methods. 769 randomly selected individuals aged 18 to 30 (mean - 25,56 years (419 female and 350 male were examined. Hypermobility was assessed with 9-point Beighton scale. Examination included skin stretchability evaluation at elbow back surface, determination of flat feet, high palate, joint pain and deformities of knee joints, joint luxation and subluxation, hand and feet vasospastic disturbances, cardiac pain, oculist examination. Methods of variational statistics were used (x2, Student's test, Spirmen's correlation. Results. Hypermobility incidence and joint mobility in population aged 18 to 30 years in Orenburg largely comply with data received in Moscow. Joint mobility up to 5 points in women and up to 4 points in men is usual for persons of this age and in absence of additional clinical symptoms cannot be considered as pathological. Knee joint deformities, presence of high palate, cardiac pain accompanied by signs of vegetative dysfunction, hand and feet vasospastic disturbances are significantly connected with degree of joint mobility and in some cases can help in hypermobility syndrome diagnosis.

  11. HIP JOINT AND HIP ENDOPROSTHESIS BIOMECHANICS

    OpenAIRE

    Jakub Gryka

    2017-01-01

    This article contains a description of the basic issues related to anatomy, loading of hip joint and its endoprosthesis research methods. The methods of testing and simulating hip joint loads, factors that influence the selection of parameters during the design of prostheses, typical solutions to engineering problems related to this topic are presented. The article concludes with short summary of the finite element method for the design of hip replacements.

  12. Preliminary Sensorimotor and Cardiovascular Results from the Joint Russian/U.S. Pilot Field Test in Preparation for the Full Field Test

    Science.gov (United States)

    Reschke, M. F.; Kozlovskaya, I. B.; Tomilovskaya, E. S.; Bloomberg, J. J.; Platts, S. H.; Rukavishnikov, I. V.; Fomina, E. V.; Stenger, M. B.; Lee, S. M. C.; Wood, S. J.; hide

    2014-01-01

    Ongoing collaborative research efforts between NASA's Neuroscience and Cardiovascular Laboratories, and the Institute of Biomedical Problems' (IBMP) Sensory-Motor and Countermeasures Laboratories have been measuring functional sensorimotor, cardiovascular and strength responses following bed rest, dry immersion, short-duration (Space Shuttle) and long-duration (Mir and International Space Station [ISS]) space flights. While the unloading paradigms associated with dry immersion and bed rest does serve as acceptable flight analogs, testing of crew responses following the long-duration flights previously has not been possible until a minimum of 24 hours after landing. As a result, it is not possible to estimate the nonlinear trend of the early (testing at the landing site. By joint agreement, this research effort has been identified as the functional Field Test (FT). For practical reasons the FT has been divided into two phases: the full FT and a preliminary pilot version (PFT) of the FT that is reduced in both length and scope. The primary goal of this research is to determine functional abilities in long-duration space-flight crews beginning as soon after landing as possible (test in conjunction with postural ataxia testing (quiet stance sway) as well as cardiovascular responses during the other functional tasks. In addition to the immediate post-landing collection of data for the full FT, postflight data will be acquired between one and three more other times within the 24 hours after landing and will continue over the subsequent weeks until functional sensorimotor and cardiovascular responses have returned to preflight normative values. The PFT represents a single trial run comprised of a jointly agreed upon subset of tests from the full FT and relies heavily on IBMP's Sensory-Motor and Countermeasures Laboratories for content and implementation. The PFT has been collected on several ISS missions. Testing included: (1) a sit-to-stand test, (2) recovery from a fall

  13. Finite element analysis of cylindrical pressure vessels having a misalignment in a circumferential joint

    International Nuclear Information System (INIS)

    Aseer Brabin, T.; Christopher, T.; Nageswara Rao, B.

    2010-01-01

    Finite element analysis (FEA) has been carried out to obtain the elastic stress distribution at cylinder-to-cylinder junction in pressurized shell structures that have applications in space - vehicle design. To validate the finite element modeling and analysis results, three joint configurations, (viz., unfilleted butt joint with equal thickness, unfilleted butt joint with unequal thickness and filleted butt joint with equal thickness) having test results in open literature were considered. The peak stress values for these configurations obtained from FEA are close to that of test results. The peak stress value is found to reduce due to filleted butt joint as expected and also confirmed through test results.

  14. Joints in Tempered Glass Using Glass Dowel Discs

    DEFF Research Database (Denmark)

    Nielsen, Jens Henrik; Poulsen, Peter Noe

    One of the major reasons for using glass in structures is its transparency; however, traditional mechanical joints such as friction joints and steel dowel pinned connections are compromising the transparency. The present paper describes a novel joint which is practically maintaining the complete...... transparency of the glass. This is achieved by using a dowel disc made entirely of tempered glass. The concept of the joint is proved by pilot tests and numerical models. From the work it is seen that the load-carrying capacity of such a connection is similar to what is found for traditionally in-plane loaded...

  15. MR diagnosis of temporomandibular joint. A study of joint effusion

    International Nuclear Information System (INIS)

    Kaneda, Takashi; Yamashiro, Mitsuaki; Ozawa, Kaoru; Suzuki, Hiromi; Okada, Hiroyuki; Yamamoto, Hirotsugu

    1998-01-01

    The purposes of this study were to evaluate the relationship between correlation of MR joint effusion of the temporomandibular joint and disk position, to evaluate the relationship between joint effusion and aging, and to assess the frequency of MR joint effusion of bilateral temporomandibular joints. The temporomandibular joints of 192 patients with clinical symptoms of temporomandibular joint disorders were imaged bilaterally using high field, surface-coil MR imaging. Oblique sagittal and coronal proton density-weighted and T2-weighted images were obtained. Imaging findings of joint effusion were correlated with disk position, aging, and bilateral temporomandibular joints. MR showed effusion in 4% of the joints with normal superior disk position, 36% of the joints with disk displacement with reduction, and 45% of the joints with disk displacement without reduction. There were significant differences in the incidence of joint effusion between normal disk position and anterior disk displacement with or without reduction. Younger patients less than 40 years were significant higher the incidence of joint effusion than those of older patients. A significant association was seen between joint effusion and aging. MR showed effusion in 17% of the unilateral temporomandibular joint, 24% of the bilateral temporomandibular joints. There was no significant difference between unilateral and bilateral case. These results indicated that joint effusion using MR imaging was associated with varied temporomandibular joint pathologic states. (author)

  16. Evaluation of effects of different treatments for the wrist joints of subdominant hands using joint proprioception and writing time.

    Science.gov (United States)

    Hu, Chunying; Huang, Qiuchen; Yu, Lili; Hu, Yue; Rongming, Xia; Li, Zhou; Xiaojiao, Fu; Gu, Rui; Cui, Yao; Ge, Meng; Xu, Yanfeng; Liu, Jianfeng

    2016-05-01

    [Purpose] The purpose of this study was to examine immediate effects of strength training and NJF distal resistance training in wrist joints by using writing time and evaluation of proprioception using the JPE test. [Subjects and Methods] The subjects were 12 young healthy people (24.2 ± 3.1 y, 169.7 ± 6.5 cm, 65.3 ± 12.6 kg). Two isotonic contraction techniques were applied on the wrist joint: wrist joint extension muscle strength training (MST) and the wrist joint extension pattern of NJF. The uppercase English alphabet writing time and joint position errors of the left upper limb were measured before and after one intervention session of MST and NJF. [Results] The decrease in errors in wrist extension angle repetition and the writing time represented the improvement resulting from NJF. [Conclusion] This result suggests that the subdominant hands wrist joint proprioception and writing function can be improved by NJF together with proximal resistance training.

  17. Experimental Studies on the Mechanical Behaviour of Rock Joints with Various Openings

    Science.gov (United States)

    Li, Y.; Oh, J.; Mitra, R.; Hebblewhite, B.

    2016-03-01

    The mechanical behaviour of rough joints is markedly affected by the degree of joint opening. A systematic experimental study was conducted to investigate the effect of the initial opening on both normal and shear deformations of rock joints. Two types of joints with triangular asperities were produced in the laboratory and subjected to compression tests and direct shear tests with different initial opening values. The results showed that opened rock joints allow much greater normal closure and result in much lower normal stiffness. A semi-logarithmic law incorporating the degree of interlocking is proposed to describe the normal deformation of opened rock joints. The proposed equation agrees well with the experimental results. Additionally, the results of direct shear tests demonstrated that shear strength and dilation are reduced because of reduced involvement of and increased damage to asperities in the process of shearing. The results indicate that constitutive models of rock joints that consider the true asperity contact area can be used to predict shear resistance along opened rock joints. Because rock masses are loosened and rock joints become open after excavation, the model suggested in this study can be incorporated into numerical procedures such as finite-element or discrete-element methods. Use of the model could then increase the accuracy and reliability of stability predictions for rock masses under excavation.

  18. INVESTIGATION OF THE EFFECTS OF DIFFERENT EDGE JOINT ELEMENTS ON DIAGONAL TENSILE STRENGTH IN FURNITURE EDGE JOINTS

    Directory of Open Access Journals (Sweden)

    Arif GÜRAY

    2002-01-01

    Full Text Available In this work, the diagonal tensile strength of furniture edge joints such as wooden dowel, minifix, and alyan screw was investigated in panel-constructed boards for Suntalam and MDF Lam. For this purpose, a diagonal tensile strength test was applied to the 72 samples. According to the results, the maximum diagonal tensile strength was found to be in MDF Lam boards that jointed with alyan screw.

  19. The iliolumbar ligament : its influence on stability of the sacroiliac joint

    NARCIS (Netherlands)

    Pool-Goudzwaard, A.L.; Hoek van Dijke, G; Mulder, P; Spoor, C.W.; Snijders, C.; Stoeckart, R.

    2003-01-01

    STUDY DESIGN: In human specimens the influence of the iliolumbar ligament on sacroiliac joint stability was tested during incremental moments applied to the sacroiliac joints. OBJECTIVES: To assess whether the iliolumbar ligament is able to restrict sacroiliac joint mobility in embalmed cadavers.

  20. Estimation of in-situ joint properties, Naesliden Mine

    Energy Technology Data Exchange (ETDEWEB)

    Barton, N.

    1980-05-15

    Finite element modelling of jointed rock masses requires detailed input data concerning the mechanical behaviour of the relevant joint sets. In the case of the Naesliden project, the properties of the footwall and hanging wall contacts were of particular concern because of their planarity. Methods of estimating the full-scale shear strength and shear stiffness are summarized. The estimates are based on assessment of full-scale values of the joint roughness coefficient (JRC), the joint wall compressive strength (JCS) and the residual friction angle. Sensitivity analyses indicate which of these parameters need to be determined with greatest accuracy at the levels of normal stress of interest. The full-scale estimates are compared with laboratory scale data and with data obtained from small scale tilt tests and tests on model tension fractures. A scale effect makes direct application of laboratory data of doubtful value. A simple dimensionless shear force-displacement formulation is suggested that describes the mobilization and subsequent reduction of joint roughness, as peak strength is exceeded during a given shearing event. The effect of changing normal stress during shearing is accounted for using this method.

  1. Adhesive Joints in Wind Turbine Blades

    DEFF Research Database (Denmark)

    Jørgensen, Jeppe Bjørn

    to be determined in several different ways. The accuracy of different ways of measuring residual stresses in the adhesive was tested by applying five different methods on a single sandwich test specimen (laminate/adhesive/laminate) that was instrumented with strain gauges and fiber Bragg gratings. Quasi...... of the project is to develop new- and to improve the existing design rules for adhesive joints in wind turbine blades. The first scientific studies of adhesive joints were based on stress analysis, which requires that the bond-line is free of defects, but this is rarely the case for a wind turbine blade. Instead...... curing and test temperatures) on the formation of transverse cracks in the adhesive were tested experimentally. It was assumed that the transverse cracks evolved due to a combination of mechanical- and residual stresses in the adhesive. A new approach was developed that allows the residual stress...

  2. Multinuclide digital subtraction imaging in symptomatic prostnetic joints

    International Nuclear Information System (INIS)

    Chafetz, N.; Hattner, R.S.; Ruarke, W.C.; Helms, C.A.; Genant, H.K.; Murray, W.R.

    1985-01-01

    One hundred eleven patients with symptomatic prosthetic joints (86 hips, 23 knees, and two shoulders) were evaluated for prosthetic loosening and infection by combined technetium-99m-MDP/gallium-67 digital subtraction imaging. Clinical correlation was based on the assessment of loosening and bacterial cultures obtained at the time of surgery in 54 patients, joint aspiration cultures obtained in 37 patients, and long-term clinical follow-up for greater than 1.5 years in an additional 15 patients. Results revealed an 80-90% predictive value of a positive test for loosening, and a 95% predictive value of a negative test for infection. However, because of the low sensitivities and specificities observed, this approach to the evaluation of symptomatic prosthetic joints does not seem cost effective

  3. A novel hybrid joining methodology for composite to steel joints

    Science.gov (United States)

    Sarh, Bastian

    This research has established a novel approach for designing, analyzing, and fabricating load bearing structural connections between resin infused composite materials and components made of steel or other metals or alloys. A design philosophy is proposed wherein overlapping joint sections comprised of fiber reinforced plastics (FRP's) and steel members are connected via a combination of adhesive bonding and integrally placed composite pins. A film adhesive is utilized, placed into the dry stack prior to resin infusion and is cured after infusion through either local heat elements or by placing the structure into an oven. The novel manner in which the composite pins are introduced consists of perforating the steel member with holes and placing pre-formed composite pins through them, also prior to resin infusion of the composite section. In this manner joints are co-molded structures such that secondary processing is eliminated. It is shown that such joints blend the structural benefits of adhesive and mechanically connected joints, and that the fabrication process is feasible for low-cost, large-scale production as applicable to the shipbuilding industry. Analysis procedures used for designing such joints are presented consisting of an adhesive joint design theory and a pin placement theory. These analysis tools are used in the design of specimens, specific designs are fabricated, and these evaluated through structural tests. Structural tests include quasi-static loading and low cycle fatigue evaluation. This research has thereby invented a novel philosophy on joints, created the manufacturing technique for fabricating such joints, established simple to apply analysis procedures used in the design of such joints (consisting of both an adhesive and a pin placement analysis), and has validated the methodology through specimen fabrication and testing.

  4. In-field implementation of impedance-based structural health monitoring for insulated rail joints

    Science.gov (United States)

    Albakri, Mohammad I.; Malladi, V. V. N. Sriram; Woolard, Americo G.; Tarazaga, Pablo A.

    2017-04-01

    Track defects are a major safety concern for the railroad industry. Among different track components, insulated rail joints, which are widely used for signaling purposes, are considered a weak link in the railroad track. Several joint-related defects have been identified by the railroad community, including rail wear, torque loss, and joint bar breakage. Current track inspection techniques rely on manual and visual inspection or on specially equipped testing carts, which are costly, timeconsuming, traffic disturbing, and prone to human error. To overcome the aforementioned limitations, the feasibility of utilizing impedance-based structural health monitoring for insulated rail joints is investigated in this work. For this purpose, an insulated joint, provided by Koppers Inc., is instrumented with piezoelectric transducers and assembled with 136 AREA rail plugs. The instrumented joint is then installed and tested at the Facility for Accelerated Service Testing, Transportation Technology Center Inc. The effects of environmental and operating conditions on the measured impedance signatures are investigated through a set of experiments conducted at different temperatures and loading conditions. The capabilities of impedance-based SHM to detect several joint-related damage types are also studied by introducing reversible mechanical defects to different joint components.

  5. Sensorimotor Results from the Joint NASA and Russian Pilot Field Test

    Science.gov (United States)

    Reschke, Millard; Kozlovskaya, I. B.; Kofman, I. S.; Tomilovskaya, E. S.; Cerisano, J. M.; Bloomberg, J. J.; Stenger, M. B.; Lee, S. M. C.; Laurie, S. S.; Rukavishnikov, I. V.; hide

    2016-01-01

    Testing of crew responses following long-duration flights has not previously been possible until a minimum of 24 hours after landing. As a result, it has not been possible to estimate the nonlinear trend of the early (testing at the Soyuz landing site. This research effort has been identified as the Field Test (FT). For operational reasons the FT has been divided into two phases: the full FT and a preliminary pilot version (PFT) of the FT that is reduced in both length and scope. The PFT has now been completed with the landing of the crew of International Space Station Increment 42/43 (Soyuz expedition 41S). RESEARCH: The primary goal of this research was to determine functional abilities associated with long-duration space flight crews beginning as soon after landing as possible (testing in the field and was comprised of a jointly agreed upon subset of tests drawn from the full FT and relied heavily on Russia's Institute of Biomedical Problems Sensory-Motor and Countermeasures Department for content and implementation. Data from the PFT was collected following several ISS missions. Testing on the U.S. side has included: (1) a sit-to-stand test, (2) recovery from a fall stand test where the crewmember begins in the prone position on the ground and then stands for 3.5 minutes while cardiovascular performance and postural ataxia data are acquired, and (3) a tandem heel-to-toe walk test to determine changes in the central locomotor program. Video, cardiovascular parameters (heart rate and blood pressure), data from body-worn inertial sensors, and severity of postflight motion sickness were collected during each test session. In addition our Russian investigators have made measurements associated with: (a) obstacle avoidance, (b) muscle compliance, (c) postural adjustments to perturbations (pushes) applied to the subject's chest area and (d) center of mass measurements made across most test objectives with insoles inserted into the subjects' shoes. Data from 18

  6. Fatigue Life Prediction of Self-Piercing Rivet Joints Between Magnesium and Aluminum Alloys

    Directory of Open Access Journals (Sweden)

    Kang Hong-Tae

    2018-01-01

    Full Text Available Various light materials including aluminum alloys and magnesium alloys are being used to reduce the weight of vehicle structures. Joining of dissimilar materials is always a challenging task to construct a solid structure. Self-piercing rivet (SPR joint is one of various joining methods for dissimilar materials. Front shock tower structures were constructed with magnesium alloy (AM60 joined to aluminum alloy (Al6082 by SPR joints. To evaluate the durability performance of the SPR joints in the structures, fatigue tests of the front shock tower structures were conducted with constant amplitude loadings. Furthermore, this study investigated fatigue life prediction method of SPR joints and compared the fatigue life prediction results with that of experimental results. For fatigue life prediction of the SPR joints in the front shock tower structures, lap-shear and cross-tension specimens of SPR joint were constructed and tested to characterize the fatigue properties of the SPR joint. Then, the SPR joint was represented with area contact method (ACM in finite element (FE models. The load-life curves of the lap-shear and cross-tension specimens were converted to a structural stress-life (S-N curve of the SPR joints. The S-N curve was used to predict fatigue life of SPR joints in the front shock tower structures. The test results and the prediction results were well correlated.

  7. Research of the Resistance of Contact Welding Joint of R65 Type Rail

    Directory of Open Access Journals (Sweden)

    Kęstutis Dauskurdis

    2015-03-01

    Full Text Available In the article the R65 type rail joints that were welded by resistance welding are analysed. Survey methodology of the research consists of the following parts: visual inspection of welded joint, ultrasonic rail inspection, hardness test of upper part of the rail, fusion area research, the measurement hardness test of heat-softened area, the measurement microhardness test, microstructure research of the welded joint, impact strength experiments, chemical analysis of welded joint, wheel-rail interaction research using the finite element method (FEM. The results of the research are analysed and the quality of weld is evaluated. The conclusion is based on the results of this research.

  8. RSRM Nozzle-to-Case Joint J-leg Development

    Science.gov (United States)

    Albrechtsen, Kevin U.; Eddy, Norman F.; Ewing, Mark E.; McGuire, John R.

    2003-01-01

    Since the beginning of the Space Shuttle Reusable Solid Rocket Motor (RSRM) program, nozzle-to-case joint polysulfide adhesive gas paths have occurred on several flight motors. These gas paths have allowed hot motor gases to reach the wiper O-ring. Even though these motors continue to fly safely with this condition, a desire was to reduce such occurrences. The RSRM currently uses a J-leg joint configuration on case field joints and igniter inner and outer joints. The J-leg joint configuration has been successfully demonstrated on numerous RSRM flight and static test motors, eliminating hot gas intrusion to the critical O-ring seals on these joints. Using the proven technology demonstrated on the case field joints and igniter joints, a nozzle-to-case joint J-leg design was developed for implementation on RSRM flight motors. This configuration provides an interference fit with nozzle fixed housing phenolics at assembly, with a series of pressurization gaps incorporated outboard of the joint mating surface to aid in joint pressurization and to eliminate any circumferential flow in this region. The joint insulation is bonded to the nozzle phenolics using the same pressure sensitive adhesive used in the case field joints and igniter joints. An enhancement to the nozzle-to-case joint J-leg configuration is the implementation of a carbon rope thermal barrier. The thermal barrier is located downstream of the joint bondline and is positioned within the joint in a manner where any hot gas intrusion into the joint passes through the thermal barrier, reducing gas temperatures to a level that would not affect O-rings downstream of the thermal barrier. This paper discusses the processes used in reaching a final nozzle-to-case joint J-leg design, provides structural and thermal results in support of the design, and identifies fabrication techniques and demonstrations used in arriving at the final configuration.

  9. Multi-Scale Computational Modeling of Ni-Base Superalloy Brazed Joints for Gas Turbine Applications

    Science.gov (United States)

    Riggs, Bryan

    Brazed joints are commonly used in the manufacture and repair of aerospace components including high temperature gas turbine components made of Ni-base superalloys. For such critical applications, it is becoming increasingly important to account for the mechanical strength and reliability of the brazed joint. However, material properties of brazed joints are not readily available and methods for evaluating joint strength such as those listed in AWS C3.2 have inherent challenges compared with testing bulk materials. In addition, joint strength can be strongly influenced by the degree of interaction between the filler metal (FM) and the base metal (BM), the joint design, and presence of flaws or defects. As a result, there is interest in the development of a multi-scale computational model to predict the overall mechanical behavior and fitness-for-service of brazed joints. Therefore, the aim of this investigation was to generate data and methodology to support such a model for Ni-base superalloy brazed joints with conventional Ni-Cr-B based FMs. Based on a review of the technical literature a multi-scale modeling approach was proposed to predict the overall performance of brazed joints by relating mechanical properties to the brazed joint microstructure. This approach incorporates metallurgical characterization, thermodynamic/kinetic simulations, mechanical testing, fracture mechanics and finite element analysis (FEA) modeling to estimate joint properties based on the initial BM/FM composition and brazing process parameters. Experimental work was carried out in each of these areas to validate the multi-scale approach and develop improved techniques for quantifying brazed joint properties. Two Ni-base superalloys often used in gas turbine applications, Inconel 718 and CMSX-4, were selected for study and vacuum furnace brazed using two common FMs, BNi-2 and BNi-9. Metallurgical characterization of these brazed joints showed two primary microstructural regions; a soft

  10. Evaluation of Rock Joint Coefficients

    Science.gov (United States)

    Audy, Ondřej; Ficker, Tomáš

    2017-10-01

    A computer method for evaluation of rock joint coefficients is described and several applications are presented. The method is based on two absolute numerical indicators that are formed by means of the Fourier replicas of rock joint profiles. The first indicator quantifies the vertical depth of profiles and the second indicator classifies wavy character of profiles. The absolute indicators have replaced the formerly used relative indicators that showed some artificial behavior in some cases. This contribution is focused on practical computations testing the functionality of the newly introduced indicators.

  11. Quantitative metal magnetic memory reliability modeling for welded joints

    Science.gov (United States)

    Xing, Haiyan; Dang, Yongbin; Wang, Ben; Leng, Jiancheng

    2016-03-01

    Metal magnetic memory(MMM) testing has been widely used to detect welded joints. However, load levels, environmental magnetic field, and measurement noises make the MMM data dispersive and bring difficulty to quantitative evaluation. In order to promote the development of quantitative MMM reliability assessment, a new MMM model is presented for welded joints. Steel Q235 welded specimens are tested along the longitudinal and horizontal lines by TSC-2M-8 instrument in the tensile fatigue experiments. The X-ray testing is carried out synchronously to verify the MMM results. It is found that MMM testing can detect the hidden crack earlier than X-ray testing. Moreover, the MMM gradient vector sum K vs is sensitive to the damage degree, especially at early and hidden damage stages. Considering the dispersion of MMM data, the K vs statistical law is investigated, which shows that K vs obeys Gaussian distribution. So K vs is the suitable MMM parameter to establish reliability model of welded joints. At last, the original quantitative MMM reliability model is first presented based on the improved stress strength interference theory. It is shown that the reliability degree R gradually decreases with the decreasing of the residual life ratio T, and the maximal error between prediction reliability degree R 1 and verification reliability degree R 2 is 9.15%. This presented method provides a novel tool of reliability testing and evaluating in practical engineering for welded joints.

  12. JOINT RIGIDITY ASSESSMENT WITH PIEZOELECTRIC WAFERS AND ACOUSTIC WAVES

    International Nuclear Information System (INIS)

    Montoya, Angela C.; Maji, Arup K.

    2010-01-01

    There has been an interest in the development of rapid deployment satellites. In a modular satellite design, different panels of specific functions can be pre-manufactured. The satellite can then be assembled and tested just prior to deployment. Traditional vibration testing is time-consuming and expensive. An alternative test method to evaluate the connection between two plates will be proposed. The method investigated and described employs piezoelectric wafers to induce and sense lamb waves in two aluminum plates, which were joined by steel brackets to form an 'L-Style' joint. Lamb wave behavior and piezoelectric material properties will be discussed; the experimental setup and results will be presented. A set of 4 piezoelectric ceramic wafers were used alternately as source and sensor. The energy transmitted was shown to correlate with a mechanical assessment of the joint, demonstrating that this method of testing is a feasible and reliable way to inspect the rigidity of joints.

  13. Aircraft and ground vehicle friction correlation test results obtained under winter runway conditions during joint FAA/NASA Runway Friction Program

    Science.gov (United States)

    Yager, Thomas J.; Vogler, William A.; Baldasare, Paul

    1988-01-01

    Aircraft and ground vehicle friction data collected during the Joint FAA/NASA Runway Friction Program under winter runway conditions are discussed and test results are summarized. The relationship between the different ground vehicle friction measurements obtained on compacted snow- and ice-covered conditions is defined together with the correlation to aircraft tire friction performance under similar runway conditions.

  14. Experimental analysis of mechanical joints strength by means of energy dissipation

    Science.gov (United States)

    Wolf, Alexander; Lafarge, Remi; Kühn, Tino; Brosius, Alexander

    2018-05-01

    Designing complex structures with the demand for weight reduction leads directly to a multi-material concept. This mixture has to be joined securely and welding, mechanical joining and the usage of adhesives are commonly used for that purpose. Sometimes also a mix of at least two materials is useful to combine the individual advantages. The challenge is the non-destructive testing of these connections because destructive testing requires a lot of preparation and expensive testing equipment. The authors show a testing method by measuring and analysing the energy dissipation in mechanical joints. Known methods are radiography, thermography and ultrasound testing. Unfortunately, the usage of these methods is difficult and often not usable in fibre-reinforced-plastics. The presented approach measures the propagation of the elastic strain wave through the joint. A defined impact strain is detected with by strain-gauges whereby the transmitter is located on one side of the joint and the receiver on the other, respectively. Because of different mechanisms, energy dissipates by passing the joint areas. Main reasons are damping caused by friction and material specific damping. Insufficient performed joints lead to an effect especially in the friction damping. By the measurement of the different strains and the resulting energy loss a statement to the connection quality is given. The possible defect during the execution of the joint can be identified by the energy loss and strain vs. time curve. After the description of the method, the authors present the results of energy dissipation measurements at a bolted assembly with different locking torques. By the adjustable tightening torques for the screw connections easily a variation of the contact pressure can be applied and analysed afterwards. The outlook will give a statement for the usability for other mechanical joints and fibre-reinforced-plastics.

  15. How Do Executive Functions Fit with the Cattell-Horn-Carroll Model? Some Evidence from a Joint Factor Analysis of the Delis-Kaplan Executive Function System and the Woodcock-Johnson III Tests of Cognitive Abilities

    Science.gov (United States)

    Floyd, Randy G.; Bergeron, Renee; Hamilton, Gloria; Parra, Gilbert R.

    2010-01-01

    This study investigated the relations among executive functions and cognitive abilities through a joint exploratory factor analysis and joint confirmatory factor analysis of 25 test scores from the Delis-Kaplan Executive Function System and the Woodcock-Johnson III Tests of Cognitive Abilities. Participants were 100 children and adolescents…

  16. [Development of polyaxial locking plate screw system of sacroiliac joint].

    Science.gov (United States)

    Fan, Weijie; Xie, Xuesong; Zhou, Shuping; Zhang, Yonghu

    2014-09-01

    To develop an instrument for sacroiliac joint fixation with less injury and less complications. Firstly, 18 adult pelvic specimens (8 males and 10 females) were used to measure the anatomical data related to the locking plates and locking screws on the sacrum and ilium, and the polyaxial locking plate screw system of the sacroiliac joint was designed according to the anatomic data. This system was made of medical titanium alloy. Then 4 adult male plevic specimens were harvested and the experiment was divided into 3 groups: group A (normal pelvic), group B (the dislocated sacroiliac joint fixed with sacroiliac screws), and group C (the dislocated sacroiliac joint fixed with polyaxial locking plate screw system). The vertical displacement of sacroiliac joint under the condition of 0-700 N vertical load and the horizontal displacement on angle under the condition of 0-12 N·m torsional load were compared among the 3 groups by using the biological material test system. Finally, the simulated application test was performed on 1 adult male cadaveric specimen to observe soft tissue injury and the position of the locking plate and screw by X-ray films. According to the anatomic data of the sacrum and ilium, the polyaxial locking plate screw system of the sacroiliac joint was designed. The biomechanical results showed that the vertical displacement of the sacroiliac joint under the condition of 0-700 N vertical load in group A was significantly bigger than that in group B and group C (P 0.05). The horizontal displacement on angle under the condition of 0-12 N·m torsional load in group A was significantly less than that in group B and group C (P 0.05). The test of simulating application showed that the specimen suffered less soft tissue injury, and this instrument could be implanted precisely and safely. The polyaxial locking plate screw system of the sacroiliac joint has the advantages of smaller volume and less injury; polyaxial fixation enables flexible adjustment screw

  17. Investigation of corrosion behavior of Mg-steel laser-TIG hybrid lap joints

    International Nuclear Information System (INIS)

    Liu Liming; Xu Rongzheng

    2012-01-01

    Highlights: ► Galvanic corrosion increases the corrosion rate of the Mg-steel joint. ► Fe splashes lower the corrosion resistance of the joint greatly. ► The effect of grain refinement on the corrosion behavior of the joint is slight. ► Ni or Cu interlayer could not improve the corrosion resistance of fusion zone. ► The arc-sprayed coating could enhance the reliability of weld joint. - Abstract: The paper investigates the corrosion behavior of the lap joint of AZ31 magnesium alloy to Q235 steel with salt solution immersion testing and electrochemical testing. It is demonstrated that grain refinement resulting from the welding process has little effect on the corrosion behavior of the lap joint. However, the cathodic phases formed in the welding process and the galvanic corrosion between magnesium alloy and steel decrease the corrosion resistance of the joint greatly. Besides, neither Cu nor Ni, as filler material, could improve the corrosion resistance of the joint, but the arc-sprayed Al coating acting as a protective layer could.

  18. Technology of Welding Joints Mixed with Duplex Steel

    Directory of Open Access Journals (Sweden)

    Słania J.

    2016-03-01

    Full Text Available Results of the examinations of sample plates of mixed joints with the duplex steel were discussed. Examinations were taken on the sample plates of mixed joints of sheet plates type P355NL1 and X2CrNiMoN22-5-3 welded by the flux-cored wire DW-329A by the Kobelco company of the following category T 22 9 3 NL RC/M3 in the gas shroud M21 (Ar+18%CO2 (plate no.1, and nickel covered electrodes E Ni 6082 by the Böhler company (plate no. 2. Results of the side bend test of welded joint, transverse tensile test, stretching of the weld metal, impact strength, micro and macroscopic metallographic examinations, and measurements of the delta ferrite content were presented.

  19. Plantar impact causing midfoot fractures result in higher forces in Chopart's joint than in the ankle joint.

    Science.gov (United States)

    Richter, M; Wippermann, B; Thermann, H; Schroeder, G; Otte, D; Troeger, H D; Krettek, C

    2002-03-01

    Force effect (impact, extent of foot compartment deformation) and result (fracture pattern) for midfoot fractures in car occupants is known. An analysis of the processes in the foot was intended to improve car safety. Eleven fresh, unfrozen, unpreserved intact human cadavers (age: 36.8 (16-61) years, gender: male, race: Caucasian) were studied 24-72 h after death. In 3 cadavers (5 feet) the experimental design was established: entire cadaver fixed on a special tray in supine position, pendulum with bar impactor hitting the foot plantar to Lisfranc's joint. A custom-made pressure sensor was inserted in the ankle (A), talonavicular (TN) and calcaneocuboid (CC) joints (resolution: 1 cm2, sampling rate: 500/s). Sixteen feet were measured: midfoot fractures were induced in 11 feet. The maximum pressure amounted to 1.22-2.55 MPa (2.04+/-0.412) at 0.005 0.195 s (0.067+/-0.059) after impact. The maximum pressure occurred in 8 (50%) cases in the ankle, in 7 (44%) of the TN and 1 (6%) of the CC joints. A comparison of the first 200 pressure samples after impact of all sensor fields resulted in higher forces in Chopart's joint than in the ankle (t-test: p < 0.001). These force differences were higher in cases with midfoot fractures (mixed model analysis of variance: p = 0.003). Due to considerable forces in Chopart's joint we recommend a modification of the actual crash test dummy lower extremity model with an additional load cell that detects forces in the longitudinal direction of the foot axis.

  20. Psychophysical testing of visual prosthetic devices: a call to establish a multi-national joint task force

    Science.gov (United States)

    Rizzo, Joseph F., III; Ayton, Lauren N.

    2014-04-01

    Recent advances in the field of visual prostheses, as showcased in this special feature of Journal of Neural Engineering , have led to promising results from clinical trials of a number of devices. However, as noted by these groups there are many challenges involved in assessing vision of people with profound vision loss. As such, it is important that there is consistency in the methodology and reporting standards for clinical trials of visual prostheses and, indeed, the broader vision restoration research field. Two visual prosthesis research groups, the Boston Retinal Implant Project (BRIP) and Bionic Vision Australia (BVA), have agreed to work cooperatively to establish a multi-national Joint Task Force. The aim of this Task Force will be to develop a consensus statement to guide the methods used to conduct and report psychophysical and clinical results of humans who receive visual prosthetic devices. The overarching goal is to ensure maximum benefit to the implant recipients, not only in the outcomes of the visual prosthesis itself, but also in enabling them to obtain accurate information about this research with ease. The aspiration to develop a Joint Task Force was first promulgated at the inaugural 'The Eye and the Chip' meeting in September 2000. This meeting was established to promote the development of the visual prosthetic field by applying the principles of inclusiveness, openness, and collegiality among the growing body of researchers in this field. These same principles underlie the intent of this Joint Task Force to enhance the quality of psychophysical research within our community. Despite prior efforts, a critical mass of interested parties could not congeal. Renewed interest for developing joint guidelines has developed recently because of a growing awareness of the challenges of obtaining reliable measurements of visual function in patients who are severely visually impaired (in whom testing is inherently noisy), and of the importance of

  1. THE EFFECT OF DEGREASING ON ADHESIVE JOINT STRENGTH

    Directory of Open Access Journals (Sweden)

    Anna Rudawska

    2017-03-01

    Full Text Available The paper investigates the effect of degreasing, a surface preparation methods in adhesive bonding, on adhesive joint strength. 5 types of degreasing agents were used in the study: acetone, extraction naphtha, Ultramyt, Wiko and Loctite 7061. The degreasing operation was performed by three methods: rubbing, spraying and immersion. Strength tests were performed on single-lap adhesive joints of hot-dip galvanized metal sheets made with Loctite 9466 adhesive according to the above variants of surface preparation. The experimental results demonstrate that adhesive joint strength is significantly affected by the applied degreasing agent. Moreover, the method of application of the degreasing agent is crucial, too. The results of strength testing reveal that the most effective degreasing method for hot-dip galvanized metal sheet adhesive joints is spraying using extraction naphtha. Thereby degreased samples have the highest immediate strength and shear strength. The use of extraction naph-tha is also effective in combination with degreasing by rubbing; however, it is not effective when used in combi-nation with immersion, as reflected in the lowest strength results.

  2. Strength of vacuum brazed joints for repair; Haallfasthet hos reparationer utfoerda med vakuumloedning

    Energy Technology Data Exchange (ETDEWEB)

    Berglin, Leif [Siemens Industrial Turbomachinery AB, Finspaang (Sweden)

    2005-04-01

    Strength data are missing for braze joints. Repaired components cannot fully make use of the strength of the braze, and lifetime will be underestimated. The goal of the project was to generate material data to be able to prolong the lifetime of the components. Two different material combinations were tested, 12% Chromium steel brazed with BNi-2, and a nickel base alloy, IN792 brazed with BNi-5. Tensile testing at room temperature and elevated temperature was performed in the project. Target group is purchasers and suppliers of repaired components. A tensile test specimen with butt joint was developed in the project. The used test specimen worked well for the 12% Chromium steel. The results from testing show that proof stress and tensile strength are strongly depending on the joint gap, particularly at room temperature. High strength, close to base material strength, was achieved with joint gaps smaller than 50{mu}m. For wider joint gaps, strength was lower. Strength was approximately 25% of base material strength for joint gaps over 100{mu}m. The results can be explained by changes in microstructure. Joint gaps wider than 50{mu}m showed evidence of two-phase structure. At 500 deg C, the results also showed a connection between joint gap, microstructure and strength. The generated strength data can be used for calculations of lifetime for repaired components. Two different process errors were discovered in the manufacturing process of the brazed IN792 test specimens. The generated material data are therefor erroneous. The reason for this was two manufacturing errors. The tack welding was done with too high heat input. The surfaces of the joint gap became oxidised and the oxide hindered wetting of the braze. The second reason was that the brazing was done without the prescribed hold time at maximum temperature. The melting of the braze was therefor not completed when cooling started. As a result, the strength of the IN792 specimens was low at both temperatures.

  3. Disclosing the temperature of columnar jointing in lavas.

    Science.gov (United States)

    Lamur, Anthony; Lavallée, Yan; Iddon, Fiona E; Hornby, Adrian J; Kendrick, Jackie E; von Aulock, Felix W; Wadsworth, Fabian B

    2018-04-12

    Columnar joints form by cracking during cooling-induced contraction of lava, allowing hydrothermal fluid circulation. A lack of direct observations of their formation has led to ambiguity about the temperature window of jointing and its impact on fluid flow. Here we develop a novel thermo-mechanical experiment to disclose the temperature of columnar jointing in lavas. Using basalts from Eyjafjallajökull volcano (Iceland) we show that contraction during cooling induces stress build-up below the solidus temperature (980 °C), resulting in localised macroscopic failure between 890 and 840 °C. This temperature window for incipient columnar jointing is supported by modelling informed by mechanical testing and thermal expansivity measurements. We demonstrate that columnar jointing takes place well within the solid state of volcanic rocks, and is followed by a nonlinear increase in system permeability of <9 orders of magnitude during cooling. Columnar jointing may promote advective cooling in magmatic-hydrothermal environments and fluid loss during geothermal drilling and thermal stimulation.

  4. Contribution of a multiplex serological test for the preoperative diagnosis of prosthetic joint infection: a prospective study.

    Science.gov (United States)

    de Seynes, Camille; de Barbeyrac, Bertille; Dutronc, Hervé; Ribes, Clément; Crémer, Paul; Dubois, Véronique; Fabre, Thierry; Dupon, Michel; Dauchy, Frédéric-Antoine

    2018-03-22

    Prosthetic joint infection (PJI) is a severe complication of orthopaedic surgery. Preoperative diagnosis, although sometimes difficult, is key to choose the relevant treatment. We conducted a prospective study aimed at evaluating the diagnostic performance of a multiplex serological test for the pre-operative diagnosis of PJI. Blood samples were collected between 1 July 2016 and 31 July 2017 among patients referred for suspected PJI that occurred at least six weeks prior. Infection diagnosis was confirmed using intraoperative bacteriological cultures during prosthetic exchange. Seventy-one patients were included, with a median age of 73 years (interquartile range [IQR]: 66-81) and 40 (56%) were male. Twenty-six patients had aseptic loosening and 45 patients had PJI. Among the latter, median time since the last surgery was 96 weeks (IQR: 20-324). Intraoperative cultures found Staphylococcus spp, Streptococcus spp or both in 39, 5 and 1 patients, respectively. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 81.8, 95.4, 97.3 and 72.4%, respectively, for all patients and 87.5, 93.5, 94.6 and 85.3%, respectively, for staphylococcal infections. Patients with false negative (FN) results had a significantly lower blood lymphocyte count (p = .045). Multiplex serological test performed well among patients with chronic staphylococcal prosthetic infection. This approach could contribute to PJI diagnosis especially in patients for whom the pre-operative analysis of joint fluid is not informative.

  5. Joint pathology and behavioral performance in autoimmune MRL-lpr Mice.

    Science.gov (United States)

    Sakić, B; Szechtman, H; Stead, R H; Denburg, J A

    1996-09-01

    Young autoimmune MRL-lpr mice perform more poorly than age-matched controls in tests of exploration, spatial learning, and emotional reactivity. Impaired behavioral performance coincides temporally with hyperproduction of autoantibodies, infiltration of lymphoid cells into the brain, and mild arthritic-like changes in hind paws. Although CNS mechanisms have been suggested to mediate behavioral deficits, it was not clear whether mild joint pathology significantly affected behavioral performance. Previously we observed that 11-week-old MRL-lpr mice showed a trend for disturbed performance when crossing a narrow beam. The first aim of the present study was to test the significance of this trend by increasing the sample size and, second, to examine the possibility that arthritis-like changes interfere with performance in brief locomotor tasks. For the purpose of the second goal, 18-week-old mice that differ widely in severity of joint disease were selectively taken from the population and tested in beam walking and swimming tasks. It was expected that the severity of joint inflammation would be positively correlated with the degree of locomotor impairment. The larger sample size revealed that young MRL-lpr mice perform significantly more poorly than controls on the beam-walking test, as evidenced by more foot slips and longer traversing time. However, significant correlation between joint pathology scores and measures of locomotion could not be detected. The lack of such relationship suggests that mild joint pathology does not significantly contribute to impaired performance in young, autoimmune MRL-lpr mice tested in short behavioral tasks.

  6. Temporomandibular joint involvement caused by Borrelia Burgdorferi.

    Science.gov (United States)

    Lesnicar, Gorazd; Zerdoner, Danijel

    2007-12-01

    Lyme borreliosis is an endemic disease in Slovenia with an incidence of around 150 patients per 100,000 inhabitants. Although the large joints are most typically affected in Lyme borreliosis, there are also periods of disease activity with arthritis or arthralgias involving smaller joints, including the temporo-mandibular joint. During the years between 2000 and 2003, two patients with Lyme borreliosis affecting the temporo-mandibular joints were treated. The patients presented with fatigue and pain in diverse muscle groups accompanied by arthralgia, which was most pronounced in the temporomandibular joint area. None of the patients were febrile or had joint effusions. Both patients were examined by means of biochemical and serological examinations for Borrelia burgdorferi using ELISA assay and Western blot test (both for IgM and IgG), plain radiographs, MR and CT scans, and scinti-scan of the temporo-mandibular joints They both had positive serum markers for an acute B. burgdorferi infection and were treated with intravenous ceftriaxone. None of the patients had clinical or laboratory signs of chronic Lyme disease activity two and four years following therapy, respectively. Roentgenographic and nuclear magnetic resonance imaging of the temporo-mandibular joints had not shown any persistent sign of acute inflammation. There are only few reports of patients with manifest temporo-mandibular joint involvement of Lyme borreliosis in the literature. This report emphasizes the importance of differential diagnosis of acute temporo-mandibular joint arthralgia, of early diagnosis of Lyme borreliosis, and of the necessity for prompt antibiotic treatment.

  7. Experimental study on joint construction method for aseismatic walls of reactor buildings, (1)

    International Nuclear Information System (INIS)

    Sugita, Kazunao; Mogami, Tatsuo; Ezaki, Tetsuro

    1987-01-01

    On the aseismatic walls of a reactor auxiliary building, many temporary openings are provided at the time of the construction for carrying equipment in later, due to the demand of shortening the construction period. Thus on the aseismatic walls, in most cases there are the joints due to the concrete placed later. As equipment tends to be unitized and become large, the quipment is placed close to the wall having an opening, consequently, the workability is poor, and the standardization of construction method is urgently demanded. The conventional method of closing temporary openings has the problems of safety and connecting reinforcing bars, therefore, the new construction method was proposed. In reactor buildings, the joints of walls are unavoidable, and since those are large scale structures, the joints are numerous. Therefore, at the joint parts, it abandoned and buried frames are used, it is advantageous in the time and cost of joint construction. In both cases, the mechanical properties were confirmed by the fundamental performance test partially modeling the joints and the verifying test modeling the whole walls. In this paper, the test of applying only shearing force to joint models is reported. (Kako, I.)

  8. Physicochemical and microscopic characterization of implant-abutment joints.

    Science.gov (United States)

    Lopes, Patricia A; Carreiro, Adriana F P; Nascimento, Rubens M; Vahey, Brendan R; Henriques, Bruno; Souza, Júlio C M

    2018-01-01

    The purpose of this study was to investigate Morse taper implant-abutment joints by chemical, mechanical, and microscopic analysis. Surfaces of 10 Morse taper implants and the correlated abutments were inspected by field emission gun-scanning electron microscopy (FEG-SEM) before connection. The implant-abutment connections were tightened at 32 Ncm. For microgap evaluation by FEG-SEM, the systems were embedded in epoxy resin and cross-sectioned at a perpendicular plane of the implant-abutment joint. Furthermore, nanoindentation tests and chemical analysis were performed at the implant-abutment joints. Results were statistically analyzed via one-way analysis of variance, with a significance level of P abutment surfaces. The minimum and maximum size of microgaps ranged from 0.5 μm up to 5.6 μm. Furthermore, defects were detected throughout the implant-abutment joint that can, ultimately, affect the microgap size after connection. Nanoindentation tests revealed a higher hardness (4.2 ± 0.4 GPa) for abutment composed of Ti6Al4V alloy when compared to implant composed of commercially pure Grade 4 titanium (3.2 ± 0.4 GPa). Surface defects produced during the machining of both implants and abutments can increase the size of microgaps and promote a misfit of implant-abutment joints. In addition, the mismatch in mechanical properties between abutment and implant can promote the wear of surfaces, affecting the size of microgaps and consequently the performance of the joints during mastication.

  9. Physicochemical and microscopic characterization of implant–abutment joints

    Science.gov (United States)

    Lopes, Patricia A.; Carreiro, Adriana F. P.; Nascimento, Rubens M.; Vahey, Brendan R.; Henriques, Bruno; Souza, Júlio C. M.

    2018-01-01

    Objective: The purpose of this study was to investigate Morse taper implant–abutment joints by chemical, mechanical, and microscopic analysis. Materials and Methods: Surfaces of 10 Morse taper implants and the correlated abutments were inspected by field emission gun-scanning electron microscopy (FEG-SEM) before connection. The implant–abutment connections were tightened at 32 Ncm. For microgap evaluation by FEG-SEM, the systems were embedded in epoxy resin and cross-sectioned at a perpendicular plane of the implant–abutment joint. Furthermore, nanoindentation tests and chemical analysis were performed at the implant–abutment joints. Statistics: Results were statistically analyzed via one-way analysis of variance, with a significance level of P abutment surfaces. The minimum and maximum size of microgaps ranged from 0.5 μm up to 5.6 μm. Furthermore, defects were detected throughout the implant–abutment joint that can, ultimately, affect the microgap size after connection. Nanoindentation tests revealed a higher hardness (4.2 ± 0.4 GPa) for abutment composed of Ti6Al4V alloy when compared to implant composed of commercially pure Grade 4 titanium (3.2 ± 0.4 GPa). Conclusions: Surface defects produced during the machining of both implants and abutments can increase the size of microgaps and promote a misfit of implant–abutment joints. In addition, the mismatch in mechanical properties between abutment and implant can promote the wear of surfaces, affecting the size of microgaps and consequently the performance of the joints during mastication. PMID:29657532

  10. A Probabilistic Damage Tolerance Concept for Welded Joints

    DEFF Research Database (Denmark)

    Lassen, T.; Sørensen, John Dalsgaard

    2002-01-01

    The present paper presents the necessary crack growth statistics and suggests stochastic models for a reliability analysis of the fatigue fracture of welded steel plate joints. The reliability levels are derived from extensive testing with fillet-welded joints for which the entire crack growth...... history has been measured, not only the final fatigue life. The statistics for the time to reach given crack depths are determined. Fracture-mechanics-derived crack growth curves are fitted to the measured experimental curves and the best fit defines the growth parameters involved for each test specimen...

  11. The friction coefficient of shoulder joints remains remarkably low over 24 h of loading.

    Science.gov (United States)

    Jones, Brian K; Durney, Krista M; Hung, Clark T; Ateshian, Gerard A

    2015-11-05

    The frictional response of whole human joints over durations spanning activities of daily living has not been reported previously. This study measured the friction of human glenohumeral joints during 24 h of reciprocal loading in a pendulum testing device, at moderate (0.2 mm/s, 4320 cycles) and low (0.02 mm/s, 432 cycles) sliding speeds, under a 200 N load. The effect of joint congruence was also investigated by testing human humeral heads against significantly larger mature bovine glenoids. Eight human joints and six bovine joints were tested in four combinations: human joints tested at moderate (hHCMS, n=6) and low speed (hHCLS, n=3), human humeral heads tested against bovine glenoids at moderate speed (LCMS, n=3), and bovine joints tested at moderate speed (bHCMS, n=3). In the first half hour the mean±standard deviation of the friction coefficient was hHCMS: 0.0016±0.0011, hHCLS: 0.0012±0.0002, LCMS: 0.0008±0.0002 and bHCMS: 0.0024±0.0008; in the last four hours it was hHCMS: 0.0057±0.0025, hHCLS: 0.0047±0.0017, LCMS: 0.0012±0.0003 and bHCMS: 0.0056±0.0016. The initial value was lower than the final value (pfriction coefficient of natural human shoulders remains remarkably low (averaging as little as 0.0015 and no greater than 0.006) for up to 24 h of continuous loading. The sustained low friction coefficients observed in incongruent joints (~0.001) likely represent rolling rather than sliding friction. Copyright © 2015. Published by Elsevier Ltd.

  12. The Friction Coefficient of Shoulder Joints Remains Remarkably Low Over 24 h of Loading

    Science.gov (United States)

    Jones, Brian K.; Durney, Krista M.; Hung, Clark T.; Ateshian, Gerard A.

    2015-01-01

    The frictional response of whole human joints over durations spanning activities of daily living has not been reported previously. This study measured the friction of human glenohumeral joints during 24 h of reciprocal loading in a pendulum testing device, at moderate (0.2 mm/s, 4320 cycles) and low (0.02 mm/s, 432 cycles) sliding speeds, under a 200 N load. The effect of joint congruence was also investigated by testing human humeral heads against significantly larger mature bovine glenoids. Six human joints and six bovine joints were tested in four combinations: human joints tested at moderate (hHCMS, n=6) and low speed (hHCLS, n=3), human humeral heads tested against bovine glenoids at moderate speed (LCMS, n=3), and bovine joints tested at moderate speed (bHCMS, n=3). In the first half hour the mean ± standard deviation of the friction coefficient was hHCMS: 0.0016±0.0011, hHCLS: 0.0012±0.0002, LCMS: 0.0008±0.0002 and bHCMS: 0.0024±0.0008; in the last four hours it was hHCMS: 0.0057±0.0025, hHCLS: 0.0047±0.0017, LCMS: 0.0012±0.0003 and bHCMS: 0.0056±0.0016. The initial value was lower than the final value (pfriction coefficient of natural human shoulders remains remarkably low (averaging as little as 0.0015 and no greater than 0.006) for up to 24 h of continuous loading. The sustained low friction coefficients observed in incongruent joints (~0.001) likely represent rolling rather than sliding friction. PMID:26472306

  13. Development and validation of the small punch test for UHMWPE used in total joint replacements

    Energy Technology Data Exchange (ETDEWEB)

    Edidin, A.A. [Drexel Univ., Philadelphia, PA (United States). School of Biomedical Engineering, Science and Health Systems; Howmedica Osteonics Corp., Allendale, NJ (United States); Kurtz, S.M. [Drexel Univ., Philadelphia, PA (United States). School of Biomedical Engineering, Science and Health Systems; Thomas Jefferson Univ., Philadelphia, PA (United States). Dept. of Orthopaedic Surgery; Exponent, Inc., Philadelphia, PA (United States)

    2001-07-01

    In order to better understand the mechanical effects of oxidative degradation, improved oxidative stability and crosslinking on ultra-high molecular weight polyethylene (UHMWPE), a unique miniature specimen mechanical testing technique, known as the small punch test, was developed for evaluating total joint replacement components. The small punch test involves deforming a disk-shaped specimen having a thickness of 0.5 mm and a diameter of 6.4 mm. In addition to its small specimen size, the small punch test differs from conventional testing in that deformation of the UHMWPE specimen occurs under multiaxial loading conditions. Using the small punch test, we have traced the evolution of mechanical behavior in UHMWPE after natural (shelf-storage) and accelerated aging conditions. In addition, we have determined relationships between the mechanical behavior of UHMWPE and the biologically relevant wear debris volume generated in total hip replacements. The small punch test has also been used to investigate the effects of radiation crosslinking which has been shown to improve the wear performance in an in vitro hip simulator. However, the crosslinking and subsequent thermal processes used to improve the wear behavior may compromise the native mechanical behavior by changing the ductility and toughness of the UHMWPE bearing. The primary objective of this study was to investigate which tradeoffs exist related to the mechanical behavior associated with various clinically available types of highly crosslinked and thermally treated UHMWPE. We also review the development and validation of the small punch disk bend test and highlight its application to problems of clinical relevance in both hip and knee arthroplasty. (orig.)

  14. Diagnosing patients with longstanding shoulder joint pain

    DEFF Research Database (Denmark)

    Nørregaard, J; Krogsgaard, M R; Lorenzen, T

    2002-01-01

    OBJECTIVE: To examine the interobserver agreement of commonly used clinical tests and diagnoses in patients with shoulder pain, and the accuracy of these tests and ultrasonographic findings in comparison with arthroscopic findings. METHODS: Eighty six patients with longstanding shoulder joint pain...

  15. Long-term neuromuscular training and ankle joint position sense.

    Science.gov (United States)

    Kynsburg, A; Pánics, G; Halasi, T

    2010-06-01

    Preventive effect of proprioceptive training is proven by decreasing injury incidence, but its proprioceptive mechanism is not. Major hypothesis: the training has a positive long-term effect on ankle joint position sense in athletes of a high-risk sport (handball). Ten elite-level female handball-players represented the intervention group (training-group), 10 healthy athletes of other sports formed the control-group. Proprioceptive training was incorporated into the regular training regimen of the training-group. Ankle joint position sense function was measured with the "slope-box" test, first described by Robbins et al. Testing was performed one day before the intervention and 20 months later. Mean absolute estimate errors were processed for statistical analysis. Proprioceptive sensory function improved regarding all four directions with a high significance (pneuromuscular training has improved ankle joint position sense function in the investigated athletes. This joint position sense improvement can be one of the explanations for injury rate reduction effect of neuromuscular training.

  16. Development for dissimilar metal joint between stainless steel and zirconium by explosive bonding technique

    International Nuclear Information System (INIS)

    Onuma, Tsutomu; Matsumoto, Toshimi; Asano, Chooichi; Funamoto, Takao; Hirose, Yasuo; Sasada, Yasuhiro.

    1988-01-01

    Development of dissimilar metal joints between stainless steel and Zr for application to nuclear fuel reprocessing equipment was studied. Two dissimilar metal joints (Zr to SUS 304 L joint and its joint using Ta as insert metal) were made by the explosive bonding technique. After bonding, microstructure, tensile strength and corrosion test of dissimilar metal joints were investigated. The results indicated that: (1) The good dissimilar metal joint is obtained between stainless steel and Zr with a Ta insert metal by using explosive bonding technique. (2) A Ta insert metal retards a growth of intermetallic compounds at the bonding interface. (3) The strength of the dissimilar metal joint in this study is higher than that of Zr metal. Any local attack was not observed at the bonding interface after corrosion test. (author)

  17. Device for measuring hole elongation in a bolted joint

    Science.gov (United States)

    Wichorek, Gregory R. (Inventor)

    1987-01-01

    A device to determine the operable failure mode of mechanically fastened lightweight composite joints by measuring the hole elongation of a bolted joint is disclosed. The double-lap joint test apparatus comprises a stud, a test specimen having a hole, two load transfer plates, and linear displacement measuring instruments. The test specimen is sandwiched between the two load transfer plates and clamped together with the stud. Spacer washers are placed between the test specimen and each load transfer plate to provide a known, controllable area for the determination of clamping forces around the hole of the specimen attributable to bolt torque. The spacer washers also provide a gap for the mounting of reference angles on each side of the test specimen. Under tensile loading, elongation of the hole of the test specimen causes the stud to move away from the reference angles. This displacement is measured by the voltage output of two linear displacement measuring instruments that are attached to the stud and remain in contact with the reference angles throughout the tensile loading. The present invention obviates previous problems in obtaining specimen deformation measurements by monitoring the reference angles to the test specimen and the linear displacement measuring instruments to the stud.

  18. Flat H Redundant Frangible Joint Development

    Science.gov (United States)

    Brown, Chris

    2016-01-01

    Orion and Commercial Crew Program (CCP) Partners have chosen to use frangible joints for certain separation events. The joints currently available are zero failure tolerant and will be used in mission safety applications. The goal is to further develop a NASA designed redundant frangible joint that will lower flight risk and increase reliability. FY16 testing revealed a successful design in subscale straight test specimens that gained efficiency and supports Orion load requirements. Approach / Innovation A design constraint is that the redundant joint must fit within the current Orion architecture, without the need for additional vehicle modification. This limitation required a design that changed the orientation of the expanding tube assemblies (XTAs), by rotating them 90deg from the standard joint configuration. The change is not trivial and affects the fracture mechanism and structural load paths. To address these changes, the design incorporates cantilevered arms on the break plate. The shock transmission and expansion of the XTA applies force to these arms and creates a prying motion to push the plate walls outward to the point of structural failure at the notched section. The 2014 test design revealed that parts could slip during functioning wasting valuable energy needed to separate the structure with only a single XTA functioning. Dual XTA functioning fully separated the assembly showing a discrepancy can be backed up with redundancy. Work on other fully redundant systems outside NASA is limited to a few patents that have not been subjected to functionality testing Design changes to prevent unwanted slippage (with ICA funding in 2015) showed success with a single XTA. The main goal for FY 2016 was to send the new Flat H RFJ to WSTF where single XTA test failures occurred back in 2014. The plan was to gain efficiency in this design by separating the Flat H RFJ with thicker ligaments with dimensions baselined in 2014. Other modifications included geometry

  19. Experimental investigation on full scale RC beam-column joint of NPP structures

    International Nuclear Information System (INIS)

    Thandavamoorthy, T.S.; Lakshmanan, N.; Reddy, G.R.; Kushwaha, H.S.

    2003-01-01

    The Nuclear Power Plant (NPP) structures in India are constructed using reinforced concrete. The beam-column joint in these structures are critical sub-assemblages because they ensure continuity of a structure and transfer forces from one element to another. Under seismic excitation, the beam-column joint region is subjected to horizontal and vertical shear forces whose magnitudes are typically many times higher than those within the adjacent beams and columns. In view of the increased incidence of seismicity in the country, the safety of these structures against earthquake loading assumes greater significance. There is a growing need to look into the seismic safety aspect of existing RC frame type structures in NPPs, which have been designed as per codes prevalent at the time of their construction. Seismic performance of such joints has not been studied extensively in India. Therefore experimental testing of full scale joint identical to those available in the existing NPP structures, was carried out to study its behaviour and evaluate its capacity. The size of the beam of the joint was 2000 mm x 610 mm x 915 mm and column 2915 mm x 610 mm x 915 mm. The percentage reinforcement of the beam was 4.95 and column 1.5. Such full scale and heavily reinforced concrete joint was cast successfully in the laboratory and tested under monotonic loading. The paper presents a complete description of the experimental testing, observations made during testing as for cracking, deflection and rotation of joint, discussion of results obtained, etc. Conclusions drawn from the investigation are also presented. (author)

  20. Experimental and numerical study of Bondura® 6.6 PIN joints

    Science.gov (United States)

    Berkani, I.; Karlsen, Ø.; Lemu, H. G.

    2017-12-01

    Pin joints are widely used in heavy-duty machinery such as aircrafts, cranes and offshore drilling equipment to transfer multi-dimensional shear forces. Their strength and service life depend on the clamping force in the contact region that is provided by interference fits. Though the interference fits provide full contact at the pin-hole interface under pretension loads, the contact interface reduces when the pin is subjected to an external load and hence a smaller contact surface leads to dramatic increase of the contact stress. The PIN joint of Bondura® Technology, investigated in this study, is an innovative solution intended to reduce the slack at the contact surface of the pin joint of heavy-duty machinery by using tapered sleeves on each end of the PIN. The study is aimed to better understand the contact pressure build-up and stress distribution in the supporting contact surface under pre-loading of the joint and the influence of temperature difference between part assembly and operation conditions. Numerical simulation using finite element method and diverse experimental tests were conducted. The numerical simulation and the test results, particularly the tests conducted with lubricated joints, show good conformance.

  1. Investigation of corrosion behavior of Mg-steel laser-TIG hybrid lap joints

    Energy Technology Data Exchange (ETDEWEB)

    Liu Liming, E-mail: liulm@dlut.edu.cn [Key Laboratory of Liaoning Advanced Welding and Joining Technology, School of Materials Science and Engineering, Dalian University of Technology, Dalian 116024 (China); Xu Rongzheng [Key Laboratory of Liaoning Advanced Welding and Joining Technology, School of Materials Science and Engineering, Dalian University of Technology, Dalian 116024 (China)

    2012-01-15

    Highlights: Black-Right-Pointing-Pointer Galvanic corrosion increases the corrosion rate of the Mg-steel joint. Black-Right-Pointing-Pointer Fe splashes lower the corrosion resistance of the joint greatly. Black-Right-Pointing-Pointer The effect of grain refinement on the corrosion behavior of the joint is slight. Black-Right-Pointing-Pointer Ni or Cu interlayer could not improve the corrosion resistance of fusion zone. Black-Right-Pointing-Pointer The arc-sprayed coating could enhance the reliability of weld joint. - Abstract: The paper investigates the corrosion behavior of the lap joint of AZ31 magnesium alloy to Q235 steel with salt solution immersion testing and electrochemical testing. It is demonstrated that grain refinement resulting from the welding process has little effect on the corrosion behavior of the lap joint. However, the cathodic phases formed in the welding process and the galvanic corrosion between magnesium alloy and steel decrease the corrosion resistance of the joint greatly. Besides, neither Cu nor Ni, as filler material, could improve the corrosion resistance of the joint, but the arc-sprayed Al coating acting as a protective layer could.

  2. Experimental investigation on the failure of T-joints at elevated temperature under unaxial loading

    Science.gov (United States)

    Bahri, N. F.; Afendi, M.; Razlan, Z. M.; Nor, A.; Baharuddin, S. A.

    2017-09-01

    In this study, the mechanical properties and maximum failure load of a bulk and T-joints subjected to tensile loading were investigated experimentally. A bulk and the T-joint specimens were fabricated and tested in order to investigate the effects of temperature conditions on the failure of the joints. The adherent and adhesive used for T-joint are 304 L stainless steel and Hysol E 214 HP with the adhesive thickness of 1.0 mm. The tensile test of the bulk specimen and adhesively T-joint were conducted by using a universal testing machine (UTM) at room temperature (RT), 55 °C, 75 °C, 100 °C and 120 °C, respectively. It was found that as the temperature increases, the failure force strength decreases for bulk and T-joint specimen. Data obtained from the tests at 120 °C showed the failure force of the bulk adhesive decreased by approximately 44 % compared to the specimen tested at RT. Next, the bulk of Hysol failure force result was compared with Araldite at RT and 100 °C. Araldite data was taken from the previous study [1]. It has also been found that the bulk for Hysol has higher failure force compared to Araldite at RT and 100 °C.

  3. NASA-DoD Lead-Free Electronics Project. DRAFT Joint Test Report

    Science.gov (United States)

    Kessel, Kurt

    2011-01-01

    . The longer the transition period, the greater the likelihood of Pb-free parts inadvertently being mixed with Pb parts and ending up on what are supposed to be Pb systems. As a result, OEMs, depots, and support contractors need to take action now to either abate the influx of Pb-free parts, or accept it and deal with the likely interim consequences of reduced reliability due to a wide variety of matters, such as Pb contamination, high temperature incompatibility, and tin whiskering. Allowance of Pb-free components produces one of the greatest risks to the reliability of a weapon system. This is due to new and poorly understood failure mechanisms, as well as unknown long-term reliability. If the decision is made to consciously allow Pb-free solder and component finishes into SnPb electronics, additional effort (and cost) will be required to make the significant number of changes to drawings and task order procedures. This project is a follow-on effort to the Joint Council on Aging Aircraft/Joint Group on Pollution Prevention (JCAA/JG-PP) Pb-free Solder Project which was the first group to test the reliability of Pb-free solder joints against the requirements of the aerospace and military community.

  4. Timber joints under long-term loading

    DEFF Research Database (Denmark)

    Feldborg, T.; Johansen, M.

    This report describes tests and results from stiffness and strength testing of splice joints under long-term loading. During two years of loading the spicimens were exposed to cyclically changing relative humidity. After the loading period the specimens were short-term tested. The connectors were...... integral nail-plates and nailed steel and plywood gussets. The report is intended for designers and researchers in timber engineering....

  5. Fatigue crack growth in welded joints in seawater

    Energy Technology Data Exchange (ETDEWEB)

    Lambert, S.B.

    1988-01-01

    A pipe-to-plate specimen has been developed to study the influence of seawater on the fatigue behaviour of welded tubular joints. DC potential drop techniques have been used to detect fatigue crack initiation, and to monitor the subsequent growth of fatigue cracks. Results for three specimens, tested in air are compared with similar data for tubular and T-plate joints. These comparisons indicate that the pipe/plate is a reasonable model of a tubular joint. Testing was performed on a further six specimens in artificial seawater; two each with free corrosion, optimum cathodic protection, and cathodic overprotection. Fatigue life reduction factors compared with corresponding tests in air were 1.8 and 2.8 for free corrosion, 1.7 and 1.1 with cathodic protection, and 4.2 and 3.3 with cathodic over-protection. These fatigue life reduction factors were comparable to results on T-plate specimens, and were strongly dependent on crack shape development. Linear elastic fracture mechanics techniques appear suitable for the calculation of fatigue crack propagation life. Three approximate solution techniques for crack tip stress intensity factors show reasonable agreement with experimentally derived values. It is recommended that forcing functions be used to model crack aspect ratio development in welded joints. Such forcing functions are influenced by the initial stress distribution and the environment. 207 refs., 192 figs., 22 tabs.

  6. Damage behavior of SnAgCu/Cu solder joints subjected to thermomechanical cycling

    International Nuclear Information System (INIS)

    Xiao, H.; Li, X.Y.; Hu, Y.; Guo, F.; Shi, Y.W.

    2013-01-01

    Highlights: •A creep–fatigue damage model based on CDM was proposed. •Designed system includes load frame, strain measure device and damage test device. •Damage evolution of solder joints was a function of accumulated inelastic strain. •Damage of solder joints is an interaction between creep and low-cycle fatigue. -- Abstract: Thermomechanical fatigue damage is a progressive process of material degradation. The objective of this study was to investigate the damage behavior of SnAgCu/Cu solder joints under thermomechanical cycling. A damage model was proposed based on continuum damage mechanics (CDM). Based upon an analysis of displacements for flip-chip solder joints subjected to thermal cycling, a special bimetallic loading frame with single-solder joint samples was designed to simulate the service conditions of actual joints in electronic packages. The assembly, which allowed for strain measurements of an individual solder joint during temperature cycling, was used to investigate the impact of stress–strain cycling on the damage behavior of SnAgCu/Cu solder joints. The characteristic parameters of the damage model were determined through thermomechanical cycling and strain measurement tests. The damage variable D = 1 − R 0 /R was selected, and values for it were obtained using a four-probe method for the single-solder joint samples every dozen cycles during thermomechanical cycling tests to verify the model. The results showed that the predicted damage was in good agreement with the experimental results. The damage evolution law proposed here is a function of inelastic strain, and the results showed that the damage rate of SnAgCu/Cu solder joints increased as the range of the applied strain increased. In addition, the microstructure evolution of the solder joints was analyzed using scanning electron microscopy, which provided the microscopic explanation for the damage evolution law of SnAgCu/Cu solder joints

  7. Damage behavior of SnAgCu/Cu solder joints subjected to thermomechanical cycling

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, H., E-mail: xiaohui2013@yahoo.com.cn; Li, X.Y.; Hu, Y.; Guo, F.; Shi, Y.W.

    2013-11-25

    Highlights: •A creep–fatigue damage model based on CDM was proposed. •Designed system includes load frame, strain measure device and damage test device. •Damage evolution of solder joints was a function of accumulated inelastic strain. •Damage of solder joints is an interaction between creep and low-cycle fatigue. -- Abstract: Thermomechanical fatigue damage is a progressive process of material degradation. The objective of this study was to investigate the damage behavior of SnAgCu/Cu solder joints under thermomechanical cycling. A damage model was proposed based on continuum damage mechanics (CDM). Based upon an analysis of displacements for flip-chip solder joints subjected to thermal cycling, a special bimetallic loading frame with single-solder joint samples was designed to simulate the service conditions of actual joints in electronic packages. The assembly, which allowed for strain measurements of an individual solder joint during temperature cycling, was used to investigate the impact of stress–strain cycling on the damage behavior of SnAgCu/Cu solder joints. The characteristic parameters of the damage model were determined through thermomechanical cycling and strain measurement tests. The damage variable D = 1 − R{sub 0}/R was selected, and values for it were obtained using a four-probe method for the single-solder joint samples every dozen cycles during thermomechanical cycling tests to verify the model. The results showed that the predicted damage was in good agreement with the experimental results. The damage evolution law proposed here is a function of inelastic strain, and the results showed that the damage rate of SnAgCu/Cu solder joints increased as the range of the applied strain increased. In addition, the microstructure evolution of the solder joints was analyzed using scanning electron microscopy, which provided the microscopic explanation for the damage evolution law of SnAgCu/Cu solder joints.

  8. An Accelerated Testing Approach for Automated Vehicles with Background Traffic Described by Joint Distributions

    OpenAIRE

    Huang, Zhiyuan; Lam, Henry; Zhao, Ding

    2017-01-01

    This paper proposes a new framework based on joint statistical models for evaluating risks of automated vehicles in a naturalistic driving environment. The previous studies on the Accelerated Evaluation for automated vehicles are extended from multi-independent-variate models to joint statistics. The proposed toolkit includes exploration of the rare event (e.g. crash) sets and construction of accelerated distributions for Gaussian Mixture models using Importance Sampling techniques. Furthermo...

  9. Temporomandibular joint space in children without joint disease

    International Nuclear Information System (INIS)

    Larheim, T.A.

    1981-01-01

    Bilateral assessment of the temporomandibular joint space in children without joint disease is reported. Twenty-eight children were examined with conventional radiography and 23 with tomography. High prevalence of asymmetric joint spaces with both techniques indicated that great care should be taken when using narrowing or widening of the joint space as a diagnostic criterion in children with juvenile rheumatoid arthritis. Other signs, such as restricted translation of the mandibular head, and clinical symptoms should be evaluated. (Auth.)

  10. High Level Architecture Runtime Infrastructure Test Report

    National Research Council Canada - National Science Library

    Wright, Darrell

    1998-01-01

    Joint Advanced Distributed Simulation Joint Test and Evaluation is an Office of the Secretary of Defense-sponsored joint test force chartered to determine the utility of advanced distributed simulation (ADS...

  11. A nondestructive, reproducible method of measuring joint reaction force at the distal radioulnar joint.

    Science.gov (United States)

    Canham, Colin D; Schreck, Michael J; Maqsoodi, Noorullah; Doolittle, Madison; Olles, Mark; Elfar, John C

    2015-06-01

    To develop a nondestructive method of measuring distal radioulnar joint (DRUJ) joint reaction force (JRF) that preserves all periarticular soft tissues and more accurately reflects in vivo conditions. Eight fresh-frozen human cadaveric limbs were obtained. A threaded Steinmann pin was placed in the middle of the lateral side of the distal radius transverse to the DRUJ. A second pin was placed into the middle of the medial side of the distal ulna colinear to the distal radial pin. Specimens were mounted onto a tensile testing machine using a custom fixture. A uniaxial distracting force was applied across the DRUJ while force and displacement were simultaneously measured. Force-displacement curves were generated and a best-fit polynomial was solved to determine JRF. All force-displacement curves demonstrated an initial high slope where relatively large forces were required to distract the joint. This ended with an inflection point followed by a linear area with a low slope, where small increases in force generated larger amounts of distraction. Each sample was measured 3 times and there was high reproducibility between repeated measurements. The average baseline DRUJ JRF was 7.5 N (n = 8). This study describes a reproducible method of measuring DRUJ reaction forces that preserves all periarticular stabilizing structures. This technique of JRF measurement may also be suited for applications in the small joints of the wrist and hand. Changes in JRF can alter native joint mechanics and lead to pathology. Reliable methods of measuring these forces are important for determining how pathology and surgical interventions affect joint biomechanics. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  12. Reliability aspects of a composite bolted scarf joint. [in wing skin splice

    Science.gov (United States)

    Reed, D. L.; Eisenmann, J. R.

    1975-01-01

    The design, fabrication, static test, and fatigue test of both tension and compression graphite-epoxy candidates for a wing splice representative of a next-generation transport aircraft was the objective of the reported research program. A single-scarf bolted joint was selected as the design concept. Test specimens were designed and fabricated to represent an upper-surface and a lower-surface panel containing the splice. The load spectrum was a flight-by-flight random-load history including ground-air-ground loads. The results of the fatigue testing indicate that, for this type of joint, the inherent fatigue resistance of the laminate is reflected in the joint behavior and, consequently, the rate of damage accumulation is very slow under realistic fatigue loadings.

  13. Microstructural characterization and properties of dissimilar joints between stainless steels done by fusion process

    International Nuclear Information System (INIS)

    Bauly, Julio Cesar

    2000-01-01

    The chemical, mechanical and microstructural characterization of a dissimilar joint between SA-336 class F347 austenitic and SA-479 type 414 martensitic stainless steels were done, welded by GTAW process. The results of the tensile strength of the joint welded with the consumable ER Ni Cr-3, showed higher values compared to those of the base metal SA-336 class F347 of lower resistance in the dissimilar joint. These results were complemented by longitudinal bends tests, susceptibility to intergranular attack tests, hardness tests, optical microscopy, scanning electron microscopy and chemical analysis. That characterization compared to the one of dissimilar joint welded with ER309L consumable, submitted to the same mentioned tests, leads to the conclusion that the consumable of nickel ERNiCr-3 seems to be the best applicable consumable, compared the ER309L. The main welding parameters were also obtained, in order to compose a database for a future qualification of the welding procedure. Besides, situations possible to be joint in this type of joint, were simulated, such as its weldability using the laser processing, joint welded without material addition and without root protection with inert gas. The results of the tensile strength of these welded joint, showed values superior to the base metal SA-336 class F347 of lower resistance in the dissimilar joint. These results were complemented by hardness tests and chemical analysis, also confirming that these simulated situations assist to the values of the strength of the joint, even if diverging with the theoretical studies done with the application of the Schaeffler Diagram as well as with the well known weldability techniques for this type of dissimilar joint. A theoretical discussion was also done, using the Schaeffler Diagram, with base in a review of the literature, where the welding needs was analyzed with or without metal addition, using the values of chemical composition of the base metals and specified

  14. Analysis of Using Acoustic Microscopy to Evaluate Defects in Spot Welding Joints

    Directory of Open Access Journals (Sweden)

    Korzeniowski M.

    2016-06-01

    Full Text Available The article presents the possibilities of using acoustic microscopy to evaluate defects in resistance spot welding joints. For this purpose, the welded joints were made from two grades of aluminium plates EN AW5754 H24 and EN AW6005 T606, which were then subjected to non-destructive testing using acoustic microscopy and conventional destructive testing using traditional light microscopy techniques. Additionally, the study examined the influence of the typical contaminants found in industrial conditions on the quality of the joint.

  15. Comparative effectiveness of open versus minimally invasive sacroiliac joint fusion

    Directory of Open Access Journals (Sweden)

    Ledonio CGT

    2014-06-01

    Full Text Available Charles GT Ledonio,1 David W Polly Jr,1 Marc F Swiontkowski,1 John T Cummings Jr2 1Department of Orthopaedic Surgery, University of Minnesota, Twin Cities, MN, 2Community Neurosurgical Care, Indianapolis, IN, USA Background: The mainstay of sacroiliac joint disruption/degenerative sacroiliitis therapy has been nonoperative management. This nonoperative management often includes a regimen of physical therapy, chiropractic treatment, therapeutic injections, and possibly radiofrequency ablation at the discretion of the treating physician. When these clinical treatments fail, sacroiliac joint fusion has been recommended as the standard treatment. Open and minimally invasive (MIS surgical techniques are typical procedures. This study aims to compare the perioperative measures and Oswestry Disability Index (ODI outcomes associated with each of these techniques. Methods: A comparative retrospective chart review of patients with sacroiliac joint fusion and a minimum of 1 year of follow-up was performed. Perioperative measures and ODI scores were compared using the Fisher's exact test and two nonparametric tests, ie, the Mann–Whitney U test and the Wilcoxon signed-rank test. The results are presented as percent or median with range, as appropriate. Results: Forty-nine patients from two institutions underwent sacroiliac joint fusion between 2006 and 2012. Ten patients were excluded because of incomplete data, leaving 39 evaluable patients, of whom 22 underwent open and 17 underwent MIS sacroiliac joint fusion. The MIS group was significantly older (median age 66 [39–82] years than the open group (median age 51 [34–74] years. Surgical time and hospital stay were significantly shorter in the MIS group than in the open group. Preoperative ODI was significantly greater in the open group (median 64 [44–78] than in the MIS group (median 53 [14–84]. Postoperative improvement in ODI was statistically significant within and between groups, with MIS

  16. The ITER EC H and CD upper launcher: Design, analysis and testing of a bolted joint for the Blanket Shield Module

    Energy Technology Data Exchange (ETDEWEB)

    Gessner, Robby, E-mail: robby.gessner@kit.edu [Karlsruhe Institute of Technology, Institute for Applied Materials, P.O. Box 3640, D-76021 Karlsruhe (Germany); Aiello, Gaetano; Grossetti, Giovanni; Meier, Andreas [Karlsruhe Institute of Technology, Institute for Applied Materials, P.O. Box 3640, D-76021 Karlsruhe (Germany); Ronden, Dennis [DIFFER – Dutch Institute for Fundamental Energy Physics, P.O. Box 1207, NL-3430 BE Nieuwegein (Netherlands); Spaeh, Peter; Scherer, Theo; Schreck, Sabine; Strauss, Dirk; Vaccaro, Alessandro [Karlsruhe Institute of Technology, Institute for Applied Materials, P.O. Box 3640, D-76021 Karlsruhe (Germany)

    2013-10-15

    Highlights: ► The BSM of the ECH Launcher is attached to the Launcher Main Frame by a bolted joint. ► The bolts were designed as “captive” in order to avoid their accidental removal from the joint. ► The bolted flange connection using two sets of 15 captive bolts (M22 × 2) placed along the sides. ► The captive bolt design is based on a concept that uses a dedicated spring ring, a standard spiral spring and a tensioning screw with two threads to secure the bolts in a form-locking stop. -- Abstract: The final design of the structural system for the ITER EC H and CD upper launcher is in progress. Many design features of the preliminary design are under revision with the aim to achieve the built-to-print-status. This paper deals with design and analysis of a bolted joint for the Blanket Shield Module with special perspective on Remote Handling capability. The BSM of the ECH Launcher is attached to the Launcher Main Frame by a bolted joint conceived so that in the Hot Cell Facility, RH maintenance can be performed on internal components. The joint must be capable to resist very high Electro-Magnetic loads from disruptions, while it has to sustain substantial thermal cycling during operation. Thus the need for a rigid and reliable design is essential. Beside the set of pre-stressed bolts the flanges were therefore equipped with additional shear keys to divert radial moments away from the bolts. Main focus of the work performed was the mechanical design of the joint and the assessment of the structural integrity with respect to the loads applied and its capability for maintenance by RH procedures. To fulfill a major aspect of the RH requirements, the bolts were designed as “captive” in order to avoid their accidental removal from the joint. The captive bolt design is based on a concept that uses a dedicated spring ring, a standard spiral spring and a tensioning screw with two threads to secure the bolts in a form-locking stop. The final approval phase of

  17. The ITER EC H and CD upper launcher: Design, analysis and testing of a bolted joint for the Blanket Shield Module

    International Nuclear Information System (INIS)

    Gessner, Robby; Aiello, Gaetano; Grossetti, Giovanni; Meier, Andreas; Ronden, Dennis; Spaeh, Peter; Scherer, Theo; Schreck, Sabine; Strauss, Dirk; Vaccaro, Alessandro

    2013-01-01

    Highlights: ► The BSM of the ECH Launcher is attached to the Launcher Main Frame by a bolted joint. ► The bolts were designed as “captive” in order to avoid their accidental removal from the joint. ► The bolted flange connection using two sets of 15 captive bolts (M22 × 2) placed along the sides. ► The captive bolt design is based on a concept that uses a dedicated spring ring, a standard spiral spring and a tensioning screw with two threads to secure the bolts in a form-locking stop. -- Abstract: The final design of the structural system for the ITER EC H and CD upper launcher is in progress. Many design features of the preliminary design are under revision with the aim to achieve the built-to-print-status. This paper deals with design and analysis of a bolted joint for the Blanket Shield Module with special perspective on Remote Handling capability. The BSM of the ECH Launcher is attached to the Launcher Main Frame by a bolted joint conceived so that in the Hot Cell Facility, RH maintenance can be performed on internal components. The joint must be capable to resist very high Electro-Magnetic loads from disruptions, while it has to sustain substantial thermal cycling during operation. Thus the need for a rigid and reliable design is essential. Beside the set of pre-stressed bolts the flanges were therefore equipped with additional shear keys to divert radial moments away from the bolts. Main focus of the work performed was the mechanical design of the joint and the assessment of the structural integrity with respect to the loads applied and its capability for maintenance by RH procedures. To fulfill a major aspect of the RH requirements, the bolts were designed as “captive” in order to avoid their accidental removal from the joint. The captive bolt design is based on a concept that uses a dedicated spring ring, a standard spiral spring and a tensioning screw with two threads to secure the bolts in a form-locking stop. The final approval phase of

  18. Glass-aluminium bonded joints ; testing, comparing and designing for the ATP

    NARCIS (Netherlands)

    Richemont, S.A.J. de; Veer, F.A.

    2007-01-01

    This article presents the research to the bonded joints of the All Transparent Pavilion (ATP), an experimental project built in November 2004 at the faculty of Architecture in Delft. The pavilion is designed to use structural glass elements, bonded with Delo Photobond GB 368, a photo-catalytic

  19. Intelligent screening of electrofusion-polyethylene joints based on a thermal NDT method

    Science.gov (United States)

    Doaei, Marjan; Tavallali, M. Sadegh

    2018-05-01

    The combinations of infrared thermal images and artificial intelligence methods have opened new avenues for pushing the boundaries of available testing methods. Hence, in the current study, a novel thermal non-destructive testing method for polyethylene electrofusion joints was combined with k-means clustering algorithms as an intelligent screening tool. The experiments focused on ovality of pipes in the coupler, as well as misalignment of pipes-couplers in 25 mm diameter joints. The temperature responses of each joint to an internal heat pulse were recorded by an IR thermal camera, and further processed to identify the faulty joints. The results represented clustering accuracy of 92%, as well as more than 90% abnormality detection capabilities.

  20. Comparative effectiveness of open versus minimally invasive sacroiliac joint fusion.

    Science.gov (United States)

    Ledonio, Charles Gt; Polly, David W; Swiontkowski, Marc F; Cummings, John T

    2014-01-01

    The mainstay of sacroiliac joint disruption/degenerative sacroiliitis therapy has been nonoperative management. This nonoperative management often includes a regimen of physical therapy, chiropractic treatment, therapeutic injections, and possibly radiofrequency ablation at the discretion of the treating physician. When these clinical treatments fail, sacroiliac joint fusion has been recommended as the standard treatment. Open and minimally invasive (MIS) surgical techniques are typical procedures. This study aims to compare the perioperative measures and Oswestry Disability Index (ODI) outcomes associated with each of these techniques. A comparative retrospective chart review of patients with sacroiliac joint fusion and a minimum of 1 year of follow-up was performed. Perioperative measures and ODI scores were compared using the Fisher's exact test and two nonparametric tests, ie, the Mann-Whitney U test and the Wilcoxon signed-rank test. The results are presented as percent or median with range, as appropriate. Forty-nine patients from two institutions underwent sacroiliac joint fusion between 2006 and 2012. Ten patients were excluded because of incomplete data, leaving 39 evaluable patients, of whom 22 underwent open and 17 underwent MIS sacroiliac joint fusion. The MIS group was significantly older (median age 66 [39-82] years) than the open group (median age 51 [34-74] years). Surgical time and hospital stay were significantly shorter in the MIS group than in the open group. Preoperative ODI was significantly greater in the open group (median 64 [44-78]) than in the MIS group (median 53 [14-84]). Postoperative improvement in ODI was statistically significant within and between groups, with MIS resulting in greater improvement. The open and MIS sacroiliac joint fusion techniques resulted in statistically and clinically significant improvement for patients with degenerative sacroiliitis refractory to nonoperative management. However, the number of patients

  1. Heat Resistance of Glued Finger Joints in Spruce Wood Constructions

    Directory of Open Access Journals (Sweden)

    Martin Sviták

    2014-10-01

    Full Text Available The heat resistance of glued spruce wood was evaluated for different joint types and adhesives. Bending strength, modulus of elasticity, and also fracture evaluation were investigated on glued spruce samples made by the finger-jointed principle. Finger-jointed samples were glued with polyurethane (PUR and melamine-urea-formaldehyde (MUF adhesives. Heat loading was realized at temperatures 60, 80, and 110 °C and compared with wood with 20 °C. A static bending test with four-point flexural test was used. Elevated temperature and adhesive type had an important influence on the bending strength. On the other hand, adhesive type had a significant influence on the modulus of elasticity, but elevated temperature had no substantial influence.

  2. Characteristics of the joint mini-model high temperature superconducting cable

    International Nuclear Information System (INIS)

    Kim, H.; Sim, K.; Cho, J.; Kim, S.; Kim, J.H.; Jung, H.Y.

    2008-01-01

    To obtain realistic data on the high temperature superconducting (HTS) power cable, 3-phase 100 m long, 22.9 kV class HTS power transmission cable system have been developed by Korea Electrotechnology Research Institute (KERI) and LS cable Ltd. that is one of 21st Century Frontier Project in Korea. This cable was installed at Go-chang testing site of Korea Electric Power Corporation (KEPCO). For the application of the HTS power cable joint is very important to ensure the performance. Therefore, this paper gives some investigation of AC loss, critical current and joint resistance in jointed HTS tape. We experimentally showed that the influence of joint resistance on AC loss by using several joint methods. Finally, we are measured critical current, AC loss and jointed resistance for the manufactured mini-model cable

  3. Application of the continuously-yielding joint model for studying disposal of high-level nuclear waste in crystalline rock

    International Nuclear Information System (INIS)

    Hakala, M.; Johansson, E.; Simonen, A.

    1993-04-01

    The non-linear Continuously-Yielding (CY) joint model and its use in numerical analyses of a nuclear waste repository are studied in the report. On major advantage of using CY-model is that laboratory test results, if available, can directly be used in analyses thus reducing uncertainties about joint input parameters. The new testing machine MTS-815 of Helsinki University of Technology was used to determine the joint behaviour of some granitic joints from the depth of 400-600 m below the ground surface. The procedure for triaxial joint tests was refined during this work. Two programs called NormFit and SherFit were developed and tested to determine the best fit parameter values for CY-model from laboratory test results

  4. Obesity and worsening of chronic venous disease and joint mobility.

    Science.gov (United States)

    Belczak, Cleusa Ema Quilici; de Godoy, José Maria Pereira; Belzack, Sergio Quilici; Ramos, Rubiana Neves; Caffaro, Roberto Augusto

    2014-09-01

    The aim of this study was to investigate a possible relationship between obesity and decreased mobility of the talocrural joint and in turn chronic venous disease. One hundred obese patients recruited at Hospital Santa Casa de Maringa, Parana were enrolled by order of arrival at the hospital in a randomized quantitative cross-sectional study. Inclusion criteria were patients with a body mass index above 30 kg/m(2) and the exclusion criteria were infectious conditions that would interfere with the assessment. Patients were graded according to the clinical, etiological, anatomical and pathophysiological classification. Talocrural goniometry was performed to assess the degree of mobility of the legs. The Kolmogorov-Smirnov normality test, Kruskal-Wallis test, Dunn's Multiple comparison test and analysis of variance were used for statistical analysis tests with an alpha error of 5% being considered acceptable. The increase in body mass index is correlated to the reduction in joint mobility (Kruskal-Wallis test: p-value Kruskal-Wallis test: p-value <0.0001). Obesity is associated with deterioration in joint mobility and worsening of chronic venous disease. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  5. Metallographic observations of AISI 304 - copper dissimular joints

    International Nuclear Information System (INIS)

    Medeiros, R.C. de; Carvalho Perdigao, S. de

    1982-01-01

    The current work informs on the SMAW dissimilar joints embrittled by molten Copper. Bead on plate of that metal were deposited on four different base metals to evaluate the phenomena. Conventional and non conventional welding methods were employed to obtain dissimilar joints of AISI 304-Cu. The latter were observed metallographically. These results are to be complemented by mechanical testing actually being performed. (Author) [pt

  6. Ultrasonic guided wave inspection of Inconel 625 brazed lap joints

    Science.gov (United States)

    Comot, Pierre; Bocher, Philippe; Belanger, Pierre

    2016-04-01

    The aerospace industry has been investigating the use of brazing for structural joints, as a mean of reducing cost and weight. There therefore is a need for a rapid, robust, and cost-effective non-destructive testing method for evaluating the structural integrity of the joints. The mechanical strength of brazed joints depends mainly on the amount of brittle phases in their microstructure. Ultrasonic guided waves offer the possibility of detecting brittle phases in joints using spatio-temporal measurements. Moreover, they offer the opportunity to inspect complex shape joints. This study focused on the development of a technique based on ultrasonic guided waves for the inspection of Inconel 625 lap joints brazed with BNi-2 filler metal. A finite element model of a lap joint was used to optimize the inspection parameters and assess the feasibility of detecting the amount of brittle phases in the joint. A finite element parametric study simulating the input signal shape, the center frequency, and the excitation direction was performed. The simulations showed that the ultrasonic guided wave energy transmitted through, and reflected from, the joints was proportional to the amount of brittle phases in the joint.

  7. Joint Replacement (Finger and Wrist Joints)

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Joint Replacement Email to a friend * required fields ...

  8. Joint Operation Planning

    National Research Council Canada - National Science Library

    2006-01-01

    .... It sets forth joint doctrine to govern the joint operation planning activities and performance of the Armed Forces of the United States in joint operations, and provides the joint doctrinal basis...

  9. Jointness for the Rest of Us: Reforming Joint Professional Development

    Science.gov (United States)

    2016-06-10

    transferred to the Joint Staff. 13 DOD’s instinct to “overly centralize planning, organization, and management.”20 The authors contend that this...2. 3 John F. Schank and others, Who is Joint? Reevaluating the Joint Duty Assignment List : A Study Prepared for the Joint Staff, by the RAND...and code those billets as such. Once identified, DOD must expand the Joint Duty Assignment List (JDAL) to include billets that offer enlisted personnel

  10. Unexplained lower abdominal pain associated with sacroiliac joint dysfunction: report of 2 cases.

    Science.gov (United States)

    Morimoto, Daijiro; Isu, Toyohiko; Kim, Kyongsong; Matsumoto, Ryoji; Isobe, Masanori

    2011-01-01

    A 25-year-old woman and a 31-year-old man presented with chronic lower back pain and unexplained lower abdominal pain. Both patients had groin tenderness at the medial border of the anterior superior iliac spine. The results of radiographical and physical examinations suggested sacroiliac joint dysfunction. Sacroiliac joint injection relieved their symptoms, including groin tenderness. In our experience, groin tenderness is highly specific for sacroiliac joint dysfunction. We speculate that spasm of the iliac muscle can cause groin pain and tenderness. Groin pain and a history of unexplained abdominal pain, with lower back pain, are symptoms that suggest sacroiliac joint dysfunction. Additionally, compression of the iliac muscle is a simple and useful maneuver; therefore, it can be used as a screening test for sacroiliac joint dysfunction, alongside other provocation tests.

  11. Quality control/quality assurance testing for joint density and segregation of asphalt mixtures : tech transfer summary.

    Science.gov (United States)

    2013-04-01

    A longitudinal joint is the interface between two adjacent and parallel hot-mix asphalt (HMA) mats. Inadequate joint construction can lead to a location where water can penetrate the pavement layers and reduce the structural support of the underlying...

  12. Periprosthetic joint infection: are patients with multiple prosthetic joints at risk?

    Science.gov (United States)

    Jafari, S Mehdi; Casper, David S; Restrepo, Camilo; Zmistowski, Benjamin; Parvizi, Javad; Sharkey, Peter F

    2012-06-01

    Patients who present with a periprosthetic joint infection in a single joint may have multiple prosthetic joints. The risk of these patients developing a subsequent infection in another prosthetic joint is unknown. Our purposes were (1) to identify the risk of developing a subsequent infection in another prosthetic joint and (2) to describe the time span and organism profile to the second prosthetic infection. We retrospectively identified 55 patients with periprosthetic joint infection who had another prosthetic joint in place at the time of presentation. Of the 55 patients, 11 (20%) developed a periprosthetic joint infection in a second joint. The type of organism was the same as the first infection in 4 (36%) of 11 patients. The time to developing a second infection averaged 2.0 years (range, 0-6.9 years). Copyright © 2012 Elsevier Inc. All rights reserved.

  13. Benign joint hypermobility syndrome in soldiers; what is the effect of military training courses on associated joint instabilities?

    Directory of Open Access Journals (Sweden)

    Kamran Azma

    2014-01-01

    Full Text Available Background: Hypermobile joints are joints with beyond normal range of motion and may be associated with joint derangements. This study aimed to evaluate the prevalence of benign joint hypermobility syndrome (BJHS among soldiers and effect of training courses on related joint instabilities. Materials and Methods: In a prospective cohort study on 721 soldiers of Iran Army in Isfahan in 2013 the prevalence of joint hypermobility was obtained by using Beighton criteria. Soldiers divided in two groups of healthy and suffered based on their scores. The prevalence of ankle sprain, shoulder and temporomandibular joint (TMJ dislocations identified before beginning service by history-taking and reviewing paraclinical documents. After 3 months of military training, a recent occurrence of mentioned diseases was revaluated in two groups. The collected data were analyzed using SPSS-20 software using Independent-T and Chi-square tests. Results: The frequency of BJHS before military training was 29.4%. After passing military training period, the incidence of ankle sprain was significantly higher in suffered group achieving the minimum Beighton score (BS of 4 (4.3%, P = 0.03, 5 (5.5%, P = 0.005 and also 6 out of 9 (6.5%, P = 0.01. The incidence of TMJ dislocation was not significantly different based on a minimum score of 4, while it was higher in suffered group when considering the score of 5 (2.1% and 6 (2.6% for discrimination of two groups (P = 0.03. There was no significant difference between two groups in case of shoulder dislocation anyway. Conclusion: Military training can increase the incidence of ankle sprains and TMJ dislocations in hypermobility persons with higher BS in comparison with healthy people. Therefore, screening of joint hypermobility may be useful in identifying individuals at increased risk for joint instabilities.

  14. Hybrid FSWeld-bonded joint fatigue behaviour

    Science.gov (United States)

    Lertora, Enrico; Mandolfino, Chiara; Gambaro, Carla; Pizzorni, Marco

    2018-05-01

    Aluminium alloys, widely used in aeronautics, are increasingly involved in the automotive industry due to the good relationship between mechanical strength and specific weight. The lightening of the structures is the first objective, which allows the decreasing in the weight in motion. The use of aluminium alloys has also seen the introduction of the Friction Stir Welding (FSW) technique for the production of structural overlapping joints. FSW allows us to weld overlap joints free from defects, but with the presence of a structural notch further aggravated by the presence of a "hook" defect near the edge of the weld. Furthermore, FSW presents a weld penetration area connected to the tool geometry and penetration. The experimental activity will be focused on the combination of two different joining techniques, which can synergistically improve the final joint resistance. In particular, the welding and bonding process most commonly known as weld-bonding is defined as a hybrid process, as it combines two different junction processes. In this paper we analyse FSWelded AA6082 aluminium alloy overlapped joint with the aim of quantitatively evaluating the improvement provided by the presence of an epoxy adhesive between the plates. After optimising the weld-bonding process, the mechanical behaviour of welded joints will be analysed by static and dynamic tests. The presence of the adhesive should limit the negative effect of the structural notch inevitable in a FSW overlapped joint.

  15. Coracoclavicular joint

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kun Sang; Park, Chan Il; Ahn, Jae Doo; Lim, Chong Won [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1970-10-15

    The coracoclvicular joint, a rear abnormality which may be the cause of pain in the shoulder and limitation of motion of the shoulder joint, is discussed. A case of coracoclvicular joint with shoulder pain was observed in 65 yrs old Korean male.

  16. Effect of Ti interlayer on the bonding quality of W and steel HIP joint

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Ji-Chao [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, 230031 (China); Science Island Branch of Graduate School, University of Science & Technology of China, Hefei, 230031 (China); Wang, Wanjing, E-mail: wjwang@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, 230031 (China); Wei, Ran; Wang, Xingli; Sun, Zhaoxuan [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, 230031 (China); Science Island Branch of Graduate School, University of Science & Technology of China, Hefei, 230031 (China); Xie, Chunyi; Li, Qiang [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, 230031 (China); Luo, Guang-Nan [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, 230031 (China); Science Island Branch of Graduate School, University of Science & Technology of China, Hefei, 230031 (China); Hefei Center for Physical Science and Technology, Hefei, 230022 (China); Hefei Science Center of Chinese Academy of Sciences, Hefei, 230027 (China)

    2017-03-15

    Tungsten (W) and steel bonding is one of the key technologies for blanket First Wall (FW) manufacture in thermal fusion reactor. The W/Steel joints are prone to fail without interlayer for the different thermo physical properties. To study the effect of titanium (Ti) interlayer on the bonding quality of W and steel joints, W/Steel Hot Isostatic Pressing (HIP) experiments with Ti interlayer were conducted under 930 °C, 100 MPa for 2 h. Intermetallics caused by atom interdiffusion would affect the bonding quality of W/Ti/Steel HIP joints, the bonding quality was evaluated by microstructure analysis and mechanical tests. All the HIP joints were well bonded and results showed no intermetallics occurred between W/Ti interfaces, meanwhile multiply phases were found between Ti/Steel interfaces. Shear tests indicated when Ti thickness was 100–500 μm, the maximum shear strength of W/Ti/Steel HIP joints would be up to around 151 MPa. Charpy impact tests showed the W/Ti/Steel HIP joints all broke in a brittle manner and the maximum Charpy impact energy was ∼0.192 J. Nano-indentation tests demonstrated W/Ti interfaces could be enhanced by solid solution hardening and formation of brittle phases has conducted high hardness across the Ti/Steel interfaces.

  17. Stiffness Coefficients of Mortise and Tenon Joints used on Wooden Window Profiles

    Directory of Open Access Journals (Sweden)

    Milan Podlena

    2016-04-01

    Full Text Available Samples of corner joints of wooden rectangular windows, with widths of 78 and 92 mm, were used to determine the stiffness of tenon and mortise joints. Two series of samples were loaded statically in the angular plane of compression and tension, so that the bending moment could be derived. The objective of the experiment was to determine the existing correlations between the stiffness in maximum strength and the stiffness in the elastic area for both types of tests. After strength tests were carried out, the annual ring width of the samples was measured to determine whether this factor affects the stiffness of the joints. The results showed that there was a relatively strong correlation between the stiffness in the elastic area and the maximum load. A two-factor analysis of variance confirmed that the type of load did not affect the stiffness of the joint, but the type of joint (width does significantly affect the stiffness. Therefore, the width of annual rings was positively correlated with the stiffness of the joints.

  18. Analysis of in-situ rock joint strength using digital borehole scanner images

    Energy Technology Data Exchange (ETDEWEB)

    Thapa, Bhaskar Bahadur [Univ. of California, Berkeley, CA (United States)

    1994-09-01

    The availability of high resolution digital images of borehole walls using the Borehole Scanner System has made it possible to develop new methods of in-situ rock characterization. This thesis addresses particularly new approaches to the characterization of in-situ joint strength arising from surface roughness. An image processing technique is used to extract the roughness profile from joints in the unrolled image of the borehole wall. A method for estimating in-situ Rengers envelopes using this data is presented along with results from using the method on joints in a borehole in porphyritic granite. Next, an analysis of the joint dilation angle anisotropy is described and applied to the porphyritic granite joints. The results indicate that the dilation angle of the joints studied are anisotropic at small scales and tend to reflect joint waviness as scale increases. A procedure to unroll the opposing roughness profiles to obtain a two dimensional sample is presented. The measurement of apertures during this process is shown to produce an error which increases with the dip of the joint. The two dimensional sample of opposing profiles is used in a new kinematic analysis of the joint shear stress-shear deformation behavior. Examples of applying these methods on the porphyritic granite joints are presented. The unrolled opposing profiles were used in a numerical simulation of a direct shear test using Discontinuous Deformation Analysis. Results were compared to laboratory test results using core samples containing the same joints. The simulated dilatancy and shear stress-shear deformation curves were close to the laboratory curves in the case of a joint in porphyritic granite.

  19. Experimental study of metal gasketed joints for ultra-high vacuums; Etude experimentale de joints metalliques pour ultra-vide

    Energy Technology Data Exchange (ETDEWEB)

    Boulloud, J. P.; Schweitzer, J. [Commissariat a l' energie atomique et aux energies alternatives - CEA, Service de Physique Appliquee, groupe de Vide, Centre d' Etudes Nucleaires de Saclay (France)

    1960-07-01

    Various type of leak-tight metal joints have been studied with their application in assemblies containing total vacuums in mind. Their integrity has been tested with a helium leak detector, and leaks of about 2 x 10{sup -12} cm{sup 3} Atm/s per meter of joint have been measured, simultaneously with the clamping effort applied at the joint and the deformation of the metal gasket. The integrity to clamping effort ratio curve is not retraced in reverse upon relaxation of the clamping effort, but a 'return curve' analogous to a hysteresis cycle explains why certain types of joint retain their integrity at high temperatures. The use of a tracer gas permits discrimination between external permeation of the joint and gas from occlusions between its mating surfaces. The authors have been led to consider that neither the nature nor the purity or surface condition of the joint have any basic influence on its integrity. Clamping effort values in respect of various joints and necessary for total integrity are indicated. Reprint of a paper published in Le vide, no. 82, Jul-Aug 1959 [French] L'etude de differents types de joints metalliques etanches, en vue de leur application a l'ultra-vide, a ete effectuee a l'aide d'un detecteur de fuite a helium. On a mesure simultanement le debit de fuite, l'effort applique sur le joint et sa deformation. On a reussi a mesurer des debits de fuite de l'ordre de 2 x 10{sup -12} cm{sup 3} Atm/s/m de joint pour l'air. La courbe de l'etancheite en fonction de l'effort applique n'est pas reversible et on a pu mettre en evidence un 'cycle d'hysteresis' qui explique que certains joints conservent leur etancheite a haute temperature. La methode de mesure d'etancheite au moyen d'un gaz traceur a amene a faire une distinction entre la permeation et le degazage des gaz occlus dans l'interface des joints et a considerer que ni la nature, ni la purete et ni l'etat de surface du joint n'ont une influence primordiale sur l'etancheite de joint. Des valeurs

  20. Temporomandibular joint

    International Nuclear Information System (INIS)

    Westesson, P.L.; Hatala, M.; Tallents, R.H.; Katzberg, R.W.; Musgrave, M.; Levitt, S.

    1990-01-01

    This paper determines the frequency of MR signs of abnormal temporomandibular joints (TMJs) in asymptomatic volunteers. Forty-two volunteers with 84 clinically normal TMJs were imaged in the sagittal and coronal planes with surface coil MR imaging. Sagittal closed and open and coronal closed views were obtained bilaterally in all volunteers. The images were classified as normal (superior disk position) or abnormal (disk displacement of degenerative joint disease). Eighteen joints in 11 volunteers were abnormal; 12 had disk displacement with reduction and six had disk displacement without reduction, with associated degenerative joint disease in three of the six. Asymptomatic internal derangement and degenerative joint disease occur in about one-fourth of asymptomatic volunteers

  1. Degenerative Changes of the Facet Joints in Adults With Lumbar Spondylolysis.

    Science.gov (United States)

    Goda, Yuichiro; Sakai, Toshinori; Harada, Taihei; Takao, Shoichiro; Takata, Yoichiro; Higashino, Kosaku; Harada, Masafumi; Sairyo, Koichi

    2017-07-01

    Radiologic analysis using computed tomography. To analyze the degenerative changes of the facet joints in patients with spondylolysis in comparison with control subjects. Defects of the pars interarticularis are thought to result in a reduction of biomechanical stress on adjacent facet joints. Therefore, degenerative changes of the facet joints in patients with spondylolysis are expected to be less than those in patients without spondylolysis. Abdominal and pelvic multidetector computed tomography scans of 2000 subjects, performed for conditions unrelated to low back pain, were reviewed. A total of 107 patients (37 women and 70 men) with L5 spondylolysis were identified [spondylolysis (+) group]. Sex-matched and age-matched controls without spondylolysis were chosen randomly [spondylolysis (-) group]. Subjects in the spondylolysis group were subdivided into either bilateral spondylolysis or unilateral spondylolysis groups for comparison with the control group. Four radiologic findings (narrowing, sclerosis, osteophyte, and bone cyst) indicative of degenerative change of the facet joints adjacent to the L5 pars defects were evaluated and the degree of degenerative change was graded by summing the number of degenerative changes (score range, 0-4). The χ test and Mann-Whitney U test were used for statistical analysis. Significantly more degenerative changes in both L4/L5 and L5/S facet joints were found in the spondylolysis (+) group than in the spondylolysis (-) group (χ test, P spondylolysis (+) group than in the spondylolysis (-) group. Degenerative changes of the facet joints at both L4/L5 and L5/S were more severe in the unilateral spondylolysis (+) group than in the spondylolysis (-) group. Degenerative changes of the facet joints in patients with lumbar spondylolysis were more severe than those without spondylolysis.

  2. Mechanical behaviour of Astm A 297 grade Hp joints welded using different processes

    International Nuclear Information System (INIS)

    Emygdio, Paulo Roberto Oliveira; Zeemann, Annelise; Almeida, Luiz Henrique de

    1996-01-01

    The influence of different arc welding processes on mechanical behaviour was studied for cast heat resistant stainless steel welded joints, in the as welded conditions. ASTM A 297 grade HP with niobium and niobium/titanium additions were welded following three different welding procedures, using shielded metal arc welding gas tungsten arc welding and plasma arc welding, in six welded joints. The welded joint mechanical behaviour was evaluated by ambient temperature and 870 deg C tensile tests; and creep tests at 900 deg C and 50 MPa. Mechanical test results showed that the welding procedure qualification following welding codes is not suitable for high temperature service applications. (author)

  3. Experimental Investigation of the Influence of Joint Geometric Configurations on the Mechanical Properties of Intermittent Jointed Rock Models Under Cyclic Uniaxial Compression

    Science.gov (United States)

    Liu, Yi; Dai, Feng; Fan, Pengxian; Xu, Nuwen; Dong, Lu

    2017-06-01

    Intermittent joints in rock mass are quite sensitive to cyclic loading conditions. Understanding the fatigue mechanical properties of jointed rocks is beneficial for rational design and stability analysis of rock engineering projects. This study experimentally investigated the influences of joint geometry (i.e., dip angle, persistency, density and spacing) on the fatigue mechanism of synthetic jointed rock models. Our results revealed that the stress-strain curve of jointed rock under cyclic loadings is dominated by its curve under monotonic uniaxial loadings; the terminal strain in fatigue curve is equal to the post-peak strain corresponding to the maximum cyclic stress in the monotonic stress-strain curve. The four joint geometrical parameters studied significantly affect the fatigue properties of jointed rocks, including the irreversible strains, the fatigue deformation modulus, the energy evolution, the damage variable and the crack coalescence patterns. The higher the values of the geometrical parameters, the lower the elastic energy stores in this jointed rock, the higher the fatigue damage accumulates in the first few cycles, and the lower the fatigue life. The elastic energy has certain storage limitation, at which the fatigue failure occurs. Two basic micro-cracks, i.e., tensile wing crack and shear crack, are observed in cyclic loading and unloading tests, which are controlled principally by joint dip angle and persistency. In general, shear cracks only occur in the jointed rock with higher dip angle or higher persistency, and the jointed rock is characterized by lower fatigue strength, larger damage variable and lower fatigue life.

  4. A personalized 3D-printed prosthetic joint replacement for the human temporomandibular joint: From implant design to implantation.

    Science.gov (United States)

    Ackland, David C; Robinson, Dale; Redhead, Michael; Lee, Peter Vee Sin; Moskaljuk, Adrian; Dimitroulis, George

    2017-05-01

    Personalized prosthetic joint replacements have important applications in cases of complex bone and joint conditions where the shape and size of off-the-shelf components may not be adequate. The objective of this study was to design, test and fabricate a personalized 3D-printed prosthesis for a patient requiring total joint replacement surgery of the temporomandibular joint (TMJ). The new 'Melbourne' prosthetic TMJ design featured a condylar component sized specifically to the patient and fixation screw positions that avoid potential intra-operative damage to the mandibular nerve. The Melbourne prosthetic TMJ was developed for a 58-year-old female recipient with end-stage osteoarthritis of the TMJ. The load response of the prosthesis during chewing and a maximum-force bite was quantified using a personalized musculoskeletal model of the patient's masticatory system developed using medical images. The simulations were then repeated after implantation of the Biomet Microfixation prosthetic TMJ, an established stock device. The maximum condylar stresses, screw stress and mandibular stress at the screw-bone interface were lower in the Melbourne prosthetic TMJ (259.6MPa, 312.9MPa and 198.4MPa, respectively) than those in the Biomet Microfixation device (284.0MPa, 416.0MPa and 262.2MPa, respectively) during the maximum-force bite, with similar trends also observed during the chewing bite. After trialing surgical placement and evaluating prosthetic TMJ stability using cadaveric specimens, the prosthesis was fabricated using 3D printing, sterilized, and implanted into the female recipient. Six months post-operatively, the prosthesis recipient had a normal jaw opening distance (40.0 mm), with no complications identified. The new design features and immediate load response of the Melbourne prosthetic TMJ suggests that it may provide improved clinical and biomechanical joint function compared to a commonly used stock device, and reduce risk of intra-operative nerve damage

  5. [Compensatory joints at the pelvis (author's transl)].

    Science.gov (United States)

    Schumacher, G; Weber, M

    1980-10-01

    An osteochondrosis ischio-pubica represents a "testing site" for the integrity of the pelvis not only during child age but in adults as well. If all naturally available compensatory mechanisms have been exhausted especially following a change of range of motion in the pelvis ring structure, fatigue fractures or zones in transformation in the area typical of osteochondrosis ischio-pubica may appear. These fractures or transformation zones respectively to our mind have joint character, because they are capable of temporarily replacing lost mobility of physiological joints. Healing is achieved through rest, muscular balance and a specific physiotherapy. The purpose of this muscular training is to cushion all unphysiological motions in the pelvis and to support and boost the function of those joints still well preserved.

  6. [Joint diagnostic value of four temperature sensation tests in elderly patients with type 2 diabetic peripheral neuropathy].

    Science.gov (United States)

    Guo, Wei; Li, Yun-Ming; Ai, Zhi-Hua; You, Zhi-Qing; Wan, Yong; Cheng, Ying; Lang, Hong-Mei

    2013-07-01

    To explore the joint diagnostic value of four temperature sensation tests in elderly patients with type 2 diabetic peripheral neuropathy. Thermal sensory analyzer-II were applied to measure cool sensation (CS), warm sensation (WS), cold pain sensation (CP)and heat pain sensation (HP) of 308 elderly patients with type 2 diabetes. Logistic regression model was adopted to create the new variable Temp4 from four temperature sensation tests to diagnose type 2 diabetic peripheral neuropathy. The ROC curve analysis was used to determine the best cut-off points of the four temperature sensation and Temp4, and the diagnostic value of it was evaluated. The means of temperature sensation tests of the diabetic peripheral neuropathy (DPN) group were significantly different from those of the non-DPN group (P sensation tests to diagnose the DPN, the sensitivity of WS test was the highest, and the value was 0.710; but the specificity, positive predictive value, negative predictive value, Youden index, diagnostic accuracy and Kappa value of cold sensation test were the highest, and the values were 0.842, 0.746, 0.799, 0.528, 77.92% and 0.535, respectively; the Kappa values of the other three temperature sensation tests were all greater than 0.4 (P sensation tests (P sensation quantitative tests were in good agreementand could be applied to diagnose DPN; the new variable Temp4 could be used for diagnosis of DPN with a higher diagnostic accuracy.

  7. The joint verification experiments as a global non-proliferation exercise

    International Nuclear Information System (INIS)

    Shaner, J.W.

    1998-01-01

    This conference commemorates the 10th anniversary of the second of two Joint Verification Experiments conducted by the Soviet Union and the US. These two experiments, one at the Nevada test site in the US, and the second here at the Semipalatinsk test site were designed to test the verification of a nuclear testing treaty limiting the size underground explosions to 150 kilotons. By building trust and technical respect between the weapons scientists of the two most powerful adversaries, the Joint Verification Experiment (JVE) had the unanticipated result of initiating a suite of cooperative projects and programs aimed at reducing the Cold War threats and preventing the proliferation of weapons of mass destruction

  8. Bending stress modeling of dismountable furniture joints applied with a use of finite element method

    Directory of Open Access Journals (Sweden)

    Milan Šimek

    2009-01-01

    Full Text Available Presented work focuses on bending moment stress modeling of dismountable furniture joints with a use of Finite Element Method. The joints are created from Minifix and Rondorfix cams combined with non-glued wooden dowels. Laminated particleboard 18 mm of thickness is used as a connected material. The connectors were chosen such as the most applied kind in furniture industry for the case furniture. All gained results were reciprocally compared to each other and also in comparison to experimental testing by the mean of stiffness. The non-linear numerical model of chosen joints was successfully created using the software Ansys Workbench. The detailed analysis of stress distribution in the joint was achieved with non-linear numerical simulation. A relationship between numerical si­mu­la­tion and experimental testing was showed by comparison stiffness tangents. A numerical simulation of RTA joint loads also demonstrated the important role of non-glued dowels in the tested joints. The low strength of particleboard in the tension parallel to surface (internal bond is the most likely the cause of the joint failure. Results are applicable for strength designing of furniture with the aid of Computer Aided Engineering.

  9. Pilot Sensorimotor and Cardiovascular Results from the Joint Russian/U.S. Field Test

    Science.gov (United States)

    Reschke, M. F.; Kozlovskaya, I. B.; Kofman, I. S.; Tomilovskya, E. S.; Cerisano, J. M.; Bloomberg, J. J.; Stenger, M. B.; Platts, S. H.; Rukavishnikov, I. V.; Fomina, E. V.; hide

    2014-01-01

    The primary goal of this research is to determine functional abilities associated with long-duration space flight crews beginning as soon after landing as possible (test in conjunction with postural ataxia testing (quiet stance sway) as well as cardiovascular responses during the other functional tasks. In addition to the immediate post-landing collection of data for the full FT, postflight data is being acquired twice more within the 24 hours after landing and will continue over the subsequent weeks until functional sensorimotor and cardiovascular responses have returned to preflight normative values. The PFT represents a initial evaluation of the feasibility of testing in the field, and is comprised of a jointly agreed upon subset of tests from the full FT and relies heavily on Russia's Institute of Biomedical Problems Sensory-Motor and Countermeasures Laboratories for content and implementation. The PFT has been collected on several ISS missions. Testing on the U.S. side has included: (1) a sit-to-stand test, (2) recovery from a fall where the crewmember began in the prone position on the ground and then stood for 3 minutes while cardiovascular stability was determined and postural ataxia data were acquired, and (3) a tandem heel-to-toe walk test to determine changes in the central locomotor program. Video, cardiovascular parameters (heart rate and blood pressure), data from bodyworn inertial sensors, and severity of postflight motion sickness were collected during each test session. Our Russian investigators have added measurements associated with: (a) obstacle avoidance, (b) muscle compliance and (c) postural adjustments to perturbations (push) applied to the subject's chest area. The level of functional deficit observed in the crew tested to date is typically beyond what was expected and is clearly triggered by the acquisition of gravity loads immediately after landing when the demands for crew intervention in response to emergency operations will be greatest

  10. Joint resistance measurements of pancake and terminal joints for JT-60SA EF coils

    Energy Technology Data Exchange (ETDEWEB)

    Obana, Tetsuhiro, E-mail: obana.tetsuhiro@LHD.nifs.ac.jp [National Institute for Fusion Science, 322-6 Oroshi, Toki, Gifu 509-5292 (Japan); Takahata, Kazuya; Hamaguchi, Shinji; Mito, Toshiyuki; Imagawa, Shinsaku [National Institute for Fusion Science, 322-6 Oroshi, Toki, Gifu 509-5292 (Japan); Kizu, Kaname; Murakami, Haruyuki; Yoshida, Kiyoshi [Japan Atomic Energy Agency, 801-1 Mukoyama, Naka, Ibaraki 311-0193 (Japan)

    2013-11-15

    Highlights: • To evaluate the joint fabrication technology for the JT-60SA EF coils, joint resistance measurements were conducted with a joint sample. • The joint sample was composed of pancake and terminal joints. • The measurements demonstrated that both joints fulfilled the design requirement. • Considering the measurements, the characteristics of both joints were investigated using an analytical model that represents the joints. -- Abstract: To evaluate the joint fabrication technology for the JT-60SA EF coils, joint resistance measurements were conducted using a sample consisting of pancake and terminal joints. Both joints are shake-hands lap joints composed of cable-in-conduit conductors and a pure copper saddle-shaped spacer. The measurements demonstrated that both joints fulfilled the design requirement. Considering these measurements, the characteristics of both joints were investigated using analytical models that represent the joints. The analyses indicated that the characteristics of the conductors used in the joints affect the characteristics of the joints.

  11. Joint Inversion of Direct Current Resistivity and Seismic Refraction Data

    International Nuclear Information System (INIS)

    Kurt, B.B.

    2007-01-01

    In this study, I assumed the underground consist of horizontal layers. I developed one-dimensional (1D) Direct Current Resistivity (DCR) and seismic refraction inversion code using MATLAB package and attempt to find velocity, resistivity and depth of the layers. The code uses damped least square technique. The code can do inversion on DCR and seismic data either individually or jointly. I tested the joint inversion code on synthetic data. Eventually, I saw that the result of joint inversion is better than the result of individual inversions. The joint inversion found depth of models of each layer and, in addition, velocity and resistivity closer to real values

  12. Disability in Patients With Trapeziometacarpal Joint Arthrosis: Incidental Versus Presenting Diagnosis

    NARCIS (Netherlands)

    Becker, Stéphanie J. E.; Makarawung, Dennis J. S.; Spit, Silke A.; King, John D.; Ring, David

    2014-01-01

    Purpose To test the hypothesis that there is no difference in trapeziometacarpal (TMC) joint arthrosis-related symptoms and disability between patients seeking treatment for symptoms of TMC arthrosis and those with incidental TMC joint arthrosis. Methods We compared 64 patients presenting for care

  13. Joint instability and osteoarthritis.

    Science.gov (United States)

    Blalock, Darryl; Miller, Andrew; Tilley, Michael; Wang, Jinxi

    2015-01-01

    Joint instability creates a clinical and economic burden in the health care system. Injuries and disorders that directly damage the joint structure or lead to joint instability are highly associated with osteoarthritis (OA). Thus, understanding the physiology of joint stability and the mechanisms of joint instability-induced OA is of clinical significance. The first section of this review discusses the structure and function of major joint tissues, including periarticular muscles, which play a significant role in joint stability. Because the knee, ankle, and shoulder joints demonstrate a high incidence of ligament injury and joint instability, the second section summarizes the mechanisms of ligament injury-associated joint instability of these joints. The final section highlights the recent advances in the understanding of the mechanical and biological mechanisms of joint instability-induced OA. These advances may lead to new opportunities for clinical intervention in the prevention and early treatment of OA.

  14. LMFBR flexible pipe joint development program. Annual technical progress report, government fiscal year 1977

    International Nuclear Information System (INIS)

    1978-01-01

    Currently, the ASME Boiler and Pressure Vessel Code does not allow the use of flexible pipe joints (bellows) in Section III, Class 1 reactor primary piping systems. Studies have shown that the primary piping loops of LMFBR's could be simplified by using these joints. This simplification translates directly into shorter primary piping runs and reduced costs for the primary piping system. Further cost savings result through reduced vault sizes and reduced containment building diameter. In addition, the use of flexible joints localizes the motions from thermally-induced piping growth into components which are specifically designed to accommodate this motion. This reduces the stress levels in the piping system and its components. It is thus economically and structurally important that flexible piping joints be available to the LMFBR designer. The overall objective of the Flexible Joint Program is to provide this availability. This will be accomplished through the development of ASME rules which allow the appropriate use of such joints in Section III, Class 1 piping systems and through the development and demonstration of construction methods which satisfy these rules. The rule development includes analytic and testing methodology formulations which will be supported by subscale bellows testing. The construction development and demonstration encompass the design, fabrication, and in-sodium testing of prototypical LMFBR plant-size flexible pipe joints which meet all ASME rule requirements. The satisfactory completion of these developmental goals will result in an approved flexible pipe joint design for the LMFBR. Progress is summarized in the following efforts undertaken during 1977 to accomplish these goals: (1) code case support, (2) engineering and design, (3) material development, (4) testing, and (5) manufacturing development

  15. Elbow helical axes of motion are not the same in physiologic and kinetic joint simulators.

    Science.gov (United States)

    Muriuki, Muturi G; Mohagheh-Motlagh, Amin; Smolinski, Patrick J; Miller, Mark Carl

    2012-08-31

    Physiologic and kinetic joint simulators have been widely used for investigations of joint mechanics. The two types of simulator differ in the way joint motion is achieved; through prescribed motions and/or forces in kinetic joint simulators and by tendon loads in physiologic joint simulators. These two testing modalities have produced important insights, as in elucidating the importance of soft tissue structures to joint stability. However, the equivalence of the modalities has not been tested. This study sequentially tested five cadaveric elbows using both a physiologic simulator and a robot/6DOF system. Using position data from markers on the humerus and ulna, we calculated and compared the helical axes of motion of the specimens as the elbows were flexed from full extension. Six step size increments were used in the helical axis calculation. Marker position data at each test's full extension and full flexion point were also used to calculate a datum (overall) helical axis. The angles between the datum axis and step-wise movements were computed and stored. Increasing step size monotonically decreased the variability and the average conical angle encompassing the helical axes; a repeated measures ANOVA using test type (robot or physiologic simulator) and step size found that both type and step caused statistically significant differences (p<0.001). The large changes in helical axis angle observed for small changes in elbow flexion angle, especially in the robot tests, are a caveat for investigators using similar control algorithms. Controllers may need to include increased joint compliance and/or C(1) continuity to reduce variability. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Design and technology parameters influence on durability for heat exchangers tube to tubesheet joints

    Science.gov (United States)

    Ripeanu, R. G.

    2017-02-01

    The main failures of heat exchangers are: corrosion of tubes and jacket, tubes blockage and failures of tube to tubesheet joints also by corrosion. The most critical zone is tube to tubesheet joints. Depending on types of tube to tubesheet joints, in order to better respect conditions of tension and compression, this paper analyses the tubesheet holes shapes, smooth and with a grove, on corrosion behavior. In the case of welding tubes with tubesheet, welding parameters modify corrosion behavior. Were realized welded joints by three welding regimes and tested at corrosion in two media, tap water and industrial water. Were tested also samples made of smooth tubes, finned tubes and tubes coated with a passive product as applied by a heat exchanger manufacturer. For all samples, the roughness parameters were measured, before and after the corrosion tests. The obtained corrosion rates show that stress values and their distribution along the joint modify the corrosion behavior. The optimum welding parameters were established in order to increase the joint durability. The paper has shown that passive product used is not proper chosen and the technology of obtaining rolled thread pipes diminishes tubes’ durability by increasing the corrosion rate.

  17. Joint Instability and Osteoarthritis

    Directory of Open Access Journals (Sweden)

    Darryl Blalock

    2015-01-01

    Full Text Available Joint instability creates a clinical and economic burden in the health care system. Injuries and disorders that directly damage the joint structure or lead to joint instability are highly associated with osteoarthritis (OA. Thus, understanding the physiology of joint stability and the mechanisms of joint instability-induced OA is of clinical significance. The first section of this review discusses the structure and function of major joint tissues, including periarticular muscles, which play a significant role in joint stability. Because the knee, ankle, and shoulder joints demonstrate a high incidence of ligament injury and joint instability, the second section summarizes the mechanisms of ligament injury-associated joint instability of these joints. The final section highlights the recent advances in the understanding of the mechanical and biological mechanisms of joint instability-induced OA. These advances may lead to new opportunities for clinical intervention in the prevention and early treatment of OA.

  18. Intrinsic constraint of unlinked total elbow replacements--the ulnotrochlear joint.

    Science.gov (United States)

    Kamineni, S; O'Driscoll, S W; Urban, M; Garg, A; Berglund, L J; Morrey, B F; An, K N

    2005-09-01

    Many unlinked total elbow replacement designs with radically differing articular geometries exist, suggesting that there is no consensus regarding an optimal design. A feature inherent to the articular design is the intrinsic constraint afforded to the joint by the implant. Our aim was to compare the intrinsic constraints of unlinked implants with that of the normal ulnotrochlear joint. We tested twelve cadaveric ulnotrochlear joints with a custom-made multiple-axis materials testing machine. With compressive loads ranging from 10 to 100 N, the joints were moved in either valgus or varus directions at 90 degrees of flexion. The ulnotrochlear components from a single example of five medium-sized unlinked elbow replacements (Ewald, Kudo, Pritchard ERS, Sorbie-Questor, and Souter-Strathclyde) were also tested. The recorded measurements included the torques and forces, angular displacement, and axial displacement of the humerus relative to the ulna. In general, the peak torque and the constraint ratio significantly increased with increasing compressive load for the implants as well as for the normal elbow. In valgus displacement, the Souter-Strathclyde implant had the highest and the Sorbie-Questor had the smallest peak torque and the Souter-Strathclyde had the highest and the Ewald had the smallest constraint ratio. In varus displacement, the Kudo had the highest and the Ewald had the smallest peak torque and constraint ratio. The constraint ratio is a characteristic that is useful for describing elbow joint behavior and for comparing the behavior of implants with that of the human elbow. Of the unlinked implants tested, the Souter-Strathclyde and Kudo prostheses most closely approximated the behavior of the human elbow joint. Implants that resemble the human elbow in appearance do not replicate normal behavior consistently, whereas other implants that do not resemble the human elbow closely do not deviate markedly from human behavior. Thus, much basic information

  19. Joint inversion of hydraulic head and self-potential data associated with harmonic pumping tests

    Science.gov (United States)

    Soueid Ahmed, A.; Jardani, A.; Revil, A.; Dupont, J. P.

    2016-09-01

    Harmonic pumping tests consist in stimulating an aquifer by the means of hydraulic stimulations at some discrete frequencies. The inverse problem consisting in retrieving the hydraulic properties is inherently ill posed and is usually underdetermined when considering the number of well head data available in field conditions. To better constrain this inverse problem, we add self-potential data recorded at the ground surface to the head data. The self-potential method is a passive geophysical method. Its signals are generated by the groundwater flow through an electrokinetic coupling. We showed using a 3-D saturated unconfined synthetic aquifer that the self-potential method significantly improves the results of the harmonic hydraulic tomography. The hydroelectric forward problem is obtained by solving first the Richards equation, describing the groundwater flow, and then using the result in an electrical Poisson equation describing the self-potential problem. The joint inversion problem is solved using a reduction model based on the principal component geostatistical approach. In this method, the large prior covariance matrix is truncated and replaced by its low-rank approximation, allowing thus for notable computational time and storage savings. Three test cases are studied, to assess the validity of our approach. In the first test, we show that when the number of harmonic stimulations is low, combining the harmonic hydraulic and self-potential data does not improve the inversion results. In the second test where enough harmonic stimulations are performed, a significant improvement of the hydraulic parameters is observed. In the last synthetic test, we show that the electrical conductivity field required to invert the self-potential data can be determined with enough accuracy using an electrical resistivity tomography survey using the same electrodes configuration as used for the self-potential investigation.

  20. International joint ventures

    DEFF Research Database (Denmark)

    Sørensen, Karsten Engsig

    2001-01-01

    The article analysis problems connected with corporate joint ventures. Among others the possible conflicts between the joint venture agreement and the statutes of the companies is examined, as well as certain problems connected to the fact that the joint venture partners have created commen control...... over their joint company....

  1. Pre- and postirradiation properties of brazed joints of AISI 316L stainless steel

    International Nuclear Information System (INIS)

    Brossa, M.; Franconi, E.; Guerreschi, U.; Pierazzi, L.; Poggi, P.; Rustia, V.

    1994-01-01

    An extensive test campaign has been performed to verify the reliability and the endurance of brazed joints between AISI 316L parts for structural applications in the nuclear field. The tests, conducted for comparison with three different high melting temperature alloys, included tensile tests (normal and shear), fatigue tests (fatigue crack propagation, low cycle fatigue, 4-point bending fatigue) and impact tests; besides, tensile tests have been performed with both unirradiated and irradiated specimens. Generally, the tests demonstrated satisfactory mechanical properties of the joints and revealed occasionally strong differences in the behaviour of the different brazing alloys, thus providing important design indications. ((orig.))

  2. Dynamic Postural-Stability Deficits After Cryotherapy to the Ankle Joint.

    Science.gov (United States)

    Fullam, Karl; Caulfield, Brian; Coughlan, Garrett F; McGroarty, Mark; Delahunt, Eamonn

    2015-09-01

    Decreased postural stability is a primary risk factor for lower limb musculoskeletal injuries. During athletic competitions, cryotherapy may be applied during short breaks in play or during half-time; however, its effects on postural stability remain unclear. To investigate the acute effects of a 15-minute ankle-joint cryotherapy application on dynamic postural stability. Controlled laboratory study. University biomechanics laboratory. A total of 29 elite-level collegiate male field-sport athletes (age = 20.8 ± 1.12 years, height = 1.80 ± 0.06 m, mass = 81.89 ± 8.59 kg) participated. Participants were tested on the anterior (ANT), posterolateral (PL), and posteromedial (PM) reach directions of the Star Excursion Balance Test before and after a 15-minute ankle-joint cryotherapy application. Normalized reach distances; sagittal-plane kinematics of the hip, knee, and ankle joints; and associated mean velocity of the center-of-pressure path during performance of the ANT, PL, and PM reach directions of the Star Excursion Balance Test. We observed a decrease in reach-distance scores for the ANT, PL, and PM reach directions from precryotherapy to postcryotherapy (P .05). We noted a decrease in mean velocity of the center-of-pressure path from precryotherapy to postcryotherapy (P cryotherapy to the ankle joint.

  3. Post Irradiation Mechanical Behaviour of Three EUROFER Joints

    International Nuclear Information System (INIS)

    Lucon, E.; Leenaers, A.; Vandermeulen, W.

    2006-01-01

    The post-irradiation mechanical properties of three EUROFER joints (two diffusion joints and one TIG weld) have been characterized after irradiation to 1.8 dpa at 300 degrees Celsius in the BR-2 reactor. Tensile, KLST impact and fracture toughness tests have been performed. Based on the results obtained and on the comparison with data from EUROFER base material irradiated under similar conditions, the post-irradiation mechanical behaviour of both diffusion joints (laboratory and mock-up) appears similar to that of the base material. The properties of the TIG joint are affected by the lack of a post-weld heat treatment, which causes the material from the upper part of the weld to be significantly worse than that of the lower region. Thus, specimens from the upper layer exhibit extremely pronounced hardening and embrittlement caused by irradiation. The samples extracted from the lower layer show much better resistance to neutron exposure, although their measured properties do not match those of the diffusion joints. The results presented demonstrate that diffusion joining can be a very promising technique.

  4. Electrostimulated recovery of welded joint durability: experiment and model

    International Nuclear Information System (INIS)

    Semakin, E.V.; Chirakadze, D.Z.; Tsellermaer, V.Ya.; Gromov, V.E.; Sosnin, O.V.

    1997-01-01

    The possibility to increase the durability of welded joints operating under conditions of low cycle fatigue is shown to be brought about using electric current pulses. Experimental method of recovery of operational capability is demonstrated on welded joints of tool steels R6M5 and 40Kh/ The onset of critical stage of fatigue in the welded joint was determined by ultrasonic testing. Then the specimens were treated with 20 Hz electric pulses with amplitude of 250 MA/M 2 for 100 μs. Such treatment resulted in an increase of time to fracture. The phenomenological model of the process is proposed

  5. Durability of shrink joints; Bestaendighet hos krympskarvar

    Energy Technology Data Exchange (ETDEWEB)

    Forsaeus Nilsson, Stefan; Saellberg, Sven-Erik

    2007-07-01

    About one third of all joint failures are caused by shrink seals losing adhesion, according to statistics from the Swedish District Heating Association. The present project was initiated upon request from the Authorisation Board of the Swedish District Heating Association in order to investigate the potential to enhance the quality of shrink joints. The purpose has been to provide a screening of the key properties of the joint systems currently available on the market. The aim has been to facilitate the choice of right materials and constructions to achieve the best functionality and cost effectiveness. The project has comprised a compilation of the views from industry representatives from manufacturers of shrink and sealing materials, pipe producers, joint contractors and district heating companies, and an experimental study where a number of joints were evaluated with respect to tightness and strength. The following joint systems took part in the investigation: Logstor SX; Canusa SuperCase; Raychem RayJoint; Powerpipe DTK with external seal Nitto NeoCover 1150 in one end and Raychem TPSM in the other; Logstor B2S med external seal Canusa KLD in one end and Raychem TPSM in the other. The joints were installed on pipes of diameters 160 mm and 450 mm. The installation was done under cold and dirty conditions, to simulate a field like worst-case scenario. After the installation, the joints were tested with respect to tightness. Peel strength and shear strength were evaluated before and after thermal ageing in +50 deg C for 70 days. Mechanical tests and ageing followed standardised procedure in EN 12068. A study of the shrink force relaxation in crosslinked and non-crosslinked polyethylene shrink sleeves was undertaken, by shrinking them onto aluminium cylinders and storing them in room temperature for about 2000 hours. The results show that it is clearly possible to install excellent shrink joints also under difficult conditions. In addition, thermal ageing does not

  6. Dynamic testing of adhesive joints using a shock testing machine

    NARCIS (Netherlands)

    Aanhold, J.E. van; Weersink, A.F.J.; Ludolphy, J.W.L.

    1998-01-01

    A light-weight shock testing machine, designed for type approval testing of naval equipment up to 300 kg mass, has been modified into a dynamic tensile test rig. This enables to test structural details for high rate dynamic tensile loadings such as occur during underwater shock. The maximum capacity

  7. Joint Chiefs of Staff > About > The Joint Staff > Senior Enlisted Advisor

    Science.gov (United States)

    Skip to main content (Press Enter). Toggle navigation Joint Chiefs of Staff Joint Chiefs of Staff Joint Chiefs of Staff Facebook Twitter YouTube Flickr Blog Instagram Search JCS: Search Search Search JCS: Search Home Media News Photos Videos Publications About The Joint Staff Chairman Vice Chairman

  8. Nano-modified adhesive by graphene: the single lap-joint case

    Energy Technology Data Exchange (ETDEWEB)

    Silva Neto, Almir; Cruz, Diego Thadeu Lopes da; Avila, Antonio Ferreira, E-mail: aavila@netuno.lcc.ufmg.b [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Dept. de Engenharia Mecanica

    2013-11-01

    This paper addresses the performance study on, low viscosity, nano-modified adhesives by graphene. For achieving this goal, single-lap joints following ASTM D 5868-01 were manufactured and tested. X-ray diffraction, scanning electron microscopy and nanoindentation were employed for graphene based nanostructures characterization. The increase on joint strength was around 57% when compared against the control group. Furthermore, all failures for the nano-modified adhesive were cohesive failure for the carbon fibre/epoxy composites indicating that the adhesive was tested. X-ray diffractions signatures indicate formation of nano-structures with 17-19 nm diameters. Moreover, nanoindentation tests revealed a homogeneous dispersion of graphene. (author)

  9. Altered lower extremity joint mechanics occur during the star excursion balance test and single leg hop after ACL-reconstruction in a collegiate athlete.

    Science.gov (United States)

    Samaan, Michael A; Ringleb, Stacie I; Bawab, Sebastian Y; Greska, Eric K; Weinhandl, Joshua T

    2018-03-01

    The effects of ACL-reconstruction on lower extremity joint mechanics during performance of the Star Excursion Balance Test (SEBT) and Single Leg Hop (SLH) are limited. The purpose of this study was to determine if altered lower extremity mechanics occur during the SEBT and SLH after ACL-reconstruction. One female Division I collegiate athlete performed the SEBT and SLH tasks, bilaterally, both before ACL injury and 27 months after ACL-reconstruction. Maximal reach, hop distances, lower extremity joint kinematics and moments were compared between both time points. Musculoskeletal simulations were used to assess muscle force production during the SEBT and SLH at both time points. Compared to the pre-injury time point, SEBT reach distances were similar in both limbs after ACL-reconstruction except for the max anterior reach distance in the ipsilateral limb. The athlete demonstrated similar hop distances, bilaterally, after ACL-reconstruction compared to the pre-injury time point. Despite normal functional performance during the SEBT and SLH, the athlete exhibited altered lower extremity joint mechanics during both of these tasks. These results suggest that measuring the maximal reach and hop distances for these tasks, in combination with an analysis of the lower extremity joint mechanics that occur after ACL-reconstruction, may help clinicians and researchers to better understand the effects of ACL-reconstruction on the neuromuscular system during the SEBT and SLH.

  10. A joint-constraint model for human joints using signed distance-fields

    DEFF Research Database (Denmark)

    Engell-Nørregård, Morten Pol; Abel, Sarah Maria Niebe; Erleben, Kenny

    2012-01-01

    We present a local joint-constraint model for a single joint which is based on distance fields. Our model is fast, general, and well suited for modeling human joints. In this work, we take a geometric approach and model the geometry of the boundary of the feasible region, i.e., the boundary of all...... allowed poses. A region of feasible poses can be built by embedding motion captured data points in a signed distance field. The only assumption is that the feasible poses form a single connected set of angular values. We show how signed distance fields can be used to generate fast and general joint......-joint dependencies, or joints with more than three degrees of freedom. The resolution of the joint-constraints can be tweaked individually for each degree of freedom, which can be used to optimize memory usage. We perform a comparative study of the key-properties of various joint-constraint models, as well...

  11. Impact damage response of natural stitched single lap-joint in composite structures

    International Nuclear Information System (INIS)

    Ghasemnejad, H.; Argentiero, Y.; Tez, T.A.; Barrington, P.E.

    2013-01-01

    Highlights: • To study the impact resistance of single lap-joints in composite structures. • To improve the impact resistance of stitched single lap joints using natural Flax yarn. • To investigate the effect of stitching on the damage process of composite materials. • To develop FE techniques to model the impact process of composite structures using LSDYNA. - Abstract: In this paper the damage behaviour of natural stitched composite single lap-joints are investigated under low velocity impact loading conditions. For this study, the laminated hybrid composite beams were pinned using Flax yarns before curing process. The Charpy impact test was chosen to study the energy absorbing capability of single lap composite joints. Composite beams were fabricated from combination of glass/epoxy and carbon/epoxy composites. It was shown that composite beams which are stitched through the thickness are able to absorb more energy in comparison with adhesive bonded composite joints in the hybrid composite beams. The Charpy impact test of stitched composite single lap joint was also simulated by finite element analysis using software LS-DYNA and the results verified with relevant experimental data

  12. Mobility function of a prosthetic knee joint with an automatic stance phase lock.

    Science.gov (United States)

    Andrysek, Jan; Klejman, Susan; Torres-Moreno, Ricardo; Heim, Winfried; Steinnagel, Bryan; Glasford, Shane

    2011-06-01

    There is a need for a prosthetic knee joint design that is technologically and functionally appropriate for use in developing countries. To develop and clinically evaluate a new type of stance phase controlled prosthetic knee joint that provides stance phase stability without inhibiting swing phase flexion. A crossover repeated measures study design comparing the new knee joint to the participant's conventional low- or high-end prosthetic knee joint. The new knee joint was fitted to fourteen individuals aged 15 to 67 years with unilateral lower limb amputations. Walk tests were performed to measure walking speed. Energy expenditure was estimated using the physiological cost index (PCI). Walking speeds with the new knee joint were on average 0.14 m/s faster than conventional low-end knees (p < 0.0001), but 0.07 m/s slower than conventional high-end prosthetic knees (p = 0.008). The PCI was similar across all three knee joint technologies (p = 0.276). Mobility function with the new knee joint, in terms of walking speed, was more closely matched to high-end than low-end prosthetic knee joints. Therefore, given its relatively simple design, the new stance phase control mechanism may offer a functional and cost effective solution for active transfemoral amputees. This paper describes a new type of prosthetic knee joint mechanism that is intended to be cost-effective while providing high-level stance phase function to active individuals with a transfemoral amputation. Initial clinical testing suggests that the new knee joint may have some functional advantages over existing technologies in this category.

  13. Estimation of Joint types and Joint Limits from Motion capture data

    DEFF Research Database (Denmark)

    Engell-Nørregård, Morten Pol; Erleben, Kenny

    2009-01-01

    It is time-consuming for an animator to explicitly model joint types and joint limits of articulated figures. In this paper we describe a simple and fast approach to automated joint estimation from motion capture data of articulated figures. Our method will make the joint modeling more efficient ...

  14. Adhesive properties and adhesive joints strength of graphite/epoxy composites

    Science.gov (United States)

    Rudawska, Anna; Stančeková, Dana; Cubonova, Nadezda; Vitenko, Tetiana; Müller, Miroslav; Valášek, Petr

    2017-05-01

    The article presents the results of experimental research of the adhesive joints strength of graphite/epoxy composites and the results of the surface free energy of the composite surfaces. Two types of graphite/epoxy composites with different thickness were tested which are used to aircraft structure. The single-lap adhesive joints of epoxy composites were considered. Adhesive properties were described by surface free energy. Owens-Wendt method was used to determine surface free energy. The epoxy two-component adhesive was used to preparing the adhesive joints. Zwick/Roell 100 strength device were used to determination the shear strength of adhesive joints of epoxy composites. The strength test results showed that the highest value was obtained for adhesive joints of graphite-epoxy composite of smaller material thickness (0.48 mm). Statistical analysis of the results obtained, the study showed statistically significant differences between the values of the strength of the confidence level of 0.95. The statistical analysis of the results also showed that there are no statistical significant differences in average values of surface free energy (0.95 confidence level). It was noted that in each of the results the dispersion component of surface free energy was much greater than polar component of surface free energy.

  15. Optimized and practical electrical joints for CORC type HTS cables

    CERN Document Server

    Mulder, T; van der Laan, D C; Mentink, M G T; Dhallé, M; ten Kate, H H J

    2015-01-01

    Within CERN the development of REBCO-CORC (Conductor On Round Core) type cables is pursued in view of possible application in future detector and accelerator magnets. An important issue is the design and qualification of terminations for connecting CORC cables mutually or to bus-bars. A termination design is envisaged that combines a simple manufacturing process with a lowest possible joint terminal resistance in the few nΩ range at 4.2 K, first for a single CORC cable and subsequently for CORC based Cable-in-Conduit Conductors. The investigation concerns the effect of tapering the CORC cable within the joint to form a staircase like geometry, which allows current to pass more directly from the copper joint casing to the inner REBCO layers of the CORC cable. Simulations have shown a substantial decrease in joint resistance at operating current in the case both CORC cable and joint casing are tapered. The CORC cable and new joint were tested at CERN. In this paper, some details of the new joint design, fabric...

  16. Optimized and practical electrical joints for CORC type HTS cables

    International Nuclear Information System (INIS)

    Mulder, T; Dudarev, A; Mentink, M G T; Ten Kate, H H J; Van der Laan, D C; Dhallé, M

    2015-01-01

    Within CERN the development of REBCO-CORC (Conductor On Round Core) type cables is pursued in view of possible application in future detector and accelerator magnets. An important issue is the design and qualification of terminations for connecting CORC cables mutually or to bus-bars. A termination design is envisaged that combines a simple manufacturing process with a lowest possible joint terminal resistance in the few nΩ range at 4.2 K, first for a single CORC cable and subsequently for CORC based Cable-in-Conduit Conductors. The investigation concerns the effect of tapering the CORC cable within the joint to form a staircase like geometry, which allows current to pass more directly from the copper joint casing to the inner REBCO layers of the CORC cable. Simulations have shown a substantial decrease in joint resistance at operating current in the case both CORC cable and joint casing are tapered. The CORC cable and new joint were tested at CERN. In this paper, some details of the new joint design, fabrication process, and model are presented and the results are summarized. (paper)

  17. The transitional vertebra and sacroiliac joint dysfunction association.

    Science.gov (United States)

    Illeez, Ozge Gulsum; Atıcı, Arzu; Ulger, Esra Bahadır; Kulcu, Duygu Geler; Ozkan, Feyza Unlu; Aktas, Ilknur

    2018-01-01

    The purpose of this study was to investigate whether transitional vertebrae contribute to the development of sacroiliac joint dysfunction. The prevalence of transitional vertebrae in patients with lumbar pain was determined during this process, and the prevalence of sacroiliac dysfunction was compared between patients with low back pain and healthy volunteers. 700 subjects, 500 with low back pain and 200 healthy volunteers were included in this study. Five tests were applied to all participants to determine sacroiliac joint dysfunction. Positivity in three tests was regarded as dysfunction. Lateral lumbosacral and Ferguson angle X-rays were taken from the group with low back pain. The patient was evaluated a specialist radiologist in terms of presence or absence of transitional vertebrae, and if identified, what type. Transitional vertebrae were determined in 26% (n = 130) of the patients with low back pain. Type 1a was determined in 20%, type 1b in 10%, type 2a in 26.9%, type 2b in 30.8%, type 3a in 0.8%, type 3b in 4.6% and type 4 in 6.9%. The prevalence of sacroiliac joint dysfunction in the low back pain group (15.4%) and the prevalence of sacroiliac joint dysfunction in cases of transitional vertebra (28.5%) were significantly higher compared to the control groups (p Sacroiliac joint dysfunction must be considered when investigating the etiology of low back pain. Particular sensitivity must be exhibited on this subject in patients with transitional vertebrae.

  18. Posterolateral elbow joint instability

    DEFF Research Database (Denmark)

    Olsen, Bo Sanderhoff; Søjbjerg, Jens Ole; Nielsen, K K

    1998-01-01

    Thirty-five osteoligamentous elbows were included in a study on the kinematics of posterolateral elbow joint instability during the pivot shift test (PST) before and after separate ligament cuttings in the lateral collateral ligament complex (LCLC). Division of the annular ligament or the lateral...... ulnar collateral ligament caused no laxity during the PST. Division of the lateral collateral ligament caused maximal laxity of 4 degrees and 23 degrees during forced PST in valgus and external rotation (supination), respectively. Cutting of the LCLC at the ulnar or the humeral insertion was necessary...... for any PST stressed elbow joint laxity to occur. Total division of the LCLC induced a maximal laxity of 7.9 degrees and 37 degrees during forced PST in valgus and external rotation (supination), respectively. This study suggests the lateral collateral ligament to be the primary soft tissue constraint...

  19. Tracking a Subset of Skeleton Joints: An Effective Approach towards Complex Human Activity Recognition

    Directory of Open Access Journals (Sweden)

    Muhammad Latif Anjum

    2017-01-01

    Full Text Available We present a robust algorithm for complex human activity recognition for natural human-robot interaction. The algorithm is based on tracking the position of selected joints in human skeleton. For any given activity, only a few skeleton joints are involved in performing the activity, so a subset of joints contributing the most towards the activity is selected. Our approach of tracking a subset of skeleton joints (instead of tracking the whole skeleton is computationally efficient and provides better recognition accuracy. We have developed both manual and automatic approaches for the selection of these joints. The position of the selected joints is tracked for the duration of the activity and is used to construct feature vectors for each activity. Once the feature vectors have been constructed, we use a Support Vector Machines (SVM multiclass classifier for training and testing the algorithm. The algorithm has been tested on a purposely built dataset of depth videos recorded using Kinect camera. The dataset consists of 250 videos of 10 different activities being performed by different users. Experimental results show classification accuracy of 83% when tracking all skeleton joints, 95% when using manual selection of subset joints, and 89% when using automatic selection of subset joints.

  20. Verification of Strength of the Welded Joints by using of the Aramis Video System

    Directory of Open Access Journals (Sweden)

    Pała Tadeusz

    2017-03-01

    Full Text Available In the paper are presented the results of strength analysis for the two types of the welded joints made according to conventional and laser technologies of high-strength steel S960QC. The hardness distributions, tensile properties and fracture toughness were determined for the weld material and heat affect zone material for both types of the welded joints. Tests results shown on advantage the laser welded joints in comparison to the convention ones. Tensile properties and fracture toughness in all areas of the laser joints have a higher level than in the conventional one. The heat affect zone of the conventional welded joints is a weakness area, where the tensile properties are lower in comparison to the base material. Verification of the tensile tests, which carried out by using the Aramis video system, confirmed this assumption. The highest level of strains was observed in HAZ material and the destruction process occurred also in HAZ of the conventional welded joint.

  1. Residual stress relief in MAG welded joints of dissimilar steels

    International Nuclear Information System (INIS)

    Seodek, P.; Brozda, J.; Wang, L.; Withers, P.J.

    2003-01-01

    This paper addresses the relief of residual stress in welded joints between austenitic and non-alloyed ferritic-pearlitic steels. A series of similar and dissimilar steel joints based on the 18G2A (ferritic-pearlitic) and 1H18N10T (austenitic) steels were produced, some of which were stress relieved by annealing and some by mechanical prestressing. For the as-welded and stress relieved test joints the residual stresses were measured by trepanning. To aid the interpretation of these results, 2D plane stress finite element analysis has been performed to simulate the residual stress relieving methods. Analysis of the results has shown that thermal stress relieving of welded joints between dissimilar steels is not effective and may even increase residual stresses, due to the considerable difference in thermal expansion of the joined steels. It was found that, for the loads imposed, the effectiveness of the mechanical stress relieving of dissimilar steel welded joints was much lower than that of similar steel joints

  2. Development of design and analysis methodology for composite bolted joints

    Science.gov (United States)

    Grant, Peter; Sawicki, Adam

    1991-05-01

    This paper summarizes work performed to develop composite joint design methodology for use on rotorcraft primary structure, determine joint characteristics which affect joint bearing and bypass strength, and develop analytical methods for predicting the effects of such characteristics in structural joints. Experimental results have shown that bearing-bypass interaction allowables cannot be defined using a single continuous function due to variance of failure modes for different bearing-bypass ratios. Hole wear effects can be significant at moderate stress levels and should be considered in the development of bearing allowables. A computer program has been developed and has successfully predicted bearing-bypass interaction effects for the (0/+/-45/90) family of laminates using filled hole and unnotched test data.

  3. Bridge joint fabrication and validation for SST-1 PF coil winding pack

    International Nuclear Information System (INIS)

    Prasad, Upendra; Sharma, A.N.; Patel, D.; Doshi, K.; Varmora, P.; Khristi, Y.; Pradhan, S.

    2014-01-01

    Highlights: • Prototype of bridge type joints fabricated and validated successfully. • Bridge type joints fabricated and validated on one of the SST-1 PF#3T coil successfully. • Joint resistance was measured with precision nano volt meter and PXI based data acquisition system. • Leak tightness of joint box was better than 3 × 10 −6 Pa m 3 s −1 . • The measured joint resistance of bridge type joint was ∼1.6 nano ohm. - Abstract: A novel concept of bridge joint for Poloidal field (PF) magnet of SST-1 with damaged winding pack has been realized. This joint has been fabricated on 5th and 6th layers of PF#3T coil winding pack (WP) after validation at 10 kA at liquid helium temperature of 4.2 K in current lead test chamber. The joint resistance of bridge joint was measured ∼1.6 nΩ at flat top DC current of 10 kA. This type of joint could be economically useful for revival of a shorted and damaged WP superconducting PF magnets of Tokamaks. In this paper, details of bridge joint design, fabrication and validations are discussed

  4. Durability of building joint sealants

    Science.gov (United States)

    Christopher C. White; Kar Tean Tan; Donald L. Hunston; R. Sam Williams

    2009-01-01

    Predicting the service life of building joint sealants exposed to service environments in less than real time has been a need of the sealant community for many decades. Despite extensive research efforts to design laboratory accelerated tests to duplicate the failure modes occurring in field exposures, little success has been achieved using conventional durability...

  5. Flanged joints with contact outside the bolt circle: ASME Part B design rules

    International Nuclear Information System (INIS)

    Rodabaugh, E.C.; Moore, S.E.

    1976-05-01

    The ASME Boiler and Pressure Vessel Code, Section VIII, Division 1, gives rules which are subdivided into ''Part A'' and ''Part B''. Part A covers flanged joints where contact between flanges occurs through a gasket located inside the bolt holes. Part B covers flanged joints with contact outside the bolt holes. This report (a) summarizes the theory for Part B flanged joints, (b) presents examples which show the significant differences between Part A flanged joints and Part B flanged joints, (c) presents the available test data relevant to the characteristics of Part B flanged joints, (d) gives listings of two computer programs which can be used to evaluate the characteristics of Part B flanged joints, and (e) gives recommendations for Code revisions and other aspects of Part B flanged-joint design

  6. Thermomechanical characterization of joints for blanket and divertor application processed by electrochemical plating

    Energy Technology Data Exchange (ETDEWEB)

    Krauss, Wolfgang; Lorenz, Julia; Konys, Jürgen; Basuki, Widodo; Aktaa, Jarir

    2016-11-01

    Highlights: • Electroplating is a relevant technology for brazing of blanket and divertor parts. • Tungsten, Eurofer and steel joints successfully fabricated. • Reactive interlayers improve adherence and reduce failure risks. • Qualification of joints performed by thermo-mechanical testing and aging. • Shear strength of joints comparable with conventionally brazing of steels. - Abstract: Fusion technology requires in the fields of first wall and divertor development reliable and adjusted joining processes of plasma facing tungsten to heat sinks or blanket structures. The components to be bonded will be fabricated from tungsten, steel or other alloys like copper. The parts have to be joined under functional and structural aspects considering the metallurgical interactions of alloys to be assembled and the filler materials. Application of conventional brazing showed lacks ranging from bad wetting of tungsten up to embrittlement of fillers and brazing zones. Thus, the deposition of reactive interlayers and filler components, e.g. Ni, Pd or Cu was initiated to overcome these metallurgical restrictions and to fabricate joints with aligned mechanical behavior. This paper presents results concerning the joining of tungsten, Eurofer and stainless steel for blanket and divertor application by applying electroplating technology. Metallurgical and mechanical characterization by shear testing were performed to analyze the joints quality and application limits in dependence on testing temperature between room temperature and 873 K and after thermal aging of up to 2000 h. The tested interlayers Ni and Pd enhanced wetting and enabled the processing of reliable joints with a shear strength of more than 200 MPa at RT.

  7. AGM-69A Joint Test Unit

    Science.gov (United States)

    1975-11-15

    that the JTU payload will reliably and effectively meet SAC test requirements. However, the inherent absence of a flight termination (command destruct...ubsequent post fuzing anomalies were observed at the Air Force Eastern Test Range ( AFETR ) on five of the six BULLET .BLITZ II missions. The severity of these...some effect on mission planning and trajectory positioning on the test range. With a severe tumble after fuzing, it is possible that the missile will

  8. Prosthetic hip joint infection due to Campylobacter fetus.

    OpenAIRE

    Bates, C J; Clarke, T C; Spencer, R C

    1994-01-01

    A case of postoperative prosthetic hip joint infection due to Campylobacter fetus subsp. fetus is described. Difficulties in isolation and antimicrobial susceptibility testing of this organism are discussed.

  9. The OMERACT-RAMRIS Rheumatoid Arthritis Magnetic Resonance Imaging Joint Space Narrowing Score

    DEFF Research Database (Denmark)

    Møller Døhn, Uffe; Conaghan, Philip G; Eshed, Iris

    2014-01-01

    To test the intrareader and interreader reliability of assessment of joint space narrowing (JSN) in rheumatoid arthritis (RA) wrist and metacarpophalangeal (MCP) joints on magnetic resonance imaging (MRI) and computed tomography (CT) using the newly proposed OMERACT-RAMRIS JSN scoring method...

  10. Radiographic evaluation of degenerative joint disease in horses: interpretive principles

    International Nuclear Information System (INIS)

    Widmer, W.R.; Blevins, W.E.

    1994-01-01

    Degenerative joint disease in horses is characterized by the progressive deterioration of articular cartilage of synovial joints. The morbidity associated with degenerative joint disease, particularly the loss of function in pleasure and performance horses, costs horse owners millions of dollars each year. Although new drugs, such as polysulfated glycosaminoglycans and hyaluronic acid, are available for the treatment of patients with degenerative joint disease, the success of therapy depends on early diagnosis. Diagnostic imaging strategies, therefore, should focus on accurate and timely diagnosis of degenerative joint disease to provide prompt therapy. Early identification of degenerative joint disease is also beneficial because the use and/or training methods of affected patients may be altered, possibly limiting the progression of the disease. The pathogenesis of degenerative joint disease is complex and multifactorial. Current evidence suggests that initiating factors lead to a final common pathway-breakdown of articular cartilage. There are many diagnostic tests that aid practitioners in detecting degenerative joint disease; however, the most important imaging technique is radiography. During the early stages of the disease, radiographic changes may be slight; therefore, it is essential that practitioners have adequate equipment to obtain high-quality radiographs. Thinning of the joint space, osteophytosis, enthesopathy, changes in subchondral bone, and increased synovium and synovia provide radiographic evidence of degenerative joint disease. By understanding the pathophysiology of the disease and how technical alterations affect the subtle radiographic changes, practitioners can more accurately diagnose degenerative joint disease during its early stages and institute proper therapy

  11. Removal Torque and Biofilm Accumulation at Two Dental Implant-Abutment Joints After Fatigue.

    Science.gov (United States)

    Pereira, Jorge; Morsch, Carolina S; Henriques, Bruno; Nascimento, Rubens M; Benfatti, Cesar Am; Silva, Filipe S; López-López, José; Souza, Júlio Cm

    2016-01-01

    The aim of this study was to evaluate the removal torque and in vitro biofilm penetration at Morse taper and hexagonal implant-abutment joints after fatigue tests. Sixty dental implants were divided into two groups: (1) Morse taper and (2) external hexagon implant-abutment systems. Fatigue tests on the implant-abutment assemblies were performed at a normal force (FN) of 50 N at 1.2 Hz for 500,000 cycles in growth medium containing human saliva for 72 hours. Removal torque mean values (n = 10) were measured after fatigue tests. Abutments were then immersed in 1% protease solution in order to detach the biofilms for optical density and colony-forming unit (CFU/cm²) analyses. Groups of implant-abutment assemblies (n = 8) were cross-sectioned at 90 degrees relative to the plane of the implant-abutment joints for the microgap measurement by field-emission guns scanning electron microscopy. Mean values of removal torque on abutments were significantly lower for both Morse taper (22.1 ± 0.5 μm) and external hexagon (21.1 ± 0.7 μm) abutments after fatigue tests than those recorded without fatigue tests (respectively, 24 ± 0.5 μm and 24.8 ± 0.6 μm) in biofilm medium for 72 hours (P = .04). Mean values of microgap size for the Morse taper joints were statistically signicantly lower without fatigue tests (1.7 ± 0.4 μm) than those recorded after fatigue tests (3.2 ± 0.8 μm). Also, mean values of microgap size for external hexagon joints free of fatigue were statistically signicantly lower (1.5 ± 0.4 μm) than those recorded after fatigue tests (8.1 ± 1.7 μm) (P abutments (Abs630nm at 0.06 and 2.9 × 10⁴ CFU/cm²) than that on external hexagon abutments (Abs630nm at 0.08 and 4.5 × 10⁴ CFU/cm²) (P = .01). The mean values of removal torque, microgap size, and biofilm density recorded at Morse taper joints were lower in comparison to those recorded at external hexagon implant-abutment joints after fatigue tests in a simulated oral environment for 72 hours.

  12. Characteristics of Laser Beam and Friction Stir Welded AISI 409M Ferritic Stainless Steel Joints

    Science.gov (United States)

    Lakshminarayanan, A. K.; Balasubramanian, V.

    2012-04-01

    This article presents the comparative evaluation of microstructural features and mechanical properties of friction stir welded (solid-state) and laser beam welded (high energy density fusion welding) AISI 409M grade ferritic stainless steel joints. Optical microscopy, microhardness testing, transverse tensile, and impact tests were performed. The coarse ferrite grains in the base material were changed to fine grains consisting duplex structure of ferrite and martensite due to the rapid cooling rate and high strain induced by severe plastic deformation caused by frictional stirring. On the other hand, columnar dendritic grain structure was observed in fusion zone of laser beam welded joints. Tensile testing indicates overmatching of the weld metal relative to the base metal irrespective of the welding processes used. The LBW joint exhibited superior impact toughness compared to the FSW joint.

  13. Immediate effects of neuromuscular joint facilitation intervention after anterior cruciate ligament reconstruction.

    Science.gov (United States)

    Wang, Lei

    2016-07-01

    [Purpose] The aim of this study was to examine the immediate effects of neuromuscular joint facilitation (NJF) on the functional activity level after rehabilitation of anterior cruciate ligament (ACL) reconstruction. [Subjects and Methods] Ten young subjects (8 males and 2 females) who underwent ACL reconstruction were included in the study. The subjects were divided into two groups, namely, knee joint extension muscle strength training (MST) group and knee joint extension outside rotation pattern of NJF group. Extension strength was measured in both groups before and after the experiment. Surface electromyography (sEMG) of the vastus medialis and vastus lateralis muscles and joint position error (JPE) test of the knee joint were also conducted. [Results] JPE test results and extension strength measurements in the NJF group were improved compared with those in the MST group. Moreover, the average discharge of the vastus medialis and vastus lateralis muscles on sEMG in the NJF group was significantly increased after MST and NJF treatments. [Conclusion] The obtained results suggest that NJF training in patients with ACL reconstruction can improve knee proprioception ability and muscle strength.

  14. The effect of brazing parameters on corrosion behavior of brazed aluminum joints

    Science.gov (United States)

    Ghasimakbari, Farzam; Hadian, Ali Mohammad; Ershadrad, Soheil; Omidazad, Amir Mansour

    2018-01-01

    Fluid transmission pipes made of aluminum are widely used in petrochemical industries. For many applications, they have to be brazed to each other. The brazed joints, in many cases, are encountered with corrosive medias. This paper reports a part of a work to investigate the corrosion behavior of brazed AA6061 using AA4047 as filler metal with and without the use of flux under different brazing atmospheres. The samples brazed under air, vacuum, argon, and hydrogen atmospheres. The interfacial area of the joints was examined to ensure being free of any defects. The sides of each test piece were covered with an insulator and the surface of the joint was encountered to polarization test. The results revealed a significant difference of corrosion resistance. The samples that brazed under argon and hydrogen atmospheres had better corrosion resistance than other samples. The microstructure of the corroded joints revealed that the presence of defects, impurities due to use of flux and depth of filter metal penetration in base metal are crucial variables on the corrosion resistance of the joints.

  15. Flat H Frangible Joint Evolution

    Science.gov (United States)

    Diegelman, Thomas E.; Hinkel, Todd J.; Benjamin, Andrew; Rochon, Brian V.; Brown, Christopher W.

    2016-01-01

    Space vehicle staging and separation events require pyrotechnic devices. They are single-use mechanisms that cannot be tested, nor can failure-tolerant performance be demonstrated in actual flight articles prior to flight use. This necessitates the implementation of a robust design and test approach coupled with a fully redundant, failure-tolerant explosive mechanism to ensure that the system functions even in the event of a single failure. Historically, NASA has followed the single failure-tolerant (SFT) design philosophy for all human-rated spacecraft, including the Space Shuttle Program. Following the end of this program, aerospace companies proposed building the next generation human-rated vehicles with off-the-shelf, non-redundant, zero-failure-tolerant (ZFT) separation systems. Currently, spacecraft and launch vehicle providers for both the Orion and Commercial Crew Programs (CCPs) plan to deviate from the heritage safety approach and NASA's SFT human rating requirements. Both programs' partners have base-lined ZFT frangible joints for vehicle staging and fairing separation. These joints are commercially available from pyrotechnic vendors. Non-human-rated missions have flown them numerous times. The joints are relatively easy to integrate structurally within the spacecraft. In addition, the separation event is debris free, and the resultant pyro shock is lower than that of other design solutions. It is, however, a serious deficiency to lack failure tolerance. When used for critical applications on human-rated vehicles, a single failure could potentially lead to loss of crew (LOC) or loss of mission (LOM)). The Engineering and Safety & Mission Assurance directorates within the NASA Johnson Space Center took action to address this safety issue by initiating a project to develop a fully redundant, SFT frangible joint design, known as the Flat H. Critical to the ability to retrofit on launch vehicles being developed, the SFT mechanisms must fit within the same

  16. Disability in patients with trapeziometacarpal joint arthrosis: incidental versus presenting diagnosis.

    Science.gov (United States)

    Becker, Stéphanie J E; Makarawung, Dennis J S; Spit, Silke A; King, John D; Ring, David

    2014-10-01

    To test the hypothesis that there is no difference in trapeziometacarpal (TMC) joint arthrosis-related symptoms and disability between patients seeking treatment for symptoms of TMC arthrosis and those with incidental TMC joint arthrosis. We compared 64 patients presenting for care of TMC joint arthrosis with 64 with incidental TMC joint arthrosis. For both groups, the diagnosis was based on crepitation on examination. Bivariate and multivariate analyses assessed factors associated with symptoms and disability related to TMC joint arthrosis. In bivariate analysis, patients presenting for care of TMC joint arthrosis had significantly more symptoms and disability from TMC joint arthrosis than those with incidental TMC joint arthrosis. The best multivariate linear regression model for fewer TMC joint arthrosis-related symptoms and disability included patients with incidental TMC joint arthrosis, male sex, no other painful conditions, less catastrophic thinking, and fewer depressive symptoms and explained 74% of the variability. Having incidental TMC joint arthrosis (25%) and more adaptive coping strategies (less catastrophic thinking; 5%) were the most important contributors to fewer symptoms and less disability. Future studies are merited to determine whether training in better coping strategies (eg, less catastrophic thinking and fewer depressive symptoms) can decrease symptoms and disability in patients with TMC joint arthrosis. Prognostic III. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  17. Mechanical Properties and Microstructure of Dissimilar Material Welded Joints

    Directory of Open Access Journals (Sweden)

    Ziewiec A.

    2014-10-01

    Full Text Available The paper presents results of the mechanical testing and the microstructure analysis of dissimilar welded joint of the R350HT steel and the high-manganese (Hadfield cast steel using Cr-Ni cast steel spacer. The simulation tests of the welded joint surface deformation were carried out. The macroscopic and microscopic investigation were made using light microscopy (LM and scanning electron microscopy (SEM. Content of the magnetic phase was measured using magnetoscope. The quantitative metallographic investigation was used for assessment of ferrite and martensite contents and X-ray diffraction phase analysis was carried out. The results showed that during cooling of the spacer after welding, the transformation of metastable austenite into martensite proceeded. In addition to work hardening, the phase transformation of austenite into martensite occurs during the process of the superficial deformation of the spacer while simulated exploitation. This leads to a substantial increase of hardness, and at the same time, causes the increase of wear resistance of the welded joints of crossovers.

  18. Ti–6Al–4V welded joints via electron beam welding: Microstructure, fatigue properties, and fracture behavior

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Xiaoguang [School of Energy and Power Engineering, Beihang University, Beijing 100191 (China); Co-Innovation Center for Advanced Aero-Engine, Beijing 100191 (China); Li, Shaolin [School of Energy and Power Engineering, Beihang University, Beijing 100191 (China); Qi, Hongyu, E-mail: qhy@buaa.edu.cn [School of Energy and Power Engineering, Beihang University, Beijing 100191 (China); Co-Innovation Center for Advanced Aero-Engine, Beijing 100191 (China)

    2014-03-01

    The effect of microstructural characteristics on the fatigue properties of electron beam-welded joints of forged Ti–6Al–4V and its fracture behavior were investigated. Tensile tests and fatigue tests were conducted at room temperature in air atmosphere. The test data were analyzed in relation to microstructure, high-cycle fatigue properties, low-cycle fatigue properties, and fatigue crack propagation properties. The high-cycle fatigue test results indicated that the fatigue strength of the joint welded via electron beam welding was higher than that of the base metal because the former had a high yield strength and all high-cycle fatigue specimens were fractured in the base metal. Although the joint specimens had a lower low-cycle fatigue life than the base metal, they mainly ruptured at the fusion zone of the joint specimen and their crack initiation mechanism is load-dependent. The fatigue crack propagation test results show that the joint had a slower crack propagation rate than the base metal, which can be attributed to the larger grain in the fusion zone.

  19. Technical feasibility of personalized articulating knee joint distraction for treatment of tibiofemoral osteoarthritis.

    Science.gov (United States)

    Struik, T; Jaspers, J E N; Besselink, N J; van Roermund, P M; Plomp, S; Rudert, M J; Lafeber, F P J G; Mastbergen, S C

    2017-11-01

    Knee osteoarthritis is a highly prevalent degenerative joint disorder characterized by joint tissue damage and pain. Knee joint distraction has been introduced as a joint preserving surgical procedure to postpone knee arthroplasty. An often used standard externally fixation device for distraction poses a burden to patients due to the absence of joint flexion during the 6weeks treatment. Therefore, a personalized articulating distraction device was developed. The aim of this study was to test technical feasibility of this device. Based on an often applied rigid device, using equal bone pin positions and connectors, a hinge mechanism was developed consisting of a cam-following system for reproducing the complex joint-specific knee kinematics. In support, a device was developed for capturing the joint-specific sagittal plane articulation. The obtained kinematic data were translated into joint-specific cam shapes that were installed bilaterally in the hinge mechanism of the distraction device, as such providing personalized knee motion. Distraction of 5mm was performed within a range of motion of 30deg. joint flexion. Pre-clinical evaluation of the working principle was performed on human cadaveric legs and system stiffness characteristics were biomechanically evaluated. The desired range of motion was obtained and distraction was maintained under physiologically representative loading. Moreover, the joint-specific approach demonstrated tolerance of deviations from anatomical and alignment origin during initial placement of the developed distraction device. Articulation during knee distraction is considered technically feasible and has potential to decrease burden and improve acceptance of distraction therapy. Testing of clinical feasibility is warranted. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Influence of step length and landing pattern on patellofemoral joint kinetics during running.

    Science.gov (United States)

    Willson, J D; Ratcliff, O M; Meardon, S A; Willy, R W

    2015-12-01

    Elevated patellofemoral joint kinetics during running may contribute to patellofemoral joint symptoms. The purpose of this study was to test for independent effects of foot strike pattern and step length on patellofemoral joint kinetics while running. Effects were tested relative to individual steps and also taking into account the number of steps required to run a kilometer with each step length. Patellofemoral joint reaction force and stress were estimated in 20 participants running at their preferred speed. Participants ran using a forefoot strike and rearfoot strike pattern during three different step length conditions: preferred step length, long (+10%) step length, and short (-10%) step length. Patellofemoral kinetics was estimated using a biomechanical model of the patellofemoral joint that accounted for cocontraction of the knee flexors and extensors. We observed independent effects of foot strike pattern and step length. Patellofemoral joint kinetics per step was 10-13% less during forefoot strike conditions and 15-20% less with a shortened step length. Patellofemoral joint kinetics per kilometer decreased 12-13% using a forefoot strike pattern and 9-12% with a shortened step length. To the extent that patellofemoral joint kinetics contribute to symptoms among runners, these running modifications may be advisable for runners with patellofemoral pain. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Influence of Connection Placement to the Behavior of Precast Concrete Exterior Beam-Column Joint

    Directory of Open Access Journals (Sweden)

    Elly Tjahjono

    2010-10-01

    Full Text Available This paper presents an experimental study on the influence of connection placement to the behaviour of exterior beamcolumn joint of precast concrete structure under semi cyclic loading. Four half-scale beam-column specimens were investigated. Three beam-columns were jointed through connection that are placed in beam-column joint region and the forth is connected at the plastic hinge potensial region of the beam. Crack patterns, strength, stiffness and ductility of the test specimens have been evaluated. The test result indicated that all beam-column specimens show good ductility behavior.

  2. Joint multifractal analysis based on wavelet leaders

    Science.gov (United States)

    Jiang, Zhi-Qiang; Yang, Yan-Hong; Wang, Gang-Jin; Zhou, Wei-Xing

    2017-12-01

    Mutually interacting components form complex systems and these components usually have long-range cross-correlated outputs. Using wavelet leaders, we propose a method for characterizing the joint multifractal nature of these long-range cross correlations; we call this method joint multifractal analysis based on wavelet leaders (MF-X-WL). We test the validity of the MF-X-WL method by performing extensive numerical experiments on dual binomial measures with multifractal cross correlations and bivariate fractional Brownian motions (bFBMs) with monofractal cross correlations. Both experiments indicate that MF-X-WL is capable of detecting cross correlations in synthetic data with acceptable estimating errors. We also apply the MF-X-WL method to pairs of series from financial markets (returns and volatilities) and online worlds (online numbers of different genders and different societies) and determine intriguing joint multifractal behavior.

  3. Prosthetic joint infection: state-of-the-art

    Directory of Open Access Journals (Sweden)

    Boris Sergeyevich Belov

    2013-01-01

    Full Text Available In current clinical practice, joint replacement is one of the progressive and permanently developed surgical treatments in patients with locomotor injury of any genesis. However, the upward trend in the number of replacements is inevitably accompanied by the rising number of patients with periprosthetic joint infection. The polymorphism of its clinical picture and the nonspecificity of diagnostic tests lead to a frequent delay in the diagnosis of prosthetic joint infection (PJI and thus late treatment. This paper gives an update on the etiology, epidemiology, clinical presentation, and diagnosis of PJI. Emphasis is laid on the value of a multimodal approach to PJI treatment Р a combination of surgery and etiotropic antibiotic therapy. The choice of a treatment modality is determined by patient status, comorbidity, and the magnitude and duration of the infectious process.

  4. Creep simulation of adhesively bonded joints using modified generalized time hardening model

    Energy Technology Data Exchange (ETDEWEB)

    Sadigh, Mohammad Ali Saeimi [Azarbaijan Shahid Madani University, Tabriz (Iran, Islamic Republic of)

    2016-04-15

    Creep behavior of double lap adhesively bonded joints was investigated using experimental tests and numerical analysis. Firstly, uniaxial creep tests were carried out to obtain the creep characteristics and constitutive parameters of the adhesive at different stress and temperature levels. Generalized time hardening model was used to predict the creep behavior of the adhesive. This model was modified to simulate the creep behavior at different stress and temperature levels. Secondly, the developed model was used to simulate the creep behavior of bonded joints using finite element based numerical analysis. Creep deformations of the joints were measured experimentally and good agreement was observed in comparison with the results obtained using numerical simulation. Afterward, stress redistribution due to the creep along the adhesively bonded joint was obtained numerically. It was observed that temperature level had a significant effect on the stress redistribution along the adhesive thickness.

  5. Joint analysis of binary and quantitative traits with data sharing and outcome-dependent sampling.

    Science.gov (United States)

    Zheng, Gang; Wu, Colin O; Kwak, Minjung; Jiang, Wenhua; Joo, Jungnam; Lima, Joao A C

    2012-04-01

    We study the analysis of a joint association between a genetic marker with both binary (case-control) and quantitative (continuous) traits, where the quantitative trait values are only available for the cases due to data sharing and outcome-dependent sampling. Data sharing becomes common in genetic association studies, and the outcome-dependent sampling is the consequence of data sharing, under which a phenotype of interest is not measured for some subgroup. The trend test (or Pearson's test) and F-test are often, respectively, used to analyze the binary and quantitative traits. Because of the outcome-dependent sampling, the usual F-test can be applied using the subgroup with the observed quantitative traits. We propose a modified F-test by also incorporating the genotype frequencies of the subgroup whose traits are not observed. Further, a combination of this modified F-test and Pearson's test is proposed by Fisher's combination of their P-values as a joint analysis. Because of the correlation of the two analyses, we propose to use a Gamma (scaled chi-squared) distribution to fit the asymptotic null distribution for the joint analysis. The proposed modified F-test and the joint analysis can also be applied to test single trait association (either binary or quantitative trait). Through simulations, we identify the situations under which the proposed tests are more powerful than the existing ones. Application to a real dataset of rheumatoid arthritis is presented. © 2012 Wiley Periodicals, Inc.

  6. Strategy of arm movement control is determined by minimization of neural effort for joint coordination.

    Science.gov (United States)

    Dounskaia, Natalia; Shimansky, Yury

    2016-06-01

    Optimality criteria underlying organization of arm movements are often validated by testing their ability to adequately predict hand trajectories. However, kinematic redundancy of the arm allows production of the same hand trajectory through different joint coordination patterns. We therefore consider movement optimality at the level of joint coordination patterns. A review of studies of multi-joint movement control suggests that a 'trailing' pattern of joint control is consistently observed during which a single ('leading') joint is rotated actively and interaction torque produced by this joint is the primary contributor to the motion of the other ('trailing') joints. A tendency to use the trailing pattern whenever the kinematic redundancy is sufficient and increased utilization of this pattern during skillful movements suggests optimality of the trailing pattern. The goal of this study is to determine the cost function minimization of which predicts the trailing pattern. We show that extensive experimental testing of many known cost functions cannot successfully explain optimality of the trailing pattern. We therefore propose a novel cost function that represents neural effort for joint coordination. That effort is quantified as the cost of neural information processing required for joint coordination. We show that a tendency to reduce this 'neurocomputational' cost predicts the trailing pattern and that the theoretically developed predictions fully agree with the experimental findings on control of multi-joint movements. Implications for future research of the suggested interpretation of the trailing joint control pattern and the theory of joint coordination underlying it are discussed.

  7. Riveted Lap Joints in Aircraft Fuselage Design, Analysis and Properties

    CERN Document Server

    Skorupa, Andrzej

    2012-01-01

    Fatigue of the pressurized fuselages of transport aircraft is a significant problem all builders and users of aircraft have to cope with for reasons associated with assuring a sufficient lifetime and safety, and formulating adequate inspection procedures. These aspects are all addressed in various formal protocols for creating and maintaining airworthiness, including damage tolerance considerations. In most transport aircraft, fatigue occurs in lap joints, sometimes leading to circumstances that threaten safety in critical ways. The problem of fatigue of lap joints has been considerably enlarged by the goal of extending aircraft lifetimes. Fatigue of riveted lap joints between aluminium alloy sheets, typical of the pressurized aircraft fuselage, is the major topic of the present book. The richly illustrated and well-structured chapters treat subjects such as: structural design solutions and loading conditions for fuselage skin joints; relevance of laboratory test results for simple lap joint specimens to rive...

  8. Bio-inspired design of geometrically interlocked 3D printed joints

    Science.gov (United States)

    Kumar, S.; Oliva, Noel; Kumar's Lab Team

    The morphology of the adhesive-adherend interface significantly affects the mechanical behavior of adhesive joints. As seen in some biocomposites like human skull, or the nacre of some bivalve molluscs' shells, a geometrically interlocking architecture of interfaces creates toughening and strengthening mechanisms enhancing the mechanical properties of the joint. In an attempt to characterize this mechanical interlocking mechanism, this study is focused on computational and experimental investigation of a single-lap joint with a very simple geometrically interlocked interface design in which both adherends have a square waveform configuration of the joining surfaces. This square waveform configuration contains a positive and a negative rectangular teeth per cycle in such a way that the joint is symmetric about the mid-bondlength. Both physical tests performed on 3D printed prototypes of joints and computational results indicate that the joints with square waveform design have higher strength and damage tolerance than those of joints with flat interface. In order to identify an optimal design configuration of this interface, a systematic parametric study is conducted by varying the geometric and material properties of the non-flat interface. This work was supported by Lockheed Martin (Award No: 12NZZ1).

  9. Value of Examination Under Fluoroscopy for the Assessment of Sacroiliac Joint Dysfunction.

    Science.gov (United States)

    Eskander, Jonathan P; Ripoll, Juan G; Calixto, Frank; Beakley, Burton D; Baker, Jeffrey T; Healy, Patrick J; Gunduz, O H; Shi, Lizheng; Clodfelter, Jamie A; Liu, Jinan; Kaye, Alan D; Sharma, Sanjay

    2015-01-01

    Pain emanating from the sacroiliac (SI) joint can have variable radiation patterns. Single physical examination tests for SI joint pain are inconsistent with multiple tests increasing both sensitivity and specificity. To evaluate the use of fluoroscopy in the diagnosis of SI joint pain. Prospective double blind comparison study. Pain clinic and radiology setting in urban Veterans Administration (VA) in New Orleans, Louisiana. Twenty-two adult men, patients at a southeastern United States VA interventional pain clinic, presented with unilateral low back pain of more than 2 months' duration. Patients with previous back surgery were excluded from the study. Each patient was given a Gapping test, Patrick (FABERE) test, and Gaenslen test. A second blinded physician placed each patient prone under fluoroscopic guidance, asking each patient to point to the most painful area. Pain was provoked by applying pressure with the heel of the palm in that area to determine the point of maximum tenderness. The area was marked with a radio-opaque object and was placed on the mark with a fluoroscopic imgage. A site within 1 cm of the SI joint was considered as a positive test. This was followed by a diagnostic injection under fluoroscopy with 1 mL 2% lidocaine. A positive result was considered as more than 2 hours of greater than 75% reduction in pain. Then, in 2-3 days this was followed by a therapeutic injection under fluoroscopy with 1 mL 0.5% bupivacaine and 40 mg methylprednisolone. Each patient was reassessed after 6 weeks. The sensitivity and specificity in addition to the positive and negative predictive values were determined for both the conventional examinations, as well as the examination under fluoroscopy. Finally, a receiver operating characteristic (ROC) curve was constructed to evaluate test performance. The sensitivity and specificity of the fluoroscopic examination were 0.82 and 0.80 respectively; Positive predictive value and negative predictive value were 0.93 and

  10. A coupled mechanical-hydrological methodology for modeling flow in jointed rock masses using laboratory data for the joint flow model

    International Nuclear Information System (INIS)

    Voss, C.F.; Bastian, R.J.; Shotwell, L.R.

    1986-01-01

    Pacific Northwest Laboratory (PNL) currently supports the U.S. Department of Energy's Office of Civilian Radioactive Waste Management in developing and evaluating analytical methods for assessing the suitability of sites for geologic disposal of high-level radioactive waste. The research includes consideration of hydrological, geomechanical, geochemical, and waste package components and the evaluation of the degree of coupling that can occur between two or more of these components. The PNL effort and those of other research groups investing potential waste sites in the U.S. and abroad are producing a suite of computer codes to analyze the long-term performance of the proposed repository sites. This paper summarizes the ongoing research in rock mechanics at PNL involving flow through jointed rock. The objective of this research is to develop a methodology for modeling the coupled mechanical-hydrological process of flow through joints and then attempt to validate a ''simple'' model using small-scale laboratory test data as a basis for judging whether the approach has merit. This paper discusses the laboratory tests being conducted to develop a joint behavioral constitutive model for the numerical method under development and the modeling approach being considered

  11. COMPLEX FUNCTIONAL ASSESSMENT OF THE HIP JOINT.

    Directory of Open Access Journals (Sweden)

    Maya S. Krastanova

    2015-09-01

    Full Text Available Introduction: In relation to the study reporting the effects of applying phased complex rehabilitation in patients with total hip arthroplasty, it has been concluded that the everyday clinical practice in Bulgaria does not apply complex examination, giving an objective picture about the extent of functional status of patients with trauma and diseases of the hip. Aim: The main goal of this report is to present a test which incorporates all known and routine research and in which the total number of points determines the functional status of patients with trauma and diseases of the hip. Material and Methods: Based on the Hip dysfunction and Osteoarthritis Outcome Score, the Harris Hip Score modified test, scale D’Aubigne and Postel and Iowa’s test for complex functional evaluation of the hip joint, we have developed a test including information about the degree of pain; goniometry and manual muscle testing of the hip; locomotor test – type of gait and adjuvants; test for Daily Activities of Life. The test has been developed on the basis of expert assessment by doctors and physiotherapists of the proposed indicators for evaluation and determination of the weighting factors’ contribution to the general condition of the patient. Conclusion: The developed and tested method of complex functional assessment of the hip joint enables our colleagues, dealing with trauma and diseases of the hip, to use it in various research and scientific projects, as well as in general medical practice.

  12. Non-destructive clearance measuring in closed joints

    International Nuclear Information System (INIS)

    Doucelance, C.; Manaranche, J.C.

    1976-01-01

    Two methods for clearance measuring in closed joints are described. The first one is based on the mechanical impedance concept, while the other one requires a shock test on shaker. Both are illustrated with an example of application [fr

  13. Development of dissimilar metal transition joint by hot roll bonding technique

    International Nuclear Information System (INIS)

    Nagai, Takayuki; Takeda, Seiichiro; Tanaka, Yasumasa; Ogawa, Kazuhiro; Nakasuji, Kazuyuki; Ikenaga, Yoshiaki.

    1994-01-01

    Metallurgically bonded transition joints which enable to connect reprocessing equipments made of superior corrosion resistant valve metals (Ti-5Ta, Zr or Ti) with stainless steel piping is needed for nuclear fuel reprocessing plants. The authors have developed dissimilar metal transition joints between stainless steel and Ti-5Ta, Zr or Ti with an insert metal of Ta by the hot roll bonding process, using the newly developed mill called 'rotary reduction mill'. In the R and D program, appropriate bonding conditions in the manufacturing process of the joints were established. This report presents the structure of transition joints and the manufacturing process by the hot roll bonding technique. Then, the evaluation of mechanical and corrosion properties and the results of demonstration test of joints for practical use are described. (author)

  14. Development of dissimilar metal transition joint by hot roll bonding technique

    International Nuclear Information System (INIS)

    Nagai, Takayuki; Takeuchi, Masayuki; Takeda, Seiichiro; Shikakura, Sakae; Ogawa, Kazuhiro; Nakasuji, Kazuyuki; Kajimura, Haruhiko.

    1995-01-01

    Metallurgically bonded transition joints which enable to connect reprocessing equipments made of superior corrosion resistant valve metals (Ti-5Ta, Zr or Ti) with stainless steel piping is needed for nuclear fuel reprocessing plants. The authors have developed dissimilar metal transition joints between stainless steel and Ti-5Ta, Zr or Ti with an insert metal of Ta by the hot roll bonding process, using the newly developed mill called 'rotary reduction mill'. In the R and D program, appropriate bonding conditions in the manufacturing process of the joints were established. This report presents the structure of transition joints and the manufacturing process by hot roll bonding technique. Then, the evaluation of mechanical and corrosion properties and the results of demonstration test of joints for practical use are described. (author)

  15. The modelling and measurement of super-conducting rock joints

    International Nuclear Information System (INIS)

    Barton, N.; Makurat, A.; Vik, G.; Loset, F.

    1985-01-01

    Rock joints exhibiting exceptionally high conductivity have been responsible for severe inflows (10-50 m 3 /min.) and flooding in recent Norwegian tunneling projects. These events may be explained by channeling of flow in partially outwashed mineral fillings, associated with deep weathering in ancient basement rocks. There is also evidence to suggest extensional strain with consistent relationships to regional faulting patterns (Selmer-Olsen 1981). Hydraulic fractures making connection with joint systems that are sheared as a result of increased fluid pressure, has been deduced as the mechanism explaining unusually large fluid losses in the geothermal project in Cornwall, England (Pine and Batchelor, 1984). Such mechanisms also introduce uncertainty into water flood and MHF stimulation treatment of fractured oil and gas reservoirs, particularly when principal stress and joint orientations are poorly understood due to coring and stress measurement problems in weak, overstressed reservoir rocks. The possibility of permanent disposal of nuclear waste in crystalline rock, has also focussed attention on highly conductive (''super-conducting'') joints in nuclear waste programmes in Canada, the USA and in Europe. The bi-modal distributions of joint spacing, continuity, apertures and conductivities resulting from the discovery of super-conducting joints has important implications for the location of planned repositories, due to their dramatic impact on potential transport times. In the laboratory a class of super-conducting joints can be created by shear displacement that causes dilation when shearing non-planar features. Recent biaxial shear testing of rock joints recovered in jointed core has identified a strong coupling of conductivity and shear displacement. The theoretical predictions of constitutive relationships for coupled flow in rock joints (Barton et al. 1985) have been broadly verified

  16. Influence of the implant-abutment connection design and diameter on the screw joint stability

    Science.gov (United States)

    Shin, Hyon-Mo; Huh, Jung-Bo; Yun, Mi-Jeong; Jeon, Young-Chan; Chang, Brian Myung

    2014-01-01

    PURPOSE This study was conducted to evaluate the influence of the implant-abutment connection design and diameter on the screw joint stability. MATERIALS AND METHODS Regular and wide-diameter implant systems with three different joint connection designs: an external butt joint, a one-stage internal cone, and a two-stage internal cone were divided into seven groups (n=5, in each group). The initial removal torque values of the abutment screw were measured with a digital torque gauge. The postload removal torque values were measured after 100,000 cycles of a 150 N and a 10 Hz cyclic load had been applied. Subsequently, the rates of the initial and postload removal torque losses were calculated to evaluate the effect of the joint connection design and diameter on the screw joint stability. Each group was compared using Kruskal-Wallis test and Mann-Whitney U test as post-hoc test (α=0.05). RESULTS The postload removal torque value was high in the following order with regard to magnitude: two-stage internal cone, one-stage internal cone, and external butt joint systems. In the regular-diameter group, the external butt joint and one-stage internal cone systems showed lower postload removal torque loss rates than the two-stage internal cone system. In the wide-diameter group, the external butt joint system showed a lower loss rate than the one-stage internal cone and two-stage internal cone systems. In the two-stage internal cone system, the wide-diameter group showed a significantly lower loss rate than the regular-diameter group (P<.05). CONCLUSION The results of this study showed that the external butt joint was more advantageous than the internal cone in terms of the postload removal torque loss. For the difference in the implant diameter, a wide diameter was more advantageous in terms of the torque loss rate. PMID:24843398

  17. Influence of the implant-abutment connection design and diameter on the screw joint stability.

    Science.gov (United States)

    Shin, Hyon-Mo; Huh, Jung-Bo; Yun, Mi-Jeong; Jeon, Young-Chan; Chang, Brian Myung; Jeong, Chang-Mo

    2014-04-01

    This study was conducted to evaluate the influence of the implant-abutment connection design and diameter on the screw joint stability. Regular and wide-diameter implant systems with three different joint connection designs: an external butt joint, a one-stage internal cone, and a two-stage internal cone were divided into seven groups (n=5, in each group). The initial removal torque values of the abutment screw were measured with a digital torque gauge. The postload removal torque values were measured after 100,000 cycles of a 150 N and a 10 Hz cyclic load had been applied. Subsequently, the rates of the initial and postload removal torque losses were calculated to evaluate the effect of the joint connection design and diameter on the screw joint stability. Each group was compared using Kruskal-Wallis test and Mann-Whitney U test as post-hoc test (α=0.05). THE POSTLOAD REMOVAL TORQUE VALUE WAS HIGH IN THE FOLLOWING ORDER WITH REGARD TO MAGNITUDE: two-stage internal cone, one-stage internal cone, and external butt joint systems. In the regular-diameter group, the external butt joint and one-stage internal cone systems showed lower postload removal torque loss rates than the two-stage internal cone system. In the wide-diameter group, the external butt joint system showed a lower loss rate than the one-stage internal cone and two-stage internal cone systems. In the two-stage internal cone system, the wide-diameter group showed a significantly lower loss rate than the regular-diameter group (P<.05). The results of this study showed that the external butt joint was more advantageous than the internal cone in terms of the postload removal torque loss. For the difference in the implant diameter, a wide diameter was more advantageous in terms of the torque loss rate.

  18. An Anatomic Investigation of the Ober Test.

    Science.gov (United States)

    Willett, Gilbert M; Keim, Sarah A; Shostrom, Valerie K; Lomneth, Carol S

    2016-03-01

    Recent studies have questioned the importance of the iliotibial band (ITB) in lateral knee pain. The Ober test or modified Ober test is the most commonly recommended physical examination tool for assessment of ITB tightness. No studies support the validity of either Ober test for measuring ITB tightness. The purpose of this study was to assess the effects of progressive transection of the ITB, gluteus medius and minimus (med/min) muscles, and hip joint capsule of lightly embalmed cadavers on Ober test results and to compare them with assessment of all structures intact. In addition, thigh position change between gluteus med/min transection and hip capsule transection was also assessed for both versions of the Ober test. It was hypothesized that transection of the ITB would significantly increase thigh adduction range of motion as measured by an inclinometer when performing either Ober test and that subsequent structure transections (gluteus med/min muscles followed by the hip joint capsule) would cause additional increases in thigh adduction. Controlled laboratory study. The lower limbs of lightly embalmed cadavers were assessed for midthigh ITB transection versus intact by use of the Ober (n = 28) and modified Ober (n = 34) tests; 18 lower limbs were assessed for all conditions (intact band, followed by sequential transections of the ITB midthigh, gluteus med/min muscles, hip joint capsule) by use of both Ober tests. Paired t tests were used to compare changes in Ober test results between conditions. No significant changes in thigh position (adduction) occurred in either version of the Ober test after ITB transection. Significant differences were noted for intact band versus gluteus med/min transection and intact band versus hip joint capsule transection (P well as the hip joint capsule on Ober test findings. The results of this study suggest that the Ober test assesses tightness of structures proximal to the hip joint, such as the gluteus medius and minimus

  19. A Fracture-Based Criterion for Debonding Strength of Adhesive-Bonded Double-Strap Steel Joints

    Directory of Open Access Journals (Sweden)

    Prawit Santisukpotha

    2012-01-01

    Full Text Available This paper addresses the debonding strength of adhesive-bonded double-strap steel joints. A fracture-based criterion was formulated in terms of a stress singularity parameter, i.e., the stress intensity factor, which governs the magnitude of a singular stress field near the joint ends. No existing crack was assumed. A total of 24 steel joint specimens were tested under constant amplitude fatigue loadings at stress ratio of 0.2 and frequency of 2 Hz. The joint stiffness ratio was slightly less than one to control the maximum adhesive stresses at the joint ends. To detect the debonding, a simple and practical technique was developed. The test results showed that the interfacial failure near the steel/adhesive corner was a dominant failure mode. The failure was brittle and the debonding life was governed by the crack initiation stage. The finite element analysis was employed to calculate the stress intensity factors and investigate the effects of the adhesive layer thickness, lap length and joint stiffness ratio on the debonding strength.

  20. Seismic Properties of Moment-resisting Timber Joints with a Combination of Bolts and Nails

    Directory of Open Access Journals (Sweden)

    Awaludin A.

    2011-01-01

    Full Text Available Improvement of cyclic or dynamic performance of timber connections has been intensively conducted since the overall response of wooden structures is merely a function of joint performance. For a bolted joint, filling the lead-hole clearance with epoxy resin or gluing high embedding-strength materials at the interface of the individual timber member are probably the most common methods. This study presents cyclic test results of moment-resisting joints with a combination of bolts and nails. The nails were placed closer to the joint centroid than the bolts, acting as additional fasteners and were expected to improve the seismic performance of the joints. Static-cyclic test results confirmed the increase of joint stiffness and moment resistance due to the additional nails. The nails contribute to the increase of hysteretic damping significantly though pinching behavior or narrowing the hysteresis loops close to zero rotation points was still observed. The results indicated that contribution of nails or bolts on moment resistance and hysteretic damping can be superimposed.

  1. Characteristics of solder joints under fatigue loads using piezomechanical actuation

    Science.gov (United States)

    Shim, Dong-Jin; Spearing, S. Mark

    2003-07-01

    Crack initiation and growth characteristics of solder joints under fatigue loads are investigated using piezomechanical actuation. Cracks in solder joints, which can cause failure in microelectronics components, are induced via piezoelectricity in piezo-ceramic bonded joints. Lead-zirconate-titanate ceramic plates and eutectic Sn-Pb solder bonded in a double-lap shear configuration are used in the investigation. Electric field across each piezo-ceramic plate is applied such that shear stresses/strains are induced in the solder joints. The experiments show that cracks initiate in the solder joints around defects such as voids and grow in length until they coalesce with other cracks from adjacent voids. These observations are compared with the similar thermal cycling tests from the literature to show feasibility and validity of the current method in investigating the fatigue characteristics of solder joints. In some specimens, cracks in the piezo-ceramic plates are observed, and failure in the specimens generally occurred due to piezo-ceramic plate fracture. The issues encountered in implementing this methodology such as low actuation and high processing temperatures are further discussed.

  2. Uniaxial ratcheting behavior of sintered nanosilver joint for electronic packaging

    International Nuclear Information System (INIS)

    Chen, Gang; Yu, Lin; Mei, Yunhui; Li, Xin; Chen, Xu; Lu, Guo-Quan

    2014-01-01

    Uniaxial ratcheting behavior and the fatigue life of sintered nanosilver joint were investigated at room temperature. All tests were carried out under stress-controlled mode. Force–displacement data were recorded during the entire fatigue lifespan by a non-contact displacement detecting system. Effects of stress amplitude, mean stress, stress rate, and stress ratio on the uniaxial ratcheting behavior of the sintered nanosilver joint were discussed. Stress-life (S–N) curves of the sintered joints were also obtained. The Smith–Watson–Topper (SWT) model, the Gerber model and the modified Goodman model, all of which took effect of mean stress into consideration, were compared for predicting the fatigue life of the sintered joint. Both the ratcheting strain and its rate increased with increasing stress amplitude or mean stress. The increase in stress amplitude and mean stress both reduced the fatigue life of the sintered joint, while the fatigue life prolonged with the increase in stress rate and stress ratio. The modified Goodman model predicted the fatigue life of the sintered joints well

  3. The use of joint reinforcement in qualifying masonry walls in nuclear power plants

    International Nuclear Information System (INIS)

    Harris, H.G.; Becica, I.J.; Chokshi, N.C.; Con, V.N.; Hamid, A.A.

    1984-01-01

    Wire joint reinforcement has been traditionally used in block masonry walls for crack control and to provide continuity for multiple wythe walls. In a number of nuclear power plants, vertically unreinforced masonry walls that failed to meet the code allowable stresses for unreinforced masonry were qualified using joint reinforcement as a structural steel to carry lateral loads in the horizontal direction. It is the objective of this paper to examine the adequacy of this approach for seismic load application. A state-of-the-art review of available test data and code design provisions will be presented. It is concluded that the use of joint reinforcement to resist tensile stresses due to seismic loading is questionable because of the lack of test data available and especially the characterization of the cyclic behavior of joint reinforced masonry walls. Further research in this area is recommended

  4. Selenide isotope generators for the Galileo Mission: SIG hermetic bimetal weld transition joint

    International Nuclear Information System (INIS)

    Barnett, W.J.

    1979-08-01

    The successful development of the commercial 6061-T651/Silver/304L explosive clad plate material as a bimetal weld transition joint material, as described herein, satisfies all SIG Galileo design requirements for hermetic weld attachment of stainless steel subassemblies to aluminum alloy generator housing or end cover structures. The application of this type weld transition joint to the hermetic attachment of stainless steel shell connectors is well-developed and tested. Based on on-going life tests of stainless steel receptacle/bimetal ring attachment assemblies and metallurgical characterization studies of this transition joint material, it appears evident that this transition joint material has more than adequate capability to meet the 250 to 300 0 F and 50,000 hr. design life of the SIG/Galileo mission. Its extended life temperture capability may well approach 350 to 400 0 F

  5. Quality control/quality assurance testing for joint density and segregation of asphalt mixtures.

    Science.gov (United States)

    2013-04-01

    Longitudinal joint quality control/assurance is essential to the successful performance of asphalt pavements and it has received considerable amount of attention in recent years. The purpose of the study is to evaluate the level of compaction at the ...

  6. Normal dynamic deformation characteristics of non-consecutive jointed rock masses under impact loads

    Science.gov (United States)

    Zeng, Sheng; Jiang, Bowei; Sun, Bing

    2017-08-01

    In order to study deformation characteristics of non-consecutive single jointed rock masses under impact loads, we used the cement mortar materials to make simulative jointed rock mass samples, and tested the samples under impact loads by the drop hammer. Through analyzing the time-history signal of the force and the displacement, first we find that the dynamic compression displacement of the jointed rock mass is significantly larger than that of the intact jointless rock mass, the compression displacement is positively correlated with the joint length and the impact height. Secondly, the vertical compressive displacement of the jointed rock mass is mainly due to the closure of opening joints under small impact loads. Finally, the peak intensity of the intact rock mass is larger than that of the non-consecutive jointed rock mass and negatively correlated with the joint length under the same impact energy.

  7. Prevalence of joint contractures and muscle weakness in people with multiple sclerosis.

    Science.gov (United States)

    Hoang, Phu Dinh; Gandevia, Simon C; Herbert, Robert D

    2014-01-01

    To investigate the prevalence of joint contracture (limited passive range of joint motion) and muscle weakness in a population with multiple sclerosis (MS). A secondary aim was to establish normative data of functional tests of mobility and balance of people with MS who are still ambulant. Cross-sectional study. People with MS living in metropolitan Sydney, Australia. 330 people with MS living in metropolitan Sydney, Australia were randomly sampled on 23 July 2009 from the MS Australia register and invited to participate. Passive range of motion of large joints of the limbs and muscle strength. Tests of walking and balance were also conducted. 156 people (109 females, 47 males; mean age 54.2 years; mean time since diagnosis 14.9 years) agreed to participate and were assessed. Fifty-six per cent (56%) of participants had contracture in at least one major joint of upper or lower limb. The most common site of contracture was the ankle (43.9%). Seventy per cent (70%) of participants had muscle weakness in one or more muscle groups. As muscle weakness, joint contractures were present at early stage of MS and the prevalence was associated with the progression of the disease. These data show that in addition to muscle weakness joint contractures are highly prevalent among people with MS, especially in the ankle joint. This implicates that prevention of contracture is crucial in providing rehabilitation to people with MS.

  8. Fatigue strength of socket welded pipe joint

    International Nuclear Information System (INIS)

    Iida, K.; Matsuda, F.; Sato, M.; Higuchi, M.; Nakagawa, A.

    1994-01-01

    Fully reversed four point bending fatigue tests were carried out of small diameter socket welded joints made of carbon steels. Experimental parameters are pipe diameter, thickness of pipe and socket wall, throat depth and shape of fillet welds, slip-on and diametral gaps in the socket welding, lack of penetration at the root of fillet welds, and peening of fillet welds. In most cases a fatigue crack started from the root of the fillet, but in the case of higher stress amplitude, it tended to start from the toe of fillet. The standard socket welded joint of 50 mm diameter showed relatively low fatigue strength, 46 MPa in stress amplitude at the 10 7 cycles failure life. This value corresponds to about 1/5 of that of the smoothed base metal specimens in axial fatigue. The fatigue strength showed decrease with increasing pipe diameter, and increase with increasing the thickness of pipe and socket wall. The effects of throat depth and shape of fillet welds on fatigue strength were not significant. Contrary to the expectation, the fatigue strength of the socket welded joint without slip-on gap is higher than that of the joint with the normal gap. A lack of penetration at the root deleteriously reduced fatigue strength, showing 14 MPa in stress amplitude at the 10 7 cycles failure life for the 50 mm diameter socket joint. (orig.)

  9. The tensile strength of mechanical joint prototype of lontar fiber composite

    Science.gov (United States)

    Bale, Jefri; Adoe, Dominggus G. H.; Boimau, Kristomus; Sakera, Thomas

    2018-03-01

    In the present study, an experimental activity has been programmed to investigate the effect of joint prototype configuration on tensile strength of lontar (Borassus Flabellifer) fiber composite. To do so, a series of tests were conducted to establish the tensile strength of different joint prototype configuration specimen of lontar fiber composite. In addition, post observation of macroscope was used to map damage behavior. The analysis of lontar fiber composite is a challenge since the material has limited information than others natural fiber composites materials. The results shown that, under static tensile loading, the tensile strength of 13 MPa produced by single lap joint of lontar fiber composite is highest compare to 11 MPa of tensile strength generated by step lap joint and double lap joint where produced the lowest tensile strength of 6 MPa. It is concluded that the differences of tensile strength depend on the geometric dimensions of the cross-sectional area and stress distribution of each joint prototype configuration.

  10. Does generalized joint hypermobility predict joint injury in sport? A review.

    LENUS (Irish Health Repository)

    Donaldson, Peter R

    2012-02-01

    OBJECTIVE: To determine whether persons with generalized joint hypermobility have an increased risk of lower limb joint injury during sport. DATA SOURCES: PubMed, CINAHL, EMBASE, and SportDiscus were searched through February 2009, without language restrictions, using terms related to risk; hip, ankle, and knee injuries; and joint instability. Reference lists of included studies and relevant reviews were searched by hand. STUDY SELECTION: Selection criteria were peer-reviewed studies with a prospective design that used an objective scale to measure generalized joint hypermobility; the participants were engaged in sport activity, and the injury data were quantitative and based on diagnosis by a health professional, were self-reported, or resulted in time lost to athletic participation. The studies were screened by 1 researcher and checked by a second. Study methods were independently assessed by 2 investigators using the 6-point scale for prognostic studies developed by Pengel. Disagreements were resolved through discussion. Of 4841 studies identified, 18 met inclusion criteria. Of these, 8 were included in random-effects meta-analyses. DATA EXTRACTION: The data extracted by 2 reviewers included participant and sport characteristics and details of joint hypermobility and injury measurements. More detailed data for 4 investigations were obtained from the study authors. Where possible, hypermobility was defined as >\\/=4 of 9 points on the British Society of Rheumatology Scale (BSRS). MAIN RESULTS: Lower limb joint injuries (3 studies, 1047 participants) occurred in 14% of participants. Using the BSRS of joint hypermobility, any lower limb injury was not associated with hypermobility [odds ratio (OR), 1.43; 95% confidence interval (CI), 0.56-3.67]. Using the original authors\\' definitions, hypermobility was associated with risk of knee joint injuries (OR, 2.62; 95% CI, 1.04-6.58) in 5 studies. In 4 studies in which the BSRS could be used (1167 participants; incidence

  11. Joint attention, social cognition and recognition memory in adults

    Directory of Open Access Journals (Sweden)

    Kwanguk eKim

    2012-06-01

    Full Text Available The early emerging capacity for Joint Attention, or socially coordinated visual attention, is thought to be integral to the development of social-cognition in childhood. Recent studies have also begun to suggest that joint attention affects adult cognition as well, but methodological limitations hamper research on this topic. To address this issue we developed a novel virtual reality (VR paradigm that integrates eye-tracking and virtual avatar technology to measure two types of joint attention in adults, Initiating Joint Attention (IJA and Responding to Joint Attention (RJA. Distinguishing these types of joint attention in research is important because they are thought to reflect unique, as well as common constellations of processes involved in human social-cognition and social learning. We tested the validity of the differentiation of IJA and RJA in our paradigm in two studies of picture recognition memory in undergraduate students. Study 1 indicated that young adults correctly identified more pictures they had previously viewed in an IJA condition (67% than in a RJA (58% condition, η2 = .57. Study 2 controlled for IJA and RJA stimulus viewing time differences, and replicated the findings of Study 1. The implications of these results for the validity of the paradigm and research on the affects of joint attention on adult social-cognition are discussed.

  12. Finite element analysis for friction noise of simplified hip joint and its experimental validation

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Jae Hyun; Choi, Hoil; Kang, Jae Young [Div. of Mechanical and Automotive Engineering, College of Engineering, Kongju National University, Cheonan (Korea, Republic of)

    2016-08-15

    In a hip joint system, squeak noise often occurs due to friction between the ball and hemispherical cup. To analyze the dynamic instability induced by friction in the hip joint system, the dynamic ball joint model was constructed by using the finite element method. The results from stability analysis revealed that the mode-coupling type instability occurred for one bending mode and its adjacent composite mode with the axial and transverse displacements with the increase of friction coefficient. The vitro squeak test and vibration modal tests confirmed that squeak arose near the frequency of the mode pair.

  13. Specific adaptations of neuromuscular control and knee joint stiffness following sensorimotor training.

    Science.gov (United States)

    Gruber, M; Bruhn, S; Gollhofer, A

    2006-08-01

    The aim of this study was to examine how fixations of the ankle joint during sensorimotor training (SMT) influence adaptations in mechanical stiffness and neuromuscular control of the knee joint. Sixty-three healthy subjects were randomly assigned to three training groups that differed in their degree of ankle joint fixation, which was either barefooted, with an ankle brace or with a ski boot. Mechanical knee joint stiffness and reflex control of m. vastus medialis, m. vastus lateralis, m. biceps femoris, and m. semitendinosus were tested during force controlled anterior tibial displacements. This force was applied as both a fast and a slow stimulus. After the training period the group that trained barefooted showed an increase in mechanical stiffness of the knee joint from 79 +/- 21 (Mean +/- SD) N/mm to 110 +/- 38 N/mm (p boots was able to improve knee joint stiffness from 67 +/- 26 N/mm to 96 +/- 47 N/mm (p knee joint injuries.

  14. Strength scaling of adhesive joints in polymer–matrix composites

    DEFF Research Database (Denmark)

    Sørensen, Bent F.; Goutianos, Stergios; Jacobsen, Torben K.

    2009-01-01

    The fracture of adhesive joints between two glass-fibre laminates was studied by testing double cantilever beam test specimens loaded by uneven bending moments. A large-scale fracture process zone, consisting of a crack tip and a fibre bridging zone, developed. The mixed mode fracture resistance...

  15. The joint flanker effect and the joint Simon effect: On the comparability of processes underlying joint compatibility effects.

    Science.gov (United States)

    Dittrich, Kerstin; Bossert, Marie-Luise; Rothe-Wulf, Annelie; Klauer, Karl Christoph

    2017-09-01

    Previous studies observed compatibility effects in different interference paradigms such as the Simon and flanker task even when the task was distributed across two co-actors. In both Simon and flanker tasks, performance is improved in compatible trials relative to incompatible trials if one actor works on the task alone as well as if two co-actors share the task. These findings have been taken to indicate that actors automatically co-represent their co-actor's task. However, recent research on the joint Simon and joint flanker effect suggests alternative non-social interpretations. To which degree both joint effects are driven by the same underlying processes is the question of the present study, and it was scrutinized by manipulating the visibility of the co-actor. While the joint Simon effect was not affected by the visibility of the co-actor, the joint flanker effect was reduced when participants did not see their co-actors but knew where the co-actors were seated. These findings provide further evidence for a spatial interpretation of the joint Simon effect. In contrast to recent claims, however, we propose a new explanation of the joint flanker effect that attributes the effect to an impairment in the focusing of spatial attention contingent on the visibility of the co-actor.

  16. Finger jointing green southern yellow pine with a soy-based adhesive

    Science.gov (United States)

    Philip H. Steele; Roland E. Kreibicha; Petrus J. Steynberg; Richard W. Hemingway

    1998-01-01

    The authors present results of laboratory tests for a soy-based adhesive to bond southern yellow pine using the finger-jointing method. There was some reason to suspect that finger jointing of southern yellow pine (SYP) with the honeymoon system using soy-based adhesive might prove more difficult than for western species. The Wood Handbook classes western species in...

  17. A Modelling Method of Bolt Joints Based on Basic Characteristic Parameters of Joint Surfaces

    Science.gov (United States)

    Yuansheng, Li; Guangpeng, Zhang; Zhen, Zhang; Ping, Wang

    2018-02-01

    Bolt joints are common in machine tools and have a direct impact on the overall performance of the tools. Therefore, the understanding of bolt joint characteristics is essential for improving machine design and assembly. Firstly, According to the experimental data obtained from the experiment, the stiffness curve formula was fitted. Secondly, a finite element model of unit bolt joints such as bolt flange joints, bolt head joints, and thread joints was constructed, and lastly the stiffness parameters of joint surfaces were implemented in the model by the secondary development of ABAQUS. The finite element model of the bolt joint established by this method can simulate the contact state very well.

  18. Peripheral degenerative joint diseases

    Directory of Open Access Journals (Sweden)

    Nilzio Antonio da Silva

    2008-03-01

    Full Text Available Osteoarthritis, a degenerative joint disease, is the most commonrheumatic disorder mainly in a geriatric population. Manifestationsare pain, stiffness and functional loss in the affected joint.According to etiology it is classifi ed as primary (or idiopathicand secondary. Some risk factors for disease development aregenetics, race, age, sex, obesity, occupational activities andarticular biomechanics. Pathogenesis is the same for any cause orlocalization, being catabolic alterations, with synthesis, inhibitionand reparing intent of the cartilage matrix. Metalloproteinases andcytokines (IL-1,IL-6,TNF-α actions promote infl ammatory reactionand cartilage degradation. Pain, the most important symptom,does not correlate with radiologic fi ndings. Peripheral osteoarthritisoccurs predominantly in the knee, hip and hand. Diagnosis is basedon clinical features, laboratorial tests and radiological changes.Rheumatological associations’ guidelines for treatment includenon-pharmacologic (education, physiotherapy, assistive devices,and pharmacologic (analgesics, anti-infl ammatory drugs therapyand surgery. Arthroplasty seems to work better than medicines, butshould be used if other treatments have failed.

  19. Technological aspects of manufacturing and numerical modelling of clinch-adhesive joints

    CERN Document Server

    Sadowski, Tomasz; Golewski, Przemysław

    2015-01-01

    This short book describes the basic technological aspects involved in the creation of purely clinch and clinch-adhesive joints made of different types of adherent materials and employing different joining technologies. Basic parameters that need to be taken into account in the design process are also presented, while a comparison of experimental testing of the hybrid joint with simple clinching for a combination of different joining materials underlines the advantages of opting for hybrid joints. The book’s conclusions will facilitate the practical application of this new fastening technology.

  20. Impact properties of reduced activation ferritic/martensitic steel, F82H jointed by hot isostatic pressing

    Energy Technology Data Exchange (ETDEWEB)

    Ogiwara, H.; Tanigawa, H. [Japan Atomic Energy Agency, Tokai-mura, Naga-gun, Ibaraki-ken (Japan); Hirose, T. [Blanket Engineering Group, Japan Atomic Energy Agency, Naka, Ibaraki (Japan); Enoeda, M. [Naka Fusion Research Establishment, J.A.E.R.I., Japan Atomic Energy Research Institute, Ibaraki-ken (Japan); Kohyama, A. [Kyoto Univ., lnstitute of Advanced Energy (Japan)

    2007-07-01

    Full text of publication follows: Reduced-activation ferritic/martensitic steels are the leading candidate structural material for the blanket system of fusion reactors. The important issue at the current stage is the finalization of a detailed manufacturing specification for ITER test blanket module. Hot isostatic pressing (HIP) process is one of the most important methods to fabricate the first wall with cooling channels. The objective of this paper is to optimize HIP condition to obtain the excellent joints mechanical properties. The materials used were F82H steels. The joint was produced by solid state HIP method. Before HIP treatments, specimens were heated in vacuum condition to out-gas. This treatment was conducted to decrease oxidation on the surfaces. HIP treatments were carried out for 2 h at 1100 deg. C - 140 MPa. The specimens were normalized at 960 deg. C for 0.5 h and tempered at 750 deg. C for 1.5 h. The bonding interface was characterized by scanning electron microscopy. Charpy impact tests and tensile tests were conducted to evaluate the mechanical properties of the HIP joint. Impact tests revealed that there were no significant differences in the ductile-brittle transition temperatures of HIP jointed specimens and base metal specimens, but the upper-shelf energy (USE) of the HIP joint specimens at room temperature was only about 10% of that of the base metal specimens. SEM observations of the fracture surface of HIP joint specimens revealed that a large number of oxides were formed on the HIP joint. This result indicates that oxides formed on the HIP joint are the dominant factor of the impact properties. Based on these results, the pre-HIP treatment conditions had been optimized to reduce the number of oxides, and USE of HIP joint specimens increased to about 50% of that of the base metal. The detailed analyses on the HIP joint microstructure will be reported. (authors)

  1. Glass Masonry - Experimental Verification of Bed Joint under Shear

    Science.gov (United States)

    Fíla, J.; Eliášová, M.; Sokol, Z.

    2017-10-01

    Glass is considered as a traditional material for building industry but was mostly used for glazing of the windows. At present, glass is an integral part of contemporary architecture where glass structural elements such as beams, stairs, railing ribs or columns became popular in the last two decades. However, using glass as structural material started at the beginning of 20th century, when masonry from hollow glass blocks were used. Using solid glass brick is very rare and only a few structures with solid glass bricks walls have been built in the last years. Pillars and walls made from solid glass bricks are mainly loaded by compression and/or bending from the eccentricity of vertical load or wind load. Due to high compressive strength of glass, the limiting factor of the glass masonry is the joint between the glass bricks as the smooth surface requires another type of mortar / glue compared to traditional masonry. Shear resistance and failure modes of brick bed joint was determined during series of tests using various mortars, two types of surface treatment and different thickness of the mortar joint. Shear tests were completed by small scale tests for mortar - determination of flexural and compressive strength of hardened mortar.

  2. Joint ventures

    DEFF Research Database (Denmark)

    Sørensen, Karsten Engsig

    Afhandlingen analysere de konkurrenceretlige og selskabsretlige regler som er bestemmende for hvordan et joint venture samarbejde er struktureret......Afhandlingen analysere de konkurrenceretlige og selskabsretlige regler som er bestemmende for hvordan et joint venture samarbejde er struktureret...

  3. High temperature strength analysis of welded joint of RAF's by small punch test

    Energy Technology Data Exchange (ETDEWEB)

    Kato, T. [Muroran Institute of Technology, Dept. of Materials Science and Engineeering, Hokkaido (Japan); Komazaki, S.; Kohno, Y. [Muroran Institute of Technology, Muroran (Japan); Tanigawa, H. [Japan Atomic Energy Agency, Naga-gun, Ibaraki-ken (Japan); Kohyama, A. [Kyoto Univ., Institute of Advanced Energy (Japan)

    2007-07-01

    Full text of publication follows: Nucleation and growth of microvoids and/or small cracks in fine-grained heat affected zone (HAZ) after long-term service operation, which is recognized as Type IV creep damage, has recently been a worldwide issue for high Cr ferritic steels. In our group, a small punch (SP) creep test has been successfully applied to evaluate this damage of low alloy ferritic steel. However, the HAZ of fusion reactor material welded by electron-beam (EB) welding is so narrow that it is not easy to evaluate its mechanical properties by conventional tests including the SP creep test with a plate-type specimen (10 x 10 x 0.5 mm{sup 3}). In this study, the SP creep test using a further miniaturized specimen was developed and applied to the welded joint of reduced activation ferritic steels (RAFs), F82H-IEA (Fe-8Cr-2W-0.2V-0.02Ta), for measuring creep properties of the HAZ. For the SP creep test, TEM disk-type samples (diam. 3.0 x 0.30 mm) were removed from the base metal (BM), weld metal (WM) and HAZ, respectively. The specimen surfaces were polished up to a 0.05 {mu}m alumina powder finish and the specimen's thickness was finally adjusted to 0.25 mm. The SP creep tests were performed at temperatures of 823{approx}973 K and under loads ranging from 20 to 200 N. A constant load was applied to the center of the specimen through the Si{sub 3}N{sub 4} bail (diam. 1.0 mm) using the electric servo motor. The central deflection of the specimen was monitored by measuring the displacement of the compression rod. The tests were carried out in an argon gas atmosphere and the gas was continuously passed through during the test to prevent severe oxidation of the specimen. The differences in SP creep properties such as rupture time and minimum creep rate between the BM, WM and HAZ were discussed in terms of microstructural changes during welding thermal cycles. In addition, the result obtained from the BM was correlated with those of uniaxial creep test

  4. The effects of welded joint characteristics on its properties in HDPE thermal fusion welding

    Science.gov (United States)

    Dai, Hongbin; Peng, Jun

    2017-05-01

    In this paper, PE100 pipes with the diameter of 200 mm and the thickness of 11.9 mm were used as material. The welded joints were obtained in different welding pressures with the optimal welding temperature of 220∘C. Reheating process on the welded joints with the temperature of 130∘C was carried out. The joints exhibited X-type, and the cause of X-type joints was discussed. The temperature field in the forming process of welded joints was measured, and tensile and bending tests on welded joints were carried out. The fracture surface of welded joints was observed by scanning electron microscopy (SEM), and crystallinity calculation was taken by X-ray diffraction (XRD). The mechanism of X-type weld profile effects on welded joints properties was analyzed. It was concluded that the mechanical properties of welded joints decrease with the reduced X distance between lines.

  5. Dynamic Postural-Stability Deficits After Cryotherapy to the Ankle Joint

    Science.gov (United States)

    Fullam, Karl; Caulfield, Brian; Coughlan, Garrett F.; McGroarty, Mark; Delahunt, Eamonn

    2015-01-01

    Context  Decreased postural stability is a primary risk factor for lower limb musculoskeletal injuries. During athletic competitions, cryotherapy may be applied during short breaks in play or during half-time; however, its effects on postural stability remain unclear. Objective  To investigate the acute effects of a 15-minute ankle-joint cryotherapy application on dynamic postural stability. Design  Controlled laboratory study. Setting  University biomechanics laboratory. Patients or Other Participants  A total of 29 elite-level collegiate male field-sport athletes (age = 20.8 ± 1.12 years, height = 1.80 ± 0.06 m, mass = 81.89 ± 8.59 kg) participated. Intervention(s)  Participants were tested on the anterior (ANT), posterolateral (PL), and posteromedial (PM) reach directions of the Star Excursion Balance Test before and after a 15-minute ankle-joint cryotherapy application. Main Outcome Measure(s)  Normalized reach distances; sagittal-plane kinematics of the hip, knee, and ankle joints; and associated mean velocity of the center-of-pressure path during performance of the ANT, PL, and PM reach directions of the Star Excursion Balance Test. Results  We observed a decrease in reach-distance scores for the ANT, PL, and PM reach directions from precryotherapy to postcryotherapy (P .05). We noted a decrease in mean velocity of the center-of-pressure path from precryotherapy to postcryotherapy (P cryotherapy to the ankle joint. PMID:26285088

  6. Space suit glove design with advanced metacarpal phalangeal joints and robotic hand evaluation.

    Science.gov (United States)

    Southern, Theodore; Roberts, Dustyn P; Moiseev, Nikolay; Ross, Amy; Kim, Joo H

    2013-06-01

    One area of space suits that is ripe for innovation is the glove. Existing models allow for some fine motor control, but the power grip--the act of grasping a bar--is cumbersome due to high torque requirements at the knuckle or metacarpal phalangeal joint (MCP). This area in particular is also a major source of complaints of pain and injury as reported by astronauts. This paper explores a novel fabrication and patterning technique that allows for more freedom of movement and less pain at this crucial joint in the manned space suit glove. The improvements are evaluated through unmanned testing, manned testing while depressurized in a vacuum glove box, and pressurized testing with a robotic hand. MCP joint flex score improved from 6 to 6.75 (out of 10) in the final glove relative to the baseline glove, and torque required for flexion decreased an average of 17% across all fingers. Qualitative assessments during unpressurized and depressurized manned testing also indicated the final glove was more comfortable than the baseline glove. The quantitative results from both human subject questionnaires and robotic torque evaluation suggest that the final iteration of the glove design enables flexion at the MCP joint with less torque and more comfort than the baseline glove.

  7. Preliminary Design and Analysis of an In-plane PRSEUS Joint

    Science.gov (United States)

    Lovejoy, Andrew E.; Poplawski, Steven

    2013-01-01

    As part of the National Aeronautics and Space Administration's (NASA's) Environmentally Responsible Aviation (ERA) program, the Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) has been designed, developed and tested. However, PRSEUS development efforts to date have only addressed joints required to transfer bending moments between PRSEUS panels. Development of in-plane joints for the PRSEUS concept is necessary to facilitate in-plane transfer of load from PRSEUS panels to an adjacent structure, such as from a wing panel into a fuselage. This paper presents preliminary design and analysis of an in-plane PRSEUS joint for connecting PRSEUS panels at the termination of the rod-stiffened stringers. Design requirements are provided, the PRSEUS blade joint concept is presented, and preliminary design changes and analyses are carried out to examine the feasibility of the proposed in-plane PRSEUS blade joint. The study conducted herein focuses mainly on the PRSEUS structure on one side of the joint. In particular, the design requirements for the rod shear stress and bolt bearing stress are examined. A PRSEUS blade joint design was developed that demonstrates the feasibility of this in-plane PRSEUS joint concept to terminate the rod-stiffened stringers. The presented design only demonstrates feasibility, therefore, some areas of refinement are presented that would lead to a more optimum and realistic design.

  8. Experimental and Computational Modal Analyses for Launch Vehicle Models considering Liquid Propellant and Flange Joints

    Directory of Open Access Journals (Sweden)

    Chang-Hoon Sim

    2018-01-01

    Full Text Available In this research, modal tests and analyses are performed for a simplified and scaled first-stage model of a space launch vehicle using liquid propellant. This study aims to establish finite element modeling techniques for computational modal analyses by considering the liquid propellant and flange joints of launch vehicles. The modal tests measure the natural frequencies and mode shapes in the first and second lateral bending modes. As the liquid filling ratio increases, the measured frequencies decrease. In addition, as the number of flange joints increases, the measured natural frequencies increase. Computational modal analyses using the finite element method are conducted. The liquid is modeled by the virtual mass method, and the flange joints are modeled using one-dimensional spring elements along with the node-to-node connection. Comparison of the modal test results and predicted natural frequencies shows good or moderate agreement. The correlation between the modal tests and analyses establishes finite element modeling techniques for modeling the liquid propellant and flange joints of space launch vehicles.

  9. A New Method for Determination of Joint Roughness Coefficient of Rock Joints

    Directory of Open Access Journals (Sweden)

    Shigui Du

    2015-01-01

    Full Text Available The joint roughness coefficient (JRC of rock joints has the characteristic of scale effect. JRC measured on small-size exposed rock joints should be evaluated by JRC scale effect in order to obtain the JRC of actual-scale rock joints, since field rock joints are hardly fully exposed or well saved. Based on the validity analysis of JRC scale effect, concepts of rate of JRC scale effect and effective length of JRC scale effect were proposed. Then, a graphic method for determination of the effective length of JRC scale effect was established. Study results show that the JRC of actual-scale rock joints can be obtained through a fractal model of JRC scale effect according to the statistically measured results of the JRC of small-size partial exposed rock joints and by the selection of fractal dimension of JRC scale effect and the determination of effective length of JRC scale effect.

  10. Experimental verification of lifetime of bolting joints for WWER reactor pressure vessels

    International Nuclear Information System (INIS)

    Brumovsky, M.; Polachova, H.

    1992-01-01

    This paper presents results from experimental verification of cyclic lifetime of bolting joints of M 140x6 mm type used for WWER-440 MW reactor pressure vessels. Bolting joints or real dimensions were tested in a special testing equipment ZS 1000 in Skoda Concern. Stud bolts are made from 25Kh1MF or 38KhN3MFA type of steels. Tests were carried out at operating as well as at room temperatures with coefficient of asymmetry equal to 0.1; one tests was realized with given bending moment. Experimental results have been compared with calculated lifetimes according to ASME, Soviet and CMEA Codes. In all cases calculations give conservative assessments. (orig.)

  11. Cryotherapy does not impair shoulder joint position sense.

    Science.gov (United States)

    Dover, Geoffrey; Powers, Michael E

    2004-08-01

    To determine the effects of a cryotherapy treatment on shoulder proprioception. Crossover design with repeated measures. University athletic training and sports medicine research laboratory. Thirty healthy subjects (15 women, 15 men). A 30-minute cryotherapy treatment. Joint position sense was measured in the dominant shoulder by using an inclinometer before and after receiving 30 minutes of either no ice or a 1-kg ice bag application. Skin temperature was measured below the tip of the acromion process and recorded every 5 minutes for the entire 30 minutes and immediately after testing. Three different types of error scores were calculated for data analyses and used to determine proprioception. Separate analyses of absolute, constant, and variable error failed to identify changes in shoulder joint proprioception as a function of the cryotherapy application. Application of an ice bag to the shoulder does not impair joint position sense. The control of proprioception at the shoulder may be more complex than at other joints in the body. Clinical implications may involve modifying rehabilitation considerations when managing shoulder injuries.

  12. The Influence of the Heat-Affected Zone Mechanical Properties on the Behaviour of the Welding in Transverse Plate-to-Tube Joints.

    Science.gov (United States)

    Lozano, Miguel; Serrano, Miguel A; López-Colina, Carlos; Gayarre, Fernando L; Suárez, Jesús

    2018-02-09

    Eurocode 3 establishes the component method to analytically characterize the structural joints between beam and columns. When one of the members involved in the joint is a hollow section (i.e., a tube) there is a lack of information for the specific components present in the joint. There are two different ways to bridge the gap: experimental testing on the actual beam column joints involving tubular sections; or numerical modelization, typically by means of finite element analysis. For this second option, it is necessary to know the actual mechanical properties of the material. As long as the joint implies a welding process, there is a concern related to how the mechanical properties in the heat-affected zone (HAZ) influence the behavior of the joint. In this work, some coupons were extracted from the HAZ of the beam-column joint. The coupons were tested and the results were implemented in the numerical model of the joint, in an attempt to bring it closer to the experimental results of the tested joints.

  13. Tensile strength and fatigue strength of 6061 aluminum alloy friction welded joints

    Energy Technology Data Exchange (ETDEWEB)

    Ochi, H.; Tsujino, R. [Osaka Inst. of Tech., Asahi-ku Osaka (Japan); Sawai, T. [Osaka Sangyo Univ., Daito (Japan); Yamamoto, Y. [Setsunan Univ., Neyagawa (Japan); Ogawa, K. [Osaka Prefecture Univ., Sakai (Japan); Suga, Y. [Keio Univ., Kohoku-ku, Yokohama (Japan)

    2002-07-01

    Friction welding of 6061 aluminum alloy was carried out in order to examine the relationship between deformation heat input in the upset stage and joint performance. The joint performance was evaluated by tensile testing and fatigue testing. Stabilized tensile strength was obtained when the deformation heat input in the upset stage exceeded 200 J/s. Weld condition at the weld interface and the width of softened area affected fatigue strength more than tensile strength. That is, when the weld condition at the weld interface is good and the softened area is wide, fatigue strength increases. On the other hand, when the weld condition at the weld interface is good and the softened area is narrow, and when the weld condition at the weld interface is somewhat poor in spite of the wide softened area, fatigue strength decreases. The fatigue limit obtained by the fatigue testing revealed that, when the deformation heat input in the upset stage exceeded a certain value, sound joints could be produced. (orig.)

  14. Intensity rankings of plyometric exercises using joint power absorption.

    Science.gov (United States)

    Van Lieshout, Kathryn G; Anderson, Joy G; Shelburne, Kevin B; Davidson, Bradley S

    2014-09-01

    Athletic trainers and physical therapists often progress patients through rehabilitation by selecting plyometric exercises of increasing intensity in preparation for return to sport. The purpose of this study was to quantify the intensity of seven plyometric movements commonly used in lower-extremity rehabilitation by joint-specific peak power absorption and the sum of the peak power. Ten collegiate athletes performed submaximal plyometric exercises in a single test session: vertical jump, forward jump, backward jump, box drop, box jump up, tuck jump, and depth jump. Three-dimensional kinematics and force platform data were collected to generate joint kinetics. Peak power absorption normalized to body mass was calculated at the ankle, knee, and hip, and averaged across repetitions. Joint peak power data were pooled across athletes and summed to obtain the sum of peak power. Movements were ranked from 1 (low) to 7 (high) based on the sum of peak power and joint peak power (ankle, knee, hip). The sum of peak power did not correspond with standard low, medium, and high subjective intensity ratings or joint peak power in all joints. Mixed model analyses revealed significant variance between the sum of peak power and joint peak power ranks in the forward jump, backward jump, box drop, and depth jump (P<0.05), but not in the vertical jump, box jump up, and tuck jump. Results provide intensity rankings that can be used directly by athletic trainers and physical therapists in developing protocols for rehabilitation specific to the injured joint. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Numerical design and test on an assembled structure of a bolted joint with viscoelastic damping

    Science.gov (United States)

    Hammami, Chaima; Balmes, Etienne; Guskov, Mikhail

    2016-03-01

    Mechanical assemblies are subjected to many dynamic loads and modifications are often needed to achieve acceptable vibration levels. While modifications on mass and stiffness are well mastered, damping modifications are still considered difficult to design. The paper presents a case study on the design of a bolted connection containing a viscoelastic damping layer. The notion of junction coupling level is introduced to ensure that sufficient energy is present in the joints to allow damping. Static performance is then addressed and it is shown that localization of metallic contact can be used to meet objectives, while allowing the presence of viscoelastic materials. Numerical prediction of damping then illustrates difficulties in optimizing for robustness. Modal test results of three configurations of an assembled structure, inspired by aeronautic fuselages, are then compared to analyze the performance of the design. While validity of the approach is confirmed, the effect of geometric imperfections is shown and stresses the need for robust design.

  16. THE RELATIONSHIP BETWEEN TEMPOROMANDIBULAR-JOINT MOBILITY AND PERIPHERAL JOINT MOBILITY RECONSIDERED

    NARCIS (Netherlands)

    Dijkstra, P.U.; DEBONT, L.G.M.; VANDERWEELE, L.T.; Boering, G.

    The purpose of this paper was to study the relationship between temporomandibular joint (TMJ) mobility and mobility of joints and to study the general character of joint mobility in 83 subjects, 55 females and 28 males (mean age 26.7, range 13-46 years). The subjects were recruited from the

  17. Dual joint space arthrography in temporomandibular joint disorders: Comparison with single inferior joint space arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hyung Sik; Chang, Duk Soo; Lee, Kyung Soo; Kim, Woo Sun; Sung, Jung Ho; Jun, Young Hwan [Capital Armed Forces General Hospital, Seoul (Korea, Republic of)

    1989-02-15

    The temporomandibular joint(TMJ) is really a complex of two synovial space separated by fibrocartilaginous disc. Single inferior joint space arthrography is commonly performed for evaluation of TMJ disorders, which is known to be superior in demonstrating joint dynamics. But it reveals only the inferior surface of the disc. Therefore, dual space arthrography is superior to demonstrate the soft tissue anatomic feature of the joint such as disc position and shape. Authors performed 83 TMJ arthrograms in TMJ problems. Initially, the inferior joint space was done and then the superior space was sequentially contrasted. The follow results were noted: 1. In all cases, dual space arthrography revealed accurate disc shape and positions. 2. Concordant findings between the two techniques: 68 cases (82%). Discordance between the two techniques: 15 cases (18%) 3. Possible causes of discordance between inferior and dual space arthrography. a) Normal varians of anterior recess: 3 cases b) Posterior disc displacement: 4 cases c) Influence of the patient's head position change :4 cases d) False perforation: 2 cases e) Reduction change: 2 cases 4. In 5 cases with anterior displacement, dual space arthrography gave additional findings such as adhesion within the superior space, which could not be evaluated by single inferior space.

  18. Effect of the weld joint configuration on stressed components, residual stresses and mechanical properties

    Energy Technology Data Exchange (ETDEWEB)

    Cevik, Bekir; Oezer, Alpay; Oezcatalbas, Yusuf [Gazi Univ., Ankara (Turkey)

    2014-03-01

    The effect of the weld joint configuration on components has been studied, which are under service loads, under repair or construction and the residual stresses as well as the mechanical properties of the joint have been determined. For this purpose, a horizontal positioned tensile testing device and a semi-automatic MIG welding machine have been used and then the weld joints of the plates were subjected to different elastic stresses. When the temperature of the joined elements decreased to room temperature, applied elastic stresses were released. By this means, the effects of the existing tensile stresses in the joined parts and the tensile stresses created by the welding processes were investigated. The tensile stresses occurring in the joined elements were determined by using the photo-elasticity analysis method and the hole-drilling method. Also, tensile-shear tests were applied in order to determine the effect of permanent tensile loads on the mechanical properties of the joint. Experimental results showed that the application of corner welded lap joints for components under tensile loading significantly decrease the shear strength and yielding capacities of the joint. (orig.)

  19. Enhancement of mechanical properties and corrosion resistance of friction stir welded joint of AA2014 using water cooling

    Energy Technology Data Exchange (ETDEWEB)

    Sinhmar, S., E-mail: sinhmarsunil88@gmail.com; Dwivedi, D.K.

    2017-01-27

    An investigation on the microstructure, mechanical properties, and corrosion behavior of friction stir welded joint of AA2014 in natural cooled (NC) and water cooled (WC) conditions have been reported. Optical microscopy, field emission scanning electron microscopy (FESEM) with Energy dispersive X-ray spectroscopy (EDS), Vicker's microhardness, tensile testing, X-ray diffraction (XRD), and electrochemical potentiodynamic polarization corrosion test (Tafel curve) were carried out to characterize the friction stir weld joints in both the cooling conditions. Water cooling resulted in higher strength and microhardness of friction stir weld joint compared to the natural cooling. The width of heat affected zone was reduced by the use of water cooling during friction stir welding (FSW) and minimum hardness zone was shifted towards weld center. The corrosion test was performed in 3.5% NaCl solution. Corrosion resistance of water cooled joint was found higher than natural cooled FSW joint. The precipitation behavior of weld nugget and heat affected zone impacts the corrosion resistance of FSW joint of AA 2014. Hardness, tensile, and corrosion properties of FSW joints produced under NC and WC conditions have been discussed in the light of microstructure.

  20. Enhancement of mechanical properties and corrosion resistance of friction stir welded joint of AA2014 using water cooling

    International Nuclear Information System (INIS)

    Sinhmar, S.; Dwivedi, D.K.

    2017-01-01

    An investigation on the microstructure, mechanical properties, and corrosion behavior of friction stir welded joint of AA2014 in natural cooled (NC) and water cooled (WC) conditions have been reported. Optical microscopy, field emission scanning electron microscopy (FESEM) with Energy dispersive X-ray spectroscopy (EDS), Vicker's microhardness, tensile testing, X-ray diffraction (XRD), and electrochemical potentiodynamic polarization corrosion test (Tafel curve) were carried out to characterize the friction stir weld joints in both the cooling conditions. Water cooling resulted in higher strength and microhardness of friction stir weld joint compared to the natural cooling. The width of heat affected zone was reduced by the use of water cooling during friction stir welding (FSW) and minimum hardness zone was shifted towards weld center. The corrosion test was performed in 3.5% NaCl solution. Corrosion resistance of water cooled joint was found higher than natural cooled FSW joint. The precipitation behavior of weld nugget and heat affected zone impacts the corrosion resistance of FSW joint of AA 2014. Hardness, tensile, and corrosion properties of FSW joints produced under NC and WC conditions have been discussed in the light of microstructure.

  1. Joint Electromagnetic Spectrum Management Operations

    Science.gov (United States)

    2012-03-20

    promulgate command-specific policy and guidance for EMS use, the joint restricted frequency list (JRFL) process, the joint communications–electronics...joint communications–electronics operating instructions (JCEOI) and joint restricted frequency list (JRFL). Examples of FM include providing the...joint restricted frequency list Figure III-4. Joint Frequency Management Office Spectrum Management Process Chapter III III-10 JP 6-01 assignments

  2. A Study of Joint Cost Inclusion in Linear Programming Optimization

    Directory of Open Access Journals (Sweden)

    P. Armaos

    2013-08-01

    Full Text Available The concept of Structural Optimization has been a topic or research over the past century. Linear Programming Optimization has proved being the most reliable method of structural optimization. Global advances in linear programming optimization have been recently powered by University of Sheffield researchers, to include joint cost, self-weight and buckling considerations. A joint cost inclusion scopes to reduce the number of joints existing in an optimized structural solution, transforming it to a practically viable solution. The topic of the current paper is to investigate the effects of joint cost inclusion, as this is currently implemented in the optimization code. An extended literature review on this subject was conducted prior to familiarization with small scale optimization software. Using IntelliFORM software, a structured series of problems were set and analyzed. The joint cost tests examined benchmark problems and their consequent changes in the member topology, as the design domain was expanding. The findings of the analyses were remarkable and are being commented further on. The distinct topologies of solutions created by optimization processes are also recognized. Finally an alternative strategy of penalizing joints is presented.

  3. Structural geology report: Spent Fuel Test - Climax Nevada Test Site

    International Nuclear Information System (INIS)

    Wilder, D.G.; Yow, J.L. Jr.

    1984-10-01

    We performed underground mapping and core logging in the Climax Stock, a granitic intrusive at the Nevada Test Site, as part of a major field test to determine the feasibility of using granitic or crystalline rock for the underground storage of spent fuel from a nuclear reactor. This mapping and logging identified more than 2500 fractures, over 1500 of which were described in enough detail to allow statistical analyses and orientation studies to be performed. We identified eight joint sets, three major shear sets, and a fault zone within the Spent Fuel Test - Climax (SFT-C) portion of the Stock. Joint sets identified within the SFT-C and elsewhere in the Stock correlated well. The orientations of joint sets identified by other investigators were consistent with our findings, indicating that the joint sets are persistent and have a relatively uniform orientation throughout a major portion of the Stock. The one joint set not seen elsewhere in the Stock is healed and the wall rock is altered, implying that healed joints were not included in the mapping criteria used by other investigators. The shear sets were distinguished from the joint sets by virtue of crushed minerals, continuous clay infilling, and other evidences of shearing, and from faults by the lack of offsetting. Previous investigators working mainly in the Pile Driver Drifts identified two of the shear sets. The third set, being nearly parallel to these Drifts had not been identified previously. The fault zone identified at the far (Receiving Room) end of the project is oriented approximately N45 0 E-75 0 SE, similar to both the Boundary and Shaft Station Faults. We have, therefore, concluded that the Receiving Room Fault is one of a series of normal faults that occur within the Climax Stock and that are possibly related, in both age and genesis, to the Boundary Fault. 52 refs., 26 figs., 11 tabs

  4. Joint surface modeling with thin-plate splines.

    Science.gov (United States)

    Boyd, S K; Ronsky, J L; Lichti, D D; Salkauskas, K; Chapman, M A; Salkauskas, D

    1999-10-01

    Mathematical joint surface models based on experimentally determined data points can be used to investigate joint characteristics such as curvature, congruency, cartilage thickness, joint contact areas, as well as to provide geometric information well suited for finite element analysis. Commonly, surface modeling methods are based on B-splines, which involve tensor products. These methods have had success; however, they are limited due to the complex organizational aspect of working with surface patches, and modeling unordered, scattered experimental data points. An alternative method for mathematical joint surface modeling is presented based on the thin-plate spline (TPS). It has the advantage that it does not involve surface patches, and can model scattered data points without experimental data preparation. An analytical surface was developed and modeled with the TPS to quantify its interpolating and smoothing characteristics. Some limitations of the TPS include discontinuity of curvature at exactly the experimental surface data points, and numerical problems dealing with data sets in excess of 2000 points. However, suggestions for overcoming these limitations are presented. Testing the TPS with real experimental data, the patellofemoral joint of a cat was measured with multistation digital photogrammetry and modeled using the TPS to determine cartilage thicknesses and surface curvature. The cartilage thickness distribution ranged between 100 to 550 microns on the patella, and 100 to 300 microns on the femur. It was found that the TPS was an effective tool for modeling joint surfaces because no preparation of the experimental data points was necessary, and the resulting unique function representing the entire surface does not involve surface patches. A detailed algorithm is presented for implementation of the TPS.

  5. The Effect of Gap Angle on Tensile Strength of Preceramic Base Metal Solder Joints.

    Science.gov (United States)

    Fattahi, Farnaz; Hashemi Ardakani, Zahra; Hashemi Ardakani, Maryam

    2015-12-01

    Soldering is a process commonly used in fabricating dental prosthesis. Since most soldered prosthesis fail at the solder joints; the joint strength is of utmost importance. The purpose of this study was to evaluate the effect of gap angle on the tensile strength of base metal solder joints. A total number of 40 Ni-Cr samples were fabricated according to ADA/ISO 9693 specifications for tensile test. Samples were cut at the midpoint of the bar, and were placed at the considered angles by employing an explicitly designed device. They were divided into 4 groups regarding the gap angle; Group C (control group) with parallel gap on steady distance of 0.2mm, Group 1: 10°, Group 2: 20°, and Group3: 30° gap angles. When soldered, the specimens were all tested for tensile strength using a universal testing machine at a cross-head speed of 0.5 mm/min with a preload of 10N. Kruskal-Wallis H test was used to compare tensile strength among the groups (ptensile strength values obtained from the study groups were respectively 307.84, 391.50, 365.18, and 368.86 MPa. The tensile strength was not statistically different among the four groups in general (p≤ 0.490). Making the gap angular at the solder joints and the subsequent unsteady increase of the gap distance would not change the tensile strength of the joint.

  6. Designing aluminium friction stir welded joints against multiaxial fatigue

    Directory of Open Access Journals (Sweden)

    L. Susmel

    2016-07-01

    Full Text Available The present paper investigates the accuracy of the Modified Wöhler Curve Method (MWCM in estimating multiaxial fatigue strength of aluminium friction stir (FS welded joints. Having developed a bespoke joining technology, circumferentially FS welded tubular specimens of Al 6082-T6 were tested under proportional and non-proportional tension and torsion, the effect of non-zero mean stresses being also investigated. The validation exercise carried out using the experimental results have demonstrated that the MWCM applied in terms of nominal stresses, notch stresses, and also the Point Method is accurate in predicting the fatigue lifetime of the tested FS welded joints, with its use resulting in life estimates that fall within the uniaxial and torsional calibration scatter bands.

  7. Leak tight sealants and joint details for concrete structure in RAPP

    International Nuclear Information System (INIS)

    Singha Roy, P.K.; Baste, M.S.

    1975-01-01

    Leak tightness may pertain to either air or water and in extreme cases each will require separate consideration based on general basic requirements. Leak-tight sealants against air pressure are required in the construction joints and around penetrations in the concrete containment structures. The containment structures should be able to withstand the maximum anticipated design pressure during the incident of a MCA with only minimal leakage (0.1% of bldg. volume per day in RAPP) which is mostly through these joints. Apart from proper joint design and preparation the sealant itself must have superb adhesion to the concrete surface and integrify throughout its service life to prevent any rupture or micro-cracks at any section of the joint. Leak tightness pertains to water tightness as well. A critical water-tight joint at the bottom dome of the prestressed concrete dousing tank at its junction with the 36 inches dia dousing water pipes constructed in RAPP-2, which should be able to withstand the water pressure, continuous submergence in the water of the tank and the longitudinal and lateral movement of the water pipes during opening and closure of the dousing valves, has been made and hydrostatically tested when not even the slight sweating was found. The construction and materials of the above joints and the sealant along with the properties and performance observed during testing/use are described. As the sealant used is an imported poly-sulphide caulking compound suggestions have also been made, which may be kept in mind while developing an Indian substitute. (author)

  8. Microstructure and mechanical properties of resistance upset butt welded 304 austenitic stainless steel joints

    International Nuclear Information System (INIS)

    Sharifitabar, M.; Halvaee, A.; Khorshahian, S.

    2011-01-01

    Graphical abstract: Three different microstructural zones formed at different distances from the joint interface in resistance upset butt welding of 304 austenitic stainless steel. Highlights: → Evaluation of microstructure in resistance upset welding of 304 stainless steel. → Evaluation of welding parameters effects on mechanical properties of the joint. → Introducing the optimum welding condition for joining stainless steel bars. -- Abstract: Resistance upset welding (UW) is a widely used process for joining metal parts. In this process, current, time and upset pressure are three parameters that affect the quality of welded products. In the present research, resistance upset butt welding of 304 austenitic stainless steel and effect of welding power and upset pressure on microstructure, tensile strength and fatigue life of the joint were investigated. Microstructure of welds were studied using scanning electron microscopy (SEM). X-ray diffraction (XRD) analysis was used to distinguish the phase(s) that formed at the joint interface and in heat affected zone (HAZ). Energy dispersive spectroscopy (EDS) linked to the SEM was used to determine chemical composition of phases formed at the joint interface. Fatigue tests were performed using a pull-push fatigue test machine and the fatigue properties were analyzed drawing stress-number of cycles to failure (S-N) curves. Also tensile strength tests were performed. Finally tensile and fatigue fracture surfaces were studied by SEM. Results showed that there were three different microstructural zones at different distances from the joint interface and delta ferrite phase has formed in these regions. There was no precipitation of chromium carbide at the joint interface and in the HAZ. Tensile and fatigue strengths of the joint decreased with welding power. Increasing of upset pressure has also considerable influence on tensile strength of the joint. Fractography of fractured samples showed that formation of hot spots at

  9. Integration test of ITER full-scale vacuum vessel sector

    International Nuclear Information System (INIS)

    Nakahira, M.; Koizumi, K.; Oka, K.

    2001-01-01

    The full-scale Sector Model Project, which was initiated in 1995 as one of the Large Seven R and D Projects, completed all R and D activities planned in the ITER-EDA period with the joint effort of the ITER Joint Central Team (JCT), the Japanese, the Russian Federation (RF) and the United States (US) Home Teams. The fabrication of a full-scale 18 toroidal sector, which is composed of two 9 sectors spliced at the port center, was successfully completed in September 1997 with the dimensional accuracy of ± 3 mm for the total height and total width. Both sectors were shipped to the test site in JAERI and the integration test was begun in October 1997. The integration test involves the adjustment of field joints, automatic Narrow Gap Tungsten Inert Gas (NG-TIG) welding of field joints with splice plates, and inspection of the joint by ultrasonic testing (UT), which are required for the initial assembly of ITER vacuum vessel. This first demonstration of field joint welding and performance test on the mechanical characteristics were completed in May 1998 and the all results obtained have satisfied the ITER design. In addition to these tests, the integration with the mid plane port extension fabricated by the Russian Home Team, and the cutting and re-welding test of field joints by using full-remotized welding and cutting system developed by the US Home Team, are planned as post EDA activities. (author)

  10. Integration test of ITER full-scale vacuum vessel sector

    International Nuclear Information System (INIS)

    Nakahira, M.; Koizumi, K.; Oka, K.

    1999-01-01

    The full-scale Sector Model Project, which was initiated in 1995 as one of the Large Seven ITER R and D Projects, completed all R and D activities planned in the ITER-EDA period with the joint effort of the ITER Joint Central Team (JCT), the Japanese, the Russian Federation (RF) and the United States (US) Home Teams. The fabrication of a full-scale 18 toroidal sector, which is composed of two 9 sectors spliced at the port center, was successfully completed in September 1997 with the dimensional accuracy of - 3 mm for the total height and total width. Both sectors were shipped to the test site in JAERI and the integration test was begun in October 1997. The integration test involves the adjustment of field joints, automatic Narrow Gap Tungsten Inert Gas (NG-TIG) welding of field joints with splice plates, and inspection of the joint by ultrasonic testing (UT), which are required for the initial assembly of ITER vacuum vessel. This first demonstration of field joint welding and performance test on the mechanical characteristics were completed in May 1998 and the all results obtained have satisfied the ITER design. In addition to these tests, the integration with the mid plane port extension fabricated by the Russian Home Team, and the cutting and re-welding test of field joints by using full-remotized welding and cutting system developed by the US Home Team, are planned as post EDA activities. (author)

  11. Recent Advances in Computational Mechanics of the Human Knee Joint

    Science.gov (United States)

    Kazemi, M.; Dabiri, Y.; Li, L. P.

    2013-01-01

    Computational mechanics has been advanced in every area of orthopedic biomechanics. The objective of this paper is to provide a general review of the computational models used in the analysis of the mechanical function of the knee joint in different loading and pathological conditions. Major review articles published in related areas are summarized first. The constitutive models for soft tissues of the knee are briefly discussed to facilitate understanding the joint modeling. A detailed review of the tibiofemoral joint models is presented thereafter. The geometry reconstruction procedures as well as some critical issues in finite element modeling are also discussed. Computational modeling can be a reliable and effective method for the study of mechanical behavior of the knee joint, if the model is constructed correctly. Single-phase material models have been used to predict the instantaneous load response for the healthy knees and repaired joints, such as total and partial meniscectomies, ACL and PCL reconstructions, and joint replacements. Recently, poromechanical models accounting for fluid pressurization in soft tissues have been proposed to study the viscoelastic response of the healthy and impaired knee joints. While the constitutive modeling has been considerably advanced at the tissue level, many challenges still exist in applying a good material model to three-dimensional joint simulations. A complete model validation at the joint level seems impossible presently, because only simple data can be obtained experimentally. Therefore, model validation may be concentrated on the constitutive laws using multiple mechanical tests of the tissues. Extensive model verifications at the joint level are still crucial for the accuracy of the modeling. PMID:23509602

  12. Criterion Validation Testing of Clinical Metrology Instruments for Measuring Degenerative Joint Disease Associated Mobility Impairment in Cats.

    Science.gov (United States)

    Gruen, Margaret E; Griffith, Emily H; Thomson, Andrea E; Simpson, Wendy; Lascelles, B Duncan X

    2015-01-01

    Degenerative joint disease and associated pain are common in cats, particularly in older cats. There is a need for treatment options, however evaluation of putative therapies is limited by a lack of suitable, validated outcome measures that can be used in the target population of client owned cats. The objectives of this study were to evaluate low-dose daily meloxicam for the treatment of pain associated with degenerative joint disease in cats, and further validate two clinical metrology instruments, the Feline Musculoskeletal Pain Index (FMPI) and the Client Specific Outcome Measures (CSOM). Sixty-six client owned cats with degenerative joint disease and owner-reported impairments in mobility were screened and enrolled into a double-masked, placebo-controlled, randomized clinical trial. Following a run-in baseline period, cats were given either placebo or meloxicam for 21 days, then in a masked washout, cats were all given placebo for 21 days. Subsequently, cats were given the opposite treatment, placebo or meloxicam, for 21 days. Cats wore activity monitors throughout the study, owners completed clinical metrology instruments following each period. Activity counts were increased in cats during treatment with daily meloxicam (pdegenerative joint disease.

  13. Imaging findings of charcot joint

    International Nuclear Information System (INIS)

    Meng Quanfei; Zhou Chunxiang; Chen Yingming; Jiang Bo

    2003-01-01

    Objective: To analyze the MRI characters of Charcot joint, and to evaluate the diagnostic value of X-ray, CT, and MRI on Charcot joint. Methods: Eight patients with 8 Charcot joints underwent X-ray, CT, and MR examinations. 6 of them had syringomyelia, 1 patient had injury of the spinal cord, and 1 case had diabetes. All 8 patients had sensory reduction or deficit in the sick extremities. Results: There were two types of Charcot joint, hypertrophic and atrophic. Radiographic and CT features of hypertrophic joint (n=3) showed hyperostotic osteosclerosis and mammoth osteophytes in the sick bones, periarticular ossification, and articular disorganization. Radiographic and CT features of atrophic joint (n=5) showed extensive bone resorption (destruction), periarticular debris, and articular disorganization. Main MRI features of Charcot joint included hydrarthrosis within joint capsule, thickened, loose, and elongated joint capsule with para-joint, peri-diaphysis, and inter-muscular extension in a pseudopodia pattern. The irregular joint capsule wall was presented as mild hypointensity on T 1 WI, slight hyper-intensity on T 2 WI, and was markedly enhanced after Gd-DTPA was administrated, which was considered as a characteristic manifestation of the lesion. Soft tissue mass containing hypo-intense stripes on both T 1 WI and T 2 WI was commonly noted adjacent to the involved joint. Conclusion: X-rays plain film is the first choice for the diagnosis of Charcot joint, and MRI is pretty useful in the diagnosis of Charcot joint

  14. EFFICACY OF ADDUCTOR PULL BACK EXERCISE ON PAIN AND FUNCTIONAL DISABILITY FOR SACROILIAC JOINT DYSFUNCTION

    Directory of Open Access Journals (Sweden)

    Sai Kumar .N

    2015-08-01

    Full Text Available Background: Sacroiliac joint dysfunction (SIJD is a common problem that causes pain and disability. Adductor pull back exercise is widely used for treating sacroiliac joint dysfunction. No yet research has been directly examined the efficacy of adductor pull back exercise for sacroiliac joint dysfunction. The purpose of the study to find the efficacy of adductor pull back exercise on pain and functional disability for subjects with sacroiliac joint dysfunction. Methods: An experimental study design, 40 subjects with unilateral Sacroiliac joint dysfunction were randomized into two groups: study group (n=20, and control group (n=20. Subjects in study group received adductor pull back exercise along with conventional exercise and Subjects in control group received conventional exercise. The duration of treatment was given for two weeks, three times a day, total six days per week. Outcome measures such as pain was measured using Visual analog scale (VAS, and functional disability was measured using Oswestry Disability Index questionnaire (ODI before and after 2 weeks of the treatment in both the groups. Results: When means were analyzed using Independent ‘t’ test as a parametric and Mann Whitney U test as a non-parametric test, there is a statistically significant improvements in means of VAS, and ODI within the groups. When means were compared using Independent ‘t’ and Mann Whitney U test, there is a significant difference in post-means of VAS and ODI between the groups. Conclusion: The present study concludes that the 2 weeks of adductor pull back exercise along with conventional exercise found statistically and clinically significant effect on improving pain, functional disability for subjects with sacroiliac joint dysfunction. Adductors pull back exercise along with conventional exercise techniques shown to have greater percentage of improvement in improving pain and functional disability for subjects with sacroiliac joint dysfunction.

  15. Biochemical and biomechanical characterisation of equine cervical facet joint cartilage.

    Science.gov (United States)

    O'Leary, S A; White, J L; Hu, J C; Athanasiou, K A

    2018-04-15

    The equine cervical facet joint is a site of significant pathology. Located bilaterally on the dorsal spine, these diarthrodial joints work in conjunction with the intervertebral disc to facilitate appropriate spinal motion. Despite the high prevalence of pathology in this joint, the facet joint is understudied and thus lacking in viable treatment options. The goal of this study was to characterise equine facet joint cartilage and provide a comprehensive database describing the morphological, histological, biochemical and biomechanical properties of this tissue. Descriptive cadaver studies. A total of 132 facet joint surfaces were harvested from the cervical spines of six skeletally mature horses (11 surfaces per animal) for compiling biomechanical and biochemical properties of hyaline cartilage of the equine cervical facet joints. Gross morphometric measurements and histological staining were performed on facet joint cartilage. Creep indentation and uniaxial strain-to-failure testing were used to determine the biomechanical compressive and tensile properties. Biochemical assays included quantification of total collagen, sulfated glycosaminoglycan and DNA content. The facet joint surfaces were ovoid in shape with a flat articular surface. Histological analyses highlighted structures akin to articular cartilage of other synovial joints. In general, biomechanical and biochemical properties did not differ significantly between the inferior and superior joint surfaces as well as among spinal levels. Interestingly, compressive and tensile properties of cervical facet articular cartilage were lower than those of articular cartilage from other previously characterised equine joints. Removal of the superficial zone reduced the tissue's tensile strength, suggesting that this zone is important for the tensile integrity of the tissue. Facet surfaces were sampled at a single, central location and do not capture the potential topographic variation in cartilage properties. This

  16. Formed electroslag welded joint from austenitic steel 18/10 CrNi

    International Nuclear Information System (INIS)

    Jilek, L.; Kusak, L.; Martinak, A.

    1987-01-01

    The electroslag welded joint from titanium stabilized steel 18/10 CrNi of 150 mm in thickness showed positive results for both nondestructive and destructive testing. Czechoslovak flux VUZ-4F and the optimized welding mode were completely proven. The weldment was subject to deformation by forging with a removal of 20 to 50% and to bending deformation. A 40% to 50% deformation was necessary for breaking the coarse-grain casting structure. The bending deformation resulted in breaking the coarse-grain casting structure in the entire cross-section, it was, however, only acting in a narrow band corresponding to the largest curvature. At the same time, the heat affected zone decayed. Following heat treatment, especially forming, the delta ferrite content in the weld metal decreased, the mechanical properties of the weld metal and the welded joint following welding and heat treatment showed a relatively large scatter. Forming reduced the scatter and improved plastic properties. Machining within 40 and 50% resulted in good echogenicity of the welded joint in ultrasound testing. The welded joint showed equal properties as the base material of the weldment. (author). 15 figs., 2 tabs., 16 refs

  17. Longitudinally Jointed Edge-wise Compression Honeycomb Composite Sandwich Coupon Testing and FE Analysis: Three Methods of Strain Measurement, and Comparison

    Science.gov (United States)

    Farrokh, Babak; AbdulRahim, Nur Aida; Segal, Ken; Fan, Terry; Jones, Justin; Hodges, Ken; Mashni, Noah; Garg, Naman; Sang, Alex; Gifford, Dawn; hide

    2013-01-01

    Three means (i.e., typical foil strain gages, fiber optic sensors, and a digital image correlation (DIC) system) were implemented to measure strains on the back and front surfaces of a longitudinally jointed curved test article subjected to edge-wise compression testing, at NASA Goddard Space Flight Center, according to ASTM C364. The Pre-test finite element analysis (FEA) was conducted to assess ultimate failure load and predict strain distribution pattern throughout the test coupon. The predicted strain pattern contours were then utilized as guidelines for installing the strain measurement instrumentations. The strain gages and fiber optic sensors were bonded on the specimen at locations with nearly the same strain values, as close as possible to each other, so that, comparisons between the measured strains by strain gages and fiber optic sensors, as well as the DIC system are justified. The test article was loaded to failure (at approximately 38 kips), at the strain value of approximately 10,000mu epsilon As a part of this study, the validity of the measured strains by fiber optic sensors is examined against the strain gage and DIC data, and also will be compared with FEA predictions.

  18. A contribution of quality assurance in veterinary radiography: further development and calibration of a test phantom to control the radiographic quality of X-rays of the equine hock joint

    International Nuclear Information System (INIS)

    Grohmann, D.

    1996-10-01

    The test phantom, which was elaborated by PARISOT (1988), was further developed and calibrated for the equine hock joint. As bigger bone layers had to be radiated, in comparison with the already existing calibration, a new material with higher radiographic density was used for the construction of a new test phantom. A copper test phantom, constructed like a staircase, containing drill-holes in the bottom plate, was used. This practical test phantom, on the highest step only 2.3 mm thick, should prove to be small enough to suit to the daily use in the equine practice. The photographs of each of the views were judged by a specialist in equine medicine and classified into three groups with the criteria 'too light', 'good' and 'too dark'. Then 15 test subjects determined the upper limit of the visibility of the two drillings. After statistical analysis of the data, standard ranges for the three photographing directions were fixed and nomograms were made. As a result of simultaneous photographing of the test phantom and the hock joint of interest, the observer is able to assess the quality of the radiograph. Determining the upper limit of visibility of the holes in the staircase, he can judge the photograph as suitable, too light or too dark for diagnostic use. (author)

  19. Fatigue strength evaluation of friction stir welded aluminium joints using the nominal and notch stress concepts

    International Nuclear Information System (INIS)

    Barsoum, Z.; Khurshid, M.; Barsoum, I.

    2012-01-01

    Highlights: ► Fatigue testing and evaluation of friction stir welded butt and overlap joints. ► Evaluation based on nominal and effective notch stress concept. ► Comparison with different design recommendations and codes. ► Higher fatigue strength and SN-slopes is observed. ► New fatigue design recommendations proposed for FSW joints. -- Abstract: In this study the fatigue strength is investigated for Friction Stir Welded (FSW) overlap and butt welded joints in different thicknesses based on nominal and effective notch stress concepts. The fatigue test results are compared with fatigue strength recommendations according to EN 1999-1-3 and International Institute of Welding (IIW). The results are also compared with available published data and Finite Element Analysis (FEA) is carried out to investigate the effect of plate thickness and nugget size on the fatigue strength of overlap joints. 3–3 mm butt welded joints shows the highest fatigue strength in comparison with 3–5 mm butt welded and overlap joints. Slopes of the SN-curves for two different joint types differ from the slope recommended by IIW. A specific failure trend is observed in overlap FSW joints. However, the slopes of the SN-curves are in close agreement with slopes found in EN 1999-1-3. The slopes of various published results and test results presented in this study are in good agreement with each other. The suggested fatigue design curves for the nominal and effective notch stress concept have a higher slope than given for fusion welds by IIW.

  20. Matrix-assisted laser desorption ionization time of flight mass spectrometry and diagnostic testing for prosthetic joint infection in the clinical microbiology laboratory.

    Science.gov (United States)

    Peel, Trisha N; Cole, Nicolynn C; Dylla, Brenda L; Patel, Robin

    2015-03-01

    Identification of pathogen(s) associated with prosthetic joint infection (PJI) is critical for patient management. Historically, many laboratories have not routinely identified organisms such as coagulase-negative staphylococci to the species level. The advent of matrix-assisted laser desorption ionization time of flight mass spectrometry (MALDI-TOF MS) has enhanced clinical laboratory capacity for accurate species-level identification. The aim of this study was to describe the species-level identification of microorganisms isolated from periprosthetic tissue and fluid specimens using MALDI-TOF MS alongside other rapid identification tests in a clinical microbiology laboratory. Results of rapid identification of bacteria isolated from periprosthetic joint fluid and/or tissue specimens were correlated with clinical findings at Mayo Clinic, Rochester, Minnesota, between May 2012 and May 2013. There were 178 PJI and 82 aseptic failure (AF) cases analyzed, yielding 770 organisms (median, 3/subject; range, 1-19/subject). MALDI-TOF MS was employed for the identification of 455 organisms (59%) in 197 subjects (123 PJIs and 74 AFs), with 89% identified to the species level using this technique. Gram-positive bacteria accounted for 68% and 93% of isolates in PJI and AF, respectively. However, the profile of species associated with infection compared to specimen contamination differed. Staphylococcus aureus and Staphylococcus caprae were always associated with infection, Staphylococcus epidermidis and Staphylococcus lugdunensis were equally likely to be a pathogen or a contaminant, whereas the other coagulase-negative staphylococci were more frequently contaminants. Most streptococcal and Corynebacterium isolates were pathogens. The likelihood that an organism was a pathogen or contaminant differed with the prosthetic joint location, particularly in the case of Propionibacterium acnes. MALDI-TOF MS is a valuable tool for the identification of bacteria isolated from patients

  1. A study of fatigue life distribution of butt-welded joints

    International Nuclear Information System (INIS)

    Sakai, Tatsuo; Fujitani, Keizo; Kikuchi, Toshiro; Tanaka, Takao.

    1981-01-01

    Various kinds of welded joints are being used in many structures such as ships, bridges and constructions. It is important in reliability analysis of such structures to clarify the statistical fatigue property of the welded joints. In this study, fatigue tests were carried out on the butt-welded joints of SM50A steel and a theoretical interpretation on the fatigue life distribution was attempted, assuming that a butt-welded joint is composed of a number of sliced specimens with different fatigue strengths. Main results obtained are summarized as follows; (1) The median crack initiation life of the butt-welded joint specimens coincided with that of the sliced specimens, when the crack initiation was defined by a 0.2 mm crack in the sliced specimens or the equivalent state of stress intensity factor in the joint specimens. (2) The distribution of crack initiation lives of the butt-welded joints can be theoretically derived by combining the concept of extreme distribution and the distribution model on the number of fatigue cracks. The theoretical distribution of crack initiation lives of the joints is in good agreement with the general trend of the experimental results. (3) If the distribution of crack initiation lives and the crack growth law are given experimentally, one can obtain analytically the distribution of final fatigue lives. The fatigue life distribution of the sliced specimens can be explained by the theory established in this study. (author)

  2. A new bootstrap test for multiple assets joint risk testing

    NARCIS (Netherlands)

    Ardia, David; Gatarek, Lukasz; Hoogerheide, Lennart F.

    2017-01-01

    In this paper, a novel simulation-based methodology is proposed to test the validity of a set of marginal time series models, where the dependence structure between the time series is taken directly from the observed data. The procedure is useful when one wants to summarize the test results for

  3. Nuclear medicine and the failed joint replacement: Past, present, and future.

    Science.gov (United States)

    Palestro, Christopher J

    2014-07-28

    Soon after the introduction of the modern prosthetic joint, it was recognized that radionuclide imaging provides useful information about these devices. The bone scan was used extensively to identify causes of prosthetic joint failure. It became apparent, however, that although sensitive, regardless of how the images were analyzed or how it was performed, the test was not specific and could not distinguish among the causes of prosthetic failure. Advances in anatomic imaging, notably cross sectional modalities, have facilitated the diagnosis of many, if not most, causes of prosthetic failure, with the important exception of infection. This has led to a shift in the diagnostic paradigm, in which nuclear medicine investigations increasingly have focused on diagnosing infection. The recognition that bone scintigraphy could not reliably diagnose infection led to the development of combined studies, first bone/gallium and subsequently leukocyte/bone and leukocyte/marrow imaging. Labeled leukocyte imaging, combined with bone marrow imaging is the most accurate (about 90%) imaging test for diagnosing joint arthroplasty infection. Its value not withstanding, there are significant disadvantages to this test. In-vivo techniques for labeling leukocytes, using antigranulocyte antibodies have been explored, but have their own limitations and the results have been inconsistent. Fluorodeoxyglucose (FDG)-positron emission tomography (FDG-PET) has been extensively investigated for more than a decade but its role in diagnosing the infected prosthesis has yet to be established. Antimicrobial peptides bind to bacterial cell membranes and are infection specific. Data suggest that these agents may be useful for diagnosing prosthetic joint infection, but large scale studies have yet to be undertaken. Although for many years nuclear medicine has focused on diagnosing prosthetic joint infection, the advent of hybrid imaging with single-photon emission computed tomography

  4. Formation of tough composite joints

    International Nuclear Information System (INIS)

    Brun, M.K.

    1997-05-01

    Joints which exhibit tough fracture behavior were formed in a composite with a Si/SiC matrix reinforced with Textron SCS-6 fibers with either boron nitride or silicon nitride fiber coatings. In composites with BN coatings fibers were aligned uniaxially, while composites with Si 3 N 4 -coated fibers had a 0/90 degree architecture. Lapped joints (joints with overlapping fingers) were necessary to obtain tough behavior. Geometrical requirements necessary to avoid brittle joint failure have been proposed. Joints with a simple overlap geometry (only a few fingers) would have to be very long in order to prevent brittle failure. Typical failure in these joints is caused by a crack propagating along the interfaces between the joint fingers. Joints of the same overall length, but with geometry changed to be symmetric about the joint centerline and with an extra shear surface exhibited tough fractures accompanied with extensive fiber pullout. The initial matrix cracking of these joints was relatively low because cracks propagated easily through the ends of the fingers. Joints with an optimized stepped sawtooth geometry produced composite-like failures with the stress/strain curves containing an elastic region followed by a region of rising stress with an increase of strain. Increasing the fiber/matrix interfacial strength from 9 to 25 MPa, by changing the fiber coating, increased matrix cracking and ultimate strength of the composite significantly. The best joints had matrix cracking stress and ultimate strength of 138 and 240 MPa, respectively. Joint failure was preceded by multiple matrix cracking in the entire composite. The high strength of the joints will permit building of structures containing joints with only a minor reduction of design stresses

  5. Research on Microstructure and Properties of Welded Joint of High Strength Steel

    Science.gov (United States)

    Zhu, Pengxiao; Li, Yi; Chen, Bo; Ma, Xuejiao; Zhang, Dongya; Tang, Cai

    2018-01-01

    BS960 steel plates were welded by Laser-MAG and MAG. The microstructure and properties of the welded joints were investigated by optical microscope, micro-hardness tester, universal tensile testing machine, impact tester, scanning electron microscope (SEM) and fatigue tester. By a series of experiments, the following results were obtained: The grain size of the coarse grain zone with Laser-MAG welded joint is 20μm, and that with MAG welded joint is about 32μm, both of the fine grain region are composed of fine lath martensite and granular bainite; the width of the heat affected region with Laser-MAG is lower than that with MAG. The strength and impact energy of welded joints with Laser-MAG is higher than that with MAG. The conditioned fatigue limit of welded joint with Laser-MAG is 280MPa; however, the conditioned fatigue limit of welded joint with MAG is 250MPa.

  6. A comparison of clinical symptoms and magnetic resonance images in temporomandibular joint disorders

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yong Suk; Hwang, Eui Hwan; Lee, Sang Rae [Kyunghee University College of Medicine, Seoul (Korea, Republic of)

    2003-06-15

    To determine the relationship between clinical symptoms and magnetic resonance (MR) images in patients presenting with temporomandibular joint (TMJ) disorders. This study was based on 172 joints in 86 patients presenting with TMJ disorders. Joint pain and sound during jaw opening and closing movements were recorded, and the possible relationship between disc positions and bony changes of the condylar head and the articular fossa in MR images in the oblique sagittal planes were examined. Data were analyzed by Chi-square test. There was no statistically significant relationship between clinical symptoms and MR images in the patients with TMJ disorders. In the patient with TMJ disorders, joint pain and sound could not be specific clinical symptoms that are related with MR image findings, and asymptomatic joint did not necessarily imply that the joints are normal according to MR image findings.

  7. Quality Analysis of Welded and Soldered Joints of Cu-Nb Microcomposite Wires

    Directory of Open Access Journals (Sweden)

    Nikolaj VIŠNIAKOV

    2011-03-01

    Full Text Available Quality analysis of welded and soldered joints of Cu-Nb microcomposite wires has been performed. Quality and mechanical characteristics of joints as ultimate tensile stress limit and elongation at break were measured with an universal testing machine and controlled visually using an optical microscope. Two wires joints were soldered with silver and copper solders and put into steel and copper sleeve respectively. Another two wires joints were soldered with silver solder and welded without any reinforcement. Joints soldered with the silver solder and steel sleeve have demonstrated the best mechanical characteristics: ultimate tensile stress limit of 650 MPa and elongation at break of 0.85 %. Joints soldered with the copper sleeve have no advantages comparing with the soldered butt joint. Ultimate tensile stress limit and elongation at break were in 300 MPa - 350 MPa and in 0.35 % - 0.45 % ranges respectively. Two welded joints had ultimate tensile stress limit of 470 MPa and elongation at break of 0.71 %. In all joints the microstructure of Nb filaments was destroyed and mechanical properties have been specified by mechanical strength of copper and sleeve materials only.http://dx.doi.org/10.5755/j01.ms.17.1.242

  8. Transition temperature of embrittlement of steel 11 474.1 welded joint

    International Nuclear Information System (INIS)

    Petrikova, A.; Cocher, M.

    1987-01-01

    The results are presented of tests of notch toughness in dependence on temperature for steel 11 474.1 used for the manufacture of steam separators, in the area of a joint welded using an automatic submerged-arc welding machine with pre-heating at 200 to 250 degC. After welding, the welded joints were annealed for reduced stress for 160 minutes at a temperature of 600 to 650 degC and left to cool off in the furnace. The obtained results show that: (1) critical embrittlement temperature for the welded joint and the given welding technology ranges within -20 and -13 degC; (2) critical embrittlement temperature following heat ageing is shifted to positive temperature values; (3) pressure tests of the steam separator jacket made of steel 11 474.1 may in the process of production be carried out at a minimal wall temperature of 17 degC; (4) in case a pressure test has to be made after the equipment has been in operation for a certain period of time the test will probably have to be made at temperatures higher than 20 degC; (5) further tests will have to be made at temperatures higher than 20 degC in order to determine critical embrittlement temperatures after ageing. (J.B.). 7 figs., 2 tabs., 5 refs

  9. Relation between sensitization and failures of welded joints at furnaces of Cienfuegos refinery

    International Nuclear Information System (INIS)

    Dominguez, H.; Menendez, C.M.; Sendoya, F.A.

    1992-01-01

    This work is concerned about the possible relation between sensitization and failures of welded joints at furnaces of Cienfuegos Refinery. This failures were detected in austenitic pipes by hydraulic testing. For determined the tendency to sensitization of heat affected zones (HAZ) of welded joints and piping, have been used standardized test methods AM and AMU (GOST 6032-89). In addition, the Electrochemical Potentiokinetic Reactivation (EPR) test was employed to quantity the tendency to intergranular corrosion. It was found that degree of sensitization was higher at HAZ and as a possible explanation is proposed the overheating during welding

  10. Metallographic anlaysis and strength investigation of different Be-Cu joints in the temperature range RT-3500C

    International Nuclear Information System (INIS)

    Gervash, A.A.; Giniatouline, R.N.; Mazul, I.V.

    1995-01-01

    The goal of this work is to estimate the strength and structure of different Be-Cu joining techniques. Brazing, diffusion bonding and joint rolling methods were chosen as ITER Be-Cu joint method candidates. Selected for ITER application Be-Cu joints were produced as technological plates (30-50 mm x 50-100 mm x thickness). AR samples for farther investigations were cutted out from initial technological plates. To compare mechanical strength of selected Be-Cu joints tensile and shearing tests of chosen candidates were carried out in the temperature range RT - 350 degrees C. The metallographic analysis of Be-Cu crosssection was also done. Preliminary results of these tests as well as metallographic analysis data are presented. The industrial possibilities of producing required for ITER full scale Be-Cu joints are discussed

  11. Welded joint properties of steel 2.25Cr1MoNiNb

    International Nuclear Information System (INIS)

    Gladis, R.; Ivanek, J.; Gottwald, M.

    1981-01-01

    Welded joints of steel 08Cr2.25Mo1NiNb for fast reactor steam generators made using manual arc welding with electrodes of identical compositions attain short-term mechanical properties and times to fracture when creep tested that match those of the base material. The reduction of the carbidic phase content in the steel and the welded joint metal did not adversely affect the tensile properties of the welded joint while increasing notch toughness of the heat-affected zone. Reduced carbon and niobium contents in the steel and the welded joint resulted in significant reduction in the proportion of carbidic eutectic particles in both the heat-affected zone and the weld metal. (Ha)

  12. Fatigue behavior of thick composite single lap joints

    Energy Technology Data Exchange (ETDEWEB)

    Tang, J.H.; Sridhar, I.; Srikanth, N. [Nanyang Technological Univ., Singapore (Singapore)

    2012-07-01

    In consideration of bondline thickness variability, in bonded joints where thick adherend is adopted, relative thick adhesive layer (2-5 mm) is preferable. This paper aims to give some insight in fatigue strength of adhesively bonded structures involving thick adherend coupled with thick adhesive layer. Single lap joints with nominal adherend thickness of 8 mm and two different nominal thicknesses (2.5 mm and 5.5 mm) were made and tested under fatigue loading. The failure mode exhibits always a tendency for interfacial initiation, followed by interlaminar separation. Fatigue strength for higher adhesive thickness is found to be lower. (Author)

  13. Tribology and total hip joint replacement: current concepts in mechanical simulation.

    Science.gov (United States)

    Affatato, S; Spinelli, M; Zavalloni, M; Mazzega-Fabbro, C; Viceconti, M

    2008-12-01

    Interest in the rheology and effects of interacting surfaces is as ancient as man. This subject can be represented by a recently coined word: tribology. This term is derived from the Greek word "tribos" and means the "science of rubbing". Friction, lubrication, and wear mechanism in the common English language means the precise field of interest of tribology. Wear of total hip prosthesis is a significant clinical problem that involves, nowadays, a too high a number of patients. In order to acquire further knowledge on the tribological phenomena that involve hip prosthesis wear tests are conducted on employed materials to extend lifetime of orthopaedic implants. The most basic type of test device is the material wear machine, however, a more advanced one may more accurately reproduce some of the in vivo conditions. Typically, these apparatus are called simulators, and, while there is no absolute definition of a joint simulator, its description as a mechanical rig used to test a joint replacement, under conditions approximating those occurring in the human body, is acceptable. Simulator tests, moreover, can be used to conduct accelerated protocols that replicate/simulate particularly extreme conditions, thus establishing the limits of performance for the material. Simulators vary in their level of sophistication and the international literature reveals many interpretations of the design of machines used for joint replacement testing. This paper aims to review the current state of the art of the hip joint simulators worldwide. This is specified through a schematic overview by describing, in particular, constructive solutions adopted to reproduce in vivo conditions. An exhaustive commentary on the evolution and actually existing simulation standards is proposed by the authors. The need of a shared protocol among research laboratories all over the world could lead to a consensus conference.

  14. Microstructure and mechanical properties of China low activation martensitic steel joint by TIG multi-pass welding with a new filler wire

    Science.gov (United States)

    Huang, Bo; Zhang, Junyu; Wu, Qingsheng

    2017-07-01

    Tungsten Inner Gas (TIG) welding is employed for joining of China low activation martensitic (CLAM) steel. A new filler wire was proposed, and the investigation on welding with various heat input and welding passes were conducted to lower the tendency towards the residual of δ ferrite in the joint. With the optimized welding parameters, a butt joint by multi-pass welding with the new filler wire was prepared to investigate the microstructure and mechanical properties. The microstructure of the joint was observed by optical microscope (OM) and scanning electron microscope (SEM). The hardness, Charpy impact and tensile tests of the joint were implemented at room temperature (25 °C). The results revealed that almost full martensite free from ferrite in the joints were obtained by multipass welding with the heat input of 2.26 kJ/mm. A certain degree of softening occurred at the heat affected zone of the joint according to the results of tensile and hardness tests. The as welded joints showed brittle fracture in the impact tests. However, the joints showed toughness fracture after tempering and relatively better comprehensive performance were achieved when the joints were tempered at 740 °C for 2 h.

  15. Disassembly Properties of Cementitious Finish Joints Using an Induction Heating Method

    Science.gov (United States)

    Ahn, Jaecheol; Noguchi, Takafumi; Kitagaki, Ryoma

    2015-01-01

    Efficient maintenance and upgrading of a building during its lifecycle are difficult because a cementitious finish uses materials and parts with low disassembly properties. Additionally, the reuse and recycling processes during building demolition also present numerous problems from the perspective of environmental technology. In this study, an induction heating (IH) method was used to disassemble cementitious finish joints, which are widely used to join building members and materials. The IH rapidly and selectively heated and weakened these joints. The temperature elevation characteristics of the cementitious joint materials were measured as a function of several resistor types, including wire meshes and punching metals, which are usually used for cementitious finishing. The disassembly properties were evaluated through various tests using conductive resistors in cementitious joints such as mortar. When steel fiber, punching metal, and wire mesh were used as conductive resistors, the cementitious modifiers could be weakened within 30 s. Cementitious joints with conductive resistors also showed complete disassembly with little residual bond strength.

  16. Microseismic monitoring of columnar jointed basalt fracture activity: a trial at the Baihetan Hydropower Station, China

    Science.gov (United States)

    Chen, Bing-Rui; Li, Qing-Peng; Feng, Xia-Ting; Xiao, Ya-Xun; Feng, Guang-Liang; Hu, Lian-Xing

    2014-10-01

    Severe stress release has occurred to the surrounding rocks of the typically columnar jointed basalt after excavation at the Baihetan Hydropower Station, Jinsha River, China, where cracking, collapse, and other types of failure may take place occasionally due to relaxation fracture. In order to understand the relaxation fracture characteristics of the columnar jointed basalt in the entire excavation process at the diversion tunnel of the Baihetan Hydropower Station, real-time microseismic monitoring tests were performed. First, the applicability of a geophone and accelerometer was analyzed in the columnar jointed basalt tunnel, and the results show that the accelerometer was more applicable to the cracking monitoring of the columnar jointed basalt. Next, the waveform characteristics of the microseismic signals were analyzed, and the microseismic signals were identified as follows: rock fracture signal, drilling signal, electrical signal, heavy vehicle passing signal, and blast signal. Then, the attenuation characteristics of the microseismic signals in the columnar jointed basalt tunnel were studied, as well as the types and characteristics of the columnar jointed basalt fracture. Finally, location analysis was conducted on the strong rock fracture events, in which four or more sensors were triggered, to obtain the temporal and spatial evolution characteristics and laws of the columnar jointed basalt relaxation fracture after excavation. The test results are not only of important reference value to the excavation and support of diversion tunnel at the Baihetan Hydropower Station, but also of great referential significance and value to the conduction of similar tests.

  17. What differences in the cultural backgrounds of partners are detrimental for international joint ventures?

    NARCIS (Netherlands)

    H.G. Barkema (Harry); G.A.M. Vermeulen (Freek)

    1997-01-01

    textabstractAn international joint venture implies that a firm has to cooperate with a partner with a different cultural background. In this study, hypotheses about which differences in national culture are most disruptive for international joint ventures were developed and tested using Hofstede's

  18. A novel multi-item joint replenishment problem considering multiple type discounts.

    Directory of Open Access Journals (Sweden)

    Ligang Cui

    Full Text Available In business replenishment, discount offers of multi-item may either provide different discount schedules with a single discount type, or provide schedules with multiple discount types. The paper investigates the joint effects of multiple discount schemes on the decisions of multi-item joint replenishment. In this paper, a joint replenishment problem (JRP model, considering three discount (all-unit discount, incremental discount, total volume discount offers simultaneously, is constructed to determine the basic cycle time and joint replenishment frequencies of multi-item. To solve the proposed problem, a heuristic algorithm is proposed to find the optimal solutions and the corresponding total cost of the JRP model. Numerical experiment is performed to test the algorithm and the computational results of JRPs under different discount combinations show different significance in the replenishment cost reduction.

  19. Development of dissimilar metal transition joint by hot bond rolling

    International Nuclear Information System (INIS)

    Kurokawa, Hiroyuki; Nakasuji, Kazuyuki; Kajimura, Haruhiko; Nagai, Takayuki; Takeda, Seiichiro.

    1997-01-01

    Metallurgically bonded transition joints which enable to connect reprocessing equipments made of superior corrosion resistant valve metals (Ti-5Ta, Zr or Ti) to stainless steel piping are required for nuclear fuel reprocessing plants. The authors have developed dissimilar transition joints made of stainless steel and Ti-5Ta, Zr or Ti with an insert metal of Ta by the hot bond rolling process of clad bars and clad pipes, using a newly developed mill called 'rotary reduction mill'. This report presents the manufacturing process of dissimilar transition joints produced from the clad pipe with three layers by the hot bond rolling. First, the method of hot bond rolling of clad pipe is proposed. Then, the mechanical and corrosion properties of the dissimilar transition joints are evaluated in detail by carrying out various tests. Finally, the rolling properties in the clad pipe method are discussed. (author)

  20. Cross-view gait recognition using joint Bayesian

    Science.gov (United States)

    Li, Chao; Sun, Shouqian; Chen, Xiaoyu; Min, Xin

    2017-07-01

    Human gait, as a soft biometric, helps to recognize people by walking. To further improve the recognition performance under cross-view condition, we propose Joint Bayesian to model the view variance. We evaluated our prosed method with the largest population (OULP) dataset which makes our result reliable in a statically way. As a result, we confirmed our proposed method significantly outperformed state-of-the-art approaches for both identification and verification tasks. Finally, sensitivity analysis on the number of training subjects was conducted, we find Joint Bayesian could achieve competitive results even with a small subset of training subjects (100 subjects). For further comparison, experimental results, learning models, and test codes are available.

  1. Experimental joint immobilization in guinea pigs. Effects on the knee joint

    Science.gov (United States)

    Marcondesdesouza, J. P.; Machado, F. F.; Sesso, A.; Valeri, V.

    1980-01-01

    In young and adult guinea pigs, the aftermath experimentally induced by the immobilization of the knee joint in hyperextended forced position was studied. Joint immobilization which varied from one to nine weeks was attained by plaster. Eighty knee joints were examined macro and microscopically. Findings included: (1) muscular hypotrophy and joint stiffness in all animals, directly proportional to the length of immobilization; (2) haemoarthrosis in the first week; (3) intra-articular fibrous tissue proliferation ending up with fibrous ankylosis; (4) hyaline articular cartilage erosions; (5) various degrees of destructive menisci changes. A tentative explanation of the fibrous tissue proliferation and of the cartilage changes is offered.

  2. Prosthesis of the wrist-joint

    Energy Technology Data Exchange (ETDEWEB)

    Feldmeier, C.

    1983-02-25

    Function of the hand-joint and the well-being of patients can be severely affected by arthrosis of the wrist-joint. Therapeutically, arthrodesis usually results in a painfree status of stiffness. A painless and well functioning joint can be achieved by alloplastic joint replacement or resurfacing. The possibilities and clinical results in cases of arthrosis of the carpo-metacarpal joint of the thumb, pseudarthrosis of the scaphoid, aseptic necrosis of the Lunate and severe arthrosis of the radio-carpal joint are demonstrated.

  3. Proximal tibiofibular joint: Rendezvous with a forgotten articulation

    Directory of Open Access Journals (Sweden)

    Amitav Sarma

    2015-01-01

    Full Text Available The proximal tibiofibular joint (PTFJ is a plane type synovial joint. The primary function of the PTFJ is dissipation of torsional stresses applied at the ankle and the lateral tibial bending moments besides a very significant tensile, rather than compressive weight bearing. Though rare, early diagnosis and treatment of the PTFJ dislocation are essential to prevent chronic joint instability and extensive surgical intervention to restore normal PTFJ biomechanics, ankle and knee function, especially in athletes prone to such injuries. PTFJ dislocations often remain undiagnosed in polytrauma scenario with ipsilateral tibial fracture due to the absence of specific signs and symptoms of PTFJ injury. Standard orthopedic textbooks generally describe no specific tests or radiological signs for assessment of the integrity of this joint. The aim of this paper was to review the relevant clinical anatomy, biomechanics and traumatic pathology of PTFJ with its effect on the knee emphasizing the importance of early diagnosis through a high index of suspicion. Dislocation of the joint may have serious implications for the knee joint stability since fibular collateral ligament and posterolateral ligament complex is attached to the upper end of the fibula. Any high energy knee injury with peroneal nerve palsy should immediately raise the suspicion of PTFJ dislocation especially if the mechanism of injury involved knee twisting in flexion beyond 80° and in such cases a comparative radiograph of the contralateral side should be performed. Wider clinical awareness can avoid both embarrassingly extensive surgeries due to diagnostic delays or unnecessary overtreatment due to misinformation on the part of the treating surgeon.

  4. [Short-term effectiveness of Swanson artificial joint replacement in treating posttraumatic metacarpophalangeal joint stiffness].

    Science.gov (United States)

    Lu, Hui; Shen, Xiangqian; Xu, Jihua; Huang, Xin; Ye, Po; Wu, Shoucheng

    2011-11-01

    To investigate the short-term effectiveness of Swanson artificial joint replacement in treating post-traumatic metacarpophalangeal joint stiffness. Between August 2007 and May 2010, 11 cases (13 fingers) of metacarpophalangeal joint stiffness with soft tissue defects underwent Swanson artificial joint replacement. There were 7 males (9 fingers) and 4 females (4 fingers), aged 43 to 65 years with an average of 49 years. The involved fingers included 4 thumbs, 4 index fingers, 3 middle fingers, and 2 ring fingers. The types of injury included open and crush injury in 8 fingers, fracture of the metacarpophalangeal joint in 3 fingers, metacarpophalangeal joint severing in 2 fingers. The time from joint stiffness to hospitalization was 12 to 48 weeks (mean, 24 weeks). The joint activity was (136.82 +/- 28.96) degrees. According to total active motion (TAM) assessment, included good in 1 finger, fair in 6 fingers, and poor in 6 fingers before operation. The activities of daily living were assessed by Sollerman score, which was 45.64 +/- 11.04. The X-ray films and CT scan showed traumatic arthritis of the metacarpophalangeal joint. The incision healed by first intention. All patients were followed up 12 to 34 months (mean, 24.1 months). At last follow-up, the joint activity was (194.64 +/- 28.86) degrees, showing significant difference when compared with preoperative value (t = 25.214, P = 0.000). According to TAM assessment, including excellent in 1 finger, good in 4 fingers, fair in 7 fingers, and poor in 1 finger. The Sollerman score was 67.45 +/- 8.20 postoperatively, showing significant difference when compared with the preoperative score (t = -10.470, P = 0.000). X-ray examination showed no prosthesis fracture, periprosthetic fracture, or joint dislocation occurred at last follow-up. Swanson artificial joint replacement can be applied to treat post-traumatic metacarpophalangeal joint stiffness, which can improve the joint activity and has satisfactory short

  5. Mechanical properties and fatigue strength of high manganese non-magnetic steel/carbon steel welded joints

    International Nuclear Information System (INIS)

    Nakaji, Eiji; Ikeda, Soichi; Kim, You-Chul; Nakatsuji, Yoshihiro; Horikawa, Kosuke.

    1997-01-01

    The dissimilar materials welded joints of high manganese non-magnetic steel/carbon steel (hereafter referred to as DMW joints), in which weld defects such as hot crack or blowhole are not found, were the good quality. Tensile strength of DMW joints was 10% higher than that of the base metal of carbon steel. In the bend tests, the DMW joints showed the good ductility without crack. Charpy absorbed energy at 0(degC) of the DMW joints was over 120(J) in the bond where it seems to be the lowest. Large hardening or softening was not detected in the heat affected zone. Fatigue strength of the DMW joints is almost the same with that of the welded joints of carbon steel/carbon steel. As the fatigue strength of the DMW joints exceeds the fatigue design standard curve of JSSC for carbon steel welded joints, the DMW joints can be treated the same as the welded joints of carbon steel/carbon steel of which strength is lower than that of high manganese non-magnetic steel, from the viewpoint of the fatigue design. (author)

  6. Corrosion resistance of a laser spot-welded joint of NiTi wire in simulated human body fluids.

    Science.gov (United States)

    Yan, Xiao-Jun; Yang, Da-Zhi

    2006-04-01

    The purpose of this study was to investigate corrosion resistance of a laser spot-welded joint of NiTi alloy wires using potentiodynamic tests in Hank's solution at different PH values and the PH 7.4 NaCl solution for different Cl- concentrations. Scanning electron microscope observations were carried out before and after potentiodynamic tests. The composition of a laser spot-welded joint and base metal were characterized by using an electron probe microanalyzer. The results of potentiodynamic tests showed that corrosion resistance of a laser spot-welded joint of NiTi alloy wire was better than that of base metal, which exhibited a little higher breakdown potential and passive range, and a little lower passive current density. Corrosion resistances of a laser spot-welded joint and base metal decreased with increasing of the Cl- concentration and PH value. The improvement of corrosion resistance of the laser spot-welded joint was due to the decrease of the surface defects and the increase of the Ti/Ni ratio. (c) 2005 Wiley Periodicals, Inc.

  7. Compression-rate-dependent nonlinear mechanics of normal and impaired porcine knee joints.

    Science.gov (United States)

    Rodriguez, Marcel Leonardo; Li, LePing

    2017-11-14

    The knee joint performs mechanical functions with various loading and unloading processes. Past studies have focused on the kinematics and elastic response of the joint with less understanding of the rate-dependent load response associated with viscoelastic and poromechanical behaviors. Forty-five fresh porcine knee joints were used in the present study to determine the loading-rate-dependent force-compression relationship, creep and relaxation of normal, dehydrated and meniscectomized joints. The mechanical tests of all normal intact joints showed similar strong compression-rate-dependent behavior: for a given compression-magnitude up to 1.2 mm, the reaction force varied 6 times over compression rates. While the static response was essentially linear, the nonlinear behavior was boosted with the increased compression rate to approach the asymptote or limit at approximately 2 mm/s. On the other hand, the joint stiffness varied approximately 3 times over different joints, when accounting for the maturity and breed of the animals. Both a loss of joint hydration and a total meniscectomy greatly compromised the load support in the joint, resulting in a reduction of load support as much as 60% from the corresponding intact joint. However, the former only weakened the transient load support, but the latter also greatly weakened the equilibrium load support. A total meniscectomy did not diminish the compression-rate-dependence of the joint though. These findings are consistent with the fluid-pressurization loading mechanism, which may have a significant implication in the joint mechanical function and cartilage mechanobiology.

  8. Phytomedicine in Joint Disorders

    Directory of Open Access Journals (Sweden)

    Dorin Dragos

    2017-01-01

    Full Text Available Chronic joint inflammatory disorders such as osteoarthritis and rheumatoid arthritis have in common an upsurge of inflammation, and oxidative stress, resulting in progressive histological alterations and disabling symptoms. Currently used conventional medication (ranging from pain-killers to biological agents is potent, but frequently associated with serious, even life-threatening side effects. Used for millennia in traditional herbalism, medicinal plants are a promising alternative, with lower rate of adverse events and efficiency frequently comparable with that of conventional drugs. Nevertheless, their mechanism of action is in many cases elusive and/or uncertain. Even though many of them have been proven effective in studies done in vitro or on animal models, there is a scarcity of human clinical evidence. The purpose of this review is to summarize the available scientific information on the following joint-friendly medicinal plants, which have been tested in human studies: Arnica montana, Boswellia spp., Curcuma spp., Equisetum arvense, Harpagophytum procumbens, Salix spp., Sesamum indicum, Symphytum officinalis, Zingiber officinalis, Panax notoginseng, and Whitania somnifera.

  9. Research on fatigue behavior and residual stress of large-scale cruciform welding joint with groove

    International Nuclear Information System (INIS)

    Zhao, Xiaohui; Liu, Yu; Liu, Yong; Gao, Yuan

    2014-01-01

    Highlights: • The fatigue behavior of the large-scale cruciform welding joint with groove was studied. • The longitudinal residual stress of the large-scale cruciform welding joint was tested by contour method. • The fatigue fracture mechanism of the large-scale cruciform welding joint with groove was analyzed. - Abstract: Fatigue fracture behavior of the 30 mm thick Q460C-Z steel cruciform welded joint with groove was investigated. The fatigue test results indicated that fatigue strength of 30 mm thick Q460C-Z steel cruciform welded joint with groove can reach fatigue level of 80 MPa (FAT80). Fatigue crack source of the failure specimen initiated from weld toe. Meanwhile, the microcrack was also found in the fusion zones of the fatigue failure specimen, which was caused by weld quality and weld metal integrity resulting from the multi-pass welds. Two-dimensional map of the longitudinal residual stress of 30 mm thick Q460C-Z steel cruciform welded joint with groove was obtained by using the contour method. The stress nephogram of Two-dimensional map indicated that longitudinal residual stress in the welding center is the largest

  10. A Review of Natural Joint Systems and Numerical Investigation of Bio-Inspired GFRP-to-Steel Joints

    Directory of Open Access Journals (Sweden)

    Evangelos I. Avgoulas

    2016-07-01

    Full Text Available There are a great variety of joint types used in nature which can inspire engineering joints. In order to design such biomimetic joints, it is at first important to understand how biological joints work. A comprehensive literature review, considering natural joints from a mechanical point of view, was undertaken. This was used to develop a taxonomy based on the different methods/functions that nature successfully uses to attach dissimilar tissues. One of the key methods that nature uses to join dissimilar materials is a transitional zone of stiffness at the insertion site. This method was used to propose bio-inspired solutions with a transitional zone of stiffness at the joint site for several glass fibre reinforced plastic (GFRP to steel adhesively bonded joint configurations. The transition zone was used to reduce the material stiffness mismatch of the joint parts. A numerical finite element model was used to identify the optimum variation in material stiffness that minimises potential failure of the joint. The best bio-inspired joints showed a 118% increase of joint strength compared to the standard joints.

  11. Prosthesis of the wrist-joint

    International Nuclear Information System (INIS)

    Feldmeier, C.

    1983-01-01

    Function of the hand-joint and the well-being of patients can be severely affected by arthrosis of the wrist-joint. Therapeutically, arthrodesis usually results in a painfree status of stiffness. A painless and well functioning joint can be achieved by alloplastic joint replacement or resurfacing. The possibilities and clinical results in cases of arthrosis of the carpo-metacarpal joint of the thumb, pseudarthrosis of the scaphoid, aseptic necrosis of the Lunate and severe arthrosis of the radio-carpal joint are demonstrated. (orig.) [de

  12. Comparative Analysis of Welded and Adhesive Joints Strength Made of Acid-Resistant Stainless Steel Sheets

    Directory of Open Access Journals (Sweden)

    Izabela Miturska

    2017-12-01

    Full Text Available The article presents the selected results of strength tests on the effectiveness of bonding high-alloy steel 1.4310. Sheet steel is one of the materials that are difficult to activate energy. Effective joining of it is difficult, requires selection of the appropriate bonding technology. The paper focuses on the comparative tests the shear strength of one-single lap welded and bonded joints. The welding process was performed 3 groups of samples TIG welding and argon, where the variable value of the welding process was current: 60A, 70A, 80A. The adhesion process was performed in 6 groups of samples which differed in the method of surface preparation and the type of the adhesive. Adhesive joints were made by using adhesive of epoxy resin and a hardener: Epidian 61/TFF at a mass ratio of 100:22 and Epidian 61/IDA at a mass ratio of 100:40. As a way of surface preparation applied 3 different, but simplified and environmentally friendly methods of surface preparation: degreasing with using cleaner Loctite 7061, abrasive machining with P320 and degreasing and grinding with abrasive T800 and degreasing were used. Make joints and curing the adhesive joints were carried out at ambient temperature. Analyzed the joints were tested destructive - which set out the shear strength, in accordance with DIN EN 1465 on the testing machine Zwick / Roell Z150. Based on the results of research it was found that better results were obtained for the maximum welded joints, but this result was similar to the maximum value of the strength of the adhesive bond.

  13. Design of mechanical joints

    CERN Document Server

    Blake, Alexander

    2018-01-01

    A cornerstone publication that covers the basic principles and practical considerations of design methodology for joints held by rivets, bolts, weld seams, and adhesive materials, Design of Mechanical Joints gives engineers the practical results and formulas they need for the preliminary design of mechanical joints, combining the essential topics of joint mechanics...strength of materials...and fracture control to provide a complete treatment of problems pertinent to the field of mechanical connections.

  14. Computerized tomography of the mandibular joints and masticatory muscles

    International Nuclear Information System (INIS)

    Huels, A.B.

    1981-01-01

    A methodology for computerized tomography of the mandibular joints was developed and applied in 80 test persons. Imaging of the mandibular joints is possible with a tomographic technique with 5 mm-overlap, full utilisation of the enlargement capacity of the imaging device, and combined use of transversal and coronary tomography. The method yields full latero-medial, cranio-caudal and anterior-posterior views of the condyle and fossa contours, free of interferences and of distortions caused by the projection. Positional diagnoses are thus possible as well as diagnoses of pathological structural changes. (orig./MG) [de

  15. Joint involvement in Lö fgren's syndrome

    Directory of Open Access Journals (Sweden)

    O. N. Egorova

    2016-01-01

    Full Text Available Objective: to study the clinical, laboratory, and instrumental features of joint involvement in patients with Löfgren's syndrome.Patients and methods. Examinations were made in 125 patients, among whom there were 21 men and 104 women (male:female ratio, 1:5; mean age, 42±12 years (from 18 to 69 years, the referral diagnoses were erythema nodosum (EN, panniculitis or vasculitis.Results. All the patients complained of painful red indurations on the upper and lower extremities; there were also complaints of joint pain (83%, cough, weakness, hyperhidrosis, dyspnea, myalgia, and sore throat (55%, and subfebrile temperatures (50%. Arthralgias were noted in all the cases; 70% had arthritis that was observed manly in the ankle joints (62%. In all the patients, joint damage was concurrent with EN. Articular manifestations preceded EN in 35 (28% patients. Laboratory tests showed that the median erythrocyte sedimentation rate was 20 [14; 31] mm/hr and C-reactive protein (CRP was 10 [6; 21] mg/l. Elevated CRP levels were significantly more common in arthritis (p = 0.003 and nodular fusion (p=0.04 and directly related to the number of subcutaneous nodules (p=0.008; r=0.29. Chest computed tomography revealed intrathoracic lymphadenopathy in all the patients; ground glass lung tissue injury (Stage II was identified in 42% of cases. Joint damage did not depend on the X-ray stage of sarcoidosis. 54% of the patients took nonsteroidal anti-inflammatory drugs, 60% received hydroxychloroquine 600 mg/day, and 50% had glucocorticoids (GC 4–6 mg/day. 35% of the patients received combined therapy with GC and cyclophosphamide 200 mg/week or methotrexate 15 mg/week. Articular syndrome virtually completely regressed during a year. Arthralgias in the ankle persisted in a few (4% cases.

  16. Part I. Remembering No. 2 (Ladislav Loerinc). EMO joint venture, joint-stock company - really completely useless organ?

    International Nuclear Information System (INIS)

    Blaha, M.

    2008-01-01

    In this chapter author reviewed the story of the EMO joint venture, joint-stock company, between Slovenske elektrarne, a. s. and EdF. EMO joint venture, joint-stock company, was established to complete the Mochovce nuclear power plant. EMO joint venture, joint-stock company was closed after one year of work. History of EMO joint venture, joint-stock company, was described by its former general manager Mr. Ladislav Loerinc.

  17. T2-mapping of the sacroiliac joints at 1.5 Tesla: a feasibility and reproducibility study.

    Science.gov (United States)

    Albano, Domenico; Chianca, Vito; Cuocolo, Renato; Bignone, Rodolfo; Ciccia, Francesco; Sconfienza, Luca Maria; Midiri, Massimo; Brunetti, Arturo; Lagalla, Roberto; Galia, Massimo

    2018-04-20

    To evaluate the reproducibility of T2 relaxation time measurements of the sacroiliac joints at 1.5 T. Healthy volunteers underwent an oblique axial multislice multiecho spin-echo sequence of the sacroiliac joints at 1.5 T. Regions of interest were manually drawn using a dedicated software by two musculoskeletal radiologists to include the cartilaginous part of the sacroiliac joints. A senior radiologist performed the measurement twice, while a resident measured once. Intra- and inter-observer reproducibility was tested using the Bland-Altman method. Association between sex and T2 relaxation times was tested using the Mann-Whitney U test. Correlation between T2 relaxation times and body mass index (BMI) was tested using the Spearman's rho. Eighty sacroiliac joints of 40 subjects (mean age: 28 ± 4.8 years, range: 20-43; mean BMI: 23.3 ± 3.1, range: 18.9-30) were imaged. The mean T2 values obtained by the senior radiologist in the first series of measurements were 42 ± 4.4 ms, whereas in the second series were 40.7 ± 4.5 ms. The mean T2 values obtained by the radiology resident were 41.1 ± 4.2 ms. Intra-observer reproducibility was 88% (coefficient of repeatability = 3.8; bias = 1.28; p sacroiliac joints seems to be highly reproducible at 1.5 T. Further studies could investigate the potential clinical application of this tool in the sacroiliac joints.

  18. Forming a multinational joint venture

    International Nuclear Information System (INIS)

    Bhatia, N.K.; Garb, R.H.; Statton, T.D.

    1990-01-01

    This paper discusses the basis and mechanics for forming a multinational joint venture. The topics of the paper include the motivations for a joint venture, selection of the appropriate co-venturer, management of the multinational joint venture, and the joint venture agreement. The authors state that a joint venture is not applicable or desirable in all instances and to be successful, must be carefully planned

  19. Nuclear EMP: stripline test method for measuring transfer impedance

    International Nuclear Information System (INIS)

    Miller, J.S.

    1975-11-01

    A method for measuring the transfer impedance of flat metal joints for frequencies to 100 MHz has been developed which makes use of striplines. The stripline method, which has similarities to the quadraxial method used for cylindrical components, is described and sets of test results are given. The transfer impedance of a simple joint is modeled as a spurious hyperbolic curve, and a close curve fit to transfer impedance test data from various samples is demonstrated for both the stripline and the quadraxial methods. Validity checks of the test data are discussed using the curve model and other criteria. The method was developed for testing riveted joints which form the avionics bays on B-1s. The joints must provide shielding from EMP currents

  20. Joint imaging

    International Nuclear Information System (INIS)

    Hengst, W.

    1984-01-01

    Joint imaging is a proven diagnostic procedure which has become indispensable to the detection and treatment of different joint diseases in almost all disciplines. The method is suited for early diagnosis of joint affections both in soft tissue and bone which cannot be detected by X-ray or other procedures. The local activity accumulation depends on the rate of metabolism and is visualized in the scan, which in turn enables the extension and floridity of focal lesions to be evaluated and followed-up. Although joint scans may often give hints to probabilities relevant to differential diagnosis, the method is non-specific and only useful if based on the underlying clinical picture and X-ray finding, if possible. The radiation exposure is very low and does not represent a hazard in cases of adequate assessment of indication. In pregnant women and children the assessment of indication has to be based on very strict principles. The method is suited for out-patient diagnosis and can be applied in all installations equipped with a gamma camera and a technetium generator. (orig.) [de

  1. Managing Joint Production Motivation

    DEFF Research Database (Denmark)

    Lindenberg, Siegwart; Foss, Nicolai Juul

    2011-01-01

    We contribute to the microfoundations of organizational performance by proffering the construct of joint production motivation. Under such motivational conditions individuals see themselves as part of a joint endeavor, each with his or her own roles and responsibilities; generate shared...... representations of actions and tasks; cognitively coordinate cooperation; and choose their own behaviors in terms of joint goals. Using goal-framing theory, we explain how motivation for joint production can be managed by cognitive/symbolic management and organizational design....

  2. Rock mass deformation properties of closely jointed basalt

    International Nuclear Information System (INIS)

    Kim, K.; Cramer, M.L.

    1982-12-01

    The deformational behavior of the Columbia River basalt is being investigated as part of a comprehensive site characterization program intended to determine the feasibility of constructing a nuclear waste repository in basalt at Hanford, Washington. Direct field measurements were conducted in a 2-m cube of basalt to obtain truly representative rock mass deformation properties. Load was applied to the test block in three orthogonal directions through the use of flat jacks in two perpendicular planes and a cable anchor system in the third. This configuration allowed the block to be placed in a simulated triaxial stress state at stress levels up to 12.5 MPa. The deformation at the center of the test block was monitored through the use of an optical measurement system developed for this project. The results indicate that the vertically oriented columnar joints have a significant influence on the deformation behavior of the basalt. The modulus in the direction parallel to the column axis was approx. 30 GPa, while the modulus value perpendicular to the columns was approx. 20 GPa. Laboratory measurements of intact specimens taken from this area yielded a value of 80 GPa with no indication of anisotropy. Hysteresis was observed in all loading cycles, but was distinctly more pronounced perpendicular to the column axis, indicative of significant joint displacement in this direction. The results of this test represent the first true rock mass modulus data obtained in closely jointed rock on a large scale. These measurement methods have eliminated many of the ambiguities associated with borehole jacking and surface measurement techniques

  3. Mechanics of Suture Joints

    Science.gov (United States)

    Li, Yaning; Song, Juha; Ortiz, Christine; Boyce, Mary; Ortiz Group/DMSE/MIT Team; Boyce Group/ME/MIT Team

    2011-03-01

    Biological sutures are joints which connect two stiff skeletal or skeletal-like components. These joints possess a wavy geometry with a thin organic layer providing adhesion. Examples of biological sutures include mammalian skulls, the pelvic assembly of the armored fish Gasterosteus aculeatus (the three-spined stickleback), and the suture joints in the shell of the red-eared slider turtle. Biological sutures allow for movement and compliance, control stress concentrations, transmit loads, reduce fatigue stress and absorb energy. In this investigation, the mechanics of the role of suture geometry in providing a naturally optimized joint is explored. In particular, analytical and numerical micromechanical models of the suture joint are constructed. The anisotropic mechanical stiffness and strength are studied as a function of suture wavelength, amplitude and the material properties of the skeletal and organic components, revealing key insights into the optimized nature of these ubiquitous natural joints.

  4. Generalised joint hypermobility and knee joint hypermobility: prevalence, knee joint symptoms and health-related quality of life in a Danish adult population.

    Science.gov (United States)

    Junge, Tina; Henriksen, Peter; Hansen, Sebrina; Østengaard, Lasse; Golightly, Yvonne M; Juul-Kristensen, Birgit

    2017-10-27

    Several biomechanical factors, such as knee joint hypermobility (KJH), are suggested to play a role in the etiology of knee joint symptoms and knee osteoarthritis. Nevertheless, the prevalence or consequences of KJH solely or included in the classification of generalized joint hypermobility (GJHk) is unknown for a general population. Therefore, the objectives were to report the prevalence of self-reported GJHk and KJH, as well as the association of these conditions to knee joint symptoms, severity and duration of symptoms, and health-related quality of life (HRQoL) in a Danish adult population. This study is a cross-sectional population-based survey of 2056 Danish adults. Respondents received online questionnaires of GJHk and KJH, knee joint symptoms, the severity and duration of these, as well as HRQoL. Total response rate was 49% (n = 1006). The prevalence of self-reported GJHk and KJH was 13% and 23%, mostly representing women. More than half of the respondents with GJHk and KJH had knee joint symptoms. The odds for reporting knee joint symptoms, severity of knee joint symptoms and duration of knee joint symptoms were twice as high for respondents with GJHk and KJH. Respondents with GJHk and KJH reported lower HRQoL. GJHk and KJH were frequently reported in the Danish adult population, mostly in women. Respondents with GJHk and KJH were two times more likely to report knee joint-related symptoms such as pain, reduced performance of usual activity and lower HRQoL. The impact of these conditions on HRQoL is comparable with knee osteoarthritis. © 2017 Asia Pacific League of Associations for Rheumatology and John Wiley & Sons Australia, Ltd.

  5. Heat Exchanger Tube to Tube Sheet Joints Corrosion Behavior

    Directory of Open Access Journals (Sweden)

    M. Iancu

    2013-03-01

    Full Text Available Paper presents the studies made by the authors above the tube to tube sheet fittings of heat exchanger with fixed covers from hydrofining oil reforming unit. Tube fittings are critical zones for heat exchangers failures. On a device made from material tube and tube sheet at real joints dimensions were establish axial compression force and traction force at which tube is extracted from expanded joint. Were used two shapes joints with two types of fittings surfaces, one with smooth hole of tube sheet and other in which on boring surface we made a groove. From extracted expanded tube zones were made samples for corrosion tests in order to establish the corrosion rate, corrosion potential and corrosion current in working mediums such as hydrofining oil and industrial water at different temperatures. The corrosion rate values and the temperature influence are important to evaluate joints durability and also the results obtained shows that the boring tube sheet shape with a groove on hole tube shape presents a better corrosion behavior then the shape with smooth hole tube sheet.

  6. Joint Intentionality

    Directory of Open Access Journals (Sweden)

    Koreň Ladislav

    2016-03-01

    Full Text Available According to the shared intentionality hypothesis proposed by Michael Tomasello, two cognitive upgrades – joint and collective intentionality, respectively – make human thinking unique. Joint intentionality, in particular, is a mindset supposed to account for our early, species-specific capacity to participate in collaborative activities involving two (or a few agents. In order to elucidate such activities and their proximate cognitive-motivational mechanism, Tomasello draws on philosophical accounts of shared intentionality. I argue that his deference to such cognitively demanding accounts of shared intentional activities is problematic if his theoretical ambition is in part to show that and how early (prelinguistic and precultural capacities for joint action contribute to the development of higher cognitive capacities.

  7. Provocative mechanical tests of the peripheral nervous system affect the joint torque-angle during passive knee motion.

    Science.gov (United States)

    Andrade, R J; Freitas, S R; Vaz, J R; Bruno, P M; Pezarat-Correia, P

    2015-06-01

    This study aimed to determine the influence of the head, upper trunk, and foot position on the passive knee extension (PKE) torque-angle response. PKE tests were performed in 10 healthy subjects using an isokinetic dynamometer at 2°/s. Subjects lay in the supine position with their hips flexed to 90°. The knee angle, passive torque, surface electromyography (EMG) of the semitendinosus and quadriceps vastus medialis, and stretch discomfort were recorded in six body positions during PKE. The different maximal active positions of the cervical spine (neutral; flexion; extension), thoracic spine (neutral; flexion), and ankle (neutral; dorsiflexion) were passively combined for the tests. Visual analog scale scores and EMG were unaffected by body segment positioning. An effect of the ankle joint was verified on the peak torque and knee maximum angle when the ankle was in the dorsiflexion position (P torque (P torque when the cervical and thoracic spines were flexed (P torque-angle response since different positions of head, upper trunk, and foot induce dissimilar knee mechanical responses during passive extension. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Joint Technical Coordinating Group on Aircraft Survivability (JTCG/AS). Bibliography of Joint Aircraft Survivability Reports

    Science.gov (United States)

    2000-07-01

    PMSG ). Report No.: JTCG/AS-99-D-003 Report Classification: UNCLASSIFIED Title: JTCG/AS Bibliography of Joint Aircraft Survivability Reports and...indicates those approved and not approved for funding by the Principal Members Steering Group ( PMSG ). Report No.: Report Classification: JTCG/AS-97-V-010...demonstrated by additional tests conducted at NWSC/Crane (up to Mach 0.8) and Rockwell International wind tunnel (up to Mach 1/9 and 30,000 feet altitude

  9. Compensating for intersegmental dynamics across the shoulder, elbow, and wrist joints during feedforward and feedback control.

    Science.gov (United States)

    Maeda, Rodrigo S; Cluff, Tyler; Gribble, Paul L; Pruszynski, J Andrew

    2017-10-01

    Moving the arm is complicated by mechanical interactions that arise between limb segments. Such intersegmental dynamics cause torques applied at one joint to produce movement at multiple joints, and in turn, the only way to create single joint movement is by applying torques at multiple joints. We investigated whether the nervous system accounts for intersegmental limb dynamics across the shoulder, elbow, and wrist joints during self-initiated planar reaching and when countering external mechanical perturbations. Our first experiment tested whether the timing and amplitude of shoulder muscle activity account for interaction torques produced during single-joint elbow movements from different elbow initial orientations and over a range of movement speeds. We found that shoulder muscle activity reliably preceded movement onset and elbow agonist activity, and was scaled to compensate for the magnitude of interaction torques arising because of forearm rotation. Our second experiment tested whether elbow muscles compensate for interaction torques introduced by single-joint wrist movements. We found that elbow muscle activity preceded movement onset and wrist agonist muscle activity, and thus the nervous system predicted interaction torques arising because of hand rotation. Our third and fourth experiments tested whether shoulder muscles compensate for interaction torques introduced by different hand orientations during self-initiated elbow movements and to counter mechanical perturbations that caused pure elbow motion. We found that the nervous system predicted the amplitude and direction of interaction torques, appropriately scaling the amplitude of shoulder muscle activity during self-initiated elbow movements and rapid feedback control. Taken together, our results demonstrate that the nervous system robustly accounts for intersegmental dynamics and that the process is similar across the proximal to distal musculature of the arm as well as between feedforward (i

  10. Elastic dynamic research of high speed multi-link precision press considering structural stiffness of rotation joints

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Feng Feng; Sun, Yu; Peng, Bin Bin [School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing (China)

    2016-10-15

    An elastic dynamic model of high-speed multi-link precision press considering structural stiffness of rotation joints was established by the finite element method. In the finite element model, rotation joint was established by four bar elements with equivalent stiffness, and connected link was established by beam element. Then, the elastic dynamics equation of the system was established, and modal superposition method was used to solve the dynamic response. Compared with the traditional elastic dynamic model with perfect constraint of the rotation joints, the elastic dynamic response value of the improved model is larger. To validate the presented new method of elastic dynamics analysis with stiffness of rotation joints, a related test of slider Bottom dead center (BDC) position in different speed was designed. The test shows that the model with stiffness of rotation joints is more reasonable. So it provides a reasonable theory and method for dynamic characteristics research of such a multi-link machine.

  11. The stress-corrosion behaviour in water media containing chlorine of the brazing joint of grids for PWR fuel element

    International Nuclear Information System (INIS)

    Zhang Weijie; Li Wenqing.

    1985-01-01

    This paper details the testing results of the stress-corrosion behaviour in the 150 deg C water media containing chlorine for the brazing joints made from three alloy systems, which are Ni-Cr-Si, Ni-Cr-P and Ni-P, including 16 compositions. The test results indicate that, in the Ni-Cr-Si system, Ni-Cr-Si-Ge brazing joint is the best, to resist stress-corrosion, while Ni-Cr-Si-P-Ge-Pd and BNi5 brazing joints are better. In the Ni-Cr-P system, only the Ni-Cr-P-Mo-Zr brazing joint has an excellent resistance to stress-corrosion

  12. Effect of Shielding Gas on the Properties of AW 5083 Aluminum Alloy Laser Weld Joints

    Science.gov (United States)

    Vyskoč, Maroš; Sahul, Miroslav; Sahul, Martin

    2018-04-01

    The paper deals with the evaluation of the shielding gas influence on the properties of AW 5083 aluminum alloy weld joints produced with disk laser. Butt weld joints were produced under different shielding gas types, namely Ar, He, Ar + 5 vol.% He, Ar + 30 vol.% He and without shielding weld pool. Light and electron microscopy, computed tomography, microhardness measurements and tensile testing were used for evaluation of weld joint properties. He-shielded weld joints were the narrowest ones. On the other hand, Ar-shielded weld joints exhibited largest weld width. The choice of shielding gas had significant influence on the porosity level of welds. The lowest porosity was observed in weld joint produced in Ar with the addition of 5 vol.% He shielding atmosphere (only 0.03%), while the highest level of porosity was detected in weld joint produced in pure He (0.24%). Except unshielded aluminum alloy weld joint, the lowest tensile strength was recorded in He-shielded weld joints. On the contrary, the highest average microhardness was measured in He-shielded weld joints.

  13. Formation of sheeting joints in Yosemite National Park, California

    Science.gov (United States)

    Martel, S. J.

    2009-04-01

    The formation of sheeting joints (i.e., "exfoliation joints"), opening mode fractures subparallel to the Earth's surface, has been a classic unresolved problem in geology. Diverse new observations and analyses support the hypothesis that sheeting joints develop in response to a near-surface tension induced by compressive stresses parallel to a convex slope (hypothesis 1) rather than the conventional explanation that the joints form as a result of removal of overburden by erosion (hypothesis 2). The opening mode displacements across the joints together with the absence of mineral precipitates within the joints mean that sheeting joints open in response to a near-surface tension normal to the surface (N) rather than a pressurized fluid. An absolute tension must arise in the shallow subsurface if a plot of N as a function of depth normal to the surface (z) has a positive slope at the surface (z=0). The differential equations of static equilibrium require that this slope (derivative) equals k2 P22 + k3 P33 - ?g cosβ, where k2 and k3 are the principal curvatures of the surface, P22 and P33 are the respective surface-parallel normal stresses along the principal curvatures, ? is the material density, g is gravitational acceleration, and β is the slope. This derivative will be positive and sheeting joints can open if the surface-parallel stress in at least one direction is sufficiently compressive (negative) and the curvature in that direction is sufficiently convex (negative). Hypotheses 1 and 2 are being tested using geologic mapping and aerial LIDAR data from Yosemite National Park, California. The abundance of sheeting joints on convex ridges there, where erosion is a local minimum, coupled with their scarcity in the adjacent concave valleys, where erosion is a local maximum, is consistent with hypothesis 1 but inconsistent with hypothesis 2. At several sites with sheeting joints, measurements of the current topographic curvatures and the current surface

  14. Experimental and Numerical Analysis of Steel Joints in Round Wood

    Directory of Open Access Journals (Sweden)

    Mikolášek David

    2014-12-01

    Full Text Available The paper analyses a drawn steel joint in round logs for which several types of reinforcements have been proposed. The load-carrying capacity of the reinforcements have been tested in laboratories. At the same time, numerical modelling has been performed - it has focused, in particular, on rigidity of the joints during the loading process. Physical and geometrical nonlinearities have been taken into account. The Finite Element Method and 3D computation models have been used in the numerical calculations.

  15. Effects of the curing pressure on the torsional fatigue characteristics of adhesively bonded joints

    International Nuclear Information System (INIS)

    Hwang, Hui Yun; Kim, Byung Jung; Lee, Dai Gil

    2004-01-01

    Adhesive joints have been widely used for fastening thin adherends because they can distribute the load over a larger area than mechanical joints, require no hole, add very little weight to the structure and have superior fatigue resistance. However, the fatigue characteristics of adhesive joints are much affected by applied pressure during curing operation because actual curing temperature is changed by applied pressure and the adhesion characteristics of adhesives are very sensitive to manufacturing conditions. In this study, cure monitoring and torsional fatigue tests of adhesive joints with an epoxy adhesive were performed in order to investigate the effects of the applied pressure during curing operation. From the experiments, it was found that the actual curing temperature increased as the applied pressure increased, which increased residual thermal stress in the adhesive layer. Therefore, the fatigue life decreased as the applied pressure increased because the mean stress during fatigue tests increased due to the residual thermal stress

  16. The temporomandibular joint

    International Nuclear Information System (INIS)

    Campbell, W.

    1984-01-01

    Whilst the temporomandibular joint is in many ways unique, it is subject to all the diseases and disorders found in joints in other parts of the human skeleton. By far the most common disorder is injury, followed by arthropathy, acute and chronic dislocations, ankylosis, and in rare instances, neoplasms. The diagnosis and management of the temporomandibular joint are the primary responsibility of the oral surgeon. Nevertheless, this anatomical region is an area in which the cooperation of medical and dental disciplines may be required for the satisfactory conclusion of treatment. The more so when the disease process involves either associated psychosomatic illness or malignancy. The mainstay of the diagnosis is a careful radiological examination of the joint. There exists a delicate relationship between the dentition, the muscles of mastication, and the temporomandibular articulation, which is controlled by arthrokinetic reflex activity of the branches of the 5th cranial nerve. Imbalance between one or more of the components of this integrated system frequently leads to disturbances in function. Pain-dysfunction disorders constitute the larger part of temporomandibular joint disturbances generally encountered

  17. Structure and Corrosion Resistance of Welded Joints of Alloy 1151 in Marine Atmosphere

    Science.gov (United States)

    Bakulo, A. V.; Yakushin, B. F.; Puchkov, Yu. A.

    2017-07-01

    The corrosion behavior of joints formed by TIG and IMIG welding from clad sheets of heat-hardenable aluminum alloy 1151 of the Al - Cu - Mg system is studied. The corrosion tests are performed in an aqueous solution of NaCl in a salt-spray chamber. The welded joints are subjected to a metallographic analysis.

  18. Design a Fuzzy Logic Controller for a Rotary Flexible Joint Robotic Arm

    Directory of Open Access Journals (Sweden)

    Jalani Jamaludin

    2018-01-01

    Full Text Available The purpose of this research is to design a fuzzy logic feedback controller (FLC in order to control a desired tip angle position a rotary flexible joint robotic arm. The FLC is also employed to dampen the vibration emanated from a rotary flexible joint robotic arm when reaching a desired tip angle position. The performance of FLC is tested in simulation and experiment. It is found that the FLC is successfully designed, applied and tested. The results show that fuzzy logic controller performed satisfactorily control a desired tip angle position and reduce the oscillations.

  19. Analysis on Adhesively-Bonded Joints of FRP-steel Composite Bridge under Combined Loading : Arcan Test Study and Numerical Modeling

    NARCIS (Netherlands)

    Jiang, X.; Qiang, X.; Kolstein, M.H.; Bijlaard, F.S.K.

    2016-01-01

    The research presented in this paper is an experimental study and numerical analysis on mechanical behavior of the adhesively-bonded joint between FRP sandwich bridge deck and steel girder. Generally, there are three typical stress states in the adhesively-bonded joint: shear stress, tensile stress,

  20. Defect accumulation in welded joints of 12Kh1MF steel steam pipelines during creep

    International Nuclear Information System (INIS)

    Anokhov, A.E.; Alekhova, I.A.

    1982-01-01

    Technique for investigation of micropore accumulation in 12Kh1MF steel welded joints is proposed. The micropore density in different zones of welded joints in non-uniform. It is shown that failure localization in welded joint in the softening zone during the creep takes place due to the micropore priority accumulation in this zone. It is found out that accumulation of residual deformations in different zones of 12Kh1MF welded joints under creep runs more uniformly as the level of working stresses decreases and test duration increases