WorldWideScience

Sample records for glove box facility

  1. Glove boxes

    International Nuclear Information System (INIS)

    Eisert, G.A.

    1979-01-01

    An arrangement for effecting access for performing work within a glove box comprises an elongate arm-length impermeable flexible sleeve, a fitting having an aperture therethrough, adapted to be secured in sealing relation in a port, in a wall of the glove box, the fitting including an outwardly extending lip having at least one continuous groove extending around its outer periphery, one end of the sleeve extending through the aperture in fitting and being folded back against the outer periphery of the lip, a resilient fastening ring securing the sleeve in sealing engagement in the groove, clamping means securing the sleeves to the lip and a glove secured in sealing relation via a bushing to the other end of the sleeve. (author)

  2. Glove box

    International Nuclear Information System (INIS)

    Morita, Atsushi

    1990-01-01

    Wire rope earthquake proof supports having sufficient vibration transmitting and attenuating property are disposed between a fixed floor and the bottom of a glove box in order to improve earthquake proofness of the glove box. The vertical weight of the glove box is supported by support legs slidable on the surface of the fixed floor. The wire rope earthquake-proof supports when undergoing a load, cause stretching and rolling against the external force such as earthquakes, and provide flexible spring support and cause a great damping due to friction with strands. Further, the vertical weight is always supported by the support legs and, when a horizontal weight is applied, the glove box slides on the fixed floor freely with slidable members. In this way, stress concentration generated at joint portions of columns and beams can be moderated greatly and earthquake proofness can be improved. Further, quality control and maintenance for the device is almost unnecessary owing to excellent fatigue-resistant characteristics of the wire rope earthquake proof supports. (N.H.)

  3. An MCNP model of glove boxes in a plutonium processing facility

    International Nuclear Information System (INIS)

    Dooley, D.E.; Kornreich, D.E.

    1998-01-01

    Nuclear material processing usually occurs simultaneously in several glove boxes whose primary purpose is to contain radioactive materials and prevent inhalation or ingestion of radioactive materials by workers. A room in the plutonium facility at Los Alamos National Laboratory has been slated for installation of a glove box for storing plutonium metal in various shapes during processing. This storage glove box will be located in a room containing other glove boxes used daily by workers processing plutonium parts. An MCNP model of the room and glove boxes has been constructed to estimate the neutron flux at various locations in the room for two different locations of the storage glove box and to determine the effect of placing polyethylene shielding around the storage glove box. A neutron dose survey of the room with sources dispersed as during normal production operations was used as a benchmark to compare the neutron dose equivalent rates calculated by the MCNP model

  4. Removable glove for a glove box

    International Nuclear Information System (INIS)

    Lucas, J.M.

    1982-01-01

    The glove includes one part forming a cuff and another part forming the glove. These two parts are joined in a leak-tight manner by a rigid ring. The glove part is interchangeable without breaking the seal through two neighbouring grooves formed on the ring to receive a bead made on the open end of the glove. The grooves are visible when the glove is placed outside the glove box, thereby enabling the glove part to be changed in this position [fr

  5. Glove box shield

    Science.gov (United States)

    Brackenbush, L.W.; Hoenes, G.R.

    A shield for a glove box housing radioactive material is comprised of spaced apart clamping members which maintain three overlapping flaps in place therebetween. There is a central flap and two side flaps, the side flaps overlapping at the interior edges thereof and the central flap extending past the intersection of the side flaps in order to insure that the shield is always closed when the user wthdraws his hand from the glove box. Lead loaded neoprene rubber is the preferred material for the three flaps, the extent of lead loading depending upon the radiation levels within the glove box.

  6. Glove box posting system

    International Nuclear Information System (INIS)

    McIntosh, A.E.

    1981-01-01

    A system for posting objects into closed containers, such as glove boxes, is described in which the bag used, preferably made of plastic, does not have to be fitted and sealed by the operator during each posting operation. (U.K.)

  7. Decontamination of TRU glove boxes

    International Nuclear Information System (INIS)

    Crawford, J.H.

    1978-03-01

    Two glove boxes that had been used for work with transuranic nuclides (TRU) for about 12 years were decontaminated in a test program to collect data for developing a decontamination facility for large equipment highly contaminated with alpha emitters. A simple chemical technique consisting of a cycle of water flushes and alkaline permanganate and oxalic acid washes was used for both boxes. The test showed that glove boxes and similar equipment that are grossly contaminated with transuranic nuclides can be decontaminated to the current DIE nonretrievable disposal guide of <10 nCi TRU/g with a moderate amount of decontamination solution and manpower. Decontamination of the first box from an estimated 1.3 Ci to about 5 mCi (6 nCi/g) required 1.3 gallons of decontamination solution and 0.03 man-hour of work for each square foot of surface area. The second box was decontaminated from an estimated 3.4 Ci to about 2.8 mCi (4.2 nCi/g) using 0.9 gallon of decontamination solution and 0.02 man-hour for each square foot of surface area. Further reductions in contamination were achieved by repetitive decontamination cycles, but the effectiveness of the technique decreased sharply after the initial cycle

  8. Role of non-destructive examinations in leak testing of glove boxes for industrial scale plutonium handling at nuclear fuel fabrication facility along with case study

    International Nuclear Information System (INIS)

    Aher, Sachin

    2015-01-01

    Non Destructive Examinations has the prominent role at Nuclear Fuel Fabrication Facilities. Specifically NDE has contributed at utmost stratum in Leak Testing of Glove Boxes and qualifying them as a Class-I confinement for safe Plutonium handling at industrial scale. Advanced Fuel Fabrication Facility, BARC, Tarapur is engaged in fabrication of Plutonium based MOX (PuO 2 , DDUO 2 ) fuel with different enrichments for first core of PFBR reactor. Alpha- Leak Tight Glove Boxes along with HEPA Filters and dynamic ventilation form the promising engineering system for safe and reliable handling of plutonium bearing materials considering the radiotoxicity and risk associated with handling of plutonium. Leak Testing of Glove Boxes which involves the leak detection, leak rectification and leak quantifications is major challenging task. To accomplish this challenge, various Non Destructive Testing methods have assisted in promising way to achieve the stringent leak rate criterion for commissioning of Glove Box facilities for plutonium handling. This paper highlights the Role of various NDE techniques like Soap Solution Test, Argon Sniffer Test, Pressure Drop/Rise Test etc. in Glove Box Leak Testing along with procedure and methodology for effective rectification of leakage points. A Flow Chart consisting of Glove Box leak testing procedure starting from preliminary stage up to qualification stage along with a case study and observations are discussed in this paper. (author)

  9. Seismic stability of a standalone glove box structure

    International Nuclear Information System (INIS)

    Saraswat, A.; Reddy, G.R.; Ghosh, S.; Ghosh, A.K.; Kumar, Arun

    2014-01-01

    Highlights: • Glove box is a leak tight, safety related structure used for handling radiotoxic materials. • To study the seismic performance of a freestanding glove box, extensive shake table testing has been carried out. • Glove box maintained structural integrity and leak tightness up to design basis earthquake loading. • Detailed three-dimensional finite element model of the structure is developed and analyzed by using direct time integration methods. • Simplified numerical method is proposed and successfully applied, to quickly estimate sliding displacement and determine upper bounds for it. - Abstract: In a nuclear fuel cycle facility, radiotoxic materials are being handled in freestanding leak tight enclosures called glove boxes (GBs). These glove boxes act as a primary confinement for the radiotoxic materials. Glove boxes are designed as per codal requirements for class I component. They are designed to withstand extreme level of earthquake loading with a return period of 10,000 years. To evaluate seismic performance of the glove box, there is a need to check the stability (sliding and overturning), structural integrity (stresses and strains) and leak tightness under earthquake loading. Extensive shake table experiments were conducted on a single standalone glove box. Actual laboratory conditions were simulated during testing to check the response. After extensive shake table testing, glove box structure was also analyzed using finite element (FE) software. Detailed three-dimensional model of glove box structure was developed and analyzed using nonlinear time history method. It was observed that finite element methods could be utilized to accurately predict dynamic response of glove box structure. This paper discusses the details and results of shake table testing and methodology used for modelling and analysing freestanding glove box structure under seismic loading. In addition, simplified numerical procedure, developed using energy conservation

  10. Seismic stability of a standalone glove box structure

    Energy Technology Data Exchange (ETDEWEB)

    Saraswat, A., E-mail: anupams@barc.gov.in [Bhabha Atomic Research Centre, Mumbai (India); Reddy, G.R. [Bhabha Atomic Research Centre, Mumbai (India); Ghosh, S. [Indian Institute of Technology Bombay, Mumbai (India); Ghosh, A.K.; Kumar, Arun [Bhabha Atomic Research Centre, Mumbai (India)

    2014-09-15

    Highlights: • Glove box is a leak tight, safety related structure used for handling radiotoxic materials. • To study the seismic performance of a freestanding glove box, extensive shake table testing has been carried out. • Glove box maintained structural integrity and leak tightness up to design basis earthquake loading. • Detailed three-dimensional finite element model of the structure is developed and analyzed by using direct time integration methods. • Simplified numerical method is proposed and successfully applied, to quickly estimate sliding displacement and determine upper bounds for it. - Abstract: In a nuclear fuel cycle facility, radiotoxic materials are being handled in freestanding leak tight enclosures called glove boxes (GBs). These glove boxes act as a primary confinement for the radiotoxic materials. Glove boxes are designed as per codal requirements for class I component. They are designed to withstand extreme level of earthquake loading with a return period of 10,000 years. To evaluate seismic performance of the glove box, there is a need to check the stability (sliding and overturning), structural integrity (stresses and strains) and leak tightness under earthquake loading. Extensive shake table experiments were conducted on a single standalone glove box. Actual laboratory conditions were simulated during testing to check the response. After extensive shake table testing, glove box structure was also analyzed using finite element (FE) software. Detailed three-dimensional model of glove box structure was developed and analyzed using nonlinear time history method. It was observed that finite element methods could be utilized to accurately predict dynamic response of glove box structure. This paper discusses the details and results of shake table testing and methodology used for modelling and analysing freestanding glove box structure under seismic loading. In addition, simplified numerical procedure, developed using energy conservation

  11. Glove boxes and similar containments

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    According to the present invention a glove box or similar containment is provided with an exhaust system including a vortex amplifier venting into the system, the vortex amplifier also having its main inlet in fluid flow connection with the containment and a control inlet in fluid flow connection with the atmosphere outside the containment. (U.S.)

  12. Hot cells and glove boxes

    International Nuclear Information System (INIS)

    1992-05-01

    Hot cells and glove boxes have been designed and developed to conduct operations involving radioactive materials which require some degree of manipulation. Glove boxes were developed to manipulate alpha emitters. As their name indicates, these are airtight boxes usually constructed with transparent, see-through walls. Operations are conducted inside by means of gloves or mechanic manipulators. These boxes are also used for biological-protection purposes, e.g., manipulation of viruses or similar applications. Basically, hot cells are used for: - radioisotope fractionning and purification; - post-irradiation studies, and - tests or sundry operations involving radiological or biological protection. These shielded cells are constructed on a supporting structure made out of steel and antimonious Pb bricks with airtight inner enclosures and lead-glass windows. Operations are conducted by means of remote telemanipulators. Airtight enclosures are made out of a stainless steel structure forming an Omega-shaped profile on the openings which are fitted with acrylic panels. Tight-proof insulation is achieved by means of appropriate joints placed between the structure and acrylic plates. Electric passage ducts for fluids or electrical conductors also preserve absolute hermeticity. The partition enclosures are placed on supporting tables made out of normalized sections and steel plates. If needed, enclosures, may be removed and replaced by others. For materials-transference purposes, these cells are provided with shielded doors, air-tight doors and a connecting duct between the tight-proof enclosures with a guillotine-type gate and a pneumatic remote-control coupling/uncoupling system. Each work post is provided with an operations console and a control cabinet with depression indicating manometers, input inlet valves and electrical interconnecting boards. A desk-type console centralizes operation commands which will take place inside the enclosures. Appropriate lighting has been

  13. Electrical requirements for unshielded glove boxes

    International Nuclear Information System (INIS)

    1978-02-01

    The specification relates to the general design and installation of electrical services required in unshielded glove boxes in which atmospheres of air, argon or nitrogen etc. may exist either temporarily or permanently. The specification does not apply to electrical services for glove boxes with flammable explosive atmospheres. (author)

  14. Earthquake resistance test of full-scale glove box

    International Nuclear Information System (INIS)

    Fujita, T.; Ohtani, K.; Hayashi, M.; Kozeki, M.; Ide, T.; Sakuno, K.

    1989-01-01

    A glove box used at nuclear facilities must confine radioactive materials. High airtightness and negative internal pressure are used to prevent leaks. The allowable leakage rate of air is 0.1% vol/hr or less at the pre-service inspection. The negative pressure value is kept at - 30 mm H 2 O in normal operation. The glove box structural strength and its confinement reliability during an earthquake are major concerns. The verification of aseismic analysis methods and assumptions for a glove box are thus of great importance. Data on the dynamic behavior of giant glove boxes was recently obtained in large shaker experiments. This paper describes these experimental results and the appropriateness of aseismic analysis methods used in current design

  15. Confirmation test on confinement performance of improved glove box

    International Nuclear Information System (INIS)

    Miura, S.; Kanazawa, J.; Nakajima, M.; Sakuno, K.; Miyata, H.

    1995-01-01

    Glove boxes are used at nuclear facilities to confine radioactive materials by ensuring a high level of airtightness and negative internal pressure. The allowable rate of air leakage is 0.1% vol/hr or less at the pre-service inspection. The negative pressure value is normally maintained at about -30 mm H 2 O. Structural strength and confinement reliability of glove boxes during earthquake are major concerns, and most important glove boxes are designed to withstand seismic class A events is Japan. This paper describes vibration tests done to confirm that improve large-sized glove boxes maintain their confinement performance and structural strength even during earthquake and that the design analysis methods used are appropriate. (author). 1 ref., 6 figs., 3 tabs

  16. Glove boxes. Dimensions and requirements. Draft

    International Nuclear Information System (INIS)

    1985-07-01

    The standard is to be applied to work done in glove-boxes, whereby either the personnel need to be protected from the damaging effects of the materials being handled, or the materials from the effects of the environment. It is to be applied to glove-boxes in which substances are handled which emit ionising radiation (radioactive substances). This norm is not restricted to glove-boxes in which processes are carried out on a technique scale. In accordance with this norm, only those pressures and temperatures are allowed to be present in the glove-boxes, that do not offer significantly from the work areas. Alongside the stipulations of this standard regard is also always to be taken of the regulations in the radiation protection ordinance. (orig./HP) [de

  17. The Inhalation Toxicity of VX Aerosols Assessed in the McNamara Glove Box Facility

    National Research Council Canada - National Science Library

    Carpin, John C; McCaskey, David A; Cameron, Kenneth P

    2005-01-01

    ... in this facility and to serve as a benchmark for ranking the toxicity of other agents. Neat VX challenge aerosols were generated by feeding micro-liter quantities of agent from a loaded syringe to a custom-made air assist atomizer...

  18. Ballast system for maintaining constant pressure in a glove box

    Science.gov (United States)

    Shlichta, Paul J.

    1989-09-01

    A ballast system is disclosed for a glove box including a fixed platform on which is mounted an inflatable bag on top of which resides a cover and a weight. The variable gas volume of the inflatable bag communicates with that of the glove box via a valved tube. The weight and the gas volume are selected to maintain a relatively constant pressure in the glove box despite variations in the glove box volume while avoiding the use of complicated valving apparatus.

  19. Alpha contamination assessment for D ampersand D activities: Monitoring inside glove boxes and vessels

    International Nuclear Information System (INIS)

    Rawool-Sullivan, M.W.; Bolton, R.D.; Conaway, J.G.; MacArthur, D.W.

    1996-02-01

    We have developed a new approach to glove box monitoring that involves drawing air out of one glove port through a detection grid that collects ions created in the air inside the glove box by ionizing radiation, especially alpha radiation. The charge deposited on the detection grid by the ions is measured with a sensitive electrometer. The air can be circulated back to the glove box through the other glove port, preventing contamination from leaving the glove box and detector system. Initial experiments using a mock-up constructed of sheet metal indicate that this technology provides the measurement technique needed to perform a defensible, non-invasive measurement of alpha contamination inside glove boxes destined for waste disposal. This can result in an enormous cost savings if a given glove box can be shown to fall into the catagory of Low-Level Waste rather than Trans-Uranic Waste. Considering that hundreds of glove boxes contaminated with plutonium will be taken out of service at various nuclear facilities over the next few years, the potential cost savings associated with disposal as LLW rather than TRU waste are substantial

  20. Striking dynamics and kinetic properties of boxing and MMA gloves

    Directory of Open Access Journals (Sweden)

    Benjamin Lee

    2014-08-01

    Full Text Available With the growing popularity of Mixed Martial Arts (MMA as a competitive sport, questions regarding the dynamic response and properties of MMA gloves arise. High-energy impacts from punches are very similar to boxing yet MMA competition requires the use of 4 oz fingerless glove, compared to the larger full enclosure boxing glove. This work assessed the kinetic properties and strike dynamics of MMA gloves and compared findings with traditional boxing gloves. Gloves mounted on a molded fist were impacted repetitively on an instrumental anvil designed for impact, over a 5 hour period resulting in 10,000 continuous and consistent strikes. Kinetic data from impacts were sampled at the beginning of the data collection and subsequently every 30 minutes (every 1,000 strikes. MMA gloves produced 4-5 times greater peak force and 5 times faster load rate compared to the boxing glove. However, MMA gloves also showed signs of material fatigue, with peak force increasing by 35% and rate of loading increasing by 60% over the duration of the test. Boxing glove characteristics did deteriorate but to a lesser extent. In summary, the kinetic properties of MMA glove differed substantially from the boxing glove resulting in impacts characterized by higher peak forces and more rapid development of force. Material properties including stiffness and thickness play a role in the kinetic characteristics upon impact, and can be inferred to alter injury mechanisms of blunt force trauma.

  1. Decontamination and dismantling of large plutonium-contamined glove boxes

    International Nuclear Information System (INIS)

    Draulans, J.

    1991-01-01

    This report describes the work performed in the frame of two C.E.C. - Contracts FI1D-002400-B Decommissioning of very large glove boxes and FI1D-0058 Decommissioning of a complex glove box structure to be dismounted partially on place. Detailed information is given about each glove box. The selection of the solution Transportation of the glove boxes to a specialized dismantling plant is justified. The necessary contacts inside the BELGONUCLEAIRE MOX plant and between the latter and other organizations are explained. The problems of manipulating large gloves are listed and the retained solution of building a so called Stiffening frame around each glove box is described. Furthermore information is given concerning required operators time for cleaning, manipulating, packing and dismantling together with received doses and quantities of waste produced. Concerning the glove box unit partially to be dismounted on place, detailed information is given about the way the glove boxes have been treated prior to this partial dismantling on place and about the way this partial dismantling has been performed. From these results one can conclude that such a delicate task can be performed without major difficulties. Finally information is given of the decontamination test of a highly Pu contaminated glove box with freon with rather poor results and of the preliminary CO 2 blasting tests on non active samples

  2. Design innovation for the management of alpha contaminated unserviceable glove boxes

    International Nuclear Information System (INIS)

    Devendra Sandhanshive; Shivaji Shendge; SK Pol; KNS Nair; PK Wattal; IA Sarjekhan, Arun Kumar

    2013-01-01

    With the maturing of nuclear industry, there is an added burden on the Back End of fuel cycle. Radioactive facilities are in the need for refurbishment. This paper describes the steps adopted for managing such alpha contaminated unserviceable Glove Boxes. The first step consisted of in-situ encasement of individual Glove Boxes, encountering the challenges of low head room and space congestion in these laboratories with cognizance to regulatory requirement related to radiation safety. The second step was removal, transfer and placement of encased Glove Boxes in a dedicated facility under continuous surveillance. The glove boxes will remain stored in this facility until arrangements are completed for dismantling and volume reduction in another facility dedicated for this purpose. The final step is the development of an appropriate technique for dismantling/cutting of Glove Boxes in an alpha-tight facility constructed to prevent spread of airborne activity, collection of cut pieces, subsequent decontamination of these metallic wastes and disposal. The paper describes the design scheme for dismantling of the glove box. The description also includes hands on evaluation of tools and gadgets in pilot set-up with a view to incorporating the most credible choice in an upcoming active facility. (authors)

  3. A System for Cooling inside a Glove Box

    Science.gov (United States)

    Sanz, Martial

    2010-01-01

    An easy, efficient, reliable, and low-cost method of constructing a cooling system using a simple circulating pump is described. The system is employed in conjunction with an inert atmosphere glove box to achieve the synthesis of air- and moisture-sensitive compounds inside the glove box at controlled, low temperatures without contaminating the…

  4. Disconnection and transport from a controlled zone of a closed plutonium glove box

    International Nuclear Information System (INIS)

    Aparicio, G.; Insegna, M.A.; Mathot, S.R.; Munoz, C.; Orlando, O.S.; Salguero, D.; Toubes, B.

    1990-01-01

    The glove box, to be closed due to the damage caused after 12 operation years in the alpha facility, and following the pertinent vacuum operations and decontamination (described in a previous work 'Closure of an analytical chemistry glove box in alpha-laboratory') must be transported to a transitory storage located in a site inspected by the Development Branch supervised by the Licentiating Branch. (Author) [es

  5. Closure of an analytical chemistry glove box in alpha laboratory

    International Nuclear Information System (INIS)

    Adelfang, P.; Aparicio, G.; Cassaniti, P.

    1990-01-01

    The works with plutonium are performed in gloves box, operated below atmospheric pressure, to protect the experimenters from this alpha-active material. After 12 years of continual processes, it was necessary the decommissioning of the chemistry glove box in our alpha-laboratory. A great deal of our attention was devoted to the working techniques because of extreme care needed to avoid activity release. The decommissioning includes the following main operations: a) Planning and documentation for the regulatory authority. b) Internal decontamination with surface cleaning and chelating agents. c) Measurement of the remainder internal radioactivity. d) Sealing of the glove ports and nozzles. e) Disconnection of the glove box from the exhaust duct. f) Design and construction of a container for the glove box. g) Transportation of the glove box from alpha-laboratory, to a transitory storage until its final disposal. The above mentioned operations are described in this paper including too: data of personal doses during the operations, characteristics and volumes of radioactive wastes and a description of the instrument used for the measurement of inside glove box activity. (Author) [es

  6. COMPUTER MODEL AND SIMULATION OF A GLOVE BOX PROCESS

    International Nuclear Information System (INIS)

    Foster, C.

    2001-01-01

    The development of facilities to deal with the disposition of nuclear materials at an acceptable level of Occupational Radiation Exposure (ORE) is a significant issue facing the nuclear community. One solution is to minimize the worker's exposure though the use of automated systems. However, the adoption of automated systems for these tasks is hampered by the challenging requirements that these systems must meet in order to be cost effective solutions in the hazardous nuclear materials processing environment. Retrofitting current glove box technologies with automation systems represents potential near-term technology that can be applied to reduce worker ORE associated with work in nuclear materials processing facilities. Successful deployment of automation systems for these applications requires the development of testing and deployment strategies to ensure the highest level of safety and effectiveness. Historically, safety tests are conducted with glove box mock-ups around the finished design. This late detection of problems leads to expensive redesigns and costly deployment delays. With wide spread availability of computers and cost effective simulation software it is possible to discover and fix problems early in the design stages. Computer simulators can easily create a complete model of the system allowing a safe medium for testing potential failures and design shortcomings. The majority of design specification is now done on computer and moving that information to a model is relatively straightforward. With a complete model and results from a Failure Mode Effect Analysis (FMEA), redesigns can be worked early. Additional issues such as user accessibility, component replacement, and alignment problems can be tackled early in the virtual environment provided by computer simulation. In this case, a commercial simulation package is used to simulate a lathe process operation at the Los Alamos National Laboratory (LANL). The Lathe process operation is indicative of

  7. Fusion welded fabrication of unshielded steel glove boxes

    International Nuclear Information System (INIS)

    1981-04-01

    This Specification deals with the manufacture, testing, inspection and delivery of fabricated glove boxes, including such internal and/or external fittings as are shown on the relevant drawings. (author)

  8. Design of strong wooden box coated with fiberglass reinforced resin for shipping and burial of contaminated glove boxes. Final report

    International Nuclear Information System (INIS)

    1982-01-01

    The project scope of work included the complete decontamination and decommissioning (D and D) of the Westinghouse ARD Fuel Laboratories at the Cheswick Site in the shortest possible time. This has been accomplished in the following four phases: (1) preparation of documents and necessary paperwork; packaging and shipping of all special nuclear materials in an acceptable form to a reprocessing agency; (2) decontamination of all facilities, glove boxes and equipment; loading of generated waste into bins, barrels and strong wooden boxes; (3) shipping of al bins, barrels and boxes containing waste to the designated burial site; removal of all utility services from the laboratories; and (4) final survey of remaining facilities and certification for nonrestricted use; preparation of final report. This attachment contains design of strong wooden box coated with fiberglass reinforced resin for shipping and burial of contaminated glove boxes

  9. A sealed enclosure of the glove box type

    International Nuclear Information System (INIS)

    Moreels, Pierre.

    1974-01-01

    The invention relates to a sealed enclosure of the glove-box type. According to the invention, the box-frame comprises: angle-bars having a right-angled cross-section, sealing joints, tightening bars and fastening means [fr

  10. Indigenous development of a glove box for ICP-OES

    International Nuclear Information System (INIS)

    Khan, A.M.; Anwar, M.K.; Bangash, M.A.

    2011-01-01

    Chemical analysis involving nuclear materials are bound to be carried out in safety enclosures like glove box, fume hood etc. whereas chemical analysis which produce mist or vapors of these materials like Atomic absorption Spectrometry, Flame photometry and ICP-AE spectrometry etc. must be performed in a glove box with HEPA filters on exhaust. These instruments with glove box adaptation are rare and impossible to import for our country. An ICP-OES, model Integra-XL of GBC-Australia was purchased in 2008 for chemical analysis of similar materials. As usual it was manufactured to operate in open atmosphere. The required analytical work could not be done in open atmosphere due to active nature of the samples. Therefore modification and glove box (GB) adaptation was required. Although large in size yet difficult to adapt for GB, the instrument had to be modified to a large extent as only sample handling part of the instrument had to placed inside GB, leaving rest of the instrument available for later repair/maintenance work. Different options were considered for modification keeping in mind the isolation and negative pressure inside the GB and maintaining the integrity of the instrument. One of such option was finalized which involved shifting the optic tank etc. A no of isolation gadgets were designed and fabricated locally. This indigenization has saved some handsome amount of foreign exchange. (Author)

  11. Glove box adaptation, installation and commissioning of WD-XRF system for determination of PuO2 in MOX fuel samples

    International Nuclear Information System (INIS)

    Aher, Sachin; Pandey, Ashish; Khan, F.A.; Das, D.K.; Kumar, Surendra; Behere, P.G.; Mohd Afzal

    2015-01-01

    Glove Box facility forms the foremost important confinement system at nuclear fuel fabrication facility for handling of Plutonium based MOX fuels. Due to limited resources of Natural Uranium and maximum utilization of thorium, India has adopted 'Close Fuel Cycle Strategy' which involves use of Plutonium based fuels in Thermal and Fast reactors. Plutonium being radio toxic material with a higher biological half-life, Plutonium based fuel fabrication facility requires special techniques and confinement as a primary method for protection against spreading of powder contamination. Glove Box along with dynamic ventilation and HEPA Filters forms the preeminent facility for safe handling of plutonium based MOX fuels. Various equipment's, systems and instruments associated with MOX fuel production are need to be adapted inside the Glove Box with considerations of safety, ergonomics, accessibility for operations and maintenance, connections of various feed through like electrical connections, gas line supply etc. Quality Control plays the vital role in production of MOX fuels to ensure the finest quality of product to meet the defined specifications of MOX fuels. Presently AFFF is fabricating MOX fuel containing 21% and 28% PuO 2 along with DDUO 2 the first core of PFBR. Precise quantification of PuO 2 in MOX fuel pellets is necessary process control steps after batch preparation in Milling and Mixing operation. At AFFF, WD-XRF is one of the system used for determination of percentage of PuO 2 in MOX fuel batch. Glove Box adaptation of WD-XRF system along with 30 Tones Hydraulic press for sample preparation is being carried out in Type VI and Type IV Glove Boxes connected through transfer tunnel. Due to restrictions of space inside the Glove Box, a special mechanism is developed and installed for safe titling of WD-XRF system inside the Glove Box during the need of maintenance. These Glove Boxes are leak tested by various leak testing technique to meet the

  12. Object-oriented process dose modeling for glove-box operations

    International Nuclear Information System (INIS)

    Boerigter, S.T.; Fasel, J.H.; Kornreich, D.E.

    1999-01-01

    The Plutonium Facility at Los Alamos National Laboratory (LANL) supports several defense- and non-defense-related missions for the country by performing fabrication, surveillance, and research and development for materials and components that contain plutonium. Most operations occur in rooms with one or more arrays of glove boxes connected to each other via trolley glove boxes. Each room may contain glove boxes dedicated to several different operations or functions. Minimizing the effective dose equivalent (EDE) is a growing concern as a result of steadily allowable dose limits being imposed and a growing general awareness of safety in the workplace. In general, the authors discriminate three components of a worker's total EDE: the primary EDE, the secondary EDE, and background EDE. The immediate sources to which a worker is exposed provide the primary EDE. The secondary EDE results from operations and sources in the same vicinity or room as the worker. The background EDE results from all other sources of radiation, such as natural sources and sources outside of the room. A particular background source of interest is the nuclear materials vault. The distinction between sources inside and outside of a particular room is arbitrary with the underlying assumption that building walls and floors provide significant shielding to justify including sources in other rooms in the background category. An associated paper details the tool that they use to determine the primary and secondary EDEs for all processes of interest in a room containing glove boxes

  13. Taking into account seismic risk on glove boxes

    International Nuclear Information System (INIS)

    Ladurelle, Marie; Philipponneau, Yannick

    2005-01-01

    Built in 1981, the LEFCA is a Basic Nuclear Facility (BNF) in which experimental plutonium based fuels are produced and characterised in about a hundred Gloves Boxes (GB). Many safety rules are required, especially those concerning seismic risk. In order to prepare the December 2003 safety reconsideration, the following methodology has been proposed so that GB might resist the Safe Shutdown Earthquake. 1) The determination of a safety target: the GB static containment. 2) The realisation of an ''in situ'' assessment: the definition of several classes of GB, vibrating table tests and the modelling of the GB behaviour with seismic solicitations, 3) A strength diagnosis for equipment: filters, connecting tunnels and pipes holding. 4) A proposal for further strengthening modifications if necessary : fixing the frame, interlocking GB and the frame, taking internal or external GB missiles into account. This process has contributed to a reduction in the radiological potential seismic impact for the neighbouring populations. We shall present the implemented methodology and the strengthening works that have been approved by Safety Authorities. Reinforcement modifications will begin in 2004. (Author)

  14. Application of glove box robotics to hazardous waste management

    International Nuclear Information System (INIS)

    Dennison, D.K.; Hurd, R.L.; Merrill, R.D.; Reitz, T.C.

    1995-02-01

    Lawrence Livermore Laboratory (LLNL) is developing a semi-automated system for handling, characterizing, processing, sorting, and repackaging hazardous wastes containing tritium. The system combines an IBM developed gantry robot with a special glove box enclosure designed to protect the operators and minimize the potential release of tritium to the atmosphere. All hazardous waste handling and processing will be performed remotely using the robot in a telerobotic mode for one-of-a-kind functions and in an autonomous mode for repetitive type operations. The system will initially be used in conjunction with a portable gas system designed to capture any gaseous phase tritium released into the glove box. This paper presents the objectives of this program, provides background related to LLNL's robotics and waste handling program, describes the major system components, outlines system operation, and discusses current status and plans

  15. Study of plutonium fire extinction in glove-boxes

    International Nuclear Information System (INIS)

    Boisson, H.; Chappellier, A.; Debiar, A.; Savornin, J.

    1965-01-01

    The report concerns attempts to extinguish fire in uranium - chosen as a basis for comparison - and in plutonium, these being contained in glove boxes. The extinguishing powders TEC and MG 10 were tried and compared. The operator used in plastic bags. The metal was dealt with respectively in the form of billets, compact chips and finally thin shavings. In each case fire control was without difficulty. One must allow a certain time for cooling. The powder MG 10 showed very good results. Moreover, the trials proved that densely packed shavings are a very real security factor. The interior lay-out of the glove boxes ought, in order to facilitate further manipulations, be such as to render extinction as easy as possible should the need arise. (authors) [fr

  16. Decontamination experiment of metals and floors of glove box

    International Nuclear Information System (INIS)

    Sun Yu; Li Ye; Tan Zhaoyi; Wang Ping; Wen Wei; Qiu Yongmei

    2010-01-01

    The wiping decontamination and stripping coating decontamination were applied to decontaminate the floors and metals in the glove box polluted by tritium. The results show that the polluting level is lower than 20 Bq/cm 2 through wiping decontamination. The DFs are higher for decontaminating higher-polluted metals using two stripping coatings while the polluted-level is lower than 20 Bq/cm 2 for decontaminating lower-polluted metals. (authors)

  17. Measuring Pu in a glove box using portable NaI and germanium detectors

    International Nuclear Information System (INIS)

    Hankins, D.E.

    1984-01-01

    A NaI crystal or germanium detector inside a portable lead shield can determine the amount of plutonium in a glove box. The number of counts required are defined and the locations outside the box where the detector needs to be positioned are given. The calculated accuracy for measuring the Pu when these locations are used is within +/-30% for most glove boxes. Other factors that may affect this accuracy, such as γ-ray absorption by glove-box materials, self-absorption by Pu, absorption by equipment in the glove box, and the limits of the counting equipment are also discussed

  18. Tritium stripping in a nitrogen glove box using palladium/zeolite and SAES St 198 trademark

    International Nuclear Information System (INIS)

    Klien, J.E.; Wermer, J.R.

    1995-01-01

    Glove box clean-up experiments were conducted in a nitrogen glove box using palladium deposited on zeolite (Pd/z) and a SAES St 198 trademark getter as tritium stripping materials. Protium/deuterium samples spiked with tritium were released into a 620 liter glove box to simulate tritium releases in a 10,500 liter glove box. The Pd/z and the SAES St 198 trademark stripper beds produced a reduction in tritium activity of approximately two to three orders of magnitude and glove box clean-up was limited by a persistent background tritium activity level. Attempts to significantly reduce the glove box activity to lower levels without purging were unsuccessful

  19. Decontamination and reconditioning of the Argonne National Laboratory-West Casting Laboratory alpha glove box

    International Nuclear Information System (INIS)

    Poston, J.W. Jr.; Burke, L.L.

    1998-01-01

    The Casting Laboratory (CL) alpha glove box was used to melt and cast metallic uranium and plutonium fuels as part of the Department of Energy''s Liquid Metal Fast Breeder Reactor Program. This highly contaminated alpha glove box was decontaminated and reconditioned to allow a change in mission. The goal of reconditioning was to install experimental apparatus and to improve contamination control prior to introducing plutonium-238 into the CL glove box. Construction of a glove box containment structure and an increase in room ventilation were required. A temporary breathing air station was provided for personnel protection as well as personnel comfort. The historical contamination levels, the decontamination techniques, and the results of decontamination also are presented. The health physics aspects of the CL alpha glove box project may be applicable to other glove box refurbishment or decommissioning projects

  20. Glovebox glove deterioration in the Hanford Engineering Development Laboratory fuel fabrication facility

    International Nuclear Information System (INIS)

    Greenhalgh, W.O.; Smith, R.C.; Powell, D.L.

    1979-07-01

    Neoprene glovebox gloves have been found susceptible to periodic rapid deterioration under normal operating conditions in fuel fabrication facilities. Examinations of glove failure histories and measurements of the atmospheres in inert atmosphere dry-boxes indicated ozone at low concentrations of 100 to 500 ppB was probably the most important factor in rapid glove deterioration. Testing of a varity of new glove materials indicated that Hypalon and ethylene-propylene-diamine monomer (EDPM) gloves have greater than 30 times the longevity of neoprene in low-level ozone concentration atmospheres. comparative tests over a 30-month period have also confirmed that the two glove candidates have a significantly longer operative life. 14 figures

  1. SEM modification and shielded glove box design for the radioactive material observation

    International Nuclear Information System (INIS)

    Seo, Ki-Seog; Ku, Jeong-Hoe; Bang, Kyoung-Sik; Lee, Ju-Chan; You, Gil-Sung; Ku, Dae-Seo; Min, Duck-Kee

    1999-01-01

    The Scanning Electron Microscope(SEM) installation in the shielded glove box was performed for the first time at KAERI early in 1999. The SEM was modified for handling the radioactive materials. The shielded glove box will be used for SEM operation as well as storing and coating the specimen. This paper describes the SEM installation in the shielded glove box and the first experiences of the surface analysis of the radioactive materials. (author)

  2. Glove box adaptation, installation and commissioning of an assembled modular type atomic absorption unit with GF atomizer

    International Nuclear Information System (INIS)

    Gupta, Santosh Kumar; Thulasidas, S.K.; Goyal, Neelam; Godbole, S.V.

    2013-09-01

    The report describes glove box adaptation of an in-house developed AAS unit with GF as atomization source for determination of trace metallic elements in Pu bearing samples. In order to replace the old Varian Techtron GF-AAS which was utilized for analysis of Pu bearing samples for the last thirty seven years, and as of late was giving too many practical problems, a new GF-AAS was designed and reassembled. The original compact flame AAS unit available with M/s. Thermo Fisher India Pvt. Ltd, Nashik, was converted into separated modular unit viz. Hollow Cathode Lamp unit, Atomizer unit and Monochromator - Detector - Readout unit. In addition, these modular units were modified with respect to their dimensions so as to enable their use with existing glove box facility developed earlier in 1980 for glove box incorporation. These units were separated from each other at their factory site so as to enable us to incorporate atomizer unit alone in the glove box. Glove box adapted GF-AAS is essential for Radiochemistry Division to provide analytical services to Chemical Quality Control of Pu bearing nuclear and related materials and also as an analytical support to the R and D activities of the Radiochemistry Division, BARC. (author)

  3. Source term analysis for a criticality accident in metal production line glove boxes

    International Nuclear Information System (INIS)

    Nguyen, D.H.

    1991-06-01

    A recent development in criticality accident analysis is the deterministic calculations of the transport of fission products and actinides through the barriers of the physical facility. The knowledge of the redistribution of the materials inside the facility will help determine the reentry and clean-up procedures. The amount of radioactive materials released to the environment is the source term for dispersion calculations. We have used an integrated computer model to determine the release of fission products to the environment from a hypothetical criticality event in a glove box of the metal production line (MPL) at the Lawrence Livermore National Laboratory (LLNL)

  4. Dismantling of alpha contaminated obsolete installations and glove boxes on the IRMM site in Geel (Belgium)

    International Nuclear Information System (INIS)

    Cretskens, Pieter; Lenie, Koen; Melis, Gustaaf

    2007-01-01

    At the Institute for Reference Materials and Measurements (European commission, Joint Research Centre, IRMM) a dismantling campaign of obsolete installations and glove boxes has been carried out in 2005. There were various reasons for their removal. Some large installations did not meet modern safety standards, other installations were worn out and expected to cause a radioactive contamination risk in the future. The main goal was to create as less waste as possible by extensive contamination checks and by decontamination if necessary. For the glove boxes, decontamination was not possible. A controlled area was set up around the installation to be dismantled in order to prevent spreading of contamination from dust and dirt. This was only possible for the 'minor' contaminated installations. The dismantling campaign of the glove boxes was carried out by using tents of two types depending the contamination inside the glove boxes. The most common glove boxes were dismantled in a tent constructed with hard surfaced polycarbonate plates (ventilated cell). For glove boxes with higher contamination, the same principle was used but with a second 'glove box tent' inside (ventilated glove tent). The purpose of this project was to learn from the experience of this campaign which gave the ability to make estimates of future radioactive waste or classic waste that could be expected from dismantled installations. (authors)

  5. Investigation on processing technology for tritiated water in glove box

    International Nuclear Information System (INIS)

    Luo Deli; Meng Daqiao

    2002-01-01

    A 0.5 nm molecular sieve absorption column and a hot decomposing magnesium bed was found to be one of the effective means to collect and decompose HTO in glove box atmosphere. The absorption characteristics of the 0.5 nm molecular sieve column and water decomposing characteristics of the hot Mg bed were obtained. The results showed that the column absorbs water vapour from air with efficiency up to 99.99%. Water in tested gases was between 3.4 x 10 3 to 4.2 x 10 3 μg·g -1 and the total water absorbed on the column was up to 162 g, under this condition no water was detected in output gases. Using the hot magnesium bed more than 99.9% desorption water from the column was decomposed

  6. Evaluation of decontamination during dismantling of plutonium-contaminated glove boxes

    International Nuclear Information System (INIS)

    Kinugasa, Manabu; Taguchi, Seigi; Ohzeki, Satoru; Inoue, Yoshiaki; Kashima, Sadamitsu

    1981-01-01

    The dismantling work of plutonium-contaminated glove boxes was carried out. These glove boxes had been used for the R and D of plutonium-uranium mixed oxide fuel for 15 years. The work was carried out in a pressure-controlled greenhouse, and the contamination of air in the greenhouse was monitored continuously. In order to reduce the contamination of air during dismantling, the decontamination and fixation of loose contaminants on the surfaces of glove boxes were very important. The correlation between decontamination and the contamination of air regarding dismantling is reported in this paper. The surface contamination density of the glove boxes was measured utilizing the smear method before and after the decontamination, and the decontamination effects were estimated. The contamination of air during dismantling was continuously measured with a plutonium dust monitor. It was found that loose contamination exponentially decreased by the decontamination process. When the so-called wet glove boxes, which contained wet recovery and waste disposal apparatus, were dismantled, the contamination of air did not exceed 500 (MPC) a. However, the contamination of air exceeded 500 (MPC) a several times in the present work of dismantling the so-called dry glove boxes which had been used for the fabrication of plutonium-uranium mixed oxide pellets. (Kato, T.)

  7. Determining Nuclear Fingerprints: Glove Boxes, Radiation Protection, and the International Atomic Energy Agency.

    Science.gov (United States)

    Rentetzi, Maria

    2017-06-01

    In a nuclear laboratory, a glove box is a windowed, sealed container equipped with two flexible gloves that allow the user to manipulate nuclear materials from the outside in an ostensibly safe environment. As a routine laboratory device, it invites neglect from historians and storytellers of science. Yet, since especially the Gulf War, glove boxes have put the interdependence of science, diplomacy, and politics into clear relief. Standing at the intersection of history of science and international history, technological materials and devices such as the glove box can provide penetrating insight into the role of international diplomatic organizations to the global circulation and control of scientific knowledge. The focus here is on the International Atomic Energy Agency. Copyright © 2017 The Author. Published by Elsevier Ltd.. All rights reserved.

  8. Holdup measurements of plutonium in glove box exhausts

    International Nuclear Information System (INIS)

    Glick, J.B.; Haas, F.X.; McKamy, J.N.; Garrett, A.G.

    1991-01-01

    A new measurement technique has been developed to quantify plutonium in process glove box exhausts. The technique implemented at Rocky Flats Plant utiltizes a shielded, collimated 0.5in. x 0.5in. bismuth germanate (BGO) gamma-ray detector. Pairs of measurements are made at one foot intervals along the duct. One measurement is made with the detector viewing the bottom of the duct with the detector crystal approximately 2 inches from the duct surface. The second measurement is made on the top of the exhaust pipe with the detector crystal 2 inches from the top of the duct. When the detector is placed in the bottom assay position, the area of the holdup material is assumed to extend beyond the detector field of view. The concentration of plutonium in g/cm 2 is obtained from this bottom measurement. The deposit width is determined from a model developed to relate the deposit width to the ratio of the count rates measured at the two positions, above and below the duct. Once a deposit width has been calculated, it is multiplied by the concentration determined from the bottom measurement to yield a mass- per-unit-length at the duct location. Total plutonium mass is then determined by multiplying the duct length by the average of the mass- per-unit length assays performed along the duct. The applicability of the technique is presented in a comparison of field measurement data to analysis results on material removed from the ducts. 3 refs., 3 figs., 1 tab

  9. Design, construction and mounting of a container for transportation and storage of a closed plutonium glove box

    International Nuclear Information System (INIS)

    Aparicio, G.; Insegna, M.A.; Mathot, S.R.; Munoz, C.; Orlando, O.S.; Salguero, D.

    1990-01-01

    With the aim of confining a closed chemistry glove box (with reference to papers: 'Closure of an analytical chemistry glove box in alpha Laboratory' and 'Disconnection and transportation of a closed plutonium glove box to a controlled zone'), it was necessary to design and construct a container to assure transportation from its location (a controlled zone) up to a definitive storage place capable of supporting its posterior confinement. (Author) [es

  10. Development of combined absolute and activated charcoal filters and glove box activated charcoal filter

    International Nuclear Information System (INIS)

    Khan, A.A.; Ramarathinam, K.; Deshingkar, D.S.; Kishore, A.G.

    1975-01-01

    Because of low maximum permissible concentration in air, airborne radioiodine must be removed from exhaust of nuclear facilities. Activated charcoal filters for glove-boxes and combined absolute and activated charcoal filters are currently being imported. In this work, activated charcoal filters of various types were developed using original as well as impregnated indigenous activated charcoals. These filters were evaluated for their iodine and methyl iodide removal efficiencies and pressure drop characteristics. The filters developed showed 99.9 + % removal efficiency both for iodine and methyl iodide. The pressure drop of the combined absolute and activated charcoal filters was even less than that of imported filters of this type. These filters can effectively substitute imported filters. (author)

  11. Low cost transportable device for transference of atmosphere sensitive materials from glove box to SEM

    DEFF Research Database (Denmark)

    Bentzen, Janet Jonna; Saxild, Finn B.

    the field of high energy battery research involving highly reactive metals, e.g. lithium, we needed a means of transferring atmosphere sensitive materials from the protective atmosphere of a glove box, avoiding air exposure, to a sample chamber of a scanning electron microscope. Thus, we constructed a low...... cost transportable device. The transportable transfer device holding a small evacuable chamber was constructed from a valve fitted with adapters to a glove box and a scanning electron microscope (JEOL 840). Examples of the application to high energy battery research are illustrated....

  12. Decontamination and size reduction of plutonium contaminated process exhaust ductwork and glove boxes

    International Nuclear Information System (INIS)

    LaFrate, P.; Elliott, J.; Valasquez, M.

    1996-01-01

    The Los Alamos National Laboratory (LANL) Decommissioning Program has decontaminated and demolished two filter plenum buildings at Technical Area 21 (TA-21). During the project a former hot cell was retrofitted to perform decontamination and size reduction of highly Pu contaminated process exhaust (1,100 ft) and gloveboxes. Pu-238/239 concentrations were as high a 1 Ci per linear foot and averaged approximately 1 mCi/ft. The Project decontamination objective was to reduce the plutonium contamination on surfaces below transuranic levels. If possible, metal surfaces were decontaminated further to meet Science and Ecology Group (SEG) waste classification guidelines to enable the metal to be recycled at their facility in oak Ridge, Tennessee. Project surface contamination acceptance criteria for low-level radioactive waste (LLRW), transuranic waste, and SEG waste acceptance criteria will be presented. Ninety percent of all radioactive waste for the project was characterized as LLRW. Twenty percent of this material was shipped to SEG. Process exhaust and glove boxes were brought to the project decontamination area, an old hot cell in Building 4 North. This paper focuses on process exhaust and glovebox decontamination methodology, size reduction techniques, waste characterization, airborne contamination monitoring, engineering controls, worker protection, lessons learned, and waste minimization. Decontamination objectives are discussed in detail

  13. Adaptation of a glow discharge mass spectrometer in a glove-box for the analysis of nuclear materials

    International Nuclear Information System (INIS)

    Betti, M.; Rasmussen, G.; Hiernaut, T.; Koch, L.

    1994-01-01

    A VG9000 glow discharge mass spectrometer has been modified for the direct analysis of solid nuclear samples within a glove-box environment. Because containment is needed for the analysis of this kind of material, the glove-box encloses all parts of the instrument that come into contact with the sample, namely the ion source chamber, sample interlock and associated pumping system. External modifications eliminate outside contamination by the fitting of absolute filters on all source supplies. Internally the design of the ion source has been altered to minimize the number of operations performed inside the glove-box thereby simplifying operation and routine maintenance. These modifications retain the ion extraction and focusing properties of the instrument. The data presented show that there is no compromise in the analytical performance of the instrument when placed in the glove-box. Data representative of nuclear materials is also shown. (Author)

  14. Handling of a glove box accident. Surgical treatment of a wound contaminated by a mixture of plutonium-239 and americium

    International Nuclear Information System (INIS)

    Lalu, P.

    1977-01-01

    An employee of the Valduc Centre (France) suffered an injury to his right thumb when working in a glove-box on a pipeline which had contained a solution of 239 Pu and Am. The lesion was slight but attempts at decontamination were fruitless. The contamination was deep-seated (activity of not less than 18nCi). DTPA was injected intravenously, and it was decided to excise the lesion surgically. Thanks to the quality of its physical facilities and the professional quality of its radiation medicine and surgery team, the Valduc Centre was able to carry out the operation successfully. The result was excellent, and the contamination was eliminated to the satisfaction of both the patient and the physician. (author)

  15. Handling and analysis of ices in cryostats and glove boxes in view of cometary samples

    International Nuclear Information System (INIS)

    Roessler, K.; Eich, G.; Heyl, M.; Kochan, H.; Oehler, A.; Patnaik, A.; Schlosser, W.; Schulz, R.

    1989-01-01

    Comet nucleus sample return mission and other return missions from planets and satellites need equipment for handling and analysis of icy samples at low temperatures under vacuum or protective gas. Two methods are reported which were developed for analysis of small icy samples and which are modified for larger samples in cometary matter simulation experiments (KOSI). A conventional optical cryostat system was modified to allow for transport of samples at 5 K, ion beam irradiation, and measurement in an off-line optical spectrophotometer. The new system consists of a removable window plug containing nozzles for condensation of water and volatiles onto a cold finger. This plug can be removed in a vacuum system, changed against another plug (e.g., with other windows (IR, VIS, VUV) or other nozzles). While open, the samples can be treated under vacuum with cooling by manipulators (cut, removal, sample taking, irradiation with light, photons, or ions). After bringing the plug back, the samples can be moved to another site of analysis. For handling the 30 cm diameter mineral-ice samples from the KOSI experiments an 80x80x80 cm glove box made out of plexiglass was used. The samples were kept in a liquid nitrogen bath, which was filled from the outside. A stream a dry N 2 and evaporating gas from the bath purified the glove box from impurity gases and, in particular, H 2 O, which otherwise would condense onto the samples

  16. Operating manual for the electrostatic glove-box prefilter installed inside the filter glove box No. 046 at Rocky Flats, Building 776

    International Nuclear Information System (INIS)

    Bergman, W.; Kaifer, R.C.; Hebard, H.D.; Taylor, R.D.; Lum, B.Y.; Boling, R.M.; Buttedahl, O.I.; Woodard, R.W.; Terada, K.

    1979-01-01

    Objective of the evaluation is to evaluate the effectiveness of the electrostatic prefilter in prolonging the life of HEPA (high-efficiency particulate-air) filters. The theory of the electrostatic filter is reviewed, and Glove Box Number 046 is described in detail, followed by a description of the electrostatic prefilter used in the present application. Engineering drawings of the electrostatic prefilter are included. The procedure for evaluating the electrostatic prefilter includes the steps for conducting five different tests: evaluating (1) the HEPA filter alone, (2 and 3) the HEPA filter with a standard prefilter treated both as disposable and reusable, and (4 and 5) the HEPA filter with the electrostatic prefilter, again treated as disposable and reusable. Procedures for flowmeter calibrations and measurements of particle-size distributions are also included. Long-term maintenence of the system during the evaluation program is outlined, and estimates of component durability are given. An electrical engineering safety note describes the high-voltage operational hazard of the electrostatic prefilter and the testing of safety devices

  17. Robotic and nuclear safety for an automated/teleoperated glove box system

    International Nuclear Information System (INIS)

    Domning, E.E.; McMahon, T.T.; Sievers, R.H.

    1991-09-01

    Lawrence Livermore National Laboratory (LLNL) is developing a fully automated system to handle the processing of special nuclear materials (SNM). This work is performed in response to the new goals at the Department of Energy (DOE) for hazardous waste minimization and radiation dose reduction. This fully automated system, called the automated test bed (ATB), consists of an IBM gantry robot and automated processing equipment sealed within a glove box. While the ATB is a cold system, we are designing it as a prototype of the future hot system. We recognized that identification and application of safety requirements early in the design phase will lead to timely installation and approval of the hot system. This paper identifies these safety issues as well as the general safety requirements necessary for the safe operation of the ATB. 4 refs., 2 figs

  18. Distributed Nd-YAG laser welding and process control in inert glove boxes

    International Nuclear Information System (INIS)

    Milewski, J.O.; Lewis, G.K.; Barbe, M.R.; Cremers, D.A.

    1993-01-01

    We have fabricated and assembled a fiber optic delivered ND-YAG laser welding work station that consists of three glove boxes served by a single 1kw laser. Processing considerations related to the welding of special nuclear materials, toxic materials and complex part geometry are addressed within each work cell. We are proceeding with a development effort to integrate the equipment capabilities with remote sensing, process monitoring and control systems. These systems will provide real time data acquisition during welding, monitoring and verification of weld parameters, and CAD/CAM to CNC generated positioning paths. Computerized information storage, retrieval and network methods are used for weld process documentation and data analysis. A virtual control panel is being configured to integrate the monitoring and control operation of individual subsystems, such as laser and motion control into a single graphical interface. Development work on sensors to monitor laser beam characteristics and weld depth in real time with potential for adaptive control is in progress. System capabilities and results of these development efforts are presented

  19. Handwashing and glove use in a long-term-care facility.

    Science.gov (United States)

    Thompson, B L; Dwyer, D M; Ussery, X T; Denman, S; Vacek, P; Schwartz, B

    1997-02-01

    To determine glove use and handwashing practices, the factors associated with infection control practices, and the frequency of potential microbial transmission in a long-term-care facility (LTCF). Observational study of 230 staff-resident interactions in an LTCF. We recorded resident characteristics, type of activity, staff credentials, and movements of the staff member's hands, then used the LTCF's guidelines to judge appropriateness of glove use and handwashing. 255-bed, university-based LTCF in Baltimore, Maryland. A systematic sample of staff-resident interactions. Gloves were worn in 139 (82%) of 170 interactions when indicated, but changed appropriately in only 1 (16%) of 132. Hands were washed when needed before an interaction in 27%, during an interaction in 0%, and after an interaction in 63%. Gloves were less likely to be used when caring for residents with gastrostomy tubes compared with other residents (relative risk, 0.85; 95% confidence interval, 0.73-0.98). Guidelines were followed more frequently during wound care than during other activities. Microbial transmission potentially could have occurred in 158 (82%) of 193 evaluable interactions. We documented marked deficiencies in glove and handwashing, demonstrated the possible impact of these deficiencies, and identified factors associated with inadequate handwashing and glove use. This information can be used in future educational and research efforts to improve infection control practices.

  20. Los Alamos Transuranic Waste Size Reduction Facility

    International Nuclear Information System (INIS)

    Harper, J.; Warren, J.

    1987-06-01

    The Los Alamos Transuranic (TRU) Waste Size Reduction Facility (SRF) is a production oriented prototype. The facility is operated to remotely cut and repackage TRU contaminated metallic wastes (e.g., glove boxes, ducting and pipes) for eventual disposal at the Waste Isolation Pilot Plant (WIPP) near Carlsbad, New Mexico. The resulting flat sections are packaged into a tested Department of Transportation Type 7A metal container. To date, the facility has successfully processed stainless steel glove boxes (with and without lead shielding construction) and retention tanks. We have found that used glove boxes generate more cutting fumes than do unused glove boxes or metal plates - possibly due to deeply embedded chemical residues from years of service. Water used as a secondary fluid with the plasma arc cutting system significantly reduces visible fume generation during the cutting of used glove boxes and lead-lined glove boxes. 2 figs., 1 tab

  1. Los Alamos Transuranic Waste Size Reduction Facility

    International Nuclear Information System (INIS)

    Harper, J.; Warren, J.

    1987-01-01

    The Los Alamos Transuranic (TRU) Waste Size Reduction Facility (SRF) is a production oriented prototype completed in 1981 and later modified during 1986 to enhance production. The facility is operated to remotely cut (with a plasma arc torch) and repackage TRU contaminated metallic wastes (e.g., glove boxes, ducting and pipes) for eventual disposal at the Waste Isolation Pilot Plant (WIPP) near Carlsbad, New Mexico. The resulting flat sections are packaged into a tested Department of Transportation Type 7A metal container. To date, the facility has successfully processed stainless steel glove boxes (with and without lead shielding construction) and retention tanks. It was found that used glove boxes generate more cutting fumes than do unused glove boxes or metal plates - possibly due to deeply embedded chemical residues from years of service. Water used as a secondary fluid with the plasma arc cutting system significantly reduces visible fume generation during the cutting of used glove boxes and lead-lined glove boxes

  2. Inductively coupled plasma -- Atomic emission spectroscopy glove box assembly system at the West Valley Demonstration Project

    Energy Technology Data Exchange (ETDEWEB)

    Marlow, J.H.; McCarthy, K.M.; Tamul, N.R.

    1999-12-17

    The inductively coupled plasma/atomic emission spectroscopy [ICP/AES (ICP)] system for elemental analyses in support of vitrification processing was first installed in 1986. The initial instrument was a Jobin Yvon (JY) Model JY-70 ICP that consisted of sequential and simultaneous spectrometers for analysis of nonradioactive samples as radioactive surrogates. The JY-70 ICP continued supporting nonradioactive testing during the Functional and Checkout Testing of Systems (FACTS) using the full-scale melter with ``cold'' (nonradioactive) testing campaigns. As a result, the need for another system was identified to allow for the analysis of radioactive samples. The Mass Spec (Spectrometry) Lab was established for the installation of the modified ICP system for handling radioactive samples. The conceptual setup of another ICP was predicated on the use of a hood to allow ease of accessibility of the torch, nebulizer, and spray chamber, and the minimization of air flow paths. However, reconsideration of the radioactive sample dose rate and contamination levels led to the configuration of the glovebox system with a common transfer interface box for the ICP and the inductively coupled plasma-mass spectrometer (ICP-MS) glovebox assemblies. As a result, a simultaneous Model JY-50P ICP with glovebox was installed in 1990 as a first generation ICP glovebox system. This was one of the first ICP glovebox assemblies connected with an ICP-MS glovebox system. Since the economics of processing high-level radioactive waste (HLW) required the availability of an instrument to operate 24 hours a day throughout the year without any downtime, a second generation ICP glovebox assembly was designed, manufactured, and installed in 1995 using a Model JY-46P ICP. These two ICP glovebox systems continue to support vitrification of the HLW into canisters for storage. The ICP systems have been instrumental in monitoring vitrification batch processing. To date, remote sample preparation

  3. Plutonium metal burning facility

    International Nuclear Information System (INIS)

    Hausburg, D.E.; Leebl, R.G.

    1977-01-01

    A glove-box facility was designed to convert plutonium skull metal or unburned oxide to an oxide acceptable for plutonium recovery and purification. A discussion of the operation, safety aspects, and electrical schematics are included

  4. Determining the Radiation Damage Effect on Glovebox Glove Material.

    Energy Technology Data Exchange (ETDEWEB)

    Cournoyer, M. E. (Michael E.); Balkey, J. J. (James J.); Andrade, R.M. (Rose M.)

    2005-01-01

    The Nuclear Material Technology (NMT) Division has the largest inventory of glove box gloves at Los Alamos National Laboratory. The minimization of unplanned breaches in the glovebox, e.g., glove failures, is a primary concern in the daily operations in NMT Division facilities, including the Plutonium Facility (PF-4) at TA-55 and Chemical and Metallurgy Research (CMR) Facility. Glovebox gloves in these facilities are exposed to elevated temperatures and exceptionally aggressive radiation environments (particulate {sup 239}Pu and {sup 238}Pu). Predictive models are needed to estimate glovebox glove service lifetimes, i.e. change-out intervals. Towards this aim aging studies have been initiated that correlate changes in mechanical (physical) properties with degradation chemistry. This present work derives glovebox glove change intervals based on previously reported mechanical data of thermally aged hypalon glove samples. Specifications for 30 mil tri-layered hypalon/lead glovebox gloves (TLH) and 15 mil hypalon gloves (HYP) have already been established. The relevant mechanical properties are shown on Table 1. Tensile strength is defined as the maximum load applied in breaking a tensile test piece divided by the original cross-sectional area of the test piece (Also termed maximum stress and ultimate tensile stress). Ultimate elongation is the elongation at time of rupture (Also termed maximum strain). The specification for the tensile test and ultimate elongation are the minimum acceptable values. In addition, the ultimate elongation must not vary 20% from the original value. In order to establish a service lifetimes for glovebox gloves in a thermal environment, the mechanical properties of glovebox glove materials were studied.

  5. Glove box chamber

    International Nuclear Information System (INIS)

    Cox, M.E.; Cox, M.E.

    1975-01-01

    An environmental chamber is described which enables an operator's hands to have direct access within the chamber without compromising a special atmosphere within such chamber. A pair of sleeves of a flexible material are sealed to the chamber around associated access apertures and project outwardly from such chamber. Each aperture is closed by a door which is openable from within the sleeve associated therewith so that upon an operator inserting his hand and arm through the sleeve, the operator can open the door to have access to the interior of the chamber. A container which is selectively separable from the remainder of the chamber is also provided to allow objects to be transferred from the chamber without such objects having to pass through the ambient atmosphere. An antechamber permitting objects to be passed directly into the chamber from the ambient atmosphere is included. (auth)

  6. Interim report on the activity hold-up and ease of decontamination of permanent coatings and surface treatments incorporated in a glove box floor

    International Nuclear Information System (INIS)

    Dalton, J.T.; Eccles, E.W.; Sutcliffe, P.W.; Turner, A.D.; Dawson, R.K.

    1987-12-01

    A commercial GRP glove box has been equipped with 1 square foot tiles of alternative flooring materials. These comprise highly polished GRP, PEEK, electropolished stainless steel, cold-rolled stainless steel foil, bright nickel electroplate on stainless steel and hard chrome electroplate on stainless steel. The natural GRP finish was used as a reference surface. Standard PuO 2 handling and floor abrasion operations have been carried out on a regular basis. Subsequently, the floor tiles have been decontaminated by swabbing with Arklone soaked tissues and a mass balance has determined the fraction of PuO 2 unaccounted to be about 1%. Hard, smooth surfaces are promising to give the best performance in minimising activity retention under these abrasive conditions to ∼ 100 μg cm -2 . Glove box aerosol concentrations have also been monitored as a function of time after the completion of handling operations by air sampling and by gravity settling. After an initial rapid decrease over ∼ 2 hours, a steady state is reached corresponding to ∼ 1 ng/l of PuO 2 . (author)

  7. Interim report on the activity hold-up, and ease of decontamination of permanent coatings and surface treatments incorporated in a glove box floor

    International Nuclear Information System (INIS)

    Dalton, J.T.; Eccles, E.W.; Sutcliffe, P.W.; Turner, A.D.; Dawson, R.K.

    1987-11-01

    A commercial glass reinforced plastic (GRP) glove box has been equipped with 1 square foot tiles of alternative flooring materials. These comprise highly polished GRP, poly-ether-ether-ketone (PEEK), electropolished stainless steel, cold-rolled stainless steel foil, bright nickel electroplate on stainless steel and hard chrome electroplate on stainless steel. The natural GRP finish was used as a reference surface. Standard PuO 2 handling and floor abrasion operations have been carried out on a regular basis. Subsequently, the floor tiles have been decontaminated by swabbing with Arklone soaked tissues and a mass balance has determined the fraction of PuO 2 unaccounted to be about 1%. Hard, smooth surfaces are promising to give the best performance in minimizing activity retention under these abrasive conditions to ∼ 100 μg cm -2 . Glove box aerosol concentrations have also been monitored as a function of time after the completion of handling operations by air sampling and by gravity settling. After an initial rapid decrease over ∼ 2 hours, a steady state is reached corresponding to ∼ 1 ng/l of PuO 2 . (author)

  8. Optical Fier Based System for Multiple Thermophysical Properties for Glove Box, Hot Cell and In-Pile Application

    Energy Technology Data Exchange (ETDEWEB)

    Ban, Heng

    2017-11-30

    Thermal diffusivity of materials is of interest in nuclear applications at temperatures in excess of 2000°C. Commercial laser flash apparatus (LFA) that heats samples with a furnace typically do not reach these elevated temperatures nor are they easily adapted to a glove-box or hot cell environment. In this research, we performed work on an experimental technique using single laser surface heating, i.e. heating the disk sample only at its front surface with the continuous wave (CW) laser, to allow measurement of thermal diffusivity at very high temperatures within a small chamber. Thermal diffusivity is measured using a separate pulsed laser on the front side and IR detector on the rear side. The new way of heating provides easy operation in comparison to other heating methods. The measurement of sample reference temperature is needed for the measured thermal diffusivity. A theoretical model was developed to describe transient heat transfer across the sample due to the laser pulse, starting from the steady state temperature of the sample heated by the CW laser. The experimental setup was established with a 500W CW laser and maximum 50 Joule pulse laser irradiated at the front surface of the sample. The induced temperature rise at the rear surface, along with the steady-state temperature at the front surface, was recorded for the determination of thermal diffusivity and the sample temperature. Three samples were tested in vacuum over a wide temperature range of 500°C to 2100°C, including graphite, Inconel 600 and tungsten. The latter two samples were coated with sprayed graphite on their front surfaces in order to achieve surface absorption/emission needs, i.e. high absorptivity of the front surface against relatively low emissivity of the rear surface. Thermal diffusivity of graphite determined by our system are within a 5% difference of the commercial LFA data at temperatures below 1300°C and agree well with its trend at higher temperatures. Good agreement

  9. Metamodel-based design optimization of injection molding process variables and gates of an automotive glove box for enhancing its quality

    International Nuclear Information System (INIS)

    Kang, Gyung Ju; Park, Chang Hyun; Choi, Dong Hoon

    2016-01-01

    Injection molding process variables and gates of an automotive glove box were optimally determined to enhance its injection molding quality. We minimized warpage with satisfying constraints on clamp force, weldline, and profiles of filling and packing. Design variables concerning the injection molding process are temperatures of the mold and the resin, ram speeds, and packing pressures and durations; design variables concerning the gates are the shape of the center gate and locations of two side gates. To optimally determine the design variables in an efficient way, we adopted metamodel-based design optimization, sequentially using an optimal Latin hypercube design as a design of experiment, Kriging models as metamodels that replace time-consuming injection molding simulations, and a micro genetic algorithm as an optimization algorithm. In the optimization process, a commercial injection molding analysis software, MoldflowTM, was employed to evaluate the injection molding quality at design points specified. Using the proposed design approach, the warpage was found reduced by 20.5% compared to the initial warpage, while all the design constraints were satisfied, which clearly shows the validity of the proposed design approach

  10. EVA Glove Sensor Feasbility II Abstract

    Science.gov (United States)

    Melone, Kate

    2014-01-01

    The main objectives for the glove project include taking various measurements from human subjects during and after they perform different tasks in the glove box, acquiring data from these tests and determining the accuracy of these results, interpreting and analyzing this data, and using the data to better understand how hand injuries are caused during EVAs.1 Some of these measurements include force readings, temperature readings, and micro-circulatory blood flow.1 The three glove conditions tested were ungloved (a comfort glove was worn to house the sensors), Series 4000, and Phase VI. The general approach/procedure for the glove sensor feasibility project is as follows: 1. Prepare test subject for testing. This includes attaching numerous sensors (approximately 50) to the test subject, wiring, and weaving the sensors and wires in the glove which helps to keep everything together. This also includes recording baseline moisture data using the Vapometer and MoistSense. 2. Pressurizing the glove box. Once the glove box is pressurized to the desired pressure (4.3 psid), testing can begin. 3. Testing. The test subject will perform a series of tests, some of which include pinching a load cell, making a fist, pushing down on a force plate, and picking up metal pegs, rotating them 90 degrees, and placing them back in the peg board. 4. Post glove box testing data collection. After the data is collected from inside the glove box, the Vapometer and MoistSense device will be used to collect moisture data from the subject's hand. 5. Survey. At the conclusion of testing, he/she will complete a survey that asks questions pertaining to comfort/discomfort levels of the glove, glove sizing, as well as offering any additional feedback.

  11. Gloves Reprocessing: Does It Really Save Money?

    OpenAIRE

    Arora, Pankaj; Kumari, Santosh; Sodhi, Jitender; Talati, Shweta; Gupta, Anil Kumar

    2015-01-01

    Gloves are reprocessed and reused in health-care facilities in resource-limited settings to reduce the cost of availability of gloves. The study was done with the aim to compute the cost of reprocessing of gloves so that an economically rationale decision can be taken. A retrospective record-based cross-sectional study was undertaken in a central sterile supply department where different steps during reprocessing of gloves were identified and the cost involved in reprocessing per pair of glov...

  12. Wearing gloves in the hospital

    Science.gov (United States)

    Infection control - wearing gloves; Patient safety - wearing gloves; Personal protective equipment - wearing gloves; PPE - wearing gloves; Nosocomial infection - wearing gloves; Hospital acquired infection - ...

  13. Seismic evaluation of the LLNL plutonium facility (Building 332)

    International Nuclear Information System (INIS)

    Hall, W.J.; Sozen, M.A.

    1982-03-01

    The expected performance of the Lawrence Livermore National Laboratory (LLNL) Plutonium Facility (Building 332) subjected to earthquake ground motion has been evaluated. Anticipated behavior of the building, glove boxes, ventilation system and other systems critical for containment of plutonium is described for three severe postulated earthquake excitations. Based upon this evaluation, some damage to the building, glove boxes and ventilation system would be expected but no collapse of any structure is anticipated as a result of the postulated earthquake ground motions

  14. Improved Emission Spectrographic Facility

    International Nuclear Information System (INIS)

    Goergen, C.R.; Lethco, A.J.; Hosken, G.B.; Geckeler, D.R.

    1980-10-01

    The Savannah River Plant's original Emission Spectrographic Laboratory for radioactive samples had been in operation for 25 years. Due to the deteriorated condition and the fire hazard posed by the wooden glove box trains, a project to update the facility was funded. The new laboratory improved efficiency of operation and incorporated numerous safety and contamination control features

  15. Gloves Reprocessing: Does It Really Save Money?

    Science.gov (United States)

    Arora, Pankaj; Kumari, Santosh; Sodhi, Jitender; Talati, Shweta; Gupta, Anil Kumar

    2015-12-01

    Gloves are reprocessed and reused in health-care facilities in resource-limited settings to reduce the cost of availability of gloves. The study was done with the aim to compute the cost of reprocessing of gloves so that an economically rationale decision can be taken. A retrospective record-based cross-sectional study was undertaken in a central sterile supply department where different steps during reprocessing of gloves were identified and the cost involved in reprocessing per pair of gloves was calculated. The cost of material and manpower was calculated to arrive at the cost of reprocessing per pair of gloves. The cost of a reprocessed pair of surgical gloves was calculated to be Indian Rupee (INR) 14.33 which was greater than the cost of a new pair of disposable surgical gloves (INR 9.90) as the cost of sterilization of one pair of gloves itself came out to  be INR 10.97. The current study showed that the purchase of sterile disposable single-use gloves is cheaper than the process of recycling. Reprocessing of gloves is not economical on tangible terms even in resource-limited settings, and from the perspective of better infection control as well as health-care worker safety, it further justifies the use of disposable gloves.

  16. Latex medical gloves

    DEFF Research Database (Denmark)

    Palosuo, Timo; Antoniadou, Irini; Gottrup, Finn

    2011-01-01

    properties of NRL and synthetic gloves and the role of glove powder. The review shows that NRL medical gloves, when compared with synthetic gloves, tend to be stronger, more flexible and better accepted by clinicians. The introduction of powder-free gloves has been associated with reductions in protein...

  17. Comprehension Strategy Gloves.

    Science.gov (United States)

    Newman, Gayle

    2002-01-01

    Describes the idea of creating a glove for each of the comprehension strategies for use with different text structures. Notes that the gloves serve as a multisensory approach by providing visual clues through icons on each finger and the palm. Discusses three different gloves: the prereading glove, the narrative text structure glove, and the…

  18. Contained scanning electron microscope facility for examining radioactive materials

    International Nuclear Information System (INIS)

    Hsu, C.W.

    1986-03-01

    At the Savannah River Laboratory (SRL) radioactive solids are characterized with a scanning electron microscope (SEM) contained in a glove box. The system includes a research-grade Cambridge S-250 SEM, a Tracor Northern TN-5500 x-ray and image analyzer, and a Microspec wavelength-dispersive x-ray analyzer. The containment facility has a glove box train for mounting and coating samples, and for housing the SEM column, x-ray detectors, and vacuum pumps. The control consoles of the instruments are located outside the glove boxes. This facility has been actively used since October 1983 for high alpha-activity materials such as plutonium metal and plutonium oxide powders. Radioactive defense waste glasses and contaminated equipment have also been examined. During this period the facility had no safety-related incidents, and personnel radiation exposures were maintained at less than 100 mrems

  19. Rubber glove wearing device

    International Nuclear Information System (INIS)

    Nozaki, Tatsuo; Takada, Kaoru.

    1994-01-01

    Rubber groves are attached each to an upper end of a glove putting vessel having an air-sucking hole on the bottom by enlarging an opening end of the rubber glove and turning back the inside to the outside. When the sucking device is operated, air in the glove putting device is sucked and the rubber glove is expanded by an atmospheric pressure. After expansion of the rubber glove to some extent, the sucking device is stopped, and presence or absence of failures of the rubber glove is confirmed by shrinkage of the rubber glove and by an indication value of a pressure gauge for detecting the pressure change in the vessel. Then, a hand is inserted to the expanded rubber glove, and a detaching switch in the vessel is pushed by a finger tip. A detaching piece at the upper end of the vessel is protruded outwardly to enlarge the turned-back portion of the rubber glove to easily release the rubber glove from the putting vessel, and the rubber glove is put on. This enables to wear the rubber glove and conduct failure test simultaneously. Further, a user can put on the rubber glove without touching the outside of the rubber glove. (I.N.)

  20. Commissioning and Testing of a new 4.5K Cold Box for JLab Cryogenic Test Facility

    Science.gov (United States)

    Wijeratne, T.; Hasan, N.; Wright, M.; Ganni, V.; Dixon, K.; Creel, J.; Knudsen, P.

    2017-12-01

    A new 4.5K cold box at Jefferson Lab (JLab) Cryogenic Test Facility (CTF) was recently installed and commissioned to upgrade the existing 4.5 K refrigeration system and work in parallel with the existing 4.5 K cold box. This new 4.5 K cold box is equipped with two turbo-expanders and, at its maximum capacity condition, it is expected to support at least 6.6 g/s of helium liquefaction or 650 W of refrigeration at 4.5 K. It can also handle up to 10 g/s 30 K return flow for 2 K refrigeration recovery that supports cryo-module and superconducting cavity testing. Performances of the cold box at its maximum capacity conditions as well as several other operating modes were tested for acceptance. We will briefly review the new 4.5 K cold box design features and discuss the commissioning and performance testing results.

  1. Decommissioning of the Risoe Hot Cell facility

    International Nuclear Information System (INIS)

    Carlsen, H.

    1991-08-01

    Concise descriptions of actions taken in relation to the decommissioning of the hot cell facility at Risoe National Laboratory are presented. The removal of fissile material, removal and decontamination of large cell internals, and of large equipment such as glove boxes and steel boxes, in addition to dose commitments, are explained. Tables illustrating the analysis of smear tests, constants for contamination level examination, contamination and radiation levels after cleaning and total contamination versus measured radiation are included. (AB)

  2. Anti-vibration gloves?

    Science.gov (United States)

    Hewitt, Sue; Dong, Ren G; Welcome, Daniel E; McDowell, Thomas W

    2015-03-01

    For exposure to hand-transmitted vibration (HTV), personal protective equipment is sold in the form of anti-vibration (AV) gloves, but it remains unclear how much these gloves actually reduce vibration exposure or prevent the development of hand-arm vibration syndrome in the workplace. This commentary describes some of the issues that surround the classification of AV gloves, the assessment of their effectiveness and their applicability in the workplace. The available information shows that AV gloves are unreliable as devices for controlling HTV exposures. Other means of vibration control, such as using alternative production techniques, low-vibration machinery, routine preventative maintenance regimes, and controlling exposure durations are far more likely to deliver effective vibration reductions and should be implemented. Furthermore, AV gloves may introduce some adverse effects such as increasing grip force and reducing manual dexterity. Therefore, one should balance the benefits of AV gloves and their potential adverse effects if their use is considered. © Crown copyright 2014.

  3. Glove use among hairdressers

    DEFF Research Database (Denmark)

    Oreskov, Katia W; Søsted, Heidi; Johansen, Jeanne D

    2015-01-01

    BACKGROUND: Hand eczema is frequent among Danish hairdressers, and they are advised to use gloves as protection. However, studies indicate that a significant proportion use gloves inappropriately. OBJECTIVES: To determine whether hairdressers and apprentices use protective gloves in the correct way......, and to determine whether a demonstration of correct use could cause an improvement. METHODS: Forty-three hairdressers and apprentices were asked to perform a hair wash while wearing gloves. The shampoo used was contaminated with an ultraviolet (UV) trace material. Two rounds of hair washing were carried out...... by each person, interrupted by a demonstration of how to use gloves correctly. Photographs were taken to compare UV contamination before and after the demonstration. RESULTS: All of the participants (100%) had their hands contaminated during the first round; the area ranged between 0.02 and 101.37 cm(2...

  4. Replacement of lead-loaded glovebox glove with attenuation medium that are not RCRA-hazardous metals

    Energy Technology Data Exchange (ETDEWEB)

    Cournoyer, Michael E [Los Alamos National Laboratory; George, Gerald L [Los Alamos National Laboratory; Dodge, Robert L [Los Alamos National Laboratory; Chunglo, Steve [CANBERRA INDUSTRIES

    2010-01-01

    Programmatic operations at the Los Alamos National Laboratory Plutonium Facility (TA-55) involve working with various amounts of plutonium and other highly toxic, alpha-emitting materials. The spread of radiological contamination on surfaces, airborne contamination, and excursions of contaminants into the operator's breathing zone are prevented through the use of a variety of gloveboxes (the glovebox, coupled with an adequate negative pressure gradient, provides primary confinement). Radiation shielding is commonly used to protect the glovebox worker from unintentional direct and secondary radiation exposure, while working with plutonium-238 and plutonium-239. In these environments, low-energy photons, i.e., those less than 250 keY, are encountered. Shielding glove box gloves are traditionally composed of lead-based materials, but these are now considered hazardous waste. This has prompted the development of new, nonhazardous- shielding gJovebox gloves. No studies, however, have investigated the effectiveness of these new glovebox gloves. We examined both leaded and nonhazardous- shielding glovebox gloves and compared their attenuation effectiveness over the energy range of interest at TA-55. All measurements are referenced to lead sheets, allowing direct comparisons to the common industry standard of 0.1 mm lead equivalent material. The attenuation properties of both types of glovebox gloves vary with energy, making it difficult for manufacturers to claim lead equivalency across the entire energy range used at TA-55. The positions of materials' photon energy absorption edges, which are particularly important to improved attenuation performance, depending upon the choice of radiation energy range, are discussed. This effort contributes to the Los Alamos National Laboratory Continuous Improvement Program by improving the efficiency, cost effectiveness, and formality of glovebox operations.

  5. Determination of skin dose reduction by lead equivalent gloves

    International Nuclear Information System (INIS)

    Norriza Mohd Isa; Abd Aziz Mhd Ramli

    2006-01-01

    Radiation protective gloves are always used in medical facilities to protect radiation workers from unnecessary radiation exposure. A study on radiation protection gloves which are produced by local company had been performed by the Medical Physics Group, MINT. The gloves were made of lead equivalent material, as the attenuating element. The gloves were evaluated in term of the percentage of skin dose reduction by using a newly developed procedure and facilities in MINT. Attenuation measurements of the gloves had been carried out using direct beams and scattered radiations of different qualities. TLD rings were fitted on finger phantom; and water phantom were used in the measurement. The result were obtained and analysed based on data supplied by manufacturer. (Author)

  6. Integrity of Disposable Nitrile Exam Gloves Exposed to Simulated Movement

    Science.gov (United States)

    Phalen, Robert N.; Wong, Weng Kee

    2011-01-01

    Every year, millions of health care, first responder, and industry workers are exposed to chemical and biological hazards. Disposable nitrile gloves are a common choice as both a chemical and physical barrier to these hazards, especially as an alternative to natural latex gloves. However, glove selection is complicated by the availability of several types or formulations of nitrile gloves, such as low-modulus, medical-grade, low-filler, and cleanroom products. This study evaluated the influence of simulated movement on the physical integrity (i.e., holes) of different nitrile exam glove brands and types. Thirty glove products were evaluated out-of-box and after exposure to simulated whole-glove movement for 2 hr. In lieu of the traditional 1-L water-leak test, a modified water-leak test, standardized to detect a 0.15 ± 0.05 mm hole in different regions of the glove, was developed. A specialized air inflation method simulated bidirectional stretching and whole-glove movement. A worst-case scenario with maximum stretching was evaluated. On average, movement did not have a significant effect on glove integrity (chi-square; p=0.068). The average effect was less than 1% between no movement (1.5%) and movement (2.1%) exposures. However, there was significant variability in glove integrity between different glove types (p ≤ 0.05). Cleanroom gloves, on average, had the highest percentage of leaks, and 50% failed the water-leak test. Low-modulus and medical-grade gloves had the lowest percentages of leaks, and no products failed the water-leak test. Variability in polymer formulation was suspected to account for the observed discrepancies, as well as the inability of the traditional 1-L water-leak test to detect holes in finger/thumb regions. Unexpectedly, greater than 80% of the glove defects were observed in the finger and thumb regions. It is recommended that existing water-leak tests be re-evaluated and standardized to account for product variability. PMID:21476169

  7. Decontamination of latex gloves

    International Nuclear Information System (INIS)

    Boutot, P.; Schipfer, P.; Blachere, A.

    1969-01-01

    Initially the latex gloves used in controlled zones were processed after use as radioactive waste. In view of the continually increasing number used, however, the persons in charge of the SPRAR have considered the possibility of decontaminating the gloves and using them again after control. The recovery installations which have been developed were initially designed rather crudely and operated irregularly; they have been progressively improved as a result of the experience acquired; today they are more really an industrial concern, equipped with automatic machinery. In 1967 it has been possible with this set-up to recover 247000 pairs of gloves, representing nearly 70 per cent of the number treated. (author) [fr

  8. Radio opaque gloves

    International Nuclear Information System (INIS)

    Whittaker, A.V.; Whittaker, R.E. Jr.; Goldstrom, R.A.; Shipko, F.J.

    1975-01-01

    Radiation shielding garments and accessories, such as radio-opaque gloves for surgeons, shielding against the harmful x-ray radiation in a fluoroscopic zone, are advantageously different from garments for shielding from other medical uses of x-rays. Such garments are provided with zones of differing opacity, whereby desired sensitivity and ''feel'' through the glove material is retained. One feature is the provision of an ''opacity gradient'' across the glove cross section with opacity being relatively low at the fingertip area (lesser shield-thickness), but relatively high at the less nonprehensile hand zones, such as the palm. Glove fabrication techniques for achieving such an opacity gradient are described. (U.S.)

  9. Develop and Manufacture an Ergonomically Sound Glovebox Glove Report

    Energy Technology Data Exchange (ETDEWEB)

    Lawton, Cindy M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-10-18

    Ergonomic injury and radiation exposure are two safety concerns for the Plutonium Facility at Los Alamos National Laboratory (LANL). This facility employs the largest number of gloveboxes (GB) at LANL with approximately 6000 gloves installed. The current GB glove design dates back to the 1960’s and is not based on true hand anatomy, revealing several issues: short fingers, inappropriate length from the wrist to finger webbing, nonexistent joint angles and incorrect thumb placement. These design flaws are directly related to elbow (lateral epicondylitis) and thumb (DeQuervain’s tenosynovitis) injuries. The current design also contributes to increased wear on the glove, causing unplanned glove openings (failures) which places workers at risk of exposure. An improved glovebox glove design has three significant benefits: 1) it will reduce the risk of injury, 2) it will improve comfort and productivity, and 3) it will reduce the risk of a glovebox failures. The combination of these three benefits has estimated savings of several million dollars. The new glove design incorporated the varied physical attributes of workers ranging from the 5th percentile female to the 95th percentile male. Anthropometric hand dimensions along with current GB worker dimensions were used to develop the most comprehensive design specifications for the new glove. Collaboration with orthopedic hand surgeons also provided major contributtions to the design. The new glovebox glove was developed and manufactured incorporating over forty dimensions producing the most comprehensive ergonomically sound design. The new design received a LANL patent (patent attorney docket No: LANS 36USD1 “Protective Glove”, one of 20 highest patents awarded by the Richard P. Feynman Center for Innovation. The glove dimensions were inputed into a solid works model which was used to produce molds. The molds were then shipped to a glove manufacturer for production of the new glovebox gloves. The new

  10. Design of a new non-sterile glove-dispensing unit to reduce touch-based contamination

    Directory of Open Access Journals (Sweden)

    Jennifer R Amos

    2014-06-01

    Full Text Available Background Despite best efforts by healthcare providers to sterilise their hands through hand washing prior to touching medical equipment and patients, bacteria are still present and can be spread through physical contact. We aimed to reduce the spread of touch-induced and airborne bacteria and virus spreading by using a touch-free glove-dispensing system that minimally exposes gloves in the box to air. Method The team met multiple times to undertake early prototyping and present ideas for the design. We experimented with folding gloves in varying patterns, similar to facial tissue-dispensing boxes, and tried several methods of opening/closing the glove box to determine the most effective way to access gloves with the least amount of physical contact. We considered the user experience and obtained user feedback after each design iteration. Results Ultimately, we decided on a vertically oriented box with optional holes for dispensing a glove on the side of the box or on the bottom by means of the pull-down drawer mechanism. This system will dispense a single glove at a time to the user with the option of using a pull-down drawer trigger to decrease the likelihood of physical contact with unused gloves. Both methods dispense a single glove. Conclusion: By reducing physical contact between the healthcare practitioner and the gloves, we are potentially reducing the spread of bacteria. This glove box design ensures that gloves are not exposed to the air in the clinic or hospital setting, thereby further reducing spread of airborne germs. This could assist in decreasing the risk of nosocomial infections in healthcare settings.

  11. Dexterity test data contribute to proper glovebox over-glove use

    International Nuclear Information System (INIS)

    Cournoyer, Michael E.; Lawton, Cindy M.; Castro, Armanda M.; Costigan, Stephen A.; Apel, D.M.; Neal, G.E.; Castro, J.M.; Michelotti, R.A.

    2010-01-01

    Programmatic operations at the Los Alamos National Laboratory Plutonium Facility (TA-55) involve working with various amounts of plutonium and other highly toxic, alpha-emitting materials. The spread of radiological contamination on surfaces, airborne contamination, and excursions of contaminants into the operator's breathing zone are prevented through the use of a variety of gloveboxes (the glovebox, coupled with an adequate negative pressure gradient, provides primary confinement). The glovebox gloves are the weakest part of this engineering control. The Glovebox Glove Integrity Program, which controls glovebox gloves from procurement to disposal at TA-55, manages this vulnerability. A key element of this program is to consider measures that lower the overall risk of glovebox operations. Proper selection of over-gloves is one of these measures. Line management owning glovebox processes have the responsibility to approve the appropriate personal protective equipment/glovebox glove/over-glove combination. As low as reasonably achievable (ALARA) considerations to prevent unplanned glovebox glove openings must be balanced with glove durability and worker dexterity, both of which affect the final overall risk to the worker. In this study, the causes of unplanned glovebox glove openings, the benefits of over-glove features, the effect of over-gloves on task performance using standard dexterity tests, the pollution prevention benefits, and the recommended over-gloves for a task are presented.

  12. Present status of the Waste Safety Testing Facility

    International Nuclear Information System (INIS)

    Kikuchi, A.; Yamada, N.

    1993-01-01

    The Waste Safety Testing Facility (WASTEF) was established in 1981, in which the objective was to evaluate the confinement performance of glass and Synroc waste forms including high level waste (HLW). To this target, the following examinations have been typically carried out ; the fabrication and characterization of waste forms, the volatility test as a storage behavior and the leachability test as a disposal behavior. The facility is composed of three beta/gamma concrete cells, two alpha/gamma concrete cells, one lead cell and five glove boxes. The lead cell and glove boxes are of alpha/gamma type and attached to the alpha/gamma concrete cells No. 4 and No. 5, respectively. Several kinds of testing apparatus, measuring instruments and analytical equipments are located in the cells, the glove boxes and the examination rooms in the service area and operation room in the facility. Comparing with the other hot examination facilities in JAERI, WASTEF especially attends to different and particular works for investigating chemical behavior of waste forms. (author)

  13. Delayed reactions to reusable protective gloves.

    Science.gov (United States)

    Pontén, Ann; Dubnika, Inese

    2009-04-01

    The materials in plastic protective gloves are thought to cause less contact allergy than rubber gloves. Our aim was to estimate the frequency of delayed reactions to different types of reusable protective gloves among dermatitis patients. 2 x 2 cm pieces of polyvinyl chloride (PVC) gloves, nitrile gloves, and natural rubber latex (NRL) gloves were tested as is in consecutive dermatitis patients tested with the baseline series. Among 658 patients, 6 patients reacted to PVC gloves and 6 patients to the NRL gloves. None reacted to both these types of gloves. Five of six patients with reactions to rubber gloves reacted to thiuram mix in the baseline series. Delayed reactions to reusable PVC gloves may be as common as to reusable NRL gloves. In contrast to most reactions to the NRL glove, the reactions to the PVC glove had no obvious association with reactions to any allergen(s) in the baseline series.

  14. Formaldehyde in reusable protective gloves.

    Science.gov (United States)

    Pontén, Ann

    2006-05-01

    Due to the clinical findings in a single patient's case, formaldehyde was suspected to be present in clinically relevant levels in reusable protective gloves. Therefore, 9 types of gloves were investigated with the semi-quantitative chromotropic acid method. It was found that 6/9 gloves emitted some formaldehyde and that 4/9 gloves emitted > or =40 microg of formaldehyde. Most of the formaldehyde was found on the inside of the gloves. To get an indication of the clinical relevance, a comparison with a protective cream declared to contain the formaldehyde-releasing agent diazolidinyl urea was performed by comparing areas of gloves with areas of cream layers with thickness 1-2 mg/cm(2). It was found that the amounts of formaldehyde emitted from the gloves might be in the same range as emitted from a layer of cream.

  15. Glove-Enabled Computer Operations (GECO): Design and Testing of an Extravehicular Activity Glove Adapted for Human-Computer Interface

    Science.gov (United States)

    Adams, Richard J.; Olowin, Aaron; Krepkovich, Eileen; Hannaford, Blake; Lindsay, Jack I. C.; Homer, Peter; Patrie, James T.; Sands, O. Scott

    2013-01-01

    The Glove-Enabled Computer Operations (GECO) system enables an extravehicular activity (EVA) glove to be dual-purposed as a human-computer interface device. This paper describes the design and human participant testing of a right-handed GECO glove in a pressurized glove box. As part of an investigation into the usability of the GECO system for EVA data entry, twenty participants were asked to complete activities including (1) a Simon Says Games in which they attempted to duplicate random sequences of targeted finger strikes and (2) a Text Entry activity in which they used the GECO glove to enter target phrases in two different virtual keyboard modes. In a within-subjects design, both activities were performed both with and without vibrotactile feedback. Participants mean accuracies in correctly generating finger strikes with the pressurized glove were surprisingly high, both with and without the benefit of tactile feedback. Five of the subjects achieved mean accuracies exceeding 99 in both conditions. In Text Entry, tactile feedback provided a statistically significant performance benefit, quantified by characters entered per minute, as well as reduction in error rate. Secondary analyses of responses to a NASA Task Loader Index (TLX) subjective workload assessments reveal a benefit for tactile feedback in GECO glove use for data entry. This first-ever investigation of employment of a pressurized EVA glove for human-computer interface opens up a wide range of future applications, including text chat communications, manipulation of procedureschecklists, cataloguingannotating images, scientific note taking, human-robot interaction, and control of suit andor other EVA systems.

  16. Contaminated glove remover for rubber or synthetic gloves

    International Nuclear Information System (INIS)

    Counit, G.; Charvolin, M.

    1993-01-01

    The glove remover, especially for protective rubber or synthetic gloves used to handle toxic materials in the nuclear, chemical and other industries, consist of a housing with a chamber into which the gloved hand is inserted, an outer depression chamber and a perforated wall between the two. A vacuum unit creates a low pressure inside the chamber enabling the hand to be withdrawn from the glove, which is then drawn through the pipe into a container for disposal. The open end of the chamber is covered by a diaphragm which surrounds and seals the arm which is inserted into it with the gloved hand. The diaphragm can occupy three positions: closed, where it surrounds and seals the arm; open, allowing the hand to be inserted or withdrawn, and intermediate, when air can pass from the outside between the hand and glove. A similar chamber is used for removing boots

  17. Gloves, extra gloves or special types of gloves for preventing percutaneous exposure injuries in healthcare personnel.

    Science.gov (United States)

    Mischke, Christina; Verbeek, Jos H; Saarto, Annika; Lavoie, Marie-Claude; Pahwa, Manisha; Ijaz, Sharea

    2014-03-07

    Healthcare workers are at risk of acquiring viral diseases such as hepatitis B, hepatitis C and HIV through exposure to contaminated blood and body fluids at work. Most often infection occurs when a healthcare worker inadvertently punctures the skin of their hand with a sharp implement that has been used in the treatment of an infected patient, thus bringing the patient's blood into contact with their own. Such occurrences are commonly known as percutaneous exposure incidents. To determine the benefits and harms of extra gloves for preventing percutaneous exposure incidents among healthcare workers versus no intervention or alternative interventions. We searched CENTRAL, MEDLINE, EMBASE, NHSEED, Science Citation Index Expanded, CINAHL, NIOSHTIC, CISDOC, PsycINFO and LILACS until 26 June 2013. Randomised controlled trials (RCTs) with healthcare workers as the majority of participants, extra gloves or special types of gloves as the intervention, and exposure to blood or bodily fluids as the outcome. Two authors independently assessed study eligibility and risk of bias, and extracted data. We performed meta-analyses for seven different comparisons. We found 34 RCTs that included 6890 person-operations as participating units and reported on 46 intervention-control group comparisons. We grouped interventions as follows: increased layers of standard gloves, gloves manufactured with special protective materials or thicker gloves, and gloves with puncture indicator systems. Indicator gloves show a coloured spot when they are perforated. Participants were surgeons in all studies and they used at least one pair of standard gloves as the control intervention. Twenty-seven studies also included other surgical staff (e.g. nurses). All but one study used perforations in gloves as an indication of exposure. The median control group rate was 18.5 perforations per 100 person-operations. Seven studies reported blood stains on the skin and two studies reported self reported

  18. Space suit glove design with advanced metacarpal phalangeal joints and robotic hand evaluation.

    Science.gov (United States)

    Southern, Theodore; Roberts, Dustyn P; Moiseev, Nikolay; Ross, Amy; Kim, Joo H

    2013-06-01

    One area of space suits that is ripe for innovation is the glove. Existing models allow for some fine motor control, but the power grip--the act of grasping a bar--is cumbersome due to high torque requirements at the knuckle or metacarpal phalangeal joint (MCP). This area in particular is also a major source of complaints of pain and injury as reported by astronauts. This paper explores a novel fabrication and patterning technique that allows for more freedom of movement and less pain at this crucial joint in the manned space suit glove. The improvements are evaluated through unmanned testing, manned testing while depressurized in a vacuum glove box, and pressurized testing with a robotic hand. MCP joint flex score improved from 6 to 6.75 (out of 10) in the final glove relative to the baseline glove, and torque required for flexion decreased an average of 17% across all fingers. Qualitative assessments during unpressurized and depressurized manned testing also indicated the final glove was more comfortable than the baseline glove. The quantitative results from both human subject questionnaires and robotic torque evaluation suggest that the final iteration of the glove design enables flexion at the MCP joint with less torque and more comfort than the baseline glove.

  19. Design of ventilation and air cleaning systems for the new Los Alamos Plutonium Facility

    International Nuclear Information System (INIS)

    Mitchell, R.; DeField, J.; Stafford, R.; McNeese, W.; Eberhardt, W.; Laushkin, N.

    1975-01-01

    The Los Alamos Scientific Laboratory's new plutonium facility will conform to AECM Appendix 6301-Part II, Section H-Minimum Design Criteria for New Plutonium Facilities. The glove box process exhaust air is filtered through three or four stages of HEPA filters. The design of this multi-stage filter installation is shown with a method of in-place testing of each stage individually. A glove box filter holder and the in-place test procedure is described. General room air from plutonium work areas is recirculated at the rate of eight air changes per hour with a 10 percent fresh air make-up. The filter plenums for the recirculated air are designed to permit in-place testing of each of the two filter stages. (U.S.)

  20. Decommissioning of the Risoe hot cell facility

    International Nuclear Information System (INIS)

    Carlsen, H.

    1992-02-01

    Concise descriptions of actions taken in relation to the decommissioning of the hot cell facility at Risoe National Laboratory are presented. The removal of fissile material, of large contaminated equipment from the concrete cell line and a separate shielded storage facility, and the removal of large contaminated facilities such as out cell parts of a tube transport system between a concrete cell and a lead shielded steel box and a remotely operated Reichert Telatom microscope housed in a lead shielded glove box is described in addition to the initial mapping of radiation levels related to the decontamination of concrete cells. The dose commitment of 17.7 mSv was ascribed to 12 persons in the 2nd half of 1991. The work resulting in these doses was mainly handling of waste together with the frogman entrances in order to repair the in-cell crane and power manipulator. The overall time schedule for the project still appears to be applicable. (AB)

  1. An Approach for Performance Based Glove Mobility Requirements

    Science.gov (United States)

    Aitchison, Lindsay; Benson, Elizabeth; England, Scott

    2016-01-01

    The Space Suit Assembly (SSA) Development Team at NASA Johnson Space Center has invested heavily in the advancement of rear-entry planetary exploration suit design but largely deferred development of extravehicular activity (EVA) glove designs, and accepted the risk of using the current flight gloves, Phase VI, for exploration missions. However, as design reference missions mature, the risks of using heritage hardware have highlighted the need for developing robust new glove technologies. To address the technology gap, the NASA Space Technology Mission Directorate's Game-Changing Development Program provided start-up funding for the High Performance EVA Glove (HPEG) Element as part of the Next Generation Life Support (NGLS) Project in the fall of 2013. The overarching goal of the HPEG Element is to develop a robust glove design that increases human performance during EVA and creates pathway for implementation of emergent technologies, with specific aims of increasing pressurized mobility to 60% of barehanded capability, increasing the durability in on-pristine environments, and decreasing the potential of gloves to cause injury during use. The HPEG Element focused initial efforts on developing quantifiable and repeatable methodologies for assessing glove performance with respect to mobility, injury potential, thermal conductivity, and abrasion resistance. The team used these methodologies to establish requirements against which emerging technologies and glove designs can be assessed at both the component and assembly levels. The mobility performance testing methodology was an early focus for the HPEG team as it stems from collaborations between the SSA Development team and the JSC Anthropometry and Biomechanics Facility (ABF) that began investigating new methods for suited mobility and fit early in the Constellation Program. The combined HPEG and ABF team used lessons learned from the previous efforts as well as additional reviews of methodologies in physical and

  2. Glove perforation rate with orthopedic gloving versus double gloving technique in tibial plateau leveling osteotomy: A randomized trial

    Science.gov (United States)

    Egeler, Kimberly; Stephenson, Nicole; Stanke, Natasha

    2016-01-01

    In this randomized, prospective study, perforation rates, glove change rates, and cost between orthopedic gloves (n = 227) and double gloving with standard latex surgical gloves (n = 178) worn in tibial plateau leveling osteotomy procedures were compared. Gloves were collected from the surgeon and surgical resident after procedures and were tested for perforations with a standardized water leak test, as described by the American Society for Testing and Materials International. No statistically significant difference was found between the perforation rate using orthopedic gloving and double gloving techniques (P = 0.629) or the rate at which gloves were changed (P = 0.146). Orthopedic gloving was 2.1 times more costly than double gloving but they may be preferred by surgeons for dexterity and comfort. PMID:27807378

  3. 76 FR 28308 - Compliance Policy Guide: Surgeons' Gloves and Patient Examination Gloves; Defects-Criteria for...

    Science.gov (United States)

    2011-05-17

    .... FDA-2011-D-0258] Compliance Policy Guide: Surgeons' Gloves and Patient Examination Gloves; Defects... Compliance Policy Guide Sec. 335.700, Surgeons' Gloves and Patient Examination Gloves; Defects--Criteria for... FDA staff on the submission of seizure recommendations for medical gloves that exceed the defect...

  4. Dexterity Test Data Contribute To Reduction in Leaded Glovebox Glove Use

    International Nuclear Information System (INIS)

    Cournoyer, M.E.; Lawton, C.M.; Castro, A.M.; Costigan, S.A.; Schreiber, S.

    2009-01-01

    Programmatic operations at the Los Alamos National Laboratory Plutonium Facility (TA-55) involve working with various amounts of plutonium and other highly toxic, alpha-emitting materials. The spread of radiological contamination on surfaces, airborne contamination, and excursions of contaminants into the operator's breathing zone are prevented through the use of a variety of gloveboxes. Using an integrated approach, controls have been developed and implemented through an efficient Glovebox Glove Integrity Program. A key element of this program is to consider measures that lower the overall risk of glovebox operations. Line management who own glovebox processes through this program make decisions on which type of glovebox gloves (hereafter referred to as gloves), the weakest component of this safety-significant system, would perform best in these aggressive environments. As Low as Reasonably Achievable considerations must be balanced with glove durability and worker dexterity, both of which affect the final overall risk of the operation. In the past, lead-loaded (leaded) gloves made from Hypalon R were the primary glove for programmatic operations at TA-55. Replacing leaded gloves with unleaded gloves for certain operations would lower the overall risk as well as reduce the amount of mixed transuranic waste. This effort contributes to the Los Alamos National Laboratory Continuous Improvement Program by improving the efficiency, cost-effectiveness, and formality of glovebox operations. In this report, the pros and cons of wearing leaded gloves, the effect of leaded gloves versus unleaded gloves on task performance using standard dexterity tests, the justification for switching from leaded to unleaded gloves, and the pollution prevention benefits of this dramatic change in the glovebox system are presented. (authors)

  5. Dexterity test data contribute to reduction in leaded glovebox gloves use

    Energy Technology Data Exchange (ETDEWEB)

    Cournoyer, Michael E [Los Alamos National Laboratory; Lawton, Cindy M [Los Alamos National Laboratory; Castro, Amanda M [Los Alamos National Laboratory; Costigan, Stephen A [Los Alamos National Laboratory; Schreiber, Stephen [Los Alamos National Laboratory

    2009-01-01

    Programmatic operations at the Los Alamos National Laboratory Plutonium Facility (T A-55) involve working with various amounts of plutonium and other highly toxic, alpha-emitting materials. The spread of radiological contamination on surfaces, airborne contamination, and excursions of contaminants into the operator's breathing zone are prevented through the use of a variety of gloveboxes. Using an integrated approach, controls have been developed and implemented through an efficient Glovebox Glove Integrity Program. A key element of this program is to consider measures that lower the overall risk of glovebox operations. Line management who own glovebox processes through this program make decisions on which type of glovebox gloves (hereafter referred to as gloves), the weakest component of this safety-significant system, would perform best in these aggressive environments. As Low as Reasonably Achievable considerations must be balanced with glove durability and worker dexterity, both of which affect the final overall risk of the operation. In the past, lead-loaded (leaded) gloves made from Hypalon(reg.) were the primary glove for programmatic operations at TA55. Replacing leaded gloves with unleaded gloves for certain operations would lower the overall risk as well as reduce the amount of mixed transuranic waste. This effort contributes to the Los Alamos National Laboratory Continuous Improvement Program by improving the efficiency, cost-effectiveness, and formality of glovebox operations. In this report, the pros and cons of wearing leaded gloves, the effect of leaded gloves versus unleaded gloves on task performance using standard dexterity tests, the justification for switching from leaded to unleaded gloves, and the pollution prevention benefits of this dramatic change in the glovebox system are presented.

  6. High Performance EVA Gloves (HPEG)

    Data.gov (United States)

    National Aeronautics and Space Administration — In collaboration with HEOMD's Human Research Program, we are researching mechanisms for hand injury and will be developing new gloves to significantly reduce injury...

  7. Dry boxes and inert atmosphere techniques

    International Nuclear Information System (INIS)

    Bartak, D.E.

    1987-01-01

    Practitioners need to conduct experiments with molten salts in an inert atmosphere owing to the chemical reactivity of these media. Most fused salt solvent systems show reactivity to water and/or oxygen, which results in significant chemical changes in the properties of these solvents. Although several studies on the nature of an oxygen/oxide electrode in this melt have been reported, the reactions have not been fully understood because of apparent water contamination in many cases. Nitrate melt systems are also hygroscopic; for example, the LiNO 3 -KNO 3 eutectic (177 0 C) absorbs water to at least 0.2% by weight. The result is that the electrochemistry of heavier, electropositive metal ions has been significantly altered. In addition, trace amounts of water have been shown to significantly affect the oxygen-oxide redox chemistry in NaNO 3 -KNO 3 melts (250 0 C). The haloaluminates, which include AlCl 3 -NaCl (175 0 C), as well as AlCl 3 -organic salt binaries are particularly sensitive to the presence of both oxygen and moisture. Oxygen is a strong oxidant in the fused hydroxide systems with formation of superoxide ion from either oxide or water. This chapter describes general, inert atmosphere techniques which can be used by the molten salt experimentalist. Because of the limitations of volatility, vacuum manipulations are not considered. Rather, the use of glove boxes, glove bags, and inert bench-top techniques are discussed. The areas covered are: glove box and bag equipment, operation and maintenance of glove boxes and glove bags, and common operations conducted inside glove boxes

  8. Decrease the Number of Glovebox Glove Breaches and Failures

    Energy Technology Data Exchange (ETDEWEB)

    Hurtle, Jackie C. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2013-12-24

    Los Alamos National Laboratory (LANL) is committed to the protection of the workers, public, and environment while performing work and uses gloveboxes as engineered controls to protect workers from exposure to hazardous materials while performing plutonium operations. Glovebox gloves are a weak link in the engineered controls and are a major cause of radiation contamination events which can result in potential worker exposure and localized contamination making operational areas off-limits and putting programmatic work on hold. Each day of lost opportunity at Technical Area (TA) 55, Plutonium Facility (PF) 4 is estimated at $1.36 million. Between July 2011 and June 2013, TA-55-PF-4 had 65 glovebox glove breaches and failures with an average of 2.7 per month. The glovebox work follows the five step safety process promoted at LANL with a decision diamond interjected for whether or not a glove breach or failure event occurred in the course of performing glovebox work. In the event that no glove breach or failure is detected, there is an additional decision for whether or not contamination is detected. In the event that contamination is detected, the possibility for a glove breach or failure event is revisited.

  9. Application of Spacesuit Glove Requirements Tools to Athletic and Personal Protective Equipment

    Science.gov (United States)

    England, Scott; Benson, Elizabeth; Melsoh, Miranda; Thompson, Shelby; Rajulu, Sudhakar

    2010-01-01

    Despite decades of ongoing improvement, astronauts must still struggle with inhibited dexterity and accelerated fatigue due to the requirement of wearing a pressurized Extra-Vehicular Activity (EVA) glove. Recent research in the Anthropometry and Biomechanics Facility at NASA's Johnson Space Center has focused on developing requirements for improvements in the design of the next generation of EVA glove. In the course of this research, it was decided to expand the scope of the testing to include a variety of commercially available athletic and consumer gloves to help provide a more recognizable comparison for investigators and designers to evaluate the current state of EVA glove mobility and strength. This comparison is being provided with the hope that innovative methods may help commercial development of gloves for various athletic and personal protective endeavors.

  10. Knitted outer gloves in primary hip and knee arthroplasty.

    Science.gov (United States)

    Tanner, J; Wraighte, P; Howard, P

    2006-01-01

    A randomised trial was carried out to determine the rate of perforation to inner gloves when comparing latex with knitted gloves during hip and knee arthroplasty. Members of the surgical team were randomised to wear either two pairs of latex gloves (standard double gloving) or a knitted glove on top of a latex glove. In addition, participants completed a visual analogue assessment of their overall satisfaction with the gloves. A total of 406 inner gloves were tested for perforations over a four-month period: 23% of inner gloves were perforated when latex outer gloves were used and 6% of inner gloves were perforated when knitted outer gloves were used. In total, there were 64 perforations to the inner gloves; only one of these perforations was detected by the glove wearer. Wearing knitted outer gloves during hip and knee arthroplasty statistically significantly reduces the risk of perforation to inner latex gloves (p<0.0001).

  11. Development of a test method for protective gloves against nanoparticles in conditions simulating occupational use

    International Nuclear Information System (INIS)

    Dolez, Patricia; Vinches, Ludwig; Vu-Khanh, Toan; Wilkinson, Kevin; Plamondon, Philippe

    2011-01-01

    Nanoparticle manufacture and use are in full expansion. The associated risks of occupational exposure raise large concerns due to their potential toxicity. Even if they stand as a last resort in the traditional occupational Health and Safety (H and S) risk management strategy, personal protective equipment (PPE) against nanoparticles are an absolute need in the context of precautionary principle advocated by H and S organizations worldwide. However no standard test method is currently available for evaluating the efficiency of PPE against nanoparticles, in particular in the case of gloves. A project is thus underway to develop a test method for measuring nanoparticle penetration through protective gloves in conditions simulating glove-nanoparticle occupational interaction. The test setup includes an exposure and a sampling chamber separated by a circular glove sample. A system of cylinders is used to deform the sample while it is exposed to nanoparticles. The whole system is enclosed in a glove box to ensure the operator safety during assembly, dismounting and clean-up operations as well as during the tests. Appropriate nanoparticle detection techniques were also identified. Results are reported here for commercial 15nm TiO2 nanoparticles - powder and colloidal solutions in 1,2-propanediol, ethylene glycol and water - and four types of protective gloves: disposable nitrile and latex as well as unsupported neoprene and butyl rubber gloves. They show that mechanical deformations and contact with colloidal solution liquid carriers may affect glove materials. Preliminary results obtained with TiO2 powder indicate a possible penetration of nanoparticles through gloves following mechanical deformations.

  12. Development of rubber gloves by radiation vulcanization

    International Nuclear Information System (INIS)

    Makuuchi, K.; Yoshii, F.; Ishigaki, I.; Mogi, M.; Saito, T.

    1990-01-01

    The processes of radiation vulcanization and production of protective rubber gloves for radioactive contamination are described. A newly developed sensitizing system consisting of 5 phr 2-ethylhexyl acrylate and 1 phr carbon tetrachloride was used to vulcanize natural rubber latex at 12 kGy. Transparent and soft gloves were obtained from the radiation vulcanized latex by a coagulant dipping process. The mechanical properties of the gloves meet Japanese Industrial Standard specification for protective gloves. Combustion analysis of the gloves revealed that the amount of evolved sulfur dioxide and remaining ashes are less than those from commercially available rubber gloves. A trial usage of the gloves at a nuclear power plant showed that the gloves were easy to use for delicate work without undergoing fatigue. (author)

  13. Glove Perforations During Interventional Radiological Procedures

    International Nuclear Information System (INIS)

    Leena, R. V.; Shyamkumar, N. K.

    2010-01-01

    Intact surgical gloves are essential to avoid contact with blood and other body fluids. The objective of this study was to estimate the incidence of glove perforations during interventional radiological procedures. In this study, a total of 758 gloves used in 94 interventional radiological procedures were examined for perforations. Eleven perforations were encountered, only one of which was of occult type. No significant difference in the frequency of glove perforation was found between the categories with varying time duration.

  14. Glove material, reservoir formation, and dose affect glove permeation and subsequent skin penetration

    DEFF Research Database (Denmark)

    Nielsen, Jesper Bo; Sørensen, Jens Ahm

    2012-01-01

    Protective gloves are used to reduce dermal exposure when managing chemical exposures at the work place. Different glove materials may offer different degrees of protection. The present study combined the traditional ASTM (American Society for Testing and Materials) model with the Franz diffusion...... cell to evaluate overall penetration through glove and skin as well as the deposition in the different reservoirs. Benzoic acid was applied on latex or nitrile gloves placed on top of human skin. The amounts of chemical were quantified in the glove material, between glove and skin, within the skin......, and in the receptor chamber. Both glove materials reduce total penetration of benzoic acid, but nitrile gloves offer a significantly better protection than latex gloves. This difference was less pronounced at the higher of the two concentrations of benzoic acid applied. Thus, glove types that offer relevant...

  15. A new glove for glovebox workers

    Energy Technology Data Exchange (ETDEWEB)

    Macdonald, J.M.; Nekimken, H.L.; Hermes, R.E.; Castro, J.M.; Evans, M.E.

    1996-10-01

    Lead-lined gloves used during the processing of nuclear materials within gloveboxes is an example of a barrier. To help prevent work contamination, current practice includes visual inspection and radiological monitoring of each glove on a regular basis. One administrative control requires radiological workers to monitor their hands upon removal form the glovebox gloves. In reality, either a catastrophic glove failure or the formation of pinholes can cause contamination which is detected after the fact. Real-time monitoring of glove integrity during use would help prevent the spread of contamination, minimize decontamination costs, and protect the glovebox worker. Another benefit of real-time monitoring is remotely alerting proper personnel of a glovebox glove breech. One of the most exciting aspects of this technology is the rapid detection of a breech in the glovebox glove. A puncture to a glove can be detected followed by an alert to a worker in less than a second. The benefits of a real-time monitoring system for glove integrity are immense. Examples of benefits using this new glove are: reducing work stoppage, personnel contamination, glovebox glove replacements, and the filing of costly reports. The primary application of this technology at Los Alamos National Laboratory would be protecting the worker with these newly designed lead-lined gloves.

  16. Flexible protective gloves: The emperor's new clothes

    International Nuclear Information System (INIS)

    Kelsey, C.A.; Mettler, F.A. Jr.

    1990-01-01

    The risk of developing skin cancer is estimated for interventional radiologists who do and do not wear thin, flexible protective leaded gloves. The use of these gloves is extremely expensive in terms of dollars per potential cancer prevented. Good radiographic practice without the use of flexible protective gloves provides adequate protection

  17. Mastitis Control: take up the gloves!

    NARCIS (Netherlands)

    Jansen, J.; Renes, R.J.; Lam, T.J.G.M.

    2009-01-01

    This study shows the results of a communication campaign to increase the use of milkers gloves at Dutch dairy farms. Wearing milkers gloves is recommended as a proper method to reduce the risk of transmitting infections during milking. In 2004 only 16 percent of the Dutch dairy farmer used gloves

  18. 21 CFR 878.4460 - Surgeon's glove.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Surgeon's glove. 878.4460 Section 878.4460 Food... DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4460 Surgeon's glove. (a) Identification. A surgeon's glove is a device made of natural or synthetic rubber intended to be worn by...

  19. Glove corrosive liquid immersion and permeability study

    International Nuclear Information System (INIS)

    Middleton, H.W.

    1977-01-01

    The Occupational Safety and Health Administration's requirement for protective equipment for personnel working with chemical hazards resulted in a study of gloves used in work with corrosive liquids. Gloves of different materials and weights were tested using ASTM methods, in various corrosive liquids. Results show the best material for gloves used for different lengths of time in the liquids

  20. Latex glove sensitivity amongst diagnostic imaging healthcare ...

    African Journals Online (AJOL)

    There are strong relationships between number of gloves used per day, duration of glove use and expression of symptoms. About 62.8% (n=76) of the respondents had previous knowledge of hypersensitivity reaction to latex gloves prior to this investigation. The paper concludes that latex hypersensitivity is a real problem ...

  1. Dexterity tests data contribute to reduction in leaded glovebox gloves use

    Energy Technology Data Exchange (ETDEWEB)

    Cournoyer, Michael E [Los Alamos National Laboratory; Lawton, Cindy M [Los Alamos National Laboratory; Castro, Amanda M [Los Alamos National Laboratory

    2008-01-01

    Programmatic operations at the Los Alamos National Laboratory Plutonium Facility (TA-55) involve working with various amounts of plutonium and other highly toxic, alphaemitting materials. The spread of radiological contamination on surfaces and airborne contamination and excursions of contaminants into the operator's breathing zone are prevented through the use of a variety of gloveboxes. Through an integrated approach, controls have been developed and implemented through an efficient Glovebox Glove Integrity Program (GGJP). A key element of this program is to consider measures that lower the overall risk of glovebox operations. Line management owning glovebox processes through this program make decisions on which type of glovebox gloves (the weakest component of this safety significant system) would perform in these aggressive environments. As Low As Reasonably Achievable (ALARA) considerations must be balanced with glove durability and worker dexterity, both of which affect the final overall risk of the operation. In the past, lead-loaded (leaded) glovebox gloves made from Hypalon(reg.) had been the workhorse of programmatic operations at TA-55. Replacing leaded gloves with unleaded gloves for certain operations would lower the overall risk as well as reduced the amount of mixed TRU waste. This effort contributes to Los Alamos National Laboratory Continuous Improvement Program by improving the efficiency, cost effectiveness, and formality of glovebox operations. In the following report, the pros and cons of wearing leaded glovebox gloves, the effect of leaded gloves versus unleaded gloves on task performance using standard dexterity tests, the justification for switching from leaded to unleaded gloves, and pollution prevention benefits of this dramatic change in the glovebox system are presented.

  2. Nuclear vacuum-cleaner with decloggable filter for glove boxes

    International Nuclear Information System (INIS)

    Jean Paul Mathieu

    2006-01-01

    This paper describes the development of a new vacuum-cleaner designed with a decloggable filter and motorization fan shift on external. This development has been performed in partnership by AREVA recycling Business Unit, AREVA Cleanup Business Unit, MONDIATECH and ROBOTICS companies. This development improves ergonomics, performances and reduces the volume of wastes. Two patent applications have been filed on this new vacuum-cleaner. (author)

  3. Efficacy of Heated Glove Liners

    National Research Council Canada - National Science Library

    Santee, William

    2000-01-01

    .... It should therefore increase. The issue Light-duty glove (LD), Trigger-finger mitten (TF) and Arctic Mitten (AM), were tested as 2-layer systems at simulated altitudes of sea level, 2500 m and 5000 m in still air and at 5 m s-1 on a biophysical hand model...

  4. An improved experimental methodology to evaluate the effectiveness of protective gloves against nanoparticles in suspension.

    Science.gov (United States)

    Vinches, Ludwig; Zemzem, Mohamed; Hallé, Stéphane; Peyro, Caroline; Wilkinson, Kevin J; Tufenkji, Nathalie

    2017-07-01

    Recent studies underline the potential health risks associated to the "nano" revolution, particularly for the workers who handle engineered nanoparticles (ENPs) that can be found in the formulation of several commercial products. Although many Health & Safety agencies recommend the use of protective gloves against chemicals, few studies have investigated the effectiveness of these gloves towards nanoparticle suspensions. Moreover, the data that are available are often contradictory. This study was designed to evaluate the effectiveness of protective gloves against nanoparticles in suspension. For this purpose, a new methodology was developed in order to take into account parameters encountered in the workplace such as mechanical deformations (MD) that simulate hand flexion and sweat. The effects of the precise experimental protocol on the concentrations of nanoparticles that were detected in the sampling suspension were assessed. Several samples of nitrile rubber gloves (73 µm thick), taken from different boxes, were brought into contact with gold nanoparticles (5 nm) in water. During their exposure to ENPs, the glove samples submitted systematic mechanical deformations and were placed in contact with a physiological solution simulating human sweat. Under these conditions, results obtained by inductively coupled plasma mass spectrometry (ICPMS) showed that the 5 nm gold nanoparticles passed through the protective gloves. This result was acquired, in spite of the observation of significant losses during the sampling phase that will be important for future experiments evaluating the effectiveness of these materials.

  5. FY13 High Performance EVA Glove (HPEG) Collaboration: Glove Injury Data Mining Effort - Training Data Overview

    Science.gov (United States)

    Reid, Christopher; Benson, Elizabeth; England, Scott; Charvat, Jacqueline; Norcross, Jason; McFarland, Shane; Rajulu, Sudhakar

    2014-01-01

    From the time hand-intensive tasks were first created for EVAs, discomforts and injuries have been noted.. There have been numerous versions of EVA gloves for US crew over the past 50 years, yet pain and injuries persist. The investigation team was tasked with assisting in a glove injury assessment for the High Performance EVA Glove (HPEG) project.center dot To aid in this assessment, the team was asked to complete the following objectives: - First, to develop the best current understanding of what glove-related injuries have occurred to date, and when possible, identify the specific mechanisms that caused those injuries - Second, to create a standardized method for comparison of glove injury potential from one glove to another. center dot The overall goal of the gloved hand injury assessment is to utilize ergonomics in understanding how these glove injuries are occurring, and to propose mitigations to current designs or design changes in the next generation of EVA gloves.

  6. Glove material, reservoir formation, and dose affect glove permeation and subsequent skin penetration.

    Science.gov (United States)

    Nielsen, Jesper Bo; Sørensen, Jens Ahm

    2012-02-15

    Protective gloves are used to reduce dermal exposure when managing chemical exposures at the work place. Different glove materials may offer different degrees of protection. The present study combined the traditional ASTM (American Society for Testing and Materials) model with the Franz diffusion cell to evaluate overall penetration through glove and skin as well as the deposition in the different reservoirs. Benzoic acid was applied on latex or nitrile gloves placed on top of human skin. The amounts of chemical were quantified in the glove material, between glove and skin, within the skin, and in the receptor chamber. Both glove materials reduce total penetration of benzoic acid, but nitrile gloves offer a significantly better protection than latex gloves. This difference was less pronounced at the higher of the two concentrations of benzoic acid applied. Thus, glove types that offer relevant protection at low concentrations does not necessarily give appropriate protection at high concentrations. Significant amounts of benzoic acid could be extracted from the glove materials after exposure. If a chemical is accumulated in the glove material, reuse of single-use gloves should be cautioned. The reuse of gloves is generally not to be recommended without effective decontamination. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Virtual Box

    DEFF Research Database (Denmark)

    Davis, Hilary; Skov, Mikael B.; Stougaard, Malthe

    2007-01-01

    . This paper reports on the design, implementation and initial evaluation of Virtual Box. Virtual Box attempts to create a physical and engaging context in order to support reciprocal interactions with expressive content. An implemented version of Virtual Box is evaluated in a location-aware environment...

  8. Touch sensitivity with sterile standard surgical gloves and single-use protective gloves.

    Science.gov (United States)

    Tiefenthaler, W; Gimpl, S; Wechselberger, G; Benzer, A

    2006-10-01

    The purpose of this study was to evaluate touch sensitivity and static two-point discrimination of the dominant index and middle finger in 20 anaesthetists wearing no gloves, single-use protective gloves or sterile standard surgical gloves. Semmes-Weinstein filaments were used to measure cutaneous pressure thresholds, and a Two-Point-Discriminator to estimate static two-point discrimination. Wearing gloves significantly reduced touch sensitivity (p gloves. The results of our study suggest that the additional cost of sterile standard surgical gloves can not be justified in terms of touch sensitivity.

  9. High Performance EVA Glove Collaboration: Glove Injury Data Mining Effort

    Science.gov (United States)

    Reid, C. R.; Benson, E.; England, S.; Charvat, J.; Norcross, J. R.; McFarland, S. M.; Rajulu, S.

    2015-01-01

    Human hands play a significant role during Extravehicular Activity (EVA) missions and Neutral Buoyancy Lab (NBL) training events, as they are needed for translating and performing tasks in the weightless environment. Because of this high frequency usage, hand and arm related injuries are known to occur during EVA and EVA training in the NBL. The primary objectives of this investigation were to: 1) document all known EVA glove related injuries and circumstances of these incidents, 2) determine likely risk factors, and 3) recommend interventions where possible that could be implemented in the current and future glove designs. METHODS: The investigation focused on the discomforts and injuries of U.S. crewmembers who had worn the pressurized Extravehicular Mobility Unit (EMU) spacesuit and experienced 4000 Series or Phase VI glove related incidents during 1981 to 2010 for either EVA ground training or in-orbit flight. We conducted an observational retrospective case-control investigation using 1) a literature review of known injuries, 2) data mining of crew injury, glove sizing, and hand anthropometry databases, 3) descriptive statistical analyses, and finally 4) statistical risk correlation and predictor analyses to better understand injury prevalence and potential causation. Specific predictor statistical analyses included use of principal component analyses (PCA), multiple logistic regression, and survival analyses (Cox proportional hazards regression). Results of these analyses were computed risk variables in the forms of odds ratios (likelihood of an injury occurring given the magnitude of a risk variable) and hazard ratios (likelihood of time to injury occurrence). Due to the exploratory nature of this investigation, we selected predictor variables significant at p=0.15. RESULTS: Through 2010, there have been a total of 330 NASA crewmembers, from which 96 crewmembers performed 322 EVAs during 1981-2010, resulting in 50 crewmembers being injured inflight and 44

  10. Chemical Resistance of Disposable Nitrile Gloves Exposed to Simulated Movement

    Science.gov (United States)

    Phalen, Robert N.; Wong, Weng Kee

    2012-01-01

    Large discrepancies between laboratory permeation testing and field exposures have been reported, with indications that hand movement could account for a portion of these differences. This study evaluated the influence of simulated movement on chemical permeation of 30 different disposable nitrile glove products. Products were investigated out-of-box and with exposure to simulated whole-glove movement. Permeation testing was conducted using ethanol as a surrogate test chemical. A previously designed pneumatic system was used to simulate hand movement. No movement and movement tests were matched-paired to control for environmental conditions, as were statistical analyses. Permeation data were collected for a 30-min exposure period or until a breakthrough time (BT) and steady-state permeation rate (SSPR) could be determined. A third parameter, area under the curve at 30 min (AUC-30), was used to estimate potential worker exposure. With movement, a significant decrease in BT (p ≤ 0.05), ranging from 6–33%, was observed for 28 products. The average decrease in BT was 18% (p ≤ 0.001). With movement, a significant increase in SSPR (p ≤ 0.05), ranging from 1–78%, was observed with 25 products. The average increase in SSPR was 18% (p ≤ 0.001). Significant increases in AUC-30 (p ≤ 0.05), ranging from 23–277%, were also observed for all products where it could be calculated. On average, there was a 58% increase (p ≤ 0.001). The overall effect of movement on permeation through disposable nitrile gloves was significant. Simulated movement significantly shortened the BT, increased the SSPR, and increased the cumulative 30-min exposure up to three times. Product variability also accounted for large differences, up to 40 times, in permeation and cumulative exposure. Glove selection must take these factors into account. It cannot be assumed that all products will perform in a similar manner. PMID:23009187

  11. Is double-gloving really protective? A comparison between the glove perforation rate among perioperative nurses with single and double gloves during surgery.

    Science.gov (United States)

    Guo, Yue Ping; Wong, Po Ming; Li, Yi; Or, Peggy Pui Lai

    2012-08-01

    Surgical teams rely on surgical gloves as a barrier to protect themselves against blood-borne pathogenic infections during surgery. Double-gloving is adopted by surgeons to tackle the problem of glove perforation. Nevertheless, double-gloving is not practiced commonly by operating room nurses and there are only limited studies about double-gloving that targets only perioperative nurses. The aim of this research was to assess the effectiveness of double-gloving in protecting perioperative nurses by comparing the frequency of glove perforation between single-gloving and double-gloving groups. A prospective and randomized study was performed. Nurses were assigned randomly to single-gloved and double-gloved groups for comparison of the glove perforation rate. Water-leakage and air-inflation tests were used to detect glove perforation. Glove perforations was detected in 10 of 112 sets of single-gloves (8.9%) and 12 of 106 sets of outer gloves in the double-gloved group (11.3%). There was no inner double-glove perforation (0%). Glove perforations were found in 6 and 4 of the 112 sets of single-gloves for the first assistants (5.36%) and the scrub nurses (3.57%), and 5 and 7 of 106 sets of outer gloves in the double-gloved group for the first assistants (4.72%) and the scrub nurses (6.60%), respectively. The average occurrence of perforation was 69.8 minutes (range, 20-110 min) after the beginning of surgery. The sites of perforation were localized mostly on the left middle finger (42%) and the left ring finger (33.3%). Based on the findings of the study, double-gloving is indeed effective in protecting operating room nurses against blood-borne pathogen exposure. It should be introduced as a routine practice. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Preliminary Study on Effect of Chemical Composition Alteration on Elastic Recovery and Stress Recovery of Nitrile Gloves

    Directory of Open Access Journals (Sweden)

    Tan Kai Yang

    2018-01-01

    Full Text Available Nitrile gloves are widely used in the medical and automobile field due to its superiority in hypo-allergic component and chemical resistance over natural latex gloves. However, poor elastic recovery of nitrile glove to compressive force also creates an aesthetic issue for customers with high levels of wrinkling after removing from glove box. This paper demonstrates the preliminary study on the varies chemical composition such as crosslinking agents, sulphur and zinc oxide, the accelerator agent added during curing process, and the rubber filler Titanium Dioxide, on the elastic recovery and stress relaxation in nitrile gloves manufacturing. These chemical were studied at different concentration level comparing the high and low level versus the normal production range. Due to the inconsistency in the analysis technique on the surface imaging, the elastic recovery result was unable to be quantified and was not conclusive at this point. The cross linking agents, sulphur and zinc oxide, and the accelerator agent, played a significant role in the mechanical strength of the gloves. Increment of these chemicals result in higher tensile strength, but a reduction in the elasticity of the materials in which causes a lesser elongation at break percentage for the gloves. Both cross-linkers demonstrate different behaviour where higher sulphur content, provide higher stress relaxation (SR% yet zinc oxide shows otherwise.

  13. Device Assembly Facility (DAF) Glovebox Radioactive Waste Characterization

    International Nuclear Information System (INIS)

    Dominick, J L

    2001-01-01

    The Device Assembly Facility (DAF) at the Nevada Test Site (NTS) provides programmatic support to the Joint Actinide Shock Physics Experimental Research (JASPER) Facility in the form of target assembly. The target assembly activities are performed in a glovebox at DAF and include Special Nuclear Material (SNM). Currently, only activities with transuranic SNM are anticipated. Preliminary discussions with facility personnel indicate that primarily two distributions of SNM will be used: Weapons Grade Plutonium (WG-Pu), and Pu-238 enhanced WG-Pu. Nominal radionuclide distributions for the two material types are included in attachment 1. Wastes generated inside glove boxes is expected to be Transuranic (TRU) Waste which will eventually be disposed of at the Waste Isolation Pilot Plant (WIPP). Wastes generated in the Radioactive Material Area (RMA), outside of the glove box is presumed to be low level waste (LLW) which is destined for disposal at the NTS. The process knowledge quantification methods identified herein may be applied to waste generated anywhere within or around the DAF and possibly JASPER as long as the fundamental waste stream boundaries are adhered to as outlined below. The method is suitable for quantification of waste which can be directly surveyed with the Blue Alpha meter or swiped. An additional quantification methodology which requires the use of a high resolution gamma spectroscopy unit is also included and relies on the predetermined radionuclide distribution and utilizes scaling to measured nuclides for quantification

  14. Evaluation of the flexibility of protective gloves.

    Science.gov (United States)

    Harrabi, Lotfi; Dolez, Patricia I; Vu-Khanh, Toan; Lara, Jaime

    2008-01-01

    Two mechanical methods have been developed for the characterization of the flexibility of protective gloves, a key factor affecting their degree of usefulness for workers. The principle of the first method is similar to the ASTM D 4032 standard relative to fabric stiffness and simulates the deformations encountered by gloves that are not tight fitted to the hand. The second method characterizes the flexibility of gloves that are worn tight fitted. Its validity was theoretically verified for elastomer materials. Both methods should prove themselves as valuable tools for protective glove manufacturers, allowing for the characterization of their existing products in terms of flexibility and the development of new ones better fitting workers' needs.

  15. Glove holder system for containment shell

    International Nuclear Information System (INIS)

    Picco, B.

    1993-01-01

    A glove holder for an isolated chamber used e.g. for handling toxic or radioactive materials and made with at least one access port in its wall, equipped with a ring to which the glove is attached, has a sleeve which connects the ring to the glove proper and protects the forarm. The sleeve is in at least two sections, a first corrugated section and a second, supple section which is able to fold inside the first section. ADVANTAGE - Reduced costs and quantity of waste produced by enabling glove proper only to be replaced. (author)

  16. Double gloving to reduce surgical cross-infection.

    Science.gov (United States)

    Tanner, J; Parkinson, H

    2006-07-19

    The invasive nature of surgery, with its increased exposure to blood, means that during surgery there is a high risk of transfer of pathogens. Pathogens can be transferred through contact between surgical patients and the surgical team, resulting in post-operative or blood borne infections in patients or blood borne infections in the surgical team. Both patients and the surgical team need to be protected from this risk. This risk can be reduced by implementing protective barriers such as wearing surgical gloves. Wearing two pairs of surgical gloves, triple gloves, glove liners or cloth outer gloves, as opposed to one pair, is considered to provide an additional barrier and further reduce the risk of contamination. The primary objective of this review was to determine if additional glove protection reduces the number of surgical site or blood borne infections in patients or the surgical team. The secondary objective was to determine if additional glove protection reduces the number of perforations to the innermost pair of surgical gloves. The innermost gloves (next to skin) compared with the outermost gloves are considered to be the last barrier between the patient and the surgical team. We searched the Cochrane Wounds Group Specialised Register (January 2006), and the Cochrane Central Register of Controlled Trials (CENTRAL)(The Cochrane Library Issue 4, 2005). We also contacted glove manufacturing companies and professional organisations. Randomised controlled trials involving: single gloving, double gloving, triple gloving, glove liners, knitted outer gloves, steel weave outer gloves and perforation indicator systems. Both authors independently assessed the relevance and quality of each trial. Data was extracted by one author and cross checked for accuracy by the second author. Two trials were found which addressed the primary outcome, namely, surgical site infections in patients. Both trials reported no infections. Thirty one randomised controlled trials

  17. The construction of solid waste form test facility

    International Nuclear Information System (INIS)

    Park, Hun Hwee; Kim, Joon Hyung; Lee, Byung Jik; Koo, Jun Mo; Kim, Jeong Guk; Jung, In Ha

    1990-03-01

    The solid waste form test facility (SWFTF) to test and/or evaluate the characteristics of waste forms, such as homogeniety, mechanical properties, thermal properties, waste resistance and leachability, have been constructed, and some equipments for testing actual waste forms has been purchased; radiocative monitoring system, glove box for the manipulator repair room, and uninteruppted power supply system, et al. Classifications of radioactive wastes, basic requirements and criteria to be considered during waste management were also reviewed. Some of the described items above have been standardized for the purpose of indigenigation. Therefore, safety assurance of waste forms, as well as increase in the range of participating of domestic companies in construction of further nuclear facilities could be obtained as results through constructing this facility. In the furture this facility is going to be utilized not only for the inspection of waste forms but also for the periodic decontamination for extending the life time of some expensive radiological equipments using remote handling techniques. (author)

  18. A pneumatic glove and immersive virtual reality environment for hand rehabilitative training after stroke.

    Science.gov (United States)

    Connelly, Lauri; Jia, Yicheng; Toro, Maria L; Stoykov, Mary Ellen; Kenyon, Robert V; Kamper, Derek G

    2010-10-01

    While a number of devices have recently been developed to facilitate hand rehabilitation after stroke, most place some restrictions on movement of the digits or arm. Thus, a novel glove was developed which can provide independent extension assistance to each digit while still allowing full arm movement. This pneumatic glove, the PneuGlove, can be used for training grasp-and-release movements either with real objects or with virtual objects in a virtual reality environment. Two groups of stroke survivors, with seven subjects in each group, completed a six-week rehabilitation training protocol, consisting of three 1-h sessions held each week. One group wore the PneuGlove during training, performed both within a novel virtual reality environment and outside of it with physical objects, while the other group completed the same training without the device. Across subjects, significant improvements were observed in the Fugl-Meyer Assessment for the upper extremity (p < 0.001), the hand/wrist portion of the Fugl-Meyer Assessment (p < 0.001), the Box and Blocks test (p < 0.005), and palmar pinch strength (p < 0.005). While changes in the two groups were not statistically different, the group using the PneuGlove did show greater mean improvement on each of these measures, such as gains of 3.7 versus 2.4 points on the hand/wrist portion of the Fugl-Meyer Assessment and 14 N versus 5 N in palmar pinch.

  19. Bento Boxes

    Science.gov (United States)

    Hasio, Cindy

    2010-01-01

    Bento boxes are common objects in Japanese culture, designed to hold enough lunch for one person. They have individual compartments and sometimes multiple tiers for rice, vegetables, and other side dishes. They are made of materials ranging from wood, cloth, aluminum, or plastic. In general, the greater the number of foods, the better the box is…

  20. [The usage of protective gloves for routine disinfection of patient contact areas : An anonymous survey of work doctors and hygienists (infection control nurses, link nurses and physicians)].

    Science.gov (United States)

    Dittmann, Kathleen; Morch-Röder, Alexandra; Kramer, Axel; Kagel, Verena; Hübner, Nils-Olaf

    2017-10-01

    Disinfection, routinely carried out in healthcare facilities and known as "ongoing disinfection" or "untargeted disinfection", covers areas that are suspected of being contaminated with pathogen-containing material without being recognizable or visible in individual cases. The use of chemical resistant protective gloves is indispensable for surface disinfection. However, it is unclear if healthcare facilities set specific requirements regarding the selection and application of gloves. The usage of protective gloves for routine disinfection of patient contact areas was assessed in an anonymous cross-sectional study. Work doctors and hygienists (infection control nurses, link nurses and physicians) were queried by questionnaire. Disposable gloves were predominantly used, in most cases largely in accordance with EN 374. The most common glove material was nitrile. Glove change was mostly reported between rooms. Reprocessing of reusable gloves is inconsistent. Several professions are responsible for selecting protective gloves. Procedures for glove selection and application for disinfection of contact surfaces vary between the surveyed institutions. Therefore, more attention has to be paid to these three aspects in the future and these must be included in the hygiene plans.

  1. Influence of orthopedic reinforced gloves versus double standard gloves on contamination events during small animal orthopedic surgery.

    Science.gov (United States)

    Hayes, Galina; Singh, Ameet; Gibson, Tom; Moens, Noel; Oblak, Michelle; Ogilvie, Adam; Reynolds, Debbie

    2017-10-01

    To determine the influence of orthopedic reinforced gloves on contamination events during small animal orthopedic surgery. Prospective randomized controlled trial SAMPLE POPULATION: Two hundred and thirty-seven pairs of orthopedic gloves (474 gloves) and 203 pairs of double standard gloves (812 gloves) worn during 193 orthopedic procedures. Primary and assistant surgeons were randomized to wear either orthopedic reinforced gloves or double gloves. Gloves were leak tested to identify perforations at the end of procedures. Perforations detected intraoperatively or postoperatively were recorded. A contamination event was defined as at least one perforation on either hand for orthopedic reinforced gloves, or a perforation of both the inner and outer glove on the same hand for double gloves. Baseline characteristics between the 2 intervention groups were similar. There was no difference in contamination events between the double-gloved and orthopedic gloved groups (OR = 0.95, 95% CI = 0.49-1.87, P = .89). The same percentage of contamination events (8% glove pairs used) occurred in the double gloved group (17 contamination events) and in the orthopedic gloved group (19 contamination events). The odds of a contamination event increased by 1.02 (95% CI 1.01-1.03, P contamination events in small animal orthopedic procedures. Surgeons reluctant to double glove due to perceptions of decreased dexterity and discomfort may safely opt for wearing orthopedic gloves, which may improve their compliance. © 2017 The American College of Veterinary Surgeons.

  2. Pegasus Rocket Wing and PHYSX Glove Undergoes Stress Loads Testing

    Science.gov (United States)

    1997-01-01

    The Pegasus Hypersonic Experiment (PHYSX) Project's Pegasus rocket wing with attached PHYSX glove rests after load-tests at Scaled Composites, Inc., in Mojave, California, in January 1997. Technicians slowly filled water bags beneath the wing, to create the pressure, or 'wing-loading,' required to determine whether the wing could withstand its design limit for stress. The wing sits in a wooden triangular frame which serves as the test-rig, mounted to the floor atop the waterbags. Pegasus is an air-launched space booster produced by Orbital Sciences Corporation and Hercules Aerospace Company (initially; later, Alliant Tech Systems) to provide small satellite users with a cost-effective, flexible, and reliable method for placing payloads into low earth orbit. Pegasus has been used to launch a number of satellites and the PHYSX experiment. That experiment consisted of a smooth glove installed on the first-stage delta wing of the Pegasus. The glove was used to gather data at speeds of up to Mach 8 and at altitudes approaching 200,000 feet. The flight took place on October 22, 1998. The PHYSX experiment focused on determining where boundary-layer transition occurs on the glove and on identifying the flow mechanism causing transition over the glove. Data from this flight-research effort included temperature, heat transfer, pressure measurements, airflow, and trajectory reconstruction. Hypersonic flight-research programs are an approach to validate design methods for hypersonic vehicles (those that fly more than five times the speed of sound, or Mach 5). Dryden Flight Research Center, Edwards, California, provided overall management of the glove experiment, glove design, and buildup. Dryden also was responsible for conducting the flight tests. Langley Research Center, Hampton, Virginia, was responsible for the design of the aerodynamic glove as well as development of sensor and instrumentation systems for the glove. Other participating NASA centers included Ames Research

  3. Decommissioning of the Risoe Hot Cell facility

    International Nuclear Information System (INIS)

    Carlsen, H.

    1994-06-01

    Nuclear fuels have been handled and examined after irradiation by physical and chemical techniques, and radiotherapy sources, mainly 60 Co, have been produced at Risoe National Laboratory since 1964. The aims of decommissioning (during 1990-94, at IAEA Stage 2 level for reactors) were to obtain safe conditions for the remaining parts of the facility and to produce clean space areas for new projects. The facility comprises 6 concrete cells, several lead-shielded steel cells, glove boxes, shielded storage for waste, a remotely operated optical microscope, a frogman area for personnel access to the concrete cells, a decontamination facility, workshops and safety installations. All steel cells, glove boxes and the microscope were emptied and removed. The concrete cells were emptied of fissile material, scientific equipment, general tools and scrap. Decontamination should facilitate waste packing and reduce amount of waste to be stored temporarily at the Risoe waste treatment facility together with highly active waste. The concrete cells were cleaned remotely by wiping, hot spot removal, by mechanical means and vacuum cleaning. The interiors of 2 cells were decontaminated by high pressure water jetting. All master-slave manipulators and part of the contaminated ventilation system at the cells were removed. The cells are left in a non-ventilated state, connected to the atmosphere by an absolute filter. The main contaminants measured before cell closure were 60 Co, 137 Cs and alpha-emitters. Dismantling, decontamination waste disposal and received doses are described. Simple techniques involving low doses were found to be very effective. (AB)

  4. MINIMIZING GLOVEBOX GLOVE BREACHES, PART IV: CONTROL CHARTS

    International Nuclear Information System (INIS)

    Cournoyer, Michael E.; Lee, Michelle B.; Schreiber, Stephen B.

    2007-01-01

    At the Los Alamos National Laboratory (LANL) Plutonium Facility, plutonium. isotopes and other actinides are handled in a glovebox environment. The spread of radiological contamination, and excursions of contaminants into the worker's breathing zone, are minimized and/or prevented through the use of glovebox technology. Evaluating the glovebox configuration, the glovebo gloves are the most vulnerable part of this engineering control. Recognizing this vulnerability, the Glovebox Glove Integrity Program (GGIP) was developed to minimize and/or prevent unplanned openings in the glovebox environment, i.e., glove failures and breaches. In addition, LANL implement the 'Lean Six Sigma (LSS)' program that incorporates the practices of Lean Manufacturing and Six Sigma technologies and tools to effectively improve administrative and engineering controls and work processes. One tool used in LSS is the use of control charts, which is an effective way to characterize data collected from unplanned openings in the glovebox environment. The benefit management receives from using this tool is two-fold. First, control charts signal the absence or presence of systematic variations that result in process instability, in relation to glovebox glove breaches and failures. Second, these graphical representations of process variation detennine whether an improved process is under control. Further, control charts are used to identify statistically significant variations (trends) that can be used in decision making to improve processes. This paper discusses performance indicators assessed by the use control charts, provides examples of control charts, and shows how managers use the results to make decisions. This effort contributes to LANL Continuous Improvement Program by improving the efficiency, cost effectiveness, and formality of glovebox operations.

  5. Performance analysis of exam gloves used for aseptic rodent surgery.

    Science.gov (United States)

    LeMoine, Dana M; Bergdall, Valerie K; Freed, Carrie

    2015-05-01

    Aseptic technique includes the use of sterile surgical gloves for survival surgeries in rodents to minimize the incidence of infections. Exam gloves are much less expensive than are surgical gloves and may represent a cost-effective, readily available option for use in rodent surgery. This study examined the effectiveness of surface disinfection of exam gloves with 70% isopropyl alcohol or a solution of hydrogen peroxide and peracetic acid (HP-PA) in reducing bacterial contamination. Performance levels for asepsis were met when gloves were negative for bacterial contamination after surface disinfection and sham 'exertion' activity. According to these criteria, 94% of HP-PA-disinfected gloves passed, compared with 47% of alcohol-disinfected gloves. In addition, the effect of autoclaving on the integrity of exam gloves was examined, given that autoclaving is another readily available option for aseptic preparation. Performance criteria for glove integrity after autoclaving consisted of: the ability to don the gloves followed by successful simulation of wound closure and completion of stretch tests without tearing or observable defects. Using this criteria, 98% of autoclaved nitrile exam gloves and 76% of autoclaved latex exam gloves met performance expectations compared with the performance of standard surgical gloves (88% nitrile, 100% latex). The results of this study support the use of HP-PA-disinfected latex and nitrile exam gloves or autoclaved nitrile exam gloves as viable cost-effective alternatives to sterile surgical gloves for rodent surgeries.

  6. 30 CFR 77.606-1 - Rubber gloves; minimum requirements.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Rubber gloves; minimum requirements. 77.606-1... COAL MINES Trailing Cables § 77.606-1 Rubber gloves; minimum requirements. (a) Rubber gloves (lineman's gloves) worn while handling high-voltage trailing cables shall be rated at least 20,000 volts and shall...

  7. EVALUATION OF GLOVEBOX GLOVES FOR EFFECTIVE PERMEATION CONTROL

    Energy Technology Data Exchange (ETDEWEB)

    Korinko, P.

    2012-02-29

    A research and development task was undertaken to determine the permeabilities of hydrogen and dry air through different polymeric glove materials that are used to maintain the integrity of glovebox secondary containment. Fifteen different glove samples were obtained from four different manufacturers and samples cut from these gloves were tested. The gloves included baseline butyl rubber, Viton{reg_sign}, Dupont{reg_sign} Hypalon{reg_sign}, polyurethane, as well as composite gloves. The testing indicated that all of the vendor's butyl rubber gloves and the Jung Viton{reg_sign} gloves performed comparably in both gases.

  8. 21 CFR 800.20 - Patient examination gloves and surgeons' gloves; sample plans and test method for leakage defects...

    Science.gov (United States)

    2010-04-01

    ... glove, they are counted as one defect. Visual defects and leaks that are observed in the top 40... observed in the top 40 mm of a glove will not be counted as a defect for the purpose of this part. Visually... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Patient examination gloves and surgeons' gloves...

  9. A review of the materials and allergens in protective gloves.

    Science.gov (United States)

    Rose, Rebecca F; Lyons, Paul; Horne, Helen; Mark Wilkinson, S

    2009-09-01

    The ingredients previously reported to cause protective glove allergy are presented and evaluated for strength of evidence. Allergens that have caused both delayed hypersensitivity and contact urticaria are considered for rubber, plastic, leather, and textile gloves. The current guidelines regarding glove manufacture are described. A list of materials confirmed by the industry to be used in glove production is presented together with a suggested series for investigating patients with delayed type hypersensitivity and contact urticaria secondary to glove use.

  10. Channel box compression device

    International Nuclear Information System (INIS)

    Nakamizo, Hiroshi; Tanaka, Yuki.

    1996-01-01

    The device of the present invention reduces the volume of spent fuel channel boxes of power plant facilities to eliminate secondary wastes, suppress generation of radiation sources and improve storage space efficiency. The device has a box-like shape. A support frame is disposed on the lateral side of the box for supporting spent channel boxes. A horizontal transferring unit and a vertical transferring compression unit driven by a driving mechanism are disposed in the support frame. Further, the compression unit may have a rotational compression roller so as to move freely in the transferring unit. In addition, the transferring unit and the driving mechanism may be disposed outside of pool water. With such a constitution, since spent channel boxes are compressed and bent by horizontal movement of the transferring unit and the vertical movement of the compression unit, no cut pieces or cut powders are generated. Further, if the transferring unit and the driving mechanism are disposed outside of the pool water, it is not necessary to make them waterproof, which facilitates the maintenance. (I.S.)

  11. RoboGlove: Initial Work Toward a Robotically Assisted EVA Glove

    Science.gov (United States)

    Rogers, Jonathan

    2015-01-01

    The RoboGlove is a device designed to provide additional grip strength or endurance for a user. In applying this Robonaut 2 spinoff technology to the Phase VI Space Suit glove, the project is using robotic tendons and actuators to regain some of the hand performance that is lost when wearing a pressurized glove. An array of sensors embedded into the finger softgoods provides input to the control system which retracts the tendons, helping to close the user's hand. While active, this system provides augmentation, but is nonintrusive to glove usage when disabled.

  12. Innovative EVA Glove Exoskeleton, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Dexterous performance degradation resulting from donning an extra-vehicular activity (EVA) glove limits the capability of astronauts to perform certain tasks in...

  13. Requirements Analysis for the Protective GLoves System

    National Research Council Canada - National Science Library

    Schleper, Roger

    1999-01-01

    ...). The PGS is an Army Soldier Enhancement Program (SEP). The motivation for this SEP originated with a suggestion from a military engineer, which described some deficiencies of the current Barbed Wire Glove...

  14. High Pressure EVA Glove (HPEG), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Final Frontier Design's (FFD) High Pressure EVA Glove (HPEG) is a game changing technology enabling future exploration class space missions. The high operating...

  15. Evaluation of surgical gloves for radiation protection

    International Nuclear Information System (INIS)

    Antolin, E.; Rot, M.J.; Ordonez, J.; Arranz, L.; Sastre, J.M.; Ferrer, N.; Andres, J.C. de

    2006-01-01

    Full text of publication follows: Accumulated doses in hands during interventionist cardiology and radiological procedures can reach high values, and even go beyond legal limits for exposed professionals after years of work, unless they use specific radiation protection methods. An important protection mean for hands is the use of surgical gloves that attenuate the radiation while maintaining the tactile sensitivity demanded by physicians.There is a wide variety of commercialized gloves for radiation protection, with different advantages and disadvantages for various uses. In this paper nine different models of gloves have been evaluated for testing its attenuation capacity for several voltages, the maintenance of tactile sensitivity, its resistance to elongation, and the apparition of pores after successive sterilizing processes. It is very important that they do not lose its initial characteristics after processes of sterilization in order to optimize the product effective cost. The attenuation values have been measured under the voltages of 60, 70, 80 and 90 KVp obtaining very different values at each voltage with different gloves. The values measured range between 34 % before any supplementary sterilization with one model of glove (for 90 KVp), and 57 % after four sterilization processes with another glove (for 60 KVp). Some gloves lose its attenuation capacity after successive sterilizations, having not been found an y significant relation with their composition. The tactile sensitivity, a decisive factor for its users, decreases as its attenuation capacity increases, and remains mostly constant after being sterilized. The tests performed allow to conclude a set of fi nal results that can facilitate the choice of the most suitable gloves according to the practical applications (the priorities being the radiation protection and the tactile sensitivity)

  16. Whole glove permeation of cyclohexanol through disposable nitrile gloves on a dextrous robot hand: Fist clenching vs. non-clenching.

    Science.gov (United States)

    Mathews, Airek R; Que Hee, Shane S

    2017-04-01

    The differences in permeation parameters when a gloved dextrous robot hand clenched and did not were investigated with the dynamic permeation system described in the companion paper. Increased permeation through the gloves of the present study for cyclohexanol when the gloved hand clenched depended on glove thickness and porosity for cyclohexanol permeation. The Sterling glove, the thinnest and most porous, was the least protective. Hand clenching promoted more permeation for the Sterling glove in terms of breakthrough times, steady state permeation rate, and diffusion coefficient. The Safeskin glove showed increased permeation only for the steady state permeation rate but not breakthrough times or diffusion coefficient. The Blue and Purple gloves showed no differences when the hand was clenching or not. The correlational analysis supported differences between the clenching and non-clenching situations, and the risk assessment considered the worst and best scenarios relative to one and two hydrated hands that were and were not protected by specific gloves.

  17. Analytical chemistry in a new analytical hot cell facility

    International Nuclear Information System (INIS)

    Wade, M.A.; Dykes, F.W.; Goettsche, J.H.

    1985-01-01

    The Remote Analytical Laboratory is a new facility at the Idaho Chemical Processing Plant designed to handle samples from the processing of spent nuclear fuel. It consists of a cold laboratory for analyzing process make-up samples, a warm laboratory for analyzing low-level (<100 mR/h) radioactive samples, and a hot cell for analyzing high-level radioactive samples. The hot cell is built in an L shape and contains six work stations, each equipped with a viewing window and two master/slave manipulators. The cell interfaces with a waste handling cell and maintenance area on one end and a glove box complex that interfaces with the warm laboratory on the other end. This paper discusses the remote analytical techniques and equipment developed for use in this facility

  18. Health risk assessments of DEHP released from chemical protective gloves.

    Science.gov (United States)

    Chao, Keh-Ping; Huang, Chan-Sheng; Wei, Chung-Ying

    2015-01-01

    The substance di-2-ethylhexyl phthalate (DEHP) is widely used as a plasticizer in chemical protective gloves to improve their flexibility and workability. However, it is possible that workers using protective gloves to handle various solvents may be exposed to DEHP leached by the solvents. Using an ASTM F739 permeation cell, it was found that BTEX solvents permeating through the glove samples dissolved DEHP from the gloves. Even without continuously contacting the permeant, DEHP was released from the contaminated glove samples during the desorption experiments. The DEHP leaching amounts were found to be inversely correlated to the permeability coefficients of BTEX in the glove samples. This result implied that the larger the amount of DEHP released from the glove samples, the higher the permeation resistance of gloves. Although chemical protective gloves provide adequate skin exposure protection to workers, the dermal exposure model developed herein indicates that leaching of DEHP from the glove samples may pose a potential health risk to the workers who handle BTEX. This study suggests that the selection of protective gloves should not only be concerned with the chemical resistance of the gloves but also the health risk associated with leaching of chemicals, such as DEHP, used in the manufacturing of the gloves. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Permeation of Comite through protective gloves.

    Science.gov (United States)

    Zainal, Hanaa; Que Hee, Shane S

    2006-09-01

    The goal of the study was to assess how protective disposable (Safeskin) and chemical protective (Sol-Vex) nitrile gloves were against Comite emulsifiable concentrate formulation containing propargite (PROP) as active pesticidal ingredient, because there were no explicit recommendations for the gloves that should be worn for hand protection. The glove material was exposed in ASTM-type I-PTC-600 permeation cells at 30.0+/-0.5 degrees C, and gas chromatography-mass spectrometry used for PROP analysis. Aqueous solutions of Comite at 40.4 mg/mL permeated both Safeskin and Sol-Vex nitrile by 8h. Safeskin showed a mean PROP mass permeated of 176+/-27 microg after 8h compared with a mean mass permeated for Sol-Vex of 3.17+/-4.08 microg. Thus, Sol-Vex was about 56 times more protective than Safeskin for an 8-h exposure. However, the kinetics of the permeation revealed that Safeskin can be worn for at least 200 min before disposal. When undiluted Comite challenged both types of nitrile, much faster permeation was observed. Safeskin gloves showed two steady state periods. The first had lag times (t(l)) values of about 1h, although normalized breakthrough times (t(b)) were gloves exposed continuously to undiluted Comite permeated above the normalized breakthrough threshold beyond 2.7h. A risk assessment revealed that the PROP skin permeation rate of 7.1 ng cm(-2)h(-1) was much slower than the first steady state Safeskin glove P(s) of 62,000 ng cm(-2)h(-1). Infrared analysis showed that the glove surfaces were not degraded by the Comite challenge. The chemically protective Sol-Vex gloves protected adequately against undiluted formulation for about 2.7h, whereas they provided protection for nearly 8h when the formulation was diluted with water to the highest concentration for field application. In contrast, the disposable Safeskin gloves did not protect at all for the undiluted formulation, but did for 200 min when the formulation was diluted with water to the highest

  20. 21 CFR 880.6250 - Patient examination glove.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Patient examination glove. 880.6250 Section 880.6250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... Devices § 880.6250 Patient examination glove. (a) Identification. A patient examination glove is a...

  1. Methods for reducing energy dissipation in cosmetic gloves

    NARCIS (Netherlands)

    Herder, J.L.; Cool, J.C.; Plettenburg, D.H.

    1998-01-01

    For cosmetic reasons, hand prostheses are provided with cosmetic gloves. Their pleasing appearance, however, is accompanied by poor mechanical behavior, resulting in a negative influence on prosthesis operation. Glove stiffness is high and nonlinear, and internal friction in the glove material

  2. The durability of examination gloves used on intensive care units.

    Science.gov (United States)

    Hübner, Nils-Olaf; Goerdt, Anna-Maria; Mannerow, Axel; Pohrt, Ute; Heidecke, Claus-Dieter; Kramer, Axel; Partecke, Lars Ivo

    2013-05-20

    The use of examination gloves is part of the standard precautions to prevent medical staff from transmission of infectious agents between patients. Gloves also protect the staff from infectious agents originating from patients. Adequate protection, however, depends on intact gloves. The risk of perforation of examination gloves is thought to correlate with duration of wearing, yet, only very few prospective studies have been performed on this issue. A total number of 1500 consecutively used pairs of examination gloves of two different brands and materials (latex and nitrile) were collected over a period of two months on two ICU's. Used gloves were examined for micro perforations using the "water-proof-test" according to EN 455-1. Cox-regression for both glove types was used to estimate optimal changing intervals. Only 26% of gloves were worn longer than 15 min. The total perforation rate was 10.3% with significant differences and deterioration of integrity of gloves between brands (pgloves show marked differences in their durability that cannot be predicted based on the technical data routinely provided by the manufacturer. Based on the increase of micro perforations over time and the wearing behavior, recommendations for maximum wearing time of gloves should be given. Changing of gloves after 15 min could be a good compromise between feasibility and safety. HCWs should be aware of the benefits and limitations of medical gloves. To improve personal hygiene hand disinfection should be further encouraged.

  3. Re-usable low density polyethylene arm glove for puerperal ...

    African Journals Online (AJOL)

    kGy) sterilised all the gloves as postirradiation glove specimens showed no bacterial contamination. However, at doses up to 50 kGy gamma irradiation caused “strengthening” of the polyethylene gloves. While at doses greater than 50 kGy, ...

  4. 21 CFR 878.4470 - Surgeon's gloving cream.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Surgeon's gloving cream. 878.4470 Section 878.4470...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4470 Surgeon's gloving cream. (a) Identification. Surgeon's gloving cream is an ointment intended to be used to lubricate the user...

  5. Bacterial migration through punctured surgical gloves under real surgical conditions

    Directory of Open Access Journals (Sweden)

    Heidecke Claus-Dieter

    2010-07-01

    Full Text Available Abstract Background The aim of this study was to confirm recent results from a previous study focussing on the development of a method to measure the bacterial translocation through puncture holes in surgical gloves under real surgical conditions. Methods An established method was applied to detect bacterial migration from the operating site through the punctured glove. Biogel™ double-gloving surgical gloves were used during visceral surgeries over a 6-month period. A modified Gaschen-bag method was used to retrieve organisms from the inner glove, and thus-obtained bacteria were compared with micro-organisms detected by an intra-operative swab. Results In 20 consecutive procedures, 194 gloves (98 outer gloves, 96 inner gloves were examined. The rate of micro-perforations of the outer surgical glove was 10% with a median wearing time of 100 minutes (range: 20-175 minutes. Perforations occurred in 81% on the non-dominant hand, with the index finger most frequently (25% punctured. In six cases, bacterial migration could be demonstrated microbiologically. In 5% (5/98 of outer gloves and in 1% (1/96 of the inner gloves, bacterial migration through micro-perforations was observed. For gloves with detected micro-perforations (n = 10 outer layers, the calculated migration was 50% (n = 5. The minimum wearing time was 62 minutes, with a calculated median wearing time of 71 minutes. Conclusions This study confirms previous results that bacterial migration through unnoticed micro-perforations in surgical gloves does occur under real practical surgical conditions. Undetected perforation of surgical gloves occurs frequently. Bacterial migration from the patient through micro-perforations on the hand of surgeons was confirmed, limiting the protective barrier function of gloves if worn over longer periods.

  6. Home-based hand rehabilitation after chronic stroke: Randomized, controlled single-blind trial comparing the MusicGlove with a conventional exercise program.

    Science.gov (United States)

    Zondervan, Daniel K; Friedman, Nizan; Chang, Enoch; Zhao, Xing; Augsburger, Renee; Reinkensmeyer, David J; Cramer, Steven C

    2016-01-01

    Individuals with chronic stroke have limited options for hand rehabilitation at home. Here, we sought to determine the feasibility and efficacy of home-based MusicGlove therapy. Seventeen participants with moderate hand impairment in the chronic phase of stroke were randomized to 3 wk of home-based exercise with either the MusicGlove or conventional tabletop exercises. The primary outcome measure was the change in the Box and Blocks test score from baseline to 1 mo posttreatment. Both groups significantly improved their Box and Blocks test score, but no significant difference was found between groups. The MusicGlove group did exhibit significantly greater improvements than the conventional exercise group in motor activity log quality of movement and amount of use scores 1 mo posttherapy (p = 0.007 and p = 0.04, respectively). Participants significantly increased their use of MusicGlove over time, completing 466 gripping movements per day on average at study end. MusicGlove therapy was not superior to conventional tabletop exercises for the primary end point but was nevertheless feasible and led to a significantly greater increase in self-reported functional use and quality of movement of the impaired hand than conventional home exercises. ClinicalTrials.gov; "Influence of Timing on Motor Learning"; NCT01769326; https://clinicaltrials.gov/ct2/show/NCT01769326.

  7. Granulomatous peritonitis caused by glove starch.

    OpenAIRE

    Michowitz, M.; Stavorovsky, M.; Ilie, B.

    1983-01-01

    Corn starch particles are used as a surgical glove lubricant. At present there is no better alternative for this lubricant. Implantation of corn starch particles into the peritoneal cavity can induce foreign body reactions, starch peritonitis and starch granulomata, and may cause adhesions and intestinal obstruction. Starch peritonitis should be treated conservatively.

  8. Latex glove sensitivity amongst diagnostic imaging healthcare ...

    African Journals Online (AJOL)

    kemrilib

    Latex glove sensitivity amongst diagnostic imaging healthcare personnel: a study in Southeastern Nigeria. Charles U. Eze1,* 1Augustine O. Okaro1 and Ivor C. Nwobi2. 1. Department of Medical Radiography and Radiological Sciences Faculty of Health Sciences and. Technology, University of Nigeria, Enugu Campus, ...

  9. Low-profile self-sealing sample transfer flexure box.

    Science.gov (United States)

    Simon, Kevin; Porz, Lukas; Swamy, Tushar; Chiang, Yet-Ming; Slocum, Alexander

    2017-08-01

    A flexural bearing mechanism has enabled the development of a self-sealing box for protecting air sensitive samples during transfer between glove boxes, micro-machining equipment, and microscopy equipment. The simplicity and self-actuating feature of this design makes it applicable to many devices that operate under vacuum conditions. The models used to design the flexural mechanism are presented in detail. The device has been tested in a Zeiss Merlin GEMINI II scanning electron microscope with Li 3 PS 4 samples, showing effective isolation from air and corrosion prevention.

  10. Permeation of Telone EC through protective gloves.

    Science.gov (United States)

    Zainal, Hanaa; Que Hee, Shane S

    2005-09-30

    Telone is a potent fumigant that is based on the chlorinated unsaturated hydrocarbon, 1,3-dichloropropene (1,3-DCP). It is often applied without dilution and so poses severe inhalation and air pollution threats. Urinary metabolites of 1,3-DCP have been detected after Telone skin exposure, so that preventing dermal exposure is also important. The objective of the study was to assess if nitrile and multi-layer ("laminated") gloves provide adequate protection against Telone EC formulation. To accomplish this, disposable (Safeskin) and chemically resistant (Sol-Vex) nitrile and laminated (Barrier mark and Silver Shield) glove materials were challenged by Telone EC with hexane liquid collection in an ASTM-type I-PTC-600 permeation cell. Analyses of cis- and trans-1,3-DCP in the collection fluid at specified times were performed on a moderately polar capillary column by gas chromatography-electron capture detection. Telone EC caused microholes in both nitrile materials, though the chemically protective material was degraded slower than the disposable nitrile. The laminated gloves offered limited protection. Silver Shield protected best because 1.5-2.3 mg 1,3-DCP permeated by 8 h relative to 2.5-7.6 mg for Barrier, implying about 2.5 times more protection for 8 h. Even for Silver Shield, the extent of protection was inadequate as illustrated by a risk assessment of the skin exposure situation. The normalized breakthrough times for both types of laminated gloves varied between 27 and 60 min. It is recommended that Viton gloves still be worn for protection.

  11. Wearing ambidextrous vinyl gloves does not impair manual dexterity.

    Science.gov (United States)

    Drabek, Tomas; Boucek, Charles D; Buffington, Charles W

    2013-01-01

    Universal precautions mandate that health care workers wear gloves to prevent the unintended spread of bloodborne pathogens. Gloves may affect manual dexterity, generally delaying task completion. Our previous study showed that wearing the wrong size latex surgical glove degraded manual dexterity. The use of non-sterile and non-latex gloves may limit certain risks and be more cost-effective. However, such gloves may produce different results. We hypothesized that ambidextrous vinyl examination gloves would degrade manual dexterity compared with bare hands. We studied 20 random subjects from a medical environment. Subjects performed a standard battery of Grooved Pegboard tasks while bare-handed, wearing ambidextrous non-sterile vinyl gloves that were their preferred size, a size too small, and a size too large. The order was randomized with a Latin Square design to minimize the effects of time, boredom, and fatigue on the subjects. Subjects were also invited to comment on the fit of different size gloves. Wearing vinyl gloves of both the preferred size and a size up or down failed to affect manual dexterity vs. bare hands on time to insert pegs, and pegs dropped during insertion or removal. In contrast, the time to remove pegs was reduced by wearing preferred size vinyl gloves compared with performing the task with bare hands (Pgloves that were too small caused significant hand discomfort. Vinyl gloves surprisingly do not degrade manual dexterity even when worn in ill-fitting sizes. Wearing a preferred size vinyl glove vs. bare hands may improve dexterity in selected tasks. Choosing a comfortable, large size seems the best strategy when the preferred size is unavailable. Thinner vinyl gloves may improve grip and may not degrade touch as much as latex surgical gloves and may thus represent a reasonable choice for selected tasks.

  12. Weapons Engineering Tritium Facility, Building 205, Technical Area 16: Los Alamos National Laboratory, Los Alamos, New Mexico

    International Nuclear Information System (INIS)

    1991-04-01

    The Weapons Engineering Tritium Facility (WETF) was planned by the US Department of Energy (DOE) to retain at Los Alamos National Laboratory the capability of repackaging small quantities of tritium to exacting specifications. Small quantities of tritium are required for energy research and development activities and for research on nuclear weapons test devices carried out as part of the laboratory mission. The WETF is an improved design proposed to replace an aging Los Alamos facility where tritium has been repackaged for many years. This Environmental Assessment evaluates the environmental consequences to be expected from operating the new facility, for which construction was completed in 1984, compared with those from continuing to operate the old facility. The document was prepared for compliance with NEPA. In operation, the WETF will incorporate state-of-the-art systems for containing tritium in glove boxes and capturing any tritium released into the glove box exhaust system and the laboratory atmosphere. Liquid discharges from the WETF would contain less than 1% of the tritium found in effluents from the present facility. Effluent streams would be surface discharges and would not enter the aquifer from which municipal water supplies are drawn. The quantity of solid radioactive waste generated at the WETF would be approximately the same as that generated at the present facility. The risk to the public from normal tritium-packaging operations would be significantly less from the WETF than from the present facility. The proposed action will reduce the adverse environmental impacts caused by tritium repackaging by substantially reducing the amount of tritium that escapes to the environment. 35 refs., 3 figs., 21 tabs

  13. Effects of Frequent Glove Change on Outcomes of Orthopaedic Surgical Procedures - A Multicenter Study on Surgical Gloves

    Directory of Open Access Journals (Sweden)

    Nishit Palo

    2017-10-01

    Full Text Available Introduction: Intact surgical gloves are a barrier to microorganisms migration between surgical team members and the patient. The surgical gloves are changed at various junctures but the effects of changing gloves during surgical procedures on various surgical parameters or clinical outcomes are not established. Aim: To determine rationale of glove change during orthopaedic procedures, differences amongst surgical parameters with and without changing the surgical gloves and whether frequent glove change affected surgical parameters or clinical outcomes. Materials and Methods: A prospective multicenter study conducted at three centers from January 2014 to January 2016. A 250 patients were divided into 2 groups (n=125 each in Group 1, surgical team operated with regular changing of gloves. In Group 2, only 1 set of double gloves were worn throughout the procedure. Surgical parameters or clinical outcomes were assessed for both the groups. Statistical analyses included the median, mode, range, Interquartile Range (IQR and sample standard deviation (s and independent-samples t-test. Bacterial counts were expressed as median with (IQR. Results: Surgical Timing Difference was 10 (S.D.- 4.2 minutes more in Group-1 (<0.05, Surgical Cost was higher in Group-1 by Rs.150-450 (<0.05. Outer glove micro-perforation rate was 5.85% and 8.15% in group-1 and 2 respectively with no inner glove perforation or Surgical Site Infections. Outer glove micro perforations were proportional to duration of surgery; operations lasting 120-210 and 61-120 minutes had 66.6% and 37.2% micro perforation rates respectively (p<0.05. Conclusion: Under standard operating conditions, procedures performed without glove change are shorter and cost effective than procedures performed with regular glove change with similar surgical and functional results. Judicious use of surgical gloves is a patient and environment friendly option, thereby reducing the hospital’s biomedical waste load.

  14. Do clinical examination gloves provide adequate electrical insulation for safe hands-on defibrillation? I: Resistive properties of nitrile gloves.

    Science.gov (United States)

    Deakin, Charles D; Lee-Shrewsbury, Victoria; Hogg, Kitwani; Petley, Graham W

    2013-07-01

    Uninterrupted chest compressions are a key factor in determining resuscitation success. Interruptions to chest compression are often associated with defibrillation, particularly the need to stand clear from the patient during defibrillation. It has been suggested that clinical examination gloves may provide adequate electrical resistance to enable safe hands-on defibrillation in order to minimise interruptions. We therefore examined whether commonly used nitrile clinical examination gloves provide adequate resistance to current flow to enable safe hands-on defibrillation. Clinical examination gloves (Kimberly Clark KC300 Sterling nitrile) worn by members of hospital cardiac arrest teams were collected immediately following termination of resuscitation. To determine the level of protection afforded by visually intact gloves, electrical resistance across the glove was measured by applying a DC voltage across the glove and measuring subsequent resistance. Forty new unused gloves (control) were compared with 28 clinical (non-CPR) gloves and 128 clinical (CPR) gloves. One glove in each group had a visible tear and was excluded from analysis. Control gloves had a minimum resistance of 120 kΩ (median 190 kΩ) compared with 60 kΩ in clinical gloves (both CPR (median 140 kΩ) and non-CPR groups (median 160 kΩ)). Nitrile clinical examination gloves do not provide adequate electrical insulation for the rescuer to safely undertake 'hands-on' defibrillation and when exposed to the physical forces of external chest compression, even greater resistive degradation occurs. Further work is required to identify gloves suitable for safe use for 'hands-on' defibrillation. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  15. Decommissioning experience of the reprocessing facility AT 1

    International Nuclear Information System (INIS)

    Montjoie, M.; Lurie, R.; Roger, J.

    1987-01-01

    AT1 was a pilot plant for reprocessing the mixed oxide fuel elements from the FBR program. It was operated successfully during ten years and definitively shut down in 1979. After two years of fissile material recovery and decontamination of the process line it was decided to decommission the unit to stage 3. Even though small in reprocessing capacity, it contained all the difficulties and specific problems of this type of facility, and needed the development of equipment such as: a remote controlled machine for dismantling the main cells; a modular α tight workshop to dismantle the glove boxes and α cells; and an α activity measurement station to be able to fit with the requirements of the disposal site. These activities are discussed

  16. Development of the Decommissioning Technology for Nuclear Facilities

    International Nuclear Information System (INIS)

    Lee, K. W.; Kim, G. N.; Kim, S. G.

    2010-04-01

    The evaluation technology of decommissioning process must be developed and will be used for the ALARA planning tool of decommissioning process and demonstrated for tools of decommissioning equipment. Also, this technology can be used for tools workplaces with high work difficulty such as large-scale chemical plant, under water and space. The monitoring system for high alpha radioactive contamination measurement will be use in the high radioactivity decommissioning sites such as hot-cell or glove box. Also, it will be use in the general nuclear facilities as the radiation monitoring unit. The preparation technology of the radiation sensor for high radioactive contamination measurement will be transferred to the company for the industrialization. The remote monitoring system can prevent the workers exposure using the optical fiber to separate the sensor and electronics

  17. Retraining and assessing hand movement after stroke using the MusicGlove: comparison with conventional hand therapy and isometric grip training.

    Science.gov (United States)

    Friedman, Nizan; Chan, Vicky; Reinkensmeyer, Andrea N; Beroukhim, Ariel; Zambrano, Gregory J; Bachman, Mark; Reinkensmeyer, David J

    2014-04-30

    It is thought that therapy should be functional, be highly repetitive, and promote afferent input to best stimulate hand motor recovery after stroke, yet patients struggle to access such therapy. We developed the MusicGlove, an instrumented glove that requires the user to practice gripping-like movements and thumb-finger opposition to play a highly engaging, music-based, video game. The purpose of this study was to 1) compare the effect of training with MusicGlove to conventional hand therapy 2) determine if MusicGlove training was more effective than a matched form of isometric hand movement training; and 3) determine if MusicGlove game scores predict clinical outcomes. 12 chronic stroke survivors with moderate hemiparesis were randomly assigned to receive MusicGlove, isometric, and conventional hand therapy in a within-subjects design. Each subject participated in six one-hour treatment sessions three times per week for two weeks, for each training type, for a total of 18 treatment sessions. A blinded rater assessed hand impairment before and after each training type and at one-month follow-up including the Box and Blocks (B & B) test as the primary outcome measure. Subjects also completed the Intrinsic Motivation Inventory (IMI). Subjects improved hand function related to grasping small objects more after MusicGlove compared to conventional training, as measured by the B & B score (improvement of 3.21±3.82 vs. -0.29±2.27 blocks; P=0.010) and the 9 Hole Peg test (improvement of 2.14±2.98 vs. -0.85±1.29 pegs/minute; P=0.005). There was no significant difference between training types in the broader assessment batteries of hand function. Subjects benefited less from isometric therapy than MusicGlove training, but the difference was not significant (P>0.09). Subjects sustained improvements in hand function at a one month follow-up, and found the MusicGlove more motivating than the other two therapies, as measured by the IMI. MusicGlove games scores correlated

  18. The effects of vibration-reducing gloves on finger vibration

    Science.gov (United States)

    Welcome, Daniel E.; Dong, Ren G.; Xu, Xueyan S.; Warren, Christopher; McDowell, Thomas W.

    2015-01-01

    Vibration-reducing (VR) gloves have been used to reduce the hand-transmitted vibration exposures from machines and powered hand tools but their effectiveness remains unclear, especially for finger protection. The objectives of this study are to determine whether VR gloves can attenuate the vibration transmitted to the fingers and to enhance the understanding of the mechanisms of how these gloves work. Seven adult male subjects participated in the experiment. The fixed factors evaluated include hand force (four levels), glove condition (gel-filled, air bladder, no gloves), and location of the finger vibration measurement. A 3-D laser vibrometer was used to measure the vibrations on the fingers with and without wearing a glove on a 3-D hand-arm vibration test system. This study finds that the effect of VR gloves on the finger vibration depends on not only the gloves but also their influence on the distribution of the finger contact stiffness and the grip effort. As a result, the gloves increase the vibration in the fingertip area but marginally reduce the vibration in the proximal area at some frequencies below 100 Hz. On average, the gloves reduce the vibration of the entire fingers by less than 3% at frequencies below 80 Hz but increase at frequencies from 80 to 400 Hz. At higher frequencies, the gel-filled glove is more effective at reducing the finger vibration than the air bladder-filled glove. The implications of these findings are discussed. Relevance to industry Prolonged, intensive exposure to hand-transmitted vibration can cause hand-arm vibration syndrome. Vibration-reducing gloves have been used as an alternative approach to reduce the vibration exposure. However, their effectiveness for reducing finger-transmitted vibrations remains unclear. This study enhanced the understanding of the glove effects on finger vibration and provided useful information on the effectiveness of typical VR gloves at reducing the vibration transmitted to the fingers. The new

  19. Development of holdup monitor system (HMOS) during facility maintenance

    International Nuclear Information System (INIS)

    Nakamura, Hironobu; Hosoma, Takashi; Tanaka, Izumi

    1999-01-01

    Holdup MOnitor System (HMOS) was developed for the purpose of verifying the constant holdup during facility maintenance in Plutonium Conversion Development Facility (PCDF). The glove box assay system (GBAS; big slab) has been used by inspectors, measures the holdup periodically (i.e. IIV) using coincidence counting. The GBAS couldn't be used for inspection during maintenance period. Because many glove boxes (GB) set in process area had been occupied by large vinyl green-houses due to maintenance. We aimed that the holdup except for the maintenance GB should be constant during maintenance period, the HMOSs were set to 3 GBs. The system had been used from June '98 to July '99 for verification. The HMOS detector is located top/bottom of the GB, counts total neutron variation in the GB continuously. Detector efficiencies are 1.2%(top) and 0.12%(bottom), respectively. The measurement variation is observed up to 1.5%(3σ). The HMOS has high sensitivity 8 to 90g Pu (3σ; In case of 1kg Pu holdup, the sensitivity depends on position in the GB). The movement of equipment or nuclear material from/in the GB can be detected effectively. Though the HMOS observes measurement variation related to humidity in the GB, hygroscopic effect of denitration MOX powder, material/equipment movement and mainly 241 Pu nuclear decay, this system can verify that the holdup is constant qualitatively. As a result, in PCDF, safeguard related to the inventory verification during maintenance period (more than 1 year) were successfully performed using holdup monitor system. (author)

  20. Boxing headguard performance in punch machine tests.

    Science.gov (United States)

    McIntosh, Andrew S; Patton, Declan A

    2015-09-01

    The paper presents a novel laboratory method for assessing boxing headguard impact performance. The method is applied to examine the effects of headguards on head impact dynamics and injury risk. A linear impactor was developed, and a range of impacts was delivered to an instrumented Hybrid III head and neck system both with and without an AIBA (Association Internationale de Boxe Amateur)-approved headguard. Impacts at selected speeds between 4.1 and 8.3 m/s were undertaken. The impactor mass was approximately 4 kg and an interface comprising a semirigid 'fist' with a glove was used. The peak contact forces were in the range 1.9-5.9 kN. Differences in head impact responses between the Top Ten AIBA-approved headguard and bare headform in the lateral and forehead tests were large and/or significant. In the 8.3 m/s fist-glove impacts, the mean peak resultant headform accelerations for bare headform tests was approximately 130 g compared with approximately 85 g in the forehead impacts. In the 6.85 m/s bare headform impacts, mean peak resultant angular head accelerations were in the range of 5200-5600 rad/s(2) and almost halved by the headguard. Linear and angular accelerations in 45° forehead and 60° jaw impacts were reduced by the headguard. The data support the opinion that current AIBA headguards can play an important role in reducing the risk of concussion and superficial injury in boxing competition and training. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  1. Dexterity testing of chemical-defense gloves. Technical report

    Energy Technology Data Exchange (ETDEWEB)

    Robinette, K.M.; Ervin; Zehner, G.F.

    1986-05-01

    Chemical-defense gloves (12.5-mil Epichlorohydron/Butyl, 14-mil Epichlorohydron/Butyl, and 7-mil Butyl with Nomex overgloves) were subjected to four dexterity tests (O'Connor Finger Dexterity Test, Pennsylvania Bi-Manual Worksample-Assembly, Minnesota Rate of Manipulation Turning, and the Crawford Small Test). Results indicated that subjects performances were most impaired by the 7-mil Butyl with Nomex overglove. Though differences between the other three gloved conditions were not always statistically significant, subjects performed silghtly better while wearing the Epichlorohydron/Butyl gloves, no matter which thickness, than they did while wearing the 15-mil butyl gloves. High negative correlation between anthropometry and gloved tests scores of subjects suggested that poor glove fit may also have affected subjects performances.

  2. Materials selection of surface coatings in an advanced size reduction facility

    International Nuclear Information System (INIS)

    Briggs, J.L.; Younger, A.F.

    1980-01-01

    A materials selection test program was conducted to characterize optimum interior surface coatings for an advanced size reduction facility. The equipment to be processed by this facility consists of stainless steel apparatus (e.g., glove boxes, piping, and tanks) used for the chemical recovery of plutonium. Test results showed that a primary requirement for a satisfactory coating is ease of decontamination. A closely related concern is the resistance of paint films to nitric acid - plutonium environments. A vinyl copolymer base paint was the only coating, of eight paints tested, with properties that permitted satisfactory decontamination of plutonium and also performed equal to or better than the other paints in the chemical resistance, radiation stability, and impact tests

  3. Identifying competencies of boxing coaches

    Directory of Open Access Journals (Sweden)

    Ioannis Tasiopoulos

    2014-10-01

    Full Text Available The purpose of this study was to find out the management skills required by boxing coaches to administrate their clubs. For the purposes of this study a scale was constructed which was answered by 98 boxing coaches. Explanatory factor analysis revealed seven factors: Communication-public relations (5 items, event management (4 items, management techniques (4 items, new technologies (4 items, prevention-safety (2 items, sport (5 items and sports facilities (2 items. The Cronbach of the scale was 0.85. The five competencies that rated by the coaches were: Supervisors of the area of training, maintaining excellent communication with athletes, using new technologies (e-mail, internet, handling disciplinary matters, accidents, complaints and reports on some sporting games and promoted harmony among athletes. We concluded that boxing coaches understand that the competencies required for meeting their obligations, were related to sports, prevention, safety and communications-public relations.

  4. Development of Wireless RFID Glove for Various Applications

    Science.gov (United States)

    Lee, Changwon; Kim, Minchul; Park, Jinwoo; Oh, Jeonghoon; Eom, Kihwan

    Radio Frequency Identification is increasingly popular technology with many applications. The majority of applications of RFID are supply-chain management. In this paper, we proposed the development of wireless RFID Glove for various applications in real life. Proposed wireless RFID glove is composed of RFID reader of 13.56 MHz and RF wireless module. Proposed Gloves were applied to two applications. First is the interactive leaning and second is Meal aid system for blind people. The experimental results confirmed good performances.

  5. Evaluating Utility Gloves as a Potential Reservoir for Pathogenic Bacteria.

    Science.gov (United States)

    Grant, Kathy L; Naber, E Donald; Halteman, William A

    2015-08-01

    This pilot study sought to determine the rate and degree to which gram-negative Klebsiella pneumoniae, Escherichia coli and Pseudomonas aeruginosa and gram-positive Staphylococcus aureus occurred on the inside of utility gloves used at University of Maine at Augusta, Dental Health Programs' dental hygiene clinic. Five steam autoclave utility gloves were randomly selected to serve as control and a convenience sample of 10 used utility gloves were selected from the sterilization area. A sample was collected from a predetermined surface area from the inside of each steam autoclave utility glove and used utility glove. Each sample was used to inoculate a Petri plate containing 2 types of culture media. Samples were incubated at 37° C for 30 to 36 hours in aerobic conditions. Colony forming units (CFU) were counted. Confidence intervals (CI) estimated the rate of contamination with gram-negative K. pneumoniae, E. coli and P. aeruginosa on the inside of steam autoclave utility gloves to be n=33 95% CL [0.000, 0.049], used utility gloves to be n=70, 95% CL [0.000, 0.0303]. Data estimated the rate of contamination with gram-positive S. aureus on the inside of steam autoclave utility gloves to be n=35, 95% CL [0.233, 0.530], used utility gloves to be n=70, 95% CL [0.2730, 0.4975]. Culture media expressed a wide range of CFU from 0 to over 200. The risk of utility glove contamination with gram-negative bacteria is likely low. The expressed growth of S. aureus from steam autoclave utility gloves controls raises questions about the effectiveness and safety of generally accepted sterilization standards for the governmentally mandated use of utility gloves. Copyright © 2015 The American Dental Hygienists’ Association.

  6. Handling chemotherapy drugs-Do medical gloves really protect?

    Science.gov (United States)

    Landeck, Lilla; Gonzalez, Ernesto; Koch, Olaf Manfred

    2015-10-15

    Due to their potential mutagenic, carcinogenic and teratogenic effects occupational exposure to chemotherapy drugs should be kept to a minimum. Utilization of personnel protective devices, especially the use of protective medical gloves, is a mainstay to avoid skin contact. The choice of appropriate gloves is of outstanding importance. For optimal protection in the oncology setting it is essential to establish general guidelines evaluating appropriate materials and defining quality standards. Establishing these guidelines can facilitate better handling and avoid potential hazards and late sequelae. In Europe there are no specific requirements or test methodologies for medical gloves used in the oncology environment. The implementation of uniform standards for gloves used while handling chemotherapy drugs would be desirable. In contrast, in the US medical gloves used to handle chemotherapy drugs have to fulfill requirements according to the ASTM International (American Society of Testing and Materials) standard D 6978-05. Nitrile or natural rubber latex is a preferred basic glove material, while vinyl is considered inappropriate because of its generally increased permeability. For extended exposure to chemotherapy drugs, double gloving, the use of thicker gloves and the frequent change of gloves increases their protective power. © 2014 UICC.

  7. The use of protective gloves by medical personnel.

    Science.gov (United States)

    Garus-Pakowska, Anna; Sobala, Wojciech; Szatko, Franciszek

    2013-06-01

    To minimize the risk of cross-infection between the patient and the medical staff, it is necessary to use individual protective measures such as gloves. According to the recommendations of the Centers for Disease Control and Prevention (CDC) and the World Health Organization (WHO), protective gloves should always be used upon contact with blood, mucosa, injured skin or other potentially infectious material. The aim of the study was to evaluate, through quasi-observation, the use of protective gloves by medical staff according to the guidelines issued by the CDC and WHO. The results were subject to statistical analysis (p gloves is demanded from the medical staff. The overall percentage of the observance of using gloves was 50%. The use of gloves depended significantly on the type of ward, profession, performed activity, number of situations that require wearing gloves during the observation unit and the real workload. During the entire study, as many as 718 contacts with patients were observed in which the same gloves were used several times. Wearing disposable protective gloves by the medical staff is insufficient.

  8. Computational Optimization of a Natural Laminar Flow Experimental Wing Glove

    Science.gov (United States)

    Hartshom, Fletcher

    2012-01-01

    Computational optimization of a natural laminar flow experimental wing glove that is mounted on a business jet is presented and discussed. The process of designing a laminar flow wing glove starts with creating a two-dimensional optimized airfoil and then lofting it into a three-dimensional wing glove section. The airfoil design process does not consider the three dimensional flow effects such as cross flow due wing sweep as well as engine and body interference. Therefore, once an initial glove geometry is created from the airfoil, the three dimensional wing glove has to be optimized to ensure that the desired extent of laminar flow is maintained over the entire glove. TRANAIR, a non-linear full potential solver with a coupled boundary layer code was used as the main tool in the design and optimization process of the three-dimensional glove shape. The optimization process uses the Class-Shape-Transformation method to perturb the geometry with geometric constraints that allow for a 2-in clearance from the main wing. The three-dimensional glove shape was optimized with the objective of having a spanwise uniform pressure distribution that matches the optimized two-dimensional pressure distribution as closely as possible. Results show that with the appropriate inputs, the optimizer is able to match the two dimensional pressure distributions practically across the entire span of the wing glove. This allows for the experiment to have a much higher probability of having a large extent of natural laminar flow in flight.

  9. Glove failure in elective thyroid surgery: A prospective randomized study

    Directory of Open Access Journals (Sweden)

    Dariusz Timler

    2015-06-01

    Full Text Available Objectives: To analyze perforation rate in sterile gloves used by surgeons in the operating theatre of the Department of Endocrinological and General Surgery of Medical University of Lodz. Material and Methods: Randomized and controlled trial. This study analyses the incidents of tears in sterile surgical gloves used by surgeons during operations on 3 types of thyroid diseases according to the 10th revision of International Statistical Classification of Diseases and Related Health Problems (ICD-10 codes. Nine hundred seventy-two pairs (sets of gloves were collected from 321 surgical procedures. All gloves were tested immediately following surgery using the water leak test (EN455-1 to detect leakage. Results: Glove perforation was detected in 89 of 972 glove sets (9.2%. Statistically relevant more often glove tears occurred in operator than the 1st assistant (p < 0.001. The sites of perforation were localized mostly on the middle finger of the non-dominant hand (22.5%, and the non-dominant ring finger (17.9%. Conclusions: This study has proved that the role performed by the surgeon during the procedure (operator, 1st assistant has significant influence on the risk of glove perforations. Nearly 90% of glove perforations are unnoticed during surgery.

  10. Initial Work Toward a Robotically Assisted EVA Glove

    Science.gov (United States)

    Rogers, J.; Peters, B.; McBryan, E.; Laske, E.

    2016-01-01

    The Space Suit RoboGlove is a device designed to provide additional grasp strength or endurance for an EVA crew member since gloved hand performance is a fraction of what the unencumbered human hand can achieve. There have been past efforts to approach this problem by employing novel materials and construction techniques to the glove design, as well as integrating powered assistance devices. This application of the NASA/GM RoboGlove technology uses a unique approach to integrate the robotic actuators and sensors into a Phase VI EVA glove. This design provides grasp augmentation to the glove user while active, but can also function as a normal glove when disabled. Care was taken to avoid adding excessive bulk to the glove or affecting tactility by choosing low-profile sensors and extrinsically locating the actuators. Conduits are used to guide robotic tendons from linear actuators, across the wrist, and to the fingers. The second generation of the SSRG includes updated electronics, sensors, and actuators to improve performance. The following discusses the electromechanical design, softgoods integration, and control system of the SSRG. It also presents test results from the first integration of a powered mobility element onto a space suit, the NASA Mark III. Early results show that sensor integration did not impact tactile feedback in the glove and the actuators show potential for reduction in grasp fatigue over time.

  11. The use of protective gloves by medical personnel

    Directory of Open Access Journals (Sweden)

    Anna Garus-Pakowska

    2013-06-01

    Full Text Available Introduction: To minimize the risk of cross-infection between the patient and the medical staff, it is necessary to use individual protective measures such as gloves. According to the recommendations of the Centers for Disease Control and Prevention (CDC and the World Health Organization (WHO, protective gloves should always be used upon contact with blood, mucosa, injured skin or other potentially infectious material. Materials and Methods: The aim of the study was to evaluate, through quasi-observation, the use of protective gloves by medical staff according to the guidelines issued by the CDC and WHO. The results were subject to statistical analysis (p < 0.05. Results: During 1544 hours of observations, 3498 situations were recorded in which wearing protective gloves is demanded from the medical staff. The overall percentage of the observance of using gloves was 50%. The use of gloves depended significantly on the type of ward, profession, performed activity, number of situations that require wearing gloves during the observation unit and the real workload. During the entire study, as many as 718 contacts with patients were observed in which the same gloves were used several times. Conclusion: Wearing disposable protective gloves by the medical staff is insufficient.

  12. A Dexterity and Tactility Evaluation of the Australian Nuclear Biological Chemical (NBC) Glove

    National Research Council Canada - National Science Library

    Scanlan, S

    2004-01-01

    This report details the tactility and dexterity of four different glove types, including the Australian in-service NBC butyl rubber glove and Nomex flying glove for standardized (Purdue pegboard) and operational...

  13. Glove use among hairdressers: difficulties in the correct use of gloves among hairdressers and the effect of education.

    Science.gov (United States)

    Oreskov, Katia W; Søsted, Heidi; Johansen, Jeanne D

    2015-06-01

    Hand eczema is frequent among Danish hairdressers, and they are advised to use gloves as protection. However, studies indicate that a significant proportion use gloves inappropriately. To determine whether hairdressers and apprentices use protective gloves in the correct way, and to determine whether a demonstration of correct use could cause an improvement. Forty-three hairdressers and apprentices were asked to perform a hair wash while wearing gloves. The shampoo used was contaminated with an ultraviolet (UV) trace material. Two rounds of hair washing were carried out by each person, interrupted by a demonstration of how to use gloves correctly. Photographs were taken to compare UV contamination before and after the demonstration. All of the participants (100%) had their hands contaminated during the first round; the area ranged between 0.02 and 101.37 cm(2) (median 3.62 cm(2)). In the second round, 55.8% were contaminated (range 0.00-3.08 cm(2) ; median 0.01 cm(2)). The reduction in contaminated skin areas was statistically significant (p glove demonstration. There were no significant differences between hairdressers and apprentices. Hairdressers and apprentices lack knowledge on how to handle gloves correctly. A short demonstration of correct glove use made a significant difference in the skin protection provided by gloves. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Binding and measuring natural rubber latex proteins on glove powder.

    Science.gov (United States)

    Tomazic-Jezic, Vesna J; Lucas, Anne D; Sanchez, Beatriz A

    2004-01-01

    Cornstarch used as a donning powder on natural rubber latex (NRL) gloves adsorbs NRL proteins. During glove use, powder-carried proteins can be aerosolized and can cause allergic reactions in NRL sensitized individuals. The amount of NRL proteins bound to glove powder and its relative relationship to the total amount of proteins on the glove has not been studied, due to the difficulty in measuring proteins on powder. Using the ELISA inhibition assay for NRL proteins [Standard test method for the immunological measurement of antigenic protein in natural rubber and its products. In: The Annual Book of ASTM Standards; ASTM: West Conshohocken, PA, 2000; ASTM D 64-0] we have investigated possible protocol modifications in order to include measurement of proteins bound to glove powder, as well as the water-extractable glove proteins. Possible interference of the starch itself was evaluated by adding clean cornstarch to the assay. No significant interference was observed with powder concentrations below 5 mg/mL. We analyzed 19 extracts of powdered surgical and examination gloves before and after removal of the particulate component. Comparison of NRL glove extracts with, and without, the cornstarch powder fraction indicated significant variations in the ratios of powder-bound protein and corresponding water-extractable protein. The ratios did not appear to correlate with either the total protein on the glove, the glove weight, or the total amount of powder on the glove. However, when virgin glove powders were exposed to NRL proteins, binding was proportional to the protein concentration in the suspension. Temperature in the range from 4 degrees C to 37 degrees C, did not affect binding intensity, while a higher pH resulted in a higher level of protein associated with, or bound to, the starch. The major differences in the propensity for NRL protein binding were observed among different glove powders. The data indicate that the amount of protein that binds to glove powder

  15. The Astronaut Glove Challenge: Big Innovation from a (Very) Small Team

    Science.gov (United States)

    Homer, Peter

    2008-01-01

    Many measurements were taken by test engineers from Hamilton Sundstrand, the prime contractor for the current EVA suit. Because the raw measurements needed to be converted to torques and combined into a final score, it was impossible to keep track of who was ahead in this phase. The final comfort and dexterity test was performed in a depressurized glove box to simulate real on-orbit conditions. Each competitor was required to exercise the glove through a defined set of finger, thumb, and wrist motions without any sign of abrasion or bruising of the competitor's hand. I learned a lot about arm fatigue! This was a pass-fail event, and both of the remaining competitors came through intact. After taking what seemed like an eternity to tally the final scores, the judges announced that I had won the competition. My glove was the only one to have achieved lower finger-bending torques than the Phase VI glove. Looking back, I see three sources of the success of this project that I believe also operate in other programs where small teams have broken new ground in aerospace technologies. These are awareness, failure, and trust. By remaining aware of the big picture, continuously asking myself, "Am I converging on a solution?" and "Am I converging fast enough?" I was able to see that my original design was not going to succeed, leading to the decision to start over. I was also aware that, had I lingered over this choice or taken time to analyze it, I would not have been ready on the first day of competition. Failure forced me to look outside conventional thinking and opened the door to innovation. Choosing to make incremental failures enabled me to rapidly climb the learning curve. Trusting my "gut" feelings-which are really an internalized accumulation of experiences-and my newly acquired skills allowed me to devise new technologies rapidly and complete both gloves just in time. Awareness, failure, and trust are intertwined: failure provides experiences that inform awareness

  16. Anthropomorphic Robot Hand And Teaching Glove

    Science.gov (United States)

    Engler, Charles D., Jr.

    1991-01-01

    Robotic forearm-and-hand assembly manipulates objects by performing wrist and hand motions with nearly human grasping ability and dexterity. Imitates hand motions of human operator who controls robot in real time by programming via exoskeletal "teaching glove". Telemanipulator systems based on this robotic-hand concept useful where humanlike dexterity required. Underwater, high-radiation, vacuum, hot, cold, toxic, or inhospitable environments potential application sites. Particularly suited to assisting astronauts on space station in safely executing unexpected tasks requiring greater dexterity than standard gripper.

  17. RE-USE AND LIFE SPAN OF GLOVES

    African Journals Online (AJOL)

    RE-USE AND LIFE SPAN OF GLOVES. W.H. van Palenstein Helderman. Department of Community and Preventive Dentistry. Faculty of Dentistry, Muhimbili University College of Health Sciences,. Dar es Salaam. Tanzania. Introduction. The use of gloves is a prerequisite for hygienic performed dental treatment since: 1.

  18. Haptic Glove Technology: Skill Development through Video Game Play

    Science.gov (United States)

    Bargerhuff, Mary Ellen; Cowan, Heidi; Oliveira, Francisco; Quek, Francis; Fang, Bing

    2010-01-01

    This article introduces a recently developed haptic glove system and describes how the participants used a video game that was purposely designed to train them in skills that are needed for the efficient use of the haptic glove. Assessed skills included speed, efficiency, embodied skill, and engagement. The findings and implications for future…

  19. High concentrations of natural rubber latex allergens in gloves used ...

    African Journals Online (AJOL)

    Introduction. Gloves made of natural rubber latex (NRL) are commonly used by healthcare workers because of their good qualities. However, allergic reactions to latex allergens are still commonly reported. Objective. To measure the concentrations of Hev b 1, Hev b 3, Hev b 5 and Hev b 6.02 allergens in gloves used by a ...

  20. Light transmission and air used for inspection of glovebox gloves

    International Nuclear Information System (INIS)

    Castro, Julio M.; Steckle, Warren P. Jr.; Macdonald, John M.

    2002-01-01

    Various materials used for manufacturing the glovebox gloves are translucent material such as hypalon, rubbers, and neoprene. This means that visible light can be transmitted through the inside of the material. Performing this test can help to increase visualization of the integrity of the glove. Certain flaws such as pockmarks, foreign material, pinholes, and scratches could be detected with increased accuracy. An analysis was conducted of the glovebox gloves obscure polymer material using a inspection light table. The fixture is equipped with a central light supply and small air pump to inflate the glove and test for leak and stability. A glove is affixed to the fixture for 360-degree inspection. Certain inspection processes can be performed: (1) Inspection for pockmarks and thin areas within the gloves; (2) Observation of foreign material within the polymer matrix; and (3) Measurements could be taken for gloves thickness using light measurements. This process could help reduce eyestrain when examining gloves and making a judgment call on the size of material thickness in some critical areas. Critical areas are fingertips and crotch of fingers.

  1. Design options for improving protective gloves for industrial assembly work.

    Science.gov (United States)

    Dianat, Iman; Haslegrave, Christine M; Stedmon, Alex W

    2014-07-01

    The study investigated the effects of wearing two new designs of cotton glove on several hand performance capabilities and compared them against the effects of barehanded, single-layered and double cotton glove conditions when working with hand tools (screwdriver and pliers). The new glove designs were based on the findings of subjective hand discomfort assessments for this type of work and aimed to match the glove thickness to the localised pressure and sensitivity in different areas of the hand as well as to provide adequate dexterity for fine manipulative tasks. The results showed that the first prototype glove and the barehanded condition were comparable and provided better dexterity and higher handgrip strength than double thickness gloves. The results support the hypothesis that selective thickness in different areas of the hand could be applied by glove manufacturers to improve the glove design, so that it can protect the hands from the environment and at the same time allow optimal hand performance capabilities. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  2. Retained portion of latex glove during femoral nailing. Case report.

    Science.gov (United States)

    Sadat-Ali, M; Marwah, S; al-Habdan, I

    1996-11-01

    A case of retained glove during Kuntscher intramedullary nailing is described. An abscess around the glove could have lead to osteomyelitis. One need to be cautious feeling the top end of the nail while femoral nailing to avoid such a complication.

  3. Assessment of Protective Gloves for Use with Airfed Suits.

    Science.gov (United States)

    Millard, Claire E; Vaughan, Nicholas P

    2015-10-01

    Gloves are often needed for hand protection at work, but they can impair manual dexterity, especially if they are multilayered or ill-fitting. This article describes two studies of gloves to be worn with airfed suits (AFS) for nuclear decommissioning or containment level 4 (CL4) microbiological work. Both sets of workers wear multiple layers of gloves for protection and to accommodate decontamination procedures. Nuclear workers are also often required to wear cut-resistant gloves as an extra layer of protection. A total of 15 subjects volunteered to take part in manual dexterity testing of the different gloving systems. The subjects' hands were measured to ensure that the appropriate sized gloves were used. The gloves were tested with the subjects wearing the complete clothing ensembles appropriate to the work, using a combination of standard dexterity tests: the nine-hole peg test; a pin test adapted from the European Standard for protective gloves, the Purdue Pegboard test, and the Minnesota turning test. Specialized tests such as a hand tool test were used to test nuclear gloves, and laboratory-type manipulation tasks were used to test CL4 gloves. Subjective assessments of temperature sensation and skin wettedness were made before and after the dexterity tests of the nuclear gloves only. During all assessments, we made observations and questioned the subjects about ergonomic issues related to the clothing ensembles. Overall, the results show that the greater the thickness of the gloves and the number of layers the more the levels of manual dexterity performance are degraded. The nuclear cut-resistant gloves with the worst level of dexterity were stiff and inflexible and the subjects experienced problems picking up small items and bending their hands. The work also highlighted other factors that affect manual dexterity performance, including proper sizing, interactions with the other garments worn at the time, and the work equipment in use. In conclusion, when

  4. Production of surgical gloves from low extractable protein RVNRL

    Energy Technology Data Exchange (ETDEWEB)

    Marga, Utama; Yanti, S.; Made, Sumarti; Marsongko; Tita, Puspitasari; Dian, Iramani [Center for Research and Development of Isotopes and Radiation Technology, National Nuclear Energy Agency, Jakarta (Indonesia); Makuuchi, K. [EB System Cooperation, Takasaki, Gunma (Japan); Yoshii, F. [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment; Siswanto [Research Unit for Biotechnology of Estate Crop (Indonesia)

    2001-03-01

    Study on the production of surgical gloves from low extractable protein PVNRL (Radiation Vulcanization of Natural Rubber Latex) in home industry scale with normal butyl acrylate as sensitizer has been carried out. The variation of dipping speed, concentration of coagulant agent and selection of antioxidant for producing good quality of surgical gloves were evaluated. The water-extractable protein and PBS (Phosphate Buffer Saline) - extractable protein content, the physical and mechanical properties of gloves were measured. The results show that for producing a good quality of surgical gloves from low extractable protein RVNRL, the concentration of latex is 50% with calcium nitrate as coagulant agent between 15-20%. By using this condition the physical and mechanical properties of surgical gloves is required to ASTM standard such as tensile strength more than 24 MPa, PBS-extractable protein is around 41-68 ug/g and water-extractable protein contents is around 23-35 ug/g. (author)

  5. Pegasus Rocket Wing and PHYSX Glove Being Prepared for Stress Loads Testing

    Science.gov (United States)

    1997-01-01

    instrumentation systems for the glove. Other participating NASA centers included Ames Research Center, Mountain View, California; Goddard Space Flight Center, Greenbelt, Maryland; and Kennedy Space Center, Florida. Orbital Sciences Corporation, Dulles, Virginia, is the manufacturer of the Pegasus vehicle, while Vandenberg Air Force Base served as a pre-launch assembly facility for the launch that included the PHYSX experiment. NASA used data from Pegasus launches to obtain considerable data on aerodynamics. By conducting experiments in a piggyback mode on Pegasus, some critical and secondary design and development issues were addressed at hypersonic speeds. The vehicle was also used to develop hypersonic flight instrumentation and test techniques. NASA's B-52 carrier-launch vehicle was used to get the Pegasus airborne during six launches from 1990 to 1994. Thereafter, an Orbital Sciences L-1011 aircraft launched the Pegasus. The Pegasus launch vehicle itself has a 400- to 600-pound payload capacity in a 61-cubic-foot payload space at the front of the vehicle. The vehicle is capable of placing a payload into low earth orbit. This vehicle is 49 feet long and 50 inches in diameter. It has a wing span of 22 feet. (There is also a Pegasus XL vehicle that was introduced in 1994. Dryden has never launched one of these vehicles, but they have greater thrust and are 56 feet long.)

  6. Indications and the requirements for single-use medical gloves

    Science.gov (United States)

    Kramer, Axel; Assadian, Ojan

    2016-01-01

    Aim: While the requirements for single-use gloves for staff protection are clearly defined, the conventional medical differentiation between “sterile surgical gloves” used during surgical procedures and “single-use medical gloves” used in non-sterile medical areas does not adequately define the different requirements in these two areas of use. Sterilization of single-use medical gloves is not performed if sterility is not required; thus, another terminology must be found to identify the safety quality of non-sterile single-use medical gloves. Therefore, the labeling of such gloves should reflect this situation, by introducing the term “pathogen-free” single-use glove. The hygienic safety of such a glove would be attainable by ensuring aseptic manufacturing conditions during manufacturing and control of pathogen load of batch controls after fabrication. Proposed recommendation: Because single-use gloves employed in non-sterile areas come into contact not only with intact skin but also with mucous membranes, no potential pathogens should be detectable in 100 mL of rinse sample. In order to declare such gloves as pathogen-free we suggest absence of the indicator species S. aureus and E. coli. In addition, the total CFU count should be evaluated, since a high load indicates lack of optimal hygiene during the manufacturing process. Based on the requirements for potable water and findings obtained from investigations of the bacterial load of such gloves after manufacturing, the here suggested limit for the total bacterial count of glove seems realistic. PMID:26816673

  7. Laryngeal (Voice Box) Cancer

    Science.gov (United States)

    ... ENTCareers Marketplace Find an ENT Doctor Near You Voice Box (Laryngeal) Cancer Voice Box (Laryngeal) Cancer Patient Health Information News media ... laryngeal cancer can be severe with respect to voice, breathing, or swallowing. It is fundamentally a preventable ...

  8. Operation of post-irradiation examination facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, E. G.; Jeon, Y. B.; Ku, D. S.

    1996-12-01

    In 1996, the post-irradiation examination(PIE) of nuclear fuels was performed as follows. It has been searched for the caution of defection of defected fuel rods of Youngkwang-4 reactor through NDT and metallographic examination that had been required by KEPCO. And in-pool inspection of Kori-1 spent fuel assembly(FO2) was carried out. HVAC system and pool water treatment system have been operated to maintain the facility safely, and electric power supply system was checked and maintained for the normal and steady supply electric power to the facility. Image processing software was developed for measurement of defection of spent fuel rods. Besides, a radiation shielding glove box was fabricated and a hot cell compressor for volume reduction of radioactive materials was fabricated and installed in hot cell. Safeguards of nuclear materials were implemented in strict accordance with the relevant Korean rules and regulations as well as the international non-proliferation regime. Also the IAEA inspection was carried out on the quarterly basis. (author). 31 tabs., 71 figs., 4 refs.

  9. Decommissioning of the Risoe Hot Cell facility

    International Nuclear Information System (INIS)

    Carlsen, H.

    1991-02-01

    The Hot Cell facility at Risoe has been in active use since 1964. During the years several types of nuclear fuels have been handled and examined: test reactor fuel pins from the Danish reactor DR3, the Norwegian Halden reactor, etc; power reactor fuel pins from several foreign reactors, including plutonium enriched pins; HTGR fuel from the Dragon reactor. All kinds of physical and chemical non-destructive and destructive post irradiation examinations have been performed. Besides, different radiotherapy sources have been produced, mainly cobalt sources. The general object of the decommissioning programme for the Hot Cell facility was to obtain a safe condition for the total building that does not require the special safety provisions. The hot cell building will be usable for other purposes after decommissioning. The facilicy comprised six concrete cells, lead cells, glove boxes, a shielded unit for temporary storage of waste, frogman area, decontamination areas, workshops, various installations of importance for safe operation of the plant, offices, etc. The tasks comprised e.g. removal of all irradiated fuel items, removal of other radioactive items, removal of contaminated equipment, and decontamination of all the cells and rooms. The goal was to decontaminate all the concrete cells to a degree where no loose contamination exists in the cells, and where the radiation level is so low, that total removal of the cell structures can be done at any time in the future without significant dose commitments. (AB)

  10. Shaping 3-D boxes

    DEFF Research Database (Denmark)

    Stenholt, Rasmus; Madsen, Claus B.

    2011-01-01

    Enabling users to shape 3-D boxes in immersive virtual environments is a non-trivial problem. In this paper, a new family of techniques for creating rectangular boxes of arbitrary position, orientation, and size is presented and evaluated. These new techniques are based solely on position data......F) docking experiment against an existing technique, which requires the user to perform the rotation and scaling of the box explicitly. The precision of the users' box construction is evaluated by a novel error metric measuring the difference between two boxes. The results of the experiment strongly indicate...

  11. Evaluation of the efficacy of antibacterial medical gloves in the ICU setting.

    Science.gov (United States)

    Kahar Bador, M; Rai, V; Yusof, M Y; Kwong, W K; Assadian, O

    2015-07-01

    Inappropriate use of medical gloves may support microbial transmission. New strategies could increase the safety of medical gloves without the risk of patient and surface contamination. To compare the efficacy of synthetic antibacterial nitrile medical gloves coated with polyhexamethylen-biguanid hydrochloride (PHMB) on the external surface with identical non-antibacterial medical gloves in reducing glove contamination after common patient care measures in an intensive care unit (ICU) setting. ICU staff wore either standard or antibacterial gloves during patient care activities. The number of bacteria on gloves was measured semi-quantitatively immediately after the performance of four clinical activities. There was a significant difference in mean bacterial growth [colony-forming units (cfu)] between control gloves and antibacterial gloves {60 [standard deviation (SD) 23] vs 16 (SD 23) cfu/glove imprint, P gloves had significantly less bacterial contamination compared with the control gloves (P = 0.011 and gloves showed lower bacterial contamination after changing linen compared with control gloves, the difference was not significant (P = 0.311). This study showed that use of antibacterial medical gloves significantly reduced bacterial contamination after typical patient care activities in 57% of the investigated clinical activities (P gloves may support reduction of cross-contamination in the ICU setting. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  12. 76 FR 6683 - Information Related to Risks and Benefits of Powdered Gloves; Request for Comments

    Science.gov (United States)

    2011-02-07

    ... Drug Administration Information Related to Risks and Benefits of Powdered Gloves; Request for Comments... Gloves and Patient Examination Gloves That Use Powder; Notices #0;#0;Federal Register / Vol. 76 , No. 25... Gloves; Request for Comments AGENCY: Food and Drug Administration, HHS. ACTION: Notice; request for...

  13. Glove leakage rates as a function of latex content and brand: caveat emptor.

    Science.gov (United States)

    Muto, C A; Sistrom, M G; Strain, B A; Farr, B M

    2000-08-01

    That water leakage rates and protection against blood-borne pathogens should not vary as a function of latex content among Food and Drug Administration-approved gloves, allowing avoidance of unnecessary latex exposure. Eighteen different glove types were purchased and tested using the American Society for Testing Methods Standard Test for Detecting Holes in medical gloves, which involves mounting the glove on a plastic tube, pouring a liter of tap water into the glove, and visually inspecting the glove initially and after 2 minutes. Half of the gloves were tested straight from the package and half after a standardized manipulation. A university hospital. Eleven sterile glove types (5 high latex content, 4 low latex content, and 2 nonlatex content), and 7 nonsterile examination glove types (2 high latex content, 2 low latex content, and 3 nonlatex content) were tested (total tested, 3720 gloves). Leakage rates were greater for examination than for surgical gloves (relative risk [RR], 1.41, 95% confidence interval [CI], 1.01-1.96), for manipulated than for unused gloves (RR, 2.89, 5% CI, 1.98-4.22), and for low latex content surgical gloves (RR, 2.58, 95% CI, 1.35-4.92) or nonlatex content surgical gloves (RR, 4.93, 95% CI, 2.35-10.32) than for high latex content surgical gloves. Significant differences were observed among low latex content surgical gloves (Pexposure to blood-borne pathogens, while others may not.

  14. Next Generation Life Support: High Performance EVA Glove

    Science.gov (United States)

    Walsh, Sarah K.

    2015-01-01

    The objectives of the High Performance EVA Glove task are to develop advanced EVA gloves for future human space exploration missions and generate corresponding standards by which progress may be quantitatively assessed. New technologies and manufacturing techniques will be incorporated into the new gloves to address finger and hand mobility, injury reduction and durability in nonpristine environments. Three prototypes will be developed, each focusing on different technological advances. A robotic assist glove will integrate a powered grasping system into the current EVA glove design to reduce astronaut hand fatigue and hand injuries. A mechanical counter pressure (MCP) glove will be developed to further explore the potential of MCP technology and assess its capability for countering the effects of vacuum or low pressure environments on the body by using compression fabrics or materials to apply the necessary pressure. A gas pressurized glove, incorporating new technologies, will be the most flight-like of the three prototypes. Advancements include the development and integration of aerogel insulation, damage sensing components, dust-repellant coatings, and dust tolerant bearings.

  15. Development and Test of Robotically Assisted Extravehicular Activity Gloves

    Science.gov (United States)

    Rogers, Jonathan M.; Peters, Benjamin J.; Laske, Evan A.; McBryan, Emily R.

    2017-01-01

    Over the past two years, the High Performance EVA Glove (HPEG) project under NASA's Space Technology Mission Directorate (STMD) funded an effort to develop an electromechanically-assisted space suit glove. The project was a collaboration between the Johnson Space Center's Software, Robotics, and Simulation Division and the Crew and Thermal Systems division. The project sought to combine finger actuator technology developed for Robonaut 2 with the softgoods from the ILC Phase VI EVA glove. The Space Suit RoboGlove (SSRG) uses a system of three linear actuators to pull synthetic tendons attached to the glove's fingers to augment flexion of the user's fingers. To detect the user's inputs, the system utilizes a combination of string potentiometers along the back of the fingers and force sensitive resistors integrated into the fingertips of the glove cover layer. This paper discusses the development process from initial concepts through two major phases of prototypes, and the results of initial human testing. Initial work on the project focused on creating a functioning proof of concept, designing the softgoods integration, and demonstrating augmented grip strength with the actuators. The second year of the project focused on upgrading the actuators, sensors, and software with the overall goal of creating a system that moves with the user's fingers in order to reduce fatigue associated with the operation of a pressurized glove system. This paper also discusses considerations for a flight system based on this prototype development and address where further work is required to mature the technology.

  16. Efficacy of protection by latex gloves during orthodontic therapy.

    Science.gov (United States)

    Doll, G M; Zentner, A; Balan, R; Sergl, H G

    2000-01-01

    The wearing of gloves during orthodontic or dental treatment is generally indicated for reasons of hygiene and protection against infection. This study was aimed at determining the extent and localization of perforations caused by the various orthodontic treatment techniques and interrupting the infection barrier. The impermeability was tested by means of a water retention test according to European standard EN 455, Part 1, performed on 1600 Centramed (Centramed, Koblenz), Tekmedic and SafeEx non-sterile disposable latex gloves (both by Safe Med, Switzerland) and Safe Gan latex gloves with an additional acrylate coating (also by Safe Med). The perforation rate in unused gloves was between 0.5% and 7.5%, rising on average to 11% with increasing use. 36% of the total number of lesions resulted from handling removable appliances, and 57% from handling fixed appliances, especially when replacing arch wires and elastics. Most lesions were in the thumb, index finger and palm region. Only 18% of the defects were noticed by the dentists themselves. The gloves worn by beginners in their first year of postgraduate orthodontic training had about twice as many defects as those worn by qualified orthodontists. When patients with an increased risk of infection are to be treated, additional hand disinfection measures should be taken and 2 pairs of gloves worn in view of the relatively unreliable protection offered by commercially available latex gloves.

  17. Atomics International fuel fabrication facility and low enrichment program. Part 1

    International Nuclear Information System (INIS)

    Moss, T.A.

    1993-01-01

    The Al facility is approximately 30,000 square feet in area and consists of four general areas. One area is devoted to the production of UAl x powder. It consists of a series of arc melting furnaces, crushing lines, glove boxes, and compacting presses. The second area is used for the rolling of fuel plates. The third area is used for the machining of the plates to final size and also the machining of the fuel elements. In the fourth area the fuel plates are swaged into assemblies, and all welding and inspection operations are performed. As part of the lower enrichment program we are scheduled to put a second UAl x powder line into operation and we have had to expand some of our storage area

  18. Thinking Inside the Box

    International Nuclear Information System (INIS)

    Boeheim, Charles T.

    2007-01-01

    In early 2007, SLAC was faced with a shortage of both electrical power and cooling in the main computer building, at the same time that the BaBar collaboration needed a new cluster of 250 batch machines installed. A number of different options were explored for the expansion. Provision of additional electrical power to the building was estimated to take one to two years, and cost several million dollars; additional cooling was even worse. Space in a Silicon Valley co-location facilities was reasonable on a one-year timescale, but broke even in costs by the end of three years, and were more expensive after that. There were also unresolved questions about the affects of additional latency from an offsite compute cluster to the onsite disk servers. The option of converting existing experimental hall space into computer space was estimated at one year, with uncertain availability. An option to aggressively replace several existing clusters with more power-efficient equipment was studied closely, but was disruptive to continued operations, expensive, and didn't provide any additional headroom. Finally, the installation of a Sun Project Blackbox (PBB) unit was selected as providing the capacity on a timescale of six months for a reasonable cost with minimal disruption to service. SLAC obtained and installed a beta unit and have been running it in production since September 2007. The experiences described are with the Early Access version of the PBB. The production version of the box has engineering changes based in part on our experiences

  19. Energy evaluation of protection effectiveness of anti-vibration gloves.

    Science.gov (United States)

    Hermann, Tomasz; Dobry, Marian Witalis

    2017-09-01

    This article describes an energy method of assessing protection effectiveness of anti-vibration gloves on the human dynamic structure. The study uses dynamic models of the human and the glove specified in Standard No. ISO 10068:2012. The physical models of human-tool systems were developed by combining human physical models with a power tool model. The combined human-tool models were then transformed into mathematical models from which energy models were finally derived. Comparative energy analysis was conducted in the domain of rms powers. The energy models of the human-tool systems were solved using numerical simulation implemented in the MATLAB/Simulink environment. The simulation procedure demonstrated the effectiveness of the anti-vibration glove as a method of protecting human operators of hand-held power tools against vibration. The desirable effect is achieved by lowering the flow of energy in the human-tool system when the anti-vibration glove is employed.

  20. Permeation of aromatic solvent mixtures through nitrile protective gloves.

    Science.gov (United States)

    Chao, Keh-Ping; Hsu, Ya-Ping; Chen, Su-Yi

    2008-05-30

    The permeation of binary and ternary mixtures of benzene, toluene, ethyl benzene and p-xylene through nitrile gloves were investigated using the ASTM F739 test cell. The more slowly permeating component of a mixture was accelerated to have a shorter breakthrough time than its pure form. The larger differences in solubility parameter between a solvent mixture and glove resulted in a lower permeation rate. Solubility parameter theory provides a potential approach to interpret the changes of permeation properties for BTEX mixtures through nitrile gloves. Using a one-dimensional diffusion model based on Fick's law, the permeation concentrations of ASTM F739 experiments were appropriately simulated by the estimated diffusion coefficient and solubility. This study will be a fundamental work for the risk assessment of the potential dermal exposure of workers wearing protective gloves.

  1. Use of a pneumatic glove for hand rehabilitation following stroke.

    Science.gov (United States)

    Connelly, Lauri; Stoykov, Mary Ellen; Jia, Yicheng; Toro, Maria L; Kenyon, Robert V; Kamper, Derek G

    2009-01-01

    Hand impairment is common following stroke and is often resistant to traditional therapy methods. Successful interventions have stressed the importance of repeated practice to facilitate rehabilitation. Thus, we have developed a servo-controlled glove to assist extension of individual digits to promote practice of grasp-and-release movements with the hand. This glove, the PneuGlove, permits free movement of the arm throughout its workspace. A novel immersive virtual reality environment was created for training movement in conjunction with the device. Seven stroke survivors with chronic hand impairment participated in 18 training sessions with the PneuGlove over 6 weeks. Overall, subjects displayed a significant 6-point improvement in the upper extremity score on the Fugl-Meyer assessment and this increase was maintained at the evaluation held one month after conclusion of all training (p training of hand movements after stroke.

  2. Glove Changing When Handling Money: Observational and Microbiological Analysis.

    Science.gov (United States)

    Basch, Corey H; Wahrman, Miryam Z; Shah, Jay; Guerra, Laura A; MacDonald, Zerlina; Marte, Myladys; Basch, Charles E

    2016-04-01

    The purpose of this study was to determine the rate of glove changing by mobile food vendors after monetary transactions, and the presence of bacterial contamination on a sample of dollar bills obtained from 25 food vendors near five hospitals in Manhattan, New York City. During 495 monetary transactions observed there were only seven glove changes performed by the workers. Eleven of 34 food workers wore no gloves at all while handling money and food. Nineteen of 25 one-dollar bills collected (76 %) had 400 to 42,000 total bacterial colony-forming units. Colonies were of varied morphology and size. Of these 19 samples, 13 were selected (based on level of growth), and tested for the presence of coliform bacteria, which was found in 10 of the 13 samples. Effective strategies to monitor and increase glove wearing and changing habits of mobile food vendors are needed to reduce risk of foodborne illness.

  3. Thermal comfort of dual-chamber ski gloves

    Science.gov (United States)

    Dotti, F.; Colonna, M.; Ferri, A.

    2017-10-01

    In this work, the special design of a pair of ski gloves has been assessed in terms of thermal comfort. The glove 2in1 Gore-Tex has a dual-chamber construction, with two possible wearing configurations: one called “grip” to maximize finger flexibility and one called “warm” to maximize thermal insulation in extremely cold conditions. The dual-chamber gloves has been compared with two regular ski gloves produced by the same company. An intermittent test on a treadmill was carried out in a climatic chamber: it was made of four intense activity phases, during which the volunteer ran at 9 km/h on a 5% slope for 4 minutes, spaced out by 5-min resting phases. Finger temperature measurements were compared with the thermal sensations expressed by two volunteers during the test.

  4. An Approach for Performance Assessments of Extravehicular Activity Gloves

    Science.gov (United States)

    Aitchison, Lindsay; Benosn, Elizabeth

    2014-01-01

    The Space Suit Assembly (SSA) Development Team at NASA Johnson Space Center has invested heavily in the advancement of rear-entry planetary exploration suit design but largely deferred development of extravehicular activity (EVA) glove designs, and accepted the risk of using the current flight gloves, Phase VI, for unique mission scenarios outside the Space Shuttle and International Space Station (ISS) Program realm of experience. However, as design reference missions mature, the risks of using heritage hardware have highlighted the need for developing robust new glove technologies. To address the technology gap, the NASA Game-Changing Technology group provided start-up funding for the High Performance EVA Glove (HPEG) Project in the spring of 2012. The overarching goal of the HPEG Project is to develop a robust glove design that increases human performance during EVA and creates pathway for future implementation of emergent technologies, with specific aims of increasing pressurized mobility to 60% of barehanded capability, increasing the durability by 100%, and decreasing the potential of gloves to cause injury during use. The HPEG Project focused initial efforts on identifying potential new technologies and benchmarking the performance of current state of the art gloves to identify trends in design and fit leading to establish standards and metrics against which emerging technologies can be assessed at both the component and assembly levels. The first of the benchmarking tests evaluated the quantitative mobility performance and subjective fit of two sets of prototype EVA gloves developed ILC Dover and David Clark Company as compared to the Phase VI. Both companies were asked to design and fabricate gloves to the same set of NASA provided hand measurements (which corresponded to a single size of Phase Vi glove) and focus their efforts on improving mobility in the metacarpal phalangeal and carpometacarpal joints. Four test subjects representing the design-to hand

  5. Benchmarking Evaluation Results for Prototype Extravehicular Activity Gloves

    Science.gov (United States)

    Aitchison, Lindsay; McFarland, Shane

    2012-01-01

    The Space Suit Assembly (SSA) Development Team at NASA Johnson Space Center has invested heavily in the advancement of rear-entry planetary exploration suit design but largely deferred development of extravehicular activity (EVA) glove designs, and accepted the risk of using the current flight gloves, Phase VI, for unique mission scenarios outside the Space Shuttle and International Space Station (ISS) Program realm of experience. However, as design reference missions mature, the risks of using heritage hardware have highlighted the need for developing robust new glove technologies. To address the technology gap, the NASA Game-Changing Technology group provided start-up funding for the High Performance EVA Glove (HPEG) Project in the spring of 2012. The overarching goal of the HPEG Project is to develop a robust glove design that increases human performance during EVA and creates pathway for future implementation of emergent technologies, with specific aims of increasing pressurized mobility to 60% of barehanded capability, increasing the durability by 100%, and decreasing the potential of gloves to cause injury during use. The HPEG Project focused initial efforts on identifying potential new technologies and benchmarking the performance of current state of the art gloves to identify trends in design and fit leading to establish standards and metrics against which emerging technologies can be assessed at both the component and assembly levels. The first of the benchmarking tests evaluated the quantitative mobility performance and subjective fit of four prototype gloves developed by Flagsuit LLC, Final Frontier Designs, LLC Dover, and David Clark Company as compared to the Phase VI. All of the companies were asked to design and fabricate gloves to the same set of NASA provided hand measurements (which corresponded to a single size of Phase Vi glove) and focus their efforts on improving mobility in the metacarpal phalangeal and carpometacarpal joints. Four test

  6. Mapping From an Instrumented Glove to a Robot Hand

    Science.gov (United States)

    Goza, Michael

    2005-01-01

    An algorithm has been developed to solve the problem of mapping from (1) a glove instrumented with joint-angle sensors to (2) an anthropomorphic robot hand. Such a mapping is needed to generate control signals to make the robot hand mimic the configuration of the hand of a human attempting to control the robot. The mapping problem is complicated by uncertainties in sensor locations caused by variations in sizes and shapes of hands and variations in the fit of the glove. The present mapping algorithm is robust in the face of these uncertainties, largely because it includes a calibration sub-algorithm that inherently adapts the mapping to the specific hand and glove, without need for measuring the hand and without regard for goodness of fit. The algorithm utilizes a forward-kinematics model of the glove derived from documentation provided by the manufacturer of the glove. In this case, forward-kinematics model signifies a mathematical model of the glove fingertip positions as functions of the sensor readings. More specifically, given the sensor readings, the forward-kinematics model calculates the glove fingertip positions in a Cartesian reference frame nominally attached to the palm. The algorithm also utilizes an inverse-kinematics model of the robot hand. In this case, inverse-kinematics model signifies a mathematical model of the robot finger-joint angles as functions of the robot fingertip positions. Again, more specifically, the inverse-kinematics model calculates the finger-joint commands needed to place the fingertips at specified positions in a Cartesian reference frame that is attached to the palm of the robot hand and that nominally corresponds to the Cartesian reference frame attached to the palm of the glove. Initially, because of the aforementioned uncertainties, the glove fingertip positions calculated by the forwardkinematics model in the glove Cartesian reference frame cannot be expected to match the robot fingertip positions in the robot

  7. CONTAMINATED PROCESS EQUIPMENT REMOVAL FOR THE DECOMMISSIONG AND DECONTAMINATION OF THE 232-Z CONTAMINATED WASTE RECOVERY PROCESS FACILITY AT THE PLUTONIUM FINISHING PLANT

    International Nuclear Information System (INIS)

    HOPKINS, A.M.; MINETTE, M.J.; KLOS, D.B.

    2007-01-01

    This paper describes the unique challenges encountered and subsequent resolutions to accomplish the deactivation and decontamination of a plutonium ash contaminated building. The 232-Z Contaminated Waste Recovery Process Facility at the Plutonium Finishing Plant was used to recover plutonium from process wastes such as rags, gloves, containers and other items by incinerating the items and dissolving the resulting ash. The incineration process resulted in a light-weight plutonium ash residue that was highly mobile in air. This light-weight ash coated the incinerator's process equipment, which included gloveboxes, blowers, filters, furnaces, ducts, and filter boxes. Significant airborne contamination (over 1 million derived air concentration hours [DAC]) was found in the scrubber cell of the facility. Over 1300 grams of plutonium held up in the process equipment and attached to the walls had to be removed, packaged and disposed. This ash had to be removed before demolition of the building could take place

  8. The Design and Construction of the Advanced Mixed Waste Treatment Facility

    Energy Technology Data Exchange (ETDEWEB)

    Harrop, G.

    2003-02-27

    The Advanced Mixed Treatment Project (AMWTP) privatized contract was awarded to BNFL Inc. in December 1996 and construction of the main facility commenced in August 2000. The purpose of the advanced mixed waste treatment facility is to safely treat plutonium contaminated waste, currently stored in drums and boxes, for final disposal at the Waste Isolation Pilot Plant (WIPP). The plant is being built at the Idaho National Engineering and Environmental Laboratory. Construction was completed in 28 months, to satisfy the Settlement Agreement milestone of December 2002. Commissioning of the related retrieval and characterization facilities is currently underway. The first shipment of pre-characterized waste is scheduled for March 2003, with AMWTP characterized and certified waste shipments from June 2003. To accommodate these challenging delivery targets BNFL adopted a systematic and focused construction program that included the use of a temporary structure to allow winter working, proven design and engineering principles and international procurement policies to help achieve quality and schedule. The technology involved in achieving the AMWTP functional requirements is primarily based upon a BNFL established pedigree of plant and equipment; applied in a manner that suits the process and waste. This technology includes the use of remotely controlled floor mounted and overhead power manipulators, a high power shredder and a 2000-ton force supercompactor with the attendant glove box suite, interconnections and automated material handling. The characterization equipment includes real-time radiography (RTR) units, drum and box assay measurement systems, drum head space gas sampling / analysis and drum venting, drum coring and sampling capabilities. The project adopted a particularly stringent and intensive pre-installation testing philosophy to ensure that equipment would work safely and reliably at the required throughput. This testing included the complete off site

  9. Minimizing surgical skin incision scars with a latex surgical glove.

    Science.gov (United States)

    Han, So-Eun; Ryoo, Suk-Tae; Lim, So Young; Pyon, Jai-Kyung; Bang, Sa-Ik; Oh, Kap-Sung; Mun, Goo-Hyun

    2013-04-01

    The current trend in minimally invasive surgery is to make a small surgical incision. However, the excessive tensile stress applied by the retractors to the skin surrounding the incision often results in a long wound healing time and extensive scarring. To minimize these types of wound problems, the authors evaluated a simple and cost-effective method to minimize surgical incision scars based on the use of a latex surgical glove. The tunnel-shaped part of a powder-free latex surgical glove was applied to the incision and the dissection plane. It was fixed to the full layer of the dissection plane with sutures. The glove on the skin surface then was sealed with Ioban (3 M Health Care, St. Paul, MN, USA) to prevent movement. The operation proceeded as usual, with the retractor running through the tunnel of the latex glove. It was possible to complete the operation without any disturbance of the visual field by the surgical glove, and the glove was neither torn nor separated by the retractors. The retractors caused traction and friction during the operation, but the extent of damage to the postoperative skin incision margin was remarkably less than when the operation was performed without a glove. This simple and cost-effective method is based on the use of a latex surgical glove to protect the surgical skin incision site and improve the appearance of the postoperative scar. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  10. Empirical Evidence of Risk and Performance: Top Glove Corporation Berhad

    OpenAIRE

    lim, yu zhi

    2017-01-01

    The purpose of this study is desired to examine the profitability performance of Top Glove Corporation Berhad with some risk factors (liquidity risk, operating risk) and macroeconomic factors. This study was according to the annual report data of Top Glove from year 2011 to year 2015. It shows that there are negative relationship between the company’s profitability and the operating ratio. By using the IBM SPSS Statistics software and add some measurement such as GDP, inflation rate, asset si...

  11. Influence of material properties on gloves' bacterial barrier efficacy in the presence of microperforation.

    Science.gov (United States)

    Bardorf, Michael Hermann; Jäger, Bernd; Boeckmans, Eric; Kramer, Axel; Assadian, Ojan

    2016-12-01

    Medical examination gloves and surgical gloves protect the wearer directly and the patient indirectly from the risk of contamination. Because of concerns related to latex allergy, an increasing trend toward the use of synthetic gloves made of materials other than latex is observable. However, currently it is unknown if the physical properties of different materials may influence bacterial passage in case of a glove puncture. We examined 9 different medical examination gloves from various manufacturers made of nitrile (n = 4), latex (n = 3), or neoprene (n = 2). Additionally, 1 latex surgical glove each with and without antibacterial chlorhexidine gluconate coating and 1 synthetic surgical glove made of thermoplastic elastomer were included in the experiments. The studied materials were perforated following a standardized procedure, and direct bacterial passage was measured under dynamic conditions. Glove elasticity at 1 cm up to 2.5 cm elongation was measured following EN 455-2. Nitrile gloves demonstrated higher material stiffness compared with latex gloves. Medical examination gloves made of nitrile and neoprene showed a 10-fold higher bacterial passage through a standardized puncture compared with latex gloves. All surgical gloves showed a lower bacterial passage compared with the tested examination gloves. Bacterial passage through punctures is correlated with the stiffness or elasticity of the glove material. Therefore, gloves made of latex may have an increased protective effect in case of a glove breach. Whenever gloves are purchased and selected, a risk-benefit assessment should be conducted, balancing the risk of allergy against the degree of required protection in case of a glove puncture. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  12. Protective gloves on manual sugar cane cutting are really effective?

    Science.gov (United States)

    Abrahão, R F; Gonzaga, M C; Braunbeck, O A

    2012-01-01

    Problems related to the use of personal protective equipment (PPE), specially the use of protective gloves for the manual sugar cane cutting, motivated this research, made possible by a tripartite negotiation involving the Ministry of Labor, the Union of Rural Workers and the Employer's Association of sugarcane agribusiness. The main objective was to evaluate, from an ergonomics perspective, the impact of use of the gloves during the manual cane sugar cutting, raising questions on safety, effectiveness and comfort. The research was carried in a sugarcane industry of São Paulo for two seasons involving 47 workers who made a qualitative analysis of acceptance of four models of protective gloves. The methodology included the use of semi-structured interviews, questionnaires and field observations and the experimental determination of the coefficient of static friction developed between the gloves and the surfaces of the machete handle. The main results indicate the general inadequacy of the gloves currently used forcing the employees to improvise. Workers found the glove of leather and nylon scraping the best reported for comfort in use. The overall results highlight the problem of detachment of test standards for the manufacture of PPE, ignoring users and the activity to be performed.

  13. Shielding ability of lead loaded radiation resistant gloves

    International Nuclear Information System (INIS)

    Kawano, Takao; Ebihara, Hiroshi

    1990-01-01

    The shielding ability of radiation resistant gloves were examined. The gloves are made of lead loaded (as PbO 2 ) polyvinyl chloride resin and are about 0.4 mm of thickness (70 mg/cm 2 ). Eleven test pieces were sampled from each of three gloves (total were thirty three) and the transmission rates for radiations (X-ray or γ-ray) through the test pieces were measured with radiation sources, 99m Tc, 57 Co, 133 Ba, 133 Xe and 241 Am. The differences of the transmission rate for radiations by the positions of the gloves were smaller than 15%, and the differences by three gloves were smaller than 5% in the case of 60 keV and 141 keV radiations. The average transmission rates for radiations in thirty three test pieces were about 40% for 30 keV radiation, about 90% for 80 keV and 140 keV radiations. The shielding characteristic of the gloves could be equivalent to about 0.026 mm thick lead plate. (author)

  14. Assessment of skin exposure to N,N-dimethylformamide and methyl ethylketone through chemical protective gloves and decontamination of gloves for reuse purposes.

    Science.gov (United States)

    Chao, Keh-Ping; Wang, Ping; Chen, Chen-Peng; Tang, Ping-Yu

    2011-02-15

    N,N-dimethylformamide (DMF) and methyl ethylketone (MEK) are the hazardous chemicals commonly used in the synthetic leather industries. Although chemical protective gloves provide adequate skin exposure protection to workers in these industries, there is currently no clear guideline or understanding with regard to the use duration of these gloves. In this study, the permeation of DMF/MEK mixture through neoprene gloves and the desorption of chemicals from contaminated gloves were conducted using the ASTM F739 cell. The acceptable use duration time of the gloves against DMF/MEK permeation was estimated by assuming a critical body burden of chemical exposure as a result of dermal absorption. In a re-exposure cycle of 5 days, decontamination of the gloves by aeration at 25°C was found to be inadequate in a reduction of breakthrough time as compared to a new unexposed glove. However, decontamination of the gloves by heating at 70 or 100°C showed that the protective coefficient of the exposed gloves had similar levels of resistance to DMF/MEK as that of new gloves. Implications of this study include an understanding of the use duration of neoprene gloves and proper decontamination of chemical protective gloves for reuse. Copyright © 2010 Elsevier B.V. All rights reserved.

  15. Operation of post-irradiation examination facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Ka; Park, Kwang Joon; Jeon, Yong Bum [and others] [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-02-01

    In 1995, the post-irradiation examination (PIE) of nuclear fuels was performed as follows. The relation between burnup and top nozzle spring force of fuel assembly was obtained by measuring the holddown spring force on the Kori-1 reactor fuel assemblies. The resonance ultrasonic test for inspection of defect and moisture in fuel rod was carried out on fuel rods of C15 and J14 assemblies, and the change of fuel rod condition by storing in pool has been analyzed on the intentionally defected fuel rods (ID-C and ID-L) as well as intact fuel rod (1-2) by NDT in ht cell. The oxide layer thickness on cladding surface of J44-L12 fuel rod was measured by NDT method and metallography to reveal the oxidation as a function of temperature in the fuel rod, and the burnup of J44 fuel assembly was measured by chemical analysis. HVAC system and pool water treatment system of the PIE facility were continuously operated for air filtration and water purification. The monitoring of radiation and pool water in PIE facility has been carried out to maintain the facility safety, and electric power supply system was checked and maintained to supply the electric power to the facility normally. The developed measurement techniques of oxide layer thickness on fuel rod cladding and holddown spring force of top nozzle in fuel assembly were applied to examine the nuclear fuels. Besides, a radiation shielding glove box was designed and a hot cell compressor for volume reduction of radioactive materials was fabricated. 19 tabs., 38 figs., 7 refs. (Author) .new.

  16. Catalyst study for the decontamination of glove-box atmospheres containing tritium at MPC levels

    International Nuclear Information System (INIS)

    Chobot, J.; Montel, J.; Sannier, J.

    1988-01-01

    The BEATRICE loop was designed for studying the conversion of tritium at very low activity levels using catalytic oxidation followed by water trapping. The purpose is to study kinetic parameters required for the design of the NET tritium cleanup system with the two main objectives to operate without isotopic swamping and to determine the ability of efficient conversion at room temperature. From experiments carried out between 20 and 250 0 C it is concluded that two palladium/alumina and platinum/alumina catalysts are very efficient in removing tritium from contaminated gas mixtures down to a few MPC levels without isotopic swamping and even at room temperature. However at room temperature, in relation to tritium species trapped on the catalyst surface a progressive deactivation with time occurs. This phenomenon may be a concern for process efficiency and tritium inventory and regeneration conditions have to be determined in order to demonstrate industrial feasibility of operating at room temperature

  17. Design and test about de tritium system to filling tritium glove box

    International Nuclear Information System (INIS)

    Lei, Jiarong; Du, Yang; Yang, Yong

    2008-01-01

    In order to deal tritium permeated from inflating tritium system at the scene of inflating tritium, dealing waste tritium gas system was designed according to demand and action of dealing waste tritium gas from inflating tritium, and the data of character and volume about appliance of catalyst reaction and drying agent was calculated. Through the test at the scene of inflating tritium, it is result that dealing waste tritium gas system's efficiency reaches above 85% average in circulatory system, so that it can be used in practice extensively. (author)

  18. Catalyst study for the decontamination of glove-boxe atmospheres containing tritium at MPC levels

    International Nuclear Information System (INIS)

    Chabot, J.; Montel, J.; Sannier, J.

    1988-01-01

    The BEATRICE loop was designed for studying the conversion of tritium at very low activity levels using catalytic oxidation followed by water trapping. The purpose is to study kinetic parameters required for the design of the NET tritium clean-up system with the two main objectives to operate without isotopic swamping and to determine the ability of efficient conversion at room temperature. From experiments carried out between 20 and 250 0 C it is concluded that two palladium/alumina and platinum/alumina catalysts are very efficient in removing tritium from contaminated gas mixtures down to a few MPC levels without isotopic swamping and even at room temperature. However at room temperature, in relation to tritium species trapped on the catalyst surface a progressive deactivation with time occurs. This phenomenon may be a concern for process efficiency and tritium inventory and best regeneration conditions have to be determined in order to demonstrate industrial feasibility of operating at room temperature

  19. Lifecycle baseline summary for ADS 6504IS isotopes facilities Deactivation Project at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1995-08-01

    The scope of this Activity Data Sheet (ADS) is to provide a detailed plan for the Isotopes Facilities Deactivation Project (IFDP) at the Oak Ridge National Laboratory (ORNL). This project places the former isotopes production facilities in a safe, stable, and environmentally sound condition suitable for an extended period of minimum surveillance and maintenance (S ampersand M) until the facilities are included in the Decontamination and Decommissioning (D ampersand D) Program. The facilities included within this deactivation project are Buildings 3026-C, 3026-D, 3028, 3029, 3038-AHF, 3038-E, 3038-M, 3047, 3517, 7025, and the Center Circle Facilities (Buildings 3030, 3031, 3032, 3033, 3033-A, 3034, and 3118). The scope of deactivation identified in this Baseline Report include surveillance and maintenance activities for each facility, engineering, contamination control and structural stabilization of each facility, radioluminescent (RL) light removal in Building 3026, re-roofing Buildings 3030, 3118, and 3031, Hot Cells Cleanup in Buildings 3047 and 3517, Yttrium (Y) Cell and Barricades Cleanup in Building 3038, Glove Boxes ampersand Hoods Removal in Buildings 3038 and 3047, and Inventory Transfer in Building 3517. For a detailed description of activities within this Work Breakdown Structure (WBS) element, see the Level 6 and Level 7 Element Definitions in Section 3.2 of this report

  20. Will medical examination gloves protect rescuers from defibrillation voltages during hands-on defibrillation?

    Science.gov (United States)

    Sullivan, Joseph L; Chapman, Fred W

    2012-12-01

    Continuing compressions during a defibrillation shock has been proposed as a method of reducing pauses in cardiopulmonary resuscitation (CPR) but the safety of this procedure is unproven. The medical examination gloves worn by rescuers play an important role in protecting the rescuer yet the electrical characteristics of these gloves are unknown. This study examined the response of medical examination gloves to defibrillation voltages. Part 1 of this study measured voltage-current curves for a small sample (8) of gloves. Part 2 tested more gloves (460) to determine the voltage required to produce a specific amount of current flow. Gloves were tested at two current levels: 0.1 mA and 10 mA. Testing included four glove materials (chloroprene, latex, nitrile, and vinyl) in a single layer and double-gloved. All gloves tested in part 1 allowed little current to flow (gloves and 93 of 120 (77%) double gloves allowed at least 0.1 mA of current flow at voltages within the external defibrillation voltage range. Also, 6 of 80 (7.5%) single gloves and 5 of 80 (6.2%) double gloves allowed over 10 mA. Few of the gloves tested limited the current to levels proven to be safe. A lack of sensation during hands-on defibrillation does not guarantee that a safety margin exists. As such, we encourage rescuers to minimize rather than eliminate the pause in compressions for defibrillation. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  1. Thinking outside the Box

    Science.gov (United States)

    Fanshawe, Simon; Sriskandarajah, Dhananjayan

    2010-01-01

    Britain is not only more diverse than ever before, but that diversity itself is growing more diverse. Britain's simplistic "tick-box" approach to identity is in danger of inhibiting the very equality it seeks to promote. To question the tick-box is not to accuse local authorities of "political correctness gone mad". The notion…

  2. ALUMINUM BOX BUNDLING PRESS

    Directory of Open Access Journals (Sweden)

    Iosif DUMITRESCU

    2015-05-01

    Full Text Available In municipal solid waste, aluminum is the main nonferrous metal, approximately 80- 85% of the total nonferrous metals. The income per ton gained from aluminum recuperation is 20 times higher than from glass, steel boxes or paper recuperation. The object of this paper is the design of a 300 kN press for aluminum box bundling.

  3. Changes in chemical permeation of disposable latex, nitrile, and vinyl gloves exposed to simulated movement.

    Science.gov (United States)

    Phalen, Robert N; Le, Thi; Wong, Weng Kee

    2014-01-01

    Glove movement can affect chemical permeation of organic compounds through polymer glove products. However, conflicting reports make it difficult to compare the effects of movement on chemical permeation through commonly available glove types. The aim of this study was to evaluate the effect of movement on chemical permeation of an organic solvent through disposable latex, nitrile, and vinyl gloves. Simulated whole-glove permeation testing was conducted using ethyl alcohol and a previously designed permeation test system. With exposure to movement, a significant decrease (p ≤ 0.001) in breakthrough time (BT) was observed for the latex (-23%) and nitrile gloves (-31%). With exposure to movement, only the nitrile glove exhibited a significant increase (p ≤ 0.001) in steady-state permeation rate (+47%) and cumulative permeation at 30 min (+111%). Even though the nitrile glove provided optimum chemical resistance against ethyl alcohol, it was most affected by movement. With exposure to movement, the latex glove was an equivalent option for overall worker protection, because it was less affected by movement and the permeation rate was lower than that of the nitrile glove. In contrast, the vinyl glove was the least affected by movement, but did not provide adequate chemical resistance to ethyl alcohol in comparison with the nitrile and latex gloves. Glove selection should take movement and polymer type into account. Some glove polymer types are less affected by movement, most notably the latex glove in this test. With nitrile gloves, at least a factor of three should be used when attempting to assign a protection factor when repetitive hand motions are anticipated. Ultimately, the latex gloves outperformed nitrile and vinyl in these tests, which evaluated the effect of movement on chemical permeation. Future research should aim to resolve some of the observed discrepancies in test results with latex and vinyl gloves.

  4. The influence of hydrogen peroxide on the permeability of protective gloves to resorcinol in hairdressing.

    Science.gov (United States)

    Lind, Marie-Louise; Johnsson, Stina; Lidén, Carola; Meding, Birgitta; Boman, Anders

    2015-01-01

    Hairdressers are exposed to hair dye chemicals, for example resorcinol and hydrogen peroxide. Adequate skin protection is an important preventive measure against occupational skin disease. To examine whether hydrogen peroxide may cause deterioration of protective gloves. Permeation of resorcinol through gloves of polyvinylchloride (PVC) (n = 8), natural rubber latex (NRL) (n = 5) and nitrile rubber (NR) (n = 5) was studied in a two-compartment cell, with resorcinol as an indicator for hair dyes. The amount of resorcinol that had permeated was analysed with a high-performance liquid chromatography instrument. Cumulative breakthrough time and permeation rate were compared for hydrogen peroxide-pretreated and untreated gloves. The cumulative breakthrough time was > 1 hr but gloves. Pretreatment of PVC gloves resulted in a slightly decreased breakthrough time, and pretreatment of NRL gloves decreased the permeation rate. No change was recorded in NR gloves. Treatment with hydrogen peroxide had a minor effect on permeation in the tested gloves. NR gloves provided the best protection. However, taking the allergy risk of rubber gloves into account, plastic gloves are recommended in hairdressing. PVC gloves may be used, but not for > 1 hr. Disposable gloves should never be reused, regardless of material. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Risk of surgical glove perforation in oral and maxillofacial surgery.

    Science.gov (United States)

    Kuroyanagi, N; Nagao, T; Sakuma, H; Miyachi, H; Ochiai, S; Kimura, Y; Fukano, H; Shimozato, K

    2012-08-01

    Oral and maxillofacial surgery, which involves several sharp instruments and fixation materials, is consistently at a high risk for cross-contamination due to perforated gloves, but it is unclear how often such perforations occur. This study aimed to address this issue. The frequency of the perforation of surgical gloves (n=1436) in 150 oral and maxillofacial surgeries including orthognathic surgery (n=45) was assessed by the hydroinsufflation technique. Orthognathic surgery had the highest perforation rate in at least 1 glove in 1 operation (91.1%), followed by cleft lip and palate surgery (55.0%), excision of oral soft tumour (54.5%) and dental implantation (50.0%). The perforation rate in scrub nurses was 63.4%, followed by 44.4% in surgeons and first assistants, and 16.3% in second assistants. The odds ratio for the perforation rate in orthognathic surgery versus other surgeries was 16.0 (95% confidence interval: 5.3-48.0). The protection rate offered by double gloving in orthognathic surgery was 95.2%. These results suggest that, regardless of the surgical duration and blood loss in all fields of surgery, orthognathic surgery must be categorized in the highest risk group for glove perforation, following gynaecological and open lung surgery, due to the involvement of sharp objects. Copyright © 2012 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  6. Functional Fit Evaluation to Determine Optimal Ease Requirements in Canadian Forces Chemical Protective Gloves

    National Research Council Canada - National Science Library

    Tremblay-Lutter, Julie

    1995-01-01

    A functional fit evaluation of the Canadian Forces (CF) chemical protective lightweight glove was undertaken in order to quantify the amount of ease required within the glove for optimal functional fit...

  7. Voice box (image)

    Science.gov (United States)

    The larynx, or voice box, is located in the neck and performs several important functions in the body. The larynx is involved in swallowing, breathing, and voice production. Sound is produced when the air which ...

  8. The POWHEG-BOX

    OpenAIRE

    Oleari, Carlo

    2010-01-01

    We review the key features of POWHEG, a method for interfacing parton-shower Monte Carlo generators to fixed next-to-leading order QCD computations. We describe a recently introduced framework, the POWHEG-BOX, that allows the automatic POWHEG implementation of any given NLO calculation. We present a few results for Higgs boson production via vector boson fusion and Z + 1 jet production, both processes available in the POWHEG-BOX.

  9. Boxes and Shelves

    OpenAIRE

    Hughes, Dean

    2008-01-01

    The Boxes and Shelves series from 2008 are are all made from the backing card from discarded writing pads. Boxes and Shelves extended my investigation of quotidian materials and their relationship to the origins of creative toil. Since 1996 my research has sought to identify and locate instances where the 'unmeasurable' meets the measurable. I have consistently employed a range of utilitarian materials such as bus seats, bus tickets, puddles, A4 writing paper, to present a series of 'problem ...

  10. Design and Dynamic Modeling of Flexible Rehabilitation Mechanical Glove

    Science.gov (United States)

    Lin, M. X.; Ma, G. Y.; Liu, F. Q.; Sun, Q. S.; Song, A. Q.

    2018-03-01

    Rehabilitation gloves are equipment that helps rehabilitation doctors perform finger rehabilitation training, which can greatly reduce the labour intensity of rehabilitation doctors and make more people receive finger rehabilitation training. In the light of the defects of the existing rehabilitation gloves such as complicated structure and stiff movement, a rehabilitation mechanical glove is designed, which provides driving force by using the air cylinder and adopts a rope-spring mechanism to ensure the flexibility of the movement. In order to fit the size of different hands, the bandage ring which can adjust size is used to make the mechanism fixed. In the interest of solve the complex problem of dynamic equation, dynamic simulation is carried out by using Adams to obtain the motion curve, which is easy to optimize the structure of ring position.

  11. Human-computer interface glove using flexible piezoelectric sensors

    Science.gov (United States)

    Cha, Youngsu; Seo, Jeonggyu; Kim, Jun-Sik; Park, Jung-Min

    2017-05-01

    In this note, we propose a human-computer interface glove based on flexible piezoelectric sensors. We select polyvinylidene fluoride as the piezoelectric material for the sensors because of advantages such as a steady piezoelectric characteristic and good flexibility. The sensors are installed in a fabric glove by means of pockets and Velcro bands. We detect changes in the angles of the finger joints from the outputs of the sensors, and use them for controlling a virtual hand that is utilized in virtual object manipulation. To assess the sensing ability of the piezoelectric sensors, we compare the processed angles from the sensor outputs with the real angles from a camera recoding. With good agreement between the processed and real angles, we successfully demonstrate the user interaction system with the virtual hand and interface glove based on the flexible piezoelectric sensors, for four hand motions: fist clenching, pinching, touching, and grasping.

  12. Tool-specific performance of vibration-reducing gloves for attenuating fingers-transmitted vibration

    Science.gov (United States)

    Welcome, Daniel E.; Dong, Ren G.; Xu, Xueyan S.; Warren, Christopher; McDowell, Thomas W.

    2016-01-01

    BACKGROUND Fingers-transmitted vibration can cause vibration-induced white finger. The effectiveness of vibration-reducing (VR) gloves for reducing hand transmitted vibration to the fingers has not been sufficiently examined. OBJECTIVE The objective of this study is to examine tool-specific performance of VR gloves for reducing finger-transmitted vibrations in three orthogonal directions (3D) from powered hand tools. METHODS A transfer function method was used to estimate the tool-specific effectiveness of four typical VR gloves. The transfer functions of the VR glove fingers in three directions were either measured in this study or during a previous study using a 3D laser vibrometer. More than seventy vibration spectra of various tools or machines were used in the estimations. RESULTS When assessed based on frequency-weighted acceleration, the gloves provided little vibration reduction. In some cases, the gloves amplified the vibration by more than 10%, especially the neoprene glove. However, the neoprene glove did the best when the assessment was based on unweighted acceleration. The neoprene glove was able to reduce the vibration by 10% or more of the unweighted vibration for 27 out of the 79 tools. If the dominant vibration of a tool handle or workpiece was in the shear direction relative to the fingers, as observed in the operation of needle scalers, hammer chisels, and bucking bars, the gloves did not reduce the vibration but increased it. CONCLUSIONS This study confirmed that the effectiveness for reducing vibration varied with the gloves and the vibration reduction of each glove depended on tool, vibration direction to the fingers, and finger location. VR gloves, including certified anti-vibration gloves do not provide much vibration reduction when judged based on frequency-weighted acceleration. However, some of the VR gloves can provide more than 10% reduction of the unweighted vibration for some tools or workpieces. Tools and gloves can be matched for

  13. PLAY HANDS PROTECTIVE GLOVES: TECHNICAL NOTE ON DESIGN AND CONCEPT.

    Science.gov (United States)

    Houston-Hicks, Michele; Lura, Derek J; Highsmith, M Jason

    2016-09-01

    Cerebral Palsy (CP) is the leading cause of childhood motor disability, with a global incidence of 1.6 to 2.5/1,000 live births. Approximately 23% of children with CP are dependent upon assistive technologies. Some children with developmental disabilities have self-injurious behaviors such as finger biting but also have therapeutic needs. The purpose of this technical note is to describe design considerations for a protective glove and finger covering that maintains finger dexterity for children who exhibit finger and hand chewing (dermatophagia) and require therapeutic range of motion and may benefit from sensory stimulation resulting from constant contact between glove and skin. Protecting Little and Adolescent Youth (PLAY) Hands are protective gloves for children with developmental disorders such as CP who injure themselves by biting their hands due to pain or sensory issues. PLAY Hands will be cosmetically appealing gloves that provide therapeutic warmth, tactile sensory feedback, range of motion for donning/ doffing, and protection to maximize function and quality of life for families of children with developmental disorders. The technology is either a per-finger protective orthosis or an entire glove solution designed from durable 3D-printed biodegradable/bioabsorbable materials such as thermoplastics. PLAY Hands represent a series of protective hand wear interventions in the areas of self-mutilating behavior, kinematics, and sensation. They will be made available in a range of protective iterations from single- or multi-digit finger orthoses to a basic glove design to a more structurally robust and protective iteration. To improve the quality of life for patients and caregivers, they are conceptualized to be cosmetically appealing, protective, and therapeutic.

  14. 77 FR 29718 - Self-Regulatory Organizations; BOX Options Exchange LLC; Notice of Filing and Immediate...

    Science.gov (United States)

    2012-05-18

    ... functionalities of the system are the same as are in effect under the rules of the BOX Group facility. The... the data available as proposed in order to improve market quality, to attract order flow, and to..., Rule 7130 sets forth that inbound orders on BOX are filtered prior to their entry on the BOX Book to...

  15. Effect of glove occlusion on the skin barrier

    DEFF Research Database (Denmark)

    Tiedemann, Daniel; Clausen, Maja Lisa; John, Swen Malthe

    2016-01-01

    that the negative effect of occlusion in itself is limited, and that only extensive and long-term occlusion will cause barrier impairment. However, studies investigating combined effect of occlusion and exposure to soaps/detergents indicate that occlusion significantly enhances the skin barrier damage caused...... of this study is to review the literature on the effects of glove occlusion on skin barrier function. The PubMed database was searched up to 1 February 2015 for articles on the association between glove occlusion and skin barrier function, including human studies only and in English. Only experimental studies...... by detergents/soaps in a dose-response fashion....

  16. A Glove for Tapping and Discrete 1D/2D Input

    Science.gov (United States)

    Miller, Sam A.; Smith, Andy; Bahram, Sina; SaintAmant, Robert

    2012-01-01

    This paper describes a glove with which users enter input by tapping fingertips with the thumb or by rubbing the thumb over the palmar surfaces of the middle and index fingers. The glove has been informally tested as the controller for two semi-autonomous robots in a a 3D simulation environment. A preliminary evaluation of the glove s performance is presented.

  17. 21 CFR 878.4480 - Absorbable powder for lubricating a surgeon's glove.

    Science.gov (United States)

    2010-04-01

    ... glove. 878.4480 Section 878.4480 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND....4480 Absorbable powder for lubricating a surgeon's glove. (a) Identification. Absorbable powder for lubricating a surgeon's glove is a powder made from corn starch that meets the specifications for absorbable...

  18. Atomics International fuel fabrication facility and low enrichment program [contributed by T.A. Moss, AI

    International Nuclear Information System (INIS)

    Moss, T.A.

    1993-01-01

    The AI facility is approximately 30,000 square feet in area and consists of four general areas. One area is devoted to the production of UAl x powder. It consists of a series of arc melting furnaces, crushing lines, glove boxes, and compacting presses. The second area is used for the rolling of fuel plates. The third area is used for the machining of the plates to final size and also the machining of the fuel elements. In the fourth area the fuel plates are swaged into assemblies, and all welding and inspection operations are performed. As part of the lower enrichment program we are scheduled to put a second UAl x powder line into operation and we have had to expand some of our storage area. Under the low enrichment program the AI fuel facility will be modified to accommodate a separate low enrichment Al x production line and compacting line. This facility modification should be done by the end of the fiscal year. We anticipate producing fuel with an enrichment slightly less than 20% We anticipate powder being available for plate production shortly after the facility is completed. Atomics International is scheduled to conduct plate LEU verification work using fully enriched material in the June-July time period, at which time we will investigate what level of uranium loadings we can go to using the current process. It is anticipated that 55 volume percent uranium compound in our fuel form can be achieved

  19. Standard Test Method for Gravimetric Determination of Nonvolatile Residue from Cleanroom Gloves

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers the determination of solvent extractable nonvolatile residue (NVR) from gloves used in cleanrooms where spacecraft are assembled, cleaned, or tested. 1.2 The NVR of interest is that which can be extracted from gloves using a specified solvent that has been selected for its extracting qualities, or because it is representative of solvents used in the particular facility. Alternative solvents may be used, but since their use may result in different values being generated, they must be identified in the procedure data sheet. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  20. The BOXES Methodology Black Box Dynamic Control

    CERN Document Server

    Russell, David W

    2012-01-01

    Robust control mechanisms customarily require knowledge of the system’s describing equations which may be of the high order differential type.  In order to produce these equations, mathematical models can often be derived and correlated with measured dynamic behavior.  There are two flaws in this approach one is the level of inexactness introduced by linearizations and the other when no model is apparent.  Several years ago a new genre of control systems came to light that are much less dependent on differential models such as fuzzy logic and genetic algorithms. Both of these soft computing solutions require quite considerable a priori system knowledge to create a control scheme and sometimes complicated training program before they can be implemented in a real world dynamic system. Michie and Chambers’ BOXES methodology created a black box system that was designed to control a mechanically unstable system with very little a priori system knowledge, linearization or approximation.  All the method need...

  1. The measurement of water vapor permeability of glove materials using dilute tritiated water

    International Nuclear Information System (INIS)

    Doughty, D.H.

    1982-01-01

    As fusion technology progresses, there will be an increasing need to handle tritium and tritiated compounds. Protective clothing, especially drybox gloves, must be an effective barrier to minimize worker exposure. The water vapor permeability of glove materials and finished glove constructions is a crucial property of drybox gloves and is not sufficiently well characterized. We have built an apparatus that measures water vapor permeability of elastomers using dilute tritiated water. The technique is more sensitive than other methods currently available and allows us to make measurements on materials and under conditions previously inaccessible. In particular, we present results on laminated drybox gloves for which data is not currently available. (orig.)

  2. Tactile Gloves for Autonomous Grasping With the NASA/DARPA Robonaut

    Science.gov (United States)

    Martin, T. B.; Ambrose, R. O.; Diftler, M. A.; Platt, R., Jr.; Butzer, M. J.

    2004-01-01

    Tactile data from rugged gloves are providing the foundation for developing autonomous grasping skills for the NASA/DARPA Robonaut, a dexterous humanoid robot. These custom gloves compliment the human like dexterity available in the Robonaut hands. Multiple versions of the gloves are discussed, showing a progression in using advanced materials and construction techniques to enhance sensitivity and overall sensor coverage. The force data provided by the gloves can be used to improve dexterous, tool and power grasping primitives. Experiments with the latest gloves focus on the use of tools, specifically a power drill used to approximate an astronaut's torque tool.

  3. Trial Production of Surgical Gloves from Irradiated Natural Rubber Latex on Factory Scale

    Directory of Open Access Journals (Sweden)

    M. Utama

    2005-07-01

    Full Text Available Trial production of surgical gloves from irradiated natural rubber latex at the PT. Laxindo Utama Serang Banten glove factory has been carried out. The variation of heating temperature and leaching time during processing were evaluated. The physical and mechanical properties and the protein allergen respond of surgical gloves using ELISA method were measured. The results showed that the physical and mechanical of surgical gloves such as tensile strength, modulus, and elongation at break arefound to meet the requirements of the ISO or SNI standard for surgical gloves. While the allergic response through clinical tested latex-sensitive protein allergen known as ELISA test is found to be negative.

  4. Hand Rehabilitation Learning System With an Exoskeleton Robotic Glove.

    Science.gov (United States)

    Ma, Zhou; Ben-Tzvi, Pinhas; Danoff, Jerome

    2016-12-01

    This paper presents a hand rehabilitation learning system, the SAFE Glove, a device that can be utilized to enhance the rehabilitation of subjects with disabilities. This system is able to learn fingertip motion and force for grasping different objects and then record and analyze the common movements of hand function including grip and release patterns. The glove is then able to reproduce these movement patterns in playback fashion to assist a weakened hand to accomplish these movements, or to modulate the assistive level based on the user's or therapist's intent for the purpose of hand rehabilitation therapy. Preliminary data have been collected from healthy hands. To demonstrate the glove's ability to manipulate the hand, the glove has been fitted on a wooden hand and the grasping of various objects was performed. To further prove that hands can be safely driven by this haptic mechanism, force sensor readings placed between each finger and the mechanism are plotted. These experimental results demonstrate the potential of the proposed system in rehabilitation therapy.

  5. Assessment of adverse reactions to latex gloves use among nurses ...

    African Journals Online (AJOL)

    A cross sectional study was carried out amongst 235 nurses at Mankweng Hospital using a self-administered questionnaire to collect information about history of allergic reaction, family history, signs and symptoms of adverse reactions after using latex gloves. Among 155 nurses who responded to the questionnaire (66% ...

  6. Determination of an Ergonomically Sound Glovebox Glove Port Center Line

    International Nuclear Information System (INIS)

    Christman, Marissa St; Land, Whitney Morgan

    2016-01-01

    Determine an ergonomic glovebox glove port center line location which will be used for standardization in new designs, thus allowing for predictable human work performance, reduced worker exposure to radiation and musculoskeletal injury risks, and improved worker comfort, efficiency, health, and safety.

  7. Usage of Safety Gloves in the Gold Mining Industry

    CSIR Research Space (South Africa)

    Scheepers, JCE

    1978-10-01

    Full Text Available The safety departments of 31 mines were visited, and the data obtained was used to determine to what extent safety gloves were being used in the gold mining industry. The frequency of occurrence of hand injuries amongst black workers of the gold...

  8. Determination of an Ergonomically Sound Glovebox Glove Port Center Line

    Energy Technology Data Exchange (ETDEWEB)

    Christman, Marissa St John [Los Alamos National Laboratory

    2016-11-30

    Determine an ergonomic glovebox glove port center line location which will be used for standardization in new designs, thus allowing for predictable human work performance, reduced worker exposure to radiation and musculoskeletal injury risks, and improved worker comfort, efficiency, health, and safety.

  9. Safety of the surgeon: 'Double-gloving' during surgical procedures

    African Journals Online (AJOL)

    The surgeon and the first assistant double-gloved in all the 1 050 procedures performed between 2009 and 2013, and ... physician's hands.[1]. Recently, the protection of physicians and other medical personnel from the percutaneous transmission of HIV, hepatitis-B virus and other pathogens by direct contact with infected ...

  10. Exploiting wearable goniometer technology for motion sensing gloves.

    Science.gov (United States)

    Carbonaro, Nicola; Dalle Mura, Gabriele; Lorussi, Federico; Paradiso, Rita; De Rossi, Danilo; Tognetti, Alessandro

    2014-11-01

    This paper presents an innovative wearable kinesthetic glove realized with knitted piezoresistive fabric (KPF) sensor technology. The glove is conceived to capture hand movement and gesture by using KPF in a double-layer configuration working as angular sensors (electrogoniometers). The sensing glove prototype is endowed by three KPF goniometers, used to track flexion and extension movement of metacarpophalangeal joint of thumb, index, and middle fingers. The glove is devoted to the continuous monitoring of patients during their daily-life activities, in particular for stroke survivors during their rehabilitation. The prototype performances have been evaluated in comparison with an optical tracking system considered as a gold standard both for relieving static and dynamic posture and gesture of the hand. The introduced prototype has shown very interesting figures of merit. The angular error, evaluated through the standard Bland Altman analysis, has been estimated in ±3° which is slightly less accurate than commercial electrogoniometers. Moreover, a new conceptual prototype design, preliminary evaluated within this study, is presented and discussed in order to solve actual limitations in terms of number and type of sensor connections, avoiding mechanical constraints given by metallic inextensible wires and improving user comfort.

  11. [Do double gloves protect against contamination during cannulation of blood vessels? A prospective randomized study].

    Science.gov (United States)

    Szarpak, Łukasz; Kurowski, Andrzej

    2014-01-01

    Undamaged medical gloves protect medical personnel from contact with physiological fluids of the patient. Thus they protect the assistance provider from hand skin contamination with potentially infectious biological materials. The aim of the study was to evaluate the occurrence of pierce, perforations or damage of medical gloves during cannulation of blood vessels. In the prospective randomized study 303 pairs of gloves, used during cannulation of blood vessels under simulated resuscitation, were analyzed. Gloves were tested by the water leak test. The water test revealed 44 cases of damage to the gloves used during cannulation of blood vessels. Significant differences were noted in the frequency of damage to both the outer and single pairs of gloves and the inner pair of gloves. The study showed that the use of double gloves provides a higher level of security for a paramedic than the use of a single pair of gloves, however, double gloves reduce the manual dexterity of a paramedic. A large number of damages to gloves are not noticed by medical personnel during surgery.

  12. Latex Rubber Gloves as a Sampling Dosimeter Using a Novel Surrogate Sampling Device.

    Science.gov (United States)

    Sankaran, Gayatri; Lopez, Terry; Ries, Steve; Ross, John; Vega, Helen; Eastmond, David A; Krieger, Robert I

    2015-01-01

    Pesticide exposure during harvesting of crops occurs primarily to the workers' hands. When harvesters wear latex rubber gloves for personal safety and hygiene harvesting reasons, gloves accumulate pesticide residues. Hence, characterization of the gloves' properties may be useful for pesticide exposure assessments. Controlled field studies were conducted using latex rubber gloves to define the factors that influence the transfer of pesticides to the glove and that would affect their use as a residue monitoring device. A novel sampling device called the Brinkman Contact Transfer Unit (BCTU) was constructed to study the glove characteristics and residue transfer and accumulation under controlled conditions on turf. The effectiveness of latex rubber gloves as sampling dosimeters was evaluated by measuring the transferable pesticide residues as a function of time. The validation of latex rubber gloves as a residue sampling dosimeter was performed by comparing pesticide transfer and dissipation from the gloves, with the turf transferable residues sampled using the validated California (CA) Roller, a standard measure of residue transfer. The observed correlation (Pearson's correlation coefficient R(2)) between the two methods was .84 for malathion and .96 for fenpropathrin, indicating that the BCTU is a useful, reliable surrogate tool for studying available residue transfer to latex rubber gloves under experimental conditions. Perhaps more importantly, these data demonstrate that latex gloves worn by workers may be useful quantifiable matrices for measuring pesticide exposure.

  13. A study of clinicians' views on medical gloves and their effect on manual performance.

    Science.gov (United States)

    Mylon, Peter; Lewis, Roger; Carré, Matt J; Martin, Nicolas; Brown, Steven

    2014-01-01

    The effect of gloves on practitioners' performance has not been a major factor in their design. To determine the critical elements of performance and design appropriate tests, data from clinicians were needed. Semistructured interviews were carried out with medical practitioners from various disciplines, in which they were asked about their glove use, their views on gloves, medical tasks requiring the highest manual performance or most affected by gloves, and what the main issues with glove use were. Many participants expressed a preference for latex over nitrile, with glove fit being the main reason given. Satisfaction with surgical gloves (generally latex) was high but less so with examination gloves, which were generally nitrile. Tactile sensation, comfort, and donning were also seen as major issues with glove use. A number of tasks were identified for possible development as tests. Performance in medical practice needs to be clearly defined, separating perceived and measured performance, and understanding the effect of glove material, fit, and thickness. Development of new glove performance tests based on the tasks identified is an important part of this. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  14. Permeability of different types of medical protective gloves to acrylic monomers.

    Science.gov (United States)

    Lönnroth, Emma-Christin; Wellendorf, Hanne; Ruyter, Eystein

    2003-10-01

    Dental personnel and orthopedic surgeons are at risk when manually handling products containing methyl methacrylate (MMA). Dental products may also contain cross-linking agents such as ethylene glycol dimethacrylate (EGDMA) or 1,4-butanediol dimethacrylate (1,4-BDMA). Skin contact with monomers can cause hand eczema, and the protection given by gloves manufactured from different types of material is not well known. The aim of this study was to determine the breakthrough time (BTT, min) as a measure of protection (according to the EU standard EN-374-3) for a mixture consisting of MMA, EGDMA and 1,4-BDMA. Fifteen different gloves representing natural rubber latex material, synthetic rubber material (e.g. nitrile rubbers), and synthetic polymer material were tested. The smallest monomer MMA permeated within 3 min through all glove materials. A polyethylene examination glove provided the longest protection period to EGDMA and 1, 4-BDMA (> 120 min and 25.0 min), followed by the surgical glove Tactylon (6.0 min and 8.7 min) and the nitrile glove Nitra Touch (5.0 min and 8.7 min). This study showed that the breakthrough time (based on permeation rate) cannot be regarded as a 'safe limit'. When the permeation rate is low, monomers may have permeated before BTT can be determined. Using double gloves with a synthetic rubber inner glove and a natural rubber outer glove provided longer protection when the inner glove was rinsed in water before placing the outer glove on top.

  15. Opto-Box

    CERN Document Server

    Bertsche, David; The ATLAS collaboration; Welch, Steven; Smith, Dale Shane; Che, Siinn; Gan, K.K.; Boyd, George Russell Jr

    2015-01-01

    The opto-box is a custom mini-crate for housing optical modules, which process and transfer optoelectronic data. The system tightly integrates electrical, mechanical, and thermal functionality into a small package of size 35x10x8 cm^3. Special attention was given to ensure proper shielding, grounding, cooling, high reliability, and environmental tolerance. The custom modules, which incorporate Application Specific Integrated Circuits (ASICs), were developed through a cycle of rigorous testing and redesign. In total, fourteen opto-boxes have been installed and loaded with modules on the ATLAS detector. They are currently in operation as part of the LHC run 2 data read-out chain.

  16. Investigation of the effects of extravehicular activity (EVA) gloves on performance

    Science.gov (United States)

    Bishu, Ram R.; Klute, Glenn

    1993-01-01

    The objective was to assess the effects of extravehicular activity (EVA) gloves at different pressures on human hand capabilities. A factorial experiment was performed in which three types of EVA gloves were tested at five pressure differentials. The independent variables tested in this experiment were gender, glove type, pressure differential, and glove make. Six subjects participated in an experiment where a number of dexterity measures, namely time to tie a rope, and the time to assemble a nut and bolt were recorded. Tactility was measured through a two point discrimination test. The results indicate that with EVA gloves strength is reduced by nearly 50 percent, there is a considerable reduction in dexterity, performance decrements increase with increasing pressure differential, and some interesting gender glove interactions were observed, some of which may have been due to the extent (or lack of) fit of the glove to the hand. The implications for the designer are discussed.

  17. Safety analysis report for the 238PuO2 fuel form facility

    International Nuclear Information System (INIS)

    Angerman, C.L.; Bickford, D.F.; Gould, T.H. Jr.; Smith, P.K.

    1977-08-01

    The Plutonium Fuel Form (PuFF) Facility has been constructed at the Savannah River Plant to manufacture 30 to 60 kg/yr of 238 Pu fuel forms for space power applications. This facility is located in the existing Building 235-F near the geographical center of the Savannah River Plant (SRP) site. Pilot production is scheduled to begin in July 1977, with full-scale production in April 1978. The process line of the facility consists of nine separate, interconnected shielded cells; five shielded wing cabinets or glove boxes; three hoods; and contained auxiliary equipment. These process enclosures will be, for the most part, under an atmosphere of recirculating inert gas. The products of the facility will be dense fuel forms manufactured from PuO 2 powder with a nominal isotopic composition of 80% 238 Pu-20% 239 Pu. This powder, made from calcined oxalate, has been produced safely at a rate of about 20 kg 238 Pu/yr in the H-Area B-Line in Building 221-H for approximately ten years. This report describes design objectives, nature of operations, potential hazards and limiting factors, facility response to postulated accidents and failures, and environmental effects. The results of the analyses described in this report indicate that the facility has the capacity to prevent or sufficiently reduce accidents that represent potential risks to health and safety. The safety analysis in conjunction with process requirements provides the bases for Technical Standards for operation. The analysis also documents the degree of conformance of the facility design with the General Design Criteria - Plutonium Facilities and the Environmental Statement

  18. Is clinical performance adversely affected by wearing gloves during paediatric peripheral intravenous cannulation?

    Science.gov (United States)

    Zhang, Michael; Lee, Mark; Knott, Susan

    2014-10-01

    To investigate if wearing protective gloves during paediatric intravenous cannulation affects performance of the procedure. This was a prospective observational study. Peripheral intravenous cannulation (PIVC) performed within the Paediatric ED was observed and recorded over a 12 month period. Data were compared between those clinicians wearing gloves and those not wearing gloves during PIVC. One thousand and twenty paediatric cannulations were recorded during the observed period. The mean age of the children was 5.79 years. The overall success rate of cannulation was 86.18% and first attempt success rate 76.08%. Overall, gloves were used by 54.31% of clinicians to establish vascular access; glove use was lowest in the registrar group (41.11% compliance rate). The glove-wearing group had comparable overall success rate of 85.74% (475/554) to the no-gloves group of 86.70% (404/466). The difference was not statistically significant (P > 0.05). Higher incidence of significant blood spillage during the procedure was observed among clinicians wearing no gloves (16.74%) in comparison with their glove-wearing counterparts (9.03%, P glove-wearing group and no-gloves group (3.94% vs 3.76%, P > 0.05). The present study shows that the use of protective gloves was not associated with adverse outcomes of clinical performance during paediatric cannulation. The low compliance rate of gloves use is alarming, and many clinicians might be exposed to potential blood-borne infections. Clinicians should be encouraged and supported to use gloves for paediatric cannulation. © 2014 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  19. An evaluation of the permeability of chemotherapy gloves to three cancer chemotherapy drugs.

    Science.gov (United States)

    Singleton, L C; Connor, T H

    1999-10-01

    To evaluate the permeability of chemotherapy gloves when using carmustine (BCNU), etoposide, and paclitaxel, which were selected based on their reported toxicity and unique solvent systems. Thirteen brands of chemotherapy gloves and one brand of examination glove. Of the 14 glove types tested, 11 were made of latex, and 3 were made of nitrile. Ten samples of each type of glove were evaluated using rigorous laboratory test conditions usually not encountered in normal usage. The thickness of the gloves was measured using a digital caliper. The glove material was secured over glass vials containing the drug solution and inverted in plastic cell wells containing a filter paper disc. After a two-hour exposure time, the filter paper discs were removed and analyzed for the presence of the drug. Permeability (i.e., greater than or equal to 1% of the total amount of drug passing through the glove material.) All 14 types of gloves tested were impermeable to BCNU at two hours of exposure. Only two gloves, the Ansell Perry EP glove and the U.S. Clinical Chemo Bloc T glove, were impermeable to all three drugs. The remaining 12 gloves all demonstrated some level of permeation with etoposide at two hours, although 9 of the gloves had only 1 of 10 samples that were permeable. In all cases, percent of permeation was less than 2% of the amount of the drug in the test solution. Thirteen gloves tested for paclitaxel permeability were impermeable at the two-hour time period. The results of this study indicate that most of the chemotherapy gloves on the market are either impermeable or minimally permeable to these three chemotherapy drugs. Because gloves are universally recognized as a means of personal protection when handling cancer chemotherapy drugs, selection of a glove that is impermeable would be an obvious choice for healthcare workers. Although the present study was a static, laboratory-based study that did not duplicate actual work practice conditions. It should offer some

  20. Teaching with Box Tops.

    Science.gov (United States)

    Raiser, Lynne; D'Zamko, Mary Elizabeth

    1984-01-01

    Using environmental materials (such as the phone book and placemats from fast food restaurants) can be a motivating way to teach learning disabled students skills and concepts, as shown in an approach to reading, math, science and nutrition, and social studies instruction using a JELL-O brand gelatin box. (CL)

  1. Many-box locality

    Science.gov (United States)

    Zhou, Yuqian; Cai, Yu; Bancal, Jean-Daniel; Gao, Fei; Scarani, Valerio

    2017-11-01

    There is an ongoing search for a physical or operational definition for quantum mechanics. Several informational principles have been proposed which are satisfied by a theory less restrictive than quantum mechanics. Here, we introduce the principle of "many-box locality," which is a refined version of the previously proposed "macroscopic locality." These principles are based on coarse graining the statistics of several copies of a given box. The set of behaviors satisfying many-box locality for N boxes is denoted LNM B. We study these sets in the bipartite scenario with two binary measurements, in relation with the sets Q and Q1 +A B of quantum and "almost quantum" correlations, respectively. We find that the LNM B sets are, in general, not convex. For unbiased marginals, by working in the Fourier space we can prove analytically that LNM B⊈Q for any finite N , while L∞M B=Q . Then, with suitably developed numerical tools, we find an example of a point that belongs to L16M B but not to Q1 +A B. Among the problems that remain open is whether Q ⊂L∞M B .

  2. Mystery Box Marvels

    Science.gov (United States)

    Santos, Joel; Centurio, Tina

    2012-01-01

    What happens in the first week of school could very well set the stage for the rest of the school year. Setting high standards for science activities based in inquiry can start on the first day of science class and develop as the year unfolds. With the use of simple, readily available, inexpensive materials, an efficient mystery box lesson can be…

  3. IN-A-BOX

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 7; Issue 2. Claude Elwood Shannon. Priti Shankar. Article-in-a-Box Volume 7 Issue 2 February 2002 pp 2-3 ... Author Affiliations. Priti Shankar1. Department of Computer Science & Automation, Indian Institute of Science, Bangalore 560 012, India.

  4. IN-A-BOX

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 6; Issue 12. Vikram A Sarabhai. Mrinalini Sarabhai. Article-in-a-Box Volume 6 Issue 12 December 2001 pp 5-7. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/006/12/0005-0007. Author Affiliations. Mrinalini ...

  5. Anatomy of a defective barrier: sequential glove leak detection in a surgical and dental environment.

    Science.gov (United States)

    Albin, M S; Bunegin, L; Duke, E S; Ritter, R R; Page, C P

    1992-02-01

    a) To determine the frequency of perforations in latex surgical gloves before, during, and after surgical and dental procedures; b) to evaluate the topographical distribution of perforations in latex surgical gloves after surgical and dental procedures; and c) to validate methods of testing for latex surgical glove patency. Multitrial tests under in vitro conditions and a prospective sequential patient study using consecutive testing. An outpatient dental clinic at a university dental school, the operating suite in a medical school affiliated with the Veteran's Hospital, and a biomechanics laboratory. Surgeons, scrub nurses, and dental technicians participating in 50 surgical and 50 dental procedures. We collected 679 latex surgical gloves after surgical procedures and tested them for patency by using a water pressure test. We also employed an electronic glove leak detector before donning, after sequential time intervals, and upon termination of 47 surgical (sequential surgical), 50 dental (sequential dental), and in three orthopedic cases where double gloving was used. The electronic glove leak detector was validated by using electronic point-by-point surface probing, fluorescein dye diffusion, as well as detecting glove punctures made with a 27-gauge needle. The random study indicated a leak rate of 33.0% (224 out of 679) in latex surgical gloves; the sequential surgical study demonstrated patency in 203 out of 347 gloves (58.5%); the sequential dental study showed 34 leaks in the 106 gloves used (32.1%); and with double gloving, the leak rate decreased to 25.0% (13 of 52 gloves tested). While the allowable FDA defect rate for unused latex surgical gloves is 1.5%, we noted defect rates in unused gloves of 5.5% in the sequential surgical, 1.9% in the sequential dental, and 4.0% in our electronic glove leak detector validating study. In the sequential surgical study, 52% of the leaks had occurred by 75 mins, and in the sequential dental study, 75% of the leaks

  6. Safety evaluation for packaging (onsite) depleted uranium waste boxes

    Energy Technology Data Exchange (ETDEWEB)

    McCormick, W.A.

    1997-08-27

    This safety evaluation for packaging (SEP) allows the one-time shipment of ten metal boxes and one wooden box containing depleted uranium material from the Fast Flux Test Facility to the burial grounds in the 200 West Area for disposal. This SEP provides the analyses and operational controls necessary to demonstrate that the shipment will be safe for the onsite worker and the public.

  7. Safety evaluation for packaging (onsite) depleted uranium waste boxes

    International Nuclear Information System (INIS)

    McCormick, W.A.

    1997-01-01

    This safety evaluation for packaging (SEP) allows the one-time shipment of ten metal boxes and one wooden box containing depleted uranium material from the Fast Flux Test Facility to the burial grounds in the 200 West Area for disposal. This SEP provides the analyses and operational controls necessary to demonstrate that the shipment will be safe for the onsite worker and the public

  8. Methodology for evaluating gloves in relation to the effects on hand performance capabilities: a literature review.

    Science.gov (United States)

    Dianat, Iman; Haslegrave, Christine M; Stedmon, Alex W

    2012-01-01

    The present study was conducted to review the literature on the methods that have been considered appropriate for evaluation of the effects of gloves on different aspects of hand performance, to make recommendations for the testing and assessment of gloves, and to identify where further research is needed to improve the evaluation protocols. Eighty-five papers meeting the criteria for inclusion were reviewed. Many studies show that gloves may have negative effects on manual dexterity, tactile sensitivity, handgrip strength, muscle activity and fatigue and comfort, while further research is needed to determine glove effects on pinch strength, forearm torque strength and range of finger and wrist movements. The review also highlights several methodological issues (including consideration of both task type and duration of glove use by workers, guidance on the selection and allocation of suitable glove(s) for particular tasks/jobs, and glove design features) that need to be considered in future research. Practitioner Summary: The relevant literature on the effects of protective gloves on different aspects of hand performance was reviewed to make recommendations for the testing and assessment of gloves, and to improve evaluation protocols. The review highlights research areas and methodological issues that need to be considered in future research.

  9. Vibration-reducing gloves: transmissibility at the palm of the hand in three orthogonal directions.

    Science.gov (United States)

    McDowell, Thomas W; Dong, Ren G; Welcome, Daniel E; Xu, Xueyan S; Warren, Christopher

    2013-01-01

    Vibration-reducing (VR) gloves are commonly used as a means to help control exposures to hand-transmitted vibrations generated by powered hand tools. The objective of this study was to characterise the vibration transmissibility spectra and frequency-weighted vibration transmissibility of VR gloves at the palm of the hand in three orthogonal directions. Seven adult males participated in the evaluation of seven glove models using a three-dimensional hand-arm vibration test system. Three levels of hand coupling force were applied in the experiment. This study found that, in general, VR gloves are most effective at reducing vibrations transmitted to the palm along the forearm direction. Gloves that are found to be superior at reducing vibrations in the forearm direction may not be more effective in the other directions when compared with other VR gloves. This casts doubts on the validity of the standardised glove screening test. Practitioner Summary: This study used human subjects to measure three-dimensional vibration transmissibility of vibration-reducing gloves at the palm and identified their vibration attenuation characteristics. This study found the gloves to be most effective at reducing vibrations along the forearm direction. These gloves did not effectively attenuate vibration along the handle axial direction.

  10. Vibration-reducing gloves: transmissibility at the palm of the hand in three orthogonal directions

    Science.gov (United States)

    McDowell, Thomas W.; Dong, Ren G.; Welcome, Daniel E.; Xu, Xueyan S.; Warren, Christopher

    2015-01-01

    Vibration-reducing (VR) gloves are commonly used as a means to help control exposures to hand-transmitted vibrations generated by powered hand tools. The objective of this study was to characterise the vibration transmissibility spectra and frequency-weighted vibration transmissibility of VR gloves at the palm of the hand in three orthogonal directions. Seven adult males participated in the evaluation of seven glove models using a three-dimensional hand–arm vibration test system. Three levels of hand coupling force were applied in the experiment. This study found that, in general, VR gloves are most effective at reducing vibrations transmitted to the palm along the forearm direction. Gloves that are found to be superior at reducing vibrations in the forearm direction may not be more effective in the other directions when compared with other VR gloves. This casts doubts on the validity of the standardised glove screening test. Practitioner Summary This study used human subjects to measure three-dimensional vibration transmissibility of vibration-reducing gloves at the palm and identified their vibration attenuation characteristics. This study found the gloves to be most effective at reducing vibrations along the forearm direction. These gloves did not effectively attenuate vibration along the handle axial direction. PMID:24160755

  11. Transport of a solvent mixture across two glove materials when applied in a paint matrix.

    Science.gov (United States)

    Tran, Jackelin Q; Ceballos, Diana M; Dills, Russell L; Yost, Michael G; Morgan, Michael S

    2012-07-01

    The transport of mixed paint solvents through natural rubber latex (4 mil) and nitrile rubber (5 mil) gloves was evaluated after spray application of the paint formulation directly on the glove surface. Glove materials and thicknesses were those selected by the majority of spray painters in the local automobile repair industry. A flat panel containing glove specimens mounted in multiple permeation cells permitted evaporation of solvents from the applied paint and incorporated a solid sorbent receiving medium for measuring glove membrane transport. The panel was sprayed in a paint booth to simulate use conditions. Charcoal cloth under the glove adsorbed transported solvents, which were quantified by gas chromatography. For each solvent component, results were expressed as mass transported through the glove relative to the mass applied, per unit area, during 30 min after spray application. The paint formulation contained ketones, acetates, and aromatics. Natural rubber latex allowed 6-10 times the transport of solvents relative to nitrile rubber for all eight solvent components: methyl ethyl ketone, toluene, styrene, ethyl benzene, xylene isomers, and 2-heptanone. m-Xylene showed the largest difference in transport between the two glove materials. This solvent also had the highest transport for each material. The results indicate that nitrile rubber gloves offer somewhat greater chemical resistance to all eight solvents studied compared with natural rubber latex gloves, regardless of the chemical properties of the individual solvent components. However, it must be emphasized that neither of the glove materials, in the thicknesses used in this study, provide adequate protection when exposed by direct spray painting. Simulation of realistic spray conditions may offer a source of useful information on the performance of chemical protective gloves because it accounts for solvent evaporation and the effect of paint polymerization after application on glove transport.

  12. Development of a prototype movement assistance system for extravehicular activity gloves

    Science.gov (United States)

    Hill, Tyler N.

    Spacesuits utilized a rubberized layer of material to contain a pressurized atmosphere to facilitate respiration and maintain the physiologic functions of the astronaut residing within. However, the elasticity of the material makes it resistant to deformation increasing the amount of work required during movement. This becomes particularly fatiguing for the muscle groups controlling the motion of the hands and fingers. To mitigate this a robotic system was proposed and developed. The system built upon previous concepts and prototypes discovered through research efforts. It utilized electric motors to pull the index, ring, and middle fingers of the right hand closed, ideally overcoming the resistive force posed by the pressurized elastic material. The effect of the system was determined by comparing qualitative and quantitative data obtained during activities conducted with and without it within a glove box. It was found that the system was able to offload some of this elastic force though several characteristics of the design limited the full potential this device offered. None the less, the project was met with success and provides a solid platform for continued research and development.

  13. Opto-Box

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00377159; The ATLAS collaboration

    2015-01-01

    The opto-box is a custom mini-crate for housing optical modules, which process and transfer optoelectronic data. Many novel solutions were developed for the custom design and manufacturing. The system tightly integrates electrical, mechanical, and thermal functionality into a small package of size 35x10x8 cm$^{3}$. Special attention was given to ensure proper shielding, grounding, cooling, high reliability, and environmental tolerance. The custom modules, which incorporate Application Specific Integrated Circuits (ASICs), were developed through a cycle of rigorous testing and redesign. In total, fourteen opto-boxes have been installed and loaded with modules on the ATLAS detector. They are currently in operation as part of the LHC run 2 data read-out chain.

  14. An Instrumented Glove for Control Audiovisual Elements in Performing Arts

    Directory of Open Access Journals (Sweden)

    Rafael Tavares

    2018-02-01

    Full Text Available The use of cutting-edge technologies such as wearable devices to control reactive audiovisual systems are rarely applied in more conventional stage performances, such as opera performances. This work reports a cross-disciplinary approach for the research and development of the WMTSensorGlove, a data-glove used in an opera performance to control audiovisual elements on stage through gestural movements. A system architecture of the interaction between the wireless wearable device and the different audiovisual systems is presented, taking advantage of the Open Sound Control (OSC protocol. The developed wearable system was used as audiovisual controller in “As sete mulheres de Jeremias Epicentro”, a portuguese opera by Quarteto Contratempus, which was premiered in September 2017.

  15. FDM 3D printed coffee glove embedded with flexible electronic

    KAUST Repository

    Bahri, Meznan

    2017-10-31

    With the advances in 3D printing technology, Flexible Electronics can now be exploited to form the so-called “Embedded Electronics”. This paper describes experiences learned from a research project which ran during summer 2016 at KAUST, in collaboration with the Electrical and Computer Engineering Department at Effat University, and aimed at creating a heating coffee glove product operating on double alkaline batteries using Kapton© as a flexible substrate for the circuit. The circuit and its batteries are encapsulated in a 3D printed glove, designed using SolidWorks©. The proposed methodology and techniques applied during this work could be further used in implementing other technologies, such as thermoelectric coolers head patches, smart garments, and flexible smartphones. Limitation and recommendation of the present methodology are also discussed.

  16. Boxed Permutation Pattern Matching

    DEFF Research Database (Denmark)

    Amit, Mika; Bille, Philip; Cording, Patrick Hagge

    2016-01-01

    the goal is to only find the boxed subsequences of T that are order-isomorphic to P. This problem was introduced by Bruner and Lackner who showed that it can be solved in O(n3) time. Cho et al. [CPM 2015] gave an O(n2m) time algorithm and improved it to O(n2 logm). In this paper we present a solution...

  17. The Box Method

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm

    The velocity level in a room ventilated by jet ventilation is strongly influenced by the supply conditions. The momentum flow in the supply jets controls the air movement in the room and, therefore, it is very important that the inlet conditions and the numerical method can generate a satisfactor...... description of this momentum flow. The Box Method is a practical method for the description of an Air Terminal Device which will save grid points and ensure the right level of the momentum flow....

  18. Compression under a mechanical counter pressure space suit glove

    Science.gov (United States)

    Waldie, James M A.; Tanaka, Kunihiko; Tourbier, Dietmar; Webb, Paul; Jarvis, Christine W.; Hargens, Alan R.

    2002-01-01

    Background: Current gas-pressurized space suits are bulky stiff shells severely limiting astronaut function and capability. A mechanical counter pressure (MCP) space suit in the form of a tight elastic garment could dramatically improve extravehicular activity (EVA) dexterity, but also be advantageous in safety, cost, mass and volume. The purpose of this study was to verify that a prototype MCP glove exerts the design compression of 200 mmHg, a pressure similar to the current NASA EVA suit. Methods: Seven male subjects donned a pressure measurement array and MCP glove on the right hand, which was placed into a partial vacuum chamber. Average compression was recorded on the palm, the bottom of the middle finger, the top of the middle finger and the dorsum of the hand at pressures of 760 (ambient), 660 and 580 mmHg. The vacuum chamber was used to simulate the pressure difference between the low breathing pressure of the current NASA space suits (approximately 200 mmHg) and an unprotected hand in space. Results: At ambient conditions, the MCP glove compressed the dorsum of the hand at 203.5 +/- 22.7 mmHg, the bottom of the middle finger at 179.4 +/- 16.0 mmHg, and the top of the middle finger at 183.8 +/- 22.6 mmHg. The palm compression was significantly lower (59.6 +/- 18.8 mmHg, pglove compression with the chamber pressure reductions. Conclusions: The MCP glove compressed the dorsum of the hand and middle finger at the design pressure.

  19. Cotton liners to mediate glove comfort for greenhouse applicators.

    Science.gov (United States)

    Stone, J; Coffman, C; Imerman, P M; Song, K; Shelley, M

    2005-10-01

    Greenhouse applicators' acceptance of cotton knit gloves worn as liners under nitrile chemical-resistant gloves (CRG) for pesticide application was investigated through a wear study in Iowa and New York. Comfort was assessed by questionnaires and interviews with 10 applicators. Contamination levels of four pesticides on CRG and liners at thumb, forefinger, palm, and cuff locations were determined by chemical analysis using high-performance liquid chromatography or gas chromatography. Applicators reported feeling more comfortable with cotton liners under their CRG than without and that cotton liners were easy to manage. Contamination was significantly greater on nitrile CRG than on cotton liners underneath, but a few liner specimens had measurable contamination. No significant contamination differences were found between right- and left-hand gloves. Contamination varied significantly by hand location, with cuffs least, and by pesticide, with chlorpyrifos most. These results support the Environmental Protection Agency's recommendation that liners should be disposable, but further work on liners and their laundering feasibility seems indicated.

  20. Finger doses during interventional radiology: The value of flexible protective gloves

    International Nuclear Information System (INIS)

    Vehmas, T.

    1991-01-01

    Finger doses of radiologists and assistants during 19 interventional radiological procedures were measured with thermoluminescent dosimeters (TLDs), and two types of flexible protective gloves were compared with each other. There were considerable differences in doses between different sites of TLDs on fingers. The exact site of TLDs on hands/fingers should thus be reported in papers. Both gloves were also irradiated through an Alderson phantom and the attenuation values were measured. The gloves with slightly greater attenuation proved to be significantly less comfortable to use. Wearing flexible protective gloves did not lengthen screening times as compared to a previous study in the same department. Various aspects of using such gloves are discussed. The attenuation values of gloves reported by the manufacturers may not apply under all clinical circumstances. (orig.) [de

  1. Effect of shelf aging on vibration transmissibility of anti-vibration gloves

    Science.gov (United States)

    SHIBATA, Nobuyuki

    2017-01-01

    Anti-vibration gloves have been used in real workplaces to reduce vibration transmitted through hand-held power tools to the hand. Generally materials used for vibration attenuation in gloves are resilient materials composed of certain synthetic and/or composite polymers. The mechanical characteristics of the resilient materials used in anti-vibration gloves are prone to be influenced by environmental conditions such as temperature, humidity, and photo-irradiation, which cause material degradation and aging. This study focused on the influence of shelf aging on the vibration attenuation performance of air-packaged anti-vibration gloves following 2 yr of shelf aging. Effects of shelf aging on the vibration attenuation performance of anti-vibration gloves were examined according to the Japan industrial standard JIS T8114 test protocol. The findings indicate that shelf aging induces the reduction of vibration attenuation performance in air-packaged anti-vibration gloves. PMID:28978817

  2. Investigation of X-ray permeability of surgical gloves coated with different contrast agents

    Science.gov (United States)

    Kayan, Mustafa; Yaşar, Selçuk; Saygın, Mustafa; Yılmaz, Ömer; Aktaş, Aykut Recep; Kayan, Fatmanur; Türker, Yasin; Çetinkaya, Gürsel

    2016-01-01

    Objective: We aimed to investigate the effectiveness and radiation protection capability of latex gloves coated with various contrast agents as an alternative to lead gloves. Methods: The following six groups were created to evaluate the permeability of X-ray in this experimental study: lead gloves, two different non-ionic contrast media (iopromide 370/100 mg I/mL and iomeprol 400/100 mg I/mL), 10% povidone–iodine (PV–I), 240/240 g/mL barium sulphate and a mixture of equal amounts of all contrast agents. A radiation dose detector was placed in coated latex gloves for each one. The absorption values of radiation from latex gloves coated with various contrast agents were measured and compared with the absorption of radiation from lead gloves. This study was designed as an ‘experimental study’. Results: The mean absorption value of X-ray from lead gloves was 3.0±0.08 µG/s. The mean absorption values of X-ray from latex gloves coated with various contrast agents were 3.7±0.09 µG/s (iopromide 370/100 mg I/mL), 3.6±0.09 µG/s (iomeprol 400/100 mg I/mL), 3.7±0.04 µG/s (PV–I), 3.1±0.07 µG/s (barium sulphate) and 3.8±0.05 µG/s (mixture of all contrast agents). Latex gloves coated with barium sulphate provided the best radiation absorption compared with latex gloves coated with other radiodense contrast agents. Conclusion: Latex gloves coated with barium sulphate may provide protection equivalent to lead gloves. PMID:26680548

  3. Evaluation of hand-arm vibration reducing effect of anti-vibration glove

    OpenAIRE

    樹野, 淳也; 前田, 節雄; 横田, 和樹; 平, 雄一郎

    2015-01-01

    Many kinds of the anti-vibration glove have been developed for reducing hand-arm vibration during the operation with vibration tools. International standard ISO 10819 evaluates the physical effect of gloves' vibration transmissibility but not evaluates the physiological effect of human hands. Thus, in this paper, we proposed the evaluation using the temporary threshold shift of vibrotactile perception threshold to evaluate the hand-arm vibration reducing effect of anti-vibration glove. We per...

  4. Permeation of hair dye ingredients, p-phenylenediamine and aminophenol isomers, through protective gloves.

    Science.gov (United States)

    Lee, Hsiao-Shu; Lin, Yu-Wen

    2009-04-01

    Skin irritation and contact allergies are skin disorders common to hairdressers. The predominant oxidative hair dye components, such as p-phenylenediamine (PPD) and aminophenol isomers, can cause contact dermatitis. Use of protective gloves can prevent dermal contact with skin irritants. This study investigates the permeation behaviors of p-aminophenol (PAP), m-aminophenol (MAP), o-aminophenol (OAP) and PPD in single and mixed challenge solutions with disposable natural rubber latex (NRL) gloves, disposable polyvinylchloride (PVC) gloves and neoprene (NP) gloves. The challenge solutions were 4% PPD (w/v), 3% OAP (w/v), 2% PAP (w/v) and 2% MAP (w/v) in ethanol or 12% hydrogen peroxide solutions. The cocktail solutions of the four chemicals were also tested. An American Society for Testing and Materials type permeation cell, ethanol liquid collection and gas chromatography-flame ionization detection of samples taken from the collection medium every 10 min facilitated determination of breakthrough times (BTs), cumulative permeated masses and steady-state permeation rates (SSPRs). Experiments were 4 h long for the NRL and PVC gloves and 8 h for NP gloves. No chemicals tested broke through the NP gloves when exposed for 8 h. In the ethanol solution, PPD and OAP started breaking through the PVC gloves at 40 min. The SSPRs of PVC gloves were higher than those for NRL gloves in all challenge conditions for both single chemicals and mixtures. No tested chemicals in hydrogen peroxide solutions permeated the gloves during the 4-h tests. The chemical composition of the challenge solution was a main effecter of BTs and SSPRs for the NRL glove. For disposable PVC gloves, the main factors of BTs were molecular size [molar volume (MV)] and polarity (logK(ow)), and the primary factors of SSPRs were concentration, MV and logK(ow). In conclusion, disposable NRL gloves and disposable PVC gloves should not be used repeatedly for handling the hair dye products. Hydrogen peroxide did not

  5. Comfort and performance of power line maintainers' gloves during electrical utility work in the cold.

    Science.gov (United States)

    Hunt, S; Boyle, C; Wells, R

    2014-01-01

    Electrical utility workers wear thick rubber gloves and often work in the cold. To document the challenge of working in the cold and the effectiveness of different glove/liner combinations in keeping workers' hands warm. Ten experienced male electrical utility employees worked in a controlled temperature walk-in chamber at -20 °C for 45 minutes for each of five glove conditions: standard five-finger rubber gloves with cotton liners and gauntlets, mitten style gloves, a prototype wool liner, and two heating options; glove or torso. Dependent measures were maximum grip force, skin temperatures, finger dexterity and sensitivity to touch, ratings of perceived effort and a rating of thermal sensation. Participants' hand skin temperatures decreased, they perceived their hands to be much colder, their finger sensitivity decreased and their ratings of perceived exertion increased, however their performance did not degrade over the 45 minute trials. The mitten-style gloves showed a smaller drop in skin temperature for the 3rd and 5th digits (pglove conditions. Mitten style gloves kept workers' hands warmer than the standard five finger glove.

  6. Thickness, permeability and tactile perception of commercial latex examination gloves used in dental practice

    Directory of Open Access Journals (Sweden)

    Shilpa Ashish Warhekar

    2015-01-01

    Full Text Available Introduction: Dentists are at an increased risk of being infected. Some patients may be unaware of their infected status while some patients are unwilling to tell the dentists their disease status. Gloves should be worn in almost all patient procedures. Aim: To assess association between thickness, tactile perception, and permeability of commercial latex examination gloves used in dental practice. Materials and Methods: The experimental study was conducted in Central India. A total of 600 gloves, 120 each from five brands (Kaltex, Nulife, Smartcare, Handshield, Medi-image were used. Thickness was measured using stereomicroscope. Permeability to fluids was evaluated through 0.2% erythrosine dye. Staphylococcus aureus (ATCC-25923 was used to check for microbial permeability. Tactile sensibility was assessed by 2-point discriminator test using 2-point-calipers on 30 volunteers. Chi-square test and Binary logistic regression analysis were used. Results: Mean thickness of gloves was 0.1333 (range: 0.1028-0.1799. Dye and microbial test showed 10.6% and 43.3% permeability of gloves, respectively. No significant difference was observed among brands. Thicker gloves (0.1285-0.1542 yielded lower touch sensibility (odds ratio: 0.783, P < 0.05. Decrease in tactility was recorded in 78.6% of volunteers with gloves compared to no gloves. Conclusion: Considerable microbial permeability suggests commercial examination gloves are unsafe. Balance between thickness, permeability and touch sensation should be established to decrease permeability maintaining same touch sensibility.

  7. Outside the box

    International Nuclear Information System (INIS)

    Pichon, Max

    2011-01-01

    Full text: Queensland-based Hydrasyst wants to take its motto of 'Do more with less' into the greywater sector with a new water recycling and energy recovery technology launched in November, called The Grey Box. The company is initially targeting large industrial laundries as they are major generators of greywater and heavy energy users, but it has ambitions well beyond that. The average commercial laundry consumes 1-5ML of water a week, using about 16 litres for every 1kg of clothing washed. Hydrasyst director Stephen Balemi said The Grey Box can slash the volume by 80 per cent. While he was reluctant to disclose too much technical detail, he claimed it is the only technology serving the $1 billion a year laundry sector that combines microfiltration / ultrafiltration membrane technology and energy reduction components. The heart of the system is a ceramic hollow fibre membrane. Balemi said it produces higher filtrate quality than competitors, meaning the recycled water can be reused more often, and can process feed water of up to 70°C compared to typical ultrafiltration membranes that cap out at about 38°C. This means the recycled water can be reused at higher temperatures, with the heat in it recovered by a precise steam heater built into The Grey Box. “As an overall measure, it saves 80 per cent of the water that is processed and saves 20 per cent of the energy,” Balemi said. Four systems have already been installed, with one going into a large commercial laundry in south Queensland and another to AMP's state-of-the-art 6 Green Star building in Brisbane. “We can modify them slightly to suit the industry, depending on the quality of raw water they are trying to recycle and also depending on the size of the project,,” said Balemi. Where many organisations build systems to specification, The Grey Box is offered in three standard sizes: the HY20 (20kL per day, based on a 10 hour day), HY80 (80kL per day) and HY130 (130kL per day). They can

  8. Tensile Properties and Integrity of Clean Room and Low-Modulus Disposable Nitrile Gloves: A Comparison of Two Dissimilar Glove Types

    Science.gov (United States)

    Phalen, Robert N.; Wong, Weng kee

    2012-01-01

    Background: The selection of disposable nitrile exam gloves is complicated by (i) the availability of several types or formulations, (ii) product variability, and (iii) an inability of common quality control tests to detect small holes in the fingers. Differences in polymer formulation (e.g. filler and plasticizer/oil content) and tensile properties are expected to account for much of the observed variability in performance. Objectives: This study evaluated the tensile properties and integrity (leak failure rates) of two glove choices assumed to contain different amounts of plasticizers/oils. The primary aims were to determine if the tensile properties and integrity differed and if associations existed among these factors. Additional physical and chemical properties were evaluated. Methods: Six clean room and five low-modulus products were evaluated using the American Society for Testing and Materials Method D412 and a modified water-leak test to detect holes capable of passing a virus or chemical agent. Results: Significant differences in the leak failure rates and tensile properties existed between the two glove types (P ≤ 0.05). The clean room gloves were about three times more likely to have leak failures (chi-square; P = 0.001). No correlation was observed between leak failures and tensile properties. Solvent extract, an indication of added plasticizer/oil, was not associated with leak failures. However, gloves with a maximum modulus gloves were a better choice for protection against aqueous chemical or biological penetration. The observed variability between glove products indicated that glove selection cannot rely solely on glove type or manufacturer labeling. Measures of modulus and AD may aid in the selection process, in contrast with common measures of tensile strength and elongation at break. PMID:22201179

  9. Tensile properties and integrity of clean room and low-modulus disposable nitrile gloves: a comparison of two dissimilar glove types.

    Science.gov (United States)

    Phalen, Robert N; Wong, Weng Kee

    2012-05-01

    The selection of disposable nitrile exam gloves is complicated by (i) the availability of several types or formulations, (ii) product variability, and (iii) an inability of common quality control tests to detect small holes in the fingers. Differences in polymer formulation (e.g. filler and plasticizer/oil content) and tensile properties are expected to account for much of the observed variability in performance. This study evaluated the tensile properties and integrity (leak failure rates) of two glove choices assumed to contain different amounts of plasticizers/oils. The primary aims were to determine if the tensile properties and integrity differed and if associations existed among these factors. Additional physical and chemical properties were evaluated. Six clean room and five low-modulus products were evaluated using the American Society for Testing and Materials Method D412 and a modified water-leak test to detect holes capable of passing a virus or chemical agent. Significant differences in the leak failure rates and tensile properties existed between the two glove types (P ≤ 0.05). The clean room gloves were about three times more likely to have leak failures (chi-square; P = 0.001). No correlation was observed between leak failures and tensile properties. Solvent extract, an indication of added plasticizer/oil, was not associated with leak failures. However, gloves with a maximum modulus <4 MPa or area density (AD) <11 g cm(-2) were about four times less likely to leak. On average, the low-modulus gloves were a better choice for protection against aqueous chemical or biological penetration. The observed variability between glove products indicated that glove selection cannot rely solely on glove type or manufacturer labeling. Measures of modulus and AD may aid in the selection process, in contrast with common measures of tensile strength and elongation at break.

  10. Focus on the studies in support of fire safety analysis. IRSN modelling approach for nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    Espargilliere, Julien; Meyrand, Raphael; Vinot, Thierry [Institut de Radioprotection et de Surete Nucleaire (IRSN), Fontenay-aux-Roses (France)

    2015-12-15

    For a fire safety analysis, in order to comply with nuclear safety goals, a nuclear fuel facility operator has to define the elements important for safety to be maintained, even in the case of a fire. One of the key points of this fire analysis is the assessment of possible fire scenarios in the facility. This paper presents the IRSN method applied to a case study to assess fire scenarios which have the most harmful effects on safety targets. The layout consists in a central room (fire cell) containing three glove boxes with radioactive material and three electrical cabinets. This room is linked to two connecting compartments (the fire cell and these two compartments define the containment cell) and then to two corridors. Each room is equipped with a mechanical ventilation system, and a pressure cascade is established from the corridors to the central room. A fire scenario was studied with fire ignition occurring in an electrical cabinet. This scenario has a set of safety goals (prevention of fire cell and containment device failure, propagation of the fire). This case study was conducted with the IRSN code SYLVIA based on two zones modelling. Safety goals were associated with key parameters and performance criteria to be fulfilled. Modelling assumptions were defined in order to maximize physical effects of the fire. Sensitivity studies were also conducted on key parameters such as oxygen limitation, equivalent-fuel definition. Eventually, a critical analysis of the code models was carried out.

  11. Overview of the applications of cement-based immobilization technologies developed at US DOE facilities

    International Nuclear Information System (INIS)

    Dole, L.R.

    1985-01-01

    This paper briefly reviews seven cement-based waste form development programs at six of the US Department of Energy (DOE) sites. These sites have developed a variety of processes that range from producing 25-mm-(1-in.-) diam pellets in a glove box to producing 240-m-(800-ft-) diam grout sheets within the bedding planes of a deep shale formation. These successful applications of cement-based waste forms to the many radioactive waste streams from nuclear facilities bear witness to the flexibility and reliability of this class of immobilization materials. The US DOE sites and their programs are: (1) Oak Ridge National Laboratory (ORNL), Hydrofracture Grout; (2) Hanford, Transportable Grout Facility (TGF); (3) Savannah River Plant (SRP), Nitrate Saltcrete; (4) EG and G Idaho, Process Experimental Pilot Plant (PREPP); (5) Mound Laboratory (ML), Waste Pelletization Process; (6) ORNL, FUETAP Concretes, and (7) Rocky Flats Plant (RFP), Inert Carrier Concrete Process (ICCP). The major issues regarding the application of cement-based waste forms to radioactive waste management problems are also presented. These issues are (1) leachability, (2) radiation stability, (3) thermal stability, (4) phase complexity of the matrix, and (5) effects of the waste stream composition. A cursory review of current research in each of these areas is included along with a discussion of future trends in cement-based waste form developments and applications. 35 refs., 12 figs

  12. 46 CFR 111.81-1 - Outlet boxes and junction boxes; general.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Outlet boxes and junction boxes; general. 111.81-1... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Outlet Boxes and Junction Boxes § 111.81-1 Outlet boxes and junction boxes; general. (a) The requirements of this subpart apply to each outlet box used with a lighting...

  13. The Classroom Animal: Box Turtles.

    Science.gov (United States)

    Kramer, David C.

    1986-01-01

    Provides basic information on the anatomy, physiology, behaviors, and distribution patterns of the box turtle. Offers suggestions for the turtle's care and maintenance in a classroom environment. (ML)

  14. Nursing wound care survey: sterile and nonsterile glove choice.

    Science.gov (United States)

    Wise, L C; Hoffman, J; Grant, L; Bostrom, J

    1997-05-01

    The application of sterile and clean procedure to the practice of wound care nursing was examined. This prospective, descriptive study surveyed staff nurses regarding glove use. Seven hundred forty-three staff nurses from five health care agencies in the San Francisco Bay Area responded to the survey. A self-report wound care survey instrument was developed by Nursing Consortium for Research and Practice members from information adapted from the wound care literature. The questionnaire comprised 31 questions and required approximately 10 minutes to complete. Nursing Consortium for Research and Practice members obtained approval from their respective institutional human subjects committees and distributed questionnaires among all nurses engaged in direct care. Some agency representatives personally handed the survey instruments to subjects, but most distributed them through their agencies personnel mailing systems. Seven hundred twenty-three (38%) of 1900 questionnaires were completed and returned to the five site coordinators. Differences were found between acute care and home health nurses. Acute care nurses were more likely than home care nurses to use sterile gloves in all wound care situations. Greater variation was found with regard to sterile technique in wound care practice than in previously reported studies. Although patient risk factors and wound type significantly influenced the choice of sterile or clean gloves, additional environmental and personal factors exerted considerable influence. These included health care setting, degree of professional education, and nurses' experiential background. Attempts to modify practice through policy change alone may not be sufficient to overcome resistance to change. Instead, it may be necessary for nurses to "unlearn" lessons from basic nursing education before they can adopt to new practices and clinical policies.

  15. Test procedure for boxed waste assay system

    International Nuclear Information System (INIS)

    Wachter, J.

    1994-01-01

    This document, prepared by Los Alamos National Laboratory's NMT-4 group, details the test methodology and requirements for Acceptance/Qualification testing of a Boxed Waste Assay System (BWAS) designed and constructed by Pajarito Scientific Corporation. Testing of the BWAS at the Plutonium Facility (TA55) at Los Alamos National Laboratory will be performed to ascertain system adherence to procurement specification requirements. The test program shall include demonstration of conveyor handling capabilities, gamma ray energy analysis, and imaging passive/active neutron accuracy and sensitivity. Integral to these functions is the system's embedded operating and data reduction software

  16. A new method of ergonomic testing of gloves protecting against cuts and stabs during knife use.

    Science.gov (United States)

    Irzmańska, Emilia; Tokarski, Tomasz

    2017-05-01

    The paper presents a new method of ergonomic evaluation of gloves protecting against cuts and stabs during knife use, consisting of five manual dexterity tests. Two of them were selected based on the available literature and relevant safety standards, and three were developed by the authors. All of the tests were designed to simulate occupational tasks associated with meat processing as performed by the gloved hand in actual workplaces. The tests involved the three most common types of protective gloves (knitted gloves made of a coverspun yarn, metal mesh gloves, and metal mesh gloves with an ergonomic polyurethane tightener) and were conducted on a group of 20 males. The loading on the muscles of the upper limb (adductor pollicis, flexor carpi ulnaris, flexor carpi radialis, and biceps brachii) was measured using surface electromyography. For the obtained muscle activity values, correlations were found between the glove type and loading of the upper limb. ANOVA showed that the activity of all muscles differed significantly between the five tests. A relationship between glove types and electromyographic results was confirmed at a significance level of α = 0.05. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Content of Asthmagen Natural Rubber Latex Allergens in Commercial Disposable Gloves.

    Science.gov (United States)

    Bittner, C; Garrido, M V; Krach, L H; Harth, V

    The use of natural rubber latex (NRL) gloves in many occupations may lead to latex sensitization, allergic asthma, and skin reactions. Due to their good properties and environmental safety NRL gloves are still being used in the healthcare setting, but also in the food industry, by hairdressers, cleaners, etc. The aim of our study was to assess the protein and NRL allergen content in commercial gloves by different methods, including a new assay. Twenty commercially available NRL gloves were analyzed. Protein extraction was performed according to the international standard ASTM D-5712. Total protein content was measured with a modified Lowry method, NRL content with the CAP Inhibition Assay, the Beezhold ELISA Inhibition Assay, and an innovative ELISA with IgY-antibodies extracted from eggs of NRL-immunized hens (IgY Inhibition Assay). We found a high protein content in a range of 215.0-1304.7 μg/g in 8 out of the 20 NRL gloves. Seven of the 20 gloves were powdered, four of them with a high protein content. In gloves with high protein content, the immunological tests detected congruently high levels of NRL allergen. We conclude that a high percentage of commercially available NRL gloves still represent a risk for NRL allergy, including asthma. The modified Lowry Method allows to infer on the latex allergen content.

  18. IMMEDIATE AND DELAYED HYPERSENSITIVITY REACTIONS TO LATEX GLOVES IN A DENTAL STUDENT. A case report.

    Directory of Open Access Journals (Sweden)

    Iliyana Stoeva

    2011-08-01

    Full Text Available The article presents a case of dental student with immediate and delayed hypersensitivity reaction to latex gloves. Symptoms appeared during the second year of regularly using of latex gloves. The student was with no history of allergies and no previous exposure to latex products.

  19. Gloves and dermal exposure to chemicals: Proposals for evaluating workplace effectiveness

    NARCIS (Netherlands)

    Cherrie, J.W.; Semple, S.; Brouwer, D.

    2004-01-01

    There are standardized laboratory tests for chemical protective gloves that provide estimates of breakthrough time and steady-state permeation flux. However, there is evidence to suggest that these tests may not be completely relevant to glove usage in the workplace. There is no consensus about how

  20. Influence of Glove Type on Mobility Performance for Wheelchair Rugby Players

    NARCIS (Netherlands)

    Mason, Barry S.; van der Woude, L. H. V.; Goosey-Tolfrey, V. L.

    Objective: The purpose of this study was to determine the effectiveness of different glove types on mobility performance in a series of field tests specific to wheelchair rugby. Design: Ten international wheelchair rugby players performed three drills in each glove condition: (i) players' current

  1. The Influence of Glove Type on Simulated Wheelchair Racing Propulsion: A Pilot Study.

    Science.gov (United States)

    Rice, I; Dysterheft, J; Bleakney, A W; Cooper, R A

    2016-01-01

    Our purpose was to examine the influence of glove type on kinetic and spatiotemporal parameters at the handrim in elite wheelchair racers. Elite wheelchair racers (n=9) propelled on a dynamometer in their own racing chairs with a force and moment sensing wheel attached. Racers propelled at 3 steady state speeds (5.36, 6.26 & 7.60 m/s) and performed one maximal effort sprint with 2 different glove types (soft & solid). Peak resultant force, peak torque, impulse, contact angle, braking torque, push time, velocity, and stroke frequency were recorded for steady state and sprint conditions. Multiple nonparametric Wilcoxon matched pair's tests were used to detect differences between glove types, while effect sizes were calculated based on Cohen's d. During steady state trials, racers propelled faster, using more strokes and larger contact angle, while applying less impulse with solid gloves compared to soft gloves. During the sprint condition, racers achieved greater top end velocities, applying larger peak force, with less braking torque with solid gloves compared to soft gloves. Use of solid gloves may provide some performance benefits to wheelchair racers during steady state and top end velocity conditions. © Georg Thieme Verlag KG Stuttgart · New York.

  2. A prospective study on the risk of glove fingertip contamination during draping in joint replacement surgery.

    Science.gov (United States)

    Makki, D; Deierl, K; Pandit, A; Trakru, S

    2014-09-01

    The aim of this prospective study was to investigate the risk of contamination of surgical gloves during preparation and draping in joint replacement surgery. During 46 hip and knee replacement procedures, the gloves of orthopaedic consultants (n=5) and registrars (n=3) were assessed for contamination immediately after draping by impression of gloved fingers on blood agar. Contamination was evaluated by the surgeon's grade, the type of procedure, the role of the assistant and the dominance of the hand. A total of 125 pairs of top gloves were examined (79 pairs from registrars and 46 pairs from consultants). Bacterial contamination was isolated on 19 pairs (15.2%) (16 pairs from registrars and 3 pairs from consultants, p=0.04). Coagulase negative staphylococci were the main isolates and contamination was considered low in all cases (1-5 colonies). Contamination was seen more on the dominant hand (16 gloves from dominant hands and 6 from non-dominant hands, p=0.04), on the index finger and thumb. More contaminated gloves were seen in hip arthroplasty procedures (16 pairs from total hip replacements vs 3 pairs from total knee replacements, p=0.02). Contamination of glove fingertips during draping in joint replacement procedures is more likely to occur among junior surgeons, in hip rather than knee arthroplasty procedures and on the dominant hand. It is therefore essential that surgeons of different grades replace gloves used in draping to avoid exposing patients to the risk of infection.

  3. Acsys in a box

    International Nuclear Information System (INIS)

    Briegel, C.; Finstrom, D.; Hendricks, B.; King, C.; Lackey, S.; Neswold, R.; Nicklaus, D.; Patrick, J.; Petrov, A.; Rechenmacher, R.; Schumann, C.; Smedinghoff, J.

    2012-01-01

    The Accelerator Control System (ACSYS) at Fermilab has evolved to enable this relatively large control system to be encapsulated into a 'box' such as a laptop. The goal was to provide a platform isolated from the 'online' control system. This platform can be used internally for making major upgrades and modifications without impacting operations. It also provides a stand-alone environment for research and development including a turnkey control system for collaborators. Over time, the code base running on Scientific Linux has enabled all the salient features of the Fermilab's control system to be captured in an off-the-shelf laptop. The anticipated additional benefits of packaging the system include improved maintenance, reliability, documentation, and future enhancements. (authors)

  4. ACYSYS in a box

    Energy Technology Data Exchange (ETDEWEB)

    Briegel, C.; Finstrom, D.; Hendricks, B.; King, C.; Lackey, S.; Neswold, R.; Nicklaus, D.; Patrick, J.; Petrov, A.; Rechenmacher, R.; Schumann, C.; /Fermilab

    2011-11-01

    The Accelerator Control System at Fermilab has evolved to enable this relatively large control system to be encapsulated into a 'box' such as a laptop. The goal was to provide a platform isolated from the 'online' control system. This platform can be used internally for making major upgrades and modifications without impacting operations. It also provides a standalone environment for research and development including a turnkey control system for collaborators. Over time, the code base running on Scientific Linux has enabled all the salient features of the Fermilab's control system to be captured in an off-the-shelf laptop. The anticipated additional benefits of packaging the system include improved maintenance, reliability, documentation, and future enhancements.

  5. The Potential of Wearable Sensor Technology for EVA Glove Ergonomic Evaluation

    Science.gov (United States)

    Reid, Christopher R.; McFarland, Shane; Norcross, Jason R.; Rajulu, Sudhakar

    2014-01-01

    Injuries to the hands are common among astronauts who train for extravehicular activity (EVA). Many of these injuries refer to the gloves worn during EVA as the root cause. While pressurized, the bladder and outer material of these gloves restrict movement and create pressure points while performing tasks, sometimes resulting in pain, muscle fatigue, abrasions, and occasionally a more severe injury, onycholysis (fingernail delamination). The most common injury causes are glove contact (pressure point/rubbing), ill-fitting gloves, and/or performing EVA tasks in pressurized gloves. A brief review of the Lifetime Surveillance of Astronaut Health's injury database reveals over 57% of the total injuries to the upper extremities during EVA training occurred either to the metacarpophalangeal (MCP) joint, fingernail, or the fingertip. Twenty-five of these injuries resulted in a diagnosis of onycholysis

  6. Bacterial contamination of surgeons' gloves during shunt insertion; a pilot study

    DEFF Research Database (Denmark)

    Sørensen, Preben; Ejlertsen, Tove; Aaen, Dorte

    2008-01-01

    antibiotics and double gloving, by surgeons experienced in shunt surgery. Surgical incision, dissection and tunnelling were done. Then the surgeon, the scrub-nurse and, in three cases, the assistant made an imprint of their outer gloves on agar plates. Hereafter, they changed the outer pair of gloves before...... handling the shunt and completing the operation. The plates were cultured for 6 days in both aerobic and anaerobic environment. In all cases the surgeons gloves were contaminated, and in six cases also the nurses' gloves were contaminated, as well as all three assistants. Propionebacterium acnes were...... nurse and assistant were contaminated with micro-organisms less than 15 min after surgery has been commenced and before the shunts were handled. This study offers a feasible, simple and logical explanation of how shunts may become contaminated and infected. A simple measure would be to change the outer...

  7. Prospective data collection and analysis of perforations and tears of latex surgical gloves during primary endoprosthetic surgeries

    Directory of Open Access Journals (Sweden)

    Zaatreh, Sarah

    2016-12-01

    Full Text Available Introduction: Surgical gloves are used to prevent contamination of the patient and the hospital staff with pathogens. The aim of this study was to examine the actual effectiveness of gloves by examining the damage (perforations, tears to latex gloves during surgery in the case of primary hip and knee prosthesis implantation. Materials and methods: Latex surgical gloves used by surgeons for primary hip and knee replacement surgeries were collected directly after the surgery and tested using the watertightness test according to ISO EN 455-1:2000.Results: 540 gloves were collected from 104 surgeries. In 32.7% of surgeries at least one glove was damaged. Of all the gloves collected, 10.9% were damaged, mainly on the index finger. The size of the perforations ranged from ≤1 mm to over 5 mm. The surgeon’s glove size was the only factor that significantly influenced the occurrence of glove damage. Surgeon training level, procedure duration, and the use of bone cement had no significant influence.Conclusions: Our results highlight the high failure rate of surgical gloves. This has acute implications for glove production, surgical practice, and hygiene guidelines. Further studies are needed to detect the surgical steps, surface structures, and instruments that pose an increased risk for glove damage.

  8. Prospective data collection and analysis of perforations and tears of latex surgical gloves during primary endoprosthetic surgeries

    Science.gov (United States)

    Zaatreh, Sarah; Enz, Andreas; Klinder, Annett; König, Tony; Mittelmeier, Lena; Kundt, Günther; Mittelmeier, Wolfram

    2016-01-01

    Introduction: Surgical gloves are used to prevent contamination of the patient and the hospital staff with pathogens. The aim of this study was to examine the actual effectiveness of gloves by examining the damage (perforations, tears) to latex gloves during surgery in the case of primary hip and knee prosthesis implantation. Materials and methods: Latex surgical gloves used by surgeons for primary hip and knee replacement surgeries were collected directly after the surgery and tested using the watertightness test according to ISO EN 455-1:2000. Results: 540 gloves were collected from 104 surgeries. In 32.7% of surgeries at least one glove was damaged. Of all the gloves collected, 10.9% were damaged, mainly on the index finger. The size of the perforations ranged from ≤1 mm to over 5 mm. The surgeon’s glove size was the only factor that significantly influenced the occurrence of glove damage. Surgeon training level, procedure duration, and the use of bone cement had no significant influence. Conclusions: Our results highlight the high failure rate of surgical gloves. This has acute implications for glove production, surgical practice, and hygiene guidelines. Further studies are needed to detect the surgical steps, surface structures, and instruments that pose an increased risk for glove damage. PMID:28066701

  9. Seismic vulnerability assessment of a continuous steel box girder ...

    Indian Academy of Sciences (India)

    Bridges are one of the most crucial facilities of transportation networks. Therefore, evaluation of the seismic vulnerability of bridge structures is perpetually regarded topic for researchers. In this study, we developed seismic fragility curves for a continuous steel box girder bridge considering the effect of differentlevels of ...

  10. What Makes a Better Box?

    Science.gov (United States)

    Moyer, Richard; Everett, Susan

    2010-01-01

    Every morning, many Americans start their day with a bowl of cereal. Some spend time while they eat breakfast reading the back of the cereal box, but few consider its size, shape, and construction, or realize that it was designed by an engineer. This article describes a lesson in which students design, build, and critique cereal boxes. The lesson…

  11. Spirit Boxes: Expressions of Culture.

    Science.gov (United States)

    DeMuro, Ted

    1984-01-01

    After studying the culture and art of the ancient civilizations of South America, Mesopotamia, Greece, and Egypt, secondary level art students made spirit boxes as expressions of the various cultures. How to make the boxes and how to prepare the face molds are described. (RM)

  12. Seal boxes from the Viminacium site

    Directory of Open Access Journals (Sweden)

    Milovanović Bebina

    2013-01-01

    Full Text Available Bronze seal boxes that had the function of holding the wax seal on the Viminacium site - Upper Moesia (Stari Kostolac, Serbia, mainly from the area of the necropolis (ten were found in the graves and ten at the cemetery between the graves. Six are from buildings that had a storage function, five are from public facilities - an amphitheatre, and only one find is from the military fort of the legion VII Claudia, which was stationed in Viminacium in the second half of the 1st century. Thirty-two seal boxes have been processed: nine whole, six with fragmented upper and lower parts, seven bases and ten covers. Seal boxes consist of two parts: the cover and the base. The cover is decorated with figural images, concentric rings and especially with applied ornaments. Some of the motifs are filled with enamel. The base always has three to five circular perforations at the bottom, the side walls are a height of 4 to 5 mm with two opposed notches or slots which are thought to have facilitated the tying of the seal box to a package or a document. The lock mechanism is operated using the hinges principle. Some specimens have a circular extension on the cover with a thorn on the bottom. This fits the hollow in the base, through which passes a thorn for the additional fixing of the cover. Based on shape and decoration, seal boxes were classified into five types: I - elliptical or oval shaped with a figural representation on the cover derived in relief; II/1 - leaf or heart-shaped with a special, riveted ornament; II/2 - leaf or heart-shaped with enamel on the cover; III/1 - circular showing a form in relief; III/2 - circular with cast concentric rings, with no enamel; III/3 - circular with concentric rings with enamel on the cover; IV - diamond shaped with enamel on the cover and V - square with enamel on the cover. The seal boxes dominate chronologically from the first half of the 2nd and throughout the 3rd century.

  13. Spacesuit Glove-Induced Hand Trauma and Analysis of Potentially Related Risk Variables

    Science.gov (United States)

    Charvat, Chacqueline M.; Norcross, Jason; Reid, Christopher R.; McFarland, Shane M.

    2015-01-01

    Injuries to the hands are common among astronauts who train for extravehicular activity (EVA). When the gloves are pressurized, they restrict movement and create pressure points during tasks, sometimes resulting in pain, muscle fatigue, abrasions, and occasionally more severe injuries such as onycholysis. Glove injuries, both anecdotal and recorded, have been reported during EVA training and flight persistently through NASA's history regardless of mission or glove model. Theories as to causation such as glove-hand fit are common but often lacking in supporting evidence. Previous statistical analysis has evaluated onycholysis in the context of crew anthropometry only. The purpose of this study was to analyze all injuries (as documented in the medical records) and available risk factor variables with the goal to determine engineering and operational controls that may reduce hand injuries due to the EVA glove in the future. A literature review and data mining study were conducted between 2012 and 2014. This study included 179 US NASA crew who trained or completed an EVA between 1981 and 2010 (crossing both Shuttle and ISS eras) and wore either the 4000 Series or Phase VI glove during Extravehicular Mobility Unit (EMU) spacesuit EVA training and flight. All injuries recorded in medical records were analyzed in their association to candidate risk factor variables. Those risk factor variables included demographic characteristics, hand anthropometry, glove fit characteristics, and training/EVA characteristics. Utilizing literature, medical records and anecdotal causation comments recorded in crewmember injury data, investigators were able to identify several risk factors associated with increased risk of glove related injuries. Prime among them were smaller hand anthropometry, duration of individual suited exposures, and improper glove-hand fit as calculated by the difference in the anthropometry middle finger length compared to the baseline EVA glove middle finger length.

  14. How do gloves affect cutaneous sensibility in medical practice? Two new applied tests.

    Science.gov (United States)

    Mylon, Peter; Carré, Matt J; Martin, Nicolas; Lewis, Roger

    2017-01-01

    In order to quantify the effect of medical gloves on tactile performance, two new Simulated Medical Examination Tactile Tests (SMETT) have been developed to replicate the tactile and haptic ability required in medical examinations: the 'Bumps' test and the 'Princess and the Pea' (P&P) test. A pilot study was carried out using 30-40 subjects for each test in order to investigate the suitability of the tests for medical glove evaluation. Tests were performed with latex and nitrile examination gloves and without gloves. Following the tests, small-scale studies were carried out to investigate the effect of various design parameters, such as material stiffness and tactile exploration method. In the 'Bumps' test, subjects performed significantly better in the ungloved condition, and there were 'almost significant' differences between the gloves, with the thinner latex gloves performing better than the thicker nitrile gloves. Both finger orientation and surface lubrication were found to have a significant effect on results, indicating that these need to be clearly defined in the test procedure. In the 'P&P' test, no significant effect of hand condition was found, suggesting that haptic sensing is less affected by medical gloves than cutaneous sensibility. Other factors such as material stiffness, technique and test orientation had a more significant effect. The SMETT 'Bumps' test has potential as a clinical manual performance evaluation tool and may be used to evaluate the relative effects of different gloves. The SMETT 'P&P' test is a valid measure of haptic or tactile performance, but should not be used in glove evaluation. Both tests could have further applications, such as in the assessment of neurological impairment or aptitude testing for potential surgeons.

  15. Computational Analysis of the G-III Laminar Flow Glove

    Science.gov (United States)

    Malik, Mujeeb R.; Liao, Wei; Lee-Rausch, Elizabeth M.; Li, Fei; Choudhari, Meelan M.; Chang, Chau-Lyan

    2011-01-01

    Under NASA's Environmentally Responsible Aviation Project, flight experiments are planned with the primary objective of demonstrating the Discrete Roughness Elements (DRE) technology for passive laminar flow control at chord Reynolds numbers relevant to transport aircraft. In this paper, we present a preliminary computational assessment of the Gulfstream-III (G-III) aircraft wing-glove designed to attain natural laminar flow for the leading-edge sweep angle of 34.6deg. Analysis for a flight Mach number of 0.75 shows that it should be possible to achieve natural laminar flow for twice the transition Reynolds number ever achieved at this sweep angle. However, the wing-glove needs to be redesigned to effectively demonstrate passive laminar flow control using DREs. As a by-product of the computational assessment, effect of surface curvature on stationary crossflow disturbances is found to be strongly stabilizing for the current design, and it is suggested that convex surface curvature could be used as a control parameter for natural laminar flow design, provided transition occurs via stationary crossflow disturbances.

  16. Experimental study on the drying of natural latex medical gloves

    Science.gov (United States)

    Chankrachang, Mano; Yongyingsakthavorn, Pisit; Tohsan, Atitaya; Nontakaew, Udomkiat

    2018-01-01

    The purpose of this research was to study latex film drying at 70 °C using a laboratory drying oven. Two different total solid content (TSC) latex compounds, which 45% TSC and 35% TSC were used. The undried latex films were prepared according to the common procedures used in latex gloves manufacturers, that is, by dry coagulant dipping process. The experimental results such as initial moisture content, the amount of moisture and drying time of latex films in each latex compound formula were determined. After that, the results were projected to calculate on the production capacity expand by 1 million piece/day of natural latex medical gloves. Finally, the rate of moisture entering the latex drying oven and the energy consumption of the drying oven were estimated. The results indicated that when the 35% TSC of latex compound was used. The initial moisture content of latex film was higher than 45% TSC of latex compound about 7%. The drying time of 35% TSC was longer than 45% TSC for 2.5 min and consume more energy about 10%. As a result, the 45% TSC latex compound was the better way to saving energy and managing humidity in the production line. Therefore, it was found to very useful to an approximate design length and size of actual of latex drying oven and the rate of moisture entering the oven as well.

  17. Gestural Interaction for Virtual Reality Environments through Data Gloves

    Directory of Open Access Journals (Sweden)

    G. Rodriguez

    2017-05-01

    Full Text Available In virtual environments, virtual hand interactions play a key role in interactivity and realism allowing to perform fine motions. Data glove is widely used in Virtual Reality (VR and through simulating a human hands natural anatomy (Avatar’s hands in its appearance and motion is possible to interact with the environment and virtual objects. Recently, hand gestures are considered as one of the most meaningful and expressive signals. As consequence, this paper explores the use of hand gestures as a mean of Human-Computer Interaction (HCI for VR applications through data gloves. Using a hand gesture recognition and tracking method, accurate and real-time interactive performance can be obtained. To verify the effectiveness and usability of the system, an experiment of ease learning based on execution’s time was performed. The experimental results demonstrate that this interaction’s approach does not present problems for people more experienced in the use of computer applications. While people with basic knowledge has some problems the system becomes easy to use with practice.

  18. Using the Space Glove to Teach Spatial Thinking

    Science.gov (United States)

    Lord, Peter

    2008-01-01

    The challenge of extending students' skills in spatial thinking to astronomical scales was the central focus of our K-8 curriculum development. When the project's lead teacher requested a curriculum that cumulatively built on each prior year's learning in a spiral fashion, I knew exactly what the school was asking for. Second and third graders began by noticing the cyclical patters that the sun, moon, and stars make in the sky. Fourth graders explored the phases of the moon by taking turns modeling and sketching them in their classroom and then comparing them to the real sky. Sixth !graders used real telescopes to observe a moving model of our solar system and walked a scale model of the planets' orbits. The curriculum is designed to expand students' capacity to visualize space in a hierarchical fashion that asks them to imagine themselves from a broader number of spatial perspectives through hands-on activities. The "situational awareness" Peter's story describes is a hallmark of high-performance engineering and innovation. Keeping in mind the potential outcomes of multiple paths of pursuit from multiple perspectives while keeping track of their relative merits and performance requirements is a demanding spatial task. What made it possible for Peter to transform the failure of his first glove into triumph was the mental space in which that failure provided exactly the information needed for a new breakthrough. In at least two cases, Peter could immediately "see" the full implications of what his hands were telling him. He tells the story of how putting his hands in a Phase VI astronaut glove instantly transformed his understanding of the glove challenge. Six months into his development, the failure of circumferentially wrapped cords to produce a sufficiently flexible glove again forced him to abandon his assumptions. His situational awareness was so clear and compelling it became a gut-level response. Peter's finely developed spatial skills enabled him to almost

  19. Learning Intelligent Dialogs for Bounding Box Annotation

    OpenAIRE

    Konyushkova, Ksenia; Uijlings, Jasper; Lampert, Christoph; Ferrari, Vittorio

    2017-01-01

    We introduce Intelligent Annotation Dialogs for bounding box annotation. We train an agent to automatically choose a sequence of actions for a human annotator to produce a bounding box in a minimal amount of time. Specifically, we consider two actions: box verification [37], where the annotator verifies a box generated by an object detector, and manual box drawing. We explore two kinds of agents, one based on predicting the probability that a box will be positively verified, and the other bas...

  20. Disposable gendine antimicrobial gloves for preventing transmission of pathogens in health care settings.

    Science.gov (United States)

    Reitzel, Ruth; Rosenblatt, Joel; Jiang, Ying; Hachem, Ray; Raad, Issam

    2014-01-01

    Transmission of organisms by contact of gloves with surfaces following contact with a pathogen source has been recognized as an important vector for pathogenesis of health care-associated infections. In these cases, the gloves protect the wearer from contact with the pathogenic organisms; however, this personal protection can facilitate the wearer unwittingly becoming a carrier of the pathogens from one location to another. A novel gendine (combination of chlorhexidine and gentian violet) antiseptic coating for the external surface of the glove was developed as a potential intervention to prevent this mode of transmission. We characterized the ability of the coating to rapidly kill bacterial and fungal pathogens within 1 minute of contact with the glove surface. The International Organization of Standardization 22196 concentrated inoculum contact testing methodology was followed. The gendine-coated gloves were able to fully eradicate multidrug-resistant organisms included methicillin-resistant Staphylococcus aureus, vancomycin-resistant enterocci, multidrug-resistant Pseudomonas aeruginosa, and Klebsiella pneumoniae carbapenemase producing. In addition, Candida albicans, Candida glabarata, and 2 pathogenic Escherichia coli strains commonly associated with invasive gastroenteritis were also fully eradicated within 1 minute of contact. The gendine coating did not adversely impact the finish or integrity of the disposable gloves. The highly efficacious gendine-coated antimicrobial gloves potentially provide an additional means of protection against horizontal transmission of common pathogens in a hospital setting. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  1. Analysis of Asymmetric Aircraft Aerodynamics Due to an Experimental Wing Glove

    Science.gov (United States)

    Hartshorn, Fletcher

    2011-01-01

    Aerodynamic analysis on a business jet with a wing glove attached to one wing is presented and discussed. If a wing glove is placed over a portion of one wing, there will be asymmetries in the aircraft as well as overall changes in the forces and moments acting on the aircraft. These changes, referred to as deltas, need to be determined and quantified to make sure the wing glove does not have a drastic effect on the aircraft flight characteristics. TRANAIR, a non-linear full potential solver was used to analyze a full aircraft, with and without a glove, at a variety of flight conditions and angles of attack and sideslip. Changes in the aircraft lift, drag and side force, along with roll, pitch and yawing moment are presented. Span lift and moment distributions are also presented for a more detailed look at the effects of the glove on the aircraft. Aerodynamic flow phenomena due to the addition of the glove and its fairing are discussed. Results show that the glove used here does not present a drastic change in forces and moments on the aircraft, but an added torsional moment around the quarter-chord of the wing may be a cause for some structural concerns.

  2. A comparison of the effect of different surgical gloves on objective measurement of fingertip cutaneous sensibility

    Science.gov (United States)

    Bucknor, A; Karthikesalingam, A; Markar, SR; Holt, PJ; Jones, I; Allen-Mersh, TG

    2010-01-01

    INTRODUCTION The prudent selection of surgical gloves can deliver significant efficiency savings. However, objective data are lacking to compare differences in cutaneous sensibility between competing gloves. Therefore, the present study examined the use of a single comparable model of sterile surgical glove from two competing providers, Gammex PF HyGrip® (Ansell Limited, Red Bank, NJ, USA) with Biogel® (Mölnlycke Health Care AB, Göteborg, Sweden). SUBJECTS AND METHODS Cutaneous pressure threshold, static and moving two-point discrimination were measured as indices of objective surgical glove performance in 52 blinded healthcare professionals. RESULTS The mean cutaneous pressure threshold was 0.0680 ± 0.0923 g for skin, 0.411 ± 0.661 g for Ansell gloves and 0.472 ± 0.768 g for Biogel gloves. Skin was significantly more sensitive than Ansell (Psensibility and two-point discrimination. However, a difference in subjective preference was noted. Untested factors may underlie this discrepancy, and further research should employ more sophisticated measurements of surgical performance using competing models of surgical glove. PMID:21118618

  3. Microclimate boxes for panel paintings

    DEFF Research Database (Denmark)

    Wadum, Jørgen

    1998-01-01

    The use of microclimate boxes to protect vulnerable panel paintings is, therefore, not a new phenomenon of the past two or three decades. Rather, it has been a concern for conservators and curators to protect these objects of art at home and in transit since the end of the nineteenth century....... The increased number of travelling exhibitions in recent years has heightened the need to protect paintings during circulation (Thomson 1961; Mecklenburg 1991). The use and design of microclimate boxes have been evolving since 1892. These boxes may be divided into three broad groups: those using an active...

  4. Transuranic (Tru) waste volume reduction operations at a plutonium facility

    Energy Technology Data Exchange (ETDEWEB)

    Cournoyer, Michael E [Los Alamos National Laboratory; Nixon, Archie E [Los Alamos National Laboratory; Dodge, Robert L [Los Alamos National Laboratory; Fife, Keith W [Los Alamos National Laboratory; Sandoval, Arnold M [Los Alamos National Laboratory; Garcia, Vincent E [Los Alamos National Laboratory

    2010-01-01

    Programmatic operations at the Los Alamos National Laboratory Plutonium Facility (TA 55) involve working with various amounts of plutonium and other highly toxic, alpha-emitting materials. The spread of radiological contamination on surfaces, airborne contamination, and excursions of contaminants into the operator's breathing zone are prevented through use of a variety of gloveboxes (the glovebox, coupled with an adequate negative pressure gradient, provides primary confinement). Size-reduction operations on glovebox equipment are a common activity when a process has been discontinued and the room is being modified to support a new customer. The Actin ide Processing Group at TA-55 uses one-meter-long glass columns to process plutonium. Disposal of used columns is a challenge, since they must be size-reduced to get them out of the glovebox. The task is a high-risk operation because the glass shards that are generated can puncture the bag-out bags, leather protectors, glovebox gloves, and the worker's skin when completing the task. One of the Lessons Learned from these operations is that Laboratory management should critically evaluate each hazard and provide more effective measures to prevent personnel injury. A bag made of puncture-resistant material was one of these enhanced controls. We have investigated the effectiveness of these bags and have found that they safely and effectively permit glass objects to be reduced to small pieces with a plastic or rubber mallet; the waste can then be easily poured into a container for removal from the glove box as non-compactable transuranic (TRU) waste. This size-reduction operation reduces solid TRU waste generation by almost 2% times. Replacing one-time-use bag-out bags with multiple-use glass crushing bags also contributes to reducing generated waste. In addition, significant costs from contamination, cleanup, and preparation of incident documentation are avoided. This effort contributes to the Los Alamos

  5. Decontamination and demolition of a former plutonium processing facility's process exhaust system, firescreen, and filter plenum buildings

    International Nuclear Information System (INIS)

    LaFrate, P.J. Jr.; Stout, D.S.; Elliott, J.W.

    1996-01-01

    The Los Alamos National Laboratory (LANL) Decommissioning Project has decontaminated, demolished, and decommissioned a process exhaust system, two filter plenum buildings, and a firescreen plenum structure at Technical Area 21 (TA-21). The project began in August 1995 and was completed in January 1996. These high-efficiency particulate air (HEPA) filter plenums and associated ventilation ductwork provided process exhaust to fume hoods and glove boxes in TA-21 Buildings 2 through 5 when these buildings were active plutonium and uranium processing and research facilities. This paper summarizes the history of TA-21 plutonium and uranium processing and research activities and provides a detailed discussion of integrated work process controls, characterize-as-you-go methodology, unique engineering controls, decontamination techniques, demolition methodology, waste minimization, and volume reduction. Also presented in detail are the challenges facing the LANL Decommissioning Project to safely and economically decontaminate and demolish surplus facilities and the unique solutions to tough problems. This paper also shows the effectiveness of the integrated work package concept to control work through all phases

  6. Decontamination and demolition of a former plutonium processing facility's process exhaust system, firescreen, and filter plenum buildings

    International Nuclear Information System (INIS)

    LaFrate, P.J. Jr.; Stout, D.S.; Elliott, J.W.

    1996-01-01

    The Los Alamos National Laboratory (LANL) Decommissioning Project has decontaminated, demolished, and decommissioned a process exhaust system, two filter plenum buildings, and a firescreen plenum structure at Technical Area 21 (TA-2 1). The project began in August 1995 and was completed in January 1996. These high-efficiency particulate air (HEPA) filter plenums and associated ventilation ductwork provided process exhaust to fume hoods and glove boxes in TA-21 Buildings 2 through 5 when these buildings were active plutonium and uranium processing and research facilities. This paper summarizes the history of TA-21 plutonium and uranium processing and research activities and provides a detailed discussion of integrated work process controls, characterize-as-you-go methodology, unique engineering controls, decontamination techniques, demolition methodology, waste minimization, and volume reduction. Also presented in detail are the challenges facing the LANL Decommissioning Project to safely and economically decontaminate and demolish surplus facilities and the unique solutions to tough problems. This paper also shows the effectiveness of the integrated work package concept to control work through all phases

  7. DIRECT KICKS IN BOXING

    Directory of Open Access Journals (Sweden)

    Izet Kahrović

    2009-11-01

    Full Text Available Hit directly, giving any impact maximum muscle strength is skill, and it is neces- sary to the exercise and learning to make it perfect. Training begins with oral statement, so that students get to know with the techni- que that works. After oral exposure, it is necessary to create a good notion on technology that is adopted. The best way for the creation of good notion is a good demonstration. In direct training kicks in the box, you need patience and gradualness and there- fore uses a large number of additional exercises. In their work with beginners, in the first class, individual elements of technology, and also direct blow, it is necessary to separate the parts and run them on multiple commands, to later come to the confluence in one command. Direct wounds, with left and right hand, can be run from the towns, on the head and body, from the movement, to step forward, step back and step aside, the remedy to the left and right side. Left direct is taking out from a running protrusion hands, but kick, which is a pro- duct of the system, ankle-knee-pelvis and shoulder forward horizontaly. Set at the time of stripes, body weight over the left leg. Right direct from the place, starting ekscentrical reflecsive impuls of a extensor muscle in ankle, knee and joint of a hip.This kind of a sud- den movement is running simultaneously with the rotation of the body around vertical (longitudinal axis, with the transfer body weight on the left leg. Further movement to the hand which serves as a lever, which is transmitted through the power stroke

  8. A permanently magnetized high gradient magnetic filter for glove-box cleaning and increasing HEPA filter life

    International Nuclear Information System (INIS)

    Watson, J.H.P.; Boorman, C.H.

    1991-01-01

    The purpose of this paper is to describe the structure and testing of a permanently magnetized magnetic filter on simulants for radioactive material. The experimental work was carried out at British Nuclear Fuels plc, Sellafield, England and in CEN/SCK, Mol, Belgium using Cr powder which is a good magnetic simulant for PuO 2 . The basis of the use of such a filter in the nuclear industry relies on the fact that much of the radioactive material is paramagnetic. In the last twenty years a separation technique has been developed which allows weakly paramagnetic particles of colloidal size to be separated from fluid which passes through the separator. This method is called high gradient magnetic separation (HGMS) and is accomplished by magnetizing a fine ferromagnetic wire matrix by an externally applied magnetic field. This paper describes a new approach to this problem, by using a magnetically hysteretic material to construct the ferromagnetic matrix, it has been possible to provide a magnetic field in the region of the matrix and also have a residual magnetization within the matrix. This provides extremely compact magnetic separation systems. There are some subtle differences between this separation system and conventional HGMS which makes the radial feed system, with all its advantages, almost mandatory for hysteretic HGMS

  9. e of the Surgical Glove in Modified Vacuum-Assisted Wound Healing

    Directory of Open Access Journals (Sweden)

    Shankar Ram Hemmanur

    2013-09-01

    Full Text Available Vacuum-assisted wound healing has been proven to be more efficacious than conventionaldressings. Vacuum dressing has been frequently modified given the restrictions in resourcesavailable. Here we present a modified method of vacuum dressing by using surgical orgynaecological gloves for lower and upper limb wounds. Vacuum dressing was applied withparts of a surgical or gynaecological glove and Opsite with T-tailing of the suction outlet.Vacuum-assisted wound healing using the surgical gloves showed relatively good woundhealing in the amputation stump, finger, arm, and leg in the cases studied.

  10. Evaluation of Glove Damage during Dental Procedures among Dental Specialists in Tabriz

    Directory of Open Access Journals (Sweden)

    Saeed Nezafati

    2007-08-01

    Full Text Available

    Background and aims. Dental practitioners are prone to occupational risk of infection. This can be prevented in part by wearing gloves. However, for this to be effective, gloves should be intact during the entire course of dental procedure. Leaky surgical latex gloves have been seen in 0.9% of cases before use. As much as 1.9% of latex gloves have been reported to be damaged during dental procedures. In this study, we decided to assess glove damage during dental procedures among dental specialists in Tabriz.

    Materials and methods. Thirty-six dental specialists were selected for this study. Each practitioner received 40 pairs of intact powdered latex gloves. Upon the completion of dental procedures, the gloves were retrieved and any tears were evaluated separately for right and left hands. Data was analyzed using chi-square test.

    Results. 159 punctures were detected in 144 gloves (5% out of 2880 unpaired gloves used by practitioners. They noticed the tear(s in 60 cases (2%, however, 99 cases (3% of tear(s were not noted during the procedure. The highest rate of glove damage was observed in the prosthodontists’ group (12.3%, which was statistically significant comparing to other groups (p=0.048. The lowest rate of the damage was observed in the oral surgeons’ group (2% which showed no significant difference (p=0.134. The highest rate of punctures in the gloves was observed in the first and second fingers of the non-dominant hand.

    Conclusion. The damage to 5% of the gloves is highly significant, with a potential role in occupational hazards. The higher rate of leaks in the prosthodontists’ group compared to other groups demands for greater prudence in this field. The high rate of leaks in the first and second fingers of the non-dominant hand requires more attention to this area during daily practice.

  11. In-Situ Leak Testing And Replacement Of Glovebox Isolator, Or Containment Unit Gloves

    Science.gov (United States)

    Castro, Julio M.; Macdonald, John M.; Steckle, Jr., Warren P.

    2004-11-02

    A test plug for in-situ testing a glove installed in a glovebox is provided that uses a top plate and a base plate, and a diametrically expandable sealing mechanism fitting between the two plates. The sealing mechanism engages the base plate to diametrically expand when the variable distance between the top plate and the bottom plate is reduced. An inlet valve included on the top plate is used to introducing a pressurized gas to the interior of the glove, and a pressure gauge located on the top plate is used to monitor the interior glove pressure.

  12. Article-in-a-Box

    Indian Academy of Sciences (India)

    Volume 1 Issue 5 May 1996 pp 2-2 Article-in-a-Box. Chief Editor's column / The First Electronic Computer · V Rajaraman · More Details Fulltext PDF. Volume 1 Issue 6 June 1996 pp 2-4 Article-in-a-Box. Konrad Lorenz · Raghavendra Gadagkar · More Details Fulltext PDF. Volume 1 Issue 8 August 1996 pp 3-4 Article-in-a- ...

  13. Fuel element box inspection device

    International Nuclear Information System (INIS)

    Ortmayer, R.M.; Pick, W.

    1985-01-01

    The invention concerns a device for inspecting the outer geometry of a long fuel element box by measuring the surface contours over its longitudinal crossection and along its length by sensors. These are kept in a sledge which can be moved along the fuel element guide in a slot guide. The measurement signals reach an evaluation device outside the longitudinal box. (orig./HP) [de

  14. The development of a laser-induced photoacoustic facility for actinide speciation

    International Nuclear Information System (INIS)

    Ewart, F.T.; McMillan, J.W.; Thomason, H.P.; Liezers, M.; Pollard, P.M.

    1988-02-01

    A laser induced photoacoustic spectroscopy (LIPAS) facility has been developed at Harwell to measure actinide species in solution with the minimal disturbance of the species equilibria. The novel true dual beam system, which is based on an excimer laser driven dye laser and optical cells mounted on piezoelectric detectors, has high sensitivity and stability, and is capable of detecting Am(III) at ca 10 -8 M and Np(IV), (V) and (VI) at ca 10 -7 M. Samples can be measured in an inert atmosphere glove box which helps to maintain the anaerobic conditions expected in deep waste repositories. To date, LIPAS has been used to measure actinide species directly in solutions from waste programmes and to observe americium and neptunium species in solutions of varying Eh, pH and carbonate concentration. The information gained is being used to validate the data used in the geochemical/thermodynamic codes used to predict possible radionuclide species within a radioactive waste repository. (author)

  15. The development of a laser-induced photoacoustic facility for actinide speciation

    International Nuclear Information System (INIS)

    Ewart, F.T.; McMillan, J.W.; Pollard, P.M.; Thomason, H.P.; Liezers, M.

    1987-09-01

    A laser induced photoacoustic spectroscopy (LIPAS) facility has been developed at Harwell to measure actinide species in solution with the minimal disturbance of the species equilibria. The novel true dual beam system, which is based on an excimer laser driven dye laser and optical cells mounted on piezoelectric detectors, has high sensitivity and stability, and is capable of detecting Am(III) at ca 10 -8 M and Np(IV), (V) and (VI) at ca 10 -7 M. Samples can be measured in an inert atmosphere glove box which helps to maintain the anaerobic conditions expected in deep waste repositories. To date, LIPAS has been used to measure actinide species directly in solutions from waste programmes and to observe americium and neptunium species in solutions of varying Eh, pH and carbonate concentration. The information gained is being used to validate the data used in the geochemical/thermodynamic codes used to predict possible radionuclide species within a radioactive waste repository. (author)

  16. Qualification of box HEPA filters for nuclear applications

    International Nuclear Information System (INIS)

    Bergman, W.; Larsen, G.; Wilson, K.; Rainer, F.

    1995-03-01

    We have successfully completed qualification tests on high efficiency particulate air (HEPA) filters that are encapsulated within a box and manufactured by American Air Filters. The qualification tests are required by the American Society of Mechanical Engineers Standard ASME N509 and the U.S. Military Standard MIL-F-51068 for HEPA filters to be used in nuclear applications. The qualification tests specify minimum filter efficiencies following exposure to heated air, overpressure, and rough handling. Prior to this study, no box HEPA filters from any manufacturer had been qualified despite their wide-spread use in Department of Energy (DOE) facilities. Box HEPA filters are not addressed in any of the existing HEPA standards and only briefly discussed in the Nuclear Air Cleaning Handbook

  17. A Magnetic Resonance Compatible Soft Wearable Robotic Glove for Hand Rehabilitation and Brain Imaging.

    Science.gov (United States)

    Hong Kai Yap; Kamaldin, Nazir; Jeong Hoon Lim; Nasrallah, Fatima A; Goh, James Cho Hong; Chen-Hua Yeow

    2017-06-01

    In this paper, we present the design, fabrication and evaluation of a soft wearable robotic glove, which can be used with functional Magnetic Resonance imaging (fMRI) during the hand rehabilitation and task specific training. The soft wearable robotic glove, called MR-Glove, consists of two major components: a) a set of soft pneumatic actuators and b) a glove. The soft pneumatic actuators, which are made of silicone elastomers, generate bending motion and actuate finger joints upon pressurization. The device is MR-compatible as it contains no ferromagnetic materials and operates pneumatically. Our results show that the device did not cause artifacts to fMRI images during hand rehabilitation and task-specific exercises. This study demonstrated the possibility of using fMRI and MR-compatible soft wearable robotic device to study brain activities and motor performances during hand rehabilitation, and to unravel the functional effects of rehabilitation robotics on brain stimulation.

  18. Space Suit Glove Pressure Garment Metacarpal Joint and Robotic Hand Analysis, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Spacesuit glove pressure garments have been a design challenge for NASA since the inception of spacesuits. The human hand demands a complex range of motions, a close...

  19. Transfer efficiency of Staphylococcus aureus between nitrile exam gloves and nonporous fomites.

    Science.gov (United States)

    Koenig, David W; Korir-Morrison, Cindy; Hoffman, Douglas R

    2016-02-01

    This report describes fomite transmission of Staphylococcus aureus amongst various surfaces. A contact transfer protocol was completed to evaluate the movement of S aureus between a person wearing nitrile gloves and either: handshaking with another person with gloved hands, touching a plastic cellular telephone back, or touching a stainless steel rod. The data in this preliminary study imply that the highest bacterial transfer is with metal surfaces followed by plastic. Interestingly, glove-to-glove transfer occurred but transfered less bacteria than a plastic or metal surface. The observations from this study point to the need to clearly define hygiene behaviors to reduce the potential of hand- and surface-mediated transmission. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  20. A Novel Approach to Highly Damage Tolerant and Abrasion Resistant EVA Gloves, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — As part of the spacesuit pressure garment, the EVA glove incorporates a silicone pad on the palm for protection of the bladder from cuts and punctures. Repeated...

  1. Simulation of the Carton Erection for the Rubber Glove Packing Machine Using Finite Element Method

    Directory of Open Access Journals (Sweden)

    Jewsuwun Kawin

    2017-01-01

    Full Text Available The rubber glove packing machine had been designed an important function which worked with folding carton. Each folded paper carton would be pulled to be erected by vacuum cups. Some carton could not completely form because of an unsuitable design of the erector. Cartons were collapsed or buckling while pulled by vacuum cups that cause to sudden stop the packing process and affect to number and cost of rubber glove production. This research aimed to use simulation method to erect the folded carton. Finite element (FE model of the rubber glove carton was created with shell elements. The orthotropic material properties were employed to specify FE model for analysis erection behavior of the folding carton. Vacuum cups number, positions and rotation points were simulated until obtained a good situation of the folding carton erector. Subsequently, finite element analysis results will be used to fabricate erector of the rubber glove packing machine in a further work.

  2. Study of Bio-Mimicry Surfaces for Optimization of Coupling Performance in Wheelchair Racing Gloves

    Directory of Open Access Journals (Sweden)

    Clara Usma

    2018-03-01

    Full Text Available In wheelchair racing, the optimal pair of gloves, as well as knowledge of conditioning of glove-rim contact surfaces can have a significant impact on race performance. Extreme temperatures, humidity, wet or dry conditions can considerably influence not only the hand-rim friction coupling (effectiveness of the athlete’s push cycle but also the risk of injuries, blisters or sore areas which in turn, can influence the endurance of the athlete across long distance events. This paper reports an experimental study of the effect of bio-mimicry surface textures as a supplement for heightening glove-rim coupling for dry and wet weather conditions. The paper also provides recommendations for the practical implementation of the study findings through a proposal for the design and development of a pair of bespoke gloves for a wheelchair racing athlete for initial prototyping and performance trials.

  3. Pollution prevention benefits of non-hazardous shielding glovebox gloves - 11000

    Energy Technology Data Exchange (ETDEWEB)

    Cournoyer, Michael E [Los Alamos National Laboratory; Dodge, Robert L [Los Alamos National Laboratory

    2011-01-11

    Radiation shielding is commonly used to protect the glovebox worker from unintentional direct and secondary radiation exposure, while working with plutonium-238 and plutonium-239. Shielding glovebox gloves are traditionally composed of lead-based materials, i.e., hazardous waste. This has prompted the development of new, non-hazardous shielding glovebox gloves. No studies, however, have investigated the pollution prevention benefits of these new glovebox gloves. We examined both leaded and non-hazardous shielding glovebox gloves. The nonhazardous substitutes are higher in cost, but this is offset by eliminating the costs associated with onsite waste handling of Resource Conservation and Recovery Act (RCRA) items. In the end, replacing lead with non-hazardous substitutes eliminates waste generation and future liability.

  4. Test of the Fishbein and Ajzen models as predictors of health care workers' glove use.

    Science.gov (United States)

    Levin, P F

    1999-08-01

    The aim of this study was to identify predictors of health care workers' glove use when there is a potential for blood exposure. The study hypothesis was that an extension of the theory of planned behavior would explain more of the variance in glove use behavior than the theory of reasoned action or theory of planned behavior. A random sample of nurses and laboratory workers (N = 527) completed a 26-item questionnaire with acceptable content validity and reliability estimates. Using structural equation modeling techniques, intention, attitude, and perceived risk were significant predictors of behavior. Perceived control and attitude were the significant determinants of intention. The theory of reasoned action was the most parsimonious model, explaining 70% of the variance in glove use behavior. The theory of planned behavior extension was a viable model to study behavior related to glove use and reducing workers' risks to bloodborne diseases.

  5. Protective glove use and hygiene habits modify the associations of specific pesticides with Parkinson’s disease

    Science.gov (United States)

    Furlong, Melissa; Tanner, Caroline M; Goldman, Samuel M; Bhudhikanok, Grace S.; Blair, Aaron; Chade, Anabel; Comyns, Kathleen; Hoppin, Jane A.; Kasten, Meike; Korell, Monica; Langston, J William; Marras, Connie; Meng, Cheryl; Richards, Marie; Ross, G Webster; Umbach, David M; Sandler, Dale P; Kamel, Freya

    2014-01-01

    Pesticides have been associated with Parkinson’s disease (PD), and protective gloves and workplace hygiene can reduce pesticide exposure. We assessed whether use of gloves and workplace hygiene modified associations between pesticides and PD. The Farming and Movement Evaluation (FAME) Study is a nested case-control study within the Agricultural Health Study. Use of protective gloves, other PPE, and hygiene practices were determined by questionnaire (69 cases and 237 controls were included). We considered interactions of gloves and hygiene with ever-use of pesticides for all pesticides with ≥ 5 exposed and unexposed cases and controls in each glove-use stratum (paraquat, permethrin, rotenone, and trifluralin). 61% of respondents consistently used protective gloves and 87% consistently used ≥ 2 hygiene practices. Protective glove use modified the associations of paraquat and permethrin with PD: neither pesticide was associated with PD among protective glove users, while both pesticides were associated with PD among non-users (paraquat OR 3.9 [95% CI 1.3, 11.7], interaction p=0.15; permethrin OR 4.3 [95% CI 1.2, 15.6] interaction p=0.05). Rotenone was associated with PD regardless of glove use. Trifluralin was associated with PD among people who used glove use and hygiene practices appeared to be important modifiers of the association between pesticides and PD and may reduce risk of PD associated with certain pesticides. PMID:25461423

  6. Risk assessment of accidental exposure of surgeons to blood during orthopedic surgery. Are we safe in surgical gloves?

    Directory of Open Access Journals (Sweden)

    Dariusz Timler

    2014-03-01

    Full Text Available Aim. To analyze tears in sterile surgical gloves used by surgeons in the operating theatre of the Trauma and Orthopedic Surgery Department, Copernicus Memorial Hospital, Łódź, Poland Materials and Method. This study analyzes tears in sterile surgical gloves used by surgeons by ICD-9 and ICD-10 codes. 1,404 gloves were collected from 581 surgical procedures. All gloves were tested immediately following surgery using the test method described in Standard EN455–1 (each glove was inflated with 1,000 ± 50 ml of water and observed for leaks for 2–3 min.. Results. Analysis of tears took into consideration the role of medical personnel (operator, first assistant, second assistant during surgical procedure, the type of procedure according to ICD-9 and ICD-10 codes, and the elective or emergency nature of the procedure. The results of the study show that these factors have a significant influence on the risk of glove tears. Significant differences were observed in tear frequency and tear location depending on the function performed by the surgeon during the procedure. Conclusion. The study proved that the role performed by the surgeon during the procedure (operator, first assistant, second assistant has a significant influence on the risk of glove tearing. The role in the procedure determines exposure to glove tears. Implementing a double gloving procedure in surgical procedures or using single gloves characterized by higher tear resistance should be considered.

  7. Norovirus Transmission between Hands, Gloves, Utensils, and Fresh Produce during Simulated Food Handling

    Science.gov (United States)

    Aho, E.; Mikkelä, A.; Ranta, J.; Tuominen, P.; Rättö, M.; Maunula, L.

    2014-01-01

    Human noroviruses (HuNoVs), a leading cause of food-borne gastroenteritis worldwide, are easily transferred via ready-to-eat (RTE) foods, often prepared by infected food handlers. In this study, the transmission of HuNoV and murine norovirus (MuNoV) from virus-contaminated hands to latex gloves during gloving, as well as from virus-contaminated donor surfaces to recipient surfaces after simulated preparation of cucumber sandwiches, was inspected. Virus transfer was investigated by swabbing with polyester swabs, followed by nucleic acid extraction from the swabs with a commercial kit and quantitative reverse transcription-PCR. During gloving, transfer of MuNoV dried on the hand was observed 10/12 times. HuNoV, dried on latex gloves, was disseminated to clean pairs of gloves 10/12 times, whereas HuNoV without drying was disseminated 11/12 times. In the sandwich-preparing simulation, both viruses were transferred repeatedly to the first recipient surface (left hand, cucumber, and knife) during the preparation. Both MuNoV and HuNoV were transferred more efficiently from latex gloves to cucumbers (1.2% ± 0.6% and 1.5% ± 1.9%) than vice versa (0.7% ± 0.5% and 0.5% ± 0.4%). We estimated that transfer of at least one infective HuNoV from contaminated hands to the sandwich prepared was likely to occur if the hands of the food handler contained 3 log10 or more HuNoVs before gloving. Virus-contaminated gloves were estimated to transfer HuNoV to the food servings more efficiently than a single contaminated cucumber during handling. Our results indicate that virus-free food ingredients and good hand hygiene are needed to prevent HuNoV contamination of RTE foods. PMID:24951789

  8. Towards understanding the mechanisms and the kinetics of nanoparticle penetration through protective gloves

    International Nuclear Information System (INIS)

    Vinches, L; Boutrigue, N; Zemzem, M; Hallé, S; Peyrot, C; Lemarchand, L; Wilkinson, K J; Tufenkji, N

    2015-01-01

    Parallel to the increased use of engineered nanoparticles (ENP) in the formulation of commercial products or in medicine, numerous health and safety agencies have recommended the application of the precautionary principle to handle ENP; namely, the recommendation to use protective gloves against chemicals. However, recent studies reveal the penetration of titanium dioxide nanoparticles through nitrile rubber protective gloves in conditions simulating occupational use. This project is designed to understand the links between the penetration of gold nanoparticles (nAu) through nitrile rubber protective gloves and the mechanical and physical behaviour of the elastomer material subjected to conditions simulating occupational use (i.e., mechanical deformations (MD) and sweat). Preliminary analyses show that nAu suspensions penetrate selected glove materials after exposure to prolonged (3 hours) dynamic deformations. Significant morphological changes are observed on the outer surface of the glove sample; namely, the number and the surface of the micropores on the surface increase. Moreover, nitrile rubber protective gloves are also shown to be sensitive to the action of nAu suspension and to the action of the saline solution used to simulate sweat (swelling). (paper)

  9. Organophosphorus pesticide exposure in agriculture: effects of temperature, ultraviolet light and abrasion on PVC gloves

    Science.gov (United States)

    ISMAIL, Ismaniza; GASKIN, Sharyn; PISANIELLO, Dino; EDWARDS, John W.

    2017-01-01

    Elbow length PVC gloves are often recommended for protection against organophosphorus pesticide (OP) exposure in agriculture. However, performance may be reduced due to high temperature, UV exposure and abrasion. We sought to assess these impacts for two OPs under normal use and reasonable worst-case scenarios. Glove permeation tests were conducted using ASTM cells with two PVC glove brands at 23°C and 45°C for up to 8 h. Technical grade dichlorvos and formulated diazinon were used undiluted and at application strength. Breakthough of undiluted dichlorvos occurred at both 23°C and 45°C, but only at 45°C for application strength. Breakthrough of diazinon was not achieved, except when undiluted at 45°C. UV-exposed and abraded gloves showed reduced performance, with the effect being approximately two-fold for dichlorvos. Only small differences were noted between glove brands. Extra precautions should be taken when handling concentrated OPs at high temperature, or when using abraded or sunlight-exposed gloves. PMID:29199264

  10. Are gloves sufficiently protective when hairdressers are exposed to permanent hair dyes? An in vivo study.

    Science.gov (United States)

    Antelmi, Annarita; Young, Ewa; Svedman, Cecilia; Zimerson, Erik; Engfeldt, Malin; Foti, Caterina; Bruze, Magnus

    2015-04-01

    The use of permanent hair dyes exposes hairdressers to contact allergens such as p-phenylenediamine (PPD), and the preventive measures are insufficient. To perform an in vivo test to study the protective effect of gloves commonly used by hairdressers. Six gloves from Sweden, Italy and Germany were studied: two vinyl, one natural rubber latex, two nitrile, and one polyethylene. The hair dye used for the provocation was a dark shade permanent dye containing PPD. The dye was mixed with hydrogen peroxide, and 8 PPD-sensitized volunteers were tested with the gloves as a membrane between the hair dye and the skin in a cylindrical open chamber system. Three exposure times (15, 30 and 60 min) were used. Eczematous reactions were found when natural rubber latex, polyethylene and vinyl gloves were tested with the dye. The nitrile gloves gave good protection, even after 60 min of exposure to the hair dye. Many protective gloves used by hairdressers are unsuitable for protection against the risk of elicitation of allergic contact dermatitis caused by PPD. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Transmission of MRSA to Healthcare Personnel Gowns and Gloves during Care of Nursing Home Residents

    Science.gov (United States)

    Roghmann, Mary-Claire; Johnson, J. Kristie; Sorkin, John D.; Langenberg, Patricia; Lydecker, Alison; Sorace, Brian; Levy, Lauren; Mody, Lona

    2016-01-01

    Objective To estimate the frequency of MRSA transmission to gowns and gloves worn by healthcare personnel (HCP) interacting with nursing home residents in order to inform infection prevention policies in this setting Design Observational study Setting and Participants Residents and HCP from 13 community-based nursing homes in Maryland and Michigan Methods Residents were cultured for MRSA at the anterior nares and perianal or perineal skin. HCP wore gowns and gloves during usual care activities. At the end of each activity, a research coordinator swabbed the HCP’s gown and gloves. Results 403 residents were enrolled; 113 were MRSA colonized. Glove contamination was higher than gown contamination (24% vs. 14% of 954 interactions, pgloves. We identified high risk activities (OR >1.0, pglove contamination. Conclusions MRSA transmission from MRSA positive residents to HCP gown and gloves is substantial with high contact activities of daily living conferring the highest risk. These activities do not involve overt contact with body fluids, skin breakdown or mucous membranes suggesting the need to modify current standards of care involving the use of gowns and gloves in this setting. PMID:26008727

  12. Analysis of Low Speed Stall Aerodynamics of a Swept Wing with Laminar Flow Glove

    Science.gov (United States)

    Bui, Trong T.

    2014-01-01

    Reynolds-Averaged Navier-Stokes (RANS) computational fluid dynamics (CFD) analysis was conducted to study the low-speed stall aerodynamics of a GIII aircraft's swept wing modified with a laminar-flow wing glove. The stall aerodynamics of the gloved wing were analyzed and compared with the unmodified wing for the flight speed of 120 knots and altitude of 2300 ft above mean sea level (MSL). The Star-CCM+ polyhedral unstructured CFD code was first validated for wing stall predictions using the wing-body geometry from the First American Institute of Aeronautics and Astronautics (AIAA) CFD High-Lift Prediction Workshop. It was found that the Star-CCM+ CFD code can produce results that are within the scattering of other CFD codes considered at the workshop. In particular, the Star-CCM+ CFD code was able to predict wing stall for the AIAA wing-body geometry to within 1 degree of angle of attack as compared to benchmark wind-tunnel test data. Current results show that the addition of the laminar-flow wing glove causes the gloved wing to stall much earlier than the unmodified wing. Furthermore, the gloved wing has a different stall characteristic than the clean wing, with no sharp lift drop-off at stall for the gloved wing.

  13. Latex allergy: assessment of knowledge, appropriate use of gloves and prevention practice among hospital healthcare workers.

    Science.gov (United States)

    Al-Niaimi, F; Chiang, Y Z; Chiang, Y N; Williams, J

    2013-01-01

    Healthcare workers and patients are often exposed to natural rubber latex (NRL) through contact with gloves and various healthcare products, which can potentially cause allergic reactions, with varying degrees of severity. In 2008, the Royal College of Physicians published their first evidence-based guidance on occupational health interventions for latex allergy, which emphasized the importance of healthcare workers having knowledge of latex allergy. This study aimed to survey the knowledge of healthcare workers (n = 156) about latex gloves and NRL allergy, routine prevention practice and the appropriate use of gloves in patient care. Healthcare workers in a large teaching hospital were surveyed using a standard questionnaire. We found that only 1% of healthcare workers were able to correctly match the appropriate gloves to the specifically designed procedure. More than half (n = 74.53%) were unable to recognize the presentation of type 1 allergy to NRL. Of the 156 participants, 131 (84%) considered that they would benefit from training about NRL allergy and the use of different types of gloves in clinical care. This survey indicates the importance of education regarding appropriate use of gloves and prevention of NRL allergy among healthcare workers, and dermatologists should play an important role in facilitating this. © The Author(s). CED © 2012 British Association of Dermatologists.

  14. Analysis of Low-Speed Stall Aerodynamics of a Swept Wing with Laminar-Flow Glove

    Science.gov (United States)

    Bui, Trong T.

    2014-01-01

    Reynolds-Averaged Navier-Stokes (RANS) computational fluid dynamics (CFD) analysis was conducted to study the low-speed stall aerodynamics of a GIII aircraft's swept wing modified with a laminar-flow wing glove. The stall aerodynamics of the gloved wing were analyzed and compared with the unmodified wing for the flight speed of 120 knots and altitude of 2300 ft above mean sea level (MSL). The Star-CCM+ polyhedral unstructured CFD code was first validated for wing stall predictions using the wing-body geometry from the First American Institute of Aeronautics and Astronautics (AIAA) CFD High-Lift Prediction Workshop. It was found that the Star-CCM+ CFD code can produce results that are within the scattering of other CFD codes considered at the workshop. In particular, the Star-CCM+ CFD code was able to predict wing stall for the AIAA wing-body geometry to within 1 degree of angle of attack as compared to benchmark wind-tunnel test data. Current results show that the addition of the laminar-flow wing glove causes the gloved wing to stall much earlier than the unmodified wing. Furthermore, the gloved wing has a different stall characteristic than the clean wing, with no sharp lift drop-off at stall for the gloved wing.

  15. Effects of Gloves and Pulling Task on Achievable Downward Pull Forces on a Rung.

    Science.gov (United States)

    Beschorner, Kurt E; Slota, Gregory P; Pliner, Erika M; Spaho, Egli; Seo, Na Jin

    2018-03-01

    Objective We examined the impacts of pulling task (breakaway and pull-down tasks at different postures), glove use, and their interaction on achievable downward pull forces from a ladder rung. Background Posture, glove use, and the type of pulling task are known to affect the achievable forces. However, a gap in the literature exists regarding how these factors affect achievable downward pulling forces, which are relevant to recovery from a perturbation during ladder climbing. Methods Forty subjects completed four downward pulling tasks (breakaway force; pull force at maximum height, shoulder height, and a middle height), using three glove conditions with varying coefficient of friction (COF) levels (cotton glove, low COF; bare hand, moderate COF; and latex-coated glove, high COF) with their dominant and nondominant hand. The outcome variable was the maximum force normalized to body weight. Results The highest forces were observed for the highest hand postures (breakaway and maximum height). Increased COF led to higher forces and had a larger effect on breakaway force than the other tasks. The dominant hand was associated with higher forces than the nondominant hand. Male subjects generated greater forces than female subjects, particularly for higher hand positions. Conclusion This study suggests that a higher hand position on the ladder, while avoiding low-friction gloves, may be effective for improving recovery from ladder perturbations. Application This study may guide preferred climbing strategies (particularly those that lead to a higher hand position) for improving recovery from a perturbation during ladder climbing.

  16. THE INFLUENCE OF FATLIQOURING PROCESS ON PROTECTIVE CHARACTERISTICS OF LEATHER GLOVES

    Directory of Open Access Journals (Sweden)

    KILIÇ Eylem

    2017-05-01

    Full Text Available Appropriate protective gloves are essential for industry workers to avoid hands and wrists injuries. Leather is a common material used by professionals for technical gloves. Mechanical resistance, protection against water and high temperature has to be fulfilled by leather that is intended for using in protective gloves. In this study recipes using various fatliquoring agents with different properties such as lesitin based, lanolin based, polymeric based and water proofing fat liquor were applied to produce technical glove leather and effect of each fatliquoring product on protective performance of leathers were analyzed in terms of physical and mechanical properties including tensile (ISO 3376, stitch tear (ISO 23910, tear resistance (ISO 3377-2, static (ISO 2417 and dynamicwater absorption (ISO 5403-1 and thermal stability such as dry heat (ISO 17227 and heat stability (ISO 11645. For this purpose, chromium tanned split calf leathers were used and retanning of protective leather gloves were performed by using tara and phosphonium combination. Performance testing results obtained from four different retanning processes was compared according to the type of fatliquoring material used in the production. Post-tanning with different types of fatliquoring products have significant effect on the protective performance properties of leather gloves, in terms of mechanical and thermal properties.

  17. First-aid boxes - Reminder

    CERN Multimedia

    GS Department

    2010-01-01

    With a view to ensuring optimum use of the first-aid boxes on the CERN site, we should like to remind you of various changes introduced in March 2009: The TSO of the buildings concerned is responsible for the first-aid boxes, including checking their contents.   First-aid boxes may be restocked ONLY at the CERN stores (SCEM No. 54.99.80). This is no longer possible at the Infirmary. The associated cost is charged to the Departments.   First-aid boxes should be used only for mild injuries. All other cases should be referred to the Medical Service Infirmary (Bldg. 57 – ground-floor, tel. 73802) between 8.00 a.m. and 5.30 p.m. or to the Fire and Rescue Service (tel. 74444). N.B.: This information does not apply to the red emergency first-aid boxes in the underground areas or to the emergency kits for use in the event of being splashed with hydrofluoric acid.

  18. Box graphs and resolutions I

    Directory of Open Access Journals (Sweden)

    Andreas P. Braun

    2016-04-01

    Full Text Available Box graphs succinctly and comprehensively characterize singular fibers of elliptic fibrations in codimension two and three, as well as flop transitions connecting these, in terms of representation theoretic data. We develop a framework that provides a systematic map between a box graph and a crepant algebraic resolution of the singular elliptic fibration, thus allowing an explicit construction of the fibers from a singular Weierstrass or Tate model. The key tool is what we call a fiber face diagram, which shows the relevant information of a (partial toric triangulation and allows the inclusion of more general algebraic blowups. We shown that each such diagram defines a sequence of weighted algebraic blowups, thus providing a realization of the fiber defined by the box graph in terms of an explicit resolution. We show this correspondence explicitly for the case of SU(5 by providing a map between box graphs and fiber faces, and thereby a sequence of algebraic resolutions of the Tate model, which realizes each of the box graphs.

  19. The Short-term Protective Effects of ‘Non-PPE’ Gloves Used by Greenhouse Workers

    Science.gov (United States)

    Roff, Martin

    2015-01-01

    Task-based worker exposure assessments are used in regulatory product approval for pesticides. Some agricultural workers may be exposed to pesticide residues predominantly via transfer to the hands during plant tending or crop harvesting. They may use thin ‘splash-resistant single-use’ (SRSU) gloves or cotton gloves as good industry practice, for example, to protect a delicate crop from bruising, rather than specifically for chemical protection. These ‘non-personal protective equipment (PPE)’ gloves may or may not have been tested for chemical resistance, but can nevertheless give limited protection from chemicals. This paper reports experiments to assess the protection factors (PFs) of ‘non-PPE’ gloves against chemicals, to better inform the regulatory exposure assessments. One type of lightweight cotton and three types of 0.1 mm SRSU gloves 25cm long (latex, nitrile, and vinyl) that might be used as ‘non-PPE’ gloves and one type of 0.4 mm PPE nitrile gauntlet 33cm long were worn by 36 volunteers in greenhouses at four nurseries, handling plants sprayed with transferable but non-permeating strontium acetate in four consecutive 1-h sessions, including one session in which no gloves were worn. Dislodgeable foliar residues were measured by rinsing leaves in bags. Each subject carried out their task such as weeding or trimming, for their four sessions on their set of plants. Handwashes followed each session, and the washings were sampled and analysed for strontium. Unprotected hand contamination was taken to be the within-subject ‘challenge’ in the absence of gloves. It ranged from 166 to 4091 µg equivalent of strontium acetate on the hands and increased with increasing foliar residues. Geometric mean PFs were 60 (95% CI 38–87, n = 22) for PPE gauntlets, 32 (25–41, n = 65) for SRSU gloves and 5.3 (3.5–8, n = 21) for lightweight cotton. The PFs offered by the waterproof gloves (gauntlets and SRSU) increased with challenge, but for the

  20. The Short-term Protective Effects of 'Non-PPE' Gloves Used by Greenhouse Workers.

    Science.gov (United States)

    Roff, Martin

    2015-10-01

    Task-based worker exposure assessments are used in regulatory product approval for pesticides. Some agricultural workers may be exposed to pesticide residues predominantly via transfer to the hands during plant tending or crop harvesting. They may use thin 'splash-resistant single-use' (SRSU) gloves or cotton gloves as good industry practice, for example, to protect a delicate crop from bruising, rather than specifically for chemical protection. These 'non-personal protective equipment (PPE)' gloves may or may not have been tested for chemical resistance, but can nevertheless give limited protection from chemicals. This paper reports experiments to assess the protection factors (PFs) of 'non-PPE' gloves against chemicals, to better inform the regulatory exposure assessments.One type of lightweight cotton and three types of 0.1 mm SRSU gloves 25cm long (latex, nitrile, and vinyl) that might be used as 'non-PPE' gloves and one type of 0.4 mm PPE nitrile gauntlet 33cm long were worn by 36 volunteers in greenhouses at four nurseries, handling plants sprayed with transferable but non-permeating strontium acetate in four consecutive 1-h sessions, including one session in which no gloves were worn. Dislodgeable foliar residues were measured by rinsing leaves in bags. Each subject carried out their task such as weeding or trimming, for their four sessions on their set of plants. Handwashes followed each session, and the washings were sampled and analysed for strontium. Unprotected hand contamination was taken to be the within-subject 'challenge' in the absence of gloves. It ranged from 166 to 4091 µg equivalent of strontium acetate on the hands and increased with increasing foliar residues. Geometric mean PFs were 60 (95% CI 38-87, n = 22) for PPE gauntlets, 32 (25-41, n = 65) for SRSU gloves and 5.3 (3.5-8, n = 21) for lightweight cotton. The PFs offered by the waterproof gloves (gauntlets and SRSU) increased with challenge, but for the absorbent cotton gloves it

  1. Design of the plutonium facility for animal experiments and its management experience

    International Nuclear Information System (INIS)

    Koizumi, Akira; Fukuda, Satoshi

    1998-01-01

    Design and radiation control of authors' facility which was made as a nuclear fuel laboratory for animal experiments were described. Before construction, the animals thought to be used were rats, mice, beagle dogs and monkeys. 239 Pu and certain other radioisotopes were to be used. At present, 200 dogs and 1800 small animals can be maintained. The points for design were tolerability against quake, reduced-pressure management and permanent storage of waste containing Pu. The facility building composed from 2nd, 4th, and 6th laboratory floors and between them, from the so-called mechanical floors which are spaces for ducts. The latter floors are quite useful. The system for reduced pressure is of 3 patterns of rooms without hood, with ordinary hood and with air-curtain hood. For animal maintenance, there are 3 types of maintenance means: Glove box, hood and ordinary animal room. There are drainage equipment where Pu can be removed by precipitation and charcoal adsorption and incineration equipment which is necessary for reducing the waste volume. In the latter, HEPA filters are finally used for releasing the gas. There is no particular problem in the radiation control. For the personnel control, lung-monitoring is performed before and at the end of personnel registration. Environmental monitoring of Pu is optionally performed. Removal of Pu particles generated in the inhalation experiments could be attained by the use of ULPA and HEPA filters to the level less than 1/10 17 times the reference level. Keeping the technology level enough high for facility maintenance and management was considered to be important at present and in future. (K.H.)

  2. Whole glove permeation of cyclohexanol through disposable nitrile gloves on a dextrous robot hand and comparison with the modified closed-loop ASTM F739 method 1. No fist clenching.

    Science.gov (United States)

    Mathews, Airek R; Que Hee, Shane S

    2017-04-01

    The aim was to develop a whole glove permeation method for cyclohexanol to generate permeation parameter data for a non-moving dextrous robot hand (normalized breakthrough time t b , standardized breakthrough time t s , steady state permeation rate P s , and diffusion coefficient D). Four types of disposable powderless, unsupported, and unlined nitrile gloves from the same producer were investigated: Safeskin Blue and Kimtech Science Blue, Purple, and Sterling. The whole glove method developed involved a peristaltic pump for water circulation through chemically resistant Viton tubing to continually wash the inner surface of the test glove via holes in the tubing, a dextrous robot hand operated by a microprocessor, a chemically protective nitrile glove to protect the robot hand, an incubator to maintain 35°C temperature, and a hot plate to maintain 35°C at the sampling point of the circulating water. Aliquots of 1.0 mL were sampled at regular time intervals for the first 60 min followed by removal of 0.5 mL aliquots every hour to 8 hr. Quantification was by the internal standard method after gas chromatography-selective ion electron impact mass spectrometry using a non-polar capillary column. The individual glove values of t b and t s differed for the ASTM closed loop method except for Safeskin Blue, but did not for the whole glove method. Most of the kinetic parameters agreed within an order of magnitude for the two techniques. The order of most protective to least protective glove was Blue and Safeskin, then Purple followed by Sterling for the whole gloves. The analogous order for the modified F739 ASTM closed loop method was: Safeskin, Blue, Purple, and Sterling, almost the same as for the whole glove. The Sterling glove was "not recommended" from the modified ASTM data, and was "poor" from the whole glove data.

  3. Effect of multiple alcohol-based hand rub applications on the tensile properties of thirteen brands of medical exam nitrile and latex gloves.

    Science.gov (United States)

    Gao, Pengfei; Horvatin, Matthew; Niezgoda, George; Weible, Robyn; Shaffer, Ronald

    2016-12-01

    Current CDC guidance for the disinfection of gloved hands during the doffing of personal protective equipment (PPE) following the care of a patient with Ebola recommends for multiple applications of alcohol-based hand rub (ABHR) on medical exam gloves. To evaluate possible effects of ABHR applications on glove integrity, thirteen brands of nitrile and latex medical exam gloves from five manufacturers and two different ABHRs were included in this study. A pair of gloves were worn by a test operator and the outside surfaces of the gloves were separately treated with an ABHR for 1-6 applications. Tensile strength and ultimate elongation of the gloves without any ABHR treatments (control gloves) and gloves after 1-6 ABHR applications were measured based on the ASTM D412 standard method. In general, tensile strength decreased with each ABHR application. ABHRs had more effect on the tensile strength of the tested nitrile than latex gloves, while ethanol-based ABHR (EBHR) resulted in lesser changes in tensile strength compared to isopropanol-based ABHR (IBHR). The results show that multiple EBHR applications on the latex gloves and some of the nitrile gloves tested should be safe for Ebola PPE doffing based on the CDC guidance. Appropriate hospital staff practice using ABHR treatment and doffing gloves is recommended to become more familiar with changes in glove properties.

  4. The effects of arthritis gloves on people with Rheumatoid Arthritis or Inflammatory Arthritis with hand pain: a study protocol for a multi-centre randomised controlled trial (the A-GLOVES trial).

    Science.gov (United States)

    Prior, Yeliz; Sutton, Chris; Cotterill, Sarah; Adams, Jo; Camacho, Elizabeth; Arafin, Nazina; Firth, Jill; O'Neill, Terence; Hough, Yvonne; Jones, Wendy; Hammond, Alison

    2017-05-30

    Arthritis gloves are regularly provided as part of the management of people with rheumatoid arthritis (RA) and undifferentiated (early) inflammatory arthritis (IA). Usually made of nylon and elastane (i.e. Lycra®), these arthritis gloves apply pressure with the aims of relieving hand pain, stiffness and improving hand function. However, a systematic review identified little evidence supporting their use. We therefore designed a trial to compare the effectiveness of the commonest type of arthritis glove provided in the United Kingdom (Isotoner gloves) (intervention) with placebo (control) gloves (i.e. larger arthritis gloves providing similar warmth to the intervention gloves but minimal pressure only) in people with these conditions. Participants aged 18 years and over with RA or IA and persistent hand pain will be recruited from National Health Service Trusts in the United Kingdom. Following consent, participants will complete a questionnaire booklet, then be randomly allocated to receive intervention or placebo arthritis gloves. Within three weeks, they will be fitted with the allocated gloves by clinical specialist rheumatology occupational therapists. Twelve weeks (i.e. the primary endpoint) after completing the baseline questionnaire, participants will complete a second questionnaire, including the same measures plus additional questions to explore adherence, benefits and problems with glove-wear. A sub-sample of participants from each group will be interviewed at the end of their participation to explore their views of the gloves received. The clinical effectiveness and cost-effectiveness of the intervention, compared to placebo gloves, will be evaluated over 12 weeks. The primary outcome measure is hand pain during activity. Qualitative interviews will be thematically analysed. This study will evaluate the commonest type of arthritis glove (Isotoner) provided in the NHS (i.e. the intervention) compared to a placebo glove. The results will help

  5. Specific risk factors and macroeconomic factor on profitability performance an empirical evidence of Top Glove Corporation Bhd

    OpenAIRE

    Loh, Choon Zhee

    2017-01-01

    The purpose of this study to conducted the overall performance of Top Glove Corporation with specific risk factors and macroeconomic factor on profitability performance. The data acquired from annual report of Top Glove Corporation starting from the year of 2011 until 2015. The measurement of liquidity ratio and operating ratio used to see the overall performance of Top Glove in 5 years which allegedly beyond benchmark. The additional measurement is the asset size, this variable has a negativ...

  6. Design and construction of shoulder recesses into the beam aperture shields for improved patient positioning at the FiR 1 BNCT facility

    International Nuclear Information System (INIS)

    Auterinen, I.; Kotiluoto, P.; Hippelaeinen, E.; Kortesniemi, M.; Seppaelae, T.; Seren, T.; Mannila, V.; Poeyry, P.; Kankaanranta, L.; Collan, J.; Kouri, M.; Joensuu, H.; Savolainen, S.

    2004-01-01

    Improvements have been made at the FiR 1 BNCT facility to ease the positioning of the patient with a tumor in the head and neck region into a lateral neutron beam. Shoulder recesses were constructed horizontally on both sides of the beam aperture. When shoulder recesses are not needed, they are filled with neutron attenuating filling blocks. MCNP simulations using an anthropomorphic human model BOMAB phantom showed that the main contribution to the increase in the effective dose to the patient's body due to the shoulder recesses was from the neutron dose of the arm. In a position when one arm is inside the shoulder recess, the maximal effective dose of the patient was estimated to be 0.7 Sv/h. Dose measurements using the twin ionization chamber technique showed that the neutron dose increased on the sides as predicted by the MCNP model but there was no noticeable change in the gamma doses. When making the recesses into the lithium containing neutron shield material tritium contamination was confined using an underpressurized glove box and machine tools with local exhaust. The shoulder recesses give space for more flexible patient positioning and can be considered as a significant improvement of the Finnish BNCT facility

  7. Occupational allergic contact dermatitis caused by sterile non-latex protective gloves: clinical investigation and chemical analyses.

    Science.gov (United States)

    Pontén, Ann; Hamnerius, Nils; Bruze, Magnus; Hansson, Christer; Persson, Christina; Svedman, Cecilia; Thörneby Andersson, Kirsten; Bergendorff, Ola

    2013-02-01

    An increased frequency of occupational contact hand dermatitis among surgical operating theatre personnel has been noticed. To evaluate patients with occupational contact dermatitis caused by their rubber gloves, and to describe a method for analysing the content of the allergens in the gloves. Patch tests were performed with the baseline series, a rubber chemical series, and the patients' own gloves. A method for analysing 1,3-diphenylguanidine (DPG) and cetylpyridinium chloride in the gloves was developed. Contact allergy to thiuram mix was found in 8 of 16 patients, whereas 12 of 16 patients reacted to DPG. In 7 of 8 patients, contact allergy to cetylpyridinium chloride was found. In the patients' gloves, cetylpyridinium chloride and DPG were detected at higher concentrations on the inside of the gloves than on the outside. Most patients had worked for decades in their present occupations, but their hand dermatitis had only been present for months. Contact allergy to DPG in gloves has been disputed, but, in this study, we were able to confirm the presence of DPG and cetylpyridinium chloride in the causative gloves by using a modified method for the analysis. The presence of these chemicals in gloves caused an increase in occupational contact dermatitis in surgical operating theatre personnel. © 2012 John Wiley & Sons A/S.

  8. Penetration of protective gloves as a route of intake for tritiated water and 125I-labelled sodium iodine solution

    International Nuclear Information System (INIS)

    Harris, S.J.; Gilmore, A.

    1980-01-01

    Measurements have been made of the rate at which tritiated water and 125 I-labelled sodium iodide solution penetrate various types of protective gloves, both isotopes being in common use in this form in universities and similar establishments. Diffusion coefficients relating to the glove materials are also determined. The health physics aspects are discussed and it is concluded that intakes by workers through intact gloves are not likely to be of major significance and can easily be minimised by the correct use and choice of glove. (author)

  9. Factors influencing the end of the service life of protective gloves used in car repair shops: a preliminary report.

    Science.gov (United States)

    Emilia, Irzmańska; Agnieszka, Stefko; Katarzyna, Dyńska-Kukulska

    2015-01-01

    The paper presents the results of an end-of-service-life study on 2 kinds of protective gloves designed for workplaces in which workers are exposed to mineral oils and mechanical factors. The authors developed their own end-of-service-life study method that takes into account factors occurring during real-life use of protective gloves. The examined gloves were subjected to mechanical, chemical, and physical factors. The objective of the study was to compare the protective in new gloves subjected to a laboratory simulation test and in gloves used at workplaces in car repair shops. A further goal was to design a glove assessment procedure that would ensure comprehensive analysis of the actual level of performance provided by gloves exposed to selected chemical and mechanical factors as well as subjected to the influence of temperature and humidity, mechanical damage, and chemical degradation of material. The results lead to the conclusion that simultaneous exposure of protective gloves to mechanical, chemical, and physical factors significantly decreases their performance levels. Furthermore, similar performance levels were obtained for gloves subjected to laboratory simulation tests and for those used in the workplace.

  10. An Improvised "Blow Glove" Device Produces Similar PEP Values to a Commercial PEP Device: An Experimental Study.

    Science.gov (United States)

    Dagan, Yaakov; Wiser, Itay; Weissman, Oren; Farber, Nimrod; Hundeshagen, Gabriel; Winkler, Eyal; Kazula-Halabi, Tamar; Haik, Josef

    2014-01-01

    Postoperative positive expiratory pressure (PEP) therapy promotes increased lung volume, secretion clearance, and improved oxygenation. Several commercial devices exist that produce recommended PEP values (10-20 cmH2O) when the patient breathes through a fixed orifice resistor. It was hypothesized that an inexpensive, improvised "blow glove" device would produce similar PEP values over a wider range of expiration volumes and flow rates. PEP for different expiration volumes (400-2000 mL) and expiratory flow rates (10-80 L/min) was compared between a commercial PEP device (Resistex, Mercury Medical, Clearwater, FL) and an improvised "blow glove" device, recorded by a Vela ventilator (CareFusion, San Diego, CA). Dynamics in positive end expiratory pressure (PEEP) values were evaluated following five consecutive expirations. The "blow glove" device was evaluated using various glove compositions and sizes. The improvised "blow glove" device produced a significantly higher rate of PEP values in the recommended range than the Resistex device (88.9% vs. 20%, p0.05), but the powdered latex glove showed a significantly higher rate of PEP values in the recommended range than the powder-free latex glove (88.9% vs. 44.4%, pblow glove" PEP device using a powdered latex glove produces PEP values in the recommended range over a wider spectrum of expiratory flow rates and expiration volumes than a commercial PEP device.

  11. Use of Protective Gloves in Nail Salons in Manhattan, New York City

    Directory of Open Access Journals (Sweden)

    Corey Basch

    2016-07-01

    Full Text Available Objectives: Nail salon owners in New York City (NYC are required to provide their workers with gloves and it is their responsibility to maintain healthy, safe working spaces for their employees. The purpose of this study was to determine the frequency with which nail salon workers wear protective gloves. Methods: A Freedom of Information Law request was submitted to New York Department of State’s Division of Licensing Services for a full list of nail salons in Manhattan, NYC. A sample population of 800 nail salons was identified and a simple random sample (without replacement of 30% (n=240 was selected using a random number generator. Researchers visited each nail salon from October to December of 2015, posing as a potential customer to determine if nail salon workers were wearing gloves. Results: Among the 169 salons in which one or more workers was observed providing services, a total of 562 workers were observed. For 149 salons, in which one or more worker was observed providing services, none of the workers were wearing gloves. In contrast, in six of the salons observed, in which one or more workers was providing services, all of the workers (1 in 2 sites, 2 in 1 site, 3 in 2 sites, and 4 in 1 site were wearing gloves. Almost three-quarters of the total number of workers observed (n=415, 73.8% were not wearing gloves. Conclusions: The findings of this study indicate that, despite recent media attention and legislation, the majority of nail salon workers we observed were not wearing protective gloves when providing services.

  12. Use of Protective Gloves in Nail Salons in Manhattan, New York City.

    Science.gov (United States)

    Basch, Corey; Yarborough, Christina; Trusty, Stephanie; Basch, Charles

    2016-07-01

    Nail salon owners in New York City (NYC) are required to provide their workers with gloves and it is their responsibility to maintain healthy, safe working spaces for their employees. The purpose of this study was to determine the frequency with which nail salon workers wear protective gloves. A Freedom of Information Law request was submitted to New York Department of State's Division of Licensing Services for a full list of nail salons in Manhattan, NYC. A sample population of 800 nail salons was identified and a simple random sample (without replacement) of 30% (n=240) was selected using a random number generator. Researchers visited each nail salon from October to December of 2015, posing as a potential customer to determine if nail salon workers were wearing gloves. Among the 169 salons in which one or more workers was observed providing services, a total of 562 workers were observed. For 149 salons, in which one or more worker was observed providing services, none of the workers were wearing gloves. In contrast, in six of the salons observed, in which one or more workers was providing services, all of the workers (1 in 2 sites, 2 in 1 site, 3 in 2 sites, and 4 in 1 site) were wearing gloves. Almost three-quarters of the total number of workers observed (n=415, 73.8%) were not wearing gloves. The findings of this study indicate that, despite recent media attention and legislation, the majority of nail salon workers we observed were not wearing protective gloves when providing services.

  13. Impact of universal gowning and gloving on health care worker clothing contamination.

    Science.gov (United States)

    Williams, Calvin; McGraw, Patty; Schneck, Elyse E; LaFae, Anna; Jacob, Jesse T; Moreno, Daniela; Reyes, Katherine; Cubillos, G Fernando; Kett, Daniel H; Estrella, Ronald; Morgan, Daniel J; Harris, Anthony D; Drees, Marci

    2015-04-01

    To determine whether gowning and gloving for all patient care reduces contamination of healthcare worker (HCW) clothing, compared to usual practice. Cross-sectional surveys. Five study sites were recruited from intensive care units (ICUs) randomized to the intervention arm of the Benefits of Universal Gown and Glove (BUGG) study. All HCWs performing direct patient care in the study ICUs were eligible to participate. Surveys were performed first during the BUGG intervention study period (July-September 2012) with universal gowning/gloving and again after BUGG study conclusion (October-December 2012), with resumption of usual care. During each phase, HCW clothing was sampled at the beginning and near the end of each shift. Cultures were performed using broth enrichment followed by selective media. Acquisition was defined as having a negative clothing culture for samples taken at the beginning of a shift and positive clothing culture at for samples taken at the end of the shift. A total of 348 HCWs participated (21-92 per site), including 179 (51%) during the universal gowning/gloving phase. Overall, 51 (15%) HCWs acquired commonly pathogenic bacteria on their clothing: 13 (7.1%) HCWs acquired bacteria during universal gowning/gloving, and 38 (23%) HCWs acquired bacteria during usual care (odds ratio [OR], 0.3; 95% confidence interval [CI], 0.2-0.6). Pathogens identified included S. aureus (25 species, including 7 methicillin-resistant S. aureus [MRSA]), Enterococcus spp. (25, including 1 vancomycin-resistant Enterococcus [VRE]), Pseudomonas spp. (4), Acinetobacter spp. (4), and Klebsiella (2). Nearly 25% of HCWs practicing usual care (gowning and gloving only for patients with known resistant bacteria) contaminate their clothing during their shift. This contamination was reduced by 70% by gowning and gloving for all patient interactions.

  14. Effect of dental tool surface texture and material on static friction with a wet gloved fingertip.

    Science.gov (United States)

    Laroche, Charles; Barr, Alan; Dong, Hui; Rempel, David

    2007-01-01

    Hand injuries are an important cause of pain and disability among dentists and dental hygienists and may be due to the high pinch forces involved in periodontal work. The pinch forces required to perform scaling may be reduced by increasing the friction between the tool and fingers. The purpose of this study was to determine whether modifying the tool material, surface texture, or glove type altered the coefficient of static friction for a wet gloved finger. Seven tools with varying surface topography were machined from 13 mm diameter stainless steel and Delrin and mounted to a 6-component force plate. The textures tested were a fine, medium and coarse diamond knurled pattern and a medium and fine annular pattern (concentric rings). Thirteen subjects pulled their gloved, wet thumb pad along the long axis of the tool while maintaining a normal force of 40 N. Latex and nitrile gloves were tested. The coefficient of static friction was calculated from the shear force history. The mean coefficients of static friction ranged from 0.20 to 0.65. The coefficient of static friction was higher for a smooth tool of Delrin than one of stainless steel. Differences in the coefficient of static friction were observed between the coarse and medium knurled patterns and the fine knurled and annular patterns. Coefficients of static friction were higher for the nitrile glove than the latex glove for tools with texture. These findings may be applied to the design of hand tools that require fine motor control with a wet, gloved hand.

  15. The Bird Box Survey Project

    Science.gov (United States)

    Willis, Patrick

    2014-01-01

    When high school students are asked what's the best part of science class, many will say it's the field trips. Students enjoy engaging in authentic, community-based science outside the classroom. To capitalize on this, Patrick Willis created the Bird Box Survey Project for his introductory field biology class. The project takes students…

  16. On the Dirichlet's Box Principle

    Science.gov (United States)

    Poon, Kin-Keung; Shiu, Wai-Chee

    2008-01-01

    In this note, we will focus on several applications on the Dirichlet's box principle in Discrete Mathematics lesson and number theory lesson. In addition, the main result is an innovative game on a triangular board developed by the authors. The game has been used in teaching and learning mathematics in Discrete Mathematics and some high schools in…

  17. Design and test of box girder for a large wind turbine blade

    DEFF Research Database (Denmark)

    Nielsen, Per Hørlyk; Tesauro, Angelo; Bitsche, Robert

    , which create an inner structure in the box girder. With a combination of advanced FEM analysis and the inventions it was possible to reduce the material thickness of the cap by up to 40%. The new design of the box girder was manufactured at SSP Technology A/S, where it was demonstrated......This report is covering the structural design and full scale test of a box girder as a part of the project “Demonstration of new blade design using manufacturing process simulations” supported by the EUDP program. A box girder with a predetermined outer geometry was designed using new inventions...... that the manufacturing process could include the new inventions. Subsequently the box girder was transported to the blade test facility at DTU Wind Energy. A series of test was performed with the blade to investigate the behaviour during loading, and finally the girder was loaded to ultimate failure. The report includes...

  18. Evaluation of bike boxes at signalized intersections.

    Science.gov (United States)

    Dill, Jennifer; Monsere, Christopher M; McNeil, Nathan

    2012-01-01

    This paper presents a before-after study of bike boxes at 10 signalized intersections in Portland, Oregon. The bike boxes, also known as advanced stop lines or advanced stop boxes, were installed to increase visibility of cyclists and reduce conflicts between motor vehicles and cyclists, particularly in potential "right-hook" situations. Before and after video were analyzed for seven intersections with green bike boxes, three intersections with uncolored bike boxes, and two control intersections. User perceptions were measured through surveys of cyclists passing through five of the bike box intersections and of motorists working downtown, where the boxes were concentrated. Both the observations and survey of motorists found a high rate of compliance and understanding of the markings. Overall, 73% of the stopping motor vehicles did not encroach at all into the bike box. Both motor vehicle and bicycle encroachment in the pedestrian crosswalk fell significantly at the bike box locations compared to the control intersections. The bike boxes had mixed effects on the motorists' encroachment in the bicycle lane. The number of observed conflicts at the bike box locations decreased, while the total number of cyclists and motor vehicles turning right increased. Negative-binomial models based upon the data predict fewer conflicts with the boxes, particularly as right-turning motor vehicle volumes increase. Observations of yielding behavior at two bike box and one control intersection found an improvement in motorists yielding to cyclists at the bike box locations. Differences in the traffic volumes and location contexts make firm conclusions about the effects of green coloring of the boxes difficult. Higher shares of surveyed motorists felt that the bike boxes made driving safer rather than more dangerous, even when the sample was narrowed to respondents who were not also cyclists. Over three-quarters of the surveyed cyclists thought that the boxes made the intersection safer

  19. Effects of glovebox gloves on grip and key pinch strength and contact forces for simulated manual operations with three commonly used hand tools.

    Science.gov (United States)

    Sung, Peng-Cheng

    2014-01-01

    This study examined the effects of glovebox gloves for 11 females on maximum grip and key pinch strength and on contact forces generated from simulated tasks of a roller, a pair of tweezers and a crescent wrench. The independent variables were gloves fabricated of butyl, CSM/hypalon and neoprene materials; two glove thicknesses; and layers of gloves worn including single, double and triple gloving. CSM/hypalon and butyl gloves produced greater grip strength than the neoprene gloves. CSM/hypalon gloves also lowered contact forces for roller and wrench tasks. Single gloving and thin gloves improved hand strength performances. However, triple layers lowered contact forces for all tasks. Based on the evaluating results, selection and design recommendations of gloves for three hand tools were provided to minimise the effects on hand strength and optimise protection of the palmar hand in glovebox environments. To improve safety and health in the glovebox environments where gloves usage is a necessity, this study provides recommendations for selection and design of glovebox gloves for three hand tools including a roller, a pair of tweezers and a crescent wrench based on the results discovered in the experiments.

  20. Inactivation of Escherichia coli O157:H7 and Salmonella during washing of contaminated gloves in levulinic acid and sodium dodecyl sulfate solutions.

    Science.gov (United States)

    Erickson, Marilyn C; Liao, Jye-Yin; Habteselassie, Mussie Y; Cannon, Jennifer L

    2018-08-01

    Field workers often wear gloves harvesting ready-to-eat produce; however, fields are not sterile environments and gloves may become contaminated numerous times during a working shift. This study explored the potential for inactivation of Escherichia coli O157:H7 and Salmonella when contaminated gloves were washed in levulinic acid (LV) and sodium dodecyl sulfate (SDS) solutions. Washing nitrile gloves with increasing concentrations of LV above 1.0% led to a decreased prevalence of glove contamination by Salmonella (P = 0.0000). A higher level of prevalence occurred for solid agar-cultured pathogens than liquid broth-cultured pathogens after nitrile gloves were washed in LV/SDS (P = 0.0000). Pathogens residing on latex gloves were more likely to be completely inactivated by washing in 0.5% LV/0.1% SDS solutions than nitrile or Canners gloves that exhibited inconsistent responses dependent on the pathogen strain. However, drying after washing nitrile gloves in 0.5% LV/0.1% SDS led to additional pathogen inactivation (P = 0.0394). Pathogen transfer from gloves to produce was implied as the pathogen prevalence on cantaloupe rind handled by LV/SDS-washed gloves was not statistically different from the prevalence on gloves (P = 0.7141). Hence, the risk of produce contamination may still exist but would be reduced by washing gloves in LV/SDS. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Development and Implementation of a Segment/Junction Box Level Database for the ITS Fiber Optic Conduit Network

    Science.gov (United States)

    2012-03-01

    This project initiated the development of a computerized database of ITS facilities, including conduits, junction : boxes, cameras, connections, etc. The current system consists of a database of conduit sections of various lengths. : Over the length ...

  2. The effects of weight levels and gloves on the ability to discriminate weight difference.

    Science.gov (United States)

    Shih, Y C; Wang, M J

    1996-05-01

    In this study, six different types of gloves commonly used in industry (surgical, cotton, nylon, leather, rubber, and whizard knife hand gloves) were evaluated at four different weight levels (8.2, 3, 1.5 and 0.25 kg). Six males and six females voluntarily took part in this study. The dependent variable was the difference limen (or difference threshold) (abbreviated as DL(%)) of the discriminating weight difference (DWD). A nested-factorial design with the subject nested under gender was employed. The results indicate that the weight level had a negatively significant effect on the DL(%). The mean difference thresholds were 3.49, 5.39, 6.08, and 9.45 for the weight levels at 8.2, 3, 1.5, and 0.25 kg, respectively. The individual difference becomes obvious when the weight level is relatively light (0.25 kg). However, the effects of gender, glove, gender x weight, and weight x glove were found to be insignificant, and there was no significant correlation between the DL(%) and glove characteristics (thickness and weight). Subsequently, four additional weight levels (0.01, 0.5, 1 and 15 kg) were considered, and a psychophysical equation was derived: DL(%) = 34.33 x W(0.238) (R2 = 0.98), where W represents the weight level. These results support the power function. A minimum weight difference with 90% confidence of correct detection was suggested.

  3. A quantification of occupational skin exposures and the use of protective gloves among hairdressers in Denmark.

    Science.gov (United States)

    Lysdal, Susan Hovmand; Johansen, Jeanne Duus; Flyvholm, Mari-Ann; Søsted, Heidi

    2012-06-01

    Occupational hand eczema is common in hairdressers, owing to excessive exposure to wet work and hairdressing chemicals. To quantify occupational skin exposure and the use of protective gloves among hairdressers in Denmark. A register-based study was conducted comprising all graduates from hairdressing vocational schools from 1985 to 2007 (n = 7840). The participants received a self-administered postal questionnaire in May 2009, including questions on hairdressing tasks performed in the past week at work and the extent of glove use. A response rate of 67.9% (n = 5324) was obtained. Of the respondents, 55.7% still worked as hairdressers, and they formed the basis of this study. Daily wet work was excessive; 86.6% had wet hands for ≥2 hr, and 54% for ≥ 4 hr. Glove use was fairly frequent for full head hair colouring and bleaching procedures (93-97.7%), but less frequent for highlighting/lowlighting procedures (49.7-60.5%) and permanent waving (28.3%). Gloves were rarely worn during hair washing (10%), although this was more frequently the case after hair colouring procedures (48.9%). Occupational skin exposure was excessive among hairdressers; the extent of wet work and chemical treatments was high, and glove use was inconsistent, especially for certain hair colouring procedures and wet work tasks. © 2012 John Wiley & Sons A/S.

  4. Permeation of limonene through disposable nitrile gloves using a dextrous robot hand

    Science.gov (United States)

    Banaee, Sean; S Que Hee, Shane

    2017-01-01

    Objectives: The purpose of this study was to investigate the permeation of the low-volatile solvent limonene through different disposable, unlined, unsupported, nitrile exam whole gloves (blue, purple, sterling, and lavender, from Kimberly-Clark). Methods: This study utilized a moving and static dextrous robot hand as part of a novel dynamic permeation system that allowed sampling at specific times. Quantitation of limonene in samples was based on capillary gas chromatography-mass spectrometry and the internal standard method (4-bromophenol). Results: The average post-permeation thicknesses (before reconditioning) for all gloves for both the moving and static hand were more than 10% of the pre-permeation ones (P≤0.05), although this was not so on reconditioning. The standardized breakthrough times and steady-state permeation periods were similar for the blue, purple, and sterling gloves. Both methods had similar sensitivity. The lavender glove showed a higher permeation rate (0.490±0.031 μg/cm2/min) for the moving robotic hand compared to the non-moving hand (P≤0.05), this being ascribed to a thickness threshold. Conclusions: Permeation parameters for the static and dynamic robot hand models indicate that both methods have similar sensitivity in detecting the analyte during permeation and the blue, purple, and sterling gloves behave similarly during the permeation process whether moving or non-moving. PMID:28111415

  5. Penelitian jumlah penggunaan bating agent pada penyamakan kulit sarung tangan (fashion glove dari kulit kelinci

    Directory of Open Access Journals (Sweden)

    Muchtar Lutfi

    1994-04-01

    Full Text Available The objective of this research is to identify the quatity of bating agent used in tanning rabbit skins to be glove leather, to make use rabbit skins which can not be tanned to fur rabbit skin leather. The materials used in this research were of 40 pieces of lokal salt preservated rabbit skins originated from Yogyakarta having quality III and IV. They were grouped into four and the groups consisted of ten pieces each were tanned to be fashion glove leather using 4% formaline as pretanning agent and followed by chrome tanning agent as the retanning agent. Before carrying out both tanning processes bating was done on them using Pancreol Bate as bating agent. The quantity of bating agent added was varried as 0,65%, 1,2%, 1,8% and 2,4%. The process used was of usually carried - out by IRDLAI. The leather produced were tested on their sotfness, with sheepskin glove leather was used as the measuring- rod; their tensile strength resistance and flexibility with SII. 0061 – 74 (Quality and test method for goatsheep skin glove and garment leather as the standard of comparison. The test results were statistically evaluated. A conclusion can be down from this research that by using 0,6% Pancreol Bate on bating process, soft glove leathers having good tensile strength and flexibility which fulfill the requirements of SII. 0061 - 74 can be produced.

  6. Perforation of dental gloves during prosthodontic treatments as assessed by the conductivity and water inflation tests.

    Science.gov (United States)

    Nikawa, H; Hamada, T; Tamamoto, M; Abekura, H; Murata, H

    1996-01-01

    The incidence of latex glove perforation during prosthodontic treatment was investigated on 122 occasions using two methods, a conductivity test and a water inflation test. Latex glove perforation was detected in 38.5% of the treatments by the conductivity test and in 27.9% by the water inflation test. The perforation went unrecognized in 74.7% of the occurrences (35/47 incidents) using the conductivity test and in 64.7% (22/34) when the water inflation test was used. Of the total 55 glove perforations, 21 perforations were detected only by conductivity test, 3 were detected only by the water inflation test, and 31 perforations were detected by both methods, which suggested that the conductivity test is more sensitive than the water inflation test for the detection of glove perforation. The results of this research suggested that even when latex gloves are worn, the risk to prosthodontists of exposure to body fluids remains in four of every six treatments, often without the awareness of the prosthodontist.

  7. The Effects of Industrial Protective Gloves and Hand Skin Temperatures on Hand Grip Strength and Discomfort Rating.

    Science.gov (United States)

    Ramadan, Mohamed Z

    2017-12-04

    Daily working activities and functions require a high contribution of hand and forearm muscles in executing grip force. To study the effects of wearing different gloves on grip strength, under a variety of hand skin temperatures, an assessment of the maximum grip strength was performed with 32 healthy male workers with a mean age (standard deviation) of 30.44 (5.35) years wearing five industrial gloves at three hand skin temperatures. Their ages and anthropometric characteristics including body mass index (BMI), hand length, hand width, hand depth, hand palm, and wrist circumference were measured. The hand was exposed to different bath temperatures (5 °C, 25 °C, and 45 °C) and hand grip strength was measured using a Jamar hydraulic hand dynamometer with and without wearing the gloves (chemical protection glove, rubber insulating glove, anti-vibration impact glove, cotton yarn knitted glove, and RY-WG002 working glove). The data were analyzed using the Shapiro-Wilk test, Pearson correlation coefficient, Tukey test, and analysis of variance (ANOVA) of the within-subject design analysis. The results showed that wearing gloves significantly affected the maximum grip strength. Wearing the RY-WG002 working glove produced a greater reduction on the maximum grip when compared with the bare hand, while low temperatures (5 °C) had a significant influence on grip when compared to medium (25 °C) and high (45 °C) hand skin temperatures. In addition, participants felt more discomfort in both environmental extreme conditions. Furthermore, they reported more discomfort while wearing neoprene, rubber, and RY-WG002 working gloves.

  8. The Heuristic Interpretation of Box Plots

    Science.gov (United States)

    Lem, Stephanie; Onghena, Patrick; Verschaffel, Lieven; Van Dooren, Wim

    2013-01-01

    Box plots are frequently used, but are often misinterpreted by students. Especially the area of the box in box plots is often misinterpreted as representing number or proportion of observations, while it actually represents their density. In a first study, reaction time evidence was used to test whether heuristic reasoning underlies this…

  9. Water box for steam generator

    International Nuclear Information System (INIS)

    Lecomte, Robert; Viaud, Michel.

    1975-01-01

    This invention relates to a water box for connecting an assembly composed of a vertical steam generator and a vertical pump to the vessel of the nuclear reactor, the assembly forming the primary cooling system of a pressurised water reactor. This invention makes it easy to dismantle the pump on the water box without significant loss of water in the primary cooling system of the reactor and particularly without it being necessary to drain the water contained in the steam generator beforehand. It makes it possible to shorten the time required for dismantling the primary pump in order to service or repair it and makes dismantling safer in that the dismantling does not involve draining the steam generator and therefore the critical storage of a large amount of cooling water that has been in contact with the fuel assemblies of the nuclear reactor core [fr

  10. Autoantibodies to box A of high mobility group box 1 in systemic lupus erythematosus

    NARCIS (Netherlands)

    Schaper, F.; de Leeuw, K.; Horst, G.; Maas, F.; Bootsma, H.; Heeringa, P.; Limburg, P. C.; Westra, J.

    Autoantibodies to nuclear structures are a hallmark of systemic lupus erythematosus (SLE), including autoantibodies to nuclear protein high mobility group box 1 (HMGB1). HMGB1 consists of three separate domains: box A, box B and an acidic tail. Recombinant box A acts as a competitive antagonist for

  11. Autoantibodies to box A of high mobility group box 1 in systemic lupus erythematosus

    NARCIS (Netherlands)

    Schaper, F.; Leeuw, K. de; Horst, G. ter; Maas, F.; Bootsma, H.; Heeringa, P.; Limburg, P.C.; Westra, J.

    2017-01-01

    Autoantibodies to nuclear structures are a hallmark of systemic lupus erythematosus (SLE), including autoantibodies to nuclear protein high mobility group box 1 (HMGB1). HMGB1 consists of three separate domains: box A, box B and an acidic tail. Recombinant box A acts as a competitive antagonist for

  12. Box-shaped halophilic bacteria.

    OpenAIRE

    Javor, B; Requadt, C; Stoeckenius, W

    1982-01-01

    Three morphologically similar strains of halophilic, box-shaped procaryotes have been isolated from brines collected in the Sinai, Baja California (Mexico), and southern California (United States). Although the isolates in their morphology resemble Walsby's square bacteria, which are a dominant morphological type in the Red Sea and Baja California brines, they are probably not identical to them. The cells show the general characteristics of extreme halophiles and archaebacteria. They contain ...

  13. Gloves against mineral oils and mechanical hazards: composites of carboxylated acrylonitrile-butadiene rubber latex.

    Science.gov (United States)

    Krzemińska, Sylwia; Rzymski, Władysław M; Malesa, Monika; Borkowska, Urszula; Oleksy, Mariusz

    2016-09-01

    Resistance to permeation of noxious chemical substances should be accompanied by resistance to mechanical factors because the glove material may be torn, cut or punctured in the workplace. This study reports on glove materials, protecting against mineral oils and mechanical hazards, made of carboxylated acrylonitrile-butadiene rubber (XNBR) latex. The obtained materials were characterized by a very high resistance of the produced materials to oil permeation (breakthrough time > 480 min). The mechanical properties, and especially tear resistance, of the studied materials were improved after the addition of modified bentonite (nanofiller) to the XNBR latex mixture. The nanocomposite meets the requirements in terms of parameters characterizing tear, abrasion, cut and puncture resistance. Therefore, the developed material may be used for the production of multifunctional protective gloves.

  14. Gloves against mineral oils and mechanical hazards: composites of carboxylated acrylonitrile–butadiene rubber latex

    Science.gov (United States)

    Krzemińska, Sylwia; Rzymski, Władysław M.; Malesa, Monika; Borkowska, Urszula; Oleksy, Mariusz

    2016-01-01

    Resistance to permeation of noxious chemical substances should be accompanied by resistance to mechanical factors because the glove material may be torn, cut or punctured in the workplace. This study reports on glove materials, protecting against mineral oils and mechanical hazards, made of carboxylated acrylonitrile–butadiene rubber (XNBR) latex. The obtained materials were characterized by a very high resistance of the produced materials to oil permeation (breakthrough time > 480 min). The mechanical properties, and especially tear resistance, of the studied materials were improved after the addition of modified bentonite (nanofiller) to the XNBR latex mixture. The nanocomposite meets the requirements in terms of parameters characterizing tear, abrasion, cut and puncture resistance. Therefore, the developed material may be used for the production of multifunctional protective gloves. PMID:26757889

  15. Latex glove sensitivity amongst diagnostic imaging healthcare personnel: a self-reporting investigation

    International Nuclear Information System (INIS)

    Healy, Jan; Brennan, Patrick C.; Bowden, Julie Anne

    2003-01-01

    The use of latex gloves has risen dramatically among healthcare workers resulting in an increase in the number of workers experiencing reactions to gloves. Little evidence of reactions among Irish healthcare workers is available. The current, self-reporting study investigated the prevalence to latex gloves amongst four professional groups within three Diagnostic Imaging Departments. Prevalence is similar to that demonstrated elsewhere with 18.3% of individuals expressing latex associated symptoms. Symptoms included itching and redness of hands, dry cracked skin, soreness of eyes and upper respiratory tract complaints. These results indicate that latex hypersensitivity is a real problem amongst Irish healthcare workers. This preliminary work provides the basis of a much larger controlled study currently being planned

  16. A quantification of occupational skin exposures and the use of protective gloves among hairdressers in Denmark

    DEFF Research Database (Denmark)

    Lysdal, Susan Hovmand; Johansen, Jeanne Duus; Flyvholm, Mari-Ann

    2012-01-01

    Background. Occupational hand eczema is common in hairdressers, owing to excessive exposure to wet work and hairdressing chemicals. Objectives. To quantify occupational skin exposure and the use of protective gloves among hairdressers in Denmark. Methods. A register-based study was conducted...... comprising all graduates from hairdressing vocational schools from 1985 to 2007 (n = 7840). The participants received a self-administered postal questionnaire in May 2009, including questions on hairdressing tasks performed in the past week at work and the extent of glove use. A response rate of 67.9% (n...... = 5324) was obtained. Results. Of the respondents, 55.7% still worked as hairdressers, and they formed the basis of this study. Daily wet work was excessive; 86.6% had wet hands for =2 hr, and 54% for = 4 hr. Glove use was fairly frequent for full head hair colouring and bleaching procedures (93...

  17. ALTERATIONS IN ELECTROCARDIOGRAMS OF LABRADOR RETRIEVER DOGS DURING HANDLING WITH AND WITHOUT GLOVES

    Directory of Open Access Journals (Sweden)

    Swagat Mohapatra

    2016-12-01

    Full Text Available Healthy male Labrador Retriever dogs (n=8 aged between one to three years constituted the study material. The study was carried out to peruse the alterations in electrocardiograms, when the attendant restrained the dogs with bare hands and when the dogs were restrained by the attendant wearing gloves. The mean amplitude of P wave was higher in dogs handled with gloves. Similarly, the amplitudes of QRS complex and T wave were higher in the electrocardiograms of dogs handled with insulated hands. Meanwhile, the duration of T wave and Q-T interval were higher in the electrocardiograms recorded without gloves in hands. However, no alterations were perceived with respect to the duration of P wave, duration of T wave, the P-R interval, R-R interval and the heart rate. Except for the amplitude of P wave, no other differences were statistically significant. The study reported the alterations in the electrocardiogram while handling the animals with bare hands.

  18. The Birmingham Irradiation Facility

    International Nuclear Information System (INIS)

    Dervan, P.; French, R.; Hodgson, P.; Marin-Reyes, H.; Wilson, J.

    2013-01-01

    At the end of 2012 the proton irradiation facility at the CERN PS will shut down for two years. With this in mind, we have been developing a new ATLAS scanning facility at the University of Birmingham Medical Physics cyclotron. With proton beams of energy approximately 30 MeV, fluences corresponding to those of the upgraded Large Hadron Collider (HL-LHC) can be reached conveniently. The facility can be used to irradiate silicon sensors, optical components and mechanical structures (e.g. carbon fibre sandwiches) for the LHC upgrade programme. Irradiations of silicon sensors can be carried out in a temperature controlled cold box that can be scanned through the beam. The facility is described in detail along with the first tests carried out with mini (1×1 cm 2 ) silicon sensors

  19. The Birmingham Irradiation Facility

    Energy Technology Data Exchange (ETDEWEB)

    Dervan, P. [The University of Liverpool, Department of Physics (United Kingdom); French, R.; Hodgson, P. [The University of Sheffield, Department of Physics and Astronomy (United Kingdom); Marin-Reyes, H., E-mail: h.marin-reyes@sheffield.ac.uk [The University of Sheffield, Department of Physics and Astronomy (United Kingdom); Wilson, J. [The University of Birmingham, School of Physics and Astronomy (United Kingdom)

    2013-12-01

    At the end of 2012 the proton irradiation facility at the CERN PS will shut down for two years. With this in mind, we have been developing a new ATLAS scanning facility at the University of Birmingham Medical Physics cyclotron. With proton beams of energy approximately 30 MeV, fluences corresponding to those of the upgraded Large Hadron Collider (HL-LHC) can be reached conveniently. The facility can be used to irradiate silicon sensors, optical components and mechanical structures (e.g. carbon fibre sandwiches) for the LHC upgrade programme. Irradiations of silicon sensors can be carried out in a temperature controlled cold box that can be scanned through the beam. The facility is described in detail along with the first tests carried out with mini (1×1 cm{sup 2}) silicon sensors.

  20. The Birmingham Irradiation Facility

    Science.gov (United States)

    Dervan, P.; French, R.; Hodgson, P.; Marin-Reyes, H.; Wilson, J.

    2013-12-01

    At the end of 2012 the proton irradiation facility at the CERN PS [1] will shut down for two years. With this in mind, we have been developing a new ATLAS scanning facility at the University of Birmingham Medical Physics cyclotron. With proton beams of energy approximately 30 MeV, fluences corresponding to those of the upgraded Large Hadron Collider (HL-LHC) can be reached conveniently. The facility can be used to irradiate silicon sensors, optical components and mechanical structures (e.g. carbon fibre sandwiches) for the LHC upgrade programme. Irradiations of silicon sensors can be carried out in a temperature controlled cold box that can be scanned through the beam. The facility is described in detail along with the first tests carried out with mini (1×1 cm2) silicon sensors.

  1. The Birmingham Irradiation Facility

    CERN Document Server

    Dervan, P; Hodgson, P; Marin-Reyes, H; Wilson, J

    2013-01-01

    At the end of 2012 the proton irradiation facility at the CERN PS [1] will shut down for two years. With this in mind, we have been developing a new ATLAS scanning facility at the University of Birmingham Medical Physics cyclotron. With proton beams of energy approximately 30 MeV, fluences corresponding to those of the upgraded Large Hadron Collider (HL-LHC) can be reached conveniently. The facility can be used to irradiate silicon sensors, optical components and mechanical structures (e.g. carbon fibre sandwiches) for the LHC upgrade programme. Irradiations of silicon sensors can be carried out in a temperature controlled cold box that can be scanned through the beam. The facility is described in detail along with the first tests carried out with mini (1 x 1 cm^2 ) silicon sensors.

  2. Establishment of a facility for intrusive characterization of transuranic waste at the Nevada Test Site

    International Nuclear Information System (INIS)

    Foster, B.D.; Musick, R.G.; Pedalino, J.P.; Cowley, J.L.; Karney, C.C.; Kremer, J.L.

    1998-01-01

    This paper describes design and construction, project management, and testing results associated with the Waste Examination Facility (WEF) recently constructed at the Nevada Test Site (NTS). The WEF and associated systems were designed, procured, and constructed on an extremely tight budget and within a fast track schedule. Part 1 of this paper focuses on design and construction activities, Part 2 discusses project management of WEF design and construction activities, and Part 3 describes the results of the transuranic (TRU) waste examination pilot project conducted at the WEF. In Part 1, the waste examination process is described within the context of Waste Isolation Pilot Plant (WIPP) characterization requirements. Design criteria are described from operational and radiological protection considerations. The WEF engineered systems are described. These systems include isolation barriers using a glove box and secondary containment structure, high efficiency particulate air (HEPA) filtration and ventilation systems, differential pressure monitoring systems, and fire protection systems. In Part 2, the project management techniques used for ensuring that stringent cost/schedule requirements were met are described. The critical attributes of these management systems are described with an emphasis on team work. In Part 3, the results of a pilot project directed at performing intrusive characterization (i.e., examination) of TRU waste at the WEF are described. Project activities included cold and hot operations. Cold operations included operator training, facility systems walk down, and operational procedures validation. Hot operations included working with plutonium contaminated TRU waste and consisted of waste container breaching, waste examination, waste segregation, data collection, and waste repackaging

  3. An evaluation of the effect of various gloves on polymerization inhibition of elastomeric impression materials: An In vitro study

    Directory of Open Access Journals (Sweden)

    Vinuta Hiremath

    2017-01-01

    Full Text Available Background: Latex protective barriers such as gloves and rubber dam material have been used widely in restorative procedures for crown and bridge. However, the chemical used during latex glove fabrication is thought to inhibit the polymerization of elastomeric impression materials used for impression making which has a detrimental effect on the dimensional accuracy and surface definition of resultant casts used for restorative procedures. The objectives of the study were to examine the surface of different elastomeric impressions on contact with various gloves. Materials and Methods: This clinical study included a total of eighty specimens of two types of the putty elastomeric impression material were hand manipulated by wearing three different gloves materials and is placed on a marked area of a clean and alcohol-treated glass slab at room temperature. The specimens examined for any signs of polymerization inhibition. The specimen will be rated as being “inhibited” if any residue remains on the glass slab and absence of the above will result as “no inhibition.” Results: The results showed no interference with the polymerization inhibition of the selected elastomers followed by the nitrile glove. The latex gloves showed inhibited set of the elastomeric impression material but set after sometime confirming time-dependent inhibition of the impression material. Conclusion: This study shows that the use of latex and sometime nitrile gloves during crown and bridge procedures should be contraindicated and the use of vinyl gloves should be stressed when working with elastomeric impression materials.

  4. Protective gloves for use in high-risk patients: how much do they affect the dexterity of the surgeon?

    Science.gov (United States)

    Phillips, A. M.; Birch, N. C.; Ribbans, W. J.

    1997-01-01

    Twenty-five orthopaedic surgeons underwent eight motor and sensory tests while using four different glove combinations and without gloves. As well as single and double latex, surgeons wore a simple Kevlar glove with latex inside and outside and then wore a Kevlar and Medak glove with latex inside and outside, as recommended by the manufacturers. The effect of learning with each sequence was neutralised by randomising the glove order. The time taken to complete each test was recorded and, where appropriate, error rates were noted. Simple sensory tests took progressively longer to perform so that using the thickest glove combination led to the completion times being doubled. Error rates increased significantly. Tests of stereognosis also took longer and use of the thickest glove combination caused these tests to take three times as long on average. Error rates again increased significantly. However, prolongation of motor tasks was less marked. We conclude that, armed with this quantitative analysis of sensitivity and dexterity impairment, surgeons can judge the relative difficulties that may be incurred as a result of wearing the gloves against the benefits that they offer in protection. PMID:9135240

  5. An Evaluation of the Effect of Various Gloves on Polymerization Inhibition of Elastomeric Impression Materials: An In vitro Study.

    Science.gov (United States)

    Hiremath, Vinuta; Vinayakumar, G; Ragher, Mallikarjuna; Rayannavar, Sounyala; Bembalagi, Mahantesh; Ashwini, B L

    2017-11-01

    Latex protective barriers such as gloves and rubber dam material have been used widely in restorative procedures for crown and bridge. However, the chemical used during latex glove fabrication is thought to inhibit the polymerization of elastomeric impression materials used for impression making which has a detrimental effect on the dimensional accuracy and surface definition of resultant casts used for restorative procedures. The objectives of the study were to examine the surface of different elastomeric impressions on contact with various gloves. This clinical study included a total of eighty specimens of two types of the putty elastomeric impression material were hand manipulated by wearing three different gloves materials and is placed on a marked area of a clean and alcohol-treated glass slab at room temperature. The specimens examined for any signs of polymerization inhibition. The specimen will be rated as being "inhibited" if any residue remains on the glass slab and absence of the above will result as "no inhibition." The results showed no interference with the polymerization inhibition of the selected elastomers followed by the nitrile glove. The latex gloves showed inhibited set of the elastomeric impression material but set after sometime confirming time-dependent inhibition of the impression material. This study shows that the use of latex and sometime nitrile gloves during crown and bridge procedures should be contraindicated and the use of vinyl gloves should be stressed when working with elastomeric impression materials.

  6. Effects of Gloves, Temperature and Their Interaction on Finger, Hand, and Arm Blood Flow and Skin Temperature: A Pilot Study

    Science.gov (United States)

    Hallbech, M. Susan

    1996-01-01

    The objective of this study is to investigate the effects of cold only, commercially available gloves only, and the combination of gloves and cold on the blood flow and surface (skin) temperature of the medial and proximal phalanxes of digit 3, the metacarpal region of the hand, and the forearm.

  7. Interventional Angiography: Radiation Protection for the Examiner by using Lead-free Gloves.

    Science.gov (United States)

    Kamusella, Peter; Scheer, Fabian; Lüdtke, Christopher Wilhelm; Wiggermann, Philipp; Wissgott, Christian; Andresen, Reimer

    2017-07-01

    The radiation exposure to unprotected parts of the body requires special attention for the interventional radiologist. During angiographic procedures, hands are exposed to the direct X-ray beam and scattered radiation. The aim of the study was to evaluate the radiation exposure of examiners hand with the use of lead-free X-ray protective gloves in clinical practice in terms of shielding and sense of touch. The aim of the study was to evaluate the radiation exposure of examiners hand with the use of lead-free X-ray protective gloves in clinical practice in terms of shielding and sense of touch. Phantom measurements were conducted in the direct X-ray beam and the area of scattered radiation with and without shielding. Examiner measurements were determined in interventional angiographies in clinical routine of the lower limb in antegrade puncture technique through the femoral artery. In 24 out of 50 interventions, an elastic natural rubber latex glove with lead-free metal shielding against radiation was used. All measurements were performed with a direct dosimeter. After the intervention, an opinion of the examiner was requested for evaluation of the sense of touch. Phantom measurements; when using the protective glove in the direct X-ray beam, a significant increase of the Dose Area Product (DAP) (1084.2-1603.8 mGy*cm 2 ; 67.6%; pgloves were used, a significant increase of the DAP (6183.2-10462.9 mGy*cm 2 ; 59.1%; pgloves is characterized by a shielding effect against X-ray scattered radiation, without restricting the sense of touch. A significant reduction in radiation doses to the examiner can be accomplished with these gloves in the area of scattered radiation only. If the gloves were used in the direct X-ray beam, especially while the artery puncture was performed, a significant increase of the dose values was observed.

  8. Thermal comfort range of a military cold protection glove: database by thermophysiological simulation.

    Science.gov (United States)

    Zimmermann, Carsten; Uedelhoven, Wolfgang H; Kurz, Bernhard; Glitz, Karl Jochen

    2008-09-01

    The thermal insulation properties of a military wet/cold protection glove of the German Bundeswehr were investigated using the thermophysiological simulation device CYBOR with a heated full-scale hand model. The aim of this study was the physiology related and more reliable estimation of a database for the thermal comfort range of the glove in terms of environmental limit temperatures and maximum safe wearing times (limit times). For that purpose the simulation device CYBOR is equipped with a control feature allowing the simulation of the physiological effect that the blood flow into the hands as the dominant heat source is reduced with decreasing skin temperature (vasoconstriction effect). In the simulation test, the criterion defining the thermal comfort range of the glove was the maintenance of a minimum hand phantom skin temperature of 15 degrees C. For various assumed metabolic rates between 50 and 175 W m(-2) and environmental temperatures down to -22 degrees C, the maximum safe wearing times within the thermal comfort range of the military glove were estimated between only 20 min and almost 1 h. The used simulation scenario for the prediction of environmental limit temperatures, however, tends to deliver too low values in correlation to the estimated limit times and needs further critical consideration. The estimated data concerning the thermal comfort range of the wet/cold protection glove of the German Bundeswehr leads to the recommendation for a use of this model in mild cold climatic regions. The presented thermophysiological simulation procedure for the evaluation of the cold protection properties of gloves in terms of maximum safe wearing times within the thermal comfort range can be a useful tool to establish practical operating instructions for soldiers or civilians acting in cold environments.

  9. Estimated exposure of hands inside the protective gloves used by non-occupational handlers of agricultural pesticides.

    Science.gov (United States)

    Beránková, Martina; Hojerová, Jarmila; Peráčková, Zuzana

    2017-11-01

    Exposure of handlers'/operators' hands is a main route of agricultural pesticides entry into their body. Non-occupational handlers still lack information about appropriate selection of protective gloves to minimize exposure and reduce adverse effects of these chemicals. According to the results of our previous survey, six commercially available, water-resistant gloves commonly used by non-professional gardeners were evaluated for permeation of Acetamiprid, Pirimicarb, and Chlorpyrifos-methyl (Chlorp-m) pesticides by means of in vitro testing. In-use conditions were mimicked as close as possible. Chlorp-m through latex was observed inside the glove from >10 to ⩽15 min; however, Acetamiprid and Pirimicarb through neoprene/latex and all the three pesticides through butyl were not observed inside gloves for the duration of the experiments (the Breakthrough time (BT)>8 h). The 1-h exposure proved the interior glove contamination with Chlorp-m through disposable latex, vinyl, and nitrile gloves (51, 33, and 41% of applied dose (AD), respectively) just as with Acetamiprid and Pirimicarb through latex glove (11 and 14%AD, respectively). However, when storing the used gloves for 4 days after the exposure, no release of the three pesticides from the butyl and Acetamiprid from neoprene/latex gloves was detected. In all other cases, pesticides were found in the interior glove (36-79, 31-63, and 51-81%AD for Acetamiprid, Pirimicarb, and Chlorp-m, respectively). If used repeatedly, gloves contaminated in this way lose their protective function but give the user a false sense of security. The results suggest that (i) water-resistant gloves are not necessarily pesticide resistant; (ii) disposable latex gloves commonly worn by non-professional gardeners provide inadequate protection even for a short-time contact with pesticides; (iii) to assess the efficiency of reusable gloves, not only BT value but also the reservoir/release effect of parent pesticide and its degradation

  10. The Influence of Robotic Assistance on Reducing Neuromuscular Effort and Fatigue during Extravehicular Activity Glove Use

    Science.gov (United States)

    Madden, Kaci E.; Deshpande, Ashish D.; Peters, Benjamin J.; Rogers, Jonathan M.; Laske, Evan A.; McBryan, Emily R.

    2017-01-01

    The three-layered, pressurized space suit glove worn by Extravehicular Activity (EVA) crew members during missions commonly causes hand and forearm fatigue. The Spacesuit RoboGlove (SSRG), a Phase VI EVA space suit glove modified with robotic grasp-assist capabilities, has been developed to augment grip strength in order to improve endurance and reduce the risk of injury in astronauts. The overall goals of this study were to i) quantify the neuromuscular modulations that occur in response to wearing a conventional Phase VI space suit glove (SSG) during a fatiguing task, and ii) determine the efficacy of Spacesuit RoboGlove (SSRG) in reversing the adverse neuromuscular modulations and restoring altered muscular activity to barehanded levels. Six subjects performed a fatigue sequence consisting of repetitive dynamic-gripping interspersed with isometric grip-holds under three conditions: barehanded, wearing pressurized SSG, and wearing pressurized SSRG. Surface electromyography (sEMG) from six forearm muscles (flexor digitorum superficialis (FDS), flexor carpi radialis (FCR), flexor carpi ulnaris (FCU), extensor digitorum (ED), extensor carpi radialis longus (ECRL), and extensor carpi ulnaris (ECU)) and subjective fatigue ratings were collected during each condition. Trends in amplitude and spectral distributions of the sEMG signals were used to derive metrics quantifying neuromuscular effort and fatigue that were compared across the glove conditions. Results showed that by augmenting finger flexion, the SSRG successfully reduced the neuromuscular effort needed to close the fingers of the space suit glove in more than half of subjects during two types of tasks. However, the SSRG required more neuromuscular effort to extend the fingers compared to a conventional SSG in many subjects. Psychologically, the SSRG aided subjects in feeling less fatigued during short periods of intense work compared to the SSG. The results of this study reveal the promise of the SSRG as a

  11. Data glove embedded with 9-axis IMU and force sensing sensors for evaluation of hand function.

    Science.gov (United States)

    Pei-Chi Hsiao; Shu-Yu Yang; Bor-Shing Lin; I-Jung Lee; Chou, Willy

    2015-08-01

    A hand injury can greatly affect a person's daily life. Physicians must evaluate the state of recovery of a patient's injured hand. However, current manual evaluations of hand functions are imprecise and inconvenient. In this paper, a data glove embedded with 9-axis inertial sensors and force sensitive resistors is proposed. The proposed data glove system enables hand movement to be tracked in real-time. In addition, the system can be used to obtain useful parameters for physicians, is an efficient tool for evaluating the hand function of patients, and can improve the quality of hand rehabilitation.

  12. Unwrapping a First Aid Tourniquet From Its Plastic Wrapper With and Without Gloves Worn: A Preliminary Study.

    Science.gov (United States)

    Kragh, John F; Aden, James K; Lambert, Connor D; Moore, Virgil K; Dubick, Michael A

    The purpose of this study was to gather data about unwrapping a packaged limb tourniquet from its plastic wrapper while wearing different types of gloves. Because already unwrapped tourniquets require no time to unwrap, unwrapping data may provide insights into the issue of having tourniquets unwrapped when stowed in a first aid kit of a Serviceperson at war. In a laboratory setting, 36 tests of nine glove groups were performed in which four people, gloved and ungloved, unwrapped tourniquets. Other tourniquets were environmentally exposed for 3 months. All the users successfully unwrapped each tourniquet. Mean times to unwrap by glove group were not significantly different (p = .0961). When mean values of eight experimental groups were compared with that of one control group (i.e., bare hands), results showed no significant difference (p > .07). Mean time was least for bare hands (12 seconds) and most for cold gloves layered under mittens (22 seconds). Among the 36 pairwise comparisons of difference between glove group means, after adjustment for multiple comparisons, no comparison was noted to be statistically significant (p > .052, all 36 pairs). Glove thickness ranged from 0 mm for bare hands to 2.5 mm for cold gloves layered under mittens. By glove group, the thickness-time association was moderate, as tested by linear regression (R2 = 0.6096). The tourniquets exposed to the environment had evidence of rapid photodegradation due to direct exposure to sunlight. Such exposure also destroyed the wrappers. In a preliminary study, different gloves performed similarly when wearers unwrapped a tourniquet from its wrapper. The tourniquet wrappers gave no visible protection from sunlight, and environmental exposure destroyed the wrappers. 2017.

  13. Voronoi Diagrams Without Bounding Boxes

    Science.gov (United States)

    Sang, E. T. K.

    2015-10-01

    We present a technique for presenting geographic data in Voronoi diagrams without having to specify a bounding box. The method restricts Voronoi cells to points within a user-defined distance of the data points. The mathematical foundation of the approach is presented as well. The cell clipping method is particularly useful for presenting geographic data that is spread in an irregular way over a map, as for example the Dutch dialect data displayed in Figure 2. The automatic generation of reasonable cell boundaries also makes redundant a frequently used solution to this problem that requires data owners to specify region boundaries, as in Goebl (2010) and Nerbonne et al (2011).

  14. A soft robotic exomusculature glove with integrated sEMG sensing for hand rehabilitation.

    Science.gov (United States)

    Delph, Michael A; Fischer, Sarah A; Gauthier, Phillip W; Luna, Carlos H Martinez; Clancy, Edward A; Fischer, Gregory S

    2013-06-01

    Stroke affects 750,000 people annually, and 80% of stroke survivors are left with weakened limbs and hands. Repetitive hand movement is often used as a rehabilitation technique in order to regain hand movement and strength. In order to facilitate this rehabilitation, a robotic glove was designed to aid in the movement and coordination of gripping exercises. This glove utilizes a cable system to open and close a patients hand. The cables are actuated by servomotors, mounted in a backpack weighing 13.2 lbs including battery power sources. The glove can be controlled in terms of finger position and grip force through switch interface, software program, or surface myoelectric (sEMG) signal. The primary control modes of the system provide: active assistance, active resistance and a preprogrammed mode. This project developed a working prototype of the rehabilitative robotic glove which actuates the fingers over a full range of motion across one degree-of-freedom, and is capable of generating a maximum 15N grip force.

  15. Using the skin protective lotion IB1 as a substitute for chemical protective gloves.

    Science.gov (United States)

    Ophir, Nimrod; Milk, Nadav; Mayer, Talia; Ravfogel, Shaul; Yavnai, Nirit; Eisenkraft, Arik; Kadar, Tamar; Kassirer, Michael; Rosman, Yossi

    2016-10-01

    We aimed to evaluate the performance of medical personnel in using the IB1 topical protective lotion on their hands and wrists together with standard disposable medical gloves, compared to standard-issued medical chemical protective gloves. This randomized cross-over study included 144 medical personnel. Primary endpoints were time-to-completion of autoinjection; success rate, number of attempts, and time-to-achieve successful endotracheal intubation; time-to-achieve satisfactory tube fixation; time-to-draw and inject the content of an ampoule; and the total time-to-perform all medical procedures. Secondary endpoints included the subjective assessment of convenience to perform these four procedures with each protective measure. Mean time was significantly shorter using IB1 compared to chemical protective gloves for tube fixation, ampoule drawing, and the total time-to-perform all procedures (58.6±22.7 seconds vs. 71.7±29.7; 31.5±21.8 vs. 38.2±19.4; 137.4±56.1 vs. 162.5±63.6, respectively; Pgloves (Pgloves significantly shorten the time-to-perform medical procedures requiring fine motor dexterities and is subjectively more convenient than chemical protective gloves. IB1 should be considered as an appropriate alternative for medical teams in a chemical event. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Skin protection in nursing work : promoting the use of gloves and hand alcohol

    NARCIS (Netherlands)

    Jungbauer, FHW; van der Harst, J.J.; Groothoff, J.W.; Coenraads, PJ

    Nursing has been identified as a wet-work occupation, with a high prevalence of occupational irritant contact dermatitis. Reduction of exposure to skin irritants contributes to the prevention of occupational skin disease in nurses. The role of the use of soap and water, hand alcohol and gloves in

  17. The use of aldehyde indicators to determine glutaraldehyde and alkaline glutaraldehyde contamination in chemical protective gloves.

    Science.gov (United States)

    Vo, Evanly; Zhuang, Zhenzhen

    2009-07-01

    The aim of this study was to assess the use of aldehyde indicator pads for detection of glutaraldehyde and alkaline glutaraldehyde permeation through chemical protective gloves under simulated in-use conditions. The quantitative analysis of glutaraldehyde permeation through a glove material was determined for Metricide, Wavicide, and 50% glutaraldehyde following a solvent-desorption process and gas chromatographic analysis. All glutaraldehyde solutions exhibited >99% adsorption (including both the glutaraldehyde oligomers of the reaction product and the excess glutaraldehyde) on the pads over the spiking range 0.05-5.0 microL. Breakthrough times for protective gloves were determined using the Thermo-Hand test method, and found to range from 76 to 150, from 170 to 230, and from 232 to 300 min for Metricide, Wavicide, and 50% glutaraldehyde, respectively. Glutaraldehyde recovery was calculated and ranged from 61 to 80% for all glutaraldehyde solutions. The mass of glutaraldehyde in these solutions at the time of breakthrough detection ranged from 17 to 18, from 18 to 19, and from 19 to 20 microg/cm(2) for Wavicide, 50% glutaraldehyde solution, and Metricide, respectively. Aldehyde indicator pads and the Thermo-Hand test method together should find utility in detecting, collecting, and quantitatively analyzing glutaraldehyde permeation samples through chemical protective gloves under simulated in-use conditions.

  18. Re-use and life span of gloves | van Palenstein Helderman ...

    African Journals Online (AJOL)

    Re-use and life span of gloves. WH van Palenstein Helderman. Abstract. No Abstract. Full Text: EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about ...

  19. Comparison of mechanical properties of silicone and PVC (polyvinylchloride) cosmetic gloves for articulating hand prostheses

    NARCIS (Netherlands)

    Smit, G.; Plettenburg, D.H.

    2013-01-01

    Current articulating electric and body-powered hands have a lower pinch force (15–34 N) than electric hands with stiff fingers (55–100 N). The cosmetic glove, which covers a hand prosthesis, negatively affects the mechanical efficiency of a prosthesis. The goal of this study is to mechanically

  20. Design of a cosmetic glove stiffness compensation mechanism for toddler-sized hand prostheses

    NARCIS (Netherlands)

    Bos, R.A.; Plettenburg, D.H.

    2017-01-01

    The addition of a cosmetic glove to an upper limb prosthesis has a distinct effect on the cosmetic value, but its viscoelastic behaviour adds a substantial amount of stiffness and hysteresis to the system. As a result, the overall usability of the prosthesis is degraded. A novel negative

  1. Testing Penetration of Epoxy Resin and Diamine Hardeners through Protective Glove and Clothing Materials.

    Science.gov (United States)

    Henriks-Eckerman, Maj-Len; Mäkelä, Erja A; Suuronen, Katri

    2015-10-01

    Efficient, comfortable, yet affordable personal protective equipment (PPE) is needed to decrease the high incidence of allergic contact dermatitis arising from epoxy resin systems (ERSs) in industrial countries. The aim of this study was to find affordable, user-friendly glove and clothing materials that provide adequate skin protection against splashes and during the short contact with ERS that often occurs before full cure. We studied the penetration of epoxy resin and diamine hardeners through 12 glove or clothing materials using a newly developed test method. The tests were carried out with two ERS test mixtures that had a high content of epoxy resin and frequently used diamine hardeners of different molar masses. A drop (50 µl) of test mixture was placed on the outer surface of the glove/clothing material, which had a piece of Fixomull tape or Harmony protection sheet attached to the inner surface as the collection medium. The test times were 10 and 30 min. The collecting material was removed after the test was finished and immersed into acetone. The amounts of diglycidyl ether of bisphenol A (DGEBA), isophorone diamine (IPDA), and m-xylylenediamine (XDA) in the acetone solution were determined by gas chromatography with mass spectrometric detection. The limit for acceptable penetration of XDA, IPDA, and DGEBA through glove materials was set at 2 µg cm(-2). Penetration through the glove materials was 1.4 µg cm(-2) or less. The three tested chemical protective gloves showed no detectable penetration (clothing materials were found to provide adequate protection during short contact with ERS, in the form of, for example, disposable gloves or clothing materials suitable for aprons and as additional protective layers on the most exposed parts of clothing, such as the front of the legs and thighs and under the forearms. Every ERS combination in use should be tested separately to find the best skin protection material, and this can be done by using this simple

  2. Box graphs and singular fibers

    International Nuclear Information System (INIS)

    Hayashi, Hirotaka; Lawrie, Craig; Morrison, David R.; Schäfer-Nameki, Sakura

    2014-01-01

    We determine the higher codimension fibers of elliptically fibered Calabi-Yau fourfolds with section by studying the three-dimensional N=2 supersymmetric gauge theory with matter which describes the low energy effective theory of M-theory compactified on the associated Weierstrass model, a singular model of the fourfold. Each phase of the Coulomb branch of this theory corresponds to a particular resolution of the Weierstrass model, and we show that these have a concise description in terms of decorated box graphs based on the representation graph of the matter multiplets, or alternatively by a class of convex paths on said graph. Transitions between phases have a simple interpretation as “flopping' of the path, and in the geometry correspond to actual flop transitions. This description of the phases enables us to enumerate and determine the entire network between them, with various matter representations for all reductive Lie groups. Furthermore, we observe that each network of phases carries the structure of a (quasi-)minuscule representation of a specific Lie algebra. Interpreted from a geometric point of view, this analysis determines the generators of the cone of effective curves as well as the network of flop transitions between crepant resolutions of singular elliptic Calabi-Yau fourfolds. From the box graphs we determine all fiber types in codimensions two and three, and we find new, non-Kodaira, fiber types for E 6 , E 7 and E 8

  3. Prevalence of manufacturing defects in latex examination gloves used in selected dental practices in central Saudi Arabia.

    Science.gov (United States)

    Al-Swuailem, Abdullah S

    2014-07-01

    To assess the defect rates in latex examination gloves used in selected dental practices in Riyadh, Saudi Arabia. In this cross-sectional study, a total of 796 latex examination gloves were collected from 5 governmental hospitals and 5 private dental practices between April 2012 and May 2012. The gloves were assessed for presence of defects visually (VT) and using water inflation test (WIT). One and 2 sample t-tests were used to assess significant differences in defect rates among each latex brand, and between governmental hospitals and private dental practices. Defects in latex gloves were more likely to be identified using WIT compared with VT (20.2% versus 4.3%, p=0.000). Using WIT, examined latex gloves had a defect rate approximately 8 times the acceptable quality level of 2.5% (20.2%, p=0.000). Using WIT, gloves used in private dental practices had significantly higher defect rates compared with governmental dental clinics (25.6% versus 14.6%, p=0.006). Most latex examination gloves used in the sampled governmental dental clinics and private dental practices in Riyadh had significantly higher preexisting defect rates than acceptable standard levels.

  4. Variable Sweep Transition Flight Experiment (VSTFE)-Parametric Pressure Distribution Boundary Layer Stability Study and Wing Glove Design Task

    Science.gov (United States)

    Rozendaal, Rodger A.

    1986-01-01

    The Variable Sweep Transition Flight Experiment (VSTFE) was initiated to establish a boundary-layer transition data base for laminar flow wing design. For this experiment, full-span upper-surface gloves will be fitted to a variable sweep F-14 aircraft. The results of two initial tasks are documented: a parametric pressure distribution/boundary-layer stability study and the design of an upper-surface glove for Mach 0.8. The first task was conducted to provide a data base from which wing-glove pressure distributions could be selected for glove designs. Boundary-layer stability analyses were conducted on a set of pressure distributions for various wing sweep angles, Mach numbers, and Reynolds number in the range of those anticipated for the flight-test program. The design procedure for the Mach 0.8 glove is described, and boundary-layer stability calculations and pressure distributions are presented both at design and off-design conditions. Also included is the analysis of the clean-up glove (smoothed basic wing) that will be flight-tested initially and the analysis of a Mach 0.7 glove designed at the NASA Langley Research Center.

  5. Monitoring Human Performance During Suited Operations: A Technology Feasibility Study Using EMU Gloves

    Science.gov (United States)

    Bekdash, Omar; Norcross, Jason; McFarland, Shane

    2015-01-01

    Mobility tracking of human subjects while conducting suited operations still remains focused on the external movement of the suit and little is known about the human movement within it. For this study, accelerometers and bend sensitive resistors were integrated into a custom carrier glove to quantify range of motion and dexterity from within the pressurized glove environment as a first stage feasibility study of sensor hardware, integration, and reporting capabilities. Sensors were also placed on the exterior of the pressurized glove to determine if it was possible to compare a glove joint angle to the anatomical joint angle of the subject during tasks. Quantifying human movement within the suit was feasible, with accelerometers clearly detecting movements in the wrist and reporting expected joint angles at maximum flexion or extension postures with repeatability of plus or minus 5 degrees between trials. Bend sensors placed on the proximal interphalangeal and distal interphalangeal joints performed less well. It was not possible to accurately determine the actual joint angle using these bend sensors, but these sensors could be used to determine when the joint was flexed to its maximum and provide a general range of mobility needed to complete a task. Further work includes additional testing with accelerometers and the possible inclusion of hardware such as magnetometers or gyroscopes to more precisely locate the joint in 3D space. We hope to eventually expand beyond the hand and glove and develop a more comprehensive suit sensor suite to characterize motion across more joints (knee, elbow, shoulder, etc.) and fully monitor the human body operating within the suit environment.

  6. Design and test of box girder for a large wind turbine blade

    Energy Technology Data Exchange (ETDEWEB)

    Nielsen, Per H.; Tesauro, A.; Bitsche, R. [Technical Univ. of Denmark. DTU Wind Energy, DTU Risoe Campus, Roskilde (Denmark)] [and others

    2012-09-15

    This report is covering the structural design and full scale test of a box girder as a part of the project ''Demonstration of new blade design using manufacturing process simulations'' supported by the EUDP program. A box girder with a predetermined outer geometry was designed using new inventions, which create an inner structure in the box girder. With a combination of advanced FEM analysis and the inventions it was possible to reduce the material thickness of the cap by up to 40%. The new design of the box girder was manufactured at SSP Technology A/S, where it was demonstrated that the manufacturing process could include the new inventions. Subsequently the box girder was transported to the blade test facility at DTU Wind Energy. A series of test was performed with the blade to investigate the behaviour during loading, and finally the girder was loaded to ultimate failure. The report includes the description of the test setup, the test and an overview over the results from the test performed on the box girder. During the final test the box girder failed at 58 % of the expected ultimate load. Unfortunately, no definite conclusion could be made concerning the failure mechanism. (Author)

  7. Perfuração de Luvas durante Cirurgias Ginecológicas Glove Perforation during Gynecologic Surgeries

    Directory of Open Access Journals (Sweden)

    Eddie Fernando Candido Murta

    2000-05-01

    Full Text Available Objetivo: analisar a incidência de perfuração de luvas cirúrgicas durante atos operatórios ginecológicos. Métodos: estudo prospectivo de 454 luvas usadas em 65 procedimentos utilizando-se o método de pressão de água. Resultados: do total de 454 luvas examinadas, foram verificadas perfurações em 54 (11,9%, sendo estatisticamente significativo o maior número de perfurações em comparação ao grupo controle, uma (1,7% em 60 analisadas (pPurpose: to analyze the frequency of glove perforation during gynecologic surgeries. Methods: a prospective study of 454 gloves used in 65 surgeries by the water pressure method. Results: of a total of 454 gloves, 54 (11.9% had perforations. Comparison with the control group showed p<0.05 (chi² test, 1 (1.7% perforation in 60 gloves tested. Of the total of gloves used in 65 surgeries, 29 (44.6% had perforations, 44 (81% had one perforation and 10 (19% had more than one perforation. The two most common sites of perforations were the index finger, 20 (29.5% and the thumb, 14 (25.9%. Perforation was predominant in the left hand (72.1%. The surgeons were the members of the team with the greatest number of glove perforations. Total hysterectomy was the most frequent surgery in which glove perforations occurred (50% of the cases. Conclusion: the glove perforations occurred with relatively high frequency during gynecologic surgeries. The index finger of the left hand proved to be the most affected region. Among the members of the team, the highest percentage of glove perforations occurred in those of the surgeons. Total hysterectomy had the highest perforation rate.

  8. Lessons from the light-cone box

    CERN Document Server

    Leibbrandt, G

    2000-01-01

    Working in the noncovariant light-cone gauge, we discuss the explicit computation of the 1PI four-point function ("box diagram") in Yang- Mills theory. The complete box diagram which consists of 16 box subdiagrams, 8 lynx subdiagrams and 4 fish subdiagrams, yields both local and nonlocal UV divergent terms. The nonlocal terms are consistent with gauge symmetry and correspond to a nonlocal renormalization of the wave function. (14 refs).

  9. Repackaging SRS Black Box TRU Waste

    International Nuclear Information System (INIS)

    Swale, D. J.; Stone, K.A.; Milner, T. N.

    2006-01-01

    Historically, large items of TRU Waste, which were too large to be packaged in drums for disposal have been packaged in various sizes of custom made plywood boxes at the Savannah River Site (SRS), for many years. These boxes were subsequently packaged into large steel ''Black Boxes'' for storage at SRS, pending availability of Characterization and Certification capability, to facilitate disposal of larger items of TRU Waste. There are approximately 107 Black Boxes in inventory at SRS, each measuring some 18' x 12' x 7', and weighing up to 45,000 lbs. These Black Boxes have been stored since the early 1980s. The project to repackage this waste into Standard Large Boxes (SLBs), Standard Waste Boxes (SWB) and Ten Drum Overpacks (TDOP), for subsequent characterization and WIPP disposal, commenced in FY04. To date, 10 Black Boxes have been repackaged, resulting in 40 SLB-2's, and 37 B25 overpack boxes, these B25's will be overpacked in SLB-2's prior to shipping to WIPP. This paper will describe experience to date from this project

  10. The three-box paradox revisited

    International Nuclear Information System (INIS)

    Ravon, Tamar; Vaidman, Lev

    2007-01-01

    The classical three-box paradox of Kirkpatrick (2003 J. Phys. A: Math. Gen. 36 4891) is compared to the original quantum three-box paradox of Aharonov and Vaidman (1991 J. Phys. A: Math. Gen. 24 2315). It is argued that the quantum three-box experiment is a 'quantum paradox' in the sense that it is an example of a classical task which cannot be accomplished using classical means, but can be accomplished using quantum devices. It is shown that Kirkpatrick's card game is analogous to a different game with a particle in three boxes which does not contain paradoxical features

  11. IMPROVED, FAVORABLE FOR ENVIRONMENT POLYURETHANE COLD-BOX-PROCESS (COLD BOX «HUTTENES-ALBERTUS» .

    Directory of Open Access Journals (Sweden)

    A. Sergini

    2005-01-01

    Full Text Available The results of the laboratory and industrial investigations, the purpose of which is improvement of the classical Cold-box-process, i.e. the process of the slugs hardening in cold boxes, are presented.

  12. VORONOI DIAGRAMS WITHOUT BOUNDING BOXES

    Directory of Open Access Journals (Sweden)

    E. T. K. Sang

    2015-10-01

    Full Text Available We present a technique for presenting geographic data in Voronoi diagrams without having to specify a bounding box. The method restricts Voronoi cells to points within a user-defined distance of the data points. The mathematical foundation of the approach is presented as well. The cell clipping method is particularly useful for presenting geographic data that is spread in an irregular way over a map, as for example the Dutch dialect data displayed in Figure 2. The automatic generation of reasonable cell boundaries also makes redundant a frequently used solution to this problem that requires data owners to specify region boundaries, as in Goebl (2010 and Nerbonne et al (2011.

  13. Frequent Multidrug-Resistant Acinetobacter baumannii Contamination of Gloves, Gowns, and Hands of Healthcare Workers

    Science.gov (United States)

    Morgan, Daniel J.; Liang, Stephen Y.; Smith, Catherine L.; Johnson, J. Kristie; Harris, Anthony D.; Furuno, Jon P.; Thom, Kerri A.; Snyder, Graham M.; Day, Hannah R.; Perencevich, Eli N.

    2010-01-01

    BACKGROUND Multidrug-resistant (MDR) gram-negative bacilli are important nosocomial pathogens. OBJECTIVE To determine the incidence of transmission of MDR Acinetobacter baumannii and Pseudomonas aeruginosa from patients to healthcare workers (HCWs) during routine patient care. DESIGN Prospective cohort study. SETTING Medical and surgical intensive care units. METHODS We observed HCWs who entered the rooms of patients colonized with MDR A. baumannii or colonized with both MDR A. baumannii and MDR P. aeruginosa. We examined their hands before room entry, their disposable gloves and/or gowns upon completion of patient care, and their hands after removal of gloves and/or gowns and before hand hygiene. RESULTS Sixty-five interactions occurred with patients colonized with MDR A. baumannii and 134 with patients colonized with both MDR A. baumannii and MDR P. aeruginosa. Of 199 interactions between HCWs and patients colonized with MDR A. baumannii, 77 (38.7% [95% confidence interval {CI}, 31.9%–45.5%]) resulted in HCW contamination of gloves and/or gowns, and 9 (4.5% [95% CI, 1.6%–7.4%]) resulted in contamination of HCW hands after glove removal before hand hygiene. Of 134 interactions with patients colonized with MDR P. aeruginosa, 11 (8.2% [95% CI, 3.6%–12.9%]) resulted in HCW contamination of gloves and/or gowns, and 1 resulted in HCW contamination of hands. Independent risk factors for contamination with MDR A. baumannii were manipulation of wound dressing (adjusted odds ratio [aOR], 25.9 [95% CI, 3.1–208.8]), manipulation of artificial airway (aOR, 2.1 [95% CI, 1.1–4.0]), time in room longer than 5 minutes (aOR, 4.3 [95% CI, 2.0–9.1]), being a physician or nurse practitioner (aOR, 7.4 [95% CI, 1.6–35.2]), and being a nurse (aOR, 2.3 [95% CI, 1.1–4.8]). CONCLUSIONS Gowns, gloves, and unwashed hands of HCWs were frequently contaminated with MDR A. baumannii. MDR A. baumannii appears to be more easily transmitted than MDR P. aeruginosa and perhaps more

  14. A boxing procedure for corrected cast impressions.

    Science.gov (United States)

    Ansari, I H

    1994-01-01

    This new method for boxing a corrected cast impression for a distal extension removable partial denture improves the procedure. The framework with its impression is seated on the remainder of the cast after anatomic ridges have been removed and luted with sticky wax, and the assembly is inserted into a previously formed thermoplastic box and poured to make a new corrected cast.

  15. 49 CFR 178.515 - Standards for reconstituted wood boxes.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Standards for reconstituted wood boxes. 178.515... wood boxes. (a) The identification code for a reconstituted wood box is 4F. (b) Construction requirements for reconstituted wood boxes are as follows: (1) The walls of boxes must be made of water...

  16. North American box turtles: A natural history

    Science.gov (United States)

    Dodd, C. Kenneth

    2002-01-01

    Once a familiar backyard visitor in many parts of the United States and Mexico, the box turtle is losing the battle against extinction. In North American Box Turtles, C. Kenneth Dodd, Jr., has written the first book-length natural history of the twelve species and subspecies of this endangered animal. This volume includes comprehensive information on the species’ evolution, behavior, courtship and reproduction, habitat use, diet, population structure, systematics, and disease. Special features include color photos of all species, subspecies, and their habitats; a simple identification guide to both living and fossil species; and a summary of information on fossil Terrapene and Native uses of box turtles. End-of-chapter sections highlight future research directions, including the need for long-term monitoring and observation of box turtles within their natural habitat and conservation applications. A glossary and a bibliography of literature on box turtles accompany the text.

  17. Technology as the Crayon Box.

    Science.gov (United States)

    Garcia, Lilia

    2000-01-01

    While arts facilities should be equipped with computers, color scanners, MIDI (Musical Instrument Digital Interface) labs, connective video cameras, and appropriate software, music rooms still need pianos and visual art rooms need traditional art supplies. Dade County (Florida) Schools's pilot teacher assistance projects and arts-centered schools…

  18. The effects of compression gloves on hand symptoms and hand function in rheumatoid arthritis and hand osteoarthritis: a systematic review.

    Science.gov (United States)

    Hammond, Alison; Jones, Vivienne; Prior, Yeliz

    2016-03-01

    to evaluate the effects of compression gloves in adults with rheumatoid arthritis and hand osteoarthritis. Systematic review of randomized controlled trials identified from MEDLINE, CINAHL, AMED, PEDro, OT Seeker, The Cochrane Library, ISI Web of Knowledge, Science Direct and PubMed from their inceptions to January 2015. Methodological quality of identified trials was evaluated using the PEDro scale by three independent assessors. Effects were summarized descriptively. Four trials (n=8-24; total n=74), comparing night wear of full-length finger compression gloves with placebo gloves, were assessed. Three were of moderate (PEDro score 4-5) and one low (score 3) methodological quality. Effect sizes or standardized mean differences could not be calculated to compare trials due to poor data reporting. In rheumatoid arthritis, finger joint swelling was significantly reduced, but results for pain and stiffness were inconclusive and no differences in grip strength and dexterity were identified. One study reported similar effects in pain, stiffness and finger joint swelling from both compression and thermal placebo gloves. Only one study evaluated gloves in hand osteoarthritis (n=5) with no differences. All the trials identified were small with a high risk of Type I and II errors. Evidence for the effectiveness of compression gloves worn at night is inconclusive in rheumatoid arthritis and hand osteoarthritis. © The Author(s) 2015.

  19. Protection during production: Problems due to prevention? Nail and skin condition after prolonged wearing of occlusive gloves.

    Science.gov (United States)

    Weistenhöfer, Wobbeke; Uter, Wolfgang; Drexler, Hans

    2017-01-01

    Wearing of occlusive gloves during the whole working shift is considered a risk factor for developing hand eczema, similar to wet work. Moreover, the increased hydration due to glove occlusion may lead to brittle nails. Two hundred and seventy clean room workers, wearing occlusive gloves for prolonged periods, and 135 administrative employees not using gloves were investigated. This included a dermatological examination of the nails and the hands, using the Hand Eczema ScoRe for Occupational Screening (HEROS), measurement of transepidermal water loss (TEWL), and a standardized interview. Of the clean room workers, 39%, mainly women, reported nail problems, mostly brittle nails with onychoschisis. Skin score values showed no significant differences between HEROS values of both groups. TEWL values of exposed subjects were similar to TEWL values of controls 40 min after taking off the occlusive gloves. In a multiple linear regression analysis, male gender and duration of employment in the clean room were associated with a significant increase in TEWL values. The effect of occlusion on TEWL seems to be predominantly transient and not be indicative of a damaged skin barrier. This study confirmed the results of a previous investigation showing no serious adverse effect of wearing of occlusive gloves on skin condition without exposure to additional hazardous substances. However, occlusion leads to softened nails prone to mechanical injury. Therefore, specific prevention instructions are required to pay attention to this side effect of occlusion.

  20. Hand hygiene with alcohol hand rub and gloves reduces the incidence of late onset sepsis in preterm neonates.

    Science.gov (United States)

    Janota, Jan; Šebková, Sylva; Višňovská, Magda; Kudláčková, Jana; Hamplová, Drahomíra; Zach, Jiří

    2014-10-01

    To assess the impact of a hand hygiene protocol, using hand washing, alcohol hand rub and gloves when caring for preterm infants born after 31 weeks of gestation, on the incidence of neonatal late onset sepsis (LOS). All babies delivered between 32 + 0 and 36 + 6 weeks gestation and admitted to the neonatal intensive care unit during a 14-month period were included. We followed a hand hygiene protocol with hand washing and alcohol hand rub (hand rub period) for the first 7 months and a protocol of hand washing, alcohol hand rub and gloves (gloves period) for the second 7 months. The hand rub and gloves groups consisted of 111 and 89 patients, respectively. Five patients were diagnosed with a total of six episodes of LOS in the hand rub group, and the incidence of LOS during the hand rub period was 2.99/1000 hospital days and 54.1/1000 admissions. There were no patients diagnosed with LOS during the gloves period (significant decrease, p = 0.028). Using a hand hygiene protocol with hand washing, hand rub and gloves significantly reduced the incidence of LOS in preterm newborns, and the results suggest that it may produce a sustained improvement in the infection rate. ©2014 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  1. Occlusive gloves and skin conditions: is there a problem? Results of a cross-sectional study in a semiconductor company.

    Science.gov (United States)

    Weistenhöfer, W; Wacker, M; Bernet, F; Uter, W; Drexler, H

    2015-04-01

    Although there is poor scientific evidence that working with occlusive gloves is as damaging as wet work, prolonged glove occlusion is considered to be a risk factor for developing hand eczema similar to wet work. To assess the effects of wearing occlusive gloves during the whole working day, without exposure to any additional hazardous substances, on skin condition and skin barrier function. We investigated 323 employees of a semiconductor production company in Germany: 177 clean-room workers wearing occlusive gloves during the whole shift (exposed group) and 146 employees working in administration (control group). A standardized interview was performed, the skin condition of both hands was studied using the quantitative skin score HEROS, and transepidermal water loss (TEWL) and stratum corneum hydration were measured. There was no significant difference in skin condition between the two subgroups. Values for TEWL and corneometry were significantly higher in exposed participants (P gloves at least 30 min before the measurement. Hence, the effect of occlusion on skin barrier function seems to be transient. Prolonged wearing of occlusive gloves with clean hands and without exposure to additional hazardous substances does not seem to affect the skin negatively. © 2014 British Association of Dermatologists.

  2. The impact of the use of different types of gloves and bare hands for preparation of clean surgical instruments 1

    Science.gov (United States)

    Bruna, Camila Quartim de Moraes; de Souza, Rafael Queiroz; Massaia, Irineu Francisco Silva; Cruz, Áurea Silveira; Graziano, Kazuko Uchikawa

    2016-01-01

    ABSTRACT Objectives: to determine if there are differences on the safety of the preparation of clean surgical instruments using different types of gloves and bare hands and evaluate the microbiological load of these preparations without gloves. Method: laboratory procedure with a pragmatic approach, in which the samples were handled with different types of gloves and bare hands. In addition, cytotoxicity assays were carried out by means of the agar diffusion method. Further samples were subjected to microbiological analysis after being handled without gloves. Results: none of the samples showed cytotoxic effect. All microbiological cultures showed growth of microorganisms, but no microorganism has been recovered after autoclaving. Conclusion: there were no differences in the cytotoxic responses regarding the use of different types of gloves and bare hands in the handling of clean surgical instruments, which could entail iatrogenic risk. It is noteworthy that the use of gloves involves increase in the costs of process and waste generation, and the potential allergenic risk to latex. PMID:27737375

  3. AQUACEL® Ag BURN glove and silver sulfadiazine for the treatment of partial thickness hand burns: A retrospective review

    Directory of Open Access Journals (Sweden)

    Moti Harats

    2016-01-01

    Full Text Available Background: Loss of hand function has a detrimental impact on the physical and psychosocial functioning of those with hand burns. Of prime importance is the maintenance of range of movement (ROM. Subsequently, an ideal hand dressing needs to allow for full ROM, be comfortable, and facilitate healing. However, hand burns present complex challenges for burn clinicians with the dressing of choice remaining controversial. Patients and Methods: This retrospective review was undertaken to determine the effectiveness of the AQUACEL® Ag BURN glove as compared to silver sulfadiazine (SSD; standard care in patients with partial thickness hand burns. The average total body surface area % was 14.6% with an average age of 37 years. Eight hands were dressed with an AQUACEL® Ag BURN glove and eight were dressed with SSD. Results: Pain scores were reduced in those with the glove compared to those who were treated with SSD dressing. Mobility of the hand with the glove was reduced compared to the patients treated with SSD. The glove cost including outer dressings was $330 US, this is compared to $432 US for the SSD dressing based on the average reepithelization rate of 15 days, and translates into a financial saving of approximately $100 US per patient and further reduces workload and resources. Conclusion: The use of a hydrofiber silver impregnated glove for partial thickness hand burns, has clinical significance in the outpatient setting reducing the need for hospitalization, and the amount of dressing changes required.

  4. Development and performance assessment of electrically heating gloves with smart temperature control function.

    Science.gov (United States)

    Ma, Nini; Lu, Yehu; Xu, Fanfei; Dai, Hongqin

    2018-03-27

    A pair of lightweight electrically heating gloves (EHG) with smart temperature control function was developed. To evaluate thermoregulation properties of EHG, human trials were conducted in a climate chamber (2.5 °C, 60% RH). The changes in skin temperature of all fingers and opisthenar and the subjective thermal sensation were recorded in 60 min. The effects of two air velocities (i.e., 0.17 m/s and 0.50 m/s) on the cold protective performance of EHG in scenarios of heating and control were also investigated. For heating scenarios, skin temperature and thermal sensation at all fingers and opisthenar were found significantly higher than those in control conditions. Moreover, the air velocity at 0.50 m/s greatly reduced cold protective performance of the gloves. The research findings can be applied to improve thermal comfort and extend working time for persons in cold environments.

  5. Influence on grip of knife handle surface characteristics and wearing protective gloves.

    Science.gov (United States)

    Claudon, Laurent

    2006-11-01

    Ten subjects were asked to apply maximum torques on knife handles with either their bare hand or their hand wearing a Kevlar fibre protective glove. Four knife handles (2 roughnesses, 2 hardnesses) were tested. Surface electromyograms of 6 upper limb and shoulder muscles were recorded and subject opinions on both knife handle hardness and friction in the hand were also assessed. The results revealed the significant influence of wearing gloves (pgloves greatly increased the torque independently of the other two parameters. Under the bare hand condition, a 90 degrees ShA slightly rough handle provided the greatest torque. Subject opinion agreed with the observed effects on recorded torque values except for the hardness factor, for which a preference for the 70 degrees ShA value over the 90 degrees ShA value emerged.

  6. Sensing Performance of a Vibrotactile Glove for Deaf-Blind People

    Directory of Open Access Journals (Sweden)

    Albano Carrera

    2017-03-01

    Full Text Available This paper presents a glove designed to assess the viability of communication between a deaf-blind user and his/her interlocutor through a vibrotactile device. This glove is part of the TactileCom system, where communication is bidirectional through a wireless link, so no contact is required between the interlocutors. Responsiveness is higher than with letter by letter wording. The learning of a small set of concepts is simpler and the amount learned can be increased at the user’s convenience. The number of stimulated fingers, the keying frequencies and finger response were studied. Message identification rate was 97% for deaf-blind individuals and 81% for control subjects. Identification by single-finger stimulation was better than by multiple-finger stimulation. The interface proved suitable for communication with deaf-blind individuals and can also be used in other conditions, such as multilingual or noisy environments.

  7. A knitted glove sensing system with compression strain for finger movements

    Science.gov (United States)

    Ryu, Hochung; Park, Sangki; Park, Jong-Jin; Bae, Jihyun

    2018-05-01

    Development of a fabric structure strain sensor has received considerable attention due to its broad application in healthcare monitoring and human–machine interfaces. In the knitted textile structure, it is critical to understand the surface structural deformation from a different body motion, inducing the electrical signal characteristics. Here, we report the electromechanical properties of the knitted glove sensing system focusing on the compressive strain behavior. Compared with the electrical response of the tensile strain, the compressive strain shows much higher sensitivity, stability, and linearity via different finger motions. Additionally, the sensor exhibits constant electrical properties after repeated cyclic tests and washing processes. The proposed knitted glove sensing system can be readily extended to a scalable and cost-effective production due to the use of a commercialized manufacturing system.

  8. Wearable Flexible and Stretchable Glove Biosensor for On-Site Detection of Organophosphorus Chemical Threats

    Science.gov (United States)

    2017-03-03

    right) linear stretch; scale bar, 10 mm. (D) On-glove swiping protocol for sampling chemical threat residues from tomato and stainless steel surfaces. (E...xylene (8 mL), mixed thoroughly in an ultrasonic bath, and then homogenized in a shaker for 2 h. Thereafter, the carbon/PS-PI-PS composite ink was...was cast on the surface of the fruits and vegetables (apples, grapes, green peppers, and tomatoes ) and other target surfaces, such as wood, stainless

  9. Factors influencing the perception of roughness in manual exploration: Do medical gloves reduce cutaneous sensibility?

    OpenAIRE

    Mylon, P.T.; Buckley-Johnstone, L.; Lewis, R.; Carre, M.J.; Martin, N.

    2015-01-01

    A new roughness perception test was designed to evaluate cutaneous sensibility. Blindfolded subjects explored a sample of sandpaper using one of two methods: stroking the sample (dynamic method) or applying pressure (static method). A range of samples of various grades were presented in a random order, and subjects scored each one in terms of perceived roughness. Each subject performed the test in three conditions – wearing latex and nitrile examination gloves and bare-handed. Mean normalised...

  10. Augmenting white cane reliability using smart glove for visually impaired people.

    Science.gov (United States)

    Bernieri, Giuseppe; Faramondi, Luca; Pascucci, Federica

    2015-08-01

    The independent mobility problem of visually impaired people has been an active research topic in biomedical engineering: although many smart tools have been proposed, traditional tools (e.g., the white cane) continue to play a prominent role. In this paper a low cost smart glove is presented: the key idea is to minimize the impact in using it by combining the traditional tools with a technological device able to improve the movement performance of the visually impaired people.

  11. Final report for Allied-Signal Aerospace Company, Kansas City Division on protective glove permeation analysis

    International Nuclear Information System (INIS)

    Swearengen, P.M.; Johnson, J.S.; Priante, S.J.

    1990-01-01

    We conducted 25 separate glove fabric permeation studies during this project. The permeations were carried out in the small (1 inch) glass ASTM cell. One other permeation study was carded out with a large (two inch) modified ASTM cell for comparison with the small cell results. We also compared the LLNL procedure from both large and small cells with the standard ASTM test procedure which uses a liquid solution on the breakthrough side of the fabric (the liquid is then sampled on a periodic basis). In all comparisons we observed a close-correlation in breakthrough times between the two procedures and the two cell sizes. In the course of this study, we tested ten different glove materials. These included neoprene (original ASTM round-robin sheet stock, 16 mil thickness), Edmont Sol-Vex (nitrile), Pioneer nitrile, Pioneer Pylox (polyvinyl chloride), North Viton (trademark for fluoroelastomers), North SilverShield (Norfoil, trademark for a flexible metallized laminate), Safety 4 4H (patented plastic laminate), and QRP PolyTuff (polyurethane) 20G-2000 (5 mil), 23G-2300 (1.5 mil), and 25G-2500 (1.5 mil). Three of the glove materials, Viton and Silver Shield (North), and 4H (Safety 4), did not allow any permeation measurable by our system to either 1,2-dichloroethane or 3% diphenylmercury (in 1,2-dichloroethane) for a period greater than six hours. A fourth material, QRP Poly Tuff 2OG-2000, did not allow any measurable penetration of Asilamine (an aromatic diamine) for a time pedod of greater than 4 hours. Breakthrough times and curves were obtained for all other tested materials. Eleven different chemicals were used to challenge the glove materials. These included acetone, Asilamine, 1,2-dichloroethane, dichloromethane, isopropyl alcohol, a mixture of 3% diphenylmercury in 1,2-dichloroethane (w/w), phenol, and lso Verre Stripper, 4,4'-methylenedianil (MDA), 1,3-phenylenediamine (MPDA), and Shell Epon (R) curing agent Z

  12. Final report for Allied-Signal Aerospace Company, Kansas City Division on protective glove permeation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Swearengen, P.M.; Johnson, J.S.; Priante, S.J. [Lawrence Livermore National Lab., CA (United States)

    1990-06-22

    We conducted 25 separate glove fabric permeation studies during this project. The permeations were carried out in the small (1 inch) glass ASTM cell. One other permeation study was carded out with a large (two inch) modified ASTM cell for comparison with the small cell results. We also compared the LLNL procedure from both large and small cells with the standard ASTM test procedure which uses a liquid solution on the breakthrough side of the fabric (the liquid is then sampled on a periodic basis). In all comparisons we observed a close-correlation in breakthrough times between the two procedures and the two cell sizes. In the course of this study, we tested ten different glove materials. These included neoprene (original ASTM round-robin sheet stock, 16 mil thickness), Edmont Sol-Vex (nitrile), Pioneer nitrile, Pioneer Pylox (polyvinyl chloride), North Viton (trademark for fluoroelastomers), North SilverShield (Norfoil, trademark for a flexible metallized laminate), Safety 4 4H (patented plastic laminate), and QRP PolyTuff (polyurethane) 20G-2000 (5 mil), 23G-2300 (1.5 mil), and 25G-2500 (1.5 mil). Three of the glove materials, Viton and Silver Shield (North), and 4H (Safety 4), did not allow any permeation measurable by our system to either 1,2-dichloroethane or 3% diphenylmercury (in 1,2-dichloroethane) for a period greater than six hours. A fourth material, QRP Poly Tuff 2OG-2000, did not allow any measurable penetration of Asilamine (an aromatic diamine) for a time pedod of greater than 4 hours. Breakthrough times and curves were obtained for all other tested materials. Eleven different chemicals were used to challenge the glove materials. These included acetone, Asilamine, 1,2-dichloroethane, dichloromethane, isopropyl alcohol, a mixture of 3% diphenylmercury in 1,2-dichloroethane (w/w), phenol, and lso Verre Stripper, 4,4`-methylenedianil (MDA), 1,3-phenylenediamine (MPDA), and Shell Epon (R) curing agent Z.

  13. Utilizing Glove-Based Gestures and a Tactile Vest Display for Covert Communications and Robot Control

    Science.gov (United States)

    2014-06-01

    dynamic time warping (Hu et al., 2009; Wu et al., 2010), and artificial neural networks (Oz and Leu, 2007). Hand and body gestures can be...of a standard tactical glove with accelerometers embedded within each finger, and an accelerometer, gyroscope, and digital compass embedded in the...Spatial ability scores did not correlate significantly with any robot controller performance measure. Spatial ability scores were also analyzed as a

  14. A Design Approach to Engage with Audience with Wearable Musical Instruments: Sound Gloves

    OpenAIRE

    Lai, Chi-Hsia; Tahiroglu, Koray

    2012-01-01

    This paper addresses the issue of engaging the audience with new musical instruments in live performance context. We introduce design concerns that we consider influential to enhance the communication flow between the audience and the performer. We also propose and put in practice a design approach that considers the use of performance space as a way to engage with the audience. A collaborative project, Sound Gloves, presented here exemplifies such a concept by dissolving the space between pe...

  15. ­The Carnegie Quick Deploy Box (QDB) for use with broadband and intermediate period sensors

    Science.gov (United States)

    Wagner, L. S.; Roman, D.; Bartholomew, T.; Golden, S.; Schleigh, B.

    2017-12-01

    Recent data processing advances have increased the call for dense recordings of teleseismic data. However, traditional broadband field installations typically comprise 1) a sensor vault 2) a field box to hold the recording and power systems, and 3) a solar panel mount. The construction of these installations is time consuming and requires bulky construction materials, limiting the number of stations that can be installed from a single vehicle without repeated trips to a storage facility. Depending on the deployment location, watertight containers for both vault and field box can be difficult to find, resulting in a loss of data due to flooding. Recent technological improvements have made possible the direct burial of sensors (no vault required) and a reduction in the size of the solar panels needed to run a station. With support from the Brinson Foundation, we take advantage of these advances to create a field box/shipping container that will greatly simplify these types of seismic deployments. The goal of the Carnegie Quick Deploy Box (QDB) is to have everything needed for an intermediate period station install (except battery and shovel) contained in a single box for shipment, and to be able to leave everything (except the shovel) in that box when the station is deployed. The box is small enough ( 13"x13"x21") and lightweight enough (solar panel mount can be attached securely to the top of the box, but it can also be pole mounted with U-bolts or hose clamps. The sensor can be direct-buried. The sensor cable and solar panel cable plug into watertight bulkhead-fitted plugs on the outside of the box that are in turn plugged into the digitizer and power regulator inside the box. Our prototype boxes (Pelican Cases) have proved watertight when submerged for days. This equipment has been tested in Alaska in winter and Nicaragua in summer without failure due to flooding or power. The cost for parts for a single box (not including sensor cable, sensor, or digitizer) is

  16. Probe and Sensors Development for Level Measurement of Fats, Oils and Grease in Grease Boxes

    Directory of Open Access Journals (Sweden)

    José Faria

    2016-09-01

    Full Text Available The wide spread of food outlets has become an environmental and sanitation infrastructure problem, due to Fats, Oils and Grease (FOG. A grease box is used at the industrials facilities to collect the FOG, in a specific time window, while its quality is good for recycling (e.g., biodiesel and it is economically valuable. After this period, it will be disposed at a cost. For the proper management of the grease boxes, it is necessary to know the quantity of FOG inside the boxes, which is a major problem, as the boxes are sealed and permanently filled with water. The lack of homogeneity of the FOG renders it not detectable by current probes for level detection in liquids. In this article, the design, development and testing of a set of probes for FOG level measurement, based on the principles used in sensors for the detection of liquids inside containers, is described. The most suitable probe, based on the capacitance principle, together with the necessary hardware and software modules for data acquisition and transmission, was developed and tested. After the development phase, the probe was integrated on a metropolitan system for FOG collection and grease box management in partnership with a grease box management company.

  17. Achieving safe hands-on defibrillation using electrical safety gloves--a clinical evaluation.

    Science.gov (United States)

    Deakin, Charles D; Thomsen, Jakob E; Løfgren, Bo; Petley, Graham W

    2015-05-01

    Safe hands-on defibrillation (HOD) will allow uninterrupted chest compression during defibrillation and may improve resuscitation success. We tested the ability of electrical insulating gloves to protect the rescuer during HOD using a 'worst case' electrical scenario. Leakage current flowing from the patient to the 'rescuer' during antero-lateral defibrillation of patients undergoing elective cardioversion was measured. The 'rescuer' maintained firm (20 kgf) contact with the patient during defibrillation, wearing Class 1 electrical insulating gloves while simulating an inadvertent contact with the patient, through an additional wired contact between 'rescuer' and patient. Data from 61 shocks from 43 different patients were recorded. The median leakage current from all defibrillations was 20.0 μA, (range: 2.0-38.5). In total, 18 of the shocks were delivered at 360 J and had a median leakage current of 27.0 μA (range: 14.3-38.5). When using Class 1 electrical insulating gloves for hands-on defibrillation, rescuer leakage current is significantly below the 1 mA safe threshold, allowing safe hands-on defibrillation if the rescuer makes only one other point of contact with the patient. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  18. Student perceptions and effectiveness of an innovative learning tool: Anatomy Glove Learning System.

    Science.gov (United States)

    Lisk, Kristina; McKee, Pat; Baskwill, Amanda; Agur, Anne M R

    2015-01-01

    A trend in anatomical education is the development of alternative pedagogical approaches to replace or complement experiences in a cadaver laboratory; however, empirical evidence on their effectiveness is often not reported. This study aimed to evaluate the effectiveness of Anatomy Glove Learning System (AGLS), which enables students to learn the relationship between hand structure and function by drawing the structures onto a worn glove with imprinted bones. Massage therapy students (n = 73) were allocated into two groups and drew muscles onto either: (1) the glove using AGLS instructional videos (3D group); or (2) paper with palmar/dorsal views of hand bones during an instructor-guided activity (2D group). A self-confidence measure and knowledge test were completed before, immediately after, and one-week following the learning conditions. Self-confidence of hand anatomy in the 3D group gradually increased (3.2/10, 4.7/10, and 4.8/10), whereas self-confidence in the 2D group began to decline one-week later (3.2/10, 4.4/10, and 3.9/10). Knowledge of hand anatomy improved in both groups immediately after learning, (P learning tool (mean = 8.6 ± 2.2). This study provides evidence demonstrating that AGLS and the traditional 2D learning approach are equally effective in promoting students' self-confidence and knowledge of hand anatomy. © 2014 American Association of Anatomists.

  19. Gesture recognition based on computer vision and glove sensor for remote working environments

    Energy Technology Data Exchange (ETDEWEB)

    Chien, Sung Il; Kim, In Chul; Baek, Yung Mok; Kim, Dong Su; Jeong, Jee Won; Shin, Kug [Kyungpook National University, Taegu (Korea)

    1998-04-01

    In this research, we defined a gesture set needed for remote monitoring and control of a manless system in atomic power station environments. Here, we define a command as the loci of a gesture. We aim at the development of an algorithm using a vision sensor and glove sensors in order to implement the gesture recognition system. The gesture recognition system based on computer vision tracks a hand by using cross correlation of PDOE image. To recognize the gesture word, the 8 direction code is employed as the input symbol for discrete HMM. Another gesture recognition based on sensor has introduced Pinch glove and Polhemus sensor as an input device. The extracted feature through preprocessing now acts as an input signal of the recognizer. For recognition 3D loci of Polhemus sensor, discrete HMM is also adopted. The alternative approach of two foregoing recognition systems uses the vision and and glove sensors together. The extracted mesh feature and 8 direction code from the locus tracking are introduced for further enhancing recognition performance. MLP trained by backpropagation is introduced here and its performance is compared to that of discrete HMM. (author). 32 refs., 44 figs., 21 tabs.

  20. The Language of Glove: Wireless gesture decoder with low-power and stretchable hybrid electronics.

    Science.gov (United States)

    O'Connor, Timothy F; Fach, Matthew E; Miller, Rachel; Root, Samuel E; Mercier, Patrick P; Lipomi, Darren J

    2017-01-01

    This communication describes a glove capable of wirelessly translating the American Sign Language (ASL) alphabet into text displayable on a computer or smartphone. The key components of the device are strain sensors comprising a piezoresistive composite of carbon particles embedded in a fluoroelastomer. These sensors are integrated with a wearable electronic module consisting of digitizers, a microcontroller, and a Bluetooth radio. Finite-element analysis predicts a peak strain on the sensors of 5% when the knuckles are fully bent. Fatigue studies suggest that the sensors successfully detect the articulation of the knuckles even when bent to their maximal degree 1,000 times. In concert with an accelerometer and pressure sensors, the glove is able to translate all 26 letters of the ASL alphabet. Lastly, data taken from the glove are used to control a virtual hand; this application suggests new ways in which stretchable and wearable electronics can enable humans to interface with virtual environments. Critically, this system was constructed of components costing less than $100 and did not require chemical synthesis or access to a cleanroom. It can thus be used as a test bed for materials scientists to evaluate the performance of new materials and flexible and stretchable hybrid electronics.

  1. The Language of Glove: Wireless gesture decoder with low-power and stretchable hybrid electronics.

    Directory of Open Access Journals (Sweden)

    Timothy F O'Connor

    Full Text Available This communication describes a glove capable of wirelessly translating the American Sign Language (ASL alphabet into text displayable on a computer or smartphone. The key components of the device are strain sensors comprising a piezoresistive composite of carbon particles embedded in a fluoroelastomer. These sensors are integrated with a wearable electronic module consisting of digitizers, a microcontroller, and a Bluetooth radio. Finite-element analysis predicts a peak strain on the sensors of 5% when the knuckles are fully bent. Fatigue studies suggest that the sensors successfully detect the articulation of the knuckles even when bent to their maximal degree 1,000 times. In concert with an accelerometer and pressure sensors, the glove is able to translate all 26 letters of the ASL alphabet. Lastly, data taken from the glove are used to control a virtual hand; this application suggests new ways in which stretchable and wearable electronics can enable humans to interface with virtual environments. Critically, this system was constructed of components costing less than $100 and did not require chemical synthesis or access to a cleanroom. It can thus be used as a test bed for materials scientists to evaluate the performance of new materials and flexible and stretchable hybrid electronics.

  2. The Language of Glove: Wireless gesture decoder with low-power and stretchable hybrid electronics

    Science.gov (United States)

    O’Connor, Timothy F.; Fach, Matthew E.; Miller, Rachel; Root, Samuel E.; Mercier, Patrick P.

    2017-01-01

    This communication describes a glove capable of wirelessly translating the American Sign Language (ASL) alphabet into text displayable on a computer or smartphone. The key components of the device are strain sensors comprising a piezoresistive composite of carbon particles embedded in a fluoroelastomer. These sensors are integrated with a wearable electronic module consisting of digitizers, a microcontroller, and a Bluetooth radio. Finite-element analysis predicts a peak strain on the sensors of 5% when the knuckles are fully bent. Fatigue studies suggest that the sensors successfully detect the articulation of the knuckles even when bent to their maximal degree 1,000 times. In concert with an accelerometer and pressure sensors, the glove is able to translate all 26 letters of the ASL alphabet. Lastly, data taken from the glove are used to control a virtual hand; this application suggests new ways in which stretchable and wearable electronics can enable humans to interface with virtual environments. Critically, this system was constructed of components costing less than $100 and did not require chemical synthesis or access to a cleanroom. It can thus be used as a test bed for materials scientists to evaluate the performance of new materials and flexible and stretchable hybrid electronics. PMID:28700603

  3. A human factors approach towards the design of a new glovebox glove for Los Alamos National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Oka, Jude M. [Los Alamos National Laboratory

    2012-08-06

    Present day glovebox gloves at Los Alamos National Laboratory (LANL) are underdeveloped and ergonomically inaccurate. This problem results in numerous sprain and strain injuries every year for employees who perform glovebox work. In addition to injuries, using the current glovebox glove design also contributes to breaches and contamination. The current glove used today at LANL has several problems: (1) The length of the fingers is incorrect, (2) the web spacing between the fingers is nonexistent, (3) the angles between each digit on the finger are incorrect, (4) the thumb is placed inaccurately, and (5) the length of the hand is incorrect. These problems present a need to correct the current glove design to decrease the risk of injuries, breaches, and contamination. Anthropometrics were researched to help find the best range of hand measurements to fix the current glove design. Anthropometrics is the measure of the human physical variation. Anthropometrics for this study were gathered from the American National Survey (ANSUR) data that was conducted by the U.S Army in 1988. The current glovebox glove uses anthropometrics from the 95th to 105th percentile range which is too large so the new gloves are going to implement data from a smaller range of percentile groups. The 105th percentile range represents measurements that exceed the human population but are needed to fit certain circumstance such as wearing several under gloves within the glovebox gloves. Anthropometrics used in this study include: 105th percentile measurements for joint circumference which was unchanged because the room for under gloves plus ease of hand insertion and extraction is needed, 80th percentile measurements for crotch length to allow workers to reach the web spacing in the glove, 20th percentile measurements for finger length to allow workers to reach the end of the glove, standard 10.5cm hand breadth to allow more room to accommodate under gloves, 45 degrees abduction angle for the

  4. CSciBox: An Intelligent Assistant for Dating Ice and Sediment Cores

    Science.gov (United States)

    Finlinson, K.; Bradley, E.; White, J. W. C.; Anderson, K. A.; Marchitto, T. M., Jr.; de Vesine, L. R.; Jones, T. R.; Lindsay, C. M.; Israelsen, B.

    2015-12-01

    CSciBox is an integrated software system for the construction and evaluation of age models of paleo-environmental archives. It incorporates a number of data-processing and visualization facilities, ranging from simple interpolation to reservoir-age correction and 14C calibration via the Calib algorithm, as well as a number of firn and ice-flow models. It employs modern database technology to store paleoclimate proxy data and analysis results in an easily accessible and searchable form, and offers the user access to those data and computational elements via a modern graphical user interface (GUI). In the case of truly large data or computations, CSciBox is parallelizable across modern multi-core processors, or clusters, or even the cloud. The code is open source and freely available on github, as are one-click installers for various versions of Windows and Mac OSX. The system's architecture allows users to incorporate their own software in the form of computational components that can be built smoothly into CSciBox workflows, taking advantage of CSciBox's GUI, data importing facilities, and plotting capabilities. To date, BACON and StratiCounter have been integrated into CSciBox as embedded components. The user can manipulate and compose all of these tools and facilities as she sees fit. Alternatively, she can employ CSciBox's automated reasoning engine, which uses artificial intelligence techniques to explore the gamut of age models and cross-dating scenarios automatically. The automated reasoning engine captures the knowledge of expert geoscientists, and can output a description of its reasoning.

  5. Facilities & Leadership

    Data.gov (United States)

    Department of Veterans Affairs — The facilities web service provides VA facility information. The VA facilities locator is a feature that is available across the enterprise, on any webpage, for the...

  6. MADS-box gene evolution - structure and transcription patterns

    DEFF Research Database (Denmark)

    Johansen, Bo; Pedersen, Louise Buchholt; Skipper, Martin

    2002-01-01

    Mads-box genes, ABC model, Evolution, Phylogeny, Transcription patterns, Gene structure, Conserved motifs......Mads-box genes, ABC model, Evolution, Phylogeny, Transcription patterns, Gene structure, Conserved motifs...

  7. In-vitro experimental evaluation of skin-to-surface recovery of four bacterial species by antibacterial and non-antibacterial medical examination gloves.

    Science.gov (United States)

    Leitgeb, Johannes; Schuster, Rupert; Eng, Aik-Hwee; Yee, Bit-New; Teh, Yee-Peng; Dosch, Verena; Assadian, Ojan

    2013-10-11

    The number of bacteria recovered from a stainless steel coupon after touching a pigskin substrate with an examination glove coated on its outside with polyhexanide (PHMB), as compared to the number of bacteria recovered in the same manner with non-coated control gloves was evaluated. Suspensions containing 1 × 109 colony-forming units of 4 clinically relevant bacterial species (Enterococcus faecium ATCC #51559; Escherichia coli ATCC #25922; Klebsiella pneumoniae ATCC #4352; and Staphylococcus aureus ATCC #33591) were used to contaminate Gamma-irradiated pigskin substrates. Bacterial recoveries from the pigskin substrate, stainless steel coupons, and each glove swatch were performed. A difference in the bacterial recovery from the stainless steel coupons after touching with coated and uncoated control gloves was measured. For E. faecium, the coated glove showed a reduction of 4.63 log10 cfu recovery, when compared to control gloves. For E. coli, the coated glove showed 5.48 log10 cfu, for K. pneumoniae 5.03 log10 cfu, and for S. aureus 5.72 log10 cfu recovery, when compared to the non-coated control glove. An in-vitro experiment designed to mimic cross-contamination of clinically relevant bacteria in a simulated healthcare setting following glove contact with a contaminated biological surface and cross-transfer to a stainless steel surface has demonstrated that an examination glove coated on its outside surface with PHMB was able to reduce bacterial recovery from a contaminated surface by > 4 log10 cfu, compared to a control non-coated examination glove. These elaborated results may encourage further clinical investigation on the clinical impact of an antibacterial examination glove.

  8. A new penetration test method: protection efficiency of glove and clothing materials against diphenylmethane diisocyanate (MDI).

    Science.gov (United States)

    Henriks-Eckerman, Maj-Len; Mäkelä, Erja

    2015-03-01

    Reported cases of allergic contact dermatitis caused by methylenediphenyl diisocyanate (MDI) have increased and thereby increased the need for adequate skin protection. Current standardized permeation and penetration test methods give information about efficacy of protective materials against individual components of the polyurethane systems. They do not give information of what kind of clothing materials workers should wear against splashes when handling mixed MDI-polyurethane formulations, which contain MDI, its oligomers, and polyols. The aim of this study was to develop and validate a sensitive penetration test method that can be used to select clothing that is protective enough against uncured splashes of MDI-polyurethane, still easy to use, and also, to find affordable glove materials that provide adequate protection during a short contact. The penetration of MDI through eight representative glove or clothing materials was studied with the developed test procedure. One MDI hardener and two polymeric MDI (PMDI)-polyol formulations representing different curing times were used as test substances. The materials tested included work clothing (woven) fabric, arm shields (nonwoven fabric), old T-shirt, winter gloves, and gloves of nitrile rubber, leather, vinyl (PVC), and natural rubber. A drop (50 µl) of test substance was added to the outer surface of the glove/clothing material, which had Tape Fixomull attached to the inner surface as a collection medium. After penetration times of 5 or 20min, the collecting material was removed and immediately immersed into acetonitrile containing 1-(2-methoxyphenyl)-piperazine for derivatization. The formed urea derivatives of 2,4'-MDI and 4,4'-MDI were analysed using liquid chromatography with mass spectrometric and UV detection. The precision of the test method was good for the material with high penetration (work clothing fabric) of MDI, as the relative standard deviation (RSD) was 14 and 20%. For the arm shield with a low

  9. Design and evaluation of a low-cost instrumented glove for hand function assessment.

    Science.gov (United States)

    Oess, Ninja P; Wanek, Johann; Curt, Armin

    2012-01-17

    The evaluation of hand function impairment following a neurological disorder (stroke and cervical spinal cord injury) requires sensitive, reliable and clinically meaningful assessment tools. Clinical performance measures of hand function mainly focus on the accomplishment of activities of daily living (ADL), typically rather complex tasks assessed by a gross ordinal rating; while the motor performance (i.e. kinematics) is less detailed. The goal of this study was to develop a low-cost instrumented glove to capture details in grasping, feasible for the assessment of hand function in clinical practice and rehabilitation settings. Different sensor types were tested for output signal stability over time by measuring the signal drift of their step responses. A system that converted sensor output voltages into angles based on pre-measured curves was implemented. Furthermore, the voltage supply of each sensor signal conditioning circuit was increased to enhance the sensor resolution. The repeatability of finger bending trajectories, recorded during the performance of three ADL-based tasks, was established using the intraclass correlation coefficient (ICC). Moreover, the accuracy of the glove was evaluated by determining the agreement between angles measured with the embedded sensors and angles measured by traditional goniometry. In addition, the feasibility of the glove was tested in four patients with a pathological hand function caused by a cervical spinal cord injury (cSCI). A sensor type that displayed a stable output signal over time was identified, and a high sensor resolution of 0.5° was obtained. The evaluation of the glove's reliability yielded high ICC values (0.84 to 0.92) with an accuracy error of about ± 5°. Feasibility testing revealed that the glove was sensitive to distinguish different levels of hand function impairment in cSCI patients. The device satisfied the desired system requirements in terms of low cost, stable sensor signal over time, full

  10. Design and evaluation of a low-cost instrumented glove for hand function assessment

    Directory of Open Access Journals (Sweden)

    Oess Ninja P

    2012-01-01

    Full Text Available Abstract Background The evaluation of hand function impairment following a neurological disorder (stroke and cervical spinal cord injury requires sensitive, reliable and clinically meaningful assessment tools. Clinical performance measures of hand function mainly focus on the accomplishment of activities of daily living (ADL, typically rather complex tasks assessed by a gross ordinal rating; while the motor performance (i.e. kinematics is less detailed. The goal of this study was to develop a low-cost instrumented glove to capture details in grasping, feasible for the assessment of hand function in clinical practice and rehabilitation settings. Methods Different sensor types were tested for output signal stability over time by measuring the signal drift of their step responses. A system that converted sensor output voltages into angles based on pre-measured curves was implemented. Furthermore, the voltage supply of each sensor signal conditioning circuit was increased to enhance the sensor resolution. The repeatability of finger bending trajectories, recorded during the performance of three ADL-based tasks, was established using the intraclass correlation coefficient (ICC. Moreover, the accuracy of the glove was evaluated by determining the agreement between angles measured with the embedded sensors and angles measured by traditional goniometry. In addition, the feasibility of the glove was tested in four patients with a pathological hand function caused by a cervical spinal cord injury (cSCI. Results A sensor type that displayed a stable output signal over time was identified, and a high sensor resolution of 0.5° was obtained. The evaluation of the glove's reliability yielded high ICC values (0.84 to 0.92 with an accuracy error of about ± 5°. Feasibility testing revealed that the glove was sensitive to distinguish different levels of hand function impairment in cSCI patients. Conclusions The device satisfied the desired system requirements

  11. Opening up a Colourful Cosmic Jewel Box

    Science.gov (United States)

    2009-10-01

    The combination of images taken by three exceptional telescopes, the ESO Very Large Telescope on Cerro Paranal , the MPG/ESO 2.2-metre telescope at ESO's La Silla observatory and the NASA/ESA Hubble Space Telescope, has allowed the stunning Jewel Box star cluster to be seen in a whole new light. Star clusters are among the most visually alluring and astrophysically fascinating objects in the sky. One of the most spectacular nestles deep in the southern skies near the Southern Cross in the constellation of Crux. The Kappa Crucis Cluster, also known as NGC 4755 or simply the "Jewel Box" is just bright enough to be seen with the unaided eye. It was given its nickname by the English astronomer John Herschel in the 1830s because the striking colour contrasts of its pale blue and orange stars seen through a telescope reminded Herschel of a piece of exotic jewellery. Open clusters [1] such as NGC 4755 typically contain anything from a few to thousands of stars that are loosely bound together by gravity. Because the stars all formed together from the same cloud of gas and dust their ages and chemical makeup are similar, which makes them ideal laboratories for studying how stars evolve. The position of the cluster amongst the rich star fields and dust clouds of the southern Milky Way is shown in the very wide field view generated from the Digitized Sky Survey 2 data. This image also includes one of the stars of the Southern Cross as well as part of the huge dark cloud of the Coal Sack [2]. A new image taken with the Wide Field Imager (WFI) on the MPG/ESO 2.2-metre telescope at ESO's La Silla Observatory in Chile shows the cluster and its rich surroundings in all their multicoloured glory. The large field of view of the WFI shows a vast number of stars. Many are located behind the dusty clouds of the Milky Way and therefore appear red [3]. The FORS1 instrument on the ESO Very Large Telescope (VLT) allows a much closer look at the cluster itself. The telescope's huge mirror

  12. Biochemistry Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Biochemistry Facility provides expert services and consultation in biochemical enzyme assays and protein purification. The facility currently features 1) Liquid...

  13. Permeability of gloves used in nuclear medicine departments to [(99m)Tc]-pertechnetate and [(18)F]-fluorodeoxyglucose: radiation protection considerations.

    Science.gov (United States)

    Ridone, S; Matheoud, R; Valzano, S; Di Martino, R; Vigna, L; Brambilla, M

    2013-09-01

    In order to evaluate the safety of the individual protection devices, the permeability of four different types of disposable gloves, commonly used in hospitals, was tested in relation to [(99m)Tc]-pertechnetate and to [(18)F]-fluorodeoxyglucose ([(18)F]-FDG). From these radiopharmaceutical solutions, a drop was deposited on the external surface of the glove which was opened and stretched with the external surface placed upward. The smear test technique permitted to evaluate the activity onto the inner surface of the glove at different times. The smear tests were measured in a well sodium iodide detector calibrated in efficiency for (99m)Tc and (18)F. The permeability was tested on ten samples of each type of gloves and was expressed as the ratio of the activity onto the inner surface at each time interval to the activity deposited on the external surface of the glove. For each type of gloves and for each sampling time, mean value, standard deviation and percentage coefficient of variation of permeability were evaluated. One type of gloves showed a low resistance to permeation of both radiopharmaceuticals, while another one only to pertechnetate. The other gloves were good performers. The results of this study suggest to test permeability for gloves used for handling radiopharmaceuticals, before their adoption in the clinical routine. This practice will provide a more careful service of radiation protection for nuclear medicine department staff. Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  14. Packing a cake into a box

    KAUST Repository

    Skopenkov, Mikhail

    2011-05-01

    Given a triangular cake and a box in the shape of its mirror image, how can the cake be cut into a minimal number of pieces so that it can be put into the box? The cake has icing, so we are not allowed to put it into the box upside down. V. G. Boltyansky asked this question in 1977 and showed that three pieces always suffice. In this paper we provide examples of cakes that cannot be cut into two pieces to be put into the box. This shows that three is the answer to Boltyansky\\'s question. We also give examples of cakes which can be cut into two pieces. © THE MATHEMATICAL ASSOCIATION OF AMERICA.

  15. Spacer for supporting fuel element boxes

    International Nuclear Information System (INIS)

    Wild, E.

    1979-01-01

    A spacer plate unit arranged externally on each side and at a predetermined level of a polygonal fuel element box for mutually supporting, with respect to one another, a plurality of the fuel element boxes forming a fuel element bundle, is formed of a first and a second spacer plate part each having the same length and the same width and being constituted of unlike first and second materials, respectively. The first and second spacer plate parts of the several spacer plate units situated at the predetermined level are arranged in an alternating continuous series when viewed in the peripheral direction of the fuel element box, so that any two spacer plate units belonging to face-to-face oriented sides of two adjoining fuel element boxes in the fuel element bundle define interfaces of unlike materials

  16. Cosmetic Foot Surgery: Fashion's Pandora's Box

    Science.gov (United States)

    ... A A A | Print | Share Cosmetic Foot Surgery: Fashion’s Pandora’s Box? Foot and ankle surgeons warn against ... a "face lift" and fit them into high-fashion shoes. But physician members of the American College ...

  17. Black-Box Search by Unbiased Variation

    DEFF Research Database (Denmark)

    Lehre, Per Kristian; Witt, Carsten

    2012-01-01

    The complexity theory for black-box algorithms, introduced by Droste, Jansen, and Wegener (Theory Comput. Syst. 39:525–544, 2006), describes common limits on the efficiency of a broad class of randomised search heuristics. There is an obvious trade-off between the generality of the black-box model...... and the strength of the bounds that can be proven in such a model. In particular, the original black-box model provides for well-known benchmark problems relatively small lower bounds, which seem unrealistic in certain cases and are typically not met by popular search heuristics.In this paper, we introduce a more...... restricted black-box model for optimisation of pseudo-Boolean functions which we claim captures the working principles of many randomised search heuristics including simulated annealing, evolutionary algorithms, randomised local search, and others. The key concept worked out is an unbiased variation operator...

  18. ENERGY STAR Certified Set Top Boxes

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 5.1 ENERGY STAR Program Requirements for Set-top Boxes that are effective as of January...

  19. A Lithium Vapor Box Divertor Similarity Experiment

    Science.gov (United States)

    Cohen, Robert A.; Emdee, Eric D.; Goldston, Robert J.; Jaworski, Michael A.; Schwartz, Jacob A.

    2017-10-01

    A lithium vapor box divertor offers an alternate means of managing the extreme power density of divertor plasmas by leveraging gaseous lithium to volumetrically extract power. The vapor box divertor is a baffled slot with liquid lithium coated walls held at temperatures which increase toward the divertor floor. The resulting vapor pressure differential drives gaseous lithium from hotter chambers into cooler ones, where the lithium condenses and returns. A similarity experiment was devised to investigate the advantages offered by a vapor box divertor design. We discuss the design, construction, and early findings of the vapor box divertor experiment including vapor can construction, power transfer calculations, joint integrity tests, and thermocouple data logging. Heat redistribution of an incident plasma-based heat flux from a typical linear plasma device is also presented. This work supported by DOE Contract No. DE-AC02-09CH11466 and The Princeton Environmental Institute.

  20. Weld Residual Stress in Corner Boxing Joints

    OpenAIRE

    Kazuyoshi, Matsuoka; Tokuharu, Yoshii; Ship Research Institute, Ministry of Transport; Ship Research Institute, Ministry of Transport

    1998-01-01

    Fatigue damage often occurs in corner boxing welded joints because of stress concentration and residual stress. The hot spot stress approach is applicable to stress concentration. However, the number of suitable methods for estimating residual stress in welded joints is limited. The purpose of this paper is to clarify the residual stress in corner boxing joints. The method of estimating residual stresses based on the inherent stress technique is presented. Residual stress measurements are per...