WorldWideScience

Sample records for glues

  1. Glue-paste linings

    DEFF Research Database (Denmark)

    Fuster-López, Laura; Andersen, Cecil Krarup; Bouillon, Nicolas

    2017-01-01

    Glue-paste linings of (Western) canvas paintings have been performed with a variety of materials throughout history and are present in a very significant amount of artworks in collections in Europe and elsewhere. Cereal flours and animal glues were usually the main ingredients because they were r...

  2. Fibrin glue in ophthalmology

    Directory of Open Access Journals (Sweden)

    Panda Anita

    2009-01-01

    Full Text Available Suturing is a time consuming task in ophthalmology and suture induced irritation and redness are frequent problems. Postoperative wound infection and corneal graft rejection are examples of possible suture related complications. To prevent these complications, ophthalmic surgeons are switching to sutureless surgery. A number of recent developments have established tissue adhesives like cyanoacrylate glue and fibrin glue as attractive alternatives to sutures. A possible and promising new application for tissue adhesives is to provide a platform for tissue engineering. Currently, tissue glue is being used for conjunctival closure following pterygium and strabismus surgery, forniceal reconstruction surgery, amniotic membrane transplantation, lamellar corneal grafting, closure of corneal perforations and descematoceles, management of conjunctival wound leaks after trabeculectomy, lid surgery, adnexal surgery and as a hemostat to minimise bleeding. The purpose of this review is to discuss the currently available information on fibrin glue.

  3. FIBRIN GLUE DAN APLIKASINYA

    Directory of Open Access Journals (Sweden)

    Agi Harliani S

    2015-08-01

    Full Text Available Fibrin Tissue Adhesive (FTA, Fibrin Sealant (FS or Fibrin Glue (FG are names given to a group of product that lead to the formation of fibrin clot at the site of application. Fibrin Glue represents a new revolution for local haemostatic, which produced by based on the understanding about blood coagulation process. The mechanism of FG mimics the last stage of blood coagulation process. Haemophilia, is a congenital inherited bleeding disorder, characterized by repeated bleeding episodes. The basic pathology is deficiency of factor VIII (hemophilia A or factor IX (hemophilia B. At bleeding episodes, hemophilia patients need replacement therapy. Hemophilia patients need transfusion of cryoprecipitate, Fresh Frozen Plasma (FFP or factor concentrate as replacement therapy. Oral surgery, dental extraction, circumcision, and orthopedic operations are the most important indications for fibrin glue in hemophilia care. As haemostatic local, FG minimizes bleeding, reducing the need of transfusion or factor concentrate, reducing the complication of transfusion, hospitalization and cost.

  4. Glue Guns: Aiming for Safety

    Science.gov (United States)

    Roy, Ken

    2010-01-01

    While glue guns are very useful, there are safety issues. Regardless of the temperature setting, glue guns can burn skin. The teacher should demonstrate and supervise the use of glue guns and have a plan should a student get burned. There should be an initial first aid protocol in place, followed by a visit to the school nurse. An accident report…

  5. Glue Sniffers with Special Needs.

    Science.gov (United States)

    O'Connor, Denis

    1987-01-01

    Glue sniffing and solvent misuse have seriously affected children and teenagers throughout the United Kingdom. This article discusses glue sniffing in terms of prevalence, association with disability, physical and psychological effects, signs and symptoms, counseling for sniffers, and successful interventions including an approach using videotape…

  6. BEWARE OF...SUPER GLUES!!

    CERN Multimedia

    2006-01-01

    What happened? A number of accidents have occurred with the use of 'Super Glues'. Some individuals have suffered injuries - severe irritation, or skin bonded together - through getting glue on their face and in their eyes. What are the hazards associated with glues? 'Super Glues' (i.e. cyanoacrylates): Are harmful if swallowed and are chemical irritants to the eyes, respiratory system and skin. Present the risk of polymerization (hardening) leading to skin damage. Be careful ! 'Super Glues' can bond to skin and eyes in seconds. Note: Other glues, resins and hardeners are also chemicals and as such can cause serious damage to the skin, eyes, respiratory or digestive tract. (For example: some components can be toxic, harmful, corrosive, sensitizing agents, etc.). How to prevent accidents in the future? Read the Material Safety Data Sheet (MSDS) for all of the glues you work with. Check the label on the container to find out which of the materials you work with are hazardous. Wear the right Per...

  7. 21 CFR 178.3120 - Animal glue.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Animal glue. 178.3120 Section 178.3120 Food and... and Production Aids § 178.3120 Animal glue. Animal glue may be safely used as a component of articles..., transporting, or holding food, subject to the provisions of this section. (a) Animal glue consists of the...

  8. The GlueX DIRC detector

    Science.gov (United States)

    Barbosa, F.; Bessuille, J.; Chudakov, E.; Dzhygadlo, R.; Fanelli, C.; Frye, J.; Hardin, J.; Kelsey, J.; Patsyuk, M.; Schwarz, C.; Schwiening, J.; Stevens, J.; Shepherd, M.; Whitlatch, T.; Williams, M.

    2017-12-01

    The GlueX DIRC (Detection of Internally Reflected Cherenkov light) detector is being developed to upgrade the particle identification capabilities in the forward region of the GlueX experiment at Jefferson Lab. The GlueX DIRC will utilize four existing decommissioned BaBar DIRC bar boxes, which will be oriented to form a plane roughly 4 m away from the fixed target of the experiment. A new photon camera has been designed that is based on the SuperB FDIRC prototype. The full GlueX DIRC system will consist of two such cameras, with the first planned to be built and installed in 2017. We present the current status of the design and R&D, along with the future plans of the GlueX DIRC detector.

  9. Glue Film Thickness Measurements by Spectral Reflectance

    International Nuclear Information System (INIS)

    Marshall, B.R.

    2010-01-01

    Spectral reflectance was used to determine the thickness of thin glue layers in a study of the effect of the glue on radiance and reflectance measurements of shocked-tin substrates attached to lithium fluoride windows. Measurements based on profilometry of the components were found to be inaccurate due to flatness variations and deformation of the tin substrate under pressure during the gluing process. The accuracy of the spectral reflectance measurements were estimated to be ±0.5 (micro)m, which was sufficient to demonstrate a convincing correlation between glue thickness and shock-generated light.

  10. Glue Film Thickness Measurements by Spectral Reflectance

    Energy Technology Data Exchange (ETDEWEB)

    B. R. Marshall

    2010-09-20

    Spectral reflectance was used to determine the thickness of thin glue layers in a study of the effect of the glue on radiance and reflectance measurements of shocked-tin substrates attached to lithium fluoride windows. Measurements based on profilometry of the components were found to be inaccurate due to flatness variations and deformation of the tin substrate under pressure during the gluing process. The accuracy of the spectral reflectance measurements were estimated to be ±0.5 μm, which was sufficient to demonstrate a convincing correlation between glue thickness and shock-generated light.

  11. Serum aluminium levels in glue-sniffer adolescent and in glue containers.

    Science.gov (United States)

    Akay, Cemal; Kalman, Süleyman; Dündaröz, Ruşen; Sayal, Ahmet; Aydin, Ahmet; Ozkan, Yalçin; Gül, Hüsamettin

    2008-05-01

    Glue sniffing is a serious medical problem among teenagers. Various chemical substances such as toluene and benzene containing glues have been reported to be toxic. It has been demonstrated that some toxic metals such as lead are elevated in the blood of solvent-addicted patients. Whereas aluminium is an element that has toxic effects on neurological, hematopoetic system and bone metabolism. We want to determine the serum levels of aluminium in glue-sniffer adolescents in comparison with healthy subjects. In addition, we compared aluminium levels of different commercial glue preparations (i.e. metal and plastic containers), to determine which type of container is better for less aluminium toxicity. We measured serum levels of aluminium in 37 glue-sniffer and 37 healthy subjects using atomic absorption spectrophotometry. The average duration of glue-sniffer was 3.8 +/- 0.8 years. We also measured aluminium levels of 10 commercial glue preparations that seven of them with metal and three with plastic containers. We found that serum levels of aluminium were 63.29 +/- 13.20 ng/ml and 36.7 +/- 8.60 ng/ml in glue-sniffer and in control subjects, respectively (P sniffers, it may be a good step to market of glue preparations in plastic instead of metal containers.

  12. Bovine glue (BioGlue) is catabolized by enzymatic reaction in the vascular dog model.

    Science.gov (United States)

    Van Belleghem, Yves; Forsyth, Ramses G; Narine, Kishan; Moerman, Annelies; Taeymans, Yves; Van Nooten, Guido J

    2004-06-01

    The aim of the study is to explore the feasibility, patency, and histologic changes of a sutureless vascular anastomotic technique using biological glue as sole fixation method. Eight mongrel dogs (+/-15 kg) underwent direct reanastomosis of their transsected iliac arteries. Both ends were placed on a 5-mm balloon and the anastomosis was secured with biological glue (BioGlue, Cryolife, Kennesaw, GA). No intravascular suture material was used. All survivors were angiographically controlled for patency after 6 weeks and 3 months. Then the animals were euthanized and tissues were obtained for histologic and pathologic examination by light and electron microscopy. All procedures were successful except for 1 animal that died of uncontrollable bleeding at the anastomotic site. All first-time angiographically controlled grafts except three were patent. One animal showed manifest signs of fungal infection. Histology detected early granulocyte infiltration with an important enzymatic reaction adjacent to the surface of glue. Later on, the glue gradually regressed to disappear completely. Fibroblastic neointimal lining was noticed in most of the anastomoses, with some marked differences in the endothelium compared with normal. Good permeability (57%) was observed in this new sutureless anastomotic technique in the canine model. In contrast to previous reported studies we noticed a clear enzymatic breakdown of the glue before total disappearance. It is not yet known to what extend use of the bovine glue was responsible for this phenomenon.

  13. The CostGlue XML Schema

    OpenAIRE

    Furfari, Francesco; Potort?, Francesco; Savić, Dragan

    2008-01-01

    An XML schema for scientific metadata is described. It is used for the CostGlue archival program, developed in the framework of the European Union COST Action 285: "Modelling and simulation tools for research in emerging multi-service telecommunications". The schema is freely available under the GNU LGPL license at http://wnet.isti.cnr.it/software/costglue/schema/2007/CostGlue.xsd, or at its official repository, at http://lt.fe.uni-lj. si/costglue/schema/2007/costglue.xsd.

  14. Hearing loss in a glue sniffer.

    Science.gov (United States)

    Williams, D M

    1988-10-01

    A case is presented of a 27-year-old glue sniffing woman with sensorineural hearing loss, optic atrophy and global brain damage. This form of addiction has not received much attention as a cause of otologic catastrophes, and should be borne in mind where similar cases come to the otolaryngologist.

  15. [Chemical hazards when working with solvent glues].

    Science.gov (United States)

    Domański, Wojciech; Makles, Zbigniew

    2012-01-01

    Solvent glues are used in a wide variety of industries, e.g., textile, footwear and rubber. The problem of workers' exposure to solvent vapors is rarely tackled within the area of occupational safety and health in small and medium-sized enterprises. In order to assess exposure to solvents, organic solvents emitted by glues were identified in the samples of workplace air. The concentration of acetone, benzene, cyclohexane, ethylbenzene, n-hexane, methylcyclohexane, butyl acetate and toluene were determined. The obtained results evidenced the presence of cyclohexane, ethylbenzene, ethylcyclohexane, heptane, n-hexane, o-xylene, methylcyclohexane, methylcyclopentane, butyl acetate and toluene in workplace air. The concentration of those compounds in workplace air was low, usually below 0.15 of MAC. At some workstations the presence of benzene was also observed. Occupational risk was assessed at workstations where gluing took place. It showed that the risk at those workstations was medium or low.

  16. Glue therapy in hemoptysis: A new technique

    Directory of Open Access Journals (Sweden)

    Rakesh K Chawla

    2012-01-01

    Full Text Available Hemoptysis is defined as the spitting of blood derived from the lungs or bronchial tubes as a result of pulmonary or bronchial hemorrhage. There is a large chunk of patients with hemoptysis who do not respond to conservative treatment including use of cough suppressants, antibiotics, vitamin C, hemostatics, and anxiolytics. The advanced management of such a situation is bronchial artery embolization (BAE or open thoracic surgery, which is often not possible. We have attempted a cheap, effective, and safe alternative in the form of intrabronchial instillation of glue (n-butyl cyanoacrylate under vision with the help of a therapeutic video bronchoscope (OLYMPUS T-180. The glue is instilled through a polyethylene catheter placed through the working channel of the video bronchoscope.

  17. Acute nonlymphocytic leukemia in a glue sniffer.

    Science.gov (United States)

    Caligiuri, M A; Early, A P; Marinello, M J; Preisler, H D

    1985-09-01

    A 17-year-old white male with a past history of chronic inhalational abuse of plastic glue was referred to our institution for sore throat, cervical adenopathy, and an abnormal peripheral blood smear. A diagnosis of acute myelomonocytic leukemia was made and abnormalities in cytogenetic studies were demonstrated. Specific inquiry regarding this form of drug exposure should be pursued when searching for possible etiologies of malignant disease.

  18. On the glue content in heavy quarkonia

    International Nuclear Information System (INIS)

    Gromes, D.

    2003-01-01

    Starting with two coupled Bethe-Salpeter equations for the quark-antiquark, and for the quark-glue-antiquark component of the quarkonium, we solve the bound state equations perturbatively. The resulting admixture of glue can be partially understood in a semiclassical way; one has, however, to take care of the different use of time ordered versus retarded Green functions. Subtle questions concerning the precise definition of the equal time wave function arise, because the wave function for the Coulomb gluon is discontinuous with respect to the relative time of the gluon. A striking feature is that a one loop non-abelian graph contributes to the same order as tree graphs, because the couplings of transverse gluons in the tree graphs are suppressed in the non-relativistic bound state, while the higher order loop graph can couple to quarks via non-suppressed Coulomb gluons. We also calculate the amplitude for quark and antiquark at zero distance in the quark-glue-antiquark component of the P-state. This quantity is of importance for annihilation decays of P-states. It shows a remarkable compensation between the tree graph and the non-abelian loop graph contribution. An extension of our results to include non-perturbative effects is possible. (orig.)

  19. Contact dermatitis to ethyl-cyanoacrylate-containing glue.

    Science.gov (United States)

    Belsito, D V

    1987-10-01

    3 patients with contact dermatitis to an ethyl cyanoacrylate glue are presented. Although reactions to cyanoacrylate glues are considered rare, more widespread use of these products by nail salons is likely to be associated with an increased incidence of positive reactions. All 3 of our patients came into contact with the glue during "nail wrapping". In this process, ethyl cyanoacrylate or another "instant glue" is used to adhere glue-impregnated silk or linen to the nail plate which is then filed to shape the nail. This procedure creates fine acrylic-containing dust which may facilitate an allergic response. Fine particulate matter may be transferred to other distant cutaneous sites, such as the eyelids, resulting in more widespread cutaneous eruptions. Dermatologists in areas where nail wrapping is becoming more fashionable are advised to be alert to potential cyanoacrylate glue allergies which present as periungual eczema which may be associated with eyelid dermatitis and features of nummular dermatitis particularly over the dorsal hand.

  20. Rejoining of cut wounds by engineered gelatin-keratin glue.

    Science.gov (United States)

    Thirupathi Kumara Raja, S; Thiruselvi, T; Sailakshmi, G; Ganesh, S; Gnanamani, A

    2013-08-01

    Rejoining of cut tissue ends of a critical site challenges clinicians. The toxicity, antigenicity, low adhesive strength, flexibility, swelling and cost of the currently employed glue demands an alternative. Engineered gelatin-keratin glue (EGK-glue) described in the present study was found to be suitable for wet tissue approximation. EGK-glue was prepared by engineering gelatin with caffeic acid using EDC and conjugating with keratin by periodate oxidation. UV-visible, (1)H NMR and circular dichroism analyses followed by experiments on gelation time, rheology, gel adhesive strength (in vitro), wet tissue approximation (in vivo), H&E staining of tissue sections at scheduled time intervals and tensile strength of the healed skin were carried out to assess the effectiveness of the EGK-glue in comparison with fibrin glue and cyanoacrylate. Results of UV-visible, NMR and CD analyses confirmed the functionalization and secondary structural changes. Increasing concentration of keratin reduces the gelation time (glue for clinical applications. Tissue approximation property assessed using the incision wound model (Wistar strain) in comparison with cyanoacrylate and fibrin glue suggested, that EGK-glue explicitly accelerates the rejoining of tissue with a 1.86 fold increase in skin tensile strength after healing. Imparting quinone moiety to gelatin-keratin conjugates through caffeic acid and a weaker oxidizing agent provides an adhesive glue with appreciable strength, and hemocompatible, cytocompatible and biodegradable properties, which, rejoin the cut tissue ends effectively. EGK-glue obtained in the present study finds wide biomedical/clinical applications. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Mussel glue protein has an open conformation.

    Science.gov (United States)

    Williams, T; Marumo, K; Waite, J H; Henkens, R W

    1989-03-01

    Both native glue protein from marine mussels and a synthetic nonhydroxylated analog were analyzed by far-uv CD under a variety of conditions. Analysis of the CD spectra using various models strongly suggest a primarily random coil structure for both forms of the protein, a fact also supported by the absence of spectral change for the glue protein upon dilution into 6 M guanidine hydrochloride. The nonhydroxylated analog, which consists of 20 repeats of the peptide sequence Ala-Lys-Pro-Ser-Tyr-Pro-Pro-Thr-Tyr-Lys, was further characterized by enzyme modification using mushroom tyrosinase. Enzymatic hydroxylation of tyrosines was found to be best fit by a model containing two rate constants, 5.6 (+/- 0.6) X 10(-3) and 7.2 (+/- 0.3) X 10(-2) min-1. At equilibrium, HPLC analysis of digests showed nearly 100% conversion of Tyr-9 and only 15 to 35% conversion of Tyr-5. The Chou and Fasman rules for predicting structure were applied to the repeat sequence listed above. The rules predict the absence of alpha helix and beta pleated sheets in the structure of this peptide. On the other hand, beta turns are predicted to be present with Tyr-5 being in the region of highest probability. These data suggest that the protein in solution has only a small amount of secondary structure.

  2. Comparison of two fibrin glues in anastomoses and skin closure.

    Science.gov (United States)

    Park, W; Kim, W H; Lee, C H; Kim, D Y; Choi, J H; Huh, J W; Sung, H M; Kim, I S; Kweon, O K

    2002-09-01

    To control intra-operative haemorrhage, fibrin glues are preferred by many surgeons because of their biological advantages and convenience of application. Manufacturers have developed a few kinds of fibrin glues with a little difference in their composition. This study was to compare the effectiveness of two commercially available fibrin glues; Greenplast (Green Cross P. D. Company, Yongin, Korea) and Tisseel (Baxter-Immuno AG, Vienna, Austria). They were applied experimentally to several kinds of surgery in dogs - renal vessel anastomosis, partial splenectomy, intestinal anastomosis and incision skin wound - and evaluated for their haemostatic and adhesive effects. When the two glues were applied in renal vessel anastomosis, the amount of haemorrhage in artery and vein decreased significantly. They also decreased the haemorrhage in partial splenectomy. At 10 min after application of the glues to an incision skin wound, the tensile strengths developed were significantly higher than that of control. The present study indicates that two-component fibrin glues have a haemostatic effect as a mechanical barrier in renal vessel anastomosis and an adhesive effect in the early stage of incision skin wound closure, and the two glues have similar effects with no complications.

  3. Histological effects of fibrin glue and synthetic tissue glues on the spinal cord: are they safe to use?

    Science.gov (United States)

    Kalsi, Pratipal; Thom, Maria; Choi, David

    2017-12-01

    Fibrin glues such as Tisseel ® have been established in neurosurgery for over thirty years. They are recommended for extradural use but have intradural applications. Brachial plexus reimplantation after trauma requires intradural fibrin glue because reimplanted nerves cannot be sutured to the spinal cord. Recently synthetic glues have become popular in spinal surgery but there is limited information about their safety. Our study compared the histological effects of Tisseel ® , Adherus ® and BioGlue ® on spinal cord using our rat brachial plexus repair model. Randomised observational animal study. Forty-one Sprague-Dawley rats divided in to control (n = 9), Tisseel ® (n = 8), BioGlue ® (n = 10) and Adherus ® (n = 14) groups. Under general anaesthesia a posterior midline cervical incision was made and hemi-laminectomies performed at C7 and T1. Dura was opened and T1 dorsal root transected and repositioned on the spinal cord. Two drops of Tisseel ® , BioGlue ® , Adherus ® or no glue (control) were applied over the cut nerve and cord. At days 7, 14 and 28 rats were euthanized, processed and sections stained with Haematoxylin & Eosin and evaluated blind by a neuropathologist. Control and Tisseel ® groups showed only mild focal inflammation in the cord. Adherus ® and Bioglue ® groups showed evidence of spinal cord inflammation and degeneration. All BioGlue ® and Adherus ® rats had evidence of distortion of the cord from the glue mass at all time points. Two BioGlue ® -treated and one Adherus ® -treated rat developed a hemiparesis. One BioGlue ® rat developed hind limb paralysis. One BioGlue ® rat failed to wake up at the end of the procedure. There were no complications in control and Tisseel ® groups. Tisseel ® caused a similar inflammatory response to control and may be used on spinal cord. BioGlue ® and Adherus ® should be applied thinly for a watertight dural closure but intradural use and contact with spinal tissue must be

  4. Properties of invariant modelling and invariant glueing of vector fields

    International Nuclear Information System (INIS)

    Petukhov, V.R.

    1987-01-01

    Invariant modelling and invariant glueing of both continuous (rates and accelerations) and descrete vector fields, gradient and divergence cases are considered. The following appendices are discussed: vector fields in crystals, crystal disclinations, topological charges and their fields

  5. Safety of Synthetic Glue Used for Laparoscopic Prolapse Treatment.

    Science.gov (United States)

    Sarasa Castelló, Núria; Toth, Alexandra; Canis, Michel; Botchorishvilli, Revaz

    2017-12-29

    We detected mesh erosion and serious postoperative complications in 3 women after performing laparoscopic promontofixation (LPF) using glue for mesh fixation. Glue, largely used in hernia surgery repair, is proposed by some gynecologic surgeons because it saves time and is easier to use than traditional sutures. We report 3 cases of postoperative complications after LPF in which glue had been used and provide research in the published literature about the use of glue in LPF. A research of glue use in gynecology mesh fixation was performed through PubMed on October 2016. The search was done using the Medical Subject Heading terms "POP" & "Laparoscopy" & "surgical Mesh" and the word either "glue" or "adhesive. Only 2 articles were found: Willecocq et al [1] and Estrade et al [2]. Neither study focused on postoperative complications. In this publication, we accurately edited video surgeries with an instructive purpose. University Hospital of Clermont-Ferrand, France. Patient A, a 65-year-old woman, complained of pelvic pain and vaginal discharge 1 month after LPF (polypropylene mesh and glue had been used). Wall mesh exposure and purulent discharge were noted. She received antibiotics and underwent mesh ablation surgery; debris of the glue was easily identified. Patient B, a 65-year-old lady with previous hysterectomy consulted for a bulging feeling in her vagina (classification: cystocele +2; rectocele +3 stage). An LPF was performed using polypropylene soft nonabsorbable mesh and glue. One month later, an apical defect of vaginal epithelialization was detected; she received long estrogenic local treatment but had to undergo surgery when presenting malodorous discharge and mesh exposure. The exposed mesh was removed, and pieces of glue were identified, having avoided mesh attachment. Patient C had a previous abdominal hysterectomy and promontofixation using a polyester mesh with glue. She consulted to us for vaginal mesh erosion covered with purulent discharge 3

  6. Information-provider scripts for GLUE2 and RAID configurations.

    CERN Document Server

    Kalimeris, Dimitrios

    2014-01-01

    This report will outline two projects that were done as part of a three months long summer internship at CERN. In the first project we dealt with Worldwide LHC Computing Grid (WLCG) and its information system. The information system currently conforms to a schema called GLUE and it is evolving towards a new version: GLUE2. The aim of the project was to develop and adapt the current information system of the WLCG, used by the Large Scale Storage Systems at CERN (CASTOR and EOS), to the new GLUE2 schema. During the second project we investigated different RAID configurations so that we can get performance boost from CERN's disk systems in the future. RAID 1 that is currently in use is not an option anymore because of limited performance and high cost. We tried to discover RAID configurations that will improve the performance and simultaneously decrease the cost.

  7. Caged Molecular Glues as Photoactivatable Tags for Nuclear Translocation of Guests in Living Cells.

    Science.gov (United States)

    Arisaka, Akio; Mogaki, Rina; Okuro, Kou; Aida, Takuzo

    2018-02-21

    We developed dendritic caged molecular glues ( Caged Glue-R) as tags for nucleus-targeted drug delivery, whose multiple guanidinium ion (Gu + ) pendants are protected by an anionic photocleavable unit (butyrate-substituted nitroveratryloxycarbonyl; BA NVOC). Negatively charged Caged Glue-R hardly binds to anionic biomolecules because of their electrostatic repulsion. However, upon exposure of Caged Glue-R to UV light or near-infrared (NIR) light, the BA NVOC groups of Caged Glue-R are rapidly detached to yield an uncaged molecular glue ( Uncaged Glue-R) that carries multiple Gu + pendants. Because Gu + forms a salt bridge with PO 4 - , Uncaged Glue-R tightly adheres to anionic biomolecules such as DNA and phospholipids in cell membranes by a multivalent salt-bridge formation. When tagged with Caged Glue-R, guests can be taken up into living cells via endocytosis and hide in endosomes. However, when the Caged Glue-R tag is photochemically uncaged to form Uncaged Glue-R, the guests escape from the endosome and migrate into the cytoplasm followed by the cell nucleus. We demonstrated that quantum dots (QDs) tagged with Caged Glue-R can be delivered efficiently to cell nuclei eventually by irradiation with light.

  8. Tests of optical glues for the PANDA electromagnetic calorimeter

    NARCIS (Netherlands)

    Dbeyssi, A.; Tomasi-Gustafsson, E.; Hennino, T.; Imre, M.; Kunne, R.; Le Galliard, C.; Marchand, D.; Maroni, A.; Ramstein, B.; Rosier, P.; Bremer, D.; Dormenev, V.; Eissner, T.; Kuske, T.; Novotny, R.; Moeini, H.; Bondarenko, O.; Kavatsyuk, M.; Loehner, H.; Messchendorp, G.; Tambave, G.

    2013-01-01

    This paper reports on the results of tests for low temperature applications of two commercial optical glues in the electromagnetic calorimeter of PANDA at FAIR. Mechanical, thermal and optical properties are presented, as well as radiation hardness to photon and proton radiation. (C) 2013 Elsevier

  9. Control of DNA hybridization by photoswitchable molecular glue.

    Science.gov (United States)

    Dohno, Chikara; Nakatani, Kazuhiko

    2011-12-01

    Hybridization of DNA is one of the most intriguing events in molecular recognition and is essential for living matter to inherit life beyond generations. In addition to the function of DNA as genetic material, DNA hybridization is a key to control the function of DNA-based materials in nanoscience. Since the hybridization of two single stranded DNAs is a thermodynamically favorable process, dissociation of the once formed DNA duplex is normally unattainable under isothermal conditions. As the progress of DNA-based nanoscience, methodology to control the DNA hybridization process has become increasingly important. Besides many reports using the chemically modified DNA for the regulation of hybridization, we focused our attention on the use of a small ligand as the molecular glue for the DNA. In 2001, we reported the first designed molecule that strongly and specifically bound to the mismatched base pairs in double stranded DNA. Further studies on the mismatch binding molecules provided us a key discovery of a novel mode of the binding of a mismatch binding ligand that induced the base flipping. With these findings we proposed the concept of molecular glue for DNA for the unidirectional control of DNA hybridization and, eventually photoswitchable molecular glue for DNA, which enabled the bidirectional control of hybridization under photoirradiation. In this tutorial review, we describe in detail how we integrated the mismatch binding ligand into photoswitchable molecular glue for DNA, and the application and perspective in DNA-based nanoscience.

  10. Effectiveness of Fibrin Glue in Adherence of Skin Graft.

    Science.gov (United States)

    Reddy, Konda Sireesha; Chittoria, Ravi Kumar; Babu, Preethitha; Marimuthu, Senthil Kumaran; Kumar, Sudhanva Hemanth; Subbarayan, Elan Kumar; Chavan, Vinayak; Mohapatra, Devi Prasad; Sivakumar, Dinesh Kumar; Friji, M T

    2017-01-01

    Graft fixation is important for graft take. Fibrin glue has been proposed as an ideal material, because of its human origin and it provides firm adhesion in seconds or minutes. To evaluate the efficiency of fibrin glue, in increasing the take of skin graft. Assessment includes surgical time taken for graft fixation, haematoma/seroma formation, engraftment and wound closure by day 14. The study is an observational prospective study conducted in the Department of Plastic Surgery, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, from January 2016 to June 2016. Sixteen patients who underwent split skin grafting were assessed during the study period. Fibrin glue was used on the recipient bed before grafting. Better haemostasis and graft adhesion, with a significant reduction of surgical time, were noted. The safety profile of fibrin glue was excellent as indicated by the lack of any related serious adverse experiences. These findings demonstrate that it is safe and effective for attachment of skin grafts, with outcomes at least as good as conventional methods.

  11. Contribution of glue layer into epidermis sample fluorescence dynamics

    Science.gov (United States)

    Salomatina, Elena V.; Chernova, Svetlana P.; Pravdin, Alexander B.

    2000-04-01

    In this work, the temporal behavior of autofluorescence of epidermis samples under UV-irradiation has ben studied. The samples were prepared using surface epidermis stripping technique. Fluorescence spectra and kinetic curves of fluorescence intensity have been obtained. It has been concluded that the glue composition used allows the measurement of epidermis fluorescence dynamics with the first 60 min of experiment.

  12. Gravity: The Glue of the Universe. History and Activities.

    Science.gov (United States)

    Gilbert, Harry; Smith, Diana Gilbert

    This book presents a story of the history of gravity, the glue of the universe, and is based on two premises: (1) an understanding of mathematics is not required to grasp the concepts and implications of relativity; and (2) relativity has altered forever the perceptions of gravity, space, time, and how the universe works. A narrative text section…

  13. Glue versus suture for mesh fixation in inguinal hernia repair.

    Science.gov (United States)

    Chandrasekar, Shruthi; Jeyakumar, S; Ganapathy, Tharun

    2018-03-22

    Inguinal hernia is one of the most common surgical problem presenting to the surgical OPD. Surgery is the mainstay of treatment for inguinal hernia today. Surgery for inguinal hernia has undergone a great evolution over a period of several centuries. Lichenstein's tension free hernioplasty is the one of the first surgeries taught to a surgical resident. The main aim of surgeries in this era is to give the best possible results with the least possible pain, scar and time. This has given rise to so many modifications to the classical Lichenstein's procedure and also to laparoscopic hernioplasty. Pain after inguinal hernia surgery is found to be debilitating and altering the quality of life in several patients, which has been attributed to the traumatic fixation of the mesh with sutures. This has paved way to the development of various atraumatic methods of fixation, tissue glue is one such development. Hence this study, to compare traumatic and atraumatic methods of mesh fixation in inguinal hernia repair. The aim of this study was to compare suture fixation versus tissue glue fixation of the mesh in inguinal hernia repair. Primary objective was to compare the immediate and chronic post-operative pain. Secondary objective was to compare the time taken for the procedure by the two methods in use and also to compare the presence of any complications. and methodology: This study was done in the General Surgery department of XXX hospital, medical college and research centre, kattangulathur after Ethics committee clearance. It is a single blinded study. The study was done on 51 patients consenting for the study and meeting the inclusion criterias from the period of March 2016 to August 2017 out of which 26 were selected for glue mesh fixation and 25 for suture mesh fixation according to simple randomization. The suture group patients underwent classical Lichenstein's tension free hernioplasty and the glue group underwent Lichenstein's hernioplasty with glue where dots of

  14. Towards GLUE2 evolution of the computing element information model

    CERN Document Server

    Andreozzi, S; Field, L; Kónya, B

    2008-01-01

    A key advantage of Grid systems is the ability to share heterogeneous resources and services between traditional administrative and organizational domains. This ability enables virtual pools of resources to be created and assigned to groups of users. Resource awareness, the capability of users or user agents to have knowledge about the existence and state of resources, is required in order utilize the resource. This awareness requires a description of the services and resources typically defined via a community-agreed information model. One of the most popular information models, used by a number of Grid infrastructures, is the GLUE Schema, which provides a common language for describing Grid resources. Other approaches exist, however they follow different modeling strategies. The presence of different flavors of information models for Grid resources is a barrier for enabling inter-Grid interoperability. In order to solve this problem, the GLUE Working Group in the context of the Open Grid Forum was started. ...

  15. Is there need for baryons with constituent glue

    International Nuclear Information System (INIS)

    Meissner, U.G.

    1983-01-01

    We investigate the breathing-mode spectrum of the Λ-particle in the framework of a general bag model including confinement via surface tension and volume energy. We show that the experimental states Λ 1/2 (1600) and Λ 1/2 (1800) can be described as radial surface excitations of the Λ. We further comment on a recent paper describing these Λ-excitations as baryons with constituent glue. (orig.)

  16. Glasses, Coatings, Glues and Gamma-ray Irradiation

    International Nuclear Information System (INIS)

    Barcala, J.M.; Fernandez, M. G.; Ferrando, A.; Fuentes, J.; Josa, M. I.; Molinero, A.; Oller, J. C.; Arce, P.; Calvo, E.; Figueroa, C. F.; Rodrigo, T.; Vila, I.; Virto, A. L.; Beigveder, J. M.; Genova, I.; Perez, G.; Ruiz, J. A.

    2001-01-01

    Most of the alignment systems for LHC experiments use optomechanical elements confirming a network of points that are monitored by laser beams. LHC experiments, working at the expected nominal luminosity, will induce an extremely high irradiation. basic components such as glasses, coatings and glues may change and their performance may degrade significantly. We have tested various components and identified some of them that can stand 10 years of LHC operation. (Author) 11 refs

  17. Glasses, Coatings, Glues and Gamma-ray Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Barcala, J.M.; Fernandez, M. G.; Ferrando, A.; Fuentes, J.; Josa, M. I.; Molinero, A.; Oller, J. C. [Ciemat. Madrid (Spain); Arce, P.; Calvo, E.; Figueroa, C. F.; Rodrigo, T.; Vila, I.; Virto, A. L. [Universidad de Cantabria. Santander (Spain); Beigveder, J. M.; Genova, I.; Perez, G.; Ruiz, J. A. [CIDA. Madrid (Spain)

    2001-07-01

    Most of the alignment systems for LHC experiments use optomechanical elements confirming a network of points that are monitored by laser beams. LHC experiments, working at the expected nominal luminosity, will induce an extremely high irradiation. basic components such as glasses, coatings and glues may change and their performance may degrade significantly. We have tested various components and identified some of them that can stand 10 years of LHC operation. (Author) 11 refs.

  18. Towards GLUE 2: evolution of the computing element information model

    International Nuclear Information System (INIS)

    Andreozzi, S; Burke, S; Field, L; Konya, B

    2008-01-01

    A key advantage of Grid systems is the ability to share heterogeneous resources and services between traditional administrative and organizational domains. This ability enables virtual pools of resources to be created and assigned to groups of users. Resource awareness, the capability of users or user agents to have knowledge about the existence and state of resources, is required in order utilize the resource. This awareness requires a description of the services and resources typically defined via a community-agreed information model. One of the most popular information models, used by a number of Grid infrastructures, is the GLUE Schema, which provides a common language for describing Grid resources. Other approaches exist, however they follow different modeling strategies. The presence of different flavors of information models for Grid resources is a barrier for enabling inter-Grid interoperability. In order to solve this problem, the GLUE Working Group in the context of the Open Grid Forum was started. The purpose of the group is to oversee a major redesign of the GLUE Schema which should consider the successful modeling choices and flaws that have emerged from practical experience and modeling choices from other initiatives. In this paper, we present the status of the new model for describing computing resources as the first output from the working group with the aim of dissemination and soliciting feedback from the community

  19. Use of Glubran 2 acrylic glue in interventional neuroradiology

    International Nuclear Information System (INIS)

    Raffi, L.; Simonetti, L.; Cenni, P.; Leonardi, M.

    2007-01-01

    Glubran 2 is a cyanoacrylate-based synthetic glue modified by the addition of a monomer synthesized by the manufacturer. With this material it is possible to obtain the stability of endovascular embolization that is needed to treat tumours and vascular disease. We report our 3-year experience of the use of Glubran for treating extracerebral tumours, spinal tumours, spinal arteriovenous malformations, and brain and spine dural fistulae. Glubran 2 was diluted with Lipiodol and injected in a continuous column with the flow rate monitored by seriography. The injection was stopped when retrograde flow was displayed in the afferent vessel. There were no periprocedural or subsequent clinical complications and the glue resulted in successful selective permanent occlusion with intralesional penetration similar to the angiographic features of microcatheterization. The embolization procedure was technically straightforward and relatively safe. However, Glubran 2 can be difficult to use and the procedure does carry major risks for patients. Glue injection requires in-depth study of the lesion, its circulation and the collateral circulation to avoid severe complications due to inappropriate use. (orig.)

  20. Research on preparation of phosphate-modified animal glue binder for foundry use

    Science.gov (United States)

    Wang, Tian-Shu; Liu, Wei-Hua; Li, Ying-Min

    2018-03-01

    In this paper, three phosphates were used as modifiers to modify animal glue binder. The structural characteristics and thermal properties of animal glue binder treated with phosphates were studied by Fourier transform-infrared spectroscopy, gel permeation chromatography and derivative thermogravimetric analysis. The results showed that the modified animal glue binder had better sand tensile strength and lower viscosity than untreated animal glue binder. The best modification process was as follows: the optimal amount of sodium carbonate was 4 wt% to animal glue; the optimal weight ratio of the modifiers was sodium pyrophosphate : sodium tripolyphosphate : sodium hexametaphosphate : animal glue = 3 : 3 : 4 : 100, and the optimal reaction should be performed at 80°C for a reaction time of 120 min. A final tensile strength of approximately 3.20 MPa was achieved and the viscosity value was approximately 880 mPa s.

  1. Compounds from silicones alter enzyme activity in curing barnacle glue and model enzymes.

    Science.gov (United States)

    Rittschof, Daniel; Orihuela, Beatriz; Harder, Tilmann; Stafslien, Shane; Chisholm, Bret; Dickinson, Gary H

    2011-02-17

    Attachment strength of fouling organisms on silicone coatings is low. We hypothesized that low attachment strength on silicones is, in part, due to the interaction of surface available components with natural glues. Components could alter curing of glues through bulk changes or specifically through altered enzyme activity. GC-MS analysis of silicone coatings showed surface-available siloxanes when the coatings were gently rubbed with a cotton swab for 15 seconds or given a 30 second rinse with methanol. Mixtures of compounds were found on 2 commercial and 8 model silicone coatings. The hypothesis that silicone components alter glue curing enzymes was tested with curing barnacle glue and with commercial enzymes. In our model, barnacle glue curing involves trypsin-like serine protease(s), which activate enzymes and structural proteins, and a transglutaminase which cross-links glue proteins. Transglutaminase activity was significantly altered upon exposure of curing glue from individual barnacles to silicone eluates. Activity of purified trypsin and, to a greater extent, transglutaminase was significantly altered by relevant concentrations of silicone polymer constituents. Surface-associated silicone compounds can disrupt glue curing and alter enzyme properties. Altered curing of natural glues has potential in fouling management.

  2. Stroke from Delayed Embolization of Polymerized Glue Following Percutaneous Direct Injection of a Carotid Body Tumor

    Energy Technology Data Exchange (ETDEWEB)

    Krishnamoorthy, Thamburaj; Gupta, Arun Kumar; Rajan, Jayadevan E; Thomas, Bejoy [Sree Chitra Tirunal Institute for Medical Sciences and Technology, Trivandrum, Kerala, (India)

    2007-06-15

    Direct percutaneous embolization of hypervascular tumors results in more effective preoperative devascularization. Migration of glue is a well known complication of direct glue injection and it may lead to stroke or cranial nerve deficits. We report here on a case of carotid body tumor in a 52-year-old man; the tumor was mainly embolized by percutaneous injection of 50% glue and this was supported with balloon protection of the internal carotid artery. Thirteen hours later, he developed hemiparesis from delayed migration of glue. The possible mechanisms of this migration are discussed and preventive measures are suggested. Preoperative embolization of hypervascular tumors of the head and neck, including carotid body tumor, is often performed to decrease the amount of blood loss during surgery. Devascularization is mainly performed with particulate agents and by employing the transarterial route. More effective embolization may be achieved by performing percutaneous direct embolization of hypervascular tumors with liquid embolic agents. Even though there are few reports available on direct embolization, complications from glue migration have been reported, and this mainly happens during the procedure when the glue is in a liquid state. We report here on a case of delayed migration of polymerized glue (n-butyl-2-cyanoacrylate [NBCA]), many hours after the procedure, into the intracranial circulation and the final result was stroke. A 52-year-old male with right carotid body tumor underwent direct percutaneous glue (n-butylcyanoacrylate [NBCA]) embolization. Several hours later, he developed left hemiparesis from embolization of the polymerized glue cast. Migration of glue during percutaneous tumor embolization is presumed to occur only in the liquid state, which may lead to stroke or cranial nerve deficits. To the best of our knowledge, this is the first report of delayed glue embolization from a treated hypervascular tumor of the head and neck.

  3. The GlueX central drift chamber: Design and performance

    International Nuclear Information System (INIS)

    Van Haarlem, Y.; Meyer, C.A.; Barbosa, F.; Dey, B.; Lawrence, D.; Razmyslovich, V.; Smith, E.; Visser, G.; Whitlatch, T.; Wilkin, G.; Zihlmann, B.

    2010-01-01

    Tests and studies concerning the design and performance of the GlueX Central Drift Chamber (CDC) are presented. A full-scale prototype was built to test and steer the mechanical and electronic design. Small scale prototypes were constructed to test for sagging and to do timing and resolution studies of the detector. These studies were used to choose the gas mixture and to program a Monte Carlo simulation that can predict the detector response in an external magnetic field. Particle identification and charge division possibilities were also investigated.

  4. First Results from The GlueX Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Curtis [Carnegie Mellon Univ., Pittsburgh, PA (United States)

    2016-05-01

    The GlueX experiment at Jefferson Lab ran with its first commissioning beam in late 2014 and the spring of 2015. Data were collected on both plastic and liquid hydrogen targets, and much of the detector has been commissioned. All of the detector systems are now performing at or near design specifications and events are being fully reconstructed, including exclusive production of pi^0, eta and omega mesons. Linearly-polarized photons were successfully produced through coherent bremsstrahlung and polarization transfer to the ρ has been observed.

  5. Three-dimensional glue detection and evaluation based on linear structured light

    Science.gov (United States)

    Xiao, Zhitao; Yang, Ruipeng; Geng, Lei; Liu, Yanbei

    2018-01-01

    During the online glue detection of body in white (BIW), the purpose of traditional glue detection based on machine vision is the localization and segmentation of glue, which is dissatisfactory for estimating the uniformity of glue with complex shape. A three-dimensional glue detection method based on the linear structured light and the movement parameters of robot is proposed. Firstly, the linear structured light and epipolar constraint algorithm are used for sign matching of binocular vision. Then, hand-eye relationship between robot and binocular camera is utilized to unified coordinate system. Finally, a structured light stripe extraction method is proposed to extract the sub-pixel coordinates of the light strip center. Experiments results demonstrate that the propose method can estimate the shape of glue accurately. For three kinds of glue with complex shape and uneven illumination, our method can detect the positions of blemishes. The absolute error of measurement is less than 1.04mm and the relative error is less than 10% respectively, which is suitable for online glue detection in BIW.

  6. Linkage and mapping analyses of the no glue egg gene Ng in the ...

    African Journals Online (AJOL)

    In the silkworm, Bombyx mori, no glue egg is mainly controlled by Ng (No glue) gene, which is located on the 12th chromosome. Owning to a lack of crossing over in females, reciprocal backcrossed F1 (BC1) progenies were used for linkage analysis and mapping of the Ng gene based on the simple sequence repeats ...

  7. Effect of MHEC on evaporation and hydration characteristics of glue mortar

    NARCIS (Netherlands)

    Faiyas, A.P.A.; Erich, S.J.F.; Huinink, H.P.; Adan, O.C.G; Nijland, T.G.

    2016-01-01

    The influence of methylhydroxyethylcellulose (MHEC) on both moisture distribution and hydration characteristics of glue mortar using nuclear magnetic resonance imaging (NMR) is investigated. MHEC is added to glue mortar in order to control the drying rate by increasing the open time. Besides drying,

  8. Photoproduction of the Cascade Baryons at GlueX

    Science.gov (United States)

    Ernst, Ashley; GlueX Collaboration

    2017-09-01

    Multi-strange baryons play an important role in understanding the strong interaction and despite their importance, little is known about such hyperons. Almost all knowledge of the Cascades today stems from Kaon-nucleon interactions in bubble chamber experiments performed in the 1960s and 1970s, of which only the octet and decuplet ground states, Ξ (1320) and Ξ (1530) respectively, are well established. This research uses the GlueX experiment at Jefferson Laboratory to map out the spectrum of doubly-strange Cascade resonances, as well as to measure the spin-parity for each of the detected resonances. The first physics run for GlueX has recently been completed and a clear signature of the Ξ (1320) is observed. The systematics of the Cascade spectrum will be presented motivated by prior discoveries in the N* program. This work was supported by the U.S. Department of Energy Grant DE-FG02-92ER40735 and National Science Foundation Grant 1449440.

  9. Sediment Curve Uncertainty Estimation Using GLUE and Bootstrap Methods

    Directory of Open Access Journals (Sweden)

    aboalhasan fathabadi

    2017-02-01

    Full Text Available Introduction: In order to implement watershed practices to decrease soil erosion effects it needs to estimate output sediment of watershed. Sediment rating curve is used as the most conventional tool to estimate sediment. Regarding to sampling errors and short data, there are some uncertainties in estimating sediment using sediment curve. In this research, bootstrap and the Generalized Likelihood Uncertainty Estimation (GLUE resampling techniques were used to calculate suspended sediment loads by using sediment rating curves. Materials and Methods: The total drainage area of the Sefidrood watershed is about 560000 km2. In this study uncertainty in suspended sediment rating curves was estimated in four stations including Motorkhane, Miyane Tonel Shomare 7, Stor and Glinak constructed on Ayghdamosh, Ghrangho, GHezelOzan and Shahrod rivers, respectively. Data were randomly divided into a training data set (80 percent and a test set (20 percent by Latin hypercube random sampling.Different suspended sediment rating curves equations were fitted to log-transformed values of sediment concentration and discharge and the best fit models were selected based on the lowest root mean square error (RMSE and the highest correlation of coefficient (R2. In the GLUE methodology, different parameter sets were sampled randomly from priori probability distribution. For each station using sampled parameter sets and selected suspended sediment rating curves equation suspended sediment concentration values were estimated several times (100000 to 400000 times. With respect to likelihood function and certain subjective threshold, parameter sets were divided into behavioral and non-behavioral parameter sets. Finally using behavioral parameter sets the 95% confidence intervals for suspended sediment concentration due to parameter uncertainty were estimated. In bootstrap methodology observed suspended sediment and discharge vectors were resampled with replacement B (set to

  10. Fibrin glue as agent for sealing corneal and conjunctival wound leaks.

    Science.gov (United States)

    Scalcione, C; Ortiz-Vaquerizas, D; Said, D G; Dua, H S

    2018-02-01

    PurposeTo describe a novel use of fibrin glue in managing leaking blebs and leaking wounds following trauma or surgery.MethodsInterventional case series.ResultsWe report eight patients, including three where intra-operative or immediate post-penetrating keratoplasty recalcitrant leaks from the graft-host junction and/or openings created by the needle pass, were noted. All three had thin recipient beds in the sector of leak. This was managed by intra-cameral injection of fibrin glue in the affected quadrant. This stopped the leak and allowed the defect to heal. One patient of Descemets-stripping-endothelial-keratoplasty had leak from the surgical wound, which was also sealed with fibrin glue. Two patients with leaking glaucoma-surgery-related blebs were treated with intra-bleb injection of fibrin glue to stop the leak. One patient with a penetrating corneal injury with a metal wire had a brisk leak upon removal of the wire. This was sealed with fibrin glue. Another patient of chemical burn with spontaneous leaks was managed by glue injection in the perforations. Transient rise of intraocular pressure in one patient with a leaking bleb was the only adverse event recorded.ConclusionThis novel adaptation of the application of fibrin glue can help to deal with persistent intra-operative, post-operative and traumatic aqueous and air leaks.

  11. Fibrin Glue Does Not Improve Healing of Gastrointestinal Anastomoses

    DEFF Research Database (Denmark)

    Nordentoft, Tyge; Pommergaard, Hans-Christian; Rosenberg, Jacob

    2015-01-01

    BACKGROUND/AIM: Anastomotic leakage remains a frequent and serious complication in gastrointestinal surgery. In order to reduce its incidence, several clinical and experimental studies on anastomotic sealing have been performed. In a number of these studies, the sealing material has been fibrin...... glue (FG), and the results in individual studies have been varying. The positive effect of anastomotic sealing with FG might be due to the mechanical/physical properties, the increased healing of the anastomoses or both. The aim of this systematic review was to evaluate the existing evidence....... It is consequently plausible that the positive effect of FG sealing of gastrointestinal anastomoses, if there is any, may be due to a mechanical sealing effect rather than due to improved healing per se....

  12. Krazy Glue® in the ear: A case report of child abuse.

    Science.gov (United States)

    Sorichetti, Brendan D; Fandiño, Marcela; Kozak, Frederick K

    2018-06-01

    Krazy Glue ® or cyanoacrylate glue is an acrylic resin that polymerizes in less than a minute when in contact with moisture or water. We present a case of a one month old referred to our tertiary pediatric otolaryngology clinic from an outside emergency department with a history of application of cyanoacrylate glue in the external ear canals. This report presents the management of this case along with the medical and legal outcomes surrounding this case of child abuse. Copyright © 2018. Published by Elsevier B.V.

  13. Observations on dimensional changes of sized canvas based on glue temperature

    DEFF Research Database (Denmark)

    Krarup Andersen, Cecil

    2008-01-01

    The aim of this study was to explore dimensional changes caused by water on sized canvas. Samples of new linen canvas were mounted on a rig for biaxial tensioning, holding a constant stress of 100 N/m in both weave directions. The samples were then sized with respectively warm fluent glue (45 °C......) or a cold gel (20 °C), both consisting of a 5 percent sheepskin glue extracted from parchment clippings. The warm glue was absorbed into the canvas structure, whereas the cold gel mostly stayed as a discrete layer on the canvas. Twice the amount of glue was therefore needed for the warm sizing. When...... of size layers during application is important to the dimensional reaction of a canvas painting that is exposed to water....

  14. Event based uncertainty assessment in urban drainage modelling, applying the GLUE methodology

    DEFF Research Database (Denmark)

    Thorndahl, Søren; Beven, K.J.; Jensen, Jacob Birk

    2008-01-01

    of combined sewer overflow. The GLUE methodology is used to test different conceptual setups in order to determine if one model setup gives a better goodness of fit conditional on the observations than the other. Moreover, different methodological investigations of GLUE are conducted in order to test......In the present paper an uncertainty analysis on an application of the commercial urban drainage model MOUSE is conducted. Applying the Generalized Likelihood Uncertainty Estimation (GLUE) methodology the model is conditioned on observation time series from two flow gauges as well as the occurrence...... if the uncertainty analysis is unambiguous. It is shown that the GLUE methodology is very applicable in uncertainty analysis of this application of an urban drainage model, although it was shown to be quite difficult of get good fits of the whole time series....

  15. Sealing of Gastrointestinal Anastomoses with a Fibrin Glue-Coated Collagen Patch: A Safety Study

    DEFF Research Database (Denmark)

    Nordentoft, Tyge; Rømer, John; Sørensen, Michael

    2007-01-01

    gastrointestinal anastomoses with a collagen patch coated with fibrin glue. The study is a prospective, experimental animal study comparing sealed and unsealed gastrointestinal anastomoses. Laparotomy was performed in 11 pigs under general anesthesia. In each pig two anastomoses were performed on the small......Sealing of anastomoses has previously been tested with several methods, including sealing with liquid fibrin glue. Sealing with a collagen patch coated with fibrin glue components has never been systematically examined. The aim of the present study was to determine the safety of sealing...... intestine. One of the anastomoses was sealed with a collagen patch coated with fibrin glue components (TachoSil). The other anastomosis contained no sealing. The pigs were observed for 1 to 6 weeks. The observation period was followed by in vivo examination under general anesthesia and included observation...

  16. The use of snake venom derived fibrin glue in hysterorrhaphy of ovine caesarean surgery

    OpenAIRE

    CHALHOUB, M.; PRESTES, N. C.; LOPES, M. D.; ROCHA, N. S.; THOMAZINI-SANTOS, I. A.; MENDES-GIANNINI, M.J.

    2000-01-01

    Fibrin glue has been used on its own or in conjunction with suturing materials to promote hemostasis, reduce adherence, strengthen the wound site, and improve healing. Snake venom derived fibrin glue was evaluated as an alternative to conventional uterine suturing after ovine caesarean surgery. Twenty-eight pregnant ewes of known mating date were used. The animals submitted to conventional caesarean sections showed a better wound healing process. As expected, all the operated animals had reta...

  17. Experimental closure of gunshot wounds by fibrin glue with antibiotics in pigs

    OpenAIRE

    Đenić Nebojša; Višnjić Milan; Dragović Saša; Bojanić Vladmila; Bojanić Zoran; Đurđević Dragan; Đinđić Boris; Kostov Miloš

    2015-01-01

    Background/Aim. Gunshot wounds caused by the automatic rifle M70AB2 (AK-47) 7.62 mm, after the primary surgical management, were closed with delayed primary suture during the next four to seven days. This period coincides with the fibroblastic phase of wound healing. Fibrin glue is used as a local hemostatic and as a matrix for the local dosed release of antibiotics. Antibiotics addition to fibrin glue resulted in continuous diffusion into the surrounding n...

  18. Measurement of radiation damage on an epoxy-based optical glue

    International Nuclear Information System (INIS)

    Huang, H.C.; Peng, K.C.; Sahu, S.K.; Ueno, K.; Chang, Y.H.; Wang, C.H.; Hou, W.S.

    1997-01-01

    We measured the radiation damage on an optical glue called Eccobond-24, which is a candidate for CsI and BGO crystal calorimeters of the BELLE detector of the KEK B-factory. Absorption spectrophotometry in the range 300-800 nm was used to monitor the radiation damage. The maximum equivalent dose was 1.64 Mrad. The glue shows effects of damage, but is acceptable for the radiation level in the above-mentioned experiment. (orig.)

  19. Double Coaxial Microcatheter Technique for Glue Embolization of Renal Arteriovenous Malformations

    International Nuclear Information System (INIS)

    Uchikawa, Yoko; Mori, Kensaku; Shiigai, Masanari; Konishi, Takahiro; Hoshiai, Sodai; Ishigro, Toshitaka; Hiyama, Takashi; Nakai, Yasunobu; Minami, Manabu

    2015-01-01

    PurposeTo demonstrate the technical benefit of the double coaxial microcatheter technique for embolization of renal arteriovenous malformations (AVMs) with n-butyl cyanoacrylate and iodized oil (glue).Materials and MethodsSix consecutive patients (1 man and 5 women; mean age 61 years; range 44–77 years) with renal AVMs were included. Five patients had hematuria, and one had a risk of heart failure due to a large intrarenal arteriovenous shunt. All patients underwent transarterial embolization using glue and the double coaxial microcatheter technique with outer 2.6F and inner 1.9F microcatheters. After glue injection, the inner microcatheter was retracted, while the outer microcatheter was retained. We assessed the complications and clinical outcomes of this technique.ResultsTechnical success was achieved in all patients. In 9 sessions, 34 feeding arteries were embolized with glue using the double coaxial microcatheter technique, 1 was embolized with glue using a single microcatheter, and 2 were embolized with coils. The double coaxial microcatheter technique was useful for selecting small tortuous feeding arteries, preventing glue reflux to the proximal arteries, and approaching multiple feeding arteries without complete retraction of the microcatheters. As a minor complication, glue migrated into the venous system in four patients without any sequelae. In all patients, favorable clinical outcomes, including hematuria cessation in five patients and improvement of the large intrarenal arteriovenous shunt in one patient, were obtained without deterioration of renal function.ConclusionGlue embolization with the double coaxial microcatheter technique was useful for treating renal AVMs with multiple tortuous feeding arteries

  20. Double Coaxial Microcatheter Technique for Glue Embolization of Renal Arteriovenous Malformations

    Energy Technology Data Exchange (ETDEWEB)

    Uchikawa, Yoko, E-mail: jauchikawa@gmail.com [University of Tsukuba Hospital, Department of Radiology (Japan); Mori, Kensaku, E-mail: moriken@md.tsukuba.ac.jp [University of Tsukuba, Department of Radiology, Faculty of Medicine (Japan); Shiigai, Masanari, E-mail: m-41gai@yahoo.co.jp [Tsukuba Medical Center Hospital, Department of Radiology (Japan); Konishi, Takahiro, E-mail: soratobukangaruu@gmail.com [University of Tsukuba Hospital, Department of Radiology (Japan); Hoshiai, Sodai, E-mail: hoshiai@sb4.so-net.ne.jp [Ibaraki Prefectural Central Hospital, Department of Radiology (Japan); Ishigro, Toshitaka, E-mail: suzutokei@gmail.com; Hiyama, Takashi, E-mail: med-tak@hotmail.com [University of Tsukuba Hospital, Department of Radiology (Japan); Nakai, Yasunobu, E-mail: nakaiya@tmch.or.jp [Tsukuba Medical Center Hospital, Department of Neurosurgery (Japan); Minami, Manabu, E-mail: mminami@md.tsukuba.ac.jp [University of Tsukuba, Department of Radiology, Faculty of Medicine (Japan)

    2015-10-15

    PurposeTo demonstrate the technical benefit of the double coaxial microcatheter technique for embolization of renal arteriovenous malformations (AVMs) with n-butyl cyanoacrylate and iodized oil (glue).Materials and MethodsSix consecutive patients (1 man and 5 women; mean age 61 years; range 44–77 years) with renal AVMs were included. Five patients had hematuria, and one had a risk of heart failure due to a large intrarenal arteriovenous shunt. All patients underwent transarterial embolization using glue and the double coaxial microcatheter technique with outer 2.6F and inner 1.9F microcatheters. After glue injection, the inner microcatheter was retracted, while the outer microcatheter was retained. We assessed the complications and clinical outcomes of this technique.ResultsTechnical success was achieved in all patients. In 9 sessions, 34 feeding arteries were embolized with glue using the double coaxial microcatheter technique, 1 was embolized with glue using a single microcatheter, and 2 were embolized with coils. The double coaxial microcatheter technique was useful for selecting small tortuous feeding arteries, preventing glue reflux to the proximal arteries, and approaching multiple feeding arteries without complete retraction of the microcatheters. As a minor complication, glue migrated into the venous system in four patients without any sequelae. In all patients, favorable clinical outcomes, including hematuria cessation in five patients and improvement of the large intrarenal arteriovenous shunt in one patient, were obtained without deterioration of renal function.ConclusionGlue embolization with the double coaxial microcatheter technique was useful for treating renal AVMs with multiple tortuous feeding arteries.

  1. Highly Stretchable, Biocompatible, Striated Substrate Made from Fugitive Glue

    Directory of Open Access Journals (Sweden)

    Wei Li

    2015-06-01

    Full Text Available We developed a novel substrate made from fugitive glue (styrenic block copolymer that can be used to analyze the effects of large strains on biological samples. The substrate has the following attributes: (1 It is easy to make from inexpensive components; (2 It is transparent and can be used in optical microscopy; (3 It is extremely stretchable as it can be stretched up to 700% strain; (4 It can be micro-molded, for example we created micro-ridges that are 6 μm high and 13 μm wide; (5 It is adhesive to biological fibers (we tested fibrin fibers, and can be used to uniformly stretch those fibers; (6 It is non-toxic to cells (we tested human mammary epithelial cells; (7 It can tolerate various salt concentrations up to 5 M NaCl and low (pH 0 and high (pH 14 pH values. Stretching of this extraordinary stretchable substrate is relatively uniform and thus, can be used to test multiple cells or fibers in parallel under the same conditions.

  2. From glue to gasoline: how competition turns perspective takers unethical.

    Science.gov (United States)

    Pierce, Jason R; Kilduff, Gavin J; Galinsky, Adam D; Sivanathan, Niro

    2013-10-01

    Perspective taking is often the glue that binds people together. However, we propose that in competitive contexts, perspective taking is akin to adding gasoline to a fire: It inflames already-aroused competitive impulses and leads people to protect themselves from the potentially insidious actions of their competitors. Overall, we suggest that perspective taking functions as a relational amplifier. In cooperative contexts, it creates the foundation for prosocial impulses, but in competitive contexts, it triggers hypercompetition, leading people to prophylactically engage in unethical behavior to prevent themselves from being exploited. The experiments reported here establish that perspective taking interacts with the relational context--cooperative or competitive--to predict unethical behavior, from using insidious negotiation tactics to materially deceiving one's partner to cheating on an anagram task. In the context of competition, perspective taking can pervert the age-old axiom "do unto others as you would have them do unto you" into "do unto others as you think they will try to do unto you."

  3. Fibrin glue as a protective tool for microanastomoses in limb reconstructive surgery

    Directory of Open Access Journals (Sweden)

    Langer, Stefan

    2015-12-01

    Full Text Available Aim: Fibrin glue becomes a more and more routinely used tool for stabilization of microanastomoses and nerve repair. This paper summarizes the technical properties and advantages of its use in a wide variety of microsurgical contexts, and includes an exemplary limb reconstructive case.Patients and methods: A total of 131 patients who had undergone elective and emergency microsurgery mainly of the limbs were retrospectively analyzed, as was the use of free flaps.Results: The use of fibrin glue allows for proper positioning of anastomoses and repaired nerves. No torsion of the pedicle could be seen. The flap survival rated >94%. The fibrin glue could stay in place in >99%. In the rare case of revision, the fibrin glue could easily be removed without damaging the region of the microanastomosis.Conclusion: Fibrin glue should not be used to repair insufficient, i.e., leaking anastomoses, but it does protect the site of anastomosis from tissue and fluid pressure. It prevents the pedickle from torsion and its use facilitates relocation of the microanastomoses in cases of revision surgery.

  4. Glue detection based on teaching points constraint and tracking model of pixel convolution

    Science.gov (United States)

    Geng, Lei; Ma, Xiao; Xiao, Zhitao; Wang, Wen

    2018-01-01

    On-line glue detection based on machine version is significant for rust protection and strengthening in car production. Shadow stripes caused by reflect light and unevenness of inside front cover of car reduce the accuracy of glue detection. In this paper, we propose an effective algorithm to distinguish the edges of the glue and shadow stripes. Teaching points are utilized to calculate slope between the two adjacent points. Then a tracking model based on pixel convolution along motion direction is designed to segment several local rectangular regions using distance. The distance is the height of rectangular region. The pixel convolution along the motion direction is proposed to extract edges of gules in local rectangular region. A dataset with different illumination and complexity shape stripes are used to evaluate proposed method, which include 500 thousand images captured from the camera of glue gun machine. Experimental results demonstrate that the proposed method can detect the edges of glue accurately. The shadow stripes are distinguished and removed effectively. Our method achieves the 99.9% accuracies for the image dataset.

  5. The Effect of Seaweed Glue in the Separation of Copper–Molybdenum Sulphide Ore by Flotation

    Directory of Open Access Journals (Sweden)

    Zhixiang Chen

    2018-01-01

    Full Text Available Flotation separation of chalcopyrite from molybdenite was studied using seaweed glue (SEG as a depressant. Flotation process and mechanism were examined by response surface methodology, flotation tests, adsorption tests, zeta potential measurements and fourier transform infrared (FT-IR spectra. Response surface methodology with a Box–Behnken design suggested the optimal reagent schedule: pH 4, depressant seaweed glue 197 mg/L, collector amyl xanthate 16 mg/L and frother (methyl isobutyl carbinol 20 mg/L, and selective separation of chalcopyrite and molybdenite was achieved by flotation. Comparison of SEG and traditional depressants indicated that the SEG could achieve a similar separation efficiency, and exhibited the advantages of environmental compatibility and economic adaptability. Co-adsorption of seaweed glue and amyl xanthate occurred on the surface of molybdenite, and is explained to happen through distinct mechanisms due to the heterogeneous nature of the surface. It is likely that seaweed glue depresses molybdenite by covering the dixanthogen resulting from adsorption of xanthate ions. It is shown that seaweed glue is as effective a depressant of Cu/Mo separation as cyanide.

  6. SHEAR STRENGTH IN THE GLUE LINE OF Eucalyptus sp. AND Pinus sp.WOOD

    Directory of Open Access Journals (Sweden)

    Juliana Jerásio Bianche

    Full Text Available ABSTRACT To evaluate the adhesive efficiency on the union of glued joints in a particular temperature and humidity conditions for a specified time the adhesive must be submitted to specific load tests, such as shear in the glue line. The objective of this study was to evaluate the shear strength in the glue line of Eucalyptus sp and Pinus sp.woods. Five adhesives (castor oil, sodium silicate, modified silicate, , PVA and resorcinol-formaldehyde, three weights (150 g/m2, 200 g/m2, and 250 g/m2 and two species (Eucalyptus sp. and Pinus sp. of wood were used. Twelve specimens were obtained from each repetition per treatment, corresponding to 108 specimens that were conditioned at a temperature of 23 ± 1°C and relative humidity of 50 ± 2%. The interaction between the weight and type of adhesive was significant for the shear strength in the glue line of eucalyptus wood. However, no interaction between the weight and the adhesive was found for pinus, only the isolated from the adhesive effect. Chemical bonds originated in the polymerization of resorcinol-formaldehyde adhesives and castor bi-component conferred upon these adhesives the greatest resistance in the glue line. Castor and resorcinol-formaldehyde adhesives showed the highest shear strength values in the line of glue and wood failure. Castor adhesive presented satisfactory performance for bonding of eucalyptus and pine woods.

  7. Clinical and morphological evaluation of snake venom derived fibrin glue on the tendon healing in dogs

    Directory of Open Access Journals (Sweden)

    G. C. Ferraro

    2005-12-01

    Full Text Available The aim of this study was to evaluate the effect of snake venom derived fibrin glue on the healing of the deep digital flexor tendon, during three periods. The tendon of the 2nd digit of 30 thoracic limbs of dogs was partially sectioned for glue application. Biopsies were performed 7, 15, and 30 days post surgery for the clinical and morphological study of tendons. Analysis of the results showed that 73.3% of the tendons showed stump retraction and 16.6% moderate to excessive adherence, which affected sliding. There was a significant difference in the number of inflammatory cells among the three studied periods, being the highest on day 15. The morphological analysis revealed a typical tendon healing process with a lower level of inflammation in the acute phase, facilitating the cicatricial maturation phase. Snake venom derived fibrin glue promotes the healing in dog flexor tendon.

  8. Photoclickable dendritic molecular glue: noncovalent-to-covalent photochemical transformation of protein hybrids.

    Science.gov (United States)

    Uchida, Noriyuki; Okuro, Kou; Niitani, Yamato; Ling, Xiao; Ariga, Takayuki; Tomishige, Michio; Aida, Takuzo

    2013-03-27

    A water-soluble dendron with a fluorescein isothiocyanate (FITC) fluorescent label and bearing nine pendant guanidinium ion (Gu(+))/benzophenone (BP) pairs at its periphery (Glue(BP)-FITC) serves as a "photoclickable molecular glue". By multivalent salt-bridge formation between Gu(+) ions and oxyanions, Glue(BP)-FITC temporarily adheres to a kinesin/microtubule hybrid. Upon subsequent exposure to UV light, this noncovalent binding is made permanent via a cross-linking reaction mediated by carbon radicals derived from the photoexcited BP units. This temporal-to-permanent transformation by light occurs quickly and efficiently in this preorganized state, allowing the movements of microtubules on a kinesin-coated glass plate to be photochemically controlled. A fundamental difference between such temporal and permanent bindings was visualized by the use of "optical tweezers".

  9. Using the DP-190 glue for adhesive attachment of a large space mirror and its rim

    Science.gov (United States)

    Vlasenko, Oleg; Zverev, Alexey; Sachkov, Mikhail

    2014-07-01

    The glue DP-190 is widely used for adhesive attachment of astrositall (zerodur) lightweight large-size space astronomical mirrors (diameter of 1.7 m and more) with elements of their frames of invar. Peculiarities of physicalmechanical behavior of the glue DP-190 when exposed to the environment during the ground operation and in orbit cause instability of the reflective surface quality of mirrors. In this report we show that even a small (around 1%-5%) volumetric deformation of a cylindrical adhesive layer with a thickness of 0.8 mm between the mirror and the rim element causes significant mirrors deformation. We propose to use adhesive layer of special form that allows to reduce volumetric deformations of the glue DP-190 up to three times. Here we present results based on primary mirror tests of the WSO-UV project.

  10. Clinical experience of intrapleural administration of fibrin glue for secondary pneumothorax with advanced lung cancer

    International Nuclear Information System (INIS)

    Nishino, Takeshi; Takizawa, Hiromitsu; Yoshida, Mitsuteru; Kawakami, Yukikiyo; Sakiyama, Shoji; Kondo, Kazuya

    2014-01-01

    Secondary pneumothorax with advanced lung cancer is an intractable and serious pathosis, which directly aggravates patients' Quality of Life (QOL) and prognosis. We first select the intrapleural administration of fibrin glue for secondary pneumothorax with advanced lung cancer. From April 2009 to May 2012, we encountered 5 patients who developed secondary pneumothorax during treatment for advanced lung cancer. Their average age was 60.8 years old, and 4 of them had squamous cell carcinoma, 1 had adenocarcinoma, and all had unresectable advanced lung cancer. In 4 of them, the point of air leakage could be detected by pleurography, and leakage could be stopped by the intrapleural administration of fibrin glue. All of them could receive chemotherapy or radiotherapy after treatment for secondary pneumothorax. The intrapleural administration of fibrin glue may be an effective and valid treatment for intractable secondary pneumothorax with advanced lung cancer. (author)

  11. Successful Endoscopic Management of Non-Healing Perforated Duodenal Ulcer with Polyglycolic Acid Sheet and Fibrin Glue.

    Science.gov (United States)

    Mishiro, Tsuyoshi; Shibagaki, Kotaro; Matsuda, Kayo; Fukuyama, Chika; Okada, Mayumi; Mikami, Hironobu; Izumi, Daisuke; Yamashita, Noritsugu; Okimoto, Eiko; Fukuda, Naoki; Aimi, Masahito; Fukuba, Nobuhiko; Oshima, Naoki; Takanashi, Toshihiro; Matsubara, Takeshi; Ishimura, Norihisa; Ishihara, Shunji; Kinoshita, Yoshikazu

    2016-08-01

    In recent years, treatment techniques in which polyglycolic acid sheets are applied to various situations with fibrin glue have exhibited great clinical potential, and previous studies have reported safety and efficacy. We describe closure of a non-healing perforated duodenal ulcer with the use of a polyglycolic acid sheet and fibrin glue in an elderly patient who was not a candidate for surgery.

  12. Determination of fibrin glue with antibiotics on collagen production in colon anastomosis

    Directory of Open Access Journals (Sweden)

    Stanojković Zoran

    2008-01-01

    Full Text Available Background/Aim. Fibrin glue is used as a matrix for local application of antibiotics. The aim of this study was to determine whether application of fibrin glue in combination with antibiotics can strengthen collagen production, prevent dehiscence of colon anastomoses due to infection, and reduce frequency of mortality and morbidity comparing to the control group and the group with fibrin glue application. Methods. The adult male Wistar rats divided into three groups were used in the experiment. The group 1 was the control one (after partial colon resection, colonic anastomoses performed were not treated, while to the group 2 and the group 3 were applied fibrin glue and fibrin glue with antibiotics (clindamycin and ceftriaxon on the site of anastomoses, respectively. Quality of colonic anastomoses were estimated by means of determination of collagen (L-hydroxyproline amount in the collon wall with anastomoses and histological analysis of this colon segment using light and electronic microscope on the days 5, 7 and 13 postoperatively. Results. The highest morbidity rate was registered in the group 1 (30%, then in the group 2 (13.3% and the lowest one in the group 3 (3.33%; p < 0,05 vs group 1. Mortality rate was significantly higher in the group 1 than in the group 3 (20% and 0%, respectively; p < 0,05. In the postoperative course, the highest concentrations of collagen in the colon wall on the site of anastomoses, which was confirmed by both light and electronic microscopy, were found in the group 3. Conclusion. The application of fibrin glue with antibiotics on colon anastomoses reduces the number of dehiscence, provides good mechanical protection and shorten the time of anastomoses healing.

  13. BioGlue iceball stabilization to minimize the risk of hemorrhage during laparoscopic renal cryoablation.

    Science.gov (United States)

    Mues, Adam C; Graversen, Joseph A; Truesdale, Matthew D; Casazza, Cristin; Landman, Jaime

    2011-08-01

    To evaluate the application of a BioGlue adhesive shell to minimize iceball fracture. Iceball fracture and hemorrhage is common with laparoscopic cryoablation (LCA) of larger (>4 cm) renal tumors. Twenty large iceballs were created in porcine kidneys using 3 cryoablation probes in a nonsurvival study. Each kidney underwent an upper and lower pole ablation. One pole in each kidney was covered with 5 mL of BioGlue and the opposite pole served as a control. A double freeze-thaw cycle was performed (10 minutes freeze and 5 minutes active thaw) in both renal poles simultaneously. The probes were removed and the sites were monitored for 20 minutes under direct vision. Fracture length (mm), severity of fracture depth, severity of bleeding (absent, mild, moderate, severe), and estimated blood loss (EBL) (mL) were recorded. In the control group, the mean fracture length was 1.9 mm (range, 0-3 mm). Blood loss was absent in 10%, mild in 60%, and moderate in 30% of ablations. The mean EBL was 20.5 mL (range, 0-50 mL). For the BioGlue ablations, there were no parenchymal fractures. Blood loss was mild in 30% and absent in 70% of sites with an average EBL of 5 mL (range, 0-20). Two bleeding sites occurred as a result of subcapsular hematomas caused by initial probe placement. BioGlue application minimized the frequency and magnitude of renal fracture. EBL was lower with BioGlue application and most sites demonstrated no postablation bleeding. Further clinical study of the BioGlue shell should be performed to confirm these results. Copyright © 2011 Elsevier Inc. All rights reserved.

  14. GLUE 2 deployment: Ensuring quality in the EGI/WLCG information system

    International Nuclear Information System (INIS)

    Burke, Stephen; Pradillo, Maria Alandes; Field, Laurence; Keeble, Oliver

    2014-01-01

    The GLUE 2 information model is now fully supported in the production EGI/WLCG information system. However, to make it usable and allow clients to rely on the published information it is important that the meaning is clearly defined, and that information providers and site configurations are validated to ensure as far as possible that what they publish is correct. In this paper we describe the definition of a detailed schema usage profile, the implementation of a software tool to validate published information according to the profile and the use of the tool in the production Grid, and also summarise the overall state of GLUE 2 deployment.

  15. Glue from the Sea:Biomedical Adhesives Inspired by Algal Polymers

    Institute of Scientific and Technical Information of China (English)

    H.Bianco-Peled; R.Bitton; P.Potin

    2007-01-01

    1 Introduction Tissue repair following surgery or trauma has been dominated by sutures,staples and wiring.Although these techniques are well established and widely used,their application often involves pain,unaesthetic results,or bleeding. These limitations emphasize the need for adhesive products to be available to surgeons.2 ResultsA challenging aspect of developing new tissue adhesive is to create a material that can glue wet surfaces.The success of synthetic glues under such an environment is very ...

  16. Nuovi Metodi di visualizzazione geografica: l'approccio Focus+Glue+Context

    Directory of Open Access Journals (Sweden)

    Flavio Lupia

    2010-03-01

    Full Text Available New cartographic visualization methods:the Focus+Glue+Context approachFocus+Glue+Context is a new cartographic visualization method specifically designed to solve the fruition problems connected with the use of mobile devices and web mapping services. The objective of the F+G+C approach is to reduce users cognitive efforts when reading a map: to do so, the area of interest is ‘highlighted’ in a lower and more detailed scale through a fisheye lens effect, while the sorrouding context, useful to the user to determine the items relationships in a map, is maintained on a higher scale.

  17. Nuovi Metodi di visualizzazione geografica: l'approccio Focus+Glue+Context

    Directory of Open Access Journals (Sweden)

    Flavio Lupia

    2010-03-01

    Full Text Available New cartographic visualization methods: the Focus+Glue+Context approach Focus+Glue+Context is a new cartographic visualization method specifically designed to solve the fruition problems connected with the use of mobile devices and web mapping services. The objective of the F+G+C approach is to reduce users cognitive efforts when reading a map: to do so, the area of interest is ‘highlighted’ in a lower and more detailed scale through a fisheye lens effect, while the sorrouding context, useful to the user to determine the items relationships in a map, is maintained on a higher scale.

  18. Bandwidth-Tunable Fiber Bragg Gratings Based on UV Glue Technique

    Science.gov (United States)

    Fu, Ming-Yue; Liu, Wen-Feng; Chen, Hsin-Tsang; Chuang, Chia-Wei; Bor, Sheau-Shong; Tien, Chuen-Lin

    2007-07-01

    In this study, we have demonstrated that a uniform fiber Bragg grating (FBG) can be transformed into a chirped fiber grating by a simple UV glue adhesive technique without shifting the reflection band with respect to the center wavelength of the FBG. The technique is based on the induced strain of an FBG due to the UV glue adhesive force on the fiber surface that causes a grating period variation and an effective index change. This technique can provide a fast and simple method of obtaining the required chirp value of a grating for applications in the dispersion compensators, gain flattening in erbium-doped fiber amplifiers (EDFAs) or optical filters.

  19. Photocurable surgical tissue adhesive glues composed of photoreactive gelatin and poly(ethylene glycol) diacrylate.

    Science.gov (United States)

    Nakayama, Y; Matsuda, T

    1999-01-01

    This article presents a novel photochemically driven surgical tissue adhesive technology using photoreactive gelatins and a water-soluble difunctional macromer (poly(ethylene glycol) diacrylate: PEGDA).The gelatins were partially derivatized with photoreactive groups, such as ultraviolet light (UV)-reactive benzophenone and visible light-reactive xanthene dye (e.g., fluorescein sodium salt, eosin Y, and rose bengal). A series of the prepared photocurable tissue adhesive glues, consisting of the photoreactive gelatin, PEGDA, and a saline solution with or without ascorbic acid as a reducing agent, were viscous solutions under warming, and their effectiveness was evaluated as hemostasis- and anastomosis-aid in cardiovascular surgery. Regardless of the type of photoreactive groups, the irradiation of the photocurable tissue adhesive glues by UV or visible light within 1 min produced water-swollen gels, which had a high adhesive strength to wet collagen film. These were due to the synergistic action of photoreactive group-initiated photo-cross-linking and photograft polymerization. An increase in the irradiation time resulted in increased gel yield and reduced water swellability. A decrease in the molecular weight of PEGDA and an increase in concentration of both gelatin and PEGDA resulted in reduced water swellability and increased tensile and burst strengths of the resultant gels. In rats whose livers were injured with a trephine in laparotomy, the bleeding spots were coated with the photocurable adhesive glue and irradiated through an optical fiber. The coated solution was immediately converted to a swollen gel. The gel was tightly adhered to the liver tissue presumably by interpenetration, and concomitantly hemostasis was completed. The anastomosis treatment with the photocurable glue in the canine abdominal or thoracic aortas incised with a knife resulted in little bleeding under pulsatile flow after declamping. Histological examination showed that the glues

  20. Effect of BioGlue on the incidence of pancreatic fistula following pancreas resection.

    Science.gov (United States)

    Fisher, William E; Chai, Christy; Hodges, Sally E; Wu, Meng-Fen; Hilsenbeck, Susan G; Brunicardi, F Charles

    2008-05-01

    Despite numerous modifications of surgical technique, pancreatic fistula remains a serious problem and occurs in about 10% of patients following pancreas resection. BioGlue is a new sealant that creates a flexible mechanical seal within minutes independent of the body's clotting mechanism. Application of BioGlue sealant will reduce the incidence of pancreatic fistula following pancreas resection. A retrospective cohort study was performed with 64 patients undergoing pancreas resection. BioGlue sealant was applied to the pancreatic anastomosis (Whipple) or resection margin (distal pancreatectomy) in 32 cases. Factors that could affect the rate of postoperative pancreatic fistula were recorded. Pancreatic fistula was defined as greater than 50 ml of drain output with an amylase content greater than three times normal serum value after postoperative day 10. To improve the sensitivity of our study, we also examined pancreatic fistula with a strict definition of any drain output on or after postoperative day 3 with a high amylase content and graded the fistulas in terms of clinical severity. Grade A leaks were defined as subclinical. Grade B leaks required some response such as making the patient nil per os, parenteral nutrition, octreotide, antibiotics, or a prolonged hospital stay. Grade C leaks were defined as serious and life threatening. They were associated with hemorrhage, sepsis, resulted in deterioration of other organ systems, and mandated intensive care. Comparisons between the two groups were made using the chi-square test or Fisher's exact test for categorical variables and by the Wilcoxon rank-sum test for continuous variables. P values of 0.05 or less were deemed statistically significant. There were no differences between the patients who received BioGlue and the control cohort in terms of comorbid conditions, tumor location, texture of the pancreas, size of the pancreatic duct, or surgical technique. By the common definition, pancreatic fistula occurred

  1. Comparative uncertainty analysis of copper loads in stormwater systems using GLUE and grey-box modeling

    DEFF Research Database (Denmark)

    Lindblom, Erik Ulfson; Madsen, Henrik; Mikkelsen, Peter Steen

    2007-01-01

    . With the proposed model and input data, the GLUE analysis show that the total sampled copper mass can be predicted within a range of +/- 50% of the median value ( 385 g), whereas the grey-box analysis showed a prediction uncertainty of less than +/- 30%. Future work will clarify the pros and cons of the two methods...

  2. Performance of fast-absorbable suture and histo-glue in closing incisions in Brown trout

    DEFF Research Database (Denmark)

    Jepsen, Niels; Larsen, Martin Hage; Aarestrup, Kim

    2017-01-01

    , growth, tag expulsion rate and incision healing was compared among three groups of dummy transmitter-tagged wild brown trout Salmo trutta where incisions were closed with two types of suture material (absorbable vs. fast absorbable) and Histo-glue. The tagged fish were kept in semi-natural ponds for 20...

  3. GLUE Based Uncertainty Estimation of Urban Drainage Modeling Using Weather Radar Precipitation Estimates

    DEFF Research Database (Denmark)

    Nielsen, Jesper Ellerbæk; Thorndahl, Søren Liedtke; Rasmussen, Michael R.

    2011-01-01

    Distributed weather radar precipitation measurements are used as rainfall input for an urban drainage model, to simulate the runoff from a small catchment of Denmark. It is demonstrated how the Generalized Likelihood Uncertainty Estimation (GLUE) methodology can be implemented and used to estimate...

  4. Magnetic Retraction of Bowel by Intraluminal Injectable Cyanoacrylate-Based Magnetic Glue

    Directory of Open Access Journals (Sweden)

    Zhigang Wang

    2013-01-01

    Full Text Available Magnetic retraction offers advantages over physical retraction by graspers because of reduced tissue trauma. The objectives of this study are to investigate a novel method of magnetisation of bowel segments by intraluminal injection of magnetic glue and to demonstrate the feasibility of magnetic retraction of bowel with sufficient force during minimal access surgery. Following an initial materials characterisation study, selected microparticles of stainless steel (SS410-μPs were mixed with chosen cyanoacrylate glue (Loctite 4014. During intraluminal injection of the magnetic glue using ex vivo porcine colonic segments, a magnetic probe placed at the injected site ensured that the SS410-μPs aggregated during glue polymerisation to form an intraluminal mucosally adherent coagulum. The magnetised colonic segments were retracted by magnetic probes (5 and 10 mm placed external to the bowel wall. A tensiometer was used to record the retraction force. With an injected volume of 2 mL in a particle concentration of 1 g/mL, this technique produced maximal magnetic retraction forces of 2.24 ± 0.23 N and 5.11 ± 0.34 N (, with use of 5 and 10 mm probes, respectively. The results indicate that the formation of an intraluminal coagulum based on SS410-μPs and Loctite 4014 produces sufficient magnetic retraction for bowel retraction.

  5. Glue-Sniffing: A Comparison Study of Sniffers and Non-Sniffers.

    Science.gov (United States)

    Jansen, P.; And Others

    1992-01-01

    Compared 22 glue sniffers and 22 nonsniffers from group of street children and adolescents living in supervised shelters. Found no statistically significant differences between groups on cognitive measures or biographical features. Shelter staff rated sniffers as significantly more disturbed in their relationships with others, although…

  6. A unique and unexplained ricochet leak post PCI – Successfully treated with intra-coronary glue

    Directory of Open Access Journals (Sweden)

    Pravin K. Goel

    2014-01-01

    Full Text Available We herein describe a unique case of coronary artery perforation treated with covered stent with repeat cardiac tamponade resulting out of a fresh unexplained leak from a remote vessel (Ricochet and successfully treated with intra-coronary injection of sterile synthetic glue, cyanoacrylate.

  7. Histological assessment of titanium and polypropylene fiber mesh implantation with and without fibrin tissue glue.

    NARCIS (Netherlands)

    Hallers, E.J.O. ten; Jansen, J.A.; Marres, H.A.M.; Rakhorst, G.; Verkerke, G.J.

    2007-01-01

    Polypropylene (PP) and titanium (Ti) meshes are well-known surgical implants that provoke a relative low foreign body reaction. Firm stabilization of the implant is important to prevent migration and subsequent failure of the operation. Fibrin tissue glues are commercially available adhesives and

  8. Histological assessment of titanium and polypropylene fiber mesh implantation with and without fibrin tissue glue

    NARCIS (Netherlands)

    ten Hallers, E.J. Olivier; Jansen, John A.; Marres, Henri A.M.; Rakhorst, Gerhard; Verkerke, Gijsbertus Jacob

    2007-01-01

    Polypropylene (PP) and titanium (Ti) meshes are well-known surgical implants that provoke a relative low foreign body reaction. Firm stabilization of the implant is important to prevent migration and subsequent failure of the operation. Fibrin tissue glues are commercially available adhesives and

  9. Histological assessment of titanium and polypropylene fiber mesh implantation with and without fibrin tissue glue

    NARCIS (Netherlands)

    ten Hallers, E. J. Olivier; Jansen, John A.; Marres, Henri A. M.; Rakhorst, Gerhard; Verkerke, Gijsbertus J.

    Polypropylene (PP) and titanium (Ti) meshes are well-known surgical implants that provoke a relative low foreign body reaction. Firm stabilization of the implant is important to prevent migration and subsequent failure of the operation. Fibrin tissue glues are commercially available adhesives and

  10. Coronary artery narrowing after aortic root reconstruction with resorcin-formalin glue.

    Science.gov (United States)

    Martinelli, L; Graffigna, A; Guarnerio, M; Bonmassari, R; Disertori, M

    2000-11-01

    Severe stenosis of right and left main coronary artery ostia developed after aortic root reconstruction with gelatin-resorcin-formol glue for correction of acute type A aortic dissection. Surgical treatment of this condition required grafting of the right and left anterior descending arteries with bilateral mammary arteries on the beating heart.

  11. Photoinduced Bioorthogonal 1,3-Dipolar Poly-cycloaddition Promoted by Oxyanionic Substrates for Spatiotemporal Operation of Molecular Glues.

    Science.gov (United States)

    Hatano, Junichi; Okuro, Kou; Aida, Takuzo

    2016-01-04

    PGlue(PZ), a pyrazoline (PZ)-based fluorescent adhesive which can be generated spatiotemporally in living systems, was developed. Since PGlue(PZ) carries many guanidinium ion (Gu(+)) pendants, it strongly adheres to various oxyanionic substrates through a multivalent salt-bridge interaction. PGlue(PZ) is given by bioorthogonal photopolymerization of a Gu(+)-appended monomer (Glue(TZ)), bearing tetrazole (TZ) and olefinic termini. Upon exposure to UV light, Glue(TZ) transforms into a nitrileimine (NI) intermediate (Glue(NI)), which is eligible for 1,3-dipolar polycycloaddition. However, Glue(NI) in aqueous media can concomitantly be deactivated into Glue(WA) by the addition of water, and the polymerization hardly occurs unless Glue(NI) is concentrated. We found that, even under high dilution, Glue(NI) is concentrated on oxyanionic substrates to a sufficient level for the polymerization, so that their surfaces can be point-specifically functionalized with PGlue(PZ) by the use of a focused beam of UV light. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Physicochemical and functional properties, microstructure, and storage stability of whey protein/polyvinylpyrrolidone based glue sticks

    Directory of Open Access Journals (Sweden)

    Guorong Wang

    2012-11-01

    Full Text Available A glue stick is comprised of solidified adhesive mounted in a lipstick-like push-up tube. Whey is a byproduct of cheese making. Direct disposal of whey can cause environmental pollution. The objective of this study was to use whey protein isolate (WPI as a natural polymer along with polyvinylpyrrolidone (PVP to develop safe glue sticks. Pre-dissolved WPI solution, PVP, sucrose, 1,2-propanediol (PG, sodium stearate, defoamer, and preservative were mixed and dissolved in water at 90 oC and then molded in push-up tubes. Chemical composition, functional properties (bonding strength, glue setting time, gel hardness, extension/retraction, and spreading properties, microstructure, and storage stability of the prototypes were evaluated in comparison with a commercial control. Results showed that all WPI/PVP prototypes had desirable bonding strength and exhibited faster setting than PVP prototypes and control. WPI could reduce gel hardness and form less compact and rougher structures than that of PVP, but there was no difference in bonding strength. PVP and sucrose could increase the hygroscopicity of glue sticks, thus increasing storage stability. Finally, the optimized prototype GS3 (major components: WPI 8.0%, PVP 12.0%, 1,2-propanediol 10.0%, sucrose 10.0%, and stearic sodium 7.0% had a comparable functionality to the commercial control. Results indicated that whey protein could be used as an adhesive polymer for glue stick formulations, which could be used to bond fiber or cellulose derived substrates such as paper.

  13. Cross-linking by protein oxidation in the rapidly setting gel-based glues of slugs

    Science.gov (United States)

    Bradshaw, Andrew; Salt, Michael; Bell, Ashley; Zeitler, Matt; Litra, Noelle; Smith, Andrew M.

    2011-01-01

    SUMMARY The terrestrial slug Arion subfuscus secretes a glue that is a dilute gel with remarkable adhesive and cohesive strength. The function of this glue depends on metals, raising the possibility that metal-catalyzed oxidation plays a role. The extent and time course of protein oxidation was measured by immunoblotting to detect the resulting carbonyl groups. Several proteins, particularly one with a relative molecular mass (Mr) of 165×103, were heavily oxidized. Of the proteins known to distinguish the glue from non-adhesive mucus, only specific size variants were oxidized. The oxidation appears to occur within the first few seconds of secretion. Although carbonyls were detected by 2,4-dinitrophenylhydrazine (DNPH) in denatured proteins, they were not easily detected in the native state. The presence of reversible cross-links derived from carbonyls was tested for by treatment with sodium borohydride, which would reduce uncross-linked carbonyls to alcohols, but stabilize imine bonds formed by carbonyls and thus lead to less soluble complexes. Consistent with imine bond formation, sodium borohydride led to a 20–35% decrease in the amount of soluble protein with a Mr of 40–165 (×103) without changing the carbonyl content per protein. In contrast, the nucleophile hydroxylamine, which would competitively disrupt imine bonds, increased protein solubility in the glue. Finally, the primary amine groups on a protein with a Mr of 15×103 were not accessible to acid anhydrides. The results suggest that cross-links between aldehydes and primary amines contribute to the cohesive strength of the glue. PMID:21525316

  14. Fibrin glue on an aortic cusp detected by transesophageal echocardiography after valve-sparing aortic valve replacement: a case report.

    Science.gov (United States)

    Nakahira, Junko; Ishii, Hisanari; Sawai, Toshiyuki; Minami, Toshiaki

    2015-03-07

    Fibrin glue is used commonly during cardiac surgery but can behave as an intracardiac abnormal foreign body following surgery. There have been few such cases reported, and they were typically noticed only because of the resulting catastrophic cardiac conditions, such as valvular malfunction. We report a case where, for the first time, transesophageal echocardiography was used to detected fibrin glue that was adherent to the ventricular side of a patient's aortic valve immediately after aortic declamping. A 45-year-old Japanese man with Marfan syndrome underwent an aortic valve-sparing operation to treat moderate aortic valve regurgitation resulting from enlargement of his right coronary cusp. Fibrin glue was lightly applied to the suture line between the previous and new grafts. Transesophageal echocardiography performed prior to weaning from the cardiopulmonary bypass revealed mild aortic valve regurgitation in addition to a mobile membranous structure attached to the ventricular side of his aortic valve. It was identified as fibrin glue. We resolved the regurgitation by removing the fibrin glue and repeating the aortic cusp plication. The patient had no complications during recovery. Fibrin glue can act as an intracardiac foreign body and lead to a potentially fatal embolism. We demonstrated the use of transesophageal echocardiography to detect a fibrin glue-derived intracardiac abnormal foreign body and to confirm its removal. To the best of our knowledge, this is the first case where fibrin glue adherent to the aortic valve was detected by transesophageal echocardiography. These findings demonstrate the importance of using transesophageal echocardiography during cardiac surgery that involves using biological glues.

  15. Hypokalemic muscular paralysis causing acute respiratory failure due to rhabdomyolysis with renal tubular acidosis in a chronic glue sniffer.

    Science.gov (United States)

    Kao, K C; Tsai, Y H; Lin, M C; Huang, C C; Tsao, C Y; Chen, Y C

    2000-01-01

    A 34-year-old male was admitted to the emergency department with the development of quadriparesis and respiratory failure due to hypokalemia after prolonged glue sniffing. The patient was subsequently given mechanical ventilatory support for respiratory failure. He was weaned from the ventilator 4 days later after potassium replacement. Toluene is an aromatic hydrocarbon found in glues, cements, and solvents. It is known to be toxic to the nervous system, hematopoietic system, and causes acid-base and electrolyte disorders. Acute respiratory failure with hypokalemia and rhabdomyolysis with acute renal failure should be considered as potential events in a protracted glue sniffing.

  16. Experimental closure of gunshot wounds by fibrin glue with antibiotics in pigs

    Directory of Open Access Journals (Sweden)

    Đenić Nebojša

    2015-01-01

    Full Text Available Background/Aim. Gunshot wounds caused by the automatic rifle M70AB2 (AK-47 7.62 mm, after the primary surgical management, were closed with delayed primary suture during the next four to seven days. This period coincides with the fibroblastic phase of wound healing. Fibrin glue is used as a local hemostatic and as a matrix for the local dosed release of antibiotics. Antibiotics addition to fibrin glue resulted in continuous diffusion into the surrounding next 4 to 7 days. The aim of this study was to create the preconditions for gunshot wounds closing without complications by the application of fibrin glue with antibiotics 24 h after primary surgical treatment. Methods. A total of 14 pigs were wounded in the gluteofemoral region by the bullet M67, initial velocity of 720 m/s. All wounded animals were surgically treated according to the principles of the warsurgery doctrine. Seven wounds were closed with primary delayed suture four days after the primary surgical treatment (traditional approach. Fibrin glue with antibiotics was introduced in seven wounds during the primary surgical treatment and primary delayed suture was done after 24 h. The macroscopic appearance and the clinical assessment of the wound were done during the primary surgical treatment and during its revision after 24 h, as well as histopathological findings at the days 4 and 7 after wounding. Results. Gunshot wounds caused by the automatic rifle M70AB2 (AK-47 7.62 mm, and treated with fibrin glue with antibiotics after primary surgical management, were closed with primary delayed suture after 24 h. In further wound evolution there were no complications. Conclusion. Uncomplicated soft-tissue wounds caused by an automatic M70AB2 rifle may be closed primarily with delayed suture without the risk of developing complications if on revision, 24 h after primary surgery, there were no present necrotic tissues, hematoma, and any signs of infection when fibrin glue with antibiotics

  17. Preoperative embolization of nasopharyngeal angiofibromas: The role of direct percutaneous injection of cyanoacrylate glue in conjunction with particulate endovascular approach

    Directory of Open Access Journals (Sweden)

    Mohamed Abdel Hakim Osman Kasem

    2016-12-01

    Conclusion: The embolization of nasopharyngeal angiofibromas before surgery using percutaneous cyanoacrylate glue with endovascular particulate material proved to efficiently devascularize these tumours with lower blood loss during surgery and no major procedural complications.

  18. Development of Silicon Photomultipliers and their Applications to GlueX Calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Elton S. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2016-07-01

    The GlueX experiment is a photoproduction experiment in Hall D at Jefferson Lab that is being commissioned for use with the new 12 GeV accelerator. The purpose of the experiment is to search for Hybrid mesons, which are mesons with quark and gluon degrees of freedom. The barrel calorimeter of GlueX is instrumented with 4000 large-area (1.2 x1.2 cm2) silicon photomultipliers (SiPMs). These photon sensors have properties similar to vacuum photomultipliers, but are unaffected by high magnetic fields. In our experiment they operate in magnetic fields exceeding 1T. After extensive tests with a variety of sensors, we chose the S12045(X) custom SiPM arrays manufactured by Hamamatsu Corporation, also known as multi-pixel photon counters (MPPCs). We will give an overview of this new technology as well as the experience gained during two commissioning periods with beam.

  19. Endoluminal embolization of bilateral atherosclerotic common iliac aneurysms with fibrin tissue glue (Beriplast)

    International Nuclear Information System (INIS)

    Beese, Richard C.; Tomlinson, Mark A.; Buckenham, Timothy M.

    2000-01-01

    The standard surgical approach to nonleaking iliac aneurysms found at repair of a leaking abdominal aortic aneurysm is to minimize the operative risk by repairing the abdominal aorta only. This means that the bypassed iliac aneurysms may have to be repaired later. As this population of patients are usually elderly with coexisting medical problems, interventional radiology is being used to embolize these aneurysms, thus avoiding the morbidity and mortality associated with further general anesthesia and surgery. Various materials and stents have been reported to be effective in the treatment of iliac aneurysms. We report the successful use of endoluminal fibrin tissue glue (Beriplast) to treat two large iliac aneurysms in a patient who had had a previous abdominal aortic aneurysm repair. We discuss the technique involved and the reasons why we used tissue glue in this patient.

  20. Endoscopic use of cyanoacrylate glue in the treatment of urethral fistula

    Directory of Open Access Journals (Sweden)

    Andre Ramos Sorgi Macedo

    2013-07-01

    Full Text Available Purpose The aim of this video is to demonstrate an endoscopic and minimally invasive repair of an urethrocutaneous fistula with cyanoacrylate glue. Materials and Methods: A 56 year-old-man with post-infectious urethral stricture and recurrent perineal abscess formation due to urethral fistulas. Results The operative time was 60 minutes, no major complications were observed perioperatively and postoperatively. At a follow-up time of 6 months the patient had no evidence of recurrent fistula and abscess formation. CONCLUSIONS The endoscopic use of cyanoacrylate glue represents a safe and minimally invasive approach that might be offered as a first line option for the treatment of urinary fistulas in selected patients, especially those with narrow and long tracts.

  1. Percutaneous sclerotherapy of sialoceles after parotidectomy with fibrin glue, OK-432, and bleomycin.

    Science.gov (United States)

    Chen, Wei-liang; Zhang, Li-ping; Huang, Zhi-quan; Zhou, Bin

    2013-12-01

    We evaluated the curative effect of fibrin glue combined with OK-432 (streptococcal pyrogenic exotoxin A, Picibanil™) and bleomycin on 9 patients with sialoceles after parotidectomy. The primary lesions included pleomorphic adenomas in 6 cases and Warthin's tumours in 3 cases. After a sialocele had been diagnosed each patient had repeated aspirations and pressure dressings for 3-4 weeks, but these treatments failed. The patients were then treated with percutaneous sclerotherapy with the injection of fibrin glue 8-10 ml combined with OK-432 5 mg and bleomycin 15 mg. All the sialoceles disappeared completely after a single procedure in 2-3 weeks. The patients have been followed up for more than 6 months with no evidence of recurrent sialocele or injury to the facial nerve related to sclerotherapy. This simple, safe technique can be successfully used to treat sialoceles after parotidectomy. Copyright © 2013 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  2. Development of silicon photomultipliers and their applications to GlueX calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Elton S., E-mail: elton@jlab.org [Jefferson Lab, Newport News, VA 23606 (United States)

    2016-07-07

    The GlueX experiment is a photoproduction experiment in Hall D at Jefferson Lab that is being commissioned for use with the new 12 GeV accelerator. The purpose of the experiment is to search for Hybrid mesons, which are mesons with quark and gluon degrees of freedom. The barrel calorimeter of GlueX is instrumented with 4000 large-area (1.2 × 1.2 cm{sup 2}) silicon photomultipliers (SiPMs). These photon sensors have properties similar to vacuum photomultipliers, but are unaffected by high magnetic fields. In our experiment they operate in magnetic fields exceeding 1T. After extensive tests with a variety of sensors, we chose the S12045(X) custom SiPM arrays manufactured by Hamamatsu Corporation, also known as multi-pixel photon counters (MPPCs). We will give an overview of this new technology as well as the experience gained during two commissioning periods with beam.

  3. Generalized likelihood uncertainty estimation (GLUE) using adaptive Markov chain Monte Carlo sampling

    DEFF Research Database (Denmark)

    Blasone, Roberta-Serena; Vrugt, Jasper A.; Madsen, Henrik

    2008-01-01

    propose an alternative strategy to determine the value of the cutoff threshold based on the appropriate coverage of the resulting uncertainty bounds. We demonstrate the superiority of this revised GLUE method with three different conceptual watershed models of increasing complexity, using both synthetic......In the last few decades hydrologists have made tremendous progress in using dynamic simulation models for the analysis and understanding of hydrologic systems. However, predictions with these models are often deterministic and as such they focus on the most probable forecast, without an explicit...... of applications. However, the MC based sampling strategy of the prior parameter space typically utilized in GLUE is not particularly efficient in finding behavioral simulations. This becomes especially problematic for high-dimensional parameter estimation problems, and in the case of complex simulation models...

  4. Role of cyanoacrylate glue therapy in enteral SEMS bleeding - A nightmare

    Directory of Open Access Journals (Sweden)

    Virukalpatti Goparathinam Mohanprasad

    2013-01-01

    Full Text Available Over the past century, the use of stents has evolved to a point where they are now used extensively throughout the gastrointestinal tract. Endoscopic stenting has become widely used for treatment of gastrointestinal and hepatobiliary strictures. Metallic stents are deployed in malignant strictures as a palliative procedure. Adverse events of stenting include perforation, migration, bleeding, occlusion, and pain. Finally, the use of multidisciplinary teams which include endoscopists, interventional radiologists, and surgeons allows for the exchange of ideas and procedural planning necessary for successful innovation. We present a case of successful cessation of bleeding by using cyanoacrylate glue therapy in post-enteral self-expandable metallic stent bleeding. In conclusion, glue therapy may also be considered as a mode of treatment other than conservative approach and angiographic coil embolization.

  5. Determining characteristic principal clusters in the “cluster-plus-glue-atom” model

    International Nuclear Information System (INIS)

    Du, Jinglian; Wen, Bin; 2NeT Lab, Wilfrid Laurier University, Waterloo, 75 University Ave West, Ontario N2L 3C5 (Canada))" data-affiliation=" (M2NeT Lab, Wilfrid Laurier University, Waterloo, 75 University Ave West, Ontario N2L 3C5 (Canada))" >Melnik, Roderick; Kawazoe, Yoshiyuki

    2014-01-01

    The “cluster-plus-glue-atom” model can easily describe the structure of complex metallic alloy phases. However, the biggest obstacle limiting the application of this model is that it is difficult to determine the characteristic principal cluster. In the case when interatomic force constants (IFCs) inside the cluster lead to stronger interaction than the interaction between the clusters, a new rule for determining the characteristic principal cluster in the “cluster-plus-glue-atom” model has been proposed on the basis of IFCs. To verify this new rule, the alloy phases in Cu–Zr and Al–Ni–Zr systems have been tested, and our results indicate that the present new rule for determining characteristic principal clusters is effective and reliable

  6. Fibrinogen and thrombin concentrations are critical for fibrin glue adherence in rat high-risk colon anastomoses

    Directory of Open Access Journals (Sweden)

    Eliseo Portilla-de Buen

    2014-04-01

    Full Text Available OBJECTIVE: Fibrin glues have not been consistently successful in preventing the dehiscence of high-risk colonic anastomoses. Fibrinogen and thrombin concentrations in glues determine their ability to function as sealants, healers, and/or adhesives. The objective of the current study was to compare the effects of different concentrations of fibrinogen and thrombin on bursting pressure, leaks, dehiscence, and morphology of high-risk ischemic colonic anastomoses using fibrin glue in rats. METHODS: Colonic anastomoses in adult female Sprague-Dawley rats (weight, 250-350 g treated with fibrin glue containing different concentrations of fibrinogen and thrombin were evaluated at post-operative day 5. The interventions were low-risk (normal or high-risk (ischemic end-to-end colonic anastomoses using polypropylene sutures and topical application of fibrinogen at high (120 mg/mL or low (40 mg/mL concentrations and thrombin at high (1000 IU/mL or low (500 IU/mL concentrations. RESULTS: Ischemia alone, anastomosis alone, or both together reduced the bursting pressure. Glues containing a low fibrinogen concentration improved this parameter in all cases. High thrombin in combination with low fibrinogen also improved adherence exclusively in low-risk anastomoses. No differences were detected with respect to macroscopic parameters, histopathology, or hydroxyproline content at 5 days post-anastomosis. CONCLUSIONS: Fibrin glue with a low fibrinogen content normalizes the bursting pressure of high-risk ischemic left-colon anastomoses in rats at day 5 after surgery.

  7. Optimization of performance parameters for large area silicon photomultipliers for use in the GlueX experiment

    Science.gov (United States)

    Janzen, Kathryn Louise

    Largely because of their resistance to magnetic fields, silicon photomultipliers (SiPMs) are being considered as the readout for the GlueX Barrel Calorimeter, a key component of the GlueX detector located immediately inside a 2.2 T superconducting solenoid. SiPMs with active area 1 x 1 mm2 have been investigated for use in other experiments, but detectors with larger active areas are required for the GlueX BCAL. This puts the GlueX collaboration in the unique position of being pioneers in the use of this frontend detection revolution by driving the technology for larger area sensors. SensL, a photonics research and development company in Ireland, has been collaborating with the University of Regina GlueX group to develop prototype large area SiPMs comprising 16 - 3x3 mm2 cells assembled in a close-packed matrix. Performance parameters of individual SensL 1x1 mm2 and 3x3 mm2 SiPMs along with prototype SensL SiPM arrays are tested, including current versus voltage characteristics, photon detection efficiency, and gain uniformity, in an effort to determine the suitability of these detectors to the GlueX BCAL readout.

  8. Effect of fibrin glue on the biomechanical properties of human Descemet's membrane.

    Directory of Open Access Journals (Sweden)

    Shyam S Chaurasia

    Full Text Available BACKGROUND: Corneal transplantation has rapidly evolved from full-thickness penetrating keratoplasty (PK to selective tissue corneal transplantation, where only the diseased portions of the patient's corneal tissue are replaced with healthy donor tissue. Descemet's membrane endothelial keratoplasty (DMEK performed in patients with corneal endothelial dysfunction is one such example where only a single layer of endothelial cells with its basement membrane (10-15 µm in thickness, Descemet's membrane (DM is replaced. It is challenging to replace this membrane due to its intrinsic property to roll in an aqueous environment. The main objective of this study was to determine the effects of fibrin glue (FG on the biomechanical properties of DM using atomic force microscopy (AFM and relates these properties to membrane folding propensity. METHODOLOGY/PRINCIPAL FINDINGS: Fibrin glue was sprayed using the EasySpray applicator system, and the biomechanical properties of human DM were determined by AFM. We studied the changes in the "rolling up" tendency of DM by examining the changes in the elasticity and flexural rigidity after the application of FG. Surface topography was assessed using scanning electron microscopy (SEM and AFM imaging. Treatment with FG not only stabilized and stiffened DM but also led to a significant increase in hysteresis of the glue-treated membrane. In addition, flexural or bending rigidity values also increased in FG-treated membranes. CONCLUSIONS/SIGNIFICANCE: Our results suggest that fibrin glue provides rigidity to the DM/endothelial cell complex that may aid in subsequent manipulation by maintaining tissue integrity.

  9. Effect of Fibrin Glue on the Biomechanical Properties of Human Descemet's Membrane

    Science.gov (United States)

    Chaurasia, Shyam S.; Champakalakshmi, Ravi; Li, Ang; Poh, Rebekah; Tan, Xiao Wei; Lakshminarayanan, Rajamani; Lim, Chwee T.; Tan, Donald T.; Mehta, Jodhbir S.

    2012-01-01

    Background Corneal transplantation has rapidly evolved from full-thickness penetrating keratoplasty (PK) to selective tissue corneal transplantation, where only the diseased portions of the patient's corneal tissue are replaced with healthy donor tissue. Descemet's membrane endothelial keratoplasty (DMEK) performed in patients with corneal endothelial dysfunction is one such example where only a single layer of endothelial cells with its basement membrane (10–15 µm in thickness), Descemet's membrane (DM) is replaced. It is challenging to replace this membrane due to its intrinsic property to roll in an aqueous environment. The main objective of this study was to determine the effects of fibrin glue (FG) on the biomechanical properties of DM using atomic force microscopy (AFM) and relates these properties to membrane folding propensity. Methodology/Principal Findings Fibrin glue was sprayed using the EasySpray applicator system, and the biomechanical properties of human DM were determined by AFM. We studied the changes in the “rolling up” tendency of DM by examining the changes in the elasticity and flexural rigidity after the application of FG. Surface topography was assessed using scanning electron microscopy (SEM) and AFM imaging. Treatment with FG not only stabilized and stiffened DM but also led to a significant increase in hysteresis of the glue-treated membrane. In addition, flexural or bending rigidity values also increased in FG-treated membranes. Conclusions/Significance Our results suggest that fibrin glue provides rigidity to the DM/endothelial cell complex that may aid in subsequent manipulation by maintaining tissue integrity. PMID:22662156

  10. Comparison of mechanical compressive properties of commercial and autologous fibrin glues for tissue engineering applications.

    Science.gov (United States)

    Cravens, Matthew G; Behn, Anthony W; Dragoo, Jason L

    2017-11-01

    Fibrin glues are widely used in orthopedic surgery as adhesives and hemostatic agents. We evaluated the compressive properties of selected fibrin glues in order to identify which are appropriate for tissue regeneration applications subject to compression. Uniaxial unconfined compression tests were performed on fibrin gels prepared from commercial and autologous products: (1) Evicel (Ethicon), (2) Tisseel (Baxter), (3) Angel (Arthrex), and (4) ProPlaz (Biorich). Cyclic loads were applied from 0 to 30% strain for 100cycles at 0.5Hz. Following cyclic testing, specimens were subjected to ramp displacement of 1% strain per second to 80% strain. Throughout cyclic loading, Evicel and Tisseel deformed (shortened) less than Angel at all but one time point, and deformed less than ProPlaz at cycles 10 and 20. The dynamic moduli, peak stress, and strain energy were significantly greater in Tisseel than all other groups. Evicel displayed significantly greater dynamic moduli, peak stress, and strain energy than Angel and ProPlaz. Following cyclic testing, Tisseel and Evicel were significantly less deformed than Angel. No specimens exhibited gross failure during ramp loading to 80% strain. Ramp loading trends mirrored those of cyclic loading. The tested commercial glues were significantly more resistant to compression than the autologous products. The compressive properties of Tisseel were approximately twice those of Evicel. All preparations displayed moduli multiple orders of magnitude less than that of native articular cartilage. We conclude that in knee surgeries requiring fibrin glue to undergo compression of daily activity, commercial products are preferable to autologous preparations from platelet-poor plasma, though both will deform significantly. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Glue-sniffing as a cause of a positive radio-isotope brain scan

    Energy Technology Data Exchange (ETDEWEB)

    Lamont, C M; Adams, F G

    1982-08-01

    Convulsions are a known complication of the acute intoxicant effects of solvent abuse. A radio-isotope brain scan done 9 months following status epilepticus secondary to toluene inhalation, in a previously normal school-boy, demonstrated several wedge-shaped areas of increased uptake, in both cerebral hemispheres, consistent with infarcts. It is worth remembering that a positive brain scan in a young person, with recent onset of epilepsy, may be due to glue-sniffing.

  12. Glue-sniffing as a cause of a positive radio-isotope brain scan

    International Nuclear Information System (INIS)

    Lamont, C.M.; Adams, F.G.

    1982-01-01

    Convulsions are a known complication of the acute intoxicant effects of solvent abuse. A radio-isotope brain scan done 9 months following status epilepticus secondary to toluene inhalation, in a previously normal school-boy, demonstrated several wedge-shaped areas if increased uptake, in both cerebral hemispheres, consistent with infarcts. It is worth remembering that a positive brain scan in a young person, with recent onset of epilepsy, may be due to glue-sniffing. (orig.)

  13. [The influence of biological compatibility of the cyanoacrylate glue on regeneration of the cartilaginous tissue].

    Science.gov (United States)

    Semenov, F V; Skibitskaya, N F

    The objective of the present study was to evaluate the possibility of the application of the cyanoacrylate-based glue for the strengthening of the reconstructed elements of the middle ear and its influence on the regeneration of the cartilaginous tissue. We used the cartilaginous tissue from the auricles of the male California rabbits as a model. The cartilage was destroyed in a standard press. Half of the cartilage thus fragmented was implanted into the left auricle. The remaining part was mixed up with the cyanoacrylate glue and implanted into the right auricle of the same animal. The implanted material was used for the morphological study on day 10, within 1 and 2 months after the beginning of the experiment. The results of the study confirm the absence of the toxic action of the biologically compatible cyanoacrylate-based glue on the regeneration of the cartilaginous and connective tissues which suggests the possibility of its application for the surgical treatment of the diseases of the middle ear.

  14. Intraoperative use of fibrin glue dyed with methylene blue in surgery for branchial cleft anomalies.

    Science.gov (United States)

    Piccioni, Michela; Bottazzoli, Marco; Nassif, Nader; Stefini, Stefania; Nicolai, Piero

    2016-09-01

    We present a new method of optimizing the results of surgery for branchial cleft anomalies based on the intraoperative injection of fibrin glue combined with methylene blue dye. Retrospective single-center cohort study. The method was applied in 17 patients suffering from branchial anomalies. Six (35.29%) had a preauricular lesion; three (17.65%) had lesions derived from the first arch/pouch/groove (type I), four (23.53%) had lesions derived from the first (type II), one (5.88%) had lesions derived from the second, one (5.88%) had lesions derived from the third, and two (11.76%) had lesions derived from the fourth. The median and mean age at surgery were 10 and 10.6 years, respectively. All patients were followed by periodic clinical and ultrasonographic examination. The combination of fibrin glue with methylene blue facilitated the correct assessment of the extension of the lesions and their intraoperative manipulation. After a mean follow-up of 47.8 months, all patients were free of disease. Intraoperative injection of branchial fistulae and cysts by a mixture of fibrin glue and methylene blue is an effective, easy, and safe tool to track lesions and achieve radical resection. The technique requires a definitive validation on a large cohort with adequate stratification of patients. 4 Laryngoscope, 126:2147-2150, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  15. The impact and adoption of GLUE 2.0 in the LCG/EGEE production Grid

    International Nuclear Information System (INIS)

    Burke, Stephen; Andreozzi, Sergio; Donno, Flavia; Ehm, Felix; Field, Laurence; Litmaath, Maarten; Millar, Paul

    2010-01-01

    The GLUE information schema has been in use in the LCG/EGEE production Grid since the first version was defined in 2002. In 2007 a major redesign of GLUE, version 2.0, was started in the context of the Open Grid Forum following the creation of the GLUE Working Group. This process has taken input from a number of Grid projects, but as a major user of the version 1 schema LCG/EGEE has had a strong interest that the new schema should support its needs. In this paper we discuss the structure of the new schema in the light of the LCG/EGEE requirements and explain how they are met, and where improvements have been achieved compared with the version 1 schema. In particular we consider some difficulties encountered in recent extensions of the use of the version 1 schema to aid resource accounting in LCG, to enable the use of the SRM version 2 storage protocol by the LHC experiments, and to publish information about a wider range of services to improve service discovery. We describe how these can be better met by the new schema, and we also discuss the way in which the transition to the new schema is being managed.

  16. Use of fibrin glue in the management of recurrent pterygium by conjunctival autograft

    International Nuclear Information System (INIS)

    Virendra K. Malik; Sandeep Kumar

    2010-01-01

    To evaluate whether use of fibrin glue instead of sutures for the treatment of recurrent pterygium with conjunctival auto-graft (CAG) further decreases its recurrence. A prospective, clinical open trial of 50 eyes of 50 patients with recurrent pterygium, who were randomly assigned to either, pterygium excision and CAG with fibrin glue (Group 1) or with 6 interrupted sutures (Group 2), was carried out from January 2009 to July 2010 at the outpatient department of Subharti Medical College, Meerut, North India. Both groups had 25 patients each. The groups were compared with regards to the surgical time taken, development of recurrence, postoperative symptoms (irritation, watering, and redness), and complications. Recurrence was seen in one (4%) eye in group I, and 3 (12%) eyes in group II after 9-13 months of follow up. The difference between the 2 groups was not statistically significant. The surgical time was significantly reduced, and postoperative inflammation and complications were less in group I. Postoperative symptoms were significantly more in group II patients. While conjunctival autograft with sutures for management of recurrent pterygium appears to be a safe and feasible modality, fibrin glue fixation of the autograft is a more viable option in terms of surgical ease, less time consuming, less postoperative complications, and less recurrence (Author).

  17. Effect of Wheat Straw Pretreatments and Glue Formulations on particle board properties

    International Nuclear Information System (INIS)

    Jabeen, S.; Naveed, S.; Yousaf, S.; Ramzan, N.

    2014-01-01

    In this paper, the effect of wheat straw (WS) pretreatments and glue formulations on mechanical (i.e. Compressive Strength (CS) and Impact Strength (IS)) and water resistance properties (i.e. Thickness Swelling (TS) and water absorption (WA)) of particle board have been investigated and the results have been compared with conventional wooden particleboard. Wheat straw was treated with steam available at 110 degree C and 20 psig, for the retention time of 5, 10 and 15 min. The solution of 10% HCl was also used for removing the lignin. Particleboard was prepared by bonding treated WS with four types of glue recipes of synthetic and natural binders like urea formaldehyde (UF), polyvinyl acetate (PVA), corn flour (CF) and wheat flour (WF). The particle board was formed at the hydraulic pressure and temperature of 2800 psig and 80 degree C respectively. It was observed that WS particleboard has low mechanical strength and high water resistance in comparison with conventional board. The particle board prepared with HCl cured wheat straw and glue having high urea formaldehyde and corn flour has higher CS and IS as well as low TS and WA. It may be concluded that wheat straw is a good substitute of wood for particle board while using HCl as a modifying chemical and strong binders like urea formaldehyde and corn flour. (author)

  18. A direct biocombinatorial strategy toward next generation, mussel-glue inspired saltwater adhesives.

    Science.gov (United States)

    Wilke, Patrick; Helfricht, Nicolas; Mark, Andreas; Papastavrou, Georg; Faivre, Damien; Börner, Hans G

    2014-09-10

    Biological materials exhibit remarkable, purpose-adapted properties that provide a source of inspiration for designing new materials to meet the requirements of future applications. For instance, marine mussels are able to attach to a broad spectrum of hard surfaces under hostile conditions. Controlling wet-adhesion of synthetic macromolecules by analogue processes promises to strongly impact materials sciences by offering advanced coatings, adhesives, and glues. The de novo design of macromolecules to mimic complex aspects of mussel adhesion still constitutes a challenge. Phage display allows material scientists to design specifically interacting molecules with tailored affinity to material surfaces. Here, we report on the integration of enzymatic processing steps into phage display biopanning to expand the biocombinatorial procedure and enable the direct selection of enzymatically activable peptide adhesion domains. Adsorption isotherms and single molecule force spectroscopy show that those de novo peptides mimic complex aspects of bioadhesion, such as enzymatic activation (by tyrosinase), the switchability from weak to strong binders, and adsorption under hostile saltwater conditions. Furthermore, peptide-poly(ethylene oxide) conjugates are synthesized to generate protective coatings, which possess anti-fouling properties and suppress irreversible interactions with blood-plasma protein cocktails. The extended phage display procedure provides a generic way to non-natural peptide adhesion domains, which not only mimic nature but also improve biological sequence sections extractable from mussel-glue proteins. The de novo peptides manage to combine several tasks in a minimal 12-mer sequence and thus pave the way to overcome major challenges of technical wet glues.

  19. EFFICACY OF THROMBIN FIBRIN GLUE AND SCLE ROSANT IN THE MANAGEMENT OF BLEEDI NG GASTRIC VARICES

    Directory of Open Access Journals (Sweden)

    Sanjay Gupta

    2015-01-01

    Full Text Available Gastric varices are noted in up to 20 % of patents with portal hypertension , and are more common in those with non - cirrhotic etiology 1 . They bleed at lower portal pressures , bleed more severely and are associated with higher rates of rebleed , encephalopathy and mortality 1,2,3 . Variceal obliteration using tissue adhesives such as N - butyl cyanoacrylate leading to plugging and thrombosis of the gastric varices is currently the first line management option for obliteration of the gastric varices 3 . Although various options have been proposed , gold standard for management of gastric variceal bleeds is yet to be defined. We theorized that injection of the gastric varices using thrombin based glue followed by injection of a sclerosant shall be effective in optimum sclerotherapy and eradication of gastric varices. MATERIAL AND METHODS : All patients presenting with gastric variceal bleed were offered sclerotherapy with Thrombin fibrin based glue and sclerosant (TFG/S . During the study period 18 patients were enrolled in the TGF/S group. 21 patients underwent variceal plugging with n - butyl cyanoacrylate (NBC . There was no significant difference in age/ sex , duration of bleed or time interval between onset of bleed and endotherapy. RESULTS: Patients undergoing endotherapy with TGF/S had less episodes of bleed , and greater eradication of varices. CONCLUSION: The results with thrombin / fibrin glue and sclerotherapy are highly encouraging. Well - designed trials need to be performed KEYWORDS:Gastric varices; Thrombin Sclerotherapy

  20. Use of tissue glue for punch grafting in vitiligo - A preliminary report

    Directory of Open Access Journals (Sweden)

    Ghorpade Ashok

    2004-05-01

    Full Text Available BACKGROUND: Minipunch grafting has been successfully used for the treatment of stable vitiligo since several years. Post-operative immobilization at certain sites such as lips, areola & infralabial folds and joints is not easy to achieve. Putting stay sutures on the lips and areolae is difficult. Grafting over the joints may require hospitalization to ensure proper immobilization, and may discourage some patients. AIM: To study the efficacy of a tissue glue for immobilization of donor grafts at the above sites during minipunch grafting. METHODS: Ten cases with stable vitiligo over the lips, areolae, below the lower lip, and over different joints had tissue glue applied to the edges between the donor grafts and the recipient wells, after the grafting. RESULTS: The grafts adhered firmly within a minute and there was no need for a cumbersome dressing. Over the lips, the patients could resume talking and drinking fluids immediately. CONCLUSION: The glue was very helpful for immobilizing the grafts at these difficult sites.

  1. Generalized Likelihood Uncertainty Estimation (GLUE) Using Multi-Optimization Algorithm as Sampling Method

    Science.gov (United States)

    Wang, Z.

    2015-12-01

    For decades, distributed and lumped hydrological models have furthered our understanding of hydrological system. The development of hydrological simulation in large scale and high precision elaborated the spatial descriptions and hydrological behaviors. Meanwhile, the new trend is also followed by the increment of model complexity and number of parameters, which brings new challenges of uncertainty quantification. Generalized Likelihood Uncertainty Estimation (GLUE) has been widely used in uncertainty analysis for hydrological models referring to Monte Carlo method coupled with Bayesian estimation. However, the stochastic sampling method of prior parameters adopted by GLUE appears inefficient, especially in high dimensional parameter space. The heuristic optimization algorithms utilizing iterative evolution show better convergence speed and optimality-searching performance. In light of the features of heuristic optimization algorithms, this study adopted genetic algorithm, differential evolution, shuffled complex evolving algorithm to search the parameter space and obtain the parameter sets of large likelihoods. Based on the multi-algorithm sampling, hydrological model uncertainty analysis is conducted by the typical GLUE framework. To demonstrate the superiority of the new method, two hydrological models of different complexity are examined. The results shows the adaptive method tends to be efficient in sampling and effective in uncertainty analysis, providing an alternative path for uncertainty quantilization.

  2. Strenght of the glue line of edge glued panels of Pinus taeda made with different adhesives

    Directory of Open Access Journals (Sweden)

    Merielen de Carvalho Lopes

    2013-12-01

    Full Text Available The study compares the strength of the glue line of edge glued panels of Pinus taeda made with different industrial adhesives. Three types of adhesives (poly(vinyl acetate (PVAc, emulsion polymer isocyanate (EPI and polyurethane (PU glued in two side gluing orientation (radial and tangential and analyzed after the conditioning tests (dry and wet were analyzed. The 360 specimens were prepared for determining the shear strength of edge glued panels of Pinus taeda, and these were tested in a universal testing machine called EMIC. The shear strength of the glue line at dry condition was lower in the tangential side for the three types of adhesives analyzed. The PU adhesive showed the highest values of shear strength in the applied conditions, differing from PVAc and EPI adhesive when tested on dry condition and did not differ from the others adhesives when tested on wet condition. The highest percentage of wood failure was observed after the shear strength test at dry condition to EPI adhesive glued in the radial side. And in the wet condition, the EPI adhesive and PU adhesive glued in tangential side showed higher mean values of wood failure. Thus, it was possible to conclude that the strength of the glue line of Pinus taeda wood was influenced by the type of adhesive and side gluing orientation, and showed differently behavior according to the condition of use (wet or dry.

  3. Percutaneous Glue Embolization of a Visceral Artery Pseudoaneurysm in a Case of Sickle Cell Anemia

    International Nuclear Information System (INIS)

    Gulati, Gurpreet S.; Gulati, Manpreet S.; Makharia, Govind; Hatimota, Pradeep; Saikia, Nripen; Paul, Shashi B.; Acharya, Subrat

    2006-01-01

    Although aneurysmal complications of sickle cell anemia have been described in the intracranial circulation, visceral artery pseudoaneurysms in this disease entity have not previously been reported in the literature. Conventional treatment of visceral pseudoaneurysms has been surgical ligation or resection of the aneurysm. Transcatheter embolization has emerged as an attractive, minimally invasive alternative to surgery in the treatment of these lesions. In certain situations, however, due to the unfavorable angiographic anatomy precluding safe transcatheter embolization, direct percutaneous glue injection of the pseudoaneurysm sac may be considered to achieve successful occlusion of the sac. The procedure may be rendered safer by simultaneous balloon protection of the parent artery. We describe this novel treatment modality in a case of inferior pancreaticoduodenal artery pseudoaneurysm in a patient with sickle cell anemia. Although a complication in the form of glue reflux into the parent vessel occurred that necessitated surgery, this treatment modality may be used in very selected cases (where conventional endovascular embolization techniques are not applicable) after careful selection of the balloon diameter and appropriate concentration of the glue-lipiodol mixture

  4. [Propolis. The bee glue as presented by the Graeco-Roman literature].

    Science.gov (United States)

    Golder, Werner

    2004-01-01

    The bee glue, commonly known as propolis, has been employed for medical purposes already in teh ancient world. More than 15 Greek and Roman authors report on the preparation and application of the so-called third natural product of the bees (besides honey and wax). Aristoteles described the fundamental issues of its biology in his 'Historia Animalium' correctly. The bulk of propolis is obtained from the barks of poplars. Once carried in the hives, the glue is used to stabilize the cells and honeycombs and to protect the bees against invaders and cold weather. Propolis has been chiefly employed for the preparation of ointment and plasters. For this purpose, the viscous raw material was purified, moulded and boiled. In most preparations, the bee glue was only one of many (up to 20) pharmacologically active constituents and came to five to 20% of the mixture. Only rarely, a single drug therapy was using propolis was carried out. The application of the glue was most successful in general surgery and casualties. In that respect, the ancient physicians took advantage of the anti-edematous and anti-infectious properties of the substance. Thus, it was used to treat bumps, indurations, and slow-healing wounds. Moreover, cataplasms against swollen cervical nodes and indurations of the female breast often contained propolis. Finally, bee glue proved successful for the treatment of chronic backache and pain in the hip as well as fresh injuries of muscles and tendons. In the sector of skin diseases, lichens and condylomata were found to respond well to propolis. ALl this indications have been a matter of several records. However, the successful use of propolis in diseases of the stomach and liver has ben reported solely by Alexander of Tralles (6th century AD). Not counting the internal diseases, the spectrum of indications for propolis has not substantially changed as compared to the classical antiquity. Interestingly, radiation therapists have adopted the ancient remedy and

  5. Mesh fixation with glue versus suture for chronic pain and recurrence in Lichtenstein inguinal hernioplasty.

    Science.gov (United States)

    Sun, Ping; Cheng, Xiang; Deng, Shichang; Hu, Qinggang; Sun, Yi; Zheng, Qichang

    2017-02-07

    Chronic pain following mesh-based inguinal hernia repair is frequently reported, and has a significant impact on quality of life. Whether mesh fixation with glue can reduce chronic pain without increasing the recurrence rate is still controversial. To determine whether tissue adhesives can reduce postoperative complications, especially chronic pain, with no increase in recurrence rate, compared with sutures for mesh fixation in Lichtenstein hernia repair. We searched the following electronic databases with no language restrictions: the Cochrane Central Register of Controlled Trials (CENTRAL; issue 4, 2016) in the Cochrane Library (searched 11 May 2016), MEDLINE Ovid (1986 to 11 May 2016), Embase Ovid (1986 to 11 May 2016), Science Citation Index (Web of Science) (1986 to 11 May 2016), CBM (Chinese Biomedical Database), CNKI (China National Knowledge Infrastructure), VIP (a full-text database in China), Wanfang databases. We also checked reference lists of identified papers (included studies and relevant reviews). We included all randomised and quasi-randomised controlled trials comparing glue versus sutures for mesh fixation in Lichtenstein hernia repair. Cluster-RCTs were also eligible. Two review authors extracted data and assessed the risk of bias independently. Dichotomous outcomes were expressed as odds ratio (OR) with 95% confidence intervals (CI). Continuous outcomes were expressed as mean differences (MD) with 95% CIs. Twelve trials with a total of 1932 participants were included in this review. The overall postoperative chronic pain in the glue group was reduced by 37% (OR 0.63, 95% CI 0.44 to 0.91; 10 studies, 1418 participants, low-quality evidence) compared with the suture group. However, the results changed when we conducted subgroup analysis with regard to the type of mesh. Subgroup analysis of included studies using lightweight mesh showed the reduction of chronic pain was less profound and insignificant (OR 0.77, 95% CI 0.50 to 1.17). Subgroup

  6. Alternative glues for the production of ATLAS silicon strip modules for the Phase-II upgrade of the ATLAS Inner Detector

    Science.gov (United States)

    Poley, L.; Bloch, I.; Edwards, S.; Friedrich, C.; Gregor, I.-M.; Jones, T.; Lacker, H.; Pyatt, S.; Rehnisch, L.; Sperlich, D.; Wilson, J.

    2016-05-01

    The Phase-II upgrade of the ATLAS detector for the High Luminosity Large Hadron Collider (HL-LHC) includes the replacement of the current Inner Detector with an all-silicon tracker consisting of pixel and strip detectors. The current Phase-II detector layout requires the construction of 20,000 strip detector modules consisting of sensor, circuit boards and readout chips, which are connected mechanically using adhesives. The adhesive used initially between readout chips and circuit board is a silver epoxy glue as was used in the current ATLAS SemiConductor Tracker (SCT). However, this glue has several disadvantages, which motivated the search for an alternative. This paper presents a study of six ultra-violet (UV) cure glues and a glue pad for possible use in the assembly of silicon strip detector modules for the ATLAS upgrade. Trials were carried out to determine the ease of use, thermal conduction and shear strength. Samples were thermally cycled, radiation hardness and corrosion resistance were also determined. These investigations led to the exclusion of three UV cure glues as well as the glue pad. Three UV cure glues were found to be possible better alternatives than silver loaded glue. Results from electrical tests of first prototype modules constructed using these glues are presented.

  7. Alternative glues for the production of ATLAS silicon strip modules for the Phase-II upgrade of the ATLAS Inner Detector

    International Nuclear Information System (INIS)

    Poley, L.; Bloch, I.; Friedrich, C.; Gregor, I.-M.; Edwards, S.; Pyatt, S.; Wilson, J.; Jones, T.; Lacker, H.; Rehnisch, L.; Sperlich, D.

    2016-01-01

    The Phase-II upgrade of the ATLAS detector for the High Luminosity Large Hadron Collider (HL-LHC) includes the replacement of the current Inner Detector with an all-silicon tracker consisting of pixel and strip detectors. The current Phase-II detector layout requires the construction of 20,000 strip detector modules consisting of sensor, circuit boards and readout chips, which are connected mechanically using adhesives. The adhesive used initially between readout chips and circuit board is a silver epoxy glue as was used in the current ATLAS SemiConductor Tracker (SCT). However, this glue has several disadvantages, which motivated the search for an alternative. This paper presents a study of six ultra-violet (UV) cure glues and a glue pad for possible use in the assembly of silicon strip detector modules for the ATLAS upgrade. Trials were carried out to determine the ease of use, thermal conduction and shear strength. Samples were thermally cycled, radiation hardness and corrosion resistance were also determined. These investigations led to the exclusion of three UV cure glues as well as the glue pad. Three UV cure glues were found to be possible better alternatives than silver loaded glue. Results from electrical tests of first prototype modules constructed using these glues are presented.

  8. A comparative study of tissue glue and vicryl suture for conjunctival and scleral closure in conventional 20-gauge vitrectomy.

    Science.gov (United States)

    Batman, C; Ozdamar, Y; Mutevelli, S; Sonmez, K; Zilelioglu, G; Karakaya, J

    2009-06-01

    To describe the use of tissue glue to close scleral and conjunctival wounds, and to compare the clinical outcomes using tissue glue and vicryl suture for closing these areas in conventional 20-gauge (G) vitrectomy. Thirty eyes of 30 patients were included in this study. The indications for vitreoretinal surgery were diabetic vitreous haemorrhage with severe vitreoretinal traction in 10 eyes, retinal detachment and proliferative vitreoretinopathy in 14 eyes, and vitreous opacity in 6 eyes. Tissue glue (Tisseel, Baxter AG Industries, Vienna, Austria) was used to attach scleral and conjunctival wounds in 15 eyes and vicryl sutures in 15 eyes. The patients were allotted into two subgroups as tissue glue group (TG) and vicryl suture group (VG). The sclerotomy sites were evaluated with ultrasound biomicroscopy (UBM) postoperatively in TG. Follow-up period was 2 months. The groups were statistically compared for ocular signs and symptoms by Mann-Whitney U-test. No scleral wound leakage and conjunctival reattachment were observed at the end of the surgical procedure and during the follow-up period. No adverse effects were seen in TG. Abnormal fibrous ingrowth was not detected at the sclerotomy sites by means of UBM in TG. Patient comfort was significantly higher in TG than VG (P<0.05). Tissue glue has no adverse effects on ocular tissue and can be used as a substitute for suture materials, and the use of tissue glue decreases patient symptoms during the postoperative period after 20-G vitrectomy. Tissue glue can enable to perform sutureless surgery in the conventional 20-G vitrectomy.

  9. Biomechanical and histologic evaluation of two application forms of surgical glue for mesh fixation to the abdominal wall.

    Science.gov (United States)

    Ortillés, Á; Pascual, G; Peña, E; Rodríguez, M; Pérez-Köhler, B; Mesa-Ciller, C; Calvo, B; Bellón, J M

    2017-11-01

    The use of an adhesive for mesh fixation in hernia repair reduces chronic pain and minimizes tissue damage in the patient. This study was designed to assess the adhesive properties of a medium-chain (n-butyl) cyanoacrylate glue applied as drops or as a spray in a biomechanical and histologic study. Both forms of glue application were compared to the use of simple-loose or continuous-running polypropylene sutures for mesh fixation. Eighteen adult New Zealand White rabbits were used. For mechanical tests in an ex vivo and in vivo study, patches of polypropylene mesh were fixed to an excised fragment of healthy abdominal tissue or used to repair a partial abdominal wall defect in the rabbit respectively. Depending on the fixation method used, four groups of 12 implants each or 10 implants each respectively for the ex vivo and in vivo studies were established: Glue-Drops, Glue-Spray, Suture-Simple and Suture-Continuous. Biomechanical resistance in the ex vivo implants was tested five minutes after mesh fixation. In vivo implants for biomechanical and histologic assessment were collected at 14 days postimplant. In the ex vivo study, the continuous suture implants showed the highest failure sample tension, while the implants fixed with glue showed lower failure sample tension values. However, the simple and continuous suture implants returned the highest stretch values. In the in vivo implants, failure sample tension values were similar among groups while the implants fixed with a continuous running suture had the higher stretch values, and the glue-fixed implants the lower stretch values. All meshes showed good tissue integration within the host tissue regardless of the fixation method used. Our histologic study revealed the generation of a denser, more mature repair tissue when the cyanoacrylate glue was applied as a spray rather than as drops. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Fibrin glue mixed with platelet-rich fibrin as a scaffold seeded with dental bud cells for tooth regeneration.

    Science.gov (United States)

    Yang, Kai-Chiang; Wang, Chun-Hao; Chang, Hao-Hueng; Chan, Wing P; Chi, Chau-Hwa; Kuo, Tzong-Fu

    2012-11-01

    Odontogenesis is a complex process with a series of epithelial-mesenchymal interactions and odontogenic molecular cascades. In tissue engineering of teeth from stem cells, platelet-rich fibrin (PRF), which is rich in growth factors and cytokines, may improve regeneration. Accordingly, PRF was added into fibrin glue to enrich the microenvironment with growth factors. Unerupted second molar tooth buds were harvested from miniature swine and cultured in vitro for 3 weeks to obtain dental bud cells (DBCs). Whole blood was collected for the preparation of PRF and fibrin glue before surgery. DBCs were suspended in fibrin glue and then enclosed with PRF, and the DBC-fibrin glue-PRF composite was autografted back into the original alveolar sockets. Radiographic and histological examinations were used to identify the regenerated tooth structure 36 weeks after implantation. Immunohistochemical staining was used to detect proteins specific to tooth regeneration. One pig developed a complete tooth with crown, root, pulp, enamel, dentin, odontoblast, cementum, blood vessels, and periodontal ligaments in indiscriminate shape. Another animal had an unerupted tooth that expressed cytokeratin 14, dentin matrix protein-1, vascular endothelial growth factor, and osteopontin. This study demonstrated, using autogenic cell transplantation in a porcine model, that DBCs seeded into fibrin glue-PRF could regenerate a complete tooth. Copyright © 2011 John Wiley & Sons, Ltd.

  11. Introduction of a potent single-donor fibrin glue for vascular anastomosis: An animal study

    Directory of Open Access Journals (Sweden)

    Mehdi Rasti Ardakani

    2012-01-01

    Full Text Available Background: Vascular anastomosis is considered as a difficult surgical procedure. Although different alternative methods have been tried to tackle these difficulties, none were found to be successful. Commercial fibrin glue has recently been used for vascular anastomosis. However, it did not gain popularity due to some limitations such as low tensile strength, rapid removal by the immune system, and risk of transmission of blood-borne viral infections. In this article, we presented a novel method for producing single-donor human fibrin glue and determined its success rate for vascular anastomosis in an animal model. Materials ans Methods : In this study, 3 mL of single-donor fibrin sealant was prepared from 150 mL of whole blood containing 50-70 mg/mL of fibrinogen. The study was performed on 10 dogs and 5 cats. After transection of the carotid artery, both ends were anastomosed by means of 3-4 sutures (Prolene 8-0. The suture line was then sealed with one layer of the new fibrin sealant. After 3-8 weeks, the site of anastomosis was evaluated angiographically and morphologically for healing and possible complications such as thrombosis or aneurysm. Results: In evaluations 3 weeks after the surgery, all arterial anastomoses were patent in dogs, but some degree of subintimal hyperplasia was noted. After 8 weeks, all anastomoses were patent and the degree of subintimal hyperplasia was decreased. In cats on the other hand, after 4 weeks, all anastomoses were patent and subintimal hyperplasia was absent. Conclusions: Single-donor fibrin glue was a quite reliable and practical alternative to minimize suturing and therefore operative time in our animal model. This sealant can easily be obtained from the patient′s whole blood. Its application in humans would require further studies.

  12. Application of fibrin glue with bandage contact lens in pterygium surgery

    Directory of Open Access Journals (Sweden)

    Wei Liu

    2014-05-01

    Full Text Available AIM: To explore the efficacy of fibrin glue with bandage contact lens for pain relief after pterygium surgery performed with limbal autograft transplantation.METHODS: A prospective clinical trial was carried out in 52 patients(72 eyesoperated for primary nasal pterygium. All patients were randomly divided into the fibrin glue with bandage contact lens group(experimental group, 28 cases, 38 eyesand suture group(control group, 24 cases, 34 eyes. Autologous limbal graft taken from the superotemporal limbus was used to cover the sclera after pterygium excision under local anesthesia with 20g/L lidocaine. In experimental group, the transplant was attached to the sclera with fibrin tissue adhesive and in control group with 10-0 Virgin silk sutures. Experimental group weared bandage contact lens after surgery while the control group did not. The degree of pain after surgery was evaluated at 1, 2, 3, 5 and 7d after surgery. Follow-up was 6mo, matching degree of graft and complication such as infection, relapse, implant healing badness and subconjunctival cyst were mainly observed and recorded.RESULTS: The pain index scores of the experimental group were significantly less than those of control group(all P=0.000. In observation period, all conjunctival autografts in both groups were successfully attached and were intact without falling off, dissolution or recurrence and there were no complications such as infection, relapse, implant healing badness and subconjunctival cyst.CONCLUSION: Fibrin glue with bandage contact lens could significantly release pain response afterpterygium excision surgery.

  13. In vitro study of a new biodegradable nanocomposite based on poly propylene fumarate as bone glue

    Energy Technology Data Exchange (ETDEWEB)

    Shahbazi, S.; Moztarzadeh, F. [Department of Medical Engineering, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of); Sadeghi, G. Mir Mohamad [Department of Polymer Engineering and Color Technology, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of); Jafari, Y., E-mail: y.j.arisman@gmail.com [Department of Analytical Chemistry, Faculty of Chemistry, University of Kashan, Kashan (Iran, Islamic Republic of)

    2016-12-01

    A novel poly propylene fumarate (PPF)-based glue which is reinforced by nanobioactive glass (NBG) particles and promoted by hydroxyethyl methacrylate (HEMA) as crosslinker agent, was developed and investigated for bone-to-bone bonding applications. In-vitro bioactivity, biodegradability, biocompatibility, and bone adhesion were tested and the results have verified that it can be used as bone glue. In an in-vitro condition, the prepared nanocomposite (PPF/HEMA/NBG) showed improved adhesion to wet bone surfaces. The combined tension and shear resistance between two wet bone surfaces was measured, and its maximum value was 9 ± 59 MPa. To investigate the bioactivity and biodegradability of the nanocomposite, it has been immersed in simulated body fluid (SBF). After 14 days exposure to SBF, a hydroxyapatite (HA) layer formed on the surface of the composite confirms the bioactivity of this material. In the XRD pattern of the nanocomposite surface, the HA characteristic diffraction peak at θ = 26 and 31.8 were observed. Also, by monitoring the weight change after 8 weeks immersion in SBF, the mass loss was about 16.46 wt%. It has been confirmed that this nanocomposite is a biodegradable material. Also, bioactivity and biodegradability of nanocomposite have been proved by SEM images. It has been showed that by using NBG particles and HEMA precursor, mechanical properties increased significantly. The ultimate tensile strength (UTS) of nanocomposite which contains 20% NBG and the ratio of 70/30 wt% PPF/HEMA (PHB.732) was approximately 62 MPa, while the UTS in the pure PPF/HEMA was about 32 MPa. High cell viability in this nanocomposite (MTT assays, 85–95%) can be attributed to the NBG nature which contains calcium phosphate and is similar to physiological environment. Furthermore, it possesses biomineralization and biodegradation which significantly affected by impregnation of hydrophilic HEMA in the PPF-based polymeric matrix. The results indicated that the new

  14. TRANS-ARTERIAL EMBOLIZATION WITH N-BUTYL CYANOACRYLATE GLUE FOR RENAL BLEEDING: Case Report

    Directory of Open Access Journals (Sweden)

    Benny Young

    2014-08-01

    Full Text Available Background: The objectivity in management of renal bleeding is to preserve a significant renal parenchyma tissue and prevent associated morbidities like anemic shock or renal impairment from substantial nephron demise or obstructed uropathy. Trans-arterial embolization therapy by interventional radiology offers a high success rate with potential of reserving normal renal tissue. The selection material for renal arterial embolization largely depends on vasculature anatomy and end-point of procedure. N-butyl cyanoacrylate glue in our experience is applied in lesion supplied by small size of end-artery. 

  15. Elaboración de cola de pergamino = Preparation of parchment glue

    OpenAIRE

    Tacón Clavaín, Javier

    2013-01-01

    En las páginas siguientes se describe mediante imágenes el proceso llevado a cabo en el Departamento de Conservación y Restauración para la elaboración de cola de pergamino. Este adhesivo tradicional es muy adecuado para su uso en consolidaciones y adhesiones en el campo de la restauración documental por su pureza y por su pH neutro. [ABSTRACT]In the following pages the process carried out in the Department of Conservation and Restoration for making parchment glue is described. This tradit...

  16. Uncertainty and sensitivity assessments of an agricultural-hydrological model (RZWQM2) using the GLUE method

    Science.gov (United States)

    Sun, Mei; Zhang, Xiaolin; Huo, Zailin; Feng, Shaoyuan; Huang, Guanhua; Mao, Xiaomin

    2016-03-01

    Quantitatively ascertaining and analyzing the effects of model uncertainty on model reliability is a focal point for agricultural-hydrological models due to more uncertainties of inputs and processes. In this study, the generalized likelihood uncertainty estimation (GLUE) method with Latin hypercube sampling (LHS) was used to evaluate the uncertainty of the RZWQM-DSSAT (RZWQM2) model outputs responses and the sensitivity of 25 parameters related to soil properties, nutrient transport and crop genetics. To avoid the one-sided risk of model prediction caused by using a single calibration criterion, the combined likelihood (CL) function integrated information concerning water, nitrogen, and crop production was introduced in GLUE analysis for the predictions of the following four model output responses: the total amount of water content (T-SWC) and the nitrate nitrogen (T-NIT) within the 1-m soil profile, the seed yields of waxy maize (Y-Maize) and winter wheat (Y-Wheat). In the process of evaluating RZWQM2, measurements and meteorological data were obtained from a field experiment that involved a winter wheat and waxy maize crop rotation system conducted from 2003 to 2004 in southern Beijing. The calibration and validation results indicated that RZWQM2 model can be used to simulate the crop growth and water-nitrogen migration and transformation in wheat-maize crop rotation planting system. The results of uncertainty analysis using of GLUE method showed T-NIT was sensitive to parameters relative to nitrification coefficient, maize growth characteristics on seedling period, wheat vernalization period, and wheat photoperiod. Parameters on soil saturated hydraulic conductivity, nitrogen nitrification and denitrification, and urea hydrolysis played an important role in crop yield component. The prediction errors for RZWQM2 outputs with CL function were relatively lower and uniform compared with other likelihood functions composed of individual calibration criterion. This

  17. Lifetime Improvement of Organic Light Emitting Diodes using LiF Thin Film and UV Glue Encapsulation

    Science.gov (United States)

    Huang, Jian-Ji; Su, Yan-Kuin; Chang, Ming-Hua; Hsieh, Tsung-Eong; Huang, Bohr-Ran; Wang, Shun-Hsi; Chen, Wen-Ray; Tsai, Yu-Sheng; Hsieh, Huai-En; Liu, Mark O.; Juang, Fuh-Shyang

    2008-07-01

    This work demonstrates the use of lithium fluoride (LiF) as a passivation layer and a newly developed UV glue for encapsulation on the LiF passivation layer to enhance the stability of organic light-emitting devices (OLEDs). Devices with double protective layers showed a 25-fold increase in operational lifetime compared to those without any packaging layers. LiF has a low melting point and insulating characteristics and it can be adapted as both a protective layer and pre-encapsulation film. The newly developed UV glue has a fast curing time of only 6 s and can be directly spin-coated onto the surface of the LiF passivation layer. The LiF thin film plus spin-coated UV glue is a simple packaging method that reduces the fabrication costs of OLEDs.

  18. Alternative glues for the production of ATLAS silicon strip modules for the Phase-II upgrade of the ATLAS inner detector

    International Nuclear Information System (INIS)

    Poley, Luise; Bloch, Ingo; Edwards, Sam

    2016-04-01

    The Phase-II upgrade of the ATLAS detector for the High Luminosity Large Hadron Collider (HL-LHC) includes the replacement of the current Inner Detector with an all-silicon tracker consisting of pixel and strip detectors. The current Phase-II detector layout requires the construction of 20,000 strip detector modules consisting of sensor, circuit boards and readout chips, which are connected mechanically using adhesives. The adhesive between readout chips and circuit board is a silver epoxy glue as was used in the current ATLAS SemiConductor Tracker (SCT). This glue has several disadvantages, which motivated the search for an alternative. This paper presents a study concerning the use of six ultra-violet (UV) cure glues and a glue pad for use in the assembly of silicon strip detector modules for the ATLAS upgrade. Trials were carried out to determine the ease of use, the thermal conduction and shear strength, thermal cycling, radiation hardness, corrosion resistance and shear strength tests. These investigations led to the exclusion of three UV cure glues as well as the glue pad. Three UV cure glues were found to be possible better alternatives. Results from electrical tests of first prototype modules constructed using these glues are presented.

  19. Alternative glues for the production of ATLAS silicon strip modules for the Phase-II upgrade of the ATLAS inner detector

    Energy Technology Data Exchange (ETDEWEB)

    Poley, Luise [DESY, Zeuthen (Germany); Humboldt Univ. Berlin (Germany); Bloch, Ingo [DESY, Zeuthen (Germany); Edwards, Sam [Birmingham Univ. (United Kingdom); and others

    2016-04-15

    The Phase-II upgrade of the ATLAS detector for the High Luminosity Large Hadron Collider (HL-LHC) includes the replacement of the current Inner Detector with an all-silicon tracker consisting of pixel and strip detectors. The current Phase-II detector layout requires the construction of 20,000 strip detector modules consisting of sensor, circuit boards and readout chips, which are connected mechanically using adhesives. The adhesive between readout chips and circuit board is a silver epoxy glue as was used in the current ATLAS SemiConductor Tracker (SCT). This glue has several disadvantages, which motivated the search for an alternative. This paper presents a study concerning the use of six ultra-violet (UV) cure glues and a glue pad for use in the assembly of silicon strip detector modules for the ATLAS upgrade. Trials were carried out to determine the ease of use, the thermal conduction and shear strength, thermal cycling, radiation hardness, corrosion resistance and shear strength tests. These investigations led to the exclusion of three UV cure glues as well as the glue pad. Three UV cure glues were found to be possible better alternatives. Results from electrical tests of first prototype modules constructed using these glues are presented.

  20. Clinical evaluations of complete autologous fibrin glue, produced by the CryoSeal® FS system, and polyglycolic acid sheets as wound coverings after oral surgery.

    Science.gov (United States)

    Kouketsu, Atsumu; Nogami, Shinnosuke; Yamada-Fujiwara, Minami; Nagai, Hirokazu; Yamauchi, Kensuke; Mori, Shiro; Miyashita, Hitoshi; Kawai, Tadashi; Matsui, Aritsune; Kataoka, Yoshihiro; Satomi, Norihisa; Ezoe, Yushi; Abe, Satoko; Takeda, Yuri; Tone, Takeshi; Hirayama, Bunnichi; Kurobane, Tsuyoshi; Tashiro, Kazuki; Yanagisawa, Yuta; Takahashi, Tetsu

    2017-09-01

    The CryoSeal ® FS System has been recently introduced as an automated device for the production of complete fibrin glue from autologous plasma, rather than from pool allogenic or cattle blood, to prevent viral infection and allergic reaction. We evaluated the effectiveness of complete autologous fibrin glue and polyglycolic acid (PGA) sheet wound coverings in mucosa defect oral surgery. Postoperative pain, scar contracture, ingestion, tongue dyskinesia, and postoperative bleeding were evaluated in 12 patients who underwent oral (including the tongue) mucosa excision, and received a PGA sheet and an autologous fibrin glue covering. They were compared with 12 patients who received a PGA sheet and commercial allogenic fibrin glue. All cases in the complete autologous fibrin glue group demonstrated good wound healing without complications such as local infection or incomplete cure. All evaluated clinical measures in this group were similar or superior to the commercial allogenic fibrin glue group. Coagulation and adhesion quality achieved with this method was comparable to that with a PGA sheet and commercial fibrin glue. Covering oral surgery wounds with complete autologous fibrin glue produced by an automated device was convenient, safe, and reduced the risk of viral infection and allergic reaction associated with conventional techniques. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  1. A general contact mechanical formulation of multilayered structures and its application to deconvolute thickness/mechanical properties of glue used in surface force apparatus.

    Science.gov (United States)

    Math, Souvik; Horn, Roger; Jayaram, Vikram; Biswas, Sanjay Kumar

    2007-04-15

    Currently data obtained from surface force apparatus experiments are convoluted with the mechanical response of glue of unknown thickness, used to bond mica sheets to the substrates. This paper describes a formulation to precisely deconvolute out the forces between the mica sheets by determining the thickness of glue, knowing the mechanical properties of the glue. The formulation consists of a general solution based on the noniterative Hankel transform of the Laplace equation. The generality is achieved by treating all the layers except the one in contact as an effective lumped system consisting of a set of springs in series, where each spring represents a layer. The solution is validated by nanoindentation of trilayer systems consisting of layers with widely diverse mechanical properties, some differing from each other by three orders of magnitude. SFA experiments are done with carefully metered slabs of glue. The proposed method is validated by comparing the actual glue thicknesses with those determined using the present analysis.

  2. Glue ear: how good is the information on the World Wide Web?

    Science.gov (United States)

    Ritchie, L; Tornari, C; Patel, P M; Lakhani, R

    2016-02-01

    This paper objectively evaluates current information available to the general public related to glue ear on the World Wide Web. The term 'glue ear' was typed into the 3 most frequently used internet search engines - Google, Bing and Yahoo - and the first 20 links were analysed. The first 400 words of each page were used to calculate the Flesch-Kincaid readability score. Each website was subsequently graded using the Discern instrument, which gauges quality and content of literature. The websites Webmd.boots.com, Bupa.co.uk and Patient.co.uk received the highest overall scores. These reflected top scores in either readability or Discern instrument assessment, but not both. Readability and Discern scores increased with the presence of a marketing or advertising incentive. The Patient.co.uk website had the highest Discern score and third highest readability score. There is huge variation in the quality of information available to patients on the internet. Some websites may be accessible to a wide range of reading ages but have poor quality content, and vice versa. Clinicians should be aware of indicators of quality, and use validated instruments to assess and recommend literature.

  3. N-butyl Cyanoacrylate Glue Embolization of Arterial Networks to Facilitate Hepatic Arterial Skeletonization before Radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Samuelson, Shaun D.; Louie, John D.; Sze, Daniel Y., E-mail: dansze@stanford.edu [Stanford University School of Medicine, Division of Interventional Radiology (United States)

    2013-06-15

    Purpose. Avoidance of nontarget microsphere deposition via hepatoenteric anastomoses is essential to the safety of yttrium-90 radioembolization (RE). The hepatic hilar arterial network may remain partially patent after coil embolization of major arteries, resulting in persistent risk. We retrospectively reviewed cases where n-butyl cyanoacrylate (n-BCA) glue embolization was used to facilitate endovascular hepatic arterial skeletonization before RE. Methods. A total of 543 RE procedures performed between June 2004 and March 2012 were reviewed, and 10 were identified where n-BCA was used to embolize hepatoenteric anastomoses. Arterial anatomy, prior coil embolization, and technical details were recorded. Outcomes were reviewed to identify subsequent complications of n-BCA embolization or nontarget RE. Results. The rate of complete technical success was 80 % and partial success 20 %, with one nontarget embolization complication resulting in a minor change in treatment plan. No evidence of gastrointestinal or biliary ischemia or infarction was identified, and no microsphere-related gastroduodenal ulcerations or other evidence of nontarget RE were seen. Median volume of n-BCA used was <0.1 ml. Conclusion. n-BCA glue embolization is useful to eliminate hepatoenteric networks that may result in nontarget RE, especially in those that persist after coil embolization of major vessels such as the gastroduodenal and right gastric arteries.

  4. Management of nontraumatic corneal perforation with tectonic drape patch and cyanoacrylate glue.

    Science.gov (United States)

    Khalifa, Yousuf M; Bailony, M Rami; Bloomer, Michele M; Killingsworth, Daniel; Jeng, Bennie H

    2010-10-01

    To report a case of nontraumatic corneal perforation managed with a tectonic drape patch. Interventional case report. A 60-year-old patient with a corneal scar in his left eye likely secondary to herpes simplex virus interstitial keratitis underwent laser peripheral iridotomy for narrow angles. He developed progressive thinning of the cornea overlying the scar that led to a descemetocele and then ultimately a 1.2- × 1.7-mm perforation. Intraoperatively, several attempts were made to seal the perforation with cyanoacrylate glue, but the wound continued to leak. Sterile plastic drape that was on the surgical field was fashioned into a 2-mm-diameter patch, and the peripheral edge of the tectonic drape patch was glued over the perforation, successfully sealing the cornea. One week later, the drape patch was intact without leak, and a penetrating keratoplasty was carried out without complication. Tectonic drape patch technique for nontraumatic corneal perforations in which there is tissue loss is a viable temporizing option when cyanoacrylate glue alone fails and when there is no corneal tissue or amniotic membrane available to close the wound.

  5. Inorganic Glue Enabling High Performance of Silicon Particles as Lithium Ion Battery Anode

    KAUST Repository

    Cui, Li-Feng

    2011-01-01

    Silicon, as an alloy-type anode material, has recently attracted lots of attention because of its highest known Li+ storage capacity (4200 mAh/g). But lithium insertion into and extraction from silicon are accompanied by a huge volume change, up to 300, which induces a strong strain on silicon and causes pulverization and rapid capacity fading due to the loss of the electrical contact between part of silicon and current collector. Silicon nanostructures such as nanowires and nanotubes can overcome the pulverization problem, however these nano-engineered silicon anodes usually involve very expensive processes and have difficulty being applied in commercial lithium ion batteries. In this study, we report a novel method using amorphous silicon as inorganic glue replacing conventional polymer binder. This inorganic glue method can solve the loss of contact issue in conventional silicon particle anode and enables successful cycling of various sizes of silicon particles, both nano-particles and micron particles. With a limited capacity of 800 mAh/g, relatively large silicon micron-particles can be stably cycled over 200 cycles. The very cheap production of these silicon particle anodes makes our method promising and competitive in lithium ion battery industry. © 2011 The Electrochemical Society.

  6. [Use of fibrin glue in the prevention of leakage in pancreatico-jejunal anastomoses].

    Science.gov (United States)

    Stojanović, M; Jeremic, M; Stojanović, P; Stojiljković, M; Gmijović, D; Stanojković, Z; Savić, V; Djordjević, V; Cvetković, Z; Kostov, M; Colović, R

    2002-01-01

    The aim of this study was to test the protective effects of fibrin sealing on the pancreatico-jejunostomy (PJA), the high-risk anastomosis following pancreas head resection. Experimental study was performed on the mongrel dogs, divided in two groups (20 animals each): Experimental group-with end to end "dunking" PJA, protected by temporary occlusion of the pancreatic duct with fibrin sealant/Tissucol/Immuno Ag/, while control group was without any protective procedure. The animals were followed 5 months in order to study: protective effects of such procedure on the PJA quantified with the percent of anastomotic leakage, effects of the exocrine secretion and effects the endocrine function Results: PJA leakage occurred in 13.33% in control group. No leakage was registered in experimental group. Biochemical, histological and electron microscopic study showed slight transitory elevation of amylase levels. Fibrin glue plug was dissolved and pancreatic juice output was reestablished 12th days postoperatively. Long term follow-up showed no damages of the endocrine and exocrine pancreas. Pancreatic duct occlusion with fibrin glue appeared to be an useful method in the prevention of pancreatico-jejunostomy leakage, without negative effects on the exocrine and endocrine pancreas.

  7. Beam asymmetry Σ for π0 and η photoproduction on the proton at GlueX

    Science.gov (United States)

    Zhang, Zhenyu; GlueX Collaboration

    2016-09-01

    Measurements of meson photoproduction at high energies began almost 50 years ago with bubble chamber experiments at SLAC, DESY, and Cambridge. These data have been successfully described through Regge theory in terms of t-channel quasi-particle exchange. High statistics measurements of pseudoscalar meson photoproduction at GlueX, using the 9 GeV linearly-polarized, tagged photon beam in Jefferson Lab's Hall D, will provide important new constraints on these Regge models. These measurements will test our understanding of the photoproduction mechanism at high energy, which is a necessary first step toward the broader meson spectroscopy program at GlueX. Through finite energy sum rules, these measurements can also impose new constraints on the extraction of nucleon resonances from low energy photoproduction data. In this talk, preliminary results for the linearly polarized photon beam asymmetry Σ for the exclusive reactions γp -> pπ0 and γp -> pη will be presented. These are the first measurements of the η beam asymmetry at these energies. Supported by Jefferson Science Associates, LLC under U.S. DOE Contract No. DE-AC05-06OR23177 and the China Scholarship Council No. 201506275156.

  8. Effects of albumin/glutaraldehyde glue on healing of colonic anastomosis in rats

    Science.gov (United States)

    Despoudi, Kalliopi; Mantzoros, Ioannis; Ioannidis, Orestis; Cheva, Aggeliki; Antoniou, Nikolaos; Konstantaras, Dimitrios; Symeonidis, Savvas; Pramateftakis, Manousos George; Kotidis, Efstathios; Angelopoulos, Stamatis; Tsalis, Konstantinos

    2017-01-01

    AIM To evaluate the effect of local surgical adhesive glue (albumin/glutaraldehyde-Bioglue) on the healing of colonic anastomoses in rats. METHODS Forty Albino-Wistar male rats were randomly divided into two groups, with two subgroups of ten animals each. In the control group, an end-to-end colonic anastomosis was performed after segmental resection. In the Bioglue group, the anastomosis was protected with extraluminar application of adhesive glue containing albumin and glutaraldehyde. Half of the rats were sacrificed on the fourth and the rest on the eighth postoperative day. Anastomoses were resected and macroscopically examined. Bursting pressures were calculated and histological features were graded. Other parameters of healing, such as hydroxyproline and collagenase concentrations, were evaluated. The experimental data were summarized and computed from the results of a one-way ANOVA. Fisher’s exact test was applied to compare percentages. RESULTS Bursting pressures, adhesion formation, inflammatory cell infiltration, and collagen deposition were significantly higher on the fourth postoperative day in the albumin/glutaraldehyde group than in the control group. Furthermore, albumin/glutaraldehyde significantly increased adhesion formation, inflammatory cell infiltration, neoangiogenesis, and collagen deposition on the eighth postoperative day. There was no difference in fibroblast activity or hydroxyproline and collagenase concentrations. CONCLUSION Albumin/glutaraldehyde, when applied on colonic anastomoses, promotes their healing in rats. Therefore, the application of protective local agents in colonic anastomoses leads to better outcomes. PMID:28883693

  9. Identification and quantification of glue-like off-odors in elastic therapeutic tapes.

    Science.gov (United States)

    Denk, Philipp; Buettner, Andrea

    2018-05-01

    Elastic therapeutic tapes are an important tool in the field of physical therapy and medicine. These tapes contain types of adhesive. However, sensory evaluations revealed the release of pronounced and irritating odors of the tapes. Negative odors were, amongst others, reported in elastic therapeutic tapes containing acrylic adhesives. In this study, the odor of four different tape samples was evaluated applying a descriptive analysis approach carried out by a trained sensory panel. Afterwards, the volatile compounds were recovered from the samples by solvent extraction and isolated by solvent-assisted flavor evaporation (SAFE). The obtained distillates were subsequently analyzed by gas chromatography-olfactometry (GC-O) and two-dimensional GC-O coupled with mass spectrometry (2D-GC-MS/O). To determine the most potent odorants in the distillates, odor extract dilution analyses (OEDA) were carried out. Thirty-one odorants were successfully identified using this approach, which were all described for the first time as odorants in tapes. Amongst the set of volatiles, unsaturated and saturated aldehydes were present, eliciting fatty, soapy, and citrus-like odor impressions, as well as a range of glue-like, moldy, and fruity smelling odor-active volatiles, such as 2-ethyl-1-hexanol, butyl benzoate, and 3-phenyltoluene. Based on their relative intensities, the concentrations of the glue-like smelling substances were determined: 2-ethyl-1-hexanol, present in all samples, was determined with concentrations ranging from 10 to 200 mg/kg in the investigated tapes.

  10. The GlueX Start Counter and Beam Asymmetry$\\Sigma$ in Single $\\pi^{0}$ Photoproduction

    Energy Technology Data Exchange (ETDEWEB)

    Pooser, Eric [Florida Intl Univ., Miami, FL (United States)

    2016-03-26

    The GlueX experiment aims to study meson photoproduction while utilizing the coherent bremsstrahlung technique to produce a 9 GeV linearly polarized photon beam incident on a liquid H2 target. A Start Counter detector was fabricated to properly identify the accelerator electron beam buckets and to provide accurate timing information. The Start Counter detector was designed to operate at photon intensities of up to 108 γ/s in the coherent peak and provides a timing resolution ~300 ps so as to provide successful identification of the electron beam buckets to within 99% accuracy. Furthermore, the Start Counter detector provides excellent solid angle coverage, ~ 90% of 4π hermeticity, and a high degree of segmentation for background rejection. It consists of a cylindrical array of 30 scintillators with pointed ends that bend towards the beam at the downstream end. Magnetic field insensitive silicon photomultiplier detectors were selected as the readout system. An initial measurement of the beam asymmetry Sigma in the exclusive reaction γ$\\vec{p}$→ π0p, where π0 → γ has been carried out utilizing the GlueX spectrometer during the Spring 2015 commissioning run. The tagged photon energies ranged from 2.5≤ Eγ ≤ 3.0 GeV in the coherent peak. These measurements were then compared to the world data set and show remarkable agreement with only two hours of physics production running.

  11. Clinical observation on fibrin glue technique in pterygium surgery performed with limbal autograft transplantation

    Directory of Open Access Journals (Sweden)

    Hui Liu

    2013-07-01

    Full Text Available AIM: To compare the efficiency and safety of fibrin glue to suture technique in pterygium surgery performed with limbal autograft.METHODS: A prospective randomized clinical trial was carried out in 60 eyes of 48 patients operated for primary nasal pterygium. Autologous limbal graft taken from the superotemporal limbus was used to cover the sclera after pterygium excision under local anesthesia with 2% lidocaine. In 22 cases(30 eyes, the transplant was attached to the sclera with a fibrin tissue adhesive(group 1and in 26 cases(30 eyeswith 10-0 Virgin silk sutures(group 2. Patients were followed up at least for 3 months. Time of operation, matching degree of graft and visual analogue scale(VASscore were mainly observed and recorded. RESULTS: Patient symptoms were significantly less and biomicroscopic findings were better in group 1. Pterygium recurrence was seen in 1 case of group 1, and 1 case of group 2. Average surgery time was shorter(PCONCLUSION: Using fibrin glue for graft fixation in pterygium surgery causes significantly less postoperative pain and shortens surgery time significantly.

  12. DNA glue

    DEFF Research Database (Denmark)

    Filichev, Vyacheslav V; Astakhova, Irina V.; Malakhov, Andrei D.

    2008-01-01

    Significant alterations in thermal stability of parallel DNA triplexes and antiparallel duplexes were observed upon changing the attachment of ethynylpyrenes from para to ortho in the structure of phenylmethylglycerol inserted as a bulge into DNA (TINA). Insertions of two ortho-TINAs as a pseudo...

  13. Characterisation of a new bioadhesive system based on polysaccharides with the potential to be used as bone glue.

    Science.gov (United States)

    Hoffmann, Bettina; Volkmer, Elias; Kokott, Andreas; Augat, Peter; Ohnmacht, Michael; Sedlmayr, Nicole; Schieker, Matthias; Claes, Lutz; Mutschler, Wolf; Ziegler, Günter

    2009-10-01

    Although gluing bone is in theory a very attractive alternative to classical fracture treatment, this method is not yet clinically established due to the lack of an adhesive which would meet all the necessary requirements. We therefore developed a novel two-component bioadhesive system with the potential to be used as a bone adhesive based on biocompatible and degradable biopolymers (chitosan, oxidised dextran or starch). After mixing in water, the two components covalently cross-link by forming a Schiff's base. By the same mechanism, the glue binds to any other exposed amino group such as for example those exposed in fractured bone, even in the presence of water. Modified chitosan was synthesised from commercially available chitosan by deacetylation and was then reduced in molecular weight by heating in acid. The amount of free amino groups was analysed by IR. The molecular weight was determined by viscosimetry. Starch or dextran were oxidised with periodic acid to generate aldehyde groups, which were quantified by titration. l-Dopa was conjugated to oxidised dextran or starch in analogy to the gluing mechanism of mussels. Biomechanical studies revealed that the new glue is superior to fibrin glue, but has less adhesive strength than cyanoacrylates. In vitro cell testing demonstrated excellent biocompatibility, rendering this glue a potential candidate for clinical use.

  14. Versatile fabrication of paper-based microfluidic devices with high chemical resistance using scholar glue and magnetic masks.

    Science.gov (United States)

    Cardoso, Thiago M G; de Souza, Fabrício R; Garcia, Paulo T; Rabelo, Denilson; Henry, Charles S; Coltro, Wendell K T

    2017-06-29

    Simple methods have been developed for fabricating microfluidic paper-based analytical devices (μPADs) but few of these devices can be used with organic solvents and/or aqueous solutions containing surfactants. This study describes a simple fabrication strategy for μPADs that uses readily available scholar glue to create the hydrophobic flow barriers that are resistant to surfactants and organic solvents. Microfluidic structures were defined by magnetic masks designed with either neodymium magnets or magnetic sheets to define the patter, and structures were created by spraying an aqueous solution of glue on the paper surface. The glue-coated paper was then exposed to UV/Vis light for cross-linking to maximize chemical resistance. Examples of microzone arrays and microfluidic devices are demonstrated. μPADs fabricated with scholar glue retained their barriers when used with surfactants, organic solvents, and strong/weak acids and bases unlike common wax-printed barriers. Paper microzones and microfluidic devices were successfully used for colorimetric assays of clinically relevant analytes commonly detected in urinalysis to demonstrate the low background of the barrier material and generally applicability to sensing. The proposed fabrication method is attractive for both its ability to be used with diverse chemistries and the low cost and simplicity of the materials and process. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Bulk physicochemical, interconnectivity, and mechanical properties of calcium phosphate cements-fibrin glue composites for bone substitute applications

    NARCIS (Netherlands)

    Lopez-Heredia, M.A.; Pattipeilohy, J.; Hsu, S.; Grykien, M.; Weijden, B. van der; Leeuwenburgh, S.C.G.; Salmon, P.; Wolke, J.G.C.; Jansen, J.A.

    2013-01-01

    Calcium phosphate cements (CPCs) and fibrin glue (FG) are used for surgical applications. Their combination is promising to create bone substitutes able to promote cell attachment and bone remodeling. This study proposes a novel approach to create CPC-FG composites by simultaneous CPC setting and FG

  16. CT-guided percutaneous injection of the fibrin glue by 'double needle' technique for the treatment of sacral cysts

    International Nuclear Information System (INIS)

    Wang Ganggang; Chen Long; Yang Chao; Ni Caifang

    2013-01-01

    Objective: To analyze the efficacy and safety of CT-guided percutaneous injection of the fibrin glue by 'double needle' technique to treat sacral cyst. Methods: Clinical data of 20 cases with 'double-needle' injection of fibrin glue technology to treat sacral cyst were retrospectively analyzed. All patients had varying degrees of sacral nerve root compression symptoms. The treatment for sacral cyst was carried out after clear diagnosis was made. On the basis of CT-guided percutaneous injection of fibrin glue, the improved CT-guided percutaneous injection of fibrin glue by 'double-needle' technique was used to treat these patients. The average dose of fibrin glue was (5.9 ± 2.4) ml. The clinical results of improvement as to pain and neurological function were evaluated after follow-up of an average of 17 months. The assessment criteria were as follows: excellent, complete resolution of signs and symptoms, with the patient returning to his or her regular employment and no recurrence of cysts during 1 year of follow-up, good, symptoms and signs in the legs and perineal region resolved but with persistent pain in the lumbosacral region, which did not interfere with the patient's regular work (the cysts did not recur for 6 months during follow-up), fair, no improvement in clinical symptoms, but a decrease in cyst size on the imaging study, poor, no improvement in clinical symptoms and no observed changes in cyst size in imaging studies or recurrence. Results: Most patients experienced some degree of pain relief and functional improvement after fibrin glue therapy, with most experiencing complete or marked resolution of clinical symptoms. Nine patients reported excellent recovery, 8 reported good recovery, 2 reported fair recovery, and 1 reported poor recovery. The overall percentage of positive outcomes (excellent and good recovery) was 85%. No serious postoperative complications were discovered. Conclusions: CT guided percutaneous injection of the fibrin glue by

  17. Preliminary report of a sutureless onlay technique for incisional hernia repair using fibrin glue alone for mesh fixation.

    Science.gov (United States)

    Stoikes, Nathaniel; Webb, David; Powell, Ben; Voeller, Guy

    2013-11-01

    The Rives repair for ventral/incisional (V/I) hernias involves sublay mesh placement requiring retrorectus dissection and transfascial stitches. Chevrel described a repair by onlaying mesh after a unique primary fascial closure. Although Chevrel fixated mesh to the anterior fascia with sutures, he used fibrin glue for fascial closure reinforcement. We describe an onlay technique with mesh fixated to the anterior fascia solely with fibrin glue without suture fixation. From January 2010 to January 2012, 50 patients underwent a V/I hernia onlay technique with fibrin glue mesh fixation. Records were reviewed for technical details, demographics, mesh characteristics, and postoperative outcomes. Primary fascial closure with interrupted permanent suture was done with or without myofascial advancement flaps. Onlay polypropylene mesh was placed providing 8 cm of overlap. Fibrin glue was applied over the prosthesis and subcutaneous drains were placed. Mean age was 62.4 years. Mean body mass index was 30.1 kg/m(2). Average mesh size was 14.5 cm × 19.1 cm. Mean operative time was 144.4 minutes (range, 38 to 316 minutes). Mean discharge was postoperative Day 2.9 (range, 0 to 15 days). Morbidity included eight seromas, one hematoma, and three wound infections. Seventeen patients required components separation. Mean follow-up was 19.5 months with no recurrences. This is the first series describing fibrin glue alone for mesh fixation for V/I hernia repair. It allows for immediate prosthesis fixation to the anterior fascia. Early results are promising. Potential advantages include less operative time, less technical difficulty, and less long-term pain. A prospective trial is needed to evaluate this approach.

  18. Experimental Status of Exotic Mesons and the GlueX Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Daniel Carman

    2006-10-22

    One of the unanswered and most fundamental questions in physics regards the nature of the confinement mechanism of quarks and gluons in QCD. Exotic hybrid mesons manifest gluonic degrees of freedom and their spectroscopy will provide the data necessary to test assumptions in lattice QCD and the specific phenomenology leading to confinement. Within the past two decades a number of experiments have put forth tantalizing evidence for the existence of exotic hybrid mesons in the mass range below 2 GeV. This talk represents an overview of the available data and what has been learned. In looking toward the future, the GlueX experiment at Jefferson Laboratory represents a new initiative that will perform detailed spectroscopy of the light-quark meson spectrum. This experiment and its capabilities will be reviewed.

  19. Comparison of a plasma-based composite biologic sealant with fibrin glue (Tisseel) for vascular anastomoses.

    Science.gov (United States)

    Doillon, Charles J; Dion, Yves-Marie

    2004-12-01

    Biologic sealants are needed in numerous, more and more demanding, procedures--especially with developments occurring in endovascular and laparoscopic vascular techniques. An initial pilot study in dogs showed that a 4-cm aortotomy closed with a polyester patch sutured in place by a 4-mm-spaced running suture consistently led to massive hemorrhage. We then designed a study using five dogs where two aortotomies were done to compare the effect of Tisseel to that of an autologous sealant prepared in our laboratory. Arterial pressures and heparinization were maintained throughout the surgical procedure. Both biologic sealants prevented hemorrhage from the arteriotomy at unclamping. Macroscopic and histologic assessments were performed. At killing, one week later, the autologous sealant exhibited less blood saturation of the collagen sponge compared with Tisseel. The use of autologous plasma combined with other adhesive components could be an efficient alternative to allogenic fibrin glue. Further studies are needed to confirm these observations.

  20. A New Potential Cause in the Development of Toxic Anterior Segment Syndrome: Fibrin Glue

    Directory of Open Access Journals (Sweden)

    Selçuk Sızmaz

    2014-08-01

    Full Text Available Objectives: To present a potential cause for toxic anterior segment syndrome (TASS. Materials and Methods: We report 4 cases of TASS that occurred following uneventful phacoemulsification and intraocular lens implantation. Results: The 4 cases were the first consecutive 2 cases of 2 different surgery days, 5 months apart. The most prominent sign of TASS was limbus-to-limbus corneal edema. Pain and/or intraocular pressure rise were also common. All surgical and presurgical procedures were checked after the first outbreak, whereas the second outbreak required further investigation. Fibrin glue remnants from preceding pterygium surgery with conjunctival autografting were found to be the potential cause. Despite intensive corticosteroid therapy, corneal edema did not resolve in 2 patients who underwent keratoplasty. Conclusion: TASS is a sight-threatening condition which requires thorough investigation for prevention of new cases. All steps must be carefully revised. (Turk J Ophthalmol 2014; 44: 280-3

  1. Uncertainty assessment of integrated distributed hydrological models using GLUE with Markov chain Monte Carlo sampling

    DEFF Research Database (Denmark)

    Blasone, Roberta-Serena; Madsen, Henrik; Rosbjerg, Dan

    2008-01-01

    uncertainty estimation (GLUE) procedure based on Markov chain Monte Carlo sampling is applied in order to improve the performance of the methodology in estimating parameters and posterior output distributions. The description of the spatial variations of the hydrological processes is accounted for by defining......In recent years, there has been an increase in the application of distributed, physically-based and integrated hydrological models. Many questions regarding how to properly calibrate and validate distributed models and assess the uncertainty of the estimated parameters and the spatially......-site validation must complement the usual time validation. In this study, we develop, through an application, a comprehensive framework for multi-criteria calibration and uncertainty assessment of distributed physically-based, integrated hydrological models. A revised version of the generalized likelihood...

  2. Fibrin glue as the cell-delivery vehicle for mesenchymal stromal cells in regenerative medicine.

    Science.gov (United States)

    Wu, Xiuwen; Ren, Jianan; Li, Jieshou

    2012-05-01

    The use of tissue-engineering techniques such as stem-cell therapy to renew injured tissues is a promising strategy in regenerative medicine. As a cell-delivery vehicle, fibrin glues (FG) facilitate cell attachment, growth and differentiation and, ultimately, tissue formation and organization by its three-dimensional structure. Numerous studies have provided evidence that stromal cells derived from bone marrow (bone marrow stromal cells; BMSC) and adipose tissue (adipose-derived stromal cells; ADSC) contain a population of adult multipotent mesenchymal stromal cells (MSC) and endothelial progenitor cells that can differentiate into several lineages. By combining MSC with FG, the implantation could take advantage of the mutual benefits. Researchers and physicians have pinned their hopes on stem cells for developing novel approaches in regenerative medicine. This review focuses on the therapeutic potential of MSC with FG in bone defect reconstruction, cartilage and tendon injury repair, ligament, heart and nerve regeneration, and, furthermore, wound healing.

  3. Zwitterionic Nanofibers of Super-Glue for Transparent and Biocompatible Multi-Purpose Coatings

    Science.gov (United States)

    Mele, Elisa; Heredia-Guerrero, José A.; Bayer, Ilker S.; Ciofani, Gianni; Genchi, Giada G.; Ceseracciu, Luca; Davis, Alexander; Papadopoulou, Evie L.; Barthel, Markus J.; Marini, Lara; Ruffilli, Roberta; Athanassiou, Athanassia

    2015-09-01

    Here we show that macrozwitterions of poly(ethyl 2-cyanoacrylate), commonly called Super Glue, can easily assemble into long and well defined fibers by electrospinning. The resulting fibrous networks are thermally treated on glass in order to create transparent coatings whose superficial morphology recalls the organization of the initial electrospun mats. These textured coatings are characterized by low liquid adhesion and anti-staining performance. Furthermore, the low friction coefficient and excellent scratch resistance make them attractive as solid lubricants. The inherent texture of the coatings positively affects their biocompatibility. In fact, they are able to promote the proliferation and differentiation of myoblast stem cells. Optically-transparent and biocompatible coatings that simultaneously possess characteristics of low water contact angle hysteresis, low friction and mechanical robustness can find application in a wide range of technological sectors, from the construction and automotive industries to electronic and biomedical devices.

  4. Glue Ear, Hearing Loss and IQ: An Association Moderated by the Child’s Home Environment

    Science.gov (United States)

    Hall, Amanda J.; Maw, Richard; Midgley, Elizabeth; Golding, Jean; Steer, Colin

    2014-01-01

    Background Glue ear or otitis media with effusion (OME) is common in children and may be associated with hearing loss (HL). For most children it has no long lasting effects on cognitive development but it is unclear whether there are subgroups at higher risk of sequelae. Objectives To examine the association between a score comprising the number of times a child had OME and HL (OME/HL score) in the first four/five years of life and IQ at age 4 and 8. To examine whether any association between OME/HL and IQ is moderated by socioeconomic, child or family factors. Methods Prospective, longitudinal cohort study: the Avon Longitudinal Study of Parents and Children (ALSPAC). 1155 children tested using tympanometry on up to nine occasions and hearing for speech (word recognition) on up to three occasions between age 8 months and 5 years. An OME/HL score was created and associations with IQ at ages 4 and 8 were examined. Potential moderators included a measure of the child’s cognitive stimulation at home (HOME score). Results For the whole sample at age 4 the group with the highest 10% OME/HL scores had performance IQ 5 points lower [95% CI −9, −1] and verbal IQ 6 points lower [95% CI −10, −3] than the unaffected group. By age 8 the evidence for group differences was weak. There were significant interactions between OME/HL and the HOME score: those with high OME/HL scores and low 18 month HOME scores had lower IQ at age 4 and 8 than those with high OME/HL scores and high HOME scores. Adjusted mean differences ranged from 5 to 8 IQ points at age 4 and 8. Conclusions The cognitive development of children from homes with lower levels of cognitive stimulation is susceptible to the effects of glue ear and hearing loss. PMID:24498289

  5. Tolerance of glue embolization under local anesthesia in varicoceles: A comparative study of two different cyanoacrylates

    Energy Technology Data Exchange (ETDEWEB)

    Vanlangenhove, Peter, E-mail: peter.vanlangenhove@uzgent.be [Department of Vascular and Interventional Radiology, Ghent University Hospital, De Pintelaan 185, 9000 Ghent (Belgium); Everaert, Karel [Department of Urology, Ghent University Hospital, De Pintelaan 185, 9000 Ghent (Belgium); Van Maele, Georges [Department of Statistics, Ghent University Hospital, De Pintelaan 185, 9000 Ghent (Belgium); Defreyne, Luc [Department of Vascular and Interventional Radiology, Ghent University Hospital, De Pintelaan 185, 9000 Ghent (Belgium)

    2014-03-15

    Purpose: To find out whether in varicocele embolization the copolymer cyanoacrylate glue (NBCA-MS) has a better patient tolerance compared to the monomer n-butyl-2-cyanoacrylate (NBCA). Materials and methods: N = 112 insufficient spermatic veins (left sided N = 84, right sided N = 28) diagnosed in N = 83 adult males were prospectively randomized for blinded embolization with either NBCA N = 54 (Histoacryl) or with NBCA-MS N = 58 (Glubran2). Before, during and up to one week after embolization, patient discomfort was assessed by a standardized pain scale. Type, location and side of discomfort were noted. Statistical analysis was performed with the Mann–Whitney U-test, the McNemar test and the Fisher's exact test. Results: Embolization caused discomfort in N = 48/112 (43%) spermatic veins, comprising N = 26/54 (48%) in the NBCA group and N = 22/58 (38%) in the NBCA-MS group. During the week after embolization, the overall number of discomfort reports rose to N = 62/106 (59%), with an increase to N = 30/53 (57%) in the NBCA group and to N = 32/53 (60%) in the NBCA-MS group. The number of immediate grade 2 to 4 pain reactions was N = 22/112 (20%), and rose to N = 37/106 (35%) after one week. No difference in discomfort during embolization and at 1 week after treatment was noted. Characteristics, severity grading, and location of discomfort were similar in both NBCA groups, regardless the time point of observation. Conclusion: Discomfort after glue embolization of varicocele is a common side effect, which might evolve to pain. The assumed lower inflammatory reaction on NBCA-MS was not translated in an improved tolerance.

  6. Pain experience during internal spermatic vein embolization for varicocele: comparison of two cyanoacrylate glues

    Energy Technology Data Exchange (ETDEWEB)

    Heye, Sam; Maleux, Geert; Wilms, Guido [University Hospital Gasthuisberg, Department of Radiology, Leuven (Belgium)

    2006-01-01

    The purpose of this study was to evaluate possible pain sensation differences in patients after retrograde varicocele embolization either with n-butyl-(2)-cyanoacrylate (NBCA) or with n-butyl-(2)-cyanoacrylate + methacryloxysulfolane (NBCA-MS). Transcatheter varicocele embolization was performed in 64 consecutive patients (62 left, two bilateral). Embolization was done with NBCA (n=32) or NBCA-MS (n=32). Immediately after the procedure, patients were asked to evaluate pain during embolization using a visual analog scale (VAS). Statistical analysis was done with Student's t test. Mean pain score on VAS was 3.23 (range: 0-8) for NBCA and 3.28 (range 0-9) for NBCA-MS. This difference was not significant (P=0.932). Independently of the type of glue, no difference in pain sensation (P value 0.421) was found between patients younger than 18 (n=29) and patients older than 18 years of age (n=35) (younger than18, mean 3.52; older than 18, mean 3.05). No difference in mean pain experience level (P=0.323) was seen in 11 patients with vessel wall perforation (23.4%) during the procedure (3.89; range: 0-8.5) in comparison with those without perforation (mean pain sensation level: 3.13; range: 0-9). No difference in pain experience was found after transcatheter varicocele embolization either with NBCA or NBCA-MS. Age and vessel wall perforation have no influence on pain sensation independently of the type of glue. (orig.)

  7. Pain experience during internal spermatic vein embolization for varicocele: comparison of two cyanoacrylate glues

    International Nuclear Information System (INIS)

    Heye, Sam; Maleux, Geert; Wilms, Guido

    2006-01-01

    The purpose of this study was to evaluate possible pain sensation differences in patients after retrograde varicocele embolization either with n-butyl-(2)-cyanoacrylate (NBCA) or with n-butyl-(2)-cyanoacrylate + methacryloxysulfolane (NBCA-MS). Transcatheter varicocele embolization was performed in 64 consecutive patients (62 left, two bilateral). Embolization was done with NBCA (n=32) or NBCA-MS (n=32). Immediately after the procedure, patients were asked to evaluate pain during embolization using a visual analog scale (VAS). Statistical analysis was done with Student's t test. Mean pain score on VAS was 3.23 (range: 0-8) for NBCA and 3.28 (range 0-9) for NBCA-MS. This difference was not significant (P=0.932). Independently of the type of glue, no difference in pain sensation (P value 0.421) was found between patients younger than 18 (n=29) and patients older than 18 years of age (n=35) (younger than18, mean 3.52; older than 18, mean 3.05). No difference in mean pain experience level (P=0.323) was seen in 11 patients with vessel wall perforation (23.4%) during the procedure (3.89; range: 0-8.5) in comparison with those without perforation (mean pain sensation level: 3.13; range: 0-9). No difference in pain experience was found after transcatheter varicocele embolization either with NBCA or NBCA-MS. Age and vessel wall perforation have no influence on pain sensation independently of the type of glue. (orig.)

  8. SU-F-T-141: Proton Dose Validation in a Phantom Beyond TRUFILL N-BCA Embolization Glue

    International Nuclear Information System (INIS)

    Mandapaka, A; Ghebremedhin, A; Patyal, B; Linda, Loma

    2016-01-01

    Purpose: To validate the treatment planning system predicted proton dose beyond a heterogeneity (n-BCA glue) by making a measurement in a custom acrylic phantom. Methods: A custom cubic acrylic phantom was designed for this experiment. A container was designed to fit in the phantom. This container was filled with TRUFILL™ n-Butyl Cyanoacrylate(n-BCA) glue. When the container was placed in the phantom, its center was at a distance of 7.4cm from the entrance. This depth allows us to make measurements around the center of modulation of a 126 MeV proton beam with a 3cm spread-out-Bragg peak. To make measurements at other beam energies, additional acrylic can be added in front of the phantom, to adjust the depth of the heterogeneity. A diamond detector was cross calibrated against a standard cylindrical ion chamber in a 126MeV beam. The diamond detector was then used to make dose measurements beyond the inhomogeneity. The measurement was repeated with the container filled with water. Several measurements were made at each setup, to check reproducibility of measurements. Results: For the same number of Tic3R1 counts, the dose measured with the diamond detector beyond n-BCA glue was 1.053 times the dose measured beyond the water filled container. This result is in agreement with the measured stopping power of glue (1.06). These measurements were in agreement with the dose predicted by the treatment planning system when the electron density of the heterogeneity was replaced with 1.06 before the dose calculation. Conclusion: Our initial measurements validate the dose predicted by our treatment plan in the presence of heterogeneity in a phantom. The material tested (n-BCA glue) is commonly used in the treatment of AVM’s prior to an SRS treatment. An error in dose predicted by the treatment plan in the presence of the glue can be detrimental in a single fraction high dose SRS treatment I received the n-BCA liquid embolic system samples from Codman and Shurtleff, Inc.

  9. SU-F-T-141: Proton Dose Validation in a Phantom Beyond TRUFILL N-BCA Embolization Glue

    Energy Technology Data Exchange (ETDEWEB)

    Mandapaka, A; Ghebremedhin, A; Patyal, B; Linda, Loma [University Medical Center, Loma Linda, CA (United States)

    2016-06-15

    Purpose: To validate the treatment planning system predicted proton dose beyond a heterogeneity (n-BCA glue) by making a measurement in a custom acrylic phantom. Methods: A custom cubic acrylic phantom was designed for this experiment. A container was designed to fit in the phantom. This container was filled with TRUFILL™ n-Butyl Cyanoacrylate(n-BCA) glue. When the container was placed in the phantom, its center was at a distance of 7.4cm from the entrance. This depth allows us to make measurements around the center of modulation of a 126 MeV proton beam with a 3cm spread-out-Bragg peak. To make measurements at other beam energies, additional acrylic can be added in front of the phantom, to adjust the depth of the heterogeneity. A diamond detector was cross calibrated against a standard cylindrical ion chamber in a 126MeV beam. The diamond detector was then used to make dose measurements beyond the inhomogeneity. The measurement was repeated with the container filled with water. Several measurements were made at each setup, to check reproducibility of measurements. Results: For the same number of Tic3R1 counts, the dose measured with the diamond detector beyond n-BCA glue was 1.053 times the dose measured beyond the water filled container. This result is in agreement with the measured stopping power of glue (1.06). These measurements were in agreement with the dose predicted by the treatment planning system when the electron density of the heterogeneity was replaced with 1.06 before the dose calculation. Conclusion: Our initial measurements validate the dose predicted by our treatment plan in the presence of heterogeneity in a phantom. The material tested (n-BCA glue) is commonly used in the treatment of AVM’s prior to an SRS treatment. An error in dose predicted by the treatment plan in the presence of the glue can be detrimental in a single fraction high dose SRS treatment I received the n-BCA liquid embolic system samples from Codman and Shurtleff, Inc.

  10. Migration to the GLUE 2.0 information schema in the LCG/EGEE/EGI production Grid

    International Nuclear Information System (INIS)

    Burke, Stephen; Field, Laurence; Horat, David

    2011-01-01

    The GLUE information schema has been in use in the LCG/EGEE production Grid since the first version was released in 2002. In 2008 a major redesign of GLUE, version 2.0, was defined in the context of the Open Grid Forum. The implementation of the publication and use of the new schema is a complex process which needs to be carefully managed to avoid any disruption to the production service, especially in the light of the end of the EGEE project and the transition to the new middleware and operational structures in EGI. In this paper we discuss the LDAP rendering of the schema, the upgrading of the Grid information system to allow both schemas to be used in parallel, the design and rollout of information providers, and the plans for migrating client software which uses the schema information. In particular we consider the implications for the specific requirements of the LCG project, especially regarding storage systems, accounting and monitoring.

  11. Humidity control and hydrophilic glue coating applied to mounted protein crystals improves X-ray diffraction experiments

    Science.gov (United States)

    Baba, Seiki; Hoshino, Takeshi; Ito, Len; Kumasaka, Takashi

    2013-01-01

    Protein crystals are fragile, and it is sometimes difficult to find conditions suitable for handling and cryocooling the crystals before conducting X-ray diffraction experiments. To overcome this issue, a protein crystal-mounting method has been developed that involves a water-soluble polymer and controlled humid air that can adjust the moisture content of a mounted crystal. By coating crystals with polymer glue and exposing them to controlled humid air, the crystals were stable at room temperature and were cryocooled under optimized humidity. Moreover, the glue-coated crystals reproducibly showed gradual transformations of their lattice constants in response to a change in humidity; thus, using this method, a series of isomorphous crystals can be prepared. This technique is valuable when working on fragile protein crystals, including membrane proteins, and will also be useful for multi-crystal data collection. PMID:23999307

  12. Endovascular Treatment of Pseudoaneurysm of the Common Hepatic Artery with Intra-aneurysmal Glue (N-Butyl 2-Cyanoacrylate) Embolization

    International Nuclear Information System (INIS)

    Garg, Ashwin; Banait, Swati; Babhad, Sudeep; Kanchankar, Niraj; Nimade, Pradeep; Panchal, Chintan

    2007-01-01

    A 40-year-old man, a chronic alcoholic, presented with acute epigastric pain. Selective celiac arteriography showed a pseudoaneurysm arising from the common hepatic artery. We hereby describe a technical innovation where complete pseudoaneurysm exclusion was seen after intra-aneurysmal N-butyl 2-cyanoacrylate (glue) injection with preservation of antegrade hepatic arterial flow and conclude that intra-aneurysmal liquid injection may have potential as a therapeutic option to reconstruct a defective vessel wall and thereby maintain the antegrade flow

  13. GLUE Analysis and Optimal Operation for Diyala River Basin in Iraq Using Variable Infiltration Capacity Model

    Science.gov (United States)

    Waheed, S., Sr.; Ramirez, J.

    2017-12-01

    Uncertainty in both hydrologic behavior and model characterization is a concern for current and future water resource system planning, operation, and management. To develop optimal dam operation schemes under future uncertainty, the sensitivity of the precipitation-runoff response to changes in hydro-climatic forcing must be quantified. To achieve this purpose, accurate (observational and modeled) data should be implemented. Herein, many data sources were compared to representative hydrologic datasets. Due to limited availability of observed daily data, a random temporal cascade method was used to downscale the monthly precipitation into daily. Then, four interpolation methods were compared to transform the point into gridded data. Furthermore, a regression technique coupled with Kriging method was developed. The method is based on regressing modeled data (from VIC dataset) with the observed gridded temperature by relating the regression to the geometry of each grid. The sensitivity and identifiability of the Variable Infiltration Capacity model (VIC) for the Diyala River basin in Iraq were evaluated using GLUE technique. Diyala River is a Tigris River tributary in eastern Iraq. Its total length and basin area are about 216.5 km and 16,763.7 km2, respectively. Seven candidate parameters of VIC model (b_infilt, Ds, Ws, Dsmax, and depths of soil layer 1, 2, and 3) associated with the infiltration and surface runoff production processes are examined for 14000 random sets. The comparison between the different data showed that neither the observations from Tropical Rainfall Measurement Mission nor the VIC modeled data is accurate for gridded precipitation; therefore, a downscaling technique was applied. Moreover, the comparison between four different interpolation techniques revealed that the Kriging method is the most accurate. The optimal model performance was found to be 0.731 NSCE. Also, the GLUE analysis results implied that the depth of the second soil layer depth

  14. Development of Self Fire Retardant Melamine-Animal Glue Formaldehyde (MGF) Resin for the Manufacture of BWR Ply Board

    Science.gov (United States)

    Khatua, Pijus Kanti; Dubey, Rajib Kumar; Roymahapatra, Gourisankar; Mishra, Anjan; Shahoo, Shadhu Charan; Kalawate, Aparna

    2017-10-01

    Wood is one of the most sustainable, naturally growing materials that consist mainly of combustible organic carbon compounds. Since plywood are widely used nowadays especially in buildings, furniture and cabinets. Too often the fire behavior of ply-board may be viewed as a drawback. Amino-plastic based thermosetting resin adhesives are the important and most widely used in the plywood panel industries. The fire retardant property of wood panel products by adding animal glue as an additive in the form of MGF resin and used as substitute of melamine for manufacture of plywood. Environment concerns and higher cost of petroleum based resins have resulted in the development of technologies to replace melamine partially by biomaterials for the manufacturing of resin adhesive. Natural bio-based materials such as tannin, CNSL (cardanol), lignin, soya etc. are used as partial substitution of melamine. This article presents the development of melamine-animal glue formaldehyde resin as plywood binder. About 30 % melamine was substituted by animal glue and optimized. The different physico-mechanical and fire retardant property properties tested as per IS: 1734-1983 and IS: 5509-2000 respectively are quite satisfactory. The production of adhesive from melamine with compatible natural proteinous material is cost effective, eco-friendly and enhance the fire retardant property.

  15. Transarterial microcatheter glue embolization of the bronchial artery for life-threatening hemoptysis: Technical and clinical results

    Energy Technology Data Exchange (ETDEWEB)

    Baltacioglu, Feyyaz [Marmara University School of Medicine, Department of Radiology, Istanbul (Turkey)], E-mail: fbaltaci@yahoo.com; Cimsit, Nuri Cagatay [Marmara University School of Medicine, Department of Radiology, Istanbul (Turkey)], E-mail: cagataycimsit@gmail.com; Bostanci, Korkut [Marmara University School of Medicine, Department of Thoracic Surgery, Istanbul (Turkey)], E-mail: kbostanci@marmara.edu.tr; Yueksel, Mustafa [Marmara University School of Medicine, Department of Thoracic Surgery, Istanbul (Turkey)], E-mail: myuksel@marmara.edu.tr; Kodalli, Nihat [Marmara University School of Medicine, Department of Radiology, Istanbul (Turkey)], E-mail: nihatkodalli@yahoo.com

    2010-02-15

    Objectives: To report our experience with transarterial glue embolization of the bronchial artery for life-threatening hemoptysis. Materials and methods: Twenty-five patients underwent bronchial artery embolization, using coaxial microcatheter technique, with a liquid agent, n-butyl-2-cyanoacrylate (NBCA), named glue, for life-threatening hemoptysis. The technical and clinical outcomes were followed in terms of immediate control of bleeding, recurrence of hemoptysis and complications of the procedure. Results: Four patients had acute hemoptysis when they were evaluated. The average number of arteries embolized per patient was 2.9. BAEs were successful in controlling hemoptysis immediately in all 25 patients (100%) and in 24 patients (96%) at 1 month follow-ups. One patient had recurrent hemoptysis on the tenth day after embolization. The follow-up time ranged from 2 to 63 months (mean 14 months). Six patients (25%) died all as a result of their disease process. Bleeding recurred in 3 patients after 30 days (7th, 11th, 12th months). One patient had vomitting attacks with dysphagia after the procedure that lasted 24 h. Three patients had transient thoracic pain lasting 3-5 days. There were no procedure related spinal or vascular complications. Conclusions: Glue embolization with microcatheter technique is a safe and effective treatment in cases of life-threatening hemoptysis with a very high rate of success and low rate of complications.

  16. Percutaneous sclerotherapy of massive macrocystic lymphatic malformations of the face and neck using fibrin glue with OK-432 and bleomycin.

    Science.gov (United States)

    Chen, W-l; Huang, Z-q; Chai, Q; Zhang, D-m; Wang, Y-y; Wang, H-j; Wang, L; Fan, S

    2011-06-01

    Picibanil (OK-432) and bleomycin have been used as alternative sclerosing agents for lymphatic malformations. This study evaluated the clinical curative effect of sclerotherapy using fibrin glue combined with OK-432 and bleomycin for the treatment of macrocystic lymphatic malformations of the face and neck. Fifteen paediatric patients (6 males; 9 females, aged 13 months to 14 years) who had received percutaneous sclerotherapy for massive macrocystic lymphatic malformations of the face and neck were retrospectively reviewed. Affected regions included the neck, parotid region and parapharynx, mouth floor, face and cheek, and orbital regions. All patients showed preoperative symptoms of space-occupying lesions between 4 cm × 5 cm and 12 cm × 16 cm in size. Fibrin glue with OK-432 and bleomycin was injected under general anaesthesia. All patients received preoperative and follow-up CT scans. Outcomes were assessed by three surgeons. All patients exhibited mid-facial swelling for 3-4 weeks after surgery, but no major complications. Follow-up periods ranged from 8 to 16 months. Eight lesions were completely involuted, five were mostly involuted, and two were partially involuted. Percutaneous sclerotherapy using fibrin glue with OK-432 and bleomycin provided a simple, safe, and reliable alternative treatment for massive macrocystic lymphatic malformations of the face and neck. Copyright © 2011 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  17. Effect of fibrin glue derived from snake venom on the viability of autogenous split-thickness skin graft

    Directory of Open Access Journals (Sweden)

    S.C. Rahal

    2004-01-01

    Full Text Available The aim of this study was to analyze the effect of snake venom derived from fibrin glue on the viability of split-thickness skin graft. Nine crossbreed dogs were used. Full-thickness skin segments measuring 4 x 4 cm were bilaterally excised from the proximal radial area on each dog. A split-thickness skin graft was harvestedfrom left lateral thoracic area using a freehand graft knife, and was secured to the left recipient bed using several simple interrupted sutures of 3-0 nylon (sutured graft. A split-thickness skin graft was harvested from the right lateral thoracic area using a graft knife. Fibrin glue derived from snake venom was applied to the recipient bed, and 8 equidistant simple interrupted sutures of 3-0 nylon were used to secure the skin graft (glued graft. Viable and nonviable areas were traced on a transparent sheet and measured using a Nikon Photomicroscope connected to a KS-300 image analysis system. The skin graft and recipient bed were collected from three dogs at day 7, 15, and 30 postoperative. The glued grafts had statistically higher graft viability than sutured grafts. Histological examination showed that the tissue repair process in the glued grafts was more accentuated than sutured grafts. It was possible to conclude that fibrin glue derived from snake venom increased survival of autogenous split-thickness skin graft.

  18. 2-octyl-cyanoacrylate glue for fixation of STSG in genitourinary tissue defects due to Fournier gangrene: a preliminary trial.

    Science.gov (United States)

    Sivrioğlu, Nazan; Irkören, Saime; Ceylan, Ender; Sonel, Ali Murat; Copçu, Eray

    2013-05-01

    In these reported cases, we observed the outcomes of skin take and wound healing using 2-octyl-cyanoacrylate glue, which was used as tissue glue in the reconstruction of complex genital skin loss due to fournier gangrene. Fifteen patients with Fournier's gangrene were treated in this study. After initial surgical debridement, all defects were repaired using STSG. In this method a thin layer of 2-octyl-cyanoacrylate was dripped on the recipient site immediately before graft application. All wounds were followed up postoperatively and observed for evidence of graft take, seroma or hematoma formation, drainage, and infection. Patient and physician satisfaction were also determined. Grafts were completely accepted in all fifteen patients. None of the patients had wound infection, seroma, hematoma, or other complications. Use of 2-octyl-cyanoacrylate glue (Glueseal) for STSG fixation in complex genital skin defects after Fournier gangrene may be an acceptable alternative to conventional surgical closure with a good cosmetic outcome. Further studies are needed to confirm our initial success with this approach.

  19. Humidity control and hydrophilic glue coating applied to mounted protein crystals improves X-ray diffraction experiments

    International Nuclear Information System (INIS)

    Baba, Seiki; Hoshino, Takeshi; Ito, Len; Kumasaka, Takashi

    2013-01-01

    A new crystal-mounting method has been developed that involves a combination of controlled humid air and polymer glue for crystal coating. This method is particularly useful when applied to fragile protein crystals that are known to be sensitive to subtle changes in their physicochemical environment. Protein crystals are fragile, and it is sometimes difficult to find conditions suitable for handling and cryocooling the crystals before conducting X-ray diffraction experiments. To overcome this issue, a protein crystal-mounting method has been developed that involves a water-soluble polymer and controlled humid air that can adjust the moisture content of a mounted crystal. By coating crystals with polymer glue and exposing them to controlled humid air, the crystals were stable at room temperature and were cryocooled under optimized humidity. Moreover, the glue-coated crystals reproducibly showed gradual transformations of their lattice constants in response to a change in humidity; thus, using this method, a series of isomorphous crystals can be prepared. This technique is valuable when working on fragile protein crystals, including membrane proteins, and will also be useful for multi-crystal data collection

  20. Humidity control and hydrophilic glue coating applied to mounted protein crystals improves X-ray diffraction experiments

    Energy Technology Data Exchange (ETDEWEB)

    Baba, Seiki; Hoshino, Takeshi; Ito, Len; Kumasaka, Takashi, E-mail: kumasaka@spring8.or.jp [Japan Synchrotron Radiation Research Institute (JASRI/SPring-8), 1-1-1 Kouto, Sayo, Hyogo 679-5198 (Japan)

    2013-09-01

    A new crystal-mounting method has been developed that involves a combination of controlled humid air and polymer glue for crystal coating. This method is particularly useful when applied to fragile protein crystals that are known to be sensitive to subtle changes in their physicochemical environment. Protein crystals are fragile, and it is sometimes difficult to find conditions suitable for handling and cryocooling the crystals before conducting X-ray diffraction experiments. To overcome this issue, a protein crystal-mounting method has been developed that involves a water-soluble polymer and controlled humid air that can adjust the moisture content of a mounted crystal. By coating crystals with polymer glue and exposing them to controlled humid air, the crystals were stable at room temperature and were cryocooled under optimized humidity. Moreover, the glue-coated crystals reproducibly showed gradual transformations of their lattice constants in response to a change in humidity; thus, using this method, a series of isomorphous crystals can be prepared. This technique is valuable when working on fragile protein crystals, including membrane proteins, and will also be useful for multi-crystal data collection.

  1. Experiences with the GLUE information schema in the LCG/EGEE production grid

    International Nuclear Information System (INIS)

    Burke, S; Andreozzi, S; Field, L

    2008-01-01

    A common information schema for the description of Grid resources and services is an essential requirement for interoperating Grid infrastructures, and its implementation interacts with every Grid component. In this context, the GLUE information schema was originally defined in 2002 as a joint project between the European DataGrid and DataTAG projects and the US iVDGL. The schema has major components to describe Computing and Storage Elements, and also generic Service and Site information. It has been used extensively in the LCG/EGEE Grid, for job submission, data management, service discovery and monitoring. In this paper we present the experience gained over the last five years, highlighting both successes and problems. In particular, we consider the importance of having a clear definition of schema attributes; the construction of standard information providers and difficulties encountered in mapping an abstract schema to diverse real systems; the configuration of publication in a way which suits system managers and the varying characteristics of Grid sites; the validation of published information; the ways in which information can be used (and misused) by Grid services and users; and issues related to managing schema upgrades in a large distributed system

  2. GlueX: The Search for Gluonic Excitations at Jefferson Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    D.S. Carman

    2005-08-21

    One of the unanswered and most fundamental questions in physics regards the nature of the confinement mechanism of quarks and gluons in quantum chromodynamics (QCD). Exotic hybrid mesons manifest gluonic degrees of freedom and their detailed spectroscopy will provide the precision data necessary to test assumptions in lattice QCD and the specific phenomenology leading to confinement. Photoproduction is expected to be a particularly effective manner to produce exotic hybrids, however, existing data using photon beams are sparse. At Jefferson Laboratory, plans are underway by the GlueX Collaboration to use the coherent bremsstrahlung technique to produce a linearly polarized photon beam. A solenoid-based hermetic detector will be used to collect data on meson production and decays with statistics that will exceed existing photoproduction data by several orders of magnitude after the first year of running. In order to reach the ideal photon energy of 9 GeV required for these studies, the energy of the Jefferson Laboratory electron accelerator, CEBAF, will be doubled from its current maximum energy of 6 GeV to 12 GeV. The physics motivating the search and the status of the project are reviewed.

  3. Calibrations for charged particle tracking and measurements of w photoproduction with the GlueX detector

    Energy Technology Data Exchange (ETDEWEB)

    Staib, Michael [Carnegie Mellon Univ., Pittsburgh, PA (United States)

    2017-09-21

    The GlueX experiment is a new experimental facility at Jefferson Lab in Newport News, VA. The experiment aims to map out the spectrum of hybrid mesons in the light quark sector. Measurements of the spin-density matrix elements in omega photoproduction are performed with a linear polarized photon beam on an unpolarized proton target, and presented in bins of Mandelstam t for beam energies of 8.4-9.0 GeV. The spin-density matrix elements are exclusively measured through two decays of the omega meson: omega -> pi^+ pi^- pi^0 and omega ->pi^0 gamma. A description of the experimental apparatus is presented. Several methods used in the calibration of the charged particle tracking system are described. These measurements greatly improve the world statistics in this energy range. These are the first results measured through the omega ->pi^0 gamma decay at this energy. Results are generally consistent with a theoretical model based on diffractive production with Pomeron and pseudoscalar exchange in the t-channel.

  4. Experimental study on the viscosity and adhesive performance of exogenous liquid fibrin glue.

    Science.gov (United States)

    Hayashi, Takuro; Hasegawa, Mitsuhiro; Inamasu, Joji; Adachi, Kazuhide; Nagahisa, Shinya; Hirose, Yuichi

    2014-01-01

    Exogenous fibrin glue (FG) is highly suitable for neurosurgical procedures, because of its viscosity and adhesive properties. Several FGs are commercially available, but only few reports detail their differences. In the present study, we investigated the viscosity and adhesive performance of two types of FG: one is derived from blood donated in Europe and the United States (CSL Behring's Beriplast(®), BP) and the other is derived from blood donated in Japan (the Chemo-Sero-Therapeutic Research Institute's Bolheal(®), BH). The viscosity test that measured fibrinogen viscosity revealed that BP had significantly higher viscosity than BH. Similarly, the dripping test showed that BP traveled a significantly shorter drip distance in the vertical direction than BH, although the transverse diameter of the coagulated FG did not differ statistically significantly. In the tensile strength test, BP showed superior adhesion performance over BH. The histological study of the hematoxylin-eosin-stained specimens in both groups showed favorable adhesion. Although further studies are required on its manufacturing and usage methods, FG shows differences in viscosity and adhesive performance according to the blood from which it is derived. We conclude that it is desirable to select the type and usage method of FG according to the characteristics of the surgical operation in question. Our findings suggest that FG produced from the blood donated in Europe and the United States might be more suitable for use in surgical procedures that demand an especially high degree of viscosity and rapid adhesive performance.

  5. Endoscopic ultrasound-guided coil or glue injection in post-cyanoacrylate gastric variceal re-bleed.

    Science.gov (United States)

    Mukkada, Roy J; Antony, Rajesh; Chooracken, Mathew J; Francis, Jose V; Chettupuzha, Antony P; Mathew, Pradeep G; Augustine, Philip; Koshy, Abraham

    2018-04-09

    N-butyl-cyanoacrylate injection is recommended in bleeding/recently bled gastric varices. However, cyanoacrylate injection is associated with re-bleed in 25% to 50% of patients. Endoscopic ultrasound (EUS)-guided coil application is an emerging treatment modality for bleeding gastric varices. The aim of this study was to compare EUS-guided coil application combined with or without cyanoacrylate glue injection to injection alone in post-glue gastric variceal re-bleed. A retrospective analysis of a prospectively maintained database was performed. Thirty patients who re-bled after cyanoacrylate injection and who had EUS-guided coil application to gastric varices were included. The comparison was done with data of 51 patients who had only repeat cyanoacrylate injection. Both groups had a follow up for 12 months. EUS-guided coil application was done under endosonographic guidance. A single coil was placed in 7, two coils in each of 13 patients, three in 5, four in 3, five in one, and 6 coils in one patient. In addition, cyanoacrylate glue injection was given in 15 patients. Eight patients had repeat EUS-guided coil application 1 month later. Re-bleed and mortality were assessed. Coilng: Six out of 30 (20%) patients re-bled during follow up of 9 to 365 days. Three out of 30 (10%) died. One patient died 9 days after the procedure due to acute respiratory distress syndrome, one died 4 months after the procedure due to a re-bleed and one 5 months after the procedure due to spontaneous bacterial peritonitis. Glue only: 26/51 (51%) re-bled during follow up of 45 to 365 days. EUS-guided coil application resulted in significantly less re-bleed than glue-only (Kaplan-Meir survival analysis with log-rank test, z = 5.4, p guided coil application with/without cyanoacrylate injection for the obliteration of gastric varices is effective for post-cyanoacrylate gastric variceal re-bleed.

  6. Autologous fibrin glue as an encapsulating scaffold for delivery of retinal progenitor cells

    Directory of Open Access Journals (Sweden)

    Tamer Anwar Esmail Ahmed

    2015-02-01

    Full Text Available The retina is a highly sophisticated piece of the neural machinery that begins the translation of incoming light signals into meaningful visual information. Several degenerative diseases of the retina are characterized by photoreceptor loss and eventually lead to irreversible blindness. Regenerative medicine, using tissue engineering-based constructs to deliver progenitor cells or photoreceptors along with supporting carrier matrix is a promising approach for restoration of structure and function. Fresh fibrin glue (FG produced by the CryoSeal®FS system in combination with mouse retinal progenitor cells (RPCs were evaluated in this study. In vitro expanded RPCs isolated from postnatal mouse retina were encapsulated into FG and cultured in the presence of the protease inhibitor, tranexamic acid. Encapsulation of RPCs into FG did not show adverse effects on cell proliferation or cell survival. RPCs exhibited fibroblast-like morphology concomitantly with attachment to the encapsulating FG surface. They expressed α7 and β3 integrin subunits that could mediate attachment to fibrin matrix via an RGD independent mechanism. The three dimensional environment and the attachment surface provided by FG was associated with a rapid downregulation of the progenitor marker SOX2 and enhanced the expression of the differentiation markers CRX and recoverin. However, the in vitro culture conditions did not promote full differentiation into mature photoreceptors. Nevertheless, we have shown that autologous fibrin, when fabricated into a scaffold for RPCs for delivery to the retina, provides the cells with external cues that could potentially improve the differentiation events. Hence, transient encapsulation of RPCs into FG could be a valid and potential treatment strategy to promote retinal regeneration following degenerative diseases. However, further optimization is necessary to maximize the outcomes in terms of mature photoreceptors.

  7. Staple line reinforcement with fleece-coated fibrin glue (TachoComb) after thoracoscopic bullectomy for the treatment of spontaneous pneumothorax

    International Nuclear Information System (INIS)

    Muramatsu, Takashi; Ohmori, Kazumitsu; Shimamura, Mie; Furuichi, Motohiko; Takeshita, Shinji; Negishi, Nanao

    2007-01-01

    We investigated the cause of pneumothorax recurrence after thoracoscopic surgery and the effectiveness of staple line reinforcement with fleece-coated fibrin glue (TachoComb) in the prevention of postoperative pneumothorax recurrence. From April 3, 1992 to the end of December 2005, thoracoscopic bullectomy was performed on 499 patients of primary spontaneous pneumothorax. The causes of recurrence were investigated on 39 patients on the basis of surgical observations, preoperative chest computed tomography, and so on. The most common cause was new bulla formation (37 cases), 19 of which were apparently related to the staple line (within 1 cm of the staple lines) and 15 of which were not related to the staple line. After 2000, we stopped using forceps to grasp lungs and we have reinforced the staple line by applying fleece-coated fibrin glue. The staple line reinforced with fleece-coated fibrin glue, or sprayed with fibrin glue solution and the untreated group (bullectomy only with staples) were compared, and the recurrence rates were 1.22%, 7.25%, and 10.00%, respectively (P=0.0006021). The recurrence rate after thoracoscopic bullectomy with fleece-coated fibrin glue was significantly lowered and we consider this procedure to be the treatment of choice for the management of spontaneous pneumothorax. (author)

  8. Evaluating Uncertainty of Runoff Simulation using SWAT model of the Feilaixia Watershed in China Based on the GLUE Method

    Science.gov (United States)

    Chen, X.; Huang, G.

    2017-12-01

    In recent years, distributed hydrological models have been widely used in storm water management, water resources protection and so on. Therefore, how to evaluate the uncertainty of the model reasonably and efficiently becomes a hot topic today. In this paper, the soil and water assessment tool (SWAT) model is constructed for the study area of China's Feilaixia watershed, and the uncertainty of the runoff simulation is analyzed by GLUE method deeply. Taking the initial parameter range of GLUE method as the research core, the influence of different initial parameter ranges on model uncertainty is studied. In this paper, two sets of parameter ranges are chosen as the object of study, the first one (range 1) is recommended by SWAT-CUP and the second one (range 2) is calibrated by SUFI-2. The results showed that under the same number of simulations (10,000 times), the overall uncertainty obtained by the range 2 is less than the range 1. Specifically, the "behavioral" parameter sets for the range 2 is 10000 and for the range 1 is 4448. In the calibration and the validation, the ratio of P-factor to R-factor for range 1 is 1.387 and 1.391, and for range 2 is 1.405 and 1.462 respectively. In addition, the simulation result of range 2 is better with the NS and R2 slightly higher than range 1. Therefore, it can be concluded that using the parameter range calibrated by SUFI-2 as the initial parameter range for the GLUE is a way to effectively capture and evaluate the simulation uncertainty.

  9. Gas chromatography-mass spectrometry characterization of the varnish and glue of an ancient 18th century double bass.

    Science.gov (United States)

    Caruso, Francesco; Orecchio, Santino; Cicero, Maria Grazia; Di Stefano, Cosimo

    2007-04-20

    A GC-MS investigation is conducted on the double bass "Panormus", property of Conservatorio di Musica "Vincenzo Bellini" in Palermo. The most important components of the varnish (fatty acids) and of the glue (proteinaceous amino acids), with which the musical instrument was treated in the past, are determined. The analyses are carried out by prior derivatization of fatty acids by acidic methanol and of amino acids by acidic methanol and trifluoroacetic anhydride (TFAA). Analytes identification is achieved by direct comparison with several reference materials and the use of a digitized library.

  10. Pancreatic fistula after laparoscopic splenectomy in patients with hypersplenism due to liver cirrhosis: effect of fibrin glue and polyglycolic acid felt on prophylaxis of postoperative complications.

    Science.gov (United States)

    Tsutsumi, Norifumi; Tomikawa, Morimasa; Akahoshi, Tomohiko; Kawanaka, Hirofumi; Ota, Mitsuhiko; Sakaguchi, Yoshihisa; Kusumoto, Tetsuya; Ikejiri, Koji; Hashizume, Makoto; Maehara, Yoshihiko

    2016-11-01

    This study aimed to determine the effect of fibrin glue and polyglycolic acid (PGA) felt on prevention of pancreatic fistula (PF) after laparoscopic splenectomy in patients with hypersplenism due to liver cirrhosis. Fifty consecutive patients were enrolled in this prospective study. Twenty-three patients underwent laparoscopic splenectomy with a fibrin sheet (fibrin sheet group). The sealing ability of each treatment was evaluated by an ex vivo pressure test model. Based on the results from ex vivo experiments, 27 patients received prophylaxis using fibrin glue and PGA felt (PGA with fibrin group). The primary endpoint was the incidence of PF. Significantly more (5, 22%) patients developed PF in the fibrin sheet group than in the PGA with fibrin group (0%, P = .037). Our new application of fibrin glue and PGA felt is an effective prophylactic procedure for preventing development of PF after laparoscopic splenectomy. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. [The advantages in using cyanoacrylate glue over skin staples as a method of skin graft fixation in the pediatric burns population].

    Science.gov (United States)

    Curings, P; Vincent, P-L; Viard, R; Gir, P; Comparin, J-P; Voulliaume, D

    2017-11-23

    Local postoperative care and burn wound management can present with a certain degree of difficulty in the pediatric population. While the use of skin staples as a method of skin graft fixation is a well-known, rapid and simple method, their removal can be painful and may necessitate some sedation or even general anesthesia. We studied in this article the advantages and economic value of using the cyanoacrylate glue as a fixation method for skin grafts. A comparative study was carried out from 2012 to 2016. Hundred and eighteen infants with burns up to 5% of total body surface area were included in the study. Seventy-two infants had split thickness skin grafts fixed with skin staples. Forty-six infants had split thickness skin grafts fixed with cyanoacrylate glue. We compared the quality of graft, the sedation used during the first postoperative dressing, the length of hospital stay, the amount of glue used and the presence of complications. There is a difference between the two groups studied in terms of age and total burn surface area. The rate of graft take was 100% in both groups. The first postoperative dressing was carried out without the use of powerful analgesia in the cyanoacrylate group, while it was necessary to use general anesthesia in 64% of the skin staples group. The average length of stay in hospital after skin grafting was 4.9 days for the cyanoacrylate glue versus 6.5 days in the skin staples group. No complications were noted in the 2 groups. The use of cyanoacrylate glue allows rapid fixation of skin grafts and avoid general anesthesia for postoperative cares. Subsequently the length of hospital stay is reduced within 25%. The medico-economic value of glue protocol is highly significant compared to skin staples, while having similar good results and without significant problems. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  12. Successful management with glue injection of arterial rupture seen during embolization of an arteriovenous malformation using a flow-directed catheter: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Jong Won; Baik, Seung Kug; Shin, Mi Jung; Choi, Han Yong; Kim, Bong Gi [Wallace Memorial Baptist Hospital, Pusan (Korea, Republic of)

    2000-12-01

    We present a case in which an arterial rupture occurring during embolization of an arteriovenous malformation of the left occipital lobe with a flow-directed micro-catheter, was successfully sealed with a small amount of glue. We navigated a 1.8-Fr Magic catheter through the posterior cerebral artery, and during superselective test injection, extravasation was observed at the parieto-occipital branch. The catheter was not removed and the perforation site was successfully sealed with a small amount of glue injected through the same catheter. Prompt recognition and closure of the perforation site is essential for good prognosis. (author)

  13. In search of low cost biological analysis: Wax or acrylic glue bonded paper microfluidic devices

    KAUST Repository

    Kodzius, Rimantas

    2011-01-22

    In this body of work we have been developing and characterizing paper based microfluidic fabrication technologies to produce low cost biological analysis. Specifically we investigated the performance of paper microfluidics that had been bonded using wax or acrylic glue, and characterized the affect of these and other microfluidic materials on the polymerase chain reaction (PCR). We report a simple, low-cost and detachable microfluidic chip incorporating easily accessible paper, glass slides or other polymer films as the chip materials along with adhesive wax or cyanoacrylate-based resin as the recycling bonding material. We use a laser to cut through the paper or film to form patterns and then sandwich the paper and film between glass sheets or polymer membranes. The hot-melt adhesive wax or simple cyanoacrylate-based resin can realize bridge bonding between various materials, for example, paper, polymethylmethacrylate film, glass sheets, or metal plate. The wax bonding process is reversible and the wax is reusable through a melting and cooling process. With this process, a three-dimensional (3D) microfluidic chip is achievable by evacuating the channels of adhesive material in a hot-water. We applied the wax-paper based microfluidic chip to HeLa cell electroporation. Subsequently, a prototype of a 5-layer 3D chip was fabricated by multilayer wax bonding. To check the sealing ability and the durability of the chip, green fluorescence protein recombinant E. coli bacteria were cultured, with which the chemotaxis of E. coli was studied in order to determine the influence of antibiotic ciprofloxacin concentration on the E. coli migration. The chip bonded with cyanoacrylate-based resin was tested by measuring protein concentration and carrying out DNA capillary electrophoresis. To study the biocompatibility and applicability of our microfluidic chip fabrication technology, we tested the PCR compatibility of our chip materials along with various other common materials

  14. Effects of diode laser welding with dye-enhanced glue on tensile strength of sutures commonly used in urology.

    Science.gov (United States)

    Kirsch, A J; Chang, D T; Kayton, M L; Libutti, S K; Connor, J P; Hensle, T W

    1996-01-01

    Tissue welding using laser-activated protein solders may soon become an alternative to sutured tissue approximation. In most cases, approximating sutures are used both to align tissue edges and provide added tensile strength. Collateral thermal injury, however, may cause disruption of tissue alignment and weaken the tensile strength of sutures. The objective of this study was to evaluate the effect of laser welding on the tensile strength of suture materials used in urologic surgery. Eleven types of sutures were exposed to diode laser energy (power density = 15.9 W/cm2) for 10, 30, and 60 seconds. Each suture was compared with and without the addition of dye-enhanced albumin-based solder. After exposure, each suture material was strained (2"/min) until ultimate breakage on a tensometer and compared to untreated sutures using ANOVA. The strength of undyed sutures were not significantly affected; however, violet and green-dyed sutures were in general weakened by laser exposure in the presence of dye-enhanced glue. Laser activation of the smallest caliber, dyed sutures (7-0) in the presence of glue caused the most significant loss of tensile strength of all sutures tested. These results indicate that the thermal effects of laser welding using our technique decrease the tensile strength of dyed sutures. A thermally resistant suture material (undyed or clear) may prevent disruption of wounds closed by laser welding techniques.

  15. Treatment for intractable anemia with the traditional Chinese medicines Hominis Placenta and Cervi Cornus Colla (deer antler glue

    Directory of Open Access Journals (Sweden)

    Yasuyo Hijikata

    2009-05-01

    Full Text Available Yasuyo Hijikata1, Takashi Kano2, Lu Xi31Toyodo Hijikata Clinic, Osaka, Japan; 2Kano Clinic, Osaka city, Osaka, Japan; 3Traditional Chinese Medicine Institute, Si-chuan Province, ChinaObjective: Intractable anemia, such as aplastic anemia or that presumably associated with chronic herpes virus infections, sometimes require bone marrow transplant. We investigated the use of traditional Chinese medicine (TCM for the treatment of intractable anemia. Method: Placenta Hominis (PH, steam boiled and roasted, and Cervi Cornus Colla (deer antler glue has been used in China for hundreds of years to treat anemia. After consent was obtained, we prescribed these two materials for a 74-year-old female with aplastic anemia and a 26-year-old male with presumably a virus-induced anemia. Concomitant conventional therapy was continued in both patients as prescribed by their respective attending physicians. Conclusion: Conventional therapy with steroid hormones, immunosuppressive drugs, platelet and erythrocyte transfusions were not effective in these patients. In addition, both patients suffered from serious side effects. In two patients, ingestion of Placenta Hominis and Cervi Cornus Colla with TCM prescriptions increased the platelet and enhanced the hemoglobin concentration in several months of therapy accompanied by a dramatic improvement in quality of life. The addition to conventional therapy of PH and Cervi Cornus Colla, the latter of which is very easy to obtain, may be one of the potentially advantageous choices in case of otherwise intractable anemia.Keywords: placenta, antler glue, Cervi Cornus Colla, anemia, aplastic anemia

  16. Boll weevil within season and off-season activity monitored using a pheromone-and-glue reusable tube trap

    Directory of Open Access Journals (Sweden)

    Robério Carlos dos Santos Neves

    Full Text Available ABSTRACT: The boll weevil colonizes cotton fields as early as cotton squaring, causing significant losses due to feeding and protected development inside fruiting structures throughout crop phenology. Successful control depends on control of adults and their accurate detection when they colonize the crops. The commercial trap and boll weevil attract-and-control tubes (BWACT are the only available tools to monitor and attract-and-kill boll weevil, despite limitation in efficacy, and insecticide in BWACT is not allowed in organic production. A grandlure-and-glue reusable and insecticide-free tube (GGT made with polyvinyl chloride tube, smeared with entomological glue, and lured with pheromone was tested to detect boll weevil activity across various seasons. Boll weevil showed activity during growing season and off-season from 2009 to 2012 in the Semiarid and with higher numbers captured in GGT in comparisons to commercial traps. GGT was able to detect early weevils in the field right after planting. Further, the overall averages resulted in 34-, 16.8-, and 7.5-times more weevils captured in GGTs compared to the traps during stalk destruction in the Semiarid 2011 and Cerrado season 2012/13 and during the harvesting period in the Cerrado season 2011/12, respectively. Therefore, boll weevils were captured actively during season and off-season and early captures obtained in GGT compared to traps showed a better correlation between captures and square damage.

  17. Informal uncertainty analysis (GLUE) of continuous flow simulation in a hybrid sewer system with infiltration inflow - Consistency of containment ratios in calibration and validation?

    DEFF Research Database (Denmark)

    Breinholt, Anders; Grum, Morten; Madsen, Henrik

    2013-01-01

    to assess parameter and flow simulation uncertainty using a simplified lumped sewer model that accounts for three separate flow contributions: wastewater, fast runoff from paved areas, and slow infiltrating water from permeable areas. Recently GLUE methodology has been critisised for generating prediction...... rain inputs and more accurate flow observations to reduce parameter and model simulation uncertainty. © Author(s) 2013....

  18. Re: Fibrin Glue Injections: A Minimally Invasive and Cost-Effective Treatment for Post-Renal Transplant Lymphoceles and Lymph Fistulas

    Directory of Open Access Journals (Sweden)

    Presser N

    2016-03-01

    Full Text Available In this retrospective study, 46 (2.7% patients out of 1662 kidney transplant recipients had developed symptomatic lymphocele/lymph fistula requiring intervention over an 11-year period. Open surgical drainage (22, laparoscopic surgical drainage (11 and percutaneous fibrin glue injections into the drained lymphocele cavity (13 were used to treat this complication. Besides being effective both on the early and late developed lymphoceles, significantly lower recurrence rates by fibrin glue injections and lower median treatment costs were observed when compared with the other two surgical modalities. It has also the advantage of an outpatient procedure that can be performed using fluoroscopic guidance, under local anesthesia. However, due to era effect, most of the open and laparoscopic surgical recipients were treated with sirolimus, a well-known antiproliferative immunosuppressive agent, which can promote development of lymphoceles and surgical failure. However, the majority of fibrin glue-treated cases were with tacrolimus-based regimens, but this study, in its nature, is far from giving the answer for decreased number of recurrences with fibrin glue

  19. Improved distal distribution of n-butyl cyanoacrylate glue by simultaneous injection of dextrose 5% through the guiding catheter: technical note

    International Nuclear Information System (INIS)

    Moore, Carolyn; Murphy, Kieran; Gailloud, Philippe

    2006-01-01

    The use of n-butyl cyanoacrylate (NBCA) as an adhesive agent for embolization of high-flow intracranial and extracranial vascular lesions is well established. To be successful, the embolization of arteriovenous malformations and fistulas must achieve obliteration of the arteriovenous shunts themselves rather than simply occlude the feeders proximal to the lesion. However, the feeders cannot always be negotiated over their entire length. This is often the case with dural arteriovenous fistulas (DAVF), which are usually vascularized by long and intricate meningeal networks. In such situations, NBCA may not be able to reach the lesion itself, rendering the embolization ineffective. We present a new technique that improves distal distribution of NBCA glue. The technique described in this report consists of injecting dextrose 5% through the guiding catheter simultaneously with the superselective injection of NBCA glue into the targeted feeding branch. The technique is illustrated with three cases of posterior fossa DAVF. In the reported cases, flooding the territory of the targeted vessel with non-ionic dextrose 5% allowed deep progression of the glue by delaying contact with ionic substances. Excellent distribution of the NBCA glue reaching the site of the arteriovenous shunts was thus obtained despite suboptimal proximal microcatheter tip positions. (orig.)

  20. Alternative glues for the production of ATLAS silicon strip modules for the Phase-II upgrade of the ATLAS Inner Detector

    CERN Document Server

    INSPIRE-00407830; Bloch, Ingo; Edwards, Sam; Friedrich, Conrad; Gregor, Ingrid M.; Jones, T; Lacker, Heiko; Pyatt, Simon; Rehnisch, Laura; Sperlich, Dennis; Wilson, John

    2016-05-24

    The Phase-II upgrade of the ATLAS detector for the High Luminosity Large Hadron Collider (HL-LHC) includes the replacement of the current Inner Detector with an all-silicon tracker consisting of pixel and strip detectors. The current Phase-II detector layout requires the construction of 20,000 strip detector modules consisting of sensor, circuit boards and readout chips, which are connected mechanically using adhesives. The adhesive between readout chips and circuit board is a silver epoxy glue as was used in the current ATLAS SemiConductor Tracker (SCT). This glue has several disadvantages, which motivated the search for an alternative. This paper presents a study concerning the use of six ultra-violet (UV) cure glues and a glue pad for use in the assembly of silicon strip detector modules for the ATLAS upgrade. Trials were carried out to determine the ease of use, the thermal conduction and shear strength, thermal cycling, radiation hardness, corrosion resistance and shear strength tests. These investigatio...

  1. Analysis of stress- strain distribution of dowel and glue line in L-type furniture joint by means of finite element method

    Directory of Open Access Journals (Sweden)

    mossayeb dalvand

    2017-08-01

    Full Text Available In this study 3D stress-strain distribution of dowel and glue line on L-type joints made of plywood doweled was investigated. Members of joints made of 11-ply hardwood plywood (Hornbeam, Beech and Alder that were 19 mm in thickness. In this study effect of beech dowels in three levels diameters (6, 8 and 10 mm and penetration of depth (9, 13 and 17 mm on bending moment capacity of L-type joints under compression loading was investigated as experimental test, then stress-strain distribution of wood dowel and glue line in specimens were simulated by means of ANSYS 15 software with finite element method (FEM.Results have shown that bending moment resistance increased with increasing dowel diameter from 6 to 8 mm, but downward trend was observed with increasing 8 to 10 mm in dowel diameter. Bending moment resistance increased with increasing penetration depth. Also, result obtained of simulation by means of ANSYS software have shown that stress-strain in dowel and glue line increased with increasing diameter of dowel and Increasing stress in joints made of diameter dowel 10 mm due to fracture in joints and decrease in resistance once. According to results obtained of model analysis, the ultimate stress of dowel and glue line occurred in the area that joints were contacted.

  2. Use of fibrin glue derived from snake venom in the repair of deep corneal ulcers: experimental study in dogs (Canis familiaris, Linnaeus, 1758

    Directory of Open Access Journals (Sweden)

    R. L. Sampaio

    2007-01-01

    Full Text Available Fibrin glue has been researched as an alternative method for tissue synthesis and is known for its capability to promote hemostasis at the application site, good approximation of wound edges and fast healing. The current study consisted in the application of fibrin glue derived from snake venom as treatment for experimental corneal ulcers. Twenty-one dogs had their corneas experimentally prepared through lamellar keratectomy (of standardized diameter and depth. Animals were divided into seven groups of three animals each. Six experimental groups were periodically evaluated and collection was carried out on the 1st, 3rd, 7th, 15th, 30th and 60th post-operative days, whereas one control group was evaluated throughout the experiment. Analyses consisted in the clinical evolution and in the histopathological study of all operated on eyes. Results indicated that fibrin glue was efficient in repairing keratectomy wounds in dogs and contributed to an earlier healing phenomenon, avoiding edema formation and keeping corneal clearness. The use of fibrin glue derived from snake venom showed to be easy to apply, feasible with animal models and of low cost, avoiding the lesion progress and allowing fast and appropriate corneal healing.

  3. Management of an extrasphincteric fistula in an HIV-positive patient by using fibrin glue: a case report with tips and tricks

    Directory of Open Access Journals (Sweden)

    Sapalidis Konstantinos

    2010-02-01

    Full Text Available Abstract Background Individuals with impaired immunity are at higher risk of perianal diseases. Concerning complex anal fistulas impaired healing and complication rates are also higher. Definitive treatment of a fistula aims controlling the purulent discharge and prevents its recurrence. It depends mainly on the trajectory of the fistula and the underlying disease. We present a case of a HIV-positive patient with a complex extrasphincteric anal fistula who was treated successfully with fibrin glue application. We further, discuss tips and tricks when applying fibrin glue as plugging material in complex anal fistulas. Case presentation A sixty-one-year-old HIV-positive male referred to us for warts and extrasphincteric fistula. Because of the patients' immunological status, we opted against surgery and recommended fibrin glue plugging. The patient was discharged the same day. A follow-up examination was performed 5 days after the initial fibrin glue application showing that the fistula canal was obstructed. Three months and a year post-intervention the fistula tract remains closed. Conclusion The best treatment for a disease gives at least the same result with the other treatments with minimised risk for the life of the patient and minimal application effort. Conservative closure of fistula with fibrin plugging is simple, safe and with less morbidity than surgery. Our patient was successfully treated without endangering his life despite his precarious medical state. Not everybody believes in the effectiveness of fibrin glue application, however we consider this solution in cases of complex fistulas at least as primary procedure in special populations such as the immunosupressed.

  4. Encephalopathy and Neuropathy due to Glue, Paint Thinner, and Gasoline Sniffing in Trinidad and Tobago-MRI Findings

    Directory of Open Access Journals (Sweden)

    Kanterpersad Ramcharan

    2014-01-01

    Full Text Available A 29-year-old male petrol station pump attendant was admitted with ataxia and clinical evidence of a sensorimotor polyneuropathy which developed over the preceding 3 months. He had cognitive dysfunction, hearing loss, and cerebellar clinical abnormalities that came on slowly over the three years. He had a fifteen-year history of sniffing mostly glue, occasionally paint thinners, and, in the recent two years, gasoline. Magnetic resonance brain imaging showed abnormalities of the cerebral cortex, cerebral white matter, corpus callosum, hippocampus, brainstem and cerebellar atrophy, hypointensities of basal ganglia, red nuclei, and substantia nigra as previously described in toluene sniffing. Abstinence for six months led to partial clinical improvement. Clinicians need to be aware of this preventable entity which has peculiar radiological findings which are being increasingly accepted as typical.

  5. First e⁻/γ Commissioning Results for the GlueX Experiment/Hall D at CEBAF

    Energy Technology Data Exchange (ETDEWEB)

    McCaughan, Michael D. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Satogata, Todd J. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Roblin, Yves R. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Benesch, Jay F. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States)

    2015-09-01

    Experimental Hall D, with flagship experiment GlueX, was constructed as part of the 12 GeV CEBAF upgrade. A new magnetically extracted electron beam line was installed to support this hall. Bremsstrahlung photons from retractable radiators are delivered to the experiment through a series of collimators following a long drift to allow for beam convergence. Coherent Bremsstrahlung generated by interaction with a diamond radiator will achieve a nominal 40% linear polarization and photon energies between 8.5 and 9 GeV from 12.1 GeV electrons, which are then tagged or diverted to a medium power 60kW electron dump. The expected photon flux is 107-108 Hz. This paper discusses the experimental line design, commissioning experience gained since first beam in spring 2014, and the present results of beam commissioning by the experiment.

  6. Fabrication of ceramic oxide-coated SWNT composites by sol-gel process with a polymer glue

    Science.gov (United States)

    Zhang, Cheng; Gao, Lei; Chen, Yongming

    2011-09-01

    The functional copolymer bearing alkoxysilyl and pyrene groups, poly[3-(triethoxysilyl)propyl methacrylate]- co-[(1-pyrene-methyl) methacrylate] (TEPM13- co-PyMMA3), was synthesized via atom transfer radical polymerization. Attributing the π-π interaction of pyrene units with the walls of single-walled carbon nanotubes (SWNTs), this polymer could disperse and exfoliate SWNTs in different solvents through physical interaction as demonstrated by TEM, UV/Vis absorption, and FT-IR analysis. The alkoxysilyl groups functionalized SWNTs were reacted with different inorganic precursors via sol-gel reaction, and, as a results, silica, titania, and alumina were coated onto the surface of SWNTs, respectively via copolymers as a molecular glue. The nanocomposites of ceramic oxides/SWNTs were characterized by SEM analysis. Dependent upon the feed, the thickness of inorganic coating can be tuned easily. This study supplies a facile and general way to coat SWNTs with ceramic oxides without deteriorating the properties of pristine SWNTs.

  7. Nd:YAG laser double wavelength ablation of pollution encrustation on marble and bonding glues on duplicated painting canvas

    Science.gov (United States)

    Batishche, Sergei; Englezis, Apostolis; Gorovets, Tatiana; Kouzmouk, Andrei; Pilipenka, Uladzimir; Pouli, Paraskevi; Tatur, Hennady; Totou, Garyfallia; Ukhau, Viktar

    2005-07-01

    In the present study, a newly developed one-beam IR-UV laser cleaning system is presented. This system may be used for different applications in diverse fields, such as outdoors stonework conservation and canvas paintings restoration. The simultaneous use of the fundamental radiation of a Q-switched Nd:YAG laser at 1064 nm and its third harmonic at 355 nm was found appropriate to clean pollution crusts, while ensuring that no discoloration ("yellowing") would occur. The optimum ratio of UV to IR wavelengths in the final cleaning beam was investigated. In parallel, the same system was tested in diverse applications, such as the removal of bonding glues from duplicated canvases. The optimum laser parameters were investigated both on technical samples as well as on original paintings.

  8. A new platelet cryoprecipitate glue promoting bone formation after ectopic mesenchymal stromal cell-loaded biomaterial implantation in nude mice.

    Science.gov (United States)

    Trouillas, Marina; Prat, Marie; Doucet, Christelle; Ernou, Isabelle; Laplace-Builhé, Corinne; Blancard, Patrick Saint; Holy, Xavier; Lataillade, Jean-Jacques

    2013-01-04

    This study investigated the promising effect of a new Platelet Glue obtained from Cryoprecipitation of Apheresis Platelet products (PGCAP) used in combination with Mesenchymal Stromal Cells (MSC) loaded on ceramic biomaterials to provide novel strategies enhancing bone repair. PGCAP growth factor content was analyzed by ELISA and compared to other platelet and plasma-derived products. MSC loaded on biomaterials (65% hydroxyapatite/35% beta-TCP or 100% beta-TCP) were embedded in PGCAP and grown in presence or not of osteogenic induction medium for 21 days. Biomaterials were then implanted subcutaneously in immunodeficient mice for 28 days. Effect of PGCAP on MSC was evaluated in vitro by proliferation and osteoblastic gene expression analysis and in vivo by histology and immunohistochemistry. We showed that PGCAP, compared to other platelet-derived products, allowed concentrating large amount of growth factors and cytokines which promoted MSC and osteoprogenitor proliferation. Next, we found that PGCAP improves the proliferation of MSC and osteogenic-induced MSC. Furthermore, we demonstrated that PGCAP up-regulates the mRNA expression of osteogenic markers (Collagen type I, Osteonectin, Osteopontin and Runx2). In vivo, type I collagen expressed in ectopic bone-like tissue was highly enhanced in biomaterials embedded in PGCAP in the absence of osteogenic pre-induction. Better results were obtained with 65% hydroxyapatite/35% beta-TCP biomaterials as compared to 100% beta-TCP. We have demonstrated that PGCAP is able to enhance in vitro MSC proliferation, osteoblastic differentiation and in vivo bone formation in the absence of osteogenic pre-induction. This clinically adaptable platelet glue could be of interest for improving bone repair.

  9. Design and Fabrication of Calibration Device for Scintillating Fibers of Tagger Microscope: For use in GlueX's QCD Experiment

    Science.gov (United States)

    Briere, Emily

    2012-10-01

    For decades, scientists have struggled to understand the chromo-electromagnetic field which confines quarks and gluons within the hadron. GlueX is a QCD experiment centered at Jefferson Lab, Virginia, seeking to better understand this gluonic field by exciting it and mapping the spectrum of exotic hybrid mesons that it generates. The experiment uses coherent bremsstrahlung radiation to produce a beam of photons, which due to their polarity act as virtual vector mesons. When incident on a liquid hydrogen target, these mesons are expected to form exotic hybrid mesons. Such particles quickly decay into new particles which are captured in a solenoid detector. The decays can then be reconstructed to examine the properties of the original exotic hybrid meson, although the initial energy of the photon is required to draw meaningful conclusions. The post-bremsstrahlung degraded electrons are bent from the main beam into the tagger microscope where they strike an array of scintillating optical fibers. Given the correlation between momentum and radial bend, the Silicon Photmultiplier sensors attached to the optical fibers are able to ``tag'' the electrons', and thus the photons', initial energies based on which fibers were hit. Providing central data for GlueX, the tagger microscope must be accurate. This paper details the design and fabrication of a scintillating fiber calibration device that moves horizontally above fiber bundles, using a green laser diode to direct light pulses into the fibers. This calibration method has been tested mechanically and via a Monte Carlo Matlab simulation, and has proven to be effective.

  10. Management of a complicated pulmonary fistula caused by lung cancer using a fibrin glue-soaked polyglycolic acid sheet covered with an intercostal muscle flap.

    Science.gov (United States)

    Maniwa, Tomohiro; Kaneda, Hiroyuki; Saito, Yukihito

    2009-06-01

    Pulmonary fistulas caused by tumours are very fragile and difficult to suture directly. It is impossible to close pulmonary fistulas with tissue sealants when massive air leakage occurs in the low pressure of the respiratory tract. A 73-year-old man with a pneumothorax caused by lung cancer had suffered a persistent massive air leakage for more than one month. We used a fibrin glue-soaked polyglycolic acid (PGA) sheet for sealing the complicated fistula. In addition, the visceral pleura of the fistula was wrapped with the pedicle of an intercostal muscle (ICM) flap to prevent massive air leakage. The pneumothorax did not reappear after surgery. Thus, a fibrin glue-soaked PGA sheet covered with an ICM flap was effective for sealing an intractable air-leaking fistula caused by lung cancer.

  11. Determining the hydraulic and fracture properties of the Coal Seam Gas well by numerical modelling and GLUE analysis

    Science.gov (United States)

    Askarimarnani, Sara; Willgoose, Garry; Fityus, Stephen

    2017-04-01

    Coal seam gas (CSG) is a form of natural gas that occurs in some coal seams. Coal seams have natural fractures with dual-porosity systems and low permeability. In the CSG industry, hydraulic fracturing is applied to increase the permeability and extract the gas more efficiently from the coal seam. The industry claims that it can design fracking patterns. Whether this is true or not, the public (and regulators) requires assurance that once a well has been fracked that the fracking has occurred according to plan and that the fracked well is safe. Thus defensible post-fracking testing methodologies for gas generating wells are required. In 2009 a fracked well HB02, owned by AGL, near Broke, NSW, Australia was subjected to "traditional" water pump-testing as part of this assurance process. Interpretation with well Type Curves and simple single phase (i.e. only water, no gas) highlighted deficiencies in traditional water well approaches with a systemic deviation from the qualitative characteristic of well drawdown curves (e.g. concavity versus convexity of drawdown with time). Accordingly a multiphase (i.e. water and methane) model of the well was developed and compared with the observed data. This paper will discuss the results of this multiphase testing using the TOUGH2 model and its EOS7C constitutive model. A key objective was to test a methodology, based on GLUE monte-carlo calibration technique, to calibrate the characteristics of the frack using the well test drawdown curve. GLUE involves a sensitivity analysis of how changes in the fracture properties change the well hydraulics through and analysis of the drawdown curve and changes in the cone of depression. This was undertaken by changing the native coal, fracture, and gas parameters to see how changing those parameters changed the match between simulations and the observed well drawdown. Results from the GLUE analysis show how much information is contained in the well drawdown curve for estimating field scale

  12. Autologous plasma rich in growth factors in the prevention of severe bleeding after teeth extractions in patients with bleeding disorders: a controlled comparison with fibrin glue

    Science.gov (United States)

    Cocero, Nadia; Pucci, Fabrizio; Messina, Maria; Pollio, Berardino; Mozzati, Marco; Bergamasco, Laura

    2015-01-01

    Background Dental extractions in haemophiliacs may cause secondary bleeding, requiring repeated surgical and haematological interventions. As a local haemostatic, fibrin glue has recognised efficacy but, as a plasma-derived product, it carries the risk of viral infections. We, therefore, compared fibrin glue with an autologous haemostatic, plasma rich in growth factors (PRGF), in a controlled trial. Material and methods One hundred and twenty patients with different blood disorders were randomised into two cohorts to undergo dental extraction procedures without hospitalisation. Prior to the extractions, patients underwent systemic haematological treatment. Complications were defined as secondary bleeding after the 7-day follow-up period or protracting after the repair procedure. Results There were 106 extractions (7 retained 3rd molars) in the group managed with fibrin glue: secondary bleeding affected 3/60 patients (5%) on the third day after extraction and necessitated additional surgery and systemic treatment (in one case the procedure had to be repeated on the 7th day). In the PRGF arm there were 98 extractions (23 retained 3rd molars): secondary bleeding affected two patients (3.3%) on the first day after extraction and was arrested with surgery without systemic treatment. Four out of the five secondary bleeds occurred in patients with haemophilia A. Concomitant diabetes or liver disease significantly increased the bleeding risk. Discussion The bleeding rates in the study and control arm prove that PRGF works as well as fibrin glue as a local haemostatic. Further assets are that PRGF has autologous origin, does not require additional systemic treatment in post-extraction repair surgery, is associated with an earlier onset of neo-angiogenesis and, overall, can reduce patients’ distress and costs to the health system. PMID:25369587

  13. [Research of repairing rabbit knee joint cartilage defect by compound material of fibrin glue and decalcified bone matrix (DBM) and chondrocytes].

    Science.gov (United States)

    He, Jie; Yang, Xiang; Yue, Peng-ju; Wang, Guan-yu; Guo, Ting; Zhao, Jian-ning

    2009-07-01

    To investigate the feasibility and effectivity of using compound material of fibrin glue and DBM as scaffolds for cartilage tissue engineering. Chondrocytes isolated from articular cartilage were seeded into prepared scaffolds, after incubation for 4 weeks in vitro. Chondrocytes and fibrin glue and DBM constructs were implanted in the joint cave of rabbit. The specimens were excised at the 4th, 8th, 12th week, examined grossly analyzed by haematoxylin cosine, toluidine blues staining and type II collagen immunohistochemistry reaction. Wakitani score was counted to evaluate the repairing effect. Grossly analysis showed some ivory tissue filled the caves after 4 weeks and the caves were full filled with smooth surface after 12 weeks. The microscope showed a good deal of chondrocytes appeared after 8 weeks and more type II collagen than 4 weeks. Twelve weeks later, cartilage lacuna could be observed. The cells arrangement and the amount of type II collagen both showed the same as the natural one. Complicated material of fibrin glue and DBM as scaffolds can be used as scaffolds for cartilage tissue engineering.

  14. Geometry effect on the behaviour of single and glue-laminated glass fibre reinforced polymer composite sandwich beams loaded in four-point bending

    International Nuclear Information System (INIS)

    Awad, Ziad K.; Aravinthan, Thiru; Manalo, Allan

    2012-01-01

    Highlights: ► Investigated the behaviour of single and glue-laminated GFRP sandwich beam. ► Effect of shear span to depth was a key factor affecting the overall behaviour. ► Comparison with prediction models gave reasonable results in specific regions. ► A failure map was developed to identify the shear and flexural failures of panels. -- Abstract: The research investigated the behaviour of single and glue laminated glass fibre reinforced polymer (GFRP) composite sandwich beams considering different spans and beam cross sections. The composite sandwich beams with different thicknesses (1, 2, 3, 4, and 5 sandwich layers) have been tested in four-point static flexural test with different shear span to depth ratio (a/d). The a/d ratios showed a direct effect on the flexural and shear behaviour. The capacity of the beam decreased with increasing a/d. Various failure modes were observed including core crushing, core shear, and top skin compression failure. The failure mode map developed based on the experimental finding and analytical prediction indicated that the failure mode is affected by the a/d with the number of glue laminated panels.

  15. Fabrication of ceramic oxide-coated SWNT composites by sol–gel process with a polymer glue

    International Nuclear Information System (INIS)

    Zhang Cheng; Gao Lei; Chen Yongming

    2011-01-01

    The functional copolymer bearing alkoxysilyl and pyrene groups, poly[3-(triethoxysilyl)propyl methacrylate]-co-[(1-pyrene-methyl) methacrylate] (TEPM 13 -co-PyMMA 3 ), was synthesized via atom transfer radical polymerization. Attributing the π–π interaction of pyrene units with the walls of single-walled carbon nanotubes (SWNTs), this polymer could disperse and exfoliate SWNTs in different solvents through physical interaction as demonstrated by TEM, UV/Vis absorption, and FT-IR analysis. The alkoxysilyl groups functionalized SWNTs were reacted with different inorganic precursors via sol–gel reaction, and, as a results, silica, titania, and alumina were coated onto the surface of SWNTs, respectively via copolymers as a molecular glue. The nanocomposites of ceramic oxides/SWNTs were characterized by SEM analysis. Dependent upon the feed, the thickness of inorganic coating can be tuned easily. This study supplies a facile and general way to coat SWNTs with ceramic oxides without deteriorating the properties of pristine SWNTs.

  16. EFFECTS OF PRESS PRESSURE ON GLUE LINE THICKNESS AND PROPERTIES OF LAMINATED VENEER LUMBER GLUED WITH MELAMINE UREA FORMALDEHYDE ADHESIVE

    Directory of Open Access Journals (Sweden)

    Ramazan Kurt,

    2012-07-01

    Full Text Available Laminated veneer lumbers (LVLs were manufactured from half-round sliced I-214 hybrid poplar clone veneers with MUF adhesives using press pressures ranging from 2.5 to 15 kg cm-2. The results showed that the press pressures affected the glue line thickness (GLT and the physical and mechanical properties of the LVLs. Higher specific gravity (SG and mechanical properties, but lower GLT were developed as a result of using higher press pressures. The optimum press pressure was found to be 10 kg cm-2 in relation to GLT, SG, and mechanical properties. Significant linear correlations were found between GLT and mechanical properties. GLT can be used to determine the quality of wood bonding and may become a valuable tool for this purpose. Reliable data on the optimum GLT and press pressures can be used to design safe wood bonding applications in all aspects of wood based composites, as well as wood constructions when appropriate techniques are adopted to measure the GLT.

  17. Efficacy of multifunnel traps for capturing emerald ash borer (Coleoptera: Buprestidae): effect of color, glue, and other trap coatings.

    Science.gov (United States)

    Francese, Joseph A; Fraser, Ivich; Lance, David R; Mastro, Victor C

    2011-06-01

    Tens of thousands of adhesive-coated purple prism traps are deployed annually in the United States to survey for the invasive emerald ash borer, Agrilus planipennis Fairmaire (Coleoptera: Buprestidae). A reusable, more user-friendly trap is desired by program managers, surveyors, and researchers. Field assays were conducted in southeastern Michigan to ascertain the feasibility of using nonsticky traps as survey and detection tools for emerald ash borer. Three nonsticky trap designs, including multifunnel (Lindgren), modified intercept panel, and drainpipe (all painted purple) were compared with the standard purple prism trap; no statistical differences in capture of emerald ash borer adults were detected between the multifunnel design and the prism. In subsequent color comparison assays, both green- and purple-painted multifunnel traps (and later, plastic versions of these colors) performed as well or better than the prism traps. Multifunnel traps coated with spray-on adhesive caught more beetles than untreated traps. The increased catch, however, occurred in the traps' collection cups and not on the trap surface. In a separate assay, there was no significant difference detected between glue-coated traps and Rain-X (normally a glass treatment)-coated traps, but both caught significantly more A. planipennis adults than untreated traps.

  18. Glue protein production can be triggered by steroid hormone signaling independent of the developmental program in Drosophila melanogaster.

    Science.gov (United States)

    Kaieda, Yuya; Masuda, Ryota; Nishida, Ritsuo; Shimell, MaryJane; O'Connor, Michael B; Ono, Hajime

    2017-10-01

    Steroid hormones regulate life stage transitions, allowing animals to appropriately follow a developmental timeline. During insect development, the steroid hormone ecdysone is synthesized and released in a regulated manner by the prothoracic gland (PG) and then hydroxylated to the active molting hormone, 20-hydroxyecdysone (20E), in peripheral tissues. We manipulated ecdysteroid titers, through temporally controlled over-expression of the ecdysteroid-inactivating enzyme, CYP18A1, in the PG using the GeneSwitch-GAL4 system in the fruit fly Drosophila melanogaster. We monitored expression of a 20E-inducible glue protein gene, Salivary gland secretion 3 (Sgs3), using a Sgs3:GFP fusion transgene. In wild type larvae, Sgs3-GFP expression is activated at the midpoint of the third larval instar stage in response to the rising endogenous level of 20E. By first knocking down endogenous 20E levels during larval development and then feeding 20E to these larvae at various stages, we found that Sgs3-GFP expression could be triggered at an inappropriate developmental stage after a certain time lag. This stage-precocious activation of Sgs3 required expression of the Broad-complex, similar to normal Sgs3 developmental regulation, and a small level of nutritional input. We suggest that these studies provide evidence for a tissue-autonomic regulatory system for a metamorphic event independent from the primary 20E driven developmental progression. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Informal uncertainty analysis (GLUE of continuous flow simulation in a hybrid sewer system with infiltration inflow – consistency of containment ratios in calibration and validation?

    Directory of Open Access Journals (Sweden)

    A. Breinholt

    2013-10-01

    Full Text Available Monitoring of flows in sewer systems is increasingly applied to calibrate urban drainage models used for long-term simulation. However, most often models are calibrated without considering the uncertainties. The generalized likelihood uncertainty estimation (GLUE methodology is here applied to assess parameter and flow simulation uncertainty using a simplified lumped sewer model that accounts for three separate flow contributions: wastewater, fast runoff from paved areas, and slow infiltrating water from permeable areas. Recently GLUE methodology has been critisised for generating prediction limits without statistical coherence and consistency and for the subjectivity in the choice of a threshold value to distinguish "behavioural" from "non-behavioural" parameter sets. In this paper we examine how well the GLUE methodology performs when the behavioural parameter sets deduced from a calibration period are applied to generate prediction bounds in validation periods. By retaining an increasing number of parameter sets we aim at obtaining consistency between the GLUE generated 90% prediction limits and the actual containment ratio (CR in calibration. Due to the large uncertainties related to spatio-temporal rain variability during heavy convective rain events, flow measurement errors, possible model deficiencies as well as epistemic uncertainties, it was not possible to obtain an overall CR of more than 80%. However, the GLUE generated prediction limits still proved rather consistent, since the overall CRs obtained in calibration corresponded well with the overall CRs obtained in validation periods for all proportions of retained parameter sets evaluated. When focusing on wet and dry weather periods separately, some inconsistencies were however found between calibration and validation and we address here some of the reasons why we should not expect the coverage of the prediction limits to be identical in calibration and validation periods in real

  20. Mesh fixation in laparoscopic incisional hernia repair: glue fixation provides attachment strength similar to absorbable tacks but differs substantially in different meshes.

    Science.gov (United States)

    Rieder, Erwin; Stoiber, Martin; Scheikl, Verena; Poglitsch, Marcus; Dal Borgo, Andrea; Prager, Gerhard; Schima, Heinrich

    2011-01-01

    Laparoscopic ventral hernia repair has gained popularity among minimally invasive surgeons. However, mesh fixation remains a matter of discussion. This study was designed to compare noninvasive fibrin-glue attachment with tack fixation of meshes developed primarily for intra-abdominal use. It was hypothesized that particular mesh structures would substantially influence detachment force. For initial evaluation, specimens of laminated polypropylene/polydioxanone meshes were anchored to porcine abdominal walls by either helical titanium tacks or absorbable tacks in vitro. A universal tensile-testing machine was used to measure tangential detachment forces (TF). For subsequent experiments of glue fixation, polypropylene/polydioxanone mesh and 4 additional meshes with diverse particular mesh structure, ie, polyvinylidene fluoride/polypropylene mesh, a titanium-coated polypropylene mesh, a polyester mesh bonded with a resorbable collagen, and a macroporous condensed PTFE mesh were evaluated. TF tests revealed that fibrin-glue attachment was not substantially different from that achieved with absorbable tacks (median TF 7.8 Newton [N], range 1.3 to 15.8 N), but only when certain open porous meshes (polyvinylidene fluoride/polypropylene mesh: median 6.2 N, range 3.4 to 10.3 N; titanium-coated polypropylene mesh: median 5.2 N, range 2.1 to 11.7 N) were used. Meshes coated by an anti-adhesive barrier (polypropylene/polydioxanone mesh: median 3.1 N, range 1.7 to 5.8 N; polyester mesh bonded with a resorbable collagen: median 1.3 N, range 0.5 to 1.9 N), or the condensed PTFE mesh (median 3.1 N, range 2.1 to 7.0 N) provided a significantly lower TF (p < 0.01). Fibrin glue appears to be an appealing noninvasive option for mesh fixation in laparoscopic ventral hernia repair, but only if appropriate meshes are used. Glue can also serve as an adjunct to mechanical fixation to reduce the number of invasive tacks. Copyright © 2010 American College of Surgeons. Published by Elsevier

  1. The mechanical and biological studies of calcium phosphate cement-fibrin glue for bone reconstruction of rabbit femoral defects

    Directory of Open Access Journals (Sweden)

    Dong J

    2013-03-01

    Full Text Available Jingjing Dong,1,* Geng Cui,2,* Long Bi,1,* Jie Li,3 Wei Lei11Institute of Orthopedics, Xijing Hospital, Fourth Military Medical University, Xi’an, Shaanxi, People’s Republic of China; 2Institute of Orthopedics, General Hospital of PLA, Beijing, People’s Republic of China; 3Institute of Gynecology and Obstetrics, General Hospital of PLA, Beijing, People’s Republic of China*These authors contributed equally to this workAbstract: In order to improve the mechanical and biological properties of calcium phosphate cement (CPC, nanometer-biomaterial for bone reconstruction in the rabbit femoral defect model, fibrin glue (FG, the natural product, purified from the blood was introduced at three different ratios. The CPC powder and the FG solution were mixed, respectively, at the powder/liquid (P/L ratios (g/mL of 1:1, 3:1, and 5:1 (g/mL, and pure CPC was used as a control. After being implanted into the femoral defect in rabbit, the healing process was evaluated by micro-computed tomography scan, biomechanical testing, and histological examination. By micro-computed tomography analysis, the P/L ratio of 1:1 (g/mL group indicated the largest quantity of new bone formation at 4 weeks, 8 weeks, and 12 weeks after implantation, respectively. Bone volume per trabecular volume of the 1:1 group was highest in the four groups, which was 1.45% ± 0.42%, 7.35% ± 1.45%, and 29.10% ± 1.67% at 4 weeks, 8 weeks, and 12 weeks after the operation, respectively. In the biomechanical tests, the compressive strength and the elastic modulus of the three CPC–FG groups were much higher than those of the pure CPC group at the determined time point (P < 0.05. The histological evaluation also showed the best osseointegration in the 1:1 group at 4 weeks, 8 weeks, and 12 weeks after the operation, respectively. In the 1:1 group, the bone grew into the pore of the cement in the laminar arrangement and connected with the cement tightly at the 12th week after the operation

  2. A comparative in vitro study of the viability of human keratinocytes grown on irradiated human amnion membrane and fibrin glue scaffolds

    International Nuclear Information System (INIS)

    Dorai, A.A.; Lim, C.K.; Azman, W.S.; Halim, A.S.

    2008-01-01

    Full text: The dried irradiated human amnion membrane has been used as a biological dressing for various clinical conditions. Being another biological membrane its potential as a scaffold to grow human keratinocytes is not known yet. To compare the growth patterns and cell viability of keratinocytes using fibrin glue and air dried amnion membrane as a scaffold. Keratinocytes were obtained from skin samples of six patients undergoing elective surgery. Fibrin glue (Tisseel, Baxter ) was diluted and used to coat the wells. Human dried amnion membrane was obtained and placed into the 24 well plates. Keratinocytes were seeded into the fibrin and amnion scaffold. Cell viability assay (MTT) was performed after 24, 48 and 72 hours. Finally the measurements were done by the Enzyme-Linked Immunosorbent Assay (ELISA) reader at 570 nm. Six patients consented for the study. The cells growing on the amnion scaffold showed a decreasing trend (20.67%, 17.94% and 16.78% respectively for 24, 48 and 72 hours). The cells growing on the fibrin scaffold showed a steady increase in number at 24, 48 and 72 hours (73.03%, 74.12% and 79.66%). The percentage of growth of normal human keratinocytes were significantly greater in the fibrin scaffold group (Mann - Whitney p = 0.002) for 24, 48 and 72 hours. The air dried irradiated human amnion membrane can be used as a scaffold to grow keratinocytes but however the growth pattern does not sustain with time. Fibrin glue supports the growth of human keratinocytes and shows an increasing pattern of growth with time. (Author)

  3. Traditional Glue, Adhesive and Poison Used for Composite Weapons by Ju/'hoan San in Nyae Nyae, Namibia. Implications for the Evolution of Hunting Equipment in Prehistory.

    Science.gov (United States)

    Wadley, Lyn; Trower, Gary; Backwell, Lucinda; d'Errico, Francesco

    2015-01-01

    Ju/'hoan hunters from Nyae Nyae, near Tsumkwe in Namibia, demonstrate the manufacture of three fixative pastes made from plant extracts, and poison made from grubs and plant extracts. Ammocharis coranica and Terminalia sericea produce simple glue. Ozoroa schinzii latex mixed with carbonized Aristeda adscensionis grass is a compound adhesive. Composite poison is made from Chrysomelid grub viscera mixed with salivary extracts of Acacia mellifera inner bark and the tuber sap of Asparagus exuvialis. In order to document potential variability in the chaîne opératoire, and to eliminate inherent biases associated with unique observations, we studied manufacturing processes in three separate Nyae Nyae villages. Although there are methodological similarities in the Nyae Nyae area, we observed a few differences in contemporary traditions of poison manufacture. For example, some hunters make powder from Asparagus exuvialis tuber sap by boiling, reducing, hardening and grinding it, while others simply use heated sap. The Ju/'hoan hunting kit provides insights for archaeologists, but we must exercise caution when looking for continuity between prehistoric and historical technical systems. Some traditions have been lost to modern hunters, while others are new. We should also expect variability in the Stone Age because of geographically restricted resources. Simple glue, compound adhesive, and poison recipes identified in the Stone Age have no modern equivalents. By about 60,000 years ago at Diepkloof, simple glue was used for hafting tools, but at similarly-aged Sibudu there are recipes that combine red ochre powder with plant and/or animal ingredients. At Border Cave, novel poisons and compound adhesives were used in the Early Later Stone Age. It is possible that the complexity that we record in the manufacture of fixative pastes and poison used by Ju/'hoan hunters represents a hafting system both similar to and different from that observed at the Stone Age sites of Diepkloof

  4. Portal Vein Embolization Using a Nitinol Plug (Amplatzer Vascular Plug) in Combination with Histoacryl Glue and Iodinized Oil: Adequate Hypertrophy with a Reduced Risk of Nontarget Embolization

    International Nuclear Information System (INIS)

    Bent, Clare L.; Low, Deborah; Matson, Matthew B.; Renfrew, Ian; Fotheringham, Tim

    2009-01-01

    The purpose of this study was to assess whether portal vein embolization (PVE) using a nitinol vascular plug in combination with histoacryl glue and iodinized oil minimizes the risk of nontarget embolization while obtaining good levels of future liver remnant (FLR) hypertrophy. Between November 2005 and August 2008, 16 patients (8 females, 8 males; mean age, 63 ± 3.6 years), each with a small FLR, underwent right ipsilateral transhepatic PVE prior to major hepatectomy. Proximal PVE was initially performed by placement of a nitinol vascular plug, followed by distal embolization using a mixture of histoacryl glue and iodinized oil. Pre- and 6 weeks postprocedural FLR volumes were calculated using computed tomographic imaging. Selection for surgery required an FLR of 0.5% of the patient's body mass. Clinical course and outcome of surgical resection for all patients were recorded. At surgery, the ease of hepatectomy was subjectively assessed in comparison to previous experience following PVE with alternative embolic agents. PVE was successful in all patients. Mean procedure time was 30.4 ± 2.5 min. Mean absolute increase in FLR volume was 68.9% ± 12.0% (p = 0.00005). There was no evidence of nontarget embolization during the procedure or on subsequent imaging. Nine patients proceeded to extended hepatectomy. Six patients demonstrated disease progression. One patient did not achieve sufficient hypertrophy in relation to body mass to undergo hepatic resection. At surgery, the hepatobiliary surgeons observed less periportal inflammation compared to previous experience with alternative embolic agents, facilitating dissection at extended hepatectomy. In conclusion, ipsilateral transhepatic PVE using a single nitinol plug in combination with histoacryl glue and iodinized oil simplifies the procedure, offering short procedural times with minimal risk of nontarget embolization. Excellent levels of FLR hypertrophy are achieved enabling safe extended hepatectomy.

  5. Traditional Glue, Adhesive and Poison Used for Composite Weapons by Ju/'hoan San in Nyae Nyae, Namibia. Implications for the Evolution of Hunting Equipment in Prehistory.

    Directory of Open Access Journals (Sweden)

    Lyn Wadley

    Full Text Available Ju/'hoan hunters from Nyae Nyae, near Tsumkwe in Namibia, demonstrate the manufacture of three fixative pastes made from plant extracts, and poison made from grubs and plant extracts. Ammocharis coranica and Terminalia sericea produce simple glue. Ozoroa schinzii latex mixed with carbonized Aristeda adscensionis grass is a compound adhesive. Composite poison is made from Chrysomelid grub viscera mixed with salivary extracts of Acacia mellifera inner bark and the tuber sap of Asparagus exuvialis. In order to document potential variability in the chaîne opératoire, and to eliminate inherent biases associated with unique observations, we studied manufacturing processes in three separate Nyae Nyae villages. Although there are methodological similarities in the Nyae Nyae area, we observed a few differences in contemporary traditions of poison manufacture. For example, some hunters make powder from Asparagus exuvialis tuber sap by boiling, reducing, hardening and grinding it, while others simply use heated sap. The Ju/'hoan hunting kit provides insights for archaeologists, but we must exercise caution when looking for continuity between prehistoric and historical technical systems. Some traditions have been lost to modern hunters, while others are new. We should also expect variability in the Stone Age because of geographically restricted resources. Simple glue, compound adhesive, and poison recipes identified in the Stone Age have no modern equivalents. By about 60,000 years ago at Diepkloof, simple glue was used for hafting tools, but at similarly-aged Sibudu there are recipes that combine red ochre powder with plant and/or animal ingredients. At Border Cave, novel poisons and compound adhesives were used in the Early Later Stone Age. It is possible that the complexity that we record in the manufacture of fixative pastes and poison used by Ju/'hoan hunters represents a hafting system both similar to and different from that observed at the Stone

  6. Parameter estimation of a two-horizon soil profile by combining crop canopy and surface soil moisture observations using GLUE

    Science.gov (United States)

    Sreelash, K.; Sekhar, M.; Ruiz, L.; Tomer, S. K.; Guérif, M.; Buis, S.; Durand, P.; Gascuel-Odoux, C.

    2012-08-01

    SummaryEstimation of soil parameters by inverse modeling using observations on either surface soil moisture or crop variables has been successfully attempted in many studies, but difficulties to estimate root zone properties arise when heterogeneous layered soils are considered. The objective of this study was to explore the potential of combining observations on surface soil moisture and crop variables - leaf area index (LAI) and above-ground biomass for estimating soil parameters (water holding capacity and soil depth) in a two-layered soil system using inversion of the crop model STICS. This was performed using GLUE method on a synthetic data set on varying soil types and on a data set from a field experiment carried out in two maize plots in South India. The main results were (i) combination of surface soil moisture and above-ground biomass provided consistently good estimates with small uncertainity of soil properties for the two soil layers, for a wide range of soil paramater values, both in the synthetic and the field experiment, (ii) above-ground biomass was found to give relatively better estimates and lower uncertainty than LAI when combined with surface soil moisture, especially for estimation of soil depth, (iii) surface soil moisture data, either alone or combined with crop variables, provided a very good estimate of the water holding capacity of the upper soil layer with very small uncertainty whereas using the surface soil moisture alone gave very poor estimates of the soil properties of the deeper layer, and (iv) using crop variables alone (else above-ground biomass or LAI) provided reasonable estimates of the deeper layer properties depending on the soil type but provided poor estimates of the first layer properties. The robustness of combining observations of the surface soil moisture and the above-ground biomass for estimating two layer soil properties, which was demonstrated using both synthetic and field experiments in this study, needs now to

  7. Staple Line Reinforcement During Laparoscopic Sleeve Gastrectomy: Absorbable Monofilament, Barbed Suture, Fibrin Glue, or Nothing? Results of a Prospective Randomized Study.

    Science.gov (United States)

    Carandina, S; Tabbara, M; Bossi, M; Valenti, A; Polliand, C; Genser, L; Barrat, Christophe

    2016-02-01

    Laparoscopic sleeve gastrectomy (LSG) is associated with serious complications, such as staple line (SL) leaks and bleeding. In order to prevent the occurrence of these complications, surgeons have advocated the need to strengthen the staple line. The aim of this randomized controlled study was to compare the efficacy of three different ways of strengthening of the SL in LSG in preventing surgical post-operative complications. Between April 2012 and December 2014, 600 patients (pts) scheduled for LSG were prospectively randomized into groups without SL reinforcement (group A) or with SL reinforcement including fibrin glue coverage (group B), or oversewn SL with imbricating absorbable (Monocryl™; group C) or barbed (V lock®) running suture (group D). Primary endpoints were post-operative leaks, bleeding, and stenosis, while secondary outcomes consisted of the time to perform the staple line reinforcement (SLR) and total operative time. Mean SLR operative time was lower for group B (3.4 ± 1.3 min) compared with that for groups C (26.8 ± 8.5 min) and D (21.1 ± 8.4 min) (p running suture or with fibrin glue, is an unrewarding surgical act with the sole effect of prolonging the operative time.

  8. Synthetic spider silk fibers spun from Pyriform Spidroin 2, a glue silk protein discovered in orb-weaving spider attachment discs.

    Science.gov (United States)

    Geurts, Paul; Zhao, Liang; Hsia, Yang; Gnesa, Eric; Tang, Simon; Jeffery, Felicia; La Mattina, Coby; Franz, Andreas; Larkin, Leah; Vierra, Craig

    2010-12-13

    Spider attachment disc silk fibers are spun into a viscous liquid that rapidly solidifies, gluing dragline silk fibers to substrates for locomotion or web construction. Here we report the identification and artificial spinning of a novel attachment disc glue silk fibroin, Pyriform Spidroin 2 (PySp2), from the golden orb weaver Nephila clavipes . MS studies support PySp2 is a constituent of the pyriform gland that is spun into attachment discs. Analysis of the PySp2 protein architecture reveals sequence divergence relative to the other silk family members, including the cob weaver glue silk fibroin PySp1. PySp2 contains internal block repeats that consist of two subrepeat units: one dominated by Ser, Gln, and Ala and the other Pro-rich. Artificial spinning of recombinant PySp2 truncations shows that the Ser-Gln-Ala-rich subrepeat is sufficient for the assembly of polymeric subunits and subsequent fiber formation. These studies support that both orb- and cob-weaving spiders have evolved highly polar block-repeat sequences with the ability to self-assemble into fibers, suggesting a strategy to allow fiber fabrication in the liquid environment of the attachment discs.

  9. NATO's Nuclear Glue

    National Research Council Canada - National Science Library

    Horton, Scott T

    2007-01-01

    .... nuclear weapons prepositioned in Europe? This paper reviews the past and current role of US nuclear forces in NATO, considers future nuclear policy options, and discusses potential consequences of those decisions...

  10. Fibrin glue instillation under skin flaps to prevent seroma-related morbidity following breast and axillary surgery.

    Science.gov (United States)

    Sajid, Muhammad S; Hutson, Kristian H; Rapisarda, Ignazio F; Bonomi, Riccardo

    2013-05-31

    Fibrin glue (FG) combines fibrinogen and thrombin, under the presence of factor XIII and calcium chloride, and produces a 'fibrin clot' as would occur through the natural clotting cascade. FG is thought to close over any small vessels including lymphatics that are too small for conventional surgical closure, thereby reducing seroma formation, seroma incidence and related comorbidities. To assess the evidence on the effectiveness of FG in people undergoing breast and axillary surgery and to establish whether FG is an efficient modality to prevent postoperative seroma and seroma-related outcomes. We searched the Cochrane Breast Cancer Group's (CBCG) Specialised Register (9 December 2011), the Cochrane Central Register of Controlled Trials (CENTRAL, Issue 1 2012), MEDLINE (9 December 2011), EMBASE (9 December 2011), LILACS (22 October 2012), SCI-E (22 October 2012), the World Health Organization's International Clinical Trial Registry (9 December 2011) and ClinicalTrials.gov (22 October 2012). Randomised controlled trials (RCTs) comparing the effectiveness of FG in terms of reducing the postoperative seroma incidence and related comorbidities in people undergoing breast and axillary surgery. At least two review authors independently scrutinised search results, selected eligible studies and extracted the data. The pooled analysis of the extracted data was achieved by the statistical analysis on Review Manager software. The quality of studies was assessed using The Cochrane Collaboration's 'Risk of bias' tool. The search of four standard electronic databases yielded 119 potentially relevant studies but only 18 RCTs involving 1252 people were found suitable for statistical analysis. There was significant heterogeneity among trials and the majority of trials were of poor quality. The use of FG under skin flaps following breast and axillary surgery failed to reduce the incidence of postoperative seroma (risk ratio (RR) 1.02; 95% Confidence Interval (CI) 0.90 to 1.16, P

  11. Endolymphatic Ethiodized Oil Intranodal Lymphangiography and Cyanoacrylate Glue Embolization for the Treatment of Postoperative Lymphatic Leak After Robot-Assisted Laparoscopic Pelvic Resection.

    Science.gov (United States)

    Hill, Hannah; Srinivasa, Ravi N; Gemmete, Joseph J; Hage, Anthony; Bundy, Jacob; Chick, Jeffrey Forris Beecham

    2018-01-01

    Purpose: To report the approach, technical success, clinical outcomes, complications, and follow-up of ethiodized oil intranodal lymphangiography with cyanoacrylate glue embolization for the treatment of lymphatic leak after robot-assisted laparoscopic pelvic resection. Materials and Methods: Four men with mean age 68.7 ± 14.3 years were treated with ethiodized oil intranodal lymphangiography with cyanoacrylate embolization for postoperative lymphatic leak. Patients underwent either (1) cystoprostatectomy with ileal conduit and bilateral extensive pelvic lymph node dissection for muscle-invasive urothelial carcinoma and presented with postoperative lymphatic ascites ( n  = 2) or (2) prostatectomy with bilateral standard pelvic lymph node dissection for prostate carcinoma and presented with postoperative pelvic lymphoceles ( n  = 2). Intranodal lymphangiography and embolization procedural details, technical success, clinical outcomes, and follow-up were recorded. Results: In four patients, a total of six ethiodized oil intranodal lymphangiograms were performed, two procedures being repeated interventions. Inguinal lymph node catheterization and ethiodized oil lymphangiography was technically effective in all procedures. A mean of 5.2 ± 2.0 mL of ethiodized oil was used for lymphatic opacification. Cyanoacrylate was diluted to 24.2% with ethiodized oil and 0.44 mL of cyanoacrylate was instilled during first time interventions. On repeat procedures, cyanoacrylate was diluted to 51.7%, and 0.52 mL was instilled. The primary clinical success rate was 50% ( n  = 2/4). Clinical success was achieved in all patients after two interventions ( n  = 4; 100%). No complications were reported at mean follow-up of 134.7 ± 79.2 days (range: 59-248 days). Conclusion: Ethiodized oil intranodal lymphangiography with direct cyanoacrylate glue embolization is a minimally invasive treatment option for lymphatic leak after pelvic resection.

  12. Development of the Tagger Microscope & Analysis of Spin Density Matrix Elements in gamma-p -> phi-p for the GlueX Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Barnes, Alexander E. [Carnegie Mellon Univ., Pittsburgh, PA (United States); Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2017-05-31

    The quark model has been successful in classifying the spectrum of mesons observed since the 1960s, however, it fails to explain some of the measured bound states. Lattice QCD predictions have shown that an excited gluonic field may contribute to the quantum numbers of the bound state and form hybrid mesons, qq-bar-g, where g is a constituent gluon. It is possible for some hybrids to possess quantum numbers forbidden by the quark model and are known as \\smoking gun" hybrids due to their lack of mixing with conventional qq-bar states. The GlueX photoproduction experiment at Jefferson Lab in Newport News, VA is designed to study hybrid mesons and to map their spectrum. A 12 GeV electron beam produces 9 GeV linearly polarized photons via coherent bremsstrahlung in a diamond radiator which are incident on a liquid H2 target. In order to determine the photon energy, the use of a tagging spectrometer which measures the energy of the post-bremsstrahlung electron is required. The tagger microscope is a scintillating fiber detector designed to measure the energy of electrons corresponding to the polarized photons. The main focus of this work is the design and construction of the tagger microscope electronics as well as the calibration of the microscope within the experiment. Additionally, the analysis of the reaction gamma-p -> phi-p, where phi (1020) -> K+K-, is discussed. This analysis provides a high-level calibration for GlueX in regards to understanding the acceptance and sensitivity of the detectors to mesons with strange quark content. By studying the phi with linearly polarized photons, information on the production mechanism can be extracted. The measurement of the phi spin-density matrix elements are shown and compared with past data which are found to be in agreement.

  13. Efficacy, Reliability, and Safety of Completely Autologous Fibrin Glue in Neurosurgical Procedures: Single-Center Retrospective Large-Number Case Study.

    Science.gov (United States)

    Nakayama, Noriyuki; Yano, Hirohito; Egashira, Yusuke; Enomoto, Yukiko; Ohe, Naoyuki; Kanemura, Nobuhiro; Kitagawa, Junichi; Iwama, Toru

    2018-01-01

    Commercially available fibrin glue (Com-FG), which is used commonly worldwide, is produced with pooled human plasma from multiple donors. However, it has added bovine aprotinin, which involves the risk of infection, allogenic immunity, and allergic reactions. We evaluate the efficacy, reliability, and safety of completely autologous fibrin glue (CAFG). From August 2014 to February 2016, prospective data were collected and analyzed from 153 patients. CAFG was prepared with the CryoSeal System using autologous blood and was applied during neurosurgical procedures. Using CAFG-soaked oxidized regenerated cellulose and/or polyglycolic acid sheets, we performed a pinpoint hemostasis, transposed the offending vessels in a microvascular decompression, and covered the dural incision to prevent cerebrospinal fluid leakage. The CryoSeal System had generated up to a mean of 4.51 mL (range, 3.0-8.4 mL) of CAFG from 400 mL autologous blood. Com-FG products were not used in our procedures. Only 6 patients required an additional allogeneic blood transfusion. The hemostatic effective rate was 96.1% (147 of 153 patients). Only 1 patient who received transsphenoidal surgery for a pituitary adenoma presented with the complication of delayed postoperative cerebrospinal fluid leakage (0.65%). No patient developed allergic reactions or systemic complications associated with the use of CAFG. CAFG effectively provides hemostatic, adhesive, and safety performance. The timing and three-dimensional shape of CAFG-soaked oxidized regenerated cellulose and/or polyglycolic acid sheets solidification can be controlled with slow fibrin formation. The cost to prepare CAFG is similar compared with Com-FG products, and it can therefore be easily used at most institutions. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Utilização de adesivo de fibrina em cirurgias oftalmológicas Use of fibrin glue in ocular surgery

    Directory of Open Access Journals (Sweden)

    Melissa Manfroi Dal Pizzol

    2009-06-01

    Full Text Available OBJETIVO: Avaliar as diferentes técnicas cirúrgicas oftalmológicas nas quais se pode utilizar a cola biológica e possíveis complicações relacionadas ao seu uso. MÉTODOS: Estudo de série de casos retrospectivo, não-comparativo. Foram avaliados 161 olhos de pacientes com idade média de 51,8 anos em que foi utilizada cola biológica (Beriplast P® - Aventis Behring, Alemanha para fixação de tecido ou fechamento incisional. RESULTADOS: Foram avaliados 76 pacientes com pterígio, 4 com ceratoconjuntivite límbica superior, 4 com tumor limbar, 21 com conjuntivocálase, 31 com ceratopatia bolhosa, 7 com deficiência límbica, 6 com queimadura alcalina, 2 com Stevens-Johnson, 5 com catarata e 5 com glaucoma. Complicações foram relatas em 28 casos (17,4%. Descolamento do tecido fixado e granuloma foram as complicações mais frequentes. Descolamento ocorreu em 10 casos (5,6% (7 em transplante de membrana amniótica em ceratopatia bolhosa, 2 em transplante de conjuntiva autólogo após exérese de pterígio, 1 após transplante de limbo autólogo por Stevens-Johnson. Granuloma ocorreu em 9 casos (5,6% (5 em pacientes com queimadura alcalina aguda tratados com transplante de membrana amniótica, 1 em paciente com sequela de queimadura tratado com transplante de limbo autólogo e 3 em pacientes após exérese de pterígio tratados com transplante de conjuntiva autólogo. Todas as complicações ocorreram dentro da primeira semana de pós-operatório. CONCLUSÃO: Embora o presente seja retrospectivo e não-comparativo, podemos observar que a utilização do adesivo de fibrina parece ser segura e efetiva, além de apresentar baixas taxas de complicações nas cirurgias de superfície ocular e de segmento anterior.PURPOSE: To evaluate the use of fibrin glue and its complications in different ophthalmic surgeries. METHODS: A retrospective and non-comparative case series study. 161 eyes were evaluated. The mean age was 51.8 years. Fibrin glue

  15. Analysis of the η(548) ->π+π-π0 and η'(958) ->π+π- η channels using a 8-9 GeV tagged photon beam for the GlueX Experiment

    Science.gov (United States)

    Beattie, Tegan; Papandreou, Zisis; Stevens, Justin; GlueX Collaboration

    2016-09-01

    The primary goal of the GlueX experiment is to conduct a definitive mapping of states in the light meson sector with an emphasis on searching for exotic hybrid mesons as evidence of gluonic excitations. The experiment, housed in the Hall-D facility at Jefferson Lab following its accelerator upgrade to 12 GeV, is now entering the physics data taking phase. The η(548) and η'(958) mesons are two of the richest unflavoured light mesons readily available at GlueX energies for studying resonances. Many other light mesons have decay channels involving the η mesons with significant branching ratios, and πη / πη' resonances are among the top contenders for possibly-accessible exotic and hybrid resonances which GlueX aims to study. As such, the ability to reconstruct pure η/η' samples and analyze their decays is of utmost importance for understanding future work on more complicated analyses. Preliminary analysis results from commissioning data will be presented. This work was supported by NSERC Grant SAPJ-326516 and Jefferson Science Associates, LLC, who operates Jefferson Lab under U.S. DOE Contract No. DE-AC05-06OR23177.

  16. Electrically conductive poly-ɛ-caprolactone/polyethylene glycol/multi-wall carbon nanotube nanocomposite scaffolds coated with fibrin glue for myocardial tissue engineering

    Science.gov (United States)

    Mehdikhani, Mehdi; Ghaziof, Sharareh

    2018-01-01

    In this research, poly-ɛ-caprolactone (PCL), polyethylene glycol (PEG), multi-wall carbon nanotubes (MWCNTs), and nanocomposite scaffolds containing 0.5 and 1% (w/w) MWCNTs coated with fibrin glue (FG) were prepared via solvent casting and freeze-drying technique for cardiac tissue engineering. Scanning electron microscopy, transmission electron microscopy, Fourier transform-infrared spectroscopy, and X-ray diffraction were used to characterize the samples. Furthermore, mechanical properties, electrical conductivity, degradation, contact angle, and cytotoxicity of the samples were evaluated. Results showed the uniform distribution of the MWCNTs with some aggregates in the prepared nanocomposite scaffolds. The scaffolds containing 1% (w/w) MWCNTs with and without FG coating illustrated optimum modulus of elasticity, high electrical conductivity, and wettability compared with PCL/PEG and PCL/PEG/0.5%(w/w) MWCNTs' scaffolds. FG coating enhanced electrical conductivity and cell response, and increased wettability of the constructs. The prepared scaffolds were degraded significantly after 60 days of immersion in PBS. Meanwhile, the nanocomposite containing 1% (w/w) MWCNTs with FG coating (S3) showed proper spreading and viability of the myoblasts seeded on it after 1, 4, and 7 days of culture. The scaffold containing 1% (w/w) MWCNTs with FG coating demonstrated optimal properties including acceptable mechanical properties, proper wettability, high electrical conductivity, satisfactory degradation, and excellent myoblasts response to it.

  17. Crystal water as the mol-ecular glue for obtaining different co-crystal ratios: the case of gallic acid tris-caffeine hexa-hydrate.

    Science.gov (United States)

    Vella-Zarb, L; Baisch, U

    2018-04-01

    The crystal structure of the hexa-hydrate co-crystal of gallic acid and caffeine, C 7 H 6 O 5 ·3C 8 H 10 N 4 O 2 ·6H 2 O or GAL3CAF·6H 2 O , is a remarkable example of the importance of hydrate water acting as structural glue to facilitate the crystallization of two components of different stoichiometries and thus to compensate an imbalance of hydrogen-bond donors and acceptors. The water mol-ecules provide the additional hydrogen bonds required to form a crystalline solid. Whereas the majority of hydrogen bonds forming the inter-molecular network between gallic acid and caffeine are formed by crystal water, only one direct classical hydrogen bond between two mol-ecules is formed between the carb-oxy-lic oxygen of gallic acid and the carbonyl oxygen of caffeine with d ( D ⋯ A ) = 2.672 (2) Å. All other hydrogen bonds either involve crystal water or utilize protonated carbon atoms as donors.

  18. Automated double-cone-beam CT fusion technique. Enhanced evaluation of glue distribution in cases of spinal dural arteriovenous fistula (SDAVF) embolisation

    International Nuclear Information System (INIS)

    Farago, Giuseppe; Caldiera, V.; Antozzi, C.; Bellino, A.; Innocenti, A.; Ciceri, E.

    2017-01-01

    Spinal dural arteriovenous fistulas (SDAVFs) are acquired diseases that represent the majority of all arteriovenous spinal shunts, leading to progressive and disabling myelopathy. Treatment is focused on accurately disconnecting the fistula point. We present our experience with the double-cone-beam CT fusion technique successfully applied to evaluate treatment results in a series of SDAVFs. Between November 2011 and December 2015 we performed double-DynaCT acquisition (pre- and post-embolisation) in 12 cases of SDAVF. A successful DynaCT fusion technique was only achieved in the group of patients with pre- and post-treatment images acquired at the same time as the treatment session, under general anaesthesia (4/12). DynaCT performed on different days proved to be inadequate for the automated fusion technique because of changes in the body position (8/12). A pre-treatment flat-panel cone-beam CT with contrast, at the time of diagnostic angiography, can be very helpful to detect the correct level of the fistula and the relationship between the fistula and the surrounding structures. In case of the endovascular approach, additional post-treatment native acquisition merged with the pre-treatment acquisition (double-cone-beam CT fusion technique) permits to immediately evaluate the distribution of the glue cast and to confirm the success of the procedure. (orig.)

  19. Treatment of non-healing sternum wound after open-heart surgery with allogenic platelet-rich plasma and fibrin glue-preliminary outcomes

    Directory of Open Access Journals (Sweden)

    Mohammad Abbasi Tashnizi

    2013-01-01

    Full Text Available Introduction: Non-healing wound in the sternal region after coronary arteries bypass graft surgery is a serious complication. For healing a chronic wound, several novel approaches have been proposed recently such as using bone marrow stem cells, platelets and fibrin glue (PFG; but a non-invasive method is highly desirable in the first approach for treatment. The current study was undertaken to evaluate the effect of the combination of PFG in one treatment. Materials and Methods: We report on the treatment of six patients with life-threatening chronic sternum wounds, which caused septicemia with multi-drug resistant pathogens. The ulcers were extensively debrided initially and were measured and photographed at weekly intervals. The combination of PFG was applied topically on the wound after every 2 days. Results: The wounds were completely closed in five patients and significantly reduced in size in one. There was no evidence of local or systemic complications and any abnormal tissue formation, keloid or hypertrophic scarring. Conclusions: Our study suggests, in the first approach, PFG can be used safely in order to heal a non healing sternum wound following coronary artery bypass surgery.

  20. Automated double-cone-beam CT fusion technique. Enhanced evaluation of glue distribution in cases of spinal dural arteriovenous fistula (SDAVF) embolisation

    Energy Technology Data Exchange (ETDEWEB)

    Farago, Giuseppe [Foundation Neurological Institute ' ' C. Besta' ' , Department of Interventional Neuroradiology, Milan (Italy); Fondazione IRCCS Istituto Neurologico Carlo Besta, Department of Interventional Neuroradiology, Milan (Italy); Caldiera, V. [Foundation Neurological Institute ' ' C. Besta' ' , Department of Interventional Neuroradiology, Milan (Italy); Antozzi, C.; Bellino, A. [Foundation Neurological Institute ' ' C. Besta' ' , Department of Neuroimmunology and Neuromuscular Diseases, Milan (Italy); Innocenti, A. [Foundation Neurological Institute ' ' C. Besta' ' , Department of Neuro-Oncology, Milan (Italy); Ciceri, E. [Foundation Neurological Institute ' ' C. Besta' ' , Department of Interventional Neuroradiology, Milan (Italy); Azienda Ospedaliera Universitaria Integrata Borgo Trento, Department of Neuroradiology, Verona (Italy)

    2017-05-15

    Spinal dural arteriovenous fistulas (SDAVFs) are acquired diseases that represent the majority of all arteriovenous spinal shunts, leading to progressive and disabling myelopathy. Treatment is focused on accurately disconnecting the fistula point. We present our experience with the double-cone-beam CT fusion technique successfully applied to evaluate treatment results in a series of SDAVFs. Between November 2011 and December 2015 we performed double-DynaCT acquisition (pre- and post-embolisation) in 12 cases of SDAVF. A successful DynaCT fusion technique was only achieved in the group of patients with pre- and post-treatment images acquired at the same time as the treatment session, under general anaesthesia (4/12). DynaCT performed on different days proved to be inadequate for the automated fusion technique because of changes in the body position (8/12). A pre-treatment flat-panel cone-beam CT with contrast, at the time of diagnostic angiography, can be very helpful to detect the correct level of the fistula and the relationship between the fistula and the surrounding structures. In case of the endovascular approach, additional post-treatment native acquisition merged with the pre-treatment acquisition (double-cone-beam CT fusion technique) permits to immediately evaluate the distribution of the glue cast and to confirm the success of the procedure. (orig.)

  1. A case grafted with polyglycolic acid sheets and fibrin glue for protection after temporary resection of a metastatic cervical skin tumor.

    Science.gov (United States)

    Matsuzuka, Takashi; Suzuki, Masahiro; Ikeda, Masakazu; Sato, Kaoru; Fujimoto, Junko; Hosaka, Rumi; Tanji, Yuko; Soeda, Shu; Murono, Shigeyuki

    2018-04-01

    The aim of this case report was to evaluate the usefulness of a grafting with polyglycolic acid sheet and a fibrin glue spray (PGA sheet grafting) after resection of a cervical skin tumor. A 61-year-old woman presented with left cervical skin tumor resistance to chemo-radiotherapy. She had been undergoing multimodal therapy for ovarian serous papillary adenocarcinoma for the previous six years. Although she had a poor general condition and a cervical skin tumor of 9cm in diameter, which was painful and easy bleeding, had offensive smell, she hoped to return to her job. Under local anesthesia, resection was performed, and PGA sheet grafting were used to shield the skin defect. After resection, she was relieved from pain, and could stay home without daily wound treatment. One and half months after resection, the wound was almost epithelialized. The PGA sheets consist of soft, elastic, nonwoven fabric made of PGA. In recent years, PGA sheet grafting has been widely used in the reconstruction and was chosen to shield the skin defect for this case. PGA sheet grafting after resection of cervical skin tumor can be an acceptable method for palliative care to relieve pain, bleeding, offensive smell, and ugly appearance. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Lime-based restoration paints: characterization and evaluation of formulations using a native species from the Amazon flora and PVA-based glue as additives

    Directory of Open Access Journals (Sweden)

    Mayra Martins Silva

    Full Text Available Abstract Based on historic documents, two lime-based paint formulations were produced in laboratory in order to evaluate their basic characteristics as restoration materials for historic buildings with lime-based components. The paints were made basically with hydrated lime, clay, water and linseed (Linum usitatissimum L. oil, and one formulation had PVA (polyvinyl acetate-based glue as fixative, and the other one, Couma guianensis' latex. Each paint component was characterized by XRD and FTIR, and color and specular gloss measurements were performed on both paints. A preliminary assessment of the paints was conducted using the Pipe Method, the salt crystallization test, visual analysis for dustiness, and analysis of microbiological growth. The results showed that the laboratory-produced paints are theoretically and technologically compatible with lime-based coatings, however, their superficial performance can be improved to achieve greater durability. This study also brings to light local materials from the Amazon region that have great potential to be used and recognized as raw materials for paints and which could also be investigated for other uses.

  3. Does an Injection of Adipose-Derived Mesenchymal Stem Cells Loaded in Fibrin Glue Influence Rotator Cuff Repair Outcomes? A Clinical and Magnetic Resonance Imaging Study.

    Science.gov (United States)

    Kim, Yong Sang; Sung, Chang Hun; Chung, Sung Hoon; Kwak, Sang Joon; Koh, Yong Gon

    2017-07-01

    The mesenchymal stem cell (MSC)-based tissue engineering approach has been developed to improve the treatment of rotator cuff tears. Hypothesis/Purpose: The purpose was to determine the effect of an injection of adipose-derived MSCs loaded in fibrin glue during arthroscopic rotator cuff repair on clinical outcomes and to evaluate its effect on structural integrity using magnetic resonance imaging (MRI). The hypothesis was that the application of adipose-derived MSCs would improve outcomes after the surgical repair of a rotator cuff tear. Cohort study; Level of evidence, 3. Among 182 patients treated with arthroscopic surgery for a rotator cuff tear, 35 patients treated with arthroscopic rotator cuff repair alone (conventional group) were matched with 35 patients who underwent arthroscopic rotator cuff repair with an injection of adipose-derived MSCs loaded in fibrin glue (injection group) based on sex, age, and lesion size. Outcomes were assessed with respect to the visual analog scale (VAS) for pain, range of motion (ROM) (including forward flexion, external rotation at the side, and internal rotation at the back), and functional measures of the Constant score and University of California, Los Angeles (UCLA) shoulder rating scale. Repaired tendon structural integrity was assessed by using MRI at a minimum of 12 months after surgery, and the mean clinical follow-up was 28.8 ± 4.2 months in the conventional group and 28.3 ± 3.8 months in the injection group. The mean VAS score at rest and during motion improved significantly in both groups after surgery. However, there were no significant differences between the groups at the final follow-up ( P = .256 and .776, respectively). Compared with preoperative measurements, forward flexion and external rotation at the side significantly improved at the final follow-up in both groups (all P rotation at the back were observed in either group ( P = .625 and .834 for the conventional and injection groups, respectively

  4. Three-dimensional printing spiders: back-and-forth glue application yields silk anchorages with high pull-off resistance under varying loading situations.

    Science.gov (United States)

    Wolff, Jonas O; Herberstein, Marie E

    2017-02-01

    The anchorage of structures is a crucial element of construction, both for humans and animals. Spiders use adhesive plaques to attach silk threads to substrates. Both biological and artificial adhesive structures usually have an optimal loading angle, and are prone to varying loading situations. Silk anchorages, however, must cope with loading in highly variable directions. Here we show that the detachment forces of thread anchorages of orb-web spiders are highly robust against pulling in different directions. This is gained by a two-step back-and-forth spinning pattern during the rapid production of the adhesive plaque, which shifts the thread insertion point towards the plaque centre and forms a flexible tree root-like network of branching fibres around the loading point. Using a morphometric approach and a tape-and-thread model we show that neither area, nor width of the plaque, but the shift of the loading point towards the plaque centre has the highest effect on pull-off resistance. This is explained by a circular propagation of the delamination crack with a low peeling angle. We further show that silken attachment discs are highly directional and adjusted to provide maximal performance in the upstream dragline. These results show that the way the glue is applied, crucially enhances the toughness of the anchorage without the need of additional material intake. This work is a starting point to study the evolution of tough and universal thread anchorages among spiders, and to develop bioinspired 'instant' anchorages of thread- and cable-like structures to a broad bandwidth of substrates. © 2017 The Author(s).

  5. Endoscopic debridement and fibrin glue injection of a chronic Morel-Lavallée lesion of the knee in a professional soccer player: A case report and literature review.

    Science.gov (United States)

    Koc, Baris B; Somorjai, Nicolaas; P M Kiesouw, Egid; Vanderdood, Kurt; Meesters-Caberg, Marleen; Draijer, Frits W; Jansen, Edwin J P

    2017-01-01

    A Morel-Lavallée lesion is a post-traumatic closed degloving injury of soft tissue. The lesion is due to a shearing trauma with separation of subcutaneous tissue from underlying fascia. When conservative treatment fails, surgical treatment is imperative. Commonly, open drainage and debridement is performed. This case report describes a Morel-Lavallée lesion of the knee in a professional soccer player who was successfully treated with endoscopic debridement and fibrin glue injection after failure of conservative management. This method achieves the goal of an open surgical debridement without exposing patients to an increased morbidity. Copyright © 2016. Published by Elsevier B.V.

  6. Quantum-dot-sensitized solar cells fabricated by the combined process of the direct attachment of colloidal CdSe quantum dots having a ZnS glue layer and spray pyrolysis deposition.

    Science.gov (United States)

    Im, Sang Hyuk; Lee, Yong Hui; Seok, Sang Il; Kim, Sung Woo; Kim, Sang-Wook

    2010-12-07

    We were able to attach CdSe quantum dots (QDs) having a ZnS inorganic glue layer directly to a mesoporous TiO(2) (mp-TiO(2)) surface by spray coating and thermal annealing. Quantum-dot-sensitized solar cells based on CdSe QDs having ZnS as the inorganic glue layer could easily transport generated charge carriers because of the intimate bonding between CdSe and mp-TiO(2). The application of spray pyrolysis deposition (SPD) to obtain additional CdSe layers improved the performance characteristics to V(oc) = 0.45 V, J(sc) = 10.7 mA/cm(2), fill factor = 35.8%, and power conversion efficiency = 1.7%. Furthermore, ZnS post-treatment improved the device performance to V(oc) = 0.57 V, J(sc) = 11.2 mA/cm(2), fill factor = 35.4%, and power conversion efficiency = 2.2%.

  7. Superposition as a logical glue

    Directory of Open Access Journals (Sweden)

    Andrea Asperti

    2011-03-01

    Full Text Available The typical mathematical language systematically exploits notational and logical abuses whose resolution requires not just the knowledge of domain specific notation and conventions, but not trivial skills in the given mathematical discipline. A large part of this background knowledge is expressed in form of equalities and isomorphisms, allowing mathematicians to freely move between different incarnations of the same entity without even mentioning the transformation. Providing ITP-systems with similar capabilities seems to be a major way to improve their intelligence, and to ease the communication between the user and the machine. The present paper discusses our experience of integration of a superposition calculus within the Matita interactive prover, providing in particular a very flexible, "smart" application tactic, and a simple, innovative approach to automation.

  8. Enhanced angiogenesis and osteogenesis in critical bone defects by the controlled release of BMP-2 and VEGF: implantation of electron beam melting-fabricated porous Ti6Al4V scaffolds incorporating growth factor-doped fibrin glue

    International Nuclear Information System (INIS)

    Lv, Jia; Xiu, Peng; Tan, Jie; Cai, Hong; Liu, Zhongjun; Jia, Zhaojun

    2015-01-01

    Electron beam melting (EBM)-fabricated porous titanium implants possessing low elastic moduli and tailored structures are promising biomaterials for orthopedic applications. However, the bio-inert nature of porous titanium makes reinforcement with growth factors (GFs) a promising method to enhance implant in vivo performance. Bone-morphogenic protein-2 (BMP-2) and vascular endothelial growth factor (VEGF) are key factors of angiogenesis and osteogenesis. Therefore, the present study is aimed at evaluating EBM-fabricated porous titanium implants incorporating GF-doped fibrin glue (FG) as composite scaffolds providing GFs for improvement of angiogenesis and osteogenesis in rabbit femoral condyle defects. BMP-2 and VEGF were added into the constituent compounds of FG, and then this GF-doped FG was subsequently injected into the porous scaffolds. In five groups of implants, angiogenesis and osteogenesis were evaluated at 4 weeks post-implantation using Microfil perfusion and histological analysis: eTi (empty scaffolds), cTi (containing undoped FG), BMP/cTi (containing 50 μg rhBMP-2), VEGF/cTi (containing 0.5 μg VEGF) and Dual/cTi (containing 50 μg rhBMP-2 and 0.5 μg VEGF). The results demonstrate that these composite implants are biocompatible and provide the desired gradual release of the bioactive growth factors. Incorporation of GF delivery, whether a single factor or dual factors, significantly enhanced both angiogenesis and osteogenesis inside the porous scaffolds. However, the synergistic effect of the dual factors combination was observable on angiogenesis but absent on osteogenesis. In conclusion, fibrin glue is a biocompatible material that could be employed as a delivery vehicle in EBM-fabricated porous titanium for controlled release of BMP-2 and VEGF. Application of this method for loading a porous titanium scaffold to incorporate growth factors is a convenient and promising strategy for improving osteogenesis of critical-sized bone defects

  9. Molecular glues for manipulating enzymes: trypsin inhibition by benzamidine-conjugated molecular glues† †Electronic supplementary information (ESI) available: Synthesis of TEG–BA, Gluen–BA, mGluen–BA and Gluen–Ph; 1H NMR, 13C NMR, MALDI-TOF MS, electronic absorption, and CD spectra; zeta potential distributions; SLS plots; DLS histograms; and related experimental procedures. See DOI: 10.1039/c5sc00524h Click here for additional data file.

    Science.gov (United States)

    Mogaki, Rina

    2015-01-01

    Water-soluble bioadhesive polymers bearing multiple guanidinium ion (Gu+) pendants at their side-chain termini (Gluen–BA, n = 10 and 29) that were conjugated with benzamidine (BA) as a trypsin inhibitor were developed. The Gluen–BA molecules are supposed to adhere to oxyanionic regions of the trypsin surface, even in buffer, via a multivalent Gu+/oxyanion salt-bridge interaction, such that their BA group properly blocks the substrate-binding site. In fact, Glue10–BA and Glue29–BA exhibited 35- and 200-fold higher affinities for trypsin, respectively, than a BA derivative without the glue moiety (TEG–BA). Most importantly, Glue10–BA inhibited the protease activity of trypsin 13-fold more than TEG–BA. In sharp contrast, mGlue27–BA, which bears 27 Gu+ units along the main chain and has a 5-fold higher affinity than TEG–BA for trypsin, was inferior even to TEG–BA for trypsin inhibition. PMID:28706668

  10. Anastomose do nervo facial de coelhos com cola de fibrina: estudo da velocidade de condução nervosa Rabbit facial nerve anastomosis with fibrin glue: nerve conduction velocity evaluation

    Directory of Open Access Journals (Sweden)

    Francisco Aurelio Lucchesi Sandrini

    2007-04-01

    Full Text Available OBJETIVO: Este estudo tem o objetivo de avaliar através da velocidade de condução nervosa com eletrodos de superfície a utilização da cola de fibrina na anastomose nervosa. MÉTODOS: Neste experimento, foram avaliadas as diferenças entre as velocidades de condução nervosa pré e pós-operatória do nervo facial esquerdo de 12 coelhos. Foi verificada a existência de correlação entre a velocidade de condução nervosa e o número de axônios regenerados no pós-operatório. Os nervos transeccionados foram unidos com cola de fibrina. O potencial de ação motora foi obtido com o uso de eletrodos de superfície. O eletrodo de estimulação foi colocado imediatamente à frente do pavilhão auditivo (tronco do nervo facial e o eletrodo de gravação foi colocado no músculo quadrado do lábio inferior. RESULTADOS: A média normal da velocidade de condução nervosa foi de 36,53 m/seg. Ao final do período, a velocidade de condução nervosa atingiu um valor de aproximadamente 81% do valor normal. Não foi observada correlação significativa entre a velocidade de condução nervosa pós-operatória e o número de axônios regenerados (p=0,146. CONCLUSÃO: A anastomose com cola de fibrina pode ser utilizada para anastomose nervosa no modelo animal e nervo estudados.AIM: The aim of this study was to evaluate the use of fibrin glue on nerve anastomosis, and study conduction velocity obtained by surface electrodes. METHODS: In this experimental model we evaluated nerve conduction velocity differences in the preoperative and postoperative periods, for the left facial nerve of 12 rabbits. Then, we evaluated whether there were correlations between conduction velocity and the number of postoperative regenerated axons. The sectioned nerves were anastomosed with fibrin glue. The muscle action potentials were obtained from surface electrodes. The stimulation electrode was placed immediately before the ear pinna (facial nerve trunk and the recording

  11. Comparative study between fibrin glue and platelet rich plasma in dogs skin grafts Estudo comparativo entre a cola de fibrina e o plasma rico em plaquetas em enxertos cutâneos em cães

    Directory of Open Access Journals (Sweden)

    Larissa Correa Hermeto

    2012-11-01

    Full Text Available PURPOSE: Compare fibrin glue (Tissucol® and platelet-rich plasma in full-thickness mesh skin grafts in dogs. METHODS: Eighteen dogs were used, divided into two groups: fibrin glue (FG and platelet-rich plasma (PRP. In all the animals, a full-thickness 3x3 cm mesh skin graft was implanted. In the left limb, the biomaterial was place between the graft and the receptor bed, according to the group, while the right limb served as the control group. All the animals were evaluated clinically every 48 hours until the 14th day, using the variables of exudation, coloration, edema and cosmetic appearance. Three animals were evaluated histologically, on the third, seventh and tenth postoperative days, using the variables of fibroblasts, collagen, granulation tissue, microscopic integration-adherence and acute inflammation. RESULTS: Clinical evaluations showed that the group CF showed better scores for all variables compared to PRP group. On the histological evaluations PRP group had a higher presence of fibroblasts in the seventh and fourteenth days. CONCLUSION: The fibrin glue group was clinically superior to the platelet-rich group when used on full-thickness skin grafts in dogs.OBJETIVO: Comparar a cola de fibrina (Tissucol® e o plasma rico em plaquetas em enxertos cutâneos de espessura completa em malha em cães. MÉTODOS: Foram utilizados 18 cães, distribuídos em dois grupos, cola de fibrina (CF e plasma rico em plaquetas (PRP. Em todos os animais foi realizado um enxerto cutâneo de 3x3 cm, em malha de espessura completa. No membro esquerdo foi colocado o biomaterial entre o enxerto e o leito receptor, cada qual em seu grupo, o membro direito serviu como grupo controle. Todos os animais foram avaliados clinicamente a cada 48 horas até o décimo quarto dia, através das variáveis: exsudação, coloração, edema e aspecto cosmético; histologicamente em três animais, no terceiro, sétimo e décimo quarto dia de pós-operatório através das

  12. 蛋白胶-罂粟碱复合体促进调Q Nd:YAG激光治疗后创面愈合的观察%Using Fibrin Glue Papaverine Complex to Promote Wounds Healing after Q-Switched Laser

    Institute of Scientific and Technical Information of China (English)

    朱玉; 李栋梁; 陈志勇; 谭强; 周业松

    2011-01-01

    目的 观察蛋白胶-罂粟碱复合体对调Q Nd:YAG激光治疗后创面愈合的促进作用.方法 太田痣患者50例,随机分为研究组和对照组,每组25例.以调Q Nd:YAG激光治疗后,分别应用蛋白胶-罂粟碱复合体或凡士林纱布覆盖创面,对比观察两组患者创面疼痛评分、止血时间及愈合时间.结果 研究组在创面疼痛评分、止血时间、创面愈合时间均优于对照组.结论 蛋白胶-罂粟碱复合体对调Q Nd:YAG激光治疗后的创面具有明显的减轻疼痛,促进愈合的作用.%Objective To observe the effects of using fibrin glue papaverine complex to promote wound healing after Q-switched laser therapy.Methods Fifty patients with nevus of Ota were randomly and equally assigned to two groupa: the study group applied fibrin glue papaverine complex and the control group applied vaseline gauze,and their wounds pain, hemostatic lime and healing time were compared.Results Covering wounds with glue papaverine complex after Q-switched laser was superior to the other therapy from aspects of pain alleviation, hemostatic time and healing time.Conclusions Covering wounds with glue papaverine complex after the treatment of Q-switched laser can alleviate the pain and accelerate the wound healing.

  13. Fixação de enxerto cutâneo em malha de espessura total com sutura ou cola de fibrina Fixation of full-thickness mesh skin using suture or fibrin glue

    Directory of Open Access Journals (Sweden)

    M.S.P. Amaral

    2004-06-01

    Full Text Available Avaliou-se a influência da cola de fibrina, derivada do veneno de serpente, na fixação e integração de enxerto de pele. Foram utilizados nove cães, sem raça definida, com peso médio de 15kg. Foi induzida ferida de 4×4cm de área, na face crânio-proximal dos antebraços direito e esquerdo. Um enxerto de espessura total foi colhido da região torácica e expandido por meio de expansor de pele. No membro direito o enxerto foi estabilizado no leito receptor por meio de pontos isolados simples; no esquerdo foi fixado pela aplicação de cola de fibrina e oito pontos de sutura. O sítio doador foi fechado empregando-se retalho cutâneo bipediculado. As bandagens do leito receptor foram oclusivas e não aderentes e aplicou-se pomada de neomicina com bacitracina. A troca de bandagens ocorreu diariamente até o sétimo dia de pós-operatório e, posteriormente, a cada três dias. A área de sobrevivência do enxerto foi obtida pela subtração das áreas não viáveis e total medidas com fotomicroscópio Nikon conectado a um sistema de análise de imagem KS-300 aos três, sete, 15 e 30 dias de pós-operatório. Para a avaliação microscópica, a área do enxerto foi colhida em três animais aos sete, 15 e 30 dias de pós-operatório. Não houve diferença entre momentos de avaliação e técnicas de fixação quanto à área de enxerto viável. Os enxertos fixados com cola apresentaram estágio de reparação mais avançado em todos os momentos. Concluiu-se que a cola de fibrina derivada do veneno de serpente tem moderado poder adesivo e, pela análise microscópica, favorece a integração do enxerto cutâneo em malha de espessura total.The purpose of this study was to evaluate the efficiency of fibrin glue, derived from snake venom, on fixation and integration of skin graft. Nine crossbred dogs, with average weight of 15kg were used. Wounds measuring 4×4 cm were induced at the cranioproximal aspect of the right and left forelimb. Full

  14. Tratamento de linfocele inguinal pós-operatória com injeção de cola de fibrina: relato de caso Treatment of postoperative inguinal lymphocele with fibrin glue injection: case report

    Directory of Open Access Journals (Sweden)

    Priscila Nunes Boaventura

    2007-06-01

    Full Text Available O paciente desenvolveu linforragia na região inguinal direita, depois de ponte aorto-bifemoral com enxerto de dácron®. Não respondeu ao tratamento conservador com cuidados locais e compressão. Foi realizado exame de ultra-sonografia Doppler, que evidenciou grande linfocele (6,4 x 3,36 x 6,1 cm, tratada pelo esvaziamento da loja por aspiração e injeção de cola de fibrina (1,6 mL em seu interior. O paciente se recuperou sem intercorrências e sem recidiva, após 3 meses de seguimento.The patient developed lymphatic drainage in the right groin after an aortobifemoral bypass with Dacron® graft. Conservative treatment with local wound care and compression was unsuccessful. Duplex scan showed a 6.4 x 3.36 x 6.1 cm lymphocele, which was treated by aspiration and injection of fibrin glue (1.6 mL. The patient recovered uneventfully and without recurrence after a 3-month follow-up.

  15. Data Transport Subsystem - The SFOC glue

    Science.gov (United States)

    Parr, Stephen J.

    1988-01-01

    The design and operation of the Data Transport Subsystem (DTS) for the JPL Space Flight Operation Center (SFOC) are described. The SFOC is the ground data system under development to serve interplanetary space probes; in addition to the DTS, it comprises a ground interface facility, a telemetry-input subsystem, data monitor and display facilities, and a digital TV system. DTS links the other subsystems via an ISO OSI presentation layer and an LAN. Here, particular attention is given to the DTS services and service modes (virtual circuit, datagram, and broadcast), the DTS software architecture, the logical-name server, the role of the integrated AI library, and SFOC as a distributed system.

  16. Stable supergravity dual of nonsupersymmetric glue

    International Nuclear Information System (INIS)

    Babington, James; Crooks, David E.; Evans, Nick

    2003-01-01

    We study nonsupersymmetric fermion mass and condensate deformations of the AdS conformal field theory correspondence. The five dimensional supergravity flows are lifted to a complete and remarkably simple ten dimensional background. A brane probe analysis shows that when all the fermions have an equal mass a positive mass is generated for all six scalar fields leaving nonsupersymmetric Yang-Mills theory in the deep infrared. We numerically determine the potential, produced by the background, in the Schroedinger equation relevant to the study of O ++ glueballs. The potential is a bounded well, providing evidence of stability and for a discrete, confined spectrum. The geometry can also describe the supergravity background around an (unstable) fuzzy 5-brane

  17. 医用OB胶联合几丁聚糖-胶原导管修复兔面神经损伤的实验研究%Facial nerve repair with OB glue and chitosan-collagen conduit:An experimental study in rabbits

    Institute of Scientific and Technical Information of China (English)

    屈振宇; 曲卫国; 马卫东; 曲晓娟; 张璐; 裘罡

    2011-01-01

    PORFUSE: To explore the effect of using OB glue combined with chitosan-collagen conduit to repair rabbit facial nerve injury. METHODS: Thirty Chinese rabbits were divided into 3 groups randomly. The injury in right facial nerve of rabbits was repaired using: nerve autografts (group I ), OB glue (group Ⅱ), and OB glue with chitosan-collagen conduit (group Ⅲ) in 3 groups,respectively. Gross observation, electrophysiological study, histological study and image analysis were performed 16 weeks postoperatively .The data was subjected to one-way ANOVA with SPSS 17.0 software package to evaluate nerve regeneration. RESULTS: Nerve regeneration was obvious observed 16 weeks postoperatively and could resist certain tension . Chitosan-collagen conduit was degraded 16 weeks postoperatively and restrained the formation of neuroma. The tissue adhesions in group I and group Ⅱ was more severe than in group Ⅲ. The recovery of neuro-muscular function was good in 3 groups,and motor nerve action potential was not significantly different among 3 groups (P>0.05),but the compound muscle action potential (CMAP) of regenerated nerve was significantly higher in group Ⅲ than in group Ⅱ (P0.05).Different degree of hyperplasia of fibrous connective tissue and new formed capillaries was noted ,nrnl inflammatory cell infiltration was also found in 3 groups. The effect of chitosan - collagen ennduil in group Ⅲ was observed both under low magnification of microscope and high nullification with Gomori's silver staining.The recovery rale of myelinated fibrr cross section diameler in 3 groups was different (p0.05 ). CONCLUSION: Chitnsan-collagRn conduit has excellent biocompatibilty. It can be OB glue to repair nerves injuries with good results. Supported by Dalian Outstanding Science and Technology Talents Fund (2006J23JH016).%目的:探讨医用OB胶联合几丁聚糖--胶原导管修复兔面神经损伤的效果.方法:30只健康中国大耳白兔随机分为3组,

  18. Influência da gramatura na resistência da linha de cola aos esforços de cisalhamento em painéis compensados de Copaifera duckei Dawyer e Eperua oleifera Ducke Effects of amount of adhesive spread on the glue line shear strength in the plywood of Copaifera duckei Dawyer and Eperua oleifera Ducke

    Directory of Open Access Journals (Sweden)

    Nerci Nina Lima

    2011-03-01

    Full Text Available A madeira por ser um material de origem orgânica responde de várias maneiras aos diversos produtos nela empregados, inclusive a aplicação de cola a qual depende do seu teor de umidade, tendendo a atingir um teor de umidade em equilíbrio dinâmico com a umidade relativa da atmosfera. Atualmente utilizam-se lâminas com teores de umidade entre 5 e 15% de acordo com o tipo de resina utilizada. O presente estudo avaliou o efeito de 04 gramaturas (270; 330; 364 e 390 g/m² na produção de painéis compensados utilizando as espécies: Copaifera duckei Dawyer e Eperua oleifera Ducke. As espécies utilizadas foram retiradas da área de manejo florestal sustentável da Gethal Indústria de Madeira Compensada Ltda localizada em Manicoré-Am. As lâminas foram produzidas com espessuras de 2,2 mm. As variáveis do ciclo de prensagem foram controladas seguindo as orientações técnicas estabelecidas pelo fabricante da resina. Foi avaliada a resistência da linha de cola, com amostras da capa e do miolo em condições seca e pós-fervura. Para análise estatística foi aplicado um delineamento inteiramente casualizado com arranjo em esquema fatorial dos tratamentos. Confrontando os valores médios da tensão de ruptura e a percentagem de falha na madeira obtidos nesta pesquisa, ensaio seco e pós-fervura, com os da literatura, foi verificado que os painéis avaliados atendem aos critérios estabelecidos, podendo ser indicados para uso interior e exterior, pois de acordo com a Norma EN 314-2 (1993 o valor médio da tensão de ruptura em conjunto com a porcentagem de falha na madeira encontram-se em um padrão aceitável de comportamento.The wood as a source of organic material responds in different ways to different treatments her employees, including the application of glue which depends on its moisture content, tending to reach a moisture content in dynamic equilibrium with relative humidity of the atmosphere. Currently we use blades with moisture

  19. O papel do adesivo de fibrina e da sutura na fixação do transplante de menisco preservado por ultracongelamento em coelhos The role of fibrin glue and suture on the fixation of ultra frozen preserved meniscus transplantation in rabbits

    Directory of Open Access Journals (Sweden)

    Leandro José Reckers

    2009-10-01

    Full Text Available OBJETIVO: Avaliar a capacidade do adesivo de fibrina em promover a fixação do menisco ao longo de duas, quatro e oito semanas comparando com a técnica convencional de fixação por sutura a tecidos moles. MÉTODOS: 36 meniscos mediais direitos de coelhos preservados a 73°C negativos por 30 dias foram transplantados para os animais da mesma amostra e fixados com sutura ou cola de fibrina. Após duas, quatro ou oito semanas a aparência dos meniscos e a qualidade da fixação foram verificadas macroscopicamente e avaliadas por um sistema de escores. Os achados foram submetidos a estudo estatístico de análise de variância por postos (p OBJECTIVE: To evaluate the ability of fibrin adhesive in promoting the meniscus fixation within two, four and eight weeks compared to the conventional soft-tissue suture technique. MATERIALS AND METHODS: 36 right medial menisci of rabbits preserved at negative 73° Celsius for 30 days were transplanted to animals of the same sample and fixed with soft-tissue suture or fibrin glue. After 2, 4 or 8 weeks, the appearance of the menisci and the quality of fixation were macroscopically checked and evaluated by a scoring system. The findings were subjected to the statistical study of variance analysis (p < 0.05%. RESULTS: The deep-frozen meniscus preservation maintained the integrity of the meniscus transplant, and, macroscopically, there was no significant reduction of the length of the meniscus in all post-transplant periods (p = 0.015. The menisci fixed with fibrin showed slight changes in color and surface roughness. There were no signs of rejection or infection in both groups. Suture fixation scoring was superior (p = 0.015 in all periods (80% of total fixation as compared to the setting promoted by fibrin (20% of total fixation. CONCLUSION: The homologous transplantation of the meniscus of rabbits experienced various degrees of integration to the knee according to the fixation method; the surgical soft tissues

  20. Electrophysiologic assessment of regeneration in rat sciatic nerve repair using suture, fibrin glue or a combination of both techniques Avaliação eletrofisiológica da eficácia de três tipos de reparo após a secção do nervo ciático do rato

    Directory of Open Access Journals (Sweden)

    Roberto Sergio Martins

    2005-09-01

    Full Text Available We evaluated the repair of seccioned rat sciatic nerve by the comparison of electrophysiologic parameters. The repair was effected with suture (group A, fibrin glue (group B or a combination of both techniques (group C. The amplitude, latency and conduction velocity of the motor and nerve action potentials were assessed before the nerve section and at reoperation after 24 weeks. There was no difference between the groups when the nerve action potential was evaluated. Rats of group B presented better results than those of group A (pForam comparados os parâmetros obtidos na avaliação eletrofisiológica do potencial de ação do nervo e do potencial de ação motor antes e após 24 semanas do reparo no nervo ciático do rato previamente seccionado no lado direito com a utilização de sutura (grupo A, adesivo de fibrina (grupo B ou uma combinação das duas técnicas (grupo C. Não houve diferença entre os grupos na avaliação do potencial de ação do nervo. Quando consideradas a latência e a velocidade de condução mensurados na reoperação e a razão entre a velocidade de condução medida na reoperação e o mesmo parâmetro antes da secção do nervo, durante a mensuração do potencial de ação motor, os animais do grupo B apresentaram melhores resultados em relação aos do grupo A (p<0,05. Os animais do grupo C apresentaram melhores resultados em comparação com os do grupo A quando considerada a razão entre a velocidade de condução medida 24 semanas do reparo e antes da secção do nervo durante a avaliação do potencial de ação motor. Conclui-se que os animais em que o reparo dos nervos foi realizado com o adesivo de fibrina apresentaram melhores resultados em comparação com a sutura quando considerados os parâmetros obtidos na mensuração do potencial de ação motor.

  1. Memory as social glue: Close interpersonal relationships in amnesic patients

    Directory of Open Access Journals (Sweden)

    Patrick S.R. Davidson

    2012-12-01

    Full Text Available Memory may be crucial for establishing and/or maintaining social bonds. Using the National Social life, Health, and Aging Project questionnaire, we examined close interpersonal relationships in three amnesic people: K.C. and D.A. (who are adult-onset cases and H.C. (who has developmental amnesia. All three patients were less involved than demographically-matched controls with neighbors and religious and community groups. A higher-than-normal percentage of the adult-onset (K.C. and D.A. cases’ close relationships were with family members, and they had made few new close friends in the decades since the onset of their amnesia. On the other hand, the patient with developmental amnesia (H.C. had forged a couple of close relationships, including one with her fiancé. Social networks appear to be winnowed, but not obliterated, by amnesia. The obvious explanation for the patients’ reduced social functioning stems from their memory impairment, but we discuss other potentially important factors for future study.

  2. Attention as the 'glue' for object integration in parietal extinction.

    Science.gov (United States)

    Conci, Markus; Groß, Julia; Keller, Ingo; Müller, Hermann J; Finke, Kathrin

    2018-04-01

    Patients with unilateral, parietal brain damage frequently show visual extinction, which manifests in a failure to identify contralesional stimuli when presented simultaneously with other, ipsilesional stimuli (but full awareness for single stimulus presentations). Extinction reflects an impairment of spatial selective attention, leaving basic preattentive processing unaffected. For instance, access to bilaterally grouped objects is usually spared in extinction, suggesting that grouping occurs at a stage preceding (in the patients: abnormally biased) spatial-attentional selection. Here, we reinvestigated this notion by comparing (largely between participants, but also within a single-case participant) conditions with objects that varied in their dominant direction of grouping: from the attended to the non-attended hemifield (data from Conci et al., 2009) versus from the non-attended to the attended hemifield (new data). We observe complete absence of extinction when shape completion extended from the attended hemifield. By contrast, extinction was not diminished when object groupings propagate from the unattended hemifield. Moreover, we found the individual severity of the attentional impairment (assessed by a standard "inattention" test) to be directly related to the degree of completion in the unattended hemifield. This pattern indicates that grouping can overcome visual extinction only when object integration departs from the attended visual field, implying, contrary to many previous accounts, that attention is crucial for grouping to be initiated. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Adhesion of tissue glues to different biological substrates

    NARCIS (Netherlands)

    Bochynska, A. I.; Hannink, G.; Buma, P.; Grijpma, D. W.

    2017-01-01

    Tissue adhesives are attractive materials with potential to replace the use of sutures and staples in the repair of the injured tissues. The research field of tissue adhesives is dynamically growing, and different methods and tissue models are employed to evaluate the adhesive properties of newly

  4. Adhesion of tissue glues to different biological substrates

    NARCIS (Netherlands)

    Bochynska, Agnieszka; Hannink, G.; Buma, P.; Grijpma, Dirk W.

    2016-01-01

    Tissue adhesives are attractive materials with potential to replace the use of sutures and staples in the repair of the injured tissues. The research field of tissue adhesives is dynamically growing, and different methods and tissue models are employed to evaluate the adhesive properties of newly

  5. Spider Silk Glue Proteins BAA 8.1

    Science.gov (United States)

    2017-09-14

    model for each. These genes were all sequenced at the ends to confirm the sequences were correct prior to using them for...protein expression. 3. The genes were then used in flask fermentation expression studies to insure that protein of the correct size was being...one of the lengths (3X, roughly a 140kD protein) for initial studies. We were able to detect protein production in these fermentations but

  6. Memory as Social Glue: Close Interpersonal Relationships in Amnesic Patients

    OpenAIRE

    Davidson, Patrick S. R.; Drouin, Héloïse; Kwan, Donna; Moscovitch, Morris; Rosenbaum, R. Shayna

    2012-01-01

    Memory may be crucial for establishing and/or maintaining social bonds. Using the National Social life, Health, and Aging Project questionnaire, we examined close interpersonal relationships in three amnesic people: K.C. and D.A. (who are adult-onset cases) and H.C. (who has developmental amnesia). All three patients were less involved than demographically matched controls with neighbors and religious and community groups. A higher-than-normal percentage of the adult-onset (K.C. and D.A.) cas...

  7. Movement is the glue connecting home ranges and habitat selection.

    Science.gov (United States)

    Van Moorter, Bram; Rolandsen, Christer M; Basille, Mathieu; Gaillard, Jean-Michel

    2016-01-01

    Animal space use has been studied by focusing either on geographic (e.g. home ranges, species' distribution) or on environmental (e.g. habitat use and selection) space. However, all patterns of space use emerge from individual movements, which are the primary means by which animals change their environment. Individuals increase their use of a given area by adjusting two key movement components: the duration of their visit and/or the frequency of revisits. Thus, in spatially heterogeneous environments, animals exploit known, high-quality resource areas by increasing their residence time (RT) in and/or decreasing their time to return (TtoR) to these areas. We expected that spatial variation in these two movement properties should lead to observed patterns of space use in both geographic and environmental spaces. We derived a set of nine predictions linking spatial distribution of movement properties to emerging space-use patterns. We predicted that, at a given scale, high variation in RT and TtoR among habitats leads to strong habitat selection and that long RT and short TtoR result in a small home range size. We tested these predictions using moose (Alces alces) GPS tracking data. We first modelled the relationship between landscape characteristics and movement properties. Then, we investigated how the spatial distribution of predicted movement properties (i.e. spatial autocorrelation, mean, and variance of RT and TtoR) influences home range size and hierarchical habitat selection. In landscapes with high spatial autocorrelation of RT and TtoR, a high variation in both RT and TtoR occurred in home ranges. As expected, home range location was highly selective in such landscapes (i.e. second-order habitat selection); RT was higher and TtoR lower within the selected home range than outside, and moose home ranges were small. Within home ranges, a higher variation in both RT and TtoR was associated with higher selectivity among habitat types (i.e. third-order habitat selection). Our findings show how patterns of geographic and environmental space use correspond to the two sides of a coin, linked by movement responses of individuals to environmental heterogeneity. By demonstrating the potential to assess the consequences of altering RT or TtoR (e.g. through human disturbance or climatic changes) on home range size and habitat selection, our work sets the basis for new theoretical and methodological advances in movement ecology. © 2015 The Authors. Journal of Animal Ecology © 2015 British Ecological Society.

  8. Percutaneous vertebroplasty set for easier and safer glue injection

    International Nuclear Information System (INIS)

    Gangi, A.; Guth, S.; Roche, A.; Dietemann, J.L.

    2002-01-01

    Purpose: Percutaneous vertebroplasty is used to strengthen the pathologic vertebral body and reduce pain in some diseases involving the spine. The purpose of this study was to evaluate segment stability and clinical status in patients who received vertebroplasty after radiofrequency ablation of spinal tumors. Methods and materials: 23 vertebroplasties with polymethylmethacrylate were performed in 14 patients who had been treated with radiofrequency ablation of inter- or paravertebral tumors in the thoracic and/or lumbar spine. Vertebroplasty was indicated due to presence or imminent tumor related vertebral fractures and presence of imminent neurological deficits. Operations were carried out under CT/fluoroscopy guidance under local anesthesia and on an out-patient basis. At follow-up, preoperative MR images were compared with follow-up MR-images in addition to clinical examination. Follow up ranged from 3 to 12 months. Results: At follow-up, MR images of treated vertebral bodies showed no signs of sintering or refracture. Clinical examination showed improved mobility of the spine in 13 patients (92.9%). In none of these patients was the presence or progression of neurological deficits diagnosed. 1 patient (7.1%) was restricted in motion due to a new tumor in another segment. No intra- or postoperative complications were reported. Conclusion: Our results indicate that image-guided percutaneous vertebroplasty seems to be a safe and effective, minimally invasive method to stabilize pathologic vertebral bodies in patients who have received radiofrequency ablation of spinal tumors

  9. Microneural anastomosis with fibrin glue : an experimental study.

    OpenAIRE

    Suri A; Mehta V; Sarkar C

    2002-01-01

    An experimental study was designed to compare the histological analysis of nerve anastomosis with 10-0 microsurgical sutures and fibrin adhesive. Wistar albino rats′ sciatic nerves were transected and repaired either with fibrin adhesive-Beriplast P (M/s Centeon-Cadila Health Care) or with 10-0 monofilament microsutures. Histological assessment was performed at 10, 20, 30, 60 and 90 days after surgery. Functional recovery of the sciatic nerves started at two months and was near normal ...

  10. Pain as social glue: shared pain increases cooperation.

    Science.gov (United States)

    Bastian, Brock; Jetten, Jolanda; Ferris, Laura J

    2014-11-01

    Even though painful experiences are employed within social rituals across the world, little is known about the social effects of pain. We examined the possibility that painful experiences can promote cooperation within social groups. In Experiments 1 and 2, we induced pain by asking some participants to insert their hands in ice water and to perform leg squats. In Experiment 3, we induced pain by asking some participants to eat a hot chili pepper. Participants performed these tasks in small groups. We found evidence for a causal link: Sharing painful experiences with other people, compared with a no-pain control treatment, promoted trusting interpersonal relationships by increasing perceived bonding among strangers (Experiment 1) and increased cooperation in an economic game (Experiments 2 and 3). Our findings shed light on the social effects of pain, demonstrating that shared pain may be an important trigger for group formation. © The Author(s) 2014.

  11. An icy-glue model of cometary nuclei

    International Nuclear Information System (INIS)

    Gombosi, T.I.; Houpis, H.L.F.

    1986-05-01

    Since 1950 a number of models have been proposed to explain the observations of comets. For the most part the icy conglomerate model of Whipple was the standard. Based on the recent images made by VEGA and GIOTTO spacecrafts of comet Halley, a model of the nucleus is suggested that retains the advantages of the icy conglomerate formalism on a local level, while a new global framework is introduced. The model is disscussed in terms of the mounting knowledge of comets, the creation of the nucleus in the cosmogenic sence, and expectations of future analysis of data and observations are presented. A new methodology for calculating the evolution and thermal profiles of the nucleus is also presented. (author)

  12. THE WOODEN GLUE STRUCTURES OF FOREIGN MODERN PEDESTRIAN BRIDGES

    Directory of Open Access Journals (Sweden)

    E. N. Trach

    2015-02-01

    Full Text Available A brief review on the application of wooden bridges is presented as well as wooden structures of modern pedestrian and road bridges built in recent years in the Western Europe are described. Based upon the review, the conclusions concerning the construction of similar structures in Ukraine are made.

  13. Glue balls, quarks, and the pomeron-f

    International Nuclear Information System (INIS)

    Dash, J.W.

    1978-04-01

    Three issues are presented related to s-channel unitarity which argue in favor of the p-f identity model of diffraction of Chew, Rosenzweig, and Chan, and which argue against the traditional p+f model. These are (1) the violation of two component duality in modern p+f fits, (2) threshold effects due to strangeness, charm, and baryon production (flavoring), and (3) quark-loop renormalization of the QCD glueball, consistent with observed hadron multiplicities and dominant short range order. I also review p-f identity phenomenology

  14. glue protein profiles in the nasuta–albomicans complex

    Indian Academy of Sciences (India)

    . Manasagangotri ... Further, quantitative analysis also shows lack of correlation between the chromosomal ... involving these two races followed by karyotypic screening of hybrid .... The molecular masses of the variable protein fractions were ...

  15. Precision templates for glueing wire holding pieces to chamber frames

    International Nuclear Information System (INIS)

    Berdugo, J.; Burgos, C.; Cerrada, M.

    1995-09-01

    In the present report we describe the procedure which has been used in order to optimize the precision obtained when positioning forward backward muon chamber sensor wire planes of the L3 experiment at CERN. With templates produced at CIEMAT a precision of about 10 microns, in sizes of the order of 3 meters has been achieved

  16. Clinical application of radioaerosol studies - pulmonary embolism, inhalation burns and glue-sniffers and COPD

    International Nuclear Information System (INIS)

    Sundram, Felix

    1994-01-01

    The alveolar epithelium and the capillary endothelium together form the alveolar capillary membrane. Fluid exchange occurs across this membrane, and is dependent on intravascular and interstitial hydrostatic and oncotic pressures, and on permeability of this membrane. Damage to either the alveolar or capillary component can result in a high permeability pulmonary oedema, even though the alveolar epithelium forms an extremely tight membrane which is ten times less permeable than the capillary endothelium. Nuclear medicine methods can be used to observe changes in integrity of pulmonary capillary endothelium (with first pass dual-indicator dilution technique using successive injections of radiotracer), and of alveolar epithelium, and it is important that the damage should be detected before patients develop clinical pulmonary oedema so that intensive therapy can be instituted early. We have used 99m Tc DTPA radioaerosol to measure alteration in pulmonary epithelial permeability and to image the distribution of ventilation in normal and some pathological states. In some clinical studies Tc-99m (tin) colloid radioaerosol has been used to obtain the ventilation images

  17. A New Outlook on Mental Illnesses: Glial Involvement Beyond the Glue

    KAUST Repository

    Elsayed, Maha

    2015-12-16

    Mental illnesses have long been perceived as the exclusive consequence of abnormalities in neuronal functioning. Until recently, the role of glial cells in the pathophysiology of mental diseases has largely been overlooked. However recently, multiple lines of evidence suggest more diverse and significant functions of glia with behavior-altering effects. The newly ascribed roles of astrocytes, oligodendrocytes and microglia have led to their examination in brain pathology and mental illnesses. Indeed, abnormalities in glial function, structure and density have been observed in postmortem brain studies of subjects diagnosed with mental illnesses. In this review, we discuss the newly identified functions of glia and highlight the findings of glial abnormalities in psychiatric disorders. We discuss these preclinical and clinical findings implicating the involvement of glial cells in mental illnesses with the perspective that these cells may represent a new target for treatment.

  18. In search of low cost biological analysis: Wax or acrylic glue bonded paper microfluidic devices

    KAUST Repository

    Kodzius, Rimantas; Gong, Xiuqing; Li, Shunbo; Qin, Jianhua; Wen, Weijia; Wu, Jinbo; Xiao, Kang; Yi, Xin

    2011-01-01

    We report a simple, low-cost and detachable microfluidic chip incorporating easily accessible paper, glass slides or other polymer films as the chip materials along with adhesive wax or cyanoacrylate-based resin as the recycling bonding material. We use a laser to cut through the paper or film to form patterns and then sandwich the paper and film between glass sheets or polymer membranes. The hot-melt adhesive wax or simple cyanoacrylate-based resin can realize bridge bonding between various materials, for example, paper, polymethylmethacrylate film, glass sheets, or metal plate. The wax bonding process is reversible and the wax is reusable through a melting and cooling process. With this process, a three-dimensional (3D) microfluidic chip is achievable by evacuating the channels of adhesive material in a hot-water. We applied the wax-paper based microfluidic chip to HeLa cell electroporation. Subsequently, a prototype of a 5-layer 3D chip was fabricated by multilayer wax bonding. To check the sealing ability and the durability of the chip, green fluorescence protein recombinant E. coli bacteria were cultured, with which the chemotaxis of E. coli was studied in order to determine the influence of antibiotic ciprofloxacin concentration on the E. coli migration. The chip bonded with cyanoacrylate-based resin was tested by measuring protein concentration and carrying out DNA capillary electrophoresis. To study the biocompatibility and applicability of our microfluidic chip fabrication technology, we tested the PCR compatibility of our chip materials along with various other common materials employed in the fabrication of microfluidic chips including: silicon, several kinds of silicon oxide, glasses, plastics, wax, and adhesives, etc. Two-temperature PCR was performed with these materials to determine their PCR-inhibitory effect. In most of the cases, addition of bovine serum albumin effectively improved the reaction yield. We also studied the individual PCR components from the standpoint of adsorption. Most of the materials did not inhibit the DNA, whereas they did show noticeable interaction with the DNA polymerase. This work provides a simple low cost fabrication method for creating microfluidic devices for biological analysis. Example assays were undertaken and the biocompatibility of our technology was studied, both of which demonstrated the utility of our approach.

  19. In search of low cost biological analysis: Wax or acrylic glue bonded paper microfluidic devices

    KAUST Repository

    Kodzius, Rimantas

    2011-11-04

    In this body of work we have been developing and characterizing paper based microfluidic fabrication technologies to produce low cost biological analysis. Specifically we investigated the performance of paper microfluidics that had been bonded using wax o

  20. Bouncers, Brokers, and Glue: The Self-Described Roles of Social Workers in Urban Hospitals

    Science.gov (United States)

    Craig, Shelley L.; Muskat, Barbara

    2013-01-01

    Social workers delivering services in health care settings face unique challenges and opportunities. The purpose of this study was to solicit input from social workers employed in urban hospitals about their perceptions of the roles, contribution, and professional functioning of social work in a rapidly changing health care environment. Using…

  1. DayAND#8211;Care Surgery for Pilonidal Sinus Using Sinotomy Technique and Fibrin Glue Injection

    Directory of Open Access Journals (Sweden)

    Selim Sozen

    2012-06-01

    Conclusion: An ideal surgical procedure for a pilonidal sinus should be one aiming at reducing hospital stay, minimizing tissue assault, promoting early work resumption, and preventing recurrence. The method described in this paper was found to be simple, safe, and feasible as day-care surgery. The technique of sinotomy with a good wound and surrounding skin care is an ideal approach with a high chance of cure. The patients returned to their routine within a short duration of time. [Arch Clin Exp Surg 2012; 1(3.000: 138-141

  2. Glue embolization of the giant aneurysm by reducing thrombosis-induced volume expansion effect

    Energy Technology Data Exchange (ETDEWEB)

    Yeom, Yoo Kyung; Suh, Dae Chul [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2015-04-15

    A giant aneurysm due to a large intra-aneurysmal volume can be complicated by a delayed massive volume expansion caused by thrombus formation. To prevent such a severe mass effect, we obliterated the aneurysmal lumen by gluing and prevented further development of thrombosis. A 52-year-old female with a giant aneurysm at the cavernous segment of the internal carotid artery presented with tinnitus and intermittent diplopia. After confirming with a negative occlusion test, the right internal carotid artery was trapped by coiling and with further obliteration of the aneurysmal lumen by gluing. She developed a mild diplopia after the procedure and recovered without any deficit. The magnetic resonance angiography showed a stable occlusion of the aneurysm and good collateral filling of the cerebral vessel 15 months later.

  3. Glue Generation Framework in Uniframe for the CORBA-Java/RMI Interoperability

    National Research Council Canada - National Science Library

    Tammala, Kalpana

    2004-01-01

    .... The UniFrame approach provides a seamless framework for achieving a DCS by automatic or semi-automatic integration of heterogeneous distributed components white taking into account their QoS (Quality of Service...

  4. Equifinality of formal (DREAM) and informal (GLUE) Bayesian approaches in hydrologic modeling?

    NARCIS (Netherlands)

    Vrugt, J.A.; ter Braak, C.J.F.; Gupta, H.V.; Robinson, B.A.

    2009-01-01

    In recent years, a strong debate has emerged in the hydrologic literature regarding what constitutes an appropriate framework for uncertainty estimation. Particularly, there is strong disagreement whether an uncertainty framework should have its roots within a proper statistical (Bayesian) context,

  5. Bridging the gap between GLUE and formal statistical approaches: approximate Bayesian computation

    NARCIS (Netherlands)

    Sadegh, M.; Vrugt, J.A.

    2013-01-01

    In recent years, a strong debate has emerged in the hydrologic literature regarding how to properly treat nontraditional error residual distributions and quantify parameter and predictive uncertainty. Particularly, there is strong disagreement whether such uncertainty framework should have its roots

  6. Linkage and mapping analyses of the no glue egg gene Ng in the ...

    African Journals Online (AJOL)

    Jane

    2011-08-24

    Aug 24, 2011 ... The Ng gene was mapped at 28.0 of the silkworm classical genetic linkage group 12. (Xiang, 1995). In recent years, molecular biology has made consider- able progress ..... project (08080703017), China agriculture research.

  7. GOODBYE TO PAPER, HIGHLIGHTERS, SCISSORS AND GLUE: INNOVATING THE CONTENT ANALYSIS PROCESS THROUGH ATLAS.TI

    Directory of Open Access Journals (Sweden)

    Silvana Anita Walter

    2015-06-01

    Full Text Available Atlas.ti software comprises a tool for the analysis of qualitative data that can facilitate its management and interpretation. However, the use of this software has been much less frequent in strategy, despite the increasing use of content analysis in this area.This study aimed to demonstrate, through an example, the applicability of Atlas.ti software in conducting thematic content analysis in the strategy area. The example used was a survey conducted on two accounting firms in Curitiba, Paraná (PR, and applied to the firm’s directors, as a data collection instrument, through semi-structured interviews. With the help of Atlas.ti 5.0 software, thematic content analysis was undertaken and brought to light that the two offices have a similar trajectory; they are characterized as family members; they hold or held centralization of power; made innovations; do not have formalized plans; and, most of their strategies are emerging. The example used allowed for the demonstration of: the encoding process; the writing of research notes and comments; the establishment of relationships between the elements analyzed; and, the grouping and management of such elements. It is hoped that this study contributes to stimulating the use of Atlas.ti software and assists in improving the consistency and betterment of qualitative research through the ease of empirical verification.

  8. Theta Phase Synchronization Is the Glue that Binds Human Associative Memory.

    Science.gov (United States)

    Clouter, Andrew; Shapiro, Kimron L; Hanslmayr, Simon

    2017-10-23

    Episodic memories are information-rich, often multisensory events that rely on binding different elements [1]. The elements that will constitute a memory episode are processed in specialized but distinct brain modules. The binding of these elements is most likely mediated by fast-acting long-term potentiation (LTP), which relies on the precise timing of neural activity [2]. Theta oscillations in the hippocampus orchestrate such timing as demonstrated by animal studies in vitro [3, 4] and in vivo [5, 6], suggesting a causal role of theta activity for the formation of complex memory episodes, but direct evidence from humans is missing. Here, we show that human episodic memory formation depends on phase synchrony between different sensory cortices at the theta frequency. By modulating the luminance of visual stimuli and the amplitude of auditory stimuli, we directly manipulated the degree of phase synchrony between visual and auditory cortices. Memory for sound-movie associations was significantly better when the stimuli were presented in phase compared to out of phase. This effect was specific to theta (4 Hz) and did not occur in slower (1.7 Hz) or faster (10.5 Hz) frequencies. These findings provide the first direct evidence that episodic memory formation in humans relies on a theta-specific synchronization mechanism. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. The Sticky Subject of Religion: Can It Ever be the Glue for a Stable Society?

    Science.gov (United States)

    2011-12-01

    understandable, two notable scholars from very different perspectives, Jean -Jacques Rousseau (1712–1778) and later Emile Durkheim (1858–1917), questioned...affairs‖ setting the stage for politics to come (Long & Reich, 1980, p. 323). Essentially, Israel inherited a millet system which granted religious

  10. In search of low cost biological analysis: Wax or acrylic glue bonded paper microfluidic devices

    KAUST Repository

    Kodzius, Rimantas

    2011-01-01

    In this body of work we have been developing and characterizing paper based microfluidic fabrication technologies to produce low cost biological analysis. Specifically we investigated the performance of paper microfluidics that had been bonded using wax o

  11. RuO₂ pH Sensor with Super-Glue-Inspired Reference Electrode.

    Science.gov (United States)

    Lonsdale, Wade; Wajrak, Magdalena; Alameh, Kamal

    2017-09-06

    A pH-sensitive RuO₂ electrode coated in a commercial cyanoacrylate adhesive typically exhibits very low pH sensitivity, and could be paired with a RuO₂ working electrode as a differential type pH sensor. However, such sensors display poor performance in real sample matrices. A pH sensor employing a RuO₂ pH-sensitive working electrode and a SiO₂-PVB junction-modified RuO₂ reference electrode is developed as an alternative high-performance solution. This sensor exhibits a performance similar to that of a commercial glass pH sensor in some common sample matrices, particularly, an excellent pH sensitivity of 55.7 mV/pH, a hysteresis as low as 2.7 mV, and a drift below 2.2 mV/h. The developed sensor structure opens the way towards the development of a simple, cost effective, and robust pH sensor for pH analysis in various sample matrices.

  12. The glue-clot technique: a new technique description for small calyceal stone fragments removal

    NARCIS (Netherlands)

    Cloutier, J.; Cordeiro, E. R.; Kamphuis, G. M.; Villa, L.; Letendre, J.; de la Rosette, J. J.; Traxer, Olivier

    2014-01-01

    During the last 20 years, the technology advancement of small flexible ureterorenoscopes has dramatically changed the management of renal calculi. Retrograde intrarenal surgery (RIRS) has currently a high impact on active stone treatment, and it is increasingly used worldwide. Nevertheless, kidney

  13. Extensible Synthetic File Servers? or: Structuring the Glue between Tester and System Under Test

    NARCIS (Netherlands)

    Belinfante, Axel; Mullender, Sape J.; Collyer, G.

    2007-01-01

    We discuss a few simple scenarios of how we can design and develop a compositional synthetic ��?le server that gives access to external processes – in particular, in the context of testing, gives access to the system under test – such that certain parts of said synthethic ��?le server can be

  14. Sac Angiography and Glue Embolization in Emergency Endovascular Aneurysm Repair for Ruptured Abdominal Aortic Aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Koike, Yuya, E-mail: r06118@hotmail.co.jp; Nishimura, Jun-ichi, E-mail: jun-ichi-n@nifty.com; Hase, Soichiro, E-mail: haseman@hotmail.co.jp; Yamasaki, Motoshige, E-mail: genyamasaki@gmail.com [Kawasaki Saiwai Hospital, Department of Interventional Radiology (Japan)

    2015-04-15

    PurposeThe purpose of this study was to demonstrate a sac angiography technique and evaluate the feasibility of N-butyl cyanoacrylate (NBCA) embolization of the ruptured abdominal aortic aneurysm (AAA) sac in emergency endovascular aneurysm repair (EVAR) in hemodynamically unstable patients.MethodsA retrospective case series of three patients in whom sac angiography was performed during emergency EVAR for ruptured AAA was reviewed. After stent graft deployment, angiography within the sac of aneurysm (sac angiography) was performed by manually injecting 10 ml of contrast material through a catheter to identify the presence and site of active bleeding. In two patients, sac angiography revealed active extravasation of the contrast material, and NBCA embolization with a coaxial catheter system was performed to achieve prompt sealing.ResultsSac angiography was successful in all three patients. In the two patients who underwent NBCA embolization for aneurysm sac bleeding, follow-up computed tomography (CT) images demonstrated the accumulation of NBCA consistent with the bleeding site in preprocedural CT images.ConclusionsEVAR is associated with a potential risk of ongoing bleeding from type II or IV endoleaks into the disrupted aneurysm sac in patients with severe coagulopathy. Therefore, sac angiography and NBCA embolization during emergency EVAR may represent a possible technical improvement in the treatment of ruptured AAA in hemodynamically unstable patients.

  15. Embolization of Cyanoacrylate glue in systemic circulation in a case of hepatocellular carcinoma: an autopsy report

    Directory of Open Access Journals (Sweden)

    Kochhar Rakesh K

    2009-12-01

    Full Text Available Abstract We report a case of embolism of the sclerosant dye with subsequent formation of foreign-body giant cell reaction within the veins of pulmonary and portal circulation in an autopsy case of hepatocellular carcinoma developing over an underlying primary biliary cirrhosis.

  16. RuO2 pH Sensor with Super-Glue-Inspired Reference Electrode

    Directory of Open Access Journals (Sweden)

    Wade Lonsdale

    2017-09-01

    Full Text Available A pH-sensitive RuO2 electrode coated in a commercial cyanoacrylate adhesive typically exhibits very low pH sensitivity, and could be paired with a RuO2 working electrode as a differential type pH sensor. However, such sensors display poor performance in real sample matrices. A pH sensor employing a RuO2 pH-sensitive working electrode and a SiO2-PVB junction-modified RuO2 reference electrode is developed as an alternative high-performance solution. This sensor exhibits a performance similar to that of a commercial glass pH sensor in some common sample matrices, particularly, an excellent pH sensitivity of 55.7 mV/pH, a hysteresis as low as 2.7 mV, and a drift below 2.2 mV/h. The developed sensor structure opens the way towards the development of a simple, cost effective, and robust pH sensor for pH analysis in various sample matrices.

  17. RuO2 pH Sensor with Super-Glue-Inspired Reference Electrode

    OpenAIRE

    Lonsdale, Wade; Wajrak, Magdalena; Alameh, Kamal

    2017-01-01

    A pH-sensitive RuO2 electrode coated in a commercial cyanoacrylate adhesive typically exhibits very low pH sensitivity, and could be paired with a RuO2 working electrode as a differential type pH sensor. However, such sensors display poor performance in real sample matrices. A pH sensor employing a RuO2 pH-sensitive working electrode and a SiO2-PVB junction-modified RuO2 reference electrode is developed as an alternative high-performance solution. This sensor exhibits a performance similar to...

  18. RuO2 pH Sensor with Super-Glue-Inspired Reference Electrode

    Science.gov (United States)

    Wajrak, Magdalena; Alameh, Kamal

    2017-01-01

    A pH-sensitive RuO2 electrode coated in a commercial cyanoacrylate adhesive typically exhibits very low pH sensitivity, and could be paired with a RuO2 working electrode as a differential type pH sensor. However, such sensors display poor performance in real sample matrices. A pH sensor employing a RuO2 pH-sensitive working electrode and a SiO2-PVB junction-modified RuO2 reference electrode is developed as an alternative high-performance solution. This sensor exhibits a performance similar to that of a commercial glass pH sensor in some common sample matrices, particularly, an excellent pH sensitivity of 55.7 mV/pH, a hysteresis as low as 2.7 mV, and a drift below 2.2 mV/h. The developed sensor structure opens the way towards the development of a simple, cost effective, and robust pH sensor for pH analysis in various sample matrices. PMID:28878182

  19. Electrodes as social glue: measuring heart rate promotes giving in the trust game.

    Science.gov (United States)

    Van Lange, Paul A M; Finkenauer, Catrin; Popma, Arne; van Vugt, Mark

    2011-06-01

    While physiological measures are increasingly used to help us understand the workings of interpersonal trust (and related behaviors), we know very little about the effects of such measures on trust. We examined the effects of a classic measure, the measurement of heart rate using a standard protocol, on behavioral trust in dyads of women who did not know each other. Behavioral trust was assessed in the trust game, in which the trustor decides how much money from their subject payment to give to a trustee, while knowing that the experimenter triples that amount before giving it to the trustee, after which the trustee decides how much money to return to the trustor. As predicted, we found greater levels of behavioral trust in the trust game, as well as greater returns by the trustees (which were accounted for by trustor's giving), in the heart rate (HR) than in no heart rate (NHR) measurement condition. Parallel findings were observed for self-reported trust. Findings are discussed in terms of the idea that the elusive effects of a protocol for measuring heart rate can cause pronounced effects on subsequent social interactions via enhanced interpersonal trust. 2011 Elsevier B.V. All rights reserved.

  20. Electrodes as social glue: Measuring heart rate promotes giving in the trust game

    NARCIS (Netherlands)

    van Lange, P.A.M.; Finkenauer, C.; Popma, A.; van Vugt, M.

    2011-01-01

    While physiological measures are increasingly used to help us understand the workings of interpersonal trust (and related behaviors), we know very little about the effects of such measures on trust. We examined the effects of a classic measure, the measurement of heart rate using a standard

  1. Comparison of synthetic glues and 10-0 nylon in rabbit lamellar keratoplasty.

    Science.gov (United States)

    Cho, Soon Young; Kim, Man Soo; Oh, Su Ja; Chung, Sung Kun

    2013-09-01

    To evaluate changes in mean keratometry and to compare wound repair with corneal lamellar grafts in rabbit eyes using human synthetic tissue adhesives and 10-0 nylon. Corneal grafts were made using a 6.0-mm-diameter trephine and blades in the eyes of 15 New Zealand white rabbits. Human fibrin tissue adhesive (Tisseel) was used in group 1, human fibrin tissue adhesive (Beriplast P) was used in group 2, polyethylene glycol adhesive (Coseal) was used in group 3, and 8 bite sutures with 10-0 nylon were used in group 4 (control) for lamellar keratoplasty. Four bite sutures were made with 10-0 nylon in groups 1, 2, and 3. Slit-lamp microscopy and keratometry were performed at 3 days and 1, 2, and 4 weeks after the surgery. Histopathologic and electromicroscopic examinations were performed 4 weeks after the surgery. No inflammation or corneal toxicity was seen in groups 1 and 2. Histologically, a few inflammatory cells were seen in groups 3 and 4. Groups 1, 2, and 3 showed no statistically significant changes in mean keratometry at 4 weeks postoperatively compared with preoperative mean keratometry (Wilcoxon signed-rank test, P = 0.178, 0.208, and 0.889, respectively). The control group showed significant changes in mean keratometry at 4 weeks postoperatively (Wilcoxon signed-rank test, P = 0.018). Human fibrin tissue adhesives were well tolerated in rabbit eyes, with no apparent corneal toxicity. Polyethylene glycol adhesive showed more inflammation and insufficient wound repair compared with human fibrin tissue adhesives. Therefore, human fibrin tissue adhesives can be used as an alternative to sutures in lamellar keratoplasty.

  2. Composition of fibrin glues significantly influences axial vascularization and degradation in isolation chamber model.

    Science.gov (United States)

    Arkudas, Andreas; Pryymachuk, Galyna; Hoereth, Tobias; Beier, Justus P; Polykandriotis, Elias; Bleiziffer, Oliver; Gulle, Heinz; Horch, Raymund E; Kneser, Ulrich

    2012-07-01

    In this study, different fibrin sealants with varying concentrations of the fibrin components were evaluated in terms of matrix degradation and vascularization in the arteriovenous loop (AVL) model of the rat. An AVL was placed in a Teflon isolation chamber filled with 500 μl fibrin gel. The matrix was composed of commercially available fibrin gels, namely Beriplast (Behring GmbH, Marburg, Germany) (group A), Evicel (Omrix Biopharmaceuticals S.A., Somerville, New Jersey, USA) (group B), Tisseel VH S/D (Baxter, Vienna, Austria) with a thrombin concentration of 4 IU/ml and a fibrinogen concentration of 80 mg/ml [Tisseel S F80 (Baxter), group C] and with an fibrinogen concentration of 20 mg/ml [Tisseel S F20 (Baxter), group D]. After 2 and 4 weeks, five constructs per group and time point were investigated using micro-computed tomography, and histological and morphometrical analysis techniques. The aprotinin, factor XIII and thrombin concentration did not affect the degree of clot degradation. An inverse relationship was found between fibrin matrix degradation and sprouting of blood vessels. By reducing the fibrinogen concentration in group D, a significantly decreased construct weight and an increased generation of vascularized connective tissue were detected. There was an inverse relationship between matrix degradation and vascularization detectable. Fibrinogen as the major matrix component showed a significant impact on the matrix properties. Alteration of fibrin gel properties might optimize formation of blood vessels.

  3. Activating "Invisible" Glue: Using Electron Beam for Enhancement of Interfacial Properties of Graphene-Metal Contact.

    Science.gov (United States)

    Kim, Songkil; Russell, Michael; Kulkarni, Dhaval D; Henry, Mathias; Kim, Steve; Naik, Rajesh R; Voevodin, Andrey A; Jang, Seung Soon; Tsukruk, Vladimir V; Fedorov, Andrei G

    2016-01-26

    Interfacial contact of two-dimensional graphene with three-dimensional metal electrodes is crucial to engineering high-performance graphene-based nanodevices with superior performance. Here, we report on the development of a rapid "nanowelding" method for enhancing properties of interface to graphene buried under metal electrodes using a focused electron beam induced deposition (FEBID). High energy electron irradiation activates two-dimensional graphene structure by generation of structural defects at the interface to metal contacts with subsequent strong bonding via FEBID of an atomically thin graphitic interlayer formed by low energy secondary electron-assisted dissociation of entrapped hydrocarbon contaminants. Comprehensive investigation is conducted to demonstrate formation of the FEBID graphitic interlayer and its impact on contact properties of graphene devices achieved via strong electromechanical coupling at graphene-metal interfaces. Reduction of the device electrical resistance by ∼50% at a Dirac point and by ∼30% at the gate voltage far from the Dirac point is obtained with concurrent improvement in thermomechanical reliability of the contact interface. Importantly, the process is rapid and has an excellent insertion potential into a conventional fabrication workflow of graphene-based nanodevices through single-step postprocessing modification of interfacial properties at the buried heterogeneous contact.

  4. A New Outlook on Mental Illnesses: Glial Involvement Beyond the Glue

    KAUST Repository

    Elsayed, Maha; Magistretti, Pierre J.

    2015-01-01

    Mental illnesses have long been perceived as the exclusive consequence of abnormalities in neuronal functioning. Until recently, the role of glial cells in the pathophysiology of mental diseases has largely been overlooked. However recently, multiple lines of evidence suggest more diverse and significant functions of glia with behavior-altering effects. The newly ascribed roles of astrocytes, oligodendrocytes and microglia have led to their examination in brain pathology and mental illnesses. Indeed, abnormalities in glial function, structure and density have been observed in postmortem brain studies of subjects diagnosed with mental illnesses. In this review, we discuss the newly identified functions of glia and highlight the findings of glial abnormalities in psychiatric disorders. We discuss these preclinical and clinical findings implicating the involvement of glial cells in mental illnesses with the perspective that these cells may represent a new target for treatment.

  5. Capillary condensation in atomic scale friction: how water acts like a glue.

    Science.gov (United States)

    Jinesh, K B; Frenken, J W M

    2006-04-28

    We present atomic-scale friction force measurements that strongly suggest that the capillary condensation of water between a tungsten tip and a graphite surface leads to the formation of ice at room temperature. This phenomenon increases the friction force, introduces a short-term memory in the form of an elastic response against shearing, and allows us to "write" a temporary line of ice on a hydrophobic surface. Rearrangements of the condensate are shown to take place on a surprisingly slow time scale of seconds.

  6. Society, Land, Love or Money (A Strategic Model of How to Glue the Generations Together),

    Science.gov (United States)

    1981-01-01

    carrying of extra capital stock. 33 REFERENCES Dawkins , R. (1976), The Selfish Gene . New York: Oxford University Press. Dubey, P. and N. Shubik (1981...a gene would rapidly disappear. The care for offspring needs to be forthcoming until the last of the new generation is selfsufficient and able to...payoff than the firs:. it is more complicated. 20 4.3. Selfish Individuals and Threat Strategies (Model 1) In this section an example is fully

  7. A GLUE uncertainty analysis of a drying model of pharmaceutical granules

    DEFF Research Database (Denmark)

    Mortier, Séverine Thérèse F.C.; Van Hoey, Stijn; Cierkens, Katrijn

    2013-01-01

    unit, which is part of the full continuous from-powder-to-tablet manufacturing line (Consigma™, GEA Pharma Systems). A validated model describing the drying behaviour of a single pharmaceutical granule in two consecutive phases is used. First of all, the effect of the assumptions at the particle level...... on the prediction uncertainty is assessed. Secondly, the paper focuses on the influence of the most sensitive parameters in the model. Finally, a combined analysis (particle level plus most sensitive parameters) is performed and discussed. To propagate the uncertainty originating from the parameter uncertainty...

  8. Inorganic Glue Enabling High Performance of Silicon Particles as Lithium Ion Battery Anode

    KAUST Repository

    Cui, Li-Feng; Hu, Liangbing; Wu, Hui; Choi, Jang Wook; Cui, Yi

    2011-01-01

    overcome the pulverization problem, however these nano-engineered silicon anodes usually involve very expensive processes and have difficulty being applied in commercial lithium ion batteries. In this study, we report a novel method using amorphous silicon

  9. Joint hypermobility and headache: the glue that binds the two together--part 2.

    Science.gov (United States)

    Martin, Vincent T; Neilson, Derek

    2014-09-01

    Past studies have reported that connective tissue disorders (CTDs) are more common in patients with specific types of headache disorders. The objectives of this study are (1) to review and critique the clinical studies reporting an association between joint hypermobility, CTDs and headache and (2) to postulate mechanisms though which CTDs might predispose to headache disorders. PubMed was searched for relevant articles with search terms that included joint hypermobility, Ehlers-Danlos syndrome, Marfan syndrome, and specific headache disorders. A narrative review was performed of these articles as well as those identified from the bibliography of these articles. Case reports and case control studies confirm an association between CTDs and migraine, coat-hanger headaches, carotid arterial dissections, intracranial hypotension, Arnold Chiari malformations-type 1, cervical spine disorders, and temporomandibular joint disorders. Observational cross-sectional studies suggest that the prevalence of CTDs is increased in patients with specific types of headache disorders. It is unknown if the CTDs directly cause these headaches disorders or are associated with them through other mechanisms. © 2014 American Headache Society.

  10. Electron Ion Collider: The Next QCD Frontier - Understanding the glue that binds us all

    CERN Document Server

    Accardi, A.; Anselmino, M.; Armesto, N.; Aschenauer, E.C.; Bacchetta, A.; Boer, D.; Brooks, W.K.; Burton, T.; Chang, N.B.; Deng, W.T.; Deshpande, A.; Diehl, M.; Dumitru, A.; Dupré, R.; Ent, R.; Fazio, S.; Gao, H.; Guzey, V.; Hakobyan, H.; Hao, Y.; Hasch, D.; Holt, R.; Horn, T.; Huang, M.; Hutton, A.; Hyde, C.; Jalilian-Marian, J.; Klein, S.; Kopeliovich, B.; Kovchegov, Y.; Kumar, K.; Kumerički, K.; Lamont, M.A.C.; Lappi, T.; Lee, J.H.; Lee, Y.; Levin, E.M.; Lin, F.L.; Litvinenko, V.; Ludlam, T.W.; Marquet, C.; Meziani, Z.E.; McKeown, R.; Metz, A.; Milner, R.; Morozov, V.S.; Mueller, A.H.; Müller, B.; Müller, Dieter; Nadel-Turonski, P.; Paukkunen, H.; Prokudin, A.; Ptitsyn, V.; Qian, X.; Qiu, J.W.; Ramsey-Musolf, M.; Roser, T.; Sabatié, F.; Sassot, R.; Schnell, G.; Schweitzer, P.; Sichtermann, E.; Stratmann, M.; Strikman, M.; Sullivan, M.; Taneja, S.; Toll, T.; Trbojevic, D.; Ullrich, T.; Venugopalan, R.; Vigdor, S.; Vogelsang, W.; Weiss, C.; Xiao, B.W.; Yuan, F.; Zhang, Y.H.; Zheng, L.

    2016-01-01

    This White Paper presents the science case of an Electron-Ion Collider (EIC), focused on the structure and interactions of gluon-dominated matter, with the intent to articulate it to the broader nuclear science community. It was commissioned by the managements of Brookhaven National Laboratory (BNL) and Thomas Jefferson National Accelerator Facility (JLab) with the objective of presenting a summary of scientific opportunities and goals of the EIC as a follow-up to the 2007 NSAC Long Range plan. This document is a culmination of a community-wide effort in nuclear science following a series of workshops on EIC physics and, in particular, the focused ten-week program on "Gluons and quark sea at high energies" at the Institute for Nuclear Theory in Fall 2010. It contains a brief description of a few golden physics measurements along with accelerator and detector concepts required to achieve them, and it benefited from inputs from the users' communities of BNL and JLab. This White Paper offers the promise to prope...

  11. Electron-Ion Collider: The next QCD frontier. Understanding the glue that binds us all

    Energy Technology Data Exchange (ETDEWEB)

    Accardi, A. [Hampton University, Hampton, VA (United States); Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Albacete, J.L. [Universite Paris-Sud 11, CNRS/IN2P3, IPNO, Orsay (France); Anselmino, M. [Torino University (Italy); INFN, Torino (Italy); Armesto, N. [University of Santiago de Campostela, Santiago de Compostela (Spain); Aschenauer, E.C.; Burton, T.; Fazio, S.; Hao, Y.; Lamont, M.A.C.; Lee, J.H.; Lee, Y.; Litvinenko, V.; Ludlam, T.W.; Ptitsyn, V.; Qiu, J.W.; Roser, T.; Toll, T.; Trbojevic, D.; Ullrich, T.; Venugopalan, R.; Vigdor, S. [Brookhaven National Laboratory, Upton, NY (United States); Bacchetta, A. [University of Pavia, Pavia (Italy); Boer, D. [University of Groningen, Groningen (Netherlands); Brooks, W.K.; Hakobyan, H.; Kopeliovich, B. [Universidad Tecnica Federico Santa Maria, Valparaiso (Chile); Chang, N.B.; Huang, M. [Shandong University, Shandong (China); Deng, W.T. [Frankfurt University, FIAS, Frankfurt (Germany); Shandong University, Shandong (China); Deshpande, A.; Kumar, K. [Stony Brook University, Stony Brook, NY (United States); Diehl, M. [DESY, Hamburg (Germany); Dumitru, A.; Jalilian-Marian, J. [Baruch College, CUNY, New York, NY (United States); Dupre, R.; Sabatie, F. [Centre de Saclay, CEA, Gif-sur-Yvette (France); Ent, R.; Guzey, V.; Hutton, A.; Lin, F.L.; McKeown, R.; Morozov, V.S.; Nadel-Turonski, P.; Prokudin, A.; Weiss, C.; Zhang, Y.H. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Gao, H. [Duke University, Durham, NC (United States); Hasch, D. [INFN, LNF, Frascati (Italy); Holt, R. [Argonne National Laboratory, Argonne, IL (United States); Horn, T. [The Catholic University of America, N.E. Washington, DC (United States); Hyde, C. [Old Dominion University, Norfolk, VA (United States); Klein, S.; Sichtermann, E.; Yuan, F. [Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Kovchegov, Y. [The Ohio State University, Columbus, OH (United States); Kumericki, K. [University of Zagreb, Zagreb (Croatia); Lappi, T.; Paukkunen, H. [University of Jyvaskyla, Jyvaskyla (Finland); Levin, E.M. [Tel Aviv University, Tel Aviv (Israel); Universidad Tecnica Federico Santa Maria, Valparaiso (Chile); Marquet, C. [CERN, Geneva (Switzerland); Meziani, Z.E.; Metz, A. [Temple University, Philadelphia, PA (United States); Milner, R. [Massachusetts Institute of Technology, Cambridge, MA (United States); Mueller, A.H. [Columbia University, New York, NY (US); Mueller, B. [Brookhaven National Laboratory, Upton, NY (US); Duke University, Durham, NC (US); Mueller, D. [Ruhr-University Bochum, Bochum (DE); Qian, X. [California Institute of Technology, Pasadena, CA (US); Ramsey-Musolf, M. [University of Massachusetts at Amherst, Amherst, MA (US); Sassot, R. [University of Buenos Aires, Buenos Aires (AR); Schnell, G. [University of Basque Country, Bilbao (ES); Schweitzer, P. [University of Connecticut, Storrs, CT (US); Stratmann, M.; Vogelsang, W. [University of Tuebingen, Tuebingen (DE); Strikman, M. [Pennsylvania State University, Philadelphia, PA (US); Sullivan, M. [Stanford Linear Accelerator Center, Menlo Park, CA (US); Taneja, S. [Dalhousie University, Halifax, Nova Scotia (CA); Stony Brook University, Stony Brook, NY (US); Xiao, B.W. [Central China Normal University, Wuhan, Hubei (CN); Zheng, L. [Brookhaven National Laboratory, Upton, NY (US); Central China Normal University, Wuhan, Hubei (CN)

    2016-09-15

    This White Paper presents the science case of an Electron-Ion Collider (EIC), focused on the structure and interactions of gluon-dominated matter, with the intent to articulate it to the broader nuclear science community. It was commissioned by the managements of Brookhaven National Laboratory (BNL) and Thomas Jefferson National Accelerator Facility (JLab) with the objective of presenting a summary of scientific opportunities and goals of the EIC as a follow-up to the 2007 NSAC Long Range plan. This document is a culmination of a community-wide effort in nuclear science following a series of workshops on EIC physics over the past decades and, in particular, the focused ten-week program on ''Gluons and quark sea at high energies'' at the Institute for Nuclear Theory in Fall 2010. It contains a brief description of a few golden physics measurements along with accelerator and detector concepts required to achieve them. It has been benefited profoundly from inputs by the users' communities of BNL and JLab. This White Paper offers the promise to propel the QCD science program in the US, established with the CEBAF accelerator at JLab and the RHIC collider at BNL, to the next QCD frontier. (orig.)

  12. DNA Photo Lithography with Cinnamate-based Photo-Bio-Nano-Glue

    Science.gov (United States)

    Feng, Lang; Li, Minfeng; Romulus, Joy; Sha, Ruojie; Royer, John; Wu, Kun-Ta; Xu, Qin; Seeman, Nadrian; Weck, Marcus; Chaikin, Paul

    2013-03-01

    We present a technique to make patterned functional surfaces, using a cinnamate photo cross-linker and photolithography. We have designed and modified a complementary set of single DNA strands to incorporate a pair of opposing cinnamate molecules. On exposure to 360nm UV, the cinnamate makes a highly specific covalent bond permanently linking only the complementary strands containing the cinnamates. We have studied this specific and efficient crosslinking with cinnamate-containing DNA in solution and on particles. UV addressability allows us to pattern surfaces functionally. The entire surface is coated with a DNA sequence A incorporating cinnamate. DNA strands A'B with one end containing a complementary cinnamated sequence A' attached to another sequence B, are then hybridized to the surface. UV photolithography is used to bind the A'B strand in a specific pattern. The system is heated and the unbound DNA is washed away. The pattern is then observed by thermo-reversibly hybridizing either fluorescently dyed B' strands complementary to B, or colloids coated with B' strands. Our techniques can be used to reversibly and/or permanently bind, via DNA linkers, an assortment of molecules, proteins and nanostructures. Potential applications range from advanced self-assembly, such as templated self-replication schemes recently reported, to designed physical and chemical patterns, to high-resolution multi-functional DNA surfaces for genetic detection or DNA computing.

  13. Glue embolization of the giant aneurysm by reducing thrombosis-induced volume expansion effect

    International Nuclear Information System (INIS)

    Yeom, Yoo Kyung; Suh, Dae Chul

    2015-01-01

    A giant aneurysm due to a large intra-aneurysmal volume can be complicated by a delayed massive volume expansion caused by thrombus formation. To prevent such a severe mass effect, we obliterated the aneurysmal lumen by gluing and prevented further development of thrombosis. A 52-year-old female with a giant aneurysm at the cavernous segment of the internal carotid artery presented with tinnitus and intermittent diplopia. After confirming with a negative occlusion test, the right internal carotid artery was trapped by coiling and with further obliteration of the aneurysmal lumen by gluing. She developed a mild diplopia after the procedure and recovered without any deficit. The magnetic resonance angiography showed a stable occlusion of the aneurysm and good collateral filling of the cerebral vessel 15 months later.

  14. Ultrasound-Guided Glue Injection as Alternative Treatment of Femoral Pseudoaneurysms

    International Nuclear Information System (INIS)

    Aytekin, Cueneyt; Firat, Ali; Yildirim, Erkan; Kirbas, Ismail; Boyvat, Fatih

    2004-01-01

    The interventional angiographic techniques using the percutaneous femoral approach for endovascular revascularization are becoming increasingly more popular. These methods usually require larger sheaths, and most patients need postprocedural anticoagulation or antiplatelet therapy. As a consequence, the interventional procedure is associated with a higher rate of complications at the arterial entry site compared to diagnostic angiography. The reported incidence of iatrogenic pseudoaneurysm formation after coronary artery interventions ranges from 3.2% to 7.7%, and the rates noted after diagnostic angiography range from 0.2% to 1%. Peripheral pseudoaneurysms have traditionally been treated by surgical intervention, but nonsurgical alternatives, such as ultrasound (US)-guided compression, coil embolization, stent-graft placement, and percutaneous thrombin injection with or without balloon occlusion have also been documented. Of these alternatives, direct percutaneous embolization with embolic agents is the most popular method. The tissue adhesive n-butyl cyanoacrylate (NBCA) (Hystoacryl) (B. Braun, Melsungen, Germany) is one of the most popular occluding agents for neurovascular interventions, and has been widely used for more than 20 years [5,6]. In this study, we evaluated the efficacy and utility of direct percutaneous injection of NBCA for embolization of femoral pseudoaneurysms

  15. The glue that holds the community together? Sport and sustainability in rural Australia

    NARCIS (Netherlands)

    Spaaij, R.

    2009-01-01

    Drawing on the author's research in northwest Victoria, Australia, this essay examines the forms of capital that are created in and through rural sport as well as the processes of social inclusion and exclusion that structure access to social networks and to the resources these networks contain. In

  16. Cervi cornus Colla (deer antler glue) induce epidermal differentiation in the reconstruction of skin equivalents.

    Science.gov (United States)

    Choi, H-R; Nam, K-M; Kim, D-S; Huh, C-H; Na, J-I; Park, K-C

    2013-06-01

    In the reconstruction of skin equivalents (SEs), keratinocyte differentiation is important because epidermal differentiation is closely related with barrier function. The aim of this study was to investigate the effects of Cervi cornus Colla (CCC) on the stem cell activity and epidermal differentiation in the reconstruction of skin equivalent. Four different models were constructed according to different composition of dermal substitute. Results showed similar morphologic findings when hyaluronic acid (HA) and/or CCC was added. But, immunohistochemical staining showed that p63 was significantly increased by addition of HA and/or CCC. Increased staining of integrin α6 and β1 was variably observed when HA and/or CCC was added to make dermal substitute. These finding showed that addition of HA and/or CCC may affect the stem cell activity in the reconstruction of skin. Furthermore, filaggrin expression was much increased when CCC was added. It showed that epidermal differentiation was significantly improved by addition of CCC. In conclusion, simultaneous presence of HA and CCC contributed to the stem cell activity and epidermal differentiation in the reconstruction of SE. Legislation in the EU prohibits marketing cosmetics and personal care products that contain constituents that have been examined through animal experiments. To avoid these limitations, SEs can be used for testing the safety or the efficacy of cosmetic ingredients. Therefore, our results showed that combined use of HA and CCC can be helpful for the reconstruction of SE with good stem cell activity and epidermal differentiation. © 2013 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  17. Bayes' theorem : A negative example of a RCT on grommets in children with glue ear

    NARCIS (Netherlands)

    Rovers, MM; van der Wilt, GJ; van der Bij, S; Straatman, H; Ingels, K; Zielhuis, GA

    Bayesian inference presupposes that practitioners' belief in the effectiveness of medical intervention is the product of prior belief and recent evidence from studies. Although increasingly used, up to now the posterior belief calculated according to the theorem has not been compared with an

  18. Silver (I) as DNA glue: Ag+-mediated guanine pairing revealed by removing Watson-Crick constraints

    Science.gov (United States)

    Swasey, Steven M.; Leal, Leonardo Espinosa; Lopez-Acevedo, Olga; Pavlovich, James; Gwinn, Elisabeth G.

    2015-01-01

    Metal ion interactions with DNA have far-reaching implications in biochemistry and DNA nanotechnology. Ag+ is uniquely interesting because it binds exclusively to the bases rather than the backbone of DNA, without the toxicity of Hg2+. In contrast to prior studies of Ag+ incorporation into double-stranded DNA, we remove the constraints of Watson-Crick pairing by focusing on homo-base DNA oligomers of the canonical bases. High resolution electro-spray ionization mass spectrometry reveals an unanticipated Ag+-mediated pairing of guanine homo-base strands, with higher stability than canonical guanine-cytosine pairing. By exploring unrestricted binding geometries, quantum chemical calculations find that Ag+ bridges between non-canonical sites on guanine bases. Circular dichroism spectroscopy shows that the Ag+-mediated structuring of guanine homobase strands persists to at least 90 °C under conditions for which canonical guanine-cytosine duplexes melt below 20 °C. These findings are promising for DNA nanotechnology and metal-ion based biomedical science. PMID:25973536

  19. Silver (I) as DNA glue: Ag(+)-mediated guanine pairing revealed by removing Watson-Crick constraints.

    Science.gov (United States)

    Swasey, Steven M; Leal, Leonardo Espinosa; Lopez-Acevedo, Olga; Pavlovich, James; Gwinn, Elisabeth G

    2015-05-14

    Metal ion interactions with DNA have far-reaching implications in biochemistry and DNA nanotechnology. Ag(+) is uniquely interesting because it binds exclusively to the bases rather than the backbone of DNA, without the toxicity of Hg(2+). In contrast to prior studies of Ag(+) incorporation into double-stranded DNA, we remove the constraints of Watson-Crick pairing by focusing on homo-base DNA oligomers of the canonical bases. High resolution electro-spray ionization mass spectrometry reveals an unanticipated Ag(+)-mediated pairing of guanine homo-base strands, with higher stability than canonical guanine-cytosine pairing. By exploring unrestricted binding geometries, quantum chemical calculations find that Ag(+) bridges between non-canonical sites on guanine bases. Circular dichroism spectroscopy shows that the Ag(+)-mediated structuring of guanine homobase strands persists to at least 90 °C under conditions for which canonical guanine-cytosine duplexes melt below 20 °C. These findings are promising for DNA nanotechnology and metal-ion based biomedical science.

  20. Relational Ruin or Social Glue? The Joint Effect of Relationship Type and Gossip Valence on Liking, Trust, and Expertise.

    Science.gov (United States)

    Turner, Monique Mitchell; Mazur, Michelle A.; Wendel, Nicole; Winslow, Robert

    2003-01-01

    Explores gossip's function as a social influence tool. Considers if gossip is untrustworthy, leading to relational demise, or whether gossip can lead to perceived liking, trust, and expertise. Indicates that for the undergraduate student subjects, both positive and negative gossip are perceived negatively for both friends and strangers. (SG)

  1. Organic Nano-Grains in Comet 103P/Hartley 2: The Organic Glue of Porous Aggregate Grains?

    Science.gov (United States)

    Wooden, D. H.; Russo, N.Dello; Li, A.; Woodward, C. E.; Kelley, M. S.; Harker, D. E.; Cook, J. C.; Vervack, R. J.; Geballe, T. R.

    2013-01-01

    The GNIRS instrument on the Gemini 8-­-m telescope observed comet 103P/Hartley on 2010-­- Dec-­-04UT, a month after the EPOXI Mission encounter, and detected the 3.3 and 3.4 um bands in emission. The 3.3/3.4 ratio and the broad band widths are consistent with experiments of heated (approximately 600 K) aliphatic carbon (-CH3, -CH2) thin films. For the 3.4 micron band to be in emission, the aliphatic bonds must be attached to a carrier possessing the strongly UV-­-absorbing C=C aromatic rings, and these rings have to be less than 50-­-100 carbon atoms (4-6 Angstrom) for attached -CH bonds to also generate a 3.3 micron-band in emission. Slightly larger (=10Å) Very Small Grains (VSGs) can absorb single UV photons comparable to or exceeding their heat capacity, thermally fluctuate and release IR photon(s). The 3.3 micron and 3.4 micron bands observed by GNIRS suggest that organic macromolecules/ nano-­-grains with both aliphatic and aromatic bonds are fluorescing/thermally fluctuating in the coma. Aliphatic and aromatic materials have been seen in Stardust samples and the primitive carbonaceous chondrite 'Tagish Lake'. The larger the ratio of the -CH2/-CH3 components of the aliphatic 3.4 micron band, the more 'primitive' the organic material. In a Stardust organic globule, some aliphatic bonds were transformed into aromatic bonds during the low dosage of Transmission Electron Microscope imaging. Conversely, lab experiments show irradiation of ices containing small PAHs generates aliphatic organics. Photo-­-processing of ices also likely forms the ubiquitous aliphatic coatings that appear on the surfaces of all silicate subgrains constituting nine cometary interplanetary dust particles. The aliphatic coatings, dominated by -CH2, likely were important in sticking the aggregates together, and existed prior to incorporation of dust aggregates into comet nuclei. These comet aliphatics may be some of the sought-­-after precursors to the more robust and complex organics studied as Insoluble Organic Matter in carbonaceous chondrites. Aliphatic coatings on submicron grains, however, will not be observable in absorption because they are fairly transparent, nor do the aliphatic carbonaceous coatings produce the 3.4 micron emission band because the particles they are attached to are too large (too many vibration modes). We must probe the nano-­-sized organic carriers that undergo substantive thermal fluctuations in cometary comae and emit at 3.3 3.4 micron. Observations of the 3.3 and 3.4 micron emission features contribute to characterizing the evolution of organics prior to their incorporation into cometary nuclei as well as their rapid evolution in cometary comae, which in turn contributes to deepening our understanding of the evolution of organics on the surfaces of asteroids and outer icy bodies in our solar system. Studying organics in comets contributes to understanding the formation and evolution pathways of ISM organics through to the formation of the robust insoluble organic matter in meteorites. A'Hearn, M.F., et al. 2011, Science, 332, 1396; Bockelee-­-Morvan, D. et al. 1995, Icarus, 116, 18; De Gregorio, B.T., et al. 2010, GCA, 74, 4454; Dello Russo, N., et al. 2011, ApJ, 734, L8; Dischler et al. 1983, Solid State Communications, 48, 105; Flynn, G., et al. 2010a, LPSC, 41, #1079; Flynn, G., et al. 2010b, COSPAR, 38, F31-­-0012-­-10; Flynn, G., Wirick, S. 2011, LPSC, 42, #1856; Fomenkova, et al. 1994, GCA 58, 4503; Matrajt, G., et al. 2013, ApJ, 765, 145; Schutte, et al. 1993, ApJ, 415, 397; Wooden, D.H. et al. 2011, EPSC-­-DPS, 1557; Wooden, D.H. et al. 2013, submitted.

  2. USING OF COMBINED TREATMENT BETWEEN PROPOLIS (BEE GLUE) AND GAMMA RADIATION FOR EXTENDING SHELF-LIFE OF CHICKEN BURGER

    International Nuclear Information System (INIS)

    MATTAR, Z.A.; ABDELDAIEM, M.H.

    2008-01-01

    This investigation was carried out to extend the shelf-life of chicken burger using ethanol extract of propolis (EEP) at different concentrations (1 and 2%) as individual treatment using gamma irradiation at doses of 1.5, 3 and 4.5 kGy as individual treatment and combined treatments. The untreated and treated samples of chicken burger were divided into three groups, the first was control, the second group was chicken burger samples treated with 1% EEP then irradiated at doses of 1.5, 3 and 4.5 kGy and the third group was chicken burger samples treated with 2 % EEP then irradiated at doses of 1.5, 3 and 4.5 kGy. The effects of these treatments on the microbiological, chemical and sensory characteristics of chicken burger samples were studied post-treatment and during cold storage (4±1 0 C). The results showed that concentrations of EEP at 1 and 2% reduced the total bacterial count, lactic acid bacteria, Enterobacteriaceae total mold and yeast count, Staphylococcus aureus, Enterococccus faecalis and Bacillus cereus, and the growth of Salmonella spp, was not detected in all treated samples. Also, shelf-life periods were increased up to 27 days for chicken burger treated by 2% EEP and gamma radiation at dose of 4.5 kGy and these combined treatment were more effective as antimicrobial, consequently may be useful as natural food preservative

  3. Identify function methyl cellulose glue of rehabilitation and activation in preparation Tissues used in restoration paper works

    Directory of Open Access Journals (Sweden)

    kobra dadmohammadi

    2017-08-01

    Full Text Available This article aims to facilitate the use of methyl cellulose adhesive to repair paper works that its ink is sensitive to water. This research is conducted by analytical comparisons method and samples is collected by experiments related to research topics such as pH measurement, Calorimetric, infrared spectroscopy with total attenuated reflection (FTIR- ATR, the measurement of tensile strength as well measurement of The adhesive strength of the samples. The stages of this study is conducted so that the adhesive methyl cellulose at a concentration of 7% in methanol was prepared. The prepared specimens is treated under Temperature-humidity accelerated aging in accordance with standard ASTM D4714-96 no for 384 hours and under light in accordance with ASTM D6789-02 for 360 hours and Changes of color, pH, tensile strength and adhesion is investigated for them. Results showed that the samples pH is changed from 6.91 to 6.39 after light aging and to 6.06 after temperature-humidity aging. Also, Tensile strength of Samples is reduced from 0.31 to 0.23 kN per meter after light aging and to 0.24 kN per meter after the temperature-humidity aging. Also, the adhesive strength of the samples is decreased from 1.43 to 0.97 Newton after light aging and to 1.51 Newton after temperature-humidity aging.

  4. High Performance Liquid Chromatography Determination of Urinary Hippuric Acid and Benzoic Acid as Indices for Glue Sniffer Urine

    OpenAIRE

    Abdul Rahim Yacob; Mohamad Raizul Zinalibdin

    2010-01-01

    A simple method for the simultaneous determination of hippuric acid and benzoic acid in urine using reversed-phase high performance liquid chromatography was described. Chromatography was performed on a Nova-Pak C18 (3.9 x 150 mm) column with a mobile phase of mixed solution methanol: water: acetic acid (20:80:0.2) and UV detection at 254 nm. The calibration curve was linear within concentration range at 0.125 to 6.0 mg/ml of hippuric acid and benzoic acid. The recovery, ...

  5. Silver (I) as DNA glue: Ag+-mediated guanine pairing revealed by removing Watson-Crick constraints

    Science.gov (United States)

    Swasey, Steven M.; Leal, Leonardo Espinosa; Lopez-Acevedo, Olga; Pavlovich, James; Gwinn, Elisabeth G.

    2015-05-01

    Metal ion interactions with DNA have far-reaching implications in biochemistry and DNA nanotechnology. Ag+ is uniquely interesting because it binds exclusively to the bases rather than the backbone of DNA, without the toxicity of Hg2+. In contrast to prior studies of Ag+ incorporation into double-stranded DNA, we remove the constraints of Watson-Crick pairing by focusing on homo-base DNA oligomers of the canonical bases. High resolution electro-spray ionization mass spectrometry reveals an unanticipated Ag+-mediated pairing of guanine homo-base strands, with higher stability than canonical guanine-cytosine pairing. By exploring unrestricted binding geometries, quantum chemical calculations find that Ag+ bridges between non-canonical sites on guanine bases. Circular dichroism spectroscopy shows that the Ag+-mediated structuring of guanine homobase strands persists to at least 90 °C under conditions for which canonical guanine-cytosine duplexes melt below 20 °C. These findings are promising for DNA nanotechnology and metal-ion based biomedical science.

  6. Unusual nanosized associates of carboxy-calix[4]resorcinarene and cetylpyridinium chloride: the macrocycle as a glue for surfactant micelles.

    Science.gov (United States)

    Morozova, Ju E; Syakaev, V V; Shalaeva, Ya V; Ermakova, A M; Nizameev, I R; Kadirov, M K; Voloshina, A D; Zobov, V V; Antipin, I S; Konovalov, A I

    2017-03-08

    The association of cetylpyridinium chloride (CPC) micelles in the presence of octaacetated tetraphenyleneoxymethylcalix[4]resorcinarene (CR) leads to the formation of unusual spherical supramolecular nanoparticles (SNPs). Within the range of CR/CPC molar ratios from 10/1 to 1/10 (except for 1/8), CR, acting as a counterion, decreases the critical micelle concentration of CPC by one order of magnitude and leads to the formation of SNPs with an average hydrodynamic radius of 164 nm and an average zeta potential of -60 mV. The formation of SNPs was studied by NMR FT-PGSE and 2D NOESY, DLS, TEM, fluorimetry, and UV-Vis methods. The stability of SNPs at different temperatures and pH values and in the presence of electrolytes was investigated. The specificity of the interactions of the SNPs with substrates that were preferentially bound by a macrocycle or CPC micelle was studied. The enhancement of cation dye binding in the presence of SNPs is shown. The presented supramolecular system may serve as a nanocapsule for water-soluble and water-insoluble compounds.

  7. Transforming a Simple Commercial Glue into Highly Robust Superhydrophobic Surfaces via Aerosol-Assisted Chemical Vapor Deposition.

    Science.gov (United States)

    Zhuang, Aoyun; Liao, Ruijin; Lu, Yao; Dixon, Sebastian C; Jiamprasertboon, Arreerat; Chen, Faze; Sathasivam, Sanjayan; Parkin, Ivan P; Carmalt, Claire J

    2017-12-06

    Robust superhydrophobic surfaces were synthesized as composites of the widely commercially available adhesives epoxy resin (EP) and polydimethylsiloxane (PDMS). The EP layer provided a strongly adhered micro/nanoscale structure on the substrates, while the PDMS was used as a post-treatment to lower the surface energy. In this study, the depositions of EP films were taken at a range of temperatures, deposition times, and substrates via aerosol-assisted chemical vapor deposition (AACVD). A novel dynamic deposition temperature approach was developed to create multiple-layered periodic micro/nanostructures that significantly improved the surface mechanical durability. Water droplet contact angles (CA) of 160° were observed with droplet sliding angles (SA) frequently UV testing (365 nm, 3.7 mW/cm 2 , 120 h) were carried out to exhibit the environmental stability of the films. Self-cleaning behavior was demonstrated in clearing the surfaces of various contaminating powders and aqueous dyes. This facile and flexible method for fabricating highly durable superhydrophobic polymer films points to a promising future for AACVD in their scalable and low-cost production.

  8. Oral seal using glue: a new method to distinguish between intestinal and dermal uptake of metals in earthworms.

    NARCIS (Netherlands)

    Vijver, M.G.; Vink, J.P.M.; Miermans, C.J.H.; van Gestel, C.A.M.

    2003-01-01

    Earthworms may take up chemicals from soil and pore water, both through their skin (dermal) and by ingestion (oral). It remains unclear, however, what the relative importance of these pathways is. To assess bioavailability of pollutants in soil to earthworms, it is necessary that the contribution of

  9. Structures-of-the-Whole: Is There Any Glue to Hold the Concrete-Operational "Stage" Together?

    Science.gov (United States)

    Brainerd, Charles J.

    Studies concerned with the synchronous emergence prediction of Piaget's structures-of-the-whole principle are discussed in conjunction with three groups of concrete-operational skills: (1) transitivity/conservation/class inclusion; (2) double classification/double seriation; and (3) ordinal, cardinal, and natural number concepts. Findings show…

  10. Reduction of Dacarbazine cytogenetic effects on somatic cells in male mice using bee glue (Propolis) to manifest the scientific miracles in the Quran.

    Science.gov (United States)

    Kurdi, Lina Abdul-Fattah; Aljeddani, Fatimah Aliyan

    2016-09-01

    This study was carried out to investigate the ability of Propolis to ameliorate the adverse cytogenetic effects of Dacarbazine on bone marrow cells. In this experimental in vivo study, 18 mice were used, divided into four groups: control group; Propolis-treated group (treated with 50mg/kg Propolis); and Dacarbazine-treated group (treated with 3.5mg/kg Dacarbazine). The fourth, fifth, and sixth were treated with Dacarbazine and Propolis as pre 2h, post 2h, and concomitant treatment. After five days, the Bone Marrow (BM) samples were obtained for cytogenetic investigation. The in vivo studies revealed that Dacarbazine induced an abnormalities in polychromatic erythrocytes cells (PECs) as increase of cell with micronuclei, while the dual treatment accompanied with improvement of this abnormalities. It could be concluded that there are protective effects of Propolis against the adverse effects of Dacarbazine. It could be recommended to use Propolis as an adjuvant with chemotherapeutic agents.

  11. Fixation of split-thickness skin graft using fast-clotting fibrin glue containing undiluted high-concentration thrombin or sutures: a comparison study.

    Science.gov (United States)

    Han, Hyun Ho; Jun, Daiwon; Moon, Suk-Ho; Kang, In Sook; Kim, Min Cheol

    2016-01-01

    For skin defects caused by full-thickness burns, trauma, or tumor tissue excision, skin grafting is one of the most convenient and useful treatment methods. In this situation, graft fixation is important in skin grafting. This study was performed to compare the effectiveness of skin graft fixation between high-concentration fibrin sealant and sutures. There have been numerous studies using fibrin sealant for graft fixation, but they utilized slow-clotting fibrin sealant containing less than 10 IU/mL thrombin. Twenty-five patients underwent split-thickness skin grafting using fast-clotting fibrin sealant containing 400 IU/mL thrombin, while 30 patients underwent grafting using sutures. Rates of hematoma/seroma formation, graft dislocation, graft necrosis, and graft take were investigated postoperatively. The graft surface area was calculated using Image J software (National Institutes of Health, Bethesda, MD, USA). After 5 days, rates of hematoma/seroma formation and graft dislocation were 7.84 and 1.29% in group I, and 9.55 and 1.45% in group II, respectively. After 30 days, rates of graft necrosis and graft take were 1.86 and 98.14% in group I, and 4.65 and 95.35% in group II. Undiluted fibrin sealant showed significantly superior results for all rates ( p  < 0.05) except graft dislocation. When high-concentration fast-clotting fibrin sealant was applied to skin grafts without dilution, no difficulty was experienced during surgery. Sealant showed superior results compared with sutures and had an excellent graft take rate. II.

  12. Rural geriatric glue: a nurse practitioner-led model of care for enhancing primary care for frail older adults within an ecosystem approach.

    Science.gov (United States)

    Prasad, Sadhana; Dunn, Wendy; Hillier, Loretta M; McAiney, Carrie A; Warren, Rex; Rutherford, Paul

    2014-09-01

    This article describes the implementation of the Care for Seniors model of care, an innovative approach to improving care coordination and integration, and provides preliminary evidence of effective use of specialist resources and acute care services. Retrospective. Primary care; cross-sector. Older adults living in a rural area in southwestern Ontario, Canada. Number of new geriatrician referrals and follow-up visits before and after the launch of the Care for Seniors program, number of Nurse Practitioner visits in a primary care setting, in-home, retirement home and hospital, number of discharges home from hospital and length of hospital stay between. In the 2 years before the launch of the program, the total number of visits to the geriatrician for individuals from this FHT was relatively low, 21 and 15, respectively for 2005-06 and 2006-07, increasing to 73 for the 2011-12 year. Although the absolute number of individuals supported by the NP-Geri has remained relatively the same, the numbers seen in the primary care office or in the senior's clinic has declined over time, and the number of home visits has increased, as have visits in the retirement homes. The percentage of individuals discharged home increased from 19% in 2008-09 to 31% in 2009-10 and 26% in 2011-12 and the average length of stay decreased over time. This model of care represents a promising collaboration between primary care and specialist care for improving care to frail older adults living in rural communities, potentially improving timely access to health care and crisis intervention. © 2014, Copyright the Authors Journal compilation © 2014, The American Geriatrics Society.

  13. "Bio-glues" to Enhance Slipperiness of Mucins: Improved Lubricity and Wear Resistance of Porcine Gastric Mucin (PGM) Layers Assisted by Mucoadhesion with Chitosan

    DEFF Research Database (Denmark)

    Nikogeorgos, Nikolaos; Efler, Petr; Lee, Seunghwan

    2015-01-01

    A synergetic lubricating effect between porcine gastric mucin (PGM) and chitosan based on their mucoadhesive interaction is reported at a hydrophobic interface comprised of self-mated polydimethylsiloxane (PDMS) surfaces. In acidic solution (pH 3.2) and low concentrations (0.1 mg mL- 1), the inte......A synergetic lubricating effect between porcine gastric mucin (PGM) and chitosan based on their mucoadhesive interaction is reported at a hydrophobic interface comprised of self-mated polydimethylsiloxane (PDMS) surfaces. In acidic solution (pH 3.2) and low concentrations (0.1 mg mL- 1......), the interaction of PGM with chitosan led to surface recharge and size shrinkage of their aggregates. This resulted in higher mass adsorption on the PDMS surface with increasing weight ratio of [chitosan]/[PGM + chitosan] up to 0.50. While neither PGM nor chitosan exhibited slippery characteristics, coefficient...... of friction being close to 1, their mixture improved considerably the lubricating efficiency (coefficient of friction 0.011 at optimum mixing ratio) and wear resistance of the adsorbed layers. These findings are explained by the role of chitosan as a physical crosslinker within the adsorbed PGM layers...

  14. Uncultured marrow mononuclear cells delivered within fibrin glue hydrogels to porous scaffolds enhance bone regeneration within critical-sized rat cranial defects.

    NARCIS (Netherlands)

    Kretlow, J.D.; Spicer, P.P.; Jansen, J.A.; Vacanti, C.A.; Kasper, F.K.; Mikos, A.G.

    2010-01-01

    For bone tissue engineering, the benefits of incorporating mesenchymal stem cells (MSCs) into porous scaffolds are well established. There is, however, little consensus on the effects of or need for MSC handling ex vivo. Culture and expansion of MSCs adds length and cost, and likely increases risk

  15. Fabrication and Performance of a Glue-Pressed Engineered Honeycomb Bamboo (GPEHB Structure with Finger-jointed Ends as a Potential Substitute for Wood Lumber

    Directory of Open Access Journals (Sweden)

    Jianbo Zhou

    2015-04-01

    Full Text Available With the increasing scarcity of wood as a natural resource, bamboo has become a popular substitute for wood. The present work developed a high-strength original state multi-reorganization material (GPEHB, without the use of a hot press or traditional assembly. The original bamboo units were polygonized into outer contours and milled into finger-joints on each ending. The GPEHB was organized and assembled under an external press, using industrial adhesives. The mechanical properties and thermal insulation of GPEHB were characterized. Moreover, the overall GPEHB unit bending strength was 73.15 MPa, and the parallel-to-grain compression was 55.22 MPa (higher than that of Pinus sylvestris lumber, though less than that of glued laminated bamboo. The GPEHB unit overall density was 0.24 g/cm³, 76% lower than that of glued laminated bamboo, and 50% lower than Pinus sylvestris lumber. The compressive strength of GPEHB (7 units was 170.5 kN, while the compressive strength of GPEHB for 14 units was 493.5 kN, which meet the requirements of GB 50005 (2003. The bending strength of GPEHB 7 units was 12 kN, while that of 14 units was 37 kN. The heat conductivity coefficient for GPEHB was 0.25 W/mK, which is better than concrete and steel. The GPEHB has taken full advantage of its honeycomb-structured material, which allows it to avoid stress concentration in the regular polygonal corners.

  16. Three-dimensional computer reconstruction of large tissue volumes based on composing series of high-resolution confocal images by GlueMRC and LinkMRC software

    Czech Academy of Sciences Publication Activity Database

    Karen, Petr; Jirkovská, M.; Tomori, Z.; Demjénová, E.; Janáček, Jiří; Kubínová, Lucie

    2003-01-01

    Roč. 62, č. 5 (2003), s. 415-422 ISSN 1059-910X R&D Projects: GA ČR GA304/01/0257 Grant - others:VEGA(SK) 2/1146/21; CZ-SK GA MŠk(CZ) KONTAKT 126/184 Institutional research plan: CEZ:AV0Z5011922 Keywords : 3D reconstruction * confocal microscopy * image processing Subject RIV: JC - Computer Hardware ; Software Impact factor: 2.307, year: 2003

  17. Alternative glues for the production of ATLAS silicon strip modules for the Phase-II upgrade of the ATLAS Inner Detector

    OpenAIRE

    Poley, Luise; Bloch, Ingo; Edwards, Sam; Friedrich, Conrad; Gregor, Ingrid-Maria; Jones, Tim; Lacker, Heiko; Pyatt, Simon; Rehnisch, Laura; Sperlich, Dennis; Wilson, John

    2015-01-01

    The Phase-II upgrade of the ATLAS detector for the High Luminosity Large Hadron Collider (HL-LHC) includes the replacement of the current Inner Detector with an all-silicon tracker consisting of pixel and strip detectors. The current Phase-II detector layout requires the construction of 20,000 strip detector modules consisting of sensor, circuit boards and readout chips, which are connected mechanically using adhesives. The adhesive between readout chips and circuit board is a silver epoxy gl...

  18. Trade-offs between seed and leaf size (seed-phytomer-leaf theory): functional glue linking regenerative with life history strategies … and taxonomy with ecology?

    Science.gov (United States)

    Hodgson, John G; Santini, Bianca A; Montserrat Marti, Gabriel; Royo Pla, Ferran; Jones, Glynis; Bogaard, Amy; Charles, Mike; Font, Xavier; Ater, Mohammed; Taleb, Abdelkader; Poschlod, Peter; Hmimsa, Younes; Palmer, Carol; Wilson, Peter J; Band, Stuart R; Styring, Amy; Diffey, Charlotte; Green, Laura; Nitsch, Erika; Stroud, Elizabeth; Romo-Díez, Angel; de Torres Espuny, Lluis; Warham, Gemma

    2017-11-10

    While the 'worldwide leaf economics spectrum' (Wright IJ, Reich PB, Westoby M, et al. 2004. The worldwide leaf economics spectrum. Nature : 821-827) defines mineral nutrient relationships in plants, no unifying functional consensus links size attributes. Here, the focus is upon leaf size, a much-studied plant trait that scales positively with habitat quality and components of plant size. The objective is to show that this wide range of relationships is explicable in terms of a seed-phytomer-leaf (SPL) theoretical model defining leaf size in terms of trade-offs involving the size, growth rate and number of the building blocks (phytomers) of which the young shoot is constructed. Functional data for 2400+ species and English and Spanish vegetation surveys were used to explore interrelationships between leaf area, leaf width, canopy height, seed mass and leaf dry matter content (LDMC). Leaf area was a consistent function of canopy height, LDMC and seed mass. Additionally, size traits are partially uncoupled. First, broad laminas help confer competitive exclusion while morphologically large leaves can, through dissection, be functionally small. Secondly, leaf size scales positively with plant size but many of the largest-leaved species are of medium height with basally supported leaves. Thirdly, photosynthetic stems may represent a functionally viable alternative to 'small seeds + large leaves' in disturbed, fertile habitats and 'large seeds + small leaves' in infertile ones. Although key elements defining the juvenile growth phase remain unmeasured, our results broadly support SPL theory in that phytometer and leaf size are a product of the size of the initial shoot meristem (≅ seed mass) and the duration and quality of juvenile growth. These allometrically constrained traits combine to confer ecological specialization on individual species. Equally, they appear conservatively expressed within major taxa. Thus, 'evolutionary canalization' sensu Stebbins (Stebbins GL. 1974. Flowering plants: evolution above the species level . Cambridge, MA: Belknap Press) is perhaps associated with both seed and leaf development, and major taxa appear routinely specialized with respect to ecologically important size-related traits. © The Author 2017. Published by Oxford University Press on behalf of the Annals of Botany Company. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  19. ATLAS TileCal Sub-Module Production at UIUC - Production Submodule Photos (current)

    CERN Multimedia

    Errede, Steve

    2000-01-01

    Step 4: Stacking and Gluing. Photo 6 - This is the glue robot, it is what we use to stack and glue the modules. Photo 7 - This is the computer progam we use to make the glue dots precise on the spacers and plates. Photo 8 - The Glue Robot in action. .

  20. Prevalence and predictors of illicit drug use among school-going ...

    African Journals Online (AJOL)

    % females) reported having ever used marijuana or glue. ... Conclusions: Public health intervention aimed to prevent marijuana or glue use among adolescents should be designed with the understanding that illicit drug use may be associated ...

  1. Recipes and Techniques for Producing Artist's Materials.

    Science.gov (United States)

    School Arts, 1979

    1979-01-01

    Instructions are given for making oil ground, glue gesso, glue water size, oil colors, damar varnish, water colors, encaustic painting, egg tempera painting, etching inks, etching grounds, etching acids, and sugar-lift. (SJL)

  2. Sticking power from soya beans : higher fossil fuel prices and concerns over formaldehyde in existing glue formulations have led to a resurgence in interest in soya-based adhesives, report

    Science.gov (United States)

    James Wescott; Charles Frihart

    2011-01-01

    Soya beans have long been considered a miracle crop for their ease of growing; high concentration of vegetable oil and high protein content; and their ability to reintroduce nitrogen back into the soil. The origin of soya beans dates back to the early 11th century from the eastern half of China. They were introduced to Europe in 1712 and first...

  3. Vigas mistas de madeira de reflorestamento e bambu laminado colado: análise teórica e experimental Composite beams of reforestation wood and glue-laminated bamboo: theoretical and experimental analyses

    Directory of Open Access Journals (Sweden)

    Humberto C. Lima Júnior

    2001-12-01

    Full Text Available Neste trabalho, apresenta-se e se discute a análise teórica e experimental de vigas de madeira, reforçadas com bambu. Para tanto, o comportamento mecânico de cinco vigas mistas e duas de madeira foi estudado. A parte interna das vigas mistas foi constituída de Pinus elliottii e o reforço de bambu Dendrocalamus giganteus; este reforço foi disposto tanto na parte inferior como na superior das vigas, além de analisadas diferentes espessuras de reforço. São apresentadas curvas carga vs. deslocamentos e carga vs. deformação. Observou-se aumento da ordem de 50% na rigidez das vigas de Pinus elliottii, quando da presença do reforço de bambu. Finalmente, um estudo numérico em que se utilizou o método dos elementos finitos é apresentado, observando-se boa correlação entre os valores numéricos e experimentais.This paper presents and discusses the experimental and theoretical analyses of layer composite beams of wood strengthened with bamboo. For this, the mechanical behavior of five composite beams and two wood beams was studied. The beam's stuffing was composed of Pinus elliottii and the reinforcement of bamboo Dendrocalamus giganteus. The bamboo reinforcement was placed on the top and at the bottom of the beams. Different thicknesses of reinforcement were investigated. Curves of load vs. displacement and load vs. strain are presented. An increase of 50% was observed in the stiffness, when the composite beams are compared with the wood one. Finally, a numerical study was carried out applying the finite element method and a good agreement was observed between the theoretical and experimental values.

  4. A retrospective study of a new n-butyl-2-cyanoacrylate glue ablation catheter incorporated with application guiding light for the treatment of venous insufficiency: Twelve-month results.

    Science.gov (United States)

    Yavuz, Turhan; Acar, Altay Nihat; Aydın, Huseyin; Ekingen, Evren

    2018-01-01

    Objective This study aims to present the early results of a retrospective study of the use of novel n-butyl-2-cyanoacrylate (VenaBlock)-based nontumescent endovenous ablation with a guiding light for the treatment of patients with varicose veins. Methods Patients with lower limb venous insufficiency were treated with n-butyl-2-cyanoacrylate (VenaBlock Venous Closure System) between April 2016 and July 2016. The study enrolled adults aged 21-70 years with symptomatic moderate to severe varicosities (C2-C4b) and great saphenous vein reflux lasting longer than 0.5 s with great saphenous vein diameter between 5.5 and 15 mm assessed in the standing position. No compression stockings were used after the procedure. Duplex ultrasound imaging and clinical follow-up were performed on the third day, first month, sixth month, and 12th month. Clinical, etiological, anatomical, pathophysiological classification; venous clinical severity score; and completed Aberdeen varicose vein questionnaire were recorded. Results Five hundred thirty-eight patients with great saphenous vein incompetency underwent n-butyl-2-cyanoacrylate ablation. The mean ablation length was 25.69 ± 4.8 cm, and the average amount of n-butyl-2-cyanoacrylate delivered was 0.87 ± 0.15 ml. The mean procedure time was 11.7 ± 4.9 min. Procedural success was 100%, and complete occlusion was observed after treatment and at the third-day follow-up. We observed ecchymosis in five patients (1.00%) at the entry site at the third-day follow-up. Phlebitis was encountered with six (1.20%) patients. No skin pigmentation, hematoma, paresthesia, deep vein thrombosis, or pulmonary embolism was observed. Kaplan-Meier analysis yielded an occlusion rate of 99.4% at the 12-month follow-up. All patients had significant improvement in venous clinical severity score and Aberdeen varicose vein questionnaire scores postoperatively ( p <0.0001). Venous clinical severity score scores decreased from 5.43 ± 0.87 to 0.6 ± 0.75. Aberdeen varicose vein questionnaire scores decreased from 18.32 ± 5.24 to 4.61 ± 1.42. Conclusions The procedure appears to be feasible, safe, and efficient in treating the great majority of incompetent great saphenous veins with this technique.

  5. IDENTIFICATION OF ANIMAL ADHESIVES USING DNA AMPLIFICATION

    DEFF Research Database (Denmark)

    Eriksen, Anne Marie; Kristensen, Hans Viborg; Bøllingtoft, Peder

    2014-01-01

    The aim of this study was to examine whether DNA was degraded in the manufacturing of animal glue. To test this, two different types of sturgeon glue (Acipenser sp.) were manufactured using historic recipes. One glue was boiled for a substantial amount of time and the other was kept under 75°C. DNA...... of the glue and in 18 out of 24 samples collected of the canvas. In four out of the five cases where it was not possible amplify DNA, the sample belongs to the smallest size of the canvas investigated. As shown in this study it is possible to get DNA out of boiled animal glue and glue applied onto canvas...

  6. From Nano to Micro: Importance of Structure and Architecture in Spider Silk Adhesives

    Science.gov (United States)

    Sahni, Vasav; Dhinojwala, Ali

    2012-02-01

    Spiders have developed outstanding adhesives over millions of years of evolution for prey capture and locomotion. We show that the structure and architecture of these adhesives play an important role in the adhesion. The adhesive produced by orb-weaving spiders to capture prey (viscid glue) is laid on a pair of silk fibers as micron-size glue drops composed of salts and glycoproteins. By stretching single drops, we show that viscid glue behaves like a viscoelastic solid and that elasticity is critical in enhancing adhesion caused by specific adhesive ligands by over 100 times. Comparing viscid glue with gumfoot glue, the glue produced by cob-weavers, the evolutionary descendants of orb-weavers, showed that, in spite of being produced in homologous aggregate glands, gumfoot glue behaves like a viscoelastic liquid. Moreover, gumfoot glue is humidity-resistant and viscid glue is humidity-sensitive. We use a synthetic strategy to spin beads-on-a-string (BOAS) architecture to mimic the adhesive properties of spider silk. Using these mimic threads, we show that the BOAS structure adheres more than a cylindrical structure during contact (collision of prey) and during separation (escape attempt of prey). These results inspire design of novel tunable adhesives.

  7. Vacation and polling models with retrials

    NARCIS (Netherlands)

    Boxma, O.J.; Resing, J.A.C.; Horváth, A.; Wolter, K.

    2014-01-01

    We study a vacation-type queueing model, and a single-server multi-queue polling model, with the special feature of retrials. Just before the server arrives at a station there is some deterministic glue period. Customers (both new arrivals and retrials) arriving at the station during this glue

  8. Analysis and optimization of vacation and polling models with retrials

    NARCIS (Netherlands)

    Abidini, M.A.; Boxma, O.J.; Resing, J.A.C.

    2016-01-01

    We study a vacation-type queueing model, and a single-server multi-queue polling model, with the special feature of retrials. Just before the server arrives at a station there is some deterministic glue period. Customers (both new arrivals and retrials) arriving at the station during this glue

  9. Analysis and optimization of vacation and polling models with retrials

    NARCIS (Netherlands)

    Abidini, M.A.; Boxma, O.J.; Resing, J.A.C.

    2015-01-01

    We study a vacation-type queueing model, and a single-server multi-queue polling model, with the special feature of retrials. Just before the server arrives at a station there is some deterministic glue period. Customers (both new arrivals and retrials) arriving at the station during this glue

  10. Multi-Ethnic Curriculum Guide

    Science.gov (United States)

    1972-02-18

    ceiling to floor in a scroll-like fashion. PAINTING - - SAND PAINTING Materiais: Colored aquarium sand or sand made from cornmeal and colored with food...Sprinkle different colors ol .Iluo r cornmeal mixture over the glue. 3. Let the glue dry. Gently shake off the loose cornmical. EARTH PAINTING Materials

  11. Controlled Release Formulation of Indomethacin Prepared With Bee ...

    African Journals Online (AJOL)

    Abstract. Purpose: To prepare and evaluate new sustained release formulations of indomethacin based on extracts of propolis (bee glue). Methods: Standardization of propolis (bee glue) extracts was performed by high performance liquid chromatography (HPLC) and determination of the values of fat and fixed oils. Several ...

  12. 75 FR 27991 - Notice of Petitions by Firms for Determination of Eligibility To Apply for Trade Adjustment...

    Science.gov (United States)

    2010-05-19

    ..., varnish, glue, inlay, sawing, planing, sanding equipment. Process: Plane and sand wood, cut wood pieces, do inlay, glue, sand, stain, varnish, add hardware, inspect, ship. Sioux Corporation One Sioux Plaza.... Quality Rolling & Deburring Inc....... 135 South Main Street, 5/5/2010 Quality Rolling & Deburring...

  13. Palaeoproteomic Profiling of Conservation Layers on a 14th Century Italian Wall Painting

    DEFF Research Database (Denmark)

    Mackie, Meaghan Emma; Rüther, Patrick Leopold; Samodova, Diana

    2018-01-01

    : sheep and cow glue and chicken and duck egg white. Analysis of post-translational modifications detected several photo-oxidation products, which suggest that the egg experienced prolonged exposure to UV light and was likely applied long before the glue layer. Additionally, glycation products detected...

  14. Vivostat®: an autologous fibrin sealant as useful adjunct in endoscopic transnasal CSF-leak repair.

    Science.gov (United States)

    Tomazic, Peter Valentin; Edlinger, Stefan; Gellner, Verena; Koele, Wolfgang; Gerstenberger, Claus; Braun, Hannes; Mokry, Michael; Stammberger, Heinz

    2015-06-01

    The benefit of fibrin glue for reduction of postoperative CSF-leaks after endoscopic skull base surgery is not clearly evident in literature. However, its use is supposed to be beneficial in fixing grafting material. As of today there is no specific data available for otolaryngological procedures. A retrospective data analysis at a tertiary care referral center on 73 patients treated endoscopically transnasally for CSF-leaks at the ENT-department Graz between 2009 and 2012 was performed. Primary closure rate between conventional fibrin glue and autologous fibrin glue were analyzed. The Vivostat(®) system was used in 33 CSF-leak closures and in 40 cases conventional fibrin glue was used. Comparing the two methods the primary closure rate using the autologous Vivostat(®) system was 75.8 and 85.0 % with conventional fibrin glue. The secondary closure the rates were 90.9 % with Vivostat(®) 92.5 % with conventional fibrin glue. The Vivosat(®) system is a useful adjunct in endoscopic CSF-leak closure. Its advantages over conventional fibrin glue are its application system for fixation of grafting material particularly in underlay techniques. Despite this advantage it cannot replace grafting material or is a substitute for proper endoscopic closure which is reflected by the closure rates.

  15. Occupational contact dermatitis caused by aniline epoxy resins in the aircraft industry.

    Science.gov (United States)

    Pesonen, Maria; Suuronen, Katri; Jolanki, Riitta; Aalto-Korte, Kristiina; Kuuliala, Outi; Henriks-Eckerman, Maj-Len; Valtanen, Ilona; Alanko, Kristiina

    2015-08-01

    Tetraglycidyl-4,4'-methylenedianiline (TGMDA) is an aniline epoxy resin used in, for example, resin systems of pre-impregnated composite materials (prepregs) of the aircraft industry. Allergic contact dermatitis caused by TGMDA in prepregs has been described previously. To report on 9 patients with occupational allergic contact dermatitis caused by TGMDA in epoxy glues used in helicopter assembly. The patients were examined with patch testing at the Finnish Institute of Occupational Health in 2004-2009. The first patient was diagnosed by testing both components of two epoxy glues from the workplace, and was also tested with glue ingredients, including TGMDA. The following patients were tested with the glues and TGMDA. The resin parts of the glues were analysed for their epoxy compounds, including TGMDA. All of the patients had a patch test reaction to one or both of the resin parts of the TGMDA-containing glues. Eight of them had a strong allergic reaction to TGMDA, and one had a doubtful reaction to TGMDA. Two of the patients also had an allergic reaction to triglycidyl-p-aminophenol (TGPAP), another aniline epoxy resin, which was not present in the TGMDA-containing glues. In aircraft industry workers with suspected occupational dermatitis, aniline epoxy resins should be considered and patch tested as possible contact allergens. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Robust cross-links in molluscan adhesive gels: testing for contributions from hydrophobic and electrostatic interactions.

    Science.gov (United States)

    Smith, A M; Robinson, T M; Salt, M D; Hamilton, K S; Silvia, B E; Blasiak, R

    2009-02-01

    The cross-linking interactions that provide cohesive strength to molluscan adhesive gels were investigated. Metal-based interactions have been shown to play an important role in the glue of the slug Arion subfuscus (Draparnaud), but other types of interactions may also contribute to the glue's strength and their role has not been investigated. This study shows that treatments that normally disrupt hydrophobic or electrostatic interactions have little to no effect on the slug glue. High salt concentrations and non-ionic detergent do not affect the solubility of the proteins in the glue or the ability of the glue proteins to stiffen gels. In contrast, metal chelation markedly disrupts the gel. Experiments with gel filtration chromatography identify a 40 kDa protein that is a central component of the cross-links in the glue. This 40 kDa protein forms robust macromolecular aggregations that are stable even in the presence of high concentrations of salt, non-ionic detergent, urea or metal chelators. Metal chelation during glue secretion, however, may block some of these cross-links. Such robust, non-specific interactions in an aqueous environment are highly unusual for hydrogels and reflect an intriguing cross-linking mechanism.

  17. Optimized adhesives for strong, lightweight, damage-resistant, nanocomposite materials: new insights from natural materials

    International Nuclear Information System (INIS)

    Hansma, P K; Turner, P J; Ruoff, R S

    2007-01-01

    From our investigations of natural composite materials such as abalone shell and bone we have learned the following. (1) Nature is frugal with resources: it uses just a few per cent glue, by weight, to glue together composite materials. (2) Nature does not avoid voids. (3) Nature makes optimized glues with sacrificial bonds and hidden length. We discuss how optimized adhesives combined with high specific stiffness/strength structures such as carbon nanotubes or graphene sheets could yield remarkably strong, lightweight, and damage-resistant materials

  18. Optimized adhesives for strong, lightweight, damage-resistant, nanocomposite materials: new insights from natural materials

    Energy Technology Data Exchange (ETDEWEB)

    Hansma, P K [Physics Department, Broida Hall, University of California, Santa Barbara, CA 93106 (United States); Turner, P J [Physics Department, Broida Hall, University of California, Santa Barbara, CA 93106 (United States); Ruoff, R S [Department of Mechanical Engineering, Northwestern University, 2145 Sheridan Road, Evanston, IL 60208-3111 (United States)

    2007-01-31

    From our investigations of natural composite materials such as abalone shell and bone we have learned the following. (1) Nature is frugal with resources: it uses just a few per cent glue, by weight, to glue together composite materials. (2) Nature does not avoid voids. (3) Nature makes optimized glues with sacrificial bonds and hidden length. We discuss how optimized adhesives combined with high specific stiffness/strength structures such as carbon nanotubes or graphene sheets could yield remarkably strong, lightweight, and damage-resistant materials.

  19. Glueballs, hermaphrodites and QCD problems for baryon spectroscopy

    International Nuclear Information System (INIS)

    Close, F.E.

    1981-08-01

    Spin-orbit splittings in baryon spectroscopy are examined with relevance to QCD: successes and failures are discussed. Claims to have seen glueballs are evaluated and the possibility of hermaphrodites-states containing quarks and glue - is mentioned. (author)

  20. Expression of collagen type I and II, aggrecan and SOX9 genes in mesenchymal stem cells on different bioscaffolds

    Directory of Open Access Journals (Sweden)

    Mahdieh Ghiasi

    2015-06-01

    Conclusion: The use of natural fibrin glue scaffold can be considered as a suitable environment for proliferation and differentiation of adipose-derived mesenchymal stem cells in cartilage tissue engineering.

  1. Experimental search for gluonic mesons

    International Nuclear Information System (INIS)

    Couchot, F.

    1987-09-01

    The present experimental situation is very rich and rather complex, so this paper is not a full review of the state of the art, but an approach of several methods that have been used to reach the world of glue

  2. The Modular Construction of DNA Double Helix

    Indian Academy of Sciences (India)

    discovery, DNA structure has been able to disseminate knowl- edge of key ... band a. This procedure would place segment a, overlapping with d. Glue securely a ... Because of alignment problems, unless great care is taken, the modules do ...

  3. Effect of methotrexate combined with ginger, silymarin or propolis on ...

    African Journals Online (AJOL)

    aghomotsegin

    2015-02-16

    Feb 16, 2015 ... the same MTX dose combined with ginger, silymarin or propolis oral administration. The doses of ... Propolis (bee glue) is a natural antioxidant produced .... labeled by VIC fluorescent dye and the three target gene cDNA.

  4. East African Journal of Sciences (2007) Volume 1 (1) 69-78 ...

    African Journals Online (AJOL)

    different beverages, medicines, and water-soluble glues. (EFAP, 1994 ... The altitudes of the study districts range from 250 –. 560 m in ..... sieberiana in boiling water also increased germination .... Subsistence Change among the Sandawe of.

  5. Hardware removal - extremity

    Science.gov (United States)

    ... such as pins, plates, or screws to help fix a broken bone or to correct an abnormality ... graft . Your surgeon will close the incision with stitches, staples, or special glue. It will be covered ...

  6. Otitis media with effusion

    Science.gov (United States)

    OME; Secretory otitis media; Serous otitis media; Silent otitis media; Silent ear infection; Glue ear ... from the tube and is swallowed. OME and ear infections are connected in two ways: After most ear ...

  7. AFRREV STECH

    African Journals Online (AJOL)

    User

    technology This paper will focus on using VHDL to design an application specific integrated circuit (ASIC) liquid dispenser controller system while targeting .... applications, from implementing random glue logic to prototyping small gate arrays.

  8. Proton mass decomposition

    Science.gov (United States)

    Yang, Yi-Bo; Chen, Ying; Draper, Terrence; Liang, Jian; Liu, Keh-Fei

    2018-03-01

    We report the results on the proton mass decomposition and also on the related quark and glue momentum fractions. The results are based on overlap valence fermions on four ensembles of Nf = 2 + 1 DWF configurations with three lattice spacings and volumes, and several pion masses including the physical pion mass. With 1-loop pertur-bative calculation and proper normalization of the glue operator, we find that the u, d, and s quark masses contribute 9(2)% to the proton mass. The quark energy and glue field energy contribute 31(5)% and 37(5)% respectively in the MS scheme at µ = 2 GeV. The trace anomaly gives the remaining 23(1)% contribution. The u, d, s and glue momentum fractions in the MS scheme are consistent with the global analysis at µ = 2 GeV.

  9. Journal of Development and Communication Studies Vol. 4. No. 2 ...

    African Journals Online (AJOL)

    Thomas Gill

    Communication is crucial to the success of any human development effort. In rural .... examine the relationship between respondents' demographic characteristics and readership ..... Glue, Oil and Web: The Role of Community Newspapers.

  10. ATLAS HEC Photographs - Pictures of the TRIUMF Production Site

    CERN Multimedia

    Wielers, M.

    2000-01-01

    Photo 1 - Arrival of Copper Plates Photo 2 - Cleaning of Copper Plates Photo 3 - Stacking Clean Room Photo 4 - Glue Press used for PAD Board Production Photo 5 - Cut honeycomb being removed from Steel Rule Die Photo 6 - Brake Press

  11. Glial Cells: The Other Cells of the Nervous System

    Indian Academy of Sciences (India)

    nervous system and that glial cells were a mere glue holding neurons in place, Schleich ... fact that these cells did not show any electrical activity like neurons or muscles ... membrane potential higher than that of the surrounding neu- rons.

  12. Bilateral cervical lung hernia with T1 nerve compression.

    Science.gov (United States)

    Rahman, Mesbah; Buchan, Keith G; Mandana, Kyapanda M; Butchart, Eric G

    2006-02-01

    Lung hernia is a rare condition. Approximately one third of cases occur in the cervical position. We report a case of bilateral cervical lung hernia associated with neuralgic pain that was repaired using bovine pericardium and biological glue.

  13. Higgs boson transverse momentum distribution

    CERN Multimedia

    CERN. Geneva

    2018-01-01

    I will review  the recent progress in understanding Higgs boson transverse momentum distribution focusing on effects that go beyond the point-like approximation for the Higgs-glue interaction vertex.

  14. Glued versus stapled anastomosis of the colon: An experimental study to determine comparative resistance to intraluminal pressure

    Directory of Open Access Journals (Sweden)

    Jiri Paral

    2014-07-01

    Conclusion: Healing with absorbable synthetic glue was as good as with staples. Glued anastomoses resisted pressures that were statistically significantly higher than physiological intraluminal colon pressures but lower than stapled ones.

  15. Inhalants

    Science.gov (United States)

    ... most commonly abuse glue, shoe polish, spray paints, gasoline, and lighter fluid. New users ages 16–17 ... paint thinners or removers, degreasers, dry- cleaning fluids, gasoline, and lighter fluid  Art or office supply solvents , ...

  16. Deliberate self-harming application of superglue in the nose: case report and literature review.

    Science.gov (United States)

    Tikka, T; Al Abduwani, J; Costello, D

    2015-01-01

    Accidental and non-accidental applications of superglue in the ear, nose and oral cavity have been reported previously. Surgical removal of glue from the nose is the current practice. This paper reports the case of an 18-year-old female, who presented with complete bilateral nasal occlusion due to deliberate self-application of superglue in both nostrils to avoid nasogastric tube insertion. Removal of glue was accomplished with a combination of local anaesthetic cream and acetone-soaked cotton buds, which caused only minimal discomfort to the patient. All traces of glue disappeared within 10 days, without causing damage to the nasal mucosa, nasal blockage or pain. To the best of our knowledge, this is the first case report of deliberate self-application of superglue in the nose. A successful non-surgical management option for the removal of glue from the nose is introduced.

  17. Critical role of the sample preparation in experiments using piezoelectric actuators inducing uniaxial or biaxial strains

    Czech Academy of Sciences Publication Activity Database

    Butkovičová, D.; Martí, Xavier; Saidl, V.; Schmoranzerová-Rozkotová, E.; Wadley, P.; Holý, V.; Němec, P.

    2013-01-01

    Roč. 84, č. 10 (2013), "103902-1"-"103902-5" ISSN 0034-6748 Institutional support: RVO:68378271 Keywords : glues * x-ray diffraction * lattice constant Subject RIV: BE - Theoretical Physics Impact factor: 1.584, year: 2013

  18. Controlled Release Formulation of Indomethacin Prepared With Bee ...

    African Journals Online (AJOL)

    Erah

    2010-12-27

    Dec 27, 2010 ... Results: The results show that, although the release rate of formulations F1 - F7 did not show any ... Keywords: Propolis (bee glue), Indomethacin, Controlled release, Zero order kinetics, Waxy materials ... focus of interest.

  19. SCALAR MULTI-PASS ATOMIC MAGNETOMETER

    Science.gov (United States)

    2017-08-01

    photolithographic method or a small droplet of UV (Ultra-Violet) curing glue that can be dissolved after the application of the HR coating. However...fabricated using d) photolithography or e) removal of a UV curing glue drop applied before HR coating. A physical hole with a 200µm diameter (f) drilled...outside magnetic shields on a non-magnetic optical table. The pump and probe beams enter through tubes visible on either side of the oven. Center panel

  20. Endoscopic ultrasound coil placement of gastric varices: Emerging modality for recurrent bleeding gastric varices

    Directory of Open Access Journals (Sweden)

    Yogesh Harwani

    2014-01-01

    Full Text Available Gastric varices are the probable source of bleeding in 10-36% of patients, with acute variceal bleeding and carry high mortality and rebleeding rates. Till date, cyanoacrylate glue injection is considered as the standard of care but has high complication rate. Endoscopic ultrasound (EUS guided coil placement is a new emerging technique of management of gastric varices. In this case report, we detail the EUS guided coil placement for management of gastric varices after failed glue injections.

  1. Semi-insulating GaAs detectors of fast neutrons

    International Nuclear Information System (INIS)

    Sagatova, A.; Sedlackova, K.; Necas, V.; Zatko, B.; Dubecky, F.; Bohacek, P.

    2012-01-01

    The present work deals with the technology of HDPE neutron conversion layer application on the surface of semi-insulating (SI) GaAs detectors via developed polypropylene (PP) based glue. The influence of glue deposition on the electric properties of the detectors was studied as well as the ability of the detectors to register the fast neutrons from "2"3"9Pu-Be neutron source. (authors)

  2. Studies of adhesives and metal contacts on silicon strip sensors for the ATLAS Inner Tracker

    OpenAIRE

    Poley, Anne-Luise

    2018-01-01

    This thesis presents studies investigating the use of adhesives on the active area of silicon strip sensors for the construction of silicon strip detector modules for the ATLAS Phase-II Upgrade. 60 ATLAS07 miniature sensors were tested using three UV cure glues in comparison with the current baseline glue (a non-conductive epoxy).The impact of irradiation on the chemical composition of all adhesives under investigation was studied using three standard methods for chemical analysis: quadrupole...

  3. Investigation into the Quality of Thermally Treated Package Lamination

    Directory of Open Access Journals (Sweden)

    Darius Kazlauskas

    2011-02-01

    Full Text Available The article deals with the problem of delaminating the package after pasteurization at relatively high temperatures. The main parameters of the lamination process influencing lamination strength were determined. The role of the amount of lamination glue and tension in the rewinder for two glue types were experimentally examined defining lamination regimes at which the process of delamination is excluded.Article in Lithuanian

  4. Science 101: Why Don't Spiders Stick to Their Own Webs?

    Science.gov (United States)

    Robertson, Bill

    2011-01-01

    This article explains why spiders don't stick to their webs. Spiders don't get stuck in their own webs (and they aren't immune to their own glue) because they use a combination of sticky and nonsticky threads (different glands for producing those), and the glue is in droplets that the spider can avoid but the prey can't. The spider's nervous…

  5. Production chain of CMS pixel modules

    CERN Multimedia

    2006-01-01

    The pictures show the production chain of pixel modules for the CMS detector. Fig.1: overview of the assembly procedure. Fig.2: bump bonding with ReadOut Chip (ROC) connected to the sensor. Fig.3: glueing a raw module onto the baseplate strips. Fig.4: glueing of the High Density Interconnect (HDI) onto a raw module. Fig.5: pull test after heat reflow. Fig.6: wafer sensor processing, Indium evaporation.

  6. Emission of organic substances from chip-boards

    Energy Technology Data Exchange (ETDEWEB)

    Deppe, H.J.

    1982-01-01

    A relatively small number of investigations on emissions of organic substances from chip-board is available up to now. The emissions known to date are caused by glues or other additives rather than by the wood itself. As concerns aminoplast glues (urea-formaldehyde or melamine-formaldehyde resins) the most important point of public interest has been the off-gassing of formaldehyde from chip-board. Chip-board with phenol-formaldehyde glues has been known in some cases to give off phenol. The formation of diamino diphenyl methane from isocyanate glues is still a matter of discussion. A further source for possible emissions are wood and fire protectives which are added during the manufacturing process. Finally, coating of chip-board may lead to emissions of organic substances. The lack of adequate detection methods has so far delayed the treatment of questions in relation to emissions from chip-board. Even now, there are numerous problems in this field especially when investigating isocyanate glues. Problems in relation to the origin of emissions due to the kind of glue used and the manufacturing process are discussed, and proposals are made how to solve some of these problems. The question of the health risk is dealt with from the view-point of the civil engineer and in an general economic context.

  7. Osteoprogenitor cell therapy in an equine fracture model.

    Science.gov (United States)

    McDuffee, Laurie A; Pack, LeeAnn; Lores, Marcos; Wright, Glenda M; Esparza-Gonzalez, Blanca; Masaoud, Elmabrok

    2012-10-01

    To compare the efficacy of osteoprogenitors in fibrin glue to fibrin glue alone in bone healing of surgically induced ostectomies of the fourth metacarpal bones in an equine model. Experimental. Adult horses (n = 10). Segmental ostectomies of the 4th metacarpal bone (MC4) were performed bilaterally in 10 horses. There was 1 treatment and 1 control limb in each horse. Bone defects were randomly injected with either fibrin glue and osteoprogenitor cells or fibrin glue alone. Radiography was performed every week until the study endpoint at 12 weeks. After euthanasia, bone healing was evaluated using radiography and histology. Analysis of radiographic data was conducted using a linear-mixed model. Analysis of histologic data was conducted using a general linear model. Statistical significance was set at P bone healing revealed no significant difference between treatment and control limbs. Radiographic scoring results also showed that the treatment effect was not significant. Histologic analysis was consistent with radiographic analysis showing no significant difference between the area of bone present in treatment and control limbs. Injection of periosteal-derived osteoprogenitors in a fibrin glue carrier into surgically created ostectomies of MC4 does not accelerate bone healing when compared with fibrin glue alone. © Copyright 2012 by The American College of Veterinary Surgeons.

  8. Gluing for Raman lidar systems using the lamp mapping technique.

    Science.gov (United States)

    Walker, Monique; Venable, Demetrius; Whiteman, David N

    2014-12-20

    In the context of combined analog and photon counting (PC) data acquisition in a Lidar system, glue coefficients are defined as constants used for converting an analog signal into a virtual PC signal. The coefficients are typically calculated using Lidar profile data taken under clear, nighttime conditions since, in the presence of clouds or high solar background, it is difficult to obtain accurate glue coefficients from Lidar backscattered data. Here we introduce a new method in which we use the lamp mapping technique (LMT) to determine glue coefficients in a manner that does not require atmospheric profiles to be acquired and permits accurate glue coefficients to be calculated when adequate Lidar profile data are not available. The LMT involves scanning a halogen lamp over the aperture of a Lidar receiver telescope such that the optical efficiency of the entire detection system is characterized. The studies shown here involve two Raman lidar systems; the first from Howard University and the second from NASA/Goddard Space Flight Center. The glue coefficients determined using the LMT and the Lidar backscattered method agreed within 1.2% for the water vapor channel and within 2.5% for the nitrogen channel for both Lidar systems. We believe this to be the first instance of the use of laboratory techniques for determining the glue coefficients for Lidar data analysis.

  9. Nutrient Deprivation Induces Property Variations in Spider Gluey Silk

    Science.gov (United States)

    Blamires, Sean J.; Sahni, Vasav; Dhinojwala, Ali; Blackledge, Todd A.; Tso, I-Min

    2014-01-01

    Understanding the mechanisms facilitating property variability in biological adhesives may promote biomimetic innovations. Spider gluey silks such as the spiral threads in orb webs and the gumfoot threads in cobwebs, both of which comprise of an axial thread coated by glue, are biological adhesives that have variable physical and chemical properties. Studies show that the physical and chemical properties of orb web gluey threads change when spiders are deprived of food. It is, however, unknown whether gumfoot threads undergo similar property variations when under nutritional stress. Here we tested whether protein deprivation induces similar variations in spiral and gumfoot thread morphology and stickiness. We manipulated protein intake for the orb web spider Nephila clavipes and the cobweb spider Latrodectus hesperus and measured the diameter, glue droplet volume, number of droplets per mm, axial thread width, thread stickiness and adhesive energy of their gluey silks. We found that the gluey silks of both species were stickier when the spiders were deprived of protein than when the spiders were fed protein. In N. clavipes a concomitant increase in glue droplet volume was found. Load-extension curves showed that protein deprivation induced glue property variations independent of the axial thread extensions in both species. We predicted that changes in salt composition of the glues were primarily responsible for the changes in stickiness of the silks, although changes in axial thread properties might also contribute. We, additionally, showed that N. clavipes' glue changes color under protein deprivation, probably as a consequence of changes to its biochemical composition. PMID:24523902

  10. Effectiveness of a new gelatin sealant system for dural closure.

    Science.gov (United States)

    Kawai, Hisashi; Nakagawa, Ichiro; Nishimura, Fumihiko; Motoyama, Yasushi; Park, Young-Su; Nakamura, Mitsutoshi; Nakase, Hiroyuki; Suzuki, Shuko; Ikada, Yoshito

    2014-10-01

    Watertight dural closure is imperative after neurosurgical procedures because inadequately treated leakage of cerebrospinal fluid (CSF) can have serious consequences. In this study, the authors test the use of a new gelatin glue as a dural sealant in in vitro and in vivo canine models of transdural CSF leakage. The in vitro model was sutured semicircles of canine dura mater and artificial dural substitute. The sutures were sealed with gelatin glue (n  =  20), fibrin glue (n  =  20), or a polyethylene glycol (PEG)-based hydrogel sealant (n  =  20). Each sample was set in a device to measure water pressure, and pressure was increased until leakage occurred. Bonding strength was subjectively evaluated. The in vivo model was dogs who underwent dural excision and received either no sealant (control group; n  =  5) or gelatin glue sealant (n  =  5) before dural closure. Twenty-eight days post-surgery, the maximum intracranial pressure was measured at the cisterna magna using Valsalva maneuver and tissue adhesion was evaluated. The water pressure at which leakage occurred in the in vitro model was higher with gelatin glue (76·5 ± 39·8 mmHg) than with fibrin glue (38·3 ± 27·4 mmHg, P control group (13·8 ± 4·0 mmHg, P control group (P  =  0·005). The new gelatin glue provides an effective watertight closure when used as an adjunct to sutured dural repair.

  11. Evaluation of novel biodegradable three-armed- and hyper-branched tissue adhesives in a meniscus explant model.

    Science.gov (United States)

    Bochyńska, A I; Hannink, G; Verhoeven, R; Grijpma, D W; Buma, P

    2017-05-01

    Current treatment methods to repair meniscal tears do not bring fully satisfactory results. Tissue adhesives are considered promising alternatives, since they are easy to apply and cause minimal tissue trauma. The first aim of this study was to analyze the adhesive properties of and tissue response to two recently developed biodegradable block copolymeric three-armed- and hyper-branched tissue adhesives. The second aim was to investigate if tissue surface modification with collagenase improves the attachment of the adhesives and increases the healing potential of the tissue. Cylindrical explants were harvested from bovine menisci. The central core of the explants was removed and glued back into the defect, with or without incubation in collagenase solution prior to gluing, using one of the novel glues, Dermabond® or fibrin glue. The repair constructs were cultured in vitro for 1 and 28 days. Adhesion tests and histology were performed to analyze the effects of the glue in combination with the additional treatment. The adhesive strength of the novel glues was 40-50 kPa, which was significantly higher than that of fibrin glue (15 kPa). Cells were present in direct contact with the glues, and the tissue remained vital during the whole culture period. Increased cellularity around the tear in the collagenase treated explants was observed after 1 day. The two newly developed tissue adhesives are attractive materials to be used for repair of meniscal tears. The beneficial influence of collagenase treatment in treating meniscal tears with glues still needs to be confirmed in more clinical relevant studies. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 1405-1411, 2017. © 2017 Wiley Periodicals, Inc.

  12. IMPACTS OF DIFFERENT JOINT ANGLES AND ADHESIVES ON DIAGONAL TENSION PERFORMANCES OF BOX-TYPE FURNITURE

    Directory of Open Access Journals (Sweden)

    Musa Atar

    2010-02-01

    Full Text Available The goal of this study was to determine the effects of different joint angles and adhesives on diagonal tension performances of the box-type furniture made from solid wood and medium density fiberboard (MDF. After drilling joints of 75º, 78º, 81º, 84º, and 87º degrees on Oriental beech, European oak, Scotch pine, and MDF samples, a diagonal tensile test was applied on corners glued with polyvinyl acetate (PVAc and polyurethane (D-VTKA = Desmodur-Vinyl Trieketonol Acetate according to ASTM D 1037 standard. With reference to the obtained results, the highest tensile strength was obtained in European oak with PVAc glue and joint angle of 84º, while the lowest value was obtained in MDF with D-VTKA glue and joint angle of 75º. Considering the interaction of wood, adhesive, and joint angle, the highest tensile strength was obtained in European oak with joint angle of 81º and D-VTKA glue (1.089 N.mm-2, whereas the lowest tensile strength was determined in MDF with joint angle of 75º and PVAc glue (0.163 N.mm-2. Therefore, PVAc as glue and 81º as joint angle could be suggested to obtain some advantageous on the dovetail joint process for box-type furniture made from both solid wood and MDF.

  13. Compression properties and dissolution of bioactive glass S53P4 and n-butyl-2 cyanoacrylate tissue adhesive-composite.

    Science.gov (United States)

    Sarin, Jussi; Hiltunen, Markus; Hupa, Leena; Pulkkinen, Jaakko; Vallittu, Pekka K

    2016-09-28

    Bioactive glass (BG)-containing fiber-reinforced composite implants, typically screw-retained, have started to be used clinically. In this study, we tested the mechanical strength of composites formed by a potential implant adhesive of n-butyl-2-cyanoacrylate glue and BG S53P4 particles. Water immersion for 3, 10 or 30 days had no adverse effect on the compression strength. When cyanoacrylate glue-BG-composites were subjected to simulated body fluid immersion, the average pH rose to 7.52 (SD 0.066) from the original value of 7.35 after 7 days, and this pH increment was smaller compared to BG particle-group or fibrin glue-BG-composite group. Based on these results n-butyl-2 cyanoacrylate glue, by potentially producing a strong adhesion, might be considered a possible alternative for fixation of BG S53P4 containing composite implants. However, the mechanical and solubility properties of the cyanoacrylate glue may not encourage the use of this tissue adhesive with BG particles.

  14. Linerless label device and method

    KAUST Repository

    Binladen, Abdulkari

    2016-01-14

    This apparatus and method for applying a linerless label to an end user product includes a device with a printer for printing on a face surface of a linerless label, and a release coat applicator for applying a release coat to the face surface of the label; another device including an unwinder unit (103) to unwind a roll of printed linerless label; a belt (108); a glue applicator (102) for applying glue to the belt; a nip roller (106) for contacting and applying pressure to the face surface of the linerless label such that the glue on the belt transfers to the back surface of the linerless label; at least one slitting knife 105) positioned downstream the belt and a rewinder unit (104) positioned downstream the slitting knife; and a third device which die cuts and applies the linerless label to an end user object.

  15. Lignonsulfonate-phenolformaldehyrde adhesive: a potential binder for wood panel industries

    International Nuclear Information System (INIS)

    Akhtar, T.; Lutfullah, G.; Ullah, Z.

    2011-01-01

    Spent sulfite liquor (SSL) was obtained from a paper mill based on grassy pulp material (bagasse, kaigrass and wheat straws). Lignosulfonate (LS) was isolated from SSL by polymerization reaction, initiated with concentrated hydrochloric acid. Different adhesives were prepared by gradual replacement of phenol by LS in phenol-formaldehyde (PF) resole resin. The strength of these resins was evaluated by glue block shear test in two wood species, in both dry and wet states. Maximum shear strength and wood failure was obtained by 20% addition of lignosulfonate to PF resin. No significant difference was observed in shear strength and wood failure of the two wood species in dry and wet states indicating that the resin obtained is waterproof. The results obtained from this study were compared with different commercial glues. Our results were found better than these glues event at a ratio 50: 50 of PF to lignosulfonate. (author)

  16. Juvenile nasopharyngeal angiofibroma with skull base invasion : intratumoral direct puncture embolization

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Hye Young; Kim, Sun Yong; Suh, Jung Ho; Park, Kee Hyun [Ajou Univ., Suwon (Korea, Republic of). Coll. of Medicine

    1998-04-01

    The purpose of this study is to demonstrate the utility and efficacy of percutaneous direct glue embolization for juvenile nasopharyngeal angiofibromas with skull base invasion. In nine cases of juvenile nasopharyngeal angiofibromas with invasion of the skull base, embolization under general anethesia was performed. Using an 18G spinal needle, direct puncture were made via the transnasal or mandibular sciatic notch. A glue-lipiodol mixture (1:1 -1:3) was injected slowly for 15 to 30 seconds under fluoroscopic control; the number of post-embolization angiography and the distribution of embolic materials was assessed on CT within 1-3 days. The mass was surgically removed 3 to 7 days after embolization. Direct glue embolization of juvenile angiofibroma with skull base invasion appears to be a simple and safe procedure. The technique could be used for other hypervascular lesions in the base of the skull or parapharyngeal space. (author). 19 refs., 1 tab., 2 figs.

  17. Juvenile nasopharyngeal angiofibroma with skull base invasion : intratumoral direct puncture embolization

    International Nuclear Information System (INIS)

    Shin, Hye Young; Kim, Sun Yong; Suh, Jung Ho; Park, Kee Hyun

    1998-01-01

    The purpose of this study is to demonstrate the utility and efficacy of percutaneous direct glue embolization for juvenile nasopharyngeal angiofibromas with skull base invasion. In nine cases of juvenile nasopharyngeal angiofibromas with invasion of the skull base, embolization under general anethesia was performed. Using an 18G spinal needle, direct puncture were made via the transnasal or mandibular sciatic notch. A glue-lipiodol mixture (1:1 -1:3) was injected slowly for 15 to 30 seconds under fluoroscopic control; the number of post-embolization angiography and the distribution of embolic materials was assessed on CT within 1-3 days. The mass was surgically removed 3 to 7 days after embolization. Direct glue embolization of juvenile angiofibroma with skull base invasion appears to be a simple and safe procedure. The technique could be used for other hypervascular lesions in the base of the skull or parapharyngeal space. (author). 19 refs., 1 tab., 2 figs

  18. Studies of adhesives and metal contacts on silicon strip sensors for the ATLAS Inner Tracker

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00407830; Moenig, Klaus

    2018-04-04

    This thesis presents studies investigating the use of adhesives on the active area of silicon strip sensors for the construction of silicon strip detector modules for the ATLAS Phase-II Upgrade. 60 ATLAS07 miniature sensors were tested using three UV cure glues in comparison with the current baseline glue (a non-conductive epoxy). The impact of irradiation on the chemical composition of all adhesives under investigation was studied using three standard methods for chemical analysis: quadrupole time-of-flight mass spectroscopy, gel permeability chromatography and gas chromatography combined with mass spectrometry (GC-MS). GC-MS analyses of glue sample extracts before and after irradiation showed molecule cross-linking and broken chemical bonds to different extents and allowed to quantify the radiation hardness of the adhesives under investigation. Probe station measurements were used to investigate electrical characteristics of sensors partially covered with adhesives in comparison with sensors without adhesiv...

  19. Fabrication of a microfluidic chip by UV bonding at room temperature for integration of temperature-sensitive layers

    Science.gov (United States)

    Schlautmann, S.; Besselink, G. A. J.; Radhakrishna Prabhu, G.; Schasfoort, R. B. M.

    2003-07-01

    A method for the bonding of a microfluidic device at room temperature is presented. The wafer with the fluidic structures was bonded to a sensor wafer with gold pads by means of adhesive bonding, utilizing an UV-curable glue layer. To avoid filling the fluidic channels with the glue, a stamping process was developed which allows the selective application of a thin glue layer. In this way a microfluidic glass chip was fabricated that could be used for performing surface plasmon resonance measurements without signs of leakage. The advantage of this method is the possibility of integration of organic layers as well as other temperature-sensitive layers into a microfluidic glass device.

  20. A non-linear and stochastic response surface method for Bayesian estimation of uncertainty in soil moisture simulation from a land surface model

    Directory of Open Access Journals (Sweden)

    F. Hossain

    2004-01-01

    Full Text Available This study presents a simple and efficient scheme for Bayesian estimation of uncertainty in soil moisture simulation by a Land Surface Model (LSM. The scheme is assessed within a Monte Carlo (MC simulation framework based on the Generalized Likelihood Uncertainty Estimation (GLUE methodology. A primary limitation of using the GLUE method is the prohibitive computational burden imposed by uniform random sampling of the model's parameter distributions. Sampling is improved in the proposed scheme by stochastic modeling of the parameters' response surface that recognizes the non-linear deterministic behavior between soil moisture and land surface parameters. Uncertainty in soil moisture simulation (model output is approximated through a Hermite polynomial chaos expansion of normal random variables that represent the model's parameter (model input uncertainty. The unknown coefficients of the polynomial are calculated using limited number of model simulation runs. The calibrated polynomial is then used as a fast-running proxy to the slower-running LSM to predict the degree of representativeness of a randomly sampled model parameter set. An evaluation of the scheme's efficiency in sampling is made through comparison with the fully random MC sampling (the norm for GLUE and the nearest-neighborhood sampling technique. The scheme was able to reduce computational burden of random MC sampling for GLUE in the ranges of 10%-70%. The scheme was also found to be about 10% more efficient than the nearest-neighborhood sampling method in predicting a sampled parameter set's degree of representativeness. The GLUE based on the proposed sampling scheme did not alter the essential features of the uncertainty structure in soil moisture simulation. The scheme can potentially make GLUE uncertainty estimation for any LSM more efficient as it does not impose any additional structural or distributional assumptions.

  1. The effect of fibrin sealant on bioactive glass S53P4 particles – pH impact and dissolution characteristics in vitro

    Directory of Open Access Journals (Sweden)

    Jussi Sarin

    2016-12-01

    Full Text Available Fibrin glue, a two-component tissue adhesive, has a range of clinical indications. Bioactive glass (BG S53P4 has been approved for clinical use in several craniomaxillofacial and orthopedic applications. Although sometimes used simultaneously, there is no data available regarding the possible interaction of these two biocompatible substances. In this in vitro study, using a BG particle concentration of 4 mg/ml, a 0.4 unit pH increment (p < 0.001 was observed in simulated body fluid (SBF after a 7-day incubation period. The addition of fibrin glue (0.13 g, SD 0.04; or 3.7 mg/ml on top of the BG particles raised further the pH by 0.5 units (p < 0.001. The difference between these groups was statistically significant (p = 0.008. With a BG concentration of 25 mg/ml and a fibrin glue concentration of 18 mg/ml during a 14-day incubation period, a pH increment of 0.6 units and SBF ion concentration change of Ca, K, Mg, Na, P and Si ions was seen. Moreover, a penetration depth between 4 and 6 mm was observed when fibrin glue was applied on top of a bed of BG particles. Conclusions: Fibrin glue is not likely to have a distracting effect on BG-induced pH increase of the SBF although it might delay early BG surface reactions based on ion concentration measurements. Fibrin glue penetrated to the interparticle space to some extent, binding the particles together for easy clinical use of BG.

  2. PEMANFAATAN DAUN JATI SEBAGAI PIGMEN WARNA CAT TEMBOK

    OpenAIRE

    Effendy, Suhardi; Sulhadi, Sulhadi; Darsono, Teguh

    2017-01-01

    The utilization of teak leaf extract containing carotenoids for natural dyes on the manufacture of wall paint. Teak leaf extract boiled with 350 ml of water until boiling and filtered with screen mash T100. As glue is used a blend of tapioca flour and lime tohor as much as 75 grams with composition ratio (1: 3, 1: 1,3: 1). As a solvent used mix aqudes, PVAc glue and white cement. In this research, the process of making paint is by mixing all the material from pigment, adhesive, and solvent un...

  3. Investigation the Potential Replacement of the Old Corrugated Container (OCC) and Poplar Wood Flour Instead of Wheat Flour such as Urea-formaldehyde Adhesive Filler in the Plywood Industry

    OpenAIRE

    Kazem D.Hosseini; Meysam Mahdinia; Elham Farhid; Abdollah Elyasi

    2012-01-01

    Considering the value and importance of wheat flour in our country, replacement of a new type of filler instead of wheat flour in glue combination in plywood industry is necessary. In this study the possibility of using wood flour of poplar and OCC (old corrugated container) fiber as filler in the combination of urea formaldehyde glue has been studied. The plywood was manufactured from Poplar species (in core of plywood) and Hornbeam veneer (in back and face of plywood) on the basis of the st...

  4. Embracing equifinality with efficiency: Limits of Acceptability sampling using the DREAM(LOA) algorithm

    Science.gov (United States)

    Vrugt, Jasper A.; Beven, Keith J.

    2018-04-01

    This essay illustrates some recent developments to the DiffeRential Evolution Adaptive Metropolis (DREAM) MATLAB toolbox of Vrugt (2016) to delineate and sample the behavioural solution space of set-theoretic likelihood functions used within the GLUE (Limits of Acceptability) framework (Beven and Binley, 1992, 2014; Beven and Freer, 2001; Beven, 2006). This work builds on the DREAM(ABC) algorithm of Sadegh and Vrugt (2014) and enhances significantly the accuracy and CPU-efficiency of Bayesian inference with GLUE. In particular it is shown how lack of adequate sampling in the model space might lead to unjustified model rejection.

  5. [Conservative anal fistula treatment with collagenic plug and human fibrin sealant. Preliminary results].

    Science.gov (United States)

    Gubitosi, A; Moccia, G; Malinconico, F A; Docimo, G; Ruggiero, R; Iside, G; Avenia, N; Docimo, L; Foroni, F; Gilio, F; Sparavigna, L; Agresti, M

    2009-01-01

    The authors, on the basis of a long clinical experience with human fibrin glue in general surgery, compared two different extracellular matrix (collagen), Surgisis and TissueDura, with human fibrin glue, applied during the operation, and sometimes in postoperative, to obtain the healing of perianal fistulas. The collagenic extracellular matrix provides, according to the rationale suggested, an optimal three-dimensional structure for the fibroblastic implant and neoangiogenesis, hence for the fistula "fibrotizzation" and closure. The encouraging results for transphincteric fistulas and a simple and easy technique push to researchers on samples statistically significant.

  6. Hematological Parameters in the Volatile Substance Sniffers

    OpenAIRE

    Dündaröz, Ruşen; Ceylan, Süleyman; Denli, Metin; Açıkel, Cengizhan; Balım, Elvan; Özışık, Tahir

    2009-01-01

    SüleymanDemirel Üniversitesi TIP FAKÜLTESİ DERGİSİ: 1999 Eylül; 6(3) Hematological Parameters in the Volatile Substance Sniffers Ruşen Dündaröz, Süleyman Ceylan, Metin Denli, Cengiz Han Açıkel, Elvan Balım, Tahir Özışık Abstract Glue sniffing is a frequent problem among teenagers. Various chemical substances, especially toluene and benzene, contained in the glues kave been reported to be hematotoxic. The hematological parameters of 44 healthy teenagers ~...

  7. One-stage and two-stage penile buccal mucosa urethroplasty

    Directory of Open Access Journals (Sweden)

    G. Barbagli

    2016-03-01

    Full Text Available The paper provides the reader with the detailed description of current techniques of one-stage and two-stage penile buccal mucosa urethroplasty. The paper provides the reader with the preoperative patient evaluation paying attention to the use of diagnostic tools. The one-stage penile urethroplasty using buccal mucosa graft with the application of glue is preliminary showed and discussed. Two-stage penile urethroplasty is then reported. A detailed description of first-stage urethroplasty according Johanson technique is reported. A second-stage urethroplasty using buccal mucosa graft and glue is presented. Finally postoperative course and follow-up are addressed.

  8. View of the moving head of the gantry machine and the working area containingthe supply and assembly platforms (trays in green).

    CERN Multimedia

    Alan Honma

    1999-01-01

    The robotic assembly machine consists of the gantry positioning systemoutfitted with pickup tooling heads and camera+microscope for accurateposition measurements. The procedure is to place the components onthe working platforms and the machine applies glue, picks and placesthe silicon sensors and front-end hybrids onto the frames. The components are held in place by vacuum to prevent movement untilthe glue has cured. Up to four modules can be assembled at one time.The platforms are removable allowing assembly to continue on a newset of modules.

  9. Comparison of Different Encapsulating Adhesives to Enhance the Efficiencies and Lifetimes of Polymeric Solar Cells

    Science.gov (United States)

    Chung, Ming-Hua; Chen, Chen-Ming; Hsieh, Tsung-Eong; Tang, Rong-Ming; Tsai, Yu Sheng; Chu, Wei-Ping; Liu, Mark O.; Juang, Fuh-Shyang

    2009-04-01

    Polymeric solar cells (PSCs) with a derivative of C60 [[6,6]-phenyl C61-butyric acid methyl ester (PCBM)], and 3-hexylthiophene (P3HT) as active layers have been fabricated. The PSC devices were also packaged with glass and novel UV glues to improve their lifetimes and power conversion efficiencies (PCEs). After encapsulation with UV glue I, II, and III, the PCEs of PSCs reached 4, 4.82, and 6%, respectively, and their half-lifetimes increased to 16-18, 26-28, and 90 h, respectively, while the PCEs and half-lifetimes of PSCs without encapsulation were 3.76% and 2.5 h, respectively.

  10. Development of Softcore Processor based RTU for FBR

    International Nuclear Information System (INIS)

    Gour, Aditya; Santhana Raj, A.; Behera, R.P.; Murali, N.; Swaminathan, P.

    2010-01-01

    Remote Terminal Units (RTU) are used to acquire analog/digital signals and generate potential free contact outputs and send the acquired data through LAN. The aim of this design is to develop a Soft-Core Processor based RTU by implementing the glue logic along with 8051 microcontroller present in existing RTUs into a single FPGA, so that component count and power consumption on the board will be reduced and thereby achieving a higher reliability than before. Implementation of glue logic was done using VHDL and Altium's TSK51 Softcore was used in place of 8051 microcontroller. (author)

  11. Towards Uniform Access to Web Data and Services

    NARCIS (Netherlands)

    Harth, Andreas; Norton, Barry; Polleres, Axel; Sapkota, Brahmananda; Speiser, Sebastian; Stadtmüller, Steffen; Suominen, Osma

    2011-01-01

    A sizable amount of data on the Web is currently available via Web APIs that expose data in formats such as JSON or XML. Combining data from different APIs and data sources requires glue code which is typically not shared and hence not reused. We derive requirements for a mechanism that brings data

  12. Gastrointestinal helminths and external parasites of domestic rats ...

    African Journals Online (AJOL)

    A survey of domestic rats was conducted to investigate the prevalence of gastrointestinal helminths and external parasites in Maiduguri municipal between February and June 2015. Rats were randomly collected from residential sites within Maiduguri metropolis by trapping using mechanical and glue board traps. Trapped ...

  13. Detection of mechanical instability in DI-fluxgate sensors

    DEFF Research Database (Denmark)

    Pedersen, Lars W.; Matzka, Jürgen

    2012-01-01

    ’ during the DI-measurement. We have found a way to glue the ferromagnetic cores within the new sensors to make them mechanically stable. All sensors are tested very carefully before being used. Since the observed erroneous sensor offset due to loose sensor usually is extremely high, we can use a fast...

  14. Of what cloth are the ties that bind? National identity and support for the welfare state across 29 European countries

    NARCIS (Netherlands)

    Wright, M.; Reeskens, T.

    2013-01-01

    An oft-made claim is that national identity (NI) can function as social glue underpinning public support for the welfare state by encouraging the identification with co-nationals essential for redistribution. Empirical tests have largely ignored the possibility that the relationship depends on the

  15. Fracture strength of biomimetic composites: scaling views on nacre

    Energy Technology Data Exchange (ETDEWEB)

    Okumura, Ko [Department of Physics, Graduate School of Humanities and Sciences, Ochanomizu University, 2-1-1, Otsuka, Bunkyo-ku, Tokyo 112-8610 (Japan)

    2005-08-10

    Nacre, layered structure on the nanoscale, found inside certain seashells, shows remarkable strength due to the tiny amount of soft glues between hard sheets. In this paper, we develop an anisotropic elastic theory and fracture mechanics for the laminar structure at the level of scaling laws to reproduce the essence of the previous results in a much simpler way.

  16. Ants, rodents and seed predation in Proteaceae

    African Journals Online (AJOL)

    ... their nests extremely rapidly. One benefit of the ant-plant interaction may be seed escape ... (odourless to humans when dry) household glue or, b) placing seed in a Petri dish ... the layout of exclosures was completed. Response was not as.

  17. ISR Superconducting Quadrupoles

    CERN Multimedia

    1977-01-01

    Michel Bouvier is preparing for curing the 6-pole superconducting windings inbedded in the cylindrical wall separating liquid helium from vacuum in the quadrupole aperture. The heat for curing the epoxy glue was provided by a ramp of infrared lamps which can be seen above the slowly rotating cylinder. See also 7703512X, 7702690X.

  18. Evidence for explicit glueballs from the reaction π-p → phi phi n+

    International Nuclear Information System (INIS)

    Lindenbaum, S.J.

    1982-01-01

    Given QCD as an Ansatz and OZI (with appropriate restrictions) as a second Ansatz, I conclude we have discovered either two glueballs or two states very rich in resonating glue formed from one primary glueball mixing with a nearby quark state of the same quantum numbers, thus forming two states

  19. 29 CFR 784.108 - Operations not included in named operations on forms of aquatic “life.”

    Science.gov (United States)

    2010-07-01

    ... subject matter of the exemptions is concerned with “aquatic forms of animal and vegetable life,” the..., novelties, liquid glue, isinglass, pearl essence, and fortified or refined fish oil is not within these... 29 Labor 3 2010-07-01 2010-07-01 false Operations not included in named operations on forms of...

  20. Abeeb olufemi Salaam Community Reintegration Oyo, Oyo State ...

    African Journals Online (AJOL)

    list of illegal drugs (e.g., cannabis, heroin, co- caine, amphetamines): (a) they had ever used in their life; (b) they had used during the past twelve months. Further to the list of illegal drugs, the participants were asked to indicate whether they had used any alcoholic beverag- es (e.g., dry gin, kokino), solvents (e.g., glue, petrol ...

  1. Cavernous nerve stimulation and recording of intracavernous pressure in a rat

    DEFF Research Database (Denmark)

    Hox, Morten; Mann-Gow, Travis; Lund, Lars

    2018-01-01

    of the CN, without the need for lifting and drying, was achieved by using a 125 µm bipolar silver electrode and biocompatible silicon glue to isolate the electrode-nerve complex. This method prevents neuropraxia by reducing stretching and drying the nerve and provides complete isolation of the nerve...

  2. Computer Crafts for Kids.

    Science.gov (United States)

    Kuntz, Margy; Kuntz, Ann

    This work presents a collection of craft projects that can be created by children. Necessary for completion of each craft is an IBM-compatible computer running Windows, "Word for Windows 6.0," with a mouse, a printer, and plain white printer paper. Simple craft supplies, including glue and scissors, also are needed. In each activity the child is…

  3. Alternative mounting media for preservation of some protozoa.

    Science.gov (United States)

    Criado-Fornelio, A; Heredero-Bermejo, I; Pérez-Serrano, J

    2014-10-01

    Protozoa resistant stages are disintegrated when mounted in toluene-based media. To overcome such problem, three toluene-free mountants were tested on preserve Acanthamoeba spp and gregarines. Two commercial glues based on cyanoacrylate or trimethoxysilane were suitable for preserving both cysts and trophozoites. Hoyer's medium showed good results for mounting gregarine oocysts. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. SR-XRD and SR-FTIR study of the alteration of silver foils in medieval paintings.

    Science.gov (United States)

    Salvadó, Nati; Butí, Salvador; Labrador, Ana; Cinque, Gianfelice; Emerich, Hermann; Pradell, Trinitat

    2011-03-01

    Altarpieces and polychrome carved wood from the fifteenth century AD usually exhibit golden and silvery areas by the application of a very thin foil of metal. The metal foils were normally protected from the atmosphere by a varnish or resin which maybe either preserved or absent. Moreover, they were glued to the background surface by adhesive substances (egg yolk, drying oil or animal glue). The high proportion of the glueing substances often renders the development of reaction compounds. With time, silver alters blacken or simply disappear completely. In this paper, we study the alterations to metal foils from a selection of fifteenth century artworks showing different glueing agents, organic coatings and several degrees of conservation of the organic coatings and metal leafs. The submillimetric layered structure and the high variability and low amount of most of the compounds present in the different layers, as well as their differing nature (organic and inorganic) make the use of micron-sensitive high-resolution techniques essential for their study. In particular, the high resolution, high brilliance and small footprint renders synchrotron radiation most adequate for their study. SR-XRD was performed to identify the reaction compounds formed in the different layers; μFTIR was used at to identify the silver protecting organic coatings, the metal foil glueing layers and the corresponding reaction compounds. The results obtained suggest that atmospheric corrosion is the dominant mechanism, and therefore that the degree of corrosion of the metal foils is mainly related to the conservation state of the protecting coatings.

  5. Research in Biological and Medical Sciences Including Biochemistry, Communicable Disease and Immunology, Internal Medicine, Physiology, Psychiatry, Surgery, and Veterinary Medicine. Volume 2

    Science.gov (United States)

    1977-09-01

    expanded portion of a disposable hypodermic syringe container. The resulting hole was smoothed of its rough edges, and glue (Bostick Universal Cement ...unti l monolayer con- fluency was reached in about 5-7 days. Additional medium replacement was usually not necessary. Occasionally, the medium was

  6. Radioactive seed immobilization techniques for interstitial brachytherapy

    International Nuclear Information System (INIS)

    Yan, K.; Podder, T.; Buzurovic, I.; Hu, Y.; Dicker, A.; Valicenti, R.; Yu, Y.; Messing, E.; Rubens, D.; Sarkar, N.; Ng, W.

    2008-01-01

    In prostate brachytherapy, seeds can detach from their deposited sites and move locally in the pelvis or migrate to distant sites including the pulmonary and cardiac regions. Undesirable consequences of seed migration include inadequate dose coverage of the prostate and tissue irradiation effects at the site of migration. Thus, it is clinically important to develop seed immobilization techniques. We first analyze the possible causes for seed movement, and propose three potential techniques for seed immobilization: (1) surgical glue, (2) laser coagulation and (3) diathermy coagulation. The feasibility of each method is explored. Experiments were carried out using fresh bovine livers to investigate the efficacy of seed immobilization using surgical glue. Results have shown that the surgical glue can effectively immobilize the seeds. Evaluation of the radiation dose distribution revealed that the non-immobilized seed movement would change the planned isodose distribution considerably; while by using surgical glue method to immobilize the seeds, the changes were negligible. Prostate brachytherapy seed immobilization is necessary and three alternative mechanisms are promising for addressing this issue. Experiments for exploring the efficacy of the other two proposed methods are ongoing. Devices compatible with the brachytherapy procedure will be designed in future. (orig.)

  7. Dynamics of Pastoralist Relations at Change: An Exploration into the ...

    African Journals Online (AJOL)

    Above all, the marginalization of pastoralists from major political, economic and other considerations, and prejudices attributed to the pastoralist way of life has led to persistent social conflicts. Besides, memories of historical animosities between the Afar and Karrayu ethnic groups served as adhesive glues for the pervasive ...

  8. Baryons and ladders

    International Nuclear Information System (INIS)

    Ball, R.D.

    1990-01-01

    By formal manipulation of the QCD functional integral we arrive at a relativistic low energy effective theory of non-local color singlet mesons and baryons, which at tree level sums up ladders of effective glue exchange between constituent quarks. (orig.)

  9. Renormalisation constants of quark bilinears in lattice QCD with four dynamical Wilson quarks

    NARCIS (Netherlands)

    Blossier, B.; Brinet, M.; Carrasco, N.; Dimopoulos, P.; Du, X.; Frezzotti, R.; Gimenez, V.; Herdoiza, G.; Jansen, K.; Lubicz, V.; Palao, D.; Pallante, E.; Pene, O.; Petrov, K.; Reker, S.; Rossi, G. C.; Sanfilippo, F.; Scorzato, L.; Simula, S.; Urbach, C.

    2011-01-01

    We present preliminary results of the non-perturbative computation of the RI-MOM renormalisation constants in a mass-independent scheme for the action with Iwasaki glue and four dynamical Wilson quarks employed by ETMC. Our project requires dedicated gauge ensembles with four degenerate sea quark

  10. Download this PDF file

    African Journals Online (AJOL)

    Dr.Adesope

    Journal Of Agriculture and Social Research (JASR) Vol. 6, No.2 .... catsup, fragrant flower rice glue ball and other fragrant flower foods were all great creations ... The ancients put some fragrant flower into the rice flour, laid the admixture in a.

  11. 76 FR 45771 - Foreign-Trade Zone 26-Atlanta, GA; Application for Manufacturing Authority; Makita Corporation of...

    Science.gov (United States)

    2011-08-01

    ... bits; socket wrenches; styrene polymers; polyamides; resins; caulk; glues and adhesives; vinyl cases; vinyl tubes; labels; plastic bags; water tanks; plastic grips; rubber knobs and handles; plastic cases... examiner to evaluate and analyze the facts and information presented in the application and case record and...

  12. Lap Shear and Impact Testing of Ochre and Beeswax in Experimental Middle Stone Age Compound Adhesives

    NARCIS (Netherlands)

    Kozowyk, P.R.B.; Langejans, G.; Poulis, J.A.

    2016-01-01

    The production of compound adhesives using disparate ingredients is seen as some of the best evidence of advanced cognition outside of the use of symbolism. Previous field and laboratory testing of adhesives has shown the complexities involved in creating an effective Middle Stone Age glue using

  13. Evaluation of tensile strength of tissue adhesives and sutures for clear corneal incisions using porcine and bovine eyes, with a novel standardized testing platform

    Directory of Open Access Journals (Sweden)

    Kaja S

    2012-02-01

    Full Text Available Simon Kaja, Daryl L Goad, Fatima Ali, Ashley Abraham, R Luke Rebenitsch, Savak Teymoorian, Rohit Krishna, Peter KoulenVision Research Center and Department of Ophthalmology, University of Missouri-Kansas City, School of Medicine, Kansas City, MO, USABackground: Tissue adhesives for ophthalmologic applications were proposed almost 50 years ago, yet to date no adequate tissue glues have been identified that combine strong sealing properties with adequate safety and absence of postsurgical side effects. In recent years, cataract surgeries and Descemet's stripping with endothelial keratoplasty procedures have significantly increased the number of clear corneal incisions performed. One of the obstacles to discovery and development of novel tissue adhesives has been the result of nonstandardized testing of potential tissue glues.Methods: We developed an instrument capable of controlling intraocular pressure in explanted porcine and bovine eyes in order to evaluate sealants, adhesives, and surgical closure methods used in ophthalmic surgery in a controlled, repeatable, and validated fashion. We herein developed and validated our instrument by testing the adhesive properties of cyanoacrylate glue in both porcine and bovine explant eyes.Results: The instrument applied and maintained intraocular pressure through a broad range of physiological intraocular pressures. Cyanoacrylate-based glues showed significantly enhanced sealing properties of clear corneal incisions compared with sutured wounds.Conclusion: This study shows the feasibility of our instrument for reliable and standardized testing of tissue adhesive for ophthalmological surgery.Keywords: manometer, intraocular pressure, applanation tonometry, clear corneal incision, tissue adhesive, ocular surgery

  14. 78 FR 22518 - Request for Information Regarding Third Party Testing for Lead Content, Phthalate Content, and...

    Science.gov (United States)

    2013-04-16

    ...'' refers to composite wood products that are wood-based materials, such as particle board, medium density fiber board, and plywood, consisting largely of natural, untreated wood and glues, adhesives, waxes... ppm; Synthetic food dyes and the presence, if any, or at what levels, of lead. Accessible synthetic...

  15. 75 FR 47482 - National Oil and Hazardous Substance Pollution Contingency Plan; National Priorities List...

    Science.gov (United States)

    2010-08-06

    ... that occurred just prior to extraction of the glue. It was derived primarily from chrome-tanned hides... of concern (COCs) in site media included: arsenic, total chromium and hexavalent [[Page 47485... (except in monitoring well MW-2S). Hexavalent chromium was detected at a low concentration in one of 18...

  16. Bioinspired dopamine-conjugated polyaspartamide as a novel and versatile adhesive material

    Directory of Open Access Journals (Sweden)

    B. Wang

    2017-08-01

    Full Text Available Biomimetic dopamine-conjugated polyaspartamides as novel adhesive materials were synthesized and characterized. These modified polyaspartamides contain three different groups combined with dopamine (DOPA, i.e., γ-amino butyric acid (GABA, ethanolamine (EA and octylamine (OA, which are referred to as PolyAspAm (DOPA/GABA, PolyAspAm(DOPA/EA and PolyAspAm(DOPA/OA, respectively. These three water-swollen polymer glues show good adhesion (0.1~0.4 MPa with various daily-life materials (aluminum foil, glass and paper as well as some plastic substrates (PET and PMMA. Compared to the polymers with more hydrophilic groups (GABA and EA, the polymer glue with the hydrophobic alkyl group (OA exhibited higher adhesive strength values on most substrates. In addition, when applied to biological porcine skin, these glues demonstrated adhesion of values of 15~20 kPa with EA- and OA-conjugated polymers. These results suggest the great potential of dopamine-modified polyaspartamides as versatile and efficient polymeric glues for industrial and biomedical applications.

  17. An Approach Using a 1D Hydraulic Model, Landsat Imaging and Generalized Likelihood Uncertainty Estimation for an Approximation of Flood Discharge

    Directory of Open Access Journals (Sweden)

    Seung Oh Lee

    2013-10-01

    Full Text Available Collection and investigation of flood information are essential to understand the nature of floods, but this has proved difficult in data-poor environments, or in developing or under-developed countries due to economic and technological limitations. The development of remote sensing data, GIS, and modeling techniques have, therefore, proved to be useful tools in the analysis of the nature of floods. Accordingly, this study attempts to estimate a flood discharge using the generalized likelihood uncertainty estimation (GLUE methodology and a 1D hydraulic model, with remote sensing data and topographic data, under the assumed condition that there is no gauge station in the Missouri river, Nebraska, and Wabash River, Indiana, in the United States. The results show that the use of Landsat leads to a better discharge approximation on a large-scale reach than on a small-scale. Discharge approximation using the GLUE depended on the selection of likelihood measures. Consideration of physical conditions in study reaches could, therefore, contribute to an appropriate selection of informal likely measurements. The river discharge assessed by using Landsat image and the GLUE Methodology could be useful in supplementing flood information for flood risk management at a planning level in ungauged basins. However, it should be noted that this approach to the real-time application might be difficult due to the GLUE procedure.

  18. Software : what's in it and what's it in?

    NARCIS (Netherlands)

    Genuchten, van M.J.I.M.; Hatton, L.

    2010-01-01

    Software is the ubiquitous glue of the 21st century. Despite the well-documented difficulties of producing reliable large systems on time and within budget, the amount of software in all kinds of devices is increasing rapidly. For example, the amount of source code in a mobile handset is expected to

  19. ATLAS TileCal Submodule Production Photos (2001)

    CERN Multimedia

    Errede, S.

    2001-01-01

    Photo 1 - Dirty Spacers Photo 2 - Washing Plates Photo 3 - Throw Photo 4 - Catch Photo 5 - Mascot Photo 6 - Glue Machine Photo 7 - Gluing Photo 8 - Finished submodule Photo 9 - Submodule being final welded Photo 10 - Paint tank Photo 11 - Submodule is wrapped Photo 12 - Exhaustion

  20. The Chemo and the Mona: Inhalants, devotion and street youth in Mexico City

    NARCIS (Netherlands)

    Gigengack, R.A.

    2014-01-01

    This paper understands inhalant use – the deliberate inhalation of volatile solvents or glues with intentions of intoxication – as a socially and culturally constituted practice. It describes the inhalant use of young street people in Mexico City from their perspective (“the vicioso or inhalant

  1. Optimization of Performance Parameters for Large Area Silicon Photomultipliers

    Science.gov (United States)

    Janzen, Kathryn

    2008-10-01

    The goal of the GlueX experiment is to search for exotic hybrid mesons as evidence of gluonic excitations in an effort to better understand confinement. A key component of the GlueX detector is the electromagnetic barrel calorimeter (BCAL) located immediately inside a superconducting solenoid of approximately 2.5T. Because of this arrangement, traditional vacuum photomultiplier tubes (PMTs) which are affected significantly by magnetic fields cannot be used on the BCAL. The use of Silicon photomultipliers (SiPMs) as front-end detectors has been proposed. While the largest SiPMs that have been previously employed by other experiments are 1x1 mm^2, GlueX proposes to use large area SiPMs each composed of 16 - 3x3 mm^2 cells in a 4x4 array. This puts the GlueX collaboration in the unique position of driving the technology for larger area sensors. In this talk I will discuss tests done in Regina regarding performance parameters of prototype SiPM arrays delivered by SensL, a photonics research and development company based in Ireland, as well as sample 1x1 mm^2 and 3x3 mm^2 SiPMs.

  2. A Survey of Secondary School Students' Perceptions of and Attitudes Toward Use of Drugs by Teenagers. Part I, Part II, Part III.; A Survey of Secondary School Teachers' Perceptions of the Role of the Schools in Dealing with Teenage Drug Use. A General Overview of Survey Findings.

    Science.gov (United States)

    Montgomery County Public Schools, Rockville, MD.

    Three volumes report the findings of a student survey among a random sample of 2,777 junior high and senior high school students. Volume one presents the overall findings: the typical student believes that drug use and experimentation are not common, except for marihuana, alcohol, cigarettes, and glue; believes that drug use is increasing; is not…

  3. Measurement of heat transfer coefficient using termoanemometry methods

    Science.gov (United States)

    Dančová, P.; Sitek, P.; Vít, T.

    2014-03-01

    This work deals with a measurement of heat transfer from a heated flat plate on which a synthetic jet impacts perpendicularly. Measurement of a heat transfer coefficient (HTC) is carried out using the hot wire anemometry method with glue film probe Dantec 55M47. The paper brings also results of velocity profiles measurements and turbulence intensity calculations.

  4. Measurement of heat transfer coefficient using termoanemometry methods

    Directory of Open Access Journals (Sweden)

    Dančová P.

    2014-03-01

    Full Text Available This work deals with a measurement of heat transfer from a heated flat plate on which a synthetic jet impacts perpendicularly. Measurement of a heat transfer coefficient (HTC is carried out using the hot wire anemometry method with glue film probe Dantec 55M47. The paper brings also results of velocity profiles measurements and turbulence intensity calculations.

  5. 50 Facts about Oral, Head and Neck Cancer

    Science.gov (United States)

    ... Marketplace Find an ENT Doctor Near You 50 Facts about Oral, Head and Neck Cancer 50 Facts about Oral, Head and Neck Cancer Patient Health ... cancer has increased in all races and both sexes. Thyroid cancers account for ... who work in environments with dust, glues, formaldehyde, mustard gas, ...

  6. The glueball trail

    International Nuclear Information System (INIS)

    Roy, P.

    1980-03-01

    The issue of the existence and of the mass values of a new type of unstable hadron composed only of glue, called glueballs (or gluonium), is discussed. Suggested models which could indicate their existence are considered and possible production mechanisms in hadron-hadron collisions and in the decay of heavy quarkonia examined. (UK)

  7. Macromolecular cell surface engineering for accelerated and reversible cellular aggregation.

    OpenAIRE

    Amaral, A. J.; Pasparakis, G.

    2015-01-01

    We report the synthesis of two simple copolymers that induce rapid cell aggregation within minutes in a fully reversible manner. The polymers can act as self-supporting "cellular glues" or as "drivers" of 3D cell spheroids/aggregates formation at minute concentrations.

  8. Bulletin of Materials Science | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    One of the targets was made of pure ZnO powder and the other one consisted of a mixture of ZnO powder with cyanoacrylate glue. The structural and morphological properties of the films obtained using both targets were compared, in order to determine which one produces samples with properties more suitable for their ...

  9. Intravascular Lipiodol Presenting as an Atrial Mass

    NARCIS (Netherlands)

    Kootte, Ruud S.; Haeck, Joost D. E.; van Lienden, Krijn P.; van Boven, Wim J. P.; van der Wal, Allard C.; de Boer, Hans H.

    2017-01-01

    A 68-year-old woman, previously treated with embolization of the thoracic duct with Lipiodol (an ethiodized oil injection) and cyanoacrylate glue (a topical tissue adhesive), was admitted with an asymptomatic mass in the inferior vena cava (IVC) and right atrium. The mass was surgically removed, and

  10. Characteristics of peaks of inhalation exposure to organic solvents

    NARCIS (Netherlands)

    Preller, L.; Burstyn, I.; Pater, N. de; Kromhout, H.

    2004-01-01

    Objectives: To determine which exposure metrics are sufficient to characterize 'peak' inhalation exposure to organic solvents (OS) during spraying operations. Methods: Personal exposure measurements (n = 27; duration 5-159 min) were collected during application of paints, primers, resins and glues

  11. LamLum : a tool for evaluating the financial feasibility of laminated lumber plants

    Science.gov (United States)

    E.M. (Ted) Bilek; John F. Hunt

    2006-01-01

    A spreadsheet-based computer program called LamLum was created to analyze the economics of value- added laminated lumber manufacturing facilities. Such facilities manufacture laminations, typically from lower grades of structural lumber, then glue these laminations together to make various types of higher value laminated lumber products. This report provides the...

  12. Contingency Pest and Vector Surveillance

    Science.gov (United States)

    2013-11-01

    while pulling the tick drag by wrapping masking tape, sticky-side out, around the pant legs in one or two places (above the ankle and above the...close quarters with people. Use a large glue surface, and the board must be anchored to the floor to prevent the snake from carrying it off. Place

  13. 25 CFR 11.451 - Abuse of psychotoxic chemical solvents.

    Science.gov (United States)

    2010-04-01

    ... use the solvent in violation of this section. (b) This section does not apply to inhalation of... any glue, gasoline, paint, hair spray, Lysol, or other substance containing one or more of the...) Peptone; (7) Pentachlorophenol; (8) Petroleum ether; or (9) Any other chemical substance the inhalation of...

  14. Primary ethmoid sinus squamous cell carcinoma in a young adult man

    African Journals Online (AJOL)

    life.[2] Environmental exposures to wood and leather dust, as well as glues, formaldehyde, nickel and chrome, are strongly associated with the development of some ... radiation and cycles of chemotherapy. Discussion. Primary ethmoid SNSCCs make up 5 - 25% of all sinus malignan cies.[10] The literature is deficient on ...

  15. Factor and Remainder Theorems: An Appreciation

    Science.gov (United States)

    Weiss, Michael

    2016-01-01

    The high school curriculum sometimes seems like a disconnected collection of topics and techniques. Theorems like the factor theorem and the remainder theorem can play an important role as a conceptual "glue" that holds the curriculum together. These two theorems establish the connection between the factors of a polynomial, the solutions…

  16. Surgical adhesives in ophthalmology: history and current trends.

    Science.gov (United States)

    Guhan, Samantha; Peng, Si-Liang; Janbatian, Hrag; Saadeh, Stephanie; Greenstein, Stephen; Al Bahrani, Faisal; Fadlallah, Ali; Yeh, Tsai-Chu; Melki, Samir A

    2018-03-26

    Tissue adhesives are gaining popularity in ophthalmology, as they could potentially reduce the complications associated with current surgical methods. An ideal tissue adhesive should have superior tensile strength, be non-toxic and anti-inflammatory, improve efficiency and be cost-effective. Both synthetic and biological glues are available. The primary synthetic glues include cyanoacrylate and the recently introduced polyethylene glycol (PEG) derivatives, while most biological glues are composed of fibrin. Cyanoacrylate has a high tensile strength, but rapidly polymerises upon contact with any fluid and has been associated with histotoxicity. Fibrin induces less toxic and inflammatory reactions, and its polymerisation time can be controlled. Tensile strength studies have shown that fibrin is not as strong as cyanoacrylate. While more research is needed, PEG variants currently appear to have the most promise. These glues are non-toxic, strong and time-effective. Through MEDLINE and internet searches, this paper presents a systematic review of the current applications of surgical adhesives to corneal, glaucoma, retinal, cataract and strabismus surgeries. Our review suggests that surgical adhesives have promise to reduce problems in current ophthalmic surgical procedures. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. Journal of Genetics | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    In the present study, these X-linked markers have been employed to trace the pattern of introgression of D. n. nasuta and D. n. albomicans genomes with respect to the major glue protein fractions in their interracial hybrids, called cytoraces. These cytoraces have inherited the chromosomes of both parents and have been ...

  18. QCD inspired bag model of quarkonium

    International Nuclear Information System (INIS)

    Hasenfratz, P.; Horgan, R.R.; Kuti, J.; Richard, J.M.

    1981-01-01

    The QCD motivated bag model is applied to heavy quark-antiquark systems. The effect of colored glue in the model is shown to explain the rapid cross-over of the static QQ potential from the asymptotically free Coulomb region into the linear confinement regime. The spin-dependent force between static quarks is derived in Coulomb gauge from the exchange of a confined transverse gluon. The dimensional bag parameter Λ/sub B/ = 235 MeV and the quark-gluon coupling constant α = 0.38 as defined at r/sub QQ/approx.0.2 fermi are determined from a good fit of the cc-bar and bb-bar spectra. The fit is in serious disagreement with the widely accepted MIT parameters. As an important test of our model, we calculate the rich spectrum of QQ glue states. In UPSILON particle spectroscopy we predict a narrow QQ glue state with exotic quantum numbers J/sup PC/ = 1 -+ below the BB threshold. Its experimental confirmation would be the first direct evidence for colored glue in the hadron spectrum

  19. Balanced Can

    Science.gov (United States)

    Shakerin, Said

    2013-01-01

    The ordinary 12-oz beverage cans in the figures below are not held up with any props or glue. The bottom of such cans is stepped at its circumference for better stacking. When this kind of can is tilted, as shown in Fig. 1, the outside corners of the step touch the surface beneath, providing an effective contact about 1 cm wide. Because the…

  20. 24 CFR 3280.203 - Flame spread limitations and fire protection requirements.

    Science.gov (United States)

    2010-04-01

    ... value shown in § 3280.203(b) when tested by Standard Test Method for Surface Burning Characteristics of Building Materials, ASTM E84-01, 2001, or Standard Method of Test of Surface Burning Characteristics of... plastic panel countertop; (ii) 1/4-inch or thicker unfinished plywood with phenolic or urea glue; (iii...

  1. The Orange Feeling

    DEFF Research Database (Denmark)

    Kiib, Hans; Kiib, Birgitte Marling; Jespersen, Line Marie Bruun

    2017-01-01

    on the specific atmosphere and on how the designs support this. It concludes that the culture of laughter is the atmospheric glue that keeps Roskilde Festival together, and it is the performative and relational designs together with the culture of laughter that create the basis for ‘The Orange Feeling’....

  2. Minimizing and predicting delamination of southern plywood in exterior exposure

    Science.gov (United States)

    Peter Koch

    1967-01-01

    Southern pine plywood is substantially all being manufactured with phenolic glue for exterior use. Because panels must not delaminate in service, a reliable predictor of glueline durability is required. Drawing on the experience of the Douglas-fir plywood industry, southern manufacutrers have adopted as a predictor the percentage of wood failure(% WF) observed in...

  3. Performance of a rigid and a flexible adhesive in lumber joints subjected to moisture content changes

    Science.gov (United States)

    G. P. Krueger; R. F. Blomquist

    1964-01-01

    Experimental work was undertaken to investigate the extent and magnitude of deterioration that can occur in typical plywood-to-lumber glue joints subjected to stresses resulting from changes in the moisture content of the wood, and to compare the performance of a somewhat flexible or deformable adhesive to that of a rigid adhesive in these joints. Results showed that...

  4. Converting lignin to aromatics: step by step

    NARCIS (Netherlands)

    Strassberger, Z.I.

    2014-01-01

    Lignin, the glue that holds trees together, is the most abundant natural resource of aromatics. In that respect, it is a far more advanced resource than crude oil. This is because lignin already contains the aromatic functional groups. Thus, catalytic conversion of lignin to high-value aromatics is

  5. Laser ablation of a biliary duct for treatment of a persistent biliary-cutaneous fistula.

    Science.gov (United States)

    Eicher, Chad A; Adelson, Anthony B; Himmelberg, Jeffrey A; Chintalapudi, Udaya

    2008-02-01

    A persistent biliary-cutaneous fistula detected after biliary drainage catheter removal could not be resolved with diversionary techniques and Gelfoam and fibrin glue administration in the fistulous tract. As an alternative approach for treatment of the fistula, obliteration of the contributing bile duct with laser ablation was performed.

  6. Merits and Perils of Teaching about Other Cultures.

    Science.gov (United States)

    McDougall, Walter A.

    2000-01-01

    Suggest that it is important for students to be taught about multi-cultural history, but in order to ensure that multi-cultural education is a glue, rather than a solvent, of U.S. community, there must be dedicated, knowledgeable, and honest teaching that reveals to students the ways in which all human beings are alike. (SM)

  7. Enterocutaneous fistula: A review of 82 cases | Njeze | Nigerian ...

    African Journals Online (AJOL)

    After treatment for correction of fluid and electrolyte deficits, they were all tried on conservative therapy with enteral nutritional support as the main stay of management. Those, whose fistulas did not close, underwent surgical treatment. Total parenteral nutrition, octreotide, fibrin glue, and wound vacuum assisted closure ...

  8. How to Preserve Photographic Artworks for the Future : Chemical and Physical Interactions and Implications for Conservation Strategies

    NARCIS (Netherlands)

    Reijers, E.B.

    2017-01-01

    The combination of photographic prints with additional materials such as paints, varnishes, glues, etc. has given rise to a new type of artworks known as photoworks or photographic art. These photoworks have become a important part of our cultural heritage, and are being recognised as contemporary

  9. Lined canvas paintings

    DEFF Research Database (Denmark)

    Krarup Andersen, Cecil

    2013-01-01

    at 50% RH but increased the stress level severely in dry conditions and offered no support to the painting at 70-80 % RH. This means that the traditional glue-paste lining techniques and the wax-resin technique in high RH seem to limit the advisable RH fluctuation in a cultural institution. Conversely...

  10. Using Art to Teach Children about Themselves and the World

    Science.gov (United States)

    Belz, Paul

    2011-01-01

    Teachers know about the joyful discoveries children make when they create animal masks, draw with a handful of crayons, use spices mixed with glue to paint a self-portrait, or compare their colorful fingerprints. Art activities fit beautifully with early childhood education's emphasis on social, emotional, cognitive, and physical learning…

  11. How to: understanding SWAT model uncertainty relative to measured results

    Science.gov (United States)

    Watershed models are being relied upon to contribute to most policy-making decisions of watershed management, and the demand for an accurate accounting of complete model uncertainty is rising. Generalized likelihood uncertainty estimation (GLUE) is a widely used method for quantifying uncertainty i...

  12. In situ cytokine analysis in human contact dermatitis : implications for a differentiation marker and an ex vivo human contact dermatitis model

    NARCIS (Netherlands)

    S. Hoefakker (Saskia)

    1995-01-01

    textabstractOur skin is under constant environmental stress resulting from personal care (soap, cosmetics, clothes), home (plants, wood, vegetables), leisure (glues, photodevelopers, paints) and work. Although the skin is an efficient barrier and body protector a cutaneous disorder may be induced by

  13. D. McKenzie, C. Miller and D.A. Falk, eds. The Landscape Ecology of Fire [book review

    Science.gov (United States)

    Eric J. Gustafson

    2012-01-01

    In the Foreword of this volume is the statement that "landscape ecology is the 'glue' that holds ecosystem theory together and nowhere is that more evident than in the study of wildland fire ecology." The Landscape Ecology of Fire summarizes how landscape ecology has contributed to, and been formed by, the study...

  14. Ocular aids: experience at the Guinness Ophthalmic unit,Kaduna

    African Journals Online (AJOL)

    .

    cyanoacrylate glue and bandage contact lens which is simple, non-surgical, and convenient but unavailable. ... spontaneously occurring non-healing ulcer of the left lower lid margin and medial canthus.A 38 year old ... urea, blood pressure measurement and HIV I & II testing with subsequent referral to the STI/HIV clinic.

  15. Danish Hernia Database recommendations for the management of inguinal and femoral hernia in adults

    DEFF Research Database (Denmark)

    Rosenberg, Jacob; Bisgaard, Thue; Kehlet, Henrik

    2011-01-01

    a mesh secured with a nonabsorbable monofilament suture. In laparoscopic repair a mesh without a slit and with a minimum size of 15 by 10 cm is used. For mesh fixation absorbable or nonabsorbable tacks or glue can be used. Elective surgery for groin hernia should be performed in an outpatient setting...

  16. Arthropods of native and exotic vegetation and their association with willow flycatchers and Wilson's warblers

    Science.gov (United States)

    Linda S. DeLay; Deborah M. Finch; Sandra Brantley; Richard Fagerlund; Michael D. Means; Jeffrey F. Kelly

    1999-01-01

    We compared abundance of migrating Willow Flycatchers and Wilson's Warblers to the abundance of arthropods in exotic and native vegetation at Bosque del Apache National Wildlife Refuge. We trapped arthropods using glue-boards in 1996 and 1997 in the same cottonwood, saltcedar, and willow habitats where we mist-netted birds during spring and fall migration. There...

  17. The paradox of high shear granulation : the formation of non-homogeneous granules

    NARCIS (Netherlands)

    Dries, Kaspar van den

    2004-01-01

    Wet granulation is a process used for the particle size enlargement of primary powders. The mixing of a liquid with the powder glues the primary particles together, which results in the formation of the granules. The mixing action can be performed in many ways, like tumbling (drum granulation),

  18. Express-Air Screen-System to protect miners against radon exposures at small underground construction sites in old mining; Express-Wetterblenden-System zum Sofort-Schutz von Bergleuten vor Radonexpositionen bei untertaegigen Bergsicherungsarbeiten im Altbergbau

    Energy Technology Data Exchange (ETDEWEB)

    Dehnert, J. [Saechsisches Landesamt fuer Umwelt, Landwirtschaft und Geologie (Germany). Referat Strahlenschutz; Stopp, J. [Aluminiumbau und Verwaltungs GmbH Stopp, Schneeberg (Germany); Schoenherr, B. [Bergsicherung Schneeberg GmbH (Germany)

    2016-07-01

    A new Express-Air Screen-System (EAS) for miners was developed to reduce the radon exposures of miners at small construction sites of old mining. The EAS is a lightweight, modular and reusable construction kit of interlocking telescopic aluminum tubes, plastic foils and glue foam to shut off radon rich parts of galleries in some minutes only.

  19. EFEITO DO TRATAMENTO TÉRMICO SOBRE A RESISTÊNCIA AO CISALHAMENTO DA LINHA DE COLA EM PAINÉIS OSB

    Directory of Open Access Journals (Sweden)

    Airton Mauro de Lára Santos

    2009-01-01

    Full Text Available Research to improve dimensional stability of oriented strand boards (OSB through thermal treatment has been done. It aims to reduce the higroscopicity of the wood particles as well as to relieve the compression stresses generated during pressing process. In spite of the advantages, the thermal treatment above 160ºC can inactive the surface of the wood, reducing the penetration of the adhesive and, this way, reducing the quality of the adhesion. The sanding of the surface of OSB panels can remove this effect, increasing the quality of the adhesion and the glue line strength. The present study aimed to evaluate the effect of the thermal treatment on the glue-line shear strength of OSB panels and the effect of the sanding process on this strength, as well. Commercial OSB were thermally treated according to two temperature levels (190 and 220ºC, three times (12, 16 and 20 minutes. Eighty-four samples were cut, both of them were sanded before the gluing (resorcinol-formaldehyde, 360 g/m². The glue-line shear strength testing was conducted according to ASTM D 1037 standard. The results reveled that the proposed thermal treatment reduced slightly the shear strength The interaction factor between temperature and time on these results wasidentified. However, sanding process removed this effect and improved significantly shear strength. Therefore, the thermical treatment imparted little effect on the glue-line shear strength, while the sanding process improved the quality of the adhesion in OSB panels.

  20. The chemo and the mona : Inhalants, devotion and street youth in Mexico city

    NARCIS (Netherlands)

    Gigengack, Roy

    This paper understands inhalant use - the deliberate inhalation of volatile solvents or glues with intentions of intoxication - as a socially and culturally constituted practice. It describes the inhalant use of young street people in Mexico City from their perspective ("the vicioso or inhalant

  1. Study of n-on-p sensors breakdown in presence of dielectrics placed on top surface

    CERN Document Server

    Helling, Cole Michael; The ATLAS collaboration

    2018-01-01

    The ATLAS Upgrade strip module design has readout flex circuits glued directly on top of the sensors’ active area to facilitate the assembly process and minimize the radiation length. The process requires radiation-hard adhesives compatible with the sensor technology. We report on the studies of the breakdown behavior with miniature versions of the prototype sensors, where candidate adhesives were placed in several locations on top of the sensor, including the strip area, guard ring region, and sensor edge. Thermal cycling tends to attenuate the observed cases of breakdown with glue on top of the guard ring. Glue reaching the sensor edge results in low breakdown voltage if it also covers AC- or DC- pads or bias ring openings. Glue placement on top of guard ring region was performed on a large-format sensor, with generally similar results to the miniature sensor tests, except for a large glue deposition, which resulted in a permanent reduction of the breakdown voltage. Post-irradiation measurements were perf...

  2. Plaquette-plaquette correlations in the SU(2) lattice gauge theory

    International Nuclear Information System (INIS)

    Berg, B.

    1980-09-01

    Monte Carlo measurements of plaquette-plaquette correlations in the 4-dimensional SU(2) lattice gauge theory are reported. For low temperatures the glue ball mass (= inverse correlation length) is estimated to be msub(g) = (3.7 +- 1.2) √K, where K is the string tension. (orig.)

  3. The social impact of sport: cross-cultural perspectives

    NARCIS (Netherlands)

    Spaaij, R.

    2011-01-01

    1. Introduction: The Social Impact of Sport: Diversities, Complexities and Contexts Ramon Spaaij Part 1: Sport development and social change: intended and unanticipated consequences 2. The Transnational View of Sport and Social Development: The Case of Dominican Baseball Alan Klein 3. The Glue that

  4. Bilateral spontaneous in-the-bag anterior subluxation of PCIOL managed with glued IOL technique: A case report.

    Science.gov (United States)

    Nair, Vidya; Kumar, Dhivya Ashok; Prakash, Gaurav; Jacob, Soosan; Agarwal, Athiya; Agarwal, Amar

    2009-07-01

    Management of in-the-bag spontaneous bilateral subluxation of posterior-chamber intraocular lens(PCIOL) with sutureless fibrin-glue-assisted PCIOL implantation. A patient of retinitis pigmentosa with spontaneous bilateral anterior in-the-bag subluxation of PCIOL was managed by IOL explantation followed by fibrin-glue-assisted sutureless PCIOL implantation. Two partial thickness limbal-based scleral flaps were created about 1.5 mm from the limbus under which sclerotomies were made. Intraocular lens explantation along with capsular bag was performed through the corneo-scleral tunnel incision. Single-piece rigid polymethylmethacrylate 6.5-mm optic IOL was introduced through the limbal wound with a McPherson forceps, both the IOL haptics were externalized under the scleral flap. The haptic ends were tucked in the scleral tunnel made with the 26G needle. Scleral flaps and the conjunctiva were closed with the fibrin glue. Preoperative best corrected visual acuity was 20/80 in the right and 20/120 in the left eye. Patient gained a best corrected visual acuity of 20/30 in both the eyes, with a bilateral stable PCIOL and clear cornea. Severe capsular contracture causing in-the-bag IOL subluxation in retinitis pigmentosa can be effectively managed with this new technique of sutureless fibrin-glue-assisted PCIOL implantation.

  5. Moisture meter calibrations for untreated and ACQ-treated southern yellow pine lumber and plywood

    Science.gov (United States)

    C.R. Boardman; Samuel V. Glass; Charles G. Carll

    2011-01-01

    This study investigates the effects of alkaline copper quaternary (ACQ) preservative treatment and of plywood glue lines on resistance-based moisture content (MC) measurements. Moisture meter readings using stainless steel screws as electrodes were acquired over a range of moisture conditions in Southern Yellow Pine (SYP) lumber and plywood. Calibration equations are...

  6. Wafer-scale fabrication of glass-FEP-glass microfluidic devices for lipid bilayer experiments

    NARCIS (Netherlands)

    Bomer, Johan G.; Prokofyev, A.V.; van den Berg, Albert; le Gac, Severine

    2014-01-01

    We report a wafer-scale fabrication process for the production of glass-FEP-glass microdevices using UV-curable adhesive (NOA81) as gluing material, which is applied using a novel "spin & roll" approach. Devices are characterized for the uniformity of the gluing layer, presence of glue in the

  7. A novel bio-inorganic bone implant containing deglued bone

    Indian Academy of Sciences (India)

    With the aim of developing an ideal bone graft, a new bone grafting material was developed using deglued bone, chitosan and gelatin. Deglued bone (DGB) which is a by-product of bone glue industries and has the close crystallographic similarities of hydroxyapatite was used as main component in the preparation of bone ...

  8. How methylhydroxyethylcellulose (MHEC) influences drying in porous media

    NARCIS (Netherlands)

    Faiyas, A.P.A.; Erich, S.J.F.; van Soestbergen, M.; Huinink, H.P.; Adan, O.C.G.; Nijland, T.G.

    2015-01-01

    This article presents both an experimental as well as a theoretical study on the effect of MethylHydroxyEthylCellulose (MHEC) on drying in porous materials using Nuclear Magnetic Resonance Imaging (NMR). MHEC, a water soluble polymer, is normally added to glue mortars as a water retention agent in

  9. Radiation treatment of materials - elaboration bases of radiation technology; Obrobka radiacyjna materialow - zasady opracowywania technologii

    Energy Technology Data Exchange (ETDEWEB)

    Panta, P P [Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    1997-10-01

    The basic rules in design of radiation technologies have been presented and discussed. The recommendations for achieving of assigned goal in respect of obliged regulations have been done and explained on the example of radiation technology of adhesive materials and glue production.

  10. Some properties of LVL composed of poplar and beech veneer and possibilities of their application for window frames

    Directory of Open Access Journals (Sweden)

    Zdravković Vladislav

    2017-01-01

    Full Text Available The subject of this paper was a research of physical and mechanical properties of LVL composed of peeled poplar veneers in core layers and only outer layers of beech peeled veneers, so as the examination of window frame glue joint strength produced of this material. LVL boards have been hot pressed in industrial conditions, using appropriate phenol formaldehyde (PP adhesive. Samples for corner window frame glue joint strength testing were glued with PVAc D4 class adhesive. Statistical analysis showed that there were significant differences both in moisture content and density of LVL boards regarding their thickness, while in the case of hardness this difference did not exist. Examinations of LVL glue line shear strength showed that both phenol formaldehyde (PP and PVAc D4 class adhesives fulfilled standard requirements. The results of corner window frame double tenon glue joint strength produced from combined poplar-beech veneer LVL indicated that such material could be used to produce window frame corner joint, strong enough to withstand the additional load, without an increase of the cross section.

  11. Face Time

    Science.gov (United States)

    Waters, John K.

    2008-01-01

    It was the perfect Halloween project. Each class would construct a three-dimensional "monster" out of common classroom materials (construction paper, cardboard boxes, tape, markers, glue, string, etc.), then write down instructions for building the monster and send them off to another class in the district, or in some other district, or even some…

  12. Tests of the wire ageing induced by radiation in the barrel muon chambers of the CMS experiment at LHC

    International Nuclear Information System (INIS)

    Conti, E.; Ballarini, R.; Gasparine, F.

    1999-01-01

    In CMS the barrel muon detectors are drift tubes (DT) filled with Ar/CO 2 gas. Materials of the DT in contact with the gas can outgas pollutant substances during irradiation which may cause a loss of gain or a worsening of the time resolution (wire ageing) during the multiplication process. This article presents the laboratory tests performed to verify that the materials used in DT do not induce wire ageing. The tests concern all the materials inside the DT which are in contact with the gas: 1) mylar tape with glue based on reticulated silicon polymers, 2) Al tape with mono-acrylic glue, 3) bare FR4 boards for HV, and 4) complete FR4 boards for HV (with cables, resistors, capacitors and glue). Both Al and mylar are known to be safe from the point of view of ageing, so the tests concern essentially the glues. For all the above materials, the result is negative, it means that no change of the wire gain has been measured within a few percents which is the sensitivity of the apparatus. (A.C.)

  13. West Europe Report, No. 2174.

    Science.gov (United States)

    1983-07-15

    and inks , 4 billion for acrylics, adhesives, glues, etc.). Finally, the contract places emphasis on the foreign trade balance. This means that CDF...cafe he took a white napkin and drew a large circle and a smaller circle. They represented social democracy and communism. Then Hermansson drew a

  14. Baryons and QCD

    International Nuclear Information System (INIS)

    Nathan Isgur

    1997-01-01

    The author presents an idiosyncratic view of baryons which calls for a marriage between quark-based and hadronic models of QCD. He advocates a treatment based on valence quark plus glue dominance of hadron structure, with the sea of q pairs (in the form of virtual hadron pairs) as important corrections

  15. Neutrino astronomy: Present and future

    Indian Academy of Sciences (India)

    Abstract. I briefly review the present and future status of the burgeoning field of neu- ... near future build upon previous results. ... novel radio and acoustic techniques utilized by, for example, experiments such as. GLUE ... Left: Schematic of νµ-induced muon track in detector. Right: .... an eye toward the galactic center).

  16. A novel ecdysone receptor mediates steroid-regulated developmental events during the mid-third instar of Drosophila.

    Directory of Open Access Journals (Sweden)

    Benjamin F B Costantino

    2008-06-01

    Full Text Available The larval salivary gland of Drosophila melanogaster synthesizes and secretes glue glycoproteins that cement developing animals to a solid surface during metamorphosis. The steroid hormone 20-hydroxyecdysone (20E is an essential signaling molecule that modulates most of the physiological functions of the larval gland. At the end of larval development, it is known that 20E--signaling through a nuclear receptor heterodimer consisting of EcR and USP--induces the early and late puffing cascade of the polytene chromosomes and causes the exocytosis of stored glue granules into the lumen of the gland. It has also been reported that an earlier pulse of hormone induces the temporally and spatially specific transcriptional activation of the glue genes; however, the receptor responsible for triggering this response has not been characterized. Here we show that the coordinated expression of the glue genes midway through the third instar is mediated by 20E acting to induce genes of the Broad Complex (BRC through a receptor that is not an EcR/USP heterodimer. This result is novel because it demonstrates for the first time that at least some 20E-mediated, mid-larval, developmental responses are controlled by an uncharacterized receptor that does not contain an RXR-like component.

  17. Sticky traps saturate with navel orangeworm in a non-linear fashion

    Science.gov (United States)

    In order to evaluate saturation thresholds as well as differences among wing-trap types, we used unmated female navel orangeworm (NOW) as sex pheromone baits in wing-traps that varied by color and glue/trapping surface. These results were compared to male capture in red delta and simple water cup tr...

  18. Technical Note: Thoracic duct embolization for treatment of chylothorax: A novel guidance technique for puncture using combined MRI and fluoroscopy

    International Nuclear Information System (INIS)

    Praveen, Alampath; Sreekumar, Karumathil Pullara; Nazar, Puthukudiyil Kader; Moorthy, Srikanth

    2012-01-01

    Thoracic duct embolization (TDE) is an established radiological interventional procedure for thoracic duct injuries. Traditionally, it is done under fluoroscopic guidance after opacifying the thoracic duct with bipedal lymphangiography. We describe our experience in usinga heavily T2W sequence for guiding thoracic duct puncture and direct injection of glue through the puncture needle without cannulating the duct

  19. Technical Note: Thoracic duct embolization for treatment of chylothorax: A novel guidance technique for puncture using combined MRI and fluoroscopy.

    Science.gov (United States)

    Praveen, Alampath; Sreekumar, Karumathil Pullara; Nazar, Puthukudiyil Kader; Moorthy, Srikanth

    2012-04-01

    Thoracic duct embolization (TDE) is an established radiological interventional procedure for thoracic duct injuries. Traditionally, it is done under fluoroscopic guidance after opacifying the thoracic duct with bipedal lymphangiography. We describe our experience in usinga heavily T2W sequence for guiding thoracic duct puncture and direct injection of glue through the puncture needle without cannulating the duct.

  20. 76 FR 39095 - Compatibility of Underground Storage Tank Systems With Biofuel Blends

    Science.gov (United States)

    2011-07-05

    ... recovery equipment because these components do not routinely contain liquid product. Incompatibility of... commenters' input, EPA is removing from the list pipe adhesives and glues, because these components are..., an UST contractor installing a new UST system does not have discretion over which pipe adhesives to...