WorldWideScience

Sample records for glyoxylate shunt enzymes

  1. Isolation and characterization of Salmonella typhimurium glyoxylate shunt mutants.

    OpenAIRE

    Wilson, R B; Maloy, S R

    1987-01-01

    Growth of Salmonella typhimurium on acetate as a sole carbon source requires expression of the glyoxylate shunt; however, the genes for the glyoxylate shunt enzymes have not been previously identified in S. typhimurium. In this study, we isolated transposon insertions in the genes for the two unique enzymes of this pathway, aceA (isocitrate lyase) and aceB (malate synthase). The aceA and aceB genes were located at 89.5 min on the S. typhimurium genetic map. Genetic linkage to nearby loci indi...

  2. Balancing the carbon flux distributions between the TCA cycle and glyoxylate shunt to produce glycolate at high yield and titer in Escherichia coli.

    Science.gov (United States)

    Deng, Yu; Ma, Ning; Zhu, Kangjia; Mao, Yin; Wei, Xuetuan; Zhao, Yunying

    2018-03-01

    The glyoxylate shunt is a branch of the tricarboxylic acid (TCA) cycle which directly determines the synthesis of glycolate, and the balance between the glyoxylate shunt and TCA cycle is very important for the growth of Escherichia coli. In order to accumulate glycolate at high yield and titer, strategies for over-expressing glycolate pathway enzymes including isocitrate lyase (AceA), isocitrate dehydrogenase kinase/phosphatase (AceK) and glyoxylate reductase (YcdW) were analyzed. The genes encoding these three enzymes were transcribed under the control of promoter pTrc on pTrc99A, to form pJNU-3, which was harbored by strain Mgly1, resulting in strain Mgly13. Strain Mgly13 produced glycolate with 0.385 g/g-glucose yield (45.2% of the theoretical yield). Citrate synthase (GltA) converted excess acetyl-CoA and oxaloacetate to citrate and was over-expressed by pJNU-4 (pCDFDuet-1 backbone). Thus, the resulting strain Mgly134 produced glycolate with a 0.504 g/g-glucose yield (59.3% of the theoretical yield). We then eliminated the pathways involved in the degradation of glycolate, resulting in strain Mgly434, which produced glycolate with 92.9% of the theoretical yield. Following optimization of fermentation, the maximum glycolate titer from strain Mgly434 was 65.5 g/L. Copyright © 2018 International Metabolic Engineering Society. Published by Elsevier Inc. All rights reserved.

  3. Serine:glyoxylate aminotransferase mutant of barley

    International Nuclear Information System (INIS)

    Blackwell, R.; Murray, A.; Joy, K.; Lea, P.

    1987-01-01

    A photorespiratory mutant of barley (LaPr 85/84), deficient in both of the major peaks of serine:glyoxylate aminotransferase activity detected in the wild type, also lacks serine:pyruvate and asparagine:glyoxylate aminotransferase activities. Genetic analysis of the mutation demonstrated that these three activities are all carried on the same enzyme. The mutant, when placed in air, accumulated a large pool of serine, showed the expected rate (50%) of ammonia release during photorespiration but produced CO 2 at twice the wild type rate when it was fed [ 14 C] glyoxylate. Compared with the wild type, LaPr 85/84 exhibited abnormal transient changes in chlorophyll a fluorescence when the CO 2 concentration of the air was altered, indicating that the rates of the fluorescence quenching mechanisms were affected in vivo by the lack of this enzyme

  4. Increasing L-threonine production in Escherichia coli by engineering the glyoxylate shunt and the L-threonine biosynthesis pathway.

    Science.gov (United States)

    Zhao, Hui; Fang, Yu; Wang, Xiaoyuan; Zhao, Lei; Wang, Jianli; Li, Ye

    2018-04-30

    L-threonine is an important amino acid that can be added in food, medicine, or feed. Here, the influence of glyoxylate shunt on an L-threonine producing strain Escherichia coli TWF001 has been studied. The gene iclR was deleted, and the native promoter of the aceBA operon was replaced by the trc promoter in the chromosome of TWF001, the resulting strainTWF004 could produce 0.39 g L-threonine from1 g glucose after 36-h flask cultivation. Further replacing the native promoter of aspC by the trc promoter in the chromosome of TWF004 resulted in the strain TWF006. TWF006 could produce 0.42 g L-threonine from 1 g glucose after 36-h flask cultivation. Three key genes in the biosynthetic pathway of L-threonine, thrA * (a mutated thrA), thrB, and thrC were overexpressed in TWF006, resulting the strain TWF006/pFW01-thrA * BC. TWF006/pFW01-thrA * BC could produce 0.49 g L-threonine from 1 g glucose after 36-h flask cultivation. Next, the genes asd, rhtA, rhtC, or thrE were inserted into the plasmid TWF006/pFW01-thrA * BC, and TWF006 was transformed with these plasmids, resulting the strains TWF006/pFW01-thrA * BC-asd, TWF006/pFW01-thrA * BC-rhtA, TWF006/pFW01-thrA * BC-rhtC, and TWF006/pFW01-thrA * BC-thrE, respectively. These four strains could produce more L-threonine than the control strain, and the highest yield was produced by TWF006/pFW01-thrA * BC-asd; after 36-h flask cultivation, TWF006/pFW01-thrA * BC-asd could produce 15.85 g/l L-threonine, i.e., 0.53 g L-threonine per 1 g glucose, which is a 70% increase relative to the control strain TWF001. The results suggested that the combined engineering of glyoxylate shunt and L-threonine biosynthesis pathway could significantly increase the L-threonine production in E. coli.

  5. Biochemical Validation of the Glyoxylate Cycle in the Cyanobacterium Chlorogloeopsis fritschii Strain PCC 9212.

    Science.gov (United States)

    Zhang, Shuyi; Bryant, Donald A

    2015-05-29

    Cyanobacteria are important photoautotrophic bacteria with extensive but variable metabolic capacities. The existence of the glyoxylate cycle, a variant of the TCA cycle, is still poorly documented in cyanobacteria. Previous studies reported the activities of isocitrate lyase and malate synthase, the key enzymes of the glyoxylate cycle in some cyanobacteria, but other studies concluded that these enzymes are missing. In this study the genes encoding isocitrate lyase and malate synthase from Chlorogloeopsis fritschii PCC 9212 were identified, and the recombinant enzymes were biochemically characterized. Consistent with the presence of the enzymes of the glyoxylate cycle, C. fritschii could assimilate acetate under both light and dark growth conditions. Transcript abundances for isocitrate lyase and malate synthase increased, and C. fritschii grew faster, when the growth medium was supplemented with acetate. Adding acetate to the growth medium also increased the yield of poly-3-hydroxybutyrate. When the genes encoding isocitrate lyase and malate synthase were expressed in Synechococcus sp. PCC 7002, the acetate assimilation capacity of the resulting strain was greater than that of wild type. Database searches showed that the genes for the glyoxylate cycle exist in only a few other cyanobacteria, all of which are able to fix nitrogen. This study demonstrates that the glyoxylate cycle exists in a few cyanobacteria, and that this pathway plays an important role in the assimilation of acetate for growth in one of those organisms. The glyoxylate cycle might play a role in coordinating carbon and nitrogen metabolism under conditions of nitrogen fixation. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.

  6. Protein Homeostasis Defects of Alanine-Glyoxylate Aminotransferase: New Therapeutic Strategies in Primary Hyperoxaluria Type I

    Directory of Open Access Journals (Sweden)

    Angel L. Pey

    2013-01-01

    Full Text Available Alanine-glyoxylate aminotransferase catalyzes the transamination between L-alanine and glyoxylate to produce pyruvate and glycine using pyridoxal 5′-phosphate (PLP as cofactor. Human alanine-glyoxylate aminotransferase is a peroxisomal enzyme expressed in the hepatocytes, the main site of glyoxylate detoxification. Its deficit causes primary hyperoxaluria type I, a rare but severe inborn error of metabolism. Single amino acid changes are the main type of mutation causing this disease, and considerable effort has been dedicated to the understanding of the molecular consequences of such missense mutations. In this review, we summarize the role of protein homeostasis in the basic mechanisms of primary hyperoxaluria. Intrinsic physicochemical properties of polypeptide chains such as thermodynamic stability, folding, unfolding, and misfolding rates as well as the interaction of different folding states with protein homeostasis networks are essential to understand this disease. The view presented has important implications for the development of new therapeutic strategies based on targeting specific elements of alanine-glyoxylate aminotransferase homeostasis.

  7. Neuroprotection of ebselen against ischemia/reperfusion injury involves GABA shunt enzymes.

    Science.gov (United States)

    Seo, Jeong Yeol; Lee, Choong Hyun; Cho, Jun Hwi; Choi, Jung Hoon; Yoo, Ki-Yeon; Kim, Dae Won; Park, Ok Kyu; Li, Hua; Choi, Soo Young; Hwang, In Koo; Won, Moo-Ho

    2009-10-15

    Seleno-organic compound, ebselen (2-phenyl-1,2-benzisoselenazol-3(2H)-one), is a substrate with radical-scavenging activity. In this study, we observed the neuroprotective effects of ebselen against ischemic damage and on GABA shunt enzymes such as glutamic acid decarboxylase 67 (GAD67), GABA transaminse (GABA-T) and succinic semialdehyde dehydrogenase (SSADH) in the hippocampal CA1 region after 5 min of transient forebrain ischemia in gerbils. For this, vehicle (physiological saline) or ebselen was administered 30 min before or after ischemia/reperfusion and sacrificed 4 days after ischemia/reperfusion. The administration of ebselen significantly reduced the neuronal death in the CA1 region induced by ischemia/reperfusion. In addition, treatment with ebselen markedly elevated GAD67, GABA-T and SSADH immunoreactivity and their protein levels compared to that in the vehicle-treated group, respectively. These results suggest that ebselen protects neurons from ischemic damage via control of the expressions of GABA shunt enzymes to enter the TCA cycle.

  8. Inhibitors of the glyoxylate cycle enzyme ICL1 in Candida albicans for potential use as antifungal agents.

    Directory of Open Access Journals (Sweden)

    Hong-Leong Cheah

    Full Text Available Candida albicans is an opportunistic pathogen that causes candidiasis in humans. In recent years, metabolic pathways in C. albicans have been explored as potential antifungal targets to treat candidiasis. The glyoxylate cycle, which enables C. albicans to survive in nutrient-limited host niches and its. Key enzymes (e.g., isocitrate lyase (ICL1, are particularly attractive antifungal targets for C. albicans. In this study, we used a new screening approach that better reflects the physiological environment that C. albicans cells experience during infection to identify potential inhibitors of ICL. Three compounds (caffeic acid (CAFF, rosmarinic acid (ROS, and apigenin (API were found to have antifungal activity against C. albicans when tested under glucose-depleted conditions. We further confirmed the inhibitory potential of these compounds against ICL using the ICL enzyme assay. Lastly, we assessed the bioavailability and toxicity of these compounds using Lipinski's rule-of-five and ADMET analysis.

  9. Contribution of the tricarboxylic acid (TCA) cycle and the glyoxylate shunt in Saccharomyces cerevisiae to succinic acid production during dough fermentation.

    Science.gov (United States)

    Rezaei, Mohammad N; Aslankoohi, Elham; Verstrepen, Kevin J; Courtin, Christophe M

    2015-07-02

    Succinic acid produced by yeast during bread dough fermentation can significantly affect the rheological properties of the dough. By introducing mutations in the model S288C yeast strain, we show that the oxidative pathway of the TCA cycle and the glyoxylate shunt contribute significantly to succinic acid production during dough fermentation. More specifically, deletion of ACO1 and double deletion of ACO1 and ICL1 resulted in a 36 and 77% decrease in succinic acid levels in fermented dough, respectively. Similarly, double deletion of IDH1 and IDP1 decreased succinic acid production by 85%, while also affecting the fermentation rate. By contrast, double deletion of SDH1 and SDH2 resulted in a two-fold higher succinic acid accumulation compared to the wild-type. Deletion of fumarate reductase activity (FRD1 and OSM1) in the reductive pathway of the TCA cycle did not affect the fermentation rate and succinic acid production. The changes in the levels of succinic acid produced by mutants Δidh1Δidp1 (low level) and Δsdh1Δsdh2 (high level) in fermented dough only resulted in small pH differences, reflecting the buffering capacity of dough at a pH of around 5.1. Moreover, Rheofermentometer analysis using these mutants revealed no difference in maximum dough height and gas retention capacity with the dough prepared with S288C. The impact of the changed succinic acid profile on the organoleptic or antimicrobial properties of bread remains to be demonstrated. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Glyoxylate, a New Marker Metabolite of Type 2 Diabetes

    Science.gov (United States)

    Nikiforova, Victoria J.; Giesbertz, Pieter; Wiemer, Jan; Bethan, Bianca; Looser, Ralf; Liebenberg, Volker; Ruiz Noppinger, Patricia; Daniel, Hannelore; Rein, Dietrich

    2014-01-01

    Type 2 diabetes (T2D) is characterized by a variety of metabolic impairments that are closely linked to nonenzymatic glycation reactions of proteins and peptides resulting in advanced glycation end-products (AGEs). Reactive aldehydes derived from sugars play an important role in the generation of AGEs. Using metabolite profiling to characterize human plasma from diabetic versus nondiabetic subjects we observed in a recent study that the reactive aldehyde glyoxylate was increased before high levels of plasma glucose, typical for a diabetic condition, could be measured. Following this observation, we explored the relevance of increased glyoxylate in diabetic subjects and in diabetic C57BLKS/J-Leprdb/db−/− mice in the pathophysiology of diabetes. A retrospective study using samples of long-term blood donors revealed that glyoxylate levels unlike glucose levels became significantly elevated up to 3 years prior to diabetes diagnosis (difference to control P = 0.034). Elevated glyoxylate levels impact on newly identified mechanisms linking hyperglycemia and AGE production with diabetes-associated complications such as diabetic nephropathy. Glyoxylate in its metabolic network may serve as an early marker in diabetes diagnosis with predictive qualities for associated complications and as potential to guide the development of new antidiabetic therapies. PMID:25525609

  11. Characterization of recombinant glyoxylate reductase from thermophile Thermus thermophilus HB27.

    Science.gov (United States)

    Ogino, Hiroyasu; Nakayama, Hitoshi; China, Hideyasu; Kawata, Takuya; Doukyu, Noriyuki; Yasuda, Masahiro

    2008-01-01

    A glyoxylate reductase gene from the thermophilic bacterium Thermus thermophilus HB27 (TthGR) was cloned and expressed in Escherichia coli cells. The recombinant enzyme was highly purified to homogeneity and characterized. The purified TthGR showed thermostability up to 70 degrees C. In contrast, the maximum reaction condition was relatively mild (45 degrees C and pH 6.7). Although the kcat values against co-enzyme NADH and NADPH were similar, the Km value against co-enzyme NADH was approximately 18 times higher than that against NADPH. TthGR prefers NADPH rather than NADH as an electron donor. These results indicate that a phosphate group of a co-enzyme affects the binding affinity rather than the reaction efficiency, and TthGR demands appropriate amount of phosphate for a high activity. Furthermore, it was found that the half-lives of TthGR in the presence of 25% dimethyl sulfoxide and diethylene glycol were significantly longer than that in the absence of an organic solvent.

  12. Allele-specific characterization of alanine: glyoxylate aminotransferase variants associated with primary hyperoxaluria.

    Directory of Open Access Journals (Sweden)

    Melissa D Lage

    Full Text Available Primary Hyperoxaluria Type 1 (PH1 is a rare autosomal recessive kidney stone disease caused by deficiency of the peroxisomal enzyme alanine: glyoxylate aminotransferase (AGT, which is involved in glyoxylate detoxification. Over 75 different missense mutations in AGT have been found associated with PH1. While some of the mutations have been found to affect enzyme activity, stability, and/or localization, approximately half of these mutations are completely uncharacterized. In this study, we sought to systematically characterize AGT missense mutations associated with PH1. To facilitate analysis, we used two high-throughput yeast-based assays: one that assesses AGT specific activity, and one that assesses protein stability. Approximately 30% of PH1-associated missense mutations are found in conjunction with a minor allele polymorphic variant, which can interact to elicit complex effects on protein stability and trafficking. To better understand this allele interaction, we functionally characterized each of 34 mutants on both the major (wild-type and minor allele backgrounds, identifying mutations that synergize with the minor allele. We classify these mutants into four distinct categories depending on activity/stability results in the different alleles. Twelve mutants were found to display reduced activity in combination with the minor allele, compared with the major allele background. When mapped on the AGT dimer structure, these mutants reveal localized regions of the protein that appear particularly sensitive to interactions with the minor allele variant. While the majority of the deleterious effects on activity in the minor allele can be attributed to synergistic interaction affecting protein stability, we identify one mutation, E274D, that appears to specifically affect activity when in combination with the minor allele.

  13. Electrostatic interactions drive native-like aggregation of human alanine:glyoxylate aminostransferase.

    Science.gov (United States)

    Dindo, Mirco; Conter, Carolina; Cellini, Barbara

    2017-11-01

    Protein aggregate formation is the basis of several misfolding diseases, including those displaying loss-of-function pathogenesis. Although aggregation is often attributed to the population of intermediates exposing hydrophobic surfaces, the contribution of electrostatic forces has recently gained attention. Here, we combined computational and in vitro studies to investigate the aggregation process of human peroxisomal alanine:glyoxylate aminotransferase (AGT), a pyridoxal 5'-phosphate (PLP)-dependent enzyme involved in glyoxylate detoxification. We demonstrated that AGT is susceptible to electrostatic aggregation due to its peculiar surface charge anisotropy and that PLP binding counteracts the self-association process. The two polymorphic mutations P11L and I340M exert opposite effects. The P11L substitution enhances the aggregation tendency, probably by increasing surface charge anisotropy, while I340M plays a stabilizing role. In light of these results, we examined the effects of the most common missense mutations leading to primary hyperoxaluria type I (PH1), a rare genetic disorder associated with abnormal calcium oxalate precipitation in the urinary tract. All of them endow AGT with a strong electrostatic aggregation propensity. Moreover, we predicted that pathogenic mutations of surface residues could alter charge distribution, thus inducing aggregation under physiological conditions. A global model describing the AGT aggregation process is provided. Overall, the results indicate that the contribution of electrostatic interactions in determining the fate of proteins and the effect of amino acid substitutions should not be underestimated and provide the basis for the development of new therapeutic strategies for PH1 aimed at increasing AGT stability. © 2017 Federation of European Biochemical Societies.

  14. Investigation on the Metabolic Regulation of pgi gene knockout Escherichia coli by Enzyme Activities and Intracellular Metabolite Concentrations

    Directory of Open Access Journals (Sweden)

    Nor ‘Aini, A. R.

    2006-01-01

    Full Text Available An integrated analysis of the cell growth characteristics, enzyme activities, intracellular metabolite concentrations was made to investigate the metabolic regulation of pgi gene knockout Escherichia coli based on batch culture and continuous culture which was performed at the dilution rate of 0.2h-1. The enzymatic study identified that pathways of pentose phosphate, ED pathway and glyoxylate shunt were all active in pgi mutant. The glycolysis enzymes i.e glyceraldehyde-3-phosphate dehydrogenase, fructose diphosphatase, pyruvate kinase, triose phosphate isomerase were down regulated implying that the inactivation of pgi gene reduced the carbon flux through glycolytic pathway. Meanwhile, the pentose phosphate pathway was active as a major route for intermediary carbohydrate metabolism instead of glycolysis. The pentose phosphate pathway generates most of the major reducing co-factor NADPH as shown by the increased of NADPH/NADP+ ratio in the mutant when compared with the parent strain. The fermentative enzymes such as acetate kinase and lactate dehydrogenase were down regulated in the mutant. Knockout of pgi gene results in the significant increase in the intracellular concentration of glucose-6-phosphate and decrease in the concentration of oxaloacetate. The slow growth rate of the mutant was assumed to be affected by the accumulation of glucose-6-phosphate and imbalance of NADPH reoxidation.

  15. Phenotypic and chemotypic characterization of GABA-shunt mutants in Arabidopsis thaliana

    OpenAIRE

    Mekonnen, Dereje Worku

    2013-01-01

    Gamma-Aminobutyric acid (GABA) is a four carbon non protein amino acid, and the pathway that involves its production and degradation is called the GABA shunt. The GABA shunt is a short enzymatic pathway that involves three enzymes: glutamate decarboxylase (GAD), GABA transaminase (GABA-T) and succinic semi aldehyde dehydrogenase (SSADH). GABA shunt is conserved almost in all organisms studied so far. The pathway starts in the cytosol and finishes in mitochondria in higher organisms like plant...

  16. Microbial growth on oxalate by a route not involving glyoxylate carboligase

    Science.gov (United States)

    Blackmore, Maureen A.; Quayle, J. R.

    1970-01-01

    1. The metabolism of oxalate by the pink-pigmented organisms, Pseudomonas AM1, Pseudomonas AM2, Protaminobacter ruber and Pseudomonas extorquens has been compared with that of the non-pigmented Pseudomonas oxalaticus. 2. During growth on oxalate, all the organisms contain oxalyl-CoA decarboxylase, formate dehydrogenase and oxalyl-CoA reductase. This is consistent with oxidation of oxalate to carbon dioxide taking place via oxalyl-CoA, formyl-CoA and formate as intermediates, and also reduction of oxalate to glyoxylate taking place via oxalyl-CoA. 3. The pink-pigmented organisms, when grown on oxalate, contain l-serine–glyoxylate aminotransferase and hydroxypyruvate reductase but do not contain glyoxylate carboligase. The converse of this obtains in oxalate-grown Ps. oxalaticus. This indicates that, in contrast with Ps. oxalaticus, synthesis of C3 compounds from oxalate by the pink-pigmented organisms occurs by a variant of the `serine pathway' used by Pseudomonas AM1 during growth on C1 compounds. 4. Evidence in favour of this scheme is provided by the finding that a mutant of Pseudomonas AM1 that lacks hydroxypyruvate reductase is not able to grow on oxalate. PMID:5472155

  17. Malate and fumarate extend lifespan in Caenorhabditis elegans.

    Directory of Open Access Journals (Sweden)

    Clare B Edwards

    Full Text Available Malate, the tricarboxylic acid (TCA cycle metabolite, increased lifespan and thermotolerance in the nematode C. elegans. Malate can be synthesized from fumarate by the enzyme fumarase and further oxidized to oxaloacetate by malate dehydrogenase with the accompanying reduction of NAD. Addition of fumarate also extended lifespan, but succinate addition did not, although all three intermediates activated nuclear translocation of the cytoprotective DAF-16/FOXO transcription factor and protected from paraquat-induced oxidative stress. The glyoxylate shunt, an anabolic pathway linked to lifespan extension in C. elegans, reversibly converts isocitrate and acetyl-CoA to succinate, malate, and CoA. The increased longevity provided by malate addition did not occur in fumarase (fum-1, glyoxylate shunt (gei-7, succinate dehydrogenase flavoprotein (sdha-2, or soluble fumarate reductase F48E8.3 RNAi knockdown worms. Therefore, to increase lifespan, malate must be first converted to fumarate, then fumarate must be reduced to succinate by soluble fumarate reductase and the mitochondrial electron transport chain complex II. Reduction of fumarate to succinate is coupled with the oxidation of FADH2 to FAD. Lifespan extension induced by malate depended upon the longevity regulators DAF-16 and SIR-2.1. Malate supplementation did not extend the lifespan of long-lived eat-2 mutant worms, a model of dietary restriction. Malate and fumarate addition increased oxygen consumption, but decreased ATP levels and mitochondrial membrane potential suggesting a mild uncoupling of oxidative phosphorylation. Malate also increased NADPH, NAD, and the NAD/NADH ratio. Fumarate reduction, glyoxylate shunt activity, and mild mitochondrial uncoupling likely contribute to the lifespan extension induced by malate and fumarate by increasing the amount of oxidized NAD and FAD cofactors.

  18. An engineered pathway for glyoxylate metabolism in tobacco plants aimed to avoid the release of ammonia in photorespiration

    Directory of Open Access Journals (Sweden)

    Carvalho Josirley de FC

    2011-11-01

    Full Text Available Abstract Background The photorespiratory nitrogen cycle in C3 plants involves an extensive diversion of carbon and nitrogen away from the direct pathways of assimilation. The liberated ammonia is re-assimilated, but up to 25% of the carbon may be released into the atmosphere as CO2. Because of the loss of CO2 and high energy costs, there has been considerable interest in attempts to decrease the flux through the cycle in C3 plants. Transgenic tobacco plants were generated that contained the genes gcl and hyi from E. coli encoding glyoxylate carboligase (EC 4.1.1.47 and hydroxypyruvate isomerase (EC 5.3.1.22 respectively, targeted to the peroxisomes. It was presumed that the two enzymes could work together and compete with the aminotransferases that convert glyoxylate to glycine, thus avoiding ammonia production in the photorespiratory nitrogen cycle. Results When grown in ambient air, but not in elevated CO2, the transgenic tobacco lines had a distinctive phenotype of necrotic lesions on the leaves. Three of the six lines chosen for a detailed study contained single copies of the gcl gene, two contained single copies of both the gcl and hyi genes and one line contained multiple copies of both gcl and hyi genes. The gcl protein was detected in the five transgenic lines containing single copies of the gcl gene but hyi protein was not detected in any of the transgenic lines. The content of soluble amino acids including glycine and serine, was generally increased in the transgenic lines growing in air, when compared to the wild type. The content of soluble sugars, glucose, fructose and sucrose in the shoot was decreased in transgenic lines growing in air, consistent with decreased carbon assimilation. Conclusions Tobacco plants have been generated that produce bacterial glyoxylate carboligase but not hydroxypyruvate isomerase. The transgenic plants exhibit a stress response when exposed to air, suggesting that some glyoxylate is diverted away from

  19. Subacute bacterial endocarditis and subsequent shunt nephritis from ventriculoatrial shunting 14 years after shunt implantation

    DEFF Research Database (Denmark)

    Burström, Gustav; Andresen, Morten; Bartek, Jiri Jr.

    2014-01-01

    of causing subacute bacterial endocarditis and subsequent shunt nephritis. The patient was successfully treated with antibiotics combined with ventriculoatrial shunt removal and endoscopic third ventriculocisternostomy (VCS). This case illustrates the nowadays rare, but potentially severe complication...... of subacute bacterial endocarditis and shunt nephritis. It also exemplifies the VCS as an alternative to implanting foreign shunt systems for CSF diversion....

  20. Phenylpropanoid 2,3-dioxygenase involved in the cleavage of the ferulic acid side chain to form vanillin and glyoxylic acid in Vanilla planifolia.

    Science.gov (United States)

    Negishi, Osamu; Negishi, Yukiko

    2017-09-01

    Enzyme catalyzing the cleavage of the phenylpropanoid side chain was partially purified by ion exchange and gel filtration column chromatography after (NH 4 ) 2 SO 4 precipitation. Enzyme activities were dependent on the concentration of dithiothreitol (DTT) or glutathione (GSH) and activated by addition of 0.5 mM Fe 2+ . Enzyme activity for ferulic acid was as high as for 4-coumaric acid in the presence of GSH, suggesting that GSH acts as an endogenous reductant in vanillin biosynthesis. Analyses of the enzymatic reaction products with quantitative NMR (qNMR) indicated that an amount of glyoxylic acid (GA) proportional to vanillin was released from ferulic acid by the enzymatic reaction. These results suggest that phenylpropanoid 2,3-dioxygenase is involved in the cleavage of the ferulic acid side chain to form vanillin and GA in Vanilla planifolia.

  1. Pancreaticoportal Fistula and Disseminated Fat Necrosis After Revision of a Transjugular Intrahepatic Portosystemic Shunt

    International Nuclear Information System (INIS)

    Klein, Seth J.; Saad, Nael; Korenblat, Kevin; Darcy, Michael D.

    2013-01-01

    A 59-year old man with alcohol related cirrhosis and portal hypertension was referred for transjugular intrahepatic portosystemic shunt (TIPS) to treat his refractory ascites. Ten years later, two sequential TIPS revisions were performed for shunt stenosis and recurrent ascites. After these revisions, he returned with increased serum pancreatic enzyme levels and disseminated superficial fat necrosis; an iatrogenic pancreaticoportal vein fistula caused by disruption of the pancreatic duct was suspected. The bare area of the TIPS was subsequently lined with a covered stent-graft, and serum enzyme levels returned to baseline. In the interval follow-up period, the patient has clinically improved.

  2. Pancreaticoportal Fistula and Disseminated Fat Necrosis After Revision of a Transjugular Intrahepatic Portosystemic Shunt

    Energy Technology Data Exchange (ETDEWEB)

    Klein, Seth J., E-mail: kleins@mir.wustl.edu; Saad, Nael [Washington University School of Medicine, Interventional Radiology Section, Mallinckrodt Institute of Radiology (United States); Korenblat, Kevin [Washington University School of Medicine, Division of Gastroenterology, Department of Internal Medicine (United States); Darcy, Michael D. [Washington University School of Medicine, Interventional Radiology Section, Mallinckrodt Institute of Radiology (United States)

    2013-04-15

    A 59-year old man with alcohol related cirrhosis and portal hypertension was referred for transjugular intrahepatic portosystemic shunt (TIPS) to treat his refractory ascites. Ten years later, two sequential TIPS revisions were performed for shunt stenosis and recurrent ascites. After these revisions, he returned with increased serum pancreatic enzyme levels and disseminated superficial fat necrosis; an iatrogenic pancreaticoportal vein fistula caused by disruption of the pancreatic duct was suspected. The bare area of the TIPS was subsequently lined with a covered stent-graft, and serum enzyme levels returned to baseline. In the interval follow-up period, the patient has clinically improved.

  3. Glyoxylic compounds as radiosensitizers of hypoxic cells

    International Nuclear Information System (INIS)

    Cornago, M.P.; Lopez Zumel, M.C.; Alvarez, M.V.; Izquierdo, M.C.

    1990-01-01

    The radiosensitizing effect of five glyoxal derivatives on the survival of TC-SV40 cells has been measured, under aerobic and hypoxic conditions. A toxicity study was previously performed in order to use nontoxic concentrations. The OER for the TC-SV40 cells was 2.74. None of the glyoxylic compounds showed radiosensitizing activity under aerobic conditions while in hypoxia their radiosensitizing factors decreased in the order phenylglyoxylic acid (1.68 at 8 x 10(-3) mole dm-3) greater than phenylglyoxal (1.55 at 5 x 10(-6) mole dm-3) greater than 2-2' furil (1.48 at 5 x 10(-5) mole dm-3) greater than glyoxylic acid (1.39 at 1 x 10(-3) mole dm-3) greater than glyoxal (1.30 at 5 x 10(-5) mole dm-3). The dose-modifying factors were also determined at two equimolar concentrations 5 x 10(-5) and 5 x 10(-6) mole dm-3. A concentration effect was noticed for all the compounds although their relative radiosensitizing activity kept, independently of the concentration, the same order noted above. Glyoxals with aromatic or heterocyclic rings exert a greater radiosensitization than the others. The acidic compounds have less radiosensitizing activity than their aldehydic counterparts. Interaction of these glyoxals with NPSH cellular groups was tested and the low degree of inhibition shows that this mechanism would contribute very little, if any, to the radiosensitization effect

  4. Ventriculoperitoneal Shunt Migration

    Directory of Open Access Journals (Sweden)

    Justin P Puller

    2017-01-01

    Full Text Available History of present illness: A 40-year-old female presented to our ED with left upper abdominal pain and flank pain. The pain had begun suddenly 2 hours prior when she was reaching into a freezer to get a bag of frozen vegetables. She described the pain as sharp, constant, severe, and worse with movements and breathing. The pain radiated to the left shoulder. On review of systems, the patient had mild dyspnea and nausea. She denied fever, chills, headache, vision changes, vomiting, or urinary symptoms. Her medical history was notable for obstructive sleep apnea, gastroesophageal reflux disease, arthritis, fibromyalgia, depression, obesity, and idiopathic intracranial hypertension. For the latter, she had a VP (ventriculoperitoneal shunt placed 14 years prior to this visit. She had a history of 2 shunt revisions, the most recent 30 days before this ED visit. Significant findings: An immediate post-op abdominal x-ray performed after the patient’s VP shunt revision 30 days prior to this ED visit reveals the VP shunt tip in the mid abdomen. A CT of the abdomen performed on the day of the ED visit reveals the VP shunt tip interposed between the spleen and the diaphragm. Discussion: VP shunts have been reported to migrate to varied locations in the thorax and abdomen. Incidence of abdominal complications of VP shunt placement ranges from 10%-30%, and can include pseudocyst formation, migration, peritonitis, CSF ascites, infection, and viscus perforation. Incidence of distal shunt migration is reported as 10%, and most previously reported cases occurred in pediatric patients.1 A recent retrospective review cited BMI greater than thirty and previous shunt procedure as risk factors for distal shunt migration.2 The patient in the case presented had a BMI of 59 and 3 previous shunt procedures.

  5. Metal-catalyzed Asymmetric Hetero-Diels-Alder Reactions of Unactivated Dienes with Glyoxylates

    DEFF Research Database (Denmark)

    Johannsen, Mogens; Yao, Sulan; Graven, Anette

    1998-01-01

    The development of a catalytic asymmetric hetero-Diels-Alder methodology for the reaction of unactivated dienes with glyoxylates is presented. Several different asymmetric catalysts can be used, but copper-bisoxazolines and aluminium-BINOL give the highest yield, and the best chemo...

  6. Pathophysiology of shunt dysfunction in shunt treated hydrocephalus

    DEFF Research Database (Denmark)

    Blegvad, C.; Skjolding, A D; Broholm, H

    2013-01-01

    We hypothesized that shunt dysfunction in the ventricular catheter and the shunt valve is caused by different cellular responses. We also hypothesized that the cellular responses depend on different pathophysiological mechanisms....

  7. Idiopathic intracranial hypertension: lumboperitoneal shunts versus ventriculoperitoneal shunts--case series and literature review.

    LENUS (Irish Health Repository)

    Abubaker, Khalid

    2012-02-01

    OBJECTIVES: Idiopathic intracranial hypertension (IIH) is an uncommon but important cause of headache that can lead to visual loss. This study was undertaken to review our experience in the treatment of IIH by neuronavigation-assisted ventriculoperitoneal (VP) shunts with programmable valves as compared to lumboperitoneal (LP) shunts. METHODS: A retrospective chart review was conducted on 25 patients treated for IIH between 2001 and 2009. Age, sex, clinical presentation, methods of treatment and failure rates were recorded. RESULTS: Seventy-two per cent were treated initially with LP shunts. Failure rate was 11% in this group. Neuronavigation-assisted VP shunts were used to treat 28%. In this group, the failure rate was 14%. CONCLUSION: Our experience indicates that both LP shunts and VP shuts are effective in controlling all the clinical manifestations of IIH in the immediate postoperative period. Failure rates are slightly higher for VP shunts (14%) than LP shunts (11%). However, revision rates are higher with LP shunts (60%) than with VP shunts (30%).

  8. Solvent Isotope-induced Equilibrium Perturbation for Isocitrate Lyase

    Science.gov (United States)

    Quartararo, Christine E.; Hadi, Timin; Cahill, Sean M.; Blanchard, John S.

    2014-01-01

    Isocitrate lyase (ICL) catalyzes the reversible retro-aldol cleavage of isocitrate to generate glyoxylate and succinate. ICL is the first enzyme of the glyoxylate shunt, which allows for the anaplerosis of citric acid cycle intermediates under nutrient limiting conditions. In Mycobacterium tuberculosis, the source of ICL for these studies, ICL is vital for the persistence phase of the bacteria’s life cycle. Solvent kinetic isotope effects (KIEs) in the direction of isocitrate cleavage of D2OV = 2.0 ± 0.1 and D2O[V/Kisocitrate] = 2.2 ± 0.3 arise from the initial deprotonation of the C2 hydroxyl group of isocitrate or the protonation of the aci-acid of succinate product of the isocitrate aldol cleavage by a solvent-derived proton. This KIE suggested that an equilibrium mixture of all protiated isocitrate, glyoxylate and succinate prepared in D2O, would undergo transient changes in equilibrium concentrations as a result of the solvent KIE and solvent-derived deuterium incorporation into both succinate and isocitrate. No change in the isotopic composition of glyoxylate was expected or observed. We have directly monitored the changing concentrations of all isotopic species of all reactants and products using a combination of NMR spectroscopy and mass spectrometry. Continuous monitoring of glyoxylate by 1H NMR spectroscopy shows a clear equilibrium perturbation in D2O. The final equilibrium isotopic composition of reactants in D2O revealed di-deuterated succinate, protiated glyoxylate, and mono-deuterated isocitrate, with the transient appearance and disappearance of mono-deuterated succinate. A model for the equilibrium perturbation of substrate species, and their time-dependent isotopic composition is presented. PMID:24261638

  9. Hypoxia and GABA shunt activation in the pathogenesis of Alzheimer's disease.

    Science.gov (United States)

    Salminen, Antero; Jouhten, Paula; Sarajärvi, Timo; Haapasalo, Annakaisa; Hiltunen, Mikko

    2016-01-01

    We have previously observed that the conversion of mild cognitive impairment to definitive Alzheimer's disease (AD) is associated with a significant increase in the serum level of 2,4-dihydroxybutyrate (2,4-DHBA). The metabolic generation of 2,4-DHBA is linked to the activation of the γ-aminobutyric acid (GABA) shunt, an alternative energy production pathway activated during cellular stress, when the function of Krebs cycle is compromised. The GABA shunt can be triggered by local hypoperfusion and subsequent hypoxia in AD brains caused by cerebral amyloid angiopathy. Succinic semialdehyde dehydrogenase (SSADH) is a key enzyme in the GABA shunt, converting succinic semialdehyde (SSA) into succinate, a Krebs cycle intermediate. A deficiency of SSADH activity stimulates the conversion of SSA into γ-hydroxybutyrate (GHB), an alternative route from the GABA shunt. GHB can exert not only acute neuroprotective activities but unfortunately also chronic detrimental effects which may lead to cognitive impairment. Subsequently, GHB can be metabolized to 2,4-DHBA and secreted from the brain. Thus, the activation of the GABA shunt and the generation of GHB and 2,4-DHBA can have an important role in the early phase of AD pathogenesis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Regulation of flux through metabolic cycles

    International Nuclear Information System (INIS)

    Walsh, K.

    1984-01-01

    The branchpoint of the tricarboxylic acid and glyoxylate shunt was characterized in the intact organism by a multidimensional approach. Theory and methodology were developed to determine velocities for the net flow of carbon through the major steps of acetate metabolism in E. coli. Rates were assigned based on the 13 C-NMR spectrum of intracellular glutamate, measured rates of substrate incorporation into end products, the constituent composition of E. coli and a series of conservation equations which described the system at steady state. The in vivo fluxes through the branchpoint of the tricarboxylic acid and glyoxylate cycles were compared to rates calculated from the kinetic constants of the branchpoint enzymes and the intracellular concentrations of their substrates. These studies elucidated the role of isocitrate dehydrogenase phosphorylation in the Krebs cycle and led to the development of a generalized mathematical description of the sensitivity of branchpoints to regulatory control. This theoretical analysis was termed the branchpoint effect and it describes conditions which result in large changes in the flux through an enzyme even though that enzyme is not subject to direct regulatory control. The theoretical and experimental characterization of this system provided a framework to study the effects of enzyme overproduction and underproduction on metabolic processes in the cell. An in vivo method was developed to determine the extent to which an enzyme catalyzes a rate-controlling reaction. The enzyme chosen for this study was citrate synthase

  11. Ventriculo-pleural shunt patency study

    International Nuclear Information System (INIS)

    Yeates, K.

    2000-01-01

    Full text: A twenty-four year old male was admitted to hospital complaining of headaches, drowsiness and blurred vision. He suffered from congenital hydrocephalus and had had a ventriculo-peritoneal shunt inserted in infancy. This had undergone many revisions due to persistent peritoneal infections and had recently been replaced with a ventriculo-pleural shunt. The symptoms described suggested shunt blockage and he was referred for a Shunt Patency Study. The current shunt is a HAKIM Programmable Valve Shunt System and the opening pressure was 12cm of CSF (within the normal range). Forty megabecquerels of filtered 99 Tc m O 4 was injected into the pre-chamber of the shunt. Serial images and counts were obtained for twenty-five minutes after the injection. The images showed the tracer flowing from the shunt within the first ten minutes. At twenty minutes almost all of the tracer had drained from the shunt and was present in the right pleural cavity, indicating shunt patency. This study is presented to demonstrate the appearances of a normally functioning, but rarely seen Ventriculo-Pleural CSF Shunt. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  12. [Shunt and short circuit].

    Science.gov (United States)

    Rangel-Abundis, Alberto

    2006-01-01

    Shunt and short circuit are antonyms. In French, the term shunt has been adopted to denote the alternative pathway of blood flow. However, in French, as well as in Spanish, the word short circuit (court-circuit and cortocircuito) is synonymous with shunt, giving rise to a linguistic and scientific inconsistency. Scientific because shunt and short circuit made reference to a phenomenon that occurs in the field of the physics. Because shunt and short circuit are antonyms, it is necessary to clarify that shunt is an alternative pathway of flow from a net of high resistance to a net of low resistance, maintaining the stream. Short circuit is the interruption of the flow, because a high resistance impeaches the flood. This concept is applied to electrical and cardiovascular physiology, as well as to the metabolic pathways.

  13. Primary ventriculoperitoneal shunting outcomes: a multicentre clinical audit for shunt infection and its risk factors.

    Science.gov (United States)

    Woo, P Ym; Wong, H T; Pu, J Ks; Wong, W K; Wong, L Yw; Lee, M Wy; Yam, K Y; Lui, W M; Poon, W S

    2016-10-01

    To determine the frequency of primary ventriculoperitoneal shunt infection among patients treated at neurosurgical centres of the Hospital Authority and to identify underlying risk factors. This multicentre historical cohort study included consecutive patients who underwent primary ventriculoperitoneal shunting at a Hospital Authority neurosurgery centre from 1 January 2009 to 31 December 2011. The primary endpoint was shunt infection, defined as: (1) the presence of cerebrospinal fluid or shunt hardware culture that yielded the pathogenic micro-organism with associated compatible symptoms and signs of central nervous system infection or shunt malfunction; or (2) surgical incision site infection requiring shunt reinsertion (even in the absence of positive culture); or (3) intraperitoneal pseudocyst formation (even in the absence of positive culture). Secondary endpoints were shunt malfunction, defined as unsatisfactory cerebrospinal fluid drainage that required shunt reinsertion, and 30-day mortality. A primary ventriculoperitoneal shunt was inserted in 538 patients during the study period. The mean age of patients was 48 years (range, 13-88 years) with a male-to-female ratio of 1:1. Aneurysmal subarachnoid haemorrhage was the most common aetiology (n=169, 31%) followed by intracranial tumour (n=164, 30%), central nervous system infection (n=42, 8%), and traumatic brain injury (n=27, 5%). The mean operating time was 75 (standard deviation, 29) minutes. Shunt reinsertion and infection rates were 16% (n=87) and 7% (n=36), respectively. The most common cause for shunt reinsertion was malfunction followed by shunt infection. Independent predictors for shunt infection were: traumatic brain injury (adjusted odds ratio=6.2; 95% confidence interval, 2.3-16.8), emergency shunting (2.3; 1.0-5.1), and prophylactic vancomycin as the sole antibiotic (3.4; 1.1-11.0). The 30-day all-cause mortality was 6% and none were directly procedure-related. This is the first Hong Kong

  14. Ventriculoperitoneal shunt complications needing shunt revision in children: A review of 5 years of experience with 48 revisions

    Directory of Open Access Journals (Sweden)

    Rajendra K Ghritlaharey

    2012-01-01

    Full Text Available Background: The aim of this study was to review the management of ventriculoperitoneal (VP shunt complications in children. Patients and Methods: During the last 5 years (January 1, 2006 to December 31, 2010, 236 VP shunt operations were performed in children under 12 years of age; of these, 40 (16.94% developed shunt complications and those who underwent VP shunt revisions were studied. Results: This prospective study included 40 (28 boys and 12 girls children and required 48 shunt revisions. Complications following VP shunts that required shunt revisions were peritoneal catheter/peritoneal end malfunction (18, shunt/shunt tract infections (7, extrusion of peritoneal catheter through anus (5, ventricular catheter malfunction (4, cerebrospinal fluid (CSF leak from abdominal wound (4, shunt system failure (2, ventricular end/shunt displacement (2, CSF pseudocysts peritoneal cavity (2, extrusion of peritoneal catheter from neck, chest, abdominal scar and through umbilicus, one each. Four-fifth of these shunt complications occurred within 6 months of previous surgery. Surgical procedures done during shunt revisions in order of frequency were revision of peritoneal part of shunt (27, 56.25%, revision of entire shunt system (6, 12.5%, extra ventricular drainage and delayed re-shunt (5, 10.41%, shunt removal and delayed re-shunt (5, 10.41%, opposite side shunting (2, 4.16%, cysts excision and revision of peritoneal catheter (2, 4.16% and revision of ventricular catheter (1, 2.08%. The mortalities following VP shunt operations were 44 (18.64% and following shunt revisions were 4 (10%. Conclusions: VP shunt done for hydrocephalus in children is not only prone for complications and need for revision surgery but also associated with considerable mortality.

  15. Ventriculoperitoneal shunt blockage by hydatid cyst

    Directory of Open Access Journals (Sweden)

    Abrar A Wani

    2013-01-01

    Full Text Available Ventriculoperitoneal (VP shunt is one of the commonest procedures done in neurosurgical practice throughout the world. One of the commonest problems after putting the VP shunt is the shunt obstruction, which can be due to varied causes. Shunt obstruction secondary to the parasitic infections is rarely seen. We are presenting a 15-year-old child, a case of operated cerebral hydatid cyst with hydrocephalus. She presented with shunt malfunction after 1 year of surgical excision of the hydatid cyst. Revision of the VP shunt was done and peroperatively, it was found that the shunt tubing was obstructed due to small hydatid cysts. This is the first reported case of VP shunt obstruction by hydatid cyst.

  16. Delayed effects of radiation on enzymes in erythrocytes

    International Nuclear Information System (INIS)

    Li Jinying; Zhang Weiping; Liu Benti

    1998-01-01

    Objective: To study the delayed effects of radiation on the enzymes in erythrocytes. Methods: The activity of 8 enzymes, related glycolysis, hexose monophosphate shunt, nucleotide metabolism, redox reaction and esterase in erythrocytes of five patients with bone marrow form of acute radiation sickness (ARS) were assayed at 1,2,3 and 6 years after exposure to 60 Co radiation. Results: The decreased activities of glucose-6-phosphate dehydrogenase (G6PD), pyruvate kinase (PK), NADH-methemoglobin reductase (MR) during the stage of crisis and of acetylcholinesterase (ACE) during the stage of convalescence were recovered to varying extent, whereas the lowered activities of the first three enzymes in some cases remained unchanged. There was no correlation between the enzyme activity and the radiation dose as well as the age of the patients. Conclusion: It is demonstrated that the delayed effects of radiation damage to erythrocyte enzymes are most significant in PK of glycolysis, G6PD of hexose monophosphate shunt and MR of redox reaction. It is suggested that the genes related to the synthesis of erythrocyte enzymes may be damaged by radiation

  17. BisGMA/TEGDMA dental nanocomposites containing glyoxylic acid modified high-aspect ratio hydroxyapatite nanofibers with enhanced dispersion

    Science.gov (United States)

    Chen, Liang; Xu, Changqi; Wang, Yong; Shi, Jian; Yu, Qingsong

    2012-01-01

    The purpose of this research was to investigate the influence of the glyoxylic acid (GA) modification of hydroxyapatite (HAP) nanofibers on their dispersion in bisphenol A glycidyl methacrylate (BisGMA)/triethylene glycol dimethacrylate (TEGDMA) dental composites and also investigate the mechanical properties, water absorption, and water solubility of the resulting dental resins and composites. Scanning/Transmission electron microscopy (STEM) images showed that microsized HAP nanofiber bundles could be effectively broken down to individual HAP nanofibers with an average length of ~15 μm after the surface modification process. Fourier transform infrared spectroscopy (FT-IR), X-ray photoelectron spectroscopy (XPS) and thermal gravimetric analysis (TGA) characterization confirmed glyoxylic acid was chemically grafted on the HAP nanofiber surface, hypothetically by reacting with the amine group on HAP nanofiber surface. The enhanced dispersion of HAP nanofibers in dental matrix led to increased biaxial flexural strength (BFS) compared with the corresponding dental resins and composites filled with untreated HAP nanofibers. In addition, impregnation of small mass fractions of the glyoxylic acid modified HAP nanofibers into the BisGMA/TEGDMA dental resins (5wt%, 10wt%) or composites (2wt%, 3wt%) could also substantially improve the BFS in comparison with the controls(pure resins or dental composites filled with silica particles alone). Larger mass fractions could not further increase the mechanical property or even degrade the BFS values. Water behavior testing results indicated that the addition of glyoxylic acid modified HAP nanofibers resulted in higher water absorption and water solubility values which is not preferred for clinical application. In summary, well dispersed HAP nanofibers and their dental composites with enhanced mechanical property have been successfully fabricated but the water absorption and water solubility of such dental composites need to be

  18. Congenital Intrahepatic Portosystemic Shunts

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Woong Hee; Kim, Young Tong; Jou, Sung Shick; Shin, Hyeong Cheol [Soonchunhyang University, Asan (Korea, Republic of)

    2008-12-15

    Intrahepatic portosystemic shunts are an anomalous connection between the portal vein and hepatic vein/IVC, which may be either congenital or acquired secondary to liver cirrhosis or portal hypertension. Cases of congenital intrahepatic shunts are usually encountered in children and may spontaneously resolve. We report 5 cases of congenital intrahepatic portosystemic shunts in neonates and an adult

  19. Failed Ventriculoperitoneal Shunt: Is Retrograde Ventriculosinus Shunt a Reliable Option?

    Science.gov (United States)

    Oliveira, Matheus Fernandes de; Teixeira, Manoel Jacobsen; Reis, Rodolfo Casimiro; Petitto, Carlo Emanuel; Gomes Pinto, Fernando Campos

    2016-08-01

    Currently, the treatment of hydrocephalus is mainly carried out through a ventriculoperitoneal shunt (VPS) insertion. However, in some cases, there may be surgical revisions and requirement of an alternative distal site for shunting. There are several described distal sites, and secondary options after VPS include ventriculopleural and ventriculoatrial shunt, which have technical difficulties and harmful complications. In this preliminary report we describe our initial experience with retrograde ventriculosinus shunt (RVSS) after failed VPS. In 3 consecutive cases we applied RVSS to treat hydrocephalus in shunt-dependent patients who had previously undergone VPS revision and in which peritoneal space was full of adhesions and fibrosis. RVSS was performed as described by Shafei et al., with some modifications to each case. All 3 patients kept the same clinical profile after RVSS, with no perioperative or postoperative complications. However, revision surgery was performed in the first operative day in 1 out of 3 patients, in which the catheter was not positioned in the superior sagittal sinus. We propose that in cases where VPS is not feasible, RVSS may be a safe and applicable second option. Nevertheless, the long-term follow-up of patients and further learning curve must bring stronger evidence. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Rate of shunt revision as a function of age in patients with shunted hydrocephalus due to myelomeningocele.

    Science.gov (United States)

    Dupepe, Esther B; Hopson, Betsy; Johnston, James M; Rozzelle, Curtis J; Jerry Oakes, W; Blount, Jeffrey P; Rocque, Brandon G

    2016-11-01

    OBJECTIVE It is generally accepted that cerebrospinal fluid shunts fail most frequently in the first years of life. The purpose of this study was to describe the risk of shunt failure for a given patient age in a well-defined cohort with shunted hydrocephalus due to myelomeningocele (MMC). METHODS The authors analyzed data from their institutional spina bifida research database including all patients with MMC and shunted hydrocephalus. For the entire population, the number of shunt revisions in each year of life was determined. Then the number of patients at risk for shunt revision during each year of life was calculated, thus enabling them to calculate the rate of shunt revision per patient in each year of life. In this way, the timing of all shunt revision operations for the entire clinic population and the likelihood of having a shunt revision during each year of life were calculated. RESULTS A total of 655 patients were enrolled in the spina bifida research database, 519 of whom had a diagnosis of MMC and whose mean age was 17.48 ± 11.7 years (median 16 years, range 0-63 years). Four hundred seventeen patients had had a CSF shunt for the treatment of hydrocephalus and thus are included in this analysis. There were 94 shunt revisions in the 1st year of life, which represents a rate of 0.23 revisions per patient in that year. The rate of shunt revision per patient-year initially decreased as age increased, except for an increase in revision frequency in the early teen years. Shunt revisions continued to occur as late as 43 years of age. CONCLUSIONS These data substantiate the idea that shunt revision surgeries in patients with MMC are most common in the 1st year of life and decrease thereafter, except for an increase in the early teen years. A persistent risk of shunt failure was observed well into adult life. These findings underscore the importance of routine follow-up of all MMC patients with shunted hydrocephalus and will aid in counseling patients and

  1. Liver peroxisomal alanine:glyoxylate aminotransferase and the effects of mutations associated with Primary Hyperoxaluria Type I: An overview.

    Science.gov (United States)

    Oppici, Elisa; Montioli, Riccardo; Cellini, Barbara

    2015-09-01

    Liver peroxisomal alanine:glyoxylate aminotransferase (AGT) (EC 2.6.1.44) catalyses the conversion of l-alanine and glyoxylate to pyruvate and glycine, a reaction that allows glyoxylate detoxification. Inherited mutations on the AGXT gene encoding AGT lead to Primary Hyperoxaluria Type I (PH1), a rare disorder characterized by the deposition of calcium oxalate crystals primarily in the urinary tract. Here we describe the results obtained on the biochemical features of AGT as well as on the molecular and cellular effects of polymorphic and pathogenic mutations. A complex scenario on the molecular pathogenesis of PH1 emerges in which the co-inheritance of polymorphic changes and the condition of homozygosis or compound heterozygosis are two important factors that determine the enzymatic phenotype of PH1 patients. All the reported data represent relevant steps toward the understanding of genotype/phenotype correlations, the prediction of the response of the patients to the available therapies, and the development of new therapeutic approaches. This article is part of a Special Issue entitled: Cofactor-dependent proteins: evolution, chemical diversity and bio-applications. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Transjugular intrahepatic portosystemic shunt

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jae Hyung; Han, Joon Koo; Chung, Jin Wook; Han, Man Chung [Seoul National University College of Medicidne, Seoul (Korea, Republic of)

    1992-05-15

    As a new interventional procedure for the control of variceal bleeding, a portosystemic shunt can be established with the installment of metallic stent through the transjugular approach. In order to evaluate the clinical usefulness of the procedure, transjugular intrahepatic portosystemic shunt procedure were performed in 5 patients with variceal bleeding due to liver cirrhosis. The metallic stents were mainly a self expandable Wallstent (Schneider, Switzerland), An 8 to 10 mm shunt was formed by the insertion of the stent and balloon dilatation after puncture of the proximal portal vein from the right or middle hepatic vein. The patency of the shunt was proven by portography after the procedure. The portal pressure measured in 3 patients before and after the procedure improved with decrease from 31 mmHg to 25 mmHg. The procedure failed in 1 patient due to pre-existing portal vein thrombosis. During the follow-up period from 1 month to 4 months, shunts were patent in all 4 patients. However, hepatic encephalopathy occurred in one patient one week following the procedure. Though the follow-up period was not long enough for full evaluation, we found the transjugular intrahepatic portosystemic shunt was a safe and effective procedure for the control of variceal bleeding by lowering the portal pressure. For the appropriate application for this procedure, the optimal size of the shunt and optical degree of the resultant decompression are yet to be determined in the future.

  3. Shunt detection and measurement

    International Nuclear Information System (INIS)

    Grossman, W.

    1986-01-01

    Detection, localization, and quantification of intracardiac shunts are an integral part of the hemodynamic evaluation of patients with congenital heart disease. In most cases, an intracardiac shunt is suspected on the basis of the clinical evaluation of the patient prior to catheterization. However, there are several circumstances in which data obtained at catheterization should alert the cardiologist to look for a shunt that previously had not been suspected

  4. Pathological Predictors of Shunt Stenosis and Hepatic Encephalopathy after Transjugular Intrahepatic Portosystemic Shunt

    Directory of Open Access Journals (Sweden)

    Fuliang He

    2016-01-01

    Full Text Available Background. Transjugular intrahepatic portosystemic shunt (TIPS is an artificial channel from the portal vein to the hepatic vein or vena cava for controlling portal vein hypertension. The major drawbacks of TIPS are shunt stenosis and hepatic encephalopathy (HE; previous studies showed that post-TIPS shunt stenosis and HE might be correlated with the pathological features of the liver tissues. Therefore, we analyzed the pathological predictors for clinical outcome, to determine the risk factors for shunt stenosis and HE after TIPS. Methods. We recruited 361 patients who suffered from portal hypertension symptoms and were treated with TIPS from January 2009 to December 2012. Results. Multivariate logistic regression analysis showed that the risk of shunt stenosis was increased with more severe inflammation in the liver tissue (OR, 2.864; 95% CI: 1.466–5.592; P=0.002, HE comorbidity (OR, 6.266; 95% CI, 3.141–12.501; P<0.001, or higher MELD score (95% CI, 1.298–1.731; P<0.001. Higher risk of HE was associated with shunt stenosis comorbidity (OR, 6.266; 95% CI, 3.141–12.501; P<0.001, higher stage of the liver fibrosis (OR, 2.431; 95% CI, 1.355–4.359; P=0.003, and higher MELD score (95% CI, 1.711–2.406; P<0.001. Conclusion. The pathological features can predict individual susceptibility to shunt stenosis and HE.

  5. Peroxisomal alanine: glyoxylate aminotransferase AGT1 is indispensable for appressorium function of the rice blast pathogen, Magnaporthe oryzae.

    Directory of Open Access Journals (Sweden)

    Vijai Bhadauria

    Full Text Available The role of β-oxidation and the glyoxylate cycle in fungal pathogenesis is well documented. However, an ambiguity still remains over their interaction in peroxisomes to facilitate fungal pathogenicity and virulence. In this report, we characterize a gene encoding an alanine, glyoxylate aminotransferase 1 (AGT1 in Magnaporthe oryzae, the causative agent of rice blast disease, and demonstrate that AGT1 is required for pathogenicity of M. oryzae. Targeted deletion of AGT1 resulted in the failure of penetration via appressoria; therefore, mutants lacking the gene were unable to induce blast symptoms on the hosts rice and barley. This penetration failure may be associated with a disruption in lipid mobilization during conidial germination as turgor generation in the appressorium requires mobilization of lipid reserves from the conidium. Analysis of enhanced green fluorescent protein expression using the transcriptional and translational fusion with the AGT1 promoter and open reading frame, respectively, revealed that AGT1 expressed constitutively in all in vitro grown cell types and during in planta colonization, and localized in peroxisomes. Peroxisomal localization was further confirmed by colocalization with red fluorescent protein fused with the peroxisomal targeting signal 1. Surprisingly, conidia produced by the Δagt1 mutant were unable to form appressoria on artificial inductive surfaces, even after prolonged incubation. When supplemented with nicotinamide adenine dinucleotide (NAD(++pyruvate, appressorium formation was restored on an artificial inductive surface. Taken together, our data indicate that AGT1-dependent pyruvate formation by transferring an amino group of alanine to glyoxylate, an intermediate of the glyoxylate cycle is required for lipid mobilization and utilization. This pyruvate can be converted to non-fermentable carbon sources, which may require reoxidation of NADH generated by the β-oxidation of fatty acids to NAD(+ in

  6. 30 CFR 56.6401 - Shunting.

    Science.gov (United States)

    2010-07-01

    ... HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Explosives Electric Blasting § 56.6401 Shunting. Except during testing— (a) Electric detonators shall be kept shunted until connected to the blasting line or wired into a blasting round; (b) Wired rounds shall be kept shunted until...

  7. A kinetic study of the enhancement of solution chemiluminescence of glyoxylic acid oxidation by manganese species.

    Science.gov (United States)

    Otamonga, Jean-Paul; Abdel-Mageed, Amal; Agater, Irena B; Jewsbury, Roger A

    2015-08-01

    In order to study the mechanism of the enhancement of solution chemiluminescence, the kinetics of the decay of the oxidant and the chemiluminescence emission were followed for oxidations by permanganate, manganese dioxide sol and Mn(3+) (aq) of glyoxylic acid, using stopped-flow spectrophotometry. Results are reported for the glyoxylic acid oxidized under pseudo first-order conditions and in an acidic medium at 25 °C. For permanganate under these conditions, the decay is sigmoidal, consistent with autocatalysis, and for manganese dioxide sol and Mn(3+) it is pseudo first order. The effects of the presence of aqueous formaldehyde and Mn(2+) were observed and a fit to a simple mechanism is discussed. It is concluded that chemiluminescent enhancement in these systems is best explained by reaction kinetics. Copyright © 2014 John Wiley & Sons, Ltd.

  8. Portal hypertension: A critical appraisal of shunt procedures with emphasis on distal splenorenal shunt in children

    Directory of Open Access Journals (Sweden)

    Nitin Sharma

    2014-01-01

    Full Text Available Background: Extrahepatic portal venous obstruction (EHPVO is the most common cause of pediatric portal hypertension. We analyzed the investigative protocol and results of portosystemic shunts in this group of patients. Materials and Methods: A total of 40 consecutive children aged below 12 years operated with a diagnosis of extra-hepatic portal hypertension formed the study group. Historical data and clinical data were collected. All patients underwent upper gastrointestinal endoscopy, ultrasound Doppler and computed tomographic portogram pre-operatively and post-operatively. Results with respect to shunt patency, hypersplenism and efficacy of different radiological investigations were collected. Results: A total of 40 patients, 28 boys and 12 girls constituted the study group. Lienorenal shunt (LRS was performed in 14 patients; distal splenorenal shunt in 21 patients and side-to-side lienorenal shunt in 4 patients, inferior mesenteric renal shunt was performed in 1 patient. Follow-up ranged from 36 to 70 months. At a minimum follow-up of 3 years, 32 (80% patients were found to have patent shunts. Patent shunts could be visualized in 30/32 patients with computer tomographic portogram (CTP and 28/32 with ultrasound. Varices regressed completely in 26/32 patients and in the rest incomplete regression was seen. Spleen completely regressed in 19/25 patients. Hypersplenism resolved in all patients with patent shunts. Conclusions: Portosystemic shunting in children with EHPVO is a viable option. While long-term cure rates are comparable with sclerotherapy, repeated hospital visits are reduced with one time surgery. Pre-operative and post-operative assessment can be performed with complimentary use of ultrasound, CTP and endoscopy.

  9. Topological analysis of carbon flux during multi-stress adaptation in Halomonas sp. AAD12

    Directory of Open Access Journals (Sweden)

    Hilal Mangaoglu Yoruk

    2015-11-01

    Conclusions: The operation of the glyoxylate shunt as the major anaplerotic pathway and the degradation of 6-phosphogluconate through the Entner–Doudoroff Pathway were the major factors in causing a distinction between the observed phenotypes.

  10. Over-drainage and persistent shunt-dependency in patients with idiopathic intracranial hypertension treated with shunts and bariatric surgery.

    Science.gov (United States)

    Roth, Jonathan; Constantini, Shlomi; Kesler, Anat

    2015-01-01

    Idiopathic intracranial hypertension (IIH) may lead to visual impairment. Shunt surgery is indicated for refractory IIH-related symptoms that persist despite medical treatment, or those presenting with significant visual decline. Obesity is a risk factor for IIH; a reduction in weight has been shown to improve papilledema. Bariatric surgery (BS) has been suggested for treating IIH associated with morbid obesity. In this study, we describe a high rate of over-drainage (OD) seen in patients following shunts and BS. The study cohort includes 13 patients with IIH that underwent shunt surgery for treatment of the IIH-related symptoms. Six patients underwent BS in addition to the shunt surgery (but not concomitantly). Seven patients had only shunt surgeries with no BS. Data were collected retrospectively. BS effectively led to weight reduction (body mass index decreasing from 43 ± 4 to 28 ± 5). Patients undergoing BS had 1-6 (2.5 ± 1.9) shunt revisions for OD following BS, as opposed to 0-3 (1.4 ± 1.1) revisions prior to BS over similar time spans (statistically insignificant difference), and 0-6 (1.6 ± 2.5) revisions among the non-BS patients over a longer time span (statistically insignificant difference). Two patients in the BS group underwent shunt externalization and closure; however, they proved to be shunt-dependent. Patients with IIH that undergo shunt surgery and BS (not concomitantly) may suffer from OD symptoms, necessitating multiple shunt revisions, and valve upgrades. Despite BS being a valid primary treatment for some patients with IIH, among shunted patients, BS may not lead to resolution of IIH-related symptoms and patients may remain shunt-dependent.

  11. GABA transaminases from Saccharomyces cerevisiae and Arabidopsis thaliana complement function in cytosol and mitochondria.

    Science.gov (United States)

    Cao, Juxiang; Barbosa, Jose M; Singh, Narendra; Locy, Robert D

    2013-07-01

    GABA transaminase (GABA-T) catalyses the conversion of GABA to succinate semialdehyde (SSA) in the GABA shunt pathway. The GABA-T from Saccharomyces cerevisiae (ScGABA-TKG) is an α-ketoglutarate-dependent enzyme encoded by the UGA1 gene, while higher plant GABA-T is a pyruvate/glyoxylate-dependent enzyme encoded by POP2 in Arabidopsis thaliana (AtGABA-T). The GABA-T from A. thaliana is localized in mitochondria and mediated by an 18-amino acid N-terminal mitochondrial targeting peptide predicated by both web-based utilities TargetP 1.1 and PSORT. Yeast UGA1 appears to lack a mitochondrial targeting peptide and is localized in the cytosol. To verify this bioinformatic analysis and examine the significance of ScGABA-TKG and AtGABA-T compartmentation and substrate specificity on physiological function, expression vectors were constructed to modify both ScGABA-TKG and AtGABA-T, so that they express in yeast mitochondria and cytosol. Physiological function was evaluated by complementing yeast ScGABA-TKG deletion mutant Δuga1 with AtGABA-T or ScGABA-TKG targeted to the cytosol or mitochondria for the phenotypes of GABA growth defect, thermosensitivity and heat-induced production of reactive oxygen species (ROS). This study demonstrates that AtGABA-T is functionally interchangeable with ScGABA-TKG for GABA growth, thermotolerance and limiting production of ROS, regardless of location in mitochondria or cytosol of yeast cells, but AtGABA-T is about half as efficient in doing so as ScGABA-TKG. These results are consistent with the hypothesis that pyruvate/glyoxylate-limited production of NADPH mediates the effect of the GABA shunt in moderating heat stress in Saccharomyces. Copyright © 2013 John Wiley & Sons, Ltd.

  12. Global changes in the proteome of Cupriavidus necator H16 during poly-(3-hydroxybutyrate) synthesis from various biodiesel by-product substrates.

    Science.gov (United States)

    Sharma, Parveen K; Fu, Jilagamazhi; Spicer, Victor; Krokhin, Oleg V; Cicek, Nazim; Sparling, Richard; Levin, David B

    2016-12-01

    Synthesis of poly-[3-hydroxybutyrate] (PHB) by Cupriavidus necator H16 in batch cultures was evaluated using three biodiesel-derived by-products as the sole carbon sources: waste glycerol (REG-80, refined to 80 % purity with negligible free fatty acids); glycerol bottom (REG-GB, with up to 65 % glycerol and 35 % free fatty acids), and free fatty acids (REG-FFA, with up to 75 % FFA and no glycerol). All the three substrates supported growth and PHB production by C. necator, with polymer accumulation ranging from 9 to 84 % cell dry weight (cdw), depending on the carbon source. To help understand these differences, proteomic analysis indicated that although C. necator H16 was able to accumulate PHB during growth on all three biodiesel by-products, no changes in the levels of PHB synthesis enzymes were observed. However, significant changes in the levels of expression were observed for two Phasin proteins involved with PHB accumulation, and for a number of gene products in the fatty acid β-oxidation pathway, the Glyoxylate Shunt, and the hydrogen (H2) synthesis pathways in C. necator cells cultured with different substrates. The glycerol transport protein (GlpF) was induced in REG-GB and REG-80 glycerol cultures only. Cupriavidus necator cells cultured with REG-GB and REG-FFA showed up-regulation of β-oxidation and Glyoxylate Shunt pathways proteins at 24 h pi, but H2 synthesis pathways enzymes were significantly down-regulated, compared with cells cultured with waste glycerol. Our data confirmed earlier observations of constitutive expression of PHB synthesis proteins, but further suggested that C. necator H16 cells growing on biodiesel-derived glycerol were under oxidative stress.

  13. Flux shunts for undulators

    International Nuclear Information System (INIS)

    Hoyer, E.; Chin, J.; Hassenzahl, W.V.

    1993-05-01

    Undulators for high-performance applications in synchrotron-radiation sources and periodic magnetic structures for free-electron lasers have stringent requirements on the curvature of the electron's average trajectory. Undulators using the permanent magnet hybrid configuration often have fields in their central region that produce a curved trajectory caused by local, ambient magnetic fields such as those of the earth. The 4.6 m long Advanced Light Source (ALS) undulators use flux shunts to reduce this effect. These flux shunts are magnetic linkages of very high permeability material connecting the two steel beams that support the magnetic structures. The shunts reduce the scalar potential difference between the supporting beams and carry substantial flux that would normally appear in the undulator gap. Magnetic design, mechanical configuration of the flux shunts and magnetic measurements of their effect on the ALS undulators are described

  14. Arterioportal shunts on dynamic computed tomography

    International Nuclear Information System (INIS)

    Nakayama, T.; Hiyama, Y.; Ohnishi, K.; Tsuchiya, S.; Kohno, K.; Nakajima, Y.; Okuda, K.

    1983-01-01

    Thirty-two patients, 20 with hepatocelluar carcinoma and 12 with liver cirrhosis, were examined by dynamic computed tomography (CT) using intravenous bolus injection of contrast medium and by celiac angiography. Dynamic CT disclosed arterioportal shunting in four cases of hepatocellular carcinoma and in one of cirrhosis. In three of the former, the arterioportal shunt was adjacent to a mass lesion on CT, suggesting tumor invasion into the portal branch. In one with hepatocellular carcinoma, the shunt was remote from the mass. In the case with cirrhosis, there was no mass. In these last two cases, the shunt might have been caused by prior percutaneous needle puncture. In another case of hepatocellular carcinoma, celiac angiography but not CT demonstrated an arterioportal shunt. Thus, dynamic CT was diagnostic in five of six cases of arteriographically demonstrated arterioportal shunts

  15. Research progress in TIPS shunt dysfunction and recanalization

    Directory of Open Access Journals (Sweden)

    WANG Tingting

    2015-11-01

    Full Text Available Transjugular intrahepatic portosystemic shunt (TIPS is widely used in the treatment of cirrhotic portal hypertension and its associated complications. However, postoperative shunt dysfunction has been an important factor restricting the clinical application of TIPS. This article summarizes the use of shunt, the incidence of shunt dysfunction after TIPS, preventive measures and diagnostic methods for shunt dysfunction, and indications and techniques of shunt recanalization, in order to enhance our knowledge of shunt dysfunction and recanalization, which could further improve the efficacy of TIPS for cirrhotic portal hypertension.

  16. Aqueous shunt implantation in glaucoma

    Directory of Open Access Journals (Sweden)

    Jing Wang

    2017-01-01

    Full Text Available Aqueous shunts or glaucoma drainage devices are increasingly utilized in the management of refractory glaucoma. The general design of the most commonly-used shunts is based on the principles of the Molteno implant: ie. a permanent sclerostomy (tube, a predetermined bleb area (plate and diversion of aqueous humour to the equatorial region and away from the limbal subconjunctival space. These three factors make aqueous shunts more resistant to scarring as compared to trabeculectomy. The two most commonly used shunts are the Ahmed Glaucoma Valve, which contains a flow-restrictor, and the non-valved Baervedlt Glaucoma Implant. While the valved implants have a lower tendency to hypotony and related complications, the non-valved implants with larger, more-biocompatible end plate design, achieve lower intraocular pressures with less encapsulation. Non-valved implants require additional suturing techniques to prevent early hypotony and a number of these methods will be described. Although serious shunt-related infection is rare, corneal decompensation and diplopia are small but significant risks.

  17. Subgaleo-peritoneal shunt: An effective and safer alternative to lumboperitoneal shunt in the management of persistent or recurrent iatrogenic cranial pseudomeningoceles.

    Science.gov (United States)

    Kiran, Narayanam Anantha Sai; Thakar, Sumit; Mohan, Dilip; Aryan, Saritha; Rao, Arun Sadashiva; Hegde, Alangar S

    2013-01-01

    Subgaleo-peritoneal (SP) shunting for pseudomeningoceles (PMCs) is an effective and safer alternative as compared to the lumboperitoneal (LP) shunt. SP shunting was done in six patients (14-60 years) with persistent or recurrent PMCs using the cranial (ventricular part) and the distal parts of a Chhabra shunt connected by a rigid connector without any intervening chamber or valve. Two patients had undergone a prior LP shunt that had failed. One patient was unsuitable for a LP shunt placement. The PMC subsided completely in all the patients following the SP shunt. In one patient, the shunt got displaced and required repositioning. None of the patients developed symptoms of over-drainage or any other complication. All patients were asymptomatic at a mean follow-up of 15 months. These results suggest that SP shunting is a safe, simple, and effective alternative to the traditional LP shunt in the management of persistent or recurrent cranial PMCs.

  18. Quadrupole shunt experiments at SPEAR

    International Nuclear Information System (INIS)

    Corbett, W.J.; Hettel, R.O.; Nuhn, H.-D.

    1996-05-01

    As part of a program to align and stabilize the SPEAR storage ring, a switchable shunt resistor was installed on each quadrupole to bypass a small percentage of the magnet current. The impact of a quadrupole shunt is to move the electron beam orbit in proportion to the off-axis beam position at the quadrupole, and to shift the betatron tune. Initially, quadrupole shunts in SPEAR were used to position the electron beam in the center of the quadrupoles. This provided readback offsets for nearby beam position monitors, and helped to steer the photon beams with low-amplitude corrector currents. The shunt-induced tune shift measurements were then processed in MAD to derive a lattice model

  19. Pediatric ventriculoperitoneal shunts and their complications: An analysis

    Directory of Open Access Journals (Sweden)

    Nitin Agarwal

    2017-01-01

    Conclusion: With this retrospective review of complications of VP shunts, age at initial shunt insertion and the interval between the age of initial shunt placement and onset of complications were the most important patient-related predictors of shunt failure. The different predominant etiological factors responsible for early and late shunt failure were infective and mechanical complications, respectively.

  20. Superconducting fault current-limiter with variable shunt impedance

    Science.gov (United States)

    Llambes, Juan Carlos H; Xiong, Xuming

    2013-11-19

    A superconducting fault current-limiter is provided, including a superconducting element configured to resistively or inductively limit a fault current, and one or more variable-impedance shunts electrically coupled in parallel with the superconducting element. The variable-impedance shunt(s) is configured to present a first impedance during a superconducting state of the superconducting element and a second impedance during a normal resistive state of the superconducting element. The superconducting element transitions from the superconducting state to the normal resistive state responsive to the fault current, and responsive thereto, the variable-impedance shunt(s) transitions from the first to the second impedance. The second impedance of the variable-impedance shunt(s) is a lower impedance than the first impedance, which facilitates current flow through the variable-impedance shunt(s) during a recovery transition of the superconducting element from the normal resistive state to the superconducting state, and thus, facilitates recovery of the superconducting element under load.

  1. In vitro adsorption of oxalic acid and glyoxylic acid onto activated charcoal, resins and hydrous zirconium oxide

    NARCIS (Netherlands)

    Scholtens, R.; Scholten, J.; de Koning, H. W.; Tijssen, J.; ten Hoopen, H. W.; Olthuis, F. M.; Feijen, J.

    1982-01-01

    Patients suffering from primary hyperoxaluria show elevated plasma concentrations of oxalic acid and glyoxylic acid. The in vitro adsorption of these compounds into activated charcoal, a series of neutral and ion exchange resins and onto hydrous zirconium oxide has been investigated. Hydrous

  2. Idiopathic intracranial hypertension: lumboperitoneal shunts versus ventriculoperitoneal shunts--case series and literature review.

    LENUS (Irish Health Repository)

    Abubaker, Khalid

    2011-02-01

    Idiopathic intracranial hypertension (IIH) is an uncommon but important cause of headache that can lead to visual loss. This study was undertaken to review our experience in the treatment of IIH by neuronavigation-assisted ventriculoperitoneal (VP) shunts with programmable valves as compared to lumboperitoneal (LP) shunts.

  3. Quadrupole shunt experiments at SPEAR

    International Nuclear Information System (INIS)

    Corbett, W.J.; Hettel, R.O.; Nuhn, H.

    1997-01-01

    As part of a program to align and stabilize the SPEAR storage ring, a switchable shunt resistor was installed on each quadrupole to bypass a small percentage of the magnet current. The impact of a quadrupole shunt is to move the electron beam orbit in proportion to the off-axis beam position at the quadrupole and to shift the betatron tune. Initially, quadrupole shunts in SPEAR were used to position the electron beam in the center of the quadrupoles. This provided readback offsets for nearby beam position monitors and helped to steer the photon beams with low-amplitude corrector currents. The shunt-induced tune shift measurements were then processed in MAD to derive a lattice model. copyright 1997 American Institute of Physics

  4. A wireless monitoring system for Hydrocephalus shunts.

    Science.gov (United States)

    Narayanaswamy, A; Nourani, M; Tamil, L; Bianco, S

    2015-08-01

    Patients with Hydrocephalus are usually treated by diverting the excess Cerebrospinal Fluid (CSF) to other parts of the body using shunts. More than 40 percentage of shunts implanted fail within the first two years. Obstruction in the shunts is one of the major causes of failure (45 percent) and the detection of obstruction reduces the complexity of the revision surgery. This paper describes a proposed wireless monitoring system for clog detection and flow measurement in shunts. A prototype was built using multiple pressure sensors along the shunt catheters for sensing the location of clog and flow rate. Regular monitoring of flow rates can be used to adjust the valve in the shunt to prevent over drainage or under drainage of CSF. The accuracy of the flow measurement is more than 90 percent.

  5. Hydrocephalus shunt technology: 20 years of experience from the Cambridge Shunt Evaluation Laboratory.

    Science.gov (United States)

    Chari, Aswin; Czosnyka, Marek; Richards, Hugh K; Pickard, John D; Czosnyka, Zofia H

    2014-03-01

    The Cambridge Shunt Evaluation Laboratory was established 20 years ago. This paper summarizes the findings of that laboratory for the clinician. Twenty-six models of valves have been tested long-term in the shunt laboratory according to the expanded International Organization for Standardization 7197 standard protocol. The majority of the valves had a nonphysiologically low hydrodynamic resistance (from 1.5 to 3 mm Hg/[ml/min]), which may result in overdrainage related to posture and during nocturnal cerebral vasogenic waves. A long distal catheter increases the resistance of these valves by 100%-200%. Drainage through valves without a siphon-preventing mechanism is very sensitive to body posture, which may result in grossly negative intracranial pressure. Siphon-preventing accessories offer a reasonable resistance to negative outlet pressure; however, accessories with membrane devices may be blocked by raised subcutaneous pressure. In adjustable valves, the settings may be changed by external magnetic fields of intensity above 40 mT (exceptions: ProGAV, Polaris, and Certas). Most of the magnetically adjustable valves produce large distortions on MRI studies. The behavior of a valve revealed during testing is of relevance to the surgeon and may not be adequately described in the manufacturer's product information. The results of shunt testing are helpful in many circumstances, such as the initial choice of shunt and the evaluation of the shunt when its dysfunction is suspected.

  6. Congenital portosystemic shunts with and without gastrointestinal bleeding - case series

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Ying; Chen, Jun; Chen, Qi; Ji, Min; Pa, Mier; Qiao, Zhongwei [Children' s Hospital of Fudan University, Department of Radiology, Shanghai (China); Zhu, Hui [Fudan University Shanghai Cancer Center, Department of Radiology, Shanghai (China); Zheng, Shan [Children' s Hospital of Fudan University, Department of Surgery, Shanghai (China)

    2015-12-15

    The clinical presentation of congenital portosystemic shunt is variable and gastrointestinal bleeding is an uncommon presentation. To describe the imaging features of congenital portosystemic shunt as it presented in 11 children with (n = 6) and without gastrointestinal bleeding (n = 5). We performed a retrospective study on a clinical and imaging dataset of 11 children diagnosed with congenital portosystemic shunt. A total of 11 children with congenital portosystemic shunt were included in this study, 7 with extrahepatic portosystemic shunts and 4 with intrahepatic portosystemic shunts. Six patients with gastrointestinal bleeding had an extrahepatic portosystemic shunt, and the imaging results showed that the shunts originated from the splenomesenteric junction (n = 5) or splenic vein (n = 1) and connected to the internal iliac vein. Among the five cases of congenital portosystemic shunt without gastrointestinal bleeding, one case was an extrahepatic portosystemic shunt and the other four were intrahepatic portosystemic shunts. Most congenital portosystemic shunt patients with gastrointestinal bleeding had a shunt that drained portal blood into the iliac vein via an inferior mesenteric vein. This type of shunt was uncommon, but the concomitant rate of gastrointestinal bleeding with this type of shunt was high. (orig.)

  7. Outcomes of systemic to pulmonary artery shunts in patients weighing less than 3 kg: analysis of shunt type, size, and surgical approach.

    Science.gov (United States)

    Myers, John W; Ghanayem, Nancy S; Cao, Yumei; Simpson, Pippa; Trapp, Katie; Mitchell, Michael E; Tweddell, James S; Woods, Ronald K

    2014-02-01

    To evaluate outcomes of systemic to pulmonary artery shunts (SPS) in patients weighing less than 3 kg with regard to shunt type, shunt size, and surgical approach. Patients weighing less than 3 kg who underwent modified Blalock-Taussig or central shunts with polytetrafluoroethylene grafts at our institution from January 1, 2000, to May 31, 2011, were reviewed. Patients who had undergone other major concomitant procedures were excluded from the analysis. Primary outcomes included mortality (discharge mortality and mortality before next planned palliative procedure or definitive repair), cardiac arrest and/or extracorporeal membrane oxygenation (ECMO), and shunt reintervention. In this cohort of 80 patients, discharge survival was 96% (77/80). Postoperative cardiac arrest or ECMO occurred in 6/80 (7.5%), and shunt reintervention was required in 14/80 (17%). On univariate analysis, shunt reintervention was more common in patients with 3-mm shunts (11/30, 37%) compared with 3.5-mm (2/36, 6%) or 4-mm shunts (1/14, 7%) (P approach and cardiac arrest/ECMO or mortality. Multiple logistic regression demonstrated that a shunt size of 3 mm (P = .019) and extracardiac anomaly (P = .047) were associated with shunt reintervention, whereas no variable was associated with cardiac arrest/ECMO or mortality. In this high-risk group of neonates weighing less than 3 kg at the time of SPS, survival to discharge and the next planned surgical procedure was high. Outcomes were good with the 3.5- and 4-mm shunts; however, shunt reintervention was common with 3-mm shunts. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  8. Ventriculosubgaleal shunts for posthemorrhagic hydrocephalus in premature infants.

    Science.gov (United States)

    Willis, Brian K; Kumar, Cherukuri Ravi; Wylen, Esther L; Nanda, Anil

    2005-01-01

    The early management of posthemorrhagic hydrocephalus in premature infants is challenging and controversial. These infants need a temporary cerebrospinal fluid (CSF) diversion procedure until they gain adequate weight, and the blood and protein levels in CSF are reasonably low before permanent shunt can be placed. Various options are available with their associated advantages and disadvantages. Ventriculosubgaleal shunts have been recommended as a more physiologic and less invasive means of achieving this goal. We have performed this procedure in 6 premature infants to evaluate their effectiveness and complications. Six consecutive premature infants with posthemorrhagic hydrocephalus underwent placement of ventriculosubgaleal shunts over a 1-year period of time. We reviewed their clinical and imaging progress to assess the ability of the shunt to control hydrocephalus and the complication rates. In all 6 patients, the ventriculosubgaleal shunt controlled the progression of hydrocephalus as assessed by clinical and imaging parameters. A permanent shunt was avoided in 1 patient (16.6%). However, 4 patients developed shunt infections, 1 involving the ventriculosubgaleal shunt itself, and 3 immediately after conversion to ventriculoperitoneal shunt. The total infection rate of the series was 66.6%. All infections were caused by staphylococcus species. There was only a 1% shunt infection rate in our institution for all nonventriculosubgaleal shunts during the same period of time. Placement of ventriculosubgaleal shunts for interim CSF diversion in neonates with posthemorrhagic hydrocephalus is effective as a temporary method of CSF diversion. However, our experience has shown that it is associated with a unacceptably high CSF infection rate. A potential cause for infection is CSF stasis just beneath the extremely thin skin of the premature infants, promoting colonization by skin flora. CSF sampling before conversion to a permanent shunt and replacement of the proximal

  9. Cell shunt resistance and photovoltaic module performance

    Energy Technology Data Exchange (ETDEWEB)

    McMahon, T.J.; Basso, T.S.; Rummel, S.R. [National Renewable Energy Lab., Golden, CO (United States)

    1996-05-01

    Shunt resistance of cells in photovoltaic modules can affect module power output and could indicate flawed manufacturing processes and reliability problems. The authors describe a two-terminal diagnostic method to directly measure the shunt resistance of individual cells in a series-connected module non-intrusively, without deencapsulation. Peak power efficiency vs. light intensity was measured on a 12-cell, series-connected, single crystalline module having relatively high cell shunt resistances. The module was remeasured with 0.5-, 1-, and 2-ohm resistors attached across each cell to simulate shunt resistances of several emerging technologies. Peak power efficiencies decreased dramatically at lower light levels. Using the PSpice circuit simulator, the authors verified that cell shunt and series resistances can indeed be responsible for the observed peak power efficiency vs. intensity behavior. The authors discuss the effect of basic cell diode parameters, i.e., shunt resistance, series resistance, and recombination losses, on PV module performance as a function of light intensity.

  10. 30 CFR 57.6401 - Shunting.

    Science.gov (United States)

    2010-07-01

    ... HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Explosives Electric Blasting-Surface and Underground § 57.6401 Shunting. Except during testing— (a) Electric detonators shall be kept shunted until connected to the blasting line or wired into a blasting round; (b) Wired rounds shall be...

  11. MR imaging of syringoperitoneal and syringosubarachnoid shunts

    International Nuclear Information System (INIS)

    Hasso, A.N.; Kucharczyk, W.; Mall, J.C.; Colombo, N.; Newton, T.H.; Norman, D.

    1986-01-01

    The authors utilized MR imaging for the evaluation of syringohydromelic shunt procedures in 16 patients. Four characteristic MR imaging findings were seen: ''tethering'' of the spinal cord posteriorly at the site of laminectomy and placement of the shunt tube distortion of the usual elliptical shape of the spinal cord at the site of the shunt, a ''snake-eyes'' appearance of the cord on transverse images which corresponded to the position of the shunt within or next to a collapsed syringohydromelic cavity, and a generous amount of subachnoid space surrounding the collapsed portion of the cavity. Occasionally the shunt could not be visualized on sagittal images but could be seen on transverse images. In the majority of cases, the MR imaging findings were sufficiently characteristic to warrant accurate diagnosis

  12. Enzymatic mechanism of oxalate production in the TCA and glyoxylate pathways using various isolates of Antrodia radiculosa

    Science.gov (United States)

    K.M. Jenkins; S.V. Diehl; C.A. Clausen; F. Green

    2011-01-01

    Brown-rot fungi produce oxalate in large amounts; however, levels of accumulation and function vary by species. Copper-tolerant fungi, like Antrodia radiculosa, produce and accumulate high levels of oxalate in response to copper. Oxalate biosynthesis in copper-tolerant fungi has been linked to the glyoxylate and tricarboxylic acid (TCA) cycles. Within these two cycles...

  13. Transjugular Intrahepatic Portosystemic Shunt Dysfunction: Concordance of Clinical Findings, Doppler Ultrasound Examination, and Shunt Venography.

    Science.gov (United States)

    Owen, Joshua M; Gaba, Ron Charles

    2016-01-01

    The objective of this study was to evaluate the concordance between clinical symptoms, Doppler ultrasound (US), and shunt venography for the detection of stent-graft transjugular intrahepatic portosystemic shunt (TIPS) dysfunction. Forty-one patients (M:F 30:11, median age 55 years) who underwent contemporaneous clinical exam, Doppler US, and TIPS venography between 2003 and 2014 were retrospectively studied. Clinical symptoms (recurrent ascites or variceal bleeding) were dichotomously classified as present/absent, and US and TIPS venograms were categorized in a binary fashion as normal/abnormal. US abnormalities included high/low (>190 or 50 cm/s), absent flow, and return of antegrade intra-hepatic portal flow. Venographic abnormalities included shunt stenosis/occlusion and/or pressure gradient elevation. Clinical and imaging concordance rates were calculated. Fifty-two corresponding US examinations and venograms were assessed. The median time between studies was 3 days. Forty of 52 (77%) patients were symptomatic, 33/52 (64%) US examinations were abnormal, and 20/52 (38%) TIPS venograms were abnormal. Concordance between clinical symptoms and TIPS venography was 48% (25/52), while the agreement between US and shunt venography was 65% (34/52). Clinical symptoms and the US concurred in 60% (31/52) of the patients. The sensitivity of clinical symptoms and US for the detection of venographically abnormal shunts was 80% (16/20) and 85% (17/20), respectively. Both clinical symptoms and the US had low specificity (25%, 8/32 and 50%, 16/32) for venographically abnormal shunts. Clinical findings and the US had low concordance rates with TIPS venography, with acceptable sensitivity but poor specificity. These findings suggest the need for improved noninvasive imaging methods for stent-graft TIPS surveillance.

  14. Ventriculoperitoneal shunt infections in children

    African Journals Online (AJOL)

    1991-02-02

    Feb 2, 1991 ... shunts: epidemiology, clinical manifestations and therapy.] Infecr Vis 1975;. 13: 543-552. 4. Odio C, McCracken GH jun, Nelson JD. CSF shunt infections in pediatrics, a seven-year experience. Am] Dis Child 1984; 138: 1103-1108. 5. Meirovitch J, Kitai-Cohen Y, Keren G, Fiendler G, Rubinstein E. Cerebro-.

  15. An experimental in-vivo canine model for adult shunt infection

    Directory of Open Access Journals (Sweden)

    Procop Gary

    2008-10-01

    Full Text Available Abstract Background Detailed human studies of the mechanisms and development of shunt infection in real time are not possible, and we have developed a canine hydrocephalus model to overcome this. The intention of this pilot study was to show that the canine hydrocephalus model could be shunted using conventional "human" shunts, and that a shunt infection could be established so that further studies could then be planned. Methods Hydrocephalus was induced in seven dogs (Canis familiaris by fourth ventricle obstruction. Four weeks later they were shunted using a Hakim Precision valve. Four of the dogs received shunts whose ventricular catheter had been inoculated with Staphylococcus epidermidis, and three were uninoculated controls. Four weeks after shunting the dogs were sacrificed and necropsy was performed. Removed shunts and tissue samples were examined microbiologically and isolates were subjected to detailed identification and genomic comparison. Results All the dogs remained well after shunting. Examination of removed shunt components revealed S. epidermidis in the brain and throughout the shunt system in the four inoculated animals, but in two of these Staphylococcus intermedius was also found. S. intermedius was also isolated from all three "negative" controls. There were slight differences between S. intermedius strains suggesting endogenous infection rather than cross- infection from a point source. Conclusion Shunt infection was established in the canine model, and had the experiment been extended beyond four weeks the typical microbiological, pathological and clinical features might have appeared. The occurrence of unplanned shunt infections in control animals due to canine normal skin flora reflects human clinical experience and underlines the usual source of bacteria causing shunt infection.

  16. Internal carotid artery rupture caused by carotid shunt insertion.

    Science.gov (United States)

    Illuminati, Giulio; Caliò, Francesco G; Pizzardi, Giulia; Vietri, Francesco

    2015-01-01

    Shunting is a well-accepted method of maintaining cerebral perfusion during carotid endarterectomy (CEA). Nonetheless, shunt insertion may lead to complications including arterial dissection, embolization, and thrombosis. We present a complication of shunt insertion consisting of arterial wall rupture, not reported previously. A 78-year-old woman underwent CEA combined with coronary artery bypass grafting (CABG). At the time of shunt insertion an arterial rupture at the distal tip of the shunt was detected and was repaired via a small saphenous vein patch. Eversion CEA and subsequent CABG completed the procedure whose postoperative course was uneventful. Shunting during combined CEA-CABG may be advisable to assure cerebral protection from possible hypoperfusion due to potential hemodynamic instability of patients with severe coronary artery disease. Awareness and prompt management of possible shunt-related complications, including the newly reported one, may contribute to limiting their harmful effect. Arterial wall rupture is a possible, previously not reported, shunt-related complication to be aware of when performing CEA. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. Cranial dural arteriovenous shunts. Part 4. Clinical presentation of the shunts with leptomeningeal venous drainage.

    Science.gov (United States)

    Baltsavias, Gerasimos; Spiessberger, Alex; Hothorn, Torsten; Valavanis, Anton

    2015-04-01

    Cranial dural arteriovenous fistulae have been classified into high- and low-risk lesions mainly based on the pattern of venous drainage. Those with leptomeningeal venous drainage carry a higher risk of an aggressive clinical presentation. Recently, it has been proposed that the clinical presentation should be considered as an additional independent factor determining the clinical course of these lesions. However, dural shunts with leptomeningeal venous drainage include a very wide spectrum of inhomogeneous lesions. In the current study, we correlated the clinical presentation of 107 consecutive patients harboring cranial dural arteriovenous shunts with leptomeningeal venous drainage, with their distinct anatomic and angiographic features categorized into eight groups based on the "DES" (Directness and Exclusivity of leptomeningeal venous drainage and features of venous Strain) concept. We found that among these groups, there are significant angioarchitectural differences, which are reflected by considerable differences in clinical presentation. Leptomeningeal venous drainage of dural sinus shunts that is neither direct nor exclusive and without venous strain manifested only benign symptoms (aggressive presentation 0%). On the other end of the spectrum, the bridging vein shunts with direct and exclusive leptomeningeal venous drainage and venous strain are expected to present aggressive symptoms almost always and most likely with bleeding (aggressive presentation 91.5%). Important aspects of the above correlations are discussed. Therefore, the consideration of leptomeningeal venous drainage alone, for prediction of the clinical presentation of these shunts appears insufficient. Angiographic analysis based on the above concept, offers the possibility to distinguish the higher- from the lower-risk types of leptomeningeal venous drainage. In this context, consideration of the clinical presentation as an additional independent factor for the prediction of their clinical

  18. Transjugular Intrahepatic Portosystemic Shunt Dysfunction: Concordance of Clinical Findings, Doppler Ultrasound Examination, and Shunt Venography

    Directory of Open Access Journals (Sweden)

    Joshua M Owen

    2016-01-01

    Full Text Available Objectives: The objective of this study was to evaluate the concordance between clinical symptoms, Doppler ultrasound (US, and shunt venography for the detection of stent-graft transjugular intrahepatic portosystemic shunt (TIPS dysfunction. Materials and Methods: Forty-one patients (M:F 30:11, median age 55 years who underwent contemporaneous clinical exam, Doppler US, and TIPS venography between 2003 and 2014 were retrospectively studied. Clinical symptoms (recurrent ascites or variceal bleeding were dichotomously classified as present/absent, and US and TIPS venograms were categorized in a binary fashion as normal/abnormal. US abnormalities included high/low (>190 or 50 cm/s, absent flow, and return of antegrade intra-hepatic portal flow. Venographic abnormalities included shunt stenosis/occlusion and/or pressure gradient elevation. Clinical and imaging concordance rates were calculated. Results: Fifty-two corresponding US examinations and venograms were assessed. The median time between studies was 3 days. Forty of 52 (77% patients were symptomatic, 33/52 (64% US examinations were abnormal, and 20/52 (38% TIPS venograms were abnormal. Concordance between clinical symptoms and TIPS venography was 48% (25/52, while the agreement between US and shunt venography was 65% (34/52. Clinical symptoms and the US concurred in 60% (31/52 of the patients. The sensitivity of clinical symptoms and US for the detection of venographically abnormal shunts was 80% (16/20 and 85% (17/20, respectively. Both clinical symptoms and the US had low specificity (25%, 8/32 and 50%, 16/32 for venographically abnormal shunts. Conclusion: Clinical findings and the US had low concordance rates with TIPS venography, with acceptable sensitivity but poor specificity. These findings suggest the need for improved noninvasive imaging methods for stent-graft TIPS surveillance.

  19. Impedance Changes Indicate Proximal Ventriculoperitoneal Shunt Obstruction In Vitro.

    Science.gov (United States)

    Basati, Sukhraaj; Tangen, Kevin; Hsu, Ying; Lin, Hanna; Frim, David; Linninger, Andreas

    2015-12-01

    Extracranial cerebrospinal fluid (CSF) shunt obstruction is one of the most important problems in hydrocephalus patient management. Despite ongoing research into better shunt design, robust and reliable detection of shunt malfunction remains elusive. The authors present a novel method of correlating degree of tissue ingrowth into ventricular CSF drainage catheters with internal electrical impedance. The impedance based sensor is able to continuously monitor shunt patency using intraluminal electrodes. Prototype obstruction sensors were fabricated for in-vitro analysis of cellular ingrowth into a shunt under static and dynamic flow conditions. Primary astrocyte cell lines and C6 glioma cells were allowed to proliferate up to 7 days within a shunt catheter and the impedance waveform was observed. During cell ingrowth a significant change in the peak-to-peak voltage signal as well as the root-mean-square voltage level was observed, allowing the impedance sensor to potentially anticipate shunt malfunction long before it affects fluid drainage. Finite element modeling was employed to demonstrate that the electrical signal used to monitor tissue ingrowth is contained inside the catheter lumen and does not endanger tissue surrounding the shunt. These results may herald the development of "next generation" shunt technology that allows prediction of malfunction before it affects patient outcome.

  20. Portosystemic shunts for extrahepatic portal hypertension in children.

    Science.gov (United States)

    Tocornal, J; Cruz, F

    1981-07-01

    Twenty-three children with prehepatic portal hypertension and hemorrhage due to ruptured esophagogastric varices had portosystemic shunts. Their ages ranged from two years and seven months to 15 years. Eleven were less than eight years of age. Twenty patients had portal vein cavernomatosis and three patients had double portal veins. In 21 patients, a mesocaval type of shunt was done. A splenorenal shunt was performed in two. There was no surgical mortality. Two shunts occluded, both in rather young infants--two years and seven months and three years of age. In all the others, there was no further bleeding, and the shunts remained patent, as shown by abdominal angiograms. Neuropsychiatric disorders, probably due to hepatic encephalopathy, occurred in only one patient. On the basis of this favorable experience, we believe that an elective portosystemic shunt should, in general, be performed upon children with prehepatic portal hypertension after one major variceal hemorrhage. We favor a mesocaval type of shunt in these children because of the larger diameter of the vessels involved in the anastomosis and because it preserves the spleen, maintaining defense against subsequent infection.

  1. Research on spark discharge of floating roof tank shunt

    International Nuclear Information System (INIS)

    Bi, Xiaolei; Liu, Quanzhen; Liu, Baoquan; Gao, Xin; Hu, Haiyan; Liu, Juan

    2013-01-01

    In order to quantitatively analyze the spark discharge risk of floating roof tank shunts, the breakdown voltage of shunt has been calculated by Townsend theory, the shunt spark discharge experiment is carried out by using 1.2/50 μs impulse voltage wave, and the relationship between breakdown voltage of shunt spark discharge and air gap is analyzed. It has been indicated by theoretical analysis and experimental study that the small gap is more easily cause spark discharge than the big gap when the contact between shunt and tank shell is poor. When air gap distance is equal to 0.1 cm, average breakdown voltage is 5280 V. When the air gap distance is less than 0.3 cm, experiment data agree well with Townsend theory. Therefore, in the condition of small gap, Townsend theory can be used to calculated breakdown voltage of shunt. Finally, based on the above conclusions, improvements for avoiding the spark discharge risk of shunt of floating roof tanks have been proposed.

  2. Spinal cord arteriovenous shunts: from imaging to management

    International Nuclear Information System (INIS)

    Rodesch, G.; Lasjaunias, P.

    2003-01-01

    Spinal cord arteriovenous shunts (SCAVSs) are either fistulas or niduses that can be separated in four different groups according to their localization and relationship to the dura. Paraspinal AVSs are located outside the spine and are responsible for neurological symptoms because of cord compression by ertatic veins, venous congestion or arterial steal. Epidural shunts are located in the epidural space and drain in epidural veins with secondary intradural congestion. Dural shunts are embedded in the dura, produce a cord venous myelopathy after draining through veins that either pierce the dura far from a nerve root or accompany a nerve root. Intradural shunts affect the cord, the roots or the filum. Additionally, they can be classified according to their potential relationships with genetics, vascular biological features and angiogenesis into genetic hereditary lesions (hereditary hemorrhagic telangiectasia), genetic non-hereditary lesions (multiple lesions with metameric links) and single lesions (AVMs or micro AVFs). MRI and MRA are able to visualise SCAVS early after the onset of clinical symptoms. The type of shunt and its localization may remain difficult to be precise. Angiography remains the gold standard for analysis of the anatomical, morphological and architectural features necessary for therapeutic decisions in both paediatric and adult populations. In our series, embolisation is chosen in first intention whatever the type of shunt responsible for the clinical symptoms and glue is preferably used. In paraspinal, dural or epidural arteriovenous shunts, the goal of treatment should be complete closure of the shunt. A complete cure by embolization is rather easily achieved in paraspinal lesions. Failure of endovascular therapy in dural or epidural shunts must bring the patient to surgery. The prognosis of most intradural shunts seems better than previously thought, even after haemorrhage. In intradural spinal cord arteriovenous shunts, embolisation

  3. Endoscopic Third Ventriculostomy in Previously Shunted Children

    Directory of Open Access Journals (Sweden)

    Eva Brichtova

    2013-01-01

    Full Text Available Endoscopic third ventriculostomy (ETV is a routine and safe procedure for therapy of obstructive hydrocephalus. The aim of our study is to evaluate ETV success rate in therapy of obstructive hydrocephalus in pediatric patients formerly treated by ventriculoperitoneal (V-P shunt implantation. From 2001 till 2011, ETV was performed in 42 patients with former V-P drainage implantation. In all patients, the obstruction in aqueduct or outflow parts of the fourth ventricle was proved by MRI. During the surgery, V-P shunt was clipped and ETV was performed. In case of favourable clinical state and MRI functional stoma, the V-P shunt has been removed 3 months after ETV. These patients with V-P shunt possible removing were evaluated as successful. In our group of 42 patients we were successful in 29 patients (69%. There were two serious complications (4.7%—one patient died 2.5 years and one patient died 1 year after surgery in consequence of delayed ETV failure. ETV is the method of choice in obstructive hydrocephalus even in patients with former V-P shunt implantation. In case of acute or scheduled V-P shunt surgical revision, MRI is feasible, and if ventricular system obstruction is diagnosed, the hydrocephalus may be solved endoscopically.

  4. Evaluation of Blalock-Taussig shunts using magnetic resonance imaging

    International Nuclear Information System (INIS)

    Okajima, Yoshitomo; Tashima, Kazuyuki; Terai, Masaru; Niwa, Koichirou.

    1988-01-01

    Four patients aged 3 to 18 months (mean 13 months) with a total of five Blalock-Taussig shunts (BT shunts; two were original BT shunts and three were modified BT shunts using GOLASKI grafts) underwent evaluation by ECG-gated magnetic resonance imaging. There were two cases with pulmonary atresia with intact ventricular septum, one with double outlet right ventricle with pulmonary stenosis and one with tetralogy of Fallot with pulmonary atresia who underwent bilateral BT shunts. At the time of study, an auscultory shunt murmur was audible in all patients. The magnetic resonance images were obtained with a Picker International Vista MR with a superconducting magnet operating at 0.5 Tesla. A spin echo sequence (echo time 40 msec) was used. All patients were placed within a 30 cm head coil radio antenna and sedated with chloral hydrate or diazepam. Four of 5 shunts were imaged on both coronal sections and sagittal sections during enddiastole. And there was no signal within the grafts. When the velocity of blood flow is beyond the cutoff velocity, the signal intensity of flowing blood is near background level. So we judged these grafts were patient. Our results showed that MRI was a very useful noninvasive method for evaluation of BT shunts. (author)

  5. Evaluation of Blalock-Taussig shunts using magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Okajima, Yoshitomo; Tashima, Kazuyuki; Terai, Masaru; Niwa, Koichirou.

    1988-10-01

    Four patients aged 3 to 18 months (mean 13 months) with a total of five Blalock-Taussig shunts (BT shunts; two were original BT shunts and three were modified BT shunts using GOLASKI grafts) underwent evaluation by ECG-gated magnetic resonance imaging. There were two cases with pulmonary atresia with intact ventricular septum, one with double outlet right ventricle with pulmonary stenosis and one with tetralogy of Fallot with pulmonary atresia who underwent bilateral BT shunts. At the time of study, an auscultory shunt murmur was audible in all patients. The magnetic resonance images were obtained with a Picker International Vista MR with a superconducting magnet operating at 0.5 Tesla. A spin echo sequence (echo time 40 msec) was used. All patients were placed within a 30 cm head coil radio antenna and sedated with chloral hydrate or diazepam. Four of 5 shunts were imaged on both coronal sections and sagittal sections during enddiastole. And there was no signal within the grafts. When the velocity of blood flow is beyond the cutoff velocity, the signal intensity of flowing blood is near background level. So we judged these grafts were patient. Our results showed that MRI was a very useful noninvasive method for evaluation of BT shunts.

  6. Treatment of refractory chylothorax with externalized pleuroperitoneal shunts in children.

    Science.gov (United States)

    Wolff, A B; Silen, M L; Kokoska, E R; Rodgers, B M

    1999-09-01

    Traditional therapy for refractory chylothorax in the pediatric population has included pleurodesis and thoracic duct ligation. These procedures are associated with high morbidity and questionable success rates. We retrospectively reviewed our experience with 15 patients who underwent treatment for chylous effusions using pleuroperitoneal shunts with exteriorized pump chambers. Mean patient age at time of shunt placement was 2.1 (0.1 to 11.5) years and the most common indication (7 of 15) was refractory chylothorax following surgical correction of congenital heart disease. Mean chylothorax duration before shunt placement was 76 (5 to 810) days and shunts were in place for an average of 104 (12 to 365) days. A total of 19 chylous effusions (pleural or pericardial) were treated with shunts. Nine of 11 right-sided chylothoraces, 5 of 6 left-sided chylothoraces, and 2 of 2 chylopericardia resolved with shunt therapy (84% total). Pleuroperitoneal shunting failed to clear the effusion in 3 children. There were six episodes of shunt malfunction that were repaired and two episodes of infection. Inguinal or umbilical hernia developed in 4 patients. Externalized pleuroperitoneal shunting is a safe, effective, and minimally invasive treatment for children with refractory chylous effusions.

  7. Ventriculoperitoneal shunt infection in Haji Adam Malik Hospital, Medan

    Science.gov (United States)

    Dharmajaya, R.

    2018-03-01

    Installation of ventriculoperitoneal shunts (VP) represented a substantial progress in the neurosurgical management of hydrocephalus in children. However, infection is the most commonpostoperative complication of aventriculoperitoneal shunt. It is important because it is related to substantial morbidity and mortality, and exerts a negative impact on the quality of life of patients. We retrospectively analyzed all 20 cases of shunt infection from 2013 to 2016. The types of infections found were exposed shunts15 cases (75%), and 5 cases of ventriculitis (25%). Length of infection time which calculated from the beginning of surgery was 350.20 days or 11 months. The most common pathogen types are S. epidermidis followed by P. aeruginosa, E. coli, and A. baumanii. There were many risk factors for shunt infection, but the interesting fact was the level of pre-operative albumin. There was a significant difference between low albumin levels (<3.0) and normal albumin (≥3.0) levels against the risk of exposure shunt, p = 0.015. It means there is asignificant difference between low pre-operative albumin and normal level for the risk of theexposed shunt.

  8. Characterization of the coagulation profile in children with liver disease and extrahepatic portal vein obstruction or shunt.

    Science.gov (United States)

    Beattie, William; Magnusson, Maria; Hardikar, Winita; Monagle, Paul; Ignjatovic, Vera

    2017-03-01

    Chronic liver disease causes a disruption of procoagulant and anticoagulant factors, resulting in a fragile state, prone to increased rates of both bleeding and thrombosis. Currently, there is limited literature describing the changes observed in pediatric liver disease and extrahepatic portal vein obstruction or shunt. This study aimed to describe the changes that occur in children with chronic liver disease and extrahepatic portal vein obstruction or shunt. We measured the concentration and activity of key procoagulant and anticoagulant factors in children with liver disease, children with extrahepatic portal vein obstruction or shunt, and healthy children. Children with severe liver disease had coagulopathic changes, including either decreased concentration or activity of factor II, factor V, and factor VII. Nineteen percent (8/42) of the cohort had significant bleeding. Thrombophilic changes were also observed, including decreased concentration or activity of protein C, protein S, and antithrombin and increased concentration and activity of factor VIII and Von Willebrand factor. Similar coagulation factor changes were observed in children with extrahepatic portal vein obstruction or shunt. There was a trend toward greater changes in coagulation factor activity compared to concentration. This study provides a detailed description of the changes in both the concentration and activity of coagulation factors in pediatric liver disease and extrahepatic portal vein obstruction or shunt. Interestingly, procoagulant and anticoagulant factors were deranged in portal vein obstruction or shunt to a similar degree as in liver disease. An improved understanding of the coagulation profile in the pediatric setting will contribute to the improved management of liver disease and extrahepatic portal obstruction or shunt. PELD: pediatric end-stage liver disease score; MELD: model for end-stage liver disease score; ELISA: enzyme-linked immunosorbent assay; MCRI: Murdoch Childrens

  9. The somatic shunt cable model for neurons.

    OpenAIRE

    Durand, D

    1984-01-01

    The derivation of the equations for an electrical model of nerve cells is presented. The model consists of an equivalent cylinder, a lumped somatic impedance, and a variable shunt at the soma. This shunt was introduced to take into account the fast voltage decays observed following the injections of current pulses in some motoneurons and hippocampal granule cells that could not be explained by existing models. The shunt can be interpreted either by penetration damage with the electrode or by ...

  10. Simulation model for port shunting yards

    Science.gov (United States)

    Rusca, A.; Popa, M.; Rosca, E.; Rosca, M.; Dragu, V.; Rusca, F.

    2016-08-01

    Sea ports are important nodes in the supply chain, joining two high capacity transport modes: rail and maritime transport. The huge cargo flows transiting port requires high capacity construction and installation such as berths, large capacity cranes, respectively shunting yards. However, the port shunting yards specificity raises several problems such as: limited access since these are terminus stations for rail network, the in-output of large transit flows of cargo relatively to the scarcity of the departure/arrival of a ship, as well as limited land availability for implementing solutions to serve these flows. It is necessary to identify technological solutions that lead to an answer to these problems. The paper proposed a simulation model developed with ARENA computer simulation software suitable for shunting yards which serve sea ports with access to the rail network. Are investigates the principal aspects of shunting yards and adequate measures to increase their transit capacity. The operation capacity for shunting yards sub-system is assessed taking in consideration the required operating standards and the measure of performance (e.g. waiting time for freight wagons, number of railway line in station, storage area, etc.) of the railway station are computed. The conclusion and results, drawn from simulation, help transports and logistics specialists to test the proposals for improving the port management.

  11. Shunt protection for superconducting Maglev magnets

    Energy Technology Data Exchange (ETDEWEB)

    Atherton, D L [Queen' s Univ., Kingston, Ontario (Canada). Dept. of Physics

    1979-09-01

    Closely coupled, short-circuited shunt coils are proposed for quench protection of superconducting Maglev magnets which use high resistance, matrix composite conductors. It is shown that, by suitable design, the shunts can reduce induced ac losses and that the changing currents during magnet energization or vehicle lift off and landing can be tolerated.

  12. Effect of electromagnetic navigated ventriculoperitoneal shunt placement on failure rates.

    Science.gov (United States)

    Jung, Nayoung; Kim, Dongwon

    2013-03-01

    To evaluate the effect of electromagnetic (EM) navigation system on ventriculoperitoneal (VP) shunt failure rate through comparing the result of standard shunt placement. All patients undergoing VP shunt from October 2007 to September 2010 were included in this retrospective study. The first group received shunt surgery using EM navigation. The second group had catheters inserted using manual method with anatomical landmark. The relationship between proximal catheter position and shunt revision rate was evaluated using postoperative computed tomography by a 3-point scale. 1) Grade I; optimal position free-floating in cerebrospinal fluid, 2) Grade II; touching choroid or ventricular wall, 3) Grade III; tip within parenchyma. A total of 72 patients were participated, 27 with EM navigated shunts and 45 with standard shunts. Grade I was found in 25 patients from group 1 and 32 patients from group 2. Only 2 patients without use of navigation belonged to grade III. Proximal obstruction took place 7% in grade I, 15% in grade II and 100% in grade III. Shunt revision occurred in 11% of group 1 and 31% of group 2. Compared in terms of proximal catheter position, there was growing trend of revision rate according to increase of grade on each group. Although infection rate was similar between both groups, the result had no statistical meaning (p=0.905, chi-square test). The use of EM navigation in routine shunt surgery can eliminate poor shunt placement resulting in a dramatic reduction in failure rates.

  13. Shunt protection for superconducting Maglev magnets

    International Nuclear Information System (INIS)

    Atherton, D.L.

    1979-01-01

    Closely coupled, short-circuited shunt coils are proposed for quench protection of superconducting Maglev magnets which use high resistance, matrix composite conductors. It is shown that, by suitable design, the shunts can reduce induced ac losses and that the changing currents during magnet energization or vehicle lift off and landing can be tolerated. (author)

  14. Percutaneous peritoneovenous shunt positioning: technique and preliminary results

    International Nuclear Information System (INIS)

    Orsi, Franco; Grasso, Rosario Francesco; Bonomo, Guido; Marinucci, Irene; Monti, Cinzia; Bellomi, Massimo

    2002-01-01

    Nine peritoneovenous shunts were positioned by percutaneous technique in seven patients with advanced malignancy causing severe refractory ascites, and in two patients with hepatic cirrhosis (one with hepatocarcinoma). In all patients the shunts were percutaneously placed through the subclavian vein in the angiographic suite under digital fluoroscopic guide. No complications directly related to the procedure occurred. The shunt was successfully positioned in all patients in 60 min average time. No patient showed symptoms related to pulmonary overload or to disseminated intravascular coagulation. All patients had a significant improvement of the objective symptoms related to ascites such as respiratory symptoms, dyspepsia, and functional impairment to evacuation describing an improvement of their quality of life. Maximum shunt patency was 273 days. Percutaneous placement of peritoneovenous shunt is a safe, fast, and inexpensive procedure, extremely useful in resolution of refractory ascites, reducing symptoms, and allowing effective palliation, with a great improvement in quality of life. (orig.)

  15. Percutaneous peritoneovenous shunt positioning: technique and preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Orsi, Franco; Grasso, Rosario Francesco; Bonomo, Guido; Marinucci, Irene [Division of Radiology, European Institute of Oncology, Milan (Italy); Monti, Cinzia [Institute of Radiology, University of Milan (Italy); Bellomi, Massimo [Division of Radiology, European Institute of Oncology, Milan (Italy); Institute of Radiology, University of Milan (Italy)

    2002-05-01

    Nine peritoneovenous shunts were positioned by percutaneous technique in seven patients with advanced malignancy causing severe refractory ascites, and in two patients with hepatic cirrhosis (one with hepatocarcinoma). In all patients the shunts were percutaneously placed through the subclavian vein in the angiographic suite under digital fluoroscopic guide. No complications directly related to the procedure occurred. The shunt was successfully positioned in all patients in 60 min average time. No patient showed symptoms related to pulmonary overload or to disseminated intravascular coagulation. All patients had a significant improvement of the objective symptoms related to ascites such as respiratory symptoms, dyspepsia, and functional impairment to evacuation describing an improvement of their quality of life. Maximum shunt patency was 273 days. Percutaneous placement of peritoneovenous shunt is a safe, fast, and inexpensive procedure, extremely useful in resolution of refractory ascites, reducing symptoms, and allowing effective palliation, with a great improvement in quality of life. (orig.)

  16. Radiologic follow-up of the transjugular intrahepatic stent-shunt (TIPSS)

    International Nuclear Information System (INIS)

    Hansmann, H.J.; Noeldge, G.; Leutloff, U.; Radeleff, B.; Richter, G.M.

    2001-01-01

    The transjugular intrahepatic stent-shunt (TIPSS) is a well accepted minimal invasive therapy for complications of portal hypertension: recurrent variceal bleeding, refractory ascites and liver failure due to the Budd-Chiari syndrome. The high frequency of shunt stenoses and occlusions makes regular follow up examinations essential. Despite modern non invasive imaging methods direct portography still is the gold standard for shunt surveillance in TIPSS. Ultrasound is helpful to detect shunt dysfunction, but nevertheless its failure rate is considerable despite the use of contrast enhancers such as Levovist because of anatomic and physical limitations, particularly when TIPSS-tracts deep in the liver are present. Reintervention rates approach 90-100% after 24 months, with 100% in child's A patients with comparatively good liver function. However, a strict shunt surveillance program with early portography and reintervention when necessary guarantees high clinical success rates associated with very low rebleeding rates below 10%. Overall the secondary success rate is 80%. Secondary failures are mainly caused by lack of patient compliance during follow-up. In a subgroup of patients no shunt maturation is observed, requiring multiple shunt revisions. In cases of recurrent shunt occlusions an association with bile leaks is presumed. In selected cases patients with chronically recurrent shunt stenosis or occlusions may benefit from placement of TIPSS stent grafts. (orig.) [de

  17. Aqueous shunts for glaucoma.

    Science.gov (United States)

    Tseng, Victoria L; Coleman, Anne L; Chang, Melinda Y; Caprioli, Joseph

    2017-07-28

    Aqueous shunts are employed to control intraocular pressure (IOP) for people with primary or secondary glaucomas who fail or are not candidates for standard surgery. To assess the effectiveness and safety of aqueous shunts for reducing IOP in glaucoma compared with standard surgery, another type of aqueous shunt, or modification to the aqueous shunt procedure. We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 8), MEDLINE Ovid (1946 to August 2016), Embase.com (1947 to August 2016), PubMed (1948 to August 2016), LILACS (Latin American and Caribbean Health Sciences Literature Database) (1982 to August 2016), ClinicalTrials.gov (www.clinicaltrials.gov); searched 15 August 2016, and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en); searched 15 August 2016. We did not use any date or language restrictions in the electronic search for trials. We last searched the electronic databases on 15 August 2016. We also searched the reference lists of identified trial reports and the Science Citation Index to find additional trials. We included randomized controlled trials that compared various types of aqueous shunts with standard surgery or to each other in eyes with glaucoma. Two review authors independently screened search results for eligibility, assessed the risk of bias, and extracted data from included trials. We contacted trial investigators when data were unclear or not reported. We graded the certainty of the evidence using the GRADE approach. We followed standard methods as recommended by Cochrane. We included 27 trials with a total of 2099 participants with mixed diagnoses and comparisons of interventions. Seventeen studies reported adequate methods of randomization, and seven reported adequate allocation concealment. Data collection and follow-up times varied.Four trials compared an aqueous shunt (Ahmed or Baerveldt) with trabeculectomy, of which

  18. Resident-performed Ex-PRESS shunt implantation versus trabeculectomy.

    Science.gov (United States)

    Seider, Michael I; Rofagha, Soraya; Lin, Shan C; Stamper, Robert L

    2012-09-01

    To compare outcomes between resident-performed trabeculectomy and Ex-PRESS shunt implantation. A consecutive cohort of 36 Ex-PRESS shunt implantations and 57 trabeculectomies (1 eye/patient) performed by resident surgeons in their third year of ophthalmic training at the University of California, San Francisco and at the San Francisco Veterans Administration Hospital, under the supervision of a single glaucoma fellowship-trained surgeon were included in this study. Eyes with PRESS shunt groups at all follow-up points. On average, the Ex-PRESS shunt group required significantly less ocular antihypertensive medication to control IOP at 3 months postoperative (P=0.01), but no difference was found at 6 months or 1 year (all, P≥0.28). A larger proportion of Ex-PRESS shunt patients had good IOP control without medication at 3 (P=0.057) and 6 months (P=0.076) postoperatively. No difference was found in the rates of sight-threatening complications between groups (all, P≥0.22). In the hands of ophthalmology residents in their third year of training, the trabeculectomy and Ex-PRESS shunt implantation procedures perform comparably in terms of postoperative IOP control, reduction in patient dependence on ocular antihypertensive medications, and risk of complication in our population.

  19. Catalytic asymmetric Meerwein-Ponndorf-Verley reduction of glyoxylates induced by a chiral N,N'-dioxide/Y(OTf)3 complex.

    Science.gov (United States)

    Wu, Wangbin; Zou, Sijia; Lin, Lili; Ji, Jie; Zhang, Yuheng; Ma, Baiwei; Liu, Xiaohua; Feng, Xiaoming

    2017-03-18

    An asymmetric Meerwein-Ponndorf-Verley (MPV) reduction of glyoxylates was for the first time accomplished via an N,N'-dioxide/Y(OTf) 3 complex with aluminium alkoxide and molecular sieves (MSs) as crucial additives. A variety of optically active α-hydroxyesters were obtained with excellent results. A possible reaction mechanism was proposed based on the experiments.

  20. Investigating PID Shunting in Polycrystalline Silicon Modules via Multiscale, Multitechnique Characterization

    Energy Technology Data Exchange (ETDEWEB)

    Harvey, Steven P [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Moseley, John [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Norman, Andrew [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Hacke, Peter L [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Johnston, Steven [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Al-Jassim, Mowafak M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Stokes, Adam [Colorado School of Mines; Gorman, Brian [Colorado School of Mines

    2018-02-27

    We investigated the potential-induced degradation (PID) shunting mechanism in multicrystalline-silicon photovoltaic modules by using a multiscale, multitechnique characterization approach. Both field-stressed modules and laboratory-stressed mini modules were studied. We used photoluminescence, electroluminescence, and dark lock-in thermography imaging to identify degraded areas at the module scale. Small samples were then removed from degraded areas, laser marked, and imaged by scanning electron microscopy. We used simultaneous electron-beam induced current imaging and focused ion beam milling to mark around PID shunts for chemical analysis by time-of-flight secondary-ion mass spectrometry or to isolate individual shunt defects for transmission electron microscopy and atom-probe tomography analysis. By spanning a range of 10 orders of magnitude in size, this approach enabled us to investigate the root-cause mechanisms for PID shunting. We observed a direct correlation between recombination active shunts and sodium content. The sodium content in shunted areas peaks at the SiNX/Si interface and is consistently observed at a concentration of 0.1% to 2% in shunted areas. Analysis of samples subjected to PID recovery, either activated by electron beam or thermal effects only, reveals that recovery of isolated shunts correlates with diffusion of sodium out of the structural defects to the silicon surface. We observed the role of oxygen and chlorine in PID shunting and found that those species - although sometimes present in structural defects where PID shunting was observed - do not play a consistent role in PID shunting.

  1. Assessment Lumboperitoneal or Ventriculoperitoneal Shunt Patency by Radionuclide Technique: A Review Experience Cases

    International Nuclear Information System (INIS)

    Chiewvit, Sunanta; Nuntaaree, Sarun; Kanchaanapiboon, Potjanee; Chiewvit, Pipat

    2014-01-01

    Hydrocephalus-related symptoms that worsen after shunt placement may indicate a malfunctioning or obstructed shunt. The assessment of shunt patency and site of obstruction is important for planning of treatment. The radionuclide cerebrospinal fluid (CSF) shunt study provides a simple, effective, and low-radiation-dose method of assessing CSF shunt patency. The radionuclide CSF shuntography is a useful tool in the management of patients presenting with shunt-related problems not elucidated by conventional radiological examination. This article described the imaging technique of ventriculoperitoneal (VP) shunt and lumbar puncture (LP) shunt. The normal finding, abnormal finding of completed obstruction and partial obstruction is present by our cases experience. The radiopharmaceutical (Tc-99m diethylenetriaminepentaacetic acid) was injected via the reservoir for VP shunt and via lumbar puncture needle in subarachnoid space for LP shunt, then serial image in the head and abdominal area. The normal function of VP and LP shunt usually rapid spillage of the radioactivity in the abdominal cavity diffusely. The patent proximal tube VP shunt demonstrates ventricular reflux. The early image of patent LP shunt reveals no activity in the ventricular system contrast to distal LP shunt reveals early reflux of activity in the ventricular system. The completed distal VP and LP shunt obstruction show absence of tracer in the peritoneal area or markedly delayed appearance of abdominal activity. The partial distal VP and LP shunt obstruction recognized by slow transit or accumulation of tracer at the distal end or focal tracer in the peritoneal cavity near the tip of distal shunt. The images of the normal and abnormal CSF shunt as describe before are present in the full paper. Radionuclide CSF shuntography is a reliable and simple procedure for assessment shunt patency

  2. Hydrocephalus and Shunts

    Science.gov (United States)

    ... of a problem. Because of the complexity, a neurosurgeon is the best person to diagnosis and treat ... type of shunt is best for whom. So neurosurgeons usually pick ones that they think are best. ...

  3. Application of high-performance liquid chromatography to the determination of glyoxylate synthesis in chick embryo liver.

    Science.gov (United States)

    Qureshi, A A; Elson, C E; Lebeck, L A

    1982-11-19

    The isolation and identification of three major alpha-keto end products (glyoxylate, pyruvate, alpha-ketoglutarate) of the isocitrate lyase reaction in 18-day chick embryo liver have been described. This was accomplished by the separation of these alpha-keto acids as their 2,4-dinitrophenylhydrazones (DNPHs) by high-performance liquid chromatography (HPLC). The DNPHs of alpha-keto acids were eluted with an isocratic solvent system of methanol-water-acetic acid (60:38.5:1.5) containing 5 mM tetrabutylammonium phosphate from a reversed-phase ultrasphere C18 (IP) and from a radial compression C18 column. The separation can be completed on the radial compression column within 15-20 min as compared to 30-40 min with a conventional reversed-phase column. Retention times and peak areas were integrated for both the assay samples and reference compounds. A relative measure of alpha-keto acid in the peak was calculated by comparison with the standard. The identification of each peak was done on the basis of retention time matching, co-chromatography with authentic compounds, and stopped flow UV-VIS scanning between 240 and 440 nm. Glyoxylate represented 5% of the total product of the isocitrate lyase reaction. Day 18 parallels the peak period of embryonic hepatic glycogenesis which occurs at a time when the original egg glucose reserve has been depleted.

  4. Cross-species functionality of pararetroviral elements driving ribosome shunting.

    Directory of Open Access Journals (Sweden)

    Mikhail M Pooggin

    Full Text Available BACKGROUND: Cauliflower mosaic virus (CaMV and Rice tungro bacilliform virus (RTBV belong to distinct genera of pararetroviruses infecting dicot and monocot plants, respectively. In both viruses, polycistronic translation of pregenomic (pg RNA is initiated by shunting ribosomes that bypass a large region of the pgRNA leader with several short (sORFs and a stable stem-loop structure. The shunt requires translation of a 5'-proximal sORF terminating near the stem. In CaMV, mutations knocking out this sORF nearly abolish shunting and virus viability. METHODOLOGY/PRINCIPAL FINDINGS: Here we show that two distant regions of the CaMV leader that form a minimal shunt configuration comprising the sORF, a bottom part of the stem, and a shunt landing sequence can be replaced by heterologous sequences that form a structurally similar configuration in RTBV without any dramatic effect on shunt-mediated translation and CaMV infectivity. The CaMV-RTBV chimeric leader sequence was largely stable over five viral passages in turnip plants: a few alterations that did eventually occur in the virus progenies are indicative of fine tuning of the chimeric sequence during adaptation to a new host. CONCLUSIONS/SIGNIFICANCE: Our findings demonstrate cross-species functionality of pararetroviral cis-elements driving ribosome shunting and evolutionary conservation of the shunt mechanism. We are grateful to Matthias Müller and Sandra Pauli for technical assistance. This work was initiated at Friedrich Miescher Institute (Basel, Switzerland. We thank Prof. Thomas Boller for hosting the group at the Institute of Botany.

  5. Predicting ventriculoperitoneal shunt infection in children with hydrocephalus using artificial neural network.

    Science.gov (United States)

    Habibi, Zohreh; Ertiaei, Abolhasan; Nikdad, Mohammad Sadegh; Mirmohseni, Atefeh Sadat; Afarideh, Mohsen; Heidari, Vahid; Saberi, Hooshang; Rezaei, Abdolreza Sheikh; Nejat, Farideh

    2016-11-01

    The relationships between shunt infection and predictive factors have not been previously investigated using Artificial Neural Network (ANN) model. The aim of this study was to develop an ANN model to predict shunt infection in a group of children with shunted hydrocephalus. Among more than 800 ventriculoperitoneal shunt procedures which had been performed between April 2000 and April 2011, 68 patients with shunt infection and 80 controls that fulfilled a set of meticulous inclusion/exclusion criteria were consecutively enrolled. Univariate analysis was performed for a long list of risk factors, and those with p value < 0.2 were used to create ANN and logistic regression (LR) models. Five variables including birth weight, age at the first shunting, shunt revision, prematurity, and myelomeningocele were significantly associated with shunt infection via univariate analysis, and two other variables (intraventricular hemorrhage and coincided infections) had a p value of less than 0.2. Using these seven input variables, ANN and LR models predicted shunt infection with an accuracy of 83.1 % (AUC; 91.98 %, 95 % CI) and 55.7 % (AUC; 76.5, 95 % CI), respectively. The contribution of the factors in the predictive performance of ANN in descending order was history of shunt revision, low birth weight (under 2000 g), history of prematurity, the age at the first shunt procedure, history of intraventricular hemorrhage, history of myelomeningocele, and coinfection. The findings show that artificial neural networks can predict shunt infection with a high level of accuracy in children with shunted hydrocephalus. Also, the contribution of different risk factors in the prediction of shunt infection can be determined using the trained network.

  6. Bacterial contamination of surgeons' gloves during shunt insertion; a pilot study

    DEFF Research Database (Denmark)

    Sørensen, Preben; Ejlertsen, Tove; Aaen, Dorte

    2008-01-01

    Bacterial infection is a major cause of shunt dysfunction. It is well-known that the majority of pathogenic micro-organisms are low-virulent bacteria normally found on intact skin. Probably shunts become contaminated during surgery either by contact to the patient skin, or contact from contaminated...... gloves or instruments. This study was performed to find out to what extent gloves become contaminated during shunt surgery. Gloves used during shunt implantation were examined in 10 operations. Shunt implantation was done using recommended precautions to avoid infection, including prophylactic...... nurse and assistant were contaminated with micro-organisms less than 15 min after surgery has been commenced and before the shunts were handled. This study offers a feasible, simple and logical explanation of how shunts may become contaminated and infected. A simple measure would be to change the outer...

  7. Experience and outcome of ventricular-atrial shunt: a multi centre study

    International Nuclear Information System (INIS)

    Akhtar, N.; Khan, A.A.; Yousaf, M.

    2015-01-01

    Ventriculoperitoneal (VP) shunt has been widely utilized in the treatment of hydrocephalus as a safe option but there is recent literature evidence that ventricularatrial (VA) shunt is not as notorious for its complications as proclaimed, to analyse and report our success with this procedure we conducted our study. Methods: A total of 64 patients undergoing VA shunting were included in this case series study conducted at RMC and Allied hospital Rawalpindi. The data was collected over a period of 4 years from, 1st June 2010 to 1st June 2015. Result: Our study included 64 patients who underwent a VA shunt for hydrocephalus. Their age ranged from 25 to 75 years. Most of the patients were females (60%). The following complications were observed with 2 (3.12%) patients having blockage of the shunt at the neck, 3 (4.68%) suffered from glomerulonephritis, 2 (3.1%) had post-operative neck hematoma, 4 (6.25 %) had wound infection, short lower end of the tube was found in 3 (4.68%), migrated lower end (into the subclavian) was seen in 1 (1.56%). Mortality was 1(1.56%). These results were comparable to other studies. Conclusion: Neurosurgeons have been doing a VA shunt as a second procedure, after a VP shunt when the need due to a complication was encountered. We however share our experience regarding ventriculo-atrial shunting, as first choice procedure, because of its low incidence of shunt blockage unlike VP shunt, which has high rate of shunt blockage and therefore warrants repeated surgeries. (author)

  8. Post V-P shunt surgical site EDH an uncommon complication: case report

    Directory of Open Access Journals (Sweden)

    Garg Manish

    2017-06-01

    Full Text Available ventriculoparitoneal shunt is well established modality of treatment for hydrocephalous. Complication of v-p shunt are also mentioned in literature like shunt infection shunt migration etc [8]. Here we are describing a rare complication of vp shunt which barely mentioned in literature. A 22 yr male admitted with complain of headache & vomiting patient was diagnosed to have tubercular meningities with hydrocephalous. Patient planned for ventriculoparietoneal shunt surgery and vp shunt was done. On 3rd post-surgery day patient develop weakness in Left side of body. Urgent ncct head done which showed EDH at surgical site. Immediate craniotomy and evacuation of hematoma was done patient improved and discharged. Thus we are discussing the importance of meticulous surgery for v-p shunt, post op ct scan and treatment.

  9. Autologous patch graft in tube shunt surgery.

    Science.gov (United States)

    Aslanides, I M; Spaeth, G L; Schmidt, C M; Lanzl, I M; Gandham, S B

    1999-10-01

    To evaluate an alternate method of covering the subconjunctival portion of the tube in aqueous shunt surgery. Evidence of tube erosion, graft-related infection, graft melting, or other associated intraocular complications were evaluated. A retrospective study of 16 patients (17 eyes) who underwent tube shunt surgery at Wills Eye Hospital between July 1991 and October 1996 was conducted. An autologous either "free" or "rotating" scleral lamellar graft was created to cover the subconjunctival portion of the tube shunt. All patients were evaluated for at least 6 months, with a mean follow-up of 14.8 months (range 6-62 months). All eyes tolerated the autologous graft well, with no clinical evidence of tube erosion, or graft-related or intraocular complications. Autologous patch graft in tube shunt surgery appears--in selected cases--to be an effective, safe and inexpensive surgical alternative to allogenic graft materials. It also offers ease of availability, and eliminates the risk of transmitting infectious disease.

  10. Shunt attachment and method for interfacing current collection systems

    Science.gov (United States)

    Denney, Paul E.; Iyer, Natraj C.; Hannan, III, William F.

    1992-01-01

    A composite brush to shunt attachment wherein a volatile component of a composite but mostly metallic brush, used for current collection purposes, does not upon welding or brazing, adversely affect the formation of the interfacial bond with a conductive shunt which carries the current from the zone of the brush. The brush to shunt attachment for a brush material of copper-graphite composite and a shunt of copper, or substituting silver for copper as an alternative, is made through a hot isostatic pressing (HIP). The HIP process includes applying high pressure and temperature simultaneously at the brush to shunt interface, after it has been isolated or canned in a metal casing in which the air adjacent to the interface has been evacuated and the interfacial area has been sealed before the application of pressure and temperature.

  11. Vibration damping with negative capacitance shunts: theory and experiment

    International Nuclear Information System (INIS)

    De Marneffe, B; Preumont, A

    2008-01-01

    This paper analyzes in detail the enhancement of piezoelectric stack transducers by means of the well known 'negative' capacitive shunting. The stability is thoroughly studied: starting from the electrical admittance curve of the transducer, a method is introduced that quantifies the stability margins of the shunted structure. Two different implementations (series vs parallel) are investigated, and the lack of robustness of the parallel one is demonstrated. Next, this technique is experimentally applied on a truss structure. Its performances are compared with those of passive shunt circuits and with those of an active control law, the so-called Integral Force Feedback or IFF. As expected, the damping introduced by the negative capacitance shunt is larger than the damping obtained with the passive shunts; it remains, however, one order of magnitude smaller than that obtained with the IFF

  12. Genetic and Functional Analysis of Congenital Portosystemic Shunts in Dogs

    NARCIS (Netherlands)

    van den Bossche, L.

    2017-01-01

    The general aim of this thesis was to gain further insight into the pathogenesis of congenital portosystemic shunts (CPSS), elucidate mechanisms involved in the pathophysiology of CPSS, and explore predictors of recovery after surgical ligation of the shunt. For intrahepatic portosystemic shunts

  13. Parylene MEMS patency sensor for assessment of hydrocephalus shunt obstruction.

    Science.gov (United States)

    Kim, Brian J; Jin, Willa; Baldwin, Alexander; Yu, Lawrence; Christian, Eisha; Krieger, Mark D; McComb, J Gordon; Meng, Ellis

    2016-10-01

    Neurosurgical ventricular shunts inserted to treat hydrocephalus experience a cumulative failure rate of 80 % over 12 years; obstruction is responsible for most failures with a majority occurring at the proximal catheter. Current diagnosis of shunt malfunction is imprecise and involves neuroimaging studies and shunt tapping, an invasive measurement of intracranial pressure and shunt patency. These patients often present emergently and a delay in care has dire consequences. A microelectromechanical systems (MEMS) patency sensor was developed to enable direct and quantitative tracking of shunt patency in order to detect proximal shunt occlusion prior to the development of clinical symptoms thereby avoiding delays in treatment. The sensor was fabricated on a flexible polymer substrate to eventually allow integration into a shunt. In this study, the sensor was packaged for use with external ventricular drainage systems for clinical validation. Insights into the transduction mechanism of the sensor were obtained. The impact of electrode size, clinically relevant temperatures and flows, and hydrogen peroxide (H2O2) plasma sterilization on sensor function were evaluated. Sensor performance in the presence of static and dynamic obstruction was demonstrated using 3 different models of obstruction. Electrode size was found to have a minimal effect on sensor performance and increased temperature and flow resulted in a slight decrease in the baseline impedance due to an increase in ionic mobility. However, sensor response did not vary within clinically relevant temperature and flow ranges. H2O2 plasma sterilization also had no effect on sensor performance. This low power and simple format sensor was developed with the intention of future integration into shunts for wireless monitoring of shunt state and more importantly, a more accurate and timely diagnosis of shunt failure.

  14. New and improved ways to treat hydrocephalus: Pursuit of a smart shunt.

    Science.gov (United States)

    Lutz, Barry R; Venkataraman, Pranav; Browd, Samuel R

    2013-01-01

    The most common treatment for hydrocephalus is placement of a cerebrospinal fluid shunt to supplement or replace lost drainage capacity. Shunts are life-saving devices but are notorious for high failure rates, difficulty of diagnosing failure, and limited control options. Shunt designs have changed little since their introduction in 1950s, and the few changes introduced have had little to no impact on these long-standing problems. For decades, the community has envisioned a "smart shunt" that could provide advanced control, diagnostics, and communication based on implanted sensors, feedback control, and telemetry. The most emphasized contribution of smart shunts is the potential for advanced control algorithms, such as weaning from shunt dependency and personalized control. With sensor-based control comes the opportunity to provide data to the physician on patient condition and shunt function, perhaps even by a smart phone. An often ignored but highly valuable contribution would be designs that correct the high failure rates of existing shunts. Despite the long history and increasing development activity in the past decade, patients are yet to see a commercialized smart shunt. Most smart shunt development focuses on concepts or on isolated technical features, but successful smart shunt designs will be a balance between technical feasibility, economic viability, and acceptable regulatory risk. Here, we present the status of this effort and a framework for understanding the challenges and opportunities that will guide introduction of smart shunts into patient care.

  15. Coupling slots without shunt impedance drop

    International Nuclear Information System (INIS)

    Balleyguier, P.

    1996-01-01

    It is well known that coupling slots between adjacent cells in a π-mode structure reduce shunt impedance per unit length with respect to single cell cavities. To design optimized coupling slots, one has to answer the following question: for a given coupling factor, what shape, dimension, position and number of slots lead to the lowest shunt impedance drop? A numerical study using the 3D code MAFIA has been carried out. The aim was to design the 352 MHz cavities for the high intensity proton accelerator of the TRISPAL project. The result is an unexpected set of four 'petal' slots. Such slots should lead to a quasi-negligible drop in shunt impedance: about -1% on average, for particle velocity from 0.4 c to 0.8 c. (author)

  16. Shoulder tip pain: an under-reported complication of ventriculoperitoneal shunt.

    LENUS (Irish Health Repository)

    Lim, C

    2012-02-03

    Ventriculoperitoneal (VP) shunt insertion is the commonest form of treatment for hydrocephalus. Shoulder tip pain after VP shunt insertion is unusual and has only recently been reported. We present a case of excruciating shoulder tip pain due to diaphragmatic irritation after VP shunt insertion.

  17. Programmable shunts and headphones: Are they safe together?

    Science.gov (United States)

    Spader, Heather S; Ratanaprasatporn, Linda; Morrison, John F; Grossberg, Jonathan A; Cosgrove, G Rees

    2015-10-01

    Programmable shunts have a valuable role in the treatment of patients with hydrocephalus, but because a magnet is used to change valve settings, interactions with external magnets may reprogram these shunts. Previous studies have demonstrated the ability of magnetic toys and iPads to erroneously reprogram shunts. Headphones are even more ubiquitous, and they contain an electromagnet for sound projection that sits on the head very close to the shunt valve. This study is the first to look at the magnetic field emissions of headphones and their effect on reprogrammable shunt valves to ascertain whether headphones are safe for patients with these shunts to wear. In this in vitro study of the magnetic properties of headphones and their interactions with 3 different programmable shunts, the authors evaluated Apple earbuds, Beats by Dr. Dre, and Bose QuietComfort Acoustic Noise Cancelling headphones. Each headphone was tested for electromagnetic field emissions using a direct current gaussmeter. The following valves were evaluated: Codman Hakim programmable valve, Medtronic Strata II valve, and Aesculap proGAV. Each valve was tested at distances of 0 to 50 mm (in 5-mm increments) from each headphone. The exposure time at each distance was 1 minute, and 3 trials were performed to confirm results at each valve setting and distance. All 3 headphones generated magnetic fields greater than the respective shunt manufacturer's recommended strength of exposure, but these fields did not persist beyond 5 mm. By 2 cm, the fields levels were below 20 G, well below the Medtronic recommendation of 90 G and the Codman recommendation of 80 G. Because the mechanism for the proGAV is different, there is no recommended gauss level. There was no change in gauss-level emissions by the headphones with changes in frequency and amplitude. Both the Strata and Codman-Hakim valves were reprogrammed by direct contact (distance 0 mm) with the Bose headphones. When a rotation component was added, all

  18. Optimization methods for the Train Unit Shunting Problem

    DEFF Research Database (Denmark)

    Haahr, Jørgen Thorlund; Lusby, Richard Martin; Wagenaar, Joris Camiel

    2017-01-01

    We consider the Train Unit Shunting Problem, an important planning problem for passenger railway operators. This problem entails assigning train units from shunting yards to scheduled train services in such a way that the resulting operations are without conflicts. The problem arises at every...... shunting yard in the railway network and involves matching train units to arriving and departing train services as well as assigning the selected matchings to appropriate shunting yard tracks. We present an extensive comparison benchmark of multiple solution approaches for this problem, some of which...... are novel. In particular, we develop a constraint programming formulation, a column generation approach, and a randomized greedy heuristic. We compare and benchmark these approaches with two existing methods, a mixed integer linear program and a two-stage heuristic. The benchmark contains multiple real...

  19. Distal splenorenal shunt with partial spleen resection

    Directory of Open Access Journals (Sweden)

    Gajin Predrag

    2007-01-01

    Full Text Available Introduction: Hypersplenism is a common complication of portal hypertension. Cytopenia in hypersplenism is predominantly caused by splenomegaly. Distal splenorenal shunt (Warren with partial spleen resection is an original surgical technique that regulates cytopenia by reduction of the enlarged spleen. Objective. The aim of our study was to present the advantages of distal splenorenal shunt (Warren with partial spleen resection comparing morbidity and mortality in a group of patients treated by distal splenorenal shunt with partial spleen resection with a group of patients treated only by a distal splenorenal shunt. Method. From 1995 to 2003, 41 patients with portal hypertension were surgically treated due to hypersplenism and oesophageal varices. The first group consisted of 20 patients (11 male, mean age 42.3 years who were treated by distal splenorenal shunt with partial spleen resection. The second group consisted of 21 patients (13 male, mean age 49.4 years that were treated by distal splenorenal shunt only. All patients underwent endoscopy and assessment of oesophageal varices. The size of the spleen was evaluated by ultrasound, CT or by scintigraphy. Angiography was performed in all patients. The platelet and white blood cell count and haemoglobin level were registered. Postoperatively, we noted blood transfusion, complications and total hospital stay. Follow-up period was 12 months, with first checkup after one month. Results In the first group, only one patient had splenomegaly postoperatively (5%, while in the second group there were 13 patients with splenomegaly (68%. Before surgery, the mean platelet count in the first group was 51.6±18.3x109/l, to 118.6±25.4x109/l postoperatively. The mean platelet count in the second group was 67.6±22.8x109/l, to 87.8±32.1x109/l postoperatively. Concerning postoperative splenomegaly, statistically significant difference was noted between the first and the second group (p<0.05. Comparing the

  20. Alanine-glyoxylate aminotransferase 2 (AGXT2 polymorphisms have considerable impact on methylarginine and β-aminoisobutyrate metabolism in healthy volunteers.

    Directory of Open Access Journals (Sweden)

    Anja Kittel

    Full Text Available Elevated plasma concentrations of asymmetric (ADMA and symmetric (SDMA dimethylarginine have repeatedly been linked to adverse clinical outcomes. Both methylarginines are substrates of alanine-glyoxylate aminotransferase 2 (AGXT2. It was the aim of the present study to simultaneously investigate the functional relevance and relative contributions of common AGXT2 single nucleotide polymorphisms (SNPs to plasma and urinary concentrations of methylarginines as well as β-aminoisobutyrate (BAIB, a prototypic substrate of AGXT2. In a cohort of 400 healthy volunteers ADMA, SDMA and BAIB concentrations were determined in plasma and urine using HPLC-MS/MS and were related to the coding AGXT2 SNPs rs37369 (p.Val140Ile and rs16899974 (p.Val498Leu. Volunteers heterozygous or homozygous for the AGXT2 SNP rs37369 had higher SDMA plasma concentrations by 5% and 20% (p = 0.002 as well as higher BAIB concentrations by 54% and 146%, respectively, in plasma and 237% and 1661%, respectively, in urine (both p<0.001. ADMA concentrations were not affected by both SNPs. A haplotype analysis revealed that the second investigated AGXT2 SNP rs16899974, which was not significantly linked to the other AGXT2 SNP, further aggravates the effect of rs37369 with respect to BAIB concentrations in plasma and urine. To investigate the impact of the amino acid exchange p.Val140Ile, we established human embryonic kidney cell lines stably overexpressing wild-type or mutant (p.Val140Ile AGXT2 protein and assessed enzyme activity using BAIB and stable-isotope labeled [²H₆]-SDMA as substrate. In vitro, the amino acid exchange of the mutant protein resulted in a significantly lower enzyme activity compared to wild-type AGXT2 (p<0.05. In silico modeling of the SNPs indicated reduced enzyme stability and substrate binding. In conclusion, SNPs of AGXT2 affect plasma as well as urinary BAIB and SDMA concentrations linking methylarginine metabolism to the common genetic trait of hyper

  1. Diagnosis and epidemiology of red blood cell enzyme disorders

    Directory of Open Access Journals (Sweden)

    Richard Van Wijk

    2013-03-01

    Full Text Available The red blood cell possess an active metabolic machinery that provides the cell with energy to pump ions against electrochemical gradients, to maintain its shape, to keep hemoglobin iron in the reduced (ferrous form, and to maintain enzyme and hemoglobin sulfhydryl groups. The main source of metabolic energy comes from glucose. Glucose is metabolized through the glycolytic pathway and through the hexose monophosphate shunt. Glycolysis catabolizes glucose to pyruvate and lactate, which represent the end products of glucose metabolism in the erythrocyte. Adenosine diphosphate (ADP is phosphorylated to adenosine triphosphate (ATP, and nicotinamide adenine dinucleotide (NAD+ is reduced to NADH in glycolysis. 2,3- Bisphosphoglycerate, an important regulator of the oxygen affinity of hemoglobin, is generated during glycolysis by the Rapoport-Luebering shunt. The hexose monophosphate shunt oxidizes glucose-6-phosphate, reducing NADP+ to reduced nicotinamide adenine dinucleotide phosphate (NADPH. The red cell lacks the capacity for de novo purine synthesis but has a salvage pathway that permits synthesis of purine nucleotides from purine bases...

  2. New and improved ways to treat hydrocephalus: Pursuit of a smart shunt

    Science.gov (United States)

    Lutz, Barry R.; Venkataraman, Pranav; Browd, Samuel R.

    2013-01-01

    The most common treatment for hydrocephalus is placement of a cerebrospinal fluid shunt to supplement or replace lost drainage capacity. Shunts are life-saving devices but are notorious for high failure rates, difficulty of diagnosing failure, and limited control options. Shunt designs have changed little since their introduction in 1950s, and the few changes introduced have had little to no impact on these long-standing problems. For decades, the community has envisioned a “smart shunt” that could provide advanced control, diagnostics, and communication based on implanted sensors, feedback control, and telemetry. The most emphasized contribution of smart shunts is the potential for advanced control algorithms, such as weaning from shunt dependency and personalized control. With sensor-based control comes the opportunity to provide data to the physician on patient condition and shunt function, perhaps even by a smart phone. An often ignored but highly valuable contribution would be designs that correct the high failure rates of existing shunts. Despite the long history and increasing development activity in the past decade, patients are yet to see a commercialized smart shunt. Most smart shunt development focuses on concepts or on isolated technical features, but successful smart shunt designs will be a balance between technical feasibility, economic viability, and acceptable regulatory risk. Here, we present the status of this effort and a framework for understanding the challenges and opportunities that will guide introduction of smart shunts into patient care. PMID:23653889

  3. Predictors of Shunt Dysfunction and Overall Survival in Patients with Variceal Bleeding Treated with Transjugular Portosystemic Shunt Creation Using the Fluency Stent Graft.

    Science.gov (United States)

    Wan, Yue-Meng; Li, Yu-Hua; Xu, Ying; Wu, Hua-Mei; Li, Ying-Chun; Wu, Xi-Nan; Yang, Jin-Hui

    2018-01-16

    Transjugular intrahepatic portosystemic shunt (TIPS) is an established method for portal hypertension. This study was to investigate the long-term safety, technical success, and patency of TIPS, and to determine the risk factors and clinical impacts of shunt dysfunction. A total of 154 consecutive patients undergoing embolotherapy of gastric coronary vein and/or short gastric vein and TIPS creation were prospectively studied. Follow-up data included technical success, patency and revision of TIPS, and overall survival of patients. During the study, the primary and secondary technical success rates were 98.7% and 100%, respectively. Sixty-three patients developed shunt dysfunction, 30 with shunt stenosis and 33 with shunt occlusion. The cumulative 60-month primary, primary assisted, and secondary patency rates were 19.6%, 43.0%, and 93.4%, respectively. The cumulative 60-month overall survival rates were similar between the TIPS dysfunction group and the TIPS non-dysfunction group (68.6% vs. 58.6%, P = .096). Baseline portal vein thrombosis (P value of 8.5 had 77.8% sensitivity and 64.8% specificity. The long-term safety, technical success, and patency of TIPS were good; baseline portal vein thrombosis, use of bare stents, and PPG were significantly associated with shunt dysfunction; shunt dysfunction has little impact on patients' long-term survival because of high secondary patency rates. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  4. Risk factors for shunt malfunction in pediatric hydrocephalus: a multicenter prospective cohort study.

    Science.gov (United States)

    Riva-Cambrin, Jay; Kestle, John R W; Holubkov, Richard; Butler, Jerry; Kulkarni, Abhaya V; Drake, James; Whitehead, William E; Wellons, John C; Shannon, Chevis N; Tamber, Mandeep S; Limbrick, David D; Rozzelle, Curtis; Browd, Samuel R; Simon, Tamara D

    2016-04-01

    OBJECT The rate of CSF shunt failure remains unacceptably high. The Hydrocephalus Clinical Research Network (HCRN) conducted a comprehensive prospective observational study of hydrocephalus management, the aim of which was to isolate specific risk factors for shunt failure. METHODS The study followed all first-time shunt insertions in children younger than 19 years at 6 HCRN centers. The HCRN Investigator Committee selected, a priori, 21 variables to be examined, including clinical, radiographic, and shunt design variables. Shunt failure was defined as shunt revision, subsequent endoscopic third ventriculostomy, or shunt infection. Important a priori-defined risk factors as well as those significant in univariate analyses were then tested for independence using multivariate Cox proportional hazard modeling. RESULTS A total of 1036 children underwent initial CSF shunt placement between April 2008 and December 2011. Of these, 344 patients experienced shunt failure, including 265 malfunctions and 79 infections. The mean and median length of follow-up for the entire cohort was 400 days and 264 days, respectively. The Cox model found that age younger than 6 months at first shunt placement (HR 1.6 [95% CI 1.1-2.1]), a cardiac comorbidity (HR 1.4 [95% CI 1.0-2.1]), and endoscopic placement (HR 1.9 [95% CI 1.2-2.9]) were independently associated with reduced shunt survival. The following had no independent associations with shunt survival: etiology, payer, center, valve design, valve programmability, the use of ultrasound or stereotactic guidance, and surgeon experience and volume. CONCLUSIONS This is the largest prospective study reported on children with CSF shunts for hydrocephalus. It confirms that a young age and the use of the endoscope are risk factors for first shunt failure and that valve type has no impact. A new risk factor-an existing cardiac comorbidity-was also associated with shunt failure.

  5. A plasma polymerization technique to overcome cerebrospinal fluid shunt infections

    Energy Technology Data Exchange (ETDEWEB)

    Coekeliler, D [Plasma Aided Bioengineering and Biotechnology Research Laboratory, Engineering Faculty, Hacettepe University, 06532, Ankara (Turkey); Caner, H [Department of Neurosurgery, School of Medicine, Baskent University, 06610, Ankara (Turkey); Zemek, J [Institute of Physics, Academy of Sciences of the Czech Republic, Cukrovarnicka 10, 162 53, Prague, Czech Republic (Czech Republic); Choukourov, A [Department of Macromolecular Physics, Charles University, V Holesovickach 2, 18000 Prague (Czech Republic); Biederman, H [Department of Macromolecular Physics, Charles University, V Holesovickach 2, 18000 Prague (Czech Republic); Mutlu, M [Plasma Aided Bioengineering and Biotechnology Research Laboratory, Engineering Faculty, Hacettepe University, 06532, Ankara (Turkey)

    2007-03-01

    Prosthetic devices, mainly shunts, are frequently used for temporary or permanent drainage of cerebrospinal fluid. The pathogenesis of shunt infection is a very important problem in modern medicine and generally this is characterized by staphylococcal adhesion to the cerebrospinal fluid shunt surfaces. In this paper, the prevention of the attachment of test microorganism Staphylococcus epidermidis on the cerebrospinal fluid shunt surfaces by 2-hydroxyethylmethacrylate (HEMA) precursor modification in the plasma polymerization system, is reported. Different plasma polymerization conditions (RF discharge power 10-20-30 W, exposure time 5-10-15 min) were employed during the surface modification. The surface chemistry and topology of unmodified and modified shunts was characterized by x-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM) and atomic force microscopy (AFM). Also, static contact angle measurements were performed to state the change of surface hydrophilicity. All samples were tested in vitro with Staphylococcus epidermidis. A plasma-polymerized HEMA film (PP HEMA) was found to be an alternative simple method to decrease the microorganism attachment and create bacterial anti-fouling surfaces. The attachment of the model microorganism Staphylococcus epidermidis on the shunt surface modified by PP HEMA at 20 W and 15 min was reduced 62.3% if compared to the unmodified control surface of the shunt.

  6. Aberrant hepatic lipid storage and metabolism in canine portosystemic shunts.

    Science.gov (United States)

    Van den Bossche, Lindsay; Schoonenberg, Vivien A C; Burgener, Iwan A; Penning, Louis C; Schrall, Ingrid M; Kruitwagen, Hedwig S; van Wolferen, Monique E; Grinwis, Guy C M; Kummeling, Anne; Rothuizen, Jan; van Velzen, Jeroen F; Stathonikos, Nikolas; Molenaar, Martijn R; Helms, Bernd J; Brouwers, Jos F H M; Spee, Bart; van Steenbeek, Frank G

    2017-01-01

    Non-alcoholic fatty liver disease (NAFLD) is a poorly understood multifactorial pandemic disorder. One of the hallmarks of NAFLD, hepatic steatosis, is a common feature in canine congenital portosystemic shunts. The aim of this study was to gain detailed insight into the pathogenesis of steatosis in this large animal model. Hepatic lipid accumulation, gene-expression analysis and HPLC-MS of neutral lipids and phospholipids in extrahepatic (EHPSS) and intrahepatic portosystemic shunts (IHPSS) was compared to healthy control dogs. Liver organoids of diseased dogs and healthy control dogs were incubated with palmitic- and oleic-acid, and lipid accumulation was quantified using LD540. In histological slides of shunt livers, a 12-fold increase of lipid content was detected compared to the control dogs (EHPSS Plipid-related genes to steatosis in portosystemic shunting was corroborated using gene-expression profiling. Lipid analysis demonstrated different triglyceride composition and a shift towards short chain and omega-3 fatty acids in shunt versus healthy dogs, with no difference in lipid species composition between shunt types. All organoids showed a similar increase in triacylglycerols after free fatty acids enrichment. This study demonstrates that steatosis is probably secondary to canine portosystemic shunts. Unravelling the pathogenesis of this hepatic steatosis might contribute to a better understanding of steatosis in NAFLD.

  7. Intrahepatic porto-hepatic venous shunts in Rendu-Osler-Weber disease: imaging demonstration

    International Nuclear Information System (INIS)

    Matsumoto, Shunro; Mori, Hiromu; Yamada, Yasunari; Hayashida, Tomoko; Hori, Yuzo; Kiyosue, Hiro

    2004-01-01

    This study describes the imaging features of the intrahepatic portohepatic venous (PHV) shunt, which is a potential cause of portosystemic encephalopathy in Rendu-Osler-Weber disease. Six patients with Rendu-Osler-Weber disease (two men, four women; age range 42-73 years) were retrospectively studied. There were two from one family and three from another family. Of these patients, one was diagnosed with definitive portosystemic encephalopathy because of a psychiatric disorder. We retrospectively reviewed the radiological examinations, including abdominal angiography (n=6), three-phase dynamic helical computed tomography (CT; n=3), and conventional enhanced CT (n=1). In one patient, CT during angiography and CT angioportography were also performed. Evaluation was placed on the imaging features of intrahepatic PHV shunts. On angiography, intrahepatic PHV shunts showing multiple and small shunts <5 mm in diameter in an apparent network were detected in all patents. In two patients, a large shunt with a size of either 7 or 10 mm was associated. These intrahepatic PHV shunts were predominantly distributed in the peripheral parenchyma. Intrahepatic PHV shunts would be characterized by small and multiple shunts in an apparent network on the periphery with or without a large shunt. (orig.)

  8. Calibration of piezoelectric RL shunts with explicit residual mode correction

    DEFF Research Database (Denmark)

    Høgsberg, Jan Becker; Krenk, Steen

    2017-01-01

    Piezoelectric RL (resistive-inductive) shunts are passive resonant devices used for damping of dominant vibration modes of a flexible structure and their efficiency relies on the precise calibration of the shunt components. In the present paper improved calibration accuracy is attained by an exte......Piezoelectric RL (resistive-inductive) shunts are passive resonant devices used for damping of dominant vibration modes of a flexible structure and their efficiency relies on the precise calibration of the shunt components. In the present paper improved calibration accuracy is attained...... by an extension of the local piezoelectric transducer displacement by two additional terms, representing the flexibility and inertia contributions from the residual vibration modes not directly addressed by the shunt damping. This results in an augmented dynamic model for the targeted resonant vibration mode...

  9. Fuzzy Inference System Approach for Locating Series, Shunt, and Simultaneous Series-Shunt Faults in Double Circuit Transmission Lines.

    Science.gov (United States)

    Swetapadma, Aleena; Yadav, Anamika

    2015-01-01

    Many schemes are reported for shunt fault location estimation, but fault location estimation of series or open conductor faults has not been dealt with so far. The existing numerical relays only detect the open conductor (series) fault and give the indication of the faulty phase(s), but they are unable to locate the series fault. The repair crew needs to patrol the complete line to find the location of series fault. In this paper fuzzy based fault detection/classification and location schemes in time domain are proposed for both series faults, shunt faults, and simultaneous series and shunt faults. The fault simulation studies and fault location algorithm have been developed using Matlab/Simulink. Synchronized phasors of voltage and current signals of both the ends of the line have been used as input to the proposed fuzzy based fault location scheme. Percentage of error in location of series fault is within 1% and shunt fault is 5% for all the tested fault cases. Validation of percentage of error in location estimation is done using Chi square test with both 1% and 5% level of significance.

  10. An unusual case of intrahepatic portosystemic venous shunt

    African Journals Online (AJOL)

    vena cava (IVC) (most common). Intrahepatic portosystemic venous shunts are rare vascular anomalies that may be detected in asymptomatic patients, given the recent advances in radiological imaging techniques. Accurate shunt evaluation and classification can be performed with ultrasound and multi-detector computed.

  11. A comparison of micropore membrane inlet mass spectrometry-derived pulmonary shunt measurement with Riley shunt in a porcine model.

    Science.gov (United States)

    Duenges, Bastian; Vogt, Andreas; Bodenstein, Marc; Wang, Hemei; Böhme, Stefan; Röhrig, Bernd; Baumgardner, James E; Markstaller, Klaus

    2009-12-01

    The multiple inert gas elimination technique was developed to measure shunt and the ratio of alveolar ventilation to simultaneous alveolar capillary blood flow in any part of the lung (V(A)'/Q') distributions. Micropore membrane inlet mass spectrometry (MMIMS), instead of gas chromatography, has been introduced for inert gas measurement and shunt determination in a rabbit lung model. However, agreement with a frequently used and accepted method for quantifying deficits in arterial oxygenation has not been established. We compared MMIMS-derived shunt (M-S) as a fraction of total cardiac output (CO) with Riley shunt (R-S) derived from the R-S formula in a porcine lung injury model. To allow a broad variance of atelectasis and therefore shunt fraction, 8 sham animals did not receive lavage, and 8 animals were treated by lung lavages with 30 mL/kg warmed lactated Ringer's solution as follows: 2 animals were lavaged once, 5 animals twice, and 1 animal 3 times. Variables were recorded at baseline and twice after induction of lung injury (T1 and T2). Retention data of sulfur hexafluoride, krypton, desflurane, enflurane, diethyl ether, and acetone were analyzed by MMIMS, and M-S was derived using a known algorithm for the multiple inert gas elimination technique. Standard formulas were used for the calculation of R-S. Forty-four pairs of M-S and R-S were recorded. M-S ranged from 0.1% to 35.4% and R-S from 3.7% to 62.1%. M-S showed a correlation with R-S described by linear regression: M-S = -4.26 + 0.59 x R-S (r(2) = 0.83). M-S was on average lower than R-S (mean = -15.0% CO, sd = 6.5% CO, and median = -15.1), with lower and upper limits of agreement of -28.0% and -2.0%, respectively. The lower and upper limits of the 95% confidence intervals were -17.0 and -13.1 (P < 0.001, Student's t-test). Shunt derived from MMIMS inert gas retention data correlated well with R-S during breathing of oxygen. Shunt as derived by MMIMS was generally less than R-S.

  12. Carbohydrate metabolism in ripening banana and its alteration on gamma irradiation in relation to delay in ripening

    International Nuclear Information System (INIS)

    Surendranathan, K.K.; Nair, P.M.

    1980-01-01

    Ripening, of climacteric class of fruits like banana, is accompanied with an upsurge in respiration, indicating a change in metabolism from hexose monophosphate (HMP) shunt pathway to glycolytic pathway. The key enzyme in glycolytic pathway, namely, phosphofructokinase, is activated and this activation paralleled with the increase in respiration rate. The enhancement in the activity of enzymes of glycolytic and Kreb's cycle help the fruit to assimilate energy as ATP produced from the breakdown and oxidation of storage starch. The demand for energy supply is great for the different ripening processes. Gamma irradiation of the fruit at the preclimacteric stage delayed the onset of climacteric to about 7 to 8 days, thereby extending the ripening to 15-20 days. This delay was brought about by the alterations in the metabolism of carbohydrate. There is a predominance of HMP pathway in irradiated banana. This along with the activation of phosphatases like FDPase and F-6-Pase restricted the entrance of sugar phosphate esters to Kreb's cycle for oxidation. The functioning of Kreb's cycle is also affected by the inhibition of succinic dehydrogenase. But activation of glyoxylate shunt pathway helped to maintain the levels of Kreb's cycle intermediates, like citrate and malate, although energy production is reduced. Finally the activation of gluconeogenic pathway helps in channelling the metabolites back to sugars. All these metabolic changes cause a considerable depletion in the production of ATP. (auth.)

  13. Shunt occlusion for portosystemic shunt syndrome related refractory hepatic encephalopathy-A single-center experience in 21 patients from Kerala.

    Science.gov (United States)

    Philips, Cyriac Abby; Kumar, Lijesh; Augustine, Philip

    2017-09-01

    Large spontaneous portosystemic shunts (SPSS) are seen in a subset of patients with liver disease and medically refractory recurrent/persistent hepatic encephalopathy (MRHE). Shunt occlusion has been shown to improve clinical outcomes. We retrospectively analyzed patient characteristics, SPSS attributes, procedural features, baseline clinical and investigational parameters, neurological outcomes, adverse effects (procedure and portal hypertension related), and risk factors predicting outcomes in liver disease patients undergoing shunt occlusion procedure for MRHE. Between October 2016 and July 2017, 21 patients (Child-Pugh score, CTP 6 to 13) with mean model of end-stage liver disease (MELD) and MELD-sodium scores 15.7 and 19.3 respectively with MRHE [3-cirrhotic Parkinsonism (CP)] were diagnosed to have single or multiple large SPSSs. A total of 29 shunts were occluded (1 surgical, 20 non-surgical). Recurrent and persistent HE and CP markedly improved in the short (n=20, 1 to 3 months), intermediate (n=12, 3 to 6 months), and long (n=7, 6 to 9 months) follow up. None had spontaneous or persistent HE at a median follow up 105 (30 to 329) days (p11 predicted mortality post shunt occlusion (p=0.04). Embolization of large SPSS in liver disease patients with MRHE and modestly preserved liver function is safe and efficacious and associated with improved quality of life and can function as a bridge to liver transplantation in accurately selected patients.

  14. Uterine perforation by a cystoperitoneal shunt, an unusual cause of recurrent vaginal discharge.

    Science.gov (United States)

    Poilblanc, Mathieu; Sentilhes, Loïc; Mercier, Philippe; Lefèbvre, Céline; Descamps, Philippe

    2012-01-01

    We describe the first reported case of uterine perforation by a cystoperitoneal shunt. The mechanism of this unusual complication is unclear. A 17-year-old patient had a cystoperitoneal shunt for a porencephalic cyst. She presented with recurrent watery vaginal discharge. A pelvic ultrasound examination showed that the uterus had been perforated by the distal tip of the shunt. The cystoperitoneal shunt was converted to a ventriculo-atrial shunt, and the vaginal discharge subsequently resolved. The appearance of light and clear vaginal discharge in a patient with a cystoperitoneal shunt raises the possibility of uterine perforation. This can be confirmed by ultrasound and analysis of the discharge. Removal of the shunt leads to spontaneous closure of the uterine defect.

  15. Aberrant hepatic lipid storage and metabolism in canine portosystemic shunts.

    Directory of Open Access Journals (Sweden)

    Lindsay Van den Bossche

    Full Text Available Non-alcoholic fatty liver disease (NAFLD is a poorly understood multifactorial pandemic disorder. One of the hallmarks of NAFLD, hepatic steatosis, is a common feature in canine congenital portosystemic shunts. The aim of this study was to gain detailed insight into the pathogenesis of steatosis in this large animal model. Hepatic lipid accumulation, gene-expression analysis and HPLC-MS of neutral lipids and phospholipids in extrahepatic (EHPSS and intrahepatic portosystemic shunts (IHPSS was compared to healthy control dogs. Liver organoids of diseased dogs and healthy control dogs were incubated with palmitic- and oleic-acid, and lipid accumulation was quantified using LD540. In histological slides of shunt livers, a 12-fold increase of lipid content was detected compared to the control dogs (EHPSS P<0.01; IHPSS P = 0.042. Involvement of lipid-related genes to steatosis in portosystemic shunting was corroborated using gene-expression profiling. Lipid analysis demonstrated different triglyceride composition and a shift towards short chain and omega-3 fatty acids in shunt versus healthy dogs, with no difference in lipid species composition between shunt types. All organoids showed a similar increase in triacylglycerols after free fatty acids enrichment. This study demonstrates that steatosis is probably secondary to canine portosystemic shunts. Unravelling the pathogenesis of this hepatic steatosis might contribute to a better understanding of steatosis in NAFLD.

  16. The use of abdominal binders to treat over-shunting headaches.

    Science.gov (United States)

    Sklar, Frederick H; Nagy, Laszlo; Robertson, Brian D

    2012-06-01

    Headaches are common in children with shunts. Headaches associated with over-shunting are typically intermittent and tend to occur later in the day. Lying down frequently makes the headaches better. This paper examines the efficacy of using abdominal binders to treat over-shunting headaches. Over an 18-year period, the senior author monitored 1027 children with shunts. Office charts of 483 active patients were retrospectively reviewed to identify those children with headaches and, in particular, those children who were thought to have headaches as a result of over-shunting. Abdominal binders were frequently used to treat children with presumed over-shunting headaches, and these data were analyzed. Of the 483 patients undergoing chart review, 258 (53.4%) had headache. A clinical diagnosis of over-shunting was made in 103 patients (21.3% overall; 39.9% of patients with headache). In 14 patients, the headaches were very mild (1-2 on a 5-point scale) and infrequent (1 or 2 per month), and treatment with an abdominal binder was not thought indicated. Eighty-nine patients were treated with a binder, but 19 were excluded from this retrospective study for noncompliance, interruption of the binder trial, or lack of follow-up. The remaining 70 pediatric patients, who were diagnosed with over-shunting headaches and were treated with abdominal binders, were the subjects of a more detailed retrospective study. Significant headache improvement was observed in 85.8% of patients. On average, the patients wore the binders for approximately 1 month, and headache relief usually persisted even after the binders were discontinued. However, the headaches eventually did recur in many of the patients more than a year later. In these patients, reuse of the abdominal binder was successful in relieving headaches in 78.9%. The abdominal binder is an effective, noninvasive therapy to control over-shunting headaches in most children. This treatment should be tried before any surgery is

  17. Posthemorrhagic Hydrocephalus in Newborns: Clinical Characteristics and Role of Ventriculoperitoneal Shunts

    Directory of Open Access Journals (Sweden)

    Inn-Chi Lee

    2009-02-01

    Conclusion: Patients who were shunt-dependent had worse neurodevelopmental outcomes and greater mortality than those without shunts. The results appeared to depend on how far the hydrocephalus had progressed and on the degree of IVH, but the necessity of VP shunts requires reevaluation before they are implanted.

  18. Gravitational shunt units may cause under-drainage in bedridden patients.

    Science.gov (United States)

    Kaestner, S; Kruschat, T; Nitzsche, N; Deinsberger, W

    2009-03-01

    Implantation of a shunt in a hydrocephalic patient still carries a risk of complications such as over-drainage and under-drainage. Gravitational shunt units are especially designed to minimize the problem of over-drainage. Nevertheless, these valves carry a risk of under-drainage. The best choice of valve for a patient is still challenging. The purpose of this survey was to identify in which patients a gravitational shunt valve is liable to lead to under-drainage. Patients with hydrocephalus entered prospectively into a data base were reviewed retrospectively. The patients were treated between January 2006 to the end of Feb 2007 and those experiencing under- or over-drainage were identified. Thirty-five ventriculo-peritoneal shunt systems were implanted in adult patients. The cause of the hydrocephalus was: normal pressure hydrocephalus in 18 patients, post-haemorrhagic following subarachnoid or intracerebral haemorrhage in 11, associated with a tumour in four and followed a head injury in two patients. Three different valves were used: an adjustable shunt valve with gravitational unit (Pro-GAV 0-20/25 in 21 patients), a gravitational shunt valve with fixed opening pressure (GAV 5/30 in nine patients) and an adjustable differential valve (Hakim medos in five patients). Four patients developed severe, valve-related under-drainage. Each had received a gravitational shunt valve and all were bedridden. In two of these patients it was necessary to change the valve. One patient who had received a differential valve, after regaining mobility developed severe over-drainage with bilateral subdural haematomas. Over-drainage was not seen in long-term bedridden patients with a differential shunt valve. If a bedridden patient with a gravitational shunt valve system lies with a slightly elevated head, this leads to activation of the gravitational unit and this may cause under drainage. As a result, we advise not using an anti-siphon devices in a patient who is bedridden for a

  19. Valved or valveless ventriculoperitoneal shunting in the treatment of post-haemorrhagic hydrocephalus

    DEFF Research Database (Denmark)

    Andreasen, Trine Hjorslev; Holst, Anders Vedel; Lilja, Alexander

    2016-01-01

    BACKGROUND: Implant infection and obstruction are major complications for ventriculoperitoneal shunts in patients with post-haemorrhagic hydrocephalus. In an effort to (1) reduce the incidence of these complications, (2) reduce the rate of shunt failure and (3) shorten the duration of neurosurgical...... hospitalisation, we have implemented valveless ventriculoperitoneal shunts at our department for adult patients with post-haemorrhagic hydrocephalus and haemorrhagic cerebrospinal fluid at the time of shunt insertion. METHODS: All adult patients (>18 years old) treated for post-haemorrhagic hydrocephalus.......3 %, p = 0.02), but a higher rate of overdrainage (10.3 % vs 2.6 %, p = 0.04). CONCLUSION: The use of a valveless shunting for patients with post-haemorrhagic hydrocephalus results in shorter duration of neurosurgical hospitalisation and lower rate of shunt infection, although these advantages should...

  20. Clinical outcomes of temporary shunting for infants with cerebral pseudomeningocele.

    Science.gov (United States)

    Mattei, Tobias A; Sambhara, Deepak; Bond, Brandon J; Lin, Julian

    2014-02-01

    Although in the case of subdural collections temporary shunting has been suggested as a viable alternative for definitive drainage of the accumulated fluid until restoration of the normal CSF dynamics, there is no agreement on the best management strategy for pseudomeningocele. The authors performed a retrospective chart review in order to evaluate the clinical outcomes of infants temporarily shunted for pseudomeningocele without encephalocele at our institution (The University of Illinois at Peoria/Illinois Neurological Institute) in the period from 2004 to 2012. The epidemiological characteristics, clinical management, and final outcomes of such subpopulation were compared with a control group which received temporary shunting for subdural hematomas (SDH) during the same period. Four patients (100% male) ranging in age from 8.9 to 27.1 months (mean = 13.88) with pseudomeningocele and 17 patients (64.7% male) ranging in age from 1.9 to 11.8 months (mean = 4.15) with SDH were identified. Although the initial management included sequential percutaneous subdural tapping in 82% of the patients, all children ultimately failed such strategy, requiring either subdural-peritoneal (81% of the cases) or subgaleal-peritoneal (19% of the cases) shunting. The mean implant duration was 201 days for the pseudomeningocele group and 384 days for the SDH one. Mean post-shunt hospitalization was 2 days for patients with pseudomeningocele and 4 days for patients with SDH. There was no statistical difference in terms of complications, length of hospitalization post-shunting, or clinical outcomes between the patients with pseudomeningocele and those with SDH. Temporary shunting of infants with pseudo-meningocele constitutes a viable therapeutic alternative with favorable clinical outcomes and a low risk of shunt dependency similar to those of children with SDH.

  1. Metabolic regulation at the tricarboxylic acid and glyoxylate cycles of the lignin-degrading basidiomycete Phanerochaete chrysosporium against exogenous addition of vanillin.

    Science.gov (United States)

    Shimizu, Motoyuki; Yuda, Naoki; Nakamura, Tomofumi; Tanaka, Hiroo; Wariishi, Hiroyuki

    2005-10-01

    A proteomic differential display technique was utilized to study cellular responses of Phanerochaete chrysosporium exposed to vanillin, one of the key intermediates found during lignin biodegradation. Intracellular proteins were resolved by 2-DE and target protein spots were identified using MALDI-MS after in-gel tryptic digestions. Upon addition of vanillin to P. chrysosporium, up-regulation of homogentisate 1,2-dioxygenase, 1,4-benzoquinone reductases, aldehyde dehydrogenase, and aryl-alcohol dehydrogenase, which seem to play roles in vanillin metabolism, was observed. Furthermore, enzymes involved in glycolysis, the tricarboxylic acid cycle, the pentose-phosphate cycle, and heme biosynthesis were also activated. Up-regulation of extracellular peroxidase was also observed. One of the most unique phenomena against exogenous vanillin was a switch from the glyoxylate cycle to the tricarboxylic acid cycle, where a drastic increase in isocitrate dehydrogenase activity was observed. The exogenous addition of other aromatic compounds also caused an increase in its activity, which in turn triggered NAD(P)H production via the action of dehydrogenases in the tricarboxylic acid cycle, heme biosynthesis via the action of aminolevulinic acid synthase on succinyl-CoA, and energy production via activation of the mitochondrial electron transfer system. These metabolic shifts seem to be required for activating a metabolic system for aromatic compounds.

  2. Scoliosis and Syringomyelia With Chiari Malformation After Lumbar Shunting

    Directory of Open Access Journals (Sweden)

    Hsin-Hung Chen

    2010-07-01

    Full Text Available Unsteady gait was noted in a 2-year-old boy with a lumboperitoneal (LP shunt that had been inserted 1 year earlier for increased head circumference caused by communicating hydrocephalus. Scoliosis was also noted during postoperative follow-up. Magnetic resonance imaging revealed new hindbrain tonsillar herniation and an extensive syrinx from C3 to L1. The malfunctioning LP shunt was removed and posterior fossa decompression with ventriculoperitoneal shunt insertion was performed. The unsteady gait recovered completely and scoliosis improved. Magnetic resonance imaging demonstrated resolution of the syrinx and tonsillar herniation. Acquired Chiari I malformation after LP shunt is well documented; usually, patients have no symptoms. This is the first report to have all the cause and effect mechanisms among syringomyelia, scoliosis and Chiari I malformation in 1 patient. We review the literature and discuss the possible mechanisms.

  3. Epidural haematoma: pathophysiological significance of extravasation and arteriovenous shunting

    International Nuclear Information System (INIS)

    Habash, A.H.; Sortland, O.; Zwetnow, N.N.

    1982-01-01

    35 patients with epidural bleeding operated on at Rikshospitalet, Oslo, during the period 1965 - 1980 had preoperative angiography with visualization of the external carotid artery. Twenty-one patients had extravasation of contrast medium from meningeal arteries. Seventeen of the 21 had also shunting of contrast medium from meningeal arteries to meningeal or diploic veins, while 20 of the 21 also had bled from a ruptured meningeal artery at operation. It was further found that of 20 patients who deteriorated after trauma 18 had an epidural arteriovenous shunt or extravasation. Conversely, of 15 patients who improved after trauma 12 had no evidence of a shunt. The strong correlation between the clinical course and the occurrence of extravasation supports previous experimental and clinical data, indicating the epidural arteriovenous shunt to be a major factor in the pathophysiology and the outcome of epidural bleeding. (author)

  4. Assessment of surgical portosystemic shunts and associated complications: The diagnostic and therapeutic role of radiologists

    Energy Technology Data Exchange (ETDEWEB)

    Taslakian, Bedros, E-mail: btaslakian@gmail.com [Department of Radiology, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); Faraj, Walid, E-mail: wf07@aub.edu.lb [Department of General Surgery, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); Khalife, Mohammad, E-mail: mk12@aub.edu.lb [Department of General Surgery, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); Al-Kutoubi, Aghiad, E-mail: mk00@aub.edu.lb [Department of Radiology, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); El-Merhi, Fadi, E-mail: fe19@aub.edu.lb [Department of Radiology, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); Saade, Charbel, E-mail: cs39@aub.edu.lb [Department of Radiology, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); Hallal, Ali, E-mail: ah05@aub.edu.lb [Department of General Surgery, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); Haydar, Ali, E-mail: ah24@aub.edu.lb [Department of Radiology, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon)

    2015-08-15

    Highlights: • Portal hypertension is the pathological increase in portal venous pressure. • Surgical portosystemic shunting is an accepted methods to decrease portal venous pressure. • Surgical portosystemic shunts are divided into selective and nonselective. • Shunt thrombosis is a serious complication, resulting in shunt dysfunction. • Imaging is essential in the assessment of the shunt function and anatomy. - Abstract: Surgical portosystemic shunting, the formation of a vascular connection between the portal and systemic venous circulation, has been used as a treatment to reduce portal venous pressure. Although the use of portosystemic shunt surgery in the management of portal hypertension has declined during the past decade in favour of alternative therapies, and subsequently surgeons and radiologists became less familiar with the procedure, it remains a well-established treatment. Knowledge of different types of surgical portosystemic shunts, their pathophysiology and complications will help radiologists improve communication with surgeons and enhance their understanding of the diagnostic and therapeutic role of radiology in the assessment and management of these shunts. Optimal assessment of the shunt is essential to determine its patency and allow timely intervention. Both non-invasive and invasive imaging modalities complement each other in the evaluation of surgical portosystemic shunts. Interventional radiology plays an important role in the management of complications, such as shunt thrombosis and stenosis. This article describes the various types of surgical portosystemic shunts, explains the anatomy and pathophysiology of these shunts, illustrates the pearls and pitfalls of different imaging modalities in the assessment of these shunts and demonstrates the role of radiologists in the interventional management of complications.

  5. Assessment of surgical portosystemic shunts and associated complications: The diagnostic and therapeutic role of radiologists

    International Nuclear Information System (INIS)

    Taslakian, Bedros; Faraj, Walid; Khalife, Mohammad; Al-Kutoubi, Aghiad; El-Merhi, Fadi; Saade, Charbel; Hallal, Ali; Haydar, Ali

    2015-01-01

    Highlights: • Portal hypertension is the pathological increase in portal venous pressure. • Surgical portosystemic shunting is an accepted methods to decrease portal venous pressure. • Surgical portosystemic shunts are divided into selective and nonselective. • Shunt thrombosis is a serious complication, resulting in shunt dysfunction. • Imaging is essential in the assessment of the shunt function and anatomy. - Abstract: Surgical portosystemic shunting, the formation of a vascular connection between the portal and systemic venous circulation, has been used as a treatment to reduce portal venous pressure. Although the use of portosystemic shunt surgery in the management of portal hypertension has declined during the past decade in favour of alternative therapies, and subsequently surgeons and radiologists became less familiar with the procedure, it remains a well-established treatment. Knowledge of different types of surgical portosystemic shunts, their pathophysiology and complications will help radiologists improve communication with surgeons and enhance their understanding of the diagnostic and therapeutic role of radiology in the assessment and management of these shunts. Optimal assessment of the shunt is essential to determine its patency and allow timely intervention. Both non-invasive and invasive imaging modalities complement each other in the evaluation of surgical portosystemic shunts. Interventional radiology plays an important role in the management of complications, such as shunt thrombosis and stenosis. This article describes the various types of surgical portosystemic shunts, explains the anatomy and pathophysiology of these shunts, illustrates the pearls and pitfalls of different imaging modalities in the assessment of these shunts and demonstrates the role of radiologists in the interventional management of complications

  6. Small-Diameter PTFE Portosystemic Shunts: Portocaval vs Mesocaval

    Directory of Open Access Journals (Sweden)

    Robert Shields

    1998-01-01

    Full Text Available Fifty-seven patients with failed sclerotherapy received a mesocaval interposition shunt with an externally supported, ringed polytetrafluoroethylene prosthesis of either 10 or 12 mm diameter. Thirty-one patients had Child-Pugh gradeA disease and 26 grade B; all had a liver volume of 1000– 2500 ml. Follow-up ranged from 16 months to 6 years 3 months. Three patients (5 per cent died in the postoperative period. There were two postoperative recurrences of variceal haemorrhage and one recurrent bleed in the second year after surgery. The cumulative shunt patency rate was 95 per cent and the incidence of encephalopathy 9 per cent; the latter was successfully managed by protein restriction and/or lactulose therapy. The actuarial survival rate for the whole group at 6 years was 78 per cent, for those with Child-Pugh grade A 88 per cent and for grade B 67 per cent. Small-lumen mesocaval interposition shunting achieves portal decompression, preserves hepatopetal flow, has a low incidence of shunt thrombosis, prevents recurrent variceal bleeding and is not associated with significant postoperative encephalopathy.

  7. Shunt impedance of spiral loaded resonant rf cavities

    International Nuclear Information System (INIS)

    Peebles, P.Z. Jr.; Parvarandeh, M.

    1975-01-01

    Based upon a treatment of the spiral loaded resonant radio frequency cavity as a shorted quarter-wave transmission line, a model for shunt impedance is developed. The model is applicable to loosely wound spirals in large diameter containers. Theoretical shunt impedance is given for spirals wound from tubing of circular or rectangular cross section. The former produces higher shunt impedance. Measurements made at Oak Ridge National Laboratory on 17 copper cavities are described which support the theoretical results. Theoretical results are also compared to data from twenty-three additional cavities measured at Los Alamos Scientific Laboratory. It is shown that the theoretical function forms a useful means of interpreting the quality of constructed cavities. (author)

  8. Embolization of portal-systemic shunts in cirrhotic patients with chronic recurrent hepatic encephalopathy

    International Nuclear Information System (INIS)

    Sakurabayashi, Shin; Sezai, Shuichi; Yamamoto, Yoshihiro; Hirano, Masanori; Oka, Hiroshi

    1997-01-01

    Purpose. To evaluate the efficacy of embolization of portal-systemic shunts in cirrhotic patients with chronic recurrent hepatic encephalopathy (CRHE). Methods. Seven cirrhotic patients with CRHE refractory to medical treatment (3 men and 4 women, mean age 66 years) were studied. Five patients had splenorenal shunts, 1 had a gastrorenal shunt, and 1 had an intrahepatic portal vein-hepatic vein shunt. Shunt embolization was performed using stainless steel coils, with a percutaneous transhepatic portal vein approach in 4 patients and a transrenal vein approach in 3 patients. Results. After embolization, the shunt disappeared in 4 patients on either ultrasound pulsed Doppler monitoring or portography. Complications observed in the 7 patients were fever, transient pleural effusion, ascites, and mild esophageal varices. For 3-6 months after embolization, the 4 patients whose shunts disappeared showed minimal or no reappearance of a shunt, and had no recurrence of encephalopathy. The serum ammonia levels decreased and electroencephalograms also improved. One of the 4 patients, who developed mild esophageal varices, required no treatment. Treatment was effective in 3 of the 4 patients (75%) who underwent embolization via a transhepatic portal vein. Conclusion. Transvascular embolization of shunts improved the outcome in 4 of 7 patients. The most effective embolization was achieved via the percutaneous transhepatic portal vein approach

  9. Transdiaphragmatic Approach to Attenuate Porto-Azygos Shunts Inserting in the Thorax.

    Science.gov (United States)

    Or, Matan; Kitshoff, Adriaan; Devriendt, Nausikaa; De Ridder, Marianne; Quist-Rybachuk, Galena; de Rooster, Hilde

    2016-11-01

    To describe the surgical technique and document the application of a transdiaphragmatic approach to attenuate porto-azygos shunts inserting in the thoracic section of the azygos vein. Cadaveric study and prospective case series. Canine cadavers (n=6) and client-owned dogs with porto-azygos shunts inserting in the thoracic section of the azygos vein (n=9). In the cadavers, the azygos vein was filled with aqueous latex. Landmarks were established for creating a safe transdiaphragmatic approach to the caudal intrathoracic portion of the azygos vein. In the clinical cases, porto-azygos communication was diagnosed by trans-splenic portal scintigraphy. All shunts were attenuated close to their insertion site via ventral midline celiotomy and a transdiaphragmatic approach to the shunt. Perioperative complications were recorded. A 3-5 cm incision, 0.5-1 cm ventral and lateral to the level of the aortic hiatus, was made in the pars lumbalis part of the diaphragm. Stay sutures at both sides of the diaphragmatic incision were placed to open up the incision and a retractor was used to push the esophagus away from the aorta. Intrathoracic insertion of the shunt was confirmed intraoperative. Exposure of the shunt insertion site at the azygos vein was excellent in all clinical cases. No intraoperative or postoperative complications were encountered. If thoracic attenuation of a porto-azygos shunt is considered, a transdiaphragmatic approach exposes the insertion site for shunt attenuation. This approach is straightforward, without unnecessary abdominal organ manipulation, and since attenuates at the insertion, avoids missing additional contributing branches. © Copyright 2016 by The American College of Veterinary Surgeons.

  10. High-Flow Arterio-Hepatic Venous Shunt in Hepatocellular Carcinoma: Use of Multi-Electrode Radiofrequency for Shunt Obliteration

    Energy Technology Data Exchange (ETDEWEB)

    Pua, Uei, E-mail: druei@yahoo.com [Tan Tock Seng Hospital, Department of Diagnostic Radiology (Singapore)

    2015-10-15

    Intra-tumoral arterio-hepatic venous shunting (AHVS) poses an impediment to transarterial chemoembolization of liver tumors. Not only does it present a potential hazard for systemic shunting and embolization, but also the altered flow dynamics may also result in poor delivery of drug/embolics to the target tumor bed. Current available techniques to overcome AVHS include arterial embolization (particles, coils, glue, etc.) or temporary venous occlusion using balloons. We hereby illustrate the use of radiofrequency ablation to obliterate a complex AHVS consisting of a varix-like venous aneurysm.

  11. Migration of the peritoneal catheter of a ventriculoperitoneal shunt ...

    African Journals Online (AJOL)

    Ventricular shunt is a well-established modality in the management of hydrocephalus. However, it can be associated with numerous complications and disastrous consequences. The reported incidence of intra-abdominal complications in infants and children after ventriculoperitoneal (VP) shunt procedures is about 24% ...

  12. Shunted Piezoelectric Vibration Damping Analysis Including Centrifugal Loading Effects

    Science.gov (United States)

    Min, James B.; Duffy, Kirsten P.; Provenza, Andrew J.

    2011-01-01

    Excessive vibration of turbomachinery blades causes high cycle fatigue problems which require damping treatments to mitigate vibration levels. One method is the use of piezoelectric materials as passive or active dampers. Based on the technical challenges and requirements learned from previous turbomachinery rotor blades research, an effort has been made to investigate the effectiveness of a shunted piezoelectric for the turbomachinery rotor blades vibration control, specifically for a condition with centrifugal rotation. While ample research has been performed on the use of a piezoelectric material with electric circuits to attempt to control the structural vibration damping, very little study has been done regarding rotational effects. The present study attempts to fill this void. Specifically, the objectives of this study are: (a) to create and analyze finite element models for harmonic forced response vibration analysis coupled with shunted piezoelectric circuits for engine blade operational conditions, (b) to validate the experimental test approaches with numerical results and vice versa, and (c) to establish a numerical modeling capability for vibration control using shunted piezoelectric circuits under rotation. Study has focused on a resonant damping control using shunted piezoelectric patches on plate specimens. Tests and analyses were performed for both non-spinning and spinning conditions. The finite element (FE) shunted piezoelectric circuit damping simulations were performed using the ANSYS Multiphysics code for the resistive and inductive circuit piezoelectric simulations of both conditions. The FE results showed a good correlation with experimental test results. Tests and analyses of shunted piezoelectric damping control, demonstrating with plate specimens, show a great potential to reduce blade vibrations under centrifugal loading.

  13. What is the risk of infecting a cerebrospinal fluid-diverting shunt with percutaneous tapping?

    Science.gov (United States)

    Spiegelman, Lindsey; Asija, Richa; Da Silva, Stephanie L; Krieger, Mark D; McComb, J Gordon

    2014-10-01

    Most CSF-diverting shunt systems have an access port that can be percutaneously tapped. Tapping the shunt can yield valuable information as to its function and whether an infection is present. The fear of causing a shunt infection by tapping may limit the physician's willingness to do so. The authors of this study investigate the risk of infecting a shunt secondary to percutaneous tapping. Following institutional review board approval, CSF specimens obtained from tapping an indwelling CSF-diverting shunt during the 2011 and 2012 calendar years were identified and matched with clinical information. A culture-positive CSF sample was defined as an infection. If results were equivocal, such as a broth-only-positive culture, a repeat CSF specimen was examined. The CSF was obtained by tapping the shunt access port with a 25-gauge butterfly needle after prepping the unshaven skin with chlorhexidine. During the study period, 266 children underwent 542 shunt taps. With 541 taps, no clinical evidence of a subsequent shunt infection was found. One child's CSF went from sterile to infected 11 days later; however, this patient had redness along the shunt tract at the time of the initial sterile tap. The risk of infection from tapping a shunt is remote if the procedure is done correctly.

  14. Numerical and experimental studies of stack shunt current for vanadium redox flow battery

    International Nuclear Information System (INIS)

    Yin, Cong; Guo, Shaoyun; Fang, Honglin; Liu, Jiayi; Li, Yang; Tang, Hao

    2015-01-01

    Highlights: • A coupled three-dimensional model of VRB cell stack is developed. • Shunt current of the stack is studied with the model and experiment. • Increased electrolyte resistance in channel and manifold lowers the shunt current. • Shunt current loss increases with stack cell number nonlinearly. - Abstract: The stack shunt current of VRB (vanadium redox flow battery) was investigated with experiments and 3D (three-dimensional) simulations. In the proposed model, cell voltages and electrolyte conductivities were calculated based on electrochemical reaction distributions and SOC (state of charge) values, respectively, while coulombic loss was estimated according to shunt current and vanadium ionic crossover through membrane. Shunt current distributions and coulombic efficiency are analyzed in terms of electrolyte conductivities and stack cell numbers. The distributions of cell voltages and shunt currents calculated with proposed model are validated with single cell and short stack tests. The model can be used to optimize VRB stack manifold and channel designs to improve VRB system efficiency

  15. Prophylactic antibiotics in pediatric shunt surgery.

    Science.gov (United States)

    Biyani, N; Grisaru-Soen, G; Steinbok, P; Sgouros, S; Constantini, S

    2006-11-01

    The optimal antibiotic prophylaxis for pediatric shunt-related procedures is not clear. There is much inconsistency among different medical centers. This paper summarizes and analyzes the various prophylactic antibiotic regiments used for shunt-related surgeries at different pediatric neurosurgery centers in the world. A survey questionnaire was distributed through the Pediatric Neurosurgery list-server (an e-mail-based special interest group in pediatric neurosurgery). Forty-five completed questionnaires were received, one per medical center, primarily from pediatric neurosurgeons with the following geographic breakdown: 25 from North America, 13 from Europe, and 7 from Asia and other countries. All centers routinely administered prophylactic antibiotics for shunt-related procedures. The drugs of choice were first-generation cephalosporins (23), second-generation cephalosporins (10), naficillin/oxacillin (4), vancomycin (3), clindamycin (1), amoxicillin (1), and mixed protocols in three centers. The initial drug administration ("first dose") was: in the department before transfer to operating room (5), upon arrival to operating room (11), at induction of anesthesia (13), and at initial skin incision (16). The duration of antibiotic dosage also varied: single dose (13), 24-h administration (26), 48-h administration (2), and longer than 48 h in four centers. Two general tendencies were noted, common to the majority of participating centers. There was a general trend to modify antibiotic treatment protocol in "high-risk" populations. The second common theme noted in more than half of responding centers was the use of long-term antibiotic treatment for externalized devices (such as externalized shunts, external ventricular drains or lumbar drains), usually till the device was in place.

  16. Multi-resonant electromagnetic shunt in base isolation for vibration damping and energy harvesting

    Science.gov (United States)

    Pei, Yalu; Liu, Yilun; Zuo, Lei

    2018-06-01

    This paper investigates multi-resonant electromagnetic shunts applied to base isolation for dual-function vibration damping and energy harvesting. Two multi-mode shunt circuit configurations, namely parallel and series, are proposed and optimized based on the H2 criteria. The root-mean-square (RMS) value of the relative displacement between the base and the primary structure is minimized. Practically, this will improve the safety of base-isolated buildings subjected the broad bandwidth ground acceleration. Case studies of a base-isolated building are conducted in both the frequency and time domains to investigate the effectiveness of multi-resonant electromagnetic shunts under recorded earthquake signals. It shows that both multi-mode shunt circuits outperform traditional single mode shunt circuits by suppressing the first and the second vibration modes simultaneously. Moreover, for the same stiffness ratio, the parallel shunt circuit is more effective at harvesting energy and suppressing vibration, and can more robustly handle parameter mistuning than the series shunt circuit. Furthermore, this paper discusses experimental validation of the effectiveness of multi-resonant electromagnetic shunts for vibration damping and energy harvesting on a scaled-down base isolation system.

  17. Demonstration of arterioportal shunt by dynamic computed tomography and its diagnostic value

    International Nuclear Information System (INIS)

    Nakayama, Takatsune; Hiyama, Yoshiaki; Saitoh, Masayuki

    1983-01-01

    Sixty-one patients, 41 with hepatocellular carcinoma and 20 with liver cirrhosis, were examined by dynamic computed tomography (CT) and all but one with hepatocellular carcinoma were examined by celiac angiography. Dynamic CT disclosed arterioportal shunting in eleven cases of hepatocellular carcinima and in one of cirrhotics. All of them were confirmed by angiography except one case in which angiography could not be performed. In ten of these eleven cases arterioportal shunt was adjacent to a mass lesion on dynamic CT, suggesting tumor invasion into the portal branch. In one with hepatocellular carcinoma, the shunt was remote from the mass. In one with cirrhosis, there was no mass. In these last two cases, the shunt might have been caused by prior percutaneus needle puncture. In another case of hepatocellular carcinoma, celiac angiography but not CT demonstrated an arterioportal shunt. Thus dynamic CT was nearly as diagnostic as celiac arterigraphy for the demonstration of arterioportal shunt due to portal invasion of hepatocellular carcinoma and percutaneus needle puncture. (author)

  18. Demonstration of arterioportal shunt by dynamic computed tomography and its diagnostic value

    Energy Technology Data Exchange (ETDEWEB)

    Nakayama, Takatsune; Hiyama, Yoshiaki; Saitoh, Masayuki

    1983-11-01

    Sixty-one patients, 41 with hepatocellular carcinoma and 20 with liver cirrhosis, were examined by dynamic computed tomography (CT) and all but one with hepatocellular carcinoma were examined by celiac angiography. Dynamic CT disclosed arterioportal shunting in eleven cases of hepatocellular carcinoma and in one of cirrhotics. All of them were confirmed by angiography except one case in which angiography could not be performed. In ten of these eleven cases arterooportal shunt was adjacent to a mass lesion on dynamic CT, suggesting tumor invasion into the portal branch. In one with hepatocellular carcinoma, the shunt was remote from the mass. In one with cirrhosis, there was no mass. In these last two cases, the shunt might have been caused by prior percutaneus needle puncture. In another case of hepatocellular carcinoma, celiac angiography but not CT demonstrated an arterioportal shunt. Thus dynamic CT was nearly as diagnostic as celiac arterigraphy for the demonstration of arterioportal shunt due to portal invasion of hepatocellular carcinoma and percutaneus needle puncture.

  19. Splenophrenic portosystemic shunt in dogs with and without portal ...

    African Journals Online (AJOL)

    The possible existence of the same pattern of porto-caval connection in dogs having a single congenital portosystemic shunt (CPSS) and in dogs having multiple acquired portosystemic shunt (MAPSS) secondary to portal hypertension (PH) was evaluated. Retrospective evaluation of all CT examinations of patients having ...

  20. Electron microscopic evaluation of a gold glaucoma micro shunt after explantation.

    Science.gov (United States)

    Berk, Thomas A; Tam, Diamond Y; Werner, Liliana; Mamalis, Nick; Ahmed, Iqbal Ike K

    2015-03-01

    We present a case of an explanted gold glaucoma micro shunt (GMS Plus) and the subsequent light and electron microscopic analyses. The shunt was implanted in a patient with medically refractive glaucoma. The intraocular pressure (IOP) was stable at 12 mm Hg 6 months postoperatively but spiked to 26 mm Hg 6 months later; membranous growth was visible on the implant gonioscopically. A second gold micro shunt was placed 2 years after the first. The IOP was 7 mm Hg 1 week postoperatively but increased to 23 mm Hg 3 weeks later; similar membranous growth was visible on this implant. One of the shunts was explanted, and light and scanning electron microscopic analyses revealed encapsulation around the shunt exterior and connective tissue invasion of the microstructure. This represents the first electron microscopic analysis of an explanted gold glaucoma micro shunt and the first unequivocal images of the fibrotic pseudo-capsule traversing its microchannels and fenestrations. Dr. Ahmed is a consultant to and has received research grants from Solx, Inc. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  1. Symptomatic spinal cord deformity secondary to a redundant intramedullary shunt catheter

    International Nuclear Information System (INIS)

    Quencer, R.M.; Montalvo Morse, B.M.; Green, B.A.; Eismont, F.J.

    1985-01-01

    Right arm pain, motor and sensory loss in the right arm and right facial numbness recurred in a 27 year old quadraplegic shortly after a posttraumatic spinal cord cyst (PTSCC) was shunted via a catheter into the adjacent subarachnoid space. Although shunt malfunction was clinically suspected, metrizamide computed tomography (MCT) suggested that redundancy of the catheter had caused deformity of the spinal cord. This hypothesis was confirmed at surgery when intraoperative spinal sonography (IOSS) showed that the spinal cord deformity at C 1 -C 2 disappeared when the catheter was withdrawn. This case shows that new or recurrent spinal cord symptoms may be due to a mechanical deformity of the cord rather than shunt malfunction, that restricting the length of the shunt catheter which is used to decompress PTSCCs is important, and that IOSS is an indispensible tool for visualizing the changes in spinal cord morphology during shunting procedures. (orig.)

  2. Intrahepatic portal-hepatic venous shunt diagnosed by ultrasonography and computed tomography

    International Nuclear Information System (INIS)

    Shinagawa, Takashi; Iino, Yasuo; Ukaji, Haruyasu; Ishizuka, Masaharu

    1986-01-01

    Two cases of intrahepatic portal-hepatic venous shunt found by ultrasonography and computed tomography are reported. The first case came to the hospital because of hematuria. A large shunt between the portal vein and the hepatic vein was demonstrated by ultrasonography done for screening, and confirmed by percutaneous transhepatic portography (PTP). The second case was admitted because of cholelithiasis. Computed tomography with contrast enhancement revealed a dilated portal vein in the upper portion of the right lobe. It was subsequently shown by PTP to be a portal-hepatic venous shunt. Portal vein pressure and histological finding of the liver were normal in both cases. The etiology of the shunt was thought to be congenital in these cases for lack of liver disease, portal hypertension and history of trauma. Both cases had no history of hepatic encephalopathy and did not show any symptom attributable to the shunt. (author)

  3. A new method for the measurement of intrahepatic shunts

    International Nuclear Information System (INIS)

    Hoefs, J.C.; Reynolds, T.B.; Pare, P.; Sakimura, I.

    1984-01-01

    After transhepatic portal pressure determination, 96 patients were assessed for the presence of intrahepatic shunts by injection of microspheres (25 +/- 5 micron diameter) into the portal vein using RISA-131I as an indicator of dilution. Multiple portal vein injections in each patient allowed blood sampling from the hepatic vein (site 1) and from two inferior vena cava sampling sites (site 2, at the junction of the hepatic vein orifice with the inferior vena cava, and site 3, 2 to 3 cm closer to or within the right atrium). Intrahepatic shunting was calculated from each site: hepatic vein in 57 patients and inferior vena cava, site 2 in 43 patients and site 3 in 77 patients. At least one valid IHS calculation was available in 92 of the patients. Intrahepatic shunting calculated from sequential portal vein injections with sampling from the hepatic vein was highly correlated (r . 0.98, p less than 0.0001, slope . 1.0), with a mean difference of 1.9% +/- 1.9%. There was no significant difference by t test comparison of the mean IHS calculated from sites 1, 2, and 3. Occasional marked discrepancies were noted between IHS calculated from site 1 or site 2 compared with site 3, and the site 3 calculation was always greater. A shunt index in all patients included shunts calculated from the hepatic vein in 57 patients plus shunt calculation from the inferior vena cava in the remaining patients (site 2 in 26 patients and site 3 in nine). The 82 patients with portal hypertension or chronic liver disease had a higher portal pressure, 13.8 +/- 4.6 mm Hg, and a significantly greater shunt index, 13.7% +/- 24.5% compared with controls. The frequency distribution of IHS in patients with chronic liver disease demonstrated less than 2% IHS in 49% of patients and less than 5% IHS in 63%. The validity of our methods and the implications of the infrequent demonstration of a large IHS are discussed

  4. Staged Transcatheter Treatment of Portal Hypoplasia and Congenital Portosystemic Shunts in Children

    Energy Technology Data Exchange (ETDEWEB)

    Bruckheimer, Elchanan, E-mail: elchananb@bezeqint.net; Dagan, Tamir [Schneider Children' s Medical Center Israel, Section of Pediatric Cardiology (Israel); Atar, Eli; Schwartz, Michael [Schneider Children' s Medical Center Israel, Section of Radiology (Israel); Kachko, Ludmila [Schneider Children' s Medical Center Israel, Section of Anesthesiology (Israel); Superina, Riccardo; Amir, Gabriel [Schneider Children' s Medical Center Israel, Section of Pediatric Cardiology (Israel); Shapiro, Rivka [Schneider Children' s Medical Center Israel, Section of Gastroenterology (Israel); Birk, Einat [Schneider Children' s Medical Center Israel, Section of Pediatric Cardiology (Israel)

    2013-12-15

    Purpose: Congenital portosystemic shunts (CPSS) with portal venous hypoplasia cause hyperammonemia. Acute shunt closure results in portal hypertension. A transcatheter method of staged shunt reduction to afford growth of portal vessels followed by shunt closure is reported. Methods: Pressure measurements and angiography in the CPSS or superior mesenteric artery (SMA) during temporary occlusion of the shunt were performed. If vessels were diminutive and the pressure was above 18 mmHg, a staged approach was performed, which included implantation of a tailored reducing stent to reduce shunt diameter by {approx}50 %. Recatheterization was performed approximately 3 months later. If the portal pressure was below 18 mmHg and vessels had developed, the shunt was closed with a device. Results: Six patients (5 boys, 1 girl) with a median age of 3.3 (range 0.5-13) years had CPSS portal venous hypoplasia and hyperammonemia. Five patients underwent staged closure. One patient tolerated acute closure. One patient required surgical shunt banding because a reducing stent could not be positioned. At median follow-up of 3.8 (range 2.2-8.4) years, a total of 21 procedures (20 transcatheter, 1 surgical) were performed. In all patients, the shunt was closed with a significant reduction in portal pressure (27.7 {+-} 11.3 to 10.8 {+-} 1.8 mmHg; p = 0.016), significant growth of the portal vessels (0.8 {+-} 0.5 to 4.0 {+-} 2.4 mm; p = 0.037), and normalization of ammonia levels (202.1 {+-} 53.6 to 65.7 {+-} 9.6 {mu}mol/L; p = 0.002) with no complications. Conclusion: Staged CPSS closure is effective in causing portal vessel growth and treating hyperammonemia.

  5. Determining the optimal portal blood volume in a shunt before surgery in extrahepatic portal hypertension

    Directory of Open Access Journals (Sweden)

    Yurchuk Vladimir A

    2016-04-01

    Full Text Available The aim of the study: To determine the necessary shunt diameter and assess the optimal portal blood volume in a shunt in children with extrahepatic portal hypertension before the portosystemic shunt surgery. Changes in the liver hemodynamics were studied in 81 children aged from 4 to 7 years with extrahepatic portal hypertension. We established that it is necessary to calculate the shunt diameter and the blood volume in a shunt in patients with extrahepatic portal hypertension before the portosystemic shunt surgery. It allows us to preserve the hepatic portal blood flow and effectively decrease the pressure in the portal system. Portosystemic shunt surgery in patients with extrahepatic portal hypertension performed in accordance with the individualized shunt volume significantly decreases portal pressure, preserves stable hepatic hemodynamics and prevents gastro-esophageal hemorrhage.

  6. Shunt impedance measurement of the APS BBC injector

    International Nuclear Information System (INIS)

    Sun, Y.E.; Lewellen, J.W.

    2006-01-01

    The injector test stand (ITS) at Advanced Photon Source (APS) presently incorporates a ballistic bunch compression (BBC) gun, and it is used as a beam source for a number of experiments, including THz generation, beam position monitor testing for the Linac Coherent Light Source (LCLS), novel cathode testing, and radiation therapy source development. The BBC gun uses three independently powered and phased rf cavities, one cathode cell, and two full cells to provide beam energies from 2 to 10 MeV with variable energy spread, energy chirp, and, to an extent, bunch duration. The shunt impedance of an rf accelerator determines how effectively the accelerator can convert supplied rf power to accelerating gradient. The calculation of the shunt impedance can be complicated if the beam energy changes substantially during its transit through a cavity, such as in a cathode cell. We present the results of direct measurements of the shunt impedance of the APS BBC gun on an individual cavity basis, including the cathode cell, and report on achieved gradients. We also present a comparison of the measured shunt impedance with theoretical values calculated from the rf models of the cavities.

  7. Experimental Comparison of Piezoelectric and Magnetostrictive Shunt Dampers

    Science.gov (United States)

    Asnani, Vivake M.; Deng, Zhangxian; Scheidler, Justin J.; Dapino, Marcelo J.

    2016-01-01

    A novel mechanism called the vibration ring is being developed to enable energy conversion elements to be incorporated into the driveline of a helicopter or other rotating machines. Unwanted vibration is transduced into electrical energy, which provides a damping effect on the driveline. The generated electrical energy may also be used to power other devices (e.g., health monitoring sensors). PZT (piezoceramic) and PMN-30%PT (single crystal) stacks, as well as a Tb_0.3 Dy_0.7 Fe_1.92 (Terfenol-D) rod with a bias magnet array and a pickup coil, were tested as alternative energy conversion elements to use within the vibration ring. They were tuned for broadband damping using shunt resistors, and dynamic compression testing was conducted in a high-speed load frame. Energy conversion was experimentally optimized at 750Hz by tuning the applied bias stress and resistance values. Dynamic testing was conducted up to 1000Hz to determine the effective compressive modulus, shunt loss factor, internal loss factor, and total loss factor. Some of the trends of modulus and internal loss factor versus frequency were unexplained. The single crystal device exhibited the greatest shunt loss factor whereas the Terfenol-D device had the highest internal and total loss factors. Simulations revealed that internal losses in the Terfenol-D device were elevated by eddy current effects, and an improved magnetic circuit could enhance its shunt damping capabilities. Alternatively, the Terfenol-D device may be simplified to utilize only the eddy current dissipation mechanism (no pickup coil or shunt) to create broadband damping.

  8. Experimental comparison of piezoelectric and magnetostrictive shunt dampers

    Science.gov (United States)

    Asnani, Vivake M.; Deng, Zhangxian; Scheidler, Justin J.; Dapino, Marcelo J.

    2016-04-01

    A novel mechanism called the vibration ring is being developed to enable energy conversion elements to be incorporated into the driveline of a helicopter or other rotating machines. Unwanted vibration is transduced into electrical energy, which provides a damping effect on the driveline. The generated electrical energy may also be used to power other devices (e.g., health monitoring sensors). PZT (`piezoceramic') and PMN-30%PT (`single crystal') stacks, as well as a Tb0.3Dy0.7Fe1.92 (`Terfenol-D') rod with a bias magnet array and a pickup coil, were tested as alternative energy conversion elements to use within the vibration ring. They were tuned for broadband damping using shunt resistors, and dynamic compression testing was conducted in a high-speed load frame. Energy conversion was experimentally optimized at 750Hz by tuning the applied bias stress and resistance values. Dynamic testing was conducted up to 1000Hz to determine the effective compressive modulus, shunt loss factor, internal loss factor, and total loss factor. Some of the trends of modulus and internal loss factor versus frequency were unexplained. The single crystal device exhibited the greatest shunt loss factor whereas the Terfenol-D device had the highest internal and total loss factors. Simulations revealed that internal losses in the Terfenol-D device were elevated by eddy current effects, and an improved magnetic circuit could enhance its shunt damping capabilities. Alternatively, the Terfenol-D device may be simplified to utilize only the eddy current dissipation mechanism (no pickup coil or shunt) to create broadband damping.

  9. CT-control of the H-graft interposition mesocaval shunt patency

    Energy Technology Data Exchange (ETDEWEB)

    Partanen, P L.K.; Oksala, I

    1984-02-01

    A method for assessing the patency of the H-graft interposition mesocaval shunts by computerized tomography is described. Five patients with such shunts were examined with a 5.5 second CT scanner. After locating the graft a 50 cc bolus of 76% diatrizoate was injected into a cubital vein and 3-4 scans were executed at a preselected level. A distinct vessel like enhancement appeared if the shunt was open. With dynamic CT-scanning the flow can be demonstrated in graphical form as time-density curves.

  10. Transluminal angioplasty of a stenotic surgical splenorenal shunt

    International Nuclear Information System (INIS)

    Beers, B. van; Roche, A.; Cauquil, P.

    1988-01-01

    A stenosis of a side-to-side splenorenal shunt was treated by percutaneous angioplasty two years after the performance of the shunt. After dilatation, there was a fall of the splenorenal pressure gradient from 28 to 17 cm H 2 O and good transanastomotic flow was re-estabilshed. As in other arterial and venous territories, angioplasty may be an interesting alternative to surgery. (orig.)

  11. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and CT Exams Contrast Materials Venography Images related to Transjugular Intrahepatic Portosystemic Shunt (TIPS) Sponsored ...

  12. Shunted-Josephson-junction model. II. The nonautonomous case

    DEFF Research Database (Denmark)

    Belykh, V. N.; Pedersen, Niels Falsig; Sørensen, O. H.

    1977-01-01

    The shunted-Josephson-junction model with a monochromatic ac current drive is discussed employing the qualitative methods of the theory of nonlinear oscillations. As in the preceding paper dealing with the autonomous junction, the model includes a phase-dependent conductance and a shunt capacitance....... The mathematical discussion makes use of the phase-space representation of the solutions to the differential equation. The behavior of the trajectories in phase space is described for different characteristic regions in parameter space and the associated features of the junction IV curve to be expected are pointed...... out. The main objective is to provide a qualitative understanding of the junction behavior, to clarify which kinds of properties may be derived from the shunted-junction model, and to specify the relative arrangement of the important domains in the parameter-space decomposition....

  13. Staged Transcatheter Treatment of Portal Hypoplasia and Congenital Portosystemic Shunts in Children

    International Nuclear Information System (INIS)

    Bruckheimer, Elchanan; Dagan, Tamir; Atar, Eli; Schwartz, Michael; Kachko, Ludmila; Superina, Riccardo; Amir, Gabriel; Shapiro, Rivka; Birk, Einat

    2013-01-01

    Purpose: Congenital portosystemic shunts (CPSS) with portal venous hypoplasia cause hyperammonemia. Acute shunt closure results in portal hypertension. A transcatheter method of staged shunt reduction to afford growth of portal vessels followed by shunt closure is reported. Methods: Pressure measurements and angiography in the CPSS or superior mesenteric artery (SMA) during temporary occlusion of the shunt were performed. If vessels were diminutive and the pressure was above 18 mmHg, a staged approach was performed, which included implantation of a tailored reducing stent to reduce shunt diameter by ∼50 %. Recatheterization was performed approximately 3 months later. If the portal pressure was below 18 mmHg and vessels had developed, the shunt was closed with a device. Results: Six patients (5 boys, 1 girl) with a median age of 3.3 (range 0.5–13) years had CPSS portal venous hypoplasia and hyperammonemia. Five patients underwent staged closure. One patient tolerated acute closure. One patient required surgical shunt banding because a reducing stent could not be positioned. At median follow-up of 3.8 (range 2.2–8.4) years, a total of 21 procedures (20 transcatheter, 1 surgical) were performed. In all patients, the shunt was closed with a significant reduction in portal pressure (27.7 ± 11.3 to 10.8 ± 1.8 mmHg; p = 0.016), significant growth of the portal vessels (0.8 ± 0.5 to 4.0 ± 2.4 mm; p = 0.037), and normalization of ammonia levels (202.1 ± 53.6 to 65.7 ± 9.6 μmol/L; p = 0.002) with no complications. Conclusion: Staged CPSS closure is effective in causing portal vessel growth and treating hyperammonemia

  14. Conversion of Low-Flow Priapism to High-Flow State Using T-Shunt with Tunneling.

    Science.gov (United States)

    Mistry, Neil A; Tadros, Nicholas N; Hedges, Jason C

    2017-01-01

    Introduction . The three types of priapism are stuttering, arterial (high-flow, nonischemic), and venoocclusive (low-flow, ischemic). These are usually distinct entities and rarely occur in the same patient. T-shunts and other distal shunts are frequently combined with tunneling, but a seldom recognized potential complication is conversion to a high-flow state. Case Presentation . We describe 2 cases of men who presented with low-flow priapism episodes that were treated using T-shunts with tunneling that resulted with both men having recurrent erections shortly after surgery that were found to be consistent with high-flow states. Case 1 was a 33-year-old male with sickle cell anemia and case 2 was a 24-year-old male with idiopathic thrombocytopenic purpura. In both cases the men were observed over several weeks and both men returned to normal erectile function. Conclusions . Historically, proximal shunts were performed only in cases when distal shunts failed and carry a higher risk of serious complications. T-shunts and other distal shunts combined with tunneling are being used more frequently in place of proximal shunts. These cases illustrate how postoperative erections after T-shunts with tunneling can signify a conversion from low-flow to high-flow states and could potentially be misdiagnosed as an operative failure.

  15. Brain abscesses associated with right-to-left shunts in adults.

    Science.gov (United States)

    Memon, Kashif A; Cleveland, Kerry O; Gelfand, Michael S

    2012-04-01

    Although brain abscesses are frequently cryptogenic in origin, bacteria must reach the brain either by direct or hematogenous spread. Right-to-left shunts, caused either by intrapulmonary vascular malformations or congenital heart defects, may allow microorganisms to evade the normal host defenses in the lungs and lead to development of brain abscesses. Two patients recently presented with brain abscesses and were found to have conditions associated with right-to-left shunts. The diagnosis of brain abscess should prompt the clinician to consider right-to-left shunts as a possible predisposing condition for brain abscess.

  16. Balanced calibration of resonant shunt circuits for piezoelectric vibration control

    DEFF Research Database (Denmark)

    Høgsberg, Jan; Krenk, Steen

    2012-01-01

    Shunting of piezoelectric transducers and suitable electric circuits constitutes an effective passive approach to resonant vibration damping of structures. Most common design concepts for resonant resistor-inductor (RL) shunt circuits rely on either maximization of the attainable modal damping...

  17. Percutaneous gastrostomy tube placement in patients with ventriculoperitoneal shunts

    Energy Technology Data Exchange (ETDEWEB)

    Sane, S.S.; Towbin, A.; Bergey, E.A.; Kaye, R.D.; Fitz, C.R.; Albright, L.; Towbin, R.B. [Department of Radiology, Children`s Hospital of Pittsburgh, 3705 Fifth Avenue, Pittsburgh, PA 15213 (United States)

    1998-07-01

    Objective. The purpose of this study is to determine the risk of CNS and/or peritoneal infection in children with ventriculoperitoneal shunts in whom a percutaneous gastrostomy tube is placed. Materials and methods. We placed 205 gastrostomy or gastrojejunostomy tubes from January of 1991 to December 1996. Twenty-three patients (10 boys, 13 girls) had ventriculoperitoneal shunts at the time of placement. All shunts were placed at least 1 month prior to placement of the gastrostomy tube. The patients ranged in age from 8 months to 16 years with a mean age of 6 years, 9 months. Patient weight ranged from 2 kg to 60 kg. All 23 children required long-term nutritional support due to severe neurologic impairment. No prophylactic antibiotics were given prior to the procedure. Of the patients, 21/23 had a 14-F Sacks-Vine gastrostomy tube with a fixed terminal retention device inserted, using percutaneous fluoroscopic antegrade technique. Two of the 23 patients had a Ross 14-F Flexi-flo gastrostomy tube which required a retrograde technique due to a small caliber esophagus in these children. Results. All 23 children had technically successful placements of percutaneous gastrostomy (7) or gastrojejunostomy (16) tubes. Of the children, 21/23 (91 %) had no complications from the procedure. Two of 23 (9 %) patients demonstrated signs of peritonitis after placement of their gastrostomy tubes and subsequently had shunt infections. In both, children CSF culture grew gram-positive cocci. The antegrade technique was used in both children who developed peritonitis. Conclusion. Our study indicates children with ventriculoperitoneal shunts who undergo percutaneous gastrostomy are at greater risk for infection and subsequent shunt malfunction. Therefore, we recommend prophylactic antibiotic therapy to cover for skin and oral flora. (orig.) With 1 fig., 7 refs.

  18. Congenital extrahepatic portosystemic shunt associated with heterotaxy and polysplenia

    Energy Technology Data Exchange (ETDEWEB)

    Newman, Beverley [Lucile Packard Children' s Hospital, Department of Radiology, Stanford University School of Medicine, Stanford, CA (United States); Feinstein, Jeffrey A. [Stanford University School of Medicine, Division of Pediatric Cardiology, Department of Pediatrics, Lucile Packard Children' s Hospital, Stanford (United States); Cohen, Ronald A.; Patel, Hitendra [Children' s Hospital and Research Center, Department of Diagnostic Radiology, Oakland, CA (United States); Feingold, Brian; Kreutzer, Jacqueline [Children' s Hospital of Pittsburgh, Department of Pediatrics, Division of Pediatric Cardiology, Pittsburgh, PA (United States); Chan, Fandics P. [Stanford University School of Medicine, Cardiovascular Imaging Section, Department of Radiology, Lucile Packard Children' s Hospital, Stanford, CA (United States)

    2010-07-15

    Heterotaxy with polysplenia is associated with many cardiovascular anomalies including the occasional occurrence of congenital extrahepatic portosystemic shunts (CEPS). Missing this anomaly can lead to inappropriate and ineffective therapy. To emphasize the importance and associated anatomy of CEPS in conjunction with heterotaxy with polysplenia. Review of three young children who presented with cyanosis and pulmonary hypertension without a cardiac etiology. They were known (1) or discovered (2) to have heterotaxy with polysplenia. There was absence of the intrahepatic inferior vena cava (IVC) with azygos or hemiazygos continuation in all three cases. In spite of normal liver function, they were discovered to have large portosystemic shunts, splenorenal in location, along with diffuse peripheral pulmonary arterial dilatation suggestive of CEPS (Abernethy malformation) with hepatopulmonary or, more accurately, portopulmonary syndrome. All CEPS were ipsilateral to the spleens. Patency of the portal veins in these cases allowed for percutaneous shunt closure with resolution of cyanosis. CEPS is associated with heterotaxy with polysplenia and can be symptomatic because of pulmonary arteriovenous (AV) shunting. Portal and hepatic vein patency are critical for determining feasibility of CEPS closure. (orig.)

  19. A rare cause of pediatric urinary incontinence: Ventriculoperitoneal shunt with bladder perforation

    Directory of Open Access Journals (Sweden)

    Manuel C See IV

    2016-04-01

    Full Text Available We present a case of 2-year-old boy with long term dysuria and intermittent incontinence, and new onset of fever and headache. Significant past medical history includes congenital hydrocephalus with a ventriculoperitoneal shunt placement two years prior to consult. On physical examination, a tubular structure was noted underneath the prepuce suspected to be the distal tip of ventriculoperitoneal shunt, which was confirmed by kidney, ureter and bladder (KUB X-ray and CT scan. Patient was treated with a novel approach of extraperitoneal removal of ventriculoperitoneal shunt distal tip with cystorrhaphy via a low transverse pfannenstiel incision, separate left ventriculostomy tube insertion and complete removal of ventriculoperitoneal shunt from the right ventricle. This report accounts a rare pediatric case with ventriculoperitoneal shunt perforation into a normal bladder successfully treated with mini-open surgery.

  20. Prenatal surgery for myelomeningocele and the need for cerebrospinal fluid shunt placement

    Science.gov (United States)

    Tulipan, Noel; Wellons, John C.; Thom, Elizabeth A.; Gupta, Nalin; Sutton, Leslie N.; Burrows, Pamela K.; Farmer, Diana; Walsh, William; Johnson, Mark P.; Rand, Larry; Tolivaisa, Susan; D’Alton, Mary E.; Adzick, N. Scott

    2016-01-01

    Object The Management of Myelomeningocele Study (MOMS) was a multicenter randomized trial comparing the safety and efficacy of prenatal and postnatal closure of myelomeningocele. The trial was stopped early because of the demonstrated efficacy of prenatal surgery, and outcomes on 158 of 183 pregnancies were reported. Here, the authors update the 1-year outcomes for the complete trial, analyze the primary and related outcomes, and evaluate whether specific prerandomization risk factors are associated with prenatal surgery benefit. Methods The primary outcome was a composite of fetal loss or any of the following: infant death, CSF shunt placement, or meeting the prespecified criteria for shunt placement. Primary outcome, actual shunt placement, and shunt revision rates for prenatal versus postnatal repair were compared. The shunt criteria were reassessed to determine which were most concordant with practice, and a new composite outcome was created from the primary outcome by replacing the original criteria for CSF shunt placement with the revised criteria. The authors used logistic regression to estimate whether there were interactions between the type of surgery and known prenatal risk factors (lesion level, gestational age, degree of hindbrain herniation, and ventricle size) for shunt placement, and to determine which factors were associated with shunting among those infants who underwent prenatal surgery. Results Ninety-one women were randomized to prenatal surgery and 92 to postnatal repair. The primary outcome occurred in 73% of infants in the prenatal surgery group and in 98% in the postnatal group (p < 0.0001). Actual rates of shunt placement were only 44% and 84% in the 2 groups, respectively (p < 0.0001). The authors revised the most commonly met criterion to require overt clinical signs of increased intracranial pressure, defined as split sutures, bulging fontanelle, or sunsetting eyes, in addition to increasing head circumference or hydrocephalus. Using

  1. Clopidogrel in infants with systemic-to-pulmonary-artery shunts

    DEFF Research Database (Denmark)

    Wessel, David L; Berger, Felix; Li, Jennifer S

    2013-01-01

    BACKGROUND: Infants with cyanotic congenital heart disease palliated with placement of a systemic-to-pulmonary-artery shunt are at risk for shunt thrombosis and death. We investigated whether the addition of clopidogrel to conventional therapy reduces mortality from any cause and morbidity relate......-related morbidity. (Funded by Sanofi-Aventis and Bristol-Myers Squibb; ClinicalTrials.gov number, NCT00396877.)....

  2. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Transjugular Intrahepatic Portosystemic Shunt ( ...

  3. Prevention and treatment of complications after transjugular intrahepatic portosystemic shunt

    Directory of Open Access Journals (Sweden)

    XUE Hui

    2016-02-01

    Full Text Available The application of transjugular intrahepatic portosystemic shunt (TIPS in the treatment of cirrhotic portal hypertension has been widely accepted both at home and abroad. This article focuses on the fatal complications of TIPS (including intraperitoneal bleeding and acute pulmonary embolism, shunt failure, and recurrent portosystemic hepatic encephalopathy, and elaborates on the reasons for such conditions and related preventive measures, in order to improve the accuracy and safety of intraoperative puncture, reduce common complications such as shunt failure and hepatic encephalopathy, and improve the clinical effect of TIPS in the treatment of cirrhotic portal hypertension.

  4. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... a stent is placed to keep the connection open and allow it to bring blood draining from ... veins within the liver. The shunt is kept open by the placement of a small, tubular metal ...

  5. Intracranial Pressure-Guided Shunt Valve Adjustments with the Miethke Sensor Reservoir.

    Science.gov (United States)

    Antes, Sebastian; Stadie, Axel; Müller, Simon; Linsler, Stefan; Breuskin, David; Oertel, Joachim

    2018-01-01

    Telemetric intracranial pressure (ICP) monitoring seems to be a promising therapy-supporting option in shunt-treated patients. Benefits become obvious when headaches are unspecific and clinical symptoms cannot be related to possible overdrainage or underdrainage. In this study, we evaluated a new telemetric device to individually adjust shunt valves according to ICP measurements. Between December 2015 and November 2016, 25 patients with suspected suboptimal shunt valve settings underwent insertion of a telemetric ICP sensor (Sensor Reservoir; Christoph Miethke, Potsdam, Germany). Over a 1-year period, a total of 183 telemetric ICP measurements and 85 shunt valve adjustments were carried out. Retrospective statistic analyses focused on valve adjustments, ICP values, and clinical outcomes. ICP-guided valve adjustments positively changed the clinical state in 18 out of 25 patients. Clinical improvement over time was associated with significant changes of the valve settings and ICP values. Interestingly, a therapeutically normalized ICP profile was not automatically associated with clinical improvement. The Sensor Reservoir is an important and valuable tool for shunt-treated patients suffering from drainage-related problems. The possibility to simultaneously recognize and solve shunt problems represents the decisive advantage. Nevertheless, measurements with the Sensor Reservoir did not allow for the determination of default valve settings or universal target ICP values. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Clinical and ultrasonographic criteria for using ventriculoperitoneal shunts in newborns with myelomeningocele

    Directory of Open Access Journals (Sweden)

    Jose Roberto Tude Melo

    2015-09-01

    Full Text Available Objective Hydrocephalus is one of the main complications associated with myelomeningocele (MM. This study aimed to identify clinical and ultrasonographic criteria for using ventriculoperitoneal (VP shunts in this group of patients.Method A retrospective cohort study, based on established protocol for VP shunt implant in hydrocephalic children with MM. Parameters used to guide the indication of VP shunts included measurement of head circumference (HC, evaluation of fontanels, and measurement of lateral ventricular atrium (LVA width by transcranial ultrasonography.Results 43 children were included in the analysis, of which 74% had hydrocephalus and required a VP shunt. These children had LVA width ≥ 15 mm, showed increased HC, or had bulging fontanels.Conclusion VP shunt is required in children with increased HC (≥ 2 standard deviation regarding age group, bulging fontanels, or LVA width of ≥ 15 mm after the closure of MM.

  7. Communicating hydrocephalus due to cerebral venous sinus thrombosis treated with ventriculoperitoneal shunt

    Directory of Open Access Journals (Sweden)

    Rahul T Chakor

    2012-01-01

    Full Text Available Cerebral venous sinus thrombosis (CVT is a rare cerebrovascular disease with variable presentation. CVT rarely causes hydrocephalus. Communicating hydrocephalus due to CVT is extremely rare. We describe a patient of CVT presenting with chronic headache and communicating hydrocephalus. The patient was successfully treated with ventriculoperitoneal (VP shunt. A 40 year old man presented with moderate to severe headache since six months and progressive visual loss since two months. Head Computed tomogram showed mild hydrocephalus without obstruction. Lumbar puncture (LP demonstrated elevated pressure but was otherwise normal. Magnetic resonance venogram showed extensive CVT. Repeated CSF drainage and thecoperitoneal shunt did not relieve the severe headache hence a VP shunt was placed. Post shunt headache subsided with resolution of hydrocephalus. CVT can present as communicating hydrocephalus. Gradual reduction of intra-ventricular pressure by repeated LPs followed by VP shunt can safely treat hydrocephalus due to CVT.

  8. Renal Arteriovenous Shunts: Clinical Features, Imaging Appearance, and Transcatheter Embolization Based on Angioarchitecture.

    Science.gov (United States)

    Maruno, Miyuki; Kiyosue, Hiro; Tanoue, Shuichi; Hongo, Norio; Matsumoto, Shunro; Mori, Hiromu; Sagara, Yoshiko; Kashiwagi, Junji

    2016-01-01

    Renal arteriovenous (AV) shunt, a rare pathologic condition, is divided into two categories, traumatic and nontraumatic, and can cause massive hematuria, retroperitoneal hemorrhage, pain, and high-output heart failure. Although transcatheter embolization is a less-invasive and effective treatment option, it has a potential risk of complications, including renal infarction and pulmonary embolism, and a potential risk of recanalization. The successful embolization of renal AV shunt requires a complete occlusion of the shunted vessel while preventing the migration of embolic materials and preserving normal renal arterial branches, which depends on the selection of adequate techniques and embolic materials for individual cases, based on the etiology and imaging angioarchitecture of the renal AV shunts. A classification of AV malformations in the extremities and body trunk could precisely correspond with the angioarchitecture of the nontraumatic renal AV shunts. The selection of techniques and choice of adequate embolic materials such as coils, vascular plugs, and liquid materials are determined on the basis of cause (eg, traumatic vs nontraumatic), the classification, and some other aspects of the angioarchitecture of renal AV shunts, including the flow and size of the fistulas, multiplicity of the feeders, and endovascular accessibility to the target lesions. Computed tomographic angiography and selective digital subtraction angiography can provide precise information about the angioarchitecture of renal AV shunts before treatment. Color Doppler ultrasonography and time-resolved three-dimensional contrast-enhanced magnetic resonance angiography represent useful tools for screening and follow-up examinations of renal AV shunts after embolization. In this article, the classifications, imaging features, and an endovascular treatment strategy based on the angioarchitecture of renal AV shunts are described. (©)RSNA, 2016.

  9. Study on the Automatic Detection Method and System of Multifunctional Hydrocephalus Shunt

    Science.gov (United States)

    Sun, Xuan; Wang, Guangzhen; Dong, Quancheng; Li, Yuzhong

    2017-07-01

    Aiming to the difficulty of micro pressure detection and the difficulty of micro flow control in the testing process of hydrocephalus shunt, the principle of the shunt performance detection was analyzed.In this study, the author analyzed the principle of several items of shunt performance detection,and used advanced micro pressure sensor and micro flow peristaltic pump to overcome the micro pressure detection and micro flow control technology.At the same time,This study also puted many common experimental projects integrated, and successfully developed the automatic detection system for a shunt performance detection function, to achieve a test with high precision, high efficiency and automation.

  10. A metabolomics-based method for studying the effect of yfcC gene in Escherichia coli on metabolism.

    Science.gov (United States)

    Wang, Xiyue; Xie, Yuping; Gao, Peng; Zhang, Sufang; Tan, Haidong; Yang, Fengxu; Lian, Rongwei; Tian, Jing; Xu, Guowang

    2014-04-15

    Metabolomics is a potent tool to assist in identifying the function of unknown genes through analysis of metabolite changes in the context of varied genetic backgrounds. However, the availability of a universal unbiased profiling analysis is still a big challenge. In this study, we report an optimized metabolic profiling method based on gas chromatography-mass spectrometry for Escherichia coli. It was found that physiological saline at -80°C could ensure satisfied metabolic quenching with less metabolite leakage. A solution of methanol/water (21:79, v/v) was proved to be efficient for intracellular metabolite extraction. This method was applied to investigate the metabolome difference among wild-type E. coli, its yfcC deletion, and overexpression mutants. Statistical and bioinformatic analysis of the metabolic profiling data indicated that the expression of yfcC potentially affected the metabolism of glyoxylate shunt. This finding was further validated by real-time quantitative polymerase chain reactions showing that expression of aceA and aceB, the key genes in glyoxylate shunt, was upregulated by yfcC. This study exemplifies the robustness of the proposed metabolic profiling analysis strategy and its potential roles in investigating unknown gene functions in view of metabolome difference. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... Intrahepatic Portosystemic Shunt (TIPS)? What are some common uses of the procedure? How should I prepare? What does the equipment look like? How does the procedure work? How is the procedure performed? What will I ...

  12. Endoscopic Third Ventriculostomy Instead of Shunt Revision in Children Younger Than 3 Years of Age.

    Science.gov (United States)

    Zhao, Rui; Shi, Wei; Yang, Haowei; Li, Hao

    2016-04-01

    Endoscopic third ventriculostomy (ETV) is a valuable option in the treatment of shunt failure, but no clinical data exist for young children. The aim of this study was to elucidate the role of ETV in patients younger than 3 years of age with shunt malfunction. A cohort of 37 patients younger than 3 years of age with shunt malfunction underwent ETV instead of shunt revision. Patients' preoperative condition and medical history were studied to determine the impact of a number of variables on outcome. The Fisher exact test was used to assess differences among groups. Median age at ETV was 21.6 months (8-36 months). Diagnosis was obstructive hydrocephalus in 24 patients and communicating hydrocephalus in 13. Median age at initial shunt placement was 3.2 months (10 days to 30 months). The etiology of shunt malfunction was obstruction (n = 27) or infection (n = 10). Overall ETV failure rate was 40.5% (15/37). Patients whose age at initial shunt placement was <6 months and/or who had a preterm birth history had higher relative rates of ETV failure. Other variables, including type of hydrocephalus, interval between initial shunt placement and ETV, history of intraventricular bleeding and/or infection, and etiology of shunt malfunction, did not significantly affect the final outcome. Patients younger than 3 years with obstructive or communicating hydrocephalus may benefit from ETV in the event of shunt malfunction and have about a 60% probability of becoming shunt free. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Percutaneous Transjugular Direct Porto-caval Shunt in Patients with Budd-Chiari Syndrome

    International Nuclear Information System (INIS)

    Quateen, A.; Pech, M.; Berg, T.; Bergk, A.; Podrabsky, P.; Felix, R.; Ricke, J.

    2006-01-01

    The purpose of the study was to evaluate the feasibility and effectiveness of direct porto-caval shunts in patients with Budd-Chiari syndrome (BCS) in whom there is no access to the hepatic veins during transjugular intrahepatic portosystemic shunt (TIPSS). We included six consecutive patients with fulminant/acute Budd-Chiari syndrome (mean age: 35 years) in whom a conventional TIPSS was not possible due to inaccessible hepatic veins. We performed a direct porto-caval shunt via a transhepatic approach. Patients were followed up by means of clinical examination, laboratory investigations, and Doppler ultrasound. TIPSS implantation from the inferior vena cava (IVC) was successful in all six patients (100%). The median transhepatic shunt length was 9 cm (8-10 cm). No procedure-related complications were observed in our patients. Early shunt occlusion occurred in three out of six patients (50%). In all three of these patients, the stent used to stabilize the shunt ended 1-2 cm before reaching the IVC. All occlusions were successfully recanalized. One of these patients developed recurrent early shunt as well as mesenteric and splenic vein occlusions. She died 7 days after TIPSS placement due to an unmanageable coagulation disorder. The remaining five patients were followed up by planned clinical examination and laboratory investigations (mean follow-up time was 15 months; patient 1 was followed up for 13 months, patient 2 for 14 months, patient 3 for 15 months, and patients 4 and 5 for 16 months) and all displayed a complete and durable resolution of liver failure and ascites without reintervention. In patients with acute liver failure originating from BCS and inaccessible hepatic veins, a direct transhepatic porto-caval shunt can be performed safely and effectively under ultrasound guidance. Future studies in larger patient groups should investigate if the patency of transcaval TIPSS with long transhepatic shunt segments is similar compared to conventional TIPSS via

  14. Spontaneous knot; a rare cause of ventriculoperitoneal shunt blockage.

    LENUS (Irish Health Repository)

    Mohammed, Wail

    2011-02-01

    A 14-year old X linked congenital hydrocephalus presented with unexplained headaches and vomiting. He had external ventricular drain and intracranial pressure monitoring (ICP). Subsequently, he underwent exploration and removal of previously inserted ventriculoperitoneal (VP) shunts. On retrieval of peritoneal catheters a double knot was noted between his two distal catheters. This case illustrates a rare cause of ventriculoperitoneal shunt malfunction.

  15. Spontaneous knot; a rare cause of ventriculoperitoneal shunt blockage.

    LENUS (Irish Health Repository)

    Mohammed, Wail

    2012-02-01

    A 14-year old X linked congenital hydrocephalus presented with unexplained headaches and vomiting. He had external ventricular drain and intracranial pressure monitoring (ICP). Subsequently, he underwent exploration and removal of previously inserted ventriculoperitoneal (VP) shunts. On retrieval of peritoneal catheters a double knot was noted between his two distal catheters. This case illustrates a rare cause of ventriculoperitoneal shunt malfunction.

  16. Secondary pediatric encephalocele after ventriculosubgaleal shunting for posthemorrhagic hydrocephalus.

    Science.gov (United States)

    Seeburg, Daniel; Ahn, Edward; Huisman, Thierry

    2014-08-01

    Intraventricular hemorrhage and posthemorrhagic hydrocephalus continue to be common complications in very low-birth-weight premature infants, often requiring ventricular shunting for cerebrospinal fluid diversion. We report on two infants with posthemorrhagic hydrocephalus that developed a secondary encephalocele after ventriculosubgaleal shunting. Encephaloceles can act as a source of seizure activity and can result in various additional complications including meningitis, abscess formation, and infarction of herniated brain parenchyma. With continued improvements in neonatal intensive care, the survival of infants with significant medical comorbidities-including those that develop posthemorrhagic hydrocephalus requiring ventricular shunting-continues to increase. It is thus important for the radiologist and treating physician to be aware of this rare, potential complication. Georg Thieme Verlag KG Stuttgart · New York.

  17. Impaired arm development after Blalock-Taussig shunts in adults with repaired tetralogy of Fallot.

    Science.gov (United States)

    Le Gloan, Laurianne; Marcotte, François; Leduc, Hugues; Mercier, Lise-Andrée; Dore, Annie; Mongeon, François-Pierre; Ibrahim, Reda; Miro, Joaquim; Asgar, Anita; Poirier, Nancy; Khairy, Paul

    2013-09-30

    Many adults with repaired tetralogy of Fallot have had prior Blalock-Taussig shunts. These shunts may theoretically hinder growth and development of the ipsilateral arm. We prospectively enrolled consecutive patients with tetralogy of Fallot in a cross-sectional study to measure arm length and assess handgrip strength. Bilateral handgrip strength was quantified by a dynamometer in a standing position after instructing patients to clench each hand tightly in succession. The maximum force achieved, in kilograms, was measured. A total of 80 consecutive adults with tetralogy of Fallot, aged 36.0 ± 12.5 years, 49% female, were prospectively enrolled. Thirty-eight (47.5%) patients had prior Blalock-Taussig shunts at a median age of 1.0 year. Twenty-one (55.3%) were left-sided and 23 (60.5%) were classic shunts. All but six patients with right-sided shunts and one without a prior shunt were right-handed. The shunts were present for a median of 4.0 years prior to takedown during corrective surgery. The arm ipsilateral to the shunt was significantly shorter than the contralateral arm (71.5 ± 6.1 versus 73.6 ± 5.6 cm, Ptetralogy of Fallot, Blalock-Taussig shunts may impair normal development of the ipsilateral arm with repercussions in adulthood that include shorter limb length and reduced handgrip strength. These changes are most pronounced in patients with classic end-to-side anastomoses. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  18. Creation of transcatheter aortopulmonary and cavopulmonary shunts using magnetic catheters: feasibility study in swine.

    Science.gov (United States)

    Levi, Daniel S; Danon, Saar; Gordon, Brent; Virdone, Nicky; Vinuela, Fernando; Shah, Sanjay; Carman, Greg; Moore, John W

    2009-05-01

    Surgical shunts are the basic form of palliation for many types of congenital heart disease. The Glenn shunt (superior cavopulmonary connection) and central shunt (aortopulmonary connection) represent surgical interventions that could potentially be accomplished by transcatheter techniques. We sought to investigate the efficacy of using neodymium iron boron (NdFeB) magnetic catheters to create transcatheter cavopulmonary and aortopulmonary shunts. NdFeB magnets were machined and integrated into catheters. "Target" catheters were placed in the pulmonary arteries (PAs), and radiofrequency "perforation" catheters were placed in either the descending aorta (DAo) for central shunts or the superior vena cava (SVC) for Glenn shunts. The magnet technique or "balloon target" method was used to pass wires from the DAo or the SVC into the PA. Aortopulmonary and cavopulmonary connections were then created using Atrium iCAST covered stents. Magnet catheters were used to perforate the left pulmonary artery from the DAo, thereby establishing a transcatheter central shunt. Given the orientation of the vasculature, magnetic catheters could not be used for SVC-to-PA connections; however, perforation from the SVC to the right pulmonary artery was accomplished with a trans-septal needle and balloon target. Transcatheter Glenn or central shunts were successfully created in four swine.

  19. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... story about radiology? Share your patient story here Images × Image Gallery Radiologist and patient consultation. View full size ... X-Ray and CT Exams Contrast Materials Venography Images related to Transjugular Intrahepatic Portosystemic Shunt (TIPS) Sponsored ...

  20. Forty years of shunt surgery at Rigshospitalet, Denmark

    DEFF Research Database (Denmark)

    Mansson, Philip Kofoed; Johansson, Sofia; Ziebell, Morten

    2017-01-01

    Objective The objective of this study is to review our experience of shunt surgery by investigating 40years of development in terms of rates of revision and infection, shunt survival and risk factors. Design and participants Medical records and operative reports were reviewed retrospectively...... for all patients who underwent primary shunt surgery at our department in the years 2010 to 2012. All results were compared with a previous study from our department. A mixed population consisting of 434 patients was included. Adults (≥15years) accounted for 89.9% of all patients and the mean follow.......1-54.9). Within 4weeks postoperatively, 3.2% had an infection and overall infection rate was 5.5%. Short duration of surgery and the use of antibiotic prophylaxis were associated with a lower risk of infection. The most frequent causes of revision were valve defects (18.4%) and proximal defects or obstructions...

  1. Gaseous environment of plants and activity of enzymes of carbohydrate catabolism

    International Nuclear Information System (INIS)

    Ivanov, B.F.; Zemlyanukhin, A.A.; Igamberdiev, A.U.; Salam, A.M.M.

    1989-01-01

    The authors investigated the action of hypoxia and high CO 2 concentration in the atmosphere on activity of phosphofructokinase, aldolase, glucose phosphate isomerase, glucose-6-phosphate dehydrogenase, lactate dehydrogenase, alcohol dehydrogenase, and isocitrate lyase in pea seedlings (Pisum sativum L.), corn scutella (Zea mays L.), and hemp cotyledons (Cannabis sativa L.). The first 4-12h of hypoxia witnessed suppression of enzymes of the initial stages of glycolysis (glucose-6-phosphate isomerase, phosphofructokinase)and activation of enzymes of its final stages (alcohol dehydrogenase and lactate dehydrogenase) and enzymes linking glycolysis and the pentose phosphate pathway (aldolase and glucose-6-phosphate dehydrogenase). An excess of CO 2 in the environment accelerated and amplified this effect. At the end of a 24-h period of anaerobic incubation, deviations of enzyme activity from the control were leveled in both gaseous environments. An exception was observed in the case of phosphofructokinase, whose activity increased markedly at this time in plants exposed to CO 2 . Changes in activity of the enzymes were coupled with changes in their kinetic parameters (apparent K m and V max values). The activity of isocitrate lyase was suppressed in both variants of hypoxic gaseous environments, a finding that does not agree with the hypothesis as to participation of the glyoxylate cycle in the metabolic response of plants to oxygen stress. Thus, temporary inhibition of the system of glycolysis and activation of the pentose phosphate pathway constituted the initial response of the plants to O 2 stress, and CO 2 intensified this metabolic response

  2. Shunt hybrid active power filter for harmonic mitigation: A practical ...

    Indian Academy of Sciences (India)

    The increasing importance of Power Quality problems has been responsible for several improvements in Active Power Filter (APF) typologies in the last decade. The increased cost and switching losses make a pure shunt APF economically impractical for high power applications. In higher power levels shunt Hybrid Active ...

  3. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... Portosystemic Shunt (TIPS) Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ... links: For the convenience of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo.org , ACR ...

  4. Biophysical shunt theory for neuropsychopathology: Part I.

    Science.gov (United States)

    Naisberg, Y; Avnon, M; Weizman, A

    1995-11-01

    We present a new model of the origin of schizophrenia based on biophysical ionic shunts in neuronal (electrical) pathways. Microstructural and molecular evidence is presented for the way in which changes in the neuronal membrane ionic channels may facilitate membrane property rearrangement, leading to a change in the density and composition of the ion channel charge which in turn causes a change in ionic flow orientation and distribution. We suggest that, under abnormal conditions, ionic flow shunts are created which redirect the biophysical collateral neuronal (electrical) pathways, resulting in psychiatric signs and symptoms. This model is complementary to the biological basis of schizophrenia.

  5. Detection of intracardiac shunts with contrast-enhanced dynamic MR imaging

    International Nuclear Information System (INIS)

    Manning, W.J.; Atkinson, D.J.; Parker, J.A.; Edelman, R.R.

    1990-01-01

    This paper reports on ultrafast MR imaging with bolus administration of Gd-DTPA used to detect intracardiac shunts. Ten patients who had recently undergone cardiac catheterization or first-pass radionuclide evaluation were selected for study. These included five patients without intracardiac shunts and five patients with shunts (three with atrial septal defect, two with ventricular septal defect). Resting four-chamber cardiac images were obtained during intravenous injection of Gd-DTPA (0.02 mmol/kg) with an ultrafast, T1-weighted sequence. Images were acquired over 380 msec, with repetitive images obtained with each QRS for 50 beats. In addition, standard MR cine examinations were performed

  6. Leakage Inductance Calculation for Planar Transformers with a Magnetic Shunt

    DEFF Research Database (Denmark)

    Zhang, Jun; Ouyang, Ziwei; Duffy, Maeve C.

    2014-01-01

    with a magnetic shunt by means of the stored magnetic energy in the primary and secondary sides of the transformer using the magnetomotive force (MMF) variation method, as well as the stored energy in the shunt based on the reluctance model. The detailed calculation method is described. Both the FEA simulation...

  7. Radionuclide cisternography in diagnostics of obstruction hydrocephalus in introduced ventricculoperitoneal shunt

    International Nuclear Information System (INIS)

    Cernochova, I.; Lipina, R.

    2004-01-01

    To confirm or exclude a diagnosis of internal obstruction hydrocephalus in an 8-year old girl with an introduced ventriculoperitoneal (V-P) shunt Establishing the V-P shunt is indisputably the route of choice in non-communicating hydrocephalus. The existence of a V-P shunt, however, is connected with numerous risks, especially of injuries, infection as well as increased intraabdominal pressure - e.g. in pregnancy. The development of endoscopy in neurosurgery allows the creation of communication via the bottom of the third ventricle with basal cisterns, and the subsequent cancellation of a V-P shunt. We describe the case of an 8-year old girl with congenital internal hydrocephalus with an assumed obliteration of the Sylvian aqueduct with an established V-P shunt. An MR scan described the membrane in the area of the Sylvian aqueduct, but the disproportion between the dilatation of the lateral ventricles, third ventricle and fourth ventricle led the physician to doubt as to the accuracy of the diagnosis of internal obstruction hydrocephalus. Therefore we performed a radionuclide cisternography (in a modified manner), which proved an existing communication between the third and fourth cerebral ventricle and which contradicted the clinical diagnosis of obstruction hydrocephalus. (author)

  8. Shunt-dependent hydrocephalus: management style among members of the American Society of Pediatric Neurosurgeons.

    Science.gov (United States)

    Kraemer, Mark R; Sandoval-Garcia, Carolina; Bragg, Taryn; Iskandar, Bermans J

    2017-09-01

    OBJECTIVE The authors conducted a survey to evaluate differences in the understanding and management of shunt-dependent hydrocephalus among members of the American Society of Pediatric Neurosurgeons (ASPN). METHODS Surveys were sent to all 204 active ASPN members in September 2014. One hundred thirty responses were received, representing a 64% response rate. Respondents were asked 13 multiple-choice and free-response questions regarding 4 fundamental problems encountered in shunted-hydrocephalus management: shunt malfunction, chronic cerebrospinal fluid (CSF) overdrainage, chronic headaches, and slit ventricle syndrome (SVS). RESULTS Respondents agreed that shunt malfunction occurs most often as the result of ventricular catheter obstruction. Despite contrary evidence in the literature, most respondents (66%) also believed that choroid plexus is the tissue most often found in obstructed proximal catheters. However, free-text responses revealed that the respondents' understanding of the underlying pathophysiology of shunt obstruction was highly variable and included growth, migration, or adherence of choroid plexus, CSF debris, catheter position, inflammatory processes, and CSF overdrainage. Most respondents considered chronic CSF overdrainage to be a rare complication of shunting in their practice and reported wide variation in treatment protocols. Moreover, despite a lack of evidence in the literature, most respondents attributed chronic headaches in shunt patients to medical reasons (for example, migraines, tension). Accordingly, most respondents managed headaches with reassurance and/or referral to pain clinics. Lastly, there were variable opinions on the etiology of slit ventricle syndrome (SVS), which included early shunting, chronic overdrainage, and/or loss of brain compliance. Beyond shunt revision, respondents reported divergent SVS treatment preferences. CONCLUSIONS The survey shows that there is wide variability in the understanding and management of

  9. Successful Embolization of a Spontaneous Mesocaval Shunt Using the Amplatzer Vascular Plug II

    International Nuclear Information System (INIS)

    Boixadera, Helena; Tomasello, Alejandro; Quiroga, Sergi; Cordoba, Joan; Perez, Mercedes; Segarra, Antoni

    2010-01-01

    A 48-year-old man with alcoholic liver cirrhosis and hepatic encephalopathy was found to have a large, spontaneous mesocaval shunt. The shunt was successfully occluded with the use of an Amplatzer Vascular Plug. To our knowledge, this is the first report of the use of this device to embolize a mesocaval shunt involving the superior mesenteric vein.

  10. Two-port laparoscopic management of a giant pseudocyst complicating ventriculoperitoneal shunt

    Directory of Open Access Journals (Sweden)

    Sandesh V Parelkar

    2014-01-01

    Full Text Available Insertion of a ventriculo-peritoneal (VP shunt is the most common operative procedure for the treatment of hydrocephalus in children. Of the several causes of shunt malfunction, cerebrospinal fluid (CSF pseudocyst is relatively uncommon. There are several modalities to treat a CSF pseudocyst. Laparotomy is required, at times, more than once. We managed a patient of CSF pseudocyst with two-port laparoscopy, by deroofing the psuedocyst and repositioning of the shunt. This minimally invasive technique avoids morbidity associated with laparotomy and aids in early recovery.

  11. Association between right-to-left shunts and brain lesions in sport divers.

    Science.gov (United States)

    Gerriets, Tibo; Tetzlaff, Kay; Hutzelmann, Alfred; Liceni, Thomas; Kopiske, Gerrit; Struck, Niklas; Reuter, Michael; Kaps, Manfred

    2003-10-01

    Recent studies suggest that healthy sport divers may develop clinically silent brain damage, based on the association between a finding of multiple brain lesions on MRI and the presence of right-to-left shunt, a pathway for venous gas bubbles to enter the arterial system. We performed echocontrast transcranial Doppler sonography in 42 sport divers to determine the presence of a right-to-left shunt. Cranial MRI was carried out using a 1.5 T magnet. A lesion was counted if it was hyperintense on both T2-weighted and T2-weighted fluid attenuated inversion recovery sequences. To test the hypothesis that the occurrence of postdive arterial gas emboli is related to brain lesions on MRI, we measured postdive intravascular bubbles in a subset of 15 divers 30 min after open water scuba dives. Echocontrast transcranial Doppler sonography revealed a right-to-left shunt in 16 of the divers (38%). Only one hyperintensive lesion of the central white matter was found and that was in a diver with no evidence of a right-to-left shunt. Postdive arterial gas emboli were detected in 3 out of 15 divers; they had a right-to-left shunt, but no pathologic findings on cranial magnetic resonance imaging. Our data support the theory that right-to-left shunts can serve as a pathway for venous gas bubbles into the arterial circulation. However, we could not confirm an association between brain lesions and the presence of a right-to-left shunt in sport divers.

  12. Tunable band gaps in acoustic metamaterials with periodic arrays of resonant shunted piezos

    International Nuclear Information System (INIS)

    Chen Sheng-Bing; Wen Ji-Hong; Wang Gang; Wen Xi-Sen

    2013-01-01

    Periodic arrays of resonant shunted piezoelectric patches are employed to control the wave propagation in a two-dimensional (2D) acoustic metamaterial. The performance is characterized by the finite element method. More importantly, we propose an approach to solving the conventional issue of the nonlinear eigenvalue problem, and give a convenient solution to the dispersion properties of 2D metamaterials with periodic arrays of resonant shunts in this article. Based on this modeling method, the dispersion relations of a 2D metamaterial with periodic arrays of resonant shunted piezos are calculated. The results show that the internal resonances of the shunting system split the dispersion curves, thereby forming a locally resonant band gap. However, unlike the conventional locally resonant gap, the vibrations in this locally resonant gap are unable to be completely localized in oscillators consisting of shunting inductors and piezo-patches

  13. A novel method for passing cerebrospinal fluid shunt tubing: a proof of principle study.

    Science.gov (United States)

    Tubbs, R Shane; Goodrich, Dylan; Tubbs, Isaiah; Loukas, Marios; Cohen-Gadol, Aaron A

    2014-12-01

    Few innovations in the method of tunneling shunt tubing for cerebrospinal fluid (CSF) shunt diversion have been made since this treatment of hydrocephalus was first developed. Therefore, this feasibility study was performed with the hope of identifying an improved technique that could potentially carry fewer complications. On 10 cadaver sides and when placed in the supine position, small skin incisions were made at the clavicle and ipsilateral subcostal region, and magnets were used to pass standard shunt tubing between the two incisions. Nickel-plated magnets were less effective in pulling the shunt tubing below the skin compared with ceramic magnets. Of these, magnets with pull strengths of 150-200 lbs were the most effective in dragging the subcutaneous tubing between the two incisions. No obvious damage to the skin from the overlying magnet was seen in any specimen. Few options exist for tunneling distal shunt tubing for CSF shunt procedures. Future patient studies are needed to determine if the technique described herein is superior to current methods, particularly when examining patient groups that are at a greater risk for injury during tunneling shunt catheters.

  14. Nonconventional mesocaval prosthetic shunt interposition in ...

    African Journals Online (AJOL)

    years demonstrates shunt patency and normal development ... However, the child's condition and growth ... The child has satisfactory weight and growth gain. (40kg .... infants and toddlers: replacement with decellularized branched pulmonary.

  15. Imaging of the ventriculoperitoneal shunt-related complications in infants and children with hydrocephalus

    International Nuclear Information System (INIS)

    Jeon, Se Ok; Kim, Ji Hye; Oh, Eun Young; Hwang, Hee Young; Lee, Seon Kyu; Lee, Eun Joo; Kwak, Min Sook; Kim, Hyung Sik

    1999-01-01

    To evaluate the frequency and imaging findings of various ventriculo-peritoneal shunt-related complications in pediatric patients with hydrocephalus. We retrospectively reviewed 246 plain radiographs, three shuntograms, 53 ultrasounds, 133 CT scans, and 24 MR images obtained before and after the ventriculo-peritoneal shunt procedure in 33 pediatric patients with hydrocephalus. Using preoperative images, the etiology of the hydrocephalus was assessed. Changes in the size and shape of the ventricles, the location and continuity of shunt apparatus, and the presence of any abnormal enhancement, hemorrhage, edema or tissue loss, or other findings of complications, were analyzed on postoperative images ; the frequency and imaging findings of shunt-related complications such as shunt malfunction, infection, homorrhage or isolated ventricle, and complications caused by overdrainage, were thus evaluated. The frequency of such complications was analyzed according to the etiology of the hydrocephalus, and in addition, medical records were reviewed and correlated with imaging findings. In 18 of the 33 patients(54%), a total of 31 complications was detected. These were present in four of five cases (80%) of hydrocephalus caused by meningitis and ventriculitis, seven of twelve (58%) intraventricular hemorrhage, two of four (50%) unknown cases, three of nine (33%) congenital malformations, one of two (50%) tumors, and one (100%) congenital infection. Shunt malfunction was most common (n=15), and was accompanied by findings of enlarged ventricles, periventricular and peritubal edema, and abnormal location of the shunt tube. Symptoms and signs of increased intracranial pressure were also noted. Subdural hemorrhage and infection were present in four cases each ; findings of infection were enhancement of the ventricular wall, meninges, and parenchyma, as well as sonographically noted intraventricular septation and increased ventricular wall echo. Isolated lateral ventricle (n=4) or 4

  16. Transmicrocatheter local injection of ethanol to treat hepatocellular carcinoma with high flow arteriovenous shunts

    International Nuclear Information System (INIS)

    Guan Shouhai; Shan Hong; Jiang Zaibo; Huang Mingsheng; Zhu Kangshun; Li Zhengran; Meng Xiaochun

    2002-01-01

    Objective: To evaluate the feasibility and clinical effect of embolization therapy in treating the high flow hepatic arteriovenous shunts in hepatocellular carcinoma (HCC) by locally injected ethanol through microcatheter. Methods: Forty-one branches of arteriovenous shunts were treated by local ethanol infusion through microcatheter in 29 patients suffered with HCC. Angiography was performed to observe the embolization effect and influence to non-targeted vessels. Result: Forty-one branches of arteriovenous shunts in 29 patients were injected with ethanol locally. Each single shunt was infused 1-6 times. The dose of ethanol was 2-3 ml per time, and the total dose of ethanol was 2-12 ml. All shunting tracts were embolized, and all non-target vessels were protected fluently. Iodine-oil deposition was well in continued TACE. Their syndromes were improved or disappeared. Conclusion: Transmicrocatheter injection of ethanol could safely and effectively treat the hepatic arteriovenous shunts and make advantages to TACE in HCC

  17. Cryptococcal cerebrospinal fluid shunt infection treated with fluconazole

    Directory of Open Access Journals (Sweden)

    Daniel Eymard

    1993-01-01

    Full Text Available A 37-year-old woman with a cadaveric renal allotransplantation required intra-cranial shunting devices after a presumptive episode of tuberculous meningitis. Six months later, she developed a culture-proven cryptococcal meningitis. Without having her ventriculo-auricular shunt removed, she was successfully treated with a short course of amphotericin B (335 mg and flucytosine (nine days followed by prolonged therapy with oral fluconazole (400 mg daily for 72 days. Three years post treatment she had no evidence of relapse, and normal renal graft function.

  18. Pictorial essay: trans-jugular intra-hepatic porto-systemic shunt (TIPS)

    International Nuclear Information System (INIS)

    Rao Anuradha, T.N.; Rastogi, H.; Pandey, U.C.

    2001-01-01

    TIPS is an interventional radiologic method of creating a portosystemic shunt by percutaneous means. It is a relatively new weapon in the armamentarium of the management of portal hypertension with variceal bleeding or intractable ascites. Using needles, angioplasty balloon catheters and expandable metallic stents, a shunt is established directly inside the liver parenchyma connecting a large hepatic vein with a main portal vein branch. Depending on the diameter of the expandable stent used, the created TIPS diverts various amounts of portal blood into the systemic circulation and results in significant portal decompression, cessation of hemorrhage from esophageal varices and resolution of ascites. TIPS is not only an effective and safe alternative to shunt surgery but is life saving in cases of variceal hemorrhage. The use of TIPS seems to be a valid alternative to surgery and has several advantages over either esophageal transection or surgical shunts. TIPS avoids a general anesthetic, laparotomy, and disruption of the hepatic venous system that may adversely affect subsequent hepatic transplantation. TIPS has been performed on patients without interfering with successful transplantation

  19. [Extracorporeal ventriculoatrial shunt with the use of one-way ball valve].

    Science.gov (United States)

    Kubo, Shigeki; Takimoto, Hiroshi; Hosoi, Kazuki; Toyota, Shingo; Takakura, Shuji; Hayashi, Yasuhiro; Ueno, Masato; Morisako, Toshitaka; Karasawa, Jun; Ninaga, Hideo; Yoshimine, Toshiki

    2002-04-01

    We developed a simple system of an "extracorporeal" ventriculoatrial (VA) shunt using a one-way ball valve (Acty valve II, Kaneka Medix) to release the patient from postoperative constraint during the ventricular drainage. The system is constructed in such a way that the ventricular drainage tube is connected to the central venous catheter via a one-way valve. The CSF is regulated by using the valve and is diverted into the systemic circulation as in the conventional ventriculoatrial shunt. After 2 or 3 weeks of CSF diversion through the extracorporeal VA shunt, a ventriculoperitoneal shunt is placed if hydrocephalus is apparent by temporary occlusion of the system. We applied this system to 4 patients with hydrocephalus, and we found it useful and free from adverse effects. The patient was freed from physical constraint involved in conventional ventricular drainage and an effective program of early rehabilitation was able to be started.

  20. Bacterial contamination of surgeons' gloves during shunt insertion; a pilot study

    DEFF Research Database (Denmark)

    Sørensen, Preben; Ejlertsen, Tove; Aaen, Dorte

    2008-01-01

    antibiotics and double gloving, by surgeons experienced in shunt surgery. Surgical incision, dissection and tunnelling were done. Then the surgeon, the scrub-nurse and, in three cases, the assistant made an imprint of their outer gloves on agar plates. Hereafter, they changed the outer pair of gloves before...... handling the shunt and completing the operation. The plates were cultured for 6 days in both aerobic and anaerobic environment. In all cases the surgeons gloves were contaminated, and in six cases also the nurses' gloves were contaminated, as well as all three assistants. Propionebacterium acnes were...... nurse and assistant were contaminated with micro-organisms less than 15 min after surgery has been commenced and before the shunts were handled. This study offers a feasible, simple and logical explanation of how shunts may become contaminated and infected. A simple measure would be to change the outer...

  1. Our initial experience with ventriculo-epiplooic shunt in treatment of hydrocephalus in two centers.

    Science.gov (United States)

    Grigorean, Valentin Titus; Sandu, Aurelia Mihaela; Popescu, Mihai; Florian, Ioan Stefan; Lupascu, Cristian Dumitru; Ursulescu, Corina Lupascu

    Hydrocephalus represents impairment in cerebrospinal fluid (CSF) dynamics. If the treatment of hydrocephalus is considered difficult, the repeated revisions of ventriculo-peritoneal (VP) shunts are even more challenging. The aim of this article is to evaluate the efficiency of ventriculo-epiplooic (VEp) shunt as a feasible alternative in hydrocephalic patients. A technical modification regarding the insertion of peritoneal catheter was imagined: midline laparotomy 8-10cm long was performed in order to open the peritoneal cavity; the great omentum was dissected between its two layers; we placed the distal end of the catheter between the two epiplooic layers; a fenestration of 4cm in diameter into the visceral layer was also performed. A retrospective study of medical records of 15 consecutive patients with hydrocephalus treated with VEp shunt is also presented. Between 2008 and 2014 we performed VEp shunt in 15 patients: 5 with congenital hydrocephalus, 8 with secondary hydrocephalus and 2 with normal pressure hydrocephalus. There were 7 men and 8 women. VEp shunt was performed in 13 patients with multiple distal shunt failures and in 2 patients, with history of abdominal surgery, as de novo extracranial drainage procedure. The outcome was favorable in all cases, with no significant postoperative complications. VEp shunt is a new, safe and efficient surgical technique for the treatment of hydrocephalus. VEp shunt is indicated in patients with history of recurrent distal shunt failures, and in patients with history of open abdominal surgery and high risk for developing abdominal complications. Copyright © 2017 Polish Neurological Society. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.

  2. LC–MS Proteomics Analysis of the Insulin/IGF-1-Deficient Caenorhabditis elegans daf-2(e1370) Mutant Reveals Extensive Restructuring of Intermediary Metabolism

    Energy Technology Data Exchange (ETDEWEB)

    Depuydt, Geert; Xie, Fang; Petyuk, Vladislav A.; Smolders, Arne; Brewer, Heather M.; Camp, David G.; Smith, Richard D.; Braeckman, Bart P.

    2014-04-04

    The insulin/IGF-1 receptor is a major known determinant of dauer formation, stress resistance, longevity, and metabolism in Caenorhabditis elegans. In the past, whole-genome transcript profiling was used extensively to study differential gene expression in response to reduced insulin/IGF-1 signaling, including the expression levels of metabolism-associated genes. Taking advantage of the recent developments in quantitative liquid chromatography mass spectrometry (LC–MS)-based proteomics, we profiled the proteomic changes that occur in response to activation of the DAF-16 transcription factor in the germline-less glp-4(bn2);daf-2(e1370) receptor mutant. Strikingly, the daf-2 profile suggests extensive reorganization of intermediary metabolism, characterized by the upregulation of many core intermediary metabolic pathways. These include glycolysis/gluconeogenesis, glycogenesis, pentose phosphate cycle, citric acid cycle, glyoxylate shunt, fatty acid β-oxidation, one-carbon metabolism, propionate and tyrosine catabolism, and complexes I, II, III, and V of the electron transport chain. Interestingly, we found simultaneous activation of reciprocally regulated metabolic pathways, which is indicative of spatiotemporal coordination of energy metabolism and/or extensive post-translational regulation of these enzymes. Finally, this restructuring of daf-2 metabolism is reminiscent to that of hypometabolic dauers, allowing the efficient and economical utilization of internal nutrient reserves and possibly also shunting metabolites through alternative energy-generating pathways to sustain longevity.

  3. LC-MS Proteomics Analysis of the Insulin/IGF-1 Deficient Caenorhabditis elegans daf-2(e1370) Mutant Reveals Extensive Restructuring of Intermediary Metabolism

    Energy Technology Data Exchange (ETDEWEB)

    Depuydt, Geert G.; Xie, Fang; Petyuk, Vladislav A.; Smolders, Arne; Brewer, Heather M.; Camp, David G.; Smith, Richard D.; Braeckman, Bart P.

    2014-02-20

    The insulin/IGF-1 receptor is a major known determinant of dauer formation, stress resistance, longevity and metabolism in C. elegans. In the past, whole-genome transcript profiling was used extensively to study differential gene expression in response to reduced insulin/IGF-1 signaling, including expression levels of metabolism-associated genes. Taking advantage of the recent developments in quantitative liquid chromatography mass-spectrometry (LC-MS) based proteomics, we profiled the proteomic changes that occur in response to activation of the DAF-16 transcription factor in the germline-less glp-4(bn2); daf-2(e1370) receptor mutant. Strikingly, the daf-2 profile suggests extensive reorganization of intermediary metabolism, characterized by the up-regulation of many core intermediary metabolic pathways. These include, glycolysis/gluconeogenesis, glycogenesis, pentose phosphate cycle, citric acid cycle, glyoxylate shunt, fatty acid β-oxidation, one-carbon metabolism, propionate and tyrosine catabolism, and complex I, II, III and V of the electron transport chain. Interestingly, we found simultaneous activation of reciprocally regulated metabolic pathways, which is indicative for spatio-temporal coordination of energy metabolism and/or extensive post-translational regulation of these enzymes. This restructuring of daf-2 metabolism is reminiscent to that of hypometabolic dauers, allowing the efficient and economical utilization of internal nutrient reserves, possibly also shunting metabolites through alternative energy-generating pathways, in order to sustain longevity.

  4. LC–MS Proteomics Analysis of the Insulin/IGF-1-Deficient Caenorhabditis elegans daf-2(e1370) Mutant Reveals Extensive Restructuring of Intermediary Metabolism

    Science.gov (United States)

    2015-01-01

    The insulin/IGF-1 receptor is a major known determinant of dauer formation, stress resistance, longevity, and metabolism in Caenorhabditis elegans. In the past, whole-genome transcript profiling was used extensively to study differential gene expression in response to reduced insulin/IGF-1 signaling, including the expression levels of metabolism-associated genes. Taking advantage of the recent developments in quantitative liquid chromatography mass spectrometry (LC–MS)-based proteomics, we profiled the proteomic changes that occur in response to activation of the DAF-16 transcription factor in the germline-less glp-4(bn2);daf-2(e1370) receptor mutant. Strikingly, the daf-2 profile suggests extensive reorganization of intermediary metabolism, characterized by the upregulation of many core intermediary metabolic pathways. These include glycolysis/gluconeogenesis, glycogenesis, pentose phosphate cycle, citric acid cycle, glyoxylate shunt, fatty acid β-oxidation, one-carbon metabolism, propionate and tyrosine catabolism, and complexes I, II, III, and V of the electron transport chain. Interestingly, we found simultaneous activation of reciprocally regulated metabolic pathways, which is indicative of spatiotemporal coordination of energy metabolism and/or extensive post-translational regulation of these enzymes. This restructuring of daf-2 metabolism is reminiscent to that of hypometabolic dauers, allowing the efficient and economical utilization of internal nutrient reserves and possibly also shunting metabolites through alternative energy-generating pathways to sustain longevity. PMID:24555535

  5. Quantitative determination of peripheral arterio-venous shunts by means of radioactively labelled microspheres

    International Nuclear Information System (INIS)

    Friese, K.H.

    1981-01-01

    In the present work a nuclear method of quantitative measurement of peripheral arterio-venous shunts with a whole-body scanner is standardized. This method, developed at the beginning of the 70s at Tuebingen, stands out in contrast with earlier measuring methods by the application of the theory of quantitative scintiscanning. This means that the scintigram obtained after injection of sup(99m)technetium-labelled human albumin microspheres into an artery before the shunt is corrected for the quantitative shunt calculation by several factors using a computer, to avoid systematic mistakes. For the standardization of the method, 182 scintigrams were taken during model experiments and experiments on animals and human beings. This method, having a deviation of 10% at most, is excellently suited for the quantitative determination of peripheral arterio-venous shunts. Already for a pulmonary activity of 3% a peripheral shunt is proved with 97.5% probability. (orig./MG) [de

  6. Reversible Venting Stitch for Fenestrating Valve-less Glaucoma Shunts.

    Science.gov (United States)

    Akil, Handan; Vu, Priscilla Q; Nguyen, Anhtuan H; Nugent, Alexander; Chopra, Vikas; Francis, Brian A; Tan, James C

    2017-12-01

    The purpose of this is to describe a venting stitch modification for valveless glaucoma aqueous shunts and characterize early postoperative intraocular pressure (IOP) and glaucoma medication use following the modification. Retrospective chart review of 61 sequential patients undergoing Baerveldt glaucoma implant (BGI)-350 implantation at the Doheny Eye Institute. Twenty-four patients received a glaucoma shunt with venting stitch modification (modified BGI) and 37 patients received an unmodified shunt (BGI-only). IOP, number of glaucoma medications, and number of hypotony cases (intraocular pressure ≤5 mm Hg) were compared between the groups. T-tests were used for statistical analysis. At postoperative-day 1, mean IOP was significantly lower compared with preoperatively in the modified BGI group (14 mm Hg; reduced by 51%; P<0.0001) but not the BGI-only group (27 mm Hg; P=0.06). IOP difference between groups persisted till immediately before tube opening (P=0.005) and fewer IOP-lowering medications needed in the modified BGI group (P<0.0001). One case (4.2%) of postoperative hypotony was encountered with BGI modification, which resolved after the stitch was removed in clinic. The venting stitch valveless shunt modification allows for effective, reliable, and safe control of early postoperative IOP.

  7. Cellophane banding for the gradual attenuation of single extrahepatic portosystemic shunts in eleven dogs.

    Science.gov (United States)

    Youmans, K R; Hunt, G B

    1998-08-01

    To evaluate the efficacy and short term effects of a cellophane banding technique for progressive attenuation of canine single extrahepatic portosystemic shunts. A prospective trial of 11 dogs with single congenital extrahepatic shunts. Rectal ammonia tolerance testing and routine biochemical tests were performed preoperatively on all dogs. In seven dogs, preoperative abdominal Doppler ultrasonography was also performed. Exploratory laparotomy revealed a single extrahepatic portocaval shunt in each animal, which was attenuated using a cellophane band with an internal diameter of 2 to 3 mm. The abdomen was closed routinely. Follow-up biochemical analysis and abdominal Doppler ultrasonography or splenoportography were performed postoperatively. The shunt was not amenable to total ligation in 11 dogs, based upon reported criteria. All dogs recovered uneventfully from surgery without evidence of portal hypertension, and showed clinical improvement thereafter. Shunt occlusion was deemed to have occurred in 10 dogs based on resolution of biochemical and/or sonographic abnormalities. One dog continued to have sonographic evidence of portosystemic shunting when evaluated 3 weeks after surgery, despite normal ammonia tolerance, but was lost to subsequent follow-up. Two dogs, in which 3 mm cellophane bands were placed, experienced delayed shunt occlusion. Cellophane banding is simple to perform, and causes progressive attenuation of single extrahepatic shunts in dogs. Further work is needed to determine the maximum diameter of a cellophane band which will produce total attenuation, and the long-term safety and reliability of the treatment.

  8. Management of Ventriculoperitoneal Shunt Infections in Adults: Analysis of Risk Factors Associated With Treatment Failure.

    Science.gov (United States)

    Pelegrín, Iván; Lora-Tamayo, Jaime; Gómez-Junyent, Joan; Sabé, Nuria; García-Somoza, Dolors; Gabarrós, Andreu; Ariza, Javier; Viladrich, Pedro Fernández; Cabellos, Carmen

    2017-04-15

    Little is known regarding the optimal treatment of ventriculoperitoneal (VP) shunt infections in adults. Our aim was to assess the efficacy of treatment strategies and to identify factors that predict failure. Retrospective, observational study of patients aged ≥12 years with VP shunt infections (1980 -2014). Therapeutic approaches were classified under 4 headings: only antibiotics (OA), one-stage shunt replacement (OSSR), two-stage shunt replacement (TSSR), and shunt removal without replacement (SR). The primary endpoint was failure of the treatment strategy, defined as the absence of definite cerebrospinal fluid (CSF) sterilization or related mortality. The parameters that predicted failure were analyzed using logistic regression. Of 108 episodes (51% male, median age 50 years), 86 were analyzed. Intravenous antibiotics were administered for a median of 19 days. Eighty episodes were treated using strategies that combined antibiotic and surgical treatment (37 TSSR, 24 SR, 19 OSSR) and 6 with OA. Failure occurred in 30% of episodes, mostly due to lack of CSF sterilization in OSSR and OA groups. Twelve percent died of related causes and 10% presented superinfection of the CSF temporary drainage/externalized peritoneal catheter. TSSR was the most effective strategy when VP shunt replacement was attempted. The only independent risk factor that predicted failure was retention of the VP shunt, regardless of the strategy. This is the largest series of VP shunt infections in adults reported to date. VP shunt removal, particularly TSSR when the patient is shunt dependent, remains the optimal choice of treatment and does not increase morbidity. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

  9. Frontal and occipital horn ratio is associated with multifocal intraparenchymal hemorrhages in neonatal shunted hydrocephalus.

    Science.gov (United States)

    Oushy, Soliman; Parker, Jonathon J; Campbell, Kristen; Palmer, Claire; Wilkinson, Corbett; Stence, Nicholas V; Handler, Michael H; Mirsky, David M

    2017-11-01

    OBJECTIVE Placement of a cerebrospinal fluid diversion device (i.e., shunt) is a routine pediatric neurosurgical procedure, often performed in the first weeks of life for treatment of congenital hydrocephalus. In the postoperative period, shunt placement may be complicated by subdural, catheter tract, parenchymal, and intraventricular hemorrhages. The authors observed a subset of infants and neonates who developed multifocal intraparenchymal hemorrhages (MIPH) following shunt placement and sought to determine any predisposing perioperative variables. METHODS A retrospective review of the electronic medical record at a tertiary-care children's hospital was performed for the period 1998-2015. Inclusion criteria consisted of shunt placement, age hydrocephalus. Markers of severity of ventriculomegaly (FOR) and ventricular response to CSF diversion (∆FOR) were significantly associated with occurrence of MIPH. Choice of shunt and etiology of hydrocephalus were also significantly associated with MIPH. After adjusting for corrected age, etiology of hydrocephalus, and shunt setting, the authors found that ∆FOR after shunting was still associated with MIPH. A prospective study of MIPH prevention strategies and assessment of possible implications for patient outcomes is needed.

  10. ARTIFICIAL SHUNTING OF CEREBROSPINAL-FLUID

    NARCIS (Netherlands)

    HOEKSTRA, A

    A compact three-stage shunt valve system (Orbis SigmaTM Valve) which operates as a flow regulator within certain differential pressure values has been clinically evaluated in the treatment of hydrocephalus. Clinical trials were performed in 134 cases, covering 128 patients aged from 1 day to 79

  11. A Modified Shunt System for the Management of Pyogenic Hydrocephalus

    Directory of Open Access Journals (Sweden)

    Abdul Naveed Khan

    2017-01-01

    Full Text Available BACKGROUND: To describe the structure and efficacy of a modified cerebrospinal fluid (CSF shunt system with Bhatti CSF access chamber and ventriculoperitoneal shunt, for the management of hydrocephalus associated with pyogenic ventriculitis. METHODS: This was an observational study performed at the National Medical Center and Ziauddin Medical University, Karachi, Pakistan. Chemically bonded Bhatti CSF access chamber and ventriculoperitoneal shunt was inserted into 443 patients with hydrocephalus and pyogenic ventriculitis to allow injection of antibiotics into the lateral ventricles. RESULTS: In all patients, symptoms and signs of hydrocephalus were relieved immediately after shunt insertion and infection brought under control within two weeks of intraventricular injection of antibiotics (vancomycin or linezolid, via the CSF access chamber. In two patients peritoneal catheter was blocked by a precipitate of vancomycin. Reduction in the dose of intraventricular vancomycin from 50mg to 20mg and increased dilution (additional 2ml of 0.9% N/S solution prevented recurrence of this complication. All patients recovered from ventriculitis within two weeks of initiating this treatment. Follow-up was from 3 months to 2 years to monitor continued relief of hydrocephalus and absence of recurrence of ventriculitis. CONCLUSION: Bhatti CSF access chamber and the ventriculoperitoneal shunt is the only system available at present that fulfills the management of hydrocephalus associated with pyogenic ventriculitis. It provides continuous internal drainage of CSF combined with access to the ventricles for injection of antibiotics.

  12. Shunts to divert aqueous humor to distant epithelialized cavities after keratoprosthesis surgery.

    Science.gov (United States)

    Dohlman, Claes H; Grosskreutz, Cynthia L; Chen, Teresa C; Pasquale, Louis R; Rubin, Peter A D; Kim, Eva C; Durand, Marlene

    2010-02-01

    Glaucoma is a frequent and often severe problem in patients needing keratoprosthesis (KPro) surgery. Standard glaucoma shunts in these cases often develop a very dense capsule that obstructs flow and causes intraocular pressure elevation. Therefore, we developed shunts that deliver aqueous to distant epithelialized cavities where an obstructing capsule is less likely to form. In this retroactive study of such shunts, the risk of postoperative infection (especially endophthalmitis) has been assessed. Ahmed shunts were connected with a tube to the lacrimal sac or ethmoid sinuses. In subsequent designs the polypropylene plate was eliminated, the valve was enclosed and a distal tube added (New World Medical Inc, Rancho Cucamonga, CA). The latter shunts were connected to the maxillary sinus or lower lid fornix. Between 2001 and 2005 the devices were implanted in 34 patients with very severe ocular disease. (31 had KPro implanted). Thus, the distal tube was led to the lacrimal sac (2 cases), to the ethmoid sinuses (6), to the maxillary sinus (16 cases), and to the lower lid fornix (10 cases). The patients were followed for cumulatively 145 shunt years, with a mean follow-up of 4 years and 3 months. They were instructed to administer low-dose topical antibiotics indefinitely. Only 1 case of acute bacterial endophthalmitis occurred, thus an incidence of 0.7% per shunt year. A slow-growing Mycobacterium was cultured in a disintegrating eye and 1 bacterial maxillary sinusitis occurred, both in autoimmune diseases. Three valves became exposed and had to be removed (1 replaced). Four eyes developed hypotony, probably from valve failure. The shunt arrangement, which connects the anterior chamber to potentially microbe-populated cavities or to the lower lid fornix and its flora, might be suspected to allow rapid retrograde invasion of infective agents, resulting in endophthalmitis. In this series of KPro patients, however, the incidence of severe infection was very low, in fact

  13. Treatment of Portosystemic Shunt Myelopathy with a Stent Graft Deployed through a Transjugular Intrahepatic Route

    International Nuclear Information System (INIS)

    Jain, Deepak; Arora, Ankur; Deka, Pranjal; Mukund, Amar; Bhatnagar, Shorav; Jindal, Deepti; Kumar, Niteen; Pamecha, Viniyendra

    2013-01-01

    A case of surgically created splenorenal shunt complicated with shunt myelopathy was successfully managed by placement of a stent graft within the splenic vein to close the portosystemic shunt and alleviate myelopathy. To our knowledge, this is the first report of a case of shunt myelopathy in a patient with noncirrhotic portal fibrosis without cirrhosis treated by a novel technique wherein a transjugular intrahepatic route was adopted to deploy the stent graft

  14. Superior vena cava syndrome after pulsatile bidirectional Glenn shunt procedure: Perioperative implications

    Directory of Open Access Journals (Sweden)

    Neema Praveen

    2009-01-01

    Full Text Available Bidirectional superior cavopulmonary shunt (bidirectional Glenn shunt is generally performed in many congenital cardiac anomalies where complete two ventricle circulations cannot be easily achieved. The advantages of BDG shunt are achieved by partially separating the pulmonary and systemic venous circuits, and include reduced ventricular preload and long-term preservation of myocardium. The benefits of additional pulsatile pulmonary blood flow include the potential growth of pulmonary arteries, possible improvement in arterial oxygen saturation, and possible prevention of development of pulmonary arteriovenous malformations. However, increase in the systemic venous pressure after BDG with additional pulsatile blood flow is known. We describe the peri-operative implications of severe flow reversal in the superior vena cava after pulsatile BDG shunt construction in a child who presented for surgical interruption of the main pulmonary artery.

  15. Ventriculoperitoneal shunt-related infections caused by Staphylococcus epidermidis: pathogenesis and implications for treatment.

    LENUS (Irish Health Repository)

    Stevens, Niall T

    2012-12-01

    The insertion of medical devices, such as intraventricular shunts, is often complicated by infection leading to ventriculitis. Frequently, such infections result from colonisation and subsequent biofilm formation on the surfaces of the shunts by Staphylococcus epidermidis. The pathogenesis of neurosurgical shunt-related infection is complex with interactions between the pathogen, the device and the unique local immunological environment of the central nervous system (CNS). An ability to form biofilm, the main virulence determinant of Staphylococcus epidermidis, facilitates protection of the organism from the host defences while still initiating an immunological response. The presence of the blood brain barrier (BBB) and the biofilm itself also complicates treatment, which presents many challenges when managing shunt infections. A greater understanding of the interplay between S. epidermidis and the CNS could potentially improve the diagnosis, treatment and management of such infections. This review describes the pathogenesis, treatment and implications of S. epidermidis ventriculoperitoneal shunt-related infections, concentrating on recent research and the implications for treatment.

  16. Design strategy for the combined system of shunt passive and series active filters

    OpenAIRE

    Fujita, Hideki; Akagi, Hirofumi

    1991-01-01

    A design strategy for the combined power filter for a three-phase twelve-pulse thyristor rectifier is proposed. The shunt passive filter, which can minimize the output voltage of the series active filter, is designed and tested in a prototype model. A specially designed shunt passive filter makes it possible to reduce the required rating of the series active filter to 60% compared with a conventional shunt passive filter

  17. Two cases of esophageal cancer with portal hypertension: esophagectomy with venous shunt procedure.

    Science.gov (United States)

    Kato, T; Motohara, T; Kaneko, Y; Shikishima, H; Okushiba, S; Kondo, S; Kato, H

    2001-01-01

    We performed venous shunt procedure in the reconstruction of the esophagus after esophagectomy using the gastric tube in two cases of esophageal cancer with portal hypertension due to liver cirrhosis. In both cases, the short-term postoperative course was uneventful, without congestion in the gastric tube. In Case 1 where the short gastric vein had been used as the shunt vein, the long-term postoperative course was also uneventful, without hepatic encephalopathy or hemorrhage from deterioration of the varices of the gastric tube. However, in Case 2 where the left gastroepiploic vein had been used, hepatic encephalopathy developed due to excessive shunt flow. These results suggested that appropriate shunt flow could be expected by using short gastric vein.

  18. Reduction of shunt obstructions by using a peel-away sheath technique? A multicenter prospective randomized trial.

    Science.gov (United States)

    Kehler, Uwe; Langer, Niels; Gliemroth, Jan; Meier, Ullrich; Lemcke, Johannes; Sprung, Christian; Schlosser, Hans-Georg; Kiefer, Michael; Eymann, Regina; Heese, Oliver

    2012-05-01

    Shunt obstructions may partly be caused by brain debris, which intrude into the ventricular catheter during ventricle puncture. Avoiding contact between the catheter and brain tissue, by using a peel-away sheath, should reduce the number of shunt failures caused by obstruction. To test this hypothesis, we conducted a randomized, prospective multicenter study. 201 patients from 6 different neurosurgical centers in Germany receiving a ventriculo-peritoneal shunt were included in this study. Of these, 177 patients completed a 1-year follow-up period. Surgery was randomized in a 1 to 1 fashion, such that out of 177 procedures, 91 were performed using a peel-away sheath and 86 were performed without. The rate of surgical re-interventions and shunt obstructions within a 12-month period was recorded. Within 1 year post-surgery, 17 shunt obstructions (9.6%) leading to shunt revisions were recorded. However, no difference was found between surgeries performed using a peel-away sheath (9.9%) or not (9.3%). The overall shunt infection rate was 2.8% and the shunt revision rate for overdrainage was 3.9%. The theoretical advantages attributed to the use of a peel-away sheath to introduce a ventricular catheter could not be confirmed in this randomized study, suggesting that the proposed role of brain debris in shunt obstructions may be overestimated. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. 21 CFR 882.5550 - Central nervous system fluid shunt and components.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Central nervous system fluid shunt and components... Central nervous system fluid shunt and components. (a) Identification. A central nervous system fluid... central nervous system to an internal delivery site or an external receptacle for the purpose of relieving...

  20. Intrahepatic Portosystemic Venous Shunt: Successful Embolization Using the Amplatzer Vascular Plug II

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Ju; Shin, Byung Seok; Lee, In Ho; Ohm, Joon Young; Lee, Byung Seok; Ahn, Moon Sang [Chungnam National University Hospital, Chungnam National University College of Medicine, Daejeon (Korea, Republic of); Kim, Ho Jun [Dept. of Radiology, Konyang University Hospital, Konyang University College of Medicine, Daejeon (Korea, Republic of)

    2012-11-15

    A 67-year-old woman presented with memory impairment and behavioral changes. Brain MRI indicated hepatic encephalopathy. Abdominal CT scans revealed an intrahepatic portosystemic venous shunt that consisted of two shunt tracts to the aneurysmal sac that communicated directly with the right hepatic vein. The large tract was successfully occluded by embolization using the newly available AMPLATZERTM Vascular Plug II and the small tract was occluded by using coils. The patient's symptoms disappeared after shunt closure and she remained free of recurrence at the 3-month follow-up evaluation.

  1. Laparoscopic assisted ventriculoperitoneal shunt revisions as an option for pediatric patients with previous intraabdominal complications

    Directory of Open Access Journals (Sweden)

    Fernanda O. de Carvalho

    2014-04-01

    Full Text Available Multiple shunt failure is a challenge in pediatric neurosurgery practice and one of the most feared complications of hydrocephalus. Objective: To demonstrate that laparoscopic procedures for distal ventriculoperitoneal shunt failure may be an effective option for patients who underwent multiple revisions due to repetitive manipulation of the peritoneal cavity, abdominal pseudocyst, peritonitis or other situations leading to a “non reliable” peritoneum. Method: From March 2012 to February 2013, the authors reviewed retrospectively the charts of six patients born and followed up at our institution, which presented with previous intra-peritoneal complications and underwent ventriculoperitoneal shunt revision assisted by video laparoscopy. Results: After a mean follow-up period of nine months, all patients are well and no further shunt failure was identified so far. Conclusion: Laparoscopy assisted shunt revision in children may be, in selected cases, an effective option for patients with multiple peritoneal complications due to ventriculo-peritoneal shunting.

  2. Endoscopic third ventriculostomy versus ventriculoperitoneal shunt ...

    African Journals Online (AJOL)

    Patients' medical records, operative notes, and neural tube database records were used to complete a structured questionnaire. The difference in ... likely after 6 months. Keywords: obstructive hydrocephalus; endoscopic third ventriculostomy; ventriculoperitoneal shunt; children; paediatric surgery; neurosurgery; Ethiopia ...

  3. Multifaceted roles of metabolic enzymes of the Paracoccidioides species complex

    Directory of Open Access Journals (Sweden)

    Caroline Maria Marcos

    2014-12-01

    Full Text Available Paracoccidioides species are dimorphic fungi, and are the etiologic agents of paracoccidioidomycosis (PCM, a serious disease of multiple organs. The large number of tissues colonized by this fungus suggests the presence of a variety of surface molecules involved in adhesion. A surprising finding is that the majority of enzymes in the glycolytic pathway, tricarboxylic acid (TCA cycle and glyoxylate cycle in Paracoccidioides spp. has adhesive properties that aid in the interaction with the host extracellular matrix, and so act as ‘moonlighting’ proteins. Moonlighting proteins have multiple functions and add another dimension to cellular complexity, while benefiting cells in several ways. This phenomenon occurs in both eukaryotes and prokaryotes. For example, moonlighting proteins from the glycolytic pathway or TCA cycle can play roles in bacterial pathogens, either by acting as proteins secreted in a conventional pathway or not and/or as cell surface component that facilitate adhesion or adherence . This review outlines the multifuncionality exposed by a variety of Paracoccidioides spp. enzymes including aconitase, aldolase, glyceraldehyde-3-phosphate dehydrogenase, isocitrate lyase, malate synthase, triose phosphate isomerase, fumarase and enolase. The roles that moonlighting activities play in the virulence characteristics of this fungus and several other human pathogens during their interactions with the host are discussed.

  4. Treatment of Occluded Distal Splenorenal Shunts with Endovascular Stents: A Report of Two Cases

    International Nuclear Information System (INIS)

    Lopez-Medina, Antonio; Peiro, Javier; Gonzalez de Garay, Miguel; Antonana, Miguel A.; Sustacha, Jon; Grande, Domingo

    2001-01-01

    Surgical treatment of an occluded or stenotic portosystemic shunt is difficult and carries a high risk of mortality. We report two cases of early thrombosis of distal splenorenal shunt (DSRS) successfully treated by transcatheter recanalization and stent placement. At 18-month follow-up, the patients remained asymptomatic and control venograms showed continued patency of the shunt with no evidence of stenosis or collaterals

  5. Correlation of experimental rCBF determinations in goats with flow measurements from a Doppler-modified carotid artery shunt

    International Nuclear Information System (INIS)

    Loftus, C.M.; Silvidi, J.A.; Becker, J.A.; Miller, B.V.; Bernstein, D.D.

    1989-01-01

    A carotid artery shunt system has been developed that continuously monitors blood flow rates by embedding a Doppler crystal in the shunt wall. The crystal ranges through a liquid lens that enables it to be placed without violation of the shunt lumen. Because the crystal is at a fixed angle (45 degrees) to the axis of blood flow and the diameter of the lumen remains constant, a linear relationship exists between flow rates and the Doppler velocity signal. This shunt system was previously tested in vitro using a pulsatile pump and was found to be accurate to within 4.7% of the actual flow rate. In the present study, animal (goat) experiments were performed consisting of simultaneous carotid shunt flow and bilateral rCBF measurements by the radiolabeled microsphere technique to determine in vivo the accuracy of this Doppler modified shunt and to ascertain the ability of shunt flow to increase in the face of acute contralateral carotid occlusion. Data from five animals show that in vivo shunt flow can be recorded to within 13% of control rCBF and that shunt flow increases nearly 50% under conditions of distal demand (contralateral carotid occlusion). This device may prove useful in laboratory studies of carotid shunt dynamics and in clinical practice to quickly detect correctable shunt flow abnormalities

  6. Treatment of hydrocephalus associated with neurosarcoidosis by multiple shunt placement.

    Science.gov (United States)

    Kim, Sung Hoon; Lee, Sang Weon; Sung, Soon Ki; Son, Dong Wuk

    2012-09-01

    A 31-year-old man was admitted to our hospital due to hydrocephalus with neurosarcoidosis. Ventriculo-peritoneal shunting was performed in the right lateral ventricle with intravenous methylprednisolone. Subsequently, after 4 months, additional ventriculo-peritoneal shunting in the left lateral ventricle was performed due to the enlarged left lateral ventricle and slit-like right lateral ventricle. After 6 months, he was re-admitted due to upward gaze palsy, and magnetic resonance image showed an isolated fourth ventricle with both the inlet and outlet of fourth ventricle obstructed by recurrent neurosarcoidosis. Owing to the difficulty of using an endoscope, we performed neuronavigator-guided ventriculo-peritoneal shunting via the left lateral transcerebellar approach for the treatment of the isolated fourth ventricle with intravenous methyl prednisolone. The patient was discharged with improved neurological status.

  7. Cerebrospinal Fluid Lumbar Tapping Utilization for Suspected Ventriculoperitoneal Shunt Under-Drainage Malfunctions.

    Science.gov (United States)

    Lee, Jong-Beom; Ahn, Ho-Young; Lee, Hong-Jae; Yang, Ji-Ho; Yi, Jin-Seok; Lee, Il-Woo

    2017-01-01

    The diagnosis of shunt malfunction can be challenging since neuroimaging results are not always correlated with clinical outcomes. The purpose of this study was to evaluate the efficacy of a simple, minimally invasive cerebrospinal fluid (CSF) lumbar tapping test that predicts shunt under-drainage in hydrocephalus patients. We retrospectively reviewed the clinical and radiological features of 48 patients who underwent routine CSF lumbar tapping after ventriculoperitoneal shunt (VPS) operation using a programmable shunting device. We compared shunt valve opening pressure and CSF lumbar tapping pressure to check under-drainage. The mean pressure difference between valve opening pressure and CSF lumbar tapping pressure of all patients were 2.21±24.57 mmH 2 O. The frequency of CSF lumbar tapping was 2.06±1.26 times. Eighty five times lumbar tapping of 41 patients showed that their VPS function was normal which was consistent with clinical improvement and decreased ventricle size on computed tomography scan. The mean pressure difference in these patients was -3.69±19.20 mmH 2 O. The mean frequency of CSF lumbar tapping was 2.07±1.25 times. Fourteen cases of 10 patients revealed suspected VPS malfunction which were consistent with radiological results and clinical symptoms, defined as changes in ventricle size and no clinical improvement. The mean pressure difference was 38.07±23.58 mmH 2 O. The mean frequency of CSF lumbar tapping was 1.44±1.01 times. Pressure difference greater than 35 mmH 2 O was shown in 2.35% of the normal VPS function group (2 of 85) whereas it was shown in 64.29% of the suspected VPS malfunction group (9 of 14). The difference was statistically significant ( p =0.000001). Among 10 patients with under-drainage, 5 patients underwent shunt revision. The causes of the shunt malfunction included 3 cases of proximal occlusion and 2 cases of distal obstruction and valve malfunction. Under-drainage of CSF should be suspected if CSF lumbar tapping

  8. Morphology of congenital portosystemic shunts involving the left colic vein in dogs and cats.

    Science.gov (United States)

    White, R N; Parry, A T

    2016-05-01

    To describe the anatomy of congenital portosystemic shunts involving the left colic vein in dogs and cats. Retrospective review of a consecutive series of dogs and cats managed for congenital portosystemic shunts. For inclusion a shunt involving the left colic vein with recorded intraoperative mesenteric portovenography or computed tomography angiography along with direct gross surgical observations at the time of surgery was required. Six dogs and three cats met the inclusion criteria. All cases had a shunt which involved a distended left colic vein. The final communication with a systemic vein was variable; in seven cases (five dogs, two cats) it was via the caudal vena cava, in one cat it was via the common iliac vein and in the remaining dog it was via the internal iliac vein. In addition, two cats showed caudal vena cava duplication. The morphology of this shunt type appeared to be a result of an abnormal communication between either the left colic vein or the cranial rectal vein and a pelvic systemic vein (caudal vena cava, common iliac vein or internal iliac vein). This information may help with surgical planning in cases undergoing shunt closure surgery. © 2016 British Small Animal Veterinary Association.

  9. Cerebral Blood Flow Changes after Shunt in Hydrocephalus after Aneurysmal Subarachnoid Hemorrhage: Analysis by statistical Parametric Mapping

    International Nuclear Information System (INIS)

    Hyun, I. Y.; Choi, W. S.; Pak, H. S.

    2003-01-01

    The purpose of this study was to evaluate the changes of regional cerebral blood flow (rCBF) after shunt operation in patients with hydrocephalus after aneurysmal subarachnoid hemorrhage ba statistical parametric mapping (SPM). Seven patients (4 male, mean age 54 years) with hydrocephalus after aneurysmal subarachnoid hemorrhage underwent a shunt operation. Tc-99m HMPAO SPECT was performed within I week before, and 2 weeks after the shunt operation. All of the SPECT images were spatially transformed to standard space, smoothed, and globally normalized. After spatial and count normalization, rCBF of pre- and post- shunting Tc- 99m HMPAO SPECT was estimated at every voxel using t statistics. The voxels with a P value of less than 0.001 were considered to be significantly different. The shunt operation was effective in all patients. Pre-shunting Tc-99m HMPAO SPECT showed hypoperfusion, predominantly in the periventricular area. After shunt operation, periventricular low perfusion was disappeared. The results of this study show that periventricular CBF is impaired in hydrocephalus after aneurysmal subarachnoid hemorrhage. Significant increase of periventricular CBF after shunt operation suggests the evaluation of periventricular CBF by SPM might be of value for the prediction of shunt effectiveness in hydrocephalus

  10. Cerebral Blood Flow Changes after Shunt in Hydrocephalus after Aneurysmal Subarachnoid Hemorrhage: Analysis by statistical Parametric Mapping

    Energy Technology Data Exchange (ETDEWEB)

    Hyun, I. Y.; Choi, W. S.; Pak, H. S. [College of Medicine, Univ. of Inhwa, Incheon (Korea, Republic of)

    2003-07-01

    The purpose of this study was to evaluate the changes of regional cerebral blood flow (rCBF) after shunt operation in patients with hydrocephalus after aneurysmal subarachnoid hemorrhage ba statistical parametric mapping (SPM). Seven patients (4 male, mean age 54 years) with hydrocephalus after aneurysmal subarachnoid hemorrhage underwent a shunt operation. Tc-99m HMPAO SPECT was performed within I week before, and 2 weeks after the shunt operation. All of the SPECT images were spatially transformed to standard space, smoothed, and globally normalized. After spatial and count normalization, rCBF of pre- and post- shunting Tc- 99m HMPAO SPECT was estimated at every voxel using t statistics. The voxels with a P value of less than 0.001 were considered to be significantly different. The shunt operation was effective in all patients. Pre-shunting Tc-99m HMPAO SPECT showed hypoperfusion, predominantly in the periventricular area. After shunt operation, periventricular low perfusion was disappeared. The results of this study show that periventricular CBF is impaired in hydrocephalus after aneurysmal subarachnoid hemorrhage. Significant increase of periventricular CBF after shunt operation suggests the evaluation of periventricular CBF by SPM might be of value for the prediction of shunt effectiveness in hydrocephalus.

  11. Early mediastinal seroma secondary to modified Blalock-Taussig shunts - successful management by percutaneous drainage

    International Nuclear Information System (INIS)

    Connolly, Bairbre L.; Temple, Michael J.; Chait, Peter G.; Restrepo, Ricardo; Adatia, Ian

    2003-01-01

    Large symptomatic mediastinal seroma following modified-BT shunts, traditionally required revisional thoracotomy. We describe percutaneous image-guided pigtail catheter drainage in the successful treatment of early mediastinal seroma secondary to PTFE Blalock-Taussig shunt, avoiding thoracotomy. A retrospective review of all relevant clinical and imaging records in five patients was performed. All five presented with intermittent stridor, respiratory distress and/or episodic desaturation within 6 weeks of their surgery. In four of five infants, percutaneous drainage was effective and reoperation was avoided. In one of five, rather than urgent surgical evacuation and BT shunt revision, we were able to perform an elective stage-II bidirectional Glenn SVC-RA anastamosis in a stable infant. There were no complications. Percutaneous image-guided drainage of mediastinal seroma secondary to PTFE-BT shunt is a safe, minimally invasive, and effective treatment. This may avoid BT shunt revision. (orig.)

  12. Staphylococcus warneri ventriculoperitoneal shunt infection: failure of diagnosis by ventricular CSF sampling.

    Science.gov (United States)

    Martínez-Lage, Juan F; Martínez-Lage Azorín, Laura; Almagro, María-José

    2010-12-01

    The definite diagnosis of hydrocephalus valve infection is generally made by cerebrospinal fluid (CSF) sampling via the valve reservoir, which is considered to be more dependable than that of the CSF obtained by lumbar puncture. We treated a 17-year-old boy with an intra-abdominal pseudocyst due to ventriculoperitoneal shunt infection caused by Staphylococcus warneri whose ventricular CSF, obtained via the valve reservoir, was repeatedly sterile thus causing a considerable delay in the management of the complication. S. warneri constitutes an emergent contaminant of catheters and prostheses. We found only a detailed report of S. warneri infection of a ventriculoatrial shunt. If manifestations of peritoneal involvement in shunted patients would occur, the attention should be shifted to the distal component of the shunt hardware, even in the presence of a normal ventricular CSF as happened in our case to avoid unnecessary delay in diagnosis and management.

  13. Manipulating waves by distilling frequencies: a tunable shunt-enabled rainbow trap

    Science.gov (United States)

    Cardella, Davide; Celli, Paolo; Gonella, Stefano

    2016-08-01

    In this work, we propose and test a strategy for tunable, broadband wave attenuation in electromechanical waveguides with shunted piezoelectric inclusions. Our strategy is built upon the vast pre-existing literature on vibration attenuation and bandgap generation in structures featuring periodic arrays of piezo patches, but distinguishes itself for several key features. First, we demystify the idea that periodicity is a requirement for wave attenuation and bandgap formation. We further embrace the idea of ‘organized disorder’ by tuning the circuits as to resonate at distinct neighboring frequencies. In doing so, we create a tunable ‘rainbow trap’ (Tsakmakidis et al 2007 Nature 450 397-401) capable of attenuating waves with broadband characteristics, by distilling (sequentially) seven frequencies from a traveling wavepacket. Finally, we devote considerable attention to the implications in terms of packet distortion of the spectral manipulation introduced by shunting. This work is also meant to serve as a didactic tool for those approaching the field of shunted piezoelectrics, and attempts to provide a different perspective, with abundant details, on how to successfully design an experimental setup involving resistive-inductive shunts.

  14. Impact of cerebrospinal fluid shunting for idiopathic normal pressure hydrocephalus on the amyloid cascade.

    Directory of Open Access Journals (Sweden)

    Masao Moriya

    Full Text Available The aim of this study was to determine whether the improvement of cerebrospinal fluid (CSF flow dynamics by CSF shunting, can suppress the oligomerization of amyloid β-peptide (Aβ, by measuring the levels of Alzheimer's disease (AD-related proteins in the CSF before and after lumboperitoneal shunting. Lumbar CSF from 32 patients with idiopathic normal pressure hydrocephalus (iNPH (samples were obtained before and 1 year after shunting, 15 patients with AD, and 12 normal controls was analyzed for AD-related proteins and APLP1-derived Aβ-like peptides (APL1β (a surrogate marker for Aβ. We found that before shunting, individuals with iNPH had significantly lower levels of soluble amyloid precursor proteins (sAPP and Aβ38 compared to patients with AD and normal controls. We divided the patients with iNPH into patients with favorable (improvement ≥ 1 on the modified Rankin Scale and unfavorable (no improvement on the modified Rankin Scale outcomes. Compared to the unfavorable outcome group, the favorable outcome group showed significant increases in Aβ38, 40, 42, and phosphorylated-tau levels after shunting. In contrast, there were no significant changes in the levels of APL1β25, 27, and 28 after shunting. After shunting, we observed positive correlations between sAPPα and sAPPβ, Aβ38 and 42, and APL1β25 and 28, with shifts from sAPPβ to sAPPα, from APL1β28 to 25, and from Aβ42 to 38 in all patients with iNPH. Our results suggest that Aβ production remained unchanged by the shunt procedure because the levels of sAPP and APL1β were unchanged. Moreover, the shift of Aβ from oligomer to monomer due to the shift of Aβ42 (easy to aggregate to Aβ38 (difficult to aggregate, and the improvement of interstitial-fluid flow, could lead to increased Aβ levels in the CSF. Our findings suggest that the shunting procedure can delay intracerebral deposition of Aβ in patients with iNPH.

  15. Treatment of extrahepatic portal hypertension following a whipple procedure with a Rex shunt: report of a case.

    Science.gov (United States)

    Reichman, Trevor W; Anthony, Tiffany; Testa, Giuliano

    2011-02-01

    The Rex shunt is a mesenteric vein to left portal vein decompressive shunt used for the treatment of portal vein thrombosis and portal hypertension. Its use has been reported primarily in the pediatric population where portal vein thrombosis occurs with some frequency. The shunt is thought to represent a more physiologic shunt, since it restores hepatopedal blood flow through the liver. This report describes the use of this shunt in an adult who had frequent gastrointestinal bleeding secondary to extrahepatic portal vein thrombosis, which occurred as a complication after a pancreaticoduodenectomy.

  16. Angiography-based C-arm CT for the assessment of extrahepatic shunting before radioembolization

    International Nuclear Information System (INIS)

    Heusner, Till Alexander; Hahn, S.; Forsting, M.; Antoch, G.; Hamami, M.E.; Poeppel, T.; Bockisch, A.; Ertle, J.; Hilgard, P.

    2010-01-01

    Purpose: to retrospectively assess the accuracy of angiography-based C-arm CT for the detection of extrahepatic shunting before SIRT. Materials and methods: 30 patients (mean age: 64 ± 12 years) with hypervascularized hepatic tumors underwent hepatic angiography, coil embolization of gastrointestinal collaterals and 99mTc-macroaggregated albumin (MAA) SPECT/CT before SIRT. Before MAA injection via a microcatheter from the intended treatment position, an angiography and angiography-based C-arm CT (XperCT trademark, Philips Healthcare) were acquired. Angiographies and XperCT trademark were performed from 48 microcatheter positions followed by MAA injections and MAA-SPECT/CT. MAA-SPECT/CT served as the reference standard for determining the accuracy of hepatic arteriography and C-arm CT for the detection of extrahepatic shunting. Results: MAA-SPECT/CT revealed extrahepatic shunting in 5 patients (17%). Hepatic arteriography yielded a true negative in 22 (73%), a false negative in 5 (17%), and an unclear result in 3 patients (10%). C-arm CT yielded a true positive in 3 (10%), true negative in 24 (80%), false positive in 1 (3%), and false negative in 2 patients (7%). The specificity and the NPV of hepatic arteriography for the detection of extrahepatic shunting were 88% and 81%, respectively. For C-arm CT the sensitivity, specificity, PPV, NPV, and accuracy for the detection of extrahepatic shunting were 60%, 96%, 75%, 92%, and 90%, respectively. Conclusion: C-arm CT offers additional information to angiography when assessing SIRT patients for extrahepatic shunting. More accurate detection of extrahepatic shunting may optimize the workflow in SIRT preparations by avoiding unnecessary repeat angiographies. (orig.)

  17. Tunable elastic parity-time symmetric structure based on the shunted piezoelectric materials

    Science.gov (United States)

    Hou, Zhilin; Assouar, Badreddine

    2018-02-01

    We theoretically and numerically report on the tunable elastic Parity-Time (PT) symmetric structure based on shunted piezoelectric units. We show that the elastic loss and gain can be archived in piezoelectric materials when they are shunted by external circuits containing positive and negative resistances. We present and discuss, as an example, the strongly dependent relationship between the exceptional points of a three-layered system and the impedance of their external shunted circuit. The achieved results evidence that the PT symmetric structures based on this proposed concept can actively be tuned without any change of their geometric configurations.

  18. Severe Juxtahepatic Venous Injury: Survival after Prolonged Hepatic Vascular Isolation Without Shunting

    Directory of Open Access Journals (Sweden)

    J. E. J. Krige

    1990-01-01

    Full Text Available Survival following major juxtahepatic venous injury is rare in blunt liver trauma despite the use of intracaval shunting. Prolonged liver arterial inflow control, total hepatic venous isolation and lobectomy without shunting was used in a patient to repair a combined vena caval and hepatic venous injury after blunt liver injury. An extended period of normothermic hepatic ischemia was tolerated. Early recognition of retrohepatic venous injury and temporary liver packing to control bleeding and correct hypovolemia are essential before caval occlusion. Hepatic vascular isolation without shunting is an effective simple alternative technique allowing major venous repair in complex liver trauma.

  19. Ventriculoperitoneal shunt for treatment of hydrocephalus in a French bulldog puppy

    Science.gov (United States)

    Giacinti, Jolene A.

    2016-01-01

    A 6.5-week-old bulldog was presented with lethargy, anorexia, and stunted growth. A domed skull, ventrolateral strabismus, hypermetria, and delayed hopping were observed. Congenital hydrocephalus was diagnosed and a ventriculoperitoneal shunt was placed. After surgery, a shunt obstruction occurred but resolved with treatment. The puppy responded well and neurological deficits continued to improve after surgery. PMID:26933271

  20. Congenital extrahepatic portosystemic shunts

    Energy Technology Data Exchange (ETDEWEB)

    Murray, Conor P.; Yoo, Shi-Joon; Babyn, Paul S. [Department of Diagnostic Imaging, Hospital for Sick Children, 555 University Avenue, M5G 1X8, Toronto, Ontario (Canada)

    2003-09-01

    A congenital extrahepatic portosystemic shunt (CEPS) is uncommon. A type 1 CEPS exists where there is absence of intrahepatic portal venous supply and a type 2 CEPS where this supply is preserved. The diagnosis of congenital portosystemic shunt is important because it may cause hepatic encephalopathy. To describe the clinical and imaging features of three children with CEPS and to review the cases in the published literature. The diagnostic imaging and medical records for three children with CEPS were retrieved and evaluated. An extensive literature search was performed. Including our cases, there are 61 reported cases of CEPS, 39 type 1 and 22 type 2. Type 1 occurs predominantly in females, while type 2 shows no significant sexual preponderance. The age at diagnosis ranges from 31 weeks of intrauterine life to 76 years. Both types of CEPS have a number of associations, the most common being nodular lesions of the liver (n=25), cardiac anomalies (n=19), portosystemic encephalopathy (n=10), polysplenia (n=9), biliary atresia (n=7), skeletal anomalies (n=5), and renal tract anomalies (n=4). MRI is recommended as an important means of diagnosing and classifying cases of CEPS and examining the associated cardiovascular and hepatic abnormalities. Screening for CEPS in patients born with polysplenia is suggested. (orig.)

  1. Congenital extrahepatic portosystemic shunts

    International Nuclear Information System (INIS)

    Murray, Conor P.; Yoo, Shi-Joon; Babyn, Paul S.

    2003-01-01

    A congenital extrahepatic portosystemic shunt (CEPS) is uncommon. A type 1 CEPS exists where there is absence of intrahepatic portal venous supply and a type 2 CEPS where this supply is preserved. The diagnosis of congenital portosystemic shunt is important because it may cause hepatic encephalopathy. To describe the clinical and imaging features of three children with CEPS and to review the cases in the published literature. The diagnostic imaging and medical records for three children with CEPS were retrieved and evaluated. An extensive literature search was performed. Including our cases, there are 61 reported cases of CEPS, 39 type 1 and 22 type 2. Type 1 occurs predominantly in females, while type 2 shows no significant sexual preponderance. The age at diagnosis ranges from 31 weeks of intrauterine life to 76 years. Both types of CEPS have a number of associations, the most common being nodular lesions of the liver (n=25), cardiac anomalies (n=19), portosystemic encephalopathy (n=10), polysplenia (n=9), biliary atresia (n=7), skeletal anomalies (n=5), and renal tract anomalies (n=4). MRI is recommended as an important means of diagnosing and classifying cases of CEPS and examining the associated cardiovascular and hepatic abnormalities. Screening for CEPS in patients born with polysplenia is suggested. (orig.)

  2. A Study on the Measurement of Intrapulmonary Shunt in Liver Diseases by the Nucleolide Method

    International Nuclear Information System (INIS)

    Yun, Sung Chul; Ahn, Jae Hee; Choi, Soo Bong

    1987-01-01

    The fact there are increase of intrapulmonary arteriovenous shunt amount in the liver cirrhosis patient has been known since 1950. And the method of shunt amount calculation by radionuclide method using 99m Tc-MAA was introduced in the middle of 1970. We measured intrapulmonary shunt amount by means of perfusion lung scan using 99m Tc-MAA in the various type of liver diseases especially in chronic liver diseases and acute liver disease. The results were as followed. 1) The amount of arteriovenous intrapulmonary shunt in the total case of liver disease was 9.3±3.9%, and that of in the control group was 4.6±2.1%. 2) The amount of arteriovenous intrapulmonary shunt in the chronic liver disease was 10.8±4.4%, and that of in the acute liver disease was 7.2±2.8%. We observed significant differences between normal control group and liver disease group, and between chronic liver disease group and acute liver disease group in the amount of shunt by the nucleolide method.

  3. Continuous monitoring of intracranial pressure after endoscopic third ventriculostomy in the management of CSF shunt failure.

    Science.gov (United States)

    Elgamal, E A

    2010-04-01

    The effectiveness of continuous intracranial pressure (ICP) monitoring in the adaptation period, after endoscopic third ventriculostomy (ETV), and removal of the failed shunt in the management of CSF shunt failure is assessed. Nine patients with active hydrocephalus presenting with CSF shunt obstruction or infection were managed by ETV, removal of the shunt and insertion of an external ventricular drain (EVD) containing an ICP sensor for the purpose of postoperative monitoring of the ICP, and intermittent drainage of CSF. Patient ages ranged from 8 months to 24 years, and six of them were females. Hydrocephalus was obstructive in seven patients, and multiloculated in two. Six patients had an ventriculoperitoneal shunt (VPS), one with a bilateral VPS, one patient had a ventriculoatrial shunt, and one had a VPS and cystoperitoneal shunt (CPS). Shunt failure was caused by obstruction in six patients and infection in three. The post-operative ICP monitoring period ranged from 1-7 days. Intracranial hypertension was persistent in the first day after ETV in 3 patients, and up to 110 mL of CSF were drained to improve its symptoms. ETV was successful in six patients and 3 had permanent VPS. Post-operative continuous ICP monitoring and EVD insertion were very useful in the treatment of CSF shunt failure with ETV. This procedure allowed intermittent CSF drainage, relieving symptoms of elevated ICP, and provided accurate assessment of the success of the ETV and patency of the stoma in the early postoperative days by CT ventriculography and can also be used to install antibiotics in cases of infection.

  4. Medication overuse as a cause of chronic headache in shunted hydrocephalus patients

    DEFF Research Database (Denmark)

    Willer, Lasse; Jensen, R H; Juhler, M

    2010-01-01

    To highlight the group of hydrocephalus patients known to have a long history of shunt revisions and refractory chronic headache. When a shunt in perfect working order has no effect on headache, other causes of headache should be investigated. In this paper, patients with medication overuse...

  5. Piezoelectric Shunt Vibration Damping of F-15 Panel under High Acoustic Excitation

    Science.gov (United States)

    Wu, Shu-Yau; Turner, Travis L.; Rizzi, Stephen A.

    2000-01-01

    At last year's SPIE symposium, we reported results of an experiment on structural vibration damping of an F-15 underbelly panel using piezoelectric shunting with five bonded PZT transducers. The panel vibration was induced with an acoustic speaker at an overall sound pressure level (OASPL) of about 90 dB. Amplitude reductions of 13.45 and 10.72 dB were achieved for the first and second modes, respectively, using single- and multiple-mode shunting. It is the purpose of this investigation to extend the passive piezoelectric shunt-damping technique to control structural vibration induced at higher acoustic excitation levels, and to examine the controllability and survivability of the bonded PZT transducers at these high levels. The shunting experiment was performed with the Thermal Acoustic Fatigue Apparatus (TAFA) at the NASA Langley Research Center using the same F-15 underbelly panel. The TAFA is a progressive wave tube facility. The panel was mounted in one wall of the TAFA test section using a specially designed mounting fixture such that the panel was subjected to grazing-incidence acoustic excitation. Five PZT transducers were used with two shunt circuits designed to control the first and second modes of the structure between 200 and 400 Hz. We first determined the values of the shunt inductance and resistance at an OASPL of 130 dB. These values were maintained while we gradually increased the OASPL from 130 to 154 dB in 6-dB steps. During each increment, the frequency response function between accelerometers on the panel and the acoustic excitation measured by microphones, before and after shunting, were recorded. Good response reduction was observed up to the 148dB level. The experiment was stopped at 154 dB due to wire breakage from vibration at a transducer wire joint. The PZT transducers, however, were still bonded well on the panel and survived at this high dB level. We also observed shifting of the frequency peaks toward lower frequency when the OASPL

  6. Treatment of Hydrocephalus Associated with Neurosarcoidosis by Multiple Shunt Placement

    OpenAIRE

    Kim, Sung Hoon; Lee, Sang Weon; Sung, Soon Ki; Son, Dong Wuk

    2012-01-01

    A 31-year-old man was admitted to our hospital due to hydrocephalus with neurosarcoidosis. Ventriculo-peritoneal shunting was performed in the right lateral ventricle with intravenous methylprednisolone. Subsequently, after 4 months, additional ventriculo-peritoneal shunting in the left lateral ventricle was performed due to the enlarged left lateral ventricle and slit-like right lateral ventricle. After 6 months, he was re-admitted due to upward gaze palsy, and magnetic resonance image showe...

  7. Die transkranielle Doppler-Sonographie zur Identifikation von Rechts-Links-Shunts

    OpenAIRE

    Jekentaite, R. (Ruta)

    2003-01-01

    Paradoxe Embolien über einen Rechts-Links-Shunt (RLS) stellen eine Ursache von Hirninfarkten dar. Diese Shunts werden mittels TEE oder TCD diagnostiziert. Ziele dieser Studie waren die Bestimmung des optimalen Timings des Valsalva-Manövers (VM) sowie Vergleich der zwei Kontrastmittel Echovist®-300 und Echovist®-200. 64 Patienten wurden mittels beider Methoden untersucht. Nach der KM-Injektion wurden die Mikroemboliesignale (MES) in der ACM bilateral dopplersonographisch registriert. Die Unt...

  8. Surgical Outcomes of Ahmed or Baerveldt Tube Shunt Implantation for medically Uncontrolled Traumatic Glaucoma.

    Science.gov (United States)

    Yadgarov, Arkadiy; Liu, Dan; Crane, Elliot S; Khouri, Albert S

    2017-01-01

    To describe postoperative surgical success of either Ahmed or Baerveldt tube shunt implantation for eyes with medically uncontrolled traumatic glaucoma. A review was carried out to identify patients with traumatic glaucoma that required tube shunt implantation between 2009 and 2015 at Rutgers University in Newark, New Jersey, USA. Seventeen eyes from 17 patients met inclusion criteria, including at least 3-month postoperative follow-up. The main outcome measure was surgical success at 1-year follow-up after tube implantation. Mean preoperative intraocular pressure (IOP) was 34.1 ± 8.2 mm Hg on 3.1 ± 1.6 ocular hypotensive medications. Nine eyes (53%) sustained closed globe injury. Ten eyes (59%) received an Ahmed valve shunt and seven eyes (41%) received a Baerveldt tube shunt. Surgical success rate at 1 year postoperatively was 83%. Compared to preoperative, the mean postoperative IOP was significantly lower (16.1 ± 3.5 mm Hg, p Ahmed or Baerveldt tube shunt provided successful control of IOP in patients with medically uncontrollable traumatic glaucoma. Yadgarov A, Liu D, Crane ES, Khouri AS. Surgical Outcomes of Ahmed or Baerveldt Tube Shunt Implantation for medically Uncontrolled Traumatic Glaucoma. J Curr Glaucoma Pract 2017;11(1):16-21.

  9. CT in normal pressure hydrocephalus. Correlation between CT and clinical response to shunting

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, K.; Nogaki, H.; Noda, M.; Kusunoki, T.; Tamaki, N. (Kobe Univ. (Japan). School of Medicine)

    1981-02-01

    CT scans were obtained on 33 patients (age 73y. to 31y.) with the diagnosis of normal pressure hydrocephalus. In each case, the diagnosis was made on the basis of the symptoms, CT and cisternographic findings. Underlying diseases of normal pressure hydrocephalus are ruptured aneurysms (21 cases), arteriovenous malformations (2 cases), head trauma (1 case), cerebrovascular accidents (1 case) and idiopathie (8 cases). Sixteen of 33 patients showed marked improvement, five, moderate or minimal improvement, and twelve, no change. The results were compared with CT findings and clinical response to shunting. CT findings were classified into five types, bases on the degree of periventricular hypodensity (P.V.H.), the extent of brain damage by underlying diseases, and the degree of cortical atrophy. In 17 cases of type (I), CT shows the presence of P.V.H. with or without minimal frontal lobe damage and no cortical atrophy. The good surgical improvements were achieved in all cases of type (I) by shunting. In 4 cases of type (II), CT shows the presence of P.V.H. and severe brain damage without cortical atrophy. The fair clinical improvements were achieved in 2 cases (50%) by shunting. In one case of type (III), CT shows the absence of P.V.H. without brain damage nor cortical atrophy. No clinical improvement was obtained by shunting in this type. In 9 cases of type (IV) with mild cortical atrophy, the fair clinical improvement was achieved in two cases (22%) and no improvement in 7 cases. In 2 cases of type (V) with moderate or marked cortical atrophy, no clinical improvement was obtained by shunting. In conclusion, it appeared from the present study that there was a good correlation between the result of shunting and the type of CT, and clinical response to shunting operation might be predicted by classification of CT findings.

  10. Usefulness of a balloon-expandable, covered stent for the transjugular intrahepatic portosystemic shunt

    Directory of Open Access Journals (Sweden)

    Rössle M

    2018-01-01

    Full Text Available The availability of polytetrafluoroethylene (PTFE covered, self-expandable nitinol stents in 2001 considerably improved the patency, response rates and survival of the transjugular intrahepatic portosystemic shunt (TIPS. Side effects of portosystemic shunting such as hepatic encephalopathy (HE and worsening of hepatic function, however, remained a problem. To reduce HE, underdilatation of nitinol stents has been practiced for many years. However, as shown recently, underdilatation was a flop since, due to their intrinsic memory, nitinol stents always expanded to reach their nominal diameter of 8 or 10 mm. To overcome this problem and to be able to perform permanent shunts with a smaller diameter of < 8 mm, we studied the usefulness of a balloon-expandable, covered, metallic stent which allowed adjustment to any diameter between 5 and 12 mm. Methods: 30 patients with cirrhosis and symptomatic portal hypertension were included. The mean Child-Pugh score was 8 ± 2.17 patients had refractory ascites, 9 patients variceal bleeding and four patients other indications for the TIPS. Results: The TIPS was successfully implanted in all patients within 69.6 ± 21.8 min. The shunt reduced the portosystemic pressure gradient by 57.5 ± 14.2% with a mean stent diameter of 7.4 ± 1.0 mm (5 -10.3 mm. During a mean follow-up of 330 ± 249 days, shunt revision was necessary in 5 patients (17%, four of them had insufficient response and received stent dilatation and one patient had stent misplacement requiring a parallel shunt. Three patients (10% developed HE. Conclusions: The covered, balloon-expandable stent could be placed accurately and allowed creation of adapted shunts with smaller diameters as usual. This resulted in a comparatively low rate of HE.

  11. Effects of isradipine and other calcium antagonists on arteriovenous-shunt flow in anesthetized rabbits and cats

    International Nuclear Information System (INIS)

    Hof, R.P.

    1989-01-01

    The effects of vasodilators on arteriovenous (AV)-shunt flow was investigated in anesthetized cats and rabbits, using the tracer microsphere method. In cats, the calcium antagonist isradipine reduced AV-shunt flow; verapamil showed a similar tendency and nicardipine was without effect. Dihydralazine strongly increased, but nitroglycerin and dipyridamole decreased AV-shunt flow. In rabbits, the effects of isradipine and verapamil were similar to those seen in cats. Sodium nitroprusside had no effect, whereas prazosin, minoxidil, and the potassium-channel activator cromakalim increased AV-shunt flow. The contrasting effects of drugs sharing the same mechanism of action suggest that target-tissue selectivity is more important than the mechanism of action. An increase of AV-shunt flow is unlikely to be beneficial but could be associated with a number of undesirable side effects. It might negatively affect migraine sufferers and, if AV-shunt dilatation shows no tolerance development, it represents an unnecessary hemodynamic burden for the heart

  12. An in vitro lung model to assess true shunt fraction by multiple inert gas elimination.

    Directory of Open Access Journals (Sweden)

    Balamurugan Varadarajan

    Full Text Available The Multiple Inert Gas Elimination Technique, based on Micropore Membrane Inlet Mass Spectrometry, (MMIMS-MIGET has been designed as a rapid and direct method to assess the full range of ventilation-to-perfusion (V/Q ratios. MMIMS-MIGET distributions have not been assessed in an experimental setup with predefined V/Q-distributions. We aimed (I to construct a novel in vitro lung model (IVLM for the simulation of predefined V/Q distributions with five gas exchange compartments and (II to correlate shunt fractions derived from MMIMS-MIGET with preset reference shunt values of the IVLM. Five hollow-fiber membrane oxygenators switched in parallel within a closed extracorporeal oxygenation circuit were ventilated with sweep gas (V and perfused with human red cell suspension or saline (Q. Inert gas solution was infused into the perfusion circuit of the gas exchange assembly. Sweep gas flow (V was kept constant and reference shunt fractions (IVLM-S were established by bypassing one or more oxygenators with perfusate flow (Q. The derived shunt fractions (MM-S were determined using MIGET by MMIMS from the retention data. Shunt derived by MMIMS-MIGET correlated well with preset reference shunt fractions. The in vitro lung model is a convenient system for the setup of predefined true shunt fractions in validation of MMIMS-MIGET.

  13. Cyanide does more to inhibit heme enzymes, than merely serving as an active-site ligand

    Energy Technology Data Exchange (ETDEWEB)

    Parashar, Abhinav [Center for Biomedical Research, VIT University, Vellore, Tamil Nadu, 632014 India (India); Venkatachalam, Avanthika [REDOx Lab, PSG Institute of Advanced Studies, Avinashi Road, Peelamedu, Coimbatore, Tamil Nadu, 641004 (India); Gideon, Daniel Andrew [Center for Biomedical Research, VIT University, Vellore, Tamil Nadu, 632014 India (India); Manoj, Kelath Murali, E-mail: satyamjayatu@yahoo.com [REDOx Lab, PSG Institute of Advanced Studies, Avinashi Road, Peelamedu, Coimbatore, Tamil Nadu, 641004 (India)

    2014-12-12

    Highlights: • Cyanide (CN) is a well-studied toxic principle, known to inhibit heme-enzymes. • Inhibition is supposed to result from CN binding at the active site as a ligand. • Diverse heme enzymes’ CN inhibition profiles challenge prevailing mechanism. • Poor binding efficiency of CN at low enzyme concentrations and ligand pressures. • CN-based diffusible radicals cause ‘non-productive electron transfers’ (inhibition). - Abstract: The toxicity of cyanide is hitherto attributed to its ability to bind to heme proteins’ active site and thereby inhibit their activity. It is shown herein that the long-held interpretation is inadequate to explain several observations in heme-enzyme reaction systems. Generation of cyanide-based diffusible radicals in heme-enzyme reaction milieu could shunt electron transfers (by non-active site processes), and thus be detrimental to the efficiency of oxidative outcomes.

  14. Vaginal Migration of Ventriculoperitoneal Shunt Catheter and Cerebrospinal Fluid Leak as a Complication of Hysterectomy.

    Science.gov (United States)

    Houten, John K; Smith, Shiela; Schwartz, Amit Y

    2017-08-01

    Ventriculoperitoneal (VP) shunting is a common neurosurgical procedure to treat hydrocephalus that diverts cerebrospinal fluid from the cerebral ventricles to the peritoneal cavity for reabsorption. The distal catheter may potentially migrate through any potential or iatrogenic opening in the peritoneal cavity. Increasingly successfully management of childhood hydrocephalus and adult-onset conditions leading to hydrocephalus, such as subarachnoid hemorrhage, is leading many adult female patients harboring VP shunts needing to undergo hysterectomy. Hysterectomy creates a potential defect though which a VP shunt catheter may migrate. It is not known whether the hysterectomy cuff closure technique may affect the likelihood of distal catheter migration though the repair site. We report the case of a 38-year-old woman with a VP shunt who underwent laparoscopic hysterectomy via an open vaginal cuff technique who subsequently presented with vaginal cerebrospinal fluid leakage secondary to migration of the distal shunt catheter through the hysterectomy cuff. Vaginal migration of the distal VP shunt catheter is a possible complication of hysterectomy. The authors postulate that an open cuff hysterectomy closure technique may increase the risk of catheter migration, an issue that may be better understood with further investigation. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Simulation model of harmonics reduction technique using shunt active filter by cascade multilevel inverter method

    Science.gov (United States)

    Andreh, Angga Muhamad; Subiyanto, Sunardiyo, Said

    2017-01-01

    Development of non-linear loading in the application of industry and distribution system and also harmonic compensation becomes important. Harmonic pollution is an urgent problem in increasing power quality. The main contribution of the study is the modeling approach used to design a shunt active filter and the application of the cascade multilevel inverter topology to improve the power quality of electrical energy. In this study, shunt active filter was aimed to eliminate dominant harmonic component by injecting opposite currents with the harmonic component system. The active filter was designed by shunt configuration with cascaded multilevel inverter method controlled by PID controller and SPWM. With this shunt active filter, the harmonic current can be reduced so that the current wave pattern of the source is approximately sinusoidal. Design and simulation were conducted by using Power Simulator (PSIM) software. Shunt active filter performance experiment was conducted on the IEEE four bus test system. The result of shunt active filter installation on the system (IEEE four bus) could reduce THD current from 28.68% to 3.09%. With this result, the active filter can be applied as an effective method to reduce harmonics.

  16. Intrahepatic portal-hepatic venous shunt diagnosed by ultrasonography and computed tomography. Report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Shinagawa, Takashi; Iino, Yasuo; Ukaji, Haruyasu; Ishizuka, Masaharu

    1986-02-01

    Two cases of intrahepatic portal-hepatic venous shunt found by ultrasonography and computed tomography are reported. The first case came to the hospital because of hematuria. A large shunt between the portal vein and the hepatic vein was demonstrated by ultrasonography done for screening, and confirmed by percutaneous transhepatic portography (PTP). The second case was admitted because of cholelithiasis. Computed tomography with contrast enhancement revealed a dilated portal vein in the upper portion of the right lobe. It was subsequently shown by PTP to be a portal-hepatic venous shunt. Portal vein pressure and histological finding of the liver were normal in both cases. The etiology of the shunt was thought to be congenital in these cases for lack of liver disease, portal hypertension and history of trauma. Both cases had no history of hepatic encephalopathy and did not show any symptom attributable to the shunt.

  17. Pre-Liver Transplant: Tips Versus Distal Splenorenal Shunt

    Directory of Open Access Journals (Sweden)

    Thomas W. Faust

    1997-01-01

    Full Text Available Recurrent variceal bleeding in liver transplant candidates with end-stage liver disease can complicate or even prohibit a subsequent transplant procedure (OLT. Endoscopic sclero-therapy and medical therapy are considered as first-line management with surgical shunts reserved for refractory situations. Surgical shunts can be associated with a high mortality in this population and may complicate subsequent OLT. The transjugular intrahepatic portosystemic shunt (TIPS has been recommended in these patients as a bridge to OLT. This is a new modality that has not been compared with previously established therapies such as the distal splenorenal shunt (DSRS. In this study we report our experience with 35 liver transplant recipients who had a previous TIPS (18 patients or DSRS (17 patients for variceal bleeding. The TIPS group had a significantly larger proportion of critically ill and Child-Pugh C patients. Mean operating time was more prolonged in the DSRS group (P=0.014 but transfusion requirements were similar. Intraoperative portal vein blood flow measurements averaged 2132±725 ml/min in the TIPS group compared with 1120±351ml/min in the DSRS group (P<0.001. Arterial flows were similar. Mean ICU and hospital stays were similar. There were 3 hospital mortalities in the DSRS group and none in the TIPS group (P=0.1. We conclude that TIPS is a valuable tool in the management of recurrent variceal bleeding prior to liver transplantation. Intra0Perative hemodynamic measurements suggest a theoretical advantage with TIPS. In a group of patients with advanced liver disease we report an outcome that is similar to patients treated with DSRS prior to liver transplantation. The role of TIPS in the treatment of nontransplant candidates remains to be clarified.

  18. Proteome and membrane fatty acid analyses on Oligotropha carboxidovorans OM5 grown under chemolithoautotrophic and heterotrophic conditions.

    Directory of Open Access Journals (Sweden)

    Debarati Paul

    Full Text Available Oligotropha carboxidovorans OM5 T. (DSM 1227, ATCC 49405 is a chemolithoautotrophic bacterium able to utilize CO and H(2 to derive energy for fixation of CO(2. Thus, it is capable of growth using syngas, which is a mixture of varying amounts of CO and H(2 generated by organic waste gasification. O. carboxidovorans is capable also of heterotrophic growth in standard bacteriologic media. Here we characterize how the O. carboxidovorans proteome adapts to different lifestyles of chemolithoautotrophy and heterotrophy. Fatty acid methyl ester (FAME analysis of O. carboxidovorans grown with acetate or with syngas showed that the bacterium changes membrane fatty acid composition. Quantitative shotgun proteomic analysis of O. carboxidovorans grown in the presence of acetate and syngas showed production of proteins encoded on the megaplasmid for assimilating CO and H(2 as well as proteins encoded on the chromosome that might have contributed to fatty acid and acetate metabolism. We found that adaptation to chemolithoautotrophic growth involved adaptations in cell envelope, oxidative homeostasis, and metabolic pathways such as glyoxylate shunt and amino acid/cofactor biosynthetic enzymes.

  19. Reproducibility of right-to-left shunt quantification using transthoracic contrast echocardiography in hereditary haemorrhagic telangiectasia.

    Science.gov (United States)

    Vorselaars, V M M; Velthuis, S; Huitema, M P; Hosman, A E; Westermann, C J J; Snijder, R J; Mager, J J; Post, M C

    2018-04-01

    Transthoracic contrast echocardiography (TTCE) is recommended for screening of pulmonary arteriovenous malformations (PAVMs) in hereditary haemorrhagic telangiectasia. Shunt quantification is used to find treatable PAVMs. So far, there has been no study investigating the reproducibility of this diagnostic test. Therefore, this study aimed to describe inter-observer and inter-injection variability of TTCE. We conducted a prospective single centre study. We included all consecutive persons screened for presence of PAVMs in association with hereditary haemorrhagic telangiectasia in 2015. The videos of two contrast injections per patient were divided and reviewed by two cardiologists blinded for patient data. Pulmonary right-to-left shunts were graded using a three-grade scale. Inter-observer and inter-injection agreement was calculated with κ statistics for the presence and grade of pulmonary right-to-left shunts. We included 107 persons (accounting for 214 injections) (49.5% male, mean age 45.0 ± 16.6 years). A pulmonary right-to-left shunt was present in 136 (63.6%) and 131 (61.2%) injections for observer 1 and 2, respectively. Inter-injection agreement for the presence of pulmonary right-to-left shunts was 0.96 (95% confidence interval (CI) 0.9-1.0) and 0.98 (95% CI 0.94-1.00) for observer 1 and 2, respectively. Inter-injection agreement for pulmonary right-to-left shunt grade was 0.96 (95% CI 0.93-0.99) and 0.95 (95% CI 0.92-0.98) respectively. There was disagreement in right-to-left shunt grade between the contrast injections in 11 patients (10.3%). Inter-observer variability for presence and grade of the pulmonary right-to-left shunt was 0.95 (95% CI 0.91-0.99) and 0.97 (95% CI 0.95-0.99) respectively. TTCE has an excellent inter-injection and inter-observer agreement for both the presence and grade of pulmonary right-to-left shunts.

  20. A modified Glenn shunt reduces right ventricular stroke work during left ventricular assist device therapy.

    Science.gov (United States)

    Schiller, Petter; Vikholm, Per; Hellgren, Laila

    2016-03-01

    Right ventricular (RV) failure is a major cause of morbidity and mortality after left ventricular assist device (LVAD) placement and remains hard to predict. We hypothesized that partial surgical exclusion of the RV with a modified Glenn shunt during LVAD treatment would reduce RV stroke work. An LVAD was implanted in eight pigs and a modified Glenn shunt was constructed. A conductance pressure-volume catheter was placed in the right ventricle through the apex. Haemodynamic data and pressure-volume loops were obtained at the following time periods: (i) baseline, (ii) open shunt, (iii) LVAD with closed shunt and (iii) LVAD and open shunt. During LVAD therapy, the right atrial (RA) pressure increased from 9 mmHg (9-9) to 15 mmHg (12-15), P = 0.01. RV stroke volume increased from 30 ml (29-40) to 51 ml (42-53), P work increased to 708 mmHg ml (654-1193) from 535 mmHg ml (424-717), P = 0.04, compared with baseline. During LVAD therapy in combination with a Glenn shunt, the RA pressure decreased from 15 mmHg (12-15) to 10 mmHg (7-11) when compared with LVAD therapy only, P = 0.01. A decrease in RV stroke work from 708 mmHg ml (654-1193) to 465 mmHg ml (366-711), P = 0.04, was seen when the LVAD was combined with a shunt, not significantly different from the baseline value (535 mmHg ml). The developed pressure in the right ventricle decreased from 29 mmHg (26-32) to 21 mmHg (20-24), P work during the use of the shunt with LVAD treatment. A modified Glenn shunt reduced RV volumes, RV stroke work and RA pressure during LVAD therapy in an experimental model of heart failure in pigs. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  1. Anatomy and Classification of Gastrorenal and Gastrocaval Shunts

    Science.gov (United States)

    Sabri, Saher S.; Saad, Wael E. A.

    2011-01-01

    The gastric varices communicate with gastrorenal and gastrocaval shunts and are classified according to the pattern of venous inflow into three types, which differ in the number and location of the inflow veins. The gastric varices are also classified according to their venous drainage into four different types, reflecting the size and number of collateral veins communicating with the gastric varices and the gastrorenal/gastrocaval shunt. Lastly, the gastric varices are classified according to their appearance on balloon-occluded retrograde venography into five grades representing the degree of opacification of the gastric varices and the collateral veins. Understanding these anatomic classifications is crucial in planning endovascular obliteration of gastric varices. PMID:22942547

  2. Angiographic and hemodynamic evaluation of the mesoatrial shunt in patients with Budd-Chiari syndrome and inferior vena caval obstruction

    International Nuclear Information System (INIS)

    Redmond, P.L.; Kadir, S.; Cameron, J.L.; Kaufman, S.L.; White, R.I. Jr.

    1986-01-01

    Obstruction of the inferior vena cava (IVC) is not uncommon in patients with the Budd-Chiari syndrome. The caval obstruction may be due to thrombus or compression by an enlarged caudate lobe. Conventional portosystemic shunts are not possible in the presence of an obstructed IVC; the mesoatrial shunt is indicated in these patients. Between 1973 and 1986, the authors studied 13 patients (ten female, three male) with Budd-Chiari syndrome and IVC obstruction in whom mesoatrial shunts were subsequently constructed. Polycythemia rubra vera was the most common predisposing condition. Preoperative evaluation included US, scintigraphy, CT, and angiography (hepatic arteriography, hepatic venography and pressure measurements, inferior vena cavography, arterial portography). Postoperatively shunts were assessed angiographically and hemodynamically, and several patients underwent CT. The shunts were catheterized via a brachial or femoral venous approach, which allowed pressures along the shunt from the superior mesenteric vein to the right atrium to be measured. The mesoatrial shunt is a relatively new procedure which is indicated in patients with the Budd-Chiari syndrome complicated by IVC obstruction. Shunt patency may be demonstrated arteriographically or with CT, but hemodynamic evaluation with measurement of pressure gradients is required to assess shunt function

  3. Radionuclide angiocardiography. Improved diagnosis and quantitation of left-to-right shunts using area ratio techniques in children

    International Nuclear Information System (INIS)

    Alderson, P.O.; Jost, R.G.; Strauss, A.W.; Boonvisut, S.; Markham, J.

    1975-01-01

    A comparison of several reported methods for detection and quantitation of left-to-right shunts by radionuclides was performed in 50 children. Count ratio (C2/C1) techniques were compared with the exponential extrapolation and gamma function area ratio techniques. C2/C1 ratios accurately detected shunts and could reliably separate shunts from normals, but there was a high rate of false positives in children with valvular heart disease. The area ratio methods provided more accurate shunt quantitation and a better separation of patients with valvular heart disease than did the C2/C1 ratio. The gamma function method showed a higher correlation with oximetry than the exponential method, but the difference was not statistically significant. For accurate shunt quantitation and a reliable separation of patients with valvular heart disease from those with shunts, area ratio calculations are preferable to the C2/C1 ratio

  4. Delayed Catheter-Related Intracranial Hemorrhage After a Ventriculoperitoneal or Ventriculoatrial Shunt in Hydrocephalus.

    Science.gov (United States)

    Qian, Zhouqi; Gao, Liang; Wang, Ke; Pandey, Sajan

    2017-11-01

    Delayed catheter-related intracranial hemorrhage is not rare after a ventriculoperitoneal (VP) or ventriculoatrial (VA) shunt for the treatment of hydrocephalus. Immediate postoperative catheter-related intracranial hemorrhage is possibly due to the procedure itself; however, delayed intracranial hemorrhage may have other underlying mechanisms. This study aimed to investigate the clinical characteristics and reveal the risk factors of delayed catheter-related intracranial hemorrhage after a VP or VA shunt. We did a retrospective study to review patients with hydrocephalus and underwent VP or VA shunt in our department from September 2011 to December 2015. We reviewed the clinical characteristics of the patients with delayed catheter-related intracranial hemorrhage, and its risk factors were analyzed with SPSS 16.0. Of the 218 patients enrolled in the study (145 male, 73 female), 17 (7.8%) patients experienced delayed catheter-related intracranial hemorrhage, including 11 of 151 (7.3%) patients with a VP shunt and 6 of 67 (9.0%) patients with a VA shunt. Additionally, 4 of the 16 patients with postoperative low-molecular-weight heparin (LMWH) therapy and 13 of the 202 patients without LMWH experienced bleeding, showing a significant difference (25% vs. 6.4%, P = 0.026). The relative risk was 4.8 (95% confidence interval: 1.4-17.1). Delayed catheter-related intracranial hemorrhage is not rare after a VP or VA shunt. However, most patients can be cured after appropriate treatment. Postoperative anticoagulation therapy with enoxaparin may be associated with an increased risk of bleeding. Copyright © 2017. Published by Elsevier Inc.

  5. Improving the Thermostability and Optimal Temperature of a Lipase from the Hyperthermophilic Archaeon Pyrococcus furiosus by Covalent Immobilization

    Directory of Open Access Journals (Sweden)

    Roberta V. Branco

    2015-01-01

    Full Text Available A recombinant thermostable lipase (Pf2001Δ60 from the hyperthermophilic Archaeon Pyrococcus furiosus (PFUL was immobilized by hydrophobic interaction on octyl-agarose (octyl PFUL and by covalent bond on aldehyde activated-agarose in the presence of DTT at pH = 7.0 (one-point covalent attachment (glyoxyl-DTT PFUL and on glyoxyl-agarose at pH 10.2 (multipoint covalent attachment (glyoxyl PFUL. The enzyme’s properties, such as optimal temperature and pH, thermostability, and selectivity, were improved by covalent immobilization. The highest enzyme stability at 70°C for 48 h incubation was achieved for glyoxyl PFUL (around 82% of residual activity, whereas glyoxyl-DTT PFUL maintained around 69% activity, followed by octyl PFUL (27% remaining activity. Immobilization on glyoxyl-agarose improved the optimal temperature to 90°C, while the optimal temperature of octyl PFUL was 70°C. Also, very significant changes in activity with different substrates were found. In general, the covalent bond derivatives were more active than octyl PFUL. The E value also depended substantially on the derivative and the conditions used. It was observed that the reaction of glyoxyl-DTT PFUL using methyl mandelate as a substrate at pH 7 presented the best results for enantioselectivity E=22 and enantiomeric excess (ee (% = 91.

  6. Comparison of series regulated neutral beam accel supplies with shunt regulated accel supplies

    International Nuclear Information System (INIS)

    Baker, W.; Smith, B.H.

    1976-01-01

    This study was undertaken to get a direct comparison between comparable series and shunt regulated power supplies. It is intended that the two supplies will be strictly equivalent with the same safety factors in the design of each type and the cost estimates made on the same basis. The series regulated power supply is simply a scaled up version of the 2XIIB Accel Supplies. Each supply provides 150 kV, 65 ampere, 500 ms pulse output such as will be used on the TFTR sources. The shunt regulated power supply uses high reactance transformers to provide the series impedance for the shunt regulator. The most significant difference in the performance of the two types of power supplies is that the shunt regulated supply has a minimum interrupt period of 16 ms, whereas the series regulated supply can have about 0.5 ms. Even this difference can be eliminated with a commutator circuit such as is being developed in Berkeley for the 150 kV, 20 ampere system. The 16 ms period is probably not a very serious limitation because it still permits up to 31 interrupts per 500 ms pulse. The shunt regulated system appears to be about 37 percent less expensive than the series system

  7. A case of repeated intracerebral hemorrhages secondary to ventriculoperitoneal shunt

    Directory of Open Access Journals (Sweden)

    Jinbing Zhao

    2015-03-01

    Full Text Available Ventriculoperitoneal shunt is a routinely performed treatment in neurosurgical department. Intracerebral hemorrhage, as a complication after shunt catheterization, is really rare but with high mortality. In this study, we reported a case of a 74-year-old man who suffered from repeated intracerebral hemorrhage after ventriculoperitoneal shunt. The first hemorrhage happened 63 h after the 1st surgery, and most hematomas were located in the ipsilateral occipital lobe and intraventricles, along the ventricular catheter. Fresh blood clot casts blocked the external ventricular draining catheter, which was inserted into the right front horn during the 3rd surgery, indicating new intraventricular bleeding happened. A large hematoma in ipsilateral frontal lobe was detected on the 3rd day after the removal of external ventricular draining catheter. Different hemorrhagic locations and time points were encountered on the same case. We discussed the possible causes of repeated hemorrhage for this case, and the pre-operative preparation including risk evaluation in future clinical work.

  8. Active inductor shunt peaking in high-speed VCSEL driver design

    CERN Document Server

    Liang, Futian; Hou, Suen; Liu, Chonghan; Liu, Tiankuan; Su, Da-Shung; Teng, Ping-Kun; Xiang, Annie; Ye, Jingbo; Jin, Ge

    2013-01-01

    An all transistor active inductor shunt peaking structure has been used in a prototype of 8-Gbps high-speed VCSEL driver which is designed for the optical link in ATLAS liquid Argon calorimeter upgrade. The VCSEL driver is fabricated in a commercial 0.25-um Silicon-on-Sapphire (SoS) CMOS process for radiation tolerant purpose. The all transistor active inductor shunt peaking is used to overcome the bandwidth limitation from the CMOS process. The peaking structure has the same peaking effect as the passive one, but takes a small area, does not need linear resistors and can overcome the process variation by adjust the peaking strength via an external control. The design has been tapped out, and the prototype has been proofed by the preliminary electrical test results and bit error ratio test results. The driver achieves 8-Gbps data rate as simulated with the peaking. We present the all transistor active inductor shunt peaking structure, simulation and test results in this paper.

  9. Noninvasive measurement of nutrient portal blood shunting: an experimental study with [14C]ursodeoxycholic acid

    International Nuclear Information System (INIS)

    Nordlinger, B.; Parquet, M.; Infante, R.; Moreels, R.; Blondiau, P.; Boschat, M.; Groussard, M.; Huguet, C.

    1982-01-01

    All of the methods proposed for measuring portal blood flow are either invasive, estimate total rather than nutrient flow, and none has proved reliable in cirrhotic patients. A method has been derived from pharmacokinetic principles used for the calculation of bioavailability of drugs according to the route of administration (i.v. or p.o.) and tested experimentally in 20 pigs. A tracer dose of [ 14 C]ursodeoxycholic acid, a biliary acid with a high-liver first-pass effect, is administered in the duodenum, and serial peripheral blood samples are taken. Later, the same dose of the same drug is administered i.v. The shunt fraction of portal blood F is obtained by the ratio of the areas under the plasma level vs. time curves (AUC) after p.o. and i.v. administrations: (see formula in text). The pigs were divided into three experimental groups. (i) Group I: undisturbed portal flow; (ii) Group II: total diversion of portal blood with an end-to-side portacaval shunt, and (iii) Group III: partial diversion of portal blood through a side-to-side portacaval shunt. Portal flow was measured during surgery with an electromagnetic flowmeter above and below the shunt and the degree of shunting calculated. Results show that the shunt fraction measured with ursodeoxycholic acid is well-correlated with hemodynamic data. No overlap between Groups I and III is observed. It is concluded that the shunt fraction of nutrient portal blood can be measured with this noninvasive method. Minute amounts of ursodeoxycholic acid were used in order to be completely metabolized by the liver, even in spite of hepatocellular dysfunction. Therefore, this method should be valid in cirrhotic patients and be useful to decide the type of portasystemic shunt to propose for the decompression of gastroesophageal varices

  10. Resonant Electromagnetic Shunt Damping of Flexible Structures

    DEFF Research Database (Denmark)

    Høgsberg, Jan Becker

    2016-01-01

    Electromagnetic transducers convert mechanical energy to electrical energy and vice versa. Effective passive vibration damping of flexible structures can therefore be introduced by shunting with an accurately calibrated resonant electrical network thatcontains a capacitor to create the desired...

  11. The CHESS score: a simple tool for early prediction of shunt dependency after aneurysmal subarachnoid hemorrhage.

    Science.gov (United States)

    Jabbarli, R; Bohrer, A-M; Pierscianek, D; Müller, D; Wrede, K H; Dammann, P; El Hindy, N; Özkan, N; Sure, U; Müller, O

    2016-05-01

    Acute hydrocephalus is an early and common complication of aneurysmal subarachnoid hemorrhage (SAH). However, considerably fewer patients develop chronic hydrocephalus requiring shunt placement. Our aim was to develop a risk score for early identification of patients with shunt dependency after SAH. Two hundred and forty-two SAH individuals who were treated in our institution between January 2008 and December 2013 and survived the initial impact were retrospectively analyzed. Clinical parameters within 72 h after the ictus were correlated with shunt dependency. Independent predictors were summarized into a new risk score which was validated in a subsequent SAH cohort treated between January and December 2014. Seventy-five patients (31%) underwent shunt placement. Of 23 evaluated variables, only the following five showed independent associations with shunt dependency and were subsequently used to establish the Chronic Hydrocephalus Ensuing from SAH Score (CHESS, 0-8 points): Hunt and Hess grade ≥IV (1 point), location of the ruptured aneurysm in the posterior circulation (1 point), acute hydrocephalus (4 points), the presence of intraventricular hemorrhage (1 point) and early cerebral infarction on follow-up computed tomography scan (1 point). The CHESS showed strong correlation with shunt dependency (P = 0.0007) and could be successfully validated in both internal SAH cohorts tested. Patients scoring ≥6 CHESS points had significantly higher risk of shunt dependency (P CHESS may become a valuable diagnostic tool for early estimation of shunt dependency after SAH. Further evaluation and external validation will be required in prospective studies. © 2016 EAN.

  12. Medication overuse as a cause of chronic headache in shunted hydrocephalus patients

    DEFF Research Database (Denmark)

    Willer, Lasse; Jensen, R H; Juhler, M

    2010-01-01

    To highlight the group of hydrocephalus patients known to have a long history of shunt revisions and refractory chronic headache. When a shunt in perfect working order has no effect on headache, other causes of headache should be investigated. In this paper, patients with medication overuse...... headache are identified and the positive effect of medication withdrawal are described....

  13. Design and test of a novel isolator with negative resistance electromagnetic shunt damping

    International Nuclear Information System (INIS)

    Yan, Bo; Zhang, Xinong; Niu, Hongpan

    2012-01-01

    This paper proposes a negative resistance electromagnetic shunt damping vibration isolator and investigates the effectiveness of the isolator. The isolator consists of a shunt circuit and a pair of electromagnet and permanent magnets that are pasted onto a box-shaped spring. A kind of negative resistance shunt impedance is proposed to cancel the inherent resistance of the electromagnet. The electromechanical coupling coefficient and the electromagnetic damping force calculation formula are obtained by Biot–Savart’s law and Ampère’s law, respectively. A single degree of freedom system is employed to verify the performance of the proposed isolator. The governing equation is established. The performance of the proposed isolator under a half-cycle sine pulse is investigated and discussed. Experiments were carried out and the results agreed well with the numerical predictions. Both the results demonstrate that the negative resistance electromagnetic shunt damping vibration isolator could suppress vibration transmitted to the structure effectively. (paper)

  14. Permanent right-to-left shunt is the key factor in managing patent foramen ovale.

    Science.gov (United States)

    Rigatelli, Gianluca; Dell'Avvocata, Fabio; Cardaioli, Paolo; Giordan, Massimo; Braggion, Gabriele; Aggio, Silvio; Chinaglia, Mauro; Mandapaka, Sangeeta; Kuruvilla, John; Chen, Jack P; Nanjundappa, Aravinda

    2011-11-15

    We sought to prospectively evaluate risk of stroke and impact of transcatheter patent foramen ovale (PFO) closure in patients with permanent right-to left shunt compared with those with Valsalva maneuver-induced right-to-left shunt. Pathophysiology and properly management of PFO still remain far from being fully clarified: in particular, the contribution of permanent right-to-left shunt remains unknown. Between March 2006 and October 2010, we enrolled 180 (mean age 44 ± 10.9 years, 98 women) of 320 consecutive patients referred to our center for transcatheter PFO closure, who had spontaneous permanent right-to-left shunt on transcranial Doppler and transthoracic/transesophageal echocardiography. All patients fulfilled the standard current indications for transcatheter closure and underwent preoperative transesophageal echocardiography and brain magnetic resonance imaging, with subsequent intracardiac echocardiographic-guided transcatheter PFO closure. We compared the clinical echocardiographic characteristics of these patients (Permanent Group) with the rest of 140 patients with right-to-left shunt only during Valsalva maneuver (Valsalva Group). Compared with the Valsalva Group patients, patients of the Permanent Group had increased frequency of multiple ischemic brain lesions on magnetic resonance imaging, previous recurrent stroke, previous peripheral arteries embolism, migraine with aura, and-more frequently-atrial septal aneurysm and prominent Eustachian valve. The presence of permanent shunt confers the highest risk of recurrent stroke (odds ratio: 5.9, 95% confidence interval: 2.0 to 12, p < 0.001). No differences were recorded between the 2 groups with regard to recurrence of ischemic events after the closure procedure. Despite its small-sample nature, our study suggests that patients with permanent right-to-left shunt have potentially a higher risk of paradoxical embolism compared with those without. Copyright © 2011 American College of Cardiology

  15. Controversies: Optic nerve sheath fenestration versus shunt placement for the treatment of idiopathic intracranial hypertension

    Directory of Open Access Journals (Sweden)

    Arielle Spitze

    2014-01-01

    Full Text Available Background: Idiopathic intracranial hypertension (IIH has been increasing in prevalence in the past decade, following the obesity epidemic. When medical treatment fails, surgical treatment options must be considered. However, controversy remains as to which surgical procedure is the preferred surgical option - optic nerve sheath fenestration (ONSF or cerebrospinal fluid (CSF shunting - for the long-term treatment of this syndrome. Purpose: To provide a clinical update of the pros and cons of ONSF versus shunt placement for the treatment of IIH. Design: This was a retrospective review of the current literature in the English language indexed in PubMed. Methods: The authors conducted a PubMed search using the following terms: Idiopathic IIH, pseudotumor cerebri, ONSF, CSF shunts, vetriculo-peritoneal shunting, and lumbo-peritoneal shunting. The authors included pertinent and significant original articles, review articles, and case reports, which revealed the new aspects and updates in these topics. Results: The treatment of IIH remains controversial and lacks randomized controlled clinical trial data. Treatment of IIH rests with the determination of the severity of IIH-related visual loss and headache. Conclusion: The decision for ONSF versus shunting is somewhat institution and surgeon dependent. ONSF is preferred for patients with visual symptoms whereas shunting is reserved for patients with headache. There are positive and negative aspects of both procedures, and a prospective, randomized, controlled trial is needed (currently underway. This article will hopefully be helpful in allowing the reader to make a more informed decision until that time.

  16. Spontaneous expectoration of a Blalock-Taussig shunt a decade after operation

    Directory of Open Access Journals (Sweden)

    Shyam S Kothari

    2015-01-01

    Full Text Available An eleven-year-old boy expectorated a foreign body in cough that was identified as the prosthetic graft used for a Blalock-Taussig shunt. The shunt procedure was done 10 years earlier, and a definitive repair for tetralogy of Fallot was done a year later. He had no other symptoms, and a computed tomography (CT angiogram did not reveal any other significant anomaly. The reason for this extremely rare event is unclear.

  17. Encefalopatía hepática secundaria a la existencia de un shunt portosistémico tratada satisfactoriamente mediante radiología intervencionista Hepatic encephalophaty secondary to porto-systemic shunt satisfactorily treated with interventionist radiology

    Directory of Open Access Journals (Sweden)

    L. Crespo

    2007-11-01

    Full Text Available La encefalopatía hepática es un estado reversible de alteración en la función cognitiva, que puede ocurrir en pacientes con enfermedad hepática aguda o crónica o shunts porto-sistémicos, en el que puede aparecer cualquiera de los signos neurológicos o psiquiátricos conocidos. Las sustancias nitrogenadas procedentes de la digestión intestinal alcanzan el cerebro sin la depuración que supone su paso por el hígado, debido a las derivaciones porto-sistémicas, y dan lugar a los signos característicos de la encefalopatía hepática. A continuación presentamos dos casos clínicos de pacientes con shunt porto-sistémicos, diagnosticados de encefalopatía hepática crónica recurrente refractaria al tratamiento médico convencional, tratados satisfactoriamente con embolización de dicho shunt mediante técnicas de radiología intervencionista.Hepatic encephalopathy is a reversible state of altered cognition that may occur in patients with acute or chronic liver disease or porto-systemic shunt, and in which known neurological or psychiatric signs may develop. Nitrogenated substances from intestinal digestion reach the brain without being cleared by their passage through the liver due to the presence of porto-systemic shunt. We report two cases of patients with porto-systemic shunt diagnosed with recurrent chronic hepatic encephalopathy refractory to conventional medical treatment. They were satisfactorily treated with shunt embolization using interventionist radiology techniques.

  18. Simulation and Hardware Implementation of Shunt Active Power Filter Based on Synchronous Reference Frame Theory

    Directory of Open Access Journals (Sweden)

    Karthikrjan Senthilnathan

    2018-02-01

    Full Text Available This paper describes about the Hybrid Shunt Active Power Filter (HSAPF for the elimination of the current harmonics in the line side of the three phase three wire systems. The Active Power Filter is based on the Voltage Source Converter (VSC topology. The control strategy for the converter is based on Synchronous Reference Frame (SRF theory. The compensation of harmonics is done by the APF which is connected in the shunt configuration to the system. The Shunt APF has the better compensation of current harmonics. The design and implementation of Shunt active power filter is done by MATLAB/Simulink. The real time implementation by using the ATMEGA 8 Microcontroller. The Simulation and Hardware results shows that the current harmonics are eliminated in the system

  19. The transjugular portosystemic stent shunt (TIPSS) as an intervention in clinical complication of portal hypertension

    International Nuclear Information System (INIS)

    Thalhammer, A.; Jacobi, V.; Schwarz, W.; Balzer, J.; Abolmaali, N.; Vogl, T.J.

    2001-01-01

    Most frequent complications in patients with liver cirrhosis are due to portal hypertension. Beside ascites circumvent vessles formate with vasodilatation. Due to counterregulation a secondary hyperaldosteronism develops with release of vasocontrictive agents. If conservative and endoscopic methods fail, indication for building a portosystemic shunt is given. The TIPSS procedure is less invasive than the surgical method of Warren-Shunt, so the radiological intervention has replaced surgery. Reducing the portal pressure by the shunt, the clinical complications change for the better. Still problems are defined as hepatic encephalopathy and right ventricular heart failure. Regular follow up investigations have to be performed to detect complications in the shunt. Using regular clinical and radiological check up TIPSS is of clinical benefit with good long term results. (orig.) [de

  20. Subdural haematoma complicating shunting for normal pressure hydrocephalus in the setting of concomitant antiplatelet medication

    DEFF Research Database (Denmark)

    Birkeland, Peter; Lauritsen, Jens; Poulsen, Frantz Rom

    2016-01-01

    OBJECTIVE: To report on the occurrence and management of subdural haematoma after shunt implantation for normal pressure hydrocephalus and to determine the risk of recurrence in the setting of antiplatelet medication. METHODS: From a consecutive series of 80 patients implanted with a cerebrospinal...... fluid shunt for normal pressure hydrocephalus, records from 11 patients taking antiplatelet drugs, who subsequently had surgery for subdural haematoma were extracted and retrospectively reviewed. RESULTS: Patients were followed up for a mean of 1819 days after shunt implantation. Subdural haematomas...... reoperations done before the subdural collection disappeared. Only one patient had a late recurrence almost 11 years after shunt implantation. CONCLUSIONS: Subdural haematoma in the setting of a ventriculoperitoneal implantation for normal pressure hydrocephalus and concomitant antiplatelet medication can...

  1. MR imaging of pulsatile CSF movement in hydrocephalus communicans before and after CSF shunt implantation

    International Nuclear Information System (INIS)

    Goldmann, A.; Kunz, U.; Rotermund, F.; Friedrich, J.M.; Schnarkowski, P.

    1992-01-01

    16 patients with hydrocephalus communicans and 5 healthy volunteers were examined to demonstrate the pattern of the pulsatile CSF flow. After implantation of a CSF shunt system the same patients were examined again to show the influence of the shunt on the CSF pulsations. We used a flow-sensitised, cardiac-gated 2D FLASH sequence and analysed the phase and magnitude images. It could be shown that most patients (n=12) had a hyerdynamic pulsatile flow preoperatively. After shunt implantation the pulsatile CSF motion and the clinical symptoms were improved in 8 of these patients. MRI of pulsatile CSF flow movement seems to be a helpful noninvasive tool to estimate the prognosis of a shunt implantation in patients with hydrocephalus communicans. (orig.) [de

  2. Post-TIPS Hepatic Encephalopathy Treated by Occlusion Balloon-Assisted Retrograde Embolization of a Coexisting Spontaneous Splenorenal Shunt

    International Nuclear Information System (INIS)

    Shioyama, Yasukazu; Matsueda, Kiyoshi; Horihata, Koushi; Kimura, Masashi; Nishida, Norifumi; Kishi, Kazushi; Terada, Masaki; Sato, Morio; Yamada, Ryusaku

    1996-01-01

    A 51-year-old man with posthepatitis cirrhosis underwent a transjugular intrahepatic portosystemic shunt (TIPS) for bleeding of recurrent esophageal varices. The patient had a coexisting, spontaneous, splenorenal shunt. He subsequently developed hepatic encephalopathy, presumably due to excessive portosystemic shunting. Since medical management resulted in no significant improvement, the splenorenal shunt was embolized from the jugular vein approach via renal vein access during temporary balloon occlusion. Within a few days, the patient's hepatic encephalopathy resolved. Twelve months later the patient showed no recurrence of encephalopathy and had maintained a patent TIPS

  3. Controversy about Management of Hydrocephalus - Shunt vs. Endoscopic Third Ventriculostomy.

    Science.gov (United States)

    Kumar, Vikas; Bodeliwala, Shaam; Singh, Daljit

    2017-08-01

    The best management of hydrocephalus is still controversial in the twenty-first century. Shunt treatment for hydrocephalus is the most common procedure performed in neurosurgical practice and is associated with the highest complications rate. But during the last 2 decades, the treatment of hydrocephalus has improved with better shunt devices available today, increased facilities for investigations and newer approaches like endoscopic third ventriculostomy. The recent advances in development of better endoscopes have provided the patient and treating doctor with an option for an alternative surgery for treatment of hydrocephalus.

  4. Chatter reduction in boring process by using piezoelectric shunt damping with experimental verification

    Science.gov (United States)

    Yigit, Ufuk; Cigeroglu, Ender; Budak, Erhan

    2017-09-01

    Chatter is a self-excited type of vibration that develops during machining due to process-structure dynamic interactions resulting in modulated chip thickness. Chatter is an important problem as it results in poor surface quality, reduced productivity and tool life. The stability of a cutting process is strongly influenced by the frequency response function (FRF) at the cutting point. In this study, the effect of piezoelectric shunt damping on chatter vibrations in a boring process is studied. In piezoelectric shunt damping method, an electrical impedance is connected to a piezoelectric transducer which is bonded on cutting tool. Electrical impedance of the circuit consisting of piezoceramic transducer and passive shunt is tuned to the desired natural frequency of the cutting tool in order to maximize damping. The optimum damping is achieved in analytical and finite element models (FEM) by using a genetic algorithm focusing on the real part of the tool point FRF rather than the amplitude. Later, a practical boring bar is considered where the optimum circuit parameters are obtained by the FEM. Afterwards, the effect of the optimized piezoelectric shunt damping on the dynamic rigidity and absolute stability limit of the cutting process are investigated experimentally by modal analysis and cutting tests. It is both theoretically and experimentally shown that application of piezoelectric shunt damping results in a significant increase in the absolute stability limit in boring operations.

  5. Tube shunt complications and their prevention.

    Science.gov (United States)

    Sarkisian, Steven R

    2009-03-01

    Glaucoma drainage devices (GDDs) have been generally accepted as a treatment of refractory glaucoma. GDDs have their own unique set of complications that are important to evaluate to prevent them. Tube shunts are typically used in eyes with refractory glaucoma. There is increased interest in studying the efficacy of GDDs. Most of the attention has been focused on comparing trabeculectomy with the Baerveldt implant (Advanced Medical Optics, Inc., Santa Anna, California, USA). The other leading implant is the Ahmed Glaucoma Valve. There are several retrospective studies comparing these two devices and a prospective study is ongoing. There is great interest in the complication rate of tube shunts and these have been published both retrospectively and prospectively. Complications such as hypotony, diplopia, strabismus, proptosis, tube erosion, failure, corneal decompensation, endophthalmitis, and visual loss are all important and some have recently been reviewed in the literature. Moreover, the use of glaucoma drainage implants in the pediatric population has been evaluated. Glaucoma drainage implants have been a powerful tool in our surgical fight to prevent blindness; however, they are not without complications or controversy.

  6. Risk factors for stent graft thrombosis after transjugular intrahepatic portosystemic shunt creation.

    Science.gov (United States)

    Jahangiri, Younes; Kerrigan, Timothy; Li, Lei; Prosser, Dominik; Brar, Anantnoor; Righetti, Johnathan; Schenning, Ryan C; Kaufman, John A; Farsad, Khashayar

    2017-12-01

    To identify risk factors of stent graft thrombosis after transjugular intrahepatic portosystemic shunt (TIPS) creation. Patients who underwent TIPS creation between June 2003 and January 2016 and with follow-up assessing stent graft patency were included (n=174). Baseline comorbidities, liver function, procedural details and follow-up liver function tests were analyzed in association with hazards of thrombosis on follow-up. Competing risk cox regression models were used considering liver transplant after TIPS creation as the competing risk variable. One-, 2- and 5-year primary patency rates were 94.1%, 91.7% and 78.2%, respectively. Patient age [sub-hazard ratio (sHR): 1.13; P=0.001], body mass index (BMI) value for trend=0.017). Older age, lower BMI and higher post-TIPS portosystemic gradients were associated with higher hazards of shunt thrombosis after TIPS creation using stent grafts. Higher rates of shunt thrombosis were seen in patients for whom TIPS creation was clinically unsuccessful. The association between TIPS thrombosis and higher post-TIPS portosystemic gradients may indicate impaired flow through the shunt, a finding which may be technical or anatomic in nature and should be assessed before procedure completion.

  7. Right Lower Quadrant Abdominal Pain in a Patient with Prior Ventriculoperitoneal Shunting: Consider the Tip!

    Directory of Open Access Journals (Sweden)

    Petros Charalampoudis

    2012-01-01

    Full Text Available Introduction. Ventriculoperitoneal (VP shunting is the treatment of choice for nonobstructive hydrocephalus. In patients with such a device, right lower quadrant abdominal pain can puzzle the surgeon, posing a differential diagnostic problem among appendicitis, nonsurgical colicky pain, and primary shunt catheter tip infection. Treatment is different in either case. Presentation of Case. We hereby present a case of a young woman with prior ventriculoperitoneal shunt positioning who presented to our department with right lower quadrant abdominal pain. The patient underwent a 24-hour observation including a neurosurgery consult in order to exclude acute appendicitis and VP shunt tip infection. Twenty four hours later, the patient’s symptomatology improved, and she was discharged with the diagnosis of atypical colicky abdominal pain seeking a gastroenterologist consult. Discussion. This case supports that when a patient with prior VP shunting presents with right lower quadrant abdominal pain, differential diagnosis can be tricky for the surgeon. Conclusion. Apart from acute appendicitis, primary or secondary VP catheter tip infection must be considered because the latter can be disastrous.

  8. Haematology and coagulation profiles in cats with congenital portosystemic shunts.

    Science.gov (United States)

    Tzounos, Caitlin E; Tivers, Michael S; Adamantos, Sophie E; English, Kate; Rees, Alan L; Lipscomb, Vicky J

    2017-12-01

    Objectives The objectives of this study were, first, to report the haematological parameters and coagulation times for cats with a congenital portosystemic shunt (CPSS) and the influence of surgical shunt attenuation on these parameters; and, second, to identify any association between prolongation in coagulation profiles and incidence of perioperative haemorrhage. Methods This was a retrospective clinical study using client-owned cats with a CPSS. Signalment, shunt type (extra- or intrahepatic), degree of shunt attenuation (complete or partial), haematological parameters, prothrombin time (PT) and activated partial thromboplastin time (aPTT) test results, and occurrence of any perioperative clinical bleeding complications were recorded for cats undergoing surgical treatment of a CPSS at the Royal Veterinary College, UK, between 1994 and 2011. Results Forty-two cats were included. Thirty-six (85.7%) had an extrahepatic CPSS and six (14.3%) had an intrahepatic CPSS. Preoperatively, mean cell volume (MCV) and mean cell haemoglobin (MCH) were below the reference interval (RI) in 32 (76.2%) and 31 (73.8%) cats, respectively. Red blood cell count and mean cell haemoglobin concentration (MCHC) were above the RI in 10 (23.8%) and eight (19.1%) cats, respectively. Postoperatively, there were significant increases in haematocrit ( P = 0.044), MCV ( P = 0.008) and MCH ( P = 0.002). Despite the significant increase in MCV postoperatively, the median MCV postoperatively was below the RI, indicating persistence of microcytosis. Preoperatively, PT was above the upper RI in 14 cats (87.5%), and aPTT was above the upper RI in 11 cats (68.8%). No cat demonstrated a perioperative clinical bleeding complication. Conclusions and relevance Cats with a CPSS are likely to present with a microcytosis, but rarely present with anaemia, leukocytosis or thrombocytopenia. Surgical attenuation of the CPSS results in a significant increase in the HCT and MCV. Coagulation profiles in cats with a

  9. Exercise-induced arteriovenous intrapulmonary shunting in dogs.

    Science.gov (United States)

    Stickland, Michael K; Lovering, Andrew T; Eldridge, Marlowe W

    2007-08-01

    We have previously shown, using contrast echocardiography, that intrapulmonary arteriovenous pathways are inducible in healthy humans during exercise; however, this technique does not allow for determination of arteriovenous vessel size or shunt magnitude. The purpose of this study was to determine whether large-diameter (more than 25 microm) intrapulmonary arteriovenous pathways are present in the dog, and whether exercise recruits these conduits. Through the right forelimb, 10.8 million 25-microm stable isotope-labeled microspheres (BioPAL, Inc., Worcester, MA) were injected either at rest (n = 8) or during high-intensity exercise (6- 8 mph, 10-15% grade, n = 6). Systemic arterial blood was continuously sampled during and for 3 minutes after injection. After euthanasia, tissue samples were obtained from the heart, liver, kidney, and skeletal muscle. In addition, 25- and 50-microm microspheres were infused into four isolated dog lungs that were ventilated and perfused at constant pressures similar to exercise. Blood and tissue samples were commercially analyzed for the presence of microspheres. No microspheres were detected in the arterial blood or tissue samples from resting dogs. In contrast, five of six exercising dogs showed evidence of exercise-induced intrapulmonary arteriovenous shunting, as microspheres were detected in arterial blood and/or tissue. Furthermore, shunt magnitude was calculated to be 1.4 +/- 0.8% of cardiac output (n = 3). Evidence of intrapulmonary arteriovenous anastomoses was also found in three of four isolated lungs. Consistent with previous human findings, these data demonstrate that intrapulmonary arteriovenous pathways are functional in the dog and are recruited with exercise.

  10. A femoral arteriovenous shunt facilitates arterial whole blood sampling in animals

    International Nuclear Information System (INIS)

    Weber, Bruno; Burger, Cyrill; Buck, Alfred; Biro, Peter

    2002-01-01

    In this study we evaluated on-line continuous blood sampling in a femoral arteriovenous (a-v) shunt for use in quantitative tracer studies using gamma-emitting radionuclides in animals. The shunt consisted of 40 cm polyethylene tubing (PE-50) guided through a coincidence probe. Two three-way valves allowed blood pressure measurements and tracer injection. Blood flow in the shunt and the impulse response function (IRF) were assessed using heparinized human blood mixed with fluorine-18 fluorodeoxyglucose (FDG). In vivo experiments were performed in eight male rats (300-350 g) anaesthetized with halothane. In three rats, manual blood sampling was performed in parallel with on-line sampling. In another five animals, the arterial whole blood activity was recorded on-line for 40 min. For the experiments 150-180 MBq FDG was injected over 35 s. Blood flow in the shunt was 23.6, 29.2 and 42.8 ml/h at 100, 120 and 160 mmHg, respectively. The IRF was characterized by minimal dispersion (1-2 s FWHM). Deconvolution of the measured arterial input curves with the IRF changed the measured curve only minimally. Whole blood radioactivity concentration derived from manual and on-line sampling were in excellent agreement. The curves derived from on-line sampling were of high statistical quality. In conclusion, a femoral a-v shunt allows multiple manipulations such as measurement of the arterial whole blood activity, continuous blood pressure monitoring, injection of the tracer and collection of blood samples if necessary. It is not associated with blood loss if the collection of blood samples is not required. It is more convenient to use than manual sampling, the peak of the input curve is never missed and the input curves are of high statistical quality. (orig.)

  11. l-Arginine Pathway Metabolites Predict Need for Intra-operative Shunt During Carotid Endarterectomy

    DEFF Research Database (Denmark)

    Szabo, P; Lantos, J; Nagy, L

    2016-01-01

    lactate levels were increased during reperfusion (p = .02). The median pre-operative concentration of l-arginine was lower in patients requiring an intra-operative shunt than in patients without need of shunt (median: 30.3 μmol/L [interquartile range 24.4-34.4 μmol/L] vs. 57.6 μmol/L [interquartile range...

  12. Splenorenal shunt via magnetic compression technique: a feasibility study in canine and cadaver.

    Science.gov (United States)

    Xue, Fei; Li, Jianpeng; Lu, Jianwen; Zhu, Haoyang; Liu, Wenyan; Zhang, Hongke; Yang, Huan; Guo, Hongchang; Lv, Yi

    2016-12-01

    The concept of magnetic compression technique (MCT) has been accepted by surgeons to solve a variety of surgical problems. In this study, we attempted to explore the feasibility of a splenorenal shunt using MCT in canine and cadaver. The diameters of the splenic vein (SV), the left renal vein (LRV), and the vertical interval between them, were measured in computer tomography (CT) images obtained from 30 patients with portal hypertension and in 20 adult cadavers. The magnetic devices used for the splenorenal shunt were then manufactured based on the anatomic parameters measured above. The observation of the anatomical structure showed there were no special structural tissues or any important organs between SV and LRV. Then the magnetic compression splenorenal shunt procedure was performed in three dogs and five cadavers. Seven days later, the necrotic tissue between the two magnets was shed and the magnets were removed with the anchor wire. The feasibility of splenorenal shunt via MCT was successfully shown in both canine and cadaver, thus providing a theoretical support for future clinical application.

  13. Congenital hepatic arteriovenous fistula with intrahepatic portosystemic shunt and aortic stenosis in a dog

    International Nuclear Information System (INIS)

    Koide, K.; Koide, Y.; Wada, Y.; Nakaniwa, S.; Yamane, Y.

    2004-01-01

    Examination of a 2-month-old male golden retriever presented to the hospital revealed malnutrition, ascites, cardiac murmur and hyperammonemia. Identification of subaortic stenosis and hepatic arteriovenous fistula was made through ultrasonography and angiocardiography. In addition, intrasurgical mesenteric portography showed an intrahepatic portosystemic shunt. The dog did not show portal hypertension and secondary multiple extrahepatic portosystemic shunts. Surgical correction was attempted after medical treatment. The hepatic artery branch which was connected to the hepatic arteriovenous fistula was separated, and completely ligated using silk ligature. However, the separation of the intrahepatic shunt blood vessel was unsuccessful and the dog died 15 hr postoperatively

  14. Characterization of phosphorylated isocitrate dehydrogenase and purification of the isocitrate dehydrogenase kinase/phosphatase of Escherichia coli

    International Nuclear Information System (INIS)

    Malloy, P.J.

    1985-01-01

    NADP + -specific isocitrate dehydrogenase (IDH; EC 1.1.1.42) was shown to be phosphorylated with ( 32 P)-orthophosphate in vivo in several strains of Escherichia coli. In strain KC 13, an adenylate cyclase deficient mutant, the specific activity of IDH decreased 70% when acetate was added to stationary phase cultures grown on glucose. The enzyme was immunoprecipitated from sonic extracts and shown to contain 32 P by sodium dodecyl sulfate polyacrylamide gel electrophoresis and autoradiography. The results demonstrate that unlike many eukaryotic protein kinases, the protein kinase involved in the phosphorylation of IDH in E. coli does not require cyclic adenosine monophosphate for catalysis. Similarly, the phosphorylation of IDH was demonstrated in E. coli mutants deficient in either isocitrate lyase or malate synthase. The incorporation of 32 P in IDH was demonstrated following SDS-PAGE and autoradiography of the immunoprecipitated enzyme. These results suggest that the conditions required for the phosphorylation of IDH do not depend on the functioning of the glyoxylate shunt. Following in vivo 32 P-labeling of E. coli strain F143/KL259 in the presence of acetate, 32 P-labeled IDH was isolated from sonicated extracts of the cells. The 32 P-enzyme was carboxylmethylated and digested with trypsin. A single 32 P-labeled peptide was isolated from the tryptic digest. Amino acid analysis of the purified 32 P-labeled peptide showed that the peptide contains seven amino acids, including a single phosphorylated serine residue

  15. Nitrogen heat pipe for cryocooler thermal shunt

    International Nuclear Information System (INIS)

    Prenger F.C.; Hill, D.D.; Daney, D.E.

    1996-01-01

    A nitrogen heat pipe was designed, built and tested for the purpose of providing a thermal shunt between the two stages of a Gifford-McMahan (GM) cryocooler during cooldown. The nitrogen heat pipe has an operating temperature range between 63 and 123 K. While the heat pipe is in this temperature range during the system cooldown, it acts as a thermal shunt between the first and second stage of the cryocooler. The heat pipe increases the heat transfer to the first stage of the cryocooler, thereby reducing the cooldown time of the system. When the heat pipe temperature drops below the triple point, the nitrogen working fluid freezes, effectively stopping the heat pipe operation. A small heat leak between cryocooler stages remains because of axial conduction along the heat pipe wall. As long as the heat pipe remains below 63 K, the heat pipe remains inactive. Heat pipe performance limits were measured and the optimum fluid charge was determined

  16. Usefulness of color and pulsed Doppler's in the evaluation of surgical portosystemic shunts in pediatric patients; Utilidad del Doppler color y pulsado en la valoracion de los shunts portosistemicos quirurgicos en la edad pediatrica

    Energy Technology Data Exchange (ETDEWEB)

    Berrocal, T.; Prieto, C.; Cortes, P.; Rodriguez, R.; Pastor, I. [Hospital Universitario La Paz. Madrid (Spain)

    2003-07-01

    Portosystemic shunts are performed to relieve symptomatic portal hypertension symptomatic or removal pressure in hepatic vascularisation in patients with Budd-Chiari's syndrome. Most surgical portosystemic shunts can be suitably studied by means of ultrasound scan complemented by color and pulsed Dopplers, proved one understands the hemodynamics of the surgical procedures involved. This article demonstrates the usefulness and limitations of the ultrasound scan Duplex Doppler in the evaluation of portosystemic shunts performed on pediatric patients. Pulsed Doppler provides information regarding the nature and direction of blood flow. Color doppler is capable of directly revealing the shunt and, in most cases, permits the anastomosis to be located. The types of shunts that appear include proximal and distal spleno-renal, portocaval and mesocaval. Types of vascular connections are illustrated,s well as expected post-surgical blood flow direction in affected vessels. The ultrasound scanning technique is discussed, as well as the criteria for determining vascular permeability. Also highlighted are the advantages, limitations and diagnostic difficulties associated with the different forms of Doppler. (Author) 17 refs.

  17. Radionuclide Angiocardiographic Evaluation of Left-to-Right Cardiac Shunts: Analysis of Time-Active Curves

    International Nuclear Information System (INIS)

    Kim, Ok Hwa; Bahk, Yong Whee; Kim, Chi Kyung

    1987-01-01

    The noninvasive nature of the radionuclide angiocardiography provided a useful approach for the evaluation of left-to-right cardiac shunts (LRCS). While the qualitative information can be obtained by inspection of serial radionuclide angiocardiograms, the quantitative information of radionuclide angiocardiography can be obtained by the analysis of time-activity curves using advanced computer system. The count ratios method and pulmonary-to-systemic flow ratio (QP/QS) by gamma variate fit method were used to evaluate the accuracy of detection and localization of LRCS. One hundred and ten time-activity curves were analyzed. There were 46 LRCS (atrial septal defects 11, ventricular septal defects 22, patent ductus arteriosus 13) and 64 normal subjects. By computer analysis of time-activity curves of the right atriurn, ventricle and the lungs separately, the count ratios modified by adding the mean cardiac transit time were calculated in each anatomic site. In normal subjects the mean count ratios in the right atrium, ventricle and lungs were 0.24 on average. In atrial septal defects, the count ratios were high in the right atrium, ventricle and lungs, whereas in ventricular septal defects the count ratios were higher only in the right ventricle and lungs. Patent ductus arteriosus showed normal count ratios in the heart but high count ratios were obtained in the lungs. Thus, this count ratios method could be separated normal from those with intracardiac or extracardiac shunts, and moreover, with this method the localization of the shunt level was possible in LRCS. Another method that could differentiate the intracardiac shunts from extracardiac shunts was measuring QP/QS in the left and right lungs. In patent ductus arteriosus, the left lung QP/QS was higher than those of the right lung, whereas in atrial septal defects and ventricular septal defects QP/ QS ratios were equal in both lungs. From this study, it was found that by measuring QP/QS separately in the lungs

  18. The clinical application and nursing experience of adjustable shunt valve in treatment for patients with normal pressure hydrocephalus

    Directory of Open Access Journals (Sweden)

    YANG Li-rong

    2012-02-01

    Full Text Available Objective To introduce the application of adjustable shunt valve in treatment for patients with normal pressure hydrocephalus. Methods Twenty-four patients with normal pressure hydrocephalus implanted adjustable shunt valve underwent ventriculo-peritoneal shunt surgery and nursing care. Results After operation, cerebrospinal pressure was regulated for 0-6 (1.88 ± 1.52 times. Clinical symptoms were improved, especially in gait disturbance. Conclusion Treatment of normal pressure hydrocephalus with adjustable shunt valve can alleviate symptoms of hydrocephalus. It is especially suitable for patients with short course and secondary normal hydrocephalus patients.

  19. Systemic Arterial-to-Pulmonary Artery Shunt Utilization

    African Journals Online (AJOL)

    multiruka1

    In certain circumstances, such as cyanotic neonates with tetralogy of Fallot (4) or cyanotic patients with. Tetralogy of Fallot and hypoplastic pulmonary arteries. (5), better outcomes are obtained if definitive surgery. (total correction or palliation) is preceded by creation of a systemic arterial-to-pulmonary artery shunt (SAPAS).

  20. Controlling chaos in RCL-shunted Josephson junction by delayed linear feedback

    International Nuclear Information System (INIS)

    Feng Yuling; Shen Ke

    2008-01-01

    The resistively-capacitively-inductively-shunted (RCL-shunted) Josephson junction (RCLSJJ) shows chaotic behaviour under some parameter conditions. Here a scheme for controlling chaos in the RCLSJJ is presented based on the linear feedback theory. Numerical simulations show that this scheme can be effectively used to control chaotic states in this junction into stable periodic states. Moreover, the different stable period states with different period numbers can be obtained by appropriately adjusting the feedback intensity and delay time without any pre-knowledge of this system required

  1. Right-to-left shunt may be prone to affect the white matter integrity of posterior circulation in migraine without aura.

    Science.gov (United States)

    Xie, Hui; Bian, Yitong; Jian, Zhijie; Huo, Kang; Liu, Rui; Zhu, Dan; Zhang, Lihui; Wu, Jun; Yang, Jian; Liu, Jixin; Luo, Guogang

    2018-01-01

    Numerous studies have indicated an association between migraine and right-to-left shunt. However, little is known about whether right-to-left shunt has an effect on the migraine brain. This observational study aims to explore the impact of right-to-left shunt on the brain of migraine without aura on microstructural level. Thirty-five patients with migraine without aura were enrolled in this study. Contrast-enhanced Transcranial Doppler was performed to evaluate the status of right-to-left shunt. Three-dimensional T1-weighted and diffusion tensor images were acquired for data analysis. We employed voxel-based morphometry and tract-based spatial statistical analyses to assess the differences of gray and white matter between migraineurs with and without right-to-left shunt, respectively. Among the 35 patients, 19 (54.3%) patients had right-to-left shunt. There were no significant differences in headache features between migraineurs with and without right-to-left shunt. There were significant increases of mean and radial diffusivity in migraineurs with right-to-left shunt compared with migraineurs without right-to-left shunt. The alterations were primarily located in the right posterior thalamic radiation, secondly in the body of corpus callosum and the right superior corona radiata. No significant differences were observed in values of fractional anisotropy and axial diffusivity. No significant between-group differences were found in gray matter volume. Right-to-left shunt may cause alterations of white matter integrity in migraine without aura, and the alterations are more likely to be located at the posterior circulation.

  2. ald of Mycobacterium tuberculosis Encodes both the Alanine Dehydrogenase and the Putative Glycine Dehydrogenase

    Science.gov (United States)

    Giffin, Michelle M.; Modesti, Lucia; Raab, Ronald W.; Wayne, Lawrence G.

    2012-01-01

    The putative glycine dehydrogenase of Mycobacterium tuberculosis catalyzes the reductive amination of glyoxylate to glycine but not the reverse reaction. The enzyme was purified and identified as the previously characterized alanine dehydrogenase. The Ald enzyme was expressed in Escherichia coli and had both pyruvate and glyoxylate aminating activities. The gene, ald, was inactivated in M. tuberculosis, which resulted in the loss of all activities. Both enzyme activities were found associated with the cell and were not detected in the extracellular filtrate. By using an anti-Ald antibody, the protein was localized to the cell membrane, with a smaller fraction in the cytosol. None was detected in the extracellular medium. The ald knockout strain grew without alanine or glycine and was able to utilize glycine but not alanine as a nitrogen source. Transcription of ald was induced when alanine was the sole nitrogen source, and higher levels of Ald enzyme were measured. Ald is proposed to have several functions, including ammonium incorporation and alanine breakdown. PMID:22210765

  3. Clinical results of the transjugular intrahepatic portosystemic shunt

    Energy Technology Data Exchange (ETDEWEB)

    Park, Auh Whan; Sim, Jae In; Ryeom, Hun Kyu; Kim, Yong Joo [Kyungpook National University Hospital, Daegu (Korea, Republic of)

    1994-04-15

    To evaluate the clinical results of transjugular intrahepatic portosystemic shunt(TIPS) for the control of variceal bleeding. TIPS creation was attempted in 23 patients with endoscopically confirmed variceal bleeding. Most patients had multiple episodes of bleeding in the past and have been treated with multiple endoscopic sclerotherapies. Pre-and post-procedural hepatic and portal vein pressures were measured. After creation of TIPS patients were followed up at regular intervals. TIPS has been successfully accomplished in 22 of 23 patients using Wallstent(n = 21) and Strecker stent(n = 1). Immediate bleeding control was achieved in all patients with shunt creation. No procedure-related complication was noted. Portal vein pressure was reduced from 30.7 {+-} 5.8 mmHg to 20.8 {+-} 4.7 mmHg. The mean pressure gradient of portosystemic shunt dropped from 22.8 {+-} 6.0 prior to TIPS to 12.2 {+-} 4.1 immediately after. During the follow-up period (6-556 days, mean; 10 months), seven patients died; progressive hepatic failure (n 4), variceal rebleeding (n = 2), and respiratory failure(n = 1). Hepatic encephalopathy after TIPS was noted in 7 patients(31.8%). Variceal rebleeding occurred in 3 patients(13.6%). The remaining 15 patients have survived an average of 11 months. This results suggest that TIPS is a safe and effective method for lowering portal pressure and controlling variceal bleeding. Furthermore if these initial results are encouraged by further long-term observation, TIPS could replace endoscopic and risky surgical intervention.

  4. Spontaneous resolution of splenic infarcts after distal splenorenal shunt in children with extra hepatic portal venous obstruction: Our experience

    Directory of Open Access Journals (Sweden)

    Arbinder Kumar

    2014-01-01

    Full Text Available Background: In cases of portal hypertension with splenic infarcts, splenectomy with proximal splenorenal shunt has been recommended. We are sharing our experience with distal splenorenal shunt in these cases contrary to the popular belief. Materials and Methods: Splenic infarcts were graded as mild, moderate and severe according to the pre-operative CT portogram. Mild, moderate and severe infarcts were defined as an infarct involving 50% area of the spleen, respectively. Mild and moderate infarcts were managed by spleen-preserving distal splenorenal shunt while those with extensive infarcts were subjected to splenectomy and proximal splenorenal shunt. Those with spleen-preserving shunts were closely followed in the post-operative period according to a uniform protocol. Clinical examination was regularly done to assess the size of the spleen and note the presence of pain, tenderness in the left intercostal space. An ultrasound Doppler was done after 7 days to assess shunt patency while CT portogram was repeated at 6 monthly intervals. Results: Fourteen cases with splenic infarcts formed the study group. Eight cases had mild infarcts, 3 had moderate infarcts and 3 had severe infarcts. Four underwent proximal splenorenal shunt, and 10 underwent warren′s shunt (8 with mild and 2 with moderate infarcts. In 9/10 (90%, spleen could eventually be retained. Spleen completely regressed in them and so did the infarct. Conclusions:Spleen-preserving distal splenorenal shunt can be considered as a viable option in the management of cases with mild and carefully selected moderate splenic infarcts.

  5. Scrotal migration of ventriculoperitoneal shunt: a case report at Haji Adam Malik hospital, Medan

    Science.gov (United States)

    Dharmajaya, R.

    2018-03-01

    Ventriculoperitoneal (VP) shunting is one of the most common pediatric neurosurgery operations performed for dealing with hydrocephalus. We report an unusual case of a 1-year-old child with communicating hydrocephalus, who experienced right scrotum swelling after 11 months of shunting. Abdominal x-ray showed the shunt tubing, which was kinked in its distal portion of thescrotum. Ultrasound examination was performed, revealing hydrocele along with the presence of thedistal catheter in the scrotum. The patient underwent distal catheter trimming via laparoscopic approach with general surgery and managed with asuccessful outcome. Prompt surgical management of catheter repositioning is recommended to avoid the risk of further complications.

  6. The design and implementation of on-line monitoring system for UHV compact shunt capacitors

    Science.gov (United States)

    Tao, Weiliang; Ni, Xuefeng; Lin, Hao; Jiang, Shengbao

    2017-08-01

    Because of the large capacity and compact structure of the UHV compact shunt capacitor, it is difficult to take effective measures to detect and prevent the faults. If the fault capacitor fails to take timely maintenance, it will pose a threat to the safe operation of the system and the life safety of the maintenance personnel. The development of UHV compact shunt capacitor on-line monitoring system can detect and record the on-line operation information of UHV compact shunt capacitors, analyze and evaluate the early fault warning signs, find out the fault capacitor or the capacitor with fault symptom, to ensure safe and reliable operation of the system.

  7. Cine-MR imaging aqueductal CSF flow in normal pressure hydrocephalus syndrome before and after CSF shunt

    International Nuclear Information System (INIS)

    Mascalchi, M.; Arnetoli, G.; Inzitari, D.; Dal Pozzo, G.; Lolli, F.; Caramella, D.; Bartolozzi, C.

    1993-01-01

    Reproducibility of the aqueductal CSF signal intensity on a gradient echo cine-MR sequence exploiting through plane inflow enhancement was tested in 11 patients with normal or dilated ventricles. Seven patients with normal pressure hydrocephalus (NPH) syndrome were investigated with the sequence before and after CSF shunting. Two patients exhibiting central flow void within a hyperintense aqueductal CSF improved after surgery and the flow void disappeared after shunting. One patient with increased maximum and minimum aqueductal CSF signal as compared to 18 healthy controls also improved and the aqueductal CSF signal was considerably decreased after shunting. Three patients with aqueductal CSF values similar to those in the controls did not improve, notwithstanding their maximum aqueductal CSF signals decreasing slightly after shunting. No appreciable aqueductal CSF flow related enhancement consistent with non-communicating hydrocephalus was found in the last NPH patient who improved after surgery. Cine-MR with inflow technique yields a reproducible evaluation of flow-related aqueductal CSF signal changes which might help in identifying shunt responsive NPH patients. These are likely to be those with hyperdynamic aqueductal CSF or aqueductal obstruction. (orig.)

  8. Usefulness of color and pulsed Doppler's in the evaluation of surgical portosystemic shunts in pediatric patients

    International Nuclear Information System (INIS)

    Berrocal, T.; Prieto, C.; Cortes, P.; Rodriguez, R.; Pastor, I.

    2003-01-01

    Portosystemic shunts are performed to relieve symptomatic portal hypertension symptomatic or removal pressure in hepatic vascularisation in patients with Budd-Chiari's syndrome. Most surgical portosystemic shunts can be suitably studied by means of ultrasound scan complemented by color and pulsed Dopplers, proved one understands the hemodynamics of the surgical procedures involved. This article demonstrates the usefulness and limitations of the ultrasound scan Duplex Doppler in the evaluation of portosystemic shunts performed on pediatric patients. Pulsed Doppler provides information regarding the nature and direction of blood flow. Color doppler is capable of directly revealing the shunt and, in most cases, permits the anastomosis to be located. The types of shunts that appear include proximal and distal spleno-renal, portocaval and mesocaval. Types of vascular connections are illustrated,s well as expected post-surgical blood flow direction in affected vessels. The ultrasound scanning technique is discussed, as well as the criteria for determining vascular permeability. Also highlighted are the advantages, limitations and diagnostic difficulties associated with the different forms of Doppler. (Author) 17 refs

  9. Alteration of brain viscoelasticity after shunt treatment in normal pressure hydrocephalus

    Energy Technology Data Exchange (ETDEWEB)

    Freimann, Florian Baptist; Sprung, Christian [Charite - University Medicine Berlin, Campus Virchow-Klinikum, Neurosurgical Department, Berlin (Germany); Streitberger, Kaspar-Josche; Klatt, Dieter; Sack, Ingolf [Charite - University Medicine Berlin, Campus Charite Mitte, Department of Radiology, Berlin (Germany); Lin, Kui; McLaughlin, Joyce [Rensselaer Polytechnic Institute, Mathematics Department, Troy, NY (United States); Braun, Juergen [Charite - University Medicine Campus Benjamin Franklin, Institute of Medical Informatics, Berlin (Germany)

    2012-03-15

    Normal pressure hydrocephalus (NPH) represents a chronic neurological disorder with increasing incidence. The symptoms of NPH may be relieved by surgically implanting a ventriculoperitoneal shunt to drain excess cerebrospinal fluid. However, the pathogenesis of NPH is not yet fully elucidated, and the clinical response of shunt treatment is hard to predict. According to current theories of NPH, altered mechanical properties of brain tissue seem to play an important role. Magnetic resonance elastography (MRE) is a unique method for measuring in vivo brain mechanics. In this study cerebral MRE was applied to test the viscoelastic properties of the brain in 20 patients with primary (N = 14) and secondary (N = 6) NPH prior and after (91 {+-} 16 days) shunt placement. Viscoelastic parameters were derived from the complex modulus according to the rheological springpot model. This model provided two independent parameters {mu} and {alpha}, related to the inherent rigidity and topology of the mechanical network of brain tissue. The viscoelastic parameters {mu} and {alpha} were found to be decreased with -25% and -10%, respectively, compared to age-matched controls (P < 0.001). Interestingly, {alpha} increased after shunt placement (P < 0.001) to almost normal values whereas {mu} remained symptomatically low. The results indicate the fundamental role of altered viscoelastic properties of brain tissue during disease progression and tissue repair in NPH. Clinical improvement in NPH is associated with an increasing complexity of the mechanical network whose inherent strength, however, remains degraded. (orig.)

  10. Alteration of brain viscoelasticity after shunt treatment in normal pressure hydrocephalus

    International Nuclear Information System (INIS)

    Freimann, Florian Baptist; Sprung, Christian; Streitberger, Kaspar-Josche; Klatt, Dieter; Sack, Ingolf; Lin, Kui; McLaughlin, Joyce; Braun, Juergen

    2012-01-01

    Normal pressure hydrocephalus (NPH) represents a chronic neurological disorder with increasing incidence. The symptoms of NPH may be relieved by surgically implanting a ventriculoperitoneal shunt to drain excess cerebrospinal fluid. However, the pathogenesis of NPH is not yet fully elucidated, and the clinical response of shunt treatment is hard to predict. According to current theories of NPH, altered mechanical properties of brain tissue seem to play an important role. Magnetic resonance elastography (MRE) is a unique method for measuring in vivo brain mechanics. In this study cerebral MRE was applied to test the viscoelastic properties of the brain in 20 patients with primary (N = 14) and secondary (N = 6) NPH prior and after (91 ± 16 days) shunt placement. Viscoelastic parameters were derived from the complex modulus according to the rheological springpot model. This model provided two independent parameters μ and α, related to the inherent rigidity and topology of the mechanical network of brain tissue. The viscoelastic parameters μ and α were found to be decreased with -25% and -10%, respectively, compared to age-matched controls (P < 0.001). Interestingly, α increased after shunt placement (P < 0.001) to almost normal values whereas μ remained symptomatically low. The results indicate the fundamental role of altered viscoelastic properties of brain tissue during disease progression and tissue repair in NPH. Clinical improvement in NPH is associated with an increasing complexity of the mechanical network whose inherent strength, however, remains degraded. (orig.)

  11. [A case of non-traumatic tension pneumocephalus 12 years after initial ventriculo-peritoneal shunt].

    Science.gov (United States)

    Idei, Masaru; Yamane, Kanji; Okita, Shinji; Kumano, Kiyoshi; Nakae, Ryuta; Nishizawa, Shigeru

    2009-10-01

    The authors presented a patient with non-traumatic tension pneumocephalus 12 years after initial ventriculo-peritoneal shunt. A 60-year-old man had a past history of subarachnoid hemorrhage. At ÿtime, he underwent clipping surgery and emplacement of a ventriculoperitoneal shunt with a low pressure valve, and was discharged from hospital in a bedridden condition. After 12 years, he was transferred to our hospital because of dysarthria and right hemiparesis. On admission, he had multiple dimples of the scalp in the left frontal area where craniotomy had been carried out 12 years before. Head CT scan revealed air located mainly in bilateral subdural space and collapsed ventricles. We suspected that he had a tension pneumocephalus through a scalp-subdural fistula induced by long-term low intracranial pressure. Operation for closure of the fistula was intended. During the operation a subdural abscess was found so, artificial bone and the shunt system was removed. We were able to detect the fistula from the defect of the scalp to the subdural space and closed it by repairing a scalp defect, using dural plasty. Postoperative clinical course was uneventful and the patient was discharged. About 6 month after the operation, cranioplasty and lumbo-peritoneal shunt was performed. We must recognize that appropriate management of intracranial pressure after installation of a ventriculo-peritoneal shunt is necessary for prevention of tension pneumocephalus.

  12. Complications of ventriculoperitoneal shunt in hydrocephalic children

    African Journals Online (AJOL)

    These children were treated at the Department of Pediatric Surgery, Dr. Behc¸et Uz Children's Hospital, and at the Department of Neurosurgery, Tepecik Training Hospital. Management of these patients with special emphasis on the literature pertaining to the migration of shunt catheters into the scrotum is reviewed and ...

  13. Shunt and series resistance of photovoltaic module evaluated from the I-V curve; I-V tokusei kara hyokashita taiyo denchi no shunt teiko to chokuretsu teiko

    Energy Technology Data Exchange (ETDEWEB)

    Asano, K; Kawamura, H; Yamanaka, S; Kawamura, H; Ono, H [Meijo University, Nagoya (Japan)

    1997-11-25

    With an objective of discussing I-V characteristics when a shadow has appeared on part of a photovoltaic module, evaluations were given as a first stage of the study on saturation current, shunt resistance and series resistance for the solar cell module. As a result of measuring change in amount of power generated in a sunny day with a shadow appearing over the solar cell module, reduction in power generation capability of about 23% was verified. In other words, the I-V characteristics of the solar cell module change largely because of existence of the shadow caused on the module. The I-V characteristics curve may be expressed and calculated as a function of the shunt resistance and series resistance. By curve-fitting measurement data for a case of changing insolation without existence of partial shadow, values of the shunt resistance and series resistance were derived. As a result, it was found that the calculations agree well with measurements. It was made also clear that each parameter shows temperature dependence. 6 refs., 10 figs., 1 tab.

  14. Quantitation of the intrahepatic shunt index by injection of 99mTc-macroaggregated albumin into the spleen

    International Nuclear Information System (INIS)

    Saito, Masaaki; Ohnishi, Kunihiko; Katsurai, Hiroshi; Tanaka, Hideo; Chin, Nobuyoshi; Iida, Shinji; Nomura, Fumio; Okuda, Kunio

    1987-01-01

    The accuracy of the intrahepatic shunt index measured by injection of 99m Tc-macroaggregated albumin into the spleen was assessed in comparison with the intrahepatic shunt index measured by injection of 99m Tc-macroaggregated albumin into the portal trunk in 28 patients with portal hypertension. 99m Tc-macroaggregated albumin was injected through the catheter into the portal trunk and the intrahepatic shunt index was calculated by counting over predetermined areas of the liver and lungs. Injection of 99m Tc-macroaggregated albumin into the spleen was performed between one or two weeks before portal vein catheterization, and the calculation of the intrahepatic shunt index was performed with a scinticamera and ROI-radiograms obtained by data-processing. There was a significant correlation between the intrahepatic shunt index calculated by injection of 99m Tc-macroaggregated albumin into the spleen and that by injection of 99m Tc-macroaggregated albumin into the portal trunk (r = 0.90, p < 0.001). (author)

  15. Incidence of ischemic lesions by diffusion-weighted imaging after carotid endarterectomy with routine shunt usage

    International Nuclear Information System (INIS)

    Inoue, Tomohiro; Tsutsumi, Kazuo; Adachi, Shinobu; Tanaka, Shota; Yako, Kyoko; Saito, Kuniaki; Kunii, Naoto; Maeda, Keiitirou

    2006-01-01

    Temporary intraluminal shunt was used during 72 consecutive carotid endarterectomies (CEAs) in 61 patients (bilateral CEA in 11 patients) during October 2001 and September 2005. The medical records of these patients were retrospectively reviewed. All procedures were performed with routine shunt insertion without monitoring such as electroencephalography. Pre- and postoperative diffusion-weighted magnetic resonance (MR) imaging was used to detect ischemic complications. Postoperative angiography was performed in 70 cases to detect abnormalities such as major stenosis or dissection of the distal end. Symptomatic ischemic complication occurred in one patient at 1 month. Postoperative diffusion-weighted MR imaging detected new hyperintense lesions in three patients including the symptomatic patient. Postoperative angiography confirmed that the distal end was satisfactory in all cases. The incidence of ischemic lesions of embolic origin after CEA with routine shunt usage is acceptably low if the procedure of shunt device insertion and removal is meticulously conducted. (author)

  16. Analysis and control of a shunt active power filter

    Energy Technology Data Exchange (ETDEWEB)

    Ottersten, R.; Petersson, Andreas [Chalmers Univ. of Technology, Goeteborg (Sweden). Dept. of Electric Power Engineering

    1999-09-01

    This report deals with active power filtering of low-frequency current harmonics. The active filter consists of a forced-commutated voltage source inverter with a digital control system. The aim of this master thesis is to investigate the performance of a shunt active power filter, and the parameters influence on the system performance. Three different harmonic identification methods are presented and compared. The shunt active power filter is very well suited for harmonic current reduction, provided that the phase shift due to the digital implementation of the control system is compensated. The performance of the active power filter depends on the switching frequency. When using individual harmonic detection methods the amount of compensation can be fully controlled for each current harmonic.

  17. Use of transsplenic injection of agitated saline and heparinized blood for the ultrasonographic diagnosis of macroscopic portosystemic shunts in dogs.

    Science.gov (United States)

    Gómez-Ochoa, Pablo; Llabrés-Díaz, Francisco; Ruiz, Sergio; Corda, Andrea; Prieto, Saul; Sosa, Ivan; Gregori, Tommaso; Gascón, Manuel; Couto, Guillermo C

    2011-01-01

    We describe the use of ultrasonography-guided percutaneous splenic injection of agitated saline and heparinized blood for the diagnosis of portosystemic shunts (PSS) in 34 dogs. Agitated saline mixed with 1 ml of heparinized autologous blood was injected into the spleen of 34 sedated dogs under sonographic guidance. The transducer was then sequentially repositioned to visualize the portal vein, the caudal vena cava, and the right atrium through different acoustic windows. It was possible to differentiate between intrahepatic and extrahepatic shunts depending on the entry point of the microbubbles into the caudal vena cava. Portoazygos shunts and portocaval shunts could be differentiated based on the presence of microbubbles in the caudal vena cava and/or the right atrium. In one dog, collateral circulation due to portal hypertension was identified. In dogs with a single extrahepatic shunt, the microbubbles helped identify the shunting vessel. The technique was also used postoperatively to assess the efficacy of shunt closure. All abnormal vessels were confirmed by exploratory laparotomy or with ultrasonographic identification of the shunting vessel. Ultrasound-guided transsplenic injection of agitated saline with heparinized blood should be considered as a valuable technique for the diagnosis of PSS; it is easy to perform, safe, and the results are easily reproducible.

  18. Broadband transmission noise reduction of smart panels featuring piezoelectric shunt circuits and sound-absorbing material.

    Science.gov (United States)

    Kim, Jaehwan; Lee, Joong-Kuen

    2002-09-01

    The possibility of a broadband noise reduction of piezoelectric smart panels is experimentally studied. A piezoelectric smart panel is basically a plate structure on which piezoelectric patches with electrical shunt circuits are mounted and sound-absorbing material is bonded on the surface of the structure. Sound-absorbing material can absorb the sound transmitted at the midfrequency region effectively while the use of piezoelectric shunt damping can reduce the transmission at resonance frequencies of the panel structure. To be able to reduce the sound transmission at low panel resonance frequencies, piezoelectric damping using the measured electrical impedance model is adopted. A resonant shunt circuit for piezoelectric shunt damping is composed of resistor and inductor in series, and they are determined by maximizing the dissipated energy through the circuit. The transmitted noise-reduction performance of smart panels is tested in an acoustic tunnel. The tunnel is a square cross-sectional tube and a loudspeaker is mounted at one side of the tube as a sound source. Panels are mounted in the middle of the tunnel and the transmitted sound pressure across panels is measured. When an absorbing material is bonded on a single plate, a remarkable transmitted noise reduction in the midfrequency region is observed except for the fundamental resonance frequency of the plate. By enabling the piezoelectric shunt damping, noise reduction is achieved at the resonance frequency as well. Piezoelectric smart panels incorporating passive absorbing material and piezoelectric shunt damping is a promising technology for noise reduction over a broadband of frequencies.

  19. Progressive Functional Underdrainage in Cerebrospinal Fluid Shunt-Dependent Women During Pregnancy: Case Report and Review of the Literature.

    Science.gov (United States)

    Krauss, Philipp; Fritz-Naville, Marco; Regli, Luca; Stieglitz, Lennart Henning

    2018-01-01

    Since the 1950s cerebrospinal fluid (CSF) shunt dependency has no longer been a contradiction to normal life, including sexuality and pregnancy in women, because of advances in the understanding of hydrocephalus and shunt technology. Although pregnancy in shunt-dependent women is rare, it causes uncertainty among treating physicians. We report the case of a 34-year-old pregnant woman with a ventriculoperitoneal shunt. Throughout her pregnancy she experienced progressive symptoms of CSF underdrainage without any signs of other pregnancy-related complications. After the delivery of a healthy infant, shunt resistance had to be readjusted to prepregnancy levels. A comprehensive review of the literature reports in English, listed in PubMed, is provided. Conservative treatment of pregnancy-related functional underdrainage by consecutive valve pressure adjustment is possible, easy, and safe. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Experimental study of an endothelial progenitor cell coated stent in transjugular intrahepatic portosystemic shunt

    International Nuclear Information System (INIS)

    Shi Hongjian; Teng Gaojun; Cao Aihong; Chen Jun; Deng Gang

    2009-01-01

    Objective: To evaluate the efficacy of a self-expandable metal stent coated with autologous endothelial progenitor cells (EPCs) for prevention of restenosis in transjugular intrahepatic portosystemic shunt (TIPS) in a swine model. Methods: EPCs were coated on the metal stents using fibrin gel before TIPS procedure. TIPS was performed in 15 young adult pigs, using an autologous EPC-seeded stent (treatment group, n=9) or a conventional bare metal stent (control group, n=6). All pigs were sacrificed at 2 weeks after TIPS procedure. Portography was performed immediately before the euthanasia. Gross and microscopic pathological exams and immunohistochemical exams of the TIPS track specimens were performed. Fisher test and t test were used to analyse the data. Results: TIPS was performed successfully in all the 15 swine. On day 14 of follow-up, direct portography and necropsy demonstrated that 5 shunts remained patent, 2 shunts stenosed, and the remaining 2 shunts occluded in the treatment group (n=9); while 5 shunts were occluded and one shunt was stenotic in the control group (n=6). The patency rate was 56% vs 0 (P=0.03) between the two groups. Histological analyses showed a greater pseudo-intimal hyperplasia in the TIPS track of the control group than that of the treatment group (pseudointimal thickness at hepatic vein, hepatic parenchyma and portal vein site was (1.2±0.4), (1.3±0.5), (1.5±0.4) mm vs (1.0±0.6), (0.9±0.5), (1.0±0.4) mm respectively (P<0.05). Conclusion: The EPC-coated metal stent is feasibly constructed in vitro and improves the patency in TIPS in a porcine model. (authors)

  1. Barry shunt for treatment of a 76-hour stuttering priapism without subsequent erectile dysfunction

    Directory of Open Access Journals (Sweden)

    Osmonov DK

    2014-07-01

    Full Text Available Daniar Kurmanbekovich Osmonov, Aleksey Aksenov, Andrea Nathaly Guerra Sandoval, Almut Kalz, Klaus Peter Juenemann Department of Urology and Pediatric Urology, University Hospital Schleswig-Holstein, Campus Kiel, Kiel, Germany Introduction: This paper reports treatment of a 76-hour low-flow priapism with a shunting procedure that was first described by Barry in 1976. We were able to observe the preservation of erectile function despite the long period of ischemia. A review of the literature shows that there are few reports of erectile function recovery after a priapism of similar duration. Materials and methods: A 42-year-old patient presented with a 76-hour priapism, probably caused by consumption of alcohol and illegal drugs. A Barry Shunt procedure was performed. The erectile function of the patient was assessed by means of International Index of Erectile Function score over a follow-up period of 30 months. Moreover, we reviewed different surgical options for treatment of priapism in the literature. Results: Partial return of erection without sexual arousal occurred on two occasions during the 10-day hospitalization, but was treated by manipulation of the penis, ie, by milking the tumescence into the shunt. After 3 months, the shunt was still palpable as a subcutaneous swelling. Six months postoperatively, the residual swelling had disappeared. The International Index of Erectile Function score was of 21 without phosphodiesterase type 5 inhibitors after a follow-up of 2.5 years. Conclusion: Barry shunt is an effective alternative surgical option for the treatment of low-flow priapism. In the case of our patient, it was also effective after a 76-hour-lasting priapism. Keywords: low flow priapism, erectile function, cavernovenous shunt, surgical treatment of stuttering priapism

  2. Analysis of postural sway in patients with normal pressure hydrocephalus: effects of shunt implantation

    Directory of Open Access Journals (Sweden)

    Czerwosz L

    2009-12-01

    Full Text Available Abstract Poor postural balance is one of the major risk factors for falling in normal pressure hydrocephalus (NPH. Postural instability in the clinic is commonly assessed based upon force platform posturography. In this study we focused on the identification of changes in sway characteristics while standing quiet in patients with NPH before and after shunt implantation. Postural sway area and sway radius were analyzed in a group of 9 patients and 46 controls of both genders. Subject's spontaneous sway was recorded while standing quiet on a force platform for 30-60 s, with eyes open and then closed. Both analyzed sway descriptors identified between-group differences and also an effect of shunt implantation in the NPH group. Sway radius and sway area in patients exhibited very high values compared with those in the control group. Importantly, the effect of eyesight in patients was not observed before shunt implantation and reappeared after the surgical treatment. The study documents that static force platform posturography may be a reliable measure of postural control improvement due to shunt surgery.

  3. [Application of degree of portal systemic shunting in assessing upper gastrointestinal bleeding in patients with schistosomiasis cirrhosis].

    Science.gov (United States)

    Shuai, Ju; Ying, Li; Chang-Xue, Ji; Biao, Zhang

    2017-03-27

    To discuss the application of the degree of portal systemic shunting in assessing the upper gastrointestinal bleeding in patients with hepatic schistosomiasis. Thirty-three patients with upper gastrointestinal bleeding caused by hepatic schistosomiasis (a bleeding group) and 29 schistosomiasis cirrhosis patients without bleeding (a non-bleeding group) were enrolled as investigation subjects in Jinshan Hospital. The subjects were scanned by the 128 abdominal slice spiral CT. The portal systemic shunting vessels were reconstructed by using thin slab maximum intensity projection (TSMIP) and multiplanar reconstruction (MPR). The degrees of the shunting vessels of the subjects were evaluated and compared, and the relationship between upper gastrointestinal bleeding and the degree of the shunting was analyzed. In the bleeding group, the occurrence rates of the shunting vessels were found as follows: 86.4% in left gastric varices, 68.2% in short gastric varices, 50.0% in esophageal varices, 50.0% in para-esophageal varices, 37.9% in gastric varices, 69.7% in gastric-renal varices, 51.5% in spleen-renal varices, 25.8% in abdominal wall varices, 15.2% in omentum varices, 63.6% in para-splenic varices, 34.8% in umbilical varices, 40.9% in retroperitoneal-paravertebral varices, and 36.4% in mesenteric varices. In the bleeding group, the occurrence rates and the degree of shunt were significantly higher than those in the non-bleeding group in esophageal varices, esophageal vein, left gastric vein and gastric varices (all P upper gastrointestinal bleeding in patients with hepatic schistosomiasis. The patents with higher degree of the shunting vessels have a higher risk of gastrointestinal bleeding.

  4. A new electromagnetic shunt damping treatment and vibration control of beam structures

    International Nuclear Information System (INIS)

    Niu Hongpan; Zhang Xinong; Xie Shilin; Wang Pengpeng

    2009-01-01

    In this paper a new class of shunted electromagnetic damping treatment is proposed: a non-contact electromagnetic shunt damper (NC-EMSD). The NC-EMSD consists of an electromagnet attached to a host structure, a permanent magnet attached to the fixed boundary and an electrical impedance connected to the terminals of the electromagnet. The electromagnet and the shunt impedance constitute a closed circuit. When the structure vibrates, an induced electromotive force will be produced and results in the electromagnetic force as damping force, which can suppress the vibration of the structure. The model of NC-EMSD is built up based on the equivalent current method. The governing equations of the beam with NC-EMSD are established using Hamilton's principle. The capacitor-matching-inductance (CMI) method and the negative resistive capacitor-matching-inductance (NR-CMI) method are proposed, respectively. Then the vibration control of a cantilever beam with NC-EMSD is simulated and measured by CMI and NR-CMI control methods, respectively. The results show that both the CMI and NR-CMI can attenuate the vibration effectively, and the NR-CMI provides much better control performance than that by CMI. It is indicated as well from the studies that the decrease of either the gap between the magnet pair or the resistance of the shunt impedance contributes to the improvement of control performance

  5. US and angiographic examination of brachial dialysis shunts

    International Nuclear Information System (INIS)

    Langer, R.; Langer, M.F.J.; Zwicker, C.; Wakat, J.P.; Treisch, J.

    1988-01-01

    In an experimental study, 13 bypass grafts and eight patches were evaluated. With PTFE-Vitagraft, IMPRA, and Microvel Haemashield grafts total reflection occurred, so that these grafts are not suitable for ultrasound (US) examination. In a prospective clinical trial 40 patients were examined with intraarterial digital subtraction angiography (DSA) and US of the hemodialysis shunts; for DSA, a contrast material with 150 mg/mL of iodine was used. The image quality was excellent in all cases, and no sensation of pain was reported, only a mild sensation of warmth during the injection. The evaluation of image quality for the sonographic investigation showed the following results: shunt artery, 74% excellent, 17% good, and 9% nondiagnostic; anastomosis, 70% excellent, 26% good, and 4% nondiagnostic; draining vein, 91% excellent and 9% good. US is a suitable screening procedure, and DSA can be performed preoperatively without major discomfort and with excellent image quality

  6. Management of intracranial dural arteriovenous shunts in adults

    International Nuclear Information System (INIS)

    Sarma, Dipanka; Brugge, Karel ter

    2003-01-01

    Dural arteriovenous shunts are abnormal arteriovenous communications within the dura. They are thought to be an acquired condition in adults and can present with a variety of clinical features, ranging from benign bruits to intracranial hemorrhage and neurological deficits. The presentation and natural history of these shunts is largely determined by the pattern of venous drainage. Knowledge of natural history and careful study of the angioarchitexture by angiography is therefore mandatory for correct management of these lesions. In this review, principles of management in adults and the various factors that influence treatment decisions are discussed, with a focus on endovascular therapy. Retrograde leptomeningeal or cortical venous drainage has a strong correlation with adverse clinical events and the requirement for aggressive management in this situation is highlighted. Indications for endovascular treatment, therapeutic goals, approaches and techniques are reviewed. The role of surgical treatment is also briefly discussed

  7. Evaluation of hepatic steatosis in dogs with congenital portosystemic shunts using Oil-Red-O staining

    Science.gov (United States)

    Hunt, GB; Luff, J; Daniel, L; Van den Bergh, R.

    2015-01-01

    The aims of this prospective study were to quantify steatosis in dogs with congenital portosystemic shunts using a fat-specific stain, to compare the amount of steatosis in different lobes of the liver, and to evaluate intra- and inter-Observer variability in lipid point counting. Computer-assisted point counting of lipid droplets was undertaken following Oil-Red-O staining in 21 dogs with congenital portosystemic shunts and 9 control dogs. Dogs with congenital portosystemic shunts had significantly more small lipid droplets ( 9 μ) and lipogranulomas per tissue point (p = 0.023 and 0.01, respectively). In conclusion, computer-assisted counting of lipid droplets following Oil Red O staining of liver biopsy samples allows objective measurement and detection of significant differences between dogs with CPS and normal dogs. This method will allow future evaluation of the relationship between different presentations of CPS (anatomy, age, breed) and lipidosis, as well as the impact of hepatic lipidosis on outcomes following surgical shunt attenuation. PMID:23528942

  8. Alterations in sulfur and nitrogen metabolism in rats with portacaval shunts

    International Nuclear Information System (INIS)

    Benjamin, L.E.

    1985-01-01

    The effect of portacaval shunt (PCS) on methionine and cysteine metabolism was investigated. PCS rats excreted more urinary [ 35 S]sulfate and less [ 35 S]taurine than controls after injection of [ 35 S]methionine of [ 35 S]cysteine. Total urinary taurine excretion was unchanged. Under basal conditions PCS rats excreted more taurine than controls. Relative rates of transsulfuration in PCS and control rats were studied, and no difference in flux of 35 S from methionine to cysteine was found. Total hepatic activities of three transsulfuration pathway enzymes were also unchanged after PCS. In contrast, hepatic activities of three cysteine-oxidizing enzymes were depressed after PCS, suggesting that changes in hepatic metabolism after PCS are selective. PCS rats fed a high (60%) casein diet ate less and took longer to recover their preoperative body weight than controls. All PCS rats had higher plasma ammonia and urinary orotic acid levels than controls. Increasing dietary protein elevated plasma ammonia and urinary orotic acid to a greater extent in PCS rats. After injection of [ 35 S]methionine or [ 35 S]cysteine, urinary 35 S and [ 35 S]sulfate excretion increased and [ 35 S]taurine an total taurine excretion decreased in all rats fed 60% casein, but the effect was greater in PCS rats. Changes in cysteine sulfinate decarboxylase activity in rats fed a high protein diet was examined. Activity decreased 95% in rats fed diets containing between 18 and 75% casein. The effect was observed after feeding a 60% casein diet for 2 days and was reversed when rats were refed an 18% casein diet

  9. Abnormal Gas Diffusing Capacity and Portosystemic Shunt in Patients With Chronic Liver Disease

    OpenAIRE

    Park, Moon-Seung; Lee, Min-Ho; Park, Yoo-Sin; Kim, Shin-Hee; Kwak, Min-Jung; Kang, Ju-Seop

    2012-01-01

    Background Pulmonary dysfunctions including the hepatopulmonary syndrome and portosystemic shunt are important complications of hepatic cirrhosis. To investigate the severity and nature of abnormal gas diffusing capacity and its correlation to portosystemic shunt in patients with chronic liver disease. Methods Forty-four patients with chronic liver disease (15 chronic active hepatitis (CAH), 16 Child-Pugh class A, and 13 Child-Pugh class B) without other diseases history were enrolled in the ...

  10. Optimizing the Shunting Schedule of Electric Multiple Units Depot Using an Enhanced Particle Swarm Optimization Algorithm

    Science.gov (United States)

    Jin, Junchen

    2016-01-01

    The shunting schedule of electric multiple units depot (SSED) is one of the essential plans for high-speed train maintenance activities. This paper presents a 0-1 programming model to address the problem of determining an optimal SSED through automatic computing. The objective of the model is to minimize the number of shunting movements and the constraints include track occupation conflicts, shunting routes conflicts, time durations of maintenance processes, and shunting running time. An enhanced particle swarm optimization (EPSO) algorithm is proposed to solve the optimization problem. Finally, an empirical study from Shanghai South EMU Depot is carried out to illustrate the model and EPSO algorithm. The optimization results indicate that the proposed method is valid for the SSED problem and that the EPSO algorithm outperforms the traditional PSO algorithm on the aspect of optimality. PMID:27436998

  11. Optimizing the Shunting Schedule of Electric Multiple Units Depot Using an Enhanced Particle Swarm Optimization Algorithm

    Directory of Open Access Journals (Sweden)

    Jiaxi Wang

    2016-01-01

    Full Text Available The shunting schedule of electric multiple units depot (SSED is one of the essential plans for high-speed train maintenance activities. This paper presents a 0-1 programming model to address the problem of determining an optimal SSED through automatic computing. The objective of the model is to minimize the number of shunting movements and the constraints include track occupation conflicts, shunting routes conflicts, time durations of maintenance processes, and shunting running time. An enhanced particle swarm optimization (EPSO algorithm is proposed to solve the optimization problem. Finally, an empirical study from Shanghai South EMU Depot is carried out to illustrate the model and EPSO algorithm. The optimization results indicate that the proposed method is valid for the SSED problem and that the EPSO algorithm outperforms the traditional PSO algorithm on the aspect of optimality.

  12. Vascularização temporária de membros isquêmicos por meio de shunt arteriomedular: trabalho experimental Temporary vascularization on ischemic limbs through arterial-medullar shunt: an experimental work

    Directory of Open Access Journals (Sweden)

    Ronaldo André Poerschke

    2012-03-01

    Full Text Available CONTEXTO: Os autores idealizaram um shunt temporário entre a artéria femoral e o canal medular de ossos longos para manter a viabilidade dos membros agudamente isquêmicos, enquanto não é possível estabelecer um tratamento definitivo. OBJETIVO: Avaliar a perviedade de shunts temporários arteriomedulares e a perfusão dos membros, durante duas horas em cães de experimentação, que tiveram a artéria femoral ligada. MÉTODOS: Alocaram-se aleatoriamente dois grupos, com três cães no Grupo Controle e seis no Grupo Intervenção. Os controles tiveram a artéria femoral comum direita ligada. O Grupo Intervenção, além da ligadura da artéria, recebeu um shunt. Após duas horas, realizou-se a medida de pH dos membros isquêmicos; avaliação do fluxo arterial por meio de um sonar Doppler; avaliação da coloração do sangramento na extremidade distal do membro e foram retirados em bloco torácico os pulmões para análise anatomopatológica. RESULTADOS: A média do pH do sangue capilar das extremidades do membros no Grupo Controle foi de 6,97 (±0,39; no Grupo Intervenção o pH foi de 7,25 (±0,46, com pBACKGROUND: The authors idealized a temporary shunt between the femoral artery and the medullar canal on long bones to keep the viability of acutely ischemic limbs, while waiting for a definitive treatment. OBJECTIVE: To assess the flow on temporary shunts between the femoral artery and the marrow canal of the tibia during two hours in experimental dogs, which had the femoral artery interrupted. METHODS: Two groups with three dogs on the Control Group and six on the Intervention Group were allocated at random. The controls had the right femoral common artery interrupted. The Intervention Group received a shunt between the iliac external artery and the medullar canal of the right tibia in addition. After two hours, the measure of the pH, blood coloration, blood flow in sonar Doppler on the ischemic limbs were performed. The lungs were

  13. k-Shortest routing of trains on shunting yards

    NARCIS (Netherlands)

    Riezebos, Jan; van Wezel, Wout

    2009-01-01

    We consider the problem of designing algorithmic support for k-best routing decisions in train shunting scheduling. A study at the Netherlands Railways revealed that planners like to interact with the solution process of finding suitable routes. Two types of interaction were required: the

  14. Initial shunt type at the Norwood operation impacts myocardial function in hypoplastic left heart syndrome.

    Science.gov (United States)

    Ruotsalainen, Hanna K; Pihkala, Jaana; Salminen, Jukka; Hornberger, Lisa K; Sairanen, Heikki; Ojala, Tiina

    2017-08-01

    We investigated the impact of initial shunt type, a Blalock-Taussig (BT) shunt versus a right ventricle to pulmonary artery conduit (RV-PA) on myocardial function at different stages of surgical palliation in patients with hypoplastic left heart syndrome (HLHS). A population-based cohort of 63 Finnish children with HLHS (BT n  = 23, RV-PA n  = 40) born between 2003 and 2010 were studied retrospectively by echocardiography prior to Stages 1, 2 and 3 palliation and 0.5-3 years after Stage 3. For comparison of systolic myocardial function, we evaluated the RV fractional area change (FAC), strain, strain rate and mechanical synchrony from the apical 4-chamber view by velocity vector imaging. There were no intergroup differences in demographics during the study period. At baseline, no intergroup differences were detected in RV systolic myocardial function. Before Stage 2, RV FAC was higher ( P  = 0.03) in the RV-PA conduit group. At Stage 3, an increase in all systolic myocardial functional parameters was observed in the BT shunt group. After Stage 3, the BT shunt group had better RV systolic function. In multiple regression analysis, the shunt type and the stage of palliation had an impact on myocardial function. Although patients with HLHS initially palliated with a BT shunt demonstrate lower RV FAC after Stage I, RV FAC improves after Stage 2 with better systolic performance after Stage 3 compared with those initially palliated with an RV-PA conduit. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  15. Finite Element and Experimental Study of Shunting in Resistance Spot Welding

    DEFF Research Database (Denmark)

    Seyyedian Choobi, M.; Nielsen, C. V.; Bay, N.

    2015-01-01

    This research is focused on one of the problems frequently encountered in spot welding in industry. In many applications several spot welds are made close to each other. The spots made after the first spot may become smaller in size due to shunt effect. A numerical and experimental study has been...... conducted to investigate the effect of shunting on nugget size in spot welding of HSLA steel sheets. Different cases with different spacing between weld spots have been examined. The nugget sizes have been measured by metallographic examination and have been compared with 3D finite element simulations...

  16. Ventriculoperitoneal shunt infection caused by Bifidobacterium breve.

    Science.gov (United States)

    Suwantarat, Nuntra; Romagnoli, Mark; Wakefield, Teresa; Carroll, Karen C

    2014-08-01

    Bifidobacterium breve is a rare cause of human infections. Previously, bacteremia and meningitis caused by this organism linked to probiotic use have been reported in a neonate. We report the first case of a ventriculoperitoneal shunt infection caused by B. breve in an adult without a history of probiotic use. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Study of Anterior Chamber Aqueous Tube Shunt by Fourier-Domain Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Chunhui Jiang

    2012-01-01

    Full Text Available Purpose. This cross-sectional, observational study used Fourier-domain optical coherence tomography (OCT to examine the position, patency, and the interior entrance site of anterior chamber (AC aqueous tube shunts. Methods. The OCT, slitlamp biomicroscopy, and gonioscopy findings of 23 eyes of 18 patients with AC shunts were collected and compared. Results. OCT images demonstrated the shunt position and patency in all 23 eyes, and the details of the AC entrance in 16 eyes. The position of the tube varied, with the majority (14/23 on the surface of the iris. The exact position of the AC entrance relative to Schwalbe’s line (SL could be determined in 9 eyes (posterior to SL in 7 eyes, anterior in 2 eyes. At the AC entrance, growth of fibrous scar tissue was present between the tube and the corneal endothelium in all 16 eyes in which the entrance could be clearly visualized. It’s a new finding that could not be visualized by slitlamp examination or lower resolution OCT. Conclusion. Compared to slitlamp examination, Fourier-domain OCT of AC tube shunts provided more detailed anatomic information regarding the insertion level relative to SL, scar tissue between the tube and the corneal endothelium, and patency of the tube opening.

  18. Phase Locking and Chaos in a Josephson Junction Array Shunted by a Common Resistance

    International Nuclear Information System (INIS)

    Tie-Ge, Zhou; Jing, Mao; Ting-Shu, Liu; Yue, Lai; Shao-Lin, Yan

    2009-01-01

    The dynamics of a Josephson junction array shunted by a common resistance are investigated by using numerical methods. Coexistence of phase locking and chaos is observed in the system when the resistively and capacitively shunted junction model is adopted. The corresponding parameter ranges for phase locking and chaos are presented. When there are three resistively shunted junctions in the array, chaos is found for the first time and the parameter range for chaos is also presented. According to the theory of Chernikov and Schmidt, when there are four or more junctions in the array, the system exhibits chaotic behavior. Our results indicate that the theory of Chernikov and Schmidt is not exactly appropriate. (condensed matter: electronicstructure, electrical, magnetic, and opticalproperties)

  19. Quantitation of the intrahepatic shunt index by injection of /sup 99m/Tc-macroaggregated albumin into the spleen

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Masaaki; Ohnishi, Kunihiko; Katsurai, Hiroshi; Tanaka, Hideo; Chin, Nobuyoshi; Iida, Shinji; Nomura, Fumio; Okuda, Kunio

    1987-11-01

    The accuracy of the intrahepatic shunt index measured by injection of /sup 99m/Tc-macroaggregated albumin into the spleen was assessed in comparison with the intrahepatic shunt index measured by injection of /sup 99m/Tc-macroaggregated albumin into the portal trunk in 28 patients with portal hypertension. /sup 99m/Tc-macroaggregated albumin was injected through the catheter into the portal trunk and the intrahepatic shunt index was calculated by counting over predetermined areas of the liver and lungs. Injection of /sup 99m/Tc-macroaggregated albumin into the spleen was performed between one or two weeks before portal vein catheterization, and the calculation of the intrahepatic shunt index was performed with a scinticamera and ROI-radiograms obtained by data-processing. There was a significant correlation between the intrahepatic shunt index calculated by injection of /sup 99m/Tc-macroaggregated albumin into the spleen and that by injection of /sup 99m/Tc-macroaggregated albumin into the portal trunk (r = 0.90, p < 0.001)

  20. Performance analysis of a simple shunt and series compensated six-phase self-excited induction generator for stand-alone renewable energy generation

    International Nuclear Information System (INIS)

    Singh, G.K.; Kumar, A. Senthil; Saini, R.P.

    2011-01-01

    This paper describes a new generalized and efficient model for performance analysis of a six-phase self-excited induction generator (SPSEIG) with three capacitor excitation topologies; simple shunt, short shunt and long shunt. Mathematical model of SPSEIG is formulated using nodal admittance method based on graph theory. Attention is focused on the influence of the different capacitor connections on the generator overload and output power capabilities. The generator voltage with simple shunt excitation connection collapses when it is overloaded while with either the short shunt or long shunt excitation connection; generator is able to sustain the load at a lower operating voltage and larger load current. The matrix equation developed by nodal admittance method is solved by Genetic Algorithm (GA) technique to predetermine the steady-state performance of SPSEIG. The experimental and theoretical results are found to be in good agreement.

  1. Prevalence of patent foramen ovale with right-to-left shunting in dogs with pulmonic stenosis.

    Science.gov (United States)

    Fujii, Y; Nishimoto, Y; Sunahara, H; Takano, H; Aoki, T

    2012-01-01

    Right-to-left (R-L) shunt caused by patent foramen ovale (PFO) concurrent with pulmonic stenosis (PS) is considered common, although there is a lack of published evidence. To investigate the prevalence of R-L shunt caused by a PFO in dogs with PS. Thirty-one client-owned dogs with PS, without obvious extracardiac disease detected on the clinical examinations. Case control study: R-L shunt probably caused by PFO was diagnosed when IV injected microbubbles appeared at the left atrial level with an intact atrial septum on echocardiography (bubble-positive dogs). The severity of PS concurrent tricuspid regurgitation (TR), relative thickness of the right ventricle, and relative right atrial area were compared between bubble-positive and bubble-negative dogs. The prevalence of R-L shunts caused by PFO was 39% (12 of 31 cases). The instantaneous pressure gradient (PG) across the pulmonic valve and relative thickness of the right ventricle were significantly increased in bubble-positive compared with those in bubble-negative dogs. None of the dogs with mild or moderate PS (pressure gradient dogs was significantly higher than that in bubble-negative dogs. DISCUSSION AND CLINICAL RELEVANCE: Patent foramen ovale PFO with R-L shunt was more common in dogs with very severe PS and absent in dogs with mild PS. Copyright © 2011 by the American College of Veterinary Internal Medicine.

  2. [The use of labelled albumin microspheres in the study of arteriovenous shunting in varicosities of the lower limbs (author's transl)].

    Science.gov (United States)

    Serise, J M; Le Héron, D; Le Héron, G; Bonnet, A; Busquet, J; Basse-Cathalinat, B; Tingaud, R

    1982-01-01

    The greater proportion of oxygen in the blood circulating in veins of the lower limbs bought to attention the possibility of pre-capillary arteriovenous shunting. The intra-arteriel injection of Technetium labelled serum albumin microspheres enables one to quantify arteriovenous shunts greater than 25 microns. The authors made a comparative study of arterio-venous shunting by blood gases analysis and isotopic techniques in twenty patients. The results seem to deny the existence of arteriovenous shunts in the genesis of essential varicose veins in the lower limb.

  3. N-butyl cyanoacrylate embolization with blood flow control of an arterioportal shunt that developed after radiofrequency ablation of hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Sonomura, Tetsuo; Kawai, Nobuyuki; Kishi, Kazushi [Wakayama Medical University, Wakayama (Japan); and others

    2014-04-15

    We present a case of a patient with rapid deterioration of esophageal varices caused by portal hypertension accompanied by a large arterioportal shunt that developed after radiofrequency ablation of hepatocellular carcinoma. We used n-butyl cyanoacrylate (NBCA) as an embolic material to achieve pinpoint embolization of the shunt, because the microcatheter tip was 2 cm away from the shunt site. Under hepatic arterial flow control using a balloon catheter, the arterioportal shunt was successfully embolized with NBCA, which caused an improvement in the esophageal varices.

  4. [The 2,3-diphosphoglycerate shunt and stabilization of the ATP level in mammalian erythrocytes].

    Science.gov (United States)

    Ataullakhanov, A I; Ataullakhanov, F I; Vitvitskiĭ, V M; Zhabotinskiĭ, A M; Pichugin, A V

    1985-06-01

    The mechanisms of regulation of energy metabolism in erythrocytes of various mammalian species were investigated. In native erythrocytes of man, sheep, cow, dog and mouse the dependencies of the rates of glucose uptake on ATP concentration (i.e., regulatory parameters of glycolysis) were measured. These parameters plotted in normalized coordinates are not species-specific (invariant). The dependence of the rate of ATP-consuming processes on ATP concentration has been studied for the first time in intact mammalian erythrocytes. This dependence was found to be linear only in the species, in whose erythrocytes the activity of 2,3-diphosphoglycerate shunt is practically zero. In all species under study, the stabilization of ATP level is provided for mainly by the hexokinase-phosphofructokinase system. A comparison of regulatory mechanisms of energy metabolism in mammalian (sheep, cow) erythrocytes, in which the 2,3-diphosphoglycerate shunt is absent, with human and animal erythrocytes, in which this pathway is active, points to the important role of the 2,3-diphosphoglycerate shunt in regulation of energy conversion in erythrocytes. This shunt operates as an additional stabilizer protecting the cell from extremal influences.

  5. Modeling the effect of shunt current on the charge transfer efficiency of an all-vanadium redox flow battery

    Science.gov (United States)

    Chen, Yong-Song; Ho, Sze-Yuan; Chou, Han-Wen; Wei, Hwa-Jou

    2018-06-01

    In an all-vanadium redox flow battery (VRFB), a shunt current is inevitable owing to the electrically conductive electrolyte that fills the flow channels and manifolds connecting cells. The shunt current decreases the performance of a VRFB stack as well as the energy conversion efficiency of a VRFB system. To understand the shunt-current loss in a VRFB stack with various designs and operating conditions, a mathematical model is developed to investigate the effects of the shunt current on battery performance. The model is calibrated with experimental data under the same operating conditions. The effects of the battery design, including the number of cells, state of charge (SOC), operating current, and equivalent resistance of the electrolytes in the flow channels and manifolds, on the shunt current are analyzed and discussed. The charge-transfer efficiency is calculated to investigate the effects of the battery design parameters on the shunt current. When the cell number is increased from 5 to 40, the charge transfer efficiency is decreased from 0.99 to a range between 0.76 and 0.88, depending on operating current density. The charge transfer efficiency can be maintained at higher than 0.9 by limiting the cell number to less than 20.

  6. The transjugular intrahepatic portosystemic shunt (TIPS)

    International Nuclear Information System (INIS)

    Owen, A.R.; Stanley, A.J.; Vijayananthan, A.; Moss, J.G.

    2009-01-01

    The creation of an intrahepatic portosystemic shunt via a transjugular approach (TIPS) is an interventional radiological procedure used to treat the complications of portal hypertension. TIPS insertion is principally indicated to prevent or arrest variceal bleeding when medical or endoscopic treatments fail, and in the management refractory ascites. This review discusses the development and execution of the technique, with focus on its clinical efficacy. Patient selection, imaging surveillance, revision techniques, and complications are also discussed.

  7. The transjugular intrahepatic portosystemic shunt (TIPS)

    Energy Technology Data Exchange (ETDEWEB)

    Owen, A.R. [Department of Radiology, Austin Health, Heidelberg, Melbourne (Australia)], E-mail: andrewowen@doctors.org.uk; Stanley, A.J. [Department of Gastroenterology, Glasgow Royal Infirmary, Glasgow (United Kingdom); Vijayananthan, A. [Department of Biomedical Imaging, University of Malaya, Kuala Lumpur (Malaysia); Moss, J.G. [Department of Radiology, Gartnavel General Hospital, Glasgow (United Kingdom)

    2009-07-15

    The creation of an intrahepatic portosystemic shunt via a transjugular approach (TIPS) is an interventional radiological procedure used to treat the complications of portal hypertension. TIPS insertion is principally indicated to prevent or arrest variceal bleeding when medical or endoscopic treatments fail, and in the management refractory ascites. This review discusses the development and execution of the technique, with focus on its clinical efficacy. Patient selection, imaging surveillance, revision techniques, and complications are also discussed.

  8. Measurement ot the switching over-voltages at the disconnection of the high voltage shunt reactors in the Romanian power system

    Energy Technology Data Exchange (ETDEWEB)

    Stroica, Paul Constantin; Merfu, Ion; Stroica, Mihail; Merfu, Marius; Cojocaru, Florian; Stefan, Dinu; Cojocaru, Mihai

    2010-09-15

    The paper presents the measurements of the switching over-voltages made in the Romanian Power System, at the 400/220/110 kV Urechesti substation at the disconnection of a 400 kV, 100 MVAr shunt reactor type DFAL, Siemens, Germany, in 3 consecutive versions. The first one is for shunt reactor controlled by live-tank oil circuit breaker, the second one is for shunt reactor controlled by SF6 circuit breaker, and the third one is for shunt reactor controlled by SF6 circuit breaker and synchronize device.

  9. Metallurgical Effects of Shunting Current on Resistance Spot-Welded Joints of AA2219 Sheets

    Science.gov (United States)

    Jafari Vardanjani, M.; Araee, A.; Senkara, J.; Jakubowski, J.; Godek, J.

    2016-08-01

    Shunting effect is the loss of electrical current via the secondary circuit provided due to the existence of previous nugget in a series of welding spots. This phenomenon influences on metallurgical aspects of resistance spot-welded (RSW) joints in terms of quality and performance. In this paper RSW joints of AA2219 sheets with 1 mm thickness are investigated metallurgically for shunted and single spots. An electro-thermal finite element analysis is performed on the RSW process of shunted spot and temperature distribution and variation are obtained. These predictions are then compared with experimental micrographs. Three values of 5 mm, 20 mm, and infinite (i.e., single spot) are assumed for welding distance. Numerical and experimental results are matching each other in terms of nugget and HAZ geometry as increasing distance raised nugget size and symmetry of HAZ. In addition, important effect of shunting current on nugget thickness, microstructure, and Copper segregation on HAZ grain boundaries were discovered. A quantitative analysis is also performed about the influence of welding distance on important properties including ratio of nugget thickness and diameter ( r t), ratio of HAZ area on shunted and free side of nugget ( r HA), and ratio of equivalent segregated and total amount of Copper, measured in sample ( r Cu) on HAZ. Increasing distance from 5 mm to infinite, indicated a gain of 111.04, -45.55, and -75.15% in r t, r HA, and r Cu, respectively, while obtained ratios for 20 mm welding distance was suitable compared to single spot.

  10. Association of ischemic stroke, hormone therapy, and right to left shunt in postmenopausal women.

    Science.gov (United States)

    Greep, Nancy C; Liebeskind, David S; Gevorgyan, Rubine; Truong, Tam; Cua, Bennett; Tseng, Chi-Hong; Dodick, David W; Demaerschalk, Bart M; Thaler, David E; Tobis, Jonathan M

    2014-09-01

    Postmenopausal hormone therapy (HT) increases the risk of venous thrombosis and ischemic stroke. We postulated that HT might increase the risk of ischemic stroke by promoting venous clots that travel to the brain through a right to left shunt (RLS). A total of 2,389 records were studied. After eliminating the premenopausal patients, and those with TIAs and non-ischemic strokes, the medical records of 1846 postmenopausal women hospitalized at four institutions for ischemic stroke were reviewed to identify those who had undergone an adequate study to assess for RLS. The proportion of women with a shunt in users and non-users of HT was compared in stroke patients and in a reference population consisting of postmenopausal women undergoing elective cardiac catheterization. There were 363 (20%) records that had complete data and were included in the analysis. A shunt was more prevalent in patients with a cryptogenic stroke than in patients with a stroke of known cause (55/88 (63%) vs. 53/275 (19%), P women 31/136 (23%), and the proportion of women with a shunt was similar in non-users and current users of HT (14% vs. 20%, P = 0.40). However, among patients with a cryptogenic stroke, the prevalence of a shunt was 1.5 times higher in current users than non-users of HT (82% vs. 56%, P = 0.04). Approximately 23% of older women have a RLS. HT in these women may increase the risk of ischemic stroke by promoting paradoxical embolism. © 2014 Wiley Periodicals, Inc.

  11. Retinal complications after aqueous shunt surgical procedures for glaucoma.

    Science.gov (United States)

    Law, S K; Kalenak, J W; Connor, T B; Pulido, J S; Han, D P; Mieler, W F

    1996-12-01

    To assess retinal complications and to identify risk factors for retinal complications following aqueous shunt procedures. Records of 38 consecutive aqueous shunt procedures that were performed on 36 patients at the Eye Institute of the Medical College of Wisconsin, Milwaukee, from June 1993 to March 1995 (minimum follow-up, 6 months) were reviewed. The mean +/- SD follow-up was 11.4 +/- 5.2 months (median, 10.5 months). Twelve patients (32%) had the following retinal complications: 4 serous choroidal effusions (10%) that required drainage, 3 suprachoroidal hemorrhages (8%), 2 vitreous hemorrhages (5%), 1 rhegmatogenous retinal detachment (3%), 1 endophthalmitis (3%), and 1 scleral buckling extrusion (3%). Surgical procedures for retinal complications were required in 8 (67%) of these 12 patients. Visual acuity decreased 2 lines or more in 9 (75%) of these 12 patients. The median onset of a postoperative retinal complication was 12.5 days, with 10 patients (83%) experiencing complications within 35 days. Serous choroidal effusions developed in 10 other patients (26%), and these effusions resolved spontaneously. Visual acuity decreased 2 lines or more in 2 (20%) of these additional 10 patients. Patients who experienced serious retinal complications were significantly older, had a higher rate of hypertension, and postoperative ocular hypotony. Serious retinal complications were distributed evenly among patients with Krupin valves with discs and Molteno and Baerveldt devices. Experience with the Ahmed glaucoma valve implant was limited. Aqueous shunt procedures may be associated with significant retinal complications and subsequent visual loss.

  12. Migration of a ventriculo-peritoneal shunt catheter into a back incision of a patient with previous spinal fusion.

    Science.gov (United States)

    Suryadevara, Raviteja; Lieber, Bryan A; Garcia, Erick; Sood, Sandeep; Haridas, Abilash; Ham, Steven

    2018-04-01

    This case examines a unique, longitudinal presentation of an abandoned, migrating VP shunt which presents as multiple complications, including a weeping abscess in the patients back. We believe that the latter complication was potentially caused by the wound from the patient's previous history of spinal fusion surgery. The patient presents with an associated type 2 Chiari malformation, hydrocephalus, and a previous history of posterior spinal fusion (T4-L5 anterior fusion and T2-L5 posterior fusion) at age 11. The patient had undergone shunt revisions in early adolescence as well. At 22, the patient is admitted into emergency care due to recurrent infections caused by a migrating VP shunt. Due to complications in corrective surgery at the time, the shunt was forced to be abandoned. This resulted in the most recent presentation of a weeping abscess at the patient's spinal fusion surgery wound; the culprit was the abandoned, migrating VP shunt.. An initial course of broad-spectrum antibiotics was started. However, the abscess continued to recur. Eventually, the catheter was surgically removed, a tailored antibiotic regiment was started, and a 6-month patient follow-up was performed. The patient is no longer symptomatic and off of antibiotics. In abandoned VP shunts, migration into a non-sterile cavity dictates prompt removal, especially after symptoms of infection present. Additionally, careful monitoring for signs of peritonitis or other symptoms for a dedicated period of time is necessary. To the authors' best knowledge, this is the first case of an occult shunt migration through the patient's back that presented with a weeping abscess.

  13. Use of 99mTCO4(-) trans-splenic portal scintigraphy for diagnosis of portosystemic shunts in 28 dogs.

    Science.gov (United States)

    Morandi, Federica; Cole, Robert C; Tobias, Karen M; Berry, Clifford R; Avenell, James; Daniel, Gregory B

    2005-01-01

    Ultrasound-guided percutaneous trans-splenic portal scintigraphy (TSPS) using 99mTcO4(-) has been used to image the portal venous system in normal dogs. Compared with per-rectal portal scintigraphy, it provides higher count density, consistent nuclear venograms of the splenic and portal vein, and significantly decreased radiation exposures. This paper describes the use of TSPS for the diagnosis of portosystemic shunts in 28 dogs. TSPS was performed injecting 70 +/- 28 MBq of 99mTcO4(-) (mean +/- SD) into the splenic parenchyma with ultrasound guidance. A dynamic acquisition at a frame rate of four frames/s for 5 min was initiated after placement of the needle and approximately 2s prior to injection. All dogs had diagnoses confirmed via exploratory laparotomy or ultrasonographic identification of the shunting vessel(s). Three studies (10.7%) were nondiagnostic because of intraperitoneal rather than intrasplenic injection of the radionuclide. Three pathways were recognized on the scintigraphic images: (1) portoazygos shunts--the 99mTcO4(-) bolus traveled dorsally, running parallel to the spine and entering the heart craniodorsally; (2) single portocaval or splenocaval shunts--the 99mTcO4(-) bolus ran from the area of the portal vein/splenic vein junction in a linear fashion toward the caudal vena cava entering the heart caudally; (3) internal thoracic shunt-the 99mTcO4 bolus traveled ventrally along the thorax and abdomen entering the cranial aspect of the heart. Single and multiple shunts were easily distinguished. There were no distinguishing features between single intra and extrahepatic portocaval shunts.

  14. Diagnostic imagings and embolotherapy for the superior mesenteric vein-inferior vena cava shunt

    International Nuclear Information System (INIS)

    Morita, Yutaka; Yamada, Masataka; Miyata, Mutsuhiko; Kubo, Kohzo.

    1994-01-01

    Diagnostic imaging and embolization therapy for the uncommon portal and mesenteric vein-inferior vena cave shunt (PV·SMV-IVC shunt) are reported. As the frequency of clinical symptoms such as hematemesis, melena and confusion caused by gastrointestinal varices, or hepatoencephalopathy was about 40%, it was important for this disease entity to be diagnosed with noninvasive diagnostic images. The careful examination of the area around the right renal vein was able to overcome the low diagnostic rate of 20-40% obtained with US and CT images. In cases of simple PV·SMV-IVC shut without gastrointestinal varices, embolization therapy using steel coils and done by the intravenous approach is easy and noninvasive. On the other hand, in cases of complex PV-SMV-IVC shunt with gastrointestinal varices, dual balloon occluded embolization therapy using a liquid sclerosing agent and done by the intravenous and portal approaches is preferable. (author)

  15. Vaginal extrusion of a ventriculo-peritoneal shunt catheter in an adult

    Directory of Open Access Journals (Sweden)

    Christopher M Bonfield

    2015-01-01

    Full Text Available Ventriculo-peritoneal shunts (VPS are commonly used in the treatment of various neurosurgical conditions, including hydrocephalus and pseudotumor cerebri. We report only the second case of vaginal extrusion of a VPS catheter in an adult, and the first case with a modern VPS silastic peritoneal catheter. A 45-year-old female with a history of VPS for pseudotumor cerebri, Behcet′s syndrome, and hysterectomy presented to our institution with the chief complaint of tubing protruding from her vagina after urination. On gynecologic examination, the patient was found to have approximately 15 cm of VPS catheter protruding from her vaginal apex. A computed tomography scan of the abdomen and shunt X-ray series demonstrated no breaks in the tubing, but also confirmed the finding of the VPS catheter extruding through the vaginal cuff into the vagina. The patient had the VPS removed and an external ventricular drain was placed for temporary cerebrospinal fluid diversion. Ventricular catheter cultures were positive for diphtheroids. After an appropriate course of antibiotics, a contralateral ventriculo-pleural shunt was placed one week later. Although vary rare, vaginal extrusion can occur in adults, even with modern VPS catheters.

  16. Usefulness of a pleuroperitoneal shunt for treatment of refractory pleural effusion in a patient receiving maintenance hemodialysis.

    Science.gov (United States)

    Habuka, Masato; Ito, Toru; Yoshizawa, Yuta; Matsuo, Koji; Murakami, Shuichi; Kondo, Daisuke; Kanazawa, Hiroshi; Narita, Ichiei

    2018-03-23

    Refractory pleural effusion can be a life-threatening complication in patients receiving maintenance hemodialysis. We report successful treatment of refractory pleural effusion using a Denver® pleuroperitoneal shunt in one such patient. A 54-year-old Japanese man, who had previously undergone left nephrectomy, was admitted urgently to our department because of a high C-reactive protein (CRP) level, right pleural effusion, and right renal abscess. Because antibiotics proved ineffective and his general state was deteriorating, he underwent emergency insertion of a thoracic drainage tube and nephrectomy, and hemodialysis was started. Although his general state improved slowly thereafter, the pleural effusion, which was unilateral and transudative, remained refractory and therefore he needed to be on oxygenation. To control the massive pleural effusion, a pleuroperitoneal shunt was inserted. Thereafter, his respiratory condition became stable without oxygenation and he was discharged. His general condition has since been well. Although pleural effusion is a common complication of maintenance hemodialysis, few reports have documented the use of pleuroperitoneal shunt to control refractory pleural effusion. Pleuroperitoneal shunt has been advocated as an effective and low-morbidity treatment for refractory pleural effusion, and its use for some patients with recurrent pleural effusion has also been reported, without any severe complications. In the present case, pleuroperitoneal shunt improved the patient's quality of life sufficiently to allow him to be discharged home without oxygenation. Pleuroperitoneal shunt should be considered a useful treatment option for hemodialysis patients with refractory pleural effusion.

  17. Train shunting at a workshop area

    DEFF Research Database (Denmark)

    Jacobsen, Per Munk; Pisinger, David

    2011-01-01

    We consider the problem of planning the shunting of train units at a railway workshop area. Before and after the maintenance check, a train unit is parked at a depository track. The problem is to schedule the trains to workshops and depot tracks in order to complete the repairs as soon as possibl....... It turns out, that both GLS and SA find within a few minutes solutions that are a few percent from the best MIP solution found....

  18. Measurement of left-to-right shunts by gated radionuclide angiography: concise communication

    International Nuclear Information System (INIS)

    Rigo, P.; Chevigne, M.

    1982-01-01

    Gated cardiac blood-pool scans allow comparison of left- and right-ventricular stroke volume. We have applied these measurements to the quantification of left-to-right shunts (QP/QS) in nine patients with atrial septal defects, one patients with partial anomalous pulmonary venous return, four patients with ventricular septal defects, and two patients with patent ductus arteriosus. None of these patients had combined lesions. QP/QS was measured as the right-ventricular (RV) stroke counts divided by the left-ventricular (LV) stroke counts and as the LV stroke counts divided by the RV stroke counts in patients with RV and LV diastolic volume overload respectively. All patients had also QP/QS measurements by oximetry and first-pass radionuclide angiography. The stroke-count measurements indicated the overloaded ventricle in all patients. QP/QS determined by equilibrium gated studies correlated well with those obtained by oximetry (r . 0.79). Reproducibility of the equilibrium measurements was good. We conclude that gated cardiac blood-pool scans can measure left-to-right shunts and can distinguish between shunts with RV and LV volume overload

  19. Quality measurement in the shunt treatment of hydrocephalus: analysis and risk adjustment of the Revision Quotient.

    Science.gov (United States)

    Piatt, Joseph H; Freibott, Christina E

    2014-07-01

    OBJECT.: The Revision Quotient (RQ) has been defined as the ratio of the number of CSF shunt revisions to the number of new shunt insertions for a particular neurosurgical practice in a unit of time. The RQ has been proposed as a quality measure in the treatment of childhood hydrocephalus. The authors examined the construct validity of the RQ and explored the feasibility of risk stratification under this metric. The Kids' Inpatient Database for 1997, 2000, 2003, 2006, and 2009 was queried for admissions with diagnostic codes for hydrocephalus and procedural codes for CSF shunt insertion or revision. Revision quotients were calculated for hospitals that performed 12 or more shunt insertions annually. The univariate associations of hospital RQs with a variety of institutional descriptors were analyzed, and a generalized linear model of the RQ was constructed. There were 12,244 admissions (34%) during which new shunts were inserted, and there were 23,349 admissions (66%) for shunt revision. Three hundred thirty-four annual RQs were calculated for 152 different hospitals. Analysis of variance in hospital RQs over the 5 years of study data supports the construct validity of the metric. The following factors were incorporated into a generalized linear model that accounted for 41% of the variance of the measured RQs: degree of pediatric specialization, proportion of initial case mix in the infant age group, and proportion with neoplastic hydrocephalus. The RQ has construct validity. Risk adjustment is feasible, but the risk factors that were identified relate predominantly to patterns of patient flow through the health care system. Possible advantages of an alternative metric, the Surgical Activity Ratio, are discussed.

  20. Modified temporary end-to-side portocaval shunt in liver and small bowel transplantation.

    Science.gov (United States)

    Molmenti, E P; Marsh, J W; Molmenti, H; Reyes, J; Fung, J J

    2001-10-01

    Piggyback orthotopic liver transplantation (LTx) has permitted the elimination of extra-corporeal venovenous bypass. In some instances, an internal temporary portocaval shunt has to be constructed in order to prevent hemodynamic instability. We describe a technique in which a donor iliac vein graft is used to bridge the distance between the portal vein and vena cava in cases where a direct shunt cannot be constructed. This technique can be applied to liver Tx as well as to liver and small bowel Tx.

  1. Ectopic cystoperitoneal shunt demonstrated by valvulography. A case report

    Energy Technology Data Exchange (ETDEWEB)

    Jofre, M J; Sierralta, M P [Military Hospital Nuclear Medicine Department, Santiago (Chile)

    2002-09-01

    The most important and frequent complications in the management of hydrocephalus treated with a derivation system are the infection and obstruction of the ventriculoperitoneal or ventriculoatrial shunt. However, another less frequent problem is the migration of the distal catheter. The case report presented is a 20 year-old girl who started, when she was 12, with severe headaches and epileptogenic seizures. She was diagnosed with a left parietotemporal aracnoidal cyst and a cystoperitoneal shunt was installed. However, she continued to have headaches. In September 1999, the derivation system was controlled with a radionuclide valvulography, which demonstrated shunt patency, with mild ectasis in the distal region. In July 2000, another valvulography showed a malfunction of the cystoperitoneal system. The distal catheter was surgically reviewed and repositioned. A few months of being asymptomatic, the headaches returned with a cough, which didn't respond to treatment. In February of 2002, she was referred to the Military Hospital Nuclear Medicine Department and a radionuclide valvulography was performed with 370 MBq of Tc99m-DTPA, injected in the derivative system reservoir. Images showed a slow descension of the radionuclide until the xifoides region where the distal catheter had formed a loop into the chest. Free activity was observed at the end of the catheter with another abnormal traject in the middle chest up to the top of the sternum. A pumping test was done and the patient coughed and said that she 'felt water' in her mouth. A simple abdomen X-ray was performed confirming the distal catheter in the upper side of the diaphragm. A third surgery was performed demonstrating that the catheter had an intraperitoneal loop with the distal end in the chest. They pulled the catheter and the distal end was repositioned into the peritoneal cavity, controlling its functioning. A simple abdomen X-ray verified the position. In the following days the patient had no headache

  2. Ectopic cystoperitoneal shunt demonstrated by valvulography. A case report

    International Nuclear Information System (INIS)

    Jofre, M.J.; Sierralta, M.P.

    2002-01-01

    The most important and frequent complications in the management of hydrocephalus treated with a derivation system are the infection and obstruction of the ventriculoperitoneal or ventriculoatrial shunt. However, another less frequent problem is the migration of the distal catheter. The case report presented is a 20 year-old girl who started, when she was 12, with severe headaches and epileptogenic seizures. She was diagnosed with a left parietotemporal aracnoidal cyst and a cystoperitoneal shunt was installed. However, she continued to have headaches. In September 1999, the derivation system was controlled with a radionuclide valvulography, which demonstrated shunt patency, with mild ectasis in the distal region. In July 2000, another valvulography showed a malfunction of the cystoperitoneal system. The distal catheter was surgically reviewed and repositioned. A few months of being asymptomatic, the headaches returned with a cough, which didn't respond to treatment. In February of 2002, she was referred to the Military Hospital Nuclear Medicine Department and a radionuclide valvulography was performed with 370 MBq of Tc99m-DTPA, injected in the derivative system reservoir. Images showed a slow descension of the radionuclide until the xifoides region where the distal catheter had formed a loop into the chest. Free activity was observed at the end of the catheter with another abnormal traject in the middle chest up to the top of the sternum. A pumping test was done and the patient coughed and said that she 'felt water' in her mouth. A simple abdomen X-ray was performed confirming the distal catheter in the upper side of the diaphragm. A third surgery was performed demonstrating that the catheter had an intraperitoneal loop with the distal end in the chest. They pulled the catheter and the distal end was repositioned into the peritoneal cavity, controlling its functioning. A simple abdomen X-ray verified the position. In the following days the patient had no headache

  3. Transjugular Intrahepatic Portosystemic Shunt Placement in Patients with Cirrhosis and Concomitant Portal Vein Thrombosis

    International Nuclear Information System (INIS)

    Ha, Thuong G. Van; Hodge, Justin; Funaki, Brian; Lorenz, Jonathan; Rosenblum, Jordan; Straus, Christopher; Leef, Jeff

    2006-01-01

    Purpose. To determine the safety and efficacy of transjugular intrahepatic portosystemic shunt (TIPS) creation in patients with liver cirrhosis complicated by thrombosed portal vein. Methods. This study reviewed 15 cases of TIPS creation in 15 cirrhotic patients with portal vein thrombosis at our institution over an 8-year period. There were 2 women and 13 men with a mean age of 53 years. Indications were refractory ascites, variceal hemorrhage, and refractory pleural effusion. Clinical follow-up was performed in all patients. Results. The technical success rate was 75% (3/4) in patients with chronic portal vein thrombosis associated with cavernomatous transformation and 91% (10/11) in patients with acute thrombosis or partial thrombosis, giving an overall success rate of 87%. Complications included postprocedural encephalopathy and localized hematoma at the access site. In patients with successful shunt placement, the total follow-up time was 223 months. The 30-day mortality rate was 13%. Two patients underwent liver transplantation at 35 days and 7 months, respectively, after TIPS insertion. One patient had an occluded shunt at 4 months with an unsuccessful revision. The remaining patients had functioning shunts at follow-up. Conclusion. TIPS creation in thrombosed portal vein is possible and might be a treatment option in certain patients

  4. An Adaptive Speed Control Approach for DC Shunt Motors

    Directory of Open Access Journals (Sweden)

    Ruben Tapia-Olvera

    2016-11-01

    Full Text Available A B-spline neural networks-based adaptive control technique for angular speed reference trajectory tracking tasks with highly efficient performance for direct current shunt motors is proposed. A methodology for adaptive control and its proper training procedure are introduced. This algorithm sets the control signal without using a detailed mathematical model nor exact values of the parameters of the nonlinear dynamic system. The proposed robust adaptive tracking control scheme only requires measurements of the velocity output signal. Thus, real-time measurements or estimations of acceleration, current and disturbance signals are avoided. Experimental results confirm the efficient and robust performance of the proposed control approach for highly demanding motor operation conditions exposed to variable-speed reference trajectories and completely unknown load torque. Hence, laboratory experimental tests on a direct current shunt motor prove the viability of the proposed adaptive output feedback trajectory tracking control approach.

  5. Draft genome sequence of Actinotignum schaalii DSM 15541T: Genetic insights into the lifestyle, cell fitness and virulence.

    Directory of Open Access Journals (Sweden)

    Atteyet F Yassin

    Full Text Available The permanent draft genome sequence of Actinotignum schaalii DSM 15541T is presented. The annotated genome includes 2,130,987 bp, with 1777 protein-coding and 58 rRNA-coding genes. Genome sequence analysis revealed absence of genes encoding for: components of the PTS systems, enzymes of the TCA cycle, glyoxylate shunt and gluconeogensis. Genomic data revealed that A. schaalii is able to oxidize carbohydrates via glycolysis, the nonoxidative pentose phosphate and the Entner-Doudoroff pathways. Besides, the genome harbors genes encoding for enzymes involved in the conversion of pyruvate to lactate, acetate and ethanol, which are found to be the end products of carbohydrate fermentation. The genome contained the gene encoding Type I fatty acid synthase required for de novo FAS biosynthesis. The plsY and plsX genes encoding the acyltransferases necessary for phosphatidic acid biosynthesis were absent from the genome. The genome harbors genes encoding enzymes responsible for isoprene biosynthesis via the mevalonate (MVA pathway. Genes encoding enzymes that confer resistance to reactive oxygen species (ROS were identified. In addition, A. schaalii harbors genes that protect the genome against viral infections. These include restriction-modification (RM systems, type II toxin-antitoxin (TA, CRISPR-Cas and abortive infection system. A. schaalii genome also encodes several virulence factors that contribute to adhesion and internalization of this pathogen such as the tad genes encoding proteins required for pili assembly, the nanI gene encoding exo-alpha-sialidase, genes encoding heat shock proteins and genes encoding type VII secretion system. These features are consistent with anaerobic and pathogenic lifestyles. Finally, resistance to ciprofloxacin occurs by mutation in chromosomal genes that encode the subunits of DNA-gyrase (GyrA and topisomerase IV (ParC enzymes, while resistant to metronidazole was due to the frxA gene, which encodes NADPH

  6. Immunohistochemical analysis of restenotic tissue after transjugular portosystemic shunt

    International Nuclear Information System (INIS)

    Lu Qin; An Yanli; Deng Gang; Fang Wen; Zhu Guangyu; Li Guozhao; Wei Xiaoying; Liu Yuanyuan; Teng Gaojun

    2005-01-01

    Objective: To investigate the changes of several restenotic tissue elements after transjugular portosystemic shunt, and to provide more informations for the mechanism of TIPS restenosis. Methods: TIPS was performed in 6 swine to set up TIPS animal models. 14-21 days after operation, the models were sacrificed to obtain the TIPS tissues for pathological examinations, including electric microscope, HE staining, and immunohistochemical staining of anti-SMC-actin-α, PCNA, Vementin, myoglobulin, eNOS and iNOS. Then , the results were comparatively analyzed between TIPS obstructed shunt tissues and non-obstructed shunt tissues. Results: Restenosis was occurred with different degrees in 4 swine of the 6 TIPS models. Electric microscopic results showed that the restenosis tissues were composed of over proliferated collagen, SMCs and fibroblasts. Anti-SMC-actin-α and PCNA were strongly positive expression in restenotic tissues, and also positive in patent tissues. Vimentin expressed strongly in unstenotic tissues, on the contrary, it expressed obviously weaker in restenotic tissues. Myoglobulin expressed more strongly in restenotic tissues and weakened in unstenotic tissues. eNOS expressed positive in normal liver tissues, and expressed weaker near TIPS restenotic tissues. iNOS showed stronger expression in restenotic tissues and could hardly expressed in normal liver tissues. Conclusions: Restenotic rate may be 67% in TIPS swine models. Restenotic tissues may be mainly composed of proliferated SMCs positively expressed anti-SMC-actin-α with strong ability of movement. eNOS may be expressed in normal liver tissues and instead iNOS be expressed in strongly injured liver tissues. (authors)

  7. GABA shunt in the callus cells derived from soybean cotyledon

    Energy Technology Data Exchange (ETDEWEB)

    Tokunaga, M; Nakano, Y; Kitaoka, S [Osaka Prefectural Univ., Sakai (Japan). Coll. of Agriculture

    1975-01-01

    In the growing callus cells from soybean cotyledon, the activities of glutamate decarboxylase and GABA transaminase were increased in the early phase of the callus growth on the Miller agar medium. Succinate dehydrogenase activity was also changed in a similar manner. From these and the additional evidences that GABA transaminase was probably localized in the mitochondria, it has been made clear that the GABA shunt (GABA by-pass pathway) is operative and contributes to the respiratory metabolism in growing callus cells. Feeding young callus cells with GABA-U-/sup 14/C for 24 hr actually resulted in finding 53% of the taken up radioactivity in released carbon dioxide. Considerable parts of the taken up radioactivity were found in amino acids and proteins which should have been formed via the GABA shunt also.

  8. Does a meso-caval shunt have positive effects in a pig large-for-size liver transplantation model?

    Science.gov (United States)

    Tannuri, Ana Cristina Aoun; de Albuquerque Rangel Moreira, Daniel; Belon, Alessandro; Coelho, Maria Cecília Mendonça; Gonçalves, Josiane Oliveira; Serafini, Suellen; Tannuri, Uenis

    2017-08-01

    In pediatric liver transplantations with LFS grafts, higher incidences of graft dysfunction probably occur due to IRI. It was postulated that increasing the blood supply to the graft by means of a meso-caval shunt could ameliorate the IRI. Eleven pigs underwent liver transplantation and were divided into two groups: LFS and LFS+SHUNT group. A series of flowmetric, metabolic, histologic, and molecular studies were performed. No significant metabolic differences were observed between the groups. One hour after reperfusion, portal flow was significantly lower in the recipients than in the donors, proving that the graft was maintained in low portal blood flow, although the shunt could promote a transient increase in the portal blood flow and a decrease in the arterial flow. Finally, it was verified that the shunt promoted a decrease in inflammation and steatosis scores and a decrease in the expression of the eNOS gene (responsible for the generation of nitric oxide in the vascular endothelium) and an increase in the expression of the proapoptotic gene BAX. The meso-caval shunt was responsible for some positive effects, although other deleterious flowmetric and molecular alterations also occurred. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Measurement of shunt amount using radionuclide angiocardiography: accuracy according to level of shunt and associated lesion

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yang Min [Sejong General Hospital, Bucheon (Korea, Republic of)

    2006-08-15

    Determination of pulmonary to systemic blood flow ratio (QP/QS) is important for the management of patients with left-to-right shunt. This study was performed to assess the agreement of Qp/Qs ratio using the radionuclide method and oxymetry, to investigate the factors influencing the agreement, and to know how interchangeable the results of each technique. We compared the Qp/Qs measured by single-pass radionuclide angiocardiography and oxymetry during catheterization in 207 patients who underwent both studies. In radionuclide method, Qp/Qs was calculated from the pulmonary time-activity curves using a gamma variate fit. The correlation and Bland-Altman analysis were performed according to the levels of shunt and associated lesions. The mean Qp/Qs was 1.83 {+-} 0.50 by radionuclide, and 1.74 {+-} 0.51 by oxymetry. The overall correlation coefficient was 0.86 ({rho} 0.001), and Bland-Altman range of agreement encompassing 4SD was 1.05. For atrial septal defect, ventricular septal defect, patent ductus arteriosus, tricuspid and mitral insufficiency, the correlation coefficient was 0.78, 0.90, 0.84, 0.63 and 0.44 and Bland-Altman range was 1.52, 0.74, 0.96, 1.57 and 1.50, respectively. There is good agreement but wide variance between the Qp/Qs ratios by radionuclide method and oxymetry. Associated atrioventricular valvar insufficiency decreases the correlation coefficient and widens the variance. Wide overall variance suggests that Qp/Qs measurements by two techniques should not be used interchangeably.

  10. Measurement of shunt amount using radionuclide angiocardiography: accuracy according to level of shunt and associated lesion

    International Nuclear Information System (INIS)

    Kim, Yang Min

    2006-01-01

    Determination of pulmonary to systemic blood flow ratio (QP/QS) is important for the management of patients with left-to-right shunt. This study was performed to assess the agreement of Qp/Qs ratio using the radionuclide method and oxymetry, to investigate the factors influencing the agreement, and to know how interchangeable the results of each technique. We compared the Qp/Qs measured by single-pass radionuclide angiocardiography and oxymetry during catheterization in 207 patients who underwent both studies. In radionuclide method, Qp/Qs was calculated from the pulmonary time-activity curves using a gamma variate fit. The correlation and Bland-Altman analysis were performed according to the levels of shunt and associated lesions. The mean Qp/Qs was 1.83 ± 0.50 by radionuclide, and 1.74 ± 0.51 by oxymetry. The overall correlation coefficient was 0.86 (ρ 0.001), and Bland-Altman range of agreement encompassing 4SD was 1.05. For atrial septal defect, ventricular septal defect, patent ductus arteriosus, tricuspid and mitral insufficiency, the correlation coefficient was 0.78, 0.90, 0.84, 0.63 and 0.44 and Bland-Altman range was 1.52, 0.74, 0.96, 1.57 and 1.50, respectively. There is good agreement but wide variance between the Qp/Qs ratios by radionuclide method and oxymetry. Associated atrioventricular valvar insufficiency decreases the correlation coefficient and widens the variance. Wide overall variance suggests that Qp/Qs measurements by two techniques should not be used interchangeably

  11. Studies on the nature of intermediates in enzyme mechanisms

    International Nuclear Information System (INIS)

    Clark, J.D.

    1988-01-01

    The reaction pathway followed by malate synthase has been studied by the double isotope fractionation method to determine whether the reaction is stepwise or concerted. A primary deuterium kinetic isotope effect ( D V/K) of 1.3 ± 0.1 has been found using [ 2 H 3 ]acetyl-CoA as substrate. The 13 C isotope effect at the aldehydic carbon of glyoxylate has also been measured. For this determination, the malate product was quantitatively transformed into a new sample of malate having the carbon of interest at C-4. This material was decarboxylated to produce the appropriate CO 2 for isotope ratio mass spectrometric analysis. If the essential Zn(II) ion of yeast aldolase interacts with the carbonyl groups of bound substrates, we can expect that these will be more reactive toward reduction by borohydrides than those free in solution. Tritiated sodium borohydride was therefore used to reduce the substrates of yeast aldolase in the presence and absence of enzyme, and the enantiomeric and diastereomeric ratios of the products were analyzed. Experiments were conducted in an effort to distinguish between endocyclic and exocyclic cleavage in the hydrolysis catalyzed by lysozyme. Tritiated sodium borohydride was used in an attempt to trap the putative oxocarbonium intermediate

  12. Unsuccessful lung scan due to major right-to-left shunt through a sinus venosus septal defect

    International Nuclear Information System (INIS)

    Brendel, A.J.; Larnaudie, B.; Lambert, B.; Leccia, F.; Barat, J.L.; Ducassou, D.; Fontan, F.

    1985-01-01

    In a patient with a prior history of cerebral abscess and cerebral ischemia, an unsuccessful perfusion lung scan led to a radionuclide angiocardiogram using an arm vein injection. This showed a total right-to-left (R-L) shunt from the superior vena cava (SVC) to the left atrium. Repeat radionuclide study, through a leg vein, demonstrated a moderate R-L shunt and an interpretable lung scan could be obtained. Catheterization and contrast cineangiogram did not provide the exact diagnosis, the preoperative conclusion being anomalous drainage of the SVC into the left atrium, with atrial septal defect (ASD) and partial anomalous pulmonary venous connection to the SVC. The operative diagnosis was high atrial (sinus venosus) septal defect. This example of major but clinically unsuspected R-L shunt emphasizes the value of performing a perfusion lung scan, preferably in conjunction with radionuclide angiocardiography in patients with a prior history of unexplained cerebral abscess or systemic ischemia. Implications of the site of an ASD on quantitation of L-R shunts by radionuclide methods are also discussed

  13. Passive acoustic radiation control for a vibrating panel with piezoelectric shunt damping circuit using particle swarm optimization algorithm

    International Nuclear Information System (INIS)

    Jeon, Jin Young

    2009-01-01

    This paper presents a new acoustic radiation optimization method for a vibrating panel-like structure with a passive piezoelectric shunt damping system in order to minimize well-radiating modes generated from the panel. The optimization method is based on an idea of using the p-version finite element method(p-version FEM), the boundary element method(BEM), and the particle swarm optimization algorithm(PSOA). Optimum embossment design for the vibrating panel using the PSOA is first investigated in order to minimize noise radiation over a frequency range of interest. The optimum embossment design works as a kind of stiffener so that well-radiating natural modes are shifted up with some degrees. The optimized panel, however, may still require additional damping for attenuating the peak acoustic amplitudes. A passive shunt damping system is thus employed to additionally damp the well-radiating modes from the optimized panel. To numerically evaluate the acoustic multiple-mode damping capability by a shunt damping system, the integrated p-version FEM/BEM for the panel with the shunt damping system is modeled and developed by MATLAB. Using the PSOA, the optimization technique for the optimal multiple-mode shunt damper is investigated in order to achieve the optimum damping performance for the well-radiating modes simultaneously. Also, the acoustic damping performance of the shunt damping circuit in the acoustic environment is demonstrated numerically and experimentally with respect to the realistically sized panel. The simulated result shows a good agreement with that of the experimental result

  14. Harmonics reduction in standalone DFIG-DC system by shunt active ...

    Indian Academy of Sciences (India)

    Himanshu Misra

    2018-05-22

    May 22, 2018 ... Doubly fed induction generator; standalone; DC voltage regulation; shunt active filter; harmonics ... Operation and design issue of DFIG in DC-net interface is ...... control systems for the operation of DFIGs in wind energy.

  15. Shunting outcomes in posthemorrhagic hydrocephalus: results of a Hydrocephalus Clinical Research Network prospective cohort study.

    Science.gov (United States)

    Wellons, John C; Shannon, Chevis N; Holubkov, Richard; Riva-Cambrin, Jay; Kulkarni, Abhaya V; Limbrick, David D; Whitehead, William; Browd, Samuel; Rozzelle, Curtis; Simon, Tamara D; Tamber, Mandeep S; Oakes, W Jerry; Drake, James; Luerssen, Thomas G; Kestle, John

    2017-07-01

    OBJECTIVE Previous Hydrocephalus Clinical Research Network (HCRN) retrospective studies have shown a 15% difference in rates of conversion to permanent shunts with the use of ventriculosubgaleal shunts (VSGSs) versus ventricular reservoirs (VRs) as temporization procedures in the treatment of hydrocephalus due to high-grade intraventricular hemorrhage (IVH) of prematurity. Further research in the same study line revealed a strong influence of center-specific decision-making on shunt outcomes. The primary goal of this prospective study was to standardize decision-making across centers to determine true procedural superiority, if any, of VSGS versus VR as a temporization procedure in high-grade IVH of prematurity. METHODS The HCRN conducted a prospective cohort study across 6 centers with an approximate 1.5- to 3-year accrual period (depending on center) followed by 6 months of follow-up. Infants with premature birth, who weighed less than 1500 g, had Grade 3 or 4 IVH of prematurity, and had more than 72 hours of life expectancy were included in the study. Based on a priori consensus, decisions were standardized regarding the timing of initial surgical treatment, upfront shunt versus temporization procedure (VR or VSGS), and when to convert a VR or VSGS to a permanent shunt. Physical examination assessment and surgical technique were also standardized. The primary outcome was the proportion of infants who underwent conversion to a permanent shunt. The major secondary outcomes of interest included infection and other complication rates. RESULTS One hundred forty-five premature infants were enrolled and met criteria for analysis. Using the standardized decision rubrics, 28 infants never reached the threshold for treatment, 11 initially received permanent shunts, 4 were initially treated with endoscopic third ventriculostomy (ETV), and 102 underwent a temporization procedure (36 with VSGSs and 66 with VRs). The 2 temporization cohorts were similar in terms of sex, race

  16. Shunt malfunction causing acute neurological deterioration in 2 patients with previously asymptomatic Chiari malformation Type I. Report of two cases.

    Science.gov (United States)

    Elliott, Robert; Kalhorn, Stephen; Pacione, Donato; Weiner, Howard; Wisoff, Jeffrey; Harter, David

    2009-08-01

    Patients with symptomatic Chiari malformation Type I (CM-I) typically exhibit a chronic, slowly progressive disease course with evolution of symptoms. However, some authors have reported acute neurological deterioration in the setting of CM-I and acquired Chiari malformations. Although brainstem dysfunction has been documented in patients with CM-II and hydrocephalus or shunt malfunction, to the authors' knowledge only 1 report describing ventriculoperitoneal (VP) shunt malfunction causing neurological deterioration in a patient with CM-I exists. The authors report on their experience with the treatment of previously asymptomatic CM-I in 2 children who experienced quite different manifestations of acute neurological deterioration secondary to VP shunt malfunction. Presumably, VP shunt malfunction created a positive rostral pressure gradient across a stenotic foramen magnum, resulting in tetraparesis from foramen magnum syndrome in 1 patient and acute ataxia and cranial nerve deficits from syringobulbia in the other. Although urgent shunt revisions yielded partial recovery of neurological function in both patients, marked improvement occurred only after posterior fossa decompression.

  17. Transjugular Intrahepatic Portosystemic Shunts in Children with Biliary Atresia

    International Nuclear Information System (INIS)

    Huppert, Peter E.; Goffette, Pierre; Astfalk, Wolfgang; Sokal, Emil M.; Brambs, Hans-Juergen; Schott, Ullrich; Duda, Stephan H.; Schweizer, Paul; Claussen, Claus D.

    2002-01-01

    Purpose: We retrospectively evaluated the technical and long-term clinical results of transjugularintrahepatic portosystemic shunts (TIPS) in children with portal hypertension and biliary atresia (BA). Methods: Nine children with BA and recurrent bleeding from esophagogastric and/or intestinal varices were treated by TIPS at the age of 34-156 months and followed-up in two centers. Different types of stents were used. Results: Shunt insertion succeeded in all patients, but in two a second procedure was necessary. Seven procedures lasted more than 3 hr, mainly due to difficult portal vein puncture.Variceal bleeding ceased in all patients; however, 16 reinterventions were performed in eight patients for clinical reasons (n =11) and sonographically suspected restenosis (n =5). Four patients underwent successful liver transplantation 4-51 months after TIPS and five are in good clinical conditions 64-75 months after TIPS. Conclusions: TIPS in children with BA is technically difficult, mainly due to periportal fibrosis and small portal veins. Frequency of reinterventions seems to be higher compared with adults

  18. Surgical approach for systemic-pulmonary shunt in neonates with functionally univentricular heart: comparison between sternotomy and thoracotomy.

    Science.gov (United States)

    Sasaki, Takashi; Takeda, Yuko; Ohnakatomi, Yasuko; Asou, Toshihide

    2016-09-01

    The preferred surgical approach for systemic-pulmonary shunts has changed from thoracotomy to sternotomy in our institution, to concomitantly manage the ductus arteriosus during surgery. The purpose of this study was to compare the outcomes of systemic-pulmonary shunts for neonates with functionally univentricular hearts based on surgical approach. Fifty-two neonates with functionally univentricular hearts underwent systemic-pulmonary shunt via sternotomy (n = 28) or thoracotomy (n = 24). Patient characteristics, achievement rates of right heart bypass, and survival rates were compared for the different approaches. Prenatal diagnosis was made more common in the sternotomy group (p = 0.006). The shunt was placed more centrally in the sternotomy group. The ductus arteriosus was ligated or banded in most patients in the sternotomy group (26/28) and in a few patients in the thoracotomy group (6/24). Frequency of ductal management in the early postoperative phase was not different between the groups (21 vs 25 %), but three new incisions had to be made in the thoracotomy group. No differences were seen in the achievement rates of bidirectional cavopulmonary shunts (86 vs 87 % at 10 months of age) and total cavopulmonary connection (81 vs 81 % at 2 years of age), or in the survival rates (92 vs 96 % at 8 years). There were no differences in short- and long-term outcomes between the groups. The sternotomy approach might be preferable in the current era of prenatal diagnosis, to allow simultaneous duct management during systemic-pulmonary shunt surgery, particularly in patients with large ducts associated with functionally univentricular hearts.

  19. Comparison of Acute Thrombogenicity for Metallic and Polymeric Bioabsorbable Scaffolds: Magmaris Versus Absorb in a Porcine Arteriovenous Shunt Model.

    Science.gov (United States)

    Waksman, Ron; Lipinski, Michael J; Acampado, Eduardo; Cheng, Qi; Adams, Lila; Torii, Sho; Gai, Jiaxiang; Torguson, Rebecca; Hellinga, David M; Westman, Peter C; Joner, Michael; Zumstein, Philine; Kolodgie, Frank D; Virmani, Renu

    2017-08-01

    A comparison in acute thrombogenicity between the Magmaris sirolimus-eluting bioabsorbable magnesium scaffold and the Absorb bioresorbable vascular scaffold has not been performed. This study assessed acute thrombogenicity of Magmaris compared with Absorb and the Orsiro hybrid drug-eluting stent in a porcine arteriovenous shunt model. An ex vivo porcine carotid jugular arteriovenous shunt was established and connected to SYLGARD tubing containing the Magmaris, Absorb, and Orsiro scaffolds/stents and allowed to run in the shunt for a maximum of 1 hour. Twelve shunts (2 shunt runs per pig) were run comparing the 3 scaffolds in alternating order. Nested generalized linear mixed models were used to compare variables between scaffold groups while adjusting for variability between shunt runs. Confocal fluorescent microscopy costaining CD61/CD42b demonstrated that both Magmaris (3.0%) and Orsiro (4.6%) had less platelet coverage of the total scaffold compared with Absorb (21.8%). Scanning electron microscopy demonstrated significantly less thrombus deposition to Magmaris as a percentage of the total scaffold compared with Absorb (5.0% versus 16.1%, P =0.02). Magmaris had significantly less PM-1-positive neutrophil and CD14-positive monocyte adherence compared with both Orsiro and Absorb. Orsiro had significantly less monocyte deposition compared with Absorb. Despite a similar scaffold strut thickness, the Magmaris sirolimus-eluting bioabsorbable magnesium scaffold was significantly less thrombogenic compared with the Absorb bioresorbable vascular scaffold in an ex vivo porcine arteriovenous shunt model. Further studies are needed to determine whether the reduced thrombogenicity of Magmaris will result in reductions in major cardiovascular events. © 2017 American Heart Association, Inc.

  20. Metformin reduces intrahepatic fibrosis and intrapulmonary shunts in biliary cirrhotic rats

    Directory of Open Access Journals (Sweden)

    Mu-Tzu Ko

    2017-08-01

    Conclusion: Metformin reduced liver injury and improved hepatic fibrosis in cirrhotic rats. It also attenuated the intrapulmonary shunts. However, the effects of metformin on pulmonary angiogenesis and hypoxia were insignificant.

  1. Endoscopic third ventriculostomy has no higher costs than ventriculoperitoneal shunt

    Directory of Open Access Journals (Sweden)

    Benicio Oton de Lima

    2014-07-01

    Full Text Available Objective: To evaluate the cost of endoscopic third ventriculostomy (ETV compared to ventriculoperitoneal shunt (VPS in the treatment of hydrocephalus in children. Method: We studied 103 children with hydrocephalus, 52 of which were treated with ETV and 51 with VPS in a prospective cohort. Treatment costs were compared within the first year after surgery, including subsequent surgery or hospitalization. Results: Twenty (38.4% of the 52 children treated with VPS needed another procedure due to shunt failure, compared to 11 (21.5% of 51 children in the ETV group. The average costs per patient in the group treated with ETV was USD$ 2,177,66±517.73 compared to USD$ 2,890.68±2,835.02 for the VPS group. Conclusions: In this series there was no significant difference in costs between the ETV and VPS groups.

  2. Novel type of peritoneocentesis trocar-assisted distal ventriculoperitoneal shunt placement with supervision via a one-port laparoscope.

    Science.gov (United States)

    Wang, Guangming; Yu, Jinlu; Luan, Yongxin; Han, Yanwu; Fu, Shuanglin

    2017-10-01

    Ventriculoperitoneal shunts (VPS) are the primary treatment for hydrocephalus and are associated with a high risk of complications, specifically in patients who are obese or have abdominal adhesions or shunt revisions. The present study describes the use of a novel type of peritoneal catheter peritoneocentesis trocar insertion with the assistance of a one-port laparoscope. A total of 36 patients with hydrocephalus underwent this novel type of peritoneocentesis trocar-assisted VPS. The distal shunt catheter was placed into the right subdiaphragmatic space and the catheter was traversed through a single hole drilled through the liver falciform ligament. The duration of the laparoscopic surgery ranged from 6-18 min (mean 10.4±1.6 min). No shunt-related infections or catheter malfunctions or injuries to the intra-abdominal organs occurred. The total abdominal incision length was 1.0 cm (0.5+0.5 cm). No laparoscopy-related complications were observed during follow-up assessments. The novel approach used in the current study is very easy to perform, and this method may significantly reduce the risk of malfunction complications. The presented method also has the advantages of reduced trauma and a simpler surgery. The current study indicated that this simple, minimally invasive procedure was beneficial for patients with hydrocephalus, specifically in cases of patients with obesity, peritoneal adhesions or shunt revisions.

  3. Reversibility of hyperintense globus pallidus on T 1-weighted MRI following surgery for a portosystemic shunt in an 8-year-old girl

    International Nuclear Information System (INIS)

    Ikeda, Shinji; Sera, Yoshihisa; Yoshida, Mituhiro; Ohshiro, Hajime; Uchino, Shinichiro; Seguchi, Sasa; Endo, Fumio

    1999-01-01

    An 8-year-old Japanese girl with a portosystemic shunt had shown hyperammonaemia since she was 3 years of age. MRI of her brain showed bilateral hyperintense globus pallidus. A portosystemic shunt was evident on US and angiography. She underwent surgical banding of the shunt, after which the lesion and clinical symptoms disappeared. (orig.)

  4. The G6. A heavy-duty, six-wheeled shunting locomotive

    Energy Technology Data Exchange (ETDEWEB)

    Hildebrandt, Tim [Vossloh Locomotives GmbH, Kiel (Germany). Development and Standardisation Group

    2010-05-15

    Nowadays, railway operating companies need robust, reliable and versatile locomotives. Vossloh has shown one way that future developments are likely to go with its 'G6' six-wheeled shunting locomotive, which features a central driver's cab. (orig.)

  5. Flux analysis of central metabolic pathways in Geobactermetallireducens during reduction of solubleFe(III)-NTA

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Yinjie J.; Chakraborty, Romy; Garcia-Martin, Hector; Chu,Jeannie; Hazen, Terry C.; Keasling, Jay D.

    2007-01-01

    We analyzed the carbon fluxes in the central metabolism ofGeobacter metallireducens strain GS-15 using 13C isotopomer modeling.Acetate labeled in the 1st or 2nd position was the sole carbon source,and Fe-NTA was the sole terminal electron acceptor. The measured labeledacetate uptake rate was 21 mmol/gdw/h in the exponential growth phase.The resulting isotope labeling pattern of amino acids allowed an accuratedetermination of the in vivo global metabolic reaction rates (fluxes)through the central metabolic pathways using a computational isotopomermodel. The tracer experiments showed that G. metallireducens containedcomplete biosynthesis pathways for essential metabolism, and this strainmight also have an unusual isoleucine biosynthesis route (usingacetyl-CoA and pyruvate as the precursors). The model indicated that over90 percent of the acetate was completely oxidized to CO2 via a completetricarboxylic acid (TCA) cycle while reducing iron. Pyruvate carboxylaseand phosphoenolpyruvate carboxykinase were present under theseconditions, but enzymes in the glyoxylate shunt and malic enzyme wereabsent. Gluconeogenesis and the pentose phosphate pathway were mainlyemployed for biosynthesis and accounted for less than 3 percent of totalcarbon consumption. The model also indicated surprisingly highreversibility in the reaction between oxoglutarate and succinate. Thisstep operates close to the thermodynamic equilibrium possibly becausesuccinate is synthesized via a transferase reaction, and the conversionof oxoglutarate to succinate is a rate limiting step for carbonmetabolism. These findings enable a better understanding of therelationship between genome annotation and extant metabolic pathways inG. metallireducens.

  6. The Association Between Ventriculo-Peritoneal Shunt and Acute Appendicitis in Patients with Traumatic Brain Injury: A 14-Year, Population-Based Study.

    Science.gov (United States)

    Lim, Sher-Wei; Ao, Kam-Hou; Ho, Chung-Han; Tseng, Chien-Jen; Wang, Jhi-Joung; Chio, Chung-Ching; Kuo, Jinn-Rung

    2017-07-01

    The association between preexisting ventriculoperitoneal (VP) shunt and the risk of new-onset acute appendicitis in patients with traumatic brain injury (TBI) is not well established. The aim of the present study was to determine the relationships between VP shunt and acute appendicitis in patients with TBI. A longitudinal cohort study matched by a propensity score in patients with TBI with (4781 patients) or without (9562 patients) VP shunt was conducted using the National Health Insurance Research Database in Taiwan between January 1993 and December 2013. The main outcome studied was diagnosis of acute appendicitis. The cumulative probability of acute appendicitis was not different between these 2 groups (P = 0.6244). A Cox model showed central nervous system (CNS) infection to be an independent predictor of acute appendicitis with an adjusted hazard ratio of 2.98. Patients with TBI with both a VP shunt and a CNS infection had a greater risk of developing new-onset acute appendicitis (hazard ratio 4.25; 95% confidence interval 1.84-9.81) compared patients with TBI without a VP shunt or CNS infection. We concluded that VP shunt is not a risk factor in the development of appendicitis in patients with TBI. Patients with TBI with a shunt and a CNS infection may have a greater risk of developing acute appendicitis. Therefore, care in avoiding CNS infection is a key for the prevention acute appendicitis in this patient population. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Correlation of dynamic parameter modification and ASET sensitivity in a shunt voltage reference

    International Nuclear Information System (INIS)

    Roche, N.J.H.; Buchner, S.P.; Warner, J.H.; McMorrow, D.; Dusseau, L.; Boch, J.; Saigne, F.; Kruckmeyer, K.; Auriel, G.; Azais, B.

    2012-01-01

    Analog Single Event Transients (ASETs) in two different shunt voltage references used in power management systems are investigated. Little has been published regarding how the dynamic parameter changes induced by external circuit design, such as time constant, damping coefficient or natural frequency affect ASET shapes. Modifications of the dynamic parameters of the circuit are measured by step response measurement. A correlation between dynamic parameters and ASET laser testing results is proposed. This study establishes the correlation between the dynamic parameters of a shunt voltage reference and ASET parameters such as pulse duration, and positive and negative amplitude. (authors)

  8. Temporary vascular shunting in vascular trauma: A 10-year review ...

    African Journals Online (AJOL)

    of a physiologically unstable patient requiring a damage control procedure, and in the ... ensure that the tubing would not fall out, but not so tight that the lumen of the .... Time to removal of the shunt represents a balance between removing the ...

  9. Effects of an interatrial shunt on rest and exercise hemodynamics

    DEFF Research Database (Denmark)

    Kaye, David; Shah, Sanjiv J; Borlaug, Barry A

    2014-01-01

    BACKGROUND: A treatment based on an interatrial shunt device has been proposed for counteracting elevated pulmonary capillary wedge pressure (PCWP) in patients with heart failure and mildly reduced or preserved ejection fraction (HFpEF). We tested the theoretical hemodynamic effects of this appro...

  10. Anatomical Evidence for Intracardiac Blood Shunting in Marine Turtles

    African Journals Online (AJOL)

    ... suggests that right to left intra-cardiac blood shunts may be a feature of diving in sea turtles; the sphincter providing a mechanism for the control of blood flow through the heart. The comparative anatomy of the pulmonary arteries of selected terrestrial reptiles suggests that a similar mechanism exists in non-diving species.

  11. Transcatheter Potts shunt creation in patients with severe pulmonary arterial hypertension: initial clinical experience.

    Science.gov (United States)

    Esch, Jesse J; Shah, Pinak B; Cockrill, Barbara A; Farber, Harrison W; Landzberg, Michael J; Mehra, Mandeep R; Mullen, Mary P; Opotowsky, Alexander R; Waxman, Aaron B; Lock, James E; Marshall, Audrey C

    2013-04-01

    Patients with severe pulmonary arterial hypertension (PAH) face significant morbidity and death as a consequence of progressive right heart failure. Surgical shunt placement between the left PA and descending aorta (Potts shunt) appears promising for PAH palliation in children; however, surgical mortality is likely to be unacceptably high in adults with PAH. We describe a technique for transcatheter Potts shunt (TPS) creation by fluoroscopically guided retrograde needle perforation of the descending aorta at the site of apposition to the left PA to create a tract for deployment of a covered stent between these vessels. This covered stent-anchored by the vessel walls and surrounding tissue-serves as the shunt. TPS creation was considered in 7 patients and performed in 4. The procedure was technically successful in 3 patients; 1 patient died during the procedure as a result of uncontrolled hemothorax. One acute survivor, critically ill at the time of TPS creation, later died of comorbidities. The 2 mid-term survivors (follow-up of 10 and 4 months) are well at home, with symptomatic improvement and no late complications. The 3 candidate patients in whom the procedure was not performed died within 1 month of consideration, underscoring the tenuous nature of this population. TPS creation is feasible and may offer symptomatic relief to select patients with refractory PAH. Further study of this innovative approach is warranted. Copyright © 2013 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  12. The GABA shunt in the callus cells derived from soybean cotyledon

    International Nuclear Information System (INIS)

    Tokunaga, Masao; Nakano, Yoshihisa; Kitaoka, Shozaburo

    1975-01-01

    In the growing callus cells from soybean cotyledon, the activities of glutamate decarboxylase and GABA transaminase were increased in the early phase of the callus growth on the Miller agar medium. Succinate dehydrogenase activity was also changed in a similar manner. From these and the additional evidences that GABA transaminase was probably localized in the mitochondria, it has been made clear that the GABA shunt (GABA by-pass pathway) is operative and contributes to the respiratory metabolism in growing callus cells. Feeding young callus cells with GABA-U- 14 C for 24 hr actually resulted in finding 53% of the taken up radioactivity in released carbon dioxide. Considerable parts of the taken up radioactivity were found in amino acids and proteins which should have been formed via the GABA shunt also. (auth.)

  13. Impact of Serum Vancomycin Trough Levels in the Treatment of Central Nervous System Shunt Infections Caused by Coagulase-Negative Staphylococci.

    Science.gov (United States)

    Gibson, Ashley; Kaplan, Sheldon L; Vallejo, Jesus G

    2018-04-26

    Coagulase-negative staphylococci (CoNS) are a common cause of pediatric ventricular shunt infections. The Infectious Diseases Society of America recommends vancomycin serum troughs of 15-20 µg/mL when treating CoNS shunt infections in adult patients. We report a series of pediatric cases of CoNS shunt infections in which clinical cure was obtained with troughs < 15 µg/mL. These findings question the relevance of this recommendation in pediatric patients. © 2018 S. Karger AG, Basel.

  14. Shunted-Josephson-junction model. I. The autonomous case

    DEFF Research Database (Denmark)

    Belykh, V. N.; Pedersen, Niels Falsig; Sørensen, O. H.

    1977-01-01

    The shunted-Josephson-junction model: the parallel combination of a capacitance, a phase-dependent conductance, and an ideal junction element biased by a constant current, is discussed for arbitrary values of the junction parameters. The main objective is to provide a qualitative understanding...... current-voltage curves are presented. The case with a time-dependent monochromatic bias current is treated in a similar fashion in the companion paper....

  15. Relationship of cerebral blood flow to aortic-to-pulmonary collateral/shunt flow in single ventricles

    Science.gov (United States)

    Fogel, Mark A; Li, Christine; Wilson, Felice; Pawlowski, Tom; Nicolson, Susan C; Montenegro, Lisa M; Berenstein, Laura Diaz; Spray, Thomas L; Gaynor, J William; Fuller, Stephanie; Keller, Marc S; Harris, Matthew A; Whitehead, Kevin K; Clancy, Robert; Elci, Okan; Bethel, Jim; Vossough, Arastoo; Licht, Daniel J

    2016-01-01

    Objective Patients with single ventricle can develop aortic-to-pulmonary collaterals (APCs). Along with systemic-to-pulmonary artery shunts, these structures represent a direct pathway from systemic to pulmonary circulations, and may limit cerebral blood flow (CBF). This study investigated the relationship between CBF and APC flow on room air and in hypercarbia, which increases CBF in patients with single ventricle. Methods 106 consecutive patients with single ventricle underwent 118 cardiac magnetic resonance (CMR) scans in this cross-sectional study; 34 prior to bidirectional Glenn (BDG) (0.50±0.30 years old), 50 prior to Fontan (3.19±1.03 years old) and 34 3–9 months after Fontan (3.98±1.39 years old). Velocity mapping measured flows in the aorta, cavae and jugular veins. Analysis of variance (ANOVA) and multiple linear regression were used. Significance was p<0.05. Results A strong inverse correlation was noted between CBF and APC/shunt both on room air and with hypercarbia whether CBF was indexed to aortic flow or body surface area, independent of age, cardiopulmonary bypass time, Po2 and Pco2 (R=−0.67–−0.70 for all patients on room air, p<0.01 and R=−0.49–−0.90 in hypercarbia, p<0.01). Correlations were not different between surgical stages. CBF was lower, and APCs/shunt flow was higher prior to BDG than in other stages. Conclusions There is a strong inverse relationship between CBF and APC/shunt flow in patients with single ventricle throughout surgical reconstruction on room air and in hypercarbia independent of other factors. We speculate that APC/shunt flow may have a negative impact on cerebral development and neurodevelopmental outcome. Interventions on APC may modify CBF, holding out the prospect for improving neurodevelopmental trajectory. Trial Registration Number NCT02135081. PMID:26048877

  16. Usefulness of per-rectal portal scintigraphy with Tc-99m pertechnetate for galactosemia in infants

    Energy Technology Data Exchange (ETDEWEB)

    Shiomi, Susumu; Sasaki, Nobumitsu; Ikeoka, Naoko; Kuroki, Tetsuo; Okano, Yoshiyuki; Kawabe, Joji; Ochi, Hironobu [Osaka City Univ. (Japan). Medical School

    1998-12-01

    Galactosemia discovered by newborn screening is rarely caused by enzyme deficiency. It has recently been reported that among patients without enzyme deficiency portosystemic shunting may be a cause of galactosemia in some patients. We did per-rectal portal scintigraphy in patients with such galactosemia detected during screening of newborns to examine the usefulness of this method for the diagnosis of portosystemic shunts via the inferior mesenteric vein. The subjects were eight neonates with galactosemia without enzyme deficiency detected during screening. A solution containing technetium-99m pertechnetate was instilled into the rectum, and serial scintigrams were taken while radioactivity curves for the liver and heart were recorded sequentially. The per-rectal portal shunt index was determined by calculating the ratio for counts of the liver to counts for the heart integrated for 24 seconds immediately after the appearance of the liver time-activity curve. A portosystemic shunt was detected in both of the patients with a shunt index of 30% or more, but not in the six patients with a shunt index less than 30%. The blood galactose levels of these six patients later entered the reference range. This method is noninvasive and there is little exposure to the radionuclide. It seemed to be useful for the diagnosis of portosystemic shunt in newborns with galactosemia without enzyme deficiency. (author)

  17. Comparison between biventricular cine MRI and MR flow quantification in ascending aorta and pulmonary outflow tract for the assessment of intracardial shunt volumes

    International Nuclear Information System (INIS)

    Rominger, M.B.; Kluge, A.; Bachmann, G.F.; Dinkel, H.P.

    2002-01-01

    Purpose: Comparison between biventricular volumetric measurements and flow measurements in ascending aorta (Ao) and pulmonary outflow tract (Pu) for quantification of intracardial shunts, and evaluation of the combination of biventricular cine MRI with flow measurements for the assessment of RV and LV heart failure and valvular regurgitation (VR). Material and Methods: In 24 patients, right (RV) and left (LV) ventricular volumetric and flow measurements were performed in the Ao and Pu to assess the ratio of RV stroke volume (SV) or, respectively, pulmonary SV to LV SV or, respectively, systemic aortic SV (Qp/Qs). 34 patients without echocardiographically proven shunt or VR served as control group for measurement accuracy. Left-to-right shunt ratios were calculated from RV and LV SV, Pu and Ao SV, Pu and LV SV, and RV and Ao SV. Left ventricular VR was calculated by the difference of LV SV and Ao SV, and right ventricular VR by the difference of RV SV and Pu SV. Global systolic function was evaluated by biventricular cine MRI. Results: Intracardial shunts with Qp/Qs>1,16 can be quantified by flow measurements in Ao and Pu. Using biventricular volumetric measurements in cases without VR, requires a Qp/Qs>1.21. 17 of 18 intracardiac shunts were identified on MRI, and all 8 hemodynamically significant shunts were quantitatively confirmed. The diagnosis of complete shunt closure or absent shunt was correctly made in all 6 cases RV EF reduction was found in 6 of 24 patients. LV EF reduction was also found in 6 of 24 patients. Conclusion: Flow measurements in Ao and Pu are more accurate than biventricular cine MRI for the assessment of Qp/Qs ratios. Flow measurements in Ao and Pu combined with biventricular cine MRI enables the quantification of hemodynamic significant shunts, higher grade VR and biventricular global systolic function with a single examination. (orig.) [de

  18. Shunt hybrid active power filter for harmonic mitigation: A practical ...

    Indian Academy of Sciences (India)

    shunt HAPF, APF is connected in series with PPF and the whole system is connected in parallel to the load. ... LC filter, it will force a fundamental reactive current to flow into it. ..... Since SHAPF is operating as a boost rectifier, d.c. voltage.

  19. Leakage Inductance Calculation for Planar Transformers with a Magnetic Shunt

    DEFF Research Database (Denmark)

    Jun, Zhang; Ouyang, Ziwei; Duffy, M. C.

    2013-01-01

    The magnetic shunt is generally inserted in a planar transformer to increase the leakage inductance which can be utilized as the series inductor in resonant circuits such as the LLC resonant converter. This paper presents a calculation methodology for the leakage inductance of the transformer...

  20. Embolization of nonvariceal portosystemic collaterals in transjugular intrahepatic portosystemic shunts

    International Nuclear Information System (INIS)

    Bilbao, Jose Ignacio; Arias, Mercedes; Longo, Jesus Maria; Alejandre, Pedro Luis; Betes, Maria Teresa; Elizalde, Arlette Maria

    1997-01-01

    Percutaneous embolization of large portosystemic collaterals was performed in three patients following placement of a transjugular intrahepatic portosystemic shunt in order to improve hepatopetal portal flow. Improved hepatic portal perfusion was achieved in these cases, thereby theoretically reducing the risk of chronic hepatic encephalopathy

  1. Protective effects of a wheat germ rich diet against the toxic influence of profenofos on rat tissue lipids and oxidative pentose phosphate shunt enzymes

    Directory of Open Access Journals (Sweden)

    Abdel-Rahim, G. A.

    2011-09-01

    Full Text Available The effects of technical and formulated forms of profenofos on the metabolic lipid fractions of the liver, brain and kidneys as well as the activity of glucose-6-phosphate dehydrogenase (G6PD and 6-phosphogluconate dehydrogenase (6PGD, which consider lipid related enzymes, were studied. The two forms of profenofos were given separately either orally or by dermal at doses of 1/20 LD50 for 3 months (one dose every 48 h. Total lipids and lipid fractions (cholesterol, triglycerides and phospholipid contents decreased in the three studied organ tissues either in technical or formulated profenofos-induced rats compared with normal control animals. The highest effect was observed in the case of orally formulated profenofo induction, and the lowest was detected for the dermal technical one. The same trend was found in the activities of G6PD and 6PGD associated with lipid metabolism in the liver, brain and kidney tissues under the same conditions. On other hand, the treatment of profenofos-induced animals by feeding a wheat germ rich diet (as antioxidant agent produced significant improvements in both lipid fraction content and enzyme activity. In addition, the effects of the wheat germ rich diet (α-tocopherol rich source readjusted and improved the disturbed metabolic fractions of the lipid profiles in the profenofos-induced rats as well as their related enzyme activities (G6PD and 6PGD: oxidative pentose phosphate shunt.

    El efecto de formas técnicas o formuladas de profenofós en la fracción lipídica metabólica de hígado, cerebro y riñones así como la actividad de la glucosa-6-fosfato deshidrogenasa (G6PD y 6-fosfogluconato deshidrogenasa (6PGD, que son consideradas enzimas relacionadas con los lípidos, fueron estudiadas. Ambas formas de profenofós fueron suministradas separadamente tanto por vía oral como cutánea a una dosis de 1/20 LD50 durante 3 meses (una dosis cada 48 horas. Los lípidos totales y

  2. Global robust stability for shunting inhibitory CNNs with delays.

    Science.gov (United States)

    Wang, Lingna; Lin, Yiping

    2004-08-01

    In this paper, the problem of global robust stability for shunting inhibitory cellular neural networks (SICNNs) is studied. A sufficient condition guaranteeing the network's global robust stability is established. The result can easily be used to verify globally robust stable networks. An example is given to illustrate that the conditions of our results are feasible.

  3. Shunt Surgery, Right Heart Catheterization, and Vascular Morphometry in a Rat Model for Flow-induced Pulmonary Arterial Hypertension

    NARCIS (Netherlands)

    van der Feen, Diederik E.; Weij, Michel; Smit-van Oosten, Annemieke; Jorna, Lysanne M.; Hagdorn, Quint A. J.; Bartelds, Beatrijs; Berger, Rolf M. F.

    2017-01-01

    In this protocol, PAH is induced by combining a 60 mg/kg monocrotalin (MCT) injection with increased pulmonary blood flow through an aorto-caval shunt (MCT+Flow). The shunt is created by inserting an 18-G needle from the abdominal aorta into the adjacent caval vein. Increased pulmonary flow has been

  4. Harmonic Resonance in Power Transmission Systems due to the Addition of Shunt Capacitors

    Science.gov (United States)

    Patil, Hardik U.

    Shunt capacitors are often added in transmission networks at suitable locations to improve the voltage profile. In this thesis, the transmission system in Arizona is considered as a test bed. Many shunt capacitors already exist in the Arizona transmission system and more are planned to be added. Addition of these shunt capacitors may create resonance conditions in response to harmonic voltages and currents. Such resonance, if it occurs, may create problematic issues in the system. It is main objective of this thesis to identify potential problematic effects that could occur after placing new shunt capacitors at selected buses in the Arizona network. Part of the objective is to create a systematic plan for avoidance of resonance issues. For this study, a method of capacitance scan is proposed. The bus admittance matrix is used as a model of the networked transmission system. The calculations on the admittance matrix were done using Matlab. The test bed is the actual transmission system in Arizona; however, for proprietary reasons, bus names are masked in the thesis copy intended for the public domain. The admittance matrix was obtained from data using the PowerWorld Simulator after equivalencing the 2016 summer peak load (planning case). The full Western Electricity Coordinating Council (WECC) system data were used. The equivalencing procedure retains only the Arizona portion of the WECC. The capacitor scan results for single capacitor placement and multiple capacitor placement cases are presented. Problematic cases are identified in the form of 'forbidden response. The harmonic voltage impact of known sources of harmonics, mainly large scale HVDC sources, is also presented. Specific key results for the study indicated include: (1) The forbidden zones obtained as per the IEEE 519 standard indicates the bus 10 to be the most problematic bus. (2) The forbidden zones also indicate that switching values for the switched shunt capacitor (if used) at bus 3 should be

  5. [Results of the mesoportal bypass (Rex shunt) in the treatment of idiopathic extrahepatic portal vein obstruction in children].

    Science.gov (United States)

    Domínguez Amillo, E; De la Torre Ramos, C; Andrés Moreno, A; Encinas Hernández, J L; Hernández Oliveros, F; López Santamaría, M

    2017-01-25

    Extrahepatic portal vein obstruction (EPVO) is the principal cause of portal hypertension in children. The objective of this study was to analyze the capacity of the surgical technique that creates a mesoportal shunt to treat changes caused by EPVO. Retrospective review of patients with idiopathic EPVO who underwent a mesoportal shunt and analysis of the changes in the number of leucocytes, platelets, prothrombin time and spleen size one year after the surgery. Twelve patients underwent surgery, out of which 10 had prior leukopenia, 11 thrombopenia, 9 longer prothrombin times and all had hypersplenism. One patient suffered a postoperative shunt thrombosis, was reoperated and underwent a change in the operative technique. The remaining patients (92%) have functioning shunts 4.3 ± 2.5 years after surgery, and none have suffered any episode of gastrointestinal bleeding. One year after surgery, there were significant changes in the number of platelets, prothrombin time and spleen size, with no significant changes in the number of leukocytes. However, the number of patients who went from a leukopenic to a normal state was significant, as happened with changes in prothrombin time. Mesoportal Rex shunt improves some of the disorders caused by portal hypertension in children suffering EPVO, with a high rate of surgical success. This technique should be of first choice in these patients.

  6. Poly(ethyl glyoxylate)-Poly(ethylene oxide) Nanoparticles: Stimuli-Responsive Drug Release via End-to-End Polyglyoxylate Depolymerization.

    Science.gov (United States)

    Fan, Bo; Gillies, Elizabeth R

    2017-08-07

    The ability to disrupt polymer assemblies in response to specific stimuli provides the potential to release drugs selectively at certain sites or conditions in vivo. However, most stimuli-responsive delivery systems require many stimuli-initiated events to release drugs. "Self-immolative polymers" offer the potential to provide amplified responses to stimuli as they undergo complete end-to-end depolymerization following the cleavage of a single end-cap. Herein, linker end-caps were developed to conjugate self-immolative poly(ethyl glyoxylate) (PEtG) with poly(ethylene oxide) (PEO) to form amphiphilic block copolymers. These copolymers were self-assembled to form nanoparticles in aqueous solution. Cleavage of the linker end-caps were triggered by a thiol reducing agent, UV light, H 2 O 2 , and combinations of these stimuli, resulting in nanoparticle disintegration. Low stimuli concentrations were effective in rapidly disrupting the nanoparticles. Nile red, doxorubin, and curcumin were encapsulated into the nanoparticles and were selectively released upon application of the appropriate stimulus. The ability to tune the stimuli-responsiveness simply by changing the linker end-cap makes this new platform highly attractive for applications in drug delivery.

  7. Reversal of Transjugular Intrahepatic Portosystemic Shunt (TIPS)-Induced Hepatic Encephalopathy Using a Strictured Self-Expanding Covered Stent

    International Nuclear Information System (INIS)

    Cox, Mitchell W.; Soltes, George D.; Lin, Peter H.; Bush, Ruth L.; Lumsden, Alan B.

    2003-01-01

    Hepatic encephalopathy is a known complication following percutaneous transjugular intrahepatic portosystemic shunt (TIPS) placement. We describe herein a simple and effective strategy of TIPS revision by creating an intraluminal stricture within a self-expanding covered stent, which is deployed in the portosystemic shunt to reduce the TIPS blood flow. This technique was successful in reversing a TIPS-induced hepatic encephalopathy in our patient

  8. Incorporation of distributed generation and shunt capacitor in radial distribution system for techno-economic benefits

    Directory of Open Access Journals (Sweden)

    Mukul Dixit

    2017-04-01

    The various costs such as purchase active power from grid, DG installation, capacitor installation, DG Operation and Maintenance (O&M are evaluated at two different load scenarios. In addition to that, technical and economical analyses are examined for various combinations of DGs and shunt capacitors. The proposed methodology is successfully demonstrated on 33-bus and 85-bus radial networks and the obtained numerical outcomes validate the suitability, importance and effectiveness to identify locations as well as sizes of DGs and shunt capacitors.

  9. Comparison of Acute Thrombogenicity for Magnesium versus Stainless Steel Stents in a Porcine Arteriovenous Shunt Model.

    Science.gov (United States)

    Lipinski, Michael J; Acampado, Eduardo; Cheng, Qi; Adams, Lila; Torii, Sho; Gai, Jiaxiang; Torguson, Rebecca; Hellinga, David G; Joner, Michael; Harder, Claus; Zumstein, Philine; Finn, Aloke V; Kolodgie, Frank D; Virmani, Renu; Waksman, Ron

    2018-05-08

    Aims The aetiology for reduced thrombogenicity of the Magmaris resorbable magnesium scaffold (RMS) when compared with the Absorb bioresorbable vascular scaffold remains unclear. We therefore investigated whether the Magmaris RMS has platelet-repelling properties by comparing its acute thrombogenicity with an equivalent stainless steel stent in an arteriovenous shunt model. Methods and Results An ex vivo porcine carotid jugular arteriovenous shunt was established and connected to Sylgard tubing containing the Magmaris RMS with sirolimus-eluting PLLA coating and an equivalent 316L stainless steel stent with sirolimus-eluting PLLA coating. Six shunts (2 shunt runs per pig) were run comparing the 2 scaffolds (n=9) in alternating order. Nested generalised linear mixed models were employed to compare variables between scaffold groups. Confocal fluorescent microscopy costaining CD61/CD42b demonstrated that the 316L equivalent stent had significantly greater platelet coverage of the total scaffold compared with Magmaris (5.8% vs. 2.8%, Rate ratio 2.21 [1.41, 3.47], p=0.012). Scanning electron microscopy demonstrated significantly greater thrombus deposition on the 316L equivalent stent as a percentage of the total scaffold compared with Magmaris (8.0% vs. 5.3%, p=0.009). Magmaris also had significantly less CD14 positive monocyte deposition and a trend toward less PM-1 positive neutrophil compared with the 316L equivalent stent. Conclusion Despite having identical scaffold characteristics regarding geometrical design, Magmaris had significantly less thrombogenicity and inflammatory cell deposition compared with the equivalent 316L stainless steel stent in a porcine arteriovenous shunt model. These data suggest resorbable magnesium scaffolds may have inherent properties that reduce adhesion of platelets and inflammatory cells.

  10. [Pleuro-peritoneal shunt in a patient with intractable pleural effusion after cardiac surgery].

    Science.gov (United States)

    Tsuji, Maiko; Yamazaki, Takenori

    2014-10-01

    A 45-year-old man experienced dyspnea on effort and was hospitalized due to severe mitral valve regurgitation and atrial fibrillation. He also had alcoholic cirrhosis. After he was stabilized, mitral valve plasty and Maze procedure were performed. The postoperative clinical course was satisfactory. During the follow-up period, he began to suffer from persistent left pleural effusion, which amounted to about 2,500 to 3,000 ml, and required intercostal tube drainage weekly. Therefore a pleuro-peritoneal shunt was implanted. The pleural effusion decreased, and he obtained significant relief from dyspnea. After one year, we confirmed that pleural effusion had not reoccurred, and removed the pleuro-peritoneal shunt.

  11. Improving Properties of a Novel β-Galactosidase from Lactobacillus plantarum by Covalent Immobilization

    Directory of Open Access Journals (Sweden)

    Rocio Benavente

    2015-04-01

    Full Text Available A novel β-galactosidase from Lactobacillus plantarum (LPG was over-expressed in E. coli and purified via a single chromatographic step by using lowly activated IMAC (immobilized metal for affinity chromatography supports. The pure enzyme exhibited a high hydrolytic activity of 491 IU/mL towards o-nitrophenyl β-d-galactopyranoside. This value was conserved in the presence of different divalent cations and was quite resistant to the inhibition effects of different carbohydrates. The pure multimeric enzyme was stabilized by multipoint and multisubunit covalent attachment on glyoxyl-agarose. The glyoxyl-LPG immobilized preparation was over 20-fold more stable than the soluble enzyme or the one-point CNBr-LPG immobilized preparation at 50 °C. This β-galactosidase was successfully used in the hydrolysis of lactose and lactulose and formation of different oligosaccharides was detected. High production of galacto-oligosaccharides (35% and oligosaccharides derived from lactulose (30% was found and, for the first time, a new oligosaccharide derived from lactulose, tentatively identified as 3'-galactosyl lactulose, has been described.

  12. Amenorrhea after Endoscopic Third Ventriculostomy for a Failed Shunt in Spina Bifida: Case Report and Review of the Literature.

    Science.gov (United States)

    Giordano, Flavio; Spacca, Barbara; Danti, Alfredo; Taverna, Maria; Losi, Stefania; Stagi, Stefano; Genitori, Lorenzo

    2016-01-01

    Secondary endoscopic third ventriculostomy (ETV) for the management of shunt failure may be efficacious, though it may be followed by more frequent complications (including endocrinological impairment, e.g., amenorrhea) compared to primary ETV. These complications are usually underreported in the literature. We report a case of secondary amenorrhea after ETV for the management of shunt failure in a young woman with hydrocephalus associated with myelomeningocele. A 25-year-old woman affected by hydrocephalus and myelomeningocele was admitted for secondary ETV for the management of shunt failure. The endoscopic procedure was preferred over shunt revision based on good results of secondary ETV, especially in patients with hydrocephalus associated with Chiari II malformation and spina bifida. Despite the surgery being uneventful, the patient had early (postoperative seizure) and late (secondary amenorrhea) complications. In the early postoperative period, she received external ventricular drainage followed by VP shunt reimplantation 2 weeks later. There was no neurological morbidity, but 1 month after the ETV she reported secondary amenorrhea and weight gain. Laboratory investigations ruled out hyperprolactinemia, which had been treated with cabergoline administration with no efficacy since the patient was still without regular periods 1 year later. ETV may be followed by endocrinological complications like amenorrhea that are rarely reported. © 2015 S. Karger AG, Basel.

  13. The impact of the type of operation on the parameters of a shunting diesel locomotive with hybrid power plant

    Directory of Open Access Journals (Sweden)

    Falendysh Anatoliy

    2017-01-01

    Full Text Available In designing a traction vehicle it is necessary to take into account the type of field operation it is meant for. It was found out that during shunting operation a ChME3 diesel locomotive is in idling mode for almost half of its general running time. That is why, the introduction of a less powerful engine along with an energy storage device for shunting operations at a shunting diesel locomotive is appropriate. The calculations were made using a modernized shunting diesel locomotive ChME3 with hybrid transmission of power as an example. The dependences of the general running time of a diesel locomotive on the position of the engine driver controller under performing shunting, transportation and hump operation were given in percentages. For every operation mode there was calculated the optimum power of a diesel-generator plant and the optimum energy capacity of an energy storage system taking into account the above-mentioned dependences. It was found out that due to the introduction of a hybrid drive for the section discussed above and the corresponding mass of a train the aggregate fuel consumption will be reduced by 25% and the efficiency of travel will increase by one third.

  14. A plasma polymerization technique to overcome cerebrospinal fluid shunt infections

    Czech Academy of Sciences Publication Activity Database

    Çökeliler, D.; Caner, H.; Zemek, Josef; Choukourov, A.; Biederman, H.; Mutlu, M.

    2007-01-01

    Roč. 2, č. 1 (2007), s. 39-47 ISSN 1748-6041 Grant - others:TUBITAK(TR) MISAG-COST 527 Institutional research plan: CEZ:AV0Z10100521 Keywords : shunt infections * cerebrospinal * PP HEMA * biomaterials Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 0.787, year: 2007

  15. Aberrant hepatic lipid storage and metabolism in canine portosystemic shunts

    NARCIS (Netherlands)

    Van Den Bossche, Lindsay; Schoonenberg, Vivien A.C.; Burgener, Iwan A.; Penning, Louis C.; Schrall, Ingrid M.; Kruitwagen, Hedwig S.; Van Wolferen, Monique E.; Grinwis, Guy C.M.; Kummeling, Anne; Rothuizen, Jan; Van Velzen, Jeroen F.; Stathonikos, Nikolas; Molenaar, Martijn R.; Helms, Bernd J.; Brouwers, Jos F.H.M.; Spee, Bart; Van Steenbeek, Frank G.

    2017-01-01

    Non-alcoholic fatty liver disease (NAFLD) is a poorly understood multifactorial pandemic disorder. One of the hallmarks of NAFLD, hepatic steatosis, is a common feature in canine congenital portosystemic shunts. The aim of this study was to gain detailed insight into the pathogenesis of steatosis in

  16. A Case of Shunting Postoperative Patent Foramen Ovale Under Mechanical Ventilation Controlled by Different Ventilator Settings.

    Science.gov (United States)

    Pragliola, Claudio; Di Michele, Sara; Galzerano, Domenico

    2017-06-07

    A 56-year old male with ischemic heart disease and an unremarkable preoperative echocardiogram underwent surgical coronary revascularization. An intraoperative post pump trans-esophageal echocardiogram (TOE) performed while the patient was being ventilated at a positive end expiratory pressure (PEEP) of 8 cm H 2 O demonstrated a right to left interatrial shunt across a patent foramen ovale (PFO). Whereas oxygen saturation was normal, a reduction of the PEEP to 3 cm H 2 O led to the complete resolution of the shunt with no change in arterial blood gases. Attempts to increase the PEEP level above 3 mmHg resulted in recurrence of the interatrial shunt. The remaining of the TEE was unremarkable. Mechanical ventilation, particularly with PEEP, causes an increase in intrathoracic pressure. The resulting rise in right atrial pressure, mostly during inspiration, may unveil and pop open an unrecognized PFO, thus provoking a right to left shunt across a seemingly intact interatrial septum. This phenomenon increases the risk of paradoxical embolism and can lead to hypoxemia. The immediate management would be to adjust the ventilatory settings to a lower PEEP level. A routine search for a PFO should be performed in ventilated patients who undergo a TEE.

  17. A case of shunting postoperative patent foramen ovale under mechanical ventilation controlled by different ventilator settings

    Directory of Open Access Journals (Sweden)

    Claudio Pragliola

    2017-08-01

    Full Text Available A 56-year old male with ischemic heart disease and an unremarkable preoperative echocardiogram underwent surgical coronary revascularization. An intraoperative post pump trans-esophageal echocardiogram (TOE performed while the patient was being ventilated at a positive end expiratory pressure (PEEP of 8 cm H2O demonstrated a right to left interatrial shunt across a patent foramen ovale (PFO. Whereas oxygen saturation was normal, a reduction of the PEEP to 3 cm H2O led to the complete resolution of the shunt with no change in arterial blood gases. Attempts to increase the PEEP level above 3 mmHg resulted in recurrence of the interatrial shunt. The remaining of the TEE was unremarkable. Mechanical ventilation, particularly with PEEP, causes an increase in intrathoracic pressure. The resulting rise in right atrial pressure, mostly during inspiration, may unveil and pop open an unrecognized PFO, thus provoking a right to left shunt across a seemingly intact interatrial septum. This phenomenon increases the risk of paradoxical embolism and can lead to hypoxemia. The immediate management would be to adjust the ventilatory settings to a lower PEEP level. A routine search for a PFO should be performed in ventilated patients who undergo a TEE.

  18. Thoraco-amniotic shunting for fetal pleural effusion--a case series.

    LENUS (Irish Health Repository)

    Walsh, J

    2011-11-15

    Fetal pleural effusion is a rare occurrence, with an incidence of 1 per 10-15,000 pregnancies. The prognosis is related to the underlying cause and is often poor. There is increasing evidence that in utero therapy with thoraco-amniotic shunting improves prognosis by allowing lung expansion thereby preventing hydrops and pulmonary hypoplasia. This is a review of all cases of fetal pleural effusion managed over an eight year period the National Maternity Hospital Dublin. Over the nine year period there were 21 cases of fetal pleural effusion giving an overall incidence of 1 per 9281 deliveries. Of these, 15 underwent thoraco-amniotic shunting. There were associated anomalies diagnosed in 5 (33%) of cases. The overall survival in our cohort was 53%. The presence of hydrops was a poor prognostic factor, with survival in cases with hydrops of 33% (3\\/9) compared to 83% (5\\/6) in those cases without associated hydrops.

  19. Portosystemic shunting in portal hypertension: evaluation with portal scintigraphy with transrectally administered I-123 IMP

    International Nuclear Information System (INIS)

    Kashiwagi, T.; Azuma, M.; Ikawa, T.; Takehara, T.; Matsuda, H.; Yoshioka, H.; Mitsutani, N.; Koizumi, T.; Kimura, K.

    1988-01-01

    Portosystemic shunting was evaluated with rectal administration of iodine-123 iodoamphetamine (IMP) in seven patients without liver disease and 53 patients with liver cirrhosis. IMP (2-3 mCi [74-111 MBq]) was administered to the rectum through a catheter. Images of the chest and abdomen were obtained for up to 60 minutes with a scintillation camera interfaced with a computer. In all patients, images of the liver and/or lungs were observed within 5-10 minutes and became clear with time. In patients without liver disease, only liver images could be obtained, whereas the lung was visualized with or without the liver in all patients with liver cirrhosis. The portosystemic shunt index was calculated by dividing counts of lungs by counts of liver and lung. These values were significantly higher in liver cirrhosis, especially in the decompensated stage. Transrectal portal scintigraphy with IMP appears to be a useful method for noninvasive and quantitative evaluation of portosystemic shunting in portal hypertension

  20. Predictors of shunt-dependent hydrocephalus following aneurysmal subarachnoid hemorrhage: a pilot study in a single Egyptian institute.

    Science.gov (United States)

    Aboul-Ela, Hashem M; Salah El-Din, Ahmed M; Zaater, Ahmed A; Shehab, Mohamed; El Shahawy, Ossama A

    2018-01-01

    Acute hydrocephalus can cause neurological deterioration after aneurysmal subarachnoid hemorrhage (aSAH). Predicting which patient would require shunting is challenging. This prospective study was conducted upon twenty patients who suffered acute hydrocephalus due to subarachnoid hemorrhage of ruptured aneurysms. Surgical or non-surgical management of hydrocephalus was conducted. Glasgow Coma scale (GCS) was assessed, and hydrocephalus was graded by bicaudate index. Fisher grade was determined from CT scan. Aneurysm site was determined by conventional or CT angiography. Either surgical clipping or endovascular coiling of aneurysms was performed. Initially, 3 (15%) patients had emergency CSF diversion on admission due to poor GCS on arrival. Initially, the remaining 17 patients were managed conservatively. Five patients did not require any intervention. Twelve patients had external ventricular drainage placement, 4 were weaned, and 8 failed weaning. High bicaudate index (> 0.2) correlated with shunting. Aneurysm site correlated well with shunting (ACoA or PCoA). Patients with fair GCS can be managed conservatively. Any deterioration warrants shifting to CSF diversion. Higher bicaudate index will usually need CSF diversion. The value of Fisher carries no significant value. Aneurysm location (ACoA or PCoA) correlates with an increased incidence of ventriculoperitoneal shunt placement.

  1. Quantitative measurement of Y90 brehmmstrahlung images after of Y90 Sir-Spheres implantation to assess lung shunting

    International Nuclear Information System (INIS)

    Forwood, Nicholas J.; Pocock, Nicholas; Shin, Jane; Young, Andy M; Szeto, Edwin R.

    2009-01-01

    Full text: Background: In clinical practice the dose of Y 9 0 Sir-Spheres is calculated using a pre injection of Tc 9 9 m MAA. There is however a potential difference due to the different properties of Tc 9 9 m MAA and Y 9 0 Sir-Spheres. We assessed the concordance of lung shunting of Y 9 0 Sir-Spheres estimated using Y 9 0 Bremsstrahlung imaging, compared to shunting assessed using Tc 9 9 m MAA. Methods: 15 Patients were evaluated using 150-200 MBq of Tc 9 9 m MAA injected into the hepatic artery under angiographic guidance. Whole body images were acquired using a LEAP collimator (window of 140 kEv+/-10%). The patients were subsequently treated with Y 9 0 Sir-Spheres. After microspheres injection, whole body brehmsstrahlung images were acquired using a medium energy collimator (window settings of 75 kEv +/- 20%). Tc 9 9 m MAA images were paired with their corresponding bremsstrahlung image and lung shunting in the stu ides calculated simultaneously. Each paired dataset was analyzed by 5 operators. Results: The mean lung shunting for Tc 9 9 m MAA acquisition was 3.32% (SD 2.03) which was significantly lower than the lung shunting using the Y 9 0 acquisitions: mean 16.19% (SD of 6.43). The Pearson coefficient was r = 0.62 (p 9 0 Sir-Spheres bremsstrahlung imaging is higher than that calculated by Tc 9 9 m MAA imaging. The relationship is not sufficiently strong to use bremsstahlung imaging to retrospectively quantify the lung-to-liver shunting as indicated using Tc 9 9 M AA. Further studies are underway to assess the reliability of Tc 9 9 m MAA lung uptake calculations in determining the dose of Y 9 0 Sir-Spheres.

  2. Hepatic gene expression and plasma albumin concentration related to outcome after attenuation of a congenital portosystemic shunt in dogs

    NARCIS (Netherlands)

    Kummeling, A.; Penning, L.C.; Rothuizen, J.; Brinkhof, B.; Weber, M.F.; van Sluijs, F.J.

    2012-01-01

    Abstract In dogs with a congenital portosystemic shunt (CPSS), the outcome after CPSS attenuation is difficult to predict but is most likely related to hepatic and vascular proliferation that follows the attenuation. The aim of this study was to evaluate the prognostic value of shunt localization

  3. On-line process analysis innovation: DiComp (tm) shunting dielectric sensor technology

    Science.gov (United States)

    Davis, Craig R.; Waldman, Frank A.

    1993-01-01

    The DiComp Shunting Dielectric Sensor (SDS) is a new patent-pending technology developed under the Small Business Innovation Research Program (SBIR) for NASA's Kennedy Space Center. The incorporation of a shunt electrode into a conventional fringing field dielectric sensor makes the SDS uniquely sensitive to changes in material dielectric properties in the KHz to MHz range which were previously detectable only at GHz measurement frequencies. The initial NASA application of the SDS for Nutrient Delivery Control has demonstrated SDS capabilities for thickness and concentration measurement of Hoagland nutrient solutions. The commercial introduction of DiComp SDS technology for concentration and percent solids measurements in dispersions, emulsions and solutions represents a new technology for process measurements for liquids in a variety of industries.

  4. Percutaneous transluminal angioplasty of an occluded surgical splenorenal shunt in a 4-year-old child after liver transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Yussim, Ethan; Belenky, Alexander; Atar, Eli [Department of Diagnostic Radiology, Rabin Medical Center, Vascular and Interventional Radiology Unit, Petah Tikva (Israel); Shapiro, Rivka [Schneider Children' s Medical Center, Institute of Pediatric Gastroenterology and Nutrition, Petah Tikva (Israel); Mor, Eytan [Rabin Medical Center, Department of Organ Transplantation, Petah Tikva (Israel)

    2005-07-01

    Percutaneous transluminal angioplasty is increasingly used in children. We present a case of successful balloon angioplasty of an occluded surgical splenorenal shunt in a 4-year-old child who underwent liver transplantation because of biliary atresia. Percutaneous reopening of the shunt is a relatively safe procedure that may spare patients of surgical intervention. (orig.)

  5. Percutaneous transluminal angioplasty of an occluded surgical splenorenal shunt in a 4-year-old child after liver transplantation

    International Nuclear Information System (INIS)

    Yussim, Ethan; Belenky, Alexander; Atar, Eli; Shapiro, Rivka; Mor, Eytan

    2005-01-01

    Percutaneous transluminal angioplasty is increasingly used in children. We present a case of successful balloon angioplasty of an occluded surgical splenorenal shunt in a 4-year-old child who underwent liver transplantation because of biliary atresia. Percutaneous reopening of the shunt is a relatively safe procedure that may spare patients of surgical intervention. (orig.)

  6. Adaptation of red cell enzymes and intermediates in metabolic disorders.

    Science.gov (United States)

    Goebel, K M; Goebel, F D; Neitzert, A; Hausmann, L; Schneider, J

    1975-01-01

    The metabolic activity of the red cell glycolytic pathway hexose monophosphate shunt (HMP) with dependent glutathione system was studied in patients with hyperthyroidism (n = 10), hyperlipoproteinemia (n = 16), hypoglycemia (n = 25) and hyperglycemia (n = 23). In uncontrolled diabetics and patients with hyperthyroidism the mean value of glucose phosphate isomerase (GPI), glucose-6-phosphate dehydrogenase (G-6-PD), glutathione reductase (GR) was increased, whereas these enzyme activities were reduced in patients with hypoglycemia. Apart from a few values of hexokinase (HK) which were lower than normal the results in hyperlipoproteinemia patients remained essentially unchanged, including the intermediates such as 2,3-diphosphoglycerate (2,3-DPG), adenosine triphosphate (ATP) and reduced glutathione (GSH). While increased rates of 2,3-DPG and ATP in hypoglycemia patients were obtained, these substrates were markedly reduced in diabetics.

  7. New biotechnological perspectives of a NADH oxidase variant from Thermus thermophilus HB27 as NAD+-recycling enzyme

    Directory of Open Access Journals (Sweden)

    Rocha-Martín Javier

    2011-11-01

    Full Text Available Abstract Background The number of biotransformations that use nicotinamide recycling systems is exponentially growing. For this reason one of the current challenges in biocatalysis is to develop and optimize more simple and efficient cofactor recycling systems. One promising approach to regenerate NAD+ pools is the use of NADH-oxidases that reduce oxygen to hydrogen peroxide while oxidizing NADH to NAD+. This class of enzymes may be applied to asymmetric reduction of prochiral substrates in order to obtain enantiopure compounds. Results The NADH-oxidase (NOX presented here is a flavoenzyme which needs exogenous FAD or FMN to reach its maximum velocity. Interestingly, this enzyme is 6-fold hyperactivated by incubation at high temperatures (80°C under limiting concentrations of flavin cofactor, a change that remains stable even at low temperatures (37°C. The hyperactivated form presented a high specific activity (37.5 U/mg at low temperatures despite isolation from a thermophile source. Immobilization of NOX onto agarose activated with glyoxyl groups yielded the most stable enzyme preparation (6-fold more stable than the hyperactivated soluble enzyme. The immobilized derivative was able to be reactivated under physiological conditions after inactivation by high solvent concentrations. The inactivation/reactivation cycle could be repeated at least three times, recovering full NOX activity in all cases after the reactivation step. This immobilized catalyst is presented as a recycling partner for a thermophile alcohol dehydrogenase in order to perform the kinetic resolution secondary alcohols. Conclusion We have designed, developed and characterized a heterogeneous and robust biocatalyst which has been used as recycling partner in the kinetic resolution of rac-1-phenylethanol. The high stability along with its capability to be reactivated makes this biocatalyst highly re-useable for cofactor recycling in redox biotransformations.

  8. Use of mathematic modeling to compare and predict hemodynamic effects of the modified Blalock-Taussig and right ventricle-pulmonary artery shunts for hypoplastic left heart syndrome.

    Science.gov (United States)

    Bove, Edward L; Migliavacca, Francesco; de Leval, Marc R; Balossino, Rossella; Pennati, Giancarlo; Lloyd, Thomas R; Khambadkone, Sachin; Hsia, Tain-Yen; Dubini, Gabriele

    2008-08-01

    Stage one reconstruction (Norwood operation) for hypoplastic left heart syndrome can be performed with either a modified Blalock-Taussig shunt or a right ventricle-pulmonary artery shunt. Both methods have certain inherent characteristics. It is postulated that mathematic modeling could help elucidate these differences. Three-dimensional computer models of the Blalock-Taussig shunt and right ventricle-pulmonary artery shunt modifications of the Norwood operation were developed by using the finite volume method. Conduits of 3, 3.5, and 4 mm were used in the Blalock-Taussig shunt model, whereas conduits of 4, 5, and 6 mm were used in the right ventricle-pulmonary artery shunt model. The hydraulic nets (lumped resistances, compliances, inertances, and elastances) were identical in the 2 models. A multiscale approach was adopted to couple the 3-dimensional models with the circulation net. Computer simulations were compared with postoperative catheterization data. Good correlation was found between predicted and observed data. For the right ventricle-pulmonary artery shunt modification, there was higher aortic diastolic pressure, decreased pulmonary artery pressure, lower Qp/Qs ratio, and higher coronary perfusion pressure. Mathematic modeling predicted minimal regurgitant flow in the right ventricle-pulmonary artery shunt model, which correlated with postoperative Doppler measurements. The right ventricle-pulmonary artery shunt demonstrated lower stroke work and a higher mechanical efficiency (stroke work/total mechanical energy). The close correlation between predicted and observed data supports the use of mathematic modeling in the design and assessment of surgical procedures. The potentially damaging effects of a systemic ventriculotomy in the right ventricle-pulmonary artery shunt modification of the Norwood operation have not been analyzed.

  9. Shunt hybrid active power filter for harmonic mitigation: A practical ...

    Indian Academy of Sciences (India)

    2016-08-26

    Aug 26, 2016 ... The increasing importance of Power Quality problems has been responsible for several improvements in Active Power Filter (APF) typologies in the last decade. The increased cost and switching losses make a pure shunt APF economically impractical for high power applications. In higher power levels ...

  10. Percutaneous Mesocaval Shunt Creation in a Patient with Chronic Portal and Superior Mesenteric Vein Thrombosis

    International Nuclear Information System (INIS)

    Bercu, Zachary L.; Sheth, Sachin B.; Noor, Amir; Lookstein, Robert A.; Fischman, Aaron M.; Nowakowski, F. Scott; Kim, Edward; Patel, Rahul S.

    2015-01-01

    The creation of a transjugular intrahepatic portosystemic shunt (TIPS) is a critical procedure for the treatment of recurrent variceal bleeding and refractory ascites in the setting of portal hypertension. Chronic portal vein thrombosis remains a relative contraindication to conventional TIPS and options are limited in this scenario. Presented is a novel technique for management of refractory ascites in a patient with hepatitis C cirrhosis and chronic portal and superior mesenteric vein thrombosis secondary to schistosomiasis and lupus anticoagulant utilizing fluoroscopically guided percutaneous mesocaval shunt creation

  11. Percutaneous Mesocaval Shunt Creation in a Patient with Chronic Portal and Superior Mesenteric Vein Thrombosis

    Energy Technology Data Exchange (ETDEWEB)

    Bercu, Zachary L., E-mail: zachary.bercu@mountsinai.org; Sheth, Sachin B., E-mail: sachinsheth@gmail.com [Icahn School of Medicine at Mount Sinai, Division of Interventional Radiology (United States); Noor, Amir, E-mail: amir.noor@gmail.com [The George Washington University School of Medicine and Health Sciences (United States); Lookstein, Robert A., E-mail: robert.lookstein@mountsinai.org; Fischman, Aaron M., E-mail: aaron.fischman@mountsinai.org; Nowakowski, F. Scott, E-mail: scott.nowakowski@mountsinai.org; Kim, Edward, E-mail: edward.kim@mountsinai.org; Patel, Rahul S., E-mail: rahul.patel@mountsinai.org [Icahn School of Medicine at Mount Sinai, Division of Interventional Radiology (United States)

    2015-10-15

    The creation of a transjugular intrahepatic portosystemic shunt (TIPS) is a critical procedure for the treatment of recurrent variceal bleeding and refractory ascites in the setting of portal hypertension. Chronic portal vein thrombosis remains a relative contraindication to conventional TIPS and options are limited in this scenario. Presented is a novel technique for management of refractory ascites in a patient with hepatitis C cirrhosis and chronic portal and superior mesenteric vein thrombosis secondary to schistosomiasis and lupus anticoagulant utilizing fluoroscopically guided percutaneous mesocaval shunt creation.

  12. Case of right atrial myxoma with right to left shunt

    Energy Technology Data Exchange (ETDEWEB)

    Nakai, Kenji; Suzuki, Tomoyuki; Ohzeki, Tetsuro (Iwate Medical Coll., Morioka (Japan). School of Medicine)

    1982-12-01

    A case of 49-year-old woman with right atrial myxoma resulting to right to left shunt, diagnosed by cardiac pool isotope image, was reported. She was admitted to our clinic because of progressive shortness of breath. At admission lip cyanosis was noted. Laboratory data included polycythemia, low O/sub 2/ saturation (89%) and high erythrocyte sedimentation rate (65 mm/1 h). Chest x-p showed slight right atrial enlargement, but no pulmonary congestion. The electrocardiogram showed sinus regular rhythm with biphasic p wave in leads II, III, aVf. Although 1st heart sound at the apex was splited, no heart murmur was heard. In usual echocardiographic approach, no abnormal echogram was obtained in the right ventricular region. Lung perfusion scintiscan with Tc-99 m-MAA showed visualization of thyroid gland and kidney, which suggested intracardiac right-to-left shunt. Cardiac pool image with Tc-99m-HSA revealed large photo-deficient area in the right atrium and early visualization of aortic arch. Computor tomography showed large round low density region 8 x 7 cm in size. Based on their findings, this patient was diagnosed as right atrial tumor. At operation a large tumor (diameter 8 x 7 x 7 cm, weight 160g) filled the lower part of the right atrium and was adherent to the anterolateral wall in the right atrium. As a cause of R-L shunt, streched foramen ovale (5 x 10 mm) was found. Tumor histology was typical of atrial myxoma. Post-operative gated cardiac isotope image showed no evidence of residual atrial tumor. Cardiac blood pool isotope imaging was a method for the noninvasive detection and assessment of right atrial myxoma.

  13. Pathway confirmation and flux analysis of central metabolicpathways in Desulfovibrio vulgaris Hildenborough using gaschromatography-mass spectrometry and fourier transform-ion cyclotronresonance mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Yinjie; Pingitore, Francesco; Mukhopadhyay, Aindrila; Phan,Richard; Hazen, Terry C.; Keasling, Jay D.

    2006-07-11

    It has been proposed that during growth under anaerobic oroxygen-limited conditions Shewanella oneidensis MR-1 uses theserine-isocitrate lyase pathway common to many methylotrophic anaerobes,in which formaldehyde produced from pyruvate is condensed with glycine toform serine. The serine is then transformed through hydroxypyruvate andglycerate to enter central metabolism at phosphoglycerate. To examine itsuse of the serine-isocitrate lyase pathway under anaerobic conditions, wegrew S. oneidensis MR-1 on [1-13C]lactate as the sole carbon source witheither trimethylamine N-oxide (TMAO) or fumarate as an electron acceptor.Analysis of cellular metabolites indicates that a large percentage(>75 percent) of lactate was partially oxidized to either acetate orpyruvate. The 13C isotope distributions in amino acids and other keymetabolites indicate that, under anaerobic conditions, a complete serinepathway is not present, and lactate is oxidized via a highly reversibleserine degradation pathway. The labeling data also suggest significantactivity in the anaplerotic (malic enzyme and phosphoenolpyruvatecarboxylase) and glyoxylate shunt (isocitrate lyase and malate synthase)reactions. Although the tricarboxylic acid (TCA) cycle is often observedto be incomplete in many other anaerobes (absence of 2-oxoglutaratedehydrogenase activity), isotopic labeling supports the existence of acomplete TCA cycle in S. oneidensis MR-1 under TMAO reductioncondition.

  14. Liver perfusion scintigraphy prior to and after transjugular intrahepatic portosystemic shunts (TIPS) in patients with portal hypertension

    International Nuclear Information System (INIS)

    Willkomm, P.; Schomburg, A.; Reichmann, K.; Bangard, M.; Overbeck, B.; Biersack, H.J.; Brensing, K.A.; Sauerbruch, T.

    2000-01-01

    Purpose: This investigation was performed to compare the hemodynamic results of the transjugular intrahepatic portosystemic shunt, a new interventional treatment for portal hypertension, with those observed after the established surgical shunt interventions. Methods: We examined 22 patients with portal hypertension due to liver cirrhosis before and after elective TIPS by liver perfusion scintigraphy. The relative portal perfusion was determined before and after the shunt procedure. Additionally, we measured the portal pressure gradient (PPG: Portal-central venous pressure, mmHg). Results: Prior to TIPS, the relative portal perfusion was significantly reduced to 22±9.1%. After the intervention we calculated values of 23.1±10.7% in the TIPS-group (p=0.67; not significant). In spite of unchanged portal perfusion, the portal pressure was significantly (p [de

  15. [Mesenteric-cava shunt's results with autologous jugular vein graft in children with pre-sinusoidal portal hypertension].

    Science.gov (United States)

    Leal, N; López Santamaría, M; Gámez, M; Murcia, J; Andolfi, G; Berrocal, T; Frauca, E; Jara, P; Tovar, J

    2002-07-01

    Presinusoidal portal hypertension (PPH) in children evaluates without functional hepatic damage, and with the time, trends to compensate through the creation of spontaneous portosystemic shunts. Nevertheless, some patients suffer episodes of gastrointestinal bleeding (GIB) that because of its frequency or severity, force to propose the change of surgical treatment. To evaluate the results of the mesocaval shunt (MCS) with autologous jugular vein in children with PPH. Among the 32 children with PPH treated in our Hospital in the last 7 years, 10 had episodes of GIB that forced to perform a surgical shunt. The types of shunt were distal splenorenal in 3 patients and mesocaval in 7. These 7 cases are the material of this study. The origin of the PPH was a cavernomatosis transformation of the portal vein in 6 cases and a congenital hepatic fibrosis in 1. Before the surgery the average number of episodes of GIB was 9 (range 2-15); all the patients needed transfusion of blood products and variceal sclerosis. In 2 cases a tamponade with the Sengtaken balloon was required and 5 patients were treated with somatostatin and propranolol. The Doppler ultrasounds revealed and intense hepatofugal collateral circulation in all the cases. The initial flow through the shunt was adequate in all the patients except one who required a percutaneous balloon dilatation. Only this patient has suffered an episode of GIB. The hyperesplenism signs disappeared or improved in all the seven cases and the collateral circulation was significantly reduced. The pressure in the splenic territory decreased around 50% in the 4 patients that was measured. There were no cases of encephalopasty and only one child with congenital hepatic fibrosis shows signs of mild hepatic disfunction. The medium follow up post-shunt is 32 months (range 8 m-6 years). The MCS prevents the GIB in the PPH not responsive to the conservative treatment; its effectiveness is related with an adequate permeability though the graft

  16. The Impact of Atrial Left-to-Right Shunt on Pulmonary Hypertension in Preterm Infants with Moderate or Severe Bronchopulmonary Dysplasia

    Directory of Open Access Journals (Sweden)

    Eui Kyung Choi

    2015-10-01

    Conclusion: The presence of an atrial left-to-right shunt was associated with PH in preterm infants with moderate or severe BPD. Close follow up is needed for infants with interatrial shunts, and a more tailored prognostic evaluation and treatment are recommended.

  17. Three major coronary artery-to-left ventricular shunts: Report of three cases and review of literature

    International Nuclear Information System (INIS)

    Nawa, Sugato; Miyachi, Yasuo; Toshino, Norihide; Shiba, Takeshi; Hayashi, Kenji; Tamesue, Kiyokazu; Yamamoto, Hiroshi; Shimizu, Nobuyoshi

    1997-01-01

    Among the congenital coronary artery fistulas, diffuse fistulation into the left ventricular chamber, usually expressed in terms of a coronary artery-left ventricular shunt, is not as rare today as was previously thought. However, the origin of such a shunt from all three major coronary arteries is rare. This paper reports three cases of such an occurrence and presents the clinical features and management of this rare anomaly by analyzing 31 cases, including 28 from the literature

  18. Creating interatrial shunts in heart failure and pulmonary hypertension

    DEFF Research Database (Denmark)

    Wolsk, Emil; Gustafsson, Finn

    2016-01-01

    Patients with elevated filling pressures are at increased risk of adverse cardiovascular (CV) outcomes. Structural interventions to lower elevated either left or right atrial filling pressures are gaining attention. Studies in heart failure show that lowering left atrial pressure may reduce CV...... interatrial device shunt therapy a part of our armamentarium in patients with heart failure or pulmonary hypertension and increased filling pressure....

  19. Integrating rolling stock scheduling with train unit shunting

    DEFF Research Database (Denmark)

    Haahr, Jørgen Thorlund; Lusby, Richard Martin

    2017-01-01

    In this paper, we consider integrating two important railway optimization problems, in particular the Rolling Stock Scheduling Problem and the Train Unit Shunting Problem. We present two similar branch-and-cut based approaches to solve this integrated problem and, in addition, provide a comparison......, sequential approach ends in infeasibility. Furthermore, for the considered instances, solutions are typically found within a few minutes, indicating the applicability of the methodology to short-term planning....

  20. Hysteresis Control for Shunt Active Power Filter under Unbalanced Three-Phase Load Conditions

    Directory of Open Access Journals (Sweden)

    Z. Chelli

    2015-01-01

    Full Text Available This paper focuses on a four-wire shunt active power filter (APF control scheme proposed to improve the performance of the APF. This filter is used to compensate harmonic distortion in three-phase four-wire systems. Several harmonic suppression techniques have been widely proposed and applied to minimize harmonic effects. The proposed control scheme can compensate harmonics and reactive power of the nonlinear loads simultaneously. This approach is compared to the conventional shunt APF reference compensation strategy. The developed algorithm is validated by simulation tests using MATLAB Simulink. The obtained results have demonstrated the effectiveness of the proposed scheme and confirmed the theoretical developments for balanced and unbalanced nonlinear loads.

  1. Iridium-191m radionuclide angiocardiography detection and quantitation of left-to-rigth shunts

    International Nuclear Information System (INIS)

    Treves, S.; Fujii, A.; Cheng, C.; Kuruc, A.

    1983-01-01

    The purpose of this study was to determine whether Iridium-191m (Ir-191m) could replace Technetium-99m (Tc-99m) in the detection and quantitation of left-to-right shunts. It was demonstrated that Ir-191m radionuclide angiography is a safe, rapid, and accurate method for the detection and quantitation of left-to-right shunts with very low radiation dose to the patient. It is also possible with this radiotracer to evaluate other aspects of the anatomy and physiology of the circulation such as ventricular function, patency of major vessels, renal and cerebral perfusion. Further improvements on 0s-191 production, generator design and gamma cameras would expand the use of this ultrashort-lived radionuclide

  2. Injury of leg somatotopy of corticospinal tract at corona radiata by ventriculoperitoneal shunt: A case report.

    Science.gov (United States)

    Jang, Sung Ho; Kwon, Younghyeon

    2018-03-01

    A 45-year-old right-handed female patient suffered head trauma after being hit by a truck that ran into a house. The patient lost consciousness for 1 hour and experienced posttraumatic amnesia for 1 month after the accident. She underwent conservative management for a subdural hematoma in the left frontotemporal lobes and intracerebral hematoma in the left frontal lobe. The patient's Glasgow Coma Scale score was 11. She underwent a VP shunt operation, approached through the right posterior parietal area of the brain, at 4 months after onset. Approximately, 6 months after onset, she was admitted to the rehabilitation department of a university hospital. She presented with moderate weakness of the left leg: Medical Research Council scores: hip flexor; 3, knee extensor; 3+, ankle dorsiflexor; 3-. Brain magnetic resonance imaging revealed a leukomalactic lesion in the right posterior corona radiata along the shunt. On 6-month (2 months after the shunt operation) diffusion tensor tractography, the left CST showed partial injury in the posterior portion compared with the right CST. On 6-month transcranial magnetic stimulation study, the motor-evoked potential obtained at the left tibialis anterior muscle revealed lower amplitude than that on the right side. Injury of leg somatotopy of a CST was demonstrated in a patient with leg weakness following a VP shunt operation.

  3. External thoracic duct-venous shunt in conscious pigs for long term studies of connective tissue metabolites in lymph

    DEFF Research Database (Denmark)

    Jensen, L T; Olesen, H P; Risteli, J

    1990-01-01

    An experimental animal model for lymph studies is described. Thoracic duct-venous shunt was established in 12 pigs. Shunt patency averaged 5.5 days. The composition of connective tissue metabolites in lymph and serum were investigated during a standardized surgical operation (thoracotomy) under...... instead of dogs and sheep in studies on lymph. The effect of surgery/anesthesia must be taken into consideration....

  4. Anatomical Closure of Left-to-Right Shunts in Premature Infants with Bronchopulmonary Dysplasia and Pulmonary Hypertension: A Cautionary Tale

    Directory of Open Access Journals (Sweden)

    Narendra R. Dereddy

    2015-10-01

    Full Text Available Closure of a systemic to pulmonary shunt in premature infants with bronchopulmonary dysplasia may be beneficial, but in the presence of pulmonary hypertension is controversial. Here, we discuss two premature infants with pulmonary hypertension who developed acute pulmonary hypertensive crisis after closure of these shunts and hence advise caution.

  5. Use of i.v. radionuclide total body arteriography to evaluate arterial bypass shunts--a new method--a review of several cases

    International Nuclear Information System (INIS)

    Yang, D.C.; Jain, C.U.; Patel, D.; Gould, L.; Schaefer, H.; Maghazeh, P.; Giovanniello, J.

    1990-01-01

    Currently, Doppler ultrasound and contrast angiography are the main imaging procedures being used to evaluate arterial bypass shunts. IV radionuclide total body arteriography (TBA) is another useful imaging procedure for evaluation of bypass shunts. The authors reviewed 33 patients, 19 women and 14 men, ranging in age from forty-three to eighty-five, who had TBA done after arterial bypass surgery. Ten patients had multiple shunts and 5 had multiple follow-up studies. In total there were 80 shunts, including 43 femoropopliteal, 16 axillofemoral, 1 axillopopliteal, 13 crossover femorofemoral, and 7 aortofemoral shunts. Sixty-two of the 80 shunts were patent, 14 were occluded, and 4 had partial occlusion. The results were confirmed by Doppler studies, contrast angiograms, and/or surgical exploration without false positives or false negatives. Since the radiotracer used was 99mTc-labeled red blood cells, a MUGA study can also be performed immediately following TBA in the same injection. Twenty-eight patients had gated cardiac blood pool studies (MUGA) done; 16 had abnormal wall motion and diminished ventricular function. TBA requires only a single IV injection of radiotracer (less than 1 cc) in the upper limb. The imaging times for total body arterial and perfusion images are seventy seconds and five minutes respectively. Both total body arterial and perfusion images clearly demonstrated the entire course of shunts (single or multiple); underlying and coexisting arterial abnormalities, e g, occlusive disease (27 patients), or aneurysm (3 patients); and related perfusion changes in the extremities. TBA has unique features. It permits a complete, excellent visualization of the bypass graft without the hazard of contrast media injection. It is a simple and a virtually noninvasive procedure, particularly useful for preoperative workups and postoperative follow-ups

  6. Design, control, and implementation of LCL-filter-based shunt active power filters

    DEFF Research Database (Denmark)

    Tang, Yi; Loh, Poh Chiang; Wang, Peng

    2011-01-01

    This paper concentrates on the design, control and implementation of an LCL-filter-based shunt active power filter (SAPF), which can effectively compensate harmonic currents produced by nonlinear loads in a three-phase three-wire power system. The use of LCL-filter at the output end of SAPF offer......-loop control system, and active damping implemented with fewer current sensors are all addressed here. An analytical design example is finally presented, being supported with experimental results, to verify its effectiveness and practicality.......This paper concentrates on the design, control and implementation of an LCL-filter-based shunt active power filter (SAPF), which can effectively compensate harmonic currents produced by nonlinear loads in a three-phase three-wire power system. The use of LCL-filter at the output end of SAPF offers...

  7. Double-Balloon-Assisted n-Butyl-2-Cyanoacrylate Embolization of Intrahepatic Arterioportal Shunt Prior to Chemoembolization of Hepatocellular Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Takao, Hidemasa, E-mail: takaoh-tky@umin.ac.jp; Shibata, Eisuke; Ohtomo, Kuni [University of Tokyo, Department of Radiology, Graduate School of Medicine (Japan)

    2016-10-15

    A case of multiple hepatocellular carcinomas with a severe intrahepatic arterioportal shunt that was successfully embolized with n-butyl-2-cyanoacrylate with coaxial double-balloon occlusion prior to transcatheter arterial chemoembolization is presented. A proximal balloon positioned at the proper hepatic artery was used for flow control, and a coaxial microballoon, positioned in the closest of three arterial feeding branches to the arterioportal shunt, was used to control the delivery of n-butyl-2-cyanoacrylate. This coaxial double-balloon technique can prevent proximal embolization and distal migration of n-butyl-2-cyanoacrylate and enable precise control of the distribution of n-butyl-2-cyanoacrylate. It could also be applicable to n-butyl-2-cyanoacrylate embolization for other than intrahepatic arterioportal shunt.

  8. Intracranial pressure monitoring in pediatric and adult patients with hydrocephalus and tentative shunt failure: a single-center experience over 10 years in 146 patients.

    Science.gov (United States)

    Sæhle, Terje; Eide, Per Kristian

    2015-05-01

    OBJECT In patients with hydrocephalus and shunts, lasting symptoms such as headache and dizziness may be indicative of shunt failure, which may necessitate shunt revision. In cases of doubt, the authors monitor intracranial pressure (ICP) to determine the presence of over- or underdrainage of CSF to tailor management. In this study, the authors reviewed their experience of ICP monitoring in shunt failure. The aims of the study were to identify the complications and impact of ICP monitoring, as well as to determine the mean ICP and characteristics of the cardiac-induced ICP waves in pediatric versus adult over- and underdrainage. METHODS The study population included all pediatric and adult patients with hydrocephalus and shunts undergoing diagnostic ICP monitoring for tentative shunt failure during the 10-year period from 2002 to 2011. The patients were allocated into 3 groups depending on how they were managed following ICP monitoring: no drainage failure, overdrainage, or underdrainage. While patients with no drainage failure were managed conservatively without further actions, over- or underdrainage cases were managed with shunt revision or shunt valve adjustment. The ICP and ICP wave scores were determined from the continuous ICP waveforms. RESULTS The study population included 71 pediatric and 75 adult patients. There were no major complications related to ICP monitoring, but 1 patient was treated for a postoperative superficial wound infection and another experienced a minor bleed at the tip of the ICP sensor. Following ICP monitoring, shunt revision was performed in 74 (51%) of 146 patients, while valve adjustment was conducted in 17 (12%) and conservative measures without any actions in 55 (38%). Overdrainage was characterized by a higher percentage of episodes with negative mean ICP less than -5 to -10 mm Hg. The ICP wave scores, in particular the mean ICP wave amplitude (MWA), best differentiated underdrainage. Neither mean ICP nor MWA levels showed any

  9. Diffusive oxygen shunting between vessels in the preglomerular renal vasculature: anatomic observations and computational modeling.

    Science.gov (United States)

    Gardiner, Bruce S; Thompson, Sarah L; Ngo, Jennifer P; Smith, David W; Abdelkader, Amany; Broughton, Brad R S; Bertram, John F; Evans, Roger G

    2012-09-01

    To understand how geometric factors affect arterial-to-venous (AV) oxygen shunting, a mathematical model of diffusive oxygen transport in the renal cortex was developed. Preglomerular vascular geometry was investigated using light microscopy (providing vein shape, AV separation, and capillary density near arteries) and published micro-computed tomography (CT) data (providing vessel size and AV separation; Nordsletten DA, Blackett S, Bentley MD, Ritman EL, Smith NP. IUPS Physiome Project. http://www.physiome.org.nz/publications/nordsletten_blackett_ritman_bentley_smith_2005/folder_contents). A "U-shaped" relationship was observed between the arterial radius and the distance between the arterial and venous lumens. Veins were found to partially wrap around the artery more consistently for larger rather than smaller arteries. Intrarenal arteries were surrounded by an area of fibrous tissue, lacking capillaries, the thickness of which increased from ∼5 μm for the smallest arteries (200-μm diameter). Capillary density was greater near smaller arteries than larger arteries. No capillaries were observed between wrapped AV vessel pairs. The computational model comprised a single AV pair in cross section. Geometric parameters critical in renal oxygen transport were altered according to variations observed by CT and light microscopy. Lumen separation and wrapping of the vein around the artery were found to be the critical geometric factors determining the amount of oxygen shunted between AV pairs. AV oxygen shunting increases both as lumen separation decreases and as the degree of wrapping increases. The model also predicts that capillaries not only deliver oxygen, but can also remove oxygen from the cortical parenchyma close to an AV pair. Thus the presence of oxygen sinks (capillaries or tubules) near arteries would reduce the effectiveness of AV oxygen shunting. Collectively, these data suggest that AV oxygen shunting would be favored in larger vessels common to the

  10. Balloon-Assisted Chemoembolization Using a Micro-Balloon Catheter Alongside a Microcatheter for a Hepatocellular Carcinoma with a Prominent Arterioportal Shunt: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Hoshiai, Sodai, E-mail: hoshiai@sb4.so-net.ne.jp; Mori, Kensaku; Ishiguro, Toshitaka; Konishi, Takahiro; Uchikawa, Yoko [University of Tsukuba Hospital, Department of Diagnostic and Interventional Radiology (Japan); Fukuda, Kuniaki [University of Tsukuba Hospital, Department of Gastroenterology (Japan); Minami, Manabu [University of Tsukuba Hospital, Department of Diagnostic and Interventional Radiology (Japan)

    2017-04-15

    Although transcatheter arterial chemoembolization is one of the established treatments for hepatocellular carcinoma (HCC), it is difficult to treat HCCs with prominent arterioportal (AP) shunts because anticancer drugs and embolic materials migrate into the non-tumorous liver through the AP shunts and may cause liver infarction. We developed a novel method of balloon-assisted chemoembolization using a micro-balloon catheter alongside a microcatheter simultaneously inserted through a single 4.5-Fr guiding sheath, comprising proximal chemoembolization with distal arterial balloon occlusion. We applied this method to treat an HCC with a prominent distal AP shunt induced by previous proton beam therapy and achieved successful chemoembolization without non-tumorous liver infarction under temporal balloon occlusion of a distal AP shunt.

  11. Superior vena cava syndrome associated with right-to left shunt through systemic-to-pulmonary venous collaterals

    International Nuclear Information System (INIS)

    Juan, Yu Hsiang; Saboo, Sachin S.; Anand, Vishal; Chatzizisis, Yiannis S.; Steigner, Michael L.; Lin, Yu Ching

    2014-01-01

    Superior vena cava (SVC) obstruction is associated with the gradual development of venous collaterals. We present a rare form of systemic-to-pulmonary subpleural collateral pathway that developed in the bridging subpleural pulmonary veins in a 54-year-old woman with complete SVC obstruction. This uncommon collateral pathway represents a rare form of acquired right-to-left shunt due to previous pleural adhesions with an increased risk of stroke due to right-to-left venous shunting, which requires lifelong anticoagulation.

  12. Improved passive shunt vibration control of smart piezo-elastic beams using modal piezoelectric transducers with shaped electrodes

    International Nuclear Information System (INIS)

    Vasques, C M A

    2012-01-01

    Modal control and spatial filtering technologies for mitigation of vibration and/or structural acoustics radiation may be achieved through the use of distributed modal piezoelectric transducers with properly shaped electrodes. This approach filters out undesirable and uncontrollable modes over the bandwidth of interest in order to increase the robustness and stability of the controlled structural system, and may also yield higher values of the generalized modal electromechanical coupling coefficient, which is an important design parameter for achieving efficient passive shunt damping design. In this paper the improvements in passive shunt damping performance when using modal piezoelectric transducers with shaped electrodes are investigated for a two-layered resonant-shunted piezo-elastic smart beam structure. An electromechanical one-dimensional equivalent single-layer Euler–Bernoulli analytical model of two-layered smart piezo-elastic beams with arbitrary spatially shaped electrodes is established for modal and uniform electrode designs. The model is verified and validated by comparison with a one-dimensional discrete-layer (layerwise) finite element model, the damping performance of the shunted smart beam with shaped electrodes is investigated and assessed in terms of the generalized electromechanical coupling coefficient and frequency responses obtained when considering uniform and modally shaped electrodes and the underlying improved performance and advantages are assessed and discussed. (paper)

  13. Predictors and outcomes of shunt-dependent hydrocephalus in patients with aneurysmal sub-arachnoid hemorrhage

    Science.gov (United States)

    2012-01-01

    Background Hydrocephalus following spontaneous aneurysmal sub-arachnoid hemorrhage (SAH) is often associated with unfavorable outcome. This study aimed to determine the potential risk factors and outcomes of shunt-dependent hydrocephalus in aneurysmal SAH patients but without hydrocephalus upon arrival at the hospital. Methods One hundred and sixty-eight aneurysmal SAH patients were evaluated. Using functional scores, those without hydrocephalus upon arrival at the hospital were compared to those already with hydrocephalus on admission, those who developed it during hospitalization, and those who did not develop it throughout their hospital stay. The Glasgow Coma Score, modified Fisher SAH grade, and World Federation of Neurosurgical Societies grade were determined at the emergency room. Therapeutic outcomes immediately after discharge and 18 months after were assessed using the Glasgow Outcome Score. Results Hydrocephalus accounted for 61.9% (104/168) of all episodes, including 82 with initial hydrocephalus on admission and 22 with subsequent hydrocephalus. Both the presence of intra-ventricular hemorrhage on admission and post-operative intra-cerebral hemorrhage were independently associated with shunt-dependent hydrocephalus in patients without hydrocephalus on admission. After a minimum 1.5 years of follow-up, the mean Glasgow outcome score was 3.33 ± 1.40 for patients with shunt-dependent hydrocephalus and 4.21 ± 1.19 for those without. Conclusions The presence of intra-ventricular hemorrhage, lower mean Glasgow Coma Scale score, and higher mean scores of the modified Fisher SAH and World Federation of Neurosurgical grading on admission imply risk of shunt-dependent hydrocephalus in patients without initial hydrocephalus. These patients have worse short- and long-term outcomes and longer hospitalization. PMID:22765765

  14. Degradation sources of CdTe thin film PV: CdCl{sub 2} residue and shunting pinholes

    Energy Technology Data Exchange (ETDEWEB)

    Gorji, Nima E. [University of Bologna, Department of Electrical, Electronics and Information Engineering, Bologna (Italy)

    2014-09-15

    The present work considers two observable phenomena through the experimental fabrication and electrical characterization of the rf-sputtered CdS/CdTe thin film solar cells that extremely reduce the overall conversion efficiency of the device: CdCl{sub 2} residue on the surface of the semiconductor and shunting pinholes. The former happens through nonuniform treatment of the As-deposited solar cells before annealing at high temperature and the latter occurs by shunting pinholes when the cell surface is shunted by defects, wire-like pathways or scratches on the metallic back contact caused from the external contacts. Such physical problems may be quite common in the experimental activities and reduce the performance down to 4-5 % which leads to dismantle the device despite its precise fabrication. We present our electrical characterization on the samples that received wet CdCl{sub 2} surface treatment (uniform or nonuniform) and are damaged by the pinholes. (orig.)

  15. Determination of blood flow through arteriovenous fistulae and shunts

    International Nuclear Information System (INIS)

    Lantz, B.M.T.; Holcroft, J.W.; Foerster, J.M.; Link, D.P.; Reid, M.H.

    1979-01-01

    A videodensitometric method for estimating relative flow was employed in a patient with a bovine arteriovenous fistula. Analogous arteriovenous communications of different sizes were created in two dogs for comparison. Local and general hemodynamic parameters were measured. The videodensitometric method proved to be highly accurate compared to electromagnetic flow readings and is the method of choice in estimating shunt flow in connection with routine angiography. (Auth.)

  16. Creation of an iliac arteriovenous shunt lowers blood pressure in chronic obstructive pulmonary disease patients with hypertension.

    LENUS (Irish Health Repository)

    Faul, John

    2014-01-28

    Vasodilators are used with caution in patients with chronic obstructive pulmonary disease (COPD). We have developed a device for percutaneous arteriovenous shunt creation in the iliac region to increase cardiac output and oxygen delivery for patients with COPD. Although this device does not cause significant blood pressure changes in normotensive patients with COPD, we hypothesized that arteriovenous shunt creation might cause vasodilator effects in hypertensive patients because of a reduction in vascular resistance.

  17. Warren shunt combined with partial splenectomy in children with extra-hepatic portal hypertension, massive splenomegaly and severe hypersplenism

    Directory of Open Access Journals (Sweden)

    Sretenović Aleksandar

    2014-01-01

    Full Text Available Introduction. Extra-hepatic portal vein obstruction (EHPVO is one of the most often causes of portal hypertension in children. Objective. Establishing the importance of shunt surgery in combination with partial spleen resection in selected pediatric patients with EHPVO, enormous splenomegaly and severe hypersplenism. Methods. Distal splenorenal shunt (DSRS with partial spleen resection was performed in 22 children age from 2 to 17 years with EHPVO. Indications for surgery were pain and abdominal discomfort caused by spleen enlargement, as well as symptomatic hypersplenism with leucopenia, thrombocytopenia and anemia. The partial spleen resection was performed by ligation of blood vessels to caudal two thirds of the spleen. After ischemic parenchymal demarcation transection with electrocautery LigaSure was performed with preservation of 20-30% of spleen tissue, and then Warren DSRS was created. Platelet and leucocytes counts and liver function tests were obtained before, one month and one year after surgery. Growth was assessed with SD scores (Z scores for height, weight and body mass index at the time of surgery and one year later. Results. In all patients postoperative period was without significant complications. Platelets and leucocytes counts were normalized. Patency rate of shunts was 100%. Two significant shunts stenosis were observed and successfully treated with percutaneous angioplasty. During the follow-up period (1 to 9 years all patients were asymptomatic, with improved quality of life and growth. Conclusion. Results of our study indicate that shunt surgery with a partial spleen resection is an effective and safe procedure for patients with enormous splenomegaly and severe hypersplenism caused by EHPVO.

  18. Effect of amusement park rides on programmable shunt valve settings.

    Science.gov (United States)

    Strahle, Jennifer; Collins, Kelly; Stetler, William R; Smith, Brandon W; Garton, Thomas; Garton, Catherine; Garton, Hugh J L; Maher, Cormac O

    2013-01-01

    Magnetically programmable shunt valves are susceptible to environmental factors including magnetic fields and accelerative forces. It is unknown if rollercoasters with or without magnetic brakes or linear induction motors (LIMs) are capable of altering the setting of a programmable shunt valve. Two different valve types (type A, n = 10; type B, n = 9) were tested at varying resistance settings in 2 trials on 6 different amusement park rides including 2 rides with LIMs, 2 rides with magnetic brakes, and 2 rides without magnetic technology. The performance level of valve type A and the setting of valve type B changed on rollercoasters with magnets (A = 2.5% [2/80]; B = 5.6% [4/72]) and without magnets (A = 7.5% [3/40]; B = 2.8% [1/36]). Neither valve setting changed when exposed to a Ferris wheel or during ambulation throughout the park. Magnetically programmable valves are susceptible to changes in pressure settings when exposed to amusement park rides with elevated vertical gravitational forces, irrespective of the presence of LIMs or magnetic brakes. © 2013 S. Karger AG, Basel.

  19. Effect of Abrasive Machining on the Electrical Properties Cu86Mn12Ni₂ Alloy Shunts.

    Science.gov (United States)

    Misti, Siti Nabilah; Birkett, Martin; Penlington, Roger; Bell, David

    2017-07-29

    This paper studies the effect of abrasive trimming on the electrical properties of Cu 86 Mn 12 Ni₂ Manganin alloy shunt resistors. A precision abrasive trimming system for fine tuning the resistance tolerance of high current Manganin shunt resistors is proposed. The system is shown to be capable of reducing the resistance tolerance of 100 μΩ shunts from their standard value of ±5% to <±1% by removing controlled amounts of Manganin material using a square cut trim geometry. The temperature coefficient of resistance (TCR), high current, and high temperature performance of the trimmed shunts was compared to that of untrimmed parts to determine if trimming had any detrimental effect on these key electrical performance parameters of the device. It was shown that the TCR value was reduced following trimming with typical results of +106 ppm/°C and +93 ppm/°C for untrimmed and trimmed parts respectively. When subjected to a high current of 200 A the trimmed parts showed a slight increase in temperature rise to 203 °C, as compared to 194 °C for the untrimmed parts, but both had significant temporary increases in resistance of up to 1.3 μΩ. The results for resistance change following high temperature storage at 200 °C for 168 h were also significant for both untrimmed and trimmed parts with shifts of 1.85% and 2.29% respectively and these results were related to surface oxidation of the Manganin alloy which was accelerated for the freshly exposed surfaces of the trimmed part.

  20. Cyst formation after radiosurgery for brain arteriovenous malformation treated with cystoperitoneal shunt

    International Nuclear Information System (INIS)

    Morihiro, Yusuke; Kato, Syoichi; Imoto, Hirochika

    2010-01-01

    Gamma knife and CyberKnife radiosurgery are well established and less invasive treatments for arteriovenous malformation. Delayed cyst formation is a rare but well-known complication of radiosurgery for arteriovenous malformations. The optimal treatment of cysts forming after radiosurgery remains debatable. We present a case of cyst formation after radiosurgery for brain arteriovenous malformation that was treated with a cystoperitoneal shunt (C-P shunt). A 36-year-old woman presented with left hemiparesis and numbness. Computed tomography (CT) revealed intracranial hemorrhage in the right basal ganglia. Digital subtraction angiography revealed arteriovenous malformation in the brain. Intravascular embolization was performed three times and radiosurgery was performed twice, whereby complete obliteration of the nidus was achieved. Six and a half years later, routine follow-up magnetic resonance imaging revealed cyst formation, and the patient gradually developed left hemiparesis. First, we performed stereotactic cyst aspiration. This initially resulted in a reduction in the size of the cyst and disappearance of left hemiparesis, but within a short time, the cyst increased in size again and there was recurrence of hemiparesis. Therefore, an Ommaya reservoir was established; aspiration of the cyst through this reservoir brought about an initial reduction in cyst size and alleviation of symptoms; however, no further reduction in cyst size or improvement in symptoms could be achieved. Twenty months after the placement of the Ommaya reservoir, we performed a C-P shunt operation. After the operation, further reduction in the cyst size and complete symptomatic recovery were observed. (author)

  1. Comparative performance analysis of shunt and series passive filter for LED lamp

    Science.gov (United States)

    Sarwono, Edi; Facta, Mochammad; Handoko, Susatyo

    2018-03-01

    Light Emitting Diode lamp or LED lamp nowadays is widely used by consumers as a new innovation in the lighting technologies due to its energy saving for low power consumption lamps for brighter light intensity. How ever, the LED lamp produce an electric pollutant known as harmonics. The harmonics is generated by rectifier as part of LED lamp circuit. The present of harmonics in current or voltage has made the source waveform from the grid is distorted. This distortion may cause inacurrate measurement, mall function, and excessive heating for any element at the grid. This paper present an analysis work of shunt and series filters to suppress the harmonics generated by the LED lamp circuit. The work was initiated by conducting several tests to investigate the harmonic content of voltage and currents. The measurements in this work were carried out by using HIOKI Power Quality Analyzer 3197. The measurement results showed that the harmonics current of tested LED lamps were above the limit of IEEE standard 519-2014. Based on the measurement results shunt and series filters were constructed as low pass filters. The bode analysis were appled during construction and prediction of the filters performance. Based on experimental results, the application of shunt filter at input side of LED lamp has reduced THD current up to 88%. On the other hand, the series filter has significantly reduced THD current up to 92%.

  2. Evaluation of the degree of arteriovenous shunting in intracranial arteriovenous malformations using pseudo-continuous arterial spin labeling magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sunwoo, Leonard; Park, Sun-Won [Seoul Metropolitan Government - Seoul National University Boramae Medical Center, Department of Radiology, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Sohn, Chul-Ho; Yun, Tae Jin; Choi, Seung Hong; Cho, Young Dae; Kim, Ji-hoon; Han, Moon Hee [Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Lee, Jong Young [Kangdong Sacred Heart Hospital, Department of Neurosurgery, Seoul (Korea, Republic of); Yi, Kyung Sik [Chungbuk National University Hospital, Department of Radiology, Cheongju (Korea, Republic of); Paek, Sun Ha; Kim, Yong Hwy; Kim, Jin Wook; Chung, Hyun-Tai; Kim, Dong Gyu [Seoul National University Hospital, Department of Neurosurgery, Seoul (Korea, Republic of)

    2015-08-15

    Intracranial arteriovenous malformations (AVMs) display venous signals on arterial spin labeling (ASL) magnetic resonance (MR) imaging due to the presence of arteriovenous shunting. Our aim was to quantitatively correlate AVM signal intensity on ASL with the degree of arteriovenous shunting estimated on digital subtraction angiography (DSA) in AVMs. MR imaging including pseudo-continuous ASL at 3 T and DSA were obtained on the same day in 40 patients with intracranial AVMs. Two reviewers assessed the nidus and venous signal intensities on ASL images to determine the presence of arteriovenous shunting. Interobserver agreement on ASL between the reviewers was determined. ASL signal intensity of the AVM lesion was correlated with AVM size and the time difference between normal and AVM venous transit times measured from the DSA images. Interobserver agreement between two reviewers for nidus and venous signal intensities was excellent (κ = 0.80 and 1.0, respectively). Interobserver agreement regarding the presence of arteriovenous shunting was perfect (κ = 1.0). AVM signal intensity showed a positive relationship with the time difference between normal and AVM venous transit times (r = 0.638, P < 0.001). AVM signal intensity also demonstrated a positive relationship with AVM size (r = 0.561, P < 0.001). AVM signal intensity on ASL in patients with AVM correlates well with the degree of early vein opacification on DSA, which corresponds to the degree of arteriovenous shunting. (orig.)

  3. Neurological and neuropsychological effects of cerebral spinal fluid shunting in children with assumed arrested ("normal pressure") hydrocephalus.

    Science.gov (United States)

    Torkelson, R D; Leibrock, L G; Gustavson, J L; Sundell, R R

    1985-08-01

    Normocephalic children found to have ventriculomegaly during evaluation of long-standing (4.5-8.5 years) neurological disorder were tested for academic achievement, intellectual quotient and neuropsychological functioning. Radioactive iodinated serum cisternography, pre and post-shunt electrophysiological studies (visual evoked responses, brainstem auditory evoked potentials, sleep electroencephalograms) and radiological studies (skull radiographs computed tomography) were recorded. Four children who have been followed more than one year after insertion of ventricular-peritoneal shunts are presented. All demonstrated improvement in psychometric findings along with some improvement in CT scan and EEG studies. The most marked initial changes were noted on measures of neuropsychological performance, accompanied later by improvement in measures of intelligence. Achievement test scores showed no consistent pattern of change. This sample suggests that there is a group of asymptomatic children with apparent clinically stable (arrested) hydrocephalus in whom abnormal neuropsychological testing indicates the need for cerebrospinal fluid shunting, with subsequent improvement.

  4. Radionuclide detection and differential diagnosis of left-to-right cardiac shunts by analysis of time-activity curves

    International Nuclear Information System (INIS)

    Kim, Ok-Hwa

    1986-01-01

    The noninvasive nature of the radionuclide angiocardiography provided a useful approach for the evaluation of left-to-right cardiac shunts (LRCS). While the qualitative information can be obtained by inspection of serial radionuclide angiocardiograms, the quantitative information of radionuclide angiocardiography can be obtained by the analysis of time-activity curves using advanced computer system. The count ratios method and pulmonary-to-systemic flow ratio (QP/QS) by gamma variate fit method were used to evaluate the accuracy of detection and localization of LRCS. One hundred and ten time-activity curves were analyzed. There were 46 LRCS (atrial septal defects 11, ventricular septal defects 22, patent ductus arteriosus 13) and 64 normal subjects. By computer analysis of time-activity histograms of the right atrium, ventricle and the lungs separately, the count ratios modified by adding the mean cardiac transit time were calculated in each anatomic site. In normal subjects the mean count ratios in the right atrium, ventricle and lungs were 0.24 on average. In atrial septal defects, the count ratios were high in the right atrium, ventricle and lungs, whereas in ventricular septal defects the count ratios were higher only in the right ventricle and lungs. Patent ductus arteriosus showed normal count ratios in the heart but high count ratios were obtained in the lungs. Thus, this count ratios method could be separated normal from those with intracardiac or extracardiac shunts, and moreover, with this method the localization of the shunts level was possible in LRCS. Another method that could differentiate the intracardiac shunts from extracardiac shunts was measuring QP/QS in the left and right lungs. In patent ductus arteriosus, the left lung QP/QS was hight than those of the right lung, whereas in atrial septal defects and ventricular septal defects QP/QS ratios were equal in both lungs. (J.P.N.)

  5. Comparison of findings of spontaneous splenorenal shunt in color Doppler sonography with multislice CT scan (64 slices) in liver transplant candidates

    Energy Technology Data Exchange (ETDEWEB)

    Bagheri, Mohammadhadi, E-mail: Bagherimh@gmail.com [Department of Radiology, Shiraz University of Medical Sciences, Namazi Hospital, Shiraz (Iran, Islamic Republic of); Hajati, Azadeh, E-mail: azadeh.hajati@gmail.com [Department of Radiology, Shiraz University of Medical Sciences, Namazi Hospital, Shiraz (Iran, Islamic Republic of); Hosseini, Mohammadkazem, E-mail: hosseiniaslm@sums.ac.ir [Department of Radiology, Shiraz University of Medical Sciences, Namazi Hospital, Shiraz (Iran, Islamic Republic of); Ostad, Seyed Pouria, E-mail: Pouria.Ostad@gmail.com [Department of Radiology, Shiraz University of Medical Sciences, Namazi Hospital, Shiraz (Iran, Islamic Republic of)

    2012-09-15

    Background: Liver transplantation is the only definite treatment for end stage liver disease and it has high costs for the medical system so decreasing its complication and increasing its effectiveness is crucial. One of the factors that affect liver transplantation is the presence of spontaneous splenorenal shunt. Its diagnosis is mainly overlooked in pre-liver transplant patients. Main modality for its diagnosis is multislice CT scan however this is more expensive than sonography. Also, it exposes the patients to ionizing radiation. Considering the advantages of color Doppler ultrasound, studies to determine the sensitivity and specificity for detection of spontaneous splenorenal shunt is essential. Materials and methods: In our study 70 cirrhotic patients who were referred by liver transplant surgeons for evaluation of abdomen by CT and sonograhy were assessed for presence of spontaneous splenorenal shunt, left adrenal varix and left renal vein diameter and velocity and sensitivity and specificity of both modalities were checked. Patients in whom left renal vein could not evaluated by sonography and patients with splenectomy and nutcracker syndrome were excluded. Results: In the point of 10 mm diameter of left renal vein in CT scan there was 78.6% sensitivity and 67.9% specificity for the presence of spontaneous splenorenal shunt. Left adrenal varix in CT had sensitivity of 71.4%, specificity of 100%, and positive predictive value of 100% and negative predictive value of 70% and varix below spleen in CT had sensitivity of 54.8%, specificity of 96.4%, and positive predictive value of 95.8% and negative predictive value of 58.7% for the presence of spontaneous splenorenal shunt. In the point of 8 mm diameter of left renal vein in sonography there was 66.7% sensitivity and 85.7% specificity for the presence of spontaneous splenorenal shunt. For the velocity of more than 35 cm/s of left renal vein in sonography there was 61.9% sensitivity and 82.1% specificity for

  6. Almost periodic solution of shunting inhibitory CNNs with delays

    Science.gov (United States)

    Chen, Anping; Cao, Jinde

    2002-06-01

    Using the Banach fixed point theorem, we obtain a sufficient condition for the existence of almost periodic solution of shunting inhibitory cellular neural networks {dx ij}/{dt}=-a ijx ij- limit∑C kl∈N r(i,j) C ijklf x kl(t-τ) x ij+L ij(t), the global attractivity of SICNNs is also obtained. An example is given to illustrate that the condition of our results are feasible.

  7. Penile artery shunt syndrome: a novel cause of erectile dysfunction after penile revascularization surgery.

    Science.gov (United States)

    Pavlinec, Jonathan G; Hakky, Tariq S; Yang, Christopher; Massis, Kamal; Munarriz, Ricardo; Carrion, Rafael E

    2014-09-01

    Penile revascularization is a surgical treatment option for erectile dysfunction (ED) in healthy individuals due to a focal arterial occlusion in the absence of generalized vascular disease. Most described failures have been attributed to graft stenosis or disruption of the anastomosis. We report a novel phenomenon called Penile Artery Shunt Syndrome that contributed to persistent ED in a patient after penile microvascular arterial bypass surgery. A 26-year-old man presented for evaluation of long-standing ED, which was attributed to trauma sustained 12 years earlier. He had difficulty obtaining and maintaining erections despite oral pharmacotherapy. Clinical data related to the case were studied, analyzed, and reviewed with urologic and radiologic specialists at multiple centers that collaborated in the care of this patient. Penile duplex ultrasound peak systolic velocities and five-item International Index for Erectile Function questionnaire scores were the main outcome measures. Initial diagnostic workup of the patient confirmed severe insufficiency of the left cavernosal artery, with no evidence of venous leak. The patient underwent penile microvascular arterial bypass surgery with anastomosis of the left inferior epigastric artery to the left dorsal penile artery. The patient had persistence of severe ED despite patent anastomosis by penile duplex ultrasound. Subsequent arteriography revealed an arterial shunt due to an aberrant obturator artery arising from the donor inferior epigastric artery. The patient underwent embolization of the aberrant obturator artery, with resolution of the shunt and marked improvement in erectile function. The presence of an aberrant obturator artery arising from the inferior epigastric artery may predispose to persistent ED after revascularization due to the creation of a shunt phenomenon. Pelvic arteriography may be useful in identifying anomalous anatomic considerations prior to penile revascularization and to evaluate patients

  8. Accurate calibration of RL shunts for piezoelectric vibration damping of flexible structures

    DEFF Research Database (Denmark)

    Høgsberg, Jan Becker; Krenk, Steen

    2016-01-01

    Piezoelectric RL (resistive-inductive) shunts are passive resonant devices used for damping of dominantvibration modes of a flexible structure and their efficiency relies on precise calibration of the shuntcomponents. In the present paper improved calibration accuracy is attained by an extension...

  9. Hepatocyte transplants improve liver function and encephalopathy in portacaval shunted rats.

    Science.gov (United States)

    Fogel, Wieslawa Agnieszka; Stasiak, Anna; Maksymowicz, Michał; Kobos, Jozef; Unzeta, Mercedes; Mussur, Miroslaw

    2014-07-01

    Rats with portacaval shunt (PCS) are useful experimental models of human hepatic encephalopathy in chronic liver dysfunction. We have previously shown that PCS modifies amine neurotransmitter systems in the CNS and increases voluntary alcohol intake by rats. Hepatocyte transplantation, used in acute liver failure, has recently also been applied to chronic liver diseases, which prompted us to investigate whether the altered brain amine system and the drinking behavior in long-term shunted rats could be normalized by hepatocyte transplants. Hepatocytes, isolated from syngeneic donors by collagenase digestion, were injected (3 × 10(6) cells/rat) into the pancreatic tail region, 6 months after PCS. Hepatic function was evaluated by measuring urine urea and plasma L-histidine concentrations. A free choice test with two bottles (tap water and 10% ethyl alcohol) was performed for 3 days to assess the rats' preference for alcohol. The rats were euthanized 2 months posttransplantation. Brain histamine and 5-hydroxyindoleacetic acid (5-HIAA) levels were measured by radioenzymatic assay and by HPLC-EC, respectively, N-tele-methylhistamine by GC/MS while MAOA and MAOB activities by isotopic procedures. Portacaval shunt rats with hepatocyte transplants gave more urea than before transplantation, with lower plasma L-His levels and higher body weight versus the PCS counterparts. Also, those rats consumed less alcohol. The CNS amines and 5-HIAA concentrations, as well as MAO-B activity, being abnormally high in untreated PCS rats, significantly reduced after PCS hepatocyte treatment. The results support the therapeutic values of hepatocyte transplants in chronic liver diseases and the temporary character of PCS-exerted CNS dysfunctions. © 2014 John Wiley & Sons Ltd.

  10. A New Approach to Identify Optimal Properties of Shunting Elements for Maximum Damping of Structural Vibration Using Piezoelectric Patches

    Science.gov (United States)

    Park, Junhong; Palumbo, Daniel L.

    2004-01-01

    The use of shunted piezoelectric patches in reducing vibration and sound radiation of structures has several advantages over passive viscoelastic elements, e.g., lower weight with increased controllability. The performance of the piezoelectric patches depends on the shunting electronics that are designed to dissipate vibration energy through a resistive element. In past efforts most of the proposed tuning methods were based on modal properties of the structure. In these cases, the tuning applies only to one mode of interest and maximum tuning is limited to invariant points when based on den Hartog's invariant points concept. In this study, a design method based on the wave propagation approach is proposed. Optimal tuning is investigated depending on the dynamic and geometric properties that include effects from boundary conditions and position of the shunted piezoelectric patch relative to the structure. Active filters are proposed as shunting electronics to implement the tuning criteria. The developed tuning methods resulted in superior capabilities in minimizing structural vibration and noise radiation compared to other tuning methods. The tuned circuits are relatively insensitive to changes in modal properties and boundary conditions, and can applied to frequency ranges in which multiple modes have effects.

  11. Mid-term effect of direct intrahepatic portosystemic shunt for the treatment of portal hypertension

    International Nuclear Information System (INIS)

    Luo Jianjun; Yan Zhiping; Wang Jianhua; Liu Qingxin; Qu Xudong

    2009-01-01

    Objective: To retrospectively analyze the mid-term clinical results of direct intrahepatic portosystemic shunt (DIPS) in treating patients with portal hypertension. Methods: DIPS were created in 23 patients with portal hypertension. Both preoperative and postoperative portal systemic pressure gradient (PPG), liver function and clinical symptoms were recorded and compared. Shunt patency was checked by color Doppler ultrasonography and the data were statistically analyzed by Kaplan-Meier method. Results DIPS creation was successfully accomplished in all 23 patients. No serious complications occurred after DIPS except for hemorrhagic ascites (n = 1) and mild hepatic encephalopathy (n = 3). Mean PPG significantly decreased from preoperative (32.6 ± 5.3) mmHg with a range of (23 - 43) mmHg to postoperative (10.1 ± 2.7) mmHg with a range of (5-14) mmHg (P < 0.001). After the procedure, the albumin level also markedly decreased while the bilirubin level distinctly increased. Obvious improvement of the clinical symptoms was observed. The cumulated primary patency rate of the shunt one and two years after treatment was 77.4% and 50.2% respectively. Conclusion: The mid-term clinical results indicate that DIPS is an effective and safe procedure for treating patients with portal hypertension. (authors)

  12. Liquid breathing - Prevention of pulmonary arterial-venous shunting during acceleration.

    Science.gov (United States)

    Sass, D. J.; Ritman, E. L.; Caskey, P. E.; Banchero, N.; Wood, E. H.

    1972-01-01

    Dependent pulmonary atelectasis, arterial-venous shunting, and downward displacement of the heart caused by the gravitational-inertial force environment were prevented in dogs breathing oxygenated liquid fluorocarbon in a whole-body water-immersion respirator. Partial closure of the major airways during part of the expiratory phase of liquid respiration was a significant problem initially but was minimized in subsequent studies.

  13. Finger tapping and verbal fluency post-tap test improvement in INPH: its value in differential diagnosis and shunt-treatment outcomes prognosis.

    Science.gov (United States)

    Liouta, Evangelia; Gatzonis, Stylianos; Kalamatianos, Theodosis; Kalyvas, Aristotelis; Koutsarnakis, Christos; Liakos, Faidon; Anagnostopoulos, Christos; Komaitis, Spyridon; Giakoumettis, Dimitris; Stranjalis, George

    2017-12-01

    Idiopathic normal pressure hydrocephalus (INPH) diagnosis is challenging as it can be mimicked by other neurological conditions, such as neurodegenerative dementia and motor syndromes. Additionally, outcomes after lumbar puncture (LP) tap test and shunt treatment may vary due to the lack of a common protocol in INPH assessment. The present study aimed to assess whether a post-LP test amelioration of frontal cognitive dysfunctions, characterizing this syndrome, can differentiate INPH from similar neurological conditions and whether this improvement can predict INPH post-shunt outcomes. Seventy-one consecutive patients referred for INPH suspicion and LP testing, were enrolled. According to the consensus guidelines criteria, 29 patients were diagnosed as INPH and 42 were assigned an alternative diagnosis (INPH-like group) after reviewing clinical, neuropsychological and imaging data, and before LP results. A comprehensive neuropsychological assessment for frontal executive, upper extremity fine motor functions, aphasias, apraxias, agnosias and gait evaluation were administered at baseline. Executive, fine motor functions and gait were re-examined post-LP test in all patients and post-shunt placement in INPH patients. Of the INPH patients, 86.2% showed cognitive amelioration in the post-LP test; in addition, all but one (97%) presented with neurocognitive and gait improvement post-shunt. Verbal phonological fluency and finger tapping task post-LP improvement predicted positive clinical outcome post-shunt. None of the INPH-like group presented with neurocognitive improvement post-LP. Post-LP amelioration of verbal fluency and finger tapping deficits can differentiate INPH from similar disorders and predict positive post-shunt clinical outcome in INPH. This becomes of great importance when gait assessment is difficult to perform in clinical practice.

  14. Surgical attenuation of congenital portosystemic shunts in dogs. Techniques, complications and prognosis

    NARCIS (Netherlands)

    Kummeling, A.|info:eu-repo/dai/nl/304828793

    2009-01-01

    The general aim of this thesis was to identify factors associated with outcome after surgical attenuation of congenital portosystemic shunts (CPSS) in dogs and to clarify underlying mechanisms of postoperative recovery in this disease. Two surgical techniques used for CPSS attenuation, ligation and

  15. Optimum design of matrix fault current limiters using the series resistance connected with shunt coil

    Science.gov (United States)

    Chung, D. C.; Choi, H. S.; Lee, N. Y.; Nam, G. Y.; Cho, Y. S.; Sung, T. H.; Han, Y. H.; Kim, B. S.; Lim, S. H.

    2007-10-01

    In this paper we described the improved design for the matrix fault current limiters (MFCL). To do this, we used thin film-type superconducting elements. therefore it means that we can make the MFCL with minimized size and high switching speed because of the high current density and the high indexing value of superconducting thin film. Also we could minimize the bulky shunt coil using the connection of a series resistance with a shunt coil. Also we could effectively block up a leakage current in shunt coils under no-fault condition and simply control total impedances of a current-limiting part using this method. After we designed an appropriated 1 × 2 basic MFCL module with an applied voltage of 160 V, we enlarged it to a 2 × 2 MFCL module and a 3 × 2 MFCL module where applied voltages were 320 V and 480 V, respectively. Experimental results for our MFCL were reported in terms of various fault currents, variation of series resistance and so on. We think that these methods will be useful in the optimum design of an m × n MFCL.

  16. Optimum design of matrix fault current limiters using the series resistance connected with shunt coil

    International Nuclear Information System (INIS)

    Chung, D.C.; Choi, H.S.; Lee, N.Y.; Nam, G.Y.; Cho, Y.S.; Sung, T.H.; Han, Y.H.; Kim, B.S.; Lim, S.H.

    2007-01-01

    In this paper we described the improved design for the matrix fault current limiters (MFCL). To do this, we used thin film-type superconducting elements. therefore it means that we can make the MFCL with minimized size and high switching speed because of the high current density and the high indexing value of superconducting thin film. Also we could minimize the bulky shunt coil using the connection of a series resistance with a shunt coil. Also we could effectively block up a leakage current in shunt coils under no-fault condition and simply control total impedances of a current-limiting part using this method. After we designed an appropriated 1 x 2 basic MFCL module with an applied voltage of 160 V, we enlarged it to a 2 x 2 MFCL module and a 3 x 2 MFCL module where applied voltages were 320 V and 480 V, respectively. Experimental results for our MFCL were reported in terms of various fault currents, variation of series resistance and so on. We think that these methods will be useful in the optimum design of an m x n MFCL

  17. A two-stage approach to the depot shunting driver assignment problem with workload balance considerations.

    Science.gov (United States)

    Wang, Jiaxi; Gronalt, Manfred; Sun, Yan

    2017-01-01

    Due to its environmentally sustainable and energy-saving characteristics, railway transportation nowadays plays a fundamental role in delivering passengers and goods. Emerged in the area of transportation planning, the crew (workforce) sizing problem and the crew scheduling problem have been attached great importance by the railway industry and the scientific community. In this paper, we aim to solve the two problems by proposing a novel two-stage optimization approach in the context of the electric multiple units (EMU) depot shunting driver assignment problem. Given a predefined depot shunting schedule, the first stage of the approach focuses on determining an optimal size of shunting drivers. While the second stage is formulated as a bi-objective optimization model, in which we comprehensively consider the objectives of minimizing the total walking distance and maximizing the workload balance. Then we combine the normalized normal constraint method with a modified Pareto filter algorithm to obtain Pareto solutions for the bi-objective optimization problem. Furthermore, we conduct a series of numerical experiments to demonstrate the proposed approach. Based on the computational results, the regression analysis yield a driver size predictor and the sensitivity analysis give some interesting insights that are useful for decision makers.

  18. Effect of Circuit Breaker Shunt Resistance on Chaotic Ferroresonance in Voltage Transformer

    Directory of Open Access Journals (Sweden)

    RADMANESH, H.

    2010-08-01

    Full Text Available Ferroresonance or nonlinear resonance is a complex electrical phenomenon, which may cause over voltages and over currents in the electrical power system which endangers the system reliability and continuous safe operating. This paper studies the effect of circuit breaker shunt resistance on the control of chaotic ferroresonance in a voltage transformer. It is expected that this resistance generally can cause ferroresonance dropout. For confirmation this aspect Simulation has been done on a one phase voltage transformer rated 100VA, 275kV. The magnetization characteristic of the transformer is modeled by a single-value two-term polynomial with q=7. The simulation results reveal that considering the shunt resistance on the circuit breaker, exhibits a great mitigating effect on ferroresonance over voltages. Significant effect on the onset of chaos, the range of parameter values that may lead to chaos along with ferroresonance voltages has been obtained and presented.

  19. Particle swarm optimization algorithm for simultaneous optimal placement and sizing of shunt active power conditioner (APC) and shunt capacitor inharmonic distorted distribution system

    Institute of Scientific and Technical Information of China (English)

    Mohammadi Mohammad

    2017-01-01

    Due to development of distribution systems and increase in electricity demand, the use of capacitor banks increases. From the other point of view, nonlinear loads generate and inject considerable harmonic currents into power system. Under this condition if capacitor banks are not properly selected and placed in the power system, they could amplify and propagate these harmonics and deteriorate power quality to unacceptable levels. With attention of disadvantages of passive filters, such as occurring resonance, nowadays the usage of this type of harmonic compensator is restricted. On the other side, one of parallel multi-function compensating devices which are recently used in distribution system to mitigate voltage sag and harmonic distortion, performs power factor correction, and improves the overall power quality as active power conditioner (APC). Therefore, the utilization of APC in harmonic distorted system can affect and change the optimal location and size of shunt capacitor bank under harmonic distortion condition. This paper presents an optimization algorithm for improvement of power quality using simultaneous optimal placement and sizing of APC and shunt capacitor banks in radial distribution networks in the presence of voltage and current harmonics. The algorithm is based on particle swarm optimization (PSO). The objective function includes the cost of power losses, energy losses and those of the capacitor banks and APCs.

  20. An Approach to Endovascular and Percutaneous Management of Transjugular Intrahepatic Portosystemic Shunt (TIPS) Dysfunction: A Pictorial Essay and Clinical Practice Algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Keith, E-mail: keithjppereira@gmail.com; Baker, Reginald, E-mail: rbaker@med.miami.edu; Salsamendi, Jason; Doshi, Mehul; Kably, Issam; Bhatia, Shivank [Jackson Memorial Hospital/University of Miami Hospital, Department of Interventional Radiology (United States)

    2016-05-15

    Transjugular intrahepatic portosystemic shunts (TIPS) have evolved as an effective and durable nonsurgical option in the treatment of portal hypertension (PH). It has been shown to improve survival in decompensated cirrhosis and may also serve as a bridge to liver transplantation. In spite of the technical improvements in the procedure, problems occur with the shunt which jeopardizes effective treatment of the PH. Appropriate management is vital to ensure the longevity of the conduit. Shunt revision techniques include endovascular revision techniques and new shunt creation or, in the appropriate patients, alternative/rescue therapies. The ability of interventional radiologists to restore adequate TIPS function has enormous implications for quality of life with palliation, morbidity/mortality related to variceal bleeding and survival if transplant candidates can live long enough to receive a new liver. As such, it is imperative that these treatment strategies are understood and employed when these patients are encountered. In this review, the restoration of appropriate shunt function using various techniques will be discussed as they apply to a variety of clinical scenarios, based on literature. In addition, illustrative case examples highlighting our experience at an academic tertiary medical center will be included. It is the intent to have this document serve as a concise and informative reference to be used by those who may encounter patients with suboptimal functioning TIPS.