WorldWideScience

Sample records for gloves

  1. Removable glove for a glove box

    International Nuclear Information System (INIS)

    Lucas, J.M.

    1982-01-01

    The glove includes one part forming a cuff and another part forming the glove. These two parts are joined in a leak-tight manner by a rigid ring. The glove part is interchangeable without breaking the seal through two neighbouring grooves formed on the ring to receive a bead made on the open end of the glove. The grooves are visible when the glove is placed outside the glove box, thereby enabling the glove part to be changed in this position [fr

  2. Gloves, extra gloves or special types of gloves for preventing percutaneous exposure injuries in healthcare personnel.

    Science.gov (United States)

    Mischke, Christina; Verbeek, Jos H; Saarto, Annika; Lavoie, Marie-Claude; Pahwa, Manisha; Ijaz, Sharea

    2014-03-07

    Healthcare workers are at risk of acquiring viral diseases such as hepatitis B, hepatitis C and HIV through exposure to contaminated blood and body fluids at work. Most often infection occurs when a healthcare worker inadvertently punctures the skin of their hand with a sharp implement that has been used in the treatment of an infected patient, thus bringing the patient's blood into contact with their own. Such occurrences are commonly known as percutaneous exposure incidents. To determine the benefits and harms of extra gloves for preventing percutaneous exposure incidents among healthcare workers versus no intervention or alternative interventions. We searched CENTRAL, MEDLINE, EMBASE, NHSEED, Science Citation Index Expanded, CINAHL, NIOSHTIC, CISDOC, PsycINFO and LILACS until 26 June 2013. Randomised controlled trials (RCTs) with healthcare workers as the majority of participants, extra gloves or special types of gloves as the intervention, and exposure to blood or bodily fluids as the outcome. Two authors independently assessed study eligibility and risk of bias, and extracted data. We performed meta-analyses for seven different comparisons. We found 34 RCTs that included 6890 person-operations as participating units and reported on 46 intervention-control group comparisons. We grouped interventions as follows: increased layers of standard gloves, gloves manufactured with special protective materials or thicker gloves, and gloves with puncture indicator systems. Indicator gloves show a coloured spot when they are perforated. Participants were surgeons in all studies and they used at least one pair of standard gloves as the control intervention. Twenty-seven studies also included other surgical staff (e.g. nurses). All but one study used perforations in gloves as an indication of exposure. The median control group rate was 18.5 perforations per 100 person-operations. Seven studies reported blood stains on the skin and two studies reported self reported

  3. Glove Use and Glove Education in Workers with Hand Dermatitis.

    Science.gov (United States)

    Rowley, Kyle; Ajami, Daana; Gervais, Denise; Mooney, Lindsay; Belote, Amy; Kudla, Irena; Switzer-McIntyre, Sharon; Holness, D Linn

    2016-01-01

    Occupational skin diseases are common. The occurrence of occupational skin diseases represents a failure of primary prevention strategies that may include the use of personal protective equipment, most commonly gloves. The objective of this study was to describe current glove use and education practices related to gloves in workers being assessed for possible work-related hand dermatitis. Participants included consecutive patients being assessed for possible work-related hand dermatitis. A self-administered questionnaire obtained information on demographics, workplace characteristics and exposures, glove use, and education regarding gloves. Ninety percent of the 105 participants reported using gloves. Only 44% had received training related to glove use in the workplace. Major gaps in training content included skin care when using gloves, warning signs of skin problems, and glove size. If the worker indicated no glove training received, the majority reported they would have used gloves if such training was provided. Although the majority of workers being assessed wore gloves, the minority had received training related to glove use. Particular gaps in training content were identified. Those who had not received training noted they would likely have used gloves if training had been provided.

  4. Glove perforation rate with orthopedic gloving versus double gloving technique in tibial plateau leveling osteotomy: A randomized trial

    Science.gov (United States)

    Egeler, Kimberly; Stephenson, Nicole; Stanke, Natasha

    2016-01-01

    In this randomized, prospective study, perforation rates, glove change rates, and cost between orthopedic gloves (n = 227) and double gloving with standard latex surgical gloves (n = 178) worn in tibial plateau leveling osteotomy procedures were compared. Gloves were collected from the surgeon and surgical resident after procedures and were tested for perforations with a standardized water leak test, as described by the American Society for Testing and Materials International. No statistically significant difference was found between the perforation rate using orthopedic gloving and double gloving techniques (P = 0.629) or the rate at which gloves were changed (P = 0.146). Orthopedic gloving was 2.1 times more costly than double gloving but they may be preferred by surgeons for dexterity and comfort. PMID:27807378

  5. Latex medical gloves

    DEFF Research Database (Denmark)

    Palosuo, Timo; Antoniadou, Irini; Gottrup, Finn

    2011-01-01

    Many hospitals have implemented policies to restrict or ban the use of devices made of natural rubber latex (NRL) in healthcare as precautionary measures against the perceived risk of NRL allergy. Changes in glove technology, progress in measuring the specific allergenic potential of gloves...... properties of NRL and synthetic gloves and the role of glove powder. The review shows that NRL medical gloves, when compared with synthetic gloves, tend to be stronger, more flexible and better accepted by clinicians. The introduction of powder-free gloves has been associated with reductions in protein...

  6. Contaminated glove remover for rubber or synthetic gloves

    International Nuclear Information System (INIS)

    Counit, G.; Charvolin, M.

    1993-01-01

    The glove remover, especially for protective rubber or synthetic gloves used to handle toxic materials in the nuclear, chemical and other industries, consist of a housing with a chamber into which the gloved hand is inserted, an outer depression chamber and a perforated wall between the two. A vacuum unit creates a low pressure inside the chamber enabling the hand to be withdrawn from the glove, which is then drawn through the pipe into a container for disposal. The open end of the chamber is covered by a diaphragm which surrounds and seals the arm which is inserted into it with the gloved hand. The diaphragm can occupy three positions: closed, where it surrounds and seals the arm; open, allowing the hand to be inserted or withdrawn, and intermediate, when air can pass from the outside between the hand and glove. A similar chamber is used for removing boots

  7. Comprehension Strategy Gloves.

    Science.gov (United States)

    Newman, Gayle

    2002-01-01

    Describes the idea of creating a glove for each of the comprehension strategies for use with different text structures. Notes that the gloves serve as a multisensory approach by providing visual clues through icons on each finger and the palm. Discusses three different gloves: the prereading glove, the narrative text structure glove, and the…

  8. Is double-gloving really protective? A comparison between the glove perforation rate among perioperative nurses with single and double gloves during surgery.

    Science.gov (United States)

    Guo, Yue Ping; Wong, Po Ming; Li, Yi; Or, Peggy Pui Lai

    2012-08-01

    Surgical teams rely on surgical gloves as a barrier to protect themselves against blood-borne pathogenic infections during surgery. Double-gloving is adopted by surgeons to tackle the problem of glove perforation. Nevertheless, double-gloving is not practiced commonly by operating room nurses and there are only limited studies about double-gloving that targets only perioperative nurses. The aim of this research was to assess the effectiveness of double-gloving in protecting perioperative nurses by comparing the frequency of glove perforation between single-gloving and double-gloving groups. A prospective and randomized study was performed. Nurses were assigned randomly to single-gloved and double-gloved groups for comparison of the glove perforation rate. Water-leakage and air-inflation tests were used to detect glove perforation. Glove perforations was detected in 10 of 112 sets of single-gloves (8.9%) and 12 of 106 sets of outer gloves in the double-gloved group (11.3%). There was no inner double-glove perforation (0%). Glove perforations were found in 6 and 4 of the 112 sets of single-gloves for the first assistants (5.36%) and the scrub nurses (3.57%), and 5 and 7 of 106 sets of outer gloves in the double-gloved group for the first assistants (4.72%) and the scrub nurses (6.60%), respectively. The average occurrence of perforation was 69.8 minutes (range, 20-110 min) after the beginning of surgery. The sites of perforation were localized mostly on the left middle finger (42%) and the left ring finger (33.3%). Based on the findings of the study, double-gloving is indeed effective in protecting operating room nurses against blood-borne pathogen exposure. It should be introduced as a routine practice. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Glove 101

    Science.gov (United States)

    Ross, Amy

    2008-01-01

    This presentation addressed the question "What is a spacesuit glove?" - a highly specialized mobility system. It is an excellent basic tutorial on the design considerations of a spacesuit glove and the many facets of developing a glove that provides good mobility and thermal protection.

  10. Rubber glove wearing device

    International Nuclear Information System (INIS)

    Nozaki, Tatsuo; Takada, Kaoru.

    1994-01-01

    Rubber groves are attached each to an upper end of a glove putting vessel having an air-sucking hole on the bottom by enlarging an opening end of the rubber glove and turning back the inside to the outside. When the sucking device is operated, air in the glove putting device is sucked and the rubber glove is expanded by an atmospheric pressure. After expansion of the rubber glove to some extent, the sucking device is stopped, and presence or absence of failures of the rubber glove is confirmed by shrinkage of the rubber glove and by an indication value of a pressure gauge for detecting the pressure change in the vessel. Then, a hand is inserted to the expanded rubber glove, and a detaching switch in the vessel is pushed by a finger tip. A detaching piece at the upper end of the vessel is protruded outwardly to enlarge the turned-back portion of the rubber glove to easily release the rubber glove from the putting vessel, and the rubber glove is put on. This enables to wear the rubber glove and conduct failure test simultaneously. Further, a user can put on the rubber glove without touching the outside of the rubber glove. (I.N.)

  11. Glove material, reservoir formation, and dose affect glove permeation and subsequent skin penetration.

    Science.gov (United States)

    Nielsen, Jesper Bo; Sørensen, Jens Ahm

    2012-02-15

    Protective gloves are used to reduce dermal exposure when managing chemical exposures at the work place. Different glove materials may offer different degrees of protection. The present study combined the traditional ASTM (American Society for Testing and Materials) model with the Franz diffusion cell to evaluate overall penetration through glove and skin as well as the deposition in the different reservoirs. Benzoic acid was applied on latex or nitrile gloves placed on top of human skin. The amounts of chemical were quantified in the glove material, between glove and skin, within the skin, and in the receptor chamber. Both glove materials reduce total penetration of benzoic acid, but nitrile gloves offer a significantly better protection than latex gloves. This difference was less pronounced at the higher of the two concentrations of benzoic acid applied. Thus, glove types that offer relevant protection at low concentrations does not necessarily give appropriate protection at high concentrations. Significant amounts of benzoic acid could be extracted from the glove materials after exposure. If a chemical is accumulated in the glove material, reuse of single-use gloves should be cautioned. The reuse of gloves is generally not to be recommended without effective decontamination. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. Touch sensitivity with sterile standard surgical gloves and single-use protective gloves.

    Science.gov (United States)

    Tiefenthaler, W; Gimpl, S; Wechselberger, G; Benzer, A

    2006-10-01

    The purpose of this study was to evaluate touch sensitivity and static two-point discrimination of the dominant index and middle finger in 20 anaesthetists wearing no gloves, single-use protective gloves or sterile standard surgical gloves. Semmes-Weinstein filaments were used to measure cutaneous pressure thresholds, and a Two-Point-Discriminator to estimate static two-point discrimination. Wearing gloves significantly reduced touch sensitivity (p gloves. The results of our study suggest that the additional cost of sterile standard surgical gloves can not be justified in terms of touch sensitivity.

  13. RoboGlove: Initial Work Toward a Robotically Assisted EVA Glove

    Science.gov (United States)

    Rogers, Jonathan

    2015-01-01

    The RoboGlove is a device designed to provide additional grip strength or endurance for a user. In applying this Robonaut 2 spinoff technology to the Phase VI Space Suit glove, the project is using robotic tendons and actuators to regain some of the hand performance that is lost when wearing a pressurized glove. An array of sensors embedded into the finger softgoods provides input to the control system which retracts the tendons, helping to close the user's hand. While active, this system provides augmentation, but is nonintrusive to glove usage when disabled.

  14. Anti-vibration gloves?

    Science.gov (United States)

    Hewitt, Sue; Dong, Ren G; Welcome, Daniel E; McDowell, Thomas W

    2015-03-01

    For exposure to hand-transmitted vibration (HTV), personal protective equipment is sold in the form of anti-vibration (AV) gloves, but it remains unclear how much these gloves actually reduce vibration exposure or prevent the development of hand-arm vibration syndrome in the workplace. This commentary describes some of the issues that surround the classification of AV gloves, the assessment of their effectiveness and their applicability in the workplace. The available information shows that AV gloves are unreliable as devices for controlling HTV exposures. Other means of vibration control, such as using alternative production techniques, low-vibration machinery, routine preventative maintenance regimes, and controlling exposure durations are far more likely to deliver effective vibration reductions and should be implemented. Furthermore, AV gloves may introduce some adverse effects such as increasing grip force and reducing manual dexterity. Therefore, one should balance the benefits of AV gloves and their potential adverse effects if their use is considered. © Crown copyright 2014.

  15. Development of a new glove for glove boxes with high level performances

    International Nuclear Information System (INIS)

    Jerome Blancher; Jean-Marc Poirier

    2006-01-01

    This paper describes the results of a joint technological program of COGEMA and MAPA to develop a new generation of glove for glove boxes. The mechanical strength of this glove is twice as high as the best characteristics of gloves available on the market. This new generation of product has both a higher level of performance and better ergonomics. (authors)

  16. Development of a new glove for glove boxes with high level performances

    Energy Technology Data Exchange (ETDEWEB)

    Jerome Blancher [AREVA/COGEMA Recycling Business Unit, BP 94176 - 30204 Bagnols-sur-Ceze Cedex (France); Jean-Marc Poirier [MAPA SPONTEX, BP 190 - 92205 Neuilly sur Seine Cedex (France)

    2006-07-01

    This paper describes the results of a joint technological program of COGEMA and MAPA to develop a new generation of glove for glove boxes. The mechanical strength of this glove is twice as high as the best characteristics of gloves available on the market. This new generation of product has both a higher level of performance and better ergonomics. (authors)

  17. 76 FR 28308 - Compliance Policy Guide: Surgeons' Gloves and Patient Examination Gloves; Defects-Criteria for...

    Science.gov (United States)

    2011-05-17

    .... FDA-2011-D-0258] Compliance Policy Guide: Surgeons' Gloves and Patient Examination Gloves; Defects... Compliance Policy Guide Sec. 335.700, Surgeons' Gloves and Patient Examination Gloves; Defects--Criteria for... FDA staff on the submission of seizure recommendations for medical gloves that exceed the defect...

  18. Delayed reactions to reusable protective gloves.

    Science.gov (United States)

    Pontén, Ann; Dubnika, Inese

    2009-04-01

    The materials in plastic protective gloves are thought to cause less contact allergy than rubber gloves. Our aim was to estimate the frequency of delayed reactions to different types of reusable protective gloves among dermatitis patients. 2 x 2 cm pieces of polyvinyl chloride (PVC) gloves, nitrile gloves, and natural rubber latex (NRL) gloves were tested as is in consecutive dermatitis patients tested with the baseline series. Among 658 patients, 6 patients reacted to PVC gloves and 6 patients to the NRL gloves. None reacted to both these types of gloves. Five of six patients with reactions to rubber gloves reacted to thiuram mix in the baseline series. Delayed reactions to reusable PVC gloves may be as common as to reusable NRL gloves. In contrast to most reactions to the NRL glove, the reactions to the PVC glove had no obvious association with reactions to any allergen(s) in the baseline series.

  19. Influence of orthopedic reinforced gloves versus double standard gloves on contamination events during small animal orthopedic surgery.

    Science.gov (United States)

    Hayes, Galina; Singh, Ameet; Gibson, Tom; Moens, Noel; Oblak, Michelle; Ogilvie, Adam; Reynolds, Debbie

    2017-10-01

    To determine the influence of orthopedic reinforced gloves on contamination events during small animal orthopedic surgery. Prospective randomized controlled trial SAMPLE POPULATION: Two hundred and thirty-seven pairs of orthopedic gloves (474 gloves) and 203 pairs of double standard gloves (812 gloves) worn during 193 orthopedic procedures. Primary and assistant surgeons were randomized to wear either orthopedic reinforced gloves or double gloves. Gloves were leak tested to identify perforations at the end of procedures. Perforations detected intraoperatively or postoperatively were recorded. A contamination event was defined as at least one perforation on either hand for orthopedic reinforced gloves, or a perforation of both the inner and outer glove on the same hand for double gloves. Baseline characteristics between the 2 intervention groups were similar. There was no difference in contamination events between the double-gloved and orthopedic gloved groups (OR = 0.95, 95% CI = 0.49-1.87, P = .89). The same percentage of contamination events (8% glove pairs used) occurred in the double gloved group (17 contamination events) and in the orthopedic gloved group (19 contamination events). The odds of a contamination event increased by 1.02 (95% CI 1.01-1.03, P contamination events in small animal orthopedic procedures. Surgeons reluctant to double glove due to perceptions of decreased dexterity and discomfort may safely opt for wearing orthopedic gloves, which may improve their compliance. © 2017 The American College of Veterinary Surgeons.

  20. Radio opaque gloves

    International Nuclear Information System (INIS)

    Whittaker, A.V.; Whittaker, R.E. Jr.; Goldstrom, R.A.; Shipko, F.J.

    1975-01-01

    Radiation shielding garments and accessories, such as radio-opaque gloves for surgeons, shielding against the harmful x-ray radiation in a fluoroscopic zone, are advantageously different from garments for shielding from other medical uses of x-rays. Such garments are provided with zones of differing opacity, whereby desired sensitivity and ''feel'' through the glove material is retained. One feature is the provision of an ''opacity gradient'' across the glove cross section with opacity being relatively low at the fingertip area (lesser shield-thickness), but relatively high at the less nonprehensile hand zones, such as the palm. Glove fabrication techniques for achieving such an opacity gradient are described. (U.S.)

  1. Double gloving to reduce surgical cross-infection.

    Science.gov (United States)

    Tanner, J; Parkinson, H

    2006-07-19

    The invasive nature of surgery, with its increased exposure to blood, means that during surgery there is a high risk of transfer of pathogens. Pathogens can be transferred through contact between surgical patients and the surgical team, resulting in post-operative or blood borne infections in patients or blood borne infections in the surgical team. Both patients and the surgical team need to be protected from this risk. This risk can be reduced by implementing protective barriers such as wearing surgical gloves. Wearing two pairs of surgical gloves, triple gloves, glove liners or cloth outer gloves, as opposed to one pair, is considered to provide an additional barrier and further reduce the risk of contamination. The primary objective of this review was to determine if additional glove protection reduces the number of surgical site or blood borne infections in patients or the surgical team. The secondary objective was to determine if additional glove protection reduces the number of perforations to the innermost pair of surgical gloves. The innermost gloves (next to skin) compared with the outermost gloves are considered to be the last barrier between the patient and the surgical team. We searched the Cochrane Wounds Group Specialised Register (January 2006), and the Cochrane Central Register of Controlled Trials (CENTRAL)(The Cochrane Library Issue 4, 2005). We also contacted glove manufacturing companies and professional organisations. Randomised controlled trials involving: single gloving, double gloving, triple gloving, glove liners, knitted outer gloves, steel weave outer gloves and perforation indicator systems. Both authors independently assessed the relevance and quality of each trial. Data was extracted by one author and cross checked for accuracy by the second author. Two trials were found which addressed the primary outcome, namely, surgical site infections in patients. Both trials reported no infections. Thirty one randomised controlled trials

  2. Formaldehyde in reusable protective gloves.

    Science.gov (United States)

    Pontén, Ann

    2006-05-01

    Due to the clinical findings in a single patient's case, formaldehyde was suspected to be present in clinically relevant levels in reusable protective gloves. Therefore, 9 types of gloves were investigated with the semi-quantitative chromotropic acid method. It was found that 6/9 gloves emitted some formaldehyde and that 4/9 gloves emitted > or =40 microg of formaldehyde. Most of the formaldehyde was found on the inside of the gloves. To get an indication of the clinical relevance, a comparison with a protective cream declared to contain the formaldehyde-releasing agent diazolidinyl urea was performed by comparing areas of gloves with areas of cream layers with thickness 1-2 mg/cm(2). It was found that the amounts of formaldehyde emitted from the gloves might be in the same range as emitted from a layer of cream.

  3. FY13 High Performance EVA Glove (HPEG) Collaboration: Glove Injury Data Mining Effort - Training Data Overview

    Science.gov (United States)

    Reid, Christopher; Benson, Elizabeth; England, Scott; Charvat, Jacqueline; Norcross, Jason; McFarland, Shane; Rajulu, Sudhakar

    2014-01-01

    From the time hand-intensive tasks were first created for EVAs, discomforts and injuries have been noted.. There have been numerous versions of EVA gloves for US crew over the past 50 years, yet pain and injuries persist. The investigation team was tasked with assisting in a glove injury assessment for the High Performance EVA Glove (HPEG) project.center dot To aid in this assessment, the team was asked to complete the following objectives: - First, to develop the best current understanding of what glove-related injuries have occurred to date, and when possible, identify the specific mechanisms that caused those injuries - Second, to create a standardized method for comparison of glove injury potential from one glove to another. center dot The overall goal of the gloved hand injury assessment is to utilize ergonomics in understanding how these glove injuries are occurring, and to propose mitigations to current designs or design changes in the next generation of EVA gloves.

  4. Glove box

    International Nuclear Information System (INIS)

    Morita, Atsushi

    1990-01-01

    Wire rope earthquake proof supports having sufficient vibration transmitting and attenuating property are disposed between a fixed floor and the bottom of a glove box in order to improve earthquake proofness of the glove box. The vertical weight of the glove box is supported by support legs slidable on the surface of the fixed floor. The wire rope earthquake-proof supports when undergoing a load, cause stretching and rolling against the external force such as earthquakes, and provide flexible spring support and cause a great damping due to friction with strands. Further, the vertical weight is always supported by the support legs and, when a horizontal weight is applied, the glove box slides on the fixed floor freely with slidable members. In this way, stress concentration generated at joint portions of columns and beams can be moderated greatly and earthquake proofness can be improved. Further, quality control and maintenance for the device is almost unnecessary owing to excellent fatigue-resistant characteristics of the wire rope earthquake proof supports. (N.H.)

  5. Glove boxes

    International Nuclear Information System (INIS)

    Eisert, G.A.

    1979-01-01

    An arrangement for effecting access for performing work within a glove box comprises an elongate arm-length impermeable flexible sleeve, a fitting having an aperture therethrough, adapted to be secured in sealing relation in a port, in a wall of the glove box, the fitting including an outwardly extending lip having at least one continuous groove extending around its outer periphery, one end of the sleeve extending through the aperture in fitting and being folded back against the outer periphery of the lip, a resilient fastening ring securing the sleeve in sealing engagement in the groove, clamping means securing the sleeves to the lip and a glove secured in sealing relation via a bushing to the other end of the sleeve. (author)

  6. Effects of Frequent Glove Change on Outcomes of Orthopaedic Surgical Procedures - A Multicenter Study on Surgical Gloves

    Directory of Open Access Journals (Sweden)

    Nishit Palo

    2017-10-01

    Full Text Available Introduction: Intact surgical gloves are a barrier to microorganisms migration between surgical team members and the patient. The surgical gloves are changed at various junctures but the effects of changing gloves during surgical procedures on various surgical parameters or clinical outcomes are not established. Aim: To determine rationale of glove change during orthopaedic procedures, differences amongst surgical parameters with and without changing the surgical gloves and whether frequent glove change affected surgical parameters or clinical outcomes. Materials and Methods: A prospective multicenter study conducted at three centers from January 2014 to January 2016. A 250 patients were divided into 2 groups (n=125 each in Group 1, surgical team operated with regular changing of gloves. In Group 2, only 1 set of double gloves were worn throughout the procedure. Surgical parameters or clinical outcomes were assessed for both the groups. Statistical analyses included the median, mode, range, Interquartile Range (IQR and sample standard deviation (s and independent-samples t-test. Bacterial counts were expressed as median with (IQR. Results: Surgical Timing Difference was 10 (S.D.- 4.2 minutes more in Group-1 (<0.05, Surgical Cost was higher in Group-1 by Rs.150-450 (<0.05. Outer glove micro-perforation rate was 5.85% and 8.15% in group-1 and 2 respectively with no inner glove perforation or Surgical Site Infections. Outer glove micro perforations were proportional to duration of surgery; operations lasting 120-210 and 61-120 minutes had 66.6% and 37.2% micro perforation rates respectively (p<0.05. Conclusion: Under standard operating conditions, procedures performed without glove change are shorter and cost effective than procedures performed with regular glove change with similar surgical and functional results. Judicious use of surgical gloves is a patient and environment friendly option, thereby reducing the hospital’s biomedical waste load.

  7. Nitrile versus Latex for Glove Juice Sampling.

    Science.gov (United States)

    Landers, Timothy F; Dent, Anthony

    2014-01-01

    The objective of this study was to explore the utility of nitrile gloves as a replacement for latex surgical gloves in recovering bacteria from the hands. Two types of nitrile gloves were compared to latex gloves using the parallel streak method. Streaks of Klebsiella pneumoniae and Staphylococcus aureus were made on tryptic soy agar plates, and the zones of inhibition were measured around pieces of glove material placed on the plates. Latex gloves produced a mean zone of inhibition of 0.28 mm, compared to 0.002 mm for nitrile gloves (pnitrile may be a viable alternative to latex in glove juice sampling methods, since nitrile avoids the risk of latex exposure.

  8. Installation equipment for a glove box

    International Nuclear Information System (INIS)

    Loriot, P.

    1993-01-01

    The equipment uses a hollow support on which the glove to be replaced is mounted. It carries two grooves to ensure that the edges of the new and used glove are securely held in position. The new glove is temporarily fitted to a mounting ring using a mounting jig which stretches the edge of the new glove around its rim. The mounting ring is then positioned over the hollow support and the edge of the glove transferred onto it. (author)

  9. Gloves Reprocessing: Does It Really Save Money?

    Science.gov (United States)

    Arora, Pankaj; Kumari, Santosh; Sodhi, Jitender; Talati, Shweta; Gupta, Anil Kumar

    2015-12-01

    Gloves are reprocessed and reused in health-care facilities in resource-limited settings to reduce the cost of availability of gloves. The study was done with the aim to compute the cost of reprocessing of gloves so that an economically rationale decision can be taken. A retrospective record-based cross-sectional study was undertaken in a central sterile supply department where different steps during reprocessing of gloves were identified and the cost involved in reprocessing per pair of gloves was calculated. The cost of material and manpower was calculated to arrive at the cost of reprocessing per pair of gloves. The cost of a reprocessed pair of surgical gloves was calculated to be Indian Rupee (INR) 14.33 which was greater than the cost of a new pair of disposable surgical gloves (INR 9.90) as the cost of sterilization of one pair of gloves itself came out to  be INR 10.97. The current study showed that the purchase of sterile disposable single-use gloves is cheaper than the process of recycling. Reprocessing of gloves is not economical on tangible terms even in resource-limited settings, and from the perspective of better infection control as well as health-care worker safety, it further justifies the use of disposable gloves.

  10. EVA Glove Sensor Feasbility II Abstract

    Science.gov (United States)

    Melone, Kate

    2014-01-01

    The main objectives for the glove project include taking various measurements from human subjects during and after they perform different tasks in the glove box, acquiring data from these tests and determining the accuracy of these results, interpreting and analyzing this data, and using the data to better understand how hand injuries are caused during EVAs.1 Some of these measurements include force readings, temperature readings, and micro-circulatory blood flow.1 The three glove conditions tested were ungloved (a comfort glove was worn to house the sensors), Series 4000, and Phase VI. The general approach/procedure for the glove sensor feasibility project is as follows: 1. Prepare test subject for testing. This includes attaching numerous sensors (approximately 50) to the test subject, wiring, and weaving the sensors and wires in the glove which helps to keep everything together. This also includes recording baseline moisture data using the Vapometer and MoistSense. 2. Pressurizing the glove box. Once the glove box is pressurized to the desired pressure (4.3 psid), testing can begin. 3. Testing. The test subject will perform a series of tests, some of which include pinching a load cell, making a fist, pushing down on a force plate, and picking up metal pegs, rotating them 90 degrees, and placing them back in the peg board. 4. Post glove box testing data collection. After the data is collected from inside the glove box, the Vapometer and MoistSense device will be used to collect moisture data from the subject's hand. 5. Survey. At the conclusion of testing, he/she will complete a survey that asks questions pertaining to comfort/discomfort levels of the glove, glove sizing, as well as offering any additional feedback.

  11. Development of rubber gloves by radiation vulcanization

    International Nuclear Information System (INIS)

    Makuuchi, K.; Yoshii, F.; Ishigaki, I.; Mogi, M.; Saito, T.

    1990-01-01

    The processes of radiation vulcanization and production of protective rubber gloves for radioactive contamination are described. A newly developed sensitizing system consisting of 5 phr 2-ethylhexyl acrylate and 1 phr carbon tetrachloride was used to vulcanize natural rubber latex at 12 kGy. Transparent and soft gloves were obtained from the radiation vulcanized latex by a coagulant dipping process. The mechanical properties of the gloves meet Japanese Industrial Standard specification for protective gloves. Combustion analysis of the gloves revealed that the amount of evolved sulfur dioxide and remaining ashes are less than those from commercially available rubber gloves. A trial usage of the gloves at a nuclear power plant showed that the gloves were easy to use for delicate work without undergoing fatigue. (author)

  12. Do clinical examination gloves provide adequate electrical insulation for safe hands-on defibrillation? I: Resistive properties of nitrile gloves.

    Science.gov (United States)

    Deakin, Charles D; Lee-Shrewsbury, Victoria; Hogg, Kitwani; Petley, Graham W

    2013-07-01

    Uninterrupted chest compressions are a key factor in determining resuscitation success. Interruptions to chest compression are often associated with defibrillation, particularly the need to stand clear from the patient during defibrillation. It has been suggested that clinical examination gloves may provide adequate electrical resistance to enable safe hands-on defibrillation in order to minimise interruptions. We therefore examined whether commonly used nitrile clinical examination gloves provide adequate resistance to current flow to enable safe hands-on defibrillation. Clinical examination gloves (Kimberly Clark KC300 Sterling nitrile) worn by members of hospital cardiac arrest teams were collected immediately following termination of resuscitation. To determine the level of protection afforded by visually intact gloves, electrical resistance across the glove was measured by applying a DC voltage across the glove and measuring subsequent resistance. Forty new unused gloves (control) were compared with 28 clinical (non-CPR) gloves and 128 clinical (CPR) gloves. One glove in each group had a visible tear and was excluded from analysis. Control gloves had a minimum resistance of 120 kΩ (median 190 kΩ) compared with 60 kΩ in clinical gloves (both CPR (median 140 kΩ) and non-CPR groups (median 160 kΩ)). Nitrile clinical examination gloves do not provide adequate electrical insulation for the rescuer to safely undertake 'hands-on' defibrillation and when exposed to the physical forces of external chest compression, even greater resistive degradation occurs. Further work is required to identify gloves suitable for safe use for 'hands-on' defibrillation. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  13. Knitted outer gloves in primary hip and knee arthroplasty.

    Science.gov (United States)

    Tanner, J; Wraighte, P; Howard, P

    2006-01-01

    A randomised trial was carried out to determine the rate of perforation to inner gloves when comparing latex with knitted gloves during hip and knee arthroplasty. Members of the surgical team were randomised to wear either two pairs of latex gloves (standard double gloving) or a knitted glove on top of a latex glove. In addition, participants completed a visual analogue assessment of their overall satisfaction with the gloves. A total of 406 inner gloves were tested for perforations over a four-month period: 23% of inner gloves were perforated when latex outer gloves were used and 6% of inner gloves were perforated when knitted outer gloves were used. In total, there were 64 perforations to the inner gloves; only one of these perforations was detected by the glove wearer. Wearing knitted outer gloves during hip and knee arthroplasty statistically significantly reduces the risk of perforation to inner latex gloves (p<0.0001).

  14. Whole glove permeation of cyclohexanol through disposable nitrile gloves on a dextrous robot hand: Fist clenching vs. non-clenching.

    Science.gov (United States)

    Mathews, Airek R; Que Hee, Shane S

    2017-04-01

    The differences in permeation parameters when a gloved dextrous robot hand clenched and did not were investigated with the dynamic permeation system described in the companion paper. Increased permeation through the gloves of the present study for cyclohexanol when the gloved hand clenched depended on glove thickness and porosity for cyclohexanol permeation. The Sterling glove, the thinnest and most porous, was the least protective. Hand clenching promoted more permeation for the Sterling glove in terms of breakthrough times, steady state permeation rate, and diffusion coefficient. The Safeskin glove showed increased permeation only for the steady state permeation rate but not breakthrough times or diffusion coefficient. The Blue and Purple gloves showed no differences when the hand was clenching or not. The correlational analysis supported differences between the clenching and non-clenching situations, and the risk assessment considered the worst and best scenarios relative to one and two hydrated hands that were and were not protected by specific gloves.

  15. Nitrile versus Latex for Glove Juice Sampling.

    Directory of Open Access Journals (Sweden)

    Timothy F Landers

    Full Text Available The objective of this study was to explore the utility of nitrile gloves as a replacement for latex surgical gloves in recovering bacteria from the hands. Two types of nitrile gloves were compared to latex gloves using the parallel streak method. Streaks of Klebsiella pneumoniae and Staphylococcus aureus were made on tryptic soy agar plates, and the zones of inhibition were measured around pieces of glove material placed on the plates. Latex gloves produced a mean zone of inhibition of 0.28 mm, compared to 0.002 mm for nitrile gloves (p<.001. While the parallel streak method is not intended as a quantitative estimate of antimicrobial properties, these results suggest that nitrile may be a viable alternative to latex in glove juice sampling methods, since nitrile avoids the risk of latex exposure.

  16. Evaluation of an antimicrobial surgical glove to inactivate live human immunodeficiency virus following simulated glove puncture.

    Science.gov (United States)

    Edmiston, Charles E; Zhou, S Steve; Hoerner, Pierre; Krikorian, Raffi; Krepel, Candace J; Lewis, Brian D; Brown, Kellie R; Rossi, Peter J; Graham, Mary Beth; Seabrook, Gary R

    2013-02-01

    Percutaneous injuries associated with cutting instruments, needles, and other sharps (eg, metallic meshes, bone fragments, etc) occur commonly during surgical procedures, exposing members of surgical teams to the risk for contamination by blood-borne pathogens. This study evaluated the efficacy of an innovative integrated antimicrobial glove to reduce transmission of the human immunodeficiency virus (HIV) following a simulated surgical-glove puncture injury. A pneumatically activated puncturing apparatus was used in a surgical-glove perforation model to evaluate the passage of live HIV-1 virus transferred via a contaminated blood-laden needle, using a reference (standard double-layer glove) and an antimicrobial benzalkonium chloride (BKC) surgical glove. The study used 2 experimental designs. In method A, 10 replicates were used in 2 cycles to compare the mean viral load following passage through standard and antimicrobial gloves. In method B, 10 replicates were pooled into 3 aliquots and were used to assess viral passage though standard and antimicrobial test gloves. In both methods, viral viability was assessed by observing the cytopathic effects in human lymphocytic C8166 T-cell tissue culture. Concurrent viral and cell culture viability controls were run in parallel with the experiment's studies. All controls involving tissue culture and viral viability were performed according to study design. Mean HIV viral loads (log(10)TCID(50)) were significantly reduced (P reduction (log reduction and percent viral reduction) of the HIV virus ranged from 1.96 to 2.4 and from 98.9% to 99.6%, respectively, following simulated surgical-glove perforation. Sharps injuries in the operating room pose a significant occupational risk for surgical practitioners. The findings of this study suggest that an innovative antimicrobial glove was effective at significantly (P < .01) reducing the risk for blood-borne virus transfer in a model of simulated glove perforation. Copyright

  17. The mechanical and microbiological integrity of surgical gloves.

    Science.gov (United States)

    Jamal, Ala; Wilkinson, Stephen

    2003-03-01

    Several manufacturers supply surgical gloves that have been individually tested (IT) for leaks. Other manufacturers supply gloves in which sample gloves from each batch are tested for leaks (batch tested: BT). The latter brands may be rejected by surgeons because of presumed increased risk of wound infection and staff exposure to patient pathogens. The influence of differences between glove brands on performance in surgery has not been extensively studied. The aims of the present study were to test the mechanical and microbiological integrity of IT compared to BT gloves. A total of 110 unused gloves from each of an IT and a BT brand were tested for leaks, first, by observation of water-jets from water-filled gloves and second, by measuring electrical resistance between inside and outside the glove surfaces, to give a baseline measure. A total of 304 IT and 280 BT gloves were then similarly leak-tested after 98 clean surgical procedures. The hands and gloves of scrub team members were cultured postsurgery. A total of 1/110 BT and 0/110 IT unused gloves contained leaks (NS, Fisher's exact test). Operative perforation rates were lower for BT compared with IT (8/280 cf. 22/304; P leak rates for unused gloves. Paradoxically, although IT gloves were more likely to show macro-perforations after surgery, the incidence of contamination on the surface of BT gloves was greater, possibly reflecting a qualitative difference in glove material. This study suggests that both types of gloves develop microporosity during use, which may allow transfer of bacteria from the surgeon's skin to the surface of the glove.

  18. The Efficacy of Anti-vibration Gloves

    Science.gov (United States)

    Hewitt, Sue; Dong, Ren; McDowell, Tom; Welcome, Daniel

    2016-01-01

    Anyone seeking to control the risks from vibration transmitted to the hands and arms may contemplate the use of anti-vibration gloves. To make an informed decision about any type of personal protective equipment, it is necessary to have performance data that allow the degree of protection to be estimated. The information provided with an anti-vibration glove may not be easy to understand without some background knowledge of how gloves are tested and does not provide any clear route for estimating likely protection. Some of the factors that influence the potential efficacy of an anti-vibration glove include how risks from hand–arm vibration exposure are assessed, how the standard test for a glove is carried out, the frequency range and direction of the vibration for which protection is sought, how much hand contact force or pressure is applied and the physical limitations due to glove material and construction. This paper reviews some of the background issues that are useful for potential purchasers of anti-vibration gloves. Ultimately, anti-vibration gloves cannot be relied on to provide sufficient and consistent protection to the wearer and before their use is contemplated all other available means of vibration control ought first to be implemented. PMID:27582615

  19. How risky are pinholes in gloves? A rational appeal for the integrity of gloves for isolators.

    Science.gov (United States)

    Gessler, Angela; Stärk, Alexandra; Sigwarth, Volker; Moirandat, Claude

    2011-01-01

    Isolators provide a high degree of protection for the product and/or the environment and operators in pharmaceutical production, as well as for analytical and sterility testing. Gloves allow for performing testing and for easy access to the process. Due to their nature-thin plastic, highly flexible-and their risk of puncture or rupture, they are regarded as one of the main potential sources of contamination. Glove integrity testing is therefore a main issue and has been addressed by many regulations such as those imposed by the USP, U.S. Food and Drug Administration, and Pharmaceutical Inspection Convention. This paper presents a short overview of different glove integrity test procedures and their ability to detect leaking gloves. Additionally, extensive microbiological tests have been performed to give more evidence and cross-correlation to physical testing. Most of the physical tests have limitations either in detecting pinholes and/or they are difficult to implement for routine testing. Microbiological tests are only applicable for evaluation and validation purposes, but not for routine testing, because they are time-consuming and do not allow immediate action. Routine visual verification of gloves by trained personnel turns out to be a very reliable technique. Additional microbiological tests supported by microbiological environmental monitoring helped to develop a new concept presented here on how to handle gloves with pinholes. It is proposed not to automatically consider a pinhole in a glove as a breach in isolator integrity, but to consider any action in view of controlling and monitoring the effective bioload on the outside of the gloves. With the combination of semi-automatic physical testing with independent protocol, visual inspection, and control of bioload through microbiological environmental monitoring potential contamination, risks can be minimized and maximum safety maintained. Isolators are enclosure designs to protect critical handling and

  20. Glove Perforations During Interventional Radiological Procedures

    International Nuclear Information System (INIS)

    Leena, R. V.; Shyamkumar, N. K.

    2010-01-01

    Intact surgical gloves are essential to avoid contact with blood and other body fluids. The objective of this study was to estimate the incidence of glove perforations during interventional radiological procedures. In this study, a total of 758 gloves used in 94 interventional radiological procedures were examined for perforations. Eleven perforations were encountered, only one of which was of occult type. No significant difference in the frequency of glove perforation was found between the categories with varying time duration.

  1. Glove material, reservoir formation, and dose affect glove permeation and subsequent skin penetration

    DEFF Research Database (Denmark)

    Nielsen, Jesper Bo; Sørensen, Jens Ahm

    2012-01-01

    Protective gloves are used to reduce dermal exposure when managing chemical exposures at the work place. Different glove materials may offer different degrees of protection. The present study combined the traditional ASTM (American Society for Testing and Materials) model with the Franz diffusion...

  2. Glove use among hairdressers: difficulties in the correct use of gloves among hairdressers and the effect of education.

    Science.gov (United States)

    Oreskov, Katia W; Søsted, Heidi; Johansen, Jeanne D

    2015-06-01

    Hand eczema is frequent among Danish hairdressers, and they are advised to use gloves as protection. However, studies indicate that a significant proportion use gloves inappropriately. To determine whether hairdressers and apprentices use protective gloves in the correct way, and to determine whether a demonstration of correct use could cause an improvement. Forty-three hairdressers and apprentices were asked to perform a hair wash while wearing gloves. The shampoo used was contaminated with an ultraviolet (UV) trace material. Two rounds of hair washing were carried out by each person, interrupted by a demonstration of how to use gloves correctly. Photographs were taken to compare UV contamination before and after the demonstration. All of the participants (100%) had their hands contaminated during the first round; the area ranged between 0.02 and 101.37 cm(2) (median 3.62 cm(2)). In the second round, 55.8% were contaminated (range 0.00-3.08 cm(2) ; median 0.01 cm(2)). The reduction in contaminated skin areas was statistically significant (p glove demonstration. There were no significant differences between hairdressers and apprentices. Hairdressers and apprentices lack knowledge on how to handle gloves correctly. A short demonstration of correct glove use made a significant difference in the skin protection provided by gloves. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Development of the conductive glove for glove box operation. Production of prototypes and their experimental results

    International Nuclear Information System (INIS)

    Kodato, Kazuo; Enuma, Masahito; Kawasaki, Takeshi; Nogami, Yoshitaka; Kaneko, Kazunori; Kimura, Masanori; Yasumori, Tomokazu

    2014-02-01

    The glove used at glove boxes in the nuclear fuel plants is usually made with Chlorosulfonated polyethylene rubber. The rubber is excellent in terms of resistance to radiation because it has no double bond in its main chain of the component, however, it deteriorates rapidly in high dose environment such as direct contact of alpha ray. Plutonium oxide powder is treated in glove boxes at plutonium fuel facilities where the alpha ray from plutonium oxide powder adhered on surface of a glove causes the deterioration of the rubber. Therefore the effective method for prevent of the rapid deterioration is to decrease the amount of adhered powder, and the glove with conductive property which can prevent static electric charge on its surface has been developed and tested. The results showed that the rubber has less adherent property to powder compared with conventional one. (author)

  4. Mastitis Control: take up the gloves!

    NARCIS (Netherlands)

    Jansen, J.; Renes, R.J.; Lam, T.J.G.M.

    2009-01-01

    This study shows the results of a communication campaign to increase the use of milkers gloves at Dutch dairy farms. Wearing milkers gloves is recommended as a proper method to reduce the risk of transmitting infections during milking. In 2004 only 16 percent of the Dutch dairy farmer used gloves

  5. Glove holder system for containment shell

    International Nuclear Information System (INIS)

    Picco, B.

    1993-01-01

    A glove holder for an isolated chamber used e.g. for handling toxic or radioactive materials and made with at least one access port in its wall, equipped with a ring to which the glove is attached, has a sleeve which connects the ring to the glove proper and protects the forarm. The sleeve is in at least two sections, a first corrugated section and a second, supple section which is able to fold inside the first section. ADVANTAGE - Reduced costs and quantity of waste produced by enabling glove proper only to be replaced. (author)

  6. 21 CFR 878.4460 - Surgeon's glove.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Surgeon's glove. 878.4460 Section 878.4460 Food... DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4460 Surgeon's glove. (a) Identification. A surgeon's glove is a device made of natural or synthetic rubber intended to be worn by...

  7. High Performance EVA Glove Collaboration: Glove Injury Data Mining Effort

    Science.gov (United States)

    Reid, C. R.; Benson, E.; England, S.; Charvat, J.; Norcross, J. R.; McFarland, S. M.; Rajulu, S.

    2015-01-01

    Human hands play a significant role during Extravehicular Activity (EVA) missions and Neutral Buoyancy Lab (NBL) training events, as they are needed for translating and performing tasks in the weightless environment. Because of this high frequency usage, hand and arm related injuries are known to occur during EVA and EVA training in the NBL. The primary objectives of this investigation were to: 1) document all known EVA glove related injuries and circumstances of these incidents, 2) determine likely risk factors, and 3) recommend interventions where possible that could be implemented in the current and future glove designs. METHODS: The investigation focused on the discomforts and injuries of U.S. crewmembers who had worn the pressurized Extravehicular Mobility Unit (EMU) spacesuit and experienced 4000 Series or Phase VI glove related incidents during 1981 to 2010 for either EVA ground training or in-orbit flight. We conducted an observational retrospective case-control investigation using 1) a literature review of known injuries, 2) data mining of crew injury, glove sizing, and hand anthropometry databases, 3) descriptive statistical analyses, and finally 4) statistical risk correlation and predictor analyses to better understand injury prevalence and potential causation. Specific predictor statistical analyses included use of principal component analyses (PCA), multiple logistic regression, and survival analyses (Cox proportional hazards regression). Results of these analyses were computed risk variables in the forms of odds ratios (likelihood of an injury occurring given the magnitude of a risk variable) and hazard ratios (likelihood of time to injury occurrence). Due to the exploratory nature of this investigation, we selected predictor variables significant at p=0.15. RESULTS: Through 2010, there have been a total of 330 NASA crewmembers, from which 96 crewmembers performed 322 EVAs during 1981-2010, resulting in 50 crewmembers being injured inflight and 44

  8. Hand hygiene compliance in a universal gloving setting.

    Science.gov (United States)

    Kuruno, Noriko; Kasahara, Kei; Mikasa, Keiichi

    2017-08-01

    The use of gloves for every patient contact (ie, universal gloving) has been suggested as an infection prevention adjunct and alternative to contact precautions. However, gloves may carry organisms unless they are changed properly. In addition, hand hygiene is required before donning and after removing gloves, and there are scarce data regarding glove changing and hand hygiene in a universal gloving setting. This nonrandomized observational before-after study evaluated the effect of education and feedback regarding hand hygiene. Compliance with hand hygiene and glove use was directly observed in a universal gloving setting at a 10-bed intensive care unit in a Japanese tertiary care university teaching hospital. A total of 6,050 hand hygiene opportunities were identified. Overall, hand hygiene compliance steadily increased from study period 1 (16.1%) to period 5 (56.8%), although there were indication-specific differences in the baseline compliance, the degree of improvement, and the reasons for noncompliance. There were decreases in the compliance with universal gloving and the incidence of methicillin-resistant Staphylococcus aureus. It is difficult to properly perform glove use and hand hygiene in a universal gloving setting, given its complexity. Direct observation with specific feedback and education may be effective in improving compliance. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  9. Assessment of skin exposure to N,N-dimethylformamide and methyl ethylketone through chemical protective gloves and decontamination of gloves for reuse purposes.

    Science.gov (United States)

    Chao, Keh-Ping; Wang, Ping; Chen, Chen-Peng; Tang, Ping-Yu

    2011-02-15

    N,N-dimethylformamide (DMF) and methyl ethylketone (MEK) are the hazardous chemicals commonly used in the synthetic leather industries. Although chemical protective gloves provide adequate skin exposure protection to workers in these industries, there is currently no clear guideline or understanding with regard to the use duration of these gloves. In this study, the permeation of DMF/MEK mixture through neoprene gloves and the desorption of chemicals from contaminated gloves were conducted using the ASTM F739 cell. The acceptable use duration time of the gloves against DMF/MEK permeation was estimated by assuming a critical body burden of chemical exposure as a result of dermal absorption. In a re-exposure cycle of 5 days, decontamination of the gloves by aeration at 25°C was found to be inadequate in a reduction of breakthrough time as compared to a new unexposed glove. However, decontamination of the gloves by heating at 70 or 100°C showed that the protective coefficient of the exposed gloves had similar levels of resistance to DMF/MEK as that of new gloves. Implications of this study include an understanding of the use duration of neoprene gloves and proper decontamination of chemical protective gloves for reuse. Copyright © 2010 Elsevier B.V. All rights reserved.

  10. The use of protective gloves by medical personnel.

    Science.gov (United States)

    Garus-Pakowska, Anna; Sobala, Wojciech; Szatko, Franciszek

    2013-06-01

    To minimize the risk of cross-infection between the patient and the medical staff, it is necessary to use individual protective measures such as gloves. According to the recommendations of the Centers for Disease Control and Prevention (CDC) and the World Health Organization (WHO), protective gloves should always be used upon contact with blood, mucosa, injured skin or other potentially infectious material. The aim of the study was to evaluate, through quasi-observation, the use of protective gloves by medical staff according to the guidelines issued by the CDC and WHO. The results were subject to statistical analysis (p gloves is demanded from the medical staff. The overall percentage of the observance of using gloves was 50%. The use of gloves depended significantly on the type of ward, profession, performed activity, number of situations that require wearing gloves during the observation unit and the real workload. During the entire study, as many as 718 contacts with patients were observed in which the same gloves were used several times. Wearing disposable protective gloves by the medical staff is insufficient.

  11. Seismic stability of a standalone glove box structure

    Energy Technology Data Exchange (ETDEWEB)

    Saraswat, A., E-mail: anupams@barc.gov.in [Bhabha Atomic Research Centre, Mumbai (India); Reddy, G.R. [Bhabha Atomic Research Centre, Mumbai (India); Ghosh, S. [Indian Institute of Technology Bombay, Mumbai (India); Ghosh, A.K.; Kumar, Arun [Bhabha Atomic Research Centre, Mumbai (India)

    2014-09-15

    Highlights: • Glove box is a leak tight, safety related structure used for handling radiotoxic materials. • To study the seismic performance of a freestanding glove box, extensive shake table testing has been carried out. • Glove box maintained structural integrity and leak tightness up to design basis earthquake loading. • Detailed three-dimensional finite element model of the structure is developed and analyzed by using direct time integration methods. • Simplified numerical method is proposed and successfully applied, to quickly estimate sliding displacement and determine upper bounds for it. - Abstract: In a nuclear fuel cycle facility, radiotoxic materials are being handled in freestanding leak tight enclosures called glove boxes (GBs). These glove boxes act as a primary confinement for the radiotoxic materials. Glove boxes are designed as per codal requirements for class I component. They are designed to withstand extreme level of earthquake loading with a return period of 10,000 years. To evaluate seismic performance of the glove box, there is a need to check the stability (sliding and overturning), structural integrity (stresses and strains) and leak tightness under earthquake loading. Extensive shake table experiments were conducted on a single standalone glove box. Actual laboratory conditions were simulated during testing to check the response. After extensive shake table testing, glove box structure was also analyzed using finite element (FE) software. Detailed three-dimensional model of glove box structure was developed and analyzed using nonlinear time history method. It was observed that finite element methods could be utilized to accurately predict dynamic response of glove box structure. This paper discusses the details and results of shake table testing and methodology used for modelling and analysing freestanding glove box structure under seismic loading. In addition, simplified numerical procedure, developed using energy conservation

  12. Seismic stability of a standalone glove box structure

    International Nuclear Information System (INIS)

    Saraswat, A.; Reddy, G.R.; Ghosh, S.; Ghosh, A.K.; Kumar, Arun

    2014-01-01

    Highlights: • Glove box is a leak tight, safety related structure used for handling radiotoxic materials. • To study the seismic performance of a freestanding glove box, extensive shake table testing has been carried out. • Glove box maintained structural integrity and leak tightness up to design basis earthquake loading. • Detailed three-dimensional finite element model of the structure is developed and analyzed by using direct time integration methods. • Simplified numerical method is proposed and successfully applied, to quickly estimate sliding displacement and determine upper bounds for it. - Abstract: In a nuclear fuel cycle facility, radiotoxic materials are being handled in freestanding leak tight enclosures called glove boxes (GBs). These glove boxes act as a primary confinement for the radiotoxic materials. Glove boxes are designed as per codal requirements for class I component. They are designed to withstand extreme level of earthquake loading with a return period of 10,000 years. To evaluate seismic performance of the glove box, there is a need to check the stability (sliding and overturning), structural integrity (stresses and strains) and leak tightness under earthquake loading. Extensive shake table experiments were conducted on a single standalone glove box. Actual laboratory conditions were simulated during testing to check the response. After extensive shake table testing, glove box structure was also analyzed using finite element (FE) software. Detailed three-dimensional model of glove box structure was developed and analyzed using nonlinear time history method. It was observed that finite element methods could be utilized to accurately predict dynamic response of glove box structure. This paper discusses the details and results of shake table testing and methodology used for modelling and analysing freestanding glove box structure under seismic loading. In addition, simplified numerical procedure, developed using energy conservation

  13. Glove and gown effects on intraoperative bacterial contamination.

    Science.gov (United States)

    Ward, William G; Cooper, Joshua M; Lippert, Dylan; Kablawi, Rawan O; Neiberg, Rebecca H; Sherertz, Robert J

    2014-03-01

    Experiments were performed to determine the risk of bacterial contamination associated with changing outer gloves and using disposable spunlace paper versus reusable cloth gowns. Despite decades of research, there remains a lack of consensus regarding certain aspects of optimal aseptic technique including outer glove exchange while double-gloving and surgical gown type selection. In an initial glove study, 102 surgical team members were randomized to exchange or retain outer gloves 1 hour into clean orthopedic procedures; cultures were obtained 15 minutes later from the palm of the surgeon's dominant gloved hand and from the surgical gown sleeve. Surgical gown type selection was recorded. A laboratory strike-through study investigating bacterial transmission through cloth and paper gowns was performed with coagulase-negative staphylococci. In a follow-up glove study, 251 surgical team members, all wearing paper gowns, were randomized as in the first glove study. Glove study 1 revealed 4-fold higher levels of baseline bacterial contamination (31% vs 7%) on the sleeve of surgical team members wearing cloth gowns than those using paper gowns [odds ratio (95% confidence interval): 4.64 (1.72-12.53); P = 0.0016]. The bacterial strike-through study revealed that 26 of 27 cloth gowns allowed bacterial transmission through the material compared with 0 of 27 paper gowns (P < 0.001). In glove study 2, surgeons retaining outer gloves 1 hour into the case had a subsequent positive glove contamination rate of 23% compared with 13% among surgeons exchanging their original outer glove [odds ratio (95% confidence interval): 1.97 (1.02-3.80); P = 0.0419]. Paper gowns demonstrated less bacterial transmission in the laboratory and lower rates of contamination in the operating room. Disposable paper gowns are recommended for all surgical cases, especially those involving implants, because of the heightened risk of infection. Outer glove exchange just before handling implant materials

  14. Handling chemotherapy drugs-Do medical gloves really protect?

    Science.gov (United States)

    Landeck, Lilla; Gonzalez, Ernesto; Koch, Olaf Manfred

    2015-10-15

    Due to their potential mutagenic, carcinogenic and teratogenic effects occupational exposure to chemotherapy drugs should be kept to a minimum. Utilization of personnel protective devices, especially the use of protective medical gloves, is a mainstay to avoid skin contact. The choice of appropriate gloves is of outstanding importance. For optimal protection in the oncology setting it is essential to establish general guidelines evaluating appropriate materials and defining quality standards. Establishing these guidelines can facilitate better handling and avoid potential hazards and late sequelae. In Europe there are no specific requirements or test methodologies for medical gloves used in the oncology environment. The implementation of uniform standards for gloves used while handling chemotherapy drugs would be desirable. In contrast, in the US medical gloves used to handle chemotherapy drugs have to fulfill requirements according to the ASTM International (American Society of Testing and Materials) standard D 6978-05. Nitrile or natural rubber latex is a preferred basic glove material, while vinyl is considered inappropriate because of its generally increased permeability. For extended exposure to chemotherapy drugs, double gloving, the use of thicker gloves and the frequent change of gloves increases their protective power. © 2014 UICC.

  15. Permeation of Comite through protective gloves.

    Science.gov (United States)

    Zainal, Hanaa; Que Hee, Shane S

    2006-09-01

    The goal of the study was to assess how protective disposable (Safeskin) and chemical protective (Sol-Vex) nitrile gloves were against Comite emulsifiable concentrate formulation containing propargite (PROP) as active pesticidal ingredient, because there were no explicit recommendations for the gloves that should be worn for hand protection. The glove material was exposed in ASTM-type I-PTC-600 permeation cells at 30.0+/-0.5 degrees C, and gas chromatography-mass spectrometry used for PROP analysis. Aqueous solutions of Comite at 40.4 mg/mL permeated both Safeskin and Sol-Vex nitrile by 8h. Safeskin showed a mean PROP mass permeated of 176+/-27 microg after 8h compared with a mean mass permeated for Sol-Vex of 3.17+/-4.08 microg. Thus, Sol-Vex was about 56 times more protective than Safeskin for an 8-h exposure. However, the kinetics of the permeation revealed that Safeskin can be worn for at least 200 min before disposal. When undiluted Comite challenged both types of nitrile, much faster permeation was observed. Safeskin gloves showed two steady state periods. The first had lag times (t(l)) values of about 1h, although normalized breakthrough times (t(b)) were gloves exposed continuously to undiluted Comite permeated above the normalized breakthrough threshold beyond 2.7h. A risk assessment revealed that the PROP skin permeation rate of 7.1 ng cm(-2)h(-1) was much slower than the first steady state Safeskin glove P(s) of 62,000 ng cm(-2)h(-1). Infrared analysis showed that the glove surfaces were not degraded by the Comite challenge. The chemically protective Sol-Vex gloves protected adequately against undiluted formulation for about 2.7h, whereas they provided protection for nearly 8h when the formulation was diluted with water to the highest concentration for field application. In contrast, the disposable Safeskin gloves did not protect at all for the undiluted formulation, but did for 200 min when the formulation was diluted with water to the highest

  16. Wearing gloves in the hospital

    Science.gov (United States)

    ... your bare hands. Follow these steps: Grab the top of your right glove with your left hand. Pull toward your fingertips. ... hand. Put 2 right-hand fingers in the top of your left glove. Pull toward your fingertips until you have pulled ...

  17. The use of protective gloves by medical personnel

    Directory of Open Access Journals (Sweden)

    Anna Garus-Pakowska

    2013-06-01

    Full Text Available Introduction: To minimize the risk of cross-infection between the patient and the medical staff, it is necessary to use individual protective measures such as gloves. According to the recommendations of the Centers for Disease Control and Prevention (CDC and the World Health Organization (WHO, protective gloves should always be used upon contact with blood, mucosa, injured skin or other potentially infectious material. Materials and Methods: The aim of the study was to evaluate, through quasi-observation, the use of protective gloves by medical staff according to the guidelines issued by the CDC and WHO. The results were subject to statistical analysis (p < 0.05. Results: During 1544 hours of observations, 3498 situations were recorded in which wearing protective gloves is demanded from the medical staff. The overall percentage of the observance of using gloves was 50%. The use of gloves depended significantly on the type of ward, profession, performed activity, number of situations that require wearing gloves during the observation unit and the real workload. During the entire study, as many as 718 contacts with patients were observed in which the same gloves were used several times. Conclusion: Wearing disposable protective gloves by the medical staff is insufficient.

  18. Performance Analysis of Exam Gloves Used for Aseptic Rodent Surgery

    Science.gov (United States)

    LeMoine, Dana M; Bergdall, Valerie K; Freed, Carrie

    2015-01-01

    Aseptic technique includes the use of sterile surgical gloves for survival surgeries in rodents to minimize the incidence of infections. Exam gloves are much less expensive than are surgical gloves and may represent a cost-effective, readily available option for use in rodent surgery. This study examined the effectiveness of surface disinfection of exam gloves with 70% isopropyl alcohol or a solution of hydrogen peroxide and peracetic acid (HP–PA) in reducing bacterial contamination. Performance levels for asepsis were met when gloves were negative for bacterial contamination after surface disinfection and sham ‘exertion’ activity. According to these criteria, 94% of HP–PA-disinfected gloves passed, compared with 47% of alcohol-disinfected gloves. In addition, the effect of autoclaving on the integrity of exam gloves was examined, given that autoclaving is another readily available option for aseptic preparation. Performance criteria for glove integrity after autoclaving consisted of: the ability to don the gloves followed by successful simulation of wound closure and completion of stretch tests without tearing or observable defects. Using this criteria, 98% of autoclaved nitrile exam gloves and 76% of autoclaved latex exam gloves met performance expectations compared with the performance of standard surgical gloves (88% nitrile, 100% latex). The results of this study support the use of HP–PA-disinfected latex and nitrile exam gloves or autoclaved nitrile exam gloves as viable cost-effective alternatives to sterile surgical gloves for rodent surgeries. PMID:26045458

  19. Performance analysis of exam gloves used for aseptic rodent surgery.

    Science.gov (United States)

    LeMoine, Dana M; Bergdall, Valerie K; Freed, Carrie

    2015-05-01

    Aseptic technique includes the use of sterile surgical gloves for survival surgeries in rodents to minimize the incidence of infections. Exam gloves are much less expensive than are surgical gloves and may represent a cost-effective, readily available option for use in rodent surgery. This study examined the effectiveness of surface disinfection of exam gloves with 70% isopropyl alcohol or a solution of hydrogen peroxide and peracetic acid (HP-PA) in reducing bacterial contamination. Performance levels for asepsis were met when gloves were negative for bacterial contamination after surface disinfection and sham 'exertion' activity. According to these criteria, 94% of HP-PA-disinfected gloves passed, compared with 47% of alcohol-disinfected gloves. In addition, the effect of autoclaving on the integrity of exam gloves was examined, given that autoclaving is another readily available option for aseptic preparation. Performance criteria for glove integrity after autoclaving consisted of: the ability to don the gloves followed by successful simulation of wound closure and completion of stretch tests without tearing or observable defects. Using this criteria, 98% of autoclaved nitrile exam gloves and 76% of autoclaved latex exam gloves met performance expectations compared with the performance of standard surgical gloves (88% nitrile, 100% latex). The results of this study support the use of HP-PA-disinfected latex and nitrile exam gloves or autoclaved nitrile exam gloves as viable cost-effective alternatives to sterile surgical gloves for rodent surgeries.

  20. 21 CFR 880.6250 - Patient examination glove.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Patient examination glove. 880.6250 Section 880.6250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... Devices § 880.6250 Patient examination glove. (a) Identification. A patient examination glove is a...

  1. The effects of vibration-reducing gloves on finger vibration

    Science.gov (United States)

    Welcome, Daniel E.; Dong, Ren G.; Xu, Xueyan S.; Warren, Christopher; McDowell, Thomas W.

    2015-01-01

    Vibration-reducing (VR) gloves have been used to reduce the hand-transmitted vibration exposures from machines and powered hand tools but their effectiveness remains unclear, especially for finger protection. The objectives of this study are to determine whether VR gloves can attenuate the vibration transmitted to the fingers and to enhance the understanding of the mechanisms of how these gloves work. Seven adult male subjects participated in the experiment. The fixed factors evaluated include hand force (four levels), glove condition (gel-filled, air bladder, no gloves), and location of the finger vibration measurement. A 3-D laser vibrometer was used to measure the vibrations on the fingers with and without wearing a glove on a 3-D hand-arm vibration test system. This study finds that the effect of VR gloves on the finger vibration depends on not only the gloves but also their influence on the distribution of the finger contact stiffness and the grip effort. As a result, the gloves increase the vibration in the fingertip area but marginally reduce the vibration in the proximal area at some frequencies below 100 Hz. On average, the gloves reduce the vibration of the entire fingers by less than 3% at frequencies below 80 Hz but increase at frequencies from 80 to 400 Hz. At higher frequencies, the gel-filled glove is more effective at reducing the finger vibration than the air bladder-filled glove. The implications of these findings are discussed. Relevance to industry Prolonged, intensive exposure to hand-transmitted vibration can cause hand-arm vibration syndrome. Vibration-reducing gloves have been used as an alternative approach to reduce the vibration exposure. However, their effectiveness for reducing finger-transmitted vibrations remains unclear. This study enhanced the understanding of the glove effects on finger vibration and provided useful information on the effectiveness of typical VR gloves at reducing the vibration transmitted to the fingers. The new

  2. Glove-Enabled Computer Operations (GECO): Design and Testing of an Extravehicular Activity Glove Adapted for Human-Computer Interface

    Science.gov (United States)

    Adams, Richard J.; Olowin, Aaron; Krepkovich, Eileen; Hannaford, Blake; Lindsay, Jack I. C.; Homer, Peter; Patrie, James T.; Sands, O. Scott

    2013-01-01

    The Glove-Enabled Computer Operations (GECO) system enables an extravehicular activity (EVA) glove to be dual-purposed as a human-computer interface device. This paper describes the design and human participant testing of a right-handed GECO glove in a pressurized glove box. As part of an investigation into the usability of the GECO system for EVA data entry, twenty participants were asked to complete activities including (1) a Simon Says Games in which they attempted to duplicate random sequences of targeted finger strikes and (2) a Text Entry activity in which they used the GECO glove to enter target phrases in two different virtual keyboard modes. In a within-subjects design, both activities were performed both with and without vibrotactile feedback. Participants mean accuracies in correctly generating finger strikes with the pressurized glove were surprisingly high, both with and without the benefit of tactile feedback. Five of the subjects achieved mean accuracies exceeding 99 in both conditions. In Text Entry, tactile feedback provided a statistically significant performance benefit, quantified by characters entered per minute, as well as reduction in error rate. Secondary analyses of responses to a NASA Task Loader Index (TLX) subjective workload assessments reveal a benefit for tactile feedback in GECO glove use for data entry. This first-ever investigation of employment of a pressurized EVA glove for human-computer interface opens up a wide range of future applications, including text chat communications, manipulation of procedureschecklists, cataloguingannotating images, scientific note taking, human-robot interaction, and control of suit andor other EVA systems.

  3. Wearing ambidextrous vinyl gloves does not impair manual dexterity.

    Science.gov (United States)

    Drabek, Tomas; Boucek, Charles D; Buffington, Charles W

    2013-01-01

    Universal precautions mandate that health care workers wear gloves to prevent the unintended spread of bloodborne pathogens. Gloves may affect manual dexterity, generally delaying task completion. Our previous study showed that wearing the wrong size latex surgical glove degraded manual dexterity. The use of non-sterile and non-latex gloves may limit certain risks and be more cost-effective. However, such gloves may produce different results. We hypothesized that ambidextrous vinyl examination gloves would degrade manual dexterity compared with bare hands. We studied 20 random subjects from a medical environment. Subjects performed a standard battery of Grooved Pegboard tasks while bare-handed, wearing ambidextrous non-sterile vinyl gloves that were their preferred size, a size too small, and a size too large. The order was randomized with a Latin Square design to minimize the effects of time, boredom, and fatigue on the subjects. Subjects were also invited to comment on the fit of different size gloves. Wearing vinyl gloves of both the preferred size and a size up or down failed to affect manual dexterity vs. bare hands on time to insert pegs, and pegs dropped during insertion or removal. In contrast, the time to remove pegs was reduced by wearing preferred size vinyl gloves compared with performing the task with bare hands (Pgloves that were too small caused significant hand discomfort. Vinyl gloves surprisingly do not degrade manual dexterity even when worn in ill-fitting sizes. Wearing a preferred size vinyl glove vs. bare hands may improve dexterity in selected tasks. Choosing a comfortable, large size seems the best strategy when the preferred size is unavailable. Thinner vinyl gloves may improve grip and may not degrade touch as much as latex surgical gloves and may thus represent a reasonable choice for selected tasks.

  4. Flexible protective gloves: The emperor's new clothes

    International Nuclear Information System (INIS)

    Kelsey, C.A.; Mettler, F.A. Jr.

    1990-01-01

    The risk of developing skin cancer is estimated for interventional radiologists who do and do not wear thin, flexible protective leaded gloves. The use of these gloves is extremely expensive in terms of dollars per potential cancer prevented. Good radiographic practice without the use of flexible protective gloves provides adequate protection

  5. Initial Work Toward a Robotically Assisted EVA Glove

    Science.gov (United States)

    Rogers, J.; Peters, B.; McBryan, E.; Laske, E.

    2016-01-01

    The Space Suit RoboGlove is a device designed to provide additional grasp strength or endurance for an EVA crew member since gloved hand performance is a fraction of what the unencumbered human hand can achieve. There have been past efforts to approach this problem by employing novel materials and construction techniques to the glove design, as well as integrating powered assistance devices. This application of the NASA/GM RoboGlove technology uses a unique approach to integrate the robotic actuators and sensors into a Phase VI EVA glove. This design provides grasp augmentation to the glove user while active, but can also function as a normal glove when disabled. Care was taken to avoid adding excessive bulk to the glove or affecting tactility by choosing low-profile sensors and extrinsically locating the actuators. Conduits are used to guide robotic tendons from linear actuators, across the wrist, and to the fingers. The second generation of the SSRG includes updated electronics, sensors, and actuators to improve performance. The following discusses the electromechanical design, softgoods integration, and control system of the SSRG. It also presents test results from the first integration of a powered mobility element onto a space suit, the NASA Mark III. Early results show that sensor integration did not impact tactile feedback in the glove and the actuators show potential for reduction in grasp fatigue over time.

  6. Glove boxes. Dimensions and requirements. Draft

    International Nuclear Information System (INIS)

    1985-07-01

    The standard is to be applied to work done in glove-boxes, whereby either the personnel need to be protected from the damaging effects of the materials being handled, or the materials from the effects of the environment. It is to be applied to glove-boxes in which substances are handled which emit ionising radiation (radioactive substances). This norm is not restricted to glove-boxes in which processes are carried out on a technique scale. In accordance with this norm, only those pressures and temperatures are allowed to be present in the glove-boxes, that do not offer significantly from the work areas. Alongside the stipulations of this standard regard is also always to be taken of the regulations in the radiation protection ordinance. (orig./HP) [de

  7. Glove corrosive liquid immersion and permeability study

    International Nuclear Information System (INIS)

    Middleton, H.W.

    1977-01-01

    The Occupational Safety and Health Administration's requirement for protective equipment for personnel working with chemical hazards resulted in a study of gloves used in work with corrosive liquids. Gloves of different materials and weights were tested using ASTM methods, in various corrosive liquids. Results show the best material for gloves used for different lengths of time in the liquids

  8. Health risk assessments of DEHP released from chemical protective gloves.

    Science.gov (United States)

    Chao, Keh-Ping; Huang, Chan-Sheng; Wei, Chung-Ying

    2015-01-01

    The substance di-2-ethylhexyl phthalate (DEHP) is widely used as a plasticizer in chemical protective gloves to improve their flexibility and workability. However, it is possible that workers using protective gloves to handle various solvents may be exposed to DEHP leached by the solvents. Using an ASTM F739 permeation cell, it was found that BTEX solvents permeating through the glove samples dissolved DEHP from the gloves. Even without continuously contacting the permeant, DEHP was released from the contaminated glove samples during the desorption experiments. The DEHP leaching amounts were found to be inversely correlated to the permeability coefficients of BTEX in the glove samples. This result implied that the larger the amount of DEHP released from the glove samples, the higher the permeation resistance of gloves. Although chemical protective gloves provide adequate skin exposure protection to workers, the dermal exposure model developed herein indicates that leaching of DEHP from the glove samples may pose a potential health risk to the workers who handle BTEX. This study suggests that the selection of protective gloves should not only be concerned with the chemical resistance of the gloves but also the health risk associated with leaching of chemicals, such as DEHP, used in the manufacturing of the gloves. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Next Generation Life Support: High Performance EVA Glove

    Science.gov (United States)

    Walsh, Sarah K.

    2015-01-01

    The objectives of the High Performance EVA Glove task are to develop advanced EVA gloves for future human space exploration missions and generate corresponding standards by which progress may be quantitatively assessed. New technologies and manufacturing techniques will be incorporated into the new gloves to address finger and hand mobility, injury reduction and durability in nonpristine environments. Three prototypes will be developed, each focusing on different technological advances. A robotic assist glove will integrate a powered grasping system into the current EVA glove design to reduce astronaut hand fatigue and hand injuries. A mechanical counter pressure (MCP) glove will be developed to further explore the potential of MCP technology and assess its capability for countering the effects of vacuum or low pressure environments on the body by using compression fabrics or materials to apply the necessary pressure. A gas pressurized glove, incorporating new technologies, will be the most flight-like of the three prototypes. Advancements include the development and integration of aerogel insulation, damage sensing components, dust-repellant coatings, and dust tolerant bearings.

  10. Develop and Manufacture an Ergonomically Sound Glovebox Glove Report

    Energy Technology Data Exchange (ETDEWEB)

    Lawton, Cindy M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-10-18

    Ergonomic injury and radiation exposure are two safety concerns for the Plutonium Facility at Los Alamos National Laboratory (LANL). This facility employs the largest number of gloveboxes (GB) at LANL with approximately 6000 gloves installed. The current GB glove design dates back to the 1960’s and is not based on true hand anatomy, revealing several issues: short fingers, inappropriate length from the wrist to finger webbing, nonexistent joint angles and incorrect thumb placement. These design flaws are directly related to elbow (lateral epicondylitis) and thumb (DeQuervain’s tenosynovitis) injuries. The current design also contributes to increased wear on the glove, causing unplanned glove openings (failures) which places workers at risk of exposure. An improved glovebox glove design has three significant benefits: 1) it will reduce the risk of injury, 2) it will improve comfort and productivity, and 3) it will reduce the risk of a glovebox failures. The combination of these three benefits has estimated savings of several million dollars. The new glove design incorporated the varied physical attributes of workers ranging from the 5th percentile female to the 95th percentile male. Anthropometric hand dimensions along with current GB worker dimensions were used to develop the most comprehensive design specifications for the new glove. Collaboration with orthopedic hand surgeons also provided major contributtions to the design. The new glovebox glove was developed and manufactured incorporating over forty dimensions producing the most comprehensive ergonomically sound design. The new design received a LANL patent (patent attorney docket No: LANS 36USD1 “Protective Glove”, one of 20 highest patents awarded by the Richard P. Feynman Center for Innovation. The glove dimensions were inputed into a solid works model which was used to produce molds. The molds were then shipped to a glove manufacturer for production of the new glovebox gloves. The new

  11. Methods for reducing energy dissipation in cosmetic gloves

    NARCIS (Netherlands)

    Herder, J.L.; Cool, J.C.; Plettenburg, D.H.

    1998-01-01

    For cosmetic reasons, hand prostheses are provided with cosmetic gloves. Their pleasing appearance, however, is accompanied by poor mechanical behavior, resulting in a negative influence on prosthesis operation. Glove stiffness is high and nonlinear, and internal friction in the glove material

  12. 30 CFR 77.606-1 - Rubber gloves; minimum requirements.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Rubber gloves; minimum requirements. 77.606-1... COAL MINES Trailing Cables § 77.606-1 Rubber gloves; minimum requirements. (a) Rubber gloves (lineman's gloves) worn while handling high-voltage trailing cables shall be rated at least 20,000 volts and shall...

  13. Evaluation of surgical gloves for radiation protection

    International Nuclear Information System (INIS)

    Antolin, E.; Rot, M.J.; Ordonez, J.; Arranz, L.; Sastre, J.M.; Ferrer, N.; Andres, J.C. de

    2006-01-01

    Full text of publication follows: Accumulated doses in hands during interventionist cardiology and radiological procedures can reach high values, and even go beyond legal limits for exposed professionals after years of work, unless they use specific radiation protection methods. An important protection mean for hands is the use of surgical gloves that attenuate the radiation while maintaining the tactile sensitivity demanded by physicians.There is a wide variety of commercialized gloves for radiation protection, with different advantages and disadvantages for various uses. In this paper nine different models of gloves have been evaluated for testing its attenuation capacity for several voltages, the maintenance of tactile sensitivity, its resistance to elongation, and the apparition of pores after successive sterilizing processes. It is very important that they do not lose its initial characteristics after processes of sterilization in order to optimize the product effective cost. The attenuation values have been measured under the voltages of 60, 70, 80 and 90 KVp obtaining very different values at each voltage with different gloves. The values measured range between 34 % before any supplementary sterilization with one model of glove (for 90 KVp), and 57 % after four sterilization processes with another glove (for 60 KVp). Some gloves lose its attenuation capacity after successive sterilizations, having not been found an y significant relation with their composition. The tactile sensitivity, a decisive factor for its users, decreases as its attenuation capacity increases, and remains mostly constant after being sterilized. The tests performed allow to conclude a set of fi nal results that can facilitate the choice of the most suitable gloves according to the practical applications (the priorities being the radiation protection and the tactile sensitivity)

  14. Bacterial migration through punctured surgical gloves under real surgical conditions

    Directory of Open Access Journals (Sweden)

    Heidecke Claus-Dieter

    2010-07-01

    Full Text Available Abstract Background The aim of this study was to confirm recent results from a previous study focussing on the development of a method to measure the bacterial translocation through puncture holes in surgical gloves under real surgical conditions. Methods An established method was applied to detect bacterial migration from the operating site through the punctured glove. Biogel™ double-gloving surgical gloves were used during visceral surgeries over a 6-month period. A modified Gaschen-bag method was used to retrieve organisms from the inner glove, and thus-obtained bacteria were compared with micro-organisms detected by an intra-operative swab. Results In 20 consecutive procedures, 194 gloves (98 outer gloves, 96 inner gloves were examined. The rate of micro-perforations of the outer surgical glove was 10% with a median wearing time of 100 minutes (range: 20-175 minutes. Perforations occurred in 81% on the non-dominant hand, with the index finger most frequently (25% punctured. In six cases, bacterial migration could be demonstrated microbiologically. In 5% (5/98 of outer gloves and in 1% (1/96 of the inner gloves, bacterial migration through micro-perforations was observed. For gloves with detected micro-perforations (n = 10 outer layers, the calculated migration was 50% (n = 5. The minimum wearing time was 62 minutes, with a calculated median wearing time of 71 minutes. Conclusions This study confirms previous results that bacterial migration through unnoticed micro-perforations in surgical gloves does occur under real practical surgical conditions. Undetected perforation of surgical gloves occurs frequently. Bacterial migration from the patient through micro-perforations on the hand of surgeons was confirmed, limiting the protective barrier function of gloves if worn over longer periods.

  15. Determining the Radiation Damage Effect on Glovebox Glove Material

    International Nuclear Information System (INIS)

    Cournoyer, M.E.; Balkey, J.J.; Andrade, R.M.

    2005-01-01

    The Nuclear Material Technology (NMT) Division has the largest inventory of glove box gloves at Los Alamos National Laboratory. The minimization of unplanned breaches in the glovebox, e.g., glove failures, is a primary concern in the daily operations in NMT Division facilities, including the Plutonium Facility (PF-4) at TA-55 and Chemical and Metallurgy Research (CMR) Facility. Glovebox gloves in these facilities are exposed to elevated temperatures and exceptionally aggressive radiation environments (particulate 239 Pu and 238 Pu). Predictive models are needed to estimate glovebox glove service lifetimes, i.e. change-out intervals. Towards this aim aging studies have been initiated that correlate changes in mechanical (physical) properties with degradation chemistry. This present work derives glovebox glove change intervals based on previously reported mechanical data of thermally aged hypalon glove samples. Specifications for 30 mil tri-layered hypalon/lead glovebox gloves (TLH) and 15 mil hypalon gloves (HYP) have already been established. The relevant mechanical properties are shown on Table 1. Tensile strength is defined as the maximum load applied in breaking a tensile test piece divided by the original cross-sectional area of the test piece (Also termed maximum stress and ultimate tensile stress). Ultimate elongation is the elongation at time of rupture (Also termed maximum strain). The specification for the tensile test and ultimate elongation are the minimum acceptable values. In addition, the ultimate elongation must not vary 20% from the original value. In order to establish a service lifetimes for glovebox gloves in a thermal environment, the mechanical properties of glovebox glove materials were studied.

  16. Determining the Radiation Damage Effect on Glovebox Glove Material.

    Energy Technology Data Exchange (ETDEWEB)

    Cournoyer, M. E. (Michael E.); Balkey, J. J. (James J.); Andrade, R.M. (Rose M.)

    2005-01-01

    The Nuclear Material Technology (NMT) Division has the largest inventory of glove box gloves at Los Alamos National Laboratory. The minimization of unplanned breaches in the glovebox, e.g., glove failures, is a primary concern in the daily operations in NMT Division facilities, including the Plutonium Facility (PF-4) at TA-55 and Chemical and Metallurgy Research (CMR) Facility. Glovebox gloves in these facilities are exposed to elevated temperatures and exceptionally aggressive radiation environments (particulate {sup 239}Pu and {sup 238}Pu). Predictive models are needed to estimate glovebox glove service lifetimes, i.e. change-out intervals. Towards this aim aging studies have been initiated that correlate changes in mechanical (physical) properties with degradation chemistry. This present work derives glovebox glove change intervals based on previously reported mechanical data of thermally aged hypalon glove samples. Specifications for 30 mil tri-layered hypalon/lead glovebox gloves (TLH) and 15 mil hypalon gloves (HYP) have already been established. The relevant mechanical properties are shown on Table 1. Tensile strength is defined as the maximum load applied in breaking a tensile test piece divided by the original cross-sectional area of the test piece (Also termed maximum stress and ultimate tensile stress). Ultimate elongation is the elongation at time of rupture (Also termed maximum strain). The specification for the tensile test and ultimate elongation are the minimum acceptable values. In addition, the ultimate elongation must not vary 20% from the original value. In order to establish a service lifetimes for glovebox gloves in a thermal environment, the mechanical properties of glovebox glove materials were studied.

  17. Dexterity test data contribute to proper glovebox over-glove use

    International Nuclear Information System (INIS)

    Cournoyer, Michael E.; Lawton, Cindy M.; Castro, Armanda M.; Costigan, Stephen A.; Apel, D.M.; Neal, G.E.; Castro, J.M.; Michelotti, R.A.

    2010-01-01

    Programmatic operations at the Los Alamos National Laboratory Plutonium Facility (TA-55) involve working with various amounts of plutonium and other highly toxic, alpha-emitting materials. The spread of radiological contamination on surfaces, airborne contamination, and excursions of contaminants into the operator's breathing zone are prevented through the use of a variety of gloveboxes (the glovebox, coupled with an adequate negative pressure gradient, provides primary confinement). The glovebox gloves are the weakest part of this engineering control. The Glovebox Glove Integrity Program, which controls glovebox gloves from procurement to disposal at TA-55, manages this vulnerability. A key element of this program is to consider measures that lower the overall risk of glovebox operations. Proper selection of over-gloves is one of these measures. Line management owning glovebox processes have the responsibility to approve the appropriate personal protective equipment/glovebox glove/over-glove combination. As low as reasonably achievable (ALARA) considerations to prevent unplanned glovebox glove openings must be balanced with glove durability and worker dexterity, both of which affect the final overall risk to the worker. In this study, the causes of unplanned glovebox glove openings, the benefits of over-glove features, the effect of over-gloves on task performance using standard dexterity tests, the pollution prevention benefits, and the recommended over-gloves for a task are presented.

  18. Assessment of Protective Gloves for Use with Airfed Suits.

    Science.gov (United States)

    Millard, Claire E; Vaughan, Nicholas P

    2015-10-01

    Gloves are often needed for hand protection at work, but they can impair manual dexterity, especially if they are multilayered or ill-fitting. This article describes two studies of gloves to be worn with airfed suits (AFS) for nuclear decommissioning or containment level 4 (CL4) microbiological work. Both sets of workers wear multiple layers of gloves for protection and to accommodate decontamination procedures. Nuclear workers are also often required to wear cut-resistant gloves as an extra layer of protection. A total of 15 subjects volunteered to take part in manual dexterity testing of the different gloving systems. The subjects' hands were measured to ensure that the appropriate sized gloves were used. The gloves were tested with the subjects wearing the complete clothing ensembles appropriate to the work, using a combination of standard dexterity tests: the nine-hole peg test; a pin test adapted from the European Standard for protective gloves, the Purdue Pegboard test, and the Minnesota turning test. Specialized tests such as a hand tool test were used to test nuclear gloves, and laboratory-type manipulation tasks were used to test CL4 gloves. Subjective assessments of temperature sensation and skin wettedness were made before and after the dexterity tests of the nuclear gloves only. During all assessments, we made observations and questioned the subjects about ergonomic issues related to the clothing ensembles. Overall, the results show that the greater the thickness of the gloves and the number of layers the more the levels of manual dexterity performance are degraded. The nuclear cut-resistant gloves with the worst level of dexterity were stiff and inflexible and the subjects experienced problems picking up small items and bending their hands. The work also highlighted other factors that affect manual dexterity performance, including proper sizing, interactions with the other garments worn at the time, and the work equipment in use. In conclusion, when

  19. Indications and the requirements for single-use medical gloves

    Science.gov (United States)

    Kramer, Axel; Assadian, Ojan

    2016-01-01

    Aim: While the requirements for single-use gloves for staff protection are clearly defined, the conventional medical differentiation between “sterile surgical gloves” used during surgical procedures and “single-use medical gloves” used in non-sterile medical areas does not adequately define the different requirements in these two areas of use. Sterilization of single-use medical gloves is not performed if sterility is not required; thus, another terminology must be found to identify the safety quality of non-sterile single-use medical gloves. Therefore, the labeling of such gloves should reflect this situation, by introducing the term “pathogen-free” single-use glove. The hygienic safety of such a glove would be attainable by ensuring aseptic manufacturing conditions during manufacturing and control of pathogen load of batch controls after fabrication. Proposed recommendation: Because single-use gloves employed in non-sterile areas come into contact not only with intact skin but also with mucous membranes, no potential pathogens should be detectable in 100 mL of rinse sample. In order to declare such gloves as pathogen-free we suggest absence of the indicator species S. aureus and E. coli. In addition, the total CFU count should be evaluated, since a high load indicates lack of optimal hygiene during the manufacturing process. Based on the requirements for potable water and findings obtained from investigations of the bacterial load of such gloves after manufacturing, the here suggested limit for the total bacterial count of glove seems realistic. PMID:26816673

  20. Tensile Properties and Integrity of Clean Room and Low-Modulus Disposable Nitrile Gloves: A Comparison of Two Dissimilar Glove Types

    Science.gov (United States)

    Phalen, Robert N.; Wong, Weng kee

    2012-01-01

    Background: The selection of disposable nitrile exam gloves is complicated by (i) the availability of several types or formulations, (ii) product variability, and (iii) an inability of common quality control tests to detect small holes in the fingers. Differences in polymer formulation (e.g. filler and plasticizer/oil content) and tensile properties are expected to account for much of the observed variability in performance. Objectives: This study evaluated the tensile properties and integrity (leak failure rates) of two glove choices assumed to contain different amounts of plasticizers/oils. The primary aims were to determine if the tensile properties and integrity differed and if associations existed among these factors. Additional physical and chemical properties were evaluated. Methods: Six clean room and five low-modulus products were evaluated using the American Society for Testing and Materials Method D412 and a modified water-leak test to detect holes capable of passing a virus or chemical agent. Results: Significant differences in the leak failure rates and tensile properties existed between the two glove types (P ≤ 0.05). The clean room gloves were about three times more likely to have leak failures (chi-square; P = 0.001). No correlation was observed between leak failures and tensile properties. Solvent extract, an indication of added plasticizer/oil, was not associated with leak failures. However, gloves with a maximum modulus gloves were a better choice for protection against aqueous chemical or biological penetration. The observed variability between glove products indicated that glove selection cannot rely solely on glove type or manufacturer labeling. Measures of modulus and AD may aid in the selection process, in contrast with common measures of tensile strength and elongation at break. PMID:22201179

  1. [Migrants from disposable gloves and residual acrylonitrile].

    Science.gov (United States)

    Wakui, C; Kawamura, Y; Maitani, T

    2001-10-01

    Disposable gloves made from polyvinyl chloride with and without di(2-ethylhexyl) phthalate (PVC-DEHP, PVC-NP), polyethylene (PE), natural rubber (NR) and nitrile-butadiene rubber (NBR) were investigated with respect to evaporation residue, migrated metals, migrants and residual acrylonitrile. The evaporation residue found in n-heptane was 870-1,300 ppm from PVC-DEHP and PVC-NP, which was due to the plasticizers. Most of the PE gloves had low evaporation residue levels and migrants, except for the glove designated as antibacterial, which released copper and zinc into 4% acetic acid. For the NR and NBR gloves, the evaporation residue found in 4% acetic acid was 29-180 ppm. They also released over 10 ppm of calcium and 6 ppm of zinc into 4% acetic acid, and 1.68-8.37 ppm of zinc di-ethyldithiocarbamate and zinc di-n-butyldithiocarbamate used as vulcanization accelerators into n-heptane. The acrylonitrile content was 0.40-0.94 ppm in NBR gloves.

  2. Striking dynamics and kinetic properties of boxing and MMA gloves

    Directory of Open Access Journals (Sweden)

    Benjamin Lee

    2014-08-01

    Full Text Available With the growing popularity of Mixed Martial Arts (MMA as a competitive sport, questions regarding the dynamic response and properties of MMA gloves arise. High-energy impacts from punches are very similar to boxing yet MMA competition requires the use of 4 oz fingerless glove, compared to the larger full enclosure boxing glove. This work assessed the kinetic properties and strike dynamics of MMA gloves and compared findings with traditional boxing gloves. Gloves mounted on a molded fist were impacted repetitively on an instrumental anvil designed for impact, over a 5 hour period resulting in 10,000 continuous and consistent strikes. Kinetic data from impacts were sampled at the beginning of the data collection and subsequently every 30 minutes (every 1,000 strikes. MMA gloves produced 4-5 times greater peak force and 5 times faster load rate compared to the boxing glove. However, MMA gloves also showed signs of material fatigue, with peak force increasing by 35% and rate of loading increasing by 60% over the duration of the test. Boxing glove characteristics did deteriorate but to a lesser extent. In summary, the kinetic properties of MMA glove differed substantially from the boxing glove resulting in impacts characterized by higher peak forces and more rapid development of force. Material properties including stiffness and thickness play a role in the kinetic characteristics upon impact, and can be inferred to alter injury mechanisms of blunt force trauma.

  3. The durability of examination gloves used on intensive care units.

    Science.gov (United States)

    Hübner, Nils-Olaf; Goerdt, Anna-Maria; Mannerow, Axel; Pohrt, Ute; Heidecke, Claus-Dieter; Kramer, Axel; Partecke, Lars Ivo

    2013-05-20

    The use of examination gloves is part of the standard precautions to prevent medical staff from transmission of infectious agents between patients. Gloves also protect the staff from infectious agents originating from patients. Adequate protection, however, depends on intact gloves. The risk of perforation of examination gloves is thought to correlate with duration of wearing, yet, only very few prospective studies have been performed on this issue. A total number of 1500 consecutively used pairs of examination gloves of two different brands and materials (latex and nitrile) were collected over a period of two months on two ICU's. Used gloves were examined for micro perforations using the "water-proof-test" according to EN 455-1. Cox-regression for both glove types was used to estimate optimal changing intervals. Only 26% of gloves were worn longer than 15 min. The total perforation rate was 10.3% with significant differences and deterioration of integrity of gloves between brands (pgloves show marked differences in their durability that cannot be predicted based on the technical data routinely provided by the manufacturer. Based on the increase of micro perforations over time and the wearing behavior, recommendations for maximum wearing time of gloves should be given. Changing of gloves after 15 min could be a good compromise between feasibility and safety. HCWs should be aware of the benefits and limitations of medical gloves. To improve personal hygiene hand disinfection should be further encouraged.

  4. Evaluation of the flexibility of protective gloves.

    Science.gov (United States)

    Harrabi, Lotfi; Dolez, Patricia I; Vu-Khanh, Toan; Lara, Jaime

    2008-01-01

    Two mechanical methods have been developed for the characterization of the flexibility of protective gloves, a key factor affecting their degree of usefulness for workers. The principle of the first method is similar to the ASTM D 4032 standard relative to fabric stiffness and simulates the deformations encountered by gloves that are not tight fitted to the hand. The second method characterizes the flexibility of gloves that are worn tight fitted. Its validity was theoretically verified for elastomer materials. Both methods should prove themselves as valuable tools for protective glove manufacturers, allowing for the characterization of their existing products in terms of flexibility and the development of new ones better fitting workers' needs.

  5. Integrity of Disposable Nitrile Exam Gloves Exposed to Simulated Movement

    Science.gov (United States)

    Phalen, Robert N.; Wong, Weng Kee

    2011-01-01

    Every year, millions of health care, first responder, and industry workers are exposed to chemical and biological hazards. Disposable nitrile gloves are a common choice as both a chemical and physical barrier to these hazards, especially as an alternative to natural latex gloves. However, glove selection is complicated by the availability of several types or formulations of nitrile gloves, such as low-modulus, medical-grade, low-filler, and cleanroom products. This study evaluated the influence of simulated movement on the physical integrity (i.e., holes) of different nitrile exam glove brands and types. Thirty glove products were evaluated out-of-box and after exposure to simulated whole-glove movement for 2 hr. In lieu of the traditional 1-L water-leak test, a modified water-leak test, standardized to detect a 0.15 ± 0.05 mm hole in different regions of the glove, was developed. A specialized air inflation method simulated bidirectional stretching and whole-glove movement. A worst-case scenario with maximum stretching was evaluated. On average, movement did not have a significant effect on glove integrity (chi-square; p=0.068). The average effect was less than 1% between no movement (1.5%) and movement (2.1%) exposures. However, there was significant variability in glove integrity between different glove types (p ≤ 0.05). Cleanroom gloves, on average, had the highest percentage of leaks, and 50% failed the water-leak test. Low-modulus and medical-grade gloves had the lowest percentages of leaks, and no products failed the water-leak test. Variability in polymer formulation was suspected to account for the observed discrepancies, as well as the inability of the traditional 1-L water-leak test to detect holes in finger/thumb regions. Unexpectedly, greater than 80% of the glove defects were observed in the finger and thumb regions. It is recommended that existing water-leak tests be re-evaluated and standardized to account for product variability. PMID:21476169

  6. Decontamination and dismantling of large plutonium-contamined glove boxes

    International Nuclear Information System (INIS)

    Draulans, J.

    1991-01-01

    This report describes the work performed in the frame of two C.E.C. - Contracts FI1D-002400-B Decommissioning of very large glove boxes and FI1D-0058 Decommissioning of a complex glove box structure to be dismounted partially on place. Detailed information is given about each glove box. The selection of the solution Transportation of the glove boxes to a specialized dismantling plant is justified. The necessary contacts inside the BELGONUCLEAIRE MOX plant and between the latter and other organizations are explained. The problems of manipulating large gloves are listed and the retained solution of building a so called Stiffening frame around each glove box is described. Furthermore information is given concerning required operators time for cleaning, manipulating, packing and dismantling together with received doses and quantities of waste produced. Concerning the glove box unit partially to be dismounted on place, detailed information is given about the way the glove boxes have been treated prior to this partial dismantling on place and about the way this partial dismantling has been performed. From these results one can conclude that such a delicate task can be performed without major difficulties. Finally information is given of the decontamination test of a highly Pu contaminated glove box with freon with rather poor results and of the preliminary CO 2 blasting tests on non active samples

  7. Benchmarking Evaluation Results for Prototype Extravehicular Activity Gloves

    Science.gov (United States)

    Aitchison, Lindsay; McFarland, Shane

    2012-01-01

    The Space Suit Assembly (SSA) Development Team at NASA Johnson Space Center has invested heavily in the advancement of rear-entry planetary exploration suit design but largely deferred development of extravehicular activity (EVA) glove designs, and accepted the risk of using the current flight gloves, Phase VI, for unique mission scenarios outside the Space Shuttle and International Space Station (ISS) Program realm of experience. However, as design reference missions mature, the risks of using heritage hardware have highlighted the need for developing robust new glove technologies. To address the technology gap, the NASA Game-Changing Technology group provided start-up funding for the High Performance EVA Glove (HPEG) Project in the spring of 2012. The overarching goal of the HPEG Project is to develop a robust glove design that increases human performance during EVA and creates pathway for future implementation of emergent technologies, with specific aims of increasing pressurized mobility to 60% of barehanded capability, increasing the durability by 100%, and decreasing the potential of gloves to cause injury during use. The HPEG Project focused initial efforts on identifying potential new technologies and benchmarking the performance of current state of the art gloves to identify trends in design and fit leading to establish standards and metrics against which emerging technologies can be assessed at both the component and assembly levels. The first of the benchmarking tests evaluated the quantitative mobility performance and subjective fit of four prototype gloves developed by Flagsuit LLC, Final Frontier Designs, LLC Dover, and David Clark Company as compared to the Phase VI. All of the companies were asked to design and fabricate gloves to the same set of NASA provided hand measurements (which corresponded to a single size of Phase Vi glove) and focus their efforts on improving mobility in the metacarpal phalangeal and carpometacarpal joints. Four test

  8. Durable Tactile Glove for Human or Robot Hand

    Science.gov (United States)

    Butzer, Melissa; Diftler, Myron A.; Huber, Eric

    2010-01-01

    A glove containing force sensors has been built as a prototype of tactile sensor arrays to be worn on human hands and anthropomorphic robot hands. The force sensors of this glove are mounted inside, in protective pockets; as a result of this and other design features, the present glove is more durable than earlier models.

  9. Shielding ability of lead loaded radiation resistant gloves

    International Nuclear Information System (INIS)

    Kawano, Takao; Ebihara, Hiroshi

    1990-01-01

    The shielding ability of radiation resistant gloves were examined. The gloves are made of lead loaded (as PbO 2 ) polyvinyl chloride resin and are about 0.4 mm of thickness (70 mg/cm 2 ). Eleven test pieces were sampled from each of three gloves (total were thirty three) and the transmission rates for radiations (X-ray or γ-ray) through the test pieces were measured with radiation sources, 99m Tc, 57 Co, 133 Ba, 133 Xe and 241 Am. The differences of the transmission rate for radiations by the positions of the gloves were smaller than 15%, and the differences by three gloves were smaller than 5% in the case of 60 keV and 141 keV radiations. The average transmission rates for radiations in thirty three test pieces were about 40% for 30 keV radiation, about 90% for 80 keV and 140 keV radiations. The shielding characteristic of the gloves could be equivalent to about 0.026 mm thick lead plate. (author)

  10. Evaluation of the efficacy of antibacterial medical gloves in the ICU setting.

    Science.gov (United States)

    Kahar Bador, M; Rai, V; Yusof, M Y; Kwong, W K; Assadian, O

    2015-07-01

    Inappropriate use of medical gloves may support microbial transmission. New strategies could increase the safety of medical gloves without the risk of patient and surface contamination. To compare the efficacy of synthetic antibacterial nitrile medical gloves coated with polyhexamethylen-biguanid hydrochloride (PHMB) on the external surface with identical non-antibacterial medical gloves in reducing glove contamination after common patient care measures in an intensive care unit (ICU) setting. ICU staff wore either standard or antibacterial gloves during patient care activities. The number of bacteria on gloves was measured semi-quantitatively immediately after the performance of four clinical activities. There was a significant difference in mean bacterial growth [colony-forming units (cfu)] between control gloves and antibacterial gloves {60 [standard deviation (SD) 23] vs 16 (SD 23) cfu/glove imprint, P gloves had significantly less bacterial contamination compared with the control gloves (P = 0.011 and gloves showed lower bacterial contamination after changing linen compared with control gloves, the difference was not significant (P = 0.311). This study showed that use of antibacterial medical gloves significantly reduced bacterial contamination after typical patient care activities in 57% of the investigated clinical activities (P gloves may support reduction of cross-contamination in the ICU setting. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  11. High Performance EVA Glove Collaboration: Glove Injury Data Mining Effort

    Science.gov (United States)

    Reid, C. R.; Benosn, E.; England, S.; Norcross, J. R.; McFarland, S. M.; Rajulu, S.

    2014-01-01

    Human hands play a significant role during extravehicular activity (EVA) missions and Neutral Buoyancy Lab (NBL) training events, as they are needed for translating and performing tasks in the weightless environment. It is because of this high frequency usage that hand- and arm-related injuries and discomfort are known to occur during training in the NBL and while conducting EVAs. Hand-related injuries and discomforts have been occurring to crewmembers since the days of Apollo. While there have been numerous engineering changes to the glove design, hand-related issues still persist. The primary objectives of this study are therefore to: 1) document all known EVA glove-related injuries and the circumstances of these incidents, 2) determine likely risk factors, and 3) recommend ergonomic mitigations or design strategies that can be implemented in the current and future glove designs. METHODS: The investigator team conducted an initial set of literature reviews, data mining of Lifetime Surveillance of Astronaut Health (LSAH) databases, and data distribution analyses to understand the ergonomic issues related to glove-related injuries and discomforts. The investigation focused on the injuries and discomforts of U.S. crewmembers who had worn pressurized suits and experienced glove-related incidents during the 1980 to 2010 time frame, either during training or on-orbit EVA. In addition to data mining of the LSAH database, the other objective of the study was to find complimentary sources of information such as training experience, EVA experience, suit-related sizing data, and hand-arm anthropometric data to be tied to the injury data from LSAH. RESULTS: Past studies indicated that the hand was the most frequently injured part of the body during both EVA and NBL training. This study effort thus focused primarily on crew training data in the NBL between 2002 and 2010. Of the 87 recorded training incidents, 19 occurred to women and 68 to men. While crew ages ranged from

  12. Transmission of vibration through gloves: effects of contact area.

    Science.gov (United States)

    Md Rezali, Khairil Anas; Griffin, Michael J

    2017-01-01

    For three samples of material (12.5, 25.0 and 37.5 mm diameter) from each of three gloves, the dynamic stiffnesses and the vibration transmissibilities of the materials (to both the palm of the hand and the thenar eminence) were measured at frequencies from 10 to 300 Hz. Additional measurements showed the apparent masses of the hand at the palm and the thenar eminence were independent of contact area at frequencies less than about 40 Hz, but increased with increasing area at higher frequencies. The stiffness and damping of the glove materials increased with increasing area. These changes caused material transmissibilities to the hand to increase with increasing area. It is concluded that the size of the area of contact has a large influence on the transmission of vibration through a glove to the hand. The area of contact should be well-defined and controlled when evaluating the transmission of vibration through gloves. Practitioner Summary: The transmission of vibration through gloves depends on both the dynamic stiffness of glove material and the dynamic response of the hand. Both of these depend on the size of the contact area between a glove material and the hand, which should be taken into account when assessing glove transmissibility.

  13. A review of the materials and allergens in protective gloves.

    Science.gov (United States)

    Rose, Rebecca F; Lyons, Paul; Horne, Helen; Mark Wilkinson, S

    2009-09-01

    The ingredients previously reported to cause protective glove allergy are presented and evaluated for strength of evidence. Allergens that have caused both delayed hypersensitivity and contact urticaria are considered for rubber, plastic, leather, and textile gloves. The current guidelines regarding glove manufacture are described. A list of materials confirmed by the industry to be used in glove production is presented together with a suggested series for investigating patients with delayed type hypersensitivity and contact urticaria secondary to glove use.

  14. Electrical requirements for unshielded glove boxes

    International Nuclear Information System (INIS)

    1978-02-01

    The specification relates to the general design and installation of electrical services required in unshielded glove boxes in which atmospheres of air, argon or nitrogen etc. may exist either temporarily or permanently. The specification does not apply to electrical services for glove boxes with flammable explosive atmospheres. (author)

  15. New approaches to glove box design at Hanford

    International Nuclear Information System (INIS)

    Lini, D.C.; Fisher, F.D.; Walters, F.F.

    1986-01-01

    Glove boxes provide the primary environmental containment system for plutonium processing operations at US Dept. of Energy (DOE)-owned facilities such as Rockwell Hanford. As noted in previous presentations, glove box designs and operations have evolved through stages that are a result of advances in processing techniques, new regulatory requirements, and cost escalation. These factors will continue to influence the current glove box designs and operations. The purpose of this presentation is to discuss required upgrades and changes that are being incorporated into glove boxes being installed at Rockwell Hanford and other DOE installations or are being evaluated for future upgrades

  16. Thermal comfort of dual-chamber ski gloves

    Science.gov (United States)

    Dotti, F.; Colonna, M.; Ferri, A.

    2017-10-01

    In this work, the special design of a pair of ski gloves has been assessed in terms of thermal comfort. The glove 2in1 Gore-Tex has a dual-chamber construction, with two possible wearing configurations: one called “grip” to maximize finger flexibility and one called “warm” to maximize thermal insulation in extremely cold conditions. The dual-chamber gloves has been compared with two regular ski gloves produced by the same company. An intermittent test on a treadmill was carried out in a climatic chamber: it was made of four intense activity phases, during which the volunteer ran at 9 km/h on a 5% slope for 4 minutes, spaced out by 5-min resting phases. Finger temperature measurements were compared with the thermal sensations expressed by two volunteers during the test.

  17. Safety of the surgeon: 'Double-gloving' during surgical procedures

    African Journals Online (AJOL)

    during exposure to blood and body fluids are now mandatory. Intact surgical gloves can ... HIV/AIDS infection is for the surgeon to 'double-glove' – wear two standard gloves on .... sharp fractured bones or bony structures.[12,16,17] The rate of ...

  18. Evaluating Utility Gloves as a Potential Reservoir for Pathogenic Bacteria.

    Science.gov (United States)

    Grant, Kathy L; Naber, E Donald; Halteman, William A

    2015-08-01

    This pilot study sought to determine the rate and degree to which gram-negative Klebsiella pneumoniae, Escherichia coli and Pseudomonas aeruginosa and gram-positive Staphylococcus aureus occurred on the inside of utility gloves used at University of Maine at Augusta, Dental Health Programs' dental hygiene clinic. Five steam autoclave utility gloves were randomly selected to serve as control and a convenience sample of 10 used utility gloves were selected from the sterilization area. A sample was collected from a predetermined surface area from the inside of each steam autoclave utility glove and used utility glove. Each sample was used to inoculate a Petri plate containing 2 types of culture media. Samples were incubated at 37° C for 30 to 36 hours in aerobic conditions. Colony forming units (CFU) were counted. Confidence intervals (CI) estimated the rate of contamination with gram-negative K. pneumoniae, E. coli and P. aeruginosa on the inside of steam autoclave utility gloves to be n=33 95% CL [0.000, 0.049], used utility gloves to be n=70, 95% CL [0.000, 0.0303]. Data estimated the rate of contamination with gram-positive S. aureus on the inside of steam autoclave utility gloves to be n=35, 95% CL [0.233, 0.530], used utility gloves to be n=70, 95% CL [0.2730, 0.4975]. Culture media expressed a wide range of CFU from 0 to over 200. The risk of utility glove contamination with gram-negative bacteria is likely low. The expressed growth of S. aureus from steam autoclave utility gloves controls raises questions about the effectiveness and safety of generally accepted sterilization standards for the governmentally mandated use of utility gloves. Copyright © 2015 The American Dental Hygienists’ Association.

  19. Design options for improving protective gloves for industrial assembly work.

    Science.gov (United States)

    Dianat, Iman; Haslegrave, Christine M; Stedmon, Alex W

    2014-07-01

    The study investigated the effects of wearing two new designs of cotton glove on several hand performance capabilities and compared them against the effects of barehanded, single-layered and double cotton glove conditions when working with hand tools (screwdriver and pliers). The new glove designs were based on the findings of subjective hand discomfort assessments for this type of work and aimed to match the glove thickness to the localised pressure and sensitivity in different areas of the hand as well as to provide adequate dexterity for fine manipulative tasks. The results showed that the first prototype glove and the barehanded condition were comparable and provided better dexterity and higher handgrip strength than double thickness gloves. The results support the hypothesis that selective thickness in different areas of the hand could be applied by glove manufacturers to improve the glove design, so that it can protect the hands from the environment and at the same time allow optimal hand performance capabilities. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  20. Light transmission and air used for inspection of glovebox gloves

    International Nuclear Information System (INIS)

    Castro, Julio M.; Steckle, Warren P. Jr.; Macdonald, John M.

    2002-01-01

    Various materials used for manufacturing the glovebox gloves are translucent material such as hypalon, rubbers, and neoprene. This means that visible light can be transmitted through the inside of the material. Performing this test can help to increase visualization of the integrity of the glove. Certain flaws such as pockmarks, foreign material, pinholes, and scratches could be detected with increased accuracy. An analysis was conducted of the glovebox gloves obscure polymer material using a inspection light table. The fixture is equipped with a central light supply and small air pump to inflate the glove and test for leak and stability. A glove is affixed to the fixture for 360-degree inspection. Certain inspection processes can be performed: (1) Inspection for pockmarks and thin areas within the gloves; (2) Observation of foreign material within the polymer matrix; and (3) Measurements could be taken for gloves thickness using light measurements. This process could help reduce eyestrain when examining gloves and making a judgment call on the size of material thickness in some critical areas. Critical areas are fingertips and crotch of fingers.

  1. Determination of skin dose reduction by lead equivalent gloves

    International Nuclear Information System (INIS)

    Norriza Mohd Isa; Abd Aziz Mhd Ramli

    2006-01-01

    Radiation protective gloves are always used in medical facilities to protect radiation workers from unnecessary radiation exposure. A study on radiation protection gloves which are produced by local company had been performed by the Medical Physics Group, MINT. The gloves were made of lead equivalent material, as the attenuating element. The gloves were evaluated in term of the percentage of skin dose reduction by using a newly developed procedure and facilities in MINT. Attenuation measurements of the gloves had been carried out using direct beams and scattered radiations of different qualities. TLD rings were fitted on finger phantom; and water phantom were used in the measurement. The result were obtained and analysed based on data supplied by manufacturer. (Author)

  2. Glove failure in elective thyroid surgery: A prospective randomized study

    Directory of Open Access Journals (Sweden)

    Dariusz Timler

    2015-06-01

    Full Text Available Objectives: To analyze perforation rate in sterile gloves used by surgeons in the operating theatre of the Department of Endocrinological and General Surgery of Medical University of Lodz. Material and Methods: Randomized and controlled trial. This study analyses the incidents of tears in sterile surgical gloves used by surgeons during operations on 3 types of thyroid diseases according to the 10th revision of International Statistical Classification of Diseases and Related Health Problems (ICD-10 codes. Nine hundred seventy-two pairs (sets of gloves were collected from 321 surgical procedures. All gloves were tested immediately following surgery using the water leak test (EN455-1 to detect leakage. Results: Glove perforation was detected in 89 of 972 glove sets (9.2%. Statistically relevant more often glove tears occurred in operator than the 1st assistant (p < 0.001. The sites of perforation were localized mostly on the middle finger of the non-dominant hand (22.5%, and the non-dominant ring finger (17.9%. Conclusions: This study has proved that the role performed by the surgeon during the procedure (operator, 1st assistant has significant influence on the risk of glove perforations. Nearly 90% of glove perforations are unnoticed during surgery.

  3. Prospective randomized assessment of single versus double-gloving for general surgical procedures.

    Science.gov (United States)

    Na'aya, H U; Madziga, A G; Eni, U E

    2009-01-01

    There is increased tendency towards double-gloving by general surgeons in our practice, due probably to awareness of the risk of contamination with blood or other body fluids during surgery. The aim of the study was to compare the relative frequency of glove puncture in single-glove versus double glove sets in general surgical procedures, and to determine if duration of surgery affects perforation rate. Surgeons at random do single or double gloves at their discretion, for general surgical procedures. All the gloves used by the surgeons were assessed immediately after surgery for perforation. A total of 1120 gloves were tested, of which 880 were double-glove sets and 240 single-glove sets. There was no significant difference in the overall perforation rate between single and double glove sets (18.3% versus 20%). However, only 2.3% had perforations in both the outer and inner gloves in the double glove group. Therefore, there was significantly greater risk for blood-skin exposure in the single glove sets (p < 0.01). The perforation rate was also significantly greater during procedures lasting an hour or more compared to those lasting less than an hour (p < 0.01). Double-gloving reduces the risk of blood-skin contamination in all general surgical procedures, and especially so in procedures lasting an hour or more.

  4. Air-tighten test for used glove boxes

    International Nuclear Information System (INIS)

    Itoh, Masanori; Kashiro, Kashio; Matsumoto, Masaki; Ogiya, Takashi; Nakata, Keiji; Gohda, Masahiko

    2000-05-01

    All of the glove boxes in Plutonium Fuel Fabrication facilities are operated after confirming their condition by conducting negative pressure maintenance test and air-tighten test. Although we check the negative pressure maintenance condition before operating glove boxes in a daily basis, we have not been conducted the air-tighten test. Hence, we have conduct air-tighten test using the glove box that will be dismantled in the near future. In order to compare the present data to the criteria of licensing and to the measurement data for new glove box, the test was conducted by leak tightness vessel which is used the competent authority's test for newly constructed equipments. We also have confirmed the leakage condition in case failure of keeping negative pressure. The main results are as follows: 1. No leakage was detected after leaving the glove box 21 days in case failure of keeping negative pressure condition. 2. The measurement result of the air-tighten test was 0.025 vol%/h, and it was confirmed that this result is within the range of licensing criteria (-0.04 - 0.06 vol%/h). 3. The measurement result was also within the error of leak tightness vessel, and it was confirmed that the air-tighten condition was in force within this past 10 years after installing this glove box (the corresponding value for used the competent authority test for newly constructed equipments was 0.019 vol%/h). (author)

  5. Design report for shielded glove box

    International Nuclear Information System (INIS)

    Ku, J. H.; Lee, J. C.; Seo, K. S.; Bang, K. S.; Lee, D. W.; Kim, J. H.; Min, D. K.; Park, S. W.

    1999-05-01

    For the examination of spent fuels and high radioactive specimens using a specially equipped scanning electron microscope, a shielded glove box was designed and constructed at PIE facility of KAERI. This glove box consisted of shielding walls, containment box, lead glasses, manipulators, gloves, ventilation systems, doors, hot-cell specimen cask adapter, etc. It was emphasized that both the easy operation and radiation safety are important factors in the shielded glove box were installed also considered as a important factor to build the basic concept of the assembling. Two sliding doors and one hinge-type door were installed for the easy installation, operation and maintenance of scanning electron microscope. Containment box which confines the radioactive material into the box consisted of reinforced transparent glasses, aluminum frames and stainless steel plate liner. Therefore everything beyond the containment box can be seen through the lead glass which installed at the front shielding wall. All shielding walls and doors were introduced separately into the room and assembled by bolting. (author). 3 refs., 5 tabs., 18 figs

  6. Fundamentals of the knowledge about chemical additives present in rubber gloves.

    Science.gov (United States)

    Oliveira, Hegles Rosa de; Alchorne, Alice de Oliveira de Avelar

    2011-01-01

    One of the most frequent causes of allergic contact dermatitis of occupational origin are rubber additives, which are present in Personal Protective Equipment (PPE). The most allergenic additives of natural and synthetic gloves are thiurams, carbamates and mercapto group. To investigate the state of knowledge about the chemical additives used in the manufacture of synthetic rubber gloves. This was a qualitative research study in which professionals working in the manufacture, research, prescription and commercialization of gloves answered an open questionnaire. 30 individuals were interviewed: 4 researchers in occupational medicine, 5 occupational physicians, 2 occupational safety technicians, a rubber workers' union physician, an occupational safety engineer, a pro duction engineer of rubber gloves, 4 importers of gloves, a manufacturer of gloves, 3 businessmen who sell PPE, 3 salesclerks working in stores that sell PPE, 2 businessmen who own stores that sell products for allergic individuals, and 3 dermatologists. Knowledge of the chemical composition of rubber gloves is scant. The labeling of gloves, with the description of their chemical composition, would facilitate choosing the best type of glove for each person. This low-cost action to businesses would be a gain from the standpoint of public health, with huge repercussions for users of rubber gloves.

  7. An Approach for Performance Assessments of Extravehicular Activity Gloves

    Science.gov (United States)

    Aitchison, Lindsay; Benosn, Elizabeth

    2014-01-01

    The Space Suit Assembly (SSA) Development Team at NASA Johnson Space Center has invested heavily in the advancement of rear-entry planetary exploration suit design but largely deferred development of extravehicular activity (EVA) glove designs, and accepted the risk of using the current flight gloves, Phase VI, for unique mission scenarios outside the Space Shuttle and International Space Station (ISS) Program realm of experience. However, as design reference missions mature, the risks of using heritage hardware have highlighted the need for developing robust new glove technologies. To address the technology gap, the NASA Game-Changing Technology group provided start-up funding for the High Performance EVA Glove (HPEG) Project in the spring of 2012. The overarching goal of the HPEG Project is to develop a robust glove design that increases human performance during EVA and creates pathway for future implementation of emergent technologies, with specific aims of increasing pressurized mobility to 60% of barehanded capability, increasing the durability by 100%, and decreasing the potential of gloves to cause injury during use. The HPEG Project focused initial efforts on identifying potential new technologies and benchmarking the performance of current state of the art gloves to identify trends in design and fit leading to establish standards and metrics against which emerging technologies can be assessed at both the component and assembly levels. The first of the benchmarking tests evaluated the quantitative mobility performance and subjective fit of two sets of prototype EVA gloves developed ILC Dover and David Clark Company as compared to the Phase VI. Both companies were asked to design and fabricate gloves to the same set of NASA provided hand measurements (which corresponded to a single size of Phase Vi glove) and focus their efforts on improving mobility in the metacarpal phalangeal and carpometacarpal joints. Four test subjects representing the design-to hand

  8. Tactile Gloves for Autonomous Grasping With the NASA/DARPA Robonaut

    Science.gov (United States)

    Martin, T. B.; Ambrose, R. O.; Diftler, M. A.; Platt, R., Jr.; Butzer, M. J.

    2004-01-01

    Tactile data from rugged gloves are providing the foundation for developing autonomous grasping skills for the NASA/DARPA Robonaut, a dexterous humanoid robot. These custom gloves compliment the human like dexterity available in the Robonaut hands. Multiple versions of the gloves are discussed, showing a progression in using advanced materials and construction techniques to enhance sensitivity and overall sensor coverage. The force data provided by the gloves can be used to improve dexterous, tool and power grasping primitives. Experiments with the latest gloves focus on the use of tools, specifically a power drill used to approximate an astronaut's torque tool.

  9. Permeability of different types of medical protective gloves to acrylic monomers.

    Science.gov (United States)

    Lönnroth, Emma-Christin; Wellendorf, Hanne; Ruyter, Eystein

    2003-10-01

    Dental personnel and orthopedic surgeons are at risk when manually handling products containing methyl methacrylate (MMA). Dental products may also contain cross-linking agents such as ethylene glycol dimethacrylate (EGDMA) or 1,4-butanediol dimethacrylate (1,4-BDMA). Skin contact with monomers can cause hand eczema, and the protection given by gloves manufactured from different types of material is not well known. The aim of this study was to determine the breakthrough time (BTT, min) as a measure of protection (according to the EU standard EN-374-3) for a mixture consisting of MMA, EGDMA and 1,4-BDMA. Fifteen different gloves representing natural rubber latex material, synthetic rubber material (e.g. nitrile rubbers), and synthetic polymer material were tested. The smallest monomer MMA permeated within 3 min through all glove materials. A polyethylene examination glove provided the longest protection period to EGDMA and 1, 4-BDMA (> 120 min and 25.0 min), followed by the surgical glove Tactylon (6.0 min and 8.7 min) and the nitrile glove Nitra Touch (5.0 min and 8.7 min). This study showed that the breakthrough time (based on permeation rate) cannot be regarded as a 'safe limit'. When the permeation rate is low, monomers may have permeated before BTT can be determined. Using double gloves with a synthetic rubber inner glove and a natural rubber outer glove provided longer protection when the inner glove was rinsed in water before placing the outer glove on top.

  10. Dexterity Test Data Contribute To Reduction in Leaded Glovebox Glove Use

    International Nuclear Information System (INIS)

    Cournoyer, M.E.; Lawton, C.M.; Castro, A.M.; Costigan, S.A.; Schreiber, S.

    2009-01-01

    Programmatic operations at the Los Alamos National Laboratory Plutonium Facility (TA-55) involve working with various amounts of plutonium and other highly toxic, alpha-emitting materials. The spread of radiological contamination on surfaces, airborne contamination, and excursions of contaminants into the operator's breathing zone are prevented through the use of a variety of gloveboxes. Using an integrated approach, controls have been developed and implemented through an efficient Glovebox Glove Integrity Program. A key element of this program is to consider measures that lower the overall risk of glovebox operations. Line management who own glovebox processes through this program make decisions on which type of glovebox gloves (hereafter referred to as gloves), the weakest component of this safety-significant system, would perform best in these aggressive environments. As Low as Reasonably Achievable considerations must be balanced with glove durability and worker dexterity, both of which affect the final overall risk of the operation. In the past, lead-loaded (leaded) gloves made from Hypalon R were the primary glove for programmatic operations at TA-55. Replacing leaded gloves with unleaded gloves for certain operations would lower the overall risk as well as reduce the amount of mixed transuranic waste. This effort contributes to the Los Alamos National Laboratory Continuous Improvement Program by improving the efficiency, cost-effectiveness, and formality of glovebox operations. In this report, the pros and cons of wearing leaded gloves, the effect of leaded gloves versus unleaded gloves on task performance using standard dexterity tests, the justification for switching from leaded to unleaded gloves, and the pollution prevention benefits of this dramatic change in the glovebox system are presented. (authors)

  11. Computational Optimization of a Natural Laminar Flow Experimental Wing Glove

    Science.gov (United States)

    Hartshom, Fletcher

    2012-01-01

    Computational optimization of a natural laminar flow experimental wing glove that is mounted on a business jet is presented and discussed. The process of designing a laminar flow wing glove starts with creating a two-dimensional optimized airfoil and then lofting it into a three-dimensional wing glove section. The airfoil design process does not consider the three dimensional flow effects such as cross flow due wing sweep as well as engine and body interference. Therefore, once an initial glove geometry is created from the airfoil, the three dimensional wing glove has to be optimized to ensure that the desired extent of laminar flow is maintained over the entire glove. TRANAIR, a non-linear full potential solver with a coupled boundary layer code was used as the main tool in the design and optimization process of the three-dimensional glove shape. The optimization process uses the Class-Shape-Transformation method to perturb the geometry with geometric constraints that allow for a 2-in clearance from the main wing. The three-dimensional glove shape was optimized with the objective of having a spanwise uniform pressure distribution that matches the optimized two-dimensional pressure distribution as closely as possible. Results show that with the appropriate inputs, the optimizer is able to match the two dimensional pressure distributions practically across the entire span of the wing glove. This allows for the experiment to have a much higher probability of having a large extent of natural laminar flow in flight.

  12. Influence of wearing latex gloves on electric pulp tester readings in children.

    Science.gov (United States)

    Holan, G

    1993-12-01

    Electric pulp testers operated by completing an electric circuit. Latex examination gloves have been claimed to interrupt this circuit and lead to false-negative results. This study was conducted to evaluate the influence of wearing latex gloves on electric pulp tester (EPT) readings. The pulps of 80 maxillary permanent incisors of 22 children 10-13 1/2 years old were tested using the Pelton & Crane 'Vitapulp' instrument. Each tooth was tested twice: with gloves and with bare hands. Teeth failing to respond to the EPT without gloves were excluded from the study. All EPT readings ranged between 1 and 9.5. Five teeth gave the same responses with gloved and ungloved hands. Only five teeth did not respond when gloves were worn, and all of these gave readings near the top of the EPT scale when tested without gloves. The other 70 teeth presented significantly higher readings with gloves than without gloves. It is concluded that removal of examination gloves during the operation of the EPT is necessary only if no response is obtained.

  13. Closure of an analytical chemistry glove box in alpha laboratory

    International Nuclear Information System (INIS)

    Adelfang, P.; Aparicio, G.; Cassaniti, P.

    1990-01-01

    The works with plutonium are performed in gloves box, operated below atmospheric pressure, to protect the experimenters from this alpha-active material. After 12 years of continual processes, it was necessary the decommissioning of the chemistry glove box in our alpha-laboratory. A great deal of our attention was devoted to the working techniques because of extreme care needed to avoid activity release. The decommissioning includes the following main operations: a) Planning and documentation for the regulatory authority. b) Internal decontamination with surface cleaning and chelating agents. c) Measurement of the remainder internal radioactivity. d) Sealing of the glove ports and nozzles. e) Disconnection of the glove box from the exhaust duct. f) Design and construction of a container for the glove box. g) Transportation of the glove box from alpha-laboratory, to a transitory storage until its final disposal. The above mentioned operations are described in this paper including too: data of personal doses during the operations, characteristics and volumes of radioactive wastes and a description of the instrument used for the measurement of inside glove box activity. (Author) [es

  14. Earthquake resistance test of full-scale glove box

    International Nuclear Information System (INIS)

    Fujita, T.; Ohtani, K.; Hayashi, M.; Kozeki, M.; Ide, T.; Sakuno, K.

    1989-01-01

    A glove box used at nuclear facilities must confine radioactive materials. High airtightness and negative internal pressure are used to prevent leaks. The allowable leakage rate of air is 0.1% vol/hr or less at the pre-service inspection. The negative pressure value is kept at - 30 mm H 2 O in normal operation. The glove box structural strength and its confinement reliability during an earthquake are major concerns. The verification of aseismic analysis methods and assumptions for a glove box are thus of great importance. Data on the dynamic behavior of giant glove boxes was recently obtained in large shaker experiments. This paper describes these experimental results and the appropriateness of aseismic analysis methods used in current design

  15. EVA Glove Research Team

    Science.gov (United States)

    Strauss, Alvin M.; Peterson, Steven W.; Main, John A.; Dickenson, Rueben D.; Shields, Bobby L.; Lorenz, Christine H.

    1992-01-01

    The goal of the basic research portion of the extravehicular activity (EVA) glove research program is to gain a greater understanding of the kinematics of the hand, the characteristics of the pressurized EVA glove, and the interaction of the two. Examination of the literature showed that there existed no acceptable, non-invasive method of obtaining accurate biomechanical data on the hand. For this reason a project was initiated to develop magnetic resonance imaging as a tool for biomechanical data acquisition and visualization. Literature reviews also revealed a lack of practical modeling methods for fabric structures, so a basic science research program was also initiated in this area.

  16. Tool-specific performance of vibration-reducing gloves for attenuating fingers-transmitted vibration

    Science.gov (United States)

    Welcome, Daniel E.; Dong, Ren G.; Xu, Xueyan S.; Warren, Christopher; McDowell, Thomas W.

    2016-01-01

    BACKGROUND Fingers-transmitted vibration can cause vibration-induced white finger. The effectiveness of vibration-reducing (VR) gloves for reducing hand transmitted vibration to the fingers has not been sufficiently examined. OBJECTIVE The objective of this study is to examine tool-specific performance of VR gloves for reducing finger-transmitted vibrations in three orthogonal directions (3D) from powered hand tools. METHODS A transfer function method was used to estimate the tool-specific effectiveness of four typical VR gloves. The transfer functions of the VR glove fingers in three directions were either measured in this study or during a previous study using a 3D laser vibrometer. More than seventy vibration spectra of various tools or machines were used in the estimations. RESULTS When assessed based on frequency-weighted acceleration, the gloves provided little vibration reduction. In some cases, the gloves amplified the vibration by more than 10%, especially the neoprene glove. However, the neoprene glove did the best when the assessment was based on unweighted acceleration. The neoprene glove was able to reduce the vibration by 10% or more of the unweighted vibration for 27 out of the 79 tools. If the dominant vibration of a tool handle or workpiece was in the shear direction relative to the fingers, as observed in the operation of needle scalers, hammer chisels, and bucking bars, the gloves did not reduce the vibration but increased it. CONCLUSIONS This study confirmed that the effectiveness for reducing vibration varied with the gloves and the vibration reduction of each glove depended on tool, vibration direction to the fingers, and finger location. VR gloves, including certified anti-vibration gloves do not provide much vibration reduction when judged based on frequency-weighted acceleration. However, some of the VR gloves can provide more than 10% reduction of the unweighted vibration for some tools or workpieces. Tools and gloves can be matched for

  17. 21 CFR 800.20 - Patient examination gloves and surgeons' gloves; sample plans and test method for leakage defects...

    Science.gov (United States)

    2010-04-01

    ... examination and by a water leak test method, using 1,000 milliliters (ml) of water. (i) Units examined. Each... inches up the fill tube.) (iii) Leak test examination. Immediately after adding the water, examine the glove for water leaks. Do not squeeze the glove; use only minimum manipulation to spread the fingers to...

  18. Efficacy of protection by latex gloves during orthodontic therapy.

    Science.gov (United States)

    Doll, G M; Zentner, A; Balan, R; Sergl, H G

    2000-01-01

    The wearing of gloves during orthodontic or dental treatment is generally indicated for reasons of hygiene and protection against infection. This study was aimed at determining the extent and localization of perforations caused by the various orthodontic treatment techniques and interrupting the infection barrier. The impermeability was tested by means of a water retention test according to European standard EN 455, Part 1, performed on 1600 Centramed (Centramed, Koblenz), Tekmedic and SafeEx non-sterile disposable latex gloves (both by Safe Med, Switzerland) and Safe Gan latex gloves with an additional acrylate coating (also by Safe Med). The perforation rate in unused gloves was between 0.5% and 7.5%, rising on average to 11% with increasing use. 36% of the total number of lesions resulted from handling removable appliances, and 57% from handling fixed appliances, especially when replacing arch wires and elastics. Most lesions were in the thumb, index finger and palm region. Only 18% of the defects were noticed by the dentists themselves. The gloves worn by beginners in their first year of postgraduate orthodontic training had about twice as many defects as those worn by qualified orthodontists. When patients with an increased risk of infection are to be treated, additional hand disinfection measures should be taken and 2 pairs of gloves worn in view of the relatively unreliable protection offered by commercially available latex gloves.

  19. Development of Wireless RFID Glove for Various Applications

    Science.gov (United States)

    Lee, Changwon; Kim, Minchul; Park, Jinwoo; Oh, Jeonghoon; Eom, Kihwan

    Radio Frequency Identification is increasingly popular technology with many applications. The majority of applications of RFID are supply-chain management. In this paper, we proposed the development of wireless RFID Glove for various applications in real life. Proposed wireless RFID glove is composed of RFID reader of 13.56 MHz and RF wireless module. Proposed Gloves were applied to two applications. First is the interactive leaning and second is Meal aid system for blind people. The experimental results confirmed good performances.

  20. Ballast system for maintaining constant pressure in a glove box

    Science.gov (United States)

    Shlichta, Paul J.

    1989-09-01

    A ballast system is disclosed for a glove box including a fixed platform on which is mounted an inflatable bag on top of which resides a cover and a weight. The variable gas volume of the inflatable bag communicates with that of the glove box via a valved tube. The weight and the gas volume are selected to maintain a relatively constant pressure in the glove box despite variations in the glove box volume while avoiding the use of complicated valving apparatus.

  1. Will medical examination gloves protect rescuers from defibrillation voltages during hands-on defibrillation?

    Science.gov (United States)

    Sullivan, Joseph L; Chapman, Fred W

    2012-12-01

    Continuing compressions during a defibrillation shock has been proposed as a method of reducing pauses in cardiopulmonary resuscitation (CPR) but the safety of this procedure is unproven. The medical examination gloves worn by rescuers play an important role in protecting the rescuer yet the electrical characteristics of these gloves are unknown. This study examined the response of medical examination gloves to defibrillation voltages. Part 1 of this study measured voltage-current curves for a small sample (8) of gloves. Part 2 tested more gloves (460) to determine the voltage required to produce a specific amount of current flow. Gloves were tested at two current levels: 0.1 mA and 10 mA. Testing included four glove materials (chloroprene, latex, nitrile, and vinyl) in a single layer and double-gloved. All gloves tested in part 1 allowed little current to flow (gloves and 93 of 120 (77%) double gloves allowed at least 0.1 mA of current flow at voltages within the external defibrillation voltage range. Also, 6 of 80 (7.5%) single gloves and 5 of 80 (6.2%) double gloves allowed over 10 mA. Few of the gloves tested limited the current to levels proven to be safe. A lack of sensation during hands-on defibrillation does not guarantee that a safety margin exists. As such, we encourage rescuers to minimize rather than eliminate the pause in compressions for defibrillation. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  2. Comparing the level of dexterity offered by latex and nitrile SafeSkin gloves.

    Science.gov (United States)

    Sawyer, Jo; Bennett, Allan

    2006-04-01

    An increase in the occurrence of latex allergy has been concurrent with the increasing use of latex gloves by laboratory and healthcare workers. In recent years nitrile gloves have been used to replace latex gloves to prevent latex allergy. Nitrile gloves offer a comparable level of protection against chemical and biological agents and are more puncture resistant. However, if manual dexterity is compromised by nitrile gloves to a greater degree than latex then this may increase the risk of sharps injuries. The Purdue pegboard test, which measures both gross and fine finger dexterity, was used to test the dexterity levels of two glove types used at HPA CEPR; Kimberly-Clark SafeSkin nitrile and latex laboratory gloves. There was a statistically significant 8.6% increase in fine finger dexterity provided by latex compared with nitrile SafeSkin laboratory gloves but no difference in gross dexterity between the glove types. There was no significant relationship between glove dexterity and age or gender. The selection of glove size was influenced by the digit length of participants. Moreover, those with longer, thinner fingers appeared to have an advantage when using nitrile SafeSkin gloves. The level of dexterity provided by latex and nitrile SafeSkin gloves for tasks on a gross dexterity level are comparable and health workers will benefit from the non-allergenic properties of nitrile. For tasks requiring fine finger dexterity nitrile SafeSkin gloves may impede dexterity. Despite this, the degree of restriction appears to have a negligible impact on safety in this study when compared with the risk of latex sensitization and subsequent allergy. In addition to glove material, working practices must also take into account glove size, fit, grip and thickness, as these factors can all influence dexterity.

  3. An MCNP model of glove boxes in a plutonium processing facility

    International Nuclear Information System (INIS)

    Dooley, D.E.; Kornreich, D.E.

    1998-01-01

    Nuclear material processing usually occurs simultaneously in several glove boxes whose primary purpose is to contain radioactive materials and prevent inhalation or ingestion of radioactive materials by workers. A room in the plutonium facility at Los Alamos National Laboratory has been slated for installation of a glove box for storing plutonium metal in various shapes during processing. This storage glove box will be located in a room containing other glove boxes used daily by workers processing plutonium parts. An MCNP model of the room and glove boxes has been constructed to estimate the neutron flux at various locations in the room for two different locations of the storage glove box and to determine the effect of placing polyethylene shielding around the storage glove box. A neutron dose survey of the room with sources dispersed as during normal production operations was used as a benchmark to compare the neutron dose equivalent rates calculated by the MCNP model

  4. Novel Smart Glove Technology as a Biomechanical Monitoring Tool

    Directory of Open Access Journals (Sweden)

    Brendan O’FLYNN

    2015-10-01

    Full Text Available Developments in Virtual Reality (VR technology and its overall market have been occurring since the 1960s when Ivan Sutherland created the world’s first tracked head-mounted display (HMD – a goggle type head gear. In society today, consumers are expecting a more immersive experience and associated tools to bridge the cyber-physical divide. This paper presents the development of a next generation smart glove microsystem to facilitate Human Computer Interaction through the integration of sensors, processors and wireless technology. The objective of the glove is to measure the range of hand joint movements, in real time and empirically in a quantitative manner. This includes accurate measurement of flexion, extension, adduction and abduction of the metacarpophalangeal (MCP, Proximal interphalangeal (PIP and Distal interphalangeal (DIP joints of the fingers and thumb in degrees, together with thumb-index web space movement. This system enables full real-time monitoring of complex hand movements. Commercially available gloves are not fitted with sufficient sensors for full data capture, and require calibration for each glove wearer. Unlike these current state-of-the-art data gloves, the UU / Tyndall Inertial Measurement Unit (IMU glove uses a combination of novel stretchable substrate material and 9 degree of freedom (DOF inertial sensors in conjunction with complex data analytics to detect joint movement. Our novel IMU data glove requires minimal calibration and is therefore particularly suited to multiple application domains such as Human Computer interfacing, Virtual reality, the healthcare environment..

  5. Understanding Factors that Influence Protective Glove Use among Automotive Spray Painters

    Science.gov (United States)

    Ceballos, Diana; Reeb-Whitaker, Carolyn; Glazer, Patricia; Murphy-Robinson, Helen; Yost, Michael

    2017-01-01

    Dermal contact with isocyanate-based coatings may lead to systemic respiratory sensitization. The most common isocyanates found in sprayed automotive coatings are monomeric and oligomeric 1,6-hexamethylene diisocyanate (HDI) and isophorone diisocyanate (IPDI). Most spray painters use thin (4–5 mil) latex gloves that are not effective at preventing dermal exposures when spraying isocyanate paints. Personal interviews with collision repair industry personnel and focus groups with spray painters were held to characterize risk awareness, to examine perceptions and challenges concerning protective glove use and selection, and to generate ideas for protective glove use interventions. The most popular gloves among spray painters were thin (4–5 mil) and thick (14 mil) latex. We found that medium to thick (6–8 mil) nitrile were not always perceived as comfortable and were expected to be more expensive than thin (4–5 mil) latex gloves. Of concern is the users’ difficulty to distinguish between nitrile and latex gloves; latex gloves are now sold in different colors including blue, which has traditionally been associated with nitrile gloves. Even though spray painters were familiar with the health hazards related to working with isocyanate paints; most were not always aware that dermal exposure to isocyanates could contribute to the development of occupational asthma. There is a need for more research to identify dermal materials that are protective against sprayed automotive coatings. Automotive spray painters and their employers need to be educated in the selection and use of protective gloves, specifically on attributes such as glove material, color, and thickness. PMID:24215135

  6. Influence of material properties on gloves' bacterial barrier efficacy in the presence of microperforation.

    Science.gov (United States)

    Bardorf, Michael Hermann; Jäger, Bernd; Boeckmans, Eric; Kramer, Axel; Assadian, Ojan

    2016-12-01

    Medical examination gloves and surgical gloves protect the wearer directly and the patient indirectly from the risk of contamination. Because of concerns related to latex allergy, an increasing trend toward the use of synthetic gloves made of materials other than latex is observable. However, currently it is unknown if the physical properties of different materials may influence bacterial passage in case of a glove puncture. We examined 9 different medical examination gloves from various manufacturers made of nitrile (n = 4), latex (n = 3), or neoprene (n = 2). Additionally, 1 latex surgical glove each with and without antibacterial chlorhexidine gluconate coating and 1 synthetic surgical glove made of thermoplastic elastomer were included in the experiments. The studied materials were perforated following a standardized procedure, and direct bacterial passage was measured under dynamic conditions. Glove elasticity at 1 cm up to 2.5 cm elongation was measured following EN 455-2. Nitrile gloves demonstrated higher material stiffness compared with latex gloves. Medical examination gloves made of nitrile and neoprene showed a 10-fold higher bacterial passage through a standardized puncture compared with latex gloves. All surgical gloves showed a lower bacterial passage compared with the tested examination gloves. Bacterial passage through punctures is correlated with the stiffness or elasticity of the glove material. Therefore, gloves made of latex may have an increased protective effect in case of a glove breach. Whenever gloves are purchased and selected, a risk-benefit assessment should be conducted, balancing the risk of allergy against the degree of required protection in case of a glove puncture. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  7. Is clinical performance adversely affected by wearing gloves during paediatric peripheral intravenous cannulation?

    Science.gov (United States)

    Zhang, Michael; Lee, Mark; Knott, Susan

    2014-10-01

    To investigate if wearing protective gloves during paediatric intravenous cannulation affects performance of the procedure. This was a prospective observational study. Peripheral intravenous cannulation (PIVC) performed within the Paediatric ED was observed and recorded over a 12 month period. Data were compared between those clinicians wearing gloves and those not wearing gloves during PIVC. One thousand and twenty paediatric cannulations were recorded during the observed period. The mean age of the children was 5.79 years. The overall success rate of cannulation was 86.18% and first attempt success rate 76.08%. Overall, gloves were used by 54.31% of clinicians to establish vascular access; glove use was lowest in the registrar group (41.11% compliance rate). The glove-wearing group had comparable overall success rate of 85.74% (475/554) to the no-gloves group of 86.70% (404/466). The difference was not statistically significant (P > 0.05). Higher incidence of significant blood spillage during the procedure was observed among clinicians wearing no gloves (16.74%) in comparison with their glove-wearing counterparts (9.03%, P glove-wearing group and no-gloves group (3.94% vs 3.76%, P > 0.05). The present study shows that the use of protective gloves was not associated with adverse outcomes of clinical performance during paediatric cannulation. The low compliance rate of gloves use is alarming, and many clinicians might be exposed to potential blood-borne infections. Clinicians should be encouraged and supported to use gloves for paediatric cannulation. © 2014 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  8. Fingers' vibration transmission and grip strength preservation performance of vibration reducing gloves.

    Science.gov (United States)

    Hamouda, K; Rakheja, S; Dewangan, K N; Marcotte, P

    2018-01-01

    The vibration isolation performances of vibration reducing (VR) gloves are invariably assessed in terms of power tools' handle vibration transmission to the palm of the hand using the method described in ISO 10819 (2013), while the nature of vibration transmitted to the fingers is ignored. Moreover, the VR gloves with relatively low stiffness viscoelastic materials affect the grip strength in an adverse manner. This study is aimed at performance assessments of 12 different VR gloves on the basis of handle vibration transmission to the palm and the fingers of the gloved hand, together with reduction in the grip strength. The gloves included 3 different air bladder, 3 gel, 3 hybrid, and 2 gel-foam gloves in addition to a leather glove. Two Velcro finger adapters, each instrumented with a three-axis accelerometer, were used to measure vibration responses of the index and middle fingers near the mid-phalanges. Vibration transmitted to the palm was measured using the standardized palm adapter. The vibration transmissibility responses of the VR gloves were measured in the laboratory using the instrumented cylindrical handle, also described in the standard, mounted on a vibration exciter. A total of 12 healthy male subjects participated in the study. The instrumented handle was also used to measure grip strength of the subjects with and without the VR gloves. The results of the study showed that the VR gloves, with only a few exceptions, attenuate handle vibration transmitted to the fingers only in the 10-200 Hz and amplify middle finger vibration at frequencies exceeding 200 Hz. Many of the gloves, however, provided considerable reduction in vibration transmitted to the palm, especially at higher frequencies. These suggest that the characteristics of vibration transmitted to fingers differ considerably from those at the palm. Four of the test gloves satisfied the screening criteria of the ISO 10819 (2013) based on the palm vibration alone, even though these caused

  9. Production of surgical gloves from low extractable protein RVNRL

    Energy Technology Data Exchange (ETDEWEB)

    Marga, Utama; Yanti, S.; Made, Sumarti; Marsongko; Tita, Puspitasari; Dian, Iramani [Center for Research and Development of Isotopes and Radiation Technology, National Nuclear Energy Agency, Jakarta (Indonesia); Makuuchi, K. [EB System Cooperation, Takasaki, Gunma (Japan); Yoshii, F. [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment; Siswanto [Research Unit for Biotechnology of Estate Crop (Indonesia)

    2001-03-01

    Study on the production of surgical gloves from low extractable protein PVNRL (Radiation Vulcanization of Natural Rubber Latex) in home industry scale with normal butyl acrylate as sensitizer has been carried out. The variation of dipping speed, concentration of coagulant agent and selection of antioxidant for producing good quality of surgical gloves were evaluated. The water-extractable protein and PBS (Phosphate Buffer Saline) - extractable protein content, the physical and mechanical properties of gloves were measured. The results show that for producing a good quality of surgical gloves from low extractable protein RVNRL, the concentration of latex is 50% with calcium nitrate as coagulant agent between 15-20%. By using this condition the physical and mechanical properties of surgical gloves is required to ASTM standard such as tensile strength more than 24 MPa, PBS-extractable protein is around 41-68 ug/g and water-extractable protein contents is around 23-35 ug/g. (author)

  10. Finger doses during interventional radiology: The value of flexible protective gloves

    International Nuclear Information System (INIS)

    Vehmas, T.

    1991-01-01

    Finger doses of radiologists and assistants during 19 interventional radiological procedures were measured with thermoluminescent dosimeters (TLDs), and two types of flexible protective gloves were compared with each other. There were considerable differences in doses between different sites of TLDs on fingers. The exact site of TLDs on hands/fingers should thus be reported in papers. Both gloves were also irradiated through an Alderson phantom and the attenuation values were measured. The gloves with slightly greater attenuation proved to be significantly less comfortable to use. Wearing flexible protective gloves did not lengthen screening times as compared to a previous study in the same department. Various aspects of using such gloves are discussed. The attenuation values of gloves reported by the manufacturers may not apply under all clinical circumstances. (orig.) [de

  11. Instrumented Glove Measures Positions Of Fingers

    Science.gov (United States)

    Bozeman, Richard J., Jr.

    1993-01-01

    Glove instrumented with flat membrane potentiometers to obtain crude measurements of relative positions of fingers. Resistance of each potentiometer varies with position of associated finger; translator circuit connected to each potentiometer converts analog reading to 1 of 10 digital levels. Digitized outputs from all fingers fed to indicating, recording, and/or data-processing equipment. Gloves and circuits intended for use in biomedical research, training in critical manual tasks, and other specialized applications.

  12. Glovebox glove deterioration in the Hanford Engineering Development Laboratory fuel fabrication facility

    International Nuclear Information System (INIS)

    Greenhalgh, W.O.; Smith, R.C.; Powell, D.L.

    1979-07-01

    Neoprene glovebox gloves have been found susceptible to periodic rapid deterioration under normal operating conditions in fuel fabrication facilities. Examinations of glove failure histories and measurements of the atmospheres in inert atmosphere dry-boxes indicated ozone at low concentrations of 100 to 500 ppB was probably the most important factor in rapid glove deterioration. Testing of a varity of new glove materials indicated that Hypalon and ethylene-propylene-diamine monomer (EDPM) gloves have greater than 30 times the longevity of neoprene in low-level ozone concentration atmospheres. comparative tests over a 30-month period have also confirmed that the two glove candidates have a significantly longer operative life. 14 figures

  13. Contamination of Unused, Nonsterile Gloves in the Critical Care Setting: A Comparison of Bacterial Glove Contamination in Medical, Surgical and Burn Intensive Care Units

    Directory of Open Access Journals (Sweden)

    Matthew Hall

    2014-01-01

    Conclusions: Despite differences in infection control practices and the composition of pathologies managed in each ICU, the average bioburden of gloves left exposed in the environment was not significantly different. Further research is needed to assess for an association of glove bioburden with nosocomial infection rates and the effects of different infection control practices on the reduction of glove bioburdens.

  14. Dexterity tests data contribute to reduction in leaded glovebox gloves use

    Energy Technology Data Exchange (ETDEWEB)

    Cournoyer, Michael E [Los Alamos National Laboratory; Lawton, Cindy M [Los Alamos National Laboratory; Castro, Amanda M [Los Alamos National Laboratory

    2008-01-01

    Programmatic operations at the Los Alamos National Laboratory Plutonium Facility (TA-55) involve working with various amounts of plutonium and other highly toxic, alphaemitting materials. The spread of radiological contamination on surfaces and airborne contamination and excursions of contaminants into the operator's breathing zone are prevented through the use of a variety of gloveboxes. Through an integrated approach, controls have been developed and implemented through an efficient Glovebox Glove Integrity Program (GGJP). A key element of this program is to consider measures that lower the overall risk of glovebox operations. Line management owning glovebox processes through this program make decisions on which type of glovebox gloves (the weakest component of this safety significant system) would perform in these aggressive environments. As Low As Reasonably Achievable (ALARA) considerations must be balanced with glove durability and worker dexterity, both of which affect the final overall risk of the operation. In the past, lead-loaded (leaded) glovebox gloves made from Hypalon(reg.) had been the workhorse of programmatic operations at TA-55. Replacing leaded gloves with unleaded gloves for certain operations would lower the overall risk as well as reduced the amount of mixed TRU waste. This effort contributes to Los Alamos National Laboratory Continuous Improvement Program by improving the efficiency, cost effectiveness, and formality of glovebox operations. In the following report, the pros and cons of wearing leaded glovebox gloves, the effect of leaded gloves versus unleaded gloves on task performance using standard dexterity tests, the justification for switching from leaded to unleaded gloves, and pollution prevention benefits of this dramatic change in the glovebox system are presented.

  15. Development and Test of Robotically Assisted Extravehicular Activity Gloves

    Science.gov (United States)

    Rogers, Jonathan M.; Peters, Benjamin J.; Laske, Evan A.; McBryan, Emily R.

    2017-01-01

    Over the past two years, the High Performance EVA Glove (HPEG) project under NASA's Space Technology Mission Directorate (STMD) funded an effort to develop an electromechanically-assisted space suit glove. The project was a collaboration between the Johnson Space Center's Software, Robotics, and Simulation Division and the Crew and Thermal Systems division. The project sought to combine finger actuator technology developed for Robonaut 2 with the softgoods from the ILC Phase VI EVA glove. The Space Suit RoboGlove (SSRG) uses a system of three linear actuators to pull synthetic tendons attached to the glove's fingers to augment flexion of the user's fingers. To detect the user's inputs, the system utilizes a combination of string potentiometers along the back of the fingers and force sensitive resistors integrated into the fingertips of the glove cover layer. This paper discusses the development process from initial concepts through two major phases of prototypes, and the results of initial human testing. Initial work on the project focused on creating a functioning proof of concept, designing the softgoods integration, and demonstrating augmented grip strength with the actuators. The second year of the project focused on upgrading the actuators, sensors, and software with the overall goal of creating a system that moves with the user's fingers in order to reduce fatigue associated with the operation of a pressurized glove system. This paper also discusses considerations for a flight system based on this prototype development and address where further work is required to mature the technology.

  16. The effects of arthritis gloves on people with Rheumatoid Arthritis or Inflammatory Arthritis with hand pain: a study protocol for a multi-centre randomised controlled trial (the A-GLOVES trial).

    Science.gov (United States)

    Prior, Yeliz; Sutton, Chris; Cotterill, Sarah; Adams, Jo; Camacho, Elizabeth; Arafin, Nazina; Firth, Jill; O'Neill, Terence; Hough, Yvonne; Jones, Wendy; Hammond, Alison

    2017-05-30

    Arthritis gloves are regularly provided as part of the management of people with rheumatoid arthritis (RA) and undifferentiated (early) inflammatory arthritis (IA). Usually made of nylon and elastane (i.e. Lycra®), these arthritis gloves apply pressure with the aims of relieving hand pain, stiffness and improving hand function. However, a systematic review identified little evidence supporting their use. We therefore designed a trial to compare the effectiveness of the commonest type of arthritis glove provided in the United Kingdom (Isotoner gloves) (intervention) with placebo (control) gloves (i.e. larger arthritis gloves providing similar warmth to the intervention gloves but minimal pressure only) in people with these conditions. Participants aged 18 years and over with RA or IA and persistent hand pain will be recruited from National Health Service Trusts in the United Kingdom. Following consent, participants will complete a questionnaire booklet, then be randomly allocated to receive intervention or placebo arthritis gloves. Within three weeks, they will be fitted with the allocated gloves by clinical specialist rheumatology occupational therapists. Twelve weeks (i.e. the primary endpoint) after completing the baseline questionnaire, participants will complete a second questionnaire, including the same measures plus additional questions to explore adherence, benefits and problems with glove-wear. A sub-sample of participants from each group will be interviewed at the end of their participation to explore their views of the gloves received. The clinical effectiveness and cost-effectiveness of the intervention, compared to placebo gloves, will be evaluated over 12 weeks. The primary outcome measure is hand pain during activity. Qualitative interviews will be thematically analysed. This study will evaluate the commonest type of arthritis glove (Isotoner) provided in the NHS (i.e. the intervention) compared to a placebo glove. The results will help

  17. Confirmation test on confinement performance of improved glove box

    International Nuclear Information System (INIS)

    Miura, S.; Kanazawa, J.; Nakajima, M.; Sakuno, K.; Miyata, H.

    1995-01-01

    Glove boxes are used at nuclear facilities to confine radioactive materials by ensuring a high level of airtightness and negative internal pressure. The allowable rate of air leakage is 0.1% vol/hr or less at the pre-service inspection. The negative pressure value is normally maintained at about -30 mm H 2 O. Structural strength and confinement reliability of glove boxes during earthquake are major concerns, and most important glove boxes are designed to withstand seismic class A events is Japan. This paper describes vibration tests done to confirm that improve large-sized glove boxes maintain their confinement performance and structural strength even during earthquake and that the design analysis methods used are appropriate. (author). 1 ref., 6 figs., 3 tabs

  18. Effect of shelf aging on vibration transmissibility of anti-vibration gloves

    Science.gov (United States)

    SHIBATA, Nobuyuki

    2017-01-01

    Anti-vibration gloves have been used in real workplaces to reduce vibration transmitted through hand-held power tools to the hand. Generally materials used for vibration attenuation in gloves are resilient materials composed of certain synthetic and/or composite polymers. The mechanical characteristics of the resilient materials used in anti-vibration gloves are prone to be influenced by environmental conditions such as temperature, humidity, and photo-irradiation, which cause material degradation and aging. This study focused on the influence of shelf aging on the vibration attenuation performance of air-packaged anti-vibration gloves following 2 yr of shelf aging. Effects of shelf aging on the vibration attenuation performance of anti-vibration gloves were examined according to the Japan industrial standard JIS T8114 test protocol. The findings indicate that shelf aging induces the reduction of vibration attenuation performance in air-packaged anti-vibration gloves. PMID:28978817

  19. Permeation of cytotoxic formulations through swatches from selected medical gloves.

    Science.gov (United States)

    Klein, Michael; Lambov, Nikolai; Samev, Nikola; Carstens, Gerhard

    2003-05-15

    The permeability of selected medical glove materials to various cytotoxic agents is described. Fifteen cytotoxic agents were prepared at the highest concentrations normally encountered by hospital personnel. Four single-layer and two double-layer glove systems made of two materials--latex and neoprene--were exposed to the drugs for 30, 60, 90, 120, 150, and 180 minutes. Circular sections of the glove material were cut from the cuff and evaluated without any pretreatment. Permeability tests were conducted in an apparatus consisting of a donor chamber containing the cytotoxic solution and a collection chamber filled with water (the acceptor medium). The two sections were separated by the glove material. Permeating portions, collected in water as the acceptor medium, were analyzed by either ultraviolet-visible light spectrophotometry or high-performance liquid chromatography (HPLC). Permeation rates were calculated on the basis of the concentration of the cytotoxic agent in the acceptor medium. Spectrophotometric measurements were taken every 30 minutes, and HPLC analysis was performed at the end of the three-hour period. Average permeation rates for 14 drugs were low (materials. All glove materials tested were impermeable to most of the cytotoxic agents over a period of three hours. Carmustine was the only agent that substantially permeated single-layer latex glove materials. Permeation of most tested cytotoxic formulations was low through swatches of material from various medical gloves.

  20. Latex Rubber Gloves as a Sampling Dosimeter Using a Novel Surrogate Sampling Device.

    Science.gov (United States)

    Sankaran, Gayatri; Lopez, Terry; Ries, Steve; Ross, John; Vega, Helen; Eastmond, David A; Krieger, Robert I

    2015-01-01

    Pesticide exposure during harvesting of crops occurs primarily to the workers' hands. When harvesters wear latex rubber gloves for personal safety and hygiene harvesting reasons, gloves accumulate pesticide residues. Hence, characterization of the gloves' properties may be useful for pesticide exposure assessments. Controlled field studies were conducted using latex rubber gloves to define the factors that influence the transfer of pesticides to the glove and that would affect their use as a residue monitoring device. A novel sampling device called the Brinkman Contact Transfer Unit (BCTU) was constructed to study the glove characteristics and residue transfer and accumulation under controlled conditions on turf. The effectiveness of latex rubber gloves as sampling dosimeters was evaluated by measuring the transferable pesticide residues as a function of time. The validation of latex rubber gloves as a residue sampling dosimeter was performed by comparing pesticide transfer and dissipation from the gloves, with the turf transferable residues sampled using the validated California (CA) Roller, a standard measure of residue transfer. The observed correlation (Pearson's correlation coefficient R(2)) between the two methods was .84 for malathion and .96 for fenpropathrin, indicating that the BCTU is a useful, reliable surrogate tool for studying available residue transfer to latex rubber gloves under experimental conditions. Perhaps more importantly, these data demonstrate that latex gloves worn by workers may be useful quantifiable matrices for measuring pesticide exposure.

  1. Content of Asthmagen Natural Rubber Latex Allergens in Commercial Disposable Gloves.

    Science.gov (United States)

    Bittner, C; Garrido, M V; Krach, L H; Harth, V

    The use of natural rubber latex (NRL) gloves in many occupations may lead to latex sensitization, allergic asthma, and skin reactions. Due to their good properties and environmental safety NRL gloves are still being used in the healthcare setting, but also in the food industry, by hairdressers, cleaners, etc. The aim of our study was to assess the protein and NRL allergen content in commercial gloves by different methods, including a new assay. Twenty commercially available NRL gloves were analyzed. Protein extraction was performed according to the international standard ASTM D-5712. Total protein content was measured with a modified Lowry method, NRL content with the CAP Inhibition Assay, the Beezhold ELISA Inhibition Assay, and an innovative ELISA with IgY-antibodies extracted from eggs of NRL-immunized hens (IgY Inhibition Assay). We found a high protein content in a range of 215.0-1304.7 μg/g in 8 out of the 20 NRL gloves. Seven of the 20 gloves were powdered, four of them with a high protein content. In gloves with high protein content, the immunological tests detected congruently high levels of NRL allergen. We conclude that a high percentage of commercially available NRL gloves still represent a risk for NRL allergy, including asthma. The modified Lowry Method allows to infer on the latex allergen content.

  2. Permeation of hair dye ingredients, p-phenylenediamine and aminophenol isomers, through protective gloves.

    Science.gov (United States)

    Lee, Hsiao-Shu; Lin, Yu-Wen

    2009-04-01

    Skin irritation and contact allergies are skin disorders common to hairdressers. The predominant oxidative hair dye components, such as p-phenylenediamine (PPD) and aminophenol isomers, can cause contact dermatitis. Use of protective gloves can prevent dermal contact with skin irritants. This study investigates the permeation behaviors of p-aminophenol (PAP), m-aminophenol (MAP), o-aminophenol (OAP) and PPD in single and mixed challenge solutions with disposable natural rubber latex (NRL) gloves, disposable polyvinylchloride (PVC) gloves and neoprene (NP) gloves. The challenge solutions were 4% PPD (w/v), 3% OAP (w/v), 2% PAP (w/v) and 2% MAP (w/v) in ethanol or 12% hydrogen peroxide solutions. The cocktail solutions of the four chemicals were also tested. An American Society for Testing and Materials type permeation cell, ethanol liquid collection and gas chromatography-flame ionization detection of samples taken from the collection medium every 10 min facilitated determination of breakthrough times (BTs), cumulative permeated masses and steady-state permeation rates (SSPRs). Experiments were 4 h long for the NRL and PVC gloves and 8 h for NP gloves. No chemicals tested broke through the NP gloves when exposed for 8 h. In the ethanol solution, PPD and OAP started breaking through the PVC gloves at 40 min. The SSPRs of PVC gloves were higher than those for NRL gloves in all challenge conditions for both single chemicals and mixtures. No tested chemicals in hydrogen peroxide solutions permeated the gloves during the 4-h tests. The chemical composition of the challenge solution was a main effecter of BTs and SSPRs for the NRL glove. For disposable PVC gloves, the main factors of BTs were molecular size [molar volume (MV)] and polarity (logK(ow)), and the primary factors of SSPRs were concentration, MV and logK(ow). In conclusion, disposable NRL gloves and disposable PVC gloves should not be used repeatedly for handling the hair dye products. Hydrogen peroxide did not

  3. Minimizing surgical skin incision scars with a latex surgical glove.

    Science.gov (United States)

    Han, So-Eun; Ryoo, Suk-Tae; Lim, So Young; Pyon, Jai-Kyung; Bang, Sa-Ik; Oh, Kap-Sung; Mun, Goo-Hyun

    2013-04-01

    The current trend in minimally invasive surgery is to make a small surgical incision. However, the excessive tensile stress applied by the retractors to the skin surrounding the incision often results in a long wound healing time and extensive scarring. To minimize these types of wound problems, the authors evaluated a simple and cost-effective method to minimize surgical incision scars based on the use of a latex surgical glove. The tunnel-shaped part of a powder-free latex surgical glove was applied to the incision and the dissection plane. It was fixed to the full layer of the dissection plane with sutures. The glove on the skin surface then was sealed with Ioban (3 M Health Care, St. Paul, MN, USA) to prevent movement. The operation proceeded as usual, with the retractor running through the tunnel of the latex glove. It was possible to complete the operation without any disturbance of the visual field by the surgical glove, and the glove was neither torn nor separated by the retractors. The retractors caused traction and friction during the operation, but the extent of damage to the postoperative skin incision margin was remarkably less than when the operation was performed without a glove. This simple and cost-effective method is based on the use of a latex surgical glove to protect the surgical skin incision site and improve the appearance of the postoperative scar. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  4. Permeation of Telone EC through protective gloves.

    Science.gov (United States)

    Zainal, Hanaa; Que Hee, Shane S

    2005-09-30

    Telone is a potent fumigant that is based on the chlorinated unsaturated hydrocarbon, 1,3-dichloropropene (1,3-DCP). It is often applied without dilution and so poses severe inhalation and air pollution threats. Urinary metabolites of 1,3-DCP have been detected after Telone skin exposure, so that preventing dermal exposure is also important. The objective of the study was to assess if nitrile and multi-layer ("laminated") gloves provide adequate protection against Telone EC formulation. To accomplish this, disposable (Safeskin) and chemically resistant (Sol-Vex) nitrile and laminated (Barrier mark and Silver Shield) glove materials were challenged by Telone EC with hexane liquid collection in an ASTM-type I-PTC-600 permeation cell. Analyses of cis- and trans-1,3-DCP in the collection fluid at specified times were performed on a moderately polar capillary column by gas chromatography-electron capture detection. Telone EC caused microholes in both nitrile materials, though the chemically protective material was degraded slower than the disposable nitrile. The laminated gloves offered limited protection. Silver Shield protected best because 1.5-2.3 mg 1,3-DCP permeated by 8 h relative to 2.5-7.6 mg for Barrier, implying about 2.5 times more protection for 8 h. Even for Silver Shield, the extent of protection was inadequate as illustrated by a risk assessment of the skin exposure situation. The normalized breakthrough times for both types of laminated gloves varied between 27 and 60 min. It is recommended that Viton gloves still be worn for protection.

  5. Permeation of aromatic solvent mixtures through nitrile protective gloves.

    Science.gov (United States)

    Chao, Keh-Ping; Hsu, Ya-Ping; Chen, Su-Yi

    2008-05-30

    The permeation of binary and ternary mixtures of benzene, toluene, ethyl benzene and p-xylene through nitrile gloves were investigated using the ASTM F739 test cell. The more slowly permeating component of a mixture was accelerated to have a shorter breakthrough time than its pure form. The larger differences in solubility parameter between a solvent mixture and glove resulted in a lower permeation rate. Solubility parameter theory provides a potential approach to interpret the changes of permeation properties for BTEX mixtures through nitrile gloves. Using a one-dimensional diffusion model based on Fick's law, the permeation concentrations of ASTM F739 experiments were appropriately simulated by the estimated diffusion coefficient and solubility. This study will be a fundamental work for the risk assessment of the potential dermal exposure of workers wearing protective gloves.

  6. Commercial golf glove effects on golf performance and forearm muscle activity.

    Science.gov (United States)

    Sorbie, Graeme G; Darroch, Paul; Grace, Fergal M; Gu, Yaodong; Baker, Julien S; Ugbolue, Ukadike C

    2017-01-01

    The study aimed to determine whether or not commercial golf gloves influence performance variables and forearm muscle activity during golf play. Fifteen golfers participated in the laboratory based study, each performing 8 golf swings with a Driver and 7-iron whilst wearing a glove and 8 without wearing the glove. Club head speed, ball speed and absolute carry distance performance variables were calculated. Surface electromyography was recorded from the flexor digitorum superficialis and extensor carpi radialis brevis on both forearm muscles. Club head speed, ball speed and absolute carry distance was significantly higher when using the Driver with the glove in comparison to the Driver without the glove (p < 0.05). No significant differences were evident when using the 7-iron and no significant differences were displayed in muscle activity in either of the conditions. Findings from this study suggest that driving performance is improved when wearing a glove.

  7. A study of clinicians' views on medical gloves and their effect on manual performance.

    Science.gov (United States)

    Mylon, Peter; Lewis, Roger; Carré, Matt J; Martin, Nicolas; Brown, Steven

    2014-01-01

    The effect of gloves on practitioners' performance has not been a major factor in their design. To determine the critical elements of performance and design appropriate tests, data from clinicians were needed. Semistructured interviews were carried out with medical practitioners from various disciplines, in which they were asked about their glove use, their views on gloves, medical tasks requiring the highest manual performance or most affected by gloves, and what the main issues with glove use were. Many participants expressed a preference for latex over nitrile, with glove fit being the main reason given. Satisfaction with surgical gloves (generally latex) was high but less so with examination gloves, which were generally nitrile. Tactile sensation, comfort, and donning were also seen as major issues with glove use. A number of tasks were identified for possible development as tests. Performance in medical practice needs to be clearly defined, separating perceived and measured performance, and understanding the effect of glove material, fit, and thickness. Development of new glove performance tests based on the tasks identified is an important part of this. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  8. Evaluation of Glove Damage during Dental Procedures among Dental Specialists in Tabriz

    Directory of Open Access Journals (Sweden)

    Saeed Nezafati

    2007-08-01

    Full Text Available

    Background and aims. Dental practitioners are prone to occupational risk of infection. This can be prevented in part by wearing gloves. However, for this to be effective, gloves should be intact during the entire course of dental procedure. Leaky surgical latex gloves have been seen in 0.9% of cases before use. As much as 1.9% of latex gloves have been reported to be damaged during dental procedures. In this study, we decided to assess glove damage during dental procedures among dental specialists in Tabriz.

    Materials and methods. Thirty-six dental specialists were selected for this study. Each practitioner received 40 pairs of intact powdered latex gloves. Upon the completion of dental procedures, the gloves were retrieved and any tears were evaluated separately for right and left hands. Data was analyzed using chi-square test.

    Results. 159 punctures were detected in 144 gloves (5% out of 2880 unpaired gloves used by practitioners. They noticed the tear(s in 60 cases (2%, however, 99 cases (3% of tear(s were not noted during the procedure. The highest rate of glove damage was observed in the prosthodontists’ group (12.3%, which was statistically significant comparing to other groups (p=0.048. The lowest rate of the damage was observed in the oral surgeons’ group (2% which showed no significant difference (p=0.134. The highest rate of punctures in the gloves was observed in the first and second fingers of the non-dominant hand.

    Conclusion. The damage to 5% of the gloves is highly significant, with a potential role in occupational hazards. The higher rate of leaks in the prosthodontists’ group compared to other groups demands for greater prudence in this field. The high rate of leaks in the first and second fingers of the non-dominant hand requires more attention to this area during daily practice.

  9. Changes in chemical permeation of disposable latex, nitrile, and vinyl gloves exposed to simulated movement.

    Science.gov (United States)

    Phalen, Robert N; Le, Thi; Wong, Weng Kee

    2014-01-01

    Glove movement can affect chemical permeation of organic compounds through polymer glove products. However, conflicting reports make it difficult to compare the effects of movement on chemical permeation through commonly available glove types. The aim of this study was to evaluate the effect of movement on chemical permeation of an organic solvent through disposable latex, nitrile, and vinyl gloves. Simulated whole-glove permeation testing was conducted using ethyl alcohol and a previously designed permeation test system. With exposure to movement, a significant decrease (p ≤ 0.001) in breakthrough time (BT) was observed for the latex (-23%) and nitrile gloves (-31%). With exposure to movement, only the nitrile glove exhibited a significant increase (p ≤ 0.001) in steady-state permeation rate (+47%) and cumulative permeation at 30 min (+111%). Even though the nitrile glove provided optimum chemical resistance against ethyl alcohol, it was most affected by movement. With exposure to movement, the latex glove was an equivalent option for overall worker protection, because it was less affected by movement and the permeation rate was lower than that of the nitrile glove. In contrast, the vinyl glove was the least affected by movement, but did not provide adequate chemical resistance to ethyl alcohol in comparison with the nitrile and latex gloves. Glove selection should take movement and polymer type into account. Some glove polymer types are less affected by movement, most notably the latex glove in this test. With nitrile gloves, at least a factor of three should be used when attempting to assign a protection factor when repetitive hand motions are anticipated. Ultimately, the latex gloves outperformed nitrile and vinyl in these tests, which evaluated the effect of movement on chemical permeation. Future research should aim to resolve some of the observed discrepancies in test results with latex and vinyl gloves.

  10. Investigation of X-ray permeability of surgical gloves coated with different contrast agents

    Science.gov (United States)

    Kayan, Mustafa; Yaşar, Selçuk; Saygın, Mustafa; Yılmaz, Ömer; Aktaş, Aykut Recep; Kayan, Fatmanur; Türker, Yasin; Çetinkaya, Gürsel

    2016-01-01

    Objective: We aimed to investigate the effectiveness and radiation protection capability of latex gloves coated with various contrast agents as an alternative to lead gloves. Methods: The following six groups were created to evaluate the permeability of X-ray in this experimental study: lead gloves, two different non-ionic contrast media (iopromide 370/100 mg I/mL and iomeprol 400/100 mg I/mL), 10% povidone–iodine (PV–I), 240/240 g/mL barium sulphate and a mixture of equal amounts of all contrast agents. A radiation dose detector was placed in coated latex gloves for each one. The absorption values of radiation from latex gloves coated with various contrast agents were measured and compared with the absorption of radiation from lead gloves. This study was designed as an ‘experimental study’. Results: The mean absorption value of X-ray from lead gloves was 3.0±0.08 µG/s. The mean absorption values of X-ray from latex gloves coated with various contrast agents were 3.7±0.09 µG/s (iopromide 370/100 mg I/mL), 3.6±0.09 µG/s (iomeprol 400/100 mg I/mL), 3.7±0.04 µG/s (PV–I), 3.1±0.07 µG/s (barium sulphate) and 3.8±0.05 µG/s (mixture of all contrast agents). Latex gloves coated with barium sulphate provided the best radiation absorption compared with latex gloves coated with other radiodense contrast agents. Conclusion: Latex gloves coated with barium sulphate may provide protection equivalent to lead gloves. PMID:26680548

  11. Whole glove permeation of cyclohexanol through disposable nitrile gloves on a dextrous robot hand and comparison with the modified closed-loop ASTM F739 method 1. No fist clenching.

    Science.gov (United States)

    Mathews, Airek R; Que Hee, Shane S

    2017-04-01

    The aim was to develop a whole glove permeation method for cyclohexanol to generate permeation parameter data for a non-moving dextrous robot hand (normalized breakthrough time t b , standardized breakthrough time t s , steady state permeation rate P s , and diffusion coefficient D). Four types of disposable powderless, unsupported, and unlined nitrile gloves from the same producer were investigated: Safeskin Blue and Kimtech Science Blue, Purple, and Sterling. The whole glove method developed involved a peristaltic pump for water circulation through chemically resistant Viton tubing to continually wash the inner surface of the test glove via holes in the tubing, a dextrous robot hand operated by a microprocessor, a chemically protective nitrile glove to protect the robot hand, an incubator to maintain 35°C temperature, and a hot plate to maintain 35°C at the sampling point of the circulating water. Aliquots of 1.0 mL were sampled at regular time intervals for the first 60 min followed by removal of 0.5 mL aliquots every hour to 8 hr. Quantification was by the internal standard method after gas chromatography-selective ion electron impact mass spectrometry using a non-polar capillary column. The individual glove values of t b and t s differed for the ASTM closed loop method except for Safeskin Blue, but did not for the whole glove method. Most of the kinetic parameters agreed within an order of magnitude for the two techniques. The order of most protective to least protective glove was Blue and Safeskin, then Purple followed by Sterling for the whole gloves. The analogous order for the modified F739 ASTM closed loop method was: Safeskin, Blue, Purple, and Sterling, almost the same as for the whole glove. The Sterling glove was "not recommended" from the modified ASTM data, and was "poor" from the whole glove data.

  12. A System for Cooling inside a Glove Box

    Science.gov (United States)

    Sanz, Martial

    2010-01-01

    An easy, efficient, reliable, and low-cost method of constructing a cooling system using a simple circulating pump is described. The system is employed in conjunction with an inert atmosphere glove box to achieve the synthesis of air- and moisture-sensitive compounds inside the glove box at controlled, low temperatures without contaminating the…

  13. Decrease the Number of Glovebox Glove Breaches and Failures

    Energy Technology Data Exchange (ETDEWEB)

    Hurtle, Jackie C. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2013-12-24

    Los Alamos National Laboratory (LANL) is committed to the protection of the workers, public, and environment while performing work and uses gloveboxes as engineered controls to protect workers from exposure to hazardous materials while performing plutonium operations. Glovebox gloves are a weak link in the engineered controls and are a major cause of radiation contamination events which can result in potential worker exposure and localized contamination making operational areas off-limits and putting programmatic work on hold. Each day of lost opportunity at Technical Area (TA) 55, Plutonium Facility (PF) 4 is estimated at $1.36 million. Between July 2011 and June 2013, TA-55-PF-4 had 65 glovebox glove breaches and failures with an average of 2.7 per month. The glovebox work follows the five step safety process promoted at LANL with a decision diamond interjected for whether or not a glove breach or failure event occurred in the course of performing glovebox work. In the event that no glove breach or failure is detected, there is an additional decision for whether or not contamination is detected. In the event that contamination is detected, the possibility for a glove breach or failure event is revisited.

  14. Analysis of Asymmetric Aircraft Aerodynamics Due to an Experimental Wing Glove

    Science.gov (United States)

    Hartshorn, Fletcher

    2011-01-01

    Aerodynamic analysis on a business jet with a wing glove attached to one wing is presented and discussed. If a wing glove is placed over a portion of one wing, there will be asymmetries in the aircraft as well as overall changes in the forces and moments acting on the aircraft. These changes, referred to as deltas, need to be determined and quantified to make sure the wing glove does not have a drastic effect on the aircraft flight characteristics. TRANAIR, a non-linear full potential solver was used to analyze a full aircraft, with and without a glove, at a variety of flight conditions and angles of attack and sideslip. Changes in the aircraft lift, drag and side force, along with roll, pitch and yawing moment are presented. Span lift and moment distributions are also presented for a more detailed look at the effects of the glove on the aircraft. Aerodynamic flow phenomena due to the addition of the glove and its fairing are discussed. Results show that the glove used here does not present a drastic change in forces and moments on the aircraft, but an added torsional moment around the quarter-chord of the wing may be a cause for some structural concerns.

  15. The influence of hydrogen peroxide on the permeability of protective gloves to resorcinol in hairdressing.

    Science.gov (United States)

    Lind, Marie-Louise; Johnsson, Stina; Lidén, Carola; Meding, Birgitta; Boman, Anders

    2015-01-01

    Hairdressers are exposed to hair dye chemicals, for example resorcinol and hydrogen peroxide. Adequate skin protection is an important preventive measure against occupational skin disease. To examine whether hydrogen peroxide may cause deterioration of protective gloves. Permeation of resorcinol through gloves of polyvinylchloride (PVC) (n = 8), natural rubber latex (NRL) (n = 5) and nitrile rubber (NR) (n = 5) was studied in a two-compartment cell, with resorcinol as an indicator for hair dyes. The amount of resorcinol that had permeated was analysed with a high-performance liquid chromatography instrument. Cumulative breakthrough time and permeation rate were compared for hydrogen peroxide-pretreated and untreated gloves. The cumulative breakthrough time was > 1 hr but gloves. Pretreatment of PVC gloves resulted in a slightly decreased breakthrough time, and pretreatment of NRL gloves decreased the permeation rate. No change was recorded in NR gloves. Treatment with hydrogen peroxide had a minor effect on permeation in the tested gloves. NR gloves provided the best protection. However, taking the allergy risk of rubber gloves into account, plastic gloves are recommended in hairdressing. PVC gloves may be used, but not for > 1 hr. Disposable gloves should never be reused, regardless of material. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. The Potential of Wearable Sensor Technology for EVA Glove Ergonomic Evaluation

    Science.gov (United States)

    Reid, Christopher R.; McFarland, Shane; Norcross, Jason R.; Rajulu, Sudhakar

    2014-01-01

    Injuries to the hands are common among astronauts who train for extravehicular activity (EVA). Many of these injuries refer to the gloves worn during EVA as the root cause. While pressurized, the bladder and outer material of these gloves restrict movement and create pressure points while performing tasks, sometimes resulting in pain, muscle fatigue, abrasions, and occasionally a more severe injury, onycholysis (fingernail delamination). The most common injury causes are glove contact (pressure point/rubbing), ill-fitting gloves, and/or performing EVA tasks in pressurized gloves. A brief review of the Lifetime Surveillance of Astronaut Health's injury database reveals over 57% of the total injuries to the upper extremities during EVA training occurred either to the metacarpophalangeal (MCP) joint, fingernail, or the fingertip. Twenty-five of these injuries resulted in a diagnosis of onycholysis

  17. Evaluation of decontamination during dismantling of plutonium-contaminated glove boxes

    International Nuclear Information System (INIS)

    Kinugasa, Manabu; Taguchi, Seigi; Ohzeki, Satoru; Inoue, Yoshiaki; Kashima, Sadamitsu

    1981-01-01

    The dismantling work of plutonium-contaminated glove boxes was carried out. These glove boxes had been used for the R and D of plutonium-uranium mixed oxide fuel for 15 years. The work was carried out in a pressure-controlled greenhouse, and the contamination of air in the greenhouse was monitored continuously. In order to reduce the contamination of air during dismantling, the decontamination and fixation of loose contaminants on the surfaces of glove boxes were very important. The correlation between decontamination and the contamination of air regarding dismantling is reported in this paper. The surface contamination density of the glove boxes was measured utilizing the smear method before and after the decontamination, and the decontamination effects were estimated. The contamination of air during dismantling was continuously measured with a plutonium dust monitor. It was found that loose contamination exponentially decreased by the decontamination process. When the so-called wet glove boxes, which contained wet recovery and waste disposal apparatus, were dismantled, the contamination of air did not exceed 500 (MPC) a. However, the contamination of air exceeded 500 (MPC) a several times in the present work of dismantling the so-called dry glove boxes which had been used for the fabrication of plutonium-uranium mixed oxide pellets. (Kato, T.)

  18. Protective gloves on manual sugar cane cutting are really effective?

    Science.gov (United States)

    Abrahão, R F; Gonzaga, M C; Braunbeck, O A

    2012-01-01

    Problems related to the use of personal protective equipment (PPE), specially the use of protective gloves for the manual sugar cane cutting, motivated this research, made possible by a tripartite negotiation involving the Ministry of Labor, the Union of Rural Workers and the Employer's Association of sugarcane agribusiness. The main objective was to evaluate, from an ergonomics perspective, the impact of use of the gloves during the manual cane sugar cutting, raising questions on safety, effectiveness and comfort. The research was carried in a sugarcane industry of São Paulo for two seasons involving 47 workers who made a qualitative analysis of acceptance of four models of protective gloves. The methodology included the use of semi-structured interviews, questionnaires and field observations and the experimental determination of the coefficient of static friction developed between the gloves and the surfaces of the machete handle. The main results indicate the general inadequacy of the gloves currently used forcing the employees to improvise. Workers found the glove of leather and nylon scraping the best reported for comfort in use. The overall results highlight the problem of detachment of test standards for the manufacture of PPE, ignoring users and the activity to be performed.

  19. Anatomy of a defective barrier: sequential glove leak detection in a surgical and dental environment.

    Science.gov (United States)

    Albin, M S; Bunegin, L; Duke, E S; Ritter, R R; Page, C P

    1992-02-01

    a) To determine the frequency of perforations in latex surgical gloves before, during, and after surgical and dental procedures; b) to evaluate the topographical distribution of perforations in latex surgical gloves after surgical and dental procedures; and c) to validate methods of testing for latex surgical glove patency. Multitrial tests under in vitro conditions and a prospective sequential patient study using consecutive testing. An outpatient dental clinic at a university dental school, the operating suite in a medical school affiliated with the Veteran's Hospital, and a biomechanics laboratory. Surgeons, scrub nurses, and dental technicians participating in 50 surgical and 50 dental procedures. We collected 679 latex surgical gloves after surgical procedures and tested them for patency by using a water pressure test. We also employed an electronic glove leak detector before donning, after sequential time intervals, and upon termination of 47 surgical (sequential surgical), 50 dental (sequential dental), and in three orthopedic cases where double gloving was used. The electronic glove leak detector was validated by using electronic point-by-point surface probing, fluorescein dye diffusion, as well as detecting glove punctures made with a 27-gauge needle. The random study indicated a leak rate of 33.0% (224 out of 679) in latex surgical gloves; the sequential surgical study demonstrated patency in 203 out of 347 gloves (58.5%); the sequential dental study showed 34 leaks in the 106 gloves used (32.1%); and with double gloving, the leak rate decreased to 25.0% (13 of 52 gloves tested). While the allowable FDA defect rate for unused latex surgical gloves is 1.5%, we noted defect rates in unused gloves of 5.5% in the sequential surgical, 1.9% in the sequential dental, and 4.0% in our electronic glove leak detector validating study. In the sequential surgical study, 52% of the leaks had occurred by 75 mins, and in the sequential dental study, 75% of the leaks

  20. [Do double gloves protect against contamination during cannulation of blood vessels? A prospective randomized study].

    Science.gov (United States)

    Szarpak, Łukasz; Kurowski, Andrzej

    2014-01-01

    Undamaged medical gloves protect medical personnel from contact with physiological fluids of the patient. Thus they protect the assistance provider from hand skin contamination with potentially infectious biological materials. The aim of the study was to evaluate the occurrence of pierce, perforations or damage of medical gloves during cannulation of blood vessels. In the prospective randomized study 303 pairs of gloves, used during cannulation of blood vessels under simulated resuscitation, were analyzed. Gloves were tested by the water leak test. The water test revealed 44 cases of damage to the gloves used during cannulation of blood vessels. Significant differences were noted in the frequency of damage to both the outer and single pairs of gloves and the inner pair of gloves. The study showed that the use of double gloves provides a higher level of security for a paramedic than the use of a single pair of gloves, however, double gloves reduce the manual dexterity of a paramedic. A large number of damages to gloves are not noticed by medical personnel during surgery.

  1. Space suit glove design with advanced metacarpal phalangeal joints and robotic hand evaluation.

    Science.gov (United States)

    Southern, Theodore; Roberts, Dustyn P; Moiseev, Nikolay; Ross, Amy; Kim, Joo H

    2013-06-01

    One area of space suits that is ripe for innovation is the glove. Existing models allow for some fine motor control, but the power grip--the act of grasping a bar--is cumbersome due to high torque requirements at the knuckle or metacarpal phalangeal joint (MCP). This area in particular is also a major source of complaints of pain and injury as reported by astronauts. This paper explores a novel fabrication and patterning technique that allows for more freedom of movement and less pain at this crucial joint in the manned space suit glove. The improvements are evaluated through unmanned testing, manned testing while depressurized in a vacuum glove box, and pressurized testing with a robotic hand. MCP joint flex score improved from 6 to 6.75 (out of 10) in the final glove relative to the baseline glove, and torque required for flexion decreased an average of 17% across all fingers. Qualitative assessments during unpressurized and depressurized manned testing also indicated the final glove was more comfortable than the baseline glove. The quantitative results from both human subject questionnaires and robotic torque evaluation suggest that the final iteration of the glove design enables flexion at the MCP joint with less torque and more comfort than the baseline glove.

  2. Comparison of the effect of using latex and nitrile gloves hand dexterity among Iranian population

    Directory of Open Access Journals (Sweden)

    T. Allahyari

    2014-02-01

    .Conclusion: Considering that there was no significant difference in the score of both fine finger and gross hand dexterity while using nitrile gloves as compared to the control condition (without gloves, means that use of nitrile gloves has no adverse effect on hand dexterity therefore, using nitrile gloves is recommended as a alternative for the latex gloves, considering the additional advantage of no allergic reaction in this gloves.

  3. Glove box posting system

    International Nuclear Information System (INIS)

    McIntosh, A.E.

    1981-01-01

    A system for posting objects into closed containers, such as glove boxes, is described in which the bag used, preferably made of plastic, does not have to be fitted and sealed by the operator during each posting operation. (U.K.)

  4. Tactile sensitivity of gloved hands in the cold operation.

    Science.gov (United States)

    Geng, Q; Kuklane, K; Holmér, I

    1997-11-01

    In this study, tactile sensitivity of gloved hand in the cold operation has been investigated. The relations among physical properties of protective gloves and hand tactile sensitivity and cold protection were also analysed both objectively and subjectively. Subjects with various gloves participated in the experimental study during cold exposure at different ambient temperatures of -12 degrees C and -25 degrees C. Tactual performance was measured using an identification task with various sizes of objects over the percentage of misjudgment. Forearm, hand and finger skin temperatures were also recorded throughout. The experimental data were analysed using analysis of variance (ANOVA) model and the Tukey's multiple range test. The results obtained indicated that the tactual performance was affected both by gloves and by hands/fingers cooling. Effect of object size on the tactile discrimination was significant and the misjudgment increased when similar sizes of objects were identified, especially at -25 degrees C.

  5. Glovebox glove change program at Technical Area 55, Los Alamos National Laboratory

    International Nuclear Information System (INIS)

    Olivas, J.D.; Burkett, B.O.; Weier, D.R.

    1992-01-01

    A formal glovebox glove change program is planned for the the gloveboxes in technical area 55 at the Los Alamos National laboratory. The program will increase worker safety by reducing the chance of having worn out gloves in service. The Los Alamos program is based on a similar successful program at the Rocky Flats Plant in Golden, Colorado. Glove change frequencies at Rocky Flats were determined statistically, and are based on environmental factors the glovebox gloves are subjected to

  6. Spacesuit Glove-Induced Hand Trauma and Analysis of Potentially Related Risk Variables

    Science.gov (United States)

    Charvat, Chacqueline M.; Norcross, Jason; Reid, Christopher R.; McFarland, Shane M.

    2015-01-01

    Injuries to the hands are common among astronauts who train for extravehicular activity (EVA). When the gloves are pressurized, they restrict movement and create pressure points during tasks, sometimes resulting in pain, muscle fatigue, abrasions, and occasionally more severe injuries such as onycholysis. Glove injuries, both anecdotal and recorded, have been reported during EVA training and flight persistently through NASA's history regardless of mission or glove model. Theories as to causation such as glove-hand fit are common but often lacking in supporting evidence. Previous statistical analysis has evaluated onycholysis in the context of crew anthropometry only. The purpose of this study was to analyze all injuries (as documented in the medical records) and available risk factor variables with the goal to determine engineering and operational controls that may reduce hand injuries due to the EVA glove in the future. A literature review and data mining study were conducted between 2012 and 2014. This study included 179 US NASA crew who trained or completed an EVA between 1981 and 2010 (crossing both Shuttle and ISS eras) and wore either the 4000 Series or Phase VI glove during Extravehicular Mobility Unit (EMU) spacesuit EVA training and flight. All injuries recorded in medical records were analyzed in their association to candidate risk factor variables. Those risk factor variables included demographic characteristics, hand anthropometry, glove fit characteristics, and training/EVA characteristics. Utilizing literature, medical records and anecdotal causation comments recorded in crewmember injury data, investigators were able to identify several risk factors associated with increased risk of glove related injuries. Prime among them were smaller hand anthropometry, duration of individual suited exposures, and improper glove-hand fit as calculated by the difference in the anthropometry middle finger length compared to the baseline EVA glove middle finger length.

  7. A Glove for Tapping and Discrete 1D/2D Input

    Science.gov (United States)

    Miller, Sam A.; Smith, Andy; Bahram, Sina; SaintAmant, Robert

    2012-01-01

    This paper describes a glove with which users enter input by tapping fingertips with the thumb or by rubbing the thumb over the palmar surfaces of the middle and index fingers. The glove has been informally tested as the controller for two semi-autonomous robots in a a 3D simulation environment. A preliminary evaluation of the glove s performance is presented.

  8. A Dexterity and Tactility Evaluation of the Australian Nuclear Biological Chemical (NBC) Glove

    National Research Council Canada - National Science Library

    Scanlan, S

    2004-01-01

    This report details the tactility and dexterity of four different glove types, including the Australian in-service NBC butyl rubber glove and Nomex flying glove for standardized (Purdue pegboard) and operational...

  9. Vibration-reducing gloves: transmissibility at the palm of the hand in three orthogonal directions.

    Science.gov (United States)

    McDowell, Thomas W; Dong, Ren G; Welcome, Daniel E; Xu, Xueyan S; Warren, Christopher

    2013-01-01

    Vibration-reducing (VR) gloves are commonly used as a means to help control exposures to hand-transmitted vibrations generated by powered hand tools. The objective of this study was to characterise the vibration transmissibility spectra and frequency-weighted vibration transmissibility of VR gloves at the palm of the hand in three orthogonal directions. Seven adult males participated in the evaluation of seven glove models using a three-dimensional hand-arm vibration test system. Three levels of hand coupling force were applied in the experiment. This study found that, in general, VR gloves are most effective at reducing vibrations transmitted to the palm along the forearm direction. Gloves that are found to be superior at reducing vibrations in the forearm direction may not be more effective in the other directions when compared with other VR gloves. This casts doubts on the validity of the standardised glove screening test. Practitioner Summary: This study used human subjects to measure three-dimensional vibration transmissibility of vibration-reducing gloves at the palm and identified their vibration attenuation characteristics. This study found the gloves to be most effective at reducing vibrations along the forearm direction. These gloves did not effectively attenuate vibration along the handle axial direction.

  10. Radiation Sterilization of Naturual Rubber Examination Gloves

    International Nuclear Information System (INIS)

    Jetawattana, S.; Na-Ranong, N.; Kajornchaiyakul, V.

    1998-01-01

    The sterilization dose setting by ISO 11137 method 1 was conducted for natural rubber examination gloves provided by a local factory. The suitable sterilization dose for an average product bioburden falls between 20 - 25 kilogray. Maximum dose of 25 or 50 kilogray results in no changes of tensile s and elongation at break. Samples of examination glove were irradiated using various doses between 10 - 50 kilogray. Analysis of soluble protein content using modified Lowry method was carried out and the results revealed that irradiation did not affect the decrement of soluble protein content in this case. However, thin film samples were prepared in laboratory and treated in the same procedure. The results were also the same. The results did not show any correlation. Two factors are possibly presumed : un consistency of samples and the irradiation of finished products could not affect those soluble proteins in rubber gloves

  11. The Influence of Glove Type on Simulated Wheelchair Racing Propulsion: A Pilot Study.

    Science.gov (United States)

    Rice, I; Dysterheft, J; Bleakney, A W; Cooper, R A

    2016-01-01

    Our purpose was to examine the influence of glove type on kinetic and spatiotemporal parameters at the handrim in elite wheelchair racers. Elite wheelchair racers (n=9) propelled on a dynamometer in their own racing chairs with a force and moment sensing wheel attached. Racers propelled at 3 steady state speeds (5.36, 6.26 & 7.60 m/s) and performed one maximal effort sprint with 2 different glove types (soft & solid). Peak resultant force, peak torque, impulse, contact angle, braking torque, push time, velocity, and stroke frequency were recorded for steady state and sprint conditions. Multiple nonparametric Wilcoxon matched pair's tests were used to detect differences between glove types, while effect sizes were calculated based on Cohen's d. During steady state trials, racers propelled faster, using more strokes and larger contact angle, while applying less impulse with solid gloves compared to soft gloves. During the sprint condition, racers achieved greater top end velocities, applying larger peak force, with less braking torque with solid gloves compared to soft gloves. Use of solid gloves may provide some performance benefits to wheelchair racers during steady state and top end velocity conditions. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Replacement of the glove box panel in nuclear fuel reprocessing facility

    International Nuclear Information System (INIS)

    Yamamoto, Masahiko; Shirouzu, Hidetomo; Mori, Eito; Surugaya, Naoki

    2016-05-01

    The panels for visual confirmation of glove box installed at Operation Testing Laboratory in Tokai Reprocessing Plant have been deteriorated and transparencies have been decreased due to the long-term use. Therefore, the glove box panels have been replaced from the view point of preventive maintenance. In the new regulation formulated since the accident at Tokyo Electric Power Company's Fukushima Daiichi Nuclear Power Station, it is demanded that the glove box consists of incombustible or noncombustible materials. In this replacement, the new panels have been manufactured with the polycarbonate which satisfied the UL94 V-0 incombustible class. The glove box has been in service for 40 years and its inside is contaminated with radioactive materials. Thus, the contaminations have been investigated and decontaminated before the replacement work. Then, operator's exposure and radiation protection equipment have been estimated. Also, it is necessary to replace the panels with maintaining the glove box's enclosure function. The replacement has been conducted in closed space covering the opening parts with vinyl sheets. The enclosure function has been verified by the inspection of the new panels and glove box. (author)

  13. Energy evaluation of protection effectiveness of anti-vibration gloves.

    Science.gov (United States)

    Hermann, Tomasz; Dobry, Marian Witalis

    2017-09-01

    This article describes an energy method of assessing protection effectiveness of anti-vibration gloves on the human dynamic structure. The study uses dynamic models of the human and the glove specified in Standard No. ISO 10068:2012. The physical models of human-tool systems were developed by combining human physical models with a power tool model. The combined human-tool models were then transformed into mathematical models from which energy models were finally derived. Comparative energy analysis was conducted in the domain of rms powers. The energy models of the human-tool systems were solved using numerical simulation implemented in the MATLAB/Simulink environment. The simulation procedure demonstrated the effectiveness of the anti-vibration glove as a method of protecting human operators of hand-held power tools against vibration. The desirable effect is achieved by lowering the flow of energy in the human-tool system when the anti-vibration glove is employed.

  14. An evaluation of hospital hand hygiene practice and glove use in Hong Kong.

    Science.gov (United States)

    Chau, Janita P-C; Thompson, David R; Twinn, Sheila; Lee, Diana T F; Pang, Sharon W M

    2011-05-01

    To identify omissions in hand hygiene practice and glove use among hospital workers in Hong Kong. Hospital-acquired infection is the commonest complication affecting hospitalised patients. Even though research evidence suggests that hand hygiene and proper glove use are the most important ways to prevent the spread of disease and infection, compliance with both are reported to be unacceptably low. An observational study of hospital workers in one acute and two convalescence and rehabilitation hospitals in Hong Kong was conducted. The participating clinical areas included the medical and surgical wards, accident and emergency department and intensive care unit. Hand hygiene practice and glove use amongst 206 hospital health and support workers, stratified according to years of working experience, were observed. The number of observed episodes for hand hygiene was 1037 and for glove use 304. Compliance with hand hygiene was 74.7% and with glove use 72.4%. In approximately two-third of episodes, participants washed their hands after each patient contact; though, 78.5% failed to rub their hands together vigorously for at least 15 seconds. The major break in compliance with glove use was failure to change gloves between procedures on the same patient. In 28.6% of observed glove use episodes, participants did not wear gloves during procedures that exposed them to blood, body fluids, excretion, non-intact skin or mucous membranes. Significant differences in performance scores on antiseptic hand rub were found between the two types of hospital and on glove use between the three groups of work experience: ≤ 5, 6-10, >10 years. Education and reinforcement of proper hand hygiene practice and glove use among hospital health and support workers is needed. © 2011 Blackwell Publishing Ltd.

  15. Bacterial contamination of surgeons' gloves during shunt insertion; a pilot study

    DEFF Research Database (Denmark)

    Sørensen, Preben; Ejlertsen, Tove; Aaen, Dorte

    2008-01-01

    antibiotics and double gloving, by surgeons experienced in shunt surgery. Surgical incision, dissection and tunnelling were done. Then the surgeon, the scrub-nurse and, in three cases, the assistant made an imprint of their outer gloves on agar plates. Hereafter, they changed the outer pair of gloves before...... handling the shunt and completing the operation. The plates were cultured for 6 days in both aerobic and anaerobic environment. In all cases the surgeons gloves were contaminated, and in six cases also the nurses' gloves were contaminated, as well as all three assistants. Propionebacterium acnes were...... nurse and assistant were contaminated with micro-organisms less than 15 min after surgery has been commenced and before the shunts were handled. This study offers a feasible, simple and logical explanation of how shunts may become contaminated and infected. A simple measure would be to change the outer...

  16. High Performance EVA Gloves (HPEG)

    Data.gov (United States)

    National Aeronautics and Space Administration — In collaboration with HEOMD's Human Research Program, we are researching mechanisms for hand injury and will be developing new gloves to significantly reduce injury...

  17. Design of a new non-sterile glove-dispensing unit to reduce touch-based contamination

    Directory of Open Access Journals (Sweden)

    Jennifer R Amos

    2014-06-01

    Full Text Available Background Despite best efforts by healthcare providers to sterilise their hands through hand washing prior to touching medical equipment and patients, bacteria are still present and can be spread through physical contact. We aimed to reduce the spread of touch-induced and airborne bacteria and virus spreading by using a touch-free glove-dispensing system that minimally exposes gloves in the box to air. Method The team met multiple times to undertake early prototyping and present ideas for the design. We experimented with folding gloves in varying patterns, similar to facial tissue-dispensing boxes, and tried several methods of opening/closing the glove box to determine the most effective way to access gloves with the least amount of physical contact. We considered the user experience and obtained user feedback after each design iteration. Results Ultimately, we decided on a vertically oriented box with optional holes for dispensing a glove on the side of the box or on the bottom by means of the pull-down drawer mechanism. This system will dispense a single glove at a time to the user with the option of using a pull-down drawer trigger to decrease the likelihood of physical contact with unused gloves. Both methods dispense a single glove. Conclusion: By reducing physical contact between the healthcare practitioner and the gloves, we are potentially reducing the spread of bacteria. This glove box design ensures that gloves are not exposed to the air in the clinic or hospital setting, thereby further reducing spread of airborne germs. This could assist in decreasing the risk of nosocomial infections in healthcare settings.

  18. Alpha contamination assessment for D ampersand D activities: Monitoring inside glove boxes and vessels

    International Nuclear Information System (INIS)

    Rawool-Sullivan, M.W.; Bolton, R.D.; Conaway, J.G.; MacArthur, D.W.

    1996-02-01

    We have developed a new approach to glove box monitoring that involves drawing air out of one glove port through a detection grid that collects ions created in the air inside the glove box by ionizing radiation, especially alpha radiation. The charge deposited on the detection grid by the ions is measured with a sensitive electrometer. The air can be circulated back to the glove box through the other glove port, preventing contamination from leaving the glove box and detector system. Initial experiments using a mock-up constructed of sheet metal indicate that this technology provides the measurement technique needed to perform a defensible, non-invasive measurement of alpha contamination inside glove boxes destined for waste disposal. This can result in an enormous cost savings if a given glove box can be shown to fall into the catagory of Low-Level Waste rather than Trans-Uranic Waste. Considering that hundreds of glove boxes contaminated with plutonium will be taken out of service at various nuclear facilities over the next few years, the potential cost savings associated with disposal as LLW rather than TRU waste are substantial

  19. How do gloves affect cutaneous sensibility in medical practice? Two new applied tests.

    Science.gov (United States)

    Mylon, Peter; Carré, Matt J; Martin, Nicolas; Lewis, Roger

    2017-01-01

    In order to quantify the effect of medical gloves on tactile performance, two new Simulated Medical Examination Tactile Tests (SMETT) have been developed to replicate the tactile and haptic ability required in medical examinations: the 'Bumps' test and the 'Princess and the Pea' (P&P) test. A pilot study was carried out using 30-40 subjects for each test in order to investigate the suitability of the tests for medical glove evaluation. Tests were performed with latex and nitrile examination gloves and without gloves. Following the tests, small-scale studies were carried out to investigate the effect of various design parameters, such as material stiffness and tactile exploration method. In the 'Bumps' test, subjects performed significantly better in the ungloved condition, and there were 'almost significant' differences between the gloves, with the thinner latex gloves performing better than the thicker nitrile gloves. Both finger orientation and surface lubrication were found to have a significant effect on results, indicating that these need to be clearly defined in the test procedure. In the 'P&P' test, no significant effect of hand condition was found, suggesting that haptic sensing is less affected by medical gloves than cutaneous sensibility. Other factors such as material stiffness, technique and test orientation had a more significant effect. The SMETT 'Bumps' test has potential as a clinical manual performance evaluation tool and may be used to evaluate the relative effects of different gloves. The SMETT 'P&P' test is a valid measure of haptic or tactile performance, but should not be used in glove evaluation. Both tests could have further applications, such as in the assessment of neurological impairment or aptitude testing for potential surgeons.

  20. The measurement of water vapor permeability of glove materials using dilute tritiated water

    International Nuclear Information System (INIS)

    Doughty, D.H.

    1982-01-01

    As fusion technology progresses, there will be an increasing need to handle tritium and tritiated compounds. Protective clothing, especially drybox gloves, must be an effective barrier to minimize worker exposure. The water vapor permeability of glove materials and finished glove constructions is a crucial property of drybox gloves and is not sufficiently well characterized. We have built an apparatus that measures water vapor permeability of elastomers using dilute tritiated water. The technique is more sensitive than other methods currently available and allows us to make measurements on materials and under conditions previously inaccessible. In particular, we present results on laminated drybox gloves for which data is not currently available. (orig.)

  1. Trial Production of Surgical Gloves from Irradiated Natural Rubber Latex on Factory Scale

    Directory of Open Access Journals (Sweden)

    M. Utama

    2005-07-01

    Full Text Available Trial production of surgical gloves from irradiated natural rubber latex at the PT. Laxindo Utama Serang Banten glove factory has been carried out. The variation of heating temperature and leaching time during processing were evaluated. The physical and mechanical properties and the protein allergen respond of surgical gloves using ELISA method were measured. The results showed that the physical and mechanical of surgical gloves such as tensile strength, modulus, and elongation at break arefound to meet the requirements of the ISO or SNI standard for surgical gloves. While the allergic response through clinical tested latex-sensitive protein allergen known as ELISA test is found to be negative.

  2. Re-usable low density polyethylene arm glove for puerperal ...

    African Journals Online (AJOL)

    Objective: To design a long arm glove that can be used within a puerperal uterus to prevent the health-care worker contracting HIV from an infected patient. The designed long arm glove should be cheap (affordable) and readily available in low resource centres and must have proven sterility assurance and tensile strength ...

  3. Haptic Glove Technology: Skill Development through Video Game Play

    Science.gov (United States)

    Bargerhuff, Mary Ellen; Cowan, Heidi; Oliveira, Francisco; Quek, Francis; Fang, Bing

    2010-01-01

    This article introduces a recently developed haptic glove system and describes how the participants used a video game that was purposely designed to train them in skills that are needed for the efficient use of the haptic glove. Assessed skills included speed, efficiency, embodied skill, and engagement. The findings and implications for future…

  4. THE INFLUENCE OF FATLIQOURING PROCESS ON PROTECTIVE CHARACTERISTICS OF LEATHER GLOVES

    Directory of Open Access Journals (Sweden)

    KILIÇ Eylem

    2017-05-01

    Full Text Available Appropriate protective gloves are essential for industry workers to avoid hands and wrists injuries. Leather is a common material used by professionals for technical gloves. Mechanical resistance, protection against water and high temperature has to be fulfilled by leather that is intended for using in protective gloves. In this study recipes using various fatliquoring agents with different properties such as lesitin based, lanolin based, polymeric based and water proofing fat liquor were applied to produce technical glove leather and effect of each fatliquoring product on protective performance of leathers were analyzed in terms of physical and mechanical properties including tensile (ISO 3376, stitch tear (ISO 23910, tear resistance (ISO 3377-2, static (ISO 2417 and dynamicwater absorption (ISO 5403-1 and thermal stability such as dry heat (ISO 17227 and heat stability (ISO 11645. For this purpose, chromium tanned split calf leathers were used and retanning of protective leather gloves were performed by using tara and phosphonium combination. Performance testing results obtained from four different retanning processes was compared according to the type of fatliquoring material used in the production. Post-tanning with different types of fatliquoring products have significant effect on the protective performance properties of leather gloves, in terms of mechanical and thermal properties.

  5. Design innovation for the management of alpha contaminated unserviceable glove boxes

    International Nuclear Information System (INIS)

    Devendra Sandhanshive; Shivaji Shendge; SK Pol; KNS Nair; PK Wattal; IA Sarjekhan, Arun Kumar

    2013-01-01

    With the maturing of nuclear industry, there is an added burden on the Back End of fuel cycle. Radioactive facilities are in the need for refurbishment. This paper describes the steps adopted for managing such alpha contaminated unserviceable Glove Boxes. The first step consisted of in-situ encasement of individual Glove Boxes, encountering the challenges of low head room and space congestion in these laboratories with cognizance to regulatory requirement related to radiation safety. The second step was removal, transfer and placement of encased Glove Boxes in a dedicated facility under continuous surveillance. The glove boxes will remain stored in this facility until arrangements are completed for dismantling and volume reduction in another facility dedicated for this purpose. The final step is the development of an appropriate technique for dismantling/cutting of Glove Boxes in an alpha-tight facility constructed to prevent spread of airborne activity, collection of cut pieces, subsequent decontamination of these metallic wastes and disposal. The paper describes the design scheme for dismantling of the glove box. The description also includes hands on evaluation of tools and gadgets in pilot set-up with a view to incorporating the most credible choice in an upcoming active facility. (authors)

  6. The Short-term Protective Effects of 'Non-PPE' Gloves Used by Greenhouse Workers.

    Science.gov (United States)

    Roff, Martin

    2015-10-01

    Task-based worker exposure assessments are used in regulatory product approval for pesticides. Some agricultural workers may be exposed to pesticide residues predominantly via transfer to the hands during plant tending or crop harvesting. They may use thin 'splash-resistant single-use' (SRSU) gloves or cotton gloves as good industry practice, for example, to protect a delicate crop from bruising, rather than specifically for chemical protection. These 'non-personal protective equipment (PPE)' gloves may or may not have been tested for chemical resistance, but can nevertheless give limited protection from chemicals. This paper reports experiments to assess the protection factors (PFs) of 'non-PPE' gloves against chemicals, to better inform the regulatory exposure assessments.One type of lightweight cotton and three types of 0.1 mm SRSU gloves 25cm long (latex, nitrile, and vinyl) that might be used as 'non-PPE' gloves and one type of 0.4 mm PPE nitrile gauntlet 33cm long were worn by 36 volunteers in greenhouses at four nurseries, handling plants sprayed with transferable but non-permeating strontium acetate in four consecutive 1-h sessions, including one session in which no gloves were worn. Dislodgeable foliar residues were measured by rinsing leaves in bags. Each subject carried out their task such as weeding or trimming, for their four sessions on their set of plants. Handwashes followed each session, and the washings were sampled and analysed for strontium. Unprotected hand contamination was taken to be the within-subject 'challenge' in the absence of gloves. It ranged from 166 to 4091 µg equivalent of strontium acetate on the hands and increased with increasing foliar residues. Geometric mean PFs were 60 (95% CI 38-87, n = 22) for PPE gauntlets, 32 (25-41, n = 65) for SRSU gloves and 5.3 (3.5-8, n = 21) for lightweight cotton. The PFs offered by the waterproof gloves (gauntlets and SRSU) increased with challenge, but for the absorbent cotton gloves it

  7. Comfort and performance of power line maintainers' gloves during electrical utility work in the cold.

    Science.gov (United States)

    Hunt, S; Boyle, C; Wells, R

    2014-01-01

    Electrical utility workers wear thick rubber gloves and often work in the cold. To document the challenge of working in the cold and the effectiveness of different glove/liner combinations in keeping workers' hands warm. Ten experienced male electrical utility employees worked in a controlled temperature walk-in chamber at -20 °C for 45 minutes for each of five glove conditions: standard five-finger rubber gloves with cotton liners and gauntlets, mitten style gloves, a prototype wool liner, and two heating options; glove or torso. Dependent measures were maximum grip force, skin temperatures, finger dexterity and sensitivity to touch, ratings of perceived effort and a rating of thermal sensation. Participants' hand skin temperatures decreased, they perceived their hands to be much colder, their finger sensitivity decreased and their ratings of perceived exertion increased, however their performance did not degrade over the 45 minute trials. The mitten-style gloves showed a smaller drop in skin temperature for the 3rd and 5th digits (pglove conditions. Mitten style gloves kept workers' hands warmer than the standard five finger glove.

  8. Retained portion of latex glove during femoral nailing. Case report.

    Science.gov (United States)

    Sadat-Ali, M; Marwah, S; al-Habdan, I

    1996-11-01

    A case of retained glove during Kuntscher intramedullary nailing is described. An abscess around the glove could have lead to osteomyelitis. One need to be cautious feeling the top end of the nail while femoral nailing to avoid such a complication.

  9. Hand Rehabilitation Learning System With an Exoskeleton Robotic Glove.

    Science.gov (United States)

    Ma, Zhou; Ben-Tzvi, Pinhas; Danoff, Jerome

    2016-12-01

    This paper presents a hand rehabilitation learning system, the SAFE Glove, a device that can be utilized to enhance the rehabilitation of subjects with disabilities. This system is able to learn fingertip motion and force for grasping different objects and then record and analyze the common movements of hand function including grip and release patterns. The glove is then able to reproduce these movement patterns in playback fashion to assist a weakened hand to accomplish these movements, or to modulate the assistive level based on the user's or therapist's intent for the purpose of hand rehabilitation therapy. Preliminary data have been collected from healthy hands. To demonstrate the glove's ability to manipulate the hand, the glove has been fitted on a wooden hand and the grasping of various objects was performed. To further prove that hands can be safely driven by this haptic mechanism, force sensor readings placed between each finger and the mechanism are plotted. These experimental results demonstrate the potential of the proposed system in rehabilitation therapy.

  10. [Identification of migrants from nitrile-butadiene rubber gloves].

    Science.gov (United States)

    Mutsuga, Motoh; Kawamura, Yoko; Wakui, Chiseko; Maitani, Tamio

    2003-04-01

    Polyvinyl chloride gloves containing di(2-ethylhexyl) phthalate are restricted for food contact use. In their place, disposable gloves made from nitrile-butadiene rubber (NBR) are used in contact with foodstuffs. Some unknown substances were found to migrate into n-heptane from NBR gloves. By GC/MS, HR-MS and NMR, their chemical structures were confirmed to be 2,2,4-trimethyl-1,3-pentanediol diisobutyrate (used as a plasticizer), 4,4'-butylidenedi(6-tert-butyl-m-cresol), a mixture of styrenated phenols consisting of 2-(alpha-methylbenzyl)phenol, 4-(alpha-methylbenzyl)phenol, 2,6-di(alpha-methylbenzyl)phenol, 2,4-di(alpha-methylbenzyl)phenol and 2,4,6-tri(alpha-methylbenzyl)phenol (used as antioxidants), and 2,4-di-tert-butylphenol, which seems to a degradation product of antioxidant. Migration levels of these compounds were 1.68 micrograms/cm2 of 2,4-di-tert-butylphenol, 2.80 micrograms/cm2 of 2,2,4-trimethyl-1,3-pentanediol diisobutyrate, 46.08 micrograms/cm2 of styrenated phenols and 4.22 micrograms/cm2 of 4,4'-butylidenedi(6-tert-butyl-m-cresol) into n-heptane, respectively. The content of total styrenated phenols was 6,900 micrograms/g in NBR gloves.

  11. Sensing and Force-Feedback Exoskeleton (SAFE) Robotic Glove.

    Science.gov (United States)

    Ben-Tzvi, Pinhas; Ma, Zhou

    2015-11-01

    This paper presents the design, implementation and experimental validation of a novel robotic haptic exoskeleton device to measure the user's hand motion and assist hand motion while remaining portable and lightweight. The device consists of a five-finger mechanism actuated with miniature DC motors through antagonistically routed cables at each finger, which act as both active and passive force actuators. The SAFE Glove is a wireless and self-contained mechatronic system that mounts over the dorsum of a bare hand and provides haptic force feedback to each finger. The glove is adaptable to a wide variety of finger sizes without constraining the range of motion. This makes it possible to accurately and comfortably track the complex motion of the finger and thumb joints associated with common movements of hand functions, including grip and release patterns. The glove can be wirelessly linked to a computer for displaying and recording the hand status through 3D Graphical User Interface (GUI) in real-time. The experimental results demonstrate that the SAFE Glove is capable of reliably modeling hand kinematics, measuring finger motion and assisting hand grasping motion. Simulation and experimental results show the potential of the proposed system in rehabilitation therapy and virtual reality applications.

  12. Pyrolysis of rubber gloves in integral pyrolysis test plant

    International Nuclear Information System (INIS)

    Norasalwa Zakaria; Mohd Noor Muhd Yunus; Mohd Annuar Assadat Husain; Farid Nasir Ani

    2010-01-01

    Previously, pyrolysis of rubber gloves in laboratory study was described. In order to visualize the practical application of rubber gloves pyrolysis in terms of treating rubber gloves in medical waste, a new test plant was designed and constructed. The semi-continuous test plant was designed to accommodate rubber gloves that were not cut or shredded. The test plant has a capacity of 2kg/ hr and employed auxiliary fuel instead of the conventional electrical power for heating. The concept was based on moving bed reactor, but additional feature of sand jacket feature was also introduced in the design. Pyrolysis of the gloves was conducted at three temperatures, namely 350 degree Celsius, 400 degree Celsius and 450 degree Celsius. Oxygen presents inside of the reactor due to the combined effect of imperfect sealing and suction effect. This study addresses the performance of this test plant covering the time temperature profile, gas evolution profile and product yield. Comparison between the yield of the liquid, gas and char pyrolyzate was made against the laboratory study. It was found that the oil yield was less than the one obtained from bench scale study. Water formation was more pronounced. The presence of the oxygen also altered the tail gas composition but eliminate the sticky nature of solid residue, making it easier to handle. The chemical composition of the oil was determined and the main compounds in the oil were esters and phtalic acid. (author)

  13. Tritium stripping in a nitrogen glove box using palladium/zeolite and SAES St 198 trademark

    International Nuclear Information System (INIS)

    Klien, J.E.; Wermer, J.R.

    1995-01-01

    Glove box clean-up experiments were conducted in a nitrogen glove box using palladium deposited on zeolite (Pd/z) and a SAES St 198 trademark getter as tritium stripping materials. Protium/deuterium samples spiked with tritium were released into a 620 liter glove box to simulate tritium releases in a 10,500 liter glove box. The Pd/z and the SAES St 198 trademark stripper beds produced a reduction in tritium activity of approximately two to three orders of magnitude and glove box clean-up was limited by a persistent background tritium activity level. Attempts to significantly reduce the glove box activity to lower levels without purging were unsuccessful

  14. Study on evaluation of containment capability of glove box under fire accident (2)

    International Nuclear Information System (INIS)

    Abe, Hitoshi; Watanabe, Koji; Tashiro, Shinsuke; Uchiyama, Gunzo

    2007-11-01

    In the MOX fuel fabrication facility, MOX is required to be handled in glove box to sustain containment of MOX into the facility. In case of fire in the facility, the containment capability of glove box may be deteriorated by pyrolysis or combustion of the plastic materials as components of glove box caused by thermal stress from flame. The purpose of this study is to examine pyrolysis and combustion properties of the materials for applying them to quantitative evaluation method for the containment capability of glove box under fire. This report summarize experimental results about the properties under the air condition and investigation of evaluation model for estimating time-course of deteriorating containment capability of glove box under fire. (author)

  15. Human-computer interface glove using flexible piezoelectric sensors

    Science.gov (United States)

    Cha, Youngsu; Seo, Jeonggyu; Kim, Jun-Sik; Park, Jung-Min

    2017-05-01

    In this note, we propose a human-computer interface glove based on flexible piezoelectric sensors. We select polyvinylidene fluoride as the piezoelectric material for the sensors because of advantages such as a steady piezoelectric characteristic and good flexibility. The sensors are installed in a fabric glove by means of pockets and Velcro bands. We detect changes in the angles of the finger joints from the outputs of the sensors, and use them for controlling a virtual hand that is utilized in virtual object manipulation. To assess the sensing ability of the piezoelectric sensors, we compare the processed angles from the sensor outputs with the real angles from a camera recoding. With good agreement between the processed and real angles, we successfully demonstrate the user interaction system with the virtual hand and interface glove based on the flexible piezoelectric sensors, for four hand motions: fist clenching, pinching, touching, and grasping.

  16. Decontamination and reconditioning of the Argonne National Laboratory-West Casting Laboratory alpha glove box

    International Nuclear Information System (INIS)

    Poston, J.W. Jr.; Burke, L.L.

    1998-01-01

    The Casting Laboratory (CL) alpha glove box was used to melt and cast metallic uranium and plutonium fuels as part of the Department of Energy''s Liquid Metal Fast Breeder Reactor Program. This highly contaminated alpha glove box was decontaminated and reconditioned to allow a change in mission. The goal of reconditioning was to install experimental apparatus and to improve contamination control prior to introducing plutonium-238 into the CL glove box. Construction of a glove box containment structure and an increase in room ventilation were required. A temporary breathing air station was provided for personnel protection as well as personnel comfort. The historical contamination levels, the decontamination techniques, and the results of decontamination also are presented. The health physics aspects of the CL alpha glove box project may be applicable to other glove box refurbishment or decommissioning projects

  17. Plutonium glove boxes - metrology and operational states

    International Nuclear Information System (INIS)

    Thyer, A.M.

    2001-01-01

    The main objective was to undertake a literature review in support of NII's ongoing work in improving safety in the nuclear industry to help define suitable standards of cleanliness for plutonium glove boxes. This is to cover the following areas: existing or proposed national/international standards relating to plutonium glove box cleanliness management; practicable metrology options for assessing the plutonium content of glove boxes; any available dose information relating to the operation of modern and 'old design'; current contamination levels of specific significance (i.e. any accepted level in decommissioning/waste terms, typical criticality limits (if available), any box plutonium loadings that are documented with corresponding operator doses etc.); and, techniques for the decontamination of plutonium glove boxes and their relative effectiveness. This should then form the basis of any further development work undertaken by the UK nuclear industry. Main recommendations are as follows: 1) No information could be found in open literature on acceptable levels of contamination in boxes and action levels for cleanup. If these are not available in closed publications the 2) Where possible, the decontamination methods identified should be tested and dose information recorded against each method to allow informed decisions on which is the optimum technique for a particular form of contamination. 3) Consideration should be given to utilisation of metrology options which have the lowest potential for exposure of operators. Preferred options, may be detection from the outside of boxes using hand-held or permanently located radiation detectors, or semi-intrusive methods such as air-ionisation readings which would require one-off installation of detectors in ductwork

  18. Innovative EVA Glove Exoskeleton, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Dexterous performance degradation resulting from donning an extra-vehicular activity (EVA) glove limits the capability of astronauts to perform certain tasks in...

  19. Applications of the PowerGlove for measurement of finger kinematics

    NARCIS (Netherlands)

    van den Noort, J.C.; van Dijk, Kees Joab; Kortier, H.G.; Veltink, Petrus H.; van Beek, N.; Verhagen, R.; Bour, L.J.; Troster, G.; Cantarella, G.

    2014-01-01

    Hand motor control is quite complex and measurement of hand kinematics is therefore of high interest in many fields. A new measurement system based on miniature inertial and magnetic sensors, the PowerGlove, has been developed. In the near future, the PowerGlove will be applied to study finger

  20. Prospective data collection and analysis of perforations and tears of latex surgical gloves during primary endoprosthetic surgeries

    Directory of Open Access Journals (Sweden)

    Zaatreh, Sarah

    2016-12-01

    Full Text Available Introduction: Surgical gloves are used to prevent contamination of the patient and the hospital staff with pathogens. The aim of this study was to examine the actual effectiveness of gloves by examining the damage (perforations, tears to latex gloves during surgery in the case of primary hip and knee prosthesis implantation. Materials and methods: Latex surgical gloves used by surgeons for primary hip and knee replacement surgeries were collected directly after the surgery and tested using the watertightness test according to ISO EN 455-1:2000.Results: 540 gloves were collected from 104 surgeries. In 32.7% of surgeries at least one glove was damaged. Of all the gloves collected, 10.9% were damaged, mainly on the index finger. The size of the perforations ranged from ≤1 mm to over 5 mm. The surgeon’s glove size was the only factor that significantly influenced the occurrence of glove damage. Surgeon training level, procedure duration, and the use of bone cement had no significant influence.Conclusions: Our results highlight the high failure rate of surgical gloves. This has acute implications for glove production, surgical practice, and hygiene guidelines. Further studies are needed to detect the surgical steps, surface structures, and instruments that pose an increased risk for glove damage.

  1. Prospective data collection and analysis of perforations and tears of latex surgical gloves during primary endoprosthetic surgeries.

    Science.gov (United States)

    Zaatreh, Sarah; Enz, Andreas; Klinder, Annett; König, Tony; Mittelmeier, Lena; Kundt, Günther; Mittelmeier, Wolfram

    2016-01-01

    Introduction: Surgical gloves are used to prevent contamination of the patient and the hospital staff with pathogens. The aim of this study was to examine the actual effectiveness of gloves by examining the damage (perforations, tears) to latex gloves during surgery in the case of primary hip and knee prosthesis implantation. Materials and methods: Latex surgical gloves used by surgeons for primary hip and knee replacement surgeries were collected directly after the surgery and tested using the watertightness test according to ISO EN 455-1:2000. Results: 540 gloves were collected from 104 surgeries. In 32.7% of surgeries at least one glove was damaged. Of all the gloves collected, 10.9% were damaged, mainly on the index finger. The size of the perforations ranged from ≤1 mm to over 5 mm. The surgeon's glove size was the only factor that significantly influenced the occurrence of glove damage. Surgeon training level, procedure duration, and the use of bone cement had no significant influence. Conclusions: Our results highlight the high failure rate of surgical gloves. This has acute implications for glove production, surgical practice, and hygiene guidelines. Further studies are needed to detect the surgical steps, surface structures, and instruments that pose an increased risk for glove damage.

  2. Prospective data collection and analysis of perforations and tears of latex surgical gloves during primary endoprosthetic surgeries

    Science.gov (United States)

    Zaatreh, Sarah; Enz, Andreas; Klinder, Annett; König, Tony; Mittelmeier, Lena; Kundt, Günther; Mittelmeier, Wolfram

    2016-01-01

    Introduction: Surgical gloves are used to prevent contamination of the patient and the hospital staff with pathogens. The aim of this study was to examine the actual effectiveness of gloves by examining the damage (perforations, tears) to latex gloves during surgery in the case of primary hip and knee prosthesis implantation. Materials and methods: Latex surgical gloves used by surgeons for primary hip and knee replacement surgeries were collected directly after the surgery and tested using the watertightness test according to ISO EN 455-1:2000. Results: 540 gloves were collected from 104 surgeries. In 32.7% of surgeries at least one glove was damaged. Of all the gloves collected, 10.9% were damaged, mainly on the index finger. The size of the perforations ranged from ≤1 mm to over 5 mm. The surgeon’s glove size was the only factor that significantly influenced the occurrence of glove damage. Surgeon training level, procedure duration, and the use of bone cement had no significant influence. Conclusions: Our results highlight the high failure rate of surgical gloves. This has acute implications for glove production, surgical practice, and hygiene guidelines. Further studies are needed to detect the surgical steps, surface structures, and instruments that pose an increased risk for glove damage. PMID:28066701

  3. PLAY HANDS PROTECTIVE GLOVES: TECHNICAL NOTE ON DESIGN AND CONCEPT.

    Science.gov (United States)

    Houston-Hicks, Michele; Lura, Derek J; Highsmith, M Jason

    2016-09-01

    Cerebral Palsy (CP) is the leading cause of childhood motor disability, with a global incidence of 1.6 to 2.5/1,000 live births. Approximately 23% of children with CP are dependent upon assistive technologies. Some children with developmental disabilities have self-injurious behaviors such as finger biting but also have therapeutic needs. The purpose of this technical note is to describe design considerations for a protective glove and finger covering that maintains finger dexterity for children who exhibit finger and hand chewing (dermatophagia) and require therapeutic range of motion and may benefit from sensory stimulation resulting from constant contact between glove and skin. Protecting Little and Adolescent Youth (PLAY) Hands are protective gloves for children with developmental disorders such as CP who injure themselves by biting their hands due to pain or sensory issues. PLAY Hands will be cosmetically appealing gloves that provide therapeutic warmth, tactile sensory feedback, range of motion for donning/ doffing, and protection to maximize function and quality of life for families of children with developmental disorders. The technology is either a per-finger protective orthosis or an entire glove solution designed from durable 3D-printed biodegradable/bioabsorbable materials such as thermoplastics. PLAY Hands represent a series of protective hand wear interventions in the areas of self-mutilating behavior, kinematics, and sensation. They will be made available in a range of protective iterations from single- or multi-digit finger orthoses to a basic glove design to a more structurally robust and protective iteration. To improve the quality of life for patients and caregivers, they are conceptualized to be cosmetically appealing, protective, and therapeutic.

  4. The Short-term Protective Effects of ‘Non-PPE’ Gloves Used by Greenhouse Workers

    Science.gov (United States)

    Roff, Martin

    2015-01-01

    Task-based worker exposure assessments are used in regulatory product approval for pesticides. Some agricultural workers may be exposed to pesticide residues predominantly via transfer to the hands during plant tending or crop harvesting. They may use thin ‘splash-resistant single-use’ (SRSU) gloves or cotton gloves as good industry practice, for example, to protect a delicate crop from bruising, rather than specifically for chemical protection. These ‘non-personal protective equipment (PPE)’ gloves may or may not have been tested for chemical resistance, but can nevertheless give limited protection from chemicals. This paper reports experiments to assess the protection factors (PFs) of ‘non-PPE’ gloves against chemicals, to better inform the regulatory exposure assessments. One type of lightweight cotton and three types of 0.1 mm SRSU gloves 25cm long (latex, nitrile, and vinyl) that might be used as ‘non-PPE’ gloves and one type of 0.4 mm PPE nitrile gauntlet 33cm long were worn by 36 volunteers in greenhouses at four nurseries, handling plants sprayed with transferable but non-permeating strontium acetate in four consecutive 1-h sessions, including one session in which no gloves were worn. Dislodgeable foliar residues were measured by rinsing leaves in bags. Each subject carried out their task such as weeding or trimming, for their four sessions on their set of plants. Handwashes followed each session, and the washings were sampled and analysed for strontium. Unprotected hand contamination was taken to be the within-subject ‘challenge’ in the absence of gloves. It ranged from 166 to 4091 µg equivalent of strontium acetate on the hands and increased with increasing foliar residues. Geometric mean PFs were 60 (95% CI 38–87, n = 22) for PPE gauntlets, 32 (25–41, n = 65) for SRSU gloves and 5.3 (3.5–8, n = 21) for lightweight cotton. The PFs offered by the waterproof gloves (gauntlets and SRSU) increased with challenge, but for the

  5. Methodology for evaluating gloves in relation to the effects on hand performance capabilities: a literature review.

    Science.gov (United States)

    Dianat, Iman; Haslegrave, Christine M; Stedmon, Alex W

    2012-01-01

    The present study was conducted to review the literature on the methods that have been considered appropriate for evaluation of the effects of gloves on different aspects of hand performance, to make recommendations for the testing and assessment of gloves, and to identify where further research is needed to improve the evaluation protocols. Eighty-five papers meeting the criteria for inclusion were reviewed. Many studies show that gloves may have negative effects on manual dexterity, tactile sensitivity, handgrip strength, muscle activity and fatigue and comfort, while further research is needed to determine glove effects on pinch strength, forearm torque strength and range of finger and wrist movements. The review also highlights several methodological issues (including consideration of both task type and duration of glove use by workers, guidance on the selection and allocation of suitable glove(s) for particular tasks/jobs, and glove design features) that need to be considered in future research. Practitioner Summary: The relevant literature on the effects of protective gloves on different aspects of hand performance was reviewed to make recommendations for the testing and assessment of gloves, and to improve evaluation protocols. The review highlights research areas and methodological issues that need to be considered in future research.

  6. Use of Traditional and Novel Methods to Evaluate the Influence of an EVA Glove on Hand Performance

    Science.gov (United States)

    Benson, Elizabeth A.; England, Scott A.; Mesloh, Miranda; Thompson, Shelby; ajulu, Sudhakar

    2010-01-01

    The gloved hand is one of an astronaut s primary means of interacting with the environment, and any restrictions imposed by the glove can strongly affect performance during extravehicular activity (EVA). Glove restrictions have been the subject of study for decades, yet previous studies have generally been unsuccessful in quantifying glove mobility and tactility. Past studies have tended to focus on the dexterity, strength, and functional performance of the gloved hand; this provides only a circumspect analysis of the impact of each type of restriction on the glove s overall capability. The aim of this study was to develop novel capabilities to provide metrics for mobility and tactility that can be used to assess the performance of a glove in a way that could enable designers and engineers to improve their current designs. A series of evaluations were performed to compare unpressurized and pressurized (4.3 psi) gloved conditions with the ungloved condition. A second series of evaluations were performed with the Thermal Micrometeoroid Garment (TMG) removed. This series of tests provided interesting insight into how much of an effect the TMG has on gloved mobility - in some cases, the presence of the TMG restricted glove mobility as much as pressurization did. Previous hypotheses had assumed that the TMG would have a much lower impact on mobility, but these results suggest that an improvement in the design of the TMG could have a significant impact on glove performance. Tactility testing illustrated the effect of glove pressurization, provided insight into the design of hardware that interfaces with the glove, and highlighted areas of concern. The metrics developed in this study served to benchmark the Phase VI EVA glove and to develop requirements for the next-generation glove for the Constellation program.

  7. Risk of surgical glove perforation in oral and maxillofacial surgery.

    Science.gov (United States)

    Kuroyanagi, N; Nagao, T; Sakuma, H; Miyachi, H; Ochiai, S; Kimura, Y; Fukano, H; Shimozato, K

    2012-08-01

    Oral and maxillofacial surgery, which involves several sharp instruments and fixation materials, is consistently at a high risk for cross-contamination due to perforated gloves, but it is unclear how often such perforations occur. This study aimed to address this issue. The frequency of the perforation of surgical gloves (n=1436) in 150 oral and maxillofacial surgeries including orthognathic surgery (n=45) was assessed by the hydroinsufflation technique. Orthognathic surgery had the highest perforation rate in at least 1 glove in 1 operation (91.1%), followed by cleft lip and palate surgery (55.0%), excision of oral soft tumour (54.5%) and dental implantation (50.0%). The perforation rate in scrub nurses was 63.4%, followed by 44.4% in surgeons and first assistants, and 16.3% in second assistants. The odds ratio for the perforation rate in orthognathic surgery versus other surgeries was 16.0 (95% confidence interval: 5.3-48.0). The protection rate offered by double gloving in orthognathic surgery was 95.2%. These results suggest that, regardless of the surgical duration and blood loss in all fields of surgery, orthognathic surgery must be categorized in the highest risk group for glove perforation, following gynaecological and open lung surgery, due to the involvement of sharp objects. Copyright © 2012 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  8. e of the Surgical Glove in Modified Vacuum-Assisted Wound Healing

    Directory of Open Access Journals (Sweden)

    Shankar Ram Hemmanur

    2013-09-01

    Full Text Available Vacuum-assisted wound healing has been proven to be more efficacious than conventionaldressings. Vacuum dressing has been frequently modified given the restrictions in resourcesavailable. Here we present a modified method of vacuum dressing by using surgical orgynaecological gloves for lower and upper limb wounds. Vacuum dressing was applied withparts of a surgical or gynaecological glove and Opsite with T-tailing of the suction outlet.Vacuum-assisted wound healing using the surgical gloves showed relatively good woundhealing in the amputation stump, finger, arm, and leg in the cases studied.

  9. Design and Dynamic Modeling of Flexible Rehabilitation Mechanical Glove

    Science.gov (United States)

    Lin, M. X.; Ma, G. Y.; Liu, F. Q.; Sun, Q. S.; Song, A. Q.

    2018-03-01

    Rehabilitation gloves are equipment that helps rehabilitation doctors perform finger rehabilitation training, which can greatly reduce the labour intensity of rehabilitation doctors and make more people receive finger rehabilitation training. In the light of the defects of the existing rehabilitation gloves such as complicated structure and stiff movement, a rehabilitation mechanical glove is designed, which provides driving force by using the air cylinder and adopts a rope-spring mechanism to ensure the flexibility of the movement. In order to fit the size of different hands, the bandage ring which can adjust size is used to make the mechanism fixed. In the interest of solve the complex problem of dynamic equation, dynamic simulation is carried out by using Adams to obtain the motion curve, which is easy to optimize the structure of ring position.

  10. Measuring Pu in a glove box using portable NaI and germanium detectors

    International Nuclear Information System (INIS)

    Hankins, D.E.

    1984-01-01

    A NaI crystal or germanium detector inside a portable lead shield can determine the amount of plutonium in a glove box. The number of counts required are defined and the locations outside the box where the detector needs to be positioned are given. The calculated accuracy for measuring the Pu when these locations are used is within +/-30% for most glove boxes. Other factors that may affect this accuracy, such as γ-ray absorption by glove-box materials, self-absorption by Pu, absorption by equipment in the glove box, and the limits of the counting equipment are also discussed

  11. Estimated exposure of hands inside the protective gloves used by non-occupational handlers of agricultural pesticides.

    Science.gov (United States)

    Beránková, Martina; Hojerová, Jarmila; Peráčková, Zuzana

    2017-11-01

    Exposure of handlers'/operators' hands is a main route of agricultural pesticides entry into their body. Non-occupational handlers still lack information about appropriate selection of protective gloves to minimize exposure and reduce adverse effects of these chemicals. According to the results of our previous survey, six commercially available, water-resistant gloves commonly used by non-professional gardeners were evaluated for permeation of Acetamiprid, Pirimicarb, and Chlorpyrifos-methyl (Chlorp-m) pesticides by means of in vitro testing. In-use conditions were mimicked as close as possible. Chlorp-m through latex was observed inside the glove from >10 to ⩽15 min; however, Acetamiprid and Pirimicarb through neoprene/latex and all the three pesticides through butyl were not observed inside gloves for the duration of the experiments (the Breakthrough time (BT)>8 h). The 1-h exposure proved the interior glove contamination with Chlorp-m through disposable latex, vinyl, and nitrile gloves (51, 33, and 41% of applied dose (AD), respectively) just as with Acetamiprid and Pirimicarb through latex glove (11 and 14%AD, respectively). However, when storing the used gloves for 4 days after the exposure, no release of the three pesticides from the butyl and Acetamiprid from neoprene/latex gloves was detected. In all other cases, pesticides were found in the interior glove (36-79, 31-63, and 51-81%AD for Acetamiprid, Pirimicarb, and Chlorp-m, respectively). If used repeatedly, gloves contaminated in this way lose their protective function but give the user a false sense of security. The results suggest that (i) water-resistant gloves are not necessarily pesticide resistant; (ii) disposable latex gloves commonly worn by non-professional gardeners provide inadequate protection even for a short-time contact with pesticides; (iii) to assess the efficiency of reusable gloves, not only BT value but also the reservoir/release effect of parent pesticide and its degradation

  12. Use of Protective Gloves in Nail Salons in Manhattan, New York City.

    Science.gov (United States)

    Basch, Corey; Yarborough, Christina; Trusty, Stephanie; Basch, Charles

    2016-07-01

    Nail salon owners in New York City (NYC) are required to provide their workers with gloves and it is their responsibility to maintain healthy, safe working spaces for their employees. The purpose of this study was to determine the frequency with which nail salon workers wear protective gloves. A Freedom of Information Law request was submitted to New York Department of State's Division of Licensing Services for a full list of nail salons in Manhattan, NYC. A sample population of 800 nail salons was identified and a simple random sample (without replacement) of 30% (n=240) was selected using a random number generator. Researchers visited each nail salon from October to December of 2015, posing as a potential customer to determine if nail salon workers were wearing gloves. Among the 169 salons in which one or more workers was observed providing services, a total of 562 workers were observed. For 149 salons, in which one or more worker was observed providing services, none of the workers were wearing gloves. In contrast, in six of the salons observed, in which one or more workers was providing services, all of the workers (1 in 2 sites, 2 in 1 site, 3 in 2 sites, and 4 in 1 site) were wearing gloves. Almost three-quarters of the total number of workers observed (n=415, 73.8%) were not wearing gloves. The findings of this study indicate that, despite recent media attention and legislation, the majority of nail salon workers we observed were not wearing protective gloves when providing services.

  13. Protective glove use and hygiene habits modify the associations of specific pesticides with Parkinson’s disease

    Science.gov (United States)

    Furlong, Melissa; Tanner, Caroline M; Goldman, Samuel M; Bhudhikanok, Grace S.; Blair, Aaron; Chade, Anabel; Comyns, Kathleen; Hoppin, Jane A.; Kasten, Meike; Korell, Monica; Langston, J William; Marras, Connie; Meng, Cheryl; Richards, Marie; Ross, G Webster; Umbach, David M; Sandler, Dale P; Kamel, Freya

    2014-01-01

    Pesticides have been associated with Parkinson’s disease (PD), and protective gloves and workplace hygiene can reduce pesticide exposure. We assessed whether use of gloves and workplace hygiene modified associations between pesticides and PD. The Farming and Movement Evaluation (FAME) Study is a nested case-control study within the Agricultural Health Study. Use of protective gloves, other PPE, and hygiene practices were determined by questionnaire (69 cases and 237 controls were included). We considered interactions of gloves and hygiene with ever-use of pesticides for all pesticides with ≥ 5 exposed and unexposed cases and controls in each glove-use stratum (paraquat, permethrin, rotenone, and trifluralin). 61% of respondents consistently used protective gloves and 87% consistently used ≥ 2 hygiene practices. Protective glove use modified the associations of paraquat and permethrin with PD: neither pesticide was associated with PD among protective glove users, while both pesticides were associated with PD among non-users (paraquat OR 3.9 [95% CI 1.3, 11.7], interaction p=0.15; permethrin OR 4.3 [95% CI 1.2, 15.6] interaction p=0.05). Rotenone was associated with PD regardless of glove use. Trifluralin was associated with PD among people who used glove use and hygiene practices appeared to be important modifiers of the association between pesticides and PD and may reduce risk of PD associated with certain pesticides. PMID:25461423

  14. Towards understanding the mechanisms and the kinetics of nanoparticle penetration through protective gloves

    International Nuclear Information System (INIS)

    Vinches, L; Boutrigue, N; Zemzem, M; Hallé, S; Peyrot, C; Lemarchand, L; Wilkinson, K J; Tufenkji, N

    2015-01-01

    Parallel to the increased use of engineered nanoparticles (ENP) in the formulation of commercial products or in medicine, numerous health and safety agencies have recommended the application of the precautionary principle to handle ENP; namely, the recommendation to use protective gloves against chemicals. However, recent studies reveal the penetration of titanium dioxide nanoparticles through nitrile rubber protective gloves in conditions simulating occupational use. This project is designed to understand the links between the penetration of gold nanoparticles (nAu) through nitrile rubber protective gloves and the mechanical and physical behaviour of the elastomer material subjected to conditions simulating occupational use (i.e., mechanical deformations (MD) and sweat). Preliminary analyses show that nAu suspensions penetrate selected glove materials after exposure to prolonged (3 hours) dynamic deformations. Significant morphological changes are observed on the outer surface of the glove sample; namely, the number and the surface of the micropores on the surface increase. Moreover, nitrile rubber protective gloves are also shown to be sensitive to the action of nAu suspension and to the action of the saline solution used to simulate sweat (swelling). (paper)

  15. High concentrations of natural rubber latex allergens in gloves used ...

    African Journals Online (AJOL)

    Introduction. Gloves made of natural rubber latex (NRL) are commonly used by healthcare workers because of their good qualities. However, allergic reactions to latex allergens are still commonly reported. Objective. To measure the concentrations of Hev b 1, Hev b 3, Hev b 5 and Hev b 6.02 allergens in gloves used by a ...

  16. Semiautomatic machine for turning inside out industrial leather gloves

    International Nuclear Information System (INIS)

    Aragón-Gonzalez, G; Cano-Blanco, M; León-Galicia, A; Medrano-Sierra, L F; Morales-Gómez, J R

    2015-01-01

    The last step in the industrial leather gloves manufacturing is to turn the inside out so that the sewing be in the inside of the glove. This work presents the design and testing of a machine for that purpose. In order to quantify the relevant variables, testing was performed with a prototype glove. The employed devices and the testing proceeding were developed experimentally. The obtained information was used to build the turning inside out machine. This machine works with pneumatic power to carry the inside out turning by means of double effect lineal actuators. It has two independent work stations that could be operated simultaneously by two persons, one in each station or in single mode operating one station by one person. The turning inside out cycle is started by means of directional control valves operated with pedals. The velocity and developed force by the actuators is controlled with typical pneumatic resources. The geometrical dimensions of the machine are: 1.15 m length; 0.71 m width and 2.15 m high. Its approximated weight is 120 kg. The air consumption is 5.4 fps by each working station with 60 psig work pressure. The turning inside out operation is 40 s for each industrial leather glove

  17. Influence of Glove Type on Mobility Performance for Wheelchair Rugby Players

    NARCIS (Netherlands)

    Mason, Barry S.; van der Woude, L. H. V.; Goosey-Tolfrey, V. L.

    Objective: The purpose of this study was to determine the effectiveness of different glove types on mobility performance in a series of field tests specific to wheelchair rugby. Design: Ten international wheelchair rugby players performed three drills in each glove condition: (i) players' current

  18. Use of Protective Gloves in Nail Salons in Manhattan, New York City

    Directory of Open Access Journals (Sweden)

    Corey Basch

    2016-07-01

    Full Text Available Objectives: Nail salon owners in New York City (NYC are required to provide their workers with gloves and it is their responsibility to maintain healthy, safe working spaces for their employees. The purpose of this study was to determine the frequency with which nail salon workers wear protective gloves. Methods: A Freedom of Information Law request was submitted to New York Department of State’s Division of Licensing Services for a full list of nail salons in Manhattan, NYC. A sample population of 800 nail salons was identified and a simple random sample (without replacement of 30% (n=240 was selected using a random number generator. Researchers visited each nail salon from October to December of 2015, posing as a potential customer to determine if nail salon workers were wearing gloves. Results: Among the 169 salons in which one or more workers was observed providing services, a total of 562 workers were observed. For 149 salons, in which one or more worker was observed providing services, none of the workers were wearing gloves. In contrast, in six of the salons observed, in which one or more workers was providing services, all of the workers (1 in 2 sites, 2 in 1 site, 3 in 2 sites, and 4 in 1 site were wearing gloves. Almost three-quarters of the total number of workers observed (n=415, 73.8% were not wearing gloves. Conclusions: The findings of this study indicate that, despite recent media attention and legislation, the majority of nail salon workers we observed were not wearing protective gloves when providing services.

  19. Detection and toxicity assessment of nitrosamines migration from latex gloves in the Chinese market.

    Science.gov (United States)

    Feng, Di; Wang, Huiping; Cheng, Xuelian; Wang, Jiedong; Ning, Lifeng; Zhou, Qingfeng; Zhou, Yue; Yang, Quanli

    2009-09-01

    Nitrosamines are potent carcinogens and have been found in latex products. In 2007, twenty-seven natural latex gloves including sterile gloves, examination gloves and household use gloves were sampled from the Chinese market. This study monitored the migration of nitrosamines and nitrosatable substance from these gloves, and evaluated their mutagenicity using a Salmonella typhimurium mutation assay (Ames assay) with the strains TA98, TA97, TA100 and TA102 and by a micronucleus test (MN test) using ICR mice. In addition, the cytotoxicity of these compounds was determined by a MTT assay. N-nitrosodimethylamine (NDMA), N-nitrosodiethylamine (NDEA) and N-nitrosodibutylamine (NDBA) were all found in samples treated with artificial sweat for 4h at 37 degrees C, and total nitrosamines varied from 18.89 to 244.51microg/Kg. The nitrosamine mixture of NDMA, NDEA and NDBA was used in both the Ames assay and the MN test. The proportion of NDMA, NDEA and NDBA (1:10:20) was selected according to the proportion of nitrosamines migration from sample E05. In the Ames assay, the lowest dose (1.98 x 10(-3)microg per plate) produced a positive result in the TA98 strain, corresponding to nitrosamines migration from sample E05 of 0.016g (the total nitrosamines migration from glove E05 was 122.55 microg/kg). The TA100 strain responded positively at a dose of 4.96 x 10(-2)microg per plate, corresponding to nitrosamines migration from glove E05 of 0.040g. The MN test showed nitrosamine migration of 3.04 mg from 2066 pairs of sample E05 and could induce micronuclei in one mouse weighing 28g (average weight of one E05 glove was 6g). Extracts from gloves were found to be cytotoxic and there was a significant correlation between cytotoxicity (IC50) and the release level of nitrosamines. In conclusion, in view of the high content of nitrosamines in latex gloves and the potential toxicity of nitrosamines migration from these gloves, it is suggested that both an effective and feasible detection

  20. Development of remote handling tools for glove box

    International Nuclear Information System (INIS)

    Tomita, Yutaka; Nemoto, Takeshi; Denuma, Akio; Todokoro, Akio

    1996-01-01

    For a part of advanced nuclear fuel recycling technology development, we will separate and recover Americium from the MOX fuel scrap by solvent extraction. When we carry this examination, reduction of exposure from Americium-241 is one of important problems. To solve this problem fundamentally, we studied many joints type of the remote handling tools for glove box and produced a trial production machine. Also, we carried out basic function examinations of it. As a result, we got the prospect of development of the remote handling tools which could treat Americium in glove box. (author)

  1. Occupational allergic contact dermatitis caused by sterile non-latex protective gloves: clinical investigation and chemical analyses.

    Science.gov (United States)

    Pontén, Ann; Hamnerius, Nils; Bruze, Magnus; Hansson, Christer; Persson, Christina; Svedman, Cecilia; Thörneby Andersson, Kirsten; Bergendorff, Ola

    2013-02-01

    An increased frequency of occupational contact hand dermatitis among surgical operating theatre personnel has been noticed. To evaluate patients with occupational contact dermatitis caused by their rubber gloves, and to describe a method for analysing the content of the allergens in the gloves. Patch tests were performed with the baseline series, a rubber chemical series, and the patients' own gloves. A method for analysing 1,3-diphenylguanidine (DPG) and cetylpyridinium chloride in the gloves was developed. Contact allergy to thiuram mix was found in 8 of 16 patients, whereas 12 of 16 patients reacted to DPG. In 7 of 8 patients, contact allergy to cetylpyridinium chloride was found. In the patients' gloves, cetylpyridinium chloride and DPG were detected at higher concentrations on the inside of the gloves than on the outside. Most patients had worked for decades in their present occupations, but their hand dermatitis had only been present for months. Contact allergy to DPG in gloves has been disputed, but, in this study, we were able to confirm the presence of DPG and cetylpyridinium chloride in the causative gloves by using a modified method for the analysis. The presence of these chemicals in gloves caused an increase in occupational contact dermatitis in surgical operating theatre personnel. © 2012 John Wiley & Sons A/S.

  2. Disposable gendine antimicrobial gloves for preventing transmission of pathogens in health care settings.

    Science.gov (United States)

    Reitzel, Ruth; Rosenblatt, Joel; Jiang, Ying; Hachem, Ray; Raad, Issam

    2014-01-01

    Transmission of organisms by contact of gloves with surfaces following contact with a pathogen source has been recognized as an important vector for pathogenesis of health care-associated infections. In these cases, the gloves protect the wearer from contact with the pathogenic organisms; however, this personal protection can facilitate the wearer unwittingly becoming a carrier of the pathogens from one location to another. A novel gendine (combination of chlorhexidine and gentian violet) antiseptic coating for the external surface of the glove was developed as a potential intervention to prevent this mode of transmission. We characterized the ability of the coating to rapidly kill bacterial and fungal pathogens within 1 minute of contact with the glove surface. The International Organization of Standardization 22196 concentrated inoculum contact testing methodology was followed. The gendine-coated gloves were able to fully eradicate multidrug-resistant organisms included methicillin-resistant Staphylococcus aureus, vancomycin-resistant enterocci, multidrug-resistant Pseudomonas aeruginosa, and Klebsiella pneumoniae carbapenemase producing. In addition, Candida albicans, Candida glabarata, and 2 pathogenic Escherichia coli strains commonly associated with invasive gastroenteritis were also fully eradicated within 1 minute of contact. The gendine coating did not adversely impact the finish or integrity of the disposable gloves. The highly efficacious gendine-coated antimicrobial gloves potentially provide an additional means of protection against horizontal transmission of common pathogens in a hospital setting. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  3. Gloves and dermal exposure to chemicals: Proposals for evaluating workplace effectiveness

    NARCIS (Netherlands)

    Cherrie, J.W.; Semple, S.; Brouwer, D.

    2004-01-01

    There are standardized laboratory tests for chemical protective gloves that provide estimates of breakthrough time and steady-state permeation flux. However, there is evidence to suggest that these tests may not be completely relevant to glove usage in the workplace. There is no consensus about how

  4. Efficacy of Heated Glove Liners

    National Research Council Canada - National Science Library

    Santee, William

    2000-01-01

    .... It should therefore increase. The issue Light-duty glove (LD), Trigger-finger mitten (TF) and Arctic Mitten (AM), were tested as 2-layer systems at simulated altitudes of sea level, 2500 m and 5000 m in still air and at 5 m s-1 on a biophysical hand model...

  5. Norovirus Transmission between Hands, Gloves, Utensils, and Fresh Produce during Simulated Food Handling

    Science.gov (United States)

    Aho, E.; Mikkelä, A.; Ranta, J.; Tuominen, P.; Rättö, M.; Maunula, L.

    2014-01-01

    Human noroviruses (HuNoVs), a leading cause of food-borne gastroenteritis worldwide, are easily transferred via ready-to-eat (RTE) foods, often prepared by infected food handlers. In this study, the transmission of HuNoV and murine norovirus (MuNoV) from virus-contaminated hands to latex gloves during gloving, as well as from virus-contaminated donor surfaces to recipient surfaces after simulated preparation of cucumber sandwiches, was inspected. Virus transfer was investigated by swabbing with polyester swabs, followed by nucleic acid extraction from the swabs with a commercial kit and quantitative reverse transcription-PCR. During gloving, transfer of MuNoV dried on the hand was observed 10/12 times. HuNoV, dried on latex gloves, was disseminated to clean pairs of gloves 10/12 times, whereas HuNoV without drying was disseminated 11/12 times. In the sandwich-preparing simulation, both viruses were transferred repeatedly to the first recipient surface (left hand, cucumber, and knife) during the preparation. Both MuNoV and HuNoV were transferred more efficiently from latex gloves to cucumbers (1.2% ± 0.6% and 1.5% ± 1.9%) than vice versa (0.7% ± 0.5% and 0.5% ± 0.4%). We estimated that transfer of at least one infective HuNoV from contaminated hands to the sandwich prepared was likely to occur if the hands of the food handler contained 3 log10 or more HuNoVs before gloving. Virus-contaminated gloves were estimated to transfer HuNoV to the food servings more efficiently than a single contaminated cucumber during handling. Our results indicate that virus-free food ingredients and good hand hygiene are needed to prevent HuNoV contamination of RTE foods. PMID:24951789

  6. Development of a test method for protective gloves against nanoparticles in conditions simulating occupational use

    International Nuclear Information System (INIS)

    Dolez, Patricia; Vinches, Ludwig; Vu-Khanh, Toan; Wilkinson, Kevin; Plamondon, Philippe

    2011-01-01

    Nanoparticle manufacture and use are in full expansion. The associated risks of occupational exposure raise large concerns due to their potential toxicity. Even if they stand as a last resort in the traditional occupational Health and Safety (H and S) risk management strategy, personal protective equipment (PPE) against nanoparticles are an absolute need in the context of precautionary principle advocated by H and S organizations worldwide. However no standard test method is currently available for evaluating the efficiency of PPE against nanoparticles, in particular in the case of gloves. A project is thus underway to develop a test method for measuring nanoparticle penetration through protective gloves in conditions simulating glove-nanoparticle occupational interaction. The test setup includes an exposure and a sampling chamber separated by a circular glove sample. A system of cylinders is used to deform the sample while it is exposed to nanoparticles. The whole system is enclosed in a glove box to ensure the operator safety during assembly, dismounting and clean-up operations as well as during the tests. Appropriate nanoparticle detection techniques were also identified. Results are reported here for commercial 15nm TiO2 nanoparticles - powder and colloidal solutions in 1,2-propanediol, ethylene glycol and water - and four types of protective gloves: disposable nitrile and latex as well as unsupported neoprene and butyl rubber gloves. They show that mechanical deformations and contact with colloidal solution liquid carriers may affect glove materials. Preliminary results obtained with TiO2 powder indicate a possible penetration of nanoparticles through gloves following mechanical deformations.

  7. Development of a test method for protective gloves against nanoparticles in conditions simulating occupational use

    Energy Technology Data Exchange (ETDEWEB)

    Dolez, Patricia; Vinches, Ludwig; Vu-Khanh, Toan [Ecole de technologie superieure, 1100 rue Notre-Dame Ouest, Montreal QC H3C 1K3 (Canada); Wilkinson, Kevin [Universite de Montreal, C.P. 6128, succ. Centre-ville Montreal QC H3C 3J7 (Canada); Plamondon, Philippe, E-mail: patricia.dolez@etsmtl.ca [Ecole polytechnique, C.P. 6079, succ. Centre-ville, Montreal QC H3C 3A7 (Canada)

    2011-07-06

    Nanoparticle manufacture and use are in full expansion. The associated risks of occupational exposure raise large concerns due to their potential toxicity. Even if they stand as a last resort in the traditional occupational Health and Safety (H and S) risk management strategy, personal protective equipment (PPE) against nanoparticles are an absolute need in the context of precautionary principle advocated by H and S organizations worldwide. However no standard test method is currently available for evaluating the efficiency of PPE against nanoparticles, in particular in the case of gloves. A project is thus underway to develop a test method for measuring nanoparticle penetration through protective gloves in conditions simulating glove-nanoparticle occupational interaction. The test setup includes an exposure and a sampling chamber separated by a circular glove sample. A system of cylinders is used to deform the sample while it is exposed to nanoparticles. The whole system is enclosed in a glove box to ensure the operator safety during assembly, dismounting and clean-up operations as well as during the tests. Appropriate nanoparticle detection techniques were also identified. Results are reported here for commercial 15nm TiO2 nanoparticles - powder and colloidal solutions in 1,2-propanediol, ethylene glycol and water - and four types of protective gloves: disposable nitrile and latex as well as unsupported neoprene and butyl rubber gloves. They show that mechanical deformations and contact with colloidal solution liquid carriers may affect glove materials. Preliminary results obtained with TiO2 powder indicate a possible penetration of nanoparticles through gloves following mechanical deformations.

  8. Development of a test method for protective gloves against nanoparticles in conditions simulating occupational use

    Science.gov (United States)

    Dolez, Patricia; Vinches, Ludwig; Wilkinson, Kevin; Plamondon, Philippe; Vu-Khanh, Toan

    2011-07-01

    Nanoparticle manufacture and use are in full expansion. The associated risks of occupational exposure raise large concerns due to their potential toxicity. Even if they stand as a last resort in the traditional occupational Health & Safety (H&S) risk management strategy, personal protective equipment (PPE) against nanoparticles are an absolute need in the context of precautionary principle advocated by H&S organizations worldwide. However no standard test method is currently available for evaluating the efficiency of PPE against nanoparticles, in particular in the case of gloves. A project is thus underway to develop a test method for measuring nanoparticle penetration through protective gloves in conditions simulating glove-nanoparticle occupational interaction. The test setup includes an exposure and a sampling chamber separated by a circular glove sample. A system of cylinders is used to deform the sample while it is exposed to nanoparticles. The whole system is enclosed in a glove box to ensure the operator safety during assembly, dismounting and clean-up operations as well as during the tests. Appropriate nanoparticle detection techniques were also identified. Results are reported here for commercial 15nm TiO2 nanoparticles - powder and colloidal solutions in 1,2-propanediol, ethylene glycol and water - and four types of protective gloves: disposable nitrile and latex as well as unsupported neoprene and butyl rubber gloves. They show that mechanical deformations and contact with colloidal solution liquid carriers may affect glove materials. Preliminary results obtained with TiO2 powder indicate a possible penetration of nanoparticles through gloves following mechanical deformations.

  9. A new method of ergonomic testing of gloves protecting against cuts and stabs during knife use.

    Science.gov (United States)

    Irzmańska, Emilia; Tokarski, Tomasz

    2017-05-01

    The paper presents a new method of ergonomic evaluation of gloves protecting against cuts and stabs during knife use, consisting of five manual dexterity tests. Two of them were selected based on the available literature and relevant safety standards, and three were developed by the authors. All of the tests were designed to simulate occupational tasks associated with meat processing as performed by the gloved hand in actual workplaces. The tests involved the three most common types of protective gloves (knitted gloves made of a coverspun yarn, metal mesh gloves, and metal mesh gloves with an ergonomic polyurethane tightener) and were conducted on a group of 20 males. The loading on the muscles of the upper limb (adductor pollicis, flexor carpi ulnaris, flexor carpi radialis, and biceps brachii) was measured using surface electromyography. For the obtained muscle activity values, correlations were found between the glove type and loading of the upper limb. ANOVA showed that the activity of all muscles differed significantly between the five tests. A relationship between glove types and electromyographic results was confirmed at a significance level of α = 0.05. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Investigation of incidence and risk factors for surgical glove perforation in small animal surgery.

    Science.gov (United States)

    Hayes, Galina M; Reynolds, Deborah; Moens, Noel M M; Singh, Ameet; Oblak, Michelle; Gibson, Thomas W G; Brisson, Brigitte A; Nazarali, Alim; Dewey, Cate

    2014-05-01

    To identify incidence and risk factors for surgical glove perforation in small animal surgery. Observational cohort study. Surgical gloves (n = 2132) worn in 363 surgical procedures. All gloves worn by operative personnel were assessed for perforation at end-procedure using a water leak test. Putative risk factors were recorded by a surgical team member. Associations between risk factors and perforation were assessed using multivariable multi-level random-effects logistic regression models to control for hierarchical data structure. At least 1 glove perforation occurred in 26.2% of procedures. Identified risk factors for glove perforation included increased surgical duration (surgery >1 hour OR = 1.79, 95% CI = 1.12-2.86), performing orthopedic procedures (OR = 1.88; 95% CI = 1.23-2.88), any procedure using powered instruments (OR = 1.93; 95% CI = 1.21-3.09) or surgical wire (OR = 3.02; 95% CI = 1.50-6.05), use of polyisoprene as a glove material (OR = 1.59, 95% CI = 1.05-2.39), and operative role as primary surgeon (OR = 2.01; 95% CI = 1.35-2.98). The ability of the wearer to detect perforations intraoperatively was poor, with a sensitivity of 30.8%. There is a high incidence of unrecognized glove perforations in small animal surgery. © Copyright 2014 by The American College of Veterinary Surgeons.

  11. Indigenous development of a glove box for ICP-OES

    International Nuclear Information System (INIS)

    Khan, A.M.; Anwar, M.K.; Bangash, M.A.

    2011-01-01

    Chemical analysis involving nuclear materials are bound to be carried out in safety enclosures like glove box, fume hood etc. whereas chemical analysis which produce mist or vapors of these materials like Atomic absorption Spectrometry, Flame photometry and ICP-AE spectrometry etc. must be performed in a glove box with HEPA filters on exhaust. These instruments with glove box adaptation are rare and impossible to import for our country. An ICP-OES, model Integra-XL of GBC-Australia was purchased in 2008 for chemical analysis of similar materials. As usual it was manufactured to operate in open atmosphere. The required analytical work could not be done in open atmosphere due to active nature of the samples. Therefore modification and glove box (GB) adaptation was required. Although large in size yet difficult to adapt for GB, the instrument had to be modified to a large extent as only sample handling part of the instrument had to placed inside GB, leaving rest of the instrument available for later repair/maintenance work. Different options were considered for modification keeping in mind the isolation and negative pressure inside the GB and maintaining the integrity of the instrument. One of such option was finalized which involved shifting the optic tank etc. A no of isolation gadgets were designed and fabricated locally. This indigenization has saved some handsome amount of foreign exchange. (Author)

  12. The Effects of Industrial Protective Gloves and Hand Skin Temperatures on Hand Grip Strength and Discomfort Rating.

    Science.gov (United States)

    Ramadan, Mohamed Z

    2017-12-04

    Daily working activities and functions require a high contribution of hand and forearm muscles in executing grip force. To study the effects of wearing different gloves on grip strength, under a variety of hand skin temperatures, an assessment of the maximum grip strength was performed with 32 healthy male workers with a mean age (standard deviation) of 30.44 (5.35) years wearing five industrial gloves at three hand skin temperatures. Their ages and anthropometric characteristics including body mass index (BMI), hand length, hand width, hand depth, hand palm, and wrist circumference were measured. The hand was exposed to different bath temperatures (5 °C, 25 °C, and 45 °C) and hand grip strength was measured using a Jamar hydraulic hand dynamometer with and without wearing the gloves (chemical protection glove, rubber insulating glove, anti-vibration impact glove, cotton yarn knitted glove, and RY-WG002 working glove). The data were analyzed using the Shapiro-Wilk test, Pearson correlation coefficient, Tukey test, and analysis of variance (ANOVA) of the within-subject design analysis. The results showed that wearing gloves significantly affected the maximum grip strength. Wearing the RY-WG002 working glove produced a greater reduction on the maximum grip when compared with the bare hand, while low temperatures (5 °C) had a significant influence on grip when compared to medium (25 °C) and high (45 °C) hand skin temperatures. In addition, participants felt more discomfort in both environmental extreme conditions. Furthermore, they reported more discomfort while wearing neoprene, rubber, and RY-WG002 working gloves.

  13. High Pressure EVA Glove (HPEG), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Final Frontier Design's (FFD) High Pressure EVA Glove (HPEG) is a game changing technology enabling future exploration class space missions. The high operating...

  14. A powder-free surgical glove bag for retraction of the gallbladder during laparoscopic cholecystectomy.

    Science.gov (United States)

    Holme, Jørgen Bendix; Mortensen, Frank Viborg

    2005-08-01

    To test the use of a simple and cheap powder-free glove bag to extract the gallbladder during laparoscopic cholecystectomy (LC). The medical records of 142 consecutive patients who had their gallbladder removed using a powder-free glove bag were reviewed. No complications in the form of bile or stone spillage during extraction were observed. The absence of complications and the low cost make routine use of the glove bag a wise option for extracting the gallbladder during LC. The use of the glove bag seems to reduce the risk of contamination with bacteria, bile, and gallstones and may reduce contamination by malignant cells in case of unexpected gallbladder carcinoma.

  15. The Effects of Extravehicular Activity (EVA) Glove Pressure on Hand Strength

    Science.gov (United States)

    Mesloh, Miranda; England, Scott; Benson, Elizabeth; Thompson, Shelby; Rajulu, Sudhakar

    2010-01-01

    The purpose of this study was to characterize hand strength, while wearing a Phase VI Extravehicular Activity (EVA) glove in an Extravehicular Mobility Unit (EMU) suit. Three types of data were collected: hand grip, lateral pinch, and pulp-2 pinch, wider three different conditions: bare-handed, gloved with no Thermal Micrometeoroid Garment (TMG), and glove with TMG. In addition, during the gloved conditions, subjects were tested when unpressurized and pressurized (43 psi). As a percentage of bare-hand strength, the TMG condition showed reduction in grip strength to 55% unpressurized and 46% pressurized. Without the TMG, grip strength increased to 66% unpressurized and 58% pressurized of bare-hand strength. For lateral pinch strength, the reduction in strength was the same for both pressure conditions and with and without the TMG, about 8.5% of bare-hand Pulp-2 pinch strength with no TMG showed an increase to 122% unpressurized and 115% pressurized of bare-hand strength. While wearing the TMG, pulp-2 pinch strength was 115% of bare-hand strength for both pressure conditions.

  16. Citizen's Petition to Food and Drug Administration to ban cornstarch powder on medical gloves: Maltese cross birefringence.

    Science.gov (United States)

    Edlich, Richard F; Long, William B; Gubler, K Dean; Rodeheaver, George T; Thacker, John G; Borel, Lise; Chase, Margot E; Cross, Catherine L; Fisher, Allyson L; Lin, Kant Y; Cox, Mary J; Zura, Robert B

    2009-02-01

    During the last 25 years, scientific experimental and clinical studies have documented the dangers of cornstarch powder on examination and surgical gloves because the cornstarch promotes wound infection, causes serious peritoneal adhesions and granulomatous peritonitis, and is a well-documented vector of the latex allergy epidemic in the world. Realizing the dangers of cornstarch on examination and surgical gloves, Germany's regulations of personal protective equipment banned the use of surgical glove powder cornstarch in 1997. In 2000, the Purchasing and Supply agency for the United Kingdom ceased to purchase any gloves lubricated with cornstarch. Realizing the dangers of cornstarch-powdered gloves, many hospitals and clinics in the United States have banned the use of cornstarch-powdered examination and surgical gloves. Hospitals that have banned cornstarch in their examination and surgical gloves have noted a marked reduction in the latex allergy epidemic in their facilities. Realizing the dangers of cornstarch-powdered examination and surgical gloves, Dr Sheila A. Murphey, branch chief, Infection Control Devices Branch, Division of Anesthesiology, General Hospital, Infection Control, and Dental Devices Office of Device Evaluation, Center for Devices and Radiological Health of the Food and Drug Administration (FDA), recommended that a Citizen's Petition be filed to the FDA to ban cornstarch on surgical and examination gloves. The 12 authors of this report have attached the enclosed petition to the FDA to ban the use of cornstarch on all synthetic and latex examination and surgical gloves used in the United States.

  17. The Effects of Industrial Protective Gloves and Hand Skin Temperatures on Hand Grip Strength and Discomfort Rating

    Directory of Open Access Journals (Sweden)

    Mohamed Z. Ramadan

    2017-12-01

    Full Text Available Daily working activities and functions require a high contribution of hand and forearm muscles in executing grip force. To study the effects of wearing different gloves on grip strength, under a variety of hand skin temperatures, an assessment of the maximum grip strength was performed with 32 healthy male workers with a mean age (standard deviation of 30.44 (5.35 years wearing five industrial gloves at three hand skin temperatures. Their ages and anthropometric characteristics including body mass index (BMI, hand length, hand width, hand depth, hand palm, and wrist circumference were measured. The hand was exposed to different bath temperatures (5 °C, 25 °C, and 45 °C and hand grip strength was measured using a Jamar hydraulic hand dynamometer with and without wearing the gloves (chemical protection glove, rubber insulating glove, anti-vibration impact glove, cotton yarn knitted glove, and RY-WG002 working glove. The data were analyzed using the Shapiro–Wilk test, Pearson correlation coefficient, Tukey test, and analysis of variance (ANOVA of the within-subject design analysis. The results showed that wearing gloves significantly affected the maximum grip strength. Wearing the RY-WG002 working glove produced a greater reduction on the maximum grip when compared with the bare hand, while low temperatures (5 °C had a significant influence on grip when compared to medium (25 °C and high (45 °C hand skin temperatures. In addition, participants felt more discomfort in both environmental extreme conditions. Furthermore, they reported more discomfort while wearing neoprene, rubber, and RY-WG002 working gloves.

  18. Determining Nuclear Fingerprints: Glove Boxes, Radiation Protection, and the International Atomic Energy Agency.

    Science.gov (United States)

    Rentetzi, Maria

    2017-06-01

    In a nuclear laboratory, a glove box is a windowed, sealed container equipped with two flexible gloves that allow the user to manipulate nuclear materials from the outside in an ostensibly safe environment. As a routine laboratory device, it invites neglect from historians and storytellers of science. Yet, since especially the Gulf War, glove boxes have put the interdependence of science, diplomacy, and politics into clear relief. Standing at the intersection of history of science and international history, technological materials and devices such as the glove box can provide penetrating insight into the role of international diplomatic organizations to the global circulation and control of scientific knowledge. The focus here is on the International Atomic Energy Agency. Copyright © 2017 The Author. Published by Elsevier Ltd.. All rights reserved.

  19. MINIMIZING GLOVEBOX GLOVE BREACHES, PART IV: CONTROL CHARTS

    International Nuclear Information System (INIS)

    Cournoyer, Michael E.; Lee, Michelle B.; Schreiber, Stephen B.

    2007-01-01

    At the Los Alamos National Laboratory (LANL) Plutonium Facility, plutonium. isotopes and other actinides are handled in a glovebox environment. The spread of radiological contamination, and excursions of contaminants into the worker's breathing zone, are minimized and/or prevented through the use of glovebox technology. Evaluating the glovebox configuration, the glovebo gloves are the most vulnerable part of this engineering control. Recognizing this vulnerability, the Glovebox Glove Integrity Program (GGIP) was developed to minimize and/or prevent unplanned openings in the glovebox environment, i.e., glove failures and breaches. In addition, LANL implement the 'Lean Six Sigma (LSS)' program that incorporates the practices of Lean Manufacturing and Six Sigma technologies and tools to effectively improve administrative and engineering controls and work processes. One tool used in LSS is the use of control charts, which is an effective way to characterize data collected from unplanned openings in the glovebox environment. The benefit management receives from using this tool is two-fold. First, control charts signal the absence or presence of systematic variations that result in process instability, in relation to glovebox glove breaches and failures. Second, these graphical representations of process variation detennine whether an improved process is under control. Further, control charts are used to identify statistically significant variations (trends) that can be used in decision making to improve processes. This paper discusses performance indicators assessed by the use control charts, provides examples of control charts, and shows how managers use the results to make decisions. This effort contributes to LANL Continuous Improvement Program by improving the efficiency, cost effectiveness, and formality of glovebox operations.

  20. Organophosphorus pesticide exposure in agriculture: effects of temperature, ultraviolet light and abrasion on PVC gloves

    Science.gov (United States)

    ISMAIL, Ismaniza; GASKIN, Sharyn; PISANIELLO, Dino; EDWARDS, John W.

    2017-01-01

    Elbow length PVC gloves are often recommended for protection against organophosphorus pesticide (OP) exposure in agriculture. However, performance may be reduced due to high temperature, UV exposure and abrasion. We sought to assess these impacts for two OPs under normal use and reasonable worst-case scenarios. Glove permeation tests were conducted using ASTM cells with two PVC glove brands at 23°C and 45°C for up to 8 h. Technical grade dichlorvos and formulated diazinon were used undiluted and at application strength. Breakthough of undiluted dichlorvos occurred at both 23°C and 45°C, but only at 45°C for application strength. Breakthrough of diazinon was not achieved, except when undiluted at 45°C. UV-exposed and abraded gloves showed reduced performance, with the effect being approximately two-fold for dichlorvos. Only small differences were noted between glove brands. Extra precautions should be taken when handling concentrated OPs at high temperature, or when using abraded or sunlight-exposed gloves. PMID:29199264

  1. Glove boxes and similar containments

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    According to the present invention a glove box or similar containment is provided with an exhaust system including a vortex amplifier venting into the system, the vortex amplifier also having its main inlet in fluid flow connection with the containment and a control inlet in fluid flow connection with the atmosphere outside the containment. (U.S.)

  2. Object-oriented process dose modeling for glove-box operations

    International Nuclear Information System (INIS)

    Boerigter, S.T.; Fasel, J.H.; Kornreich, D.E.

    1999-01-01

    The Plutonium Facility at Los Alamos National Laboratory (LANL) supports several defense- and non-defense-related missions for the country by performing fabrication, surveillance, and research and development for materials and components that contain plutonium. Most operations occur in rooms with one or more arrays of glove boxes connected to each other via trolley glove boxes. Each room may contain glove boxes dedicated to several different operations or functions. Minimizing the effective dose equivalent (EDE) is a growing concern as a result of steadily allowable dose limits being imposed and a growing general awareness of safety in the workplace. In general, the authors discriminate three components of a worker's total EDE: the primary EDE, the secondary EDE, and background EDE. The immediate sources to which a worker is exposed provide the primary EDE. The secondary EDE results from operations and sources in the same vicinity or room as the worker. The background EDE results from all other sources of radiation, such as natural sources and sources outside of the room. A particular background source of interest is the nuclear materials vault. The distinction between sources inside and outside of a particular room is arbitrary with the underlying assumption that building walls and floors provide significant shielding to justify including sources in other rooms in the background category. An associated paper details the tool that they use to determine the primary and secondary EDEs for all processes of interest in a room containing glove boxes

  3. Effectiveness of interim stage filter in the exhaust system of glove boxes

    International Nuclear Information System (INIS)

    Patre, D.K.; Vangara, H.; Thanamani, S.; Gopalakrishnan, R.K.; Mhatre, Amol M.

    2018-01-01

    All operations in radiochemical laboratories are carried out in containment systems like Glove boxes and Fume hoods. For controlling air contamination two separate air cleaning systems are incorporated. Laboratory has general ventilation system and glove boxes are provided with a negative pressure system (NPS). Glove box exhaust air is passed through three stage filtration systems: in situ, interim and final before discharging to the atmosphere. In addition to the individual HEPA filters of each glove box, there is an interim HEPA filter bank introduced at the laboratory end. This was introduced to reduce a load on main exhaust filter system. Finally the exhaust air is discharged through the final stage HEPA filter located in the filter house through the Stack. The interim HEPA filter bank provides additional protection for the release of particulate activity and reduces load on the final stage filters. In the present work efforts have been put to validate the interim stage filter, which has been introduced, to limit the environmental release

  4. Dismantling of alpha contaminated obsolete installations and glove boxes on the IRMM site in Geel (Belgium)

    International Nuclear Information System (INIS)

    Cretskens, Pieter; Lenie, Koen; Melis, Gustaaf

    2007-01-01

    At the Institute for Reference Materials and Measurements (European commission, Joint Research Centre, IRMM) a dismantling campaign of obsolete installations and glove boxes has been carried out in 2005. There were various reasons for their removal. Some large installations did not meet modern safety standards, other installations were worn out and expected to cause a radioactive contamination risk in the future. The main goal was to create as less waste as possible by extensive contamination checks and by decontamination if necessary. For the glove boxes, decontamination was not possible. A controlled area was set up around the installation to be dismantled in order to prevent spreading of contamination from dust and dirt. This was only possible for the 'minor' contaminated installations. The dismantling campaign of the glove boxes was carried out by using tents of two types depending the contamination inside the glove boxes. The most common glove boxes were dismantled in a tent constructed with hard surfaced polycarbonate plates (ventilated cell). For glove boxes with higher contamination, the same principle was used but with a second 'glove box tent' inside (ventilated glove tent). The purpose of this project was to learn from the experience of this campaign which gave the ability to make estimates of future radioactive waste or classic waste that could be expected from dismantled installations. (authors)

  5. Analysis of Low Speed Stall Aerodynamics of a Swept Wing with Laminar Flow Glove

    Science.gov (United States)

    Bui, Trong T.

    2014-01-01

    Reynolds-Averaged Navier-Stokes (RANS) computational fluid dynamics (CFD) analysis was conducted to study the low-speed stall aerodynamics of a GIII aircraft's swept wing modified with a laminar-flow wing glove. The stall aerodynamics of the gloved wing were analyzed and compared with the unmodified wing for the flight speed of 120 knots and altitude of 2300 ft above mean sea level (MSL). The Star-CCM+ polyhedral unstructured CFD code was first validated for wing stall predictions using the wing-body geometry from the First American Institute of Aeronautics and Astronautics (AIAA) CFD High-Lift Prediction Workshop. It was found that the Star-CCM+ CFD code can produce results that are within the scattering of other CFD codes considered at the workshop. In particular, the Star-CCM+ CFD code was able to predict wing stall for the AIAA wing-body geometry to within 1 degree of angle of attack as compared to benchmark wind-tunnel test data. Current results show that the addition of the laminar-flow wing glove causes the gloved wing to stall much earlier than the unmodified wing. Furthermore, the gloved wing has a different stall characteristic than the clean wing, with no sharp lift drop-off at stall for the gloved wing.

  6. Analysis of Low-Speed Stall Aerodynamics of a Swept Wing with Laminar-Flow Glove

    Science.gov (United States)

    Bui, Trong T.

    2014-01-01

    Reynolds-Averaged Navier-Stokes (RANS) computational fluid dynamics (CFD) analysis was conducted to study the low-speed stall aerodynamics of a GIII aircraft's swept wing modified with a laminar-flow wing glove. The stall aerodynamics of the gloved wing were analyzed and compared with the unmodified wing for the flight speed of 120 knots and altitude of 2300 ft above mean sea level (MSL). The Star-CCM+ polyhedral unstructured CFD code was first validated for wing stall predictions using the wing-body geometry from the First American Institute of Aeronautics and Astronautics (AIAA) CFD High-Lift Prediction Workshop. It was found that the Star-CCM+ CFD code can produce results that are within the scattering of other CFD codes considered at the workshop. In particular, the Star-CCM+ CFD code was able to predict wing stall for the AIAA wing-body geometry to within 1 degree of angle of attack as compared to benchmark wind-tunnel test data. Current results show that the addition of the laminar-flow wing glove causes the gloved wing to stall much earlier than the unmodified wing. Furthermore, the gloved wing has a different stall characteristic than the clean wing, with no sharp lift drop-off at stall for the gloved wing.

  7. Measurement of fractional x-ray absorption for radiation attenuating surgical gloves

    International Nuclear Information System (INIS)

    Nagalakshmi, B.; Sawant, S.G.; Nair, C.P.R.; Joshi, V.D.

    2000-01-01

    It is essential to make use of lead gloves having 0.25 mm lead equivalence only for routine x-ray screening as stipulated by International Commission on Radiological Protection. Such surgical gloves which provide attenuation to the extent of one half value thickness for low energy are very useful for the present trend of special x-ray examinations which are on the increase

  8. A human factors approach towards the design of a new glovebox glove for Los Alamos National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Oka, Jude M. [Los Alamos National Laboratory

    2012-08-06

    Present day glovebox gloves at Los Alamos National Laboratory (LANL) are underdeveloped and ergonomically inaccurate. This problem results in numerous sprain and strain injuries every year for employees who perform glovebox work. In addition to injuries, using the current glovebox glove design also contributes to breaches and contamination. The current glove used today at LANL has several problems: (1) The length of the fingers is incorrect, (2) the web spacing between the fingers is nonexistent, (3) the angles between each digit on the finger are incorrect, (4) the thumb is placed inaccurately, and (5) the length of the hand is incorrect. These problems present a need to correct the current glove design to decrease the risk of injuries, breaches, and contamination. Anthropometrics were researched to help find the best range of hand measurements to fix the current glove design. Anthropometrics is the measure of the human physical variation. Anthropometrics for this study were gathered from the American National Survey (ANSUR) data that was conducted by the U.S Army in 1988. The current glovebox glove uses anthropometrics from the 95th to 105th percentile range which is too large so the new gloves are going to implement data from a smaller range of percentile groups. The 105th percentile range represents measurements that exceed the human population but are needed to fit certain circumstance such as wearing several under gloves within the glovebox gloves. Anthropometrics used in this study include: 105th percentile measurements for joint circumference which was unchanged because the room for under gloves plus ease of hand insertion and extraction is needed, 80th percentile measurements for crotch length to allow workers to reach the web spacing in the glove, 20th percentile measurements for finger length to allow workers to reach the end of the glove, standard 10.5cm hand breadth to allow more room to accommodate under gloves, 45 degrees abduction angle for the

  9. Unwrapping a First Aid Tourniquet From Its Plastic Wrapper With and Without Gloves Worn: A Preliminary Study.

    Science.gov (United States)

    Kragh, John F; Aden, James K; Lambert, Connor D; Moore, Virgil K; Dubick, Michael A

    The purpose of this study was to gather data about unwrapping a packaged limb tourniquet from its plastic wrapper while wearing different types of gloves. Because already unwrapped tourniquets require no time to unwrap, unwrapping data may provide insights into the issue of having tourniquets unwrapped when stowed in a first aid kit of a Serviceperson at war. In a laboratory setting, 36 tests of nine glove groups were performed in which four people, gloved and ungloved, unwrapped tourniquets. Other tourniquets were environmentally exposed for 3 months. All the users successfully unwrapped each tourniquet. Mean times to unwrap by glove group were not significantly different (p = .0961). When mean values of eight experimental groups were compared with that of one control group (i.e., bare hands), results showed no significant difference (p > .07). Mean time was least for bare hands (12 seconds) and most for cold gloves layered under mittens (22 seconds). Among the 36 pairwise comparisons of difference between glove group means, after adjustment for multiple comparisons, no comparison was noted to be statistically significant (p > .052, all 36 pairs). Glove thickness ranged from 0 mm for bare hands to 2.5 mm for cold gloves layered under mittens. By glove group, the thickness-time association was moderate, as tested by linear regression (R2 = 0.6096). The tourniquets exposed to the environment had evidence of rapid photodegradation due to direct exposure to sunlight. Such exposure also destroyed the wrappers. In a preliminary study, different gloves performed similarly when wearers unwrapped a tourniquet from its wrapper. The tourniquet wrappers gave no visible protection from sunlight, and environmental exposure destroyed the wrappers. 2017.

  10. Decommissioning a small glove box

    International Nuclear Information System (INIS)

    Bond, R.D.; McSherry, K.

    1985-11-01

    An account is given of dismantling a fuel fabrication glove box using simple tooling. The fissile content of the box was first measured by several non-destructive techniques. After cleaning, the box was dismantled using hand tools and finally packed for disposal. A record of operator radiation doses, the time taken for each stage of the operation and packing information is given. (author)

  11. Permeation of limonene through disposable nitrile gloves using a dextrous robot hand.

    Science.gov (United States)

    Banaee, Sean; S Que Hee, Shane

    2017-03-28

    The purpose of this study was to investigate the permeation of the low-volatile solvent limonene through different disposable, unlined, unsupported, nitrile exam whole gloves (blue, purple, sterling, and lavender, from Kimberly-Clark). This study utilized a moving and static dextrous robot hand as part of a novel dynamic permeation system that allowed sampling at specific times. Quantitation of limonene in samples was based on capillary gas chromatography-mass spectrometry and the internal standard method (4-bromophenol). The average post-permeation thicknesses (before reconditioning) for all gloves for both the moving and static hand were more than 10% of the pre-permeation ones (P≤0.05), although this was not so on reconditioning. The standardized breakthrough times and steady-state permeation periods were similar for the blue, purple, and sterling gloves. Both methods had similar sensitivity. The lavender glove showed a higher permeation rate (0.490±0.031 μg/cm 2 /min) for the moving robotic hand compared to the non-moving hand (P≤0.05), this being ascribed to a thickness threshold. Permeation parameters for the static and dynamic robot hand models indicate that both methods have similar sensitivity in detecting the analyte during permeation and the blue, purple, and sterling gloves behave similarly during the permeation process whether moving or non-moving.

  12. Permeation of limonene through disposable nitrile gloves using a dextrous robot hand

    Science.gov (United States)

    Banaee, Sean; S Que Hee, Shane

    2017-01-01

    Objectives: The purpose of this study was to investigate the permeation of the low-volatile solvent limonene through different disposable, unlined, unsupported, nitrile exam whole gloves (blue, purple, sterling, and lavender, from Kimberly-Clark). Methods: This study utilized a moving and static dextrous robot hand as part of a novel dynamic permeation system that allowed sampling at specific times. Quantitation of limonene in samples was based on capillary gas chromatography-mass spectrometry and the internal standard method (4-bromophenol). Results: The average post-permeation thicknesses (before reconditioning) for all gloves for both the moving and static hand were more than 10% of the pre-permeation ones (P≤0.05), although this was not so on reconditioning. The standardized breakthrough times and steady-state permeation periods were similar for the blue, purple, and sterling gloves. Both methods had similar sensitivity. The lavender glove showed a higher permeation rate (0.490±0.031 μg/cm2/min) for the moving robotic hand compared to the non-moving hand (P≤0.05), this being ascribed to a thickness threshold. Conclusions: Permeation parameters for the static and dynamic robot hand models indicate that both methods have similar sensitivity in detecting the analyte during permeation and the blue, purple, and sterling gloves behave similarly during the permeation process whether moving or non-moving. PMID:28111415

  13. Risk assessment of accidental exposure of surgeons to blood during orthopedic surgery. Are we safe in surgical gloves?

    Directory of Open Access Journals (Sweden)

    Dariusz Timler

    2014-03-01

    Full Text Available Aim. To analyze tears in sterile surgical gloves used by surgeons in the operating theatre of the Trauma and Orthopedic Surgery Department, Copernicus Memorial Hospital, Łódź, Poland Materials and Method. This study analyzes tears in sterile surgical gloves used by surgeons by ICD-9 and ICD-10 codes. 1,404 gloves were collected from 581 surgical procedures. All gloves were tested immediately following surgery using the test method described in Standard EN455–1 (each glove was inflated with 1,000 ± 50 ml of water and observed for leaks for 2–3 min.. Results. Analysis of tears took into consideration the role of medical personnel (operator, first assistant, second assistant during surgical procedure, the type of procedure according to ICD-9 and ICD-10 codes, and the elective or emergency nature of the procedure. The results of the study show that these factors have a significant influence on the risk of glove tears. Significant differences were observed in tear frequency and tear location depending on the function performed by the surgeon during the procedure. Conclusion. The study proved that the role performed by the surgeon during the procedure (operator, first assistant, second assistant has a significant influence on the risk of glove tearing. The role in the procedure determines exposure to glove tears. Implementing a double gloving procedure in surgical procedures or using single gloves characterized by higher tear resistance should be considered.

  14. A prospective study on the risk of glove fingertip contamination during draping in joint replacement surgery.

    Science.gov (United States)

    Makki, D; Deierl, K; Pandit, A; Trakru, S

    2014-09-01

    The aim of this prospective study was to investigate the risk of contamination of surgical gloves during preparation and draping in joint replacement surgery. During 46 hip and knee replacement procedures, the gloves of orthopaedic consultants (n=5) and registrars (n=3) were assessed for contamination immediately after draping by impression of gloved fingers on blood agar. Contamination was evaluated by the surgeon's grade, the type of procedure, the role of the assistant and the dominance of the hand. A total of 125 pairs of top gloves were examined (79 pairs from registrars and 46 pairs from consultants). Bacterial contamination was isolated on 19 pairs (15.2%) (16 pairs from registrars and 3 pairs from consultants, p=0.04). Coagulase negative staphylococci were the main isolates and contamination was considered low in all cases (1-5 colonies). Contamination was seen more on the dominant hand (16 gloves from dominant hands and 6 from non-dominant hands, p=0.04), on the index finger and thumb. More contaminated gloves were seen in hip arthroplasty procedures (16 pairs from total hip replacements vs 3 pairs from total knee replacements, p=0.02). Contamination of glove fingertips during draping in joint replacement procedures is more likely to occur among junior surgeons, in hip rather than knee arthroplasty procedures and on the dominant hand. It is therefore essential that surgeons of different grades replace gloves used in draping to avoid exposing patients to the risk of infection.

  15. Transmission of MRSA to Healthcare Personnel Gowns and Gloves during Care of Nursing Home Residents

    Science.gov (United States)

    Roghmann, Mary-Claire; Johnson, J. Kristie; Sorkin, John D.; Langenberg, Patricia; Lydecker, Alison; Sorace, Brian; Levy, Lauren; Mody, Lona

    2016-01-01

    Objective To estimate the frequency of MRSA transmission to gowns and gloves worn by healthcare personnel (HCP) interacting with nursing home residents in order to inform infection prevention policies in this setting Design Observational study Setting and Participants Residents and HCP from 13 community-based nursing homes in Maryland and Michigan Methods Residents were cultured for MRSA at the anterior nares and perianal or perineal skin. HCP wore gowns and gloves during usual care activities. At the end of each activity, a research coordinator swabbed the HCP’s gown and gloves. Results 403 residents were enrolled; 113 were MRSA colonized. Glove contamination was higher than gown contamination (24% vs. 14% of 954 interactions, pgloves. We identified high risk activities (OR >1.0, pglove contamination. Conclusions MRSA transmission from MRSA positive residents to HCP gown and gloves is substantial with high contact activities of daily living conferring the highest risk. These activities do not involve overt contact with body fluids, skin breakdown or mucous membranes suggesting the need to modify current standards of care involving the use of gowns and gloves in this setting. PMID:26008727

  16. Functional Fit Evaluation to Determine Optimal Ease Requirements in Canadian Forces Chemical Protective Gloves

    National Research Council Canada - National Science Library

    Tremblay-Lutter, Julie

    1995-01-01

    A functional fit evaluation of the Canadian Forces (CF) chemical protective lightweight glove was undertaken in order to quantify the amount of ease required within the glove for optimal functional fit...

  17. Compression under a mechanical counter pressure space suit glove

    Science.gov (United States)

    Waldie, James M A.; Tanaka, Kunihiko; Tourbier, Dietmar; Webb, Paul; Jarvis, Christine W.; Hargens, Alan R.

    2002-01-01

    Background: Current gas-pressurized space suits are bulky stiff shells severely limiting astronaut function and capability. A mechanical counter pressure (MCP) space suit in the form of a tight elastic garment could dramatically improve extravehicular activity (EVA) dexterity, but also be advantageous in safety, cost, mass and volume. The purpose of this study was to verify that a prototype MCP glove exerts the design compression of 200 mmHg, a pressure similar to the current NASA EVA suit. Methods: Seven male subjects donned a pressure measurement array and MCP glove on the right hand, which was placed into a partial vacuum chamber. Average compression was recorded on the palm, the bottom of the middle finger, the top of the middle finger and the dorsum of the hand at pressures of 760 (ambient), 660 and 580 mmHg. The vacuum chamber was used to simulate the pressure difference between the low breathing pressure of the current NASA space suits (approximately 200 mmHg) and an unprotected hand in space. Results: At ambient conditions, the MCP glove compressed the dorsum of the hand at 203.5 +/- 22.7 mmHg, the bottom of the middle finger at 179.4 +/- 16.0 mmHg, and the top of the middle finger at 183.8 +/- 22.6 mmHg. The palm compression was significantly lower (59.6 +/- 18.8 mmHg, pglove compression with the chamber pressure reductions. Conclusions: The MCP glove compressed the dorsum of the hand and middle finger at the design pressure.

  18. Interventional Angiography: Radiation Protection for the Examiner by using Lead-free Gloves.

    Science.gov (United States)

    Kamusella, Peter; Scheer, Fabian; Lüdtke, Christopher Wilhelm; Wiggermann, Philipp; Wissgott, Christian; Andresen, Reimer

    2017-07-01

    The radiation exposure to unprotected parts of the body requires special attention for the interventional radiologist. During angiographic procedures, hands are exposed to the direct X-ray beam and scattered radiation. The aim of the study was to evaluate the radiation exposure of examiners hand with the use of lead-free X-ray protective gloves in clinical practice in terms of shielding and sense of touch. The aim of the study was to evaluate the radiation exposure of examiners hand with the use of lead-free X-ray protective gloves in clinical practice in terms of shielding and sense of touch. Phantom measurements were conducted in the direct X-ray beam and the area of scattered radiation with and without shielding. Examiner measurements were determined in interventional angiographies in clinical routine of the lower limb in antegrade puncture technique through the femoral artery. In 24 out of 50 interventions, an elastic natural rubber latex glove with lead-free metal shielding against radiation was used. All measurements were performed with a direct dosimeter. After the intervention, an opinion of the examiner was requested for evaluation of the sense of touch. Phantom measurements; when using the protective glove in the direct X-ray beam, a significant increase of the Dose Area Product (DAP) (1084.2-1603.8 mGy*cm 2 ; 67.6%; pgloves were used, a significant increase of the DAP (6183.2-10462.9 mGy*cm 2 ; 59.1%; pgloves is characterized by a shielding effect against X-ray scattered radiation, without restricting the sense of touch. A significant reduction in radiation doses to the examiner can be accomplished with these gloves in the area of scattered radiation only. If the gloves were used in the direct X-ray beam, especially while the artery puncture was performed, a significant increase of the dose values was observed.

  19. Empirical Evidence of Risk and Performance: Top Glove Corporation Berhad

    OpenAIRE

    lim, yu zhi

    2017-01-01

    The purpose of this study is desired to examine the profitability performance of Top Glove Corporation Berhad with some risk factors (liquidity risk, operating risk) and macroeconomic factors. This study was according to the annual report data of Top Glove from year 2011 to year 2015. It shows that there are negative relationship between the company’s profitability and the operating ratio. By using the IBM SPSS Statistics software and add some measurement such as GDP, inflation rate, asset si...

  20. Factors influencing the end of the service life of protective gloves used in car repair shops: a preliminary report.

    Science.gov (United States)

    Emilia, Irzmańska; Agnieszka, Stefko; Katarzyna, Dyńska-Kukulska

    2015-01-01

    The paper presents the results of an end-of-service-life study on 2 kinds of protective gloves designed for workplaces in which workers are exposed to mineral oils and mechanical factors. The authors developed their own end-of-service-life study method that takes into account factors occurring during real-life use of protective gloves. The examined gloves were subjected to mechanical, chemical, and physical factors. The objective of the study was to compare the protective in new gloves subjected to a laboratory simulation test and in gloves used at workplaces in car repair shops. A further goal was to design a glove assessment procedure that would ensure comprehensive analysis of the actual level of performance provided by gloves exposed to selected chemical and mechanical factors as well as subjected to the influence of temperature and humidity, mechanical damage, and chemical degradation of material. The results lead to the conclusion that simultaneous exposure of protective gloves to mechanical, chemical, and physical factors significantly decreases their performance levels. Furthermore, similar performance levels were obtained for gloves subjected to laboratory simulation tests and for those used in the workplace.

  1. Telepresence master glove controller for dexterous robotic end-effectors

    Science.gov (United States)

    Fisher, Scott S.

    1987-01-01

    This paper describes recent research in the Aerospace Human Factors Research Division at NASA's Ames Research Center to develop a glove-like, control and data-recording device (DataGlove) that records and transmits to a host computer in real time, and at appropriate resolution, a numeric data-record of a user's hand/finger shape and dynamics. System configuration and performance specifications are detailed, and current research is discussed investigating its applications in operator control of dexterous robotic end-effectors and for use as a human factors research tool in evaluation of operator hand function requirements and performance in other specialized task environments.

  2. Protective gloves for use in high-risk patients: how much do they affect the dexterity of the surgeon?

    Science.gov (United States)

    Phillips, A. M.; Birch, N. C.; Ribbans, W. J.

    1997-01-01

    Twenty-five orthopaedic surgeons underwent eight motor and sensory tests while using four different glove combinations and without gloves. As well as single and double latex, surgeons wore a simple Kevlar glove with latex inside and outside and then wore a Kevlar and Medak glove with latex inside and outside, as recommended by the manufacturers. The effect of learning with each sequence was neutralised by randomising the glove order. The time taken to complete each test was recorded and, where appropriate, error rates were noted. Simple sensory tests took progressively longer to perform so that using the thickest glove combination led to the completion times being doubled. Error rates increased significantly. Tests of stereognosis also took longer and use of the thickest glove combination caused these tests to take three times as long on average. Error rates again increased significantly. However, prolongation of motor tasks was less marked. We conclude that, armed with this quantitative analysis of sensitivity and dexterity impairment, surgeons can judge the relative difficulties that may be incurred as a result of wearing the gloves against the benefits that they offer in protection. PMID:9135240

  3. Perfuração de Luvas durante Cirurgias Ginecológicas Glove Perforation during Gynecologic Surgeries

    Directory of Open Access Journals (Sweden)

    Eddie Fernando Candido Murta

    2000-05-01

    Full Text Available Objetivo: analisar a incidência de perfuração de luvas cirúrgicas durante atos operatórios ginecológicos. Métodos: estudo prospectivo de 454 luvas usadas em 65 procedimentos utilizando-se o método de pressão de água. Resultados: do total de 454 luvas examinadas, foram verificadas perfurações em 54 (11,9%, sendo estatisticamente significativo o maior número de perfurações em comparação ao grupo controle, uma (1,7% em 60 analisadas (pPurpose: to analyze the frequency of glove perforation during gynecologic surgeries. Methods: a prospective study of 454 gloves used in 65 surgeries by the water pressure method. Results: of a total of 454 gloves, 54 (11.9% had perforations. Comparison with the control group showed p<0.05 (chi² test, 1 (1.7% perforation in 60 gloves tested. Of the total of gloves used in 65 surgeries, 29 (44.6% had perforations, 44 (81% had one perforation and 10 (19% had more than one perforation. The two most common sites of perforations were the index finger, 20 (29.5% and the thumb, 14 (25.9%. Perforation was predominant in the left hand (72.1%. The surgeons were the members of the team with the greatest number of glove perforations. Total hysterectomy was the most frequent surgery in which glove perforations occurred (50% of the cases. Conclusion: the glove perforations occurred with relatively high frequency during gynecologic surgeries. The index finger of the left hand proved to be the most affected region. Among the members of the team, the highest percentage of glove perforations occurred in those of the surgeons. Total hysterectomy had the highest perforation rate.

  4. Variability in surface infrared reflectance of thirteen nitrile rubber gloves at key wavelengths for analysis of captan.

    Science.gov (United States)

    Phalen, R N; Que Hee, Shane S

    2007-02-01

    The aim of this study was to investigate the surface variability of 13 powder-free, unlined, and unsupported nitrile rubber gloves using attenuated total reflection Fourier transform infrared (ATR-FT-IR) spectrophotometry at key wavelengths for analysis of captan contamination. The within-glove, within-lot, and between-lot variability was measured at 740, 1124, 1252, and 1735 cm(-1), the characteristic captan reflectance minima wavelengths. Three glove brands were assessed after conditioning overnight at relative humidity (RH) values ranging from 2 +/- 1 to 87 +/- 4% and temperatures ranging from -8.6 +/- 0.7 to 59.2 +/- 0.9 degrees C. For all gloves, 1735 cm(-1) provided the lowest background absorbance and greatest potential sensitivity for captan analysis on the outer glove surface: absorbances ranged from 0.0074 +/- 0.0005 (Microflex) to 0.0195 +/- 0.0024 (SafeSkin); average within-glove coefficients of variation (CV) ranged from 2.7% (Best, range 0.9-5.3%) to 10% (SafeSkin, 1.2-17%); within-glove CVs greater than 10% were for one brand (SafeSkin); within-lot CVs ranged from 2.8% (Best N-Dex) to 28% (SafeSkin Blue); and between-lot variation was statistically significant (p < or = 0.05) for all but two SafeSkin lots. The RH had variable effects dependent on wavelength, being minimal at 1735, 1252, and 1124 cm(-1) and highest at 3430 cm(-1) (O-H stretch region). There was no significant effect of temperature conditioning. Substantial within-glove, within-lot, and between-lot variability was observed. Thus, surface analysis using ATR-FT-IR must treat glove brands and lots as different. ATR-FT-IR proved to be a useful real-time analytical tool for measuring glove variability, detecting surface humidity effects, and choosing selective and sensitive wavelengths for analysis of nonvolatile surface contaminants.

  5. Latex glove sensitivity amongst diagnostic imaging healthcare personnel: a self-reporting investigation

    International Nuclear Information System (INIS)

    Healy, Jan; Brennan, Patrick C.; Bowden, Julie Anne

    2003-01-01

    The use of latex gloves has risen dramatically among healthcare workers resulting in an increase in the number of workers experiencing reactions to gloves. Little evidence of reactions among Irish healthcare workers is available. The current, self-reporting study investigated the prevalence to latex gloves amongst four professional groups within three Diagnostic Imaging Departments. Prevalence is similar to that demonstrated elsewhere with 18.3% of individuals expressing latex associated symptoms. Symptoms included itching and redness of hands, dry cracked skin, soreness of eyes and upper respiratory tract complaints. These results indicate that latex hypersensitivity is a real problem amongst Irish healthcare workers. This preliminary work provides the basis of a much larger controlled study currently being planned

  6. In-Situ Leak Testing And Replacement Of Glovebox Isolator, Or Containment Unit Gloves

    Science.gov (United States)

    Castro, Julio M.; Macdonald, John M.; Steckle, Jr., Warren P.

    2004-11-02

    A test plug for in-situ testing a glove installed in a glovebox is provided that uses a top plate and a base plate, and a diametrically expandable sealing mechanism fitting between the two plates. The sealing mechanism engages the base plate to diametrically expand when the variable distance between the top plate and the bottom plate is reduced. An inlet valve included on the top plate is used to introducing a pressurized gas to the interior of the glove, and a pressure gauge located on the top plate is used to monitor the interior glove pressure.

  7. Effect of multiple alcohol-based hand rub applications on the tensile properties of thirteen brands of medical exam nitrile and latex gloves.

    Science.gov (United States)

    Gao, Pengfei; Horvatin, Matthew; Niezgoda, George; Weible, Robyn; Shaffer, Ronald

    2016-12-01

    Current CDC guidance for the disinfection of gloved hands during the doffing of personal protective equipment (PPE) following the care of a patient with Ebola recommends for multiple applications of alcohol-based hand rub (ABHR) on medical exam gloves. To evaluate possible effects of ABHR applications on glove integrity, thirteen brands of nitrile and latex medical exam gloves from five manufacturers and two different ABHRs were included in this study. A pair of gloves were worn by a test operator and the outside surfaces of the gloves were separately treated with an ABHR for 1-6 applications. Tensile strength and ultimate elongation of the gloves without any ABHR treatments (control gloves) and gloves after 1-6 ABHR applications were measured based on the ASTM D412 standard method. In general, tensile strength decreased with each ABHR application. ABHRs had more effect on the tensile strength of the tested nitrile than latex gloves, while ethanol-based ABHR (EBHR) resulted in lesser changes in tensile strength compared to isopropanol-based ABHR (IBHR). The results show that multiple EBHR applications on the latex gloves and some of the nitrile gloves tested should be safe for Ebola PPE doffing based on the CDC guidance. Appropriate hospital staff practice using ABHR treatment and doffing gloves is recommended to become more familiar with changes in glove properties.

  8. Prevalence of manufacturing defects in latex examination gloves used in selected dental practices in central Saudi Arabia.

    Science.gov (United States)

    Al-Swuailem, Abdullah S

    2014-07-01

    To assess the defect rates in latex examination gloves used in selected dental practices in Riyadh, Saudi Arabia. In this cross-sectional study, a total of 796 latex examination gloves were collected from 5 governmental hospitals and 5 private dental practices between April 2012 and May 2012. The gloves were assessed for presence of defects visually (VT) and using water inflation test (WIT). One and 2 sample t-tests were used to assess significant differences in defect rates among each latex brand, and between governmental hospitals and private dental practices. Defects in latex gloves were more likely to be identified using WIT compared with VT (20.2% versus 4.3%, p=0.000). Using WIT, examined latex gloves had a defect rate approximately 8 times the acceptable quality level of 2.5% (20.2%, p=0.000). Using WIT, gloves used in private dental practices had significantly higher defect rates compared with governmental dental clinics (25.6% versus 14.6%, p=0.006). Most latex examination gloves used in the sampled governmental dental clinics and private dental practices in Riyadh had significantly higher preexisting defect rates than acceptable standard levels.

  9. Fusion welded fabrication of unshielded steel glove boxes

    International Nuclear Information System (INIS)

    1981-04-01

    This Specification deals with the manufacture, testing, inspection and delivery of fabricated glove boxes, including such internal and/or external fittings as are shown on the relevant drawings. (author)

  10. A soft robotic exomusculature glove with integrated sEMG sensing for hand rehabilitation.

    Science.gov (United States)

    Delph, Michael A; Fischer, Sarah A; Gauthier, Phillip W; Luna, Carlos H Martinez; Clancy, Edward A; Fischer, Gregory S

    2013-06-01

    Stroke affects 750,000 people annually, and 80% of stroke survivors are left with weakened limbs and hands. Repetitive hand movement is often used as a rehabilitation technique in order to regain hand movement and strength. In order to facilitate this rehabilitation, a robotic glove was designed to aid in the movement and coordination of gripping exercises. This glove utilizes a cable system to open and close a patients hand. The cables are actuated by servomotors, mounted in a backpack weighing 13.2 lbs including battery power sources. The glove can be controlled in terms of finger position and grip force through switch interface, software program, or surface myoelectric (sEMG) signal. The primary control modes of the system provide: active assistance, active resistance and a preprogrammed mode. This project developed a working prototype of the rehabilitative robotic glove which actuates the fingers over a full range of motion across one degree-of-freedom, and is capable of generating a maximum 15N grip force.

  11. Bacterial contamination of surgeons' gloves during shunt insertion; a pilot study

    DEFF Research Database (Denmark)

    Sørensen, Preben; Ejlertsen, Tove; Aaen, Dorte

    2008-01-01

    Bacterial infection is a major cause of shunt dysfunction. It is well-known that the majority of pathogenic micro-organisms are low-virulent bacteria normally found on intact skin. Probably shunts become contaminated during surgery either by contact to the patient skin, or contact from contaminated...... gloves or instruments. This study was performed to find out to what extent gloves become contaminated during shunt surgery. Gloves used during shunt implantation were examined in 10 operations. Shunt implantation was done using recommended precautions to avoid infection, including prophylactic...... nurse and assistant were contaminated with micro-organisms less than 15 min after surgery has been commenced and before the shunts were handled. This study offers a feasible, simple and logical explanation of how shunts may become contaminated and infected. A simple measure would be to change the outer...

  12. Study of plutonium fire extinction in glove-boxes

    International Nuclear Information System (INIS)

    Boisson, H.; Chappellier, A.; Debiar, A.; Savornin, J.

    1965-01-01

    The report concerns attempts to extinguish fire in uranium - chosen as a basis for comparison - and in plutonium, these being contained in glove boxes. The extinguishing powders TEC and MG 10 were tried and compared. The operator used in plastic bags. The metal was dealt with respectively in the form of billets, compact chips and finally thin shavings. In each case fire control was without difficulty. One must allow a certain time for cooling. The powder MG 10 showed very good results. Moreover, the trials proved that densely packed shavings are a very real security factor. The interior lay-out of the glove boxes ought, in order to facilitate further manipulations, be such as to render extinction as easy as possible should the need arise. (authors) [fr

  13. Effects of glovebox gloves on grip and key pinch strength and contact forces for simulated manual operations with three commonly used hand tools.

    Science.gov (United States)

    Sung, Peng-Cheng

    2014-01-01

    This study examined the effects of glovebox gloves for 11 females on maximum grip and key pinch strength and on contact forces generated from simulated tasks of a roller, a pair of tweezers and a crescent wrench. The independent variables were gloves fabricated of butyl, CSM/hypalon and neoprene materials; two glove thicknesses; and layers of gloves worn including single, double and triple gloving. CSM/hypalon and butyl gloves produced greater grip strength than the neoprene gloves. CSM/hypalon gloves also lowered contact forces for roller and wrench tasks. Single gloving and thin gloves improved hand strength performances. However, triple layers lowered contact forces for all tasks. Based on the evaluating results, selection and design recommendations of gloves for three hand tools were provided to minimise the effects on hand strength and optimise protection of the palmar hand in glovebox environments. To improve safety and health in the glovebox environments where gloves usage is a necessity, this study provides recommendations for selection and design of glovebox gloves for three hand tools including a roller, a pair of tweezers and a crescent wrench based on the results discovered in the experiments.

  14. Are gloves sufficiently protective when hairdressers are exposed to permanent hair dyes? An in vivo study.

    Science.gov (United States)

    Antelmi, Annarita; Young, Ewa; Svedman, Cecilia; Zimerson, Erik; Engfeldt, Malin; Foti, Caterina; Bruze, Magnus

    2015-04-01

    The use of permanent hair dyes exposes hairdressers to contact allergens such as p-phenylenediamine (PPD), and the preventive measures are insufficient. To perform an in vivo test to study the protective effect of gloves commonly used by hairdressers. Six gloves from Sweden, Italy and Germany were studied: two vinyl, one natural rubber latex, two nitrile, and one polyethylene. The hair dye used for the provocation was a dark shade permanent dye containing PPD. The dye was mixed with hydrogen peroxide, and 8 PPD-sensitized volunteers were tested with the gloves as a membrane between the hair dye and the skin in a cylindrical open chamber system. Three exposure times (15, 30 and 60 min) were used. Eczematous reactions were found when natural rubber latex, polyethylene and vinyl gloves were tested with the dye. The nitrile gloves gave good protection, even after 60 min of exposure to the hair dye. Many protective gloves used by hairdressers are unsuitable for protection against the risk of elicitation of allergic contact dermatitis caused by PPD. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Improvements in or relating to glove boxes or similar containers

    International Nuclear Information System (INIS)

    Strong, R.E.; Boyle, K.; Grant, J.

    1976-01-01

    The glove box described has an extract system that includes a vortex amplifier venting into the system. The main inlet of the vortex amplifier is connected with the containment system and a control inlet is provided in connection with the atmosphere outside the containment system. A variable flow restrictor is provided between the containment system and the extract system, bypassing the vortex amplifier. The arrangement is such that manipulation of a valve is not normally required. The arrangement is not restricted to glove boxes; it can provide an alternative to fume hoods. (U.K.)

  16. Glove box adaptation of oxygen, nitrogen and hydrogen determinator

    International Nuclear Information System (INIS)

    Ramanjaneyulu, P.S.; Phanindra Kumar, M.; Kulkarni, A.S.; Revathi, R.; Saxena, M.K.; Tomar, B.S.

    2017-01-01

    Radioanalytical Chemistry Division (RACD) is involved in chemical quality assurance (CQA) of various nuclear fuels and materials related to various DAE projects including FBTR and PFBR. Determination of oxygen, nitrogen and hydrogen in these fuels is one of the important steps in the CQA of material. For this purpose, O, N and H determinator was indigenously designed, fabricated and commissioned with the help of M/s Chromatography and Instruments Company Ltd., Vadodara, India. The present article describes about glove box adaptation of this instrument and various safety features incorporated in the glove box and instrument at Lab. C-25, RACD, as per the recommendations of the plant level safety committee

  17. Wrist ambulatory monitoring system and smart glove for real time emotional, sensorial and physiological analysis.

    Science.gov (United States)

    Axisa, F; Gehin, C; Delhomme, G; Collet, C; Robin, O; Dittmar, A

    2004-01-01

    Improvement of the quality and efficiency of the quality of health in medicine, at home and in hospital becomes more and more important Designed to be user-friendly, smart clothes and gloves fit well for such a citizen use and health monitoring. Analysis of the autonomic nervous system using non-invasive sensors provides information for the emotional, sensorial, cognitive and physiological analysis. MARSIAN (modular autonomous recorder system for the measurement of autonomic nervous system) is a wrist ambulatory monitoring and recording system with a smart glove with sensors for the detection of the activity of the autonomic nervous system. It is composed of a "smart tee shirt", a "smart glove", a wrist device and PC which records data. The smart glove is one of the key point of MARSIAN. Complex movements, complex geometry, sensation make smart glove designing a challenge. MARSIAN has a large field of applications and researches (vigilance, behaviour, sensorial analysis, thermal environment for human, cognition science, sport, etc...) in various fields like neurophysiology, affective computing and health monitoring.

  18. In-situ dismantling of plutonium-contaminated glove box

    International Nuclear Information System (INIS)

    Numata, Koji; Watanabe, Hisashi; Ishikawa, Hisashi; Miyo, Hiroaki; Ohtsuka, Katsuyuki

    1980-01-01

    A plutonium-contaminated glove box was dismantled along with the development of the treatment techniques for plutonium-bearing wastes. The objectives of this in-situ dismantling of the glove box are to reuse the Plutonium Fuel Fabrication Facility more efficiently, to reduce the volume of wastes generated during the dismantling, and to acquire dismantling techniques for decommissioning the Plutonium Fuel Fabrication Facility in the future. Prior to the dismantling works, a greenhouse for decontamination was installed, and the decontamination with surfactants was performed. Unremovable contamination was coated with paint. After this greenhouse was removed, the main greenhouse for dismantling and three greenhouses for contamination control were assembled. The main workers wearing protective devices engaged in dismantling works in the greenhouse. As the protective devices, anorak type PVC suits with air line masks, Howell type pressurized suits, and respirators were used. The tools used for the dismantling are a plasma cutter, an electric nibbler, an electric disk grinder, an electric circular saw and an electric jig saw. The results of the dismantling in-situ were compared with two previous cases of dismantling carried out by different procedures. In the case of in-situ dismantling, the volume of wastes was 1.6 - 1.8 m 3 /m 3 of glove box, and considerable reduction was realized. (Kako, I.)

  19. PVC posting bags for glove boxes

    International Nuclear Information System (INIS)

    1976-12-01

    This specification covers the materials, measurements and manufacture of unpigmented PVC posting bags for use on glove boxes, together with methods of testing the materials. These bags are used in the handling of radioactive and toxic materials of a hazardous nature and therefore must be of the highest standard of mechanical strength, leak tightness and general finish. (author)

  20. Decontamination of TRU glove boxes

    International Nuclear Information System (INIS)

    Crawford, J.H.

    1978-03-01

    Two glove boxes that had been used for work with transuranic nuclides (TRU) for about 12 years were decontaminated in a test program to collect data for developing a decontamination facility for large equipment highly contaminated with alpha emitters. A simple chemical technique consisting of a cycle of water flushes and alkaline permanganate and oxalic acid washes was used for both boxes. The test showed that glove boxes and similar equipment that are grossly contaminated with transuranic nuclides can be decontaminated to the current DIE nonretrievable disposal guide of <10 nCi TRU/g with a moderate amount of decontamination solution and manpower. Decontamination of the first box from an estimated 1.3 Ci to about 5 mCi (6 nCi/g) required 1.3 gallons of decontamination solution and 0.03 man-hour of work for each square foot of surface area. The second box was decontaminated from an estimated 3.4 Ci to about 2.8 mCi (4.2 nCi/g) using 0.9 gallon of decontamination solution and 0.02 man-hour for each square foot of surface area. Further reductions in contamination were achieved by repetitive decontamination cycles, but the effectiveness of the technique decreased sharply after the initial cycle

  1. Study of Bio-Mimicry Surfaces for Optimization of Coupling Performance in Wheelchair Racing Gloves

    Directory of Open Access Journals (Sweden)

    Clara Usma

    2018-03-01

    Full Text Available In wheelchair racing, the optimal pair of gloves, as well as knowledge of conditioning of glove-rim contact surfaces can have a significant impact on race performance. Extreme temperatures, humidity, wet or dry conditions can considerably influence not only the hand-rim friction coupling (effectiveness of the athlete’s push cycle but also the risk of injuries, blisters or sore areas which in turn, can influence the endurance of the athlete across long distance events. This paper reports an experimental study of the effect of bio-mimicry surface textures as a supplement for heightening glove-rim coupling for dry and wet weather conditions. The paper also provides recommendations for the practical implementation of the study findings through a proposal for the design and development of a pair of bespoke gloves for a wheelchair racing athlete for initial prototyping and performance trials.

  2. A Magnetic Resonance Compatible Soft Wearable Robotic Glove for Hand Rehabilitation and Brain Imaging.

    Science.gov (United States)

    Hong Kai Yap; Kamaldin, Nazir; Jeong Hoon Lim; Nasrallah, Fatima A; Goh, James Cho Hong; Chen-Hua Yeow

    2017-06-01

    In this paper, we present the design, fabrication and evaluation of a soft wearable robotic glove, which can be used with functional Magnetic Resonance imaging (fMRI) during the hand rehabilitation and task specific training. The soft wearable robotic glove, called MR-Glove, consists of two major components: a) a set of soft pneumatic actuators and b) a glove. The soft pneumatic actuators, which are made of silicone elastomers, generate bending motion and actuate finger joints upon pressurization. The device is MR-compatible as it contains no ferromagnetic materials and operates pneumatically. Our results show that the device did not cause artifacts to fMRI images during hand rehabilitation and task-specific exercises. This study demonstrated the possibility of using fMRI and MR-compatible soft wearable robotic device to study brain activities and motor performances during hand rehabilitation, and to unravel the functional effects of rehabilitation robotics on brain stimulation.

  3. Glove use among hairdressers

    DEFF Research Database (Denmark)

    Oreskov, Katia W; Søsted, Heidi; Johansen, Jeanne D

    2015-01-01

    by each person, interrupted by a demonstration of how to use gloves correctly. Photographs were taken to compare UV contamination before and after the demonstration. RESULTS: All of the participants (100%) had their hands contaminated during the first round; the area ranged between 0.02 and 101.37 cm(2......) (median 3.62 cm(2)). In the second round, 55.8% were contaminated (range 0.00-3.08 cm(2) ; median 0.01 cm(2)). The reduction in contaminated skin areas was statistically significant (p 

  4. Perforation of dental gloves during prosthodontic treatments as assessed by the conductivity and water inflation tests.

    Science.gov (United States)

    Nikawa, H; Hamada, T; Tamamoto, M; Abekura, H; Murata, H

    1996-01-01

    The incidence of latex glove perforation during prosthodontic treatment was investigated on 122 occasions using two methods, a conductivity test and a water inflation test. Latex glove perforation was detected in 38.5% of the treatments by the conductivity test and in 27.9% by the water inflation test. The perforation went unrecognized in 74.7% of the occurrences (35/47 incidents) using the conductivity test and in 64.7% (22/34) when the water inflation test was used. Of the total 55 glove perforations, 21 perforations were detected only by conductivity test, 3 were detected only by the water inflation test, and 31 perforations were detected by both methods, which suggested that the conductivity test is more sensitive than the water inflation test for the detection of glove perforation. The results of this research suggested that even when latex gloves are worn, the risk to prosthodontists of exposure to body fluids remains in four of every six treatments, often without the awareness of the prosthodontist.

  5. Latex allergy: assessment of knowledge, appropriate use of gloves and prevention practice among hospital healthcare workers.

    Science.gov (United States)

    Al-Niaimi, F; Chiang, Y Z; Chiang, Y N; Williams, J

    2013-01-01

    Healthcare workers and patients are often exposed to natural rubber latex (NRL) through contact with gloves and various healthcare products, which can potentially cause allergic reactions, with varying degrees of severity. In 2008, the Royal College of Physicians published their first evidence-based guidance on occupational health interventions for latex allergy, which emphasized the importance of healthcare workers having knowledge of latex allergy. This study aimed to survey the knowledge of healthcare workers (n = 156) about latex gloves and NRL allergy, routine prevention practice and the appropriate use of gloves in patient care. Healthcare workers in a large teaching hospital were surveyed using a standard questionnaire. We found that only 1% of healthcare workers were able to correctly match the appropriate gloves to the specifically designed procedure. More than half (n = 74.53%) were unable to recognize the presentation of type 1 allergy to NRL. Of the 156 participants, 131 (84%) considered that they would benefit from training about NRL allergy and the use of different types of gloves in clinical care. This survey indicates the importance of education regarding appropriate use of gloves and prevention of NRL allergy among healthcare workers, and dermatologists should play an important role in facilitating this. © The Author(s). CED © 2012 British Association of Dermatologists.

  6. Preliminary Study on Effect of Chemical Composition Alteration on Elastic Recovery and Stress Recovery of Nitrile Gloves

    Directory of Open Access Journals (Sweden)

    Tan Kai Yang

    2018-01-01

    Full Text Available Nitrile gloves are widely used in the medical and automobile field due to its superiority in hypo-allergic component and chemical resistance over natural latex gloves. However, poor elastic recovery of nitrile glove to compressive force also creates an aesthetic issue for customers with high levels of wrinkling after removing from glove box. This paper demonstrates the preliminary study on the varies chemical composition such as crosslinking agents, sulphur and zinc oxide, the accelerator agent added during curing process, and the rubber filler Titanium Dioxide, on the elastic recovery and stress relaxation in nitrile gloves manufacturing. These chemical were studied at different concentration level comparing the high and low level versus the normal production range. Due to the inconsistency in the analysis technique on the surface imaging, the elastic recovery result was unable to be quantified and was not conclusive at this point. The cross linking agents, sulphur and zinc oxide, and the accelerator agent, played a significant role in the mechanical strength of the gloves. Increment of these chemicals result in higher tensile strength, but a reduction in the elasticity of the materials in which causes a lesser elongation at break percentage for the gloves. Both cross-linkers demonstrate different behaviour where higher sulphur content, provide higher stress relaxation (SR% yet zinc oxide shows otherwise.

  7. Resistance of gloves and protective clothing materials to permeation of cytostatic solutions

    OpenAIRE

    Sylwia Krzemińska; Małgorzata Pośniak; Małgorzata Szewczyńska

    2018-01-01

    Objectives The objective of the work was to determine the resistance of selected protective clothing and glove materials to permeation of cytostatics such as docetaxel, fluorouracil, and doxorubicin. Material and Methods The following glove materials were used: natural rubber latex (code A), acrylonitrile-butadiene rubber (code B) and chloroprene rubber (code C). In addition, we tested a layered material composed of a non-woven polyester (PES), a polypropylene (PP) film, ...

  8. A sealed enclosure of the glove box type

    International Nuclear Information System (INIS)

    Moreels, Pierre.

    1974-01-01

    The invention relates to a sealed enclosure of the glove-box type. According to the invention, the box-frame comprises: angle-bars having a right-angled cross-section, sealing joints, tightening bars and fastening means [fr

  9. Effect of dental tool surface texture and material on static friction with a wet gloved fingertip.

    Science.gov (United States)

    Laroche, Charles; Barr, Alan; Dong, Hui; Rempel, David

    2007-01-01

    Hand injuries are an important cause of pain and disability among dentists and dental hygienists and may be due to the high pinch forces involved in periodontal work. The pinch forces required to perform scaling may be reduced by increasing the friction between the tool and fingers. The purpose of this study was to determine whether modifying the tool material, surface texture, or glove type altered the coefficient of static friction for a wet gloved finger. Seven tools with varying surface topography were machined from 13 mm diameter stainless steel and Delrin and mounted to a 6-component force plate. The textures tested were a fine, medium and coarse diamond knurled pattern and a medium and fine annular pattern (concentric rings). Thirteen subjects pulled their gloved, wet thumb pad along the long axis of the tool while maintaining a normal force of 40 N. Latex and nitrile gloves were tested. The coefficient of static friction was calculated from the shear force history. The mean coefficients of static friction ranged from 0.20 to 0.65. The coefficient of static friction was higher for a smooth tool of Delrin than one of stainless steel. Differences in the coefficient of static friction were observed between the coarse and medium knurled patterns and the fine knurled and annular patterns. Coefficients of static friction were higher for the nitrile glove than the latex glove for tools with texture. These findings may be applied to the design of hand tools that require fine motor control with a wet, gloved hand.

  10. An improved experimental methodology to evaluate the effectiveness of protective gloves against nanoparticles in suspension.

    Science.gov (United States)

    Vinches, Ludwig; Zemzem, Mohamed; Hallé, Stéphane; Peyro, Caroline; Wilkinson, Kevin J; Tufenkji, Nathalie

    2017-07-01

    Recent studies underline the potential health risks associated to the "nano" revolution, particularly for the workers who handle engineered nanoparticles (ENPs) that can be found in the formulation of several commercial products. Although many Health & Safety agencies recommend the use of protective gloves against chemicals, few studies have investigated the effectiveness of these gloves towards nanoparticle suspensions. Moreover, the data that are available are often contradictory. This study was designed to evaluate the effectiveness of protective gloves against nanoparticles in suspension. For this purpose, a new methodology was developed in order to take into account parameters encountered in the workplace such as mechanical deformations (MD) that simulate hand flexion and sweat. The effects of the precise experimental protocol on the concentrations of nanoparticles that were detected in the sampling suspension were assessed. Several samples of nitrile rubber gloves (73 µm thick), taken from different boxes, were brought into contact with gold nanoparticles (5 nm) in water. During their exposure to ENPs, the glove samples submitted systematic mechanical deformations and were placed in contact with a physiological solution simulating human sweat. Under these conditions, results obtained by inductively coupled plasma mass spectrometry (ICPMS) showed that the 5 nm gold nanoparticles passed through the protective gloves. This result was acquired, in spite of the observation of significant losses during the sampling phase that will be important for future experiments evaluating the effectiveness of these materials.

  11. Irradiated latex as an economical raw material for making gloves with a simple technique

    International Nuclear Information System (INIS)

    Utama, Marga

    1983-01-01

    The radiation vulcanization process with stirring method at 3 Mrad irradiation dose has been done. Glove production at ''HOME INDUSTRY'' scale be commercially applied. The physical and mechanical properties, such as modulus, tensile strength, permanent set, and elongation at break, of the gloves can satisfy the standard requirements. (author)

  12. Inactivation of Escherichia coli O157:H7 and Salmonella deposited on gloves in a liquid state and subjected to drying conditions.

    Science.gov (United States)

    Erickson, Marilyn C; Liao, Jye-Yin; Webb, Cathy C; Habteselassie, Mussie Y; Cannon, Jennifer L

    2018-02-02

    Gloves are worn by workers harvesting ready-to-eat produce as a deterrent for contaminating the produce with enteric pathogens that may reside on their hands. As fields are not sterile environments, the probability for gloves to become contaminated still exists and therefore it is critical to understand the conditions that affect the survival of pathogens on gloves. Both Escherichia coli O157:H7 and Salmonella deposited on glove surfaces in a liquid state survived longer when the pathogen had been suspended in lettuce sap than when suspended in water. Despite this protection, pathogens deposited on clean single-use gloves were more likely to survive during drying than pathogens deposited on dirty gloves (a film of lettuce sap had been applied to the surface prior to pathogen application and soil had been ground into the gloves). Survival of both E. coli O157:H7 and Salmonella was biphasic with the greatest losses occurring during the first hour of drying followed by much slower losses in the ensuing hours. Pathogens grown in rich media (tryptic soy broth) versus minimal media (M9) as well as those cultured on solid agar versus liquid broth were also more likely to be resistant to desiccation when deposited onto gloves. Although survival of E. coli O157:H7 on nitrile gloves was in general greater than it was on latex gloves, the relative survival of Salmonella on the two glove types was inconsistent. Due to these inconsistencies, no one glove type is considered better than another in reducing the risk for contamination with enteric pathogens. In addition, the extended survival of what are generally referred to as stress-resistant pathogens suggests that gloves either be changed frequently during the day or washed in a disinfectant to reduce the risk of glove contamination that could otherwise contaminate product handled with the contaminated gloves. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Surgical gloves fabrication using natural rubber latex vulcanized with gamma radiation

    International Nuclear Information System (INIS)

    Collantes, Hugo David Chirinos.

    1995-01-01

    Surgical gloves were manufactured by immersion coagulant method from vulcanized natural rubber latex by gamma rays at dose of 10 kGy in the air, at room temperature, using the following sensitizer vulcanization An-B 3 phr/KOH 0.2 phr. The influence of the parameter in the thickness of the surgical gloves manufacture, studied through fractional factorial designs technic, can be resumed by empirical linear correlation: y = 0.213 + 0.025 [Ca Cl 2 ] + 0.019 t. (author). 49 refs., 13 figs., 31 tabs

  14. THE MANUFACUTE OF GLOVES USING RVNRL: PARAMETERS OF the COAGULANT DIPPING PROCESS

    Directory of Open Access Journals (Sweden)

    H.D. CHIRINOS

    1998-12-01

    Full Text Available Surgical gloves were manufactured using the RVNRL process. A fractional factorial design at two levels showed that five parameters of the coagulant dipping process which were studied independent. Coagulant concentration and dwell time in the radiovulcanized latex presented major main effects while the temperature of the former before dipping into the radiovulcanized latex and the flow time of the radiovulcanized latex on the former surface presented opposite main effects. The withdrawal rate of the former from the radiovulcanized latex did not change glove thickness. The mathematical correlation between the estimates of thickness and the significant main effects of coded variables was = 0.212 + 0.025x1 + 0.019x2. This optimized equation allowed reproduction of a surgical glove thickness in the range of 0.157 to 0.291mm, which is considered acceptable by international standard specification.

  15. Glove box adaptation, installation and commissioning of WD-XRF system for determination of PuO2 in MOX fuel samples

    International Nuclear Information System (INIS)

    Aher, Sachin; Pandey, Ashish; Khan, F.A.; Das, D.K.; Kumar, Surendra; Behere, P.G.; Mohd Afzal

    2015-01-01

    Glove Box facility forms the foremost important confinement system at nuclear fuel fabrication facility for handling of Plutonium based MOX fuels. Due to limited resources of Natural Uranium and maximum utilization of thorium, India has adopted 'Close Fuel Cycle Strategy' which involves use of Plutonium based fuels in Thermal and Fast reactors. Plutonium being radio toxic material with a higher biological half-life, Plutonium based fuel fabrication facility requires special techniques and confinement as a primary method for protection against spreading of powder contamination. Glove Box along with dynamic ventilation and HEPA Filters forms the preeminent facility for safe handling of plutonium based MOX fuels. Various equipment's, systems and instruments associated with MOX fuel production are need to be adapted inside the Glove Box with considerations of safety, ergonomics, accessibility for operations and maintenance, connections of various feed through like electrical connections, gas line supply etc. Quality Control plays the vital role in production of MOX fuels to ensure the finest quality of product to meet the defined specifications of MOX fuels. Presently AFFF is fabricating MOX fuel containing 21% and 28% PuO 2 along with DDUO 2 the first core of PFBR. Precise quantification of PuO 2 in MOX fuel pellets is necessary process control steps after batch preparation in Milling and Mixing operation. At AFFF, WD-XRF is one of the system used for determination of percentage of PuO 2 in MOX fuel batch. Glove Box adaptation of WD-XRF system along with 30 Tones Hydraulic press for sample preparation is being carried out in Type VI and Type IV Glove Boxes connected through transfer tunnel. Due to restrictions of space inside the Glove Box, a special mechanism is developed and installed for safe titling of WD-XRF system inside the Glove Box during the need of maintenance. These Glove Boxes are leak tested by various leak testing technique to meet the

  16. Test of the Fishbein and Ajzen models as predictors of health care workers' glove use.

    Science.gov (United States)

    Levin, P F

    1999-08-01

    The aim of this study was to identify predictors of health care workers' glove use when there is a potential for blood exposure. The study hypothesis was that an extension of the theory of planned behavior would explain more of the variance in glove use behavior than the theory of reasoned action or theory of planned behavior. A random sample of nurses and laboratory workers (N = 527) completed a 26-item questionnaire with acceptable content validity and reliability estimates. Using structural equation modeling techniques, intention, attitude, and perceived risk were significant predictors of behavior. Perceived control and attitude were the significant determinants of intention. The theory of reasoned action was the most parsimonious model, explaining 70% of the variance in glove use behavior. The theory of planned behavior extension was a viable model to study behavior related to glove use and reducing workers' risks to bloodborne diseases.

  17. Design, construction and mounting of a container for transportation and storage of a closed plutonium glove box

    International Nuclear Information System (INIS)

    Aparicio, G.; Insegna, M.A.; Mathot, S.R.; Munoz, C.; Orlando, O.S.; Salguero, D.

    1990-01-01

    With the aim of confining a closed chemistry glove box (with reference to papers: 'Closure of an analytical chemistry glove box in alpha Laboratory' and 'Disconnection and transportation of a closed plutonium glove box to a controlled zone'), it was necessary to design and construct a container to assure transportation from its location (a controlled zone) up to a definitive storage place capable of supporting its posterior confinement. (Author) [es

  18. Disconnection and transport from a controlled zone of a closed plutonium glove box

    International Nuclear Information System (INIS)

    Aparicio, G.; Insegna, M.A.; Mathot, S.R.; Munoz, C.; Orlando, O.S.; Salguero, D.; Toubes, B.

    1990-01-01

    The glove box, to be closed due to the damage caused after 12 operation years in the alpha facility, and following the pertinent vacuum operations and decontamination (described in a previous work 'Closure of an analytical chemistry glove box in alpha-laboratory') must be transported to a transitory storage located in a site inspected by the Development Branch supervised by the Licentiating Branch. (Author) [es

  19. Short and longer duration effects of protective gloves on hand performance capabilities and subjective assessments in a screw-driving task.

    Science.gov (United States)

    Dianat, Iman; Haslegrave, Christine M; Stedmon, Alex W

    2010-12-01

    The study investigated short and longer duration effects of gloves on hand performance capabilities (muscle activity, dexterity, touch sensitivity, finger pinch and forearm torque strength) and subjective assessments of discomfort and ease of manipulation when performing a light assembly task. The independent variables were hand condition with four levels (wearing cotton, nylon or nitrile gloves as well as barehanded) and point of time within the 2 h duration of the task (with measurements taken at 0, 30, 60, 90 and 120 min). Participants worked with a screwdriver to fit two components together using screws. Wearing gloves significantly increased the muscle activity, pinch strength and discomfort but reduced the dexterity and touch sensitivity. There was also a significant effect of task time on the muscle activity, dexterity, forearm torque strength and touch sensitivity, which indicates that the duration of the task should be an important consideration in glove evaluation studies and in the selection of work gloves. STATEMENT OF RELEVANCE: It is important to evaluate the effects of gloves on hand performance capabilities in a working context so that job demands can be taken into account and the most appropriate type of glove be chosen for each task. This study gives recommendations regarding the evaluation and use of gloves for screw-driving tasks.

  20. Penetration of protective gloves as a route of intake for tritiated water and 125I-labelled sodium iodine solution

    International Nuclear Information System (INIS)

    Harris, S.J.; Gilmore, A.

    1980-01-01

    Measurements have been made of the rate at which tritiated water and 125 I-labelled sodium iodide solution penetrate various types of protective gloves, both isotopes being in common use in this form in universities and similar establishments. Diffusion coefficients relating to the glove materials are also determined. The health physics aspects are discussed and it is concluded that intakes by workers through intact gloves are not likely to be of major significance and can easily be minimised by the correct use and choice of glove. (author)

  1. Rubber gloves biodegradation by a consortium, mixed culture and pure culture isolated from soil samples.

    Science.gov (United States)

    Nawong, Chairat; Umsakul, Kamontam; Sermwittayawong, Natthawan

    2018-02-03

    An increasing production of natural rubber (NR) products has led to major challenges in waste management. In this study, the degradation of rubber latex gloves in a mineral salt medium (MSM) using a bacterial consortium, a mixed culture of the selected bacteria and a pure culture were studied. The highest 18% weight loss of the rubber gloves were detected after incubated with the mixed culture. The increased viable cell counts over incubation time indicated that cells used rubber gloves as sole carbon source leading to the degradation of the polymer. The growth behavior of NR-degrading bacteria on the latex gloves surface was investigated using the scanning electron microscope (SEM). The occurrence of the aldehyde groups in the degradation products was observed by Fourier Transform Infrared Spectroscopy analysis. Rhodococcus pyridinivorans strain F5 gave the highest weight loss of rubber gloves among the isolated strain and posses latex clearing protein encoded by lcp gene. The mixed culture of the selected strains showed the potential in degrading rubber within 30 days and is considered to be used efficiently for rubber product degradation. This is the first report to demonstrate a strong ability to degrade rubber by Rhodococcus pyridinivorans. Copyright © 2018. Published by Elsevier Editora Ltda.

  2. An Evaluation of the Effect of Various Gloves on Polymerization Inhibition of Elastomeric Impression Materials: An In vitro Study.

    Science.gov (United States)

    Hiremath, Vinuta; Vinayakumar, G; Ragher, Mallikarjuna; Rayannavar, Sounyala; Bembalagi, Mahantesh; Ashwini, B L

    2017-11-01

    Latex protective barriers such as gloves and rubber dam material have been used widely in restorative procedures for crown and bridge. However, the chemical used during latex glove fabrication is thought to inhibit the polymerization of elastomeric impression materials used for impression making which has a detrimental effect on the dimensional accuracy and surface definition of resultant casts used for restorative procedures. The objectives of the study were to examine the surface of different elastomeric impressions on contact with various gloves. This clinical study included a total of eighty specimens of two types of the putty elastomeric impression material were hand manipulated by wearing three different gloves materials and is placed on a marked area of a clean and alcohol-treated glass slab at room temperature. The specimens examined for any signs of polymerization inhibition. The specimen will be rated as being "inhibited" if any residue remains on the glass slab and absence of the above will result as "no inhibition." The results showed no interference with the polymerization inhibition of the selected elastomers followed by the nitrile glove. The latex gloves showed inhibited set of the elastomeric impression material but set after sometime confirming time-dependent inhibition of the impression material. This study shows that the use of latex and sometime nitrile gloves during crown and bridge procedures should be contraindicated and the use of vinyl gloves should be stressed when working with elastomeric impression materials.

  3. Decontamination of latex gloves; Decontamination de gants en latex

    Energy Technology Data Exchange (ETDEWEB)

    Boutot, P; Schipfer, P; Blachere, A [Commissariat a l' Energie Atomique, Chusclan (France). Centre de Production de Plutonium de Marcoule

    1969-07-01

    Initially the latex gloves used in controlled zones were processed after use as radioactive waste. In view of the continually increasing number used, however, the persons in charge of the SPRAR have considered the possibility of decontaminating the gloves and using them again after control. The recovery installations which have been developed were initially designed rather crudely and operated irregularly; they have been progressively improved as a result of the experience acquired; today they are more really an industrial concern, equipped with automatic machinery. In 1967 it has been possible with this set-up to recover 247000 pairs of gloves, representing nearly 70 per cent of the number treated. (author) [French] Initialement, les gants de latex utilises dans les zones controlees etaient conditionnes apres emploi comme dechets radioactifs. Mais, devant l'augmentation sans cesse croissante des quantites employees, les responsables du SPRAR ont envisage leur decontamination et leur recyclage apres controles. Les installations de recuperation mises au point, de conception artisanale et fonctionnant de maniere episodique au depart, se sont progressivement ameliorees au fur et a mesure de l'experience acquise; elles revetent aujourd'hui le caractere d'une exploitation industrielle equipee de machines automatiques. En 1967, ces nouvelles installations ont permis de recuperer 247000 paires de gants, ce qui represente pres de 70 pour cent des quantites traitees. (auteur)

  4. IMMEDIATE AND DELAYED HYPERSENSITIVITY REACTIONS TO LATEX GLOVES IN A DENTAL STUDENT. A case report.

    Directory of Open Access Journals (Sweden)

    Iliyana Stoeva

    2011-08-01

    Full Text Available The article presents a case of dental student with immediate and delayed hypersensitivity reaction to latex gloves. Symptoms appeared during the second year of regularly using of latex gloves. The student was with no history of allergies and no previous exposure to latex products.

  5. Glove box operations for transplutonium element production

    International Nuclear Information System (INIS)

    Knauer, J.B.; Alexander, C.W.; Wiggins, J.T.

    1986-01-01

    Glove boxes are used in the Transuranium Processing Plant (TRU) at Oak Ridge National Laboratory for (1) completing the final chemical processing steps to isolate and purify the transplutonium elements, (2) packaging transplutonium elements for shipment, (3) preirradiation and postirradiation processing of samples used to produce special transplutonium isotopes in the High Flux Isotope Reactor (HFIR), and (4) conducting special projects, which include providing highly purified transplutonium products in special chemical forms and/or in experimental devices as requested by researchers. During 20 years of operation, the quantities of transplutonium elements produced, and thus the amount of radioactivity handled, have continually increased. At the same time, substantial effort has been expended to reduce personnel radiation exposures. Equipment and techniques have been developed to maintain the desired operational capabilities in the glove boxes while keeping radiation exposures to operating personnel as low as reasonably achievable. Developments have included the design and fabrication of product handling and collection devices, product storage containers, and laminated exterior shields of lead glass, lead acrylic, acrylic sheets, polyethylene, and lead

  6. Permeability of gloves used in nuclear medicine departments to [(99m)Tc]-pertechnetate and [(18)F]-fluorodeoxyglucose: radiation protection considerations.

    Science.gov (United States)

    Ridone, S; Matheoud, R; Valzano, S; Di Martino, R; Vigna, L; Brambilla, M

    2013-09-01

    In order to evaluate the safety of the individual protection devices, the permeability of four different types of disposable gloves, commonly used in hospitals, was tested in relation to [(99m)Tc]-pertechnetate and to [(18)F]-fluorodeoxyglucose ([(18)F]-FDG). From these radiopharmaceutical solutions, a drop was deposited on the external surface of the glove which was opened and stretched with the external surface placed upward. The smear test technique permitted to evaluate the activity onto the inner surface of the glove at different times. The smear tests were measured in a well sodium iodide detector calibrated in efficiency for (99m)Tc and (18)F. The permeability was tested on ten samples of each type of gloves and was expressed as the ratio of the activity onto the inner surface at each time interval to the activity deposited on the external surface of the glove. For each type of gloves and for each sampling time, mean value, standard deviation and percentage coefficient of variation of permeability were evaluated. One type of gloves showed a low resistance to permeation of both radiopharmaceuticals, while another one only to pertechnetate. The other gloves were good performers. The results of this study suggest to test permeability for gloves used for handling radiopharmaceuticals, before their adoption in the clinical routine. This practice will provide a more careful service of radiation protection for nuclear medicine department staff. Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  7. Single-incision laparoscopic appendectomy using homemade glove port at low cost

    Directory of Open Access Journals (Sweden)

    Sang Myoung Lee

    2016-01-01

    Full Text Available Purpose: The aim of this study was to report homemade glove port technique for single-incision laparoscopic appendectomy (SILA. Materials and Methods: Our homemade glove port was composed of a size 6 latex sterile surgical glove, a sterilized plastic bangle, and three pieces of silicon tube (5 cm in length that were used as the suction tube. Clinical data were retrospectively collected from those patients who underwent SILA at Bucheon St. Mary's Hospital, Bucheon, Gyeonggi-do, South Korea between February 2014 and June 2014, including patient demographics, and operative and postoperative outcomes. To compare the outcomes, a retrospective review was performed for those patients who underwent conventional laparoscopic appendectomy (CLA between October 2013 and January 2014. Both SILA and CLA were performed by the same surgical team. Results: The SILA and CLA groups included 37 and 57 patients, respectively. The mean age, weight, body mass index (BMI, operation time, and pathologic diagnosis of gangrenous appendicitis were not significantly different between the two groups. However, the mean hospital stay in the CLA group was significantly (P = 0.018 longer than that in the SILA group (4.2 days vs 3.5 days. There was no conversion to open surgery in both the groups. Of the cases who underwent SILA, 10 (27.0% needed insertion of additional port and drain. There was one (3.2% complication of umbilical surgical site infection. Conclusion: In this study, SILA, with homemade glove port, was technically feasible and safe at low cost.

  8. F-16XL Ship #2 Laminar Flow Glove mounting

    Science.gov (United States)

    1995-01-01

    NASA's two-seat F-16XL research aircraft is shown in the modification hangar at NASA's Dryden Flight Research Center, Edwards, California, during installation of a titanium 'glove' on the upper surface of its modified left wing. The aircraft subsequently carried out a 13-month-long, 45-flight research program which investigated drawing off a small part of the boundary-layer air in order to provide laminar--or smooth--flow over a major portion of a wing flying at supersonic speeds. A turbo-compressor in the aircraft's fuselage provided suction to draw air through more than 10 million tiny laser-drilled holes in the glove via a manifold system employing 20 valves. Data obtained during the program could assist designers of future aircraft in developing a more efficient high-speed civil transport.

  9. Specific risk factors and macroeconomic factor on profitability performance an empirical evidence of Top Glove Corporation Bhd

    OpenAIRE

    Loh, Choon Zhee

    2017-01-01

    The purpose of this study to conducted the overall performance of Top Glove Corporation with specific risk factors and macroeconomic factor on profitability performance. The data acquired from annual report of Top Glove Corporation starting from the year of 2011 until 2015. The measurement of liquidity ratio and operating ratio used to see the overall performance of Top Glove in 5 years which allegedly beyond benchmark. The additional measurement is the asset size, this variable has a negativ...

  10. Monitoring Human Performance During Suited Operations: A Technology Feasibility Study Using EMU Gloves

    Science.gov (United States)

    Bekdash, Omar; Norcross, Jason; McFarland, Shane

    2015-01-01

    Mobility tracking of human subjects while conducting suited operations still remains focused on the external movement of the suit and little is known about the human movement within it. For this study, accelerometers and bend sensitive resistors were integrated into a custom carrier glove to quantify range of motion and dexterity from within the pressurized glove environment as a first stage feasibility study of sensor hardware, integration, and reporting capabilities. Sensors were also placed on the exterior of the pressurized glove to determine if it was possible to compare a glove joint angle to the anatomical joint angle of the subject during tasks. Quantifying human movement within the suit was feasible, with accelerometers clearly detecting movements in the wrist and reporting expected joint angles at maximum flexion or extension postures with repeatability of plus or minus 5 degrees between trials. Bend sensors placed on the proximal interphalangeal and distal interphalangeal joints performed less well. It was not possible to accurately determine the actual joint angle using these bend sensors, but these sensors could be used to determine when the joint was flexed to its maximum and provide a general range of mobility needed to complete a task. Further work includes additional testing with accelerometers and the possible inclusion of hardware such as magnetometers or gyroscopes to more precisely locate the joint in 3D space. We hope to eventually expand beyond the hand and glove and develop a more comprehensive suit sensor suite to characterize motion across more joints (knee, elbow, shoulder, etc.) and fully monitor the human body operating within the suit environment.

  11. An Instrumented Glove for Control Audiovisual Elements in Performing Arts

    Directory of Open Access Journals (Sweden)

    Rafael Tavares

    2018-02-01

    Full Text Available The use of cutting-edge technologies such as wearable devices to control reactive audiovisual systems are rarely applied in more conventional stage performances, such as opera performances. This work reports a cross-disciplinary approach for the research and development of the WMTSensorGlove, a data-glove used in an opera performance to control audiovisual elements on stage through gestural movements. A system architecture of the interaction between the wireless wearable device and the different audiovisual systems is presented, taking advantage of the Open Sound Control (OSC protocol. The developed wearable system was used as audiovisual controller in “As sete mulheres de Jeremias Epicentro”, a portuguese opera by Quarteto Contratempus, which was premiered in September 2017.

  12. An evaluation of the effect of various gloves on polymerization inhibition of elastomeric impression materials: An In vitro study

    Directory of Open Access Journals (Sweden)

    Vinuta Hiremath

    2017-01-01

    Full Text Available Background: Latex protective barriers such as gloves and rubber dam material have been used widely in restorative procedures for crown and bridge. However, the chemical used during latex glove fabrication is thought to inhibit the polymerization of elastomeric impression materials used for impression making which has a detrimental effect on the dimensional accuracy and surface definition of resultant casts used for restorative procedures. The objectives of the study were to examine the surface of different elastomeric impressions on contact with various gloves. Materials and Methods: This clinical study included a total of eighty specimens of two types of the putty elastomeric impression material were hand manipulated by wearing three different gloves materials and is placed on a marked area of a clean and alcohol-treated glass slab at room temperature. The specimens examined for any signs of polymerization inhibition. The specimen will be rated as being “inhibited” if any residue remains on the glass slab and absence of the above will result as “no inhibition.” Results: The results showed no interference with the polymerization inhibition of the selected elastomers followed by the nitrile glove. The latex gloves showed inhibited set of the elastomeric impression material but set after sometime confirming time-dependent inhibition of the impression material. Conclusion: This study shows that the use of latex and sometime nitrile gloves during crown and bridge procedures should be contraindicated and the use of vinyl gloves should be stressed when working with elastomeric impression materials.

  13. Is hand hygiene before putting on nonsterile gloves in the intensive care unit a waste of health care worker time?--a randomized controlled trial.

    Science.gov (United States)

    Rock, Clare; Harris, Anthony D; Reich, Nicholas G; Johnson, J Kristie; Thom, Kerri A

    2013-11-01

    Hand hygiene (HH) is recognized as a basic effective measure in prevention of nosocomial infections. However, the importance of HH before donning nonsterile gloves is unknown, and few published studies address this issue. Despite the lack of evidence, the World Health Organization and other leading bodies recommend this practice. The aim of this study was to assess the utility of HH before donning nonsterile gloves prior to patient contact. A prospective, randomized, controlled trial of health care workers entering Contact Isolation rooms in intensive care units was performed. Baseline finger and palm prints were made from dominant hands onto agar plates. Health care workers were then randomized to directly don nonsterile gloves or perform HH and then don nonsterile gloves. Postgloving finger and palm prints were then made from the gloved hands. Plates were incubated and colony-forming units (CFU) of bacteria were counted. Total bacterial colony counts of gloved hands did not differ between the 2 groups (6.9 vs 8.1 CFU, respectively, P = .52). Staphylococcus aureus was identified from gloves (once in "hand hygiene prior to gloving" group, twice in "direct gloving" group). All other organisms were expected commensal flora. HH before donning nonsterile gloves does not decrease already low bacterial counts on gloves. The utility of HH before donning nonsterile gloves may be unnecessary. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  14. The fastest field sport in the world: A case report on 3-dimensional printed hurling gloves to help prevent injury.

    Science.gov (United States)

    Harte, Daniel; Paterson, Abby

    2017-10-28

    Case series. Hand injuries are the most common injury observed in hurling although compliance in wearing protective gloves is reportedly low. To devise a glove that offers comfort, protection and freedom of movement, using the bespoke capabilities of 3-dimensional (3D) printing. Each player's "catching" hand was imaged using a 3D scanner to produce a bespoke glove that they later trialed and provided feedback. Nine players provided feedback. On average, the players favorably rated the glove for the protection offered. The average response on comfort was poor, and no players reported that glove aided performance during play. This feasibility study explores the versatility of 3D printing as a potential avenue to improve player compliance in wearing protective sportswear. Feedback will help refine glove design for future prototypes. Hurling is the primary focus in this study, but knowledge gains should be transferable to other sports that have a high incidence of hand injury. 4. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  15. Isolation and identification of some unknown substances in disposable nitrile-butadiene rubber gloves used for food handling.

    Science.gov (United States)

    Mutsuga, M; Wakui, C; Kawamura, Y; Maitani, T

    2002-11-01

    In Japan, disposable gloves made from nitrile-butadiene rubber (NBR) are frequently used in contact with foods. In a previous paper, we investigated substances migrating from various gloves made of polyvinyl chloride, polyethylene, natural rubber and NBR. Zinc di-n-butyldithiocarbamate (ZDBC), diethyldithiocarbamate (ZDEC) used as vulcanization accelerators, di(2-ethylhexyl)phthalate (DEHP) used as a plasticizer and many unknown compounds that migrated from NBR gloves into n-heptane were detected by GC/MS. In this paper, six unknown compounds were obtained from one kind of NBR glove by n-hexane extraction and each was isolated by silica gel chromatography. From the results of NMR and mass spectral analysis of the six unknown compounds, their structures are proposed as 1,4-dione-2,5-bis(1,1-dimethylpropyl)cyclohexadiene (1), 2-(1,1-dimethylethyl)-4-(1,1,3,3-tetra methylbutyl)phenol (2), 2,6-bis(1,1-dimethylethyl)-4-(1,1,3,3-tetramethylbutyl)phenol (3), 2,4-bis(1,1,3,3-tetramethylbutyl)phenol (4), 2-(1,1-dimethylethyl)4,6-bis(1,1,3,3-tetramethylbutyl)phenol (5) and 2,4,6-tris(1,1,3,3-tetramethylbutyl)phenol (6). Compound 1 was observed in five of the seven kinds of NBR gloves, and compounds 2-4 and 6, which are not listed in Chemical Abstract (CA), were present in four kinds of gloves.

  16. Gloves against mineral oils and mechanical hazards: composites of carboxylated acrylonitrile-butadiene rubber latex.

    Science.gov (United States)

    Krzemińska, Sylwia; Rzymski, Władysław M; Malesa, Monika; Borkowska, Urszula; Oleksy, Mariusz

    2016-09-01

    Resistance to permeation of noxious chemical substances should be accompanied by resistance to mechanical factors because the glove material may be torn, cut or punctured in the workplace. This study reports on glove materials, protecting against mineral oils and mechanical hazards, made of carboxylated acrylonitrile-butadiene rubber (XNBR) latex. The obtained materials were characterized by a very high resistance of the produced materials to oil permeation (breakthrough time > 480 min). The mechanical properties, and especially tear resistance, of the studied materials were improved after the addition of modified bentonite (nanofiller) to the XNBR latex mixture. The nanocomposite meets the requirements in terms of parameters characterizing tear, abrasion, cut and puncture resistance. Therefore, the developed material may be used for the production of multifunctional protective gloves.

  17. The Influence of Robotic Assistance on Reducing Neuromuscular Effort and Fatigue during Extravehicular Activity Glove Use

    Science.gov (United States)

    Madden, Kaci E.; Deshpande, Ashish D.; Peters, Benjamin J.; Rogers, Jonathan M.; Laske, Evan A.; McBryan, Emily R.

    2017-01-01

    The three-layered, pressurized space suit glove worn by Extravehicular Activity (EVA) crew members during missions commonly causes hand and forearm fatigue. The Spacesuit RoboGlove (SSRG), a Phase VI EVA space suit glove modified with robotic grasp-assist capabilities, has been developed to augment grip strength in order to improve endurance and reduce the risk of injury in astronauts. The overall goals of this study were to i) quantify the neuromuscular modulations that occur in response to wearing a conventional Phase VI space suit glove (SSG) during a fatiguing task, and ii) determine the efficacy of Spacesuit RoboGlove (SSRG) in reversing the adverse neuromuscular modulations and restoring altered muscular activity to barehanded levels. Six subjects performed a fatigue sequence consisting of repetitive dynamic-gripping interspersed with isometric grip-holds under three conditions: barehanded, wearing pressurized SSG, and wearing pressurized SSRG. Surface electromyography (sEMG) from six forearm muscles (flexor digitorum superficialis (FDS), flexor carpi radialis (FCR), flexor carpi ulnaris (FCU), extensor digitorum (ED), extensor carpi radialis longus (ECRL), and extensor carpi ulnaris (ECU)) and subjective fatigue ratings were collected during each condition. Trends in amplitude and spectral distributions of the sEMG signals were used to derive metrics quantifying neuromuscular effort and fatigue that were compared across the glove conditions. Results showed that by augmenting finger flexion, the SSRG successfully reduced the neuromuscular effort needed to close the fingers of the space suit glove in more than half of subjects during two types of tasks. However, the SSRG required more neuromuscular effort to extend the fingers compared to a conventional SSG in many subjects. Psychologically, the SSRG aided subjects in feeling less fatigued during short periods of intense work compared to the SSG. The results of this study reveal the promise of the SSRG as a

  18. Selecting protective gloves for oil spill response and cleanup

    International Nuclear Information System (INIS)

    McDermott, H.J.

    1993-01-01

    Oil spill responders and cleanup workers must be provided with gloves that prevent skin contact while permitting them to do their job safely and efficiently. Glove selection is largely based on professional judgment, considering permeation, resistance to puncture and abrasion, and whether the material gets slick when coated with oil. This paper consolidates the most useful information from various studies and presents a selection rationale. In general, we found neoprene, polyvinyl chloride (PVC), and nitrile to be the glove materials of choice for protection in oil spills. The skin toxicity potential for most petroleum materials encountered in a spill is low. Some fresh crudes may contain hydrocarbon molecules that may penetrate the skin and cause some systemic toxicity with high enough exposure. However, as crude weathers, the more volatile hydrocarbons evaporate rapidly, leaving behind the heavier fraction, which often contains polynuclear aromatic (PNA) compounds. Some PNAs have caused skin cancer in animals after prolonged and repeated contact. As a reference, most weathered crude is similar to used motor oil in skin toxicity; prolonged and repeated skin contact should be avoided, but there is no cause for concern if some gets on the skin. The typical skin problems from excessive skin contact are drying and cracking from the defatting action of the oil itself or from the soap or hand cleaners used to remove the oil, and pustules (similar to boils) if the oil plugs the sweat glands in the skin

  19. The Astronaut Glove Challenge: Big Innovation from a (Very) Small Team

    Science.gov (United States)

    Homer, Peter

    2008-01-01

    Many measurements were taken by test engineers from Hamilton Sundstrand, the prime contractor for the current EVA suit. Because the raw measurements needed to be converted to torques and combined into a final score, it was impossible to keep track of who was ahead in this phase. The final comfort and dexterity test was performed in a depressurized glove box to simulate real on-orbit conditions. Each competitor was required to exercise the glove through a defined set of finger, thumb, and wrist motions without any sign of abrasion or bruising of the competitor's hand. I learned a lot about arm fatigue! This was a pass-fail event, and both of the remaining competitors came through intact. After taking what seemed like an eternity to tally the final scores, the judges announced that I had won the competition. My glove was the only one to have achieved lower finger-bending torques than the Phase VI glove. Looking back, I see three sources of the success of this project that I believe also operate in other programs where small teams have broken new ground in aerospace technologies. These are awareness, failure, and trust. By remaining aware of the big picture, continuously asking myself, "Am I converging on a solution?" and "Am I converging fast enough?" I was able to see that my original design was not going to succeed, leading to the decision to start over. I was also aware that, had I lingered over this choice or taken time to analyze it, I would not have been ready on the first day of competition. Failure forced me to look outside conventional thinking and opened the door to innovation. Choosing to make incremental failures enabled me to rapidly climb the learning curve. Trusting my "gut" feelings-which are really an internalized accumulation of experiences-and my newly acquired skills allowed me to devise new technologies rapidly and complete both gloves just in time. Awareness, failure, and trust are intertwined: failure provides experiences that inform awareness

  20. Application of glove box robotics to hazardous waste management

    International Nuclear Information System (INIS)

    Dennison, D.K.; Hurd, R.L.; Merrill, R.D.; Reitz, T.C.

    1995-02-01

    Lawrence Livermore Laboratory (LLNL) is developing a semi-automated system for handling, characterizing, processing, sorting, and repackaging hazardous wastes containing tritium. The system combines an IBM developed gantry robot with a special glove box enclosure designed to protect the operators and minimize the potential release of tritium to the atmosphere. All hazardous waste handling and processing will be performed remotely using the robot in a telerobotic mode for one-of-a-kind functions and in an autonomous mode for repetitive type operations. The system will initially be used in conjunction with a portable gas system designed to capture any gaseous phase tritium released into the glove box. This paper presents the objectives of this program, provides background related to LLNL's robotics and waste handling program, describes the major system components, outlines system operation, and discusses current status and plans

  1. Mass spectrometric analysis of EPO IEF-PAGE interfering substances in nitrile examination gloves.

    Science.gov (United States)

    Reichel, Christian

    2012-10-01

    Direct detection of doping with recombinant erythropoietins (rhEPO) is accomplished by isoelectric focusing (IEF) or sodium dodecylsulfate (SDS) polyacrylamide gel electrophoresis (PAGE). In a recent publication, Lasne et al. (Electrophoresis 2011, 32, 1444) showed that improper use of nitrile examination gloves during sample collection, sample preparation, and IEF-PAGE may lead to distorted or absent EPO IEF-profiles. In order to clarify which substances are responsible for this observation, a mass spectrometric study on water extractable compounds found in nitrile gloves was performed. Several substance classes were shown to be present, among them polyethylene glycols (PEG), anionic and nonionic surfactants, as well as alcohol ethoxylates and plasticizers. It could be demonstrated that alkylbenzenesulfonates, the main category of detectable anionic detergents, and among them sodium dodecylbenzenesulfonate (SDBS) and its homologs, are the prime reason for the interference of nitrile gloves with EPO IEF-PAGE. Copyright © 2012 John Wiley & Sons, Ltd.

  2. Occlusive gloves and skin conditions: is there a problem? Results of a cross-sectional study in a semiconductor company.

    Science.gov (United States)

    Weistenhöfer, W; Wacker, M; Bernet, F; Uter, W; Drexler, H

    2015-04-01

    Although there is poor scientific evidence that working with occlusive gloves is as damaging as wet work, prolonged glove occlusion is considered to be a risk factor for developing hand eczema similar to wet work. To assess the effects of wearing occlusive gloves during the whole working day, without exposure to any additional hazardous substances, on skin condition and skin barrier function. We investigated 323 employees of a semiconductor production company in Germany: 177 clean-room workers wearing occlusive gloves during the whole shift (exposed group) and 146 employees working in administration (control group). A standardized interview was performed, the skin condition of both hands was studied using the quantitative skin score HEROS, and transepidermal water loss (TEWL) and stratum corneum hydration were measured. There was no significant difference in skin condition between the two subgroups. Values for TEWL and corneometry were significantly higher in exposed participants (P gloves at least 30 min before the measurement. Hence, the effect of occlusion on skin barrier function seems to be transient. Prolonged wearing of occlusive gloves with clean hands and without exposure to additional hazardous substances does not seem to affect the skin negatively. © 2014 British Association of Dermatologists.

  3. Gloves against mineral oils and mechanical hazards: composites of carboxylated acrylonitrile–butadiene rubber latex

    Science.gov (United States)

    Krzemińska, Sylwia; Rzymski, Władysław M.; Malesa, Monika; Borkowska, Urszula; Oleksy, Mariusz

    2016-01-01

    Resistance to permeation of noxious chemical substances should be accompanied by resistance to mechanical factors because the glove material may be torn, cut or punctured in the workplace. This study reports on glove materials, protecting against mineral oils and mechanical hazards, made of carboxylated acrylonitrile–butadiene rubber (XNBR) latex. The obtained materials were characterized by a very high resistance of the produced materials to oil permeation (breakthrough time > 480 min). The mechanical properties, and especially tear resistance, of the studied materials were improved after the addition of modified bentonite (nanofiller) to the XNBR latex mixture. The nanocomposite meets the requirements in terms of parameters characterizing tear, abrasion, cut and puncture resistance. Therefore, the developed material may be used for the production of multifunctional protective gloves. PMID:26757889

  4. Protection during production: Problems due to prevention? Nail and skin condition after prolonged wearing of occlusive gloves.

    Science.gov (United States)

    Weistenhöfer, Wobbeke; Uter, Wolfgang; Drexler, Hans

    2017-01-01

    Wearing of occlusive gloves during the whole working shift is considered a risk factor for developing hand eczema, similar to wet work. Moreover, the increased hydration due to glove occlusion may lead to brittle nails. Two hundred and seventy clean room workers, wearing occlusive gloves for prolonged periods, and 135 administrative employees not using gloves were investigated. This included a dermatological examination of the nails and the hands, using the Hand Eczema ScoRe for Occupational Screening (HEROS), measurement of transepidermal water loss (TEWL), and a standardized interview. Of the clean room workers, 39%, mainly women, reported nail problems, mostly brittle nails with onychoschisis. Skin score values showed no significant differences between HEROS values of both groups. TEWL values of exposed subjects were similar to TEWL values of controls 40 min after taking off the occlusive gloves. In a multiple linear regression analysis, male gender and duration of employment in the clean room were associated with a significant increase in TEWL values. The effect of occlusion on TEWL seems to be predominantly transient and not be indicative of a damaged skin barrier. This study confirmed the results of a previous investigation showing no serious adverse effect of wearing of occlusive gloves on skin condition without exposure to additional hazardous substances. However, occlusion leads to softened nails prone to mechanical injury. Therefore, specific prevention instructions are required to pay attention to this side effect of occlusion.

  5. Utilizing Glove-Based Gestures and a Tactile Vest Display for Covert Communications and Robot Control

    Science.gov (United States)

    2014-06-01

    wearing instrumented glove for hand and arm signals. .......................................9 Figure 4. TDS Nomad handheld computer...of a standard tactical glove with accelerometers embedded within each finger, and an accelerometer, gyroscope, and digital compass embedded in the...signal communication were performed by two TDS Nomad GPS-enabled ruggedized handheld computers (one carried by the individual generating hand signals and

  6. Penelitian jumlah penggunaan bating agent pada penyamakan kulit sarung tangan (fashion glove dari kulit kelinci

    Directory of Open Access Journals (Sweden)

    Muchtar Lutfi

    1994-04-01

    Full Text Available The objective of this research is to identify the quatity of bating agent used in tanning rabbit skins to be glove leather, to make use rabbit skins which can not be tanned to fur rabbit skin leather. The materials used in this research were of 40 pieces of lokal salt preservated rabbit skins originated from Yogyakarta having quality III and IV. They were grouped into four and the groups consisted of ten pieces each were tanned to be fashion glove leather using 4% formaline as pretanning agent and followed by chrome tanning agent as the retanning agent. Before carrying out both tanning processes bating was done on them using Pancreol Bate as bating agent. The quantity of bating agent added was varried as 0,65%, 1,2%, 1,8% and 2,4%. The process used was of usually carried - out by IRDLAI. The leather produced were tested on their sotfness, with sheepskin glove leather was used as the measuring- rod; their tensile strength resistance and flexibility with SII. 0061 – 74 (Quality and test method for goatsheep skin glove and garment leather as the standard of comparison. The test results were statistically evaluated. A conclusion can be down from this research that by using 0,6% Pancreol Bate on bating process, soft glove leathers having good tensile strength and flexibility which fulfill the requirements of SII. 0061 - 74 can be produced.

  7. Hand hygiene with alcohol hand rub and gloves reduces the incidence of late onset sepsis in preterm neonates.

    Science.gov (United States)

    Janota, Jan; Šebková, Sylva; Višňovská, Magda; Kudláčková, Jana; Hamplová, Drahomíra; Zach, Jiří

    2014-10-01

    To assess the impact of a hand hygiene protocol, using hand washing, alcohol hand rub and gloves when caring for preterm infants born after 31 weeks of gestation, on the incidence of neonatal late onset sepsis (LOS). All babies delivered between 32 + 0 and 36 + 6 weeks gestation and admitted to the neonatal intensive care unit during a 14-month period were included. We followed a hand hygiene protocol with hand washing and alcohol hand rub (hand rub period) for the first 7 months and a protocol of hand washing, alcohol hand rub and gloves (gloves period) for the second 7 months. The hand rub and gloves groups consisted of 111 and 89 patients, respectively. Five patients were diagnosed with a total of six episodes of LOS in the hand rub group, and the incidence of LOS during the hand rub period was 2.99/1000 hospital days and 54.1/1000 admissions. There were no patients diagnosed with LOS during the gloves period (significant decrease, p = 0.028). Using a hand hygiene protocol with hand washing, hand rub and gloves significantly reduced the incidence of LOS in preterm newborns, and the results suggest that it may produce a sustained improvement in the infection rate. ©2014 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  8. COMPUTER MODEL AND SIMULATION OF A GLOVE BOX PROCESS

    International Nuclear Information System (INIS)

    Foster, C.

    2001-01-01

    The development of facilities to deal with the disposition of nuclear materials at an acceptable level of Occupational Radiation Exposure (ORE) is a significant issue facing the nuclear community. One solution is to minimize the worker's exposure though the use of automated systems. However, the adoption of automated systems for these tasks is hampered by the challenging requirements that these systems must meet in order to be cost effective solutions in the hazardous nuclear materials processing environment. Retrofitting current glove box technologies with automation systems represents potential near-term technology that can be applied to reduce worker ORE associated with work in nuclear materials processing facilities. Successful deployment of automation systems for these applications requires the development of testing and deployment strategies to ensure the highest level of safety and effectiveness. Historically, safety tests are conducted with glove box mock-ups around the finished design. This late detection of problems leads to expensive redesigns and costly deployment delays. With wide spread availability of computers and cost effective simulation software it is possible to discover and fix problems early in the design stages. Computer simulators can easily create a complete model of the system allowing a safe medium for testing potential failures and design shortcomings. The majority of design specification is now done on computer and moving that information to a model is relatively straightforward. With a complete model and results from a Failure Mode Effect Analysis (FMEA), redesigns can be worked early. Additional issues such as user accessibility, component replacement, and alignment problems can be tackled early in the virtual environment provided by computer simulation. In this case, a commercial simulation package is used to simulate a lathe process operation at the Los Alamos National Laboratory (LANL). The Lathe process operation is indicative of

  9. ALTERATIONS IN ELECTROCARDIOGRAMS OF LABRADOR RETRIEVER DOGS DURING HANDLING WITH AND WITHOUT GLOVES

    Directory of Open Access Journals (Sweden)

    Swagat Mohapatra

    2016-12-01

    Full Text Available Healthy male Labrador Retriever dogs (n=8 aged between one to three years constituted the study material. The study was carried out to peruse the alterations in electrocardiograms, when the attendant restrained the dogs with bare hands and when the dogs were restrained by the attendant wearing gloves. The mean amplitude of P wave was higher in dogs handled with gloves. Similarly, the amplitudes of QRS complex and T wave were higher in the electrocardiograms of dogs handled with insulated hands. Meanwhile, the duration of T wave and Q-T interval were higher in the electrocardiograms recorded without gloves in hands. However, no alterations were perceived with respect to the duration of P wave, duration of T wave, the P-R interval, R-R interval and the heart rate. Except for the amplitude of P wave, no other differences were statistically significant. The study reported the alterations in the electrocardiogram while handling the animals with bare hands.

  10. Using the skin protective lotion IB1 as a substitute for chemical protective gloves.

    Science.gov (United States)

    Ophir, Nimrod; Milk, Nadav; Mayer, Talia; Ravfogel, Shaul; Yavnai, Nirit; Eisenkraft, Arik; Kadar, Tamar; Kassirer, Michael; Rosman, Yossi

    2016-10-01

    We aimed to evaluate the performance of medical personnel in using the IB1 topical protective lotion on their hands and wrists together with standard disposable medical gloves, compared to standard-issued medical chemical protective gloves. This randomized cross-over study included 144 medical personnel. Primary endpoints were time-to-completion of autoinjection; success rate, number of attempts, and time-to-achieve successful endotracheal intubation; time-to-achieve satisfactory tube fixation; time-to-draw and inject the content of an ampoule; and the total time-to-perform all medical procedures. Secondary endpoints included the subjective assessment of convenience to perform these four procedures with each protective measure. Mean time was significantly shorter using IB1 compared to chemical protective gloves for tube fixation, ampoule drawing, and the total time-to-perform all procedures (58.6±22.7 seconds vs. 71.7±29.7; 31.5±21.8 vs. 38.2±19.4; 137.4±56.1 vs. 162.5±63.6, respectively; Pgloves (Pgloves significantly shorten the time-to-perform medical procedures requiring fine motor dexterities and is subjectively more convenient than chemical protective gloves. IB1 should be considered as an appropriate alternative for medical teams in a chemical event. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. A quantification of occupational skin exposures and the use of protective gloves among hairdressers in Denmark.

    Science.gov (United States)

    Lysdal, Susan Hovmand; Johansen, Jeanne Duus; Flyvholm, Mari-Ann; Søsted, Heidi

    2012-06-01

    Occupational hand eczema is common in hairdressers, owing to excessive exposure to wet work and hairdressing chemicals. To quantify occupational skin exposure and the use of protective gloves among hairdressers in Denmark. A register-based study was conducted comprising all graduates from hairdressing vocational schools from 1985 to 2007 (n = 7840). The participants received a self-administered postal questionnaire in May 2009, including questions on hairdressing tasks performed in the past week at work and the extent of glove use. A response rate of 67.9% (n = 5324) was obtained. Of the respondents, 55.7% still worked as hairdressers, and they formed the basis of this study. Daily wet work was excessive; 86.6% had wet hands for ≥2 hr, and 54% for ≥ 4 hr. Glove use was fairly frequent for full head hair colouring and bleaching procedures (93-97.7%), but less frequent for highlighting/lowlighting procedures (49.7-60.5%) and permanent waving (28.3%). Gloves were rarely worn during hair washing (10%), although this was more frequently the case after hair colouring procedures (48.9%). Occupational skin exposure was excessive among hairdressers; the extent of wet work and chemical treatments was high, and glove use was inconsistent, especially for certain hair colouring procedures and wet work tasks. © 2012 John Wiley & Sons A/S.

  12. Adaptation of a glow discharge mass spectrometer in a glove-box for the analysis of nuclear materials

    International Nuclear Information System (INIS)

    Betti, M.; Rasmussen, G.; Hiernaut, T.; Koch, L.

    1994-01-01

    A VG9000 glow discharge mass spectrometer has been modified for the direct analysis of solid nuclear samples within a glove-box environment. Because containment is needed for the analysis of this kind of material, the glove-box encloses all parts of the instrument that come into contact with the sample, namely the ion source chamber, sample interlock and associated pumping system. External modifications eliminate outside contamination by the fitting of absolute filters on all source supplies. Internally the design of the ion source has been altered to minimize the number of operations performed inside the glove-box thereby simplifying operation and routine maintenance. These modifications retain the ion extraction and focusing properties of the instrument. The data presented show that there is no compromise in the analytical performance of the instrument when placed in the glove-box. Data representative of nuclear materials is also shown. (Author)

  13. Chemical Resistance of Disposable Nitrile Gloves Exposed to Simulated Movement

    Science.gov (United States)

    Phalen, Robert N.; Wong, Weng Kee

    2012-01-01

    Large discrepancies between laboratory permeation testing and field exposures have been reported, with indications that hand movement could account for a portion of these differences. This study evaluated the influence of simulated movement on chemical permeation of 30 different disposable nitrile glove products. Products were investigated out-of-box and with exposure to simulated whole-glove movement. Permeation testing was conducted using ethanol as a surrogate test chemical. A previously designed pneumatic system was used to simulate hand movement. No movement and movement tests were matched-paired to control for environmental conditions, as were statistical analyses. Permeation data were collected for a 30-min exposure period or until a breakthrough time (BT) and steady-state permeation rate (SSPR) could be determined. A third parameter, area under the curve at 30 min (AUC-30), was used to estimate potential worker exposure. With movement, a significant decrease in BT (p ≤ 0.05), ranging from 6–33%, was observed for 28 products. The average decrease in BT was 18% (p ≤ 0.001). With movement, a significant increase in SSPR (p ≤ 0.05), ranging from 1–78%, was observed with 25 products. The average increase in SSPR was 18% (p ≤ 0.001). Significant increases in AUC-30 (p ≤ 0.05), ranging from 23–277%, were also observed for all products where it could be calculated. On average, there was a 58% increase (p ≤ 0.001). The overall effect of movement on permeation through disposable nitrile gloves was significant. Simulated movement significantly shortened the BT, increased the SSPR, and increased the cumulative 30-min exposure up to three times. Product variability also accounted for large differences, up to 40 times, in permeation and cumulative exposure. Glove selection must take these factors into account. It cannot be assumed that all products will perform in a similar manner. PMID:23009187

  14. Anthropomorphic Robot Hand And Teaching Glove

    Science.gov (United States)

    Engler, Charles D., Jr.

    1991-01-01

    Robotic forearm-and-hand assembly manipulates objects by performing wrist and hand motions with nearly human grasping ability and dexterity. Imitates hand motions of human operator who controls robot in real time by programming via exoskeletal "teaching glove". Telemanipulator systems based on this robotic-hand concept useful where humanlike dexterity required. Underwater, high-radiation, vacuum, hot, cold, toxic, or inhospitable environments potential application sites. Particularly suited to assisting astronauts on space station in safely executing unexpected tasks requiring greater dexterity than standard gripper.

  15. FDM 3D printed coffee glove embedded with flexible electronic

    KAUST Repository

    Bahri, Meznan

    2017-10-31

    With the advances in 3D printing technology, Flexible Electronics can now be exploited to form the so-called “Embedded Electronics”. This paper describes experiences learned from a research project which ran during summer 2016 at KAUST, in collaboration with the Electrical and Computer Engineering Department at Effat University, and aimed at creating a heating coffee glove product operating on double alkaline batteries using Kapton© as a flexible substrate for the circuit. The circuit and its batteries are encapsulated in a 3D printed glove, designed using SolidWorks©. The proposed methodology and techniques applied during this work could be further used in implementing other technologies, such as thermoelectric coolers head patches, smart garments, and flexible smartphones. Limitation and recommendation of the present methodology are also discussed.

  16. Usage of Safety Gloves in the Gold Mining Industry

    CSIR Research Space (South Africa)

    Scheepers, JCE

    1978-10-01

    Full Text Available The safety departments of 31 mines were visited, and the data obtained was used to determine to what extent safety gloves were being used in the gold mining industry. The frequency of occurrence of hand injuries amongst black workers of the gold...

  17. Glove box adaptation, installation and commissioning of an assembled modular type atomic absorption unit with GF atomizer

    International Nuclear Information System (INIS)

    Gupta, Santosh Kumar; Thulasidas, S.K.; Goyal, Neelam; Godbole, S.V.

    2013-09-01

    The report describes glove box adaptation of an in-house developed AAS unit with GF as atomization source for determination of trace metallic elements in Pu bearing samples. In order to replace the old Varian Techtron GF-AAS which was utilized for analysis of Pu bearing samples for the last thirty seven years, and as of late was giving too many practical problems, a new GF-AAS was designed and reassembled. The original compact flame AAS unit available with M/s. Thermo Fisher India Pvt. Ltd, Nashik, was converted into separated modular unit viz. Hollow Cathode Lamp unit, Atomizer unit and Monochromator - Detector - Readout unit. In addition, these modular units were modified with respect to their dimensions so as to enable their use with existing glove box facility developed earlier in 1980 for glove box incorporation. These units were separated from each other at their factory site so as to enable us to incorporate atomizer unit alone in the glove box. Glove box adapted GF-AAS is essential for Radiochemistry Division to provide analytical services to Chemical Quality Control of Pu bearing nuclear and related materials and also as an analytical support to the R and D activities of the Radiochemistry Division, BARC. (author)

  18. Type I allergy to natural rubber latex and type IV allergy to rubber chemicals in health care workers with glove-related skin symptoms.

    Science.gov (United States)

    Nettis, E; Assennato, G; Ferrannini, A; Tursi, A

    2002-03-01

    It has been established that there are type I and type IV allergens in latex gloves. The purpose of the study was to establish the prevalence of rubber glove-induced skin symptoms among health care workers in one Italian hospital. Health care workers (n = 1584) were evaluated using a written questionnaire and 295 respondents with glove-induced skin symptoms were tested. We performed: skin prick test with latex glove extract and commercial latex, and environmental and food allergens; glove use test; patch tests with a rubber additive series; and RASTs. Hospital employees who used or had used latex gloves at work were 1294. Three hundred and sixteen (24.4%) reported glove-induced symptoms, namely, cutaneous symptoms in all the cases and non-cutaneous symptoms in 105 subjects (8.1%). Twenty-seven of the 295 symptomatic employees tested (9.1%) were latex sensitive. Thirty-one patients (10.5%) exhibited positive patch test to rubber-related allergens. The most positive readings were obtained from the Thiuram mix and the Carba mix, with 12 and 9 positivities, respectively. The risk factors for latex skin sensitization were: a previous history of atopy and asthma; history of surgery; pre-existing hand dermatitis; work-related symptoms; and positive skin tests to common inhalant and certain foods (P skin complaints of latex gloves are related to skin irritation rather than to allergy. The immediate allergy to latex and the delayed allergy to rubber chemicals suggest that all the health care workers with glove-related dermatitis should undergo both skin prick test and glove use test to detect type I hypersensitivity to latex, and patch test to detect type IV hypersensitivity to rubber chemicals.

  19. Frequent Multidrug-Resistant Acinetobacter baumannii Contamination of Gloves, Gowns, and Hands of Healthcare Workers

    Science.gov (United States)

    Morgan, Daniel J.; Liang, Stephen Y.; Smith, Catherine L.; Johnson, J. Kristie; Harris, Anthony D.; Furuno, Jon P.; Thom, Kerri A.; Snyder, Graham M.; Day, Hannah R.; Perencevich, Eli N.

    2010-01-01

    BACKGROUND Multidrug-resistant (MDR) gram-negative bacilli are important nosocomial pathogens. OBJECTIVE To determine the incidence of transmission of MDR Acinetobacter baumannii and Pseudomonas aeruginosa from patients to healthcare workers (HCWs) during routine patient care. DESIGN Prospective cohort study. SETTING Medical and surgical intensive care units. METHODS We observed HCWs who entered the rooms of patients colonized with MDR A. baumannii or colonized with both MDR A. baumannii and MDR P. aeruginosa. We examined their hands before room entry, their disposable gloves and/or gowns upon completion of patient care, and their hands after removal of gloves and/or gowns and before hand hygiene. RESULTS Sixty-five interactions occurred with patients colonized with MDR A. baumannii and 134 with patients colonized with both MDR A. baumannii and MDR P. aeruginosa. Of 199 interactions between HCWs and patients colonized with MDR A. baumannii, 77 (38.7% [95% confidence interval {CI}, 31.9%–45.5%]) resulted in HCW contamination of gloves and/or gowns, and 9 (4.5% [95% CI, 1.6%–7.4%]) resulted in contamination of HCW hands after glove removal before hand hygiene. Of 134 interactions with patients colonized with MDR P. aeruginosa, 11 (8.2% [95% CI, 3.6%–12.9%]) resulted in HCW contamination of gloves and/or gowns, and 1 resulted in HCW contamination of hands. Independent risk factors for contamination with MDR A. baumannii were manipulation of wound dressing (adjusted odds ratio [aOR], 25.9 [95% CI, 3.1–208.8]), manipulation of artificial airway (aOR, 2.1 [95% CI, 1.1–4.0]), time in room longer than 5 minutes (aOR, 4.3 [95% CI, 2.0–9.1]), being a physician or nurse practitioner (aOR, 7.4 [95% CI, 1.6–35.2]), and being a nurse (aOR, 2.3 [95% CI, 1.1–4.8]). CONCLUSIONS Gowns, gloves, and unwashed hands of HCWs were frequently contaminated with MDR A. baumannii. MDR A. baumannii appears to be more easily transmitted than MDR P. aeruginosa and perhaps more

  20. Outbreaks where food workers have been implicated in the spread of foodborne disease. Part 8. Gloves as barriers to prevent contamination of food by workers.

    Science.gov (United States)

    Todd, Ewen C D; Michaels, Barry S; Greig, Judy D; Smith, Debra; Bartleson, Charles A

    2010-09-01

    The role played by food workers and other individuals in the contamination of food has been identified as an important contributing factor leading to foodborne outbreaks. To prevent direct bare hand contact with food and food surfaces, many jurisdictions have made glove use compulsory for food production and preparation. When properly used, gloves can substantially reduce opportunities for food contamination. However, gloves have limitations and may become a source of contamination if they are punctured or improperly used. Experiments conducted in clinical and dental settings have revealed pinhole leaks in gloves. Although such loss of glove integrity can lead to contamination of foods and surfaces, in the food industry improper use of gloves is more likely than leakage to lead to food contamination and outbreaks. Wearing jewelry (e.g., rings) and artificial nails is discouraged because these items can puncture gloves and allow accumulation of microbial populations under them. Occlusion of the skin during long-term glove use in food operations creates the warm, moist conditions necessary for microbial proliferation and can increase pathogen transfer onto foods through leaks or exposed skin or during glove removal. The most important issue is that glove use can create a false sense of security, resulting in more high-risk behaviors that can lead to cross-contamination when employees are not adequately trained.

  1. Injury Risk Assessment of Extravehicular Mobility Unit (EMU) Phase VI and Series 4000 Gloves During Extravehicular Activity (EVA) Hand Manipulation Tasks

    Science.gov (United States)

    Kilby, Melissa

    2015-01-01

    Functional Extravehicular Mobility Units (EMUs) with high precision gloves are essential for the success of Extravehicular Activity (EVA). Previous research done at NASA has shown that total strength capabilities and performance are reduced when wearing a pressurized EMU. The goal of this project was to characterize the human-space suit glove interaction and assess the risk of injury during common EVA hand manipulation tasks, including pushing, pinching and gripping objects. A custom third generation sensor garment was designed to incorporate a combination of sensors, including force sensitive resistors, strain gauge sensors, and shear force sensors. The combination of sensors was used to measure the forces acting on the finger nails, finger pads, finger tips, as well as the knuckle joints. In addition to measuring the forces, data was collected on the temperature, humidity, skin conductance, and blood perfusion of the hands. Testing compared both the Phase VI and Series 4000 glove against an ungloved condition. The ungloved test was performed wearing the sensor garment only. The project outcomes identified critical landmarks that experienced higher workloads and are more likely to suffer injuries. These critical landmarks varied as a function of space suit glove and task performed. The results showed that less forces were acting on the hands while wearing the Phase VI glove as compared to wearing the Series 4000 glove. Based on our findings, the engineering division can utilize these methods for optimizing the current space suit glove and designing next generation gloves to prevent injuries and optimize hand mobility and comfort.

  2. Design and Preliminary Feasibility Study of a Soft Robotic Glove for Hand Function Assistance in Stroke Survivors.

    Science.gov (United States)

    Yap, Hong Kai; Lim, Jeong Hoon; Nasrallah, Fatima; Yeow, Chen-Hua

    2017-01-01

    Various robotic exoskeletons have been proposed for hand function assistance during activities of daily living (ADL) of stroke survivors. However, traditional exoskeletons involve the use of complex rigid systems that impede the natural movement of joints, and thus reduce the wearability and cause discomfort to the user. The objective of this paper is to design and evaluate a soft robotic glove that is able to provide hand function assistance using fabric-reinforced soft pneumatic actuators. These actuators are made of silicone rubber which has an elastic modulus similar to human tissues. Thus, they are intrinsically soft and compliant. Upon air pressurization, they are able to support finger range of motion (ROM) and generate the desired actuation of the finger joints. In this work, the soft actuators were characterized in terms of their blocked tip force, normal and frictional grip force outputs. Combining the soft actuators and flexible textile materials, a soft robotic glove was developed for grasping assistance during ADL for stroke survivors. The glove was evaluated on five healthy participants for its assisted ROM and grip strength. Pilot test was performed in two stroke survivors to evaluate the efficacy of the glove in assisting functional grasping activities. Our results demonstrated that the actuators designed in this study could generate desired force output at a low air pressure. The glove had a high kinematic transparency and did not affect the active ROM of the finger joints when it was being worn by the participants. With the assistance of the glove, the participants were able to perform grasping actions with sufficient assisted ROM and grip strength, without any voluntary effort. Additionally, pilot test on stroke survivors demonstrated that the patient's grasping performance improved with the presence and assistance of the glove. Patient feedback questionnaires also showed high level of patient satisfaction and comfort. In conclusion, this paper

  3. 3D Graphical User Interface on Personal Computer using P5 Data Glove

    OpenAIRE

    Ms Khyati r. Nirmal

    2011-01-01

    This paper presents Essential Reality works on 3D HCI for changing 2D visual to 3D visual. The mouse is the critical interface to handle 3D graphical objects. Using data glove its possible to put it on like a normal glove and it then acts as an input device that senses finger movements and hand position and orientation (3 coordinates) in real time. The limitation of surface do not allow large no of windows and icons to be positioned on the screen. If more no of windows are forcibly open some ...

  4. Self-reported behaviors and perceptions of Australian paramedics in relation to hand hygiene and gloving practices in paramedic-led health care.

    Science.gov (United States)

    Barr, Nigel; Holmes, Mark; Roiko, Anne; Dunn, Peter; Lord, Bill

    2017-07-01

    Noncompliance with recommended hand hygiene and gloving practices by workers in the emergency medical services may contribute to the transmission of health care-associated infections and lead to poor patient outcomes. The aim of this study was to explore the self-reported behaviors and perceptions of Australian paramedics in relation to their hand hygiene and gloving practices in paramedic-led health care. A national online survey (n = 417; 17% response rate) and 2 semistructured focus groups (6 per group) were conducted with members of Paramedics Australasia. Although most of the study participants perceived hand hygiene and gloving to be important, the findings suggest poor compliance with both practices, particularly during emergency cases. All participants reported wearing gloves throughout a clinical case, changing them either at the completion of patient care or when visibly soiled or broken. Hand hygiene was missed at defined moments during patient care, possibly from the misuse of gloves. Paramedic hand hygiene and gloving practices require substantial improvement to lower potential transmission of pathogens and improve patient safety and clinical care. Further research is recommended to explore how to alleviate the barriers to performing in-field hand hygiene and the misuse of gloves during paramedic-led health care. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  5. [The usage of protective gloves for routine disinfection of patient contact areas : An anonymous survey of work doctors and hygienists (infection control nurses, link nurses and physicians)].

    Science.gov (United States)

    Dittmann, Kathleen; Morch-Röder, Alexandra; Kramer, Axel; Kagel, Verena; Hübner, Nils-Olaf

    2017-10-01

    Disinfection, routinely carried out in healthcare facilities and known as "ongoing disinfection" or "untargeted disinfection", covers areas that are suspected of being contaminated with pathogen-containing material without being recognizable or visible in individual cases. The use of chemical resistant protective gloves is indispensable for surface disinfection. However, it is unclear if healthcare facilities set specific requirements regarding the selection and application of gloves. The usage of protective gloves for routine disinfection of patient contact areas was assessed in an anonymous cross-sectional study. Work doctors and hygienists (infection control nurses, link nurses and physicians) were queried by questionnaire. Disposable gloves were predominantly used, in most cases largely in accordance with EN 374. The most common glove material was nitrile. Glove change was mostly reported between rooms. Reprocessing of reusable gloves is inconsistent. Several professions are responsible for selecting protective gloves. Procedures for glove selection and application for disinfection of contact surfaces vary between the surveyed institutions. Therefore, more attention has to be paid to these three aspects in the future and these must be included in the hygiene plans.

  6. Effects of pressure, cold and gloves on hand skin temperature and manual performance of divers.

    Science.gov (United States)

    Zander, Joanna; Morrison, James

    2008-09-01

    Cold water immersion and protective gloves are associated with decreased manual performance. Although neoprene gloves slow hand cooling, there is little information on whether they provide sufficient protection when diving in cold water. Nine divers wearing three-fingered neoprene gloves and dry suits were immersed in water at 25 and 4 degrees C, at depths of 0.4 msw (101 kPa altitude adjusted) and 40 msw (497 kPa) in a hyperbaric chamber. Skin temperatures were measured at the fingers, hand, forearm, chest and head. Grip strength, tactile sensitivity and manual dexterity were measured at three time intervals. There was an exponential decay in finger and back of hand skin temperatures with exposure time in 4 degrees C water. Finger and back of hand skin temperatures were lower at 40 msw than at 0.4 msw (P effect of pressure or temperature on grip strength. Tactile sensitivity decreased linearly with finger skin temperature at both pressures. Manual dexterity was not affected by finger skin temperature at 0.4 msw, but decreased with fall in finger skin temperature at 40 msw. Results show that neoprene gloves do not provide adequate thermal protection in 4 degrees C water and that impairment of manual performance is dependent on the type of task, depth and exposure time.

  7. FDM 3D printed coffee glove embedded with flexible electronic

    KAUST Repository

    Bahri, Meznan; Hussain, Muhammad Mustafa; Brahimi, Tayeb; Dahrouj, Hayssam

    2017-01-01

    , in collaboration with the Electrical and Computer Engineering Department at Effat University, and aimed at creating a heating coffee glove product operating on double alkaline batteries using Kapton© as a flexible substrate for the circuit. The circuit and its

  8. Applications of a glove-box ICP-MS for the analysis of nuclear materials

    International Nuclear Information System (INIS)

    Garcia Alonso, J.I.; Babelot, J.F.; Glatz, J.P.; Cromboom, O.; Koch, L.

    1993-01-01

    The relatively new analytical technique, Inductively Coupled Plasma Mass Spectrometry (ICP-MS), has been used for the analysis of nuclear materials stemming from different parts of the nuclear fuel cycle. The original instrument has been modified in order to work with radioactive materials in a glove box. The plasma torch and vacuum interface are situated inside the glove box while the mass spectrometer and associated electronics are outside. Samples analysed include fresh nuclear fuels (natural impurities), spent fuels (fission products and actinides), reprocessing solutions (minor actinides) and leachates of spent fuel and high level waste glasses (natural elements, fission products and actinides). (orig.)

  9. Glove powder's carrying capacity for latex protein: analysis using the ASTM ELISA test.

    Science.gov (United States)

    Beezhold, D; Horton, K; Hickey, V; Daddona, J; Kostyal, D

    2003-01-01

    Glove donning powders carry latex proteins and disperse them into the workplace environment. We have used the ASTM D6499 ELISA to quantify the amount of latex antigen bound to and carried by glove powders. We could differentiate between a small amount of protein actually bound to the powders and a larger amount carried by the powder. Enhanced binding of a major allergen, Hev b 5, to the starch powders was demonstrated by Western blot. The D6499 ELISA is able to measure total latex antigen, soluble and powder bound, simultaneously without the need to centrifuge the samples.

  10. Determination of an Ergonomically Sound Glovebox Glove Port Center Line

    Energy Technology Data Exchange (ETDEWEB)

    Christman, Marissa St John [Los Alamos National Laboratory

    2016-11-30

    Determine an ergonomic glovebox glove port center line location which will be used for standardization in new designs, thus allowing for predictable human work performance, reduced worker exposure to radiation and musculoskeletal injury risks, and improved worker comfort, efficiency, health, and safety.

  11. Determination of an Ergonomically Sound Glovebox Glove Port Center Line

    International Nuclear Information System (INIS)

    Christman, Marissa St; Land, Whitney Morgan

    2016-01-01

    Determine an ergonomic glovebox glove port center line location which will be used for standardization in new designs, thus allowing for predictable human work performance, reduced worker exposure to radiation and musculoskeletal injury risks, and improved worker comfort, efficiency, health, and safety.

  12. Sensing Performance of a Vibrotactile Glove for Deaf-Blind People

    Directory of Open Access Journals (Sweden)

    Albano Carrera

    2017-03-01

    Full Text Available This paper presents a glove designed to assess the viability of communication between a deaf-blind user and his/her interlocutor through a vibrotactile device. This glove is part of the TactileCom system, where communication is bidirectional through a wireless link, so no contact is required between the interlocutors. Responsiveness is higher than with letter by letter wording. The learning of a small set of concepts is simpler and the amount learned can be increased at the user’s convenience. The number of stimulated fingers, the keying frequencies and finger response were studied. Message identification rate was 97% for deaf-blind individuals and 81% for control subjects. Identification by single-finger stimulation was better than by multiple-finger stimulation. The interface proved suitable for communication with deaf-blind individuals and can also be used in other conditions, such as multilingual or noisy environments.

  13. The effects of compression gloves on hand symptoms and hand function in rheumatoid arthritis and hand osteoarthritis: a systematic review.

    Science.gov (United States)

    Hammond, Alison; Jones, Vivienne; Prior, Yeliz

    2016-03-01

    to evaluate the effects of compression gloves in adults with rheumatoid arthritis and hand osteoarthritis. Systematic review of randomized controlled trials identified from MEDLINE, CINAHL, AMED, PEDro, OT Seeker, The Cochrane Library, ISI Web of Knowledge, Science Direct and PubMed from their inceptions to January 2015. Methodological quality of identified trials was evaluated using the PEDro scale by three independent assessors. Effects were summarized descriptively. Four trials (n=8-24; total n=74), comparing night wear of full-length finger compression gloves with placebo gloves, were assessed. Three were of moderate (PEDro score 4-5) and one low (score 3) methodological quality. Effect sizes or standardized mean differences could not be calculated to compare trials due to poor data reporting. In rheumatoid arthritis, finger joint swelling was significantly reduced, but results for pain and stiffness were inconclusive and no differences in grip strength and dexterity were identified. One study reported similar effects in pain, stiffness and finger joint swelling from both compression and thermal placebo gloves. Only one study evaluated gloves in hand osteoarthritis (n=5) with no differences. All the trials identified were small with a high risk of Type I and II errors. Evidence for the effectiveness of compression gloves worn at night is inconclusive in rheumatoid arthritis and hand osteoarthritis. © The Author(s) 2015.

  14. Design and Preliminary Feasibility Study of a Soft Robotic Glove for Hand Function Assistance in Stroke Survivors

    Directory of Open Access Journals (Sweden)

    Hong Kai Yap

    2017-10-01

    Full Text Available Various robotic exoskeletons have been proposed for hand function assistance during activities of daily living (ADL of stroke survivors. However, traditional exoskeletons involve the use of complex rigid systems that impede the natural movement of joints, and thus reduce the wearability and cause discomfort to the user. The objective of this paper is to design and evaluate a soft robotic glove that is able to provide hand function assistance using fabric-reinforced soft pneumatic actuators. These actuators are made of silicone rubber which has an elastic modulus similar to human tissues. Thus, they are intrinsically soft and compliant. Upon air pressurization, they are able to support finger range of motion (ROM and generate the desired actuation of the finger joints. In this work, the soft actuators were characterized in terms of their blocked tip force, normal and frictional grip force outputs. Combining the soft actuators and flexible textile materials, a soft robotic glove was developed for grasping assistance during ADL for stroke survivors. The glove was evaluated on five healthy participants for its assisted ROM and grip strength. Pilot test was performed in two stroke survivors to evaluate the efficacy of the glove in assisting functional grasping activities. Our results demonstrated that the actuators designed in this study could generate desired force output at a low air pressure. The glove had a high kinematic transparency and did not affect the active ROM of the finger joints when it was being worn by the participants. With the assistance of the glove, the participants were able to perform grasping actions with sufficient assisted ROM and grip strength, without any voluntary effort. Additionally, pilot test on stroke survivors demonstrated that the patient's grasping performance improved with the presence and assistance of the glove. Patient feedback questionnaires also showed high level of patient satisfaction and comfort. In

  15. A knitted glove sensing system with compression strain for finger movements

    Science.gov (United States)

    Ryu, Hochung; Park, Sangki; Park, Jong-Jin; Bae, Jihyun

    2018-05-01

    Development of a fabric structure strain sensor has received considerable attention due to its broad application in healthcare monitoring and human–machine interfaces. In the knitted textile structure, it is critical to understand the surface structural deformation from a different body motion, inducing the electrical signal characteristics. Here, we report the electromechanical properties of the knitted glove sensing system focusing on the compressive strain behavior. Compared with the electrical response of the tensile strain, the compressive strain shows much higher sensitivity, stability, and linearity via different finger motions. Additionally, the sensor exhibits constant electrical properties after repeated cyclic tests and washing processes. The proposed knitted glove sensing system can be readily extended to a scalable and cost-effective production due to the use of a commercialized manufacturing system.

  16. Design and characterization of low-cost fabric-based flat pneumatic actuators for soft assistive glove application.

    Science.gov (United States)

    Yap, Hong Kai; Sebastian, Frederick; Wiedeman, Christopher; Yeow, Chen-Hua

    2017-07-01

    We present the design of low-cost fabric-based Hat pneumatic actuators for soft assistive glove application. The soft assistive glove is designed to assist hand impaired patients in performing activities of daily living and rehabilitation. The actuators consist of flexible materials such as fabric and latex bladder. Using zero volume actuation concept, the 2D configuration of the actuators simplifies the manufacturing process and allows the actuators to be more compact. The actuators achieve bi-directional flexion and extension motions. Compared to previously developed inflatable soft actuators, the actuators generate sufficient force and torque to assist in both finger flexion and extension at lower air pressure. Preliminary evaluation results show that the glove is able to provide both active finger flexion and extension assistance for activities of daily living and rehabilitative training.

  17. Gestural Interaction for Virtual Reality Environments through Data Gloves

    Directory of Open Access Journals (Sweden)

    G. Rodriguez

    2017-05-01

    Full Text Available In virtual environments, virtual hand interactions play a key role in interactivity and realism allowing to perform fine motions. Data glove is widely used in Virtual Reality (VR and through simulating a human hands natural anatomy (Avatar’s hands in its appearance and motion is possible to interact with the environment and virtual objects. Recently, hand gestures are considered as one of the most meaningful and expressive signals. As consequence, this paper explores the use of hand gestures as a mean of Human-Computer Interaction (HCI for VR applications through data gloves. Using a hand gesture recognition and tracking method, accurate and real-time interactive performance can be obtained. To verify the effectiveness and usability of the system, an experiment of ease learning based on execution’s time was performed. The experimental results demonstrate that this interaction’s approach does not present problems for people more experienced in the use of computer applications. While people with basic knowledge has some problems the system becomes easy to use with practice.

  18. Computational Analysis of the G-III Laminar Flow Glove

    Science.gov (United States)

    Malik, Mujeeb R.; Liao, Wei; Lee-Rausch, Elizabeth M.; Li, Fei; Choudhari, Meelan M.; Chang, Chau-Lyan

    2011-01-01

    Under NASA's Environmentally Responsible Aviation Project, flight experiments are planned with the primary objective of demonstrating the Discrete Roughness Elements (DRE) technology for passive laminar flow control at chord Reynolds numbers relevant to transport aircraft. In this paper, we present a preliminary computational assessment of the Gulfstream-III (G-III) aircraft wing-glove designed to attain natural laminar flow for the leading-edge sweep angle of 34.6deg. Analysis for a flight Mach number of 0.75 shows that it should be possible to achieve natural laminar flow for twice the transition Reynolds number ever achieved at this sweep angle. However, the wing-glove needs to be redesigned to effectively demonstrate passive laminar flow control using DREs. As a by-product of the computational assessment, effect of surface curvature on stationary crossflow disturbances is found to be strongly stabilizing for the current design, and it is suggested that convex surface curvature could be used as a control parameter for natural laminar flow design, provided transition occurs via stationary crossflow disturbances.

  19. The prevalence of, and factors related to, compliance with glove utilization among nurses in Hospital Universiti Sains Malaysia.

    Science.gov (United States)

    Naing, L; Nordin, R; Musa, R

    2001-09-01

    Increasing risk of HIV infections among health care workers has been a continuing concern. The study was designed to identify the compliance of glove utilization, and factors related to non-compliance. A sample of 150 staff nurses were recruited from the study population of 550 nurses in Hospital Universiti Sains Malaysia. Data were collected by using a structured self-administered questionnaires. The response rate was 98.4%. The study revealed a low compliance (13.5%) of glove utilization (for all 9 procedures), which varied among different procedures (27-97%). Younger nurses and those with shorter duration of working experience had better knowledge of Universal Precautions. Nurses in intensive care unit and operation theatre were better in both knowledge and compliance of glove utilization. The three commonest misconceptions were identified as "selective use of gloves for high risk groups and suspected cases", and "tendency to depend on HIV prevalence". Nurses reported practical problems including administrative and personal related such as "stock irregularity" (46%), "glove not available at the emergency sites" (44%), and "reduction of tactile sensation" (39%). It was concluded that poor knowledge and practical problems were possible responsible factors for the low compliance. A good training for nurses comprising principle and practice of Universal Precautions, updated knowledge of blood and body fluid borne infections and risk and its management, will probably improve the compliance.

  20. Gesture recognition based on computer vision and glove sensor for remote working environments

    Energy Technology Data Exchange (ETDEWEB)

    Chien, Sung Il; Kim, In Chul; Baek, Yung Mok; Kim, Dong Su; Jeong, Jee Won; Shin, Kug [Kyungpook National University, Taegu (Korea)

    1998-04-01

    In this research, we defined a gesture set needed for remote monitoring and control of a manless system in atomic power station environments. Here, we define a command as the loci of a gesture. We aim at the development of an algorithm using a vision sensor and glove sensors in order to implement the gesture recognition system. The gesture recognition system based on computer vision tracks a hand by using cross correlation of PDOE image. To recognize the gesture word, the 8 direction code is employed as the input symbol for discrete HMM. Another gesture recognition based on sensor has introduced Pinch glove and Polhemus sensor as an input device. The extracted feature through preprocessing now acts as an input signal of the recognizer. For recognition 3D loci of Polhemus sensor, discrete HMM is also adopted. The alternative approach of two foregoing recognition systems uses the vision and and glove sensors together. The extracted mesh feature and 8 direction code from the locus tracking are introduced for further enhancing recognition performance. MLP trained by backpropagation is introduced here and its performance is compared to that of discrete HMM. (author). 32 refs., 44 figs., 21 tabs.

  1. The use of aldehyde indicators to determine glutaraldehyde and alkaline glutaraldehyde contamination in chemical protective gloves.

    Science.gov (United States)

    Vo, Evanly; Zhuang, Zhenzhen

    2009-07-01

    The aim of this study was to assess the use of aldehyde indicator pads for detection of glutaraldehyde and alkaline glutaraldehyde permeation through chemical protective gloves under simulated in-use conditions. The quantitative analysis of glutaraldehyde permeation through a glove material was determined for Metricide, Wavicide, and 50% glutaraldehyde following a solvent-desorption process and gas chromatographic analysis. All glutaraldehyde solutions exhibited >99% adsorption (including both the glutaraldehyde oligomers of the reaction product and the excess glutaraldehyde) on the pads over the spiking range 0.05-5.0 microL. Breakthrough times for protective gloves were determined using the Thermo-Hand test method, and found to range from 76 to 150, from 170 to 230, and from 232 to 300 min for Metricide, Wavicide, and 50% glutaraldehyde, respectively. Glutaraldehyde recovery was calculated and ranged from 61 to 80% for all glutaraldehyde solutions. The mass of glutaraldehyde in these solutions at the time of breakthrough detection ranged from 17 to 18, from 18 to 19, and from 19 to 20 microg/cm(2) for Wavicide, 50% glutaraldehyde solution, and Metricide, respectively. Aldehyde indicator pads and the Thermo-Hand test method together should find utility in detecting, collecting, and quantitatively analyzing glutaraldehyde permeation samples through chemical protective gloves under simulated in-use conditions.

  2. Evaluation of protective gloves and working techniques for reducing hand-arm vibration exposure in the workplace.

    Science.gov (United States)

    Milosevic, Matija; McConville, Kristiina M Valter

    2012-01-01

    Operation of handheld power tools results in exposure to hand-arm vibrations, which over time lead to numerous health complications. The objective of this study was to evaluate protective equipment and working techniques for the reduction of vibration exposure. Vibration transmissions were recorded during different work techniques: with one- and two-handed grip, while wearing protective gloves (standard, air and anti-vibration gloves) and while holding a foam-covered tool handle. The effect was examined by analyzing the reduction of transmitted vibrations at the wrist. The vibration transmission was recorded with a portable device using a triaxial accelerometer. The results suggest large and significant reductions of vibration with appropriate safety equipment. Reductions of 85.6% were achieved when anti-vibration gloves were used. Our results indicated that transmitted vibrations were affected by several factors and could be measured and significantly reduced.

  3. Contamination smoke: a simulation of heavy metal containing aerosols from fires in plutonium glove boxes: part II

    International Nuclear Information System (INIS)

    Buijs, K.; Chavane de Dalmassy, B.; Baumgaertner, E.

    1992-01-01

    The study of the dispersion of plutonium bearing aerosols during glove box fires on a laboratory scale has been, in part I of this work, focussed on fires of polymethylmethacrylate (PMMA - the major glove box construction material) whose surfaces were contaminated with cerium-europium oxide powder as a substitute for plutonium-uranium oxide. The present part II completes the study with comparative fire experiments involving contaminated samples of various glove box materials burning in or exposed to the flames of the standardized 0.6 MW fire source previously developed. Beyond spreading of the Ce-Eu-oxide powder as mentioned above, the other important surface contamination process is used, i.e. deposition and subsequent drying of droplets from acid cerium-europium solutions. It is shown that, among the tested materials, and with the exception of synthetic glove rubber, burning PMMA spreads the most radioactive contamination. On the other hand, this potential risk is much lower for fires involving materials contaminated from solution deposition than from powder or pellets. Attempts to measure the airborne contaminant particle sizes did not yield conclusive results. They suggest, however, that contamination from solutions leads to smaller heavy-metal containing aerosol particles than contamination with powder

  4. A quantification of occupational skin exposures and the use of protective gloves among hairdressers in Denmark

    DEFF Research Database (Denmark)

    Lysdal, Susan Hovmand; Johansen, Jeanne Duus; Flyvholm, Mari-Ann

    2012-01-01

    comprising all graduates from hairdressing vocational schools from 1985 to 2007 (n = 7840). The participants received a self-administered postal questionnaire in May 2009, including questions on hairdressing tasks performed in the past week at work and the extent of glove use. A response rate of 67.9% (n...... hairdressers; the extent of wet work and chemical treatments was high, and glove use was inconsistent, especially for certain hair colouring procedures and wet work tasks....

  5. Evaluating the transmitted vibration to operator′s hands hand and effect of protective gloves in real condition, based on International Standard Organization 5349 standard

    Directory of Open Access Journals (Sweden)

    Farhad Forouharmajd

    2016-01-01

    Full Text Available Aims: The objective of this research was an evaluation of hand-held tools vibration acceleration such as circular saw and drill transmitted to operator′s and also to determine the role of glove in vibration reduction of those tools. Materials and Methods: In this study, Bruel and Kjaer Vibration meter with a model of 2231 and its analyzer, 2522, along three types of gloves have been used. Accelerometer transducer installed according to International Standard Organization (ISO 5349:1-2 standards in the case of the operator handles the hand-held tool. In next step, the transducer was placed inside the glove. Results: The results show the most accelerated vibration in axis Y for circular saw while working on Plexiglas. All of the used gloves show a reduction of vibration transmission from tools to hands. Glove of C grouped had a reduction of vibration less than two other groups. Conclusion: Based on ISO 5349-1, 10% of workers who are working with circular saw and drill without using glove will be affiliated to white finger after about 7-12 years. As a whole, the results showed that the anti-vibration gloves should be tested in real conditions before using them.

  6. Penelitian jumlah penggunaan bating agent pada penyamakan kulit sarung tangan (fashion glove) dari kulit kelinci

    OpenAIRE

    Muchtar Lutfi; Widhiati Widhiati; Esti Rahayu; Kasmin Nainggolan

    1994-01-01

    The objective of this research is to identify the quatity of bating agent used in tanning rabbit skins to be glove leather, to make use rabbit skins which can not be tanned to fur rabbit skin leather. The materials used in this research were of 40 pieces of lokal salt preservated rabbit skins originated from Yogyakarta having quality III and IV. They were grouped into four and the groups consisted of ten pieces each were tanned to be fashion glove leather using 4% formaline as pretanning agen...

  7. Penelitian Jumlah Penggunaan Bating Agent Pada Penyamakan Kulit Sarung Tangan (Fashion Glove) Dari Kulit Kelinci

    OpenAIRE

    Lutfi, Muchtar; Widhiati, Widhiati; Rahayu, Esti; Nainggolan, Kasmin

    1994-01-01

    The objective of this research is to identify the quatity of bating agent used in tanning rabbit skins to be glove leather, to make use rabbit skins which can not be tanned to fur rabbit skin leather. The materials used in this research were of 40 pieces of lokal salt preservated rabbit skins originated from Yogyakarta having quality III and IV. They were grouped into four and the groups consisted of ten pieces each were tanned to be fashion glove leather using 4% formaline as pretanning agen...

  8. Using pliers in assembly work: short and long task duration effects of gloves on hand performance capabilities and subjective assessments of discomfort and ease of tool manipulation.

    Science.gov (United States)

    Dianat, Iman; Haslegrave, Christine M; Stedmon, Alex W

    2012-03-01

    The present study investigated the effects of wearing typical industrial gloves on hand performance capabilities (muscle activity, wrist posture, touch sensitivity, hand grip and forearm torque strength) and subjective assessments for an extended duration of performing a common assembly task, wire tying with pliers, which requires a combination of manipulation and force exertion. Three commercially available gloves (cotton, nylon and nitrile gloves) were tested and compared with a bare hand condition while participants performed the simulated assembly task for 2 h. The results showed that wearing gloves significantly increased the muscle activity, wrist deviation, and discomfort whilst reducing hand grip strength, forearm torque strength and touch sensitivity. The combined results showed that the length of time for which gloves are worn does affect hand performance capability and that gloves need to be evaluated in a realistic working context. The results are discussed in terms of selection of gloves for industrial assembly tasks involving pliers. Copyright © 2011 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  9. Design and validation of low-cost assistive glove for hand assessment and therapy during activity of daily living-focused robotic stroke therapy.

    Science.gov (United States)

    Nathan, Dominic E; Johnson, Michelle J; McGuire, John R

    2009-01-01

    Hand and arm impairment is common after stroke. Robotic stroke therapy will be more effective if hand and upper-arm training is integrated to help users practice reaching and grasping tasks. This article presents the design, development, and validation of a low-cost, functional electrical stimulation grasp-assistive glove for use with task-oriented robotic stroke therapy. Our glove measures grasp aperture while a user completes simple-to-complex real-life activities, and when combined with an integrated functional electrical stimulator, it assists in hand opening and closing. A key function is a new grasp-aperture prediction model, which uses the position of the end-effectors of two planar robots to define the distance between the thumb and index finger. We validated the accuracy and repeatability of the glove and its capability to assist in grasping. Results from five nondisabled subjects indicated that the glove is accurate and repeatable for both static hand-open and -closed tasks when compared with goniometric measures and for dynamic reach-to-grasp tasks when compared with motion analysis measures. Results from five subjects with stroke showed that with the glove, they could open their hands but without it could not. We present a glove that is a low-cost solution for in vivo grasp measurement and assistance.

  10. F-16XL Ship #2 in hangar for Laminar Flow Glove mounting

    Science.gov (United States)

    1995-01-01

    NASA's two-seat F-16XL research aircraft is shown in the modification hangar at the Dryden Flight Research Center, Edwards, California, during installation of a titanium 'glove' on the upper surface of its modified left wing. The aircraft subsequently concluded a 13 month-long, 45-flight research program which investigated drawing off a small portion of the boundary-layer air in order to provide laminar -- or smooth -- flow over a major portion of a wing flying at supersonic speeds. A turbo-compressor in the aircraft's fuselage provided suction to draw air through more than 10 million tiny laser-drilled holes in the glove via a manifold system employing 20 valves. Data obtained during the program could assist designers of future high-speed aircraft in developing a more efficient civil transport.

  11. Influence on grip of knife handle surface characteristics and wearing protective gloves.

    Science.gov (United States)

    Claudon, Laurent

    2006-11-01

    Ten subjects were asked to apply maximum torques on knife handles with either their bare hand or their hand wearing a Kevlar fibre protective glove. Four knife handles (2 roughnesses, 2 hardnesses) were tested. Surface electromyograms of 6 upper limb and shoulder muscles were recorded and subject opinions on both knife handle hardness and friction in the hand were also assessed. The results revealed the significant influence of wearing gloves (pgloves greatly increased the torque independently of the other two parameters. Under the bare hand condition, a 90 degrees ShA slightly rough handle provided the greatest torque. Subject opinion agreed with the observed effects on recorded torque values except for the hardness factor, for which a preference for the 70 degrees ShA value over the 90 degrees ShA value emerged.

  12. Effect of poly-hexamethylene biguanide hydrochloride (PHMB) treated non-sterile medical gloves upon the transmission of Streptococcus pyogenes, carbapenem-resistant E. coli, MRSA and Klebsiella pneumoniae from contact surfaces.

    Science.gov (United States)

    Ali, S; Wilson, A P R

    2017-08-17

    Reduction of accidental contamination of the near-patient environment has potential to reduce acquisition of healthcare-associated infection(s). Although medical gloves should be removed when soiled or touching the environment, compliance is variable. The use of antimicrobial-impregnated medical gloves could reduce the horizontal-transfer of bacterial contamination between surfaces. Determine the activity of antimicrobial-impregnated gloves against common hospital pathogens: Streptococcus pyogenes, carbapenem-resistant E.coli (CREC), MRSA and ESBL-producing Klebsiella pneumoniae. Fingerpads (~1cm 2 ) of PHMB-treated and untreated gloves were inoculated with 10 μL (~10 4 colony-forming-units [cfu]) of test-bacteria prepared in heavy-soiling (0.5%BSA), blood or distilled-water (no-soiling) and sampled after 0.25, 1, 10 or 15 min contact-time. Donor surfaces (~1cm 2 computer-keys) contaminated with wet/dry inoculum were touched with the fingerpad of treated/untreated gloves and subsequently pressed onto recipient (uncontaminated) computer-keys. Approximately 4.50log 10 cfu of all bacteria persisted after 15 min on untreated gloves regardless of soil-type. In the absence of soiling, PHMB-treated gloves reduced surface-contamination by ~4.5log 10 cfu (>99.99%) within 10 min of contact-time but only ~2.5log 10 (>99.9%) and ~1.0log 10 reduction respectively when heavy-soiling or blood was present. Gloves became highly-contaminated (~4.52log 10 -4.91log 10 cfu) when handling recently-contaminated computer-keys. Untreated gloves contaminated "recipient" surfaces (~4.5log 10 cfu) while PHMB-treated gloves transferred fewer bacteria (2.4-3.6log 10 cfu). When surface contamination was dry, PHMB gloves transferred fewer bacteria (0.3-0.6log 10 cfu) to "recipient" surfaces than untreated gloves (1.0-1.9log 10 ; P gloves may be useful in preventing dissemination of organisms in the near-patient environment during routine care. However they are not a substitute for

  13. Re-use and life span of gloves | van Palenstein Helderman ...

    African Journals Online (AJOL)

    Re-use and life span of gloves. WH van Palenstein Helderman. Abstract. No Abstract. Full Text: EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about ...

  14. Effects of Gloves, Temperature and Their Interaction on Finger, Hand, and Arm Blood Flow and Skin Temperature: A Pilot Study

    Science.gov (United States)

    Hallbech, M. Susan

    1996-01-01

    The objective of this study is to investigate the effects of cold only, commercially available gloves only, and the combination of gloves and cold on the blood flow and surface (skin) temperature of the medial and proximal phalanxes of digit 3, the metacarpal region of the hand, and the forearm.

  15. Concentrations, Stability, and Isolation of the Furan Fatty Acid 9-(3-Methyl-5-pentylfuran-2-yl)-nonanoic Acid from Disposable Latex Gloves.

    Science.gov (United States)

    Müller, Marco; Hogg, Melanie; Ulms, Kerstin; Vetter, Walter

    2017-09-13

    Because of their antioxidant properties, furan fatty acids (furan-FAs) are valuable minor compounds with a widespread occurrence in all living matter. Unfortunately, pure standards are not readily available, because they usually contribute only 1% to the lipid fraction. A known exception of this is the milky fluid of Hevea brasiliensis, commonly known as latex, in which the furan-FA 9-(3-methyl-5-pentylfuran-2-yl)-nonanoic acid (9M5) contributes about 90% to the triacylglycerides. In this study, we investigated the content of 9M5 in 30 different disposable latex gloves, which ranged from 0.7 to 8.2 mg/g of glove. The light degradability of 9M5 in latex gloves was investigated, and different amounts of 9M5 in disposable latex gloves were attributed to varying exposure time to light. Additionally, over 100 mg of the methyl or ethyl ester of 9M5 (purity of >98%) could be extracted from disposable latex gloves, employing cold extraction and silver ion chromatography. With this method, standards for the quantitation of furan-FAs are obtained easily and rapidly in all laboratories.

  16. Student perceptions and effectiveness of an innovative learning tool: Anatomy Glove Learning System.

    Science.gov (United States)

    Lisk, Kristina; McKee, Pat; Baskwill, Amanda; Agur, Anne M R

    2015-01-01

    A trend in anatomical education is the development of alternative pedagogical approaches to replace or complement experiences in a cadaver laboratory; however, empirical evidence on their effectiveness is often not reported. This study aimed to evaluate the effectiveness of Anatomy Glove Learning System (AGLS), which enables students to learn the relationship between hand structure and function by drawing the structures onto a worn glove with imprinted bones. Massage therapy students (n = 73) were allocated into two groups and drew muscles onto either: (1) the glove using AGLS instructional videos (3D group); or (2) paper with palmar/dorsal views of hand bones during an instructor-guided activity (2D group). A self-confidence measure and knowledge test were completed before, immediately after, and one-week following the learning conditions. Self-confidence of hand anatomy in the 3D group gradually increased (3.2/10, 4.7/10, and 4.8/10), whereas self-confidence in the 2D group began to decline one-week later (3.2/10, 4.4/10, and 3.9/10). Knowledge of hand anatomy improved in both groups immediately after learning, (P learning tool (mean = 8.6 ± 2.2). This study provides evidence demonstrating that AGLS and the traditional 2D learning approach are equally effective in promoting students' self-confidence and knowledge of hand anatomy. © 2014 American Association of Anatomists.

  17. Exposure of amateur gardeners to pesticides via the non-gloved skin per day.

    Science.gov (United States)

    Beránková, Martina; Hojerová, Jarmila; Melegová, Linda

    2017-10-01

    To predict a risk to gardeners not wearing protective gloves, the dermal absorption of three active insecticides was assessed in vitro using porcine ear-skin simulating 1-h handling of diluted plant protection products. Acetamiprid and Pirimicarb were found in the receptor fluid immediately after 1-h skin exposure, whereas Chlorpyrifos-methyl absorbed in the skin was not released into the receptor fluid even after 23 hours. The Estimated Gardener Exposure Level (EGEL) at 23 hours after 1-h exposure for two worst-case scenarios (i) non-gloved hands; (ii) non-gloved hands/uncovered forearms, was (i) 0.002, 0.042, and 0.057; (ii) 0.006, 0.101, and 0.135 mg/kg bw/day for Acetamiprid, Pirimicarb, and Chlorpyrifos-methyl, respectively, although the systemically available Chlorpyrifos-methyl amount, due to retention in the skin, is probably lower than determined. The Gardener Exposure Risk (GER), as a ratio of Acceptable Operator Exposure Level (databased values) to EGEL, for Acetamiprid was (i) 35 and 12-fold higher than the limit 1, so the risk via the skin is assumed to be low. Based on the GER values of (i) 0.83 and 0.18; (ii) 0.34 and 0.07 (i.e.health risk to gardeners handling pesticide products without skin protection. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Space Suit Glove Pressure Garment Metacarpal Joint and Robotic Hand Analysis, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Spacesuit glove pressure garments have been a design challenge for NASA since the inception of spacesuits. The human hand demands a complex range of motions, a close...

  19. NASA Research Announcement Phase 1 Report and Phase 2 Proposal for the Development of a Power Assisted Space Suit Glove Assembly

    Science.gov (United States)

    Cadogan, Dave; Lingo, Bob

    1996-01-01

    In July of 1996, ILC Dover was awarded Phase 1 of a contract for NASA to develop a prototype Power Assisted Space Suit glove to enhance the performance of astronauts during Extra-Vehicular Activity (EVA). This report summarizes the work performed to date on Phase 1, and details the work to be conducted on Phase 2 of the program. Phase 1 of the program consisted of research and review of related technical sources, concept brainstorming, baseline design development, modeling and analysis, component mock-up testing, and test data analysis. ILC worked in conjunction with the University of Maryland's Space Systems Laboratory (SSL) to develop the power assisted glove. Phase 2 activities will focus on the design maturation and the manufacture of a working prototype system. The prototype will be tested and evaluated in conjunction with existing space suit glove technology to determine the performance enhancement anticipated with the implementation of the power assisted joint technology in space suit gloves.

  20. The Language of Glove: Wireless gesture decoder with low-power and stretchable hybrid electronics.

    Directory of Open Access Journals (Sweden)

    Timothy F O'Connor

    Full Text Available This communication describes a glove capable of wirelessly translating the American Sign Language (ASL alphabet into text displayable on a computer or smartphone. The key components of the device are strain sensors comprising a piezoresistive composite of carbon particles embedded in a fluoroelastomer. These sensors are integrated with a wearable electronic module consisting of digitizers, a microcontroller, and a Bluetooth radio. Finite-element analysis predicts a peak strain on the sensors of 5% when the knuckles are fully bent. Fatigue studies suggest that the sensors successfully detect the articulation of the knuckles even when bent to their maximal degree 1,000 times. In concert with an accelerometer and pressure sensors, the glove is able to translate all 26 letters of the ASL alphabet. Lastly, data taken from the glove are used to control a virtual hand; this application suggests new ways in which stretchable and wearable electronics can enable humans to interface with virtual environments. Critically, this system was constructed of components costing less than $100 and did not require chemical synthesis or access to a cleanroom. It can thus be used as a test bed for materials scientists to evaluate the performance of new materials and flexible and stretchable hybrid electronics.

  1. The Language of Glove: Wireless gesture decoder with low-power and stretchable hybrid electronics.

    Science.gov (United States)

    O'Connor, Timothy F; Fach, Matthew E; Miller, Rachel; Root, Samuel E; Mercier, Patrick P; Lipomi, Darren J

    2017-01-01

    This communication describes a glove capable of wirelessly translating the American Sign Language (ASL) alphabet into text displayable on a computer or smartphone. The key components of the device are strain sensors comprising a piezoresistive composite of carbon particles embedded in a fluoroelastomer. These sensors are integrated with a wearable electronic module consisting of digitizers, a microcontroller, and a Bluetooth radio. Finite-element analysis predicts a peak strain on the sensors of 5% when the knuckles are fully bent. Fatigue studies suggest that the sensors successfully detect the articulation of the knuckles even when bent to their maximal degree 1,000 times. In concert with an accelerometer and pressure sensors, the glove is able to translate all 26 letters of the ASL alphabet. Lastly, data taken from the glove are used to control a virtual hand; this application suggests new ways in which stretchable and wearable electronics can enable humans to interface with virtual environments. Critically, this system was constructed of components costing less than $100 and did not require chemical synthesis or access to a cleanroom. It can thus be used as a test bed for materials scientists to evaluate the performance of new materials and flexible and stretchable hybrid electronics.

  2. Evaluation of gloves as a water bag coupling agent for therapeutic ultrasound

    Directory of Open Access Journals (Sweden)

    Lúcio Salustiano de Lima

    2017-03-01

    Full Text Available Abstract Introduction Therapeutic ultrasound (TUS is a widespread modality in physiotherapy, and the water bag technique is a coupling method employed in the presence of anatomical irregularities in the treatment area. The aim of the present study is to evaluate the acoustic attenuation of the water bag and its effectiveness as a TUS coupling agent. Methods The rated output powers (ROPs of the TUS equipment were evaluated based on IEC 61689. Then, a radiation force balance was used to measure ROP with and without a water bag (latex and nitrile gloves filled with deionized water between a TUS transducer and the cone-shaped target of the balance. Each experiment was performed five times for each nominal power (0.5, 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, and 7.0 W and in the following configurations: without the water bag (A, with nitrile gloves and with (B and without (C a height controller, and latex gloves with (D and without (E height controller. ROPs obtained in different media were compared. Results The highest relative error of ROP was 16.72% for 0.5 W. Although the power values of the equipment were within the range recommended by IEC, there was a significant difference between the ROP values measured with A and with B, C and D. Conclusion As intensity differences below 0.5 W/cm2 are considered clinically not relevant, conditions A, B, C, D, or E can be used interchangeably.

  3. Recognition of sign language with an inertial sensor-based data glove.

    Science.gov (United States)

    Kim, Kyung-Won; Lee, Mi-So; Soon, Bo-Ram; Ryu, Mun-Ho; Kim, Je-Nam

    2015-01-01

    Communication between people with normal hearing and hearing impairment is difficult. Recently, a variety of studies on sign language recognition have presented benefits from the development of information technology. This study presents a sign language recognition system using a data glove composed of 3-axis accelerometers, magnetometers, and gyroscopes. Each data obtained by the data glove is transmitted to a host application (implemented in a Window program on a PC). Next, the data is converted into angle data, and the angle information is displayed on the host application and verified by outputting three-dimensional models to the display. An experiment was performed with five subjects, three females and two males, and a performance set comprising numbers from one to nine was repeated five times. The system achieves a 99.26% movement detection rate, and approximately 98% recognition rate for each finger's state. The proposed system is expected to be a more portable and useful system when this algorithm is applied to smartphone applications for use in some situations such as in emergencies.

  4. Simplified Abrasion Test Methodology for Candidate EVA Glove Lay-Ups

    Science.gov (United States)

    Rabel, Emily; Aitchison, Lindsay

    2015-01-01

    During the Apollo Program, space suit outer-layer fabrics were badly abraded after performing just a few extravehicular activities (EVAs). For example, the Apollo 12 commander reported abrasive wear on the boots that penetrated the outer-layer fabric into the thermal protection layers after less than 8 hrs of surface operations. Current plans for the exploration planetary space suits require the space suits to support hundreds of hours of EVA on a lunar or Martian surface, creating a challenge for space suit designers to utilize materials advances made over the last 40 years and improve on the space suit fabrics used in the Apollo Program. Over the past 25 years the NASA Johnson Space Center Crew and Thermal Systems Division has focused on tumble testing as means of simulating wear on the outer layer of the space suit fabric. Most recently, in 2009, testing was performed on 4 different candidate outer layers to gather baseline data for future use in design of planetary space suit outer layers. In support of the High Performance EVA Glove Element of the Next Generation Life Support Project, testing a new configuration was recently attempted in which require 10% of the fabric per replicate of that need in 2009. The smaller fabric samples allowed for reduced per sample cost and flexibility to test small samples from manufacturers without the overhead to have a production run completed. Data collected from this iteration was compared to that taken in 2009 to validate the new test method. In addition the method also evaluated the fabrics and fabric layups used in a prototype thermal micrometeoroid garment (TMG) developed for EVA gloves under the NASA High Performance EVA Glove Project. This paper provides a review of previous abrasion studies on space suit fabrics, details methodologies used for abrasion testing in this particular study, results of the validation study, and results of the TMG testing.

  5. Assessment of the dermal exposure to azoxystrobin among women tending cucumbers in selected Polish greenhouses after restricted entry intervals expired--the role of the protective gloves.

    Science.gov (United States)

    Jurewicz, Joanna; Hanke, Wojciech; Sobala, Wojciech; Ligocka, Danuta

    2009-01-01

    The purpose of our study was to determine the level of skin contamination by azoxystrobin in a group of women tending cucumbers in a vegetable-growing greenhouse after restricted entry intervals expired. Exposure samples were assessed on two days during the spring: first entry on the day after spraying of azoxystrobin and second entry six days later. Dermal exposure was measured by using patches on the outside of clothing and sampling gloves underneath regular working gloves. Pesticide deposited on clothing patches and gloves as a substitute for skin deposition was determined by liquid chromatography and mass spectrometry (LC-MS/MS). The study has shown that workers in a Polish greenhouse are exposed to pesticides at re-entry into the greenhouse after pesticides were sprayed several days earlier. Azoxystrobin has been detected on hands, shoulders and chest. Higher levels of azoxystrobin were found on the cotton gloves of women tending the vegetables than on the patches. The levels decreased (by about 60%) on the patches and increased (by about 250%) on the cotton gloves between the two days of measurement. Women working in a vegetable-growing greenhouse and not directly engaged in the process of spraying experience a measurable dermal exposure to azoxystrobin. The protective gloves constitute a source of secondary exposure rather than protecting employees' hands from contact with the pesticide. More efficient personal protective gloves for proper protection of women working in vegetable greenhouses are needed.

  6. Oxidative reduction of glove box wipers with a downdraft thermal oxidation system

    International Nuclear Information System (INIS)

    Phelps, M.R.; Wilcox, W.A.

    1996-04-01

    Wipers (rags) used for decontamination and glove box cleanup in the Plutonium Finishing Plant often become soaked with acid and plutonium-rich solutions. After use, these wipers are rinsed in a dilute NaOH solution and dried, but the formation of unstable nitrates and the hydrogen gas caused by hydrolysis are concerns that still must be addressed. This report gives the results of testing with a small downdraft thermal oxidation system that was constructed by Pacific Northwest National Laboratory to stabilize glove wiper waste, reduce the waste volume, and reclaim plutonium. Proof-of-principle testing was conducted with eight runs using various combinations of rag moisture and chemical pretreatment. All runs went to planned completion. Results of these tests indicate that the thermal oxidation system has the potential for providing significant reductions in waste volume. Weight reductions of 150:1 were easily obtainable during this project. Modifications could result in weight reductions of over 200:1, with possible volume reductions of 500:1

  7. Standard Test Method for Gravimetric Determination of Nonvolatile Residue from Cleanroom Gloves

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers the determination of solvent extractable nonvolatile residue (NVR) from gloves used in cleanrooms where spacecraft are assembled, cleaned, or tested. 1.2 The NVR of interest is that which can be extracted from gloves using a specified solvent that has been selected for its extracting qualities, or because it is representative of solvents used in the particular facility. Alternative solvents may be used, but since their use may result in different values being generated, they must be identified in the procedure data sheet. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  8. Protection efficacy of gloves against components of the solvent in a sprayed isocyanate coating utilizing a reciprocating permeation panel.

    Science.gov (United States)

    Ceballos, Diana M; Reeb-Whitaker, Carolyn; Sasakura, Miyoko; Dills, Russell; Yost, Michael G

    2015-04-01

    Determine protection effectiveness of 5-mil natural rubber latex (0.13-mm), 5-mil nitrile rubber (0.13-mm), and 13-mil butyl rubber (0.33-mm) glove materials against solvents present in a commonly used automotive clear coat formulation using a novel permeation panel. The latex and nitrile gloves were the type commonly used by local autobody spray painters. Glove materials were tested by spraying an automotive clear coat onto an automated reciprocating permeation panel (permeation panel II). Temperature, relative humidity, and spray conditions were controlled to optimize clear coat loading homogeneity as evaluated by gravimetric analysis. Solvent permeation was measured using charcoal cloth analyzed by the National Institute for Occupational Safety and Health 1501 method. Natural rubber latex allowed 3-5 times the permeation of solvents relative to nitrile rubber for all 10 solvents evaluated: ethyl benzene, 2-heptanone, 1-methoxy-2-propyl acetate, o-xylene, m-xylene, p-xylene, n-butyl acetate, methyl isobutyl ketone, petroleum distillates, and toluene. There is a distinct behavior in solvent permeation before and after the coating dry time. Solvent permeation increased steadily before coating dry time and remained fairly constant after coating dry time. Butyl was not permeated by any of the solvents under the conditions tested. Commonly used 5-mil thick (0.13-mm) latex and nitrile gloves were ineffective barriers to solvents found in a commonly used clear coat formulation. Conversely, 13-mil (0.33-mm) butyl gloves were found to be protective against all solvents in the clear coat formulation. © The Author 2014. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  9. A Novel Approach to Highly Damage Tolerant and Abrasion Resistant EVA Gloves, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — As part of the spacesuit pressure garment, the EVA glove incorporates a silicone pad on the palm for protection of the bladder from cuts and punctures. Repeated...

  10. Strategy for decommissioning of the glove-boxes in the Belgonucleaire Dessel MOX fuel fabrication plant

    International Nuclear Information System (INIS)

    Vandergheynst, Alain; Cuchet, Jean-Marie

    2007-01-01

    Available in abstract form only. Full text of publication follows: BELGONUCLEAIRE has been operating the Dessel plant from the mid-80's at industrial scale. In this period, over 35 metric tons of plutonium (HM) was processed into almost 100 reloads of MOX fuel for commercial West-European Light Water Reactors. In late 2005, the decision was made to stop the production because of the shortage of MOX fuel market remaining accessible to BELGONUCLEAIRE after the successive capacity increases of the MELOX plant (France) and the commissioning of the SMP plant (UK). As a significant part of the decommissioning project of this Dessel plant, about 170 medium-sized glove-boxes are planned for dismantling. In this paper, after having reviewed the different specifications of ±-contaminated waste in Belgium, the authors introduce the different options considered for cleaning, size reduction and packaging of the glove-boxes, and the main decision criteria (process, α-containment, mechanization and radiation protection, safety aspects, generation of secondary waste, etc) are analyzed. The selected strategy consists in using cold cutting techniques and manual operation in shielded disposable glove-tents, and packaging α-waste in 200-liter drums for off-site conditioning and intermediate disposal. (authors)

  11. Role of non-destructive examinations in leak testing of glove boxes for industrial scale plutonium handling at nuclear fuel fabrication facility along with case study

    International Nuclear Information System (INIS)

    Aher, Sachin

    2015-01-01

    Non Destructive Examinations has the prominent role at Nuclear Fuel Fabrication Facilities. Specifically NDE has contributed at utmost stratum in Leak Testing of Glove Boxes and qualifying them as a Class-I confinement for safe Plutonium handling at industrial scale. Advanced Fuel Fabrication Facility, BARC, Tarapur is engaged in fabrication of Plutonium based MOX (PuO 2 , DDUO 2 ) fuel with different enrichments for first core of PFBR reactor. Alpha- Leak Tight Glove Boxes along with HEPA Filters and dynamic ventilation form the promising engineering system for safe and reliable handling of plutonium bearing materials considering the radiotoxicity and risk associated with handling of plutonium. Leak Testing of Glove Boxes which involves the leak detection, leak rectification and leak quantifications is major challenging task. To accomplish this challenge, various Non Destructive Testing methods have assisted in promising way to achieve the stringent leak rate criterion for commissioning of Glove Box facilities for plutonium handling. This paper highlights the Role of various NDE techniques like Soap Solution Test, Argon Sniffer Test, Pressure Drop/Rise Test etc. in Glove Box Leak Testing along with procedure and methodology for effective rectification of leakage points. A Flow Chart consisting of Glove Box leak testing procedure starting from preliminary stage up to qualification stage along with a case study and observations are discussed in this paper. (author)

  12. Development and performance assessment of electrically heating gloves with smart temperature control function.

    Science.gov (United States)

    Ma, Nini; Lu, Yehu; Xu, Fanfei; Dai, Hongqin

    2018-03-27

    A pair of lightweight electrically heating gloves (EHG) with smart temperature control function was developed. To evaluate thermoregulation properties of EHG, human trials were conducted in a climate chamber (2.5 °C, 60% RH). The changes in skin temperature of all fingers and opisthenar and the subjective thermal sensation were recorded in 60 min. The effects of two air velocities (i.e., 0.17 m/s and 0.50 m/s) on the cold protective performance of EHG in scenarios of heating and control were also investigated. For heating scenarios, skin temperature and thermal sensation at all fingers and opisthenar were found significantly higher than those in control conditions. Moreover, the air velocity at 0.50 m/s greatly reduced cold protective performance of the gloves. The research findings can be applied to improve thermal comfort and extend working time for persons in cold environments.

  13. Practice of hand hygiene and use of protective gloves: Differences in the perception between patients and medical staff.

    Science.gov (United States)

    Wałaszek, Marta; Kołpa, Małgorzata; Różańska, Anna; Wolak, Zdzisław; Bulanda, Małgorzata; Wójkowska-Mach, Jadwiga

    2018-03-13

    This study investigated differences in perceptions of hand hygiene and protective glove use among patients and health care workers (HCWs) in Poland. We conducted a survey using an original questionnaire among 462 respondents, including 173 (37.4%) patients and 289 (62.6%) HCWs; HCWs demonstrated poor familiarity with the My 5 Moments for Hand Hygiene. The role of protective gloves in preventing health care-associated infection was overestimated by both patients and HCWs. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  14. Permeation of gasoline, diesel, bioethanol (E85), and biodiesel (B20) fuels through six glove materials.

    Science.gov (United States)

    Chin, Jo-Yu; Batterman, Stuart A

    2010-07-01

    Biofuels and conventional fuels differ in terms of their evaporation rates, permeation rates, and exhaust emissions, which can alter exposures of workers, especially those in the fuel refining and distribution industries. This study investigated the permeation of biofuels (bioethanol 85%, biodiesel 20%) and conventional petroleum fuels (gasoline and diesel) through gloves used in occupational settings (neoprene, nitrile, and Viton) and laboratories (latex, nitrile, and vinyl), as well as a standard reference material (neoprene sheet). Permeation rates and breakthrough times were measured using the American Society for Testing and Materials F739-99 protocol, and fuel and permeant compositions were measured by gas chromatography/mass spectrometry. In addition, we estimated exposures for three occupational scenarios and recommend chemical protective clothing suitable for use with motor fuels. Permeation rates and breakthrough times depended on the fuel-glove combination. Gasoline had the highest permeation rate among the four fuels. Bioethanol (85%) had breakthrough times that were two to three times longer than gasoline through neoprene, nitrile Sol-Vex, and the standard reference materials. Breakthrough times for biodiesel (20%) were slightly shorter than for diesel for the latex, vinyl, nitrile examination, and the standard neoprene materials. The composition of permeants differed from neat fuels, e.g., permeants were significantly enriched in the lighter aromatics including benzene. Viton was the best choice among the tested materials for the four fuels tested. Among the scenarios, fuel truck drivers had the highest uptake via inhalation based on the personal measurements available in the literature, and gasoline station attendants had highest uptake via dermal exposure if gloves were not worn. Appropriate selection and use of gloves can protect workers from dermal exposures; however, current recommendations from the National Institute for Occupational Safety and

  15. APLIKASI TIGA DIMENSI VIRTUAL DENGAN MENGGUNAKAN 5DT DATA GLOVE 5 ULTRA

    Directory of Open Access Journals (Sweden)

    Yulia Yulia

    2008-07-01

    Full Text Available Normal 0 false false false IN X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin-top:0cm; mso-para-margin-right:0cm; mso-para-margin-bottom:10.0pt; mso-para-margin-left:0cm; line-height:115%; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} One of active area in information technology research is development of virtual reality (VR. It is a technology which can simulate real world activities in a virtual world. Virtual reality consists of software and hardware which is usually in the form of device that captures human movement. Then VR sends signal of that movement to computer. The signal will be received and processed and shown on the screen, so that the movement can be simulated. In this research, we develop an application that can receive hand movement input with 5DT Data Glove 5 Ultra and create natural and accurate hand movement animation output for hand opening closing and other gestures. Experiments show that there are some gestures though have different physical shapes but are recognized as the same gestures because of sensor limitation in data glove.   Keywords: data glove, animation, virtual reality

  16. Manual work in cold environments and its impact on selection of materials for protective gloves based on workplace observations.

    Science.gov (United States)

    Irzmańska, Emilia; Wójcik, Paulina; Adamus-Włodarczyk, Agnieszka

    2018-04-01

    This article presents a workplace observations on manual work in cold environments and its impact on the selection of materials for protective gloves. The workplace observations was conducted on 107 workers in 7 companies and involved measurements of the temperature of air and objects in the workplaces; in addition the type of surface and shape of the objects was determined. Laboratory tests were also carried out on 11 materials for protective gloves to be used in cold environments. Protective characteristics, including mechanical properties (wear, cut, tear, and puncture resistance), insulation properties (thermal resistance), functional parameters, and hygienic properties (resistance to surface wetting, material stiffness) were evaluated. Appropriate levels of performance and quality, corresponding to the protective and functional properties of the materials, were determined. Based on the results of manual work and laboratory tests, directions for the selection of materials for the construction of protective gloves were formulated with a view to improving work ergonomics. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Final report for Allied-Signal Aerospace Company, Kansas City Division on protective glove permeation analysis

    International Nuclear Information System (INIS)

    Swearengen, P.M.; Johnson, J.S.; Priante, S.J.

    1990-01-01

    We conducted 25 separate glove fabric permeation studies during this project. The permeations were carried out in the small (1 inch) glass ASTM cell. One other permeation study was carded out with a large (two inch) modified ASTM cell for comparison with the small cell results. We also compared the LLNL procedure from both large and small cells with the standard ASTM test procedure which uses a liquid solution on the breakthrough side of the fabric (the liquid is then sampled on a periodic basis). In all comparisons we observed a close-correlation in breakthrough times between the two procedures and the two cell sizes. In the course of this study, we tested ten different glove materials. These included neoprene (original ASTM round-robin sheet stock, 16 mil thickness), Edmont Sol-Vex (nitrile), Pioneer nitrile, Pioneer Pylox (polyvinyl chloride), North Viton (trademark for fluoroelastomers), North SilverShield (Norfoil, trademark for a flexible metallized laminate), Safety 4 4H (patented plastic laminate), and QRP PolyTuff (polyurethane) 20G-2000 (5 mil), 23G-2300 (1.5 mil), and 25G-2500 (1.5 mil). Three of the glove materials, Viton and Silver Shield (North), and 4H (Safety 4), did not allow any permeation measurable by our system to either 1,2-dichloroethane or 3% diphenylmercury (in 1,2-dichloroethane) for a period greater than six hours. A fourth material, QRP Poly Tuff 2OG-2000, did not allow any measurable penetration of Asilamine (an aromatic diamine) for a time pedod of greater than 4 hours. Breakthrough times and curves were obtained for all other tested materials. Eleven different chemicals were used to challenge the glove materials. These included acetone, Asilamine, 1,2-dichloroethane, dichloromethane, isopropyl alcohol, a mixture of 3% diphenylmercury in 1,2-dichloroethane (w/w), phenol, and lso Verre Stripper, 4,4'-methylenedianil (MDA), 1,3-phenylenediamine (MPDA), and Shell Epon (R) curing agent Z

  18. Design of a cosmetic glove stiffness compensation mechanism for toddler-sized hand prostheses

    NARCIS (Netherlands)

    Bos, R.A.; Plettenburg, D.H.

    2017-01-01

    The addition of a cosmetic glove to an upper limb prosthesis has a distinct effect on the cosmetic value, but its viscoelastic behaviour adds a substantial amount of stiffness and hysteresis to the system. As a result, the overall usability of the prosthesis is degraded. A novel negative

  19. Skin protection in nursing work : promoting the use of gloves and hand alcohol

    NARCIS (Netherlands)

    Jungbauer, FHW; van der Harst, J.J.; Groothoff, J.W.; Coenraads, PJ

    Nursing has been identified as a wet-work occupation, with a high prevalence of occupational irritant contact dermatitis. Reduction of exposure to skin irritants contributes to the prevention of occupational skin disease in nurses. The role of the use of soap and water, hand alcohol and gloves in

  20. [Individual prevention of occupational contact dermatitis: protective gloves and skin protection recommendations as part of the patient management scheme by the public statutory employers' liability insurance].

    Science.gov (United States)

    Wilke, A; Skudlik, C; Sonsmann, F K

    2018-05-02

    The dermatologist's procedure is a pivotal tool for early recognition of occupational contact dermatitis (OCD), for reporting OCD cases to the statutory accident insurance and for treating the diseases. The employer is in charge of implementing skin protection measures at the workplace. However, in terms of an individual prevention approach it may be necessary to propose targeted skin protection recommendations in specific patient cases. The patient's own skin protection behavior significantly contributes to regenerating and maintaining healthy skin. This behavior includes the use of occupational skin products, and in particular the correct use of appropriately selected protective gloves. Protective gloves are the most important personal protective measure in the prevention of OCD. Prevention services, occupational health and safety specialists, occupational physicians and centers specialized in occupational dermatology can support the identification of suitable protective measures. Nowadays, suitable protective gloves exist for (almost) every occupational activity and exposure. However, improper use in practice can become a risk factor by itself for the skin (e. g., incorrectly used gloves). Therefore, it is of utmost importance to identify application errors, to educate patients in terms of skin protection and to motivate them to perform an appropriate skin protection behavior. With particular focus on protective gloves, this article gives an overview of various types, materials and potentially glove-related allergens, presents strategies for reducing occlusion effects and discusses some typical application errors and solutions.

  1. Experimental study on the drying of natural latex medical gloves

    Science.gov (United States)

    Chankrachang, Mano; Yongyingsakthavorn, Pisit; Tohsan, Atitaya; Nontakaew, Udomkiat

    2018-01-01

    The purpose of this research was to study latex film drying at 70 °C using a laboratory drying oven. Two different total solid content (TSC) latex compounds, which 45% TSC and 35% TSC were used. The undried latex films were prepared according to the common procedures used in latex gloves manufacturers, that is, by dry coagulant dipping process. The experimental results such as initial moisture content, the amount of moisture and drying time of latex films in each latex compound formula were determined. After that, the results were projected to calculate on the production capacity expand by 1 million piece/day of natural latex medical gloves. Finally, the rate of moisture entering the latex drying oven and the energy consumption of the drying oven were estimated. The results indicated that when the 35% TSC of latex compound was used. The initial moisture content of latex film was higher than 45% TSC of latex compound about 7%. The drying time of 35% TSC was longer than 45% TSC for 2.5 min and consume more energy about 10%. As a result, the 45% TSC latex compound was the better way to saving energy and managing humidity in the production line. Therefore, it was found to very useful to an approximate design length and size of actual of latex drying oven and the rate of moisture entering the oven as well.

  2. Design, fabrication, operation and modification of a glove box adaptable microwave heating system

    Energy Technology Data Exchange (ETDEWEB)

    Mallik, G K; Gautam, V K; Shivashankaran, G; Behere, P G; Mohan, Anand; Bhargava, V K; Kamath, H S [Advanced Fuel Fabrication Facility, Bhabha Atomic Research Centre, Tarapur (India)

    1999-01-01

    The microwave heating techniques have enormous potential to improve the processing conditions for many radiochemical and radio-metallurgical processes. An update review on the various aspects of development and fabrication of an indigenous microwave heating system and its adaptation to the glove box has been reported in this paper. (author) 3 refs.

  3. Transport properties of carboxylated nitrile butadiene rubber (XNBR)-nanoclay composites; a promising material for protective gloves in occupational exposures.

    Science.gov (United States)

    Mirzaei Aliabadi, Mostafa; Naderi, Ghasem; Shahtaheri, Seyed Jamaleddin; Forushani, Abbas Rahimi; Mohammadfam, Iraj; Jahangiri, Mehdi

    2014-02-28

    This study was conducted in response to one of the research needs of National Institute for Occupational Safety and Health (NIOSH), i.e. the application of nanomaterials and nanotechnology in the field of occupational safety and health. In order to fill this important knowledge gap, the equilibrium solubility and diffusion of carbon tetrachloride and ethyl acetate through carboxylated nitrile butadiene rubber (XNBR)-clay nanocomposite, as a promising new material for chemical protective gloves (or barrier against the transport of organic solvent contaminant), were examined by swelling procedure. Near Fickian diffusion was observed for XNBR based nanocomposites containing different amounts of nanoclay. Decontamination potential is a key factor in development of a new material for reusable chemical protective gloves applications, specifically for routine or highly toxic exposures. A thermal decontamination regime for nanocomposite was developed for the first time. Then, successive cycles of exposure/decontamination for nanocomposite were performed to the maximum 10 cycles for the first time. This result confirms that the two selected solvents cannot deteriorate the rubber-nanoclay interaction and, therefore, such gloves can be reusable after decontamination.

  4. Endocrine disruptive effects of chemicals eluted from nitrile-butadiene rubber gloves using reporter gene assay systems.

    Science.gov (United States)

    Satoh, Kanako; Nonaka, Ryouichi; Ohyama, Ken-ichi; Nagai, Fumiko; Ogata, Akio; Iida, Mitsuru

    2008-03-01

    Disposable gloves made of nitrile-butadiene rubber (NBR) are used for contact with foodstuffs rather than polyvinyl chloride gloves containing di(2-ethylhexyl)phthalate (DEHP), because endocrine-disruptive effects are suspected for phthalate diesters including DEHP. However, 4,4'-butylidenebis(6-t-butyl-m-cresol) (BBBC), 2,4-di-t-butylphenol, and 2,2,4-trimetyl-1,3-pentanediol diisobutyrate can be eluted from NBR gloves, and possibly also detected in food. In this study, we examined the endocrine-disrupting effects of these chemicals via androgen receptor (AR) and estrogen receptor (ER)-mediated pathways using stably transfected reporter gene cell lines expressing AR (AR-EcoScreen system) and ER (MVLN cells), respectively. We also examined the binding activities of these chemicals to AR and ER. The IC50 value of BBBC for antagonistic androgen was in the range of 10(-6)M. The strength of inhibition was about 5 times that of a known androgen antagonist, 1,1'-(2,2-dichloroethylidene)bis[4-chlorobenzene] (p,p'-DDE), and similar to that of bisphenol A. The IC50 value of BBBC for antagonistic estrogen was in the range of 10(-6)M. These results suggest that BBBC and its structural homologue, 4,4'-thiobis(6-t-butyl-m-cresol) are androgen and estrogen antagonists. It is therefore necessary to study these chemicals in vivo, and clarify their effect on the endocrine system.

  5. A new glove-box system for a high-pressure tritium pump

    International Nuclear Information System (INIS)

    Wilson, S.W.; Borree, R.J.; Chambers, D.I.; Chang, Y.; Merrill, J.T.; Souers, P.C.; Wiggins, R.K.

    1988-01-01

    A new glove-box system that was designed around a high-pressure tritium pump is described. The system incorporates new containment ideas such as ''burpler'' passive pressure controls, valves that can be turned from outside the box, inflatable door seals, ferro-fluidic motor-shaft seals, and rapid box-to-hood conversion during cryostaging. Currently under construction, the system will contain nine separate sections with automatic pressure-balancing and venting systems. 3 refs., 5 figs

  6. Smart Kote Glove for Assessment of Scoring Parameters of Dan and Kyu Grade Kendokas

    Directory of Open Access Journals (Sweden)

    Kwangyul Jeong

    2018-02-01

    Full Text Available Kendo is one of the most ancient swordsmanship arts in Japan. The aims of this study are to develop and test an innovative smart Kote glove for assisting the Kendoka to distinguish scoring from non-scoring Kote (wrist strikes. An in-house developed pressure sensing platform was utilized to develop the smart Kote glove. Ten kendo practitioners, comprising of five Dan (black belts equivalent and five Kyu (lower level/ungraded of both genders, participated in this study. The results showed significant differences between Dan and Kyu participants in both accuracy and sharpness of the strikes. Dan grade participants showed higher percentage of hitting the target comparing to Kyu grade (92% and 75% respectively. The percentage of scoring was also significantly higher in Dan (78% than in Kyu (37% grades. The average impact force of scoring by Dan grade (1159 ± 379 N was higher than by Kyu grade (852 ± 429 N.

  7. Validation for radiation sterilization of surgical latex glove

    International Nuclear Information System (INIS)

    Liu Degui

    2002-01-01

    Objective: To determine the optimal radiation mode for sterilization of surgical latex gloves. Methods: The dose distribution in the product loads inside radiation container was measured in different radiation mode. Results: Data of dose distribution in the product load in different radiation mode were obtained. Conclusion: At pre-set height of source working position and within pre-determined dwelling time of each irradiation container staying at the irradiation position, the delivered dose can meet the customers requirement by the radiation mode that, in the half cycle of radiation process, turns the horizontal middle layers of the product to the upper or lower layers, and the upper and lower layers to the middle layers

  8. Augmenting white cane reliability using smart glove for visually impaired people.

    Science.gov (United States)

    Bernieri, Giuseppe; Faramondi, Luca; Pascucci, Federica

    2015-08-01

    The independent mobility problem of visually impaired people has been an active research topic in biomedical engineering: although many smart tools have been proposed, traditional tools (e.g., the white cane) continue to play a prominent role. In this paper a low cost smart glove is presented: the key idea is to minimize the impact in using it by combining the traditional tools with a technological device able to improve the movement performance of the visually impaired people.

  9. Hand hygiene compliance before and after wearing gloves among intensive care unit nurses in Iran.

    Science.gov (United States)

    Ghorbani, Azam; Sadeghi, Leila; Shahrokhi, Akram; Mohammadpour, Asghar; Addo, Mary; Khodadadi, Esmail

    2016-11-01

    Nosocomial infections are considered a major risk factor in hospital wards, and hand hygiene is the first step in their control. An observational study was conducted in 2015 with 200 nurses working in intensive care units in teaching hospitals of Tabriz, Iran. Data were collected by using the Hand Hygiene Observation Tool questionnaire. The researchers monitored nurses' opportunities for hand hygiene during the 8-week period from February 3-April 4, 2015. A total of 1,067 opportunities occurred for hand hygiene before and after wearing gloves. The results show that hand hygiene compliance before wearing gloves is poor among nurses who work in intensive care units (14.8%). Therefore it is necessary to conduct effective interventions through continuing education programs to improve hand hygiene compliance. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  10. Conception of dismantling cell for glove box with alpha contamination

    International Nuclear Information System (INIS)

    Mangin, D.

    1987-01-01

    The new dismantling cell of Valduc treats particularly alpha glove boxes. This cell is conceived to reduce the intervention inside for man with ventilated clothes and to reduce the volume of alpha wastes by utilization of manipulators and appropriate tools. The respect of low level norms (0.1 Ci/ton) for storage of alpha wastes conductes us to make a first decontamination, to ameliorate the detection in quantity of plutonium in the wastes and for wastes with a level upper the norm to make studies on decontamination by Freon 113 [fr

  11. [Evaporation of selected cytotoxic drugs and permeation of protective gloves--research into the occupational risks of health care personnel handling hazardous cytotoxic drugs (CYTO project)].

    Science.gov (United States)

    Dolezalová, L; Odráska, P; Gorná, L; Prudilová, M; Vejpustková, R; Bláha, L

    2009-01-01

    The CYTO project studies an important aspect of healthcare provision -long-term occupational exposure, both threshold and below-threshold, to chemical agents with carcinogenic and mutagenic properties, with the major focus on antineoplastic drugs.This contribution presents experimental results from the first stages of the project's experimental work, i.e. an evaluation of the physico-chemical characteristics of cytostatic agents (evaporation) and an investigation into protective glove permeation. In co-operation with IUTA (Institut für Energie- und Umwelttechnik e.V., Duisburg, Germany), the vapour pressure of paclitaxel, doxorubicin and dacarbazine was measured following OECD guideline No. 104: Vapour pressure curve--vapour pressure balance. Furthermore, the evaporation of cytostatic drugs was examined in actual laboratory conditions by monitoring the airborne concentration using the passive sampling technique. Besides the evaporation of selected drugs, the permeation of cisplatin, cyclophosphamide, doxorubicin, 5-fluorouracil and paclitaxel through different types of gloves (vinyl, latex, nitrile) was assessed. Although our experiments showed relatively slow evaporation of the evaluated cytostatic drugs (the highest pressure in paclitaxel was 0.024 Pa), equilibrium concentrations may go up to milligrams per cubic metre. Nevertheless, analytical measurements of airborne contamination did not confirm these concentration levels. The glove permeation experiments with cytostatics showed good resistance of nitrile gloves (which were impermeable to all five drugs). Other materials should be avoided while handling cytostatic agents (e.g. maximum permeation of cyclophosphamide through latex was 19 microg/sq cm/hr). Although the volatility of cytostatic agents is low, it cannot be neglected considering the chronic character of exposure. However, in order to estimate actual occupational exposure, future research should focus on the development of sensitive analytical

  12. Fundamentos sobre o conhecimento dos aditivos químicos presentes nas luvas de borracha Fundamentals of the knowledge about chemical additives present in rubber gloves

    Directory of Open Access Journals (Sweden)

    Hegles Rosa de Oliveira

    2011-10-01

    Full Text Available FUNDAMENTOS: Uma das causas mais frequentes de dermatite de contato alérgica, de origem ocupacional, são os aditivos da borracha, presentes nos Equipamentos de Proteção Individual. Os aditivos das luvas natural e sintética mais alergênicos são tiurams, mercaptos e carbamatos. OBJETIVO: levantar o nível de conhecimento em relação aos aditivos químicos utilizados na fabricação das luvas de borracha sintética. MÉTODOS: Foi aplicado um questionário aberto a profissionais que trabalham com fabricação, pesquisa, prescrição e comercialização das luvas. Foi adotado o método de pesquisa qualitativa. RESULTADOS: Foram entrevistadas 30 pessoas: 4 pesquisadores na área de Medicina do Trabalho, 5 médicos do Trabalho, 2 técnicos de segurança do Trabalho, 1 médico do sindicato de trabalhadores da borracha, 1 engenheiro de Segurança do Trabalho, 1 engenheira de Produção do setor de fabricação de luvas de borracha, 4 empresários importadores de luvas, 1 empresário fabricante de luvas, 3 empresários que comercializavam Equipamentos de Proteção Individual, 3 vendedores de lojas de Equipamentos de Proteção Individual, 2 empresários de lojas que comercializavam produtos para alérgicos e 3 dermatologistas. CONCLUSÃO: O conhecimento da composição química das luvas é pequeno. A rotulagem das luvas, com a descrição da composição química, facilitaria a escolha do melhor tipo de luva para cada pessoa. Esta ação, de baixo custo para as empresas, seria um ganho, do ponto de vista da saúde pública, e teria grande repercussão nos usuários de luvas de borracha.BACKGROUNDS: One of the most frequent causes of allergic contact dermatitis of occupational origin are rubber additives, which are present in Personal Protective Equipment (PPE. The most allergenic additives of natural and synthetic gloves are thiurams, carbamates and mercapto group. OBJECTIVE: To investigate the state of knowledge about the chemical additives

  13. Evaluating the Usability of Pinchigator, a system for Navigating Virtual Worlds using Pinch Gloves

    Science.gov (United States)

    Hamilton, George S.; Brookman, Stephen; Dumas, Joseph D. II; Tilghman, Neal

    2003-01-01

    Appropriate design of two dimensional user interfaces (2D U/I) utilizing the well known WIMP (Window, Icon, Menu, Pointing device) environment for computer software is well studied and guidance can be found in several standards. Three-dimensional U/I design is not nearly so mature as 2D U/I, and standards bodies have not reached consensus on what makes a usable interface. This is especially true when the tools for interacting with the virtual environment may include stereo viewing, real time trackers and pinch gloves instead of just a mouse & keyboard. Over the last several years the authors have created a 3D U/I system dubbed Pinchigator for navigating virtual worlds based on the dVise dV/Mockup visualization software, Fakespace Pinch Gloves and Pohlemus trackers. The current work is to test the usability of the system on several virtual worlds, suggest improvements to increase Pinchigator s usability, and then to generalize about what was learned and how those lessons might be applied to improve other 3D U/I systems.

  14. Ten years incidence of natural rubber latex sensitization and symptoms in a prospective cohort of health care workers using non-powdered latex gloves 2000-2009.

    Science.gov (United States)

    Larese Filon, Francesca; Bochdanovits, Letizia; Capuzzo, Chiara; Cerchi, Roberto; Rui, Francesca

    2014-07-01

    To assess the incidence of sensitization and gloves-related symptoms in 10-year follow-up in a group of health care workers (9,660 person-years) using non-powdered latex gloves from 2000 to 2009 and to examine related factors. We studied 2,053 health care workers in Trieste Hospitals by means of skin prick test for latex extract, patch tests and medical examinations. We report the incidence of latex sensitization among workers using non-powdered latex gloves. The incidence of latex sensitization, rhinitis, asthma, urticaria, irritant and allergic contact dermatitis were 1.0; 0.12; 0.21; 0.72; 2.39 and 2.50 cases per 1,000 person-years, respectively. Respiratory symptoms and urticaria were positively related with latex sensitization (OR = 8.0; 95 % CL 1.27-48.6), with common allergic respiratory symptoms (OR = 4.19; 95 % CL 1.04-16.8) and with familial atopy (OR = 4.47; 95 % CL 1.1-17.9). The incidence of latex sensitization and latex-related symptoms were very low but subjects with allergic symptoms related to common allergens are at higher risk. The use of non-latex gloves is suggested for them.

  15. 76 FR 6683 - Information Related to Risks and Benefits of Powdered Gloves; Request for Comments

    Science.gov (United States)

    2011-02-07

    .... 360f). In their submissions to FDA, the petitioners highlight the adverse health effects that can...) that contain or use donning or dusting powder. FDA is interested in the potential health effects from... resulting in inflammation, granulomas, and adhesions of peritoneal tissue after surgery, as well as glove...

  16. Comparison of mechanical properties of silicone and PVC (polyvinylchloride) cosmetic gloves for articulating hand prostheses

    NARCIS (Netherlands)

    Smit, G.; Plettenburg, D.H.

    2013-01-01

    Current articulating electric and body-powered hands have a lower pinch force (15–34 N) than electric hands with stiff fingers (55–100 N). The cosmetic glove, which covers a hand prosthesis, negatively affects the mechanical efficiency of a prosthesis. The goal of this study is to mechanically

  17. Preparation of irradiated natural rubber latex-styrene copolymer for electrical gloves

    International Nuclear Information System (INIS)

    Made Sumarti Kardha

    2010-01-01

    Research on irradiated natural rubber latex-styrene copolymer to prepare electrical glove have been done. Vulcanization of natural rubber latex (NRL) was done by mixing 2 phr (per hundred of rubber) of normal butyl acrylate (n-BA) emulsion then irradiated with ã-ray "6"0Co at the dose of 30 kGy producing irradiated natural rubber latex (INRL). Natural rubber latex-styrene copolymers (SC) were prepared by mixing NRL and styrene monomer at styrene concentrations of 50 phr, 75 phr, 100 phr, 500 phr and irradiated at the doses of 15 kGy, 30 kGy and 45 kGy, then characterized their latex and film properties to obtain optimum SC of SC50. This optimum SC, SC50 then mixed with IRNL at the weight ratio of 0/100, 30/70, 50/50, 70/30 and 100/0, to produce irradiated natural rubber latex-styrene copolymer. The properties of copolymer rubber films made by dipping process i.e., % conversion, total solid content, latex viscosity, tensile strength, modulus 300 %, elongation at break, electrical resistance and dielectric constant were then characterized. Characterization result showed that (INRL-SC50) with 50/50 ratio irradiated at the dose of 30 kGy, have % conversion of 80.93 %, electrical resistivity of 1.73 x 10"1"4 Ohm cm and dielectric constant of 2.76 which fulfill the requirement as material for electrical gloves. (author)

  18. Effectiveness of liquid soap vs. chlorhexidine gluconate for the removal of Clostridium difficile from bare hands and gloved hands.

    Science.gov (United States)

    Bettin, K; Clabots, C; Mathie, P; Willard, K; Gerding, D N

    1994-11-01

    To compare liquid soap versus 4% chlorhexidine gluconate in 4% alcohol for the decontamination of bare or gloved hands inoculated with an epidemic strain of Clostridium difficile. C difficile (6.7 log10 colony-forming units [CFU], 47% spores), was seeded onto bare or latex gloved hands of ten volunteers and allowed to dry. Half the volunteers initially washed with soap and half with chlorhexidine, followed by the other agent 1 week later. Cultures were done with Rodac plates at three sites on the hand: finger/thumbtips, the palmar surfaces of the fingers, and the palm. Statistical comparison was by paired Student's t test. On bare hands, soap and chlorhexidine did not differ in residual bacterial counts on the finger/thumbtips (log10 CFU, 2.0 and 2.1, P = NS) and fingers (log10 CFU, 2.4 and 2.5, P = NS). Counts were too high on bare palms to quantitate. On gloved hands, soap was more effective than chlorhexidine on fingers (log10 CFU 1.3 and 1.7, P soap wash than following chlorhexidine wash. These observations support the use of either soap or chlorhexidine as a handwash for removal of C difficile, but efficacy in the prevention of C difficile transmission must be determined by prospective clinical trials.

  19. Wearable sensor glove based on conducting fabric using electrodermal activity and pulse-wave sensors for e-health application.

    Science.gov (United States)

    Lee, Youngbum; Lee, Byungwoo; Lee, Myoungho

    2010-03-01

    Improvement of the quality and efficiency of health in medicine, both at home and the hospital, calls for improved sensors that might be included in a common carrier such as a wearable sensor device to measure various biosignals and provide healthcare services that use e-health technology. Designed to be user-friendly, smart clothes and gloves respond well to the end users for health monitoring. This study describes a wearable sensor glove that is equipped with an electrodermal activity (EDA) sensor, pulse-wave sensor, conducting fabric, and an embedded system. The EDA sensor utilizes the relationship between drowsiness and the EDA signal. The EDA sensors were made using a conducting fabric instead of silver chloride electrodes, as a more practical and practically wearable device. The pulse-wave sensor measurement system, which is widely applied in oriental medicinal practices, is also a strong element in e-health monitoring systems. The EDA and pulse-wave signal acquisition module was constructed by connecting the sensor to the glove via a conductive fabric. The signal acquisition module is then connected to a personal computer that displays the results of the EDA and pulse-wave signal processing analysis and gives accurate feedback to the user. This system is designed for a number of applications for the e-health services, including drowsiness detection and oriental medicine.

  20. Quantification of Transfer of Salmonella from Citrus Fruits to Peel, Edible Portion, and Gloved Hands during Hand Peeling.

    Science.gov (United States)

    Jung, Jiin; Friedrich, Loretta M; Danyluk, Michelle D; Schaffner, Donald W

    2017-06-01

    Although studies have quantified bacterial transfer between hands and various materials, cross-contamination between the surface of fresh citrus fruit and the edible portions during hand peeling has not been reported. This study quantifies transfer of Salmonella to the edible portion of citrus fruit from a contaminated peel during hand peeling. Citrus fruits used for this study were Citrus sinensis (sweet orange) cultivars 'Valencia' and 'Navel', Citrus unshiu (Satsuma mandarins), Citrus reticulata × Citrus paradisi ('Minneola' tangelo or 'Honeybell'), and C. paradisi (grapefruit) cultivar 'Marsh'. An avirulent Salmonella Typhimurium LT2 (ATCC 700720) resistant to rifampin was used for all experiments. The inoculum containing approximately 9 log CFU/mL (50 μL) was spot inoculated onto the equator, stem, or styler of each fruit and allowed to dry for 24 h. Six volunteers put on single-use latex gloves and peeled inoculated fruit. Peel, edible fruit portion, and gloves were collected and enumerated separately. Three replicates of the study were performed in which each volunteer peeled two inoculated fruit of each variety (n = 36 fruit per variety). Cross-contamination from contaminated surface of citrus fruits to edible portion or gloved hands during peeling was affected by inoculation sites. Average Salmonella transfer to the edible portion ranged from 0.16% (Valencia inoculated at the equator) to 5.41% (navel inoculated at the stem). Average Salmonella transfer to gloved hands ranged from 0.41% (grapefruit inoculated at the stem) to 8.97% (navel inoculated at the stem). Most Salmonella remained on the peel of citrus fruits. The average level of Salmonella remaining on the peel ranged from 5.37% (Minneola inoculated at the equator) to 66.3% (Satsuma inoculated at the styler). When grapefruit was inoculated, the Salmonella that remained on the peel showed a bimodal pattern in which some individuals left almost all Salmonella on the peel, while others left

  1. Hazards in the Solar System: Out-of-School Time Student Activities Focused on Engineering Protective Space Gloves

    Science.gov (United States)

    Vaughan, R. G.; Meyer, N.; Anderson, R. B.; Sokol, K.; Nolan, B.; Edgar, L. A.; Gaither, T. A.; Milazzo, M. P.; Clark, J.

    2017-12-01

    "In Good Hands: Engineering Space Gloves" is a new Engineering Adventures® curriculum unit created for students in grades 3-5 in out-of-school time programs. It was designed and created by the Engineering is Elementary® team at the Museum of Science in Boston, MA, in collaboration with subject matter experts at the USGS Astrogeology Science Center and teacher professional development experts at Northern Arizona University's Center for Science Teaching and Learning. As part of the NASA-funded PLANETS (Planetary Learning that Advances the Nexus of Engineering, Technology, and Science) project, the goals for this unit are to introduce students to some of the potential hazards that would be faced by astronauts exploring planetary bodies in the solar system, and to engage students in thinking about how to engineer solutions to these challenges. Potential human health hazards in planetary exploration include: little to no breathable oxygen, exposure to extreme temperatures and pressures, radiation, dusty or toxic environments, and/or high velocity debris. First, students experiment with gloves made of different materials to accomplish tasks like picking up paper clips, entering numbers on a calculator, and using simple tools, while also testing for insulating properties, protection from crushing forces, and resistance to dust contamination. Students explore the trade-offs between form and multiple desired functions, and gain an introduction to materials engineering. Students are then presented with three different missions. Mission 1 is to collect and return a sample from Saturn's moon, Titan; Mission 2 is mining asteroids for useful minerals; and Mission 3 is to build a radio tower on the far side of Earth's moon. Each of these missions exhibits different potential hazards. Based on their previous experiments with different types of glove materials, students develop and test glove designs that will protect astronauts from mission-specific hazards, while still

  2. Resistance of gloves and protective clothing materials to permeation of cytostatic solutions.

    Science.gov (United States)

    Krzemińska, Sylwia; Pośniak, Małgorzata; Szewczyńska, Małgorzata

    2018-01-15

    The objective of the work was to determine the resistance of selected protective clothing and glove materials to permeation of cytostatics such as docetaxel, fluorouracil, and doxorubicin. The following glove materials were used: natural rubber latex (code A), acrylonitrile-butadiene rubber (code B) and chloroprene rubber (code C). In addition, we tested a layered material composed of a non-woven polyester (PES), a polypropylene (PP) film, and a non-woven PP used for protective coats (code D). The cytostatics were analyzed by liquid chromatography with diode array detection. The tested samples were placed in a purpose-built permeation cell modified to be different from that specified in the standard EN 6529:2001. The tested materials were characterized by good resistance to solutions containing 2 out of the 3 selected cytostatics: doxorubicin and 5-fluorouracil, as indicated by a breakthrough time of over 480 min. Equally high resistance to permeation of the third cytostatic (docetaxel) was exhibited by natural rubber latex, acrylonitrile-butadiene rubber, and chloroprene rubber. However, docetaxel permeated much more readily through the clothing layered material, compromising its barrier properties. It was found that the presence of additional components in cytostatic preparations accelerated permeation through material samples, thus deteriorating their barrier properties. Int J Occup Med Environ Health 2018;31(3):341-350. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  3. A test trial irradiation of natural rubber latex on large scale for the production of examination gloves in a production scale

    International Nuclear Information System (INIS)

    Devendra, R.; Kulatunge, S.; Chandralal, H.N.K.K.; Kalyani, N.M.V.; Seneviratne, J.; Wellage, S.

    1996-01-01

    Radiation Vulcanization of natural rubber latex has been developed extensively through various research and development programme. During these investigations many data was collected and from these data it was proved that radiation vulcanized natural rubber latex (RVNRL) can be used as a new material for industry (RVNRL symposium 1989; Makuuchi IAEA report). This material has been extensively tested in making of dipped goods and extruded products. However these investigations were confined only to laboratory experiments and these experiments mainly reflected material properties of RVNRL and only a little was observed about its behavior in actual production scale operation. The present exercise was carried out mainly to study the behavior of the material in production scale by irradiating latex on a large scale and producing gloves in a production scale plant. It was found that RVNRL can be used in conventional glove plants without making major alteration to the plant. Quality of the gloves that were produced using RVNRL is acceptable. It was also found that the small deviation of vulcanization dose will affect the crosslinking density of films. This will drastically reduce the tensile strength of the film. Crosslinking density or pre-vulcanized relax modulus (PRM) at 100% is a reliable property to control the pre vulcanization of latex by radiation

  4. Measurements by A LEAP-Based Virtual Glove for the Hand Rehabilitation

    Directory of Open Access Journals (Sweden)

    Giuseppe Placidi

    2018-03-01

    Full Text Available Hand rehabilitation is fundamental after stroke or surgery. Traditional rehabilitation requires a therapist and implies high costs, stress for the patient, and subjective evaluation of the therapy effectiveness. Alternative approaches, based on mechanical and tracking-based gloves, can be really effective when used in virtual reality (VR environments. Mechanical devices are often expensive, cumbersome, patient specific and hand specific, while tracking-based devices are not affected by these limitations but, especially if based on a single tracking sensor, could suffer from occlusions. In this paper, the implementation of a multi-sensors approach, the Virtual Glove (VG, based on the simultaneous use of two orthogonal LEAP motion controllers, is described. The VG is calibrated and static positioning measurements are compared with those collected with an accurate spatial positioning system. The positioning error is lower than 6 mm in a cylindrical region of interest of radius 10 cm and height 21 cm. Real-time hand tracking measurements are also performed, analysed and reported. Hand tracking measurements show that VG operated in real-time (60 fps, reduced occlusions, and managed two LEAP sensors correctly, without any temporal and spatial discontinuity when skipping from one sensor to the other. A video demonstrating the good performance of VG is also collected and presented in the Supplementary Materials. Results are promising but further work must be done to allow the calculation of the forces exerted by each finger when constrained by mechanical tools (e.g., peg-boards and for reducing occlusions when grasping these tools. Although the VG is proposed for rehabilitation purposes, it could also be used for tele-operation of tools and robots, and for other VR applications.

  5. Measurements by A LEAP-Based Virtual Glove for the Hand Rehabilitation.

    Science.gov (United States)

    Placidi, Giuseppe; Cinque, Luigi; Polsinelli, Matteo; Spezialetti, Matteo

    2018-03-10

    Hand rehabilitation is fundamental after stroke or surgery. Traditional rehabilitation requires a therapist and implies high costs, stress for the patient, and subjective evaluation of the therapy effectiveness. Alternative approaches, based on mechanical and tracking-based gloves, can be really effective when used in virtual reality (VR) environments. Mechanical devices are often expensive, cumbersome, patient specific and hand specific, while tracking-based devices are not affected by these limitations but, especially if based on a single tracking sensor, could suffer from occlusions. In this paper, the implementation of a multi-sensors approach, the Virtual Glove (VG), based on the simultaneous use of two orthogonal LEAP motion controllers, is described. The VG is calibrated and static positioning measurements are compared with those collected with an accurate spatial positioning system. The positioning error is lower than 6 mm in a cylindrical region of interest of radius 10 cm and height 21 cm. Real-time hand tracking measurements are also performed, analysed and reported. Hand tracking measurements show that VG operated in real-time (60 fps), reduced occlusions, and managed two LEAP sensors correctly, without any temporal and spatial discontinuity when skipping from one sensor to the other. A video demonstrating the good performance of VG is also collected and presented in the Supplementary Materials. Results are promising but further work must be done to allow the calculation of the forces exerted by each finger when constrained by mechanical tools (e.g., peg-boards) and for reducing occlusions when grasping these tools. Although the VG is proposed for rehabilitation purposes, it could also be used for tele-operation of tools and robots, and for other VR applications.

  6. Caracterização da hipersensibilidade a luvas de látex em profissionais da odontologia = Rubber latex gloves hypersensitivities in dental workers

    Directory of Open Access Journals (Sweden)

    Flávia Sukekava

    2007-01-01

    Full Text Available As reações alérgicas ao látex vêm aumentando em profissionais da saúde e se manifestam como um incômodo local ou sintomatologia sistêmica. Para conhecer a freqüência das manifestações alérgicas nos usuários de luvas de látex foi realizada busca entre os profissionais da odontologia via aplicação de questionários. Foram aplicados 450questionários e, dentre os respondedores (140, 19% relataram manifestar reações locais ao contato com as luvas de látex e 5% reações sistêmicas a outros produtos de látex. Cerca de 2,5% declararam dermatite de contato e reações sistêmicas (anafiláticas, 1,5% apenas dermatite de contato e 1% sintomas de anafilaxia ao uso das luvas. Vinte por cento dos profissionais atenderam pacientes com alergia ao látex e 29% declararam questionar, durante a anamnese, a respeito de alergia ao látex. As reações alérgicas a luvas de látex foram freqüentes e é objeto de preocupação entre os profissionais da odontologia.Allergic reactions to natural rubber latex have increased in dental practice affecting both the professional and the patients. Allergic reactions may range from skin disease to asthma and anaphylaxis. This study aimed at determining the incidence of latex gloves allergy amongdental care workers. 450 allergy questionnaires were used to collect information on latex gloves reactions and 140 dental works answered them. Latex gloves reaction occurred in 19% of them and 5% reported allergic reactions to other latex products. 2.5% reported symptoms suggesting contact dermatitis and anaphylaxis hypersensitivities, 1.5% contact dermatitis, and 1% reported anaphylaxis symptoms when wearing them. 20% of them had patients who presented symptoms suggestive of anaphylaxis hypersensitivity to rubber gloves latex. Our study confirms that rubber latex gloves reactions are frequent among dental care workers, and dentists must be aware of the latex allergy in dental practice.

  7. The impact of the use of different types of gloves and bare hands for preparation of clean surgical instruments.

    Science.gov (United States)

    Bruna, Camila Quartim de Moraes; Souza, Rafael Queiroz de; Massaia, Irineu Francisco Silva; Cruz, Áurea Silveira; Graziano, Kazuko Uchikawa

    2016-10-10

    to determine if there are differences on the safety of the preparation of clean surgical instruments using different types of gloves and bare hands and evaluate the microbiological load of these preparations without gloves. laboratory procedure with a pragmatic approach, in which the samples were handled with different types of gloves and bare hands. In addition, cytotoxicity assays were carried out by means of the agar diffusion method. Further samples were subjected to microbiological analysis after being handled without gloves. none of the samples showed cytotoxic effect. All microbiological cultures showed growth of microorganisms, but no microorganism has been recovered after autoclaving. there were no differences in the cytotoxic responses regarding the use of different types of gloves and bare hands in the handling of clean surgical instruments, which could entail iatrogenic risk. It is noteworthy that the use of gloves involves increase in the costs of process and waste generation, and the potential allergenic risk to latex. determinar se existe diferenças na segurança do preparo de instrumentais cirúrgicos relacionada ao uso de distintos tipos de luvas e das mãos nuas no preparo, e avaliar a carga microbiológica destes preparados sem luvas. experimento laboratorial com abordagem pragmática, onde amostras foram manipuladas com diferentes tipos de luvas e com as mãos nuas, elaborado teste de citotoxicidade por meio da difusão em ágar. Outras Amostras sofreram análise microbiológica após serem manipuladas sem luvas. nenhuma das amostras apresentou efeito citotóxico. Todas as culturas microbiológicas apresentaram crescimento de microrganismos, embora nenhum microrganismo tenha sido recuperado após a autoclavação. não houve diferenças nas respostas citotóxicas relacionadas ao uso de diferentes tipos de luvas e das mãos nuas na manipulação do instrumental cirúrgico limpo que sinalizasse risco de iatrogenia. Ressalta-se que o uso de luvas

  8. [The optimization of restoration approaches of advanced hand activity using the sensorial glove and the mCIMT method].

    Science.gov (United States)

    Mozheiko, E Yu; Prokopenko, S V; Alekseevich, G V

    To reason the choice of methods of restoration of advanced hand activity depending on severity of motor disturbance in the top extremity. Eighty-eight patients were randomized into 3 groups: 1) the mCIMT group, 2) the 'touch glove' group, 3) the control group. For assessment of physical activity of the top extremity Fugl-Meyer Assessment Upper Extremity, Nine-Hole Peg Test, Motor Assessment Scale were used. Assessment of non-use phenomenon was carried out with the Motor Activity Log scale. At a stage of severe motor dysfunction, there was a restoration of proximal departments of a hand in all groups, neither method was superior to the other. In case of moderate severity of motor deficiency of the upper extremity the most effective was the method based on the principle of biological feedback - 'a touch glove'. In the group with mild severity of motor dysfunction, the best recovery was achieved in the mCIMT group.

  9. Applying a soft-robotic glove as assistive device and training tool with games to support hand function after stroke: Preliminary results on feasibility and potential clinical impact.

    Science.gov (United States)

    Prange-Lasonder, Gerdienke B; Radder, Bob; Kottink, Anke I R; Melendez-Calderon, Alejandro; Buurke, Jaap H; Rietman, Johan S

    2017-07-01

    Recent technological developments regarding wearable soft-robotic devices extend beyond the current application of rehabilitation robotics and enable unobtrusive support of the arms and hands during daily activities. In this light, the HandinMind (HiM) system was developed, comprising a soft-robotic, grip supporting glove with an added computer gaming environment. The present study aims to gain first insight into the feasibility of clinical application of the HiM system and its potential impact. In order to do so, both the direct influence of the HiM system on hand function as assistive device and its therapeutic potential, of either assistive or therapeutic use, were explored. A pilot randomized clinical trial was combined with a cross-sectional measurement (comparing performance with and without glove) at baseline in 5 chronic stroke patients, to investigate both the direct assistive and potential therapeutic effects of the HiM system. Extended use of the soft-robotic glove as assistive device at home or with dedicated gaming exercises in a clinical setting was applicable and feasible. A positive assistive effect of the soft-robotic glove was proposed for pinch strength and functional task performance 'lifting full cans' in most of the five participants. A potential therapeutic impact was suggested with predominantly improved hand strength in both participants with assistive use, and faster functional task performance in both participants with therapeutic application.

  10. NASA Research Announcement Phase 2 Final Report for the Development of a Power Assisted Space Suit Glove

    Science.gov (United States)

    Lingo, Robert; Cadogan, Dave; Sanner, Rob; Sorenson, Beth

    1997-01-01

    The main goal of this program was to develop an unobtrusive power-assisted EVA glove metacarpalphalangeal (MCP) joint that could provide the crew member with as close to nude body performance as possible, and to demonstrate the technology feasibility of power assisted space suit components in general. The MCP joint was selected due to its being representative of other space suit joints, such as the shoulder, hip and carpometacarpal joint, that would also greatly benefit from this technology. In order to meet this objective, a development team of highly skilled and experienced personnel was assembled. The team consisted of two main entities. The first was comprised of ILC's experienced EVA space suit glove designers, who had the responsibility of designing and fabricating a low torque MCP joint which would be compatible with power assisted technology. The second part of the team consisted of space robotics experts from the University of Maryland's Space Systems Laboratory. This team took on the responsibility of designing and building the robotics aspects of the power-assist system. Both parties addressed final system integration responsibilities.

  11. Pegasus(Registered trademark) Wing-Glove Experiment to Document Hypersonic Crossflow Transition: Measurement System and Selected Flight Results

    Science.gov (United States)

    Bertelrud, Arild; delaTova, Geva; Hamory, Philip J.; Young, Ronald; Noffz, Gregory K.; Dodson, Michael; Graves, Sharon S.; Diamond, John K.; Bartlett, James E.; Noack, Robert; hide

    2000-01-01

    In a recent flight experiment to study hypersonic crossflow transition, boundary layer characteristics were documented. A smooth steel glove was mounted on the first stage delta wing of Orbital Sciences Corporation's Pegasus (R) launch vehicle and was flown at speeds of up to Mach 8 and altitudes of up to 250,000 ft. The wing-glove experiment was flown as a secondary payload off the coast of Florida in October 1998. This paper describes the measurement system developed. Samples of the results obtained for different parts of the trajectory are included to show the characteristics and quality of the data. Thermocouples and pressure sensors (including Preston tubes, Stanton tubes, and a "probeless" pressure rake showing boundary layer profiles) measured the time-averaged flow. Surface hot-films and high-frequency pressure transducers measured flow dynamics. Because the vehicle was not recoverable, it was necessary to design a system for real-time onboard processing and transmission. Onboard processing included spectral averaging. The quality and consistency of data obtained was good and met the experiment requirements.

  12. Step-wise integration of single-port laparoscopic surgery into routine colorectal surgical practice by use of a surgical glove port.

    Science.gov (United States)

    Hompes, R; Lindsey, I; Jones, O M; Guy, R; Cunningham, C; Mortensen, N J; Cahill, R A

    2011-06-01

    The cost associated with single-port laparoscopic access devices may limit utilisation of single-port laparoscopic surgery by colorectal surgeons. This paper describes a simple and cheap access modality that has facilitated the widespread adoption of single-port technology in our practice both as a stand-alone procedure and as a useful adjunct to traditional multiport techniques. A surgical glove port is constructed by applying a standard glove onto the rim of the wound protector/retractor used during laparoscopic resectional colorectal surgery. To illustrate its usefulness, we present our total experience to date and highlight a selection of patients presenting for a range of elective colorectal surgery procedures. The surgical glove port allowed successful completion of 25 single-port laparoscopic procedures (including laparoscopic adhesiolysis, ileo-rectal anastomosis, right hemicolectomy, total colectomy and low anterior resection) and has been used as an adjunct in over 80 additional multiport procedures (including refashioning of a colorectal anastomosis made after specimen extraction during a standard multiport laparoscopic anterior resection). This simple, efficient device can allow use of single-port laparoscopy in a broader spectrum of patients either in isolation or in combination with multiport surgery than may be otherwise possible for economic reasons. By separating issues of cost from utility, the usefulness of the technical advance inherent within single-port laparoscopy for colorectal surgery can be better appreciated. We endorse the creative innovation inherent in this approach as surgical practice continues to evolve for ever greater patient benefit.

  13. Design of strong wooden box coated with fiberglass reinforced resin for shipping and burial of contaminated glove boxes. Final report

    International Nuclear Information System (INIS)

    1982-01-01

    The project scope of work included the complete decontamination and decommissioning (D and D) of the Westinghouse ARD Fuel Laboratories at the Cheswick Site in the shortest possible time. This has been accomplished in the following four phases: (1) preparation of documents and necessary paperwork; packaging and shipping of all special nuclear materials in an acceptable form to a reprocessing agency; (2) decontamination of all facilities, glove boxes and equipment; loading of generated waste into bins, barrels and strong wooden boxes; (3) shipping of al bins, barrels and boxes containing waste to the designated burial site; removal of all utility services from the laboratories; and (4) final survey of remaining facilities and certification for nonrestricted use; preparation of final report. This attachment contains design of strong wooden box coated with fiberglass reinforced resin for shipping and burial of contaminated glove boxes

  14. Data Glove System Embedded With Inertial Measurement Units for Hand Function Evaluation in Stroke Patients.

    Science.gov (United States)

    Lin, Bor-Shing; Hsiao, Pei-Chi; Yang, Shu-Yu; Su, Che-Shih; Lee, I-Jung

    2017-11-01

    This paper proposes a data glove system integrated with six-axis inertial measurement unit sensors for evaluating the hand function of patients who have suffered a stroke. The modular design of this data glove facilitates its use for stroke patients. The proposed system can use the hand's accelerations, angular velocities, and joint angles as calculated by a quaternion algorithm, to help physicians gain new insights into rehabilitation treatments. A clinical experiment was performed on 15 healthy subjects and 15 stroke patients whose Brunnstrom stages (BSs) ranged from 4 to 6. In this experiment, the participants were subjected to a grip task, thumb task, and card turning task to produce raw data and three features, namely, the average rotation speed, variation of movement completion time, and quality of movement; these features were extracted from the recorded data to form 2-D and 3-D scatter plots. These scatter plots can provide reference information and guidance to physicians who must determine the BSs of stroke patients. The proposed system demonstrated a hit rate of 70.22% on average. Therefore, this system can effectively reduce physicians' load and provide them with detailed information about hand function to help them adjust rehabilitation strategies for stroke patients.

  15. Refurbishment of isolation room and development of glove box for the DUPIC project in IMEF

    International Nuclear Information System (INIS)

    Baek, S. Y.; Park, J. J.; Lee, H. H.; Hong, K. P.; Yang, M. S.; Min, D. K.

    2001-01-01

    To perform R and D of DUPIC (Direct Use of Spent PWR Fuel in CANDU Reactors), the high-radioactive shielding facility is necessary. IMEF(Irradiated Material Examination Facility) in KAERI has the high-radioactive shielding facility and some R and D such that the spent PWR fuel can be burned again in a PHWR by direct re-fabrication into CANDU-compatible DUPIC fuel bundles, is being carried out using the manipulator attached to the hotcell-M6. Although many testing equipment are located and are being operated in hotcell, it is not possible to work personally inside the hotcell due to the high radioactive contaminant. When they are out of order, the cleaned one can be maintained and repaired using the renovated isolation room located over the hotcell-M6 and the new devised glove box located at service area. Some lead-sheets and the lead glasses were fixed on the wall of the isolation room to improve the shielding capability and the roof door of hotcell-M6 can be open remotely. To maintain and repair the equipment of hotcell, a working desk was constructed in the isolation room. The glove box was also made to withdraw the disordered equipment of hotcell through the rear door

  16. Determination of ring correction factors for leaded gloves used in grab sampling activities at Hanford tank farms

    International Nuclear Information System (INIS)

    RATHBONE, B.A.

    1999-01-01

    This study evaluates the effectiveness of lead lined gloves in reducing extremity dose from two sources specific to tank waste sampling activities: (1) sludge inside glass sample jars and (2) sludge as thin layer contamination on the exterior surface of sample jars. The response of past and present Hanford Extremity Dosimeters (ring) designs under these conditions is also evaluated

  17. Determination of ring correction factors for leaded gloves used in grab sampling activities at Hanford tank farms

    Energy Technology Data Exchange (ETDEWEB)

    RATHBONE, B.A.

    1999-06-24

    This study evaluates the effectiveness of lead lined gloves in reducing extremity dose from two sources specific to tank waste sampling activities: (1) sludge inside glass sample jars and (2) sludge as thin layer contamination on the exterior surface of sample jars. The response of past and present Hanford Extremity Dosimeters (ring) designs under these conditions is also evaluated.

  18. Science Literacy: Hand in Glove with Numeracy

    Directory of Open Access Journals (Sweden)

    Gerry G. Meisels

    2010-07-01

    Full Text Available Science Literacy requires numeracy as part of its foundation, and much of Numeracy draws on examples and applications from the sciences. They share the goal of creating a society that is mathematics numerate and science literate, and are interrelated. National priorities to strengthen both among all our students are driven by practical considerations of economic competitiveness that increasingly depend on technological innovation. It is also critical to each individual for long-term job opportunities and for informed citizenship. With up to 80% of 21st century jobs requiring mathematics and science skills, a large majority of the 2,900,000 students who graduate from America’s high schools every year must become Numerate and Science Literate. Many of these students are not motivated to learn, requiring a change in teaching strategies. Societal will and substantial resources are required to help teachers adopt new approaches that are much more demanding than traditional lectures. Major organizational changes may be needed to strengthen student experience in elementary schools. Advocates of Numeracy and Science Literacy need to work hand in glove to create a citizenry prepared to compete in the 21st century.

  19. Confronting the Gloves-off Economy: America's Broken Labor Standards and How to Fix Them

    OpenAIRE

    Martelle, Scott

    2009-01-01

    Over the last three decades the lowest rungs of American labor have endured a quantum shift in working and living conditions as many employers, aided by lax enforcement, have made a lucrative game of flouting labor and employment laws. But the erosion of protections hasn’t been limited to the working poor. Well before the current economic downturn, the sweatshop ethic expanded broadly throughout the economy, with a wide range of business owners and managers adopting a “gloves-off” approach to...

  20. A novel arctigenin-containing latex glove prevents latex allergy by inhibiting type I/IV allergic reactions.

    Science.gov (United States)

    Wang, Yong-Xin; Xue, Dan-Ting; Liu, Meng; Zhou, Zheng-Min; Shang, Jing

    2016-03-01

    The present study aimed at developing a natural compound with anti-allergic effect and stability under latex glove manufacturing conditions and investigating whether its anti-allergic effect is maintained after its addition into the latex. The effects of nine natural compounds on growth of the RBL-2H3 cells and mouse primary spleen lymphocytes were determined using MTT assay. The compounds included glycyrrhizin, osthole, tetrandrine, tea polyphenol, catechin, arctigenin, oleanolic acid, baicalin and oxymatrine. An ELISA assay was used for the in vitro anti-type I/IV allergy screening; in this process β-hexosaminidase, histamine, and IL-4 released from RBL-2H3 cell lines and IFN-γ and IL-2 released from mouse primary spleen lymphocytes were taken as screening indices. The physical stability of eight natural compounds and the dissolubility of arctigenin, selected based on the in vitro pharnacodynamaic screening and the stability evaluation, were detected by HPLC. The in vivo pharmacodynamic confirmation of arctigenin and final latex product was evaluated with a passive cutaneous anaphylaxis (PCA) model and an allergen-specific skin response model. Nine natural compounds showed minor growth inhibition on RBL-2H3 cells and mouse primary spleen lymphocytes. Baicalin and arctigenin had the best anti-type I and IV allergic effects among the natural compounds based on the in vitro pharmacodynamic screening. Arctigenin and catechin had the best physical stability under different manufacturing conditions. Arctigenin was the selected for further evaluation and proven to have anti-type I and IV allergic effects in vivo in a dose-dependent manner. The final product of the arctigenin-containing latex glove had anti-type I and IV allergic effects in vivo which were mainly attributed to arctigenin as proved from the dissolubility results. Arctigenin showed anti-type I and IV allergic effects in vitro and in vivo, with a good stability under latex glove manufacturing conditions

  1. Investigation on processing technology for tritiated water in glove box

    International Nuclear Information System (INIS)

    Luo Deli; Meng Daqiao

    2002-01-01

    A 0.5 nm molecular sieve absorption column and a hot decomposing magnesium bed was found to be one of the effective means to collect and decompose HTO in glove box atmosphere. The absorption characteristics of the 0.5 nm molecular sieve column and water decomposing characteristics of the hot Mg bed were obtained. The results showed that the column absorbs water vapour from air with efficiency up to 99.99%. Water in tested gases was between 3.4 x 10 3 to 4.2 x 10 3 μg·g -1 and the total water absorbed on the column was up to 162 g, under this condition no water was detected in output gases. Using the hot magnesium bed more than 99.9% desorption water from the column was decomposed

  2. Gloves, gowns and masks for reducing the transmission of meticillin-resistant Staphylococcus aureus (MRSA) in the hospital setting.

    Science.gov (United States)

    López-Alcalde, Jesús; Mateos-Mazón, Marta; Guevara, Marcela; Conterno, Lucieni O; Solà, Ivan; Cabir Nunes, Sheila; Bonfill Cosp, Xavier

    2015-07-16

    Meticillin-resistant Staphylococcus aureus (MRSA; also known as methicillin-resistant S aureus) is a common hospital-acquired pathogen that increases morbidity, mortality, and healthcare costs. Its control continues to be an unresolved issue in many hospitals worldwide. The evidence base for the effects of the use of gloves, gowns or masks as control measures for MRSA is unclear. To assess the effectiveness of wearing gloves, a gown or a mask when contact is anticipated with a hospitalised patient colonised or infected with MRSA, or with the patient's immediate environment. We searched the Specialised Registers of three Cochrane Groups (Wounds Group on 5 June 2015; Effective Practice and Organisation of Care (EPOC) Group on 9 July 2013; and Infectious Diseases Group on 5 January 2009); CENTRAL (The Cochrane Library 2015, Issue 6); DARE, HTA, NHS EED, and the Methodology Register (The Cochrane Library 2015, Issue 6); MEDLINE and MEDLINE In-Process & Other Non-Indexed Citations (1946 to June week 1 2015); EMBASE (1974 to 4 June 2015); Web of Science (WOS) Core Collection (from inception to 7 June 2015); CINAHL (1982 to 5 June 2015); British Nursing Index (1985 to 6 July 2010); and ProQuest Dissertations & Theses Database (1639 to 11 June 2015). We also searched three trials registers (on 6 June 2015), references list of articles, and conference proceedings. We finally contacted relevant individuals for additional studies. Studies assessing the effects on MRSA transmission of the use of gloves, gowns or masks by any person in the hospital setting when contact is anticipated with a hospitalised patient colonised or infected with MRSA, or with the patient's immediate environment. We did not assess adverse effects or economic issues associated with these interventions.We considered any comparator to be eligible. With regard to study design, only randomised controlled trials (clustered or not) and the following non-randomised experimental studies were eligible: quasi

  3. Taking into account seismic risk on glove boxes

    Energy Technology Data Exchange (ETDEWEB)

    Ladurelle, Marie; Philipponneau, Yannick

    2005-01-01

    Built in 1981, the LEFCA is a Basic Nuclear Facility (BNF) in which experimental plutonium based fuels are produced and characterised in about a hundred Gloves Boxes (GB). Many safety rules are required, especially those concerning seismic risk. In order to prepare the December 2003 safety reconsideration, the following methodology has been proposed so that GB might resist the Safe Shutdown Earthquake. 1) The determination of a safety target: the GB static containment. 2) The realisation of an ''in situ'' assessment: the definition of several classes of GB, vibrating table tests and the modelling of the GB behaviour with seismic solicitations, 3) A strength diagnosis for equipment: filters, connecting tunnels and pipes holding. 4) A proposal for further strengthening modifications if necessary : fixing the frame, interlocking GB and the frame, taking internal or external GB missiles into account. This process has contributed to a reduction in the radiological potential seismic impact for the neighbouring populations. We shall present the implemented methodology and the strengthening works that have been approved by Safety Authorities. Reinforcement modifications will begin in 2004. (Author)

  4. Taking into account seismic risk on glove boxes

    International Nuclear Information System (INIS)

    Ladurelle, Marie; Philipponneau, Yannick

    2005-01-01

    Built in 1981, the LEFCA is a Basic Nuclear Facility (BNF) in which experimental plutonium based fuels are produced and characterised in about a hundred Gloves Boxes (GB). Many safety rules are required, especially those concerning seismic risk. In order to prepare the December 2003 safety reconsideration, the following methodology has been proposed so that GB might resist the Safe Shutdown Earthquake. 1) The determination of a safety target: the GB static containment. 2) The realisation of an ''in situ'' assessment: the definition of several classes of GB, vibrating table tests and the modelling of the GB behaviour with seismic solicitations, 3) A strength diagnosis for equipment: filters, connecting tunnels and pipes holding. 4) A proposal for further strengthening modifications if necessary : fixing the frame, interlocking GB and the frame, taking internal or external GB missiles into account. This process has contributed to a reduction in the radiological potential seismic impact for the neighbouring populations. We shall present the implemented methodology and the strengthening works that have been approved by Safety Authorities. Reinforcement modifications will begin in 2004. (Author)

  5. Factors influencing the perception of roughness in manual exploration: Do medical gloves reduce cutaneous sensibility?

    OpenAIRE

    Mylon, P.T.; Buckley-Johnstone, L.; Lewis, R.; Carre, M.J.; Martin, N.

    2015-01-01

    A new roughness perception test was designed to evaluate cutaneous sensibility. Blindfolded subjects explored a sample of sandpaper using one of two methods: stroking the sample (dynamic method) or applying pressure (static method). A range of samples of various grades were presented in a random order, and subjects scored each one in terms of perceived roughness. Each subject performed the test in three conditions – wearing latex and nitrile examination gloves and bare-handed. Mean normalised...

  6. Operating manual for the electrostatic glove-box prefilter installed inside the filter glove box No. 046 at Rocky Flats, Building 776

    International Nuclear Information System (INIS)

    Bergman, W.; Kaifer, R.C.; Hebard, H.D.; Taylor, R.D.; Lum, B.Y.; Boling, R.M.; Buttedahl, O.I.; Woodard, R.W.; Terada, K.

    1979-01-01

    Objective of the evaluation is to evaluate the effectiveness of the electrostatic prefilter in prolonging the life of HEPA (high-efficiency particulate-air) filters. The theory of the electrostatic filter is reviewed, and Glove Box Number 046 is described in detail, followed by a description of the electrostatic prefilter used in the present application. Engineering drawings of the electrostatic prefilter are included. The procedure for evaluating the electrostatic prefilter includes the steps for conducting five different tests: evaluating (1) the HEPA filter alone, (2 and 3) the HEPA filter with a standard prefilter treated both as disposable and reusable, and (4 and 5) the HEPA filter with the electrostatic prefilter, again treated as disposable and reusable. Procedures for flowmeter calibrations and measurements of particle-size distributions are also included. Long-term maintenence of the system during the evaluation program is outlined, and estimates of component durability are given. An electrical engineering safety note describes the high-voltage operational hazard of the electrostatic prefilter and the testing of safety devices

  7. Source term analysis for a criticality accident in metal production line glove boxes

    International Nuclear Information System (INIS)

    Nguyen, D.H.

    1991-06-01

    A recent development in criticality accident analysis is the deterministic calculations of the transport of fission products and actinides through the barriers of the physical facility. The knowledge of the redistribution of the materials inside the facility will help determine the reentry and clean-up procedures. The amount of radioactive materials released to the environment is the source term for dispersion calculations. We have used an integrated computer model to determine the release of fission products to the environment from a hypothetical criticality event in a glove box of the metal production line (MPL) at the Lawrence Livermore National Laboratory (LLNL)

  8. Radiation Vulcanization of Natural Rubber Latex (RVNRL): A Potential Material for Nuclear Power Plant Gloves

    International Nuclear Information System (INIS)

    Pairu Ibrahim; Wan Manshol Wan Zain; Keong, C.C.; Mohd Noorwadi Mat Lazim

    2011-01-01

    Radiation vulcanization of natural rubber latex has great potential for the production of nuclear power plant gloves due to its low ash and mineral content. And this is in-line with the role played by Malaysian Nuclear Agency as Technical Supporting Organization for Nuclear Power Program. This paper discussed the evaluation done to determine ash content in RVNRL and SVNRL films. Both samples were prepared using casting technique and the properties were compared. Films prepared from raw latex without any vulcanizing agent were regarded as a control. (author)

  9. Robotic and nuclear safety for an automated/teleoperated glove box system

    International Nuclear Information System (INIS)

    Domning, E.E.; McMahon, T.T.; Sievers, R.H.

    1991-09-01

    Lawrence Livermore National Laboratory (LLNL) is developing a fully automated system to handle the processing of special nuclear materials (SNM). This work is performed in response to the new goals at the Department of Energy (DOE) for hazardous waste minimization and radiation dose reduction. This fully automated system, called the automated test bed (ATB), consists of an IBM gantry robot and automated processing equipment sealed within a glove box. While the ATB is a cold system, we are designing it as a prototype of the future hot system. We recognized that identification and application of safety requirements early in the design phase will lead to timely installation and approval of the hot system. This paper identifies these safety issues as well as the general safety requirements necessary for the safe operation of the ATB. 4 refs., 2 figs

  10. Unusual presentation of herpes simplex virus infection in a boxer: 'Boxing glove herpes'.

    Science.gov (United States)

    García-García, Begoña; Galache-Osuna, Cristina; Coto-Segura, Pablo; Suárez-Casado, Héctor; Mallo-García, Susana; Jiménez, Jorge Santos-Juanes

    2013-02-01

    Herein, we describe a patient with lesions of cutaneous herpes simplex virus 1 (HSV-1) infection over the knuckles of both hands in the context of an outbreak among boxers. Interestingly, the infection had an unusually long duration (4 weeks), and was not acquired directly through skin-to-skin contact, as it usually does among athletes (herpes gladiatorum). In our case, transmission was acquired through the use of shared boxing gloves contaminated by HSV-1. To the best of our knowledge, herpes gladiatorum, or wrestler's herpes, has not been described previously in boxers and infection over the knuckles is not commonly reported. © 2011 The Authors. Australasian Journal of Dermatology © 2011 The Australasian College of Dermatologists.

  11. Use of impedance threshold device in conjunction with our novel adhesive glove device for ACD-CPR does not result in additional chest decompression.

    Science.gov (United States)

    Shih, Andre; Udassi, Sharda; Porvasnik, Stacy L; Lamb, Melissa A; Badugu, Srinivasarao; Venkata, Giridhar Kaliki; Lopez-Colon, Dalia; Haque, Ikram U; Zaritsky, Arno L; Udassi, Jai P

    2013-10-01

    To evaluate the hemodynamic effects of using an adhesive glove device (AGD) to perform active compression-decompression CPR (AGD-CPR) in conjunction with an impedance threshold device (ITD) in a pediatric cardiac arrest model. Controlled, randomized animal study. In this study, 18 piglets were anesthetized, ventilated, and continuously monitored. After 3min of untreated ventricular fibrillation, animals were randomized (6/group) to receive either standard CPR (S-CPR), active compression-decompression CPR via adhesive glove device (AGD-CPR) or AGD-CPR along with an ITD (AGD-CPR+ITD) for 2min at 100-120compressions/min. AGD is delivered using a fingerless leather glove with a Velcro patch on the palmer aspect and the counter Velcro patch adhered to the pig's chest. Data (mean±SD) were analyzed using one-way ANOVA with pair wise multiple comparisons to assess differences between groups. p-Value≤0.05 was considered significant. Both AGD-CPR and AGD-CPR+ITD groups produced lower intrathoracic pressure (IttP, mmHg) during decompression phase (-13.4±6.7, p=0.01 and -11.9±6.5, p=0.01, respectively) in comparison to S-CPR (-0.3±4.2). Carotid blood flow (CBF, % of baseline mL/min) was higher in AGD-CPR and AGD-CPR+ITD (respectively 64.3±47.3%, p=0.03 and 67.5±33.1%, p=0.04) as compared with S-CPR (29.1±12.5%). Coronary perfusion pressure (CPP, mmHg) was higher in AGD-CPR and AGD-CPR+ITD (respectively 19.7±4.6, p=0.04 and 25.6±12.1, p=0.02) when compared to S-CPR (9.6±9.1). There was no statistically significant difference between AGD-CPR and AGD-CPR+ITD groups with reference to intra-thoracic pressure, carotid blood flow and coronary perfusion pressure. Active compression decompression delivered by this simple and inexpensive adhesive glove device resulted in improved cerebral blood flow and coronary perfusion pressure. There was no statistically significant added effect of ITD use along with AGD-CPR on the decompression of the chest. Copyright © 2013 Elsevier

  12. Contamination control using portable glove bags and containments

    International Nuclear Information System (INIS)

    Fink, C.

    1994-01-01

    Portable gloveboxes and containments have been used in the Navy Nuclear Power programs for many years. Their primary application has been to allow maintenance access to radioactive piping systems while limiting the spread of contamination to the immediate environment. The applications have spread to other areas of the nuclear industry and to other industries with similar contamination control problems. The general application is to keep the contaminants in, but other uses keep the contamination out. The devices can best be classified by material types and construction. They range from the relatively inexpensive polyethylene glove bags for asbestos removal to the semi-permanent aluminum and lexan hard-sided containment structures. There are free-standing open-quotes tentclose quotes structures, support ring devices and tube or bag designs. Only the cost seems to limit the size of these items. The key to the effective use of these devices lies in the planning and control of their application. Proper training of maintenance personnel will greatly facilitate their use, since the main objection seems to be in the exposure received during the rigging of these containments. When all of these considerations are accounted for, a program of contamination control can be quite successful. A brief description of the set-up and use of a specific application is described

  13. Papular-purpuric "gloves and socks" syndrome due to parvovirus B19: report of a case with unusual features

    Directory of Open Access Journals (Sweden)

    PASSONI Luiz Fernando C.

    2001-01-01

    Full Text Available We present a case of papular-purpuric "gloves and socks" syndrome (PPGSS in an adult male with acute parvovirus B19 infection. The patient displayed the classical features of fever, oral lesions, and purpura on hands and feet, but the purpuric lesions on the feet evolved to superficial skin necrosis, a feature not previously described in this syndrome. We believe this is the first reported case of PPGSS occurring in Brazil.

  14. Improving arm function in chronic stroke: a pilot study of sensory amplitude electrical stimulation via glove electrode during task-specific training.

    Science.gov (United States)

    Sullivan, Jane; Girardi, Madeline; Hensley, Melissa; Rohaus, Jordan; Schewe, Clay; Whittey, Colby; Hansen, Piper; Muir, Kimberly

    2015-06-01

    To investigate the effects of sensory amplitude electrical stimulation (SES) delivered by glove electrode during task-specific exercise on arm movement, function, and sensation in chronic stroke. The design was an intervention pilot study, pre-test, post-test, follow-up design. The settings used were a university research laboratory and home-based intervention. Participants comprised of 11 individuals with chronic stroke (7.2 ± 4.1 years post onset) and moderate arm paresis, 10.82/20 ± 2.27 on the Stroke Rehabilitation Assessment of Movement (STREAM) - Arm Subscale. Participants were seven males and four females (mean age: 59 years). Participants were recruited from university-based database. Intervention- Participants engaged in task-specific training at home for 30 min, twice daily, for 5 weeks, while receiving SES via glove electrode. Participants received supervised task practice at least twice during intervention period for 1 hour. Main outcome measures- Jebsen-Taylor Hand Function Test (JTHFT), STREAM - Arm Subscale, Motor Activity Log-14 (MAL-14) - Amount and Quality Subscales, and Nottingham Stereognosis Assessment (NSA). Significant changes were found in group mean pre- and post-test comparisons on the NSA (P = 0.042), MAL amount subscale (P = 0.047), and JTHFT (with writing item 29 excluded) (P = 0.003) and in pre-test to follow-up comparisons on NSA (P = 0.027) and JTHFT (writing item excluded) (P = 0.009). There was no significant change on the STREAM (P = 1.0). Individuals with a greater baseline motor capacity determined by STREAM scores (P = 0.048) and more recent stroke (P = 0.014) had significantly greater improvements. Combining task-specific training with glove-based SES in chronic stroke resulted in changes in arm sensation and function that were maintained at 3-month follow-up.

  15. Job strain among rubber-glove-factory workers in central Thailand.

    Science.gov (United States)

    Sein, Muang Muang; Howteerakul, Nopporn; Suwannapong, Nawarat; Jirachewee, Jirachai

    2010-01-01

    Job strain has become a major concern because of its potential impacts on worker well-being and performance. This cross-sectional study aimed to assess the prevalence of, and examine factors associated with, job strain among workers in a rubber-glove factory, in a central province of Thailand. A total of 200 workers aged 18-55 yr, who had worked at the factory for at least 6 months, completed the Job Content Questionnaire (JCQ) (Thai Version). Two of 5 scales in the JCQ were used to measure job strain, i.e.; job control and psychological job demand. The prevalence of job strain was 27.5%. Multiple logistic regression analysis indicated two variables significantly associated with job strain: low supervisor social support (adjusted OR=3.08; 95%CI: 1.38-6.91) and high job insecurity (adjusted OR=2.25; 95%CI: 1.04-4.88). Effective training for supervisors, to create good relationships among workers and supervisors, and ensuring steady and secure jobs for good employees, are necessary.

  16. Test and Evaluation for Chemical Resistance of Gloves Worn for Protection against Exposure to H-70 Hydrazine.

    Science.gov (United States)

    1980-07-01

    corrected for this discrete sam- pling procedure using the following formula : n-1 C = c + v s I ci Vp i=i where i = an indexing number assigned to...not tested because of their poor resistance to UDMH reported in the NIOSH document (1). Batch and lot were not a consideration at this time; the main...dried material specimen. The weight of an accurately cut 25 cm piece of glove (back of hand) was used to determine the density of the material and hence

  17. Setting up a glove box adoptable high temperature furnace for actinide chemistry research

    International Nuclear Information System (INIS)

    Sali, S.K.; Keskar, Meera; Kannan, S.

    2017-01-01

    Thermophysical and thermochemical properties of fuel materials and the compounds formed by the interaction of fuel with fission products and cladding materials are very important for the understanding of fuel behaviour under reactor operation condition. In order to find out various compounds formed during reactor operating condition, number of phase mixtures containing UO_2, ThO_2, PuO_2 and (U, Pu)O_2 with fission products and cladding materials have to be prepared and characterized using XRD, HTXRD, DSC, TG/DTA techniques. For carrying out solid-state reactions, the reaction mixtures have to be heated in different atmospheres between 1000 to 1600°C.Since, actinides are used in these studies, a control atmosphere high temperature furnace inside a glove box with appropriate safety features is indispensable

  18. Interim report on the activity hold-up and ease of decontamination of permanent coatings and surface treatments incorporated in a glove box floor

    International Nuclear Information System (INIS)

    Dalton, J.T.; Eccles, E.W.; Sutcliffe, P.W.; Turner, A.D.; Dawson, R.K.

    1987-12-01

    A commercial GRP glove box has been equipped with 1 square foot tiles of alternative flooring materials. These comprise highly polished GRP, PEEK, electropolished stainless steel, cold-rolled stainless steel foil, bright nickel electroplate on stainless steel and hard chrome electroplate on stainless steel. The natural GRP finish was used as a reference surface. Standard PuO 2 handling and floor abrasion operations have been carried out on a regular basis. Subsequently, the floor tiles have been decontaminated by swabbing with Arklone soaked tissues and a mass balance has determined the fraction of PuO 2 unaccounted to be about 1%. Hard, smooth surfaces are promising to give the best performance in minimising activity retention under these abrasive conditions to ∼ 100 μg cm -2 . Glove box aerosol concentrations have also been monitored as a function of time after the completion of handling operations by air sampling and by gravity settling. After an initial rapid decrease over ∼ 2 hours, a steady state is reached corresponding to ∼ 1 ng/l of PuO 2 . (author)

  19. Effects of sulfur-based hemostatic agents and gingival retraction cords handled with latex gloves on the polymerization of polyvinyl siloxane impression materials

    Directory of Open Access Journals (Sweden)

    Carlos Eduardo Palhares Machado

    2011-12-01

    Full Text Available OBJECTIVES: This study investigated the possible interactions between three addition silicone materials (Express®, Aquasil Ultra® and Adsil®, three hemostatic agents (ferric sulfate, StatGel FS®; aluminum sulfate, GelCord®; and aluminum chloride, Hemostop® and gingival retraction cords previously handled with latex gloves to determine whether direct contact with medicaments or indirect contamination by latex in conditions similar to those found in clinical practice inhibit or affect the setting of the impression materials. MATERIAL AND METHODS: A portable device for the simultaneous test of several specimens was specifically developed for this study. Polymerization inhibition was analyzed by examination of the impressions and the molded surface. Ten trials were performed for each addition silicone material used in the study, at a total of 240 study samples. RESULTS: All the samples tested (N=240 were nonreactive regardless of the type of combination used. CONCLUSIONS: Aluminum sulfate, ferric sulfate and aluminum chloride hemostatic solutions did not show any inhibitory potential on the addition silicone samples under study, and there were no changes in polymerization as a result of contact between addition silicone and retraction cords handled with latex gloves.

  20. Effects of sulfur-based hemostatic agents and gingival retraction cords handled with latex gloves on the polymerization of polyvinyl siloxane impression materials.

    Science.gov (United States)

    Machado, Carlos Eduardo Palhares; Guedes, Carlos Gramani

    2011-01-01

    This study investigated the possible interactions between three addition silicone materials (Express®, Aquasil Ultra® and Adsil®), three hemostatic agents (ferric sulfate, StatGel FS®; aluminum sulfate, GelCord®; and aluminum chloride, Hemostop®) and gingival retraction cords previously handled with latex gloves to determine whether direct contact with medicaments or indirect contamination by latex in conditions similar to those found in clinical practice inhibit or affect the setting of the impression materials. A portable device for the simultaneous test of several specimens was specifically developed for this study. Polymerization inhibition was analyzed by examination of the impressions and the molded surface. Ten trials were performed for each addition silicone material used in the study, at a total of 240 study samples. All the samples tested (N=240) were nonreactive regardless of the type of combination used. Aluminum sulfate, ferric sulfate and aluminum chloride hemostatic solutions did not show any inhibitory potential on the addition silicone samples under study, and there were no changes in polymerization as a result of contact between addition silicone and retraction cords handled with latex gloves.

  1. Home-based hand rehabilitation with a robotic glove in hemiplegic patients after stroke: a pilot feasibility study.

    Science.gov (United States)

    Bernocchi, Palmira; Mulè, Chiara; Vanoglio, Fabio; Taveggia, Giovanni; Luisa, Alberto; Scalvini, Simonetta

    2018-03-01

    To evaluate the feasibility and safety of home rehabilitation of the hand using a robotic glove, and, in addition, its effectiveness, in hemiplegic patients after stroke. In this non-randomized pilot study, 21 hemiplegic stroke patients (Ashworth spasticity index ≤ 3) were prescribed, after in-hospital rehabilitation, a 2-month home-program of intensive hand training using the Gloreha Lite glove that provides computer-controlled passive mobilization of the fingers. Feasibility was measured by: number of patients who completed the home-program, minutes of exercise and number of sessions/patient performed. Safety was assessed by: hand pain with a visual analog scale (VAS), Ashworth spasticity index for finger flexors, opponents of the thumb and wrist flexors, and hand edema (circumference of forearm, wrist and fingers), measured at start (T0) and end (T1) of rehabilitation. Hand motor function (Motricity Index, MI), fine manual dexterity (Nine Hole Peg Test, NHPT) and strength (Grip test) were also measured at T0 and T1. Patients performed, over a mean period 56 (49-63) days, a total of 1699 (1353-2045) min/patient of exercise with Gloreha Lite, 5.1 (4.3-5.8) days/week. Seventeen patients (81%) completed the full program. The mean VAS score of hand pain, Ashworth spasticity index and hand edema did not change significantly at T1 compared to T0. The MI, NHPT and Grip test improved significantly (p = 0.0020, 0.0156 and 0.0024, respectively) compared to baseline. Gloreha Lite is feasible and safe for use in home rehabilitation. The efficacy data show a therapeutic effect which need to be confirmed by a randomized controlled study.

  2. Interim report on the activity hold-up, and ease of decontamination of permanent coatings and surface treatments incorporated in a glove box floor

    International Nuclear Information System (INIS)

    Dalton, J.T.; Eccles, E.W.; Sutcliffe, P.W.; Turner, A.D.; Dawson, R.K.

    1987-11-01

    A commercial glass reinforced plastic (GRP) glove box has been equipped with 1 square foot tiles of alternative flooring materials. These comprise highly polished GRP, poly-ether-ether-ketone (PEEK), electropolished stainless steel, cold-rolled stainless steel foil, bright nickel electroplate on stainless steel and hard chrome electroplate on stainless steel. The natural GRP finish was used as a reference surface. Standard PuO 2 handling and floor abrasion operations have been carried out on a regular basis. Subsequently, the floor tiles have been decontaminated by swabbing with Arklone soaked tissues and a mass balance has determined the fraction of PuO 2 unaccounted to be about 1%. Hard, smooth surfaces are promising to give the best performance in minimizing activity retention under these abrasive conditions to ∼ 100 μg cm -2 . Glove box aerosol concentrations have also been monitored as a function of time after the completion of handling operations by air sampling and by gravity settling. After an initial rapid decrease over ∼ 2 hours, a steady state is reached corresponding to ∼ 1 ng/l of PuO 2 . (author)

  3. Holdup measurements of plutonium in glove box exhausts

    International Nuclear Information System (INIS)

    Glick, J.B.; Haas, F.X.; McKamy, J.N.; Garrett, A.G.

    1991-01-01

    A new measurement technique has been developed to quantify plutonium in process glove box exhausts. The technique implemented at Rocky Flats Plant utiltizes a shielded, collimated 0.5in. x 0.5in. bismuth germanate (BGO) gamma-ray detector. Pairs of measurements are made at one foot intervals along the duct. One measurement is made with the detector viewing the bottom of the duct with the detector crystal approximately 2 inches from the duct surface. The second measurement is made on the top of the exhaust pipe with the detector crystal 2 inches from the top of the duct. When the detector is placed in the bottom assay position, the area of the holdup material is assumed to extend beyond the detector field of view. The concentration of plutonium in g/cm 2 is obtained from this bottom measurement. The deposit width is determined from a model developed to relate the deposit width to the ratio of the count rates measured at the two positions, above and below the duct. Once a deposit width has been calculated, it is multiplied by the concentration determined from the bottom measurement to yield a mass- per-unit-length at the duct location. Total plutonium mass is then determined by multiplying the duct length by the average of the mass- per-unit length assays performed along the duct. The applicability of the technique is presented in a comparison of field measurement data to analysis results on material removed from the ducts. 3 refs., 3 figs., 1 tab

  4. Development of a disposable force-sensing glove for clinicians and demonstration of its force measurements on patients during rehabilitation following anterior cruciate ligament reconstruction surgery

    Science.gov (United States)

    Wang, Wei-Chih; Linders, David R.; Nuckley, David J.

    2017-12-01

    For many clinicians, their effectiveness is dependent on the magnitude of forces they manually apply to their patients. However, current state-of-the-art care strategies lack quantitative feedback, making it difficult to provide consistent care over time and among multiple clinicians. To provide real-time quantitative feedback to clinicians, we have developed a disposable glove with a force sensor embedded in the fingertips or palm. The sensor is based on the fiber-optic bendloss effect whereby light intensity from an infrared source is attenuated as the fiber is bent between a series of corrugated teeth. The sensor fabricated has a very low profile (10×7×1 mm) and has demonstrated high sensitivity, accuracy, range, and durability. Force feedback up to 90 N with an average force threshold at 0.19 N and average sensor resolution at 0.05 N has been demonstrated. A preliminary clinical study has also been conducted with anterior cruciate ligament reconstruction patients who show significant range of motion improvement when treated with the force-sensing glove.

  5. A Synergy-Based Optimally Designed Sensing Glove for Functional Grasp Recognition.

    Science.gov (United States)

    Ciotti, Simone; Battaglia, Edoardo; Carbonaro, Nicola; Bicchi, Antonio; Tognetti, Alessandro; Bianchi, Matteo

    2016-06-02

    Achieving accurate and reliable kinematic hand pose reconstructions represents a challenging task. The main reason for this is the complexity of hand biomechanics, where several degrees of freedom are distributed along a continuous deformable structure. Wearable sensing can represent a viable solution to tackle this issue, since it enables a more natural kinematic monitoring. However, the intrinsic accuracy (as well as the number of sensing elements) of wearable hand pose reconstruction (HPR) systems can be severely limited by ergonomics and cost considerations. In this paper, we combined the theoretical foundations of the optimal design of HPR devices based on hand synergy information, i.e., the inter-joint covariation patterns, with textile goniometers based on knitted piezoresistive fabrics (KPF) technology, to develop, for the first time, an optimally-designed under-sensed glove for measuring hand kinematics. We used only five sensors optimally placed on the hand and completed hand pose reconstruction (described according to a kinematic model with 19 degrees of freedom) leveraging upon synergistic information. The reconstructions we obtained from five different subjects were used to implement an unsupervised method for the recognition of eight functional grasps, showing a high degree of accuracy and robustness.

  6. A Synergy-Based Optimally Designed Sensing Glove for Functional Grasp Recognition

    Directory of Open Access Journals (Sweden)

    Simone Ciotti

    2016-06-01

    Full Text Available Achieving accurate and reliable kinematic hand pose reconstructions represents a challenging task. The main reason for this is the complexity of hand biomechanics, where several degrees of freedom are distributed along a continuous deformable structure. Wearable sensing can represent a viable solution to tackle this issue, since it enables a more natural kinematic monitoring. However, the intrinsic accuracy (as well as the number of sensing elements of wearable hand pose reconstruction (HPR systems can be severely limited by ergonomics and cost considerations. In this paper, we combined the theoretical foundations of the optimal design of HPR devices based on hand synergy information, i.e., the inter-joint covariation patterns, with textile goniometers based on knitted piezoresistive fabrics (KPF technology, to develop, for the first time, an optimally-designed under-sensed glove for measuring hand kinematics. We used only five sensors optimally placed on the hand and completed hand pose reconstruction (described according to a kinematic model with 19 degrees of freedom leveraging upon synergistic information. The reconstructions we obtained from five different subjects were used to implement an unsupervised method for the recognition of eight functional grasps, showing a high degree of accuracy and robustness.

  7. Reeducação da sensibilidade da mão: desenvolvimento de um modelo de luva sensorial Retraining the sensitivity of the hand: development of a sensory glove model

    Directory of Open Access Journals (Sweden)

    Raquel Metzker Mendes

    2011-01-01

    Full Text Available OBJETIVO: Desenvolver um modelo de luva sensorial e testá-lo em indivíduos não portadores de alterações sensoriais dos membros superiores, treinados a substituir o tato pela audição. MÉTODOS: Para a confecção do equipamento foram utilizados: luva de tecido, minimicrofones, amplificador e fones de ouvido. Sete sujeitos do sexo feminino, idade média de 26,28 anos (±1,03, foram selecionados para utilizar o equipamento e diferenciar texturas após treinamento. O treinamento ocorreu por sete dias, quinze minutos diários e teve como objetivo a identificação de texturas pelo som, utilizando a luva sensorial. Ao final todos os sujeitos responderam a um questionário. RESULTADOS: Todos os sujeitos classificaram o uso da luva como "confortável". Três sujeitos (42% classificaram o aspecto estético do equipamento como "ótimo", dois sujeitos (28,57% como "bom", e dois sujeitos (28,57% como "regular". Seis sujeitos (85,7% identificaram as texturas apenas pelo som e um sujeito (14,3% relatou que foi auxiliado pelo tato. CONCLUSÃO: Foi viável a confecção de um modelo de luva sensorial com tecnologia nacional de fácil acesso e custo relativamente baixo, possibilitando a identificação de texturas pelo som durante o uso do equipamento por indivíduos treinados a substituir o tato pela audição. Nivel de Evidência II, Prospectivo Comparativo.OBJECTIVE: To develop a sensory glove model and test it in subjects with normal sensitivity in the upper limbs, who have been trained to replace hearing with touch. METHODS: To make the equipment, a glove, mini-microphones, amplifier and headphones were used. Seven female subjects, with a mean age of 26.28 years (± 1.03 were selected to use the equipment and differentiate textures after training. The training took place over seven days, fifteen minutes a day, with the aim of identifying textures through sound, using the sensory glove. At the end all subjects answered a questionnaire. RESULTS: All

  8. Distributed Nd-YAG laser welding and process control in inert glove boxes

    International Nuclear Information System (INIS)

    Milewski, J.O.; Lewis, G.K.; Barbe, M.R.; Cremers, D.A.

    1993-01-01

    We have fabricated and assembled a fiber optic delivered ND-YAG laser welding work station that consists of three glove boxes served by a single 1kw laser. Processing considerations related to the welding of special nuclear materials, toxic materials and complex part geometry are addressed within each work cell. We are proceeding with a development effort to integrate the equipment capabilities with remote sensing, process monitoring and control systems. These systems will provide real time data acquisition during welding, monitoring and verification of weld parameters, and CAD/CAM to CNC generated positioning paths. Computerized information storage, retrieval and network methods are used for weld process documentation and data analysis. A virtual control panel is being configured to integrate the monitoring and control operation of individual subsystems, such as laser and motion control into a single graphical interface. Development work on sensors to monitor laser beam characteristics and weld depth in real time with potential for adaptive control is in progress. System capabilities and results of these development efforts are presented

  9. Comparison of the surface contamination of class A shielded containment gloves and a standard shielded containment - professional practices evaluation radiopharmacy Public assistance Marseille hospitals; Comparaison de la contamination de surface des gants d'une enceinte blindee de classe A et d'une enceinte blindee Standard - EPP radiopharmacie APHM

    Energy Technology Data Exchange (ETDEWEB)

    Lopez, V.; Giraud, F.; Pisano, P.; Guillet, B. [CHU Nord, Marseille, Service de radiopharmacie, 13 (France); CHU Timone, service de radiopharmacie, 13 - Marseille (France)

    2010-07-01

    Purpose: The pole of Pharmacy of 'Assistance Publique des Hopitaux de Marseille' initiated a process of evaluation of professional practice. The two functional units of radiopharmacy are involved by comparing the surface contamination of gloves of a class A cell and a standard shielded cell, both in class D premises. Conclusions: In a shielded Class A cell placed in class D premises, there is microbial contamination of gloves probably due to the introduction of not disinfected equipment. In a standard shielded cell where contamination is most important, gloves cleaning should be performed several times during the workday, at least every four hours with a surface bactericidal and fungicidal agent. (N.C.)

  10. Parvovirus B19 infection presenting concurrently as papular-purpuric gloves-and-socks syndrome and bathing-trunk eruption.

    Science.gov (United States)

    Vázquez-Osorio, I; Mallo-García, S; Rodríguez-Díaz, E; Gonzalvo-Rodríguez, P; Requena, L

    2017-01-01

    Parvovirus B19 infection can cause a wide range of cutaneous manifestations, including papular-purpuric gloves-and-socks syndrome (PPGSS) and petechial bathing trunk eruption. We report a case of an immunocompetent woman with a primary parvovirus B19 infection presenting as concurrent PPGSS and petechial bathing trunk eruption. Parvovirus B19 seroconversion was confirmed several days after the onset of the clinical manifestations. The coexistence of these two cutaneous manifestations of primary parvovirus B19 infection has rarely been reported in the literature. It is important to recognize parvovirus B19 infection early, based on the cutaneous manifestations, to avoid potentially serious systemic complications in susceptible individuals. © 2016 British Association of Dermatologists.

  11. Dosimetric evaluation of radiation attenuator glove prototype for containment of radiopharmaceuticals preparation; Evaluation dosimetrique d'un prototype de gant radioattenuateur pour enceintes de preparation des medicaments radiopharmaceutiques

    Energy Technology Data Exchange (ETDEWEB)

    Bouchet, F.; Machefert, N.; Lacoeuille, F.; Le Jeune, J.J.; Couturier, O. [CHU d' Angers, Service de medecine nucleaire, 49 (France); Vannier-Cahouet, A. [CHU d' Angers, Service de pharmacie, 49 (France); Morel, O. [CRLCC Paul-Papin, service de medecine nucleaire, 49 - Angers (France)

    2010-07-01

    The prototype of radio-attenuator glove seems to show an interest in reducing the exposure of the tips for low energy isotopes handling, however these results should be consolidated in order to more accurately estimate the measurement uncertainty of the thermoluminescent dosemeters (T.L.D.) with energy of the isotope. (N.C.)

  12. Design and Evaluation of a Soft and Wearable Robotic Glove for Hand Rehabilitation.

    Science.gov (United States)

    Biggar, Stuart; Yao, Wei

    2016-10-01

    In the modern world, due to an increased aging population, hand disability is becoming increasingly common. The prevalence of conditions such as stroke is placing an ever-growing burden on the limited fiscal resources of health care providers and the capacity of their physical therapy staff. As a solution, this paper presents a novel design for a wearable and adaptive glove for patients so that they can practice rehabilitative activities at home, reducing the workload for therapists and increasing the patient's independence. As an initial evaluation of the design's feasibility the prototype was subjected to motion analysis to compare its performance with the hand in an assessment of grasping patterns of a selection of blocks and spheres. The outcomes of this paper suggest that the theory of design has validity and may lead to a system that could be successful in the treatment of stroke patients to guide them through finger flexion and extension, which could enable them to gain more control and confidence in interacting with the world around them.

  13. Caracterização da hipersensibilidade a luvas de látex em profissionais da odontologia - DOI: 10.4025/actascihealthsci.v29i1.103 Rubber latex gloves hypersensitivities in dental workers - DOI: 10.4025/actascihealthsci.v29i1.103

    Directory of Open Access Journals (Sweden)

    Ana Maria Sell

    2007-12-01

    Full Text Available As reações alérgicas ao látex vêm aumentando em profissionais da saúde e se manifestam como um incômodo local ou sintomatologia sistêmica. Para conhecer a freqüência das manifestações alérgicas nos usuários de luvas de látex foi realizada busca entre os profissionais da odontologia via aplicação de questionários. Foram aplicados 450 questionários e, dentre os respondedores (140, 19% relataram manifestar reações locais ao contato com as luvas de látex e 5% reações sistêmicas a outros produtos de látex. Cerca de 2,5% declararam dermatite de contato e reações sistêmicas (anafiláticas, 1,5% apenas dermatite de contato e 1% sintomas de anafilaxia ao uso das luvas. Vinte por cento dos profissionais atenderam pacientes com alergia ao látex e 29% declararam questionar, durante a anamnese, a respeito de alergia ao látex. As reações alérgicas a luvas de látex foram freqüentes e é objeto de preocupação entre os profissionais da odontologia.Allergic reactions to natural rubber latex have increased in dental practice affecting both the professional and the patients. Allergic reactions may range from skin disease to asthma and anaphylaxis. This study aimed at determining the incidence of latex gloves allergy among dental care workers. 450 allergy questionnaires were used to collect information on latex gloves reactions and 140 dental works answered them. Latex gloves reaction occurred in 19% of them and 5% reported allergic reactions to other latex products. 2.5% reported symptoms suggesting contact dermatitis and anaphylaxis hypersensitivities, 1.5% contact dermatitis, and 1% reported anaphylaxis symptoms when wearing them. 20% of them had patients who presented symptoms suggestive of anaphylaxis hypersensitivity to rubber gloves latex. Our study confirms that rubber latex gloves reactions are frequent among dental care workers, and dentists must be aware of the latex allergy in dental practice.

  14. Study of plutonium fire extinction in glove-boxes; Etude sur l'extinction des feux de plutonium en boites a gants

    Energy Technology Data Exchange (ETDEWEB)

    Boisson, H; Chappellier, A; Debiar, A; Savornin, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    The report concerns attempts to extinguish fire in uranium - chosen as a basis for comparison - and in plutonium, these being contained in glove boxes. The extinguishing powders TEC and MG 10 were tried and compared. The operator used in plastic bags. The metal was dealt with respectively in the form of billets, compact chips and finally thin shavings. In each case fire control was without difficulty. One must allow a certain time for cooling. The powder MG 10 showed very good results. Moreover, the trials proved that densely packed shavings are a very real security factor. The interior lay-out of the glove boxes ought, in order to facilitate further manipulations, be such as to render extinction as easy as possible should the need arise. (authors) [French] II s'agit d'un compte rendu d'essais d'extinction sur feux d'uranium - pris comme base de comparaison - et de plutonium, en boites a gants. Sont utilisees et comparees les poudres extinctrices TEC et MG 10. Elles sont employees par l'operateur en sachets de plastique. Le metal est pris successivement sous forme de billettes, de copeaux compactes, enfin de tournures fines. L'intervention est aisee dans tous les cas; il faut laisser un certain temps de refroidissement. La poudre MG 10 a donne de tres bons resultats, Les essais ont montre, de plus, que le compactage des copeaux est un facteur reel de securite. L'agencement interieur des boites a gants pour les manipulations a venir, devrait tenir compte de cette facilite d'extinction afin de la rendre la plus aisee possible en cas de besoin. (auteurs)

  15. RNA/DNA co-analysis from bloodstains on aged polyvinyl-alcohol gloves prepared for securing evidence from the hands of victims of fatal gunshot injuries.

    Science.gov (United States)

    Grabmüller, Melanie; Courts, Cornelius; Madea, Burkhard; Eichhorst, Tim; Schyma, Christian

    2018-01-01

    In contrast to cumulative techniques (e.g., tape-lift) for qualitative gunshot residues (GSR) analysis, topographic methods are commonly applied to preserve the integrity of evidence from a shooter's or victim's hand in cases of gun-related crimes. Topographic sampling techniques employing adhesive foils, latex, or the polyvinyl alcohol (PVAL) method enable unambiguous sampling of biological and non-biological trace material while preserving its spatial distribution and relation to each other. The PVAL method in particular allows for a topographically veridic and quantitative conservation of traces of GSR and biological stains that are embedded in the PVAL glove, because it completely removes these traces from the hand. The present study investigated the success rates of STR profiling and the detection of blood and brain-specific gene expression from minimal traces of blood splatter as well as parallel to the positive detection of gunshot residues embedded in 17 PVAL gloves taken from the hands of deceased persons in the context of homicide cases in the period between 1996 and 2003. The water-soluble PVAL matrix is shown to be fully compatible with successful STR profiling and the detection of blood- and brain-specific miRNA expression, even after up to 20 years of storage, demonstrating that this sampling technique offers advantages compared to other more simplistic sampling methods like taping.

  16. Handling of a glove box accident. Surgical treatment of a wound contaminated by a mixture of plutonium-239 and americium

    International Nuclear Information System (INIS)

    Lalu, P.

    1977-01-01

    An employee of the Valduc Centre (France) suffered an injury to his right thumb when working in a glove-box on a pipeline which had contained a solution of 239 Pu and Am. The lesion was slight but attempts at decontamination were fruitless. The contamination was deep-seated (activity of not less than 18nCi). DTPA was injected intravenously, and it was decided to excise the lesion surgically. Thanks to the quality of its physical facilities and the professional quality of its radiation medicine and surgery team, the Valduc Centre was able to carry out the operation successfully. The result was excellent, and the contamination was eliminated to the satisfaction of both the patient and the physician. (author)

  17. The European, Japanese and US protective helmet, gloves and boots for firefighters: thermoregulatory and psychological evaluations.

    Science.gov (United States)

    Lee, Joo-Young; Yamamoto, Yota; Oe, Riichi; Son, Su-Young; Wakabayashi, Hitoshi; Tochihara, Yutaka

    2014-01-01

    The purpose of this study was to investigate the physiological and subjective responses of the European, Japanese (JPN) and US firefighters' helmet, gloves and boots for international standardisation. Three experimental conditions were evaluated (clothing mass: 9.4, 8.2 and 10.1 kg for the three conditions, respectively) at the air temperature of 32°C and 60% relative humidity. The results showed that there was no significant difference among the three conditions in oxygen consumption, heart rate, total sweat rate, rectal temperature and mean skin temperature, whereas peripheral temperatures and subjective perceptions were lower in the JPN condition than in the other conditions (P < 0.05). These results indicate that a 0.5-kg reduction in helmet mass and a 1.1-kg reduction in boot mass during exercise resulted in a significant decrease in head and leg temperatures and subjective perceptions, while a 1.9-kg reduction in total clothing mass had insignificant influences on the metabolic burden and overall body temperature.

  18. An Instrumented Glove to Assess Manual Dexterity in Simulation-Based Neurosurgical Education

    Directory of Open Access Journals (Sweden)

    Juan Diego Lemos

    2017-04-01

    Full Text Available The traditional neurosurgical apprenticeship scheme includes the assessment of trainee’s manual skills carried out by experienced surgeons. However, the introduction of surgical simulation technology presents a new paradigm where residents can refine surgical techniques on a simulator before putting them into practice in real patients. Unfortunately, in this new scheme, an experienced surgeon will not always be available to evaluate trainee’s performance. For this reason, it is necessary to develop automatic mechanisms to estimate metrics for assessing manual dexterity in a quantitative way. Authors have proposed some hardware-software approaches to evaluate manual dexterity on surgical simulators. This paper presents IGlove, a wearable device that uses inertial sensors embedded on an elastic glove to capture hand movements. Metrics to assess manual dexterity are estimated from sensors signals using data processing and information analysis algorithms. It has been designed to be used with a neurosurgical simulator called Daubara NS Trainer, but can be easily adapted to another benchtop- and manikin-based medical simulators. The system was tested with a sample of 14 volunteers who performed a test that was designed to simultaneously evaluate their fine motor skills and the IGlove’s functionalities. Metrics obtained by each of the participants are presented as results in this work; it is also shown how these metrics are used to automatically evaluate the level of manual dexterity of each volunteer.

  19. Decontamination and size reduction of plutonium contaminated process exhaust ductwork and glove boxes

    International Nuclear Information System (INIS)

    LaFrate, P.; Elliott, J.; Valasquez, M.

    1996-01-01

    The Los Alamos National Laboratory (LANL) Decommissioning Program has decontaminated and demolished two filter plenum buildings at Technical Area 21 (TA-21). During the project a former hot cell was retrofitted to perform decontamination and size reduction of highly Pu contaminated process exhaust (1,100 ft) and gloveboxes. Pu-238/239 concentrations were as high a 1 Ci per linear foot and averaged approximately 1 mCi/ft. The Project decontamination objective was to reduce the plutonium contamination on surfaces below transuranic levels. If possible, metal surfaces were decontaminated further to meet Science and Ecology Group (SEG) waste classification guidelines to enable the metal to be recycled at their facility in oak Ridge, Tennessee. Project surface contamination acceptance criteria for low-level radioactive waste (LLRW), transuranic waste, and SEG waste acceptance criteria will be presented. Ninety percent of all radioactive waste for the project was characterized as LLRW. Twenty percent of this material was shipped to SEG. Process exhaust and glove boxes were brought to the project decontamination area, an old hot cell in Building 4 North. This paper focuses on process exhaust and glovebox decontamination methodology, size reduction techniques, waste characterization, airborne contamination monitoring, engineering controls, worker protection, lessons learned, and waste minimization. Decontamination objectives are discussed in detail

  20. Elaboración y validación biomecánica de un guante de protección para jugar a pelota valenciana. (Elaboration and biomechanical validation of a protection glove for playing pelota valenciana.

    Directory of Open Access Journals (Sweden)

    Carlos Montaner-Sesmero

    2012-10-01

    ball obtained. According to this and the lack of a specific gear sport for the hand, it has been developed and tested a glove trying to solve those inconveniences. The glove was compared to a standard protection and were analyzed the hand pressures and the precision and distance achieved during the hit. Moreover the players’ opinion about the glove was registered using an inquiry. 15 players of pelota took part in the biomechanical test. The Biofoot/IBV® equipment adapted to the hand was used to record the hand pressures. The results show that the glove diminishes the pressure in three hand zones, offers the same precision and improves the hit distance than with the traditional protections. The players have successfully rated aspects such as the usability, the fit and thermal comfort. It has developed a glove that decreases the time of collocation in comparison to the traditional protections, gives better protection performance and in general is positively valued by the players.

  1. Activated Carbon Fibers with Hierarchical Nanostructure Derived from Waste Cotton Gloves as High-Performance Electrodes for Supercapacitors

    Science.gov (United States)

    Wei, Chao; Yu, Jianlin; Yang, Xiaoqing; Zhang, Guoqing

    2017-06-01

    One of the most challenging issues that restrict the biomass/waste-based nanocarbons in supercapacitor application is the poor structural inheritability during the activating process. Herein, we prepare a class of activated carbon fibers by carefully selecting waste cotton glove (CG) as the precursor, which mainly consists of cellulose fibers that can be transformed to carbon along with good inheritability of their fiber morphology upon activation. As prepared, the CG-based activated carbon fiber (CGACF) demonstrates a surface area of 1435 m2 g-1 contributed by micropores of 1.3 nm and small mesopores of 2.7 nm, while the fiber morphology can be well inherited from the CG with 3D interconnected frameworks created on the fiber surface. This hierarchically porous structure and well-retained fiber-like skeleton can simultaneously minimize the diffusion/transfer resistance of the electrolyte and electron, respectively, and maximize the surface area utilization for charge accumulation. Consequently, CGACF presents a higher specific capacitance of 218 F g-1 and an excellent high-rate performance as compared to commercial activated carbon.

  2. Activated Carbon Fibers with Hierarchical Nanostructure Derived from Waste Cotton Gloves as High-Performance Electrodes for Supercapacitors.

    Science.gov (United States)

    Wei, Chao; Yu, Jianlin; Yang, Xiaoqing; Zhang, Guoqing

    2017-12-01

    One of the most challenging issues that restrict the biomass/waste-based nanocarbons in supercapacitor application is the poor structural inheritability during the activating process. Herein, we prepare a class of activated carbon fibers by carefully selecting waste cotton glove (CG) as the precursor, which mainly consists of cellulose fibers that can be transformed to carbon along with good inheritability of their fiber morphology upon activation. As prepared, the CG-based activated carbon fiber (CGACF) demonstrates a surface area of 1435 m 2  g -1 contributed by micropores of 1.3 nm and small mesopores of 2.7 nm, while the fiber morphology can be well inherited from the CG with 3D interconnected frameworks created on the fiber surface. This hierarchically porous structure and well-retained fiber-like skeleton can simultaneously minimize the diffusion/transfer resistance of the electrolyte and electron, respectively, and maximize the surface area utilization for charge accumulation. Consequently, CGACF presents a higher specific capacitance of 218 F g -1 and an excellent high-rate performance as compared to commercial activated carbon.

  3. Gianotti-Crosti syndrome, pityriasis rosea, asymmetrical periflexural exanthem, unilateral mediothoracic exanthem, eruptive pseudoangiomatosis and papular-purpuric gloves and socks syndrome: a brief review and arguments for diagnostic criteria

    Directory of Open Access Journals (Sweden)

    Antonio Chuh

    2012-02-01

    Full Text Available Several exanthems including Gianotti-Crosti syndrome, pityriasis rosea, asymmetrical periflexural exanthem, eruptive pseudoangiomatosis, and papular-purpuric gloves and socks syndrome are suspected to be caused by viruses. These viruses are potentially dangerous. Gianotti-Crosti syndrome is related to hepatitis B virus infection which is the commonest cause of hepatocellular carcinoma, and Epstein-Barr virus infection which is related to nasopharyngeal carcinoma. Pityriasis rosea has been suspected to be related to human herpesvirus 7 and 8 infections, with the significance of the former still largely unknown, and the latter being a known cause of Kaposi’s sarcoma. Papular-purpuric gloves and socks syndrome is significantly associated with human B19 erythrovirus infection which can lead to aplastic anemia in individuals with congenital hemoglobinopathies, and when transmitted to pregnant women, can cause spontaneous abortions and congenital anomalies. With viral DNA sequence detection technologies, false positive results are common. We can no longer apply Koch’s postulates to establish causeeffect relationships. Biological properties of some viruses including lifelong latent infection, asymptomatic shedding, and endogenous reactivation render virological results on various body tissues difficult to interpret. We might not be able to confirm or refute viral causes for these rashes in the near future. Owing to the relatively small number of patients, virological and epidemiology studies, and treatment trials usually recruit few study and control subjects. This leads to low statistical powers and thus results have little clinical significance.

  4. Hepatitis E virus antibody prevalence in hunters from a district in Central Germany, 2013: a cross-sectional study providing evidence for the benefit of protective gloves during disembowelling of wild boars.

    Science.gov (United States)

    Schielke, A; Ibrahim, V; Czogiel, I; Faber, M; Schrader, C; Dremsek, P; Ulrich, R G; Johne, R

    2015-10-22

    In Germany, 17% of the general human population have antibodies to hepatitis E virus (HEV) (recomLine HEV-IgG/IgM immunoassay [Mikrogen GmbH]). Wild boars represent an animal reservoir for HEV genotype 3, which is the common genotype in Germany. We estimated the seroprevalence among hunters with contact to wild boars to identify factors that may be associated with past or present HEV infection. In 2013, the local veterinarian authority in a district in Central Germany attended meetings of hunters who provided blood specimens and completed a questionnaire collecting information on age, sex, hunting-related activities and consumption of wild boar meat. Specimens of wild boars were taken during drive hunts in this district during the season 2012/2013. All specimens were tested for HEV RNA and anti-HEV IgM and IgG antibodies. Log-binomial regression was used to estimate prevalence ratios (PR) for the hunters. Of 126 hunters (median age 55; 94% male) 21% tested positive for anti-HEV IgG antibodies (95% confidence interval [CI] 13-28%) (recomWell HEV IgG assay [Mikrogen GmbH]). Anti-HEV prevalence was highest in the age group of the 70-79-year-olds (67%; 95% CI 39-95%). Wild boars showed an average anti-HEV prevalence of 41%. HEV RNA was detected in 4/22 (18%) liver specimens and in 1/22 (4.5%) muscle specimens. Most wild boars were tested positive for HEV RNA (3/10; 30%) and HEV-specific antibodies (7/15; 47%) in the southwestern part of the district. Hunters preferring this hunting ground had a lower anti-HEV prevalence when gloves were frequently used during disembowelling of wild boars compared to hunters using gloves never or infrequently (age-adjusted PR 0.12; 95% CI 0.02-0.86). Hunters may benefit from wearing gloves when in contact with blood or body fluids of HEV animal reservoirs. Anti-HEV prevalence among the hunters of this study did not significantly differ from that of the general population suggesting that other factors play a major role in the

  5. User-Centric Feedback for the Development and Review of a Unique Robotic Glove Prototype to Be Used in Therapy

    Directory of Open Access Journals (Sweden)

    Stuart James Biggar

    2017-01-01

    Full Text Available Disability can be a great impediment to daily living in later life and is often the result of illness or trauma. Modern thoughts on treatment are orientated towards the use of robotics; however, these are often designed without consultation with the user. This paper used a 5-point questionnaire to ask former therapy patients what they felt needed further improvements from potential robotics and what features of such a system were the most important. Significant emphasis was placed on helping them to grasp (M = 4.63 as well as having a functional use. They also desired a system with clearly distinguished (M = 4.22 and easy to operate controls (M = 4.44 whilst allowing them some freedom to move around independently (M = 4.44. This provided the rationale for a prototype dual-layered vacuum glove that was sampled by healthcare staff to provide feedback that forms the basis for future improvements.

  6. Prevention of Cardiac Implantable Electronic Device Infections: Single Operator Technique with Use of Povidone-Iodine, Double Gloving, Meticulous Aseptic/Antiseptic Measures and Antibiotic Prophylaxis.

    Science.gov (United States)

    Manolis, Antonis S; Melita, Helen

    2017-01-01

    Cardiac implantable electronic device (CIED) implantation is complicated by infection still at a worrisome rate of 2-5%. Since early on during device implantation procedures, we have adopted an infection-preventive technique which has hitherto resulted in effective prevention of infections. Herein we present our results of applying this technique by a single operator in a prospective series of 762 consecutive patients undergoing device implantation. A meticulous search for and treatment of active, occult, or smoldering infection was undertaken preoperatively. An aseptic/antiseptic technique was used for implantation of each device. Skin preparation is thorough with initial cleansing performed with alcohol followed by povidone-iodine 10% solution, which is also used in the wound and inside the pocket. In addition, we routinely use double gloving, and IV antibiotic prophylaxis 1 hour before and for 48 hours afterwards followed by oral antibiotic for 2-3 days after discharge. The skin is closed with absorbable sutures. The study includes 382 patients having a new pacemaker (n = 333) or battery change, system upgrade or lead revision (n = 49), and 380 patients having a new implantable cardioverter-defibrillator (ICD) (n = 296) or device replacement/upgrade/lead revision (n = 84). The pacemaker group, aged 70.2 ± 16.5 years, includes 18% VVI, 49% DDD, 29% VDD, and 4% cardiac resynchronization therapy (CRT) devices. The ICD group, aged 61.3 ± 13.0 years, with a mean ejection fraction of 36 ± 13%, includes 325 ICD and 55 CRT implants. Over 26.6 ± 33.4 months for the pacemaker group and 36.6 ± 38.3 months for the ICD group, infection occurred in one patient in each group (0.26%) having a device replacement. A consistent and strict approach of aseptic/antiseptic technique with the use of double gloving and povidone-iodine solution within the pocket plus a 4-day regimen of antibiotic prophylaxis minimizes infections in CIED implants. © 2016 Wiley Periodicals, Inc.

  7. Metamodel-based design optimization of injection molding process variables and gates of an automotive glove box for enhancing its quality

    International Nuclear Information System (INIS)

    Kang, Gyung Ju; Park, Chang Hyun; Choi, Dong Hoon

    2016-01-01

    Injection molding process variables and gates of an automotive glove box were optimally determined to enhance its injection molding quality. We minimized warpage with satisfying constraints on clamp force, weldline, and profiles of filling and packing. Design variables concerning the injection molding process are temperatures of the mold and the resin, ram speeds, and packing pressures and durations; design variables concerning the gates are the shape of the center gate and locations of two side gates. To optimally determine the design variables in an efficient way, we adopted metamodel-based design optimization, sequentially using an optimal Latin hypercube design as a design of experiment, Kriging models as metamodels that replace time-consuming injection molding simulations, and a micro genetic algorithm as an optimization algorithm. In the optimization process, a commercial injection molding analysis software, MoldflowTM, was employed to evaluate the injection molding quality at design points specified. Using the proposed design approach, the warpage was found reduced by 20.5% compared to the initial warpage, while all the design constraints were satisfied, which clearly shows the validity of the proposed design approach

  8. Metamodel-based design optimization of injection molding process variables and gates of an automotive glove box for enhancing its quality

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Gyung Ju [Pusan National University, Busan (Korea, Republic of); Park, Chang Hyun; Choi, Dong Hoon [Hanyang University, Seoul (Korea, Republic of)

    2016-04-15

    Injection molding process variables and gates of an automotive glove box were optimally determined to enhance its injection molding quality. We minimized warpage with satisfying constraints on clamp force, weldline, and profiles of filling and packing. Design variables concerning the injection molding process are temperatures of the mold and the resin, ram speeds, and packing pressures and durations; design variables concerning the gates are the shape of the center gate and locations of two side gates. To optimally determine the design variables in an efficient way, we adopted metamodel-based design optimization, sequentially using an optimal Latin hypercube design as a design of experiment, Kriging models as metamodels that replace time-consuming injection molding simulations, and a micro genetic algorithm as an optimization algorithm. In the optimization process, a commercial injection molding analysis software, MoldflowTM, was employed to evaluate the injection molding quality at design points specified. Using the proposed design approach, the warpage was found reduced by 20.5% compared to the initial warpage, while all the design constraints were satisfied, which clearly shows the validity of the proposed design approach.

  9. Applying human factors and ergonomics to the misuse of nonsterile clinical gloves in acute care.

    Science.gov (United States)

    Wilson, Jennie; Bak, Aggie; Loveday, Heather P

    2017-07-01

    Health care workers (HCWs) are recommended to wear nonsterile clinical gloves (NSCG) for direct contact with blood and body fluids. However, there is evidence of extensive inappropriate NSCG use. A mixed-methods study comprising observation of NSCG use in 2 acute hospitals and semistructured HCW interviews. Qualitative data were categorized using thematic analysis. Findings were mapped to the Systems Engineering Initiative for Patient Safety model and used to develop a strategy for improving NSCG use. Two hundred seventy-eight procedures performed in 178 episodes of care involved the use of NSCG. NSCG were inappropriate for 59% of procedures (165 out of 278). Risk of cross-contamination occurred in 49% (87 out of 178) episodes. Twenty-six HCWs were interviewed; emotion and socialization were key factors influencing decisions to use NSCG. Data from observation and thematic analysis were mapped to 6 interacting components of the Systems Engineering Initiative for Patient Safety work system. Interventions targeting each component informed quality improvement strategies CONCLUSIONS: Despite intense promotion of hand hygiene as the key measure to protect patients from health care-associated infection, NSCG dominate routine clinical practice and potential cross-contamination occurs in 50% of care episodes. Such practice is associated with significant environmental and financial costs and adversely affects patient safety. The application of human factors and ergonomics to the complex drivers of inappropriate NSCG behavior may be more effective than conventional approaches of education and policy in achieving the goal of preventing health care-associated infection and improving patient safety. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  10. Analysis of temperature profile and electric field in natural rubber glove due to microwave heating: effects of waveguide position

    Science.gov (United States)

    Keangin, P.; Narumitbowonkul, U.; Rattanadecho, P.

    2018-01-01

    Natural rubber (NR) is the key raw material used in the manufacture of other products such as rubber band, tire and shoes. Recently, the NR is used in natural rubber glove ( NRG) manufacturing in the industrial and medical fields. This research aims to investigate the electromagnetic wave propagation and heat transfer in NRG due to heating with microwave energy within the microwave oven at a microwave frequency of 2.45 GHz. Three-dimensional model of NRG and microwave oven are considered in this work. The comparative effects of waveguide position on the electric field and temperature profile in NRG when subjected to microwave energy are discussed. The finite element method (FEM) is used to solve the transient Maxwell’s equation coupled with the transient heat transfer equation. The simulation results with computer programs are validated with experimental results. The placement of waveguides in three cases are left hand side of microwave oven, right hand side of microwave oven and left and right hand sides of microwave oven are investigated. The findings revealed that the placing the waveguide on the right side of the microwave oven gives the highest electric field and temperature profile. The values obtained provide an indication toward understanding the study of heat transfer in NRG during microwave heating in the industry.

  11. 40 CFR 156.212 - Personal protective equipment statements.

    Science.gov (United States)

    2010-07-01

    ... footwear Shoes Shoes Chemical-resistant gloves 2 Chemical-resistant gloves 2 Chemical-resistant gloves 2 No... and diluted solely with water for application, the glove statement shall specify: “waterproof gloves... specify: “waterproof gloves” instead of the statement in paragraph (f)(4) of this section. (4) Other...

  12. [Human parvovirus B19 infection which first presented with petechial hemorrhage, followed by papular-purpuric gloves and socks syndrome and erythema infectiosum].

    Science.gov (United States)

    Sato, Atsuo; Umezawa, Remi; Kurosawa, Rumiko; Kajigaya, Yasuhiko

    2002-11-01

    A case of human parvovirus B19 (B19) infection is reported. A 6-year-old previously healthy girl was admitted to our hospital complaining of slight fever and petechial hemorrhage on her neck, trunk and the proximal parts of extremities. On admission, the platelet count was within normal range (180 x 10(3)/microliter) but white blood cells and reticulocytes were moderately suppressed (2.4 x 10(3)/microliter and 1@1000, respectively). The purpura disappeared in a week and the blood cell counts fully recovered without any specific treatment. Detection of B19 DNA and anti-B19 IgM antibody in the serum on admission led to the final diagnosis. Since the cellular receptor for B19, the blood group P antigen, is expressed on vascular endothelial cells as well as erythroid progenitor cells, the purpura was considered to be the result of direct vascular injury. She was very unique as she subsequently exhibited papular-purpuric gloves and socks syndrome and erythema infectiosum during follow-up. This case may provide a new insight into the pathogenesis of cutaneous manifestations of B19 infection.

  13. El uso de guantes como factor protector contra picaduras de alacrán durante la pizca de maíz en el estado de Guerrero, México The use of gloves as protector factor against scorpion stings during corn picking in the state of Guerrero, Mexico

    Directory of Open Access Journals (Sweden)

    Ascencio Villegas-Arrizón

    2009-04-01

    Full Text Available OBJETIVO: Identificar factores asociados a la picadura de alacrán durante la recolección de maíz, entre campesinos del estado de Guerrero. MATERIAL Y MÉTODOS: Estudio transversal hecho en 2004, sobre picaduras de alacrán durante el ciclo agrícola 2003, con encuesta a hogares en 14 comunidades del estado de Guerrero, seleccionadas de forma aleatoria. Se obtuvieron frecuencias simples y análisis bivariado para identificar los factores asociados a la picadura de alacrán durante la pizca de maíz. Se estimó razón de momios para valorar la magnitud del efecto. RESULTADOS: La incidencia de picadura de alacrán fue de 15% (500/3 294 en 2003. El empleo de guantes se acompañó de menor riesgo de picaduras de alacrán en la mano (RM = 0.11; IC 95% 0.06-0.18. Usar sólo un guante podría evitar 133 picaduras por cada 1 000 campesinos que ahora no los utilizan. Los costos implicados por la picadura de alacrán sumaron 505.90 pesos (46 dólares estadounidenses. CONCLUSIONES: Es necesario promover el uso de guantes entre campesinos que viven en zonas con alta endemicidad de alacranes. Asimismo, extender la red de suministro de suero antialacrán a toda el área rural donde predominan especies muy tóxicas y orientar a los campesinos sobre la importancia de buscar atención oportuna en las unidades de salud.OBJECTIVE: Identify factors associated with scorpion stings among farm workers who pick corn in the Mexican state of Guerrero. MATERIAL AND METHODS: Cross-sectional survey in 14 randomly selected communities in the state of Guerrero.Simple frequencies were obtained and bivariate analysis was used to identify factors associated with scorpion stings while picking corn. Odds ratio was estimated to evaluate the magnitude of the effect. RESULTS: The incidence of scorpion stings was 15% (500/3 294 in 2003. Use of gloves was associated with a dramatic reduction in risk of scorpion stings to the hands (OR = 0.11; IC95% 0.06-0.18. Scorpion stings are a

  14. Study on preparation of ultrafine lead tungstate for radiation protection and γ-ray shielding of the gloves

    International Nuclear Information System (INIS)

    Du Licheng; He Ping; Zhou Yuanlin; Song Kaiping; Yang Kuihua

    2012-01-01

    Lead tungstate combines the radiation shielding properties of tungsten and lead, and it is quite distinctive to manufacture lead tungstate with ultra-fine granularity to enhance its capacity of radiation shielding. The grain size of lead tungstate has direct impact on the ability of its protection from radioactive materials. the smaller the grain size and more uniform dispersion of lead tungstate, the better protective ability it is going to be. In this paper, soft-template synthesis was introduced to prepare ultra-fine PbWO 4 . Rigorous experiment conditions are settled to ensure the access to obtain ultra-fine, homogeneous lead tungstate product, and it is better than other physical and chemical preparation methods. The surface-active agent for the soft template, with S-60 for the water system W/O microemulsion zone, was used to synthesize successfully ultra-fine PbWO 4 . It was shown that dispersing agent S-60 in the soft template method produced ultra-fine PbWO 4 with uniform granularity distribution. By using orthogonal experimental method, the best experimental conditions were obtained as follows: S-60 as surfactant dispersant with diluted 30 times concentration, solutions with pH9, 0.01 mol/L concentration of reactant, 1300 rpm of stirring speed and slowly adding drops of Na 2 WO 4 solution into Pb (Ac) 2 solution. Based on the optimal experimental conditions, the product of ultra-fine product for the anti-radiation protection filler has been made. The fine packing for the preparation of tungsten the gamma rays on the gloves is an average capacity of 5% or so. (authors)

  15. Analysis of sulfidic linkages formed in natural rubber latex medical gloves by using X-ray absorption near edge structure

    Science.gov (United States)

    Chankrachang, M.; Limphirat, W.; Yongyingsakthavorn, P.; Nontakaew, U.; Tohsan, A.

    2017-09-01

    A study of sulfidic linkages formed in natural rubber (NR) latex medical gloves by using X-ray Absorption Near Edge Structure (XANES) is presented in this paper. The NR latex compound was prepared by using prevulcanization method, that is, it was prevulcanized at room temperature for 24 hrs before utilization. After the 24 hrs of prevulcanization, the latex film samples were obtained by dipping process. The dipped films were subjected to vulcanize at 110°C for 5 to 25 min. It was observed that after the compound was prevulcanized for 24 hrs, polysulfidic linkages were mainly formed in the sample. It was however found that after curing at 110°C for 5-25 min, the polysulfidic linkages are tended to change into disulfide linkages. Especially, in the case of 25 minutes cured sample, disulfide linkages are found to be the main linkages. In term of tensile strength, it was observed that when cure time increased from 5 - 10 min, tensile strengths were also increased. But when the cure time of the film is 25 minutes, tensile strength was slightly dropped. The dropped of tensile strength when cure time is longer than 10 minutes can be ascribed to a degradation of polysulfidic and disulfidic linkages during curing. Therefore, by using XANES analysis, it was found to be very useful to understand the cure characteristic, thus it can be very helpful to optimize cure time and tensile properties of the product.

  16. A new methodology for the assessment of hand protection from ultraviolet exposure.

    Science.gov (United States)

    Khazova, M; O'Hagan, J B; Grainger, K J-L

    2006-01-01

    A number of industrial applications and public services involve occupational exposure to ultraviolet radiation (UVR) from a variety of lamps and lasers. The aim of this study was to develop a methodology for the assessment of the UV protection level for disposable gloves. Glove UV protection factor is defined as a time-scale increase in exposure permitted for the hand protected by a glove with respect to an unprotected hand. Our study showed that for all tested gloves a change in UVR attenuation with stretching is characteristic for the type of glove material and can be included as a scaling factor in the definition of UVR protection. Glove material has a bigger effect on UVR protection level than variations in the glove thickness or its colour. Examples of assessment of the 'worst case scenario' are compared with the protection level against a number of sources, together with the guidance on a simplified evaluation protocol. An application-specific assessment, illustrated for 'SmartWater' forensic examinations and biological trans-illuminators, demonstrates that some gloves provide inadequate protection against occupational UV exposure.

  17. Síndrome da Luva Púrpura: principais intervenções preventivas e terapêuticas de enfermagem Síndrome del Guante Púrpura: principales intervenciones preventivas y terapéuticas de enfermería Purple Glove Syndrome: main preventive and therapeutic nursing interventions

    Directory of Open Access Journals (Sweden)

    Denise Miyuki Kusahara

    2007-06-01

    Full Text Available A Síndrome da Luva Púrpura, complicação relacionada à administração de fenitoína por cateteres intravenosos periféricos, caracteriza-se pelo surgimento de lesões teciduais no local de administração do fármaco, que variam de flebite à necrose local, sendo possível se identificar, nos casos mais severos, evolução para a síndrome compartimental e suas graves conseqüências. Este estudo teve por finalidade descrever a Síndrome da Luva Púrpura e os principais cuidados preventivos e terapêuticos de enfermagem. Identificaram-se 15 publicações sobre a temática, das quais incluíram-se dez artigos. Desta forma foi possível verificar as características da síndrome, bem como propor as principais intervenções de enfermagem, tanto na prevenção quanto no cuidado.El Síndrome del guante púrpura, complicación relacionada a la administración de fenitoína por catéteres intravenosos periféricos, se caracteriza por el surgimiento de lesiones teciduales en el lugar de la administración del fármaco, que varían de flebitis a la necrosis local, siendo posible identificarse, en los casos más severos, evolución para el síndrome compartimental y sus graves consecuencias. Este estudio tiene por finalidad describir el Síndrome del guante Púrpura y los principales cuidados preventivos y terapéuticos de enfermería. Se identificaron 15 publicaciones sobre la temática, de las cuales se incluyeron diez artículos. Fue posible verificar las características del síndrome, así como proponer las principales intervenciones de enfermería, tanto en la prevención como en el cuidado.The Purple Glove Syndrome, complication related to the administration of phenytoin through peripheral intravenous catheters, is characterized for the development of injuries in the site of catheter placement. Injuries range from phlebitis to local necrosis, being possible to identify in most severe cases, the development of the compartmental syndrome and

  18. Hand protection from ultraviolet exposure

    International Nuclear Information System (INIS)

    Khazova, M.; O'Hagan, J.B.

    2006-01-01

    Full text of publication follows: A number of industrial applications and public services involve exposure to ultraviolet radiation (U.V.R.) from a variety of lamps and lasers, for example, in forensic examination, biological trans-illuminators, dentistry, laser material processing, microelectronics, etc. The proposed European Union Directive on Optical Radiation would place specific requirements on employers to provide adequate safety measures to reduce exposure to U.V.R., including gloves for hand protection. The selection of gloves should be based on a risk assessment and on the performance characteristics of the gloves for the task. However, current International and national standards do not describe evaluation procedures of disposable gloves for hand protection against non-ionising radiation. A methodology for assessment of the UV protection level for disposable gloves and a simple measurement protocol are proposed, based on a common approach with UV protection by clothing and sunscreens. Glove Ultraviolet Protection Factor is defined as a time-scale increase in exposure permitted for the hand protected by a glove with respect to an unprotected hand. However, the wide variety of U.V.R. sources and the real-life conditions of glove use (stretching and wetting the surface by liquids) bring substantial challenges to the assessment method. Our study of ∼ 50 samples of widely used disposable gloves made of different materials (nitrile, vinyl, latex and chloroprene) showed that for all tested gloves a change in U.V.R. attenuation with stretching is characteristic for the type of glove material and can be included as a scaling factor in the definition of U.V.R. protection. Glove material has a bigger effect on U.V.R. protection level than variations in the glove thickness or its colour. The following approaches are suggested to overcome the problem of variable U.V.R. sources: - Worst case scenario minimal protection level, most restrictive case - Application

  19. Hand protection from ultraviolet exposure

    Energy Technology Data Exchange (ETDEWEB)

    Khazova, M.; O' Hagan, J.B. [Health Protection Agency, Radiation Protection Division, Chilton, Did cot (United Kingdom)

    2006-07-01

    Full text of publication follows: A number of industrial applications and public services involve exposure to ultraviolet radiation (U.V.R.) from a variety of lamps and lasers, for example, in forensic examination, biological trans-illuminators, dentistry, laser material processing, microelectronics, etc. The proposed European Union Directive on Optical Radiation would place specific requirements on employers to provide adequate safety measures to reduce exposure to U.V.R., including gloves for hand protection. The selection of gloves should be based on a risk assessment and on the performance characteristics of the gloves for the task. However, current International and national standards do not describe evaluation procedures of disposable gloves for hand protection against non-ionising radiation. A methodology for assessment of the UV protection level for disposable gloves and a simple measurement protocol are proposed, based on a common approach with UV protection by clothing and sunscreens. Glove Ultraviolet Protection Factor is defined as a time-scale increase in exposure permitted for the hand protected by a glove with respect to an unprotected hand. However, the wide variety of U.V.R. sources and the real-life conditions of glove use (stretching and wetting the surface by liquids) bring substantial challenges to the assessment method. Our study of {approx} 50 samples of widely used disposable gloves made of different materials (nitrile, vinyl, latex and chloroprene) showed that for all tested gloves a change in U.V.R. attenuation with stretching is characteristic for the type of glove material and can be included as a scaling factor in the definition of U.V.R. protection. Glove material has a bigger effect on U.V.R. protection level than variations in the glove thickness or its colour. The following approaches are suggested to overcome the problem of variable U.V.R. sources: - Worst case scenario minimal protection level, most restrictive case - Application

  20. Tactical Level Commander and Staff Toolkit

    Science.gov (United States)

    2010-01-01

    triggered by high winds and water includes life preservers and other marine-specific safety gear, waterproof boots, and special handling equipment for...especially to the hands, back, knees, and shoulders. Personnel should wear leather gloves, safety goggles, and steel-toed shoes and avoid lifting more than...floodwaters, put on plastic or rubber gloves, boots, and other protective clothing. Double gloving with a waterproof glove under a heavy work