WorldWideScience

Sample records for global quality control

  1. Integrated and global pseudotargeted metabolomics strategy applied to screening for quality control markers of Citrus TCMs.

    Shu, Yisong; Liu, Zhenli; Zhao, Siyu; Song, Zhiqian; He, Dan; Wang, Menglei; Zeng, Honglian; Lu, Cheng; Lu, Aiping; Liu, Yuanyan

    2017-08-01

    Traditional Chinese medicine (TCM) exerts its therapeutic effect in a holistic fashion with the synergistic function of multiple characteristic constituents. The holism philosophy of TCM is coincident with global and systematic theories of metabolomics. The proposed pseudotargeted metabolomics methodologies were employed for the establishment of reliable quality control markers for use in the screening strategy of TCMs. Pseudotargeted metabolomics integrates the advantages of both targeted and untargeted methods. In the present study, targeted metabolomics equipped with the gold standard RRLC-QqQ-MS method was employed for in vivo quantitative plasma pharmacochemistry study of characteristic prototypic constituents. Meanwhile, untargeted metabolomics using UHPLC-QE Orbitrap HRMS with better specificity and selectivity was employed for identification of untargeted metabolites in the complex plasma matrix. In all, 32 prototypic metabolites were quantitatively determined, and 66 biotransformed metabolites were convincingly identified after being orally administered with standard extracts of four labeled Citrus TCMs. The global absorption and metabolism process of complex TCMs was depicted in a systematic manner.

  2. A web service for controlling the quality of measurements of global solar irradiation

    Geiger, M.; Menard, L.; Wald, L. [Ecole des Mines, Paris (France). Centre d' Energetique; Diabate, L. [UFAE/GCMI, Bamako (Mali)

    2002-12-01

    The control of the quality of irradiation data is often a prerequisite to their further processing. Though data are usually controlled by meteorological offices, the sources are so numerous that the user often faces time-series of measurements containing questionable values. As customers of irradiation data, we established our own procedures to screen time-series of measurements. Since this problem of quality control is of concern to many researchers and engineers and since it is often a lengthy and tedious task, we decided to make this screening procedure available to everyone as a web service. This service is the purpose of this paper. The objective is not to perform a precise and fine control, an objective out of reach without details on the site and instruments, but to perform a likelihood control of the data and to check their plausibility. This is achieved by comparing observations with some expectations based upon the extraterrestrial irradiation and a simulation of the irradiation for clear skies. This service is available to everyone on the Web site www.helioclim.net. It offers a very convenient means to check time-series of irradiation: data are input in a HTML page by a copy and paste procedure and the return is also a HTML page that can be analyzed in detail for the data flagged as suspicious. (author)

  3. The Global Streamflow Indices and Metadata Archive (GSIM – Part 2: Quality control, time-series indices and homogeneity assessment

    L. Gudmundsson

    2018-04-01

    Full Text Available This is Part 2 of a two-paper series presenting the Global Streamflow Indices and Metadata Archive (GSIM, which is a collection of daily streamflow observations at more than 30 000 stations around the world. While Part 1 (Do et al., 2018a describes the data collection process as well as the generation of auxiliary catchment data (e.g. catchment boundary, land cover, mean climate, Part 2 introduces a set of quality controlled time-series indices representing (i the water balance, (ii the seasonal cycle, (iii low flows and (iv floods. To this end we first consider the quality of individual daily records using a combination of quality flags from data providers and automated screening methods. Subsequently, streamflow time-series indices are computed for yearly, seasonal and monthly resolution. The paper provides a generalized assessment of the homogeneity of all generated streamflow time-series indices, which can be used to select time series that are suitable for a specific task. The newly generated global set of streamflow time-series indices is made freely available with an digital object identifier at https://doi.pangaea.de/10.1594/PANGAEA.887470 and is expected to foster global freshwater research, by acting as a ground truth for model validation or as a basis for assessing the role of human impacts on the terrestrial water cycle. It is hoped that a renewed interest in streamflow data at the global scale will foster efforts in the systematic assessment of data quality and provide momentum to overcome administrative barriers that lead to inconsistencies in global collections of relevant hydrological observations.

  4. The Global Streamflow Indices and Metadata Archive (GSIM) - Part 2: Quality control, time-series indices and homogeneity assessment

    Gudmundsson, Lukas; Do, Hong Xuan; Leonard, Michael; Westra, Seth

    2018-04-01

    This is Part 2 of a two-paper series presenting the Global Streamflow Indices and Metadata Archive (GSIM), which is a collection of daily streamflow observations at more than 30 000 stations around the world. While Part 1 (Do et al., 2018a) describes the data collection process as well as the generation of auxiliary catchment data (e.g. catchment boundary, land cover, mean climate), Part 2 introduces a set of quality controlled time-series indices representing (i) the water balance, (ii) the seasonal cycle, (iii) low flows and (iv) floods. To this end we first consider the quality of individual daily records using a combination of quality flags from data providers and automated screening methods. Subsequently, streamflow time-series indices are computed for yearly, seasonal and monthly resolution. The paper provides a generalized assessment of the homogeneity of all generated streamflow time-series indices, which can be used to select time series that are suitable for a specific task. The newly generated global set of streamflow time-series indices is made freely available with an digital object identifier at https://doi.pangaea.de/10.1594/PANGAEA.887470" target="_blank">https://doi.pangaea.de/10.1594/PANGAEA.887470 and is expected to foster global freshwater research, by acting as a ground truth for model validation or as a basis for assessing the role of human impacts on the terrestrial water cycle. It is hoped that a renewed interest in streamflow data at the global scale will foster efforts in the systematic assessment of data quality and provide momentum to overcome administrative barriers that lead to inconsistencies in global collections of relevant hydrological observations.

  5. Global marketing control

    John Rance; Galina Zhiltsova

    2009-01-01

    The reasoning issue of this work is to research and define the efficient methods of global marketing control. The report is focused on the following aspects: the importance of the control systems in global marketing environment, the relationship between planning and controlling, types and the

  6. quality control

    Skujina, A.; Purina, S.; Riekstina, D.

    1999-01-01

    The optimal objects: soils, spruce needles and bracken ferns were found for the environmental monitoring in the regions of possible radioactive contamination - near SalaspiIs nuclear reactor and Ignalina nuclear power plant. The determination of Sr-90 was based on the radiochemical separation of Sr-90 (=Y-90) by HDEHP extraction and counting the Cerenkov radiation. The quality control of the results was carried out. (authors)

  7. Global Air Quality and Climate

    Fiore, Arlene M.; Naik, Vaishali; Steiner, Allison; Unger, Nadine; Bergmann, Dan; Prather, Michael; Righi, Mattia; Rumbold, Steven T.; Shindell, Drew T.; Skeie, Ragnhild B.; hide

    2012-01-01

    Emissions of air pollutants and their precursors determine regional air quality and can alter climate. Climate change can perturb the long-range transport, chemical processing, and local meteorology that influence air pollution. We review the implications of projected changes in methane (CH4), ozone precursors (O3), and aerosols for climate (expressed in terms of the radiative forcing metric or changes in global surface temperature) and hemispheric-to-continental scale air quality. Reducing the O3 precursor CH4 would slow near-term warming by decreasing both CH4 and tropospheric O3. Uncertainty remains as to the net climate forcing from anthropogenic nitrogen oxide (NOx) emissions, which increase tropospheric O3 (warming) but also increase aerosols and decrease CH4 (both cooling). Anthropogenic emissions of carbon monoxide (CO) and non-CH4 volatile organic compounds (NMVOC) warm by increasing both O3 and CH4. Radiative impacts from secondary organic aerosols (SOA) are poorly understood. Black carbon emission controls, by reducing the absorption of sunlight in the atmosphere and on snow and ice, have the potential to slow near-term warming, but uncertainties in coincident emissions of reflective (cooling) aerosols and poorly constrained cloud indirect effects confound robust estimates of net climate impacts. Reducing sulfate and nitrate aerosols would improve air quality and lessen interference with the hydrologic cycle, but lead to warming. A holistic and balanced view is thus needed to assess how air pollution controls influence climate; a first step towards this goal involves estimating net climate impacts from individual emission sectors. Modeling and observational analyses suggest a warming climate degrades air quality (increasing surface O3 and particulate matter) in many populated regions, including during pollution episodes. Prior Intergovernmental Panel on Climate Change (IPCC) scenarios (SRES) allowed unconstrained growth, whereas the Representative

  8. Quality-controlled sea surface temperature, salinity and other measurements from the NCEI Global Thermosalinographs Database (NCEI-TSG)

    National Oceanic and Atmospheric Administration, Department of Commerce — This collection contains global in-situ sea surface temperature (SST), salinity (SSS) and other measurements from the NOAA NCEI Global Thermosalinographs Database...

  9. SPECT quality control tests

    Robilotta, C.C.; Rebelo, M.F.S.; Oliveira, M.A.; Abe, R.

    1987-01-01

    Quality control tests of tomographic system composed by a rotatory chamber (CGR Gammatomome T-9000) and a microcomputer are presented. Traditional quality control tests for scintilation chambers and specific tests for tomographic systems are reported. (M.A.C.) [pt

  10. Global nuclear material control model

    Dreicer, J.S.; Rutherford, D.A.

    1996-01-01

    The nuclear danger can be reduced by a system for global management, protection, control, and accounting as part of a disposition program for special nuclear materials. The development of an international fissile material management and control regime requires conceptual research supported by an analytical and modeling tool that treats the nuclear fuel cycle as a complete system. Such a tool must represent the fundamental data, information, and capabilities of the fuel cycle including an assessment of the global distribution of military and civilian fissile material inventories, a representation of the proliferation pertinent physical processes, and a framework supportive of national or international perspective. They have developed a prototype global nuclear material management and control systems analysis capability, the Global Nuclear Material Control (GNMC) model. The GNMC model establishes the framework for evaluating the global production, disposition, and safeguards and security requirements for fissile nuclear material

  11. Quality assurance and quality control

    Kaden, W.

    1986-01-01

    General preconditions and methods for QA work in the nuclear field are analysed. The application of general QA principles to actual situations is illustrated by examples in the fields of engineering and of the manufacturing of mechanical and electrical components. All QA measures must be fitted to the complexity and relevance of the work steps, which are under consideration. The key to good product quality is the control of working processes. The term 'controlled process' is discussed in detail and examples of feed back systems are given. The main QA measures for the operation of nuclear power plants include the establishment of a Quality Assurance Program, training and qualification of personnel, procurement control, inspection and tests, reviews and audits. These activities are discussed. (orig.)

  12. Quality assurance and quality control

    Anon.

    1987-01-01

    The practice of nuclear diagnostic imaging requires an appropriate quality assurance program to attain high standards of efficiency and reliability. The International Atomic Energy Agency defines the term quality assurance as ''the closeness with which the outcome of a given procedure approaches some ideal, free from all errors and artifacts.'' The term quality control is used in reference to the specific measures taken to ensure that one particular aspect of the procedure is satisfactory. Therefore, quality assurance is a hospital-wide concept that should involve all aspects of clinical practice. Quality control is concerned with the submission of requests for procedures; the scheduling of patients; the preparation and dispensing of radiopharmaceuticals; the protection of patients, staff, and the general public against radiation hazards and accidents caused by radioactive materials or by faulty equipment; the setting up, use, and maintenance of electronic instruments; the methodology of the actual procedures; the analysis and interpretation of data; the reporting of results; and, finally, the keeping of records. The chapter discusses each of these areas

  13. Quality control in radiotherapy

    Batalla, A.

    2009-01-01

    The authors discuss the modalities and periodicities of internal quality control on radiotherapy installations. They indicate the different concerned systems and the aspects and items to be controlled (patient and personnel security, apparatus mechanical characteristics, beam quality, image quality, isodose and irradiation duration calculation, data transfer). They present the measurement instruments and tools used for the mechanical controls, dose measurement, beam homogeneity and symmetry, anatomic data acquisition systems, and dose distribution and control imagery calculation

  14. Quality Control Applications

    Chorafas, Dimitris N

    2013-01-01

    Quality control is a constant priority in electrical, mechanical, aeronautical, and nuclear engineering – as well as in the vast domain of electronics, from home appliances to computers and telecommunications. Quality Control Applications provides guidance and valuable insight into quality control policies; their methods, their implementation, constant observation and associated technical audits. What has previously been a mostly mathematical topic is translated here for engineers concerned with the practical implementation of quality control. Once the fundamentals of quality control are established, Quality Control Applications goes on to develop this knowledge and explain how to apply it in the most effective way. Techniques are described and supported using relevant, real-life, case studies to provide detail and clarity for those without a mathematical background. Among the many practical examples, two case studies dramatize the importance of quality assurance: A shot-by-shot analysis of the errors made ...

  15. HadISD: a quality-controlled global synoptic report database for selected variables at long-term stations from 1973–2011

    D. E. Parker

    2012-10-01

    Full Text Available This paper describes the creation of HadISD: an automatically quality-controlled synoptic resolution dataset of temperature, dewpoint temperature, sea-level pressure, wind speed, wind direction and cloud cover from global weather stations for 1973–2011. The full dataset consists of over 6000 stations, with 3427 long-term stations deemed to have sufficient sampling and quality for climate applications requiring sub-daily resolution. As with other surface datasets, coverage is heavily skewed towards Northern Hemisphere mid-latitudes. The dataset is constructed from a large pre-existing ASCII flatfile data bank that represents over a decade of substantial effort at data retrieval, reformatting and provision. These raw data have had varying levels of quality control applied to them by individual data providers. The work proceeded in several steps: merging stations with multiple reporting identifiers; reformatting to netCDF; quality control; and then filtering to form a final dataset. Particular attention has been paid to maintaining true extreme values where possible within an automated, objective process. Detailed validation has been performed on a subset of global stations and also on UK data using known extreme events to help finalise the QC tests. Further validation was performed on a selection of extreme events world-wide (Hurricane Katrina in 2005, the cold snap in Alaska in 1989 and heat waves in SE Australia in 2009. Some very initial analyses are performed to illustrate some of the types of problems to which the final data could be applied. Although the filtering has removed the poorest station records, no attempt has been made to homogenise the data thus far, due to the complexity of retaining the true distribution of high-resolution data when applying adjustments. Hence non-climatic, time-varying errors may still exist in many of the individual station records and care is needed in inferring long-term trends from these data. This

  16. Software product quality control

    Wagner, Stefan

    2013-01-01

    Quality is not a fixed or universal property of software; it depends on the context and goals of its stakeholders. Hence, when you want to develop a high-quality software system, the first step must be a clear and precise specification of quality. Yet even if you get it right and complete, you can be sure that it will become invalid over time. So the only solution is continuous quality control: the steady and explicit evaluation of a product's properties with respect to its updated quality goals.This book guides you in setting up and running continuous quality control in your environment. Star

  17. Global Controllability of Chemical Reactions

    Drexler, Dániel András; Tóth, János

    2015-01-01

    Controllability of chemical reactions is an important problem in chemical engineering science. In control theory, analysis of the controllability of linear systems is well-founded, however the dynamics of chemical reactions is usually nonlinear. Global controllability properties of chemical reactions are analyzed here based on the Lie-algebra of the vector fields associated to elementary reactions. A chemical reaction is controllable almost everywhere if all the reaction rate coefficients can...

  18. Modern science for better quality control of medicinal products "Towards global harmonization of 3Rs in biologicals": The report of an EPAA workshop.

    Schutte, Katrin; Szczepanska, Anna; Halder, Marlies; Cussler, Klaus; Sauer, Ursula G; Stirling, Catrina; Uhlrich, Sylvie; Wilk-Zasadna, Iwona; John, David; Bopst, Martin; Garbe, Joerg; Glansbeek, Harrie L; Levis, Robin; Serreyn, Pieter-Jan; Smith, Dean; Stickings, Paul

    2017-07-01

    This article summarizes the outcome of an international workshop organized by the European Partnership for Alternative Approaches to Animal Testing (EPAA) on Modern science for better quality control of medicinal products: Towards global harmonization of 3Rs in biologicals. As regards the safety testing of biologicals, the workshop participants agreed to actively encourage the deletion of abnormal toxicity tests and target animal batch safety tests from all relevant legal requirements and guidance documents (country-specific guidelines, pharmacopoeia monographs, WHO recommendations). To facilitate the global regulatory acceptance of non-animal methods for the potency testing of, e.g., human diphtheria and tetanus vaccines and veterinary swine erysipelas vaccines, international convergence on the scientific principles of the use of appropriately validated in vitro assays for replacing in vivo methods was identified as an overarching goal. The establishment of scientific requirements for new assays was recognized as a further means to unify regulatory approaches in different jurisdictions. It was recommended to include key regulators and manufacturers early in the corresponding discussions. Manufacturers and responsible expert groups, e.g. at the European Directorate for the Quality of Medicines and Health Care of the Council of Europe or the European Medicines Agency, were invited to consider leadership for international collaboration. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  19. Checking quality control?

    Brodersen, Lars

    2005-01-01

    How is quality control doing within the community of GIS, web-services based on geo-information, GI etc.?......How is quality control doing within the community of GIS, web-services based on geo-information, GI etc.?...

  20. Quality improvement and emerging global health priorities

    Mensah Abrampah, Nana; Syed, Shamsuzzoha Babar; Hirschhorn, Lisa R; Nambiar, Bejoy; Iqbal, Usman; Garcia-Elorrio, Ezequiel; Chattu, Vijay Kumar; Devnani, Mahesh; Kelley, Edward

    2018-01-01

    Abstract Quality improvement approaches can strengthen action on a range of global health priorities. Quality improvement efforts are uniquely placed to reorient care delivery systems towards integrated people-centred health services and strengthen health systems to achieve Universal Health Coverage (UHC). This article makes the case for addressing shortfalls of previous agendas by articulating the critical role of quality improvement in the Sustainable Development Goal era. Quality improvement can stimulate convergence between health security and health systems; address global health security priorities through participatory quality improvement approaches; and improve health outcomes at all levels of the health system. Entry points for action include the linkage with antimicrobial resistance and the contentious issue of the health of migrants. The work required includes focussed attention on the continuum of national quality policy formulation, implementation and learning; alongside strengthening the measurement-improvement linkage. Quality improvement plays a key role in strengthening health systems to achieve UHC. PMID:29873793

  1. Quality control of radiopharmaceuticals

    Verdera, E.S.

    1994-01-01

    The quality control of radiopharmaceuticals is based in physics, physics-chemical and biological controls. Between the different controls can be enumerated the following: visual aspect,side, number of particle beams,activity,purity,ph,isotonicity,sterility,radioinmunoessay,toxicity,stability and clinical essay

  2. Quality Control in construction.

    1984-01-01

    behavioral scientists. In 1962, Dr. Kaoru Ishikawa gave shape to the form of training which featured intradepartmental groups of ten or so workers seated...and Japanese circles bears closer scrutiny. 4.3.1 Japanese Ingredients of Quality The founder of quality circles, Dr. Kaoru Ishikawa , gives six...around 51 a table; hence the name Quality Control Circle. 4 Dr. 0 Ishikawa was an engineering professor at Tokyo University, and the circles were

  3. Global Air Quality and Health Co-benefits of Mitigating Near-term Climate Change Through Methane and Black Carbon Emission Controls

    Anenberg, Susan C.; Schwartz, Joel; Shindell, Drew Todd; Amann, Markus; Faluvegi, Gregory S.; Klimont, Zbigniew; Janssens-Maenhout, Greet; Pozzoli, Luca; Dingenen, Rita Van; Vignati, Elisabetta; hide

    2012-01-01

    Tropospheric ozone and black carbon (BC), a component of fine particulate matter (PM health benefits of 14 specific emission control measures targeting BC and methane, an ozone precursor, that were selected because of their potential to reduce the rate of climate change over the next 20-40 years. Methods: We simulated the impacts of mitigation measures on outdoor concentrations of PM2.5 and ozone using two composition-climate models, and calculated associated changes in premature PM2.5- and ozone-related deaths using epidemiologically derived concentration-response functions. Results: We estimated that, for PM2.5 and ozone, respectively, fully implementing these measures could reduce global population-weighted average surface concentrations by 23-34% and 7-17% and avoid 0.6-4.4 and 0.04-0.52 million annual premature deaths globally in 2030. More than 80% of the health benefits are estimated to occur in Asia. We estimated that BC mitigation measures would achieve approximately 98% of the deaths that would be avoided if all BC and methane mitigation measures were implemented, due to reduced BC and associated reductions of nonmethane ozone precursor and organic carbon emissions as well as stronger mortality relationships for PM2.5 relative to ozone. Although subject to large uncertainty, these estimates and conclusions are not strongly dependent on assumptions for the concentration-response function. Conclusions: In addition to climate benefits, our findings indicate that the methane and BC emission control measures would have substantial co-benefits for air quality and public health worldwide, potentially reversing trends of increasing air pollution concentrations and mortality in Africa and South, West, and Central Asia. These projected benefits are independent of carbon dioxide mitigation measures. Benefits of BC measures are underestimated because we did not account for benefits from reduced indoor exposures and because outdoor exposure estimates were limited by

  4. Quality control of radiopharmaceuticals

    Kristensen, K.

    1981-01-01

    Quality assurance was introduced in the pharmaceutical field long before it was used in many other areas, and the term quality control has been used in a much broader sense than merely analytical quality control. The term Good Manufacturing Practice (GMP) has been used to describe the system used for producing safe and effective drugs of a uniform quality. GMP has also been used for the industrial production of radiopharmaceuticals. For the preparation and control of radiopharmaceuticals in hospitals a similar system has been named Good Radiopharmacy Practice (GRP). It contains the same elements as GMP but takes into account the special nature of this group of drugs. Data on the assessment of the quality of radiopharmaceuticals in relation to present standards are reviewed. The general conclusion is that the quality of radiopharmaceuticals appears comparable to that of other drugs. It seems possible to establish the production of radiopharmaceuticals, generators and preparation kits in such a way that analytical control of the final product at the hospital may be limited provided the final preparation work is carried out in accordance with GRP principles. The elements of GRP are reviewed. (author)

  5. Quality control of dosemeters

    Mendes, L.

    1984-01-01

    Nuclear medicine laboratories are required to assay samples of radioactivity to be administered to patients. Almost universally, these assays are acomplished by use of a well ionization chamber isotope calibrator. The Instituto de Radioprotecao e Dosimetria (Institute for Radiological Protection and Dosimetry) of the Comissao Nacional de Energia Nuclear (National Commission for Nuclear Energy) is carrying out a National Quality Control Programme in Nuclear Medicine, supported by the International Atomic Energy Agency. The assessment of the current needs and practices of quality control in the entire country of Brazil includes Dose Calibrators and Scintilation Cameras, but this manual is restricted to the former. Quality Control Procedures for these Instruments are described in this document together with specific recommendations and assessment of its accuracy. (Author) [pt

  6. Global Quality Management in Adjusting Prices

    Bunta Levente Zoltán

    2013-01-01

    The following paper describes the basic principles of global quality management (T and the way that these influence pricing in a domain where due to the nature of the provided service, the provider who administers the network has a monopoly over the field.

  7. Infectious Disinfection: "Exploring Global Water Quality"

    Mahaya, Evans; Tippins, Deborah J.; Mueller, Michael P.; Thomson, Norman

    2009-01-01

    Learning about the water situation in other regions of the world and the devastating effects of floods on drinking water helps students study science while learning about global water quality. This article provides science activities focused on developing cultural awareness and understanding how local water resources are integrally linked to the…

  8. Quality Management, Quality Assurance and Quality Control in Blood Establishments

    Bolbate, N

    2008-01-01

    Quality terms and the roots of the matter are analyzed according to European Committee’s recommendations. Essence of process and product quality control as well as essence of quality assurance is described. Quality system’s structure including quality control, quality assurance and management is justified in the article.

  9. Quality control in haemostasis.

    Capel, P; Chatelain, B; Leclerq, R; Lust, A; Masure, R; Arnout, J

    1992-01-01

    Laboratory investigation of the haemostatic system deserves particular procedures in the quality control of analytical variables as well as preanalytical variables. This paper reviews the precautions that have to be taken in the blood prelevement, the transport of the tubes and the performance of the laboratory tests aimed to investigate the haemostatic system in order to obtain reliable results.

  10. Ocean Data Quality Control

    2011-11-18

    the aero- sol at the coincident time and location of the satellite SST retrievals. This informa- tion is available in the daytime for the anti-solar...are of the same form, such as probabilities or standard normal deviates. A quality control decision-making algorithm in use at the U.S. Navy oceano

  11. VGI QUALITY CONTROL

    C. C. Fonte

    2015-08-01

    Full Text Available This paper presents a framework for considering quality control of volunteered geographic information (VGI. Different issues need to be considered during the conception, acquisition and post-acquisition phases of VGI creation. This includes items such as collecting metadata on the volunteer, providing suitable training, giving corrective feedback during the mapping process and use of control data, among others. Two examples of VGI data collection are then considered with respect to this quality control framework, i.e. VGI data collection by National Mapping Agencies and by the most recent Geo-Wiki tool, a game called Cropland Capture. Although good practices are beginning to emerge, there is still the need for the development and sharing of best practice, especially if VGI is to be integrated with authoritative map products or used for calibration and/or validation of land cover in the future.

  12. Quality control of mammography

    Hering, K.G.

    1986-01-01

    Random checks of mammograms allow to clearly assess quality controls concerning correct application and operation of the radiographic system indicated by rich contrast in breast tissue images, complete imaging of the mammary parenchyma, freedom from blurs due to motion, efficient breast compression, correct film labelling and perfect maintenance of the film screen system. In addition to these subjective assessments, the following points should be considered when using objective measurement procedures and phantoms: Testing the correct function of X-ray and radiographic equipment by means of test specimens to measure KV standard (KV=Association of German Panel Doctors), mAS and automatic exposure timer; comparing dose and density to initial values and checking film processing by using a sensitometer. Quality assurance handling varies from one KV to the next. That is why the users need to obtain the guidelines of the respective KV relative to radiological quality assurance and to proceed according to these. (orig.) [de

  13. Quality control of intelligence research

    Lu Yan; Xin Pingping; Wu Jian

    2014-01-01

    Quality control of intelligence research is the core issue of intelligence management, is a problem in study of information science This paper focuses on the performance of intelligence to explain the significance of intelligence research quality control. In summing up the results of the study on the basis of the analysis, discusses quality control methods in intelligence research, introduces the experience of foreign intelligence research quality control, proposes some recommendations to improve quality control in intelligence research. (authors)

  14. Organizing quality control programmes

    Hjardemaal, O.

    1989-01-01

    When procuring new equipment, performance and safety should be specified, if possible by reference to international standards. Some of the characteristics of the International Electrotechnical Commission (IEC) standard for X-ray generators, in particular the accuracy of the operating data, are described. The quality control tests to be performed after installation comprise acceptance test, status test and constancy test. The first two involve absolute measurements and will be the responsibility of physicists or engineers. Apparently limiting values stipulated by users are a factor of two lower than the limits of the IEC standard. By means of an example it is shown that modern X-ray generators can meet the lower limits of the users without problems. In order to obtain optimum initial quality when procuring new equipment operating data, limiting values must be specified and must be verified by acceptance testing, etc. However, in many countries physicists and engineers are not available for this job. A relatively uncomplicated test object can be used by radiographers for checks on fluoroscopic systems. The findings from such tests in Denmark are compared with other published findings and good agreement is found. Therefore it is proposed that such uncomplicated tests could form the basis for quality evaluation. (author)

  15. Quality control of radiodiagnostics

    Alonso Diaz, M.; Castaneda Arronte, M.J.; Matorras Galan, P.; Diaz-Caneja Rodriguez, N.; Gutierrez Diaz Velarde, I.

    1993-01-01

    Since May 1990, a program of quality control of diagnostic X-ray equipment is underway in the University Hospital Marques de Valdecilla. This includes the design and application of measuring specifications and procedures corresponding to the different parameters of the equipment. The specified values are presented, as are those obtained for geometric and exposition parameters using the equipment. The specifications for the geometric parameters are fulfilled in an large proportion (between 52 and 86%) of the units, and the rest can easily be adjusted. However, 85% of the units can be made to operate with a field larger than that of the screen of the image monitor and approximately half of them can operate at a shorter focus-to-patient distance than that specified. With respect to the exposition parameters, in general, these units do not fulfill the specifications and their behavior is not uniform. The results obtained indicate that the equipment studied could be made to comply with the proposed specifications if a Maintenance Program were initiated in coordination with that of Quality Control. (Author)

  16. Interaction between production control and quality control

    Bij, van der J.D.; Ekert, van J.H.W.

    1999-01-01

    Describes a qualitative study on interaction between systems for production control and quality control within industrial organisations. Production control and quality control interact in a sense. Good performance for one aspect often influences or frustrates the performance of the other. As far as

  17. Quality control in nuclear medicine

    Leme, P.R.

    1983-01-01

    The following topics are discussed: objectives of the quality control in nuclear medicine; the necessity of the quality control in nuclear medicine; guidelines and recommendations. An appendix is given concerning the guidelines for the quality control and instrumentation in nuclear medicine. (M.A.) [pt

  18. Climate Change and Global Wine Quality

    Jones, G.V. [Department of Geography, Southern Oregon University, 1250 Siskiyou Blvd, Ashland, Oregon, 97520 (United States); White, M.A. [Department of Aquatic, Watershed, and Earth Resources, Utah State University, Logan, Utah, 84322 (United States); Cooper, O.R. [Cooperative Institute for Research in Environmental Sciences CIRES, University of Colorado/NOAA Aeronomy Laboratory, Boulder, Colorado, 80305 (United States); Storchmann, K. [Department of Economics, Yale University, New Haven, Connecticut, 06520 (United States)

    2005-12-01

    From 1950 to 1999 the majority of the world's highest quality wine-producing regions experienced growing season warming trends. Vintage quality ratings during this same time period increased significantly while year-to-year variation declined. While improved winemaking knowledge and husbandry practices contributed to the better vintages it was shown that climate had, and will likely always have, a significant role in quality variations. This study revealed that the impacts of climate change are not likely to be uniform across all varieties and regions. Currently, many European regions appear to be at or near their optimum growing season temperatures, while the relationships are less defined in the New World viticulture regions. For future climates, model output for global wine producing regions predicts an average warming of 2C in the next 50 yr. For regions producing high-quality grapes at the margins of their climatic limits, these results suggest that future climate change will exceed a climatic threshold such that the ripening of balanced fruit required for existing varieties and wine styles will become progressively more difficult. In other regions, historical and predicted climate changes could push some regions into more optimal climatic regimes for the production of current varietals. In addition, the warmer conditions could lead to more poleward locations potentially becoming more conducive to grape growing and wine production.

  19. Printing quality control automation

    Trapeznikova, O. V.

    2018-04-01

    One of the most important problems in the concept of standardizing the process of offset printing is the control the quality rating of printing and its automation. To solve the problem, a software has been developed taking into account the specifics of printing system components and the behavior in printing process. In order to characterize the distribution of ink layer on the printed substrate the so-called deviation of the ink layer thickness on the sheet from nominal surface is suggested. The geometric data construction the surface projections of the color gamut bodies allows to visualize the color reproduction gamut of printing systems in brightness ranges and specific color sectors, that provides a qualitative comparison of the system by the reproduction of individual colors in a varying ranges of brightness.

  20. Quality control in urinalysis.

    Takubo, T; Tatsumi, N

    1999-01-01

    Quality control (QC) has been introduced in laboratories, and QC surveys in urinalysis have been performed by College of American Pathologist, by Japanese Association of Medical Technologists, by Osaka Medical Association and by manufacturers. QC survey in urinalysis for synthetic urine by the reagent strip and instrument made in same manufacturer, and by an automated urine cell analyser provided satisfactory results among laboratories. QC survey in urinalysis for synthetic urine by the reagent strips and instruments made by various manufacturers indicated differences in the determination values among manufacturers, and between manual and automated methods because the reagent strips and instruments have different characteristics, respectively. QC photo survey in urinalysis on the microscopic photos of urine sediment constituents indicated differences in the identification of cells among laboratories. From the results, it is necessary to standardize a reagent strip method, manual and automated methods, and synthetic urine.

  1. Global Command and Control Management Structure

    1995-01-01

    This instruction establishes: responsibilities for the Joint Staff, Services, Defense agencies, combatant and functional unified commands, and other activities regarding management of Global Command and Control (GCC...

  2. Globalization and localization of Management Control Systems

    Toldbod, Thomas; Israelsen, Poul

    2014-01-01

    Through an empirical case study this article examines the operation of multiple management control systems as a package in a Danish manufacturing company. The analysis focuses on four different management control systems; cybernetic controls, planning controls, reward controls, and administrative...... have more particular characteristics. Specifically, this study finds that cybernetic controls and administrative controls are designed as global management control systems. Planning controls are glocal systems and reward & compensation controls assume local characteristics. The finding leads...... controls, through the theoretical lens of globalization, localization, and glocalization. The analysis documents that these different management control systems are affected differently by the processes of globalization and localization, whereby some are universal throughout the organization and others...

  3. The network of global corporate control.

    Vitali, Stefania; Glattfelder, James B; Battiston, Stefano

    2011-01-01

    The structure of the control network of transnational corporations affects global market competition and financial stability. So far, only small national samples were studied and there was no appropriate methodology to assess control globally. We present the first investigation of the architecture of the international ownership network, along with the computation of the control held by each global player. We find that transnational corporations form a giant bow-tie structure and that a large portion of control flows to a small tightly-knit core of financial institutions. This core can be seen as an economic "super-entity" that raises new important issues both for researchers and policy makers.

  4. Commercial jet fuel quality control

    Strauss, K.H.

    1995-05-01

    The paper discusses the purpose of jet fuel quality control between the refinery and the aircraft. It describes fixed equipment, including various types of filters, and the usefulness and limitations of this equipment. Test equipment is reviewed as are various surveillance procedures. These include the Air Transport Association specification ATA 103, the FAA Advisory Circular 150/5230-4, the International Air Transport Association Guidance Material for Fuel Quality Control and Fuelling Service and the Guidelines for Quality Control at Jointly Operated Fuel Systems. Some past and current quality control problems are briefly mentioned.

  5. The 'Alternative Quality Contract,' based on a global budget, lowered medical spending and improved quality.

    Song, Zirui; Safran, Dana Gelb; Landon, Bruce E; Landrum, Mary Beth; He, Yulei; Mechanic, Robert E; Day, Matthew P; Chernew, Michael E

    2012-08-01

    Seven provider organizations in Massachusetts entered the Blue Cross Blue Shield Alternative Quality Contract in 2009, followed by four more organizations in 2010. This contract, based on a global budget and pay-for-performance for achieving certain quality benchmarks, places providers at risk for excessive spending and rewards them for quality, similar to the new Pioneer Accountable Care Organizations in Medicare. We analyzed changes in spending and quality associated with the Alternative Quality Contract and found that the rate of increase in spending slowed compared to control groups, more so in the second year than in the first. Overall, participation in the contract over two years led to savings of 2.8 percent (1.9 percent in year 1 and 3.3 percent in year 2) compared to spending in nonparticipating groups. Savings were accounted for by lower prices achieved through shifting procedures, imaging, and tests to facilities with lower fees, as well as reduced utilization among some groups. Quality of care also improved compared to control organizations, with chronic care management, adult preventive care, and pediatric care within the contracting groups improving more in year 2 than in year 1. These results suggest that global budgets with pay-for-performance can begin to slow underlying growth in medical spending while improving quality of care.

  6. INFORMATION SYSTEM QUALITY CONTROL KNOWLEDGE

    Vladimir Nikolaevich Babeshko

    2017-02-01

    Full Text Available The development of the educational system is associated with the need to control the quality of educational services. Quality control knowledge is an important part of the scientific process. The penetration of computers into all areas of activities changing approaches and technologies that previously they were used.

  7. Frontiers in statistical quality control

    Wilrich, Peter-Theodor

    2004-01-01

    This volume treats the four main categories of Statistical Quality Control: General SQC Methodology, On-line Control including Sampling Inspection and Statistical Process Control, Off-line Control with Data Analysis and Experimental Design, and, fields related to Reliability. Experts with international reputation present their newest contributions.

  8. The ILC global control system

    Carwardine, J.; Arnold, N.; Lenkszus, F.; Saunders, C.; Rehlich, K.; Simrock, S.; Banerjee, B.; Chase, B.; Gottschalk, E.; Joireman, P.; Kasley, P.; Lackey, S.; McBride, P.; Pavlicek, V.; Patrick, J.; Votava, M.; Wolbers, S.; Furukawa, K.; Michizono, S.; Larsen, R.S.; Downing, R.

    2008-01-01

    The scale and performance parameters of the ILC require new thinking in regards to control system design. This design work has begun quite early in comparison to most accelerator projects, with the goal of uniquely high overall accelerator availability. Among the design challenges are high control system availability, precision timing and rf phase reference distribution, standardizing of interfaces, operability, and maintainability. We present the current state of the design and take a prospective look at ongoing research and development projects.

  9. Combining local and global optimisation for virtual camera control

    Burelli, Paolo; Yannakakis, Georgios N.; 2010 IEEE Symposium on Computational Intelligence and Games

    2010-01-01

    Controlling a virtual camera in 3D computer games is a complex task. The camera is required to react to dynamically changing environments and produce high quality visual results and smooth animations. This paper proposes an approach that combines local and global search to solve the virtual camera control problem. The automatic camera control problem is described and it is decomposed into sub-problems; then a hierarchical architecture that solves each sub-problem using the most appropriate op...

  10. The Global Control of the Virgo experiment

    Arnaud, Nicolas; Arnault, Christian; Barsuglia, Matteo; Bizouard, Marie-Anne; Brisson, Violette; Cavalier, Fabien; Chiche, Ronic; Davier, Michel; Eder, Claude; Hello, Patrice; Heusse, Philippe; Kreckelbergh, Stephane; Mansoux, Bruno

    2005-01-01

    In order to detect gravitational waves, the kilometric interferometer Virgo needs an active control of the positions of the suspended optical components, keeping the detector at its working point. The constraints are about 10 -10 m RMS for the longitudinal control ('Locking') and 10 -9 rad RMS for the angular degrees of freedom ('Alignment'). A dedicated hardware and software named Global Control is in charge of the Locking and the Alignment loops for the Virgo experiment. This system has been designed to match the synchronization constraint and provide a flexible tool in order to easily integrate the various algorithms needed for the control of Virgo. This paper presents the technical requirements to be fulfilled by the Global Control. Then, the dedicated hardware is described and the overall architecture of the Global Control is shown

  11. The Global Control of the Virgo experiment

    Arnaud, Nicolas [Laboratoire de l' Accelerateur Lineaire, CNRS-IN2P3 and Universite Paris Sud, Ba-hat timent 200, Campus d' Orsay, B.P. 34, 91898 Orsay Cedex (France); Arnault, Christian [Laboratoire de l' Accelerateur Lineaire, CNRS-IN2P3 and Universite Paris Sud, Ba-hat timent 200, Campus d' Orsay, B.P. 34, 91898 Orsay Cedex (France); Barsuglia, Matteo [Laboratoire de l' Accelerateur Lineaire, CNRS-IN2P3 and Universite Paris Sud, Ba-hat timent 200, Campus d' Orsay, B.P. 34, 91898 Orsay Cedex (France); Bizouard, Marie-Anne [Laboratoire de l' Accelerateur Lineaire, CNRS-IN2P3 and Universite Paris Sud, Ba-hat timent 200, Campus d' Orsay, B.P. 34, 91898 Orsay Cedex (France); Brisson, Violette [Laboratoire de l' Accelerateur Lineaire, CNRS-IN2P3 and Universite Paris Sud, Ba-hat timent 200, Campus d' Orsay, B.P. 34, 91898 Orsay Cedex (France); Cavalier, Fabien [Laboratoire de l' Accelerateur Lineaire, CNRS-IN2P3 and Universite Paris Sud, Ba-hat timent 200, Campus d' Orsay, B.P. 34, 91898 Orsay Cedex (France)]. E-mail: cavalier@lal.in2p3.fr; Chiche, Ronic [Laboratoire de l' Accelerateur Lineaire, CNRS-IN2P3 and Universite Paris Sud, Ba-hat timent 200, Campus d' Orsay, B.P. 34, 91898 Orsay Cedex (France); Davier, Michel [Laboratoire de l' Accelerateur Lineaire, CNRS-IN2P3 and Universite Paris Sud, Ba-hat timent 200, Campus d' Orsay, B.P. 34, 91898 Orsay Cedex (France); Eder, Claude [Laboratoire de l' Accelerateur Lineaire, CNRS-IN2P3 and Universite Paris Sud, Ba-hat timent 200, Campus d' Orsay, B.P. 34, 91898 Orsay Cedex (France); Hello, Patrice [Laboratoire de l' Accelerateur Lineaire, CNRS-IN2P3 and Universite Paris Sud, Ba-hat timent 200, Campus d' Orsay, B.P. 34, 91898 Orsay Cedex (France); Heusse, Philippe; Kreckelbergh, Stephane; Mansoux, Bruno [Laboratoire de l' Accelerateur Lineaire, CNRS-IN2P3 and Universite Paris Sud, Ba-hat timent 200, Campus d' Orsay, B.P. 34, 91898 Orsay Cedex (France)

    2005-09-11

    In order to detect gravitational waves, the kilometric interferometer Virgo needs an active control of the positions of the suspended optical components, keeping the detector at its working point. The constraints are about 10{sup -10}m RMS for the longitudinal control ('Locking') and 10{sup -9}rad RMS for the angular degrees of freedom ('Alignment'). A dedicated hardware and software named Global Control is in charge of the Locking and the Alignment loops for the Virgo experiment. This system has been designed to match the synchronization constraint and provide a flexible tool in order to easily integrate the various algorithms needed for the control of Virgo. This paper presents the technical requirements to be fulfilled by the Global Control. Then, the dedicated hardware is described and the overall architecture of the Global Control is shown.

  12. Quality assurance programme and quality control

    Alvarez de Buergo, L.

    1979-01-01

    The paper analyses the requirements for the quality assurance and control in nuclear power plant projects which are needed to achieve safe, reliable and economic plants. The author describes the structure for the establishment of a nuclear programme at the national level and the participation of the different bodies involved in a nuclear power plant project. The paper ends with the study of a specific case in Spain. (NEA) [fr

  13. Brand quality and internationality: Branded global chain hotels

    Vrkljan, Sanela; Bartoluci, Mato; Čižmar, Sanja

    2017-01-01

    It is increasingly testing for individual hotels, even the well-run and famous ones, to compete and grow in the wider world market without having the underpinning and benefits of the global representation. Perhaps, this is why even the more notable establishments, join hotel chains or a global hotel management conglomerate. This paper focuses on the correlation between business performance of global chain hotels (GCHs) and quality and internationality of the brand they belong to. The quality ...

  14. Network-based production quality control

    Kwon, Yongjin; Tseng, Bill; Chiou, Richard

    2007-09-01

    This study investigates the feasibility of remote quality control using a host of advanced automation equipment with Internet accessibility. Recent emphasis on product quality and reduction of waste stems from the dynamic, globalized and customer-driven market, which brings opportunities and threats to companies, depending on the response speed and production strategies. The current trends in industry also include a wide spread of distributed manufacturing systems, where design, production, and management facilities are geographically dispersed. This situation mandates not only the accessibility to remotely located production equipment for monitoring and control, but efficient means of responding to changing environment to counter process variations and diverse customer demands. To compete under such an environment, companies are striving to achieve 100%, sensor-based, automated inspection for zero-defect manufacturing. In this study, the Internet-based quality control scheme is referred to as "E-Quality for Manufacturing" or "EQM" for short. By its definition, EQM refers to a holistic approach to design and to embed efficient quality control functions in the context of network integrated manufacturing systems. Such system let designers located far away from the production facility to monitor, control and adjust the quality inspection processes as production design evolves.

  15. Quality control of radiopharmaceuticals

    Wallen, O.; Komarov, E.

    1973-01-01

    The International Pharmacopoeia published by WHO constitutes a collection of recommended specifications for pharmaceutical preparations which are not intended to have legal status in any country, but serve as references so that national specifications can be established on a similar basis in any country. Like any pharmacopoeia, it contains monographs for the quality con trol of drugs by means of chemical, physical and simple biological methods, as well as appendices describing general methods. The work on the International Pharmacopoeia is carried out by WHO with the aid of the Expert Advisory Panel on the International Pharmacopoeia and Pharmaceutical Preparations and other specialists from various countries and the Expert Committee on Specifications for Pharmaceutical Preparations. (author)

  16. Quality control of labelled compounds

    Matucha, M.

    1979-01-01

    Some advantages and disadvantages of methods used for quality control of organic labelled compounds (1 31 I, 14 C) are shortly discussed. The methods used are electrophoresis, ultraviolet and infrared spectrometry, radiogas and thin-layer chromatography. (author)

  17. [Quality control in herbal supplements].

    Oelker, Luisa

    2005-01-01

    Quality and safety of food and herbal supplements are the result of a whole of different elements as good manufacturing practice and process control. The process control must be active and able to individuate and correct all possible hazards. The main and most utilized instrument is the hazard analysis critical control point (HACCP) system the correct application of which can guarantee the safety of the product. Herbal supplements need, in addition to standard quality control, a set of checks to assure the harmlessness and safety of the plants used.

  18. Fuel cycle and quality control

    Stoll, W.

    1979-01-01

    The volume of the fuel cycle is described in its economic importance and its through put, as it is envisaged for the Federal Republic of Germany. Definitions are given for quality continuing usefulness of an object and translated into quality criteria. Requirements on performance of fuel elements are defined. The way in which experimental results are translated into mass production of fuel rods, is described. The economic potential for further quality effort is derived. Future ways of development for quality control organisation and structure are outlined. (Auth.)

  19. SAQC: SNP Array Quality Control

    Li Ling-Hui

    2011-04-01

    Full Text Available Abstract Background Genome-wide single-nucleotide polymorphism (SNP arrays containing hundreds of thousands of SNPs from the human genome have proven useful for studying important human genome questions. Data quality of SNP arrays plays a key role in the accuracy and precision of downstream data analyses. However, good indices for assessing data quality of SNP arrays have not yet been developed. Results We developed new quality indices to measure the quality of SNP arrays and/or DNA samples and investigated their statistical properties. The indices quantify a departure of estimated individual-level allele frequencies (AFs from expected frequencies via standardized distances. The proposed quality indices followed lognormal distributions in several large genomic studies that we empirically evaluated. AF reference data and quality index reference data for different SNP array platforms were established based on samples from various reference populations. Furthermore, a confidence interval method based on the underlying empirical distributions of quality indices was developed to identify poor-quality SNP arrays and/or DNA samples. Analyses of authentic biological data and simulated data show that this new method is sensitive and specific for the detection of poor-quality SNP arrays and/or DNA samples. Conclusions This study introduces new quality indices, establishes references for AFs and quality indices, and develops a detection method for poor-quality SNP arrays and/or DNA samples. We have developed a new computer program that utilizes these methods called SNP Array Quality Control (SAQC. SAQC software is written in R and R-GUI and was developed as a user-friendly tool for the visualization and evaluation of data quality of genome-wide SNP arrays. The program is available online (http://www.stat.sinica.edu.tw/hsinchou/genetics/quality/SAQC.htm.

  20. Balancing Attended and Global Stimuli in Perceived Video Quality Assessment

    You, Junyong; Korhonen, Jari; Perkis, Andrew

    2011-01-01

    . This paper proposes a quality model based on the late attention selection theory, assuming that the video quality is perceived via two mechanisms: global and local quality assessment. First we model several visual features influencing the visual attention in quality assessment scenarios to derive......The visual attention mechanism plays a key role in the human perception system and it has a significant impact on our assessment of perceived video quality. In spite of receiving less attention from the viewers, unattended stimuli can still contribute to the understanding of the visual content...... an attention map using appropriate fusion techniques. The global quality assessment as based on the assumption that viewers allocate their attention equally to the entire visual scene, is modeled by four carefully designed quality features. By employing these same quality features, the local quality model...

  1. Exploring global recognition of quality midwifery education: Vision or fiction?

    Luyben, Ans; Barger, Mary; Avery, Melissa; Bharj, Kuldip Kaur; O'Connell, Rhona; Fleming, Valerie; Thompson, Joyce; Sherratt, Della

    2017-06-01

    Midwifery education is the foundation for preparing competent midwives to provide a high standard of safe, evidence-based care for women and their newborns. Global competencies and standards for midwifery education have been defined as benchmarks for establishing quality midwifery education and practice worldwide. However, wide variations in type and nature of midwifery education programs exist. To explore and discuss the opportunities and challenges of a global quality assurance process as a strategy to promote quality midwifery education. Accreditation and recognition as two examples of quality assurance processes in education are discussed. A global recognition process, with its opportunities and challenges, is explored from the perspective of four illustrative case studies from Ireland, Kosovo, Latin America and Bangladesh. The discussion highlights that the establishment of a global recognition process may assist in promoting quality of midwifery education programs world-wide, but cannot take the place of formal national accreditation. In addition, a recognition process will not be feasible for many institutions without additional resources, such as financial support or competent evaluators. In order to achieve quality midwifery education through a global recognition process the authors present 5 Essential Challenges for Quality Midwifery Education. Quality midwifery education is vital for establishing a competent workforce, and improving maternal and newborn health. Defining a global recognition process could be instrumental in moving toward this goal, but dealing with the identified challenges will be essential. Copyright © 2017 Australian College of Midwives. Published by Elsevier Ltd. All rights reserved.

  2. Frontiers in statistical quality control

    Wilrich, Peter-Theodor

    2001-01-01

    The book is a collection of papers presented at the 5th International Workshop on Intelligent Statistical Quality Control in Würzburg, Germany. Contributions deal with methodology and successful industrial applications. They can be grouped in four catagories: Sampling Inspection, Statistical Process Control, Data Analysis and Process Capability Studies and Experimental Design.

  3. Global warming and climate change: control methods

    Laal, M.; Aliramaie, A.

    2008-01-01

    This paper aimed at finding causes of global warming and ways to bring it under control. Data based on scientific opinion as given by synthesis reports of news, articles, web sites, and books. global warming is the observed and projected increases in average temperature of Earth's atmosphere and oceans. Carbon dioxide and other air pollution that is collecting in the atmosphere like a thickening blanket, trapping the sun's heat and causing the planet to warm up. Pollution is one of the biggest man-made problems. Burning fossil fuels is the main factor of pollution. As average temperature increases, habitats, species and people are threatened by drought, changes in rainfall, altered seasons, and more violent storms and floods. Indeed the life cycle of nuclear power results in relatively little pollution. Energy efficiency, solar, wind and other renewable fuels are other weapons against global warming . Human activity, primarily burning fossil fuels, is the major driving factor in global warming . Curtailing the release of carbon dioxide into the atmosphere by reducing use of oil, gasoline, coal and employment of alternate energy, sources are the tools for keeping global warming under control. global warming can be slowed and stopped, with practical actions thal yield a cleaner, healthier atmosphere

  4. Principles and Practices for Quality Assurance and Quality Control

    Jones, Berwyn E.

    1999-01-01

    Quality assurance and quality control are vital parts of highway runoff water-quality monitoring projects. To be effective, project quality assurance must address all aspects of the project, including project management responsibilities and resources, data quality objectives, sampling and analysis plans, data-collection protocols, data quality-control plans, data-assessment procedures and requirements, and project outputs. Quality control ensures that the data quality objectives are achieved as planned. The historical development and current state of the art of quality assurance and quality control concepts described in this report can be applied to evaluation of data from prior projects.

  5. Quality Control and Quality Assurance of Radiation Oncology

    Abaza, A.

    2016-01-01

    Radiotherapy (RT) has played important roles in cancer treatment for more than one century. The development of RT techniques allows high-dose irradiation to tumors while reducing the radiation doses delivered to surrounding normal tissues. However, RT is a complex process and involves understanding of the principles of medical physics, radiobiology, radiation safety, dosimetry, radiation treatment planning, simulation and interaction of radiation with other treatment modalities. Each step in the integrated process of RT needs quality control and quality assurance (QA) to prevent errors and to ensure that patients will receive the prescribed treatment correctly. The aim of this study is to help the radio therapists in identifying a system for QA that balances patient safety and quality with available resources. Recent advances in RT focus on the need for a systematic RT QA program that balances patient safety and quality with available resources. It is necessary to develop more formal error mitigation and process analysis methods, such as failure mode and effect analysis (FMEA), to focus available QA resources optimally on the process components. External audit programs are also effective. Additionally, Clinical trial QA has a significant role in enhancing the quality of care. The International Atomic Energy Agency (IAEA) has operated both an on-site and off-site postal dosimetry audit to improve practice and to assure the dose from RT equipment. Both postal dosimetry audit and clinical trial RTQA, especially for advanced technologies, in collaboration with global networks, will serve to enhance patient safety and quality of care

  6. Quality Control - Nike.Inc

    Walter G. Bishop

    2017-01-01

    The purpose of this paper is to present the illustration of quality control approach, which has been adopted by several organizations, in order to manage and improve their production processes. The approach is referred as total quality management (TQM). This study will discuss the implementation of TQ, within the working environment of Nike Inc. One of the major objectives behind the implementation of TQ is to reduce or completely eliminate potential errors and flaws, within the manufacturing...

  7. Quality assurance, quality control and quality audit in diagnostic radiology

    Vassileva, J.

    2009-01-01

    Full text:The lecture aims to present contemporary view of quality assurance in X-Ray diagnosis and its practical realization in Bulgaria. In the lecture the concepts of quality assurance, quality control and clinical audit will be defined and their scope will be considered. An answer of the following questions will be given: why is it necessary to determine the dose of patient in X-ray studies, what is the reference dose level and how it is used for dosimetric quantity which characterized the patient's exposure in X-ray, mammography and CT scans and how they are measured, who conducted the measurement and how to keep the records, what are the variations of doses in identical tests and what defines them? The findings from a national survey of doses in diagnostic radiology, conducted in 2008-2009 and the developed new national reference levels will be presented. The main findings of the first tests of radiological equipment and the future role of quality control as well as the concept of conducting clinical audit and its role in quality assurance are also presented. Quality assurance of the diagnostic process with minimal exposure of patients is a strategic goal whose realization requires understanding, organization and practical action, both nationally and in every hospital. To achieve this the important role of education and training of physicians, radiological technicians and medical physicists is enhanced

  8. Quality control of imaging devices

    Soni, P.S.

    1992-01-01

    Quality assurance in nuclear medicine refers collectively to all aspects of a nuclear medicine service. It would include patient scheduling, radiopharmaceutical preparation and dispensing, radiation protection of patients, staff and general public, preventive maintenance and the care of instruments, methodology, data interpretation and records keeping, and many other small things which contribute directly or indirectly to the overall quality of a nuclear medicine service in a hospital. Quality Control, on the other hand, refers to a signal component of the system and is usually applied in relation to a specific instrument and its performance

  9. Quality control for dose calibrators

    Mendes, L.C.G.

    1984-01-01

    Nuclear medicine laboratories are required to assay samples of radioactivity to be administered to patients. Almost universally, these assays are accomplished by use of a well ionization chamber isotope calibrator. The Instituto de Radioprotecao e Dosimetria (Institute for Radiological Protection and Dosimetry) of the Comissao Nacional de Energia Nuclear (National Commission for Nuclear Energy) is carrying out a National Quality Control Programme in Nuclear Medicine, supported by the International Atomic Energy Agency. The assessment of the current needs and practices of quality control in the entire country of Brazil includes Dose Calibrators and Scintillation Cameras, but this manual is restricted to the former. Quality Control Procedures for these Instruments are described in this document together with specific recommendations and assessment of its accuracy. (author)

  10. Global nuclear material flow/control model

    Dreicer, J.S.; Rutherford, D.S.; Fasel, P.K.; Riese, J.M.

    1997-01-01

    This is the final report of a two-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The nuclear danger can be reduced by a system for global management, protection, control, and accounting as part of an international regime for nuclear materials. The development of an international fissile material management and control regime requires conceptual research supported by an analytical and modeling tool which treats the nuclear fuel cycle as a complete system. The prototype model developed visually represents the fundamental data, information, and capabilities related to the nuclear fuel cycle in a framework supportive of national or an international perspective. This includes an assessment of the global distribution of military and civilian fissile material inventories, a representation of the proliferation pertinent physical processes, facility specific geographic identification, and the capability to estimate resource requirements for the management and control of nuclear material. The model establishes the foundation for evaluating the global production, disposition, and safeguards and security requirements for fissile nuclear material and supports the development of other pertinent algorithmic capabilities necessary to undertake further global nuclear material related studies

  11. Frontiers in statistical quality control

    Wilrich, Peter-Theodor

    1997-01-01

    Like the preceding volumes, and met with a lively response, the present volume is collecting contributions stressed on methodology or successful industrial applications. The papers are classified under four main headings: sampling inspection, process quality control, data analysis and process capability studies and finally experimental design.

  12. HydroGrid: Technologies for Global Water Quality and Sustainability

    Yeghiazarian, L.

    2017-12-01

    Humans have been transforming planet Earth for millennia. We have recently come to understand that the collective impact of our decisions and actions has brought about severe water quality problems, which are likely to worsen in the light of rapid population growth to the projected nine billion by 2050. To sustainably manage our global water resources and possibly reverse these effects requires efforts in real-time monitoring of water contamination, analysis of monitoring data, and control of the state of water contamination. We develop technologies to address all three areas: monitoring, analysis and control. These efforts are carried out in the conceptual framework of the HydroGrid, an interconnected water system, which is (1) firmly rooted in the fundamental understanding of processes that govern microbial dynamics on multiple scales; and (2) used to develop watershed-specific management strategies. In the area of monitoring we are developing mobile autonomous sensors to detect surface water contamination, an effort supported by extensive materials research to provide multifunctional materials. We analyze environmental data within a stochastic modeling paradigm that bridges microscopic particle interactions to macroscopic manifestation of microbial population behavior in time and space in entire watersheds. These models are supported with laboratory and field experiments. Finally, we combine control and graph theories to derive controllability metrics of natural watersheds.

  13. Global modelling of river water quality under climate change

    van Vliet, Michelle T. H.; Franssen, Wietse H. P.; Yearsley, John R.

    2017-04-01

    Climate change will pose challenges on the quality of freshwater resources for human use and ecosystems for instance by changing the dilution capacity and by affecting the rate of chemical processes in rivers. Here we assess the impacts of climate change and induced streamflow changes on a selection of water quality parameters for river basins globally. We used the Variable Infiltration Capacity (VIC) model and a newly developed global water quality module for salinity, temperature, dissolved oxygen and biochemical oxygen demand. The modelling framework was validated using observed records of streamflow, water temperature, chloride, electrical conductivity, dissolved oxygen and biochemical oxygen demand for 1981-2010. VIC and the water quality module were then forced with an ensemble of bias-corrected General Circulation Model (GCM) output for the representative concentration pathways RCP2.6 and RCP8.5 to study water quality trends and identify critical regions (hotspots) of water quality deterioration for the 21st century.

  14. Quality assurance and statistical control

    Heydorn, K.

    1991-01-01

    In scientific research laboratories it is rarely possible to use quality assurance schemes, developed for large-scale analysis. Instead methods have been developed to control the quality of modest numbers of analytical results by relying on statistical control: Analysis of precision serves...... to detect analytical errors by comparing the a priori precision of the analytical results with the actual variability observed among replicates or duplicates. The method relies on the chi-square distribution to detect excess variability and is quite sensitive even for 5-10 results. Interference control...... serves to detect analytical bias by comparing results obtained by two different analytical methods, each relying on a different detection principle and therefore exhibiting different influence from matrix elements; only 5-10 sets of results are required to establish whether a regression line passes...

  15. Improving the delivery of global tobacco control.

    Bitton, Asaf; Green, Carol; Colbert, James

    2011-01-01

    Tobacco control must remain a critical global health priority given the growing burden of tobacco-induced disease in the developing world. Insights from the emerging field of global health delivery suggest that tobacco control could be improved through a systematic, granular analysis of the processes through which it is promoted, implemented, and combated. Using this framework, a critical bottleneck to the delivery of proven health promotion emerges in the role that the tobacco industry plays in promoting tobacco use and blocking effective tobacco-control policies. This "corporate bottleneck" can also be understood as a root cause of massive disease and suffering upon vulnerable populations worldwide, for the goal of maximizing corporate profit. Naming, understanding, and responding to this corporate bottleneck is crucial to the success of tobacco-control policies. Three case studies of tobacco-control policy--South Africa, the Framework Convention on Tobacco Control, and Uruguay--are presented to explore and understand the implications of this analysis. © 2011 Mount Sinai School of Medicine.

  16. Quality Assurance/Quality Control Jobs

    Fanslau, Melody; Young, Janelle

    The production of a quality and safe food product is essential to the success of any food manufacturing facility. Because of this great importance, a career in quality can be extremely rewarding. Without happy customers willing to buy a product, a company would not be able to survive. Quality issues such as foreign objects, spoiled or mislabeled product, failure to meet net weight requirements, or a recall can all turn customers away from buying a product. The food industry is a customer-driven market in which some consumers are brand loyal based on a history of high quality or in which a single bad experience with a product will turn them away for a lifetime. With this said, the main role of a quality department is to help ensure that quality issues such as these are eliminated or kept to a minimum to maintain or increase the number of customers purchasing their product.

  17. Control of quality in mammography

    2006-10-01

    The present protocol of quality control/quality assurance in mammography is the result of the work of two regional projects realised in Latin America within the frame of ARCAL with the support of the IAEA. The first is ARCAL LV (RLA/6/043) project on quality assurance/quality control in mammography studies which analysed the present situation of the mammography in the member countries of the project which include: Bolivia, Colombia, Costa Rica, Cuba, El Salvador, Guatemala, Nicaragua, Panama, Paraguay, Peru, Dominican Republic and Republic of Venezuela and the second is ARCAL XLIX (RLA/9/035) project, whose members were Brazil, Colombia, Cuba, Chile, Mexico, and Peru, worked the application of Basic Safety Standards for the protection against ionising radiation with the aim to improve radiation protection in X-ray diagnosis medical practices through the implementation of the Basic Safety Standards (BSS) related to x-ray diagnosis in selected hospitals located in each country involved in the project. The work of both projects had been consolidated and harmonized in the present publication

  18. quality control of the radiopharmaceuticals

    Boukarra, Hajer; Boubakri, Rania

    2006-01-01

    This work is a contribution to the quality control of two radio pharmaceutical. Our study was carried out on the rat. These results enable us to draw the following conclusions: - the control of the purity of the cerebral tracers (Cytectrenes) is carried out by HPLC by using a detector of radioactivity which offers a great sensitivity. - the radiochemical output of marking of Kit MDP determined by thin chromatography of layer is 99%. - The study of the biodistribution in the rat showed an affinity raised for the feet bone. - These results are in conformity with the European pharmacopoeia, which enables us to require a marketing authorization. (author)

  19. Radiation measurements and quality control

    McLaughlin, W.L.

    1977-01-01

    Accurate measurements are essential to research leading to a successful radiation process and to the commissioning of the process and the facility. On the other hand, once the process is in production, the importance to quality control of measuring radiation quantities (i.e., absorbed dose, dose rate, dose distribution) rather than various other parameters of the process (i.e. conveyor speed, dwell time, radiation field characteristics, product dimensions) is not clearly established. When the safety of the product is determined by the magnitude of the administered dose, as in radiation sterilization, waste control, or food preservation, accuracy and precision of the measurement of the effective dose are vital. Since physical dose measurements are usually simpler, more reliable and reproducible than biological testing of the product, there is a trend toward using standardized dosimetry for quality control of some processes. In many industrial products, however, such as vulcanized rubber, textiles, plastics, coatings, films, wire and cable, the effective dose can be controlled satisfactorily by controlling process variables or by product testing itself. In the measurement of radiation dose profiles by dosimetry, it is necessary to have suitable dose meter calibrations, to account for sources of error and imprecision, and to use correct statistical procedures in specifying dwell times or conveyor speeds and source and product parameters to achieve minimum and maximum doses within specifications. (author)

  20. Metrology and quality control handbook

    Hofmann, D.

    1983-01-01

    This book tries to present the fundamentals of metrology and quality control in brief surveys. Compromises had to be made in order to reduce the material available to a sensible volume for the sake of clarity. This becomes evident by the following two restrictions which had to made: First, in dealing with the theoretical principles of metrology and quality control, mere reference had to be made in many cases to the great variety of special literature without discussing it to explain further details. Second, in dealing with the application of metrology and quality control techniques in practice, only the basic qantities of the International System of Units (SI) could be taken into account as a rule. Some readers will note that many special measuring methods and equipment known to them are not included in this book. I do hope, however, that this short-coming will show to have a positive effect, too. This book will show the reader how to find the basic quantities and units from the derived quantities and units, and the steps that are necessary to solve any kind of measuring task. (orig./RW) [de

  1. Overview of NASA's Observations for Global Air Quality

    Kaye, J. A.

    2015-12-01

    Observations of pollutants are central to the study of air quality. Much focus has been placed on local-scale observations that can help specific geographic areas document their air quality issues, plan abatement strategies, and understand potential impacts. In addition, long-range atmospheric transport of pollutants can cause downwind regions to not meet attainment standards. Satellite observations have shed significant light on air quality from local to regional to global scales, especially for pollutants such as ozone, aerosols, carbon monoxide, sulfur dioxide, and nitrogen dioxide. These observations have made use of multiple techniques and in some cases multiple satellite sensors. The satellite observations are complemented by surface observations, as well as atmospheric (in situ) observations typically made as part of focused airborne field campaigns. The synergy between satellite observations and field campaigns has been an important theme for recent and upcoming activities and plans. In this talk, a review of NASA's investments in observations relevant to global air quality will be presented, with examples given for a range of pollutants and measurement approaches covering the last twenty-five years. These investments have helped build national and international collaborations such that the global satellite community is now preparing to deploy a constellation of satellites that together will provide fundamental advances in global observations for air quality.

  2. Quality control in nuclear medicine

    Kostadinova, I.

    2007-01-01

    Nuclear medicine comprises diagnosis and therapy of the diseases with radiopharmaceuticals. The ambition of all specialists in our country is their activity to reach European standards. In this connection, a Commission for external audit was formed to evaluate the quality of work in the centers of nuclear medicine. This Commission create a long-lasting programme based on the objective European criteria and the national standard of nuclear medicine, having in mind to increase quality of the work and the expert evaluation of activity in every center. The program comprises measures for quality control of instrumentation, radiopharmaceuticals, performed investigations, obtained results and the whole organization from the receiving of the isotopes to the results of the patients. The ambition is most of the centers to fulfill the requirements. As a conclusion it could be said that not only the quality of everyday nuclear medicine work is enough to increase the prestige of the specialty. It is also necessary we to have understanding expert and financial support from corresponding institutions, incl. Ministry of health for a delivery of a new, contemporary instrumentation with new possibilities. Thus it would be possible Bulgarian patients to reach the high technology apparatuses for an early functional diagnosis of the diseases and optimal treatment, which possibility have the patients from the developed countries. (author)

  3. Quality control programme for radiotherapy

    Campos de Araujo, A.M.; Viegas, C.C.B.; Viamonte, A.M.

    2002-01-01

    A 3 years pilot programme started in January 2000 with 33 philanthropic cancer institutions that provides medical services to 60% of the patients from the national social security system. Brazil has today 161 radiotherapy services (144 operating with megavoltage equipment). These 33 institutions are distributed over 19 Brazilian states. The aim of this programme is: To create conditions to allow the participants to apply the radiotherapy with quality and efficacy; To promote up dating courses for the physicians, physicists and technicians of these 33 Institutions. With the following objectives: To recommend dosimetric and radiological protection procedures in order to guarantee the tumor prescribed dose and safe working conditions; To help in establishing and implementing these procedures. The main activities are: local quality control evaluations, postal TLD audits in reference conditions, postal TLD audits in off axis conditions and training. The local quality control program has already evaluated 22 institutions with 43 machines (25 Co-60 and 18 linear accelerators). In these visits we perform dosimetric, electrical, mechanical and safety tests. As foreseen, we found more problems among the old Co-60 machines i.e., field flatness, size, symmetry and relative output factors; lasers positioning system alignment; optical distance indicator; radiation and light field coincidence; optical and mechanical distance indicators agreement, than among the linear accelerators i.e., field flatness and size; lasers positioning system alignment; tray interlocking and wedge filter factors

  4. Family Control and Earnings Quality

    Carolina Bona Sánchez

    2007-06-01

    Full Text Available El trabajo analiza la relación entre el control familiar y la calidad de la información contable en un contexto en el que el tradicional conflicto de agencia entre directivos y accionistas se desplaza a la divergencia de intereses entre accionistas controladores y minoritarios. Los resultados alcanzados muestran que, en comparación con las no familiares, las empresas de naturaleza familiar divulgan unos resultados de mayor calidad, tanto en términos de menores ajustes por devengo discrecionales como de mayor capacidad de los componentes actuales del resultado para predecir los cash flows futuros. Además, el aumento en los derechos de voto en manos de la familia controladora incrementa la calidad de los resultados contables. La evidencia obtenida se muestra consistente con la presencia de un efecto reputación/vinculación a largo plazo asociado a la empresa familiar. Adicionalmente, el trabajo refleja que a medida que disminuye la divergencia entre los derechos de voto y de cash flow en manos de la familia controladora, aumenta la calidad de la información contable.PALABRAS CLAVE: derechos de voto, divergencia, empresa familiar, calidad delresultado, reputación, beneficios privados.This work examines the relationship between family control and earnings quality in a context where the salient agency problem shifts away from the classical divergence between managers and shareholders to conflicts between the controlling owner and minority shareholders. The results reveal that, compared to non-family firms, family firms reveal higher earnings quality in terms of both lower discretionary accruals and greater predictability of future cash flows. They also show a positive relationship between the level of voting rights held by the controlling family and earnings quality. The evidence is consistent with the presence of a reputation/long-term involvement effect associated with the family firm. Moreover, the work reflects that, as the divergence

  5. Physicians, radiologists, and quality control

    Payne, W.F.

    1973-01-01

    Factors involved in quality control in medical x-ray examinations to achieve the least possible exposure to the patient are discussed. It would be hoped that film quality will remain in the position of paramount importance that it must in order to achieve the greatest amount of diagnostic information on each radiographic examination. At the same time, it is hoped that this can be done by further reducing the exposure of the patient to ionizing radiation by the methods that have been discussed; namely, education of the physician, radiologist, and technologist, modern protective equipment and departmental construction, efficient collimation whether automatic or manual, calibration and output measurement of the radiographic and fluoroscopic units, ongoing programs of education within each department of radiographic facility, film badge monitoring, education of and cooperation with the nonradiologic physician, and hopefully, more intensive programs by the National and State Bureaus and Departments of Radiological Health in education and encouragement to the medical community. (U.S.)

  6. Quality control of pesticide products

    NONE

    2009-07-15

    In light of an established need for more efficient analytical procedures, this publication, which documents the findings of an IAEA coordinated research project (CRP) on “Quality Control of Pesticide Products”, simplifies the existing protocol for pesticide analysis while simultaneously upholding existing standards of quality. This publication includes both a report on the development work done in the CRP and a training manual for use by pesticide analysis laboratories. Based on peer reviewed and internationally recognized methods published by the Association of Analytical Communities (AOAC) and the Collaborative International Pesticides Analytical Council (CIPAC), this report provides laboratories with versatile tools to enhance the analysis of pesticide chemicals and to extend the scope of available analytical repertoires. Adoption of the proposed analytical methodologies promises to reduce laboratories’ use of solvents and the time spent on reconfiguration and set-up of analytical equipment.

  7. Quality control of pesticide products

    2009-07-01

    In light of an established need for more efficient analytical procedures, this publication, which documents the findings of an IAEA coordinated research project (CRP) on “Quality Control of Pesticide Products”, simplifies the existing protocol for pesticide analysis while simultaneously upholding existing standards of quality. This publication includes both a report on the development work done in the CRP and a training manual for use by pesticide analysis laboratories. Based on peer reviewed and internationally recognized methods published by the Association of Analytical Communities (AOAC) and the Collaborative International Pesticides Analytical Council (CIPAC), this report provides laboratories with versatile tools to enhance the analysis of pesticide chemicals and to extend the scope of available analytical repertoires. Adoption of the proposed analytical methodologies promises to reduce laboratories’ use of solvents and the time spent on reconfiguration and set-up of analytical equipment

  8. Water quality control system and water quality control method

    Itsumi, Sachio; Ichikawa, Nagayoshi; Uruma, Hiroshi; Yamada, Kazuya; Seki, Shuji

    1998-01-01

    In the water quality control system of the present invention, portions in contact with water comprise a metal material having a controlled content of iron or chromium, and the chromium content on the surface is increased than that of mother material in a state where compression stresses remain on the surface by mechanical polishing to form an uniform corrosion resistant coating film. In addition, equipments and/or pipelines to which a material controlling corrosion potential stably is applied on the surface are used. There are disposed a cleaning device made of a material less forming impurities, and detecting intrusion of impurities and removing them selectively depending on chemical species and/or a cleaning device for recovering drain from various kinds of equipment to feedwater, connecting a feedwater pipeline and a condensate pipeline and removing impurities and corrosion products. Then, water can be kept to neutral purified water, and the concentrations of oxygen and hydrogen in water are controlled within an optimum range to suppress occurrence of corrosion products. (N.H.)

  9. Quality control in breast tomosynthesis

    Jakubiak, Rosangela Requi; Messias, Pricila Cordeiro; Santos, Marilia Fernanda; Urban, Linei Augusta B.D.

    2014-01-01

    In Brazil breast cancer is the most common and the leading cause of death among women, with estimated 57,000 new cases in 2014. The mammography (2D) plays an important role in the early detection of breast cancer, but in some cases can be difficult to detect malignant lesions due overlap of breast tissues. The Breast Digital Tomosynthesis (BDT: 3D) reduces the effects of overlap, providing improved characterization of mammographic findings. However, the dose may double as compared to the mammography. This study presents results of Contrast Ratio Noise tests (CRN) and quality image on a Siemens mammography equipment Mammomat Inspiration with tomosynthesis. The CRN was determined with plates Polymethylmethacrylate (PMMA) of 20 to 70 mm thickness and an aluminum plate of 10 mm 2 and 0.2 mm thickness. Image quality was assessed with the ACR Breast Simulator. In assessment of image quality, the detectability of fibers and masses was identical in 2D and 3D systems. Were visualized 4.5 fibers and 4 mass in both modes. In 2D mode groups have been identified 3.5 microcalcifications, and 3D were 3 groups. The Mean Glandular Dose for the simulator in 2D mode was 1.17 mGy and 2.35 mGy for the 3D mode. The result reinforces the importance of quality control in the process of obtaining the images and obtained in accordance CRN values, ensuring image quality and dose compatible in 2D and 3D processes

  10. Quality control in breast tomosynthesis

    Jakubiak, R.R.; Messias, P.C.; Santos, M.F., E-mail: requi@utfpr.edu.br [Universidade Tecnologia Federal do Parana (UTFPR), Curitiba, PR (Brazil). Departamento Academico de Fisica; Urban, L.A.B.D., E-mail: lineiurban@hotmail.com [Diagnostico Avancado por Imagem, Curitiba, PR (Brazil)

    2015-07-01

    In Brazil, breast cancer is the most common and the leading cause of death among women, with estimated 57,000 new cases in 2014. The mammography (2D) plays an important role in the early detection of breast cancer, but in some cases can be difficult to detect malignant lesions due overlap of breast tissues. The Digital Breasts Tomosynthesis (DBT: 3D) reduces the effects of overlap, providing improved characterization of mammographic findings. However, the dose may double as compared with mammography. This study presents results of Contrast to Noise Ratio (CNR) and image quality evaluation on Siemens mammography equipment Mammomat Inspiration with tomosynthesis. The CNR was determined with Polymethylmethacrylate (PMMA) layers of 20 to 70 mm thick and an aluminum foils of 0,2 mm thickness and area of 10 mm². Image quality was assessed with the ACR Breast Simulator. In the evaluation of image quality, the detectability of fibers and masses was identical in 2D and 3D systems. Displaying fibers were 4,5 and 4 mass in both modes. In 2D mode were identified 3,5 microcalcifications groups, and 3D showed 3 groups. The Mean Glandular Dose (MGD) for the simulator in 2D mode was 1,17 mGy and 2,35 mGy for the 3D mode. The result reinforces the importance of quality control in the process of obtaining the images and obtained in accordance CNR values, ensuring image quality and compatible dose in 2D and 3D processes. (author)

  11. Quality control in breast tomosynthesis

    Jakubiak, R.R.; Messias, P.C.; Santos, M.F.

    2015-01-01

    In Brazil, breast cancer is the most common and the leading cause of death among women, with estimated 57,000 new cases in 2014. The mammography (2D) plays an important role in the early detection of breast cancer, but in some cases can be difficult to detect malignant lesions due overlap of breast tissues. The Digital Breasts Tomosynthesis (DBT: 3D) reduces the effects of overlap, providing improved characterization of mammographic findings. However, the dose may double as compared with mammography. This study presents results of Contrast to Noise Ratio (CNR) and image quality evaluation on Siemens mammography equipment Mammomat Inspiration with tomosynthesis. The CNR was determined with Polymethylmethacrylate (PMMA) layers of 20 to 70 mm thick and an aluminum foils of 0,2 mm thickness and area of 10 mm². Image quality was assessed with the ACR Breast Simulator. In the evaluation of image quality, the detectability of fibers and masses was identical in 2D and 3D systems. Displaying fibers were 4,5 and 4 mass in both modes. In 2D mode were identified 3,5 microcalcifications groups, and 3D showed 3 groups. The Mean Glandular Dose (MGD) for the simulator in 2D mode was 1,17 mGy and 2,35 mGy for the 3D mode. The result reinforces the importance of quality control in the process of obtaining the images and obtained in accordance CNR values, ensuring image quality and compatible dose in 2D and 3D processes. (author)

  12. Quality assurance and quality control for Hydro-Quebec's ambient air monitoring networks

    Lambert, M.; Varfalvy, L.

    1993-01-01

    Hydro Quebec has three ambient air monitoring networks to determine the contribution of some of its thermal plants to ambient air quality. They are located in Becancour (gas turbines), Iles-de-la-Madeleine (diesel), and Tracy (conventional oil-fired). To ensure good quality results and consistency between networks, a quality assurance/quality control program was set up. A description is presented of the ambient air quality monitoring network and the quality assurance/quality control program. A guide has been created for use by the network operators, discussing objectives of the individual network, a complete description of each network, field operation for each model of instrument in use, treatment of data for each data logger in use, global considerations regarding quality assurance and control, and reports. A brief overview is presented of the guide's purpose and contents, focusing on the field operation section and the sulfur dioxide and nitrogen oxide monitors. 6 figs., 1 tab

  13. 40 CFR 51.359 - Quality control.

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Quality control. 51.359 Section 51.359....359 Quality control. Quality control measures shall insure that emission testing equipment is calibrated and maintained properly, and that inspection, calibration records, and control charts are...

  14. Can air pollutant controls change global warming?

    Strefler, Jessica; Luderer, Gunnar; Kriegler, Elmar; Meinshausen, Malte

    2014-01-01

    Highlights: • Air pollution policies do not affect long-term climate targets. • Reduction of aerosols counteracts a fraction of the reduction of Kyoto forcing. • Air pollution policies may affect the rate of climate change in the short term. • There is no tradeoff between clean air and climate policies. - Abstract: In this paper we analyze the interaction between climate and air pollution policies using the integrated assessment model REMIND coupled to the reduced-form climate model MAGICC. Since overall, aerosols tend to cool the atmosphere, there is a concern that a reduction of pollutant emissions could accelerate global warming and offset the climate benefits of carbon dioxide emission reductions. We investigate scenarios which independently reduce emissions from either large-scale sources, such as power plants, or small-scale sources, such as cooking and heating stoves. Large-scale sources are likely to be easier to control, but their aerosol emissions are characterized by a relatively high sulfur content, which tends to result in atmospheric cooling. Pollution from small-scale sources, by contrast, is characterized by a high share of carbonaceous aerosol, which is an important contributor to global warming. We find that air pollution policies can significantly reduce aerosol emissions when no climate policies are in place. Stringent climate policies lead to a large reduction of fossil fuel use, and therefore result in a concurrent reduction of air pollutant emissions. These reductions partly reduce aerosol masking, thus initially counteracting the reduction of greenhouse gas forcing, however not overcompensating it. If climate policies are in place, air pollution policies have almost no impacts on medium- and long-term radiative forcing. Therefore there is no conflict of objectives between clean air and limiting global warming. We find that the stringency of air pollution policies may influence the rate of global temperature change in the first decade

  15. Dispositional Optimism and Terminal Decline in Global Quality of Life

    Zaslavsky, Oleg; Palgi, Yuval; Rillamas-Sun, Eileen; LaCroix, Andrea Z.; Schnall, Eliezer; Woods, Nancy F.; Cochrane, Barbara B.; Garcia, Lorena; Hingle, Melanie; Post, Stephen; Seguin, Rebecca; Tindle, Hilary; Shrira, Amit

    2015-01-01

    We examined whether dispositional optimism relates to change in global quality of life (QOL) as a function of either chronological age or years to impending death. We used a sample of 2,096 deceased postmenopausal women from the Women's Health Initiative clinical trials who were enrolled in the 2005-2010 Extension Study and for whom at least 1…

  16. 2. Product quality control and assurance system

    1990-01-01

    Product quality control and assurance are dealt with in relation to reliability in nuclear power engineering. The topics treated include product quality control in nuclear power engineering, product quality assurance of nuclear power plant equipment, quality assurance programs, classification of selected nuclear power equipment, and standards relating to quality control and assurance and to nuclear power engineering. Particular attention is paid to Czechoslovak and CMEA standards. (P.A.). 2 figs., 1 tab., 12 refs

  17. Internal quality control: best practice.

    Kinns, Helen; Pitkin, Sarah; Housley, David; Freedman, Danielle B

    2013-12-01

    There is a wide variation in laboratory practice with regard to implementation and review of internal quality control (IQC). A poor approach can lead to a spectrum of scenarios from validation of incorrect patient results to over investigation of falsely rejected analytical runs. This article will provide a practical approach for the routine clinical biochemistry laboratory to introduce an efficient quality control system that will optimise error detection and reduce the rate of false rejection. Each stage of the IQC system is considered, from selection of IQC material to selection of IQC rules, and finally the appropriate action to follow when a rejection signal has been obtained. The main objective of IQC is to ensure day-to-day consistency of an analytical process and thus help to determine whether patient results are reliable enough to be released. The required quality and assay performance varies between analytes as does the definition of a clinically significant error. Unfortunately many laboratories currently decide what is clinically significant at the troubleshooting stage. Assay-specific IQC systems will reduce the number of inappropriate sample-run rejections compared with the blanket use of one IQC rule. In practice, only three or four different IQC rules are required for the whole of the routine biochemistry repertoire as assays are assigned into groups based on performance. The tools to categorise performance and assign IQC rules based on that performance are presented. Although significant investment of time and education is required prior to implementation, laboratories have shown that such systems achieve considerable reductions in cost and labour.

  18. The ‘Alternative Quality Contract’ in Massachusetts, Based on Global Budgets, Lowered Medical Spending and Improved Quality

    Song, Zirui; Safran, Dana Gelb; Landon, Bruce E.; Landrum, Mary Beth; He, Yulei; Mechanic, Robert E.; Day, Matthew P.; Chernew, Michael E.

    2012-01-01

    Seven provider organizations in Massachusetts entered the Blue Cross Blue Shield Alternative Quality Contract in 2009, followed by four more organizations in 2010. This contract, based on a global budget and pay-for-performance for achieving certain quality benchmarks, places providers at risk for excessive spending and rewards them for quality, similar to the new Pioneer Accountable Care Organizations in Medicare. We analyzed changes in spending and quality associated with the Alternative Quality Contract and found that the rate of increase in spending slowed compared to control groups. Overall, participation in the contract over two years led to a savings of 3.3% (1.9% in year-1, 3.3% in year-2) compared to spending in groups not participating in the contract. The savings were even higher for groups whose previous experience had been only in fee-for-service contracting. Such groups’ quarterly savings over two years averaged 8.2% (6.3% in year-1, 9.9% in year-2). Quality of care also improved within organizations participating in the Alternative Quality Contract compared to control organizations in both years. Chronic care management, adult preventive care, and pediatric care improved from year 1 to year 2 within the contracting groups. These results suggest that global budgets coupled with pay-for-performance can begin to slow the underlying growth in medical spending while improving quality. PMID:22786651

  19. Three Eras in Global Tobacco Control: How Global Governance Processes Influenced Online Tobacco Control Networking.

    Wipfli, Heather; Chu, Kar-Hai; Lancaster, Molly; Valente, Thomas

    2016-01-01

    Online networks can serve as a platform to diffuse policy innovations and enhance global health governance. This study focuses on how shifts in global health governance may influence related online networks. We compare social network metrics (average degree centrality [AVGD], density [D] and clustering coefficient [CC]) of Globalink, an online network of tobacco control advocates, across three eras in global tobacco control governance; pre-Framework Convention on Tobacco Control (FCTC) policy transfer (1992-1998), global regime formation through the FCTC negotiations (1999-2005), and philanthropic funding through the Bloomberg Initiative (2006-2012). Prior to 1999, Globalink was driven by a handful of high-income countries (AVGD=1.908 D=0.030, CC=0.215). The FCTC negotiations (1999-2005) corresponded with a rapid uptick in the number of countries represented within Globalink and new members were most often brought into the network through relationships with regional neighbors (AVGD=2.824, D=0.021, CC=0.253). Between 2006 and 2012, the centrality of the US in the network increases significantly (AVGD=3.414, D=0.023, CC=0.310). The findings suggest that global institutionalization through WHO, as with the FCTC, can lead to the rapid growth of decentralized online networks. Alternatively, private initiatives, such as the Bloomberg Initiative, can lead to clustering in which a single source of information gains increasing influence over an online network.

  20. Renewing focus on family planning service quality globally.

    Hancock, Nancy L; Stuart, Gretchen S; Tang, Jennifer H; Chibwesha, Carla J; Stringer, Jeffrey S A; Chi, Benjamin H

    2016-01-01

    Reducing the global unmet need for contraception is currently a priority for many governments, multi-lateral initiatives, non-governmental organizations, and donors. Evidence strongly suggests that the provision of quality family planning services can increase uptake, prevalence, and continuation of contraception. While an accepted framework to define the components of family planning service quality exists, translating this framework into assessment tools that are accessible, easily utilized, and valid for service providers has remained a challenge. We propose new approaches to improve the standardization and accessibility of family planning service quality assessment tools to simplify family planning service quality evaluation. With easier approaches to program evaluation, quality improvements can be performed more swiftly to help increase uptake and continuation of contraception to improve the health of women and their families.

  1. 14 CFR 21.139 - Quality control.

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Quality control. 21.139 Section 21.139... PROCEDURES FOR PRODUCTS AND PARTS Production Certificates § 21.139 Quality control. The applicant must show that he has established and can maintain a quality control system for any product, for which he...

  2. Quality and reliability control on assemblies

    Mueller, H.

    1976-01-01

    Taking as an example electronic assemblies in printed circuit board engineering, quality control during manufacture is dealt with. After giving a survey of four phases of quality and reliability control, some specific methods of quality control are dealt with by means of a flowchart, and by some examples the necessity and the success of these measures are shown. (RW) [de

  3. 7 CFR 930.44 - Quality control.

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Quality control. 930.44 Section 930.44 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Control § 930.44 Quality control. (a) Quality standards. The Board may establish, with the approval of the...

  4. 33 CFR 385.21 - Quality control.

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Quality control. 385.21 Section... Processes § 385.21 Quality control. (a) The Corps of Engineers and the non-Federal sponsor shall prepare a quality control plan, in accordance with applicable Corps of Engineers regulations, for each product that...

  5. 7 CFR 981.42 - Quality control.

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Quality control. 981.42 Section 981.42 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Regulating Handling Quality Control § 981.42 Quality control. (a) Incoming. Except as provided in this...

  6. Association between product quality control and process quality control of bulk milk

    Velthuis, A.; Asseldonk, van M.A.P.M.

    2010-01-01

    Assessment of dairy-milk quality is based on product quality control (testing bulk-milk samples) and process quality control (auditing dairy farms). It is unknown whether process control improves product quality. To quantify possible association between product control and process control a

  7. Quality control analysis at the hospital

    Kristensen, K.

    1979-01-01

    Quality control analysis is an integral part of quality assurance. In a system as with radiopharmaceuticals where part of the finishing of the product takes place at individual hospitals, the need for quality control analysis at the hospital can be discussed. Data are presented that stresses the importance of quality control by the manufacturer as a basis for limitation of such work at hospitals. A simplified programme is proposed

  8. Quality control guarantees the safety of radiotherapy

    Aaltonen, P.

    1994-01-01

    While radiotherapy equipment has seen some decisive improvements in the last few decades, the technology has also become more complicated. The advanced equipment produces increasingly good treatment results, but the condition of the equipment must be controlled efficiently so as to eliminate any defects that might jeopardise patient safety. The quality assurance measures that are taken to show that certain equipment functions as required are known as quality control. The advanced equipment and stricter requirements set for the precision of radiotherapy have meant that more attention must be paid to quality control. The present radiation legislation stipulates that radiotherapy equipment must undergo regular quality control. The implementation of the quality control is supervised by the Finnish Centre for Radiation and Nuclear Safety (STUK). Hospitals carry out quality control in accordance with a programme approved by STUK, and STUK inspectors periodically visit hospitals to check the results of quality control. (orig.)

  9. Radiopharmaceutical quality control-Pragmatic approach

    Barbier, Y.

    1994-01-01

    The quality control must be considered in a practical manner. The radiopharmaceuticals are drugs. They must satisfy the quality assurance control. These products are then conform to Pharmacopeia. But sometimes the user must control some data especially radiochemical purity and pH value. On all the administered solutions four controls are compulsory: radionuclide identity, administered radioactivity, organoleptic character and pH

  10. Expert database system for quality control

    Wang, Anne J.; Li, Zhi-Cheng

    1993-09-01

    There are more competitors today. Markets are not homogeneous they are fragmented into increasingly focused niches requiring greater flexibility in the product mix shorter manufacturing production runs and above allhigher quality. In this paper the author identified a real-time expert system as a way to improve plantwide quality management. The quality control expert database system (QCEDS) by integrating knowledge of experts in operations quality management and computer systems use all information relevant to quality managementfacts as well as rulesto determine if a product meets quality standards. Keywords: expert system quality control data base

  11. Quality control of activity detectors

    Surma, M.J.

    2002-01-01

    The conditions decided on radiometric measurements quality as geometry, background, calibration etc. have been described. The testing methods for achieving high quality of radioactivity measurements using nuclear medicine instruments have been recommended

  12. Quality Indicators for Global Benchmarking of Localized Prostate Cancer Management.

    Sampurno, Fanny; Zheng, Jia; Di Stefano, Lydia; Millar, Jeremy L; Foster, Claire; Fuedea, Ferran; Higano, Celestia; Hulan, Hartwig; Mark, Stephen; Moore, Caroline; Richardson, Alison; Sullivan, Frank; Wenger, Neil S; Wittmann, Daniela; Evans, Sue

    2018-03-01

    We sought to develop a core set of clinical indicators to enable international benchmarking of localized prostate cancer management using data available in the TrueNTH (True North) Global Registry. An international expert panel completed an online survey and participated in a face to face meeting. Participants included 3 urologists, 3 radiation oncologists, 2 psychologists, 1 medical oncologist, 1 nurse and 1 epidemiologist with prostate cancer expertise from a total of 7 countries. Current guidelines on prostate cancer treatment and potential quality indicators were identified from a literature review. These potential indicators were refined and developed through a modified Delphi process during which each panelist independently and repeatedly rated each indicator based on importance (satisfying the indicator demonstrated a provision of high quality care) and feasibility (the likelihood that data used to construct the indicator could be collected at a population level). The main outcome measure was items with panel agreement indicted by a disagreement index less 1, median importance 8.5 or greater and median feasibility 9 or greater. The expert panel endorsed 33 indicators. Seven of these 33 prostate cancer quality indicators assessed care relating to diagnosis, 7 assessed primary treatment, 1 assessed salvage treatment and 18 assessed health outcomes. We developed a set of quality indicators to measure prostate cancer care using numerous international evidence-based clinical guidelines. These indicators will be pilot tested in the TrueNTH Global Registry. Reports comparing indicator performance will subsequently be distributed to groups at participating sites with the purpose of improving the consistency and quality of prostate cancer management on a global basis. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  13. 30 CFR 74.6 - Quality control.

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality control. 74.6 Section 74.6 Mineral... of the CMDPSU will be maintained in production through adequate quality control procedures, MSHA and... DUST SAMPLING DEVICES Approval Requirements for Coal Mine Dust Personal Sampler Unit § 74.6 Quality...

  14. Employee quality, monitoring environment and internal control

    Chunli Liu; Bin Lin; Wei Shu

    2017-01-01

    We investigate the effect of internal control employees (ICEs) on internal control quality. Using special survey data from Chinese listed firms, we find that ICE quality has a significant positive influence on internal control quality. We examine the effect of monitoring on this result and find that the effect is more pronounced for firms with strict monitoring environments, especially when the firms implement the Chinese internal control regulation system (CSOX), have higher institutional ow...

  15. Problems of quality assurance and quality control in diagnostic radiology

    Angerstein, W.

    1986-01-01

    Topical problems of quality assurance and quality control in diagnostic radiology are discussed and possible solutions are shown. Complex units are differentiated with reference to physicians, technicians, organization of labour, methods of examination and indication. Quality control of radiologic imaging systems should involve three stages: (1) simple tests carried out by radiologic technicians, (2) measurements by service technicians, (3) testing of products by the manufacturer and independent governmental or health service test agencies. (author)

  16. Quality control in tile production

    Kalviainen, Heikki A.; Kukkonen, Saku; Hyvarinen, Timo S.; Parkkinen, Jussi P. S.

    1998-10-01

    This work studies visual quality control in ceramics industry. In tile manufacturing, it is important that in each set of tiles, every single tile looks similar. For example, the tiles should have similar color and texture. Our goal is to design a machine vision system that can estimate the sufficient similarity or same appearance to the human eye. Currently, the estimation is usually done by human vision. Differing from other approaches our aim is to use accurate spectral representation of color, and we are comparing spectral features to the RGB color features. A laboratory system for color measurement is built. Experimentations with five classes of brown tiles are presented. We use chromaticity RGB features and several spectral features for classification with the k-NN classifier and with a neural network, called Self-Organizing Map. We can classify many of the tiles but there are several problems that need further investigations: larger training and test sets are needed, illuminations effects must be studied further, and more suitable spectral features are needed with more sophisticated classifiers. It is also interesting to develop further the neural approach.

  17. Quality control of ATLAS muon chambers

    Fabich, Adrian

    ATLAS is a general-purpose experiment for the future Large Hadron Collider (LHC) at CERN. Its Muon Spectrometer will require ∼ 5500m2 of precision tracking chambers to measure the muon tracks along a spectrometer arm of 5m to 15m length, embedded in a magnetic field of ∼ 0.5T. The precision tracking devices in the Muon System will be high pressure drift tubes (MDTs). Approximately 370,000 MDTs will be assembled into ∼ 1200 drift chambers. The performance of the MDT chambers is very much dependent on the mechanical quality of the chambers. The uniformity and stability of the performance can only be assured providing very high quality control during production. Gas tightness, high-voltage behaviour and dark currents are global parameters which are common to gas detectors. For all chambers, they will be tested immediately after the chamber assembly at every production site. Functional tests, for example radioactive source scans and cosmic-ray runs, will be performed in order to establish detailed performan...

  18. Shipping/Receiving and Quality Control

    Federal Laboratory Consortium — Shipping receiving, quality control, large and precise inspection and CMM machines. Coordinate Measuring Machines, including "scanning" probes, optical comparators,...

  19. Quality control of static irradiation processing products

    Bao Jianzhong; Chen Xiulan; Cao Hong; Zhai Jianqing

    2002-01-01

    Based on the irradiation processing practice of the nuclear technique application laboratory of Yangzhou Institute of Agricultural Science, the quality control of irradiation processing products is discussed

  20. "Power quality system," a new system of quality management for globalization: towards innovation and competitive advantages.

    Abdul-Rahman, H; Berawi, M A

    Knowledge Management (KM) addresses the critical issues of organizational adoption, survival and competence in the face of an increasingly changing environment. KM embodies organizational processes that seek a synergistic combination of the data and information processing capabilities of information and communication technologies (ICT), and the creative and innovative capacity of human beings to improve ICT In that role, knowledge management will improve quality management and avoid or minimize losses and weakness that usually come from poor performance as well as increase the competitive level of the company and its ability to survive in the global marketplace. To achieve quality, all parties including the clients, company consultants, contractors, entrepreneurs, suppliers, and the governing bodies (i.e., all involved stake-holders) need to collaborate and commit to achieving quality. The design based organizations in major business and construction companies have to be quality driven to support healthy growth in today's competitive market. In the march towards vision 2020 and globalization (i.e., the one world community) of many companies, their design based organizations need to have superior quality management and knowledge management to anticipate changes. The implementation of a quality system such as the ISO 9000 Standards, Total Quality Management, or Quality Function Deployment (QFD) focuses the company's resources towards achieving faster and better results in the global market with less cost. To anticipate the needs of the marketplace and clients as the world and technology change, a new system, which we call Power Quality System (PQS), has been designed. PQS is a combination of information and communication technologies (ICT) and the creative and innovative capacity of human beings to meet the challenges of the new world business and to develop high quality products.

  1. Establishment for quality control of experimental animal

    Kim, Tae Hwan; Kim, Soo Kwan; Kim, Tae Kyoung

    1999-06-01

    Until now, because we have imported experimental animal from foreign experimental animal corporation, we could have saved money by establishing the quality control of animal in barrier system. In order to improve the quality of animal experiment and efficiency of biomedical study, it is indispensable to control many factors that effect in the experiment. Therefore, it is essential to organize the system of laboratory animal care for enhancing reliability and revivability of experimental results. The purpose of the present investigation was to establish the quality control system of experimental animals that we can provide good quality animals according to the experimental condition of each investigator although the exact quality control system to estimate the infection of bacteria and virus easily remains ill-defined yet. Accordingly, we established the useful quality control system for microbiologic monitoring and environmental monitoring to protect experimental animal from harmful bacteria and virus

  2. Establishment for quality control of experimental animal

    Kim, Tae Hwan; Kim, Soo Kwan; Kim, Tae Kyoung

    1999-06-01

    Until now, because we have imported experimental animal from foreign experimental animal corporation, we could have saved money by establishing the quality control of animal in barrier system. In order to improve the quality of animal experiment and efficiency of biomedical study, it is indispensable to control many factors that effect in the experiment. Therefore, it is essential to organize the system of laboratory animal care for enhancing reliability and revivability of experimental results. The purpose of the present investigation was to establish the quality control system of experimental animals that we can provide good quality animals according to the experimental condition of each investigator although the exact quality control system to estimate the infection of bacteria and virus easily remains ill-defined yet. Accordingly, we established the useful quality control system for microbiologic monitoring and environmental monitoring to protect experimental animal from harmful bacteria and virus.

  3. Quality Control in Production Processes

    Prístavka Miroslav

    2016-09-01

    Full Text Available The tools for quality management are used for quality improvement throughout the whole Europe and developed countries. Simple statistics are considered one of the most basic methods. The goal was to apply the simple statistical methods to practice and to solve problems by using them. Selected methods are used for processing the list of internal discrepancies within the organization, and for identification of the root cause of the problem and its appropriate solution. Seven basic quality tools are simple graphical tools, but very effective in solving problems related to quality. They are called essential because they are suitable for people with at least basic knowledge in statistics; therefore, they can be used to solve the vast majority of problems.

  4. Quality control of mammographic systems

    Espana Lopez, M. L.

    2001-01-01

    High quality in mammography is a difficult objective to achieve, that is the reason for what efforts are made in order to improve equipment, to offer good combinations screen-film, and professional staff dedicated to this technique [es

  5. Employee quality, monitoring environment and internal control

    Chunli Liu

    2017-03-01

    Full Text Available We investigate the effect of internal control employees (ICEs on internal control quality. Using special survey data from Chinese listed firms, we find that ICE quality has a significant positive influence on internal control quality. We examine the effect of monitoring on this result and find that the effect is more pronounced for firms with strict monitoring environments, especially when the firms implement the Chinese internal control regulation system (CSOX, have higher institutional ownership or attach greater importance to internal control. Our findings suggest that ICEs play an important role in the design and implementation of internal control systems. Our study should be of interest to both top managers who wish to improve corporate internal control quality and regulators who wish to understand the mechanisms of internal control monitoring.

  6. Quality control education in the community college

    Greene, J. Griffen; Wilson, Steve

    1966-01-01

    This paper describes the Quality Control Program at Daytona Beach Junior College, including course descriptions. The program in quality control required communication between the college and the American Society for Quality Control (ASQC). The college has machinery established for certification of the learning process, and the society has the source of teachers who are competent in the technical field and who are the employers of the educational products. The associate degree for quality control does not have a fixed program, which can serve all needs, any more than all engineering degrees have identical programs. The main ideas which would be common to all quality control programs are the concept of economic control of a repetitive process and the concept of developing individual potentialities into individuals who are needed and productive.

  7. Globalization and Localization of the Management Control System package

    Toldbod, Thomas; Israelsen, Poul

    2015-01-01

    Through an empirical case study, this article examines the operation of multiple management control systems as a package in a Danish manufacturing company. The analysis focuses on four different management control systems – cybernetic controls, planning controls, reward controls, and administrative...... the organization and others have more particular characteristics. Specifically, this study finds that cybernetic controls and administrative controls are designed as global management control systems. Planning controls and reward and compensation controls are glocal systems. The finding leads to the conclusion...... controls – through the theoretical lens of globalization, localization, and glocalization. Based on a single-case study, the analysis documents that these different management control systems are affected differently by the processes of globalization and localization, some of which are universal throughout...

  8. Related regulation of quality control of industrial products

    1983-04-01

    This book introduce related regulation of quality control of industrial products, which includes regulations of industrial products quality control, enforcement ordinance of industrial products quality control, enforcement regulation of quality control of industrial products, designated items with industrial production quality indication, industrial production quality test, and industrial production quality test organization and management tips of factory quality by grade.

  9. Quality control of nuclear medicine instrumentation

    Mould, R.F.

    1983-09-01

    The proceedings of a conference held by the Hospital Physicists' Association in London 1983 on the quality control of nuclear medicine instrumentation are presented. Section I deals with the performance of the Anger gamma camera including assessment during manufacture, acceptance testing, routine testing and long-term assessment of results. Section II covers interfaces, computers, the quality control problems of emission tomography and the quality of software. Section III deals with radionuclide measurement and impurity assessment and Section IV the presentation of images and the control of image quality. (U.K.)

  10. Developing methods of controlling quality costs

    Gorbunova A. V.; Maximova O. N.; Ekova V. A.

    2017-01-01

    The article examines issues of managing quality costs, problems of applying economic methods of quality control, implementation of progressive methods of quality costs management in enterprises with the view of improving the efficiency of their evaluation and analysis. With the aim of increasing the effectiveness of the cost management mechanism, authors introduce controlling as a tool of deviation analysis from the standpoint of the process approach. A list of processes and corresponding eva...

  11. Quality Assurance and Control in Laboratory using Neutron Activation Analysis

    Chung, Y. S.; Moon, J. H.; Sun, G. M.; Kim, S. H.; Baek, S. Y.; Lim, J. M.; Kim, H. R.

    2007-01-01

    In accordance with the increment of international trade associated with the worldwide globalization, the importance of quality assurance and control for the commodity produced from one's own country has been stressed. ISO (International Organization for Standards) defines quality control as 'the operational techniques and activities that are used to fulfill the requirements for quality'. Since 1996, the HANARO research reactor in the Korea Atomic Energy Research Institute has been operated thereafter initial critical operation on April 1995. Neutron activation analysis system and applied techniques which is one of a nuclear analytical technologies using reactor neutrons has been developed for user's supporting and the establishment of the quality system for a measurement and analysis, testing and inspection was implemented successfully. On the basis of the qualified NAA system, the test and measurement of more than 1500 samples which is requested from 30 organizations including industrial companies, universities and institutes carried out in NAA laboratory annually. Moreover, as the goal of mutual recognition agreement (MRA) which can be removed a technical barrier in international trade, the objectivity and the confidence of analytical quality in NAA laboratory became established through the installation of international accreditation system by implementing analytical quality system in accordance with international standards in 2001. The aim of the report was to summarize the technical management of introduction, methods and the results for a quality control and assurance which should be performed in NAA technique using the HANARO research reactor. The report will help building up effective quality control strategy in the future

  12. Fuel manufacture and quality control

    Roepenack, H.; Raab, K.

    1975-01-01

    The different steps in fuel and fuel element manufacturing from the conversion of UF 6 to UO 2 to the assembling of the whole fuel element are shortly described. Each of this fabrication steps must satisfy well-defined quality criteria which are checked in certain analyses or tests. (RB) [de

  13. Quality Control in Mammography: Image Quality and Patient Doses

    Ciraj Bjelac, O.; Arandjic, D.; Boris Loncar, B.; Kosutic, D.

    2008-01-01

    Mammography is method of choice for early detection of breast cancer. The purpose of this paper is preliminary evaluation the mammography practice in Serbia, in terms of both quality control indicators, i.e. image quality and patient doses. The survey demonstrated considerable variations in technical parameters that affect image quality and patients doses. Mean glandular doses ranged from 0.12 to 2.8 mGy, while reference optical density ranged from 1.2 to 2.8. Correlation between image contrast and mean glandular doses was demonstrated. Systematic implementation of quality control protocol should provide satisfactory performance of mammography units and maintain satisfactory image quality and keep patient doses as low as reasonably practicable. (author)

  14. Quality control in the radioactive waste management

    Rzyski, B.M.

    1989-01-01

    Radioactive waste management as in industrial activities must mantain in all steps a quality control programme. This control extended from materials acquisition, for waste treatment, to the package deposition is one of the most important activities because it aims to observe the waste acceptance criteria in repositories and allows to guarantee the security of the nuclear facilities. In this work basic knowledges about quality control in waste management and some examples of adopted procedures in other countries are given. (author) [pt

  15. Quality Control Barriers in Adapting "Metro-Centric" Education to Regional Needs

    Nagy, Judy; Robinson, Susan R.

    2013-01-01

    The massification and globalization of higher education, combined with the widespread adoption of processes underpinning accreditation and quality control of university programs, have tended to result in learning contexts that are increasingly narrowly conceived and tightly controlled. Underlying many quality control measures is a "one size…

  16. Control by quality: proposition of a typology.

    Pujo, P; Pillet, M

    The application of Quality tools and methods in industrial management has always had a fundamental impact on the control of production. It influences the behavior of the actors concerned, while introducing the necessary notions and formalizations, especially for production systems with little or no automation, which constitute a large part of the industrial activity. Several quality approaches are applied in the workshop and are implemented at the level of the control. In this paper, the authors present a typology of the various approaches that have successively influenced control, such as statistical process control, quality assurance, and continuous improvement. First the authors present a parallel between production control and quality organizational structure. They note the duality between control, which is aimed at increasing productivity, and quality, which aims to satisfy the needs of the customer. They also note the hierarchical organizational structure of these two systems of management with, at each level, the notion of a feedback loop. This notion is fundamental to any kind of decision making. The paper is organized around the operational, tactical, and strategic levels, by describing for each level the main methods and tools for control by quality. The overview of these tools and methods starts at the operational level, with the Statistical Process Control, the Taguchi technique, and the "six sigma" approach. On the tactical level, we find a quality system approach, with a documented description of the procedures introduced in the firm. The management system can refer here to Quality Assurance, Total Productive Maintenance, or Management by Total Quality. The formalization through procedures of the rules of decision governing the process control enhances the validity of these rules. This leads to the enhancement of their reliability and to their consolidation. All this counterbalances the human, intrinsically fluctuating, behavior of the control

  17. Demographic controls of future global fire risk

    Knorr, W.; Arneth, A.; Jiang, L.

    2016-08-01

    Wildfires are an important component of terrestrial ecosystem ecology but also a major natural hazard to societies, and their frequency and spatial distribution must be better understood. At a given location, risk from wildfire is associated with the annual fraction of burned area, which is expected to increase in response to climate warming. Until recently, however, only a few global studies of future fire have considered the effects of other important global environmental change factors such as atmospheric CO2 levels and human activities, and how these influence fires in different regions. Here, we contrast the impact of climate change and increasing atmospheric CO2 content on burned area with that of demographic dynamics, using ensembles of climate simulations combined with historical and projected population changes under different socio-economic development pathways for 1901-2100. Historically, humans notably suppressed wildfires. For future scenarios, global burned area will continue to decline under a moderate emissions scenario, except for low population growth and fast urbanization, but start to increase again from around mid-century under high greenhouse gas emissions. Contrary to common perception, we find that human exposure to wildfires increases in the future mainly owing to projected population growth in areas with frequent wildfires, rather than by a general increase in burned area.

  18. Sensometrics for Food Quality Control

    Brockhoff, Per B.

    2011-01-01

    The industrial development of innovative and succesful food items and the measuring of food quality in general is difficult without actually letting human beings evaluate the products using their senses at some point in the process. The use of humans as measurement instruments calls for special...... attention in the modelling and data analysis phase. In this paper the focus is on sensometrics – the „metric“ side of the sensory science field. The sensometrics field is introduced and related to the fields of statistics, chemometrics and psychometrics. Some of the most commonly used sensory testing...

  19. Computer controlled quality of analytical measurements

    Clark, J.P.; Huff, G.A.

    1979-01-01

    A PDP 11/35 computer system is used in evaluating analytical chemistry measurements quality control data at the Barnwell Nuclear Fuel Plant. This computerized measurement quality control system has several features which are not available in manual systems, such as real-time measurement control, computer calculated bias corrections and standard deviation estimates, surveillance applications, evaluaton of measurement system variables, records storage, immediate analyst recertificaton, and the elimination of routine analysis of known bench standards. The effectiveness of the Barnwell computer system has been demonstrated in gathering and assimilating the measurements of over 1100 quality control samples obtained during a recent plant demonstration run. These data were used to determine equaitons for predicting measurement reliability estimates (bias and precision); to evaluate the measurement system; and to provide direction for modification of chemistry methods. The analytical chemistry measurement quality control activities represented 10% of the total analytical chemistry effort

  20. On the quality of global emission inventories. Approaches, methodologies, input data and uncertainties

    Olivier, J.G.J.

    2002-01-01

    Four key scientific questions will be investigated: (1) How does a user define the 'quality' of a global (or national) emission inventory? (Chapter 2); (2) What determines the quality of a global emission inventory? (Chapters 2 and 7); (3) How can inventory quality be achieved in practice and expressed in quantitative terms ('uncertainty')? (Chapters 3 to 6); and (4) What is the preferred approach for compiling a global emission inventory, given the practical limitations and the desired inventory quality? (Chapters 7 and 8)

  1. External Quality Assurance System (EQAS) of the WHO Global Salmonella Surveillance and Laboratory Support Project (Global Salm-Surv) Results from 2001

    Petersen, A.; Aarestrup, Frank Møller; Evans, M.C.

    An international collaborative study on serotyping and antimicrobial susceptibility testing of eight Salmonella enterica strains was performed to enhance the capacity of national and regional reference laboratories in WHO Global Salm-Surv to conduct Salmonella serotyping and antimicrobial suscept...... of the quality control range specified by NCCLS guidelines....

  2. TRAINING SYSTEM OF FUTURE SPECIALISTS: QUALITY CONTROL

    Vladimir A. Romanov

    2015-01-01

    Full Text Available The aim of the investigation is development of innovative strategy of quality control training of engineers and skilled workers (hereinafter – future specialists in educational professional organizations on the principles of social partnership.Methods. Theoretic: theoretic and methodological analysis, polytheoretic synthesis, modeling. Empirical: research and generalization of the system, process and competence – based approaches experience, experiment, observation, surveys, expert evaluation, SWOT-analysis as a method of strategic planning which is to identify the internal and external factors (socio-cultural of the organization surrounding.Results. The strategy of the development of the process of quality control training in educational professional organizations and a predictive model of the system of quality control training for future engineers and workers have been created on the analysis and synthesis of a quantitative specification of the quality, the obtained experience and success in control training of future specialists in educational professional organizations in recent economic and educational conditions.Scientific novelty. There has been built a predicative model of quality control training of future specialists to meet modern standards and the principles of social partnership; the control algorithm of the learning process, developed in accordance with the standards (international of quality ISO in the implementation of the quality control systems of the process approach (matrix-based responsibility, competence and remit of those responsible for the education process in the educational organization, the «problem» terms and diagnostic tools for assessing the quality of professional training of future specialists. The perspective directions of innovation in the control of the quality of future professionals training have been determined; the parameters of a comprehensive analysis of the state of the system to ensure the

  3. Quality control of the documentation process in electronic economic activities

    Krutova A.S.

    2017-06-01

    Full Text Available It is proved that the main tool that will provide adequate information resources e economic activities of social and economic relations are documenting quality control processes as the basis of global information space. Directions problems as formation evaluation information resources in the process of documentation, namely development tools assess the efficiency of the system components – qualitative assessment; development of mathematical modeling tools – quantitative evaluation. A qualitative assessment of electronic documentation of economic activity through exercise performance, efficiency of communication; document management efficiency; effectiveness of flow control operations; relationship management effectiveness. The concept of quality control process documents electronically economic activity to components which include: the level of workflow; forms adequacy of information; consumer quality documents; quality attributes; type of income data; condition monitoring systems; organizational level process documentation; attributes of quality, performance quality consumer; type of management system; type of income data; condition monitoring systems. Grounded components of the control system electronic document subjects of economic activity. Detected components IT-audit management system economic activity: compliance audit; audit of internal control; detailed multilevel analysis; corporate risk assessment methodology. The stages and methods of processing electronic transactions economic activity during condition monitoring of electronic economic activity.

  4. The Impact of Globalization on a Country's Quality of Life: Toward an Integrated Model

    Sirgy, M. Joseph; Lee, Dong-Jin; Miller, Chad; Littlefield, James E.

    2004-01-01

    The purpose of the paper is to develop a set of theoretical propositions to explain the impact of globalization on a country's quality of life (QOL). In this paper, we describe how globalization impacts the quality of life of residents of a country by first articulating the globalization construct (in terms of inflows and outflows of goods,…

  5. CONCRETE STRUCTURES' QUALITY CONTROL IN PRACTICE

    Dolaček-Alduk, Zlata; Blanda, Miroslav

    2011-01-01

    The Croatian civil engineering is characterized by a lack of systematic approach to planning, control and quality assurance in all phases of project realization. The results obtained in establishing the quality management system in some segments of civil engineering production represent initial trends in solving this problem. Benefits are of two types: the achievement of quality for the contractor and obtaining that quaity is being achieved for clients. Execution of concrete structures is a c...

  6. A quality control manual for oral radiology

    Peixoto, J.E.; Ferreira, R.S.; Bessa, S.O.; Domingues, C.; Gomes, C.A.; Oliveira, S.L.G.; Ortiz, J.A.P.

    1988-01-01

    A quality control manual for oral radiology is showed. The X-ray equipment used for this activity is described, such as the X-ray tube, collimator. The high tension in X-ray tube, the spectra, the quality and the quantity of radiation and the X-ray intensity are also analysed. (C.G.C.) [pt

  7. Quality control of gamma radiation measuring systems

    Surma, M.J.

    2002-01-01

    The problem of quality control and assurance of gamma radiation measuring systems has been described in detail. The factors deciding of high quality of radiometric measurements as well as statistical testing and calibration of measuring systems have been presented and discussed

  8. Net analyte signal based statistical quality control

    Skibsted, E.T.S.; Boelens, H.F.M.; Westerhuis, J.A.; Smilde, A.K.; Broad, N.W.; Rees, D.R.; Witte, D.T.

    2005-01-01

    Net analyte signal statistical quality control (NAS-SQC) is a new methodology to perform multivariate product quality monitoring based on the net analyte signal approach. The main advantage of NAS-SQC is that the systematic variation in the product due to the analyte (or property) of interest is

  9. The regulatory maze of quality control

    Stone, T.I.

    1987-01-01

    The appropriateness of specific procedures within a quality control program becomes difficult to assess when an attempt is made to collate all of the available information. This task is discussed from the perspective of the Joint Commission (JCAH Accreditation Manual), HHS(quality assurance program recommendations), equipment manufacturers maintenance schedules, and radiology administrative cost concerns

  10. Quality Control Guidelines for SAM Biotoxin Methods

    Learn more about quality control guidelines and recommendations for the analysis of samples using the pathogen methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  11. Quality Control Guidelines for SAM Radiochemical Methods

    Learn more about quality control guidelines and recommendations for the analysis of samples using the radiochemistry methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  12. Quality Control Guidelines for SAM Pathogen Methods

    Learn more about quality control guidelines and recommendations for the analysis of samples using the biotoxin methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  13. Quality Control Guidelines for SAM Chemical Methods

    Learn more about quality control guidelines and recommendations for the analysis of samples using the chemistry methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  14. Metallographic quality control of welding and brazing

    Slaughter, G.M.

    1979-01-01

    The value of metallography in assuring integrity in the fabrication of metal and components in energy systems is summarized. Metallography also plays an integral role in quality control of welded and brazed joints

  15. Quality Controlled Local Climatological Data (QCLCD) Publication

    National Oceanic and Atmospheric Administration, Department of Commerce — Quality Controlled Local Climatological Data (QCLCD) contains summaries from major airport weather stations that include a daily account of temperature extremes,...

  16. Quality control during construction of power plants

    Hartstern, R.F.

    1982-01-01

    This paper traces the background and examines the necessity for a program to control quality during the construction phase of a power plant. It also attempts to point out considerations for making these programs cost effective

  17. 76 FR 55060 - Aquatic Ecosystems, Water Quality, and Global Change: Challenges of Conducting Multi-Stressor...

    2011-09-06

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9459-7] Aquatic Ecosystems, Water Quality, and Global Change... entitled, Aquatic Ecosystems, Water Quality, and Global Change: Challenges of Conducting Multi- stressor... vulnerability of water quality and aquatic ecosystems across the United States to the potential impacts of...

  18. Back to the future: Rethinking global control of tuberculosis.

    Bloom, Barry R; Atun, Rifat

    2016-03-09

    If the ultimate goal of controlling an infectious disease is to interrupt transmission, the current global tuberculosis strategy is not succeeding. Copyright © 2016, American Association for the Advancement of Science.

  19. Developing methods of controlling quality costs

    Gorbunova A. V.

    2017-01-01

    Full Text Available The article examines issues of managing quality costs, problems of applying economic methods of quality control, implementation of progressive methods of quality costs management in enterprises with the view of improving the efficiency of their evaluation and analysis. With the aim of increasing the effectiveness of the cost management mechanism, authors introduce controlling as a tool of deviation analysis from the standpoint of the process approach. A list of processes and corresponding evaluation criteria in the quality management system of enterprises is introduced. Authors also introduce the method of controlling quality costs and propose it for the practical application, which allows them to determine useful and unnecessary costs at the existing operating plant. Implementing the proposed recommendations in the system of cost management at an enterprise will allow to improve productivity of processes operating and reduce wasted expense on the quality of the process on the basis of determining values of useful and useless costs of quality according to criteria of processes functioning in the system of quality management.

  20. Integrated evolutionary computation neural network quality controller for automated systems

    Patro, S.; Kolarik, W.J. [Texas Tech Univ., Lubbock, TX (United States). Dept. of Industrial Engineering

    1999-06-01

    With increasing competition in the global market, more and more stringent quality standards and specifications are being demands at lower costs. Manufacturing applications of computing power are becoming more common. The application of neural networks to identification and control of dynamic processes has been discussed. The limitations of using neural networks for control purposes has been pointed out and a different technique, evolutionary computation, has been discussed. The results of identifying and controlling an unstable, dynamic process using evolutionary computation methods has been presented. A framework for an integrated system, using both neural networks and evolutionary computation, has been proposed to identify the process and then control the product quality, in a dynamic, multivariable system, in real-time.

  1. It Is About Control: Progressivism, FATCA and Global Law

    Grant Jennifer

    2016-12-01

    Full Text Available Progressive ideology has slowly eroded American principles for over a century, declaring social control its ultimate goal. Social control is not possible while American principles, such as individual freedoms and limited government, thrive. Global control is now the favored progressive tactic to overcome such principles, and no sector of our lives is off limits.

  2. Quality control of commercial bovine lactoferrin.

    Wakabayashi, Hiroyuki; Yamauchi, Koji; Abe, Fumiaki

    2018-06-01

    Herein we review commercial bovine lactoferrin quality issues by describing an example of industrial production, the current status of global quality standardization, and quality-activity concerns for further discussion. Morinaga Milk Industry has been industrially producing bovine lactoferrin in Milei GmbH, Germany, since 1989. We delineate its production and quality as an example of safe and high-quality manufacturing. Currently, global standardization in the quality of bovine lactoferrin is progressing through Novel Food and GRAS in the EU and USA, respectively. Novel Food was applied or notified to seven lactoferrin manufacturers and GRAS was notified to three manufacturers, two of which are for infant use and one is for adult use, by the end of 2017. The specifications of these regulations are relatively high, including more than 95% lactoferrin purity in protein, which means that such companies can supply relatively high-grade lactoferrin. There appear to be several concerns regarding lactoferrin quality affecting activities, including contamination of lipopolysaccharide (LPS) and angiogenin, purity, and degradation of lactoferrin sample. Although LPS is immunologically toxic when invading the body, it is distributed normally in foods and the gut. However, an industrial lactoferrin sample may contain LPS at a maximum LPS/lactoferrin molecule ratio = 1/1724, which means 99.9% of the lactoferrin molecule is LPS-free. It is difficult to speculate that LPS contained in a lactoferrin sample affects its activities. Finally in order to achieve good and reproducible results, we make proposals to researchers a use of high-grade lactoferrin, careful storage, and indication the manufacturers' names and specifications in the paper.

  3. Quality assurance and quality control in mammography: A review

    BenComo, Jose A.

    2000-01-01

    A mammogram is among the most technically demanding radiographic procedures. The early detection of breast cancer relies on the radiologist's ability to perceive subtle changes in the image that are only perceptible with high-quality imaging. Early detection of breast cancer is only as reliable as the mammogram with which a diagnosis is made, and a mammogram is only as accurate as the system that produces it. A quality assurance (QA) program maximizes the likelihood that the mammographic images will provide adequate diagnostic information for the least possible radiation exposure and cost to the patient. The QA program monitors each phase of operation of the imaging facility beginning with the request for an examination and ending with the interpretation of the referring physician and ensures that the imaging equipment used for the examination will yield the information desired. Because image quality is the most important technical aspect of mammography, this review summarizes the most important QA and quality control issues

  4. Quality control and analysis of radiotracer compounds

    Sheppard, G.; Thomson, R.

    1977-01-01

    Special emphasis was on the problems and errors possible in quality control and analysis. The principles underlying quality control were outlined, and analytical techniques applicable to radiotracers were described. Chapter concluded with a selection of examples showing the effects of impurities on the use of radiotracers. The subject of quality control and analysis was treated from the viewpoint of the user and those research workers who need to synthesize and analyze their own radiochemicals. The quality characteristics for radiotracers are of two kinds, valuable or attributive. These were discussed in the chapter. For counting low radioactive concentration, scintillation techniques are in general use, whereas ionization techniques are now used mainly for the measurement of high radioactive concentrations or large quantities of radioactivity, for scanning chromatograms, and a number of very specific purposes. Determination of radionuclidic purity was discussed. Use of radiotracers in pharmaceuticals were presented. 4 figures, 6 tables

  5. 20. Quality assurance and quality control in nuclear medicine

    Vavrejn, B.

    1989-01-01

    Quality control principles to be applied when taking over and using nuclear medicine instrumentation are given. Such instrumentation includes activity meters, gamma detectors for in vitro measurements (manual or automated instruments), gamma detectors for in vivo measurements (with one or several probes), 'movable' scintigraphs and 'steady' scintigraphs (gamma cameras). (Z.S.)

  6. What controls deuterium excess in global precipitation?

    S. Pfahl

    2014-04-01

    Full Text Available The deuterium excess (d of precipitation is widely used in the reconstruction of past climatic changes from ice cores. However, its most common interpretation as moisture source temperature cannot directly be inferred from present-day water isotope observations. Here, we use a new empirical relation between d and near-surface relative humidity (RH together with reanalysis data to globally predict d of surface evaporation from the ocean. The very good quantitative agreement of the predicted hemispherically averaged seasonal cycle with observed d in precipitation indicates that moisture source relative humidity, and not sea surface temperature, is the main driver of d variability on seasonal timescales. Furthermore, we review arguments for an interpretation of long-term palaeoclimatic d changes in terms of moisture source temperature, and we conclude that there remains no sufficient evidence that would justify to neglect the influence of RH on such palaeoclimatic d variations. Hence, we suggest that either the interpretation of d variations in palaeorecords should be adapted to reflect climatic influences on RH during evaporation, in particular atmospheric circulation changes, or new arguments for an interpretation in terms of moisture source temperature will have to be provided based on future research.

  7. CDC Grand Rounds: global tobacco control.

    Asma, Samira; Song, Yang; Cohen, Joanna; Eriksen, Michael; Pechacek, Terry; Cohen, Nicole; Iskander, John

    2014-04-04

    During the 20th century, use of tobacco products contributed to the deaths of 100 million persons worldwide. In 2011, approximately 6 million additional deaths were linked to tobacco use, the world's leading underlying cause of death, responsible for more deaths each year than human immunodeficiency virus/acquired immunodeficiency syndrome (HIV/AIDS), tuberculosis, and malaria combined. One third to one half of lifetime users die from tobacco products, and smokers die an average of 14 years earlier than nonsmokers. Manufactured cigarettes account for 96% of all tobacco sales worldwide. From 1880 to 2009, annual global consumption of cigarettes increased from an estimated 10 billion cigarettes to approximately 5.9 trillion cigarettes, with five countries accounting for 58% of the total consumption: China (38%), Russia (7%), the United States (5%), Indonesia (4%), and Japan (4%). Among the estimated 1 billion smokers worldwide, men outnumber women by four to one. In 14 countries, at least 50% of men smoke, whereas in more than half of these same countries, fewer than 10% of women smoke. If current trends persist, an estimated 500 million persons alive today will die from use of tobacco products. By 2030, tobacco use will result in the deaths of approximately 8 million persons worldwide each year. Yet, every death from tobacco products is preventable.

  8. The Global View on Port State Control

    S. Knapp (Sabine); Ph.H.B.F. Franses (Philip Hans)

    2006-01-01

    textabstractThis report is the second part of a PhD project entitled "The Econometrics of Maritime Safety – Recommendations to Enhance Safety at Sea" which is based on 183,000 port state control inspections and 11,700 casualties from various data sources. Its overall objective is to provide

  9. Quality control in 99m technetium radiopharmaceuticals

    Leon Cabana, Alba

    1994-01-01

    This work means about the quality control in Tc radiopharmaceuticals preparation at hospitalary levels. Several steps must be used in a Nuclear Medicine Laboratory, such as proceeding,radiopharmaceuticals kits preparation, and dispensation materials,glasses,stopper,physical aspects,identification,ph control,storage,and reactif kits

  10. PACS quality control and automatic problem notifier

    Honeyman-Buck, Janice C.; Jones, Douglas; Frost, Meryll M.; Staab, Edward V.

    1997-05-01

    One side effect of installing a clinical PACS Is that users become dependent upon the technology and in some cases it can be very difficult to revert back to a film based system if components fail. The nature of system failures range from slow deterioration of function as seen in the loss of monitor luminance through sudden catastrophic loss of the entire PACS networks. This paper describes the quality control procedures in place at the University of Florida and the automatic notification system that alerts PACS personnel when a failure has happened or is anticipated. The goal is to recover from a failure with a minimum of downtime and no data loss. Routine quality control is practiced on all aspects of PACS, from acquisition, through network routing, through display, and including archiving. Whenever possible, the system components perform self and between platform checks for active processes, file system status, errors in log files, and system uptime. When an error is detected or a exception occurs, an automatic page is sent to a pager with a diagnostic code. Documentation on each code, trouble shooting procedures, and repairs are kept on an intranet server accessible only to people involved in maintaining the PACS. In addition to the automatic paging system for error conditions, acquisition is assured by an automatic fax report sent on a daily basis to all technologists acquiring PACS images to be used as a cross check that all studies are archived prior to being removed from the acquisition systems. Daily quality control is preformed to assure that studies can be moved from each acquisition and contrast adjustment. The results of selected quality control reports will be presented. The intranet documentation server will be described with the automatic pager system. Monitor quality control reports will be described and the cost of quality control will be quantified. As PACS is accepted as a clinical tool, the same standards of quality control must be established

  11. Exposure parameters in fluoroscopy equipment. Quality control

    Alonso, M.; Castaneda, M.J.; Matorras, P.; Diaz-Caneja, N.; Gutierrez, I.

    1992-01-01

    Within the quality control program in Diagnostic Radiology currently being undertaken at the 'Marques de Valdecilla' University Hospital, the corresponding specification and procedure prototypes for the control of conventional radioscopy equipment have been elaborated and applied. This paper presents the values proposed in the specifications and those obtained for the following radioscopy equipment parameters: reference kerma, and its reproducibility, kerma linearity, maximum kerma at the skin, and total filtration. The results obtained indicate that the equipment studied could comply with specified requirements if a Maintenance Program were to be implemented in coordination with the Quality Control Program. (author)

  12. Development of the gaharu oil quality control

    Chong Saw Peng; Mohd Fajri Osman; Shyful Azizi Abdul Rahman; Khairuddin Abdul Rahim; Mat Rasol Awang

    2010-01-01

    Gaharu (Agar wood) is a secondary metabolite produces by the Aquilaria spp. and accumulates in the plant cell in oleoresin form. The essential oil known as gaharu oil can be extracted from this oleoresin gaharu via varies extraction method such as the water distillation, solvent extraction, pressurize extraction and etc. The gaharu oil extracted through different methods will give different fragrances. Besides, different source of materials will also give different in chemical profiles. In gaharu oil trading market, most of the buyers request quality assurance from the gaharu oil manufacturer to assure the gaharu oil purchased meets their standard requirement. Since there is a demand on gaharu oil quality assurance then it become a need to develop the gaharu oil quality control method in order to have a standard quality control of gaharu oil presented in a certificate of analysis and verified by laboratory. (author)

  13. Quality control in diagnostic radiology - patient dosimetry

    Prlic, I; Radalj, Z; Brumen, V; Cerovac, H [Institute for Medical Research and Occupational Health, Laboratory for Radiation Protection and Dosimetry, Zagreb (Croatia); Gladic, J [Institute for Physics, Laboratory for Solid State Physics, Zagreb (Croatia); Tercek, V [Clinical Hospital Sisters of Mercy, Health Physics Department, Zagreb (Croatia)

    1997-12-31

    In order to establish the Quality Criteria for diagnostic radiographic images in the radiology departments in Republic of Croatia we have started the several Quality Control projects on the field. The measurements are performed according to some methodology recommendations in our law but the methodology, measurement principles, measurement equipment, phantoms, measurable parameters for the good use by radiographers, statistical and numerical evaluation, dosimetric philosophy etc. where first recognized as a private/or group hazard of each person involved in the procedure of evaluation of diagnostic radiology images/diagnosis. The important quality elements of the imaging process are: the diagnostic quality of the radiographic image, the radiation dose to the patient and the choice of the radiographic technique. This depends on the x-ray unit (tube) radiation quality, image processing quality and final image evaluation quality. In this paper we will show how the Quality Control measurements can be easily connected to the dose delivered to the patient for the known diagnostic procedure and how this can be used by radiographers in their daily work. The reproducibility of the x-ray generator was checked before the service calibration and after the service calibration. The table of kV dependence and output dose per mAs was calculated and the ESD (entrance surface dose) was measured/calculated for the specific diagnostic procedure. After the phantom calculation were made and the dose prediction for the given procedure was done, measurements were done on the patients (digital dosemeters, TLD and film dosemeter combinations). We are claiming that there is no need to measure each patient if the proper Quality Control measurements are done and the proper table of ESD for each particular x-ray tube in diagnostic departments is calculated for the radiographers daily use. (author). 1 example, 1 fig., 13 refs.

  14. Quality control in paediatric nuclear medicine

    Fischer, S.; Hahn, K.

    1997-01-01

    Nuclear medicine examinations in children require a maximum in quality. This is true for the preparation of the child and parents, the imaging procedure, processing and documentation. It is necessary that quality control through all steps is performed regularly. The aim must be that the children receive a minimum radiation dose, while there needs to be a high quality in imaging and clinical information from the study. Furthermore the child should not be too much psychologically affected by the nuclear medicine examination. (orig.) [de

  15. Quality Assurance and Quality Control in TLD Measurement

    Bhuiyan, S.I.; Qronfla, M.M.; Abulfaraj, W.H.; Kinsara, A.A.; Taha, T.M.; Molla, N.I.; Elmohr, S.M.

    2008-01-01

    TLD technique characterized by high precision and reproducibility of dose measurement is presented by addressing pre-readout annealing, group sorting, dose evaluation, blind tests, internal dose quality audit and external quality control audits. Two hundred and forty TLD chips were annealed for 1 hour at 4000 degree C followed by 2 h at 1000 degree C. After exposure of 1 mGy from 90 Sr irradiator TLDs were subjected to pre-readout annealing at 1000 degree C, then readout, sorted into groups each with nearly equal sensitivity. Upon repeating the procedures, TLDs having response >3.5% from group mean were dropped to assuring group stability. Effect of pre-readout annealing has been studied. Series of repeated measurements were conducted to stabilize calibration procedures and DCF generation using SSDL level 137 Cs calibrator, dose master, ionization chambers. Performed internal dose quality audits, blind tests and validated by external QC tests with King Abdulaziz City of Science and Technology

  16. Frontiers in statistical quality control 11

    Schmid, Wolfgang

    2015-01-01

    The main focus of this edited volume is on three major areas of statistical quality control: statistical process control (SPC), acceptance sampling and design of experiments. The majority of the papers deal with statistical process control, while acceptance sampling and design of experiments are also treated to a lesser extent. The book is organized into four thematic parts, with Part I addressing statistical process control. Part II is devoted to acceptance sampling. Part III covers the design of experiments, while Part IV discusses related fields. The twenty-three papers in this volume stem from The 11th International Workshop on Intelligent Statistical Quality Control, which was held in Sydney, Australia from August 20 to August 23, 2013. The event was hosted by Professor Ross Sparks, CSIRO Mathematics, Informatics and Statistics, North Ryde, Australia and was jointly organized by Professors S. Knoth, W. Schmid and Ross Sparks. The papers presented here were carefully selected and reviewed by the scientifi...

  17. Quality Assurance and Control in Laboratory using Neutron Activation Analysis

    Chung, Y. S.; Moon, J. H.; Sun, G. M.; Kim, S. H.; Baek, S. Y.; Lim, J. M.; Kim, H. R

    2007-01-15

    In accordance with the increment of international trade associated with the worldwide globalization, the importance of quality assurance and control for the commodity produced from one's own country has been stressed. ISO (International Organization for Standards) defines quality control as 'the operational techniques and activities that are used to fulfill the requirements for quality'. Since 1996, the HANARO research reactor in the Korea Atomic Energy Research Institute has been operated thereafter initial critical operation on April 1995. Neutron activation analysis system and applied techniques which is one of a nuclear analytical technologies using reactor neutrons has been developed for user's supporting and the establishment of the quality system for a measurement and analysis, testing and inspection was implemented successfully. On the basis of the qualified NAA system, the test and measurement of more than 1500 samples which is requested from 30 organizations including industrial companies, universities and institutes carried out in NAA laboratory annually. Moreover, as the goal of mutual recognition agreement (MRA) which can be removed a technical barrier in international trade, the objectivity and the confidence of analytical quality in NAA laboratory became established through the installation of international accreditation system by implementing analytical quality system in accordance with international standards in 2001. The aim of the report was to summarize the technical management of introduction, methods and the results for a quality control and assurance which should be performed in NAA technique using the HANARO research reactor. The report will help building up effective quality control strategy in the future.

  18. Quality control procedures in positron tomography

    Spinks, T.; Jones, T.; Heather, J.; Gilardi, M.

    1989-01-01

    The derivation of physiological parameters in positron tomography relies on accurate calibration of the tomograph. Normally, the calibration relates image pixel count density to the count rate from an external blood counter per unit activity concentration in each device. The quality control of the latter is simple and relies on detector stability assessed by measurement of a standard source of similar geometry to a blood sample. The quality control of the tomographic data depends on (i) detector stability, (ii) uniformity of calibration and normalisation sources and (iii) reproducibility of the attenuation correction procedure. A quality control procedure has been developed for an 8 detector ring (15 transaxial plane) tomograph in which detector response is assessed by acquiring data from retractable transmission ring sources. These are scanned daily and a print out of detector efficiencies is produced as well as changes from a given data. This provides the raw data from which decisions on recalibration or renormalisation are made. (orig.)

  19. Quality control of the activity meter

    Rodrigues, Marlon da Silva Brandão; Sá, Lídia Vasconcelos de

    2017-01-01

    Objective: To carry out a comparative analysis of national and international standards regarding the quality control of the activity meter used in Nuclear Medicine Services in Brazil. Material and methods: Quality control protocols from the International Atomic Energy Agency (IAEA), American Association of Physicists in Medicine (AAPM) and International Electrotechnical Commission (IEC) were pointed out and compared with requirements from both regulatory Brazilian agencies, National Surveillance Agency (ANVISA) and National Nuclear Energy Commission (CNEN). Results: The daily routine tests recommended by the regulatory agencies do not have significant differences; in contrast the tests with higher periodicities like (accuracy, linearity and precision) have differences discrepant. Conclusion: In view of the comparative analysis carried out, it is suggested that the national recommendations for the quality control tests of the activity meter should be checked and evaluated, with emphasis on the semiannual and annual periodicity tests. (author)

  20. Quality control of 11C-carfentanil

    Zhang Xiaojun; Zhang Jinming; Tian Jiahe; Xiang Xiaohui

    2013-01-01

    To study the quality control of 11 C-Carfentanil injection, physical, chemical and biological identification were used. The chemical and radiochemical purity of 11 C-Carfentanil Injection were detected by HPLC and Flower Count system; measured the quantity of product by LC-MS, specific activity was calculated later; The PTS was used to detect endotoxin, and other quality control methods were put up to guarantee the security of its clinical application. The produce appeared colorless and transparent, the radiochemical purity was more than 98%, content of the endotoxin was less than 5 EU/mL. The result showed that 11 C-Carfentanil injection had fulfilled pharmaceutical quality control request and could be applied safely to animal experiment and clinical diagnosis. (authors)

  1. Protein quality control in the nucleus

    Nielsen, Sofie V.; Poulsen, Esben Guldahl; Rebula, Caio A.

    2014-01-01

    to aggregate, cells have evolved several elaborate quality control systems to deal with these potentially toxic proteins. First, various molecular chaperones will seize the misfolded protein and either attempt to refold the protein or target it for degradation via the ubiquitin-proteasome system...... to be particularly active in protein quality control. Thus, specific ubiquitin-protein ligases located in the nucleus, target not only misfolded nuclear proteins, but also various misfolded cytosolic proteins which are transported to the nucleus prior to their degradation. In comparison, much less is known about...... these mechanisms in mammalian cells. Here we highlight recent advances in our understanding of nuclear protein quality control, in particular regarding substrate recognition and proteasomal degradation....

  2. Negotiating a regime to control global warming

    Sebenius, J.K.

    1991-01-01

    For purposes of analysis, this paper has uncritically maintained that the prospect of a serious climate problem exists and has only lightly examined the broader advantages and drawbacks of various proposed policy and institutional responses. Crucial as they are to a full treatment of the issues, these underlying substantive and policy questions enter the analysis primarily insofar as they affect the likely outcomes of pending and potential negotiations. To an advocate of a new greenhouse control regime, the fundamental negotiating task is to craft and sustain a meaningful winning coalition of countries backing such a regime. Two centrally necessary conditions for the fundamental task are: (1) that each member of the coalition see enough gain in the regime relative to the alternatives to adhere and (2) the potential and actual blocking coalitions of interests opposed to the regime be prevented from forming and from being acceptably accommodated or otherwise neutralized. The analysis of this paper is organized around key questions whose answers will influence whether and how these two necessary conditions might (or might not) be met

  3. The Study on quality control of nuclear power installation project

    Wu Jie

    2008-01-01

    The quality planning, quality assurance and quality control are discussed by applying the quality control (QC) theory and combining the real situation of the Qinshan II project. This paper is practical and plays an active role in instruction of project quality control by applying the above QC theory and control techniques. (authors)

  4. A quality control program for radiation sources

    Almeida, C.E. de; Sibata, C.H.; Cecatti, E.R.; Kawakami, N.S.; Alexandre, A.C.; Chiavegatti Junior, M.

    1982-01-01

    An extensive quality control program was established covering the following areas: physical parameters of the therapeutical machines, dosimetric standards, preventive maintenance of radiation sources and measuring instruments. A critical evaluation of this program was done after two years (1977-1979) of routine application and the results will be presented. The fluctuation on physical parameters strongly supports the efforts and cost of a quality control program. This program has certainly improved the accuracy required on the delivery of the prescribed dose for radiotherapy treatment. (Author) [pt

  5. Quality control of nuclear medicine instruments 1991

    1991-05-01

    This document gives detailed guidance on the quality control of various instruments used in nuclear medicine. A first preliminary document was drawn up in 1979. A revised and extended version, incorporating recommended procedures, test schedules and protocols was prepared in 1982. The first edition of ''Quality Control of Nuclear Medicine Instruments'', IAEA-TECDOC-317, was printed in late 1984. Recent advances in the field of nuclear medicine imaging made it necessary to add a chapter on Camera-Computer Systems and another on SPECT Systems. Figs and tabs

  6. Quality control of nuclear medicine instruments, 1991

    1996-12-01

    This document gives detailed guidance on the quality control of various instruments used in nuclear medicine. A first preliminary document was drawn up in 1979. A revised and extended version, incorporating recommended procedures, test schedules and protocols was prepared in 1982. The first edition of 'Quality Control of Nuclear Medicine Instruments', IAEA-TECDOC-317, was printed in late 1984. Recent advances in the field of nuclear medicine imaging made it necessary to add a chapter on Camera-Computer Systems and another on SPECT Systems

  7. HPLC for quality control of polyimides

    Young, P. R.; Sykes, G. F.

    1979-01-01

    High Pressure Liquid Chromatography (HPLC) as a quality control tool for polyimide resins and prepregs are presented. A data base to help establish accept/reject criteria for these materials was developed. This work is intended to supplement, not replace, standard quality control tests normally conducted on incoming resins and prepregs. To help achieve these objectives, the HPLC separation of LARC-160 polyimide precursor resin was characterized. Room temperature resin aging effects were studied. Graphite reinforced composites made from fresh and aged resin were fabricated and tested to determine if changes observed by HPLC were significant.

  8. Statistical quality control a loss minimization approach

    Trietsch, Dan

    1999-01-01

    While many books on quality espouse the Taguchi loss function, they do not examine its impact on statistical quality control (SQC). But using the Taguchi loss function sheds new light on questions relating to SQC and calls for some changes. This book covers SQC in a way that conforms with the need to minimize loss. Subjects often not covered elsewhere include: (i) measurements, (ii) determining how many points to sample to obtain reliable control charts (for which purpose a new graphic tool, diffidence charts, is introduced), (iii) the connection between process capability and tolerances, (iv)

  9. Technical quality control - constancy controls for digital mammography systems

    Pedersen, K.; Landmark, I.D.; Bredholt, K.; Hauge, I.H.R.

    2009-04-01

    To ensure the quality of mammographic images, so-called constancy control tests are performed frequently. The report contains a programme for constancy control of digital mammography systems, encompassing the mammography unit, computed radiography (CR) systems, viewing conditions and displays, printers, and procedures for data collection for patient dose calculations. (Author)

  10. Control cards as a statistical quality control resource

    Aleksandar Živan Drenovac

    2013-02-01

    Full Text Available Normal 0 false false false MicrosoftInternetExplorer4 This paper proves that applying of statistical methods can significantly contribute increasing of products and services quality, as well as increasing of institutions rating. Determining of optimal, apropos anticipatory and limitary values, is based on sample`s statistical analyze. Control cards represent very confident instrument, which is simple for use and efficient for control of process, by which process is maintained in set borders. Thus, control cards can be applied in quality control of procesess of weapons and military equipment production, maintenance of technical systems, as well as for seting of standards and increasing of quality level for many other activities.

  11. A Comparison of Power Quality Controllers

    Petr Černek

    2012-01-01

    Full Text Available This paper focuses on certain types of FACTS (Flexibile AC Transmission System controllers, which can be used for improving the power quality at the point of connection with the power network. It focuses on types of controllers that are suitable for use in large buildings, rather than in transmission networks. The goal is to compare the features of the controllers in specific tasks, and to clarify which solution is best for a specific purpose. It is in some cases better and cheaper to use a combination of controllers than a single controller. The paper also presents the features of a shunt active harmonic compensator, which is a very modern power quality controller that can be used in many cases, or in combination with other controllers. The comparison was made using a matrix diagram that, resulted from mind mapsand other analysis tools. The paper should help engineers to choose the best solution for improving the power quality in a specific power network at distribution level.

  12. Co-benefits of global and regional greenhouse gas mitigation for US air quality in 2050

    Zhang, Yuqiang; Bowden, Jared H.; Adelman, Zachariah; Naik, Vaishali; Horowitz, Larry W.; Smith, Steven J.; West, J. Jason

    2016-08-01

    (76 % of the total) than that from domestic GHG mitigation only (24 %), highlighting the importance of global methane reductions and the intercontinental transport of air pollutants. For PM2.5, the benefits of domestic GHG control are greater (74 % of total). Since foreign contributions to co-benefits can be substantial, with foreign O3 benefits much larger than those from domestic reductions, previous studies that focus on local or regional co-benefits may greatly underestimate the total co-benefits of global GHG reductions. We conclude that the US can gain significantly greater domestic air quality co-benefits by engaging with other nations to control GHGs.

  13. Potential Air Quality Impacts of Global Bioenergy Crop Cultivation

    Porter, W. C.; Rosenstiel, T. N.; Barsanti, K. C.

    2012-12-01

    The use of bioenergy crops as a replacement for traditional coal-powered electricity generation will require large-scale land-use change, and the resulting changes in emissions of biogenic volatile organic compounds (BVOCs) may have negative impacts on local to regional air quality. BVOCs contribute to the formation of both ozone (O3) and fine particulate matter (PM2.5), with magnitudes of specific compound emissions governed largely by plant speciation and land coverage. For this reason, large-scale land-use change has the potential to markedly alter regional O3 and PM2.5 levels, especially if there are large differences between the emission profiles of the replacement bioenergy crops (many of which are high BVOC emitters) and the previous crops or land cover. In this work, replacement areas suitable for the cultivation of the bioenergy crops switchgrass (Panicum virgatum) and giant reed (Arundo donax) were selected based on existing global inventories of under-utilized cropland and local climatological conditions. These two crops are among the most popular current candidates for bioenergy production, and provide contrasting examples of energy densities and emissions profiles. While giant reed has been selected in an ongoing large-scale coal-to-biocharcoal conversion in the Northwestern United States due to its high crop yields and energy density, it is also among the highest biogenic emitters of isoprene. On the other hand, switchgrass produces less biomass per acre, but also emits essentially no isoprene and low total BVOCs. The effects of large-scale conversion to these crops on O3 and PM2.5 were simulated using version 1.1 of the Community Earth System Model (CESM) coupled with version 2.1 of the Model of Emissions of Gases and Aerosols from Nature (MEGAN). By comparing crop replacement scenarios involving A. donax and P. virgatum, the sensitivities of O3 and PM2.5 levels to worldwide increases in bioenergy production were examined, providing an initial

  14. Tobacco control, global health policy and development: towards policy coherence in global governance

    Collin, Jeff

    2015-01-01

    The WHO Framework Convention on Tobacco Control (FCTC) demonstrates the international political will invested in combating the tobacco pandemic and a newfound prominence for tobacco control within the global health agenda. However, major difficulties exist in managing conflicts with foreign and trade policy priorities, and significant obstacles confront efforts to create synergies with development policy and avoid tensions with other health priorities. This paper uses the concept of policy coherence to explore congruence and inconsistencies in objectives, policy, and practice between tobacco control and trade, development and global health priorities. Following the inability of the FCTC negotiations to satisfactorily address the relationship between trade and health, several disputes highlight the challenges posed to tobacco control policies by multilateral and bilateral agreements. While the work of the World Bank has demonstrated the potential contribution of tobacco control to development, the absence of non-communicable diseases from the Millennium Development Goals has limited scope to offer developing countries support for FCTC implementation. Even within international health, tobacco control priorities may be hard to reconcile with other agendas. The paper concludes by discussing the extent to which tobacco control has been pursued via a model of governance very deliberately different from those used in other health issues, in what can be termed ‘tobacco exceptionalism’. The analysis developed here suggests that non-communicable disease (NCD) policies, global health, development and tobacco control would have much to gain from re-examining this presumption of difference. PMID:22345267

  15. Data Organization for Quality Control Test

    Yahaya Talib; Glam Hadzir Patai Mohamad; Wan Hamirul Bahrin Wan Kamal

    2011-01-01

    Test data and results for quality control of Mo-99/ Tc-99m generator shall be organized properly. A computer program was developed using Visual Basic 6.0 to process test data, store data and results to specific folder, generate test reports and certificates. Its performance has been evaluated and tested. (author)

  16. Water quality control program in experimental circuits

    Cegalla, Miriam A.

    1996-01-01

    The Water Quality Control Program of the Experimental Circuits visualizes studying the water chemistry of the cooling in the primary and secondary circuits, monitoring the corrosion of the systems and studying the mechanism of the corrosion products transport in the systems. (author)

  17. Studies of quality control procedures for radiopharmaceuticals

    Zivanovic, M.; Trott, N.G.

    1983-01-01

    In this paper, a short description is given of a radiopharmaceutical preparation suite set up at the Royal Marsden Hospital and an account is presented of methods used for quality control of radiopharmaceuticals and of the results obtained over a period of about two and a half years

  18. Materials, methods and quality control, ch. 3

    Vader, H.L.

    1978-01-01

    A description of the chemical reagents, the 125 I-labelled angiotensin I, the antiserum and the standards is given. A modified measuring method with the New England Nuclear kit for angiotensin I radioimmunoassay is presented as well as the quality control data

  19. Guidelines for radriopharmaceutical quality control in hospitals

    Welsh, W.J.

    1982-01-01

    This document has been prepared to assist hospital administrators in ensuring that adequate quality control is performed on radiopharmaceuticals administered to their patients. Three sets of guidelines are presented, the degree of sophistication being dependent on the amount of hospital involvement in the radiopharmaceutical preparation

  20. Quality Control Of Selected Pesticides With GC

    Karasali, H. [Benaki Phytopathological Institute Laboratory of Physical and Chemical Analysis of Pesticides, Ekalis (Greece)

    2009-07-15

    The practical quality control of selected pesticides with GC is treated. Detailed descriptions are given on materials and methods used, including sample preparation and GC operating conditions. The systematic validation of multi methods is described, comprising performance characteristics in routine analysis, like selectivity, specificity etc. This is illustrated by chromatograms, calibration curves and tables derived from real laboratory data. (author)

  1. Outsourcing University Degrees: Implications for Quality Control

    Edwards, Julie; Crosling, Glenda; Edwards, Ron

    2010-01-01

    Education institutions worldwide have and continue to seek opportunities to spread their offerings abroad. While the provision of courses to students located overseas through partner institutions has many advantages, it raises questions about quality control that are not as applicable to other forms of international education. This paper uses a…

  2. Assessment of global phase uncertainty in case-control studies

    van Houwelingen Hans C

    2009-09-01

    Full Text Available Abstract Background In haplotype-based candidate gene studies a problem is that the genotype data are unphased, which results in haplotype ambiguity. The measure 1 quantifies haplotype predictability from genotype data. It is computed for each individual haplotype, and for a measure of global relative efficiency a minimum value is suggested. Alternatively, we developed methods directly based on the information content of haplotype frequency estimates to obtain global relative efficiency measures: and based on A- and D-optimality, respectively. All three methods are designed for single populations; they can be applied in cases only, controls only or the whole data. Therefore they are not necessarily optimal for haplotype testing in case-control studies. Results A new global relative efficiency measure was derived to maximize power of a simple test statistic that compares haplotype frequencies in cases and controls. Application to real data showed that our proposed method gave a clear and summarizing measure for the case-control study conducted. Additionally this measure might be used for selection of individuals, who have the highest potential for improving power by resolving phase ambiguity. Conclusion Instead of using relative efficiency measure for cases only, controls only or their combined data, we link uncertainty measure to case-control studies directly. Hence, our global efficiency measure might be useful to assess whether data are informative or have enough power for estimation of a specific haplotype risk.

  3. Global Scenarios of Air Pollution until 2030: Combining Air Quality, Climate Change and Energy Access Policies

    Rao, S.; Dentener, F. J.; Klimont, Z.; Riahi, K.

    2011-12-01

    Outdoor air pollution is increasingly recognized as a significant contributor to global health outcomes. This has led to the implementation of a number of air quality policies worldwide, with total air pollution control costs in 2005 estimated at US$195 billion. More than 80% of the world's population is still found to be exposed to PM2.5 concentrations exceeding WHO air quality guidelines and health impacts resulting from these exposures estimated at around 2-5% of the global disease burden. Key questions to answer are 1) How will pollutant emissions evolve in the future given developments in the energy system and how will energy and environmental policies influence such emission trends. 2) What implications will this have for resulting exposures and related health outcomes. In order to answer these questions, varying levels of stringency of air quality legislation are analyzed in combination with policies on universal access to clean cooking fuels and limiting global temperature change to 2°C in 2100. Bottom-up methodologies using energy emissions modeling are used to derive sector-based pollutant emission trajectories until 2030. Emissions are spatially downscaled and used in combination with a global transport chemistry model to derive ambient concentrations of PM2.5. Health impacts of these exposures are further estimated consistent with WHO data and methodology. The results indicate that currently planned air quality legislation combined with rising energy demand will be insufficient in controlling future emissions growth in developing countries. In order to achieve significant reductions in pollutant emissions of the order of more than 50% from 2005 levels and reduce exposures to levels consistent with WHO standards, it will be necessary to increase the stringency of such legislations and combine them with policies on energy access and climate change. Combined policies also result in reductions in air pollution control costs as compared to those associated

  4. Global trends in milk quality: implications for the irish dairy industry

    More SJ

    2009-04-01

    Full Text Available Abstract The quality of Irish agricultural product will become increasingly important with the ongoing liberalisation of international trade. This paper presents a review of the global and Irish dairy industries; considers the impact of milk quality on farm profitability, food processing and human health, examines global trends in quality; and explores several models that are successfully being used to tackle milk quality concerns. There is a growing global demand for dairy products, fuelled in part by growing consumer wealth in developing countries. Global dairy trade represents only 6.2% of global production and demand currently outstrips supply. Although the Irish dairy industry is small by global standards, approximately 85% of annual production is exported annually. It is also the world's largest producer of powdered infant formula. Milk quality has an impact on human health, milk processing and on-farm profitability. Somatic cell count (SCC is a key measure of milk quality, with a SCC not exceeding 400,000 cells/ml (the EU milk quality standard generally accepted as the international export standard. There have been ongoing improvements in milk quality among both established and emerging international suppliers. A number of countries have developed successful industry-led models to tackle milk quality concerns. Based on international experiences, it is likely that problems with effective translation of knowledge to practice, rather than incomplete knowledge per se, are the more important constraints to national progress towards improved milk quality.

  5. The role and relevance of quality assurance to quality control

    Churchill, G.F.

    1989-01-01

    The paper describes the development of Quality Assurance as a total management technique, incorporating manufacturing and construction Quality Control, to give confidence of satisfactory in-service performance. The application of QA to the Heysham 2 and Torness AGR projects design and construction is defined with particular reference to the development of a QA requirements specification, delegation of QA responsibility through the hierarchy of purchasers and suppliers of plant and material, the role of the QA organization and QA auditing. The paper discusses the effectiveness and benefits of QA and the problems identified in its application and implementation. The problems, their solutions and longer term improvements to reduce the costs of QA as well as enhancing confidence in the satisfactory performance of future nuclear projects, are described. (author)

  6. Quality control of PET/CT

    Angelova, J.; Zajcharov, M.

    2013-01-01

    Full text: Introduction: The aim of this work is to undertake a review of the methods for checking and adjusting the computer and positron emission tomography in the Hospital 'Alexandrovska' by the attached to the equipment phantoms according to the manufacturer prescription in order to fulfill its requirements for the entry of the main parameters image within certain limits. Materials and Methods: At the start of work a check of the lasers setting for patient positioning and 'heat' of the X-ray tube scanner to better image quality were made. Daily verification procedures on the image quality of CT through the water phantom and weekly - 'air' calibration were carried out. In positron part, daily control involves setting the resolution and sensitivity of the scanner through built Ga68 phantom. When commissioning, after repair and at least once a year, it is necessary to verify the accuracy of registration of the pulses from the crystal with a water phantom of known volume and the coincidence between CT and PET image. Results: The process of quality control is interactive. The results are displayed in tables and graphically, with the goal the individual values to fall within the determined by manufacturers range and to meet the standards for image quality. If necessary, the procedure repeats several times until it is fulfilled. Conclusion: Ensuring the quality of the image in positron emission tomography combined with computed tomography, is inextricably linked to accurate and precise diagnosis of tumor processes in the human body

  7. Quality assurance and quality control of nuclear engineering during construction phase

    Zhang Zhihua; Deng Yue; Liu Yaoguang; Xu Xianqi; Zhou Shan; Qian Dazhi; Zhang Yang

    2007-01-01

    The quality assurance (QA) and quality control (QC) is a very important work in the nuclear engineering. This paper starts with how to establish quality assurance system of nuclear engineering construction phase, then introduces several experiments and techniques such as the implementation of quality assurance program, the quality assurance and quality control of contractors, the quality surveillance and control of supervisory companies, quality assurance audit and surveillance of builders. (authors)

  8. Internal quality control: planning and implementation strategies.

    Westgard, James O

    2003-11-01

    The first essential in setting up internal quality control (IQC) of a test procedure in the clinical laboratory is to select the proper IQC procedure to implement, i.e. choosing the statistical criteria or control rules, and the number of control measurements, according to the quality required for the test and the observed performance of the method. Then the right IQC procedure must be properly implemented. This review focuses on strategies for planning and implementing IQC procedures in order to improve the quality of the IQC. A quantitative planning process is described that can be implemented with graphical tools such as power function or critical-error graphs and charts of operating specifications. Finally, a total QC strategy is formulated to minimize cost and maximize quality. A general strategy for IQC implementation is recommended that employs a three-stage design in which the first stage provides high error detection, the second stage low false rejection and the third stage prescribes the length of the analytical run, making use of an algorithm involving the average of normal patients' data.

  9. Quality and Control of Water Vapor Winds

    Jedlovec, Gary J.; Atkinson, Robert J.

    1996-01-01

    Water vapor imagery from the geostationary satellites such as GOES, Meteosat, and GMS provides synoptic views of dynamical events on a continual basis. Because the imagery represents a non-linear combination of mid- and upper-tropospheric thermodynamic parameters (three-dimensional variations in temperature and humidity), video loops of these image products provide enlightening views of regional flow fields, the movement of tropical and extratropical storm systems, the transfer of moisture between hemispheres and from the tropics to the mid- latitudes, and the dominance of high pressure systems over particular regions of the Earth. Despite the obvious larger scale features, the water vapor imagery contains significant image variability down to the single 8 km GOES pixel. These features can be quantitatively identified and tracked from one time to the next using various image processing techniques. Merrill et al. (1991), Hayden and Schmidt (1992), and Laurent (1993) have documented the operational procedures and capabilities of NOAA and ESOC to produce cloud and water vapor winds. These techniques employ standard correlation and template matching approaches to wind tracking and use qualitative and quantitative procedures to eliminate bad wind vectors from the wind data set. Techniques have also been developed to improve the quality of the operational winds though robust editing procedures (Hayden and Veldon 1991). These quality and control approaches have limitations, are often subjective, and constrain wind variability to be consistent with model derived wind fields. This paper describes research focused on the refinement of objective quality and control parameters for water vapor wind vector data sets. New quality and control measures are developed and employed to provide a more robust wind data set for climate analysis, data assimilation studies, as well as operational weather forecasting. The parameters are applicable to cloud-tracked winds as well with minor

  10. Improved Statistical Method For Hydrographic Climatic Records Quality Control

    Gourrion, J.; Szekely, T.

    2016-02-01

    Climate research benefits from the continuous development of global in-situ hydrographic networks in the last decades. Apart from the increasing volume of observations available on a large range of temporal and spatial scales, a critical aspect concerns the ability to constantly improve the quality of the datasets. In the context of the Coriolis Dataset for ReAnalysis (CORA) version 4.2, a new quality control method based on a local comparison to historical extreme values ever observed is developed, implemented and validated. Temperature, salinity and potential density validity intervals are directly estimated from minimum and maximum values from an historical reference dataset, rather than from traditional mean and standard deviation estimates. Such an approach avoids strong statistical assumptions on the data distributions such as unimodality, absence of skewness and spatially homogeneous kurtosis. As a new feature, it also allows addressing simultaneously the two main objectives of a quality control strategy, i.e. maximizing the number of good detections while minimizing the number of false alarms. The reference dataset is presently built from the fusion of 1) all ARGO profiles up to early 2014, 2) 3 historical CTD datasets and 3) the Sea Mammals CTD profiles from the MEOP database. All datasets are extensively and manually quality controlled. In this communication, the latest method validation results are also presented. The method has been implemented in the latest version of the CORA dataset and will benefit to the next version of the Copernicus CMEMS dataset.

  11. Statistical method for quality control in presence of measurement errors

    Lauer-Peccoud, M.R.

    1998-01-01

    In a quality inspection of a set of items where the measurements of values of a quality characteristic of the item are contaminated by random errors, one can take wrong decisions which are damageable to the quality. So of is important to control the risks in such a way that a final quality level is insured. We consider that an item is defective or not if the value G of its quality characteristic is larger or smaller than a given level g. We assume that, due to the lack of precision of the measurement instrument, the measurement M of this characteristic is expressed by ∫ (G) + ξ where f is an increasing function such that the value ∫ (g 0 ) is known and ξ is a random error with mean zero and given variance. First we study the problem of the determination of a critical measure m such that a specified quality target is reached after the classification of a lot of items where each item is accepted or rejected depending on whether its measurement is smaller or greater than m. Then we analyse the problem of testing the global quality of a lot from the measurements for a example of items taken from the lot. For these two kinds of problems and for different quality targets, we propose solutions emphasizing on the case where the function ∫ is linear and the error ξ and the variable G are Gaussian. Simulation results allow to appreciate the efficiency of the different considered control procedures and their robustness with respect to deviations from the assumptions used in the theoretical derivations. (author)

  12. 42 CFR 84.40 - Quality control plans; filing requirements.

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Quality control plans; filing requirements. 84.40... Control § 84.40 Quality control plans; filing requirements. As a part of each application for approval or... proposed quality control plan which shall be designed to assure the quality of respiratory protection...

  13. 21 CFR 211.22 - Responsibilities of quality control unit.

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Responsibilities of quality control unit. 211.22... Personnel § 211.22 Responsibilities of quality control unit. (a) There shall be a quality control unit that... have been fully investigated. The quality control unit shall be responsible for approving or rejecting...

  14. 30 CFR 28.30 - Quality control plans; filing requirements.

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality control plans; filing requirements. 28... PROTECTION FOR TRAILING CABLES IN COAL MINES Quality Control § 28.30 Quality control plans; filing... part, each applicant shall file with MSHA a proposed quality control plan which shall be designed to...

  15. Quality Controlling CMIP datasets at GFDL

    Horowitz, L. W.; Radhakrishnan, A.; Balaji, V.; Adcroft, A.; Krasting, J. P.; Nikonov, S.; Mason, E. E.; Schweitzer, R.; Nadeau, D.

    2017-12-01

    As GFDL makes the switch from model development to production in light of the Climate Model Intercomparison Project (CMIP), GFDL's efforts are shifted to testing and more importantly establishing guidelines and protocols for Quality Controlling and semi-automated data publishing. Every CMIP cycle introduces key challenges and the upcoming CMIP6 is no exception. The new CMIP experimental design comprises of multiple MIPs facilitating research in different focus areas. This paradigm has implications not only for the groups that develop the models and conduct the runs, but also for the groups that monitor, analyze and quality control the datasets before data publishing, before their knowledge makes its way into reports like the IPCC (Intergovernmental Panel on Climate Change) Assessment Reports. In this talk, we discuss some of the paths taken at GFDL to quality control the CMIP-ready datasets including: Jupyter notebooks, PrePARE, LAMP (Linux, Apache, MySQL, PHP/Python/Perl): technology-driven tracker system to monitor the status of experiments qualitatively and quantitatively, provide additional metadata and analysis services along with some in-built controlled-vocabulary validations in the workflow. In addition to this, we also discuss the integration of community-based model evaluation software (ESMValTool, PCMDI Metrics Package, and ILAMB) as part of our CMIP6 workflow.

  16. Self-organized global control of carbon emissions

    Zhao, Zhenyuan; Fenn, Daniel J.; Hui, Pak Ming; Johnson, Neil F.

    2010-09-01

    There is much disagreement concerning how best to control global carbon emissions. We explore quantitatively how different control schemes affect the collective emission dynamics of a population of emitting entities. We uncover a complex trade-off which arises between average emissions (affecting the global climate), peak pollution levels (affecting citizens’ everyday health), industrial efficiency (affecting the nation’s economy), frequency of institutional intervention (affecting governmental costs), common information (affecting trading behavior) and market volatility (affecting financial stability). Our findings predict that a self-organized free-market approach at the level of a sector, state, country or continent can provide better control than a top-down regulated scheme in terms of market volatility and monthly pollution peaks. The control of volatility also has important implications for any future derivative carbon emissions market.

  17. On global error estimation and control for initial value problems

    J. Lang (Jens); J.G. Verwer (Jan)

    2007-01-01

    textabstractThis paper addresses global error estimation and control for initial value problems for ordinary differential equations. The focus lies on a comparison between a novel approach based onthe adjoint method combined with a small sample statistical initialization and the classical approach

  18. On global error estimation and control for initial value problems

    Lang, J.; Verwer, J.G.

    2007-01-01

    Abstract. This paper addresses global error estimation and control for initial value problems for ordinary differential equations. The focus lies on a comparison between a novel approach based on the adjoint method combined with a small sample statistical initialization and the classical approach

  19. Should we attempt global (inlet engine airframe) control design?

    Carlin, C. M.

    1980-01-01

    The feasibility of multivariable design of the entire airplane control system is briefly addressed. An intermediate step in that direction is to design a control for an inlet engine augmentor system by using multivariable techniques. The supersonic cruise large scale inlet research program is described which will provide an opportunity to develop, integrate, and wind tunnel test a control for a mixed compression inlet and variable cycle engine. The integrated propulsion airframe control program is also discussed which will introduce the problem of implementing MVC within a distributed processing avionics architecture, requiring real time decomposition of the global design into independent modules in response to hardware communication failures.

  20. Determination and evaluation of air quality control. Manual of ambient air quality control in Germany

    Lahmann, E.

    1997-07-01

    Measurement of air pollution emissions and ambient air quality are essential instruments for air quality control. By undertaking such measurements, pollutants are registered both at their place of origin and at the place where they may have an effect on people or the environment. Both types of measurement complement each other and are essential for the implementation of air quality legislation, particularly, in compliance with emission and ambient air quality limit values. Presented here are similar accounts of measurement principles and also contains as an Appendix a list of suitability-tested measuring devices which is based on information provided by the manufacturers. In addition, the guide of ambient air quality control contains further information on discontinuous measurement methods, on measurement planning and on the assessment of ambient air quality data. (orig./SR)

  1. Control of Bank Consolidated Financial Statements Quality

    Margarita S. Ambarchyan

    2013-01-01

    Full Text Available The author presents the multiple linear regression model of bank consolidated financial statements quality. The article considers six characteristics that can be used to estimate the level of bank consolidated financial statements quality. The multiple linear regression model was developed, using the results of point-based system of consolidated financial statements of thirty European bank and financial groups on the basis of the developed characteristics. The author offers to use the characteristic significance factor in the process of consolidated financial statements appraisal by points. The constructed regression model is checked on accuracy and statistical significance. The model can be used by internal auditors and financial analytics as an instrument for bank and non-bank consolidated financial statements quality control

  2. Quality Risk Management: Putting GMP Controls First.

    O'Donnell, Kevin; Greene, Anne; Zwitkovits, Michael; Calnan, Nuala

    2012-01-01

    This paper presents a practical way in which current approaches to quality risk management (QRM) may be improved, such that they better support qualification, validation programs, and change control proposals at manufacturing sites. The paper is focused on the treatment of good manufacturing practice (GMP) controls during QRM exercises. It specifically addresses why it is important to evaluate and classify such controls in terms of how they affect the severity, probability of occurrence, and detection ratings that may be assigned to potential failure modes or negative events. It also presents a QRM process that is designed to directly link the outputs of risk assessments and risk control activities with qualification and validation protocols in the GMP environment. This paper concerns the need for improvement in the use of risk-based principles and tools when working to ensure that the manufacturing processes used to produce medicines, and their related equipment, are appropriate. Manufacturing processes need to be validated (or proven) to demonstrate that they can produce a medicine of the required quality. The items of equipment used in such processes need to be qualified, in order to prove that they are fit for their intended use. Quality risk management (QRM) tools can be used to support such qualification and validation activities, but their use should be science-based and subject to as little subjectivity and uncertainty as possible. When changes are proposed to manufacturing processes, equipment, or related activities, they also need careful evaluation to ensure that any risks present are managed effectively. This paper presents a practical approach to how QRM may be improved so that it better supports qualification, validation programs, and change control proposals in a more scientific way. This improved approach is based on the treatment of what are called good manufacturing process (GMP) controls during those QRM exercises. A GMP control can be considered

  3. 76 FR 10892 - Aquatic Ecosystems, Water Quality, and Global Change: Challenges of Conducting Multi-Stressor...

    2011-02-28

    ...: EPA is announcing the release of the draft report titled, ``Aquatic Ecosystems, Water Quality, and... relative vulnerability of water quality and aquatic ecosystems, across the United States, to the potential... mailing address, and the document title, ``Aquatic Ecosystems, Water Quality, and Global Change...

  4. Quality assurance and quality control for radiotherapy/medical oncology in Europe: guideline development and implementation.

    Valentini, V; Glimelius, B; Frascino, V

    2013-09-01

    The past two decades have brought tremendous changes to the practice of radiation oncology and medical oncology. To manage all the complexities related to the new technologies and the new drugs, the radiation and medical oncologists have to enhance their clinical action and professional skill profile. To accomplish this they have to find reliable tools in the quality of their medical practice and in future research activities. Quality assurance (QA) and quality control (QC) for radiation and medical oncologists mean to clarify the different components of the clinical decision, to supervise with proper methodology the required steps needed to accomplish the agreed outcomes and to control them. Quality for radiation and medical oncology means to supervise each clinical and technical component of the whole process to guarantee that all steps together will arrive at the final and best possible outcome. Key components are guidelines, specialization and a multidisciplinary approach. The research of global quality could represent a further complexity, but it is the best tool to give a perspective and a chance to further improvements of our disciplines and to promote better outcome in all cancer patients. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Microbiological Quality Control of Probiotic Products

    Astashkina, A.P.; Khudyakova, L.I.; Kolbysheva, Y.V.

    2014-01-01

    Microbiological quality control of probiotic products such as Imunele, Dannon, Pomogayka showed that they contain living cultures of the Lactobacillus Bifidobacterium genus in the amount of 107 CFU/ml, which corresponds to the number indicated on the label of products. It is identified that the survival rate of test-strains cultured with pasteurized products does not exceed 10%. The cell concentration of target-microorganisms was reduced by 20-45% after the interaction with living probiotic b...

  6. Mitochondrial quality control in cardiac diseases.

    Juliane Campos

    2016-10-01

    Full Text Available Disruption of mitochondrial homeostasis is a hallmark of cardiac diseases. Therefore, maintenance of mitochondrial integrity through different surveillance mechanisms is critical for cardiomyocyte survival. In this review, we discuss the most recent findings on the central role of mitochondrial quality control processes including regulation of mitochondrial redox balance, aldehyde metabolism, proteostasis, dynamics and clearance in cardiac diseases, highlighting their potential as therapeutic targets.

  7. Quality control and the multicrystal counter

    Hart, G.C.; Davis, K.M.

    1983-01-01

    The reliability of multicrystal counters for use in counting large numbers of radioimmunoassay samples is studied. In particular, the dependencies of the outputs from the array of detectors, and hence their degree of matching, on the count rate and volume of the samples being counted are investigated. Quality control procedures are described to assist in the assurance of consistent performance of the counter in the clinical situation. (U.K.)

  8. The software quality control for gamma spectrometry

    Monte, L.

    1986-01-01

    One of major problems with wich the quality control program of an environmental measurements laboratory is confronted is the evaluation of the performances of software packages for the analysis of gamma-ray spectra. A program of tests for evaluating the performances of the software package (SPECTRAN-F, Canberra Inc.) used by our laboratory is being carried out. In this first paper the results of a preliminary study concerning the evaluation of the performance of the doublet analysis routine are presented

  9. Quality control of estrogen receptor assays.

    Godolphin, W; Jacobson, B

    1980-01-01

    Four types of material have been used for the quality control of routine assays of estrogen receptors in human breast tumors. Pieces of hormone-dependent Nb rat mammary tumors gave a precision about 40%. Rat uteri and rat tumors pulverized at liquid nitrogen temperature and stored as powder yielded precision about 30%. Powdered and lyophilised human tumors appear the best with precision as good as 17%.

  10. [The technological innovation strategy for quality control of Chinese medicine based on Big Data].

    Li, Zhen-hao; Qian, Zhong-zhi; Cheng, Yi-yu

    2015-09-01

    The evolution of the quality control concepts of medical products within the global context and the development of the quality control technology of Chinese medicine are briefly described. Aimed at the bottlenecks in the regulation and quality control of Chinese medicine, using Big Data technology to address the significant challenges in Chinese medicine industry is proposed. For quality standard refinements and internationalization of Chinese medicine, a technological innovation strategy encompassing its methodology, and the R&D direction of the subsequent core technology are also presented.

  11. Global developments of controls of powered roof supports

    Das, S.K. [Indian School of Mines, Dhanbad (India). Centre of Longwall Mine Mechanisation

    1996-04-01

    The efficiency of hydraulic powered roof support systems mainly depends upon the efficient control and operation of hydraulic valves and their associated accessories. From 1961 to 1994 tremendous efforts had been made for the development of higher and higher efficient, reliable but simpler control systems starting from the manual hydraulic to electro-hydraulic and finally computer based electronic control system. A global survey of development of various types and design of control systems of powered roof supports has been made and many of them are highlighted in the paper for making this work a small emblem regarding the efforts of development of the controls of powered roof support systems by the global engineers of the 20th century. Many of the control systems are no longer in use and have totally vanished from this earth and many more control systems including their literatures may vanish from this world in the coming decades. This work may give a guideline regarding the selection of right type of control systems for the powered supports in future. 14 refs., 6 figs.

  12. Statistical process control for radiotherapy quality assurance

    Pawlicki, Todd; Whitaker, Matthew; Boyer, Arthur L.

    2005-01-01

    Every quality assurance process uncovers random and systematic errors. These errors typically consist of many small random errors and a very few number of large errors that dominate the result. Quality assurance practices in radiotherapy do not adequately differentiate between these two sources of error. The ability to separate these types of errors would allow the dominant source(s) of error to be efficiently detected and addressed. In this work, statistical process control is applied to quality assurance in radiotherapy for the purpose of setting action thresholds that differentiate between random and systematic errors. The theoretical development and implementation of process behavior charts are described. We report on a pilot project is which these techniques are applied to daily output and flatness/symmetry quality assurance for a 10 MV photon beam in our department. This clinical case was followed over 52 days. As part of our investigation, we found that action thresholds set using process behavior charts were able to identify systematic changes in our daily quality assurance process. This is in contrast to action thresholds set using the standard deviation, which did not identify the same systematic changes in the process. The process behavior thresholds calculated from a subset of the data detected a 2% change in the process whereas with a standard deviation calculation, no change was detected. Medical physicists must make decisions on quality assurance data as it is acquired. Process behavior charts help decide when to take action and when to acquire more data before making a change in the process

  13. WHO global salm-surv external quality assurance system (EQAS): an important step toward improving the quality of Salmonella serotyping and antimicrobial susceptibility testing worldwide

    Petersen, A.; Aarestrup, Frank Møller; Angulo, F. J.

    2002-01-01

    % of the results were correct. For susceptibility testing, 92% of the results were in agreement with the expected results. However, only 78% of the performed tests with the E. coli ATCC 25922 reference strain were within the quality control range specified by National Committee for Clinical Laboratory Standards...... susceptibility testing through international training courses and an External Quality Assurance System (EQAS). In 2000, 44 WHO Global Salm-Surv member laboratories from 35 countries determined the serotype and antimicrobial susceptibility pattern for eight "blinded" Salmonella isolates. For serotyping, 73...... (NCCLS) guidelines. These EQAS results demonstrate the need for further training to improve the performance of some of the laboratories. WHO Global Salm-Surv activities, including international training courses and EQAS, represent an important step toward improving the quality of Salmonella serotyping...

  14. 7 CFR 58.642 - Quality control tests.

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.642 Section 58.642... Procedures § 58.642 Quality control tests. All mix ingredients shall be subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be made on flow line samples as...

  15. 7 CFR 58.928 - Quality control tests.

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.928 Section 58.928... Procedures § 58.928 Quality control tests. All dairy products and other ingredients shall be subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be...

  16. 7 CFR 58.335 - Quality control tests.

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.335 Section 58.335... Procedures § 58.335 Quality control tests. All milk, cream and related products are subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be made on flow...

  17. Development of phantom periapical for control quality

    Mendes, J.M.S.; Sales Junior, E.S.; Ferreira, F.C.L.; Paschoal, C.M.M.

    2015-01-01

    This study aimed to develop a dental phantom with cysts for evaluation of periapical radiographs that was tested in private dental offices in the city of Maraba, northern Brazil. Through some tests with the object simulator (phantom) were obtained 12 periapical radiographs (one in each of the offices visited) that waking up to the standards of Ordinance No. 453 were visually evaluated by observing the physical parameters of exposure (kVp and mA), time revelation of the radiographic film, later the other radiographs were visually compared with C6 ray set as the default. Among the results, it was found that only two of the twelve rays cysts could not be viewed and, therefore, these two images were deemed unsuitable for accurate diagnosis in the 10 images the cysts could be displayed, however according the images have different qualities comparisons. In addition, it can be concluded that the performance of the phantom was highly satisfactory showing to be efficient for use in quality control testing of dental X-rays, the quality control of radiographs and continuing education of dental professionals for a price much more accessible. (authors)

  18. Quality Management of CERN Vacuum Controls

    Antoniotti, F; Fortescue-Beck, E; Gama, J; Gomes, P; Le Roux, P; Pereira, H; Pigny, G

    2014-01-01

    The vacuum controls Section (TE-VSC-ICM) is in charge of the monitoring, maintenance and consolidation of the control systems of all accelerators and detectors in CERN; this represents 6 000 instruments distributed along 128 km of vacuum chambers, often of heterogeneous architectures and of diverse technical generations. In order to improve the efficiency of the services provided by ICM, to vacuum experts and to accelerator operators, a Quality Management Plan is being put into place. The first step was the standardization of the naming convention across different accelerators. The traceability of problems, requests, repairs, and other actions, has also been put into place (VTL). This was combined with the effort to identify each individual device by a coded label, and register it in a central database (MTF). Occurring in parallel, was the gathering of old documents and the centralization of information concerning architectures, procedures, equipment and settings (EDMS). To describe the topology of control c...

  19. The Copernicus Atmosphere Monitoring Service: facilitating the prediction of air quality from global to local scales

    Engelen, R. J.; Peuch, V. H.

    2017-12-01

    The European Copernicus Atmosphere Monitoring Service (CAMS) operationally provides daily forecasts of global atmospheric composition and regional air quality. The global forecasting system is using ECMWF's Integrated Forecasting System (IFS), which is used for numerical weather prediction and which has been extended with modules for atmospheric chemistry, aerosols and greenhouse gases. The regional forecasts are produced by an ensemble of seven operational European air quality models that take their boundary conditions from the global system and provide an ensemble median with ensemble spread as their main output. Both the global and regional forecasting systems are feeding their output into air quality models on a variety of scales in various parts of the world. We will introduce the CAMS service chain and provide illustrations of its use in downstream applications. Both the usage of the daily forecasts and the usage of global and regional reanalyses will be addressed.

  20. Microbiological quality control practices at Australian Radioisotopes

    Saunders, M.

    1987-01-01

    As a domestic manufacturer of therapeutic substances, Australian Radioisotopes (ARI) must adhere to guidelines set out by the Commonwealth Department of Health in the Code of Good Manufacturing Practices for Therapeutic Goods 1983 (GMP). The GMP gives guidelines for staff training, building requirements, sanitation, documentation and quality control practices. These guidelines form the basis for regular audits performed by officers of the National Biological Standards Laboratories. At Lucas Heights, ARI has combined the principles of the GMP with the overriding precautions introduced for environmental and staff safety and protection. Its policy is to maintain a high level of quality assurance for product identity, purity and sterility and apyrogenicity during all stages of product manufacture

  1. Basic quality control in diagnostic radiology

    Wikstrom, Erik

    2016-01-01

    Along the route toward regular performance of Quality Control in the Diagnostic Imaging sector there are a number of balances to negotiate: Patient/Staff safety considerations vs Regulatory compliance vs Performance of modern equipment vs Clinic's Productivity. At first glance these ambitions may seem in conflict. The tests performed to meet regulatory requirements may or may not bear any semblance to real clinical measurement scenarios. And the process of collecting the data from the quality assurance tests may induce a system down- time that adversely affects the clinic's overall productivity. Furthermore, the time it takes to complete the analysis of the test data and provide the report required to take the facility back into operation is time wasted for patients waiting for a diagnostic imaging exam

  2. Accelerator Control and Global Networks State of the Art

    Gurd, D P

    2004-01-01

    As accelerators increase in size and complexity, demands upon their control systems increase correspondingly. Machine complexity is reflected in complexity of control system hardware and software and careful configuration management is essential. Model-based procedures and fast feedback based upon even faster beam instrumentation are often required. Managing machine protection systems with tens of thousands of inputs is another significant challenge. Increased use of commodity hardware and software introduces new issues of security and control. Large new facilities will increasingly be built by national (e.g. SNS) or international (e.g. a linear collider) collaborations. Building an integrated control system for an accelerator whose development is geographically widespread presents particular problems, not all of them technical. Recent discussions of a “Global Accelerator Network” include the possibility of multiple remote control rooms and no more night shifts. Based upon current experien...

  3. Fiscal federalism approach for controlling global environmental pollution

    Murty, M.N.

    1996-01-01

    It is found that optimal international carbon taxes are country specific and we can decompose a tax on a domestically produced carbon-intensive commodity into a revenue tax, a tax to control local atmospheric pollution and an international carbon tax. It shows that an institutional arrangement for the world economy similar to the fiscal federalism in the federal countries can be useful to internalize the global externalities of atmospheric pollution. 18 refs

  4. Global Sensory Qualities and Aesthetic Experience in Music

    Brattico, Pauli; Brattico, Elvira; Vuust, Peter

    2017-01-01

    A well-known tradition in the study of visual aesthetics holds that the experience of visual beauty is grounded in global computational or statistical properties of the stimulus, for example, scale-invariant Fourier spectrum or self-similarity. Some approaches rely on neural mechanisms, such as efficient computation, processing fluency, or the responsiveness of the cells in the primary visual cortex. These proposals are united by the fact that the contributing factors are hypothesized to be global (i.e., they concern the percept as a whole), formal or non-conceptual (i.e., they concern form instead of content), computational and/or statistical, and based on relatively low-level sensory properties. Here we consider that the study of aesthetic responses to music could benefit from the same approach. Thus, along with local features such as pitch, tuning, consonance/dissonance, harmony, timbre, or beat, also global sonic properties could be viewed as contributing toward creating an aesthetic musical experience. Several such properties are discussed and their neural implementation is reviewed in the light of recent advances in neuroaesthetics. PMID:28424573

  5. ANALYSIS OF QUALITY COSTS FOR STATISTICA QUALITY CONTROL PLANNING

    N. Chiadamrong

    2017-12-01

    Full Text Available Quality has become one or the most important force leading to organizational success and company growth in national and international markets. The return-on-investment from strong and effective quality programs is providing excellent profitability results in firms with effective quality strategies. Due to the wide variation in quality results, the search for the genuine keys to success in quality has become a matter of deep concern to management of companies. This paper suggests a way to quantifying quality costs. As a result, the appropriate quality strategies can be adjusted and set to match with each company situation based on the categorization of the quality costs suggested. This outcome can, then, be used as a guideline for manufactures in setting their suitable quality program, which establishes the proper balance between the costs and customer services.

  6. 40 CFR 75.21 - Quality assurance and quality control requirements.

    2010-07-01

    ... quality assurance audit or any other audit, the system is out-of-control. The owner or operator shall... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Quality assurance and quality control... assurance and quality control requirements. (a) Continuous emission monitoring systems. The owner or...

  7. Distributed sensor architecture for intelligent control that supports quality of control and quality of service.

    Poza-Lujan, Jose-Luis; Posadas-Yagüe, Juan-Luis; Simó-Ten, José-Enrique; Simarro, Raúl; Benet, Ginés

    2015-02-25

    This paper is part of a study of intelligent architectures for distributed control and communications systems. The study focuses on optimizing control systems by evaluating the performance of middleware through quality of service (QoS) parameters and the optimization of control using Quality of Control (QoC) parameters. The main aim of this work is to study, design, develop, and evaluate a distributed control architecture based on the Data-Distribution Service for Real-Time Systems (DDS) communication standard as proposed by the Object Management Group (OMG). As a result of the study, an architecture called Frame-Sensor-Adapter to Control (FSACtrl) has been developed. FSACtrl provides a model to implement an intelligent distributed Event-Based Control (EBC) system with support to measure QoS and QoC parameters. The novelty consists of using, simultaneously, the measured QoS and QoC parameters to make decisions about the control action with a new method called Event Based Quality Integral Cycle. To validate the architecture, the first five Braitenberg vehicles have been implemented using the FSACtrl architecture. The experimental outcomes, demonstrate the convenience of using jointly QoS and QoC parameters in distributed control systems.

  8. Distributed Sensor Architecture for Intelligent Control that Supports Quality of Control and Quality of Service

    Jose-Luis Poza-Lujan

    2015-02-01

    Full Text Available This paper is part of a study of intelligent architectures for distributed control and communications systems. The study focuses on optimizing control systems by evaluating the performance of middleware through quality of service (QoS parameters and the optimization of control using Quality of Control (QoC parameters. The main aim of this work is to study, design, develop, and evaluate a distributed control architecture based on the Data-Distribution Service for Real-Time Systems (DDS communication standard as proposed by the Object Management Group (OMG. As a result of the study, an architecture called Frame-Sensor-Adapter to Control (FSACtrl has been developed. FSACtrl provides a model to implement an intelligent distributed Event-Based Control (EBC system with support to measure QoS and QoC parameters. The novelty consists of using, simultaneously, the measured QoS and QoC parameters to make decisions about the control action with a new method called Event Based Quality Integral Cycle. To validate the architecture, the first five Braitenberg vehicles have been implemented using the FSACtrl architecture. The experimental outcomes, demonstrate the convenience of using jointly QoS and QoC parameters in distributed control systems.

  9. Global differential geometry: An introduction for control engineers

    Doolin, B. F.; Martin, C. F.

    1982-01-01

    The basic concepts and terminology of modern global differential geometry are discussed as an introduction to the Lie theory of differential equations and to the role of Grassmannians in control systems analysis. To reach these topics, the fundamental notions of manifolds, tangent spaces, vector fields, and Lie algebras are discussed and exemplified. An appendix reviews such concepts needed for vector calculus as open and closed sets, compactness, continuity, and derivative. Although the content is mathematical, this is not a mathematical treatise but rather a text for engineers to understand geometric and nonlinear control.

  10. Global Horizontal Control Network of Shanghai Synchrotron Radiation Facility

    Yu Chenghao; Ke Ming; Du Hanwen; Yin Lixin; Zhao Zhentang; Dong Lan; Huang Kaixi

    2009-01-01

    As a national big scientific engineering, Shanghai Synchrotron Radiation Facility (SSRF) has rigid requirement to the components with sub-millimeter accuracy. In the process of survey and positioning global control network is a connecting link, which determines the position relationship between building and accelerator devices, and provides high accuracy datum to local control network. Within the designing process, building and devices are very restrict. While among observation, it's hard to be observed and abound with disadvantages. With continuous optimization and careful operation, super-high accuracy of 0.3 mm within 400 m circumference was achieved and slab's periodic movement could be seen through 3 times measurement. (authors)

  11. Quality control in quantitative computed tomography

    Jessen, K.A.; Joergensen, J.

    1989-01-01

    Computed tomography (CT) has for several years been an indispensable tool in diagnostic radiology, but it is only recently that extraction of quantitative information from CT images has been of practical clinical value. Only careful control of the scan parameters, and especially the scan geometry, allows useful information to be obtained; and it can be demonstrated by simple phantom measurements how sensitive a CT system can be to variations in size, shape and position of the phantom in the gantry aperture. Significant differences exist between systems that are not manifested in normal control of image quality and general performance tests. Therefore an actual system has to be analysed for its suitability for quantitative use of the images before critical clinical applications are justified. (author)

  12. Quality control concept for radioactive waste packages

    Warnecke, E.; Martens, B.R.; Odoj, R.

    1990-01-01

    In the Federal Republic of Germany a contract with the BfS for the performance of quality control measures is necessary. It is principally possible to apply two alternative methods: random checks on waste packages or qualification of conditioning processes with subsequent inspections. Priority is given to the control by the process qualification. Both methods have successfully been developed in the Federal Republic of Germany and can be applied. In the course of the qualification of conditioning processes it must be demonstrated by inactive and/or active runs that waste packages are produced which fulfil the waste acceptance requirements. The qualification results in the fixation of a handbook for the operation of the respective conditioning process including the process instrumentation and the operational margins. The qualified process will be inspected to assure the compliance of the actual operation with the conditions fixed in the handbook. (orig./DG)

  13. Software Quality Control at Belle II

    Ritter, M.; Kuhr, T.; Hauth, T.; Gebard, T.; Kristof, M.; Pulvermacher, C.; Belle Software Group, II

    2017-10-01

    Over the last seven years the software stack of the next generation B factory experiment Belle II has grown to over one million lines of C++ and Python code, counting only the part included in offline software releases. There are several thousand commits to the central repository by about 100 individual developers per year. To keep a coherent software stack of high quality that it can be sustained and used efficiently for data acquisition, simulation, reconstruction, and analysis over the lifetime of the Belle II experiment is a challenge. A set of tools is employed to monitor the quality of the software and provide fast feedback to the developers. They are integrated in a machinery that is controlled by a buildbot master and automates the quality checks. The tools include different compilers, cppcheck, the clang static analyzer, valgrind memcheck, doxygen, a geometry overlap checker, a check for missing or extra library links, unit tests, steering file level tests, a sophisticated high-level validation suite, and an issue tracker. The technological development infrastructure is complemented by organizational means to coordinate the development.

  14. Collection of Condensate Water: Global Potential and Water Quality Impacts

    Loveless, Kolin Joseph

    2012-12-28

    Water is a valuable resource throughout the world, especially in hot, dry climates and regions experiencing significant population growth. Supplies of fresh water are complicated by the economic and political conditions in many of these regions. Technologies that can supply fresh water at a reduced cost are therefore becoming increasingly important and the impact of such technologies can be substantial. This paper considers the collection of condensate water from large air conditioning units as a possible method to alleviate water scarcity issues. Using the results of a climate model that tested data collected from 2000 to 2010, we have identified areas in the world with the greatest collection potential. We gave special consideration to areas with known water scarcities, including the coastal regions of the Arabian Peninsula, Sub-Saharan Africa and South Asia. We found that the quality of the collected water is an important criterion in determining the potential uses for this water. Condensate water samples were collected from a few locations in Saudi Arabia and detailed characterizations were conducted to determine the quality of this water. We found that the quality of condensate water collected from various locations and types of air conditioners was very high with conductivities reaching as low as 18 μS/cm and turbidities of 0. 041 NTU. The quality of the collected condensate was close to that of distilled water and, with low-cost polishing treatments, such as ion exchange resins and electrochemical processes, the condensate quality could easily reach that of potable water. © 2012 Springer Science+Business Media Dordrecht.

  15. Metrological aspects to quality control for natural gas analyses

    Ribeiro, Claudia Cipriano; Borges, Cleber Nogueira; Cunha, Valnei S. [Instituto Nacional de Metrologia, Normalizacao e Qualidade Industrial (INMETRO), Rio de Janeiro, RJ (Brazil); Augusto, Cristiane R. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil); Augusto, Marco Ignazio [Companhia Estadual de Gas do Rio de Janeiro (CEG), RJ (Brazil)

    2008-07-01

    The Product's Quality and Services are fundamental topics in the globalized commercial relationship inclusive concern the measurements in natural gas. Considerable investments were necessary for industry especially about the quality control in the commercialized gas with an inclusion of the natural gas in Brazilian energetic resources The Brazilian Regulatory Agency, ANP - Agencia Nacional de Petroleo, Gas Natural e Biocombustiveis - created the Resolution ANP no.16. This Resolution defines the natural gas specification, either national or international source, for commercialization in Brazil and list the tolerance concentration for some components. Between of this components are the inert compounds like the CO{sub 2} and N{sub 2}. The presence of this compounds reduce the calorific power, apart from increase the resistance concern the detonation in the case of vehicular application, and occasion the reduction in the methane concentration in the gas. Controls charts can be useful to verify if the process are or not under Statistical Control. The process can be considerate under statistical control if the measurements have it values between in lower and upper limits stated previously The controls charts can be approach several characteristics in each subgroup: means, standard deviations, amplitude or proportion of defects. The charts are draws for a specific characteristic and to detect some deviate in the process under specific environment conditions. The CEG - Companhia de Distribuicao de Gas do Rio de Janeiro and the DQUIM - Chemical Metrology Division has an agreement for technical cooperation in research and development of gas natural composition Concern the importance of the natural gas in the Nation development, as well as the question approaching the custody transference, the objective of this work is demonstrate the control quality of the natural gas composition between the CEG laboratory and the DQUIM laboratory aiming the quality increase of the

  16. Quality control of nuclear medicine instruments

    1984-11-01

    This document, which gives detailed guidance on the quality control of the various electronic instruments used for radiation detection and measurement in nuclear medicine, stems from the work of two Advisory Groups convened by the International Atomic Energy Agency (IAEA). A preliminary document, including recommended test schedules but lacking actual protocols for the tests, was drawn up by the first of these groups, meeting at the IAEA Headquarters in Vienna in 1979. A revised and extended version, incorporating recommended test protocols, was prepared by the second Group, meeting likewise in Vienna in 1982. This version is the model for the present text. The document should be of value to all nuclear medicine units, and especially to those in developing countries, in the initiation or revision of schemes for the quality control of their instruments. Its recommendations have provided the basis for instruction in two IAEA regional technical co-operation projects in the subject field, one initiated in 1981 for countries of Latin America and one initiated in 1982 for countries of Asia and the Pacific

  17. Toward standardising gamma camera quality control procedures

    Alkhorayef, M.A.; Alnaaimi, M.A.; Alduaij, M.A.; Mohamed, M.O.; Ibahim, S.Y.; Alkandari, F.A.; Bradley, D.A.

    2015-01-01

    Attaining high standards of efficiency and reliability in the practice of nuclear medicine requires appropriate quality control (QC) programs. For instance, the regular evaluation and comparison of extrinsic and intrinsic flood-field uniformity enables the quick correction of many gamma camera problems. Whereas QC tests for uniformity are usually performed by exposing the gamma camera crystal to a uniform flux of gamma radiation from a source of known activity, such protocols can vary significantly. Thus, there is a need for optimization and standardization, in part to allow direct comparison between gamma cameras from different vendors. In the present study, intrinsic uniformity was examined as a function of source distance, source activity, source volume and number of counts. The extrinsic uniformity and spatial resolution were also examined. Proper standard QC procedures need to be implemented because of the continual development of nuclear medicine imaging technology and the rapid expansion and increasing complexity of hybrid imaging system data. The present work seeks to promote a set of standard testing procedures to contribute to the delivery of safe and effective nuclear medicine services. - Highlights: • Optimal parameters for quality control of the gamma camera are proposed. • For extrinsic and intrinsic uniformity a minimum of 15,000 counts is recommended. • For intrinsic flood uniformity the activity should not exceed 100 µCi (3.7 MBq). • For intrinsic uniformity the source to detector distance should be at least 60 cm. • The bar phantom measurement must be performed with at least 15 million counts.

  18. Performance and quality control of scintillation cameras

    Moretti, J.L.; Iachetti, D.

    1983-01-01

    Acceptance testing, quality and control assurance of gamma-cameras are a part of diagnostic quality in clinical practice. Several parameters are required to achieve a good diagnostic reliability: intrinsic spatial resolution, spatial linearity, uniformities, energy resolution, count-rate characteristics, multiple window spatial analysis. Each parameter was measured and also estimated by a test easy to implement in routine practice. Material required was a 4028 multichannel analyzer linked to a microcomputeur, mini-computers and a set of phantoms (parallel slits, diffusing phantom, orthogonal hole transmission pattern). Gamma-cameras on study were:CGR 3400, CGR 3420, G.E.4000. Siemens ZLC 75 and large field Philips. Several tests proposed by N.E.M.A. and W.H.O. have to be improved concerning too punctual spatial determinations during distortion measurements with multiple window. Contrast control of image need to be monitored with high counting rate. This study shows the need to avoid punctual determinations and the interest to give sets of values of the same parameter on the whole field and to report mean values with their standard variation [fr

  19. Quality control of radioiodinated gastrin for radioimmunoassay

    Ginabreda, M.G.P.; Borghi, V.C.; Bettarello, A.

    1988-07-01

    Radioiodinated human gastrin has been prepared at IPEN laboratory for radioimmunoassay use. This work developed the quality control of this tracer analyzing parameters of the labelling reaction, chromatographic purification and radioimmunoassay. The radioiodination yield obtained in five experiments was reproducible and similar when analyzed on 7% polyaraylamide gel eletrophoresis - PAGE - (mean + - SD of 51.70 + - 10.76%) and by1 25 I incorporation checked through thrichloroacetic acid precipitation - TCA - (57-36 + - 9.69%). Similary, after purification the labelled gastrin revaled high and reproducible purity degree when submitted to PAGE (96.57 + - 1.06%) and CA (94.82 + - 4.20%) analysis. The respective specific activities varied from 62 to 307 uCi/ug, being determined by the self-displacement method, which is based on the immunoactivity of the tracer. In this way, the antibody titers required to bind 50% of the tracer ranged from 1:32.000 to 1:180.000. Consequently, the respective doses producing 50% fall in the maximum response of the radioimmunoassays ranged from 155.0 to 24.0 pmol/1, but remained unchanged for each tracer even after three months of its preparations. The tracers presented very low non-specific binding values (1.78 + - 0.79%), stablespecific binding values (46.49 + - 5.65%) and a good between-assay precision, evaluated by an internal quality control sample (25.71 + - 4.30%) with coefficient of variation of 16.74%). The PAGE analysis of the unlabeled gastrin used in the first and last radioiodination revealed an unique and unaltered component, confirming the quality of the tracers. (author) [pt

  20. Goals and strategies in the global control design of the OAJ Robotic Observatory

    Yanes-Díaz, A.; Rueda-Teruel, S.; Antón, J. L.; Rueda-Teruel, F.; Moles, M.; Cenarro, A. J.; Marín-Franch, A.; Ederoclite, A.; Gruel, N.; Varela, J.; Cristóbal-Hornillos, D.; Chueca, S.; Díaz-Martín, M. C.; Guillén, L.; Luis-Simoes, R.; Maícas, N.; Lamadrid, J. L.; López-Sainz, A.; Hernández-Fuertes, J.; Valdivielso, L.; Mendes de Oliveira, C.; Penteado, P.; Schoenell, W.; Kanaan, A.

    2012-09-01

    There are many ways to solve the challenging problem of making a high performance robotic observatory from scratch. The Observatorio Astrofísico de Javalambre (OAJ) is a new astronomical facility located in the Sierra de Javalambre (Teruel, Spain) whose primary role will be to conduct all-sky astronomical surveys. The OAJ control system has been designed from a global point of view including astronomical subsystems as well as infrastructures and other facilities. Three main factors have been considered in the design of a global control system for the robotic OAJ: quality, reliability and efficiency. We propose CIA (Control Integrated Architecture) design and OEE (Overall Equipment Effectiveness) as a key performance indicator in order to improve operation processes, minimizing resources and obtaining high cost reduction whilst maintaining quality requirements. The OAJ subsystems considered for the control integrated architecture are the following: two wide-field telescopes and their instrumentation, active optics subsystems, facilities for sky quality monitoring (seeing, extinction, sky background, sky brightness, cloud distribution, meteorological station), domes and several infrastructure facilities such as water supply, glycol water, water treatment plant, air conditioning, compressed air, LN2 plant, illumination, surveillance, access control, fire suppression, electrical generators, electrical distribution, electrical consumption, communication network, Uninterruptible Power Supply and two main control rooms, one at the OAJ and the other remotely located in Teruel, 40km from the observatory, connected through a microwave radio-link. This paper presents the OAJ strategy in control design to achieve maximum quality efficiency for the observatory processes and operations, giving practical examples of our approach.

  1. 7 CFR 58.141 - Alternate quality control program.

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Alternate quality control program. 58.141 Section 58... Service 1 Quality Specifications for Raw Milk § 58.141 Alternate quality control program. When a plant has in operation an acceptable quality program, at the producer level, which is approved by the...

  2. Global Influences on National Definitions of Quality Education: Examples from Spain and Italy

    Engel, Laura C.; Rutkowski, David

    2014-01-01

    There is increasing attention worldwide to advancing quality education. Beyond a rhetorical aim, many international organizations and national education systems have articulated a commitment to promoting measures of quality education through the development of educational indicators. This article broadly explores the global influences on national…

  3. Conceptualising Education Quality in Zambia: A Comparative Analysis across the Local, National and Global Discourses

    Lee, Jeongmin; Zuilkowski, Stephanie Simmons

    2017-01-01

    Building on the Education for All movement, the 2030 Agenda for Sustainable Development re-emphasises quality education as a discrete goal. Contextualising the discussion surrounding this goal in Zambia, this study examines how education quality is conceptualised by educational stakeholders at local, national, and global levels. Triangulating…

  4. A Framework for Quality Assurance in Globalization of Higher Education: A View toward the Future

    Job, Jennifer; Sriraman, Bharath

    2013-01-01

    In this paper we theorize a framework for discussing quality assurance of globalized models of education used internationally. The philosophical assumption that homogeneity of perspectives achieves objectivity in practice is argued against using the examples of (a) Brain drain, and (b) Profit over quality. We present a coherent real world scenario…

  5. Technology requirement for Halal quality control | Husny | Journal of ...

    Technology requirement for Halal quality control. ... Findings show that each industry segments have different technology characteristics preference. ... Keywords: halal industry, quality control; technology assistance; food and beverage; ...

  6. Improved statistical method for temperature and salinity quality control

    Gourrion, Jérôme; Szekely, Tanguy

    2017-04-01

    Climate research and Ocean monitoring benefit from the continuous development of global in-situ hydrographic networks in the last decades. Apart from the increasing volume of observations available on a large range of temporal and spatial scales, a critical aspect concerns the ability to constantly improve the quality of the datasets. In the context of the Coriolis Dataset for ReAnalysis (CORA) version 4.2, a new quality control method based on a local comparison to historical extreme values ever observed is developed, implemented and validated. Temperature, salinity and potential density validity intervals are directly estimated from minimum and maximum values from an historical reference dataset, rather than from traditional mean and standard deviation estimates. Such an approach avoids strong statistical assumptions on the data distributions such as unimodality, absence of skewness and spatially homogeneous kurtosis. As a new feature, it also allows addressing simultaneously the two main objectives of an automatic quality control strategy, i.e. maximizing the number of good detections while minimizing the number of false alarms. The reference dataset is presently built from the fusion of 1) all ARGO profiles up to late 2015, 2) 3 historical CTD datasets and 3) the Sea Mammals CTD profiles from the MEOP database. All datasets are extensively and manually quality controlled. In this communication, the latest method validation results are also presented. The method has already been implemented in the latest version of the delayed-time CMEMS in-situ dataset and will be deployed soon in the equivalent near-real time products.

  7. Managing Air Quality - Control Strategies to Achieve Air Pollution Reduction

    Considerations in designing an effective control strategy related to air quality, controlling pollution sources, need for regional or national controls, steps to developing a control strategy, and additional EPA resources.

  8. 10 CFR 26.137 - Quality assurance and quality control.

    2010-01-01

    ... cutoff concentration for the compound of interest, a control without the compound of interest (i.e., a certified negative control), and a control with at least one of the compounds of interest at a measurable... calibrator, a control without the compound of interest (i.e., a certified negative control), and a control...

  9. Quality assurance systems – the difficulties in providing a global unified system for Surveyors

    Goodhead, Tim

    2012-01-01

    This paper will analyse the difficulties in providing a global quality assurance system for Surveyors. Using case studies from the United Kingdom and elsewhere opportunities for harmonising Quality Assurance systems will be explored. The difficulties in moving towards common quality assurance systems will be analysed. Possible alternatives in the form of the development a knowledge bank of mutual agreements and top up qualifications will be investigated. The paper also looks at the role of FI...

  10. 14 CFR 21.147 - Changes in quality control system.

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Changes in quality control system. 21.147 Section 21.147 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... quality control system. After the issue of a production certificate, each change to the quality control...

  11. 14 CFR 145.211 - Quality control system.

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Quality control system. 145.211 Section 145...) SCHOOLS AND OTHER CERTIFICATED AGENCIES REPAIR STATIONS Operating Rules § 145.211 Quality control system. (a) A certificated repair station must establish and maintain a quality control system acceptable to...

  12. 7 CFR 58.523 - Laboratory and quality control tests.

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  13. 18 CFR 12.40 - Quality control programs.

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Quality control... PROJECT WORKS Other Responsibilities of Applicant or Licensee § 12.40 Quality control programs. (a... meeting any requirements or standards set by the Regional Engineer. If a quality control program is...

  14. 21 CFR 640.56 - Quality control test for potency.

    2010-04-01

    ... quality control test for potency may be performed by a clinical laboratory which meets the standards of... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Quality control test for potency. 640.56 Section...) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Cryoprecipitate § 640.56 Quality control...

  15. Acceptance, commissioning and quality control in radiosurgery

    Toreti, Dalila Luzia

    2009-01-01

    Stereotactic Radiosurgery is a treatment technique that uses narrow beams of radiation focused with great accuracy in a small lesion. The introduction of micro multi leaf collimators (mMLC) allows this technique to reach a higher degree of dose conformation of the target lesion allowing a smaller irradiation of critical structures and normal tissues. This paper presents the results of the acceptance tests and commissioning of a Varian 6EX linear accelerator dedicated to radiosurgery associated with the BrainLab micro multi leaf collimator installed in the Hospital das Clinicas da Faculdade de Medicina da USP (HC-FMUSP) and establish feasible quality assurance program for the services that employ this special technique. The results of the acceptance tests were satisfactory and are willing with the specifications provided by the manufacturer and the commissioning tests were within the international recommendations. The tests and measures that are part of quality control process should be specific to each treatment unit, and the need, frequency and levels of tolerance

  16. Quality control in nuclear fuel fabrication

    Abdelhalim, A.S.; Elsayed, A.A.; Shaaban, H.I.

    1988-01-01

    The department of metallurgy, NRC Inchass is embarking on a programme of on a laboratory scale, fuel pins containing uranium dioxide pellets are going to be produced. The department is making use of the expertise and equipment at present available and is going to utilize the new fuel pin fabrication unit which would be shortly in operation. The fabrication and testing of uranium dioxide pellets then gradually adapt them and develop, a national know how in this field. This would also involve building up of indigenous experience through proper training of qualified personnel. That are applied to ensure quality of U o 2 pellets, the techniques implemented, the equipment used and the specifications of the equipment presently available. The following parameters are subject to quality control tests: density. O/U ration, hydrogen content, microstructure, each property will be discussed, measurements related to U o 2 powders, including flow ability, bulk density, O/U ratio, bet surface area and water content will be critically discussed. Relevant tests to ensure Q C of pellets are reviewed. These include surface integrity, density, dimensions, microstructure.4 fig., 1 tab

  17. Tools for quality control of fingerprint databases

    Swann, B. Scott; Libert, John M.; Lepley, Margaret A.

    2010-04-01

    Integrity of fingerprint data is essential to biometric and forensic applications. Accordingly, the FBI's Criminal Justice Information Services (CJIS) Division has sponsored development of software tools to facilitate quality control functions relative to maintaining its fingerprint data assets inherent to the Integrated Automated Fingerprint Identification System (IAFIS) and Next Generation Identification (NGI). This paper provides an introduction of two such tools. The first FBI-sponsored tool was developed by the National Institute of Standards and Technology (NIST) and examines and detects the spectral signature of the ridge-flow structure characteristic of friction ridge skin. The Spectral Image Validation/Verification (SIVV) utility differentiates fingerprints from non-fingerprints, including blank frames or segmentation failures erroneously included in data; provides a "first look" at image quality; and can identify anomalies in sample rates of scanned images. The SIVV utility might detect errors in individual 10-print fingerprints inaccurately segmented from the flat, multi-finger image acquired by one of the automated collection systems increasing in availability and usage. In such cases, the lost fingerprint can be recovered by re-segmentation from the now compressed multi-finger image record. The second FBI-sponsored tool, CropCoeff was developed by MITRE and thoroughly tested via NIST. CropCoeff enables cropping of the replacement single print directly from the compressed data file, thus avoiding decompression and recompression of images that might degrade fingerprint features necessary for matching.

  18. Quality control tests for conventional mammography

    Dawod, Alnazer Ahmed Ibrahim

    2014-12-01

    Mammography is this the test that allows the radiologist to look at images of the inside of the breasts. Mammograms help detect breast cancer early successful treatment of breast cancer depends on that early diagnosis. Breast cancer is a very common condition. About one in every nine women develops breast cancer by the age of eighty. In addition to the clinical examination and self-examination, mammography plays important role in the detection of breast cancer before they become clinically visible tumors. The mammography is the most common test for early detection of breast cancer. Quality control techniques that done ensured importance of this programme to produce images with good diagnostic values and help radiologist to diagnose breast discase easily and avoid exposing patient to radiation hazards.(Author)

  19. Analytical quality control [An IAEA service

    NONE

    1973-07-01

    In analytical chemistry the determination of small or trace amounts of elements or compounds in different types of materials is increasingly important. The results of these findings have a great influence on different fields of science, and on human life. Their reliability, precision and accuracy must, therefore, be checked by analytical quality control measures. The International Atomic Energy Agency (IAEA) set up an Analytical Quality Control Service (AQCS) in 1962 to assist laboratories in Member States in the assessment of their reliability in radionuclide analysis, and in other branches of applied analysis in which radionuclides may be used as analytical implements. For practical reasons, most analytical laboratories are not in a position to check accuracy internally, as frequently resources are available for only one method; standardized sample material, particularly in the case of trace analysis, is not available and can be prepared by the institutes themselves only in exceptional cases; intercomparisons are organized rather seldom and many important types of analysis are so far not covered. AQCS assistance is provided by the shipment to laboratories of standard reference materials containing known quantities of different trace elements or radionuclides, as well as by the organization of analytical intercomparisons in which the participating laboratories are provided with aliquots of homogenized material of unknown composition for analysis. In the latter case the laboratories report their data to the Agency's laboratory, which calculates averages and distributions of results and advises each laboratory of its performance relative to all the others. Throughout the years several dozens of intercomparisons have been organized and many thousands of samples provided. The service offered, as a consequence, has grown enormously. The programme for 1973 and 1974, which is currently being distributed to Member States, will contain 31 different types of materials.

  20. The growing need for analytical quality control

    Suschny, O.; Richman, D.M.

    1974-01-01

    Technological development in a country is directly dependent upon its analytical chemistry or measurement capability, because it is impossible to achieve any level of technological sophistication without the ability to measure. Measurement capability is needed to determine both technological competence and technological consequence. But measurement itself is insufficient. There must be a standard or a reference for comparison. In the complicated world of chemistry the need for reference materials grows with successful technological development. The International Atomic Energy Agency has been distributing calibrated radioisotope solutions, standard reference materials and intercomparison materials since the early 1960's. The purpose of this activity has been to help laboratories in its Member States to assess and, if necessary, to improve the reliability of their analytical work. The value and continued need of this service has been demonstrated by the results of many intercomparisons which proved that without continuing analytical quality control activities, adequate reliability of analytical data could not be taken for granted. Analytical chemistry, lacking the glamour of other aspects of the physical sciences, has not attracted the attention it deserves, but in terms of practical importance, it warrants high priority in any developing technological scheme, because without it there is little chance to evaluate technological success or failure or opportunity to identify the reasons for success or failure. The scope and the size of the future programme of the IAEA in this field has been delineated by recommendations made by several Panels of Experts; all have agreed on the importance of this programme and made detailed recommendations in their areas of expertise. The Agency's resources are limited and it cannot on its own undertake the preparation and distribution of all the materials needed. It can, however, offer a focal point to bring together different

  1. Terms and definitions of quality assurance/quality control

    Kaden, W.

    1980-01-01

    Terms of quality assurance are defined and interpreted. Reference is made to the IAEA Code of Practice and to other important Codes and Standards like ANSI, ASME and KTA. The relevance of these terms to everyday's work and problems of a quality assurance engineer is explained. (orig.)

  2. [Compatibility of different quality control systems].

    Invernizzi, Enrico

    2002-01-01

    Management of the good laboratory practice (GLP) quality system presupposes its linking to a basic recognized and approved quality system, from which it can draw on management procedures common to all quality systems, such as the ISO 9000 set of norms. A quality system organized in this way can also be integrated with other dedicated quality systems, or parts of them, to obtain principles or management procedures for specific topics. The aim of this organization is to set up a reliable, recognized quality system compatible with the principles of GLP and other quality management systems, which provides users with a simplified set of easily accessible management tools and answers. The organization of this quality system is set out in the quality assurance programme, which is actually the document in which the test facility incorporates the GLP principles into its own quality organization.

  3. Evaluation and Quality Control for the Copernicus Seasonal Forecast Systems

    Manubens, N.; Hunter, A.; Bedia, J.; Bretonnière, P. A.; Bhend, J.; Doblas-Reyes, F. J.

    2017-12-01

    The EU funded Copernicus Climate Change Service (C3S) will provide authoritative information about past, current and future climate for a wide range of users, from climate scientists to stakeholders from a wide range of sectors including insurance, energy or transport. It has been recognized that providing information about the products' quality and provenance is paramount to establish trust in the service and allow users to make best use of the available information. This presentation outlines the work being conducted within the Quality Assurance for Multi-model Seasonal Forecast Products project (QA4Seas). The aim of QA4Seas is to develop a strategy for the evaluation and quality control (EQC) of the multi-model seasonal forecasts provided by C3S. First, we present the set of guidelines the data providers must comply with, ensuring the data is fully traceable and harmonized across data sets. Second, we discuss the ongoing work on defining a provenance and metadata model that is able to encode such information, and that can be extended to describe the steps followed to obtain the final verification products such as maps and time series of forecast quality measures. The metadata model is based on the Resource Description Framework W3C standard, being thus extensible and reusable. It benefits from widely adopted vocabularies to describe data provenance and workflows, as well as from expert consensus and community-support for the development of the verification and downscaling specific ontologies. Third, we describe the open source software being developed to generate fully reproducible and certifiable seasonal forecast products, which also attaches provenance and metadata information to the verification measures and enables the user to visually inspect the quality of the C3S products. QA4Seas is seeking collaboration with similar initiatives, as well as extending the discussion to interested parties outside the C3S community to share experiences and establish global

  4. Breaking Boundaries: Quality E-Learning for the Global Knowledge Society

    Lalilta Rajasingham

    2009-03-01

    Full Text Available The ideas and issues raised in this paper reflect a global challenge to understand the nature of E-learning in a knowledge society so that appropriate quality frameworks can be developed for new educational environments. E-learning and virtual classes evolved from distance education and struggle to gain recognition in mainstream education as legitimate quality higher education providers. The increasing use of information technology advances, particularly the internet present new educational paradigms and models that challenge conventional assumptions and indicators of quality assurance. What is needed is the development of global standards and quality assurance frameworks that can improve pedagogy in diverse cultural, knowledge and delivery paradigms. This paper seeks to explore how quality is defined, who sets whose standards, who will teach what to whom with what effect in a world of competing paradigms and parallel worlds of reality and virtual reality.

  5. A global conformance quality model. A new strategic tool for minimizing defects caused by variation, error, and complexity

    Hinckley, C. Martin [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    1994-01-01

    The performance of Japanese products in the marketplace points to the dominant role of quality in product competition. Our focus is motivated by the tremendous pressure to improve conformance quality by reducing defects to previously unimaginable limits in the range of 1 to 10 parts per million. Toward this end, we have developed a new model of conformance quality that addresses each of the three principle defect sources: (1) Variation, (2) Human Error, and (3) Complexity. Although the role of variation in conformance quality is well documented, errors occur so infrequently that their significance is not well known. We have shown that statistical methods are not useful in characterizing and controlling errors, the most common source of defects. Excessive complexity is also a root source of defects, since it increases errors and variation defects. A missing link in the defining a global model has been the lack of a sound correlation between complexity and defects. We have used Design for Assembly (DFA) methods to quantify assembly complexity and have shown that assembly times can be described in terms of the Pareto distribution in a clear exception to the Central Limit Theorem. Within individual companies we have found defects to be highly correlated with DFA measures of complexity in broad studies covering tens of millions of assembly operations. Applying the global concepts, we predicted that Motorola`s Six Sigma method would only reduce defects by roughly a factor of two rather than orders of magnitude, a prediction confirmed by Motorola`s data. We have also shown that the potential defects rates of product concepts can be compared in the earliest stages of development. The global Conformance Quality Model has demonstrated that the best strategy for improvement depends upon the quality control strengths and weaknesses.

  6. Requirements for quality control of analytical data

    Westmoreland, R.D.; Bartling, M.H.

    1990-07-01

    The National Contingency Plan (NCP) of the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) provides procedures for the identification, evaluation, and remediation of past hazardous waste disposal sites. The Hazardous Materials Response section of the NCP consists of several phases: Preliminary Assessment, Site Inspection, Remedial Investigation, Feasibility Study, Remedial Design, and Remedial Action. During any of these phases, analysis of soil, water, and waste samples may be performed. The Hazardous Waste Remedial Actions Program (HAZWRAP) is involved in performing field investigations and sample analyses pursuant to the NCP for the US Department of Energy and other federal agencies. The purpose of this document is to specify the requirements of Martin Marietta Energy Systems, Inc., for the control of accuracy, precision, and completeness of samples and data from the point of collection through analysis. Requirements include data reduction and reporting of resulting environmentally related data. Because every instance and concern may not be addressed in this document, HAZWRAP subcontractors are encouraged to discuss any questions with the Analytical Quality Control Specialist (AQCS) and the HAZWRAP Project Manager. This revision supercedes all other versions of this document

  7. Design and quality control of an environmental data acquisition system

    FANJIRINDRATOVO, T.

    2009-01-01

    The present work is focused on the design of a microcontroller based measurement system and the control quality to validate it. So, a mobile instrument called DALENPA was designed to measure and log the following data: atmospheric pressure, ambient temperature, relative humidity, wind speed and direction, air dose rate, geographical coordinates by an embedded GPS receiver. The instrument is autonomous in energy by solar panel and can be connected to a PC directly or by modem. After, the quality control is based on the calibartion in a secondary laboratory. The target is to get its calibration curve and the estimation of global uncertainties. This estimation wants to include all sources of uncertainty belonging to the instrument and the secondary laboratory, and follows the method estabilished by the International Organization for Standardization (ISO) and the Bureau International des Poids et Mesures (BIPM). The calibration curve is fitted by the least squares method with uncertainties in the two variables. We got an efficient instrument with uncertainties under the limits estabilished by the regulating standards [fr

  8. Global chaos synchronization of new chaotic systems via nonlinear control

    Chen, H.-K.

    2005-01-01

    Nonlinear control is an effective method for making two identical chaotic systems or two different chaotic systems be synchronized. However, this method assumes that the Lyapunov function of error dynamic (e) of synchronization is always formed as V (e) = 1/2e T e. In this paper, modification based on Lyapunov stability theory to design a controller is proposed in order to overcome this limitation. The method has been applied successfully to make two identical new systems and two different chaotic systems (new system and Lorenz system) globally asymptotically synchronized. Since the Lyapunov exponents are not required for the calculation, this method is effective and convenient to synchronize two identical systems and two different chaotic systems. Numerical simulations are also given to validate the proposed synchronization approach

  9. Chapter 5: Quality assurance/quality control in stormwater sampling

    Sampling the quality of stormwater presents unique challenges because stormwater flow is relatively short-lived with drastic variability. Furthermore, storm events often occur with little advance warning, outside conventional work hours, and under adverse weather conditions. Therefore, most stormwat...

  10. 21 CFR 111.117 - What quality control operations are required for equipment, instruments, and controls?

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What quality control operations are required for equipment, instruments, and controls? 111.117 Section 111.117 Food and Drugs FOOD AND DRUG ADMINISTRATION... and Process Control System: Requirements for Quality Control § 111.117 What quality control operations...

  11. An Austrian framework for PET quality control

    Nicoletti, R.; Dobrozemsky, G.; Minear, G.; Bergmann, H.

    2002-01-01

    Full text: The European patient protection directive (97/43 EURATOM) requires regular routine quality control (QC) of PET imaging devices. Since no standards were available covering this area and in order to comply with the directive a joint working party of the Austrian societies of nuclear medicine and of medical physics have developed a set of procedures suitable for both dedicated PET scanners and gamma cameras operating in coincidence mode (GCPET). The routine procedures proposed include both manufacturer recommended procedures and tests for specific parameters and calibration procedures. Wherever possible, procedures adapted or derived from NEMA standards publication NU 2-2001 were used to permit direct comparison with specified parameters of image quality. For dedicated PET scanners the most important procedures are the checking of detector sensitivities and the attenuation calibration scan. With full ring scanners the attenuation calibration scan is a blank scan, with partial ring devices a special attenuation calibration phantom has to be used. Test protocols are specific to manufacturer and scanner type. They are usually performed automatically overnight. In addition, some instruments require special calibrations, e.g. gain adjustments or coincidence timing calibration. GCPET procedures include the frequent assessment in coincidence mode of detector uniformity, energy resolution and system sensitivity. Common to both dedicated PET and GCPET are the regular quarterly assessment of tomographic spatial resolution and the calibration of the system for quantitative measurements. As a total performance test for both systems assessment of image quality following NU 2-2001 was included, to be carried out after major system changes or repairs. The suite of QC procedures was tested on several dedicated PET and GCPET systems including all major manufacturers' systems. Due to missing hardware or software not all tests could be performed on all systems. Some of the

  12. Quality control and characterization of bentonite materials

    Kiviranta, L.; Kumpulainen, S.

    2011-12-01

    . Thus, in a certain extent, index tests can be used to determine the smectite content indicatively for quality control purposes. Previously set acceptance testing requirement limits for swelling index, liquid limit and CEC should be reconsidered, since Ca-bentonite tested in this study did not fulfill the requirement for swelling index, the previously set liquid limit requirement value was way below the values measured in this study, and because the previously set CEC requirement limits were based on a technique that needed different requirement limits for Na- and Ca-bentonites, on contrary to the method used in this study.(orig.)

  13. 7 CFR 58.733 - Quality control tests.

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.733 Section 58.733... Procedures § 58.733 Quality control tests. (a) Chemical analyses. The following chemical analyses shall be... pasteurization by means of the phosphatase test, as well as any other tests necessary to assure good quality...

  14. Minimal requirements for quality controls in radiotherapy with external beams

    1999-01-01

    Physical dosimetric guidelines have been developed by the Italian National Institute of Health study group on quality assurance in radiotherapy to define protocols for quality controls in external beam radiotherapy. While the document does not determine strict rules or firm recommendations, it suggests minimal requirements for quality controls necessary to guarantee an adequate degree of accuracy in external beam radiotherapy [it

  15. Performance and quality control of nuclear medicine instrumentation

    Paras, P.

    1981-01-01

    The status and the recent developments of nuclear medicine instrumentation performance, with an emphasis on gamma-camera performance, are discussed as the basis for quality control. New phantoms and techniques for the measurement of gamma-camera performance parameters are introduced and their usefulness for quality control is discussed. Tests and procedures for dose calibrator quality control are included. Also, the principles of quality control, tests, equipment and procedures for each type of instrument are reviewed, and minimum requirements for an effective quality assurance programme for nuclear medicine instrumentation are suggested. (author)

  16. A uniform, quality controlled Surface Ocean CO2 Atlas (SOCAT)

    Pfeil, B.; Olsen, A; Bakker, D.C.E.; Hankin, S.; Koyuk, H.; Kozyr, A; Malczyk, J.; Manke, A; Metzl, N.; Sabine, C.L.; Akl, J.; Alin, S.R.; Bates, N.; Bellerby, R.G.J.; Borges, A; Boutin, J.; Brown, P.J.; Cai, W.-J.; Chavez, F.P.; Chen, A; Cosca, C.; Fassbender, A.J.; Feely, R.A.; Gonzalez-Davila, M.; Goyet, C.; Hales, B.; Hardman-Mountford, N.; Heinze, C.; Hood, M.; Hoppema, M.; Hunt, C.W.; Hydes, D.; Ishii, M.; Johannessen, T.; Jones, S.D.; Key, R.M.; Kortzinger, A.; Landschutzer, P.; Lauvset, S.K.; Lefevre, N.; Lenton, A.; Lourantou, A.; Merlivat, L.; Midorikawa, T.; Mintrop, L.; Miyazaki, C.; Murata, A.; Nakadate, A.; Nakano, Y.; Nakaoka, S.; Nojiri, Y.; Omar, A.M.; Padin, X.A.; Park, G.-H.; Paterson, K.; Perez, F.F.; Pierrot, D.; Poisson, A.; Rios, A.F.; Santana-Casiano, J.M.; Salisbury, J.; Sarma, V.V.S.S.; et al

    by the international marine carbon science community in 2007 with the aim of providing a comprehensive, publicly available, regularly updated, global data set of marine surface CO2, which had been subject to quality control (QC). Many additional CO2 data, not yet made...

  17. Transport of Aerosols: Regional and Global Implications for Climate, Weather, and Air Quality

    Chin, Mian; Diehl, Thomas; Yu, Hongbin; Bian, Huisheng; Remer, Lorraine; Kahn, Ralph

    2008-01-01

    Long-range transport of atmospheric aerosols can have a significant impact on global climate, regional weather, and local air quality. In this study, we use a global model GOCART together with satellite data and ground-based measurements to assess the emission and transport of pollution, dust, biomass burning, and volcanic aerosols and their implications. In particular, we will show the impact of emissions and long-range transport of aerosols from major pollution and dust source regions to (1) the surface air quality, (2) the atmospheric heating rates, and (3) surface radiation change near the source and downwind regions.

  18. 10 CFR 26.167 - Quality assurance and quality control.

    2010-01-01

    ... at the appropriate cutoff concentration for the compound of interest as specified in § 26.161(c) and (f), a control without the compound of interest (i.e., a certified negative control), and at least one control with one of the compounds of interest at a measurable concentration; and (ii) A...

  19. Global voltage control for the LEP RF system

    Ciapala, E.; Butterworth, A.; Peschardt, E.

    1993-01-01

    The LEG RF system is installed as independent 16 cavity units. In addition to the eight copper cavity units originally installed 12 units with super-conducting cavities are being added for the LEP200 energy upgrade. The total RF voltage determines the synchrotron tune (Qs) and must be controlled precisely during energy ramping. Local function generators in each of the RF units are pre-loaded such that when triggered simultaneously by ramp timing events transmitted over the general timing system the total voltage varies to give the Qs function required. A disadvantage is that loss of RF in a unit at any time after the loading process cannot be corrected. As the number of RF units increases automatic control of the total RF voltage and its distribution around LEP becomes desirable. A global voltage control system, based on a central VME controller, has recently been installed. It has direct and rapid access to the RF units over the LEP time division multiplexing system. Initial tests on operation and performance at fixed energy and during energy ramping are described, as well as the implementation of a Qs loop in which Qs can be set directly using on-line synchrotron frequency measurements

  20. Performance of Globally Linearized Controller and Two Region Fuzzy Logic Controller on a Nonlinear Process

    N. Jaya

    2008-10-01

    Full Text Available In this work, a design and implementation of a Conventional PI controller, single region fuzzy logic controller, two region fuzzy logic controller and Globally Linearized Controller (GLC for a two capacity interacting nonlinear process is carried out. The performance of this process using single region FLC, two region FLC and GLC are compared with the performance of conventional PI controller about an operating point of 50 %. It has been observed that GLC and two region FLC provides better performance. Further, this procedure is also validated by real time experimentation using dSPACE.

  1. SALE, Quality Control of Analytical Chemical Measurements

    Bush, W.J.; Gentillon, C.D.

    1985-01-01

    1 - Description of problem or function: The Safeguards Analytical Laboratory Evaluation (SALE) program is a statistical analysis program written to analyze the data received from laboratories participating in the SALE quality control and evaluation program. The system is aimed at identifying and reducing analytical chemical measurement errors. Samples of well-characterized materials are distributed to laboratory participants at periodic intervals for determination of uranium or plutonium concentration and isotopic distributions. The results of these determinations are statistically evaluated and participants are informed of the accuracy and precision of their results. 2 - Method of solution: Various statistical techniques produce the SALE output. Assuming an unbalanced nested design, an analysis of variance is performed, resulting in a test of significance for time and analyst effects. A trend test is performed. Both within- laboratory and between-laboratory standard deviations are calculated. 3 - Restrictions on the complexity of the problem: Up to 1500 pieces of data for each nuclear material sampled by a maximum of 75 laboratories may be analyzed

  2. Quality control chart for crushed granite concrete

    Ewa E. DESMOND

    2016-07-01

    Full Text Available A chart for assessing in-situ grade (strength of concrete, has been developed in this study. Four grades of concrete after the Nigerian General Specification for Roads and bridges (NGSRB-C20, C25, C30 and C35, is studied at different water-cement ratios for medium and high slump range. The concrete mixes are made from crushed granite rock as coarse aggregate with river sand as fine aggregate. Compression test on specimens are conducted at curing age of 1, 3, 7, 14, 21, 28 and 56 days. Results on concrete workability from slump values, and water-cement ratios revealed that specimens with lower water-cement ratio were less workable but had higher strength, compared to mixes with higher water cement ratio. A simple algorithm using nonlinear regression analysis performed on each experimental data set produced Strength-Age (S-A curves which were used to establish a quality control chart. The accuracy of these curves were evaluated by computing average absolute error (AAS, the error of estimate (EoE and the average absolute error of estimate (Abs EoE for each concrete mix. These were done based on the actual average experimental strengths to measure how close the predicted values are to the experimental data set. The absolute average error of estimate (Abs. EoE recorded was less than ±10% tolerance zone for concrete works.

  3. The IAEA's programme in analytical quality control

    Suschny, O.

    1980-10-01

    The purpose of the Analytical Quality Control Programme of the International Atomic Energy Agency is to help laboratories in the Agency's Member States to assess and, if necessary, to improve the reliability of their analytical work in areas related to nuclear technology and radioisotope utilisation. This is done by the organisation of analytical intercomparisons and by the provision of certified or uncertified reference materials. Recently intercomparisons have been organised of trace element analysis in a soil and a lake sediment sample which have led to the certification of two new reference materials, SOIL-5 and SL-1 (lake sediment). A technique has been developed to recognise and to remove outlying results. Criteria have been established to classify element-concentration values into the categories ''established with a high degree of confidence'', ''established with a reasonable degree of confidence'' and ''information value only''. Four radionuclide intercomparisons have recently been carried out: W-1/1 and W-2/1 of the determination of selected radionuclides in water and Air-1/1 and Air-2/1 of that of selected radionuclides on simulated air filters. Details of the preparation of materials for these intercomparisons, and of data treatment and some results are discussed in the paper

  4. The quality control theory of aging

    Warren Ladiges

    2014-05-01

    Full Text Available The quality control (QC theory of aging is based on the concept that aging is the result of a reduction in QC of cellular systems designed to maintain lifelong homeostasis. Four QC systems associated with aging are 1 inadequate protein processing in a distressed endoplasmic reticulum (ER; 2 histone deacetylase (HDAC processing of genomic histones and gene silencing; 3 suppressed AMPK nutrient sensing with inefficient energy utilization and excessive fat accumulation; and 4 beta-adrenergic receptor (BAR signaling and environmental and emotional stress. Reprogramming these systems to maintain efficiency and prevent aging would be a rational strategy for increased lifespan and improved health. The QC theory can be tested with a pharmacological approach using three well-known and safe, FDA-approved drugs: 1 phenyl butyric acid, a chemical chaperone that enhances ER function and is also an HDAC inhibitor, 2 metformin, which activates AMPK and is used to treat type 2 diabetes, and 3 propranolol, a beta blocker which inhibits BAR signaling and is used to treat hypertension and anxiety. A critical aspect of the QC theory, then, is that aging is associated with multiple cellular systems that can be targeted with drug combinations more effectively than with single drugs. But more importantly, these drug combinations will effectively prevent, delay, or reverse chronic diseases of aging that impose such a tremendous health burden on our society.

  5. The quality control theory of aging.

    Ladiges, Warren

    2014-01-01

    The quality control (QC) theory of aging is based on the concept that aging is the result of a reduction in QC of cellular systems designed to maintain lifelong homeostasis. Four QC systems associated with aging are 1) inadequate protein processing in a distressed endoplasmic reticulum (ER); 2) histone deacetylase (HDAC) processing of genomic histones and gene silencing; 3) suppressed AMPK nutrient sensing with inefficient energy utilization and excessive fat accumulation; and 4) beta-adrenergic receptor (BAR) signaling and environmental and emotional stress. Reprogramming these systems to maintain efficiency and prevent aging would be a rational strategy for increased lifespan and improved health. The QC theory can be tested with a pharmacological approach using three well-known and safe, FDA-approved drugs: 1) phenyl butyric acid, a chemical chaperone that enhances ER function and is also an HDAC inhibitor, 2) metformin, which activates AMPK and is used to treat type 2 diabetes, and 3) propranolol, a beta blocker which inhibits BAR signaling and is used to treat hypertension and anxiety. A critical aspect of the QC theory, then, is that aging is associated with multiple cellular systems that can be targeted with drug combinations more effectively than with single drugs. But more importantly, these drug combinations will effectively prevent, delay, or reverse chronic diseases of aging that impose such a tremendous health burden on our society.

  6. Quality control culture of diagnostic ultrasound parameters

    Andam, A.A.B; Addison, E.C.K.; Aggry-Smith, S.; Nani, E.K.

    2003-01-01

    A phantom, consisting of two phases, has been designed and constructed to mimic the human body. The phase one phantom was designed to mimic a a surface lesion in the human body and the phase two phantom designed to mimic a section of the whole body. Ultrasound scans of the phantom were acquired for various material in the phantom at six hospitals in Kumasi, Ghana. A linear array transducer with parallel beams having a convex probe and a 3.5 MHz ultrasound frequency were used to carry out the experiment. It was observed that the depth of penetration of ultrasound, which constitutes the maximum depth of visualization or sensitivity, is determined by the frequency of the transducer, the attenuation of the medium being imaged and the system settings. Uniformity and linearity of the machines investigated were found to be within clinically acceptable standards. Spatial resolution, comprising axial and lateral resolutions, was observed to be satisfactory for the machines tested. It was observed that lateral resolution improved with the narrowing of the beam width. The ultrasound scanners at the selected hospitals were found to be operating at the expected level of performance. This work highlights the importance of putting in place a locally based mechanism for quality control of diagnostic ultrasound machines (author)

  7. QUALITY CONTROL OF SOME TRADITIONAL MEAT PRODUCTS

    S. DOBRINAS

    2014-03-01

    Full Text Available In this paper, we present the characterization of six traditional meat products: smoked file, smoked bacon, pork sausages, sausage prepared from swine’s entrails, pork pastrami, sheep sausages. Organoleptic tests (the aspect and shape, the aspect of freshly cut in the section, smell, taste and consistency, physico-chemical and microbiological determinations (NTG, Salmonella, Listeria monocytogenes and Escherichia coli were performed. These analyzes are a part of quality control that must be done in order to obtain a certificate from the Ministry of Agriculture for a traditional product. After identification of H2S and starch and according to fat oxidation degree it was concluded that analyzed samples didn’t contain counterfeiters and all parameters analyzed are within the maximum limits allowed by law. Considering all the procedures for manufacturing, characteristics of raw and auxiliary materials, organoleptic properties of final products analyzed in this study, it can be concluded that analyzed meat specialties meet the requirements of Ministry Order no. 690/28.09.2004 for the traditional products certification.

  8. Bacterial lipoproteins; biogenesis, sorting and quality control.

    Narita, Shin-Ichiro; Tokuda, Hajime

    2017-11-01

    Bacterial lipoproteins are a subset of membrane proteins localized on either leaflet of the lipid bilayer. These proteins are anchored to membranes through their N-terminal lipid moiety attached to a conserved Cys. Since the protein moiety of most lipoproteins is hydrophilic, they are expected to play various roles in a hydrophilic environment outside the cytoplasmic membrane. Gram-negative bacteria such as Escherichia coli possess an outer membrane, to which most lipoproteins are sorted. The Lol pathway plays a central role in the sorting of lipoproteins to the outer membrane after lipoprotein precursors are processed to mature forms in the cytoplasmic membrane. Most lipoproteins are anchored to the inner leaflet of the outer membrane with their protein moiety in the periplasm. However, recent studies indicated that some lipoproteins further undergo topology change in the outer membrane, and play critical roles in the biogenesis and quality control of the outer membrane. This article is part of a Special Issue entitled: Bacterial Lipids edited by Russell E. Bishop. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Global modelling of magnetic island control in tokamaks

    Fevrier, Olivier

    2016-01-01

    Magneto-Hydro-Dynamic (MHD) instabilities are susceptible to develop within a tokamak plasma. These instabilities manifest themselves as magnetic islands which reduce the plasma confinement. The islands can however be controlled by driving current inside them. In this thesis, we consider the modeling of the magnetic islands and their control using first principle approaches, which rely on a global MHD description of the plasma. We have detailed the inclusion a RF-driven current like source term in an MHD code, which requires special care to be given to the modeling of the current density evolution. The implementation has been benchmarked against the asymptotic models, allowing us to retrieve the influence of parameters such as deposition width or misalignment with respect to the island width and position. Beyond these aspects, we have evidenced new effects, linked to the 3D nature of the current deposition. We have observed a flip instability in which an island, reduced by the ECCD, brutally inverse its phase so that its X-Point faces the current deposition, allowing the mode the grow further. We then moved on to the topic of the best suitable control strategies for the control of the island. We have implemented in XTOR a control system that mimics the experimental ones and adapt the current deposition in function of a preset strategy. Nonlinear MHD simulations have been carried out using different control schemes, allowing us to quantify the gain to expect from each of these methods depending on the characteristics of the current deposition. (author) [fr

  10. Quality assurance and quality control of nuclear analytical techniques

    Cincu, Emanuelathor

    2001-01-01

    Test and analytical laboratories in East and Central European countries need to prove the reliability and credibility of their economic, environmental, medical and legal decisions and their capacity of issuing reliable, verifiable reports. These demands imposed by the European Union aimed at avoiding a possible barrier to trade for the developing countries. In June 1999, in order to help Member States to develop according to EU objectives and the overall situation of the European market, IAEA launched a new co-operation programme designed to help the nuclear analytical laboratories in nuclear institutions and universities of Member States by training in the use of some Nuclear Analytical Techniques (NAT) that include: alpha, beta and gamma-ray spectrometry, radiochemical and neutron activation analysis, total reflection X-ray fluorescence. The Regional IAEA Project, named 'Quality Assurance/Quality Control of Nuclear Analytical Techniques' (NAT) aims at implementing the QA principles via a system of defined consecutive steps leading to a level on which the QA system is self-sustainable for formal accreditation or certification and satisfies the EU technical performance criteria; the requirements are in accordance with the new ISO/IEC 17025 Standard/Dec.1999 'General requirements for the competence of testing and calibration laboratories' - First edition. The Horia Hulubei National Institute for Nuclear Physics and Engineering, IFIN-HH, was admitted for participation in the IAEA Project in June 1999 account taken of its experience in the QA and metrology fields and its performance in the fields of beta and gamma-ray spectrometry, and radiochemical and neutron activation analysis, employed in both basic research and applications for external clients. Two working groups of specialists with the QA and Standardization and Metrology Departments and six analytical groups with the departments of Nuclear Applied Physics, Life Physics and Ionising Radiation Metrology are

  11. Mitochondrial quality control pathways as determinants of metabolic health

    Held, Ntsiki M.; Houtkooper, Riekelt H.

    2015-01-01

    Mitochondrial function is key for maintaining cellular health, while mitochondrial failure is associated with various pathologies, including inherited metabolic disorders and age-related diseases. In order to maintain mitochondrial quality, several pathways of mitochondrial quality control have

  12. Concrete and steel construction quality control and assurance

    El-Reedy, Mohamed A

    2014-01-01

    Starting with the receipt of materials and continuing all the way through to the final completion of the construction phase, Concrete and Steel Construction: Quality Control and Assurance examines all the quality control and assurance methods involving reinforced concrete and steel structures. This book explores the proper ways to achieve high-quality construction projects, and also provides a strong theoretical and practical background. It introduces information on quality techniques and quality management, and covers the principles of quality control. The book presents all of the quality control and assurance protocols and non-destructive test methods necessary for concrete and steel construction projects, including steel materials, welding and mixing, and testing. It covers welding terminology and procedures, and discusses welding standards and procedures during the fabrication process, as well as the welding codes. It also considers the total quality management system based on ISO 9001, and utilizes numer...

  13. Accelerating the Global Nested Air Quality Prediction Modeling System (GNAQPMS) model on Intel Xeon Phi processors

    Wang, Hui; Chen, Huansheng; Wu, Qizhong; Lin, Junming; Chen, Xueshun; Xie, Xinwei; Wang, Rongrong; Tang, Xiao; Wang, Zifa

    2017-01-01

    The GNAQPMS model is the global version of the Nested Air Quality Prediction Modelling System (NAQPMS), which is a multi-scale chemical transport model used for air quality forecast and atmospheric environmental research. In this study, we present our work of porting and optimizing the GNAQPMS model on the second generation Intel Xeon Phi processor codename “Knights Landing” (KNL). Compared with the first generation Xeon Phi coprocessor, KNL introduced many new hardware features such as a boo...

  14. A Satellite-Based Multi-Pollutant Index of Global Air Quality

    Cooper, Mathew J.; Martin, Randall V.; vanDonkelaar, Aaron; Lamsal, Lok; Brauer, Michael; Brook, Jeffrey R.

    2012-01-01

    Air pollution is a major health hazard that is responsible formillions of annual excess deaths worldwide. Simpleindicators are useful for comparative studies and to asses strends over time. The development of global indicators hasbeen impeded by the lack of ground-based observations in vast regions of the world. Recognition is growing of the need for amultipollutant approach to air quality to better represent human exposure. Here we introduce the prospect of amultipollutant air quality indicator based on observations from satellite remote sensing.

  15. Descriptive study of the quality control in mammography

    Gaona, E.; Perdigon C, G.M.; Casian C, G.A.; Azorin N, J.; Diaz G, J.A.I.; Arreola, M.

    2005-01-01

    The goal of mammography is to provide contrast between a lesion that is possible residing within the breast and normal surrounding tissue. Quality control is essential for maintaining the contrast imaging performance of a mammography system and incorporate tests that are relevant in that they are predictive of future degradation of contrast imaging performance. These tests will also be done at frequency that is high enough to intercept most drifts in quality imaging or performance before they become diagnostically significant. The quality control study has as objective to describe the results of the assessment of quality imaging elements (film optical density, contrast (density difference), uniformity, resolution and noise) of 62 mammography departments without quality control program and comparison these results with a mammography reference department with a quality control program. When comparing the results they allow seeing the clinical utility of to have a quality control program to reduce the errors of mammography interpretation. (Author)

  16. Climate Controls AM Fungal Distributions from Global to Local Scales

    Kivlin, S. N.; Hawkes, C.; Muscarella, R.; Treseder, K. K.; Kazenel, M.; Lynn, J.; Rudgers, J.

    2016-12-01

    Arbuscular mycorrhizal (AM) fungi have key functions in terrestrial biogeochemical processes; thus, determining the relative importance of climate, edaphic factors, and plant community composition on their geographic distributions can improve predictions of their sensitivity to global change. Local adaptation by AM fungi to plant hosts, soil nutrients, and climate suggests that all of these factors may control fungal geographic distributions, but their relative importance is unknown. We created species distribution models for 142 AM fungal taxa at the global scale with data from GenBank. We compared climate variables (BioClim and soil moisture), edaphic variables (phosphorus, carbon, pH, and clay content), and plant variables using model selection on models with (1) all variables, (2) climatic variables only (including soil moisture) and (3) resource-related variables only (all other soil parameters and NPP) using the MaxEnt algorithm evaluated with ENMEval. We also evaluated whether drivers of AM fungal distributions were phylogenetically conserved. To test whether global correlates of AM fungal distributions were reflected at local scales, we then surveyed AM fungi in nine plant hosts along three elevation gradients in the Upper Gunnison Basin, Colorado, USA. At the global scale, the distributions of 55% of AM fungal taxa were affected by both climate and soil resources, whereas 16% were only affected by climate and 29% were only affected by soil resources. Even for AM fungi that were affected by both climate and resources, the effects of climatic variables nearly always outweighed those of resources. Soil moisture and isothermality were the main climatic and NPP and soil carbon the main resource related factors influencing AM fungal distributions. Distributions of closely related AM fungal taxa were similarly affected by climate, but not by resources. Local scale surveys of AM fungi across elevations confirmed that climate was a key driver of AM fungal

  17. Analytical approaches to quality assurance and quality control in rangeland monitoring data

    Producing quality data to support land management decisions is the goal of every rangeland monitoring program. However, the results of quality assurance (QA) and quality control (QC) efforts to improve data quality are rarely reported. The purpose of QA and QC is to prevent and describe non-sampling...

  18. Title IV Quality Control Project, Stage II. Management Option II: Delivery System Quality Improvements.

    Advanced Technology, Inc., Reston, VA.

    Stage Two of the Title IV Quality Control Project is an integrated study of quality in five related Federal financial aid programs for postsecondary students. Section 1 of the paper establishes a framework for defining quality improvements, in order to identify the types of changes that would tend to improve quality across all facets of the…

  19. 7 CFR 58.442 - Laboratory and quality control tests.

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.442 Section... Service 1 Operations and Operating Procedures § 58.442 Laboratory and quality control tests. (a) Chemical... Methods or by other methods giving equivalent results. (b) Weight or volume control. Representative...

  20. Forty years of improvements in European air quality: regional policy-industry interactions with global impacts

    M. Crippa

    2016-03-01

    role that technology has played in reducing emissions in 2010. However, stagnation of energy consumption at 1970 levels, but with 2010 fuel mix and energy efficiency, and assuming current (year 2010 technology and emission control standards, would have lowered today's NOx emissions by ca. 38 %, SO2 by 50 % and PM2.5 by 12 % in Europe. A reduced-form chemical transport model is applied to calculate regional and global levels of aerosol and ozone concentrations and to assess the associated impact of air quality improvements on human health and crop yield loss, showing substantial impacts of EU technologies and standards inside as well as outside Europe. We assess that the interplay of policy and technological advance in Europe had substantial benefits in Europe, but also led to an important improvement of particulate matter air quality in other parts of the world.

  1. Introduction to Quality Control in a Compounding Pharmacy.

    Allen, Loyd V

    2016-01-01

    A quality-based program is vital in every compounding pharmacy to ensure that each preparation is compounded properly and is stable for its expected duration of use. This article discusses quality control, quality assurance, continuous quality improvement, and also describes the components of an in-house (in-pharmacy) quality program, as well as the role of outside laboratories. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  2. Implementing self sustained quality control procedures in a clinical laboratory.

    Khatri, Roshan; K C, Sanjay; Shrestha, Prabodh; Sinha, J N

    2013-01-01

    Quality control is an essential component in every clinical laboratory which maintains the excellence of laboratory standards, supplementing to proper disease diagnosis, patient care and resulting in overall strengthening of health care system. Numerous quality control schemes are available, with combinations of procedures, most of which are tedious, time consuming and can be "too technical" whereas commercially available quality control materials can be expensive especially for laboratories in developing nations like Nepal. Here, we present a procedure performed at our centre with self prepared control serum and use of simple statistical tools for quality assurance. The pooled serum was prepared as per guidelines for preparation of stabilized liquid quality control serum from human sera. Internal Quality Assessment was performed on this sample, on a daily basis which included measurement of 12 routine biochemical parameters. The results were plotted on Levey-Jennings charts and analysed with quality control rules, for a period of one month. The mean levels of biochemical analytes in self prepared control serum were within normal physiological range. This serum was evaluated every day along with patients' samples. The results obtained were plotted on control charts and analysed using common quality control rules to identify possible systematic and random errors. Immediate mitigation measures were taken and the dispatch of erroneous reports was avoided. In this study we try to highlight on a simple internal quality control procedure which can be performed by laboratories, with minimum technology, expenditure, and expertise and improve reliability and validity of the test reports.

  3. Methods for the Quality Control of Inactivated Poliovirus Vaccines.

    Wilton, Thomas

    2016-01-01

    Inactivated poliovirus vaccine (IPV) plays an instrumental role in the Global Poliovirus Eradication Initiative (GPEI). The quality of IPV is controlled by assessment of the potency of vaccine batches. The potency of IPV can be assessed by both in vivo and in vitro methods. In vitro potency assessment is based upon the assessment of the quantity of the D-Antigen (D-Ag) units in an IPV. The D-Ag unit is used as a measure of potency as it is largely expressed on native infectious virions and is the protective immunogen. The most commonly used in vitro test is the indirect ELISA which is used to ensure consistency throughout production.A range of in vivo assays have been developed in monkeys, chicks, guinea pigs, mice, and rats to assess the potency of IPV. All are based on assessment of the neutralizing antibody titer within the sera of the respective animal model. The rat potency test has become the favored in vivo potency test as it shows minimal variation between laboratories and the antibody patterns of rats and humans are similar. With the development of transgenic mice expressing the human poliovirus receptor, immunization-challenge tests have been developed to assess the potency of IPVs. This chapter describes in detail the methodology of these three laboratory tests to assess the quality of IPVs.

  4. The results of a quality-control programme in mammography

    Ramsdale, M.L.; Hiles, P.A.

    1989-01-01

    With the introduction of a breast screening programme in the UK, quality assurance in mammography is of paramount importance in assuring optimum imaging performance with low dose. Quality control checks are an essential part of the quality-assurance system. A quality-control programme at a breast screening clinic is described. Daily checks include film sensitometry for X-ray processor control and radiography of a lucite phantom to monitor the consistency of the X-ray machine automatic exposure control. Weekly checks include additional measurements on the performance of the automatic exposure control for different breast thickness and an overall assessment of image quality using a prototype mammography test phantom. The test phantom measures low-contrast sensitivity, high-contrast resolution and small-detail visibility. The results of the quality-control programme are presented with particular attention paid to tolerances and limiting values. (author)

  5. Quality control with R an ISO standards approach

    Cano, Emilio L; Prieto Corcoba, Mariano

    2015-01-01

    Presenting a practitioner's guide to capabilities and best practices of quality control systems using the R programming language, this volume emphasizes accessibility and ease-of-use through detailed explanations of R code as well as standard statistical methodologies. In the interest of reaching the widest possible audience of quality-control professionals and statisticians, examples throughout are structured to simplify complex equations and data structures, and to demonstrate their applications to quality control processes, such as ISO standards. The volume balances its treatment of key aspects of quality control, statistics, and programming in R, making the text accessible to beginners and expert quality control professionals alike. Several appendices serve as useful references for ISO standards and common tasks performed while applying quality control with R.

  6. Parallel processing and non-uniform grids in global air quality modeling

    Berkvens, P.J.F.; Bochev, Mikhail A.

    2002-01-01

    A large-scale global air quality model, running efficiently on a single vector processor, is enhanced to make more realistic and more long-term simulations feasible. Two strategies are combined: non-uniform grids and parallel processing. The communication through the hierarchy of non-uniform grids

  7. Preparing the Model for Prediction Across Scales (MPAS) for global retrospective air quality modeling

    The US EPA has a plan to leverage recent advances in meteorological modeling to develop a "Next-Generation" air quality modeling system that will allow consistent modeling of problems from global to local scale. The meteorological model of choice is the Model for Predic...

  8. The Water Quality in Rio Highlights the Global Public Health Concern Over Untreated Sewage Disposal

    Water quality issues in Rio have been widely publicized because of the 2016 Olympics. Recent concerns about polluted waters that athletes may be exposed to highlights the conditions that more than a billion people globally are exposed to daily. Despite these unhealthy conditions,...

  9. Exploring the Relationship between Global Quality and Group Engagement in Toddler Child Care Classrooms

    Hooper, Alison; Hallam, Rena

    2017-01-01

    Toddlers' engagement with their social and physical environment is an important aspect of their experience in early care and education programs. The purpose of this research study was to examine how global quality relates to children's engagement in toddler child care classrooms. Additionally, this study explored how toddlers' group engagement…

  10. 42 CFR 84.256 - Quality control requirements.

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Quality control requirements. 84.256 Section 84.256... § 84.256 Quality control requirements. (a) In addition to the construction and performance requirements specified in §§ 84.251, 84.252, 84.253, 84.254, and 84.255, the quality control requirements in paragraphs...

  11. Internal quality control of RIA with Tonks error calculation method

    Chen Xiaodong

    1996-01-01

    According to the methodology feature of RIA, an internal quality control chart with Tonks error calculation method which is suitable for RIA is designed. The quality control chart defines the value of the allowance error with normal reference range. The method has the simplicity of its performance and directly perceived through the senses. Taking the example of determining T 3 and T 4 , the calculation of allowance error, drawing of quality control chart and the analysis of result are introduced

  12. Proteomics Quality Control: Quality Control Software for MaxQuant Results.

    Bielow, Chris; Mastrobuoni, Guido; Kempa, Stefan

    2016-03-04

    Mass spectrometry-based proteomics coupled to liquid chromatography has matured into an automatized, high-throughput technology, producing data on the scale of multiple gigabytes per instrument per day. Consequently, an automated quality control (QC) and quality analysis (QA) capable of detecting measurement bias, verifying consistency, and avoiding propagation of error is paramount for instrument operators and scientists in charge of downstream analysis. We have developed an R-based QC pipeline called Proteomics Quality Control (PTXQC) for bottom-up LC-MS data generated by the MaxQuant software pipeline. PTXQC creates a QC report containing a comprehensive and powerful set of QC metrics, augmented with automated scoring functions. The automated scores are collated to create an overview heatmap at the beginning of the report, giving valuable guidance also to nonspecialists. Our software supports a wide range of experimental designs, including stable isotope labeling by amino acids in cell culture (SILAC), tandem mass tags (TMT), and label-free data. Furthermore, we introduce new metrics to score MaxQuant's Match-between-runs (MBR) functionality by which peptide identifications can be transferred across Raw files based on accurate retention time and m/z. Last but not least, PTXQC is easy to install and use and represents the first QC software capable of processing MaxQuant result tables. PTXQC is freely available at https://github.com/cbielow/PTXQC .

  13. Quality of Life Theory I. The IQOL Theory: An Integrative Theory of the Global Quality of Life Concept

    Soren Ventegodt

    2003-01-01

    Full Text Available Quality of life (QOL means a good life and we believe that a good life is the same as living a life with a high quality. This paper presents the theoretical and philosophical framework of the Danish Quality of Life Survey, and of the SEQOL, QOL5, and QOL1 questionnaires.The notion of a good life can be observed from subjective to the objective, where this spectrum incorporates a number of existing quality of life theories. We call this spectrum the integrative quality-of-life (IQOL theory and discuss the following aspects in this paper: well being, satisfaction with life, happiness, meaning in life, the biological information system (�balance�, realizing life potential, fulfillment of needs, and objective factors.The philosophy of life outlined in this paper tries to measure the global quality of life with questions derived from the integrative theory of the quality of life. The IQOL theory is an overall theory or meta-theory encompassing eight more factual theories in a subjective-existential-objective spectrum. Other philosophies of life can stress other aspects of life, but by this notion of introducing such an existential depth into the health and social sciences, we believe to have taken a necessary step towards a new humility and respect for the richness and complexity of life.

  14. A Total Quality-Control Plan with Right-Sized Statistical Quality-Control.

    Westgard, James O

    2017-03-01

    A new Clinical Laboratory Improvement Amendments option for risk-based quality-control (QC) plans became effective in January, 2016. Called an Individualized QC Plan, this option requires the laboratory to perform a risk assessment, develop a QC plan, and implement a QC program to monitor ongoing performance of the QC plan. Difficulties in performing a risk assessment may limit validity of an Individualized QC Plan. A better alternative is to develop a Total QC Plan including a right-sized statistical QC procedure to detect medically important errors. Westgard Sigma Rules provides a simple way to select the right control rules and the right number of control measurements. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. The results of a quality-control programme in mammography

    Ramsdale, M.L.; Hiles, P.A.

    1989-01-01

    A quality-control programme at a breast screening clinic is described. Daily checks include film sensitometry for X-ray processor control and radiography of a lucite phantom to monitor the consistency of the X-ray machine automatic exposure control. Weekly checks include additional measurements on the performance of the automatic exposure control for different breast thickness and an overall assessment of image quality using a prototype mammography test phantom. The test phantom measures low-contrast sensitivity, high-control resolution and small-detail visibility. The results of the quality-control programme are presented with particular attention paid to tolerances and limiting values. (author)

  16. General Quality Control (QC) Guidelines for SAM Methods

    Learn more about quality control guidelines and recommendations for the analysis of samples using the methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  17. Intra- and Intercellular Quality Control Mechanisms of Mitochondria

    Yoshimitsu Kiriyama

    2017-12-01

    Full Text Available Mitochondria function to generate ATP and also play important roles in cellular homeostasis, signaling, apoptosis, autophagy, and metabolism. The loss of mitochondrial function results in cell death and various types of diseases. Therefore, quality control of mitochondria via intra- and intercellular pathways is crucial. Intracellular quality control consists of biogenesis, fusion and fission, and degradation of mitochondria in the cell, whereas intercellular quality control involves tunneling nanotubes and extracellular vesicles. In this review, we outline the current knowledge on the intra- and intercellular quality control mechanisms of mitochondria.

  18. Quality control system response to stochastic growth of amyloid fibrils

    Pigolotti, S.; Lizana, L.; Sneppen, K.

    2013-01-01

    We introduce a stochastic model describing aggregation of misfolded proteins and degradation by the protein quality control system in a single cell. Aggregate growth is contrasted by the cell quality control system, that attacks them at different stages of the growth process, with an efficiency...... that decreases with their size. Model parameters are estimated from experimental data. Two qualitatively different behaviors emerge: a homeostatic state, where the quality control system is stable and aggregates of large sizes are not formed, and an oscillatory state, where the quality control system...

  19. Globally linearized control on diabatic continuous stirred tank reactor: a case study.

    Jana, Amiya Kumar; Samanta, Amar Nath; Ganguly, Saibal

    2005-07-01

    This paper focuses on the promise of globally linearized control (GLC) structure in the realm of strongly nonlinear reactor system control. The proposed nonlinear control strategy is comprised of: (i) an input-output linearizing state feedback law (transformer), (ii) a state observer, and (iii) an external linear controller. The synthesis of discrete-time GLC controller for single-input single-output diabatic continuous stirred tank reactor (DCSTR) has been studied first, followed by the synthesis of feedforward/feedback controller for the same reactor having dead time in process as well as in disturbance. Subsequently, the multivariable GLC structure has been designed and then applied on multi-input multi-output DCSTR system. The simulation study shows high quality performance of the derived nonlinear controllers. The better-performed GLC in conjunction with reduced-order observer has been compared with the conventional proportional integral controller on the example reactor and superior performance has been achieved by the proposed GLC control scheme.

  20. The study on quality control of bedside CR examination

    Yang Xufeng; Luo Xiaomei; Xu Qiaolan; Wu Tengfang; Wen Xingwei

    2007-01-01

    Objective: To study the quality controll of bedside CR examination and improves the imaging quality. Methods: X-ray examination with CR system were performed on 3,300 patients. All CR cassettes were encoded. The imaging plate and cassettes were cleaned regularly. Results: With and without quality control, the percentage of first-rate film was 58.2% and 51%, the second-rate film was 40% and 45.5%, the third-rate film was 1.3% and 2%, respectively. Corxespondingly, the ratio of re-examination decreased from 1.5% to 0.5% after quality control, and imaging quality was stable. Conclusion: The quality control of bedside CR examination can improve the image quality as well as lighten the labor of radiographers. (authors)

  1. Secondary Control for Voltage Quality Enhancement in Microgrids

    Savaghebi, Mehdi; Jalilian, Alireza; Vasquez, Juan Carlos

    2012-01-01

    In this paper, a hierarchical control scheme is proposed for enhancement of sensitive load bus (SLB) voltage quality in microgrids. The control structure consists of primary and secondary levels. The primary control level comprises distributed generators (DGs) local controllers. Each of these con......In this paper, a hierarchical control scheme is proposed for enhancement of sensitive load bus (SLB) voltage quality in microgrids. The control structure consists of primary and secondary levels. The primary control level comprises distributed generators (DGs) local controllers. Each...

  2. Teaching Quality Control with Chocolate Chip Cookies

    Baker, Ardith

    2014-01-01

    Chocolate chip cookies are used to illustrate the importance and effectiveness of control charts in Statistical Process Control. By counting the number of chocolate chips, creating the spreadsheet, calculating the control limits and graphing the control charts, the student becomes actively engaged in the learning process. In addition, examining…

  3. Strategies for ensuring global consistency/comparability of water-quality data

    Klein, J.M.

    1999-01-01

    In the past 20 years the water quality of the United States has improved remarkably-the waters are safer for drinking, swimming, and fishing. However, despite many accomplishments, it is still difficult to answer such basic questions as: 'How clean is the water?' and 'How is it changing over time?' These same questions exist on a global scale as well. In order to focus water-data issues in the United States, a national Intergovernmental Task Force on Monitoring Water Quality (ITFM) was initiated for public and private organizations, whereby key elements involved in data collection, analysis, storage, and management could be made consistent and comparable. The ITFM recommended and its members are implementing a nationwide strategy to improve water-quality monitoring, assessment, and reporting activities. The intent of this paper is to suggest that a voluntary effort be initiated to ensure the comparability and utility of hydrological data on a global basis. Consistent, long-term data sets that are comparable are necessary in order to formulate ideas regarding regional and global trends in water quantity and quality. The author recommends that a voluntary effort similar to the ITFM effort be utilized. The strategy proposed would involve voluntary representation from countries and international organizations (e.g. World Health Organization) involved in drinking-water assessments and/or ambient water-quality monitoring. Voluntary partnerships such as this will improve curability to reduce health risks and achieve a better return on public and private investments in monitoring, environmental protection, and natural resource management, and result in a collaborative process that will save millions of dollars.In this work it is suggested that a voluntary effort be initiated to ensure the comparability and utility of hydrological data on a global basis. The strategy proposed would involve voluntary representation from countries and international organizations involved in

  4. Quality-control design for surface-water sampling in the National Water-Quality Network

    Riskin, Melissa L.; Reutter, David C.; Martin, Jeffrey D.; Mueller, David K.

    2018-04-10

    The data-quality objectives for samples collected at surface-water sites in the National Water-Quality Network include estimating the extent to which contamination, matrix effects, and measurement variability affect interpretation of environmental conditions. Quality-control samples provide insight into how well the samples collected at surface-water sites represent the true environmental conditions. Quality-control samples used in this program include field blanks, replicates, and field matrix spikes. This report describes the design for collection of these quality-control samples and the data management needed to properly identify these samples in the U.S. Geological Survey’s national database.

  5. Global review of health care surveys using lot quality assurance sampling (LQAS), 1984-2004.

    Robertson, Susan E; Valadez, Joseph J

    2006-09-01

    We conducted a global review on the use of lot quality assurance sampling (LQAS) to assess health care services, health behaviors, and disease burden. Publications and reports on LQAS surveys were sought from Medline and five other electronic databases; the World Health Organization; the World Bank; governments, nongovernmental organizations, and individual scientists. We identified a total of 805 LQAS surveys conducted by different management groups during January 1984 through December 2004. There was a striking increase in the annual number of LQAS surveys conducted in 2000-2004 (128/year) compared with 1984-1999 (10/year). Surveys were conducted in 55 countries, and in 12 of these countries there were 10 or more LQAS surveys. Geographically, 317 surveys (39.4%) were conducted in Africa, 197 (28.5%) in the Americas, 115 (14.3%) in the Eastern Mediterranean, 114 (14.2%) in South-East Asia, 48 (6.0%) in Europe, and 14 (1.8%) in the Western Pacific. Health care parameters varied, and some surveys assessed more than one parameter. There were 320 surveys about risk factors for HIV/AIDS/sexually transmitted infections; 266 surveys on immunization coverage, 240 surveys post-disasters, 224 surveys on women's health, 142 surveys on growth and nutrition, 136 surveys on diarrheal disease control, and 88 surveys on quality management. LQAS surveys to assess disease burden included 23 neonatal tetanus mortality surveys and 12 surveys on other diseases. LQAS is a practical field method which increasingly is being applied in assessment of preventive and curative health services, and may offer new research opportunities to social scientists. When LQAS data are collected recurrently at multiple time points, they can be used to measure the spatial variation in behavior change. Such data provide insight into understanding relationships between various investments in social, human, and physical capital, and into the effectiveness of different public health strategies in achieving

  6. Control of Bank Consolidated Financial Statements Quality

    Margarita S. Ambarchyan

    2013-01-01

    The author presents the multiple linear regression model of bank consolidated financial statements quality. The article considers six characteristics that can be used to estimate the level of bank consolidated financial statements quality. The multiple linear regression model was developed, using the results of point-based system of consolidated financial statements of thirty European bank and financial groups on the basis of the developed characteristics. The author offers to use the charact...

  7. Study of global control of VIRGO Central Interferometer

    Matone, Luca

    1999-01-01

    The VIRGO project for the detection of gravitational waves will first operate in a test configuration, known as the Central Area Interferometer (CITF). The subject of this thesis consists of a study for the global control of this interferometer. In particular, the problems of auto-alignment and acquisition of lock are addressed. First, an investigation of the CITF optical response to longitudinal and angular mirror movements is given. On the basis of this study, we show how the ratio of photodiode signals can be used to detect and control the dark fringe when the CITF is far from its operating point (locked state). Furthermore, we present the simulation results of a quadrant photodiode configuration capable of reconstructing the mirrors' tilts once the CITF is in a locked state. The performance of a control system for the auto-alignment is then given. A study on the mode-cleaner prototype MC30 is then introduced in order to comprehend the process of lock acquisition by a linear feedback system for two different finesse values: F ≅100 and F ≅ 1600. We define a threshold velocity for the mirrors' relative motion below which acquisition of lock is possible. A phenomenon, referred to as ringing effect, was observed and examined on the MC30 prototype in high finesse. The results of numerical calculations allowed us to fit measurement and estimate from them the cavity finesse as well as the mirrors' relative velocity during the resonance crossing. An empirical formula is then presented capable of determine the relative velocity from the positions of the oscillations' minima and maxima. An algorithm to guide into lock the CITF is then presented, consisting of an iterative procedure of velocity reconstruction and pulse application. A numerical calculation simulated the algorithm, the mirrors' motion, the optical response and the ADCs' process. As a result, acquisition times of the order of one second were observed: an improvement of more than one order of magnitude was

  8. Quality control of recycled asphaltic concrete : final report.

    1982-07-01

    This study examined the variations found in recycled asphaltic concrete mix based upon plant quality control data and verification testing. The data was collected from four recycled hot-mix projects constructed in 1981. All plant control and acceptan...

  9. Quality control of sputum microscopic examinations for acid fast ...

    Preferred Customer

    in the Southern Region of Ethiopia, and quality control has been initiated as part of this effort. Objective: To evaluate the ... National Tuberculosis and Leprosy Control Programme. (TLCP) manual for ..... laboratories in Mexico. Int J Tuberc Lung ...

  10. METHODS OF AUTOMATIC QUALITY CONTROL OF AGGLUTINANTSANDS IN FOUNDRY

    D. M. Kukuj

    2004-01-01

    Full Text Available The article is dedicated to comparative analysis of the well-known methods of automatic quality control of agglutinant sands in process of their preparation and to the problems of automation control of the mix preparation processes.

  11. Managing Air Quality - Multi-Pollutant Planning and Control

    Describes how planning controls for multiple pollutants at the same time can save money and time and achieve significant benefits, and how control strategies can address both climate change and air quality.

  12. Globalization

    Tulio Rosembuj

    2006-12-01

    Full Text Available There is no singular globalization, nor is the result of an individual agent. We could start by saying that global action has different angles and subjects who perform it are different, as well as its objectives. The global is an invisible invasion of materials and immediate effects.

  13. Globalization

    Tulio Rosembuj

    2006-01-01

    There is no singular globalization, nor is the result of an individual agent. We could start by saying that global action has different angles and subjects who perform it are different, as well as its objectives. The global is an invisible invasion of materials and immediate effects.

  14. AUTOMATION OF THE SYSTEM OF INTERNAL LABORATORY QUALITY CONTROL

    V. Z. Stetsyuk

    2015-05-01

    Full Text Available Quality control system base d on the principles of standardi zation of all phases of laboratory testing and analysis of internal laboratory quality control and external quality assessment. For the detection accuracy of the results of laboratory tests, carried out internally between the laboratory and laboratory quality control. Under internal laboratory quality control we understand measurement results of each analysis in each anal ytical series rendered directly in the lab every day. The purpose of internal laboratory control - identifying and eliminating unacceptable deviations from standard perfor mance test in the laboratory, i.e. identifying and eliminating harmful analytical errors. The solutions to these problems by implementing automated systems - software that allows you to optimize analytical laboratory research stage of the procedure by automatically creating process control charts was shown.

  15. Food and Nutrition Services Quality Control Management Program.

    Wimsatt-Fraim, Teresa S.

    A program was conducted to improve the quality of food service through the training of 44 food and nutrition service employees in a 200-bed hospital. A 12-week quality control program was implemented to address four key areas: food temperatures, food accuracy, food quality, and dietary personnel. Learning strategies, emphasizing critical thinking…

  16. The process of managerial control in quality improvement initiatives.

    Slovensky, D J; Fottler, M D

    1994-11-01

    The fundamental intent of strategic management is to position an organization with in its market to exploit organizational competencies and strengths to gain competitive advantage. Competitive advantage may be achieved through such strategies as low cost, high quality, or unique services or products. For health care organizations accredited by the Joint Commission on Accreditation of Healthcare Organizations, continually improving both processes and outcomes of organizational performance--quality improvement--in all operational areas of the organization is a mandated strategy. Defining and measuring quality and controlling the quality improvement strategy remain problematic. The article discusses the nature and processes of managerial control, some potential measures of quality, and related information needs.

  17. Quality control of mammography departments in Slovakia

    Horvathova, M.; Nikodemova, D.

    2007-01-01

    Complete test of publication follows. Considering the fact that mammary gland is the most sensitive organ to ionizing radiation, the Commission of the Ministry of Health of SR for QA in radiology organized a pilot two-run country wide audit conducted in 42 mammography departments that have met the beforehand criteria. During the audit the methods for establishing the individual parameters in technical and clinical part of quality assurance in mammography were elaborated and implemented. Technical and clinical parameters of the imaging process that mostly affect the quality of diagnostic information were followed up. These parameters included: the object thickness compensation, optical density deviation, evaluation of the film quality by means of special phantom, etc. Important measurement of ESDs at participating departments enabled to compare the radiation load of mammography patients in Slovakia with reference values in European guidelines. The uniform standard method for QA at mammography departments was elaborated and published as the regulation of the Ministry of Health for performance of preventive mammography examinations in SR. The presented results show the improved quality of mammography examinations due to regular check-ups of technical and clinical parameters and fulfilment of the required values in all parameters. The audit results are the basis for continuous quality assessment of mammography departments as a main prerequisite for conducting preventive examinations and for health insurance purposes.

  18. [On-site quality control of acupuncture randomized controlled trial: design of content and checklist of quality control based on PICOST].

    Li, Hong-Jiao; He, Li-Yun; Liu, Zhi-Shun; Sun, Ya-Nan; Yan, Shi-Yan; Liu, Jia; Zhao, Ye; Liu, Bao-Yan

    2014-02-01

    To effectively guarantee quality of randomized controlld trial (RCT) of acupuncture and develop reasonable content and checklist of on-site quality control, influencing factors on quality of acupuncture RCT are analyzed and scientificity of quality control content and feasibility of on-site manipulation are put into overall consideration. Based on content and checklist of on-site quality control in National 11th Five-Year Plan Project Optimization of Comprehensive Treatment Plan for TCM in Prevention and Treatment of Serious Disease and Clinical Assessment on Generic Technology and Quality Control Research, it is proposed that on-site quality control of acupuncture RCT should be conducted with PICOST (patient, intervention, comparison, out come, site and time) as core, especially on quality control of interveners' skills and outcome assessment of blinding, and checklist of on-site quality control is developed to provide references for undertaking groups of the project.

  19. Quality control protocols for radiodiagnosis agents and radiopharmaceuticals

    Robles, A.; Condor, M.; Caballero, J.; Morote, M.; Garcia, C.; Benites, M.

    1997-01-01

    Based on the compilation of pharmacopoeia methods, literature, manuals and other information developed in our laboratory, protocols have been prepared to carry out quality controls for radiodiagnosis agents (RDA), better known as kits and RDA labelled with Tc99m. Quality control protocols cover physicochemical and biological controls. Physicochemical controls described for RDA include physical characteristics, particle size and number, pH, chemical identification, humidity, tin II; whereas biological controls include sterility, acute toxicity and bacterial endotoxin determination (LAL). Physicochemical controls described for radiopharmaceuticals labelled with Tc99m are pH and radiochemical purity; while biological distribution is described as a biological control

  20. Intergrated approach to quality control procedures of radioisotopes and radiopharmaceuticals

    Rohani Mohamad

    1986-01-01

    Various aspects of the quality control procedures for radioisotopes and radiopharmaceuticals have been discussed. The paper high lighted those procedures that are important in ensuring the efficacy of the product. It also gives a general idea of the various procedures that are actually carried out by the Quality Control Section. (A.J.)

  1. Electronic quality control on dental x-rays equipment

    Pomares C, Martin

    1996-09-01

    A brief description of dental x-ray equipment is done. The non-invasive quality control is treated as than the responsibilities from the dentists to the patient and the equipment. A propose for quality control for dental x-ray equipment, film and developer is include

  2. Status and future trends of Analytical Quality Control Services

    LaBrecque, J.J.; Schelenz, R.; Hardy, E.P.

    1987-07-01

    This report reviews the present Analytical Quality Control Services (AQCS) programme components in the light of the needs of IAEA Member States for analytical reference materials and intercomparisons, provides guidelines for the direction which the programme should take in the future and identifies the type of Analytical Quality Control Services most urgently required by the Member States

  3. Safety of timber : An analysis of quality control options

    Kovryga, A.; Stapel, P.; Van de Kuilen, J.W.G.

    2014-01-01

    The quality assurance of timber properties is important for the safety of timber structures. In the current study, the quality control options of timber are analysed under the prism of the different growth regions. Therefore, these options - machine and output control - are simulated in accordance

  4. Chemical and physical quality control of the HIPPURAN-131I

    Morin Zorilla, J.; Olive, E.; Isaac, M.; Cruz, J.

    1989-01-01

    Some physico-chemical methods for analytical control of Hippuran- 131 I are compared. The most convenient to applicate in hospitals and in more specialized quality control laboratories are recommended. The quality of Hippuran- 131 I produced by ISOTOP (USSR) is also evaluated. The product met the requirement of the International Pharmacopeia

  5. Internal quality control in serological tests for syphilis.

    Wasley, G D

    1985-01-01

    The importance of syphilis serological tests demands that laboratory reports are reliable. Internal quality control applied to the organisation of a syphilis serology service improves laboratory bench performance and reporting. Described here are internal quality control procedures of a department that serves a genitourinary medicine clinic and conducts 70 000 tests a year to investigate for syphilis.

  6. Application of improved quality control technology to pressure vessels

    Kriedt, F.

    1985-01-01

    Within the last decade, ASME Boiler and Pressure Vessel Code Section VIII-1 instituted requirements for a formal written quality control system. The results, good and bad, of this requirement are discussed. The effects are far reaching from a national economic standpoint. Quality control technology has improved. These improvements are discussed and compared to existing requirements of the CODE. Recommended improvements are suggested

  7. Quality control of geological voxel models using experts' gaze

    Maanen, P.P. van; Busschers, F.S.; Brouwer, A.M.; Meulen, M.J. van der; Erp, J.B.F. van

    2015-01-01

    Due to an expected increase in geological voxel model data-flow and user demands, the development of improved quality control for such models is crucial. This study explores the potential of a new type of quality control that improves the detection of errors by just using gaze behavior of 12

  8. Quality Control of Geological Voxel Models using Experts' Gaze

    van Maanen, Peter-Paul; Busschers, Freek S.; Brouwer, Anne-Marie; van der Meulendijk, Michiel J.; van Erp, Johannes Bernardus Fransiscus

    Due to an expected increase in geological voxel model data-flow and user demands, the development of improved quality control for such models is crucial. This study explores the potential of a new type of quality control that improves the detection of errors by just using gaze behavior of 12

  9. Quality control of nuclear fuels - technical and economic aspects

    Strasser, A.A.

    1982-01-01

    The qualification and resolution of questions relating to the cost benefit of quality control are based on the interaction of a broad range of technologies and economics. This paper discusses examples of current areas of interest in quality control, and their relationship to the fuel cycle costs. (orig.)

  10. Design an Indoor Air Quality Controller Based on LPC2478

    Shi Shuheng

    2014-07-01

    Full Text Available Indoor air quality is very important to our lives, because we spend most of our time indoor. In order to improve the air quality of indoor, this paper designs an indoor environment quality monitoring and controlling system based on ARM microcontroller LPC2478. It will do a real-time monitoring work for detecting the indoor environmental factors and comprehensively evaluate its air quality level. While the indoor air quality status is "poor", this intelligent system will automatically start the heat exchange ventilator for indoor environmental quality improvement. The results compared to traditional natural ventilation method show the better performance of proposed system.

  11. Ensuring on-time quality data management deliverables from global clinical data management teams

    Zia Haque

    2010-01-01

    Full Text Available The growing emphasis on off-site and off-shore clinical data management activities mandates a paramount need for adequate solutions geared toward on-time, quality deliverables. The author has been leading large teams that have been involved in successful global clinical data management endeavors. While each study scenario is unique and has to be approached as such, there are several elements in defining strategy and team structure in global clinical data management that can be applied universally. In this article, key roles, practices, and high-level procedures are laid out as a road map to ensure success with the model.

  12. QUALITY-RELATED FUNDING IN ROMANIAN HIGHER EDUCATION THROUGHOUT 2003 – 2011: A GLOBAL ASSESSMENT

    Gabriel-Alexandru Vîiu

    2015-12-01

    Full Text Available The article explores quality-related funding and its global outcomes in the context of Romanian higher education by focusing on the funding allocations provided to public universities throughout a period of nine years based on their institutional performance on the quality indicators integrated in the funding algorithm. Global funding allocations between universities are analysed and a summative appraisal for the entire nine-year window is provided. The article also explores the relation between quality- related funding, institutional disciplinary profiles and the results of a comprehensive evaluation conducted in 2011 by the Ministry of Education to complete a classification of the universities. The main findings indicate a low overall impact of qualityrelated funding for many institutions, but also a clear pattern in which universities focused on science, technology, engineering and mathematics overwhelmingly outperformed mixed institutions, as well as those focused on humanities, arts and social sciences. Furthermore, the global quality-related funding outcomes of the 2003 – 2011 period studied in the paper are shown to be significantly associated with the results of the 2011 classification

  13. 78 FR 10181 - Global Quality Systems-An Integrated Approach To Improving Medical Product Safety; Public Workshop

    2013-02-13

    ...] Global Quality Systems--An Integrated Approach To Improving Medical Product Safety; Public Workshop... (AFDO), is announcing a public workshop entitled ``Global Quality Systems--An Integrated Approach to... topics concerning FDA requirements related to the production and marketing of drugs and/or devices...

  14. A multi-model assessment of the co-benefits of climate mitigation for global air quality

    Rao, Shilpa; Klimont, Zbigniew; Leitao, Joana; Riahi, Keywan; van Dingenen, Rita; Aleluia Reis, Lara; Calvin, Katherine; Dentener, Frank; Drouet, Laurent; Fujimori, Shinichiro; Harmsen, Mathijs; Luderer, Gunnar; Heyes, Chris; Strefler, Jessica; Tavoni, Massimo; van Vuuren, Detlef P.

    2016-01-01

    We present a model comparison study that combines multiple integrated assessment models with a reduced-form global air quality model to assess the potential co-benefits of global climate mitigation policies in relation to the World Health Organization (WHO) goals on air quality and health. We

  15. Evaluation of global water quality - the potential of a data- and model-driven analysis

    Bärlund, Ilona; Flörke, Martina; Alcamo, Joseph; Völker, Jeanette; Malsy, Marcus; Kaus, Andrew; Reder, Klara; Büttner, Olaf; Katterfeld, Christiane; Dietrich, Désirée; Borchardt, Dietrich

    2016-04-01

    The ongoing socio-economic development presents a new challenge for water quality worldwide, especially in developing and emerging countries. It is estimated that due to population growth and the extension of water supply networks, the amount of waste water will rise sharply. This can lead to an increased risk of surface water quality degradation, if the wastewater is not sufficiently treated. This development has impacts on ecosystems and human health, as well as food security. The United Nations Member States have adopted targets for sustainable development. They include, inter alia, sustainable protection of water quality and sustainable use of water resources. To achieve these goals, appropriate monitoring strategies and the development of indicators for water quality are required. Within the pre-study for a 'World Water Quality Assessment' (WWQA) led by United Nations Environment Programme (UNEP), a methodology for assessing water quality, taking into account the above-mentioned objectives has been developed. The novelty of this methodology is the linked model- and data-driven approach. The focus is on parameters reflecting the key water quality issues, such as increased waste water pollution, salinization or eutrophication. The results from the pre-study show, for example, that already about one seventh of all watercourses in Latin America, Africa and Asia show high organic pollution. This is of central importance for inland fisheries and associated food security. In addition, it could be demonstrated that global water quality databases have large gaps. These must be closed in the future in order to obtain an overall picture of global water quality and to target measures more efficiently. The aim of this presentation is to introduce the methodology developed within the WWQA pre-study and to show selected examples of application in Latin America, Africa and Asia.

  16. Dose calibrator user and quality control guide

    Blanchis, Philippe; Amiot, Marie-Noelle; Moune, Muriel; Bellanger, Anne-Christine; Chauvenet, Bruno; Verdeau, Eric; Gardin, Isabelle; Martineau, Antoine; Ricard, Marcel; Caselles, Olivier; Guilhem, Marie-Therese; Hapdey, Sebastien; Lisbona, Albert; Bonnot-Lours, Sophie; Dumont, Agnes; Lemercier, Valerie; Rizzo-Padoin, Nathalie

    2006-06-01

    This document is a practical guide for the use and control of dose calibrators which are instruments used for radioactivity measurements. After a recall of the calibrator operation principle, the authors describe all the operations performed on this apparatus all along its lifetime: controls to be performed for device acceptance, aspects to be addressed during installation, controls to be performed before any use, daily controls, more detailed controls, and operations to be performed for maintenance, in case of dysfunctions or for re-calibration

  17. Global Accelerator Network, Control Systems And Beam Diagnostics

    Raich, U

    2003-01-01

    Falling funds force all accelerator centers to look for new sources of financing and for the most efficient way of implementing new projects. This very often leads to collaborations between institutes scattered around the globe, a problem well known to big high energy physics experiments. The collaborations working on big detectors e.g. for LHC started thinking about detector acquisition and control systems which can be remotely used from their respective home institutes with minimal support on the spot. This idea was taken up by A. Wagner from DESY for the TESLA machine, who proposed the “Global Accelerator Network” (GAN) enabling users from around the world to run an accelerator remotely. Questions around this subject that immediately come to mind Is the GAN only relevant to big labs ? Or is it reasonable e.g. for operators or engineers in charge to do certain manipulations from home? Are our instruments ready for the GAN? Does the fact of being “GAN ready” increa...

  18. Study of global control of VIRGO Central Interferometer; Etude du controle global de l'Interferometre Central de VIRGO

    Matone, Luca [Paris-11 Univ., 91 Orsay (France)

    1999-10-29

    The VIRGO project for the detection of gravitational waves will first operate in a test configuration, known as the Central Area Interferometer (CITF). The subject of this thesis consists of a study for the global control of this interferometer. In particular, the problems of auto-alignment and acquisition of lock are addressed. First, an investigation of the CITF optical response to longitudinal and angular mirror movements is given. On the basis of this study, we show how the ratio of photodiode signals can be used to detect and control the dark fringe when the CITF is far from its operating point (locked state). Furthermore, we present the simulation results of a quadrant photodiode configuration capable of reconstructing the mirrors' tilts once the CITF is in a locked state. The performance of a control system for the auto-alignment is then given. A study on the mode-cleaner prototype MC30 is then introduced in order to comprehend the process of lock acquisition by a linear feedback system for two different finesse values: F {approx_equal}100 and F {approx_equal} 1600. We define a threshold velocity for the mirrors' relative motion below which acquisition of lock is possible. A phenomenon, referred to as ringing effect, was observed and examined on the MC30 prototype in high finesse. The results of numerical calculations allowed us to fit measurement and estimate from them the cavity finesse as well as the mirrors' relative velocity during the resonance crossing. An empirical formula is then presented capable of determine the relative velocity from the positions of the oscillations' minima and maxima. An algorithm to guide into lock the CITF is then presented, consisting of an iterative procedure of velocity reconstruction and pulse application. A numerical calculation simulated the algorithm, the mirrors' motion, the optical response and the ADCs' process. As a result, acquisition times of the order of one second were observed: an improvement of more than one

  19. Global monitoring of Salmonella serovar distribution from the World Health Organization Global Foodborne Infections Network Country Data Bank: results of quality assured laboratories from 2001 to 2007.

    Hendriksen, Rene S; Vieira, Antonio R; Karlsmose, Susanne; Lo Fo Wong, Danilo M A; Jensen, Arne B; Wegener, Henrik C; Aarestrup, Frank M

    2011-08-01

    Salmonella enterica is commonly acquired from contaminated food and is an important cause of illness worldwide. Interventions are needed to control Salmonella; subtyping Salmonella by serotyping is useful for targeting such interventions. We, therefore, analyzed the global distribution of the 15 most frequently identified serovars of Salmonella isolated from humans from 2001 to 2007 in laboratories from 37 countries that participated in World Health Organization Global Foodborne Infections Network and demonstrated serotyping proficiency in the Global Foodborne Infections Network External Quality Assurance System. In all regions throughout the study period, with the exception of the Oceania and North American regions, Salmonella serovars Enteritidis and Typhimurium ranked as the most common and second most common serovar, respectively. In the North American and Oceania (Australia and New Zealand) regions, Salmonella serovar Typhimurium was the most common serovar reported, and Salmonella serovar Enteritidis was the second most common serovar. During the study period, the proportion of Salmonella isolates reported from humans that were Salmonella serovar Enteritidis was 43.5% (range: 40.6% [2007] to 44.9% [2003]), and Salmonella serovar Typhimurium was 17.1% (range: 15% [2007] to 18.9% [2001]). Salmonella serovars Newport (mainly observed in Latin and North American and European countries), Infantis (dominating in all regions), Virchow (mainly observed in Asian, European, and Oceanic countries), Hadar (profound in European countries), and Agona (intense in Latin and North American and European countries) were also frequently isolated with an overall proportion of 3.5%, 1.8%, 1.5%, 1.5%, and 0.8%, respectively. There were large differences in the most commonly isolated serovars between regions, but lesser differences between countries within the same region. The results also highlight the complexity of the global epidemiology of Salmonella and the need and importance

  20. [Schools, office buildings, leisure settings: diversity of indoor air quality issues. Global review on indoor air quality in these settings].

    Mandin, C; Derbez, M; Kirchner, S

    2012-07-01

    This review provides a global overview of indoor air quality issues in schools, office buildings and recreational settings. It presents the most recent scientific publications and the on-going work conducted in France in the frame of the indoor air quality Observatory. Monitoring campaigns on indoor air quality in schools have been carried out in the recent years in Europe. However, few studies have specifically addressed the role of exposure in these buildings on children's health. Indoor air quality in office buildings has been little studied so far. However, some specificities, such as emissions from electronic devices, frequent cleaning, impossibility to open windows in high-rise buildings, for example, should be examined and their role on the health and comfort studied. Finally, even if the time spent in recreational settings is short, the quality of indoor air should also be considered because of specific pollution. This is the case of indoor swimming pools (exposure to chlorination byproducts) and ice-rinks (exposure to exhaust from machines used to smooth the ice). Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  1. Quality control of thermoluminesce personal dose monitoring

    Shang Aiguo; He Wenchang; Zhao Fengtao

    2006-01-01

    In order to evaluate the influence factor to thermoluminesce personal dose monitoring result, the every question that can appear based on the fact was analyzed. The results show that the detector, annealing, measuring process can influence the monitoring result. It gives some measures to enhance monitoring quality. (authors)

  2. Quality Control Specialist | Center for Cancer Research

    Within the Leidos Biomedical Research Inc.’s Clinical Research Directorate, the Clinical Monitoring Research Program (CMRP) provides high-quality comprehensive and strategic operational support to the high-profile domestic and international clinical research initiatives of the National Cancer Institute (NCI), National Institute of Allergy and Infectious Diseases (NIAID),

  3. Quality assurance in education: The role of ICT and quality control ...

    Quality assurance in education is perceived in this paper to be a product of the impact of information and communication technologies as well as the statutory control measures especially in tertiary institutions in Nigeria. The paper reviews the concept of quality and quality assurance and their general application to ...

  4. How to set up and manage quality control and quality assurance

    Visschedijk, M.; Hendriks, R.; Nuyts, K.

    2005-01-01

    This document provides a general introduction to clarify the differences between quality control (QC) and quality assurance (QA). In addition it serves as a starting point for implementing a quality system approach within an organization. The paper offers practical guidance to the implementation of

  5. Globalization

    Andru?cã Maria Carmen

    2013-01-01

    The field of globalization has highlighted an interdependence implied by a more harmonious understanding determined by the daily interaction between nations through the inducement of peace and the management of streamlining and the effectiveness of the global economy. For the functioning of the globalization, the developing countries that can be helped by the developed ones must be involved. The international community can contribute to the institution of the development environment of the gl...

  6. Proposed quality control protocol of a dual energy bone densitometer from Spanish protocol for quality control of radiology

    Saez, F.; Benito, M. A.; Collado, P.; Saez, M.

    2011-01-01

    In this paper we propose additional testing to complete the tests by the Spanish Protocol for Quality Control of Diagnostic Radiology, taking into account the particular characteristics of these units, and including these tests in the estimation of patient dose dose assessment area. There is also the possibility to independently verify the quality control tests that are done automatically.

  7. The new rules for global trade: certification of origin and quality for safety food

    Geni Satiko Sato

    2009-03-01

    Full Text Available The objective of this article was to describe and to analyze the new context of the global markets for foods, with focus in the certifications of origin and quality, used mechanisms to guarantee the safe, differentiated, traceable food and without frauds. The methodology is characterized as exploratory and descriptive and searched to deepen some excellent concepts on the economy of the quality to agriculture. The complexity of global market and the technology innovations in agriculture and food processing, make the consumer and origin of production so far. The asymmetries of information on the product had grown and increased the transaction costs and, a form to manage the chain productive was to create mechanisms of identification and reputation of the product.

  8. Impact of global climate change on regional air quality: Introduction to the thematic issue

    Vautard, R.; Hauglustaine, D.

    2007-01-01

    Despite the major international efforts devoted to the understanding and to the future estimate of global climate change and its impact on regional scale processes, the evolution of the atmospheric composition in a changing climate is far to be understood. In particular, the future evolution of the concentration of near-surface pollutants determining air quality at a scale affecting human health and ecosystems is a subject of intense scientific research. This thematic issue reviews the current scientific knowledge of the consequences of global climate change on regional air quality and its related impact on the biosphere and on human mortality. This article provides a presentation of the key issues, summarizes the current knowledge, and introduces the thematic issue. (authors)

  9. Quality Management of CERN Vacuum Controls

    Antoniotti, F; Fortescue-Beck, E; Gama, J; Gomes, P; Le Roux, P; Pereira, H F; Pigny, G

    2014-01-01

    The vacuum controls Section (TE-VSC-ICM) is in charge of the monitoring, maintenance and consolidation of the control systems of all accelerators and detectors in CERN; this represents 6 000 instruments distributed along 128 km of vacuum chambers, often of heterogeneous architectures and of diverse

  10. PROCESS VARIABILITY REDUCTION THROUGH STATISTICAL PROCESS CONTROL FOR QUALITY IMPROVEMENT

    B.P. Mahesh

    2010-09-01

    Full Text Available Quality has become one of the most important customer decision factors in the selection among the competing product and services. Consequently, understanding and improving quality is a key factor leading to business success, growth and an enhanced competitive position. Hence quality improvement program should be an integral part of the overall business strategy. According to TQM, the effective way to improve the Quality of the product or service is to improve the process used to build the product. Hence, TQM focuses on process, rather than results as the results are driven by the processes. Many techniques are available for quality improvement. Statistical Process Control (SPC is one such TQM technique which is widely accepted for analyzing quality problems and improving the performance of the production process. This article illustrates the step by step procedure adopted at a soap manufacturing company to improve the Quality by reducing process variability using Statistical Process Control.

  11. Water quality control device and water quality control method for reactor primary coolant system

    Wada, Yoichi; Ibe, Eishi; Watanabe, Atsushi.

    1995-01-01

    The present invention is suitable for preventing defects due to corrosion of structural materials in a primary coolant system of a BWR type reactor. Namely, a concentration measuring means measures the concentration of oxidative ingredients contained in a reactor water. A reducing electrode is disposed along a reactor water flow channel in the primary coolant system and reduces the oxidative ingredients. A reducing counter electrode is disposed along the reactor water flow channel in the primary coolant system, and electrically connected to the reducing electrode. The reactor structural materials are used as a reference electrode providing a reference potential to the reducing electrode and the reducing counter electrode. A potential control means controls the potential of the reducing electrode relative to the reference potential based on the signals from the concentration measuring means. A stable reference potential in a region where an effective oxygen concentration is stable can be obtained irrespective of the change of operation conditions by using the reactor structural materials disposed to a boiling region in the reactor core as a reference electrode. As a result, the water quality can be controlled at high accuracy. (I.S.)

  12. NIF Projects Controls and Information Systems Software Quality Assurance Plan

    Fishler, B

    2011-03-18

    Quality achievement for the National Ignition Facility (NIF) and the National Ignition Campaign (NIC) is the responsibility of the NIF Projects line organization as described in the NIF and Photon Science Directorate Quality Assurance Plan (NIF QA Plan). This Software Quality Assurance Plan (SQAP) is subordinate to the NIF QA Plan and establishes quality assurance (QA) activities for the software subsystems within Controls and Information Systems (CIS). This SQAP implements an activity level software quality assurance plan for NIF Projects as required by the LLNL Institutional Software Quality Assurance Program (ISQAP). Planned QA activities help achieve, assess, and maintain appropriate quality of software developed and/or acquired for control systems, shot data systems, laser performance modeling systems, business applications, industrial control and safety systems, and information technology systems. The objective of this SQAP is to ensure that appropriate controls are developed and implemented for management planning, work execution, and quality assessment of the CIS organization's software activities. The CIS line organization places special QA emphasis on rigorous configuration control, change management, testing, and issue tracking to help achieve its quality goals.

  13. NIF Projects Controls and Information Systems Software Quality Assurance Plan

    Fishler, B.

    2011-01-01

    Quality achievement for the National Ignition Facility (NIF) and the National Ignition Campaign (NIC) is the responsibility of the NIF Projects line organization as described in the NIF and Photon Science Directorate Quality Assurance Plan (NIF QA Plan). This Software Quality Assurance Plan (SQAP) is subordinate to the NIF QA Plan and establishes quality assurance (QA) activities for the software subsystems within Controls and Information Systems (CIS). This SQAP implements an activity level software quality assurance plan for NIF Projects as required by the LLNL Institutional Software Quality Assurance Program (ISQAP). Planned QA activities help achieve, assess, and maintain appropriate quality of software developed and/or acquired for control systems, shot data systems, laser performance modeling systems, business applications, industrial control and safety systems, and information technology systems. The objective of this SQAP is to ensure that appropriate controls are developed and implemented for management planning, work execution, and quality assessment of the CIS organization's software activities. The CIS line organization places special QA emphasis on rigorous configuration control, change management, testing, and issue tracking to help achieve its quality goals.

  14. A phantom for quality control in mammography

    Gambaccini, M.; Rimondi, O.; Marziani, M.; Toti, A.

    1989-01-01

    A phantom for evaluating image quality in mammography has been designed and will be used in the Italian national programme ''Dose and Quality in Mammography''. The characteristics of the phantom are (a) about the same X-ray transmission as a 5 cm 50% fat and 50% water breast for energies between 15 and 50 keV and (b) optimum energies for imaging of the test objects (included in the phantom) in very close agreement with the optimum energies for imaging of calcifications and tumours in a 5 cm 50% fat and 50% water breast. An experimental comparison between the prototype and some commercial phantoms was carried out. Measurements are in progress to test the phantom's ability to evaluate the performances of mammographic systems quantitatively. (author)

  15. Justification and quality control in radiodiagnostics

    Dalen, A. van

    1989-01-01

    The role of the radiodiagnostician in justification of x-ray examination is discussed. Under the final responsibility of the radio-diagnostician the more common examinations are performed by laboratory assistants. A justification judgement before by the radio-diagnostician does not take place. In case of complicated examinations often previous consultation between radio-diagnostician and clinician is necessary. The fast development of new techniques like CT, echography and MRI has as result that the modern radio-diagnostician develops more and more into a imaging-specialist. In the consultation with the clinician he advises about the optimal diagnostics for a certain patient, taking optimally into account the risks of x-radiation. The justifying role of the radio-diagnostician depends further upon the relation with the requiring physician. In general the inter-collegial consultation is assumed to be sufficient within the hospitals, however the feedback to general practitioners seems to be improvable in some cases. With regard to quality assurance it is remarked that the quality of the examination may not be endangered by a too strong emphasis upon radiation reduction. Aspects like education level, protocol learning, dose limits, degressive tariffs, information-transfer, radiation passport, analysis between 'blue' ton, centralization of x-ray examination and quality of apparatus, are discussed. From the Government primarily a constraint setting policy is expected, in which rule-giving with respect to quality of education and apparatus is highly important. A stimulation of inter-collegial consulting may be expected, in particular in financial sense. A permission policy has to be managed, which ensures centralization of apparatus and centrally performance of x-ray examination as much as possible. Finally warning is given for the effects of excessive fear for radiation which causes refraining of medical necessary examination. The various risk have to be weighed up

  16. Some observations about quality control tests of Spect

    Robilotta, C.C.; Rebelo, M.F.S.; Oliveira, M.A.

    1987-01-01

    Some observations about quality control tests done in the tomographic system of Heart Institute are described. Among the tests, the traditional test of quality control with scintillation camera and the specific test for tomography systems are induced. The traditional tests are essential, but not sufficient for evaluating the Spect equipment and the specific tests have been effectuated in controlled conditions. (C.G.C.) [pt

  17. Managing Food Quality Risk in Global Supply Chain: A Risk Management Framework

    Arevalo Chavez, Pablo Jose; Seow, Christopher

    2012-01-01

    Today, the food sector is one of the sectors most vulnerable to intentional contamination by debilitating agents [1]. Some cases of contaminated food have indicated that product quality risk is one of the vulnerabilities in the global supply chain. A series of company scandals, affecting reputation and causing the recall of products and increasing costs have hit the food industry. The obvious problem is that even a minor incident in one part of the chain can have disastrous effects on other p...

  18. Effect of quality control implementation on image quality of radiographic films and irradiation doses to patients

    Cheng Yuxi; Zhou Qipu; Ge Lijuan; Hou Changsong; Qi Xuesong; Yue Baorong; Wang Zuoling; Wei Kedao

    1999-01-01

    Objective: To study the changes in the image quality of radiographic films and the irradiation doses to patients after quality control (QC) implementation. Methods: The entrance surface doses (ESD) to patients measured with TLD and the image quality of radiographic films were evaluated on the basis of CEC image quality criteria. Results: The ESD to patients were significantly reduced after QC implementation (P 0.05), but the post-QC image quality was significantly improved in chest PA, lumbar spine AP and pelvis AP(P0.01 or P<0.05). Conclusion: Significantly reduced irradiation dose with improved image quality can be obtained by QC implementation

  19. Real-time statistical quality control and ARM

    Blough, D.K.

    1992-05-01

    An important component of the Atmospheric Radiation Measurement (ARM) Program is real-time quality control of data obtained from meteorological instruments. It is the goal of the ARM program to enhance the predictive capabilities of global circulation models by incorporating in them more detailed information on the radiative characteristics of the earth's atmosphere. To this end, a number of Cloud and Radiation Testbeds (CART's) will be built at various locations worldwide. Each CART will consist of an array of instruments designed to collect radiative data. The large amount of data obtained from these instruments necessitates real-time processing in order to flag outliers and possible instrument malfunction. The Bayesian dynamic linear model (DLM) proves to be an effective way of monitoring the time series data which each instrument generates. It provides a flexible yet powerful approach to detecting in real-time sudden shifts in a non-stationary multivariate time series. An application of these techniques to data arising from a remote sensing instrument to be used in the CART is provided. Using real data from a wind profiler, the ability of the DLM to detect outliers is studied. 5 refs

  20. Management Model for efficient quality control in new buildings

    C. E. Rodríguez-Jiménez

    2017-09-01

    Full Text Available The management of the quality control of each building process is usually set up in Spain from different levels of demand. This work tries to obtain a model of reference, to compare the quality control of the building process of a specific product (building, and to be able to evaluate its warranty level. In the quest of this purpose, we take credit of specialized sources and 153 real cases of Quality Control were carefully revised using a multi-judgment method. Applying different techniques to get a specific valuation (impartial of the input parameters through Delphi’s method (17 experts query, whose matrix treatment with the Fuzzy-QFD tool condenses numerical references through a weighted distribution of the selected functions and their corresponding conditioning factors. The model thus obtained (M153 is useful in order to have a quality control reference to meet the expectations of the quality.

  1. [Evaluation of the quality control system in blood transfusion service].

    Jovanović, R

    2000-01-01

    Implementation of quality system improvement at the Blood Transfusion Institute Novi Sad, included adjustments in practice to the request of ISO 9001 standard. Quality improvement must be a permanent activity of the Institute. The audit is a management tool for monitoring the quality assurance system and is either a quality audit or a medical audit. A well planned, comprehensive quality audit covers each activity of the Blood Transfusion Institute. The procedures may be internal or external. Quality manager is responsible for annual internal quality audits. The purpose of internal audits is to check the efficiency of the quality system in terms of realization of quality policy, fulfullment of designed targets and implementation of quality system documents. An internal quality audit is performed in accordance with the procedure and audit findings are reported to the management in a form of internal quality report as a part of quality system review. The findings must be communicated to all persons responsible for the controlled area. Quality manager can initiate an internal quality audit whenever it is realized that problems about the quality system have occurred. Audits are conducted by the quality manager or an audit team. The accurate list of internal auditors is kept in the Institute archive. Medical audit carried out by a transfusion committee, evaluates the quality of blood transfusion for determining the degree of compliance with established local or national guidelines, in order to promote optimal transfusion practice. Audits are not only used for determining further quality management activities, but also make basis for creating and maintenance of excellent relations with product and service users. Considering all this, Blood Transfusion Institute exceeds the requirements of ISO 9000 standards series.

  2. GNAQPMS v1.1: accelerating the Global Nested Air Quality Prediction Modeling System (GNAQPMS) on Intel Xeon Phi processors

    H. Wang; H. Wang; H. Wang; H. Wang; H. Chen; H. Chen; Q. Wu; Q. Wu; J. Lin; X. Chen; X. Xie; R. Wang; R. Wang; X. Tang; Z. Wang

    2017-01-01

    The Global Nested Air Quality Prediction Modeling System (GNAQPMS) is the global version of the Nested Air Quality Prediction Modeling System (NAQPMS), which is a multi-scale chemical transport model used for air quality forecast and atmospheric environmental research. In this study, we present the porting and optimisation of GNAQPMS on a second-generation Intel Xeon Phi processor, codenamed Knights Landing (KNL). Compared with the first-generation Xeon Phi coprocessor (code...

  3. Using a biocultural approach to examine migration/globalization, diet quality, and energy balance.

    Himmelgreen, David A; Cantor, Allison; Arias, Sara; Romero Daza, Nancy

    2014-07-01

    The aim of this paper is to examine the role and impact that globalization and migration (e.g., intra-/intercontinental, urban/rural, and circular) have had on diet patterns, diet quality, and energy balance as reported on in the literature during the last 20 years. Published literature from the fields of anthropology, public health, nutrition, and other disciplines (e.g., economics) was collected and reviewed. In addition, case studies from the authors' own research are presented in order to elaborate on key points and dietary trends identified in the literature. While this review is not intended to be comprehensive, the findings suggest that the effects of migration and globalization on diet quality and energy balance are neither lineal nor direct, and that the role of social and physical environments, culture, social organization, and technology must be taken into account to better understand this relationship. Moreover, concepts such as acculturation and the nutrition transition do not necessarily explain or adequately describe all of the global processes that shape diet quality and energy balance. Theories from nutritional anthropology and critical bio-cultural medical anthropology are used to tease out some of these complex interrelationships. Copyright © 2014. Published by Elsevier Inc.

  4. The global impact of ozone on agricultural crop yields under current and future air quality legislation

    Van Dingenen, Rita; Dentener, Frank J.; Raes, Frank; Krol, Maarten C.; Emberson, Lisa; Cofala, Janusz

    In this paper we evaluate the global impact of surface ozone on four types of agricultural crop. The study is based on modelled global hourly ozone fields for the year 2000 and 2030, using the global 1°×1° 2-way nested atmospheric chemical transport model (TM5). Projections for the year 2030 are based on the relatively optimistic "current legislation (CLE) scenario", i.e. assuming that currently approved air quality legislation will be fully implemented by the year 2030, without a further development of new abatement policies. For both runs, the relative yield loss due to ozone damage is evaluated based on two different indices (accumulated concentration above a 40 ppbV threshold and seasonal mean daytime ozone concentration respectively) on a global, regional and national scale. The cumulative metric appears to be far less robust than the seasonal mean, while the seasonal mean shows satisfactory agreement with measurements in Europe, the US, China and Southern India and South-East Asia. Present day global relative yield losses are estimated to range between 7% and 12% for wheat, between 6% and 16% for soybean, between 3% and 4% for rice, and between 3% and 5% for maize (range resulting from different metrics used). Taking into account possible biases in our assessment, introduced through the global application of "western" crop exposure-response functions, and through model performance in reproducing ozone-exposure metrics, our estimates may be considered as being conservative. Under the 2030 CLE scenario, the global situation is expected to deteriorate mainly for wheat (additional 2-6% loss globally) and rice (additional 1-2% loss globally). India, for which no mitigation measures have been assumed by 2030, accounts for 50% of these global increase in crop yield loss. On a regional-scale, significant reductions in crop losses by CLE-2030 are only predicted in Europe (soybean) and China (wheat). Translating these assumed yield losses into total global economic

  5. Fuel element radiometry system for quality control

    Bhattacharya, Sadhana; Gaur, Swati; Sridhar, Padmini; Mukhopadhyay, P.K.; Vaidya, P.R.; Das, Sanjoy; Sinha, A.K.; Bhatt, Sameer

    2010-01-01

    An indigenous and fully automatic PC based radiometry system has been designed and developed. The system required a vibration free scanning with various automated sequential movements to scan the fuel pin of size 5.8 mm (OD) x 1055 mm (L) along its full length. A mechanical system with these requirements and precision controls has been designed. The system consists of a tightly coupled and collimated radiation source-detector unit and data acquisition and control system. It supports PLC based control electronics to control and monitor the movement of fuel element, nuclear data acquisition and analysis system and feedback system to the mechanical scanner to physically accept or reject the fuel pin based on the decision derived by the software algorithms. (author)

  6. Quality control test solutions for diagnostic radiology, nuclear medicine and health physics with PTW equipment

    Froescher, Olga

    2007-01-01

    Complete test of publication follows. In 1922 PTW-Freiburg was founded to produce and market a revolutionary new electromechanical component for measuring very small electrical charges. Today PTW is the specialist and one of the global market leaders for manufacturing and supplying high-quality products in diagnostic radiology, nuclear medicine, radiation therapy and health physics. The quality control of X-ray images is influenced by a number of parameters. To maintain a consistent performance of X-ray installations, quality checks have to be conducted regularly. PTW offers a variety of diagnostic test tools for different X-ray devices, and therefore to reduce patient exposure and costs for X-ray departments. PTW's 'Code of Practice' defines in an easy and compact way how to perform quality control measurements on different diagnostic X-ray installations. The necessary equipment for measuring main parameters as well as acceptable limits are mentioned accordingly. The 'Code of Practice' bases on actual standards.

  7. Quality control of radioactive waste products

    Martens, B.R.; Warnecke, E.; Odoj, R.

    1986-01-01

    The variety of incoming untreated wastes, treatment methods, waste forms and containers requires a great variety of controlling methods and principles to be applied both during waste treatment and on the final product. The paper describes product control schemes and methods, sampling systems and transportable testing equipment for waste drums, and equipment for waste cementation using in-drum stirring and subsequent fixation of solid wastes in the flowable product. (DG) [de

  8. The endoscopy Global Rating Scale – Canada: Development and implementation of a quality improvement tool

    MacIntosh, Donald; Dubé, Catherine; Hollingworth, Roger; van Zanten, Sander Veldhuyzen; Daniels, Sandra; Ghattas, George

    2013-01-01

    BACKGROUND: Increasing use of gastrointestinal endoscopy, particularly for colorectal cancer screening, and increasing emphasis on health care quality highlight the need for endoscopy facilities to review the quality of the service they offer. OBJECTIVE: To adapt the United Kingdom Global Rating Scale (UK-GRS) to develop a web-based and patient-centred tool to assess and improve the quality of endoscopy services provided. METHODS: Based on feedback from 22 sites across Canada that completed the UK endoscopy GRS, and integrating results of the Canadian consensus on safety and quality indicators in endoscopy and other Canadian consensus reports, a working group of endoscopists experienced with the GRS developed the GRS-Canada (GRS-C). RESULTS: The GRS-C mirrors the two dimensions (clinical quality and quality of the patient experience) and 12 patient-centred items of the UK-GRS, but was modified to apply to Canadian health care infrastructure, language and current practice. Each item is assessed by a yes/no response to eight to 12 statements that are divided into levels graded D (basic) through A (advanced). A core team consisting of a booking clerk, charge nurse and the physician responsible for the unit is recommended to complete the GRS-C twice yearly. CONCLUSION: The GRS-C is intended to improve endoscopic services in Canada by providing endoscopy units with a straightforward process to review the quality of the service they provide. PMID:23472242

  9. The endoscopy Global Rating Scale-Canada: development and implementation of a quality improvement tool.

    MacIntosh, Donald; Dubé, Catherine; Hollingworth, Roger; Veldhuyzen van Zanten, Sander; Daniels, Sandra; Ghattas, George

    2013-02-01

    Increasing use of gastrointestinal endoscopy, particularly for colorectal cancer screening, and increasing emphasis on health care quality highlight the need for endoscopy facilities to review the quality of the service they offer. To adapt the United Kingdom Global Rating Scale (UK-GRS) to develop a web-based and patient-centred tool to assess and improve the quality of endoscopy services provided. Based on feedback from 22 sites across Canada that completed the UK endoscopy GRS, and integrating results of the Canadian consensus on safety and quality indicators in endoscopy and other Canadian consensus reports, a working group of endoscopists experienced with the GRS developed the GRS-Canada (GRS-C). The GRS-C mirrors the two dimensions (clinical quality and quality of the patient experience) and 12 patient-centred items of the UK-GRS, but was modified to apply to Canadian health care infrastructure, language and current practice. Each item is assessed by a yes⁄no response to eight to 12 statements that are divided into levels graded D (basic) through A (advanced). A core team consisting of a booking clerk, charge nurse and the physician responsible for the unit is recommended to complete the GRS-C twice yearly. The GRS-C is intended to improve endoscopic services in Canada by providing endoscopy units with a straightforward process to review the quality of the service they provide.

  10. Global impacts of conversions from natural to agricultural ecosystems on water resources: Quantity versus quality

    Scanlon, Bridget R.; Jolly, Ian; Sophocleous, Marios; Zhang, Lu

    2007-03-01

    Past land use changes have greatly impacted global water resources, with often opposing effects on water quantity and quality. Increases in rain-fed cropland (460%) and pastureland (560%) during the past 300 years from forest and grasslands decreased evapotranspiration and increased recharge (two orders of magnitude) and streamflow (one order of magnitude). However, increased water quantity degraded water quality by mobilization of salts, salinization caused by shallow water tables, and fertilizer leaching into underlying aquifers that discharge to streams. Since the 1950s, irrigated agriculture has expanded globally by 174%, accounting for ˜90% of global freshwater consumption. Irrigation based on surface water reduced streamflow and raised water tables resulting in waterlogging in many areas (China, India, and United States). Marked increases in groundwater-fed irrigation in the last few decades in these areas has lowered water tables (≤1 m/yr) and reduced streamflow. Degradation of water quality in irrigated areas has resulted from processes similar to those in rain-fed agriculture: salt mobilization, salinization in waterlogged areas, and fertilizer leaching. Strategies for remediating water resource problems related to agriculture often have opposing effects on water quantity and quality. Long time lags (decades to centuries) between land use changes and system response (e.g., recharge, streamflow, and water quality), particularly in semiarid regions, mean that the full impact of land use changes has not been realized in many areas and remediation to reverse impacts will also take a long time. Future land use changes should consider potential impacts on water resources, particularly trade-offs between water, salt, and nutrient balances, to develop sustainable water resources to meet human and ecosystem needs.

  11. A multi-model assessment of the co-benefits of climate mitigation for global air quality

    Rao, Shilpa; Klimont, Zbigniew; Leitao, Joana; Riahi, Keywan; van Dingenen, Rita; Reis, Lara Aleluia; Calvin, Katherine; Dentener, Frank; Drouet, Laurent; Fujimori, Shinichiro; Harmsen, Mathijs; Luderer, Gunnar; Heyes, Chris; Strefler, Jessica; Tavoni, Massimo; van Vuuren, Detlef P.

    2016-12-01

    The recent International Panel on Climate change (IPCC) report identifies significant co-benefits from climate policies on near-term ambient air pollution and related human health outcomes [1]. This is increasingly relevant for policy making as the health impacts of air pollution are a major global concern- the Global Burden of Disease (GBD) study identifies outdoor air pollution as the sixth major cause of death globally [2]. Integrated assessment models (IAMs) are an effective tool to evaluate future air pollution outcomes across a wide range of assumptions on socio-economic development and policy regimes. The Representative Concentration Pathways (RCPs) [3] were the first set of long-term global scenarios developed across multiple integrated assessment models that provided detailed estimates of a number of air pollutants until 2100. However these scenarios were primarily designed to cover a defined range of radiative forcing outcomes and thus did not specifically focus on the interactions of long-term climate goals on near-term air pollution impacts. More recently, [4] used the RCP4.5 scenario to evaluate the co-benefits of global GHG reductions on air quality and human health in 2030. [5-7] have further examined the interactions of more diverse pollution control regimes with climate policies. This paper extends the listed studies in a number of ways. Firstly it uses multiple IAMs to look into the co-benefits of a global climate policy for ambient air pollution under harmonized assumptions on near-term air pollution control. Multi-model frameworks have been extensively used in the analysis of climate change mitigation pathways, and the structural uncertainties regarding the underlying mechanisms (see for example [8-10]. This is to our knowledge the first time that a multi-model evaluation has been specifically designed and applied to analyze the co-benefits of climate change policy on ambient air quality, thus enabling a better understanding of at a detailed

  12. Dosimetry and quality control in radiodiagnosis

    Le Gouic, M.

    1983-07-01

    This work deals with physics of radiodiagnosis. In a first part a study of the characteristics of different kinds of radiological equipments and a quality assurance of some of them (standard radiography, coronarography and computed tomography) have been performed. The second part deals with patient irradiation. After a bibliographic study of radiodiagnosis dosimetry, two kinds of dosimetric measures have been made: ''in vitro'' measures, using a phantom, that had allowed to calibrate the equipment and to improve the individual irradiation card, and ''in vivo'' measures. For the first types of measures ionization chambers, have been used for the second thermoluminescent dosimeters [fr

  13. Internal control reporting and accounting quality : Insight "comply-or-explain" internal control regime

    Cao Thi Thanh, Huyen; Cheung, Tina

    2010-01-01

    Nowadays, there exist two reporting regimes, rules-based and principle-based (comply-or-explain). In the rules-based environment, researchers have studied the relationship between internal control quality and accounting quality. Prior studies have suggested that reports on internal control are an effective way for investors to evaluate the quality of the firm‟s internal control. By having a sound system of internal control, it creates reliance upon the firm‟s financial reporting. Therefore, t...

  14. Internal quality control of PCR-based genotyping methods

    Bladbjerg, Else-Marie; Gram, Jørgen; Jespersen, Jørgen

    2002-01-01

    Internal quality control programmes for genetic analyses are needed. We have focused on quality control aspects of selected polymorphism analyses used in thrombosis research. DNA was isolated from EDTA-blood (n = 500) and analysed for 18 polymorphisms by polymerase chain reaction (PCR), i...... because of positive reagent blanks (controls (Control of data handling revealed 0.1% reading mistakes and 0.5% entry mistakes. Based on our experiences, we propose an internal quality control programme......, electrophoresis (analytical factors), result reading and entry into a database (post-analytical factors). Furthermore, we evaluated a procedure for result confirmation. Isolated DNA was of good quality (42 micrograms/ml blood, A260/A280 ratio > 1.75, negative DNAsis tests). Occasionally, results were reanalysed...

  15. Error control coding schemes in digital systems | Kwaha | Global ...

    Global Journal of Pure and Applied Sciences. Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives · Journal Home > Vol 8, No 3 (2002) >. Log in or Register to get access to full text downloads.

  16. The Internet: a global free space with limited state control

    Dommering, E.; van Ginkel, B.; de Goede, M.; Koops, B.J.; Plooij-van Gorsel, E.; Verrijn Stuart, H.; Smallenbroek, J.

    2015-01-01

    Chapter II explains that the internet, as represented by the internet community, has broken free of the traditional structure of the telecommunication sector under international law, namely a convention (recording global agreements about telecommunications) and an international organisation (the

  17. Global controls on carbon storage in mangrove soils

    Rovai, André S.; Twilley, Robert R.; Castañeda-Moya, Edward; Riul, Pablo; Cifuentes-Jara, Miguel; Manrow-Villalobos, Marilyn; Horta, Paulo A.; Simonassi, José C.; Fonseca, Alessandra L.; Pagliosa, Paulo R.

    2018-06-01

    Global-scale variation in mangrove ecosystem properties has been explained using a conceptual framework linking geomorphological processes to distinct coastal environmental settings (CES) for nearly 50 years. However, these assumptions have not been empirically tested at the global scale. Here, we show that CES account for global variability in mangrove soil C:N:P stoichiometry and soil organic carbon (SOC) stocks. Using this ecogeomorphology framework, we developed a global model that captures variation in mangrove SOC stocks compatible with distinct CES. We show that mangrove SOC stocks have been underestimated by up to 50% (a difference of roughly 200 Mg ha-1) in carbonate settings and overestimated by up to 86% (around 400 Mg ha-1) in deltaic coastlines. Moreover, we provide information for 57 nations that currently lack SOC data, enabling these and other countries to develop or evaluate their blue carbon inventories.

  18. Quality control of CANDU6 fuel element in fabrication process

    Li Yinxie; Zhang Jie

    2012-01-01

    To enhance the fine control over all aspects of the production process, improve product quality, fuel element fabrication process for CANDU6 quality process control activities carried out by professional technical and management technology combined mode, the quality of the fuel elements formed around CANDU6 weak links - - end plug , and brazing processes and procedures associated with this aspect of strict control, in improving staff quality consciousness, strengthening equipment maintenance, improved tooling, fixtures, optimization process test, strengthen supervision, fine inspection operations, timely delivery carry out aspects of the quality of information and concerns the production environment, etc., to find the problem from the improvement of product quality and factors affecting the source, and resolved to form the active control, comprehensive and systematic analysis of the problem of the quality management concepts, effectively reducing the end plug weld microstructure after the failure times and number of defects zirconium alloys brazed, improved product quality, and created economic benefits expressly provided, while staff quality consciousness and attention to detail, collaboration department, communication has been greatly improved and achieved very good management effectiveness. (authors)

  19. APPLICATION OF HIDDEN MARKOV CHAINS IN QUALITY CONTROL

    Hanife DEMIRALP

    2013-01-01

    Full Text Available The ever growing technological innovations and sophistication in industrial processes require adequate checks on quality. Thus, there is an increasing demand for simple and efficient quality control methods. In this regard the control charts stand out in simplicity and efficiency. In this paper, we propose a method of controlling quality based on the theory of hidden Markov chains. Based on samples drawn at different times from the production process, the method obtains the state of the process probabilistically. The main advantage of the method is that it requires no assumption on the normality of the process output.

  20. Study of global control of VIRGO Central Interferometer; Etude du controle global de l'Interferometre Central de VIRGO

    Matone, Luca [Paris-11 Univ., 91 Orsay (France)

    1999-10-29

    The VIRGO project for the detection of gravitational waves will first operate in a test configuration, known as the Central Area Interferometer (CITF). The subject of this thesis consists of a study for the global control of this interferometer. In particular, the problems of auto-alignment and acquisition of lock are addressed. First, an investigation of the CITF optical response to longitudinal and angular mirror movements is given. On the basis of this study, we show how the ratio of photodiode signals can be used to detect and control the dark fringe when the CITF is far from its operating point (locked state). Furthermore, we present the simulation results of a quadrant photodiode configuration capable of reconstructing the mirrors' tilts once the CITF is in a locked state. The performance of a control system for the auto-alignment is then given. A study on the mode-cleaner prototype MC30 is then introduced in order to comprehend the process of lock acquisition by a linear feedback system for two different finesse values: F {approx_equal}100 and F {approx_equal} 1600. We define a threshold velocity for the mirrors' relative motion below which acquisition of lock is possible. A phenomenon, referred to as ringing effect, was observed and examined on the MC30 prototype in high finesse. The results of numerical calculations allowed us to fit measurement and estimate from them the cavity finesse as well as the mirrors' relative velocity during the resonance crossing. An empirical formula is then presented capable of determine the relative velocity from the positions of the oscillations' minima and maxima. An algorithm to guide into lock the CITF is then presented, consisting of an iterative procedure of velocity reconstruction and pulse application. A numerical calculation simulated the algorithm, the mirrors' motion, the optical response and the ADCs' process. As a result, acquisition times of the order of one second were observed: an

  1. Measurement of Quality of Life III. From the IQOL Theory to the Global, Generic SEQOL Questionnaire

    Soren Ventegodt

    2003-01-01

    Full Text Available The Danish Quality of Life Survey is based on the philosophy of life known as the integrative quality-of-life (IQOL theory. It consists of eight different quality-of-life concepts, ranging from the superficially subjective via the deeply existential to the superficially objective (well being, satisfaction with life, happiness, meaning in life, biological order, realizing life potential, fulfillment of needs, and objective factors [ability of functioning and fulfilling societal norms].This paper presents the work underlying the formulation of the theories of a good life and how these theories came to be expressed in a comprehensive, multidimensional, generic questionnaire for the evaluation of the global quality of life � SEQOL (self-evaluation of quality of life � presented in full length in this paper. The instruments and theories on which the Quality of Life Survey was based are constantly being updated. It is an on-going process due to aspects such as human development, language, and culture. We arrived at eight rating scales for the quality of life that, guided by the IQOL theory, were combined into a global and generic quality-of-life rating scale. This was simplified to the validated QOL5 with only five questions, made for use in clinical databases. Unfortunately, the depth of human existence is to some extent lost in QOL5.We continue to aim towards greater simplicity, precision, and depth in the questions in order to explore the depths of human existence. We have not yet found a final form that enables us to fully rate the quality of life in practice. We hope that the several hundred questions we found necessary to adequately implement the theories of the Quality of Life Survey can be replaced by far fewer; ideally, only eight questions representing the eight component theories. These eight ideal questions have not yet been evaluated, and therefore they should not form the basis of a survey. However, the perspective is clear. If eight

  2. Results of Use of WHO Global Salm-Surv External Quality Assurance System for Antimicrobial Susceptibility Testing of Salmonella Isolates from 2000 to 2007

    Hendriksen, Rene S.; Seyfarth, Anne Mette; Jensen, Arne Bent

    2009-01-01

    laboratories in 102 countries participated in at least one EQAS iteration. A large number of laboratories reported results for the E. coli ATCC 25922 reference strain which were outside the quality control ranges. Critical deviations for susceptibility testing of the Salmonella isolates varied from 4% in 2000......An international External Quality Assurance System (EQAS) for antimicrobial susceptibility testing of Salmonella was initiated in 2000 by the World Health Organization (WHO) Global Salm-Surv in order to enhance the capacities of national reference laboratories to obtain reliable data....... In particular, further training and dissemination of information on quality control, appropriate interpretive criteria (breakpoints), and harmonization of the methodology worldwide through WHO Global Salm-Surv and other programs will contribute to the generation of comparable and reliable antimicrobial...

  3. Diagnostic Accuracy of Global Pharma Health Fund Minilab™ in Assessing Pharmacopoeial Quality of Antimicrobials.

    Pan, Hui; Ba-Thein, William

    2018-01-01

    Global Pharma Health Fund (GPHF) Minilab™, a semi-quantitative thin-layer chromatography (TLC)-based commercially available test kit, is widely used in drug quality surveillance globally, but its diagnostic accuracy is unclear. We investigated the diagnostic accuracy of Minilab system for antimicrobials, using high-performance liquid chromatography (HPLC) as reference standard. Following the Minilab protocols and the Pharmacopoeia of the People's Republic of China protocols, Minilab-TLC and HPLC were used to test five common antimicrobials (506 batches) for relative concentration of active pharmaceutical ingredients. The prevalence of poor-quality antimicrobials determined, respectively, by Minilab TLC and HPLC was amoxicillin (0% versus 14.9%), azithromycin (0% versus 17.4%), cefuroxime axetil (14.3% versus 0%), levofloxacin (0% versus 3.0%), and metronidazole (0% versus 38.0%). The Minilab TLC had false-positive and false-negative detection rates of 2.6% (13/506) and 15.2% (77/506) accordingly, resulting in the following test characteristics: sensitivity 0%, specificity 97.0%, positive predictive value 0, negative predictive value 0.8, positive likelihood ratio 0, negative likelihood ratio 1.0, diagnostic odds ratio 0, and adjusted diagnostic odds ratio 0.2. This study demonstrates unsatisfying diagnostic accuracy of Minilab system in screening poor-quality antimicrobials of common use. Using Minilab as a stand-alone system for monitoring drug quality should be reconsidered.

  4. Implementation of quality control systematics for personnel monitoring services

    Franco, J.O.A.

    1984-01-01

    The implementation of statistical quality control techniques used in industrial practise is proposed to dosimetric services. 'Control charts' and 'sampling inspection' are adapted respectively for control of measuring process and of dose results produced in routine. A chapter on Radiation Protection and Personnel Monitoring was included. (M.A.C.) [pt

  5. Web quality control for lectures: Supercourse and Amazon.com.

    Linkov, Faina; LaPorte, Ronald; Lovalekar, Mita; Dodani, Sunita

    2005-12-01

    Peer review has been at the corner stone of quality control of the biomedical journals in the past 300 years. With the emergency of the Internet, new models of quality control and peer review are emerging. However, such models are poorly investigated. We would argue that the popular system of quality control used in Amazon.com offers a way to ensure continuous quality improvement in the area of research communications on the Internet. Such system is providing an interesting alternative to the traditional peer review approaches used in the biomedical journals and challenges the traditional paradigms of scientific publishing. This idea is being explored in the context of Supercourse, a library of 2,350 prevention lectures, shared for free by faculty members from over 150 countries. Supercourse is successfully utilizing quality control approaches that are similar to Amazon.com model. Clearly, the existing approaches and emerging alternatives for quality control in scientific communications needs to be assessed scientifically. Rapid explosion of internet technologies could be leveraged to produce better, more cost effective systems for quality control in the biomedical publications and across all sciences.

  6. USE OF INTELLECTUAL TECHNOLOGIES FOR QUALITY CONTROL OF CURD

    M. M. Blagoveshchenskaya

    2015-01-01

    Full Text Available In this article, we consider additional method of quality control of curds by organoleptic properties. Method consists in construction of neural network model to estimate quality of curds by input and output parameters. Quality control of curds by organoleptic properties is not necessary according to state standard specification, therefore we use exemplary 5-score scale for organoleptic estimation. Author gives an example of fundamental operation which is necessary for neural networks projection and gives recommendation for integrated hardware/software solution design. This method makes easier quality control of final product because operator can react on digression in the technological process in proper time (use data recommended by neural network, predict quality of final product in case when technological parameters deviate from the norm.

  7. Cold plasma: Quality control and regulatory considerations

    In recent years, cold plasma has emerged as a promising antimicrobial treatment for fresh and fresh-cut produce, nuts, spices, seeds, and other foods. Research has demonstrated effective control of human pathogens such as Salmonella, Listeria monocytogenes, Escherichia coli O157:H7, norovirus, and o...

  8. Hippuran-123 I: labelling and quality control

    Barboza, M.F. de; Colturato, M.T.; Herrerias, R.; Muramoto, E.

    1992-01-01

    The o-iodo hippuric acid labelling with radioiodine is a radiopharmaceutical used with more frequently for evaluation the kidney function. Several reactive kits for labelling with 123 I are prepared. Controls of radiochemical purity and biological distribution are made. The reactive kit of hippuran is kept at 4 C during 2 years. (C.G.C.)

  9. [The occupational physician as global consultant for implementing the quality systems].

    Apostoli, P; Pugliese, F

    2010-01-01

    From many years the quality systems and the occupational prevention have been compared and connected both on theoretical and practical fields. The opportunity to discuss again and to deepen these themes appears to be mandatory to be able to govern the new working processes which shall follow the worldwide financial and productive crisis of last period and in our country to try to adequately apply the preventive norms 81/08 and 106/09. In this contribution we will deal with quality systems more intertwined with prevention (ISO 14000, EMAS, SA8000 and OHSAS 18001 and discuss in particular the role of with occupational physician in his meaning of global consultant for enterprise, a crucial technical figure in a typical multidisciplinary process as the implementation of the quality systems.

  10. Preparation and quality control of ECD kit

    Yassin, T.; Dadokh, M.; Almalki, R.

    2005-05-01

    ECD Kit for brain imaging after labeling with technetium 99m was prepared according to an optimum conditions, Each vial contains 1 mg of ECD and 0.155 mg of stannous chloride anhydrous SnCl 2 , 24 mg of Mannitol and 0.5 mg of Na 2 Ca EDTA, The prepared kit showed high quality satisfying the requirements of international pharmacopoeias from the points of physical, chemical, radiochemical and biological purities, and its validity for human injection. And the labeling yield exceeded 95 % with average value of about 97.63 ± 0.89% for 2mCi /2ml radioactivity , This study also showed that each vial content can be labeled with maximum activity of 99m Tc of about 50 mCi (Authors)

  11. The CEA contribution to quality control

    Rapin, M.; Colomer, J.

    1979-01-01

    The Commissariat a l'Energie Atomique has developed original methods and techniques for testing delicate components of the primary circuit of pressure water reactors. These techniques make use of a very wide range of non destructive testing methods: Eddy currents, particularly multiple frequencies, for testing steam generator tubes, gudgeon and other pins focused ultrasonics for testing all the welds of the reactor vessel and its cover plate, mixed welds of steam vessels and generators, low welds of the pressurizer and gudgeon pins from the inside. On site use is effected with specific machines intended either for inspecting the tube bundles of steam generators under the responsibility of INTERCONTROLE Co., or for the complete examination of the reactor vessel by mixed CEA/INTERCONTROLE crews under the responsibility of the CEA. All these operations are subjected to a programme of quality assurance that provides the guaranty of execution complying with the procedures in force [fr

  12. Quality control activities in the environmental radiology laboratory

    Llaurado, M.; Quesada, D.; Rauret, G.; Tent, J.; Zapata, D.

    2006-01-01

    During the last twenty years many analytical laboratories have implemented quality assurance systems. A quality system implementation requires documentation of all activities (technical and management), evaluation of these activities and its continual improvement. Implementation and adequate management of all the elements a quality system includes are not enough to guarantee quality of the analytical results generated at a time. That is the aim of a group of specific activities labelled as quality control activities. The Laboratori de Radiologia Ambiental (Environmental Radiology Laboratory; LRA) at the University of Barcelona was created in 1984 to carry out part of the quality control assays of the Environmental Radiology Monitoring Programs around some of the Spanish nuclear power plants, which are developed by the Servei Catala d'Activitats Energetiques (SCAR) and the Consejo de Seguridad Nuclear (CSN), organisations responsible for nuclear security and radiological protection. In these kind of laboratories, given the importance of the results they give, quality control activities become an essential aspect. In order to guarantee the quality of its analytical results, the LRA Direction decided to adopt the international standard UNE-EN ISO/IEC 17025 for its internal quality system and to accreditate some of the assays it carries out. In such as system, it is established, the laboratory shall monitor the validity of tests undertaken and data shall be recorded in such a way that trends are detectable. The present work shows the activities carried out in this way by the LRA, which are: Equipment control activities which in the special case of radiochemical techniques include measurement of backgrounds and blanks as well as periodical control of efficiency and resolution. Activities to assure the specifications settled by method validation, which are testing of reference materials and periodical analysis of control samples. Evaluation of the laboratory work quality

  13. European quality assurance and quality control for cut-off walls and caps

    Jefferis, S.A.

    1997-01-01

    Cut-off walls and caps both may be seriously compromised by small areas of substandard materials or work. Quality assurance/quality control is therefore of crucial importance and the paper sets out the issues that need to be addressed when designing a quality plan for a containment. Consideration is given to the purpose of the containment, the parameters to be controlled, specifications and standards and tests on raw and manufactured materials and on the in-situ containment. It is not the purpose of the paper to give detailed test procedures but rather to identify the questions that must be answered to develop a quality plan

  14. Descriptive study of the quality control in mammography; Estudio descriptivo del control de calidad en mamografia

    Gaona, E.; Perdigon C, G.M.; Casian C, G.A.; Azorin N, J.; Diaz G, J.A.I.; Arreola, M. [UAM, Xochimilco 14000 Mexico D.F. (Mexico)

    2005-07-01

    The goal of mammography is to provide contrast between a lesion that is possible residing within the breast and normal surrounding tissue. Quality control is essential for maintaining the contrast imaging performance of a mammography system and incorporate tests that are relevant in that they are predictive of future degradation of contrast imaging performance. These tests will also be done at frequency that is high enough to intercept most drifts in quality imaging or performance before they become diagnostically significant. The quality control study has as objective to describe the results of the assessment of quality imaging elements (film optical density, contrast (density difference), uniformity, resolution and noise) of 62 mammography departments without quality control program and comparison these results with a mammography reference department with a quality control program. When comparing the results they allow seeing the clinical utility of to have a quality control program to reduce the errors of mammography interpretation. (Author)

  15. Quality control of fireproof coatings for reinforced concrete structures

    Gravit, Marina; Dmitriev, Ivan; Ishkov, Alexander

    2017-10-01

    The article analyzes methods of quality inspection of fireproof coatings (work flow, measuring, laboratory, etc.). In modern construction there is a problem of lack of distinct monitoring for the fire protection testing. There is a description of this testing for reinforced concrete structures. The article shows the results of calculation quality control of hatches as an example of fireproof coating for reinforced concrete structures.

  16. Academic Quality Control in Nigerian Universities: Exploring Lecturers' Perceptions

    Obiekezie, E. O.; Ejemot-Nwadiaro, R. I.; Essien, M. I.; Timothy, A. Essien

    2014-01-01

    The level of job performance, international comparability and competitiveness of Nigerian university graduates are burning issues. Consequently, the academic quality of Nigerian universities has come under severe criticism. Since university lecturers are key players in quality control in universities, this study explored their perceptions of…

  17. Housing tenancy,data management and quality control

    Smeets, J.J.A.M.; Timmermans, H.J.P.

    1993-01-01

    This paper deal s with housing tenancy, data management and quality control. The proposed method is focused on quality characteristics of housing estates in view of rentability risks. It entails a cycle of registration, analysis and implementation of measures. The starting point is the behaviour of

  18. Quality control for diagnostic oral microbiology laboratories in European countries

    Rautemaa-Richardson, R.; van der Reijden, W.A.; Dahlen, G.; Smith, A.J.

    2011-01-01

    Participation in diagnostic microbiology internal and external quality control (QC) processes is good laboratory practice and an essential component of a quality management system. However, no QC scheme for diagnostic oral microbiology existed until 2009 when the Clinical Oral Microbiology (COMB)

  19. Quality control in the storage of potatoes for industrial processing

    Verdijck, G.J.C.; Tijskens, L.M.M.

    2003-01-01

    A novel control structure for a potato storage facility is presented that is directly geared at the optimal preservation of product quality. The quality of the stored potatoes is defined as frying colour that depends on sugar concentration. The optimal storage conditions are estimated using models

  20. Computer-supported quality control in X-ray diagnosis

    Maier, W.; Klotz, E.

    1989-01-01

    Quality control of X-ray facilities in radiological departments of large hospitals is possible only if the instrumentation used for measurements is interfaced to a computer. The central computer helps to organize the measurements as well as analyse and record the results. It can also be connected to a densitometer and camera for evaluating radiographs of test devices. Other quality control tests are supported by a mobile station with equipment for non-invasive dosimetry measurements. Experience with a computer-supported system in quality control of film and film processing is described and the evaluation methods of ANSI and the German industrial standard DIN are compared. The disadvantage of these methods is the exclusion of film quality parameters, which can make processing control almost worthless. (author)

  1. Research Ship Oceanus Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Oceanus Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  2. Research Ship Melville Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Melville Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  3. Research Ship Atlantic Explorer Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Atlantic Explorer Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  4. Research Ship Healy Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Healy Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  5. Research Ship Knorr Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Knorr Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  6. Research Ship Nathaniel B. Palmer Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Nathaniel B. Palmer Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and...

  7. NOAA Ship Delaware II Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Delaware II Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  8. Research Ship Atlantis Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Atlantis Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  9. NOAA Ship Pisces Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Pisces Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System (SAMOS)...

  10. Research Ship Robert Gordon Sproul Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Robert Gordon Sproul Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and...

  11. Research Ship Roger Revelle Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Roger Revelle Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  12. NOAA Ship Fairweather Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Fairweather Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  13. NOAA Ship Bell M. Shimada Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Bell M. Shimada Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  14. NOAA Ship Hi'ialakai Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Hi'ialakai Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  15. Research Ship New Horizon Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship New Horizon Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  16. NOAA Ship Ronald Brown Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Ronald Brown Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  17. Research Ship Aurora Australis Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Aurora Australis Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  18. NOAA Ship Miller Freeman Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Miller Freeman Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  19. NOAA Ship David Starr Jordan Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship David Starr Jordan Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  20. NOAA Ship Henry B. Bigelow Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Henry B. Bigelow Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  1. NOAA Ship Oscar Dyson Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Oscar Dyson Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  2. NOAA Ship Oscar Elton Sette Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Oscar Elton Sette Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  3. Research Ship Kilo Moana Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Kilo Moana Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  4. NOAA Ship Nancy Foster Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Nancy Foster Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  5. NOAA Ship Gordon Gunter Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Gordon Gunter Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  6. Research Ship Southern Surveyor Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Southern Surveyor Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  7. NOAA Ship Rainier Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Rainier Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  8. Research Ship Tangaroa Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Tangaroa Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  9. NOAA Ship Ka'imimoana Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Ka'imimoana Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  10. NOAA Ship Oregon II Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Oregon II Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  11. Preparation and quality control of technetium-99m radiopharmaceuticals

    Samuels, D.L.

    1978-11-01

    Appropriate procedures for the production and quality control of technetium-99m based radiopharmaceuticals in hospital radiopharmacy consistent with the recently published Australian Code of Good Manufacturing Practice are discussed

  12. VERIFICATION TESTING OF AIR POLLUTION CONTROL TECHNOLOGY QUALITY MANAGEMENT PLAN

    This document is the basis for quality assurance for the Air Pollution Control Technology Verification Center (APCT Center) operated under the U.S. Environmental Protection Agency (EPA). It describes the policies, organizational structure, responsibilities, procedures, and qualit...

  13. Calibration and quality control for personnel dose meter

    Wu Rongtao; Zhang Dianqin

    1999-01-01

    Calibration and quality control are the important aspects to assure thermoluminescence dose measurement compliance with the technical standards. The author discussed some problems to implement technical standards and regulations

  14. Mössbauer spectroscopy and quality control in ferrate technology

    Dedushenko, S. K.; Perfiliev, Yu. D.; Kulikov, L. A.

    2013-01-01

    This paper describes some prospective reactants for the ferrate technology of water treatment, the ways of their industrial production and the application of the Mössbauer spectroscopy for their quality control.

  15. Research Ship T. G. Thompson Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship T. G. Thompson Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  16. Research Ship Laurence M. Gould Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Laurence M. Gould Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  17. NOAA Ship Okeanos Explorer Underway Meteorological Data, Quality Controlled

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Okeanos Explorer Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  18. Physical chemical quality control of the molybdenum technetium generator

    Olive, E.; Cruz, J.; Isaac, M.; Gamboa, R.; D'Alessandro, K.; Desdin, L.F.

    1995-01-01

    Comparative operational procedure imported molybdenum technetium generators have been made. Procedures for determination of chemical, radiochemical and radionuclidic purities that may be applied in Hospital's laboratories and in the quality control of generators production are developed

  19. Quality controls of radiopharmaceuticals used in nuclear medicine

    Gomez de Castiglia, S.I.; Fraga de Suarez, A.H.; Mitta, A.E.A.

    1981-01-01

    Chromatographic quality controls for Tc-99m; In-113m; I-131; Tl-201 and Ga-67 radiopharmaceuticals are described. Moreover, a chromatographic system which allows to separate different radiopharmaceuticals from In-113m is pointed out. (author) [es

  20. Quality control of plane and tomographic gamma cameras

    Moretti, J.L.; Roussi, A.

    1993-01-01

    In this article, the authors present different methods of gamma camera quality control in matters of uniformity, spatial resolution, spatial linearity, sensitivity, energy resolution, counting rate performance, SPECT parameters. The authors refer mainly to NEMA standards. 14 figs., 8 tabs

  1. Quality control of radiation therapy in clinical trials

    Kramer, S.; Lustig, R.; Grundy, G.

    1983-01-01

    The RTOG is a group of participating institutions which has a major interest in furthering clinical radiation oncology. They have formulated protocols for clinical investigation in which radiation therapy is the major modality of treatment. In addition, other modalities, such as chemotherapy, radiation sensitizers, and hyperthermia, are used in combined approach to cancer. Quality control in all aspects of patient management is necessary to insure quality data. These areas include evaluation of pathology, physics, and dosimetry, and clinical patient data. Quality control is both time consuming and expensive. However, by dividing these tasks into various levels and time frames, by using computerized data-control mechanisms, and by employing appropriate levels of ancillary personnel expertise, quality control can improve compliance and decrease the cost of investigational trials

  2. Six Sigma Quality Management System and Design of Risk-based Statistical Quality Control.

    Westgard, James O; Westgard, Sten A

    2017-03-01

    Six sigma concepts provide a quality management system (QMS) with many useful tools for managing quality in medical laboratories. This Six Sigma QMS is driven by the quality required for the intended use of a test. The most useful form for this quality requirement is the allowable total error. Calculation of a sigma-metric provides the best predictor of risk for an analytical examination process, as well as a design parameter for selecting the statistical quality control (SQC) procedure necessary to detect medically important errors. Simple point estimates of sigma at medical decision concentrations are sufficient for laboratory applications. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Suggestion for improvement of PET quality control tests in Brazil

    Ferreira, Fernanda C.L.; Magalhaes, Cinthia M.S.; Souza, Divanizia N.

    2009-01-01

    Nowadays nuclear medicine has a considerable importance among the other medical specialties. This medical specialty utilizes high-tech equipment for imaging in the diagnosis, obtaining information on the clinical functionality of organs and systems of the human body through the use of radioisotopes . In view of the importance of guaranteeing the image quality in SPECT and PET systems, enabling patients not repeat exams due to lack of quality control of equipment used in nuclear medicine, this paper aims to present a possible suggestion to update the quality control tests needed for quality assurance of nuclear medicine services. They were considered the requirements of the National Commission of Nuclear Energy (CNEN) and the National Health Surveillance Agency (ANVISA) in Brazil. The minimum requirements to be defined for inclusion of quality control tests on PET in the standard CNEN are extremely important because they will guide the evaluation of PET systems, determining the quality control tests to be performed. And those tests for PET will be a regulatory requirement by the CNEN and ANVISA. As the National Health Surveillance Agency has already publication of RDC 38 with recommendations for services of nuclear medicine. This study will continue with evaluation of PET systems and presenting the tests of quality control with additional objects and simulators to ensure safety in PET systems have not standardized in nuclear medicine services in Brazil. (author)

  4. Production control system specified quality sausage products

    A. V. Tokarev

    2016-01-01

    Full Text Available The problem of management of production target in technological system of production of sausages of the set quality is considered in article. Decomposition of technological system is considered. Functions of management are allocated: formation of an optimum compounding of forcemeat, expert analysis of a compounding, laboratory analysis of a compounding and its statement. Information technology of interaction of these functions is offered. The mathematical problem definition of finding of an optimum compounding meat product with use of possible substitutes of ingredients is presented. This mathematical problem is a classical linear programming problem whose solution has the standard program. Since the manufacture of the finished product are various nonlinear effects are taken into account at the present time it is practically impossible, the methodology provided in this operation "Expert analysis of the formulation" and "Laboratory analysis of the finished product." An example of calculating the optimum alternative base recipe "Sausages “Viennese with cheese”" TS 9213-010-40155161-2002. For an alternative formulation demands were made at a cost of meat, the ingredient composition, as well as the final product organoleptic and physic-chemical indicators should comply with regulatory requirements "Sausages “Viennese with cheese”" TS 9213-010-40155161-2002. Indicator acid activity (pH calculated stuffing formulation should be in the range 6.0-6.3. As a partial replacement for the main raw material have been proposed acceptable substitutes. It was necessary to calculate on the basis of the formulation "Sausages “Viennese with cheese”" TS 9213-010-40155161-2002 optimal price and quality alternative formulation. As a result of depreciation of the value of alternative stuffing recipe was 14,5 % when all of the restrictions on the consumer properties. The proposed information technology implemented in the software package "Multi

  5. Quality control of injection moulded micro mechanical parts

    Gasparin, Stefania; Tosello, Guido; Hansen, Hans Nørgaard

    2009-01-01

    Quality control of micro components is an increasing challenge. Smaller mechanical parts are characterized by smaller tolerance to be verified. This paper focuses on the dimensional verification of micro injection moulded components selected from an industrial application. These parts are measured...... using an Optical Coordinate Measuring Machine (OCMM), which guarantees fast surface scans suitable for in line quality control. The uncertainty assessment of the measurements is calculated following the substitution method. To investigate the influence parameters in optical coordinate metrology two...

  6. Quality control of rain data used for urban runoff systems

    Jørgensen, H. K.; Rosenørn, S.; Madsen, Henrik

    1998-01-01

    for collection and quality control of rain data from a network of tipping bucket rain gauges in Denmark carried out by the Danish Meteorological Institute. During rain, the RIMCO gauge counts the number of tips teach of 0.2 mm of precipitation) every minute, The quality control of the rain data includes...... an automatic and a manual bit marking, where the automatic control basically is pointing out minutes with extreme intensities. In the manual control, the maximum intensities as well as the daily totals of precipitation are inspected, using weather charts, intensity plots and precipitation sums of nearby...

  7. COLLABORATIVE TRIAL AND QUALITY CONTROL IN CHEMICAL ANALYSIS

    Narsito Narsito

    2010-06-01

    Full Text Available Abstract                                                             This paper deals with some practical problems related to the quality of analytical chemical data usually met in practice. Special attention is given to the topic of quality control in analytical chemistry, since analytical data is one of the primary information from which some important scientifically based decision are to be made. The present paper starts with brief description on some fundamental aspects associated with quality of analytical data, such as sources of variation of analytical data, criteria for quality of analytical method, quality assurance in chemical analysis. The assessment of quality parameter for analytical method like the use of standard materials as well as standard methods is given. Concerning with the quality control of analytical data, the use of several techniques, such as control samples and control charts, in monitoring analytical data in quality control program are described qualitatively.  In the final part of this paper, some important remarks for the preparation of collaborative trials, including the evaluation of accuracy and reproducibility of analytical method are also given Keywords: collaborative trials, quality control, analytical data Abstract                                                             This paper deals with some practical problems related to the quality of analytical chemical data usually met in practice. Special attention is given to the topic of quality control in analytical chemistry, since analytical data is one of the primary information from which some important scientifically based decision are to be made. The present paper starts with brief description on some fundamental aspects associated with quality of analytical data, such as sources of variation of analytical data, criteria for quality of

  8. Quality control in a modern XRF laboratory

    Grigolato, E.

    2002-01-01

    Full text: In the last twenty years manufacturers have improved instruments significantly. Many of these advances have come from the computing power now available using a PC. Unfortunately, now in many laboratories, the senior analyst is responsible for multiple instruments and may have little experience in XRF. It is now common for instruments to be calibrated by consultants and used in a black box mode. The session will look at a range of tools for monitoring and controlling your XRF from date of installation, thru calibration, routine use and maintenance. Discussion of user problems is an integral part of the session. Copyright (2002) Australian X-ray Analytical Association Inc

  9. Production process and quality control for the HTTR fuel

    Yoshimuta, S.; Suzuki, N.; Kaneko, M.; Fukuda, K.

    1991-01-01

    Development of the production and inspection technology for High Temperature Engineering Test Reactor (HTTR) fuel has been carried out by cooperative work between Japan Atomic Energy Research Institute (JAERI) and Nuclear Fuel Industries, Ltd (NFI). The performance and the quality level of the developed fuel are well established to meet the design requirements of the HTTR. For the commercial scale production of the fuel, statistical quality control and quality assurance must be carefully considered in order to assure the safety of the HTTR. It is also important to produce the fuel under well controlled process condition. To meet these requirements in the production of the HTTR fuel, a new production process and quality control system is to be introduced in the new facilities. The main feature of the system is a computer integrated control system. Process control data at each production stage of products and semi-products are all gathered by terminal computers and processed by a host computer. The processed information is effectively used for the production, quality and accountancy control. With the aid of this system, all the products will be easily traceable from starting materials to final stages and the statistical evaluation of the quality of products becomes more reliable. (author). 8 figs

  10. [Our experience with outside laboratory quality control].

    Dochev, D; Arakasheva, V; Nashkov, A; Tsachev, K

    1979-01-01

    The results from the national outside laboratory qualitative control of the clinical diagnostic laboratory investigations for the period September 1975 -- May 1977 were described. The following interlaboratory discrepancy was found on base of a systematic analysis of the data from the last two ring-like check-ups, November 1976 and May 1977, exressed by the variation coefficient (V.C. %); total protein, sodium, potassium and chlorides -- under 10%; cholesterol, urea and total fats -- between 10 and 20%; calcium, phosphorus, iron and creatinine -- over 20%. The highest per cent of admissible results are found with total protein -- to 85%; cholesterol -- to 70.38%; glucosa -- to 73.17%, urea -- to 69.23%, potassium -- to 59.46%, chlorides -- to 57.9%. With sodium, phosphorus, calcium, iron creatinine and uric acid the "admissibility" fluctuates about or under 50 per cent. The values of the qualitative-control indices discussed are comparable with the values obtained from them in the interlaboratory comparisons of other countries.

  11. Research review: Indoor air quality control techniques

    Fisk, W.J.

    1986-10-01

    Techniques for controlling the concentration of radon, formaldehyde, and combustion products in the indoor air are reviewed. The most effective techniques, which are generally based on limiting or reducing indoor pollutant source strengths, can decrease indoor pollutant concentrations by a factor of 3 to 10. Unless the initial ventilation rate is unusually low, it is difficult to reduce indoor pollutant concentrations more than approximately 50% by increasing the ventilation rate of an entire building. However, the efficiency of indoor pollutant control by ventilation can be enhanced through the use of local exhaust ventilation near concentrated sources of pollutants, by minimizing short circuiting of air from supply to exhaust when pollutant sources are dispersed and, in some situations, by promoting a displacement flow of air and pollutants toward the exhaust. Active air cleaning is also examined briefly. Filtration and electrostatic air cleaning for removal of particles from the indoor air are the most practical and effective currently available techniques of air cleaning. 49 refs., 7 figs

  12. Quality control and quality assurance in individual monitoring of ionising radiations

    Dutt, J.C.; Lindborg, L.

    1994-01-01

    This paper describes the programmes and approaches that are to be considered in developing and introducing quality assurance and quality control procedures in individual monitoring services. Quality assurance and quality control in individual monitoring services are essential to maintain quality and are of increasing importance in order to meet the requirements of national regulations and international standards and guidelines. It is recommended here that all organisations offering individual monitoring services should run their services based on the principles of Quality System as given in the European Standard EN45001 and maintain a property resources QA/QC programme as an integral part of their operations. All aspects of QA/QC in individual monitoring services starting from the initial selection, installation, calibration, and operation to the final products including dose reporting, dose record keeping, dealing with customers' complaints and product liability issues have been discussed. (Author)

  13. Global environmental controls of diversity in large herbivores

    Olff, Han; Ritchie, Mark E.; Prins, Herbert H.T.

    2002-01-01

    Large mammalian herbivores occupy half of the earth's land surface and are important both ecologically and economically, but their diversity is threatened by human activities. We investigated how the diversity of large herbivores changes across gradients of global precipitation and soil fertility.

  14. Coordination and Control of Globally Distributed Software Projects

    P.C. van Fenema (Paul)

    2002-01-01

    textabstractRecently, software development and implementation projects have globalized at a rapid pace. Companies in North America, Europe, and the Far East are beginning to integrate international Information Technology (IT) resources to support operations across the globe. Offshore IT services

  15. Quality control of scintillation cameras (planar and SPECT)

    Shaekhoon, E.S.

    2008-01-01

    Regular quality control is one of the corner stones of nuclear medicine and a prerequisite for adequate diagnostic imaging. Many papers have been published on quality control of planar and SPECT imaging system up to now, however only minor attenuation has been given to the assessment of the performance of imaging systems. In this research we are going to discuss a comprehensive set of test procedures including regular quality control. Our purpose is to go through analysis of the methods and results then to test our hypothesis which state that there is strong relationship between regular and proper evaluation of quality control and the continuity of better medical services in nuclear medicine department. The selection of the tests is discussed and the tests are described, then results are presented. In addition action thresholds are proposed. The quality control tests can be applied to systems with either a moving detector or a moving image table, and to both detector with a large field of view and detectors with a small field of view. The tests presented on this research do not required special phantoms or sources other than those used for quality control of stationary gamma camera and SPECT. They can be applied for acceptance testing and for performance testing in a regular quality assurance program. The data has been evaluated based on me diso software in comparing with IAEA expert software and system specification within the reference values. Our final results confirm our hypothesis, there are some comments about the characteristics and performance of this system that being observed and solved, then a departmental protocol for routine quality control (Q.C) has being established.(Author)

  16. Production And Quality Control Of Radiopharmaceutical 18F-FDG

    Dinh Thi Bich Lieu; Nguyen Van Si; Vu Van Tien

    2011-01-01

    18 F-FDG is a radiopharmaceutical for imaging diagnosis with PET/CT in Nuclear Medicine. Criteria of injection pharmaceuticals are the highest standards. So, quality assurance and quality control must be followed very strictly. The selection of the procedure for 18 F-FDG has based on several criteria: high chemical efficiency, short synthesis time, toxic component free and etc. The quality control of 18 F-FDG consist many fields such as: nuclear physic (nuclear purity), radiochemistry (radionuclear purity, radiochemical purity), chemistry (chemical purity), radiation measurement (half life), microbiology (pyrogen, endotoxin), etc. which is following USP, BP or EP. (author)

  17. Analytic Methods Used in Quality Control in a Compounding Pharmacy.

    Allen, Loyd V

    2017-01-01

    Analytical testing will no doubt become a more important part of pharmaceutical compounding as the public and regulatory agencies demand increasing documentation of the quality of compounded preparations. Compounding pharmacists must decide what types of testing and what amount of testing to include in their quality-control programs, and whether testing should be done in-house or outsourced. Like pharmaceutical compounding, analytical testing should be performed only by those who are appropriately trained and qualified. This article discusses the analytical methods that are used in quality control in a compounding pharmacy. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  18. Concept and realization of quality control in FRG

    Odoj, R.; Martens, B.R.; Warnecke, E.

    1987-01-01

    Radioactive waste packages to be disposed of in FRG must meet the waste acceptance requirement of the repository. Compliance with the waste acceptance requirements must be checked by a quality control. Fourteen relevant properties are necessary to be assayed. The quality control group supports the observance of the waste acceptance requirements by the following measures: -checking of the documentation of the waste producers; -random tests at conditioned radioactive wastes; -qualification of conditioning processes; -control of the qualified processes by inspections. The relevant properties of disposal are termed and their checking by non-destructive and if necessary destructive test methods will be explained as well as quality control by process control, i.e. qualification of conditioning processes by instrumentation and documentation. The mobile and stationary testing facilities will be outlined

  19. Managing Food Quality Risk in Global Supply Chain: A Risk Management Framework

    Pablo Jose Arevalo Chavez

    2012-04-01

    Full Text Available Today, the food sector is one of the sectors most vulnerable to intentional contamination by debilitating agents [1]. Some cases of contaminated food have indicated that product quality risk is one of the vulnerabilities in the global supply chain. A series of company scandals, affecting reputation and causing the recall of products and increasing costs have hit the food industry. The obvious problem is that even a minor incident in one part of the chain can have disastrous effects on other parts of the supply chain. Thus, risks are transmitted through the chain. Even though the dangers from members in the supply chain are small, the cumulative effect becomes significant. The aim of this study is to propose an integrated supply chain risk management framework for practitioners that can provide directions for how to evaluate food quality risk in the global supply chain. For validating the proposed model in‐depth, a case study is conducted on a food SME distributor in Central America. The case study investigates how product quality risks are handled according to the proposed framework.

  20. Quality control of conventional radiographic facilities in Kinshasa

    Woto, M.L.; Lukanda, M.V.; Mulumba, L.C.P.; Palangu

    2009-01-01

    The continuous development of medical applications of ionizing radiation, due to the benefit derived by diagnostic or therapeutic patients, their diversity, ease of implementation, explains the importance of medical exposure. The latter is currently the leading cause of human exposure to artificial origin. The purpose of this study is to contribute to the optimization of radiographic facilities in the city of Kinshasa. This study has revealed that city of Kinshasa has an average of 122 medical training with conventional radiology facilities distributed in six districts of health. Of the 122 facilities, only 30 (or 24.59%) are controlled from the point of view of quality assurance. Some generators and X-ray tubes are respectively controlled adjustment and de centered, and other devices are cannibalized. So, nationally and particularly in Kinshasa, quality control equipment and diagnostic facilities is at a generally delayed compared with international recommendations of X W. Major efforts must be made at government level to raise awareness and establish a quality assurance program in diagnostic radiology. An awareness of the entire medical profession and the competent administrative authorities of medical devices could be beneficial to the quality of care delivered to patients, limiting radiation exposure and improving image quality and only the financial balance of the health sector. The delivery of quality care passes through the justification of acts, the development and dissemination of good practice references and the establishment of quality control radiological installations.