WorldWideScience

Sample records for glucose concentration measured

  1. Evanescent Wave Absorption Based Fiber Sensor for Measuring Glucose Solution Concentration

    Science.gov (United States)

    Marzuki, Ahmad; Candra Pratiwi, Arni; Suryanti, Venty

    2018-03-01

    An optical fiber sensor based on evanescent wave absorption designed for measuring glucose solution consentration was proposed. The sensor was made to detect absorbance of various wavelength in the glucose solution. The sensing element was fabricated by side polishing of multimode polymer optical fiber to form a D-shape. The sensing element was immersed in different concentration of glucoce solution. As light propagated through the optical fiber, the evanescent wave interacted with the glucose solution. Light was absorbed by the glucose solution. The larger concentration the glucose solution has, the more the evanescent wave was absorbed in particular wavelenght. Here in this paper, light absorbtion as function of glucose concentration was measured as function of wavelength (the color of LED). We have shown that the proposed sensor can demonstrated an increase of light absorption as function of glucose concentration.

  2. Differential Mueller matrix polarimetry technique for non-invasive measurement of glucose concentration on human fingertip.

    Science.gov (United States)

    Phan, Quoc-Hung; Lo, Yu-Lung

    2017-06-26

    A differential Mueller matrix polarimetry technique is proposed for obtaining non-invasive (NI) measurements of the glucose concentration on the human fingertip. The feasibility of the proposed method is demonstrated by detecting the optical rotation angle and depolarization index of tissue phantom samples containing de-ionized water (DI), glucose solutions with concentrations ranging from 0~500 mg/dL and 2% lipofundin. The results show that the extracted optical rotation angle increases linearly with an increasing glucose concentration, while the depolarization index decreases. The practical applicability of the proposed method is demonstrated by measuring the optical rotation angle and depolarization index properties of the human fingertips of healthy volunteers.

  3. Noninvasive measurement of glucose concentration on human fingertip by optical coherence tomography

    Science.gov (United States)

    Chen, Tseng-Lin; Lo, Yu-Lung; Liao, Chia-Chi; Phan, Quoc-Hung

    2018-04-01

    A method is proposed for determining the glucose concentration on the human fingertip by extracting two optical parameters, namely the optical rotation angle and the depolarization index, using a Mueller optical coherence tomography technique and a genetic algorithm. The feasibility of the proposed method is demonstrated by measuring the optical rotation angle and depolarization index of aqueous glucose solutions with low and high scattering, respectively. It is shown that for both solutions, the optical rotation angle and depolarization index vary approximately linearly with the glucose concentration. As a result, the ability of the proposed method to obtain the glucose concentration by means of just two optical parameters is confirmed. The practical applicability of the proposed technique is demonstrated by measuring the optical rotation angle and depolarization index on the human fingertip of healthy volunteers under various glucose conditions.

  4. Hydrogen peroxide and glucose concentration measurement using optical fiber grating sensors with corrodible plasmonic nanocoatings.

    Science.gov (United States)

    Zhang, Xuejun; Wu, Ze; Liu, Fu; Fu, Qiangqiang; Chen, Xiaoyong; Xu, Jian; Zhang, Zhaochuan; Huang, Yunyun; Tang, Yong; Guo, Tuan; Albert, Jacques

    2018-04-01

    We propose and demonstrate hydrogen peroxide (H 2 O 2 ) and glucose concentration measurements using a plasmonic optical fiber sensor. The sensor utilizes a tilted fiber Bragg grating (TFBG) written in standard single mode communication fiber. The fiber is over coated with an nm-scale film of silver that supports surface plasmon resonances (SPRs). Such a tilted grating SPR structure provides a high density of narrow spectral resonances (Q-factor about 10 5 ) that overlap with the broader absorption band of the surface plasmon waves in the silver film, thereby providing an accurate tool to measure small shifts of the plasmon resonance frequencies. The H 2 O 2 to be detected acts as an oxidant to etch the silver film, which has the effect of gradually decreasing the SPR attenuation. The etching rate of the silver film shows a clear relationship with the H 2 O 2 concentration so that monitoring the progressively increasing attenuation of a selected surface plasmon resonance over a few minutes enables us to measure the H 2 O 2 concentration with a limit of detection of 0.2 μM. Furthermore, the proposed method can be applied to the determination of glucose in human serum for a concentration range from 0 to 12 mM (within the physiological range of 3-8 mM) by monitoring the H 2 O 2 produced by an enzymatic oxidation process. The sensor does not require accurate temperature control because of the inherent temperature insensitivity of TFBG devices referenced to the core mode resonance. A gold mirror coated on the fiber allows the sensor to work in reflection, which will facilitate the integration of the sensor with a hypodermic needle for in vitro measurements. The present study shows that Ag-coated TFBG-SPR can be applied as a promising type of sensing probe for optical detection of H 2 O 2 and glucose detection in human serum.

  5. Hydrogen peroxide and glucose concentration measurement using optical fiber grating sensors with corrodible plasmonic nanocoatings

    Science.gov (United States)

    Zhang, Xuejun; Wu, Ze; Liu, Fu; Fu, Qiangqiang; Chen, Xiaoyong; Xu, Jian; Zhang, Zhaochuan; Huang, Yunyun; Tang, Yong; Guo, Tuan; Albert, Jacques

    2018-01-01

    We propose and demonstrate hydrogen peroxide (H2O2) and glucose concentration measurements using a plasmonic optical fiber sensor. The sensor utilizes a tilted fiber Bragg grating (TFBG) written in standard single mode communication fiber. The fiber is over coated with an nm-scale film of silver that supports surface plasmon resonances (SPRs). Such a tilted grating SPR structure provides a high density of narrow spectral resonances (Q-factor about 105) that overlap with the broader absorption band of the surface plasmon waves in the silver film, thereby providing an accurate tool to measure small shifts of the plasmon resonance frequencies. The H2O2 to be detected acts as an oxidant to etch the silver film, which has the effect of gradually decreasing the SPR attenuation. The etching rate of the silver film shows a clear relationship with the H2O2 concentration so that monitoring the progressively increasing attenuation of a selected surface plasmon resonance over a few minutes enables us to measure the H2O2 concentration with a limit of detection of 0.2 μM. Furthermore, the proposed method can be applied to the determination of glucose in human serum for a concentration range from 0 to 12 mM (within the physiological range of 3-8 mM) by monitoring the H2O2 produced by an enzymatic oxidation process. The sensor does not require accurate temperature control because of the inherent temperature insensitivity of TFBG devices referenced to the core mode resonance. A gold mirror coated on the fiber allows the sensor to work in reflection, which will facilitate the integration of the sensor with a hypodermic needle for in vitro measurements. The present study shows that Ag-coated TFBG-SPR can be applied as a promising type of sensing probe for optical detection of H2O2 and glucose detection in human serum. PMID:29675315

  6. Study on the mechanism of human blood glucose concentration measuring using mid-infrared spectral analysis technology

    Science.gov (United States)

    Li, Xiang

    2016-10-01

    All forms of diabetes increase the risk of long-term complications. Blood glucose monitoring is of great importance for controlling diabetes procedure, preventing the complications and improving the patient's life quality. At present, the clinical blood glucose concentration measurement is invasive and could be replaced by noninvasive spectroscopy analytical techniques. The mid-infrared spectral region contains strong characteristic and well-defined absorption bands. Therefore, mid-infrared provides an opportunity for monitoring blood glucose invasively with only a few discrete bonds. Although the blood glucose concentration measurement using mid-infrared spectroscopy has a lot of advantages, the disadvantage is also obvious. The absorption in this infrared region is fundamental molecular group vibration. Absorption intensity is very strong, especially for biological molecules. In this paper, it figures out that the osmosis rate of glucose has a certain relationship with the blood glucose concentration. Therefore, blood glucose concentration could be measured indirectly by measuring the glucose exudate in epidermis layer. Human oral glucose tolerance tests were carried out to verify the correlation of glucose exudation in shallow layer of epidermis layer and blood glucose concentration. As it has been explained above, the mid-infrared spectral region contains well-defined absorption bands, the intensity of absorption peak around 1123 cm-1 was selected to measure the glucose and that around 1170 cm-1 was selected as reference. Ratio of absorption peak intensity was recorded for each set of measurement. The effect and importance of the cleaning the finger to be measured before spectrum measuring are discussed and also verified by experiment.

  7. Correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer and serum glucose concentration measured by an automated biochemical analyzer for canine and feline blood samples.

    Science.gov (United States)

    Tauk, Barbara S; Drobatz, Kenneth J; Wallace, Koranda A; Hess, Rebecka S

    2015-06-15

    To investigate the correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer (POCG) and serum glucose concentration measured by a biochemical analyzer. Prospective clinical study. 96 blood samples from 80 dogs and 90 blood samples from 65 cats. Serum, plasma, and whole blood were obtained from each blood sample. The glucose concentrations in serum, plasma, and whole blood measured by a POCG were compared with the serum glucose concentration measured by a biochemical analyzer by use of the Lin concordance correlation coefficient (ρc) and Bland-Altman plots. For both canine and feline samples, glucose concentrations in serum and plasma measured by the POCG were more strongly correlated with the serum glucose concentration measured by the biochemical analyzer (ρc, 0.98 for both canine serum and plasma; ρc, 0.99 for both feline serum and plasma) than was that in whole blood (ρc, 0.62 for canine samples; ρc, 0.90 for feline samples). The mean difference between the glucose concentrations determined by the biochemical analyzer and the POCG in serum, plasma, and whole blood was 0.4, 0.3, and 31 mg/dL, respectively, for canine samples and 7, 6, and 32 mg/dL, respectively, for feline samples. Results indicated that use of a POCG to measure glucose concentrations in serum or plasma may increase the accuracy and reliability of diagnostic and treatment decisions associated with glucose homeostasis disorders in dogs and cats.

  8. Evaluation of the agreement among three handheld blood glucose meters and a laboratory blood analyzer for measurement of blood glucose concentration in Hispaniolan Amazon parrots (Amazona ventralis).

    Science.gov (United States)

    Acierno, Mark J; Mitchell, Mark A; Schuster, Patricia J; Freeman, Diana; Sanchez-Migallon Guzman, David; Tully, Thomas N

    2009-02-01

    To determine the degree of agreement between 3 commercially available point-of-care blood glucose meters and a laboratory analyzer for measurement of blood glucose concentrations in Hispaniolan Amazon parrots (Amazona ventralis). 20 healthy adult Hispaniolan Amazon parrots. A 26-gauge needle and 3-mL syringe were used to obtain a blood sample (approx 0.5 mL) from a jugular vein of each parrot. Small volumes of blood (0.6 to 1.5 microL) were used to operate each of the blood glucose meters, and the remainder was placed into lithium heparin microtubes and centrifuged. Plasma was harvested and frozen at -30 degrees C. Within 5 days after collection, plasma samples were thawed and plasma glucose concentrations were measured by means of the laboratory analyzer. Agreement between pairs of blood glucose meters and between each blood glucose meter and the laboratory analyzer was evaluated by means of the Bland-Altman method, and limits of agreement (LOA) were calculated. None of the results of the 3 blood glucose meters agreed with results of the laboratory analyzer. Each point-of-care blood glucose meter underestimated the blood glucose concentration, and the degree of negative bias was not consistent (meter A bias, -94.9 mg/dL [LOA, -148.0 to -41.7 mg/dL]; meter B bias, -52 mg/dL [LOA, -107.5 to 3.5 mg/dL]; and meter C bias, -78.9 mg/dL [LOA, -137.2 to -20.6 mg/dL]). On the basis of these results, use of handheld blood glucose meters in the diagnosis or treatment of Hispaniolan Amazon parrots and other psittacines cannot be recommended.

  9. Glucose and glycerol concentrations and their tracer enrichment measurements using liquid chromatography tandem mass spectrometry

    DEFF Research Database (Denmark)

    Bornø, Andreas; Foged, Lene; van Hall, Gerrit

    2014-01-01

    The present study describes a new liquid chromatography tandem mass spectrometry method for high-throughput quantification of glucose and glycerol in human plasma using stable isotopically labeled internal standards and is suitable for simultaneous measurements of glucose and glycerol enrichments...... of variation were 2.0% and 9.7%, respectively. After derivatization, plasma samples were stable for at least 14 days. In conclusion, we have developed and validated a novel, accurate, and sensitive high-throughput liquid chromatography tandem mass spectrometry method for simultaneous determination of glucose...

  10. Measuring Blood Glucose Concentrations in Photometric Glucometers Requiring Very Small Sample Volumes.

    Science.gov (United States)

    Demitri, Nevine; Zoubir, Abdelhak M

    2017-01-01

    Glucometers present an important self-monitoring tool for diabetes patients and, therefore, must exhibit high accuracy as well as good usability features. Based on an invasive photometric measurement principle that drastically reduces the volume of the blood sample needed from the patient, we present a framework that is capable of dealing with small blood samples, while maintaining the required accuracy. The framework consists of two major parts: 1) image segmentation; and 2) convergence detection. Step 1 is based on iterative mode-seeking methods to estimate the intensity value of the region of interest. We present several variations of these methods and give theoretical proofs of their convergence. Our approach is able to deal with changes in the number and position of clusters without any prior knowledge. Furthermore, we propose a method based on sparse approximation to decrease the computational load, while maintaining accuracy. Step 2 is achieved by employing temporal tracking and prediction, herewith decreasing the measurement time, and, thus, improving usability. Our framework is tested on several real datasets with different characteristics. We show that we are able to estimate the underlying glucose concentration from much smaller blood samples than is currently state of the art with sufficient accuracy according to the most recent ISO standards and reduce measurement time significantly compared to state-of-the-art methods.

  11. Determination of Glucose Concentration in Yeast Culture Medium

    Science.gov (United States)

    Hara, Seiichi; Kishimoto, Tomokazu; Muraji, Masafumi; Tsujimoto, Hiroaki; Azuma, Masayuki; Ooshima, Hiroshi

    The present paper describes a sensor for measuring the glucose concentration of yeast culture medium. The sensor determines glucose concentration by measuring the yield of hydrogen peroxide produced by glucose oxidase, which is monitored as luminescence using photomultiplier. The present sensor is able to measure low glucose concentration in media in which yeast cells keep respiration state. We herein describe the system and the characteristics of the glucose sensor.

  12. Comparison of a Point-of-Care Glucometer and a Laboratory Autoanalyzer for Measurement of Blood Glucose Concentrations in Domestic Pigeons ( Columba livia domestica).

    Science.gov (United States)

    Mohsenzadeh, Mahdieh Sadat; Zaeemi, Mahdieh; Razmyar, Jamshid; Azizzadeh, Mohammad

    2015-09-01

    Biochemical analysis is necessary for diagnosis and monitoring of diseases in birds; however, the small volume of blood that can be safely obtained from small avian species often limits laboratory diagnostic testing. Consequently, a suitable methodology requiring only a small volume of blood must be used. This study was designed to compare blood glucose concentrations in domestic pigeons ( Columba livia domestica) as measured by a commercial, handheld, human glucometer and a standard autoanalyzer. During the first phase of the study, whole blood samples obtained from 30 domestic pigeons were used to measure the blood glucose concentration with a glucometer, the packed cell volume (PCV), and the total erythrocyte count (nRBC). Plasma separated from the each sample was then used to obtain the plasma glucose concentration with the autoanalyzer. During the second phase of the study, 30 pigeons were assigned to 2 equal groups (n = 15). Hypoglycemia or hyperglycemia was induced in each group by intravenous injection of insulin or glucose, respectively. Blood was collected and processed, and glucose concentrations, PCV, and nRBC were measured as previously described. Linear-regression models demonstrated a significant relationship between results measured by the glucometer and autoanalyzer results from normoglycemic (correlation coefficient [R] = 0.43, P = .02), hypoglycemic (R = 0.95; P < .001), and hyperglycemic (R = 0.81; P < .001) birds. The results of this study suggest that we can predict the real blood-glucose concentration of pigeons by using results obtained by a glucometer.

  13. Evaluation of an Electrochemical Point-of-Care Meter for Measuring Glucose Concentration in Blood from Periparturient Dairy Cattle.

    Science.gov (United States)

    Megahed, A A; Hiew, M W H; Townsend, J R; Messick, J B; Constable, P D

    2015-01-01

    The Precision Xtra(®) meter is a promising low cost electrochemical point-of-care unit for measuring blood glucose concentration ([gluc]) in cattle blood. The meter uses an algorithm that assumes the intra-erythrocyte [gluc] equals the plasma [gluc] on a molal basis, and that the hematocrit is similar in humans and cattle. The primary objective was to determine the accuracy of the meter for measuring plasma [gluc] in dairy cattle. Secondary objectives were to characterize the influence of hematocrit and sample temperature on the measured value for [gluc]. A total of 106 periparturient Holstein-Friesian cattle. Blood and plasma samples (1,109) were obtained and Deming regression and Bland-Altman plots were used to determine the accuracy of the meter against the reference method (plasma hexokinase assay). Multivariable regression and linear regression were used to determine the effect of hematocrit and sample temperature on the plasma [gluc] measured by the meter. Intra-erythrocyte [gluc] was 18% of plasma [gluc] on a molar basis. Sample temperature had a significant linear effect on plasma [gluc] as measured by the meter for 3/5 plasma samples when measured [gluc] > 160 mg/dL. The meter utilizes an algorithm that is optimized for human blood and is inaccurate when applied to bovine blood. Until a cattle-specific algorithm is developed, we recommend using plasma as the analyte instead of blood and calculating plasma [gluc] using the equation: [gluc] = 0.66 × [gluc]p-meter + 15, where [gluc]p-meter is the value reported by the meter. If blood is measured, then we recommend using the equation: [gluc] = 0.90 × [gluc]b-meter + 15. Copyright © 2015 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  14. No relationship between cerebral blood flow velocity and cerebrovascular reserve capacity and contemporaneously measured glucose and insulin concentrations in diabetes mellitus

    NARCIS (Netherlands)

    Fülesdi, B.; Limburg, M.; Bereczki, D.; Molnár, C.; Michels, R. P.; Leányvári, Z.; Csiba, L.

    1999-01-01

    Blood glucose and insulin concentrations have been reported to influence cerebral hemodynamics. We studied the relationship between actual blood glucose and insulin concentrations and resting cerebral blood flow velocity in the middle cerebral artery and cerebrovascular reserve capacity after

  15. TheClinical Research Tool: a high-performance microdialysis-based system for reliably measuring interstitial fluid glucose concentration.

    Science.gov (United States)

    Ocvirk, Gregor; Hajnsek, Martin; Gillen, Ralph; Guenther, Arnfried; Hochmuth, Gernot; Kamecke, Ulrike; Koelker, Karl-Heinz; Kraemer, Peter; Obermaier, Karin; Reinheimer, Cornelia; Jendrike, Nina; Freckmann, Guido

    2009-05-01

    A novel microdialysis-based continuous glucose monitoring system, the so-called Clinical Research Tool (CRT), is presented. The CRT was designed exclusively for investigational use to offer high analytical accuracy and reliability. The CRT was built to avoid signal artifacts due to catheter clogging, flow obstruction by air bubbles, and flow variation caused by inconstant pumping. For differentiation between physiological events and system artifacts, the sensor current, counter electrode and polarization voltage, battery voltage, sensor temperature, and flow rate are recorded at a rate of 1 Hz. In vitro characterization with buffered glucose solutions (c(glucose) = 0 - 26 x 10(-3) mol liter(-1)) over 120 h yielded a mean absolute relative error (MARE) of 2.9 +/- 0.9% and a recorded mean flow rate of 330 +/- 48 nl/min with periodic flow rate variation amounting to 24 +/- 7%. The first 120 h in vivo testing was conducted with five type 1 diabetes subjects wearing two systems each. A mean flow rate of 350 +/- 59 nl/min and a periodic variation of 22 +/- 6% were recorded. Utilizing 3 blood glucose measurements per day and a physical lag time of 1980 s, retrospective calibration of the 10 in vivo experiments yielded a MARE value of 12.4 +/- 5.7. Clarke error grid analysis resulted in 81.0%, 16.6%, 0.8%, 1.6%, and 0% in regions A, B, C, D, and E, respectively. The CRT demonstrates exceptional reliability of system operation and very good measurement performance. The ability to differentiate between artifacts and physiological effects suggests the use of the CRT as a reference tool in clinical investigations. 2009 Diabetes Technology Society.

  16. Prediction Methods for Blood Glucose Concentration

    DEFF Research Database (Denmark)

    “Recent Results on Glucose–Insulin Predictions by Means of a State Observer for Time-Delay Systems” by Pasquale Palumbo et al. introduces a prediction model which in real time predicts the insulin concentration in blood which in turn is used in a control system. The method is tested in simulation...... EEG signals to predict upcoming hypoglycemic situations in real-time by employing artificial neural networks. The results of a 30-day long clinical study with the implanted device and the developed algorithm are presented. The chapter “Meta-Learning Based Blood Glucose Predictor for Diabetic......, but the insulin amount is chosen using factors that account for this expectation. The increasing availability of more accurate continuous blood glucose measurement (CGM) systems is attracting much interest to the possibilities of explicit prediction of future BG values. Against this background, in 2014 a two...

  17. Measuring brain glucose phosphorylation with labeled glucose

    International Nuclear Information System (INIS)

    Brondsted, H.E.; Gjedde, A.

    1988-01-01

    This study tested whether glucose labeled at the C-6 position generates metabolites that leave brain so rapidly that C-6-labeled glucose cannot be used to measure brain glucose phosphorylation (CMRGlc). In pentobarbital-anesthetized rats, the parietal cortex uptake of [ 14 C]glucose labeled in the C-6 position was followed for times ranging from 10 s to 60 min. We subtracted the observed radioactivity from the radioactivity expected with no loss of labeled metabolites from brain by extrapolation of glucose uptake in an initial period when loss was negligible. The observed radioactivity was a monoexponentially declining function of the total radioactivity expected in the absence of metabolite loss. The constant of decline was 0.0077.min-1 for parietal cortex. Metabolites were lost from the beginning of the experiment. However, with correction for the loss of labeled metabolites, it was possible to determine an average CMRGlc between 4 and 60 min of circulation of 64 +/- 4 (SE; n = 49) mumol.hg-1.min-1

  18. Cutpoints for screening blood glucose concentrations in healthy senior cats.

    Science.gov (United States)

    Reeve-Johnson, Mia K; Rand, Jacquie S; Vankan, Dianne; Anderson, Stephen T; Marshall, Rhett; Morton, John M

    2017-12-01

    Objectives The objectives of this study were to determine the reference interval for screening blood glucose in senior cats, to apply this to a population of obese senior cats, to compare screening and fasting blood glucose, to assess whether screening blood glucose is predicted by breed, body weight, body condition score (BCS), behaviour score, fasting blood glucose and/or recent carbohydrate intake and to assess its robustness to changes in methodology. Methods The study included a total of 120 clinically healthy client-owned cats aged 8 years and older of varying breeds and BCSs. Blood glucose was measured at the beginning of the consultation from an ear/paw sample using a portable glucose meter calibrated for cats, and again after physical examination from a jugular sample. Fasting blood glucose was measured after overnight hospitalisation and fasting for 18-24 h. Results The reference interval upper limit for screening blood glucose was 189 mg/dl (10.5 mmol/l). Mean screening blood glucose was greater than mean fasting glucose. Breed, body weight, BCS, behaviour score, fasting blood glucose concentration and amount of carbohydrate consumed 2-24 h before sampling collectively explained only a small proportion of the variability in screening blood glucose. Conclusions and relevance Screening blood glucose measurement represents a simple test, and cats with values from 117-189 mg/dl (6.5-10.5 mmol/l) should be retested several hours later. Cats with initial screening blood glucose >189 mg/dl (10.5 mmol/l), or a second screening blood glucose >116 mg/dl (6.4 mmol/l) several hours after the first, should have fasting glucose and glucose tolerance measured after overnight hospitalisation.

  19. Thresholds of whole-blood β-hydroxybutyrate and glucose concentrations measured with an electronic hand-held device to identify ovine hyperketonemia.

    Science.gov (United States)

    Pichler, M; Damberger, A; Schwendenwein, I; Gasteiner, J; Drillich, M; Iwersen, M

    2014-03-01

    Metabolic disorders, especially hyperketonemia, are very common in dairy sheep. The whole-blood concentrations of β-hydroxybutyrate (BHBA) and glucose can be determined by commercially available electronic hand-held devices, which are used in human medicine and for the detection of ketosis in dairy cows. The aim of this study was to evaluate the suitability of the hand-held device Precision Xceed (PX; Abbott Diabetes Care Inc., Abbott Park, IL) to detect hyperketonemia in ewes. An additional objective of this study was to evaluate the agreement between samples obtained by minimal invasive venipuncture of an ear vein and measurements of whole-blood samples from the jugular vein (vena jugularis, v. jug.). Blood samples taken from the v. jug. were collected from 358 ewes on 4 different farms. These samples and a blood drop obtained from an ear vein were analyzed simultaneously on farm with the PX. For method comparison, the samples obtained from the v. jug. were also analyzed by standard methods, which served as the gold standard at the Central Laboratory of the University of Veterinary Medicine Vienna, Austria. The correlation coefficients between the serum BHBA concentration and the concentrations measured with the hand-held meter in the whole blood from an ear vein and the v. jug. were 0.94 and 0.96, respectively. The correlation coefficients of plasma and whole-blood glucose concentration were 0.68 for the v. jug. and 0.47 for the ear vein. The mean glucose concentration was significantly lower in animals classified as hyperketonemic (BHBA ≥ 1.6 mmol/L) compared with healthy ewes. Whole-blood concentrations of BHBA and glucose measured with the PX from v. jug. showed a constant negative bias of 0.15 mmol/L and 8.4 mg/dL, respectively. Hence, a receiver operating characteristic analysis was performed to determine thresholds for the PX to detect hyperketonemia in ewes. This resulted in thresholds for moderate ketosis of BHBA concentrations of 0.7 mmol/L in blood

  20. Genetic Algorithm Tuning of PID Controller in Smith Predictor for Glucose Concentration Control

    OpenAIRE

    Tsonyo Slavov; Olympia Roeva

    2011-01-01

    This paper focuses on design of a glucose concentration control system based on nonlinear model plant of E. coli MC4110 fed-batch cultivation process. Due to significant time delay in real time glucose concentration measurement, a correction is proposed in glucose concentration measurement and a Smith predictor (SP) control structure based on universal PID controller is designed. To reduce the influence of model error in SP structure the estimate of measured glucose concentration is used. For...

  1. Prediction Methods for Blood Glucose Concentration

    DEFF Research Database (Denmark)

    -day workshop on the design, use and evaluation of prediction methods for blood glucose concentration was held at the Johannes Kepler University Linz, Austria. One intention of the workshop was to bring together experts working in various fields on the same topic, in order to shed light from different angles...... discussions which allowed to receive direct feedback from the point of view of different disciplines. This book is based on the contributions of that workshop and is intended to convey an overview of the different aspects involved in the prediction. The individual chapters are based on the presentations given...... in the process of writing this book: All authors for their individual contributions, all reviewers of the book chapters, Daniela Hummer for the entire organization of the workshop, Boris Tasevski for helping with the typesetting, Florian Reiterer for his help editing the book, as well as Oliver Jackson and Karin...

  2. Salivary glucose concentration and excretion in normal and diabetic subjects.

    Science.gov (United States)

    Jurysta, Cedric; Bulur, Nurdan; Oguzhan, Berrin; Satman, Ilhan; Yilmaz, Temel M; Malaisse, Willy J; Sener, Abdullah

    2009-01-01

    The present report aims mainly at a reevaluation of salivary glucose concentration and excretion in unstimulated and mechanically stimulated saliva in both normal and diabetic subjects. In normal subjects, a decrease in saliva glucose concentration, an increase in salivary flow, but an unchanged glucose excretion rate were recorded when comparing stimulated saliva to unstimulated saliva. In diabetic patients, an increase in salivary flow with unchanged salivary glucose concentration and glucose excretion rate were observed under the same experimental conditions. Salivary glucose concentration and excretion were much higher in diabetic patients than in control subjects, whether in unstimulated or stimulated saliva. No significant correlation between glycemia and either glucose concentration or glucose excretion rate was found in the diabetic patients, whether in unstimulated or stimulated saliva. In the latter patients, as compared to control subjects, the relative magnitude of the increase in saliva glucose concentration was comparable, however, to that of blood glucose concentration. The relationship between these two variables was also documented in normal subjects and diabetic patients undergoing an oral glucose tolerance test.

  3. Data Based Prediction of Blood Glucose Concentrations Using Evolutionary Methods.

    Science.gov (United States)

    Hidalgo, J Ignacio; Colmenar, J Manuel; Kronberger, Gabriel; Winkler, Stephan M; Garnica, Oscar; Lanchares, Juan

    2017-08-08

    Predicting glucose values on the basis of insulin and food intakes is a difficult task that people with diabetes need to do daily. This is necessary as it is important to maintain glucose levels at appropriate values to avoid not only short-term, but also long-term complications of the illness. Artificial intelligence in general and machine learning techniques in particular have already lead to promising results in modeling and predicting glucose concentrations. In this work, several machine learning techniques are used for the modeling and prediction of glucose concentrations using as inputs the values measured by a continuous monitoring glucose system as well as also previous and estimated future carbohydrate intakes and insulin injections. In particular, we use the following four techniques: genetic programming, random forests, k-nearest neighbors, and grammatical evolution. We propose two new enhanced modeling algorithms for glucose prediction, namely (i) a variant of grammatical evolution which uses an optimized grammar, and (ii) a variant of tree-based genetic programming which uses a three-compartment model for carbohydrate and insulin dynamics. The predictors were trained and tested using data of ten patients from a public hospital in Spain. We analyze our experimental results using the Clarke error grid metric and see that 90% of the forecasts are correct (i.e., Clarke error categories A and B), but still even the best methods produce 5 to 10% of serious errors (category D) and approximately 0.5% of very serious errors (category E). We also propose an enhanced genetic programming algorithm that incorporates a three-compartment model into symbolic regression models to create smoothed time series of the original carbohydrate and insulin time series.

  4. Extended Near-Infrared Optoacoustic Spectrometry for Sensing Physiological Concentrations of Glucose

    Directory of Open Access Journals (Sweden)

    Ara Ghazaryan

    2018-03-01

    Full Text Available Glucose sensing is pursued extensively in biomedical research and clinical practice for assessment of the carbohydrate and fat metabolism as well as in the context of an array of disorders, including diabetes, morbid obesity, and cancer. Currently used methods for real-time glucose measurements are invasive and require access to body fluids, with novel tools and methods for non-invasive sensing of the glucose levels highly desired. In this study, we introduce a near-infrared (NIR optoacoustic spectrometer for sensing physiological concentrations of glucose within aqueous media and describe the glucose spectra within 850–1,900 nm and various concentration ranges. We apply the ratiometric and dictionary learning methods with a training set of data and validate their utility for glucose concentration measurements with optoacoustics in the probe dataset. We demonstrate the superior signal-to-noise ratio (factor of ~3.9 achieved with dictionary learning over the ratiometric approach across the wide glucose concentration range. Our data show a linear relationship between the optoacoustic signal intensity and physiological glucose concentration, in line with the results of optical spectroscopy. Thus, the feasibility of detecting physiological glucose concentrations using NIR optoacoustic spectroscopy is demonstrated, enabling the sensing glucose with ±10 mg/dl precision.

  5. Polymer Optical Fiber Compound Parabolic Concentrator fiber tip based glucose sensor: In-Vitro Testing

    DEFF Research Database (Denmark)

    Hassan, Hafeez Ul; Janting, Jakob; Aasmul, Soren

    2016-01-01

    We present in-vitro sensing of glucose using a newly developed efficient optical fiber glucose sensor based on a Compound Parabolic Concentrator (CPC) tipped polymer optical fiber (POF). A batch of 9 CPC tipped POF sensors with a 35 mm fiber length is shown to have an enhanced fluorescence pickup...... efficiency with an average increment factor of 1.7 as compared to standard POF sensors with a plane cut fiber tip. Invitro measurements for two glucose concentrations (40 and 400 mg/dL) confirm that the CPC tipped sensors efficiently can detect both glucose concentrations. it sets the footnote at the bottom...

  6. Effects of taurine on plasma glucose concentration and active glucose transport in the small intestine.

    Science.gov (United States)

    Tsuchiya, Yo; Kawamata, Koichi

    2017-11-01

    Taurine lowers blood glucose levels and improves hyperglycemia. However, its effects on glucose transport in the small intestine have not been investigated. Here, we elucidated the effect of taurine on glucose absorption in the small intestine. In the oral glucose tolerance test, addition of 10 mmol/L taurine suppressed the increase in hepatic portal glucose concentrations. To investigate whether the suppressive effect of taurine occurs via down-regulation of active glucose transport in the small intestine, we performed an assay using the everted sac of the rat jejunum. Addition of taurine to the mucosal side of the jejunum suppressed active glucose transport via sodium-glucose cotransporter 1 (SGLT1). After elimination of chloride ions from the mucosal solution, taurine did not show suppressive effects on active glucose transport. These results suggest that taurine suppressed the increase in hepatic portal glucose concentrations via suppression of SGLT1 activity in the rat jejunum, depending on chloride ions. © 2017 Japanese Society of Animal Science.

  7. FK concentrator outdoor measurements

    OpenAIRE

    Hernández Sanz, Maikel; Vilaplana, J., J.; Benitez Gimenez, Pablo; Mohedano,, Rubén; Zamora Herranz, Pablo; Miñano Dominguez, Juan Carlos; Mendes Lopes, Joao

    2013-01-01

    The FK is a two-stage optical concentrator for CPV, composed by a Fresnel lens working as POE and a refractive element working as SOE. Both elements perform Köhler integration, for uniform irradiance purposes. The FK has demonstrated that compares very well with other Fresnel-based concentrator optics. Recent on-sun measurements carried out on an FK mono-module prototype have already shown outstanding results, achieving electrical efficiencies over 34%. Further optimization of optical design ...

  8. Conjoint regulation of glucagon concentrations via plasma insulin and glucose in dairy cows.

    Science.gov (United States)

    Zarrin, M; Wellnitz, O; Bruckmaier, R M

    2015-04-01

    Insulin and glucagon are glucoregulatory hormones that contribute to glucose homeostasis. Plasma insulin is elevated during normoglycemia or hyperglycemia and acts as a suppressor of glucagon secretion. We have investigated if and how insulin and glucose contribute to the regulation of glucagon secretion through long term (48 h) elevated insulin concentrations during simultaneous hypoglycemia or euglycemia in mid-lactating dairy cows. Nineteen Holstein dairy cows were randomly assigned to 3 treatment groups: an intravenous insulin infusion (HypoG, n = 5) to decrease plasma glucose concentrations (2.5 mmol/L), a hyperinsulinemic-euglycemic clamp to study effects of insulin at simultaneously normal glucose concentrations (EuG, n = 6) and a 0.9% saline infusion (NaCl, n = 8). Plasma glucose was measured at 5-min intervals, and insulin and glucose infusion rates were adjusted accordingly. Area under the curve of hourly glucose, insulin, and glucagon concentrations on day 2 of infusion was evaluated by analysis of variance with treatments as fixed effect. Insulin infusion caused an increase of plasma insulin area under the curve (AUC)/h in HypoG (41.9 ± 8.1 mU/L) and EuG (57.8 ± 7.8 mU/L) compared with NaCl (13.9 ± 1.1 mU/L; P insulin infusion induces elevated glucagon concentrations during hypoglycemia, although the same insulin infusion reduces glucagon concentrations at simultaneously normal glucose concentrations. Thus, insulin does not generally have an inhibitory effect on glucagon concentrations. If simultaneously glucose is low and insulin is high, glucagon is upregulated to increase glucose availability. Therefore, insulin and glucose are conjoint regulatory factors of glucagon concentrations in dairy cows, and the plasma glucose status is the key factor to decide if its concentrations are increased or decreased. This regulatory effect can be important for the maintenance of glucose homeostasis if insulin secretion is upregulated by other factors than high

  9. Fasting blood glucose and haemoglobin concentrations of healthy ...

    African Journals Online (AJOL)

    Menstruation is associated with loss of blood monthly in women of reproductive age. In some women this physiological phenomenon is also associated with some complaints such as menstrual pain, vomiting, and tiredness. We investigated the fasting blood glucose concentration and hemoglobin concentration before and ...

  10. Effect of varying concentrations of orally ingested glucose on platelet ...

    African Journals Online (AJOL)

    The physiologic basis of bleeding is a function of normal platelets and coagulation factors. This study is aimed at ascertaining the effect of varying concentrations of orally ingested glucose on platelet count and hemoglobin concentration during menstruation. Forty menstruating students between the ages of 18 and 25 from ...

  11. Salivary glucose concentration exhibits threshold kinetics in normal-weight, overweight, and obese children

    Directory of Open Access Journals (Sweden)

    Hartman ML

    2014-12-01

    Full Text Available Mor-Li Hartman,1 J Max Goodson,1 Roula Barake,2 Osama Alsmadi,3 Sabiha Al-Mutawa,4 Jitendra Ariga,4 Pramod Soparkar,1 Jawad Behbehani,5 Kazem Behbehani,6 Francine Welty7 1Department of Applied Oral Sciences, The Forsyth Institute, Cambridge, MA, USA; 2Department of Nutrition, The Dasman Diabetes Institute, Dasman, Kuwait; 3Genome Center, The Dasman Diabetes Institute, Dasman, Kuwait; 4Ministry of Health, Kuwait City, Kuwait; 5Faculty of Dentistry, Kuwait University, Kuwait City, Kuwait; 6The Dasman Diabetes Institute, Dasman, Kuwait; 7Division of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, USA Background: Metabolic syndrome in childhood predicts the development of cardiovascular disease and type 2 diabetes (T2D in adulthood. Testing for features of metabolic syndrome, such as fasting plasma glucose concentration, requires blood sampling which can be difficult in children. Here we evaluated salivary glucose concentration as a surrogate measurement for plasma glucose concentration in 11-year-old US children. Methods: Children from Portland, Maine, and Cambridge, Massachusetts, with a mean age of 10.6±0.2 years provided 6-hour fasting samples of both blood and whole saliva. Salivary glucose levels were measured with a high-sensitivity assay (sensitivity =0.002 mg/dL. Plasma glucose levels were determined by a commercial clinical laboratory. Blood pressure, salivary flow rate, height, and weight were also measured. Results: Of the 65 children enrolled, there were two underweight children (3.1%, 30 normal-weight children (46.2%, 12 overweight children (18.4%, and 21 obese children (32.3%. The mean overall glucose concentrations were 0.11±0.02 mg/dL in saliva and 86.3±0.8 mg/dL in plasma, and these did not differ significantly by body–weight groups. By regression analysis, the plasma concentration equaled 13.5 times the saliva concentration, with a threshold level of 84.8 mg/dL. Salivary glucose values less than threshold plasma

  12. A review of metabolism of labeled glucoses for use in measuring glucose recycling

    International Nuclear Information System (INIS)

    Russell, R.W.; Young, J.W.

    1990-01-01

    The fate of tritium from each carbon of D-glucose and the metabolism of L-glucose and 2-deoxy-D-glucose are known. Differences in metabolism of labeled glucoses can be used to quantify physical and chemical recycling of glucose. Only physical recycling is measured by [1- 3 H]-L-glucose, whereas [U- 14 C]-D-glucose measures total recycling. The difference between [1- 3 H]-L-glucose and [U- 14 C]-D-glucose, therefore, is chemical recycling. Recycling from extracellular binding sites and hepatic glucose 6-phosphate can be measured by difference between [1,2- 3 H]-2-deoxy-D-glucose and [1- 3 H]-L-glucose, and the difference in irreversible loss of the two will measure extrahepatic uptake of D-glucose. Recycling via Cori-alanine cycle plus CO 2 is the difference in irreversible loss measured by using [6- 3 H]-glucose and [U- 14 C]-D-glucose. Recycling via the hexose monophosphate pathway can be determined by difference in irreversible loss between [1- 3 H]-D-glucose and [6- 3 H]-D-glucose. Recycling via CO 2 and glycerol must be measured directly with [U- 14 C]glucose, bicarbonate, and glycerol. Recycling via hepatic glycogen can be estimated by subtracting all other measured chemical recycling from total chemical recycling. This review describes means to quantify glucose recycling in vivo, enabling studies of mechanisms for conservation and utilization of glucose. 54 references

  13. Effect of chronic hypoglycaemia on glucose concentration and glycogen content in rat brain: a localized 13C NMR study

    OpenAIRE

    Lei, Hongxia; Gruetter, Rolf

    2006-01-01

    While chronic hypoglycaemia has been reported to increase unidirectional glucose transport across the blood-brain barrier (BBB) and to increase GLUT1 expression at the endothelium, the effect on steady-state brain d-glucose and brain glycogen content is currently unknown. Brain glucose and glycogen concentrations were directly measured in vivo using localized 13C magnetic resonance spectroscopy (MRS) following 12-14 days of hypoglycaemia. Brain glucose content was significantly increased by 4...

  14. Exogenous glucagon-like peptide-1 attenuates glucose absorption and reduces blood glucose concentration after small intestinal glucose delivery in critical illness.

    Science.gov (United States)

    Miller, Asaf; Deane, Adam M; Plummer, Mark P; Cousins, Caroline E; Chapple, Lee-Anne S; Horowitz, Michael; Chapman, Marianne J

    2017-03-01

    To evaluate the effect of exogenous glucagonlike peptide-1 (GLP-1) on small intestinal glucose absorption and blood glucose concentrations during critical illness. A prospective, blinded, placebo-controlled, cross-over, randomised trial in a mixed medical-surgical adult intensive care unit, with 12 mechanically ventilated critically ill patients, who were suitable for receiving small intestinal nutrient. On consecutive days, in a randomised order, participants received intravenous GLP-1 (1.2 pmol/ kg/min) or placebo (0.9% saline) as a continuous infusion over 270 minutes. After 6 hours of fasting, intravenous infusions of GLP-1 or placebo began at T = -30 min (in which T = time), with the infusion maintained at a constant rate until study completion at T = 240 min. At T = 0 min, a 100 mL bolus of mixed liquid nutrient meal (1 kcal/mL) containing 3 g of 3-O-methyl-D-gluco-pyranose (3-OMG), a marker of glucose absorption, was administered directly into the small intestine, via a post-pyloric catheter, over 6 minutes. Blood samples were taken at regular intervals for the measurement of plasma glucose and 3-OMG concentrations. Intravenous GLP-1 attenuated initial small intestinal glucose absorption (mean area under the curve [AUC] 0-30 for 3-OMG: GLP-1 group, 4.4 mmol/L/min [SEM, 0.9 mmol/L/min] v placebo group, 6.5 mmol/L/min [SEM, 1.0 mmol/L/min]; P = 0.01), overall small intestinal glucose absorption (mean AUC 0-240 for 3-OMG: GLP-1, 68.2 mmol/L/ min [SEM, 4.7 mmol/L/min] v placebo, 77.7 mmol/L/min [SEM, 4.4 mmol/lLmin]; P = 0.02), small intestinal glucose absorption and overall blood glucose concentration (mean AUC 0-240 for blood glucose: GLP-1, 2062 mmol/L/min [SEM, 111 mmol/L/min] v placebo 2328 mmol/L/min [SEM, 145 mmol/L/min]; P = 0.005). Short-term administration of exogenous GLP-1 reduces small intestinal glucose absorption for up to 4 hours during critical illness. This is likely to be an additional mechanism for the glucose-lowering effect of this agent.

  15. In vivo measurements of brain glucose transport using the reversible michaelis-menten model and simultaneous measurements of cerebral blood flow changes during hypoglycemia

    OpenAIRE

    Choi, I.-Y.; Lee, S.-P.; Kim, S.-G.; Gruetter, R.

    2001-01-01

    Glucose is the major substrate that sustains normal brain function. When the brain glucose concentration approaches zero, glucose transport across the blood-brain barrier becomes rate limiting for metabolism during, for example, increased metabolic activity and hypoglycemia. Steady-state brain glucose concentrations in α-chloralose anesthetized rats were measured noninvasively as a function of plasma glucose. The relation between brain and plasma glucose was linear at 4.5 to 30 mmol/L plasma ...

  16. Photoacoustic determination of glucose concentration in whole blood by a near-infrared laser diode

    Science.gov (United States)

    Zhao, Zuomin; Myllylae, Risto A.

    2001-06-01

    The near-infrared photoacoustic technique is recognized as a potential method for the non-invasive determination of human glucose, because near-infrared light can incident a few millimeters into human tissue, where it produces an acoustic wave capable of carrying information about the composition of the tissue. This paper demonstrates a photoacoustic glucose measurement in a blood sample as a step toward a non-invasive measurement. The experimental apparatus consists of a near-infrared laser diode operating with 4 micro joules pulse energy at 905 nm, a roller pump connected to a silicon plastic tube and a cuvette for circulating the blood sample. In addition, the apparatus comprises a PZT piezoelectric transducer integrated with a battery-powered preamplifier to receive the photoacoustic signal. During the experiment, a glucose solution is mixed into a human blood sample to change its concentration. Although the absorption coefficient of glucose is much smaller than that of blood in the near-infrared region, the osmotic and hydrophilic properties of glucose decrease the reduced scattering coefficient of blood caused by the dissolved glucose surrounding the blood cells. This changes the distribution of the absorbed optical energy in blood, which, in turn, produces a change in the photoacoustic signal. Our experiment demonstrates that signal amplitudes in fresh and stored blood samples in crease about 7% and 10%, respectively, when the glucose concentration reaches the upper limit of the physiological region (500 mg/dl).

  17. Effect of ground cinnamon on postprandial blood glucose concentration in normal-weight and obese adults.

    Science.gov (United States)

    Magistrelli, Ashley; Chezem, Jo Carol

    2012-11-01

    In healthy normal-weight adults, cinnamon reduces blood glucose concentration and enhances insulin sensitivity. Insulin resistance, resulting in increased fasting and postprandial blood glucose and insulin levels, is commonly observed in obese individuals. The objective of the study was to compare declines in postprandial glycemic response in normal-weight and obese subjects with ingestion of 6 g ground cinnamon. In a crossover study, subjects consumed 50 g available carbohydrate in instant farina cereal, served plain or with 6 g ground cinnamon. Blood glucose concentration, the main outcome measure, was assessed at minutes 0, 15, 30, 45, 60, 90, and 120. Repeated-measures analysis of variance evaluated the effects of body mass index (BMI) group, dietary condition, and time on blood glucose. Paired t-test assessed blood glucose at individual time points and glucose area under the curve (AUC) between dietary conditions. Thirty subjects between the ages of 18 and 30 years, 15 with BMIs between 18.5 and 24.9 and 15 with BMIs of 30.0 or more, completed the study. There was no significant difference in blood glucose between the two BMI groups at any time point. However, in a combined analysis of all subjects, the addition of cinnamon to the cereal significantly reduced 120-minute glucose AUC (P=0.008) and blood glucose at 15 (P=0.001), 30 (Pblood glucose was significantly higher with cinnamon consumption (Pglucose response in normal weight and obese adults. Copyright © 2012 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  18. Lowering Plasma Glucose Concentration by Inhibiting Renal Sodium-Glucose Co-Transport

    Science.gov (United States)

    Abdul-Ghani, Muhammad A; DeFronzo, Ralph A

    2017-01-01

    Maintaining normoglycaemia not only reduces the risk of diabetic microvascular complications but also corrects the metabolic abnormalities that contribute to the development and progression of hyperglycaemia (i.e. insulin resistance and beta-cell dysfunction). Progressive beta-cell failure, in addition to the multiple side effects associated with many current antihyperglycaemic agents (e.g., hypoglycaemia and weight gain) presents major obstacle to the achievement of the recommended goal of glycaemic control in patients with diabetes mellitus (DM). Thus, novel effective therapies are needed for optimal glucose control in subjects with DM. Recently, specific inhibitors of renal sodium glucose cotransporter 2 (SGLT2) have been developed to produce glucosuria and lower the plasma glucose concentration. Because of their unique mechanism of action (which is independent of the secretion and action of insulin), these agents are effective in lowering the plasma glucose concentration in all stages of DM and can be combined with all other antidiabetic agents. In this review, we summarize the available data concerning the mechanism of action, efficacy and safety of this novel class of antidiabetic agent. PMID:24690096

  19. Sleep/wake dependent changes in cortical glucose concentrations.

    Science.gov (United States)

    Dash, Michael B; Bellesi, Michele; Tononi, Giulio; Cirelli, Chiara

    2013-01-01

    Most of the energy in the brain comes from glucose and supports glutamatergic activity. The firing rate of cortical glutamatergic neurons, as well as cortical extracellular glutamate levels, increase with time spent awake and decline throughout non rapid eye movement sleep, raising the question whether glucose levels reflect behavioral state and sleep/wake history. Here chronic (2-3 days) electroencephalographic recordings in the rat cerebral cortex were coupled with fixed-potential amperometry to monitor the extracellular concentration of glucose ([gluc]) on a second-by-second basis across the spontaneous sleep-wake cycle and in response to 3 h of sleep deprivation. [Gluc] progressively increased during non rapid eye movement sleep and declined during rapid eye movement sleep, while during wake an early decline in [gluc] was followed by an increase 8-15 min after awakening. There was a significant time of day effect during the dark phase, when rats are mostly awake, with [gluc] being significantly lower during the last 3-4 h of the night relative to the first 3-4 h. Moreover, the duration of the early phase of [gluc] decline during wake was longer after prolonged wake than after consolidated sleep. Thus, the sleep/wake history may affect the levels of glucose available to the brain upon awakening. © 2012 The Authors Journal of Neurochemistry © 2012 International Society for Neurochemistry.

  20. The rate of intestinal glucose absorption is correlated with plasma glucose-dependent insulinotropic polypeptide concentrations in healthy men

    DEFF Research Database (Denmark)

    Wachters-Hagedoorn, Renate E; Priebe, Marion G; Heimweg, Janneke A J

    2006-01-01

    and slowly available glucose. In a crossover study, glucose, insulin, GLP-1, and GIP concentrations were monitored for 6 h after consumption of glucose, uncooked cornstarch (UCCS) or corn pasta in 7 healthy men. All test meals were naturally labeled with 13C. Using a primed, continuous D-[6,6-2H2]glucose...... in the early postprandial phase (15-90 min) occurred after consumption of glucose. There was a strong positive within-subject correlation between RaEx and GIP concentrations (r = 0.73, P meals. Rapidly and slowly digestible carbohydrates differ considerably in their ability to stimulate...

  1. Detection of saliva-range glucose concentrations using organic thin-film transistors

    International Nuclear Information System (INIS)

    Elkington, D.; Belcher, W. J.; Dastoor, P. C.; Zhou, X. J.

    2014-01-01

    We describe the development of a glucose sensor through direct incorporation of an enzyme (glucose oxidase) into the gate of an organic thin film transistor (OTFT). We show that glucose diffusion is the key determinant of the device response time and present a mechanism of glucose sensing in these devices that involves protonic doping of the transistor channel via enzymatic oxidation of glucose. The integrated OTFT sensor is sensitive across 4 decades of glucose concentration; a range that encompasses both the blood and salivary glucose concentration levels. As such, this work acts as a proof-of-concept for low-cost printed biosensors for salivary glucose.

  2. Detection of saliva-range glucose concentrations using organic thin-film transistors

    Energy Technology Data Exchange (ETDEWEB)

    Elkington, D.; Belcher, W. J.; Dastoor, P. C.; Zhou, X. J. [Centre for Organic Electronics, University of Newcastle, Callaghan, New South Wales 2308 (Australia)

    2014-07-28

    We describe the development of a glucose sensor through direct incorporation of an enzyme (glucose oxidase) into the gate of an organic thin film transistor (OTFT). We show that glucose diffusion is the key determinant of the device response time and present a mechanism of glucose sensing in these devices that involves protonic doping of the transistor channel via enzymatic oxidation of glucose. The integrated OTFT sensor is sensitive across 4 decades of glucose concentration; a range that encompasses both the blood and salivary glucose concentration levels. As such, this work acts as a proof-of-concept for low-cost printed biosensors for salivary glucose.

  3. Genetic Algorithm Tuning of PID Controller in Smith Predictor for Glucose Concentration Control

    Directory of Open Access Journals (Sweden)

    Tsonyo Slavov

    2011-07-01

    Full Text Available This paper focuses on design of a glucose concentration control system based on nonlinear model plant of E. coli MC4110 fed-batch cultivation process. Due to significant time delay in real time glucose concentration measurement, a correction is proposed in glucose concentration measurement and a Smith predictor (SP control structure based on universal PID controller is designed. To reduce the influence of model error in SP structure the estimate of measured glucose concentration is used. For the aim an extended Kalman filter (EKF is designed. To achieve good closed-loop system performance genetic algorithm (GA based optimal controller tuning procedure is applied. A standard binary encoding GA is applied. The GA parameters and operators are specified for the considered here problem. As a result the optimal PID controller settings are obtained. The simulation experiments of the control systems based on SP with EKF and without EKF are performed. The results show that the control system based on SP with EKF has a better performance than the one without EKF. For a short time the controller sets the control variable and maintains it at the desired set point during the cultivation process. As a result, a high biomass concentration of 48.3 g·l-1 is obtained at the end of the process.

  4. The salivary microbiome is altered in the presence of a high salivary glucose concentration.

    Directory of Open Access Journals (Sweden)

    J Max Goodson

    Full Text Available Type II diabetes (T2D has been associated with changes in oral bacterial diversity and frequency. It is not known whether these changes are part of the etiology of T2D, or one of its effects.We measured the glucose concentration, bacterial counts, and relative frequencies of 42 bacterial species in whole saliva samples from 8,173 Kuwaiti adolescents (mean age 10.00 ± 0.67 years using DNA probe analysis. In addition, clinical data related to obesity, dental caries, and gingivitis were collected. Data were compared between adolescents with high salivary glucose (HSG; glucose concentration ≥ 1.0 mg/d, n = 175 and those with low salivary glucose (LSG, glucose concentration < 0.1 mg/dL n = 2,537.HSG was associated with dental caries and gingivitis in the study population. The overall salivary bacterial load in saliva decreased with increasing salivary glucose concentration. Under HSG conditions, the bacterial count for 35 (83% of 42 species was significantly reduced, and relative bacterial frequencies in 27 species (64% were altered, as compared with LSG conditions. These alterations were stronger predictors of high salivary glucose than measures of oral disease, obesity, sleep or fitness.HSG was associated with a reduction in overall bacterial load and alterations to many relative bacterial frequencies in saliva when compared with LSG in samples from adolescents. We propose that hyperglycemia due to obesity and/or T2D results in HSG and subsequent acidification of the oral environment, leading to a generalized perturbation in the oral microbiome. This suggests a basis for the observation that hyperglycemia is associated with an increased risk of dental erosion, dental caries, and gingivitis. We conclude that HSG in adolescents may be predicted from salivary microbial diversity or frequency, and that the changes in the oral microbial composition seen in adolescents with developing metabolic disease may the consequence of hyperglycemia.

  5. Photo-acoustic sensor based on an inexpensive piezoelectric film transducer and an amplitude-stabilized single-mode external cavity diode laser for in vitro measurements of glucose concentration

    Science.gov (United States)

    Bayrakli, Ismail; Erdogan, Yasar Kemal

    2018-06-01

    The present paper focuses on development of a compact photo-acoustic sensor using inexpensive components for glucose analysis. An amplitude-stabilized wavelength-tunable single-mode external cavity diode laser operating around 1050 nm was realized and characterized for the use of laser beam as an excitation light source. In the established setup, a fine tuning range of 9 GHz was achieved. The glucose solution was obtained by diluting D-glucose in sterile water. The acoustic signal generated by the optical excitation was detected via a chip piezoelectric film transducer. A detection limit of 50 mM (900 mg/dl) was achieved. The device may be of great interest for its applications in medicine and health monitoring. The sensor is promising for non-invasive in vivo glucose measurements from interstitial fluid.

  6. Associations of fatty acids in cerebrospinal fluid with peripheral glucose concentrations and energy metabolism.

    Directory of Open Access Journals (Sweden)

    Reiner Jumpertz

    Full Text Available Rodent experiments have emphasized a role of central fatty acid (FA species, such as oleic acid, in regulating peripheral glucose and energy metabolism. Thus, we hypothesized that central FAs are related to peripheral glucose regulation and energy expenditure in humans. To test this we measured FA species profiles in cerebrospinal fluid (CSF and plasma of 32 individuals who stayed in our clinical inpatient unit for 6 days. Body composition was measured by dual energy X-ray absorptiometry and glucose regulation by an oral glucose test (OGTT followed by measurements of 24 hour (24EE and sleep energy expenditure (SLEEP as well as respiratory quotient (RQ in a respiratory chamber. CSF was obtained via lumbar punctures; FA concentrations were measured by liquid chromatography/mass spectrometry. As expected, FA concentrations were higher in plasma compared to CSF. Individuals with high concentrations of CSF very-long-chain saturated FAs had lower rates of SLEEP. In the plasma moderate associations of these FAs with higher 24EE were observed. Moreover, CSF monounsaturated long-chain FA (palmitoleic and oleic acid concentrations were associated with lower RQs and lower glucose area under the curve during the OGTT. Thus, FAs in the CSF strongly correlated with peripheral metabolic traits. These physiological parameters were most specific to long-chain monounsaturated (C16:1, C18:1 and very-long-chain saturated (C24:0, C26:0 FAs.Together with previous animal experiments these initial cross-sectional human data indicate that central FA species are linked to peripheral glucose and energy homeostasis.

  7. Indomethacin stimulates basal glucose production in humans without changes in concentrations of glucoregulatory hormones

    NARCIS (Netherlands)

    Corssmit, E. P.; Romijn, J. A.; Endert, E.; Sauerwein, H. P.

    1993-01-01

    1. To investigate whether indomethacin affects basal glucose production, we measured hepatic glucose production in six healthy postabsorptive subjects on two occasions: once after administration of indomethacin (150 mg orally) and once after administration of placebo. 2. Glucose production was

  8. Effects of hyperglycemia on glucose production and utilization in humans. Measurement with [3H]-2-, [3H]-3-, and [14C]-6-glucose

    International Nuclear Information System (INIS)

    Bell, P.M.; Firth, R.G.; Rizza, R.A.

    1986-01-01

    Studies with tritiated isotopes of glucose have demonstrated that hyperglycemia per se stimulates glucose utilization and suppresses glucose production in humans. These conclusions rely on the assumption that tritiated glucose provides an accurate measure of glucose turnover. However, if in the presence of hyperglycemia the isotope either loses its label during futile cycling or retains its label during cycling through glycogen, then this assumption is not valid. To examine this question, glucose utilization and glucose production rates were measured in nine normal subjects with a simultaneous infusion of [ 3 H]-2-glucose, an isotope that may undergo futile cycling but does not cycle through glycogen; [ 14 C]-6-glucose, an isotope that may cycle through glycogen but does not futile cycle; and [ 3 H]-3-glucose, an isotope that can both undergo futile cycling and cycle through glycogen. In the postabsorptive state at plasma glucose concentration of 95 mg X dl-1, glucose turnover determined with [ 14 C]-6-glucose (2.3 +/- 0.1 mg X kg-1 X min-1) was greater than that determined with [3 3 H]glucose (2.1 +/- 0.1 mg X kg-1 X min-1, P = 0.002) and slightly less than that determined with [ 3 H]-2-glucose (2.7 +/- 0.2 mg X kg-1 X min-1, P = 0.08). Plasma glucose was then raised from 95 to 135 to 175 mg X dl-1 while insulin secretion was inhibited, and circulating insulin, glucagon, and growth hormone concentrations were maintained constant by infusion of these hormones and somatostatin. Glucose production and utilization rates determined with [ 14 C]-6-glucose continued to be less than those determined with [ 3 H]-2-glucose and greater than those seen with [ 3 H]-3-glucose

  9. The effect of extremely high glucose concentrations on 21 routine chemistry and thyroid Abbott assays: interference study.

    Science.gov (United States)

    Çuhadar, Serap; Köseoğlu, Mehmet; Çinpolat, Yasemin; Buğdaycı, Güler; Usta, Murat; Semerci, Tuna

    2016-01-01

    Extremely high glucose concentrations have been shown to interfere with creatinine assays especially with Jaffe method in peritoneal dialysate. Because diabetes is the fastest growing chronic disease in the world, laboratories study with varying glucose concentrations. We investigated whether different levels of glucose spiked in serum interfere with 21 routine chemistry and thyroid assays at glucose concentrations between 17-51 mmol/L. Baseline (group I) serum pool with glucose concentration of 5.55 (5.44-5.61) mmol/L was prepared from patient sera. Spiking with 20% dextrose solution, sample groups were obtained with glucose concentrations: 17.09, 34.52, and 50.95 mmol/L (group II, III, IV, respectively). Total of 21 biochemistry analytes and thyroid tests were studied on Abbott c8000 and i2000sr with commercial reagents. Bias from baseline value was checked statistically and clinically. Creatinine increased significantly by 8.74%, 31.66%, 55.31% at groups II, III, IV, respectively with P values of < 0.001. At the median glucose concentration of 50.95 mmol/L, calcium, albumin, chloride and FT4 biased significantly clinically (-0.85%, 1.63%, 0.65%, 7.4% with P values 0.138, 0.214, 0.004, < 0.001, respectively). Remaining assays were free of interference. Among the numerous biochemical parameters studied, only a few parameters are affected by dramatically increased glucose concentration. The creatinine measurements obtained in human sera with the Jaffe alkaline method at high glucose concentrations should be interpreted with caution. Other tests that were affected with extremely high glucose concentrations were calcium, albumin, chloride and FT4, hence results should be taken into consideration in patients with poor diabetic control.

  10. Effect of feeding glucose, fructose, and inulin on blood glucose and insulin concentrations in normal ponies and those predisposed to laminitis.

    Science.gov (United States)

    Borer, K E; Bailey, S R; Menzies-Gow, N J; Harris, P A; Elliott, J

    2012-09-01

    Identification of ponies (Equus caballus) at increased risk of pasture-associated laminitis would aid in the prevention of the disease. Insulin resistance has been associated with laminitis and could be used to identify susceptible individuals. Insulin resistance may be diagnosed by feeding supplementary water-soluble carbohydrate (WSC) and measuring blood glucose and insulin concentrations. The aim of this study was to assess the glycemic and insulinemic responses of 7 normal (NP) and 5 previously laminitic (PLP), mixed breed, native UK ponies fed glucose, fructose, and inulin [1 g/(kg·d) for 3 d] or no supplementary WSC (control) in spring and fall after a 7-d adaptation to a pasture or hay diet. Blood samples were taken for 12 h after feeding on each day, and baseline and peak concentrations and area under the curve (AUC) for glucose and insulin were recorded. Linear mixed models were used for statistical analysis. Differences between PLP and NP groups were most marked after glucose feeding with differences in peak glucose (P = 0.02) and peak insulin (P = 0.016) concentrations. Season and diet adaptation also affected results. Peak concentrations of glucose and insulin occurred 2 to 4 h after WSC feeding. Peak insulin concentration was greater and more variable in fall, particularly in PLP adapted to fall pasture. Baseline glucose and insulin concentrations varied between individuals and with season and diet adaptation but were not greater in PLP than NP. Insulin AUC was greater in PLP than NP after feeding both glucose and fructose (P = 0.017), but there were no differences between PLP and NP in glucose AUC. Glycemic and insulinemic changes were less (P ≤ 0.05) after feeding fructose than glucose, although differences between PLP and NP were still evident. Minimal changes in glucose and insulin concentrations occurred after inulin feeding. Measurement of peak insulin 2 h after feeding of a single dose of glucose (1 g/kg) may be a simple and practical way to

  11. Blood Glucose and Insulin Concentrations after Octreotide Administration in Horses With Insulin Dysregulation.

    Science.gov (United States)

    Frank, N; Hermida, P; Sanchez-Londoño, A; Singh, R; Gradil, C M; Uricchio, C K

    2017-07-01

    Octreotide is a somatostatin analog that suppresses insulin secretion. We hypothesized that octreotide would suppress insulin concentrations in horses and that normal (N) horses and those with insulin dysregulation (ID) would differ significantly in their plasma glucose and insulin responses to administration of octreotide. Twelve horses, N = 5, ID = 7. Prospective study. An oral sugar test was performed to assign horses to N and ID groups. Octreotide (1.0 μg/kg IV) was then administered, and blood was collected at 0, 5, 10, 15, 20, 25, 30, 45, 60, 75, and 90 minute, and 2, 3, 4, 6, 8, 12, and 24 hour for measurement of glucose and insulin concentrations. Area under the curve (AUC) values were calculated. Mean AUC values for glucose and insulin did not differ between normal (n = 5) and ID (n = 7) groups after octreotide injection. Significant time (P glucose and insulin concentrations. A group × time interaction (P = .091) was detected for insulin concentrations after administration of octreotide, but the group (P = .33) effect was not significant. Octreotide suppresses insulin secretion, resulting in hyperglycemia, and then concentrations increase above baseline as glycemic control is restored. Our hypothesis that octreotide causes insulin concentrations to decrease in horses was supported, but differences between N and ID groups did not reach statistical significance when blood glucose and insulin responses were compared. The utility of an octreotide response test remains to be determined. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  12. Simultaneous measurement of glucose transport and utilization in the human brain

    Science.gov (United States)

    Shestov, Alexander A.; Emir, Uzay E.; Kumar, Anjali; Henry, Pierre-Gilles; Seaquist, Elizabeth R.

    2011-01-01

    Glucose is the primary fuel for brain function, and determining the kinetics of cerebral glucose transport and utilization is critical for quantifying cerebral energy metabolism. The kinetic parameters of cerebral glucose transport, KMt and Vmaxt, in humans have so far been obtained by measuring steady-state brain glucose levels by proton (1H) NMR as a function of plasma glucose levels and fitting steady-state models to these data. Extraction of the kinetic parameters for cerebral glucose transport necessitated assuming a constant cerebral metabolic rate of glucose (CMRglc) obtained from other tracer studies, such as 13C NMR. Here we present new methodology to simultaneously obtain kinetic parameters for glucose transport and utilization in the human brain by fitting both dynamic and steady-state 1H NMR data with a reversible, non-steady-state Michaelis-Menten model. Dynamic data were obtained by measuring brain and plasma glucose time courses during glucose infusions to raise and maintain plasma concentration at ∼17 mmol/l for ∼2 h in five healthy volunteers. Steady-state brain vs. plasma glucose concentrations were taken from literature and the steady-state portions of data from the five volunteers. In addition to providing simultaneous measurements of glucose transport and utilization and obviating assumptions for constant CMRglc, this methodology does not necessitate infusions of expensive or radioactive tracers. Using this new methodology, we found that the maximum transport capacity for glucose through the blood-brain barrier was nearly twofold higher than maximum cerebral glucose utilization. The glucose transport and utilization parameters were consistent with previously published values for human brain. PMID:21791622

  13. Glucose-stimulated insulin response in pregnant sheep following acute suppression of plasma non-esterified fatty acid concentrations

    Directory of Open Access Journals (Sweden)

    Sriskandarajah Nadarajah

    2004-09-01

    Full Text Available Abstract Background Elevated non-esterified fatty acids (NEFA concentrations in non-pregnant animals have been reported to decrease pancreatic responsiveness. As ovine gestation advances, maternal insulin concentrations fall and NEFA concentrations increase. Experiments were designed to examine if the pregnancy-associated rise in NEFA concentration is associated with a reduced pancreatic sensitivity to glucose in vivo. We investigated the possible relationship of NEFA concentrations in regulating maternal insulin concentrations during ovine pregnancy at three physiological states, non-pregnant, non-lactating (NPNL, 105 and 135 days gestational age (dGA, term 147+/- 3 days. Methods The plasma concentrations of insulin, growth hormone (GH and ovine placental lactogen (oPL were determined by double antibody radioimmunoassay. Insulin responsiveness to glucose was measured using bolus injection and hyperglycaemic clamp techniques in 15 non-pregnant, non-lactating ewes and in nine pregnant ewes at 105 dGA and near term at 135 dGA. Plasma samples were also collected for hormone determination. In addition to bolus injection glucose and insulin Area Under Curve calculations, the Mean Plasma Glucose Increment, Glucose Infusion Rate and Mean Plasma Insulin Increment and Area Under Curve were determined for the hyperglycaemic clamp procedures. Statistical analysis of data was conducted with Students t-tests, repeated measures ANOVA and 2-way ANOVA. Results Maternal growth hormone, placental lactogen and NEFA concentrations increased, while basal glucose and insulin concentrations declined with advancing gestation. At 135 dGA following bolus glucose injections, peak insulin concentrations and insulin area under curve (AUC profiles were significantly reduced in pregnant ewes compared with NPNL control ewes (p Conclusions Results suggest that despite an acute suppression of circulating NEFA concentrations during pregnancy, the associated steroids and hormones

  14. [A comparison of post-surgical plasma glucose levels in patients on fluids with different glucose concentrations].

    Science.gov (United States)

    Martínez Carapeto, Isabel; López Castilla, José Domingo; Fresneda Gutiérrez, Reyes

    2017-11-11

    To compare plasma glucose levels and incidence of hyperglycaemia in the post-operative period after general surgery using fluids with different glucose. A randomised, open-label, non-blind, clinical trial was conducted on patients admitted to Paediatric Intensive Care Unit after elective surgery. The inclusion criteria were from 6 months to 14 years of age, with a weight greater than 6kg, onset glucose level >60mg/dL, and a signed informed consent, with no oral intake and maintenance intravenous fluid therapy using fluids with 3.3% or 5% glucose. Plasma glucose levels were measured before surgery, on admission, and 8, 24, and 48h, with the mean glucose levels and incidence of hyperglycaemia (glucose level >150mg/dL) in both groups being compared. A total of 60 patients received glucose/saline 1/3 (51mEq/L sodium and 33g/L glucose), and 70 glucose/saline 5/0.9% (154mEq/L sodium and 50g/L glucose). Mean glucose levels were higher in the group receiving glucose 5%, with no statistical difference. There was no significant difference in the incidence of hyperglycaemia; 8h: 26% in the 3.3% group vs. 21.3% in the 5% group (P=.63); 24h: 20% vs. 22.7% (P=.8); and 48h: 19% vs. 23.1% (P=.78). The use of fluids with 3.3% glucose in the post-operative period of general surgery maintains mean glucose levels in a similar range to that of patients receiving fluids with 5% glucose, with no difference in the incidence of hyperglycaemia. Copyright © 2017. Publicado por Elsevier España, S.L.U.

  15. Effects of elevated glucose concentration on cultured bovine retinal endothelial (BRE) cells

    International Nuclear Information System (INIS)

    Capetandes, A.; Gerritsen, M.E.

    1986-01-01

    Salient clinical features of diabetic retinopathy include capillary microaneurysm and neovascularization, which progress with the severity of the disease. It has been suggested that exposure of the retinal vascular cells to high glucose concentrations may play a causative role in the retinopathy. In the present study, the effects of variant media glucose concentrations on BRE cell growth were determined. Normal growth curves were obtained with glucose concentrations of 100, 450 and 600 mg%, but the replication rate was decreased with 600 mg%. To determine if elevated glucose concentrations also altered DNA synthesis, BRE cells cultivated with 100 and 600 mg% glucose demonstrated increased thymidine uptake and total DNA content compared to the 100 mg% group. Furthermore, vacuolation and increased cell diameter occurred in BRE cells cultivated 600 mg% compared to 100 mg% glucose. In conclusion, increases in media glucose concentrations result in a decreased cellular replication rate, increased DNA synthesis and increased cell diameter during the log phase of growth

  16. [Influence of an infusion of 5- or 20% glucose solution on blood glucose and inorganic phosphate concentrations in dairy cows].

    Science.gov (United States)

    Aldaek, T A A; Failing, K; Wehrend, A; Klymiuk, M C

    2011-01-01

    The study was performed to evaluate the influence of an intravenous infusion of 5% and 20% dextrose solution on the plasma concentration of glucose and inorganic phosphate in healthy, dairy cows. Ten healthy, lactating, nonpregnant 3 to 6 year-old Holstein-Friesian cows were included in this investigation. The daily milk yield was 20.3±2.7 liters. Blood plasma concentrations of inorganic phosphate and glucose were determined before, during, immediately and 60 minutes after infusion of 0.9% physiological saline, 5% or 20% dextrose solution. A statistically significant influence of dextrose infusion on blood glucose concentration was observed. After 20% dextrose infusion (200 g dextrose) the blood glucose concentration increased by approximately 13.26 mmol/l. The administration of 5% dextrose solution (50 g dextrose) yielded an increase of blood glucose concentration by 3.31 mmol/l. There was no significant correlation between plasma inorganic phosphate concentrations and infusion of 0.9% saline, 5% or 20% dextrose solution. Intravenous administration of 1000 ml of 5% or 20% dextrose solution does not induce a lasting plasma phosphate reduction and is suitable for elevating the blood glucose concentration.

  17. Raised concentrations of lipid peroxidation products (LPO in pregnant women with impaired glucose tolerance

    Directory of Open Access Journals (Sweden)

    Krzysztof C. Lewandowski

    2014-06-01

    Full Text Available introduction. Lipid peroxidation (LPO results from oxidative damage to membrane lipids. Whereas LPO rises in normal pregnancy, the effect of gestational diabetes mellitus (GDM on this process has not been clearly defined. materials and method. Fasting blood concentrations of malondialdehyde+4-hydroxyalkenals (MDA+4-HDA, as LPO index, TNFa soluble receptors (sTNF-R1 and sTNF-R2, and soluble adhesion molecules (sICAM-1, sVCAM-1, were measured in 51 women at 28 weeks of gestation. The women were divided according to the results of 50.0 g glucose challenge test (GCT and 75.0 g oral glucose tolerance test (OGTT: Controls (n=20, normal responses to both GCT and OGTT; Intermediate Group (IG (n=15, abnormal GCT but normal OGTT; GDM group (n=16, abnormal both GCT and OGTT. results. Glucose concentrations in women diagnosed with GDM were within the range of impaired glucose tolerance. There were no significant differences in concentrations of either TNF a soluble receptors R1 and R2, or sICAM-1 or sVCAM-1. LPO concentrations [MDA+4-HDA (nmol/mg protein] were significantly higher in women with GDM than in the other two groups [64.1±24.3 (mean±SD, 39.3±23.1, 47.0±18.1, for GDM, IG and Controls, respectively; p<0.05]. In multivariate analysis, the only significant independent correlation was between LPO level and glucose at 120 minutes of OGTT (rs=0.42; p=0.009. conclusions. Oxidative damage to membrane lipids is increased in GDM and might result directly from hyperglycaemia. Physiological significance of this phenomenon remains to be elucidated.

  18. Low Red Blood Cell Vitamin C Concentrations Induce Red Blood Cell Fragility: A Link to Diabetes Via Glucose, Glucose Transporters, and Dehydroascorbic Acid

    Directory of Open Access Journals (Sweden)

    Hongbin Tu

    2015-11-01

    Full Text Available Strategies to prevent diabetic microvascular angiopathy focus on the vascular endothelium. Because red blood cells (RBCs are less deformable in diabetes, we explored an original concept linking decreased RBC deformability to RBC ascorbate and hyperglycemia. We characterized ascorbate concentrations from human and mouse RBCs and plasma, and showed an inverse relationship between RBC ascorbate concentrations and deformability, measured by osmotic fragility. RBCs from ascorbate deficient mice were osmotically sensitive, appeared as spherocytes, and had decreased β-spectrin. These aberrancies reversed with ascorbate repletion in vivo. Under physiologic conditions, only ascorbate's oxidation product dehydroascorbic acid (DHA, a substrate for facilitated glucose transporters, was transported into mouse and human RBCs, with immediate intracellular reduction to ascorbate. In vitro, glucose inhibited entry of physiologic concentrations of dehydroascorbic acid into mouse and human RBCs. In vivo, plasma glucose concentrations in normal and diabetic mice and humans were inversely related to respective RBC ascorbate concentrations, as was osmotic fragility. Human RBC β-spectrin declined as diabetes worsened. Taken together, hyperglycemia in diabetes produced lower RBC ascorbate with increased RBC rigidity, a candidate to drive microvascular angiopathy. Because glucose transporter expression, DHA transport, and its inhibition by glucose differed for mouse versus human RBCs, human experimentation is indicated.

  19. Effect of the fructose and glucose concentration on the rheological ...

    African Journals Online (AJOL)

    The objective of this work was to study the effect of fructose and glucose content on the rheological behavior of syrups. Initially, high fructose syrup from the fructans present in leaves, bases and head of Agave tequilana Weber blue was obtained. Then, its contents of moisture, ash, fructose, glucose and direct and total ...

  20. Influences of saccharides types and initial glucose concentration on ...

    African Journals Online (AJOL)

    Tests on agar slants and in agitated shake flasks using glucose, sucrose and lactose media exhibited that the cellulose producer, Gluconacetobacterxylinus DSM 46604 resembled good growth on glucose and produced cellulose. However, there was negligible growth on sucrose and lactose media. Further experiments ...

  1. Steady-state cerebral glucose concentrations and transport in the human brain

    OpenAIRE

    Gruetter, R.; Ugurbil, K.; Seaquist, E. R.

    1998-01-01

    Understanding the mechanism of brain glucose transport across the blood- brain barrier is of importance to understanding brain energy metabolism. The specific kinetics of glucose transport nave been generally described using standard Michaelis-Menten kinetics. These models predict that the steady- state glucose concentration approaches an upper limit in the human brain when the plasma glucose level is well above the Michaelis-Menten constant for half-maximal transport, K(t). In experiments wh...

  2. Effect of the fructose and glucose concentration on the rheological ...

    African Journals Online (AJOL)

    Jose Luis Montañez Soto

    2013-03-20

    Mar 20, 2013 ... C.P. 38010. Celaya, Guanajuato, México. ... In quality control, knowledge of the rheological behavior of a fluid is ... intermediary products during manufacturing and of course, of ... fructose and 45%, glucose (Arancia, Mexico).

  3. A Lab-on-a-Chip-Based Non-Invasive Optical Sensor for Measuring Glucose in Saliva

    Directory of Open Access Journals (Sweden)

    Dong Geon Jung

    2017-11-01

    Full Text Available A lab-on-a-chip (LOC-based non-invasive optical sensor for measuring glucose in saliva was fabricated. Existing glucose sensors utilizing blood require acquisition of a blood sample by pricking the finger, which is painful and inconvenient. To overcome these limitations, we propose a non-invasive glucose sensor with LOC, micro-electro-mechanical system and optical measurement technology. The proposed sensor for measuring glucose in saliva involves pretreatment, mixing, and measurement on a single tiny chip. Saliva containing glucose and glucose oxidase for glucose oxidation are injected through Inlets 1 and 2, respectively. Next, H2O2 is produced by the reaction between glucose and glucose oxidase in the pretreatment part. The saliva and generated H2O2 are mixed with a colorizing agent injected through Inlet 3 during the mixing part and the absorbance of the colorized mixture is measured in the measurement part. The absorbance of light increases as a function of glucose concentration at a wavelength of 630 nm. To measure the absorbance of the colorized saliva, a light-emitting diode with a wavelength of 630 nm and a photodiode were used during the measurement part. As a result, the measured output current of the photodiode decreased as glucose concentration in the saliva increased.

  4. Non-contact optical sensor for detection of glucose concentration using a magneto-optic effect

    Science.gov (United States)

    Ozana, Nisan; Beiderman, Yevgeny; Anand, Arun; Javidi, Baharam; Polani, Sagi; Schwarz, Ariel; Shemer, Amir; García, Javier; Zalevsky, Zeev

    2016-03-01

    In this paper we aim to experimentally verify a speckle based technique for non-contact measurement of glucose concentration in blood stream while the vision for the final device aims to contain a single wristwatch-style device containing an AC (alternating) electro-magnet generated by a solenoid, a laser and a camera. The experiments presented in work are performed in-vitro in order to verify the effects that are responsible for the operation principle. When a glucose substance is inserted into a solenoid generating an alternating magnetic field it exhibits Faraday rotation which affects the temporal changes of the secondary speckle patterns distribution. The temporal frequency resulting from the AC magnetic field was found to have a lock-in amplification role which increased the observability of the relatively small magneto-optic effect. Experimental results to support the proposed concept are presented.

  5. Noncontact speckle-based optical sensor for detection of glucose concentration using magneto-optic effect

    Science.gov (United States)

    Ozana, Nisan; Beiderman, Yevgeny; Anand, Arun; Javidi, Baharam; Polani, Sagi; Schwarz, Ariel; Shemer, Amir; Garcia, Javier; Zalevsky, Zeev

    2016-06-01

    We experimentally verify a speckle-based technique for noncontact measurement of glucose concentration in the bloodstream. The final device is intended to be a single wristwatch-style device containing a laser, a camera, and an alternating current (ac) electromagnet generated by a solenoid. The experiments presented are performed in vitro as proof of the concept. When a glucose substance is inserted into a solenoid generating an ac magnetic field, it exhibits Faraday rotation, which affects the temporal changes of the secondary speckle pattern distributions. The temporal frequency resulting from the ac magnetic field was found to have a lock-in amplification role, which increased the observability of the relatively small magneto-optic effect. Experimental results to support the proposed concept are presented.

  6. Continuous tissue glucose monitoring correlates with measurement of intermittent capillary glucose in patients with distributive shock.

    Science.gov (United States)

    Ballesteros, D; Martínez, Ó; Blancas Gómez-Casero, R; Martín Parra, C; López Matamala, B; Estébanez, B; Chana, M

    2015-10-01

    Intermittent glycemic measurements in patients admitted to the intensive care unit (ICU) can result in episodes of severe hypoglycemia or in a poor control of glycemia range. We designed a study to assess accuracy and reliability of continuous monitoring of tissue glucose for patients with distributive shock. Consecutive patients admitted to the ICU with a diagnosis of distributive shock and the need of insulin infusion for glycemic control were included in the study. These patients were implanted a Continuous Glucose Control Monitoring System (CGMS) with the sensor inserted subcutaneously into the abdominal wall. CGMS values were recorded every 5min. Capillary glucose (CG) was monitored for adjusting insulin perfusion according to the ICU protocol. Correlation between both methods was assessed. A total of 11,673 CGMS and 348 CG values were recorded. In five patients, CGMS failed to detect tissue glucose. A glucose value <3.33mmol/l (<60mg/dl) was observed in 3.6% of CGMS and in 0.29% CG values. 295 pairs of measurements were included in the statistical analysis for correlation assessment. The intraclass correlation coefficient was 0.706. The Pearson correlation coefficient was 0.71 (p<0.0001, 95% CI 0.65-0.76). The mean of differences between both measurement methods was 0.22mmol/l (3.98mg/dl) (95% CI 0.66-7.31). When the Continuous Glucose Control Monitoring System (CGMS) is able to obtain data (75% of the patients), there is correlation between the values obtained by this method and capillary blood glucose in patients with distributive shock. CGMS can detect more episodes of glycemic excursions outside the normal range than intermittent capillary glucose monitoring. Variables that may impair glucose metabolism and peripheral soft tissues perfusion could impair CGMS measurements. Copyright © 2014 Elsevier España, S.L.U. and SEMICYUC. All rights reserved.

  7. Self-monitoring of blood glucose measurements and glycaemic ...

    African Journals Online (AJOL)

    Background. Intensive diabetes management requires intensive insulin treatment and self-monitoring of blood glucose (SMBG) measurements to obtain immediate information on the status of the blood glucose level and to obtain data for pattern analysis on which meal planning, insulin and lifestyle adjustments can be ...

  8. Threshold concentration of glucose for bacterial growth in soil

    NARCIS (Netherlands)

    Reischke, Stephanie; Kumar, Manoj G.K.; Baath, Erland

    The activity of heterotrophic soil microorganisms is usually limited by the availability and quality of carbon (C). Adding organic substances will thus trigger a microbial response. We studied the response in bacterial growth and respiration after the addition of low amounts of glucose. First we

  9. The effects of oxygen level and glucose concentration on the metabolism of porcine TMJ disc cells.

    Science.gov (United States)

    Cisewski, S E; Zhang, L; Kuo, J; Wright, G J; Wu, Y; Kern, M J; Yao, H

    2015-10-01

    To determine the combined effect of oxygen level and glucose concentration on cell viability, ATP production, and matrix synthesis of temporomandibular joint (TMJ) disc cells. TMJ disc cells were isolated from pigs aged 6-8 months and cultured in a monolayer. Cell cultures were preconditioned for 48 h with 0, 1.5, 5, or 25 mM glucose DMEM under 1%, 5%, 10%, or 21% O2 level, respectively. The cell viability was measured using the WST-1 assay. ATP production was determined using the Luciferin-Luciferase assay. Collagen and proteoglycan synthesis were determined by measuring the incorporation of [2, 3-(3)H] proline and [(35)S] sulfate into the cells, respectively. TMJ disc cell viability significantly decreased (P oxygen levels significantly increased viability (P oxygen levels significantly reduced ATP production (P oxygen was significant in regards to cell viability (P oxygen are important, glucose is the limiting nutrient for TMJ disc cell survival. At low oxygen levels, the production of ATP, collagen, and proteoglycan are severely inhibited. These results suggest that steeper nutrient gradients may exist in the TMJ disc and it may be vulnerable to pathological events that impede nutrient supply. Copyright © 2015 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  10. Impact of buccal glucose spray, liquid sugars and dextrose tablets on the evolution of plasma glucose concentration in healthy persons.

    Science.gov (United States)

    Chlup, Rudolf; Zapletalova, Jana; Peterson, Karolina; Poljakova, Iveta; Lenhartova, Eva; Tancred, Adam; Perera, Russel; Smital, Jan

    2009-09-01

    The purpose of this prospective controlled trial was to assess the efficacy of three commercially available glucose products, (1) buccal glucose spray, (2) liquid sugars, and (3) dextrose tablet, on the evolution of plasma glucose concentration (PG). Sixteen healthy volunteers aged 21.8 +/- 0.78 y (mean +/- SE), BMI 23.5 +/- 0.84 kg/m(2), tested their PG over the course of 3 sets of 4 sessions (S) each: S(0)-control fasting, S(1)-buccal administration of 10 glucose spray-doses (0.84 g of glucose) without swallowing; S(2-) consumption of 1 sachet (13 ml) of liquid sugar (ca. 5.2 g glucose, 5.2 g fructose, 5.2 g sucrose); S(3-) consumption of one dextrose tablet (6 g). PG was tested in finger-prick capillary blood using a personal glucometer Linus at the start, and at 5, 10, 15, 20 and 30 min. The means of 3 respective sessions for each of the 16 subjects were analyzed. The Wilcoxon signed rank test revealed no significant differences between changes in the mean PG at the start vs. 5-minute interval either in control, or any intervention sessions. Analysis of regression coefficients after 30 min compared to the control session, demonstrated an increase in PG with the sachet of liquid sugars (0.068 mmol/l/min, p = 0.001) which was greater than a single dextrose tablet (0.052 mmol/l/min, p = 0.002), but no significant PG increase was found after buccal glucose spray. Liquid sugars or dextrose tablets, but not the buccal glucose spray, are effective means to increase PG within 10 minutes after ingestion.

  11. In-vitro performance of the Enlite Sensor in various glucose concentrations during hypobaric and hyperbaric conditions.

    Science.gov (United States)

    Adolfsson, Peter; Ornhagen, Hans; Eriksson, Bengt M; Gautham, Raghavendhar; Jendle, Johan

    2012-11-01

    There is a need for reliable methods of glucose measurement in different environmental conditions. The objective of this in vitro study was to evaluate the performance of the Enlite® Sensor when connected to either the iPro™ Continuous Glucose Monitor recording device or the Guardian® REAL-Time transmitting device, in hypobaric and hyperbaric conditions. Sixteen sensors connected to eight iPro devices and eight Guardian REAL-Time devices were immersed in three beakers containing separate glucose concentrations: 52, 88, and 207 mg/dl (2.9, 4.9, and 11.3 mmol/liter). Two different pressure tests were conducted: a hypobaric test, corresponding to maximum 18000 ft/5500 m height, and a hyperbaric test, corresponding to maximum 100 ft/30 m depth. The linearity of the sensor signals in the different conditions was evaluated. The sensors worked continuously, and the sensor signals were collected without interruption at all pressures tested. When comparing the input signals for glucose (ISIGs) and the different glucose concentrations during altered pressure, linearity (R(2)) of 0.98 was found. During the hypobaric test, significant differences (p hyperbaric test, no differences were found. The Enlite Sensors connected to either the iPro or the Guardian REAL-Time device provided values continuously. In hyperbaric conditions, no significant differences were seen during changes in ambient pressure; however, during hypobaric conditions, the ISIG was significantly different in the low and high glucose concentrations. © 2012 Diabetes Technology Society.

  12. Peripheral Blood Transcriptomic Signatures of Fasting Glucose and Insulin Concentrations

    Science.gov (United States)

    Chen, Brian H.; Hivert, Marie-France; Peters, Marjolein J.; Pilling, Luke C.; Hogan, John D.; Pham, Lisa M.; Harries, Lorna W.; Fox, Caroline S.; Bandinelli, Stefania; Dehghan, Abbas; Hernandez, Dena G.; Hofman, Albert; Hong, Jaeyoung; Joehanes, Roby; Johnson, Andrew D.; Munson, Peter J.; Rybin, Denis V.; Singleton, Andrew B.; Uitterlinden, André G.; Ying, Saixia; Melzer, David; Levy, Daniel; van Meurs, Joyce B.J.; Ferrucci, Luigi; Florez, Jose C.; Dupuis, Josée

    2016-01-01

    Genome-wide association studies (GWAS) have successfully identified genetic loci associated with glycemic traits. However, characterizing the functional significance of these loci has proven challenging. We sought to gain insights into the regulation of fasting insulin and fasting glucose through the use of gene expression microarray data from peripheral blood samples of participants without diabetes in the Framingham Heart Study (FHS) (n = 5,056), the Rotterdam Study (RS) (n = 723), and the InCHIANTI Study (Invecchiare in Chianti) (n = 595). Using a false discovery rate q fasting glucose and 433 transcripts associated with fasting insulin levels after adjusting for age, sex, technical covariates, and complete blood cell counts. Among the findings, circulating IGF2BP2 transcript levels were positively associated with fasting insulin in both the FHS and RS. Using 1000 Genomes–imputed genotype data, we identified 47,587 cis-expression quantitative trait loci (eQTL) and 6,695 trans-eQTL associated with the 433 significant insulin-associated transcripts. Of note, we identified a trans-eQTL (rs592423), where the A allele was associated with higher IGF2BP2 levels and with fasting insulin in an independent genetic meta-analysis comprised of 50,823 individuals. We conclude that integration of genomic and transcriptomic data implicate circulating IGF2BP2 mRNA levels associated with glucose and insulin homeostasis. PMID:27625022

  13. Glucose uptake and transport in contracting, perfused rat muscle with different pre-contraction glycogen concentrations

    DEFF Research Database (Denmark)

    Hespel, P; Richter, Erik

    1990-01-01

    1. Glucose uptake and transport, muscle glycogen, free glucose and glucose-6-phosphate concentrations were studied in perfused resting and contracting rat skeletal muscle with different pre-contraction glycogen concentrations. Rats were pre-conditioned by a combination of swimming exercise and diet......, resulting in either low (glycogen-depleted rats), normal (control rats) or high (supercompensated rats) muscle glycogen concentrations at the time their hindlimbs were perfused. 2. Compared with control rats, pre-contraction muscle glycogen concentration was approximately 40% lower in glycogen-depleted rats......, whereas it was 40% higher in supercompensated rats. Muscle glycogen break-down correlated positively (r = 0.76; P less than 0.001) with pre-contraction muscle glycogen concentration. 3. Glucose uptake during contractions was approximately 50% higher in glycogen-depleted hindquarters than in control...

  14. Effects of fasting on plasma catecholamine, corticosterone and glucose concentrations under basal and stress conditions in individual rats

    NARCIS (Netherlands)

    de Boer, S.F.; Koopmans, S.J.; Slangen, J L; Van der Gugten, J

    Plasma noradrenaline (NA), adrenaline (A), corticosterone (CS) and glucose concentrations were determined in blood sampled via a cardiac catheter from freely moving male rats under ad lib fed and 24 hr food deprived conditions using a repeated measures within-subject design. Resting plasma NA and

  15. Glucose transport and milk secretion during manipulated plasma insulin and glucose concentrations and during LPS-induced mastitis in dairy cows.

    Science.gov (United States)

    Gross, J J; van Dorland, H A; Wellnitz, O; Bruckmaier, R M

    2015-08-01

    In dairy cows, glucose is essential as energy source and substrate for milk constituents. The objective of this study was to investigate effects of long-term manipulated glucose and insulin concentrations in combination with a LPS-induced mastitis on mRNA abundance of glucose transporters and factors involved in milk composition. Focusing on direct effects of insulin and glucose without influence of periparturient endocrine adaptations, 18 dairy cows (28 ± 6 weeks of lactation) were randomly assigned to one of three infusion treatments for 56 h (six animals each). Treatments included a hyperinsulinemic hypoglycaemic clamp (HypoG), a hyperinsulinemic euglycaemic clamp (EuG) and a control group (NaCl). After 48 h of infusions, an intramammary challenge with LPS from E. coli was performed and infusions continued for additional 8 h. Mammary gland biopsies were taken before, at 48 (before LPS challenge) and at 56 h (after LPS challenge) of infusion, and mRNA abundance of genes involved in mammary gland metabolism was measured by RT-qPCR. During the 48 h of infusions, mRNA abundance of glucose transporters GLUT1, 3, 4, 8, 12, SGLT1, 2) was not affected in HypoG, while they were downregulated in EuG. The mRNA abundance of alpha-lactalbumin, insulin-induced gene 1, κ-casein and acetyl-CoA carboxylase was downregulated in HypoG, but not affected in EuG. Contrary during the intramammary LPS challenge, most of the glucose transporters were downregulated in NaCl and HypoG, but not in EuG. The mRNA abundance of glucose transporters in the mammary gland seems not to be affected by a shortage of glucose, while enzymes and milk constituents directly depending on glucose as a substrate are immediately downregulated. During LPS-induced mastitis in combination with hypoglycaemia, mammary gland metabolism was more aligned to save glucose for the immune system compared to a situation without limited glucose availability during EuG. Journal of Animal Physiology and Animal

  16. Plasma glucose, cholesterol, triglyceride, and glycerol concentrations in the postmature rabbit.

    Science.gov (United States)

    Harlow, A C; Roux, J F; Shapiro, M I

    1980-02-15

    Plasma cholesterol, triglycerides, glycerol, and glucose concentrations were measured in term and postmature rabbits. The data show that the term and postmature mothers have significantly higher glycemia than their fetuses. However, triglyceride and cholesterol concentrations are lower in the postmature mother than in her fetus. Postmature fetuses are characterized by very high plasma triglyceride and cholesterol concentrations. The results demonstrate that postmaturity is accompanied by maternal and fetal lipid metabolic changes related to a decrease in the transfer of maternal fatty acids through the placenta and to a diminution in fetal liver glucose utilization. The postmature fetus is then in a relative state of fasting and must rely on its own supply of fuel (glycogen and lipids) to provide cells for growth and survival. The maternal metabolic changes can possibly be explained by a decreased utilization of maternal substrates by the fetus, the placenta becoming insufficient. The close interrelationship of fetal and maternal lipid metabolism with the activity of the placenta suggests that an accurate knowledge of the metabolic changes taking place in the fetus during alteration of the maternal environment is indispensable to the understanding of the short- and long-term effects of maternal disease on the fetus.

  17. Comparison of glucose concentration and glucose absorption from the GI-tract in pigs in whole blood and in plasma

    DEFF Research Database (Denmark)

    Theil, Peter Kappel; Jørgensen, Henry; Larsen, Torben

    2010-01-01

    using a biosensitive electrode (Exp. 1) or a standard colourimetric method (Exp. 2). In general, glucose measured in whole blood was 7-11% lower than in plasma at low glucose levels (3.5-5 mM), whereas the methods agreed well at high glucose levels (10-14 mM). Evaluation of the regression lines between......The present investigation was undertaken to compare glucose absorption from the gastro-intestinal tract quantified in either whole blood or plasma using the arterio-venous differences and portal blood flow measurements. Pigs were surgically modified with catheters in the portal vein...... three different diets with similar contents of starch (470-506 g/kg DM). The diets in both studies differed regarding amount and solubility of fibre. Blood samples were collected repeatedly 0-10 h after morning feeding. Glucose was measured in whole blood using a glucometer (Accu-Chek®) and in plasma...

  18. Blood glucose measurement with multiple quantum cascade lasers using hollow-optical fiber-based ATR spectroscopy

    Science.gov (United States)

    Yoshioka, K.; Kino, S.; Matsuura, Y.

    2018-02-01

    For non-invasive blood glucose measurement, a measurement system based on mid-infrared ATR spectroscopy equipped with a combination of a QCL as a light source and a hollow-optical fiber as a beam delivery medium is developed. Firstly the measurement sensitivity of the system is evaluated by using glucose solutions and the result shows a significant correlation between optical absorbance and solution concentration. It is also confirmed that the system has a sensitivity that is enough for blood glucose measurement. Then optical absorption of human lips in the mid-infrared wavelength region is measured using a QCL with a wavenumber of 1080 cm-1 where human tissue exhibits strong absorption of glucose and its metabolites. As a result, the measured absorption follows the change of blood glucose well with a time delay of around 10 minutes and correlation factor between the absorbance and the blood glucose level is 0.42.

  19. A glucose concentration and temperature sensor based on long period fiber gratings induced by electric-arc discharge

    Science.gov (United States)

    Du, Chao; Wang, Qi

    2017-10-01

    As one of the key parameters in biological and chemical reactions, glucose concentration objectively reflects the characteristics of reactions, so the real-time monitoring of glucose concentration is important in the field of biochemical. Meanwhile, the influence from temperature should be considered. The fiber sensors have been studied extensively for decades due to the advantages of small size, immunity to electromagnetic interference and high sensitivity, which are suitable for the application of biochemical sensing. A long period fiber grating (LPFG) sensor induced by electric-arc discharge has been fabricated and demonstrated for simultaneous measurement of glucose concentration and temperature. The proposed sensor was fabricated by inscribing a sing mode fiber (SMF) with periodic electric-arc discharge technology. During the fabrication process, the electric-arc discharge technology was produced by a commercial fusion splicer, and the period of inscribed LPFG was determined by the movement of translation stages. A serials of periodic geometrical deformations would be formed in SMF after the fabrication, and the discharge intensity and discharge time can be adjusted though the fusion splicer settings screen. The core mode can be coupled into the cladding modes at certain wavelength when they satisfy the phase-matching conditions, and there will be several resonance dips in the transmission spectrum in LPFG. The resonance dips formed by the coupling between cladding modes and core mode have different sensitivity responses, so the simultaneous measurement for multi-parameter can be realized by monitoring the wavelength shifts of the resonance dips. Compared with the LPFG based on conventional SMF, the glucose concentration sensitivity has been obviously enhanced by etching the cladding with hydrofluoric acid solution. Based on the independent measured results, a dual-parameter measurement matrix has been built for signal demodulation. Because of the easy

  20. Precision and accuracy of blood glucose measurements using three different instruments.

    Science.gov (United States)

    Nowotny, B; Nowotny, P J; Strassburger, K; Roden, M

    2012-02-01

    Assessment of insulin sensitivity by dynamic metabolic tests such as the hyperinsulinemic euglycemic clamp critically relies on the reproducible and fast measurement of blood glucose concentrations. Although various instruments have been developed over the last decades, little is known as to the accuracy and comparability. We therefore compared the best new instrument with the former gold standard instruments to measure glucose concentrations in metabolic tests. Fasting blood samples of 15 diabetic and 10 healthy subjects were collected into sodium-fluoride tubes, spiked with glucose (0, 2.8, 6.9 and 11.1 mmol/l) and measured either as whole blood (range 3.3-26.3 mmol/l) or following centrifugation as plasma (range 3.9-32.0 mmol/l). Plasma samples were analyzed in the YSI-2300 STAT plus (YSI), EKF Biosen C-Line (EKF) and the reference method, Beckman Glucose analyzer-II (BMG), whole blood samples in EKF instruments with YSI as reference method. The average deviation of the EKF from the reference, BMG, was 3.0 ± 3.5% without any concentration-dependent variability. Glucose measurements by YSI were in good agreement with that by BMG (plasma) and EKF (plasma and whole blood) up to concentrations of 13.13 mmol/l (0.5 ± 3.7%), but deviation increased to -6.2 ± 3.8% at higher concentrations. Precision (n = 6) was ±2.2% (YSI), ±3.9% (EKF) and ±5.2% (BMG). The EKF instrument is comparable regarding accuracy and precision to the reference method BMG and can be used in metabolic tests, while the YSI showed a systematic shift at higher glucose concentrations. Based on these results we decided to replace BMG with EKF instrument in metabolic tests. © 2012 The Authors. Diabetic Medicine © 2012 Diabetes UK.

  1. Clinical assessment of the accuracy of blood glucose measurement devices.

    Science.gov (United States)

    Pfützner, Andreas; Mitri, Michael; Musholt, Petra B; Sachsenheimer, Daniela; Borchert, Marcus; Yap, Andrew; Forst, Thomas

    2012-04-01

    Blood glucose meters for patient self-measurement need to comply with the accuracy standards of the ISO 15197 guideline. We investigated the accuracy of the two new blood glucose meters BG*Star and iBG*Star (Sanofi-Aventis) in comparison to four other competitive devices (Accu-Chek Aviva, Roche Diagnostics; FreeStyle Freedom Lite, Abbott Medisense; Contour, Bayer; OneTouch Ultra 2, Lifescan) at different blood glucose ranges in a clinical setting with healthy subjects and patients with type 1 and type 2 diabetes. BGStar and iBGStar are employ dynamic electrochemistry, which is supposed to result in highly accurate results. The study was performed on 106 participants (53 female, 53 male, age (mean ± SD): 46 ± 16 years, type 1: 32 patients, type 2: 34 patients, and 40 healthy subjects). Two devices from each type and strips from two different production lots were used for glucose assessment (∼200 readings/meter). Spontaneous glucose assessments and glucose or insulin interventions under medical supervision were applied to perform measurements in the different glucose ranges in accordance with the ISO 15197 requirements. Sample values 400 mg/dL were prepared by laboratory manipulations. The YSI glucose analyzer (glucose oxidase method) served as the standard reference method which may be considered to be a limitation in light of glucose hexokinase-based meters. For all devices, there was a very close correlation between the glucose results compared to the YSI reference method results. The correlation coefficients were r = 0.995 for BGStar and r = 0.992 for iBGStar (Aviva: 0.995, Freedom Lite: 0.990, Contour: 0.993, Ultra 2: 0.990). Error-grid analysis according to Parkes and Clarke revealed both 100% of the readings to be within the clinically acceptable areas (Clarke: A + B with BG*Star (100 + 0), Aviva (97 + 3), and Contour (97 + 3); and 99.5% with iBG*Star (97.5 + 2), Freedom Lite (98 + 1.5), and Ultra 2 (97.5 + 2

  2. A simple method for measuring glucose utilization of insulin-sensitive tissues by using the brain as a reference

    International Nuclear Information System (INIS)

    Namba, Hiroki; Nakagawa, Keiichi; Iyo, Masaomi; Fukushi, Kiyoshi; Irie, Toshiaki

    1994-01-01

    A simple method, without measurement of the plasma input function, to obtain semiquantitative values of glucose utilization in tissues other than the brain with radioactive deoxyglucose is reported. The brain, in which glucose utilization is essentially insensitive to plasma glucose and insulin concentrations, was used as an internal reference. The effects of graded doses of oral glucose loading (0.5, 1 and 2 mg/g body weight) on insulin-sensitive tissues (heart, muscle and fat tissue) were studied in the rat. By using the brain-reference method, dose-dependent increases in glucose utilization were clearly shown in all the insulin-sensitive tissues examined. The method seems to be of value for measurement of glucose utilization using radioactive deoxyglucose and positron emission tomography in the heart or other insulin-sensitive tissues, especially during glucose loading. (orig.)

  3. The relationships between common measures of glucose meter performance.

    Science.gov (United States)

    Wilmoth, Daniel R

    2012-09-01

    Glucose meter performance is commonly measured in several different ways, including the relative bias and coefficient of variation (CV), the total error, the mean absolute relative deviation (MARD), and the size of the interval around the reference value that would be necessary to contain a meter measurement at a specified probability. This fourth measure is commonly expressed as a proportion of the reference value and will be referred to as the necessary relative deviation. A deeper understanding of the relationships between these measures may aid health care providers, patients, and regulators in comparing meter performances when different measures are used. The relationships between common measures of glucose meter performance were derived mathematically. Equations are presented for calculating the total error, MARD, and necessary relative deviation using the reference value, relative bias, and CV when glucose meter measurements are normally distributed. When measurements are also unbiased, the CV, total error, MARD, and necessary relative deviation are linearly related and are therefore equivalent measures of meter performance. The relative bias and CV provide more information about meter performance than the other measures considered but may be difficult for some audiences to interpret. Reporting meter performance in multiple ways may facilitate the informed selection of blood glucose meters. © 2012 Diabetes Technology Society.

  4. A portable measuring system for a competitive binding glucose biosensor

    Science.gov (United States)

    Colvin, Lydia E.; Means, A. Kristen; Grunlan, Melissa A.; Coté, Gerard L.

    2018-02-01

    Central to minimizing the long- and short-term complications associated with diabetes is careful monitoring and maintenance of blood glucose at normal levels. Towards replacing conventionally used finger-prick glucose testing, indwelling continuous glucose monitors (CGMs) based on amperometric electrodes have been introduced to the market. Envisioned to lead to a CGM with an increased lifetime, we report herein a fluorescently-labeled competitive binding assay contained within a hydrogel membrane whose glucose response is measured via a novel portable system. The optical system design included a laser source, bifurcated fiber, laser filter and simple fiber coupled spectrometer to obtain the change in FRET pair ratio of the assay. Glucose response of the assay in free solution was measured using this system across the physiologic range (0-200 mg/dL). The FRET pair ratio signal was seen to increase with glucose and the standard error of calibration was 22.42 mg/dL with a MARD value of 14.85%. When the assay was contained within the hydrogel membrane's central cavity and similarly analyzed, the standard error increased but the assay maintained its reversibility.

  5. Correlation between the Plasma Insulin and Glucose Concentration in Normal Korean Adults

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jang Kyu; Sung, Ho Kyung; Kim, Jin Eui [Radiological Research Institute, Seoul (Korea, Republic of)

    1971-09-15

    The correlation between the plasma insulin, and glucose concentration was studied in healthy Korean adults consisting of 20 males and 22 females of 16 to 38 years of age. The blood samples of above subjects were obtained through cubital vein at arbitrary times during their usual working hours. Plasma insulin was assayed by means of double antibody system of radioimmunoassay technics, and blood glucose was determined by means of Van Slyke-Folch method. Results were as follows : 1. There were no differences in the blood sugar levels in relation to the plasma insulin concentration either by sex or age. 2. In the case, when the plasma insulin concentration was within 50 mmuU/ml, the correlation between the insulin, and glucose concentration existed, the ratio of which was expressed as; Plasma glucose concentration (mg/dl)=91.9 + 0.08 X Insulin concentration r=0.62. 3. Insulinogenic index was 12.4%, which was somewhat higher than other reports. 4. It is suggested that the correlation between plasma insulin and glucose concentration could be determined at arbitrary times instead of fasting times.

  6. Modelling the growth and ethanol production of Brettanomyces bruxellensis at different glucose concentrations.

    Science.gov (United States)

    Aguilar-Uscanga, M G; Garcia-Alvarado, Y; Gomez-Rodriguez, J; Phister, T; Delia, M L; Strehaiano, P

    2011-08-01

    To study the effect of glucose concentrations on the growth by Brettanomyces bruxellensis yeast strain in batch experiments and develop a mathematical model for kinetic behaviour analysis of yeast growing in batch culture. A Matlab algorithm was developed for the estimation of model parameters. Glucose fermentation by B. bruxellensis was studied by varying its concentration (5, 9.3, 13.8, 16.5, 17.6 and 21.4%). The increase in substrate concentration up to a certain limit was accompanied by an increase in ethanol and biomass production; at a substrate concentration of 50-138 g l(-1), the ethanol and biomass production were 24, 59 and 6.3, 11.4 g l(-1), respectively. However, an increase in glucose concentration to 165 g l(-1) led to a drastic decrease in product formation and substrate utilization. The model successfully simulated the batch kinetic observed in all cases. The confidence intervals were also estimated at each phase at a 0.95 probability level in a t-Student distribution for f degrees of freedom. The maximum ethanol and biomass yields were obtained with an initial glucose concentration of 138 g l(-1). These experiments illustrate the importance of using a mathematical model applied to kinetic behaviour on glucose concentration by B. bruxellensis. © 2011 The Authors. Letters in Applied Microbiology © 2011 The Society for Applied Microbiology.

  7. The effect of extremely high glucose concentrations on 21 routine chemistry and thyroid Abbott assays: interference study

    OpenAIRE

    ?uhadar, Serap; K?seo?lu, Mehmet; ?inpolat, Yasemin; Bu?dayc?, G?ler; Usta, Murat; Semerci, Tuna

    2016-01-01

    Abstract Introduction: Extremely high glucose concentrations have been shown to interfere with creatinine assays especially with Jaffe method in peritoneal dialysate. Because diabetes is the fastest growing chronic disease in the world, laboratories study with varying glucose concentrations. We investigated whether different levels of glucose spiked in serum interfere with 21 routine chemistry and thyroid assays at glucose concentrations between 17-51 mmol/L. Materials and methods: Base...

  8. Glycolysis-induced discordance between glucose metabolic rates measured with radiolabeled fluorodeoxyglucose and glucose

    International Nuclear Information System (INIS)

    Ackermann, R.F.; Lear, J.L.

    1989-01-01

    We have developed an autoradiographic method for estimating the oxidative and glycolytic components of local CMRglc (LCMRglc), using sequentially administered [ 18 F]fluorodeoxyglucose (FDG) and [ 14 C]-6-glucose (GLC). FDG-6-phosphate accumulation is proportional to the rate of glucose phosphorylation, which occurs before the divergence of glycolytic (GMg) and oxidative (GMo) glucose metabolism and is therefore related to total cerebral glucose metabolism GMt: GMg + GMo = GMt. With oxidative metabolism, the 14 C label of GLC is temporarily retained in Krebs cycle-related substrate pools. We hypothesize that with glycolytic metabolism, however, a significant fraction of the 14 C label is lost from the brain via lactate production and efflux from the brain. Thus, cerebral GLC metabolite concentration may be more closely related to GMo than to GMt. If true, the glycolytic metabolic rate will be related to the difference between FDG- and GLC-derived LCMRglc. Thus far, we have studied normal awake rats, rats with limbic activation induced by kainic acid (KA), and rats visually stimulated with 16-Hz flashes. In KA-treated rats, significant discordance between FDG and GLC accumulation, which we attribute to glycolysis, occurred only in activated limbic structures. In visually stimulated rats, significant discordance occurred only in the optic tectum

  9. Glucose metabolism in chronic diabetic foot ulcers measured in vivo using microdialysis

    DEFF Research Database (Denmark)

    Simonsen, L; Holstein, P; Larsen, K

    1998-01-01

    Ten subjects with diabetes mellitus and unilateral chronic foot ulcer were investigated. Local tissue concentrations of glucose and lactate were measured using the microdialysis method at a distance of 0.5-1 cm from the edge of the ulcer and in normal skin in the contralateral foot. Subcutaneous...

  10. Preliminary evaluation of optical glucose sensing in red cell concentrations using near-infrared diffuse-reflectance spectroscopy

    Science.gov (United States)

    Suzuki, Yusuke; Maruo, Katsuhiko; Zhang, Alice W.; Shimogaki, Kazushige; Ogawa, Hideto; Hirayama, Fumiya

    2012-01-01

    Bacterial contamination of blood products is one of the most frequent infectious complications of transfusion. Since glucose levels in blood supplies decrease as bacteria proliferate, it should be possible to detect the presence of bacterial contamination by measuring the glucose concentrations in the blood components. Hence this study is aimed to serve as a preliminary study for the nondestructive measurement of glucose level in transfusion blood. The glucose concentrations in red blood cell (RBC) samples were predicted using near-infrared diffuse-reflectance spectroscopy in the 1350 to 1850 nm wavelength region. Furthermore, the effects of donor, hematocrit level, and temperature variations among the RBC samples were observed. Results showed that the prediction performance of a dataset which contained samples that differed in all three parameters had a standard error of 29.3 mg/dL. Multiplicative scatter correction (MSC) preprocessing method was also found to be effective in minimizing the variations in scattering patterns created by various sample properties. The results suggest that the diffuse-reflectance spectroscopy may provide another avenue for the detection of bacterial contamination in red cell concentrations (RCC) products.

  11. Fermentation of solutions of glucose-protein concentrate in a cascade-multi-ray unit

    Energy Technology Data Exchange (ETDEWEB)

    Denshchikov, M T; Shashilova, V P

    1964-01-01

    Glucose-protein concentrate is a material obtained by the hydrolysis of corn, containing glucose 75 to 80, maltose, isomaltose, and other non-fermentable sugars 1.5 to 2, H/sub 2/O 15 to 17, mineral matter 1.9 to 1%, and N-containing materials 3.2 to 3.4 g/kg. In earlier fermentation trails with this material, after addition of H/sub 2/O, only 10 to 12% ethanol concentrations were obtained. With period addition of citric acid and replacement of the yeast at regular intervals, using a cascade-multitray unit, 12 to 13% concentrations of ethanol were obtained.

  12. Transcutaneous Measurement of Blood Analyte Concentration Using Raman Spectroscopy

    Science.gov (United States)

    Barman, Ishan; Singh, Gajendra P.; Dasari, Ramachandra R.; Feld, Michael S.

    2008-11-01

    Diabetes mellitus is a chronic disorder, affecting nearly 200 million people worldwide. Acute complications, such as hypoglycemia, cardiovascular disease and retinal damage, may occur if the disease is not adequately controlled. As diabetes has no known cure, tight control of glucose levels is critical for the prevention of such complications. Given the necessity for regular monitoring of blood glucose, development of non-invasive glucose detection devices is essential to improve the quality of life in diabetic patients. The commercially available glucose sensors measure the interstitial fluid glucose by electrochemical detection. However, these sensors have severe limitations, primarily related to their invasive nature and lack of stability. This necessitates the development of a truly non-invasive glucose detection technique. NIR Raman Spectroscopy, which combines the substantial penetration depth of NIR light with the excellent chemical specificity of Raman spectroscopy, provides an excellent tool to meet the challenges involved. Additionally, it enables simultaneous determination of multiple blood analytes. Our laboratory has pioneered the use of Raman spectroscopy for blood analytes' detection in biological media. The preliminary success of our non-invasive glucose measurements both in vitro (such as in serum and blood) and in vivo has provided the foundation for the development of feasible clinical systems. However, successful application of this technology still faces a few hurdles, highlighted by the problems of tissue luminescence and selection of appropriate reference concentration. In this article we explore possible avenues to overcome these challenges so that prospective prediction accuracy of blood analytes can be brought to clinically acceptable levels.

  13. Vasopressin activates Akt/mTOR pathway in smooth muscle cells cultured in high glucose concentration

    Energy Technology Data Exchange (ETDEWEB)

    Montes, Daniela K.; Brenet, Marianne; Muñoz, Vanessa C.; Burgos, Patricia V.; Villanueva, Carolina I. [Department of Physiology, Universidad Austral de Chile, Valdivia 509-9200 (Chile); Figueroa, Carlos D. [Department of Anatomy, Histology and Pathology, Universidad Austral de Chile, Valdivia 509-9200 (Chile); González, Carlos B., E-mail: cbgonzal@uach.cl [Department of Physiology, Universidad Austral de Chile, Valdivia 509-9200 (Chile); Department of Neuroscience and Cell Biology, University of Texas Medical Branch, Galveston, TX 77555 (United States)

    2013-11-29

    Highlights: •AVP induces mTOR phosphorylation in A-10 cells cultured in high glucose concentration. •The mTOR phosphorylation is mediated by the PI3K/Akt pathway activation. •The AVP-induced mTOR phosphorylation inhibited autophagy and stimulated cell proliferation. -- Abstract: Mammalian target of rapamycin (mTOR) complex is a key regulator of autophagy, cell growth and proliferation. Here, we studied the effects of arginine vasopressin (AVP) on mTOR activation in vascular smooth muscle cells cultured in high glucose concentration. AVP induced the mTOR phosphorylation in A-10 cells grown in high glucose, in contrast to cells cultured in normal glucose; wherein, only basal phosphorylation was observed. The AVP-induced mTOR phosphorylation was inhibited by a PI3K inhibitor. Moreover, the AVP-induced mTOR activation inhibited autophagy and increased thymidine incorporation in cells grown in high glucose. This increase was abolished by rapamycin which inhibits the mTORC1 complex formation. Our results suggest that AVP stimulates mTOR phosphorylation by activating the PI3K/Akt signaling pathway and, subsequently, inhibits autophagy and raises cell proliferation in A-10 cells maintained in high glucose concentration.

  14. Effect of the fructose and glucose concentration on the rheological ...

    African Journals Online (AJOL)

    Jose Luis Montañez Soto

    2013-03-20

    Mar 20, 2013 ... Key words: High fructose syrups, viscosity, rheological behavior, Newtonian fluids. ... shear rate; ºBrix, soluble solids %; K, consistency index; n, flow behavior index. ... the correlations between rheological measurements and.

  15. A Computer-Based Glucose Management System Reduces the Incidence of Forgotten Glucose Measurements: A Retrospective Observational Study.

    Science.gov (United States)

    Okura, Tsuyoshi; Teramoto, Kei; Koshitani, Rie; Fujioka, Yohei; Endo, Yusuke; Ueki, Masaru; Kato, Masahiko; Taniguchi, Shin-Ichi; Kondo, Hiroshi; Yamamoto, Kazuhiro

    2018-04-17

    Frequent glucose measurements are needed for good blood glucose control in hospitals; however, this requirement means that measurements can be forgotten. We developed a novel glucose management system using an iPod ® and electronic health records. A time schedule system for glucose measurement was developed using point-of-care testing, an iPod ® , and electronic health records. The system contains the glucose measurement schedule and an alarm sounds if a measurement is forgotten. The number of times measurements were forgotten was analyzed. Approximately 7000 glucose measurements were recorded per month. Before implementation of the system, the average number of times measurements were forgotten was 4.8 times per month. This significantly decreased to 2.6 times per month after the system started. We also analyzed the incidence of forgotten glucose measurements as a proportion of the total number of measurements for each period and found a significant difference between the two 9-month periods (43/64,049-24/65,870, P = 0.014, chi-squared test). This computer-based blood glucose monitoring system is useful for the management of glucose monitoring in hospitals. Johnson & Johnson Japan.

  16. Effect of radioactive isotope 32P upon alpha amylase activity and glucose concentration in chickens

    International Nuclear Information System (INIS)

    Kraljevic, P.; Emanovic, D.; Simpraga, M.; Nejedli, S.; Stojevic, Z.

    1996-01-01

    An attempt has been made to investigate whether alpha amylase activity and glucose concentration in blood plasma can serve as the help in establishing on early diagnosis of organic or functional damage caused by ionizing radiation in chickens. Fifty day old hybrid chickens of heavy 'Jata' breeds of both sexes, were treated by 32 P administered intramusculary as sodium orthophosphate in a single dose of 333 MBq per kilogram of body weight. Blood samples was taken from the wing vein on day 1, 3, 5, 7 and 10 after administration of 32 P. Alpha amylase activity and glucose concentration were determined spectrophotometrically using kits produced by 'Radonja', Sisak. Alpha amylase activity was decreased and glucose concentration was increased during investigated period. Yet, the further investigations are needed to find out whether these two parameters can be used for early diagnosis of injury in chicken organism by ionizing radiation. (author)

  17. An In-Line Photonic Biosensor for Monitoring of Glucose Concentrations

    Directory of Open Access Journals (Sweden)

    Ala'aldeen Al-Halhouli

    2014-08-01

    Full Text Available This paper presents two PDMS photonic biosensor designs that can be used for continuous monitoring of glucose concentrations. The first design, the internally immobilized sensor, consists of a reactor chamber, micro-lenses and self-alignment structures for fiber optics positioning. This sensor design allows optical detection of glucose concentrations under continuous glucose flow conditions of 33 µL/h based on internal co-immobilization of glucose oxidase (GOX and horseradish peroxidase (HRP on the internal PDMS surface of the reactor chamber. For this design, two co-immobilization methods, the simple adsorption and the covalent binding (PEG methods were tested. Experiments showed successful results when using the covalent binding (PEG method, where glucose concentrations up to 5 mM with a coefficient of determination (R2 of 0.99 and a limit of detection of 0.26 mM are detectable. The second design is a modified version of the internally immobilized sensor, where a microbead chamber and a beads filling channel are integrated into the sensor. This modification enabled external co-immobilization of enzymes covalently onto functionalized silica microbeads and allows binding a huge amount of HRP and GOX enzymes on the microbeads surfaces which increases the interaction area between immobilized enzymes and the analyte. This has a positive effect on the amount and rate of chemical reactions taking place inside the chamber. The sensor was tested under continuous glucose flow conditions and was found to be able to detect glucose concentrations up to 10 mM with R2 of 0.98 and a limit of detection of 0.7 mM. Such results are very promising for the application in photonic LOC systems used for online analysis.

  18. Differential Responses of Plasma Adropin Concentrations To Dietary Glucose or Fructose Consumption In Humans.

    Science.gov (United States)

    Butler, Andrew A; St-Onge, Marie-Pierre; Siebert, Emily A; Medici, Valentina; Stanhope, Kimber L; Havel, Peter J

    2015-10-05

    Adropin is a peptide hormone encoded by the Energy Homeostasis Associated (ENHO) gene whose physiological role in humans remains incompletely defined. Here we investigated the impact of dietary interventions that affect systemic glucose and lipid metabolism on plasma adropin concentrations in humans. Consumption of glucose or fructose as 25% of daily energy requirements (E) differentially affected plasma adropin concentrations (P Glucose consumption reduced plasma adropin from 3.55 ± 0.26 to 3.28 ± 0.23 ng/ml (N = 42). Fructose consumption increased plasma adropin from 3.63 ± 0.29 to 3.93 ± 0.34 ng/ml (N = 45). Consumption of high fructose corn syrup (HFCS) as 25% E had no effect (3.43 ± 0.32 versus 3.39 ± 0.24 ng/ml, N = 26). Overall, the effect of glucose, HFCS and fructose on circulating adropin concentrations were similar to those observed on postprandial plasma triglyceride concentrations. Furthermore, increases in plasma adropin levels with fructose intake were most robust in individuals exhibiting hypertriglyceridemia. Individuals with low plasma adropin concentrations also exhibited rapid increases in plasma levels following consumption of breakfasts supplemented with lipids. These are the first results linking plasma adropin levels with dietary sugar intake in humans, with the impact of fructose consumption linked to systemic triglyceride metabolism. In addition, dietary fat intake may also increase circulating adropin concentrations.

  19. The importance of different frequency bands in predicting subcutaneous glucose concentration in type 1 diabetic patients.

    Science.gov (United States)

    Lu, Yinghui; Gribok, Andrei V; Ward, W Kenneth; Reifman, Jaques

    2010-08-01

    We investigated the relative importance and predictive power of different frequency bands of subcutaneous glucose signals for the short-term (0-50 min) forecasting of glucose concentrations in type 1 diabetic patients with data-driven autoregressive (AR) models. The study data consisted of minute-by-minute glucose signals collected from nine deidentified patients over a five-day period using continuous glucose monitoring devices. AR models were developed using single and pairwise combinations of frequency bands of the glucose signal and compared with a reference model including all bands. The results suggest that: for open-loop applications, there is no need to explicitly represent exogenous inputs, such as meals and insulin intake, in AR models; models based on a single-frequency band, with periods between 60-120 min and 150-500 min, yield good predictive power (error bands produce predictions that are indistinguishable from those of the reference model as long as the 60-120 min period band is included; and AR models can be developed on signals of short length (approximately 300 min), i.e., ignoring long circadian rhythms, without any detriment in prediction accuracy. Together, these findings provide insights into efficient development of more effective and parsimonious data-driven models for short-term prediction of glucose concentrations in diabetic patients.

  20. [A non-invasive glucose measurement method based on orthogonal twin-polarized light and its pilot experimental investigation].

    Science.gov (United States)

    Wang, Hong; Wu, Baoming; Liu, Ding

    2010-04-01

    In order to overcome the existing shortcomings of the non-invasive blood glucose polarized light measurement methods of optical heterodyne detection and direct detection, we present in this paper a new orthogonal twin-polarized light (OTPL) non-invasive blood glucose measurement method, which converts the micro-angle rotated by an optical active substance such as glucose to the energy difference of OTPL, amplifies the signals by the high-sensitivity lock-in amplifier made of relevant principle, controls Faraday coil current to compensate the changes in deflection angle caused by blood glucose, and makes use of the linear relationship between blood glucose concentration and Faraday coil current to calculate blood glucose concentration. In our comparative experiment using the data measured by LX-20 automatic biochemical analyzer as a standard, a 0.9777 correlation coefficient is obtained in glucose concentration experiment, and a 0.952 in serum experiment. The result shows that this method has higher detection sensitivity and accuracy and lays a foundation for the development of practical new type of non-invasive blood glucose tester for diabetic patients.

  1. Effects of 1 and 3 g cinnamon on gastric emptying, satiety, and postprandial blood glucose, insulin, glucose-dependent insulinotropic polypeptide, glucagon-like peptide 1, and ghrelin concentrations in healthy subjects

    DEFF Research Database (Denmark)

    Hlebowicz, Joanna; Hlebowicz, Anna; Lindstedt, Sandra

    2009-01-01

    glucose, plasma concentrations of insulin and incretin hormones [glucose-dependent insulinotropic polypeptide (GIP) and glucagon-like peptide 1 (GLP-1)], the ghrelin response, and satiety in healthy subjects. DESIGN: GER was measured by using real-time ultrasonography after ingestion of rice pudding...... with and without 1 or 3 g cinnamon. Fifteen healthy subjects were assessed in a crossover trial. RESULTS: The addition of 1 or 3 g cinnamon had no significant effect on GER, satiety, glucose, GIP, or the ghrelin response. The insulin response at 60 min and the area under the curve (AUC) at 120 min were...... cinnamon (P = 0.0082 and P = 0.0138, respectively, after Bonferroni correction). CONCLUSIONS: Ingestion of 3 g cinnamon reduced postprandial serum insulin and increased GLP-1 concentrations without significantly affecting blood glucose, GIP, the ghrelin concentration, satiety, or GER in healthy subjects...

  2. Simultaneous measurement of glucose transport and utilization in the human brain

    OpenAIRE

    Shestov, Alexander A.; Emir, Uzay E.; Kumar, Anjali; Henry, Pierre-Gilles; Seaquist, Elizabeth R.; Öz, Gülin

    2011-01-01

    Glucose is the primary fuel for brain function, and determining the kinetics of cerebral glucose transport and utilization is critical for quantifying cerebral energy metabolism. The kinetic parameters of cerebral glucose transport, KMt and Vmaxt, in humans have so far been obtained by measuring steady-state brain glucose levels by proton (1H) NMR as a function of plasma glucose levels and fitting steady-state models to these data. Extraction of the kinetic parameters for cerebral glucose tra...

  3. Effect of abomasal glucose infusion on plasma concentrations of gut peptides in periparturient dairy cows

    DEFF Research Database (Denmark)

    Larsen, Mogens; Relling, A E; Reynolds, C K

    2010-01-01

    Six Holstein cows fitted with ruminal cannulas and permanent indwelling catheters in the portal vein, hepatic vein, mesenteric vein, and an artery were used to study the effects of abomasal glucose infusion on splanchnic plasma concentrations of gut peptides. The experimental design was a randomi...

  4. Myo-inositol, glucose and zinc concentrations determined in the preconceptional period, during and after pregnancy.

    NARCIS (Netherlands)

    Groenen, P.M.; Roes, E.M.; Peer, P.G.M.; Merkus, H.M.; Steegers, E.A.P.; Steegers-Theunissen, R.P.M.

    2006-01-01

    OBJECTIVE: To determine the blood concentrations of myo-inositol, glucose and zinc before, during and after normal pregnancy. STUDY DESIGN: Preconceptionally, at 6, 10, 20, 30 and 37 weeks amenorrhea, and 6 weeks after delivery, blood samples of 18 nulliparae and 19 multiparae were obtained and

  5. Measurement of glucose utilization by Pseudomonas fluorescens that are free-living and that are attached to surfaces

    International Nuclear Information System (INIS)

    Fletcher, M.

    1986-01-01

    The assimilation and respiration of glucose by attached and free-living Pseudomonas fluorescens were compared. The attachment surfaces were polyvinylidene fluoride, polyethylene, and glass. Specific uptake of [ 1 C]glucose was determined after bacterial biomass was measured by (1) microscopic counts or (2) prelabelling of cells by providing [ 3 H]leucine as substrate, followed by dual-labelling scintillation counting. The glucose concentration was 1.4, 3.5, 5.5, 7.6, or 9.7 μM. Glucose assimilation by cells which became detached from the surfaces during incubation with glucose was also measured after the detached cells were collected by filtration. The composition of the substratum had no effect on the amount of glucose assimilated by attached cells. Glucose assimilation by attached cells exceeded that by free-living cells by a factor of between 2 and 5 or more, and respiration of glucose by surface-associated cells was greater than that by free-living bacteria. Glucose assimilation by detached cells was greater than that by attached bacteria. Measurements of biomass by microscopic counts gave more consistent results than those obtained with dual-labelling, but in general, results obtained by both methods were corroborative

  6. Dietary patterns predict changes in two-hour post-oral glucose tolerance test plasma glucose concentrations in middle-aged adults.

    Science.gov (United States)

    Lau, Cathrine; Toft, Ulla; Tetens, Inge; Carstensen, Bendix; Jørgensen, Torben; Pedersen, Oluf; Borch-Johnsen, Knut

    2009-03-01

    We examined whether the adherence to major dietary patterns at baseline of 5824 nondiabetic Danes (30-60 y) enrolled in the nonpharmacological Inter99 intervention predicted changes in fasting plasma glucose (FPG) and postchallenge 2-h plasma glucose (2h-PG) concentrations during a 5 y period and whether a potential association was dependent on baseline glucose tolerance status. Through principal component analysis, a score for a traditional dietary pattern (characterized by higher intakes of high-fat sandwich spreads, red meat, potatoes, butter and lard, low-fat fish, sandwich meat, and sauces) and a score for a modern dietary pattern (characterized by higher intakes of vegetables, fruit, vegetable oil/vinegar dressing, poultry, pasta, rice, and cereals) were estimated for each person at baseline. Random effect models adjusting for relevant confounders were used to estimate changes in repetitive measures of FPG and 2h-PG. A higher modern score (of 1 SD) predicted an annual decrease in 2h-PG of 0.015 mmol/L (P dressing, poultry, pasta, rice, and cereals.

  7. Carbohydrate ingestion before and during soccer match play and blood glucose and lactate concentrations.

    Science.gov (United States)

    Russell, Mark; Benton, David; Kingsley, Michael

    2014-01-01

    The ingestion of carbohydrate (CHO) before and during exercise and at halftime is commonly recommended to soccer players for maintaining blood glucose concentrations throughout match play. However, an exercise-induced rebound glycemic response has been observed in the early stages of the second half of simulated soccer-specific exercise when CHO-electrolyte beverages were consumed regularly. Therefore, the metabolic effects of CHO beverage consumption throughout soccer match play remain unclear. To investigate the blood glucose and blood lactate responses to CHOs ingested before and during soccer match play. Crossover study. Applied research study. Ten male outfield academy soccer players (age = 15.6 ± 0.2 years, height = 1.74 ± 0.02 m, mass = 65.3 ± 1.9 kg, estimated maximal oxygen consumption = 58.4 ± 0.8 mL·kg(-1)·min(-1)). Players received a 6% CHO-electrolyte solution or an electrolyte (placebo) solution 2 hours before kickoff, before each half (within 10 minutes), and every 15 minutes throughout exercise. Blood samples were obtained at rest, every 15 minutes during the match (first half: 0-15, 15-30, and 30-45 minutes; second half: 45-60, 60-75, and 75-90 minutes) and 10 minutes into the halftime break. Metabolic responses (blood glucose and blood lactate concentrations) and markers of exercise intensity (heart rate) were recorded. Supplementation influenced the blood glucose response to exercise (time × treatment interaction effect: P ≤ .05), such that glucose concentrations were higher at 30 to 45 minutes in the CHO than in the placebo condition. However, in the second half, blood glucose concentrations were similar between conditions because of transient reductions from peak values occurring in both trials at halftime. Blood lactate concentrations were elevated above those at rest in the first 15 minutes of exercise (time-of-sample effect: P interaction effect: P = .49). Ingestion of a 6% CHO-electrolyte beverage before and during soccer match

  8. Recalculation of measured fuel nuclide concentrations

    International Nuclear Information System (INIS)

    Moeller, W.

    1984-01-01

    The concentrations and concentration ratios of heavy fuel nuclides determined in the Central Institute for Nuclear Research Rossendorf on the basis of destructive burnup measurements are compared with the results of microburnup calculations. The possibility is discussed to improve the results by taking into account the spectral characteristics at the positions of the measuring samples. (author)

  9. Benfotiamine increases glucose oxidation and downregulates NADPH oxidase 4 expression in cultured human myotubes exposed to both normal and high glucose concentrations.

    Science.gov (United States)

    Fraser, D A; Hessvik, N P; Nikolić, N; Aas, V; Hanssen, K F; Bøhn, S K; Thoresen, G H; Rustan, A C

    2012-07-01

    The aim of the present work was to study the effects of benfotiamine (S-benzoylthiamine O-monophosphate) on glucose and lipid metabolism and gene expression in differentiated human skeletal muscle cells (myotubes) incubated for 4 days under normal (5.5 mM glucose) and hyperglycemic (20 mM glucose) conditions. Myotubes established from lean, healthy volunteers were treated with benfotiamine for 4 days. Glucose and lipid metabolism were studied with labeled precursors. Gene expression was measured using real-time polymerase chain reaction (qPCR) and microarray technology. Benfotiamine significantly increased glucose oxidation under normoglycemic (35 and 49% increase at 100 and 200 μM benfotiamine, respectively) as well as hyperglycemic conditions (70% increase at 200 μM benfotiamine). Benfotiamine also increased glucose uptake. In comparison, thiamine (200 μM) increased overall glucose metabolism but did not change glucose oxidation. In contrast to glucose, mitochondrial lipid oxidation and overall lipid metabolism were unchanged by benfotiamine. The expression of NADPH oxidase 4 (NOX4) was significantly downregulated by benfotiamine treatment under both normo- and hyperglycemic conditions. Gene set enrichment analysis (GSEA) showed that befotiamine increased peroxisomal lipid oxidation and organelle (mitochondrial) membrane function. In conclusion, benfotiamine increases mitochondrial glucose oxidation in myotubes and downregulates NOX4 expression. These findings may be of relevance to type 2 diabetes where reversal of reduced glucose oxidation and mitochondrial capacity is a desirable goal.

  10. What Happens to Blood Glucose Concentrations After Oral Treatment for Neonatal Hypoglycemia?

    Science.gov (United States)

    Harris, Deborah L; Gamble, Greg D; Weston, Philip J; Harding, Jane E

    2017-11-01

    To determine the change in blood glucose concentration after oral treatment of infants with hypoglycemia in the first 48 hours after birth. We analyzed data from 227 infants with hypoglycemia (blood glucose dextrose or placebo gel plus feeding with formula, expressed breast milk, or breast feeding. The overall mean increase in blood glucose concentration was 11.7 mg/dL (95% CI 10.4-12.8). The increase was greater after buccal dextrose gel than after placebo gel (+3.0 mg/dL; 95% CI 0.7-5.3; P = .01) and greater after infant formula than after other feedings (+3.8 mg/dL; 95% CI 0.8-6.7; P = .01). The increase in blood glucose concentration was not affected by breast feeding (+2.0 mg/dL; 95% CI -0.3 to 44.2; P = .09) or expressed breast milk (-1.4 mg/dL; 95% CI -3.7 to 0.9; P = .25). However, breast feeding was associated with reduced requirement for repeat gel treatment (OR = 0.52; 95% CI 0.28-0.94; P = .03). Treatment of infants with hypoglycemia with dextrose gel or formula is associated with increased blood glucose concentration and breast feeding with reduced need for further treatment. Dextrose gel and breast feeding should be considered for first-line oral treatment of infants with hypoglycemia. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Glucose concentration and blood acid-basis status in high-yielding dairy cows during heat stress

    Directory of Open Access Journals (Sweden)

    Vujanac Ivan

    2011-01-01

    Full Text Available The objective of this work was to examine the effect of heat stress on glucose and pH values in blood of high-yielding dairy cows in the early stage of lactation, as well as to determine whether the changes in these parameters are interdependent under such conditions. An experiment was performed on high-yielding dairy cows during the summer and the spring periods. Forty cows were selected, twenty each for the two periods under investigation. In the course of the experiment, the temperature humidity index (THI was determined for the entire period of investigations, and then also the average daily THI, nightmorning THI (average value of hourly THI measured from 22h on the previous day until 10h of the current day, as well as the day-night THI (average value of hourly THI measured during the period from 10h to 22h of the current day. The pH and glucose concentration were determined in blood samples taken in the morning and afternoon of days 30, 60, and 90 of lactation during the spring and summer periods of the investigations. Based on the results for the THI, it was established that the animals were not exposed to the effect of extreme heat stress during the spring period of investigations, while they were periodically exposed to moderate but also extreme heat stress during the summer, in particular in the afternoon hours. It can be concluded from the results obtained for the blood pH that the cows were in respiratory alkalosis during the summer in the morning and afternoon hours on day 30, in the afternoon hours of days 60 and 90 of lactation, as well as in the afternoon on day 90 of lactation during the spring period of investigations. During the summer period, there were no statistically significant differences between the pH value determined in the morning and afternoon hours on day 30 of lactation, while the pH value was significantly higher in the afternoon hours than in the morning hours on days 60 and 90 of lactation. There were no

  12. Noninvasive measurement of blood glucose level using mid-infrared quantum cascade lasers

    Science.gov (United States)

    Yoshioka, Kiriko; Kino, Saiko; Matsuura, Yuji

    2017-04-01

    For non-invasive measurement of blood glucose level, attenuated total reflection (ATR) absorption spectroscopy system using a QCL as a light source was developed. The results of measurement of glucose solutions showed that the system had a sensitivity that was enough for blood glucose measurement. In-vivo measurement using the proposed system based on QCL showed that there was a correlation between absorptions measured with human lips and blood glucose level.

  13. The fluctuation of blood glucose, insulin and glucagon concentrations before and after insulin therapy in type 1 diabetes

    Science.gov (United States)

    Arif, Idam; Nasir, Zulfa

    2015-09-01

    A dynamical-systems model of plasma glucose, insulin and glucagon concentrations has been developed to investigate the effects of insulin therapy on blood glucose, insulin and glucagon regulations in type 1 diabetic patients. Simulation results show that the normal regulation of blood glucose concentration depends on insulin and glucagon concentrations. On type 1 diabetic case, the role of insulin on regulating blood glucose is not optimal because of the destruction of β cells in pancreas. These β cells destructions cause hyperglycemic episode affecting the whole body metabolism. To get over this, type 1 diabetic patients need insulin therapy to control the blood glucose level. This research has been done by using rapid acting insulin (lispro), long-acting insulin (glargine) and the combination between them to know the effects of insulin therapy on blood glucose, insulin and glucagon concentrations. Simulation results show that these different types of insulin have different effects on blood glucose concentration. Insulin therapy using lispro shows better blood glucose control after consumption of meals. Glargin gives better blood glucose control between meals and during sleep. Combination between lispro and glargine shows better glycemic control for whole day blood glucose level.

  14. Glucose ameliorates the metabolic profile and mitochondrial function of platelet concentrates during storage in autologous plasma

    Science.gov (United States)

    Amorini, Angela M.; Tuttobene, Michele; Tomasello, Flora M.; Biazzo, Filomena; Gullotta, Stefano; De Pinto, Vito; Lazzarino, Giuseppe; Tavazzi, Barbara

    2013-01-01

    Background It is essential that the quality of platelet metabolism and function remains high during storage in order to ensure the clinical effectiveness of a platelet transfusion. New storage conditions and additives are constantly evaluated in order to achieve this. Using glucose as a substrate is controversial because of its potential connection with increased lactate production and decreased pH, both parameters triggering the platelet lesion during storage. Materials and methods In this study, we analysed the morphological status and metabolic profile of platelets stored for various periods in autologous plasma enriched with increasing glucose concentrations (13.75, 27.5 and 55 mM). After 0, 2, 4, 6 and 8 days, high energy phosphates (ATP, GTP, ADP, AMP), oxypurines (hypoxanthine, xanthine, uric acid), lactate, pH, mitochondrial function, cell lysis and morphology, were evaluated. Results The data showed a significant dose-dependent improvement of the different parameters in platelets stored with increasing glucose, compared to what detected in controls. Interestingly, this phenomenon was more marked at the highest level of glucose tested and in the period of time generally used for platelet transfusion (0–6 days). Conclusion These results indicate that the addition of glucose during platelet storage ameliorates, in a dose-dependent manner, the biochemical parameters related to energy metabolism and mitochondrial function. Since there was no correspondence between glucose addition, lactate increase and pH decrease in our experiments, it is conceivable that platelet derangement during storage is not directly caused by glucose through an increase of anaerobic glycolysis, but rather to a loss of mitochondrial functions caused by reduced substrate availability. PMID:22682337

  15. Determination of NIR informative wavebands for transmission non-invasive blood glucose measurement using a Fourier transform spectrometer

    Science.gov (United States)

    Yang, Wenming; Liao, Ningfang; Cheng, Haobo; Li, Yasheng; Bai, Xueqiong; Deng, Chengyang

    2018-03-01

    Non-invasive blood glucose measurement using near infrared (NIR) spectroscopy relies on wavebands that provide reliable information about spectral absorption. In this study, we investigated wavebands which are informative for blood glucose in the NIR shortwave band (900˜1450 nm) and the first overtone band (1450˜1700 nm) through a specially designed NIR Fourier transform spectrometer (FTS), which featured a test fixture (where a sample or subject's finger could be placed) and all-reflective optics, except for a Michelson structure. Different concentrations of glucose solution and seven volunteers who had undergone oral glucose tolerance tests (OGTT) were studied to acquire transmission spectra in the shortwave band and the first overtone band. Characteristic peaks of glucose absorption were identified from the spectra of glucose aqueous solution by second-order derivative processing. The wavebands linked to blood glucose were successfully estimated through spectra of the middle fingertip of OGTT participants by a simple linear regression and correlation coefficient. The light intensity difference showed that glucose absorption in the first overtone band was much more prominent than it was in the shortwave band. The results of the SLR model established from seven OGTTs in total on seven participants enabled a positive estimation of the glucose-linked wavelength. It is suggested that wavebands with prominent characteristic peaks, a high correlation coefficient between blood glucose and light intensity difference and a relatively low standard deviation of predicted values will be the most informative wavebands for transmission non-invasive blood glucose measurement methods. This work provides a guidance for waveband selection for the development of non-invasive NIR blood glucose measurement.

  16. Glucose concentration in capillary blood of dairy cows obtained by a minimally invasive lancet technique and determined with three different hand-held devices

    OpenAIRE

    Mair, B.; Drillich, M.; Klein-J?bstl, D.; Kanz, P.; Borchardt, S.; Meyer, L.; Schwendenwein, I.; Iwersen, M.

    2016-01-01

    Background Dairy cows have a massive demand for glucose at the onset of lactation. A poor adaption to this period leads to an excessive negative energy balance with an increased risk for ketosis and impaired animal health and production. Besides the measurement of ketones, analysing the glucose concentration in blood is reported as helpful instrument for diagnosis and differentiation of ketosis. Monitoring metabolic parameters requires multiple blood sampling. In other species, new blood samp...

  17. The Unscented Kalman Filter estimates the plasma insulin from glucose measurement.

    Science.gov (United States)

    Eberle, Claudia; Ament, Christoph

    2011-01-01

    Understanding the simultaneous interaction within the glucose and insulin homeostasis in real-time is very important for clinical treatment as well as for research issues. Until now only plasma glucose concentrations can be measured in real-time. To support a secure, effective and rapid treatment e.g. of diabetes a real-time estimation of plasma insulin would be of great value. A novel approach using an Unscented Kalman Filter that provides an estimate of the current plasma insulin concentration is presented, which operates on the measurement of the plasma glucose and Bergman's Minimal Model of the glucose insulin homeostasis. We can prove that process observability is obtained in this case. Hence, a successful estimator design is possible. Since the process is nonlinear we have to consider estimates that are not normally distributed. The symmetric Unscented Kalman Filter (UKF) will perform best compared to other estimator approaches as the Extended Kalman Filter (EKF), the simplex Unscented Kalman Filter (UKF), and the Particle Filter (PF). The symmetric UKF algorithm is applied to the plasma insulin estimation. It shows better results compared to the direct (open loop) estimation that uses a model of the insulin subsystem. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  18. Comparison of two methods using plasma triglyceride concentration as a surrogate estimate of insulin action in nondiabetic subjects: triglycerides × glucose versus triglyceride/high-density lipoprotein cholesterol.

    Science.gov (United States)

    Abbasi, Fahim; Reaven, Gerald M

    2011-12-01

    The objective was to compare relationships between insulin-mediated glucose uptake and surrogate estimates of insulin action, particularly those using fasting triglyceride (TG) and high-density lipoprotein cholesterol (HDL-C) concentrations. Insulin-mediated glucose uptake was quantified by determining the steady-state plasma glucose (SSPG) concentration during the insulin suppression test in 455 nondiabetic subjects. Fasting TG, HDL-C, glucose, and insulin concentrations were measured; and calculations were made of the following: (1) plasma concentration ratio of TG/HDL-C, (2) TG × fasting glucose (TyG index), (3) homeostasis model assessment of insulin resistance, and (4) insulin area under the curve (insulin-AUC) during a glucose tolerance test. Insulin-AUC correlated most closely with SSPG (r ∼ 0.75, P index, homeostasis model assessment of insulin resistance, and fasting TG and insulin (r ∼ 0.60, P index correlated with SSPG concentration to a similar degree, and the relationships were comparable to estimates using fasting insulin. The strongest relationship was between SSPG and insulin-AUC. Copyright © 2011 Elsevier Inc. All rights reserved.

  19. Continuous measurements of outdoor radon concentrations

    International Nuclear Information System (INIS)

    Iida, T.; Ikebe, Y.; Suzuki, K.; Ueno, K.; Komura, K.; Kato, I.; Jin Yihe

    1993-01-01

    The authors studied and developed an electrostatic 222 Rn monitor and have measured continuously outdoor radon ( 222 Rn) concentrations at Nagoya University since 1985. Four 222 Rn monitors were newly constructed to measure outdoor 222 Rn concentrations at other locations. The 222 Rn concentrations at Nagoya and Kasugai show a clear diurnal variation in autumn, and a seasonal pattern of a spring-summer minimum and a autumn-winter maximum. The results at Toki are the same pattern as that at Nagoya except spring. The concentrations at Kanazawa show a slight seasonal variation. A clear diurnal variation is observed in summer. (4 figs.)

  20. Electrocatalytic glucose sensor

    Energy Technology Data Exchange (ETDEWEB)

    Gebhardt, U; Luft, G; Mund, K; Preidel, W; Richter, G J

    1983-01-01

    An artificial pancreas consists of an insulin depot, a dosage unit and a glucose sensor. The measurement of the actual glucose concentration in blood is still an unsolved problem. Two methods are described for an electrocatalytic glucose sensor. Under the interfering action of amino acids and urea in-vitro measurements show an error of between 10% and 20%.

  1. Comparative study of the concentration of salivary and blood glucose in type 2 diabetic patients.

    Science.gov (United States)

    Vasconcelos, Ana Carolina U; Soares, Maria Sueli M; Almeida, Paulo C; Soares, Teresa C

    2010-06-01

    The objective of the present study was to comparatively evaluate the concentrations of blood and salivary glucose as well as salivary flow and xerostomia in type 2 diabetic and non-diabetic patients. The mean salivary glucose level in diabetic patients was 14.03 +/-16.76 mg/dl and 6.35 +/- 6.02 mg/dl (P = 0.036) in the control group. The mean capillary blood glucose level in diabetic patients was 213 +/- 88 mg/dl, while that in non-diabetic patients was 99 +/- 14 mg/dl (P = 0.000). The mean value for resting salivary flow was 0.21 +/- 0.16 ml/min in diabetic patients and 0.33 +/- 0.20 ml/min in the control group (P = 0.002). The stimulated salivary flow was lower in the group of diabetic patients, with a mean of 0.63 +/- 0.43 ml/min, whereas the control group showed a mean of 1.20 +/- 0.70 ml/min (P = 0.000). Of the diabetic patients, 45% exhibited hyposalivation, in contrast to 2.5% of the non-diabetic patients (P = 0.000). Xerostomia was reported in 12.5% of diabetic patients and 5% of non-diabetic patients (P = 0.23). We can conclude that salivary glucose concentration was significantly higher in the experimental group and that there was no correlation between salivary and blood glucose concentrations in diabetic patients. The total salivary flow was significantly reduced in diabetic patients and there was no significant difference as to the presence of xerostomia in both groups.

  2. Determination of Blood Glucose Concentration by Using Wavelet Transform and Neural Networks

    Directory of Open Access Journals (Sweden)

    Vajravelu Ashok

    2013-03-01

    Full Text Available Background: Early and non-invasive determination of blood glucose level is of great importance. We aimed to present a new technique to accurately infer the blood glucose concentration in peripheral blood flow using non-invasive optical monitoring system.Methods: The data for the research were obtained from 900 individuals. Of them, 750 people had diabetes mellitus (DM. The system was designed using a helium neon laser source of 632.8 nm wavelength with 5mW power, photo detectors and digital storage oscilloscope. The laser beam was directed through a single optical fiber to the index finger and the scattered beams were collected by the photo detectors placed circumferentially to the transmitting fiber. The received signals were filtered using band pass filter and finally sent to a digital storage oscilloscope. These signals were then decomposed into approximation and detail coefficients using modified Haar Wavelet Transform. Back propagation neural and radial basis functions were employed for the prediction of blood glucose concentration.Results: The data of 450 patients were randomly used for training, 225 for testing and the rest for validation. The data showed that outputs from radial basis function were nearer to the clinical value. Significant variations could be seen from signals obtained from patients with DM and those without DM.Conclusion: The proposed non-invasive optical glucose monitoring system is able to predict the glucose concentration by proving that there is a definite variation in hematological distribution between patients with DM and those without DM.

  3. The Influence of Variation in Time and HCl Concentration to the Glucose Produced from Kepok Banana

    Science.gov (United States)

    Widodo M, Rohman; Noviyanto, Denny; RM, Faisal

    2016-01-01

    Kepok banana (Musa paradisiaca) is a plant that has many advantagesfrom its fruit, stems, leaves, flowers and cob. However, we just tend to take benefit from the fruit. We grow and harvest the fruit without taking advantages from other parts. So they would be a waste or detrimental to animal nest if not used. The idea to take the benefit from the banana crop yields, especially cob is rarely explored. This study is an introduction to the use of banana weevil especially from the glucose it contains. This study uses current methods of hydrolysis using HCl as a catalyst with the concentration variation of 0.4 N, 0.6 N and 0.8 N and hydrolysis times variation of 20 minutes, 25 minutes and 30 minutes. The stages in the hydrolysis include preparation of materials, the process of hydrolysis and analysis of test results using Fehling and titrate with standard glucose solution. HCl is used as a catalyst because it is cheaper than the enzyme that has the same function. NaOH 60% is used for neutralizing the pH of the filtrate result of hydrolysis. From the results of analysis, known thatthe biggest yield of glucose is at concentration 0.8 N and at 30 minutes reaction, it contains 6.25 gram glucose / 20 gram dry sampel, and the convertion is 27.22% at 20 gram dry sampel.

  4. Alteration of postprandial glucose and insulin concentrations with meal frequency and composition.

    Science.gov (United States)

    Kanaley, Jill A; Heden, Timothy D; Liu, Ying; Fairchild, Timothy J

    2014-11-14

    A frequent eating pattern may alter glycaemic control and augment postprandial insulin concentrations in some individuals due to the truncation of the previous postprandial period by a subsequent meal. The present study examined glucose, insulin, C-peptide and glucose-dependent insulinotropic peptide (GIP) responses in obese individuals when meals were ingested in a high-frequency pattern (every 2 h, 6M) or in a low-frequency pattern (every 4 h, 3M) over 12 h. It also examined these postprandial responses to high-frequency, high-protein meals (6MHP). In total, thirteen obese subjects completed three 12 h study days during which they consumed 6276 kJ (1500 kcal): (1) 3M - 15 % protein and 65 % carbohydrate; (2) 6M - 15 % protein and 65 % carbohydrate; (3) 6MHP - 45 % protein and 35 % carbohydrate. Blood samples were collected every 10 min and analysed for glucose, insulin, C-peptide and GIP. Insulin total AUC (tAUC) and peak insulin concentrations (Pmeal frequency or composition. In obese subjects, ingestion of meals in a low-frequency pattern does not alter glucose tAUC, but increases postprandial insulin responses. The substitution of carbohydrates with protein in a frequent meal pattern results in tighter glycaemic control and reduced postprandial insulin responses.

  5. The effect of single low-dose dexamethasone on blood glucose concentrations in the perioperative period: a randomized, placebo-controlled investigation in gynecologic surgical patients.

    Science.gov (United States)

    Murphy, Glenn S; Szokol, Joseph W; Avram, Michael J; Greenberg, Steven B; Shear, Torin; Vender, Jeffery S; Gray, Jayla; Landry, Elizabeth

    2014-06-01

    The effect of single low-dose dexamethasone therapy on perioperative blood glucose concentrations has not been well characterized. In this investigation, we examined the effect of 2 commonly used doses of dexamethasone (4 and 8 mg at induction of anesthesia) on blood glucose concentrations during the first 24 hours after administration. Two hundred women patients were randomized to 1 of 6 groups: Early-control (saline); Early-4 mg (4 mg dexamethasone); Early-8 mg (8 mg dexamethasone); Late-control (saline); Late-4 mg (4 mg dexamethasone); and Late-8 mg (8 mg dexamethasone). Blood glucose concentrations were measured at baseline and 1, 2, 3, and 4 hours after administration in the early groups and at baseline and 8 and 24 hours after administration in the late groups. The incidence of hyperglycemic events (the number of patients with at least 1 blood glucose concentration >180 mg/dL) was determined. Blood glucose concentrations increased significantly over time in all control and dexamethasone groups (from median baselines of 94 to 102 mg/dL to maximum medians ranging from 141 to 161.5 mg/dL, all P < 0.001). Blood glucose concentrations did not differ significantly between the groups receiving dexamethasone (either 4 or 8 mg) and those receiving saline at any measurement time. The incidence of hyperglycemic events did not differ in any of the early (21%-28%, P = 0.807) or late (13%-24%, P = 0.552) groups. Because blood glucose concentrations during the first 24 hours after administration of single low-dose dexamethasone did not differ from those observed after saline administrations, these results suggest clinicians need not avoid using dexamethasone for nausea and vomiting prophylaxis out of concerns related to hyperglycemia.

  6. Sepsis does not alter red blood cell glucose metabolism or Na+ concentration: A 2H-, 23Na-NMR study

    International Nuclear Information System (INIS)

    Hotchkiss, R.S.; Song, S.K.; Ling, C.S.; Ackerman, J.J.; Karl, I.E.

    1990-01-01

    The effects of sepsis on intracellular Na+ concentration ([Na+]i) and glucose metabolism were examined in rat red blood cells (RBCs) by using 23Na- and 2H-nuclear magnetic resonance (NMR) spectroscopy. Sepsis was induced in 15 halothane-anesthetized female Sprague-Dawley rats by using the cecal ligation and perforation technique; 14 control rats underwent cecal manipulation without ligation. The animals were fasted for 36 h, but allowed free access to water. At 36 h postsurgery, RBCs were examined by 23Na-NMR by using dysprosium tripolyphosphate as a chemical shift reagent. Human RBCs from 17 critically ill nonseptic patients and from 7 patients who were diagnosed as septic were also examined for [Na+]i. Five rat RBC specimens had [Na+]i determined by both 23Na-NMR and inductively coupled plasma-atomic emission spectroscopy (ICP-AES). For glucose metabolism studies, RBCs from septic and control rats were suspended in modified Krebs-Henseleit buffer containing [6,6-2H2]glucose and examined by 2H-NMR. No significant differences in [Na+]i or glucose utilization were found in RBCs from control or septic rats. There were no differences in [Na+]i in the two groups of patients. The [Na+]i determined by NMR spectroscopy agreed closely with measurements using ICP-AES and establish that 100% of the [Na+]i of the RBC is visible by NMR. Glucose measurements determined by 2H-NMR correlated closely (correlation coefficient = 0.93) with enzymatic analysis. These studies showed no evidence that sepsis disturbed RBC membrane function or metabolism

  7. Serum proatrial natriuretic peptide concentrations during oral glucose-induced acute hyperinsulinemia in lean and obese men

    DEFF Research Database (Denmark)

    Asferg, Camilla L; Nielsen, Søren J; Andersen, Ulrik B

    2018-01-01

    Atrial natriuretic peptide (ANP) is primarily seen as a hormone involved in salt and water homeostasis and blood pressure regulation. Evidence supports a link between metabolism and ANP. Circulating ANP concentrations are low in obese individuals with insulin resistance and hyperinsulinemia....... The dynamic relationship between insulin and ANP has been sparsely studied. We therefore measured circulating concentrations of midregional proatrial natriuretic peptide (MR-proANP), a stable marker of ANP secretion, and insulin in lean and obese men during an oral glucose challenge. One hundred and three...... obese men (body mass index (BMI) ≥30.0 kg/m2) were compared with 27 lean men (BMI = 20.0-24.9 kg/m2). During a 75 g oral glucose challenge, circulating concentrations of MR-proANP and insulin were measured at baseline and every half hour for 2 h. Fasting MR-proANP concentrations were lower in the obese...

  8. Pre-analytical variation in glucose concentration due to atmospheric temperature and clot in blood specimens

    International Nuclear Information System (INIS)

    Butt, T.; Masud, K.; Khan, J.A.; Bhatti, M.S.

    2016-01-01

    Objective: To determine the effect of temperature and contact of clot with serum on laboratory results of glucose concentration in blood. Study Design: Quasi-experimental study. Place and Duration of Study: December 2014 to August 2015 at the laboratory of Shoaib Hospital, Fateh Jang, Attock Pakistan. Material and Methods: Samples were collected for estimation of blood glucose (Random) concentration from patients reporting to the hospital. Blood specimens (n=94) of such volunteers were analyzed for glucose level. Each sample was put up in five tubes. When the blood clotted the serum from tube-1 was analyzed for glucose level within 30 minutes. In tube-2 and tube-3 serum was kept for 24 hours at room temperature and refrigerator temperature respectively before glucose estimation. In tube-4 and tube-5 serum was not separated from clot and kept at room temperature and refrigerator temperature respectively before glucose estimation. The value of tube 1 was taken as reference value for comparison with other parts of the specimen. The equipment used for blood glucose level estimation was semi auto chemistry analyzer (Rayto, China). The kit used for analysis was Glucose - Liquizyme (Germany). Results: The difference between the mean reference value (tube-1) and refrigerated serum without clot (tube-3) was 4.63 mg/100 ml while that of unrefrigerated portion (tube-2) had a difference of 10.68 mg/100 ml. The mean of unrefrigerated (tube-4) and refrigerated (tube-5) portions of serum kept with the clot had difference of 42.05 mg/100 ml and 25.84 mg/100 ml respectively. The fall in the blood glucose level in all (n=94) the samples in the tube number 3 (serum separated and kept at refrigerated temperature) was 4.63 mg/100 ml +- 3.68 (Mean +- SD) and it ranged from 0 to 20 mg/100 ml whereas fall was maximum in the tube number 4 (serum with clotted blood and kept at room temperature) was 42.04 mg/100 ml +- 10.61 (Mean +- SD) and it ranged from 13 to 82 mg/100 ml. The sample in

  9. AMPK is involved in the regulation of incretin receptors expression in pancreatic islets under a low glucose concentration.

    Directory of Open Access Journals (Sweden)

    Kazuki Tajima

    Full Text Available The precise role of AMP-activated protein kinase (AMPK, a target of metformin, in pancreatic β cells remains controversial, even though metformin was recently shown to enhance the expression of incretin receptors (GLP-1 and GIP receptors in pancreatic β cells. In this study, we investigated the effect of AMPK in the regulation of incretin receptors expression in pancreatic islets. The phosphorylation of AMPK in the mouse islets was decreased by increasing glucose concentrations. We showed the expression of incretin receptors in bell-shaped response to glucose. Expression of the incretin receptors in the isolated islets showed higher levels under a medium glucose concentration (11.1 mM than that under a low glucose concentration (2.8 mM, but was suppressed under a high glucose concentration (22.2 mM. Both treatment with an AMPK inhibitor and DN-AMPK expression produced a significant increase of the incretin receptors expression under a low glucose concentration. By contrast, in hyperglycemic db/db islets, the enhancing effect of the AMPK inhibitor on the expression of incretin receptors was diminished under a low glucose concentration. Taken together, AMPK is involved in the regulation of incretin receptors expression in pancreatic islets under a low glucose concentration.

  10. Diabetes mellitus, fasting blood glucose concentration, and risk of vascular disease

    DEFF Research Database (Denmark)

    Sarwar, N; Gao, P; Seshasai, S R Kondapally

    2010-01-01

    BACKGROUND: Uncertainties persist about the magnitude of associations of diabetes mellitus and fasting glucose concentration with risk of coronary heart disease and major stroke subtypes. We aimed to quantify these associations for a wide range of circumstances. METHODS: We undertook a meta-analysis...... of individual records of diabetes, fasting blood glucose concentration, and other risk factors in people without initial vascular disease from studies in the Emerging Risk Factors Collaboration. We combined within-study regressions that were adjusted for age, sex, smoking, systolic blood pressure, and body......-mass index to calculate hazard ratios (HRs) for vascular disease. FINDINGS: Analyses included data for 698 782 people (52 765 non-fatal or fatal vascular outcomes; 8.49 million person-years at risk) from 102 prospective studies. Adjusted HRs with diabetes were: 2.00 (95% CI 1.83-2.19) for coronary heart...

  11. Blood Glucose and Insulin Concentrations after Octreotide Administration in Horses With Insulin Dysregulation

    OpenAIRE

    Frank, N.; Hermida, P.; Sanchez?Londo?o, A.; Singh, R.; Gradil, C.M.; Uricchio, C.K.

    2017-01-01

    Background Octreotide is a somatostatin analog that suppresses insulin secretion. Hypothesis We hypothesized that octreotide would suppress insulin concentrations in horses and that normal (N) horses and those with insulin dysregulation (ID) would differ significantly in their plasma glucose and insulin responses to administration of octreotide. Animals Twelve horses, N = 5, ID = 7. Methods Prospective study. An oral sugar test was performed to assign horses to N and ID groups. Octreotide (1....

  12. Visfatin and retinol-binding protein 4 concentrations in lean, glucose-tolerant women with PCOS.

    Science.gov (United States)

    Yildiz, Bulent O; Bozdag, Gurkan; Otegen, Umit; Harmanci, Ayla; Boynukalin, Kubra; Vural, Zehra; Kirazli, Serafettin; Yarali, Hakan

    2010-01-01

    Since insulin resistance is accepted to be a common feature of polycystic ovary syndrome (PCOS), the exact molecular mechanism(s) involved in glucose and lipid metabolism have been under investigation in the syndrome. Recently, two novel adipokines, namely visfatin and retinol-binding protein 4 (RBP4), have been suggested to play a role in insulin resistance and diabetes. This study sought to determine whether plasma concentrations of visfatin and RBP4 are altered in PCOS by comparing a total of 27 lean, normal glucose-tolerant PCOS patients with 19 age- and body mass index-matched healthy controls. The mean plasma visfatin concentrations were higher in PCOS patients than those in healthy subjects (37.9+/-18.2 versus 19.8+/-17.5, PPCOS (r=0.52, Plean, glucose-tolerant women with PCOS have increased circulating visfatin and unaltered RBP4 concentrations compared with healthy lean women. In order to clarify overlapping effects and their potential contribution to the pathophysiology of PCOS, further studies are needed. Copyright (c) 2009 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.

  13. Concentration and limit behaviors of stationary measures

    Science.gov (United States)

    Huang, Wen; Ji, Min; Liu, Zhenxin; Yi, Yingfei

    2018-04-01

    In this paper, we study limit behaviors of stationary measures of the Fokker-Planck equations associated with a system of ordinary differential equations perturbed by a class of multiplicative noise including additive white noise case. As the noises are vanishing, various results on the invariance and concentration of the limit measures are obtained. In particular, we show that if the noise perturbed systems admit a uniform Lyapunov function, then the stationary measures form a relatively sequentially compact set whose weak∗-limits are invariant measures of the unperturbed system concentrated on its global attractor. In the case that the global attractor contains a strong local attractor, we further show that there exists a family of admissible multiplicative noises with respect to which all limit measures are actually concentrated on the local attractor; and on the contrary, in the presence of a strong local repeller in the global attractor, there exists a family of admissible multiplicative noises with respect to which no limit measure can be concentrated on the local repeller. Moreover, we show that if there is a strongly repelling equilibrium in the global attractor, then limit measures with respect to typical families of multiplicative noises are always concentrated away from the equilibrium. As applications of these results, an example of stochastic Hopf bifurcation and an example with non-decomposable ω-limit sets are provided. Our study is closely related to the problem of noise stability of compact invariant sets and invariant measures of the unperturbed system.

  14. Blood gas sample spiking with total parenteral nutrition, lipid emulsion, and concentrated dextrose solutions as a model for predicting sample contamination based on glucose result.

    Science.gov (United States)

    Jara-Aguirre, Jose C; Smeets, Steven W; Wockenfus, Amy M; Karon, Brad S

    2018-05-01

    Evaluate the effects of blood gas sample contamination with total parenteral nutrition (TPN)/lipid emulsion and dextrose 50% (D50) solutions on blood gas and electrolyte measurement; and determine whether glucose concentration can predict blood gas sample contamination with TPN/lipid emulsion or D50. Residual lithium heparin arterial blood gas samples were spiked with TPN/lipid emulsion (0 to 15%) and D50 solutions (0 to 2.5%). Blood gas (pH, pCO2, pO2), electrolytes (Na+, K+ ionized calcium) and hemoglobin were measured with a Radiometer ABL90. Glucose concentration was measured in separated plasma by Roche Cobas c501. Chart review of neonatal blood gas results with glucose >300 mg/dL (>16.65 mmol/L) over a seven month period was performed to determine whether repeat (within 4 h) blood gas results suggested pre-analytical errors in blood gas results. Results were used to determine whether a glucose threshold could predict contamination resulting in blood gas and electrolyte results with greater than laboratory-defined allowable error. Samples spiked with 5% or more TPN/lipid emulsion solution or 1% D50 showed glucose concentration >500 mg/dL (>27.75 mmol/L) and produced blood gas (pH, pO 2 , pCO 2 ) results with greater than laboratory-defined allowable error. TPN/lipid emulsion, but not D50, produced greater than allowable error in electrolyte (Na + ,K + ,Ca ++ ,Hb) results at these concentrations. Based on chart review of 144 neonatal blood gas results with glucose >250 mg/dL received over seven months, four of ten neonatal intensive care unit (NICU) patients with glucose results >500 mg/dL and repeat blood gas results within 4 h had results highly suggestive of pre-analytical error. Only 3 of 36 NICU patients with glucose results 300-500 mg/dL and repeat blood gas results within 4 h had clear pre-analytical errors in blood gas results. Glucose concentration can be used as an indicator of significant blood sample contamination with either TPN

  15. Measurements of natural 41Ca concentrations

    International Nuclear Information System (INIS)

    Steinhof, A.

    1989-05-01

    Atomic mass spectroscopic examinations on 41 Ca were carried out in the UNILAC accelerator. A sensitivity of about 10 -15 was achieved. This would allow the measurement of present natural 41 Ca concentrations as soon as the problem of the transmission determination is solved. In this respect suggestions were worked out and their feasibility discussed. The detection of 41 Ca-ions is especially free of background when high UNILAC-energies are applied. An estimation showed a background level corresponding with a 41 Ca concentration of less then 10 -17 referred to 40 Ca. Besides an independent concept for the electromagnetic concentration of 41 Ca with variable concentration factors was developed. After being concentrated up to 50 respectively 25 times the initial concentration in the GSI mass separator, the 41 Ca concentration of three recent deer bones found in the Odenwald was measured by atomic mass spectroscopy in the 14UD-Pelletron Tandem in Rehovot (Israel). The measured 41 Ca concentrations ranged between 10 -14 to 10 -13 with consideration of the concentration factor. A theoretical study of the 41 Ca production in the earth's surface based on cosmic radiation illustrates the influence of trace elements on the neutron flux and thus on the 41 Ca production. This influence might be a possible explanation for the observed amplitude of variation of the 41 Ca concentration in recent bones which are of decisive importance for the feasibility of 41 Ca-related dating. In this work a method is suggested that does not depend on the amplitude of variation mentioned above and which would allow the determination of the erosion rate of rocks by its 41 Ca concentrations. (orig./HP) [de

  16. Changes in glutamate concentration, glucose metabolism, and cerebral blood flow during focal brain cooling of the epileptogenic cortex in humans.

    Science.gov (United States)

    Nomura, Sadahiro; Fujii, Masami; Inoue, Takao; He, Yeting; Maruta, Yuichi; Koizumi, Hiroyasu; Suehiro, Eiichi; Imoto, Hirochika; Ishihara, Hideyuki; Oka, Fumiaki; Matsumoto, Mishiya; Owada, Yuji; Yamakawa, Takeshi; Suzuki, Michiyasu

    2014-05-01

    Recently, focal brain cooling (FBC) was proposed as a method for treating refractory epilepsy. However, the precise influence of cooling on the molecular basis of epilepsy has not been elucidated. Thus the aim of this study was to assess the effect of FBC on glutamate (Glu) concentration, cerebral blood flow (CBF), and glucose metabolism in patients with intractable epilepsy. Nine patients underwent FBC at 15°C for 30 min prior to cortical resection (n = 6) or hippocampectomy (n = 3). Measurement of metabolites and CBF, as well as electrocorticography (ECoG), was performed. Epileptic discharge (ED), as observed by ECoG, disappeared in the cooling period and reappeared in the rewarming period. Glu concentrations were high during the precooling period and were reduced to 51.2% during the cooling period (p = 0.025). Glycerol levels showed a similar decrease (p = 0.028). Lactate concentration was high during the precooling period and was reduced during the cooling period (21.3% decrease; p = 0.005). Glucose and pyruvate levels were maintained throughout the procedure. Changes in CBF were parallel to those observed by ECoG. FBC reduced EDs and concentrations of Glu and glycerol. This demonstrates the neuroprotective effect of FBC. Our findings confirm that FBC is a reasonable and optimal treatment option for patients with intractable epilepsy. Wiley Periodicals, Inc. © 2014 International League Against Epilepsy.

  17. Application of time-resolved glucose concentration photoacoustic signals based on an improved wavelet denoising

    Science.gov (United States)

    Ren, Zhong; Liu, Guodong; Huang, Zhen

    2014-10-01

    Real-time monitoring of blood glucose concentration (BGC) is a great important procedure in controlling diabetes mellitus and preventing the complication for diabetic patients. Noninvasive measurement of BGC has already become a research hotspot because it can overcome the physical and psychological harm. Photoacoustic spectroscopy is a well-established, hybrid and alternative technique used to determine the BGC. According to the theory of photoacoustic technique, the blood is irradiated by plused laser with nano-second repeation time and micro-joule power, the photoacoustic singals contained the information of BGC are generated due to the thermal-elastic mechanism, then the BGC level can be interpreted from photoacoustic signal via the data analysis. But in practice, the time-resolved photoacoustic signals of BGC are polluted by the varities of noises, e.g., the interference of background sounds and multi-component of blood. The quality of photoacoustic signal of BGC directly impacts the precision of BGC measurement. So, an improved wavelet denoising method was proposed to eliminate the noises contained in BGC photoacoustic signals. To overcome the shortcoming of traditional wavelet threshold denoising, an improved dual-threshold wavelet function was proposed in this paper. Simulation experimental results illustrated that the denoising result of this improved wavelet method was better than that of traditional soft and hard threshold function. To varify the feasibility of this improved function, the actual photoacoustic BGC signals were test, the test reslut demonstrated that the signal-to-noises ratio(SNR) of the improved function increases about 40-80%, and its root-mean-square error (RMSE) decreases about 38.7-52.8%.

  18. Medidas corporales y concentración sérica y folicular de lípidos y glucosa en vacas Brahman fértiles y subfértiles Body measurements and serum and follicular concentrations of lipids and glucose in fertile and subfertile Brahman cows

    Directory of Open Access Journals (Sweden)

    Néstor Alonso Villa

    2009-09-01

    Full Text Available El objetivo de este estudio fue evaluar las diferencias en las medidas corporales en vacas Brahman fértiles y subfértiles, establecer las diferencias en la concentración de colesterol, lipoproteínas y glucosa en suero y líquido folicular, y desarrollar un modelo para predecir subfertilidad en vacas Brahman a partir de las medidas corporales. Se seleccionaron vacas Brahman registradas, agrupadas en fértiles (15 y subfértiles (15 según historial reproductivo. Se tomaron muestras de suero y líquido folicular (diámetro >8 mm para determinar colesterol, lipoproteínas, triacilgliceroles y glucosa. Las vacas subfértiles mostraron un fenotipo masculino, con medidas corporales mayores, y concentraciones de colesterol y HDL séricos y foliculares más bajas que las vacas fértiles. El colesterol y el HDL se correlacionaron positivamente entre los compartimientos en ambos grupos. La subfertilidad es más probable en vacas pesadas con hombros amplios y mayor perímetro torácico. El tamaño corporal en vacas Brahman subfértiles se relacionó con su apariencia, con cambios en los metabolitos séricos y foliculares y con las concentraciones de colesterol y HDL.The objective of this study was to evaluate differences in body size among Brahman cows, grouped according to their fertility, to establish differences in concentrations of cholesterol, lipoproteins, and glucose, in serum and follicular fluid, and to develop a model to predict subfertility in Brahman cows using body measurements as predictors. Registered Brahman cows were selected and grouped in fertile (15 and subfertile (15 animals, according to their calving interval. Samples of blood serum and liquid from follicles (diameter >8 mm were collected in order to determine cholesterol, lipoproteins, triacylglycerols, and glucose. Subfertile cows had a masculine phenotype, their body measurements were larger than those in fertile cows, and they had lower cholesterol and HDL concentrations in

  19. Mitochondrial oxidative stress contributes differently to rat pancreatic islet cell apoptosis and insulin secretory defects after prolonged culture in a low non-stimulating glucose concentration.

    Science.gov (United States)

    Roma, L P; Pascal, S M; Duprez, J; Jonas, J-C

    2012-08-01

    Pancreatic beta cells chronically exposed to low glucose concentrations show signs of oxidative stress, loss of glucose-stimulated insulin secretion (GSIS) and increased apoptosis. Our aim was to confirm the role of mitochondrial oxidative stress in rat islet cell apoptosis under these culture conditions and to evaluate whether its reduction similarly improves survival and GSIS. Apoptosis, oxidative stress-response gene mRNA expression and glucose-induced stimulation of mitochondrial metabolism, intracellular Ca(2+) concentration and insulin secretion were measured in male Wistar rat islets cultured for 1 week in RPMI medium containing 5-10 mmol/l glucose with or without manganese(III)tetrakis(4-benzoic acid)porphyrin (MnTBAP) or N-acetyl-L-: cysteine (NAC). Oxidative stress was measured in islet cell clusters cultured under similar conditions using cytosolic and mitochondrial redox-sensitive green fluorescent protein (roGFP1/mt-roGFP1). Prolonged culture in 5 vs 10 mmol/l glucose increased mt-roGFP1 (but not roGFP1) oxidation followed by beta cell apoptosis and loss of GSIS resulting from reduced insulin content, mitochondrial metabolism, Ca(2+) influx and Ca(2+)-induced secretion. Tolbutamide-induced, but not high K(+)-induced, Ca(2+) influx was also suppressed. Under these conditions, MnTBAP, but not NAC, triggered parallel ~50-70% reductions in mt-roGFP1 oxidation and beta cell apoptosis, but failed to protect against the loss of GSIS despite significant improvement in glucose-induced and tolbutamide-induced Ca(2+) influx. Mitochondrial oxidative stress contributes differently to rat pancreatic islet cell apoptosis and insulin secretory defects during culture in a low glucose concentration. Thus, targeting beta cell survival may not be sufficient to restore insulin secretion when beta cells suffer from prolonged mitochondrial oxidative stress, e.g. in the context of reduced glucose metabolism.

  20. Hepatic glucose output in humans measured with labeled glucose to reduce negative errors

    International Nuclear Information System (INIS)

    Levy, J.C.; Brown, G.; Matthews, D.R.; Turner, R.C.

    1989-01-01

    Steele and others have suggested that minimizing changes in glucose specific activity when estimating hepatic glucose output (HGO) during glucose infusions could reduce non-steady-state errors. This approach was assessed in nondiabetic and type II diabetic subjects during constant low dose [27 mumol.kg ideal body wt (IBW)-1.min-1] glucose infusion followed by a 12 mmol/l hyperglycemic clamp. Eight subjects had paired tests with and without labeled infusions. Labeled infusion was used to compare HGO in 11 nondiabetic and 15 diabetic subjects. Whereas unlabeled infusions produced negative values for endogenous glucose output, labeled infusions largely eliminated this error and reduced the dependence of the Steele model on the pool fraction in the paired tests. By use of labeled infusions, 11 nondiabetic subjects suppressed HGO from 10.2 +/- 0.6 (SE) fasting to 0.8 +/- 0.9 mumol.kg IBW-1.min-1 after 90 min of glucose infusion and to -1.9 +/- 0.5 mumol.kg IBW-1.min-1 after 90 min of a 12 mmol/l glucose clamp, but 15 diabetic subjects suppressed only partially from 13.0 +/- 0.9 fasting to 5.7 +/- 1.2 at the end of the glucose infusion and 5.6 +/- 1.0 mumol.kg IBW-1.min-1 in the clamp (P = 0.02, 0.002, and less than 0.001, respectively)

  1. Measurement of tritium concentration in urine

    International Nuclear Information System (INIS)

    Sekiyama, Shigenobu; Deshimaru, Takehide

    1979-01-01

    Concerning the safety management of the advanced thermal reactor ''Fugen'', the internal exposure management for tritium is important, because heavy water is used as the moderator in the reactor, and tritium is produced in the heavy water. Tritium is the radioactive nuclide with the maximum β-ray energy of 18 keV, and the radiation exposure is limited to the internal exposure in human bodies, as tritium is taken in through the skin and by breathing. The tritium concentration in urine of the operators of the Fugen plant was measured. As for tritium measurement, the analysis of raw urine, the analysis after passing through mixed ion exchange resin and the analysis after distillation are applied. The scintillator, the liquid scintillation counter, the ion exchange resin and the distillator are introduced. The preliminary survey was conducted on the urine sample, the scintillator the calibration, etc. The measuring condition, the measurement of efficiency, and the limitation of detection with various background are explained, with the many experimental data and the calculating formula. Concerning the measured tritium concentration in urine, the tritium concentrations in distilled urine, raw urine and the urine refined with ion exchange resin were compared, and the correlation formulae are presented. The actual tritium concentration value in urine was less than 50 pci/ml. The measuring methods of raw urine and the urine refined with ion exchange resin are adequate as they are quick and accurate. (Nakai, Y.)

  2. Concentration of Rutin Model Solutions from Their Mixtures with Glucose Using Ultrafiltration

    Directory of Open Access Journals (Sweden)

    Zaid S. Saleh

    2010-02-01

    Full Text Available Separation of polyphenolic phytochemical compounds from their mixtures with sugars is necessary to produce an added-value sugar-reduced extract with high biological activity from fruit juice processing industry waste streams. The separation characteristics of a binary mixture of rutin and glucose using a Pellicon-2 regenerated cellulose ultrafiltration membrane with an area of 0.1 m2 having nominal MWCO of 1,000 Da were investigated, to demonstrate the separation of phenolic compounds from sugars. The effects of the operating variables–transmembrane pressure, feed solution temperature and pH, initial feed concentration and feed flow rate–on the permeate flux and enrichment of rutin, were determined. The permeate flux increased with the increase in transmembrane pressure up to a certain limit and after that the flux remained more or less constant. The optimum transmembrane pressure was within 4–5 bar. The flux increased with the increase in feed solution temperature because of reduced feed viscosity, and better solubility. The concentration of rutin was optimum at lower temperature (30ºC, with an enrichment factor of 1.3. The effect of pH on permeate flux was less obvious. Lowering the feed solution pH increased the retention of rutin and the optimum separation was obtained within pH 3–4. The permeate flux decreased with the increase in feed concentration of rutin (concentration range 0.1–0.5 g/L. The enrichment of rutin was significant in the glucose concentration range 0.35–0.5 g/L. The feed flow rate had a significant effect on the flux and separation characteristics. Higher cross-flow through the membrane reduced the fouling by providing a shear force to sweep away deposited materials from the membrane surface. At high feed flow rate, more rutin was retained by the membrane with less sugar permeating through. The optimum feed flow rate was 1.5 L/min. For the separation of rutin (in the retentate and glucose (in the permeate, the

  3. Serum progranulin concentrations are not responsive during oral lipid tolerance test and oral glucose tolerance test.

    Science.gov (United States)

    Schmid, A; Leszczak, S; Ober, I; Schäffler, A; Karrasch, T

    2015-07-01

    The postprandial regulation of progranulin by oral uptake of lipids and carbohydrates in healthy individuals has not yet been investigated. The regulation of progranulin in 2 large cohorts of healthy volunteers during oral lipid tolerance test (OLTT; n=100) and oral glucose tolerance test (OGTT; n=100) was analyzed. One hundred healthy volunteers underwent OLTT and OGTT in an outpatient setting. Venous blood was drawn at 0 hours (h) (fasting) and at 2, 4, and 6 h in OLTT or 1 and 2 h in OGTT. A novel OLTT solution completely free of carbohydrates and protein was applied. Subjects were characterized by anthropometric and laboratory parameters. Serum concentrations of progranulin were measured by enzyme-linked immunosorbent assay (ELISA). Circulating progranulin levels remained unchanged during OLTT and OGTT. Fasting progranulin levels ranged between 31.3±8.7 and 40.6±7.7 ng/ml and were not different in subgroups addressing BMI, gender, family history, smoking habits, and hormonal contraception. There was a reciprocal correlation of progranulin with HDL (negative) and LDL cholesterol levels (positive). In healthy adults, fasting and postprandial circulating progranulin levels are not different in BMI subgroups. Oral uptake of carbohydrates and lipids does not influence circulating progranulin levels in a short-term manner. A postprandial and short-term regulation of this adipokine is absent, at least in healthy subjects. There is a negative correlation of progranulin with HDL cholesterol, but a positive correlation with LDL cholesterol. This reciprocal association might be of physiological importance for an individual's atherosclerotic risk. © Georg Thieme Verlag KG Stuttgart · New York.

  4. Measurement of concentration of heavy water

    International Nuclear Information System (INIS)

    Tsukamoto, Yuichi; Kondo, Mitsuo; Sakurai, Naoyuki

    1979-01-01

    The concentration of heavy water is measured as one of the technical management in the Fugen plant. The heavy water is used as the moderator in the reactor. The measuring method depends on the theory of light absorption. The light absorption range of heavy water spreads from near infrared to infrared zone. The near infrared absorption was adopted for the purpose, as the absorption is much larger in infrared zone, and the measurement has to be conducted, limiting the apparent absorption. This measuring method is available to determine the concentration of heavy water in the broad range exactly. The preparation of heavy water sample and the measurement of the absorption spectra of near infrared ray are explained, as the experimental procedure. The sample cell was made of quartz, and the spectroscope was the Hitachi 323 type. The resolving power is 100 nm and 27 nm for the wave length of 1000 nm and 2500 nm, respectively. Concerning the measured results, the absorption was recorded in the wave length range from 600 nm to 2600 nm, and for the heavy water concentration range from 0 to 99.77 wt. %. The peaks of absorption were located at the wave length of 1450, 1660, 1920, 1970, 2020 and 2600 nm. The three kinds of fundamental vibration mode of the molecules of both light and heavy water are shown, and the peaks belong to H 2 O, HDO and D 2 O, respectively. The relation between the absorption and the heavy water concentration, and that between the transmissivity and the wave length are shown, when the cell thickness was varied to 5 mm and 20 mm, and the heavy water concentration to 21%, 62% and 99.85%. (Nakai, Y.)

  5. Visual food cues decrease postprandial glucose concentrations in lean and obese men without affecting food intake and related endocrine parameters.

    Science.gov (United States)

    Brede, Swantje; Sputh, Annika; Hartmann, Ann-Christin; Hallschmid, Manfred; Lehnert, Hendrik; Klement, Johanna

    2017-10-01

    The abundance of highly palatable food items in our environment represents a possible cause of overconsumption. Neuroimaging studies in humans have demonstrated that watching pictures of food increases activation in brain areas involved in homeostatic and hedonic food cue processing. Nevertheless, the impact of food cues on actual food intake and metabolic parameters has not been systematically investigated. We tested the hypothesis that watching high-calorie food cues increases food intake and modifies anticipatory blood parameters in lean and especially in obese men. In 20 normal-weight and 20 obese healthy fasted men, we assessed the effects of watching pictures of high-calorie food items versus neutral contents on food intake measured during a standardized test buffet and subsequent snacking as well as on glucose homeostasis and endocrine parameters. Compared to neutral pictures, viewing food pictures reduced postprandial blood glucose concentrations in lean (p = 0.016) and obese (p = 0.044) subjects, without any differences in insulin or C-peptide concentrations (all p > 0.4). Viewing food pictures did not affect total calorie intake during the buffet (all p > 0.5) and snack consumption (all p > 0.4). Concentrations of ghrelin, adrenocorticotropic hormone (ACTH), cortisol, and glucagon also remained unaffected (all p > 0.08). These data indicate that preprandial processing of food cues curbs postprandial blood glucose excursions, without immediately affecting eating behavior in normal-weight and obese men. Findings indicate that exposure to food cues does not acutely trigger calorie overconsumption but rather improves the glucoregulatory response to food intake. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Effects of acute exposure to increased plasma branched-chain amino acid concentrations on insulin-mediated plasma glucose turnover in healthy young subjects.

    Science.gov (United States)

    Everman, Sarah; Mandarino, Lawrence J; Carroll, Chad C; Katsanos, Christos S

    2015-01-01

    Plasma branched-chain amino acids (BCAA) are inversely related to insulin sensitivity of glucose metabolism in humans. However, currently, it is not known whether there is a cause-and-effect relationship between increased plasma BCAA concentrations and decreased insulin sensitivity. To determine the effects of acute exposure to increased plasma BCAA concentrations on insulin-mediated plasma glucose turnover in humans. Ten healthy subjects were randomly assigned to an experiment where insulin was infused at 40 mU/m2/min (40U) during the second half of a 6-hour intravenous infusion of a BCAA mixture (i.e., BCAA; N = 5) to stimulate plasma glucose turnover or under the same conditions without BCAA infusion (Control; N = 5). In a separate experiment, seven healthy subjects were randomly assigned to receive insulin infusion at 80 mU/m2/min (80U) in association with the above BCAA infusion (N = 4) or under the same conditions without BCAA infusion (N = 3). Plasma glucose turnover was measured prior to and during insulin infusion. Insulin infusion completely suppressed the endogenous glucose production (EGP) across all groups. The percent suppression of EGP was not different between Control and BCAA in either the 40U or 80U experiments (P > 0.05). Insulin infusion stimulated whole-body glucose disposal rate (GDR) across all groups. However, the increase (%) in GDR was not different [median (1st quartile - 3rd quartile)] between Control and BCAA in either the 40U ([199 (167-278) vs. 186 (94-308)] or 80 U ([491 (414-548) vs. 478 (409-857)] experiments (P > 0.05). Likewise, insulin stimulated the glucose metabolic clearance in all experiments (P BCAA in either of the experiments (P > 0.05). Short-term exposure of young healthy subjects to increased plasma BCAA concentrations does not alter the insulin sensitivity of glucose metabolism.

  7. Effects of acute exposure to increased plasma branched-chain amino acid concentrations on insulin-mediated plasma glucose turnover in healthy young subjects.

    Directory of Open Access Journals (Sweden)

    Sarah Everman

    Full Text Available Plasma branched-chain amino acids (BCAA are inversely related to insulin sensitivity of glucose metabolism in humans. However, currently, it is not known whether there is a cause-and-effect relationship between increased plasma BCAA concentrations and decreased insulin sensitivity.To determine the effects of acute exposure to increased plasma BCAA concentrations on insulin-mediated plasma glucose turnover in humans.Ten healthy subjects were randomly assigned to an experiment where insulin was infused at 40 mU/m2/min (40U during the second half of a 6-hour intravenous infusion of a BCAA mixture (i.e., BCAA; N = 5 to stimulate plasma glucose turnover or under the same conditions without BCAA infusion (Control; N = 5. In a separate experiment, seven healthy subjects were randomly assigned to receive insulin infusion at 80 mU/m2/min (80U in association with the above BCAA infusion (N = 4 or under the same conditions without BCAA infusion (N = 3. Plasma glucose turnover was measured prior to and during insulin infusion.Insulin infusion completely suppressed the endogenous glucose production (EGP across all groups. The percent suppression of EGP was not different between Control and BCAA in either the 40U or 80U experiments (P > 0.05. Insulin infusion stimulated whole-body glucose disposal rate (GDR across all groups. However, the increase (% in GDR was not different [median (1st quartile - 3rd quartile] between Control and BCAA in either the 40U ([199 (167-278 vs. 186 (94-308] or 80 U ([491 (414-548 vs. 478 (409-857] experiments (P > 0.05. Likewise, insulin stimulated the glucose metabolic clearance in all experiments (P 0.05.Short-term exposure of young healthy subjects to increased plasma BCAA concentrations does not alter the insulin sensitivity of glucose metabolism.

  8. Diabetes mellitus, fasting blood glucose concentration, and risk of vascular disease: a collaborative meta-analysis of 102 prospective studies

    DEFF Research Database (Denmark)

    Sarwar, N; Gao, P; Seshasai, S R Kondapally

    2010-01-01

    Uncertainties persist about the magnitude of associations of diabetes mellitus and fasting glucose concentration with risk of coronary heart disease and major stroke subtypes. We aimed to quantify these associations for a wide range of circumstances....

  9. Relationship between fluctuations in glucose levels measured by continuous glucose monitoring and vascular endothelial dysfunction in type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Torimoto Keiichi

    2013-01-01

    Full Text Available Abstract Background Fluctuations in blood glucose level cause endothelial dysfunction and play a critical role in onset and/or progression of atherosclerosis. We hypothesized that fluctuation in blood glucose levels correlate with vascular endothelial dysfunction and that this relationship can be assessed using common bedside medical devices. Methods Fluctuations in blood glucose levels were measured over 24 hours by continuous glucose monitoring (CGM on admission day 2 in 57 patients with type 2 diabetes mellitus. The reactive hyperemia index (RHI, an index of vascular endothelial function, was measured using peripheral arterial tonometry (EndoPAT on admission day 3. Results The natural logarithmic-scaled RHI (L_RHI correlated with SD (r=−0.504; PPP=0.001 and percentage of time ≥200 mg/dl (r=−0.292; P=0.028. In 12 patients with hypoglycemia, L_RHI also correlated with the percentage of time at hypoglycemia (r=−0.589; P=0.044. L_RHI did not correlate with HbA1c or fasting plasma glucose levels. Furthermore, L_RHI did not correlate with LDL cholesterol, HDL cholesterol, and triglyceride levels or with systolic and diastolic blood pressures. Finally, multivariate analysis identified MAGE as the only significant determinant of L_RHI. Conclusions Fluctuations in blood glucose levels play a significant role in vascular endothelial dysfunction in type 2 diabetes. Trial registration UMIN000007581

  10. Relationship between postprandial changes in cardiac left ventricular function, glucose and insulin concentrations, gastric emptying, and satiety in healthy subjects

    Directory of Open Access Journals (Sweden)

    Björgell Ola

    2011-03-01

    Full Text Available Abstract Background The digestion of food is known to alter the hemodynamics of the body significantly. The purpose of this study was to study the postprandial changes in stroke volume (SV, cardiac output (CO and left ventricular (LV longitudinal systolic and diastolic functions measured with tissue Doppler imaging, in relation to gastric emptying rate (GER, satiety, and glucose and insulin concentrations in healthy subjects. Methods Twenty-three healthy subjects were included in this study. The fasting and postprandial changes at 30 min and 110 min in CO, heart rate (HR and blood pressure were measured. Moreover, tissue Doppler imaging systolic (S', early (E' and late (A' mitral annular diastolic velocities were measured in the septal (s and lateral (l walls. Glucose and insulin concentrations, and satiety were measured before and 15, 30, 45, 60, 90, and 120 min after the start of the meal. The GER was calculated as the percentage change in the antral cross-sectional area 15-90 min after ingestion of the meal. Results This study show that both CO, systolic longitudinal ventricular velocity of the septum (S's and lateral wall (S'l, the early diastolic longitudinal ventricular velocity of the lateral wall (E'l, the late diastolic longitudinal ventricular velocity of the septum (A's and lateral wall (A'l increase significantly, and were concomitant with increased satiety, antral area, glucose and insulin levels. The CO, HR and SV at 30 min were significantly higher, and the diastolic blood pressure was significantly lower, than the fasting. The satiety was correlated to HR and diastolic blood pressure. The insulin level was correlated to HR. Conclusions This study shows that postprandial CO, HR, SV and LV longitudinal systolic and diastolic functions increase concomitantly with increased satiety, antral area, and glucose and insulin levels. Therefore, patients should not eat prior to, or during, cardiac evaluation as the effects of a meal may

  11. On-line determination of glucose and lactate concentrations in animal cell culture based on fibre optic detection of oxygen in flow-injection analysis.

    Science.gov (United States)

    Dremel, B A; Li, S Y; Schmid, R D

    1992-01-01

    A flow-injection analysis (FIA) system based on fibre optic detection of oxygen consumption using immobilized glucose oxidase (GOD) and lactate oxidase (LOD) is described for the on-line monitoring of glucose and lactate concentrations in animal cell cultures. The consumption of oxygen was determined via dynamic quenching by molecular oxygen of the fluorescence of an indicator. GOD and LOD were immobilized on controlled pore glass (CPG) in enzyme reactors which were directly linked to a specially designed fibre optic flow-through cell covering the oxygen optrode. The system is linear for 0-30 mM glucose, with an r.s.d. of 5% at 30 mM (five measurements) and for 0-30 mM lactate, with an r.s.d. of 5% at 30 mM (five measurements). The enzyme reactors used were stable for more than 4 weeks in continuous operation, and it was possible to analyse up to 20 samples per hour. The system has been successfully applied to the on-line monitoring of glucose and lactate concentrations of an animal cell culture designed for the production of recombinant human antithrombine III (AT-III). Results of the on-line measurement obtained by the FIA system were compared with the off-line results obtained by a glucose and lactate analyser from Yellow Springs Instrument Company (YSI).

  12. The biphasic effect of extracellular glucose concentration on carbachol-induced fluid secretion from mouse submandibular glands.

    Science.gov (United States)

    Terachi, Momomi; Hirono, Chikara; Kitagawa, Michinori; Sugita, Makoto

    2018-06-01

    Cholinergic agonists evoke elevations of the cytoplasmic free-calcium concentration ([Ca 2+ ] i ) to stimulate fluid secretion in salivary glands. Salivary flow rates are significantly reduced in diabetic patients. However, it remains elusive how salivary secretion is impaired in diabetes. Here, we used an ex vivo submandibular gland perfusion technique to characterize the dependency of salivary flow rates on extracellular glucose concentration and activities of glucose transporters expressed in the glands. The cholinergic agonist carbachol (CCh) induced sustained fluid secretion, the rates of which were modulated by the extracellular glucose concentration in a biphasic manner. Both lowering the extracellular glucose concentration to less than 2.5 mM and elevating it to higher than 5 mM resulted in decreased CCh-induced fluid secretion. The CCh-induced salivary flow was suppressed by phlorizin, an inhibitor of the sodium-glucose cotransporter 1 (SGLT1) located basolaterally in submandibular acinar cells, which is altered at the protein expression level in diabetic animal models. Our data suggest that SGLT1-mediated glucose uptake in acinar cells is required to maintain the fluid secretion by sustaining Cl - secretion in real-time. High extracellular glucose levels may suppress the CCh-induced secretion of salivary fluid by altering the activities of ion channels and transporters downstream of [Ca 2+ ] i signals. © 2018 Eur J Oral Sci.

  13. The relationship between HbA(1c) and fasting plasma glucose in patients with increased plasma liver enzyme measurements

    DEFF Research Database (Denmark)

    Christiansen, R; Rasmussen, L Melholt; Nybo, H

    2012-01-01

    levels of increased liver enzyme concentrations. Methods:  Data from 10 065 patients with simultaneous measurement of HbA(1c) , venous fasting plasma glucose, alanine aminotransferase and γ-glutamyl transferase were extracted from our laboratory database. Correlations were investigated in four patient...

  14. A Model of Self-Monitoring Blood Glucose Measurement Error.

    Science.gov (United States)

    Vettoretti, Martina; Facchinetti, Andrea; Sparacino, Giovanni; Cobelli, Claudio

    2017-07-01

    A reliable model of the probability density function (PDF) of self-monitoring of blood glucose (SMBG) measurement error would be important for several applications in diabetes, like testing in silico insulin therapies. In the literature, the PDF of SMBG error is usually described by a Gaussian function, whose symmetry and simplicity are unable to properly describe the variability of experimental data. Here, we propose a new methodology to derive more realistic models of SMBG error PDF. The blood glucose range is divided into zones where error (absolute or relative) presents a constant standard deviation (SD). In each zone, a suitable PDF model is fitted by maximum-likelihood to experimental data. Model validation is performed by goodness-of-fit tests. The method is tested on two databases collected by the One Touch Ultra 2 (OTU2; Lifescan Inc, Milpitas, CA) and the Bayer Contour Next USB (BCN; Bayer HealthCare LLC, Diabetes Care, Whippany, NJ). In both cases, skew-normal and exponential models are used to describe the distribution of errors and outliers, respectively. Two zones were identified: zone 1 with constant SD absolute error; zone 2 with constant SD relative error. Goodness-of-fit tests confirmed that identified PDF models are valid and superior to Gaussian models used so far in the literature. The proposed methodology allows to derive realistic models of SMBG error PDF. These models can be used in several investigations of present interest in the scientific community, for example, to perform in silico clinical trials to compare SMBG-based with nonadjunctive CGM-based insulin treatments.

  15. Continuous glucose monitoring in newborn infants: how do errors in calibration measurements affect detected hypoglycemia?

    Science.gov (United States)

    Thomas, Felicity; Signal, Mathew; Harris, Deborah L; Weston, Philip J; Harding, Jane E; Shaw, Geoffrey M; Chase, J Geoffrey

    2014-05-01

    Neonatal hypoglycemia is common and can cause serious brain injury. Continuous glucose monitoring (CGM) could improve hypoglycemia detection, while reducing blood glucose (BG) measurements. Calibration algorithms use BG measurements to convert sensor signals into CGM data. Thus, inaccuracies in calibration BG measurements directly affect CGM values and any metrics calculated from them. The aim was to quantify the effect of timing delays and calibration BG measurement errors on hypoglycemia metrics in newborn infants. Data from 155 babies were used. Two timing and 3 BG meter error models (Abbott Optium Xceed, Roche Accu-Chek Inform II, Nova Statstrip) were created using empirical data. Monte-Carlo methods were employed, and each simulation was run 1000 times. Each set of patient data in each simulation had randomly selected timing and/or measurement error added to BG measurements before CGM data were calibrated. The number of hypoglycemic events, duration of hypoglycemia, and hypoglycemic index were then calculated using the CGM data and compared to baseline values. Timing error alone had little effect on hypoglycemia metrics, but measurement error caused substantial variation. Abbott results underreported the number of hypoglycemic events by up to 8 and Roche overreported by up to 4 where the original number reported was 2. Nova results were closest to baseline. Similar trends were observed in the other hypoglycemia metrics. Errors in blood glucose concentration measurements used for calibration of CGM devices can have a clinically important impact on detection of hypoglycemia. If CGM devices are going to be used for assessing hypoglycemia it is important to understand of the impact of these errors on CGM data. © 2014 Diabetes Technology Society.

  16. COMPARISON OF WHOLE BLOOD AND PLASMA GLUCOSE CONCENTRATIONS IN GREEN TURTLES ( CHELONIA MYDAS) DETERMINED USING A GLUCOMETER AND A DRY CHEMISTRY ANALYZER.

    Science.gov (United States)

    Perrault, Justin R; Bresette, Michael J; Mott, Cody R; Stacy, Nicole I

    2018-01-01

    :  We compared glucose concentrations in whole blood and plasma from green turtles ( Chelonia mydas) using a glucometer with plasma glucose analyzed by dry chemistry analyzer. Whole blood glucose (glucometer) and plasma glucose (dry chemistry) had the best agreement ( r s =0.85) and a small negative bias (-0.08 mmol/L).

  17. Associations of Body Composition Measurements with Serum Lipid, Glucose and Insulin Profile: A Chinese Twin Study

    Science.gov (United States)

    Liao, Chunxiao; Gao, Wenjing; Cao, Weihua; Lv, Jun; Yu, Canqing; Wang, Shengfeng; Zhou, Bin; Pang, Zengchang; Cong, Liming; Wang, Hua; Wu, Xianping; Li, Liming

    2015-01-01

    Objectives To quantitate and compare the associations of various body composition measurements with serum metabolites and to what degree genetic or environmental factors affect obesity-metabolite relation. Methods Body mass index (BMI), waist circumference (WC), lean body mass (LBM), percent body fat (PBF), fasting serum high density lipoprotein cholesterol (HDL-C), low density lipoprotein cholesterol (LDL-C), triglycerides (TG), total cholesterol (TC), glucose, insulin and lifestyle factors were assessed in 903 twins from Chinese National Twin Registry (CNTR). Homeostasis model assessment of insulin resistance (HOMA-IR) was calculated from fasting serum glucose and insulin. Linear regression models and bivariate structural equation models were used to examine the relation of various body composition measurements with serum metabolite levels and genetic/environmental influences on these associations, respectively. Results At individual level, adiposity measurements (BMI, WC and PBF) showed significant associations with serum metabolite concentrations in both sexes and the associations still existed in male twins when using within-MZ twin pair comparison analyses. Associations of BMI with TG, insulin and HOMA-IR were significantly stronger in male twins compared to female twins (BMI-by-sex interaction p = 0.043, 0.020 and 0.019, respectively). Comparison of various adiposity measurements with levels of serum metabolites revealed that WC explained the largest fraction of variance in serum LDL-C, TG, TC and glucose concentrations while BMI performed best in explaining variance in serum HDL-C, insulin and HOMA-IR levels. Of these phenotypic correlations, 64–81% were attributed to genetic factors, whereas 19–36% were attributed to unique environmental factors. Conclusions We observed different associations between adiposity and serum metabolite profile and demonstrated that WC and BMI explained the largest fraction of variance in serum lipid profile and insulin

  18. Evaluation of commercial glucometer test strips for potential measurement of glucose in tears.

    Science.gov (United States)

    Cha, Kyoung Ha; Jensen, Gary C; Balijepalli, Anant S; Cohan, Bruce E; Meyerhoff, Mark E

    2014-02-04

    Tear glucose measurements have been suggested as a potential alternative to blood glucose monitoring for diabetic patients. While previous work has reported that there is a correlation between blood and tear glucose levels in humans, this link has not been thoroughly established and additional clinical studies are needed. Herein, we evaluate the potential of using commercial blood glucose test strips to measure glucose in tears. Of several blood glucose strips evaluated, only one brand exhibits the low detection limit required for quantitating glucose in tears. Calibration of these strips in the range of 0-100 μM glucose with an applied potential of 150 mV to the working electrode yields a sensitivity of 0.127 nA/μM and a limit of quantitation (LOQ) of 9 μM. The strips also exhibit ≤13% error (n = 3) for 25, 50, and 75 μM glucose in the presence of 10 μM acetaminophen, 100 μM ascorbic acid, and 100 μM uric acid. Measurements of glucose in tears from nine normal (nondiabetic) fasting human subjects using strips yielded glucose values within the range of 5-148 μM (mean = 47 μM, median = 43 μM), similar to those for human tears reported by others with more complex LC-MS methods. The glucometer strip method could facilitate more clinical studies to determine whether tear glucose and blood glucose levels sufficiently correlate for application to routine measurements in tears to supplement blood glucose testing. This would be especially helpful for children, adolescents, other Type 1 diabetics, and also for Type 2 diabetics who require treatment with insulin and cannot tolerate multiple finger sticks per day.

  19. Improvements in glucose metabolism early after gastric bypass surgery are not explained by increases in total bile acids and fibroblast growth factor 19 concentrations

    DEFF Research Database (Denmark)

    Jørgensen, Nils B; Dirksen, Carsten; Bojsen-Møller, Kirstine N

    2015-01-01

    Context: Bile acids and fibroblast growth factor 19 (FGF19) have been suggested as key mediators of the improvements in glucose metabolism after Roux-en-Y gastric bypass (RYGB). Objective: To describe fasting and postprandial state total bile acid (TBA) and FGF19 concentrations before and after...... (T2D) patients and 12 normal glucose tolerant (NGT) subjects participated in the study. Intervention: A 4-hour liquid meal test was performed before and 1 week, 3 months, and 1 year after RYGB. Main Outcome Measures: We measured fasting and postprandial TBA and FGF19 concentrations. Results: Fasting...... TBA concentrations decreased in NGT subjects (P TBA was decreased in NGT subjects 1 week after RYGB (before surgery, 567...

  20. Portable method of measuring gaseous acetone concentrations.

    Science.gov (United States)

    Worrall, Adam D; Bernstein, Jonathan A; Angelopoulos, Anastasios P

    2013-08-15

    Measurement of acetone in human breath samples has been previously shown to provide significant non-invasive diagnostic insight into the control of a patient's diabetic condition. In patients with diabetes mellitus, the body produces excess amounts of ketones such as acetone, which are then exhaled during respiration. Using various breath analysis methods has allowed for the accurate determination of acetone concentrations in exhaled breath. However, many of these methods require instrumentation and pre-concentration steps not suitable for point-of-care use. We have found that by immobilizing resorcinol reagent into a perfluorosulfonic acid polymer membrane, a controlled organic synthesis reaction occurs with acetone in a dry carrier gas. The immobilized, highly selective product of this reaction (a flavan) is found to produce a visible spectrum color change which could measure acetone concentrations to less than ppm. We here demonstrate how this approach can be used to produce a portable optical sensing device for real-time, non-invasive acetone analysis. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Apparatus for measuring a concentration of radioactivity

    International Nuclear Information System (INIS)

    Tabuchi, H.; Ogushi, A.

    1978-01-01

    Disclosed is an apparatus for measuring concentration of radioactivity in a fluid circulating in a cooling system or a disposal system, etc., of a nuclear power plant (e.g. coolant), the apparatus having a plurality of sampling tubes with different diameters depending on the intensities of radioactivity, and the sampling tubes having valves for switching from one fluid to another fluid. The sampling tubes are connected to the system to a discharge pipe, and are disposed in the proximity of a radiation detector adapted to issue a signal representative of radiation. The issued signal is supplied to a multichannel pulse height analyzer and a data processing system providing an indication of the concentrations of radioactivities for respective radionuclides

  2. Venous, Arterialized-Venous, or Capillary Glucose Reference Measurements for the Accuracy Assessment of a Continuous Glucose Monitoring System

    NARCIS (Netherlands)

    Kropff, Jort; van Steen, Sigrid C.; deGraaff, Peter; Chan, Man W.; van Amstel, Rombout B. E.; DeVries, J. Hans

    2017-01-01

    Background: Different reference methods are used for the accuracy assessment of continuous glucose monitoring (CGM) systems. The effect of using venous, arterialized-venous, or capillary reference measurements on CGM accuracy is unclear. Methods: We evaluated 21 individuals with type 1 diabetes

  3. Postprandial glucose and not triglyceride concentrations are associated with carotid intima media thickness in women with normal glucose metabolism: the Hoorn prandial study.

    Science.gov (United States)

    Alssema, M; Schindhelm, R K; Dekker, J M; Diamant, M; Kostense, P J; Teerlink, T; Scheffer, P G; Nijpels, G; Heine, R J

    2008-02-01

    The present study aimed to compare the associations of postprandial glucose (ppGL) and postprandial triglycerides (ppTG) with carotid intima media thickness (cIMT) in women with normal glucose metabolism (NGM) and type 2 diabetes (DM2). Post-menopausal women (76 with NGM, 78 with DM2), received two consecutive fat-rich and two consecutive carbohydrate-rich meals on separate occasions. Blood samples were taken before and 1, 2, 4, 6 and 8h following breakfast; lunch was given at t=4. Ultrasound imaging of the carotid artery was performed to measure cIMT. In women with NGM, an increase of 1.0 mmol/l glucose following the fat-rich meals was associated with a 50 microm cIMT increase (p=0.04), and following the carbohydrate meals, an increase of 1.8 mmol/l glucose was associated with a 50 microm larger cIMT (p=0.08). These associations were not explained by classical cardiovascular risk factors. However, no association between ppGL and cIMT was found in women with DM2 and ppTG were not associated with cIMT. The association between ppGL and cIMT in normoglycaemic women suggests that ppGL in the normal range is a marker or a risk factor for atherosclerosis. Postprandial glucose levels might be a better indicator of risk than post-OGTT glucose levels or triglyceride levels.

  4. Glucose Monitoring System Based on Osmotic Pressure Measurements

    Directory of Open Access Journals (Sweden)

    Alexandra LEAL

    2011-02-01

    Full Text Available This paper presents the design and development of a prototype sensor unit for implementation in a long-term glucose monitoring system suitable for estimating glucose levels in people suffering from diabetes mellitus. The system utilizes osmotic pressure as the sensing mechanism and consists of a sensor prototype that is integrated together with a pre-amplifier and data acquisition unit for both data recording and processing. The sensor prototype is based on an embedded silicon absolute pressure transducer and a semipermeable nanoporous membrane that is enclosed in the sensor housing. The glucose monitoring system facilitates the integration of a low power microcontroller that is combined with a wireless inductive powered communication link. Experimental verification have proven that the system is capable of tracking osmotic pressure changes using albumin as a model compound, and thereby show a proof of concept for novel long term tracking of blood glucose from remote sensor nodes.

  5. A minimally invasive system for glucose area under the curve measurement using interstitial fluid extraction technology: evaluation of the accuracy and usefulness with oral glucose tolerance tests in subjects with and without diabetes.

    Science.gov (United States)

    Sakaguchi, Kazuhiko; Hirota, Yushi; Hashimoto, Naoko; Ogawa, Wataru; Sato, Toshiyuki; Okada, Seiki; Hagino, Kei; Asakura, Yoshihiro; Kikkawa, Yasuo; Kojima, Junko; Maekawa, Yasunori; Nakajima, Hiromu

    2012-06-01

    Recent studies have highlighted the importance of managing postprandial hyperglycemia, but adequate monitoring of postprandial glucose remains difficult because of wide variations in levels. We have therefore developed a minimally invasive system to monitor postprandial glucose area under the curve (AUC). This system involves no blood sampling and uses interstitial fluid glucose (IG) AUC (IG-AUC) as a surrogate marker of postprandial glucose. This study aimed to evaluate the usefulness of this system by comparing data with the findings of oral glucose tolerance tests (OGTTs) in subjects with and without diabetes. The glucose AUC monitoring system was validated by OGTTs in 37 subjects with and 10 subjects without diabetes. A plastic microneedle array was stamped on the forearm to extract IG. A hydrogel patch was then placed on the pretreated area to accumulate IG. Glucose and sodium ion concentrations in the hydrogel were measured to calculate IG-AUC at 2-h postload glucose. Plasma glucose (PG) levels were measured every 30 min to calculate reference PG-AUC. IG-AUC correlated strongly with reference PG-AUC (r=0.93) over a wide range. The level of correlation between IG-AUC and maximum PG level was also high (r=0.86). The painless nature of the technique was confirmed by the response of patients to questionnaires. The glucose AUC monitoring system using IG provided good estimates of reference PG-AUC and maximum PG level during OGTTs in subjects with and without diabetes. This system provides easy-to-use monitoring of glucose AUC, which is a good indicator of postprandial glucose.

  6. Development of a high-sensitivity and portable cell using Helmholtz resonance for noninvasive blood glucose-level measurement based on photoacoustic spectroscopy.

    Science.gov (United States)

    Tachibana, K; Okada, K; Kobayashi, R; Ishihara, Y

    2016-08-01

    We describe the possibility of high-sensitivity noninvasive blood glucose measurement based on photoacoustic spectroscopy (PAS). The demand for noninvasive blood glucose-level measurement has increased due to the explosive increase in diabetic patients. We have developed a noninvasive blood glucose-level measurement based on PAS. The conventional method uses a straight-type resonant cell. However, the cell volume is large, which results in a low detection sensitivity and difficult portability. In this paper, a small-sized Helmholtz-type resonant cell is proposed to improve detection sensitivity and portability by reducing the cell dead volume. First, the acoustic property of the small-sized Helmholtz-type resonant cell was evaluated by performing an experiment using a silicone rubber. As a result, the detection sensitivity of the small-sized Helmholtz-type resonant cell was approximately two times larger than that of the conventional straight-type resonant cell. In addition, the inside volume was approximately 30 times smaller. Second, the detection limits of glucose concentration were estimated by performing an experiment using glucose solutions. The experimental results showed that a glucose concentration of approximately 1% was detected by the small-sized Helmholtz-type resonant cell. Although these results on the sensitivity of blood glucose-level measurement are currently insufficient, they suggest that miniaturization of a resonance cell is effective in the application of noninvasive blood glucose-level measurement.

  7. Measurements of radon concentrations in dwelling houses

    International Nuclear Information System (INIS)

    Birkholz, W.; Klink, T.

    1993-01-01

    Radon and its daughter products gain in importance in health protection and radiation safety. Especially in the southern region of Saxony radon concentrations in dwellings may be high by former silver and uranium mines. We found radon contents of about 20.000 Bq/m 3 in dwellings. To redevelop such houses it is necessary to know intrude path of radon. In present work we studied different measuring systems, active and passive detectors, short and long term integrating devices. By means of investigation of radon sources several redeveloping methods are rates as well from radiological as from civil engineering point of view. (author)

  8. Effect of ionising radiation and sal of cadmium on the changes of concentrations glucose and cholesterol in serum of chickens

    International Nuclear Information System (INIS)

    Kafka, I.; Danova, D.; Kalenicova, Z.; Striskova, K.

    2008-01-01

    The present study investigated changes of concentrations glucose and cholesterol in the serum of broiler chickens exposed to single of whole-body dose of 3 Gy gamma rays and concentration of cadmium 6 mg · kg -1 live weight. Samples of our experiment was analyse on the 7, 14 and 21 day after irradiation. (authors)

  9. Polymer optical fiber compound parabolic concentrator tip for enhanced coupling efficiency for fluorescence based glucose sensors

    DEFF Research Database (Denmark)

    Hassan, Hafeez Ul; Nielsen, Kristian; Aasmul, Søren

    2015-01-01

    We demonstrate that the light excitation and capturing efficiency of fluorescence based fiber-optical sensors can be significantly increased by using a CPC (Compound Parabolic Concentrator) tip instead of the standard plane-cut tip. We use Zemax modelling to find the optimum CPC tip profile...... and fiber length of a polymer optical fiber diabetes sensor for continuous monitoring of glucose levels. We experimentally verify the improved performance of the CPC tipped sensor and the predicted production tolerances. Due to physical size requirements when the sensor has to be inserted into the body...... a non-optimal fiber length of 35 mm is chosen. For this length an average improvement in efficiency of a factor of 1.7 is experimentally demonstrated and critically compared to the predicted ideal factor of 3 in terms of parameters that should be improved through production optimization....

  10. Multiple-Input Subject-Specific Modeling of Plasma Glucose Concentration for Feedforward Control.

    Science.gov (United States)

    Kotz, Kaylee; Cinar, Ali; Mei, Yong; Roggendorf, Amy; Littlejohn, Elizabeth; Quinn, Laurie; Rollins, Derrick K

    2014-11-26

    The ability to accurately develop subject-specific, input causation models, for blood glucose concentration (BGC) for large input sets can have a significant impact on tightening control for insulin dependent diabetes. More specifically, for Type 1 diabetics (T1Ds), it can lead to an effective artificial pancreas (i.e., an automatic control system that delivers exogenous insulin) under extreme changes in critical disturbances. These disturbances include food consumption, activity variations, and physiological stress changes. Thus, this paper presents a free-living, outpatient, multiple-input, modeling method for BGC with strong causation attributes that is stable and guards against overfitting to provide an effective modeling approach for feedforward control (FFC). This approach is a Wiener block-oriented methodology, which has unique attributes for meeting critical requirements for effective, long-term, FFC.

  11. Polymer optical fiber compound parabolic concentrator tip for enhanced coupling efficiency for fluorescence based glucose sensors.

    Science.gov (United States)

    Hassan, Hafeez Ul; Nielsen, Kristian; Aasmul, Soren; Bang, Ole

    2015-12-01

    We demonstrate that the light excitation and capturing efficiency of fluorescence based fiber-optical sensors can be significantly increased by using a CPC (Compound Parabolic Concentrator) tip instead of the standard plane-cut tip. We use Zemax modelling to find the optimum CPC tip profile and fiber length of a polymer optical fiber diabetes sensor for continuous monitoring of glucose levels. We experimentally verify the improved performance of the CPC tipped sensor and the predicted production tolerances. Due to physical size requirements when the sensor has to be inserted into the body a non-optimal fiber length of 35 mm is chosen. For this length an average improvement in efficiency of a factor of 1.7 is experimentally demonstrated and critically compared to the predicted ideal factor of 3 in terms of parameters that should be improved through production optimization.

  12. Circulating asprosin concentrations are increased in type 2 diabetes mellitus and independently associated with fasting glucose and triglyceride.

    Science.gov (United States)

    Zhang, Lei; Chen, Chao; Zhou, Nan; Fu, Yuming; Cheng, Xingbo

    2017-11-03

    Asprosin has been identified as a novel hormone enriched in white adipose tissue and is pathologically increased in insulin-resistant mice and humans. However, information regarding the role of asprosin in type 2 diabetes mellitus (T2DM) remains unavailable. Via conducting a hospital-based study, we purposed to ascertain the potential relationship between circulating asprosin concentrations and T2DM. The study recruited 84 adults with T2DM and 86 controls with normal glucose tolerance. They matched in age, body mass index (BMI), and sex. Serum asprosin concentrations were measured via ELISA method. Compared to the controls, serum asprosin concentrations were significantly increased in the T2DM adults (Pglucose and triglyceride were independently associated with serum asprosin in T2DM. Asprosin concentrations are increased in adults with T2DM. The results suggest that asprosin might serve as a risk factor associated with the pathogenesis of T2DM, but not an ideal biomarker for predicting T2DM. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Simultaneous measurement of glucose blood–brain transport constants and metabolic rate in rat brain using in-vivo 1H MRS

    Science.gov (United States)

    Du, Fei; Zhang, Yi; Zhu, Xiao-Hong; Chen, Wei

    2012-01-01

    Cerebral glucose consumption and glucose transport across the blood–brain barrier are crucial to brain function since glucose is the major energy fuel for supporting intense electrophysiological activity associated with neuronal firing and signaling. Therefore, the development of noninvasive methods to measure the cerebral metabolic rate of glucose (CMRglc) and glucose transport constants (KT: half-saturation constant; Tmax: maximum transport rate) are of importance for understanding glucose transport mechanism and neuroenergetics under various physiological and pathological conditions. In this study, a novel approach able to simultaneously measure CMRglc, KT, and Tmax via monitoring the dynamic glucose concentration changes in the brain tissue using in-vivo 1H magnetic resonance spectroscopy (MRS) and in plasma after a brief glucose infusion was proposed and tested using an animal model. The values of CMRglc, Tmax, and KT were determined to be 0.44±0.17 μmol/g per minute, 1.35±0.47 μmol/g per minute, and 13.4±6.8 mmol/L in the rat brain anesthetized with 2% isoflurane. The Monte-Carlo simulations suggest that the measurements of CMRglc and Tmax are more reliable than that of KT. The overall results indicate that the new approach is robust and reliable for in-vivo measurements of both brain glucose metabolic rate and transport constants, and has potential for human application. PMID:22714049

  14. Measurement of radon activity concentration in buildings

    International Nuclear Information System (INIS)

    Godet, J.L.; Perrin, M.L.; Pineau, C.; Dechaux, E.

    2010-01-01

    Radon exposure, along with medical-related exposure, is the leading source of exposure to ionising radiation for the French population. Measurement campaigns are done in the action plan, drawn up by the French nuclear safety authority (ASN), in cooperation with the French directorate for housing, town planning and countryside (DHUP), the French radiation protection and nuclear safety institute (IRSN), the French health monitoring institute (InVS) and the French scientific and technical centre for construction (CSTB). The review of 2005-2008 measurement campaign shows that of the 7356 buildings screened, 84.8% had activity concentration levels below the 400 Bq/m 3 action level. For the other buildings (15.2%), action will be required to reduce human exposure to radon, possibly including building renovation/redevelopment work. In the 1999-2002 measurement campaign,12% of the 13,000 buildings screened had a radon activity concentration level higher than 400 Bq/m 3 . In addition, the ASN and the French general directorate of labour (DGT) are continuing to work on drawing up regulations for occupational risk management. The second national health and environment plan (PNSE 2) was published on 26 June 2009. It follows on from the actions initiated in PNSE 1, a document provided for under the Public Health Act dated 9 August 2004 and under the French 'Grenelle' environmental agreements. On the basis of guidelines laid out in PNSE 2, a radon action plan for 2009-2012 will be drawn up, enabling some of the actions to be continued, particularly in the fields of new building projects and dwellings. (author)

  15. The use of Fourier-transform infrared spectroscopy for the quantitative determination of glucose concentration in whole blood

    International Nuclear Information System (INIS)

    Shen, Y C; Davies, A G; Linfield, E H; Elsey, T S; Taday, P F; Arnone, D D

    2003-01-01

    Fourier-transform infrared transmission spectroscopy has been used for the determination of glucose concentration in whole blood samples from 28 patients. A 4-vector partial least-squares calibration model, using the spectral range 950-1200 cm -1 , yielded a standard-error-of-prediction of 0.59 mM for an independent test set. For blood samples from a single patient, we found that the glucose concentration was proportional to the difference between the values of the second derivative spectrum at 1082 cm -1 and 1093 cm -1 . This indicates that spectroscopy at these two specific wavenumbers alone could be used to determine the glucose concentration in blood plasma samples from a single patient, with a prediction error of 0.95 mM

  16. Device for measuring the tritium concentration in a measuring gas

    International Nuclear Information System (INIS)

    Koran, P.

    1987-01-01

    The measuring gas is brought into contact via a measuring gas path with a diaphragm permeable to water, which separates the measuring gas path from a counter gas path leading to a proportional detector. The measuring gas path and the counter gas path are in counterflow in the area of diaphragm. The preferably hose diaphragm consists of a well-known ion exchange material, which can be used for gas drying purposes, which is permeable to water and tritium compounds similar to water, but is impermeable to other gases and liquids contained in air, particularly rare gases. In this way, the tritium concentration can be measured with great rare gas suppression. (orig./HP) [de

  17. Effects of pH value and substrate concentration on hydrogen production from the anaerobic fermentation of glucose

    Energy Technology Data Exchange (ETDEWEB)

    Li, Zhi; Wang, Hui; Tang, Zongxun; Wang, Xiaofang [Key Laboratory of Synthetic and Natural Functional Molecule Chemistry (Ministry of Education), Department of Chemisty, Northwest University, Xi' an 710069 (China); Bai, Jinbo [Lab. MSS/MAT, CNRS UMR 8579, Ecole Centrale Paris, 92295 Chatenay Malabry (France)

    2008-12-15

    A series of batch experiments were conducted to investigate the effects of pH and glucose concentrations on biological hydrogen production by using the natural sludge obtained from the bed of a local river as inoculant. Batch experiments numbered series I and II were designed at an initial and constant pH of 5.0-7.0 with 1.0 increment and four different glucose concentrations (5.0, 7.5, 10 and 20 g glucose/L). The results showed that the optimal condition for anaerobic fermentative hydrogen production is 7.5 g glucose/L and constant pH 6.0 with a maximum H{sub 2} production rate of 0.22 mol H{sub 2} mol{sup -1} glucose h{sup -1}, a cumulative H{sub 2} yield of 1.83 mol H{sub 2} mol{sup -1} glucose and a H{sub 2} percentage of 63 in biogas. (author)

  18. In vitro evidence of glucose-induced toxicity in GnRH secreting neurons: high glucose concentrations influence GnRH secretion, impair cell viability, and induce apoptosis in the GT1-1 neuronal cell line.

    Science.gov (United States)

    Pal, Lubna; Chu, Hsiao-Pai; Shu, Jun; Topalli, Ilir; Santoro, Nanette; Karkanias, George

    2007-10-01

    To evaluate for direct toxic effects of high glucose concentrations on cellular physiology in GnRH secreting immortalized GT1-1 neurons. Prospective experimental design. In vitro experimental model using a cell culture system. GT1-1 cells were cultured in replicates in media with two different glucose concentrations (450 mg/dL and 100 mg/dL, respectively) for varying time intervals (24, 48, and 72 hours). Effects of glucose concentrations on GnRH secretion by the GT1-1 neurons were evaluated using a static culture model. Cell viability, cellular apoptosis, and cell cycle events in GT1-1 neurons maintained in two different glucose concentrations were assessed by flow cytometry (fluorescence-activated cell sorter) using Annexin V-PI staining. Adverse influences of high glucose concentrations on GnRH secretion and cell viability were noted in cultures maintained in high glucose concentration (450 mg/dL) culture medium for varying time intervals. A significantly higher percentage of cells maintained in high glucose concentration medium demonstrated evidence of apoptosis by a fluorescence-activated cell sorter. We provide in vitro evidence of glucose-induced cellular toxicity in GnRH secreting GT1-1 neurons. Significant alterations in GnRH secretion, reduced cell viability, and a higher percentage of apoptotic cells were observed in GT1-1 cells maintained in high (450 mg/dL) compared with low (100 mg/dL) glucose concentration culture medium.

  19. Glucose, fructose and sucrose increase the solubility of protein-tannin complexes and at high concentration, glucose and sucrose interfere with bisulphite bleaching of wine pigments.

    Science.gov (United States)

    Harbertson, James F; Yuan, Chunlong; Mireles, Maria S; Hanlin, Rachel L; Downey, Mark O

    2013-05-01

    Wines were modified with increasing sugar concentrations and decreasing tannin concentrations and analysed by a combination of protein precipitation and bisulphite bleaching. Increasing sugar concentration decreased the precipitation of tannin and protein-precipitable polymeric pigments (PPP). The use of a hydrogen bond disruptor (urea) to reduce protein-tannin and protein-pigment complex formation showed that the effect of sugar concentration occurred by increasing the solubility of the tannin-protein complex, not by interfering with protein-tannin complex formation. By increasing the solubility of pigment-protein complexes, non-protein-precipitable polymeric pigments (nPPP) appeared to increase. There was also an increase in total polymeric pigments at each tannin concentration with increasing glucose and sucrose concentration, indicating that sugar concentration might also affect bisulphite bleaching of wine pigments. While a significant effect of sugar concentration on tannin-protein complex solubility was observed, these effects were greatest at sugar concentrations far in excess of normal wine making conditions. Under normal wine making conditions, sugar concentration will have a negligible effect on protein-precipitable tannin, PPP and nPPP concentrations. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Continuous glucose monitoring in newborn infants: how do errors in calibration measurements affect detected hypoglycemia?

    OpenAIRE

    Thomas, Felicity Louise; Signal, Mathew; Harris, Deborah L.; Weston, Philip J.; Harding, Jane E.; Shaw, Geoffrey M.; Chase, J. Geoffrey

    2014-01-01

    Neonatal hypoglycemia is common and can cause serious brain injury. Continuous glucose monitoring (CGM) could improve hypoglycemia detection, while reducing blood glucose (BG) measurements. Calibration algorithms use BG measurements to convert sensor signals into CGM data. Thus, inaccuracies in calibration BG measurements directly affect CGM values and any metrics calculated from them. The aim was to quantify the effect of timing delays and calibration BG measurement errors on hypoglycemia me...

  1. Effects of intravenous glucose infusion and nutritional balance on serum concentrations of nonesterified fatty acids, glucose, insulin, and progesterone in nonlactating dairy cows.

    Science.gov (United States)

    Vieira, F V R; Lopes, C N; Cappellozza, B I; Scarpa, A B; Cooke, R F; Vasconcelos, J L M

    2010-07-01

    The objective of this study was to evaluate serum concentrations of nonesterified fatty acids, glucose, insulin, and progesterone in nonlactating dairy cows according to nutritional balance and glucose infusion. Ten nonlactating, ovariectomized Gir x Holstein cows were stratified by body weight (BW) and body condition score (BCS) on d -28 of the study, and randomly assigned to 1) negative nutrient balance (NB) or 2) positive nutrient balance (PB). From d -28 to d 0, cows were allocated according to nutritional treatment (5 cows/treatment) into 2 low-quality pastures with reduced forage availability. However, PB cows individually received, on average, 3 kg/cow per day (as-fed) of a concentrate during the study. All cows had an intravaginal progesterone releasing device inserted on d -14, which remained in cows until the end of the study. Cow BW and BCS were assessed again on d 0. On d 0, cows within nutritional treatment were randomly assigned to receive, in a crossover design containing 2 periods of 24h each, 1) intravenous glucose infusion (GLU; 0.5 g of glucose/kg of BW, as a 5% glucose solution administered, on average, at 32 mL/min over a 3-h period), or 2) intravenous saline infusion (SAL; 0.9% solution infused on average at 32 mL/min over a 3-h period). Prior to the beginning of each period, all cows were fasted for 12h. Blood samples were collected, relative to the beginning of the infusion, at -12 and -11.5h (beginning of fasting), and at -0.5, 0, 0.5, 1, 2, 3, 4, 5, and 6h. Following the last blood collection of period 1, cows received (PB) or not (NB) concentrate and were returned to their respective pastures. Changes in BCS and BW were greater in NB cows compared with PB cows (-0.60 and -0.25+/-0.090 for BCS, respectively; -22.4 and 1.2+/-6.58 kg for BW, respectively). Cows receiving GLUC had greater glucose concentrations from 0.5 to 3h relative to infusion compared with SAL cows. Insulin concentrations were greater in PB cows assigned to GLUC compared

  2. Short communication: Associations between blood glucose concentration, onset of hyperketonemia, and milk production in early lactation dairy cows.

    Science.gov (United States)

    Ruoff, J; Borchardt, S; Heuwieser, W

    2017-07-01

    The objectives of this study were to describe the associations between hypoglycemia and the onset of hyperketonemia (HYK) within the first 6 wk of lactation, to evaluate the effects of body condition score at calving on glucose concentration, and to study the effects of hypoglycemia on milk production. A total of 621 dairy cows from 6 commercial dairy farms in Germany were enrolled between 1 and 4 d in milk (DIM). Cows were tested twice weekly using an electronic handheld meter for glucose and β-hydroxybutyrate (BHB), respectively, for a period of 42 d. Hypoglycemia was defined as glucose concentration ≤2.2 mmol/L. Hyperketonemia was defined as a BHB concentration ≥1.2 mmol/L. The onset of HYK was described as early onset (first HYK event within the first 2 wk postpartum) and late onset (first HYK event in wk 3 to 6 postpartum). The effect of ketosis status on blood glucose within 42 DIM was evaluated using a generalized linear mixed model. No effect was observed of HYK on glucose concentration in primiparous cows. Multiparous cows with early-onset HYK had a lower glucose concentration (-0.21 mmol/L) compared with nonketotic cows. Overall, primiparous cows had a lower prevalence and incidence of hypoglycemia than multiparous cows. Hypoglycemia in multiparous cows was associated with higher first test-day milk production and 100 DIM milk production. In conclusion, hypoglycemia mainly occurred in multiparous cows with early-onset HYK, whereas primiparous cows were at a lower risk for hypoglycemia. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  3. Measurement of gluconeogenesis using glucose fragments and mass spectrometry after ingestion of deuterium oxide

    NARCIS (Netherlands)

    Chacko, Shaji K.; Sunehag, Agneta L.; Sharma, Susan; Sauer, Pieter J. J.; Haymond, Morey W.

    We report a new method to measure the fraction of glucose derived from gluconeogenesis using gas chromatography-mass spectrometry and positive chemical ionization. After ingestion of deuterium oxide by subjects, glucose derived from gluconeogenesis is labeled with deuterium. Our calculations of

  4. Measurement of gluconeogenesis using glucose fragments and mass spectrometry after ingestion of deuterium oxide.

    Science.gov (United States)

    We report a new method to measure the fraction of glucose derived from gluconeogenesis using gas chromatography-mass spectrometry and positive chemical ionization. After ingestion of deuterium oxide by subjects, glucose derived from gluconeogenesis is labeled with deuterium. Our calculations of gluc...

  5. Glucose Pump Test can be Used to Measure Blood Flow Rate of ...

    African Journals Online (AJOL)

    The aim of study is to determine whether glucose pump test (GPT) is used for surveillance of native AV fistulas by using Doppler US as reference. Methods: In 93 chronic hemodialysis patients with native AV fistula, blood flow rates were measured by Doppler US and GPT. For GPT, glucose was infused to 16 mL/min by ...

  6. Venous, Arterialized-Venous, or Capillary Glucose Reference Measurements for the Accuracy Assessment of a Continuous Glucose Monitoring System.

    Science.gov (United States)

    Kropff, Jort; van Steen, Sigrid C; deGraaff, Peter; Chan, Man W; van Amstel, Rombout B E; DeVries, J Hans

    2017-11-01

    Different reference methods are used for the accuracy assessment of continuous glucose monitoring (CGM) systems. The effect of using venous, arterialized-venous, or capillary reference measurements on CGM accuracy is unclear. We evaluated 21 individuals with type 1 diabetes using a capillary calibrated CGM system. Venous or arterialized-venous reference glucose samples were taken every 15 min at two separate visits and assessed per YSI 2300 STAT Plus. Arterialization was achieved by heated-hand technique. Capillary samples were collected hourly during the venous reference visit. The investigation sequence (venous or arterialized-venous) was randomized. Effectiveness of arterialization was measured by comparing free venous oxygen pressure (PO2) of both visit days. Primary endpoint was the median absolute relative difference (ARD). Median ARD using arterialized-venous reference samples was not different from venous samples (point estimated difference 0.52%, P = 0.181). When comparing the three reference methods, median ARD was also not different over the full glycemic range (venous 9.0% [n = 681], arterialized-venous 8.3% [n = 684], and capillary 8.1% [n = 205], P = 0.216), nor over the separate glucose ranges. Arterialization was successful (PO2 venous 5.4 kPa vs. arterialized-venous 8.9 kPa, P reference measurements did not significantly impact CGM accuracy. Venous reference seems preferable due to its ease of operation.

  7. Non-invasive method to detect the changes of glucose concentration in whole blood using photometric technique.

    Science.gov (United States)

    Rajan, Shiny Amala Priya; Towe, Bruce C

    2014-01-01

    A non-invasive method is developed to monitor rapid changes in blood glucose levels in diabetic patients. The system depends on an optical cell built with a LED that emits light of wavelength 535nm, which is a peak absorbance of hemoglobin. As the glucose concentration in blood decreases, its osmolarity also decreases and the Red Blood Cells (RBCs) swell and decrease the path length absorption coefficient. Decreasing absorption coefficient increases the transmission of light through the whole blood. The system was tested with a constructed optical cell that held whole blood in a capillary tube. As expected the light transmitted to the photodiode increases with decreasing glucose concentration. The average response time of the system was between 30-40 seconds.

  8. Increasing synthetic serum substitute (SSS) concentrations in P1 glucose/phosphate-free medium improves implantation rate: a comparative study.

    Science.gov (United States)

    Ben-Yosef, D; Yovel, I; Schwartz, T; Azem, F; Lessing, J B; Amit, A

    2001-11-01

    To assess the comparative efficacy of IVF medium (MediCult, with 5.2 mM glucose) and a glucose/phosphate-free medium, P1 (Irvine Scientific), and to investigate the influence of increasing the serum supplementation (synthetic serum substitute; SSS; Irvine Scientific) to P1 on embryo development and implantation. Patients were randomly assigned to IVF medium (Group 1, cycles n = 172) or P1 supplemented with 10% SSS (Group 2, cycles n = 229) according to the medium scheduled for use on the day of oocyte retrieval. Another 555 IVF consequent cycles (Group 3) were performed using increased SSS concentrations (20%) in P1 medium. In this large series of IVF cycles, we herein demonstrate that significantly higher pregnancy and implantation rates were found when embryos were cultured in glucose/phosphate-free medium P1 supplemented with 20% SSS compared to supplementation with the lower SSS concentration and with IVF medium.

  9. Underestimation of glucose turnover measured with [6-3H]- and [6,6-2H]- but not [6-14C]glucose during hyperinsulinemia in humans

    International Nuclear Information System (INIS)

    McMahon, M.M.; Schwenk, W.F.; Haymond, M.W.; Rizza, R.A.

    1989-01-01

    Recent studies indicate that hydrogen-labeled glucose tracers underestimate glucose turnover in humans under conditions of high flux. The cause of this underestimation is unknown. To determine whether the error is time-, pool-, model-, or insulin-dependent, glucose turnover was measured simultaneously with [6-3H]-, [6,6-2H2]-, and [6-14C]glucose during a 7-h infusion of either insulin (1 mU.kg-1.min-1) or saline. During the insulin infusion, steady-state glucose turnover measured with both [6-3H]glucose (8.0 +/- 0.5 mg.kg-1.min-1) and [6,6-2H2]glucose (7.6 +/- 0.5 mg.kg-1.min-1) was lower (P less than .01) than either the glucose infusion rate required to maintain euglycemia (9.8 +/- 0.7 mg.kg-1.min-1) or glucose turnover determined with [6-14C]glucose and corrected for Cori cycle activity (9.8 +/- 0.7 mg.kg-1.min-1). Consequently negative glucose production rates (P less than .01) were obtained with either [6-3H]- or [6,6-2H2]- but not [6-14C]glucose. The difference between turnover estimated with [6-3H]glucose and actual glucose disposal (or 14C glucose flux) did not decrease with time and was not dependent on duration of isotope infusion. During saline infusion, estimates of glucose turnover were similar regardless of the glucose tracer used. High-performance liquid chromatography of the radioactive glucose tracer and plasma revealed the presence of a tritiated nonglucose contaminant. Although the contaminant represented only 1.5% of the radioactivity in the [6-3H]glucose infusate, its clearance was 10-fold less (P less than .001) than that of [6-3H]glucose. This resulted in accumulation in plasma, with the contaminant accounting for 16.6 +/- 2.09 and 10.8 +/- 0.9% of what customarily is assumed to be plasma glucose radioactivity during the insulin or saline infusion, respectively (P less than .01)

  10. Effects of Zinc Supplementation on the Anthropometric Measurements, Lipid Profiles and Fasting Blood Glucose in the Healthy Obese Adults

    Directory of Open Access Journals (Sweden)

    Sepide Mahluji

    2013-02-01

    Full Text Available Purpose: The aim of this study was to assess the effects of zinc supplementation on anthropometric measures, improving lipid profile biomarkers, and fasting blood glucose level in obese people. Methods: This randomized, double- blind clinical trial was carried out on 60 obese participants in the 18-45 age range for one month. The participants were randomly divided into the intervention group, who received 30 mg/d zinc gluconate, and the placebo group who received 30mg/d starch. Anthropometric measurements (body mass index (BMI, weight and waist circumference were recorded before and at the end of study. Lipid profile biomarkers and fasting blood glucose were determined using enzymatic procedure. Analysis of Covariance (ANCOVA test was run to compare the post-treatment values of the two groups, and t-test was conducted to compare within group changes. Results: Serum zinc concentration was increased significantly in intervention group (p=0.024. BMI and body weight was significantly decreased (p=0.030 and p=0.020, respectively. Lipid profile biomarkers and fating blood glucose did not change significantly but triglyceride level was significantly decreased (p=0.006 in the intervention group. Conclusion: The obtained results indicate that zinc supplementation improves BMI, body weight, and triglyceride concentration without considerable effects on lipid profile and glucose level. Zinc can be suggested as a suitable supplementation therapy for obese people, but more studies are needed to verify the results.

  11. Copeptin, a surrogate marker for arginine vasopressin secretion, is associated with higher glucose and insulin concentrations but not higher blood pressure in obese men

    DEFF Research Database (Denmark)

    Asferg, C L; Andersen, Ulrik Bjørn; Linneberg, A

    2014-01-01

    distribution. METHODS: In 103 obese men (mean age ± standard deviation: 49.4 ± 10.2 years) and 27 normal weight control men (mean age: 51.5 ± 8.4 years), taking no medication, we measured 24-h ambulatory blood pressure, fasting blood concentrations of copeptin, lipids, glucose and insulin, and determined body...... blood pressure (r = 0.11, P = 0.29), 24-h diastolic blood pressure (r = 0.11, P = 0.28), BMI (r = 0.09, P = 0.37), total body fatness percentage (r = 0.10, P = 0.33), android fat mass percentage (r = 0.04, P = 0.66) or serum triglyceride concentrations (r = 0.04; P = 0.68). In contrast, plasma copeptin......, and is associated with abnormalities in glucose and insulin metabolism, but not with higher blood pressure or an android fat distribution in obese men....

  12. Assessment of circulating betatrophin concentrations in lean glucose-tolerant women with polycystic ovary syndrome.

    Science.gov (United States)

    Erol, Onur; Özel, Mustafa Kemal; Ellidağ, Hamit Yaşar; Toptaş, Tayfun; Derbent, Aysel Uysal; Yılmaz, Necat

    2017-07-01

    The aims of the current study were to investigate the betatrophin levels in lean glucose-tolerant women with polycystic ovary syndrome (PCOS), and to explore the relationships between these levels and antropometric, hormonal and metabolic parameters. The study population consisted of 50 lean (body mass index [BMI] production and improved glucose tolerance. Few studies have investigated the association between PCOS and betatrophin. However, in contrast to our study, the authors included overweight/obese patients and glucose tolerance was not evaluated before recruitment. What the results of this study add: Our results showed that serum betatrophin levels were significantly higher in lean glucose-tolerant PCOS women than in age- and BMI-matched healthy controls. What are the implications of these findings for clinical practice and/or further research: Elevated betatrophin levels in PCOS women, in the absence of obesity and glucose intolerance, may reflect a compensatory mechanism in order to counteract metabolic syndrome-related risk factors.

  13. Uranium concentrations in fossils measured by SIMS

    International Nuclear Information System (INIS)

    Uyeda, Chiaki; Okano, Jun

    1988-01-01

    Semiquantitative analyses of uranium in fossil bones and teeth were carried out by SIMS. The results show a tendency that uranium concentrations in the fossils increase with the ages of the fossils. It is noticed that fossil bones and teeth having uranium concentration of more than several hundred ppm are not rare. (author)

  14. Glucose concentration in capillary blood of dairy cows obtained by a minimally invasive lancet technique and determined with three different hand-held devices.

    Science.gov (United States)

    Mair, B; Drillich, M; Klein-Jöbstl, D; Kanz, P; Borchardt, S; Meyer, L; Schwendenwein, I; Iwersen, M

    2016-02-24

    Dairy cows have a massive demand for glucose at the onset of lactation. A poor adaption to this period leads to an excessive negative energy balance with an increased risk for ketosis and impaired animal health and production. Besides the measurement of ketones, analysing the glucose concentration in blood is reported as helpful instrument for diagnosis and differentiation of ketosis. Monitoring metabolic parameters requires multiple blood sampling. In other species, new blood sampling techniques have been introduced in which small amounts of blood are rapidly analysed using electronic hand-held devices. The objective of this study was to evaluate the suitability of capillary blood for blood glucose measurement in dairy cows using the hand-held devices FreeStyle Precision (FSP, Abbott), GlucoMen LX Plus (GLX, A. Menarini) and the WellionVet GLUCO CALEA, (WGC, MED TRUST). In total, 240 capillary blood samples were obtained from dry and fresh lactating Holstein-Friesian cows. Blood was collected from the skin of the exterior vulva by using a lancet. For method comparison, additional blood samples were taken from a coccygeal vessel and analyzed in a laboratory. Glucose concentrations measured by a standard laboratory method were defined as the criterion standard. The Pearson correlation coefficients between the glucose concentrations analyzed in capillary blood with the devices and the reference were 73% for the FSP, 81% for the GLX and 41% for the WGC. Bland-Altman plots showed biases of -18.8 mg/dL for the FSP, -11.2 mg/dL for the GLX and +20.82 mg/dL for the WGC. The optimized threshold determined by a Receiver Operating Characteristics analysis to detect hyperglycemia using the FSP was 43 mg/dL with a sensitivity (Se) and specificity (Sp) of 76 and 80%. Using the GLX and WGC optimized thresholds were 49 mg/dL (Se = 92%, Sp = 85%) and 95 mg/dL (Se = 39%, Sp = 92%). The results of this study demonstrate good performance characteristics for the GLX

  15. Radiolysis of 2-[{sup 18}F]fluoro-2-deoxy-D-glucose ([{sup 18}F]FDG) and the role of ethanol and radioactive concentration

    Energy Technology Data Exchange (ETDEWEB)

    Jacobson, Mark S. [Division of Nuclear Medicine, Mayo Clinic, Rochester, MN (United States)], E-mail: jacobson.mark17@mayo.edu; Dankwart, Heather R. [Division of Nuclear Medicine, Mayo Clinic, Rochester, MN (United States); Mahoney, Douglas W. [Division of Biostatistics, Mayo Clinic, Rochester, MN (United States)

    2009-06-15

    Radiolysis is the process by which radioactively labeled compounds degrade. Many positron emission tomography (PET) radiopharmaceuticals produced with high radioactive concentrations and specific activities exhibit low radiochemical purity because of radiolysis. Little data exist that describe the radiolytic decomposition of 2-[{sup 18}F]fluoro-2-deoxy-D-glucose ([{sup 18}F]FDG). The objective of our study was to profile the degradation of [{sup 18}F]FDG at various radioactive concentrations by measuring radiochemical purity at different time intervals and to study the effects of ethanol, a well-known reductant stabilizer of [{sup 18}F]FDG preparations.

  16. High Glucose Concentration Promotes Vancomycin-Enhanced Biofilm Formation of Vancomycin-Non-Susceptible Staphylococcus aureus in Diabetic Mice.

    Directory of Open Access Journals (Sweden)

    Chi-Yu Hsu

    Full Text Available We previously demonstrated that vancomycin treatment increased acquisition of eDNA and enhanced biofilm formation of drug-resistant Staphylococcus aureus through a cidA-mediated autolysis mechanism. Recently we found that such enhancement became more significant under a higher glucose concentration in vitro. We propose that besides improper antibiotic treatment, increased glucose concentration environment in diabetic animals may further enhance biofilm formation of drug-resistant S. aureus. To address this question, the diabetic mouse model infected by vancomycin-resistant S. aureus (VRSA was used under vancomycin treatment. The capacity to form biofilms was evaluated through a catheter-associated biofilm assay. A 10- and 1000-fold increase in biofilm-bound bacterial colony forming units was observed in samples from diabetic mice without and with vancomycin treatment, respectively, compared to healthy mice. By contrast, in the absence of glucose vancomycin reduced propensity to form biofilms in vitro through the increased production of proteases and DNases from VRSA. Our study highlights the potentially important role of increased glucose concentration in enhancing biofilm formation in vancomycin-treated diabetic mice infected by drug-resistant S. aureus.

  17. Plasma Asprosin Concentrations Are Increased in Individuals with Glucose Dysregulation and Correlated with Insulin Resistance and First-Phase Insulin Secretion

    Directory of Open Access Journals (Sweden)

    Yuren Wang

    2018-01-01

    Full Text Available Background. Adipokines are reported to participate in many common pathologic processes of glucose dysregulation, such as insulin resistance, β-cell dysfunction, and chronic inflammation. Objective. To detect the concentrations of plasma asprosin in subjects with impaired glucose regulation (IGR and newly diagnosed type 2 diabetes (nT2DM and its relationship to parameters of glucose and lipid metabolism, insulin resistance, and pancreatic β-cell function. Methods. 143 eligible participants were included and were divided into three groups including normal glucose regulation (NGR, n=52, IGR (n=40, and nT2DM group (n=51. The intravenous glucose tolerance test (IVGTT and clinical and biochemical parameters were measured in all participants. Results. Plasma asprosin levels were higher in IGR (82.40 ± 91.06 ng/mL, P<0.001 and nT2DM (73.25 ± 91.69 ng/mL, P<0.001 groups compared with those in the NGR (16.22 ± 9.27 ng/mL group, especially in IGR subjects. Correlation analysis showed that plasma asprosin levels were positively correlated with waist circumference (Wc, fasting plasma glucose (FPG, postchallenge plasma glucose (2hPG, HbA1c, triglyceride (TG, and homeostasis model assessment for insulin resistance (HOMA-IR and negatively correlated with homeostasis model assessment for β-cell function (HOMA-β, area under the curve of the first-phase (0–10 min insulin secretion (AUC, acute insulin response (AIR, and glucose disposition index (GDI (all P<0.05. Multiple logistical regression analyses revealed that plasma asprosin concentrations were significantly correlated with IGR and nT2DM after controlling for age, sex, BMI, and WHR. Conclusions. Circulating asprosin might be a predictor of early diagnosis in DM and might be a potential therapeutic target for prediabetes and T2DM.

  18. High glucose concentration induces endothelial cell proliferation by regulating cyclin-D2-related miR-98.

    Science.gov (United States)

    Li, Xin-Xin; Liu, Yue-Mei; Li, You-Jie; Xie, Ning; Yan, Yun-Fei; Chi, Yong-Liang; Zhou, Ling; Xie, Shu-Yang; Wang, Ping-Yu

    2016-06-01

    Cyclin D2 is involved in the pathology of vascular complications of type 2 diabetes mellitus (T2DM). This study investigated the role of cyclin-D2-regulated miRNAs in endothelial cell proliferation of T2DM. Results showed that higher glucose concentration (4.5 g/l) significantly promoted the proliferation of rat aortic endothelial cells (RAOECs), and significantly increased the expression of cyclin D2 and phosphorylation of retinoblastoma 1 (p-RB1) in RAOECs compared with those under low glucose concentration. The cyclin D2-3' untranslated region is targeted by miR-98, as demonstrated by miRNA analysis software. Western blot also confirmed that cyclin D2 and p-RB1 expression was regulated by miR-98. The results indicated that miR-98 treatment can induce RAOEC apoptosis. The suppression of RAOEC growth by miR-98 might be related to regulation of Bcl-2, Bax and Caspase 9 expression. Furthermore, the expression levels of miR-98 decreased in 4.5 g/l glucose-treated cells compared with those treated by low glucose concentration. Similarly, the expression of miR-98 significantly decreased in aortas of established streptozotocin (STZ)-induced diabetic rat model compared with that in control rats; but cyclin D2 and p-RB1 levels remarkably increased in aortas of STZ-induced diabetic rats compared with those in healthy control rats. In conclusion, this study demonstrated that high glucose concentration induces cyclin D2 up-regulation and miR-98 down-regulation in the RAOECs. By regulating cyclin D2, miR-98 can inhibit human endothelial cell growth, thereby providing novel therapeutic targets for vascular complication of T2DM. © 2016 The Authors. Journal of Cellular and Molecular Medicine published by John Wiley & Sons Ltd and Foundation for Cellular and Molecular Medicine.

  19. Comparison of Glucose Area Under the Curve Measured Using Minimally Invasive Interstitial Fluid Extraction Technology with Continuous Glucose Monitoring System in Diabetic Patients

    OpenAIRE

    Uemura, Mei

    2017-01-01

    Background: Continuous glucose monitoring (CGM) is reported to be a useful technique, but difficult or inconvenient for some patients and institutions. We are developing a glucose area under the curve (AUC) monitoring system without blood sampling using a minimally invasive interstitial fluid extraction technology (MIET). Here we evaluated the accuracy of interstitial fluid glucose (IG) AUC measured by MIET in patients with diabetes for an extended time interval and the potency of detecting h...

  20. Comparison of Glucose Area Under the Curve Measured Using Minimally Invasive Interstitial Fluid Extraction Technology with Continuous Glucose Monitoring System in Diabetic Patients

    OpenAIRE

    Mei Uemura; Yutaka Yano; Toshinari Suzuki; Taro Yasuma; Toshiyuki Sato; Aya Morimoto; Samiko Hosoya; Chihiro Suminaka; Hiromu Nakajima; Esteban C. Gabazza; Yoshiyuki Takei

    2017-01-01

    Background Continuous glucose monitoring (CGM) is reported to be a useful technique, but difficult or inconvenient for some patients and institutions. We are developing a glucose area under the curve (AUC) monitoring system without blood sampling using a minimally invasive interstitial fluid extraction technology (MIET). Here we evaluated the accuracy of interstitial fluid glucose (IG) AUC measured by MIET in patients with diabetes for an extended time interval and the potency of detecting hy...

  1. The measurement of the nigrostriatal dopaminergic function and glucose metabolism in patients with movement disorders

    Energy Technology Data Exchange (ETDEWEB)

    Otsuka, Makoto; Ichiya, Yuichi; Kuwabara, Yasuo; Sasaki, Masayuki; Fukumura, Toshimitsu; Masuda, Kouji; Shima, Fumio; Kato, Motohiro [Kyushu Univ., Fukuoka (Japan). Faculty of Medicine

    1992-12-01

    The nigrostriatal dopaminergic function and glucose metabolism were evaluated in 34 patients with various movement disorders by using positron emission tomography with [sup 18]F-Dopa and [sup 18]F-FDG respectively. The [sup 18]F-Dopa uptake in the striatum (the caudate head and the putamen) decreased in patients with Parkinson's disease but was relatively unaffected in the caudate. The cerebral glucose metabolism was normal in patients with Parkinson's disease. The [sup 18]F-Dopa uptake in the striatum also decreased in cases of atypical parkinsonism and in cases of progressive supranuclear palsy, but there was no difference in the uptake between the caudate and the putamen. The glucose metabolism decreased in the cerebral hemisphere including the striatum; this finding was also different from those of Parkinson's disease. A normal [sup 18]F-Dopa uptake in the striatum with a markedly decreased striatal glucose metabolism and a mildly decreased cortical glucose metabolism was observed in cases of Huntington's disease and Wilson's disease. The [sup 18]F-Dopa uptake in the striatum increased and the glucose metabolism was normal in cases of idiopathic dystonia. Various patterns of [sup 18]F-Dopa uptake and glucose metabolism were thus observed in the various movement disorders. These results suggest that the measurements of the [sup 18]F-Dopa uptake and the cerebral glucose metabolism would be useful for the evaluation of the striatal function in various movement disorders. (author).

  2. Peri and Postparturient Concentrations of Lipid Lipoprotein Insulin and Glucose in Normal Dairy Cows

    OpenAIRE

    BAŞOĞLU, Abdullah; SEVİNÇ, Mutlu; OK, Mahmut

    1998-01-01

    In order to provide uniqe insight into the metabolic disturbences seen after calving cholesterol, triglycerid, high density lipoprotein, low density lipoprotein, very low density lipoprotein, glucose and insulin levels in serum were studied before calving (group I), in aerly (group II) and late (group III) lactation in 24 normal cows. Serum lipoproteins were separeted into various density classes by repeated ultracentrifugation. The results indicate that there was a rise in glucose, trygl...

  3. Measuring Concentration in Data with an Exogenous Order

    OpenAIRE

    Abedieh, Jasmin; Groll, Andreas; Eugster, Manuel J. A.

    2013-01-01

    Concentration measures order the statistical units under observation according to their market share. However, there are situations where an order according to an exogenous variable is more appropriate or even required. The present article introduces a generalized definition of market concentration and defines a corresponding concentration measure. It is shown that this generalized concept of market concentration satisfies the common axioms of (classical) concentration measures. In an appl...

  4. Validation of different measures of insulin sensitivity of glucose metabolism in dairy cows using the hyperinsulinemic euglycemic clamp test as the gold standard.

    Science.gov (United States)

    De Koster, J; Hostens, M; Hermans, K; Van den Broeck, W; Opsomer, G

    2016-10-01

    The aim of the present research was to compare different measures of insulin sensitivity in dairy cows at the end of the dry period. To do so, 10 clinically healthy dairy cows with a varying body condition score were selected. By performing hyperinsulinemic euglycemic clamp (HEC) tests, we previously demonstrated a negative association between the insulin sensitivity and insulin responsiveness of glucose metabolism and the body condition score of these animals. In the same animals, other measures of insulin sensitivity were determined and the correlation with the HEC test, which is considered as the gold standard, was calculated. Measures derived from the intravenous glucose tolerance test (IVGTT) are based on the disappearance of glucose after an intravenous glucose bolus. Glucose concentrations during the IVGTT were used to calculate the area under the curve of glucose and the clearance rate of glucose. In addition, glucose and insulin data from the IVGTT were fitted in the minimal model to derive the insulin sensitivity parameter, Si. Based on blood samples taken before the start of the IVGTT, basal concentrations of glucose, insulin, NEFA, and β-hydroxybutyrate were determined and used to calculate surrogate indices for insulin sensitivity, such as the homeostasis model of insulin resistance, the quantitative insulin sensitivity check index, the revised quantitative insulin sensitivity check index and the revised quantitative insulin sensitivity check index including β-hydroxybutyrate. Correlation analysis revealed no association between the results obtained by the HEC test and any of the surrogate indices for insulin sensitivity. For the measures derived from the IVGTT, the area under the curve for the first 60 min of the test and the Si derived from the minimal model demonstrated good correlation with the gold standard. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Use of continuous glucose monitoring as an outcome measure in clinical trials.

    Science.gov (United States)

    Beck, Roy W; Calhoun, Peter; Kollman, Craig

    2012-10-01

    Although developed to be a management tool for individuals with diabetes, continuous glucose monitoring (CGM) also has potential value for the assessment of outcomes in clinical studies. We evaluated using CGM as such an outcome measure. Data were analyzed from six previously completed inpatient studies in which both CGM (Freestyle Navigator™ [Abbott Diabetes Care, Alameda, CA] or Guardian(®) [Medtronic, Northridge, CA]) and reference glucose measurements were available. The analyses included 97 days of data from 93 participants with type 1 diabetes (age range, 5-57 years; mean, 18 ± 12 years). Mean glucose levels per day were similar for the CGM and reference measurements (median, 148 mg/dL vs. 143 mg/dL, respectively; P = 0.92), and the correlation of the two was high (r = 0.89). Similarly, most glycemia metrics showed no significant differences comparing CGM and reference values, except that the nadir glucose tended to be slightly lower and peak glucose slightly higher with reference measurements than CGM measurements (respective median, 59 mg/dL vs. 66 mg/dL [P = 0.05] and 262 mg/dL vs. 257 mg/dL [P = 0.003]) and glucose variability as measured with the coefficient of variation was slightly lower with CGM than reference measurements (respective median, 31% vs. 35%; Pblood glucose measurements. CGM inaccuracy and underestimation of the extremes of hyperglycemia and hypoglycemia can be accounted for in a clinical trial's study design. Thus, in appropriate settings, CGM can be a very meaningful and feasible outcome measure for clinical trials.

  6. Accuracy of Continuous Glucose Monitoring Measurements in Normo-Glycemic Individuals

    DEFF Research Database (Denmark)

    Akintola, Abimbola A; Noordam, Raymond; Jansen, Steffy W

    2015-01-01

    a 24-hour period. Validity of CGM-derived individual glucose measurements, calculated measures of glycemia over daytime (09:00h-23:00h) and nighttime (23:00h-09:00h), and calculated measures of glycemic variability (e.g. 24h standard deviation [SD]) were assessed by Pearson correlation coefficients......, mean absolute relative difference (MARD) and paired t-tests. RESULTS: The median correlation coefficient between CGM and venous glucose measurements per participant was 0.68 (interquartile range: 0.40-0.78), and the MARD was 17.6% (SD = 17%). Compared with venous sampling, the calculated measure...

  7. Metabolic response to MMS-mediated DNA damage in Saccharomyces cerevisiae is dependent on the glucose concentration in the medium.

    Science.gov (United States)

    Kitanovic, Ana; Walther, Thomas; Loret, Marie Odile; Holzwarth, Jinda; Kitanovic, Igor; Bonowski, Felix; Van Bui, Ngoc; Francois, Jean Marie; Wölfl, Stefan

    2009-06-01

    Maintenance and adaptation of energy metabolism could play an important role in the cellular ability to respond to DNA damage. A large number of studies suggest that the sensitivity of cells to oxidants and oxidative stress depends on the activity of cellular metabolism and is dependent on the glucose concentration. In fact, yeast cells that utilize fermentative carbon sources and hence rely mainly on glycolysis for energy appear to be more sensitive to oxidative stress. Here we show that treatment of the yeast Saccharomyces cerevisiae growing on a glucose-rich medium with the DNA alkylating agent methyl methanesulphonate (MMS) triggers a rapid inhibition of respiration and enhances reactive oxygen species (ROS) production, which is accompanied by a strong suppression of glycolysis. Further, diminished activity of pyruvate kinase and glyceraldehyde-3-phosphate dehydrogenase upon MMS treatment leads to a diversion of glucose carbon to glycerol, trehalose and glycogen accumulation and an increased flux through the pentose-phosphate pathway. Such conditions finally result in a significant decline in the ATP level and energy charge. These effects are dependent on the glucose concentration in the medium. Our results clearly demonstrate that calorie restriction reduces MMS toxicity through increased respiration and reduced ROS accumulation, enhancing the survival and recovery of cells.

  8. Requirements for Successful Adoption of a Glucose Measurement System Into a Hospital POC Program.

    Science.gov (United States)

    Füzéry, Anna K; Cembrowski, George S

    2016-07-01

    Widespread and successful implementation of any glucose measurement system in a hospital point-of-care (POC) program requires a number of features in addition to accurate and reliable analytical performance. Such features include, but are not limited to, a system's glucose-hematocrit dependence, durability, information technology capabilities, and battery capacity and battery life. While the study of Ottiger et al in this issue supports the analytical accuracy and reliability of Bayer's CONTOUR XT® blood glucose monitoring system, the suitability of other features of this system for a hospital POC program remains to be established. © 2016 Diabetes Technology Society.

  9. Turbidimetry for measurement of radon concentration

    International Nuclear Information System (INIS)

    Wang Huanqiang

    1993-01-01

    This paper describes a turbidimetric technique counting the tracks registered on CR-39 foils exposed to radon. Instead of eyeview through microscope, by using the differential spectrophotometer, strong correlation between the radon cumulative concentration and track turbidence was observed(r=0.999). Under the etching condition of 7.07 mol·L -1 KOH water solution at 80 o C for 16 hr, linear regression showed that the ratio of track turbidence and cumulative concentration of radon exposure was 1.99 x 10 -1 turbidence (KBq m -1 h) -1 and the determination limit was 36 KBq m -3 h. The details of the experiments are represented in this paper. (Author)

  10. Radon concentration measurements in therapeutic spring water

    International Nuclear Information System (INIS)

    Deak, N.; Horvath, A.; Sajo B, L.; Marx, G.

    1996-01-01

    It is believed that people undergoing a curative cycle in a given spa, may receive a dose in the range of 400 mSv/year which is many times the average annual dose so that their risk of lung cancer may increase by 3% or more. To determine the risk due to the natural radioactivity, of the most frequented spas in Budapest (H), we selected four and some others located on the country side being of particular interest. Results of the radon concentration in spring water are presented, with the evidence that some spas have a high radon concentration. We conclude that patients receiving treatment may be exposed to an additional dose in the range of 29-76 mSv/year that at the bronchia could be between 445-1182 mSv/year. (authors). 6 refs., 2 figs., 2 tabs

  11. Glucose concentrations modulate brain-derived neurotrophic factor responsiveness of neurones in the paraventricular nucleus of the hypothalamus.

    Science.gov (United States)

    McIsaac, W; Ferguson, A V

    2017-04-01

    The hypothalamic paraventricular nucleus (PVN) is critical for normal energy balance and has been shown to contain high levels of both brain-derived neurotrophic factor (BDNF) and tropomyosin-receptor kinase B mRNA. Microinjections of BDNF into the PVN increase energy expenditure, suggesting that BDNF plays an important role in energy homeostasis through direct actions in this nucleus. The present study aimed to examine the postsynaptic effects of BDNF on the membrane potential of PVN neurones, and also to determine whether extracellular glucose concentrations modulated these effects. We used hypothalamic PVN slices from male Sprague-Dawley rats to perform whole cell current-clamp recordings from PVN neurones. BDNF was bath applied at a concentration of 2 nmol L -1 and the effects on membrane potential determined. BDNF caused depolarisations in 54% of neurones (n=25; mean±SEM, 8.9±1.2 mV) and hyperpolarisations in 23% (n=11; -6.7±1.4 mV), whereas the remaining cells were unaffected. These effects were maintained in the presence of tetrodotoxin (n=9; 56% depolarised, 22% hyperpolarised, 22% nonresponders), or the GABA a antagonist bicuculline (n=12; 42% depolarised, 17% hyperpolarised, 41% nonresponders), supporting the conclusion that these effects on membrane potential were postsynaptic. Current-clamp recordings from PVN neurones next examined the effects of BDNF on these neurones at varying extracellular glucose concentrations. Larger proportions of PVN neurones hyperpolarised in response to BDNF as the glucose concentrations decreased [10 mmol L -1 glucose 23% (n=11) of neurones hyperpolarised, whereas, at 0.2 mmol L -1 glucose, 71% showed hyperpolarising effects (n=12)]. Our findings reveal that BDNF has direct GABA A independent effects on PVN neurones, which are modulated by local glucose concentrations. The latter observation further emphasises the critical importance of using physiologically relevant conditions in an investigation of the central

  12. [Designing and implementation of a web-based quality monitoring system for plasma glucose measurement in multicenter population study].

    Science.gov (United States)

    Liu, Yong; Wang, Limin; Pang, Richard; Mo, Nanxun; Hu, Yan; Deng, Qian; Hu, Zhaohui

    2015-05-01

    The aim of this paper is to describe the designing and implementation of a web-based plasma glucose measurement quality monitoring system to assess the analytical quality of plasma glucose measurements in multicenter population study and provide evidence for the future studies. In the chronic non-communicable disease and related factor surveillance in China, a web based quality monitoring system for plasma glucose measurement was established to conduct evaluation on plasma glucose monitoring quality and effectiveness in 302 surveillance centers, including quality control data entry, transmission and feedback. The majority of the surveillance centers met the quality requirements and passed the evaluation of reproducibility and precision of plasma glucose measurement, only a few centers required intensive training and re-assessment. In order to ensure the completeness and reliability of plasma glucose measurement in the surveillance centers, the establishment of web-based plasma glucose measurement quality control system can facilitate the identification of the qualified surveillance centers and evaluation of plasma glucose measurement quality in different regions. Communication and training are important in ensuring plasma glucose measurement quality. It is necessary to further improve this web-based plasma glucose measurement quality monitoring system in the future to reduce the method specific plasma glucose measurement bias.

  13. Requirements for Successful Adoption of a Glucose Measurement System Into a Hospital POC Program

    OpenAIRE

    F?z?ry, Anna K.; Cembrowski, George S.

    2016-01-01

    Widespread and successful implementation of any glucose measurement system in a hospital point-of-care (POC) program requires a number of features in addition to accurate and reliable analytical performance. Such features include, but are not limited to, a system?s glucose-hematocrit dependence, durability, information technology capabilities, and battery capacity and battery life. While the study of Ottiger et al in this issue supports the analytical accuracy and reliability of Bayer?s CONTO...

  14. Accuracy of Capillary and Arterial Whole Blood Glucose Measurements Using a Glucose Meter in Patients under General Anesthesia in the Operating Room.

    Science.gov (United States)

    Karon, Brad S; Donato, Leslie J; Larsen, Chelsie M; Siebenaler, Lindsay K; Wells, Amy E; Wood-Wentz, Christina M; Shirk-Marienau, Mary E; Curry, Timothy B

    2017-09-01

    The aim of this study was to evaluate the use of a glucose meter with surgical patients under general anesthesia in the operating room. Glucose measurements were performed intraoperatively on 368 paired capillary and arterial whole blood samples using a Nova StatStrip (Nova Biomedical, USA) glucose meter and compared with 368 reference arterial whole blood glucose measurements by blood gas analyzer in 196 patients. Primary outcomes were median bias (meter minus reference), percentage of glucose meter samples meeting accuracy criteria for subcutaneous insulin dosing as defined by Parkes error grid analysis for type 1 diabetes mellitus, and accuracy criteria for intravenous insulin infusion as defined by Clinical and Laboratory Standards Institute guidelines. Time under anesthesia, patient position, diabetes status, and other variables were studied to determine whether any affected glucose meter bias. Median bias (interquartile range) was -4 mg/dl (-9 to 0 mg/dl), which did not differ from median arterial meter bias of -5 mg/dl (-9 to -1 mg/dl; P = 0.32). All of the capillary and arterial glucose meter values met acceptability criteria for subcutaneous insulin dosing, whereas only 89% (327 of 368) of capillary and 93% (344 of 368) arterial glucose meter values met accuracy criteria for intravenous insulin infusion. Time, patient position, and diabetes status were not associated with meter bias. Capillary and arterial blood glucose measured using the glucose meter are acceptable for intraoperative subcutaneous insulin dosing. Whole blood glucose on the meter did not meet accuracy guidelines established specifically for more intensive (e.g., intravenous insulin) glycemic control in the acute care environment.

  15. Kinetics of the glucose/glycine Maillard reaction pathways: influences of pH and reactant initial concentrations

    NARCIS (Netherlands)

    Martins, S.I.F.S.; Boekel, van M.A.J.S.

    2005-01-01

    A previously proposed kinetic model for the glucose/glycine Maillard reaction pathways has been validated by changing the initial pH (4.8, 5.5, 6.0, 6.8 and 7.5) of the reaction and reactant initial concentrations (1:2 and 2:1 molar ratios were compared to the 1:1 ratio). The model consists of 10

  16. Measurement of glucose area under the curve using minimally invasive interstitial fluid extraction technology: evaluation of glucose monitoring concepts without blood sampling.

    Science.gov (United States)

    Sato, Toshiyuki; Okada, Seiki; Hagino, Kei; Asakura, Yoshihiro; Kikkawa, Yasuo; Kojima, Junko; Watanabe, Toshihiro; Maekawa, Yasunori; Isobe, Kazuki; Koike, Reona; Nakajima, Hiromu; Asano, Kaoru

    2011-12-01

    Monitoring postprandial hyperglycemia is crucial in treating diabetes, although its dynamics make accurate monitoring difficult. We developed a new technology for monitoring postprandial hyperglycemia using interstitial fluid (ISF) extraction technology without blood sampling. The glucose area under the curve (AUC) using this system was measured as accumulated ISF glucose (IG) with simultaneous calibration with sodium ions. The objective of this study was to evaluate this technological concept in healthy individuals. Minimally invasive ISF extraction technology (MIET) comprises two steps: pretreatment with microneedles and ISF accumulation over a specific time by contact with a solvent. The correlation between glucose and sodium ion levels using MIET was evaluated in 12 subjects with stable blood glucose (BG) levels during fasting. BG and IG time courses were evaluated in three subjects to confirm their relationship while BG was fluctuating. Furthermore, the accuracy of glucose AUC measurements by MIET was evaluated several hours after a meal in 30 subjects. A high correlation was observed between glucose and sodium ion levels when BG levels were stable (R=0.87), indicating that sodium ion is a good internal standard for calibration. The variation in IG and BG with MIET was similar, indicating that IG is an adequate substitute for BG. Finally, we showed a strong correlation (R=0.92) between IG-AUC and BG-AUC after a meal. These findings validate the adequacy of glucose AUC measurements using MIET. Monitoring glucose using MIET without blood sampling may be beneficial to patients with diabetes.

  17. Intraperitoneal lactate/pyruvate ratio and the level of glucose and glycerol concentration differ between patients surgically treated for upper and lower perforations of the gastrointestinal tract

    DEFF Research Database (Denmark)

    Sabroe, Jonas E; Axelsen, Anne R; Ellebæk, Mark B

    2017-01-01

    collected every 4th hour for up to 7 postoperative days. Samples were analysed for concentrations of glucose, lactate, pyruvate and glycerol. RESULTS: Microdialysis results showed that patients with upper gastrointestinal tract lesions had significantly higher levels of postoperative intraperitoneal glucose...... and glycerol concentrations, as well as lower lactate/pyruvate ratios and lactate/glucose ratios. In the group with perforation of the lower gastrointestinal tract, those patients with a complicated course showed lower levels of postoperative intraperitoneal glucose concentration and glycerol concentration...... and higher lactate/pyruvate ratios and lactate/glucose ratios than those patients with an uncomplicated course. CONCLUSION: Patients with upper and lower gastrointestinal tract lesions showed differences in postoperative biomarker levels. A difference was also seen between patients with complicated...

  18. Measuring glucose cerebral metabolism in the healthy mouse using hyperpolarized C-13 magnetic resonance

    DEFF Research Database (Denmark)

    Mishkovsky, Mor; Anderson, Brian; Karlsson, Magnus

    2017-01-01

    The mammalian brain relies primarily on glucose as a fuel to meet its high metabolic demand. Among the various techniques used to study cerebral metabolism, C-13 magnetic resonance spectroscopy (MRS) allows following the fate of C-13-enriched substrates through metabolic pathways. We herein...... glucose is split into 3-carbon intermediates by aldolase. This unique method allows direct detection of glycolysis in vivo in the healthy brain in a noninvasive manner....... demonstrate that it is possible to measure cerebral glucose metabolism in vivo with sub-second time resolution using hyperpolarized C-13 MRS. In particular, the dynamic C-13-labeling of pyruvate and lactate formed from C-13-glucose was observed in real time. An ad-hoc synthesis to produce [2,3,4,6,6-H-2(5), 3...

  19. Glycated haemoglobin may in future be reported as estimated mean blood glucose concentration--secondary publication

    DEFF Research Database (Denmark)

    Borg, R.; Nerup, J.; Nathan, D.M.

    2009-01-01

    Glycated haemoglobin (HbA 1c ) is widely used to determine levels of chronic glycaemia, to judge the adequacy of diabetes treatment and to adjust therapy. HbA 1c results are expressed as the percentage of HbA that is glycated. Day-to-day management is guided by self-monitoring of capillary glucose...

  20. A Negative Correlation Between Blood Glucose and Acetone Measured in Healthy and Type 1 Diabetes Mellitus Patient Breath.

    Science.gov (United States)

    Rydosz, Artur

    2015-07-01

    Exhaled acetone analysis has long been recognized as a supplementary tool for diagnosis and monitoring diabetes, especially type 1 diabetes. It is essential, therefore to determine the relationship between exhaled acetone concentration and glucose in blood. Usually, a direct linear correlation between this both compounds has been expected. However, in some cases we can observe a reverse correlation. When blood glucose was increasing, breath acetone declined. The breath analysis as a supplementary tool for diagnosing and monitoring diabetes makes sense only in case of utilization of portable analyzers. This need has created a market for gas sensors. However, commercially available acetone gas sensors are developed for measuring samples at several tens part per million. The exhaled acetone concentration was measured using commercial acetone gas sensor (TGS 822, 823 Figaro, Arlington Heights, IL, USA Inc) with micropreconcentrator in low temperature cofired ceramics. The reference analyzer-mass spectrometry (HPR-20 QIC, Hiden Analytical, Warrington, UK) was used. Twenty-two healthy volunteers with no history of any respiratory disease participated in the research, as did 31 patients diagnosed with type 1 diabetes. Respectively, 3 healthy volunteer and 5 type 1 diabetes mellitus subjects with reverse trend were selected. The linear fitting coefficient various from 0.1139 to 0.9573. Therefore, it is necessary to determine the correlation between blood glucose concentrations and under different conditions, for example, insulin levels, as well as correlate the results with clinical tests, for example, Hb1Ac. It is well known that the concentration of acetone is strongly influenced by diet, insulin treatment, and so on. Therefore, much more complex analysis with long-term measurements are required. Thus, presented results should be regarded as tentative, and validation studies with the analysis of clinical test and in a large number of patients, including control groups

  1. A preliminary verification of the floating reference measurement method for non-invasive blood glucose sensing

    Science.gov (United States)

    Min, Xiaolin; Liu, Rong; Fu, Bo; Xu, Kexin

    2017-06-01

    In the non-invasive sensing of blood glucose by near-infrared diffuse reflectance spectroscopy, the spectrum is highly susceptible to the unstable and complicated background variations from the human body and the environment. In in vitro analyses, background variations are usually corrected by the spectrum of a standard reference sample that has similar optical properties to the analyte of interest. However, it is hard to find a standard sample for the in vivo measurement. Therefore, the floating reference measurement method is proposed to enable relative measurements in vivo, where the spectra under some special source-detector distance, defined as the floating reference position, are insensitive to the changes in glucose concentration due to the absorption effect and scattering effect. Because the diffuse reflectance signals at the floating reference positions only reflect the information on background variations during the measurement, they can be used as the internal reference. In this paper, the theoretical basis of the floating reference positions in a semi-infinite turbid medium was discussed based on the steady-state diffusion equation and its analytical solutions in a semi-infinite turbid medium (under the extrapolated boundary conditions). Then, Monte-Carlo (MC) simulations and in vitro experiments based on a custom-built continuous-moving spatially resolving double-fiber NIR measurement system, configured with two types of light source, a super luminescent diode (SLD) and a super-continuum laser, were carried out to verify the existence of the floating reference position in 5%, 10% and 20% Intralipid solutions. The results showed that the simulation values of the floating reference positions are close to the theoretical results, with a maximum deviation of approximately 0.3 mm in 1100-1320 nm. Great differences can be observed in 1340-1400 nm because the optical properties of Intralipid in this region don not satisfy the conditions of the steady

  2. EFSA Panel on Dietetic Products, Nutrition and Allerg ies (NDA) ; Guidance on the scientific requirements for health claims related to appetite ratings, weight management, and blood glucose concentrations

    DEFF Research Database (Denmark)

    Tetens, Inge

    The European Food Safety Authority (EFSA) asked the Panel on Dietetic Products, Nutrition and Allergies (NDA) to draft guidance on scientific requirements for health claims related to appetite ratings, weight management, and blood glucose concentrations. This guidance has been drawn from scientific...... and studies/outcome measures which are acceptable. Rather, it presents examples drawn from evaluations already carried out in order to illustrate the approach of the Panel, as well as some examples which are currently under consideration within ongoing evaluations. A draft of this guidance document, endorsed...

  3. Consumption of meat is associated with higher fasting glucose and insulin concentrations regardless of glucose and insulin genetic risk scores: a meta-analysis of 50,345 Caucasians12

    Science.gov (United States)

    Fretts, Amanda M; Follis, Jack L; Nettleton, Jennifer A; Lemaitre, Rozenn N; Ngwa, Julius S; Wojczynski, Mary K; Kalafati, Ioanna Panagiota; Varga, Tibor V; Frazier-Wood, Alexis C; Houston, Denise K; Lahti, Jari; Ericson, Ulrika; van den Hooven, Edith H; Mikkilä, Vera; Kiefte-de Jong, Jessica C; Mozaffarian, Dariush; Rice, Kenneth; Renström, Frida; North, Kari E; McKeown, Nicola M; Feitosa, Mary F; Kanoni, Stavroula; Smith, Caren E; Garcia, Melissa E; Tiainen, Anna-Maija; Sonestedt, Emily; Manichaikul, Ani; van Rooij, Frank JA; Dimitriou, Maria; Raitakari, Olli; Pankow, James S; Djoussé, Luc; Province, Michael A; Hu, Frank B; Lai, Chao-Qiang; Keller, Margaux F; Perälä, Mia-Maria; Rotter, Jerome I; Hofman, Albert; Graff, Misa; Kähönen, Mika; Mukamal, Kenneth; Johansson, Ingegerd; Ordovas, Jose M; Liu, Yongmei; Männistö, Satu; Uitterlinden, André G; Deloukas, Panos; Seppälä, Ilkka; Psaty, Bruce M; Cupples, L Adrienne; Borecki, Ingrid B; Franks, Paul W; Arnett, Donna K; Nalls, Mike A; Eriksson, Johan G; Orho-Melander, Marju; Franco, Oscar H; Lehtimäki, Terho; Dedoussis, George V; Meigs, James B; Siscovick, David S

    2015-01-01

    Background: Recent studies suggest that meat intake is associated with diabetes-related phenotypes. However, whether the associations of meat intake and glucose and insulin homeostasis are modified by genes related to glucose and insulin is unknown. Objective: We investigated the associations of meat intake and the interaction of meat with genotype on fasting glucose and insulin concentrations in Caucasians free of diabetes mellitus. Design: Fourteen studies that are part of the Cohorts for Heart and Aging Research in Genomic Epidemiology consortium participated in the analysis. Data were provided for up to 50,345 participants. Using linear regression within studies and a fixed-effects meta-analysis across studies, we examined 1) the associations of processed meat and unprocessed red meat intake with fasting glucose and insulin concentrations; and 2) the interactions of processed meat and unprocessed red meat with genetic risk score related to fasting glucose or insulin resistance on fasting glucose and insulin concentrations. Results: Processed meat was associated with higher fasting glucose, and unprocessed red meat was associated with both higher fasting glucose and fasting insulin concentrations after adjustment for potential confounders [not including body mass index (BMI)]. For every additional 50-g serving of processed meat per day, fasting glucose was 0.021 mmol/L (95% CI: 0.011, 0.030 mmol/L) higher. Every additional 100-g serving of unprocessed red meat per day was associated with a 0.037-mmol/L (95% CI: 0.023, 0.051-mmol/L) higher fasting glucose concentration and a 0.049–ln-pmol/L (95% CI: 0.035, 0.063–ln-pmol/L) higher fasting insulin concentration. After additional adjustment for BMI, observed associations were attenuated and no longer statistically significant. The association of processed meat and fasting insulin did not reach statistical significance after correction for multiple comparisons. Observed associations were not modified by genetic

  4. The influence of sodium propionate on blood glucose, insulin and cortisol concentrations in calves of different ages

    Directory of Open Access Journals (Sweden)

    Biljana Radojičić

    2016-01-01

    Full Text Available The process of gluconeogenesis in ruminants is under the direct influence of insulin and glucocorticoid hormones. The goal of this study was to determine the effects of added Na-propionate on the neuroendocrine regulation of blood glucose in calves at three specific physiological periods: on exclusive milk nutrition; on mixed milk and forage nutrition; and with established ruminant digestion. The influence of Na-propionate on blood glucose, insulin and cortisol concentrations was examined in the same 20 female Holstein calves at different stages of forestomach development (15 days, 2 months, and 4 months of age of calves. Group 1 of calves (n = 10 received Na-propionate intravenously; group 2 (n = 10 received Na-propionate mixed in milk. Blood sampling was performed 1 and 3 h after Na-propionate administration. After i.v. administration of Na-propionate, a significant increase (P < 0.05 in blood glucose concentration was observed 1 h after administration only in calves aged 2 and 4 months; blood insulin concentration was significantly higher (P < 0.01 1 and 3 h after i.v. administration in 2-month-old calves; and cortisol concentration increased (P < 0.01 1 h after administration in each selected calf in all testing periods. Orally administered Na-propionate led to a significant increase (P < 0.01 of insulin concentration 1 and 3 h after administration in 15-day-old calves, and 3 h after administration in 2-month-old calves. Based on these results it could be assumed that i.v. and p.o. administration of Na-propionate affects the neuroendocrine regulation of glycaemia in calves of different age.

  5. Concomitant Intake of Quercetin with a Grain-Based Diet Acutely Lowers Postprandial Plasma Glucose and Lipid Concentrations in Pigs

    Directory of Open Access Journals (Sweden)

    Silvia Wein

    2014-01-01

    Full Text Available Treatment goals of diabetes mellitus type 2 (DMT2 include glycemic control and reduction of nonglycemic risk factors, for example, dyslipidemia. Quercetin, a plant-derived polyphenol, often discussed for possible antidiabetic effects, was investigated for acute postprandial glucose- and lipid-lowering effects in healthy growing pigs. Male pigs (n = 16, body weight = BW 25–30 kg were fed flavonoid-poor grain-based meals without (GBM or with quercetin (GBMQ. In a first experiment, postprandial plasma concentrations of glucose, nonesterified fatty acids (NEFA, and triacylglycerols were analyzed in 8 pigs receiving 500 g of either GBM or GBMQ (10 mg/kg BW in a cross-over design. Blood samples were collected before, and up to 5 h every 30 min, as well as 6 and 8 h after the feeding. In the second experiment, 2 h after ingestions of 1000 g of either GBM or GBMQ (50 mg/kg BW animals were sacrificed; gastric content was collected and analyzed for dry matter content. Quercetin ingestion reduced postprandial glucose, NEFA, and TG concentration, but two hours after ingestion of the meal no effect on gastric emptying was observed. Our results point to inhibitory effects of quercetin on nutrient absorption, which appear not to be attributable to delayed gastric emptying.

  6. Evidence for brain glucose dysregulation in Alzheimer's disease.

    Science.gov (United States)

    An, Yang; Varma, Vijay R; Varma, Sudhir; Casanova, Ramon; Dammer, Eric; Pletnikova, Olga; Chia, Chee W; Egan, Josephine M; Ferrucci, Luigi; Troncoso, Juan; Levey, Allan I; Lah, James; Seyfried, Nicholas T; Legido-Quigley, Cristina; O'Brien, Richard; Thambisetty, Madhav

    2018-03-01

    It is unclear whether abnormalities in brain glucose homeostasis are associated with Alzheimer's disease (AD) pathogenesis. Within the autopsy cohort of the Baltimore Longitudinal Study of Aging, we measured brain glucose concentration and assessed the ratios of the glycolytic amino acids, serine, glycine, and alanine to glucose. We also quantified protein levels of the neuronal (GLUT3) and astrocytic (GLUT1) glucose transporters. Finally, we assessed the relationships between plasma glucose measured before death and brain tissue glucose. Higher brain tissue glucose concentration, reduced glycolytic flux, and lower GLUT3 are related to severity of AD pathology and the expression of AD symptoms. Longitudinal increases in fasting plasma glucose levels are associated with higher brain tissue glucose concentrations. Impaired glucose metabolism due to reduced glycolytic flux may be intrinsic to AD pathogenesis. Abnormalities in brain glucose homeostasis may begin several years before the onset of clinical symptoms. Copyright © 2017 the Alzheimer's Association. All rights reserved.

  7. Double-label autoradiographic deoxyglucose method for sequential measurement of regional cerebral glucose utilization

    Energy Technology Data Exchange (ETDEWEB)

    Redies, C; Diksic, M; Evans, A C; Gjedde, A; Yamamoto, Y L

    1987-08-01

    A new double-label autoradiographic glucose analog method for the sequential measurement of altered regional cerebral metabolic rates for glucose in the same animal is presented. This method is based on the sequential injection of two boluses of glucose tracer labeled with two different isotopes (short-lived /sup 18/F and long-lived /sup 3/H, respectively). An operational equation is derived which allows the determination of glucose utilization for the time period before the injection of the second tracer; this equation corrects for accumulation and loss of the first tracer from the metabolic pool occurring after the injection of the second tracer. An error analysis of this operational equation is performed. The double-label deoxyglucose method is validated in the primary somatosensory (''barrel'') cortex of the anesthetized rat. Two different rows of whiskers were stimulated sequentially in each rat; the two periods of stimulation were each preceded by an injection of glucose tracer. After decapitation, dried brain slices were first exposed, in direct contact, to standard X-ray film and then to uncoated, ''tritium-sensitive'' film. Results show that the double-label deoxyglucose method proposed in this paper allows the quantification and complete separation of glucose utilization patterns elicited by two different stimulations sequentially applied in the same animal.

  8. Benfotiamine increases glucose oxidation and downregulates NADPH oxidase 4 expression in cultured human myotubes exposed to both normal and high glucose concentrations

    OpenAIRE

    Fraser, D. A.; Hessvik, N. P.; Nikolić, N.; Aas, V.; Hanssen, K. F.; Bøhn, S. K.; Thoresen, G. H.; Rustan, A. C.

    2011-01-01

    The aim of the present work was to study the effects of benfotiamine (S-benzoylthiamine O-monophosphate) on glucose and lipid metabolism and gene expression in differentiated human skeletal muscle cells (myotubes) incubated for 4 days under normal (5.5 mM glucose) and hyperglycemic (20 mM glucose) conditions. Myotubes established from lean, healthy volunteers were treated with benfotiamine for 4 days. Glucose and lipid metabolism were studied with labeled precursors. Gene expression was measu...

  9. The measurement of the nigrostriatal dopaminergic function and glucose metabolism in patients with movement disorders

    Energy Technology Data Exchange (ETDEWEB)

    Otsuka, Makoto; Ichiya, Yuichi; Kuwabara, Yasuo; Sasaki, Masayuki; Fukumura, Toshimitsu; Masuda, Kouji; Shima, Fumio; Kato, Motohiro (Kyushu Univ., Fukuoka (Japan). Faculty of Medicine)

    1992-12-01

    The nigrostriatal dopaminergic function and glucose metabolism were evaluated in 34 patients with various movement disorders by using positron emission tomography with [sup 18]F-Dopa and [sup 18]F-FDG respectively. The [sup 18]F-Dopa uptake in the striatum (the caudate head and the putamen) decreased in patients with Parkinson's disease but was relatively unaffected in the caudate. The cerebral glucose metabolism was normal in patients with Parkinson's disease. The [sup 18]F-Dopa uptake in the striatum also decreased in cases of atypical parkinsonism and in cases of progressive supranuclear palsy, but there was no difference in the uptake between the caudate and the putamen. The glucose metabolism decreased in the cerebral hemisphere including the striatum; this finding was also different from those of Parkinson's disease. A normal [sup 18]F-Dopa uptake in the striatum with a markedly decreased striatal glucose metabolism and a mildly decreased cortical glucose metabolism was observed in cases of Huntington's disease and Wilson's disease. The [sup 18]F-Dopa uptake in the striatum increased and the glucose metabolism was normal in cases of idiopathic dystonia. Various patterns of [sup 18]F-Dopa uptake and glucose metabolism were thus observed in the various movement disorders. These results suggest that the measurements of the [sup 18]F-Dopa uptake and the cerebral glucose metabolism would be useful for the evaluation of the striatal function in various movement disorders. (author).

  10. Advances in deuterium dioxide concentration measurement

    Energy Technology Data Exchange (ETDEWEB)

    Shon, Woojung [University of Science & Technology, Daejeon (Korea, Republic of); Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Yim, Sung Paal, E-mail: nspyim@kaeri.re.kr [University of Science & Technology, Daejeon (Korea, Republic of); Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Lee, Lim; Park, Hyunmin [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Kwang Rag; Chung, Hongsuk [University of Science & Technology, Daejeon (Korea, Republic of); Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Lee, Cheo Kyung [Handong Global University, Pohang (Korea, Republic of)

    2016-11-01

    Highlights: • Heavy water (D{sub 2}O) with a high purity level is necessary for nuclear fusion application. • D{sub 2}O purity is analyzed using Fourier Transform infrared (FT-IR) spectroscopy and newly introduced off-axis integrated cavity output spectroscopy (OA-ICOS). • OA-ICOS has advantages in terms of analysis of D{sub 2}O vapor. • OA-ICOS is expected that it can be used for accurate isotopic analyses in the future. - Abstract: The deuterium–tritium (D–T) reaction has been identified as the most efficient reaction for fusion devices. Deuterium can be obtained by heavy water electrolysis. Heavy water (D{sub 2}O) with a high purity level is necessary for nuclear fusion application. A D{sub 2}O isotopic analysis is thus very important. A system for a heavy water analysis was built and a newly designed isotopic analysis experiment was carried out. We tried to analyze the D{sub 2}O purity using Fourier Transform infrared (FT-IR) spectroscopy and newly introduced off-axis integrated cavity output spectroscopy (OA-ICOS). We found that the OA-ICOS based on measurement via laser absorption spectroscopy shows very high sensitivity. We ameliorated the sensitivity by an order of magnitude of more than 10{sup 3}–10{sup 5}. We could make the apparatus smaller by employing very tiny diode laser and fiber optics elements of a DFB (Distributed Feedback) type. Consequently, our device has advantages in terms of maintainability and mobility even in a radioactive environment. This new method could be used for an accurate isotopic analysis in the future.

  11. Detection of glutathione based on MnO2 nanosheet-gated mesoporous silica nanoparticles and target induced release of glucose measured with a portable glucose meter.

    Science.gov (United States)

    Tan, Qingqing; Zhang, Ruirui; Kong, Rongmei; Kong, Weisu; Zhao, Wenzhi; Qu, Fengli

    2017-12-08

    The authors describe a novel method for the determination of glutathione (GSH). Detection is based on target induced release of glucose from MnO 2 nanosheet-gated aminated mesoporous silica nanoparticles (MSNs). In detail, glucose is loaded into the pores of MSNs. Negatively charged MnO 2 nanosheets are assembled on the MSNs through electrostatic interactions. The nanosheets are reduced by GSH, and this results in the release of glucose which is quantified by using a commercial electrochemical glucose meter. GSH can be quantified by this method in the 100 nM to 10 μM concentration range, with a 34 nM limit of detection. Graphical abstract Glucose is loaded into the pores of mesoporous silica nanoparticles (MSNs). MnO 2 nanosheets are assembled on MSNs through electrostatic interactions. Glutathione (GSH) can reduce the nanosheets, and this results in the release of glucose which is quantified by using a commercial glucose meter.

  12. Engineering of a novel Saccharomyces cerevisiae wine strain with a respiratory phenotype at high external glucose concentrations.

    Science.gov (United States)

    Henricsson, C; de Jesus Ferreira, M C; Hedfalk, K; Elbing, K; Larsson, C; Bill, R M; Norbeck, J; Hohmann, S; Gustafsson, L

    2005-10-01

    The recently described respiratory strain Saccharomyces cerevisiae KOY.TM6*P is, to our knowledge, the only reported strain of S. cerevisiae which completely redirects the flux of glucose from ethanol fermentation to respiration, even at high external glucose concentrations (27). In the KOY.TM6*P strain, portions of the genes encoding the predominant hexose transporter proteins, Hxt1 and Hxt7, were fused within the regions encoding transmembrane (TM) domain 6. The resulting chimeric gene, TM6*, encoded a chimera composed of the amino-terminal half of Hxt1 and the carboxy-terminal half of Hxt7. It was subsequently integrated into the genome of an hxt null strain. In this study, we have demonstrated the transferability of this respiratory phenotype to the V5 hxt1-7Delta strain, a derivative of a strain used in enology. We also show by using this mutant that it is not necessary to transform a complete hxt null strain with the TM6* construct to obtain a non-ethanol-producing phenotype. The resulting V5.TM6*P strain, obtained by transformation of the V5 hxt1-7Delta strain with the TM6* chimeric gene, produced only minor amounts of ethanol when cultured on external glucose concentrations as high as 5%. Despite the fact that glucose flux was reduced to 30% in the V5.TM6*P strain compared with that of its parental strain, the V5.TM6*P strain produced biomass at a specific rate as high as 85% that of the V5 wild-type strain. Even more relevant for the potential use of such a strain for the production of heterologous proteins and also of low-alcohol beverages is the observation that the biomass yield increased 50% with the mutant compared to its parental strain.

  13. Real-time monitoring of sucrose, sorbitol, d-glucose and d-fructose concentration by electromagnetic sensing.

    Science.gov (United States)

    Harnsoongnoen, Supakorn; Wanthong, Anuwat

    2017-10-01

    Magnetic sensing at microwave frequencies for real-time monitoring of sucrose, sorbitol, d-glucose and d-fructose concentrations is reported. The sensing element was designed based on a coplanar waveguide (CPW) loaded with a split ring resonator (SRR), which was fabricated on a DiClad 880 substrate with a thickness of 1.6mm and relative permittivity (ε r ) of 2.2. The magnetic sensor was connected to a Vector Network Analyzer (VNA) and the electromagnetic interaction between the samples and sensor was analyzed. The magnitude of the transmission coefficient (S 21 ) was used as an indicator to detect the solution sample concentrations ranging from 0.04 to 0.20g/ml. The experimental results confirmed that the developed system using microwaves for the real-time monitoring of sucrose, sorbitol, d-glucose and d-fructose concentrations gave unique results for each solution type and concentration. Moreover, the proposed sensor has a wide dynamic range, high linearity, fast operation and low-cost. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Childhood cardiorespiratory fitness, muscular fitness and adult measures of glucose homeostasis.

    Science.gov (United States)

    Fraser, Brooklyn J; Blizzard, Leigh; Schmidt, Michael D; Juonala, Markus; Dwyer, Terence; Venn, Alison J; Magnussen, Costan G

    2018-02-14

    To assess whether childhood cardiorespiratory fitness (CRF) and muscular fitness phenotypes (strength, power, endurance) predict adult glucose homeostasis measures. Prospective longitudinal study. Study examining participants who had physical fitness measured in childhood (aged 7-15 years) and who attended follow-up clinics approximately 20 years later and provided a fasting blood sample which was tested for glucose and insulin. Physical fitness measurements included muscular strength (right and left grip, shoulder flexion, shoulder and leg extension), power (standing long jump distance) and endurance (number of push-ups in 30s), and CRF (1.6km run duration). In adulthood, fasting glucose and insulin levels were used to derive glucose homeostasis measures of insulin resistance (HOMA2-IR) and beta cell function (HOMA2-β). A standard deviation increase in childhood CRF or muscular strength (males) was associated with fasting glucose (CRF: β=-0.06mmol/L), fasting insulin (CRF: β=-0.73mU/L; strength: β=-0.40mU/L), HOMA2-IR (CRF: β=-0.06; strength: β=-0.05) and HOMA2-β (CRF: β=-3.06%; strength: β=-2.62%) in adulthood, independent of the alternative fitness phenotype (all p0.06). CRF and muscular fitness in childhood were inversely associated with measures of fasting insulin, insulin resistance and beta cell function in adulthood. Childhood CRF and muscular fitness could both be potential independent targets for strategies to help reduce the development of adverse glucose homeostasis. Copyright © 2018 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  15. Glucose intolerance and the amount of visceral adipose tissue contribute to an increase in circulating triglyceride concentrations in Caucasian obese females.

    Science.gov (United States)

    Berings, Margot; Wehlou, Charline; Verrijken, An; Deschepper, Ellen; Mertens, Ilse; Kaufman, Jean-Marc; Van Gaal, Luc F; Ouwens, D Margriet; Ruige, Johannes B

    2012-01-01

    Lipotoxicity is a risk factor for developing obesity-related metabolic complications, including non-alcoholic fatty liver disease, type 2 diabetes (DM2), cardiovascular disease and stroke. Yet, the mechanisms underlying the development of lipotoxicity itself remain poorly understood. Here, we investigated whether glucose intolerance aggravates lipotoxicity by evaluating the association between triglyceride (TG) concentrations and glucose tolerance status in a cross-sectional study on obese Caucasian women at risk for DM2. 913 obese females unknown to have diabetes were recruited (mean age: 41.2 ± SD 12.3; median BMI: 36.2, IQR 32.9-40.2). Visceral (VAT) and subcutaneous abdominal adipose tissue volumes were quantified with computed tomography. Glucose, insulin, and triglyceride concentrations were determined in fasting state and following a 75 gram oral glucose tolerance test. Based on fasting and 2 h post-load glucose levels, 27% of the women had impaired glucose tolerance (IGT), and 8% had newly diagnosed DM2. Fasting TG concentrations were similar between the IGT- and DM2-groups, and increased as compared to women with normal glucose tolerance (NGT). Even when adjusting for age, hip circumference and VAT, fasting TG concentrations remained elevated as compared to NGT. Mixed modelling analysis of post-load responses showed that TG concentrations declined more slowly in the DM2-group as compared to IGT and NGT. However, when adjusting for VAT the difference in decline between the glucose tolerance groups disappeared. Glucose intolerance associates with elevated fasting TG concentrations in obese Caucasian women. We propose that glucose intolerance and increased VAT reduce lipid disposal mechanisms and may accelerate lipotoxicity.

  16. Glucose intolerance and the amount of visceral adipose tissue contribute to an increase in circulating triglyceride concentrations in Caucasian obese females.

    Directory of Open Access Journals (Sweden)

    Margot Berings

    Full Text Available CONTEXT: Lipotoxicity is a risk factor for developing obesity-related metabolic complications, including non-alcoholic fatty liver disease, type 2 diabetes (DM2, cardiovascular disease and stroke. Yet, the mechanisms underlying the development of lipotoxicity itself remain poorly understood. Here, we investigated whether glucose intolerance aggravates lipotoxicity by evaluating the association between triglyceride (TG concentrations and glucose tolerance status in a cross-sectional study on obese Caucasian women at risk for DM2. METHODS: 913 obese females unknown to have diabetes were recruited (mean age: 41.2 ± SD 12.3; median BMI: 36.2, IQR 32.9-40.2. Visceral (VAT and subcutaneous abdominal adipose tissue volumes were quantified with computed tomography. Glucose, insulin, and triglyceride concentrations were determined in fasting state and following a 75 gram oral glucose tolerance test. RESULTS: Based on fasting and 2 h post-load glucose levels, 27% of the women had impaired glucose tolerance (IGT, and 8% had newly diagnosed DM2. Fasting TG concentrations were similar between the IGT- and DM2-groups, and increased as compared to women with normal glucose tolerance (NGT. Even when adjusting for age, hip circumference and VAT, fasting TG concentrations remained elevated as compared to NGT. Mixed modelling analysis of post-load responses showed that TG concentrations declined more slowly in the DM2-group as compared to IGT and NGT. However, when adjusting for VAT the difference in decline between the glucose tolerance groups disappeared. CONCLUSIONS: Glucose intolerance associates with elevated fasting TG concentrations in obese Caucasian women. We propose that glucose intolerance and increased VAT reduce lipid disposal mechanisms and may accelerate lipotoxicity.

  17. Six and 12 Weeks of Caloric Restriction Increases β Cell Function and Lowers Fasting and Postprandial Glucose Concentrations in People with Type 2 Diabetes123

    Science.gov (United States)

    Sathananthan, Matheni; Shah, Meera; Edens, Kim L; Grothe, Karen B; Piccinini, Francesca; Farrugia, Luca P; Micheletto, Francesco; Man, Chiara Dalla; Cobelli, Claudio; Rizza, Robert A; Camilleri, Michael; Vella, Adrian

    2015-01-01

    Background: Caloric restriction alone has been shown to improve insulin action and fasting glucose metabolism; however, the mechanism by which this occurs remains uncertain. Objective: We sought to quantify the effect of caloric restriction on β cell function and glucose metabolism in people with type 2 diabetes. Methods: Nine subjects (2 men, 7 women) with type 2 diabetes [BMI (in kg/m2): 40.6 ± 1.4; age: 58 ± 3 y; glycated hemoglobin: 6.9% ± 0.2%] were studied using a triple-tracer mixed meal after withdrawal of oral diabetes therapy. The oral minimal model was used to measure β cell function. Caloric restriction limited subjects to a pureed diet (restriction. Results: Fasting glucose concentrations decreased significantly from baseline after 6 wk of caloric restriction with no further reduction after a further 6 wk of caloric restriction (9.8 ± 1.3, 5.9 ± 0.2, and 6.2 ± 0.3 mmol/L at baseline and after 6 and 12 wk of caloric restriction, respectively; P = 0.01) because of decreased fasting endogenous glucose production (EGP: 20.4 ± 1.1, 16.2 ± 0.8, and 17.4 ± 1.1 μmol · kg−1 · min−1 at baseline and after 6 and 12 wk of caloric restriction, respectively; P = 0.03). These changes were accompanied by an improvement in β cell function measured by the disposition index (189 ± 51, 436 ± 68, and 449 ± 67 10−14 dL · kg−1 · min−2 · pmol−1 at baseline and after 6 and 12 wk of caloric restriction, respectively; P = 0.01). Conclusions: Six weeks of caloric restriction lowers fasting glucose and EGP with accompanying improvements in β cell function in people with type 2 diabetes. An additional 6 wk of caloric restriction maintained the improvement in glucose metabolism. This trial was registered at clinicaltrials.gov as NCT01094054. PMID:26246321

  18. Neuroscience of glucose homeostasis

    NARCIS (Netherlands)

    La Fleur, S E; Fliers, E; Kalsbeek, A

    2014-01-01

    Plasma glucose concentrations are homeostatically regulated and maintained within strict boundaries. Several mechanisms are in place to increase glucose output when glucose levels in the circulation drop as a result of glucose utilization, or to decrease glucose output and increase tissue glucose

  19. Influence of partial pressure of oxygen in blood samples on measurement performance in glucose-oxidase-based systems for self-monitoring of blood glucose.

    Science.gov (United States)

    Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Haug, Cornelia; Freckmann, Guido

    2013-11-01

    Partial pressure of oxygen (pO2) in blood samples can affect blood glucose (BG) measurements, particularly in systems that employ the glucose oxidase (GOx) enzyme reaction on test strips. In this study, we assessed the impact of different pO2 values on the performance of five GOx systems and one glucose dehydrogenase (GDH) system. Two of the GOx systems are labeled by the manufacturers to be sensitive to increased blood oxygen content, while the other three GOx systems are not. Aliquots of 20 venous samples were adjusted to the following pO2 values: oxygen sensitive. © 2013 Diabetes Technology Society.

  20. The effect of 3-bromopyruvate on human colorectal cancer cells is dependent on glucose concentration but not hexokinase II expression.

    Science.gov (United States)

    Ho, Nelson; Morrison, Jodi; Silva, Andreza; Coomber, Brenda L

    2016-01-06

    Cancer cells heavily rely on the glycolytic pathway regardless of oxygen tension. Hexokinase II (HKII) catalyses the first irreversible step of glycolysis and is often overexpressed in cancer cells. 3-Bromopyruvate (3BP) has been shown to primarily target HKII, and is a promising anti-cancer compound capable of altering critical metabolic pathways in cancer cells. Abnormal vasculature within tumours leads to heterogeneous microenvironments, including glucose availability, which may affect drug sensitivity. The aim of the present study was to elucidate the mechanisms by which 3BP acts on colorectal cancer (CRC) cells with focus on the HKII/Akt signalling axis. High HKII-expressing cell lines were more sensitive to 3BP than low HKII-expressing cells. 3BP-induced rapid Akt phosphorylation at site Thr-308 and cell death via both apoptotic and necrotic mechanisms. Cells grown under lower glucose concentrations showed greater resistance towards 3BP. Cells with HKII knockdown showed no changes in 3BP sensitivity, suggesting the effects of 3BP are independent of HKII expression. These results emphasize the importance of the tumour microenvironment and glucose availability when considering therapeutic approaches involving metabolic modulation. © 2016 Authors.

  1. Accuracy evaluation of contour next compared with five blood glucose monitoring systems across a wide range of blood glucose concentrations occurring in a clinical research setting.

    Science.gov (United States)

    Klaff, Leslie J; Brazg, Ronald; Hughes, Kristen; Tideman, Ann M; Schachner, Holly C; Stenger, Patricia; Pardo, Scott; Dunne, Nancy; Parkes, Joan Lee

    2015-01-01

    This study evaluated the accuracy of Contour(®) Next (CN; Bayer HealthCare LLC, Diabetes Care, Whippany, NJ) compared with five blood glucose monitoring systems (BGMSs) across a wide range of clinically occurring blood glucose levels. Subjects (n=146) were ≥ 18 years and had type 1 or type 2 diabetes. Subjects' glucose levels were safely lowered or raised to provide a wide range of glucose values. Capillary blood samples were tested on six BGMSs and a YSI glucose analyzer (YSI Life Sciences, Inc., Yellow Springs, OH) as the reference. Extreme glucose values were achieved by glucose modification of the blood sample. System accuracy was assessed by mean absolute difference (MAD) and mean absolute relative difference (MARD) across several glucose ranges, with glucose range (Abbott Diabetes Care, Inc., Alameda, CA), 2.77 mg/dL; OneTouch(®) Ultra(®) 2 (LifeScan, Inc., Milpitas, CA), 10.20 mg/dL; OneTouch(®) Verio(®) Pro (LifeScan, Inc.), 4.53 mg/dL; and Truetrack(®) (Nipro Diagnostics, Inc., Fort Lauderdale, FL), 11.08 mg/dL. The lowest MAD in the low glucose range, from CN, was statistically significantly lower than those of the other BGMSs with the exception of the FSL. CN also had a statistically significantly lower MARD than all other BGMSs in the low glucose range. In the overall glucose range (21-496 mg/dL), CN yielded the lowest MAD and MARD values, which were statistically significantly lower in comparison with the other BGMSs. When compared with other BGMSs, CN demonstrated the lowest mean deviation from the reference value (by MAD and MARD) across multiple glucose ranges.

  2. One-hour and two-hour postload plasma glucose concentrations are comparable predictors of type 2 diabetes mellitus in Southwestern Native Americans.

    Science.gov (United States)

    Paddock, Ethan; Hohenadel, Maximilian G; Piaggi, Paolo; Vijayakumar, Pavithra; Hanson, Robert L; Knowler, William C; Krakoff, Jonathan; Chang, Douglas C

    2017-09-01

    Elevated 2-h plasma glucose concentration (2 h-PG) during a 75 g OGTT predict the development of type 2 diabetes mellitus. However, 1-h plasma glucose concentration (1 h-PG) is associated with insulin secretion and may be a better predictor of type 2 diabetes. We aimed to investigate the association between 1 h-PG and 2 h-PG using gold standard methods for measuring insulin secretion and action. We also compared 1 h-PG and 2 h-PG as predictors of type 2 diabetes mellitus. This analysis included adult volunteers without diabetes, predominantly Native Americans of Southwestern heritage, who were involved in a longitudinal epidemiological study from 1965 to 2007, with a baseline OGTT that included measurement of 1 h-PG. Group 1 (n = 716) underwent an IVGTT and hyperinsulinaemic-euglycaemic clamp for measurement of acute insulin response (AIR) and insulin-stimulated glucose disposal (M), respectively. Some members of Group 1 (n = 490 of 716) and members of a second, larger, group (Group 2; n = 1946) were followed-up to assess the development of type 2 diabetes (median 9.0 and 12.8 years follow-up, respectively). Compared with 2 h-PG (r = -0.281), 1 h-PG (r = -0.384) was more closely associated with AIR, whereas, compared with 1 h-PG (r = -0.340), 2 h-PG (r = -0.408) was more closely associated with M. Measures of 1 h-PG and 2 h-PG had similar abilities to predict type 2 diabetes, which did not change when both were included in the model. A 1 h-PG cut-off of 9.3 mmol/l provided similar levels of sensitivity and specificity as a 2 h-PG cut-off of 7.8 mmol/l; the latter is used to define impaired glucose tolerance, a recognised predictor of type 2 diabetes mellitus. The 1 h-PG was associated with important physiological predictors of type 2 diabetes and was as effective as 2 h-PG for predicting type 2 diabetes mellitus. The 1 h-PG is, therefore, an alternative method of identifying individuals with an elevated risk of type 2 diabetes

  3. Nondestructive measurement for radionuclide concentration distribution in soil column

    International Nuclear Information System (INIS)

    Ogawa, Hiromichi; Ohnuki, Toshihiko; Yamamoto, Tadatoshi; Wadachi, Yoshiki

    1985-01-01

    A nondestructive method has been studied for determining the concentration of radionuclide (Cs-137) distributed in a soil column. The concentration distribution was calculated from the counting rate distribution using the efficiency matrix of a detector. The concentration distribution obtained by this method, with measuring efficiencies of theoretical calculation, coincides well with that obtained by the destructive sampling method. This method is, therefore, found to be effective for the measurement of one dimensional concentration distribution. The measuring limit of this method is affected not only by the radionuclide concentration but also by the shape of concentration distribution in a soil column and also by the way it is divided into concentration blocks. It is found that, the radioactive concentration up to 2.6 x 10 -4 μCi/g (9.62 Bq/g), and also the distribution up to where the concentration reduces to half at every 1 cm of depth, can be measured by this system. The concentration blocks can be divided into 1 cm of thickness as a minimum value. (author)

  4. Hierarchical clustering of Alzheimer and 'normal' brains using elemental concentrations and glucose metabolism determined by PIXE, INAA and PET

    International Nuclear Information System (INIS)

    Cutts, D.A.; Spyrou, N.M.

    2001-01-01

    Brain tissue samples, obtained from the Alzheimer Disease Brain Bank, Institute of Psychiatry, London, were taken from both left and right hemispheres of three regions of the cerebrum, namely the frontal, parietal and occipital lobes for both Alzheimer and 'normal' subjects. Trace element concentrations in the frontal lobe were determined for twenty six Alzheimer (15 male, 11 female) and twenty six 'normal' (8 male, 18 female) brain tissue samples. In the parietal lobe ten Alzheimer (2 male, 8 female) and ten 'normal' (8 male, 2 female) samples were taken along with ten Alzheimer (4 male, 6 female) and ten 'normal' (6 male, 4 female) from the occipital lobe. For the frontal lobe trace element concentrations were determined using proton induced X-ray emission (PIXE) analysis while in parietal and occipital regions instrumental neutron activation analysis (INAA) was used. Additionally eighteen Alzheimer (9 male, 9 female) and eighteen age matched 'normal' (8 male, 10 female) living subjects were examined using positron emission tomography (PET) in order to determine regional cerebral metabolic rates of glucose (rCMRGlu). The rCMRGlu of 36 regions of the brain was investigated including frontal, occipital and parietal lobes as in the trace element study. Hierarchical cluster analysis was applied to the trace element and glucose metabolism data to discover which variables in the resulting dendrograms displayed the most significant separation between Alzheimer and 'normal' subjects. (author)

  5. Evaluation of 12 blood glucose monitoring systems for self-testing: system accuracy and measurement reproducibility.

    Science.gov (United States)

    Freckmann, Guido; Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Link, Manuela; Haug, Cornelia

    2014-02-01

    Systems for self-monitoring of blood glucose (SMBG) have to provide accurate and reproducible blood glucose (BG) values in order to ensure adequate therapeutic decisions by people with diabetes. Twelve SMBG systems were compared in a standardized manner under controlled laboratory conditions: nine systems were available on the German market and were purchased from a local pharmacy, and three systems were obtained from the manufacturer (two systems were available on the U.S. market, and one system was not yet introduced to the German market). System accuracy was evaluated following DIN EN ISO (International Organization for Standardization) 15197:2003. In addition, measurement reproducibility was assessed following a modified TNO (Netherlands Organization for Applied Scientific Research) procedure. Comparison measurements were performed with either the glucose oxidase method (YSI 2300 STAT Plus™ glucose analyzer; YSI Life Sciences, Yellow Springs, OH) or the hexokinase method (cobas(®) c111; Roche Diagnostics GmbH, Mannheim, Germany) according to the manufacturer's measurement procedure. The 12 evaluated systems showed between 71.5% and 100% of the measurement results within the required system accuracy limits. Ten systems fulfilled with the evaluated test strip lot minimum accuracy requirements specified by DIN EN ISO 15197:2003. In addition, accuracy limits of the recently published revision ISO 15197:2013 were applied and showed between 54.5% and 100% of the systems' measurement results within the required accuracy limits. Regarding measurement reproducibility, each of the 12 tested systems met the applied performance criteria. In summary, 83% of the systems fulfilled with the evaluated test strip lot minimum system accuracy requirements of DIN EN ISO 15197:2003. Each of the tested systems showed acceptable measurement reproducibility. In order to ensure sufficient measurement quality of each distributed test strip lot, regular evaluations are required.

  6. Common variants related to serum uric acid concentrations are associated with glucose metabolism and insulin secretion in a Chinese population.

    Directory of Open Access Journals (Sweden)

    Xue Sun

    Full Text Available Elevated serum uric acid concentration is an independent risk factor and predictor of type 2 diabetes (T2D. Whether the uric acid-associated genes have an impact on T2D remains unclear. We aimed to investigate the effects of the uric acid-associated genes on the risk of T2D as well as glucose metabolism and insulin secretion.We recruited 2,199 normal glucose tolerance subjects from the Shanghai Diabetes Study I and II and 2,999 T2D patients from the inpatient database of Shanghai Diabetes Institute. Fifteen single nucleotide polymorphisms (SNPs mapped in or near 11 loci (PDZK1, GCKR, LRP2, SLC2A9, ABCG2, LRRC16A, SLC17A1, SLC17A3, SLC22A11, SLC22A12 and SF1 were genotyped and serum biochemical parameters related to uric acid and T2D were determined.SF1 rs606458 showed strong association to T2D in both males and females (p = 0.034 and 0.0008. In the males, LRRC16A was associated with 2-h insulin and insulin secretion (p = 0.009 and 0.009. SLC22A11 was correlated with HOMA-B and insulin secretion (p = 0.048 and 0.029. SLC2A9 rs3775948 was associated with 2-h glucose (p = 0.043. In the females, LRP2 rs2544390 and rs1333049 showed correlations with fasting insulin, HOMA-IR and insulin secretion (p = 0.028, 0.033 and 0.052 and p = 0.034, 0.047 and 0.038, respectively. SLC2A9 rs11722228 was correlated with 2-h glucose, 2-h insulin and insulin secretion (p = 0.024, 0.049 and 0.049, respectively.Our results indicated that the uric acid-associated genes have an impact on the risk of T2D, glucose metabolism and insulin secretion in a Chinese population.

  7. Trichosanthes cucumerina extracts enhance glucose uptake and regulate adiponectin and leptin concentrations in 3T3-L1 adipocytes model

    Directory of Open Access Journals (Sweden)

    Sassi, A.,

    2017-10-01

    Full Text Available Trichosanthes cucumerina (Cucurbitaceae commonly known as Snake gourd or Labu Ular is considered the largest genre in the Cucurbitaceae family and is mainly found in the southeast areas of Asia. It has been used in Ayurvedic medicine as a treatment for certain diseases such as Diabetes mellitus, but these acclaims lack scientific-based evidence. In this study, water and ethanol extracts of three parts of Trichosanthes cucumerina namely; whole vegetable, peels, and seeds, were assessed for toxicity through a cell viability assay using 3T3-L1 pre-adipocytes model which revealed a maximum toleration concentration of 0.063 mg/mL. The extracts were further tested on adipocytes’ differentiation and positively showed a stimulation of lipid droplets formation during adipogenesis and significantly (p<0.001 increased glycerol release levels (75.34±3.69 μg/ml during adipolysis. The extracts also significantly (p<0.001 promoted the uptake of glucose into the cells (2636.22±91.33 Bq in an action similar to that of insulin. Similar results were observed during ELISA assay with a significant increase (p<0.001 in adiponectin concentrations (3593.1±225.25 ng/mL and a decrease in leptin concentrations (23870±5066.07 pg/mL. The present study results indicate a beneficial effect of Trichosanthes cucumerina extracts on adipogenesis, adipolysis and glucose uptake, in addition to a regulation of adiponectin and leptin concentrations in 3T3-L1 adipocytes which can be of clinical importance in energy regulation which is a key factor in treating diabetes, obesity, and metabolic syndrome.

  8. Heterotrophic and mixotrophic growth of Micractinium pusillum Fresenius in the presence of acetate and glucose: effect of light and acetate gradient concentration.

    Science.gov (United States)

    Bouarab, L; Dauta, A; Loudiki, M

    2004-06-01

    The main objective of this study was to determine the importance of secondary mechanism of organic carbon utilization (mixotrophic and heterotrophic modes) in addition to CO2 fixation (photoautotrophic mode) in the green alga, Micractinium pusillum Fresenius (chlorophyta), isolated from a waste stabilization pond. The growth was studied in the presence of acetate and glucose. The incorporation rate of 14C- acetate was measured in the light and in the dark at different concentrations. Finally, in order to underline the role of photosynthesis and respiration processes in the acetate assimilation, the effect of two specific metabolic inhibitors, a specific inhibitor of photosystem II (DCMU) and an uncoupler respiratory (DNP), has been studied. The obtained results showed that M. pusillum grows in the presence of organic substrates, i.e., glucose and acetate, in the light (mixotrophic growth) as well as in the dark (Heterotrophic growth). The growth was much more important in the light than in the dark and more in the presence of glucose than of acetate. In the light, the presence of acetate led to a variation of growth parameters mumax, iotaopt, and beta. The effect of acetate gradient on the growth of the microalga was severe as soon as its concentration in the medium was higher. The acetate uptake followed a Michaelis-Menten kinetic in the light as well as in the dark. The capacity of assimilation was slightly higher in the dark. The utilization of DNP and DCMU indicates that acetate incorporation is an active process depending on both anabolic (photosynthesis) and catabolic (respiration) metabolisms, corroborating the model of the Michaelis-Menten kinetic.

  9. MicroRNA Expression Varies according to Glucose Tolerance, Measurement Platform, and Biological Source

    Directory of Open Access Journals (Sweden)

    S. Dias

    2017-01-01

    Full Text Available Dysregulated microRNA (miRNA expression is observed during type 2 diabetes (T2D, although the consistency of miRNA expression across measurement platform and biological source is uncertain. Here we report miRNA profiling in the whole blood and serum of South African women with different levels of glucose tolerance, using next generation sequencing (NGS and quantitative real time PCR (qRT-PCR. Whole blood-derived miRNAs from women with newly diagnosed T2D (n=4, impaired glucose tolerance (IGT (n=4, and normal glucose tolerance (NGT (n=4 were subjected to NGS, whereafter transcript levels of selected miRNAs were quantified in the whole blood and serum of these women using qRT-PCR. Of the five significantly differentially expressed miRNAs identified by NGS, only the directional increase of miR-27b in women with IGT compared to NGT was confirmed in whole blood and serum, using qRT-PCR. Functional enrichment of miR-27b gene targets identified biological pathways associated with glucose transport and insulin regulation. In conclusion, this study showed poor correlation in miRNA expression profiled using NGS and qRT-PCR and in whole blood and serum. The consistent increased expression of miR-27b in women with IGT compared to NGT across measurement platform and biological source holds potential as a biomarker for risk stratification in our population.

  10. Measured and calculated NO2 concentrations in Amsterdam in 2008

    International Nuclear Information System (INIS)

    Wesseling, J.P.; Nguyen, P.L.; Van der Zee, S.

    2010-08-01

    Calculations using the Dutch standard calculation method for air quality in urban streets performed for 38 streets in Amsterdam in 2008 yield, on average, lower Nitrogen dioxide concentrations than measurements at those locations. This follows from research by the RIVM and the Public Health Service of Amsterdam (GGD Amsterdam). The average difference between measured and calculated concentrations is 11 %. At measuring locations of the National Air Quality Measuring Network in the Netherlands no significant underestimation of concentrations by the model is observed. The research was performed by the Dutch ministry of Housing, Spatial Planning en the Environment (VROM). The air quality in the streets that were investigated is mainly determined by emissions from local traffic. The measurements have been performed during thirteen periods of four weeks each, using so called 'Palmes' diffusion tubes. These measurements have been calibrated using the European reference method that is operational in the permanent measuring stations of the GGD Amsterdam. The calculations were performed using the geometry of the roads and information of the traffic at the measuring locations. Part of the differences can be explained, as some locations are not within the scope of the model. In these situations the model is known to perform slightly less. Apart from local traffic, other sources, like shipping, also contribute to the NO2 background concentrations in streets in Amsterdam. Sources that have only globally been included in the calculation of this background concentration may influence concentrations at specific locations. Further studies on this subject will be conducted in 2010. [nl

  11. Effects of Barium Concentration on Oropharyngeal Swallow Timing Measures

    OpenAIRE

    Stokely, Shauna L.; Molfenter, Sonja M.; Steele, Catriona M.

    2013-01-01

    Videofluoroscopy is commonly used for evaluating oropharyngeal swallowing but requires radiopaque contrast (typically barium). Prior studies suggest that some aspects of swallowing, including timing measures of oral and pharyngeal bolus transit, vary depending on barium concentration. The aim of our study was to identify timing differences in healthy swallowing between “thin” (40 % w/v concentration) and “ultrathin” (22 % w/v concentration) barium solutions. Twenty healthy adults (Ten women; ...

  12. Variation of pH-measurement in platelet concentrates

    NARCIS (Netherlands)

    van der Meer, P. F.; van Zanten, A. P.; Pietersz, R. N.; Reesink, H. W.

    2001-01-01

    To measure pH in platelet concentrates, blood gas analysers with different calibration principles may be used. In this study, variances observed in pH measurements with two types of blood gas analysers were investigated. pH was measured in crystalloid solutions (platelet additive solution (PAS-II),

  13. Liver kinetics of glucose analogs measured in pigs by PET: importance of dual-input blood sampling

    DEFF Research Database (Denmark)

    Munk, O L; Bass, L; Roelsgaard, K

    2001-01-01

    -input functions were very similar. CONCLUSION: Compartmental analysis of MG and FDG kinetics using dynamic PET data requires measurements of dual-input activity concentrations. Using the dual-input function, physiologically reasonable parameter estimates of K1, k2, and Vp were obtained, whereas the use......Metabolic processes studied by PET are quantified traditionally using compartmental models, which relate the time course of the tracer concentration in tissue to that in arterial blood. For liver studies, the use of arterial input may, however, cause systematic errors to the estimated kinetic...... parameters, because of ignorance of the dual blood supply from the hepatic artery and the portal vein to the liver. METHODS: Six pigs underwent PET after [15O]carbon monoxide inhalation, 3-O-[11C]methylglucose (MG) injection, and [18F]FDG injection. For the glucose scans, PET data were acquired for 90 min...

  14. Effects of barium concentration on oropharyngeal swallow timing measures.

    Science.gov (United States)

    Stokely, Shauna L; Molfenter, Sonja M; Steele, Catriona M

    2014-02-01

    Videofluoroscopy is commonly used for evaluating oropharyngeal swallowing but requires radiopaque contrast (typically barium). Prior studies suggest that some aspects of swallowing, including timing measures of oral and pharyngeal bolus transit, vary depending on barium concentration. The aim of our study was to identify timing differences in healthy swallowing between "thin" (40 % w/v concentration) and "ultrathin" (22 % w/v concentration) barium solutions. Twenty healthy adults (Ten women; mean age = 31 years) each performed a series of three noncued 5-ml swallows each of ultrathin and thin liquid barium solutions in videofluoroscopy. Timing measures were compared between barium concentrations using a mixed-model ANOVA. The measures of interest were stage transition duration, pharyngeal transit time, and duration of upper esophageal sphincter opening. Significant differences were observed in the timing measures of swallowing with respect to barium concentration. In all cases, longer durations were seen with the higher barium concentration. Barium concentration influences timing parameters in healthy swallowing, even between ultrathin and thin concentrations. Clinicians need to understand and control for the impact of different barium stimuli on swallowing physiology.

  15. Low serum cartonectin/CTRP3 concentrations in newly diagnosed type 2 diabetes mellitus: in vivo regulation of cartonectin by glucose.

    Directory of Open Access Journals (Sweden)

    Bo Ban

    Full Text Available OBJECTIVES: Cartonectin is a novel adipokine of the C1q complement/TNF-related protein (CTRP superfamily, with glucose lowering effects, anti-inflammatory and cardio-protective properties. We sought to investigate circulating cartonectin concentrations in subjects with type 2 diabetes mellitus (T2DM as well as age and BMI matched control subjects. We also examined the effects of a 2 hour 75 g oral glucose tolerance test (OGTT on serum cartonectin concentrations in T2DM subjects. DESIGN: Cross-sectional study [newly diagnosed (first discovery, not on any treatments T2DM (n = 47 and control (n = 63 subjects]. Serum cartonectin was measured by ELISA. RESULTS: Serum cartonectin concentrations were significantly lower in patients with T2DM compared to controls (P0.05. There were no significant correlations in T2DM subjects (n = 47. In control subjects (n = 63, serum cartonectin was significantly negatively correlated with CRP, and significantly positively correlated with insulin, HOMA-IR and leptin. However, when subjected to multiple regression analysis, none of these variables were predictive of serum cartonectin (P>0.05. Finally, serum cartonectin concentrations were significantly lower in T2DM subjects after a 2 hour 75 g OGTT (P<0.01. CONCLUSIONS: Cartonectin may serve as a novel biomarker for the prediction and early diagnosis of T2DM patients. Furthermore, cartonectin and/or pharmacological agents that increase circulating cartonectin levels can represent a new therapeutic field in the treatment of T2DM patients. Further research is needed to clarify these points.

  16. Aquatic respiration rate measurements at low oxygen concentrations.

    Directory of Open Access Journals (Sweden)

    Moritz Holtappels

    Full Text Available Despite its huge ecological importance, microbial oxygen respiration in pelagic waters is little studied, primarily due to methodological difficulties. Respiration measurements are challenging because of the required high resolution of oxygen concentration measurements. Recent improvements in oxygen sensing techniques bear great potential to overcome these limitations. Here we compare 3 different methods to measure oxygen consumption rates at low oxygen concentrations, utilizing amperometric Clark type sensors (STOX, optical sensors (optodes, and mass spectrometry in combination with (18-18O2 labeling. Oxygen concentrations and consumption rates agreed well between the different methods when applied in the same experimental setting. Oxygen consumption rates between 30 and 400 nmol L(-1 h(-1 were measured with high precision and relative standard errors of less than 3%. Rate detection limits in the range of 1 nmol L(-1 h(-1 were suitable for rate determinations in open ocean water and were lowest at the lowest applied O2 concentration.

  17. Direct concentration and viability measurement of yeast in corn mash using a novel imaging cytometry method.

    Science.gov (United States)

    Chan, Leo L; Lyettefi, Emily J; Pirani, Alnoor; Smith, Tim; Qiu, Jean; Lin, Bo

    2011-08-01

    Worldwide awareness of fossil-fuel depletion and global warming has been increasing over the last 30 years. Numerous countries, including the USA and Brazil, have introduced large-scale industrial fermentation facilities for bioethanol, biobutanol, or biodiesel production. Most of these biofuel facilities perform fermentation using standard baker's yeasts that ferment sugar present in corn mash, sugar cane, or other glucose media. In research and development in the biofuel industry, selection of yeast strains (for higher ethanol tolerance) and fermentation conditions (yeast concentration, temperature, pH, nutrients, etc.) can be studied to optimize fermentation performance. Yeast viability measurement is needed to identify higher ethanol-tolerant yeast strains, which may prolong the fermentation cycle and increase biofuel output. In addition, yeast concentration may be optimized to improve fermentation performance. Therefore, it is important to develop a simple method for concentration and viability measurement of fermenting yeast. In this work, we demonstrate an imaging cytometry method for concentration and viability measurements of yeast in corn mash directly from operating fermenters. It employs an automated cell counter, a dilution buffer, and staining solution from Nexcelom Bioscience to perform enumeration. The proposed method enables specific fluorescence detection of viable and nonviable yeasts, which can generate precise results for concentration and viability of yeast in corn mash. This method can provide an essential tool for research and development in the biofuel industry and may be incorporated into manufacturing to monitor yeast concentration and viability efficiently during the fermentation process.

  18. Measurement of radon activity concentrations in air of Tuzla city

    International Nuclear Information System (INIS)

    Adrovic, F.; Fazlic, R.; Tresnjo, Z.

    2004-01-01

    The survey was conducted over one year in the area of Tuzla city and its surrounding. At the measuring locations there were registered Daily and seasonal variations in outdoor radon concentration were observed, with average values lying within the region of 9 - 30 Bq/m 3 . The results of the measurements will be included in the concentration map of radon activity in Bosnia and Herzegovina, which is under preparation. (P.A.)

  19. Femtosecond laser micromachining of compound parabolic concentrator fiber tipped glucose sensors

    DEFF Research Database (Denmark)

    Hassan, Hafeez Ul; Lacraz, Amédée; Kalli, Kyriacos

    2017-01-01

    We report on highly accurate femtosecond (fs) laser micromachining of a compound parabolic concentrator (CPC) fiber tip on a polymer optical fiber (POF). The accuracy is reflected in an unprecedented correspondence between the numerically predicted and experimentally found improvement in fluoresc...

  20. Comparison of Glucose Area Under the Curve Measured Using Minimally Invasive Interstitial Fluid Extraction Technology with Continuous Glucose Monitoring System in Diabetic Patients.

    Science.gov (United States)

    Uemura, Mei; Yano, Yutaka; Suzuki, Toshinari; Yasuma, Taro; Sato, Toshiyuki; Morimoto, Aya; Hosoya, Samiko; Suminaka, Chihiro; Nakajima, Hiromu; Gabazza, Esteban C; Takei, Yoshiyuki

    2017-08-01

    Continuous glucose monitoring (CGM) is reported to be a useful technique, but difficult or inconvenient for some patients and institutions. We are developing a glucose area under the curve (AUC) monitoring system without blood sampling using a minimally invasive interstitial fluid extraction technology (MIET). Here we evaluated the accuracy of interstitial fluid glucose (IG) AUC measured by MIET in patients with diabetes for an extended time interval and the potency of detecting hyperglycemia using CGM data as a reference. Thirty-eight inpatients with diabetes undergoing CGM were enrolled. MIET comprised a pretreatment step using a plastic microneedle array and glucose accumulation step with a hydrogel patch, which was placed on two sites from 9:00 AM to 5:00 PM or from 10:00 PM to 6:00 AM. IG AUC was calculated by accumulated glucose extracted by hydrogel patches using sodium ion as standard. A significant correlation was observed between the predicted AUC by MIET and CGM in daytime (r=0.76) and nighttime (r=0.82). The optimal cutoff for the IG AUC value of MIET to predict hyperglycemia over 200 mg/dL measured by CGM for 8 hours was 1,067.3 mg·hr/dL with 88.2% sensitivity and 81.5% specificity. We showed that 8-hour IG AUC levels using MIET were valuable in estimating the blood glucose AUC without blood sampling. The results also supported the concept of using this technique for evaluating glucose excursion and for screening hyperglycemia during 8 hours in patients with diabetes at any time of day. Copyright © 2017 Korean Diabetes Association

  1. Comparison of Glucose Area Under the Curve Measured Using Minimally Invasive Interstitial Fluid Extraction Technology with Continuous Glucose Monitoring System in Diabetic Patients

    Directory of Open Access Journals (Sweden)

    Mei Uemura

    2017-07-01

    Full Text Available BackgroundContinuous glucose monitoring (CGM is reported to be a useful technique, but difficult or inconvenient for some patients and institutions. We are developing a glucose area under the curve (AUC monitoring system without blood sampling using a minimally invasive interstitial fluid extraction technology (MIET. Here we evaluated the accuracy of interstitial fluid glucose (IG AUC measured by MIET in patients with diabetes for an extended time interval and the potency of detecting hyperglycemia using CGM data as a reference.MethodsThirty-eight inpatients with diabetes undergoing CGM were enrolled. MIET comprised a pretreatment step using a plastic microneedle array and glucose accumulation step with a hydrogel patch, which was placed on two sites from 9:00 AM to 5:00 PM or from 10:00 PM to 6:00 AM. IG AUC was calculated by accumulated glucose extracted by hydrogel patches using sodium ion as standard. ResultsA significant correlation was observed between the predicted AUC by MIET and CGM in daytime (r=0.76 and nighttime (r=0.82. The optimal cutoff for the IG AUC value of MIET to predict hyperglycemia over 200 mg/dL measured by CGM for 8 hours was 1,067.3 mg·hr/dL with 88.2% sensitivity and 81.5% specificity.ConclusionWe showed that 8-hour IG AUC levels using MIET were valuable in estimating the blood glucose AUC without blood sampling. The results also supported the concept of using this technique for evaluating glucose excursion and for screening hyperglycemia during 8 hours in patients with diabetes at any time of day.

  2. Measurements of indoor radon concentration in Libyan cities

    International Nuclear Information System (INIS)

    Elarabiy, S. F.; Khalifa, M.; Misrati, N.; Chahboune, N.; Ahmed, M.

    2012-12-01

    Studies confirm that the risk of exposure to indor radon is attributable to lung cancer worldwide. The relationship between radon exposure and cancer is a linear one which necessitates for need for measurements of indoor radon concentration. This paper presents the results of measurements of indoor radon in several libya cities using CR-39 plastic. The results showed that the average radon concentration in the cities of Tripoli, Al-harcha and Alrajaban were 48.8 Bg/m 3 , 51.4 Bg/m 3 and 55.5 Bg/m 3 respectively. The average indoor radon concentration in Libya is low comparing with other studies. (Author)

  3. Ablation of neurons expressing melanin-concentrating hormone (MCH) in adult mice improves glucose tolerance independent of MCH signaling.

    Science.gov (United States)

    Whiddon, Benjamin B; Palmiter, Richard D

    2013-01-30

    Melanin-concentrating hormone (MCH)-expressing neurons have been ascribed many roles based on studies of MCH-deficient mice. However, MCH neurons express other neurotransmitters, including GABA, nesfatin, and cocaine-amphetamine-regulated transcript. The importance of these other signaling molecules made by MCH neurons remains incompletely characterized. To determine the roles of MCH neurons in vivo, we targeted expression of the human diphtheria toxin receptor (DTR) to the gene for MCH (Pmch). Within 2 weeks of diphtheria toxin injection, heterozygous Pmch(DTR/+) mice lost 98% of their MCH neurons. These mice became lean but ate normally and were hyperactive, especially during a fast. They also responded abnormally to psychostimulants. For these phenotypes, ablation of MCH neurons recapitulated knock-out of MCH, so MCH appears to be the critical neuromodulator released by these neurons. In contrast, MCH-neuron-ablated mice showed improved glucose tolerance when compared with MCH-deficient mutant mice and wild-type mice. We conclude that MCH neurons regulate glucose tolerance through signaling molecules other than MCH.

  4. Workplace aerosol mass concentration measurement using optical particle counters.

    Science.gov (United States)

    Görner, Peter; Simon, Xavier; Bémer, Denis; Lidén, Göran

    2012-02-01

    Direct-reading aerosol measurement usually uses the optical properties of airborne particles to detect and measure particle concentration. In the case of occupational hygiene, mass concentration measurement is often required. Two aerosol monitoring methods are based on the principle of light scattering: optical particle counting (OPC) and photometry. The former analyses the light scattered by a single particle, the latter by a cloud of particles. Both methods need calibration to transform the quantity of scattered light detected into particle concentration. Photometers are simpler to use and can be directly calibrated to measure mass concentration. However, their response varies not only with aerosol concentration but also with particle size distribution, which frequently contributes to biased measurement. Optical particle counters directly measure the particle number concentration and particle size that allows assessment of the particle mass provided the particles are spherical and of known density. An integrating algorithm is used to calculate the mass concentration of any conventional health-related aerosol fraction. The concentrations calculated thus have been compared with simultaneous measurements by conventional gravimetric sampling to check the possibility of field OPC calibration with real workplace aerosols with a view to further monitoring particle mass concentration. Aerosol concentrations were measured in the food industry using the OPC GRIMM® 1.108 and the CIP 10-Inhalable and CIP 10-Respirable (ARELCO®) aerosol samplers while meat sausages were being brushed and coated with calcium carbonate. Previously, the original OPC inlet had been adapted to sample inhalable aerosol. A mixed aerosol of calcium carbonate and fungi spores was present in the workplace. The OPC particle-size distribution and an estimated average particle density of both aerosol components were used to calculate the mass concentration. The inhalable and respirable aerosol fractions

  5. Successful microsurgical lip replantation: Monitoring venous congestion by blood glucose measurements in the replanted lip

    OpenAIRE

    Kazufumi Tachi; Masanori Mori; Reiko Tsukuura; Rintaro Hirai

    2018-01-01

    Replantation of an amputated lip using microvascular anastomosis is the best option for restoration of the defect. However, the amputated region often lacks veins with appropriate diameters for microvascular anastomoses and typically necessitates both postoperative exsanguination using medicinal leeches and a blood transfusion. We present a case of the successful replantation of an avulsed lip in which postoperative congestion was evaluated objectively by measuring blood glucose levels in the...

  6. Noninvasive measurement of regional myocardial glucose metabolism by positron emission computed tomography

    International Nuclear Information System (INIS)

    Schelbert, H.R.; Phelps, M.E.

    While the results of regional myocardial glucose metabolism measurements using positron emission computed tomography ( 13 N-ammonia) are promising, their utility and value remains to be determined in man. If this technique can be applied to patients with acute myocardial ischemia or infarction it may permit delineation of regional myocardial segments with altered, yet still active metabolism. Further, it may become possible to evaluate the effects of interventions designed to salvage reversibly injured myocardium by this technique

  7. Validation of image cytometry for sperm concentration measurement

    DEFF Research Database (Denmark)

    Egeberg Palme, Dorte L.; Johannsen, Trine Holm; Petersen, Jørgen Holm

    2017-01-01

    Sperm concentration is an essential parameter in the diagnostic evaluation of men from infertile couples. It is usually determined by manual counting using a hemocytometer, and is therefore both laborious and subjective. We have earlier shown that a newly developed image cytometry (IC) method may...... be used to determine sperm concentration. Here we present a validation of the IC method by analysis of 4010 semen samples. There was high agreement between IC and manual counting at sperm concentrations above 3 mill/ml and in samples with concentrations above 12 mill/ml the two methods can be used...... a lower coefficient of variation than the manual method (5% vs 10%), indicating a better precision of the IC method. In conclusion, measurement of sperm concentration by IC can be used at concentrations above 3 mill/ml and seems more accurate and precise than manual counting, making it an attractive...

  8. Traceable measurements of the activity concentration in air

    CERN Document Server

    Paul, A; Forkel-Wirth, Doris; Müller, A; Marcos, A

    2002-01-01

    The nuclear reactions induced by high energetic protons in heavy targets such as UC/sub 2/ and ThC cause a particular, complex radiation protection task at facilities like ISOLDE: the measurement of a mixture of different isotopes of the radioactive noble gas radon and the radon progenies in air. The knowledge of their respective activity concentration is fundamental for exposure assessments. Due to the complex mixture of activity concentrations in air, its precise determination is quite difficult. Therefore, a new procedure for taking reference samples was developed and implemented for the traceable measurement of the activity concentration of radioactive ions (e.g., radon progenies) in air. This technique is combined by measuring alpha -particles with a multi-wire ionization chamber for the parallel on-line determination of the activity concentration of different radon isotopes. (10 refs).

  9. Intercomparison of different instruments for measuring radon concentration in air

    International Nuclear Information System (INIS)

    Shimo, Michikuni; Iida, Takao

    1990-01-01

    An intercomparison of different instruments for measurement of radon concentration was carried out. The instruments include an ionization chamber, the charcoal-trap method, a flow-type ionization chamber (pulse-counting method), a two-filter method, an electrostatic collection method and a passive integration radon monitor. All instruments except for the passive radon monitor have been calibrated independently. Measurements were performed over a concentration range from about 3.5 Bq·m -3 (in outdoor air) to 110 Bq·m -3 (in indoor air). The results obtained by these techniques, except the two-filter technique, are comparable. Radon daughter concentration measured using a filter-sampling method was about 52% of radon concentration. (author)

  10. Intercomparison of different instruments that measure radon concentration in air

    International Nuclear Information System (INIS)

    Shimo, M.; Iida, T.; Ikebe, Y.

    1987-01-01

    An intercomparison of different instruments for measurement of radon concentration was carried out. The instruments include an ionization chamber, the charcoal-trap technique, a flow-type ionization chamber (pulse-counting technique), a two-filter method, an electrostatic collection method and a passive integrating radon monitor. All instruments except for the passive radon monitor have been calibrated independently. Measurements were performed over a concentration range from about 3.5 Bq/m/sup 3/ (in outdoor air) to 110 Bq/m/sup 3/ (in indoor air). The results obtained from these techniques, except the two-filter technique, are comparable. Radon daughter concentration measured using a filter-sampling technique was about 52% of radon concentrations

  11. Traceable measurements of the activity concentration in air

    International Nuclear Information System (INIS)

    Paul, Annette; Honig, Anja; Forkel-Wirth, Doris; Mueller, Andre; Marcos, Alicia

    2002-01-01

    The nuclear reactions induced by high energetic protons in heavy targets such as UC 2 and ThC cause a particular, complex radiation protection task at facilities like ISOLDE: the measurement of a mixture of different isotopes of the radioactive noble gas radon and the radon progenies in air. The knowledge of their respective activity concentration is fundamental for exposure assessments. Due to the complex mixture of activity concentrations in air, its precise determination is quite difficult. Therefore, a new procedure for taking reference samples was developed and implemented for the traceable measurement of the activity concentration of radioactive ions (e.g., radon progenies) in air. This technique is combined by measuring α-particles with a multi-wire ionization chamber for the parallel on-line determination of the activity concentration of different radon isotopes

  12. Research on the multiple linear regression in non-invasive blood glucose measurement.

    Science.gov (United States)

    Zhu, Jianming; Chen, Zhencheng

    2015-01-01

    A non-invasive blood glucose measurement sensor and the data process algorithm based on the metabolic energy conservation (MEC) method are presented in this paper. The physiological parameters of human fingertip can be measured by various sensing modalities, and blood glucose value can be evaluated with the physiological parameters by the multiple linear regression analysis. Five methods such as enter, remove, forward, backward and stepwise in multiple linear regression were compared, and the backward method had the best performance. The best correlation coefficient was 0.876 with the standard error of the estimate 0.534, and the significance was 0.012 (sig. regression equation was valid. The Clarke error grid analysis was performed to compare the MEC method with the hexokinase method, using 200 data points. The correlation coefficient R was 0.867 and all of the points were located in Zone A and Zone B, which shows the MEC method provides a feasible and valid way for non-invasive blood glucose measurement.

  13. Impact of high glucose concentration on aspirin-induced acetylation of human serum albumin: An in vitro study

    Directory of Open Access Journals (Sweden)

    Francesco Finamore

    2014-06-01

    Full Text Available Aspirin (ASA plays a key role in protecting high risk cardiovascular patients from ischaemic events. The modifications underlying its effects are the results of the trans-acetylation that occurs between ASA and the amino groups made up of lysine and N-terminal residues. ASA's effects have also been demonstrated on several plasma proteins, including human serum albumin (HSA. However, its beneficial effects seem to be lower in diabetic patients, suggesting that protein glycation may impair ASA's acetylation process. Using immunoblotting and mass spectrometry, this study characterized the degree of HSA acetylation mediated by ASA in vitro, as well as the impact of high glucose concentrations. Glycation's influence on HSA acetylation might impair the latter's biological functions, leading to a potential failure of ASA to prevent cardiovascular complications in diabetes.

  14. Reflective measurement of water concentration using millimeter wave illumination

    Science.gov (United States)

    Sung, Shijun; Bennett, David; Taylor, Zachary; Bajwa, Neha; Tewari, Priyamvada; Maccabi, Ashkan; Culjat, Martin; Singh, Rahul; Grundfest, Warren

    2011-04-01

    THz and millimeter wave technology have shown the potential to become a valuable medical imaging tool because of its sensitivity to water and safe, non-ionizing photon energy. Using the high dielectric constant of water in these frequency bands, reflectionmode THz sensing systems can be employed to measure water content in a target with high sensitivity. This phenomenology may lead to the development of clinical systems to measure the hydration state of biological targets. Such measurements may be useful in fast and convenient diagnosis of conditions whose symptoms can be characterized by changes in water concentration such as skin burns, dehydration, or chemical exposure. To explore millimeter wave sensitivity to hydration, a reflectometry system is constructed to make water concentration measurements at 100 GHz, and the minimum detectable water concentration difference is measured. This system employs a 100 GHz Gunn diode source and Golay cell detector to perform point reflectivity measurements of a wetted polypropylene towel as it dries on a mass balance. A noise limited, minimum detectable concentration difference of less than 0.5% by mass can be detected in water concentrations ranging from 70% to 80%. This sensitivity is sufficient to detect hydration changes caused by many diseases and pathologies and may be useful in the future as a diagnostic tool for the assessment of burns and other surface pathologies.

  15. Concentration of Radon Progeny in Air by Alpha Spectrometry Measurement

    International Nuclear Information System (INIS)

    Acena, M. L.; Crespo, M. T.

    1989-01-01

    The concentration of radon progeny in air has been determined by alpha spectrometry measurement of 214 Po and 318 Po. A known volume of air was passed through a filter, then the alpha activity was directly measured on this filter. (Author) 15 refs

  16. Increase of extracellular glutamate concentration increases its oxidation and diminishes glucose oxidation in isolated mouse hippocampus: reversible by TFB-TBOA.

    Science.gov (United States)

    Torres, Felipe Vasconcelos; Hansen, Fernanda; Locks-Coelho, Lucas Doridio

    2013-08-01

    Glutamate concentration at the synaptic level must be kept low in order to prevent excitotoxicity. Astrocytes play a key role in brain energetics, and also astrocytic glutamate transporters are responsible for the vast majority of glutamate uptake in CNS. Experiments with primary astrocytic cultures suggest that increased influx of glutamate cotransported with sodium at astrocytes favors its flux to the tricarboxylic acid cycle instead of the glutamate-glutamine cycle. Although metabolic coupling can be considered an emergent field of research with important recent discoveries, some basic aspects of glutamate metabolism still have not been characterized in brain tissue. Therefore, the aim of this study was to investigate whether the presence of extracellular glutamate is able to modulate the use of glutamate and glucose as energetic substrates. For this purpose, isolated hippocampi of mice were incubated with radiolabeled substrates, and CO2 radioactivity and extracellular lactate were measured. Our results point to a diminished oxidation of glucose with increasing extracellular glutamate concentration, glutamate presumably being the fuel, and might suggest that oxidation of glutamate could buffer excitotoxic conditions by high glutamate concentrations. In addition, these findings were reversed when glutamate uptake by astrocytes was impaired by the presence of (3S)-3-[[3-[[4-(trifluoromethyl)benzoyl]amino]phenyl]methoxy]-L-aspartic acid (TFB-TBOA). Taken together, our findings argue against the lactate shuttle theory, because glutamate did not cause any detectable increase in extracellular lactate content (or, presumably, in glycolysis), because the glutamate is being used as fuel instead of going to glutamine and back to neurons. Copyright © 2013 Wiley Periodicals, Inc.

  17. Comparison of predicted and measured variations of indoor radon concentration

    International Nuclear Information System (INIS)

    Arvela, H.; Voutilainen, A.; Maekelaeinen, I.; Castren, O.; Winqvist, K.

    1988-01-01

    Prediction of the variations of indoor radon concentration were calculated using a model relating indoor radon concentration to radon entry rate, air infiltration and meteorological factors. These calculated variations have been compared with seasonal variations of 33 houses during 1-4 years, with winter-summer concentration ratios of 300 houses and the measured diurnal variation. In houses with a slab in ground contact the measured seasonal variations are quite often in agreement with variations predicted for nearly pure pressure difference driven flow. The contribution of a diffusion source is significant in houses with large porous concrete walls against the ground. Air flow due to seasonally variable thermal convection within eskers strongly affects the seasonal variations within houses located thereon. Measured and predicted winter-summer concentration ratios demonstrate that, on average, the ratio is a function of radon concentration. The ratio increases with increasing winter concentration. According to the model the diurnal maximum caused by a pressure difference driven flow occurs in the morning, a finding which is in agreement with the measurements. The model presented can be used for differentiating between factors affecting radon entry into houses. (author)

  18. Effects of glucose and insulin levels on adipose tissue glucose measurement by microdialysis probes retained for three weeks in Type 1 diabetic patients

    NARCIS (Netherlands)

    Hullegie, LM; Lutgers, HL; Dullaart, RPF; Sluiter, WJ; Wientjes, KJ; Schoonen, AJM; Hoogenberg, K

    Background: To evaluate the effects of acute hyperglycaemia and hyperinsulinaemia on adipose tissue glucose measurements by microdialysis probes inserted for a 3-week period. Methods: Microdialysis probes were implanted pairwise in abdominal adipose tissue in seven Type 1 diabetic patients and

  19. Systematic review of randomised controlled trials of the effects of caffeine or caffeinated drinks on blood glucose concentrations and insulin sensitivity in people with diabetes mellitus.

    Science.gov (United States)

    Whitehead, N; White, H

    2013-04-01

    Compounds other than macronutrients have been shown to influence blood glucose concentrations and insulin sensitivity in people with diabetes, with caffeine being one such substance. The present study systematically reviewed the evidence of the effects of caffeine on blood glucose concentrations and/or insulin sensitivity in people with diabetes. Four databases, including MEDLINE and EMBASE, were searched up to 1 February 2012. Randomised controlled trials (RCTs) investigating the effects of caffeine on blood glucose and/or insulin sensitivity in humans, diagnosed with type I, type II or gestational diabetes mellitus (GDM), were included. Quality assessment and data extraction were conducted and agreed by both authors. Of 253 articles retrieved, nine trials (134 participants) were identified. Trials in people with type II diabetes demonstrated that the ingestion of caffeine (approximately 200-500 mg) significantly increased blood glucose concentrations by 16-28% of the area under the curve (AUC) and insulin concentrations by 19-48% of the AUC when taken prior to a glucose load, at the same time as decreasing insulin sensitivity by 14-37%. In type I diabetes, trials indicated enhanced recognition and a reduced duration of hypoglycaemic episodes following ingestion of 400-500 mg caffeine, without altering glycated haemoglobin. In GDM, a single trial demonstrated that approximately 200 mg of caffeine induced a decrease in insulin sensitivity by 18% and a subsequent increase in blood glucose concentrations by 19% of the AUC. Evidence indicates a negative effect of caffeine intake on blood glucose control in individuals with type II diabetes, as replicated in a single trial in GDM. Larger-scale RCTs of longer duration are needed to determine the effects of timing and dose. Early indications of a reduced duration and an improved awareness of hypoglycaemia in type I diabetes require further confirmation. © 2013 The Authors Journal of Human Nutrition and Dietetics

  20. Successful microsurgical lip replantation: Monitoring venous congestion by blood glucose measurements in the replanted lip

    Directory of Open Access Journals (Sweden)

    Kazufumi Tachi

    2018-03-01

    Full Text Available Replantation of an amputated lip using microvascular anastomosis is the best option for restoration of the defect. However, the amputated region often lacks veins with appropriate diameters for microvascular anastomoses and typically necessitates both postoperative exsanguination using medicinal leeches and a blood transfusion. We present a case of the successful replantation of an avulsed lip in which postoperative congestion was evaluated objectively by measuring blood glucose levels in the replanted region. The patient presented to our hospital with an upper lip avulsion that was caused by a dog bite. The lip was replanted by the microvascular anastomoses of one artery and two veins using interposed vein grafts. The replanted lip showed signs of congestion on postoperative day one; exsanguination using medicinal leeches was attempted, while blood glucose levels were measured every three hours. Critical congestion, which did not occur in this patient, was defined as a blood glucose level lower than 40 mg/dL. Lip replantation was successful without any complications in this patient.

  1. Comparing predicted estrogen concentrations with measurements in US waters

    International Nuclear Information System (INIS)

    Kostich, Mitch; Flick, Robert; Martinson, John

    2013-01-01

    The range of exposure rates to the steroidal estrogens estrone (E1), beta-estradiol (E2), estriol (E3), and ethinyl estradiol (EE2) in the aquatic environment was investigated by modeling estrogen introduction via municipal wastewater from sewage plants across the US. Model predictions were compared to published measured concentrations. Predictions were congruent with most of the measurements, but a few measurements of E2 and EE2 exceed those that would be expected from the model, despite very conservative model assumptions of no degradation or in-stream dilution. Although some extreme measurements for EE2 may reflect analytical artifacts, remaining data suggest concentrations of E2 and EE2 may reach twice the 99th percentile predicted from the model. The model and bulk of the measurement data both suggest that cumulative exposure rates to humans are consistently low relative to effect levels, but also suggest that fish exposures to E1, E2, and EE2 sometimes substantially exceed chronic no-effect levels. -- Highlights: •Conservatively modeled steroidal estrogen concentrations in ambient water. •Found reasonable agreement between model and published measurements. •Model and measurements agree that risks to humans are remote. •Model and measurements agree significant questions remain about risk to fish. •Need better understanding of temporal variations and their impact on fish. -- Our model and published measurements for estrogens suggest aquatic exposure rates for humans are below potential effect levels, but fish exposure sometimes exceeds published no-effect levels

  2. The active titration method for measuring local hydroxyl radical concentration

    Science.gov (United States)

    Sprengnether, Michele; Prinn, Ronald G.

    1994-01-01

    We are developing a method for measuring ambient OH by monitoring its rate of reaction with a chemical species. Our technique involves the local, instantaneous release of a mixture of saturated cyclic hydrocarbons (titrants) and perfluorocarbons (dispersants). These species must not normally be present in ambient air above the part per trillion concentration. We then track the mixture downwind using a real-time portable ECD tracer instrument. We collect air samples in canisters every few minutes for roughly one hour. We then return to the laboratory and analyze our air samples to determine the ratios of the titrant to dispersant concentrations. The trends in these ratios give us the ambient OH concentration from the relation: dlnR/dt = -k(OH). A successful measurement of OH requires that the trends in these ratios be measureable. We must not perturb ambient OH concentrations. The titrant to dispersant ratio must be spatially invariant. Finally, heterogeneous reactions of our titrant and dispersant species must be negligible relative to the titrant reaction with OH. We have conducted laboratory studies of our ability to measure the titrant to dispersant ratios as a function of concentration down to the few part per trillion concentration. We have subsequently used these results in a gaussian puff model to estimate our expected uncertainty in a field measurement of OH. Our results indicate that under a range of atmospheric conditions we expect to be able to measure OH with a sensitivity of 3x10(exp 5) cm(exp -3). In our most optimistic scenarios, we obtain a sensitivity of 1x10(exp 5) cm(exp -3). These sensitivity values reflect our anticipated ability to measure the ratio trends. However, because we are also using a rate constant to obtain our (OH) from this ratio trend, our accuracy cannot be better than that of the rate constant, which we expect to be about 20 percent.

  3. Continuous measurement of uranium concentrations with the laser spark

    International Nuclear Information System (INIS)

    Gutmacher, R.G.; Cremers, D.A.; Wachter, J.R.

    1987-01-01

    Laser-induced breakdown spectroscopy has been applied to the continuous determination of uranium concentrations between 0.1 and 300 g/L in flowing solutions. The technique is rapid, noninvasive, and unaffected by radioactivity. A concentration of 10 g/L was measured with 0.8% precision in 3 min. Substances that absorb at the laser wavelength, suspended materials, and variations in the acidity of the solution have little or no effect on the results. High concentrations of zirconium, cadmium, aluminum, or stainless steel in solution do not interfere

  4. Measurement of Non-Invasive Blood Glucose Level Based Sensor Color TCS3200 and Arduino

    Science.gov (United States)

    Kurniadi Wardana, Humaidillah; Indahwati, Elly; Arifah Fitriyah, Lina

    2018-04-01

    Design and measurement of Arduino-based urinary (non-invasive) urine glucose using RGB tcs3200 sensor. This research was conducted by making use of the urine in diabetes patients detected by sensor colours then measured levels of colour based on the RGB colour of the urine of diabetics. The detection is done on 4 urine samples with each consisting of 3 diabetics and 1 non-diabetics. Equipment used in this research, among others, Arduino Uno, colour sensor tcs3200, LCD 16x4. The results showed that the detection of RGB values in diabetics 230 with blue and not diabetics 200 with red.

  5. Biosensor-based analyser. Measurement of glucose, sucrose, lactose, L-lactate and alcohol

    Energy Technology Data Exchange (ETDEWEB)

    Williams, F.T. Jr. (YSI, Inc., Yellow Springs, OH (United States))

    1992-05-01

    This paper describes an instrument, the YSI 2700, for the measurement of glucose, sucrose, lactose, L-lactate, and alcohol by means of biosensors. Each biosensor consists of an amperometric, hydrogen peroxide sensitive electrode combined with an immobilized oxidase enzyme trapped between two membranes. Each biosensor differs from the others only in its enzyme layer. The instrument can be used to measure these analytes in complex sample matrices; often directly, e.g. in whole blood and fermentations, after dilution with water, e.g. in molasses and corn syrup, or after extraction into water, e.g. in cheese and cereal products. (orig.).

  6. Comparison of the Current Diagnostic Criterion of HbA1c with Fasting and 2-Hour Plasma Glucose Concentration

    Science.gov (United States)

    Karnchanasorn, Rudruidee; Huang, Jean; Feng, Wei; Chuang, Lee-Ming

    2016-01-01

    To determine the effectiveness of hemoglobin A1c (HbA1c) ≥ 6.5% in diagnosing diabetes compared to fasting plasma glucose (FPG) ≥ 126 mg/dL and 2-hour plasma glucose (2hPG) ≥ 200 mg/dL in a previously undiagnosed diabetic cohort, we included 5,764 adult subjects without established diabetes for whom HbA1c, FPG, 2hPG, and BMI measurements were collected. Compared to the FPG criterion, the sensitivity of HbA1c ≥ 6.5% was only 43.3% (106 subjects). Compared to the 2hPG criterion, the sensitivity of HbA1c ≥ 6.5% was only 28.1% (110 subjects). Patients who were diabetic using 2hPG criterion but had HbA1c HbA1c ≥ 6.5%. The diagnostic agreement in the clinical setting revealed the current HbA1c ≥ 6.5% is less likely to detect diabetes than those defined by FPG and 2hPG. HbA1c ≥ 6.5% detects less than 50% of diabetic patients defined by FPG and less than 30% of diabetic patients defined by 2hPG. When the diagnosis of diabetes is in doubt by HbA1c, FPG and/or 2hPG should be obtained. PMID:27597979

  7. Measurements in Concentrated Sun using a Remote Controlled Robot

    Directory of Open Access Journals (Sweden)

    Dan Floroian

    2013-04-01

    Full Text Available Nowdays, using the concentrated sunlight is a big issue because the amount of energy is very high and the light is concentrated in a very small area. The main problem in this situation is the heating, and in order to make safe measurements a remote controlled robot is needed. After that, a remote controlled robot will assume the duty of protect the measured sample and to expose it for a precise time to the concentrated sun in order to reduce heating of the sample. For easy operating, and for automatize the process, all the duties, starting with initial conditions, continuing with triggering the measurements, and conditioning the signals and finalizing with data saving must be assured by the robot.

  8. Measurement of average radon gas concentration at workplaces

    International Nuclear Information System (INIS)

    Kavasi, N.; Somlai, J.; Kovacs, T.; Gorjanacz, Z.; Nemeth, Cs.; Szabo, T.; Varhegyi, A.; Hakl, J.

    2003-01-01

    In this paper results of measurement of average radon gas concentration at workplaces (the schools and kindergartens and the ventilated workplaces) are presented. t can be stated that the one month long measurements means very high variation (as it is obvious in the cases of the hospital cave and the uranium tailing pond). Consequently, in workplaces where the expectable changes of radon concentration considerable with the seasons should be measure for 12 months long. If it is not possible, the chosen six months period should contain summer and winter months as well. The average radon concentration during working hours can be differ considerable from the average of the whole time in the cases of frequent opening the doors and windows or using artificial ventilation. (authors)

  9. Maintenance of plasma branched-chain amino acid concentrations during glucose infusion directs essential amino acids to extra-mammary tissues in lactating dairy cows.

    Science.gov (United States)

    Curtis, Richelle V; Kim, Julie J M; Doelman, John; Cant, John P

    2018-05-01

    The objectives of this study were to investigate the effects of branched-chain AA (BCAA) supplementation when glucose is infused postruminally into lactating dairy cows consuming a diet low in crude protein (CP) and to test the hypothesis that low BCAA concentrations are responsible for the poor stimulation of milk protein yield by glucose. Twelve early-lactation Holstein cows were randomly assigned to 15% and 12% CP diets in a switchback design of 6-wk periods. Cows consuming the 12% CP diet received 96-h continuous jugular infusions of saline and 1 kg/d of glucose with 0, 75, or 150 g/d of BCAA in a Latin square sequence of treatments. Compared with saline, glucose infusion did not affect dry matter intake but increased milk yield by 2.2 kg/d and milk protein and lactose yields by 63 and 151 g/d, respectively. Mammary plasma flow increased 36% during glucose infusion compared with saline infusion, possibly because of a 31% decrease in total acetate plus β-hydroxybutyrate concentrations. Circulating concentrations of total essential AA and BCAA decreased 19 and 31%, respectively, during infusion of glucose, yet net mammary uptakes of AA remained unchanged compared with saline infusion. The addition of 75 and 150 g/d of BCAA to glucose infusions increased arterial concentrations of BCAA to 106 and 149%, respectively, of the concentrations in saline-infused cows, but caused a decrease in concentrations of non-branched-chain essential AA in plasma, as well as their mammary uptakes and milk protein yields. Plasma urea concentration was not affected by BCAA infusion, indicating no change in catabolism of AA. The lack of mammary and catabolic effects leads us to suggest that BCAA exerted their effects on plasma concentrations of the other essential AA by stimulating utilization in skeletal muscle for protein accretion. Results indicate that the glucose effect on milk protein yield was not limited by low BCAA concentrations, and that a stimulation of extra-mammary use

  10. TXRF 'measurements' of concentration distribution below the detection limit

    International Nuclear Information System (INIS)

    Kubala-Kukus, A.; Banas, D.; Braziewicz, J.; Majewska, U.; Mrowczynski, S.; Pajek, M.

    2000-01-01

    We demonstrate that a shape of the concentration distribution of the element in a set of samples, as measured by the TXRF method, can be determined even for the concentrations below the detection limit (DL). This can be done, when the measurements reporting the concentration below DL level are included properly in the analysis of the results. The method developed for such correction is presented and discussed. It is demonstrated that this correction is particularly important when the studied concentrations are close to the DL level of the method, which is a common case for TXRF. In the paper a precision of the developed correction is discussed in details, by using the results of numerical simulations of experiments for different concentration distributions and number of performed measurements. It is demonstrated that the factor, which limits the accuracy of the correction, is the number of measurements, not the correction procedure itself. The applicability and importance of the developed correction is demonstrated for routine TXRF analysis of different types of samples of bio-medical interest. (author)

  11. [Joint effect of birth weight and obesity measures on abnormal glucose metabolism at adulthood].

    Science.gov (United States)

    Xi, Bo; Cheng, Hong; Chen, Fangfang; Zhao, Xiaoyuan; Mi, Jie

    2016-01-01

    To investigate the joint effect of birth weight and each of obesity measures (body mass index (BMI) and waist circumference (WC)) on abnormal glucose metabolism (including diabetes) at adulthood. Using the historical cohort study design and the convenience sampling method, 1 921 infants who were born in Beijing Union Medical College Hospital from June 1948 to December 1954 were selected to do the follow-up in 1995 and 2001 respectively. Through Beijing Household Registration and Management System, they were invited to participate in this study. A total of 972 subjects (627 were followed up in 1995 and 345 were followed up in 2001) with complete information on genders, age, birth weight, family history of diabetes, BMI, WC, fasting plasma glucose (FPG) and 2-hour plasma glucose (2 h PG) met the study inclusion criteria at the follow-up visits. In the data analysis, they were divided into low, normal, and high birth weight, respectively. The ANOVA and Chi-squared tests were used to compare the differences in their characteristics by birth weight group. In addition, multiple binary Logistic regression model was used to investigate the single effect of birth weight, BMI, and waist circumference on abnormal glucose metabolism at adulthood. Stratification analysis was used to investigate the joint effect of birth weight and each of obesity measures (BMI and WC) on abnormal glucose metabolism. There were 972 subjects (males: 50.7%, mean age: (46.0±2.2) years) included in the final data analysis. The 2 h PG in low birth weight group was (7.6±3.2) mmol/L , which was higher than that in normal birth weight group (6.9±2.1) mmol/L and high birth weight group (6.4±1.3) mmol/L (F=3.88, P=0.021). After adjustment for genders, age, body length, gestation age, family history of diabetes, physical activity, smoking and alcohol consumption, and duration of follow-up, subjects with overweight and obesity at adulthood had 2.73 (95% confidence interval (CI) =2.06- 3.62) times risk

  12. QA/QC For Radon Concentration Measurement With Charcoal Canister

    International Nuclear Information System (INIS)

    Pantelic, G.; Zivanovic, M.; Rajacic, M.; Krneta Nikolic, J.; Todorovic, D.

    2015-01-01

    The primary concern of any measuring of radon or radon progeny must be the quality of the results. A good quality assurance program, when properly designed and diligently followed, ensures that laboratory staff will be able to produce the type and quality of measurement results which is needed and expected. Active charcoal detectors are used for testing the concentration of radon in dwellings. The method of measurement is based on radon adsorption on coal and measurement of gamma radiation of radon daughters. Upon closing the detectors, the measurement was carried out after achieving the equilibrium between radon and its daughters (at least 3 hours) using NaI or HPGe detector. Radon concentrations as well as measurement uncertainties were calculated according to US EPA protocol 520/5-87-005. Detectors used for the measurements were calibrated by 226Ra standard of known activity in the same geometry. Standard and background canisters are used for QA and QC, as well as for the calibration of the measurement equipment. Standard canister is a sealed canister with the same matrix and geometry as the canisters used for measurements, but with the known activity of radon. Background canister is a regular radon measurement canister, which has never been exposed. The detector background and detector efficiency are measured to ascertain whether they are within the warning and acceptance limits. (author).

  13. Fissile materials in solution concentration measured by active neutron interrogation

    International Nuclear Information System (INIS)

    Romeyer Dherbey, J.; Passard, Ch.; Cloue, J.; Bignan, G.

    1993-01-01

    The use of the active neutron interrogation to measure the concentration of plutonium contained in flow solutions is particularly interesting for fuel reprocessing plants. Indeed, this method gives a signal which is in a direct relation with the fissile materials concentration. Moreover, it is less sensitive to the gamma dose rate than the other nondestructive methods. Two measure methods have been evolved in CEA. Their principles are given into details in this work. The first one consists to detect fission delayed neutrons induced by a 252 Cf source. In the second one fission prompt neutrons induced by a neutron generator of 14 MeV are detected. (O.M.)

  14. Variation in 125I-Insulin absorption and blood glucose concentration

    International Nuclear Information System (INIS)

    Lauritzen, T.; Faber, O.K.; Binder, C.

    1979-01-01

    The absorption of monocomponent porcine 125 I-insulin Monotard and Isophane was studied in six insulin dependent diabetic patients over a period of 12 days. The absorption of insulin was measured as the disappearance of radioactivity from sites of injection. The daily 125 I-insulin doses ranged from 20 to 48 IU between patients. The insulin absorbed varied considerably within and between patients. The range of individual daily absorbed insulin varied from 19 to 104 per cent of the 125 I-insulin dose. A significant correlation (p [de

  15. Measurement of radon concentration in water with Lucas cell detector

    International Nuclear Information System (INIS)

    Machaj, B.; Pienkos, J.P.

    2003-01-01

    A method for the measurement of radon concentration in water is presented based on flushing a water sample with air in a closed loop with the Lucas cell as alpha radiation detector. The main feature of the method is washing radon away from the larger sample of water (0.75 l) to a small volume of air, approximately 0.5 l, thanks to which a high radon concentration in air and a considerable sensitivity of measurement is achieved. Basic relations and results of measurements of a model of a gauge is given. The estimated measuring sensitivity (S) is 8.5 (cpm)/(Bq/l). The random error due to the statistical fluctuations of count rate at radon concentrations 1,10, 100, 1000, 10000 Bq/l is 11, 3.6, 1.1, 0.4, 0.1% correspondingly at a counting (measuring) time of 10 min. The minimum detectable radon concentration in water is 0.11 Bq/l. (author)

  16. Measurement of temporal asymmetries of glucose consumption using linear profiles: reproducibility and comparison with visual analysis

    International Nuclear Information System (INIS)

    Matheja, P.; Kuwert, T.; Schaefers, M.; Schaefers, K.; Schober, O.; Diehl, B.; Stodieck, S.R.G.; Ringelstein, E.B.; Schuierer, G.

    1998-01-01

    The aim of our study was to test the reproducibility of this method and to compare its diagnostic performance to that of visual analysis in patients with complex partial seizures (CPS). Regional cerebral glucose consumption (rCMRGLc) was measured interictally in 25 CPS patients and 10 controls using F-18-deoxyglucose and the positron emission tomography (PET) camera ECAT EXACT 47. The PET scans were visually analyzed for the occurrence of unilateral temporal hypometabolism. Furthermore, rCMRGLc was quantified on six contiguous coronal planes by manually tracing maximal values of temporal glucose consumption, thus creating line profiles of temporal glucose consumption for each side. Indices of asymmetry (ASY) were then calculated from these line profiles in four temporal regions and compared to the corresponding 95% confidence intervals of the control data. All analyses were performed by two observers independently from each other and without knowledge of the clinical findings. The agreement between the two observers with regard to focus lateralization was 96% on visual analysis and 100% on quantitative analysis. There was an excellent agreement with regard to focus lateralization between visual and quantitative evaluation. (orig.) [de

  17. Effects of concentrated arabinoxylan and β-glucan compared with refined wheat and whole grain rye on glucose and appetite in subjects with the metabolic syndrome

    DEFF Research Database (Denmark)

    Hartvigsen, M L; Gregersen, S; Lærke, H N

    2014-01-01

    BACKGROUND/OBJECTIVES: Several studies emphasise that arabinoxylan and β-glucan have more beneficial effects on glucose metabolism than low-dietary fibre (DF) meals. Less attention has been paid to the effects of concentrated DF compared with whole grain. We compared the effects of DF and whole...... grain on glucose, hormone responses and appetite in subjects with the metabolic syndrome (MetS). SUBJECTS/METHODS: Fifteen subjects with MetS participated in this acute, randomised, cross-over intervention study. The test breads provided 50 g of digestible carbohydrate: wheat bread with concentrated...

  18. Investigation of (/sup 18/F)2-fluoro-2-deoxyglucose for the measure of myocardial glucose metabolism

    Energy Technology Data Exchange (ETDEWEB)

    Phelps, M.E.; Hoffman, E.J.; Selin, C.; Huang, S.C.; Robinson, G.; MacDonald, N.; Schelbert, H.; Kuhl, D.E.

    1978-12-01

    Fluorine-18-labeled 2-deoxyglucose (FDG) was studied as a glucose analog for the measure of myocardial glucose metabolism. Myocardial uptake and retention, blood clearance, species dependence (dog, monkey, man), and effect of diet on uptake were investigated. Normal myocardial uptake of FDG was 3 to 4% of injected dose in dog and monkey, and 1 to 4% in man, compared with brain uptakes of 1.5 to 3% in dog, 5 to 6% in monkey, and 4 to 8% in man. The myocardial metabolic rate (MR) for glucose in the nonfasting (glycolytic) state was 2.8 times that in the fasting (ketogenic) state. Human subjects showed higher myocardial uptake after a normal meal than after a meal containing mostly free fatty acids (FFA). Blood clearance was rapid with initial clearance t/sub 1/2/ of 0.2 to 0.3 min, followed by a t/sub 1/2/ of 8.4 +- 1.2 min in dog and 11.6 +- 1.1 min in man. A small third component had half-times of 59 +- 10 min and 88 +- 4 min in dog and man, respectively. With the ECAT positron tomograph, high image-contrast ratios were found between heart and blood (dog 3.5/1, man 14/1), heart and lung (dog 9/1, man 20/1), and heart and liver (dog 15/1, man 10/1). The FDG was taken up rapidly by the myocardium without any significant tissue clearance over a 4-hr period. The FDG exhibited excellent imaging properties. Average counting rates of 12K, 20K, and 40K c/min-mCi injected are obtained in human subjects with high, medium, and low resolutions of the ECAT tomograph. Determination of glucose and FFA MR in vivo with EACT provides a method for investigation and assessment of changing aerobic and anaerobic metabolic rates in ischemic heart disease in man.

  19. Investigation of [18F]2-fluoro-2-deoxyglucose for the measure of myocardial glucose metabolism

    International Nuclear Information System (INIS)

    Phelps, M.E.; Hoffman, E.J.; Selin, C.; Huang, S.C.; Robinson, G.; MacDonald, N.; Schelbert, H.; Kuhl, D.E.

    1978-01-01

    Fluorine-18-labeled 2-deoxyglucose (FDG) was studied as a glucose analog for the measure of myocardial glucose metabolism. Myocardial uptake and retention, blood clearance, species dependence (dog, monkey, man), and effect of diet on uptake were investigated. Normal myocardial uptake of FDG was 3 to 4% of injected dose in dog and monkey, and 1 to 4% in man, compared with brain uptakes of 1.5 to 3% in dog, 5 to 6% in monkey, and 4 to 8% in man. The myocardial metabolic rate (MR) for glucose in the nonfasting (glycolytic) state was 2.8 times that in the fasting (ketogenic) state. Human subjects showed higher myocardial uptake after a normal meal than after a meal containing mostly free fatty acids (FFA). Blood clearance was rapid with initial clearance t/sub 1/2/ of 0.2 to 0.3 min, followed by a t/sub 1/2/ of 8.4 +- 1.2 min in dog and 11.6 +- 1.1 min in man. A small third component had half-times of 59 +- 10 min and 88 +- 4 min in dog and man, respectively. With the ECAT positron tomograph, high image-contrast ratios were found between heart and blood (dog 3.5/1, man 14/1), heart and lung (dog 9/1, man 20/1), and heart and liver (dog 15/1, man 10/1). The FDG was taken up rapidly by the myocardium without any significant tissue clearance over a 4-hr period. The FDG exhibited excellent imaging properties. Average counting rates of 12K, 20K, and 40K c/min-mCi injected are obtained in human subjects with high, medium, and low resolutions of the ECAT tomograph. Determination of glucose and FFA MR in vivo with EACT provides a method for investigation and assessment of changing aerobic and anaerobic metabolic rates in ischemic heart disease in man

  20. Measurement of plasma homovanillic acid concentrations in schizophrenic patients.

    Science.gov (United States)

    Kaminski, R; Powchick, P; Warne, P A; Goldstein, M; McQueeney, R T; Davidson, M

    1990-01-01

    1. Several lines of evidence suggest that abnormalities of central dopaminergic transmission may be involved in the expression of some schizophrenic symptoms. However, elucidation of the role of dopamine (DA) in schizophrenia has eluded investigative efforts partially because no accurate and easily repeatable measure of brain DA activity exists. 2. The development of a technique to measure homovanillic acid in plasma has offered the possibility of performing serial measurements of this major DA metabolite. 3. Assuming that plasma homovanillic acid (PHVA) concentrations is an index of brain DA activity, measurement of PHVA can play a role in elucidating the DA abnormality in schizophrenia. 4. Results to date suggest that plasma homovanillic acid concentrations are lower in chronic schizophrenic patients compared to normal controls, and that PHVA values correlate with schizophrenic symptom severity. 5. In addition, PHVA levels were shown to initially rise and subsequently decline during chronic neuroleptic administration in treatment responsive but not in treatment refractory schizophrenic patients.

  1. Myocardial scintigraphy with 16 /sup 123/I hexadecene 9 oique acid: influence of plasma concentrations of fatty acids and glucose

    Energy Technology Data Exchange (ETDEWEB)

    Comet, M.; Pilichowski, P.; Wolf, J.E.; Busquet, G.; Dubois, F.; Mathieu, J.P.; Pernin, C.; Riche, F. (C.H.R.U. de Grenoble (France)); Vidal, M. (U.S.M.G., 38 - Grenoble (France))

    1983-01-01

    After I.V. injection of /sup 123/I hexadecene-9 oic acid to dogs, the decreasing part of the myocardial activity curve is fitted with an exponential which period is calculated. Then the procedure is repeated after I.V. injection of heparin alone (6 dogs), of heparin during an intralipid perfusion (6 dogs) and lastly during a perfusion of a solution of glucose, insulin and potassium (7 dogs). In the two last protocols only, the period of the curve is significantly increased. The increase of the period means perhaps an increase of the intracellular accumulation of fatty acids. Patients must be in the same nutritional state to allow comparison between periods and a measure of the plasma level of NEFA is necessary before each injection of the labelled fatty acid.

  2. Myocardial scintigraphy with 16 123I hexadecene 9 oique acid: influence of plasma concentrations of fatty acids and glucose

    International Nuclear Information System (INIS)

    Comet, M.; Pilichowski, P.; Wolf, J.E.; Busquet, G.; Dubois, F.; Mathieu, J.P.; Pernin, C.; Riche, F.; Vidal, M.

    1983-01-01

    After I.V. injection of 123 I hexadecene-9 oic acid to dogs, the decreasing part of the myocardial activity curve is fitted with an exponential which period is calculated. Then the procedure is repeated after I.V. injection of heparin alone (6 dogs), of heparin during an intralipid perfusion (6 dogs) and lastly during a perfusion of a solution of glucose, insulin and potassium (7 dogs). In the two last protocols only, the period of the curve is significantly increased. The increase of the period means perhaps an increase of the intracellular accumulation of fatty acids. Patients must be in the same nutritional state to allow comparison between periods and a measure of the plasma level of NEFA is necessary before each injection of the labelled fatty acid [fr

  3. Fiber Optic Displacement Sensor for Measuring Cholesterol Concentration

    Directory of Open Access Journals (Sweden)

    Moh. Budiyanto

    2017-11-01

    Full Text Available A simple design of a cholesterol concentration detection is proposed and demonstrated using a fiber optic displacement sensor based on an intensity modulation technique. The proposed sensor uses a bundled plastic optical fiber (POF as a probe in conjunction with a flat mirror as a target. It is obtained that the peak voltage reduces with increasing cholesterol concentration. The sensor is capable of measuring the cholesterol concentration ranging from 0 to 300 ppm in a distilled water with a measured sensitivity of 0.01 mV/ppm, a linearity of more than 99.62 % and a resolution of 3.9188 ppm. The proposed sensor also shows a high degree of stability and good repeatability. The simplicity of design, accuracy, flexible dynamic range, and the low cost of fabrication are favorable attributes of the sensor and beneficial for real- field applications. Fiber optic sensors

  4. Hollow optical-fiber based infrared spectroscopy for measurement of blood glucose level by using multi-reflection prism.

    Science.gov (United States)

    Kino, Saiko; Omori, Suguru; Katagiri, Takashi; Matsuura, Yuji

    2016-02-01

    A mid-infrared attenuated total reflection (ATR) spectroscopy system employing hollow optical fibers and a trapezoidal multi-reflection ATR prism has been developed to measure blood glucose levels. Using a multi-reflection prism brought about higher sensitivity, and the flat and wide contact surface of the prism resulted in higher measurement reproducibility. An analysis of in vivo measurements of human inner lip mucosa revealed clear signatures of glucose in the difference spectra between ones taken during the fasting state and ones taken after ingestion of glucose solutions. A calibration plot based on the absorption peak at 1155 cm(-1) that originates from the pyranose ring structure of glucose gave measurement errors less than 20%.

  5. Metformin inhibition of mTORC1 activation, DNA synthesis and proliferation in pancreatic cancer cells: Dependence on glucose concentration and role of AMPK

    Energy Technology Data Exchange (ETDEWEB)

    Sinnett-Smith, James; Kisfalvi, Krisztina; Kui, Robert [Division of Digestive Diseases, Department of Medicine, CURE: Digestive Diseases Research Center, David Geffen School of Medicine and Molecular Biology Institute, University of California at Los Angeles, CA (United States); Rozengurt, Enrique, E-mail: erozengurt@mednet.ucla.edu [Division of Digestive Diseases, Department of Medicine, CURE: Digestive Diseases Research Center, David Geffen School of Medicine and Molecular Biology Institute, University of California at Los Angeles, CA (United States)

    2013-01-04

    Highlights: Black-Right-Pointing-Pointer Metformin inhibits cancer cell growth but the mechanism(s) are not understood. Black-Right-Pointing-Pointer We show that the potency of metformin is sharply dependent on glucose in the medium. Black-Right-Pointing-Pointer AMPK activation was enhanced in cancer cells incubated in physiological glucose. Black-Right-Pointing-Pointer Reciprocally, metformin potently inhibited mTORC1, DNA synthesis and proliferation. Black-Right-Pointing-Pointer Metformin, at low concentrations, inhibited DNA synthesis through AMPK. -- Abstract: Metformin, a widely used anti-diabetic drug, is emerging as a potential anticancer agent but the mechanisms involved remain incompletely understood. Here, we demonstrate that the potency of metformin induced AMPK activation, as shown by the phosphorylation of its substrates acetyl-CoA carboxylase (ACC) at Ser{sup 79} and Raptor at Ser{sup 792}, was dramatically enhanced in human pancreatic ductal adenocarcinoma (PDAC) cells PANC-1 and MiaPaCa-2 cultured in medium containing physiological concentrations of glucose (5 mM), as compared with parallel cultures in medium with glucose at 25 mM. In physiological glucose, metformin inhibited mTORC1 activation, DNA synthesis and proliferation of PDAC cells stimulated by crosstalk between G protein-coupled receptors and insulin/IGF signaling systems, at concentrations (0.05-0.1 mM) that were 10-100-fold lower than those used in most previous reports. Using siRNA-mediated knockdown of the {alpha}{sub 1} and {alpha}{sub 2} catalytic subunits of AMPK, we demonstrated that metformin, at low concentrations, inhibited DNA synthesis through an AMPK-dependent mechanism. Our results emphasize the importance of using medium containing physiological concentrations of glucose to elucidate the anticancer mechanism of action of metformin in pancreatic cancer cells and other cancer cell types.

  6. Metformin inhibition of mTORC1 activation, DNA synthesis and proliferation in pancreatic cancer cells: Dependence on glucose concentration and role of AMPK

    International Nuclear Information System (INIS)

    Sinnett-Smith, James; Kisfalvi, Krisztina; Kui, Robert; Rozengurt, Enrique

    2013-01-01

    Highlights: ► Metformin inhibits cancer cell growth but the mechanism(s) are not understood. ► We show that the potency of metformin is sharply dependent on glucose in the medium. ► AMPK activation was enhanced in cancer cells incubated in physiological glucose. ► Reciprocally, metformin potently inhibited mTORC1, DNA synthesis and proliferation. ► Metformin, at low concentrations, inhibited DNA synthesis through AMPK. -- Abstract: Metformin, a widely used anti-diabetic drug, is emerging as a potential anticancer agent but the mechanisms involved remain incompletely understood. Here, we demonstrate that the potency of metformin induced AMPK activation, as shown by the phosphorylation of its substrates acetyl-CoA carboxylase (ACC) at Ser 79 and Raptor at Ser 792 , was dramatically enhanced in human pancreatic ductal adenocarcinoma (PDAC) cells PANC-1 and MiaPaCa-2 cultured in medium containing physiological concentrations of glucose (5 mM), as compared with parallel cultures in medium with glucose at 25 mM. In physiological glucose, metformin inhibited mTORC1 activation, DNA synthesis and proliferation of PDAC cells stimulated by crosstalk between G protein-coupled receptors and insulin/IGF signaling systems, at concentrations (0.05–0.1 mM) that were 10–100-fold lower than those used in most previous reports. Using siRNA-mediated knockdown of the α 1 and α 2 catalytic subunits of AMPK, we demonstrated that metformin, at low concentrations, inhibited DNA synthesis through an AMPK-dependent mechanism. Our results emphasize the importance of using medium containing physiological concentrations of glucose to elucidate the anticancer mechanism of action of metformin in pancreatic cancer cells and other cancer cell types.

  7. Measurements of radon activity concentrations in air at Niska spa

    International Nuclear Information System (INIS)

    Adrovic, F.; Vuckovic, B.; Ninkovic, M.

    2004-01-01

    Radon activity concentrations in air were measured in the recreational-tourist center of Niska Banja. Alpha Guard PQ 2000/ MC50 instrumentation (Genitron instruments, Frankfurt) was used. The observed indoor radon concentrations in the air of the Radon Hotel pool lay within the range of 0.980-1.908 kBq/m 3 and were directly dependent on the exhalation of radon from thermomineral waters. Radon concentrations were also measured outdoors, at locations for capping thermomineral water, as well as at locations for draining used water from the Radon Hotel pool. Outdoor radon concentrations as high as over 500 Bq/m 3 were observed. Gamma dose rates were measured in parallel and found to lie within the range of 72-420 nSv/h. The gamma doses correlated well with the observed radon levels. The largest gamma dose rates in air were measured in the pool of Radon Hotel and at the site where this thermomineral water is being capped

  8. Measurements of ion concentration in gasoline and diesel engine exhaust

    Science.gov (United States)

    Yu, Fangqun; Lanni, Thomas; Frank, Brian P.

    The nanoparticles formed in motor vehicle exhaust have received increasing attention due to their potential adverse health effects. It has been recently proposed that combustion-generated ions may play a critical role in the formation of these volatile nanoparticles. In this paper, we design an experiment to measure the total ion concentration in motor vehicle engine exhaust, and report some preliminary measurements in the exhaust of a gasoline engine (K-car) and a diesel engine (diesel generator). Under the experimental set-up reported in this study and for the specific engines used, the total ion concentration is ca. 3.3×10 6 cm -3 with almost all of the ions smaller than 3 nm in the gasoline engine exhaust, and is above 2.7×10 8 cm -3 with most of the ions larger than 3 nm in the diesel engine exhaust. This difference in the measured ion properties is interpreted as a result of the different residence times of exhaust inside the tailpipe/connecting pipe and the different concentrations of soot particles in the exhaust. The measured ion concentrations appear to be within the ranges predicted by a theoretical model describing the evolution of ions inside a pipe.

  9. Laser system for measuring small changes in plasma tracer concentrations.

    Science.gov (United States)

    Klaesner, J W; Pou, N A; Parker, R E; Galloway, R L; Roselli, R J

    1996-01-01

    The authors developed a laser-diode system that can be used for on-line optical concentration measurements in physiologic systems. Previous optical systems applied to whole blood have been hampered by artifacts introduced by red blood cells (RBCs). The system introduced here uses a commercially available filter cartridge to separate RBCs from plasma before plasma concentration measurements are made at a single wavelength. The filtering characteristics of the Cellco filter cartridge (#4007-10, German-town, MD) were adequate for use in the on-line measurement system. The response time of the filter cartridge was less than 40 seconds, and the sieving characteristics of the filter for macromolecules were excellent, with filtrate-to-plasma albumin ratios of 0.98 +/- 0.11 for studies in sheep and 0.94 +/- 0.15 for studies in dogs. The 635-nm laser diode system developed was shown to be more sensitive than the spectrophotometer used in previous studies (Klaesner et al., Annals of Biomedical Engineering, 1994; 22, 660-73). The new system was used to measure the product of filtration coefficient (Kfc) and reflection coefficient for albumin (delta f) in an isolated canine lung preparation. The delta fKfc values [mL/(cmH2O.min.100 g dry lung weight)] measured with the laser diode system (0.33 +/- 0.22) compared favorably with the delta fKfc obtained using a spectrophotometer (0.27 +/- 0.20) and with the Kfc obtained using the blood-corrected gravimetric method (0.32 +/- 0.23). Thus, this new optical system was shown to accurately measure plasma concentration changes in whole blood for physiologic levels of Kfc. The same system can be used with different optical tracers and different source wavelengths to make optical plasma concentration measurements for other physiologic applications.

  10. Cytotoxicity of β-D-glucose/sucrose-coated silver nanoparticles depends on cell type, nanoparticles concentration and time of incubation

    Science.gov (United States)

    Vergallo, Cristian; Panzarini, Elisa; Carata, Elisabetta; Ahmadi, Meysam; Mariano, Stefania; Tenuzzo, Bernardetta Anna; Dini, Luciana

    2016-06-01

    The use of silver NanoParticles (AgNPs) in several consumer commercialized products, like food contact materials, medical devices and cosmetics has increased significantly, owing to their antibacterial and antifungal properties. Even though the NPs are widely diffused, due to the great variety in size, coating or shape, controversial data on their possible detrimental health effects still exist. Herein, by performing an easy and fast green method synthesis, we used β-D-glucose/sucrose to stabilize AgNPs and avoid the release of cytotoxic soluble silver ions Ag+ in the culture medium. The cytotoxic effects of these β-D-Glucose/Sucrose-Coated AgNPs (AgNPs-GS) was assessed on two cell culture models, which are human liver HepG2 and human Peripheral Blood Lymphocytes (PBLs) cells. AgNPs-GS, as determined by Transmission Electron Microscopy (TEM) analyses, had an average diameter of 30±5 nm, a spherical shape and were well-dispersed in the freshly-prepared solution. In addition, they were found spectrophotometrically stable throughout the experiment. Cytotoxicity, determined by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) reduction assay, was evaluated by using two AgNPs-GS amounts, indicated as highest (10×103 of NPs/cell) and lowest (2×103 NPs/cell) concentration for 6, 12 and 24 h. The highest concentration of AgNPs-GS was significantly cytotoxic for both HepG2 and PBLs cells at all times, when compared with the negative control; conversely, the lowest amount of AgNPs-GS was toxic only for HepG2 cells. A significant increase of Reactive Oxygen Species (ROS) levels, determined by Nitro Blue Tetrazolium (NBT) reduction assay, was observed only in PBLs after treatment with NPs, by reaching maximum levels after the incubation with the lowest amount of NPs for 24 h. Significant morphological changes, depending on NPs/cell amount, characteristic of cell toxicity, like shape, cytoplasm, and nucleus alterations, were observed in lymphocytes and Hep

  11. Radon concentration measurements in the desert caves of Saudi Arabia

    International Nuclear Information System (INIS)

    Al-Mustafa, Hanan; Al-Jarallah, M.I.; Fazal-ur-Rehman; Abu-Jarad, F.

    2005-01-01

    Beneath the harsh deserts of Saudi Arabia lie dark chambers and complex mazes filled with strange shapes and wondrous beauty. Radon concentration measurements have been carried out in the desert caves of Al-Somman Plateau in the Eastern Province of Saudi Arabia. Passive radon dosimeters, based on alpha particle etch track detectors with an inlet filter, were used in this study. A total of 59 dosimeters were placed in five caves for a period of six months. Out of 59 dosimeters, 37 could be collected for analysis. Measurements showed significant variations in radon concentrations in caves depending upon their natural ventilation. The results of the study show that the average radon concentration in the different caves ranges from 74 up to 451Bqm -3 . The average radon concentration in four of the caves was low in the range 74-114Bqm -3 . However, one cave showed an average radon concentration of 451Bqm -3 . Radon is not a problem for tourists in the majority of caves. However, sometimes it may imply some limitation to the working time of guides

  12. Radon concentration measurements in the desert caves of Saudi Arabia

    Energy Technology Data Exchange (ETDEWEB)

    Al-Mustafa, Hanan [Women College, P. O. Box 838, Dammam 31113 (Saudi Arabia); Al-Jarallah, M.I. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)]. E-mail: mibrahim@kfupm.edu.sa; Fazal-ur-Rehman [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Abu-Jarad, F. [Radiation Protection Unit, Environmental Protection Department, Saudi Aramco P.O. Box 13027, Dhahran 31311 (Saudi Arabia)

    2005-11-15

    Beneath the harsh deserts of Saudi Arabia lie dark chambers and complex mazes filled with strange shapes and wondrous beauty. Radon concentration measurements have been carried out in the desert caves of Al-Somman Plateau in the Eastern Province of Saudi Arabia. Passive radon dosimeters, based on alpha particle etch track detectors with an inlet filter, were used in this study. A total of 59 dosimeters were placed in five caves for a period of six months. Out of 59 dosimeters, 37 could be collected for analysis. Measurements showed significant variations in radon concentrations in caves depending upon their natural ventilation. The results of the study show that the average radon concentration in the different caves ranges from 74 up to 451Bqm{sup -3}. The average radon concentration in four of the caves was low in the range 74-114Bqm{sup -3}. However, one cave showed an average radon concentration of 451Bqm{sup -3}. Radon is not a problem for tourists in the majority of caves. However, sometimes it may imply some limitation to the working time of guides.

  13. Estimates of CO2 traffic emissions from mobile concentration measurements

    Science.gov (United States)

    Maness, H. L.; Thurlow, M. E.; McDonald, B. C.; Harley, R. A.

    2015-03-01

    We present data from a new mobile system intended to aid in the design of upcoming urban CO2-monitoring networks. Our collected data include GPS probe data, video-derived traffic density, and accurate CO2 concentration measurements. The method described here is economical, scalable, and self-contained, allowing for potential future deployment in locations without existing traffic infrastructure or vehicle fleet information. Using a test data set collected on California Highway 24 over a 2 week period, we observe that on-road CO2 concentrations are elevated by a factor of 2 in congestion compared to free-flow conditions. This result is found to be consistent with a model including vehicle-induced turbulence and standard engine physics. In contrast to surface concentrations, surface emissions are found to be relatively insensitive to congestion. We next use our model for CO2 concentration together with our data to independently derive vehicle emission rate parameters. Parameters scaling the leading four emission rate terms are found to be within 25% of those expected for a typical passenger car fleet, enabling us to derive instantaneous emission rates directly from our data that compare generally favorably to predictive models presented in the literature. The present results highlight the importance of high spatial and temporal resolution traffic data for interpreting on- and near-road concentration measurements. Future work will focus on transport and the integration of mobile platforms into existing stationary network designs.

  14. Market power in electricity markets: Beyond concentration measures

    International Nuclear Information System (INIS)

    Borenstein, S.; Bushnell, J.; Knittel, C.R.

    1999-01-01

    The wave of electricity market restructuring both within the US and abroad has brought the issue of horizontal market power to the forefront of energy policy. Traditionally, estimation and prediction of market power has relied heavily on concentration measures. In this paper, the authors discuss the weaknesses of concentration measures as a viable measure of market power in the electricity industry, and they propose an alternative method based on market simulations that take advantage of existing plant level data. The authors discuss results from previous studies they have performed, and present new results that allow for the detection of threshold demand levels where market power is likely to be a problem. In addition, the authors analyze the impact of that recent divestitures in the California electricity market will have on estimated market power. They close with a discussion of the policy implications of the results

  15. Measurement of 222Rn in soil concentrations in interstitial air

    International Nuclear Information System (INIS)

    Duenas, C.; Fernandez, M.C.; Carretero, J.; Liger, E.

    1996-01-01

    Measurements of 222 Rn soil concentrations were made by inserting stainless-steel sampling tubes into the soil. The samples of the soil interstitial air were taken in to pre-evacuated 1 L glass flasks. The glass flasks are cylindrical and coated with a film of ZnS(Ag). 222 Rn was measured by counting the alpha particles emitted by 222 Rn and its daughter products, 218 Po and 214 Bi, when they reached radioactive equilibrium. Measurements of 222 Rn gas concentrations in the soil air interstices by the method at different depths were used to calculate the diffusion coefficient of the 222 Rn in the soil air. This study has been carried out for diverse soils. (Author)

  16. Performance tests for instruments measuring radon activity concentration

    International Nuclear Information System (INIS)

    Beck, T.R.; Buchroeder, H.; Schmidt, V.

    2009-01-01

    Performance tests of electronic instruments measuring the activity concentration of 222 Rn have been carried out with respect to the standard IEC 61577-2. In total, 9 types of instrument operating with ionization chambers or electrostatic collection have been tested for the influence of different climatic and radiological factors on the measurement characteristics. It is concluded that all types of instrument, which are commercially available, are suitable for indoor radon measurements. Because of the dependence on climatic conditions, the outdoor use is partly limited.

  17. Measurement of mean radon concentrations in the Tokai districts

    International Nuclear Information System (INIS)

    Iida, Takao; Ikebe, Yukimasa; Yamanishi, Hirokuni

    1989-01-01

    This paper describes an electrostatic integrating radon monitor designed for the environmental radon monitoring and longterm measurements of mean radon concentrations in outdoor and indoor air. The position of the collecting electrode within the monitor was determined based on the calculation of the internal electric field. The radon exchange rate between the monitor and the outside air through the filter was 0.75 h -1 . The exchange rate can make the radon concentration inside the monitor to follow thoroughly the outside concentration. Since the electrostatic collection of RaA + ( 218 Po + ) atoms depends on the humidity of the air, the inside of the monitor was dehumidified with a diphosphorus pentaoxide (P 2 O 5 ) drying agent which is powerful and dose not absorb radon gas. From the relationship between track density and radon exposure, the calibration factor was derived to be 0.52 ± 0.002 tracks cm -2 (Bq m -3 h) -1 . The detection limit of mean radon level is 1.2 Bq m -3 for an exposure time fo 2 months. The mean radon concentrations in various environments were measured through the year using the monitors this developed. The annual mean outdoor radon level in the Tokai districts was 7.0 Bq m -3 . The mean radon concentrations was found to vary from 3.5 to 11.7 Bq m -3 depending upon the geographical conditions even in this relatively small region. The annual indoor radon concentrations at Nagoya and Sapporo ranged from 6.4 to 11.9 Bq m -3 and from 15.5 to 121.1 Bq m -3 , respectively, with the type of building material and the ventilation rate. The mean radon concentrations in tightly built houses selected at Sapporo are about 10 times as high as those in drafty houses at Nagoya. (author)

  18. Radon concentration measurements in waters in Greece and Cyprus

    International Nuclear Information System (INIS)

    Louizi, A.; Nikolopoulos, D.; Tzortzi, A.; Thanassas, D.; Serefoglou, A.; Georgiou, E.; Vogiannis, E.; Koukouliou, V.

    2004-01-01

    A total of 35 measurements in Greece and 15 in Cyprus were performed. Radon concentrations in drinking water in Greece were from (1.1±0.5) to (410±50) Bq/L. The corresponding concentrations in underground potable waters in Cyprus ranged between (0.4±0.3) Bq/L and (15±4) Bq/L. High concentrations, viz. (120±20), (320±40) and (410±50) Bq/L, were observed in three samples collected from the city of Arnea Chalkidekis in northern Greece. One water sample from Lesvos Island (north-eastern part of Greece) exhibited a radon concentration of (140±20) Bq/L. Six samples of hot spring water from the city of Loutraki (Attica prefecture), characterized as 'medicinal drinking water', contained concentrations of radon between (220±10) and (340±20) Bq/L. Radon concentrations in potable and non-potable underground water in Greece and Cyprus ranged between (0.4±0.3) and (15±4) Bq/L, whereas in surface water the range was from (2.7±0.8) to (24±6) Bq/L. (P.A.)

  19. Chaos based blood glucose noninvasive measurement: new concept and custom study

    Directory of Open Access Journals (Sweden)

    Cui Li

    2017-01-01

    Full Text Available Background. Non invasive monitoring of Blood Glucose (BG has been a challenge calling for new accurate and fast measurement methods. Objective. To propose new concept of chaos based BG non invasive test aiming at personal customization requirements. Methods. First to build the compact RC model of tissue BG through impedance precision measuring Kit, then to simulate and soft-test BG by Boolean chaotic Codec circuits in soft tool Multisim 13.0, The third to capture the chaotic decoding outputs with the Kit plus PC in calculated signatures of resistor and phase of the tested impedance at the subjects’ left wrist in synchronous test by Bayer BG meter. Results. All in controlled trials of Bayer BG meter, the chaotic BG modelling had gained three new compared formulae in merits of errors less than 1mmol/L and latency less than 1minute. Conclusion. During further verification of this chaotic test paradigm, the opened logic route of above methods will boost measurement experts’ confidence in overcoming future problems of blood glucose monitoring in vivo.

  20. Measurements of radon concentrations at caves in Jeju

    Energy Technology Data Exchange (ETDEWEB)

    Go, S. H.; Kang, D. H.; Jung, B. J. [Cheju National University, Cheju (Korea, Republic of)

    2004-07-01

    Radon is a radioactive gas emitting {alpha} particles. It is chemically stable due to its inert characteristic. While its daughter products, {sup 218}Po, {sup 214}Bi, {sup 214}Pb and {sup 214}Po, attached with aerosol particles, is known to cause lung cancer. As radon is produced from uranium and thorium, it accumulates in poorly ventilative underground voids such as caves and mine. Radon concentrations at caves in Jeju were measured in this study. The measurements were made by setting three CR-39 detectors for 70 days at 2 {approx} 4 positions in Manjang, Hyupjae and Ssangyong caves. The radon levels of the caves spread 403.1 . 606.7 Bq/m{sup 3}. With these results, it is concluded that the Jeju caves have 6 times higher radon concentrations than ordinary house of 65.3 Bq/m{sup 3} and that they are higher than Seoul subway stations due to poor ventilation. While, the caves in Jeju have lower radon concentrations than limestone caves of Robin Hood. The radon concentration in the middle of Manjang cave is slightly higher than the action level in the work place of 500 Bq/m{sup 3} suggested by the ICRP. The measurement errors are estimated to be less than 5 % from its calibration factor.

  1. Measurements of radon concentrations at caves in Jeju

    International Nuclear Information System (INIS)

    Go, S. H.; Kang, D. H.; Jung, B. J.

    2004-01-01

    Radon is a radioactive gas emitting α particles. It is chemically stable due to its inert characteristic. While its daughter products, 218 Po, 214 Bi, 214 Pb and 214 Po, attached with aerosol particles, is known to cause lung cancer. As radon is produced from uranium and thorium, it accumulates in poorly ventilative underground voids such as caves and mine. Radon concentrations at caves in Jeju were measured in this study. The measurements were made by setting three CR-39 detectors for 70 days at 2 ∼ 4 positions in Manjang, Hyupjae and Ssangyong caves. The radon levels of the caves spread 403.1 . 606.7 Bq/m 3 . With these results, it is concluded that the Jeju caves have 6 times higher radon concentrations than ordinary house of 65.3 Bq/m 3 and that they are higher than Seoul subway stations due to poor ventilation. While, the caves in Jeju have lower radon concentrations than limestone caves of Robin Hood. The radon concentration in the middle of Manjang cave is slightly higher than the action level in the work place of 500 Bq/m 3 suggested by the ICRP. The measurement errors are estimated to be less than 5 % from its calibration factor

  2. Measurement and COrrelation on Viscosity and Apparent Molar Volume of Ternary System for L—ascorbic Acid in Aqueous D—Glucose and Sucrose Solutions

    Institute of Scientific and Technical Information of China (English)

    赵长伟; 马沛生

    2003-01-01

    Visosities and densities at ,several temperatures from 293.15 K to 313.15K are reported for L-ascorbic acid in aqueous glucose and sucrose solutions at different concentrations.The parameters of density,Viscosity coefficient B and partial molar volume are calculated by regression.The experimental results show that densities and viscositis decrease as temperature increases at the same solute and solvent (glucose and sucrose aueous solution)concentrations,and increase with concentration of glucose and sucrose at the same solute concentration and temperature,B increases with concentration of glucose and sucrose and temaperature,L-ascorbic acid is sturcture-breaker or structure-making for the glucose and sucrose aqueous solutions ,Furthermore,the solute-solvent interactions in ternary systems of water-glucose-electrolyte and water-sucrose-electrolyte are discussed.

  3. Measurement of the concentration of radon in the air

    International Nuclear Information System (INIS)

    Aten, J.B.Th.; Bierhuizen, H.W.J.; Hoek, L.P. van; Ros, D.; Weber, J.

    1975-01-01

    A simple transportable air monitoring apparatus was developed for controlling the radon contamination of air in laboratory rooms. It is not highly accurate but is sufficient to register the order of magnitude of the radon concentration. Air is pumped through a filter for one or two hours and an alpha decay curve of the dust on the filter is determined. Scintillation counting forty minutes after sampling indicates the radon activity. The calibration method of measuring the equilibrium of daughter product concentrations is discussed extensively

  4. Measurement of Alpha Emitters Concentration in Imported Cigarettes

    International Nuclear Information System (INIS)

    Nasser Allah, Z.K.; Musa, W.A.; AL-Rawi, A.A.S.

    2011-01-01

    The aime of this study was to measured the alpha emitters concentration of (15) different kinds of imported cigarettes. the nuclear reaction used U-235(n, f) obtained by the bombardment of U-235 with thermal neutrons from (Am B e)neutron source with thermal flux of(5*10 3 n.cm -2 .s -1 ). The Results obtained showed the values of the Uranium concentration, and varies from (0.041 ppm) in five stares kind to (2.374ppm) in Machbeth (chocolate) 100's kind. All the result obtained are within the limit levels as given by UNSCAR data

  5. Monitoring and measurement of oxygen concentrations in liquid sodium

    International Nuclear Information System (INIS)

    Smith, D.L.

    1976-01-01

    The measurement of oxygen concentrations in sodium at levels of interest for LMFBR applications is reviewed. Additional data are presented to support the validity of the vanadium-equilibration method as a reference for determination of oxygen concentrations in sodium at levels equal to or less than 15 ppM. Operating experience with electrochemical oxygen meters that have a thoria-yttria electrolyte and a Na--Na 2 O reference electrode is described. Meter lifetimes in excess of one year have generally been achieved for operating temperatures of 352 and 402 0 C, and fairly stable emfs have been observed for periods of several months. 7 fig, 21 references

  6. Measurement of radon concentration in air employing Lucas chamber

    International Nuclear Information System (INIS)

    Machaj, B.

    1997-01-01

    The results of investigations aimed to determine the main features of radon concentration gauge in air, employing 0.17 L Lucas chamber, and air sample forced by an air pump are presented. For two hour sampling and measuring cycle time the dynamic error in the worst case (first read out) equals 5 % relative to the step jump of radon concentration. This is due to the increase of activity of the decay products in the chamber. It was observed that the short lived radon decay products (Po-218, Pb-214, Bi-214) are depositing on the walls of the chamber and they are not removed by flushing the chamber with air. (author)

  7. Regional cerebral glucose consumption measured by positron emission tomography in patients with Wilson's disease

    International Nuclear Information System (INIS)

    Kuwert, T.; Scholz, D.; Milz, M.; Herzog, H.; Feinendegen, L.E.; Hefter, H.; Weiss, P.; Arendt, G.; Loken, M.; Minnesota Univ., Minneapolis, MN; Hennerici, M.

    1992-01-01

    Using positron emission tomography (PET), the regional cerebral metabolic rate of glucose consumption (rCMRGlc) was measured in 14 patients with Wilson's disease (WD) and 23 normal subjects. In WD patients, cerebellar, striatal and - to a lesser extent - cortical and thalamic rCMRGlc were significantly decreased compared with controls. Striatal rCMRGlc was significantly reduced in those 4 patients who had recently started decoppering therapy as compared with striatal rCMRGlc measured in those 10 patients with longer duration of medication. Caudate rCMRGlc correlated significantly with various signs of extrapyramidal dysfunction. Cerebellar, thalamic and cortical rCMRGlc correlated significantly with the severity of pyramidal signs. These data indicate that the PET measurement of rCMRGlc may be a useful tool to evaluate cerebral involvement in WD and to monitor the response to treatment. (orig.)

  8. PENGARUH DIET KACANG MERAH TERHADAP KADAR GULA DARAH TIKUS DIABETIK INDUKSI ALLOXAN [Effect of Red Bean Diet on Blood Glucose Concentration of Alloxan-Induced Diabetic Rats

    Directory of Open Access Journals (Sweden)

    Y. Marsono 1

    2003-04-01

    Full Text Available Hypoglycemic response of red bean were evaluated in alloxan-induced diabetic rats. The objective of this research was to evaluate the effect of red bean (Vigna umbellata diet compare with soy bean diet on blood glucose concentration in alloxan-induced diabetic rats.Thirty male Sprague-Dawley (SD rats (250-300 g were diabetic induced by alloxan injection (80 mg/kg of body weight by intra muscular injection. They were divided into three groups of ten rats. They were fed (1 Standard diet (STD, (2 Red bean diet (KM, and (3 Soy bean diet (KD for 28 days. Concentration of serum glucose were determined before injection (0 day,after injection (day 17th and every sweek during diet intervention (day 24,31,38 and 45thIt was found that alloxan injection increased serum glucose concentration of STD, KM, and KD rats. After 28 days intervention, red bean decreased the serum glucose concentration from 217, 87 mg/dL to 57,70 mg/dL (69 % in KM groups and from 218,94 mg/dL to 76,82 mg/dL (65 % in KD groups, but standard diet (STD were decreased less than both of KM and KD diet.

  9. Method and device for measuring the smoke concentration in air

    International Nuclear Information System (INIS)

    Rennemo, B.

    1994-01-01

    The patent deals with a method and a device for measuring the smoke concentration in air. In a smoke chamber are located two electrodes, connected to a voltage source for forming a circuit in which a DC current flows. A radioactive radiation source to ionize the air molecules is located in the vicinity of the smoke chamber, so that the number of ionized air molecules which are formed is dependent upon the radiation intensity of the ion source and the concentration of smoke particles in the smoke chamber. The charging voltage will further imply that a cloud of high ion concentration is built up close to the surface of the electrodes. The ion cloud will be discharged capacitively upon a plurality of short voltages pulses applied to the electrodes to thereby result in current pulses substantially greater than the DC current flowing through the chamber. 8 figs

  10. Diagnostics of and measures against radon concentrations in a dwelling

    International Nuclear Information System (INIS)

    Berger, H.

    1994-02-01

    Results are presented of measurements in a test-dwelling in the period april 1993 - november 1993. The purpose of the measurements was to investigate the possibilities of using a blower door (a fan in a wall of the dwelling) for specifying sources of radon in the dwelling, employing the diagnostic method developed at the KVI (Nuclear Physics Accelerator Institute in Groningen, Netherlands). Special attention is paid to the measurement of two input variables for the diagnostic method: transparency of the walls of the dwelling and the strength of static sources. Also measures aimed at reducing radon concentrations in the dwelling are discussed. The main conclusions are that (a) the pressure-variation method is a valid procedure to measure the transparency of walls and floors; (b) the blower door is a suitable technique for arriving at a correct diagnosis; and (c) over-pressurizing the crawl-space is the most effective measure in reducing the radon concentration of the crawl-space. More research on air flows in the soil is recommended. 21 figs., 28 tabs., 7 refs

  11. Elevated glucose concentrations promote receptor-independent activation of adherent human neutrophils: an experimental and computational approach

    DEFF Research Database (Denmark)

    Kummer, Ursula; Zobeley, Jürgen; Brasen, Jens Christian

    2007-01-01

    of NO and superoxide formation were observed. However, these changes were not observed for sorbitol, a nonmetabolizable carbohydrate. Glucose transport appears to be important in this process as phloretin interferes with the glucose-specific receptor-independent activation of neutrophils. However, LY83583...

  12. Glucose allostasis

    DEFF Research Database (Denmark)

    Stumvoll, Michael; Tataranni, P Antonio; Stefan, Norbert

    2003-01-01

    individuals with normal glucose tolerance, normoglycemia can always be maintained by compensatorily increasing AIR in response to decreasing M (and vice versa). This has been mathematically described by the hyperbolic relationship between AIR and M and referred to as glucose homeostasis, with glucose......In many organisms, normoglycemia is achieved by a tight coupling of nutrient-stimulated insulin secretion in the pancreatic beta-cell (acute insulin response [AIR]) and the metabolic action of insulin to stimulate glucose disposal (insulin action [M]). It is widely accepted that in healthy...... concentration assumed to remain constant along the hyperbola. Conceivably, glucose is one of the signals stimulating AIR in response to decreasing M. Hypothetically, as with any normally functioning feed-forward system, AIR should not fully compensate for worsening M, since this would remove the stimulus...

  13. Optimized methods to measure acetoacetate, 3-hydroxybutyrate, glycerol, alanine, pyruvate, lactate and glucose in human blood using a centrifugal analyser with a fluorimetric attachment.

    Science.gov (United States)

    Stappenbeck, R; Hodson, A W; Skillen, A W; Agius, L; Alberti, K G

    1990-01-01

    Optimized methods are described for the analysis of glucose, lactate, pyruvate, alanine, glycerol, D-3-hydroxybutyrate and acetoacetate in perchloric acid extracts of human blood using the Cobas Bio centrifugal analyser. Glucose and lactate are measured using the photometric mode and other metabolites using the fluorimetric mode. The intra-assay coefficients of variation ranged from 0.7 to 4.1%, except with very low levels of pyruvate and acetoacetate where the coefficients of variation were 7.1 and 12% respectively. All seven metabolites can be measured in a perchloric acid extract of 20 mul of blood. The methods have been optimized with regard to variation in the perchloric acid content of the samples. These variations arise from the method of sample preparation used to minimize changes occurring in metabolite concentration after venepuncture.

  14. Measuring Low Concentrations of Liquid Water in Soil

    Science.gov (United States)

    Buehler, Martin

    2009-01-01

    An apparatus has been developed for measuring the low concentrations of liquid water and ice in relatively dry soil samples. Designed as a prototype of instruments for measuring the liquidwater and ice contents of Lunar and Martian soils, the apparatus could also be applied similarly to terrestrial desert soils and sands. The apparatus is a special-purpose impedance spectrometer: Its design is based on the fact that the electrical behavior of a typical soil sample is well approximated by a network of resistors and capacitors in which resistances decrease and capacitances increase (and, hence, the magnitude of impedance decreases) with increasing water content.

  15. Apparatus for measuring the concentration of a gas

    International Nuclear Information System (INIS)

    Manin, Ange.

    1974-01-01

    The apparatus described for measuring the concentration of a gas in an atmosphere is of the kind which has an ionization chamber with an internal radioactive source and associated electronics enabling the ionization current crossing the chamber to be measured. It includes at least one cylindrical metal grid forming an electrode brought to a high voltage in relation to a cylindrical collection electrode fitted to the axis of the grid coated with a radioactive deposit and, around this grid, a screen acting as a protective envelope. The radioactive deposit is tritiated titanium [fr

  16. Laser metrology in fluid mechanics granulometry, temperature and concentration measurements

    CERN Document Server

    Boutier, Alain

    2013-01-01

    In fluid mechanics, non-intrusive measurements are fundamental in order to improve knowledge of the behavior and main physical phenomena of flows in order to further validate codes.The principles and characteristics of the different techniques available in laser metrology are described in detail in this book.Velocity, temperature and concentration measurements by spectroscopic techniques based on light scattered by molecules are achieved by different techniques: laser-induced fluorescence, coherent anti-Stokes Raman scattering using lasers and parametric sources, and absorption sp

  17. Measurement of indoor radon concentration by CR-39 track detector

    International Nuclear Information System (INIS)

    Yamamoto, Masayoshi; Yoneda, Shigeru; Nakanishi, Takashi.

    1990-01-01

    A convenient and cheap method for measuring indoor radon ( 222 Rn) concentration with a CR-39 track detector is described. The detector consisted of two sheets of CR-39 enclosed separately in two plastic pots : one covered by a filter (cup method) and another no covering (bare method). The bare method was used here to supplement the cup method. To compare with the result of the CR-39 detector, alpha-ray spectrometry was carried out with a Si(Au) detector in a controlled radon exposure chamber. Indoor radon concentration measured in 133 houses in several districts of Ishikawa Prefecture have been found to range from 6 Bq/m 3 to as high as 113 Bq/m 3 with a median value of 24 Bq/m 3 . The problems to measure indoor radon concentration using the CR-39 detector are also discussed with emphasis on the position of setting the detector in the room and the possible thoron contribution to the detector. (author)

  18. Agmatine protects Müller cells from high-concentration glucose-induced cell damage via N-methyl-D-aspartic acid receptor inhibition.

    Science.gov (United States)

    Han, Ning; Yu, Li; Song, Zhidu; Luo, Lifu; Wu, Yazhen

    2015-07-01

    Neural injury is associated with the development of diabetic retinopathy. Müller cells provide structural and metabolic support for retinal neurons. High glucose concentrations are known to induce Müller cell activity. Agmatine is an endogenous polyamine, which is enzymatically formed in the mammalian brain and has exhibited neuroprotective effects in a number of experimental models. The aims of the present study were to investigate whether agmatine protects Müller cells from glucose-induced damage and to explore the mechanisms underlying this process. Lactate dehydrogenase activity and tumor necrosis factor-α mRNA expression were significantly reduced in Müller cells exposed to a high glucose concentration, following agmatine treatment, compared with cells not treated with agmatine. In addition, agmatine treatment inhibited glucose-induced Müller cell apoptosis, which was associated with the regulation of Bax and Bcl-2 expression. Agmatine treatment suppressed glucose-induced phosphorylation of mitogen-activated protein kinase (MAPK) protein in Müller cells. The present study demonstrated that the protective effects of agmatine on Müller cells were inhibited by N-methyl-D-aspartic acid (NMDA). The results of the present study suggested that agmatine treatment protects Müller cells from high-concentration glucose-induced cell damage. The underlying mechanisms may relate to the anti-inflammatory and antiapoptotic effects of agmatine, as well as to the inhibition of the MAPK pathway, via NMDA receptor suppression. Agmatine may be of use in the development of novel therapeutic approaches for patients with diabetic retinopathy.

  19. Accuracy of bedside glucose measurement from three glucometers in critically ill patients.

    NARCIS (Netherlands)

    Hoedemaekers, C.W.E.; Klein Gunnewiek, J.M.T.; Prinsen, M.A.; Willems, J.L.; Hoeven, J.G. van der

    2008-01-01

    OBJECTIVE: Implementation of strict glucose control in most intensive care units has resulted in increased use of point-of-care glucose devices in the intensive care unit. The aim of this study was to determine the reliability of point-of-care testing glucose meters among critically ill patients

  20. Radon concentration measurements in waters in Greece and Cyprus

    International Nuclear Information System (INIS)

    Louizi, A.; Nikolopoulos, D.; Tzortzi, A.; Thanassas, D.; Serefoglou, A.; Georgiou, E.; Vogiannis, E.; Koukouliou, V.

    2004-01-01

    The radon content of drinking water samples was determined with Alpha Guard Pro equipped with an appropriate unit (Aqua Kit). The samples were collected from water taps in dwellings located at various cities in Greece and Cyprus. In addition, surface water samples from rivers, lakes and seas as well as potable underground and hot spring water samples from Greece and Cyprus were also collected. For a precise determination of radon concentration in water samples, special procedures were followed both for sampling and transportation, as well as for measurement. Intercomparison experiments were designed and implemented before and during the study. Radon concentrations in drinking water samples in Greece ranged between 1.1 ± 0.5 Bq/L and 410±50 Bq/L. The corresponding concentrations in Cyprus ranged between 1.3 ± 0.8 Bq/L and 15±4 Bq/L. Three samples collected from the city of Arnea Chalkidikis (Northern Greece) exhibited high concentrations of 120±20 Bq/L, 320±40 Bq/L and 410±50 Bq/L. This city is identified as a high radon potential area. One water sample located in Lesvos Island (North-East part of Greece) exhibited radon concentration 140±20 Bq/L. Additional six samples displayed high concentrations in potable hot spring water samples. These samples which were collected from the city of Loutraki (Peloponnesus) ranged between 220-230 Bq/L. In addition, two samples characterized as 'medicinal drinking water' gave concentrations between 320 Bq/L and 340 Bq/L. For underground water samples the radon concentrations ranged between 1.2±0.7 Bq/L and 15±4 Bq/L, while for surface water samples the range was 2.7±0.8 Bq/L to 24±6 Bq/L. The observed concentrations of radon gas in potable water samples in Greece were found to be largely low. In Cyprus, they were all well below 15 Bq/L

  1. Measurement of plasma adenosine concentration: methodological and physiological considerations

    International Nuclear Information System (INIS)

    Gewirtz, H.; Brown, P.; Most, A.S.

    1987-01-01

    This study tested the hypothesis that measurements of plasma adenosine concentration made on samples of blood obtained in dipyridamole and EHNA (i.e., stopping solution) may be falsely elevated as a result of ongoing in vitro production and accumulation of adenosine during sample processing. Studies were performed with samples of anticoagulated blood obtained from anesthesized domestic swine. Adenosine concentration of ultra filtrated plasma was determined by HPLC. The following parameters were evaluated: (i) rate of clearance of [ 3 H]adenosine added to plasma, (ii) endogenous adenosine concentration of matched blood samples obtained in stopping solution alone, stopping solution plus EDTA, and perchloric acid (PCA), (iii) plasma and erythrocyte endogenous adenosine concentration in nonhemolyzed samples, and (iv) plasma adenosine concentration of samples hemolyzed in the presence of stopping solution alone or stopping solution plus EDTA. We observed that (i) greater than or equal to 95% of [ 3 H]adenosine added to plasma is removed from it by formed elements of the blood in less than 20 s, (ii) plasma adenosine concentration of samples obtained in stopping solution alone is generally 10-fold greater than that of matched samples obtained in stopping solution plus EDTA, (iii) deliberate mechanical hemolysis of blood samples obtained in stopping solution alone resulted in substantial augmentation of plasma adenosine levels in comparison with matched nonhemolyzed specimens--addition of EDTA to stopping solution prevented this, and (iv) adenosine content of blood samples obtained in PCA agreed closely with the sum of plasma and erythrocyte adenosine content of samples obtained in stopping solution plus EDTA

  2. Influence of Partial Pressure of Oxygen in Blood Samples on Measurement Performance in Glucose-Oxidase-Based Systems for Self-Monitoring of Blood Glucose

    Science.gov (United States)

    Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Haug, Cornelia; Freckmann, Guido

    2013-01-01

    Background Partial pressure of oxygen (pO2) in blood samples can affect blood glucose (BG) measurements, particularly in systems that employ the glucose oxidase (GOx) enzyme reaction on test strips. In this study, we assessed the impact of different pO2 values on the performance of five GOx systems and one glucose dehydrogenase (GDH) system. Two of the GOx systems are labeled by the manufacturers to be sensitive to increased blood oxygen content, while the other three GOx systems are not. Methods Aliquots of 20 venous samples were adjusted to the following pO2 values: pO2 ~70 mmHg, which is considered to be similar to pO2 in capillary blood samples, and the mean BG result at pO2 pO2 pO2 ≥150 mmHg. For both pO2 levels, relative differences of all tested GOx systems were significant (p pO2 values pO2 variations lead to clinically relevant BG measurement deviations in GOx systems, even in GOx systems that are not labeled as being oxygen sensitive. PMID:24351177

  3. Glucose kinetics in infants of diabetic mothers

    International Nuclear Information System (INIS)

    Cowett, R.M.; Susa, J.B.; Giletti, B.; Oh, W.; Schwartz, R.

    1983-01-01

    Glucose kinetic studies were performed to define the glucose turnover rate with 78% enriched D-[U-13C] glucose by the prime constant infusion technique at less than or equal to 6 hours of age in nine infants of diabetic mothers (four insulin-dependent and five chemical diabetic patients) at term. Five normal infants were studied as control subjects. All infants received 0.9% saline intravenously during the study with the tracer. Fasting plasma glucose, insulin, and glucose13/12C ratios were measured during the steady state, and the glucose turnover rate was derived. The average plasma glucose concentration was similar during the steady state in the infants of the diabetic mothers and in the control infants, and the glucose turnover rate was not significantly different among the groups: 2.3 +/- 0.6 mg . kg-1 min-1 in infants of insulin-dependent diabetic patients; 2.4 +/- 0.4 mg . kg-1 min-1 in infants of chemical diabetic patients; and 3.2 +/- 0.3 mg . kg-1 min-1 in the control subjects. Good control of maternal diabetes evidenced by the normal maternal hemoglobin A1c and plasma glucose concentration at delivery and cord plasma glucose concentration resulted in glucose kinetic values in the infants of diabetic mothers that were indistinguishable from those of control subjects. The data further support the importance of good control of the diabetic state in the pregnant woman to minimize or prevent neonatal hypoglycemia

  4. The influence of Bauhinia forficata Link subsp. pruinosa tea on lipid peroxidation and non-protein SH groups in human erythrocytes exposed to high glucose concentrations.

    Science.gov (United States)

    Salgueiro, Andréia C F; Leal, Carina Q; Bianchini, Matheus C; Prado, Ianeli O; Mendez, Andreas S L; Puntel, Robson L; Folmer, Vanderlei; Soares, Félix A; Avila, Daiana S; Puntel, Gustavo O

    2013-06-21

    Bauhinia forficata (BF) has been traditionally used as tea in folk medicine of Brazil for treatment of Diabetes mellitus (DM). To evaluate the effects of BF leaf tea on markers of oxidative damage and antioxidant levels in an experimental model of hyperglycemia in human erythrocytes in vitro. Human erythrocytes were incubated with high glucose concentrations or glucose and BF tea for 24h and 48h. After incubation lipid peroxidation and non-protein SH levels were analyzed. Moreover, quantification of polyphenols and flavonoids, iron chelating property, scavenging of DPPH, and prevention of lipid peroxidation in isolated lipids were also assessed. A significant amount of polyphenols and flavonoids was observed. The main components found by LC-MS analysis were quercetin-3-O-(2-rhamnosyl) rutinoside, kaempferol-3-O-(2-rhamnosyl) rutinoside, quercetin-3-O-rutinoside and kaempferol-3-O-rutinoside. BF tea presents important antioxidant and chelating properties. Moreover, BF tea was effective to increase non-protein SH levels and reduce lipid peroxidation induced by high glucose concentrations in human erythrocytes. The antioxidant effects of BF tea could be related to the presence of different phenolic and flavonoids components. We believe that these components can be responsible to protect human erythrocytes exposed to high glucose concentrations against oxidative damage. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  5. Development of a scale to measure adherence to self-monitoring of blood glucose with latent variable measurement.

    Science.gov (United States)

    Wagner, J A; Schnoll, R A; Gipson, M T

    1998-07-01

    Adherence to self-monitoring of blood glucose (SMBG) is problematic for many people with diabetes. Self-reports of adherence have been found to be unreliable, and existing paper-and-pencil measures have limitations. This study developed a brief measure of SMBG adherence with good psychometric properties and a useful factor structure that can be used in research and in practice. A total of 216 adults with diabetes responded to 30 items rated on a 9-point Likert scale that asked about blood monitoring habits. In part I of the study, items were evaluated and retained based on their psychometric properties. The sample was divided into exploratory and confirmatory halves. Using the exploratory half, items with acceptable psychometric properties were subjected to a principal components analysis. In part II of the study, structural equation modeling was used to confirm the component solution with the entire sample. Structural modeling was also used to test the relationship between these components. It was hypothesized that the scale would produce four correlated factors. Principal components analysis suggested a two-component solution, and confirmatory factor analysis confirmed this solution. The first factor measures the degree to which patients rely on others to help them test and thus was named "social influence." The second component measures the degree to which patients use physical symptoms of blood glucose levels to help them test and thus was named "physical influence." Results of the structural model show that the components are correlated and make up the higher-order latent variable adherence. The resulting 15-item scale provides a short, reliable way to assess patient adherence to SMBG. Despite the existence of several aspects of adherence, this study indicates that the construct consists of only two components. This scale is an improvement on previous measures of adherence because of its good psychometric properties, its interpretable factor structure, and its

  6. Measurement of indoor and outdoor radon concentrations during Superstorm Sandy.

    Science.gov (United States)

    Kotrappa, Payasada; Paul, Prateek; Stieff, Alex; Stieff, Frederick

    2013-12-01

    Superstorm Sandy affected much of the US East Coast extending over 1800 km. It passed over the test location in the State of Maryland on 29 October 2012. Being 350 km away from the regions of highest intensity the storm was of lower intensity at the test location. Continuous radon monitors and passive radon monitors were used for the measurement. The test location was the basement of a single family home representing the indoor concentration. A partially opened garage of the same test home represented the outdoor radon concentration. In 24 h, the atmospheric pressure dropped from 990 to 960 mbar and the indoor radon concentration increased from 70 to 1500 Bq m(-3) and returned to the normal of 70 Bq m(-3) at the end of the storm. Throughout the storm, the outdoor radon concentration was not significantly affected. Probable reasons for such surprisingly large changes are discussed. However, the outdoor temperature dropped from 13°C to 7°C during the radon peak.

  7. Integrating measurements of indoor thoron and its progeny concentrations

    International Nuclear Information System (INIS)

    Zhuo, W.H.; Iida, T.; Hashiguchi, Y.

    2000-01-01

    In recent years, indoor surveys in Europe and Asia revealed that the dose contribution from thoron and its progeny can equal or even exceed that of radon and its progeny. For measuring thoron and its progeny, several methods had been reported. However, convenient, low-cost and time-integrating measuring methods which are suitable for large-scale surveys are still unavailable. To solve this problem, three integrating measuring methods with allyl diglycol carbonate plastic (CR-39) as detectors have recently been. The results indicated that they are suitable for estimating the indoor thoron and its progeny concentrations when the public exposure to thoron and its progeny is taken into account. Cup monitor - Former types of passive integrating 222 Rn and 220 Rn cup monitors had been reported. Recently, in order to improve the sensitivity of thoron detection, the air exchange rate between the inner and outer cup was enhanced, and the radius of the hemisphere was reduced to 37.5 mm. Furthermore, the procedure of detector exchange was made to be more convenient. Equilibrium-equivalent 222 Rn and 220 Rn concentrations monitor (EEC monitor) - The measuring system is composed of a monitor head and a diaphragm pump. The total weight of the system is less than 1.5 kg, which makes it portable. The construction of the monitor head and the measuring principle were also reported by the authors. Thoron progeny deposition rate monitor - The monitor is simply constituted a piece of CR-39 covered with thin sheets of absorbers. The thickness of the absorbers are adjusted to let only the α particles emitted from 212 Pb impinge on the detector. The concentrations of thoron progeny are estimated from the deposition rates, assuming that the deposition velocities of thoron progeny are constant in general dwellings. The improved cup monitor has higher sensitivity than former monitors, with a calibration factor of 1.59x10 -3 tracks·cm -2 (Bq·m -3 ·h) -1 for thoron. The accuracy of the ECC

  8. Measurements of urea and glucose in aqueous solutions with dual-beam near-infrared Fourier-transform spectroscopy

    DEFF Research Database (Denmark)

    Jensen, P.S.; Bak, J.

    2002-01-01

    of these two modes of operation. The concentrations of aqueous solutions of urea and glucose in the ranges 0-40 mg/dL and 0-250 mg/dL, respectively, were determined by principal component regression using both modes. The dual-beam technique eliminated instrumental variations present in the single...

  9. [The research of near-infrared blood glucose measurement using particle swarm optimization and artificial neural network].

    Science.gov (United States)

    Dai, Juan; Ji, Zhong; Du, Yubao

    2017-08-01

    Existing near-infrared non-invasive blood glucose detection modelings mostly detect multi-spectral signals with different wavelength, which is not conducive to the popularization of non-invasive glucose meter at home and does not consider the physiological glucose dynamics of individuals. In order to solve these problems, this study presented a non-invasive blood glucose detection model combining particle swarm optimization (PSO) and artificial neural network (ANN) by using the 1 550 nm near-infrared absorbance as the independent variable and the concentration of blood glucose as the dependent variable, named as PSO-2ANN. The PSO-2ANN model was based on two sub-modules of neural networks with certain structures and arguments, and was built up after optimizing the weight coefficients of the two networks by particle swarm optimization. The results of 10 volunteers were predicted by PSO-2ANN. It was indicated that the relative error of 9 volunteers was less than 20%; 98.28% of the predictions of blood glucose by PSO-2ANN were distributed in the regions A and B of Clarke error grid, which confirmed that PSO-2ANN could offer higher prediction accuracy and better robustness by comparison with ANN. Additionally, even the physiological glucose dynamics of individuals may be different due to the influence of environment, temper, mental state and so on, PSO-2ANN can correct this difference only by adjusting one argument. The PSO-2ANN model provided us a new prospect to overcome individual differences in blood glucose prediction.

  10. Alterations in blood glucose and plasma glucagon concentrations during deep brain stimulation in the shell region of the nucleus accumbens in rats

    Directory of Open Access Journals (Sweden)

    Charlene eDiepenbroek

    2013-12-01

    Full Text Available Deep brain stimulation (DBS of the nucleus accumbens (NAc is an effective therapy for obsessive compulsive disorder (OCD and is currently under investigation as a treatment for eating disorders. DBS of this area is associated with altered food intake and pharmacological treatment of OCD is associated with the risk of developing type 2 diabetes. Therefore we examined if DBS of the NAc-shell (sNAc influences glucose metabolism. Male Wistar rats were subjected to DBS, or sham stimulation, for a period of one hour. To assess the effects of stimulation on blood glucose and glucoregulatory hormones, blood samples were drawn before, during and after stimulation. Subsequently, all animals were used for quantitative assessment of Fos immunoreactivity in the lateral hypothalamic area (LHA using computerized image analysis. DBS of the sNAc rapidly increased plasma concentrations of glucagon and glucose while sham stimulation and DBS outside the sNAc were ineffective. In addition, the increase in glucose was dependent on DBS intensity. In contrast, the DBS-induced increase in plasma corticosterone concentrations was independent of intensity and region, indicating that the observed DBS-induced metabolic changes were not due to corticosterone release. Stimulation of the sNAc with 200 μA increased Fos immunoreactivity in the LHA compared to sham or 100 μA stimulated animals. These data show that DBS of the sNAc alters glucose metabolism in a region- and intensity dependent manner in association with neuronal activation in the LHA. Moreover, these data illustrate the need to monitor changes in glucose metabolism during DBS-treatment of OCD patients.

  11. 'I try not to bother the residents too much' - the use of capillary blood glucose measurements in nursing homes.

    Science.gov (United States)

    Andreassen, Lillan Mo; Granas, Anne Gerd; Sølvik, Una Ørvim; Kjome, Reidun Lisbet Skeide

    2016-01-01

    Capillary blood glucose measurements are regularly used for nursing home residents with diabetes. The usefulness of these measurements relies on clear indications for use, correct measurement techniques, proper documentation and clinical use of the resulting blood glucose values. The use of a regular, invasive procedure may also entail additional challenges in a population of older, multimorbid patients who often suffer from cognitive impairment or dementia. The aim of this study was to explore the perspectives of physicians, registered nurses and auxiliary nurses on the use, usefulness and potential challenges of using capillary blood glucose measurements in nursing homes, and the procedures for doing so. This was a qualitative study that used three profession-specific focus group interviews. Interviews were transcribed in modified verbatim form and analysed in accordance with Malterud's principles of systematic text condensation. Five physicians, four registered nurses and three auxiliary nurses participated in the focus groups. All professional groups regarded capillary blood glucose measurements as a necessity in the management of diabetes, the physicians to ensure that the treatment is appropriate, and the nurses to be certain and assured about their caring decisions. Strict glycaemic control and excessive measurements were avoided in order to promote the well-being and safety of the residents. Sufficient knowledge of diabetes symptoms, equivalent practices for glucose measurement, and unambiguous documentation and communication of results were determined to be most helpful. However, all professional groups seldom involved the residents in managing their own measurements and stated that guidelines and training had been inconsistent or lacking. Inadequate procedures and training in diabetes care may compromise the rationale for capillary blood glucose measurements in nursing homes, and hence the residents' safety. These concerns should be addressed together

  12. Proinflammatory Effect of High Glucose Concentrations on HMrSV5 Cells via the Autocrine Effect of HMGB1

    Directory of Open Access Journals (Sweden)

    Yuening Chu

    2017-09-01

    Full Text Available Background: Peritoneal fibrosis, in which inflammation and apoptosis play crucial pathogenic roles, is a severe complication associated with the treatment of kidney failure with peritoneal dialysis (PD using a glucose-based dialysate. Mesothelial cells (MCs take part in the inflammatory processes by producing various cytokines and chemokines, such as monocyte chemoattractant protein 1 (MCP-1 and interleukin 8 (IL-8. The apoptosis of MCs induced by high glucose levels also contributes to complications of PD. High mobility group protein B1 (HMGB1 is an inflammatory factor that has repeatedly been proven to be related to the occurrence of peritoneal dysfunction.Aim: In this study, we aimed to explore the effect and underlying mechanism of endogenous HMGB1 in high-glucose-induced MC injury.Methods: The human peritoneal MC line, HMrSV5 was cultured in high-glucose medium and incubated with recombinant HMGB1. Cellular expression of HMGB1 was blocked using HMGB1 small interfering RNA (siRNA. Apoptosis and production of inflammatory factors as well as the potential intermediary signaling pathways were examined.Results: The major findings of these analyses were: (1 MCs secreted HMGB1 from the nucleus during exposure to high glucose levels; HMGB1 acted in an autocrine fashion on the MCs to promote the production of MCP-1 and IL-8; (2 HMGB1 had little effect on high-glucose-induced apoptosis of the MCs; and (3 HMGB1-mediated MCP-1 and IL-8 production depended on the activation of MAPK signaling pathways. In conclusion, endogenous HMGB1 plays an important role in the inflammatory reaction induced by high glucose on MCs via mitogen-activated protein kinase (MAPK signaling pathways, but it seems to have little effect on high-glucose-induced apoptosis.

  13. Measurements of serum-free thyroid hormone concentrations by ultrafiltration

    International Nuclear Information System (INIS)

    Konno, Norimichi; Hagiwara, Kohji; Taguchi, Hideo; Murakami, Shigeki; Taguchi, Shizuko

    1987-01-01

    An ultrafiltration method (UF) for measuring free thyroxine (FT 4 ) and free triiodothyronine (FT 3 ) using the Diaflow YM membrane (Centricon-10) is described. The results are compared with those by equilibrium dialysis (ED) and also by mathematical calculations derived from T 4 , T 3 , and binding protein concentrations. The precision with the UF method was excellent. The normal ranges of FT 4 and FT 3 by the three methods are all comparable. There was a high degree of correlation of FT 4 or FT 3 results by UF with those by ED and by calculation (r = 0.940 - 0.974, n = 161, P 4 and FT 3 by all methods agreed well for hyperthyroidism, hypothyroidism, and for patients with low T 4 -binding globulin. The mean FT 3 in pregnancy was lower than the normal value for all methods, and FT 4 concentrations by UF and calculation also decreased in late pregnancy. The mean FT 4 by UF and ED in low T 3 syndrome were significantly higher than in the normal controls, while the calculated FT 4 was lower. The FT 3 in low T 3 syndrome distributed normal to subnormal in all methods. These results indicate that a) the UF method is a reliable reference method for measuring FT 4 and FT 3 concentrations; b) the UF results agree well with those by ED and also with theoretically derived values in subjects with thyroid diseases and TBG abnormalities; c) for patients with low T 3 syndrome, the FT 4 results obtained by UF and ED are similarly discrepant from the calculated results, implying the existence of binding inhibitor(s) which affect both UF and ED measurements. (author)

  14. The impact of a low glycaemic index (GI) diet on simultaneous measurements of blood glucose and fat oxidation: A whole body calorimetric study.

    Science.gov (United States)

    Kaur, Bhupinder; Quek Yu Chin, Rina; Camps, Stefan; Henry, Christiani Jeyakumar

    2016-06-01

    Low glycaemic index (GI) foods are known to minimize large fluctuations in blood glucose levels and have been suggested to increase fat oxidation. The objective of this study was to simultaneously investigate glucose excursion and substrate oxidation in a whole body calorimetre when Chinese male subjects were provided a low or high GI meal. In a randomized, controlled crossover non blind design, 12 healthy Chinese male adults (BMI 21.8 ± 1.3 kgm -2 ) attended two sessions consisting of either four low or high glycaemic meals (LGI vs HGI). Breakfast, lunch and snack were consumed in a whole body calorimetre while dinner was consumed at home. Daily changes in glycaemic response (GR) and postprandial GR responses were measured using a continuous glucose monitoring system. The GR was further calculated to obtain the incremental area under the curve (iAUC) for glucose concentrations. Glycaemic variability was calculated as mean amplitude of glycaemic excursion (MAGE). Substrate oxidation was calculated by measuring respiratory quotient and urine nitrogen excretion. After LGI meals in the whole body calorimetre, iAUC for glucose (P = 0.008) was lower compared to the HGI session. The HGI treatment produced a significantly greater MAGE than the LGI treatment over the 24 hour period (P fat oxidation and lower carbohydrate oxidation were observed following breakfast and lunch when comparing LGI to HGI (P fat oxidation over carbohydrate oxidation when compared to HGI mixed meals. The consumption of low GI meals may be a strategic approach in improving overall glycaemia and increasing fat oxidation in Asians consuming a high carbohydrate diet.

  15. Measurement of regional cerebral metabolic rate for glucose in the human subject with (F-18)-2-deoxy-2-fluoro-d-glucose and emission computed tomography: validation of the method

    International Nuclear Information System (INIS)

    Phelps, M.E.; Huang, S.C.; Hoffman, E.J.; Selin, C.; Kuhl, D.E.

    1977-01-01

    Tracer techniques and models of in vitro quantitative autoradiography and tissue counting for the measure of regional metabolic rates (rMR) are combined with emission computed tomography (ECT). This approach, Physiologic Tomography (PT), provides atraumatic and analytical measurements of rMR. PT is exemplified with the regional measurement of the cerebral metabolic rate for glucose (CMRGlu) in man with ( 18 F)-2-deoxy-2-fluoro-D-glucose (FDG) and positron ECT. Our model incorporates a k 4 * mediated hydrolysis of FDG-6-PO 4 to FDG which then competes with phosphorylation (k 3 *) of FDG back to FDG-6-PO 4 and reverse transport (k 2 *) back to blood. Although small, k 4 * is found to be significant. The ECAT positron tomograph was used to measure the rate constants (k 1 *→k 4 *), lumped constant (LC), stability, and reproducibility of the model in man. Since these parameters have not been measured for FDG in any species, comparisons are made to values for DG in rat and monkey. Compartmental concentrations of FDG and FDG-6-PO 4 were determined and show that cerebral FDG-6-PO 4 steadily accumulates for about 100 mins, plateaus and then slowly decreases due to hydrolysis. Cerebral blood FDG concentration was determined to be a minor contribution to tissue activity after 10 min. Regional CMRGlu measurements are reproducible to +- 5.5% over 5 hrs. PT allows the in vivo study ofregional biochemistry and physiology in normal and pathophysiologic states in man with a unique and fundamental capability

  16. Selective conversion of plasma glucose into CO2 by Saccharomyces cerevisiae for the measurement of C-13 abundance by isotope ratio mass spectrometry : proof of principle

    NARCIS (Netherlands)

    Rembacz, Krzysztof P.; Faber, Klaas Nico; Stellaard, Frans

    2007-01-01

    To study carbohydrate digestion and glucose absorption, time-dependent C-13 enrichment in plasma glucose is measured after oral administration of naturally occurring C-13-enriched carbohydrates. The isotope enrichment of the administered carbohydrate is low (APE <0.1%) and plasma C-13 glucose

  17. assessment of Seawater Intrusion in Concrete by Measuring Chlorine Concentration

    International Nuclear Information System (INIS)

    Abdel-Monem, A.M.; Kansouh, W.A.; Osman, A.M.; Bashter, I.I.

    2011-01-01

    The object of this work is to measure water intrusion in concrete using a new methodology based on neutron activation technique. The applied method depends on measuring the activated gamma energy lines emitted from 38 Cl using a gamma spectrometer with Ge(Li) and HPGe detectors. Concrete samples with different percentages of silica fume (SF), up to 20 % submerged in seawater for different period of time were used to perform the investigation. Samples of concrete taken from different positions along the direction of water intrusion in concrete block were irradiated by thermal neutrons using the irradiation cell of 252 Cf neutron source and one of the vertical channels of search reactor at Delft University. The measured 38 Cl concentrations of the irradiated samples were used to plot groups of water profiles distribution in concrete samples with different SF % and submerged in seawater for different periods. These profiles were compared with the others which use here measured by neutron back emitted method where a satisfactory agreement was observed between the two. Further, the displayed measured results; show that the diffusivity for all water contents decreases with increasing the silica fume percentage up to 15 %. However, for concrete samples with silica fume 20 % the observed phenomenon is reversed due to the deterioration of concrete physical and mechanical properties

  18. Are serum adiponectin concentrations in a population sample of 64-year-old Caucasian women with varying glucose tolerance associated with ultrasound-assessed atherosclerosis?

    Science.gov (United States)

    Behre, C J; Brohall, G; Hulthe, J; Wikstrand, J; Fagerberg, B

    2006-09-01

    To examine whether serum adiponectin concentrations were associated with subclinical atherosclerosis assessed as intima media thickness (IMT) in the carotid arteries in Caucasian women with varying degrees of glucose tolerance. From a population-based cohort of 64-year-old Swedish women, 533 subjects with type 2 diabetes (DM2, n=177), impaired glucose tolerance (IGT; n=178) or normal glucose tolerance (NGT, n=178) were recruited. Anthropometrics, usual cardiovascular risk factors were examined and ultrasound examination of the carotid arteries was performed. Women with low adiponectin concentrations were characterized by thick IMT, higher prevalence of DM2, history of previous myocardial infarction, angina pectoris, anti-hypertensive treatment and high body mass index (BMI), waist circumference, plasma insulin, serum triglycerides, fasting glucose, HbA1c, and low serum HDL cholesterol levels. Carotid IMT correlated with HbA1c (r=0.24, PDM2 (r=0.16, P<0.001), systolic blood pressure (r=0.16, P<0.001), blood glucose (r=0.16, P<0.001), triglycerides (r=0.15, P<0.001), and reversely to adiponectin (r=-0.11, P=0.01), HDL cholesterol (r=-0.13, P=0.004), and alcohol intake (r=-0.087, P<0.05). A more detailed analysis of underlying associations was difficult due to a high co-linearity between these variable. Low serum adiponectin concentrations were associated with increased carotid artery IMT, and several risk factors for cardiovascular diseases, mainly those constituting the metabolic syndrome.

  19. Si-Traceable Scale for Measurements of Radiocarbon Concentration

    Science.gov (United States)

    Hodges, Joseph T.; Fleisher, Adam J.; Liu, Qingnan; Long, David A.

    2017-06-01

    Radiocarbon (^{14}C) dating of organic materials is based on measuring the ^{14}C/^{12}C atomic fraction relative to the nascent value that existed when the material was formed by photosynthetic conversion of carbon dioxide present in the atmosphere. This field of measurement has numerous applications including source apportionment of anthropogenic and biogenic fuels and combustion emissions, carbon cycle dynamics, archaeology, and forensics. Accelerator mass spectrometry (AMS) is the most widely used method for radiocarbon detection because it can measure extremely small amounts of radiocarbon (background of nominally 1.2 parts-per-trillion) with high relative precision (0.4 %). AMS measurements of radiocarbon are typically calibrated by reference to standard oxalic-acid (C_2H_2O_4) samples of known radiocativity that are derived from plant matter. Specifically, the internationally accepted absolute dating reference for so-called "modern-equivalent" radiocarbon is 95 % of the specific radioactivity in AD 1950 of the National Bureau of Standards (NBS) oxalic acid standard reference material and normalized to δ^{13}C_{VPDB} = 19 per mil. With this definition, a "modern-equivalent" corresponds to 1.176(70) parts-per-trillion of ^{14}C relative to total carbon content. As an alternative radiocarbon scale, we propose an SI-traceable method to determine ^{14}C absolute concentration which is based on linear Beer-Lambert-law absorption measurements of selected ^{14}C^{16}O_2 ν_3-band line areas. This approach is attractive because line intensities of chosen radiocarbon dioxide transitions can be determined by ab initio calculations with relative uncertainties below 0.5 %. This assumption is justified by the excellent agreement between theoretical values of line intensities and measurements for stable isotopologues of CO_2. In the case of cavity ring-down spectroscopy (CRDS) measurements of ^{14}C^{16}O_2 peak areas, we show that absolute, SI-traceable concentrations of

  20. Kinetic Behaviour of Glucose 6-Phosphate Dehydrogenase and 6-Phosphogluconate Dehydrogenase in Different Tissues of Rainbow Trout (Oncorhynchus mykiss Exposed to Non-Lethal Concentrations of Cadmium

    Directory of Open Access Journals (Sweden)

    Olcay Hisar

    2009-01-01

    Full Text Available The effects of cadmium (Cd on the enzymatic activities of glucose 6-phosphate dehydrogenase (G6PD and 6-phosphogluconate dehydrogenase (6PGD were investigated in the gill, liver and kidney tissues of rainbow trout (Oncorhynchus mykiss. Three test groups of fish were subjected to increasing concentrations (1, 3 and 5 mg/l of cadmium (Cd in vivo, respectively. The G6PD and 6PGD activities in the gill, liver, and kidney tissues of each group of fish were measured on days 1, 3, 5 and 7. G6PD and 6PGD enzyme activities, measured in gill, liver and kidney homogenates, were stimulated by various concentrations (1, 3, and 5 mg/l of cadmium. Although the dose-response pattern of G6PD enzyme activities in liver and kidney tissue was very similar, that in gill was different from both other tissues. The enzyme activity of G6PD enzyme was significantly stimulated after three days (Day 3 in liver and kidney tissues at a dose of 1 mg/l Cd (p p p p p p < 0.05 in liver and kidney tissues at the doses of 3 and 1 mg/l Cd. The stimulation effect of cadmium on the three tissues studied was also calculated; for both of the enzymes (G6PD and 6PGD, the enzyme activity levels were stimulated by approximately 60% and 38% in gills, 68% and 44% in liver, and 67% and 41% in kidneys, respectively, over the base-line enzyme activity of the control groups during the sevenday experimental period. These findings indicate that tissue G6PD and 6PGD enzymes function to protect against cadmium toxicity.

  1. Measurements of thoron and radon progeny concentrations in Beijing, China

    International Nuclear Information System (INIS)

    Zhang Lei; Liu Cuihong; Guo Qiuju

    2008-01-01

    It has been reported that thoron levels in China are above the world average and may therefore make a significant contribution to the natural background radiation dose. We therefore conducted a pilot study of concentrations of both thoron and radon progeny during the spring of 2006 in the Beijing area, China. A new type of portable 24 h integrating monitor with a CR-39 detector was used during the survey. Seventy dwellings and eight outdoor sites were measured during the survey. For country houses built of red bricks and slurry, the average equilibrium equivalent concentrations (EEC) of thoron and radon were 1.02 ± 0.48 and 16.41 ± 9.02 Bq m -3 , respectively, whereas for city dwellings built of cement blocks and floor slabs, the results were 0.48 ± 0.47 and 11.50 ± 6.99 Bq m -3 for thoron and radon, respectively. For outdoor air, concentrations of thoron and radon progeny were 0.29 ± 0.28 and 7.05 ± 2.68 Bq m -3 , respectively. Radiation exposures from thoron and radon progeny were also evaluated; the ratio of dose contribution from thoron progeny to that of radon progeny was evaluated to be 28% and 17% in country houses and city dwellings, respectively. (note)

  2. Measurements of indoor 222Rn concentration in two art galleries

    International Nuclear Information System (INIS)

    Carneiro, Luana Gomes; Braz, Delson; Jesus, Edgar Francisco de; Cunha, Kenya Dias da; Medeiros, Geiza; Zouain, Felipe; Pitassi, Gabriel; Leite, Carlos Barros; Cardoso, Katia

    2009-01-01

    It is point out that radon and their decay products in environment give high dose to human lung. Studies indicate that the indoor radon inhalation by humans has been considered probably the second most important cause of lung cancer after of smoking. A passive-type radon detector was used for measuring indoor radon concentration in two art galleries at Rio de Janeiro city during 90 days January to March, 2009. The aim of this study is to evaluate the occupational and public radon exposure in art galleries and museums. This paper shows the preliminary results of samples collected at two art galleries located in Gavea, Rio de Janeiro city. 30 LEXAN (GE) track detectors were exposed in the air (indoor as well as outdoor). The samples were collected in the same building which is a construction of XIX century. The analysis of the results suggests that the 222 Rn concentration levels are different in both sampling site, in closed environmental, demonstrating that, although the construction materials are the same the absence of circulating air is a factor very important to increase the concentration of indoor Rn. (author)

  3. Incorporation monitoring by measurements of activity concentrations in air

    International Nuclear Information System (INIS)

    Breukelmann, G.; Dalheimer, A.; Dilger, H.; Henrichs, K.

    1997-01-01

    The incorporation monitoring of workers handling actinides is in many cases not possible by individual methods: The sensitivity of bioassay of methods (in vivo, in vitro) is not sufficient to detect amounts as required by the low annual limits of intake. Similar difficulties may occur with the use of radionuclides with very short physical half-lives. In these cases, the measuring of activity concentrations in the air is the only way to monitor the workers and to meet legal requirements. The essential problem connected with this approach is to make sure, that the air sample analyzed represents the average air inhaled actually. Correspondingly, the new system regulating the incorporation monitoring in Germany requires additional measures to ensure this representatively. (author)

  4. Reliability of point-of-care hematocrit, blood gas, electrolyte, lactate and glucose measurement during cardiopulmonary bypass.

    NARCIS (Netherlands)

    Steinfelder-Visscher, J.; Weerwind, P.W.; Teerenstra, S.; Brouwer, René

    2006-01-01

    BACKGROUND: Recently, the GEM Premier blood gas analyser was upgraded to the GEM Premier 3000. In addition to pH, pCO2, pO2, Na+, K+, Ca2+, and hematocrit measurement, glucose and lactate can be measured on the GEM Premier 3000. In this prospective clinical study, the analytical performance of the

  5. Relation of measured brain glucose utilisation and cerebral atrophy in man.

    Science.gov (United States)

    Schlageter, N L; Horwitz, B; Creasey, H; Carson, R; Duara, R; Berg, G W; Rapoport, S I

    1987-06-01

    The effect of cerebral atrophy on measured cerebral metabolic rates for glucose (CMRglc), as determined with positron emission tomography (PET), was examined in 49 healthy males aged 21-83 years. Global CMRglc and regional CMRglc for 34 grey matter regions parallel to and from 30 to 80 mm above the inferior orbital meatal (IOM) line were measured under resting conditions, using [18F]-fluorodeoxyglucose and an ECAT II positron emission tomograph. Using a GE 8800 CT/T scanner, slices parallel to and from 30 to 80 mm above the IOM line were analysed for CSF volume. Cerebral atrophy, indicated by increased CSF volume, was correlated significantly with global CMRglc, but accounted for no more than 13% of the variance in the CMRglc measurements. Methods for correcting for inter-subject variation in CSF volume were proposed. Global values for CMRglc, uncorrected or corrected for CSF volume, were found to be age invariant. These findings indicate that (a) cerebral atrophy has a small, but statistically significant effect on CMRglc as measured with PET; (b) CMRglc is age invariant in healthy males.

  6. Measurement limits to 134Cs concentration in soil

    International Nuclear Information System (INIS)

    Ahn, J.K.; Kim, J.S.; Lee, H.M.; Kim, H.; Kim, T.H.; Park, J.N.; Kang, Y.S.; Lee, H.S.; Kim, S.J.; Park, J.Y.; Ryu, S.Y.; Kim, H.-Ch.; Kang, W.G.; Kim, S.K.

    2011-01-01

    We investigate the caesium concentrations in soils in mountain areas near Gori nuclear power plant in Korea, focusing on the measurement limits to the 134 Cs. In order to lower the minimum detectable amount (MDA) of activity for the 134 Cs, we have used the ammonium molybdophosphate (AMP) precipitation method to get rid of the 40 K existing in natural radioactivity, which reduces the MDA activity about 10 times smaller than those without the AMP precipitation method. The MDA results for the 134 Cs were found to be in the range between 0.015 and 0.044 Bq/kg-dry weight. In order to diminish the background, we also have measured a part of the soil samples in Yangyang, a small town in the east coast of Korea. However, it turns out that in order to detect the 134 Cs in the samples the MDA should be reduced to the level of mBq/kg-dry weight. - Highlights: → We study the caesium concentrations in soils in mountain areas near Gori NPT in Korea. → We use the AMP precipitation method to lower the minimum detectable amount (MDA) of activity for the 134 Cs. → The results of the MDA for the 134 Cs turn out to be in the range between 0.015 and 0.044. → In order to detect the 134 Cs in the samples, the MDA should be reduced to the level of mBq/kg-dry weight.

  7. Measuring the energy security implications of fossil fuel resource concentration

    International Nuclear Information System (INIS)

    Lefevre, Nicolas

    2010-01-01

    Economic assessments of the welfare effects of energy insecurity are typically uncertain and fail to provide clear guidance to policy makers. As a result, governments have had little analytical support to complement expert judgment in the assessment of energy security. This is likely to be inadequate when considering multiple policy goals, and in particular the intersections between energy security and climate change mitigation policies. This paper presents an alternative approach which focuses on gauging the causes of energy insecurity as a way to assist policy making. The paper focuses on the energy security implications of fossil fuel resource concentration and distinguishes between the price and physical availability components of energy insecurity. It defines two separate indexes: the energy security price index (ESPI), based on the measure of market concentration in competitive fossil fuel markets, and the energy security physical availability index (ESPAI), based on the measure of supply flexibility in regulated markets. The paper illustrates the application of ESPI and ESPAI with two case studies-France and the United Kingdom-looking at the evolution of both indexes to 2030.

  8. Measuring the energy security implications of fossil fuel resource concentration

    Energy Technology Data Exchange (ETDEWEB)

    Lefevre, Nicolas [Woodrow Wilson School of Public and International Affairs, Princeton University, New Jersey (United States)

    2010-04-15

    Economic assessments of the welfare effects of energy insecurity are typically uncertain and fail to provide clear guidance to policy makers. As a result, governments have had little analytical support to complement expert judgment in the assessment of energy security. This is likely to be inadequate when considering multiple policy goals, and in particular the intersections between energy security and climate change mitigation policies. This paper presents an alternative approach which focuses on gauging the causes of energy insecurity as a way to assist policy making. The paper focuses on the energy security implications of fossil fuel resource concentration and distinguishes between the price and physical availability components of energy insecurity. It defines two separate indexes: the energy security price index (ESPI), based on the measure of market concentration in competitive fossil fuel markets, and the energy security physical availability index (ESPAI), based on the measure of supply flexibility in regulated markets. The paper illustrates the application of ESPI and ESPAI with two case studies - France and the United Kingdom - looking at the evolution of both indexes to 2030. (author)

  9. Radioactivity concentration measuring device for radiation waste containing vessel

    International Nuclear Information System (INIS)

    Goto, Tetsuo.

    1994-01-01

    The device of the present invention can precisely and accurately measure a radioactive concentration of radioactive wastes irrespective of the radioactivity concentration distribution. Namely, a Ge detector having a collimator and a plurality of radiation detectors are placed at the outside of the radioactive waste containing vessel in such a way that it can rotate and move vertically relative to the vessel. The plurality of radiation detectors detect radiation coefficient signals at an assumed segment unit of a predetermined length in vertical direction and for every predetermined angle unit in the rotational direction. A weight measuring device determines the weight of the vessel. A computer calculates an average density of radioactivity for the region filled with radioactivity based on the determined net weight and radiation coefficient signals assuming that the volume of the radioactivity is constant. In addition, the computer calculates the amount of radioactivity in the assumed segment by conducting γ -ray absorption compensation calculation for the material in the vessel. Each of the amount of radioactivity is integrated to determine the amount of radioactivity in the vessel. (I.S.)

  10. Tracking and shape errors measurement of concentrating heliostats

    Science.gov (United States)

    Coquand, Mathieu; Caliot, Cyril; Hénault, François

    2017-09-01

    In solar tower power plants, factors such as tracking accuracy, facets misalignment and surface shape errors of concentrating heliostats are of prime importance on the efficiency of the system. At industrial scale, one critical issue is the time and effort required to adjust the different mirrors of the faceted heliostats, which could take several months using current techniques. Thus, methods enabling quick adjustment of a field with a huge number of heliostats are essential for the rise of solar tower technology. In this communication is described a new method for heliostat characterization that makes use of four cameras located near the solar receiver and simultaneously recording images of the sun reflected by the optical surfaces. From knowledge of a measured sun profile, data processing of the acquired images allows reconstructing the slope and shape errors of the heliostats, including tracking and canting errors. The mathematical basis of this shape reconstruction process is explained comprehensively. Numerical simulations demonstrate that the measurement accuracy of this "backward-gazing method" is compliant with the requirements of solar concentrating optics. Finally, we present our first experimental results obtained at the THEMIS experimental solar tower plant in Targasonne, France.

  11. Postprandial glucose response to selected tropical fruits in normal glucose-tolerant Nigerians.

    Science.gov (United States)

    Edo, A; Eregie, A; Adediran, O; Ohwovoriole, A; Ebengho, S

    2011-01-01

    The glycemic response to commonly eaten fruits in Nigeria has not been reported. Therefore, this study assessed the plasma glucose response to selected fruits in Nigeria. Ten normal glucose-tolerant subjects randomly consumed 50 g carbohydrate portions of three fruits: banana (Musa paradisiaca), pineapple (Ananus comosus), and pawpaw (Carica papaya), and a 50-g glucose load at 1-week intervals. Blood samples were collected in the fasting state and half-hourly over a 2-h period post-ingestion of the fruits or glucose. The samples were analyzed for plasma glucose concentrations. Plasma glucose responses were assessed by the peak plasma glucose concentration, maximum increase in plasma glucose, 2-h postprandial plasma glucose level, and incremental area under the glucose curve and glycemic index (GI). The results showed that the blood glucose response to these three fruits was similar in terms of their incremental areas under the glucose curve, maximum increase in plasma glucose, and glycemic indices (GIs). The 2-h postprandial plasma glucose level of banana was significantly higher than that of pineapple, P < 0.025. The mean ± SEM GI values were as follows: pawpaw; 86 ± 26.8%; banana, 75.1 ± 21.8%; pineapple, 64.5 ± 11.3%. The GI of glucose is taken as 100. The GI of pineapple was significantly lower than that of glucose (P < 0.05). Banana, pawpaw, and pineapple produced a similar postprandial glucose response. Measured portions of these fruits may be used as fruit exchanges with pineapple having the most favorable glycemic response.

  12. A Comparative Study of Blood Glucose Measurements Using Glucometer Readings and the Standard Method in the Diagnosis of Neonatal Hypoglycemia

    Directory of Open Access Journals (Sweden)

    Mohammad Torkaman

    2016-03-01

    Full Text Available Background: Hypoglycemia is one of the most common neonatal disorders, associated with severe complications. There has been a great deal of controversy regarding the definition and screening of hypoglycemia. Therefore, in this study, we aimed to determine a cut-off value for blood glucose level in glucometer readings. Methods: This cross-sectional study was conducted on 238 newborns at risk of hypoglycemia, admitted to Baqiyatallah Hospital of Tehran, Iran in 2012; the subjects were selected via simple sampling. After obtaining informed consents from the newborns’ parents, 1 cc blood samples were sent to the laboratory for measuring the blood glucose level. Moreover, venous blood samples, as well as heel-stick blood samples, were obtained for glucometer measurements. Blood glucose measurements were used to determine the cut-off value by the receiver operating characteristic (ROC curve and make comparisons with the diagnostic criteria for hypoglycemia in the literature. Results: A total of 238 infants with the mean weight of 2869±821.9 g were enrolled in this study. The mean (±SD blood glucose levels were 65.1±22.9, 82.9±24.7, and 84.4±24.8 mg/dl, based on the standard laboratory method, glucometer reading of venous blood samples, and glucometer reading of heel-stick capillary blood samples, respectively. The optimal cut-off point for hypoglycemia was determined as 65 mg/dl, using glucometer-based assessment of heel-stick blood samples. Conclusion: The significant difference in blood glucose levels measured by the laboratory method and outpatient glucometer readings highlights the importance of a cut-off value for rapid assessment and control of blood glucose and timely detection of hypoglycemia. In fact, the cut-off value introduced in the present study could facilitate such measurements.

  13. Estimation of liver glucose metabolism after refeeding

    International Nuclear Information System (INIS)

    Rognstad, R.

    1987-01-01

    Refeeding or infusing glucose to rats fasted for 24 hr or more causes rapid liver glycogen synthesis, the carbon source now considered to be largely from gluconeogenesis. While substrate cycling between plasma glucose and liver glucose-6P is known to occur, this cycling has apparently been ignored when calculations are made of % contribution of direct and indirect pathways to liver glycogen synthesis, or when hepatic glucose output is calculated from glucose turnover minus the glucose infusion rate. They show that, isotopically, an estimate of the fluxes of liver glucokinase and glucose-6-phosphatase is required to quantitate sources of carbon for liver glycogen synthesis, and to measure hepatic glucose output (or uptake). They propose a method to estimate these fluxes, involving a short infusion of a 14 C labelled gluconeogenic precursor plus (6T)glucose, with determination of isotopic yields in liver glycogen and total glucose. Given also the rate of liver glycogen synthesis, this procedure permits the estimation of net gluconeogenesis and hepatic glucose output or uptake. Also, in vitro evidence against the notion of a drastic zonation of liver carbohydrate metabolism is presented, e.g. raising the glucose concentration from 10 to 25 mM increases the 14 C yield from H 14 CO 3 - in lactate, with the increased pyruvate kinase flux and decreased gluconeogenesis occurring in the same cell type, not opposing pathways in different hepatocyte types (as has been postulated by some to occur in vivo after refeeding

  14. Translating HbA1c measurements into estimated average glucose values in pregnant women with diabetes.

    Science.gov (United States)

    Law, Graham R; Gilthorpe, Mark S; Secher, Anna L; Temple, Rosemary; Bilous, Rudolf; Mathiesen, Elisabeth R; Murphy, Helen R; Scott, Eleanor M

    2017-04-01

    This study aimed to examine the relationship between average glucose levels, assessed by continuous glucose monitoring (CGM), and HbA 1c levels in pregnant women with diabetes to determine whether calculations of standard estimated average glucose (eAG) levels from HbA 1c measurements are applicable to pregnant women with diabetes. CGM data from 117 pregnant women (89 women with type 1 diabetes; 28 women with type 2 diabetes) were analysed. Average glucose levels were calculated from 5-7 day CGM profiles (mean 1275 glucose values per profile) and paired with a corresponding (±1 week) HbA 1c measure. In total, 688 average glucose-HbA 1c pairs were obtained across pregnancy (mean six pairs per participant). Average glucose level was used as the dependent variable in a regression model. Covariates were gestational week, study centre and HbA 1c . There was a strong association between HbA 1c and average glucose values in pregnancy (coefficient 0.67 [95% CI 0.57, 0.78]), i.e. a 1% (11 mmol/mol) difference in HbA 1c corresponded to a 0.67 mmol/l difference in average glucose. The random effects model that included gestational week as a curvilinear (quadratic) covariate fitted best, allowing calculation of a pregnancy-specific eAG (PeAG). This showed that an HbA 1c of 8.0% (64 mmol/mol) gave a PeAG of 7.4-7.7 mmol/l (depending on gestational week), compared with a standard eAG of 10.2 mmol/l. The PeAG associated with maintaining an HbA 1c level of 6.0% (42 mmol/mol) during pregnancy was between 6.4 and 6.7 mmol/l, depending on gestational week. The HbA 1c -average glucose relationship is altered by pregnancy. Routinely generated standard eAG values do not account for this difference between pregnant and non-pregnant individuals and, thus, should not be used during pregnancy. Instead, the PeAG values deduced in the current study are recommended for antenatal clinical care.

  15. Insulin hypersecretion together with high luteinizing hormone concentration augments androgen secretion in oral glucose tolerance test in women with polycystic ovarian disease.

    Science.gov (United States)

    Anttila, L; Koskinen, P; Jaatinen, T A; Erkkola, R; Irjala, K; Ruutiainen, K

    1993-08-01

    Female hyperandrogenism is often associated with hyperinsulinaemia and insulin resistance. We evaluated the hormone responses in an oral glucose tolerance test to investigate the interactions of gonadotrophins, insulin, C-peptide and androgens in women with polycystic ovarian disease (PCOD). In 28 patients with ultrasonographically diagnosed PCOD, hyperinsulinaemia and insulin resistance were mainly associated with obesity. Both basal and cumulative sum of insulin to C-peptide ratios were high in obese subjects, suggesting decreasing hepatic removal of insulin caused by obesity. Nevertheless, in some lean PCOD women, despite normal fasting insulin concentrations, insulin hypersecretion existed. The mean concentration of testosterone decreased significantly during the oral glucose tolerance test both in PCOD and control women, and of androstenedione in the PCOD patients only. However, an increase in androgen responses was found in a subgroup of PCOD patients, who had both elevated luteinizing hormone (LH) concentrations and hyperinsulinaemic response to oral glucose. In the remaining PCOD patients an inverse correlation between LH and insulin was found. The patients with hyperinsulinaemia together with LH hypersecretion may represent a subgroup of PCOD with deranged regulation of androgen secretion.

  16. Laboratory Measurements of Particulate Matter Concentrations from Asphalt Pavement Abrasion

    Directory of Open Access Journals (Sweden)

    Fullová Daša

    2016-12-01

    Full Text Available The issue of emissions from road traffic is compounded by the fact that the number of vehicles and driven kilometres increase each year. Road traffic is one of the main sources of particulate matter and traffic volume is still increasing and has unpleasant impact on longevity of the pavements and the environment. Vehicle motions cause mechanical wearing of the asphalt pavement surface - wearing course by vehicle tyres. The contribution deals with abrasion of bituminous wearing courses of pavements. The asphalt mixtures of wearing courses are compared in terms of mechanically separated particulate matter. The samples of asphalt mixtures were rutted in wheel tracking machine. The particulate matter measurements were performed in laboratory conditions. The experimental laboratory measurements make it possible to sample particulates without contamination from exhaust emissions, abraded particles from vehicles, resuspension of road dust and climate affects. The contribution offers partial results of measurements on six trial samples of asphalt mixtures with different composition. It presents particulate matter morphology and the comparison of rutted asphalt samples in terms of PM mass concentrations and chemical composition.

  17. Serial alterations in digital hemodynamics and endothelin-1 immunoreactivity, platelet-neutrophil aggregation, and concentrations of nitric oxide, insulin, and glucose in blood obtained from horses following carbohydrate overload.

    Science.gov (United States)

    Eades, Susan C; Stokes, Ashley M; Johnson, Philip J; LeBlanc, Casey J; Ganjam, Venkataseshu K; Buff, Preston R; Moore, Rustin M

    2007-01-01

    To quantify changes in endothelium-derived factors and relate those changes to various aspects of digital hemodynamics during the prodromal stages of carbohydrate overload (CHO)-induced laminitis in horses. 20 adult horses without abnormalities of the digit. Digital and jugular venous blood samples were collected at 1-hour intervals (for assessment of endothelin-1 [ET-1] immunoreactivity and measurement of glucose, insulin, and nitric oxide [NO] concentrations) or 4-hour intervals (CBC and platelet-neutrophil aggregate assessment) for 8 hours or 16 hours after induction of CHO-associated laminitis in horses treated with an ET-1 antagonist. Effects of treatment, collection site, and time and the random effects of horse on each variable were analyzed by use of a repeated-measures model. Where treatment and collection site had no significant effect, data were combined. Compared with baseline values, CHO resulted in changes in several variables, including a significant increase from baseline in digital blood ET-like immunoreactivity at 11 hours; digital blood ET-like immunoreactivity was significantly greater than that in jugular venous blood at 8, 9, 11, and 12 hours. Digital and jugular venous blood concentrations of glucose increased from baseline significantly at 3, 4, and 5 hours; insulin concentration increased significantly at 5 hours; and the number of platelet-neutrophil aggregates increased significantly at 12 hours. In horses, concurrent increases in venous blood ET-1 immunoreactivity, insulin and glucose concentrations, and platelet-neutrophil aggregates support a role of endothelial dysfunction in the pathogenesis of CHO-induced laminitis.

  18. A positron emission tomography analysis of glucose metabolism in Alzheimer's disease brain using [18F] fluorodeoxyglucose. A parallel study with elemental concentrations

    International Nuclear Information System (INIS)

    Cutts, D.A.; Spyrou, N.M.; Stedman, J.D.

    2000-01-01

    Alzheimer's disease (AD) is a debilitating form of dementia which leads to impaired memory, thinking and behavior. Elemental concentrations between 'normal' and AD subjects as well as the hemispherical differences within the brain were examined. Tissue samples from both hemispheres of the frontal lobe in both AD and normal subjects were examined for their trace element concentrations using PIXE and RBS analyses. Elemental concentrations were seen to differ between AD and normal brain tissue samples. While in the normal group concentrations were found to be significantly higher in the right hemisphere than in the left the converse was tru in AD. A change in elemental concentrations may indicate possible alterations in the function of the blood brain barrier. This was examined by determining regional cerebral metabolic rates of glucose (rCMRGlu) using the in vivo technique of positron emission tomography (PET). Again variations between both hemispheres and between AD and normal were found. (author)

  19. Glucose Pump Test can be Used to Measure Blood Flow Rate of ...

    African Journals Online (AJOL)

    2018-02-07

    Feb 7, 2018 ... Blood flow rates of AV fistula can be affected by osmotic and oncotic pressures of blood and arterial blood pressures. Sodium, glucose, hemoglobin, and albumin are significant effectors, created osmotic and oncotic pressures [Table 3]. Blood levels of hemoglobin. (Hb), albumin, sodium (Na), and glucose ...

  20. Measurement of PCB concentrations in waters using a biomonitoring programme

    International Nuclear Information System (INIS)

    Mast, P.G.

    1993-01-01

    The book describes a PCB biomonitoring programme which was developed for measuring instantaneous PCB concentrations and permits the compilation of PCB action cadastres for different types of waters and subsequent derivation of current trends. Six representative congeners were selected as a basis for the quantitative routine analysis. The fish species bream (abramis brama) and roach (rutilus rutilus) were used as indicators in the PCB biomonitoring programme on account of their distribution and ecological demands. The age and growth rate of each fish destined for analysis was determined so as to ensure that only healthy fish would be used. In both fish species the dorsal musulature with its low scatter of test results and consistent PCB pattern (internal quantification) proved a representative body region. (orig.) [de

  1. Measurement of interstitial cetirizine concentrations in human skin

    DEFF Research Database (Denmark)

    Petersen, Lars Jelstrup; Church, M K; Rihoux, J P

    1999-01-01

    BACKGROUND: The purpose of the present study was to measure the concentrations of cetirizine in the extracellular water compartment in intact human skin and assess simultaneously inhibition of histamine-induced wheal and flare reactions. METHODS: Skin cetirizine levels were collected...... by the microdialysis technique and analyzed by high-pressure liquid chromatography with mass spectrometry detection. Skin levels in 20 subjects were compared to plasma levels for 4 h after a single oral dose of 10 or 20 mg of cetirizine. Skin prick tests were performed with histamine 100 mg/ml. RESULTS: Plasma...... cetirizine levels increased within 30 min to reach peak values of 315+/-10 and 786+/-45 ng/ml 90-120 min after administration of 10 and 20 mg of cetirizine. This was followed by a slow decline. In the skin, dialysate cetirizine levels (non-protein-bound fraction only) peaked at 1.6+/-0.1 and 2.4+/-0.3 ng...

  2. An Alpha spectrometer for measuring radon daughter individual activity concentration

    International Nuclear Information System (INIS)

    Berico, M.; Formignani, M.; Mariotti, F.

    2001-01-01

    In the frame of the program of the Institute for Radiation Protection of ENEA, related to the evaluation of dose from radon and thoron progeny, an alpha spectrometer for the continuous air monitoring (CAM type) of radon and thoron has been realized. The constructive characteristics of the device are here presented together with energy and efficiency calibration. The device allows, by means of a screen type diffusion battery and a filter, to determinate the single radioactivity of each radionuclide of the progeny selecting them in relation to their diffusive behaviour (dichotomous particle size selection). The three-count filter method has been employed to measure the concentrations of 218 Po, 214 Pb and 214 Bi in air. Radon and thoron effective doses using a dosimetric, instead of an epidemiologic approach, will be then evaluated [it

  3. Altered Expression of Somatostatin Receptors in Pancreatic Islets from NOD Mice Cultured at Different Glucose Concentrations In Vitro and in Islets Transplanted to Diabetic NOD Mice In Vivo

    Directory of Open Access Journals (Sweden)

    Eva Ludvigsen

    2011-01-01

    Full Text Available Somatostatin acts via five receptors (sst1-5. We investigated if the changes in pancreatic islet sst expression in diabetic NOD mice compared to normoglycemic mice are a consequence of hyperglycemia or the ongoing immune reaction in the pancreas. Pancreatic islets were isolated from NOD mice precultured for 5 days and further cultured for 3 days at high or low glucose before examined. Islets were also isolated from NOD mice and transplanted to normal or diabetic mice in a number not sufficient to cure hyperglycemia. After three days, the transplants were removed and stained for sst1-5 and islet hormones. Overall, changes in sst islet cell expression were more common in islets cultured in high glucose concentration in vitro as compared to the islet transplantation in vivo to diabetic mice. The beta and PP cells exhibited more frequent changes in sst expression, while the alpha and delta cells were relatively unaffected by the high glucose condition. Our findings suggest that the glucose level may alter sst expressed in islets cells; however, immune mechanisms may counteract such changes in islet sst expression.

  4. Parsing glucose entry into the brain: novel findings obtained with enzyme-based glucose biosensors.

    Science.gov (United States)

    Kiyatkin, Eugene A; Wakabayashi, Ken T

    2015-01-21

    Extracellular levels of glucose in brain tissue reflect dynamic balance between its gradient-dependent entry from arterial blood and its use for cellular metabolism. In this work, we present several sets of previously published and unpublished data obtained by using enzyme-based glucose biosensors coupled with constant-potential high-speed amperometry in freely moving rats. First, we consider basic methodological issues related to the reliability of electrochemical measurements of extracellular glucose levels in rats under physiologically relevant conditions. Second, we present data on glucose responses induced in the nucleus accumbens (NAc) by salient environmental stimuli and discuss the relationships between local neuronal activation and rapid glucose entry into brain tissue. Third, by presenting data on changes in NAc glucose induced by intravenous and intragastric glucose delivery, we discuss other mechanisms of glucose entry into the extracellular domain following changes in glucose blood concentrations. Lastly, by showing the pattern of NAc glucose fluctuations during glucose-drinking behavior, we discuss the relationships between "active" and "passive" glucose entry to the brain, its connection to behavior-related metabolic activation, and the possible functional significance of these changes in behavioral regulation. These data provide solid experimental support for the "neuronal" hypothesis of neurovascular coupling, which postulates the critical role of neuronal activity in rapid regulation of vascular tone, local blood flow, and entry of glucose and oxygen to brain tissue to maintain active cellular metabolism.

  5. Conditions With High Intracellular Glucose Inhibit Sensing Through Glucose Sensor Snf3 in Saccharomyces cerevisiae

    DEFF Research Database (Denmark)

    Karhumaa, Kaisa; Wu, B.Q.; Kielland-Brandt, Morten

    2010-01-01

    as for amino acids. An alternating-access model of the function of transporter-like sensors has been previously suggested based on amino acid sensing, where intracellular ligand inhibits binding of extracellular ligand. Here we studied the effect of intracellular glucose on sensing of extracellular glucose...... through the transporter-like sensor Snf3 in yeast. Sensing through Snf3 was determined by measuring degradation of Mth1 protein. High intracellular glucose concentrations were achieved by using yeast strains lacking monohexose transporters which were grown on maltose. The apparent affinity...... of extracellular glucose to Snf3 was measured for cells grown in non-fermentative medium or on maltose. The apparent affinity for glucose was lowest when the intracellular glucose concentration was high. The results conform to an alternating-access model for transporter-like sensors. J. Cell. Biochem. 110: 920...

  6. Evaluation of different disinfectants on the performance of an on-meter dosed amperometric glucose-oxidase-based glucose meter.

    Science.gov (United States)

    Sarmaga, Don; Dubois, Jeffrey A; Lyon, Martha E

    2011-11-01

    Off-meter dosed photometric glucose-oxidase-based glucose meters have been reported to be susceptible to interference by hydrogen-peroxide-based disinfecting agents. The objective of this study was to determine if a single application of hydrogen-peroxide-containing Accel® wipe to disinfect an on-meter dosed amperometric glucose-oxidase-based glucose meter will influence its performance. The performance of five on-meter dosed amperometric glucose-oxidase-based glucose meters was determined before and after disinfecting the devices with a single application of either CaviWipes® (14.3% isopropanol and 0.23% diisobutyl-phenoxy-ethoxyethyl dimethyl benzyl ammonium chloride) or Accel (0.5% hydrogen peroxide) wipes. Replicate glucose measurements were conducted before disinfecting the devices, immediately after disinfecting, and then 1 and 2 min postdisinfecting, with measurements in triplicate. Analysis was sequentially completed for five different meters. Results were analyzed by a two-way analysis of variance (Analyze-it software). No clinical ( .05) in glucose concentration were detected when the on-meter dosed amperometric glucose-oxidase-based glucose meters were disinfected with either CaviWipes or Accel wipes and measured immediately or 1 or 2 min postdisinfecting. No clinically significant difference in glucose concentration was detected between meters (glucose oxidase amperometric-based glucose meters are not analytically susceptible to interference by a single application of hydrogen-peroxide-containing Accel disinfectant wipes. © 2011 Diabetes Technology Society.

  7. Glucose cycling is markedly enhanced in pancreatic islets of obese hyperglycemic mice

    International Nuclear Information System (INIS)

    Khan, A.; Chandramouli, V.; Ostenson, C.G.; Berggren, P.O.; Loew, H.L.; Landau, B.R.; Efendic, S.

    1990-01-01

    Pancreatic islets from fed 7-month old lean and obese hyperglycemic mice (ob/ob) were incubated with 3H2O and 5.5 mM or 16.7 mM glucose. Incorporation of 3H into the medium glucose was taken as the measure of glucose-6-P hydrolysis to glucose. Glucose utilization was measured from the yield of 3H2O from [5-3H]glucose. Only 3-4% of the glucose phosphorylated was dephosphorylated by the lean mouse islets irrespective of the glucose concentration. In contrast, the ob/ob mouse islets at 5.5 mM glucose dephosphorylated 18% of the glucose phosphorylated and 30% at 16.7 mM. Thus, the islets of hyperglycemic mice demonstrate increased glucose cycling as compared to the islets of normoglycemic lean mice

  8. Local and systemic response to intramammary lipopolysaccharide challenge during long-term manipulated plasma glucose and insulin concentrations in dairy cows.

    Science.gov (United States)

    Vernay, M C M B; Wellnitz, O; Kreipe, L; van Dorland, H A; Bruckmaier, R M

    2012-05-01

    The metabolic load during periods of high milk production in dairy cows causes a variety of changes of metabolite blood concentrations including dramatically decreased glucose levels. These changes supposedly impair the immune system. The goal of this study was, therefore, to evaluate adaptations of the cow's immune system in response to an intramammary lipopolysaccharide (LPS) stimulation during a 3-d modification of plasma glucose and insulin induced by different clamp infusions. Seventeen midlactating dairy cows received a hypoglycemic hyperinsulinemic clamp induced by insulin infusion (HypoG; n=5), a euglycemic hyperinsulinemic clamp induced by insulin and glucose infusion (EuG; n=6), or infusion of saline solution (NaCl; n=6) for 56 h. At 48 h of infusion, 2 udder quarters were challenged with 200 μg of Escherichia coli LPS. At 48 h of infusion (immediately before LPS challenge), tumor necrosis factor α, lactoferrin, and serum amyloid A (SAA) mRNA abundance was increased in HypoG and Il-1β mRNA abundance was decreased in EuG. After LPS challenge, plasma glucose concentration did not decrease, although plasma insulin increased simultaneously in all groups either due to enhanced endogenous release (NaCl) or due to increased insulin infusion rate (HypoG; EuG). Plasma cortisol, rectal temperatures, and milk somatic cell count of challenged quarters increased, whereas plasma nonesterified fatty acid concentrations were similarly decreased across treatments. In mammary biopsies, increased mRNA expression of tumor necrosis factor α, IL-1β, IL-8, and IL-10, and SAA were observed in LPS-treated quarters of all groups, with a more pronounced increase in IL-1β, IL-10, and SAA expression in EuG. Nuclear factor-κB mRNA expression was upregulated in NaCl and EuG but not in HypoG in response to LPS. Lactoferrin, toll-like receptor 4, and cyclooxygenase-2 mRNA expression was increased in LPS-treated quarters of EuG only, and 5-lipoxygenase mRNA expression was decreased

  9. Age and sex differences in cerebral glucose consumption measured by pet using [18-F] fluorodeoxyglucose (FDG)

    International Nuclear Information System (INIS)

    Duara, R.; Barker, W.; Chang, J.; Apicella, A.; Finn, R.; Gilson, A.

    1985-01-01

    Resting cerebral glucose metabolic rates (CMRglc) were measured in 23 subjects by PET using FDG. Subjects were divided into several groups (mean age +- S.D.) 5 young males (YM) (27 +- 6); 6 young females (YF)(33 +9); 5 elderly males (EM)(73 +- 5); 7 elderly females (EF)(69 +- 7). Additionally, from these groups 4 YM, 3YF, 5EM and 4EF were studied again within 6 weeks under identical conditions. CMRglc in the YF group again was significantly hider than YM (p 0.05). No obvious relationships of CMRglc to the phase of the menstrual cycle was found in this small group. There was a trend (p=0.06) toward a higher CMRglc in YF than EF. These results support the findings of higher CBF in YF versus YM. The differences between the results of Kuhl et al (J. Cereb. and a reduction of CMRglc with age was found in a mixed group of males and females (58and female), and where no age effect was found the males, are also resolved by these findings. The authors suggest that the apparent age effect, in females in this study, is principally a hormonal one

  10. Radiometric assays for glycerol, glucose, and glycogen

    International Nuclear Information System (INIS)

    Bradley, D.C.; Kaslow, H.R.

    1989-01-01

    We have developed radiometric assays for small quantities of glycerol, glucose and glycogen, based on a technique described by Thorner and Paulus for the measurement of glycerokinase activity. In the glycerol assay, glycerol is phosphorylated with [32P]ATP and glycerokinase, residual [32P]ATP is hydrolyzed by heating in acid, and free [32P]phosphate is removed by precipitation with ammonium molybdate and triethylamine. Standard dose-response curves were linear from 50 to 3000 pmol glycerol with less than 3% SD in triplicate measurements. Of the substances tested for interference, only dihydroxyacetone gave a slight false positive signal at high concentration. When used to measure glycerol concentrations in serum and in media from incubated adipose tissue, the radiometric glycerol assay correlated well with a commonly used spectrophotometric assay. The radiometric glucose assay is similar to the glycerol assay, except that glucokinase is used instead of glycerokinase. Dose response was linear from 5 to 3000 pmol glucose with less than 3% SD in triplicate measurements. Glucosamine and N-acetylglucosamine gave false positive signals when equimolar to glucose. When glucose concentrations in serum were measured, the radiometric glucose assay agreed well with hexokinase/glucose-6-phosphate dehydrogenase (H/GDH)-based and glucose oxidase/H2O2-based glucose assays. The radiometric method for glycogen measurement incorporates previously described isolation and digestion techniques, followed by the radiometric assay of free glucose. When used to measure glycogen in mouse epididymal fat pads, the radiometric glycogen assay correlated well with the H/GDH-based glycogen assay. All three radiometric assays offer several practical advantages over spectral assays

  11. Effects of glucose ingestion on autonomic and cardiovascular measures during rest and mental challenge

    NARCIS (Netherlands)

    Synowski, S.J.; Kop, W.J.; Warwick, Z.S.; Waldstein, S.R.

    2013-01-01

    Background High levels of dietary sugar consumption may result in dysregulated glucose metabolism and lead to elevated cardiovascular disease risk via autonomic nervous system and cardiovascular dysfunction. Altered cardiovascular function can be examined using perturbation tasks such as mental

  12. Measurement of regional cerebral glucose utilization in man by positron emission tomography

    International Nuclear Information System (INIS)

    Baron, J.C.

    1986-05-01

    The various methods available for the study of regional cerebral glucose consumption in man by positron emission tomography are described and their applications, limitations and principal physiopathological results are presented [fr

  13. Precision of glucose measurements in control sera by isotope dilution/mass spectrometry: proposed definitive method compared with a reference method

    International Nuclear Information System (INIS)

    Pelletier, O.; Arratoon, C.

    1987-01-01

    This improved isotope-dilution gas chromatographic/mass spectrometric (GC/MS) method, in which [ 13 C]glucose is the internal standard, meets the requirements of a Definitive Method. In a first study with five reconstituted lyophilized sera, a nested analysis of variance of GC/MS values indicated considerable among-vial variation. The CV for 32 measurements per serum ranged from 0.5 to 0.9%. However, concentration and uncertainty values (mmol/L per gram of serum) assigned to one serum by the NBS Definitive Method (7.56 +/- 0.28) were practically identical to those obtained with the proposed method (7.57 +/- 0.20). In the second study, we used twice more [ 13 C]glucose diluent to assay four serum pools and two lyophilized sera. The CV ranged from 0.26 to 0.5% for the serum pools and from 0.28 to 0.59% for the lyophilized sera. In comparison, results by the hexokinase/glucose-6-phosphate dehydrogenase reference method agreed within acceptable limits with those by the Definitive Method but tended to be slightly higher (up to 3%) for lyophilized serum samples or slightly lower (up to 2.5%) for serum pools

  14. Glucose metabolism in diabetic blood vessels

    International Nuclear Information System (INIS)

    Brown, B.J.; Crass, M.F. III

    1986-01-01

    Since glycolysis appears to be coupled to active ion transport in vascular smooth muscle, alterations in glucose metabolism may contribute to cellular dysfunction and angiopathy in diabetes. Uptake and utilization of glucose were studied in perfused blood vessels in which pulsatile flow and perfusion pressure were similar to those measured directly in vivo. Thoracic aortae isolated from 8-wk alloxan diabetic (D) and nondiabetic control rabbits were cannulated, tethered, and perfused with oxygenated buffer containing 7 or 25 mM glucose and tracer amounts of glucose-U -14 C. Norepinephrine (NE) (10 -6 M) and/or insulin (I) (150 μU/ml) and albumin (0.2%) were added. NE-induced tension development increased glucose uptake 39% and 14 CO 2 and lactate production 2.3-fold. With 7 mM glucose, marked decreases in glucose uptake (74%), 14 CO 2 (68%), lactate (30%), total tissue glycogen (75%), and tissue phospholipids (70%) were observed in D. Addition of I or elevation of exogenous glucose to 25 mM normalized glucose uptake, but had differential effects on the pattern of substrate utilization. Thus, in D, there was a marked depression of vascular glucose metabolism that was partially reversed by addition of low concentrations of insulin or D levels of glucose

  15. Description and measurement of concentration problems in depressed patients.

    Science.gov (United States)

    Watts, F N; Sharrock, R

    1985-05-01

    Depressed patients commonly complain of concentration problems, yet these have seldom been the focus of systematic investigation. A structured interview about concentration problems was administered to a group of relatively severely depressed patients. Problems in reading and watching television were the most common, and were highly correlated with each other. Direct report of the number of concentration lapses on a reading task was the most generally satisfactory task-performance correlate of complaints of reading/TV concentration problems. Evidence both from this task and from the interview suggests that depressive concentration problems may often be due to 'mind-wandering'. The correlations with concentration problems with the severity and endogeneity of depression and with state anxiety were generally similar.

  16. Glucose-induced insulin resistance of skeletal-muscle glucose transport and uptake

    DEFF Research Database (Denmark)

    Richter, Erik; Hansen, B F; Hansen, S A

    1988-01-01

    in the presence of glucose and insulin. The data indicate that exposure to a moderately increased glucose concentration (12 mM) leads to rapidly developing resistance of skeletal-muscle glucose transport and uptake to maximal insulin stimulation. The effect of glucose is enhanced by simultaneous insulin exposure......, whereas exposure for 5 h to insulin itself does not cause measurable resistance to maximal insulin stimulation.......The ability of glucose and insulin to modify insulin-stimulated glucose transport and uptake was investigated in perfused skeletal muscle. Here we report that perfusion of isolated rat hindlimbs for 5 h with 12 mM-glucose and 20,000 microunits of insulin/ml leads to marked, rapidly developing...

  17. Glucose meters: evaluation of the new formulation measuring strips from Roche (Accu-Chek) and Abbott (MediSense).

    Science.gov (United States)

    Dimeski, G; Jones, B W; Tilley, V; Greenslade, M N; Russell, A W

    2010-07-01

    Both Roche and Abbott have released new glucose meter strips. They supply the entire Australian hospital market. The present study compared the performance of the new strips utilizing various specimen types (capillary, venous lithium heparin whole blood, venous lithium heparin plasma and serum) and evaluated how well they comply with the International Standards Organization (ISO) 15197 criteria. The study included imprecision, patient comparison and interference studies. Participants with and without diabetes were recruited to evaluate the performance of various specimen types against the Beckman DxC800 glucose method. The strips were tested for different interferences: galactose, maltose, lactose, Icodextrin, Intragam, paracetamol, sodium, ascorbic acid, variable strip storage temperature, haematocrit, haemolysis and lipaemia. The imprecision of the two strips was approximately 5% or less, except for the Abbott strip at very low values (1.4 mmol/L), approximately 7%. In total, 78% and 84%, respectively, of the results from the finger prick capillary specimens with the Roche (Accu-Chek Performa meter) and Abbott (Optium Xceed meter) strips, not 95% or greater as recommended by the ISO guideline, were within the recommended limits compared with reference plasma estimation on laboratory analysers. Galactose, ascorbic acid, haematocrit and sodium on the Roche and ascorbic acid and haematocrit on the Abbott strip continue to interfere to a variable degree with the glucose measurement. Analytically small differences exist between the glucose meter strips. The most significant analytical difference with the strips was at low glucose levels when compared with laboratory analyses and this may be of clinical importance. The impact of some of the interferences is variable between the two strips. Individuals, health-care professionals and health-care institutions should consider these data when selecting glucose meters for the management of people with diabetes mellitus.

  18. Toward CMOS image sensor based glucose monitoring.

    Science.gov (United States)

    Devadhasan, Jasmine Pramila; Kim, Sanghyo

    2012-09-07

    Complementary metal oxide semiconductor (CMOS) image sensor is a powerful tool for biosensing applications. In this present study, CMOS image sensor has been exploited for detecting glucose levels by simple photon count variation with high sensitivity. Various concentrations of glucose (100 mg dL(-1) to 1000 mg dL(-1)) were added onto a simple poly-dimethylsiloxane (PDMS) chip and the oxidation of glucose was catalyzed with the aid of an enzymatic reaction. Oxidized glucose produces a brown color with the help of chromogen during enzymatic reaction and the color density varies with the glucose concentration. Photons pass through the PDMS chip with varying color density and hit the sensor surface. Photon count was recognized by CMOS image sensor depending on the color density with respect to the glucose concentration and it was converted into digital form. By correlating the obtained digital results with glucose concentration it is possible to measure a wide range of blood glucose levels with great linearity based on CMOS image sensor and therefore this technique will promote a convenient point-of-care diagnosis.

  19. Measurement of fructose-asparagine concentrations in human and animal foods.

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Jikang; Sabag-Daigle, Anice; Metz, Thomas O.; Kaiser, Brooke LD; Gopalan, Venkat; Behrman, Edward J.; Wysocki, Vicki H.; Ahmer, Brian

    2018-01-10

    The food-borne bacterial pathogen, Salmonella enterica, can utilize fructose-asparagine (F-Asn) as the sole carbon and nitrogen source. F-Asn is the product of an Amadori rearrangement following the non-enzymatic condensation of glucose and asparagine. Heating converts F-Asn via complex Maillard reactions to a variety of molecules which contribute to the color, taste, and aroma of heated foods. Among these is acrylamide, which is present in some foods, especially in fried potato products. The F-Asn utilization pathway in Salmonella, specifically FraB, is a potential drug target because inhibition of this enzyme would lead to intoxication of Salmonella in the presence of F-Asn. However, F-Asn would need to be packaged with the FraB inhibitor, or available in human foods. To determine if there are foods that have sufficient F-Asn, we measured F-Asn concentrations in a variety of human and animal foods. The 399 pmol/mg F-Asn found in mouse chow is sufficient to intoxicate a Salmonella fraB mutant in mouse models of salmonellosis, and several human foods were found to have this concentration or higher (fresh apricots, lettuce, asparagus, and in canned peaches). Much higher concentrations (11,000 to 35,000 pmol/mg dry weight) were found in heat-dried apricots, apples, and asparagus. This report clarifies the origins of F-Asn as a nutrient source for Salmonella, and identifies foods that could be used in concert with a FraB inhibitor as a therapeutic agent for Salmonella.

  20. Influence of glucose and urea on 125I transport across an anion exchange paper membrane

    International Nuclear Information System (INIS)

    Inoue, Hiroyoshi

    2001-01-01

    In order to study the influence of glucose and urea on the 125 I transport across an anion exchange paper membrane, the transmembrane potential, the fluxes, and the concentrations of 125 I, glucose and urea within the membrane were measured in the Na 125 I concentration-cell system containing glucose or urea. Glucose and urea increased the membrane/solution distribution of the iodide ion, but scarcely affected the diffusion process of iodide ion within the membrane

  1. Addressing glucose sensitivity measured by F-18 FDG PET in lung cancers for radiation treatment planning and monitoring

    International Nuclear Information System (INIS)

    Wong, Ching-yee Oliver; Thie, Joseph; Gaskill, Marianne; Kestin, Larry; Yan Di; Cheng, Vincent; Nagle, Conrad

    2006-01-01

    Purpose: To address glucose sensitivity in lung cancers before and after radiation treatment (Tx). Methods and Materials: Twelve patients were each studied with two pre-Tx positron emission tomography (PET) scans and 3 patients each with one post-Tx PET scan, with glucose concentration [Glc] and maximum standard uptake value (SUV) recorded. The pre-Tx glucose sensitivity, g from SUV 1 /SUV 2 = {[Glc] 1 /[Glc] 2 } g and Tx index, τ from SUV post-Tx /SUV pre-Tx = {[Glc] post-Tx /[Glc] pre-Tx } τ was calculated by linear regression. Pre-Tx SUVs were corrected to post-Tx Glc with g (SUV' pre-Tx ) for a pure Tx effect, R ln(SUV post-Tx /SUV' pre-Tx ). Results: There were no significant differences in SUV but [Glc] were different (96.4 ± 10.9 vs. 88.3 ± 10.5, p = 0.015) between two pre-Tx PET scans. Linear regression yielded g -0.79 and τ = -1.78 to -2.41 (p < 0.0005 in all). The %ΔSUV after Tx for 3 patients without vs. with g correction were different by -12%, 0%, and + 7%, suggesting varying effects from glucose. R values were also different and mean R (-0.81 ± 0.38) was significantly different from zero (p = 0.03), consistent with successful Tx as confirmed by clinico-radiologic follow-up. Conclusions: The extra dimension of glucose sensitivity, g besides SUV incorporated in the combined Tx-derived τ may be a useful global Tx evaluation index even with differing [Glc

  2. Aspirin-mediated acetylation of haemoglobin increases in presence of high glucose concentration and decreases protein glycation

    Directory of Open Access Journals (Sweden)

    Francesco Finamore

    2015-09-01

    Full Text Available Glycation represents the first stage in the development of diabetic complications. Aspirin was shown to prevent sugars reacting with proteins, but the exact mechanism of this interaction was not well defined. We performed a quantitative analysis to calculate the levels of acetylation and glycation of haemoglobin, among others red blood cell (RBC proteins, using a label free approach. After glucose incubation, increases in the acetylation levels were seen for several haemoglobin subunits, while a parallel decrease of their glycation levels was observed after aspirin incubation. These results suggest that, a mutual influence between these two modifications, occur at protein level.

  3. Measurement of local interfacial area concentration in boiling loop

    International Nuclear Information System (INIS)

    Kyoung, Ho Kang; Byong, Jo Yun; Goon, Cherl Park

    1995-01-01

    An accurate prediction of two-phase flow is essential to many energy systems, including nuclear reactors. To model the two-phase flow, detailed information on the internal flow structure is required. The void fraction and interfacial area concentration are important fundamental parameters characterizing the internal structure of two-phase flow. The interfacial area concentration is defined as the available interfacial area per unit volume of the two-phase mixture in calculations of the interfacial transport of mass, momentum, and energy. Although a number of studies have been made in this area, the interfacial area concentration in two-phase flow has not been sufficiently investigated either experimentally or analytically. Most existing models for interfacial area concentration are limited to area-averaged interfacial area concentration in a flow channel. And the studies on local interfacial area concentration are limited to the case of air-water two-phase flow. However, the internal flow structure of steam-water two-phase flow having various bubble sizes could be quite different from that of air-water two-phase flow, the reliability of which weak in practical applications. In this study, the local interfacial area concentration steam-water two-phase flow has been investigated experimentally in a circular boiling tube having a heating rod in the center, and for the low flow with liquid superficial velocity <1 m/s

  4. Effect of Acarbose, Sitagliptin and combination therapy on blood glucose, insulin, and incretin hormone concentrations in experimentally induced postprandial hyperglycemia of healthy cats.

    Science.gov (United States)

    Mori, Akihiro; Ueda, Kaori; Lee, Peter; Oda, Hitomi; Ishioka, Katsumi; Arai, Toshiro; Sako, Toshinori

    2016-06-01

    Acarbose (AC) and Sitagliptin (STGP) are oral hypoglycemic agents currently used either alone or in conjunction with human diabetic (Type 2) patients. AC has been used with diabetic cats, but not STGP thus far. Therefore, the objective of this study was to determine the potential use of AC or STGP alone and in combination for diabetic cats, by observing their effect on short-term post-prandial serum glucose, insulin, and incretin hormone (active glucagon-like peptide-1 (GLP-1) and total glucose dependent insulinotropic polypeptide (GIP)) concentrations in five healthy cats, following ingestion of a meal with maltose. All treatments tended (pglucose area under the curve (AUC), with an accompanying significant reduction (pAUC as compared to no treatment. Meanwhile, a significant increase (pAUC was observed with STGP (100% higher) and combined treatment (130% greater), as compared to either AC or no treatment. Lastly, a significant reduction (pAUC was observed with STGP (21% reduction) and combined treatment (7% reduction) as compared to control. Overall, AC, STGP, or combined treatment can significantly induce positive post-prandial changes to insulin and incretin hormone levels of healthy cats. Increasing active GLP-1 and reducing postprandial hyperglycemia appear to be the principal mechanisms of combined treatment. Considering the different, but complementary mechanisms of action by which AC and STGP induce lower glucose and insulin levels, combination therapy with both these agents offers great potential for treating diabetic cats in the future. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Effect of Intravenous Small-Volume Hypertonic Sodium Bicarbonate, Sodium Chloride, and Glucose Solutions in Decreasing Plasma Potassium Concentration in Hyperkalemic Neonatal Calves with Diarrhea.

    Science.gov (United States)

    Trefz, F M; Constable, P D; Lorenz, I

    2017-05-01

    Hyperkalemia is a frequently observed electrolyte imbalance in dehydrated neonatal diarrheic calves that can result in skeletal muscle weakness and life-threatening cardiac conduction abnormalities and arrhythmias. Intravenous administration of a small-volume hypertonic NaHCO 3 solution is clinically more effective in decreasing the plasma potassium concentration (cK) in hyperkalemic diarrheic calves than hypertonic NaCl or glucose solutions. Twenty-two neonatal diarrheic calves with cK >5.8 mmol/L. Prospective randomized clinical trial. Calves randomly received either 8.4% NaHCO 3 (6.4 mL/kg BW; n = 7), 7.5% NaCl (5 mL/kg BW; n = 8), or 46.2% glucose (5 mL/kg BW; n = 7) IV over 5 minutes and were subsequently allowed to suckle 2 L of an electrolyte solution. Infusions with NaHCO 3 and NaCl provided an identical sodium load of 6.4 mmol/kg BW. Hypertonic NaHCO 3 infusions produced an immediate and sustained decrease in plasma cK. Hypertonic glucose infusions resulted in marked hyperglycemia and hyperinsulinemia, but cK remained unchanged for 20 minutes. Between 30 and 120 minutes after initiation of treatment, the most marked decrements in cK from baseline occurred in group NaHCO 3 , which were significantly (P < .05) larger during this period of time than in calves in group NaCl, but not group glucose. After 120 minutes, the mean decrease in cK from baseline was -26 ± 10%, -9 ± 8%, and -22 ± 6% in groups NaHCO 3 , NaCl, and glucose, respectively. Small-volume hypertonic NaHCO 3 infusions appear to have clinical advantages for the rapid resuscitation of hyperkalemic diarrheic calves, compared to hypertonic NaCl or glucose solutions. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  6. Clinical chemistry measurements with commercially available test slides on a smartphone platform: Colorimetric determination of glucose and urea.

    Science.gov (United States)

    Wu, Yuanyuan; Boonloed, Anukul; Sleszynski, Neal; Koesdjojo, Myra; Armstrong, Chadd; Bracha, Shay; Remcho, Vincent T

    2015-08-25

    Rapidly increasing healthcare costs in economically advantaged countries are currently unsustainable, while in many developing nations, even 50-year-old technologies are too expensive to implement. New and unconventional technologies are being explored as solutions to this problem. In this study, we examined the use of a smartphone as the detection platform for 2 well-developed, relatively inexpensive, commercially available clinical chemistry assays as a model for rapid and inexpensive clinical diagnostic testing. An Apple iPhone 4 camera phone equipped with a color analysis application (ColorAssist) was combined with Vitros® glucose and urea colorimetric assays. Color images of assay slides at various concentrations of glucose or urea were collected with the iPhone 4 and quantitated in three different spectral ranges (red/green/blue or RGB) using the ColorAssist app. When the diffuse reflectance data was converted into absorbance, it was possible to quantitate glucose or blood urea nitrogen (BUN) over their clinically important concentration ranges (30-515mg/dl for glucose or 2-190mg/dl for BUN), with good linearity (R(2)=0.9994 or 0.9996, respectively [n=5]). Data collected using the iPhone 4 and canine serum samples were in agreement with results from the instrumental "gold standard" (Beckman Coulter AU480 Chemistry System) (R(2)=0.9966 and slope=1.0001 for glucose; R(2)=0.9958 and slope=0.9454 for BUN). Glucose determinations of serum samples made using this smartphone method were as accurate as or more accurate than a commercial colorimetric dry slide analyzer (Heska® Element DC Chemistry Analyzer, Loveland, CO) and 2 glucometers: ReliOn® Ultima (Abbott Diabetes Care Inc) and Presto® (AgaMatrix Inc.H). BUN determinations made using the smartphone approach were comparable in accuracy to the Heska instrument. This demonstration shows that smartphones have the potential to be used as simple, effective colorimetric detectors for quantitative diagnostic tests

  7. Brain metabolism in autism. Resting cerebral glucose utilization rates as measured with positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Rumsey, J.M.; Duara, R.; Grady, C.; Rapoport, J.L.; Margolin, R.A.; Rapoport, S.I.; Cutler, N.R.

    1985-05-01

    The cerebral metabolic rate for glucose was studied in ten men (mean age = 26 years) with well-documented histories of infantile autism and in 15 age-matched normal male controls using positron emission tomography and (F-18) 2-fluoro-2-deoxy-D-glucose. Positron emission tomography was completed during rest, with reduced visual and auditory stimulation. While the autistic group as a whole showed significantly elevated glucose utilization in widespread regions of the brain, there was considerable overlap between the two groups. No brain region showed a reduced metabolic rate in the autistic group. Significantly more autistic, as compared with control, subjects showed extreme relative metabolic rates (ratios of regional metabolic rates to whole brain rates and asymmetries) in one or more brain regions.

  8. Brain metabolism in autism. Resting cerebral glucose utilization rates as measured with positron emission tomography

    International Nuclear Information System (INIS)

    Rumsey, J.M.; Duara, R.; Grady, C.; Rapoport, J.L.; Margolin, R.A.; Rapoport, S.I.; Cutler, N.R.

    1985-01-01

    The cerebral metabolic rate for glucose was studied in ten men (mean age = 26 years) with well-documented histories of infantile autism and in 15 age-matched normal male controls using positron emission tomography and (F-18) 2-fluoro-2-deoxy-D-glucose. Positron emission tomography was completed during rest, with reduced visual and auditory stimulation. While the autistic group as a whole showed significantly elevated glucose utilization in widespread regions of the brain, there was considerable overlap between the two groups. No brain region showed a reduced metabolic rate in the autistic group. Significantly more autistic, as compared with control, subjects showed extreme relative metabolic rates (ratios of regional metabolic rates to whole brain rates and asymmetries) in one or more brain regions

  9. Measurements of Radon Concentration in Yemen Using Spark Counter

    International Nuclear Information System (INIS)

    Arafa, W.; Abou-Leila, M.; Hafiz, M.E.; Al-Glal, N.

    2011-01-01

    Spark counter has been designed and realized and the optimum applied voltage was found to be 600 V. Excellent consistent agreements was observed between counted number of tracks by spark counter and reading by optical microscope. Radon concentration in some houses in Sana'a and Hodeidah cities in Yemen had been performed using LR-115 SSNTD and spark counter system. The average radon concentration in both cities was far lower the alert value. The results showed that radon concentration in the metropolitan area Sana'a was higher than that in Hodeidah city. Also, it was observed that old residential houses had higher levels of radon concentrations have compared to newly built houses in the metropolitan area Sana'a

  10. Comparison of optical coherence tomography, the pulsed photoacoustic technique, and the time-of-flight technique in glucose measurements in vitro

    OpenAIRE

    Kinnunen, M. (Matti)

    2006-01-01

    Abstract The development of a non-invasive glucose monitoring technique is very important because it would tremendously diminish the need to puncture the skin when taking blood samples and help diabetic patients in controlling their blood glucose levels and in treating Diabetes Mellitus. The focus of this thesis is on measuring the effect of glucose on the light scattering properties of a tissue-simulating phantom and biological tissues in vitro. Optical coherence tomography (OCT), the pul...

  11. Comparison of spectroscopically measured tissue alcohol concentration to blood and breath alcohol measurements

    Science.gov (United States)

    Ridder, Trent D.; Ver Steeg, Benjamin J.; Laaksonen, Bentley D.

    2009-09-01

    Alcohol testing is an expanding area of interest due to the impacts of alcohol abuse that extend well beyond drunk driving. However, existing approaches such as blood and urine assays are hampered in some testing environments by biohazard risks. A noninvasive, in vivo spectroscopic technique offers a promising alternative, as no body fluids are required. The purpose of this work is to report the results of a 36-subject clinical study designed to characterize tissue alcohol measured using near-infrared spectroscopy relative to venous blood, capillary blood, and breath alcohol. Comparison of blood and breath alcohol concentrations demonstrated significant differences in alcohol concentration [root mean square of 9.0 to 13.5 mg/dL] that were attributable to both assay accuracy and precision as well as alcohol pharmacokinetics. A first-order kinetic model was used to estimate the contribution of alcohol pharmacokinetics to the differences in concentration observed between the blood, breath, and tissue assays. All pair-wise combinations of alcohol assays were investigated, and the fraction of the alcohol concentration variance explained by pharmacokinetics ranged from 41.0% to 83.5%. Accounting for pharmacokinetic concentration differences, the accuracy and precision of the spectroscopic tissue assay were found to be comparable to those of the blood and breath assays.

  12. Blood glucose, lactate, pyruvate, glycerol, 3-hydroxybutyrate and acetoacetate measurements in man using a centrifugal analyser with a fluorimetric attachment.

    Science.gov (United States)

    Harrison, J; Hodson, A W; Skillen, A W; Stappenbeck, R; Agius, L; Alberti, K G

    1988-03-01

    Methods are described for the analysis of glucose, lactate, pyruvate, alanine, glycerol, 3-hydroxybutyrate and acetoacetate in perchloric acid extracts of human blood, using the Cobas Bio centrifugal analyser fitted with a fluorimetric attachment. Intra-assay and inter-assay coefficients of variation ranged from 1.9 to 7.9% and from 1.0 to 7.2% respectively. Correlation coefficients ranged from 0.96 to 0.99 against established continuous-flow and manual spectrophotometric methods. All seven metabolites can be measured using a single perchloric acid extract of 20 microliter of blood. The versatility of the assays is such that as little as 100 pmol pyruvate, 3-hydroxybutyrate or as much as 15 nmol glucose can be measured in the same 20 microliter extract.

  13. Technical note: comparison of 3 methods for analyzing areas under the curve for glucose and nonesterified fatty acids concentrations following epinephrine challenge in dairy cows.

    Science.gov (United States)

    Cardoso, F C; Sears, W; LeBlanc, S J; Drackley, J K

    2011-12-01

    The objective of the study was to compare 3 methods for calculating the area under the curve (AUC) for plasma glucose and nonesterified fatty acids (NEFA) after an intravenous epinephrine (EPI) challenge in dairy cows. Cows were assigned to 1 of 6 dietary niacin treatments in a completely randomized 6 × 6 Latin square with an extra period to measure carryover effects. Periods consisted of a 7-d (d 1 to 7) adaptation period followed by a 7-d (d 8 to 14) measurement period. On d 12, cows received an i.v. infusion of EPI (1.4 μg/kg of BW). Blood was sampled at -45, -30, -20, -10, and -5 min before EPI infusion and 2.5, 5, 10, 15, 20, 30, 45, 60, 90, and 120 min after. The AUC was calculated by incremental area, positive incremental area, and total area using the trapezoidal rule. The 3 methods resulted in different statistical inferences. When comparing the 3 methods for NEFA and glucose response, no significant differences among treatments and no interactions between treatment and AUC method were observed. For glucose and NEFA response, the method was statistically significant. Our results suggest that the positive incremental method and the total area method gave similar results and interpretation but differed from the incremental area method. Furthermore, the 3 methods evaluated can lead to different results and statistical inferences for glucose and NEFA AUC after an EPI challenge. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  14. Comparable Dietary Patterns Describe Dietary Behavior across Ethnic Groups in the Netherlands, but Different Elements in the Diet Are Associated with Glycated Hemoglobin and Fasting Glucose Concentrations.

    Science.gov (United States)

    Dekker, Louise H; van Dam, Rob M; Snijder, Marieke B; Peters, Ron J G; Dekker, Jacqueline M; de Vries, Jeanne H M; de Boer, Evelien J; Schulze, Matthias B; Stronks, Karien; Nicolaou, Mary

    2015-08-01

    Ethnic minority populations in Western societies suffer from a disproportionate burden of type 2 diabetes (T2D). Insight into the role of dietary patterns in T2D may assist public health nutrition efforts in addressing these health disparities. We explored the association between dietary patterns and biomarkers of T2D in 5 ethnic groups living in Amsterdam, Netherlands. A total of 3776 men and women aged 18-70 y of Dutch, South Asian Surinamese, African-Surinamese, Turkish, and Moroccan origin from the HELIUS (HEalthy LIfe in an Urban Setting) study were included. Diet was assessed by using a food-frequency questionnaire, and dietary patterns were derived separately per ethnic group. First, food group-based dietary patterns were derived by using principal components analysis and the association with glycated hemoglobin (HbA1c) and plasma fasting glucose was assessed by using multivariable linear regression. Second, biomarker-driven dietary patterns based on HbA1c and fasting glucose concentrations were derived by applying reduced rank regression. Two comparable food group-based dietary patterns were identified in each ethnic group: a "meat and snack" pattern and a "vegetable" pattern. The meat-and-snack pattern derived within the Dutch origin population was significantly associated with HbA1c (β = 0.09; 95% CI: 0.00, 0.19) and fasting glucose (β = 0.18; 95% CI: 0.09, 0.26) concentrations. A biomarker-derived pattern characterized by red and processed meat was observed among Dutch-origin participants; however, among ethnic minority groups, this pattern was characterized by other foods including ethnicity-specific foods (e.g., roti, couscous). Although similar food group dietary patterns were derived within 5 ethnic groups, the association of the meat-and-snack pattern with fasting glucose concentrations differed by ethnicity. Taken together with the finding of ethnic differences in biomarker-driven dietary patterns, our results imply that addressing T2D risk in

  15. The Critical Micelle Concentration of Asphaltenes as Measured by Calorimetry

    DEFF Research Database (Denmark)

    Andersen, Simon Ivar; Christensen, S. D.

    2000-01-01

    Micellization of asphaltenes in solution has been investigated using a micro calorimetric titration procedure (Andersen, S. I.; Birdi, K. S. J Colloid Interface Sci. 1991, 142, 497). The method uses the analysis of heat of dissociation and dilution of asphaltene micelles when a pure solvent (or...... solvent mixture) is titrated with a solution of asphaltene in the same solvent. The asphaltene concentration of the injected solution is at a level above the critical micelle concentration (CMC). In the present paper the procedure is applied in investigation of asphaltenes as well as subfractions...

  16. Glucose absorption in acute peritoneal dialysis.

    Science.gov (United States)

    Podel, J; Hodelin-Wetzel, R; Saha, D C; Burns, G

    2000-04-01

    During acute peritoneal dialysis (APD), it is known that glucose found in the dialysate solution contributes to the provision of significant calories. It has been well documented in continuous ambulatory peritoneal dialysis (CAPD) that glucose absorption occurs. In APD, however, it remains unclear how much glucose absorption actually does occur. Therefore, the purpose of this study was to determine whether it is appropriate to use the formula used to calculate glucose absorption in CAPD (Grodstein et al) among patients undergoing APD. Actual measurements of glucose absorption (Method I) were calculated in 9 patients undergoing APD treatment for >24 hours who were admitted to the intensive care unit. Glucose absorption using the Grodstein et al formula (Method II) was also determined and compared with the results of actual measurements. The data was then further analyzed based on the factors that influence glucose absorption, specifically dwell time and concentration. The mean total amount of glucose absorbed was 43% +/- 15%. However, when dwell time and concentration were further examined, significant differences were noted. Method I showed a cumulative increase over time. Method II showed that absorption was fixed. This suggests that with the variation in dwell time commonly seen in the acute care setting, the use of Method II may not be accurate. In each of the 2 methods, a significant difference in glucose absorption was noted when comparing the use of 1.5% and 4.25% dialysate concentrations. The established formula designed for CAPD should not be used for calculating glucose absorption in patients receiving APD because variation in dwell time and concentration should be taken into account. Because of the time constraints and staffing required to calculate each exchange individually, combined with the results of the study, we recommend the use of the percentage estimate of 40% to 50%.

  17. Concentration Polarization to Measure Nano-pore Accessibility

    NARCIS (Netherlands)

    Solsona, Miguel; Eijkel, Jan C.T.; Olthuis, Wouter; Papadimitriou, Vasileios; van den Berg, Albert; Abelmann, Leon; Weckhuysen, Bert M.; Nieuwelink, A. E.

    2017-01-01

    Understanding the deactivation process in porous catalysts is of tremendous economic significance. We demonstrate the feasibility of using the concentration polarization method to obtain the pore accessibility distribution at single particle level for the first time. By using this technique we could

  18. Measurement of Fructose-Asparagine Concentrations in Human and Animal Foods.

    Science.gov (United States)

    Wu, Jikang; Sabag-Daigle, Anice; Metz, Thomas O; Deatherage Kaiser, Brooke L; Gopalan, Venkat; Behrman, Edward J; Wysocki, Vicki H; Ahmer, Brian M M

    2018-01-10

    The food-borne bacterial pathogen, Salmonella enterica, can utilize fructose-asparagine (F-Asn) as its sole carbon and nitrogen source. F-Asn is the product of an Amadori rearrangement following the nonenzymatic condensation of glucose and asparagine. Heating converts F-Asn via complex Maillard reactions to a variety of molecules that contribute to the color, taste, and aroma of heated foods. Among these end derivatives is acrylamide, which is present in some foods, especially in fried potatoes. The F-Asn utilization pathway in Salmonella, specifically FraB, is a potential drug target because inhibition of this enzyme would lead to intoxication of Salmonella in the presence of F-Asn. However, F-Asn would need to be packaged with the FraB inhibitor or available in human foods. To determine if there are foods that have sufficient F-Asn, we measured F-Asn concentrations in a variety of human and animal foods. The 400 pmol/mg F-Asn found in mouse chow is sufficient to intoxicate a Salmonella fraB mutant in mouse models of salmonellosis, and several human foods were found to have F-Asn at this level or higher (fresh apricots, lettuce, asparagus, and canned peaches). Much higher concentrations (11 000-35 000 pmol/mg dry weight) were found in heat-dried apricots, apples, and asparagus. This report reveals possible origins of F-Asn as a nutrient source for Salmonella and identifies foods that could be used together with a FraB inhibitor as a therapeutic agent for Salmonella.

  19. The measurement of airborne rodon daughter concentrations in the atmosphere

    International Nuclear Information System (INIS)

    Ha, C.W.; Lee, J.K.; Moon, P.S.

    1979-01-01

    A simple method for determining the airborne concentration of radon daughter products has been developed, which is based on gross alpha counting of the air filter collections at several time intervals after completion of air sampling. The concentration of each nuclide is then obtained from an equation involving the alpha disintegrations, the sampling time, and the known numerical coefficients. The state of radioactive disequilibrium is also inventigated. The atmosphere sampled in the TRIGA Mark-III reactor room was largely in disequilibrium. The extent of radioactive disequilibrium between radon daughter products seems likely depend on sampling times associated with turbulence conditions. The data obtained here will certainly provide useful information on the evaluation of internal exposure and calibration of effluent monitoring instruments. (author)

  20. Time-lapse 3-D measurements of a glucose biosensor in multicellular spheroids by light sheet fluorescence microscopy in commercial 96-well plates.

    Science.gov (United States)

    Maioli, Vincent; Chennell, George; Sparks, Hugh; Lana, Tobia; Kumar, Sunil; Carling, David; Sardini, Alessandro; Dunsby, Chris

    2016-11-25

    Light sheet fluorescence microscopy has previously been demonstrated on a commercially available inverted fluorescence microscope frame using the method of oblique plane microscopy (OPM). In this paper, OPM is adapted to allow time-lapse 3-D imaging of 3-D biological cultures in commercially available glass-bottomed 96-well plates using a stage-scanning OPM approach (ssOPM). Time-lapse 3-D imaging of multicellular spheroids expressing a glucose Förster resonance energy transfer (FRET) biosensor is demonstrated in 16 fields of view with image acquisition at 10 minute intervals. As a proof-of-principle, the ssOPM system is also used to acquire a dose response curve with the concentration of glucose in the culture medium being varied across 42 wells of a 96-well plate with the whole acquisition taking 9 min. The 3-D image data enable the FRET ratio to be measured as a function of distance from the surface of the spheroid. Overall, the results demonstrate the capability of the OPM system to measure spatio-temporal changes in FRET ratio in 3-D in multicellular spheroids over time in a multi-well plate format.

  1. The analyses of measured nuclide concentration in project ISTC 2670

    International Nuclear Information System (INIS)

    Chrapciak, V.

    2006-01-01

    In this article are analyzed experiments for WWER-440 fuel and compared with theoretical results by new version of the SCALE 5 code: nuclide compositions - measurement in Kurchatov institute for 3.6% - measurement in Dimitrovgrad for 3.6% (project ISTC 2670) The focus is on modules TRITON and ORIGEN-S (Authors)

  2. Evaluation of three glucometers for whole blood glucose measurements at the point of care in preterm or low-birth-weight infants.

    Science.gov (United States)

    Hwang, Joon Ho; Sohn, Yong-Hak; Chang, Seong-Sil; Kim, Seung Yeon

    2015-08-01

    We evaluated three blood glucose self-monitoring for measuring whole blood glucose levels in preterm and low-birth-weight infants. Between December 1, 2012 and March 31, 2013, 230 blood samples were collected from 50 newborns, who weighed, ≤2,300 g or were ≤36 weeks old, in the the neonatal intensive care unit of Eulji University Hospital. Three blood glucose self-monitoring (A: Precision Pcx, Abbott; B: One-Touch Verio, Johnson & Johnson; C: LifeScan SureStep Flexx, Johnson & Johnson) were used for the blood glucose measurements. The results were compared to those obtained using laboratory equipment (D: Advia chemical analyzer, Siemens Healthcare Diagnostics Inc.). The correlation coefficients between laboratory equipment and the three blood glucose self-monitoring (A, B, and C) were found to be 0.888, 0.884, and 0.900, respectively. For glucose levels≤60 mg/dL, the correlation coefficients were 0.674, 0.687, and 0.679, respectively. For glucose levels>60 mg/dL, the correlation coefficients were 0.822, 0.819, and 0.839, respectively. All correlation coefficients were statistically significant. And the values from the blood glucose self-monitoring were not significantly different from the value of the laboratory equipment , after correcting for each device's average value (P>0.05). When using laboratory equipment (blood glucose ≤60 mg/dL), each device had a sensitivity of 0.458, 0.604, and 0.688 and a specificity of 0.995, 0.989, and 0.989, respectively. Significant difference is not found between three blood glucose self-monitoring and laboratory equipment. But correlation between the measured values from blood glucose self-monitoring and laboratory equipment is lower in preterm or low-birth-weight infants than adults.

  3. Effects of temperature on the near-infrared spectroscopic measurement of glucose

    Science.gov (United States)

    Jung, Byungjo; McShane, Michael J.; Rastegar, Sohi; Cote, Gerard L.

    1998-05-01

    The noninvasive monitoring of sugars, and in particular, glucose using near-IR (NIR) spectroscopy would be useful for a number of applications including regulating the nutrients in cell culture medium, monitoring on-line processes in the food industry, and in vivo monitoring for control of glucose in DIabetic patients. The focus of this research was the investigation of the temperature effects across a 10.6 to 40.4 degrees C range on Fourier filtered and unfiltered single-beam as well as absorbance glucose and water NIR spectra. It is known that the positions of water absorption bands centered at 1.923 and 2.623 micrometers depend heavily on temperature effects while the glucose bands are temperature insensitive across this range. The water absorption bands were shown to shift to lower wavelengths while the distance between these bands increased with increasing temperatures. Partial least squares (PLS) calibration models were constructed at five separate temperatures, 15.7, 20.5, 25.5, 35.6, and 40.4 degrees C. When absorbance spectra were used with reference scans taken at the same temperature and PLS models were used, no significant difference in the standard error of prediction (SEP) was noted with temperature. Using PLS calibration with single-beam spectra at one temperature showed large SEPs at the other temperatures. The use of Fourier filtered single-beam spectra reduced the SEP but still showed an increase as large temperature differences were produced and the filtered single beam approach did not reduce the SEP to the level achieved with the absorbance spectra.

  4. Glucose pump test can be used to measure blood flow rate of native arteriovenous fistula in chronic hemodialysis.

    Science.gov (United States)

    Yavuz, Y C; Selcuk, N Y; Altıntepe, L; Güney, I; Yavuz, S

    2018-01-01

    In chronic hemodialysis patients, the low flow of vascular access may leads to inadequate dialysis, increased rate of hospitalization, morbidity, and mortality. It was found that surveillance should be performed for native arteriovenous (AV) should not be performed for AV graft in various studies. However, surveillance was done in graft AV fistulas in most studies. Doppler ultrasonography (US) was suggested for surveillance of AV fistulas by the last vascular access guideline of National Kidney Foundation Disease Outcomes Quality Initiative (NKF KDOQI). The aim of study is to determine whether glucose pump test (GPT) is used for surveillance of native AV fistulas by using Doppler US as reference. In 93 chronic hemodialysis patients with native AV fistula, blood flow rates were measured by Doppler US and GPT. For GPT, glucose was infused to 16 mL/min by pump and was measured at basal before the infusion and 11 s after the start of the infusion by glucometer. Doppler US was done by an expert radiologist. Used statistical tests were Mann-Whitney U test, Friedman test, regression analysis, and multiple regression analysis. Median values of blood flow rates measured by GPT (707 mL/min) and by Doppler US (700 mL/min) were not different (Z = 0.414, P = 0.678). Results of GPT and Doppler US measurements were positive correlate by regression analysis. The mean GPT value of diabetic patients (n = 39; 908 mL/min) was similar to that of nondiabetic patients (n = 54; 751 mL/min; Z = 1.31, P = 0.188). GPT values measured at three different dialysis session did not differ from each other that by Friedman test (F = 0.92, P = 0.39). This showed that GPT was stable and reliable. Glucose pump test can be used to measure blood flow rate of native AV fistula. GPT is an accurate and reliable test.

  5. Glucose kinetics during fasting in young children with severe and non-severe malaria in Suriname

    NARCIS (Netherlands)

    Zijlmans, Wilco; van Kempen, Anne; Ackermans, Mariëtte; de Metz, Jesse; Kager, Piet; Sauerwein, Hans

    2008-01-01

    Fasting could be an important factor in the induction of hypoglycemia in children with malaria because fasting results in a decrease in endogenous glucose production. The influence of extended fasting on plasma glucose concentration, glucose production, and gluconeogenesis were measured using

  6. Association between the extent of urinary albumin excretion and glycaemic variability indices measured by continuous glucose monitoring.

    Science.gov (United States)

    Jin, S-M; Kim, T-H; Oh, S; Baek, J; Joung, J Y; Park, S-M; Cho, Y Y; Sohn, S Y; Hur, K Y; Lee, M-S; Lee, M-K; Kim, J H

    2015-02-01

    The contribution of glycaemic variability to the microvascular complication of diabetes has not been established. We examined whether there is an independent association between indices of glycaemic variability in continuous glucose monitoring and extent of albuminuria. A total of 173 patients with Type 2 diabetes (without insulin therapy, n = 96; with insulin therapy, n = 77) who had unexplained large fluctuations in blood glucose values underwent three-day continuous glucose monitoring. We used a multinomial logistic regression model to determine whether the indices of glycaemic variability independently affected the odds of having a spot urine albumin/creatinine ratio of 30-299 mg/g and ≥ 300 mg/g. Higher standard deviation (P = 0.002), mean of daily differences (P = 0.023) and mean amplitude of glycaemic excursion (P = 0.043) significantly increased the odds of having a urine albumin/creatinine ratio of ≥ 300 mg/g. In multivariable analysis, only higher standard deviation, but not mean amplitude of glycaemic excursion and mean of daily differences, independently increased the odds of having a urine albumin/creatinine ratio of ≥ 300 mg/g (P = 0.025). Coefficient of variation (sd/mean) was not associated with the odds of having a urine albumin/creatinine ratio of 30-299 or ≥ 300 mg/g. The independent association between standard deviation and the extent of albuminuria was lost when the measures were normalized by mean glucose level. At least in terms of relative measures of glycaemic variability, we failed to demonstrate an independent association between glycaemic variability and albuminuria extent in patients with inadequately controlled Type 2 diabetes. © 2014 The Authors. Diabetic Medicine © 2014 Diabetes UK.

  7. The product of triglycerides and glucose, a simple measure of insulin sensitivity. Comparison with the euglycemic-hyperinsulinemic clamp.

    Science.gov (United States)

    Guerrero-Romero, Fernando; Simental-Mendía, Luis E; González-Ortiz, Manuel; Martínez-Abundis, Esperanza; Ramos-Zavala, María G; Hernández-González, Sandra O; Jacques-Camarena, Omar; Rodríguez-Morán, Martha

    2010-07-01

    To meet the worldwide challenge of emerging diabetes, accessible and inexpensive tests to identify insulin resistance are needed. To evaluate the sensitivity and specificity of the product of fasting, we compared the triglycerides and glucose (TyG) index, a simple measure of insulin resistance, with the euglycemic-hyperinsulinemic clamp test. We conducted a cross-sectional study of the general population and outpatients of the Internal Medicine Department at the Medical Unit of High Specialty of the Specialty Hospital at the West National Medical Center in Guadalajara, Mexico. Eleven nonobese healthy subjects, 34 obese normal glucose tolerance individuals, 22 subjects with prediabetes, and 32 diabetic patients participated in the study. We performed a euglycemic-hyperinsulinemic clamp test. Sensitivity and specificity of the TyG index [Ln(fasting triglycerides) (mg/dl) x fasting glucose (mg/dl)/2] were measured, as well as the area under the curve of the receiver operating characteristic scatter plot and the correlation between the TyG index and the total glucose metabolism (M) rates. Pearson's correlation coefficient between the TyG index and M rates was -0.681 (P index and M rates was similar between men (-0.740) and women (-0.730), nonobese (-0.705) and obese (-0.710), and nondiabetic (-0.670) and diabetic (-0.690) individuals. The best value of the TyG index for diagnosis of insulin resistance was 4.68, which showed the highest sensitivity (96.5%) and specificity (85.0%; area under the curve + 0.858). The TyG index has high sensitivity and specificity, suggesting that it could be useful for identification of subjects with decreased insulin sensitivity.

  8. Measurement of aerosol concentration with a beta-ray gage

    International Nuclear Information System (INIS)

    Auzac, G. d'; Dubillot, J.

    1978-01-01

    Because dusts in suspension are a dangerous polluting agent, several methods have been used to monitor their concentration. Among these, the beta-ray gage enjoys a privileged position. The authors describe such a gage and discuss the conditions to be observed for it to be capable of giving results comparable to those obtained with manual gravimetric methods. The satisfactory results obtained led to standardization of the method and a whole range of instruments based on this principle are employed in pollution supervising networks and for continuously monitoring industrial emissions [fr

  9. Leucine supplementation improves adiponectin and total cholesterol concentrations despite the lack of changes in adiposity or glucose homeostasis in rats previously exposed to a high-fat diet

    Directory of Open Access Journals (Sweden)

    Donato Jose

    2011-09-01

    Full Text Available Abstract Background Studies suggest that leucine supplementation (LS has a therapeutic potential to prevent obesity and to promote glucose homeostasis. Furthermore, regular physical exercise is a widely accepted strategy for body weight maintenance and also for the prevention of obesity. The aim of this study was to determine the effect of chronic LS alone or combined with endurance training (ET as potential approaches for reversing the insulin resistance and obesity induced by a high-fat diet (HFD in rats. Methods Forty-seven rats were randomly divided into two groups. Animals were fed a control diet-low fat (n = 10 or HFD (n = 37. After 15 weeks on HFD, all rats received the control diet-low fat and were randomly divided according to treatment: reference (REF, LS, ET, and LS+ET (n = 7-8 rats per group. After 6 weeks of treatment, the animals were sacrificed and body composition, fat cell volume, and serum concentrations of total cholesterol, HDL-cholesterol, triacylglycerol, glucose, adiponectin, leptin and tumor necrosis factor-alpha (TNF-α were analyzed. Results At the end of the sixth week of treatment, there was no significant difference in body weight between the REF, LS, ET and LS+ET groups. However, ET increased lean body mass in rats (P = 0.019. In addition, ET was more effective than LS in reducing adiposity (P = 0.019, serum insulin (P = 0.022 and TNF-α (P = 0.044. Conversely, LS increased serum adiponectin (P = 0.021 levels and reduced serum total cholesterol concentration (P = 0.042. Conclusions The results showed that LS had no beneficial effects on insulin sensitivity or adiposity in previously obese rats. On the other hand, LS was effective in increasing adiponectin levels and in reducing total cholesterol concentration.

  10. INFLUENCE OF pH, TEMPERATURE AND DISSOLVED OXYGEN CONCENTRATION ON THE PRODUCTION OF GLUCOSE 6-PHOSPHATE DEHYDROGENASE AND INVERTASE BY Saccharomyces cerevisiae

    Directory of Open Access Journals (Sweden)

    J. Abrahão-Neto

    1997-03-01

    Full Text Available The effect of pH (from 4.0 to 5.0, temperature (T (from 30 oC to 40 oC and dissolved oxygen concentration (DO (from 0.2 to 6.0 mg O2/L on glucose 6-phosphate dehydrogenase (G6PDH (EC 1.1.1.49 and Invertase (EC 3.2.1.26 formation by S. cerevisiae were studied. The best culture conditions for G6PDH and Invertase formation were: 2.55 L culture medium (yeast extract, 3.0 g/L; 5peptone, 5.0 g/L; glucose, 2.0 g/L; sucrose, 15.0 g/L; Na2HPO4.12 H2O, 2.4 g/L; (NH42SO4, 5.1 g/L and MgSO4. 7H2O, 0.075 g/L; 0.45 L inoculum (0.70 g dry cell/L; pH = 4.5; T = 35 oC and DO = 4.0 mg/L. G6PDH was highly sensitive to pH, T and DO variation. The increase in G6PDH production was about three times when the DO ranged from 0.2 to 4.0 mg O2/L. Moreover, by shifting pH from 5.0 to 4.5 and temperature from 30 oC to 35 oC, G6PDH formation increased by 57% and 70%, respectively. Invertase activity (IA of whole cells decreased at least 50% at extremes values of DO (2.0 and 6.0 mg O2/L and pH (4.0 and 5.0. Furthermore, IA oscillated during the fermentation due to the glucose repression/derepression mechanism

  11. Visceral adiposity is associated with altered myocardial glucose uptake measured by (18)FDG-PET in 346 subjects with normal glucose tolerance, prediabetes, and type 2 diabetes.

    Science.gov (United States)

    Kim, Gyuri; Jo, Kwanhyeong; Kim, Kwang Joon; Lee, Yong-ho; Han, Eugene; Yoon, Hye-jin; Wang, Hye Jin; Kang, Eun Seok; Yun, Mijin

    2015-11-04

    The heart requires constant sources of energy mostly from free fatty acids (FFA) and glucose. The alteration in myocardial substrate metabolism occurs in the heart of diabetic patients, but its specific association with other metabolic variables remains unclear. We aimed to evaluate glucose uptake in hearts of subjects with normal glucose tolerance (NGT), prediabetes, and type 2 diabetes mellitus (T2DM) using [(18)F]-fluorodeoxyglucose-positron emission tomography ((18)FDG-PET) in association with visceral and subcutaneous adiposity, and metabolic laboratory parameters. A total of 346 individuals (NGT, n = 76; prediabetes, n = 208; T2DM, n = 62) in a health promotion center of a tertiary hospital were enrolled. The fasting myocardial glucose uptake, and visceral and subcutaneous fat areas were evaluated using (18)FDG-PET and abdominal computed tomography, respectively. Myocardial glucose uptake was significantly decreased in subjects with T2DM compared to the NGT or prediabetes groups (p for trend = 0.001). Multivariate linear regression analyses revealed that visceral fat area (β = -0.22, p = 0.018), fasting FFA (β = -0.39, p < 0.001), and uric acid levels (β = -0.21, p = 0.007) were independent determinants of myocardial glucose uptake. Multiple logistic analyses demonstrated that decreased myocardial glucose uptake (OR 2.32; 95% CI 1.02-5.29, p = 0.045) and visceral fat area (OR 1.02, 95% CI 1.01-1.03, p = 0.018) were associated with T2DM. Our findings indicate visceral adiposity is strongly associated with the alteration of myocardial glucose uptake evaluated by (18)FDG-PET, and its association further relates to T2DM.

  12. Glucokinase, the pancreatic glucose sensor, is not the gut glucose sensor

    DEFF Research Database (Denmark)

    Murphy, R; Tura, A; Clark, P M

    2008-01-01

    AIMS/HYPOTHESIS: The incretin hormones glucagon-like peptide-1 (GLP-1) and glucose-dependent insulinotrophic peptide (GIP) are released from intestinal endocrine cells in response to luminal glucose. Glucokinase is present in these cells and has been proposed as a glucose sensor. The physiological...... role of glucokinase can be tested using individuals with heterozygous glucokinase gene (GCK) mutations. If glucokinase is the gut glucose sensor, GLP-1 and GIP secretion during a 75 g OGTT would be lower in GCK mutation carriers compared with controls. METHODS: We compared GLP-1 and GIP concentrations...... measured at five time-points during a 75 g OGTT in 49 participants having GCK mutations with those of 28 familial controls. Mathematical modelling of glucose, insulin and C-peptide was used to estimate basal insulin secretion rate (BSR), total insulin secretion (TIS), beta cell glucose sensitivity...

  13. Preliminary evaluation of MRI-derived input function for quantitative measurement of glucose metabolism in an integrated PET-MRI

    International Nuclear Information System (INIS)

    Anazodo, Udunna; Kewin, Matthew; Finger, Elizabeth; Thiessen, Jonathan; Hadway, Jennifer; Butler, John; Pavlosky, William; Prato, Frank; Thompson, Terry; St Lawrence, Keith

    2015-01-01

    PET semi-quantitative methods such as relative uptake value can be robust but offer no biological information and do not account for intra-subject variability in tracer administration or clearance. Simultaneous multimodal measurements that combine PET and MRI not only permit crucial multiparametric measurements, it provides means of applying tracer kinetic modelling without the need for serial arterial blood sampling. In this study we adapted an image-derived input function (IDIF) method to improve characterization of glucose metabolism in an ongoing dementia study. Here we present preliminary results in a small group of frontotemporal dementia patients and controls. IDIF was obtained directly from dynamic PET data guided by regions of interest drawn on carotid vessels on high resolution T1-weighted MR Images. IDIF was corrected for contamination of non-arterial voxels. A validation of the method was performed in a porcine model in a PET-CT scanner comparing IDIF to direct arterial blood samples. Metabolic rate of glucose (CMRglc) was measured voxel-by-voxel in gray matter producing maps that were compared between groups. Net influx rate (Ki) and global mean CMRglc are reported. A good correlation (r = 0.9 p<0.0001) was found between corrected IDIF and input function measured from direct arterial blood sampling in the validation study. In 3 FTD and 3 controls, a trend towards hypometabolism was found in frontal, temporal and parietal lobes similar to significant differences previously reported by other groups. The global mean CMRglc and Ki observed in control subjects are in line with previous reports. In general, kinetic modelling of PET-FDG using an MR-IDIF can improve characterization of glucose metabolism in dementia. This method is feasible in multimodal studies that aim to combine PET molecular imaging with MRI as dynamic PET can be acquired along with multiple MRI measurements.

  14. Preliminary evaluation of MRI-derived input function for quantitative measurement of glucose metabolism in an integrated PET-MRI

    Energy Technology Data Exchange (ETDEWEB)

    Anazodo, Udunna; Kewin, Matthew [Lawson Health Research Institute, Department of Medical Biophysics, Western University, London, Ontario (Canada); Finger, Elizabeth [Department of Clinical Neurological Sciences, Western University, London, Ontario (Canada); Thiessen, Jonathan; Hadway, Jennifer; Butler, John [Lawson Health Research Institute, Department of Medical Biophysics, Western University, London, Ontario (Canada); Pavlosky, William [Diagnostic Imaging, St Joseph' s Health Care, London, Ontario (Canada); Prato, Frank; Thompson, Terry; St Lawrence, Keith [Lawson Health Research Institute, Department of Medical Biophysics, Western University, London, Ontario (Canada)

    2015-05-18

    PET semi-quantitative methods such as relative uptake value can be robust but offer no biological information and do not account for intra-subject variability in tracer administration or clearance. Simultaneous multimodal measurements that combine PET and MRI not only permit crucial multiparametric measurements, it provides means of applying tracer kinetic modelling without the need for serial arterial blood sampling. In this study we adapted an image-derived input function (IDIF) method to improve characterization of glucose metabolism in an ongoing dementia study. Here we present preliminary results in a small group of frontotemporal dementia patients and controls. IDIF was obtained directly from dynamic PET data guided by regions of interest drawn on carotid vessels on high resolution T1-weighted MR Images. IDIF was corrected for contamination of non-arterial voxels. A validation of the method was performed in a porcine model in a PET-CT scanner comparing IDIF to direct arterial blood samples. Metabolic rate of glucose (CMRglc) was measured voxel-by-voxel in gray matter producing maps that were compared between groups. Net influx rate (Ki) and global mean CMRglc are reported. A good correlation (r = 0.9 p<0.0001) was found between corrected IDIF and input function measured from direct arterial blood sampling in the validation study. In 3 FTD and 3 controls, a trend towards hypometabolism was found in frontal, temporal and parietal lobes similar to significant differences previously reported by other groups. The global mean CMRglc and Ki observed in control subjects are in line with previous reports. In general, kinetic modelling of PET-FDG using an MR-IDIF can improve characterization of glucose metabolism in dementia. This method is feasible in multimodal studies that aim to combine PET molecular imaging with MRI as dynamic PET can be acquired along with multiple MRI measurements.

  15. The concentration of glucose, insuline, thyroxine (T4), triiodthyronine (T3) and gastrine in the maternal blood, in the umbilical cord blood of their outcomes in the neonatal blood samples

    International Nuclear Information System (INIS)

    Osuch-Jaczewska, R.; Tomala, J.; Adamska, S.; Bielecka, W.; Mikulska, M.; Kalacinska, M.; Sieron, G.

    1978-01-01

    In the blood samples collected from the mothers, from the umbilical cord of their outcomes and from these neonates after 24 hours of life following estimations were performed collaterally: The concentration of insulin in 50 mothers and their fetuses and in 34 neonates, concentration of thyroxine (T 4 ) in 70 mothers and their fetuses and in 32 neonates, triiodothyronine binding coefficient (WWT 3 ) in 60 mothers and their fetuses and neonates, concentration of gastrine in 23 mothers and their fetuses and in 5 neonates. Besides that the concentration of glucose in total blood was established in 300 mothers - their fetuses and neonates. The insuline, WWT 3 and gastrine were estimated by radioimmune techniques and T 4 by radiocompetitive technique. The glucose concentration - with the aid of o-toluidine method. Basing on the results, the paper suggests that the fetus and the newborn represent independent unit in the aspect of regulation of the glucose concentration, secretion of insuline, T 3 , T 4 and gastrine, notwithstanding the possibility of transplacental passage of these hormones exists the correlation coefficients between the maternal and fetal blood concentrations of insuline, T 4 and WWT 3 were significant. The cord-blood glucose concentration exhibits a marked correlation with the maternal glicemia. Physiologic, asymptomatic hyperinsulinemia and hyperthyreosis and an increase of gastrine concentration demonstrate the presence, in the fetal and neonatal organisms, of certain compensatory-regulating mechanisms stimulating and inhibiting with feed-back properties, which guarantee the environmental homeostasis. (author)

  16. In vivo cardiac glucose metabolism in the high-fat fed mouse: Comparison of euglycemic–hyperinsulinemic clamp derived measures of glucose uptake with a dynamic metabolomic flux profiling approach

    International Nuclear Information System (INIS)

    Kowalski, Greg M.; De Souza, David P.; Risis, Steve; Burch, Micah L.; Hamley, Steven; Kloehn, Joachim; Selathurai, Ahrathy; Lee-Young, Robert S.; Tull, Dedreia; O'Callaghan, Sean; McConville, Malcolm J.; Bruce, Clinton R.

    2015-01-01

    Rationale: Cardiac metabolism is thought to be altered in insulin resistance and type 2 diabetes (T2D). Our understanding of the regulation of cardiac substrate metabolism and insulin sensitivity has largely been derived from ex vivo preparations which are not subject to the same metabolic regulation as in the intact heart in vivo. Studies are therefore required to examine in vivo cardiac glucose metabolism under physiologically relevant conditions. Objective: To determine the temporal pattern of the development of cardiac insulin resistance and to compare with dynamic approaches to interrogate cardiac glucose and intermediary metabolism in vivo. Methods and results: Studies were conducted to determine the evolution of cardiac insulin resistance in C57Bl/6 mice fed a high-fat diet (HFD) for between 1 and 16 weeks. Dynamic in vivo cardiac glucose metabolism was determined following oral administration of [U- 13 C] glucose. Hearts were collected after 15 and 60 min and flux profiling was determined by measuring 13 C mass isotopomers in glycolytic and tricarboxylic acid (TCA) cycle intermediates. Cardiac insulin resistance, determined by euglycemic–hyperinsulinemic clamp, was evident after 3 weeks of HFD. Despite the presence of insulin resistance, in vivo cardiac glucose metabolism following oral glucose administration was not compromised in HFD mice. This contrasts our recent findings in skeletal muscle, where TCA cycle activity was reduced in mice fed a HFD. Similar to our report in muscle, glucose derived pyruvate entry into the TCA cycle in the heart was almost exclusively via pyruvate dehydrogenase, with pyruvate carboxylase mediated anaplerosis being negligible after oral glucose administration. Conclusions: Under experimental conditions which closely mimic the postprandial state, the insulin resistant mouse heart retains the ability to stimulate glucose metabolism. - Highlights: • Insulin clamp was used to determine the evolution of cardiac insulin

  17. In vivo cardiac glucose metabolism in the high-fat fed mouse: Comparison of euglycemic–hyperinsulinemic clamp derived measures of glucose uptake with a dynamic metabolomic flux profiling approach

    Energy Technology Data Exchange (ETDEWEB)

    Kowalski, Greg M., E-mail: greg.kowalski@deakin.edu.au [Centre for Physical Activity and Nutrition Research, School of Exercise and Nutrition Sciences, Deakin University, Burwood, Victoria 3125 (Australia); De Souza, David P. [Metabolomics Australia, Department of Biochemistry and Molecular Biology, Bio21 Institute of Molecular Science and Biotechnology, University of Melbourne, Parkville, Victoria 3010 (Australia); Risis, Steve [Cellular and Molecular Metabolism Laboratory, Baker IDI Heart and Diabetes Institute, Melbourne, Victoria 3004 (Australia); Burch, Micah L. [Brigham and Women' s Hospital, Department of Medicine, Boston, MA (United States); Hamley, Steven [Centre for Physical Activity and Nutrition Research, School of Exercise and Nutrition Sciences, Deakin University, Burwood, Victoria 3125 (Australia); Kloehn, Joachim [Metabolomics Australia, Department of Biochemistry and Molecular Biology, Bio21 Institute of Molecular Science and Biotechnology, University of Melbourne, Parkville, Victoria 3010 (Australia); Selathurai, Ahrathy [Centre for Physical Activity and Nutrition Research, School of Exercise and Nutrition Sciences, Deakin University, Burwood, Victoria 3125 (Australia); Lee-Young, Robert S. [Cellular and Molecular Metabolism Laboratory, Baker IDI Heart and Diabetes Institute, Melbourne, Victoria 3004 (Australia); Tull, Dedreia; O' Callaghan, Sean; McConville, Malcolm J. [Metabolomics Australia, Department of Biochemistry and Molecular Biology, Bio21 Institute of Molecular Science and Biotechnology, University of Melbourne, Parkville, Victoria 3010 (Australia); Bruce, Clinton R. [Centre for Physical Activity and Nutrition Research, School of Exercise and Nutrition Sciences, Deakin University, Burwood, Victoria 3125 (Australia)

    2015-08-07

    Rationale: Cardiac metabolism is thought to be altered in insulin resistance and type 2 diabetes (T2D). Our understanding of the regulation of cardiac substrate metabolism and insulin sensitivity has largely been derived from ex vivo preparations which are not subject to the same metabolic regulation as in the intact heart in vivo. Studies are therefore required to examine in vivo cardiac glucose metabolism under physiologically relevant conditions. Objective: To determine the temporal pattern of the development of cardiac insulin resistance and to compare with dynamic approaches to interrogate cardiac glucose and intermediary metabolism in vivo. Methods and results: Studies were conducted to determine the evolution of cardiac insulin resistance in C57Bl/6 mice fed a high-fat diet (HFD) for between 1 and 16 weeks. Dynamic in vivo cardiac glucose metabolism was determined following oral administration of [U-{sup 13}C] glucose. Hearts were collected after 15 and 60 min and flux profiling was determined by measuring {sup 13}C mass isotopomers in glycolytic and tricarboxylic acid (TCA) cycle intermediates. Cardiac insulin resistance, determined by euglycemic–hyperinsulinemic clamp, was evident after 3 weeks of HFD. Despite the presence of insulin resistance, in vivo cardiac glucose metabolism following oral glucose administration was not compromised in HFD mice. This contrasts our recent findings in skeletal muscle, where TCA cycle activity was reduced in mice fed a HFD. Similar to our report in muscle, glucose derived pyruvate entry into the TCA cycle in the heart was almost exclusively via pyruvate dehydrogenase, with pyruvate carboxylase mediated anaplerosis being negligible after oral glucose administration. Conclusions: Under experimental conditions which closely mimic the postprandial state, the insulin resistant mouse heart retains the ability to stimulate glucose metabolism. - Highlights: • Insulin clamp was used to determine the evolution of cardiac

  18. Mulberry-extract improves glucose tolerance and decreases insulin concentrations in normoglycaemic adults: Results of a randomised double-blind placebo-controlled study.

    Directory of Open Access Journals (Sweden)

    Mark Lown

    Full Text Available High sugar and refined carbohydrate intake is associated with weight gain, increased incidence of diabetes and is linked with increased cardiovascular mortality. Reducing the health impact of poor quality carbohydrate intake is a public health priority. Reducose, a proprietary mulberry leaf extract (ME, may reduce blood glucose responses following dietary carbohydrate intake by reducing absorption of glucose from the gut.A double-blind, randomised, repeat measure, phase 2 crossover design was used to study the glycaemic and insulinaemic response to one reference product and three test products at the Functional Food Centre, Oxford Brooks University, UK. Participants; 37 adults aged 19-59 years with a BMI ≥ 20kg/m2 and ≤ 30kg/m2. The objective was to determine the effect of three doses of mulberry-extract (Reducose versus placebo on blood glucose and insulin responses when co-administered with 50g maltodextrin in normoglycaemic healthy adults. We also report the gastrointestinal tolerability of the mulberry extract.Thirty-seven participants completed the study: The difference in the positive Incremental Area Under the Curve (pIAUC (glucose (mmol / L x h for half, normal and double dose ME compared with placebo was -6.1% (-18.2%, 5.9%; p = 0.316, -14.0% (-26.0%, -2.0%; p = 0.022 and -22.0% (-33.9%, -10.0%; p<0.001 respectively. The difference in the pIAUC (insulin (mIU / L x h for half, normal and double dose ME compared with placebo was -9.7% (-25.8%, 6.3%; p = 0.234, -23.8% (-39.9%, -7.8%; p = 0.004 and -24.7% (-40.8%, -8.6%; p = 0.003 respectively. There were no statistically significant differences between any of the 4 groups in the odds of experiencing one or more gastrointestinal symptoms (nausea, abdominal cramping, distension or flatulence.Mulberry leaf extract significantly reduces total blood glucose rise after ingestion of maltodextrin over 120 minutes. The pattern of effect demonstrates a classical dose response curve with

  19. The measurement of dissolved and gaseous carbon dioxide concentration

    Science.gov (United States)

    Zosel, J.; Oelßner, W.; Decker, M.; Gerlach, G.; Guth, U.

    2011-07-01

    In this review the basic principles of carbon dioxide sensors and their manifold applications in environmental control, biotechnology, biology, medicine and food industry are reported. Electrochemical CO2 sensors based on the Severinghaus principle and solid electrolyte sensors operating at high temperatures have been manufactured and widely applied already for a long time. Besides these, nowadays infrared, non-dispersive infrared and acoustic CO2 sensors, which use physical measuring methods, are being increasingly used in some fields of application. The advantages and drawbacks of the different sensor technologies are outlined. Electrochemical sensors for the CO2 measurement in aqueous media are pointed out in more detail because of their simple setup and the resulting low costs. A detailed knowledge of the basic detection principles and the windows for their applications is necessary to find an appropriate decision on the technology to be applied for measuring dissolved CO2. In particular the pH value and the composition of the analyte matrix exert important influence on the results of the measurements.

  20. The measurement of dissolved and gaseous carbon dioxide concentration

    International Nuclear Information System (INIS)

    Zosel, J; Oelßner, W; Decker, M; Gerlach, G; Guth, U

    2011-01-01

    In this review the basic principles of carbon dioxide sensors and their manifold applications in environmental control, biotechnology, biology, medicine and food industry are reported. Electrochemical CO 2 sensors based on the Severinghaus principle and solid electrolyte sensors operating at high temperatures have been manufactured and widely applied already for a long time. Besides these, nowadays infrared, non-dispersive infrared and acoustic CO 2 sensors, which use physical measuring methods, are being increasingly used in some fields of application. The advantages and drawbacks of the different sensor technologies are outlined. Electrochemical sensors for the CO 2 measurement in aqueous media are pointed out in more detail because of their simple setup and the resulting low costs. A detailed knowledge of the basic detection principles and the windows for their applications is necessary to find an appropriate decision on the technology to be applied for measuring dissolved CO 2 . In particular the pH value and the composition of the analyte matrix exert important influence on the results of the measurements. (topical review)

  1. Quality control of the concentration measurement of specific radioactive isotopes

    International Nuclear Information System (INIS)

    Loria, Luis Guillermo; Badilla, Mauricio

    2008-01-01

    The counting efficiency of a gamma spectroscopy chain with a Ge (H.p) detector was measured. The Monte Carlo simulation and standard reference materials, in order to calculate the specific activity from 4 reference materials, and from intercomparison samples were used. The purpose was to evaluate the analytical results obtained in the Laboratorio de Espectroscopia Gamma. (author) [es

  2. Fluxes of chemically reactive species inferred from mean concentration measurements

    NARCIS (Netherlands)

    Galmarini, S.; Vilà-Guerau De Arellano, J.; Duyzer, J.H.

    1997-01-01

    A method is presented for the calculation of the fluxes of chemically reactive species on the basis of routine measurements of meteorological variables and chemical species. The method takes explicity into account the influence of chemical reactions on the fluxes of the species. As a demonstration

  3. High glucose impairs superoxide production from isolated blood neutrophils

    DEFF Research Database (Denmark)

    Perner, A; Nielsen, S E; Rask-Madsen, J

    2003-01-01

    Superoxide (O(2)(-)), a key antimicrobial agent in phagocytes, is produced by the activity of NADPH oxidase. High glucose concentrations may, however, impair the production of O(2)(-) through inhibition of glucose-6-phosphate dehydrogenase (G6PD), which catalyzes the formation of NADPH. This study...... measured the acute effects of high glucose or the G6PD inhibitor dehydroepiandrosterone (DHEA) on the production of O(2)(-) from isolated human neutrophils....

  4. Comparison of three commercially available prescription diet regimens on short-term post-prandial serum glucose and insulin concentrations in healthy cats.

    Science.gov (United States)

    Mori, A; Sako, T; Lee, P; Nishimaki, Y; Fukuta, H; Mizutani, H; Honjo, T; Arai, T

    2009-10-01

    Dietary therapy is an important treatment component for diabetes mellitus (DM). In this study, the impact of three different commercially available diet regiments (1 general use and 2 aimed for treating obesity and DM) on short-term post-prandial serum glucose and insulin concentrations of five healthy cats to better understand what impact each of these diets may have for diabetic cats. The diet regiments used in this study were as follows: C/D dry (General Use- Low protein, High fat, High carbohydrate, and Low fiber), M/D dry (DM- High protein, High fat, Low carbohydrate, and High Fiber), and W/D dry (DM- Low Protein, Low Fat, High Carbohydrate, and High Fiber). No significant difference in post-prandial serum glucose levels were observed with the C/D (84.6 +/- 1.5 mg/dl) and W/D (83.8 +/- 1.4 mg/dl) dry diets when compared to pre-prandial fasting levels (83.9 +/- 1.4 mg/dl). However, a significant reduction was observed with the M/D diet (78.9 +/- 0.8 mg/dl) which had 50-60% less carbohydrates than either C/D or W/D diet. Unlike what was observed with post-prandial glucose levels, an interesting pattern emerged with post-prandial insulin levels, which were increasing with W/D, C/D, and M/D diets in that order (1.1 +/- 0.2, 1.7 +/- 0.2, and 2.3 +/- 0.2 ng/ml respectively). Most surprising, though, was the fact that the W/D diet did not seem to stimulate insulin secretion as compared to pre-prandial levels (1.1 +/- 0.1 ng/ml) in healthy cats. Interestingly, the W/D diet had high levels of carbohydrate and low levels of protein. Coincidentally, the only diet (M/D) which had a significant reduction in post-prandial glucose also showed the highest increase in post-prandial insulin in healthy cats. Therefore, dietary amounts of carbohydrate, fat, protein and fiber can all have an individual impact on post-prandial glycemia and subsequent insulin requirement levels. Just as concepts regarding dietary management of people with DM are evolving, investigators are

  5. Investigation of 18F-2-deoxyglucose for the measure of myocardial glucose metabolism

    International Nuclear Information System (INIS)

    Phelps, M.E.; Hoffman, E.J.; Selin, C.; Huang, S.C.; Robinson, G.; MacDonald, N.; Schelbert, H.R.; Kuhl, D.E.

    1977-01-01

    18 F labeled 2-deoxyglucose ( 18 FDG) was studied as a glucose analog. Myocardial uptake and retention, blood clearance, species (dog, monkey, man) dependence and effect of diet on uptake were investigated. Normal myocardial uptake of 18 FDG was 3 to 4% in dog and monkey and 1 to 4% of injected dose in man compared to brain uptake of 2% in dog, 5 to 6% in monkey and 4 to 8% in man. The metabolic rate (MR) for glucose in non-fasting (glycolytic state) was 2.8 times greater than in fasting (ketogenic state). Human subjects showed higher myocardial uptake after a normal meal than after meal containing mostly free fatty acids (FFA). Blood clearance was rapid with initial clearance t 1 / 2 of 0.2 to 0.3 min followed by a t 1 / 2 of 8.4 +- 1.2 min in dog and 11.6 +- 1.1 min in man. A small third component had a t 1 / 2 of 59 +- 10 min and 88 +- 4 min in dog and man, respectively. High image contrast ratios between heart and blood (dog 3.5/1; man 14/1), heart and lung (dog 9/1; man 20/1), heart and liver (dog 15/1; man 10/1) were found with the ECAT positron tomograph. 18 FDG was found to be rapidly taken up by the myocardium without any significant tissue clearance over a 4 hour period. 18 FDG is transported, phosphorylated to 18 FDG-6-PO 4 and trapped in myocardial cells in the same manner as has been found for brain and exhibits excellent imaging properties. Determination of glucose and FFA MR in vivo with ECT provides a method for investigation and assessment of changing aerobic and anaerobic metabolic rates in ischemic heart disease in man

  6. Measurement of radon concentration in Taiz city dwellings-yemen

    International Nuclear Information System (INIS)

    Ali, Taher M.; Ahmed, Hayel A.; Ismail, Rokhsana M.

    2001-01-01

    Radon gas considered being a high part of natural radiation background. Emitting alpha particles; radon daughters may be deposited into the lungs and cause health hazards. For this reason, estimation of radon levels in dwellings was done in many countries. In our country, Radon group in the Department of physics, University of Aden has been studied radon level in Aden dwelling. The present study is about the radon level in Taiz City - Yemen. Passive diffusion dosimeters containing (SSNTD s ) Cr - 39 detectors were used in the present work. 125 dosimeters were distributed into dwellings of ten regions in Taiz City. Results obtained show that Rn 222 levels vary between 4 Bq/m 3 and 99 Bq/m 3 . The average concentration in Al-Hasseb district is 23 Bq/m 3 and in Algumhuri hospital district is 53 Bq/m 3 . In other regions it varies between the two values. Whereas the general average in the Taiz City is 34 Bq/m 3 . (author)

  7. Is lowering reducing sugars concentration in French fries an effective measure to reduce acrylamide concentration in food service establishments?

    Science.gov (United States)

    Sanny, M; Jinap, S; Bakker, E J; van Boekel, M A J S; Luning, P A

    2012-12-01

    The objective of this study was to obtain insight into the actual effectiveness of lowering reducing sugars concentration in par-fried potato strips on the concentration and variation of acrylamide in French fries prepared in real-life situations in food service establishments. Acrylamide, frying time, frying temperature, and reducing sugars were measured and characteristics of fryers were recorded. Data showed that the use of par-fried potato strips with lower concentrations of reducing sugars than the commonly used potato strips was an effective measure to reduce acrylamide concentrations in French fries prepared under standardised frying conditions. However, there was still large variation in the acrylamide concentrations in French fries, although the variation in reducing sugars concentrations in low and normal types of par-fried potato strips was very small and the frying conditions were similar. Factors that could affect the temperature-time profile of frying oil were discussed, such as setting a lower frying temperature at the end than at the start of frying, product/oil ratio and thawing practice. These need to be controlled in daily practice to reduce variation in acrylamide. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. Prevalence of subclinical ketosis in dairy cattle in the Southwestern Iran and detection of cutoff point for NEFA and glucose concentrations for diagnosis of subclinical ketosis.

    Science.gov (United States)

    Asl, Ardavan Nowroozi; Nazifi, Saeed; Ghasrodashti, Abbas Rowshan; Olyaee, Ahad

    2011-06-01

    Subclinical ketosis (SCK) is simply a condition marked by increased levels of circulating ketone bodies without the presence of the clinical signs of ketosis. Subclinical ketosis can cause economic losses through decreased milk production and association with preparturient diseases. Limited information is available regarding the prevalence of SCK in dairy herds in Southwestern Iran. The objectives of this study were (i) determination of the cutoff point of nonesterified fatty acids (NEFAs) and glucose concentrations for diagnosis of SCK using receiver operating characteristic (ROC) analysis, and (ii) determination of prevalence of subclinical ketosis in apparently healthy dairy cattle in Southwestern Iran. From October to December 2009, a total of 100 clinically healthy multiparous Holstein cows (3-8 years old) were randomly selected from 16 dairy herds around Kazerun, Fars Province, Iran. The cows had two-six lactations, with body weight ranging from 500 to 650 kg. Blood samples for each cow were taken at 2, 4 and 6 weeks post parturition and 3-4h after the morning feeding. The optimal cutoff point was set, by the ROC method, to >0.26 mmol/L for NEFA, and ketosis in all of the 2, 4 and 6 weeks postpartum. The results suggest that, a cut-off point of 0.26 mmol/L for NEFA concentrations can be used during early lactation for diagnosis of subclinical ketosis and making management decisions for prevention and treatment. Glucose cannot be a good criterion for diagnosis of SCK and it does not appear to be useful for monitoring subclinical ketosis. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. Lifestyle, glucose regulation and the cognitive effects of glucose load in middle-aged adults.

    Science.gov (United States)

    Riby, Leigh M; McLaughlin, Jennifer; Riby, Deborah M; Graham, Cheryl

    2008-11-01

    Interventions aimed at improving glucose regulatory mechanisms have been suggested as a possible source of cognitive enhancement in the elderly. In particular, previous research has identified episodic memory as a target for facilitation after either moderate increases in glycaemia (after a glucose drink) or after improvements in glucose regulation. The present study aimed to extend this research by examining the joint effects of glucose ingestion and glucose regulation on cognition. In addition, risk factors associated with the development of poor glucose regulation in middle-aged adults were considered. In a repeated measures design, thirty-three middle-aged adults (aged 35-55 years) performed a battery of memory and non-memory tasks after either 25 g or 50 g glucose or a sweetness matched placebo drink. To assess the impact of individual differences in glucose regulation, blood glucose measurements were taken on four occasions during testing. A lifestyle and diet questionnaire was also administered. Consistent with previous research, episodic memory ability benefited from glucose ingestion when task demands were high. Blood glucose concentration was also found to predict performance across a number of cognitive domains. Interestingly, the risk factors associated with poor glucose regulation were linked to dietary impacts traditionally associated with poor health, e.g. the consumption of high-sugar sweets and drinks. The research replicates earlier work suggesting that task demands are critical to the glucose facilitation effect. Importantly, the data demonstrate clear associations between elevated glycaemia and relatively poor cognitive performance, which may be partly due to the effect of dietary and lifestyle factors.

  10. Concentration measurements of biodiesel in engine oil and in diesel fuel

    International Nuclear Information System (INIS)

    Mäder, A; Eskiner, M; Burger, C; Rossner, M; Krahl, J; Ruck, W

    2012-01-01

    This work comprised a method for concentration measurements of biodiesel in engine oil as well as biodiesel in diesel fuel by a measurement of the permittivity of the mixture at a frequency range from 100 Hz to 20 kHz. For this purpose a special designed measurement cell with high sensitivity was designed. The results for the concentration measurements of biodiesel in the engine oil and diesel fuel shows linearity to the measurement cell signal for the concentration of biodiesel in the engine oil between 0.5% Vol. to 10% Vol. and for biodiesel in the diesel fuel between 0% Vol. to 100% Vol. The method to measure the concentration of biodiesel in the engine oil or the concentration of biodiesel in the diesel fuel is very accurate and low concentration of about 0.5% Vol. biodiesel in engine oil or in diesel fuel can be measured with high accuracy.

  11. Evolutionary engineering of a glycerol-3-phosphate dehydrogenase-negative, acetate-reducing Saccharomyces cerevisiae strain enables anaerobic growth at high glucose concentrations

    Science.gov (United States)

    Guadalupe-Medina, Víctor; Metz, Benjamin; Oud, Bart; van Der Graaf, Charlotte M; Mans, Robert; Pronk, Jack T; van Maris, Antonius J A

    2014-01-01

    Glycerol production by Saccharomyces cerevisiae, which is required for redox-cofactor balancing in anaerobic cultures, causes yield reduction in industrial bioethanol production. Recently, glycerol formation in anaerobic S. cerevisiae cultures was eliminated by expressing Escherichia coli (acetylating) acetaldehyde dehydrogenase (encoded by mhpF) and simultaneously deleting the GPD1 and GPD2 genes encoding glycerol-3-phosphate dehydrogenase, thus coupling NADH reoxidation to reduction of acetate to ethanol. Gpd– strains are, however, sensitive to high sugar concentrations, which complicates industrial implementation of this metabolic engineering concept. In this study, laboratory evolution was used to improve osmotolerance of a Gpd– mhpF-expressing S. cerevisiae strain. Serial batch cultivation at increasing osmotic pressure enabled isolation of an evolved strain that grew anaerobically at 1 M glucose, at a specific growth rate of 0.12 h−1. The evolved strain produced glycerol at low concentrations (0.64 ± 0.33 g l−1). However, these glycerol concentrations were below 10% of those observed with a Gpd+ reference strain. Consequently, the ethanol yield on sugar increased from 79% of the theoretical maximum in the reference strain to 92% for the evolved strains. Genetic analysis indicated that osmotolerance under aerobic conditions required a single dominant chromosomal mutation, and one further mutation in the plasmid-borne mhpF gene for anaerobic growth. PMID:24004455

  12. Second trimester amniotic fluid glucose, uric acid, phosphate, potassium, and sodium concentrations in relation to maternal pre-pregnancy BMI and birth weight centiles.

    Science.gov (United States)

    Fotiou, Maria; Michaelidou, Alexandra Maria; Athanasiadis, Apostolos P; Menexes, Georgios; Symeonidou, Maria; Koulourida, Vasiliki; Ganidou, Maria; Theodoridis, Theodoros D; Tarlatzis, Basil C

    2015-05-01

    To study the evolution profile of amniotic fluid (AF) glucose, uric acid, phosphate, potassium, and sodium, in the second trimester of pregnancy, and explore the possible relations between the concentration of these components and maternal, as well as neonatal characteristics. AF of 52 pregnant women was analyzed using an automatic multichannel analyzer. Maternal age, pre-pregnancy Body Mass Index (BMI), inter-pregnancy intervals, and smoking status were derived from questionnaires. Information on pregnancy and delivery was collected from medical records. Uric acid increased (r = 0.423, p pregnancy (r = -0.590, p pregnancy BMI was significantly correlated with AF uric acid concentration (r = 0.460, p sodium (r = 0.254, p = 0.070) levels. Multiple linear regression indicated that mid-trimester AF uric acid and phosphate levels were significantly related to birth weight centiles (R(2)( )= 0.345, p pregnancy BMI is significantly correlated with AF uric acid concentration, and (c) in appropriate for gestational age infants, AF phosphate and uric acid levels may serve as potential biomarkers of birth weight centiles. Further studies on AF composition may help to unravel the biochemical pathways underlying fetal development and could offer insight on the potential impact of maternal nutritional management on fetal growth regulation.

  13. The measurement of radon concentration of soil in a civil construction site

    International Nuclear Information System (INIS)

    Liu Hanbin; Fan Guang

    2004-01-01

    Radon is one of radioactive resources which do harm to human body. Therefore, its concentration in the soil should be measured before the civil construction works. Code for Indoor Environmental Pollution Control of Civil Building Engineering (GB50325-2001) is the main norm used for soil radon concentration measurement. By using FD-3017 RaA radon measuring equipment, the soil radon concentration in a civil building engineering site has been measured, the result shows that the concentration is lower than the regional average value, radon protective measures should not be installed in that site. (authors)

  14. System for measuring of air concentration in air-steam mixture during the transients

    International Nuclear Information System (INIS)

    Gorbenko, Gennady A.; Gakal, Pavlo G.; Epifanov, Konstantin S.; Osokin, Gennady V.; Smirnov, Sergey V.

    2006-01-01

    Description of system for air concentration measuring in air-steam mixture during the transients is represented. Air concentration measuring is based on discrete sampling method. The measuring system consists of sampler, transport pipeline, distributor and six measuring vessels. From the sampler air-steam mixture comes to distributor through transport pipeline and fills consecutively the measuring vessels. The true air concentration in place of measurement was defined based on measured air concentration in samples taken from measuring vessels. For this purpose, the mathematical model of transients in measuring system was developed. Air concentration transient in air-steam mixture in place of measurement was described in mathematical model by air concentration time-dependent function. The function parameters were defined based on air concentration measured in samples taken from measuring vessels. Estimated error of air concentration identification was about 10%. Measuring system was used in experiments on EREC BKV-213 test facility intended for testing of VVER-440/V-213 reactor barbotage-vacuum system

  15. The effect of glucose stimulation on 45calcium uptake of rat pancreatic islets and their total calcium content as measured by a fluorometric micro-method

    International Nuclear Information System (INIS)

    Wolters, G.H.J.; Wiegman, J.B.; Konijnendijk, W.

    1982-01-01

    Glucose-stimulated 45 calcium uptake and total calcium content of rat pancreatic islets has been studied, using a new fluorometric micro-method to estimate total calcium. Extracellular calcium was separated from incubated tissue by a rapid micro-filtration procedure. Islets incubated up to 60 min with calcium chloride 2.5 mmol/l and glucose 2.5 mmol/l maintained the same calcium content (670 +- 7.5 pmol/μg DNA). When the glucose concentration was raised to 15 mmol/l no change in the total calcium content could be detected. On incubation with glucose 2.5 mmol/l in the absence of calcium, the calcium content decreased to 488 +- 27 pmol/μg DNA. On incubation with 45 calcium chloride 2.5 mmol/l for 5 or 30 min at 2.5 mmol/l glucose, islets exchanged 21 +- 2 and 28 +- 1% of their total calcium content and, at 15 mmol/l glucose, 30 +- 3 and 45 +- 2%, respectively. Thus, islet calcium has a high turn-over rate. Glucose stimulation results in an increase of the calcium uptake without enhancing the total calcium content and hence must increase the calcium-exchangeable pool. (orig.)

  16. Reliability of point-of-care hematocrit, blood gas, electrolyte, lactate and glucose measurement during cardiopulmonary bypass.

    Science.gov (United States)

    Steinfelder-Visscher, J; Weerwind, P W; Teerenstra, S; Brouwer, M H J

    2006-01-01

    Recently, the GEM Premier blood gas analyser was upgraded to the GEM Premier 3000. In addition to pH, pCO2, pO2, Na+, K+, Ca2+, and hematocrit measurement, glucose and lactate can be measured on the GEM Premier 3000. In this prospective clinical study, the analytical performance of the GEM Premier 3000 was compared with the Ciba Corning 865 analyser for blood gas/electrolytes/metabolites, and for hematocrit with the Sysmex XE 2100 instrument. During a 6-month period, 127 blood samples were analysed on both the GEM Premier 3000 analyser and our laboratory analysers (Ciba Corning 865/Sysmex 2100 instrument), and compared using the agreement analysis for quantitative data. With the exception of K+, the other parameters (pCO2, pO2, Na+, Ca2+, hematocrit, glucose, and lactate) can be described in terms of the mean and standard deviation of the differences. For K+ measurement, a clear linear trend (r=0.79, panalyser seems to be suitable for point-of-care testing of electrolytes, metabolites, and blood gases during cardiopulmonary bypass. However, its downward bias in hematocrit values below 30% suggests that using the GEM Premier 3000 as a transfusion trigger leads to overtreatment with packed red cells.

  17. Spatial relationship between tumor perfusion and endogeneous glucose distribution

    International Nuclear Information System (INIS)

    Schroeder, T.; Larrier, N.; Viglianti, B.; Rabbani, Z.N.; Peltz, C.; Vujascovic, Z.; Dewhirst, M.W.

    2003-01-01

    Earlier studies detecting glucose in tissue and solid tumors by bioluminescence imaging suggested, that glucose distribution patterns may be spatially related to functional vascularity. The purpose of this study was to evaluate this relationship by comparing glucose distribution patterns as determined by bioluminescence imaging to perfusion patterns of endogeneous Hoechst 33342 in rats bearing mammary carcinomas. R 3230 mammary carcinoma cells have been implanted subcutaneously into 7 female Fischer 344 rats. Two months post implantation, after injection of Hoechst 33342 the tumors were removed and snap frozen to conserve metabolite levels. Concomitantly, blood was sampled from the animals for analysis of glucose concentrations using a micodialysis analyzer. Cryosections of the tumors have been prepared, and every slice has been analyzed for both, Hoechst binding by fluorescence microscopy, and for glucose distribution patterns using bioluminescence imaging. In many cases vascular structures could be retrieved by the spatial pattern of glucose distribution. In some cases however, higher glucose concentrations could be found independent from Hoechst signal. On the other hand, regions of high Hoechst signal are not necessarily correlated with high glucose concentrations. When comparing blood and tissue glucose levels, tissue glucose content as measured with bioluminescence imaging (1.9-3.5 mM) is considerably lower than blood glucose (5.6-8.0 mM), demonstrating the expected gradient from blood to tissue. This study demonstrates the feasibility of monitoring glucose gradients in relation to functional vasculature throughout the body, from blood down to tissue or tumor and further, throughout the microenvironment of the solid tumor. Glucose distribution patterns may be an important tool in perfusion studies, e. g. in detecting the direction of blood flow in ex-vivo samples or in estimating glucose consumption rates of tumor cells adjacent to or in between perfused

  18. Glucose metabolism of fetal rat brain in utero, measured with labeled deoxyglucose

    Energy Technology Data Exchange (ETDEWEB)

    Dyve, S [Department of General Physiology and Biophysics, Panum Institute, Copenhagen (Denmark); Gjedde, A [Positron Imaging Laboratories, McConnell Brain Imaging Center, Montreal, Quebec (Canada)

    1991-01-01

    Mammals have low cerebral metabolic rates immediately after birth and, by inference, also before birth. In this study, we extended the deoxyglucose method to the fetal rat brain in utero. Rate constants for deoxyglucose transfer across the maternal placental and fetal blood-brain barriers, and lumped constant, have not been reported. Therefore, we applied a new method of determining the lumped constant regionally to the fetal rat brain in utero. The lumped constant averaged 0.55 +- 0.15 relative to the maternal circulation. On this basis, we determined the glucose metabolic rate of the fetal rat brain to be one third of the corresponding maternal value, or 19 +- 2 {mu}mol hg{sup -1} min{sup -1}. (author).

  19. Ventromedial hypothalamic glucose sensing and glucose homeostasis vary throughout the estrous cycle.

    Science.gov (United States)

    Santiago, Ammy M; Clegg, Deborah J; Routh, Vanessa H

    2016-12-01

    17β-Estradiol (17βE) regulates glucose homeostasis in part by centrally mediated mechanisms. In female rodents, the influence of the ovarian cycle on hypoglycemia counterregulation and glucose tolerance is unclear. We found previously that in prepubertal females, 17βE modulates glucose sensing in nonadapting glucose-inhibited (GI) and adapting GI (AdGI) neurons within the ventrolateral portion of the ventromedial nucleus (VL-VMN). Nonadapting GI neurons persistently decrease their activity as glucose increases while AdGI neurons transiently respond to a glucose increase. To begin to understand if endogenous fluctuations in estrogen levels across the estrous cycle impact hypothalamic glucose sensing and glucose homeostasis, we assessed whether hypoglycemia counterregulation and glucose tolerance differed across the phases of the estrous cycle. We hypothesized that the response to insulin-induced hypoglycemia (IIH) and/or glucose tolerance would vary throughout the estrous cycle according to changes in 17βE availability. Moreover, that these changes would correlate with estrous-dependent changes in the glucose sensitivity of VL-VMN glucose-sensing neurons (GSNs). These hypotheses were tested in female mice by measuring the response to IIH, glucose tolerance and the glucose sensitivity of VL-VMN GSNs during each phase of the estrous cycle. Furthermore, a physiological brain concentration of 17βE seen during proestrus was acutely applied to brain slices isolated on the day of diestrous and the response to low glucose in VL-VMN GSNs was assayed. The response to IIH was strongest during diestrous. The response of nonadapting GI and AdGI neurons to a glucose decrease from 2.5 to 0.5mM also peaked during diestrous; an effect which was blunted by the addition of 17βE. In contrast, the glucose sensitivity of the subpopulation of GSNs which are excited by glucose (GE) was not affected by estrous phase or exogenous 17βE application. These data suggest that physiological

  20. Ventromedial hypothalamic glucose sensing and glucose homeostasis vary throughout the estrous cycle

    Science.gov (United States)

    Santiago, Ammy M.; Clegg, Deborah J.; Routh, Vanessa H.

    2016-01-01

    Objective 17β-Estradiol (17βE) regulates glucose homeostasis in part by centrally mediated mechanisms. In female rodents, the influence of the ovarian cycle on hypoglycemia counterregulation and glucose tolerance is unclear. We found previously that in prepubertal females, 17βE modulates glucose sensing in nonadapting glucose-inhibited (GI) and adapting GI (AdGI) neurons within the ventrolateral portion of the ventromedial nucleus (VL-VMN). Nonadapting GI neurons persistently decrease their activity as glucose increases while AdGI neurons transiently respond to a glucose increase. To begin to understand if endogenous fluctuations in estrogen levels across the estrous cycle impact hypothalamic glucose sensing and glucose homeostasis, we assessed whether hypoglycemia counterregulation and glucose tolerance differed across the phases of the estrous cycle. We hypothesized that the response to insulin-induced hypoglycemia (IIH) and/or glucose tolerance would vary throughout the estrous cycle according to changes in 17βE availability. Moreover, that these changes would correlate with estrous-dependent changes in the glucose sensitivity of VL-VMN glucose-sensing neurons (GSNs). Methods These hypotheses were tested in female mice by measuring the response to IIH, glucose tolerance and the glucose sensitivity of VL-VMN GSNs during each phase of the estrous cycle. Furthermore, a physiological brain concentration of 17βE seen during proestrus was acutely applied to brain slices isolated on the day of diestrous and the response to low glucose in VL-VMN GSNs was assayed. Results The response to IIH was strongest during diestrous. The response of nonadapting GI and AdGI neurons to a glucose decrease from 2.5 to 0.5mM also peaked during diestrous; an effect which was blunted by the addition of 17βE. In contrast, the glucose sensitivity of the subpopulation of GSNs which are excited by glucose (GE) was not affected by estrous phase or exogenous 17βE application. Conclusion

  1. Consumption of meat is associated with higher fasting glucose and insulin concentrations regardless of glucose and insulin genetic risk scores: a meta-analysis of 50,345 Caucasians

    Science.gov (United States)

    Recent studies suggest that meat intake is associated with diabetes-related phenotypes. However, whether the associations of meat intake and glucose and insulin homeostasis are modified by genes related to glucose and insulin is unknown. We investigated the associations of meat intake and the intera...

  2. Consumption of meat is associated with higher fasting glucose and insulin concentrations regardless of glucose and insulin genetic risk scores: A meta-analysis of 50,345 Caucasians

    NARCIS (Netherlands)

    A.M. Fretts (Amanda M.); J.L. Follis (Jack ); J.A. Nettleton (Jennifer ); R.N. Lemaitre (Rozenn ); J.S. Ngwa; M.K. Wojczynski (Mary ); I.-P. Kalafati (Ioanna-Panagiota); T.V. Varga (Tibor V.); A.C. Frazier-Wood (Alexis C.); D.K. Houston (Denise); J. Lahti (Jari); U. Ericson (Ulrika); E.H. van den Hooven (Edith); V. Mikkilä (Vera); J.C. Kiefte-de Jong (Jessica); D. Mozaffarian (Dariush); K.M. Rice (Kenneth); F. Renström (Frida); K.E. North (Kari); N.M. McKeown (Nicola ); M.F. Feitosa (Mary Furlan); S. Kanoni (Stavroula); C.E. Smith (Caren); M. Garcia (Melissa); A.-M. Tiainen (Anna-Maija); E. Sonestedt (Emily); A. Manichaikul (Ani); F.J.A. van Rooij (Frank); M. Dimitriou (Maria); O. Raitakari (Olli); J.S. Pankow (James); L. Djoussé (Luc); M.A. Province (Mike); F.B. Hu (Frank); C.-Q. Lai (Chao-Qiang); M.F. Keller (Margaux); M.-M. Perälä (Mia-Maria); J.I. Rotter (Jerome I.); A. Hofman (Albert); M.J. Graff (Maud J.L.); M. Kähönen (Mika); K. Mukamal (Kenneth); I. Johansson (Ingegerd); J.M. Ordovas (Jose); Y. Liu (YongMei); S. Männistö (Satu); A.G. Uitterlinden (André); P. Deloukas (Panagiotis); I. Seppälä (Ilkka); B.M. Psaty (Bruce); L.A. Cupples (Adrienne); I.B. Borecki (Ingrid); P.W. Franks (Paul W.); D.K. Arnett (Donna); M.A. Nalls (Michael); K. Hagen (Knut); M. Orho-Melander (Marju); O.H. Franco (Oscar); T. Lehtimäki (Terho); G.V. Dedoussis (George); J.B. Meigs (James); D.S. Siscovick (David)

    2015-01-01

    textabstractBackground: Recent studies suggest that meat intake is associated with diabetes-related phenotypes. However, whether the associations of meat intake and glucose and insulin homeostasis are modified by genes related to glucose and insulin is unknown. Objective: We investigated the

  3. Influence of Iatrogenic Gaps, Cement Type, and Time on Microleakage of Cast Posts Using Spectrophotometer and Glucose Filtration Measurements.

    Science.gov (United States)

    Al-Madi, Ebtissam M; Al-Saleh, Samar A; Al-Khudairy, Reem I; Aba-Hussein, Taibah W

    2018-04-06

    To determine the influence of iatrogenic gaps, type of cement, and time on microleakage of cast posts using spectrophotometer and glucose filtration measurements. Forty-eight single-rooted teeth were divided into eight groups of six teeth each. Teeth were instrumented and obturated, and a cast post was fabricated. In addition to two control groups (positive and negative), a total of six groups were prepared: In four groups, an artificial 2- to 3-mm gap was created between post and residual gutta percha (GP), and two groups were prepared with intimate contact between post and residual GP. Posts were cemented with either zinc phosphate cement or resin cement. Leakage through the post after 1, 8, 14, and 20 days was measured using a glucose penetration model with two different reading methods. Mixed analysis of variance tests were performed to analyze the data. The presence of a gap between the apical end of the post and the most coronal portion of the GP remaining in the root canal after post space preparation increased microleakage significantly. However, microleakage was significantly less when the gap was refilled with GP compared to no gap. There was no difference in leakage between luting cements used. It was concluded that none of the cements were able to prevent microleakage. However, the addition of GP to residual GP did increase the sealing ability.

  4. In-vivo measurements of regional acetylcholine esterase activity in degenerative dementia: comparison with blood flow and glucose metabolism.

    Science.gov (United States)

    Herholz, K; Bauer, B; Wienhard, K; Kracht, L; Mielke, R; Lenz, M O; Strotmann, T; Heiss, W D

    2000-01-01

    Memory and attention are cognitive functions that depend heavily on the cholinergic system. Local activity of acetylcholine esterase (AChE) is an indicator of its integrity. Using a recently developed tracer for positron emission tomography (PET), C-11-labeled N-methyl-4-piperidyl-acetate (C11-MP4A), we measured regional AChE activity in 4 non-demented subjects, 4 patients with dementia of Alzheimer type (DAT) and 1 patient with senile dementia of Lewy body type (SDLT), and compared the findings with measurements of blood flow (CBF) and glucose metabolism (CMRGlc). Initial tracer extraction was closely related to CBF. AChE activity was reduced significantly in all brain regions in demented subjects, whereas reduction of CMRGlc and CBF was more limited to temporo-parietal association areas. AChE activity in SDLT was in the lower range of values in DAT. Our results indicate that, compared to non-demented controls, there is a global reduction of cortical AChE activity in dementia. Dementia, cholinergic system, acetylcholine esterase, positron emission tomography, cerebral blood flow, cerebral glucose metabolism.

  5. Evaluation of three glucometers for whole blood glucose measurements at the point of care in preterm or low-birth-weight infants

    OpenAIRE

    Hwang, Joon Ho; Sohn, Yong-Hak; Chang, Seong-Sil; Kim, Seung Yeon

    2015-01-01

    Purpose We evaluated three blood glucose self-monitoring for measuring whole blood glucose levels in preterm and low-birth-weight infants. Methods Between December 1, 2012 and March 31, 2013, 230 blood samples were collected from 50 newborns, who weighed, ≤2,300 g or were ≤36 weeks old, in the the neonatal intensive care unit of Eulji University Hospital. Three blood glucose self-monitoring (A: Precision Pcx, Abbott; B: One-Touch Verio, Johnson & Johnson; C: LifeScan SureStep Flexx, Johnson &...

  6. 40 CFR 761.316 - Interpreting PCB concentration measurements resulting from this sampling scheme.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Interpreting PCB concentration