WorldWideScience

Sample records for glycosylated hemoglobin blood

  1. Blood pressure reduction due to hemoglobin glycosylation in type 2 diabetic patients

    Directory of Open Access Journals (Sweden)

    Pedro Cabrales

    2008-08-01

    Full Text Available Pedro Cabrales1, Miguel A Salazar Vázquez2,3, Beatriz Y Salazar Vázquez3,4, Martha Rodríguez-Morán5, Marcos Intaglietta4, Fernando Guerrero-Romero51La Jolla Bioengineering Institute, La Jolla, California, USA; 2Hospital Regional No. 1, of the Mexican Social Security Institute, Victoria de Durango, Dgo. Mexico; 3Faculty of Medicine and Dept. of Physical Chemistry, Universidad Juárez del Estado de Durango, Victoria de Durango, Dgo. Mexico; 4Department of Bioengineering, University of California, San Diego, La Jolla, California, USA; 5Biomedical Research Unit, of the Mexican Social Security Institute, Victoria de Durango, Dgo. MexicoObjective: To test the hypothesis that glycosylation of hemoglobin constitutes a risk factor for hypertension.Methods: A total of 129 relative uniform diabetic subjects (86 women and 42 men were enrolled in a cross-sectional study. Exclusion criteria included alcohol consumption, smoking, ischemic heart disease, stroke, neoplasia, renal, hepatic, and chronic inflammatory disease. Systolic and diastolic pressures were recorded in subsequent days and mean arterial blood pressure (MAP was determined. Hemoglobin glycosylation was measured by determining the percentage glycosylated hemoglobin (HbA1c by means of the automated microparticle enzyme immunoassay test.Results: MAP was found to be independent of the concentration of HbA1c; however, correcting MAP for the variability in hematocrit, to evidence the level of vasoconstriction (or vasodilatation showed that MAP is negatively correlated with the concentration of HbA1c (p for trend <0.05, when patients treated for hypertension are excluded from the analysis. Patients treated for hypertension showed the opposite trend with increasing MAP as HbA1c increased (p for the difference in trends <0.05.Conclusions: Glycosylation per se appears to lead to blood pressure reduction in type 2 diabetic patients untreated for hypertension. Treatment for hypertension may be

  2. Effects of laser acupoint irradiation on blood glucose and glycosylated hemoglobin in type 2 diabetes mellitus

    Science.gov (United States)

    Hui-Hui, Liu; Guo-Xin, Xiong; Li-Ping, Zhang

    2016-06-01

    To investigate the effects of semiconductor laser acupoint irradiation on blood glucose, glycosylated hemoglobin and physical fitness in type 2 diabetes mellitus, 44 cases of type 2 diabetic patients were randomly divided into a control group and a treatment group. All patients in both groups were given a drug treatment. The Hegu, Quchi and Zusanli acupoints of patients in the treatment group were then irradiated daily for 15 d with a 10 MW semiconductor laser. Before and after treatment, patients in both groups underwent a variety of tests and measurements: a two-hour postprandial blood glucose test; a glycosylated hemoglobin test and body mass index (BMI), waist-to-hip ratio (WHR) and body fat percentage (BFP) measurements. The data detected after treatment greatly decreased in the treatment group and was significantly different from that in the control group. It is shown that the acupoint irradiation with a semiconductor laser can improve two-hour postprandial blood glucose, glycosylated hemoglobin and some physical fitness measurements in type 2 diabetes mellitus patients.

  3. COMPARISON OF FRUCTOSAMINE AND GLYCOSYLATED HEMOGLOBIN IN A NON-INSULIN DEPENDENT DIABETIC POPULATION

    Directory of Open Access Journals (Sweden)

    M. Amini

    1999-08-01

    Full Text Available In an attempt to determine the clinical value of frnctosamine assay for monitoring type II diabetic patients, correlation of frnctosamine with glycosylated hemoglobin was studied. 100 patients with type II diabetes mcllitus were compared with 100 normal subjects. Fasting blood glucose, glycosylated hemoglobin, albumin and frnctosamine were measured in alt subjects. In the diabetic patients, a significant correlation was observed between fasting blood glucose and glycosylated hemoglobin (r = 0.64, p < 0.01 and scrum frnctosamine (r = 0.7, P < 0.01. Tlicrc was also a significant correlation between glycosylated hemoglobin and scrum frtictosmine (r = .94, I'<0.01. Frnctosamine, assay can be used as an index of diabetes control.

  4. Quantifying risk of penile prosthesis infection with elevated glycosylated hemoglobin.

    Science.gov (United States)

    Wilson, S K; Carson, C C; Cleves, M A; Delk, J R

    1998-05-01

    Elevation of glycosylated hemoglobin above levels of 11.5 mg.% has been considered a contraindication to penile prosthesis implantation in diabetic patients. We determine the predictive value of glycosylated hemoglobin A1C in penile prosthesis infections in diabetic and nondiabetic patients to confirm or deny this prevalent opinion. We conducted a 2-year prospective study of 389 patients, including 114 diabetics, who underwent 3-piece penile prosthesis implantation. All patients had similar preoperative preparation without regard to diabetic status, control or glycosylated hemoglobin A1C level. Risk of infection was statistically analyzed for diabetics versus nondiabetics, glycosylated hemoglobin A1C values above and below 11.5 mg.%, insulin dependent versus oral medication diabetics, and fasting blood sugars above and below 180 mg.%. Prosthesis infections developed in 10 diabetics (8.7%) and 11 nondiabetics (4.0%). No increased infection rate was observed in diabetics with high fasting sugars or diabetics on insulin. There was no statistically significant increased infection risk with increased levels of glycosylated hemoglobin A1C among all patients or among only the diabetics. In fact, there was no meaningful difference in the median or mean level of glycosylated hemoglobin A1C in the infected and noninfected patients regardless of diabetes. Use of glycosylated hemoglobin A1C values to identify and exclude surgical candidates with increased risk of infections is not proved by this study. Elevation of fasting sugar or insulin dependence also does not increase risk of infection in diabetics undergoing prosthesis implantation.

  5. Study on the relationship between blood levels of growth hormone, glycosylated hemoglobin and micro-vascular nephropathy in patients with diabetes

    International Nuclear Information System (INIS)

    Cai Facheng; Yao Yingfei; Zhang Jinchi

    2005-01-01

    Objective: To evaluate the relationship between blood levels of growth hormone, glycosylated hemoglobin and micro-vascular nephropathy in patients with diabetes. Methods: Blood growth hormone and β 2 -m levels were determined with RIA and GH2 bA 1C , blood glucose were determined with biochemical method in 41 diabetic patients and 32 controls. Results: The blood levels of growth hormone, glycosylated hemoglobin, β 2 -microglobulin and fasting blood glucose in the patients with diabetes well controlled (n=22) were significantly higher than those in controls and levels in patients with diabetes poorly controlled (n=19) were again significantly higher than those in patients with diabetes well controlled (P 2 -microglobulin and fasting blood glucose is very important for early detection of diabetic nephropathy. (authors)

  6. Patterns of glycemic control using glycosylated hemoglobin in diabetics.

    Science.gov (United States)

    Kahlon, Arunpreet Singh; Pathak, Rambha

    2011-07-01

    Till now estimation of blood glucose is the highly effective method for diagnosing diabetes mellitus but it provides a short-term picture of control. More evidence is required to prove that plasma glucose and glycosylated hemoglobin levels together gives a better estimate of glycemic control and compliance with treatment. Indian diabetes risk score (IDRS) is a simplified screening tool for identifying undiagnosed diabetic subjects, requires minimum time, and effort and can help to considerably reduce the costs of screening. To study patterns of glycemic control using glycosylated hemoglobin in diabetic patients. To find out correlation between levels of plasma glucose and glycosylated hemoglobin in diabetics and to calculate IDRS of the study population. A cross sectional study was conducted among 300 known diabetic patients attending outpatient department of a rural medical college in Haryana, India. Following standard procedures and protocols FPG and glycosylated hemoglobin were measured to find out a pattern of glycemic control in them after taking their written and informed consent. A correlation between the levels of glycosylated hemoglobin and fasting blood glucose was also calculated. These patients were made to fill a performa and their demographic and clinical risk factors were noted and based on this, their IDRS was calculated. This was done to validate the IDRS in Indian rural population. Fifty-two percent of the population had fasting plasma glucose level between 125-150 mg/dl, 21% had this level between 151-175 mg/dl. Thirteen percent of the study subjects had HbA1C between 6.5-7.5, more than half (57.3%) had this value between 7.5-8.5, 12% and 18% had values between 8.5-9.5 and 9.5-10.5, respectively. Twelve percent of the participants had HbA1C level higher than 10.5. Correlation of fasting plasma glucose level and HbA1C was also studied and found that correlation coefficient came out to be .311. This correlation was found to be statistically

  7. Patterns of glycemic control using glycosylated hemoglobin in diabetics

    Directory of Open Access Journals (Sweden)

    Arunpreet Singh Kahlon

    2011-01-01

    Full Text Available Aim : Till now estimation of blood glucose is the highly effective method for diagnosing diabetes mellitus but it provides a short-term picture of control. More evidence is required to prove that plasma glucose and glycosylated hemoglobin levels together gives a better estimate of glycemic control and compliance with treatment. Indian diabetes risk score (IDRS is a simplified screening tool for identifying undiagnosed diabetic subjects, requires minimum time, and effort and can help to considerably reduce the costs of screening. Objective : To study patterns of glycemic control using glycosylated hemoglobin in diabetic patients. To find out correlation between levels of plasma glucose and glycosylated hemoglobin in diabetics and to calculate IDRS of the study population. Materials and Methods : A cross sectional study was conducted among 300 known diabetic patients attending outpatient department of a rural medical college in Haryana, India. Following standard procedures and protocols FPG and glycosylated hemoglobin were measured to find out a pattern of glycemic control in them after taking their written and informed consent. A correlation between the levels of glycosylated hemoglobin and fasting blood glucose was also calculated. These patients were made to fill a performa and their demographic and clinical risk factors were noted and based on this, their IDRS was calculated. This was done to validate the IDRS in Indian rural population. Results : Fifty-two percent of the population had fasting plasma glucose level between 125-150 mg/dl, 21% had this level between 151-175 mg/dl. Thirteen percent of the study subjects had HbA1C between 6.5-7.5, more than half (57.3% had this value between 7.5-8.5, 12% and 18% had values between 8.5-9.5 and 9.5-10.5, respectively. Twelve percent of the participants had HbA1C level higher than 10.5. Correlation of fasting plasma glucose level and HbA1C was also studied and found that correlation coefficient came

  8. Fasting serum glucose and glycosylated hemoglobin level in obesity.

    Science.gov (United States)

    Das, R K; Nessa, A; Hossain, M A; Siddiqui, N I; Hussain, M A

    2014-04-01

    Obesity is a condition in which the body fat stores are increased to an extent which impairs health and leads to serious health consequences. The amount of body fat is difficult to measure directly, and is usually determined from an indirect measure - the body mass index (BMI). Increased BMI in obese persons is directly associated with an increase in metabolic disease, such as type 2 diabetes mellitus. This Analytical cross sectional study was undertaken to assess the relation between obesity and glycemic control of body by measuring fasting serum glucose and glycosylated hemoglobin. This study was carried out in the Department of Physiology, Mymensingh Medical College, Mymensingh from 1st July 2011 to 30th June 2012 on 120 equally divided male and female persons within the age range of 25 to 55 years. Age more than 55 years and less than 25 years and diagnosed case of Hypothyroidism, Cushing's syndrome, polycystic ovary, Antipsychotic drug user and regular steroid users were excluded. Non probability purposive type of sampling technique was used for selecting the study subjects. Measurement of body mass index was done as per procedure. Fasting serum glucose was estimated by glucose oxidase method and Glycosylated hemoglobin by Boronate Affinity method. Statistical analysis was done by SPSS (version 17.0). Data were expressed as Mean±SE and statistical significance of difference among the groups were calculated by unpaired student's 't' test and Pearson's correlation coefficient tests were done as applicable. The Mean±SE of fasting serum glucose was significant at 1% level (P value obese group of BMI. There was no significant difference of glycosylated hemoglobin level between control and study groups. But there was positive correlation within each group. Fasting serum glucose also showed a bit stronger positive correlation with BMI. Both obese male and female persons showed higher levels of fasting serum glucose and glycosylated hemoglobin. The observed positive

  9. Glycosylated hemoglobin as a forecast factor of progressing of diabetic nephropathy in patients with diabetes type 1

    Directory of Open Access Journals (Sweden)

    Pertseva N.O.

    2017-12-01

    Full Text Available The aim of the study was to propose a mathematical model for prediction of development of diabetic nephropathy in patients with diabetes mellitus by determining the level of glycosylated hemoglobin - as a factor in the development and progression of diabetic nephropathy. A survey of 136 patients with type 1 diabetes was performed in the endocrinology department of the OSH «Clinic of the Medical Academy», Dnipro in 2016-2017. Clinical laboratory examination included: determination of the level of glycosylated hemoglobin (HbA1c, level of blood creatinine, level of albuminuria. The GFR was calculated by the formula CKD-EPI. The obtained results of the study, using methods of correlation and regression analysis, show a clear correlation between the GFR score in patients with diabetes mellitus and the level of glycosylated hemoglobin. Statistical methods of analysis have shown that the level of glycosylated hemoglobin can be considered as an early predictor of development of diabetic nephropathy. The mathematical equation of prognosis for the onset of diabetic nephropathy can be used to determine the prognosis for the development of diabetic nephropathy in diabetes mellitus patients in clinical practice for the timely inclusion of patients with a high prognostic risk in a group requiring more stringent glycemic control.

  10. 21 CFR 864.7470 - Glycosylated hemoglobin assay.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Glycosylated hemoglobin assay. 864.7470 Section 864.7470 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Kits and Packages § 864.7470...

  11. Marked increase in rat red blood cell membrane protein glycosylation by one-month treatment with a cafeteria diet

    Directory of Open Access Journals (Sweden)

    Laia Oliva

    2015-07-01

    Full Text Available Background and Objectives. Glucose, an aldose, spontaneously reacts with protein amino acids yielding glycosylated proteins. The compounds may reorganize to produce advanced glycosylation products, which regulatory importance is increasingly being recognized. Protein glycosylation is produced without the direct intervention of enzymes and results in the loss of function. Glycosylated plasma albumin, and glycosylated haemoglobin are currently used as index of mean plasma glucose levels, since higher glucose availability results in higher glycosylation rates. In this study we intended to detect the early changes in blood protein glycosylation elicited by an obesogenic diet.Experimental Design. Since albumin is in constant direct contact with plasma glucose, as are the red blood cell (RBC membranes, we analyzed their degree or glycosylation in female and male rats, either fed a standard diet or subjected to a hyper-energetic self-selected cafeteria diet for 30 days. This model produces a small increase in basal glycaemia and a significant increase in body fat, leaving the animals in the initial stages of development of metabolic syndrome. We also measured the degree of glycosylation of hemoglobin, and the concentration of glucose in contact with this protein, that within the RBC. Glycosylation was measured by colorimetric estimation of the hydroxymethylfurfural liberated from glycosyl residues by incubation with oxalate.Results. Plasma glucose was higher in cafeteria diet and in male rats, both independent effects. However, there were no significant differences induced by sex or diet in either hemoglobin or plasma proteins. Purified RBC membranes showed a marked effect of diet: higher glycosylation in cafeteria rats, which was more marked in females (not in controls. In any case, the number of glycosyl residues per molecule were higher in hemoglobin than in plasma proteins (after correction for molecular weight. The detected levels of glucose in

  12. Inhibitory potential of pure isoflavonoids, red clover, and alfalfa extracts on hemoglobin glycosylation

    Directory of Open Access Journals (Sweden)

    Mohsen Hosseini

    2015-03-01

    Full Text Available BACKGROUND: Non-enzymatic glycosylation of hemoglobin is complications of diabetes. Antioxidant system imbalance can result in the emergence of free radicals’ destructive effects in the long-term. Red clover (Trifolium pratense L. and alfalfa (Medicago sativa L. contain isoflavonoids and have antioxidant activity. This experimental study evaluated the inhibitory activity of pure isoflavonoids (daidzein and genistein, red clover and alfalfa extracts on hemoglobin glycosylation. METHODS: This study was performed in Iran. Stock solution of hydroalcoholic extracts of red clover and alfalfa in concentrations of 1 and 10 g/100 ml and stock solution of daidzein and genistein in concentrations of 250 ng, 500 ng, 25 µg and 250 µg/100 ml were prepared as case groups. Control group was without hydroalcoholic extracts of plants and pure isoflavonoids. All experiments were performed in triplicate. Hemoglobin was prepared and antioxidant activities were investigated to estimate degree of nonenzymatic hemoglobin glycosylation. RESULTS: There was no significantly difference between used extracts (extract of red clover and alfalfa and control of the hemoglobin glycosylation but using daidzein (P = 0.046, 0.029 and 0.021, respectively and genistein (P = 0.034, 0.036 and 0.028 significantly inhibited (P < 0.050 this reaction in 25 µg/100 ml, 250 and 500 ng/100 ml concentrations when compared to control. in 25 µg/100 ml, 250 ng and 500 ng/100 ml concentrations percentage of inhibition were 32, 80 and 74.5% respectively with used of daidzein and were 21, 83 and 76% respectively with consumption of genistein. CONCLUSION: According to decrease of glycation of hemoglobin with isoflavonoids, two used plant in this study containing isoflavonoid may be useful on diabetes.   

  13. Comparison of glycosylated hemoglobin (HbA1C levels in patients with chronic periodontitis and healthy controls

    Directory of Open Access Journals (Sweden)

    Padma Rajan

    2013-01-01

    Conclusion: Chronic periodontitis is associated with a slight elevation in glycosylated hemoglobin (lab and chair side kit and that the clinical significance of this difference remains to be determined. This preliminary finding is consistent with earlier reports that chronic periodontitis is associated with elevated blood glucose in adults without diabetes and may increase one′s risk for type-2 diabetes.

  14. Nonenzymatic glycosylation of human hemoglobin at multiple sites

    International Nuclear Information System (INIS)

    Shapiro, R.; McManus, M.; Garrick, L.; McDonald, M.J.; Bunn, H.F.

    1979-01-01

    The most abundant minor hemoglobin component of human hemolysate is Hb A1c, which has glucose bound to the N-terminus of the beta chain by a ketoamine linkage. Hb A1c is formed slowly and continuously throughout the 120 day lifespan of the red cell. It can be synthesized in vitro by incubating purified hemoglobin with 14C-glucose. Other minor components, Hb A1a1 and Hb A1a2 are adducts of sugar phosphates at the N-terminus of the beta chain. Hb A1b contains an unidentified nonphosphorylated sugar at the beta N-terminus. In addition, a significant portion of the major hemoglobin component (Hb Ao) is also glycosylated by a glucose ketoamine linkage at other sites on the molecule, including the N-terminus of the alpha chain and the epsilon-amino group of several lysine residues on both the alpha and the beta chains. The results indicate that the interaction of glucose and hemoglobin is rather nonspecific and suggests that other proteins are modified in a similar fashion

  15. The effects of 2,3-diphosphoglycerate, adenosine triphosphate, and glycosylated hemoglobin on the hemoglobin-oxygen affinity of diabetic patients

    Directory of Open Access Journals (Sweden)

    Castilho E.M.

    2003-01-01

    Full Text Available The position of the oxygen dissociation curve (ODC is modulated by 2,3-diphosphoglycerate (2,3-DPG. Decreases in 2,3-DPG concentration within the red cell shift the curve to the left, whereas increases in concentration cause a shift to the right of the ODC. Some earlier studies on diabetic patients have reported that insulin treatment may reduce the red cell concentrations of 2,3-DPG, causing a shift of the ODC to the left, but the reports are contradictory. Three groups were compared in the present study: 1 nondiabetic control individuals (N = 19; 2 insulin-dependent diabetes mellitus (IDDM patients (on insulin treatment (N = 19; 3 non-insulin-dependent diabetes mellitus (NIDDM patients using oral hypoglycemic agents and no insulin treatment (N = 22. The overall position of the ODC was the same for the three groups despite an increase of the glycosylated hemoglobin fraction that was expected to shift the ODC to the left in both groups of diabetic patients (HbA1c: control, 4.6%; IDDM, 10.5%; NIDDM, 9.0%. In IDDM patients, the effect of the glycosylated hemoglobin fraction on the position of the ODC appeared to be counterbalanced by small though statistically significant increases in 2,3-DPG concentration from 2.05 (control to 2.45 µmol/ml blood (IDDM. Though not statistically significant, an increase of 2,3-DPG also occurred in NIDDM patients, while red cell ATP levels were the same for all groups. The positions of the ODC were the same for control subjects, IDDM and NIDDM patients. Thus, the PO2 at 50% hemoglobin-oxygen saturation was 26.8, 28.2 and 28.5 mmHg for control, IDDM and NIDDM, respectively. In conclusion, our data question the idea of adverse side effects of insulin treatment on oxygen transport. In other words, the shift to the left reported by others to be caused by insulin treatment was not detected.

  16. The effects of 2,3-diphosphoglycerate, adenosine triphosphate, and glycosylated hemoglobin on the hemoglobin-oxygen affinity of diabetic patients.

    Science.gov (United States)

    Castilho, E M; Glass, M L; Manço, J C

    2003-06-01

    The position of the oxygen dissociation curve (ODC) is modulated by 2,3-diphosphoglycerate (2,3-DPG). Decreases in 2,3-DPG concentration within the red cell shift the curve to the left, whereas increases in concentration cause a shift to the right of the ODC. Some earlier studies on diabetic patients have reported that insulin treatment may reduce the red cell concentrations of 2,3-DPG, causing a shift of the ODC to the left, but the reports are contradictory. Three groups were compared in the present study: 1) nondiabetic control individuals (N = 19); 2) insulin-dependent diabetes mellitus (IDDM) patients (on insulin treatment) (N = 19); 3) non-insulin-dependent diabetes mellitus (NIDDM) patients using oral hypoglycemic agents and no insulin treatment (N = 22). The overall position of the ODC was the same for the three groups despite an increase of the glycosylated hemoglobin fraction that was expected to shift the ODC to the left in both groups of diabetic patients (HbA1c: control, 4.6%; IDDM, 10.5%; NIDDM, 9.0%). In IDDM patients, the effect of the glycosylated hemoglobin fraction on the position of the ODC appeared to be counterbalanced by small though statistically significant increases in 2,3-DPG concentration from 2.05 (control) to 2.45 mol/ml blood (IDDM). Though not statistically significant, an increase of 2,3-DPG also occurred in NIDDM patients, while red cell ATP levels were the same for all groups. The positions of the ODC were the same for control subjects, IDDM and NIDDM patients. Thus, the PO2 at 50% hemoglobin-oxygen saturation was 26.8, 28.2 and 28.5 mmHg for control, IDDM and NIDDM, respectively. In conclusion, our data question the idea of adverse side effects of insulin treatment on oxygen transport. In other words, the shift to the left reported by others to be caused by insulin treatment was not detected.

  17. Validation and modification of dried blood spot-based glycosylated hemoglobin assay for the longitudinal aging study in India.

    Science.gov (United States)

    Hu, Peifeng; Edenfield, Michael; Potter, Alan; Kale, Varsha; Risbud, Arun; Williams, Sharon; Lee, Jinkook; Bloom, David E; Crimmins, Eileen; Seeman, Teresa

    2015-01-01

    This study aims to validate a modified dried blood spot (DBS)-based glycosylated hemoglobin (HbA1c) assay protocol, after a pretest in India showed poor correlation between the original DBS-based protocol and venous results. The original protocol was tested on different chemistry analyzers and then simplified at the University of Washington (UW). A second pretest was conducted in India to validate the modified assay protocol, using 44 quality control specimens. Data from UW indicated that, using the original protocol, the correlation coefficients between DBS and venous results were above 0.98 on both Bio-Rad and Olympus chemistry analyzers. The protocol worked equally well on filter paper, with or without pre-treatment, and when the recommended amount of blood spot material, or less, was used. A second pretest of the modified protocol confirmed that DBS-based levels from both Olympus and Roche chemistry analyzers were well correlated with DBS results from UW (correlation coefficients were above 0.96), as well as with venous values (correlation coefficients were above 0.94). The DBS-based HbA1c values are highly correlated with venous results. The pre-treatment of filter paper does not appear to be necessary. The poor results from the first pretest are probably due to factors unrelated to the protocol, such as problems with the chemistry analyzer or assay reagents. © 2015 Wiley Periodicals, Inc.

  18. [Effect of high-intensity interval training on the reduction of glycosylated hemoglobin in type-2 diabetic adult patients].

    Science.gov (United States)

    Aguilera Eguía, Raúl Alberto; Russell Guzmán, Javier Antonio; Soto Muñoz, Marcelo Enrique; Villegas González, Bastián Eduardo; Poblete Aro, Carlos Emilio; Ibacache Palma, Alejandro

    2015-03-05

    Type 2 diabetes mellitus is one of the major non-communicable chronic diseases in the world. Its prevalence in Chile is significant, and complications associated with this disease involve great costs, which is why prevention and treatment of this condition are essential. Physical exercise is an effective means for prevention and treatment of type 2 diabetes mellitus. The emergence of new forms of physical training, such as "high intensity interval training", presents novel therapeutic alternatives for patients and health care professionals. To assess the validity and applicability of the results regarding the effectiveness of high intensity interval training in reducing glycosylated hemoglobin in adult patients with type 2 diabetes mellitus and answer the following question: In subjects with type 2 diabetes, can the method of high intensity interval training compared to moderate intensity exercise decrease glycosylated hemoglobin? We performed a critical analysis of the article "Feasibility and preliminary effectiveness of high intensity interval training in type 2 diabetes". We found no significant differences in the amount of glycosylated hemoglobin between groups of high intensity interval training and moderate-intensity exercise upon completion of the study (p>0.05). In adult patients with type 2 diabetes mellitus, high intensity interval training does not significantly improve glycosylated hemoglobin levels. Despite this, the high intensity interval training method shows as much improvement in body composition and physical condition as the moderate intensity exercise program.

  19. Mortality in Individuals Aged 80 and Older with Type 2 Diabetes Mellitus in Relation to Glycosylated Hemoglobin, Blood Pressure, and Total Cholesterol.

    Science.gov (United States)

    Hamada, Shota; Gulliford, Martin C

    2016-07-01

    To evaluate whether low glycosylated hemoglobin (HbA1c), blood pressure (BP), and total cholesterol (TC) are associated with lower risk of all-cause mortality in very old individuals with type 2 diabetes mellitus. Population-based cohort study. Primary care database in the United Kingdom. Individuals aged 80 and older with type 2 diabetes mellitus (N = 25,966). Associations between baseline HbA1c, BP, and TC and all-cause mortality were evaluated in Cox proportional hazards models. Analyses were adjusted for sex, age, duration of diabetes mellitus, lifestyle variables, HbA1c, BP, TC, comorbidities, prescribing of antidiabetic and cardiovascular drugs, and participants' general practice. There were 4,490 deaths during follow-up (median 2.0 years; mortality 104.7 per 1,000 person-years). Mortality in participants with low (type 2 diabetes mellitus. Further research is required to understand these associations and to identify optimal treatment targets in this population. © 2016 The Authors. The Journal of the American Geriatrics Society published by Wiley Periodicals, Inc. on behalf of The American Geriatrics Society.

  20. Study on the relationship between blood levels of glycated hemoglobin (HbA1c) and micro-vascular nephropathy in patients with type 2 diabetes

    International Nuclear Information System (INIS)

    Luo Rong; Li Zhuocheng; Yan Dewen

    2004-01-01

    Objective: To evaluate the relationship between blood levels of glycated hemoglobin and microvascular nephropathy in patients with type diabetes. Methods: Blood Glycosylated hemoglobin levels were determined with affinity chromatography and 24 hour urinary microalbumin (m-Alb), β 2 microglobin (β 2 -m) quantified with RIA in 76 patients and 30 controls. Results: With glycated hemoglobin within normal range, there were no differences between the amounts of patients' urinary protein contents and those in controls (P>0.05). With higher blood glycated hemoglobin levels, significant differences could be observed (P 2 microglobin. Differences among the 24 hour urinary quantities of mAlb and β 2 -m in the three groups of patients (divided according to the HbA1c levels, namely 9.0%) were also significant (P 2 microglobin is very important for early detection of diabetic nephropathy

  1. Relationship between Sucralose Consumption and Serum Concentration of Glycosylated Hemoglobin in People with Type 2 Diabetes Mellitus without Complications

    Directory of Open Access Journals (Sweden)

    María del Carmen Cortés-López

    2017-11-01

    Full Text Available People who live with diabetes consume sucralose to control their blood glucose, but there is a controversy about this topic. To evaluate the relationship between sucralose consumption and serum concentration of glycosylated hemoglobin in people with Type 2 Diabetes Mellitus without complications. Cross-sectional study. Universe of 27 214 people with Type 2 Diabetes Mellitus without complications, users of a primary care unit from the Instituto Mexicano del Seguro Social in the state of Jalisco, Mexico. Simple probabilistic sample, n = 194 (p = 0,05. Propositive sampling. Selection criteria: adults of any gender and education level who agreed to participate. Variables: sociodemographic, anthropometric, clinical and dietary. Data collection instruments: Sociodemographic questionnaire, Tanita Fitscan© 585 scale, Tanita Fitscan© HR-200 stadiometer, Body Flex© tape-measure, Slim Guide© plicometer, Afinion© AS100 analyzer, and Frequency of Food Consumption Questionnaire. Information sources: clinical files and Mexican System of Equivalent Foods. Analysis: descriptive and inferential statistics (p ≤ 0,05. 194 people. Mean age 60,23 ± 11,16, interval 28-93 years. 56,2% females and 43,8% males. Difference between glycosilated hemoglobin means: sucralose consumers 7,5% ± 1,7%, no sucralose consumers 8,1% ± 2,1% (p < 0,01. Association force “sucralose consumption/high glycosilated hemoglobin concentration” OR = 1,42 (CI95% 0,63, 3,21. Lineal correlation “quarterly sucralose consumption/serum concentration of glycosylated hemoglobin” ρ = -0,754 (R2 = 0,0057, p = 0,333. This results were partially consistent to the pre-existing literature. Studies with representative stratified samples and control of dietary variables are required for better results.

  2. Association between elevated pre-operative glycosylated hemoglobin and post-operative infections after non-emergent surgery

    OpenAIRE

    Blankush, Joseph M.; Leitman, I. Michael; Soleiman, Aron; Tran, Trung

    2016-01-01

    Background: A chronic state of impaired glucose metabolism affects multiple components of the immune system, possibly leading to an increased incidence of post-operative infections. Such infections increase morbidity, length of stay, and overall cost. This study evaluates the correlation between elevated pre-operative glycosylated hemoglobin (HbA1c) and post-operative infections. Study design: Adult patients undergoing non-emergent procedures across all surgical subspecialties from January...

  3. Algunos aspectos de actualidad sobre la hemoglobina glucosilada y sus aplicaciones Some updated features on glycosylated hemoglobin and its applications

    Directory of Open Access Journals (Sweden)

    Eduardo Álvarez Seijas

    2009-12-01

    Full Text Available La hemoglobina glucosilada es un examen que mide la cantidad de hemoglobina que se glucosila en la sangre, y brinda un buen estimado del control glucémico durante los últimos 3 meses en personas prediabéticas y diabéticas, por lo que habitualmente se utiliza en el monitoreo de esta enfermedad. Un comité de expertos en diabetes, formado en el año 2008, analizó la relación entre la exposición glucémica a largo plazo y las complicaciones crónicas de la diabetes mellitus, y recomienda esta prueba como una nueva herramienta diagnóstica para esta enfermedad. Por la importancia de este tema para la práctica médica, se realiza una descripción actualizada de los antecedentes, metodología, interpretaciones y usos de este examen.Glycosylated hemoglobin is an examination measuring the amount of hemoglobin glycosylated in blood and gave a good estimated of the glycemia control during the last three months in prediabetic and diabetic persons, thus, usually it is used in monitoring of this disease. An expert committee on diabetes created in 2008, analyzed the relationship between the long-term glycemia exposition and the chronic complications of diabetes mellitus, and recommended this type of test as a new diagnostic tool for this disease. Due to the significance of this topic for medical practice, an updated description of backgrounds, methodology, interpretation and uses of this examination is performed.

  4. Relationship between changes in hemoglobin glycosilated and improvement of body composition in patients with morbid obesity after tubular laparoscopic gastrectomy.

    Science.gov (United States)

    Gallart-Aragón, Tania; Fernández-Lao, Carolina; Cózar-Ibañez, Antonio; Cantarero-Villanueva, Irene; Cambil-Martín, Jacobo; Jiménez Ríos, José Antonio; Arroyo-Morales, Manuel

    2017-12-29

    The objective of our study is to analyze the possible relationship between changes in glycemic profile and body composition parameters in morbid obesity patients after tubular laparoscopic gastrectomy. A prospective observational cohort study with 69 patients was performed. The variables analyzed were body weight, blood glucose, hemoglobin, glycosylated, high density lipoprotein, low density lipoprotein, triglycerides, and waist and hip circumference. An analysis of variance of repeated measurements (ANOVA) and a correlation analysis through the Pearson test were carried out. A significant reduction in weight (p<.001 after surgery) and in glycosylated hemoglobin (p<.036) and waist hip (p<.001) were found at 6 months after surgery. There was no significant difference in the rest of the variables studied. In correlation analysis, a significant positive correlation was found between the change in concentration of hemoglobin glycosylated and hip circumference (p=.047; r=0.237), the smaller the hip circumference, the lower the concentration of glycosylated hemoglobin. Tubular laparoscopic gastrectomy is an effective technique for the treatment of morbidly obese patients with type 2 diabetes mellitus. The reduction in the perimeter of hip is related to glycosylated hemoglobin reduction 6 months after intervention. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  5. A retrospective cohort study of blood hemoglobin levels in blood donors and competitive rowers

    DEFF Research Database (Denmark)

    Johansson, P.I.; Ullum, H.; Jensen, K.

    2009-01-01

    To investigate the distribution of blood hemoglobin levels in healthy blood donors and elite athletes, a retrospective cohort study from 2001 to 2005 of candidate blood donors and elite rowers in Denmark was performed. Eighty-five thousand eight hundred and forty-six blood donors were identified.......3% of the females demonstrated values above the recommended limit for athletic competition. Thus, the prevalence of a high hemoglobin value was greater in the rowers, of both gender, than in the candidate blood donors (Pblood are seen regularly in normal...... (36 962 males), and 3.9% of the males had a blood hemoglobin above 10.5 mM, equalling a hematocrit of 51% and, 1.6% of the females had hemoglobin above 9.7 mM, corresponding to a hematocrit above 47%. One thousand four hundred and six rowers (1116 males) were investigated and 10.4% of the males and 8...

  6. A microfluidic approach for hemoglobin detection in whole blood

    Directory of Open Access Journals (Sweden)

    Nikita Taparia

    2017-10-01

    Full Text Available Diagnosis of anemia relies on the detection of hemoglobin levels in a blood sample. Conventional blood analyzers are not readily available in most low-resource regions where anemia is prevalent, so detection methods that are low-cost and point-of-care are needed. Here, we present a microfluidic approach to measure hemoglobin concentration in a sample of whole blood. Unlike conventional approaches, our microfluidic approach does not require hemolysis. We detect the level of hemoglobin in a blood sample optically by illuminating the blood in a microfluidic channel at a peak wavelength of 540 nm and measuring its absorbance using a CMOS sensor coupled with a lens to magnify the image onto the detector. We compare measurements in microchannels with channel heights of 50 and 115 μm and found the channel with the 50 μm height provided a better range of detection. Since we use whole blood and not lysed blood, we fit our data to an absorption model that includes optical scattering in order to obtain a calibration curve for our system. Based on this calibration curve and data collected, we can measure hemoglobin concentration within 1 g/dL for severe cases of anemia. In addition, we measured optical density for blood flowing at a shear rate of 500 s-1 and observed it did not affect the nonlinear model. With this method, we provide an approach that uses microfluidic detection of hemoglobin levels that can be integrated with other microfluidic approaches for blood analysis.

  7. A microfluidic approach for hemoglobin detection in whole blood

    Science.gov (United States)

    Taparia, Nikita; Platten, Kimsey C.; Anderson, Kristin B.; Sniadecki, Nathan J.

    2017-10-01

    Diagnosis of anemia relies on the detection of hemoglobin levels in a blood sample. Conventional blood analyzers are not readily available in most low-resource regions where anemia is prevalent, so detection methods that are low-cost and point-of-care are needed. Here, we present a microfluidic approach to measure hemoglobin concentration in a sample of whole blood. Unlike conventional approaches, our microfluidic approach does not require hemolysis. We detect the level of hemoglobin in a blood sample optically by illuminating the blood in a microfluidic channel at a peak wavelength of 540 nm and measuring its absorbance using a CMOS sensor coupled with a lens to magnify the image onto the detector. We compare measurements in microchannels with channel heights of 50 and 115 μm and found the channel with the 50 μm height provided a better range of detection. Since we use whole blood and not lysed blood, we fit our data to an absorption model that includes optical scattering in order to obtain a calibration curve for our system. Based on this calibration curve and data collected, we can measure hemoglobin concentration within 1 g/dL for severe cases of anemia. In addition, we measured optical density for blood flowing at a shear rate of 500 s-1 and observed it did not affect the nonlinear model. With this method, we provide an approach that uses microfluidic detection of hemoglobin levels that can be integrated with other microfluidic approaches for blood analysis.

  8. Thalassemia and Hemoglobin E in Southern Thai Blood Donors

    OpenAIRE

    Nuinoon, Manit; Kruachan, Kwanta; Sengking, Warachaya; Horpet, Dararat; Sungyuan, Ubol

    2014-01-01

    Thalassemia and hemoglobin E (Hb E) are common in Thailand. Individuals with thalassemia trait usually have a normal hemoglobin concentration or mild anemia. Therefore, thalassemic individuals who have minimum acceptable Hb level may be accepted as blood donors. This study was aimed at determining the frequency of α-thalassemia 1 trait, β-thalassemia trait, and Hb E-related syndromes in Southern Thai blood donors. One hundred and sixteen voluntary blood donors, Southern Thailand origin, were ...

  9. Hemoglobin Function in Stored Blood.

    Science.gov (United States)

    1974-08-01

    States during 1973. Several advantages over ACA) are important. Blood stored in CPD maintains higher ./ levels of 2,3-DPG (2,3- diphosphoglycerate ) and a...survival and ATP levels in stored blood is explained by the several functions of ATP which are necessary for cell viability. However, ATP levels do...not correlate with oxygen affinity during storage. Levels of 2,3-DPG determine oxygen affinity and thus hemoglobin function. (12,13) When normal levels

  10. The relationship between vegetables and fruits intake and glycosylated hemoglobin values, lipids profiles and nitrogen status in type II inactive diabetic patients

    Directory of Open Access Journals (Sweden)

    Marjan Tabesh

    2013-01-01

    Conclusions : Intake of vegetables and fruits may reduce the glycosylated hemoglobin, therefore choosing the appropriate diet with high fruits and vegetables may help to develop antioxidant defense and reduce the HbA1C in diabetic patients but it did not have any impact on lipids profiles, BUN/creatinine and urine protein 24 h.

  11. Blood hemoglobin level and treatment outcome of early breast cancer

    International Nuclear Information System (INIS)

    Henke, M.; Sindlinger, F.; Ikenberg, H.; Gerds, T.; Schumacher, M.

    2004-01-01

    Background and purpose: to determine whether the blood hemoglobin concentration correlates with the prognosis of patients with early breast cancer and, if so, whether this is restricted to treatment modality. Patients and methods: data were collected retrospectively from patients with early breast cancer (T1,2 NO-2 MO) who underwent either breast-conserving surgery followed by adjuvant radiotherapy (BCS-RT; n = 96) or a modified radical mastectomy (MRM; n = 194). The effect of preoperative blood hemoglobin level, nodal status, histological grading and hormone receptor status on disease-free survival was determined for both treatment modalities using a cox regression model and visualized by kaplan-meier plots. Results: the blood hemoglobin concentration significantly correlated with disease-free survival of patients receiving BCS-RT (relative risk [RR]: 0.67 per g/dl; p = 0.007). This was independent of other known risk factors for breast cancer patients, as determined by multivariate analysis. By contrast, the blood hemoglobin level had no prognostic significance when patients were treated with MRM. Conclusion: blood hemoglobin concentration seems to affect the prognosis of patients with early breast cancer when a treatment schedule that includes radiotherapy is applied. Reduced radiosensitivity due to diminished tumor oxygenation may be the underlying cause. Confirmative trials and studies intended to elucidate the underlying mechanism are warranted. (orig.)

  12. Predictors of hemoglobin in Danish blood donors

    DEFF Research Database (Denmark)

    Kotzé, Sebastian R; Pedersen, Ole B; Petersen, Mikkel S

    2015-01-01

    BACKGROUND: It is well known that blood donors are at increased risk of iron deficiency and subsequent development of iron deficiency anemia. We aimed to investigate the effect of factors influencing hemoglobin (Hb) levels. STUDY DESIGN AND METHODS: Initiated in 2010, the Danish Blood Donor Study...

  13. Respiratory properties of blood and hemoglobin solutions from the piranha

    DEFF Research Database (Denmark)

    Wood, S.C.; Weber, Roy E.; Powers, D.

    1979-01-01

    1. Respiratory properties of piranha blood are distinguished from those of other fish primarily by the high CO2 buffering capacity (?HCO3/-?pH= 19.6mmol/l for oxygenated blood and 39.1 mmol/l for deoxygenated blood). 2. The concentration of nucleoside triphosphates (NTP) and the half-saturation t......) lowered the oxygen affinity of purified hemoglobin solutions, accounting for the size-dependent correlation ofP50 and NTP concentration in whole blood. 5. While similar in concentration in red cells, GTP is more potent than ATP as an allosteric modifier of hemoglobin function....

  14. Hemoglobin levels and blood transfusion in patients with sepsis in Internal Medicine Departments.

    Science.gov (United States)

    Muady, Gassan Fuad; Bitterman, Haim; Laor, Arie; Vardi, Moshe; Urin, Vitally; Ghanem-Zoubi, Nesrin

    2016-10-13

    Acute reduction in hemoglobin levels is frequently seen during sepsis. Previous studies have focused on the management of anemia in patients with septic shock admitted to intensive care units (ICU's), including aggressive blood transfusion aiming to enhance tissue oxygenation. To study the changes in hemoglobin concentrations during the first week of sepsis in the setting of Internal Medicine (IM) units, and their correlation to survival. Observational prospective study. We recorded hemoglobin values upon admission and throughout the first week of hospital stay in a consecutive cohort of septic patients admitted to IM units at a community hospital, the patients were enrolled into a prospective registry. Data on blood transfusions was also collected, we examined the correlation between hemoglobin concentrations during the first week of sepsis and survival, the effect of blood transfusion was also assessed. Eight hundred and fifteen patients (815) with sepsis were enrolled between February 2008 to January 2009. More than 20 % of them had hemoglobin levels less than 10g/dL on admission, a rate that was doubled during the first week of sepsis. Overall, 68 (8.3 %) received blood transfusions, 14 of them (20.6 %) due to bleeding. Typically, blood transfusion was given to older patients with a higher rate of malignancy and lower hemoglobin levels. While hemoglobin concentration on admission had strong correlation with in-hospital mortality (O.R-0.83 [95 % C.I. 0.74-0.92], blood transfusion was not found to be an independent predicting factor for mortality. Anemia is very common in sepsis. While hemoglobin level on admission exhibit independent correlation with survival, blood transfusion do not.

  15. Study of LAXS Profile of Hemoglobin from Irradiated Blood

    International Nuclear Information System (INIS)

    Selim, N.S.; Desouky, O.S.; Elshemey, W.M.

    2006-01-01

    The present work aims to move a step forward towards a deeper understanding of the scattering of x-ray, from lyophilized biological samples. Comparative study has been performed using low angle x-ray scattering (LAXS) and UV-visible spectrophotometry for monitoring the dose response characteristics of the hemoglobin molecule of irradiated blood. Blood samples were exposed to gamma rays, at doses ranging from 5 up to 100 Gy. Diluted hemoglobin solution was scanned in the UV-visible range (200-700 nm), and lyophilized hemoglobin was prepared for LAXS measurement. The radiation-induced changes in the hemoglobin structure have been evaluated. The LAXS profile of hemoglobin molecule is characterized by the presence of 2 peaks in the forward direction of scattering. These peaks were found to be sensitive to the variations in the molecular structure of a given sample. The obtained results suggest that the 1st peak, recorded at 4.65O (equivalent to momentum transfer, x= 0.526 nm-1), is sensitive to the tertiary and quaternary structure of the globin part, while the major peak, recorded at 10.5O (equivalent to momentum transfer, x= 1.189 nm-1), appeared to be related to its primary and secondary structure

  16. Prognostic value of blood glucose in emergency room and glycosylated hemoglobin in patients who have suffered an acute cerebro-vascular event.

    Science.gov (United States)

    Ernaga Lorea, Ander; Hernández Morhain, María Cecilia; Ollero García-Agulló, María Dolores; Martínez de Esteban, Juan Pablo; Iriarte Beroiz, Ana; Gállego Culleré, Jaime

    2017-07-07

    Stress hyperglycemia has been associated with a worse prognosis in patients hospitalized in critical care units. The aim of this study is to evaluate the impact of blood glucose and glycosylated hemoglobin (HbA1c) levels on the mortality of patients suffering a acute cerebro-vascular event, and to determine if this relationship depends on the presence of diabetes. A retrospective analysis of 255 patients admitted to the ER for stroke was performed. Venous plasma glucose levels in the emergency room and HbA1c levels within the first 48hours were analyzed. The presence of diabetes was defined in terms of the patients' medical history, as well as their levels of fasting plasma glucose and HbA1c. Mortality was assessed within the first 30 months after the onset of the acute event. 28.2% of patients had diabetes. Higher mortality was observed in patients who had been admitted with plasma glucose levels≥140mg/dl (hazard ratio [HR]=2.22, 95% CI: 1.18-4.16, P=.013) after adjusting for various factors. This relationship was not confirmed in diabetic patients (HR=2.20, 95% CI: 0.66-7.40, P=.201) and was in non-diabetics (HR=2.55, 95% CI: 1.11-5.85, P=.027). In diabetics, HbA1c≥7% was not associated with poor prognosis (HR=0.68, 95% CI: 0.23-1.98, P=.475), whereas non-diabetics with admission levels of HbA1c falling within the pre-diabetes range (5.7% -6.4%) had a higher mortality (HR=2.62, 95% CI: 1.01-6.79, P=.048). Admission hyperglycemia is associated with a worse prognosis in patients without diabetes admitted for stroke, but this relationship was not seen in diabetics. In non-diabetic patients, HbA1c levels in the pre-diabetes range is associated with higher mortality. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  17. Effect of Cola acuminate on Blood Glucose and Glycosylated ...

    African Journals Online (AJOL)

    The levels of blood glucose and glycosylated haemoglobin (GHB) were studied in 42 Wistar rats divided into three groups; controls, group A and group B. Control rats consumed only feeds, group A consumed 0.04g of Cola acuminate, while group B consumed 0.08g of Cola acuminate mixed with their feeds daily for six ...

  18. Operative time, blood loss, hemoglobin drop, blood transfusion, and hospital stay in orthognathic surgery.

    Science.gov (United States)

    Salma, Ra'ed Ghaleb; Al-Shammari, Fahad Mohammed; Al-Garni, Bishi Abdullah; Al-Qarzaee, Mohammed Abdullah

    2017-06-01

    This study was conducted to evaluate the operative time, blood loss, hemoglobin drop, blood transfusion, and length of hospital stay in orthognathic surgery. A 10-year retrospective analysis was performed on patients who underwent bilateral sagittal split osteotomy (with or without genioplasty), Le Fort I osteotomy (with or without genioplasty), or any combination of these procedures. A total of 271 patients were included. The age range was 17 to 49 years, with a mean age of 24.13 ± 4.51 years. Approximately 62% of patients underwent double-jaw surgery. The most common procedure was bilateral sagittal split with Le Fort I (37%). The average operative time was 3.96 ± 1.25 h. The mean estimated blood loss was 345.2 ± 149.74 mL. Approximately 9% of patients received intraoperative blood transfusion. The mean hemoglobin drop in the non-transfusion cases was 2.38 ± 0.89 g/dL. The mean postoperative hospital stay was 1.85 ± 0.83 days. Only one patient was admitted to the ICU for one night. In orthognathic surgery, blood loss is relatively minor, blood transfusion is frequent, and ICU admission is unlikely. Operative time, blood loss, blood transfusion, and the complexity of the surgical procedure can significantly increase the length of hospital stay. Males may bleed more than females in orthognathic surgery. Hemoglobin drop can be overestimated due to hemodilution in orthognathic surgery, which may influence the decision to use blood transfusion.

  19. Cotransplantation of Mesenchymal Stem Cells and Immature Dendritic Cells Potentiates the Blood Glucose Control of Islet Allografts

    Directory of Open Access Journals (Sweden)

    Guanghui Long

    2017-01-01

    Full Text Available Background. Transplantation of islets is a promising alternative to treat type 1 diabetes (T1D, but graft rejection is the major obstacle to its application in clinical practice. We evaluated the effects of mesenchymal stem cells (MSCs and immature dendritic cells (imDCs on islet transplantation in diabetic model. Methods. The streptozotocin T1D model was established in BABL/c mice. Rat islets were isolated and identified with dithizone (DTZ staining. MSCs and imDCs were isolated from bone marrow of syngenic mice. Islets, alone or along with MSCs and/or imDCs, were transplanted to the left kidney capsule of diabetic mice. The blood glucose levels and glycosylated hemoglobin levels after transplantation were monitored. Results. Cotransplantation significantly decreased blood glucose and glycosylated hemoglobin levels in the diabetes mice. Transplantation of 200 islets + 2 × 105 MSCs + 2 × 105 imDCs could not only restore normal blood glucose levels, but also significantly prolong graft survival for 12.6±3.48 days. Conclusions. Cotransplantation of allogenic islets with imDCs and/or MSCs can significantly promote graft survival, reverse hyperglycemia, and effectively control the glycosylated hemoglobin levels.

  20. Raman Tweezers as a Diagnostic Tool of Hemoglobin-Related Blood Disorders

    Directory of Open Access Journals (Sweden)

    Giulia Rusciano

    2008-12-01

    Full Text Available This review presents the development of a Raman Tweezers system for detecting hemoglobin-related blood disorders at a single cell level. The study demonstrates that the molecular fingerprint insight provided by Raman analysis holds great promise for distinguishing between healthy and diseased cells in the field of biomedicine. Herein a Raman Tweezers system has been applied to investigate the effects of thalassemia, a blood disease quite diffuse in the Mediterranean Sea region. By resonant excitation of hemoglobin Raman bands, we examined the oxygenation capability of normal, alpha- and beta-thalassemic erythrocytes. A reduction of this fundamental red blood cell function, particularly severe for beta-thalassemia, has been found. Raman spectroscopy was also used to draw hemoglobin distribution inside single erythrocytes; the results confirmed the characteristic anomaly (target shape, occurring in thalassemia and some other blood disorders. The success of resonance Raman spectroscopy for thalassemia detection reported in this review provide an interesting starting point to explore the application of a Raman Tweezers system in the analysis of several blood disorders.

  1. [Diagnostic agreement between two glycosylated a1b hemoglobin methods in Primary Care].

    Science.gov (United States)

    Villar-del-Campo, M C; Rodríguez-Caravaca, G; Gil-Yonte, P; Cidoncha-Calderón, E; García-Cruces Méndez, J; Donnay-Pérez, S

    2014-01-01

    Several methods are available for measuring glycosylated A1c hemoglobin (HbA1c), all rapid methods for point of care use in a clinical or laboratory setting. This study attempts to compare the diagnostic agreement between two methods for detection of HbA1c. A descriptive cross-sectional study of diagnostic agreement was carried out in the Los Carmenes Health Centre. Two groups of patients -with and without type 2 diabetes- were consecutively included. A method for point-of-care use in a Primary Care Clinic setting (DCA(TM) Systems Siemens(®)) was compared with a laboratory test (chromatographic analysis). An analysis was made of the mean concentration of HbA1c, the agreement between methods, using the intra-class correlation coefficient (CCLA1) and the Bland-Altman method. A total of 102 patients were included, 62 diabetic (60.8%) and 40 non-diabetic (39.2%). The overall mean HbA1c was 6.46% (SD=0.88) in the analysis using capillary blood in the clinic with the DCA™ system, and 6.44% (SD=0.86) using the laboratory test (P>.05). The degree of agreement between the two tests was 0.975 (95% CI: 0.963-0.983). The mean of the differences between the results of the two assessed tests was 0.024 (SD=0.27). The percentage of points outside the limits of optimal agreement, as defined in the Bland-Altman graph, was 2.5%. Diagnostic agreement between a method for point-of-care use in a Primary Health Care Clinic and a laboratory test was very high. Detection at the point-of-care allows a quick and simple assessment of HbA1c. Copyright © 2013 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España. All rights reserved.

  2. Influence of peripheral blood hemoglobin concentration on the result of radiotherapy for nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    He Beiwa; Zhang Guofen; Zhao Yutian; Wang Zhenwu; Xu Min; Hu Yulin

    2002-01-01

    Objective: To determine the influence of peripheral blood hemoglobin concentration on the radiotherapy result of nasopharyngeal carcinoma (NPC). Methods: From January 1989 to December 1998, 304 patients with pathologically confirmed NPC received radical radiation. There were 209 males and 95 females. The ages ranged from 16 to 77 years with a median of 42. All patients were irradiated by 60 Co or 6 MV external beam with a total dose of 64 - 76 Gy for the primary tumor and 46 - 77 Gy for the cervical lymph nodes. The peripheral blood hemoglobin concentration for all patients was measured before, during and after radiotherapy. These patients were divided into three groups according to the peripheral blood hemoglobin concentration before radiotherapy: anemia ( 160 g/L), and into two groups according to the change in the peripheral blood hemoglobin concentration during radiotherapy as increased and decreased groups. Results: All patients were followed with a follow-up rate of 90.5%. The peripheral blood hemoglobin concentration had a significant effect on the survival of NPC patients. Its decrease or increase during radiotherapy affected the survival and local control rates of NPC patients. Conclusions: The change of peripheral hemoglobin concentration affecting the oxygen content in the blood, can influence the local control and survival rates of NPC patients. Increase results in higher survival

  3. Prediction models for hemoglobin deferral in whole blood donors

    NARCIS (Netherlands)

    Baart, A.M.

    2013-01-01

    Each year, a relevant proportion of the invited blood donors is eventually deferred from donation because of low hemoglobin (Hb) levels. Deferrals are meant to protect donors from developing iron deficiency anemia after a blood donation, however, they may increase the risk of donor lapse, even

  4. Improvement of Glycosylated Hemoglobin in Patients with Type 2 Diabetes Mellitus under Insulin Treatment by Reimbursement for Self-Monitoring of Blood Glucose

    Directory of Open Access Journals (Sweden)

    Young Shin Song

    2017-09-01

    Full Text Available BackgroundIn Korea, the costs associated with self-monitoring of blood glucose (SMBG for patients with type 2 diabetes mellitus (T2DM under insulin treatment have been reimbursed since November 2015. We investigated whether this new reimbursement program for SMBG has improved the glycemic control in the beneficiaries of this policy.MethodsAmong all adult T2DM patients with ≥3 months of reimbursement (n=854, subjects without any changes in anti-hyperglycemic agents during the study period were selected. The improvement of glycosylated hemoglobin (HbA1c was defined as an absolute reduction in HbA1c ≥0.6% or an HbA1c level at follow-up <7%.ResultsHbA1c levels significantly decreased from 8.5%±1.3% to 8.2%±1.2% during the follow-up (P<0.001 in all the study subjects (n=409. Among them, 35.5% (n=145 showed a significant improvement in HbA1c. Subjects covered under the Medical Aid system showed a higher prevalence of improvement in HbA1c than those with medical insurance (52.2% vs. 33.3%, respectively, P=0.012. In the improvement group, the baseline HbA1c (P<0.001, fasting C-peptide (P=0.016, and daily dose of insulin/body weight (P=0.024 showed significant negative correlations with the degree of HbA1c change. Multivariate analysis showed that subjects in the Medical Aid system were about 2.5-fold more likely to improve in HbA1c compared to those with medical insurance (odds ratio, 2.459; 95% confidence interval, 1.138 to 5.314; P=0.022.ConclusionThe reimbursement for SMBG resulted in a significant improvement in HbA1c in T2DM subjects using insulin, which was more prominent in subjects with poor glucose control at baseline or covered under the Medical Aid system.

  5. Effect of hemoglobin adjustment on the precision of mercury concentrations in maternal and cord blood

    DEFF Research Database (Denmark)

    Kim, Byung Mi; Choi, Anna L.; Ha, Eun Hee

    2014-01-01

    to be less precise than suggested by laboratory quality data, we studied the interrelationships of mercury concentrations with hemoglobin in paired maternal and cord blood samples from a Faroese birth cohort (N=514) and the Mothers and Children[U+05F3]s Environmental Health study in Korea (n=797). Linear...... and cord blood for hemoglobin improved their precision, while no significant effect of the selenium concentration in maternal blood was found. Adjustment of blood-mercury concentrations for hemoglobin is therefore recommended. © 2014 Elsevier Inc....

  6. Partial Least Square with Savitzky Golay Derivative in Predicting Blood Hemoglobin Using Near Infrared Spectrum

    Directory of Open Access Journals (Sweden)

    Mohd Idrus Mohd Nazrul Effendy

    2018-01-01

    Full Text Available Near infrared spectroscopy (NIRS is a reliable technique that widely used in medical fields. Partial least square was developed to predict blood hemoglobin concentration using NIRS. The aims of this paper are (i to develop predictive model for near infrared spectroscopic analysis in blood hemoglobin prediction, (ii to establish relationship between blood hemoglobin and near infrared spectrum using a predictive model, (iii to evaluate the predictive accuracy of a predictive model based on root mean squared error (RMSE and coefficient of determination rp2. Partial least square with first order Savitzky Golay (SG derivative preprocessing (PLS-SGd1 showed the higher performance of predictions with RMSE = 0.7965 and rp2= 0.9206 in K-fold cross validation. Optimum number of latent variable (LV and frame length (f were 32 and 27 nm, respectively. These findings suggest that the relationship between blood hemoglobin and near infrared spectrum is strong, and the partial least square with first order SG derivative is able to predict the blood hemoglobin using near infrared spectral data.

  7. 76 FR 51041 - Hemoglobin Standards and Maintaining Adequate Iron Stores in Blood Donors; Public Workshop

    Science.gov (United States)

    2011-08-17

    ...] Hemoglobin Standards and Maintaining Adequate Iron Stores in Blood Donors; Public Workshop AGENCY: Food and... Donors.'' The purpose of this public workshop is to discuss blood donor hemoglobin and hematocrit qualification standards in the United States, its impact on donor safety and blood availability, and potential...

  8. An innovative simple technique of blood conservation in adult patients with tetralogy of Fallot and severely raised hemoglobin.

    Science.gov (United States)

    Neema, Praveen Kumar; Manikandan, Sethuraman; Rathod, Ramesh Chandra

    2007-12-01

    The adult patients of tetralogy of Fallot often present with high hemoglobin levels. High hemoglobin and hematocrit on cardiopulmonary bypass (CPB) are associated with increased hemolysis, plasma free hemoglobin, renal dysfunction or failure, postoperative bleeding, exploration for bleeding, and increased requirement of allogeneic blood and blood products. Despite the presence of high hemoglobin and its association with adverse outcome, blood conservation is rarely practiced in these patients because of the fear of possible hemodynamic instability, and hypoxemic spell. We describe an innovative, simple technique of blood conservation for adult patients of tetralogy of Fallot with severely raised hemoglobin. With this technique, hemoglobin can be normalized on CPB; moreover, there is no fear of hypoxemic spell or hemodynamic instability. Furthermore, the blood conserved is readily available for transfusion in the perioperative period, if needed.

  9. A new method for detecting hemoglobin directly in whole blood using photon attenuation techniques

    International Nuclear Information System (INIS)

    Medhat, M.E.

    2014-01-01

    The objective of the proposed work is focused on measuring iron concentration directly in whole blood as tool for estimating hemoglobin and anemic conditions in patients across the world. The investigated method depends on theory of photon attenuation through transmission of low energy in whole blood sample. The mathematical expressions for calculating hemoglobin and iron deficit on blood using photon attenuation are derived. Calculations are carried out for estimating concentration of iron in blood samples taken from children, adults and old patients and therefore measuring their hemoglobin and iron deficit from normal values. Theoretical mass attenuation coefficient values were obtained using the XCOM program. A high-resolution gamma-ray spectrometry based on high purity germanium detector was employed to measure attenuation of strongly collimated monoenergetic gamma beam through blood samples. (author)

  10. An Innovative Simple Technique of Blood Conservation in Adult Patients with Tetralogy of Fallot and Severely Raised Hemoglobin

    OpenAIRE

    Neema, Praveen Kumar; Manikandan, Sethuraman; Rathod, Ramesh Chandra

    2007-01-01

    The adult patients of tetralogy of Fallot often present with high hemoglobin levels. High hemoglobin and hematocrit on cardiopulmonary bypass (CPB) are associated with increased hemolysis, plasma free hemoglobin, renal dysfunction or failure, postoperative bleeding, exploration for bleeding, and increased requirement of allogeneic blood and blood products. Despite the presence of high hemoglobin and its association with adverse outcome, blood conservation is rarely practiced in these patients...

  11. Removal of cellular-type hemoglobin-based oxygen carrier (hemoglobin-vesicles) from blood using centrifugation and ultrafiltration.

    Science.gov (United States)

    Sakai, Hiromi; Sou, Keitaro; Horinouchi, Hirohisa; Tsuchida, Eishun; Kobayashi, Koichi

    2012-02-01

    The hemoglobin-vesicle (HbV) is an artificial oxygen carrier encapsulating a concentrated hemoglobin solution in a phospholipid vesicle (liposome). During or after transporting oxygen, macrophages capture HbVs in the reticuloendothelial system (RES) with an approximate circulation half-life of 3 days. Animal studies show transient splenohepatomegaly after large doses, but HbVs were completely degraded, and the components were excreted in a few weeks. If a blood substitute is used for emergency use until red blood cell transfusion becomes available or for temporary use such as a priming fluid for an extracorporeal circuit, then one option would be to remove HbVs from the circulating blood without waiting a few weeks for removal by the RES. Using a mixture of beagle dog whole blood and HbV, we tested the separation of HbV using a centrifugal Fresenius cell separator and an ultrafiltration system. The cell separator system separated the layers of blood cell components from the HbV-containing plasma layer by centrifugal force, and then the HbV was removed from plasma phase by the ultrafiltration system. The HbVs (250-280 nm) are larger than plasma proteins (blood cell components (> 3 µm). The size of HbVs is advantageous to be separated from the original blood components, and the separated blood components can be returned to circulation. © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  12. 21 CFR 864.7500 - Whole blood hemoglobin assays.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Whole blood hemoglobin assays. 864.7500 Section 864.7500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Kits and Packages § 864.7500 Whole...

  13. Hemoglobin in samples with leukocytosis can be measured on ABL 700 series blood gas analyzers

    NARCIS (Netherlands)

    Scharnhorst, V.; Laar, van der P.D.; Vader, H.

    2003-01-01

    To compare lactate, bilirubin and Hemoglobin F concentrations obtained on ABL 700 series blood gas analyzers with those from laboratory methods. Pooled neonatal plasma, cord blood and adult plasma samples were used for comparison of bilirubin, hemoglobin F and lactate concentrations respectively.

  14. Thalassemia and Hemoglobin E in Southern Thai Blood Donors

    Directory of Open Access Journals (Sweden)

    Manit Nuinoon

    2014-01-01

    Full Text Available Thalassemia and hemoglobin E (Hb E are common in Thailand. Individuals with thalassemia trait usually have a normal hemoglobin concentration or mild anemia. Therefore, thalassemic individuals who have minimum acceptable Hb level may be accepted as blood donors. This study was aimed at determining the frequency of α-thalassemia 1 trait, β-thalassemia trait, and Hb E-related syndromes in Southern Thai blood donors. One hundred and sixteen voluntary blood donors, Southern Thailand origin, were recruited for thalassemia and Hb E screening by red blood cell indices/dichlorophenolindophenol precipitation test. β-Thalassemia and Hb E were then identified by high performance liquid chromatography and 4 common α-thalassemia deletions were characterized by a single tube-multiplex gap-polymerase chain reaction. Overall frequency of hemoglobinopathies was 12.9%, classified as follows: homozygous α-thalassemia 2 (1.7%, heterozygous α-thalassemia 1 (1.7%, heterozygous β-thalassemia without α-thalassemia (0.9%, heterozygous Hb E without α-thalassemia (5.2%, double heterozygotes for Hb E/α-thalassemia 1 (1.7%, homozygous Hb E without α-thalassemia (0.9%, and homozygous Hb E with heterozygous α-thalassemia 2 (0.9%. The usefulness of thalassemia screening is not only for receiving highly effective red blood cells in the recipients but also for encouraging the control and prevention program of thalassemia in blood donors.

  15. Thalassemia and Hemoglobin E in Southern Thai Blood Donors

    Science.gov (United States)

    Kruachan, Kwanta; Sengking, Warachaya; Horpet, Dararat; Sungyuan, Ubol

    2014-01-01

    Thalassemia and hemoglobin E (Hb E) are common in Thailand. Individuals with thalassemia trait usually have a normal hemoglobin concentration or mild anemia. Therefore, thalassemic individuals who have minimum acceptable Hb level may be accepted as blood donors. This study was aimed at determining the frequency of α-thalassemia 1 trait, β-thalassemia trait, and Hb E-related syndromes in Southern Thai blood donors. One hundred and sixteen voluntary blood donors, Southern Thailand origin, were recruited for thalassemia and Hb E screening by red blood cell indices/dichlorophenolindophenol precipitation test. β-Thalassemia and Hb E were then identified by high performance liquid chromatography and 4 common α-thalassemia deletions were characterized by a single tube-multiplex gap-polymerase chain reaction. Overall frequency of hemoglobinopathies was 12.9%, classified as follows: homozygous α-thalassemia 2 (1.7%), heterozygous α-thalassemia 1 (1.7%), heterozygous β-thalassemia without α-thalassemia (0.9%), heterozygous Hb E without α-thalassemia (5.2%), double heterozygotes for Hb E/α-thalassemia 1 (1.7%), homozygous Hb E without α-thalassemia (0.9%), and homozygous Hb E with heterozygous α-thalassemia 2 (0.9%). The usefulness of thalassemia screening is not only for receiving highly effective red blood cells in the recipients but also for encouraging the control and prevention program of thalassemia in blood donors. PMID:25050123

  16. Exploring the relationship of peripheral total bilirubin, red blood cell, and hemoglobin with blood pressure during childhood and adolescence.

    Science.gov (United States)

    Chen, Xiao-Tian; Yang, Song; Yang, Ya-Ming; Zhao, Hai-Long; Chen, Yan-Chun; Zhao, Xiang-Hai; Wen, Jin-Bo; Tian, Yuan-Rui; Yan, Wei-Li; Shen, Chong

    2017-11-04

    Total bilirubin is beneficial for protecting cardiovascular diseases in adults. The authors aimed to investigate the association of total bilirubin, red blood cell, and hemoglobin levels with the prevalence of high blood pressure in children and adolescents. A total of 3776 students (aged from 6 to 16 years old) were examined using cluster sampling. Pre-high blood pressure and high blood pressure were respectively defined as the point of 90th and 95th percentiles based on the Fourth Report on the Diagnosis, Evaluation, and Treatment of High Blood Pressure in Children and Adolescents. Both systolic and diastolic blood pressure were standardized into z-scores. Peripheral total bilirubin, red blood cell and hemoglobin levels were significantly correlated with age, and also varied with gender. Peripheral total bilirubin was negatively correlated with systolic blood pressure in 6- and 9-year-old boys, whilst positively correlated with diastolic blood pressure in the 12-year-old boys and 13- to 15-year-old girls (p0.05). Total bilirubin could be weakly correlated with both systolic and diastolic blood pressure, as correlations varied with age and gender in children and adolescents; in turn, the increased levels of red blood cell and hemoglobin are proposed to be positively associated with the prevalence of high blood pressure. Copyright © 2017 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  17. Blood lead: Its effect on trace element levels and iron structure in hemoglobin

    International Nuclear Information System (INIS)

    Jin, C.; Li, Y.; Li, Y.L.; Zou, Y.; Zhang, G.L.; Normura, M.; Zhu, G.Y.

    2008-01-01

    Lead is a ubiquitous environmental pollutant that induce a broad range of physiological and biochemical dysfunctions. The purpose of this study was to investigate its effects on trace elements and the iron structure in hemoglobin. Blood samples were collected from rats that had been exposed to lead. The concentration of trace elements in whole blood and blood plasma was determined by ICP-MS and the results indicate that lead exists mainly in the red blood cells and only about 1-3% in the blood plasma. Following lead exposure, the concentrations of zinc and iron in blood decrease, as does the hemoglobin level. This indicates that the heme biosynthetic pathway is inhibited by lead toxicity and that lead poisoning-associated anemia occurs. The selenium concentration also decreases after lead exposure, which may lead to an increased rate of free radical production. The effect of lead in the blood on iron structure in hemoglobin was determined by EXAFS. After lead exposure, the Fe-O bond length increases by about 0.07 A and the Fe-Np bond length slightly increases, but the Fe-N ε bond length remains unchanged. This indicates that the blood content of Hb increases, but that the content of HbO 2 decreases

  18. The Correlation of Hemoglobin A1c to Blood Glucose

    OpenAIRE

    Sikaris, Ken

    2009-01-01

    The understanding that hemoglobin A1c (HbA1c) represents the average blood glucose level of patients over the previous 120 days underlies the current management of diabetes. Even in making such a statement, we speak of “average blood glucose” as though “blood glucose” were itself a simple idea. When we consider all the blood glucose forms—arterial versus venous versus capillary, whole blood versus serum versus fluoride-preserved plasma, fasting versus nonfasting—we can start to see that this ...

  19. Age estimation of blood stains by hemoglobin derivative determination using reflectance spectroscopy

    NARCIS (Netherlands)

    Bremmer, Rolf H.; Nadort, Annemarie; van Leeuwen, Ton G.; van Gemert, Martin J. C.; Aalders, Maurice C. G.

    2011-01-01

    Blood stains can be crucial in reconstructing crime events. However, no reliable methods are currently available to establish the age of a blood stain on the crime scene. We show that determining the fractions of three hemoglobin derivatives in a blood stain at various ages enables relating these

  20. Whole Blood Donation Affects the Interpretation of Hemoglobin A1c

    NARCIS (Netherlands)

    Dijkstra, Angelique; Lenters-Westra, Erna; de Kort, Wim; Bokhorst, Arlinke G.; Bilo, Henk J. G.; Slingerland, Robbert J.; Vos, Michel J.

    2017-01-01

    Several factors, including changed dynamics of erythrocyte formation and degradation, can influence the degree of hemoglobin A1c (HbA1c) formation thereby affecting its use in monitoring diabetes. This study determines the influence of whole blood donation on HbA1c in both non-diabetic blood donors

  1. Capillary versus Venous Hemoglobin Determination in the Assessment of Healthy Blood Donors

    Science.gov (United States)

    Patel, Abhilasha J.; Wesley, Robert; Leitman, Susan F.; Bryant, Barbara J.

    2013-01-01

    Background and Objectives To determine the accuracy of fingerstick hemoglobin assessment in blood donors, the performance of a portable hemoglobinometer (HemoCue Hb 201+) was prospectively compared with that of an automated hematology analyzer (Cell-Dyn 4000). Hemoglobin values obtained by the latter were used as the “true” result. Material and Methods Capillary fingerstick samples were assayed by HemoCue in 150 donors. Fingerstick samples from two sites, one on each hand, were obtained from a subset of 50 subjects. Concurrent venous samples were tested using both HemoCue and Cell-Dyn devices. Results Capillary hemoglobin values (HemoCue) were significantly greater than venous hemoglobin values (HemoCue), which in turn were significantly greater than venous hemoglobin values by Cell-Dyn (mean ± SD: 14.05 ± 1.51, 13.89 ± 1.31, 13.62 ± 1.23, respectively; phemoglobin screening criteria (≥12.5 g/dL) by capillary HemoCue, but were deferred by Cell-Dyn values (false-pass). Five donors (3%) were deferred by capillary sampling, but passed by Cell-Dyn (false-fail). Substantial variability in repeated fingerstick HemoCue results was seen (mean hemoglobin 13.72 vs. 13.70 g/dL, absolute mean difference between paired samples 0.76 g/dL). Hand dominance was not a factor. Conclusions Capillary samples assessed via a portable device yielded higher hemoglobin values than venous samples assessed on an automated analyzer. False-pass and false-fail rates were low and acceptable in the donor screening setting, with “true” values not differing by a clinically significant degree from threshold values used to assess acceptability for blood donation. PMID:23294266

  2. Hemoglobin, hematocrit, and changes in cerebral blood flow : The Second Manifestations of ARTerial disease-Magnetic Resonance study

    NARCIS (Netherlands)

    van der Veen, Pieternella H.; Muller, Majon; Vincken, Koen L.; Westerink, Jan; Mali, Willem P. T. M.; van der Graaf, Yolanda; Geerlings, Mirjam I.; Doevendans, PAFM

    Hemoglobin and hematocrit are important determinants of blood viscosity and arterial oxygen content and may therefore influence cerebral blood flow (CBF). We examined cross-sectional and prospective associations of hemoglobin and hematocrit with CBF in 569 patients with manifest arterial disease

  3. Oral health and glycosylated hemoglobin among type 1 diabetes children in South India

    Directory of Open Access Journals (Sweden)

    K Vidya

    2018-01-01

    Full Text Available Background: The study was an attempt to evaluate the relationship between oral health status and the level of glycemic control in type 1 diabetes patients. Methods: The study was carried out in 87 children with type 1 diabetes, aged 8–16 years, attending a diabetes specialty hospital. The oral health of these patients was measured using the WHO 1997 Oral Health Survey criteria for diagnosis of dental caries, gingival index, and plaque index. Samples were then divided into two groups as controlled (≤6.99% glycosylated hemoglobin [HbA1c] and uncontrolled (≥7% HbA1c diabetes as per the guidelines for glycemic control in diabetics given by the American Diabetes Association. The oral health between the groups was compared. Results: Data were statistically analyzed using student t-test. Results showed a significant difference in decayed, missing, and filled surface component (P = 0.043 and gingival index scores (P< 0.001 in the permanent dentition between controlled and uncontrolled groups but not in case of the primary dentition. Conclusions: The data findings suggest that metabolic control had an impact on caries prevalence and gingival health of these patients, in case of permanent dentition. As the glycemic control became poorer, the caries prevalence and gingival inflammation increased. When primary dentition was taken into consideration, the correlation was not significant.

  4. (Pyridoxylated hemoglobin)-(polyoxyethylene) conjugate solution as blood substitute for normothermic whole body rinse-out.

    Science.gov (United States)

    Agishi, T; Funakoshi, Y; Honda, H; Yamagata, K; Kobayashi, M; Takahashi, M

    1988-01-01

    In order to investigate a new possibility for artificial blood with oxygen-carrying capability to be applied to other than mere supplementation, normothermic whole body rinse-out in which artificial blood deriving from perfluorochemical emulsion, Fluosol-DA 20% (Green Cross Co., Ltd., Osaka, Japan) or stabilized hemoglobin solution, (pyridoxylated hemoglobin)-(polyoxyethylene) conjugate solution (Ajinomoto Co., Ltd., Tokyo, Japan) were used as rinsing fluid for a blood purification experiment. Replacement either with approximately 150 ml/kg of Fluosol-DA or stabilized hemoglobin solution showed effective removal of digoxin at a reduction rate of 96.3% or 92.2%, respectively. However, when Fluosol-DA was used, a certain amount of perfluorochemical should be retrieved by centrifugation to avoid a possible toxic effect on the reticulo-endothelial system. Even though 3 out of 6, and 3 out of 8 dogs, respectively, survived for a long period after the procedure, the experimental dogs were very susceptible to infection.

  5. Hemoglobin C disease

    Science.gov (United States)

    Clinical hemoglobin C ... Hemoglobin C is an abnormal type of hemoglobin, the protein in red blood cells that carries oxygen. It is ... Americans. You are more likely to have hemoglobin C disease if someone in your family has had ...

  6. Inhibition mechanisms of hemoglobin, immunoglobulin G, and whole blood in digital and real-time PCR.

    Science.gov (United States)

    Sidstedt, Maja; Hedman, Johannes; Romsos, Erica L; Waitara, Leticia; Wadsö, Lars; Steffen, Carolyn R; Vallone, Peter M; Rådström, Peter

    2018-04-01

    Blood samples are widely used for PCR-based DNA analysis in fields such as diagnosis of infectious diseases, cancer diagnostics, and forensic genetics. In this study, the mechanisms behind blood-induced PCR inhibition were evaluated by use of whole blood as well as known PCR-inhibitory molecules in both digital PCR and real-time PCR. Also, electrophoretic mobility shift assay was applied to investigate interactions between inhibitory proteins and DNA, and isothermal titration calorimetry was used to directly measure effects on DNA polymerase activity. Whole blood caused a decrease in the number of positive digital PCR reactions, lowered amplification efficiency, and caused severe quenching of the fluorescence of the passive reference dye 6-carboxy-X-rhodamine as well as the double-stranded DNA binding dye EvaGreen. Immunoglobulin G was found to bind to single-stranded genomic DNA, leading to increased quantification cycle values. Hemoglobin affected the DNA polymerase activity and thus lowered the amplification efficiency. Hemoglobin and hematin were shown to be the molecules in blood responsible for the fluorescence quenching. In conclusion, hemoglobin and immunoglobulin G are the two major PCR inhibitors in blood, where the first affects amplification through a direct effect on the DNA polymerase activity and quenches the fluorescence of free dye molecules, and the latter binds to single-stranded genomic DNA, hindering DNA polymerization in the first few PCR cycles. Graphical abstract PCR inhibition mechanisms of hemoglobin and immunoglobulin G (IgG). Cq quantification cycle, dsDNA double-stranded DNA, ssDNA single-stranded DNA.

  7. Blood Test: Hemoglobin A1C

    Science.gov (United States)

    ... Why Are Hemoglobin A1c Tests Done? When a child has diabetes, hemoglobin A1c levels are followed to see how well medicines are working. If a child with diabetes has a high hemoglobin A1c level, it may ...

  8. Reference ranges for hematocrit and blood hemoglobin concentration during the neonatal period: data from a multihospital health care system.

    Science.gov (United States)

    Jopling, Jeffery; Henry, Erick; Wiedmeier, Susan E; Christensen, Robert D

    2009-02-01

    "Reference ranges" are developed when it is impossible or inappropriate to establish "normal ranges" by drawing blood on healthy normal volunteers. Reference ranges for the hematocrit and the blood hemoglobin concentration of newborn infants have previously been reported from relatively small sample sizes by using measurement methods that now are considered outmoded. We sought to develop reference ranges for hematocrit and hemoglobin during the neonatal period (28 days) by using very large sample sizes and modern hematology analyzers, accounting for gestational and postnatal age and gender. Data were assembled from a multihospital health care system after exclusion of patients with a high likelihood of an abnormal value and those who were receiving blood transfusions. During the interval from 22 to 40 weeks' gestation, the hematocrit and blood hemoglobin concentration increased approximately linearly. For every week advance in gestational age, the hematocrit increased by 0.64% and the hemoglobin concentration increased by 0.21 g/dL. No difference was seen on the basis of gender. During the 4-hour interval after birth, hematocrit/hemoglobin values of late preterm and term neonates (35-42 weeks' gestation) increased by 3.6% +/- 0.5% (mean +/- SD), those of neonates of 29 to 34 weeks' gestation remained unchanged, and those of hematocrit/hemoglobin occurred. The figures presented herein describe reference ranges for hematocrit and blood hemoglobin concentration during the neonatal period, accounting for gestational and postnatal age.

  9. Substitution of Fingertip Blood for Venous Blood in the Measurement of Hematocrit and Hemoglobin Following Exercise

    Science.gov (United States)

    Fahey, Thomas D.; And Others

    1977-01-01

    Results from comparative testing indicate that fingertip blood is a valid indicator of antecubital venous hematocrit (hct) and hemoglobin (hgb), and that hct ratios determined on the Coulter counter are comparable to those found by the microhematocrit method. (MB)

  10. Hemopressins and other hemoglobin-derived peptides in mouse brain: Comparison between brain, blood, and heart peptidome and regulation in Cpefat/fat mice

    Science.gov (United States)

    Gelman, Julia S.; Sironi, Juan; Castro, Leandro M.; Ferro, Emer S.; Fricker, Lloyd D.

    2010-01-01

    Many hemoglobin-derived peptides are present in mouse brain, and several of these have bioactive properties including the hemopressins, a related series of peptides that bind to cannabinoid CB1 receptors. Although hemoglobin is a major component of red blood cells, it is also present in neurons and glia. To examine whether the hemoglobin-derived peptides in brain are similar to those present in blood and heart, we used a peptidomics approach involving mass spectrometry. Many hemoglobin-derived peptides are found only in brain and not in blood, whereas all hemoglobin-derived peptides found in heart were also seen in blood. Thus, it is likely that the majority of the hemoglobin-derived peptides detected in brain are produced from brain hemoglobin and not erythrocytes. We also examined if the hemopressins and other major hemoglobin-derived peptides were regulated in the Cpefat/fat mouse; previously these mice were reported to have elevated levels of several hemoglobin-derived peptides. Many, but not all of the hemoglobin-derived peptides were elevated in several brain regions of the Cpefat/fat mouse. Taken together, these findings suggest that the post-translational processing of alpha and beta hemoglobin into the hemopressins, as well as other peptides, is upregulated in some but not all Cpefat/fat mouse brain regions. PMID:20202081

  11. Does Physical Activity Mediate the Associations Between Local-Area Descriptive Norms, Built Environment Walkability, and Glycosylated Hemoglobin?

    Science.gov (United States)

    Carroll, Suzanne J; Niyonsenga, Theo; Coffee, Neil T; Taylor, Anne W; Daniel, Mark

    2017-08-23

    Associations between local-area residential features and glycosylated hemoglobin (HbA 1c ) may be mediated by individual-level health behaviors. Such indirect effects have rarely been tested. This study assessed whether individual-level self-reported physical activity mediated the influence of local-area descriptive norms and objectively expressed walkability on 10-year change in HbA 1c . HbA 1c was assessed three times for adults in a 10-year population-based biomedical cohort ( n = 4056). Local-area norms specific to each participant were calculated, aggregating responses from a separate statewide surveillance survey for 1600 m road-network buffers centered on participant addresses (local prevalence of overweight/obesity (body mass index ≥25 kg/m²) and physical inactivity (Walkability was directly and indirectly protective of worsening HbA 1c . Local-area descriptive norms and walkability influence cardiometabolic risk trajectory through individual-level physical activity. Efforts to reduce population cardiometabolic risk should consider the extent of local-area unhealthful behavioral norms and walkability in tailoring strategies to improve physical activity.

  12. Evaluation of three methods for hemoglobin measurement in a blood donor setting

    Directory of Open Access Journals (Sweden)

    Jacob Rosenblit

    1999-05-01

    Full Text Available CONTEXT: The hemoglobin (Hb level is the most-used parameter for screening blood donors for the presence of anemia, one of the most-used methods for measuring Hb levels is based on photometric detection of cyanmetahemoglobin, as an alternative to this technology, HemoCue has developed a photometric method based on the determination of azide metahemoglobin. OBJECTIVE: To evaluate the performance of three methods for hemoglobin (Hb determination in a blood bank setting. DESIGN: Prospective study utilizing blood samples to compare methods for Hb determination. SETTING: Hemotherapy Service of the Hospital Israelita Albert Einstein, a private institution in the tertiary health care system. SAMPLE: Serial blood samples were collected from 259 individuals during the period from March to June 1996. MAIN MEASUREMENTS: Test performances and their comparisons were assessed by the analysis of coefficients of variation (CV, linear regression and mean differences. RESULTS: The CV for the three methods were: Coulter 0.68%, Cobas 0.82% and HemoCue 0.69%. There was no difference between the mean Hb determination for the three methods (p>0.05. The Coulter and Cobas methods showed the best agreement and the HemoCue method gave a lower Hb determination when compared to both the Coulter and Cobas methods. However, pairs of methods involving the HemoCue seem to have narrower limits of agreement (± 0.78 and ± 1.02 than the Coulter and Cobas combination (± 1.13. CONCLUSION: The three methods provide good agreement for hemoglobin determination.

  13. Diode laser irradiation of rat blood and its effect on hemoglobin and plasma

    International Nuclear Information System (INIS)

    Saad-El-Din, A.A.; El-Ahdaal, M.A.; Omran, M.F.

    2002-01-01

    Blood was exposed to diode laser irradiation of wavelength 830 nm and maximum powe of 31.4 MW, with exposure times 15, 30, 45 and 60 minutes. Hemoglobin IR spectra and X-ray crystallography, plasma Na + , K + , Ca + +. cholesterol concentrations and viscosity were measured. There were changes in hemoglobin amide groups as well as changes in the X-ray in hemoglobin structure. Decreases in both Na concentration and plasma viscosity occurred at 15 and 30 minutes of laser exposure. On increasing time to 45 and 60 minutes, the Na concentration and viscosity were increased. K, Ca and cholesterol concentration were decreased linearly with time. Na / K ratio was increased also with time of exposure. The results have been indicated that the diode laser affect the secondary structure of hemoglobin, membranes structures and plasma

  14. Hemoglobin (image)

    Science.gov (United States)

    Hemoglobin is the most important component of red blood cells. It is composed of a protein called ... exchanged for carbon dioxide. Abnormalities of an individual's hemoglobin value can indicate defects in the normal balance ...

  15. Prevalence and determinants of declining versus stable hemoglobin levels in whole blood donors

    NARCIS (Netherlands)

    Nasserinejad, Kazem; van Rosmalen, Joost; van den Hurk, Katja; Baart, Mireille; Hoekstra, Trynke; Rizopoulos, Dimitris; Lesaffre, Emmanuel; de Kort, Wim

    2015-01-01

    A too short recovery time after blood donation results in a gradual depletion of iron stores and a subsequent decline in hemoglobin (Hb) levels over time. This decline in Hb levels may depend on individual, unobserved characteristics of the donor. We used a data set of 5388 Dutch blood donors from

  16. The Association of Increased Total Glycosylated Hemoglobin Levels with Delayed Age at Menarche in Young Women with Type 1 Diabetes

    Science.gov (United States)

    Danielson, Kirstie K.; Palta, Mari; Allen, Catherine; D’Alessio, Donn J.

    2005-01-01

    Context: Delayed menarche is associated with subsequent reproductive and skeletal complications. Previous research has found delayed growth and pubertal maturation with type 1 diabetes and with poor glycemic control. The effect of diabetes management on menarche is important to clarify because tighter control might prevent these complications. Objective: To investigate age at menarche in young women with type 1 diabetes, and examine the effect of diabetes management (e.g. total glycosylated hemoglobin (GHb) level, number of blood glucose checks, insulin therapy intensity, insulin dose) on age at menarche in those diagnosed before menarche. Design: The Wisconsin Diabetes Registry Project is a follow-up study of a type 1 diabetes population-based incident cohort initially enrolled 1987 – 1992. Setting: Twenty-eight counties in south-central Wisconsin. Patients or Other Participants: Recruited through referrals, self-report, and hospital/clinic ascertainment. Individuals with newly diagnosed type 1 diabetes, <30 years old, were invited to participate. Of 288 young women enrolled, 188 reported menarche by 2002; 105 were diagnosed before menarche. Interventions: Not applicable. Main Outcome Measure: Age at menarche. Results: Mean age at menarche was 12.78 years, compared to 12.54 years in the United States (p = 0.01). Ages at menarche and diagnosis were not associated. For those diagnosed before menarche, age at menarche was delayed 1.3 months with each one percent increase in mean total GHb level in the three years prior to menarche. Conclusions: Age at menarche was moderately delayed in young women with type 1 diabetes. Delayed menarche could potentially be minimized with improved GHb levels. PMID:16204372

  17. Elevated Hemoglobin A1C Levels Correlate with Blood Glucose Elevation in Diabetic Patients following Local Corticosteroid Injection in the Hand: A Prospective Study.

    Science.gov (United States)

    Kim, Nayoung; Schroeder, Jake; Hoffler, C Edward; Matzon, Jonas L; Lutsky, Kevin F; Beredjiklian, Pedro K

    2015-10-01

    Diabetic patients develop hand conditions that are managed with local corticosteroid injections. Injections can result in a transient elevation in serum glucose in diabetic patients. Hemoglobin A1c is the accepted measure of long-term plasma glucose control in diabetics (levels ≥7 percent reflect poor blood glucose control). The purpose of this study was to assess the relationship between hemoglobin A1c levels and increased blood glucose levels after corticosteroid injections. Twenty-five diabetic patients were evaluated prospectively. One milliliter containing 10 mg of triamcinolone acetonide was used. The most recent hemoglobin A1c level and normal average blood glucose levels were obtained. Glucose levels were obtained from patient recall of their daily blood glucose self- monitoring on the day of the injection. Postinjection blood glucose levels were recorded until levels returned to preinjection baseline. Twenty patients (80 percent) had elevation of their blood glucose level from baseline. No patient had elevated blood glucose levels after 5 days. Patients with hemoglobin A1c levels greater than or equal to 7 percent had a higher blood glucose elevation and maintained this for longer than those who had a lower hemoglobin A1c level. Patients in the higher hemoglobin A1c group also had a higher number of hyperglycemic events. There was a strong or moderate correlation between hemoglobin A1c and elevated blood glucose levels during days 1 to 4. Patients with hemoglobin A1c levels greater than or equal to 7 percent have elevations in blood glucose that are higher and last longer than patients with lower levels. Hemoglobin A1c levels can be used to roughly predict the degree of blood glucose elevation after corticosteroid injections into the hands of diabetic patients.

  18. Whole Blood Donation Affects the Interpretation of Hemoglobin A(1c)

    NARCIS (Netherlands)

    Dijkstra, Angelique; Lenters-Westra, Erna; de Kort, Wim; Bokhorst, Arlinke G.; Bilo, Henk J. G.; Slingerland, Robbert J.; Vos, Michel J.

    2017-01-01

    Introduction Several factors, including changed dynamics of erythrocyte formation and degradation, can influence the degree of hemoglobin A(1c) (HbA(1c)) formation thereby affecting its use in monitoring diabetes. This study determines the influence of whole blood donation on HbA(1c) in both

  19. Graphene based chalcogenide fiber-optic evanescent wave sensor for detection of hemoglobin in human blood

    Science.gov (United States)

    Sharma, Anuj K.; Gupta, Jyoti

    2018-03-01

    Fiber optic evanescent wave sensor with graphene as an absorption-enhancing layer to measure hemoglobin concentration in human blood is proposed. Previous modal functions and experimental results describing the variation of optical constants of human blood with different hemoglobin concentrations in the near-infrared spectral region are considered for sensor design simulation. The sensor's performance is closely analyzed in terms of its absorption coefficient, sensitivity, and detection limit. It is found that the proposed sensor should be operated at longer light wavelength to get more enhanced sensitivity and smaller detection limit. At 1000 nm wavelength, a detection limit of 18 μg/dL and sensitivity of 6.71 × 10-4 per g/dL is achievable with the proposed sensor. The sensitivity is found to be better for larger hemoglobin concentrations. The results are correlated with the evanescent wave penetration depth.

  20. The relationship between extent of hemoglobin purification and the performance characteristics of a blood-based flocculant

    Science.gov (United States)

    Whole blood is a highly complex substance. Hemoglobin, the most abundant blood protein, can function as a flocculant of colloidal clay; most of the other blood components exhibit poor flocculant activity. For the purpose of processing raw whole blood into a flocculant product, the practical value of...

  1. The Association of Serum Cystatin C with Glycosylated Hemoglobin in Korean Adults

    Directory of Open Access Journals (Sweden)

    Eun Hee Sim

    2016-01-01

    Full Text Available BackgroundCystatin C has been known to be associated not only with early renal impairment but also with the incidence of diabetic conditions (prediabetes plus diabetes. However, it is not clear whether cystatin C levels are associated with the prevalence of diabetic conditions in Asian populations. We evaluated this association using glycosylated hemoglobin (HbA1c levels as the definition of diabetes in Korean adults.MethodsWe analyzed data from 1,559 Korean adults (937 men and 622 women with available serum cystatin C and HbA1c values.ResultsThe serum cystatin C levels in subjects with prediabetes and diabetes were significantly increased (0.91±0.14 mg/L in prediabetes and 0.91±0.17 mg/L in diabetes vs. 0.88±0.13 mg/L in patients with normal glucose levels, P=0.001. At increasing cystatin C levels, the prevalence of subjects with prediabetes (30.2% vs. 14.6%, P<0.001 and those with diabetes (10.6% vs. 8.0%, P<0.001 significantly increased in the group with the highest cystatin C levels. The group with the highest cystatin C levels had a significantly increased odds ratio (OR for the presence of diabetic conditions compared to the group with the lowest values in total subjects (OR, 2.35; 95% confidence interval [CI], 1.54 to 3.58; P<0.001 and in women (OR, 4.13; 95% CI, 1.97 to 8.65; P<0.001, though there was no significant increase after adjusting for multiple variables.ConclusionsHigher levels of serum cystatin C are associated with an increased prevalence of diabetic conditions in Korean adults. Our findings may extend the positive association of cystatin C with diabetes incidence to an Asian population.

  2. Optoacoustic monitoring of blood hemoglobin concentration: a pilot clinical study

    Science.gov (United States)

    Petrova, Irina Y.; Esenaliev, Rinat O.; Petrov, Yuriy Y.; Brecht, Hans-Peter F.; Svensen, Christer H.; Olsson, Joel; Deyo, Donald J.; Prough, Donald S.

    2005-07-01

    The optoacoustic technique is noninvasive, has high spatial resolution, and potentially can be used to measure the total hemoglobin concentration ([THb]) continuously and accurately. We performed in vitro measurements in blood and in vivo tests in healthy volunteers. Our clinical protocol included rapid infusion of intravenous saline to simulate rapid change in the [THb] during fluid therapy or surgery. Optoacoustic measurements were made from the wrist area overlying the radial artery for more than 1 h. The amplitude of the optoacoustic signal generated in the radial artery closely followed the [THb] measured directly in concurrently collected blood samples.

  3. Association between elevated pre-operative glycosylated hemoglobin and post-operative infections after non-emergent surgery.

    Science.gov (United States)

    Blankush, Joseph M; Leitman, I Michael; Soleiman, Aron; Tran, Trung

    2016-09-01

    A chronic state of impaired glucose metabolism affects multiple components of the immune system, possibly leading to an increased incidence of post-operative infections. Such infections increase morbidity, length of stay, and overall cost. This study evaluates the correlation between elevated pre-operative glycosylated hemoglobin (HbA1c) and post-operative infections. Adult patients undergoing non-emergent procedures across all surgical subspecialties from January 2010 to July 2014 had a preoperative HbA1c measured as part of their routine pre-surgical assessment. 2200 patient charts (1100 operative infection (superficial surgical site infection, deep wound/surgical space abscess, pneumonia, and/or urinary tract infection as defined by Centers for Disease Control criteria) within 30 days of surgery. Patients with HbA1c infection rate (3.8% in the HbA1c infection. Elevated HbA1c was, however, predictive of significantly increased risk of post-operative infection when associated with increased age (≥81 years of age) or dirty wounds. The risk factors of post-operative infection are multiple and likely synergistic. While pre-operative HbA1c level is not independently associated with risk of post-operative infection, there are scenarios and patient subgroups where pre-operative HbA1c is useful in predicting an increased risk of infectious complications in the post-operative period.

  4. The relationship between periapical lesions and the serum levels of glycosylated hemoglobin and C-reactive protein in type 2 diabetic patients

    Directory of Open Access Journals (Sweden)

    Mohammad S. Al-Zahrani

    2017-01-01

    Full Text Available Objectives: To investigate the relationship between the presence of periapical lesions (PL and levels of glycosylated hemoglobin (HbA1c, and C-reactive protein (CRP in patients with type 2 diabetes. Methods: This cross-sectional study was conducted at Ibn Sina National College for Medical Studies, Jeddah, Kingdom of Saudi Arabia, between September 2013 and February 2015. Medical and dental history and Sociodemographic data were obtained from participants. Dental and periodontal examinations were conducted and blood samples were obtained to determine levels of HbA1c and CRP. The presence of PL was recorded from panoramic and periapical radiographs. Descriptive statistics and multivariable linear and logistic regression models were used for data analyses. Results: One hundred patients were included; mean age was 48.9 ± 8.5 years. Of these patients, 14% had no PL, whereas 25% had one or 2 lesions, 32% had 3 or 4 lesions, and 29% had ≥5 PL. The mean HbA1c was 9.8% (± 2.5 mg/L and CRP was 6.9 mg/L (± 6.3. The presence of PL was significantly associated with a higher level of HbA1c independent of age, gender, probing depth, and plaque index (p=0.023. Individuals with PL were also more likely to have a high CRP level (>3 mg/L independent of the previous covariates (odds ratio: 1.19; 95% confidence interval: 1.01-1.41. Conclusion: Periapical lesions are associated with a poorer glycemic control and a higher CRP level in type 2 diabetic patients.

  5. Outcome analysis of hemoglobin A1c, weight, and blood pressure in a VA diabetes education program.

    Science.gov (United States)

    North, Susan L; Palmer, Glen A

    2015-01-01

    To determine the effect of a specific diabetes education class (Basics) on hemoglobin A1c values, weight, and systolic blood pressure. In this retrospective study, the researchers compared 2 groups of male veterans with a recent diagnosis of type 2 diabetes. One group received diabetes group education (n = 175) over a 4-month period, and the other received standard diabetes management follow-up (n = 184). Outpatient clinic setting in the Midwest. Basics class compared with standard level of care. Pre- and post-laboratory values for hemoglobin A1c, weight, and systolic blood pressure. Multivariate analysis of covariance and follow-up univariate statistics for significant differences. Findings revealed significant differences in hemoglobin A1c (P education curriculum and reduction of hemoglobin A1c values. Some participants also had added benefit of significant weight loss. Published by Elsevier Inc.

  6. Time course for the recovery of physical performance, blood hemoglobin, and ferritin content after blood donation

    DEFF Research Database (Denmark)

    Ziegler, Andreas K; Grand, Johannes; Stangerup, Ida

    2015-01-01

    BACKGROUND: It is widely accepted that blood donation negatively affects endurance performance, but data on physical recovery after a standard blood donation are scarce. This study aimed to elucidate the temporary impact of blood donation on endurance performance, measured as peak oxygen uptake (VO......2peak ) and time trial (TT) performance. STUDY DESIGN AND METHODS: VO2peak , TT performance, blood, iron, and anthropometric variables were determined before (baseline) and 3, 7, 14, and 28 days after blood donation in 19 healthy men. RESULTS: VO2peak was reduced by 6.5% from 49.7 ± 2 m......L/kg/min at baseline to 46.3 ± 2 mL/kg/min on Day 3 (p donation. Blood hemoglobin (Hb) concentration declined 7.9% from 9.3 ± 0.11 mmol...

  7. Associations between long-term exposure to ambient particulate air pollution and type 2 diabetes prevalence, blood glucose and glycosylated hemoglobin levels in China

    Science.gov (United States)

    Zhao, Yaohui; Ma, Zongwei; Bi, Jun; Liu, Yang; Meng, Xia; Wang, Yafeng; Cai, Jing; Chen, Renjie; Kan, Haidong

    2016-01-01

    Background The evidence for an association between particulate air pollution and type 2 diabetes mellitus (T2DM) in developing countries was very scarce. Objective To investigate the associations of long-term exposure to fine particulate matter (PM2.5) with T2DM prevalence and with fasting glucose and glycosylated hemoglobin (HbA1c) levels in China. Methods This is a cross-sectional study based on a nation-wide baseline survey of 11,847 adults who participated in the China Health and Retirement Longitudinal Study from June 2011 to March 2012. The average residential exposure to PM2.5 for each participant in the same period was estimated using a satellite-based spatial statistical model. We determined the association between PM2.5 and T2DM prevalence by multivariable logistic regression models. We also evaluated the association between PM2.5 and fasting glucose and HbA1c levels using multivariable linear regression models. Stratification analyses were conducted to explore potential effect modification. Results We identified 1,760 cases of T2DM, corresponding to 14.9% of the study population. The average PM2.5 exposure for all participants was 72.6 μg/m3 during the study period. An interquartile range increase in PM2.5 (41.1μg/m3) was significantly associated with increased T2DM prevalence (prevalence ratio, PR=1.14), and elevated levels of fasting glucose (0.26 mmol/L) and HbA1c (0.08%). The associations of PM2.5 with T2DM prevalence and with fasting glucose and HbA1c were stronger in several subgroups. Conclusions This nationwide cross-sectional study suggested that long-term exposure to PM2.5 might increase the risk of T2DM in China. PMID:27148900

  8. Relationships between hemoglobin A1c and spot glucose ...

    African Journals Online (AJOL)

    Background: Glycosylated hemoglobin, HbA1c is the most acceptable measure of chronic glycemia. It is not widely available and/or affordable in Nigeria. The mean of the monthly fasting plasma glucose (MFPG) of the preceding 3 months is often used as surrogate for assessing chronic glycemia. Objective: To determine the ...

  9. Handling low hemoglobin and iron deficiency in a blood donor population

    DEFF Research Database (Denmark)

    Magnussen, Karin; Ladelund, Steen

    2016-01-01

    BACKGROUND: Iron deficiency and blood donors with low hemoglobin (Hb) concentration are well-known challenges in any blood bank setting. In the Capital Region of Denmark, a new approach was adopted that centralized measurement of Hb, initiated ferritin (F) measurement, and established a center......: The change in Hb for repeat donors was followed during the first 2 years of the intervention strategy, which included measurements of F and offering intermittent iron supplementation to some of the donors. RESULTS: In 2 years, 62,663 blood donors donated 193,288 units of blood and 318 donors gave 754...... complete blood count blood samples. Over time in the repeat donors, the Hb increased from 15.39 to 15.60 g/dL and 13.85 to 14.06 g/dL in male and female donors, respectively, and the proportion of donors with low Hb decreased from 0.9% to 0.3% and 3.9% to 2.7% for the male and female donors, respectively...

  10. The relationship between periapical lesions and the serum levels of glycosylated hemoglobin and C-reactive protein in type 2 diabetic patients.

    Science.gov (United States)

    Al-Zahrani, Mohammad S; Abozor, Basel M; Zawawi, Khalid H

    2017-01-01

    To investigate the relationship between the presence of periapical lesions (PL) and levels of glycosylated hemoglobin (HbA1c), and C-reactive protein (CRP) in patients with type 2 diabetes.  Methods: This cross-sectional study was conducted at Ibn Sina National College for Medical Studies, Jeddah, Kingdom of Saudi Arabia, between September 2013 and February 2015. Medical and dental history and Sociodemographic data were obtained from participants. Dental and periodontal examinations were conducted and blood samples were obtained to determine levels of HbA1c and CRP. The presence of PL was recorded from panoramic and periapical radiographs. Descriptive statistics and multivariable linear and logistic regression models were used for data analyses.  Results: One hundred patients were included; mean age was 48.9 ± 8.5 years. Of these patients, 14% had no PL, whereas 25% had one or 2 lesions, 32% had 3 or 4 lesions, and 29% had ≥5 PL. The mean HbA1c was 9.8% (± 2.5) mg/L and CRP was 6.9 mg/L (± 6.3). The presence of PL was significantly associated with a higher level of HbA1c independent of age, gender, probing depth, and plaque index (p=0.023). Individuals with PL were also more likely to have a high CRP level (greater than 3 mg/L) independent of the previous covariates (odds ratio: 1.19; 95% confidence interval: 1.01-1.41).  Conclusion: Periapical lesions are associated with a poorer glycemic control and a higher CRP level in type 2 diabetic patients.

  11. Autologous blood sequestration using a double venous reservoir bypass circuit and polymerized hemoglobin prime.

    Science.gov (United States)

    Neragi-Miandoab, Siyamek; Guerrero, J Luis; Vlahakes, Gus J

    2002-01-01

    Cardiac surgery often necessitates transfusion of homologous blood. Hemoglobin based oxygen carrying solutions (HBOCs) transport oxygen, suggesting use in cardiopulmonary bypass. HBOC was used in a novel oxygenator double-reservoir circuit that permits acute sequestration of a portion of the autologous blood volume during bypass. Two groups of seven mongrel dogs each were studied in an experimental bypass model using global myocardial ischemia and cardioplegia protection: HBOC group, initial venous return drained to a separate reservoir and hypothermic bypass was conducted with HBOC containing perfusate in a second bypass reservoir; Control group, crystalloid prime in a conventional circuit. Hemodynamics and metabolic and hematologic parameters were measured before and 60 min after aortic clamp removal and reinfusion of sequestered autologous blood. Blood gases, base excess, hematocrit, total hemoglobin, and platelet counts were measured. In the HBOC group, metabolic acidosis did not occur, and ventricular function was preserved. Net conservation of platelets was noted at study conclusion: control 33+/-13 x 10(3) per mm3 versus HBOC 48+/-13 x 10(3), p conservation of the platelet mass occurs, a portion of which is not exposed to the deleterious effects of hypothermia and cardiopulmonary bypass.

  12. In vitro adduct formation of phosgene with albumin and hemoglobin in human blood

    NARCIS (Netherlands)

    Noort, D.; Hulst, A.G.; Fidder, A.; Gurp, R.A. van; Jong, L.P.A. de; Benschop, H.P.

    2000-01-01

    The development of procedures for retrospective detection and quantitation of exposure to phosgene, based on adducts to hemoglobin and albumin, is described. Upon incubation of human blood with [14C]phosgene (0-750 μM), a significant part of radioactivity (0-13%) became associated with globin and

  13. Prevalence and determinants of declining versus stable hemoglobin levels in whole blood donors

    NARCIS (Netherlands)

    Nasserinejad, K.; van Rosmalen, J.; van den Hurk, K.; Baart, M.; Hoekstra, T.; Rizopoulos, D.; Lesaffre, E.; Kort, W.

    2015-01-01

    Background A too short recovery time after blood donation Results in a gradual depletion of iron stores and a subsequent decline in hemoglobin (Hb) levels over time. This decline in Hb levels may depend on individual, unobserved characteristics of the donor. Study Design and Methods We used a data

  14. Oxygen Measurements in Liposome Encapsulated Hemoglobin

    Science.gov (United States)

    Phiri, Joshua Benjamin

    Liposome encapsulated hemoglobins (LEH's) are of current interest as blood substitutes. An analytical methodology for rapid non-invasive measurements of oxygen in artificial oxygen carriers is examined. High resolution optical absorption spectra are calculated by means of a one dimensional diffusion approximation. The encapsulated hemoglobin is prepared from fresh defibrinated bovine blood. Liposomes are prepared from hydrogenated soy phosphatidylcholine (HSPC), cholesterol and dicetylphosphate using a bath sonication method. An integrating sphere spectrophotometer is employed for diffuse optics measurements. Data is collected using an automated data acquisition system employing lock-in -amplifiers. The concentrations of hemoglobin derivatives are evaluated from the corresponding extinction coefficients using a numerical technique of singular value decomposition, and verification of the results is done using Monte Carlo simulations. In situ measurements are required for the determination of hemoglobin derivatives because most encapsulation methods invariably lead to the formation of methemoglobin, a nonfunctional form of hemoglobin. The methods employed in this work lead to high resolution absorption spectra of oxyhemoglobin and other derivatives in red blood cells and liposome encapsulated hemoglobin (LEH). The analysis using singular value decomposition method offers a quantitative means of calculating the fractions of oxyhemoglobin and other hemoglobin derivatives in LEH samples. The analytical methods developed in this work will become even more useful when production of LEH as a blood substitute is scaled up to large volumes.

  15. Keeping Track of Your Blood Sugar

    Science.gov (United States)

    ... glycosylated hemoglobin test (also known as the hemoglobin A1c or HbA1c test) will tell you how you've been ... that has glucose attached to it is called HbA1c. In general, the lower your HbA1c, the better ...

  16. Hemoglobin, hematocrit, and changes in cerebral blood flow: the Second Manifestations of ARTerial disease-Magnetic Resonance study.

    Science.gov (United States)

    van der Veen, Pieternella H; Muller, Majon; Vincken, Koen L; Westerink, Jan; Mali, Willem P T M; van der Graaf, Yolanda; Geerlings, Mirjam I

    2015-03-01

    Hemoglobin and hematocrit are important determinants of blood viscosity and arterial oxygen content and may therefore influence cerebral blood flow (CBF). We examined cross-sectional and prospective associations of hemoglobin and hematocrit with CBF in 569 patients with manifest arterial disease (mean age 57 ± 10 years) with available data on magnetic resonance angiography to measure parenchymal CBF. Mean (SD) parenchymal CBF at baseline was 52.3 (9.8) mL/min/100 mL and decreased with 1.5 (11.0) mL/min/100 mL after on average 3.9 years of follow-up. Linear regression analyses showed that greater hemoglobin and hematocrit values were associated with lower baseline parenchymal CBF and more decline in parenchymal CBF over time, independent of cardiovascular risk factors, use of antiplatelet drugs, anticoagulants, or diuretics, and brain measures: adjusted mean differences (95% confidence interval [CI]) in decline in parenchymal CBF between patients in the lower and upper quartiles of hemoglobin and hematocrit were -2.48 (95% CI -3.70 to -1.25) and -3.69 (95% CI -5.45 to -1.94) mL/min/100 mL. Higher hemoglobin and hematocrit were associated with lower baseline parenchymal CBF and a greater decline in parenchymal CBF over time, possibly as a result of physiological compensating mechanisms. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Crystallization and preliminary X-ray structural studies of hemoglobin A2 and hemoglobin E, isolated from the blood samples of β-thalassemic patients

    International Nuclear Information System (INIS)

    Dasgupta, Jhimli; Sen, Udayaditya; Choudhury, Debi; Datta, Poppy; Chakrabarti, Abhijit; Chakrabarty, Sudipa Basu; Chakrabarty, Amit; Dattagupta, J.K.

    2003-01-01

    Hemoglobin A 2 (α 2 δ 2 ), a minor (2-3%) component of circulating red blood cells, acts as an anti-sickling agent and its elevated concentration in β-thalassemia is a useful clinical diagnostic. In β-thalassemia major, where there is a failure of β-chain production, HbA 2 acts as the predominant oxygen deliverer. Hemoglobin E, is another common abnormal hemoglobin, caused by splice site mutation in exon 1 of β globin gene, when combines with β-thalassemia, causes severe microcytic anemia. The purification, crystallization, and preliminary structural studies of HbA 2 and HbE are reported here. HbA 2 and HbE are purified by cation exchange column chromatography in presence of KCN from the blood samples of individuals suffering from β-thalassemia minor and Eβ-thalassemia. X-ray diffraction data of HbA 2 and HbE were collected upto 2.1 and 1.73 A, respectively. HbA 2 crystallized in space group P2 1 with unit cell parameters a=54.33 A, b=83.73 A, c=62.87 A, and β=99.80 degree sign whereas HbE crystallized in space group P2 1 2 1 2 1 with unit cell parameters a=60.89 A, b=95.81 A, and c=99.08 A. Asymmetric unit in each case contains one Hb tetramer in R 2 state

  18. Hemoglobin, red blood cell count, hematocrit and derived parameters for diagnosing anemia in elderly males

    International Nuclear Information System (INIS)

    Khan, Z.; Nawaz, M.

    2013-01-01

    Anemia is one of the most common micronutrient deficiency in our community. Nutritional anaemias are caused when there is an inadequate body store of a specific nutrient needed for hemoglobin synthesis. The most common nutrient deficiency is of iron. Therefore, a cross-sectional survey was conducted on the healthy elderly male, aged >= 40 and 77 years (n=60) volunteers in order to assess their blood parameters, such as hemoglobin concentration (Hb), hematocrit (HCT), red blood cell count (RBC), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH) and mean corpuscular hemoglobin concentration (MCHC) for the diagnosis of anemia. The demographic results showed mean values (50.10+-8.79) years for age, 66-68 +- 1.95 inches for height , 71.43 +- 6.43 kg body weight, 98.34+-0.48 degree F body temperature, 124 +- 8.67 systolic blood pressure, 82.17 +- 4.15 diastolic pressure while, The pulse rate was found to be 74.63 +- 7.02/minute. Similarly, mean values for lean body weight (LBW) found to be 49.9+-2.89, ideal body weight (IBW) 60.9 +- 4.49, body surface area (BSA) was 1.8 +- 0.1 m2 whereas, body mass index (BMI) showed mean value 24.9 +- 2.6 kg/m2. More so, overall mean Hb found to be 13.60 g/dl, RBC 4.6 mill/mm3, HCT/PCV 43%, MCV 92.95fl, MCH 29.42 pg and MCHC was found to be 31.73 g/dl. The normal range of Hb for men was 13-17 g/dl and 31.67% of the subjects participated in the study was considered to be anemic showing less Hb than normal range. The volunteers were suggested to improve the dietary habits and to take iron supplements in order to overcome the iron deficiency anemia. (author)

  19. A comparison of blood nitric oxide metabolites and hemoglobin functional properties among diving mammals

    DEFF Research Database (Denmark)

    Fago, Angela; Parraga, Daniel Garcia; Petersen, Elin E

    2017-01-01

    examined oxygen affinity, sensitivity to 2,3-diphosphoglycerate (DPG) and nitrite reductase activity of the hemoglobin (Hb) to search for possible adaptive variations in these functional properties. We found levels of plasma and red blood cells nitrite similar to those reported for terrestrial mammals...... in blood oxygen affinity among diving mammals likely derive from phenotypic variations in red blood cell DPG levels. The nitrite reductase activities of the Hbs were overall slightly higher than that of human Hb, with the Hb of beluga whale, capable of longest dives, having the highest activity. Taken...

  20. Hemoglobin estimation by the HemoCue® portable hemoglobin photometer in a resource poor setting

    Directory of Open Access Journals (Sweden)

    Idriss Ali

    2011-04-01

    Full Text Available Abstract Background In resource poor settings where automated hematology analyzers are not available, the Cyanmethemoglobin method is often used. This method though cheaper, takes more time. In blood donations, the semi-quantitative gravimetric copper sulfate method which is very easy and inexpensive may be used but does not provide an acceptable degree of accuracy. The HemoCue® hemoglobin photometer has been used for these purposes. This study was conducted to generate data to support or refute its use as a point-of-care device for hemoglobin estimation in mobile blood donations and critical care areas in health facilities. Method EDTA blood was collected from study participants drawn from five groups: pre-school children, school children, pregnant women, non-pregnant women and men. Blood collected was immediately processed to estimate the hemoglobin concentration using three different methods (HemoCue®, Sysmex KX21N and Cyanmethemoglobin. Agreement between the test methods was assessed by the method of Bland and Altman. The Intraclass correlation coefficient (ICC was used to determine the within subject variability of measured hemoglobin. Results Of 398 subjects, 42% were males with the overall mean age being 19.4 years. The overall mean hemoglobin as estimated by each method was 10.4 g/dl for HemoCue, 10.3 g/dl for Sysmex KX21N and 10.3 g/dl for Cyanmethemoglobin. Pairwise analysis revealed that the hemoglobin determined by the HemoCue method was higher than that measured by the KX21N and Cyanmethemoglobin. Comparing the hemoglobin determined by the HemoCue to Cyanmethemoglobin, the concordance correlation coefficient was 0.995 (95% CI: 0.994-0.996, p Conclusion Hemoglobin determined by the HemoCue method is comparable to that determined by the other methods. The HemoCue photometer is therefore recommended for use as on-the-spot device for determining hemoglobin in resource poor setting.

  1. A study of membrane protein defects and alpha hemoglobin chains of red blood cells in human beta thalassemia

    International Nuclear Information System (INIS)

    Rouyer-Fessard, P.; Garel, M.C.; Domenget, C.; Guetarni, D.; Bachir, D.; Colonna, P.; Beuzard, Y.

    1989-01-01

    The soluble pool of alpha hemoglobin chains present in blood or bone marrow cells was measured with a new affinity method using a specific probe, beta A hemoglobin chain labeled with [ 3 H]N-ethylmaleimide. This pool of soluble alpha chains was 0.067 ± 0.017% of hemoglobin in blood of normal adult, 0.11 ± 0.03% in heterozygous beta thalassemia and ranged from 0.26 to 1.30% in homozygous beta thalassemia intermedia. This elevated pool of soluble alpha chains observed in human beta thalassemia intermedia decreased 33-fold from a value of 10% of total hemoglobin in bone marrow cells to 0.3% in the most dense red blood cells. The amount of insoluble alpha chains was measured by using the polyacrylamide gel electrophoresis in urea and Triton X-100. In beta thalassemia intermedia the amount of insoluble alpha chains was correlated with the decreased spectrin content of red cell membrane and was associated with a decrease in ankyrin and with other abnormalities of the electrophoretic pattern of membrane proteins. The loss and topology of the reactive thiol groups of membrane proteins was determined by using [ 3 H]N-ethylmaleimide added to membrane ghosts prior to urea and Triton X-100 electrophoresis. Spectrin and ankyrin were the major proteins with the most important decrease of thiol groups

  2. The effects of mindfulness eating and yoga exercise on blood sugar levels of pregnant women with gestational diabetes mellitus.

    Science.gov (United States)

    Youngwanichsetha, Sununta; Phumdoung, Sasitorn; Ingkathawornwong, Thitiporn

    2014-11-01

    This randomized controlled trial was carried out to investigate the effect of mindfulness eating and yoga exercise on blood sugar levels among pregnant Thai women with GDM. Interventions promoting achievement of good glycemic control result in desired pregnancy outcomes. Little is known about the health benefits of mindfulness eating and yoga exercise on blood sugar levels among pregnant with GDM. A randomized controlled trial was carried out. Main outcome measures were capillary fasting plasma glucose, 2-h postprandial blood glucose, and hemoglobin A1c. The intervention group showed significantly reduced fasting plasma glucose, 2-h postprandial blood glucose, and glycosylated hemoglobin (HbA1c) in the intervention group (pMindfulness eating and yoga exercise had health benefits on glycemic control in pregnant women with GDM. It should be recommended in clinical and community health services. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. fasting blood glucose and glycosylated haemoglobin levels

    African Journals Online (AJOL)

    Prince Acheampong

    (HbA1c) levels of diabetes mellitus patients as an index of glycaemic control. It was a prospective case- finding study using laboratory and general practice records. ... range of glycosylated haemoglobins, and the cut-off values for some clinical .... quality of glycaemic control by glycated haemoglobin in out-patient diabetic ...

  4. Post-transfusion hemoglobin values and patient blood management

    DEFF Research Database (Denmark)

    Moerman, Jan; Vermeulen, Edith; Van Mullem, Mia

    2018-01-01

    Objectives: The objective of this retrospective study was to evaluate the added value of communicating post-transfusion hemoglobin values to clinicians as a strategy to improve RBC utilization in a 500-bed hospital. Methods: The total number of RBC transfusions, the mean number of RBC units...... transfused per patient, the mean pre- and post-transfusion hemoglobin values, the ratio of patients transfused and the ratio of patients with a post-transfusion hemoglobin > 10.5 g/dL were calculated per service and per department for six months. The data were reported to each service and compared...... with the data of the department as peer group. The impact of this communication strategy was evaluated in the following six months. Results: In the six months pre-intervention, the mean post-transfusion hemoglobin value was 9.2 g/dL. Post-transfusion hemoglobin was > 10.5 g/dL in 13.4% of patients (112...

  5. Analytical determination of specific 4,4'-methylene diphenyl diisocyanate hemoglobin adducts in human blood.

    Science.gov (United States)

    Gries, Wolfgang; Leng, Gabriele

    2013-09-01

    4,4'-Methylene diphenyl diisocyanate (MDI) is one of the most important isocyanates in the industrial production of polyurethane and other MDI-based synthetics. Because of its high reactivity, it is known as a sensitizing agent, caused by protein adducts. Analysis of MDI is routinely done by determination of the nonspecific 4,4'-methylenedianiline as a marker for MDI exposure in urine and blood. Since several publications have reported specific adducts of MDI and albumin or hemoglobin, more information about their existence in humans is necessary. Specific adducts of MDI and hemoglobin were only reported in rats after high-dose MDI inhalation. The aim of this investigation was to detect the hemoglobin adduct 5-isopropyl-3-[4-(4-aminobenzyl)phenyl]hydantoin (ABP-Val-Hyd) in human blood for the first time. We found values up to 5.2 ng ABP-Val-Hyd/g globin (16 pmol/g) in blood samples of workers exposed to MDI. Because there was no information available about possible amounts of this specific MDI marker, the analytical method focused on optimal sensitivity and selectivity. Using gas chromatography-high-resolution mass spectrometry with negative chemical ionization, we achieved a detection limit of 0.02 ng ABP-Val-Hyd/g globin (0.062 pmol/g). The robustness of the method was confirmed by relative standard deviations between 3.0 and 9.8 %. Combined with a linear detection range up to 10 ng ABP-Val-Hyd/g globin (31 pmol/g), the enhanced precision parameter demonstrates that the method described is optimized for screening studies of the human population.

  6. Comparative study of bedside and laboratory measurements of hemoglobin.

    Science.gov (United States)

    Krenzischek, D A; Tanseco, F V

    1996-11-01

    The purpose of this study was to examine the effects of variations in technique on measurements of hemoglobin level done at the bedside and to compare these results with laboratory measurements of hemoglobin. In accordance with hospital policy, procedure, and protocol, various techniques were used to obtain samples of capillary and venous blood and of blood from arterial and central venous catheters. Levels of hemoglobin were measured at the bedside and in the laboratory, and the results were compared. The Johns Hopkins Hospital adult postanesthesia care unit. A total of 187 blood samples were obtained from 62 adults who had undergone general surgery. Group I comprised 20 subjects with capillary and venous blood samples. Group II comprised 21 subjects with arterial blood samples. Group III comprised 21 subjects with central venous blood samples. The results showed that the amount of blood to be discarded before obtaining samples of arterial and central venous blood need not be any larger than double the dead space of the catheter, and that shaking the blood sample for 10 seconds was sufficient to mix the sample before measurement of hemoglobin levels. Results of bedside and laboratory measurements of hemoglobin level were comparable. Bedside measurement of hemoglobin increases efficiency in patient care, decreases risk of blood-transmitted infection for staff, and decreases cost to the patient. However, the persons who perform the assay must be responsible in adhering to the standard of practice to minimize errors in the measurements.

  7. [Hemogram profile and interest of pre-donation hemoglobin measurement in blood donors in the northwest region of Morocco].

    Science.gov (United States)

    Bakrim, S; Ouarour, A; Jaidann, K; Benajiba, M; Masrar, A

    2018-02-01

    Blood donation in Morocco and more particularly in the northwest region is carried out without prior determination of the pre-donation hemoglobin. In addition, we note the lack of scientific research that reports data on the red blood cells, leukocytes and platelet lines in donated blood at the regional or even national level. To study hemogram profile in blood donors taken from the Northwest region of Morocco in order to provide decision makers of the National Center of Blood Transfusion and Hematology with valid scientific arguments to complete the criteria to donate whole blood, by the hemogram. Prospective study, conducted in 15797 volunteer blood donors (BD) aged between 18 and 60 years, collected during mobile or fixed collections carried out by the Regional Blood Transfusion Center of Tangier and Tetouan from November 2014 to May 2016. The hemogram was performed using a Sysmex KX21N ® and the analysis of the data was done by the software SPSS 20.0. According to the World Health Organization, anemia corresponds to a hemoglobin level less than 12g/dL in women and less than 13g/dL in men. We found that 14.5 % of women (n=1054) and 3.0 % of men (n=245) were anemic and anemia was hypochromic microcytic in 58,66 % of these BD. Analysis of the white line showed leucopenia in 2.05 % of BD and 807 cases of leukocytosis (5.27 % of BD). Platelet study showed thrombocytopenia in 3.97 % of BD and thrombocytosis in 151BD (0.99 % of cases). This study shows the interest of systematic pre-donation hemoglobin measurement and periodic realization of the hemogram among BD in the Northwest region of Morocco. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  8. Hemoglobin estimation by the HemoCue® portable hemoglobin photometer in a resource poor setting.

    Science.gov (United States)

    Nkrumah, Bernard; Nguah, Samuel Blay; Sarpong, Nimako; Dekker, Denise; Idriss, Ali; May, Juergen; Adu-Sarkodie, Yaw

    2011-04-21

    In resource poor settings where automated hematology analyzers are not available, the Cyanmethemoglobin method is often used. This method though cheaper, takes more time. In blood donations, the semi-quantitative gravimetric copper sulfate method which is very easy and inexpensive may be used but does not provide an acceptable degree of accuracy. The HemoCue® hemoglobin photometer has been used for these purposes. This study was conducted to generate data to support or refute its use as a point-of-care device for hemoglobin estimation in mobile blood donations and critical care areas in health facilities. EDTA blood was collected from study participants drawn from five groups: pre-school children, school children, pregnant women, non-pregnant women and men. Blood collected was immediately processed to estimate the hemoglobin concentration using three different methods (HemoCue®, Sysmex KX21N and Cyanmethemoglobin). Agreement between the test methods was assessed by the method of Bland and Altman. The Intraclass correlation coefficient (ICC) was used to determine the within subject variability of measured hemoglobin. Of 398 subjects, 42% were males with the overall mean age being 19.4 years. The overall mean hemoglobin as estimated by each method was 10.4 g/dl for HemoCue, 10.3 g/dl for Sysmex KX21N and 10.3 g/dl for Cyanmethemoglobin. Pairwise analysis revealed that the hemoglobin determined by the HemoCue method was higher than that measured by the KX21N and Cyanmethemoglobin. Comparing the hemoglobin determined by the HemoCue to Cyanmethemoglobin, the concordance correlation coefficient was 0.995 (95% CI: 0.994-0.996, p < 0.001). The Bland and Altman's limit of agreement was -0.389 - 0.644 g/dl with the mean difference being 0.127 (95% CI: 0.102-0.153) and a non-significant difference in variability between the two measurements (p = 0.843). After adjusting to assess the effect of other possible confounders such as sex, age and category of person, there was no

  9. A novel type of electrochemical sensor based on ferromagnetic carbon-encapsulated iron nanoparticles for direct determination of hemoglobin in blood samples.

    Science.gov (United States)

    Matysiak, Edyta; Donten, Mikolaj; Kowalczyk, Agata; Bystrzejewski, Michal; Grudzinski, Ireneusz P; Nowicka, Anna M

    2015-02-15

    An effective, fast, facile and direct electrochemical method of determination of hemoglobin (Hb) in blood sample without any sample preparation is described. The method is accomplished by using the ferromagnetic electrode modifier (carbon-encapsulated iron nanoparticles) and an external magnetic field. The successful voltammetric determination of hemoglobin is achieved in PBS buffer as well as in the whole blood sample. The obtained results show the excellent electroactivity of Hb. The measurements are of high sensitivity and good reproducibility. The detection limit is estimated to be 0.7 pM. The electrochemical determination data were compared with the gravimetric data obtained with a quartz crystal microbalance. The agreement between these results is very good. The changes of the electrode surface morphology before and after Hb detection are monitored by electron microscopy. The functionality of the electrochemical sensor is tested with human and rat blood samples. The concentration of hemoglobin in the blood samples determined by using voltammetric/gravimetric detection is in perfect agreement with the data obtained from typical clinical analysis. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. A coordination polymer based magnetic adsorbent material for hemoglobin isolation from human whole blood, highly selective and recoverable

    Science.gov (United States)

    Zhang, Xiaoxing; Tan, Jipeng; Xu, Xinxin; Shi, Fanian; Li, Guanglu; Yang, Yiqiao

    2017-09-01

    A composite material has been obtained successfully through the loading of nanoscale coordination polymer on magnetic Fe3O4@SiO2 core-shell particle. In this composite material, coordination polymer nanoparticles distribute uniformly on Fe3O4@SiO2 and these two components are "tied" together firmly with chemical bonds. Adsorption experiments suggest this composite material exhibits very excellent selectivity to hemoglobin. But under the same condition, its adsorption to bovine serum albumin can almost be ignored. This selectivity can be attributed to the existence of hydrophobic interactions between coordination polymer nanoparticle and hemoglobin. For composite material, the hemoglobin adsorption process follows Langmuir model perfectly with high speed. The adsorbed hemoglobin can be eluted easily by sodium dodecyl sulfate stripping reagent with structure and biological activity of hemoglobin keeps well. The composite material was also employed to separate hemoglobin from human whole blood, which receives a very satisfactory result. Furthermore, magnetic measurement reveals ferromagnetic character of this composite material with magnetization saturation 3.56 emu g-1 and this guarantees its excellent magnetic separation performance from the treated solution.

  11. Associations between long-term exposure to air pollution, glycosylated hemoglobin and diabetes.

    Science.gov (United States)

    Honda, Trenton; Pun, Vivian C; Manjourides, Justin; Suh, Helen

    2017-10-01

    Air pollution exposures have been shown to adversely impact health through a number of biological pathways associated with glucose metabolism. However, few studies have evaluated the associations between air pollution and glycosylated hemoglobin (HbA1c) levels. Further, no studies have evaluated these associations in US populations or investigated whether associations differ in diabetic as compared to non-diabetic populations. To address this knowledge gap, we investigated the associations between airborne fine particulate matter (PM 2.5 ) and nitrogen dioxide (NO 2 ) and HbA1c levels in both diabetic and non-diabetic older Americans. We also examined the impact of PM 2.5 and NO 2 on prevalent diabetes mellitus (DM) in this cohort. We used multilevel logistic and linear regression models to evaluate the association between long-term average air pollutant levels and prevalence of DM and HbA1c levels, respectively, among 4121 older (57+ years) Americans enrolled in the National Social Life, Health, and Aging Project between 2005 and 2011. All models adjusted for age, sex, body mass index, smoking status, race, household income, education level, neighborhood socioeconomic status, geographic region, urbanicity and diabetic medication use. We estimated participant-specific exposures to PM 2.5 on a six-kilometer grid covering the conterminous U.S. using spatio-temporal models, and to NO 2 using nearest measurements from the Environmental Protection Agency's Air Quality System. HbA1c levels were measured for participants in each of two data collection waves from dried blood spots and log-transformed prior to analysis. Participants were considered diabetic if they had HbA1c values≥6.5% or reported taking diabetic medication. The prevalence of diabetes at study entry was 22.2% (n=916) and the mean HbA1c was 6.0±1.1%. Mean one-year moving average PM 2.5 and NO 2 exposures were 10.4±3.0μg/m 3 and 13.1±7.0 ppb, respectively. An inter-quartile range (IQR, 3.9μg/m 3

  12. Effects of Hemoglobin-Based Oxygen Carriers on Blood Coagulation

    Directory of Open Access Journals (Sweden)

    Kimia Roghani

    2014-12-01

    Full Text Available For many decades, Hemoglobin-based oxygen carriers (HBOCs have been central in the development of resuscitation agents that might provide oxygen delivery in addition to simple volume expansion. Since 80% of the world population lives in areas where fresh blood products are not available, the application of these new solutions may prove to be highly beneficial (Kim and Greenburg 2006. Many improvements have been made to earlier generation HBOCs, but various concerns still remain, including coagulopathy, nitric oxide scavenging, platelet interference and decreased calcium concentration secondary to volume expansion (Jahr et al. 2013. This review will summarize the current challenges faced in developing HBOCs that may be used clinically, in order to guide future research efforts in the field.

  13. FORMATION OF HEMOGLOBIN AND ALBUMIN ADDUCTS OF BENZENE OXIDE IN MOUSE, RAT, AND HUMAN BLOOD

    Science.gov (United States)

    Little is known about the formation and disposition of benzene oxide (BO), the initial metabolite arising from oxidation of benzene by cytochrome P450. In this study, reactions of BO with hemoglobin (Hb) and albumin (Alb) were investigated in blood from B6C3F1 mice, F344 rats, ...

  14. Effect of Repeated Whole Blood Donations on Aerobic Capacity and Hemoglobin Mass in Moderately Trained Male Subjects: A Randomized Controlled Trial.

    Science.gov (United States)

    Meurrens, Julie; Steiner, Thomas; Ponette, Jonathan; Janssen, Hans Antonius; Ramaekers, Monique; Wehrlin, Jon Peter; Vandekerckhove, Philippe; Deldicque, Louise

    2016-12-01

    The aims of the present study were to investigate the impact of three whole blood donations on endurance capacity and hematological parameters and to determine the duration to fully recover initial endurance capacity and hematological parameters after each donation. Twenty-four moderately trained subjects were randomly divided in a donation (n = 16) and a placebo (n = 8) group. Each of the three donations was interspersed by 3 months, and the recovery of endurance capacity and hematological parameters was monitored up to 1 month after donation. Maximal power output, peak oxygen consumption, and hemoglobin mass decreased (p donation with a maximal decrease of 4, 10, and 7%, respectively. Hematocrit, hemoglobin concentration, ferritin, and red blood cell count (RBC), all key hematological parameters for oxygen transport, were lowered by a single donation (p donations (p donation was 11% for hematocrit, 10% for hemoglobin concentration, 50% for ferritin, and 12% for RBC (p donation group. Maximal, but not submaximal, endurance capacity was altered after blood donation in moderately trained people and the expected increase in capacity after multiple maximal exercise tests was not present when repeating whole blood donations.

  15. Tranexamic acid administration to older patients undergoing primary total hip arthroplasty conserves hemoglobin and reduces blood loss.

    Science.gov (United States)

    El Beheiry, Hossam; Lubberdink, Ashley; Clements, Nigel; Dihllon, Kiran; Sharma, Vicky

    2018-06-01

    Tranexamic acid effects in older people are difficult to predict. This study investigated the following research questions: 1) Is tranexamic acid effective in older patients undergoing primary total hip arthroplasty (THA)? and 2) Is there a difference in the effect of tranexamic acid between younger and older patients? This was a 2-phase retrospective matched-pair study of patients who underwent THA in 2007-2013. All procedures were performed by surgeons with at least 10 years' experience as senior consultant. In the first phase, 58 patients aged 65 years or more who received tranexamic acid were matched 1:1 with patients who did not receive tranexamic acid for age, sex, American Society of Anesthesiologists (ASA) classification and body mass index. In the second phase, 58 patients aged 65 years or more who received tranexamic acid were matched 1:1 with patients less than 65 years of age who received tranexamic acid for sex, ASA classification and body mass index. The primary outcome measures were percent maximum decrease in hemoglobin level and estimated blood loss after surgery. In the first phase, patients who received tranexamic acid conserved postoperative hemoglobin by a mean of 10.26 g/L (standard deviation [SD] 9.89 g/L) compared to the control group ( p Tranexamic acid reduced the postoperative decrease in hemoglobin level and blood loss in older patients. Moreover, the significant hemoglobin-sparing effect of tranexamic acid in older patients was similar to that observed in younger patients.

  16. Analysis of bias in measurements of potassium, sodium and hemoglobin by an emergency department-based blood gas analyzer relative to hospital laboratory autoanalyzer results.

    Directory of Open Access Journals (Sweden)

    Jian Bo Zhang

    Full Text Available The emergency departments (EDs of Chinese hospitals are gradually being equipped with blood gas machines. These machines, along with the measurement of biochemical markers by the hospital laboratory, facilitate the care of patients with severe conditions who present to the ED. However, discrepancies have been noted between the Arterial Blood Gas (ABG analyzers in the ED and the hospital laboratory autoanalyzer in relation to electrolyte and hemoglobin measurements. The present study was performed to determine whether the ABG and laboratory measurements of potassium, sodium, and hemoglobin levels are equivalent, and whether ABG analyzer results can be used to guide clinical care before the laboratory results become available.Study power analyses revealed that 200 consecutive patients who presented to our ED would allow this prospective single-center cohort study to detect significant differences between ABG- and laboratory-measured potassium, sodium, and hemoglobin levels. Paired arterial and venous blood samples were collected within 30 minutes. Arterial blood samples were measured in the ED by an ABL 90 FLEX blood gas analyzer. The biochemistry and blood cell counts of the venous samples were measured in the hospital laboratory. The potassium, sodium, and hemoglobin concentrations obtained by both methods were compared by using paired Student's t-test, Spearman's correlation, Bland-Altman plots, and Deming regression.The mean ABG and laboratory potassium values were 3.77±0.44 and 4.2±0.55, respectively (P<0.0001. The mean ABG and laboratory sodium values were 137.89±5.44 and 140.93±5.50, respectively (P<0.0001. The mean ABG and laboratory Hemoglobin values were 12.28±2.62 and 12.35±2.60, respectively (P = 0.24.Although there are the statistical difference and acceptable biases between ABG- and laboratory-measured potassium and sodium, the biases do not exceed USCLIA-determined limits. In parallel, there are no statistical differences and

  17. [Effect of meal frequency and carbohydrate intake on the metabolic control of patients with type 2 diabetes mellitus].

    Science.gov (United States)

    Leiva, Tamara; Basfi-Fer, Karen; Rojas, Pamela; Carrasco, Fernando; Ruz O, Manuel

    2016-10-01

    Increasing meal frequency is commonly used in the clinical practice as part of the nutritional treatment of patients with type 2 Diabetes Mellitus (DM2), although its effect on metabolic control parameters is controversial. To evaluate the association of energy intake, meal frequency, and amount of carbohydrates with fasting plasma glucose and glycosylated hemoglobin in a group of patients with DM2 without insulin therapy. Dietary intake was evaluated in 60 subjects with DM2 through three-day food records. The meal frequency was estimated establishing the main meal times considering snacks. Meal frequency was 4.7 ± 1.1 times per day. There was a positive association between glycosylated and fasting blood glucose levels (p Meal frequency was associated with energy intake (p meal frequency, available carbohydrates and energy intake, body mass index and fasting plasma glucose were analyzed in a multiple linear regression model, fasting blood glucose was the variable that best predicted changes in glycosylated hemoglobin (45.5%). Meal frequency had no association with glycosylated hemoglobin. Meal frequency showed no association with metabolic control parameters in DM2 patients.

  18. Effects of blood glucose, blood lipids and blood pressure control on recovery of patients with gastric cancer complicated with metabolic syndrome after radical gastrectomy.

    Science.gov (United States)

    Sun, Li; Zhou, Pingping; Hua, Qingli; Jin, Changming; Guo, Chunling; Song, Bing

    2018-06-01

    This study aimed to investigate the effects of blood glucose, blood lipids and blood pressure control on recovery of patients with gastric cancer complicated with metabolic syndrome (MS) after radical gastrectomy. A total of 150 patients with gastric cancer, who were treated in Daqing Longnan Hospital from November, 2015 to May, 2017, were enrolled in this study. The patients were divided into the MS group (80 cases) and non-MS group (70 cases). Patients in the MS group were given corresponding drugs to control blood pressure, blood lipids and blood glucose, while patients in the non-MS group were not treated with those drugs. Patients in the MS group were divided into the normal and abnormal groups according to the levels of blood glucose, blood lipids and blood pressure. Moreover, occurrences of complications were compared between the normal and abnormal groups. Before surgery, blood glucose, blood lipids and blood pressure in the MS group were significantly higher than those in the non-MS group (pblood glucose, blood lipids and blood pressure of the MS group decreased significantly compared to those before operation (pblood glucose, 2 h postprandial blood glucose, glycosylated hemoglobin, total triglycerides (TGs), LDL, mean blood pressure and BMI (pblood glucose, blood lipids and blood pressure in patients with gastric cancer complicated with MS after radical gastrectomy can reduce the incidence of postoperative complications and promote postoperative recovery.

  19. Glycosylated hemoglobin testing in the National Social Life, Health, and Aging Project.

    Science.gov (United States)

    Gregg, Forest T; O'Doherty, Katie; Schumm, L Philip; McClintock, Martha K; Huang, Elbert S

    2014-11-01

    Longitudinal biomeasures of health are still new in nationally representative social science survey research. Data measuring blood sugar control provide opportunities for understanding the development of diabetes and its complications in older adults, but researchers must be aware that some of the differences across time can be due to variations in measurement procedures. This is a well-recognized issue whenever all samples cannot be assayed at the same time and we sought to present the analytic methods to quantify and adjust for the variation. We collected and analyzed HbA1C, glycated hemoglobin, a biomeasure of average blood sugar concentrations within the past few months. Improvements were made in the collection protocol for Wave 2, and assays were performed by a different lab. The HbA1C data obtained during Wave 1 and Wave 2 are consistent with the expected population distributions for differences by gender, age, race/ethnicity, and diabetes status. Age-adjusted mean HbA1C declined slightly from Wave 1 to Wave 2 by -0.19 (95% confidence interval [CI]: -0.27, -0.10), and the average longitudinal change was -0.12 (95% CI: -0.18, -0.06). Collection of HbA1C in Wave 2 permits researchers to examine the relationship between HbA1C and new health and social measures added in Wave 2, and to identify factors related to the change in HbA1C. Changes in collection protocol and labs between waves may have yielded small systematic differences that require analysts to carefully interpret absolute HbA1C values. We recommend analytic methods for cross wave differences in HbA1C and steps to ensure cross wave comparability in future studies. © The Author 2014. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  20. HEMOGLOBINA GLICOSILADA O HEMOGLOBINA GLICADA, ¿CUÁL DE LAS DOS? | GLYCOSILATED HEMOGLOBIN OR GLYCATED HEMOGLOBIN, WHICH OF THE TWO?

    Directory of Open Access Journals (Sweden)

    Mariela Bracho-Nava

    2015-11-01

    , according to the International Federation of Clinical Chemistry (IFCC, as a generic term referring to a group of substances that are formed from biochemical reactions between hemoglobin A (HbA and some reducing sugars present in the bloodstream, glucose being the most abundant of them. This reaction is known as the Maillard reaction, which is based on a non-enzimatic glycosylation, or more correctly called, in a glycation. Custom, ignorance or confusion among both chemical processes has led to use the term glycosylated hemoglobin instead of glycated hemoglobin. This article provides a review of the process of formation of hemoglobin A1c, defining the reaction of glycosylation and the protein glycation, the chemical species that favor the glycation, the characteristics of the process of glycation of hemoglobin, stages in which it occurs and the effects related to the glycation of proteins in human beings, to finally conclude with a passage of designations which has received the HbA1c to the present; all with the aim of clarifying and giving property to the use of the term glycated hemoglobin.

  1. Fish hemoglobins

    Directory of Open Access Journals (Sweden)

    P.C. de Souza

    2007-06-01

    Full Text Available Vertebrate hemoglobin, contained in erythrocytes, is a globular protein with a quaternary structure composed of 4 globin chains (2 alpha and 2 beta and a prosthetic group named heme bound to each one. Having myoglobin as an ancestor, hemoglobin acquired the capacity to respond to chemical stimuli that modulate its function according to tissue requirements for oxygen. Fish are generally submitted to spatial and temporal O2 variations and have developed anatomical, physiological and biochemical strategies to adapt to the changing environmental gas availability. Structurally, most fish hemoglobins are tetrameric; however, those from some species such as lamprey and hagfish dissociate, being monomeric when oxygenated and oligomeric when deoxygenated. Fish blood frequently possesses several hemoglobins; the primary origin of this finding lies in the polymorphism that occurs in the globin loci, an aspect that may occasionally confer advantages to its carriers or even be a harmless evolutionary remnant. On the other hand, the functional properties exhibit different behaviors, ranging from a total absence of responses to allosteric regulation to drastic ones, such as the Root effect.

  2. Action of carbon monoxide on the affinity of hemoglobin for oxygen

    Energy Technology Data Exchange (ETDEWEB)

    Vanuxem, D.; Weiller, P.J.; Guillot, C.; Grimaud, C.

    1982-01-01

    The authors have studied the action of carbon monoxide on the affinity of hemoglobin for oxygen by measuring P50 in whole blood and in stripped hemoglobin before and after exposition of blood samples from heavy smokers and polycythemic patients with high levels of HbCO to hyperbaric oxygen (2.2 ata). The concentration of 2,3-diphosphoglycerate was normal although P50 was significantly lowered, not only in whole blood but also in stripped hemoglobin. Hyperbaric oxygen normalized P50 by removing CO radicals from stripped hemoglobin. This may indicate that CO radicals exert a direct action on the hemoglobin molecule, at least at the HbCO levels studied in this work.

  3. Top-Down Proteomics and Direct Surface Sampling of Neonatal Dried Blood Spots: Diagnosis of Unknown Hemoglobin Variants

    Science.gov (United States)

    Edwards, Rebecca L.; Griffiths, Paul; Bunch, Josephine; Cooper, Helen J.

    2012-11-01

    We have previously shown that liquid microjunction surface sampling of dried blood spots coupled with high resolution top-down mass spectrometry may be used for screening of common hemoglobin variants HbS, HbC, and HbD. In order to test the robustness of the approach, we have applied the approach to unknown hemoglobin variants. Six neonatal dried blood spot samples that had been identified as variants, but which could not be diagnosed by current screening methods, were analyzed by direct surface sampling top-down mass spectrometry. Both collision-induced dissociation and electron transfer dissociation mass spectrometry were employed. Four of the samples were identified as β-chain variants: two were heterozygous Hb D-Iran, one was heterozygous Hb Headington, and one was heterozygous Hb J-Baltimore. The fifth sample was identified as the α-chain variant heterozygous Hb Phnom Penh. Analysis of the sixth sample suggested that it did not in fact contain a variant. Adoption of the approach in the clinic would require speed in both data collection and interpretation. To address that issue, we have compared manual data analysis with freely available data analysis software (ProsightPTM). The results demonstrate the power of top-down proteomics for hemoglobin variant analysis in newborn samples.

  4. Titania nanotubes decorated with gold nanoparticles for electrochemiluminescent biosensing of glycosylated hemoglobin

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Qun [Institute of Analytical Chemistry, Dushu Lake Campus, Soochow University, Industrial Park, Suzhou, 215123 (China); College of Chemistry and Chemical Engineering, Nantong University, Nantong, 226019 (China); Tang, Shan [Institute of Analytical Chemistry, Dushu Lake Campus, Soochow University, Industrial Park, Suzhou, 215123 (China); Fang, Chen [Institute of Analytical Chemistry, Dushu Lake Campus, Soochow University, Industrial Park, Suzhou, 215123 (China); Second Affiliated Hospital, Soochow University, Suzhou, 215004 (China); Tu, Yi-Feng, E-mail: tuyf@suda.edu.cn [Institute of Analytical Chemistry, Dushu Lake Campus, Soochow University, Industrial Park, Suzhou, 215123 (China)

    2016-09-14

    A glycated hemoglobin (HbA1c) biosensor with high performance has been constructed in this work. Here the fructosyl amino acid oxidase was immobilized onto a pre-functionalized indium tin oxide glass with titania nanotubes decorated with gold nanoparticles. The property of nanocomposite was characterized by transmission electromicroscopy, scanning electron microscopy, electrochemistry and spectroscopy. Under the optimum conditions, fructosyl valine was detected by this biosensor. It exhibited a linear detection range from 4.0 × 10{sup −9} M to 7.2 × 10{sup −7} M, and a limit of detection for 3.8 × 10{sup −9} M at the signal-to-noise ratio of 3. Thus the HbA1c level in whole blood samples of healthy individuals or diabetic patients were evaluated with designed biosensor after pre-treatment of hydrolysis. The results of our detection were closely consistent with that of the standard method. At the same time, our biosensor has some advantages including high sensitivity, disposable usage and low cost, which implies its great promising application in point-of-care testing of HbA1c. - Highlights: • The enhanced electrochemiluminescence of luminol by AuNPs/TiNTs. • An ECL biosensor for HbA1c assay with ultra-high sensitivity. • A promising disposable device for diabetic diagnosis and treatment even for POCT. • The excellent regression of detected results with gold-standard method.

  5. Titania nanotubes decorated with gold nanoparticles for electrochemiluminescent biosensing of glycosylated hemoglobin

    International Nuclear Information System (INIS)

    Zhao, Qun; Tang, Shan; Fang, Chen; Tu, Yi-Feng

    2016-01-01

    A glycated hemoglobin (HbA1c) biosensor with high performance has been constructed in this work. Here the fructosyl amino acid oxidase was immobilized onto a pre-functionalized indium tin oxide glass with titania nanotubes decorated with gold nanoparticles. The property of nanocomposite was characterized by transmission electromicroscopy, scanning electron microscopy, electrochemistry and spectroscopy. Under the optimum conditions, fructosyl valine was detected by this biosensor. It exhibited a linear detection range from 4.0 × 10"−"9 M to 7.2 × 10"−"7 M, and a limit of detection for 3.8 × 10"−"9 M at the signal-to-noise ratio of 3. Thus the HbA1c level in whole blood samples of healthy individuals or diabetic patients were evaluated with designed biosensor after pre-treatment of hydrolysis. The results of our detection were closely consistent with that of the standard method. At the same time, our biosensor has some advantages including high sensitivity, disposable usage and low cost, which implies its great promising application in point-of-care testing of HbA1c. - Highlights: • The enhanced electrochemiluminescence of luminol by AuNPs/TiNTs. • An ECL biosensor for HbA1c assay with ultra-high sensitivity. • A promising disposable device for diabetic diagnosis and treatment even for POCT. • The excellent regression of detected results with gold-standard method.

  6. Decreasing the critical value of hemoglobin required for physician notification reduces the rate of blood transfusions

    Directory of Open Access Journals (Sweden)

    Larson EA

    2016-06-01

    Full Text Available Eric A Larson,1 Paul A Thompson,1,2 Zachary K Anderson,3 Keith A Anderson,4 Roxana A Lupu,1 Vicki Tigner,5 Wendell W Hoffman6,7 1Department of Internal Medicine, 2Department of Pediatrics, Sanford School of Medicine, University of South Dakota, Sioux Falls, SD, 3Department of Internal Medicine, Fairview Health Services, Edina, MN, 4Department of Laboratory Medicine, Sanford School of Medicine, University of South Dakota, 5Medical Staff Services, 6Department of Infectious Disease, Sanford Health, Sanford USD Medical Center, 7Department of Infectious Disease, Sanford School of Medicine, University of South Dakota, Sioux Falls, SD, USAAbstract: Red blood cell transfusions have been cited as one of the most overused therapeutic interventions in the USA. Excessively aggressive transfusion practices may be driven by mandatory physician notification of critical hemoglobin values that do not generally require transfusion. We examined the effect of decreasing the critical value of hemoglobin from 8 to 7 g/dL at our institution. Along with this change, mandatory provider notification for readings between 7 and 8 g/dL was rescinded. Transfusion rates were compared retrospectively during paired 5-month periods for patients presenting in three key hemoglobin ranges (6.00–6.99, 7.00–7.99, and 8.00–8.99 g/dL. A change in transfusion practices was hypothesized in the 7–8 g/dL range, which was no longer labeled critical and for which mandated physician calls were rescinded. Transfusion rates showed a statistically significant 8% decrease (P≤0.0001 during the 5-month period post change in our transfusion practices. This decrease in the 7.00–7.99 g/dL range was significantly greater than the 2% decrease observed in either the 6–6.99 g/dL (P=0.0017 or 8–8.99 g/dL (P≤0.0001 range. Cost savings of up to $700,000/year were extrapolated from our results showing 491 fewer units of red blood cells transfused during the 5-month post change. These cost

  7. Point-of-care blood gases, electrolytes, chemistries, hemoglobin, and hematocrit measurement in venous samples from pet rabbits.

    Science.gov (United States)

    Selleri, Paolo; Di Girolamo, Nicola

    2014-01-01

    Point-of-care testing is an attractive option in rabbit medicine, because it permits rapid analysis of a panel of electrolytes, chemistries, blood gases, hemoglobin, and hematocrit, requiring only 65 μL of blood. The purpose of this study was to evaluate the performance of a portable clinical analyzer for measurement of pH, partial pressure of CO2, Na, chloride, potassium, blood urea nitrogen, glucose, hematocrit, and hemoglobin in healthy and diseased rabbits. Blood samples obtained from 30 pet rabbits were analyzed immediately after collection by the portable clinical analyzer (PCA) and immediately thereafter (time <20 sec) by a reference analyzer. Bland-Altman plots and Passing-Bablok regression analysis were used to compare the results. Limits of agreement were wide for all the variables studied, with the exception of pH. Most variables presented significant proportional and/or constant bias. The current study provides sufficient evidence that the PCA presents reliability for pH, although its low agreement with a reference analyzer for the other variables does not support their interchangeability. Limits of agreement provided for each variable allow researchers to evaluate if the PCA is reliable enough for their scope. To the authors' knowledge, the present is the first report evaluating a PCA in the rabbit.

  8. Glycosylation Engineering

    DEFF Research Database (Denmark)

    Clausen, Henrik; Wandall, Hans H.; Steentoft, Catharina

    2017-01-01

    Knowledge of the cellular pathways of glycosylation across phylogeny provides opportunities for designing glycans via genetic engineering in a wide variety of cell types including bacteria, fungi, plant cells, and mammalian cells. The commercial demand for glycosylation engineering is broad......, including production of biological therapeutics with defined glycosylation (Chapter 57). This chapter describes how knowledge of glycan structures and their metabolism (Parts I–III of this book) has led to the current state of glycosylation engineering in different cell types. Perspectives for rapid...

  9. The role of glycosylation in breast cancer metastasis and cancer control

    Directory of Open Access Journals (Sweden)

    Alexandra eKölbl

    2015-10-01

    Full Text Available AbstractGlycosylation and its correlation to the formation of remote metastasis in breast cancer had been an important scientific topic in the last 25 years. With the development of new analytical techniques new insights were gained on the mechanisms underlying metastasis formation and the role of aberrant glycosylation within. Mucin-1 and Galectin were recognized as key players in glycosylation. Interestingly, aberrant carbohydrate structures seem to support the development of brain metastasis in breast cancer patients, as changes in glycosylation structures facilitate an overcoming of blood-brain barrier. Changes in the gene expression of glycosyltransferases are the leading cause for a modification of carbohydrate chains, so that also altered gene expression plays a role for glycosylation. In consequence, glycosylation and changes within can be useful for cancer diagnosis, determination of tumour stage and prognosis, but can as well be targets for therapeutic strategies. Thus, further research on this topic would worth wile for cancer combating.

  10. Respiratory adaptations in carp blood. Influences of hypoxia, red cell organic phosphates, divalent cations and CO2 on hemoglobin-oxygen affinity

    DEFF Research Database (Denmark)

    Weber, Roy E.; Lykkeboe, G.

    1978-01-01

    This study concerns the adaptation of oxygen transporting function of carp blood to environment hypoxia, tracing the roles played by erythrocytic cofactors, inorganic cations, carbon dioxide and hemoglobin multiplicity. Carp acclimated to hypoxia ( 30 mmHg) display striking increases in blood oxy...

  11. High-affinity hemoglobin and blood oxygen saturation in diving emperor penguins.

    Science.gov (United States)

    Meir, Jessica U; Ponganis, Paul J

    2009-10-01

    The emperor penguin (Aptenodytes forsteri) thrives in the Antarctic underwater environment, diving to depths greater than 500 m and for durations longer than 23 min. To examine mechanisms underlying the exceptional diving ability of this species and further describe blood oxygen (O2) transport and depletion while diving, we characterized the O2-hemoglobin (Hb) dissociation curve of the emperor penguin in whole blood. This allowed us to (1) investigate the biochemical adaptation of Hb in this species, and (2) address blood O2 depletion during diving, by applying the dissociation curve to previously collected partial pressure of O2 (PO2) profiles to estimate in vivo Hb saturation (SO2) changes during dives. This investigation revealed enhanced Hb-O2 affinity (P50=28 mmHg, pH 7.5) in the emperor penguin, similar to high-altitude birds and other penguin species. This allows for increased O2 at low blood PO2 levels during diving and more complete depletion of the respiratory O2 store. SO2 profiles during diving demonstrated that arterial SO2 levels are maintained near 100% throughout much of the dive, not decreasing significantly until the final ascent phase. End-of-dive venous SO2 values were widely distributed and optimization of the venous blood O2 store resulted from arterialization and near complete depletion of venous blood O2 during longer dives. The estimated contribution of the blood O2 store to diving metabolic rate was low and highly variable. This pattern is due, in part, to the influx of O2 from the lungs into the blood during diving, and variable rates of tissue O2 uptake.

  12. Point-of-care hemoglobin testing for postmortem diagnosis of anemia.

    Science.gov (United States)

    Na, Joo-Young; Park, Ji Hye; Choi, Byung Ha; Kim, Hyung-Seok; Park, Jong-Tae

    2018-03-01

    An autopsy involves examination of a body using invasive methods such as dissection, and includes various tests using samples procured during dissection. During medicolegal autopsies, the blood carboxyhemoglobin concentration is commonly measured using the AVOXimeter® 4000 as a point-of-care test. When evaluating the body following hypovolemic shock, characteristics such as reduced livor mortis or an anemic appearance of the viscera can be identified, but these observations arequite subjective. Thus, a more objective test is required for the postmortem diagnosis of anemia. In the present study, the AVOXimeter® 4000 was used to investigate the utility of point-of-care hemoglobin testing. Hemoglobin tests were performed in 93 autopsy cases. The AVOXimeter® 4000 and the BC-2800 Auto Hematology Analyzer were used to test identical samples in 29 of these cases. The results of hemoglobin tests performed with these two devices were statistically similar (r = 0.969). The results of hemoglobin tests using postmortem blood were compared with antemortem test results from medical records from 31 cases, and these results were similar. In 13 of 17 cases of death from internal hemorrhage, hemoglobin levels were lower in the cardiac blood than in blood from the affected body cavity, likely due to compensatory changes induced by antemortem hemorrhage. It is concluded that blood hemoglobin testing may be useful as a point-of-care test for diagnosing postmortem anemia.

  13. Lyophilized bovine hemoglobin as a possible reference material for the determination of hemoglobin derivatives in human blood

    NARCIS (Netherlands)

    Maas, BHA; Buursma, A; Ernst, RAJ; Maas, AHJ; Zijlstra, WG

    We investigated the suitability of a lyophilized bovine hemoglobin (LBH) preparation containing various fractions of oxyhemoglobin (O(2)Hb), carboxyhemoglobin (COHb), and methemoglobin (MetHb) for quality assessment in multicomponent analysis (MCA) of hemoglobin derivatives. It was demonstrated that

  14. Lyophilized bovine hemoglobin as a possible reference material for the determination of hemoglobin derivatives in human blood

    NARCIS (Netherlands)

    Maas, BHA; Buursma, A; Ernst, RAJ; Maas, AHJ; Zijlstra, WG

    1998-01-01

    We investigated the suitability of a lyophilized bovine hemoglobin (LBH) preparation containing various fractions of oxyhemoglobin (O(2)Hb), carboxyhemoglobin (COHb), and methemoglobin (MetHb) for quality assessment in multicomponent analysis (MCA) of hemoglobin derivatives. It was demonstrated that

  15. Optical wavelength selection for portable hemoglobin determination by near-infrared spectroscopy method

    Science.gov (United States)

    Tian, Han; Li, Ming; Wang, Yue; Sheng, Dinggao; Liu, Jun; Zhang, Linna

    2017-11-01

    Hemoglobin concentration is commonly used in clinical medicine to diagnose anemia, identify bleeding, and manage red blood cell transfusions. The golden standard method for determining hemoglobin concentration in blood requires reagent. Spectral methods were advantageous at fast and non-reagent measurement. However, model calibration with full spectrum is time-consuming. Moreover, it is necessary to use a few variables considering size and cost of instrumentation, especially for a portable biomedical instrument. This study presents different wavelength selection methods for optical wavelengths for total hemoglobin concentration determination in whole blood. The results showed that modelling using only two wavelengths combination (1143 nm, 1298 nm) can keep on the fine predictability with full spectrum. It appears that the proper selection of optical wavelengths can be more effective than using the whole spectra for determination hemoglobin in whole blood. We also discussed the influence of water absorptivity on the wavelength selection. This research provides valuable references for designing portable NIR instruments determining hemoglobin concentration, and may provide some experience for noninvasive hemoglobin measurement by NIR methods.

  16. Techniques used for the screening of hemoglobin levels in blood donors: current insights and future directions

    Directory of Open Access Journals (Sweden)

    Chaudhary R

    2017-07-01

    Full Text Available Rajendra Chaudhary,1 Anju Dubey,2 Atul Sonker3 1Department of Transfusion Medicine, Sanjay Gandhi Postgraduate Institute of Medical Sciences, 2Department of Transfusion Medicine, T.S. Misra Medical College and Hospital, 3Department of Transfusion Medicine, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, India Abstract: Blood donor hemoglobin (Hb estimation is an important donation test that is performed prior to blood donation. It serves the dual purpose of protecting the donors’ health against anemia and ensuring good quality of blood components, which has an implication on recipients’ health. Diverse cutoff criteria have been defined world over depending on population characteristics; however, no testing methodology and sample requirement have been specified for Hb screening. Besides the technique, there are several physiological and methodological factors that affect accuracy and reliability of Hb estimation. These include the anatomical source of blood sample, posture of the donor, timing of sample and several other biological factors. Qualitative copper sulfate gravimetric method has been the archaic time-tested method that is still used in resource-constrained settings. Portable hemoglobinometers are modern quantitative devices that have been further modified to reagent-free cuvettes. Furthermore, noninvasive spectrophotometry was introduced, mitigating pain to blood donor and eliminating risk of infection. Notwithstanding a tremendous evolution in terms of ease of operation, accuracy, mobility, rapidity and cost, a component of inherent variability persists, which may partly be attributed to pre-analytical variables. Hence, blood centers should pay due attention to validation of test methodology, competency of operating staff and regular proficiency testing of the outputs. In this article, we have reviewed various regulatory guidelines, described the variables that affect the measurements and compared the validated

  17. Modification of hemoglobin level and hematocrit value in the peripheral blood of mice after 45Ca internal irradiation by MPG (2-mercaptopropionylglycine)

    International Nuclear Information System (INIS)

    Bhagat, R.M.; Kumar, A.

    1986-01-01

    Radioprotective effect of MPG has been studied on the hemoglobin level and hematocrit value of peripheral blood of Swiss albino mice against radiation-induced changes after injecting radiocalcium ( 45 Ca) at the dose level of 37 kBq/g body weight. MPG was injected 15-30 minutes before 45 Ca injection at dose of 20 mg/kg body weight intraperitoneally and also MPG was injected at various repeated doses. It has been observed that MPG in repeated doses is effective in reducing the radiation-induced changes in the hemoglobin and hematocrit value of peripheral blood of Swiss albino mice following 45 Ca internal irradiation. (author)

  18. Diagnostic accuracy of urinary prostate protein glycosylation profiling in prostatitis diagnosis.

    Science.gov (United States)

    Vermassen, Tijl; Van Praet, Charles; Poelaert, Filip; Lumen, Nicolaas; Decaestecker, Karel; Hoebeke, Piet; Van Belle, Simon; Rottey, Sylvie; Delanghe, Joris

    2015-01-01

    Although prostatitis is a common male urinary tract infection, clinical diagnosis of prostatitis is difficult. The developmental mechanism of prostatitis is not yet unraveled which led to the elaboration of various biomarkers. As changes in asparagine-linked-(N-)-glycosylation were observed between healthy volunteers (HV), patients with benign prostate hyperplasia and prostate cancer patients, a difference could exist in biochemical parameters and urinary N-glycosylation between HV and prostatitis patients. We therefore investigated if prostatic protein glycosylation could improve the diagnosis of prostatitis. Differences in serum and urine biochemical markers and in total urine N-glycosylation profile of prostatic proteins were determined between HV (N=66) and prostatitis patients (N=36). Additionally, diagnostic accuracy of significant biochemical markers and changes in N-glycosylation was assessed. Urinary white blood cell (WBC) count enabled discrimination of HV from prostatitis patients (Pprostatitis patients from HV (Pprostatitis patients compared to HV (Pprostatitis. Further research is required to unravel the developmental course of prostatic inflammation.

  19. Effect of an aqueous extract of Scoparia dulcis on blood glucose, plasma insulin and some polyol pathway enzymes in experimental rat diabetes.

    Science.gov (United States)

    Latha, M; Pari, L

    2004-04-01

    The effects of an aqueous extract of the plant Scoparia dulcis (200 mg/kg) on the polyol pathway and lipid peroxidation were examined in the liver of streptozotocin adult diabetic male albino Wistar rats. The diabetic control rats (N = 6) presented a significant increase in blood glucose, sorbitol dehydrogenase, glycosylated hemoglobin and lipid peroxidation markers such as thiobarbituric acid reactive substances (TBARS) and hydroperoxides, and a significant decrease in plasma insulin and antioxidant enzymes such as glutathione peroxidase (GPx), glutathione-S-transferase (GST) and reduced glutathione (GSH) compared to normal rats (N = 6). Scoparia dulcis plant extract (SPEt, 200 mg kg-1 day-1) and glibenclamide (600 microg kg-1 day-1), a reference drug, were administered by gavage for 6 weeks to diabetic rats (N = 6 for each group) and significantly reduced blood glucose, sorbitol dehydrogenase, glycosylated hemoglobin, TBARS, and hydroperoxides, and significantly increased plasma insulin, GPx, GST and GSH activities in liver. The effect of the SPEt was compared with that of glibenclamide. The effect of the extract may have been due to the decreased influx of glucose into the polyol pathway leading to increased activities of antioxidant enzymes and plasma insulin and decreased activity of sorbitol dehydrogenase. These results indicate that the SPEt was effective in attenuating hyperglycemia in rats and their susceptibility to oxygen free radicals.

  20. Effect of an aqueous extract of Scoparia dulcis on blood glucose, plasma insulin and some polyol pathway enzymes in experimental rat diabetes

    Directory of Open Access Journals (Sweden)

    M. Latha

    2004-04-01

    Full Text Available The effects of an aqueous extract of the plant Scoparia dulcis (200 mg/kg on the polyol pathway and lipid peroxidation were examined in the liver of streptozotocin adult diabetic male albino Wistar rats. The diabetic control rats (N = 6 presented a significant increase in blood glucose, sorbitol dehydrogenase, glycosylated hemoglobin and lipid peroxidation markers such as thiobarbituric acid reactive substances (TBARS and hydroperoxides, and a significant decrease in plasma insulin and antioxidant enzymes such as glutathione peroxidase (GPx, glutathione-S-transferase (GST and reduced glutathione (GSH compared to normal rats (N = 6. Scoparia dulcis plant extract (SPEt, 200 mg kg-1 day-1 and glibenclamide (600 µg kg-1 day-1, a reference drug, were administered by gavage for 6 weeks to diabetic rats (N = 6 for each group and significantly reduced blood glucose, sorbitol dehydrogenase, glycosylated hemoglobin, TBARS, and hydroperoxides, and significantly increased plasma insulin, GPx, GST and GSH activities in liver. The effect of the SPEt was compared with that of glibenclamide. The effect of the extract may have been due to the decreased influx of glucose into the polyol pathway leading to increased activities of antioxidant enzymes and plasma insulin and decreased activity of sorbitol dehydrogenase. These results indicate that the SPEt was effective in attenuating hyperglycemia in rats and their susceptibility to oxygen free radicals.

  1. Association between effort-reward imbalance and glycosylated hemoglobin (HbA1c) among Chinese workers: results from SHISO study.

    Science.gov (United States)

    Xu, Weixian; Hang, Juan; Gao, Wei; Zhao, Yiming; Li, Weihong; Wang, Xinyu; Li, Zhaoping; Guo, Lijun

    2012-02-01

    The studies focusing on effort-reward imbalance and diabetes mellitus (DM)/glycosylated hemoglobin (HbA1c) are rare. We sought to examine the association between job stress evaluated by effort-reward imbalance (ERI) model and HbA1c in a Chinese population. We analyzed 680 subjects (465 men and 215 women) without DM or impaired glucose tolerance from the stress and health in Shenzhen workers (SHISO) study. Job stress was evaluated by effort-reward imbalance (ERI) model. HbA1c was measured by an automatic analyzer by means of high-performance liquid chromatography. The association between job stress and HbA1c was explored by variance analysis, partial correlations and multiple linear regression analysis. For women, effort, and ERI were positively associated with HbA1c (r = 0.22, p = 0,003; r = 0.21, p = 0.006, respectively), in contrast, reward was negatively associated with HbA1c (r = -0.17, p = 0.021), after controlling age, BMI and physical exercise in the partial correlation analysis; the similar results were confirmed in the multiple linear regression. No significant correlations between job stress and HbA1c were found for men. Effort and ERI are positively associated with HbA1c, and reward is inversely related to HbA1c among Chinese women. The association is not accounted for by age, BMI, and physical exercise. More efforts should be made to improve the job stress status of Chinese working women for the purpose of DM prevention.

  2. [Levels of glycosylated hemoglobin and the difference in the cost of health care for diabetic patients: an econometric study].

    Science.gov (United States)

    Lenz, Rony; Zarate, Aldo; Rodríguez, Jorge; Ramírez, Jorge

    2014-07-01

    Complications increase treatment costs of diabetes mellitus (DM). An adequate metabolic control of the disease could reduce these costs. To evaluate the costs of medical care for a cohort of patients with DM, according to their degree of metabolic compensation. All diabetic patients attended in a regional hospital from 2005 to 2010 were analyzed. A correlational study between costs of individual healthcare and levels of glycosylated hemoglobin (HbA1c), was performed in a series of annual cross-sectional measurements. The study comprised 1,644 diabetic patients. During the study period the average cost of healthcare per patient increased from $878,000 to more than $1,000,000 Chilean pesos (CLP) during the study period. The percentage of patients with HbA1c levels below 7.0% varied between 43.0% and 54.9%. Costs for patients with HbA1c levels between 7 and 8.9% were 1.3 to 1.5 times greater. For the group of patients with HbA1c levels between 9 and 10.9% the costs increased 1.4 to 1.6 times. For patients with HbA1c levels greater than 11.0%, healthcare costs doubled. Healthcare expenditure varied according to metabolic control, which is consistent with international findings. This study was limited by its selected population, incomplete information on health expenditures, and the inclusion of only direct costs to the health system. If all patients would achieve metabolic compensation, the yearly savings would be CLP $308,000,000 (or USD $657,000).

  3. Is a blood sample for hemoglobins in the transfusional range reliable?

    Science.gov (United States)

    López, A; Gómez, L; Petinal, G; Adán, N; Alvarado, S; Carballo, N

    2018-02-27

    To evaluate the correlation and agreement in our unit and population of hemoglobin in gasometry versus hematology analyzer, to evaluate errors in transfusion or lack thereof. strong association between Point-of-care (POC) and hematimetry, with P<.001, with a coefficient of determination r 2 of 0.56, an intraclass correlation coefficient of 0.63 and a Lin's concordance correlation coefficient of 0.65. For hemoglobins less than 7g/dL, a success rate of 29.41% was obtained. Low-moderate agreement of POC hemoglobin with standard haemothymetry. High probability of errors in the indication of transfusion based on gasometer hemoglobins, especially in low hemoglobins. Copyright © 2018 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  4. A study on the structures of hemoglobin of diabetic patients by EXAFS technique

    International Nuclear Information System (INIS)

    Wang Yinsong; Tan Mingguang; Zhang Guilin

    2001-01-01

    Hemoglobin was the carrier of oxygen in blood circulation. For the patients with diabetes mellitus the enhancement of glycidate hemoglobin in blood causes the decrease of oxygen transmission function. The local atomic structures of iron in hemoglobin were determined by EXAFS techniques. The relationship between diabetes mellitus and hemoglobin structures was observed. The blood samples were taken from normal people, slight and serious diabetic patients. The results show that the coordination number of iron atoms and Fe-O bond length were almost the same for the three samples. However, for the samples of serious diabetic patients the Fe-N bond length increases by about 0.002 nm, the possible reasons were the increase of deoxyhemoglobin contents in their blood

  5. Lower versus Higher Hemoglobin Threshold for Transfusion in Septic Shock

    DEFF Research Database (Denmark)

    Holst, Lars B; Haase, Nicolai; Wetterslev, Jørn

    2014-01-01

    BACKGROUND: Blood transfusions are frequently given to patients with septic shock. However, the benefits and harms of different hemoglobin thresholds for transfusion have not been established. METHODS: In this multicenter, parallel-group trial, we randomly assigned patients in the intensive care...... unit (ICU) who had septic shock and a hemoglobin concentration of 9 g per deciliter or less to receive 1 unit of leukoreduced red cells when the hemoglobin level was 7 g per deciliter or less (lower threshold) or when the level was 9 g per deciliter or less (higher threshold) during the ICU stay...... were similar in the two intervention groups. CONCLUSIONS: Among patients with septic shock, mortality at 90 days and rates of ischemic events and use of life support were similar among those assigned to blood transfusion at a higher hemoglobin threshold and those assigned to blood transfusion...

  6. Effect of some high consumption spices on hemoglobin glycation.

    Science.gov (United States)

    Naderi, G H; Dinani, Narges J; Asgary, S; Taher, M; Nikkhoo, N; Boshtam, M

    2014-01-01

    Formation of glycation products is major factor responsible in complications of diabetes. Worldwide trend is toward the use of natural additives in reducing the complications of diseases. Therefore, there is a growing interest in natural antiglycation found in plants. Herbs and spices are one of the most important targets to search for natural antiglycation from the point of view of safety. This study investigated the ability of some of the spices to inhibit glycation process in a hemoglobin/glucose model system and compared their potency with each other. For this subject the best concentration and time to incubate glucose with hemoglobin was investigated. Then the glycosylation degree of hemoglobin in the presence of extracts by the three concentrations 0.25, 0.5 and 1 μg/ml was measured colorimetrically at 520 nm. Results represent that some of extracts such as wild caraway, turmeric, cardamom and black pepper have inhibitory effects on hemoglobin glycation. But some of the extracts such as anise and saffron have not only inhibitory effects but also aggravated this event and have proglycation properties. In accordance with the results obtained we can conclude that wild caraway, turmeric, cardamom and black pepper especially wild caraway extracts are potent antiglycation agents, which can be of great value in the preventive glycation-associated complications in diabetes.

  7. A novel hemoglobin variant found on the α1 chain: Hb KSVGH (HBA1: p.Lys57_Gly58insSerHisGlySerAlaGlnValLys).

    Science.gov (United States)

    Wang, Mei-Chun; Tsai, Kuo-Wang; Chu, Chih-Hsun; Yu, Ming-Sun; Lam, Hing-Chung

    2015-01-01

    Glycosylated hemoglobin (Hb A1C) is a crucial indicator for the long-term control and the diagnosis of diabetes. However, the presence of hemoglobin (Hb) variants may affect the measured value of Hb A1C and result in an abnormal graph trend and inconsistency between the clinical blood sugar test and Hb A1C values. In this study, laboratory data of 41,267 patients with diabetes were collected. The Hb A1C levels and the graph results were examined. We identified 74 cases containing abnormal Hb A1C graph trends. The conducted blood cell counts and capillary Hb electrophoresis were used to analyze Hb variants. We also determined gene variation for the Hb variants by a sequence approach. Fifteen different types of Hb variants were identified in this study. Among these, we found a novel variant in which the α1 subunit of Hb showed an insertion of 24 nucleotides (nts) between the 56th and 57th residues. We named this novel variant Hb Kaohsiung Veterans General Hospital (Hb KSVGH) (HBA1: p.Lys57_Gly58insSerHisGlySerAlaGlnValLys).

  8. TECHNIQUES OF EVALUATION OF HEMOGLOBIN OXYGEN SATURATION IN CLINICAL OPHTHALMOLOGY

    Directory of Open Access Journals (Sweden)

    S. Yu. Petrov

    2016-01-01

    Full Text Available Oxygen content in body fluids and tissues is an important indicator of life support functions. A number of ocular pathologies, e.g. glaucoma, are of presumable vascular origin which means altered blood supply and oxygen circulation. Most oxygen is transported in the blood in the association with hemoglobin. When passing through the capillaries, hemoglobin releases oxygen, converting from oxygenated form to deoxygenated form. This process is accompanied by the changes in spectral characteristics of hemoglobin which result in different colors of arterial and venous blood. Photometric technique for the measurement of oxygen saturation in blood is based on the differences in light absorption by different forms of hemoglobin. The measurement of saturation is called oximetry. Pulse oximetry with assessment of tissue oxygenation is the most commonly used method in medicine. The degree of hemoglobin oxygen saturation in the eye blood vessels is the most accessible for noninvasive studies during ophthalmoscopy and informative. Numerous studies showed the importance of this parameter for the diagnosis of retinopathy of various genesis, metabolic status analysis in hyperglycemia, diagnosis and control of treatment of glaucoma and other diseases involving alterations in eye blood supply. The specific method for evaluation of oxygen concentration is the measurement of pressure of oxygen dissolved in the blood, i.e. partial pressure of oxygen. In ophthalmological practice, this parameter is measured in anterior chamber fluid evaluating oxygen level for several ophthalmopathies including different forms of glaucoma, for instillations of hypotensive eye drops as well as in vitreous body near to the optic disc under various levels of intraocular pressure. Currently, monitoring of oxygen saturation in retinal blood vessels, i.e. retinal oximetry, is well developed. This technique is based on the assessment of light absorption by blood depending on

  9. Genetic hemoglobin disorders rather than iron deficiency are a major predictor of hemoglobin concentration in women of reproductive age in rural prey Veng, Cambodia.

    Science.gov (United States)

    Karakochuk, Crystal D; Whitfield, Kyly C; Barr, Susan I; Lamers, Yvonne; Devlin, Angela M; Vercauteren, Suzanne M; Kroeun, Hou; Talukder, Aminuzzaman; McLean, Judy; Green, Timothy J

    2015-01-01

    Anemia is common in Cambodian women. Potential causes include micronutrient deficiencies, genetic hemoglobin disorders, inflammation, and disease. We aimed to investigate factors associated with anemia (low hemoglobin concentration) in rural Cambodian women (18-45 y) and to investigate the relations between hemoglobin disorders and other iron biomarkers. Blood samples were obtained from 450 women. A complete blood count was conducted, and serum and plasma were analyzed for ferritin, soluble transferrin receptor (sTfR), folate, vitamin B-12, retinol binding protein (RBP), C-reactive protein (CRP), and α1 acid glycoprotein (AGP). Hemoglobin electrophoresis and multiplex polymerase chain reaction were used to determine the prevalence and type of genetic hemoglobin disorders. Overall, 54% of women had a genetic hemoglobin disorder, which included 25 different genotypes (most commonly, hemoglobin E variants and α(3.7)-thalassemia). Of the 420 nonpregnant women, 29.5% had anemia (hemoglobin 8.3 mg/L), hemoglobin disorders, respectively. There was no biochemical evidence of vitamin A deficiency (RBP 5 mg/L) and 26% (AGP >1 g/L) of nonpregnant women, respectively. By using an adjusted linear regression model, the strongest predictors of hemoglobin concentration were hemoglobin E homozygous disorder and pregnancy status. Other predictors were 2 other heterozygous traits (hemoglobin E and Constant Spring), parity, RBP, log ferritin, and vitamin B-12. Multiple biomarkers for anemia and iron deficiency were significantly influenced by the presence of hemoglobin disorders, hence reducing their diagnostic sensitivity. Further investigation of the unexpectedly low prevalence of IDA in Cambodian women is warranted. © 2015 American Society for Nutrition.

  10. Transverse water relaxation in whole blood and erythrocytes at 3T, 7T, 9.4T, 11.7T and 16.4T; determination of intracellular hemoglobin and extracellular albumin relaxivities.

    Science.gov (United States)

    Grgac, Ksenija; Li, Wenbo; Huang, Alan; Qin, Qin; van Zijl, Peter C M

    2017-05-01

    Blood is a physiological substance with multiple water compartments, which contain water-binding proteins such as hemoglobin in erythrocytes and albumin in plasma. Knowing the water transverse (R 2 ) relaxation rates from these different blood compartments is a prerequisite for quantifying the blood oxygenation level-dependent (BOLD) effect. Here, we report the Carr-Purcell-Meiboom-Gill (CPMG) based transverse (R 2CPMG ) relaxation rates of water in bovine blood samples circulated in a perfusion system at physiological temperature in order to mimic blood perfusion in humans. R 2CPMG values of blood plasma, lysed packed erythrocytes, lysed plasma/erythrocyte mixtures, and whole blood at 3 T, 7 T, 9.4 T, 11.7 T and 16.4 T were measured as a function of hematocrit or hemoglobin concentration, oxygenation, and CPMG inter-echo spacing (τ cp ). R 2CPMG in lysed cells showed a small τ cp dependence, attributed to the water exchange rate between free and hemoglobin-bound water to be much faster than τ cp . This was contrary to the tangential dependence in whole blood, where a much slower exchange between cells and blood plasma applies. Whole blood data were fitted as a function of τ cp using a general tangential correlation time model applicable for exchange as well as diffusion contributions to R 2CPMG , and the intercept R 20blood at infinitely short τ cp was determined. The R 20blood values at different hematocrit and the R 2CPMG values of lysed erythrocyte/plasma mixtures at different hemoglobin concentration were used to determine the relaxivity of hemoglobin inside the erythrocyte (r 2Hb ) and albumin (r 2Alb ) in plasma. The r 2Hb values obtained from lysed erythrocytes and whole blood were comparable at full oxygenation. However, while r 2Hb determined from lysed cells showed a linear dependence on oxygenation, this dependence became quadratic in whole blood. This possibly suggests an additional relaxation effect inside intact cells, perhaps due to hemoglobin

  11. Changes in hemoglobin-oxygen affinity with shape variations of red blood cells

    Science.gov (United States)

    Chowdhury, Aniket; Dasgupta, Raktim; Majumder, Shovan K.

    2017-10-01

    Shape variations of red blood cells (RBCs) are known to occur upon exposure to various drugs or under diseased conditions. The commonly observed discocytic RBCs can be transformed to echinocytic or stomatocytic shape under such conditions. Raman spectra of the three major shape variations, namely discocyte, echinocyte, and stomatocyte, of RBCs were studied while subjecting the cells to oxygenated and deoxygenated conditions. Analysis of the recorded spectra suggests an increased level of hemoglobin (Hb)-oxygen affinity for the echinocytes. Also, some level of Hb degradation could be noticed for the deoxygenated echinocytes. The effects may arise from a reduced level of intracellular adenosine triphosphate in echinocytic cells and an increased fraction of submembrane Hb.

  12. Reference interval determination of hemoglobin fractions in umbilical cord and placental blood by capillary electrophoresis.

    Science.gov (United States)

    Bó, Suzane Dal; de Oliveira Lemos, Fabiane Kreutz; Pedrazzani, Fabiane Spagnol; Cagliari, Cláudia Rosa; Scotti, Luciana

    2016-04-01

    Umbilical cord and placental blood (UCPB) is a rich source of hematopoietic stem cells widely used to treat diseases that did not have effective treatments until recently. Umbilical cord and placental blood banks (UCPBBs) are needed to be created to store UCPB. UCPB is collected immediately after birth, processed, and frozen until infusion. Detection of abnormal hemoglobins is one of UCPB screening tests available. The objective of the present study was to determine the reference interval for HbA, HbF, and HbA2 in UCPB using capillary electrophoresis. Methods: Observational retrospective study of UCPB samples undergoing hemoglobin electrophoresis was performed between April 2012 and May 2013. We analyzed 273 UCPB samples. All cords met the criteria of BrasilCORD. We found 19.9% (10.5–36.7%) for HbA, 80.1% (62.7–89.4%) for HbF, and 0.1% (0.0–0.6%) for HbA2. Data were expressed as median (P2.5–P97.5). Establishing specific reference intervals is the best option for most tests because such ranges reflect the status of the population in which the tests will be applied. The use of appropriate reference intervals ensures that clinical labs provide reliable information, thus enabling clinicians to correctly interpret results and choose the best approach for the target population.

  13. Haptoglobin blood test

    Science.gov (United States)

    The haptoglobin blood test measures the level of haptoglobin in your blood. Haptoglobin is a protein produced by the liver. It attaches to a certain type of hemoglobin in the blood. Hemoglobin is a blood cell that carries oxygen.

  14. 70-year old female patient with mismatch between hematocrit and hemoglobin values: the effects of cold agglutinin on complete blood count.

    Science.gov (United States)

    Ercan, Serif; Calışkan, Mustafa; Koptur, Erhan

    2014-01-01

    There are a number of pre-analytical and analytical factors, which cause false results in the complete blood count. The present case identifies cold agglutinins as the cause for the mismatch between hematocrit and hemoglobin values. 70-year old female patient had a history of cerebrovascular diseases and rheumatoid arthritis. During routine laboratory examination, the patient had normal leukocyte and platelet counts; however, the hemoglobin (Hb: 105 g/L) and hematocrit (HCT: 0.214 L/L) results were discordant. Hemolysis, lipemia and cold agglutinin were evaluated as possible reasons for the mismatch between hematocrit and hemoglobin values. First blood sample was slightly hemolysed. Redrawn sample without hemolysis or lipemia was analyzed but the mismatch became even more distinct (Hb: 104 g/L and HCT: 0.08 L/L). In this sample, the titration of the cold agglutinin was determined and found to be positive at 1:64 dilution ratios. After an incubation of the sample at 37°C for 2 hours, reversibility of agglutination was observed. We conclude that cold agglutinins may interfere with the analysis of erythrocyte and erythrocyte-related parameters (HCT, MCV, MCH and MCHC); however, Hb, leukocyte and platelet counts are not affected.

  15. Effect of hemolysis and free hemoglobin on optical hematocrit measurements in the extracorporeal circulation.

    Science.gov (United States)

    Paluszkiewicz, Aleksandra; Kellner, Josef; Elshehabi, Morad; Schneditz, Daniel

    2008-01-01

    Clinically significant hemolysis is a rare but serious problem in dialysis. Because hemolysis affects red blood cell count and optical density of plasma it has been speculated whether techniques used for online blood volume monitoring would be useful to detect hemolysis. In this study the influence of free hemoglobin on hematocrit and relative blood volume changes measured by optical means (CritLine, HemaMetrics, Kaysville, UT) were examined using an in vitro model with bovine blood. Free hemoglobin solutions were added in steps to circulating whole blood at baseline hematocrits covering a range from 30% to 60% and at blood flows of approximately 200 and 400 ml/min. The free hemoglobin concentration reached was in the range of 2 to 3 g/dl. The presence of free hemoglobin led to a relative increase in hematocrit in the range of 0.3% per 0.1 g of free hemoglobin per dl (+3% dl/g). As an increase in hematocrit is interpreted as a decrease in blood volume, this change referred to an apparent decrease in relative blood volume in the same order of magnitude (-3% dl/g). Effects were more pronounced at low baseline hematocrit. Thus, although optical hematocrit readings are affected by the presence of free hemoglobin the changes at levels associated with clinical symptoms appear to be too small to be accurately detected in the in vivo situation where the hematocrit and the resulting optical signal is affected by various physiological processes and therefore much noisier.

  16. Validated hemoglobin-depletion approach for red blood cell lysate proteome analysis by means of 2D PAGE and Orbitrap MS.

    Science.gov (United States)

    Walpurgis, Katja; Kohler, Maxie; Thomas, Andreas; Wenzel, Folker; Geyer, Hans; Schänzer, Wilhelm; Thevis, Mario

    2012-08-01

    The analysis of the cytosolic red blood cell (RBC) proteome is negatively affected by the high intracellular amount of hemoglobin complicating the detection of low-abundant cytosolic proteins. In this study, an alternative approach for the preparation of hemoglobin-depleted RBC lysates is presented, which was established in combination with downstream 2D PAGE analysis and Orbitrap MS. Hemoglobin removal was accomplished by using HemoVoid(TM) depletion reagent, which enabled a very efficient enrichment of low-abundant proteins by simultaneously reducing the hemoglobin concentration of the sample. After defining selected sample preparation protocol characteristics including specificity/selectivity, precision and linearity, a 2D reference map (pH 4-7) of the cytosolic RBC proteome was generated and a total of 189 different proteins were identified. Thus, the presented approach proved to be highly suitable to prepare reproducible high-resolution 2D protein maps of the RBC cytosol and provides a helpful tool for future studies investigating disease- or storage-induced changes of the cytosolic RBC proteome. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Optimization of a colorimetric assay for glycosylated human serum albumin

    International Nuclear Information System (INIS)

    Bohney, J.P.; Feldhoff, R.C.

    1986-01-01

    The thiobarbituric acid (TBA) assay has been used for several years to quantitate the amount of glucose which has been non-enzymatically linked to hemoglobin and other proteins. The ketoamine-protein adduct is converted to 5-hydroxymethylfurfural (HMF) by mild hydrolysis with oxalic acid. Reaction of HMF with TBA yields a colored product which has an absorbance maximum at 443 nm. Several modifications of the original procedure has been published, but none permit the unambiguous quantitation of glycosylated human serum albumin (glc-HSA). Problems relate to reagent preparation and stability, the time and temperature of hydrolysis, the choice of standards, and background color corrections. The authors have found that maximum color yield occurs after hydrolysis in an autoclave for 2 h. This increases the sensitivity 3-fold and cuts the assay time in half relative to hydrolysis for 4.5 h at 100 0 C. A NaBH 4 reduction of a parallel protein sample must be performed to correct for variable background color associated with different sample sources and amounts. HMF can be used as a standard, however, corrections must be made for HMF degradation. Fructose is a better standard, but HMF formation from fructose is faster than formation from glc-HSA. This may result in an underestimate of percent glycosylation. The best standard appears to be glc-HSA prepared with [ 3 H]glucose. It appears that with proper controls and standards the TBA assay can be used to determine actual rather than relative percent glycosylation

  18. 21 CFR 866.5470 - Hemoglobin immunological test system.

    Science.gov (United States)

    2010-04-01

    .... Measurements of free hemoglobin aid in the diagnosis of various hematologic disorders, such as sickle cell... blood cells), and leukemia (cancer of the blood-forming organs). (b) Classification. Class II...

  19. Stability and Application of Reactive Nitrogen and Oxygen Species-Induced Hemoglobin Modifications in Dry Blood Spots As Analyzed by Liquid Chromatography Tandem Mass Spectrometry.

    Science.gov (United States)

    Chen, Hauh-Jyun Candy; Fan, Chih-Huang; Yang, Ya-Fen

    2016-12-19

    Dried blood spot (DBS) is an emerging microsampling technique for the bioanalysis of small molecules, including fatty acids, metabolites, drugs, and toxicants. DBS offers many advantages as a sample format including easy sample collection and cheap sample shipment. Hemoglobin adducts have been recognized as a suitable biomarker for monitoring chemical exposure. We previously reported that certain modified peptides in hemoglobin derived from reactive chlorine, nitrogen, and oxygen species are associated with factors including smoking, diabetes mellitus, and aging. However, the stability of these oxidation-induced modifications of hemoglobin remains unknown and whether they can be formed artifactually during storage of DBS. To answer these questions, globin extracted from the DBS cards was analyzed, and the stability of the modifications was evaluated. After storage of the DBS cards at 4 °C or room temperature up to 7 weeks, we isolated globin from a quarter of the spot every week. The extents of 11 sites and types of post-translational modifications (PTMs), including nitration and nitrosylation of tyrosine and oxidation of cysteine and methionine residues, in human hemoglobin were measured in the trypsin digest by nanoflow liquid chromatography-nanospray ionization tandem mass spectrometry (nanoLC-NSI/MS/MS) using selected reaction monitoring. The extents of all these PTMs are stable within 14 days when stored on DBS at room temperature and at 4 °C, while those from direct extraction of fresh blood are stable for at least 8 weeks when stored as an aqueous solution at -20 °C. Extraction of globin from a DBS card is of particular importance for hemolytic blood samples. To our knowledge, this is the first report on the stability of oxidative modifications of hemoglobin on DBSs, which are stable for 14 days under ambient conditions (room temperature, in air). Therefore, it is feasible and convenient to analyze these hemoglobin modifications from DBSs in studies

  20. Comparison of three noninvasive methods for hemoglobin screening of blood donors.

    Science.gov (United States)

    Ardin, Sergey; Störmer, Melanie; Radojska, Stela; Oustianskaia, Larissa; Hahn, Moritz; Gathof, Birgit S

    2015-02-01

    To prevent phlebotomy of anemic individuals and to ensure hemoglobin (Hb) content of the blood units, Hb screening of blood donors before donation is essential. Hb values are mostly evaluated by measurement of capillary blood obtained from fingerstick. Rapid noninvasive methods have recently become available and may be preferred by donors and staff. The aim of this study was to evaluate for the first time all different noninvasive methods for Hb screening. Blood donors were screened for Hb levels in three different trials using three different noninvasive methods (Haemospect [MBR Optical Systems GmbH & Co. KG], NBM 200 [LMB Technology GmbH], Pronto-7 [Masimo Europe Ltd]) in comparison to the established fingerstick method (CompoLab Hb [Fresenius Kabi GmbH]) and to levels obtained from venous samples on a cell counter (Sysmex [Sysmex Europe GmbH]) as reference. The usability of the noninvasive methods was assessed with an especially developed survey. Technical failures occurred by using the Pronto-7 due to nail polish, skin color, or ambient light. The NBM 200 also showed a high sensitivity to ambient light and noticeably lower Hb levels for women than obtained from the Sysmex. The statistical analysis showed the following bias and standard deviation of differences of all methods in comparison to the venous results: Haemospect, -0.22 ± 1.24; NBM, 200 -0.12 ± 1.14; Pronto-7, -0.50 ± 0.99; and CompoLab Hb, -0.53 ± 0.81. Noninvasive Hb tests represent an attractive alternative by eliminating pain and reducing risks of blood contamination. The main problem for generating reliable results seems to be preanalytical variability in sampling. Despite the sensitivity to environmental stress, all methods are suitable for Hb measurement. © 2014 AABB.

  1. Evaluation of non cyanide methods for hemoglobin estimation

    Directory of Open Access Journals (Sweden)

    Vinaya B Shah

    2011-01-01

    Full Text Available Background: The hemoglobincyanide method (HiCN method for measuring hemoglobin is used extensively worldwide; its advantages are the ready availability of a stable and internationally accepted reference standard calibrator. However, its use may create a problem, as the waste disposal of large volumes of reagent containing cyanide constitutes a potential toxic hazard. Aims and Objective: As an alternative to drabkin`s method of Hb estimation, we attempted to estimate hemoglobin by other non-cyanide methods: alkaline hematin detergent (AHD-575 using Triton X-100 as lyser and alkaline- borax method using quarternary ammonium detergents as lyser. Materials and Methods: The hemoglobin (Hb results on 200 samples of varying Hb concentrations obtained by these two cyanide free methods were compared with a cyanmethemoglobin method on a colorimeter which is light emitting diode (LED based. Hemoglobin was also estimated in one hundred blood donors and 25 blood samples of infants and compared by these methods. Statistical analysis used was Pearson`s correlation coefficient. Results: The response of the non cyanide method is linear for serially diluted blood samples over the Hb concentration range from 3gm/dl -20 gm/dl. The non cyanide methods has a precision of + 0.25g/dl (coefficient of variation= (2.34% and is suitable for use with fixed wavelength or with colorimeters at wavelength- 530 nm and 580 nm. Correlation of these two methods was excellent (r=0.98. The evaluation has shown it to be as reliable and reproducible as HiCN for measuring hemoglobin at all concentrations. The reagents used in non cyanide methods are non-biohazardous and did not affect the reliability of data determination and also the cost was less than HiCN method. Conclusions: Thus, non cyanide methods of Hb estimation offer possibility of safe and quality Hb estimation and should prove useful for routine laboratory use. Non cyanide methods is easily incorporated in hemobloginometers

  2. Purification, characterization and sequence analyses of the extracellular giant hemoglobin from Oligobrachia mashikoi

    OpenAIRE

    Nakagawa, Taro; Onoda, Seiko; Kanemori, Masaaki; Sasayama, Yuichi; Fukumori, Yoshihiro

    2005-01-01

    We purified an extracellular hemoglobin with the molecular mass of ca. 440 kDa from the whole homogenates of Oligobrachia mashikoi (phylum Pogonophora) by a one-step gel-filtration. The preparation was pure to be crystallized. The P50 values of the hemoglobin and the fresh blood prepared from O. mashikoi were about 0.82 Torr and 0.9 Torr, respectively, which were much lower than the P50 value of human hemoglobin. However, the n values of the hemoglobin and the blood were about 1.2 and 1.1, re...

  3. Biophysical Monitoring and dose response characteristics of irradiated hemoglobin

    International Nuclear Information System (INIS)

    Elshemey, W.M; Selim, N.S.; Desouky, O.

    2003-01-01

    The present work aims to move a step forward towards a deeper understanding of the scattering of x-ray, from lyophilized biological samples. Comparative study has been performed using LAXS and UV-visible spectrophotometry for monitoring the dose response characteristics of the hemoglobin molecule of irradiated blood. Blood samples were irradiated at doses ranging from 5 up to 100 Gy. Diluted hemoglobin solution was scanned in the UV- visible range (200-700 nm), and lyophilized hemoglobin was prepared for LAXS measurement. The radiation-induced changes in the hemoglobin structure have been evaluated. The LAXS profile of hemoglobin molecule is characterized by the presence of two peaks in the forward direction of scattering. These peaks were found to be sensitive to the variations in the molecular structure of a given sample. The obtained results suggest that the 1 s t peak, recorded at 4.65 o , is sensitive to the tertiary and quaternary structure of the globin part, while the major peak, recorded at 10.5 o , appeared to be related to its primary and secondary structure

  4. Hemoglobin as a factor in the control of tumor oxygenation

    International Nuclear Information System (INIS)

    Hirst, D.G.

    1987-01-01

    The concentration of hemoglobin in the blood has been shown to have a market effect on the radiosensitivity of human and animal tumors. Experimental studies in mice indicate that radiosensitivity is influenced by a change in the hemoglobin level rather than by the absolute concentration. This dependence may be exploited to therapeutic advantage. Recent studies of hemoglobin/oxygen affinity have shown that the concentration of 2,3 diphosphoglycerate (2,3 DPG) affects tumor sensitivity to X-rays. Increased 2,3 DPG levels increase radiosensitivity in several mouse tumors. The time dependence of this effect remains to be established. The effective application of these effects in man may depend on the development of drugs which produce changes in hemoglobin affinity without the need for blood transfusions. Several drugs are currently being investigated

  5. Clinical, hematological and genetic data of a cohort of children with hemoglobin SD

    Directory of Open Access Journals (Sweden)

    Paulo do Val Rezende

    Full Text Available ABSTRACT INTRODUCTION: The hemoglobin FSD is very uncommon in newborn screening programs for sickle cell disease. In the program of Minas Gerais, Brazil, the clinical course of children with hemoglobin SD was observed to be heterogeneous. The objective of this study was to estimate the incidence (1999-2012 and to describe the natural history of a cohort of newborns with hemoglobin SD. METHODS: Isoelectric focusing was the primary method used in newborn screening. Polymerase chain reaction-restriction fragment length polymorphism and gene sequencing were used to identify mutant alleles and for haplotyping. Gap-polymerase chain reaction was used to detect alpha-thalassemia. RESULTS: Eleven cases of hemoglobin S/D-Punjab and eight of Hb S-Korle Bu were detected. Other variants with hemoglobin D mobility were not identified. All hemoglobin D-Punjab and hemoglobin Korle Bu alleles were associated with haplotype I. Among the children with hemoglobin S/D-Punjab, there were four with the ßS CAR haplotype, six with the Benin haplotype, and one atypical. Results of laboratory tests for hemoglobin S/D-Punjab and hemoglobin S-Korle Bu were: hemoglobin 8.0 and 12.3 g/dL (p-value <0.001, leukocyte count 13.9 × 109/L and 10.5 × 109/L (p-value = 0.003, reticulocytes 7.5% and 1.0% (p-value <0.001, hemoglobin F concentration 16.1% and 6.9% (p-value = 0.001 and oxygen saturation 91.9% and 97% (p-value = 0.002, respectively. Only hemoglobin S/D-Punjab children had acute pain crises and needed blood transfusions or hydroxyurea. Those with the Benin ßS haplotype had higher total hemoglobin and hemoglobin F concentrations compared to the CAR haplotype. Transcranial Doppler was normal in all children. CONCLUSION: The clinical course and blood cell counts of children with hemoglobin S/D-Punjab were very similar to those of hemoglobin SS children. In contrast, children with hemoglobin S-Korle Bu had clinical course and blood cell counts like children with the sickle

  6. MR Imaging-derived Oxygen-Hemoglobin Dissociation Curves and Fetal-Placental Oxygen-Hemoglobin Affinities.

    Science.gov (United States)

    Avni, Reut; Golani, Ofra; Akselrod-Ballin, Ayelet; Cohen, Yonni; Biton, Inbal; Garbow, Joel R; Neeman, Michal

    2016-07-01

    Purpose To generate magnetic resonance (MR) imaging-derived, oxygen-hemoglobin dissociation curves and to map fetal-placental oxygen-hemoglobin affinity in pregnant mice noninvasively by combining blood oxygen level-dependent (BOLD) T2* and oxygen-weighted T1 contrast mechanisms under different respiration challenges. Materials and Methods All procedures were approved by the Weizmann Institutional Animal Care and Use Committee. Pregnant mice were analyzed with MR imaging at 9.4 T on embryonic days 14.5 (eight dams and 58 fetuses; imprinting control region ICR strain) and 17.5 (21 dams and 158 fetuses) under respiration challenges ranging from hyperoxia to hypoxia (10 levels of oxygenation, 100%-10%; total imaging time, 100 minutes). A shorter protocol with normoxia to hyperoxia was also performed (five levels of oxygenation, 20%-100%; total imaging time, 60 minutes). Fast spin-echo anatomic images were obtained, followed by sequential acquisition of three-dimensional gradient-echo T2*- and T1-weighted images. Automated registration was applied to align regions of interest of the entire placenta, fetal liver, and maternal liver. Results were compared by using a two-tailed unpaired Student t test. R1 and R2* values were derived for each tissue. MR imaging-based oxygen-hemoglobin dissociation curves were constructed by nonlinear least square fitting of 1 minus the change in R2*divided by R2*at baseline as a function of R1 to a sigmoid-shaped curve. The apparent P50 (oxygen tension at which hemoglobin is 50% saturated) value was derived from the curves, calculated as the R1 scaled value (x) at which the change in R2* divided by R2*at baseline scaled (y) equals 0.5. Results The apparent P50 values were significantly lower in fetal liver than in maternal liver for both gestation stages (day 14.5: 21% ± 5 [P = .04] and day 17.5: 41% ± 7 [P hemoglobin dissociation curves with a shorter protocol that excluded the hypoxic periods was demonstrated. Conclusion MR imaging

  7. Hemoglobin concentration determination based on near infrared spatially resolved transmission spectra

    Science.gov (United States)

    Zhang, Linna; Li, Gang; Lin, Ling

    2016-10-01

    Spatially resolved diffuse reflectance spectroscopy method has been proved to be more effective than single point spectroscopy method in the experiment to predict the concentration of the Intralipid diluted solutions. However, Intralipid diluted solution is simple, cannot be the representative of turbid liquids. Blood is a natural and meaningful turbid liquid, more complicate. Hemoglobin is the major constituent of the whole blood. And hemoglobin concentration is commonly used in clinical medicine to diagnose many diseases. In this paper, near infrared spatially resolved transmission spectra (NIRSRTS) and Partial Least Square Regression (PLSR) were used to predict the hemoglobin concentration of human blood. The results showed the prediction ability for hemoglobin concentration of the proposed method is better than single point transmission spectroscopy method. This paper demonstrated the feasibility of the spatially resolved diffuse reflectance spectroscopy method for practical liquid composition analysis. This research provided a new thinking of practical turbid liquid composition analysis.

  8. Importance of hemoglobin concentration to exercise: acute manipulations

    DEFF Research Database (Denmark)

    Calbet, José A L; Lundby, Carsten; Koskolou, Maria

    2006-01-01

    An acute reduction of blood hemoglobin concentration ([Hb]), even when the circulating blood volume is maintained, results in lower (.)V(O(2)(max) and endurance performance, due to the reduction of the oxygen carrying capacity of blood. Conversely, an increase of [Hb] is associated with enhanced...

  9. A comparison of blood nitric oxide metabolites and hemoglobin functional properties among diving mammals.

    Science.gov (United States)

    Fago, Angela; Parraga, Daniel Garcia; Petersen, Elin E; Kristensen, Niels; Giouri, Lea; Jensen, Frank B

    2017-03-01

    The ability of marine mammals to hunt prey at depth is known to rely on enhanced oxygen stores and on selective distribution of blood flow, but the molecular mechanisms regulating blood flow and oxygen transport remain unresolved. To investigate the molecular mechanisms that may be important in regulating blood flow, we measured concentration of nitrite and S-nitrosothiols (SNO), two metabolites of the vasodilator nitric oxide (NO), in the blood of 5 species of marine mammals differing in their dive duration: bottlenose dolphin, South American sea lion, harbor seal, walrus and beluga whale. We also examined oxygen affinity, sensitivity to 2,3-diphosphoglycerate (DPG) and nitrite reductase activity of the hemoglobin (Hb) to search for possible adaptive variations in these functional properties. We found levels of plasma and red blood cells nitrite similar to those reported for terrestrial mammals, but unusually high concentrations of red blood cell SNO in bottlenose dolphin, walrus and beluga whale, suggesting enhanced SNO-dependent signaling in these species. Purified Hbs showed similar functional properties in terms of oxygen affinity and sensitivity to DPG, indicating that reported large variations in blood oxygen affinity among diving mammals likely derive from phenotypic variations in red blood cell DPG levels. The nitrite reductase activities of the Hbs were overall slightly higher than that of human Hb, with the Hb of beluga whale, capable of longest dives, having the highest activity. Taken together, these results underscore adaptive variations in circulatory NO metabolism in diving mammals but not in the oxygenation properties of the Hb. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Decreased serum glucose and glycosylated hemoglobin levels in patients with Chuvash polycythemia: a role for HIF in glucose metabolism

    Science.gov (United States)

    McClain, Donald A.; Abuelgasim, Khadega A.; Nouraie, Mehdi; Salomon-Andonie, Juan; Niu, Xiaomei; Miasnikova, Galina; Polyakova, Lydia A.; Sergueeva, Adelina; Okhotin, Daniel J.; Cherqaoui, Rabia; Okhotin, David; Cox, James E.; Swierczek, Sabina; Song, Jihyun; Simon, M.Celeste; Huang, Jingyu; Simcox, Judith A.; Yoon, Donghoon; Prchal, Josef T.; Gordeuk, Victor R.

    2012-01-01

    In Chuvash polycythemia, a homozygous 598C>T mutation in the von Hippel-Lindau gene (VHL) leads to an R200W substitution in VHL protein, impaired degradation of α-subunits of hypoxia inducible factor (HIF)-1 and HIF-2, and augmented hypoxic responses during normoxia. Chronic hypoxia of high altitude is associated with decreased serum glucose and insulin concentrations. Other investigators reported that HIF-1 promotes cellular glucose uptake by increased expression of GLUT1 and increased glycolysis by increased expression of enzymes such as PDK. On the other hand, inactivation of Vhl in murine liver leads to hypoglycemia associated with a HIF-2-related decrease in the expression of the gluconeogenic enzymes genes Pepck, G6pc, and Glut2. We therefore hypothesized that glucose concentrations are decreased in individuals with Chuvash polycythemia. We found that 88 Chuvash VHLR200W homozygotes had lower random glucose and glycosylated hemoglobin A1c levels than 52 Chuvash subjects with wildtype VHL alleles. Serum metabolomics revealed higher glycerol and citrate levels in the VHLR200W homozygotes. We expanded these observations in VHLR200W homozygote mice and found that they had lower fasting glucose values and lower glucose excursions than wild-type control mice but no change in fasting insulin concentrations. Hepatic expression of Glut2 and G6pc but not Pdk2 was decreased and skeletal muscle expression of Glut1, Pdk1 and Pdk4 was increased. These results suggest that both decreased hepatic gluconeogenesis and increased skeletal uptake and glycolysis contribute to the decreased glucose concentrations. Further study is needed to determine whether pharmacologically manipulating HIF expression might be beneficial for treatment of diabetic patients. PMID:23015148

  11. Rheological Variations among Nigerians with Different Hemoglobin ...

    African Journals Online (AJOL)

    Some Hemorheological determinants such as whole blood viscosity (WBV) and plasma viscosity (PV) and Plasma Fibrinogen Concentration (PFC) were measured with standard methods. We recorded a relatively unchanged whole blood viscosities in subjects with various hemoglobin genotypes (AA, AS and SS; P>0.05, ...

  12. INFLUENCE OF HERBAL EXTRACTS ON METABOLIC DISTURBANCES IN DIABETES MELLITUS AND INSULIN RESISTANCE MODEL

    Directory of Open Access Journals (Sweden)

    T. V. Yakimova

    2015-01-01

    Full Text Available The aim of this research was to assess the influence on metabolic processes of herbal extracts, used in diets with different fat content, in diabetes mellitus and insulin resistance model.Material and methods. The experiments were performing on 90 noninbred male albino rats. Diabetes mellitus was modeling with twice-repeated intraperitoneal streptozotocine (30 mg/kg injections. For the insulin resistance formation animals were fad meal with 30% fat content. Against the background rats were administering into the stomach nettle leafs (Urtica dioica L., 100 mg/kg, burdock roots (Arctium lappa L., 25 mg/kg extracts or intraperitoneal insulin preparation Actrapide HM Penfill (3 mg/kg daily during 10 days. During period of agents introduction one-half of animals continued to receive food with high fat content, the other half received diet with 8% fat content. The third rats group received only food with low fat content without extracts or insulin administration. In blood was measured the glucose, glycosylated hemoglobin, creatinine, urea, uric acid content, in liver homogenates – glycogen, protein content, aminotransferases and glucose-6phosphatase activity, in muscle homogenates – glycogen and protein content.Results. After streptozotocine injections and diet with 30% fat content the blood glucose level became by 4.0–5.3 fold more than level of intact animals, increased the hemoglobin glycosylation, also creatinine, urea, uric acid blood content, in liver and muscle homogenates raised glycogen content, decreased protein quantity, in liver homogenates increased aminotranferases and glucose-6-phosphatase activity. In animals only feeding with 8% fat diminished hyperglycemia, creatinine blood retention, the liver glycogen content and recovered its protein resources. The nettle or burdock extracts administrating to animals that continued to receive high fat meal decreased the blood glucose, glycosylated hemoglobin and creatinine content, the liver

  13. Optimization of a colorimetric assay for glycosylated human serum albumin

    Energy Technology Data Exchange (ETDEWEB)

    Bohney, J.P.; Feldhoff, R.C.

    1986-05-01

    The thiobarbituric acid (TBA) assay has been used for several years to quantitate the amount of glucose which has been non-enzymatically linked to hemoglobin and other proteins. The ketoamine-protein adduct is converted to 5-hydroxymethylfurfural (HMF) by mild hydrolysis with oxalic acid. Reaction of HMF with TBA yields a colored product which has an absorbance maximum at 443 nm. Several modifications of the original procedure has been published, but none permit the unambiguous quantitation of glycosylated human serum albumin (glc-HSA). Problems relate to reagent preparation and stability, the time and temperature of hydrolysis, the choice of standards, and background color corrections. The authors have found that maximum color yield occurs after hydrolysis in an autoclave for 2 h. This increases the sensitivity 3-fold and cuts the assay time in half relative to hydrolysis for 4.5 h at 100/sup 0/C. A NaBH/sub 4/ reduction of a parallel protein sample must be performed to correct for variable background color associated with different sample sources and amounts. HMF can be used as a standard, however, corrections must be made for HMF degradation. Fructose is a better standard, but HMF formation from fructose is faster than formation from glc-HSA. This may result in an underestimate of percent glycosylation. The best standard appears to be glc-HSA prepared with (/sup 3/H)glucose. It appears that with proper controls and standards the TBA assay can be used to determine actual rather than relative percent glycosylation.

  14. Aspartic protease activities of schistosomes cleave mammalian hemoglobins in a host-specific manner

    Directory of Open Access Journals (Sweden)

    Jeffrey W Koehler

    2007-02-01

    Full Text Available We examined the efficiency of digestion of hemoglobin from four mammalian species, human, cow, sheep, and horse by acidic extracts of mixed sex adults of Schistosoma japonicum and S. mansoni. Activity ascribable to aspartic protease(s from S. japonicum and S. mansoni cleaved human hemoglobin. In addition, aspartic protease activities from S. japonicum cleaved hemoglobin from bovine, sheep, and horse blood more efficiently than did the activity from extracts of S. mansoni. These findings support the hypothesis that substrate specificity of hemoglobin-degrading proteases employed by blood feeding helminth parasites influences parasite host species range; differences in amino acid sequences in key sites of the parasite proteases interact less or more efficiently with the hemoglobins of permissive or non-permissive hosts.

  15. The Effects of Dietary Iron and Capsaicin on Hemoglobin, Blood Glucose, Insulin Tolerance, Cholesterol, and Triglycerides, in Healthy and Diabetic Wistar Rats.

    Science.gov (United States)

    Márquez-Ibarra, Adriana; Huerta, Miguel; Villalpando-Hernández, Salvador; Ríos-Silva, Mónica; Díaz-Reval, María I; Cruzblanca, Humberto; Mancilla, Evelyn; Trujillo, Xóchitl

    2016-01-01

    Our aim was to assess the effects of dietary iron, and the compound capsaicin, on hemoglobin as well as metabolic indicators including blood glucose, cholesterol, triglycerides, insulin, and glucose tolerance. Our animal model was the Wistar rat, fed a chow diet, with or without experimentally induced diabetes. Diabetic males were fed control, low, or high-iron diets, the latter, with or without capsaicin. Healthy rats were fed identical diets, but without the capsaicin supplement. We then measured the parameters listed above, using the Student t-test and ANOVA, to compare groups. Healthy rats fed a low-iron diet exhibited significantly reduced total cholesterol and triglyceride levels, compared with rats fed a control diet. Significantly reduced blood lipid was also provoked by low dietary iron in diabetic rats, compared with those fed a control diet. Insulin, and glucose tolerance was only improved in healthy rats fed the low-iron diet. Significant increases in total cholesterol were found in diabetic rats fed a high-iron diet, compared with healthy rats fed the same diet, although no statistical differences were found for triglycerides. Hemoglobin levels, which were not statistically different in diabetic versus healthy rats fed the high-iron diet, fell when capsaicin was added. Capsaicin also provoked a fall in the level of cholesterol and triglycerides in diabetic animals, versus diabetics fed with the high iron diet alone. In conclusion, low levels of dietary iron reduced levels of serum triglycerides, hemoglobin, and cholesterol, and significantly improved insulin, and glucose tolerance in healthy rats. In contrast, a high-iron diet increased cholesterol significantly, with no significant changes to triglyceride concentrations. The addition of capsaicin to the high-iron diet (for diabetic rats) further reduced levels of hemoglobin, cholesterol, and triglycerides. These results suggest that capsaicin, may be suitable for the treatment of elevated hemoglobin

  16. A comparative study of fasting, postprandial blood glucose and glycated hemoglobin for diagnosing diabetes mellitus in staff members of MMIMSR, Mullana, Ambala

    Directory of Open Access Journals (Sweden)

    Qazi Najeeb

    2015-01-01

    Full Text Available Introduction: For decades, the diagnosis of diabetes mellitus was based on blood glucose criteria, either the fasting blood glucose (FBG or a 2-h value in the 75-g oral glucose tolerance test. In 2009, an International Expert Committee that included representatives of the American Diabetes Association (ADA, International Diabetes Federation and European Association for the Study of Diabetes recommended the use of the HbA1c test to diagnose diabetes with a threshold of ≥6.5% and this criterion was finally adopted by ADA in 2010. Hence, the study was undertaken to evaluate the predictive efficacy of glycated hemoglobin as a diagnostic tool for diabetes mellitus and to identify individuals at risk of developing diabetes mellitus using Indian Diabetes Risk Score (IDRS. Materials and Methods: This cross-sectional study was conducted on the staff members of the Maharishi Markandeshwar Institute of Medical Science and Research, Mullana, Ambala, Haryana, India. Out of the total 800 staff members, 200 staff members were included in the study (88 faculty members, 37 staff nurses, 12 laboratory technicians, 25 clerical staff, 38 class IV selected by systemic random sampling. Every fifth member on the list was included in the sample. After obtaining the data, it was coded and analyzed using multivariate logistic regression analysis. Receiver operating characteristics curve analysis was used to predict the sensitivity, specificity, positivity, negativity and overall accuracy of a diagnostic test. A two-tailed test P < 0.05 was considered as statistically significant. Data was analyzed using SPSS 20 (IBM, Chicago, USA. Results: Out of 200 subjects, 19.5% were labeled diabetic using FBG, 23% by postprandial blood glucose (PPBG and 38.5% by using glycated hemoglobin according to ADA guidelines. A total of 62% had high-risk score out of which majority belonged to group-I (faculty followed by group-II (nursing staff and group-IV (clerical staff. With the

  17. Quantification of the N-glycosylated secretome by super-SILAC during breast cancer progression and in human blood Samples

    DEFF Research Database (Denmark)

    Boersema, P.J.; Geiger, T.; Wiśniewski, J.R.

    2013-01-01

    Cells secrete a large number of proteins to communicate with their surroundings. Furthermore, plasma membrane proteins and intracellular proteins can be released into the extracellular space by regulated or non-regulated processes. Here, we profiled the supernatant of 11 cell lines....... In total, 1398 unique N-glycosylation sites were identified and quantified. Enriching for N-glycosylated peptides focused the analysis on classically secreted and membrane proteins. N-glycosylated secretome profiles correctly clustered the different cell lines to their respective cancer stage, suggesting...

  18. Study of obesity associated proopiomelanocortin gene polymorphism

    African Journals Online (AJOL)

    Farida El-Baz Mohamed

    2016-03-10

    Mar 10, 2016 ... Blood Pressure Education Program [13]. (2). Auxological ..... factorial management plans involving nutrition, environ- mental control .... Association of glycosylated hemoglobin (HbA1c) levels with · insulin resistance in obese ...

  19. Analysis of hemoglobin adducts from acrylamide, glycidamide, and ethylene oxide in paired mother/cord blood samples from Denmark

    DEFF Research Database (Denmark)

    von Stedingk, Hans; Vikström, Anna C; Rydberg, Per

    2011-01-01

    The knowledge about fetal exposure to acrylamide/glycidamide from the maternal exposure through food is limited. Acrylamide, glycidamide, and ethylene oxide are electrophiles and form adducts with hemoglobin (Hb), which could be used for in vivo dose measurement. In this study, a method.......20-0.73) for glycidamide, and 0.43 (range 0.17-1.34) for ethylene oxide. In vitro studies with acrylamide and glycidamide showed a lower (0.38-0.48) rate of adduct formation with Hb in cord blood than with Hb in maternal blood, which is compatible with the structural differences in fetal and adult Hb. Together...... for analysis of Hb adducts by liquid chromatography-mass spectrometry, the adduct FIRE procedure, was applied to measurements of adducts from these compounds in maternal blood samples (n = 87) and umbilical cord blood samples (n = 219). The adduct levels from the three compounds, acrylamide, glycidamide...

  20. Action of radiation on biosynthesis of hemoglobin and some of its electrophoretic fractions

    International Nuclear Information System (INIS)

    Starodub, N.F.; Kriklivyj, I.A.; Shur'yan, I.M.

    1976-01-01

    Biosynthesis of hemoglobin and some of its electrophoretic fractions in red cells of peripheral blood and spleen of irradiated (650 R) rats has been studied. Hemoglobin synthesis is found to be most drastically inhibited in the first and second fractions on the first and eighth days after irradiation and in the fifth and sixth fractions on the eighth day (less expressed). The synthesis is restored on the twelfth day, the process under study proceeding more slowly in the above-mentioned fractions than in others. In the course of radiation sickness, the biosynthesis of certain hemoglobin fractions varies differently in the hemoglobin-synthesizing cells of peripheral blood than in the cells of spleenic erythroid series

  1. HEMOGLOBIN A1C, BLOOD PRESSURE, AND LDL-CHOLESTEROL CONTROL AMONG HISPANIC/LATINO ADULTS WITH DIABETES: RESULTS FROM THE HISPANIC COMMUNITY HEALTH STUDY/STUDY OF LATINOS (HCHS/SOL).

    Science.gov (United States)

    Casagrande, Sarah Stark; Aviles-Santa, Larissa; Corsino, Leonor; Daviglus, Martha L; Gallo, Linda C; Espinoza Giacinto, Rebeca A; Llabre, Maria M; Reina, Samantha A; Savage, Peter J; Schneiderman, Neil; Talavera, Gregory A; Cowie, Catherine C

    2017-10-01

    To determine the prevalence of Hispanic/Latino adults with diabetes who meet target hemoglobin A1c, blood pressure (BP), and low-density-lipoprotein cholesterol (LDL-C) recommendations, and angiotensin-converting enzyme (ACE) inhibitors/angiotensin receptor blocker (ARB) and statin medication use by heritage and sociodemographic and diabetes-related characteristics. Data were cross-sectional, collected between 2008 and 2011, and included adults age 18 to 74 years who reported a physician diagnosis of diabetes in the Hispanic Community Health Study/Study of Latinos (N = 2,148). Chi-square tests compared the prevalence of hemoglobin A1c, BP, and LDL-C targets and ACE/ARB and statin use across participant characteristics. Predictive margins regression was used to determine the prevalence adjusted for sociodemographic characteristics. The overall prevalence of A1c Latinos with diabetes living in the U.S. With 8.4% meeting all three recommendations, substantial opportunity exists to improve diabetes control in this population. A1c = hemoglobin A1c; ABC = hemoglobin A1c, blood pressure, low-density-lipoprotein cholesterol; ACE = angiotensin-converting enzyme; ADA = American Diabetes Association; ARB = angiotensin receptor blocker; BMI = body mass index; BP = blood pressure; CHD = coronary heart disease; CVD = cardiovascular disease; HCHS/SOL = Hispanic Community Health Study/Study of Latinos; LDL-C = low-density-lipoprotein cholesterol; NHANES = National Health and Nutrition Examination Survey; PAD = peripheral artery disease.

  2. Two-photon excited fluorescence emission from hemoglobin

    Science.gov (United States)

    Sun, Qiqi; Zeng, Yan; Zhang, Wei; Zheng, Wei; Luo, Yi; Qu, Jianan Y.

    2015-03-01

    Hemoglobin, one of the most important proteins in blood, is responsible for oxygen transportation in almost all vertebrates. Recently, we discovered two-photon excited hemoglobin fluorescence and achieved label-free microvascular imaging based on the hemoglobin fluorescence. However, the mechanism of its fluorescence emission still remains unknown. In this work, we studied the two-photon excited fluorescence properties of the hemoglobin subunits, heme/hemin (iron (II)/(III) protoporphyrin IX) and globin. We first studied the properties of heme and the similar spectral and temporal characteristics of heme and hemoglobin fluorescence provide strong evidence that heme is the fluorophore in hemoglobin. Then we studied the fluorescence properties of hemin, globin and methemoglobin, and found that the hemin may have the main effect on the methemoglobin fluorescence and that globin has tryptophan fluorescence like other proteins. Finally, since heme is a centrosymmetric molecule, that the Soret band fluorescence of heme and hemoglobin was not observed in the single photon process in the previous study may be due to the parity selection rule. The discovery of heme two-photon excited fluorescence may open a new window for heme biology research, since heme as a cofactor of hemoprotein has many functions, including chemical catalysis, electron transfer and diatomic gases transportation.

  3. High impact of uranyl ions on carrying-releasing oxygen capability of hemoglobin-based blood substitutes

    Energy Technology Data Exchange (ETDEWEB)

    Duan, Li; Du, Lili; Liu, Wenyuan; Liu, Zhichao [Northwest Institute of Nuclear Technology, Xi' an, Shaanxi (China); Jia, Yi; Li, Junbai [Beijing National Laboratory for Molecular Sciences, CAS Key Laboratory of Colloid Interface and Chemical Thermodynamics, Institute of Chemistry, Chinese Academy of Sciences, Beijing (China)

    2015-01-07

    The effect of radioactive UO{sub 2}{sup 2+} on the oxygen-transporting capability of hemoglobin-based oxygen carriers has been investigated in vitro. The hemoglobin (Hb) microspheres fabricated by the porous template covalent layer-by-layer (LbL) assembly were utilized as artificial oxygen carriers and blood substitutes. Magnetic nanoparticles of iron oxide (Fe{sub 3}O{sub 4}) were loaded in porous CaCO{sub 3} particles for magnetically assisted chemical separation (MACS). Through the adsorption spectrum of magnetic Hb microspheres after adsorbing UO{sub 2}{sup 2+}, it was found that UO{sub 2}{sup 2+} was highly loaded in the magnetic Hb microspheres, and it shows that the presence of UO{sub 2}{sup 2+} in vivo destroys the structure and oxygen-transporting capability of Hb microspheres. In view of the high adsorption capacity of UO{sub 2}{sup 2+}, the as-assembled magnetic Hb microspheres can be considered as a novel, highly effective adsorbent for removing metal toxins from radiation-contaminated bodies, or from nuclear-power reactor effluent before discharge into the environment. (copyright 2015 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  4. Regional variations in frequency of glycosylated hemoglobin (HbA1c) monitoring in Korea: A multilevel analysis of nationwide data.

    Science.gov (United States)

    Yoo, Kyoung-Hun; Shin, Dong-Wook; Cho, Mi-Hee; Kim, Sang-Hyuck; Bahk, Hyun-Jung; Kim, Shin-Hye; Jeong, Su-Min; Yun, Jae-Moon; Park, Jin-Ho; Kim, Heesun; Cho, BeLong

    2017-09-01

    Suboptimal frequency of glycosylated hemoglobin (HbA1c) monitoring is associated with poor diabetes control. We aimed to analyze compliance to HbA1c testing guidelines and explore associated individual and area-level determinants, focusing on regional variation. This cross-sectional study between the period of 2012-2013 was conducted by using the Korean National Health Insurance Research Database, and included 45,634 patients diagnosed with diabetes mellitus, who were prescribed any anti-diabetic medications, including insulin. We calculated the proportion of each HbA1c testing frequency (≥1, ≥2, or ≥4 times per year) stratified by 17 administrative regions. Multilevel and multivariate logistic analyses were performed with regional (proportion of farmer population) and individual characteristics (age, sex, income level, duration of diabetes, and most visited medical institution). Overall, 67.3% of the patients received≥1 HbA1c test per year; 37.8% and 6.1% received ≥2 and ≥4 tests per year, respectively. Those managed in secondary-level hospitals or clinics and those living in rural areas were less likely to receive HbA1c testing. Even after adjusting for individual and regional level characteristics, significant area level variation was observed (variance participant coefficients were 7.91%, 9.58%, and 14.43% for testing frequencies of ≥1, ≥2, and ≥4 times a year, respectively). The frequency of HbA1c monitoring is suboptimal in Korea, especially in rural areas. Moreover, significant regional variation was observed, implying a contextual effect. This suggests the need for developing policy actions to improve HbA1c monitoring. In particular, access to HbA1c testing in rural primary care clinics must be improved. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Cloned Hemoglobin Genes Enhance Growth Of Cells

    Science.gov (United States)

    Khosla, Chaitan; Bailey, James E.

    1991-01-01

    Experiments show that portable deoxyribonucleic acid (DNA) sequences incorporated into host cells make them produce hemoglobins - oxygen-binding proteins essential to function of red blood cells. Method useful in several biotechnological applications. One, enhancement of growth of cells at higher densities. Another, production of hemoglobin to enhance supplies of oxygen in cells, for use in chemical reactions requiring oxygen, as additive to serum to increase transport of oxygen, and for binding and separating oxygen from mixtures of gases.

  6. Solid-Phase Extraction of Hemoglobin from Human Whole Blood with a Coordination-Polymer-Derived Composite Material Based on ZnO and Mesoporous Carbon.

    Science.gov (United States)

    Jia, Yuan; Xu, Xinxin; Ou, Jinzhao; Liu, Xiaoxia

    2017-11-13

    A composite material, ZnO@MC, has been synthesized successfully by calcination using a one-dimensional zinc-based coordination polymer as the precursor. In ZnO@MC, ZnO particles with a size of about 5-8 nm are dispersed evenly in a mesoporous carbon matrix. Adsorption experiments at pH 6.8 with 2 mg ZnO@MC as adsorbent illustrated an adsorption efficiency of 92.3 % in 5 mL hemoglobin (Hb) solution with a concentration of 100 mg L -1 . In contrast, the adsorption of bovine serum albumin can almost be ignored under the same conditions. The selectivity originates from a strong Zn II -histidine interaction between ZnO@MC and hemoglobin. The adsorption behavior of hemoglobin on ZnO@MC fits the Temkin model perfectly with a capacity as high as 11646 mg g -1 . The hemoglobin adsorbed on the composite material can be eluted easily with sodium dodecyl sulfate stripping reagent with an extraction efficiency of 87.7 %. Circular dichroism spectra and protein activity studies suggest the structure and biological activity of hemoglobin is the same before and after the adsorption/desorption experiment. Finally, the ZnO@MC composite material was employed to extract hemoglobin from human whole blood without any pretreatment, and gave a very satisfactory result. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Functional importance of PAI-1 glycosylation

    DEFF Research Database (Denmark)

    Christensen, Anni; Naessens, Dominik; Skottrup, Peter

    2001-01-01

    Structure-function studies of plasminogen activator inhibitor-1 (PAI-1) have previously been performed mostly with non-glycosylated material expressed in E. coli. We have now studied the importance of PAI-1 glycosylation for its functional properties. PAI-1 has 3 potential sites for N......-glycosylated PAI-1 could be conferred upon PAI-1 expressed in HEK293 cells by mutational inactivation of one or the other glycosylation site. These findings reveal a novel functional role for glycosylation of a serpin. The glycosylation sites are localised between a-helix H and b-strand 2C and b-strand 3C and a...

  8. Hemoglobin redox reactions and red blood cell aging.

    Science.gov (United States)

    Rifkind, Joseph M; Nagababu, Enika

    2013-06-10

    The physiological mechanism(s) for recognition and removal of red blood cells (RBCs) from circulation after 120 days of its lifespan is not fully understood. Many of the processes thought to be associated with the removal of RBCs involve oxidative stress. We have focused on hemoglobin (Hb) redox reactions, which is the major source of RBC oxidative stress. The importance of Hb redox reactions have been shown to originate in large parts from the continuous slow autoxidation of Hb producing superoxide and its dramatic increase under hypoxic conditions. In addition, oxidative stress has been shown to be associated with redox reactions that originate from Hb reactions with nitrite and nitric oxide (NO) and the resultant formation of highly toxic peroxynitrite when NO reacts with superoxide released during Hb autoxidation. The interaction of Hb, particularly under hypoxic conditions with band 3 of the RBC membrane is critical for the generating the RBC membrane changes that trigger the removal of cells from circulation. These changes include exposure of antigenic sites, increased calcium leakage into the RBC, and the resultant leakage of potassium out of the RBC causing cell shrinkage and impaired deformability. The need to understand the oxidative damage to specific membrane proteins that result from redox reactions occurring when Hb is bound to the membrane. Proteomic studies that can pinpoint the specific proteins damaged under different conditions will help elucidate the cellular aging processes that result in cells being removed from circulation.

  9. Comparison of the gold standard of hemoglobin measurement with the clinical standard (BGA) and noninvasive hemoglobin measurement (SpHb) in small children: a prospective diagnostic observational study.

    Science.gov (United States)

    Wittenmeier, Eva; Bellosevich, Sophia; Mauff, Susanne; Schmidtmann, Irene; Eli, Michael; Pestel, Gunther; Noppens, Ruediger R

    2015-10-01

    Collecting a blood sample is usually necessary to measure hemoglobin levels in children. Especially in small children, noninvasively measuring the hemoglobin level could be extraordinarily helpful, but its precision and accuracy in the clinical environment remain unclear. In this study, noninvasive hemoglobin measurement and blood gas analysis were compared to hemoglobin measurement in a clinical laboratory. In 60 healthy preoperative children (0.2-7.6 years old), hemoglobin was measured using a noninvasive method (SpHb; Radical-7 Pulse Co-Oximeter), a blood gas analyzer (clinical standard, BGAHb; ABL 800 Flex), and a laboratory hematology analyzer (reference method, labHb; Siemens Advia). Agreement between the results was assessed by Bland-Altman analysis and by determining the percentage of outliers. Sixty SpHb measurements, 60 labHb measurements, and 59 BGAHb measurements were evaluated. In 38% of the children, the location of the SpHb sensor had to be changed more than twice for the signal quality to be sufficient. The bias/limits of agreement between SpHb and labHb were -0.65/-3.4 to 2.1 g·dl(-1) . Forty-four percent of the SpHb values differed from the reference value by more than 1 g·dl(-1) . Age, difficulty of measurement, and the perfusion index (PI) had no influence on the accuracy of SpHb. The bias/limits of agreement between BGAHb and labHb were 1.14/-1.6 to 3.9 g·dl(-1) . Furthermore, 66% of the BGAHb values differed from the reference values by more than 1 g·dl(-1) . The absolute mean difference between SpHb and labHb (1.1 g·dl(-1) ) was smaller than the absolute mean difference between BGAHb and labHb (1.5 g·dl(-1) /P = 0.024). Noninvasive measurement of hemoglobin agrees more with the reference method than the measurement of hemoglobin using a blood gas analyzer. However, both methods can show clinically relevant differences from the reference method (ClinicalTrials.gov: NCT01693016). © 2015 John Wiley & Sons Ltd.

  10. Ultrasonic processing for recovery of chicken erythrocyte hemoglobin

    Science.gov (United States)

    Hemoglobin from chicken blood has been shown to be a good substitute for synthetic polymeric flocculants. One stage of processing the blood entails breaking open the cells and releasing the cytoplasmic contents; in the present study, we investigate the use of ultrasonic processing at this stage. Was...

  11. Biophysical basis of hypoxic radioprotection by deoxygenated dextran-hemoglobin

    International Nuclear Information System (INIS)

    Wong, J.T.; Hill, R.P.

    1986-01-01

    Perfusion with deoxygenated dextran-hemoglobin provides an effective method for inducing hypoxic radioprotection of normal tissues during radiation treatment of tumors. In this study, the dependence of P50, the half-saturation pressure of oxygen binding to dextran-hemoglobin, was analyzed as a function of solution temperature and pH. The variation of attainable radioprotection with P50, and with the amount of collateral blood entering into the perfused region, was calculated. Upon perfusion of canine gracilis muscle with deoxygenated dextran-hemoglobin, a rapid onset of extensive venous hypoxia was observed

  12. Modifiers of hemoglobin/oxygen affinity as sensitizers of tumors to radiation

    International Nuclear Information System (INIS)

    Hirst, D.G.; Wood, P.J.

    1987-01-01

    A powerful mechanism in the control of oxygen delivery to tissues is the allosteric modification of hemoglobin. Increased or decreased release of oxygen can be achieved by altering the affinity of hemoglobin for oxygen. Several studies have shown that tumor radiosensitivity is dependent on this relationship. The authors studied affinity changes produced in two distinctly different ways. Tumor bearing mice were given isovolemic exchange blood transfusions with the blood from donor mice which had been exposed to abnormal oxygen tensions, leading to increased or slightly decreased levels of 2,3-diphosphoglycerate (2,3 DPG) in their blood. When the recipient mice were irradiated, those receiving the blood with higher 2,3 DPG levels showed greater tumor sensitivity to radiation. An alternative strategy is the use of drugs which directly alter hemoglobin/oxygen affinity. The authors studied three antihyperlipoproteinemia drugs, all of which have produced markedly reduced affinities in vivo. Preliminary data indicate that the radiosensitization produced by at least one of these compounds is less than would have been expected from the 2,3 DPG experiments

  13. Correlation between Oxygen Saturation and Hemoglobin and Hematokrit Levels in Tetralogy of Fallot Patients

    Directory of Open Access Journals (Sweden)

    Farhatul Inayah Adiputri

    2016-03-01

    Full Text Available Background: Hemoglobin and hematocrit levels increase in Tetralogy of Fallot (TOF but the oxygen saturation declines. Reduced hemoglobin in circulating blood as a parameter of cyanosis does not indicate rising hemoglobin due to the ‘not-working’ hemoglobins that affect the oxygen saturation. Increasing hematocrit is the result of secondary erythrocytosis caused by declining oxygen level in blood, which is related to the oxygen saturation. This study was conducted to find the correlation between oxygen saturation and hemoglobin and hematocrite levels in TOF patients. Methods: This study was undertaken at Dr. Hasan Sadikin General Hospital in the period of January 2011 to December 2012 using the cross-sectional analytic method with total sampling technique. Inclusion criteria were medical records of TOF patients diagnosed based on echocardiography that included data on oxygen saturation, hemoglobin, and hematocrite. Exclusion criteria was the history of red blood transfusion. Results: Thirty medical records of TOF patiens from Dr. Hasan Sadikin General Hospital Bandung were included in this study. Due to skewed data distribution, Spearman correlation test was used to analyze the data. There was a significant negative correlation between oxygen saturation and hematocrit level (r= -0.412; p=0.024 and insignificant correlation between oxygen saturation and hemoglobin (r=-0.329; p= 0.076. Conclusions: There is a weak negative correlation between oxygen saturation and hematocrite levels

  14. Led Astray by Hemoglobin A1c

    Directory of Open Access Journals (Sweden)

    Jean Chen MD

    2016-01-01

    Full Text Available Hemoglobin A1c (A1c is used frequently to diagnose and treat diabetes mellitus. Therefore, it is important be aware of factors that may interfere with the accuracy of A1c measurements. This is a case of a rare hemoglobin variant that falsely elevated a nondiabetic patient’s A1c level and led to a misdiagnosis of diabetes. A 67-year-old male presented to endocrine clinic for further management after he was diagnosed with diabetes based on an elevated A1c of 10.7%, which is approximately equivalent to an average blood glucose of 260 mg/dL. Multiple repeat A1c levels remained >10%, but his home fasting and random glucose monitoring ranged from 92 to 130 mg/dL. Hemoglobin electrophoresis and subsequent genetic analysis diagnosed the patient with hemoglobin Wayne, a rare hemoglobin variant. This variant falsely elevates A1c levels when A1c is measured using cation-exchange high-performance liquid chromatography. When the boronate affinity method was applied instead, the patient’s A1c level was actually 4.7%. Though hemoglobin Wayne is clinically silent, this patient was erroneously diagnosed with diabetes and started on an antiglycemic medication. Due to this misdiagnosis, the patient was at risk of escalation in his “diabetes management” and hypoglycemia. Therefore, it is important that providers are aware of factors that may result in hemoglobin A1c inaccuracy including hemoglobin variants.

  15. Hemoglobin alpha 2 gene +861 G>A polymorphism in Turkish ...

    African Journals Online (AJOL)

    Thalassemia is an inherited blood disorder which is divided into two groups: alpha and beta. HBA1 and HBA2 are the two genes associated with alpha thalassemia. The aim of this study is to investigate abnormal hemoglobin variants of alpha globin gene in healthy abnormal hemoglobin carrying individuals with intact beta ...

  16. Identification of a haptoglobin-hemoglobin complex in the Alaskan Least Cisco (Coregonus sardinella).

    Science.gov (United States)

    Wahl, S M; Boger, J K; Michael, V; Duffy, L K

    1992-01-01

    The hemoglobin and a hemoglobin binding protein have been characterized in the Arctic fish (Coregonus sardinella). The evolutionary significance of the hemoglobin and plasma protein differences between fish and mammals is still unresolved. Blood samples from the Alaskan Least Cisco were separated into plasma and hemoglobin fractions and the proteins in these fractions were analyzed both by alkaline agarose gel electrophoresis, by isolelectric focusing, and by capillary electrophoresis. Staining the plasma proteins gels with o-dianisidine revealed hemoglobin containing protein complexes. A hemoglobin-containing band was observed in hemolyzed plasma which did not migrate with free hemoglobin, and is believed to be hemoglobin-haptoglobin complex. Size exclusion chromatography further characterized the hemoglobin as disassociating freely into dimers, and hemoglobin-haptoglobin complex having a molecular weight greater then 200,000 daltons.

  17. Hemoglobin affinity in Andean rodents

    Directory of Open Access Journals (Sweden)

    HRVOJ OSTOJIC

    2002-01-01

    Full Text Available Blood hemoglobin oxygen affinity (P50 was measured in three Andean species and in the laboratory rat (control, all raised near sea level. Chinchilla lanigera (Molina, 1792 has an altitudinal habitat range from low Andean slopes up to 3000 m., while Chinchilla brevicaudata (Waterhouse, 1848 has an altitudinal range from 3000 to 5000 m. The laboratory type guinea pig, wild type guinea pig (Cavia porcellus, (Waterhouse, 1748, and laboratory rat (Rattus norvegicus were also raised at sea level. The Andean species had high hemoglobin oxygen affinities (low P50 compared with the rat. Chinchilla brevicaudata had a higher affinity than Chinchilla lanigera. The wild type guinea pig had a higher affinity than the laboratory type. As has been shown in other species, this is another example of an inverse correlation between the altitude level and the P50 values. This is the first hemoglobin oxygen affinity study in Chinchilla brevicaudata.

  18. Efficient synthesis of glycosylated phenazine natural products and analogs with DISAL (methyl 3,5-dinitrosalicylate) glycosyl donors

    DEFF Research Database (Denmark)

    Laursen, Jane B.; Petersen, Lars; Jensen, K.J.

    2003-01-01

    Inspired by the occurrence and function of phenazines in natural products, new glycosylated analogs were designed and synthesized. DISAL (methyl 3,5-dinitrosalicylate) glycosyl donors were used in an efficient and easily-handled glycosylation protocol compatible with combinatorial chemistry....... Benzoylated D-glucose, D-galactose and L-quinovose DISAL glycosyl donors were synthesized in high yields and used under mild conditions to glycosylate methyl saphenate and 2-hydroxyphenazine. The glycosides were screened for biological activity and one compound showed inhibitory activity towards topoisomerase...

  19. The Reaction of Oxy Hemoglobin with Nitrite: Mechanism, Antioxidant-Modulated Effect, and Implications for Blood Substitute Evaluation

    Directory of Open Access Journals (Sweden)

    Denisa Hathazi

    2018-02-01

    Full Text Available The autocatalytic reaction between nitrite and the oxy form of globins involves free radicals. For myoglobin (Mb, an initial binding of nitrite to the iron-coordinated oxygen molecule was proposed; the resulting ferrous-peroxynitrate species was not detected, but its decay product, the high-valent ferryl form, was demonstrated in stopped-flow experiments. Reported here are the stopped flow spectra recorded upon mixing oxy Hb (native, as well as chemically-derivatized in the form of several candidates of blood substitutes with a supraphysiological concentration of nitrite. The data may be fitted to a simple kinetic model involving a transient met-aqua form, in contrast to the ferryl detected in the case of Mb in a similar reaction sequence. These data are in line with a previous observation of a transient accumulation of ferryl Hb under auto-catalytic conditions at much lower concentrations of nitrite (Grubina, R. et al. J. Biol. Chem. 2007, 282, 12916. The simple model for fitting the stopped-flow data leaves a small part of the absorbance changes unaccounted for, unless a fourth species is invoked displaying features similar to the oxy and tentatively assigned as ferrous-peroxynitrate. Density functional theory (DFT calculations support this latter assignment. The reaction allows for differentiating between the reactivities of various chemically modified hemoglobins, including candidates for blood substitutes. Polymerization of hemoglobin slows the nitrite-induced oxidation, in sharp contrast to oxidative-stress type reactions which are generally accelerated, not inhibited. Sheep hemoglobin is found to be distinctly more resistant to reaction with nitrite compared to bovine Hb, at large nitrite concentrations (stopped-flow experiments directly observing the oxy + nitrite reaction as well as under auto-catalytic conditions. Copolymerization of Hb with bovine serum albumin (BSA using glutaraldehyde leads to a distinct increase of the lag time

  20. Phase separation of the plasma membrane in human red blood cells as a potential tool for diagnosis and progression monitoring of type 1 diabetes mellitus.

    Science.gov (United States)

    Maulucci, Giuseppe; Cordelli, Ermanno; Rizzi, Alessandro; De Leva, Francesca; Papi, Massimiliano; Ciasca, Gabriele; Samengo, Daniela; Pani, Giovambattista; Pitocco, Dario; Soda, Paolo; Ghirlanda, Giovanni; Iannello, Giulio; De Spirito, Marco

    2017-01-01

    Glycosylation, oxidation and other post-translational modifications of membrane and transmembrane proteins can alter lipid density, packing and interactions, and are considered an important factor that affects fluidity variation in membranes. Red blood cells (RBC) membrane physical state, showing pronounced alterations in Type 1 diabetes mellitus (T1DM), could be the ideal candidate for monitoring the disease progression and the effects of therapies. On these grounds, the measurement of RBC membrane fluidity alterations can furnish a more sensitive index in T1DM diagnosis and disease progression than Glycosylated hemoglobin (HbA1c), which reflects only the information related to glycosylation processes. Here, through a functional two-photon microscopy approach we retrieved fluidity maps at submicrometric scale in RBC of T1DM patients with and without complications, detecting an altered membrane equilibrium. We found that a phase separation between fluid and rigid domains occurs, triggered by systemic effects on membranes fluidity of glycation and oxidation. The phase separation patterns are different among healthy, T1DM and T1DM with complications patients. Blood cholesterol and LDL content are positively correlated with the extent of the phase separation patterns. To quantify this extent a machine learning approach is employed to develop a Decision-Support-System (DSS) able to recognize different fluidity patterns in RBC. Preliminary analysis shows significant differences(pBlood cells is a potential tool for diagnosis and progression monitoring of type 1 diabetes mellitus, and could allow customization and the selection of medical treatments in T1DM in clinical settings, and enable the early detection of complications.

  1. Myth or reality : Hematocrit and hemoglobin differ in trauma

    NARCIS (Netherlands)

    Nijboer, Johanna M. M.; van der Horst, Iwan C. C.; Hendriks, Herman G. D.; ten Duis, Hendrik-Jan; Nijsten, Maarten W. N.

    Background: Estimating blood loss in trauma patients usually involves the determination of hematocrit (Ht) or hemoglobin (Hb). However, in trauma patients, a poorly substantiated habit exists to determine both Ht and Hb in assessing acute blood loss. This suggests that Ht and Hb provide different

  2. PLASMA PROTEIN AND HEMOGLOBIN PRODUCTION

    Science.gov (United States)

    Robscheit-Robbins, F. S.; Miller, L. L.; Whipple, G. H.

    1947-01-01

    Given healthy dogs fed abundant iron and protein-free or low protein diets with sustained anemia and hypoproteinemia, we can study the capacity of these animals to produce simultaneously new hemoglobin and plasma protein. Reserve stores of blood protein-building materials are measurably depleted and levels of 6 to 8 gm. per cent for hemoglobin and 4 to 5 gm. per cent for plasma protein can be maintained for weeks or months depending upon the intake of food proteins or amino acid mixtures. These dogs are very susceptible to infection and various poisons. Dogs tire of these diets and loss of appetite terminates many experiments. Under these conditions (double depletion) standard growth mixtures of essential amino acids are tested to show the response in blood protein output and urinary nitrogen balance. As a part of each tabulated experiment one of the essential amino acids is deleted from the complete growth mixture to compare such response with that of the whole mixture. Methionine, threonine, phenylalanine, and tryptophane when singly eliminated from the complete amino acid mixture do effect a sharp rise in urinary nitrogen. This loss of urinary nitrogen is corrected when the individual amino acid is replaced in the mixture. Histidine, lysine, and valine have a moderate influence upon urinary nitrogen balance toward nitrogen conservation. Leucine, isoleucine, and arginine have minimal or no effect upon urinary nitrogen balance when these individual amino acids are deleted from the complete growth mixture of amino acids during 3 to 4 week periods. Tryptophane and to a less extent phenylalanine and threonine when returned to the amino acid mixture are associated with a conspicuous preponderance of plasma protein output over the hemoglobin output (Table 4). Arginine, lysine, and histidine when returned to the amino acid mixture are associated with a large preponderance of hemoglobin output. Various amino acid mixtures under these conditions may give a positive

  3. Control of mucin-type O-glycosylation

    DEFF Research Database (Denmark)

    Bennett, Eric P; Mandel, Ulla; Clausen, Henrik

    2012-01-01

    residues, is one of the most abundant forms of protein glycosylation in animals. Although most protein glycosylation is controlled by one or two genes encoding the enzymes responsible for the initiation of glycosylation, i.e. the step where the first glycan is attached to the relevant amino acid residue...... in the protein, mucin-type O-glycosylation is controlled by a large family of up to 20 homologous genes encoding UDP-GalNAc:polypeptide GalNAc-transferases (GalNAc-Ts) (EC 2.4.1.41). Therefore, mucin-type O-glycosylation has the greatest potential for differential regulation in cells and tissues. The Gal...

  4. N- and O-glycosylation Analysis of Human C1-inhibitor Reveals Extensive Mucin-type O-Glycosylation.

    Science.gov (United States)

    Stavenhagen, Kathrin; Kayili, H Mehmet; Holst, Stephanie; Koeleman, Carolien A M; Engel, Ruchira; Wouters, Diana; Zeerleder, Sacha; Salih, Bekir; Wuhrer, Manfred

    2018-06-01

    Human C1-inhibitor (C1-Inh) is a serine protease inhibitor and the major regulator of the contact activation pathway as well as the classical and lectin complement pathways. It is known to be a highly glycosylated plasma glycoprotein. However, both the structural features and biological role of C1-Inh glycosylation are largely unknown. Here, we performed for the first time an in-depth site-specific N - and O -glycosylation analysis of C1-Inh combining various mass spectrometric approaches, including C18-porous graphitized carbon (PGC)-LC-ESI-QTOF-MS/MS applying stepping-energy collision-induced dissociation (CID) and electron-transfer dissociation (ETD). Various proteases were applied, partly in combination with PNGase F and exoglycosidase treatment, in order to analyze the (glyco)peptides. The analysis revealed an extensively O -glycosylated N-terminal region. Five novel and five known O -glycosylation sites were identified, carrying mainly core1-type O -glycans. In addition, we detected a heavily O -glycosylated portion spanning from Thr 82 -Ser 121 with up to 16 O -glycans attached. Likewise, all known six N -glycosylation sites were covered and confirmed by this site-specific glycosylation analysis. The glycoforms were in accordance with results on released N -glycans by MALDI-TOF/TOF-MS/MS. The comprehensive characterization of C1-Inh glycosylation described in this study will form the basis for further functional studies on the role of these glycan modifications. © 2018 by The American Society for Biochemistry and Molecular Biology, Inc.

  5. Dried Blood Spot Collection of Health Biomarkers to Maximize Participation in Population Studies

    Science.gov (United States)

    Ostler, Michael W.; Porter, James H.; Buxton, Orfeu M.

    2014-01-01

    Biomarkers are directly-measured biological indicators of disease, health, exposures, or other biological information. In population and social sciences, biomarkers need to be easy to obtain, transport, and analyze. Dried Blood Spots meet this need, and can be collected in the field with high response rates. These elements are particularly important in longitudinal study designs including interventions where attrition is critical to avoid, and high response rates improve the interpretation of results. Dried Blood Spot sample collection is simple, quick, relatively painless, less invasive then venipuncture, and requires minimal field storage requirements (i.e. samples do not need to be immediately frozen and can be stored for a long period of time in a stable freezer environment before assay). The samples can be analyzed for a variety of different analytes, including cholesterol, C-reactive protein, glycosylated hemoglobin, numerous cytokines, and other analytes, as well as provide genetic material. DBS collection is depicted as employed in several recent studies. PMID:24513728

  6. Long-Term Single and Joint Effects of Excessive Daytime Napping on the HOMA-IR Index and Glycosylated Hemoglobin

    Science.gov (United States)

    Li, Xue; Pang, Xiuyu; Zhang, Qiao; Qu, Qiannuo; Hou, Zhigang; Liu, Zhipeng; Lv, Lin; Na, Guanqiong; Zhang, Wei; Sun, Changhao; Li, Ying

    2016-01-01

    Abstract This prospective cohort study was conducted to assess the duration of daytime napping and its effect combined with night sleep deprivation on the risk of developing high HOMA-IR (homeostasis model assessment of insulin resistance) index and disadvantageous changes in glycosylated hemoglobin (HbA1c) levels. A total of 5845 diabetes-free subjects (2736 women and 3109 men), 30 to 65 years of age, were targeted for this cohort study since 2008. Multiple adjusted Cox regression models were performed to evaluate the single and joint effects of daytime napping on the risk of an elevated HbA1c level and high HOMA-IR index. After an average of 4.5 years of follow-up, >30 minutes of daytime napping was significantly associated with an increased risk of an elevated HbA1c level (>6.5%) in men and women (all P trend HOMA-IR index in the entire cohort, men, and women were 1.33 (1.10–1.62), 1.46 (1.08–1.98), and 1.47 (1.12–1.91), respectively. The combination of sleep deprivation with no naps or >30 minutes napping and the combination of no sleep deprivation with >30 minutes daytime napping were all associated with an HbA1c level >6.5% (HR = 2.08, 95% CI = 1.24–3.51; HR = 4.00, 95% CI = 2.03–7.90; and HR = 2.05, 95% CI = 1.29–3.27, respectively). No sleep deprivation combined with >30 minutes daytime napping correlated with a high risk of an HbA1c level between 5.7% and 6.4% and high HOMA-IR index (HR = 2.12, 95% CI = 1.48–3.02; and HR = 1.35, 95% CI = 1.10–1.65, respectively). Daytime napping >30 minutes was associated with a high risk of an elevated HbA1c level and high HOMA-IR index. No sleep deprivation combined with napping >30 minutes carries a risk of abnormal glucose metabolism. Sleep deprivation combined with brief daytime napping HOMA-IR index. PMID:26844520

  7. [Influence of mastication on the amount of hemoglobin in human brain tissue].

    Science.gov (United States)

    Sasaki, A

    2001-03-01

    The purpose of this study was to investigate the influence of mastication on the amount of hemoglobin in human brain tissue. Nine healthy volunteers (6 males and 3 females) participated in this study. They underwent two tasks: 1) at rest, 2) gum-chewing. In seven of the nine (4 males and 3 females), experimental occlusal interference was applied to the first molar of the mandibule on the habitual masticatory side. They underwent the gum-chewing task. To evaluate the amount of hemoglobin, both the hemoglobin oxygenation state and blood volume during gum-chewing were measured in the frontal region, using near-infrared spectroscopy. The amount of total-hemoglobin (blood volume) and oxyhemoglobin of subjects significantly increased during gum-chewing (p experimental occlusal interference was imposed on the subject, the amount of them significantly decreased compared with subjects without experimental occlusal interference (p < 0.05). The results suggested that increases of cerebral blood flow in the frontal region were not due to the mandibular movement, and that human brain activity caused by mastication was not only in the cortical masticatory area but also in the frontal region.

  8. Prediction of glycosylation sites using random forests

    Directory of Open Access Journals (Sweden)

    Hirst Jonathan D

    2008-11-01

    Full Text Available Abstract Background Post translational modifications (PTMs occur in the vast majority of proteins and are essential for function. Prediction of the sequence location of PTMs enhances the functional characterisation of proteins. Glycosylation is one type of PTM, and is implicated in protein folding, transport and function. Results We use the random forest algorithm and pairwise patterns to predict glycosylation sites. We identify pairwise patterns surrounding glycosylation sites and use an odds ratio to weight their propensity of association with modified residues. Our prediction program, GPP (glycosylation prediction program, predicts glycosylation sites with an accuracy of 90.8% for Ser sites, 92.0% for Thr sites and 92.8% for Asn sites. This is significantly better than current glycosylation predictors. We use the trepan algorithm to extract a set of comprehensible rules from GPP, which provide biological insight into all three major glycosylation types. Conclusion We have created an accurate predictor of glycosylation sites and used this to extract comprehensible rules about the glycosylation process. GPP is available online at http://comp.chem.nottingham.ac.uk/glyco/.

  9. Hallmarks of glycosylation in cancer.

    Science.gov (United States)

    Munkley, Jennifer; Elliott, David J

    2016-06-07

    Aberrant glycosylation plays a fundamental role in key pathological steps of tumour development and progression. Glycans have roles in cancer cell signalling, tumour cell dissociation and invasion, cell-matrix interactions, angiogenesis, metastasis and immune modulation. Aberrant glycosylation is often cited as a 'hallmark of cancer' but is notably absent from both the original hallmarks of cancer and from the next generation of emerging hallmarks. This review discusses how glycosylation is clearly an enabling characteristic that is causally associated with the acquisition of all the hallmark capabilities. Rather than aberrant glycosylation being itself a hallmark of cancer, another perspective is that glycans play a role in every recognised cancer hallmark.

  10. Correlations of Hemoglobin Level and Perioperative Blood Transfusion with the Prognosis of Gastric Cancer: A Retrospective Study.

    Science.gov (United States)

    Wu, Gang; Zhang, Dai-Yang; Duan, Yu-Han; Zhang, Ying-Qiong; Cui, Xian-Nian; Luo, Zheng

    2017-05-23

    BACKGROUND This study was designed to explore the correlations of hemoglobin level (Hb) and perioperative blood transfusion with the prognosis of gastric cancer (GC). MATERIAL AND METHODS Our study consisted of 210 patients with GC who all received a D2 radical operation. These patients were assigned into three groups: 68 cases in group A (blood transfusion >5 U); 59 cases in group B (blood transfusion blood transfusion). A 5-year follow-up was conducted to evaluate the disease-free survival of the patients. Univariate analysis was performed to reveal the relationship between the indicators and the patients with GC. Kaplan-Meier method was employed to analyze the survival rate of patients, and Cox regression analysis was applied to determine the independent prognostic factors of GC. RESULTS The univariate analysis indicated that age, perioperative blood transfusion amount, TNM staging, maximal tumor diameter, differentiation degree and invasion degree were associated with the prognosis of GC. The Kaplan-Meier curve showed that the disease-free survival rate was declined in the patients who were older, those received more amount of blood transfusion, those in advanced TNM staging, those had larger tumor diameter, and those with decreased degree of differentiation and invasion. Cox regression analysis indicated that perioperative blood transfusion, maximal tumor diameter and invasion degree were the independent factors affecting disease-free survival of the GC. CONCLUSIONS Our study revealed that large amount of perioperative blood transfusion leads to poor prognosis of GC.

  11. Association between blood glucose level derived using the oral glucose tolerance test and glycated hemoglobin level.

    Science.gov (United States)

    Kim, Hyoung Joo; Kim, Young Geon; Park, Jin Soo; Ahn, Young Hwan; Ha, Kyoung Hwa; Kim, Dae Jung

    2016-05-01

    Glycated hemoglobin (HbA1c) is widely used as a marker of glycemic control. Translation of the HbA1c level to an average blood glucose level is useful because the latter figure is easily understood by patients. We studied the association between blood glucose levels revealed by the oral glucose tolerance test (OGTT) and HbA1c levels in a Korean population. A total of 1,000 subjects aged 30 to 64 years from the Cardiovascular and Metabolic Diseases Etiology Research Center cohort were included. Fasting glucose levels, post-load glucose levels at 30, 60, and 120 minutes into the OGTT, and HbA1c levels were measured. Linear regression of HbA1c with mean blood glucose levels derived using the OGTT revealed a significant correlation between these measures (predicted mean glucose [mg/dL] = 49.4 × HbA1c [%] - 149.6; R (2) = 0.54, p Glucose (ADAG) study and Diabetes Control and Complications Trial (DCCT) cohort. Discrepancies between our results and those of the ADAG study and DCCT cohort may be attributable to differences in the test methods used and the extent of insulin secretion. More studies are needed to evaluate the association between HbA1c and self monitoring blood glucose levels.

  12. Improvements in or relating to antibodies active against human hemoglobin Asub(1C)

    International Nuclear Information System (INIS)

    Javid, J.; Cerami, A.; Koenig, R.J.; Pettis, P.K.

    1980-01-01

    A method is described for preparing an antibody against human hemoglobin Asub(1c) which is substantially free of cross-reactivity against the human hemoglobins A 0 , Asub(1a) and Asub(1b). The antibodies are collected from cats, goats or sheep following injections of purified hemoglobin Asub(1c) antigen since these animals do not naturally produce hemoglobin Asub(1c). A radioimmunoassay method is also described whereby these antibodies are used to determine the quantity of hemoglobin Asub(1c) in blood samples. This is a useful technique in the diagnosis of diabetes mellitus. (U.K.)

  13. The Relationship Between Preoperative Hemoglobin Concentration, Use of Hospital Resources, and Outcomes in Cardiac Surgery.

    Science.gov (United States)

    Hallward, George; Balani, Nikhail; McCorkell, Stuart; Roxburgh, James; Cornelius, Victoria

    2016-08-01

    Preoperative anemia is an established risk factor associated with adverse perioperative outcomes after cardiac surgery. However, limited information exists regarding the relationship between preoperative hemoglobin concentration and outcomes. The aim of this study was to investigate how outcomes are affected by preoperative hemoglobin concentration in a cohort of patients undergoing cardiac surgery. A retrospective, observational cohort study. A single-center tertiary referral hospital. The study comprised 1,972 adult patients undergoing elective and nonelective cardiac surgery. The independent relationship of preoperative hemoglobin concentration was explored on blood transfusion rates, return to the operating room for bleeding and/or cardiac tamponade, postoperative intensive care unit (ICU) and in-hospital length of stay, and mortality. The overall prevalence of anemia was 32% (629/1,972 patients). For every 1-unit increase in hemoglobin (g/dL), blood transfusion requirements were reduced by 11%, 8%, and 3% for red blood cell units, platelet pools, and fresh frozen plasma units, respectively (adjusted incident rate ratio 0.89 [95% CI 0.87-0.91], 0.92 [0.88-0.97], and 0.97 [0.96-0.99]). For each 1-unit increase in hemoglobin (g/dL), the probability (over time) of discharge from the ICU and hospital increased (adjusted hazard ratio estimates 1.04 [1.00-1.08] and 1.12 [1.12-1.16], respectively). A lower preoperative hemoglobin concentration resulted in increased use of hospital resources after cardiac surgery. Each g/dL unit fall in preoperative hemoglobin concentration resulted in increased blood transfusion requirements and increased postoperative ICU and hospital length of stay. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Molecular characteristics of hemoglobins in blood clam and their immune responses to bacterial infection.

    Science.gov (United States)

    Xu, Bin; Zhang, Yanan; Jing, Zhao; Fan, Tingjun

    2017-06-01

    Bivalve hemoglobins have antibacterial activities, while the underlying mechanisms remain poorly understood. In our study, three full-length cDNAs of hemoglobins from blood clam skHbs were obtained, encoding putative polypeptides of 147, 150, and 152 amino acids, respectively. Predicted advanced protein structures showed that the skHbs had amphipathic antibacterial structures, displayed the typical structural characteristics of proteins with globin-like fold containing numerous alpha-helixes, and forming a homodimeric skHbI and a heterotetrameric skHbII complex. After injected with alive and heat-killed Gram-positive bacteria Bacillus subtilis, the mRNA levels of skHbI and skHbII were both significantly upregulated through increasing the expression of peptidoglycan recognition protein-like (PGRP-like) protein and Toll-like receptor (TLR-like) protein induced by peptidoglycan on the surface of the bacteria, but there were no obvious differences in their protein levels. Besides, reactive oxygen species (ROS) was detected to participate in the resistance to B. subtilis. These implied that skHbs could involve in the innate immune responses to Gram-positive bacterial infection directly with their amphipathic structures and indirectly by increasing ROS production through PGRP triggering Toll pathway. In conclusion, our findings reveal the structural characteristics of skHbs and their mechanism against Gram-positive bacteria thereby providing the molecular evidence for fundamental innate antibacterial activities by invoking respiratory proteins. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Forensic differentiation between peripheral and menstrual blood in cases of alleged sexual assault-validating an immunochromatographic multiplex assay for simultaneous detection of human hemoglobin and D-dimer.

    Science.gov (United States)

    Holtkötter, Hannah; Dias Filho, Claudemir Rodrigues; Schwender, Kristina; Stadler, Christian; Vennemann, Marielle; Pacheco, Ana Claudia; Roca, Gabriela

    2018-05-01

    Sexual assault is a serious offense and identification of body fluids originating from sexual activity has been a crucial aspect of forensic investigations for a long time. While reliable tests for the detection of semen and saliva have been successfully implemented into forensic laboratories, the detection of other body fluids, such as vaginal or menstrual fluid, is more challenging. Especially, the discrimination between peripheral and menstrual blood can be highly relevant for police investigations because it provides potential evidence regarding the issue of consent. We report the forensic validation of an immunochromatographic test that allows for such discrimination in forensic stains, the SERATEC PMB test, and its performance on real casework samples. The PMB test is a duplex test combining human hemoglobin and D-dimer detection and was developed for the identification of blood and menstrual fluid, both at the crime scene and in the laboratory. The results of this study showed that the duplex D-dimer/hemoglobin assay reliably detects the presence of human hemoglobin and identifies samples containing menstrual fluid by detecting the presence of D-dimers. The method distinguished between menstrual and peripheral blood in a swab from a historical artifact and in real casework samples of alleged sexual assaults. Results show that the development of the new duplex test is a substantial progress towards analyzing and interpreting evidence from sexual assault cases.

  16. Binding characteristics of arylamine, o-toluidine, in rodent blood proteins, hemoglobin and albumin

    International Nuclear Information System (INIS)

    DeBord, D.G.; Swearengin, T.F.; Booth-Jones, A.B.; Wissinger, L.A.

    1991-01-01

    o-Toluidine (OT), an arylamine used as an anti-oxidant in the tire and rubber industry, is a suspect human carcinogen. In order to develop a method for biological monitoring of OT, the authors have examined the binding characteristics of OT to the blood proteins, albumin (Alb) and hemoglobin (Hb). Male Sprague-Dawley rats were treated with 10, 20, 40, 50, or 100 mg/kg [ 14 C0]-OT ip and terminated at 2, 4, 8, 18, or 24 hrs. Alb and Hb were isolated from the blood. OT binding was determined by radioactivity associated with Alb and Hb. Maximum OT binding occurred at 4 hrs for Alb and 24 hrs for Hb. The radioactivity associated with Alb was 2x greater than that associated with Hb at 4 hrs, and approximately 30% greater at 24 hrs. Similar OT binding to Alb was observed at the 50 and 100 mg/kg doses, while for Hb maximum binding was seen at 100 mg/kg. Extended time points were studied to determine which blood protein would be more useful for biological monitoring purposes. Rats were treated with 100 mg/kg bw [ 14 C]-OT and terminated at 1, 2 and 4 wks. The remaining radioactivity associated with Alb was 12% after 1 wk, and < 2% after 2 and 4 wks. Conversely, the radioactivity associated with Hb was 64% after 1 wk, 52% by 2 wks, and 24% by 4 wks. These results suggest that Hb may be more useful than Alb as a biological monitoring tool for OT

  17. A nanocluster-based fluorescent sensor for sensitive hemoglobin detection.

    Science.gov (United States)

    Yang, Dongqin; Meng, Huijie; Tu, Yifeng; Yan, Jilin

    2017-08-01

    In this report, a fluorescence sensor for sensitive detection of hemoglobin was developed. Gold nanoclusters were first synthesized with bovine serum albumin. It was found that both hydrogen peroxide and hemoglobin could weakly quench the fluorescence from the gold nanoclusters, but when these two were applied onto the nanolcusters simultaneously, a much improved quenching was resulted. This enhancing effect was proved to come from the catalytic generation of hydroxyl radical by hemoglobin. Under an optimized condition, the quenching linearly related to the concentration of hemoglobin in the range of 1-250nM, and a limit of detection as low as 0.36nM could be obtained. This provided a sensitive means for the quantification of Hb. The sensor was then successfully applied for blood analyses with simple sample pretreatment. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Glycosylation-Based Serum Biomarkers for Cancer Diagnostics and Prognostics.

    Science.gov (United States)

    Kirwan, Alan; Utratna, Marta; O'Dwyer, Michael E; Joshi, Lokesh; Kilcoyne, Michelle

    2015-01-01

    Cancer is the second most common cause of death in developed countries with approximately 14 million newly diagnosed individuals and over 6 million cancer-related deaths in 2012. Many cancers are discovered at a more advanced stage but better survival rates are correlated with earlier detection. Current clinically approved cancer biomarkers are most effective when applied to patients with widespread cancer. Single biomarkers with satisfactory sensitivity and specificity have not been identified for the most common cancers and some biomarkers are ineffective for the detection of early stage cancers. Thus, novel biomarkers with better diagnostic and prognostic performance are required. Aberrant protein glycosylation is well known hallmark of cancer and represents a promising source of potential biomarkers. Glycoproteins enter circulation from tissues or blood cells through active secretion or leakage and patient serum is an attractive option as a source for biomarkers from a clinical and diagnostic perspective. A plethora of technical approaches have been developed to address the challenges of glycosylation structure detection and determination. This review summarises currently utilised glycoprotein biomarkers and novel glycosylation-based biomarkers from the serum glycoproteome under investigation as cancer diagnostics and for monitoring and prognostics and includes details of recent high throughput and other emerging glycoanalytical techniques.

  19. The narrow therapeutic window of glycated hemoglobin and assay variability.

    Science.gov (United States)

    Hosseini, S S; Bibler, I; Charles, M A

    1999-12-01

    Glycated hemoglobin is measured by a variety of assays, each of which has a unique normal level. Our purpose is to show that among the different assays available in the United States, using the same patient's blood sample, assay results may vary widely and may more or less easily achieve a glycated hemoglobin value within the normal range. The following assays were compared using the same patient's blood sample for each pair of assays: glycohemoglobin affinity assay (GHB Reader; Isolab, Akron, OH) versus gel electrophoresis assay (n = 76); Isolab versus ion capture assay (IMX; Abbott Laboratories, Irving, TX) (n = 57); monoclonal antibody assay (DCA2000; Bayer Diagnostics, Pittsburgh, PA) versus IMX (n = 100); and high-performance liquid chromatography (HPLC) assay (Bio-Rad Variant A1c; Bio-Rad Laboratories, Richmond, CA) versus IMX assay (n = 55). Our analyses indicate that a relative ranking can be established for the ease of achieving a normal glycated hemoglobin level. The ranking indicates that the most stringent or difficult assays for achieving a normal level are the Isolab and DCA2000 assays. The intermediate assays are the IMX and Bio-Rad Variant, and the easiest method for achieving a normal value is the gel electrophoresis assay. Our results indicate that various glycated hemoglobin assays vary widely and are associated with more or less difficulty for an individual patient to achieve a glycated hemoglobin level within the normal range. These results are especially significant with respect to (1) the clinically narrow therapeutic window of glycated hemoglobin values in type 1 diabetes to avoid rapidly advancing severe hypoglycemia rates and chronic microvascular complication rates, and (2) the glycated hemoglobin threshold for rapidly advancing macrovascular disease in both type 1 and type 2 patients.

  20. Quality evaluation of four hemoglobin screening methods in a blood donor setting along with their comparative cost analysis in an Indian scenario

    Directory of Open Access Journals (Sweden)

    Tondon Rashmi

    2009-01-01

    Full Text Available Background: Despite the wide range of methods available for measurement of hemoglobin, no single technique has emerged as the most appropriate and ideal for a blood donation setup. Materials and Methods: A prospective study utilizing 1014 blood samples was carried out in a blood donation setting for quality evaluation of four methods of hemoglobin estimation along with cost analysis: Hematology cell analyzer (reference, HCS, CuSO4 method and HemoCue. Results: Mean value of HemoCue (mean ± SD = 14.7 ± 1.49 g/dl was higher by 0.24 compared to reference (mean ± SD = 13.8 ± 1.52 g/dl but not statistically significant ( P > 0.05. HemoCue proved to be the best technique (sensitivity 99.4% and specificity 84.4% whereas HCS was most subjective with 25.2% incorrect estimations. CuSO4 proved to be good with 7.9% false results. Comparative cost analysis of each method was calculated to be 35 INR/test for HemoCue, 0.76 INR /test for HCS and 0.06-0.08 INR /test for CuSO4. Conclusion: CuSO4 method gives accurate results, if strict quality control is applied. HemoCue is too expensive to be used as a primary screening method in an economically restricted country like India.

  1. Theoretical model for optical oximetry at the capillary level: exploring hemoglobin oxygen saturation through backscattering of single red blood cells

    Science.gov (United States)

    Liu, Rongrong; Spicer, Graham; Chen, Siyu; Zhang, Hao F.; Yi, Ji; Backman, Vadim

    2017-02-01

    Oxygen saturation (sO2) of red blood cells (RBCs) in capillaries can indirectly assess local tissue oxygenation and metabolic function. For example, the altered retinal oxygenation in diabetic retinopathy and local hypoxia during tumor development in cancer are reflected by abnormal sO2 of local capillary networks. However, it is far from clear whether accurate label-free optical oximetry (i.e., measuring hemoglobin sO2) is feasible from dispersed RBCs at the single capillary level. The sO2-dependent hemoglobin absorption contrast present in optical scattering signal is complicated by geometry-dependent scattering from RBCs. We present a numerical study of backscattering spectra from single RBCs based on the first-order Born approximation, considering practical factors: RBC orientations, size variation, and deformations. We show that the oscillatory spectral behavior of RBC geometries is smoothed by variations in cell size and orientation, resulting in clear sO2-dependent spectral contrast. In addition, this spectral contrast persists with different mean cellular hemoglobin content and different deformations of RBCs. This study shows for the first time the feasibility of, and provides a theoretical model for, label-free optical oximetry at the single capillary level using backscattering-based imaging modalities, challenging the popular view that such measurements are impossible at the single capillary level.

  2. High-altitude adaptations in vertebrate hemoglobins

    DEFF Research Database (Denmark)

    Weber, Roy E.

    2007-01-01

    Vertebrates at high altitude are subjected to hypoxic conditions that challenge aerobic metabolism. O2 transport from the respiratory surfaces to tissues requires matching between the O2 loading and unloading tensions and theO2-affinity of blood, which is an integrated function of hemoglobin......, birds and ectothermic vertebrates at high altitude....

  3. Functional importance of PAI-1 glycosylation

    DEFF Research Database (Denmark)

    Christensen, Anni; Naessens, Dominik; Skottrup, Peter

    susceptible PAI-1 variant was not necessarily the one used when raising the antibody. This and other observations indicated that the carbohydrate moieties or the glycosylation sites are unlikely to be part of the epitopes for these antibodies. The antibody susceptibility characteristic for non......Structure-function studies of plasminogen activator inhibitor-1 (PAI-1) have previously been performed mostly with non-glycosylated material expressed in E. coli. We have now studied the importance of PAI-1 glycosylation for its functional properties. PAI-1 has 3 potential sites for N......-linked glycosylation. Biochemical analysis of PAI-1 variants with substitutions of the Asn residues in each of these sites and expression in human embryonic kidney 293 (HEK293) cells showed that only Asn211 and Asn 267, but not Asn331 are glycosylated, and revealed a differential composition of the carbohydrate...

  4. Polynitroxylated Pegylated Hemoglobin-A Novel, Small Volume Therapeutic for Traumatic Brain Injury Resuscitation: Comparison to Whole Blood and Dose Response Evaluation.

    Science.gov (United States)

    Brockman, Erik C; Jackson, Travis C; Dixon, C Edward; Bayɪr, Hülya; Clark, Robert S B; Vagni, Vincent; Feldman, Keri; Byrd, Catherine; Ma, Li; Hsia, Carleton; Kochanek, Patrick M

    2017-04-01

    Resuscitation with polynitroxylated pegylated hemoglobin (PNPH), a pegylated bovine hemoglobin decorated with nitroxides, eliminated the need for fluid administration, reduced intracranial pressure (ICP) and brain edema, and produced neuroprotection in vitro and in vivo versus Lactated Ringer's solution (LR) in experimental traumatic brain injury (TBI) plus hemorrhagic shock (HS). We hypothesized that resuscitation with PNPH would improve acute physiology versus whole blood after TBI+HS and would be safe and effective across a wide dosage range. Anesthetized mice underwent controlled cortical impact and severe HS to mean arterial pressure (MAP) of 25-27 mm Hg for 35 min, then were resuscitated with PNPH, autologous whole blood, or LR. Markers of acute physiology, including mean arterial blood pressure (MAP), heart rate (HR), blood gases/chemistries, and brain oxygenation (PbtO 2 ), were monitored for 90 min on room air followed by 15 min on 100% oxygen. In a second experiment, the protocol was repeated, except mice were resuscitated with PNPH with doses between 2 and 100 mL/kg. ICP and 24 h %-brain water were evaluated. PNPH-resuscitated mice had higher MAP and lower HR post-resuscitation versus blood or LR (p < 0.01). PNPH-resuscitated mice, versus those resuscitated with blood or LR, also had higher pH and lower serum potassium (p < 0.05). Blood-resuscitated mice, however, had higher PbtO 2 versus those resuscitated with LR and PNPH, although PNPH had higher PbtO 2 versus LR (p < 0.05). PNPH was well tolerated across the dosing range and dramatically reduced fluid requirements in all doses-even 2 or 5 mL/kg (p < 0.001). ICP was significantly lower in PNPH-treated mice for most doses tested versus in LR-treated mice, although %-brain water did not differ between groups. Resuscitation with PNPH, versus resuscitation with LR or blood, improved MAP, HR, and ICP, reduced acidosis and hyperkalemia, and was well tolerated and effective

  5. A new polyethyleneglycol-derivatized hemoglobin derivative with decreased oxygen affinity and limited toxicity.

    Science.gov (United States)

    Zolog, Oana; Mot, Augustin; Deac, Florina; Roman, Alina; Fischer-Fodor, Eva; Silaghi-Dumitrescu, Radu

    2011-01-01

    A new protocol is described for derivatization of hemoglobin with polyethyleneglycol (PEG) via reaction of the unmodified native hemoglobin with an activated amine-reacting polyethylene glycol derivative which, unlike protocols previously described, leads to formation of a peptide bond between hemoglobin and PEG. Dioxygen binding and peroxide reactivities of the derivatized hemoglobin are examined, and found to be within reasonable limits, with the particular observation that, unlike with a few other derivatization protocols, the dioxygen affinity is slightly lower than that of native Hb. In cell culture tests (human umbilical vein epithelial cells, HUVEC), the derivatization protocol induces no toxic effect. These results show promise towards applicability for production of hemoglobin-based blood substitutes.

  6. Evaluation on the detection limit of blood hemoglobin using photolepthysmography based on path-length optimization

    Science.gov (United States)

    Sun, Di; Guo, Chao; Zhang, Ziyang; Han, Tongshuai; Liu, Jin

    2016-10-01

    The blood hemoglobin concentration's (BHC) measurement using Photoplethysmography (PPG), which gets blood absorption to near infrared light from the instantaneous pulse of transmitted light intensity, has not been applied to the clinical use due to the non-enough precision. The main challenge might be caused of the non-enough stable pulse signal when it's very weak and it often varies in different human bodies or in the same body with different physiological states. We evaluated the detection limit of BHC using PPG as the measurement precision level, which can be considered as a best precision result because we got the relative stable subject's pulse signals recorded by using a spectrometer with high signal-to-noise ratio (SNR) level, which is about 30000:1 in short term. Moreover, we optimized the used pathlength using the theory based on optimum pathlength to get a better sensitivity to the absorption variation in blood. The best detection limit was evaluated as about 1 g/L for BHC, and the best SNR of pulse for in vivo measurement was about 2000:1 at 1130 and 1250 nm. Meanwhile, we conclude that the SNR of pulse signal should be better than 400:1 when the required detection limit is set to 5 g/L. Our result would be a good reference to the BHC measurement to get a desired BHC measurement precision of real application.

  7. Identificação de variantes de hemoglobina em doadores de sangue Identification of hemoglobin variants in blood donor

    Directory of Open Access Journals (Sweden)

    Ana C. Bonini-Domingos

    2004-03-01

    Full Text Available Hemoglobinopathies are the most common genetic diseases and affect a great number of individuals in the world, with diverse clinical complications ranging from the almost unnoticeable to lethal consequences. In Brazil the occurrence of hemoglobinopathies is very frequent and influenced by the ethnical groups that are the basis of populations in different regions. The phenotype may be influenced by environmental and genetic factors and by migration. An understanding of these genetic diseases is important for the health and quality of life of the population. In this work we assessed the presence of Hb variants in blood donors from São José do Rio Preto and region, and we observed the occurrence of variants including Hb S and Hb C but in particular the so-called "S-Like" variants. Good determination of the forms of variant hemoglobins is very important to give better guidance to blood donors and their families, and to improve the quality of blood transfusion.

  8. Antidiabetic Activity of Aqueous Leaves Extract of Sesbania sesban (L) Merr. in Streptozotocin Induced Diabetic Rats

    Science.gov (United States)

    Pandhare, Ramdas B.; Sangameswaran, B.; Mohite, Popat B.; Khanage, Shantaram G.

    2011-01-01

    The aqueous leaves extract of Sesbania sesban (L) Merr. (Family: Fabaceae) was evaluated for its antidiabetic potential on normal and streptozotocin (STZ)-induced diabetic rats. In the chronic model, the aqueous extract was administered to normal and STZ- induced diabetic rats at the doses of 250 and 500 mg/kg body weight (b.w.) p.o. per day for 30 days. The fasting Blood Glucose Levels (BGL), serum insulin level and biochemical data such as glycosylated hemoglobin, Total Cholesterol (TC), Triglycerides (TG), High Density Lipoproteins (HDL) and Low Density Lipoproteins (LDL) were evaluated and all were compared to that of the known anti-diabetic drug glibenclamide (0.25 mg/kg b.w.). The statistical data indicated significant increase in the body weight, liver glycogen, serum insulin and HDL levels and decrease in blood glucose, glycosylated hemoglobin, total cholesterol and serum triglycerides when compared with glibenclamide. Thus the aqueous leaves extract of Sesbania sesban had beneficial effects in reducing the elevated blood glucose level and lipid profile of STZ-induced diabetic rats. PMID:23407749

  9. Endocrine pancreatic function changes after acute pancreatitis.

    Science.gov (United States)

    Wu, Deqing; Xu, Yaping; Zeng, Yue; Wang, Xingpeng

    2011-10-01

    This study aimed to investigate the impairment of pancreatic endocrine function and the associated risk factors after acute pancreatitis (AP). Fifty-nine patients were subjected to tests of pancreatic function after an attack of pancreatitis. The mean time after the event was 3.5 years. Pancreatic endocrine function was evaluated by fasting blood glucose (FBG), glycosylated hemoglobin, fasting blood insulin, and C-peptide. Homeostasis model assessment was used to evaluate insulin resistance and islet β-cell function. Pancreatic exocrine function was evaluated by fecal elastase 1. Factors that could influence endocrine function were also investigated. Nineteen patients (32%) were found to have elevated FBG, whereas 5 (8%) had abnormal glycosylated hemoglobin levels. The levels of FBG, fasting blood insulin, and C-peptide were higher in patients than in controls (P endocrine insufficiency. Pancreatic exocrine functional impairment was found at the same time. Endocrine functional impairment with insulin resistance was found in patients after AP. Obesity, hyperlipidemia, and diabetes-related symptoms increased the likelihood of developing functional impairment after AP.

  10. Impact of hemoglobin nitrite to nitric oxide reductase on blood transfusion for resuscitation from hemorrhagic shock

    Directory of Open Access Journals (Sweden)

    Chad Brouse

    2015-01-01

    Full Text Available Background: Transfusion of blood remains the gold standard for fluid resuscitation from hemorrhagic shock. Hemoglobin (Hb within the red blood cell transports oxygen and modulates nitric oxide (NO through NO scavenging and nitrite reductase. Aims: This study was designed to examine the effects of incorporating a novel NO modulator, RRx-001, on systemic and microvascular hemodynamic response after blood transfusion for resuscitation from hemorrhagic shock in a hamster window chamber model. In addition, to RRx-001 the role of low dose of nitrite (1 × 10−9 moles per animal supplementation after resuscitation was studied. Materials and Methods: Severe hemorrhage was induced by arterial controlled bleeding of 50% of the blood volume (BV and the hypovolemic state was maintained for 1 h. The animals received volume resuscitation by an infusion of 25% of BV using fresh blood alone or with added nitrite, or fresh blood treated with RRx-001 (140 mg/kg or RRx-001 (140 mg/kg with added nitrite. Systemic and microvascular hemodynamics were followed at baseline and at different time points during the entire study. Tissue apoptosis and necrosis were measured 8 h after resuscitation to correlate hemodynamic changes with tissue viability. Results: Compared to resuscitation with blood alone, blood treated with RRx-001 decreased vascular resistance, increased blood flow and functional capillary density immediately after resuscitation and preserved tissue viability. Furthermore, in RRx-001 treated animals, both mean arterial pressure (MAP and met Hb were maintained within normal levels after resuscitation (MAP >90 mmHg and metHb <2%. The addition of nitrite to RRx-001 did not significantly improve the effects of RRx-001, as it increased methemoglobinemia and lower MAP. Conclusion: RRx-001 alone enhanced perfusion and reduced tissue damage as compared to blood; it may serve as an adjunct therapy to the current gold standard treatment for resuscitation from

  11. The effect of a standardized protocol for iron supplementation to blood donors low in hemoglobin concentration.

    Science.gov (United States)

    Magnussen, Karin; Bork, Nanna; Asmussen, Lisa

    2008-04-01

    Iron deficiency leading to low hemoglobin concentration (cHb) is a common problem for blood donors as well as for blood banks. A standardized protocol offering iron supplementation based on P-ferritin determination may help to reduce the problem and retain donors. This was a prospective study where 879 blood donors, presenting with cHb at or below the limit of acceptance for donation, were included. The predonation cHb result was read after donation. The donors received 50 iron tablets (JernC or Ferrochel, 100 or 25 mg elemental iron, respectively), and samples for P-ferritin, mean corpuscular volume, and control of cHb were secured. Based on a P-ferritin level of less than 60 microg per L, 20 iron tablets were offered after all following donations. Mean cHb was 7.6 mmol per L (122 g/L) and 8.2 mmol per L (132 g/L) in women and men, respectively. In 80 percent of the women and 48 percent of the men, iron stores were low (P-ferritin protocol offering iron supplementation and simple oral and written advice based on P-ferritin measurements is effective in normalizing cHb and retaining donors presenting with cHb at or below the limit of acceptance for donation.

  12. Packed red blood cell transfusion causes greater hemoglobin rise at a lower starting hemoglobin in patients with subarachnoid hemorrhage.

    Science.gov (United States)

    Naidech, Andrew M; Kahn, Marc J; Soong, Wayne; Green, David; Batjer, H Hunt; Bleck, Thomas P

    2008-01-01

    Each unit of packed red blood cells (PRBCs) is expected to raise circulating hemoglobin (HGB) by approximately 1 g/dL. There are few data on modifiers of this relationship other than gender and body mass index (BMI). We recorded HGB before and after PRBC transfusion in a retrospective cohort of 103 patients and a prospective cohort of 93 patients with subarachnoid hemorrhage (SAH). In the retrospective cohort, 48 of 103 patients were transfused, and in the prospective cohort, 56 of 93 patients were transfused. In both groups, lower pre-transfusion HGB was associated with a larger increase in HGB (P rise in HGB (P < 0.001) after correction for number of units of PRBCs given, gender, and BMI in repeated measures analysis. Pre-transfusion HGB explained an additional 12% of variance in the data (P < 0.001). In both cohorts, the magnitude of the effect was similar. In patients with SAH, transfusion at lower HGB leads to a greater increase in HGB. Transfusion at lower HGB may be relatively more cost-effective, and this should be balanced against any potential benefit from higher HGB in SAH. One rather than 2 units of PRBCs are likely to be sufficient for most HGB targets after SAH, especially in patients with more severe anemia.

  13. Effects of iron supplementation on red blood cell hemoglobin content in pregnancy

    Directory of Open Access Journals (Sweden)

    Margreet Schoorl

    2012-11-01

    Full Text Available Although a mild degree of anemia is common in the third trimester of pregnancy, it remains a challenge to establish whether a decrease in hemoglobin (Hb concentration is physiological or pathological. The World Health Organization suggested a Hb concentration of 110 g/L to discriminate anemia. Several European investigators recommended Hb cut-off values of between 101-110 g/L. The aim of this study was to establish short-term effects of iron supplementation on the hemoglobin content of reticulocytes (Ret-He and red blood cells (RBC-He in case of suspected iron deficient erythropoiesis (IDE in the third trimester of pregnancy. Twenty-five subjects with suspected IDE during pregnancy (Hb ≤110g/L, Ret-He <29.6 pg, zinc protoporphyrin >75 mol/mol hem participated in the study. After iron supplementation, reticulocyte counts increased from 0.061±0.015x1012/L to 0.079±0.026x1012/L and Ret-He increased from 23.6±2.8 pg to 28.3±2.6 pg (P=<0.001. RBC-He increased from 26.9±1.9 pg to 27.4±1.8 pg (not significant, NS and Ret-He/RBC-He ratio increased from 0.97±0.06 towards 1.07±0.05 (P=<0.001. Hb concentrations demonstrated an obvious increase from 105±6 g/L towards 115±5 g/L (P≤0.001 after supplementation. An obvious increase in RBC distribution width was observed from 45.0±3.6 fL towards 52.3±7.0 fL (P≤0.001. We recommend that Ret-He and Ret-He/RBC-He ratio be integrated into the protocols for anemia screening and for monitoring effects of iron supplementation during pregnancy. In particular, the parameters should be considered in subjects with Hb results in the controversial range of 101-108 g/L.

  14. Mechanisms of the adjuvant effect of hemoglobin in experimental peritonitis. VII. Hemoglobin does not inhibit clearance of Escherichia coli from the peritoneal cavity

    International Nuclear Information System (INIS)

    Dunn, D.L.; Barke, R.A.; Lee, J.T. Jr.; Condie, R.M.; Humphrey, E.W.; Simmons, R.L.

    1983-01-01

    Hemoglobin has been shown to be a potent adjuvant in experimental Escherichia coli peritonitis, although a satisfactory mechanistic rationale is still obscure. Hemoglobin has been thought to impair intraperitoneal neutrophil function, delay clearance of bacteria from the peritoneal cavity by the normal absorptive mechanisms, or directly enhance bacterial growth. Using highly purified stroma-free hemoglobin (SFHgb), we have largely discounted any direct effect of hemoglobin on peritoneal white blood cell function. In the present study, we confirmed that uncontrolled proliferation of bacteria takes place in the presence of hemoglobin in the peritoneal cavity. Nonviable 5-iododeoxyuridine 125 I-labelled bacteria were then used to directly study peritoneal clearance kinetics, eliminating the problem of bacterial growth. SFHgb had no influence on the removal of intraperitoneal bacteria. The rate of bloodstream appearance of radiolabel was similar with or without intraperitoneal SFHgb. Thus, SFHgb does not prevent clearance of bacteria from the peritoneal cavity by interfering with normal host clearance mechanisms. SFHgb may act as a bacterial growth adjuvant, either by serving as a bacterial nutrient or by suitably modifying the environment so that extensive bacterial proliferation can occur. The latter hypothesis appears to be an area in which investigation concerning the adjuvant effect of hemoglobin may prove most fruitful

  15. Metabolic control in patients with type 2 diabetes mellitus in a public hospital in Peru: a cross-sectional study in a low-middle income country.

    Science.gov (United States)

    Huayanay-Espinoza, Irma Elizabeth; Guerra-Castañon, Felix; Lazo-Porras, María; Castaneda-Guarderas, Ana; Thomas, Nimmy Josephine; Garcia-Guarniz, Ana-Lucia; Valdivia-Bustamante, Augusto A; Málaga, Germán

    2016-01-01

    The objective of this study was to assess patients' achievement of ADA (American Diabetes Association) guideline recommendations for glycosylated hemoglobin, lipid profile, and blood pressure in a type 2 diabetes mellitus (T2DM) outpatient clinic in a low-middle income country (LMIC) setting. This is a descriptive cross-sectional study with 123 ambulatory T2DM patients who are being treated at a public hospital in Lima, Peru. Data was gathered via standardized interviews, clinical surveys, and anthropomorphic measurements for each patient. Blood samples were drawn in fasting state for measures of glucose, glycosylated hemoglobin (HbA1c), and lipid profile. Laboratory parameters and blood pressure were evaluated according to ADA recommendations. Of the 123 patients, 81 were women and the mean age was 61.8 years. Glycemic control was abnormal in 82 (68.33%) participants, and 45 (37.50%) were unable to control their blood pressure. Lipid profile was abnormal in 73 (60.83%) participants. Only nine (7.50%) participants fulfilled ADA recommendations for glycemic, blood pressure, and lipid control. Amongst individuals with type 2 diabetes, there was poor attainment of the ADA recommendations (HbA1c, blood pressure and LDL-cholesterol) for ambulatory T2DM patients. Interventions are urgently needed in order to prevent long-term diabetic complications.

  16. Engineering the oxygen sensing regulation results in an enhanced recombinant human hemoglobin production by Saccharomyces cerevisiae

    DEFF Research Database (Denmark)

    Martinez Ruiz, José Luis; Liu, Lifang; Petranovic, Dina

    2015-01-01

    Efficient production of appropriate oxygen carriers for transfusions (blood substitutes or artificial blood) has been pursued for many decades, and to date several strategies have been used, from synthetic polymers to cell-free hemoglobin carriers. The recent advances in the field of metabolic en...... the transcription factor HAP1, which resulted in an increase of the final recombinant active hemoglobin titer exceeding 7% of the total cellular protein....

  17. Engineering Mammalian Mucin-type O-Glycosylation in Plants

    DEFF Research Database (Denmark)

    Yang, Zhang; Drew, Damian P; Jørgensen, Bodil

    2012-01-01

    -glycans are attached to proteins, and which structures are formed, difficult. Because plants are devoid of GalNAc-type O-glycosylation, we have assessed requirements for establishing human GalNAc O-glycosylation de novo in plants with the aim of developing cell systems with custom-designed O-glycosylation capacity...... was glycosylated with up to three and five GalNAc residues when co-expressed with GalNAc-T2 and a combination of GalNAc-T2 and GalNAc-T4, respectively, as determined by mass spectrometry. O-Glycosylation was furthermore demonstrated on a tandem repeat of MUC16 and interferon a2b. In plants, prolines in certain...... classes of proteins are hydroxylated and further substituted with plant-specific O-glycosylation; unsubstituted hydroxyprolines were identified in our MUC1 construct. In summary, this study demonstrates that mammalian type O-glycosylation can be established in plants and that plants may serve as a host...

  18. Resveratrol, a natural phytoalexin: A therapeutic promise for ...

    African Journals Online (AJOL)

    into 5 groups: control, control+resveratrol, diabetic, diabetic+resveratrol and diabetic+ glyclazide. The antidiabetic effect of oral administration of. RSV (5mg kg/b.wt) for 45days was evidenced from the improvement in the levels of blood glucose, glycosylated hemoglobin and the calculated homeostasis model assessment of ...

  19. Trans-species Engineering of Glycosylated Therapeutic Proteins

    DEFF Research Database (Denmark)

    Yang, Zhang

    important to address. Whenever glycosylation has been found to be an important PTM for function or bioactivity, human therapeutics have generally been produced in mammalian Chinese hamster ovary (CHO) cell line. Oglycosylation is one of the most complex regulated PTMs of proteins but also one of the least...... understood. Currently, mammalian cells are required for human O-glycosylation. Increasing efforts have been devoted to engineering non-mammalian cells for production of recombinant proteins with “human-like” glycosylation. Substantial success has been achieved with designed N-glycosylation in both lower......Recombinant expression of therapeutic proteins is one of the major tasks in modern biomedicine. One of the most important factors with respect to therapeutic use in human is posttranslational modifications (PTMs) of the recombinant proteins, of which protein glycosylation is by far the most...

  20. Phase separation of the plasma membrane in human red blood cells as a potential tool for diagnosis and progression monitoring of type 1 diabetes mellitus.

    Directory of Open Access Journals (Sweden)

    Giuseppe Maulucci

    Full Text Available Glycosylation, oxidation and other post-translational modifications of membrane and transmembrane proteins can alter lipid density, packing and interactions, and are considered an important factor that affects fluidity variation in membranes. Red blood cells (RBC membrane physical state, showing pronounced alterations in Type 1 diabetes mellitus (T1DM, could be the ideal candidate for monitoring the disease progression and the effects of therapies. On these grounds, the measurement of RBC membrane fluidity alterations can furnish a more sensitive index in T1DM diagnosis and disease progression than Glycosylated hemoglobin (HbA1c, which reflects only the information related to glycosylation processes. Here, through a functional two-photon microscopy approach we retrieved fluidity maps at submicrometric scale in RBC of T1DM patients with and without complications, detecting an altered membrane equilibrium. We found that a phase separation between fluid and rigid domains occurs, triggered by systemic effects on membranes fluidity of glycation and oxidation. The phase separation patterns are different among healthy, T1DM and T1DM with complications patients. Blood cholesterol and LDL content are positively correlated with the extent of the phase separation patterns. To quantify this extent a machine learning approach is employed to develop a Decision-Support-System (DSS able to recognize different fluidity patterns in RBC. Preliminary analysis shows significant differences(p<0.001 among healthy, T1DM and T1DM with complications patients. The development of an assay based on Phase separation of the plasma membrane of the Red Blood cells is a potential tool for diagnosis and progression monitoring of type 1 diabetes mellitus, and could allow customization and the selection of medical treatments in T1DM in clinical settings, and enable the early detection of complications.

  1. Evaluation of the i-STAT point-of-care capillary whole blood hematocrit and hemoglobin: Comparison to the Siemens RAPIDLab 1200, Sysmex XE5000, and manual spun hematocrit.

    Science.gov (United States)

    Rudolf, Joseph; Douglass, Joseph; Baron, Jason; Lewandrowski, Kent

    2015-06-15

    Conductivity based point-of-care hematocrit with calculated hemoglobin devices serves an important role in clinical scenarios where time sensitive transfusion decisions are necessary. However, questions about the appropriateness of conductivity based assays in certain patient populations (patients on cardiopulmonary bypass and those receiving high volumes of intravenous fluids or autologous blood transfusions) have been raised. The clinical suitability of POC devices for these applications necessitates that they be accurate and that the results are interchangeable with central laboratory methods. We performed hematocrit and hemoglobin analysis on 225 clinical samples using the i-STAT instrument, a standard reference method for hematocrit (manual spun) and other common methods on both cardiopulmonary bypass and non-cardiopulmonary bypass patients. The i-STAT hematocrit and hemoglobin showed close agreement to comparison methods with minimal bias. Median test results were not clinically or statistically different between those measured on the i-STAT and those measured using the manual spun hematocrit reference method (p=0.4085, Wilcoxon signed rank test) or the Sysmex photometric hemoglobin method (p=0.2728, Wilcoxon signed rank test). The results on the i-STAT were statistically different from those obtained on the Sysmex for hematocrit (phemoglobin (phematocrit and hemoglobin performs well when compared to the hematocrit reference method and other common methods for both hematocrit and hemoglobin. Some differences between non-reference methods may be observed, but these were not considered clinically significant. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Complete Blood Count (For Parents)

    Science.gov (United States)

    ... Kids Deal With Injections and Blood Tests Blood Culture Anemia Blood Test: Basic Metabolic Panel (BMP) Blood Test: Hemoglobin Basic Blood Chemistry Tests Word! Complete Blood Count (CBC) Medical Tests and Procedures ( ...

  3. Human macrophage hemoglobin-iron metabolism in vitro

    International Nuclear Information System (INIS)

    Custer, G.; Balcerzak, S.; Rinehart, J.

    1982-01-01

    An entirely in vitro technique was employed to characterize hemoglobin-iron metabolism by human macrophages obtained by culture of blood monocytes and pulmonary alveolar macrophages. Macrophages phagocytized about three times as many erythrocytes as monocytes and six times as many erythrocytes as pulmonary alveolar macrophages. The rate of subsequent release of 59 Fe to the extracellular transferrin pool was two- to fourfold greater for macrophages as compared to the other two cell types. The kinetics of 59 Fe-transferrin release were characterized by a relatively rapid early phase (hours 1-4) followed by a slow phase (hours 4-72) for all three cell types. Intracellular movement of iron was characterized by a rapid shift from hemoglobin to ferritin that was complete with the onset of the slow phase of extracellular release. A transient increase in 59 Fe associated with an intracellular protein eluting with transferrin was also observed within 1 hour after phagocytosis. The process of hemoglobin-iron release to extracellular transferrin was inhibited at 4 degrees C but was unaffected by inhibitory of protein synthesis, glycolysis, microtubule function, and microfilament function. These data emphasize the rapidity of macrophage hemoglobin iron metabolism, provide a model for characterization of this process in vitro, and in general confirm data obtained utilizing in vivo animal models

  4. Lower versus higher hemoglobin threshold for transfusion in septic shock.

    Science.gov (United States)

    Holst, Lars B; Haase, Nicolai; Wetterslev, Jørn; Wernerman, Jan; Guttormsen, Anne B; Karlsson, Sari; Johansson, Pär I; Aneman, Anders; Vang, Marianne L; Winding, Robert; Nebrich, Lars; Nibro, Helle L; Rasmussen, Bodil S; Lauridsen, Johnny R M; Nielsen, Jane S; Oldner, Anders; Pettilä, Ville; Cronhjort, Maria B; Andersen, Lasse H; Pedersen, Ulf G; Reiter, Nanna; Wiis, Jørgen; White, Jonathan O; Russell, Lene; Thornberg, Klaus J; Hjortrup, Peter B; Müller, Rasmus G; Møller, Morten H; Steensen, Morten; Tjäder, Inga; Kilsand, Kristina; Odeberg-Wernerman, Suzanne; Sjøbø, Brit; Bundgaard, Helle; Thyø, Maria A; Lodahl, David; Mærkedahl, Rikke; Albeck, Carsten; Illum, Dorte; Kruse, Mary; Winkel, Per; Perner, Anders

    2014-10-09

    Blood transfusions are frequently given to patients with septic shock. However, the benefits and harms of different hemoglobin thresholds for transfusion have not been established. In this multicenter, parallel-group trial, we randomly assigned patients in the intensive care unit (ICU) who had septic shock and a hemoglobin concentration of 9 g per deciliter or less to receive 1 unit of leukoreduced red cells when the hemoglobin level was 7 g per deciliter or less (lower threshold) or when the level was 9 g per deciliter or less (higher threshold) during the ICU stay. The primary outcome measure was death by 90 days after randomization. We analyzed data from 998 of 1005 patients (99.3%) who underwent randomization. The two intervention groups had similar baseline characteristics. In the ICU, the lower-threshold group received a median of 1 unit of blood (interquartile range, 0 to 3) and the higher-threshold group received a median of 4 units (interquartile range, 2 to 7). At 90 days after randomization, 216 of 502 patients (43.0%) assigned to the lower-threshold group, as compared with 223 of 496 (45.0%) assigned to the higher-threshold group, had died (relative risk, 0.94; 95% confidence interval, 0.78 to 1.09; P=0.44). The results were similar in analyses adjusted for risk factors at baseline and in analyses of the per-protocol populations. The numbers of patients who had ischemic events, who had severe adverse reactions, and who required life support were similar in the two intervention groups. Among patients with septic shock, mortality at 90 days and rates of ischemic events and use of life support were similar among those assigned to blood transfusion at a higher hemoglobin threshold and those assigned to blood transfusion at a lower threshold; the latter group received fewer transfusions. (Funded by the Danish Strategic Research Council and others; TRISS ClinicalTrials.gov number, NCT01485315.).

  5. Antidiabetic effect of Chloroxylon swietenia bark extracts on streptozotocin induced diabetic rats

    Directory of Open Access Journals (Sweden)

    B. Jayaprasad

    2016-03-01

    Full Text Available Diabetes has been increasing at an alarming rate around the world, and experts have relied on remedies from the utilization of ancient drugs that are essentially derived from plants. The present study aimed to evaluate the antidiabetic potential of Chloroxylon swietenia bark extracts on streptozotocin induced diabetic rats. Diabetes was induced in male albino Wistar rats by single intraperitoneal injection of streptozotocin (STZ (50 mg/kg b.w.. The diabetic rats were administered orally with C. swietenia bark (CSB methanolic (CSBMEt and aqueous (CSBAEt (250 mg/kg b.w. extracts and glibenclamide (600 µg/kg b.w. by intragastric intubation for 45 days. The result showed a heavy loss in weight, increase in blood glucose and glycosylated hemoglobin level, and decline in plasma insulin and total hemoglobin content. Furthermore, glucose-6-phosphatase and fructose-1,6-bis phosphatase were found to be increased whereas hexokinase and glycogen contents were decreased in STZ induced diabetic rats. CSBAEt, CSBMEt and glibenclamide treated diabetic rats showed moderate reduction in blood glucose and glycosylated hemoglobin levels; in addition, plasma insulin and hemoglobin levels were elevated. The altered activities of carbohydrate metabolizing enzymes and liver glycogen were improved remarkably. CSBMEt results were comparable to the standard drug glibenclamide. The present findings support the usage of the plant extracts for the traditional treatment of diabetes.

  6. Determination of Human Hemoglobin Derivatives.

    Science.gov (United States)

    Attia, Atef M M; Ibrahim, Fatma A A; Abd El-Latif, Noha A; Aziz, Samir W; Abdelmottaleb Moussa, Sherif A; Elalfy, Mohsen S

    2015-01-01

    The levels of the inactive hemoglobin (Hb) pigments [such as methemoglobin (metHb), carboxyhemoglobin (HbCO) and sulfohemoglobin (SHb)] and the active Hb [in the oxyhemoglobin (oxyHb) form] as well as the blood Hb concentration in healthy non pregnant female volunteers were determined using a newly developed multi-component spectrophotometric method. The results of this method revealed values of SHb% in the range (0.0727-0.370%), metHb% (0.43-1.0%), HbCO% (0.4-1.52%) and oxyHb% (97.06-98.62%). Furthermore, the results of this method revealed values of blood Hb concentration in the range (12.608-15.777 g/dL). The method is highly sensitive, accurate and reproducible.

  7. Porcine dentin sialoprotein glycosylation and glycosaminoglycan attachments.

    Science.gov (United States)

    Yamakoshi, Yasuo; Nagano, Takatoshi; Hu, Jan Cc; Yamakoshi, Fumiko; Simmer, James P

    2011-02-03

    Dentin sialophosphoprotein (Dspp) is a multidomain, secreted protein that is critical for the formation of tooth dentin. Mutations in DSPP cause inherited dentin defects categorized as dentin dysplasia type II and dentinogenesis imperfecta type II and type III. Dentin sialoprotein (Dsp), the N-terminal domain of dentin sialophosphoprotein (Dspp), is a highly glycosylated proteoglycan, but little is known about the number, character, and attachment sites of its carbohydrate moieties. To identify its carbohydrate attachment sites we isolated Dsp from developing porcine molars and digested it with endoproteinase Glu-C or pronase, fractionated the digestion products, identified fractions containing glycosylated peptides using a phenol sulfuric acid assay, and characterized the glycopeptides by N-terminal sequencing, amino acid analyses, or LC/MSMS. To determine the average number of sialic acid attachments per N-glycosylation, we digested Dsp with glycopeptidase A, labeled the released N-glycosylations with 2-aminobenzoic acid, and quantified the moles of released glycosylations by comparison to labeled standards of known concentration. Sialic acid was released by sialidase digestion and quantified by measuring β-NADH reduction of pyruvic acid, which was generated stoichiometrically from sialic acid by aldolase. To determine its forms, sialic acid released by sialidase digestion was labeled with 1,2-diamino-4,5-methyleneoxybenzene (DMB) and compared to a DMB-labeled sialic acid reference panel by RP-HPLC. To determine the composition of Dsp glycosaminoglycan (GAG) attachments, we digested Dsp with chondroitinase ABC and compared the chromotagraphic profiles of the released disaccharides to commercial standards. N-glycosylations were identified at Asn37, Asn77, Asn136, Asn155, Asn161, and Asn176. Dsp averages one sialic acid per N-glycosylation, which is always in the form of N-acetylneuraminic acid. O-glycosylations were tentatively assigned at Thr200, Thr216 and Thr

  8. Porcine dentin sialoprotein glycosylation and glycosaminoglycan attachments

    Directory of Open Access Journals (Sweden)

    Yamakoshi Fumiko

    2011-02-01

    Full Text Available Abstract Background Dentin sialophosphoprotein (Dspp is a multidomain, secreted protein that is critical for the formation of tooth dentin. Mutations in DSPP cause inherited dentin defects categorized as dentin dysplasia type II and dentinogenesis imperfecta type II and type III. Dentin sialoprotein (Dsp, the N-terminal domain of dentin sialophosphoprotein (Dspp, is a highly glycosylated proteoglycan, but little is known about the number, character, and attachment sites of its carbohydrate moieties. Results To identify its carbohydrate attachment sites we isolated Dsp from developing porcine molars and digested it with endoproteinase Glu-C or pronase, fractionated the digestion products, identified fractions containing glycosylated peptides using a phenol sulfuric acid assay, and characterized the glycopeptides by N-terminal sequencing, amino acid analyses, or LC/MSMS. To determine the average number of sialic acid attachments per N-glycosylation, we digested Dsp with glycopeptidase A, labeled the released N-glycosylations with 2-aminobenzoic acid, and quantified the moles of released glycosylations by comparison to labeled standards of known concentration. Sialic acid was released by sialidase digestion and quantified by measuring β-NADH reduction of pyruvic acid, which was generated stoichiometrically from sialic acid by aldolase. To determine its forms, sialic acid released by sialidase digestion was labeled with 1,2-diamino-4,5-methyleneoxybenzene (DMB and compared to a DMB-labeled sialic acid reference panel by RP-HPLC. To determine the composition of Dsp glycosaminoglycan (GAG attachments, we digested Dsp with chondroitinase ABC and compared the chromotagraphic profiles of the released disaccharides to commercial standards. N-glycosylations were identified at Asn37, Asn77, Asn136, Asn155, Asn161, and Asn176. Dsp averages one sialic acid per N-glycosylation, which is always in the form of N-acetylneuraminic acid. O-glycosylations were

  9. SLC39A8 Deficiency: A Disorder of Manganese Transport and Glycosylation.

    Science.gov (United States)

    Park, Julien H; Hogrebe, Max; Grüneberg, Marianne; DuChesne, Ingrid; von der Heiden, Ava L; Reunert, Janine; Schlingmann, Karl P; Boycott, Kym M; Beaulieu, Chandree L; Mhanni, Aziz A; Innes, A Micheil; Hörtnagel, Konstanze; Biskup, Saskia; Gleixner, Eva M; Kurlemann, Gerhard; Fiedler, Barbara; Omran, Heymut; Rutsch, Frank; Wada, Yoshinao; Tsiakas, Konstantinos; Santer, René; Nebert, Daniel W; Rust, Stephan; Marquardt, Thorsten

    2015-12-03

    SLC39A8 is a membrane transporter responsible for manganese uptake into the cell. Via whole-exome sequencing, we studied a child that presented with cranial asymmetry, severe infantile spasms with hypsarrhythmia, and dysproportionate dwarfism. Analysis of transferrin glycosylation revealed severe dysglycosylation corresponding to a type II congenital disorder of glycosylation (CDG) and the blood manganese levels were below the detection limit. The variants c.112G>C (p.Gly38Arg) and c.1019T>A (p.Ile340Asn) were identified in SLC39A8. A second individual with the variants c.97G>A (p.Val33Met) and c.1004G>C (p.Ser335Thr) on the paternal allele and c.610G>T (p.Gly204Cys) on the maternal allele was identified among a group of unresolved case subjects with CDG. These data demonstrate that variants in SLC39A8 impair the function of manganese-dependent enzymes, most notably β-1,4-galactosyltransferase, a Golgi enzyme essential for biosynthesis of the carbohydrate part of glycoproteins. Impaired galactosylation leads to a severe disorder with deformed skull, severe seizures, short limbs, profound psychomotor retardation, and hearing loss. Oral galactose supplementation is a treatment option and results in complete normalization of glycosylation. SLC39A8 deficiency links a trace element deficiency with inherited glycosylation disorders. Copyright © 2015 The American Society of Human Genetics. Published by Elsevier Inc. All rights reserved.

  10. Biochemical Importance of Glycosylation of Plasminogen Activator Inhibitor-1

    DEFF Research Database (Denmark)

    Gils, Ann; Pedersen, Katrine Egelund; Skottrup, Peter

    2003-01-01

    The serpin plasminogen activator inhibitor-1 (PAI-1) is a potential target for anti-thrombotic and anti-cancer therapy. PAI-1 has 3 potential sites for N-linked glycosylation. We demonstrate here that PAI-1 expressed recombinantly or naturally by human cell lines display a heterogeneous glycosyla......The serpin plasminogen activator inhibitor-1 (PAI-1) is a potential target for anti-thrombotic and anti-cancer therapy. PAI-1 has 3 potential sites for N-linked glycosylation. We demonstrate here that PAI-1 expressed recombinantly or naturally by human cell lines display a heterogeneous...... with the glycosylation sites could be excluded as explanation for the differential reactivity. The latency transition of non-glycosylated, but not of glycosylated PAI-1, was strongly accelerated by a non-ionic detergent. The different biochemical properties of glycosylated and non-glycosylated PAI-1 depended...

  11. Glycosylation: a hallmark of cancer?

    Science.gov (United States)

    Vajaria, Bhairavi N; Patel, Prabhudas S

    2017-04-01

    The hallmarks of cancer are characterized by functional capabilities that allow cancer cells to survive, proliferate and disseminate during the multistep tumorigenesis. Cancer being a cellular disease, changes in cellular glycoproteins play an important role in malignant transformation and cancer progression. The present review summarizes various studies that depicted correlation of glycosylation with tumor initiation, progression and metastasis, which are helpful in early diagnosis, disease monitoring and prognosis. The results are further strengthened by our reports, which depicted alterations in sialylation and fucosylation in different cancers. Alterations in glycosyltransferases are also involved in formation of various tumor antigens (e.g. Sialyl Lewis x) which serves as ligand for the cell adhesion molecule, selectin which is involved in adhesion of cancer cells to vascular endothelium and thus contributes to hematogenous metastasis. Increased glycosylation accompanied by alterations in glycosyltranferases, glycosidases, glycans and mucins (MUC)s are also involved in loss of E-cadherin, a key molecule implicated in metastatic dissemination of cells. The present review also summarizes the correlation of glycosylation with all the hallmarks of cancer. The enormous progress in the design of novel inhibitors of pathway intermediates of sialylation and fucosylation can prove wonders in combating the dreadful disease. The results provide the evidence that altered glycosylation is linked to tumor initiation, progression and metastasis. Hence, it can be considered as a new hallmark of cancer development and strategies to develop novel glycosylation targeted molecules should be strengthened.

  12. The Effect of Resistance Training on Cardio-Metabolic Factors in Males with Type 2 Diabetes

    Directory of Open Access Journals (Sweden)

    Ghalavand

    2014-10-01

    Full Text Available Background Diabetes is one of the most important metabolic diseases in the world and exercise is a common advice to manage diabetes and reduce its complications. Objectives The aim of this study was to investigate the effect of resistance training on blood glucose, blood pressure and resting heart rate in males with type 2 diabetes. Materials and Methods In this semi-experimental study, 20 males with type 2 diabetes with mean age of 46 ± 3.4 years old who met the inclusion criteria were selected. The participants were randomly assigned into resistance training (n = 10 and control (n = 10 groups. Resistance exercise training program was performed for eight weeks, three sessions per week. Cardiovascular and biochemical parameters were measured before and after the intervention. To analyze the measured parameters changes t-test was used at P ≤ 0.05 significance level. Results After eight weeks, a significant decrease in fasting blood sugar (P = 0.002, glycosylated hemoglobin (P = 0.025 and systolic blood pressure (P = 0.022 was observed in the resistance group. In addition, there was a significant difference in blood sugar (P = 0.003 and glycosylated hemoglobin (P = 0.031 between the two groups. Conclusions Findings of this study confirmed the positive influence of resistance training to control blood glucose and blood pressure in males with type 2 diabetes.

  13. [Hemoglobin variants in Colombian patients referred to discard hemoglobinopathies].

    Science.gov (United States)

    Romero-Sánchez, Consuelo; Gómez Gutiérrez, Alberto; Duarte, Yurani; Amazo, Constanza; Manosalva, Clara; Chila M, Lorena; Casas-Gómez, María Consuelo; Briceño Balcázar, Ignacio

    2015-10-01

    Oxygen transport is altered in hemoglobinopathies. To study the distribution of hemoglobinopathies in Andean subjects without African ancestry. We analyzed blood samples of 1,407 subjects aged 18 to 59 years (58% females), living in the central Andean region of Colombia, referred to discard hemoglobinopathies. The frequency and type of hemoglobinopathy was established by capillary and agarose gel electrophoresis. The frequency of hemoglobinopathies was 34.5% and higher among females. The structural variants found were: AS-heterozygous hemoglobin (8.1%), homozygous SS (3.7%), heterozygous SC (2.2%), AC heterozygotes (0.5%) and heterozygous AE (0.3%). Quantitative variants found were Hb A-Beta thalassemia (13.91%) and Hb H (0.06%), Beta-thalassemia heterozygotes C (0.88%), S-Beta thalassemia heterozygotes (6.07%) and compound heterozygous SC/Beta thalassemia (0.25%), with a persistence of fetal hemoglobin 0. Composite thalassemia was also found in 31%. All techniques showed good correlation and capillary electrophoresis demonstrated a greater detection of hemoglobin variants. The frequency of hemoglobin variants in the analyzed population was high, which is an important public health indicator. The most common hemoglobin variant was HbA/Increased structural Hb A2 and the mos frequent structural hemoglobinopathy was sickle cell trait. Capillary electrophoresis can discern any Hb variants present in the population.

  14. Correlation between Glycated Hemoglobin and Triglyceride Level in Type 2 Diabetes Mellitus.

    Science.gov (United States)

    Naqvi, Syeda; Naveed, Shabnam; Ali, Zeeshan; Ahmad, Syed Masroor; Asadullah Khan, Raad; Raj, Honey; Shariff, Shoaib; Rupareliya, Chintan; Zahra, Fatima; Khan, Saba

    2017-06-13

    Dyslipidemia is quite prevalent in non-insulin dependent diabetes mellitus. Maintaining tight glycemic along with lipid control plays an essential role in preventing micro- and macro-vascular complications associated with diabetes. The main purpose of the study was to highlight the relationship between glycosylated hemoglobin (HbA1c) and triglyceride levels. This may in turn help in predicting the triglyceride status of type 2 diabetics and therefore identifying patients at increased risk from cardiovascular events. Hypertriglyceridemia is one of the common risk factors for coronary artery disease in type 2 diabetes mellitus (DM). Careful monitoring of the blood glucose level can be used to predict lipid status and can prevent most of the complications associated with the disease. This is a cross-sectional study using data collected from the outpatient diabetic clinic of Jinnah Postgraduate Medical Centre (JPMC) Karachi, Pakistan. Patients of age 18 years and above were recruited from the clinic. A total of consenting 509 patients of type 2 diabetes mellitus were enrolled over a period of 11 months.  For statistical analysis, SPSS Statistics for Windows, Version 17.0 ( IBM Corp, Armonk, New York) was used and Chi-square and Pearson's correlation coefficient was used to find the association between triglyceride and HbA1c. The HbA1c was dichotomized into four groups on the basis of cut-off. Chi-square was used for association between HbA1c with various cut-off values and high triglyceride levels. Odds-ratio and its 95% confidence interval were calculated to estimate the level of risk between high triglyceride levels and HbA1c groups. The p-value triglyceride was evaluated in four different groups of HbA1c, with a cut-off seven, eight, nine and 10 respectively. With HbA1c cut-off value of 7%, 74% patients had high triglycerides and showed a significant association with high triglyceride levels at p index, lifestyle) and health status factors (blood pressure

  15. Competition between folding and glycosylation in the endoplasmic reticulum

    DEFF Research Database (Denmark)

    Holst, B; Bruun, A W; Kielland-Brandt, Morten

    1996-01-01

    Using carboxypeptidase Y in Saccharomyces cerevisiae as a model system, the in vivo relationship between protein folding and N-glycosylation was studied. Seven new sites for N-glycosylation were introduced at positions buried in the folded protein structure. The level of glycosylation of such new...... acceptor sites. In some cases, all the newly synthesized mutant protein was modified at the novel site while in others no modification took place. In the most interesting category of mutants, the level of glycosylation was dependent on the conditions for folding. This shows that folding and glycosylation...

  16. Glucose monitoring as a guide to diabetes management. Critical subject review.

    OpenAIRE

    Koch, B.

    1996-01-01

    PURPOSE: To encourage a balanced approach to blood glucose monitoring in diabetes by a critical review of the history, power and cost of glucose testing. DATA SOURCES: The Cambridge Data Base was searched and was supplemented by a random review of other relevant sources, including textbooks, company pamphlets, and laboratory manuals. STUDY SELECTION: Keywords used were "glucosuria diagnosis," "blood glucose self-monitoring," "glycosylated hemoglobin," and "fructosamine" for the 10-year period...

  17. 1834-IJBCS-Article-Dr Barry Mamoudou Mamoudou+

    African Journals Online (AJOL)

    hp

    of Spirulina on Blood glucose,. Glycosylated Hemoglobin and Lipid. Profile of Male Non-Insulin Dependent. Diabetics. Asian J. Exp. Biol. SCI., 1(1):. 36-46. Branger B, Cadudal JL, Delobel M, Ouoba H,. Yameogo P, Ouedraogo D. 2003. Spiruline as a food supplement in case of infant malnutrition in Burkina-Faso. Arch.

  18. The Greenland shark Somniosus microcephalus-Hemoglobins and ligand-binding properties.

    Directory of Open Access Journals (Sweden)

    Roberta Russo

    Full Text Available A large amount of data is currently available on the adaptive mechanisms of polar bony fish hemoglobins, but structural information on those of cartilaginous species is scarce. This study presents the first characterisation of the hemoglobin system of one of the longest-living vertebrate species (392 ± 120 years, the Arctic shark Somniosus microcephalus. Three major hemoglobins are found in its red blood cells and are made of two copies of the same α globin combined with two copies of three very similar β subunits. The three hemoglobins show very similar oxygenation and carbonylation properties, which are unaffected by urea, a very important compound in marine elasmobranch physiology. They display identical electronic absorption and resonance Raman spectra, indicating that their heme-pocket structures are identical or highly similar. The quaternary transition equilibrium between the relaxed (R and the tense (T states is more dependent on physiological allosteric effectors than in human hemoglobin, as also demonstrated in polar teleost hemoglobins. Similar to other cartilaginous fishes, we found no evidence for functional differentiation among the three isoforms. The very similar ligand-binding properties suggest that regulatory control of O2 transport may be at the cellular level and that it may involve changes in the cellular concentrations of allosteric effectors and/or variations of other systemic factors. The hemoglobins of this polar shark have evolved adaptive decreases in O2 affinity in comparison to temperate sharks.

  19. Blood conservation operations in pediatric cardiac patients: a paradigm shift of blood use.

    Science.gov (United States)

    Karimi, Mohsen; Florentino-Pineda, Ivan; Weatherred, Ted; Qadeer, Ahsan; Rosenberg, Carol Ann; Hudacko, Andrea; Ryu, Duchwan

    2013-03-01

    Red blood cell transfusion is associated with high morbidity in pediatric patients undergoing cardiac operations. The aim of this study was to evaluate the clinical effects and outcomes of blood conservation for our pediatric patients undergoing cardiac operations. We retrospectively analyzed a collected database of 168 pediatric patients who underwent biventricular (BV) and univentricular (UV) cardiac operations from 2006 to 2010. Patients were grouped into no blood conservation (n = 86 [BV = 74, UV = 12]) and blood conservation (n = 82 [BV = 68, UV = 14]) cohorts. There were no statistical differences in age, sex, weight, and preoperative or postoperative hemoglobin levels in the BV groups. Even though the blood conservation group had longer cardiopulmonary bypass (CPB) (p conservation group, there were no statistical differences in age, sex, weight, CPB and cross-clamp times, preoperative and postoperative hemoglobin levels, and red blood cell transfusions despite lower intraoperative hemoglobin levels (p conservation group. Logistic regression analysis demonstrated a significant correlation between intraoperative blood transfusion and increased inotropic score, longer duration on the ventilator, and increased length of hospitalization. Blood conservation in pediatric cardiac operations is associated with fewer ventilator days, lower inotropic scores, and shorter lengths of stay. These findings, in addition to attendant risks and side effects of blood transfusion and the rising cost of safer blood products, justify blood conservation in pediatric cardiac operations. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Blood oxygen saturation determined by transmission spectrophotometry of hemolyzed blood samples

    Science.gov (United States)

    Malik, W. M.

    1967-01-01

    Use of the Lambert-Beer Transmission Law determines blood oxygen saturation of hemolyzed blood samples. This simplified method is based on the difference in optical absorption properties of hemoglobin and oxyhemoglobin.

  1. Hepcidin and hemoglobin content parameters in the diagnosis of iron deficiency in rheumatoid arthritis patients with anemia

    NARCIS (Netherlands)

    Santen, S. van; Dongen-Lases, E.C. van; Vegt, F. de; Laarakkers, C.M.; Riel, P.L. van; Ede, A.E. van; Swinkels, D.W.

    2011-01-01

    OBJECTIVE: To explore the utility of the novel iron indices hepcidin, reticulocyte hemoglobin content (Ret-Hgb), and erythrocyte (red blood cell) hemoglobin content (RBC-Hgb) for detection of iron deficiency in rheumatoid arthritis (RA) patients with anemia and active inflammation and to compare

  2. Metabolic control in patients with type 2 diabetes mellitus in a public hospital in Peru: a cross-sectional study in a low-middle income country

    Directory of Open Access Journals (Sweden)

    Irma Elizabeth Huayanay-Espinoza

    2016-10-01

    Full Text Available Objective The objective of this study was to assess patients’ achievement of ADA (American Diabetes Association guideline recommendations for glycosylated hemoglobin, lipid profile, and blood pressure in a type 2 diabetes mellitus (T2DM outpatient clinic in a low-middle income country (LMIC setting. Methods This is a descriptive cross-sectional study with 123 ambulatory T2DM patients who are being treated at a public hospital in Lima, Peru. Data was gathered via standardized interviews, clinical surveys, and anthropomorphic measurements for each patient. Blood samples were drawn in fasting state for measures of glucose, glycosylated hemoglobin (HbA1c, and lipid profile. Laboratory parameters and blood pressure were evaluated according to ADA recommendations. Results Of the 123 patients, 81 were women and the mean age was 61.8 years. Glycemic control was abnormal in 82 (68.33% participants, and 45 (37.50% were unable to control their blood pressure. Lipid profile was abnormal in 73 (60.83% participants. Only nine (7.50% participants fulfilled ADA recommendations for glycemic, blood pressure, and lipid control. Conclusions Amongst individuals with type 2 diabetes, there was poor attainment of the ADA recommendations (HbA1c, blood pressure and LDL-cholesterol for ambulatory T2DM patients. Interventions are urgently needed in order to prevent long-term diabetic complications.

  3. Defectively N-glycosylated and non-O-glycosylated aminopeptidase N (CD13) is normally expressed at the cell surface and has full enzymatic activity

    DEFF Research Database (Denmark)

    Norén, K; Hansen, Gert Helge; Clausen, H

    1997-01-01

    In order to study the effects of the absence of O-glycosylation and modifications of N-glycosylation on a class II membrane protein, pig and human aminopeptidase N (CD13) were stably expressed in the ldl(D) cell line. This cell line carries a UDP-Gal/UDP-GalNAc-epimerase deficiency which blocks...... the conversion of glucose into galactose derivatives. Thus it is possible in the ldl(D) cell line to selectively block O-glycosylation by the omission of N-acetylgalactoseamine from the culture medium and to alter N-glycosylation by the omission of galactose. In this way selectively altered glycosylated forms...

  4. In vivo integrated photoacoustic and confocal microscopy of hemoglobin oxygen saturation and oxygen partial pressure.

    Science.gov (United States)

    Wang, Yu; Hu, Song; Maslov, Konstantin; Zhang, Yu; Xia, Younan; Wang, Lihong V

    2011-04-01

    We developed dual-modality microscope integrating photoacoustic microscopy (PAM) and fluorescence confocal microscopy (FCM) to noninvasively image hemoglobin oxygen saturation (sO₂) and oxygen partial pressure (pO₂) in vivo in single blood vessels with high spatial resolution. While PAM measures sO₂ by imaging hemoglobin optical absorption at two wavelengths, FCM quantifies pO₂ using phosphorescence quenching. The variations of sO₂ and pO₂ values in multiple orders of vessel branches under hyperoxic (100% oxygen) and normoxic (21% oxygen) conditions correlate well with the oxygen-hemoglobin dissociation curve. In addition, the total concentration of hemoglobin is imaged by PAM at an isosbestic wavelength.

  5. The Reaction of Oxy Hemoglobin with Nitrite

    DEFF Research Database (Denmark)

    Hathazi, Denisa; Scurtu, Florina; Bischin, Cristina

    2018-01-01

    The autocatalytic reaction between nitrite and the oxy form of globins involves free radicals. For myoglobin (Mb), an initial binding of nitrite to the iron-coordinated oxygen molecule was proposed; the resulting ferrous-peroxynitrate species was not detected, but its decay product, the high...... to a simple kinetic model involving a transient met-aqua form, in contrast to the ferryl detected in the case of Mb in a similar reaction sequence. These data are in line with a previous observation of a transient accumulation of ferryl Hb under auto-catalytic conditions at much lower concentrations......-peroxynitrate. Density functional theory (DFT) calculations support this latter assignment. The reaction allows for differentiating between the reactivities of various chemically modified hemoglobins, including candidates for blood substitutes. Polymerization of hemoglobin slows the nitrite-induced oxidation, in sharp...

  6. Protective effect of bioflavonoid myricetin enhances carbohydrate metabolic enzymes and insulin signaling molecules in streptozotocin-cadmium induced diabetic nephrotoxic rats.

    Science.gov (United States)

    Kandasamy, Neelamegam; Ashokkumar, Natarajan

    2014-09-01

    Diabetic nephropathy is the kidney disease that occurs as a result of diabetes. The present study was aimed to evaluate the therapeutic potential of myricetin by assaying the activities of key enzymes of carbohydrate metabolism, insulin signaling molecules and renal function markers in streptozotocin (STZ)-cadmium (Cd) induced diabetic nephrotoxic rats. After myricetin treatment schedule, blood and tissue samples were collected to determine plasma glucose, insulin, hemoglobin, glycosylated hemoglobin and renal function markers, carbohydrate metabolic enzymes in the liver and insulin signaling molecules in the pancreas and skeletal muscle. A significant increase of plasma glucose, glycosylated hemoglobin, urea, uric acid, creatinine, blood urea nitrogen (BUN), urinary albumin, glycogen phosphorylase, glucose-6-phosphatase, and fructose-1,6-bisphosphatase and a significant decrease of plasma insulin, hemoglobin, hexokinase, glucose-6-phosphate dehydrogenase, glycogen and glycogen synthase with insulin signaling molecule expression were found in the STZ-Cd induced diabetic nephrotoxic rats. The administration of myricetin significantly normalizes the carbohydrate metabolic products like glucose, glycated hemoglobin, glycogen phosphorylase and gluconeogenic enzymes and renal function markers with increase insulin, glycogen, glycogen synthase and insulin signaling molecule expression like glucose transporter-2 (GLUT-2), glucose transporter-4 (GLUT-4), insulin receptor-1 (IRS-1), insulin receptor-2 (IRS-2) and protein kinase B (PKB). Based on the data, the protective effect of myricetin was confirmed by its histological annotation of the pancreas, liver and kidney tissues. These findings suggest that myricetin improved carbohydrate metabolism which subsequently enhances glucose utilization and renal function in STZ-Cd induced diabetic nephrotoxic rats. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. CORRELATION OF INPATIENT AND OUTPATIENT MEASURES OF STROKE CARE QUALITY WITHIN VETERANS HEALTH ADMINISTRATION HOSPITALS

    Science.gov (United States)

    Ross, Joseph S.; Arling, Greg; Ofner, Susan; Roumie, Christianne L.; Keyhani, Salomeh; Williams, Linda S.; Ordin, Diana L.; Bravata, Dawn M.

    2011-01-01

    Background Quality of care delivered in the inpatient and ambulatory settings may be correlated within an integrated health system such as the Veterans Health Administration (VHA). We examined the correlation between stroke care quality at hospital discharge and within 6 months post-discharge. Methods Cross-sectional hospital-level correlation analyses of chart-abstracted data for 3467 veterans discharged alive after an acute ischemic stroke from 108 VHA medical centers and 2380 veterans with post-discharge follow-up within 6 months, in fiscal year 2007. Four risk-standardized processes of care represented discharge care quality: prescription of anti-thrombotic and anti-lipidemic therapy, anti-coagulation for atrial fibrillation, and tobacco cessation counseling, along with a composite measure of defect-free care. Five risk-standardized intermediate outcomes represented post-discharge care quality: achievement of blood pressure, low-density lipoprotein (LDL), international normalized ratio (INR), and glycosylated hemoglobin target levels, and delivery of appropriate treatment for post-stroke depression, along with a composite measure of achieved outcomes. Results Median risk-standardized composite rate of defect-free care at discharge was 79%. Median risk-standardized post-discharge rates of achieving goal were 56% for blood pressure, 36% for LDL, 41% for INR, 40% for glycosylated hemoglobin, and 39% for depression management and the median risk-standardized composite six-month outcome rate was 44%. The hospital composite rate of defect-free care at discharge was correlated with meeting the LDL goal (r=0.31; p=0.007) and depression management (r=0.27; p=0.03) goal, but was not correlated with blood pressure, INR, or glycosylated hemoglobin goals, nor with the composite measure of achieved post-discharge outcomes (p-values >0.15). Conclusions Hospital discharge care quality was not consistently correlated with ambulatory care quality. PMID:21719771

  8. Spin Label Studies of the Hemoglobin-Membrane Interaction During Sickle Hemoglobin Polymerization

    International Nuclear Information System (INIS)

    Falcon Dieguez, Jose E.; Rodi, Pablo; Lores Guevara, Manuel A.; Gennaro, Ana Maria

    2009-12-01

    An enhanced hemoglobin-membrane association has been previously documented in Sickle Cell Anemia. However, it is not known how this interaction is modified during the hemoglobin S polymerization process. In this work, we use a model of reconstituted erythrocytes from ghost membranes whose cytoskeleton proteins had been previously labeled with the 4-maleimido Tempo spin label, and that were subsequently resealed with hemoglobin S or A solutions. Using EPR spectroscopy, we studied the time dependence of the spectral W/S parameter, indicative of the conformational state of cytoskeleton proteins (mainly spectrin) under spontaneous deoxygenation, with the aim of detecting the eventual effects due to hemoglobin S polymerization. The differences observed in the temporal behaviour of W/S in erythrocytes reconstituted with both hemoglobins were considered as experimental evidence of an increment in hemoglobin S-membrane interaction, as a result of the polymerization process of hemoglobin S under spontaneous deoxygenation. (author)

  9. Seasonal and biological variation of blood concentrations of total cholesterol, dehydroepiandrosterone sulfate, hemoglobin A(1c), IgA, prolactin, and free testosterone in healthy women

    DEFF Research Database (Denmark)

    Garde, A H; Hansen, Åse Marie; Skovgaard, L T

    2000-01-01

    Concentrations of physiological response variables fluctuate over time. The present study describes within-day and seasonal fluctuations for total cholesterol, dehydroepiandrosterone sulfate (DHEA-S), hemoglobin A(1c) (HbA(1c)), IgA, prolactin, and free testosterone in blood, and estimates within......- (CV(i)) and between-subject (CV(g)) CVs for healthy women. In addition, the index of individuality, prediction intervals, and power calculations were derived....

  10. N-glycosylation in sugarcane

    Directory of Open Access Journals (Sweden)

    Maia Ivan G.

    2001-01-01

    Full Text Available The N-linked glycosylation of secretory and membrane proteins is the most complex posttranslational modification known to occur in eukaryotic cells. It has been shown to play critical roles in modulating protein function. Although this important biological process has been extensively studied in mammals, much less is known about this biosynthetic pathway in plants. The enzymes involved in plant N-glycan biosynthesis and processing are still not well defined and the mechanism of their genetic regulation is almost completely unknown. In this paper we describe our first attempt to understand the N-linked glycosylation mechanism in a plant species by using the data generated by the Sugarcane Expressed Sequence Tag (SUCEST project. The SUCEST database was mined for sugarcane gene products potentially involved in the N-glycosylation pathway. This approach has led to the identification and functional assignment of 90 expressed sequence tag (EST clusters sharing significant sequence similarity with the enzymes involved in N-glycan biosynthesis and processing. The ESTs identified were also analyzed to establish their relative abundance.

  11. Utility of noninvasive transcutaneous measurement of postoperative hemoglobin in total joint arthroplasty patients.

    Science.gov (United States)

    Stoesz, Michael; Wood, Kristin; Clark, Wesley; Kwon, Young-Min; Freiberg, Andrew A

    2014-11-01

    This study prospectively evaluated the clinical utility of a noninvasive transcutaneous device for postoperative hemoglobin measurement in 100 total hip and knee arthroplasty patients. A protocol to measure hemoglobin noninvasively, prior to venipuncture, successfully avoided venipuncture in 73% of patients. In the remaining 27 patients, there were a total of 48 venipunctures performed during the postoperative hospitalization period due to reasons including transcutaneous hemoglobin measurement less than or equal to 9 g/dL (19), inability to obtain a transcutaneous hemoglobin measurement (8), clinical signs of anemia (3), and noncompliance with the study protocol (18). Such screening protocols may provide a convenient and cost-effective alternative to routine venipuncture for identifying patients at risk for blood transfusion after elective joint arthroplasty. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Changes of hemoglobin and hematocrit in elderly patients receiving lower joint arthroplasty without allogeneic blood transfusion.

    Science.gov (United States)

    Zhou, Qi; Zhou, Yiqin; Wu, Haishan; Wu, Yuli; Qian, Qirong; Zhao, Hui; Zhu, Yunli; Fu, Peiliang

    2015-01-05

    It has rarely been reported about the changes of hemoglobin (Hb) and hematocrit (Hct) in elderly patients receiving total knee arthroplasty (TKA) or total hip arthroplasty (THA). This study aimed to evaluate the changes of Hb and Hct after TKA or THA in elderly patients, and analyze its relationship with sex and type of arthroplasty. This is a prospective cohort study, including 107 patients receiving TKA or THA without allogeneic blood transfusion. There were 54 males and 53 females, with a mean age of 69.42 years. Levels of Hb and Hct were examined preoperatively and during the 6 months follow-up after operation. Levels of Hb and Hct decreased postoperatively and reached their minimum points on postoperative day 4. Thereafter, Hb and Hct recovered to their preoperative levels within 6-12 weeks. No significant differences in the levels of Hb and Hct were noticed between different sexes. THA patients showed significantly greater drop in Hb and Hct than TKA patients in the first 4 days postoperatively (P < 0.05). Levels of Hb and Hct decreased during the first 4 days after arthroplasty and gradually returned to their normal levels within 6-12 weeks postoperatively. THA may be associated with higher postoperative blood loss than TKA.

  13. Oxygenation level and hemoglobin concentration in experimental tumor estimated by diffuse optical spectroscopy

    Science.gov (United States)

    Orlova, A. G.; Kirillin, M. Yu.; Volovetsky, A. B.; Shilyagina, N. Yu.; Sergeeva, E. A.; Golubiatnikov, G. Yu.; Turchin, I. V.

    2017-07-01

    Using diffuse optical spectroscopy the level of oxygenation and hemoglobin concentration in experimental tumor in comparison with normal muscle tissue of mice have been studied. Subcutaneously growing SKBR-3 was used as a tumor model. Continuous wave fiber probe diffuse optical spectroscopy system was employed. Optical properties extraction approach was based on diffusion approximation. Decreased blood oxygen saturation level and increased total hemoglobin content were demonstrated in the neoplasm. The main reason of such differences between tumor and norm was significant elevation of deoxyhemoglobin concentration in SKBR-3. The method can be useful for diagnosis of tumors as well as for study of blood flow parameters of tumor models with different angiogenic properties.

  14. Long-Term Stored Hemoglobin-Vesicles, a Cellular Type of Hemoglobin-Based Oxygen Carrier, Has Resuscitative Effects Comparable to That for Fresh Red Blood Cells in a Rat Model with Massive Hemorrhage without Post-Transfusion Lung Injury.

    Directory of Open Access Journals (Sweden)

    Masahiro Tokuno

    Full Text Available Hemoglobin-vesicles (HbV, encapsulating highly concentrated human hemoglobin in liposomes, were developed as a substitute for red blood cells (RBC and their safety and efficacy in transfusion therapy has been confirmed in previous studies. Although HbV suspensions are structurally and physicochemically stabile for least 1-year at room temperature, based on in vitro experiments, the issue of whether the use of long-term stored HbV after a massive hemorrhage can be effective in resuscitations without adverse, post-transfusion effects remains to be clarified. We report herein on a comparison of the systemic response and the induction of organ injuries in hemorrhagic shock model rats resuscitated using 1-year-stored HbV, freshly packed RBC (PRBC-0 and by 28-day-stored packed RBC (PRBC-28. The six-hour mortality after resuscitation was not significantly different among the groups. Arterial blood pressure and blood gas parameters revealed that, using HbV, recovery from the shock state was comparable to that when PRBC-0 was used. Although no significant change was observed in serum parameters reflecting liver and kidney injuries at 6 hours after resuscitation among the three resuscitation groups, results based on Evans Blue and protein leakage in bronchoalveolar lavage fluid, the lung wet/dry weight ratio and histopathological findings indicated that HbV as well as PRBC-0 was less predisposed to result in a post-transfusion lung injury than PRBC-28, as evidenced by low levels of myeloperoxidase accumulation and subsequent oxidative damage in the lung. The findings reported herein indicate that 1-year-stored HbV can effectively function as a resuscitative fluid without the induction of post-transfused lung injury and that it is comparable to fresh PRBC, suggesting that HbV is a promising RBC substitute with a long shelf-life.

  15. Nutritional Therapies in Congenital Disorders of Glycosylation (CDG

    Directory of Open Access Journals (Sweden)

    Peter Witters

    2017-11-01

    Full Text Available Congenital disorders of glycosylation (CDG are a group of more than 130 inborn errors of metabolism affecting N-linked, O-linked protein and lipid-linked glycosylation. The phenotype in CDG patients includes frequent liver involvement, especially the disorders belonging to the N-linked protein glycosylation group. There are only a few treatable CDG. Mannose-Phosphate Isomerase (MPI-CDG was the first treatable CDG by high dose mannose supplements. Recently, with the successful use of d-galactose in Phosphoglucomutase 1 (PGM1-CDG, other CDG types have been trialed on galactose and with an increasing number of potential nutritional therapies. Current mini review focuses on therapies in glycosylation disorders affecting liver function and dietary intervention in general in N-linked glycosylation disorders. We also emphasize now the importance of early screening for CDG in patients with mild hepatopathy but also in cholestasis.

  16. Assessment risk of osteoporosis in Chinese people: relationship among body mass index, serum lipid profiles, blood glucose, and bone mineral density

    Directory of Open Access Journals (Sweden)

    Cui RT

    2016-07-01

    Full Text Available Rongtao Cui,1 Lin Zhou,2 Zuohong Li,2 Qing Li,2 Zhiming Qi,2 Junyong Zhang3 1Department of Orthopedic and Trauma Surgery, Surgical Research, Duisburg-Essen University Hospital, Essen, Germany; 2Department of Orthopedics, Dalian Central Hospital, Dalian, 3Department of Gastroenterology, Shandong Provincial Hospital, Jinan, People’s Republic of China Objective: The aim of our study was to investigate the relationship among age, sex, body mass index (BMI, serum lipid profiles, blood glucose (BG, and bone mineral density (BMD, making an assessment of the risk of osteoporosis.Materials and methods: A total of 1,035 male and 3,953 female healthy volunteers (aged 41–95 years were recruited by an open invitation. The basic information, including age, sex, height, weight, waistline, hipline, menstrual cycle, and medical history, were collected by a questionnaire survey and physical examination. Serum lipid profiles, BG, postprandial blood glucose, and glycosylated hemoglobin were obtained after 12 hours fasting. BMD in lumbar spine was measured by dual-energy X-ray absorptiometry scanning.Results: The age-adjusted BMD in females was significantly lower than in males. With aging, greater differences of BMD distribution exist in elderly females than in males (P<0.001, and the fastigium of bone mass loss was in the age range from 51 to 55 in females and from 61 to 65 years in males. After adjustment for sex, there were significant differences in BMD among BMI-stratified groups in both males and females. The subjects with a BMI of <18.5 had a higher incidence of osteoporosis than BMI ≥18.5 in both sexes. BMD in type 2 diabetes mellitus with a BG of >7.0 mmol/L was lower than in people with BG of ≤7.0 mmol/L (P<0.001. People with serum high-density lipoprotein cholesterol levels of ≥1.56 mmol/L had a greater prevalence of osteoporosis compared with high-density lipoprotein cholesterol ≤1.55 mmol/L. Logistic regression with odds ratios showed that

  17. A common signaling pathway is activated in erythroid cells expressing high levels of fetal hemoglobin: a potential role for cAMP-elevating agents in β-globin disorders

    Directory of Open Access Journals (Sweden)

    Ikuta T

    2013-12-01

    Full Text Available Tohru Ikuta,1 Yuichi Kuroyanagi,1 Nadine Odo,1 Siyang Liu21Department of Anesthesiology and Perioperative Medicine, 2Department of Physiology, Medical College of Georgia, Georgia Regents University, Augusta, GA, USABackground: Although erythroid cells prepared from fetal liver, cord blood, or blood from β-thalassemia patients are known to express fetal hemoglobin at high levels, the underlying mechanisms remain elusive. We previously showed that cyclic nucleotides such as cAMP and cGMP induce fetal hemoglobin expression in primary erythroid cells. Here we report that cAMP signaling contributes to high-level fetal hemoglobin expression in erythroid cells prepared from cord blood and β-thalassemia.Methods: The status of the cAMP signaling pathway was investigated using primary erythroid cells prepared from cord blood and the mononuclear cells of patients with β-thalassemia; erythroid cells from adult bone marrow mononuclear cells served as the control.Results: We found that intracellular cAMP levels were higher in erythroid cells from cord blood and β-thalassemia than from adult bone marrow. Protein kinase A activity levels and cAMP-response element binding protein phosphorylation were higher in erythroid cells from cord blood or β-thalassemia than in adult bone marrow progenitors. Mitogen-activated protein kinase pathways, which play a role in fetal hemoglobin expression, were not consistently activated in cord blood or β-thalassemia erythroid cells. When cAMP signaling was activated in adult erythroid cells, fetal hemoglobin was induced at high levels and associated with reduced expression of BCL11A, a silencer of the β-globin gene.Conclusion: These results suggest that activated cAMP signaling may be a common mechanism among erythroid cells with high fetal hemoglobin levels, in part because of downregulation of BCL11A. Activation of the cAMP signaling pathway with cAMP-elevating agents may prove to be an important signaling mechanism to

  18. Glucose Pump Test can be Used to Measure Blood Flow Rate of ...

    African Journals Online (AJOL)

    2018-02-07

    Feb 7, 2018 ... Blood flow rates of AV fistula can be affected by osmotic and oncotic pressures of blood and arterial blood pressures. Sodium, glucose, hemoglobin, and albumin are significant effectors, created osmotic and oncotic pressures [Table 3]. Blood levels of hemoglobin. (Hb), albumin, sodium (Na), and glucose ...

  19. Hemoglobin

    Science.gov (United States)

    1993-03-08

    affinity, which is less at low levels of hemoglobin saturation, increases markedly as fractional saturation increases. Thus, high affinity for 02 at... diphosphoglycerate (2,3-DPG), and carbon dioxide (Co 2). Since they are linked to 02 binding, they are called oxygen-linked effectors. The oxygen...hemoglobin molecule because of the negative charge of the ions. 2,3- Diphosphoglycerate is a molecule formed during the breakdown of sugar in normal human

  20. Structure and stability of human hemoglobin microparticles prepared with a double emulsion technique.

    Science.gov (United States)

    Cedrati, N; Bonneaux, F; Labrude, P; Maincent, P

    1997-09-01

    Hemoglobin solutions can be used as blood substitutes but they present some disadvantages often due to their rapid removal from the bloodstream after injection. A possible way of overcoming this problem is to trap hemoglobin inside particles. This study deals with the preparation, structure and stability of poly(lactic acid) and ethylcellulose microparticles containing human hemoglobin obtained with a double emulsion technique. We investigated the manufacturing process of these particles in order to increase the encapsulation ratio of hemoglobin. For this purpose, some parameters involved in the procedure were optimized, such as hemoglobin concentration and duration of stirring: hemoglobin loading increases with its concentration in the preparation and well-defined stirring time avoids a leakage of hemoglobin. Hemoglobin concentration, surfactant concentration i.e. poly(vinylic alcohol), amounts of polymer and solvent (methylene chloride), duration and speed of stirring. The microparticles were prepared with satisfactory yields (60 to 73%). They were spherical and their mean size was lower than 200 microns. The functional properties of entrapped hemoglobin were studied. The encapsulation did not alter hemoglobin and the oxygen affinity of the hemoglobin remained unmodified (P50 about 13.9 mm Hg in a Bis-Tris buffer pH 7.4 at 37 degrees C). Moreover, only low levels of methemoglobin could be detected (less than 3%). Besides, about 90% of encapsulated hemoglobin could be released from microparticles, with a speed related to the internal structure of the particles. The prepared microparticles were stored during one month at +4 degrees C. No degradation of the particle structure occurred and the functional properties of hemoglobin were preserved. These particles could provide a potential source of oxygen in the field of biotechnologies but any application for a transfusional purpose would first require a drastic reduction in particle size.

  1. Role of Reversible Histidine Coordination in Hydroxylamine Reduction by Plant Hemoglobins (Phytoglobins).

    Science.gov (United States)

    Athwal, Navjot Singh; Alagurajan, Jagannathan; Andreotti, Amy H; Hargrove, Mark S

    2016-10-18

    Reduction of hydroxylamine to ammonium by phytoglobin, a plant hexacoordinate hemoglobin, is much faster than that of other hexacoordinate hemoglobins or pentacoordinate hemoglobins such as myoglobin, leghemoglobin, and red blood cell hemoglobin. The reason for differences in reactivity is not known but could be intermolecular electron transfer between protein molecules in support of the required two-electron reduction, hydroxylamine binding, or active site architecture favoring the reaction. Experiments were conducted with phytoglobins from rice, tomato, and soybean along with human neuroglobin and soybean leghemoglobin that reveal hydroxylamine binding as the rate-limiting step. For hexacoordinate hemoglobins, binding is limited by the dissociation rate constant for the distal histidine, while leghemoglobin is limited by an intrinsically low affinity for hydroxylamine. When the distal histidine is removed from rice phytoglobin, a hydroxylamine-bound intermediate is formed and the reaction rate is diminished, indicating that the distal histidine imidazole side chain is critical for the reaction, albeit not for electron transfer but rather for direct interaction with the substrate. Together, these results demonstrate that phytoglobins are superior at hydroxylamine reduction because they have distal histidine coordination affinity constants near 1, and facile rate constants for binding and dissociation of the histidine side chain. Hexacoordinate hemoglobins such as neuroglobin are limited by tighter histidine coordination that blocks hydroxylamine binding, and pentacoordinate hemoglobins have intrinsically lower hydroxylamine affinities.

  2. Specific features of red blood cell morphology in hemolytic disease neonates undergoing intrauterine intravascular blood transfusion

    Directory of Open Access Journals (Sweden)

    A. V. Ivanova

    2016-01-01

    Full Text Available The paper presents data on the characteristics of red blood cell morphology in infants who have undergone intrauterine intravascular blood transfusion for hemolytic disease of the fetus. The infants are shown to have a reduction in the mean volume of red blood cells and in their mean level of hemoglobin, a decrease in the fraction of fetal hemoglobin and an increase in oxygen tension at half saturation. The above morphological characteristics of red blood cells remain decreased during the neonatal period after exchange transfusion or others, as clinically indicated, which seems to suggest that the compensatory-adaptive mechanisms to regulate hematopoiesis are exhausted and a donor’s red blood cells continue to be predominant.

  3. Accuracy of Blood Loss Measurement during Cesarean Delivery

    OpenAIRE

    Doctorvaladan, Sahar V.; Jelks, Andrea T.; Hsieh, Eric W.; Thurer, Robert L.; Zakowski, Mark I.; Lagrew, David C.

    2017-01-01

    Objective?This study aims to compare the accuracy of visual, quantitative gravimetric, and colorimetric methods used to determine blood loss during cesarean delivery procedures employing a hemoglobin extraction assay as the reference standard. Study Design?In 50 patients having cesarean deliveries blood loss determined by assays of hemoglobin content on surgical sponges and in suction canisters was compared with obstetricians' visual estimates, a quantitative gravimetric method, and the blood...

  4. PERBEDAAN KADAR HEMOGLOBIN METODE SIANMETHEMOGLOBIN DENGAN DAN TANPA SENTRIFUGASI PADA SAMPEL LEUKOSITOSIS

    Directory of Open Access Journals (Sweden)

    wahdah norsiah

    2015-12-01

    Full Text Available Abstract: Examination of hemoglobin levels influenced leukocytosis sianmethemoglobin method that causes increased absorbance measurements of hemoglobin levels increased significantly and the false blood sample that has been diluted with a solution Drabkins in centrifugation at 3000 rpm for 10 minutes and then the absorbance of the supernatant was measured with a photometer at λ 546 nm. This study aimed to analyze the differences in hemoglobin level examination siamethemoglobin method with and without centrifugation at sample leukocytosis. This type of research is observational research laboratory. The study design was cross-sectional study. Samples were taken from the remaining blood samples of patients who have been examined leukositnya number more than 20,000 / uL with Hematology Analyzer (CEL-DYN Ruby February-April 2014, and were divided into 4 groups based on criteria that group 1. leukocyte count of 20,000 / uL-29 999 / mL, group II. 30,000 / uL-39 999 / uL, the group III. 40,000 / uL-49,999 / uL, the group IV. More than 50,000 / uL. The number of samples taken were 20 samples of each group, a total sample of 80 samples. The analysis showed no significant difference in hemoglobin levels siamethemoglobin method with and without centrifugation at sample leukocytosis with a value of p = 0.000 less than 0.05 α. Leukocytosis Turbidity affects the difference in hemoglobin levels with and without centrifugation, the higher the number the greater the difference in leukocyte levels of hemoglobin, hemoglobin level examination results of the study based on the criteria of the number of leukocytes obtained by the difference in hemoglobin levels with and without centrifugation in group I. 0.22 ± 0.07 g / dL, group II 0.40 ± 0.22 g / dL, a group III. 0.44 ± 0.14 g / dL, Group IV. 0.85 ± 0.41 g / dL. The level of hemoglobin in the sample sianmethemoglobin method leukocytosis with more than 20,000 / uL need a centrifuge so that appropriate

  5. Age and metabolic risk factors associated with oxidatively damaged DNA in human peripheral blood mononuclear cells

    DEFF Research Database (Denmark)

    Løhr, Mille; Jensen, Annie; Eriksen, Louise

    2015-01-01

    Aging is associated with oxidative stress-generated damage to DNA and this could be related to metabolic disturbances. This study investigated the association between levels of oxidatively damaged DNA in peripheral blood mononuclear cells (PBMCs) and metabolic risk factors in 1,019 subjects, aged...... 18-93 years. DNA damage was analyzed as strand breaks by the comet assay and levels of formamidopyrimidine (FPG-) and human 8-oxoguanine DNA glycosylase 1 (hOGG1)-sensitive sites There was an association between age and levels of FPG-sensitive sites for women, but not for men. The same tendency......, cholesterol and glycosylated hemoglobin (HbA1c). In the group of men, there were significant positive associations between alcohol intake, HbA1c and FPG-sensitive sites in multivariate analysis. The levels of metabolic risk factors were positively associated with age, yet only few subjects fulfilled all...

  6. Long-Term Single and Joint Effects of Excessive Daytime Napping on the HOMA-IR Index and Glycosylated Hemoglobin: A Prospective Cohort Study.

    Science.gov (United States)

    Li, Xue; Pang, Xiuyu; Zhang, Qiao; Qu, Qiannuo; Hou, Zhigang; Liu, Zhipeng; Lv, Lin; Na, Guanqiong; Zhang, Wei; Sun, Changhao; Li, Ying

    2016-02-01

    This prospective cohort study was conducted to assess the duration of daytime napping and its effect combined with night sleep deprivation on the risk of developing high HOMA-IR (homeostasis model assessment of insulin resistance) index and disadvantageous changes in glycosylated hemoglobin (HbA1c) levels.A total of 5845 diabetes-free subjects (2736 women and 3109 men), 30 to 65 years of age, were targeted for this cohort study since 2008. Multiple adjusted Cox regression models were performed to evaluate the single and joint effects of daytime napping on the risk of an elevated HbA1c level and high HOMA-IR index.After an average of 4.5 years of follow-up, >30 minutes of daytime napping was significantly associated with an increased risk of an elevated HbA1c level (>6.5%) in men and women (all P trend HOMA-IR index in the entire cohort, men, and women were 1.33 (1.10-1.62), 1.46 (1.08-1.98), and 1.47 (1.12-1.91), respectively. The combination of sleep deprivation with no naps or >30 minutes napping and the combination of no sleep deprivation with >30 minutes daytime napping were all associated with an HbA1c level >6.5% (HR = 2.08, 95% CI = 1.24-3.51; HR = 4.00, 95% CI = 2.03-7.90; and HR = 2.05, 95% CI = 1.29-3.27, respectively). No sleep deprivation combined with >30 minutes daytime napping correlated with a high risk of an HbA1c level between 5.7% and 6.4% and high HOMA-IR index (HR = 2.12, 95% CI = 1.48-3.02; and HR = 1.35, 95% CI = 1.10-1.65, respectively).Daytime napping >30 minutes was associated with a high risk of an elevated HbA1c level and high HOMA-IR index. No sleep deprivation combined with napping >30 minutes carries a risk of abnormal glucose metabolism. Sleep deprivation combined with brief daytime napping HOMA-IR index.

  7. Halide-mediated regioselective 6-O-glycosylation of unprotected hexopyranosides with perbenzylated glycosyl bromide donors

    DEFF Research Database (Denmark)

    Niedbal, Dominika Alina; Madsen, Robert

    2016-01-01

    The regio- and stereoselective glycosylation at the 6-position in 2,3,4,6-unprotected hexopyranosides has been investigated with dibutyltin oxide as the directing agent. Perbenzylated hexopyranosyl bromides were employed as the donors and the glycosylations were promoted by tetrabutylammonium...... bromide. The couplings were completely selective for both glucose and galactose donors and acceptors as long as the stannylene acetal of the acceptor was soluble in dichloromethane. This gave rise to a number of 1,2-cis-linked disaccharides in reasonable yields. Mannose donors and acceptors, on the other...

  8. ATP-induced temperature independence of hemoglobin-O2 affinity in heterothermic billfish

    DEFF Research Database (Denmark)

    Weber, Roy E.; Campbell, Kevin L.; Fago, Angela

    2010-01-01

    heterotherms, where it may hamper unloading (e.g. in cold extremities of arctic mammals) or increase the diffusive arterio-venous short-circuiting of O2 (e.g. in counter-current heat exchangers of warm swimming muscles of tuna). We hypothesized analogous blood specializations in heterothermic billfish, whose......The inverse relationship between temperature and hemoglobin-O2 affinity resulting from the exothermic nature of heme oxygenation favors O2 unloading from blood to warm, metabolically active tissues. However, this temperature sensitivity is maladaptive, and commonly countered in regional...... to allosterically modulating hemoglobin-O2 affinity, ATP diminishes its temperature sensitivity, reducing deleterious arterio-venous short-circuiting of oxygen in the cranial billfish heat exchangers. The mechanism underlying this reduction in oxygenation enthalpy differs fundamentally from that in tuna, supporting...

  9. Development of Liposome Encapsulated Hemoglobin (LEH) and Studies of Hemorrhagic Shock by Use of Imaging Studies with Oxygen-15 and Other Radiotracers

    National Research Council Canada - National Science Library

    Phillips, William T; Goins, Beth; Awasthi, Vibhudutta

    2004-01-01

    .... Encapsulating hemoglobin inside a protective lipid membrane, which mimics a red blood cell, has the advantages of decreasing the toxicity of the free hemoglobin, increasing its circulation time...

  10. FRET imaging of hemoglobin concentration in Plasmodium falciparum-infected red cells.

    Directory of Open Access Journals (Sweden)

    Alessandro Esposito

    Full Text Available During its intraerythrocytic asexual reproduction cycle Plasmodium falciparum consumes up to 80% of the host cell hemoglobin, in large excess over its metabolic needs. A model of the homeostasis of falciparum-infected red blood cells suggested an explanation based on the need to reduce the colloid-osmotic pressure within the host cell to prevent its premature lysis. Critical for this hypothesis was that the hemoglobin concentration within the host cell be progressively reduced from the trophozoite stage onwards.The experiments reported here were designed to test this hypothesis by direct measurements of the hemoglobin concentration in live, infected red cells. We developed a novel, non-invasive method to quantify the hemoglobin concentration in single cells, based on Förster resonance energy transfer between hemoglobin molecules and the fluorophore calcein. Fluorescence lifetime imaging allowed the quantitative mapping of the hemoglobin concentration within the cells. The average fluorescence lifetimes of uninfected cohorts was 270+/-30 ps (mean+/-SD; N = 45. In the cytoplasm of infected cells the fluorescence lifetime of calcein ranged from 290+/-20 ps for cells with ring stage parasites to 590+/-13 ps and 1050+/-60 ps for cells with young trophozoites and late stage trophozoite/early schizonts, respectively. This was equivalent to reductions in hemoglobin concentration spanning the range from 7.3 to 2.3 mM, in line with the model predictions. An unexpected ancillary finding was the existence of a microdomain under the host cell membrane with reduced calcein quenching by hemoglobin in cells with mature trophozoite stage parasites.The results support the predictions of the colloid-osmotic hypothesis and provide a better understanding of the homeostasis of malaria-infected red cells. In addition, they revealed the existence of a distinct peripheral microdomain in the host cell with limited access to hemoglobin molecules indicating the

  11. Validation of NIRS in measuring tissue hemoglobin concentration and oxygen saturation on ex vivo and isolated limb models

    Science.gov (United States)

    Xu, Xiaorong; Zhu, Wen; Padival, Vikram; Xia, Mengna; Cheng, Xuefeng; Bush, Robin; Christenson, Linda; Chan, Tim; Doherty, Tim; Iatridis, Angelo

    2003-07-01

    Photonify"s tissue spectrometer uses Near-Infrared Spectroscopy for real-time, noninvasive measurement of hemoglobin concentration and oxygen saturation [SO2] of biological tissues. The technology was validated by a series of ex vivo and animal studies. In the ex vivo experiment, a close loop blood circulation system was built, precisely controlling the oxygen saturation and the hemoglobin concentration of a liquid phantom. Photonify"s tissue spectrometer was placed on the surface of the liquid phantom for real time measurement and compared with a gas analyzer, considered the gold standard to measure oxygen saturation and hemoglobin concentration. In the animal experiment, the right hind limb of each dog accepted onto the study was surgically removed. The limb was kept viable by connecting the femoral vein and artery to a blood-primed extracorporeal circuit. Different concentrations of hemoglobin were obtained by adding designated amount of saline solution into the perfusion circuit. Photonify"s tissue spectrometers measured oxygen saturation and hemoglobin concentration at various locations on the limb and compared with gas analyzer results. The test results demonstrated that Photonify"s tissue spectrometers were able to detect the relative changes in tissue oxygen saturation and hemoglobin concentration with a high linear correlation compared to the gas analyzer

  12. Immediate response of the hemoglobin system of the goldfish, Carassius auratu, to temperature change

    Energy Technology Data Exchange (ETDEWEB)

    Houston, A.H.; Rupert, R.

    1976-10-01

    Goldfish acclimated to 3 and 23/sup 0/C were characterized by two- and three-component hemoglobin systems, respectively. After acclimation to a diurnally cycling temperature regime (approximately 3 to approximately 23/sup 0/C), specimens sampled at approximately 23/sup 0/C and approximately 3/sup 0/C were identical in terms of hemoglobin system complexity with those held at equivalent constant temperatures. Abrupt transfer of fish acclimated at constant 23/sup 0/C to 3/sup 0/C, and vice versa, lead to appearance or disappearance of the minor component, G. l, within 3 h. In vitro cooling and warming of whole blood and hemolyzate samples indicated that hemoglobin system modification occurred under cell-free as well as cell-intact conditions. These observations suggest that previously observed quantitative variations in the hemoglobin systems of thermally acclimated teleosts may represent, in part at least, altered aggregation of preexisting subunits rather than de novo hemoglobin synthesis and raise the possibility that teleostean hemoglobin systems may possess a capacity for rapid, adaptative reorganization after environmental temperature variation.

  13. Glycosylation of the self-recognizing Escherichia coli Ag43 autotransporter protein

    DEFF Research Database (Denmark)

    Sherlock, O.; Dobrindt, U.; Jensen, J.B.

    2006-01-01

    a novel member to this exclusive group, namely, antigen 43 (Ag43), a self-recognizing autotransporter protein. By mass spectrometry Ag43 was demonstrated to be glycosylated by addition of heptose residues at several positions in the passenger domain. Glycosylation of Ag43 by the action of the Aah and Tib......C glycosyltransferases was observed in laboratory strains. Importantly, Ag43 was also found to be glycosylated in a wild-type strain, suggesting that Ag43-glycosylation may be a widespread phenomenon. Glycosylation of Ag43 does not seem to interfere with its self-associating properties. However, the glycosylated form...

  14. Do blood tests cause anemia in hospitalized patients? The effect of diagnostic phlebotomy on hemoglobin and hematocrit levels.

    Science.gov (United States)

    Thavendiranathan, Paaladinesh; Bagai, Akshay; Ebidia, Albert; Detsky, Allan S; Choudhry, Niteesh K

    2005-06-01

    To determine whether phlebotomy contributes to changes in hemoglobin and hematocrit levels in hospitalized general internal medicine patients. Retrospective cohort study. General internal medicine inpatient service at a tertiary care hospital. All adult patients discharged from the Toronto General Hospital's internal medicine service between January 1 and June 30, 2001. A total of 989 hospitalizations were reviewed and 404 hospitalizations were included in our analysis. Mean (SD) hemoglobin and hematocrit changes during hospitalization were 7.9 (12.6) g/L (Phemoglobin and hematocrit were predicted by the volume of phlebotomy, length of hospital stay, admission hemoglobin/hematocrit value, age, Charlson comorbidity index, and admission intravascular volume status. The volume of phlebotomy remained a strong predictor of drop in hemoglobin and hematocrit after adjusting for other predictors using multivariate analysis (Phemoglobin and hematocrit of 7.0 g/L and 1.9%, respectively. Phlebotomy is highly associated with changes in hemoglobin and hematocrit levels for patients admitted to an internal medicine service and can contribute to anemia. This anemia, in turn, may have significant consequences, especially for patients with cardiorespiratory diseases. Knowing the expected changes in hemoglobin and hematocrit due to diagnostic phlebotomy will help guide when to investigate anemia in hospitalized patients.

  15. Digestibility and IgE-Binding of Glycosylated Codfish Parvalbumin

    Science.gov (United States)

    de Jongh, Harmen H. J.; Robles, Carlos López; Nordlee, Julie A.; Lee, Poi-Wah; Baumert, Joseph L.; Hamilton, Robert G.; Taylor, Steve L.; Koppelman, Stef J.

    2013-01-01

    Food-processing conditions may alter the allergenicity of food proteins by different means. In this study, the effect of the glycosylation as a result of thermal treatment on the digestibility and IgE-binding of codfish parvalbumin is investigated. Native and glycosylated parvalbumins were digested with pepsin at various conditions relevant for the gastrointestinal tract. Intact proteins and peptides were analysed for apparent molecular weight and IgE-binding. Glycosylation did not substantially affect the digestion. Although the peptides resulting from digestion were relatively large (3 and 4 kDa), the IgE-binding was strongly diminished. However, the glycosylated parvalbumin had a strong propensity to form dimers and tetramers, and these multimers bound IgE intensely, suggesting stronger IgE-binding than monomeric parvalbumin. We conclude that glycosylation of codfish parvalbumin does not affect the digestibility of parvalbumin and that the peptides resulting from this digestion show low IgE-binding, regardless of glycosylation. Glycosylation of parvalbumin leads to the formation of higher order structures that are more potent IgE binders than native, monomeric parvalbumin. Therefore, food-processing conditions applied to fish allergen can potentially lead to increased allergenicity, even while the protein's digestibility is not affected by such processing. PMID:23878817

  16. Digestibility and IgE-Binding of Glycosylated Codfish Parvalbumin

    Directory of Open Access Journals (Sweden)

    Harmen H. J. de Jongh

    2013-01-01

    Full Text Available Food-processing conditions may alter the allergenicity of food proteins by different means. In this study, the effect of the glycosylation as a result of thermal treatment on the digestibility and IgE-binding of codfish parvalbumin is investigated. Native and glycosylated parvalbumins were digested with pepsin at various conditions relevant for the gastrointestinal tract. Intact proteins and peptides were analysed for apparent molecular weight and IgE-binding. Glycosylation did not substantially affect the digestion. Although the peptides resulting from digestion were relatively large (3 and 4 kDa, the IgE-binding was strongly diminished. However, the glycosylated parvalbumin had a strong propensity to form dimers and tetramers, and these multimers bound IgE intensely, suggesting stronger IgE-binding than monomeric parvalbumin. We conclude that glycosylation of codfish parvalbumin does not affect the digestibility of parvalbumin and that the peptides resulting from this digestion show low IgE-binding, regardless of glycosylation. Glycosylation of parvalbumin leads to the formation of higher order structures that are more potent IgE binders than native, monomeric parvalbumin. Therefore, food-processing conditions applied to fish allergen can potentially lead to increased allergenicity, even while the protein’s digestibility is not affected by such processing.

  17. Functional Analysis of Glycosylation of Zika Virus Envelope Protein

    Directory of Open Access Journals (Sweden)

    Camila R. Fontes-Garfias

    2017-10-01

    Full Text Available Summary: Zika virus (ZIKV infection causes devastating congenital abnormities and Guillain-Barré syndrome. The ZIKV envelope (E protein is responsible for viral entry and represents a major determinant for viral pathogenesis. Like other flaviviruses, the ZIKV E protein is glycosylated at amino acid N154. To study the function of E glycosylation, we generated a recombinant N154Q ZIKV that lacks the E glycosylation and analyzed the mutant virus in mammalian and mosquito hosts. In mouse models, the mutant was attenuated, as evidenced by lower viremia, decreased weight loss, and no mortality; however, knockout of E glycosylation did not significantly affect neurovirulence. Mice immunized with the mutant virus developed a robust neutralizing antibody response and were completely protected from wild-type ZIKV challenge. In mosquitoes, the mutant virus exhibited diminished oral infectivity for the Aedes aegypti vector. Collectively, the results demonstrate that E glycosylation is critical for ZIKV infection of mammalian and mosquito hosts. : Zika virus (ZIKV causes devastating congenital abnormities and Guillain-Barré syndrome. Fontes-Garfias et al. showed that the glycosylation of ZIKV envelope protein plays an important role in infecting mosquito vectors and pathogenesis in mouse. Keywords: Zika virus, glycosylation, flavivirus entry, mosquito transmission, vaccine

  18. Toward stable genetic engineering of human o-glycosylation in plants

    DEFF Research Database (Denmark)

    Yang, Zhang; Bennett, Eric Paul; Jørgensen, Bodil

    2012-01-01

    Glycosylation is the most abundant and complex posttranslational modification to be considered for recombinant production of therapeutic proteins. Mucin-type (N-acetylgalactosamine [GalNAc]-type) O-glycosylation is found in eumetazoan cells but absent in plants and yeast, making these cell types...... an obvious choice for de novo engineering of this O-glycosylation pathway. We previously showed that transient implementation of O-glycosylation capacity in plants requires introduction of the synthesis of the donor substrate UDP-GalNAc and one or more polypeptide GalNAc-transferases for incorporating Gal......NAc residues into proteins. Here, we have stably engineered O-glycosylation capacity in two plant cell systems, soil-grown Arabidopsis (Arabidopsis thaliana) and tobacco (Nicotiana tabacum) Bright Yellow-2 suspension culture cells. Efficient GalNAc O-glycosylation of two stably coexpressed substrate O...

  19. NMR water-proton spin-lattice relaxation time of human red blood cells and red blood cell suspensions

    International Nuclear Information System (INIS)

    Sullivan, S.G.; Rosenthal, J.S.; Winston, A.; Stern, A.

    1988-01-01

    NMR water-proton spin-lattice relaxation times were studied as probes of water structure in human red blood cells and red blood cell suspensions. Normal saline had a relaxation time of about 3000 ms while packed red blood cells had a relaxation time of about 500 ms. The relaxation time of a red blood cell suspension at 50% hematocrit was about 750 ms showing that surface charges and polar groups of the red cell membrane effectively structure extracellular water. Incubation of red cells in hypotonic saline increases relaxation time whereas hypertonic saline decreases relaxation time. Relaxation times varied independently of mean corpuscular volume and mean corpuscular hemoglobin concentration in a sample population. Studies with lysates and resealed membrane ghosts show that hemoglobin is very effective in lowering water-proton relaxation time whereas resealed membrane ghosts in the absence of hemoglobin are less effective than intact red cells. 9 refs.; 3 figs.; 1 table

  20. Comparative and quantitative determination of total hemoglobin concentration in normal and psoriatic patients

    International Nuclear Information System (INIS)

    Mahesar, S.M.; Dahot, M.U.; Khuhawar, M.Y.; Mahesar, H.U.

    2004-01-01

    The cyanmethaemoglobin technique is now recommended as the standard method by International Committee for Standardization in Hematology and British Standards Institution 1966. The hemoglobin is treated with reagent containing potassium ferricyanide, Potassium cyanide and potassium dihydrogen phosphate. The ferricyanide forms methamoglobin which is converted to cyanmethaemoglobin by the cyanide. The average values of hemoglobin, percent determined from the blood samples of normal and psoriatic (n=44) males and (n=35) females were 15.0, 12.7, 13.6 and 11.2 g/100ml. The decrease in hemoglobin concentration could be due to anemia resulting during the cell proliferation epidermis in inflammatory state and Keratolytic disorder which take place in psoriasis. (author)

  1. O-Glycosylation Modulates Proprotein Convertase Activation of Angiopoietin-like Protein 3: POSSIBLE ROLE OF POLYPEPTIDE GalNAc-TRANSFERASE-2 IN REGULATION OF CONCENTRATIONS OF PLASMA LIPIDS

    DEFF Research Database (Denmark)

    Schjoldager, Katrine Ter-Borch Gram; Vester-Christensen, Malene B; Bennett, Eric Paul

    2010-01-01

    immediately C-terminal (TT(226)). We developed an in vivo model system in CHO ldlD cells that was used to show that O-glycosylation in the processing site blocked processing of ANGPTL3. Genome-wide SNP association studies have identified the polypeptide GalNAc-transferase gene, GALNT2, as a candidate gene...... for low HDL and high triglyceride blood levels. We hypothesized that the GalNAc-T2 transferase performed critical O-glycosylation of proteins involved in lipid metabolism. Screening of a panel of proteins known to affect lipid metabolism for potential sites glycosylated by GalNAc-T2 led to identification...

  2. Hemoglobin alpha 2 gene +861 G>A polymorphism in Turkish ...

    African Journals Online (AJOL)

    Dilay Ciglidag Dungul

    carrying individuals with intact beta globin gene. DNA was extracted from peripheral blood sam- ples of seven healthy carrier individuals who have abnormal hemoglobin variants and 16 control individuals from Turkey. Complete coding and intronic sequences of HBA1 and HBA2 genes were amplified by polymerase chain ...

  3. Trans-species Engineering of Glycosylated Therapeutic Proteins

    DEFF Research Database (Denmark)

    Yang, Zhang

    eukaryotes and even prokaryotes. Insect and yeast cells produce O-glycosylation incompatible with use in humans, however recently the yeast Pichia was engineered to perform the first step of human-like O-glycosylation. This review provides an overview of past and current engineering efforts of N...

  4. A low-hemolysis blood aspirator conserves blood during surgery.

    Science.gov (United States)

    Clague, C T; Blackshear, P L

    1995-01-01

    Blood damage caused by traditional vacuum-operated suction tubes, particularly when air is aspirated along with the blood, usually exceeds damage from all other components. In addition to platelet injury, there is a high degree of hemolysis, which leads to high plasma hemoglobin levels and reduces the number of red blood cells available for reinfusion during cases of blood conservation, such as autologous transfusion and cardiac bypass. This work was undertaken to minimize hemolysis, and the accompanying platelet destruction, during aspiration, with the design of a jet-driven aspirator that separates and removes air from blood immediately within the suction tip. The jet-driven aspirator can suction blood at a range of rates from 100 to at least 700 ml/min, separates and removes 80-100% of aspirated air, operates at any orientation, and generates subatmospheric pressures on the order of only 1 inch H2O. In-vitro hemolysis testing showed a significant reduction in average plasma hemoglobin release, from 19.4 mg/dl to 1.8 mg/dl, when air was removed during blood aspiration. In comparative testing with a conventional vacuum suction tube, the jet-driven aspirator showed significantly less hemolysis than the conventional aspirator at comparable rates of air and blood aspiration.

  5. Radioimmunochemical characterization of hemoglobins Lepore and Kenya: unique antigenic determinants located on hybrid hemoglobins

    International Nuclear Information System (INIS)

    Garver, F.A.; Altay, G.; Baker, M.M.; Gravely, M.; Huisman, T.H.J.

    1978-01-01

    Antisera were produced in rabbits to the three known types of Lepore hemoglobins, which contain hybrid delta-β non-α-chains, and to hemoglobin Kenya, which has a hybrid γ-β non-α-chain. By using a sensitive radioimmunoassay technique, the absorbed antisera were shown to contain an antibody population that was specific for the hybrid hemoglobin and did not cross-react with normal hemoglobins. However, with the absorbed Lepore-specific antisera, the three known types of Lepore hemoglobins were antigenically indistinguishable from each other, suggesting that antibodies are not produced to the primary structural differences which define the three non-α-chains of the Lepore hemoglobins. These studies demonstrate that the non-α-subunits of hemoglobins Lepore and Kenya possess unique antigenic determinant sites, evidently resulting from an altered polypeptide conformation

  6. Similarities and Differences in the Glycosylation Mechanisms in Prokaryotes and Eukaryotes

    Directory of Open Access Journals (Sweden)

    Anne Dell

    2010-01-01

    Full Text Available Recent years have witnessed a rapid growth in the number and diversity of prokaryotic proteins shown to carry N- and/or O-glycans, with protein glycosylation now considered as fundamental to the biology of these organisms as it is in eukaryotic systems. This article overviews the major glycosylation pathways that are known to exist in eukarya, bacteria and archaea. These are (i oligosaccharyltransferase (OST-mediated N-glycosylation which is abundant in eukarya and archaea, but is restricted to a limited range of bacteria; (ii stepwise cytoplasmic N-glycosylation that has so far only been confirmed in the bacterial domain; (iii OST-mediated O-glycosylation which appears to be characteristic of bacteria; and (iv stepwise O-glycosylation which is common in eukarya and bacteria. A key aim of the review is to integrate information from the three domains of life in order to highlight commonalities in glycosylation processes. We show how the OST-mediated N- and O-glycosylation pathways share cytoplasmic assembly of lipid-linked oligosaccharides, flipping across the ER/periplasmic/cytoplasmic membranes, and transferring “en bloc” to the protein acceptor. Moreover these hallmarks are mirrored in lipopolysaccharide biosynthesis. Like in eukaryotes, stepwise O-glycosylation occurs on diverse bacterial proteins including flagellins, adhesins, autotransporters and lipoproteins, with O-glycosylation chain extension often coupled with secretory mechanisms.

  7. Patient blood management in elective total hip- and knee-replacement surgery (part 2): a randomized controlled trial on blood salvage as transfusion alternative using a restrictive transfusion policy in patients with a preoperative hemoglobin above 13 g/dl.

    Science.gov (United States)

    So-Osman, Cynthia; Nelissen, Rob G H H; Koopman-van Gemert, Ankie W M M; Kluyver, Ewoud; Pöll, Ruud G; Onstenk, Ron; Van Hilten, Joost A; Jansen-Werkhoven, Thekla M; van den Hout, Wilbert B; Brand, Ronald; Brand, Anneke

    2014-04-01

    Patient blood management is introduced as a new concept that involves the combined use of transfusion alternatives. In elective adult total hip- or knee-replacement surgery patients, the authors conducted a large randomized study on the integrated use of erythropoietin, cell saver, and/or postoperative drain reinfusion devices (DRAIN) to evaluate allogeneic erythrocyte use, while applying a restrictive transfusion threshold. Patients with a preoperative hemoglobin level greater than 13 g/dl were ineligible for erythropoietin and evaluated for the effect of autologous blood reinfusion. Patients were randomized between autologous reinfusion by cell saver or DRAIN or no blood salvage device. Primary outcomes were mean intra- and postoperative erythrocyte use and proportion of transfused patients (transfusion rate). Secondary outcome was cost-effectiveness. In 1,759 evaluated total hip- and knee-replacement surgery patients, the mean erythrocyte use was 0.19 (SD, 0.9) erythrocyte units/patient in the autologous group (n = 1,061) and 0.22 (0.9) erythrocyte units/patient in the control group (n = 698) (P = 0.64). The transfusion rate was 7.7% in the autologous group compared with 8.3% in the control group (P = 0.19). No difference in erythrocyte use was found between cell saver and DRAIN groups. Costs were increased by €298 per patient (95% CI, 76 to 520). In patients with preoperative hemoglobin levels greater than 13 g/dl, autologous intra- and postoperative blood salvage devices were not effective as transfusion alternatives: use of these devices did not reduce erythrocyte use and increased costs.

  8. Glycosylation of the N-terminal potential N-glycosylation sites in the human α1,3-fucosyltransferase V and -VI (hFucTV and -VI)

    DEFF Research Database (Denmark)

    Christensen, Lise Lotte; Bross, Peter Gerd; Ørntoft, Torben Falck

    2000-01-01

    Human alpha1,3-fucosyltransferase V and -VI (hFucTV and -VI) each contain four potential N-glycosylation sites (hFucTV: Asn60, Asn105, Asn167 and Asn198 and hFucTVI: Asn46, Asn91, Asn153 and Asn184). Glycosylation of the two N-terminal potential N-glycosylation sites (hFucTV: Asn60, Asn105 and h......FucTVI: Asn46 and Asn91) have never been studied in detail. In the present study, we have analysed the glycosylation of these potential N-glycosylation sites. Initially, we compared the molecular mass of hFucTV and -VI expressed in COS-7 cells treated with tunicamycin with the mass of the proteins...... in untreated cells. The difference in molecular mass between the proteins in treated and untreated cells corresponded to the presence of at least three N-linked glycans. We then made a series of mutants, in which the asparagine residues in the N-terminal potential N-glycosylation sites were replaced...

  9. Diversity and functions of protein glycosylation in insects.

    Science.gov (United States)

    Walski, Tomasz; De Schutter, Kristof; Van Damme, Els J M; Smagghe, Guy

    2017-04-01

    The majority of proteins is modified with carbohydrate structures. This modification, called glycosylation, was shown to be crucial for protein folding, stability and subcellular location, as well as protein-protein interactions, recognition and signaling. Protein glycosylation is involved in multiple physiological processes, including embryonic development, growth, circadian rhythms, cell attachment as well as maintenance of organ structure, immunity and fertility. Although the general principles of glycosylation are similar among eukaryotic organisms, insects synthesize a distinct repertoire of glycan structures compared to plants and vertebrates. Consequently, a number of unique insect glycans mediate functions specific to this class of invertebrates. For instance, the core α1,3-fucosylation of N-glycans is absent in vertebrates, while in insects this modification is crucial for the development of wings and the nervous system. At present, most of the data on insect glycobiology comes from research in Drosophila. Yet, progressively more information on the glycan structures and the importance of glycosylation in other insects like beetles, caterpillars, aphids and bees is becoming available. This review gives a summary of the current knowledge and recent progress related to glycan diversity and function(s) of protein glycosylation in insects. We focus on N- and O-glycosylation, their synthesis, physiological role(s), as well as the molecular and biochemical basis of these processes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Quantification of extra-cerebral and cerebral hemoglobin concentrations during physical exercise using time-domain near infrared spectroscopy.

    Science.gov (United States)

    Auger, Héloïse; Bherer, Louis; Boucher, Étienne; Hoge, Richard; Lesage, Frédéric; Dehaes, Mathieu

    2016-10-01

    Fitness is known to have beneficial effects on brain anatomy and function. However, the understanding of mechanisms underlying immediate and long-term neurophysiological changes due to exercise is currently incomplete due to the lack of tools to investigate brain function during physical activity. In this study, we used time-domain near infrared spectroscopy (TD-NIRS) to quantify and discriminate extra-cerebral and cerebral hemoglobin concentrations and oxygen saturation ( SO 2 ) in young adults at rest and during incremental intensity exercise. In extra-cerebral tissue, an increase in deoxy-hemoglobin ( HbR ) and a decrease in SO 2 were observed while only cerebral HbR increased at high intensity exercise. Results in extra-cerebral tissue are consistent with thermoregulatory mechanisms to dissipate excess heat through skin blood flow, while cerebral changes are in agreement with cerebral blood flow ( CBF ) redistribution mechanisms to meet oxygen demand in activated regions during exercise. No significant difference was observed in oxy- ( HbO 2 ) and total hemoglobin ( HbT ). In addition HbO 2 , HbR and HbT increased with subject's peak power output (equivalent to the maximum oxygen volume consumption; VO 2 peak) supporting previous observations of increased total mass of red blood cells in trained individuals. Our results also revealed known gender differences with higher hemoglobin in men. Our approach in quantifying both extra-cerebral and cerebral absolute hemoglobin during exercise may help to better interpret past and future continuous-wave NIRS studies that are prone to extra-cerebral contamination and allow a better understanding of acute cerebral changes due to physical exercise.

  11. Imaging the effect of hemoglobin on properties of RBCs using common-path digital holographic microscope

    Science.gov (United States)

    Joglekar, M.; Shah, H.; Trivedi, V.; Mahajan, S.; Chhaniwal, V.; Leitgeb, R.; Javidi, B.; Anand, A.

    2017-07-01

    Adequate supply of oxygen to the body is the most essential requirement. In vertebrate species this function is performed by Hemoglobin contained in red blood cells. The mass concentration of the Hb determines the oxygen carrying capacity of the blood. Thus it becomes necessary to determine its concentration in the blood, which helps in monitoring the health of a person. If the amount of Hb crosses certain range, then it is considered critical. As the Hb constitutes upto 96% of red blood cells dry content, it would be interesting to examine various physical and mechanical parameters of RBCs which depends upon its concentration. Various diseases bring about significant variation in the amount of hemoglobin which may alter certain parameters of the RBC such as surface area, volume, membrane fluctuation etc. The study of the variations of these parameters may be helpful in determining Hb content which will reflect the state of health of a human body leading to disease diagnosis. Any increase or decrease in the amount of Hb will change the density and hence the optical thickness of the RBCs, which affects the cell membrane and thereby changing its mechanical and physical properties. Here we describe the use of lateral shearing digital holographic microscope for quantifying the cell parameters for studying the change in biophysical properties of cells due to variation in hemoglobin concentration.

  12. Erythrocyte 2,3-DPG, PO2 50% and available O2 during the early post-natal fall in hemoglobin in rabbits.

    Science.gov (United States)

    Holter, P H; Halvorsen, S; Refsum, H E

    1982-09-01

    Erythrocyte 2,3-DPG, PO2 50%, whole blood hemoglobin and available O2, and fixed acid Bohr effect were studied during the first 10 days after birth in rapidly growing suckling rabbits. The post-natal fall in hemoglobin concentration was accompanied by a marked rise in erythrocyte 2,3-DPG and a gradual increase in PO2 50%. The rise in PO2 50% was sufficient to keep the available O2 of the blood unchanged throughout the observation period. The observations show that a 2,3-DPG mediated rise in PO2 50% very effectively contributes to maintenance of adequate tissue oxygenation during the post-natal fall in hemoglobin. The rise in 2,3-DPG and and PO2 50% may be due to the ordinary hypoxia-induced shift to the right of the hemoglobin O2 dissociation curve, as observed under other circumstances when blood hemoglobin is rapidly reduced, but the very marked rise in 2,3-DPG and the very low delta PO2 50%/delta 2,3-DPG ratio suggest that the rise may as well be due to hypoxia independent, pre-programmed processes. The fixed acid Bohr effect was essentially the same in newborn and adult rabbits, and was uninfluenced by large variations in 2,3-DPG.

  13. Fc-Glycosylation in Human IgG1 and IgG3 Is Similar for Both Total and Anti-Red-Blood Cell Anti-K Antibodies

    Directory of Open Access Journals (Sweden)

    Myrthe E. Sonneveld

    2018-01-01

    Full Text Available After albumin, immunoglobulin G (IgG are the most abundant proteins in human serum, with IgG1 and IgG3 being the most abundant subclasses directed against protein antigens. The quality of the IgG-Fc-glycosylation has important functional consequences, which have been found to be skewed toward low fucosylation in some antigen-specific immune responses. This increases the affinity to IgG1-Fc-receptor (FcγRIIIa/b and thereby directly affects downstream effector functions and disease severity. To date, antigen-specific IgG-glycosylation have not been analyzed for IgG3. Here, we analyzed 30 pregnant women with anti-K alloantibodies from a prospective screening cohort and compared the type of Fc-tail glycosylation of total serum- and antigen-specific IgG1 and IgG3 using mass spectrometry. Total serum IgG1 and IgG3 Fc-glycoprofiles were highly similar. Fc glycosylation of antigen-specific IgG varied greatly between individuals, but correlated significantly with each other for IgG1 and IgG3, except for bisection. However, although the magnitude of changes in fucosylation and galactosylation were similar for both subclasses, this was not the case for sialylation levels, which were significantly higher for both total and anti-K IgG3. We found that the combination of relative IgG1 and IgG3 Fc-glycosylation levels did not improve the prediction of anti-K mediated disease over IgG1 alone. In conclusion, Fc-glycosylation profiles of serum- and antigen-specific IgG1 and IgG3 are highly similar.

  14. Carbon monoxide reduces near-infrared spectroscopy determined 'total' hemoglobin

    DEFF Research Database (Denmark)

    Niemann, Mads J; Sørensen, Henrik; Siebenmann, Christoph

    2017-01-01

    with CO (1.5 mL kg-1) was added to the circuit. Two NIRS systems (NIRO-200NX and INVOS-5100) assessed ScO2 as the ratio of oxygenated to deoxygenated hemoglobin, while venous blood samples were analyzed for carboxyhemoglobin (COHb). After CO/O2 rebreathing COHb increased to 8.7% (IQR; 7.9-9.4; p = .004...... to normoxia (68.9 ± 6.9%; p hemoglobin decreased (by 19.7 μM (median; IQR 2.8-34.8; p = .016) and 37.3 μM (30.8-46.6; p = .004), respectively) during inhalation of CO/O2 compared...... to inhalation of O2. Therefore, NIRO-200NX determined 'total' hemoglobin (sum of O2Hb and HHb) decreased (by 62.1 μM; 44.5-78.2; p = .001). In conclusion, exposure to CO did not increase MCAVmean, and neither NIRO-200NX nor INVOS-5100 detected a change in ScO2 when CO was added to inhalation of oxygen...

  15. Modification of postnatal hemoglobin level and hematocrit value in the peripheral blood of mice after gamma radiation in utero by MPG (2-mercaptopropionylglycine)

    International Nuclear Information System (INIS)

    Goyal, P.K.; Kumar, S.; Dev, P.K.

    1980-01-01

    Pregnant Swiss albino mice were irradiated with oamma radiation at post-conception days 14.5, 16.25 and 18.25. Hemoglobin level and hematocrit value in the peripheral blood of the male offsprings were found to be below normal during the early postnatal development. The value became normal from 4 week onwards. However these values were found to be significantly elevated in the early postnatal development of the male offsprings of the mice which were administered MPG before irradiation. The possible radioprotective mechanism of MPG is discussed. (M.G.B.)

  16. Feasibility of direct oxygenation of primary-cultured rat hepatocytes using polyethylene glycol-decorated liposome-encapsulated hemoglobin (LEH).

    Science.gov (United States)

    Naruto, Hirosuke; Huang, Hongyun; Nishikawa, Masaki; Kojima, Nobuhiko; Mizuno, Atsushi; Ohta, Katsuji; Sakai, Yasuyuki

    2007-10-01

    We tested the short-term efficacy of liposome-encapsulated hemoglobin (LEH) in cultured rat hepatocytes. Supplementation with LEH (20% of the hemoglobin concentration of blood) did not lower albumin production in static culture, and completely reversed the cell death and deterioration in albumin production caused by an oxygen shortage in 2D flat-plate perfusion bioreactors.

  17. Glycosylation in HIV-1 envelope glycoprotein and its biological implications

    KAUST Repository

    Ho, Yung Shwen

    2013-08-01

    Glycosylation of HIV-1 envelope proteins (Env gp120/gp41) plays a vital role in viral evasion from the host immune response, which occurs through the masking of key neutralization epitopes and the presentation of the Env glycosylation as \\'self\\' to the host immune system. Env glycosylation is generally conserved, yet its continual evolution plays an important role in modulating viral infectivity and Env immunogenicity. Thus, it is believed that Env glycosylation, which is a vital part of the HIV-1 architecture, also controls intra- and inter-clade genetic variations. Discerning intra- and inter-clade glycosylation variations could therefore yield important information for understanding the molecular and biological differences between HIV clades and may assist in effectively designing Env-based immunogens and in clearly understanding HIV vaccines. This review provides an in-depth perspective of various aspects of Env glycosylation in the context of HIV-1 pathogenesis. © 2013 Future Medicine Ltd.

  18. [Non-enzymatic glycosylation of dietary protein in vitro].

    Science.gov (United States)

    Bednykh, B S; Evdokimov, I A; Sokolov, A I

    2015-01-01

    Non-enzymatic glycosylation of proteins, based on discovered by Mayarn reaction of carbohydrate aldehyde group with a free amino group of a protein molecule, is well known to experts in biochemistry of food industry. Generated brown solid in some cases give the product marketable qualities--crackling bread--in others conversely, worsen the product. The biological effects of far-advanced products of non-enzymatic protein glycosylation reaction have not been studied enough, although it was reported previously that they are not split by digestive enzymes and couldn't be absorbed by animals. The objective of this work was to compare the depth of glycosylation of different food proteins of animal and vegetable origin. The objects of the study were proteins of animal (casein, lactoglobulin, albumin) and vegetable (soy isolate, proteins of rice flour, buckwheat, oatmeal) origin, glucose and fructose were selected as glycosylation agents, exposure 15 days at 37 degrees C. Lactoglobulin was glycosylated to a lesser extent among the proteins of animal origin while protein of oatmeal was glycosylated in the least degree among vegetable proteins. Conversely, such proteins as casein and soya isolate protein bound rather large amounts of carbohydrates. Fructose binding with protein was generally higher than the binding of glucose. The only exception was a protein of oatmeal. When of glucose and fructose simultaneously presented in the incubation medium, glucose binding usually increased while binding of fructose, in contrast, reduced. According to the total amount of carbohydrate (mcg), which is able to attach a protein (mg) the studied food proteins located in the following order: albumin (38) > soy protein isolate (23) > casein (15,) > whey protein rice flour protein (6) > protein from buckwheat flour (3) > globulin (2) > protein of oatmeal (0.3). The results obtained are to be used to select the optimal combination of proteins and carbohydrates, in which the glycosylation

  19. Positive Association of Vitamin E Supplementation with Hemoglobin Levels in Mildly Anemic Healthy Pakistani Adults.

    Science.gov (United States)

    Jilani, Tanveer; Azam, Iqbal; Moiz, Bushra; Mehboobali, Naseema; Perwaiz Iqbal, Mohammad

    2015-01-01

    Hemoglobin levels slightly below the lower limit of normal are common in adults in the general population in developing countries. A few human studies have suggested the use of antioxidant vitamins in the correction of mild anemia. The objective of the present study was to investigate the association of vitamin E supplementation in mildly anemic healthy adults with post-supplemental blood hemoglobin levels in the general population of Karachi, Pakistan. In a single-blinded and placebo-controlled randomized trial, 124 mildly anemic subjects from the General Practitioners' Clinics and personnel of the Aga Khan University were randomized into intervention (n = 82) and control (n = 42) group. In the intervention group, each subject was given vitamin E (400 mg) everyday for a period of three months, while control group subjects received a placebo. Eighty six subjects completed the trial. Fasting venous blood was collected at baseline and after three months of supplementation. Hemoglobin levels and serum/plasma concentrations of vitamin E, vitamin B12, folate, ferritin, serum transferrin receptor (sTfR), glucose, total cholesterol, triglycerides, LDL-cholesterol, HDL-cholesterol, creatinine, total-antioxidant-status and erythropoietin were measured and analyzed using repeated measures ANOVA and multiple linear regression. The adjusted regression coefficients (β) and standard error [SE(β)] of the significant predictors of post-supplemental hemoglobin levels were serum concentration of vitamin E (0.983[0.095]), gender (- 0.656[0.244]), sTfR (- 0.06[0.02]) and baseline hemoglobin levels (0.768[0.077]). The study showed a positive association between vitamin E supplementation and enhanced hemoglobin levels in mildly anemic adults.

  20. Functional Analysis of Glycosylation of Zika Virus Envelope Protein.

    Science.gov (United States)

    Fontes-Garfias, Camila R; Shan, Chao; Luo, Huanle; Muruato, Antonio E; Medeiros, Daniele B A; Mays, Elizabeth; Xie, Xuping; Zou, Jing; Roundy, Christopher M; Wakamiya, Maki; Rossi, Shannan L; Wang, Tian; Weaver, Scott C; Shi, Pei-Yong

    2017-10-31

    Zika virus (ZIKV) infection causes devastating congenital abnormities and Guillain-Barré syndrome. The ZIKV envelope (E) protein is responsible for viral entry and represents a major determinant for viral pathogenesis. Like other flaviviruses, the ZIKV E protein is glycosylated at amino acid N154. To study the function of E glycosylation, we generated a recombinant N154Q ZIKV that lacks the E glycosylation and analyzed the mutant virus in mammalian and mosquito hosts. In mouse models, the mutant was attenuated, as evidenced by lower viremia, decreased weight loss, and no mortality; however, knockout of E glycosylation did not significantly affect neurovirulence. Mice immunized with the mutant virus developed a robust neutralizing antibody response and were completely protected from wild-type ZIKV challenge. In mosquitoes, the mutant virus exhibited diminished oral infectivity for the Aedes aegypti vector. Collectively, the results demonstrate that E glycosylation is critical for ZIKV infection of mammalian and mosquito hosts. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  1. Top-Down-Assisted Bottom-Up Method for Homologous Protein Sequencing: Hemoglobin from 33 Bird Species

    Science.gov (United States)

    Song, Yang; Laskay, Ünige A.; Vilcins, Inger-Marie E.; Barbour, Alan G.; Wysocki, Vicki H.

    2015-11-01

    Ticks are vectors for disease transmission because they are indiscriminant in their feeding on multiple vertebrate hosts, transmitting pathogens between their hosts. Identifying the hosts on which ticks have fed is important for disease prevention and intervention. We have previously shown that hemoglobin (Hb) remnants from a host on which a tick fed can be used to reveal the host's identity. For the present research, blood was collected from 33 bird species that are common in the U.S. as hosts for ticks but that have unknown Hb sequences. A top-down-assisted bottom-up mass spectrometry approach with a customized searching database, based on variability in known bird hemoglobin sequences, has been devised to facilitate fast and complete sequencing of hemoglobin from birds with unknown sequences. These hemoglobin sequences will be added to a hemoglobin database and used for tick host identification. The general approach has the potential to sequence any set of homologous proteins completely in a rapid manner.

  2. Alpha chain hemoglobins with electrophoretic mobility similar to that of hemoglobin S in a newborn screening program.

    Science.gov (United States)

    Silva, Marcilene Rezende; Sendin, Shimene Mascarenhas; Araujo, Isabela Couto de Oliveira; Pimentel, Fernanda Silva; Viana, Marcos Borato

    2013-01-01

    To characterize alpha-chain variant hemoglobins with electric mobility similar to that of hemoglobin S in a newborn screening program. β(S) allele and alpha-thalassemia deletions were investigated in 14 children who had undefined hemoglobin at birth and an electrophoretic profile similar to that of hemoglobin S when they were six months old. Gene sequencing and restriction enzymes (DdeI, BsaJI, NlaIV, Bsu36I and TaqI) were used to identify hemoglobins. Clinical and hematological data were obtained from children who attended scheduled medical visits. THE FOLLOWING ALPHA CHAIN VARIANTS WERE FOUND: seven children with hemoglobin Hasharon [alpha2 47(CE5) Asp>His, HbA2:c.142G>C], all associated with alpha-thalassemia, five with hemoglobin Ottawa [alpha1 15(A13) Gly>Arg, HBA1:c.46G>C], one with hemoglobin St Luke's [alpha1 95(G2) Pro>Arg, HBA1:c.287C>G] and another one with hemoglobin Etobicoke [alpha212 84(F5) Ser>Arg, HBA212:c.255C>G]. Two associations with hemoglobin S were found: one with hemoglobin Ottawa and one with hemoglobin St Luke's. The mutation underlying hemoglobin Etobicoke was located in a hybrid α212 allele in one child. There was no evidence of clinically relevant hemoglobins detected in this study. Apparently these are the first cases of hemoglobin Ottawa, St Luke's, Etobicoke and the α212 gene described in Brazil. The hemoglobins detected in this study may lead to false diagnosis of sickle cell trait or sickle cell disease when only isoelectric focusing is used in neonatal screening. Additional tests are necessary for the correct identification of hemoglobin variants.

  3. Detection of Sickle Cell Hemoglobin in Haiti by Genotyping and Hemoglobin Solubility Tests

    Science.gov (United States)

    Carter, Tamar E.; von Fricken, Michael; Romain, Jean R.; Memnon, Gladys; St. Victor, Yves; Schick, Laura; Okech, Bernard A.; Mulligan, Connie J.

    2014-01-01

    Sickle cell disease is a growing global health concern because infants born with the disorder in developing countries are now surviving longer with little access to diagnostic and management options. In Haiti, the current state of sickle cell disease/trait in the population is unclear. To inform future screening efforts in Haiti, we assayed sickle hemoglobin mutations using traditional hemoglobin solubility tests (HST) and add-on techniques, which incorporated spectrophotometry and insoluble hemoglobin separation. We also generated genotype data as a metric for HST performance. We found 19 of 202 individuals screened with HST were positive for sickle hemoglobin, five of whom did not carry the HbS allele. We show that spectrophotometry and insoluble hemoglobin separation add-on techniques could resolve false positives associated with the traditional HST approach, with some limitations. We also discuss the incorporation of insoluble hemoglobin separation observation with HST in suboptimal screening settings like Haiti. PMID:24957539

  4. Frequency of Polycythemia and Other Abnormalities in a Tibetan Herdsmen Population Residing in the Kham Area of Sichuan Province, China.

    Science.gov (United States)

    Zhang, Jian-Bo; Wang, Lin; Chen, Jie; Wang, Zhi-Ying; Cao, Mei; Yie, Shang-Mian; Yang, Hua; Yao, Xiao-Qin; Zeng, Yi; Yang, Yong-Chang; Xie, Chun-Bao; Zhao, Tai-Qiang

    2018-03-01

    The Kham Tibetans are one of several Tibetan ethnic subgroups living in the Kham area of China. Because studies on the high-altitude adaptation of the Kham people are scant, the main aim of this study is to investigate whether the response to hypoxia, especially polycythemia status, in the Kham Tibetans is different from other Tibetan ethnic subgroups. The primary investigation was conducted on 346 native Kham Tibetan adults (268 men and 78 women) from 3 herdsmen villages located in Hongyuan County situated at an altitude of greater than 3600 m. The participants were aged 46.2±14.1 (21-82; mean±SD with range) years. Anthropometric measurements such as weight, height, waist circumference, body mass index, and blood pressure, as well as laboratory blood tests such as glycosylated hemoglobin, hemoglobin, total cholesterol, triglycerides, high-density lipoprotein cholesterol, low-density lipoprotein cholesterol, and uric acid were analyzed. The concentrations of hemoglobin were 171.3±12.9 (66-229) mg·L -1 and 151.4±16.4 (86-190) mg·L -1 in men and women, respectively. The frequency of polycythemia was found to be 25.5 and 21.8% in men and women, respectively. Polycythemia was found to be significantly associated with glycosylated hemoglobin concentrations, hypertension, and hyperuricemia (P=0.002, 0.023, and 0.009, respectively). There is a higher frequency of polycythemia in the Kham Tibetans when compared with reported studies from other Tibetan ethnic subgroups living on the Qinghai-Tibet plateau. Copyright © 2017 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.

  5. Moessbauer studies of hemoglobin in high altitude polycythemia

    International Nuclear Information System (INIS)

    Zhang Xiufang; Shen Linming; Chen Songsen; Ao Zhaohui; Liu Yuanyuan; Gao Naifei; Zheng Yuanming; Shong Liangquan

    1990-01-01

    The Moessbauer spectra have been measured in erythrocytes from normal adults and the patients with high altitude polycythemia (HAPC). The results indicated that two subspectra ''a'' and ''b'', corresponding to oxy- and deoxyhemoglobin respectively, were present in all blood samples, and a third subspectrum ''c'' was found to exist in almost all samples from the patients. The parameters of the third subspectra ''c1'' in most samples from the patients were similar to those of carbon monoxyhemoglobin. The components were considered to be the denatured hemoglobin in RBCs (red blood cells). Together with clinical analysis, a possible mechanism of HAPC has been discussed. (orig.)

  6. Intraoperative blood loss and blood transfusion requirements in patients undergoing orthognathic surgery.

    Science.gov (United States)

    Faverani, Leonardo Perez; Ramalho-Ferreira, Gabriel; Fabris, André Luis Silva; Polo, Tárik Ocon Braga; Poli, Guilherme Henrique Souza; Pastori, Cláudio Maldonado; Marzola, Clóvis; Assunção, Wirley Gonçalves; Garcia-Júnior, Idelmo Rangel

    2014-09-01

    Procedures for the surgical correction of dentofacial deformities may produce important complications, whether due to the potential for vascular injury or to prolonged surgery, both of which may lead to severe blood loss. Fluid replacement with crystalloid, colloid, or even blood products may be required. The aim of this study was to assess blood loss and transfusion requirements in 45 patients (18 males and 27 females; mean age 29.29 years, range 16-52 years) undergoing orthognathic surgery, assigned to one of two groups according to procedure type-rapid maxillary expansion or double-jaw orthognathic surgery. Preoperative hemoglobin and hematocrit levels and intraoperative blood loss were measured. There was a substantial individual variation in pre- and postoperative hemoglobin values (10.3-17 and 8.8-15.4 g/dL, respectively; p surgery and follow meticulous protocols to minimize the risks.

  7. Importance of N-Glycosylation on CD147 for Its Biological Functions

    Science.gov (United States)

    Bai, Yang; Huang, Wan; Ma, Li-Tian; Jiang, Jian-Li; Chen, Zhi-Nan

    2014-01-01

    Glycosylation of glycoproteins is one of many molecular changes that accompany malignant transformation. Post-translational modifications of proteins are closely associated with the adhesion, invasion, and metastasis of tumor cells. CD147, a tumor-associated antigen that is highly expressed on the cell surface of various tumors, is a potential target for cancer diagnosis and therapy. A significant biochemical property of CD147 is its high level of glycosylation. Studies on the structure and function of CD147 glycosylation provide valuable clues to the development of targeted therapies for cancer. Here, we review current understanding of the glycosylation characteristics of CD147 and the glycosyltransferases involved in the biosynthesis of CD147 N-glycans. Finally, we discuss proteins regulating CD147 glycosylation and the biological functions of CD147 glycosylation. PMID:24739808

  8. Importance of N-Glycosylation on CD147 for Its Biological Functions

    Directory of Open Access Journals (Sweden)

    Yang Bai

    2014-04-01

    Full Text Available Glycosylation of glycoproteins is one of many molecular changes that accompany malignant transformation. Post-translational modifications of proteins are closely associated with the adhesion, invasion, and metastasis of tumor cells. CD147, a tumor-associated antigen that is highly expressed on the cell surface of various tumors, is a potential target for cancer diagnosis and therapy. A significant biochemical property of CD147 is its high level of glycosylation. Studies on the structure and function of CD147 glycosylation provide valuable clues to the development of targeted therapies for cancer. Here, we review current understanding of the glycosylation characteristics of CD147 and the glycosyltransferases involved in the biosynthesis of CD147 N-glycans. Finally, we discuss proteins regulating CD147 glycosylation and the biological functions of CD147 glycosylation.

  9. Measuring Post-Partum Haemorrhage in Low-Resource Settings: The Diagnostic Validity of Weighed Blood Loss versus Quantitative Changes in Hemoglobin.

    Directory of Open Access Journals (Sweden)

    Esther Cathyln Atukunda

    Full Text Available Accurate estimation of blood loss is central to prompt diagnosis and management of post-partum hemorrhage (PPH, which remains a leading cause of maternal mortality in low-resource countries. In such settings, blood loss is often estimated visually and subjectively by attending health workers, due to inconsistent availability of laboratory infrastructure. We evaluated the diagnostic accuracy of weighed blood loss (WBL versus changes in peri-partum hemoglobin to detect PPH.Data from this analysis were collected as part of a randomized controlled trial comparing oxytocin with misoprostol for PPH (NCT01866241. Blood samples for complete blood count were drawn on admission and again prior to hospital discharge or before blood transfusion. During delivery, women were placed on drapes and had pre-weighed sanitary towels placed around their perineum. Blood was then drained into a calibrated container and the sanitary towels were added to estimate WBL, where each gram of blood was estimated as a milliliter. Sensitivity, specificity, negative and positive predictive values (PPVs were calculated at various blood volume loss and time combinations, and we fit receiver-operator curves using blood loss at 1, 2, and 24 hours compared to a reference standard of haemoglobin decrease of >10%.A total of 1,140 women were enrolled in the study, of whom 258 (22.6% developed PPH, defined as a haemoglobin drop >10%, and 262 (23.0% had WBL ≥500mL. WBL generally had a poor sensitivity for detection of PPH (85% in high prevalence settings when WBL exceeds 750mL.WBL has poor sensitivity but high specificity compared to laboratory-based methods of PPH diagnosis. These characteristics correspond to a high PPV in areas with high PPH prevalence. Although WBL is not useful for excluding PPH, this low-cost, simple and reproducible method is promising as a reasonable method to identify significant PPH in such settings where quantifiable red cell indices are unavailable.

  10. Alpha chain hemoglobins with electrophoretic mobility similar to that of hemoglobin S in a newborn screening program

    Directory of Open Access Journals (Sweden)

    Marcilene Rezende Silva

    2013-01-01

    Full Text Available OBJECTIVE: To characterize alpha-chain variant hemoglobins with electric mobility similar to that of hemoglobin S in a newborn screening program. METHODS: βS allele and alpha-thalassemia deletions were investigated in 14 children who had undefined hemoglobin at birth and an electrophoretic profile similar to that of hemoglobin S when they were six months old. Gene sequencing and restriction enzymes (DdeI, BsaJI, NlaIV, Bsu36I and TaqI were used to identify hemoglobins. Clinical and hematological data were obtained from children who attended scheduled medical visits. RESULTS: The following alpha chain variants were found: seven children with hemoglobin Hasharon [alpha2 47(CE5 Asp>His, HbA2:c.142G>C], all associated with alpha-thalassemia, five with hemoglobin Ottawa [alpha1 15(A13 Gly>Arg, HBA1:c.46G>C], one with hemoglobin St Luke's [alpha1 95(G2 Pro>Arg, HBA1:c.287C>G] and another one with hemoglobin Etobicoke [alpha212 84(F5 Ser>Arg, HBA212:c.255C>G]. Two associations with hemoglobin S were found: one with hemoglobin Ottawa and one with hemoglobin St Luke's. The mutation underlying hemoglobin Etobicoke was located in a hybrid α212 allele in one child. There was no evidence of clinically relevant hemoglobins detected in this study. CONCLUSION: Apparently these are the first cases of hemoglobin Ottawa, St Luke's, Etobicoke and the α212 gene described in Brazil. The hemoglobins detected in this study may lead to false diagnosis of sickle cell trait or sickle cell disease when only isoelectric focusing is used in neonatal screening. Additional tests are necessary for the correct identification of hemoglobin variants.

  11. Brewer's Yeast Improves Glycemic Indices in Type 2 Diabetes Mellitus.

    Science.gov (United States)

    Hosseinzadeh, Payam; Javanbakht, Mohammad Hassan; Mostafavi, Seyed-Ali; Djalali, Mahmoud; Derakhshanian, Hoda; Hajianfar, Hossein; Bahonar, Ahmad; Djazayery, Abolghassem

    2013-10-01

    Brewer's yeast may have beneficial effects on insulin receptors because of itsglucose tolerance factor in diabetic patients. This study was conducted to investigate the effects of brewer's yeast supplementation on glycemic indices in patients with type 2 diabetes mellitus. In a randomized double-blind controlled clinical trial, 84 adults (21 men and 63 women) aged 46.3 ± 6.1 years old with type 2 diabetes mellitus were recruited and divided randomly into two groups: Supplement group receiving brewer's yeast (six 300mg tablets/day, total 1800 mg) and control group receiving placebo (six 300mg tablets/day) for 12 weeks. Body weight, height, body mass index, food consumption (based on 24h food record), fasting blood sugar (FBS), glycosylated hemoglobin, insulin sensitivity, and insulin resistance were measured before and after the intervention. Data analysis was performed using the Statistical Package for Social Sciences (version 18.0). The changes in FBS, glycosylated hemoglobin, and insulin sensitivity were significantly different between the two groups during the study (respectively P brewer›s yeast besides the usual treatment of diabetes can ameliorate blood glucose variables in type 2 diabetes mellitus.

  12. Effectiveness of a behavior modification program for older people with uncontrolled type 2 diabetes.

    Science.gov (United States)

    Ounnapiruk, Liwan; Wirojratana, Virapun; Meehatchai, Nitaya; Turale, Sue

    2014-06-01

    This quasi-experimental study examined the effectiveness of a behavior modification program for diabetic control in Thai elders with uncontrolled Type 2 Diabetes. Purposive sampling was used to select 30 elders from one community as an intervention group, and 30 from a neighboring community as a control group. The intervention group participated in a program of 12 weeks' duration involving activities related to group counseling, group discussion, and an empowerment process that enhanced appropriate consumption of healthy diet, medication taking, and exercise. Data were collected by interviews using a questionnaire to assess knowledge of diabetes, perceived self-efficacy, and diabetes control behavior, including fasting blood glucose and glycosylated hemoglobin, were examined at the baseline and three months thereafter. At program completion, the intervention group had significantly higher scores of knowledge, self-efficacy, and health behaviors than those in the control group, but blood glucose and glycosylated hemoglobin were not significantly different. Although nurses can use aspects of this program to benefit elders with diabetes who require support and education, further research is required to provide improved health outcomes such as better glycemic control. © 2013 Wiley Publishing Asia Pty Ltd.

  13. Effect of mufa enriched extra virgin olive oil on glycemic status and insulin secretion in diabetic rats

    International Nuclear Information System (INIS)

    Naveed, A.K.; Yousaf, M.J.; Khan, S.; Ahmed, T.; Azeem, Z.

    2013-01-01

    Objective: To evaluate the effect of monounsaturated fatty acid enriched extra virgin olive oil on glycemic status and insulin secretion in diabetic rats. Study Design: Randomized Control Trial. Place and Duration of Study: Department of Biochemistry, Army Medical College, Rawalpindi in collaboration with Centre for Research in Experimental and Applied Medicine, Army Medical College, Rawalpindi and National Institute of Health, Islamabad from March 2010 to June 2011. Material and Methods: Eighty albino rats of Sprague-dawley strain weighing 200-250 g were randomly divided into two groups of 40 rats each. Rats were made diabetic by injecting streptozotocin. Group 1 and Group II were given normal rodent diet and extra virgin olive oil supplemented diet respectively for 06 weeks. At the end of experimentation, fasting blood glucose, glycosylated hemoglobin and insulin were measured. Results: There was significant decrease of fasting blood glucose and glycosylated hemoglobin and significant increase of serum insulin of group II rats when it was compared with group I (control). Conclusion: Monounsaturated fatty acids enriched extra virgin olive oil can significantly improve glycemic status and serum insulin in diabetic rats. (author)

  14. Links between CD147 Function, Glycosylation, and Caveolin-1

    OpenAIRE

    Tang, Wei; Chang, Sharon B.; Hemler, Martin E.

    2004-01-01

    Cell surface CD147 shows remarkable variations in size (31-65 kDa) because of heterogeneous N-glycosylation, with the most highly glycosylated forms functioning to induce matrix metalloproteinase (MMP) production. Here we show that all three CD147 N-glycosylation sites make similar contributions to both high and low glycoforms (HG- and LG-CD147). l-Phytohemagglutinin lectin binding and swainsonine inhibition experiments indicated that HG-CD147 contains N-acetylglucosaminyltransferase V-cataly...

  15. The Chronic and Acute Effects of Exercise Upon Selected Blood Measures.

    Science.gov (United States)

    Roitman, J. L.; Brewer, J. P.

    This study investigated the effects of chronic and acute exercise upon selected blood measures and indices. Nine male cross-country runners were studied. Red blood count, hemoglobin, and hematocrit were measured using standard laboratory techniques; mean corpuscular volume (MCV), mean corpuscular hemoglobin, and mean corpuscular hemoglobin…

  16. Hemoglobin Wayne Trait with Incidental Polycythemia.

    Science.gov (United States)

    Ambelil, Manju; Nguyen, Nghia; Dasgupta, Amitava; Risin, Semyon; Wahed, Amer

    2017-01-01

    Hemoglobinopathies, caused by mutations in the globin genes, are one of the most common inherited disorders. Many of the hemoglobin variants can be identified by hemoglobin analysis using conventional electrophoresis and high performance liquid chromatography; however hemoglobin DNA analysis may be necessary in other cases for confirmation. Here, we report a case of a rare alpha chain hemoglobin variant, hemoglobin Wayne, in a 47-year-old man who presented with secondary polycythemia. Capillary zone electrophoresis and high performance liquid chromatography revealed a significant amount of a hemoglobin variant, which was further confirmed by hemoglobin DNA sequencing as hemoglobin Wayne. Since the patient was not homozygous for hemoglobin Wayne, which is associated with secondary polycythemia, the laboratory diagnosis in this case was critical in ruling out hemoglobinopathy as the etiology of his polycythemia. © 2017 by the Association of Clinical Scientists, Inc.

  17. HEMOGLOBIN AND HEMATOCRITE CHANGES DURING UNCOMPLICATED ANESTHESIA: GENERAL ANESTHESIA AND LOCAL ANESTHESIA

    Directory of Open Access Journals (Sweden)

    KH NAGHIBI

    2002-12-01

    Full Text Available Introduction. Despite of vital role of blood and it"s components as an only curable treatment, it"s transfusion is accompanied by many complications. In the other way, the most important adverse effects of anemia is decrease in oxygen supply to the tissues. Therefore, it is essential to determine those patients need to blood transfusion and exact hemoglobine and hematocrite level which transfusion become necessary. Recent studies show that during general anesthesia due to vasodilation in the level of microcirculation and passage of many red blood cells from microcirculation there is a decreasing in hemoglobine level measured in peripheral veins which named plasma skimming. So, during sampling of hemoglobine and hematocrite from peripheral veins, there is a pseudodecrease in Hb and HCT levels. In this study we want to determine this decrease in Hb and HeT. Methods. Study was done in 182 patients with ASA 1 and 2 undergoing general or local anesthesia for cataract surgery. Duration of nill per os (NPO, preoperotive and intraoperative intravenous fluid administration were simillar in two groups. A sample of blood for preoperative evaluation and another one immediately after operation achevied and compared with each other. Results. There was not significant differences between mean Hb and HCT in two groups preoperotive. But postoperative, there was a significant differences between mean Hb and HCT in general anesthesia vs local anesthesia (P < 0.01. This decrease in Hb and HCT was orderly 0.91 ± 1.14 gr/dl for Hb and 2.862±3.6 percent for Hct. Discussion. In determining of Hb and HCT immediately after general anesthesia, there is some pseudo decrease due to plasma skimming that must be appreciated.

  18. N-linked glycosylation of the immunoglobulin variable region

    NARCIS (Netherlands)

    van de Bovenkamp, Fleur S.; Derksen, Ninotska I. L.; Ooijevaar-de Heer, Pleuni; van Schie, Karin A.; Kruithof, Simone; Berkowska, Magdalena A.; van der Schoot, C. Ellen; Ijspeert, Hanna; van der Burg, Mirjam; Gils, Ann; Hafkenscheid, Lise; Toes, René E. M.; Rombouts, Yoann; Plomp, Rosina; Wuhrer, Manfred; van Ham, S. Marieke; Vidarsson, Gestur; Rispens, Theo

    2018-01-01

    N-glycosylation sites are introduced at positions in which glycans can affect antigen binding as a result of a specific clustering of progenitor glycosylation sites in the germline sequences of variable domain genes. By analyzing multiple human monoclonal and polyclonal (auto)antibody responses, we

  19. Single-cell measurement of red blood cell oxygen affinity

    OpenAIRE

    Caprio, Di; Stokes, Chris; Higgins, John M.; Schonbrun, Ethan

    2015-01-01

    Oxygen is transported throughout the body by hemoglobin in red blood cells. While the oxygen affinity of blood is well understood and is routinely assessed in patients by pulse oximetry, variability at the single-cell level has not been previously measured. In contrast, single-cell measurements of red blood cell volume and hemoglobin concentration are taken millions of times per day by clinical hematology analyzers and are important factors in determining the health of the hematologic system....

  20. The Hemoglobin E Thalassemias

    Science.gov (United States)

    Fucharoen, Suthat; Weatherall, David J.

    2012-01-01

    Hemoglobin E (HbE) is an extremely common structural hemoglobin variant that occurs at high frequencies throughout many Asian countries. It is a β-hemoglobin variant, which is produced at a slightly reduced rate and hence has the phenotype of a mild form of β thalassemia. Its interactions with different forms of α thalassemia result in a wide variety of clinical disorders, whereas its coinheritance with β thalassemia, a condition called hemoglobin E β thalassemia, is by far the most common severe form of β thalassemia in Asia and, globally, comprises approximately 50% of the clinically severe β-thalassemia disorders. PMID:22908199

  1. Evaluation of the Efficiency of the Reticulocyte Hemoglobin Content on Diagnosis for Iron Deficiency Anemia in Chinese Adults

    Directory of Open Access Journals (Sweden)

    Jie Cai

    2017-05-01

    Full Text Available Our aim was to evaluate the cut-off value and efficiency of using reticulocyte hemoglobin content as a marker to diagnose iron deficiency anemia in Chinese adults. 140 adults who needed bone marrow aspiration for diagnosis at the hematology department of the Peking Union Medical College Hospital were enrolled according to the inclusive and exclusive criteria. Venous blood samples were collected to detect complete blood count, including hemoglobin, reticulocyte hemoglobin content, hematocrit, mean cellular volume, corpuscular hemoglobin concentration, hemoglobin content, free erythrocyte protoporphyrin; iron indexes of serum ferritin, serum transferrin receptor, and unsaturated iron-binding capacity; and inflammation markers of C-reactive protein and α-acid glycoprotein. Bone marrow samples were obtained for the bone marrow iron staining, which was used as the standard for the evaluation of iron status in this study. Subjects were divided into three groups according to hemoglobin levels and bone marrow iron staining results: the IDA (iron deficiency anemia group, the NIDA (non-iron deficiency anemia group, and the control group. The differences of the above-mentioned indexes were compared among the three groups and the effect of inflammation was also considered. The cut-off value of reticulocyte hemoglobin content was determined by receiver operation curves. The IDA group (n = 56 had significantly lower reticulocyte hemoglobin content, mean cellular volume, corpuscular hemoglobin concentration, hemoglobin content, and serum ferritin; and higher free erythrocyte protoporphyrin, unsaturated iron-binding capacity, and serum transferrin receptor (p < 0.05 compared with the NIDA group (n = 38 and control group (n = 46. Hematocrit, serum ferritin, and unsaturated iron-binding capacity were significantly affected by inflammation while reticulocyte hemoglobin content and other parameters were not. The cut-off value of reticulocyte hemoglobin content for

  2. Evaluation of the Efficiency of the Reticulocyte Hemoglobin Content on Diagnosis for Iron Deficiency Anemia in Chinese Adults.

    Science.gov (United States)

    Cai, Jie; Wu, Meng; Ren, Jie; Du, Yali; Long, Zhangbiao; Li, Guoxun; Han, Bing; Yang, Lichen

    2017-05-02

    Our aim was to evaluate the cut-off value and efficiency of using reticulocyte hemoglobin content as a marker to diagnose iron deficiency anemia in Chinese adults. 140 adults who needed bone marrow aspiration for diagnosis at the hematology department of the Peking Union Medical College Hospital were enrolled according to the inclusive and exclusive criteria. Venous blood samples were collected to detect complete blood count, including hemoglobin, reticulocyte hemoglobin content, hematocrit, mean cellular volume, corpuscular hemoglobin concentration, hemoglobin content, free erythrocyte protoporphyrin; iron indexes of serum ferritin, serum transferrin receptor, and unsaturated iron-binding capacity; and inflammation markers of C-reactive protein and α-acid glycoprotein. Bone marrow samples were obtained for the bone marrow iron staining, which was used as the standard for the evaluation of iron status in this study. Subjects were divided into three groups according to hemoglobin levels and bone marrow iron staining results: the IDA (iron deficiency anemia) group, the NIDA (non-iron deficiency anemia) group, and the control group. The differences of the above-mentioned indexes were compared among the three groups and the effect of inflammation was also considered. The cut-off value of reticulocyte hemoglobin content was determined by receiver operation curves. The IDA group ( n = 56) had significantly lower reticulocyte hemoglobin content, mean cellular volume, corpuscular hemoglobin concentration, hemoglobin content, and serum ferritin; and higher free erythrocyte protoporphyrin, unsaturated iron-binding capacity, and serum transferrin receptor ( p iron-binding capacity were significantly affected by inflammation while reticulocyte hemoglobin content and other parameters were not. The cut-off value of reticulocyte hemoglobin content for diagnosing iron deficiency anemia was 27.2 pg, with a sensitivity of 87.5% and a specificity of 92.9%. The cut-off values for

  3. Prediction of hemoglobin levels in whole blood donors: how to model donation history

    NARCIS (Netherlands)

    Baart, A.M.; Vergouwe, Y.; Atsma, F.; Moons, K.G.; Kort, W.L. de

    2014-01-01

    BACKGROUND: Recently, prediction models for hemoglobin (Hb) deferral risk have been developed. These models consider the previous Hb level plus change in Hb. Here, we investigated if the performance of models could be improved by considering more information on Hb level history. STUDY DESIGN AND

  4. Novel idea to monitor and measure blood hemoglobin noninvasively ...

    African Journals Online (AJOL)

    Measuring blood hematocrit noninvasively is reviewed in this paper. Although there is an inclination to measure the hematocrit by determining the bioelectrical impedance of the blood, in vitro experimental methods still remain practically inapplicable. The blood sample size is determined when blood samples are examined.

  5. Serum-free Erythroid Differentiation for Efficient Genetic Modification and High-Level Adult Hemoglobin Production.

    Science.gov (United States)

    Uchida, Naoya; Demirci, Selami; Haro-Mora, Juan J; Fujita, Atsushi; Raines, Lydia N; Hsieh, Matthew M; Tisdale, John F

    2018-06-15

    In vitro erythroid differentiation from primary human cells is valuable to develop genetic strategies for hemoglobin disorders. However, current erythroid differentiation methods are encumbered by modest transduction rates and high baseline fetal hemoglobin production. In this study, we sought to improve both genetic modification and hemoglobin production among human erythroid cells in vitro . To model therapeutic strategies, we transduced human CD34 + cells and peripheral blood mononuclear cells (PBMCs) with lentiviral vectors and compared erythropoietin-based erythroid differentiation using fetal-bovine-serum-containing media and serum-free media. We observed more efficient transduction (85%-93%) in serum-free media than serum-containing media (20%-69%), whereas the addition of knockout serum replacement (KSR) was required for serum-free media to promote efficient erythroid differentiation (96%). High-level adult hemoglobin production detectable by electrophoresis was achieved using serum-free media similar to serum-containing media. Importantly, low fetal hemoglobin production was observed in the optimized serum-free media. Using KSR-containing, serum-free erythroid differentiation media, therapeutic adult hemoglobin production was detected at protein levels with β-globin lentiviral transduction in both CD34 + cells and PBMCs from sickle cell disease subjects. Our in vitro erythroid differentiation system provides a practical evaluation platform for adult hemoglobin production among human erythroid cells following genetic manipulation.

  6. Further investigations on the influence of ultraviolet irradiation on blood corpuscles hemoglobin content and differential leucocyte count in the chicken

    International Nuclear Information System (INIS)

    Bolukbasi, F.

    1978-01-01

    The influence of ultraviolet irradiation, applied for one hour, with a relatively high enerqy output of 95.5x10 3 erg. cm -2 . sn -1 , on some biological parameters of chicken's blood was determined. At the 24th hour after irradiation erythrocyte count, hemoglobin content and percentages of lymphocytes, monocytes, eosinophils and basophils were decreased, but total leucocyte, thrombocyte counts and percentage of pseudoeosinophils were increased, significantly (P< 0,01). No significant changes were obtained in all parameters, at the 24th hour after a second irradiation. There were also found no differences between the values obtained at 24th hour after the second, and at 48th hour after the single irradiation, but all these values had a tendency taward the initial determinations

  7. [The role of protein glycosylation in immune system].

    Science.gov (United States)

    Ząbczyńska, Marta; Pocheć, Ewa

    2015-01-01

    Glycosylation is one of the most frequent post-translational modifications of proteins. The majority of cell surface and secreted proteins involved in immune response is glycosylated. The structural diversity of glycans depends on monosaccharide composition, type of glycosidic linkage and branching. These structural modifications determine a great variability of glycoproteins. The oligosaccharide components of proteins are regulated mostly by expression of glycosyltransferases and glycosidases and many environmental factors. Glycosylation influences the function of all immune cells. Glycans play a crucial role in intercellular contacts and leukocytes migration. These interactions are important in activation and proliferation of leukocytes and during immune response. The key immune proteins, such as TCR, MHC, TLR and antibodies are glycosylated. Sugars on the surface of pathogens and self-surface glycoproteins are recognized by special carbohydrate binding proteins called lectins. Changes of glycan structure are common in many pathological processes occurring in immune system, therefore they are used as molecular markers of different diseases.

  8. Hydrophobic Man-1-P derivatives correct abnormal glycosylation in Type I congenital disorder of glycosylation fibroblasts.

    Science.gov (United States)

    Eklund, Erik A; Merbouh, Nabyl; Ichikawa, Mie; Nishikawa, Atsushi; Clima, Jessica M; Dorman, James A; Norberg, Thomas; Freeze, Hudson H

    2005-11-01

    Patients with Type I congenital disorders of glycosylation (CDG-I) make incomplete lipid-linked oligosaccharides (LLO). These glycans are poorly transferred to proteins resulting in unoccupied glycosylation sequons. Mutations in phosphomannomutase (PMM2) cause CDG-Ia by reducing the activity of PMM, which converts mannose (Man)-6-P to Man-1-P before formation of GDP-Man. These patients have reduced Man-1-P and GDP-Man. To replenish intracellular Man-1-P pools in CDG-Ia cells, we synthesized two hydrophobic, membrane permeable acylated versions of Man-1-P and determined their ability to normalize LLO size and N-glycosylation in CDG-Ia fibroblasts. Both compounds, compound I (diacetoxymethyl 2,3,4,6-tetra-O-acetyl-alpha-D-mannopyranosyl phosphate) (C-I) and compound II (diacetoxymethyl 2,3,4,6-tetra-O-ethyloxycarbonyl-alpha-D-mannopyranosyl phosphate) (C-II), contain two acetoxymethyl (CH2OAc) groups O-linked to phosphorous. C-I contains acetyl esters and C-II contains ethylcarbonate (CO2Et) esters on the Man residue. Both C-I and C-II normalized truncated LLO, but C-II was about 2-fold more efficient than C-I. C-II replenished the GDP-Man pool in CDG-Ia cells and was more efficiently incorporated into glycoproteins than exogenous Man at low concentrations (25-75 mM). In a glycosylation assay of DNaseI in CDG-Ia cells, C-II restored glycosylation to control cell levels. C-II also corrected impaired LLO biosynthesis in cells from a Dolichol (Dol)-P-Man deficient patient (CDG-Ie) and partially corrected LLO in cells from an ALG12 mannosyltransferase-deficient patient (CDG-Ig), whereas cells from an ALG3-deficient patient (CDG-Id) and from an MPDU1-deficient patient (CDG-If) were not corrected. These results validate the general concept of using pro-Man-1-P substrates as potential therapeutics for CDG-I patients.

  9. ECM Proteins Glycosylation and Relation to Diabetes

    Science.gov (United States)

    Pernodet, Nadine; Bloomberg, Ayla; Sood, Vandana; Slutsky, Lenny; Ge, Shouren; Clark, Richard; Rafailovich, Miriam

    2004-03-01

    The chemical modification and crosslinking of proteins by sugar glycosylation contribute to the aging of tissue proteins, and acceleration of this reaction during hyperglycemia is implicated in the pathogenesis of diabetic complications, such as disorder of the wound healing. Advanced glycation endproducts (AGEs) formation and protein crosslinking are irreversible processes that alter the structural and functional properties of proteins, lipid components and nucleic acids. And the mechanism, by which it happens, is not clear. Fibrinogen and fibronectin are plasma proteins, which play a major role in human wound healing. Fibrinogen converts to an insoluble fibrin "gel" following a cut, which eventually forms a clot to prevent blood loss, to direct cell adhesion and migration for forming scars. Fibronectin is a critical protein for cell adhesion and migration in wound healing. The effects of glucose on the binding of these plasma proteins from the extra cellular matrix (ECM) were followed at different concentrations by atomic force microscopy and lateral force modulation to measure the mechanical response of the samples. Glucose solutions (1, 2, and 3mg/mL) were incubated with the protein (100 mg/ml) and silicon (Si) substrates spun with sulfonated polystyrene (SPS) 28% for five days. Data showed that not only the organization of the protein on the surface was affected but also its mechanical properties. At 3 mg/mL glucose, Fn fibers were observed to be harder than those of the control, in good agreement with our hypothesis that glycosylation hardens tissues by crosslinking of proteins in the ECM and might cause fibers to break more easily.

  10. Plasma free hemoglobin and microcirculatory response to fresh or old blood transfusions in sepsis.

    Directory of Open Access Journals (Sweden)

    Elisa Damiani

    Full Text Available Free hemoglobin (fHb may induce vasoconstriction by scavenging nitric oxide. It may increase in older blood units due to storage lesions. This study evaluated whether old red blood cell transfusion increases plasma fHb in sepsis and how the microvascular response may be affected.This is a secondary analysis of a randomized study. Twenty adult septic patients received either fresh or old (15 days storage, respectively RBC transfusions. fHb was measured in RBC units and in the plasma before and 1 hour after transfusion. Simultaneously, the sublingual microcirculation was assessed with sidestream-dark field imaging. The perfused boundary region was calculated as an index of glycocalyx damage. Tissue oxygen saturation (StO2 and Hb index (THI were measured with near-infrared spectroscopy and a vascular occlusion test was performed.Similar fHb levels were found in the supernatant of fresh and old RBC units. Despite this, plasma fHb increased in the old RBC group after transfusion (from 0.125 [0.098-0.219] mg/mL to 0.238 [0.163-0.369] mg/mL, p = 0.006. The sublingual microcirculation was unaltered in both groups, while THI increased. The change in plasma fHb was inversely correlated with the changes in total vessel density (r = -0.57 [95% confidence interval -0.82, -0.16], p = 0.008, De Backer score (r = -0.63 [95% confidence interval -0.84, -0.25], p = 0.003 and THI (r = -0.72 [95% confidence interval -0.88, -0.39], p = 0.0003.Old RBC transfusion was associated with an increase in plasma fHb in septic patients. Increasing plasma fHb levels were associated with decreased microvascular density.ClinicalTrials.gov NCT01584999.

  11. Evaluation of a next generation direct whole blood enzymatic assay for hemoglobin A1c on the ARCHITECT c8000 chemistry system.

    Science.gov (United States)

    Teodoro-Morrison, Tracy; Janssen, Marcel J W; Mols, Jasper; Hendrickx, Ben H E; Velmans, Mathieu H; Lotz, Johannes; Lackner, Karl; Lennartz, Lieselotte; Armbruster, David; Maine, Gregory; Yip, Paul M

    2015-01-01

    The utility of HbA1c for the diagnosis of type 2 diabetes requires an accurate, precise and robust test measurement system. Currently, immunoassay and HPLC are the most popular methods for HbA1c quantification, noting however the limitations associated with some platforms, such as imprecision or interference from common hemoglobin variants. Abbott Diagnostics has introduced a fully automated direct enzymatic method for the quantification of HbA1c from whole blood on the ARCHITECT chemistry system. Here we completed a method evaluation of the ARCHITECT HbA1c enzymatic assay for imprecision, accuracy, method comparison, interference from hemoglobin variants and specimen stability. This was completed at three independent clinical laboratories in North America and Europe. The total imprecision ranged from 0.5% to 2.2% CV with low and high level control materials. Around the diagnostic cut-off of 48 mmol/mol, the total imprecision was 0.6% CV. Mean bias using reference samples from IFCC and CAP ranged from -1.1 to 1.0 mmol/mol. The enzymatic assay also showed excellent agreement with HPLC methods, with slopes of 1.01 and correlation coefficients ranging from 0.984 to 0.996 compared to Menarini Adams HA-8160, Bio-Rad Variant II and Variant II Turbo instruments. Finally, no significant effect was observed for erythrocyte sedimentation or interference from common hemoglobin variants in patient samples containing heterozygous HbS, HbC, HbD, HbE, and up to 10% HbF. The ARCHITECT enzymatic assay for HbA1c is a robust and fully automated method that meets the performance requirements to support the diagnosis of type 2 diabetes.

  12. Blood indicators of seasonal metabolic patterns in captive adult gray wolves

    Science.gov (United States)

    Seal, U.S.; Mech, L.D.

    1983-01-01

    Blood samples and physical data were collected weekly from a colony of gray wolves (Canis lupus) maintained under natural weather arid light conditions. Sampling over 33 continuous months indicated that hemoglobin, hematocrit, red blood cells, mean corpuscular hemoglobin concentration (MCHC), and thyroxine exhibited consistent circannual patterns of variation in both males and females. Hemoglobin levels peaked at 15-16 g/dl in January in females and at 16-17 g/dl in February in males, and were lowest in August at 10.5-11.5 g/dl (P patterns of hematocrit, red blood cells, and MCHC were similarly timed. Females also had a cyclic pattern of white blood cell counts and body weight; their weight peaked in early February and was lowest in August (P pattern.

  13. The Effects of Blood Transfusion on Delirium Incidence.

    Science.gov (United States)

    van der Zanden, Vera; Beishuizen, Sara J; Scholtens, Rikie M; de Jonghe, Annemarieke; de Rooij, Sophia E; van Munster, Barbara C

    2016-08-01

    Both anemia and blood transfusion could be precipitating factors for delirium; hence in postoperative patients with anemia at high risk for delirium, it is controversial whether transfusion is the best option. The aim of this study is to investigate the association of anemia and delirium and the role of blood transfusion within the multicomponent prevention strategy of delirium. We conducted a substudy of a multicenter randomized controlled trial. Four hundred fifteen patients aged 65 to 102 years old admitted for hip fracture surgery were enrolled. Delirium was assessed daily using criteria of the Diagnostic and Statistical Manual of Mental Disorders, fourth edition. Data on hemoglobin values and transfusion were collected from the electronic medical records. One hundred fifteen (32.5%) patients experienced delirium during hospitalization, 238 (57.5%) had a hemoglobin level ≤ 6.0 mmol/L (9.7 g/dL) at any time during hospitalization, and 140 (33.7%) received a blood transfusion. Anemia (a hemoglobin level ≤ 6.0 mmol/L [9.7 g/dL]) was associated with delirium (odds ratio, 1.81; 95% confidence interval, 1.15-2.86). Blood transfusion was a protective factor for delirium in patients with the lowest measured hemoglobin level ≤ 6.0 mmol/L (9.7 g/dL) (odds ratio, 0.26; 95% confidence interval, 0.10-0.70). Low hemoglobin level is associated with delirium, and receiving a blood transfusion is associated with a lower delirium incidence. It would be interesting to investigate the effect of blood transfusion as part of the multicomponent treatment of delirium in patients with anemia. Copyright © 2016 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  14. Phylogeny of Echinoderm Hemoglobins.

    Directory of Open Access Journals (Sweden)

    Ana B Christensen

    Full Text Available Recent genomic information has revealed that neuroglobin and cytoglobin are the two principal lineages of vertebrate hemoglobins, with the latter encompassing the familiar myoglobin and α-globin/β-globin tetramer hemoglobin, and several minor groups. In contrast, very little is known about hemoglobins in echinoderms, a phylum of exclusively marine organisms closely related to vertebrates, beyond the presence of coelomic hemoglobins in sea cucumbers and brittle stars. We identified about 50 hemoglobins in sea urchin, starfish and sea cucumber genomes and transcriptomes, and used Bayesian inference to carry out a molecular phylogenetic analysis of their relationship to vertebrate sequences, specifically, to assess the hypothesis that the neuroglobin and cytoglobin lineages are also present in echinoderms.The genome of the sea urchin Strongylocentrotus purpuratus encodes several hemoglobins, including a unique chimeric 14-domain globin, 2 androglobin isoforms and a unique single androglobin domain protein. Other strongylocentrotid genomes appear to have similar repertoires of globin genes. We carried out molecular phylogenetic analyses of 52 hemoglobins identified in sea urchin, brittle star and sea cucumber genomes and transcriptomes, using different multiple sequence alignment methods coupled with Bayesian and maximum likelihood approaches. The results demonstrate that there are two major globin lineages in echinoderms, which are related to the vertebrate neuroglobin and cytoglobin lineages. Furthermore, the brittle star and sea cucumber coelomic hemoglobins appear to have evolved independently from the cytoglobin lineage, similar to the evolution of erythroid oxygen binding globins in cyclostomes and vertebrates.The presence of echinoderm globins related to the vertebrate neuroglobin and cytoglobin lineages suggests that the split between neuroglobins and cytoglobins occurred in the deuterostome ancestor shared by echinoderms and vertebrates.

  15. Prion propagation in cells expressing PrP glycosylation mutants.

    Science.gov (United States)

    Salamat, Muhammad K; Dron, Michel; Chapuis, Jérôme; Langevin, Christelle; Laude, Hubert

    2011-04-01

    Infection by prions involves conversion of a host-encoded cell surface protein (PrP(C)) to a disease-related isoform (PrP(Sc)). PrP(C) carries two glycosylation sites variably occupied by complex N-glycans, which have been suggested by previous studies to influence the susceptibility to these diseases and to determine characteristics of prion strains. We used the Rov cell system, which is susceptible to sheep prions, to generate a series of PrP(C) glycosylation mutants with mutations at one or both attachment sites. We examined their subcellular trafficking and ability to convert into PrP(Sc) and to sustain stable prion propagation in the absence of wild-type PrP. The susceptibility to infection of mutants monoglycosylated at either site differed dramatically depending on the amino acid substitution. Aglycosylated double mutants showed overaccumulation in the Golgi compartment and failed to be infected. Introduction of an ectopic glycosylation site near the N terminus fully restored cell surface expression of PrP but not convertibility into PrP(Sc), while PrP(C) with three glycosylation sites conferred cell permissiveness to infection similarly to the wild type. In contrast, predominantly aglycosylated molecules with nonmutated N-glycosylation sequons, produced in cells expressing glycosylphosphatidylinositol-anchorless PrP(C), were able to form infectious PrP(Sc). Together our findings suggest that glycosylation is important for efficient trafficking of anchored PrP to the cell surface and sustained prion propagation. However, properly trafficked glycosylation mutants were not necessarily prone to conversion, thus making it difficult in such studies to discern whether the amino acid changes or glycan chain removal most influences the permissiveness to prion infection.

  16. Unusual glycosylation of proteins: Beyond the universal sequon and other amino acids.

    Science.gov (United States)

    Dutta, Devawati; Mandal, Chhabinath; Mandal, Chitra

    2017-12-01

    Glycosylation of proteins is the most common, multifaceted co- and post-translational modification responsible for many biological processes and cellular functions. Significant alterations and aberrations of these processes are related to various pathological conditions, and often turn out to be disease biomarkers. Conventional N-glycosylation occurs through the recognition of the consensus sequon, asparagine (Asn)-X-serine (Ser)/threonine (Thr), where X is any amino acid except for proline, with N-acetylglucosamine (GlcNAc) as the first glycosidic linkage. Usually, O-glycosylation adds a glycan to the hydroxyl group of Ser or Thr beginning with N-acetylgalactosamine (GalNAc). Protein glycosylation is further governed by additional diversifications in sequon and structure, which are yet to be fully explored. This review mainly focuses on the occurrence of N-glycosylation in non-consensus motifs, where Ser/Thr at the +2 position is substituted by other amino acids. Additionally, N-glycosylation is also observed in other amide/amine group-containing amino acids. Similarly, O-glycosylation occurs at hydroxyl group-containing amino acids other than serine/threonine. The neighbouring amino acids and local structural features around the potential glycosylation site also play a significant role in determining the extent of glycosylation. All of these phenomena that yield glycosylation at the atypical sites are reported in a variety of biological systems, including different pathological conditions. Therefore, the discovery of more novel sequence patterns for N- and O-glycosylation may help in understanding the functions of complex biological processes and cellular functions. Taken together, all these information provided in this review would be helpful for the biological readers. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Hemoglobin adducts in workers exposed to 1,6-hexamethylene diisocyanate.

    Science.gov (United States)

    Flack, Sheila L; Fent, Kenneth W; Gaines, Linda G T; Thomasen, Jennifer M; Whittaker, Stephen G; Ball, Louise M; Nylander-French, Leena A

    2011-05-01

    We investigated the utility of 1,6-hexamethylene diamine (HDA) hemoglobin adducts as biomarkers of exposure to 1,6-hexamethylene diisocyanate (HDI) monomer. Blood samples from 15 spray painters applying HDI-containing paint were analyzed for hemoglobin HDA (HDA-Hb) and N-acetyl-1,6-hexamethylene diamine (monoacetyl-HDA-Hb) by GC-MS. HDA-Hb was detected in the majority of workers (≤1.2-37 ng/g Hb), whereas monoacetyl-HDA-Hb was detected in one worker (0.06 ng/g Hb). The stronger, positive association between HDA-Hb and cumulative HDI exposure (r(2) = 0.3, p HDA-Hb adducts. This association demonstrates the suitability of HDA-Hb adducts for further validation as a biomarker of HDI exposure.

  18. Effect of Graded Levels of Soybean Hull on Blood, Carcass and ...

    African Journals Online (AJOL)

    Each treatment was replicated 3 times with 2 pigs per replicate placed on concrete-floored pens. ... Results showed that pigs fed the control diets had comparable (p>0.05) packed cell volume (PCV), hemoglobin concentration (Hb), red blood cell counts (RBC), white blood cell counts (WBC), mean corpuscular hemoglobin ...

  19. Protective effect of bioflavonoid myricetin enhances carbohydrate metabolic enzymes and insulin signaling molecules in streptozotocin–cadmium induced diabetic nephrotoxic rats

    Energy Technology Data Exchange (ETDEWEB)

    Kandasamy, Neelamegam; Ashokkumar, Natarajan, E-mail: npashokkumar1@gmail.com

    2014-09-01

    Diabetic nephropathy is the kidney disease that occurs as a result of diabetes. The present study was aimed to evaluate the therapeutic potential of myricetin by assaying the activities of key enzymes of carbohydrate metabolism, insulin signaling molecules and renal function markers in streptozotocin (STZ)–cadmium (Cd) induced diabetic nephrotoxic rats. After myricetin treatment schedule, blood and tissue samples were collected to determine plasma glucose, insulin, hemoglobin, glycosylated hemoglobin and renal function markers, carbohydrate metabolic enzymes in the liver and insulin signaling molecules in the pancreas and skeletal muscle. A significant increase of plasma glucose, glycosylated hemoglobin, urea, uric acid, creatinine, blood urea nitrogen (BUN), urinary albumin, glycogen phosphorylase, glucose-6-phosphatase, and fructose-1,6-bisphosphatase and a significant decrease of plasma insulin, hemoglobin, hexokinase, glucose-6-phosphate dehydrogenase, glycogen and glycogen synthase with insulin signaling molecule expression were found in the STZ–Cd induced diabetic nephrotoxic rats. The administration of myricetin significantly normalizes the carbohydrate metabolic products like glucose, glycated hemoglobin, glycogen phosphorylase and gluconeogenic enzymes and renal function markers with increase insulin, glycogen, glycogen synthase and insulin signaling molecule expression like glucose transporter-2 (GLUT-2), glucose transporter-4 (GLUT-4), insulin receptor-1 (IRS-1), insulin receptor-2 (IRS-2) and protein kinase B (PKB). Based on the data, the protective effect of myricetin was confirmed by its histological annotation of the pancreas, liver and kidney tissues. These findings suggest that myricetin improved carbohydrate metabolism which subsequently enhances glucose utilization and renal function in STZ–Cd induced diabetic nephrotoxic rats. - Highlights: • Diabetic rats are more susceptible to cadmium nephrotoxicity. • Cadmium plays as a cumulative

  20. Protective effect of bioflavonoid myricetin enhances carbohydrate metabolic enzymes and insulin signaling molecules in streptozotocin–cadmium induced diabetic nephrotoxic rats

    International Nuclear Information System (INIS)

    Kandasamy, Neelamegam; Ashokkumar, Natarajan

    2014-01-01

    Diabetic nephropathy is the kidney disease that occurs as a result of diabetes. The present study was aimed to evaluate the therapeutic potential of myricetin by assaying the activities of key enzymes of carbohydrate metabolism, insulin signaling molecules and renal function markers in streptozotocin (STZ)–cadmium (Cd) induced diabetic nephrotoxic rats. After myricetin treatment schedule, blood and tissue samples were collected to determine plasma glucose, insulin, hemoglobin, glycosylated hemoglobin and renal function markers, carbohydrate metabolic enzymes in the liver and insulin signaling molecules in the pancreas and skeletal muscle. A significant increase of plasma glucose, glycosylated hemoglobin, urea, uric acid, creatinine, blood urea nitrogen (BUN), urinary albumin, glycogen phosphorylase, glucose-6-phosphatase, and fructose-1,6-bisphosphatase and a significant decrease of plasma insulin, hemoglobin, hexokinase, glucose-6-phosphate dehydrogenase, glycogen and glycogen synthase with insulin signaling molecule expression were found in the STZ–Cd induced diabetic nephrotoxic rats. The administration of myricetin significantly normalizes the carbohydrate metabolic products like glucose, glycated hemoglobin, glycogen phosphorylase and gluconeogenic enzymes and renal function markers with increase insulin, glycogen, glycogen synthase and insulin signaling molecule expression like glucose transporter-2 (GLUT-2), glucose transporter-4 (GLUT-4), insulin receptor-1 (IRS-1), insulin receptor-2 (IRS-2) and protein kinase B (PKB). Based on the data, the protective effect of myricetin was confirmed by its histological annotation of the pancreas, liver and kidney tissues. These findings suggest that myricetin improved carbohydrate metabolism which subsequently enhances glucose utilization and renal function in STZ–Cd induced diabetic nephrotoxic rats. - Highlights: • Diabetic rats are more susceptible to cadmium nephrotoxicity. • Cadmium plays as a cumulative

  1. Efficacy of turmeric on blood sugar and polyol pathway in diabetic albino rats.

    Science.gov (United States)

    Arun, N; Nalini, N

    2002-01-01

    In the traditional system of medicine, Ayurveda, several spices and herbs are thought to possess medicinal properties. Among the spices, turmeric rhizomes (Curcuma longa. Linn.) are used as flavoring and coloring agents in the Indian diet everyday. In this research, we studied the effect of turmeric and its active principle, curcumin, on diabetes mellitus in a rat model. Alloxan was used to induce diabetes. Administration of turmeric or curcumin to diabetic rats reduced the blood sugar, Hb and glycosylated hemoglobin levels significantly. Turmeric and curcumin supplementation also reduced the oxidative stress encountered by the diabetic rats. This was demonstrated by the lower levels of TBARS (thiobarbituric acid reactive substances), which may have been due to the decreased influx of glucose into the polyol pathway leading to an increased NADPH/NADP ratio and elevated activity of the potent antioxdiant enzyme GPx. Moreover, the activity of SDH (sorbitol dehydrogenase), which catalyzes the conversion of sorbitol to fructose, was lowered significantly on treatment with turmeric or curcumin. These results also appeared to reveal that curcumin was more effective in attenuating diabetes mellitus related changes than turmeric.

  2. Fish hemoglobins

    OpenAIRE

    Souza,P.C. de; Bonilla-Rodriguez,G.O.

    2007-01-01

    Vertebrate hemoglobin, contained in erythrocytes, is a globular protein with a quaternary structure composed of 4 globin chains (2 alpha and 2 beta) and a prosthetic group named heme bound to each one. Having myoglobin as an ancestor, hemoglobin acquired the capacity to respond to chemical stimuli that modulate its function according to tissue requirements for oxygen. Fish are generally submitted to spatial and temporal O2 variations and have developed anatomical, physiological and biochemica...

  3. Point of care hematocrit and hemoglobin in cardiac surgery: a review.

    Science.gov (United States)

    Myers, Gerard J; Browne, Joe

    2007-05-01

    The use of point-of-care blood gas analyzers in cardiac surgery has been on the increase over the past decade. The availability of these analyzers in the operating room and post-operative intensive care units eliminates the time delays to transport samples to the main laboratory and reduces the amount of blood sampled to measure such parameters as electrolytes, blood gases, lactates, glucose and hemoglobin/hematocrit. Point-of-care analyzers also lead to faster and more reliable clinical decisions while the patient is still on the heart lung machine. Point-of-care devices were designed to provide safe, appropriate and consistent care of those patients in need of rapid acid/base balance and electrolyte management in the clinical setting. As a result, clinicians rely on their values to make decisions regarding ventilation, acid/base management, transfusion and glucose management. Therefore, accuracy and reliability are an absolute must for these bedside analyzers in both the cardiac operating room and the post-op intensive care units. Clinicians have a choice of two types of technology to measure hemoglobin/hematocrit during bypass, which subsequently determines their patient's level of hemodilution, as well as their transfusion threshold. All modern point-of-care blood gas analyzers measure hematocrit using a technology called conductivity, while other similar devices measure hemoglobin using a technology called co-oximetry. The two methods are analyzed and compared in this review. The literature indicates that using conductivity to measure hematocrit during and after cardiac surgery could produce inaccurate results when hematocrits are less than 30%, and, therefore, result in unnecessary homologous red cell transfusions in some patients. These inaccuracies are influenced by several factors that are common and unique to cardiopulmonary bypass, and will also be reviewed here. It appears that the only accurate, consistent and reliable method to determine hemodilution

  4. Treatment of β-Thalassemia/Hemoglobin E with Antioxidant Cocktails Results in Decreased Oxidative Stress, Increased Hemoglobin Concentration, and Improvement of the Hypercoagulable State

    Directory of Open Access Journals (Sweden)

    Orn-uma Yanpanitch

    2015-01-01

    Full Text Available Studies on the antioxidant treatment for thalassemia have reported variable outcomes. However, treatment of thalassemia with a combination of hydrophobic and hydrophilic antioxidants and an iron chelator has not been studied. This study investigated the effects of antioxidant cocktails for the treatment of β-thalassemia/hemoglobin E (HbE, which is the most common form of β-thalassemia in Southeast Asia. Sixty patients were divided into two groups receiving N-acetylcysteine, deferiprone, and either curcuminoids (CUR or vitamin E (Vit-E, and their hematological parameters, iron load, oxidative stress, and blood coagulation potential were evaluated. Patients were classified as responders if they showed the improvements of the markers of iron load and oxidative stress, otherwise as nonresponders. During treatment, the responders in both groups had significantly decreased iron load, oxidative stress, and coagulation potential and significantly increased antioxidant capacity and hemoglobin concentration. The significantly maximum increase (P<0.01 in hemoglobin concentration was 11% at month 4 in CUR group responders and 10% at month 10 in Vit-E group responders. In conclusion, the two antioxidant cocktails can improve anemia, iron overload, oxidative stress, and hypercoagulable state in β-thalassemia/HbE.

  5. Salivary tissue inhibitor of metalloproteinases-1 localization and glycosylation profile analysis

    DEFF Research Database (Denmark)

    Holten-Andersen, Lars; Thaysen-Andersen, Morten; Jensen, Siri Beier

    2011-01-01

    tissue samples (four parotid gland and four submandibular gland biopsies) were analysed for the presence of TIMP-1 mRNA and protein expression. To assess TIMP-1 glycosylation profiles in blood and saliva, the protein was isolated from plasma and unstimulated and stimulated whole saliva as well...... as stimulated parotid and submandibular saliva and analysed by MALDI-TOF mass spectrometry. TIMP-1 protein was demonstrated in mucous acinar cells of the submandibular gland and in ductal cells of both the parotid and submandibular gland. However, no TIMP-1 mRNA was detected in any of these cells...

  6. Hemoglobin and hematocrit at the end of hemodialysis: a better way to adjust erythropoietin dose?

    Science.gov (United States)

    Rangel, Erika B; Andreoli, Maria Claudia; Matos, Ana Cristina C; Guimarães-Souza, Nadia K; Mallet, Ana Cláudia; Carneiro, Fabiana D; Santos, Bento C

    2010-04-01

    A severe disadvantage of administration of recombinant human erythropoietin to hemodialysis patients has been reported. A significant correlation has been shown with hemoglobin values determined online by use of the blood volume monitor (BVM) and by laboratory measurement. Online hemoglobin and hematocrit were measured by use of the BVM during hemodialysis session. Data were analyzed by t test and statistical significance was defined as a P of hemoglobin and hematocrit from 11.6 +/- 1.9 to 13.9 +/- 2.4 g/dL (17.4 +/- 7.1%, P = 0.02) and from 34.4 +/- 6.8 to 42 +/- 8.3% (20.6 +/- 8.8%, P = 0.022), respectively, were observed from the beginning to the end of dialysis. We hypothesize that a new strategy for adjusting erythropoietin dose may be based on hemoglobin and hematocrit values evaluated at the end of hemodialysis, when patients are no longer hypervolemic. Inadvertent high levels of hemoglobin could be one explanation why patients present higher rates of cardiovascular and access-related events, especially when monitored online by use of the BVM to achieve the dry weight.

  7. Glycosylation Helps Cellulase Enzymes Bind to Plant Cell Walls (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2012-06-01

    Computer simulations suggest a new strategy to design enhanced enzymes for biofuels production. Large-scale computer simulations predict that the addition of glycosylation on carbohydrate-binding modules can dramatically improve the binding affinity of these protein domains over amino acid mutations alone. These simulations suggest that glycosylation can be used as a protein engineering tool to enhance the activity of cellulase enzymes, which are a key component in the conversion of cellulose to soluble sugars in the production of biofuels. Glycosylation is the covalent attachment of carbohydrate molecules to protein side chains, and is present in many proteins across all kingdoms of life. Moreover, glycosylation is known to serve a wide variety of functions in biological recognition, cell signaling, and metabolism. Cellulase enzymes, which are responsible for deconstructing cellulose found in plant cell walls to glucose, contain glycosylation that when modified can affect enzymatic activity-often in an unpredictable manner. To gain insight into the role of glycosylation on cellulase activity, scientists at the National Renewable Energy Laboratory (NREL) used computer simulation to predict that adding glycosylation on the carbohydrate-binding module of a cellulase enzyme dramatically boosts the binding affinity to cellulose-more than standard protein engineering approaches in which amino acids are mutated. Because it is known that higher binding affinity in cellulases leads to higher activity, this work suggests a new route to designing enhanced enzymes for biofuels production. More generally, this work suggests that tuning glycosylation in cellulase enzymes is a key factor to consider when engineering biochemical conversion processes, and that more work is needed to understand how glycosylation affects cellulase activity at the molecular level.

  8. Oxygen binding properties of hemoglobin from the white rhinoceros (beta 2-GLU) and the tapir.

    Science.gov (United States)

    Baumann, R; Mazur, G; Braunitzer, G

    1984-04-01

    The beta-chain of rhinoceros hemoglobin contains glutamic acid at position beta 2, and important site for the binding of organic phosphates. We have investigated the oxygen binding properties of this hemoglobin and its interaction with ATP, 2,3-diphosphoglycerate, CO2 and chloride. The results show that the presence of GLU at position beta 2 nearly abolishes the effect of organic phosphates and CO2, whereas the oxygen-linked binding of chloride is not affected. Thus rhinoceros hemoglobin has only protons and chloride anions as major allosteric effectors for the control of its oxygen affinity. From the results obtained with hemoglobin solutions it can be calculated that the blood oxygen affinity of the rhinoceros must be rather high with a P50 of about 20 torr at pH 7.4 and 37 degrees C, which conforms with observations obtained for other large mammals.

  9. Optical Spectra of Hemoglobin Taken from Alcohol Dependent Humans

    OpenAIRE

    Dudok K.; Dudok T.; Vlokh I.; Vlokh R.

    2005-01-01

    Optical spectra of CNMetHb and CNMetHb-Coomassi G-250, taken from the blood of humans with alcohol dependence, are studied in the spectral range of 450–750nm. The shifts in the spectral absorption maxima of CNMetHb-Coomassi G-250 complexes are observed for the diseased persons with alcohol dependence. The obtained results show that the hemoglobin structure of alcohol dependent humans is changed.

  10. Hemoglobin C, S-C, and E Diseases

    Science.gov (United States)

    ... quickly than others, resulting in chronic anemia. Hemoglobin C disease Hemoglobin C disease occurs mostly in blacks. ... a common complication of hemoglobin C disease. Hemoglobin S-C disease Hemoglobin S-C disease occurs in people who ...

  11. Adult, embryonic and fetal hemoglobin are expressed in human glioblastoma cells.

    Science.gov (United States)

    Emara, Marwan; Turner, A Robert; Allalunis-Turner, Joan

    2014-02-01

    Hemoglobin is a hemoprotein, produced mainly in erythrocytes circulating in the blood. However, non-erythroid hemoglobins have been previously reported in other cell types including human and rodent neurons of embryonic and adult brain, but not astrocytes and oligodendrocytes. Human glioblastoma multiforme (GBM) is the most aggressive tumor among gliomas. However, despite extensive basic and clinical research studies on GBM cells, little is known about glial defence mechanisms that allow these cells to survive and resist various types of treatment. We have shown previously that the newest members of vertebrate globin family, neuroglobin (Ngb) and cytoglobin (Cygb), are expressed in human GBM cells. In this study, we sought to determine whether hemoglobin is also expressed in GBM cells. Conventional RT-PCR, DNA sequencing, western blot analysis, mass spectrometry and fluorescence microscopy were used to investigate globin expression in GBM cell lines (M006x, M059J, M059K, M010b, U87R and U87T) that have unique characteristics in terms of tumor invasion and response to radiotherapy and hypoxia. The data showed that α, β, γ, δ, ζ and ε globins are expressed in all tested GBM cell lines. To our knowledge, we are the first to report expression of fetal, embryonic and adult hemoglobin in GBM cells under normal physiological conditions that may suggest an undefined function of those expressed hemoglobins. Together with our previous reports on globins (Ngb and Cygb) expression in GBM cells, the expression of different hemoglobins may constitute a part of series of active defence mechanisms supporting these cells to resist various types of treatments including chemotherapy and radiotherapy.

  12. [Positive Distribution Rate of Coombs Test in Patients with Clinical Anemia and Blood Transfusion and Its Effect on Clinical Blood Transfusion].

    Science.gov (United States)

    Wu, Gang; Duan, Yu-Han

    2018-02-01

    To study the positive distribution rate of Coombs test in patients with clinical anemia and blood transfusion, and its effect on clinical blood transfusion. Seventy patients with hemoglobin level in the normal range were enrolled into control group, while 130 patients with anemia or blood transfusion who' s hemoglobin level was lower comfirmed by micro-column gel antihuman globin detection card and 70 surgical patients with anemia or blood transfusion who' s hemoglobin level was lower comfirmed by micro-column gel anti-human globin card were enrolled into anemia or blood transfusion (A or BT) group. And coomb' s test performed for all the patients, in which the positive patients in Department of Internal Medicine need to be re-typed. Among 70 surgical patients with anemia or blood transfusion, 14 cases were directly detected to be anti-human globine positive with detection rate 20%; among 130 internal medicine patients with anemia or blood transfusion, 54 cases were directly detected to be anti-human globine positive with detection rate 41.4%. Among 270 cases, the highest positive rate (66.7%) was observed in patients with 50-59 g/L of hemoglobin. According to type test, the samples of 54 patients with anemia in Department of Internal Medicine, who were directly selected to be anti-human globin positive, could be divided into anti-C3d(7 cases, accounting for 13.0%), anti-IgG(12 cases accounting for, 22.2%) and anti-C3d+anti-IgG(35 cases, accounting for 64.8%), while according to diseases, the anti-human globin positive ratio was high in tumor cancer, hephropathy and gastroenteropathy patients, and patients in intensive care unit, moreover the blood transfusion frequency of these patients was higher than that of patients with anti-human globin negative(Pblood transfusion, so as to ensure the effectiveness of blood transfusion.

  13. Surface glycosylation profiles of urine extracellular vesicles.

    Directory of Open Access Journals (Sweden)

    Jared Q Gerlach

    Full Text Available Urinary extracellular vesicles (uEVs are released by cells throughout the nephron and contain biomolecules from their cells of origin. Although uEV-associated proteins and RNA have been studied in detail, little information exists regarding uEV glycosylation characteristics. Surface glycosylation profiling by flow cytometry and lectin microarray was applied to uEVs enriched from urine of healthy adults by ultracentrifugation and centrifugal filtration. The carbohydrate specificity of lectin microarray profiles was confirmed by competitive sugar inhibition and carbohydrate-specific enzyme hydrolysis. Glycosylation profiles of uEVs and purified Tamm Horsfall protein were compared. In both flow cytometry and lectin microarray assays, uEVs demonstrated surface binding, at low to moderate intensities, of a broad range of lectins whether prepared by ultracentrifugation or centrifugal filtration. In general, ultracentrifugation-prepared uEVs demonstrated higher lectin binding intensities than centrifugal filtration-prepared uEVs consistent with lesser amounts of co-purified non-vesicular proteins. The surface glycosylation profiles of uEVs showed little inter-individual variation and were distinct from those of Tamm Horsfall protein, which bound a limited number of lectins. In a pilot study, lectin microarray was used to compare uEVs from individuals with autosomal dominant polycystic kidney disease to those of age-matched controls. The lectin microarray profiles of polycystic kidney disease and healthy uEVs showed differences in binding intensity of 6/43 lectins. Our results reveal a complex surface glycosylation profile of uEVs that is accessible to lectin-based analysis following multiple uEV enrichment techniques, is distinct from co-purified Tamm Horsfall protein and may demonstrate disease-specific modifications.

  14. SPECTROPHOTOMETRY OF HEMOGLOBIN - ABSORPTION-SPECTRA OF RAT OXYHEMOGLOBIN, DEOXYHEMOGLOBIN, CARBOXYHEMOGLOBIN, AND METHEMOGLOBIN

    NARCIS (Netherlands)

    ZIJLSTRA, WG; BUURSMA, A; FALKE, HE; CATSBURG, JF

    The absorptivity at 540 nm of methemoglobincyanide from rat blood was determined on the basis of iron and found to be equal to the established value for human methemoglobincyanide (11,01/mmol/cm). On this basis the absorption spectra of the common derivatives were determined for rat hemoglobin.

  15. Molecular dynamics simulations indicate that deoxyhemoglobin, oxyhemoglobin, carboxyhemoglobin, and glycated hemoglobin under compression and shear exhibit an anisotropic mechanical behavior.

    Science.gov (United States)

    Yesudasan, Sumith; Wang, Xianqiao; Averett, Rodney D

    2018-05-01

    We developed a new mechanical model for determining the compression and shear mechanical behavior of four different hemoglobin structures. Previous studies on hemoglobin structures have focused primarily on overall mechanical behavior; however, this study investigates the mechanical behavior of hemoglobin, a major constituent of red blood cells, using steered molecular dynamics (SMD) simulations to obtain anisotropic mechanical behavior under compression and shear loading conditions. Four different configurations of hemoglobin molecules were considered: deoxyhemoglobin (deoxyHb), oxyhemoglobin (HbO 2 ), carboxyhemoglobin (HbCO), and glycated hemoglobin (HbA 1C ). The SMD simulations were performed on the hemoglobin variants to estimate their unidirectional stiffness and shear stiffness. Although hemoglobin is structurally denoted as a globular protein due to its spherical shape and secondary structure, our simulation results show a significant variation in the mechanical strength in different directions (anisotropy) and also a strength variation among the four different hemoglobin configurations studied. The glycated hemoglobin molecule possesses an overall higher compressive mechanical stiffness and shear stiffness when compared to deoxyhemoglobin, oxyhemoglobin, and carboxyhemoglobin molecules. Further results from the models indicate that the hemoglobin structures studied possess a soft outer shell and a stiff core based on stiffness.

  16. Customization of Advia 120 thresholds for canine erythrocyte volume and hemoglobin concentration, and effects on morphology flagging results.

    Science.gov (United States)

    Grimes, Carolyn N; Fry, Michael M

    2014-12-01

    This study sought to develop customized morphology flagging thresholds for canine erythrocyte volume and hemoglobin concentration [Hgb] on the ADVIA 120 hematology analyzer; compare automated morphology flagging with results of microscopic blood smear evaluation; and examine effects of customized thresholds on morphology flagging results. Customized thresholds were determined using data from 52 clinically healthy dogs. Blood smear evaluation and automated morphology flagging results were correlated with mean cell volume (MCV) and cellular hemoglobin concentration mean (CHCM) in 26 dogs. Customized thresholds were applied retroactively to complete blood (cell) count (CBC) data from 5 groups of dogs, including a reference sample group, clinical cases, and animals with experimentally induced iron deficiency anemia. Automated morphology flagging correlated more highly with MCV or CHCM than did blood smear evaluation; correlation with MCV was highest using customized thresholds. Customized morphology flagging thresholds resulted in more sensitive detection of microcytosis, macrocytosis, and hypochromasia than default thresholds.

  17. Mössbauer studies of hemoglobin in high altitude polycythemia

    Science.gov (United States)

    Xiufang, Zhang; Linming, Shen; Songsen, Chen; Yuanyuan, Liu; Naifei, Gao; Yuanming, Zheng; Zhaohui, Ao; Liangquan, Shong

    1990-07-01

    The Mössbauer spectra have been measured in erythrocytes from normal adults and the patients with high altitude polycythemia (HAPC). The results indicated that two subspectra “a” and “b”, corresponding to oxy- and deoxyhemoglobin respectively, were present in all blood samples, and a third subspectrum “c” was found to exist in almost all samples from the patients. The parameters of the third subspectra “cl” in most samples from the patients were similar to those of carbon monoxyhemoglobin. The components were considered to be the denatured hemoglobin in RBCs (red blood cells). Together with clinical analysis, a possible mechanism of HAPC has been discussed.

  18. Blood samples in the neutron beam; Blutproben im Neutronenstrahl

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2012-07-01

    Whether crocodile, platypus, man, or chicken: Always the hemoglobin in the red blood cells has the same task. It carries oxygen from the lungs throughout the body. In investigative manner and international team around Dr. Andreas Stadler from the Julic Research Center has deciphered in detail, how and why the hemoglobines of these creatures nevertheless differ. Their findings are among others interesting for the research on artificial blood.

  19. Assessment of changes in plasma hemoglobin and potassium levels in red cell units during processing and storage.

    Science.gov (United States)

    Saini, Nishant; Basu, Sabita; Kaur, Ravneet; Kaur, Jasbinder

    2015-06-01

    Red cell units undergo changes during storage and processing. The study was planned to assess plasma potassium, plasma hemoglobin, percentage hemolysis during storage and to determine the effects of outdoor blood collection and processing on those parameters. Blood collection in three types of blood storage bags was done - single CPDA bag (40 outdoor and 40 in-house collection), triple CPD + SAGM bag (40 in-house collection) and quadruple CPD + SAGM bag with integral leukoreduction filter (40 in-house collection). All bags were sampled on day 0 (day of collection), day 1 (after processing), day 7, day 14 and day 28 for measurement of percentage hemolysis and potassium levels in the plasma of bag contents. There was significant increase in percentage hemolysis, plasma hemoglobin and plasma potassium level in all the groups during storage (p levels during the storage of red blood cells. Blood collection can be safely undertaken in outdoor blood donation camps even in hot summer months in monitored blood transport boxes. SAGM additive solution decreases the red cell hemolysis and allows extended storage of red cells. Prestorage leukoreduction decreases the red cell hemolysis and improves the quality of blood. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Method Development in the Regioselective Glycosylation of Unprotected Carbohydrates

    DEFF Research Database (Denmark)

    Niedbal, Dominika Alina

    and the glycosylations were promoted by tetrabutylammonium bromide. The couplings were completely selective and gave rise to a number of 1,6-linked disaccharides with 1,2- cis-linked orientation. Project 2: Boron-mediated glycosylation of unprotected carbohydrates Boron-mediated regioselective Koenigs...

  1. Relationship between HgbA1c and myocardial blood flow reserve in patients with type 2 diabetes mellitus: noninvasive assessment using real-time myocardial perfusion echocardiography.

    Science.gov (United States)

    Huang, Runqing; Abdelmoneim, Sahar S; Nhola, Lara F; Mulvagh, Sharon L

    2014-01-01

    To study the relationship between glycosylated hemoglobin (HgbA1c) and myocardial perfusion in type 2 diabetes mellitus (T2DM) patients, we prospectively enrolled 24 patients with known or suspected coronary artery disease (CAD) who underwent adenosine stress by real-time myocardial perfusion echocardiography (RTMPE). HgbA1c was measured at time of RTMPE. Microbubble velocity (β min(-1)), myocardial blood flow (MBF, mL/min/g), and myocardial blood flow reserve (MBFR) were quantified. Quantitative MCE analysis was feasible in all patients (272/384 segments, 71%). Those with HgbA1c > 7.1% had significantly lower βreserve and MBFR than those with HgbA1c ≤ 7.1% (P relationship was not significant (r = -0.117, P = 0.129). Using a MBFR cutoff value > 2 as normal, HgbA1c > 7.1% significantly increased the risk for abnormal MBFR, (adjusted odds ratio: 1.92, 95% CI: 1.12-3.35, P = 0.02). Optimal glycemic control is associated with preservation of MBFR as determined by RTMPE, in T2DM patients at risk for CAD.

  2. COMPARATIVE EVALUATION OF HYPOGLYCEMIC EFFECTS OF TWO DIFFERENT PARTS OF BAUHUNIA PURPUREA LINN. PLANT IN STZ-INDUCED DIABETIC ALBINO WISTAR RATS

    Directory of Open Access Journals (Sweden)

    A. K. Brahmachari

    2015-12-01

    Full Text Available The present work was undertaken to study the comparative phytochemical profiles and hypoglycemic effects of Bauhinia purpurea Linn. Barks (BPBE and leaves ethanolic extracts (BPLE in albino wistar rats to validate their ethno medical use in hyperglycemia as well as to explore the better option. Phytochemicals in ethanolic extracts were analyzed by standard natural product chemistry methods. Diabetes was developed in rats by single intraperitoneal injection of Streptozotocin @ 60mg/ Kg bw. Diabetic albino wister rats (n=3 of either sex (150-200gm bw were orally fed with the extracts once daily for 4 weeks. Glibenclamide @ 0.5mg/Kg bw was used as a positive control for comparison. Fasting blood glucose level at 0, 14th and 28th day and hemoglobin and glycosylated hemoglobin on 28th day of experiment were analyzed. Our results show that the extracts contain alkaloids, flavonoids, glycosides, terpenoids, tannins and phenolics. Rats treated with plant extracts show better glucose modulation, decreased hemoglobin glycosylation and improved hemoglobin concentration as compared to diabetic control. The hypoglycemic effect of only BPBE at 420 mgkg-1 on 14th and 28th day is comparable to that of standard drug glibenclamide (P>0.01. The bark extract has been observed to be more potent hypoglycemic agent than leave extract.

  3. Distribution of N-glycosylation sequons in proteins: how apart are they?

    DEFF Research Database (Denmark)

    Rao, Shyama Prasad; Buus, Ole Thomsen; Wollenweber, Bernd

    2011-01-01

    of experimentally confirmed eukaryotic N-glycoproteins we analyzed the relative position and distribution of sequons. N-Glycosylation probability was found to be lower in the termini of protein sequences compared to the mid region. N-glycosylated sequons were found much farther from C terminus compared to the N......N-glycosylation is a common protein modification process, which affects a number of properties of proteins. Little is known about the distribution of N-glycosylation sequons, for example, the distance between glycosylated sites and their position in the protein primary sequence. Using a large set......-terminus of the protein sequence and this effect was more pronounced for NXS sequons. The distribution of sequons, modeled based on balls-in-boxes classical occupancy, showed a near-maximum probability. Considerable proportion of sequons was found within a distance of ten amino acids, indicating that the steric hindrance...

  4. Interaction of thyroid hormone and hemoglobin: nature of the interaction and effect of hemoglobin on thyroid hormone radioimmunoassay

    International Nuclear Information System (INIS)

    Davis, P.J.; Yoshida, K.; Schoenl, M.

    1980-01-01

    Gel filtration of human erythrocyte (RBC) lysate incubated with labeled thyroxine (Tu) or triiodothyronine (Tt) revealed co-elution of a major iodothyronine-binding fraction (R-2) and hemoglobin. Solutions of purified human hemoglobin and Tt also showed co-elution of hormone and hemoglobin. Because hematin and protoporphyrin were shown to bind labeled Tt, the oxygen-binding site on hemoglobin was excluded as the site of iodothyronine-hemoglobin interaction. Analysis of hormone binding by heme and globin moieties showed Tt binding to be limited to the heme fraction. Addition of excess unlabeled Tt to hemoglobin or heme incubated with labeled Tt indicated 75% to 90% of hormone binding was poorly dissociable. These observations suggested that the presence of hemoglobin in RBC lysate or in serum could influence the measurement of Tu and Tt by specific radioimmunoassay (RIA). Subsequent studies of the addition to serum of human hemoglobin revealed a significant reduction in Tt and Tu detectable by RIA in the presence of this protein. The effect was influenced by the concentration of hemoglobin and by duration and temperature of incubations of hemoglobin and serum prior to RIA

  5. Aerobic bacterial microbiota of the conjunctiva in diabetic patients with normal and altered glycated hemoglobin levels in two regions in Brazil

    Directory of Open Access Journals (Sweden)

    Natalia Pimentel Moreno

    2014-12-01

    Full Text Available Purpose: To study the aerobic bacterial microbiota of the conjunctiva in diabetic patients with regard to the management of diabetes, assessed using glycated hemoglobin levels. Methods: A cross-sectional study was conducted using conjunctival smears of diabetic patients from both sexes and with different ages, residing in two different Brazilian cities (Sorocaba and Rio Branco. A control group of non-diabetic patients was also included. The diabetic patients were considered to have controlled diabetes when their glycated hemoglobin level was ≤7% and blood glucose level was ≤126 mg/dL. Patients with non-controlled diabetes were those with glycated hemoglobin levels >7% and blood glucose levels >126 mg/dL. The samples obtained were inoculated in Brain-Heart Infusion broth and in culture media for aerobic bacteria (blood and chocolate agars; bacterial growth was evaluated in a microbiology laboratory. Results: A total of 120 eyes of 120 patients were included in the present study. The percentage of cultures in which bacterial growth was observed was greater in diabetic patients, although the difference was not statistically significant (p=0.103. There was a greater trend toward bacterial growth in the conjunctiva of diabetic patients with altered fasting blood glucose. There was no difference in the frequency of bacterial growth on the conjunctiva between diabetic patients with normal or altered glycated hemoglobin levels. In Sorocaba, conjunctival bacterial growth was similar to that observed in Rio Branco. The microorganism most frequently detected in the present study was Staphylococcus epidermidis, followed by Staphylococcus aureus, Proteus mirabilis, and Escherichia coli. Conclusion: There was no difference between diabetic patients with normal or altered glycated hemoglobin levels. The microorganisms found were similar to those found in studies investigating the conjunctival bacterial flora of diabetic and non-diabetic patients.

  6. Glycemic changes after vitamin D supplementation in patients with type 1 diabetes mellitus and vitamin D deficiency

    International Nuclear Information System (INIS)

    Khalid S Aljabri; Somoa A Bokhari; Murtadha J. Khan

    2010-01-01

    A prospective, nonblinded and nonrandomized controlled trial was conducted to test the hypothesis that vitamin D supplementation would improve glycemic control in patients with type 1 diabetes mellitus who have vitamin D deficiency. Patients and 0 Eighty patients with type 1 diabetes mellitus who had 25-hydroxyvitamin D levels less than 50 nmol/L were assigned to receive 4000 IU of vitamin D3. Calcium supplements were provided to ensure a total calcium intake of 1200 mg/d. Glycosylated hemoglobin and 25-hydroxyvitamin D levels were measured at baseline and at 12 weeks.There was a significant difference in mean (SD) glycosylated hemoglobin level (%) between the groups that achieved 25-hydroxyvitamin D levels of 51 nmol/L at 12 weeks (P=.02). There was a significant difference in glycosylated hemoglobin change from baseline between the groups that achieved 25-hydroxyvitamin D levels of 51 nmol/L at 12 weeks (P=.04). There was a significant difference in 25-hydroxyvitamin D level between the groups that achieved glycosylated hemoglobin levels of 9.9 at 12 weeks (P=.001). Patients were more likely to achieve lower glycosylated hemoglobin levels at 12 weeks if they had higher 25-hydroxyvitamin D levels at 12 weeks (r=-0.4, P=.001).There was an observed effect of vitamin D supplementation on glycemic control in vitamin D-replete, type 1 diabetes mellitus patients. Further studies are needed to determine if these findings are applicable (Author).

  7. Prion Propagation in Cells Expressing PrP Glycosylation Mutants ▿

    Science.gov (United States)

    Salamat, Muhammad K.; Dron, Michel; Chapuis, Jérôme; Langevin, Christelle; Laude, Hubert

    2011-01-01

    Infection by prions involves conversion of a host-encoded cell surface protein (PrPC) to a disease-related isoform (PrPSc). PrPC carries two glycosylation sites variably occupied by complex N-glycans, which have been suggested by previous studies to influence the susceptibility to these diseases and to determine characteristics of prion strains. We used the Rov cell system, which is susceptible to sheep prions, to generate a series of PrPC glycosylation mutants with mutations at one or both attachment sites. We examined their subcellular trafficking and ability to convert into PrPSc and to sustain stable prion propagation in the absence of wild-type PrP. The susceptibility to infection of mutants monoglycosylated at either site differed dramatically depending on the amino acid substitution. Aglycosylated double mutants showed overaccumulation in the Golgi compartment and failed to be infected. Introduction of an ectopic glycosylation site near the N terminus fully restored cell surface expression of PrP but not convertibility into PrPSc, while PrPC with three glycosylation sites conferred cell permissiveness to infection similarly to the wild type. In contrast, predominantly aglycosylated molecules with nonmutated N-glycosylation sequons, produced in cells expressing glycosylphosphatidylinositol-anchorless PrPC, were able to form infectious PrPSc. Together our findings suggest that glycosylation is important for efficient trafficking of anchored PrP to the cell surface and sustained prion propagation. However, properly trafficked glycosylation mutants were not necessarily prone to conversion, thus making it difficult in such studies to discern whether the amino acid changes or glycan chain removal most influences the permissiveness to prion infection. PMID:21248032

  8. Effect of glycosylation on biodistribution of radiolabeled glucagon-like peptide 1

    International Nuclear Information System (INIS)

    Watanabe, Ayahisa; Nishijima, Ken-ichi; Zhao, Songji; Tamaki, Nagara; Kuge, Yuji; Tanaka, Yoshikazu; Itoh, Takeshi; Takemoto, Hiroshi

    2012-01-01

    Glycosylation is generally applicable as a strategy for increasing the activity of bioactive proteins. In this study, we examined the effect of glycosylation on biodistribution of radiolabeled glucagon-like peptide 1 (GLP-1) as a bioactive peptide for type 2 diabetes. Noninvasive imaging studies were performed using a gamma camera after the intravenous administration of 123 I-GLP-1 or 123 I-α2, 6-sialyl N-acetyllactosamine (glycosylated) GLP-1 in rats. In ex vivo biodistribution studies using 125 I-GLP-1 or 125 I-glycosylated GLP-1, organ samples were measured for radioactivity. Plasma samples were added to 15% trichloroacetic acid (TCA) to obtain TCA-insoluble and TCA-soluble fractions. The radioactivity in the TCA-insoluble and TCA-soluble fractions was measured. In the noninvasive imaging studies, a relatively high accumulation level of 123 I-GLP-1 was found in the liver, which is the major organ to eliminate exogenous GLP-1. The area under the time-activity curve (AUC) of 123 I-glycosylated GLP-1 in the liver was significantly lower (89%) than that of 123 I-GLP-1. These results were consistent with those of ex vivo biodistribution studies using 125 I-labeled peptides. The AUC of 125 I-glycosylated GLP-1 in the TCA-insoluble fraction was significantly higher (1.7-fold) than that of GLP-1. This study demonstrated that glycosylation significantly decreased the distribution of radiolabeled GLP-1 into the liver and increased the concentration of radiolabeled GLP-1 in plasma. These results suggested that glycosylation is a useful strategy for decreasing the distribution into the liver of bioactive peptides as desirable pharmaceuticals. (author)

  9. Comparison of Hemoglobin A1c assay performance on two different commercial systems

    Directory of Open Access Journals (Sweden)

    Jozo Ćorić

    2015-04-01

    Full Text Available Introduction: Glycated hemoglobin (HbA1c is formed by non-enzymatic binding of glucose to the free amino group of the N-terminal end of the ß-chain of hemoglobin A. HbA1c is representative of the mean blood glucose level over three months. The aim of the study was to evaluate the Hemoglobin A1c immunoturbidimetric assay performance on two different commercial systems.Methods: We evaluated the precision and trueness for determination of HbA1c in whole blood. Concentrations of total hemoglobin and HbA1c were evaluated on Dimension Xpand (Siemens and Cobas 501 (Roche analyzers. HbA1c was measured in a latex agglutination inhibition test. Commercial controls Liquichek Diabetes Control Level 1 and Liquichek Diabetes Control Level 2 (Bio Rad at two levels were used for quality control. Analytical validation of HbA1c included: within-run imprecision, between-day imprecision, inaccuracy and comparison determination on the human samples on 2 systems: Dimension Xpand and Cobas 501 analyzers. Results: Within-run imprecision on the commercially controls for Level 1 is 4.5% and Level 2 is 3.2% between-day imprecision on commercially controls is 6.1% Level 1 and 5.1% Level 2 for respectively inac- curacy on commercially controls for Level 1 is 1.8% and Level 2 is 4.8%. Method comparison on human samples shows the correlation coefficient of 0.99.Conclusion: The presented results of the analytical evaluation methods for the determination of HbA1c showed an acceptable accuracy and precision.

  10. Interaction of Jet Fuel Hydrocarbon Components with Red Blood Cells and Hemoglobin

    Science.gov (United States)

    2014-06-24

    Directorate (RHDJ), Wright-Patterson AFB, OH. The authors would like to thank Maj. Paul Eden, Nicole Schaeublin, Christin Grabinski, Dr. Jeff Gearhart...We would also like to thank LtCol. Norman Fox (Laboratory Flight Commander), Mrs. Nersa Loh (Supervisor, Transfusion Services), and Mr. Dan Fischer ...Approximately 7.8 mg of hemoglobin sample was concentrated into a total volume of 5 mL of Fischer PBS pH 7.5 buffer using an Amicon Centrifugal Filter Unit

  11. Investigations on the role of hemoglobin in sulfide metabolism by intact human red blood cells.

    Science.gov (United States)

    Bianco, Christopher L; Savitsky, Anton; Feelisch, Martin; Cortese-Krott, Miriam M

    2018-03-01

    In addition to their role as oxygen transporters, red blood cells (RBCs) contribute to cardiovascular homeostasis by regulating nitric oxide (NO) metabolism via interaction of hemoglobin (Hb) with nitrite and NO itself. RBCs were proposed to also participate in sulfide metabolism. Although Hb is known to react with sulfide, sulfide metabolism by intact RBCs has not been characterized so far. Therefore we explored the role of Hb in sulfide metabolism in intact human RBCs. We find that upon exposure of washed RBCs to sulfide, no changes in oxy/deoxyhemoglobin (oxy/deoxyHb) are observed by UV-vis and EPR spectroscopy. However, sulfide reacts with methemoglobin (metHb), forming a methemoglobin-sulfide (metHb-SH) complex. Moreover, while metHb-SH is stable in cell-free systems even in the presence of biologically relevant thiols, it gradually decomposes to produce oxyHb, inorganic polysulfides and thiosulfate in intact cells, as detected by EPR and mass spectrometry. Taken together, our results demonstrate that under physiological conditions RBCs are able to metabolize sulfide via intermediate formation of a metHb-SH complex, which subsequently decomposes to oxyHb. We speculate that decomposition of metHb-SH is preceded by an inner-sphere electron transfer, forming reduced Hb (which binds oxygen to form oxyHb) and thiyl radical (a process we here define as "reductive sulfhydration"), which upon release, gives rise to the oxidized products, thiosulfate and polysulfides. Thus, not only is metHb an efficient scavenger and regulator of sulfide in blood, intracellular sulfide itself may play a role in keeping Hb in the reduced oxygen-binding form and, therefore, be involved in RBC physiology and function. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  12. Hemoglobin Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... page: https://medlineplus.gov/labtests/hemoglobintest.html Hemoglobin Test To use the sharing features on this page, please enable JavaScript. What is a Hemoglobin Test? A hemoglobin test measures the levels of hemoglobin ...

  13. Optical sensor technology for a noninvasive medical blood diagnosis

    Science.gov (United States)

    Kraitl, Jens; Ewald, Hartmut; Gehring, Hartmut

    2007-02-01

    NIR-spectroscopy and Photoplethysmography (PPG) and is used for a measurement of blood components. The fact that the absorption-coefficients μ a and scattering-coefficients μ s for blood differ at difference wavelengths has been exploited and is used for calculation of the optical absorbability characteristics of human blood yielding information on blood components like hemoglobin and oxygen saturation. The measured PPG time signals and the ratio between the peak to peak pulse amplitudes are used for a measurement of these parameters. A newly developed PMD device has been introduced. The non-invasive in-vivo multi-spectral method is based on the radiation of monochromatic light, emitted by laser diodes, through an area of skin on the finger. Deferrals between the proportions of hemoglobin and plasma in the intravasal volume should be detected photo-electrically by signal-analytic evaluation of the signals. The computed nonlinear coefficients are used for the measurement and calculation of the relative hemoglobin concentration change. Results with this photometric method to measure changes in the hemoglobin concentration were demonstrated during measurements with a hemodynamic model and healthy subjects. The PMD is suitable for non-invasive continuous online monitoring of one or more biologic constituent values. The objective of this development is to reduce the dependence on measurement techniques which require that a sample of blood be withdrawn from the patient for in-vitro analysis. Any invasive method used on the patient to obtain blood is accompanied by problems of inconvenience, stress, and discomfort. The patient is also exposed to the normal risks of infection associated with such invasive methods.

  14. Acute iatrogenic polycythemia induced by massive red blood cell transfusion during subtotal abdominal colectomy

    Directory of Open Access Journals (Sweden)

    David Chiapaikeo

    2015-03-01

    Full Text Available A 46 year old man was transfused ten units of packed red blood cells during subtotal colectomy after intraoperative point-of-care testing values demonstrated hemoglobin values less than seven grams per deciliter (g/dL. A post-operative hemoglobin analyzed in a standard hematologic laboratory revealed a hemoglobin value of 27.8 g/dL. He underwent emergent red blood cell depletion therapy which decreased his hemoglobin to 7.5 g/dL. The physiologic consequences of iatrogenic polycythemia caused by massive transfusion during major abdominal surgery must take into account the fluid shifts that interplay between the osmotic load, viscosity of blood, and postoperative third spacing of fluid. Treatment of acute iatrogenic polycythemia can be effectively accomplished by red blood cell depletion therapy. However, fluid shifts caused by massive transfusion followed by rapid red cell depletion produce a unique physiologic state that is without a well-described algorithm for management.

  15. For People of African, Mediterranean, or Southeast Asian Heritage: Important Information about Diabetes Blood Tests

    Science.gov (United States)

    ... Urodynamic Testing Virtual Colonoscopy Diabetes Blood Tests for People of African, Mediterranean, or Southeast Asian Descent Introduction ... care. What are some common hemoglobin variants? Most people have only one kind of hemoglobin, called hemoglobin ...

  16. Unraveling the Molecular Complexity of O-Glycosylated Endogenous (N-Terminal) pro-B-Type Natriuretic Peptide Forms in Blood Plasma of Patients with Severe Heart Failure.

    Science.gov (United States)

    Halfinger, Bernhard; Hammerer-Lercher, Angelika; Amplatz, Benno; Sarg, Bettina; Kremser, Leopold; Lindner, Herbert H

    2017-01-01

    Currently, N-terminal pro-B-type natriuretic peptide (NT-proBNP) and its physiologically active counterpart, BNP, are most frequently used as biomarkers for diagnosis, prognosis, and disease monitoring of heart failure (HF). Commercial NT-proBNP and BNP immunoassays cross-react to varying degrees with unprocessed proBNP, which is also found in the circulation. ProBNP processing and immunoassay response are related to O-linked glycosylation of NT-proBNP and proBNP. There is a clear and urgent need to identify the glycosylation sites in the endogenously circulating peptides requested by the community to gain further insights into the different naturally occurring forms. The glycosylation sites of (NT-) proBNP (NT-proBNP and/or proBNP) were characterized in leftovers of heparinized plasma samples of severe HF patients (NT-proBNP: >10000 ng/L) by using tandem immunoaffinity purification, sequential exoglycosidase treatment for glycan trimming, β-elimination and Michael addition chemistry, as well as high-resolution nano-flow liquid chromatography electrospray multistage mass spectrometry. We describe 9 distinct glycosylation sites on circulating (NT-) proBNP in HF patients. Differentially glycosylated variants were detected based on highly accurate mass determination and multistage mass spectrometry. Remarkably, for each of the identified proteolytic glycopeptides, a nonglycosylated form also was detectable. Our results directly demonstrate for the first time a rather complex distribution of the endogenously circulating glycoforms by mass spectrometric analysis in HF patients, and show 9 glycosites in human (NT-) proBNP. This information may also have an impact on commercial immunoassays applying antibodies specific for the central region of (NT-) proBNP, which detect mostly nonglycosylated forms. © 2016 American Association for Clinical Chemistry.

  17. Diffuse and localized reflectance measurements of hemoglobin and hematocrit in human skin

    Science.gov (United States)

    Khalil, Omar S.; Wu, Xiaomao; Yeh, Shu-Jen; Jeng, Tzyy-Wen

    2001-05-01

    We conducted visible/near infrared optical measurements on the forearm of human subjects using a commercial diffuse reflectance spectrophotometer, and a breadboard temperature- controlled localized reflectance tissue photometer. Calibration relationships were established between skin reflectance signal and reference blood hemoglobin (Hb) concentration, or hematocrit values (Hct). These were then used to predict Hb and Hct values from optical measurement in a cross validation analysis. Different linear least- squares models for the prediction of Hb and Hct are presented and shows the ability to predict both. It was possible to screen prospective blood donors with low Hb concentration. It was possible to predict anemic subjects in the limited prospective blood donor population.

  18. Blood doping and its detection.

    Science.gov (United States)

    Jelkmann, Wolfgang; Lundby, Carsten

    2011-09-01

    Hemoglobin mass is a key factor for maximal exercise capacity. Some athletes apply prohibited techniques and substances with intent to increase hemoglobin mass and physical performance, and this is often difficult to prove directly. Autologous red blood cell transfusion cannot be traced on reinfusion, and also recombinant erythropoietic proteins are detectable only within a certain timeframe. Novel erythropoietic substances, such as mimetics of erythropoietin (Epo) and activators of the Epo gene, may soon enter the sports scene. In addition, Epo gene transfer maneuvers are imaginable. Effective since December 2009, the World Anti-Doping Agency has therefore implemented "Athlete Biologic Passport Operating Guidelines," which are based on the monitoring of several parameters for mature red blood cells and reticulocytes. Blood doping may be assumed, when these parameters change in a nonphysiologic way. Hematologists should be familiar with blood doping practices as they may play an important role in evaluating blood profiles of athletes with respect to manipulations, as contrasted with the established diagnosis of clinical disorders and genetic variations.

  19. Correlation between maternal and umbilical cord blood in pregnant women of Pokhara Valley: a cross sectional study.

    Science.gov (United States)

    Timilsina, Sameer; Karki, Sirisa; Gautam, Aajeevan; Bhusal, Pujan; Paudel, Gita; Sharma, Deepak

    2018-03-21

    Complete blood count is one of the routinely advised blood investigation during pregnancy. It is also utilized as a diagnostic tool for neonatal anemia, sepsis and determining hemostatic status of the newborn. The present study aims at estimating the complete blood count of maternal and umbilical cord blood at the time of delivery and to establish its correlation. This cross sectional study included 114 mothers and their healthy neonates born through normal vaginal delivery. Complete blood count of umbilical cord blood and maternal blood was estimated using automatic hematology analyzer. The mean maternal and neonatal hemoglobin concentration was 11.14 ± 1.39 g/dL and 16.34 ± 2.01 g/dL respectively. A significant positive correlation was found between maternal and fetal hemoglobin concentration (p correlation between maternal and fetal WBC, RBC and Platelet count was not statistically significant. A significant positive correlation was found between maternal and fetal MCV and MCH while PCV showed a non-significant positive correlation. There was moderately positive correlation between maternal and fetal hemoglobin, MCV and MCH. The cord blood hemoglobin was lower in babies born to anemic mothers. The decrease in hemoglobin followed the severity of anemia, however, the correlation did not exist in anemic mothers. It suggested that fetal hematological parameters are not reflective of maternal hemogram.

  20. A new hemoglobin gene from soybean: a role for hemoglobin in all plants

    DEFF Research Database (Denmark)

    Anderson, C R; Jensen, E O; LLewellyn, D J

    1996-01-01

    We have isolated a new hemoglobin gene from soybean. It is expressed in cotyledons, stems of seedlings, roots, young leaves, and in some cells in the nodules that are associated with the nitrogen-fixing Bradyrhizobium symbiont. This contrasts with the expression of the leghemoglobins, which...... are active only in the infected cells of the nodules. The deduced protein sequence of the new gene shows only 58% similarity to one of the soybean leghemoglobins, but 85-87% similarity to hemoglobins from the nonlegumes Parasponia, Casuarina, and barley. The pattern of expression and the gene sequence...... indicate that this new gene is a nonsymbiotic legume hemoglobin. The finding of this gene in legumes and similar genes in other species strengthens our previous suggestion that genomes of all plants contain hemoglobin genes. The specialized leghemoglobin gene family may have arisen from a preexisting...

  1. Development of a Synthetic Blood Substitute Utilizing Hemoglobin Vesicles.

    Science.gov (United States)

    1992-02-26

    adequately restored. The most widely used blood replacement therapy is the transfusion of whole blood or blood components. Problems associated with these...Hydrogenated Soy-PC was obtained from the American Lecithin Co. (Atlanta, GA) and hydrogenated Egg-PC (IV-40) was supplied by Liposome Technology Inc. (Menlo...Grcssweiner, "Light Dosimetry Model for Phctodvnamic Therapy Treatment Planning," Lasers Surg. Med. 11, 165-173 (1991). 22. P. Parsa. S. L. Jacques, and N

  2. The Emerging Importance of IgG Fab Glycosylation in Immunity.

    Science.gov (United States)

    van de Bovenkamp, Fleur S; Hafkenscheid, Lise; Rispens, Theo; Rombouts, Yoann

    2016-02-15

    Human IgG is the most abundant glycoprotein in serum and is crucial for protective immunity. In addition to conserved IgG Fc glycans, ∼15-25% of serum IgG contains glycans within the variable domains. These so-called "Fab glycans" are primarily highly processed complex-type biantennary N-glycans linked to N-glycosylation sites that emerge during somatic hypermutation. Specific patterns of Fab glycosylation are concurrent with physiological and pathological conditions, such as pregnancy and rheumatoid arthritis. With respect to function, Fab glycosylation can significantly affect stability, half-life, and binding characteristics of Abs and BCRs. Moreover, Fab glycans are associated with the anti-inflammatory activity of IVIgs. Consequently, IgG Fab glycosylation appears to be an important, yet poorly understood, process that modulates immunity. Copyright © 2016 by The American Association of Immunologists, Inc.

  3. Moessbauer studies of hemoglobin in erythrocytes exposed to neutron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Niemiec, Katarzyna; Kaczmarska, Magdalena; Buczkowski, Mateusz [AGH University, Faculty of Physics and Computer Science, Department of Medical Physics and Biophysics (Poland); Fornal, Maria [Collegium Medicum, Jagiellonian University, Department of Internal Medicine and Gerontology (Poland); Pohorecki, Wladyslaw [AGH University, Faculty of Energy and Fuels (Poland); Matlak, Krzysztof; Korecki, Jozef [AGH University, Faculty of Physics and Computer Science, Department of Solid State Physics (Poland); Grodzicki, Tomasz [Collegium Medicum, Jagiellonian University, Department of Internal Medicine and Gerontology (Poland); Burda, Kvetoslava, E-mail: kvetoslava.burda@fis.agh.edu.pl [AGH University, Faculty of Physics and Computer Science, Department of Medical Physics and Biophysics (Poland)

    2012-03-15

    We studied radiation effects on the stability of various states of hemoglobin (Hb) in red blood cells (RBC) irradiated with a very low dose of neutron rays, 50 {mu}Gy. We investigated RBCs isolated from blood of healthy donors. Moessbauer spectroscopy was applied to monitor different forms of Hb. Our results show, for the first time, that oxyhemoglobin (OxyHb) and deoxyhemoglobin (DeoxyHb) are two Hb forms sensitive to such a low neutron radiation. Both Hbs change into a new Hb form (Hb{sub irr}). Additionally, OxyHb transfers into HbOH/H{sub 2}O, which under our experimental conditions is resistant to the action of neutron rays.

  4. An enzymatic method for the rapid measurement of the hemoglobin A1c by a flow-injection system comprised of an electrochemical detector with a specific enzyme-reactor and a spectrophotometer

    International Nuclear Information System (INIS)

    Nanjo, Yoko; Hayashi, Ryuzo; Yao, Toshio

    2007-01-01

    A flow-injection analytical (FIA) system, comprised of an electrochemical detector with a fructosyl-peptide oxidase (FPOX-CET) reactor and a flow-type spectrophotometer, was proposed for the simultaneous measurement of glycohemoglobin and total hemoglobin in blood cell. The blood cell samples were hemolyzed with a surfactant and then treated with protease. In the first stage of operation, total hemoglobin in digested sample was determined spectrophotometrically. In the second stage, fructosyl valyl histidine (FVH) released from glycohemoglobin by the selective proteolysis was determined specifically using the electrochemical detector with the FPOX-CET reactor. The FIA system could be automatically processed at an analytical speed of 40 samples per hour. The proposed assay method could determine selectively only the glycated N-terminal residue of β-chain in glycohemoglobin and total hemoglobin in blood cell. The enzymatic hemoglobin A 1c (HbA 1c ) value calculated by the concentration ratio of the FVH to total hemoglobin, was closely correlated with the HbA 1c values certified by the Japan Diabetic Society (JDS) and the International Federation of Clinical Chemistry (IFCC)

  5. Antimicrobial activity and safety evaluation of peptides isolated from the hemoglobin of chickens.

    Science.gov (United States)

    Hu, Fengjiao; Wu, Qiaoxing; Song, Shuang; She, Ruiping; Zhao, Yue; Yang, Yifei; Zhang, Meikun; Du, Fang; Soomro, Majid Hussain; Shi, Ruihan

    2016-12-05

    Hemoglobin is a rich source of biological peptides. As a byproduct and even wastewater of poultry-slaughtering facilities, chicken blood is one of the most abundant source of hemoglobin. In this study, the chicken hemoglobin antimicrobial peptides (CHAP) were isolated and the antimicrobial and bactericidal activities were tested by the agarose diffusion assay, minimum inhibitory concentration (MIC) analysis, minimal bactericidal concentration (MBC) analysis, and time-dependent inhibitory and bactericidal assays. The results demonstrated that CHAP had potent and rapid antimicrobial activity against 19 bacterial strains, including 9 multidrug-resistant bacterial strains. Bacterial biofilm and NaCl permeability assays, transmission electron microscopy (TEM) and scanning electron microscopy (SEM) were further performed to detect the mechanism of its antimicrobial effect. Additionally, CHAP showed low hemolytic activity, embryo toxicity, and high stability in different temperatures and animal plasma. CHAP may have great potential for expanding production and development value in animal medication, the breeding industry and environment protection.

  6. The effect of gamma-rays on the hemoglobin of whole-body irradiated mice

    International Nuclear Information System (INIS)

    Ashry, H.A.; Selim, N.S.; El-Behay, A.Z.

    1994-01-01

    Changes in the UV-visible absorption spectrum of mouse hemoglobin as a result of whole body irradiation were studied. White albino adult mice were exposed to a Cs-137 γ-source at a dose rate of 47.5 Gy/h to different absorbed dose values ranging from 1 to 8 Gy. Blood specimens were taken 24 h after irradiation. The UV-visible absorption spectra of hemoglobin of irradiated and control mice were measured in the wavelength range from 200 to 700 nm. The obtained results showed significant changes in the bands measured at 340 nm, in the Soret band measured at 410 nm, also, the α- and β-bands measured at 537 and 572 nm showed significant decrease in intensity with the absorbed dose increase. The absorbance measured at 630 nm showed no significant changes. The radiation effect on the animal hemoglobin was discussed on the basis of the obtained results. (Author)

  7. TRUNCATED OR 2/2 HEMOGLOBINS : A NEW CLASS OF GLOBINS WITH NOVEL STRUCTURE AND FUNCTION

    Directory of Open Access Journals (Sweden)

    Amit Kumar

    2013-06-01

    Full Text Available Bright red hemoglobins, the most well-known paradigm in protein science, seem to be ubiquitous in nature. With advances in modern tools and techniques, discovery of new globins at a rapid pace has expanded this family. With every discovery, new insights emerged regarding their novel structure, function and several other characteristics previously not observed for hemoglobins. Even the classical function unanimously assigned to hemoglobins – oxygen transport and storage – needed re-evaluation. The ability of this class of proteins to show responses against various gaseous ligands, even the poisonous ones, indicate that it is obviously as ancient as life. As organisms evolved, hemoglobins also evolved, and accumulated a great degree of diversity in all aspects. The classical globin fold is very unique with 3-on-3 alpha helical bundle as observed in the traditional oxygen-transport hemoglobins like myoglobin, human blood hemoglobin and leghemoglobins in plants. However, a class of the newly discovered hemoglobins, which dominate the superfamily and appears ancient in origin mostly have 2-on-2 fold, commonly termed as “truncated” hemoglobins. These hemoglobins are phylogenetically distinct from their classical counterparts and are often shorter in their polypeptide length by 20-40 residues mainly due to a lack of short A helix, D helix and F helix. However, hemoglobins with 2-on-2 fold were also later found to have polypeptide chain lengths similar in size to classical globins. Disordered pre-F helix region, conserved glycine motifs and other key residues and apolar tunnels through their protein matrix for migration of ligands are some unique characteristics features of these truncated hemoglobins. Some of these are also hexacoordinated at heme iron where an amino acid from within the protein coordinates heme iron in absence of a ligand. These hemoglobins are well known for their high affinity towards ligand and have a diverse mechanism of

  8. Non-invasive hemoglobin monitoring.

    Science.gov (United States)

    Joseph, Bellal; Haider, Ansab; Rhee, Peter

    2016-09-01

    Technology has transformed the practice of medicine and surgery in particular over the last several decades. This change in practice has allowed diagnostic and therapeutic tests to be performed less invasively. Hemoglobin monitoring remains one of the most commonly performed diagnostic tests in the United States. Recently, non-invasive hemoglobin monitoring technology has gained popularity. The aim of this article is to review the principles of how this technology works, pros and cons, and the implications of non-invasive hemoglobin technology particularly in trauma surgery. Copyright © 2015 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  9. Frequency and risk factors associated with hypomagnesaemia in hypokalemic type-2 diabetic patients

    International Nuclear Information System (INIS)

    Shardha, A.K.; Vaswani, A.S.; Fraz, A.; Alam, M.T.; Kumar, P.

    2014-01-01

    Objective: To determine the frequency and factors associated with hypomagnesaemia in hypokalemic type-2 diabetic patients presenting at Civil Hospital, Karachi. Study Design: A cross-sectional study. Place and Duration of Study: Department of Medicine and Diabetic Clinic of Civil Hospital and Dow Medical College, Karachi, from November 2010 to May 2011. Methodology: A total of 358 adult type-2 diabetics with hypokalemia were selected for this study. With aseptic measures, venous blood was collected for serum magnesium, potassium, HDLc, LDLc Triglyceride (TGs) and glycosylated hemoglobin (HbA1c) from each subject after an overnight fasting and was analyzed on Roche Hitachi 820 Photo Spectrometry. The data was analyzed on SPSS version 17 to determine the factors associated with hypomagnesaemia like duration of diabetes, Body Mass Index (BMI), diabetic nephropathy, HDLc, LDLc Triglyceride (TGs) and glycosylated hemoglobin (HbA1c) level. Results: Mean age of study population was 55.62 +- 9.9 years. Most of them (n=228, 63.7%) were males. Out of the 358 subjects, 198 (55.3%) had hypomagnesaemia. There was significant association between hypomagnesaemia with duration of diabetes, Body Mass Index (BMI), diabetic nephropathy, HDLc, LDLc Triglyceride (TGs) and glycosylated hemoglobin (HbA1c) level. Conclusion: Hypomagnesaemia is very common in type-2 diabetic hypokalemic patients. Therefore, it should be routinely sought by the clinicians. Early recognition and subsequent treatment of hypomagnesaemia may help in better glycemic control, may delay the chronic complications and decrease the mortality in diabetic hypokalemic patients. (author)

  10. Deciphering a pathway of Halobacterium salinarum N-glycosylation

    Science.gov (United States)

    Kandiba, Lina; Eichler, Jerry

    2015-01-01

    Genomic analysis points to N-glycosylation as being a common posttranslational modification in Archaea. To date, however, pathways of archaeal N-glycosylation have only been described for few species. With this in mind, the similarities of N-linked glycans decorating glycoproteins in the haloarchaea Haloferax volcanii and Halobacterium salinarum directed a series of bioinformatics, genetic, and biochemical experiments designed to describe that Hbt. salinarum pathway responsible for biogenesis of one of the two N-linked oligosaccharides described in this species. As in Hfx. volcanii, where agl (archaeal glycosylation) genes that encode proteins responsible for the assembly and attachment of a pentasaccharide to target protein Asn residues are clustered in the genome, Hbt. salinarum also contains a group of clustered homologous genes (VNG1048G-VNG1068G). Introduction of these Hbt. salinarum genes into Hfx. volcanii mutant strains deleted of the homologous sequence restored the lost activity. Moreover, transcription of the Hbt. salinarum genes in the native host, as well as in vitro biochemical confirmation of the predicted functions of several of the products of these genes provided further support for assignments made following bioinformatics and genetic experiments. Based on the results obtained in this study, the first description of an N-glycosylation pathway in Hbt. salinarum is offered. PMID:25461760

  11. Neuronal glycosylation differentials in normal, injured and chondroitinase-treated environments

    International Nuclear Information System (INIS)

    Kilcoyne, Michelle; Sharma, Shashank; McDevitt, Niamh; O’Leary, Claire; Joshi, Lokesh; McMahon, Siobhán S.

    2012-01-01

    Highlights: ► Carbohydrates are important in the CNS and ChABC has been used for spinal cord injury (SCI) treatment. ► Neuronal glycosylation in injury and after ChABC treatment is unknown. ► In silico mining verified that glyco-related genes were differentially regulated after SCI. ► In vitro model system revealed abnormal sialylation in an injured environment. ► The model indicated a return to normal neuronal glycosylation after ChABC treatment. -- Abstract: Glycosylation is found ubiquitously throughout the central nervous system (CNS). Chondroitin sulphate proteoglycans (CSPGs) are a group of molecules heavily substituted with glycosaminoglycans (GAGs) and are found in the extracellular matrix (ECM) and cell surfaces. Upon CNS injury, a glial scar is formed, which is inhibitory for axon regeneration. Several CSPGs are up-regulated within the glial scar, including NG2, and these CSPGs are key inhibitory molecules of axonal regeneration. Treatment with chondroitinase ABC (ChABC) can neutralise the inhibitory nature of NG2. A gene expression dataset was mined in silico to verify differentially regulated glycosylation-related genes in neurons after spinal cord injury and identify potential targets for further investigation. To establish the glycosylation differential of neurons that grow in a healthy, inhibitory and ChABC-treated environment, we established an indirect co-culture system where PC12 neurons were grown with primary astrocytes, Neu7 astrocytes (which overexpress NG2) and Neu7 astrocytes treated with ChABC. After 1, 4 and 8 days culture, lectin cytochemistry of the neurons was performed using five fluorescently-labelled lectins (ECA MAA, PNA, SNA-I and WFA). Usually α-(2,6)-linked sialylation scarcely occurs in the CNS but this motif was observed on the neurons in the injured environment only at day 8. Treatment with ChABC was successful in returning neuronal glycosylation to normal conditions at all timepoints for MAA, PNA and SNA-I staining

  12. Neuronal glycosylation differentials in normal, injured and chondroitinase-treated environments

    Energy Technology Data Exchange (ETDEWEB)

    Kilcoyne, Michelle; Sharma, Shashank [Glycoscience Group, National Centre for Biomedical Engineering Science, National University of Ireland, Galway (Ireland); McDevitt, Niamh; O' Leary, Claire [Anatomy, School of Medicine, National University of Ireland, Galway (Ireland); Joshi, Lokesh [Glycoscience Group, National Centre for Biomedical Engineering Science, National University of Ireland, Galway (Ireland); McMahon, Siobhan S., E-mail: siobhan.mcmahon@nuigalway.ie [Anatomy, School of Medicine, National University of Ireland, Galway (Ireland)

    2012-04-13

    Highlights: Black-Right-Pointing-Pointer Carbohydrates are important in the CNS and ChABC has been used for spinal cord injury (SCI) treatment. Black-Right-Pointing-Pointer Neuronal glycosylation in injury and after ChABC treatment is unknown. Black-Right-Pointing-Pointer In silico mining verified that glyco-related genes were differentially regulated after SCI. Black-Right-Pointing-Pointer In vitro model system revealed abnormal sialylation in an injured environment. Black-Right-Pointing-Pointer The model indicated a return to normal neuronal glycosylation after ChABC treatment. -- Abstract: Glycosylation is found ubiquitously throughout the central nervous system (CNS). Chondroitin sulphate proteoglycans (CSPGs) are a group of molecules heavily substituted with glycosaminoglycans (GAGs) and are found in the extracellular matrix (ECM) and cell surfaces. Upon CNS injury, a glial scar is formed, which is inhibitory for axon regeneration. Several CSPGs are up-regulated within the glial scar, including NG2, and these CSPGs are key inhibitory molecules of axonal regeneration. Treatment with chondroitinase ABC (ChABC) can neutralise the inhibitory nature of NG2. A gene expression dataset was mined in silico to verify differentially regulated glycosylation-related genes in neurons after spinal cord injury and identify potential targets for further investigation. To establish the glycosylation differential of neurons that grow in a healthy, inhibitory and ChABC-treated environment, we established an indirect co-culture system where PC12 neurons were grown with primary astrocytes, Neu7 astrocytes (which overexpress NG2) and Neu7 astrocytes treated with ChABC. After 1, 4 and 8 days culture, lectin cytochemistry of the neurons was performed using five fluorescently-labelled lectins (ECA MAA, PNA, SNA-I and WFA). Usually {alpha}-(2,6)-linked sialylation scarcely occurs in the CNS but this motif was observed on the neurons in the injured environment only at day 8. Treatment

  13. DISAL glycosyl donors for the synthesis of a linear hexasaccharide under mild conditions

    DEFF Research Database (Denmark)

    Petersen, Lars; Laursen, Jane B.; Larsen, K.

    2003-01-01

    The new class of glycosyl donors with a methyl 3,5-dinitrosalicylate (DISAL) anomeric leaving group has proved efficient for glycosylation under strictly neutral, mildly basic, or mildly acidic conditions. Here, we report the synthesis of novel DISAL disaccharide glycosyl donors prepared by easy...... nucleophilic aromatic substitution. These DISAL donors proved efficient in the synthesis of a starch-related hexasaccharide under very mild conditions. Glycosylations proceeded with alpha-selectivity and were compatible with Trt protecting groups....

  14. Flagellar glycosylation in Clostridium botulinum.

    Science.gov (United States)

    Twine, Susan M; Paul, Catherine J; Vinogradov, Evgeny; McNally, David J; Brisson, Jean-Robert; Mullen, James A; McMullin, David R; Jarrell, Harold C; Austin, John W; Kelly, John F; Logan, Susan M

    2008-09-01

    Flagellins from Clostridium botulinum were shown to be post-translationally modified with novel glycan moieties by top-down MS analysis of purified flagellin protein from strains of various toxin serotypes. Detailed analyses of flagellin from two strains of C. botulinum demonstrated that the protein is modified by a novel glycan moiety of mass 417 Da in O-linkage. Bioinformatic analysis of available C. botulinum genomes identified a flagellar glycosylation island containing homologs of genes recently identified in Campylobacter coli that have been shown to be responsible for the biosynthesis of legionaminic acid derivatives. Structural characterization of the carbohydrate moiety was completed utilizing both MS and NMR spectroscopy, and it was shown to be a novel legionaminic acid derivative, 7-acetamido-5-(N-methyl-glutam-4-yl)-amino-3,5,7,9-tetradeoxy-D-glycero-alpha-D-galacto-nonulosonic acid, (alphaLeg5GluNMe7Ac). Electron transfer dissociation MS with and without collision-activated dissociation was utilized to map seven sites of O-linked glycosylation, eliminating the need for chemical derivatization of tryptic peptides prior to analysis. Marker ions for novel glycans, as well as a unique C-terminal flagellin peptide marker ion, were identified in a top-down analysis of the intact protein. These ions have the potential for use in for rapid detection and discrimination of C. botulinum cells, indicating botulinum neurotoxin contamination. This is the first report of glycosylation of Gram-positive flagellar proteins by the 'sialic acid-like' nonulosonate sugar, legionaminic acid.

  15. Extramedullary hematopoiesis and paraplegia in a patient with hemoglobin e-Beta thalassemia.

    Science.gov (United States)

    Alam, M R; Habib, M S; Dhakal, G P; Khan, M R; Rahim, M A; Chowdhury, A J; Mahmud, T K

    2010-07-01

    Extramedullary hematopoiesis (EMH) occurs in patients with various hematologic disorders involving a chronic increase in the production of red blood cells, and is often associated polycythemia vera and sickle cell anaemia, but is less common with thalassemia especially with hemoglobin E-beta thalassemia. Spinal cord compression due to EMH is a extremely rare complication of thalassemia and may present with paraparesis or paraplegia with or without sensory impairment. Treatment options mostly include surgery and/or radiotherapy. Whereas cases presenting with paraplegia have been treated with either surgery or radiotherapy with equal frequency and efficacy, almost all reported cases with paraplegia have been treated with surgery with or without radiation therapy. We hereby report a case of hemoglobin E-beta thalassemia with paraplegia treated successfully with radiotherapy.

  16. Hemoglobin proteolysis in blood-feeding ticks: mapping of multienzyme cascade by functional proteomics

    Czech Academy of Sciences Publication Activity Database

    Horn, Martin; Nussbaumerová, Martina; Šanda, Miloslav; Kovářová, Z.; Srba, J.; Franta, Zdeněk; Sojka, Daniel; Kopáček, Petr; Mareš, Michael

    2009-01-01

    Roč. 276, Suppl. 1 (2009), s. 314-314 ISSN 1742-464X. [FEBS Congress /34/. 04.07.2009-09.07.2009, Praha] R&D Projects: GA MŠk(CZ) LC06009; GA ČR GA203/09/1585; GA AV ČR IAA600960910 Institutional research plan: CEZ:AV0Z40550506; CEZ:AV0Z60220518 Keywords : hemoglobin olysis * tick digestion * Ixodes ricinus Subject RIV: CE - Biochemistry

  17. Short report: evaluation of a simple and inexpensive photometric device for the measurement of hemoglobin

    NARCIS (Netherlands)

    Borrmann, Steffen; Oyakhirome, Sunny; Esser, Gilbert; Trinkle, Cordula; Issifou, Saadou; Grobusch, Martin P.; Krishna, Sanjeev; Kremsner, Peter G.

    2004-01-01

    We have evaluated the accuracy of a simple and inexpensive photometric device (DHT) for the estimation of the blood concentration of hemoglobin by comparison with an automated, high-resolution, flow cytometry-based hematology analyzer (CellDyn 3000) and a centrifugal quantitative buffy coat

  18. Glycogenomics as a mass spectrometry-guided genome-mining method for microbial glycosylated molecules.

    Science.gov (United States)

    Kersten, Roland D; Ziemert, Nadine; Gonzalez, David J; Duggan, Brendan M; Nizet, Victor; Dorrestein, Pieter C; Moore, Bradley S

    2013-11-19

    Glycosyl groups are an essential mediator of molecular interactions in cells and on cellular surfaces. There are very few methods that directly relate sugar-containing molecules to their biosynthetic machineries. Here, we introduce glycogenomics as an experiment-guided genome-mining approach for fast characterization of glycosylated natural products (GNPs) and their biosynthetic pathways from genome-sequenced microbes by targeting glycosyl groups in microbial metabolomes. Microbial GNPs consist of aglycone and glycosyl structure groups in which the sugar unit(s) are often critical for the GNP's bioactivity, e.g., by promoting binding to a target biomolecule. GNPs are a structurally diverse class of molecules with important pharmaceutical and agrochemical applications. Herein, O- and N-glycosyl groups are characterized in their sugar monomers by tandem mass spectrometry (MS) and matched to corresponding glycosylation genes in secondary metabolic pathways by a MS-glycogenetic code. The associated aglycone biosynthetic genes of the GNP genotype then classify the natural product to further guide structure elucidation. We highlight the glycogenomic strategy by the characterization of several bioactive glycosylated molecules and their gene clusters, including the anticancer agent cinerubin B from Streptomyces sp. SPB74 and an antibiotic, arenimycin B, from Salinispora arenicola CNB-527.

  19. Determination Of Ph Including Hemoglobin Correction

    Science.gov (United States)

    Maynard, John D.; Hendee, Shonn P.; Rohrscheib, Mark R.; Nunez, David; Alam, M. Kathleen; Franke, James E.; Kemeny, Gabor J.

    2005-09-13

    Methods and apparatuses of determining the pH of a sample. A method can comprise determining an infrared spectrum of the sample, and determining the hemoglobin concentration of the sample. The hemoglobin concentration and the infrared spectrum can then be used to determine the pH of the sample. In some embodiments, the hemoglobin concentration can be used to select an model relating infrared spectra to pH that is applicable at the determined hemoglobin concentration. In other embodiments, a model relating hemoglobin concentration and infrared spectra to pH can be used. An apparatus according to the present invention can comprise an illumination system, adapted to supply radiation to a sample; a collection system, adapted to collect radiation expressed from the sample responsive to the incident radiation; and an analysis system, adapted to relate information about the incident radiation, the expressed radiation, and the hemoglobin concentration of the sample to pH.

  20. Serum Copper Level Significantly Influences Platelet Count, Lymphocyte Count and Mean Cell Hemoglobin in Sickle Cell Anemia

    Directory of Open Access Journals (Sweden)

    Okocha Chide

    2015-12-01

    Full Text Available Background Changes in serum micro nutrients levels affect a number of critically important metabolic processes; these could potentially influence blood counts and ultimately disease presentation in patients with sickle cell anemia (SCA. Objectives To evaluate the influence of serum micro-nutrients levels; zinc, copper, selenium and magnesium on blood counts in steady state SCA patients. Methods A cross sectional study that involved 28 steady state adult SCA subjects. Seven milliliters (mls of blood was collected; 3 mls was for hemoglobin electrophoresis and full blood count determination while 4 mls was for measurement of serum micro nutrients levels, by the atomic absorption spectrophotometry. Correlation between serum micro-nutrient levels and blood counts was done by the Pearson’s linear regression. Ethical approval was obtained from the institutional review board and each participant gave informed consent. All data was analyzed by SPSS software version 20. Results There was a significant correlation between serum copper levels and mean cell hemoglobin (MCH, platelet and lymphocyte counts (r = 0.418; P = 0.02, r = -0.376; P = 0.04 and r = -0.383; P = 0.04, respectively. There were no significant correlations between serum levels of other micro nutrients (selenium, zinc and magnesium and blood counts. Conclusions Copper influences blood count in SCA patients probably by inducing red cell haemolysis, oxidant tissue damage and stimulating the immune system.

  1. Effects of diaspirin cross-linked hemoglobin (DCLHb) during and post-CPR in swine.

    Science.gov (United States)

    Chow, M S; Fan, C; Tran, H; Zhao, H; Zhou, L

    2001-04-01

    The purpose of the study was to test the hypothesis that diaspirin cross-linked hemoglobin (DCLHb) can produce improved resuscitation during cardiac arrest. DCLHb, a derivative of human hemoglobin, has previously been demonstrated to produce a vasopressor response that is associated with increased blood flow to vital organs. In addition, it is an oxygen carrier. These effects may be beneficial to extreme low flow states, such as that during cardiac arrest and cardiopulmonary resuscitation (CPR). Experimental cardiac arrest and CPR were carried out in 32 anesthetized immature pigs. In each animal, ventricular fibrillation was induced for 5 min, followed by 10 min of standard CPR with a pneumatic device and room air ventilation. High (15 ml/kg) and low (5 ml/kg) doses of DCLHb or equivalent volume of normal saline were infused at the beginning of CPR in a random and blind manner. Cardiac output, organ blood flow, aortic pressure, coronary perfusion pressure, blood gases, and lactate concentrations were obtained before and during CPR. Following the 10-min CPR, the animals were defibrillated and the return of spontaneous circulation (ROSC) determined. DCLHb treatment achieved 75% ROSC compared with 25% in the saline group (p CPR significantly improves ROSC. This is most likely related to its improvement in coronary perfusion and myocardial oxygen delivery.

  2. Cost-effective and rapid blood analysis on a cell-phone.

    Science.gov (United States)

    Zhu, Hongying; Sencan, Ikbal; Wong, Justin; Dimitrov, Stoyan; Tseng, Derek; Nagashima, Keita; Ozcan, Aydogan

    2013-04-07

    We demonstrate a compact and cost-effective imaging cytometry platform installed on a cell-phone for the measurement of the density of red and white blood cells as well as hemoglobin concentration in human blood samples. Fluorescent and bright-field images of blood samples are captured using separate optical attachments to the cell-phone and are rapidly processed through a custom-developed smart application running on the phone for counting of blood cells and determining hemoglobin density. We evaluated the performance of this cell-phone based blood analysis platform using anonymous human blood samples and achieved comparable results to a standard bench-top hematology analyser. Test results can either be stored on the cell-phone memory or be transmitted to a central server, providing remote diagnosis opportunities even in field settings.

  3. Glycated hemoglobin biosensing integration formed on Au nanoparticle-dotted tubular TiO{sub 2} nanoarray

    Energy Technology Data Exchange (ETDEWEB)

    Jain, Utkarsh [Amity Institute of Nanotechnology, Amity University, Noida, 201303, Uttar Pradesh (India); Singh, Anamika [Department of Biotechnology, UIET, Kurukshetra University, Kurukshetra, 136 119, Haryana (India); Kuchhal, Naresh Kumar [Clinical Biochemistry Department, Bio-Diagnostics, Rohini, Delhi, 110085 (India); Chauhan, Nidhi, E-mail: nidhichauhan2007@rediffmail.com [Amity Institute of Nanotechnology, Amity University, Noida, 201303, Uttar Pradesh (India)

    2016-11-16

    Excessive glucose present in the blood of diabetic patients binds with the hemoglobin of red blood cells resulting in the formation of glycated hemoglobin (HbA{sub 1c}). Measurement of HbA{sub 1c} levels may help in identifying the efficacy of the ongoing treatment and hence provide a better control over the disease. In the present study, we have synthesized a sensitive and stable scaffold, which consists of Au nanoparticles (GNPs)-dotted tubular TiO{sub 2}, for the construction of an electrochemical HbA{sub 1c} biosensor. 12-phosphotungstic acid has been used as a reducer after depositing well-dispersed GNPs on TiO{sub 2} nanotubes (TiO{sub 2} NTs) and an electron mediator by accelerating the electron transfer between the conductor and protein. The fabricated electrode was characterized using scanning electron microscopy (SEM), cyclic voltammetry (CV), Fourier transform infrared spectroscopy (FTIR) and electrochemical impedance spectroscopic analysis (EIS). Biosensor exhibited low detection limit (0.5 μM), fast response time (3 s) and wide linearity (from 0.5 to 2000 μM). The working electrode was used 100 times over 4 months, when stored at 4 °C. The HbA1c biosensor was then effectively used to measure the % of HbA{sub 1c} in the blood of apparently healthy persons and diabetic patients. - Highlights: • Fabrication of a highly sensitive and stable sensing interface consisting of gold nanoparticles (GNPs) and tubular TiO2. • Biosensor exhibited low detection limit (0.5 μM). • The half life of electrode was 4 months. • Biosensor was suitable for detection of glycated hemoglobin in whole blood.

  4. Effect of yogic exercise on superoxide dismutase levels in diabetics

    Directory of Open Access Journals (Sweden)

    Mahapure Hemant

    2008-01-01

    Full Text Available Context: Reactive oxygen species are known to aggravate disease progression. To counteract their harmful effects, the body produces various antioxidant enzymes, viz , superoxide dismutase, glutathione reductase etc. Literature reviews revealed that exercises help to enhance antioxidant enzyme systems; hence, yogic exercises may be useful to combat various diseases. Aims: This study aims to record the efficacy of yoga on superoxide dismutase, glycosylated hemoglobin (Hb and fasting blood glucose levels in diabetics. Settings and Design: Forty diabetics aged 40-55 years were assigned to experimental (30 and control (10 groups. The experimental subjects underwent a Yoga program comprising of various Asanas (isometric type exercises and Pranayamas (breathing exercises along with regular anti-diabetic therapy whereas the control group received anti-diabetic therapy only. Methods and Material: Heparinized blood samples were used to determine erythrocyte superoxide dismutase (SOD activity and glycosylated Hb levels and fasting blood specimens collected in fluoride Vacutainers were used for assessing blood glucose. Statistical analysis used: Data were analyzed by using 2 x 2 x 3 Factorial ANOVA followed by Scheffe′s posthoc test. Results: The results revealed that Yogic exercise enhanced the levels of Superoxide dismutase and reduced glycosylated Hb and glucose levels in the experimental group as compared to the control group. Conclusion: The findings conclude that Yogic exercises have enhanced the antioxidant defence mechanism in diabetics by reducing oxidative stress.

  5. Safe extension of red blood cell storage life at 4{degree}C

    Energy Technology Data Exchange (ETDEWEB)

    Bitensky, M.; Yoshida, Tatsuro

    1996-04-01

    The project sought to develop methods to extend the storage life of red blood cells. Extended storage would allow donor to self or autologous transfusion, expand and stabilize the blood supply, reduce the cost of medical care and eliminate the risk of transfusion related infections, including a spectrum of hepatitides (A, B and C) and HIV. The putative cause of red blood cell spoilage at 4 C has been identified as oxidative membrane damage resulting from deoxyhemoglobin and its denaturation products including hemichrome, hemin and Fe{sup 3+}. Trials with carbon monoxide, which is a stabilizer of hemoglobin, have produced striking improvement of red blood cell diagnostics for cells stored at 4 C. Carbonmonoxy hemoglobin is readily converted to oxyhemoglobin by light in the presence of oxygen. These findings have generated a working model and an approach to identify the best protocols for optimal red cell storage and hemoglobin regeneration.

  6. Reticulocyte hemoglobin content (MCHr) in the detection of iron deficiency.

    Science.gov (United States)

    Urrechaga Igartua, Eloísa; Hoffmann, Johannes J M L; Izquierdo-Álvarez, Silvia; Escanero, Jesús F

    2017-09-01

    Blood hemoglobin (Hb) concentration within the reference interval does not exclude iron deficiency (ID): individuals with normal stores lose iron during a long period before their Hb falls below of the level that is defined as anemia. The process entails a decrease of storage iron, shown by serum ferritin below reference range, followed by iron depletion, eventually leading to iron restricted erythropoiesis; consequence of an imbalance between erythropoietic iron requirements and too low supply is a reduction of Hb synthesis in reticulocytes. We study the potential utility of mean reticulocyte hemoglobin content (MCHr), reported by CELL-DYN Sapphire (Abbott Diagnostics) analyzer, in the detection of ID in non-anemic adults. 207 patients with Hb within the reference range were enrolled. ID was defined as Hb>120g/L (women), >130g/L (men) and serum ferritin iron deficient adults. Copyright © 2016 Elsevier GmbH. All rights reserved.

  7. Nonlinear photoacoustic spectroscopy of hemoglobin

    Energy Technology Data Exchange (ETDEWEB)

    Danielli, Amos; Maslov, Konstantin; Favazza, Christopher P.; Xia, Jun; Wang, Lihong V., E-mail: LHWANG@WUSTL.EDU [Optical Imaging Laboratory, Department of Biomedical Engineering, Washington University in St. Louis, One Brookings Drive, St. Louis, Missouri 63130 (United States)

    2015-05-18

    As light intensity increases in photoacoustic imaging, the saturation of optical absorption and the temperature dependence of the thermal expansion coefficient result in a measurable nonlinear dependence of the photoacoustic (PA) signal on the excitation pulse fluence. Here, under controlled conditions, we investigate the intensity-dependent photoacoustic signals from oxygenated and deoxygenated hemoglobin at varied optical wavelengths and molecular concentrations. The wavelength and concentration dependencies of the nonlinear PA spectrum are found to be significantly greater in oxygenated hemoglobin than in deoxygenated hemoglobin. These effects are further influenced by the hemoglobin concentration. These nonlinear phenomena provide insights into applications of photoacoustics, such as measurements of average inter-molecular distances on a nm scale or with a tuned selection of wavelengths, a more accurate quantitative PA tomography.

  8. Nonlinear photoacoustic spectroscopy of hemoglobin.

    Science.gov (United States)

    Danielli, Amos; Maslov, Konstantin; Favazza, Christopher P; Xia, Jun; Wang, Lihong V

    2015-05-18

    As light intensity increases in photoacoustic imaging, the saturation of optical absorption and the temperature dependence of the thermal expansion coefficient result in a measurable nonlinear dependence of the photoacoustic (PA) signal on the excitation pulse fluence. Here, under controlled conditions, we investigate the intensity-dependent photoacoustic signals from oxygenated and deoxygenated hemoglobin at varied optical wavelengths and molecular concentrations. The wavelength and concentration dependencies of the nonlinear PA spectrum are found to be significantly greater in oxygenated hemoglobin than in deoxygenated hemoglobin. These effects are further influenced by the hemoglobin concentration. These nonlinear phenomena provide insights into applications of photoacoustics, such as measurements of average inter-molecular distances on a nm scale or with a tuned selection of wavelengths, a more accurate quantitative PA tomography.

  9. Nonlinear photoacoustic spectroscopy of hemoglobin

    International Nuclear Information System (INIS)

    Danielli, Amos; Maslov, Konstantin; Favazza, Christopher P.; Xia, Jun; Wang, Lihong V.

    2015-01-01

    As light intensity increases in photoacoustic imaging, the saturation of optical absorption and the temperature dependence of the thermal expansion coefficient result in a measurable nonlinear dependence of the photoacoustic (PA) signal on the excitation pulse fluence. Here, under controlled conditions, we investigate the intensity-dependent photoacoustic signals from oxygenated and deoxygenated hemoglobin at varied optical wavelengths and molecular concentrations. The wavelength and concentration dependencies of the nonlinear PA spectrum are found to be significantly greater in oxygenated hemoglobin than in deoxygenated hemoglobin. These effects are further influenced by the hemoglobin concentration. These nonlinear phenomena provide insights into applications of photoacoustics, such as measurements of average inter-molecular distances on a nm scale or with a tuned selection of wavelengths, a more accurate quantitative PA tomography

  10. Nonenzymatic glycosylation of bovine myelin basic protein

    International Nuclear Information System (INIS)

    Hitz, J.B.

    1987-01-01

    In the CNS myelin sheath the nonenzymatic glycosylation reaction (at the early stage of the Amadori product) occurs only with the myelin basic protein and not with the other myelin proteins. This was observed in isolated bovine myelin by in vitro incubation with [ 14 C]-galactose and [ 14 C]-glucose. The respective in-vitro incorporation rates for purified bovine myelin basic protein with D-galactose, D-glucose and D-mannose were 7.2, 2.4 and 2.4 mmoles/mole myelin basic protein per day at 37 0 C. A more rapid, HPLC method was devised and characterized to specifically analyze for the Amadori product. The HPLC method was correlated to the [ 14 C]-sugar incorporation method for myelin basic protein under a set of standard reaction conditions using [ 14 C]-glucose and [ 14 C]-mannose with HPLC values at 1/6 and 1/5 of the [ 14 C]-sugar incorporation method. A novel myelin basic protein purification step has been developed that yields a relativity proteolytic free preparation that is easy to work with, being totally soluble at a neutral pH. Nine new spots appear for a trypsinized glycosylated MBP in the paper peptide map of which eight correspond to positions of the [ 3 H]-labeled Amadori product in affinity isolated peptides. These studies provide a general characterization of and a structural basis for investigations on nonenzymatically glycosylated MBP as well as identifying MBP as the only nonenzymatically glycosylated protein in the CNS myelin sheath which may accumulate during aging, diabetes, and demyelinating diseases in general

  11. A study report of 174 units of placental umbilical cord whole blood transfusion in 62 patients as a rich source of fetal hemoglobin supply in different indications of blood transfusion.

    Science.gov (United States)

    Bhattacharya, N; Mukherijee, K; Chettri, M K; Banerjee, T; Mani, U; Bhattacharya, S

    2001-01-01

    three days of collection and preservation at 1-6 degrees C in a refrigerator), we are of the opinion that this is a safe transfusion protocol which takes advantage of the safety of nature's finest biological sieve, i.e., the placenta, as an alternative to adult whole blood transfusion. It also has the advantage of a higher oxygen carrying capacity of fetal hemoglobin in addition to many growth factors and other cytokine filled cord blood plasma along with its hypoantigenicity.

  12. The effect of glycosylation on cytotoxicity of Ibaraki virus nonstructural protein NS3

    Science.gov (United States)

    URATA, Maho; WATANABE, Rie; IWATA, Hiroyuki

    2015-01-01

    The cytotoxicity of Ibaraki virus nonstructural protein NS3 was confirmed, and the contribution of glycosylation to this activity was examined by using glycosylation mutants of NS3 generated by site-directed mutagenesis. The expression of NS3 resulted in leakage of lactate dehydrogenase to the culture supernatant, suggesting the cytotoxicity of this protein. The lack of glycosylation impaired the transport of NS3 to the plasma membrane and resulted in reduced cytotoxicity. Combined with the previous observation that NS3 glycosylation was specifically observed in mammalian cells (Urata et al., Virus Research 2014), it was suggested that the alteration of NS3 cytotoxicity through modulating glycosylation is one of the strategies to achieve host specific pathogenisity of Ibaraki virus between mammals and vector arthropods. PMID:26178820

  13. Hemoglobin, ferritin, vitamin B12 and helicobacter pylori infection: a study in patients underwent upper GI endoscopy at civil hospital karachi

    International Nuclear Information System (INIS)

    Zuberi, B.F.; Asar, S.; Qadeer, R.; Baloch, I.; Saeed, M.

    2007-01-01

    To compare hemoglobin, ferritin, and vitamin B12 levels in patients undergoing upper GI endoscopy according to their Helicobacter pylori status. All patients undergoing upper GI Endoscopy were selected, while patients of active peptic ulcers, malignancy, varices, malabsorption and recent blood donation were excluded. Blood samples for CBC, serum ferritin and vitamin B12 were collected and H.pylori status was ascertained by urease test on gastric biopsy. Differences in mean values of age, ferritin, hemoglobin, MCV and vitamin B12 were done by students t-test. Significant confounding factors were identified on multivariate analysis and were further analyzed by univariate analysis. Two hundred and eighty-five subjects were studied, including 171 males and 114 females. H-pylori was positive in 214 (75.1%) patients. Significantly low levels of hemoglobin (p =0.0), ferritin (p = 0.0) and vitamin B12 (p = 0.0) were found in patients with H-pylori infection. Gender, menopause, contraception and history of peptic ulcer disease were identified as significant confounders. Significantly low levels of hemoglobin, ferritin and vitamin B12 were found in patients with H-pylori infection. (author)

  14. The effect of oral iron with or without multiple micronutrients on hemoglobin concentration and hemoglobin response among nonpregnant Cambodian women of reproductive age: a 2 x 2 factorial, double-blind, randomized controlled supplementation trial.

    Science.gov (United States)

    Karakochuk, Crystal D; Barker, Mikaela K; Whitfield, Kyly C; Barr, Susan I; Vercauteren, Suzanne M; Devlin, Angela M; Hutcheon, Jennifer A; Houghton, Lisa A; Prak, Sophonneary; Hou, Kroeun; Chai, Tze Lin; Stormer, Ame; Ly, Sokhoing; Devenish, Robyn; Oberkanins, Christian; Pühringer, Helene; Harding, Kimberly B; De-Regil, Luz M; Kraemer, Klaus; Green, Tim J

    2017-07-01

    Background: Despite a high prevalence of anemia among nonpregnant Cambodian women, current reports suggest that iron deficiency (ID) prevalence is low. If true, iron supplementation will not be an effective anemia reduction strategy. Objective: We measured the effect of daily oral iron with or without multiple micronutrients (MMNs) on hemoglobin concentration in nonpregnant Cambodian women screened as anemic. Design: In this 2 × 2 factorial, double-blind, randomized trial, nonpregnant women (aged 18-45 y) with hemoglobin concentrations ≤117 g/L (capillary blood) were recruited from 26 villages in Kampong Chhnang province and randomly assigned to receive 12 wk of iron (60 mg; Fe group), MMNs (14 other micronutrients; MMN group), iron plus MMNs (Fe+MMN group), or placebo capsules. A 2 × 2 factorial intention-to-treat analysis with the use of a generalized mixed-effects model was used to assess the effects of iron and MMNs and the interaction between these factors. Results: In July 2015, 809 women were recruited and 760 (94%) completed the trial. Baseline anemia prevalence was 58% (venous blood). Mean (95% CI) hemoglobin concentrations at 12 wk in the Fe, MMN, Fe+MMN, and placebo groups were 121 (120, 121), 116 (116, 117), 123 (122, 123), and 116 (116, 117) g/L, with no iron × MMN interaction ( P = 0.66). Mean (95% CI) increases in hemoglobin were 5.6 g/L (3.8, 7.4 g/L) ( P < 0.001) among women who received iron ( n = 407) and 1.2 g/L (-0.6, 3.0 g/L) ( P = 0.18) among women who received MMNs ( n = 407). The predicted proportions (95% CIs) of women with a hemoglobin response (≥10 g/L at 12 wk) were 19% (14%, 24%), 9% (5%, 12%), 30% (24%, 35%), and 5% (2%, 9%) in the Fe, MMN, Fe+MMN, and placebo groups, respectively. Conclusions: Daily iron supplementation for 12 wk increased hemoglobin in nonpregnant Cambodian women; however, MMNs did not confer additional significant benefit. Overall, ∼24% of women who received iron responded after 12 wk; even fewer would be

  15. Ability of the Masimo pulse CO-Oximeter to detect changes in hemoglobin.

    Science.gov (United States)

    Colquhoun, Douglas A; Forkin, Katherine T; Durieux, Marcel E; Thiele, Robert H

    2012-04-01

    The decision to administer blood products is complex and multifactorial. Accurate assessment of the concentration of hemoglobin [Hgb] is a key component of this evaluation. Recently a noninvasive method of continuously measuring hemoglobin (SpHb) has become available with multi-wavelength Pulse CO-Oximetry. The accuracy of this device is well documented, but the trending ability of this monitor has not been previously described. Twenty patients undergoing major thoracic and lumbar spine surgery were recruited. All patients received radial arterial lines. On the contralateral index finger, a R1 25 sensor (Rev E) was applied and connected to a Radical-7 Pulse CO-Oximeter (both Masimo Corp, Irvine, CA). Blood samples were drawn intermittently at the anesthesia provider's discretion and were analyzed by the operating room satellite laboratory CO-Oximeter. The value of Hgb and SpHb at that time point was compared. Trend analysis was performed by the four quadrant plot technique, testing directionality of change, and Critchley's polar plot method testing both directionality and magnitude of the change in values. Eighty-eight samples recorded at times of sufficient signal quality were available for analysis. Four quadrant plot analysis revealed 94% of data within the quadrants associated with the correct direction change, and 90% of data points lay within the analysis bounds proposed by Critchley. Pulse CO-Oximetry offers an acceptable trend monitor in patients undergoing major spine surgery. Future work should explore the ability of this device to detect large changes in hemoglobin, as well as its applicability in additional surgical and non-surgical patient populations.

  16. N-Glycosylation of Carnosinase Influences Protein Secretion and Enzyme Activity Implications for Hyperglycemia

    NARCIS (Netherlands)

    Riedl, Eva; Koeppel, Hannes; Pfister, Frederick; Peters, Verena; Sauerhoefer, Sibylle; Sternik, Paula; Brinkkoetter, Paul; Zentgraf, Hanswalter; Navis, Gerjan; Henning, Robert H.; Van Den Born, Jacob; Bakker, Stephan J. L.; Janssen, Bart; van der Woude, Fokko J.; Yard, Benito A.

    OBJECTIVE-The (CTG)(n) polymorphism in the serum carnosinase (CN-1) gene affects CN-1 secretion Since CN-1 is heavily glycosylated and glycosylation might influence protein secretion as well, we tested the role of N-glycosylation for CN-1 secretion and enzyme activity. We also tested whether CN-1

  17. Cancer associated aberrant protein o-glycosylation can modify antigen processing and immune response

    DEFF Research Database (Denmark)

    Madsen, Caroline B; Petersen, Cecilie; Lavrsen, Kirstine

    2012-01-01

    Aberrant glycosylation of mucins and other extracellular proteins is an important event in carcinogenesis and the resulting cancer associated glycans have been suggested as targets in cancer immunotherapy. We assessed the role of O-linked GalNAc glycosylation on antigen uptake, processing......, and presentation on MHC class I and II molecules. The effect of GalNAc O-glycosylation was monitored with a model system based on ovalbumin (OVA)-MUC1 fusion peptides (+/- glycosylation) loaded onto dendritic cells co-cultured with IL-2 secreting OVA peptide-specific T cell hybridomas. To evaluate the in vivo...

  18. Hemoglobin Variants: Biochemical Properties and Clinical Correlates

    Science.gov (United States)

    Thom, Christopher S.; Dickson, Claire F.; Gell, David A.; Weiss, Mitchell J.

    2013-01-01

    Diseases affecting hemoglobin synthesis and function are extremely common worldwide. More than 1000 naturally occurring human hemoglobin variants with single amino acid substitutions throughout the molecule have been discovered, mainly through their clinical and/or laboratory manifestations. These variants alter hemoglobin structure and biochemical properties with physiological effects ranging from insignificant to severe. Studies of these mutations in patients and in the laboratory have produced a wealth of information on hemoglobin biochemistry and biology with significant implications for hematology practice. More generally, landmark studies of hemoglobin performed over the past 60 years have established important paradigms for the disciplines of structural biology, genetics, biochemistry, and medicine. Here we review the major classes of hemoglobin variants, emphasizing general concepts and illustrative examples. PMID:23388674

  19. Rapid phenolic O-glycosylation of small molecules and complex unprotected peptides in aqueous solvent

    Science.gov (United States)

    Wadzinski, Tyler J.; Steinauer, Angela; Hie, Liana; Pelletier, Guillaume; Schepartz, Alanna; Miller, Scott J.

    2018-06-01

    Glycosylated natural products and synthetic glycopeptides represent a significant and growing source of biochemical probes and therapeutic agents. However, methods that enable the aqueous glycosylation of endogenous amino acid functionality in peptides without the use of protecting groups are scarce. Here, we report a transformation that facilitates the efficient aqueous O-glycosylation of phenolic functionality in a wide range of small molecules, unprotected tyrosine, and tyrosine residues embedded within a range of complex, fully unprotected peptides. The transformation, which uses glycosyl fluoride donors and is promoted by Ca(OH)2, proceeds rapidly at room temperature in water, with good yields and selective formation of unique anomeric products depending on the stereochemistry of the glycosyl donor. High functional group tolerance is observed, and the phenol glycosylation occurs selectively in the presence of virtually all side chains of the proteinogenic amino acids with the singular exception of Cys. This method offers a highly selective, efficient, and operationally simple approach for the protecting-group-free synthesis of O-aryl glycosides and Tyr-O-glycosylated peptides in water.

  20. High affinity hemoglobin and Parkinson's disease.

    Science.gov (United States)

    Graham, Jeffrey; Hobson, Douglas; Ponnampalam, Arjuna

    2014-12-01

    Parkinson's disease (PD) is a neurodegenerative disorder characterized by the loss of dopaminergic neurons in the substantia nigra (SN) region of the midbrain. Oxidative damage in this region has been shown to play an important role in the pathogenesis of this disease. Human neurons have been discovered to contain hemoglobin, with an increased concentration seen in the neurons of the SN. High affinity hemoglobin is a clinical entity resulting from mutations that create a functional increase in the binding of hemoglobin to oxygen and an inability to efficiently unload it to tissues. This can result in a number of metabolic compensatory changes, including an elevation in circulating hemoglobin and an increase in the molecule 2,3-diphosphoglycerate (2,3-DPG). Population based studies have revealed that patients with PD have elevated hemoglobin as well as 2,3-DPG levels. Based on these observations, we hypothesize that the oxidative damage seen in PD is related to an underlying high affinity hemoglobin subtype. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. SCREENING CORD BLOOD FOR HEMOGLOBINOPATHIES AND THALASSEMIA BY HPLC

    NARCIS (Netherlands)

    VANDERDIJS, FPL; VANDENBERG, GA; SCHERMER, JG; MUSKIET, FD; LANDMAN, H; MUSKIET, FAJ

    We evaluated the use of an HPLC method for screening hemoglobins in cord blood. We studied the genotype frequencies of the structural hemoglobin variants HbS and HbC and the synthesis variants alpha- and beta+-thalassemia in babies born on Curacao. During three months, 67.2% of all (748) newborns

  2. Biochemistry Applied to Everyday Life: Chemical Equilibrium and the Transporting Function of the Hemoglobin

    Directory of Open Access Journals (Sweden)

    Carlos Mario Echeverría Palacio

    2006-12-01

    Full Text Available The hemoglobin is a blood protein which cantransport oxygen, a gas insoluble in water, todifferent organs where it is required for the properfunction; this protein also transports themetabolic products, CO2 and H+ for theirexcretion. This process depends on pH, the BPGconcentration, pO2 and pCO2. The cooperativebinding between hemoglobin and those compoundsand the conformational changes necessaryfor oxygen and CO2 uptake and release inthe specific place where they are required. Abruptchanges of atmospheric pressure associatedwith height and the exposure to other gases suchas CO present in vehicles and closed roomscould compromise the normal functioning of theorganism because their presence affects thetransport function of the hemoglobin. In thispaper, we will explain everyday phenomenarelated to the transport of gases through hemoglobinas a demonstration that a knowledge ofbiochemistry begins to be useful from now on to understand everyday situations and give usan expectation of their value to comprehendmany health problems that would be faced inthe future

  3. Transient spontaneous engraftment of CD34 hematopoietic cord blood stem cells as seen in peripheral blood: treatment of leprosy patients with anemia by placental umbilical cord whole blood transfusion.

    Science.gov (United States)

    Bhattacharya, N

    2006-01-01

    Cord blood, because of its rich mix of fetal and adult hemoglobin, high platelet and white blood cell (WBC) counts, and a plasma filled with cytokine and growth factors, as well as its hypoantigenic nature and altered metabolic profile, has all the potential of a real and safe alternative to adult blood transfusion. Our experience of 74 units (50 ml-146 ml mean, 86 ml +/- 7.6 ml SD, median 80 ml, mean packed cell volume 48 +/- 4.1 SD, mean percent hemoglobin concentration 16.2 g/dl +/- 1.8 g/dl of placental umbilical cord whole blood collection (from 1 April 1999) after lower uterine cesarean section (LUCS) from consenting mothers and transfusion of the same to 16 informed, consenting patients with percent plasma hemoglobin 8 g/dl or less, is presented here. After collection the blood was immediately preserved in the refrigerator and transfused within 72 hours of collection. Fifteen males and one female, aged 12-72 yrs (mean 48.4 yrs) participated: five cases were pausibacillary type (PB) and 11 cases were multibacillary type (MB). The clinical spectrum of the cases varied widely from the tuberculoid to the lepromatous type and one patient presented with gangrene of the leg preceding an auto amputation which was infested with maggots. Each case was approved by the institutional ethical committee and received two to eight units of freshly collected placental umbilical cord blood in one transfusion without encountering any clinical, immunological or non-immunological reaction. Seven days after completion of the placental umbilical cord blood transfusion, the peripheral blood hematopoietic stem cell (CD34) estimation revealed a rise from the pretransfusion base level (.09%), varying from 3.6% to 16.2%, in 75% of the cases, without provoking any clinical graft vs host reaction in any of the leprosy victims. This value returned to normal within three months in most cases.

  4. [Conformation analysis of the N-glycosylation site Asn-X-Thr/Ser in glycoproteins].

    Science.gov (United States)

    Avanov, A Ia; Lipkind, G M

    1990-03-01

    Theoretical conformational analysis of oligopeptides CH3CO-Asn-X-Thr-NHCH3 (X = Gly, Ala, Pro), modelling N-glycosylation site, and their glycosylated derivatives CH3CO-(GlcNAc beta 1-4GlcNAc beta 1) Asn-X-Thr-NHCH3 has been carried out. Active conformations of the site are found, corresponding to structural prerequisities of N-glycosylation: Asn residue's position in beta-turn and hydrogen bond formation between side chains of Asn and Thr/Ser residues. In this case the L conformation of the central residue X is most probable. Since Pro residue does not possess this conformation, sequences with X = Pro are not glycosylated. It is shown that glycosylation of the above-mentioned sites is accompanied by reorientation of the Asn residue's side chains.

  5. Mössbauer studies of hemoglobin in erythrocytes exposed to neutron radiation

    International Nuclear Information System (INIS)

    Niemiec, Katarzyna; Kaczmarska, Magdalena; Buczkowski, Mateusz; Fornal, Maria; Pohorecki, Władysław; Matlak, Krzysztof; Korecki, Józef; Grodzicki, Tomasz; Burda, Kvetoslava

    2012-01-01

    We studied radiation effects on the stability of various states of hemoglobin (Hb) in red blood cells (RBC) irradiated with a very low dose of neutron rays, 50 μGy. We investigated RBCs isolated from blood of healthy donors. Mössbauer spectroscopy was applied to monitor different forms of Hb. Our results show, for the first time, that oxyhemoglobin (OxyHb) and deoxyhemoglobin (DeoxyHb) are two Hb forms sensitive to such a low neutron radiation. Both Hbs change into a new Hb form (Hb irr ). Additionally, OxyHb transfers into HbOH/H 2 O, which under our experimental conditions is resistant to the action of neutron rays.

  6. A computational framework for the automated construction of glycosylation reaction networks.

    Science.gov (United States)

    Liu, Gang; Neelamegham, Sriram

    2014-01-01

    Glycosylation is among the most common and complex post-translational modifications identified to date. It proceeds through the catalytic action of multiple enzyme families that include the glycosyltransferases that add monosaccharides to growing glycans, and glycosidases which remove sugar residues to trim glycans. The expression level and specificity of these enzymes, in part, regulate the glycan distribution or glycome of specific cell/tissue systems. Currently, there is no systematic method to describe the enzymes and cellular reaction networks that catalyze glycosylation. To address this limitation, we present a streamlined machine-readable definition for the glycosylating enzymes and additional methodologies to construct and analyze glycosylation reaction networks. In this computational framework, the enzyme class is systematically designed to store detailed specificity data such as enzymatic functional group, linkage and substrate specificity. The new classes and their associated functions enable both single-reaction inference and automated full network reconstruction, when given a list of reactants and/or products along with the enzymes present in the system. In addition, graph theory is used to support functions that map the connectivity between two or more species in a network, and that generate subset models to identify rate-limiting steps regulating glycan biosynthesis. Finally, this framework allows the synthesis of biochemical reaction networks using mass spectrometry (MS) data. The features described above are illustrated using three case studies that examine: i) O-linked glycan biosynthesis during the construction of functional selectin-ligands; ii) automated N-linked glycosylation pathway construction; and iii) the handling and analysis of glycomics based MS data. Overall, the new computational framework enables automated glycosylation network model construction and analysis by integrating knowledge of glycan structure and enzyme biochemistry. All

  7. A computational framework for the automated construction of glycosylation reaction networks.

    Directory of Open Access Journals (Sweden)

    Gang Liu

    Full Text Available Glycosylation is among the most common and complex post-translational modifications identified to date. It proceeds through the catalytic action of multiple enzyme families that include the glycosyltransferases that add monosaccharides to growing glycans, and glycosidases which remove sugar residues to trim glycans. The expression level and specificity of these enzymes, in part, regulate the glycan distribution or glycome of specific cell/tissue systems. Currently, there is no systematic method to describe the enzymes and cellular reaction networks that catalyze glycosylation. To address this limitation, we present a streamlined machine-readable definition for the glycosylating enzymes and additional methodologies to construct and analyze glycosylation reaction networks. In this computational framework, the enzyme class is systematically designed to store detailed specificity data such as enzymatic functional group, linkage and substrate specificity. The new classes and their associated functions enable both single-reaction inference and automated full network reconstruction, when given a list of reactants and/or products along with the enzymes present in the system. In addition, graph theory is used to support functions that map the connectivity between two or more species in a network, and that generate subset models to identify rate-limiting steps regulating glycan biosynthesis. Finally, this framework allows the synthesis of biochemical reaction networks using mass spectrometry (MS data. The features described above are illustrated using three case studies that examine: i O-linked glycan biosynthesis during the construction of functional selectin-ligands; ii automated N-linked glycosylation pathway construction; and iii the handling and analysis of glycomics based MS data. Overall, the new computational framework enables automated glycosylation network model construction and analysis by integrating knowledge of glycan structure and enzyme

  8. Characteristic emission in glutaraldehyde polymerized hemoglobin

    International Nuclear Information System (INIS)

    Ma Li; Wang Xiaojun

    2011-01-01

    Hemoglobin with different modifications has been investigated using spectroscopic techniques. A new emission at around 371 nm has been observed under excitation of 305 nm from glutaraldehyde polymerized human hemoglobin. Intensity and peak position of the emission are dependent on both oxidation state and ligand environment and the emission has been identified from the hemoglobin oligomer.

  9. Cell Surface Glycosylation Is Required for Efficient Mating of Haloferax volcanii

    Directory of Open Access Journals (Sweden)

    Yarden Shalev

    2017-07-01

    Full Text Available Halophilic archaea use a fusion-based mating system for lateral gene transfer across cells, yet the molecular mechanisms involved remain unknown. Previous work implied that cell fusion involves cell–cell recognition since fusion occurs more efficiently between cells from the same species. Long believed to be restricted only to Eukarya, it is now known that cells of all three domains of life perform N-glycosylation, the covalent attachment of glycans to select target asparagine residues in proteins, and that this post-translational modification is common for archaeal cell surface proteins. Here, we show that differences in glycosylation of the Haloferax volcanii surface-layer glycoprotein, brought about either by changing medium salinity or by knocking out key glycosylation genes, reduced mating success. Thus, different glycosylation patterns are likely to underlie mating preference in halophilic archaea, contributing to speciation processes.

  10. Radio-ligand immunoassay for human hemoglobin variants

    International Nuclear Information System (INIS)

    Javid, J.; Pettis, P.K.; Miller, J.E.

    1981-01-01

    A quantitative method is described for the individual assay of human hemoglobin variants occurring singly or in mixture. The hemoglobin to be assayed is bound to specific antibody; the immune complex is attached to protein A-containing S. aureus and removed from the mixture. The hemoglobin thus isolated is quantified by its ability to bind radiolabeled haptoglobin. The technique is accurate and distinguishes among the 4 hemoglobins tested, namely Hb A, S, C and F. It has the advantage over conventional radioimmunoassay that a single probe, radiolabeled haptoglobin, is needed for the specific assay of any hemoglobin. (Auth.)

  11. Non-invasive spectroscopy of transfusable red blood cells stored inside sealed plastic blood-bags.

    Science.gov (United States)

    Buckley, K; Atkins, C G; Chen, D; Schulze, H G; Devine, D V; Blades, M W; Turner, R F B

    2016-03-07

    After being separated from (donated) whole blood, red blood cells are suspended in specially formulated additive solutions and stored (at 4 °C) in polyvinyl chloride (PVC) blood-bags until they are needed for transfusion. With time, the prepared red cell concentrate (RCC) is known to undergo biochemical changes that lower effectiveness of the transfusion, and thus regulations are in place that limit the storage period to 42 days. At present, RCC is not subjected to analytical testing prior to transfusion. In this study, we use Spatially Offset Raman Spectroscopy (SORS) to probe, non-invasively, the biochemistry of RCC inside sealed blood-bags. The retrieved spectra compare well with conventional Raman spectra (of sampled aliquots) and are dominated by features associated with hemoglobin. In addition to the analytical demonstration that SORS can be used to retrieve RCC spectra from standard clinical blood-bags without breaking the sterility of the system, the data reveal interesting detail about the oxygenation-state of the stored cells themselves, namely that some blood-bags unexpectedly contain measurable amounts of deoxygenated hemoglobin after weeks of storage. The demonstration that chemical information can be obtained non-invasively using spectroscopy will enable new studies of RCC degeneration, and points the way to a Raman-based instrument for quality-control in a blood-bank or hospital setting.

  12. Insulin detemir for the treatment of obese patients with type 2 diabetes

    OpenAIRE

    Hollander, Priscilla A

    2012-01-01

    Priscilla A Hollander1,21Baylor Endocrine Center, 2Baylor Medical Center, Dallas, Texas, USAAbstract: The risk for developing type 2 diabetes (T2DM) is greater among obese individuals. Following onset of the disease, patients with T2DM become more likely to be afflicted with diabetic micro- and macrovascular complications. Decreasing body weight has been shown to lower glycosylated hemoglobin and improve other metabolic parameters in patients with T2DM. Medications used to lower blood glucose...

  13. 诺和锐30联合茵陈蒿汤加减方治疗慢性乙型肝炎合并糖尿病的疗效分析

    Directory of Open Access Journals (Sweden)

    LIU Hongxia

    2014-04-01

    Full Text Available ObjectiveTo investigate the treatment methods for chronic hepatitis B (CHB with diabetes. MethodsSixty-eight patients with CHB accompanied by diabetes who were hospitalized in the division of infectious diseases of our hospital from January 2008 to December 2012 were included in the study. These patients were divided into treatment group (n=41 and control group (n=27 based on treatment methods. In addition to conventional liver protection treatment, NovoRapid 30 was given to the control group, while NovoRapid 30 combined with modified Yinchenhao decoction were given to the treatment group. During treatment, liver function, blood glucose levels, and glycosylated hemoglobin levels were monitored periodically; liver function recovery time was analyzed statistically; the incidence of hypoglycemia for each patient and daily dose of insulin were recorded and analyzed statistically. Before-after comparison and between-group comparison of means were made by t test. ResultsAfter treatment, both groups showed a significant improvement in liver function (P<0.01 and significant decreases in blood glucose and glycosylated hemoglobin levels (P<0.01; the treatment group had a significantly lower glycosylated hemoglobin level than the control group (6.3%±0.6% vs 7.3%±0.5%, t=7.46, P<0.01. Compared with the control group, the treatment group had a significantly shorter liver function recovery time (28.7±5.61 days vs 35.5±6.33 days, t=4.53, P<0.01, a significantly lower incidence of hypoglycemia (0.8±0.3 times/patient vs 2.2±0.8 times/patient, t=8.78, P<0.01, and a significantly lower daily dose of insulin (37.4±5.2 U vs 44.6±6.5 U, t=4.86, P<0.01. ConclusionCombination therapy with NovoRapid and modified Yinchenhao decoction is an effective, safe, and economical approach to the treatment of CHB with diabetes

  14. A Novel Strategy for Characterization of Glycosylated Proteins Separated by Gel Electrophoresis

    DEFF Research Database (Denmark)

    Larsen, Martin; Skottrup, Peter; Enghild, Jan Johannes

    Protein glycosylation can be vital for changing the function or physiochemical properties of a protein. Abnormal glycosylation can lead to protein malfunction, resulting in severe diseases. Therefore, it is important to develop techniques for characterization of such modifications in proteins...... graphite powder micro-columns in combination with mass spectrometry. The method is faster and more sensitive than previous approaches and would be ideal for proteomics studies and verification of correct glycosylation of recombinant glycoproteins....

  15. Etiology of anemia of blood donor candidates deferred by hematologic screening

    Directory of Open Access Journals (Sweden)

    Michel Alves da Silva

    2012-01-01

    Full Text Available OBJECTIVE: Iron deficiency is the most common cause of anemia and one of the main factors in the clinical deferral of blood donors. This fact prompted the current study that aimed to determine the prevalence and etiology of anemia in blood donor candidates and to evaluate the hematological screening technique used for the exclusion of these donors. METHODS: This was a prospective study that compared two groups (Anemic and Non-anemic. Initially screening for anemia was performed by manually measuring hemoglobin (Bioclin® Kit; the results were subsequently compared with an automated screening method (Coulter T-890. The etiology was investigated by hemoglobin electrophoresis in alkaline and acid pH, Hb A2 dosage and measurement of the ferritin concentration by immunoagglutination. Differences and associations of interest were analyzed using the Yates and McNemar's Chi-square tests and the Fisher, Mann-Whitney, Wilcoxon and Kruskal-Wallis tests. RESULTS: The deferral rate due to anemia was 4.2%; iron deficiency was identified in 37.5% and beta thalassemia in 9.3% of the excluded candidates. There was a significant discrepancy between the two techniques used to measure hemoglobin with 38.1% of initially deferred donors presenting normal hemoglobin levels by the automated method. CONCLUSION: The results show a high rate of blood donors being deferred for anemia and confirm that iron deficiency is the most prevalent cause. The discrepancies found by comparing screening methods suggest that hemoglobin and hematocrit levels should be confirmed before deferring a donor due to anemia; this may increase supplies in blood banks.

  16. Relationship of Baseline Hemoglobin Level with Serum Ferritin, Postphlebotomy Hemoglobin Changes, and Phlebotomy Requirements among HFE C282Y Homozygotes

    Directory of Open Access Journals (Sweden)

    Seyed Ali Mousavi

    2015-01-01

    Full Text Available Objectives. We aimed to examine whether baseline hemoglobin levels in C282Y-homozygous patients are related to the degree of serum ferritin (SF elevation and whether patients with different baseline hemoglobin have different phlebotomy requirements. Methods. A total of 196 patients (124 males and 72 females who had undergone therapeutic phlebotomy and had SF and both pre- and posttreatment hemoglobin values were included in the study. Results. Bivariate correlation analysis suggested that baseline SF explains approximately 6 to 7% of the variation in baseline hemoglobin. The results also showed that males who had higher (≥150 g/L baseline hemoglobin levels had a significantly greater reduction in their posttreatment hemoglobin despite requiring fewer phlebotomies to achieve iron depletion than those who had lower (<150 g/L baseline hemoglobin, regardless of whether baseline SF was below or above 1000 µg/L. There were no significant differences between hemoglobin subgroups regarding baseline and treatment characteristics, except for transferrin saturation between male subgroups with SF above 1000 µg/L. Similar differences were observed when females with higher (≥138 g/L baseline hemoglobin were compared with those with lower (<138 g/L baseline hemoglobin. Conclusion. Dividing C282Y-homozygous patients into just two subgroups according to the degree of baseline SF elevation may obscure important subgroup variations.

  17. Relationship of Baseline Hemoglobin Level with Serum Ferritin, Postphlebotomy Hemoglobin Changes, and Phlebotomy Requirements among HFE C282Y Homozygotes

    Science.gov (United States)

    Mousavi, Seyed Ali; Mahmood, Faiza; Aandahl, Astrid; Knutsen, Teresa Risopatron; Llohn, Abid Hussain

    2015-01-01

    Objectives. We aimed to examine whether baseline hemoglobin levels in C282Y-homozygous patients are related to the degree of serum ferritin (SF) elevation and whether patients with different baseline hemoglobin have different phlebotomy requirements. Methods. A total of 196 patients (124 males and 72 females) who had undergone therapeutic phlebotomy and had SF and both pre- and posttreatment hemoglobin values were included in the study. Results. Bivariate correlation analysis suggested that baseline SF explains approximately 6 to 7% of the variation in baseline hemoglobin. The results also showed that males who had higher (≥150 g/L) baseline hemoglobin levels had a significantly greater reduction in their posttreatment hemoglobin despite requiring fewer phlebotomies to achieve iron depletion than those who had lower (baseline hemoglobin, regardless of whether baseline SF was below or above 1000 µg/L. There were no significant differences between hemoglobin subgroups regarding baseline and treatment characteristics, except for transferrin saturation between male subgroups with SF above 1000 µg/L. Similar differences were observed when females with higher (≥138 g/L) baseline hemoglobin were compared with those with lower (baseline hemoglobin. Conclusion. Dividing C282Y-homozygous patients into just two subgroups according to the degree of baseline SF elevation may obscure important subgroup variations. PMID:26380265

  18. Open Craniosynostosis Surgery: Effect of Early Intraoperative Blood Transfusion on Postoperative Course.

    Science.gov (United States)

    Kurnik, Nicole M; Bristol, Ruth; Maneri, Celia; Singhal, Raj; Singh, Davinder J

    2017-07-01

    Correction of craniosynostosis can result in blood loss when the patient already has physiologic anemia. The aim of this study was to determine whether patients benefit from early blood transfusion and whether the timing of blood transfusion affects metabolic disturbances and the postoperative course. In this retrospective review, 71 patients who underwent open calvarial vault remodeling for correction of craniosynostosis were separated into 2 groups according to whether they received blood transfusions early (within the first 30 minutes of surgery) or later (after the first 30 minutes of surgery). Patients were further separated into nonsyndromic and syndromic cohorts. Tracked variables included hemoglobin, hematocrit, arterial blood gas values, lactate level, length of stay, estimated blood loss, and amount of blood transfused in the operating room, amount transfused postoperatively, and total amount transfused.Among all patients, the early transfusion group had a higher hemoglobin nadir overall and received less postoperative blood. Within the nonsyndromic cohort, the early transfusion group had a higher estimated blood loss and received more transfused blood. In the syndromic cohort, the early transfusion group had a hemoglobin nadir that was significantly higher than in the late transfusion group and a lower estimated blood loss, shorter pediatric intensive care unit stay, and less postoperative blood transfused. Syndromic patients also received significantly more blood overall. For syndromic patients undergoing open calvarial vault remodeling, transfusion within the first 30 minutes of surgery should be considered.

  19. U-shaped curve for risk associated with maternal hemoglobin, iron status, or iron supplementation.

    Science.gov (United States)

    Dewey, Kathryn G; Oaks, Brietta M

    2017-12-01

    Both iron deficiency (ID) and excess can lead to impaired health status. There is substantial evidence of a U-shaped curve between the risk of adverse birth outcomes and maternal hemoglobin concentrations during pregnancy; however, it is unclear whether those relations are attributable to conditions of low and high iron status or to other mechanisms. We summarized current evidence from human studies regarding the association between birth outcomes and maternal hemoglobin concentrations or iron status. We also reviewed effects of iron supplementation on birth outcomes among women at low risk of ID and the potential mechanisms for adverse effects of high iron status during pregnancy. Overall, we confirmed a U-shaped curve for the risk of adverse birth outcomes with maternal hemoglobin concentrations, but the relations differ by trimester. For low hemoglobin concentrations, the link with adverse outcomes is more evident when hemoglobin concentrations are measured in early pregnancy. These relations generally became weaker or nonexistent when hemoglobin concentrations are measured in the second or third trimesters. Associations between high hemoglobin concentration and adverse birth outcomes are evident in all 3 trimesters but evidence is mixed. There is less evidence for the associations between maternal iron status and adverse birth outcomes. Most studies used serum ferritin (SF) concentrations as the indicator of iron status, which makes the interpretation of results challenging because SF concentrations increase in response to inflammation or infection. The effect of iron supplementation during pregnancy may depend on initial iron status. There are several mechanisms through which high iron status during pregnancy may have adverse effects on birth outcomes, including oxidative stress, increased blood viscosity, and impaired systemic response to inflammation and infection. Research is needed to understand the biological processes that underlie the U-shaped curves

  20. HEK293T cell lines defective for O-linked glycosylation.

    Directory of Open Access Journals (Sweden)

    James M Termini

    Full Text Available Here we describe derivatives of the HEK293T cell line that are defective in their ability to generate mucin-type O-linked glycosylation. Using CRISPR/Cas9 and a single-cell GFP-sorting procedure, the UDP-galactose-4-epimerase (GALE, galactokinase 1 (GALK1, and galactokinase 2 (GALK2 genes were knocked out individually and in combinations with greater than 90% of recovered clones having the desired mutations. Although HEK293T cells are tetraploid, we found this approach to be an efficient method to target and disrupt all 4 copies of the target gene. Deficient glycosylation in the GALE knockout cell line could be rescued by the addition of galactose and N-acetylgalactosamine (GalNAc to the cell culture media. However, when key enzymes of the galactose/GalNAc salvage pathways were disrupted in tandem (GALE+GALK1 or GALE+GALK2, O-glycosylation was eliminated and could not be rescued by the addition of either galactose plus GalNAc or UDP-galactose plus UDP-GalNAc. GALK1 and GALK2 are key enzymes of the galactose/GalNAc salvage pathways. Mass spectrometry was performed on whole cell lysate of the knockout cell lines to verify the glycosylation phenotype. As expected, the GALE knockout was almost completely devoid of all O-glycosylation, with minimal glycosylation as a result of functional salvage pathways. However, the GALE+GALK1 and GALE+GALK2 knockout lines were devoid of all O-glycans. Mass spectrometry analysis revealed that the disruption of GALE, GALK1, and GALE+GALK2 had little effect on the N-glycome. But when GALE was knocked out in tandem with GALK1, N-glycans were exclusively of the high mannose type. Due to the well-characterized nature of these five knockout cell lines, they will likely prove useful for a wide variety of applications.

  1. Nitric oxide formation from the reaction of nitrite with carp and rabbit hemoglobin at intermediate oxygen saturations

    DEFF Research Database (Denmark)

    Jensen, Frank Bo

    2008-01-01

    The nitrite reductase activity of deoxyhemoglobin has received much recent interest because the nitric oxide produced in this reaction may participate in blood flow regulation during hypoxia. The present study used spectral deconvolution to characterize the reaction of nitrite with carp and rabbit...... hemoglobin at different constant oxygen tensions that generate the full range of physiological relevant oxygen saturations. Carp is a hypoxia-tolerant species with very high hemoglobin oxygen affinity, and the high R-state character and low redox potential of the hemoglobin is hypothesized to promote...... NO generation from nitrite. The reaction of nitrite with deoxyhemoglobin leads to a 1 : 1 formation of nitrosylhemoglobin and methemoglobin in both species. At intermediate oxygen saturations, the reaction with deoxyhemoglobin is clearly favored over that with oxyhemoglobin, and the oxyhemoglobin reaction...

  2. Chemical changes in the blood of leukemia patients

    International Nuclear Information System (INIS)

    Iqbal, Y.; Shah, S.; Khan, S.A.; Khan, M.S.

    2007-01-01

    Blood samples of 10 patients of blood cancer were collected from Combined Military Hospital (CMH), Rawalpindi. These samples of leukemia patients before and after treatments were analyzed for hemoglobin, creatinine, urea, glucose, uric acid, bilirubin, protein, sodium, and potassium using different methods. The mean values for various tested parameters were found to be 8.8 m.mol/L (urea), 214.9 Jimol/L (creatinine), 7.4 m. mol/L (glucose), 40.2 g/L (albumin), 410.2 micro mol/L (uric acid), 24.6 micro mol/L (bilirubin), 138.2 m.mol/L (sodium), 5.04 m.mol/L (potassium) and 9.6 g/dL (hemoglobin). The data revealed that levels of glucose and sodium were within the normal range in all patients whereas blood spectrum for hemoglobin, creatinine, urea, uric acid, bilirubin and potassium showed abnormal results. The results predict that leukemia in the body lead to appreciable and detectable changes in the chemical profile of blood. Some of these changes are mainly caused because of the disease only while others may be due to the disease as well as the treatment phenomenon i.e. effect of medicines. The findings thus obtained provide useful information to the researchers and the specialist doctors of the disease. (author)

  3. Glycosylation patterns of kidney proteins differ in rat diabetic nephropathy.

    Science.gov (United States)

    Ravidà, Alessandra; Musante, Luca; Kreivi, Marjut; Miinalainen, Ilkka; Byrne, Barry; Saraswat, Mayank; Henry, Michael; Meleady, Paula; Clynes, Martin; Holthofer, Harry

    2015-05-01

    Diabetic nephropathy often progresses to end-stage kidney disease and, ultimately, to renal replacement therapy. Hyperglycemia per se is expected to have a direct impact on the biosynthesis of N- and O-linked glycoproteins. This study aims to establish the link between protein glycosylation and progression of experimental diabetic kidney disease using orthogonal methods. Kidneys of streptozotocin-diabetic and control rats were harvested at three different time points post streptozotocin injection. A panel of 12 plant lectins was used in the screening of lectin blots. The lectins UEAI, PHA-E, GSI, PNA, and RCA identified remarkable disease-associated differences in glycoprotein expression. Lectin affinity chromatography followed by mass spectrometric analyses led to the identification of several glycoproteins involved in salt-handling, angiogenesis, and extracellular matrix degradation. Our data confirm a substantial link between glycosylation signature and diabetes progression. Furthermore, as suggested by our findings on dipeptidyl peptidase-IV, altered protein glycosylation may reflect changes in biochemical properties such as enzymatic activity. Thus, our study demonstrates the unexplored potential of protein glycosylation analysis in the discovery of molecules linked to diabetic kidney disease.

  4. A review of variant hemoglobins interfering with hemoglobin A1c measurement.

    Science.gov (United States)

    Little, Randie R; Roberts, William L

    2009-05-01

    Hemoglobin A1c (HbA1c) is used routinely to monitor long-term glycemic control in people with diabetes mellitus, as HbA1c is related directly to risks for diabetic complications. The accuracy of HbA1c methods can be affected adversely by the presence of hemoglobin (Hb) variants or elevated levels of fetal hemoglobin (HbF). The effect of each variant or elevated HbF must be examined with each specific method. The most common Hb variants worldwide are HbS, HbE, HbC, and HbD. All of these Hb variants have single amino acid substitutions in the Hb beta chain. HbF is the major hemoglobin during intrauterine life; by the end of the first year, HbF falls to values close to adult levels of approximately 1%. However, elevated HbF levels can occur in certain pathologic conditions or with hereditary persistence of fetal hemoglobin. In a series of publications over the past several years, the effects of these four most common Hb variants and elevated HbF have been described. There are clinically significant interferences with some methods for each of these variants. A summary is given showing which methods are affected by the presence of the heterozygous variants S, E, C, and D and elevated HbF. Methods are divided by type (immunoassay, ion-exchange high-performance liquid chromatography, boronate affinity, other) with an indication of whether the result is artificially increased or decreased by the presence of a Hb variant. Laboratorians should be aware of the limitations of their method with respect to these interferences. 2009 Diabetes Technology Society.

  5. Model-based analysis of N-glycosylation in Chinese hamster ovary cells

    DEFF Research Database (Denmark)

    Krambeck, Frederick J.; Bennun, Sandra V; Andersen, Mikael Rørdam

    2017-01-01

    The Chinese hamster ovary (CHO) cell is the gold standard for manufacturing of glycosylated recombinant proteins for production of biotherapeutics. The similarity of its glycosylation patterns to the human versions enable the products of this cell line favorable pharmacokinetic properties and lower...

  6. Oxytocin analogues with O-glycosylated serine and threonine in position 4

    Czech Academy of Sciences Publication Activity Database

    Marcinkowska, A.; Borovičková, Lenka; Slaninová, Jiřina; Grzonka, Z.

    2007-01-01

    Roč. 81, č. 7 (2007), s. 1335-1344 ISSN 0137- 5083 Institutional research plan: CEZ:AV0Z40550506; CEZ:AV0Z90210515 Keywords : oxytocin * glycosylated serin * glycosylated threonin * position 4 Subject RIV: CE - Biochemistry Impact factor: 0.483, year: 2007

  7. Remission and regression in the nephropathy of type 1 diabetes when blood pressure is controlled aggressively

    DEFF Research Database (Denmark)

    Hovind, P; Rossing, P; Tarnow, L

    2001-01-01

    BACKGROUND: Diabetic nephropathy is a chronic, progressive kidney disease with a mean rate of decline of in glomerular filtration rate (GFR) of 10 to 12 mL/min/year (natural history). The introduction of aggressive antihypertensive treatment has improved the renal prognosis during the last decades...... pressure, albuminuria, glycosylated hemoglobin A1c, and serum cholesterol were measured every three to four months during the study. In total, 271 patients received antihypertensive treatment, 179 patients predominantly with angiotensin-converting enzyme inhibitors. Remission was defined as albuminuria...

  8. Development and validation of a noncontact spectroscopic device for hemoglobin estimation at point-of-care

    Science.gov (United States)

    Sarkar, Probir Kumar; Pal, Sanchari; Polley, Nabarun; Aich, Rajarshi; Adhikari, Aniruddha; Halder, Animesh; Chakrabarti, Subhananda; Chakrabarti, Prantar; Pal, Samir Kumar

    2017-05-01

    Anemia severely and adversely affects human health and socioeconomic development. Measuring hemoglobin with the minimal involvement of human and financial resources has always been challenging. We describe a translational spectroscopic technique for noncontact hemoglobin measurement at low-resource point-of-care settings in human subjects, independent of their skin color, age, and sex, by measuring the optical spectrum of the blood flowing in the vascular bed of the bulbar conjunctiva. We developed software on the LabVIEW platform for automatic data acquisition and interpretation by nonexperts. The device is calibrated by comparing the differential absorbance of light of wavelength 576 and 600 nm with the clinical hemoglobin level of the subject. Our proposed method is consistent with the results obtained using the current gold standard, the automated hematology analyzer. The proposed noncontact optical device for hemoglobin estimation is highly efficient, inexpensive, feasible, and extremely useful in low-resource point-of-care settings. The device output correlates with the different degrees of anemia with absolute and trending accuracy similar to those of widely used invasive methods. Moreover, the device can instantaneously transmit the generated report to a medical expert through e-mail, text messaging, or mobile apps.

  9. Micropinocytic ingestion of glycosylated albumin by isolated microvessels: possible role in pathogenesis of diabetic microangiopathy.

    OpenAIRE

    Williams, S K; Devenny, J J; Bitensky, M W

    1981-01-01

    Microvessels isolated from rat epididymal fat exhibit differential vesicular ingestion rates for unmodified and non-enzymatically glycosylated rat albumin. While unmodified rat albumin is excluded from ingestion by endothelial micropinocytic vesicles, glycosylated albumin is avidly taken up by endocytosis. Interaction of albumin and glycosylated albumin with endothelium was studied with a double-label fluorescence assay of micropinocytosis. When glycosylated albumin was present at a concentra...

  10. Demographic details, clinical features, and nutritional characteristics of young adults with Type 1 diabetes mellitus - A South Indian tertiary center experience.

    Science.gov (United States)

    Joseph, Mini; Shyamasunder, Asha H; Gupta, Riddhi D; Anand, Vijayalakshmi; Thomas, Nihal

    2016-01-01

    Type 1 diabetes mellitus (T1DM) accounts for 5-10% of all diagnosed diabetes and the highest incidence is found in India. The main objectives were to study the demographic, clinical, and nutritional characteristics of young adults with T1DM and its effect glycosylated hemoglobin levels. This cross-sectional study was conducted among young adults with T1DM (18-45 years of age) in a tertiary hospital in South India. Data were obtained from updated medical records. The dietary data were assessed from food diaries and 24 h recall method. Anthropometry was determined. The analysis revealed that socio-economic variables did not affect the glycosylated hemoglobin levels. The mean glycosylated hemoglobin value was 8.81 ± 2.38%. Nearly, half the patients were malnourished. The overall dietary intake was inadequate. The multivariate regression model, adjusted for confounding factors such as gender, age, and body mass index, revealed that only duration of diabetes and protein intake were significant predictors of glycosylated hemoglobin status ( P diabetes management. However, there is an urgent need to educate our patients on nutrition therapy. T1DM patients need specialized advice to ensure appropriately balanced nutrition that has a significant impact on their long-term glycemic control.

  11. Fetal hemoglobin is much less prone to DNA cleavage compared to the adult protein

    Directory of Open Access Journals (Sweden)

    Sandeep Chakane

    2017-08-01

    Full Text Available Hemoglobin (Hb is well protected inside the red blood cells (RBCs. Upon hemolysis and when free in circulation, Hb can be involved in a range of radical generating reactions and may thereby attack several different biomolecules. In this study, we have examined the potential damaging effects of cell-free Hb on plasmid DNA (pDNA. Hb induced cleavage of supercoiled pDNA (sc pDNA which was proportional to the concentration of Hb applied. Almost 70% of sc pDNA was converted to open circular or linear DNA using 10 µM of Hb in 12 h. Hb can be present in several different forms. The oxy (HbO2 and met forms are most reactive, while the carboxy-protein shows only low hydrolytic activity. Hemoglobin A (HbA could easily induce complete pDNA cleavage while fetal hemoglobin (HbF was three-fold less reactive. By inserting, a redox active cysteine residue on the surface of the alpha chain of HbF by site-directed mutagenesis, the DNA cleavage reaction was enhanced by 82%. Reactive oxygen species were not directly involved in the reaction since addition of superoxide dismutase and catalase did not prevent pDNA cleavage. The reactivity of Hb with pDNA can rather be associated with the formation of protein based radicals. Keywords: Adult hemoglobin, Fetal hemoglobin, Supercoiled plasmid DNA, DNA cleavage, Cysteine, Protein radicals

  12. Monitor hemoglobin concentration and oxygen saturation in living mouse tail using photoacoustic CT scanner

    Science.gov (United States)

    Liu, Bo; Kruger, Robert; Reinecke, Daniel; Stantz, Keith M.

    2010-02-01

    Purpose: The purpose of this study is to use PCT spectroscopy scanner to monitor the hemoglobin concentration and oxygen saturation change of living mouse by imaging the artery and veins in a mouse tail. Materials and Methods: One mouse tail was scanned using the PCT small animal scanner at the isosbestic wavelength (796nm) to obtain its hemoglobin concentration. Immediately after the scan, the mouse was euthanized and its blood was extracted from the heart. The true hemoglobin concentration was measured using a co-oximeter. Reconstruction correction algorithm to compensate the acoustic signal loss due to the existence of bone structure in the mouse tail was developed. After the correction, the hemoglobin concentration was calculated from the PCT images and compared with co-oximeter result. Next, one mouse were immobilized in the PCT scanner. Gas with different concentrations of oxygen was given to mouse to change the oxygen saturation. PCT tail vessel spectroscopy scans were performed 15 minutes after the introduction of gas. The oxygen saturation values were then calculated to monitor the oxygen saturation change of mouse. Results: The systematic error for hemoglobin concentration measurement was less than 5% based on preliminary analysis. Same correction technique was used for oxygen saturation calculation. After correction, the oxygen saturation level change matches the oxygen volume ratio change of the introduced gas. Conclusion: This living mouse tail experiment has shown that NIR PCT-spectroscopy can be used to monitor the oxygen saturation status in living small animals.

  13. N-glycosylated catalytic unit meets O-glycosylated propeptide: complex protein architecture in a fungal hexosaminidase

    Czech Academy of Sciences Publication Activity Database

    Plíhal, Ondřej; Sklenář, Jan; Kmoníčková, J.; Man, Petr; Pompach, Petr; Havlíček, Vladimír; Křen, Vladimír; Bezouška, Karel

    2004-01-01

    Roč. 32, č. 5 (2004), s. 764-765 ISSN 0300-5127 R&D Projects: GA ČR GA203/04/1045 Institutional research plan: CEZ:AV0Z5020903 Keywords : asperillus oryzoe * glycosyl hydrolase * preproprotein Subject RIV: EE - Microbiology, Virology Impact factor: 2.267, year: 2004

  14. Direct sGC activation bypasses no scavenging reactions of intravascular free oxy-hemoglobin and limits vasoconstriction

    NARCIS (Netherlands)

    N.J.H. Raat (Nicolaas); D.M. Tabima (D. Marcela); P. Specht (Patricia); J. Tejero (Jesús); M.P. Champion (Michael); D.B. Kim-Shapiro (Daniel); J.G. Baust (John ); E.G. Mik (Egbert); M. Hildesheim (Mariana); J.-P. Stasch (Johannes-Peter); E.-M. Becker (Eva-Maria); H. Truebel (Hubert); M.T. Gladwin (Mark)

    2013-01-01

    textabstractAims: Hemoglobin-based oxygen carriers (HBOC) provide a potential alternative to red blood cell (RBC) transfusion. Their clinical application has been limited by adverse effects, in large part thought to be mediated by the intravascular scavenging of the vasodilator nitric oxide (NO) by

  15. Erythrocyte enrichment in hematopoietic progenitor cell cultures based on magnetic susceptibility of the hemoglobin.

    Directory of Open Access Journals (Sweden)

    Xiaoxia Jin

    Full Text Available Using novel media formulations, it has been demonstrated that human placenta and umbilical cord blood-derived CD34+ cells can be expanded and differentiated into erythroid cells with high efficiency. However, obtaining mature and functional erythrocytes from the immature cell cultures with high purity and in an efficient manner remains a significant challenge. A distinguishing feature of a reticulocyte and maturing erythrocyte is the increasing concentration of hemoglobin and decreasing cell volume that results in increased cell magnetophoretic mobility (MM when exposed to high magnetic fields and gradients, under anoxic conditions. Taking advantage of these initial observations, we studied a noninvasive (label-free magnetic separation and analysis process to enrich and identify cultured functional erythrocytes. In addition to the magnetic cell separation and cell motion analysis in the magnetic field, the cell cultures were characterized for cell sedimentation rate, cell volume distributions using differential interference microscopy, immunophenotyping (glycophorin A, hemoglobin concentration and shear-induced deformability (elongation index, EI, by ektacytometry to test for mature erythrocyte attributes. A commercial, packed column high-gradient magnetic separator (HGMS was used for magnetic separation. The magnetically enriched fraction comprised 80% of the maturing cells (predominantly reticulocytes that showed near 70% overlap of EI with the reference cord blood-derived RBC and over 50% overlap with the adult donor RBCs. The results demonstrate feasibility of label-free magnetic enrichment of erythrocyte fraction of CD34+ progenitor-derived cultures based on the presence of paramagnetic hemoglobin in the maturing erythrocytes.

  16. Effects of delayed cord clamping on residual placental blood volume, hemoglobin and bilirubin levels in term infants: a randomized controlled trial.

    Science.gov (United States)

    Mercer, J S; Erickson-Owens, D A; Collins, J; Barcelos, M O; Parker, A B; Padbury, J F

    2017-03-01

    The objective of the study was to measure the effects of a 5-min delay (DCC) versus immediate cord clamping (ICC) on residual placental blood volume (RPBV) at birth, and hemoglobin and serum bilirubin at 24 to 48 h of age. In this prospective randomized controlled trial, 73 women with term (37 to 41 weeks) singleton fetuses were randomized to DCC (⩾5 min; n=37) or ICC (protocol violations. Cord milking was the proxy for DCC (n=11) when the provider could not wait. Infants randomized to DCC compared with ICC had significantly less RPBV (20.0 versus 30.8 ml kg -1 , Phemoglobin levels (19.4 versus 17.8 g dl -1 , P=0.002) at 24 to 48 h, with no difference in bilirubin levels. Term infants had early hematological advantage of DCC without increases in hyperbilirubinemia or symptomatic polycythemia.

  17. Characterization of hemoglobin-benzo[a]pyrene adducts

    International Nuclear Information System (INIS)

    Haugen, D.A.; Myers, S.R.

    1987-01-01

    Cultures of Syrian hamster embryo (SHE) cells were supplemented with human Hb (0.2 mM heme) and [ 3 H]BP (1 μM). After a 24-h incubation, the medium was removed and subjected to cation-exchange liquid chromatography (CM-Sepharose) to resolve hemoglobins from serum proteins in the medium. The BP-treated Hb was subjected to analysis in each of three column chromatographic systems established for isolation and characterization of human hemoglobin and its genetic and post-translationally modified variants. Results demonstrate that hemoglobin-carcinogen adducts can be resolved from native hemoglobin by established conventional and high-performance liquid chromatographic procedures, suggesting the basis for development of general approaches for isolating and characterizing hemoglobin-carcinogen adducts. The results also suggest the basis for a model system in which adducts between carcinogens and human hemoglobin are formed in cultures of mammalian cells or tissues

  18. In-depth mapping of the mouse brain N-glycoproteome reveals widespread N-glycosylation of diverse brain proteins.

    Science.gov (United States)

    Fang, Pan; Wang, Xin-Jian; Xue, Yu; Liu, Ming-Qi; Zeng, Wen-Feng; Zhang, Yang; Zhang, Lei; Gao, Xing; Yan, Guo-Quan; Yao, Jun; Shen, Hua-Li; Yang, Peng-Yuan

    2016-06-21

    N-glycosylation is one of the most prominent and abundant posttranslational modifications of proteins. It is estimated that over 50% of mammalian proteins undergo glycosylation. However, the analysis of N-glycoproteins has been limited by the available analytical technology. In this study, we comprehensively mapped the N-glycosylation sites in the mouse brain proteome by combining complementary methods, which included seven protease treatments, four enrichment techniques and two fractionation strategies. Altogether, 13492 N-glycopeptides containing 8386 N-glycosylation sites on 3982 proteins were identified. After evaluating the performance of the above methods, we proposed a simple and efficient workflow for large-scale N-glycosylation site mapping. The optimized workflow yielded 80% of the initially identified N-glycosylation sites with considerably less effort. Analysis of the identified N-glycoproteins revealed that many of the mouse brain proteins are N-glycosylated, including those proteins in critical pathways for nervous system development and neurological disease. Additionally, several important biomarkers of various diseases were found to be N-glycosylated. These data confirm that N-glycosylation is important in both physiological and pathological processes in the brain, and provide useful details about numerous N-glycosylation sites in brain proteins.

  19. Synergistic Effect of Sodium Butyrate and Thalidomide in the Induction of Fetal Hemoglobin Expression in Erythroid Progenitors Derived from Cord Blood CD133 + Cells

    Directory of Open Access Journals (Sweden)

    Ali Dehghanifard

    2012-07-01

    Full Text Available Background: The use of drugs with the ability to induce production of fetal hemoglobin as a novel therapeutic approach in treating β-Hemoglobinopathies is considered. γ-globin gene expression inducer drugs including sodium butyrate and thalidomide can reduce additional α-globin chains accumulation in erythroid precursors. Materials and Methods: In this experimental study, MACS kit was used to isolate CD133+ cells of umbilical cord blood. Further, the effect of two drugs of thalidomide and sodium butyrate were separately and combined studied on the induction of quantitative expression of β-globin and γ-globin genes in erythroid precursor cells derived from CD133+ stem cells in-vitro. For this purpose, the technique SYBR green Real-time PCR was used.Results: Flow cytometry results showed that approximately 95% of purified cells were CD133+. Real-time PCR results also showed the increased levels of γ-globin mRNA in the cell groups treated with thalidomide, sodium butyrate and combination of drugs as 2.6 and 1.2 and 3.5 times respectively, and for β-globin gene, it is respectively 1.4 and 1.3 and 1.6 times compared with the control group (p<0.05.Conclusion: The study results showed that the mentioned drug combination can act as a pharmaceutical composition affecting the induction of fetal hemoglobin expression in erythroid precursor cells derived from CD133 + cells.

  20. Fab glycosylation of immunoglobulin G does not associate with improvement of rheumatoid arthritis during pregnancy.

    Science.gov (United States)

    Bondt, Albert; Wuhrer, Manfred; Kuijper, T Martijn; Hazes, Johanna M W; Dolhain, Radboud J E M

    2016-11-25

    Changes in immunoglobulin G (IgG) constant domain (Fc) glycosylation are associated with changes in rheumatoid arthritis (RA) disease activity in response to pregnancy. Here, we sought to determine whether the same holds true for variable domain (Fab) glycosylation. IgGs were captured from RA and control sera obtained before (RA only), during and after pregnancy, followed by Fc and Fab separation, glycan release, and mass spectrometric detection. In parallel, glycans from intact IgG were analysed. The data was used to calculate glycosylation traits, and to estimate the level of Fab glycosylation. The overall level of Fab glycosylation was increased in RA patients compared to controls, while no differences in Fab glycosylation patterns were found. For the Fc and intact IgG (Total) previously observed differences in galactosylation and bisection were confirmed. Furthermore, increased galactosylation of Fc and Total were associated with lower disease activity and autoantibody positivity. In addition, the change in Fc galactosylation associated with the change in disease activity during pregnancy and after delivery, while this was not the case for Fab. In contrast to changes in Fc glycosylation, changes in Fab glycosylation are not associated with improvement of RA during pregnancy and arthritis flare after delivery.

  1. The variation profile of blood components indicates the degree of severity in psoriasis as inflammatory disease

    International Nuclear Information System (INIS)

    Mahesar, S.M.; Dahot, M.U.

    2010-01-01

    To evaluate the changes occurring in blood cells and hemoglobin concentration in 158 subjects recruited. For the study comprised (44) psoriatic males and (35) psoriatic females. The blood sample analyses, microscopically. White blood cells shows higher count while neutrophils and lymphocytes showed a marked enhancement in psoriatic samples. Erythrocyte sedimentation rate was measured by Western Green method. ESR in psoriatic male patients mean 31+-10 hgmm/hr opposed to 9.5+-4.1 hgmm/hr in healthy males and in female psoriatic patients mean 34+-12 hgmm/hr against 15+-3 hgmm/hr healthy females was noted. Elevation of erythrocyte sedimentation rate was observed in psoriatic patients. The mean hemoglobin level (cyanide method) in psoriatic male was 12+-1.2 g/dl opposed to 15.2+-1.3 g/dl in healthy males while in psoriatic females it was 11.1+-1.4 g/dl as opposed to 14+-1.6 g/dl in healthy females. Hemoglobin shows reduced concentration in psoriatic patients. The marked changes in white blood sells, Erythrocyte sedimentation rate and hemoglobin concentration indicates psoriasis as inflammatory disease. (author)

  2. Analysis of expression and glycosylation of avian metapneumovirus attachment glycoprotein from recombinant baculoviruses.

    Science.gov (United States)

    Luo, Lizhong; Nishi, Krista; MacLeod, Erin; Sabara, Marta I; Li, Yan

    2010-11-01

    Recently, we reported the expression and glycosylation of avian metapneumovirus attachment glycoprotein (AMPV/C G protein) in eukaryotic cell lines by a transient-expression method. In the present study, we investigated the biosynthesis and O-linked glycosylation of the AMPV/C G protein in a baculovirus expression system. The results showed that the insect cell-produced G protein migrated more rapidly in SDS-PAGE as compared to LLC-MK2 cell-derived G proteins owing to glycosylation differences. The fully processed, mature form of G protein migrated between 78 and 86 kDa, which is smaller than the 110 kDa mature form of G expressed in LLC-MK2 cells. In addition, several immature G gene products migrating at 40-48 and 60-70 kDa were also detected by SDS-PAGE and represented glycosylated intermediates. The addition of the antibiotic tunicamycin, which blocks early steps of glycosylation, to insect cell culture resulted in the disappearance of two glycosylated forms of the G protein and identified a 38 kDa unglycosylated precursor. The maturation of the G protein was completely blocked by monensin, suggesting that the O-linked glycosylation of G initiated in the trans-Golgi compartment. The presence of O-linked sugars on the mature protein was further confirmed by lectin Arachis hypogaea binding assay. Furthermore, antigenic features of the G protein expressed in insect cells were evaluated by ELISA. Crown Copyright © 2010. Published by Elsevier B.V. All rights reserved.

  3. Experts: hospitals can improve care, save health care dollars by cracking down on unnecessary blood transfusions.

    Science.gov (United States)

    2013-01-01

    Leading health care quality organizations say that blood transfusions are among the most overused treatments. The problem wastes a precious resource as well as health care dollars, continues to stretch what is known to be in short supply in some parts of the country. Part of the problem is continued adherence to an outdated medical practice that calls for transfusions when they are not medically necessary. Also, experts say many guidelines are vague regarding hemoglobin triggers. However, education coupled with IT-driven interventions can help hospitals make dramatic improvements in their blood usage, potentially preserving blood products for patients who really need them. The American Red Cross says that blood use rose by 40% in the United States between 1994 and 2008. Studies show there is wide variation regarding when blood transfusions are called for by practitioners. The latest research suggests hemoglobin thresholds of 7 or 8 grams per deciliter are acceptable, although practitioners often call for transfusions when hemoglobin is at 10 grams per deciliter. Of particular importance to EDs, the lower hemoglobin triggers don't always apply to actively bleeding patients. Through a comprehensive blood conservation program, Eastern Maine Medical Center in Bangor, ME, has been able to nearly halve the number of patients who now receive transfusions without negatively impacting patient care. Also, the program has saved the hospital more than $5 million in blood costs.

  4. N-Glycosylation optimization of recombinant antibodies in CHO cell through process and metabolic engineering

    DEFF Research Database (Denmark)

    Fan, Yuzhou

    , analysis, control and optimization of N-glycosylation were thoroughly reviewed. In particular, how to control and optimize N-glycosylation in CHO cells was exclusively studied. The main focus of this PhD project is to find effective approaches of modulating N-glycosylation of CHO-derived recombinant...... galactose as feed additives, changing process parameters such as seeding density and cultivation duration are all demonstrated to be effective. The causal explanation of their impact on glycosylation can be various, including product, metabolism, proteome and physiology-associated mechanism. In the middle...... part of the thesis, both literature reviews and experimental applications were provided to demonstrate how to use omics data and implement systems biology to understand biological activities, especially N-glycosylation in CHO cells. In the last part of the thesis, the second strategy that apply genetic...

  5. [The influence of nettle and burdock extracts in combination with different diets on dyslipidemia in diabetes mellitus model].

    Science.gov (United States)

    Vengerovsky, A I; Yakimova, T V; Nasanova, O N

    2015-01-01

    The influence of low-fat diet, nettle (Urtica dioica) leafs and burdock (Arctium lappa) roots extracts on lipid metabolism and glycosylation reactions has been investigated in experimental diabetes mellitus. These extracts were applied in diets with both high and low fat content. The experiments were performed on 90 noninbred male albino rats (200–220 g) that were divided into 9 experimental groups. Diabetes mellitus was modeled with twice-repeated intraperitoneal streptozotocin (30 mg/kg) injections. The animals received food with increased fat content (proteins – 8%, fats – 30%, carbohydrates – 62% of total daily caloric content) during 4 weeks before streptozotocine injections and 8 weeks after its discontinuation. Simultaneously the rats were daily administered nettle leafs (100 mg/kg), burdock roots (25 mg/kg) extracts or metformin (100 mg/kg) into the stomach during 10 days. During the period of agents introduction half the animals continued to receive food with high fat content, the other half received low fat diet (proteins – 20%, fats – 8%, carbohydrates – 72% of the total daily caloric content). The forth (control) group received low fat food only without extracts or metformin administration. The levels of blood glucose, glycosylated hemoglobin, malonic dialdehyde, lipid and lipoprotein fractions content were measured. It has been shown that after streptozotocine injections and 30% fat diet consumption the blood glucose level increased by 5.3 fold compared to that of the intact animals, the content of atherogenic lipid fractions increased by 2–8.3 fold and the protein glycosylation reactions were intensified by 1.9–2.5 fold. In animals fed with 8% fat diet the blood glucose and malonic dialdehyde content decreased by 1.8–2.3 fold. In this experiment the levels of triglycerides, total cholesterol, cholesterol of nonhigh-density lipoproteins, low-density and very low-density lipoproteins, as well as the cholesterol and protein content of

  6. Extreme Anemia (Hemoglobin 1.8 g/dL Secondary to Abnormal Uterine Bleeding

    Directory of Open Access Journals (Sweden)

    Ketaki Panse

    2017-01-01

    Full Text Available We present the case of a 39-year-old G5P5 woman who presented to the emergency department with complaints of shortness of breath, lightheadedness, and excessive uterine bleeding for 14 days, with a heart rate of 123 and a blood pressure of 137/65. Menses had been heavy for several months. A hemoglobin of 1.8 g/dL was discovered. An ultrasound revealed an 11.8 cm fibroid uterus, and the patient was transfused with 6 units of blood and placed on oral contraceptive pills.

  7. In vivo detection of hemoglobin oxygen saturation and carboxyhemoglobin saturation with multiwavelength photoacoustic microscopy.

    Science.gov (United States)

    Chen, Zhongjiang; Yang, Sihua; Xing, Da

    2012-08-15

    A method for noninvasively detecting hemoglobin oxygen saturation (SO2) and carboxyhemoglobin saturation (SCO) in subcutaneous microvasculature with multiwavelength photoacoustic microscopy is presented. Blood samples mixed with different concentrations of carboxyhemoglobin were used to test the feasibility and accuracy of photoacoustic microscopy compared with the blood-gas analyzer. Moreover, fixed-point detection of SO2 and SCO in mouse ear was obtained, and the changes from normoxia to carbon monoxide hypoxia were dynamically monitored in vivo. Experimental results demonstrate that multiwavelength photoacoustic microscopy can detect SO2 and SCO, which has future potential clinical applications.

  8. Enzymatic glycosylation of multivalent scaffolds

    Czech Academy of Sciences Publication Activity Database

    Bojarová, Pavla; Rosencrantz, R. R.; Elling, L.; Křen, Vladimír

    2013-01-01

    Roč. 42, č. 11 (2013), s. 4774-4797 ISSN 0306-0012 R&D Projects: GA MŠk(CZ) LD13042; GA ČR GAP207/10/0321 Institutional support: RVO:61388971 Keywords : N-ACETYLGLUCOSAMINYLTRANSFERASE-III * MUCIN TANDEM REPEAT * NEIGHBORING RESIDUE GLYCOSYLATION Subject RIV: CC - Organic Chemistry Impact factor: 30.425, year: 2013

  9. Hemoglobin of mice with radiation-induced mutations at the hemoglobin loci

    Energy Technology Data Exchange (ETDEWEB)

    Popp, R A; Stratton, L P; Hawley, D K; Effron, K [Oak Ridge National Lab., TN (USA)

    1979-01-15

    Chemical analyses were done on the abnormal hemoglobins of the five (101 x SEC)F/sub 1/ offspring of X- irradiated adult SEC mice to determine which hemoglobin genes were expressed in each hemoglobin variant. Three offspring of irradiated SEC males did not express either of the two kinds of ..cap alpha..-chains normally found in all SEC mice. The deficient ..cap alpha..-chain synthesis caused these mice to exhibit an ..cap alpha..-thalassemia similar to human ..cap alpha..-thalassemia. Scanning electron microscopy was used to show that many erythrocytes of mice with ..cap alpha..-thalassemia have bizarre shapes; e.g. many erythrocytes appeared flattened or had thorny projections (acanthocytes). One mutant with a tandem duplication of a segment of chromosome 7 (site of locus determining ..beta..-chain structure) produced twice as much SEC as 101 ..beta..-chain polypeptides. One mutant that probably arose by non-disjunction of chromosome 7's in its unirradiated 101 mother and loss of chromosome 7 from the gamete of its irradiated SEC father did not express the SEC ..beta..-chain gene.

  10. Hemoglobin of mice with radiation-induced mutations at the hemoglobin loci

    International Nuclear Information System (INIS)

    Popp, R.A.; Stratton, L.P.; Hawley, D.K.; Effron, K.

    1979-01-01

    Chemical analyses were done on the abnormal hemoglobins of the five (101 x SEC)F 1 offspring of X- irradiated adult SEC mice to determine which hemoglobin genes were expressed in each hemoglobin variant. Three offspring of irradiated SEC males did not express either of the two kinds of α-chains normally found in all SEC mice. The deficient α-chain synthesis caused these mice to exhibit an α-thalassemia similar to human α-thalassemia. Scanning electron microscopy was used to show that many erythrocytes of mice with α-thalassemia have bizarre shapes; e.g. many erythrocytes appeared flattened or had thorny projections (acanthocytes). One mutant with a tandem duplication of a segment of chromosome 7 (site of locus determining β-chain structure) produced twice as much SEC as 101 β-chain polypeptides. One mutant that probably arose by non-disjunction of chromosome 7's in its unirradiated 101 mother and loss of chromosome 7 from the gamete of its irradiated SEC father did not express the SEC β-chain gene. (author)

  11. Effect of Multiple Mutations in the Hemoglobin- and Hemoglobin-Haptoglobin-Binding Proteins, HgpA, HgpB, and HgpC, of Haemophilus influenzae Type b

    OpenAIRE

    Morton, Daniel J.; Whitby, Paul W.; Jin, Hongfan; Ren, Zhen; Stull, Terrence L.

    1999-01-01

    Haemophilus influenzae requires heme for growth and can utilize hemoglobin and hemoglobin-haptoglobin as heme sources. We previously identified two hemoglobin- and hemoglobin-haptoglobin-binding proteins, HgpA and HgpB, in H. influenzae HI689. Insertional mutation of hgpA and hgpB, either singly or together, did not abrogate the ability to utilize or bind either hemoglobin or the hemoglobin-haptoglobin complex. A hemoglobin affinity purification method was used to isolate a protein of approxi...

  12. Relationship between laparoscopic cholecystectomy operative time and carbonyl hemoglobin content

    Directory of Open Access Journals (Sweden)

    ZHANG Qi

    2013-06-01

    Full Text Available ObjectiveTo investigate whether operative time of laparoscopic cholecystectomy impacts the carbonyl hemoglobin (COHb concentration in peripheral blood. MethodsForty patients with gallstones and indications for laparoscopic cholecystectomy were enrolled in the study. Peripheral venous blood samples were collected at the beginning and end of the operative procedure. COHb concentration was measured by UV spectroscopy. The significance of changes in COHb concentration in relation to time of the operative procedure (rounded to the nearest minute was assessed by statistical correlation coefficient test. ResultsThe laparoscopic procedure was completed in 38 cases, and two patients required conversion to laparotomy. The content of COHb in peripheral venous blood had significantly increased during the laparoscopic operation (operation beginning: 11.07%±1.18% vs. operation end: 1.44%±0.26%, P<0.05. The change was positively correlated with operation time (r=0.85. ConclusionCarbon monoxide produced during the laparoscopic cholecystectomy procedure can lead to an increase in peripheral venous blood COHb. The longer the operation lasts, the greater the increase in COHb.

  13. Prevalence of Anemia and Hemoglobin Disorders Among School Children in Myanmar.

    Science.gov (United States)

    Wah, Saw Thu; Yi, Yoon Shwe; Khin, Aye Aye; Plabplueng, Chotiros; Nuchnoi, Pornlada

    2017-01-01

    The prevalence of anemia is high in the population of Myanmar and hypochromic microcytic anemia (HMA) is predominant. The objective of our study was to determine the prevalence of anemia and causes of HMA among school children. A cross-sectional study was conducted on 239 children from Thanlyin and Insein Townships, Yangon Region, Myanmar. Complete blood count (CBC) and blood film morphology was examined on venous blood samples. Hypochromic microcytic anemia cases were subsequently analyzed for serum ferritin and cellulose acetate hemoglobin (Hb) electrophoresis. The prevalence of anemia was 46.4%; 27.6% had mild, while 18.8% had moderate anemia, and no case of severe anemia was detected. The mean Hb concentration was 11.7 ± 0.9 g/dL. The younger age group (8-11 years) had a significantly higher prevalence of anemia than the older age group (12-15 years) (p = 0.029). Blood film morphology revealed a 50.6% red blood cell (RBC) disorder; HMA was the most common type (70.2%). Out of 85 children with HMA, three children (3.5%) had iron deficiency and all had comorbidity with Hb AE (β A /β E ) (Hb E trait). Hemoglobin electrophoresis illustrated that Hb AA (β A /β A ) (31, 36.5%) and Hb AE (β A /β E ) trait (31, 36.5%) were the most common types followed by β-thalassemia (β-thal) trait (19, 22.3%) and Hb EE (β E /β E ) (homozygous Hb E; HBB: c.79G>A) (three, 3.5%). Hematocrit [or packed cell volume (PCV)], mean corpuscular volume (MCV), mean corpuscular Hb (MCH) and mean corpuscular Hb concentration (MCHC), showed a significant difference between Hb AE, Hb EE and β-thal trait (p = 0.029, 0.023, 0.015 and 0.01, respectively). Our findings will provide valuable information for the management of anemia in the Myanmar school-age population.

  14. [Quantitative analysis of blood loss in liposuction].

    Science.gov (United States)

    Schor, N; Zatz, R M; Mendonça, A R; Takatu, P M; Patto, G S

    1989-01-01

    This study was performed in 15 female patients submitted to suction lipectomy as an isolated procedure, to establish blood loss in the procedure. A wide variation of blood-to-fat ratios was observed (17 to 59%) with a mean blood loss in lipoaspirates of 34 +/- 3%. Internal blood losses occurring in the first 72 post-operative hours were as important as or more important than external losses, and responsible for a mean 7% fall in the level of hemoglobin. Internal blood losses occurred between 72 hours and the 7th to the 10th post-operative days and were responsible for a mean 3% fall in the level of hemoglobin. Blood losses occurring in this study were demonstrated to be greater than usually assumed. Some prophylactic measures are recommended to provide for a safer treatment of these patients: an iron supplementation during the pre-operative period; careful clinical and laboratorial screening for bleeding disorders and for the intake of drugs that can interfere with coagulation; use of smaller-diameter cannulas for aspiration, auto-transfusion when aspirating in excess of 1,000 ml, and limiting the aspiration to 1,500 ml.

  15. Importance of glycosylation on function of a potassium channel in neuroblastoma cells.

    Directory of Open Access Journals (Sweden)

    M K Hall

    Full Text Available The Kv3.1 glycoprotein, a voltage-gated potassium channel, is expressed throughout the central nervous system. The role of N-glycans attached to the Kv3.1 glycoprotein on conducting and non-conducting functions of the Kv3.1 channel are quite limiting. Glycosylated (wild type, partially glycosylated (N220Q and N229Q, and unglycosylated (N220Q/N229Q Kv3.1 proteins were expressed and characterized in a cultured neuronal-derived cell model, B35 neuroblastoma cells. Western blots, whole cell current recordings, and wound healing assays were employed to provide evidence that the conducting and non-conducting properties of the Kv3.1 channel were modified by N-glycans of the Kv3.1 glycoprotein. Electrophoretic migration of the various Kv3.1 proteins treated with PNGase F and neuraminidase verified that the glycosylation sites were occupied and that the N-glycans could be sialylated, respectively. The unglycosylated channel favored a different whole cell current pattern than the glycoform. Further the outward ionic currents of the unglycosylated channel had slower activation and deactivation rates than those of the glycosylated Kv3.1 channel. These kinetic parameters of the partially glycosylated Kv3.1 channels were also slowed. B35 cells expressing glycosylated Kv3.1 protein migrated faster than those expressing partially glycosylated and much faster than those expressing the unglycosylated Kv3.1 protein. These results have demonstrated that N-glycans of the Kv3.1 glycoprotein enhance outward ionic current kinetics, and neuronal migration. It is speculated that physiological changes which lead to a reduction in N-glycan attachment to proteins will alter the functions of the Kv3.1 channel.

  16. Fasting blood glucose and haemoglobin concentrations of healthy ...

    African Journals Online (AJOL)

    Menstruation is associated with loss of blood monthly in women of reproductive age. In some women this physiological phenomenon is also associated with some complaints such as menstrual pain, vomiting, and tiredness. We investigated the fasting blood glucose concentration and hemoglobin concentration before and ...

  17. Biological role of site-specific O-glycosylation in cell adhesion activity and phosphorylation of osteopontin.

    Science.gov (United States)

    Oyama, Midori; Kariya, Yoshinobu; Kariya, Yukiko; Matsumoto, Kana; Kanno, Mayumi; Yamaguchi, Yoshiki; Hashimoto, Yasuhiro

    2018-05-09

    Osteopontin (OPN) is an extracellular glycosylated phosphoprotein that promotes cell adhesion by interacting with several integrin receptors. We previously reported that an OPN mutant lacking five O-glycosylation sites (Thr 134 /Thr 138 /Thr 143 /Thr 147 /Thr 152 ) in the threonine/proline-rich region increased cell adhesion activity and phosphorylation compared with the wild type. However, the role of O-glycosylation in cell adhesion activity and phosphorylation of OPN remains to be clarified. Here, we show that site-specific O-glycosylation in the threonine/proline-rich region of OPN affects its cell adhesion activity and phosphorylation independently and/or synergistically. Using site-directed mutagenesis, we found that OPN mutants with substitution sets of Thr 134 /Thr 138 or Thr 143 /Thr 147 /Thr 152 had decreased and increased cell adhesion activity, respectively. In contrast, the introduction of a single mutation into the O-glycosylation sites had no effect on OPN cell adhesion activity. An adhesion assay using function-blocking antibodies against αvβ3 and β1 integrins, as well as αvβ3 integrin-overexpressing A549 cells, revealed that site-specific O-glycosylation affected the association of OPN with the two integrins. Phosphorylation analyses using phos-tag and LC-MS/MS indicated that phosphorylation levels and sites were influenced by the O-glycosylation status, although the number of O-glycosylation sites was not correlated with the phosphorylation level in OPN. Furthermore, a correlation analysis between phosphorylation level and cell adhesion activity in OPN mutants with the site-specific O-glycosylation showed that they were not always correlated. These results provide conclusive evidence of a novel regulatory mechanism of cell adhesion activity and phosphorylation of OPN by site-specific O-glycosylation. © 2018 The Author(s). Published by Portland Press Limited on behalf of the Biochemical Society.

  18. Association of plasma ghrelin levels and ghrelin rs4684677 polymorphism with mild cognitive impairment in type 2 diabetic patients

    OpenAIRE

    Huang, Rong; Han, Jing; Tian, Sai; Cai, Rongrong; Sun, Jie; Shen, Yanjue; Wang, Shaohua

    2017-01-01

    Background and aims People with insulin resistance and type 2 diabetes mellitus (T2DM) are at increased risks of cognitive impairment. We aimed to investigate the association of plasma ghrelin levels and ghrelin rs4684677 polymorphism with mild cognitive impairment (MCI) in T2DM patients. Results In addition to elevated glycosylated hemoglobin (HbA1c), fasting blood glucose (FBG) and homeostasis model assessment of insulin resistance (HOMA-IR), T2DM patients with MCI had decreased plasma ghre...

  19. Moessbauer study of hemoglobin of diabetes

    International Nuclear Information System (INIS)

    Li Aiguo; Ni Xinbo; Cai Yingwen; Zhang Guilin; Zhang Hongde; Ge Yongxin

    2000-01-01

    The hemoglobins from normal adults (Gly-Hb 5%), people infected with diabetes (Gly-Hb 10%) and serious diabetics (Gly-Hb 15%) were investigated by Moessbauer spectroscopy at liquid nitrogen temperature. All the experimental spectra of hemoglobin are composed of three doublets corresponding to oxy-hemoglobin (Oxy-Hb), deoxy-hemoglobin (Deoxy-Hb) and low-spin hemo-chrome (Ls-Hemo) respectively. It is found that Oxy-Hb is decreasing but Deoxy-hb increasing for diabetes. Experimental results also indicate that the line-width of Moessbauer spectra of Oxy-Hb for diabetics is narrower than that for normal adults, showing that while Fe on Oxy-Hb exists in pile-up of some similar states for normal adults, but it becomes in single state for serious diabetes

  20. Selection of aptamers specific for glycated hemoglobin and total hemoglobin using on-chip SELEX.

    Science.gov (United States)

    Lin, Hsin-I; Wu, Ching-Chu; Yang, Ching-Hsuan; Chang, Ko-Wei; Lee, Gwo-Bin; Shiesh, Shu-Chu

    2015-01-21

    Blood glycated hemoglobin (HbA1c) levels reflecting average glucose concentrations over the past three months are fundamental for the diagnosis, monitoring, and risk assessment of diabetes. It has been hypothesized that aptamers, which are single-stranded DNAs or RNAs that demonstrate high affinity to a large variety of molecules ranging from small drugs, metabolites, or proteins, could be used for the measurement of HbA1c. Aptamers are selected through an in vitro process called systematic evolution of ligands by exponential enrichment (SELEX), and they can be chemically synthesized with high reproducibility at relatively low costs. This study therefore aimed to select HbA1c- and hemoglobin (Hb)-specific single-stranded DNA aptamers using an on-chip SELEX protocol. A microfluidic SELEX chip was developed to continuously and automatically carry out multiple rounds of SELEX to screen specific aptamers for HbA1c and Hb. HbA1c and Hb were first coated onto magnetic beads. Following several rounds of selection and enrichment with a randomized 40-mer DNA library, specific oligonucleotides were selected. The binding specificity and affinity were assessed by competitive and binding assays. Using the developed microfluidic system, the incubation and partitioning times were greatly decreased, and the entire process was shortened dramatically. Both HbA1c- and Hb-specific aptamers selected by the microfluidic system showed high specificity and affinity (dissociation constant, Kd = 7.6 ± 3.0 nM and 7.3 ± 2.2 nM for HbA1c and Hb, respectively). With further refinements in the assay, these aptamers may replace the conventional antibodies for in vitro diagnostics applications in the near future.