WorldWideScience

Sample records for gleeble torsion testing

  1. Numerical Simulation of Gleeble Torsion Testing of HSLA-65 Steel

    National Research Council Canada - National Science Library

    Forrest, David R; Sinfield, Matthew F

    2008-01-01

    NSWCCD has used a Gleeble thermomechanical simulator as a tool to provide carefully controlled deformation cycles on metallurgical samples to study the properties and physics of friction stir welds...

  2. Gleeble Testing of Tungsten Samples

    Science.gov (United States)

    2013-02-01

    length of the sample. Density measurements were also taken before and after testing using Archimedes principle . Samples were also tested at room...commonly seen in body centered cubic (BCC) metals and can be attributed to dislocation mobility theories (8). The basic principles are that the...processing of nano-tungsten and nano-tungsten alloys to achieve superior strength, ductility, and fracture toughness for room temperature applications

  3. Numerical Simulation of Gleeble Torsion Testing of HSLA-65 Steel

    National Research Council Canada - National Science Library

    Forrest, David R; Sinfield, Matthew F

    2008-01-01

    ... to the extreme thermal and strain field gradients within a friction stir weld. This allows us to independently vary strain and temperature with time in ways that may not even be possible under normal friction stir welding conditions...

  4. Numerical Simulation of Gleeble Torsion Testing of HSLA-65 Steel (CD-ROM)

    National Research Council Canada - National Science Library

    Forrest, David R; Sinfield, Matthew F

    2008-01-01

    ... to the extreme thermal and strain field gradients within a friction stir weld. This allows us to independently vary strain and temperature with time in ways that may not even be possible under normal function stir welding conditions...

  5. Torsion testing of bed joints

    DEFF Research Database (Denmark)

    Hansen, Klavs Feilberg; Pedersen, Carsten Mørk

    2008-01-01

    be carried out directly in a normal testing machine. The torsion strength is believed to be the most important parameter in out-of-plane resistance of masonry walls subjected to bending about an axis perpendicular to the bed joints. The paper also contains a few test results from bending of small walls about...... an axis perpendicular to the bed joints, which indicate the close connection between these results and results from torsion tests. These characteristics make the torsion strength well suited to act as substitute parameter for the bending strength of masonry about an axis perpendicular to the bed joints....

  6. University of Florida Torsion Pendulum for Testing Key LISA Technology

    Science.gov (United States)

    Apple, Stephen; Chilton, Andrew; Olatunde, Taiwo Janet; Hillsberry, Daniel; Parry, Samantha; Ciani, Giacomo; Wass, Peter; Mueller, Guido; Conklin, John

    2018-01-01

    This presentation will describe the design and performance of a new torsion pendulum at the University of Florida used for testing inertial sensors and associated technologies for use in space – based gravitational wave observatories and geodesy missions. In particular this new torsion pendulum facility is testing inertial sensors and associated technology for the upcoming LISA (laser interferometer space antenna) space-based gravitational wave observatory mission. The torsion pendulum apparatus is comprised of a suspended cross bar assembly that has LISA test mass mockups at each of its ends. Two of the test mass mockups are enclosed by capacitive sensors which provide actuation and position sensing. The entire assembly is housed in a vacuum chamber. The pendulum cross-bar converts rotational motion of the test masses about the suspension fiber axis into translational motion. The 22 cm cross bar arm length along with the extremely small torsional spring constant of the suspension fiber results in a near free fall condition in the translational degree-of-freedom orthogonal to both the member and the suspension fiber. The test masses are electrically isolated from the pendulum assembly and their charge is controlled via photoemission using fiber coupled UV LEDS. Position of the test masses is measured using both capacitive and interferometric readout. The broadband sensitivity of the capacitive readout and laser interferometer readout is 30 nm/√Hz and 0.5 nm/√Hz respectively. The performance of the pendulum measured in equivalent acceleration noise acting on a LISA test mass is approximately 3 × 10-13 ms-2/√Hz at 2 mHz. This presentation will also discuss the design and fabrication of a flight-like gravitational reference sensor that will soon be integrated into the torsion pendulum facility. This flight-like GRS will allow for noise performance measurements in a more LISA-like configuration.

  7. Test rig for tension-torsion at high temperature

    International Nuclear Information System (INIS)

    Policella, H.; Pacou, D.

    1988-01-01

    An improved version of Tension-Torsion test rig at high temperature (1,000 0 C) is described. Damage under Multiaxial loading, experimental methods have been developed concerning both extensometric measures and induction heating application. First experimental results are presented for AISI316 nuclear steel at 600 0 C and INCO718 alloy at 650 and 550 0 C. During these tests, the Multiaxiality effect is investigated following proportional or non proportional strain (or stress) paths (phase or out of phase) [fr

  8. Plastic Behavior and Fracture of Aluminum and Copper in Torsion Tests

    International Nuclear Information System (INIS)

    Bressan, Jose Divo

    2007-01-01

    Present work investigates the plastic behavior, work hardening and the beginning of plastic instabilities, of cylindrical specimens deformed by high speed cold plastic torsion tests and at low speed tensile test. The tests were carried out in a laboratory torsion test equipment and an universal tensile test machine. The tensile tests were performed at room temperature in an universal testing machine at low strain rate of 0.034/s. Experimental torsion tests were carried out at constant angular speed that imposed a constant shear strain rate to the specimen. In the tests, the rotation speed were set to 62 rpm and 200 rpm which imposed high strain rates of about 2/s and 6.5/s respectively. The torsion tests performed at room temperature on annealed commercial pure copper and aluminum. Two types of torsion specimen for aluminum were used: solid and tubular. The solid aluminum specimen curves presented various points of maximum torque. The tubular copper specimens showed two points of maximum. Shear bands or shear strain localization at specimen were possibly the mechanism of maximum torque points formation. The work hardening coefficient n and the strain rate sensitivity parameter m were evaluated from the equivalent stress versus strain curve from tensile and torsion tests. The n-value remained constant whereas the m-value increased ten folds for aluminum specimens: from tensile test m= 0.027 and torsion test m= 0.27. However, the hardening curves were sigmoidal

  9. Sporadic adult onset primary torsion dystonia is a genetic disorder by the temporal discrimination test.

    LENUS (Irish Health Repository)

    Kimmich, Okka

    2012-02-01

    Adult-onset primary torsion dystonia is an autosomal dominant disorder with markedly reduced penetrance; patients with sporadic adult-onset primary torsion dystonia are much more prevalent than familial. The temporal discrimination threshold is the shortest time interval at which two stimuli are detected to be asynchronous and has been shown to be abnormal in adult-onset primary torsion dystonia. The aim was to determine the frequency of abnormal temporal discrimination thresholds in patients with sporadic adult-onset primary torsion dystonia and their first-degree relatives. We hypothesized that abnormal temporal discrimination thresholds in first relatives would be compatible with an autosomal dominant endophenotype. Temporal discrimination thresholds were examined in 61 control subjects (39 subjects <50 years of age; 22 subjects >50 years of age), 32 patients with sporadic adult-onset primary torsion dystonia (cervical dystonia n = 30, spasmodic dysphonia n = 1 and Meige\\'s syndrome n = 1) and 73 unaffected first-degree relatives (36 siblings, 36 offspring and one parent) using visual and tactile stimuli. Z-scores were calculated for all subjects; a Z > 2.5 was considered abnormal. Abnormal temporal discrimination thresholds were found in 1\\/61 (2%) control subjects, 27\\/32 (84%) patients with adult-onset primary torsion dystonia and 32\\/73 (44%) unaffected relatives [siblings (20\\/36; 56%), offspring (11\\/36; 31%) and one parent]. When two or more relatives were tested in any one family, 22 of 24 families had at least one first-degree relative with an abnormal temporal discrimination threshold. The frequency of abnormal temporal discrimination thresholds in first-degree relatives of patients with sporadic adult-onset primary torsion dystonia is compatible with an autosomal dominant disorder and supports the hypothesis that apparently sporadic adult-onset primary torsion dystonia is genetic in origin.

  10. Recrystallization of niobium stabilized ferritic stainless steel during hot rolling simulation by torsion tests

    Directory of Open Access Journals (Sweden)

    Flávia Vieira Braga

    2016-01-01

    Full Text Available The aim of this study was to investigate the effect of finishing hot rolling temperature in promoting interpass recrystallization on a Nb-stabilized AISI 430 ferritic stainless steel. Torsion tests were performed in order to simulate the Steckel mill rolling process by varying the temperature ranges of the finishing passes. Interrupted torsion test were also performed and interpass recrystallization was evaluated via optical microscopy and electron backscatter diffraction (EBSD. As a result of this work, it has been established, within the restrictions of a Steckel mill rolling schedule, which thermomechanical conditions mostly favor SRX.

  11. Determination of energy dissipation and process instability in various alloys on the basis of plastometric tests

    Directory of Open Access Journals (Sweden)

    T. Kubina

    2013-07-01

    Full Text Available Energy dissipation and areas of process instability were investigated in two alloys. The first one was brass, the second one was the steel 9 Cr (P91. The tests were performed on torsion plastometer Setaram and on compression plastometer Gleeble. In the case of the steel 9 Cr identical heat was tested on both plastometers. The resulting 2D or 3D process maps indicate suitable areas of forming temperatures, magnitudes of deformation and strain rates.

  12. Analysis of new Gleeble tensile specimen design for hot stamping application

    Directory of Open Access Journals (Sweden)

    Ganapathy Manikandan

    2015-01-01

    Full Text Available Hot tensile testing is useful to understand the material behavior at elevated temperatures. Hence it is of utmost importance that the test condition is accurate enough to derive stress-strain data in fully austenitic state and to ensure homogeneous deformation throughout the gauge length of the specimen. But present limitation of standard Gleeble hot tensile sample geometry could not be used to achieve a uniform temperature distribution along the gauge section, thus creating errors of experimental data. In order to understand the effect of sample geometry on temperature gradient within the gauge section coupled electrical-thermal and thermo-mechanical finite element analysis has been carried out using Abaqus, with the use of viscoplastic damage constitutive equations presented by Li [1]. Based on the experimental study and numerical analysis, it was observed that the new sample geometry introduced by Abspoel [2], is able to achieve a better uniformity in temperature distribution along the gauge length; The temperature deviation along the gauge length within 25 ∘C during soaking and 5 ∘C after cooling and onset of deformation; also the strain deformation is found to be almost homogeneous.

  13. A novel torsional exciter for modal vibration testing of large rotating machinery

    Science.gov (United States)

    Sihler, Christof

    2006-10-01

    A novel exciter for applying a dynamic torsional force to a rotating structure is presented in this paper. It has been developed at IPP in order to perform vibration tests with shaft assemblies of large flywheel generators (synchronous machines). The electromagnetic exciter (shaker) needs no fixture to the rotating shaft because the torque is applied by means of the stator winding of an electrical machine. Therefore, the exciter can most easily be applied in cases where a three-phase electrical machine (a motor or generator) is part of the shaft assembly. The oscillating power for the shaker is generated in a separate current-controlled DC circuit with an inductor acting as a buffer storage of magnetic energy. An AC component with adjustable frequency is superimposed on the inductor current in order to generate pulsating torques acting on the rotating shaft with the desired waveform and frequency. Since this torsional exciter does not require an external power source, can easily be installed (without contact to the rotating structure) and provides dynamic torsional forces which are sufficient for multi-megawatt applications, it is best suited for on-site tests of large rotating machinery.

  14. Estimation of the hot extrusion process pressure cycle of zircaloy tubes by torsion and compression tests

    International Nuclear Information System (INIS)

    Bianchi, D; Banchik, D.A; Gonzalez, I; Dagradi, J; Rodriguez, C

    2002-01-01

    In the production of Zircaloy-4 tubes for nuclear reactors, the first semi-processed tubular form is obtained using the extrusion process. Empirical equations are normally used, which can be applied to extrusion with axial symmetry, or analytical ones are used such as Seibel's equation to evaluate the extrusion process based on the material flow tension. When we use the flow tension corresponding to the mean value of the velocity of extrusion deformation, the extrusion pressure is significantly underestimated, with relation to the experimentally measured pressure. This is because of the flow tension's heavy dependence on the velocity of deformation, which is typical of commercial zirconium alloys. Therefore, the pressure was estimated by calculating the power dissipated during the deformation assuming a velocity field of homogenous deformation in each stage of deformation but without considering friction forces between the work and the extrusion matrix. The flow tension for the torsion tests performed are compared with the results obtained by compression as reported in the literature. These results are compared with four extrusion sequences carried out with different: reduction rates, temperatures, and deformation velocities. The flow tension from the compression test presents greater tension values than those estimated by the torsion test. The origin of these differences is discussed and the conclusion is that they can be attributed to the different crystallography textures generated in both tests. Once the correction is made for the texture variation, the flow tension values evaluated with both testing types in samples of Zircaloy-4 are the same. The peculiarities of each test in relation to the extrusion process are discussed. Despite the very simplified hypotheses that were assumed, the extrusion pressures calculated with the compression and torsion flow tension results, considering their dependence on the speed of deformation and temperature variation during

  15. Mechanical design of the University of Florida Torsion Pendulum for testing the LISA Gravitational Reference Sensor

    Science.gov (United States)

    Shelley, Ryan; Chilton, Andrew; Olatunde, Tawio; Ciani, Giacomo; Mueller, Guido; Conklin, John

    2014-03-01

    The Laser Interferometer Space Antenna (LISA) requires free falling test masses, whose acceleration must be below 3 fm/s2/rtHz in the lower part of LISA's frequency band ranging from 0.1 to 100 mHz. Gravitational reference sensors (GRS) house the test masses, shield them from external disturbances, control their orientation, and sense their position at the nm/rtHz level. The GRS torsion pendulum is a laboratory test bed for GRS technology. By decoupling the system of test masses from the gravity of the Earth, it is possible to identify and quantify many sources of noise in the sensor. The mechanical design of the pendulum is critical to the study of the noise sources and the development of new technologies that can improve performance and reduce cost. The suspended test mass is a hollow, gold-coated, aluminum cube which rests inside a gold-coated, aluminum housing with electrodes for sensing and actuating all six degrees of freedom. This poster describes the design, analysis, and assembly of the mechanical subsystems of the UF Torsion Pendulum.

  16. Mechanical properties of reactor pressure vessel steels studied by static and dynamic torsion tests

    International Nuclear Information System (INIS)

    Munier, A.; Maamouri, M.; Schaller, R.; Mercier, O.

    1993-01-01

    Internal friction measurements and torsional plastic deformation tests have been performed in reactor pressure vessel steels (unirradiated, irradiated and irradiated/annealed specimens). The results of these experiments have been interpreted with help of transmission electron microscopy observations (conventional and in situ). It is shown how the interactions between screw dislocations and obstacles (Peierls valleys, impurities and precipitates) could explain the low temperature hardening and the irradiation embrittlement of ferritic steels. In addition, it appears that the nondestructive internal friction technique could be used advantageously to follow the evolution of the material properties under irradiation, as for instance the irradiation embrittlement of the reactor pressure vessel steels. (orig.)

  17. The evaluation of the neck torsion test in subjective examinations of patients with vertigo and/or hearing loss.

    Science.gov (United States)

    Niewiadomski, Piotr; Zielińska-Bliźniewskaw, Hanna; Miloński, Jarosław; Pietkiewicz, Piotr; Olszewski, Jurek

    2015-01-01

    The aim of this work was to evaluate the diagnostic value of the neck torsion test in VNG, Doppler ultrasonography and brainstem auditory evoked potentials in patients with vertigo and/or hearing loss due to intracranial vascular malformations. The study covered 47 patients, 30 female and 17 male (mean age, 55.5 years; range, 19-74 years) with vertigo and/or hearing disorders and the asymmetry of vertebral arteries. Each patient underwent a subjective examination, an otolaryngological examination, otoneurological diagnostics, VNG with gaze tracking in the straight ahead position and in the 600 left and right neck torsion, the neck torsion test, audiological diagnostics including I-, III- and V-wave latency of the brainstem evoked potentials in the straight ahead position and the right ear stimulation in the 600 right neck torsion and the left ear stimulation in the neck torsion to the left, Doppler ultrasonography with measuring the diameter of vertebral arteries and the velocity of the blood flow in these vessels with the use of the neck torsion test. In own study, in VNG, the positive neck torsion test was observed in 76.5% of the study patients, while square waves in both directions were found in 46.5% and in one direction in 10.6%. Cervical nystagmus was noticed in 19.1% of these patients. In the auditory evoked potentials test, the differences in I-, III- and V-wave latency time were not statistically significant, either at rest or in the neck torsion. In the Doppler ultrasound examination, the asymmetry of vertebral arteries were present (below 25%) in 7 women (14.9%) and 4 men (8.5%), whereas large asymmetries (above 25%) were observed in 23 women (48.9%) and 13 (27.7%) men (range, 25% - 215%) and was statistically insignificant. The resting blood flow velocity in vertebral arteries of large asymmetries, both in systole and diastole heart phases, was significantly higher in the artery with larger asymmetry. The neck torsion test can be diagnostically useful

  18. Abutment screw loosening of endosseous dental implant body/abutment joint by cyclic torsional loading test at the initial stage.

    Science.gov (United States)

    Katsuta, Yasuhiro; Watanabe, Fumihiko

    2015-01-01

    Cyclic torsional loading tests were carried out in the laboratory using various implant systems, in order to clarify differences between the systems in loosening of abutment screws. Six samples from six commercially available abutment systems were used, giving a total of 36 samples. Four of the systems used internal connections, and two used external connections. The abutment screw for each system was tightened to a torque value specified by the manufacturer, and after 5 min, the loosening torque was measured using a digital torque meter. Measurements were taken twice, and a second measurement was taken as a reference value. A cyclic torsional loading test with 100,000 cycles was performed on the sample, and the loosening torque was again measured after the test. In conclusion, loosening of the abutment screw occurred as a result of cyclic torsional loading, and the degree of loosening varied with each implant system.

  19. Nonuniform Shear Strains in Torsional Kolsky Bar Tests on Soft Specimens

    Science.gov (United States)

    2015-02-01

    this problem can be inferred from the paper [Hill and Lee 1989], which treats a slightly different problem, namely combined compression and torsion of...well before the torsional stress increases. This effect cannot be due to bending waves or longitudinal waves that might be generated in the incident...292. [Hill and Lee 1989] J. M. Hill and A. I. Lee, “ Combined compression and torsion of circular cylindrical pads of rubber”, J. Mech. Phys. Solids 37:2

  20. Loss of bone strength after intramedullary nailing. Torsion tests of tibial osteotomies in rabbits.

    Science.gov (United States)

    Kaartinen, E; Paavolainen, P; Holmström, T; Slätis, P

    1985-12-01

    Rigid intramedullary nailing was used in 75 rabbits to stabilize a transverse osteotomy of the midshaft of the tibia. In 36 additional rabbits intramedullary nailing was performed without osteotomy. No additional external immobilization was used postoperatively. After removal of the nail the mechanical strength of the tibiofibular bones was tested torsiometrically in 30 osteotomized and 18 non-osteotomized animals from 3 to 24 weeks after the operation. At 3 weeks the torsional load fractured all osteotomized bones through the osteotomy line. At later stages a spiral fracture occurred either crossing or close to the osteotomy area, usually distal to the tibiofibular junction. The increase in mechanical strength of the osteotomized bones reached a maximum at 6 weeks and then decreased. The strength of the non-osteotomized nailed bones also decreased slightly. The results suggest that rigid intramedullary nailing, although providing good conditions for early consolidation of experimental osteotomy, leads secondarily to deterioration of the mechanical properties of tubular bone.

  1. Design, fabrication and test of lightweight shell structure. [axial compression loads and torsion stress

    Science.gov (United States)

    Lager, J. R.

    1975-01-01

    A cylindrical shell structure 3.66 m (144 in.) high by 4.57 m (180 in.) diameter was designed using a wide variety of materials and structural concepts to withstand design ultimate combined loading 1225.8 N/cm (700 lb/in.) axial compression and 245.2 N/cm (140 lb/in.) torsion. The overall cylinder geometry and design loading are representative of that expected on a high performance space tug vehicle. The relatively low design load level results in designs that use thin gage metals and fibrous-composite laminates. Fabrication and structural tests of small panels and components representative of many of the candidate designs served to demonstrate proposed fabrication techniques and to verify design and analysis methods. Three of the designs evaluated, honeycomb sandwich with aluminum faceskins, honeycomb sandwich with graphite/epoxy faceskins, and aluminum truss with fiber-glass meteoroid protection layers, were selected for further evaluation.

  2. Digital Micromirror Device (DMD-Based High-Cycle Torsional Fatigue Testing Micromachine for 1D Nanomaterials

    Directory of Open Access Journals (Sweden)

    Chenchen Jiang

    2016-03-01

    Full Text Available Fatigue behavior of nanomaterials could ultimately limit their applications in variable nano-devices and flexible nanoelectronics. However, very few existing nanoscale mechanical testing instruments were designed for dedicated fatigue experiments, especially for the challenging torsional cyclic loading. In this work, a novel high-cycle torsion straining micromachine, based on the digital micromirror device (DMD, has been developed for the torsional fatigue study on various one-dimensional (1D nanostructures, such as metallic and semiconductor nanowires. Due to the small footprint of the DMD chip itself and its cable-remote controlling mechanisms, it can be further used for the desired in situ testing under high-resolution optical or electron microscopes (e.g., scanning electron microscope (SEM, which allows real-time monitoring of the fatigue testing status and construction of useful structure-property relationships for the nanomaterials. We have then demonstrated its applications for testing nanowire samples with diameters about 100 nm and 500 nm, up to 1000 nm, and some of them experienced over hundreds of thousands of loading cycles before fatigue failure. Due to the commercial availability of the DMD and millions of micromirrors available on a single chip, this platform could offer a low-cost and high-throughput nanomechanical solution for the uncovered torsional fatigue behavior of various 1D nanostructures.

  3. Diagnostic evaluation of neck torsion test in objective examination in patients with vertigo and/or hearing impairment.

    Science.gov (United States)

    Niewiadomski, Piotr; Bielińska, Marzena; Pietkiewicz, Piotr; Olszewski, Jurek

    2017-10-30

    The aim of the study was to evaluate the neck torsion test in objective examinations of patients with vertigo and/or hearing loss. The study was conducted in 100 patients, including 54 women and 46 men aged 17-79 years, who were divided into two groups: I - 50 patients, including 30 women and 20 men aged 17-79 years (mean age 49.92 years) with dizziness and/or hearing impairments, and confirmed asymmetry of intracranial vessels, II - 50 patients - the control group, including 24 women and 26 men aged 20-71 years without dizziness and/or hearing disorders and without disturbance in the construction of intracranial vessels. For each patient, the following tests were carried out: subjective, objective otorhinolaryngological, Doppler ultrasound specifying the diameter of vertebral and carotid arteries and the velocity of blood flow in these vessels, audiological diagnostics, including the examination of latency of waves I, III, V of the auditory evoked potentials of the brain stem, otoneurological diagnostics with used the neck torsion test. It appears from the analysis of the material presented that the application of the neck torsion test in the Doppler ultrasound results in the fact that the difference in the mean systolic velocity of blood flow in vertebral artery is higher on the side opposite to the turning of the neck, and the increase in the average diastolic blood flow velocity in the vertebral artery on the side of the test being performed and its reduction on the opposite side in the study group, when compared to the control group. The value of the wave I, II, V latency in the ABR test during the neck torsion test is extended more in the study group than in the controls, on the side of the performed test. The performed neck torsion test in the VNG test increases the occurrence of both, square waves and nystagmus (much higher in the study group than in the controls). The application of the neck torsion test in the Doppler ultrasound, ABR and VNG test in

  4. Diagnostic evaluation of neck torsion test in objective examination in patients with vertigo and/or hearing-impairment.

    Science.gov (United States)

    Niewiadomski, Piotr; Bielińska, Marzena; Pietkiewicz, Piotr; Olszewski, Jurek

    2017-06-30

    The aim of the study was to evaluate the neck torsion test in objective examinations of patients with vertigo and/or hearing loss. The study was conducted in 100 patients, including 54 women and 46 men aged 17-79 years, who were divided into two groups: I - 50 patients, including 30 women and 20 men aged 17-79 years (mean age 49.92 years) with dizziness and/or hearing impairments, and confirmed asymmetry of intracranial vessels, II - 50 patients - control group, including 24 women and 26 men aged 20-71 years without dizziness and/or hearing disorders and without disturbance in the construction of intracranial vessels. For each patient, the following tests were carried out: subjective, objective otorhinolaryngological, Doppler ultrasound specifying diameter of vertebral and carotid arteries and the velocity of blood flow in these vessels, audiological diagnostics, including the examination of latency of waves I, III, V of the auditory evoked potentials of the brain stem, otoneurological diagnostics with used the neck torsion test. It appears from the analysis of the material presented that the application of the neck torsion test in the Doppler ultrasound results in the fact that the difference in the mean systolic velocity of blood flow in vertebral artery is higher on the side opposite to the turning of the neck, and the increase in the average diastolic blood flow velocity in the vertebral artery on the side of the test being performed and its reduction on the opposite side in the study group, when compared to the control group. The value of the wave I, II, V latency in the ABR test during the neck torsion test is extended more in the study group than in the controls, on the side of the performed test. The performed neck torsion test in the VNG test increases the occurrence of both, square waves and nystagmus (much higher in the study group than in the controls). Conclussion. The application of the neck torsion test in the Doppler ultrasound, ABR and VNG test in

  5. Transscrotal Near Infrared Spectroscopy as a Diagnostic Test for Testis Torsion in Pediatric Acute Scrotum: A Prospective Comparison to Gold Standard Diagnostic Test Study.

    Science.gov (United States)

    Schlomer, Bruce J; Keays, Melise A; Grimsby, Gwen M; Granberg, Candace F; DaJusta, Daniel G; Menon, Vani S; Ostrov, Lauren; Sheth, Kunj R; Hill, Martinez; Sanchez, Emma J; Harrison, Clanton B; Jacobs, Micah A; Huang, Rong; Burgu, Berk; Hennes, Halim; Baker, Linda A

    2017-09-01

    A rapid test for testicular torsion in children may obviate the delay for testicular ultrasound. In this study we assessed testicular tissue percent oxygen saturation (%StO2) measured by transscrotal near infrared spectroscopy as a diagnostic test for pediatric testicular torsion. This was a prospective comparison to a gold standard diagnostic test study that evaluated near infrared spectroscopy %StO2 readings to diagnose testicular torsion. The gold standard for torsion diagnosis was standard clinical care. From 2013 to 2015 males with acute scrotum for more than 1 month and who were less than 18 years old were recruited. Near infrared spectroscopy %StO2 readings were obtained for affected and unaffected testes. Near infrared spectroscopy Δ%StO2 was calculated as unaffected minus affected reading. The utility of near infrared spectroscopy Δ%StO2 to diagnose testis torsion was described with ROC curves. Of 154 eligible patients 121 had near infrared spectroscopy readings. Median near infrared spectroscopy Δ%StO2 in the 36 patients with torsion was 2.0 (IQR -4.2 to 9.8) vs -1.7 (IQR -8.7 to 2.0) in the 85 without torsion (p=0.004). AUC for near infrared spectroscopy as a diagnostic test was 0.66 (95% CI 0.55-0.78). Near infrared spectroscopy Δ%StO2 of 20 or greater had a positive predictive value of 100% and a sensitivity of 22.2%. Tanner stage 3-5 cases without scrotal edema or with pain for 12 hours or less had an AUC of 0.91 (95% CI 0.86-1.0) and 0.80 (95% CI 0.62-0.99), respectively. In all children near infrared spectroscopy readings had limited utility in diagnosing torsion. However, in Tanner 3-5 cases without scrotal edema or with pain 12 hours or less, near infrared spectroscopy discriminated well between torsion and nontorsion. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  6. Appendicular Torsion

    Directory of Open Access Journals (Sweden)

    Siddharth Pramod Dubhashi

    2016-01-01

    Full Text Available Torsion of the vermiform appendix is a rare condition detectable only at operation. It can be primary or secondary. This is a case report of 52-year-old female with 180° anti-clockwise rotation of the appendix. Torsion can further leads to strangulation and infarction of the organ. Appendicular torsion could be included in the differential diagnosis of pain in right iliac fossa.

  7. Solar system tests for realistic f(T) models with non-minimal torsion-matter coupling

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Rui-Hui; Zhai, Xiang-Hua; Li, Xin-Zhou [Shanghai Normal University, Shanghai United Center for Astrophysics (SUCA), Shanghai (China)

    2017-08-15

    In the previous paper, we have constructed two f(T) models with non-minimal torsion-matter coupling extension, which are successful in describing the evolution history of the Universe including the radiation-dominated era, the matter-dominated era, and the present accelerating expansion. Meantime, the significant advantage of these models is that they could avoid the cosmological constant problem of ΛCDM. However, the non-minimal coupling between matter and torsion will affect the tests of the Solar system. In this paper, we study the effects of the Solar system in these models, including the gravitation redshift, geodetic effect and perihelion precession. We find that Model I can pass all three of the Solar system tests. For Model II, the parameter is constrained by the uncertainties of the planets' estimated perihelion precessions. (orig.)

  8. Strength tests of thin-walled elliptic duralumin cylinders in pure bending and in combined pure bending and torsion

    Science.gov (United States)

    Lundquist, Eugene E; Stowell, Elbridge Z

    1942-01-01

    An analysis is presented of the results of tests made by the Massachusetts Institute of Technology and by the National Advisory Committee for Aeronautics on an investigation of the strength of thin-walled circular and elliptic cylinders in pure bending and in combined torsion and bending. In each of the loading conditions, the bending moments were applied in the plane of the major axis of the ellipse.

  9. Double torsion fracture mechanics testing of shales under chemically reactive conditions

    Science.gov (United States)

    Chen, X.; Callahan, O. A.; Holder, J. T.; Olson, J. E.; Eichhubl, P.

    2015-12-01

    Fracture properties of shales is vital for applications such as shale and tight gas development, and seal performance of carbon storage reservoirs. We analyze the fracture behavior from samples of Marcellus, Woodford, and Mancos shales using double-torsion (DT) load relaxation fracture tests. The DT test allows the determination of mode-I fracture toughness (KIC), subcritical crack growth index (SCI), and the stress-intensity factor vs crack velocity (K-V) curves. Samples are tested at ambient air and aqueous conditions with variable ionic concentrations of NaCl and CaCl2, and temperatures up to 70 to determine the effects of chemical/environmental conditions on fracture. Under ambient air condition, KIC determined from DT tests is 1.51±0.32, 0.85±0.25, 1.08±0.17 MPam1/2 for Marcellus, Woodford, and Mancos shales, respectively. Tests under water showed considerable change of KIC compared to ambient condition, with 10.6% increase for Marcellus, 36.5% decrease for Woodford, and 6.7% decrease for Mancos shales. SCI under ambient air condition is between 56 and 80 for the shales tested. The presence of water results in a significant reduction of the SCI from 70% to 85% compared to air condition. Tests under chemically reactive solutions are currently being performed with temperature control. K-V curves under ambient air conditions are linear with stable SCI throughout the load-relaxation period. However, tests conducted under water result in an initial cracking period with SCI values comparable to ambient air tests, which then gradually transition into stable but significantly lower SCI values of 10-20. The non-linear K-V curves reveal that crack propagation in shales is initially limited by the transport of chemical agents due to their low permeability. Only after the initial cracking do interactions at the crack tip lead to cracking controlled by faster stress corrosion reactions. The decrease of SCI in water indicates higher crack propagation velocity due to

  10. TESTICULAR TORSION:

    African Journals Online (AJOL)

    TESTICULAR TORSION: EXPERIENCE IN THE MIDDLE BELT OF NIGERIA. S.A. KURANGA AND G.A. RAHMAN. Department of Surgery, University of l/orin Teaching Hospital, Ilorin, Nigeria. Objective To determine the fate of the testis affected by testicular torsion (TT) in relation to the duration of the symptoms and to.

  11. Effect of Strain-Path Reversal on Microstructure Evolution and Cavitation During Hot Torsion Testing of Ti-6A1-4V (Preprint)

    National Research Council Canada - National Science Library

    Semiatin, S. L; Nicolaou, P. D

    2006-01-01

    Hot torsion testing comprising multiple twist reversals was used to establish the effect of strain-path changes on concurrent dynamic globularization and cavitation of Ti-6Al-4V with a colony-alpha...

  12. Torsional Shear Device for Testing the Dynamic Properties of Recycled Material

    Science.gov (United States)

    Gabryś, Katarzyna; Sas, Wojciech; Soból, Emil; Głuchowski, Andrzej

    2016-12-01

    From the viewpoint of environmental preservation and effective utilization of resources, it is beneficial and necessary to reuse wastes, for example, concrete, as the recycled aggregates for new materials. In this work, the dynamic behavior of such aggregates under low frequency torsional loading is studied. Results show that the properties of such artificial soils match with those reported in the literature for specific natural soils.

  13. Torsional Shear Device for Testing the Dynamic Properties of Recycled Material

    Directory of Open Access Journals (Sweden)

    Gabryś Katarzyna

    2016-12-01

    Full Text Available From the viewpoint of environmental preservation and effective utilization of resources, it is beneficial and necessary to reuse wastes, for example, concrete, as the recycled aggregates for new materials. In this work, the dynamic behavior of such aggregates under low frequency torsional loading is studied. Results show that the properties of such artificial soils match with those reported in the literature for specific natural soils.

  14. Discrete torsion

    International Nuclear Information System (INIS)

    Sharpe, Eric

    2003-01-01

    In this article we explain discrete torsion. Put simply, discrete torsion is the choice of orbifold group action on the B field. We derive the classification H 2 (Γ,U(1)), the twisted sector phases appearing in string loop partition functions, Douglas's description of discrete torsion for D-branes in terms of a projective representation of the orbifold group, and outline how the results of Vafa and Witten fit into this framework. In addition, we observe that additional degrees of freedom (known as shift orbifolds) appear in describing orbifold group actions on B fields, in addition to those classified by H 2 (Γ,U(1)), and explain how these degrees of freedom appear in terms of twisted sector contributions to partition functions and in terms of orbifold actions on D-brane worldvolumes. This paper represents a technically simplified version of prior papers by the author on discrete torsion. We repeat here technically simplified versions of results from those papers, and have included some new material

  15. Appendicular Torsion

    African Journals Online (AJOL)

    A‑2/103, Shivranjan Towers, Someshwarwadi, Pashan, Pune ‑ 411 008,. Maharashtra, India. E‑mail: spdubhashi@gmail.com. INTRODUCTION. Acute appendicitis presents with pain in right iliac fossa. Torsion of the vermiform appendix, though rare, also presents in a similar fashion, and it is detectable only at operation.[1].

  16. A computer program for plotting stress-strain data from compression, tension, and torsion tests of materials

    Science.gov (United States)

    Greenbaum, A.; Baker, D. J.; Davis, J. G., Jr.

    1974-01-01

    A computer program for plotting stress-strain curves obtained from compression and tension tests on rectangular (flat) specimens and circular-cross-section specimens (rods and tubes) and both stress-strain and torque-twist curves obtained from torsion tests on tubes is presented in detail. The program is written in FORTRAN 4 language for the Control Data 6000 series digital computer with the SCOPE 3.0 operating system and requires approximately 110000 octal locations of core storage. The program has the capability of plotting individual strain-gage outputs and/or the average output of several strain gages and the capability of computing the slope of a straight line which provides a least-squares fit to a specified section of the plotted curve. In addition, the program can compute the slope of the stress-strain curve at any point along the curve. The computer program input and output for three sample problems are presented.

  17. Testicular torsion

    DEFF Research Database (Denmark)

    Brasso, K; Andersen, L; Kay, L

    1993-01-01

    Thirty-five patients were examined 6-11 years after operation for torsion of the testis. Loss of testicular tissue was significantly associated with long preoperative duration of symptoms and with low postoperative sperm counts. The sex hormones were normal in the majority of patients but there w...... to the sperm count and concentration. Measurement of carnitine levels in seminal plasma, as a sign of vas deferens obstruction or dysfunction of epididymis, and of autoantibodies against spermatozoa revealed no significant findings....

  18. A Modified Edge Crack Torsion Test for Measurement of Mode III Fracture Toughness of Laminated Tape Composites

    Science.gov (United States)

    Czabaj, Michael W.; Davidson, Barry D.; Ratcliffe, James G.

    2016-01-01

    Modifications to the edge crack torsion (ECT) test are studied to improve the reliability of this test for measuring the mode-III fracture toughness, G (sub IIIc), of laminated tape fiber-reinforced polymeric (FRP) composites. First, the data reduction methods currently used in the ECT test are evaluated and deficiencies in their accuracy are discussed. An alternative data reduction technique, which uses a polynomial form to represent ECT specimen compliance solution, is evaluated and compared to FEA (finite element analysis) results. Second, seven batches of ECT specimens are tested, each batch containing specimens with a preimplanted midplane edge delamination and midplane plies with orientations of plus theta divided by minus theta, with theta ranging from 0 degrees to 90 degrees in 15-degree increments. Tests on these specimens show that intralaminar cracking occurs in specimens from all batches except for which theta = 15 degrees and 30 degrees. Tests on specimens of these two batches are shown to result in mode-III delamination growth at the intended ply interface. The findings from this study are encouraging steps towards the use of the ECT test as a standardized method for measuring G (sub IIIc), although further modification to the data reduction method is required to make it suitable for use as part of a standardized test method.

  19. DESIGN AND CONSTRUCTION OF A TORSIONAL FATIGUE TESTING MACHINE OPERATED BY INERTIAL LOADS

    Directory of Open Access Journals (Sweden)

    FABIO MARCELO PEÑA BUSTOS

    2012-01-01

    Full Text Available En este artículo se presenta el desarrollo de una máquina para pruebas de fatiga torsional en materiales metálicos. La máquina se considera de tipo I según la clasificación de Weibull debido a que la falla es producida por una carga de origen inercial. El principio de operación se basa en el movimiento alternante que produce la transmisión de una máquina lavadora. La carga inercial es producida por un volante ubicado en la parte superior de la máquina. A diferencia de muchas máquinas de fatiga que generan la alternancia de los esfuerzos mediante la reubicación o giro de la probeta respecto a cargas que son uniformes en el tiempo, en el diseño realizado se evidencia cómo las cargas inerciales debidas a las aceleraciones de los elementos mecánicos generan cargas de carácter alternante que llegan a ocasionar fallas por fatiga.

  20. Acute and intermittent testicular torsion: Analysis of presentation ...

    African Journals Online (AJOL)

    Background: Testicular torsion compromises the blood supply to the testes and may result in testicular loss or damage if not dealt with promptly. It can occur either as acute testicular torsion (ATT) or intermittent testicular torsion (ITT). This study examines the presentation, management, and outcome of adult testicular torsion.

  1. Constraining spacetime torsion with LAGEOS

    Science.gov (United States)

    March, Riccardo; Bellettini, Giovanni; Tauraso, Roberto; Dell'Agnello, Simone

    2011-11-01

    We compute the corrections to the orbital Lense-Thirring effect (or frame-dragging) in the presence of spacetime torsion. We analyze the motion of a test body in the gravitational field of a rotating axisymmetric massive body, using the parametrized framework of Mao, Tegmark, Guth and Cabi. In the cases of autoparallel and extremal trajectories, we derive the specific approximate expression of the corresponding system of ordinary differential equations, which are then solved with methods of Celestial Mechanics. We calculate the secular variations of the longitudes of the node and of the pericenter. We also show how the LAser GEOdynamics Satellites (LAGEOS) can be used to constrain torsion parameters. We report the experimental constraints obtained using both the nodes and perigee measurements of the orbital Lense-Thirring effect. This makes LAGEOS and Gravity Probe B complementary frame-dragging and torsion experiments, since they constrain three different combinations of torsion parameters.

  2. New test for determining fundamental transverse, longitudinal and torsional frequencies of concrete specimens

    Directory of Open Access Journals (Sweden)

    Gaidis, J. M.

    1986-06-01

    Full Text Available For twenty-five years The ASTM method used to determine reductions in concrete durability after freeze-thaw cycling has been C215-60. In this test the fundamental frequencies of a concrete specimen are compared. This test is time consuming, noisy and often inaccurate. In this paper a new method is proposed for measuring the fundamental frequencies of concrete to a single tap via a Fast Fourier Transform. The new test is faster, simpler and more accurate.

    El método usado por la ASTM desde hace 25 años para la determinación de la durabilidad del hormigón después de sufrir ciclos hielo/deshielo ha sido el C215-60. En este ensayo se comparan las frecuencias fundamentales de una probeta de hormigón. Este ensayo es ruidoso, lleva bastante tiempo y es bastante impreciso. En este trabajo se pone un nuevo método para medias frecuencias fundamentales en el hormigón por simple golpe mediante la TRANSFORMADA RÁPIDA de FOURIER. El nuevo método es más rápido, más simple y más preciso.

  3. Delamination Strength of WC-Co Thermal-Sprayed Coating Under Combined Stresses by Torsion-Tension Pin-Test Method

    Science.gov (United States)

    Kaneko, Kenji; Higaki, Keitaro

    2014-08-01

    In this report, the delamination strength of WC -Co thermal-sprayed coatings under combined torsion and tension is evaluated using a newly developed method, which is called the torsion -tension pin-test. First, the effects of both the pin diameter and the coating thickness on the apparent delamination strength were investigated experimentally. Second, the stress distributions around the interface edge between the pin and the coating were numerically obtained by using the finite element analysis program "MARC." It was confirmed that the fractured plane of the torsion pin coincides with the interfacial plane between the coating and the pin. The apparent delamination strength obtained experimentally decreased linearly with increasing pin diameter and increased with increasing coating thickness t, but it was stable at t of 400 μm or more. The shear delamination strength decreased with increasing tensile stress. Similar stress distributions were observed at the interface when delaminations occurred for rather thick coatings, independent of the pin diameter. The critical combination of the strength of shear stress fields ( Ks) with that of tensile stress fields ( Ka), i.e., the delamination criteria of the coating under combined shear and tensile loadings, was obtained for a WC-12Co thermal-sprayed coating. These combinations were found to be independent of pin diameter and coating thickness.

  4. Gallbladder torsion. Case report

    DEFF Research Database (Denmark)

    Brasso, K; Rasmussen, O V

    1991-01-01

    Gallbladder torsion is a rare surgical emergency occurring primarily in elderly women. The anatomical background is a variation in the attachment of the gallbladder to the inferior margin of the liver. Increasing life span will probably lead to an increasing number of cases, and gallbladder torsion...

  5. Maxwell field with torsion

    Energy Technology Data Exchange (ETDEWEB)

    Fresneda, R., E-mail: rodrigo.fresneda@ufabc.edu.br [Universidade Federal do ABC (UFABC), Santo Andre, SP (Brazil); Baldiotti, M.C.; Pereira, T.S., E-mail: baldiotti@uel.br, E-mail: tspereira@uel.br [Universidade Estadual de Londrina (UEL), Londrina, PR (Brazil). Departamento de Fisica

    2015-06-15

    We propose a gauge-invariant model of propagating torsion which couples to the Maxwell field and to charged particles. As a result, we have an Abelian gauge-invariant action leading to a theory with nonzero torsion consistent with available experimental data, which can be used to establish a lower bound for our new coupling parameter. (author)

  6. Postcesarean Splenic Torsion

    Directory of Open Access Journals (Sweden)

    Yu-Hui Huang

    2006-09-01

    Conclusion: Splenic torsion is a rare cause of acute abdominal pain during pregnancy or postpartum, and the symptoms vary depending on the degree of torsion. Early involvement of many complementary specialty services enabled early recognition of this rare entity and timely definitive treatment.

  7. Torsion pendulum revisited

    Energy Technology Data Exchange (ETDEWEB)

    Bassan, Massimo [Dipartimento di Fisica, Università di Roma Tor Vergata, and INFN, Sezione di Roma Tor Vergata, I-00133 Roma (Italy); De Marchi, Fabrizio, E-mail: fabrizio.demarchi@roma2.infn.it [Dipartimento di Fisica, Università di Roma Tor Vergata, and INFN, Sezione di Roma Tor Vergata, I-00133 Roma (Italy); Marconi, Lorenzo [Dipartimento di Fisica ed Astronomia, Università degli Studi di Firenze, and INFN, Sezione di Firenze (Italy); Pucacco, Giuseppe [Dipartimento di Fisica, Università di Roma Tor Vergata, and INFN, Sezione di Roma Tor Vergata, I-00133 Roma (Italy); Stanga, Ruggero [Dipartimento di Fisica ed Astronomia, Università degli Studi di Firenze, and INFN, Sezione di Firenze (Italy); Visco, Massimo [IAPS-INAF, and INFN, Sezione di Roma Tor Vergata, I-00133 Roma (Italy)

    2013-10-01

    We present an analysis of the motion of a simple torsion pendulum and we describe how, with straightforward extensions to the usual basic dynamical model, we succeed in explaining some unexpected features we found in our data, like the modulation of the torsion mode at a higher frequency and the frequency splitting of the swinging motion. Comparison with observed values yields estimates for the misalignment angles and other parameters of the model.

  8. Induced quantum torsion

    International Nuclear Information System (INIS)

    Denardo, G.; Spallucci, E.

    1985-07-01

    We study pregeometry in the framework of a Poincare gauge field theory. The Riemann-Cartan space-time is shown to be an ''effective geometry'' for this model in the low energy limit. By using Heat Kernel techniques we find the induced action for curvature and torsion. We obtain in this way the usual Einstein-Hilbert action plus an axial Maxwell term describing the propagation of a massless, axial vector torsion field. (author)

  9. Measuring fN force variations in the presence of constant nN forces: a torsion pendulum ground test of the LISA Pathfinder free-fall mode

    Science.gov (United States)

    Russano, G.; Cavalleri, A.; Cesarini, A.; Dolesi, R.; Ferroni, V.; Gibert, F.; Giusteri, R.; Hueller, M.; Liu, L.; Pivato, P.; Tu, H. B.; Vetrugno, D.; Vitale, S.; Weber, W. J.

    2018-02-01

    LISA Pathfinder is a differential accelerometer with the main goal being to demonstrate the near perfect free-fall of reference test masses, as is needed for an orbiting gravitational wave observatory, with a target sensitivity of 30 fm s‑2 Hz-1/2 at 1 mHz. Any lasting background differential acceleration between the two test masses must be actively compensated, and noise associated with the applied actuation force can be a dominant source of noise. To remove this actuation, and the associated force noise, a ‘free-fall’ actuation control scheme has been designed; actuation is limited to brief impulses, with both test masses in free-fall in the time between the impulses, allowing measurement of the remaining acceleration noise sources. In this work, we present an on-ground torsion pendulum testing campaign of this technique and associated data analysis algorithms at a level nearing the sub-femto-g/\\sqrtHz performance required for LISA Pathfinder.

  10. Twist buckling of veins under torsional loading.

    Science.gov (United States)

    Garcia, Justin R; Sanyal, Arnav; Fatemifar, Fatemeh; Mottahedi, Mohammad; Han, Hai-Chao

    2017-06-14

    Veins are often subjected to torsion and twisted veins can hinder and disrupt normal blood flow but their mechanical behavior under torsion is poorly understood. The objective of this study was to investigate the twist deformation and buckling behavior of veins under torsion. Twist buckling tests were performed on porcine internal jugular veins (IJVs) and human great saphenous veins (GSVs) at various axial stretch ratio and lumen pressure conditions to determine their critical buckling torques and critical buckling twist angles. The mechanical behavior under torsion was characterized using a two-fiber strain energy density function and the buckling behavior was then simulated using finite element analysis. Our results demonstrated that twist buckling occurred in all veins under excessive torque characterized by a sudden kink formation. The critical buckling torque increased significantly with increasing lumen pressure for both porcine IJV and human GSV. But lumen pressure and axial stretch had little effect on the critical twist angle. The human GSVs are stiffer than the porcine IJVs. Finite element simulations captured the buckling behavior for individual veins under simultaneous extension, inflation, and torsion with strong correlation between predicted critical buckling torques and experimental data (R 2 =0.96). We conclude that veins can buckle under torsion loading and the lumen pressure significantly affects the critical buckling torque. These results improve our understanding of vein twist behavior and help identify key factors associated in the formation of twisted veins. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Torsional resistance of retreatment instruments.

    Science.gov (United States)

    Lopes, Hélio P; Elias, Carlos N; Vedovello, Gislaine A F; Bueno, Carlos E S; Mangelli, Marcelo; Siqueira, José F

    2011-10-01

    This study compared the torsional resistance of two brands of rotary nickel-titanium (NiTi) instruments indicated for endodontic retreatment. Mtwo retreatment instruments #15 and #25 (VDW, Munich, Germany) and ProTaper Universal retreatment instruments D2 and D3 (Maillefer/Dentsply, Ballaigues, Switzerland) were subjected to a torsional assay in clockwise rotation. The two parameters evaluated were maximum torque and angular deflection at failure. Fractured instruments had their fractured surfaces and helical shafts examined by scanning electron microscopy. The results indicated that the angular deflection at fracture decreased in the following order: Mtwo retreatment file #15 > Mtwo retreatment file #25 > ProTaper Universal retreatment file D2 > ProTaper Universal retreatment file D3. As for the maximum torque values, the results revealed the following descending order: ProTaper Universal file D2 > Mtwo retreatment file #25 > ProTaper Universal file D3 > Mtwo retreatment file #15. Scanning electron microscopic analysis revealed that plastic deformation occurred along the helical shaft of the fractured instruments. Fractured surfaces were of the ductile type. The instruments tested showed different torsional behavior depending on the parameter evaluated. If one considers that high angular deflection values may serve as a safety factor, then the Mtwo retreatment instruments showed significantly better results. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  12. Volume elements and torsion

    Science.gov (United States)

    Mosna, Ricardo A.; Saa, Alberto

    2005-11-01

    We reexamine here the issue of consistency of minimal action formulation with the minimal coupling procedure (MCP) in spaces with torsion. In Riemann-Cartan spaces, it is known that a proper use of the MCP requires that the trace of the torsion tensor be a gradient, Tμ=∂μθ, and that the modified volume element τθ=eθ√g dx1∧⋯∧dxn be used in the action formulation of a physical model. We rederive this result here under considerably weaker assumptions, reinforcing some recent results about the inadequacy of propagating torsion theories of gravity to explain the available observational data. The results presented here also open the door to possible applications of the modified volume element in the geometric theory of crystalline defects.

  13. Higher Franz-Reidemeister torsion

    CERN Document Server

    Igusa, Kiyoshi

    2002-01-01

    The book is devoted to the theory of topological higher Franz-Reidemeister torsion in K-theory. The author defines the higher Franz-Reidemeister torsion based on Volodin's K-theory and Borel's regulator map. He describes its properties and generalizations and studies the relation between the higher Franz-Reidemeister torsion and other torsions used in K-theory: Whitehead torsion and Ray-Singer torsion. He also presents methods of computing higher Franz-Reidemeister torsion, illustrates them with numerous examples, and describes various applications of higher Franz-Reidemeister torsion, particularly for the study of homology of mapping class groups. Packed with up-to-date information, the book provides a unique research and reference tool for specialists working in algebraic topology and K-theory.

  14. Isolated Fallopian Tube Torsion

    Directory of Open Access Journals (Sweden)

    S. Kardakis

    2013-01-01

    Full Text Available Isolated torsion of the Fallopian tube is a rare gynecological cause of acute lower abdominal pain, and diagnosis is difficult. There are no pathognomonic symptoms; clinical, imaging, or laboratory findings. A preoperative ultrasound showing tubular adnexal masses of heterogeneous echogenicity with cystic component is often present. Diagnosis can rarely be made before operation, and laparoscopy is necessary to establish the diagnosis. Unfortunately, surgery often is performed too late for tube conservation. Isolated Fallopian tube torsion should be suspected in case of acute pelvic pain, and prompt intervention is necessary.

  15. Manual Detorsion of Testicular Torsion - A Primary Care Intervention ...

    African Journals Online (AJOL)

    Testicular torsion is one of the known acute urological emergencies that require prompt intervention. Salvage of the testis is only possible if derotation is performed within 6 hours of onset of symptoms. The objective of this paper is to report successful manual detorsion of the testes of patients with testicular torsion.

  16. CONSTRAINING SPACETIME TORSION WITH THE MOON, MERCURY AND LAGEOS

    Directory of Open Access Journals (Sweden)

    Riccardo March

    2013-12-01

    Full Text Available We consider an extension of Einstein General Relativity where, beside the Riemann curvature tensor, we suppose the presence of a torsion tensor. Using a parametrized theory based on symmetry arguments, we report on some results concerning the constraints that can be put on torsion parameters by studying the orbits of a test body in the solar system.

  17. Primary omental torsion in children: case report | Khalid | Pan ...

    African Journals Online (AJOL)

    Primary omental torsion in children: case report. Khattala Khalid, Tenorkorang Snr Somuah, Elmadi Aziz, Rami Mohamed, Bouabdallah Youssef. Abstract. Primary omental torsion is a rare cause of acute abdominal pain, we report a case of 10-year-old boy admitted with crampy abdominal pain, routine laboratory tests and ...

  18. Planar torsion spring

    Science.gov (United States)

    Ihrke, Chris A. (Inventor); Parsons, Adam H. (Inventor); Mehling, Joshua S. (Inventor); Griffith, Bryan Kristian (Inventor)

    2012-01-01

    A torsion spring comprises an inner mounting segment. An outer mounting segment is located concentrically around the inner mounting segment. A plurality of splines extends from the inner mounting segment to the outer mounting segment. At least a portion of each spline extends generally annularly around the inner mounting segment.

  19. Electrostatically suspended torsion pendulum

    Science.gov (United States)

    Willemenot, E.; Touboul, P.

    2000-01-01

    A torsion pendulum without a torsion wire has been designed and realized, in order to measure very weak forces. The arm of this torsion pendulum (5.40 g, 1.32×10-6 kg m2 of inertia) is electrostatically suspended. Its 6 degrees of freedom are controlled thanks to electrostatic forces, and capacitive position sensing with a noise spectral density between 10-10 and 10-13 m/√Hz . The torque noise spectral density is 1.3×10-14 Nm/√Hz around 0.05 Hz with a 1/√f increase at lower frequency, corresponding to 10-8 rad/s2/√Hz , and 2×10-10 ms-2/√Hz with a lever arm of 2 cm. The residual seismic noise limit the performances above 0.1 Hz. The free oscillating mode has a torsion stiffness of 5.14×10-8 Nm/rad and a Q of 217. This new instrument allows on ground experiments on very weak parasitic forces inside space accelerometers developed in ONERA, with a good representativeness. For example, it is possible to measure electrostatic stiffnesses with high resolution thanks to the low torque noise spectral density; the electrostatic damping phenomenon is also well seen as illustrated by the rather low Q. The instrument design and operation are described, the main performances are given, and the possibilities offered are discussed.

  20. Testicular Torsion (For Parents)

    Science.gov (United States)

    ... securing the testicles to the scrotum. If your son had a torsion that resulted in the loss of a testicle, it's important to let him know that he can still lead a normal life, just like anyone else. The loss of one testicle won't prevent a man from having normal sexual relations and is unlikely ...

  1. Gallbladder torsion. Case report

    DEFF Research Database (Denmark)

    Brasso, K; Rasmussen, O V

    1991-01-01

    Gallbladder torsion is a rare surgical emergency occurring primarily in elderly women. The anatomical background is a variation in the attachment of the gallbladder to the inferior margin of the liver. Increasing life span will probably lead to an increasing number of cases, and gallbladder torsi...

  2. Tumour, Torsion or Trauma?

    African Journals Online (AJOL)

    he had described a typical case in an 18 year old who later developed torsion of the contra-lateral testis and suffered ... he visited our hospital where an ultrasound scan was ordered, which was reported as showing an enlarged .... Mills S.E., Carter D., Reuter V.E., et al. Sternberg's diagnostic surgical pathology. 2004;4th.

  3. Torsion induces gravity

    International Nuclear Information System (INIS)

    Aros, Rodrigo; Contreras, Mauricio

    2006-01-01

    In this work the Poincare-Chern-Simons and anti-de Sitter-Chern-Simons gravities are studied. For both, a solution that can be cast as a black hole with manifest torsion is found. Those solutions resemble Schwarzschild and Schwarzschild-AdS solutions, respectively

  4. Triorchidism with Torsion

    African Journals Online (AJOL)

    are retractile and more mobility is at increased risk for torsion. An increased prevalence of carcinoma has also been reported.[1]. Case Report. A 72-year-old man presented with vague pain in the lower abdomen and scrotum. There was no history of trauma and he stated that the pain was severe in nature and had been ...

  5. Thermomechanical Testing and Microstructural Development of Class L Steel Wheel Alloy

    Science.gov (United States)

    1994-03-01

    Macrostructure, microstructure, and quantitative metallographic analysis is conducted on Association of American Railroads Class L wheel steel specimens tested in a Gleeble 1500 under combined mechanical compression and resistance heating to temperat...

  6. Torsional Performance of Wind Turbine Blades

    DEFF Research Database (Denmark)

    Branner, Kim; Berring, Peter; Berggreen, Christian

    2007-01-01

    The present work investigates how well different finite element modeling techniques can predict bending and torsion behavior of a wind turbine blade. Two shell models are investigated. One model has element offsets and the other has the elements at the mid-thickness surfaces of the model. The last...... two models investigated use a combination of shell and solid elements. The results from the numerical investigations are compared with measurements from testing of a section of a full-scale wind turbine blade. It is found that only the combined shell/solid models give reliable results in torsion. Both...

  7. Torsional Strengthening of RC Beams Using GFRP Composites

    Science.gov (United States)

    Patel, Paresh V.; Jariwala, Vishnu H.; Purohit, Sharadkumar P.

    2016-09-01

    Fiber reinforced polymer as an external reinforcement is used extensively for axial, flexural and shear strengthening in structural systems. The strengthening of members subjected to torsion is recently being explored. The loading mechanism of beams located at the perimeter of buildings which carry loads from slabs, joists and beams from one side of the member generates torsion that are transferred from the beams to the columns. In this work an experimental investigation on the improvement of the torsional resistance of reinforced concrete beams using Glass Fiber Reinforced Polymer (GFRP) is presented. Total 24 RC beams have been cast in this work. Ten beams of dimension 150 mm × 150 mm × 1300 mm are subjected to pure torsion while fourteen beams of 150 mm × 150 mm × 1700 mm are subjected to combined torsion and bending. Two beams in each category are designated as control specimen and remaining beams are strengthened by GFRP wrapping of different configurations. Pure torsion on specimens is applied using specially fabricated support mechanism and universal testing machine. For applying combined torsion and bending a loading frame and test set up are fabricated. Measurements of angle of twist at regular interval of torque, torsion at first crack, and ultimate torque, are obtained for all specimens. Results of different wrapping configurations are compared for control and strengthened beams to suggest effective GFRP wrapping configuration.

  8. Prediction of Torsional Strength for Very High Early Strength Geopolymer

    Directory of Open Access Journals (Sweden)

    Woraphot PRACHASAREE

    2017-11-01

    Full Text Available Very early high strength geopolymers are gaining acceptance as alternative repair materials for highways and other infrastructure. In this study, a very rapid geopolymer binder based on Metakaolin (MK and Parawood ash (PWA, developed by the authors, was experimentally tested and a prediction model for its torsional strength is proposed. The geopolymer samples were subjected to uniaxial compression, flexural beam, and torsion tests. The modulus of rupture and torsional strength in terms of compression strength were found to be well approximated by 0.7(f’c1/2 and 1/7(x2y (f’c1/2, respectively. Also an interaction relation to describe combined bending and torsion was developed in this study. In addition, the effects of aspect ratio (y/x were studied on both torsional strength and combined bending and torsion. It was found that an aspect ratio of y/x = 3 significantly reduced the torsional resistance, to about 50 % of the torsional strength of a square section.DOI: http://dx.doi.org/10.5755/j01.ms.23.4.17280

  9. Peculiar torsion dynamical response of spider dragline silk

    Science.gov (United States)

    Liu, Dabiao; Yu, Longteng; He, Yuming; Peng, Kai; Liu, Jie; Guan, Juan; Dunstan, D. J.

    2017-07-01

    The torsional properties of spider dragline silks from Nephila edulis and Nephila pilipes spiders are investigated by using a torsion pendulum technique. A permanent torsional deformation is observed after even small torsional strain. This behaviour is quite different from that of the other materials tested here, i.e., carbon fiber, thin metallic wires, Kevlar fiber, and human hair. The spider dragline thus displays a strong energy dissipation upon the initial excitation (around 75% for small strains and more for a larger strain), which correspondingly reduces the amplitude of subsequent oscillations around the new equilibrium position. The variation of torsional stiffness in relaxation dynamics of spider draglines for different excitations is also determined. The experimental result is interpreted in the light of the hierarchical structure of dragline silk.

  10. Torsional Ratcheting Actuating System

    Energy Technology Data Exchange (ETDEWEB)

    BARNES,STEPHEN MATTHEW; MILLER,SAMUEL L.; RODGERS,M. STEVEN; BITSIE,FERNANDO

    2000-01-24

    A new type of surface micromachined ratcheting actuation system has been developed at the Microelectronics Development Laboratory at Sandia National Laboratories. The actuator uses a torsional electrostatic comb drive that is coupled to an external ring gear through a ratcheting scheme. The actuator can be operated with a single square wave, has minimal rubbing surfaces, maximizes comb finger density, and can be used for open-loop position control. The prototypes function as intended with a minimum demonstrated operating voltage of 18V. The equations of motion are developed for the torsional electrostatic comb drive. The resonant frequency, voltage vs. displacement and force delivery characteristics are predicted and compared with the fabricated device's performance.

  11. Stability in quadratic torsion theories

    Energy Technology Data Exchange (ETDEWEB)

    Vasilev, Teodor Borislavov; Cembranos, Jose A.R.; Gigante Valcarcel, Jorge; Martin-Moruno, Prado [Universidad Complutense de Madrid, Departamento de Fisica Teorica I, Madrid (Spain)

    2017-11-15

    We revisit the definition and some of the characteristics of quadratic theories of gravity with torsion. We start from a Lagrangian density quadratic in the curvature and torsion tensors. By assuming that General Relativity should be recovered when the torsion vanishes and investigating the behaviour of the vector and pseudo-vector torsion fields in the weak-gravity regime, we present a set of necessary conditions for the stability of these theories. Moreover, we explicitly obtain the gravitational field equations using the Palatini variational principle with the metricity condition implemented via a Lagrange multiplier. (orig.)

  12. Stability in quadratic torsion theories

    Science.gov (United States)

    Vasilev, Teodor Borislavov; Cembranos, Jose A. R.; Valcarcel, Jorge Gigante; Martín-Moruno, Prado

    2017-11-01

    We revisit the definition and some of the characteristics of quadratic theories of gravity with torsion. We start from a Lagrangian density quadratic in the curvature and torsion tensors. By assuming that General Relativity should be recovered when the torsion vanishes and investigating the behaviour of the vector and pseudo-vector torsion fields in the weak-gravity regime, we present a set of necessary conditions for the stability of these theories. Moreover, we explicitly obtain the gravitational field equations using the Palatini variational principle with the metricity condition implemented via a Lagrange multiplier.

  13. Aerodynamic stability of long span suspension bridges with low torsional natural frequencies

    DEFF Research Database (Denmark)

    Andersen, Michael Styrk; Johansson, Jens; Brandt, Anders

    2016-01-01

    Classical flutter of suspended bridge decks can be avoided if the torsional frequencies are lower than the vertical. Wind tunnel tests of single boxes and twin box section models with torsional natural frequencies above and below the vertical frequency has been conducted. Flutter was avoided in all...... tests where the torsional frequency was lower than the vertical. But too low torsional stiffness caused large static displacements of the girder at medium–high wind speeds and steady state oscillations driven by a combination of torsional divergence and stalling behavior at the critical wind seed....... In order to design aerodynamically stable suspension bridges with low torsional natural frequencies it is suggested to increase the mass moment of inertia and provide adequate torsional stiffness by the main cables spacing....

  14. Apparatuses for prestressing rod-type specimens in torsion for in-situ passive fracture toughness testing in an extremely high-pressure environment of hydrogen

    Science.gov (United States)

    Wang, Jy-an [Oak Ridge, TN; Liu, Ken C [Oak Ridge, TN; Feng, Zhili [Knoxville, TN

    2012-05-15

    An in-situ specimen fixture particularly adapted for prestressing rod-type SNTT-type specimens comprising a tube and end cap wherein the specimen is secured at one end to the tube, and at the opposite end to the end cap. The end cap is rotatable relative to the tube, and may be fixedly secured for creating a torsional force prestressing the specimen enclosed within the tube.

  15. Pseudotopological quasilocal energy of torsion gravity

    Science.gov (United States)

    Ko, Sheng-Lan; Lin, Feng-Li; Ning, Bo

    2017-08-01

    Torsion gravity is a natural extension to Einstein gravity in the presence of fermion matter sources. In this paper we adopt Wald's covariant method of calculating the Noether charge to construct the quasilocal energy of the Einstein-Cartan-fermion system, and find that its explicit expression is formally independent of the coupling constant between the torsion and axial current. This seemingly topological nature is unexpected and is reminiscent of the quantum Hall effect and topological insulators. However, a coupling dependence does arise when evaluating it on shell, and thus the situation is pseudotopological. Based on the expression for the quasilocal energy, we evaluate it for a particular solution on the entanglement wedge and find agreement with the holographic relative entropy obtained before. This shows the equivalence of these two quantities in the Einstein-Cartan-fermion system. Moreover, the quasilocal energy in this case is not always positive definite, and thus it provides an example of a swampland in torsion gravity. Based on the covariant Noether charge, we also derive the nonzero fermion effect on the Komar angular momentum. The implications of our results for future tests of torsion gravity in gravitational-wave astronomy are also discussed.

  16. Torsion ratchet associated with mechanical hysteresis

    International Nuclear Information System (INIS)

    Han, S.; Wack, B.

    1987-01-01

    The experimental determination of behavior of material like metals, is often obtained with a tube shape sample. For the traction-compression and internal pressure test the direction of the solicitation principal axes is maintened constant. On the contrary the torsion test is a rotational solicitation and thus is accompagnied by secondary effects. For these reasons we conduct some cyclic torsion tests, with or without axial force, and attempt to measure as precisely as possible the axial deformation. The tests are run at a low strain rate and at room temperature so as to reduce as much as possible the influence of the viscosity phenomena and consequently to obtain results whose interpretation may be less complex. (orig./GL)

  17. Ultrafine grained Cu processed by compression with oscillatory torsion

    OpenAIRE

    K. Rodak

    2007-01-01

    Purpose: The aim of this work is a study of Cu microstructure after severe plastic deformation process by usingcompression with oscillatory torsion test.Design/methodology/approach: Cu samples were deformed at torsion frequency (f) changed from 0 Hz(compression) to 1.8 Hz under a constant torsion angle (α) ≈8° and compression speed (v)=0.1mm/s. Structuralinvestigations were conducted by using light microscopy (LM) and transmission electron microscopy (TEM).Findings: The structural analysis ma...

  18. Torsional Rigidity of Minimal Submanifolds

    DEFF Research Database (Denmark)

    Markvorsen, Steen; Palmer, Vicente

    2006-01-01

    We prove explicit upper bounds for the torsional rigidity of extrinsic domains of minimal submanifolds $P^m$ in ambient Riemannian manifolds $N^n$ with a pole $p$. The upper bounds are given in terms of the torsional rigidities of corresponding Schwarz symmetrizations of the domains in warped...

  19. Loads and performance data from a wind-tunnel test of model articulated helicopter rotors with 2 different blade torsional stiffnesses

    Science.gov (United States)

    Yeager, W. T., Jr.; Mantay, W. R.

    1983-01-01

    A passive means of tailoring helicopter rotor blades to improve performance and reduce loads was evaluated. The parameters investigated were blade torsional stiffness, blade section camber, and distance between blade structural elastic axis and blade tip aerodynamic center. This offset was accomplished by sweeping the tip. The investigation was conducted at advance ratios of 0.20, 0.30, and 0.40. Data are presented without analysis; however, cross referencing of performance data and harmonic loads data may be useful to the analyst for validating aeroelastic theories and design methodologies as well as for evaluating passive aeroelastic tailoring or rotor blade parameters.

  20. Ovarian torsion: Echographic discoveries

    International Nuclear Information System (INIS)

    Triana R, Gustavo; Navas O, Claudia

    1994-01-01

    Patient of 31 years who consulted to the even service of urgencies to present of two hours of evolution intense pain in flank and region lumbar left, associated to vomit, present square similar 5 previous days to the entrance in the right side. Go Po, plans with DIU FUR, 8 previous days to the square. It is practiced Tran abdominal pelvic echography that shows left ovary of 6 x 5 x 3 cms, with multiple follicular images, of thick walls, with I liquidate free abdominal, highly suggestive of ovarian torsion although the patient didn't present square of sharp abdomen. It decides to suspend analgesic and to value it, presented sharp abdominal pain, reason why laparotomy was practiced, finding mass of 6 x 6 cms. of necrotic aspect, corresponding to the left ovary, which presented three turns on their axis. It is taken finish left salpingooferectomy

  1. Re-torsion of the ovaries

    DEFF Research Database (Denmark)

    Hyttel, Trine E W; Bak, Geske S; Larsen, Solveig B

    2015-01-01

    The increasing use of de-torsion of the ovaries may result in re-torsion. This review addresses risk of re-torsion and describes preventive strategies to avoid re-torsion in pre-menarcheal girls, and fertile and pregnant women. We clinically reviewed PubMed, Embase, Trip and Cochrane databases...

  2. Spin and torsion in gravitation

    CERN Document Server

    De Sabbata, Venzo

    1994-01-01

    This book gives an exposition of both the old and new results of spin and torsion effects on gravitational interactions with implications for particle physics, cosmology etc. Physical aspects are stressed and measurable effects in relation to other areas of physics are discussed.Among the topics discussed are: alternative ways of unifying gravity with electroweak and strong interactions by an energy dependent spin torsion coupling constant; the idea that all interactions can be understood as originating from spin curvature coupling; the possibility of cosmological models with torsion providing

  3. Numerical Analysis of Stress and Strain in Specimens with Rectangular Cross-Section Subjected to Torsion and Bending with Torsion

    Directory of Open Access Journals (Sweden)

    Faszynka Sebastian

    2016-03-01

    Full Text Available The paper presents an analysis of the state of stress and crack tip opening displacement (strain in specimens with rectangular cross-section subjected to torsion and combined bending with torsion. The specimens were made of the EN AW-2017A aluminium alloy. The specimens had an external unilateral notch, which was 2 mm deep and its radius was 22.5 mm. The tests were performed at constant moment amplitude MT = MBT = 15.84 N·m and under stress ratio R = −1. The exemplary results of numerical computations being obtained by using the FRANC3D software were shown in the form of stress and crack tip opening displacement (CTOD maps. The paper presents the differences of fatigue cracks growth under torsion and bending with torsion being derived by using the FRANC3D software.

  4. Anthropometric study of angle of femoral torsion in Maharashtrian population

    Directory of Open Access Journals (Sweden)

    Anil Kumar Dwivedi

    2016-01-01

    Full Text Available Introduction: Angle of femoral torsion is a normal torsion or twist present in femur that plays an important role in stability and function of the hip joint. The angle of femoral torsion can be defined as the angle formed by femoral condyle′s plane (bicondylar plane and a plane passing through center of neck and femoral head. Abnormal angle of femoral torsion has been implicated in the etiology of hip osteoarthrosis and developmental dysplasia of hip joint. Materials and Methods: This study was carried out on unpaired 280, adult human femora devoid of any gross pathology, 139 male (65 right and 74 left, and 141 female (71 right and 70 left from bone banks of three medical colleges of Maharashtra. The gender of each specimen was determined by the established practice. Femora were evaluated by Kingsley Olmsted method, and data were tabulated and statistically analyzed. Results: The average angle of femoral torsion 13.39° and 11.23° on the right and left side respectively in male, 16.21° and 13.23° on the right and left side, respectively, in female. Statistical analysis using Student′s "t"-test revealed significant difference (P < 0.05, greater angle of femoral torsion in female and on the right side. Conclusion: Knowledge of angle of femoral torsion is becoming significant nowadays with an increase in demand for total hip replacement, as the angle of femoral torsion is crucial to attain a normal activity of the replaced joint.

  5. ESTIMATING TORSION OF DIGITAL CURVES USING 3D IMAGE ANALYSIS

    Directory of Open Access Journals (Sweden)

    Christoph Blankenburg

    2016-04-01

    Full Text Available Curvature and torsion of three-dimensional curves are important quantities in fields like material science or biomedical engineering. Torsion has an exact definition in the continuous domain. However, in the discrete case most of the existing torsion evaluation methods lead to inaccurate values, especially for low resolution data. In this contribution we use the discrete points of space curves to determine the Fourier series coefficients which allow for representing the underlying continuous curve with Cesàro’s mean. This representation of the curve suits for the estimation of curvature and torsion values with their classical continuous definition. In comparison with the literature, one major advantage of this approach is that no a priori knowledge about the shape of the cyclic curve parts approximating the discrete curves is required. Synthetic data, i.e. curves with known curvature and torsion, are used to quantify the inherent algorithm accuracy for torsion and curvature estimation. The algorithm is also tested on tomographic data of fiber structures and open foams, where discrete curves are extracted from the pore spaces.

  6. Residual torsional properties of composite shafts subjected to impact loadings

    International Nuclear Information System (INIS)

    Sevkat, Ercan; Tumer, Hikmet

    2013-01-01

    Highlights: • Impact loading reduces the torsional strength of composite shaft. • Impact energy level determines the severity of torsional strength reduction. • Hybrid composite shafts can be manufactured by mixing two types of filament. • Maximum torque capacity of shafts can be estimated using finite element method. - Abstract: This paper presents an experimental and numerical study to investigate residual torsional properties of composite shafts subjected to impact loadings. E-glass/epoxy, carbon/epoxy and E-glass–carbon/epoxy hybrid composite shafts were manufactured by filament winding method. Composite shafts were impacted at 5, 10, 20 and 40 J energy levels. Force–time and energy–time histories of impact tests were recorded. One composite shaft with no impact, and four composite shafts with impact damage, five in total, were tested under torsion. Torque-twisting angle relations for each test were obtained. Reduction at maximum torque and maximum twisting angle induced by impact loadings were calculated. While 5 J impact did not cause significant reduction at maximum torque and maximum twisting angle, remaining impact loadings caused 34–67% reduction at maximum torque, and 30–61% reduction at maximum twisting angle. Reductions increased with increasing energy levels and varied depending on the material of composite shafts. The 3-D finite element (FE) software, Abaqus, incorporated with an elastic orthotropic model, was then used to simulate the torsion tests. Good agreement between experimental and numerical results was achieved

  7. Torsional Phacoemulsification and Tip Selection

    Directory of Open Access Journals (Sweden)

    Fırat Helvacıoğlu

    2014-10-01

    Full Text Available One of the recent advances in cataract surgery is torsional phacoemulsification. It was developed to increase the efficacy of ultrasonic emulsification. In torsional phacoemulsification, the torsional movement of the tip is translated to side-to-side cutting action with the aid of bent phaco tips. Lens material is cut in both directions, rather than only during a forward stroke. The efficiency of this technique is further enhanced by an improvement in followability provided by the inherent non-repulsive nature of the side-to-side motion. Tip selection is very important for the efficiency of torsional phacoemulsification. Theoretically, there are 2 ways to enhance the cutting efficiency of the tip. First is the stroke length; the 22-degree bent 30-degree Kelman mini-flared tip cuts longer than the 12-degree bent 30-degree mini-flared Kelman tip. Second is the angulation or bevel; the higher the degree (45 degrees, the better cutting efficiency. Retrospective analyses of the previously published clinical studies clearly demonstrated that the efficacy of the torsional phacoemulsification has positive correlation with both the aperture angles and neck angles of the tips. (Turk J Ophthalmol 2014; 44: 392-5

  8. Crack path in aeronautical titanium alloy under ultrasonic torsion loading

    Directory of Open Access Journals (Sweden)

    A. Nikitin

    2016-01-01

    Full Text Available This paper discusses features of fatigue crack initiation and growth in aeronautical VT3-1 titanium alloy under pure torsion loading in gigacycle regime. Two materials: extruded and forged VT3-1 titanium alloys were studied. Torsion fatigue tests were performed up to fatigue life of 109 cycles. The results of the torsion tests were compared with previously obtained results under fully reversed axial loading on the same alloys. It has been shown that independently on production process as surface as well subsurface crack initiation may appear under ultrasonic torsion loading despite the maximum stress amplitude located at the specimen surface. In the case of surface crack initiation, a scenario of crack initiation and growth is similar to HCF regime except an additional possibility for internal crack branching. In the case of subsurface crack, the initiation site is located below the specimen surface (about 200 μm and is not clearly related to any material flaw. Internal crack initiation is produced by shear stress in maximum shear plane and early crack growth is in Mode II. Crack branching is limited in the case of internal crack initiation compared to surface one. A typical ‘fish-eye’ crack can be observed at the torsion fracture surface, but mechanism of crack initiation seems not to be the same than under axial fatigue loading.

  9. Dirac operators and Killing spinors with torsion

    International Nuclear Information System (INIS)

    Becker-Bender, Julia

    2012-01-01

    On a Riemannian spin manifold with parallel skew torsion, we use the twistor operator to obtain an eigenvalue estimate for the Dirac operator with torsion. We consider the equality case in dimensions four and six. In odd dimensions we describe Sasaki manifolds on which equality in the estimate is realized by Killing spinors with torsion. In dimension five we characterize all Killing spinors with torsion and obtain certain naturally reductive spaces as exceptional cases.

  10. Torsional superelasticity of NiTi archwires.

    Science.gov (United States)

    Bolender, Yves; Vernière, Anne; Rapin, Christophe; Filleul, Marie-Pierryle

    2010-11-01

    To reproduce and compare the intraoral torsional behavior of 10 commonly used preformed upper NiTi 0.017 x 0.025 archwires in 0.018-slot brackets at 20 degrees C, 35 degrees C, and 55 degrees C. Ten upper preformed NiTi archwires were compared to a multibraided stainless steel wire. An original testing bench was used to reproduce palatal root torque applied onto an upper central incisor with a maximum value of 1540 g x mm. Ten samples of each wire type were tested at 20 degrees C, 35 degrees C, and 55 degrees C each. Loading and unloading at 20 degrees C revealed three categories of wires: a group of four NiTi wires of relative stiffness bereft of any superelasticity, a group of six NiTi wires displaying some horizontal plateau, and finally the stainless steel wire of lesser stiffness. Testing at the average oral temperature of 35 degrees C produced the same three categories of wires, with only 2 of 10 NiTi wires displaying a superelastic effect (Copper NiTi 35 degrees C and 40 degrees C). None of the NiTi wires was superelastic at 55 degrees C. Moments increased with temperature as the martensite was replaced by the more rigid austenite. This study showed that most NiTi wires did not exhibit in torsion the superelastic effect traditionally described in bending. The combination of straight-wire prescriptions and rectangular superelastic NiTi archwires did not provide optimal constant moments necessary to gain third-order control of tooth movement early in treatment. A braided stainless steel rectangular archwire displayed better torsional behavior at 35 degrees C than most NiTi archwires of the same dimensions.

  11. PROPOSAL OF THE DYNAMIC ANALYSIS TECHNIQUE CONSIDERING INTERACTION BETWEEN BENDING AND TORSION AND NONLINEAR TORSION

    Science.gov (United States)

    Otsuka, Hisanori; Hattori, Masahiro

    When the structures, for example arch bridges are subjected bending moments and torsional moments, the strength and rigidity of the members decline compared to those of pure bending or torsion load condition. However, any analysis soft don't consider interrelation between bending and torsion ,and effects of torsional moments have not been considered severely in seismic design. In this study, the authors proposed analysis technique considering interaction between bending and torsion to estimate torsional moments severely, and formulized the analysis tools for this technique. These are interaction curve, skeleton for combined load, hysteresis for torsion. Moreover, the authors analyzed a RC arch bridge using this method, and inspected the validity of comparing the results obtained equivalent linear analysis about torsion and nonlinear torsional analysis not considering the interaction between bending and torsion.

  12. The static characteristics of a torsionally flexible metal coupling

    Directory of Open Access Journals (Sweden)

    Krzysztof FILIPOWICZ

    2008-01-01

    Full Text Available The paper presents a description of test stands and the methodology ofdetermining the static characteristics of a metal coupling of high torsional flexibility. In addition, the paper presents preliminary tests results which enable to determine the above characteristics.

  13. Torsional Stiffness Comparison of Different Tube Cross-Sections of a Formula SAE Car Space Frame

    Directory of Open Access Journals (Sweden)

    Hao Liu Cong

    2018-01-01

    Full Text Available Since torsional loading and the accompanying deformation of the frame and suspension parts can affect the handling and performance of the car, torsional stiffness is generally thought to be a primary determinant of frame performance for a FSAE car. According to the FSAE Rules, different tube cross-sections are available for some members of a space frame. By finite element simulation, this research compared different tube shapes and thicknesses. Compared with 1.6 mm thickness round tube, square tube with the same wall thickness can improve the torsional stiffness by 23% in test Mode I, and 65% in test Mode II. The 1.2mm thickness square tube also can improve the torsional stiffness by 6% and 39% in test Mode I and Mode II. From these comparisons, it can be found the usage of square tube can improve the frame torsional stiffness efficiently.

  14. Painless Ovarian Torsion Mimicking a Uterine Myoma

    Directory of Open Access Journals (Sweden)

    Cheng-Kuo Lin

    2006-12-01

    Conclusion: Ovarian torsion is a significant cause of acute lower abdominal pain in women and is a gynecologic surgical emergency. Nevertheless, surgical strategies are usually impeded because of ambiguous warning signs. Clinicians may be misled by certain conditions such as silent ovarian torsion. Although there may be no specific indication, the diagnosis of ovarian torsion should be considered on finding a pelvic mass.

  15. The odd side of torsion geometry

    DEFF Research Database (Denmark)

    Conti, Diego; Madsen, Thomas Bruun

    2012-01-01

    We introduce and study a notion of `Sasaki with torsion structure' (ST) as an odd-dimensional analogue of Kähler with torsion geometry (KT). These are normal almost contact metric manifolds that admit a unique compatible connection with 3-form torsion. Any odd-dimensional compact Lie group is sho...

  16. Dynamic Bending and Torsion Stiffness Derivation from Modal Curvatures and Torsion Rates

    Science.gov (United States)

    MAECK, J.; DE ROECK, G.

    1999-08-01

    In order to maintain the reliability of civil engineering structures, considerable effort is currently spent on developing a non-destructive vibration testing method for monitoring the structural integrity of constructions. The technique must be able to observe damage, secondly to localize the damage; and finally to give an idea of the severity of the damage. Within the framework of relating changes of measured modal parameters to changes in the integrity of the structure, it is important to be able to determine the dynamic stiffness in each section of the structure from measured modal characteristics.A damaged structure results in a dynamic stiffness reduction of the cracked sections. The dynamic stiffnesses provide directly an indication of the extension of the cracked zones in the structure. The dynamic stiffness reduction can also be associated with a degree of cracking in a particular zone.In an experimental programme, a concrete beam of 6 m length is subjected to an increasing static load to produce cracks. After each static perload, the beam is tested dynamically in a free-free set-up. The change in modal parameters is then related to damage in the beam.The technique that will be presented in the paper to predict the damage location and intensity is a direct stiffness derivation from measured modal displacement derivatives. Using the bending modes, the dynamic bending stiffness can be derived from modal curvatures. Using the torsional modes, the dynamic torsion stiffness can be derived from modal torsion rates.

  17. Optical fiber accelerometer based on MEMS torsional micromirror

    Science.gov (United States)

    Zeng, Fanlin; Zhong, Shaolong; Xu, Jing; Wu, Yaming

    2008-03-01

    A novel structure of optical fiber accelerometer based on MEMS torsional micro-mirror is introduced, including MEMS torsional micro-mirror and optical signal detection. The micro-mirror is a non-symmetric one, which means that the torsional bar supporting the micro-mirror is not located in the axis where the center of the micro-mirror locates. The optical signal detection is composed of PIN diode and dual fiber collimator, which is very sensitive to the coupling angle between the input fiber and output fiber. The detection principle is that acceleration is first transformed into torsional angle of the micro-mirror, then, optical insertion loss of the dual fiber collimator caused by the angle can be received by PIN. So under the flow of acceleration to torsional angle to optical signal attenuation to optical power detection, the acceleration is detected. The theory about sensing and optical signal detect of the device are discussed in this paper. The sensitive structure parameters and performance parameters are calculated by MATLAB. To simulate the static and modal analysis, the finite element analysis, ANSYS, is employed. Based on the above calculation, several optimization methods and the final structure parameters are given. The micro-mirror is completed by using silicon-glass bonding and deep reactive ion etching (DRIE). In the experiment, the acceleration is simulated by electrostatic force and the test results show that the static acceleration detection agrees with the theory analysis very well.

  18. Elevated temperature axial and torsional fatigue behavior of Haynes 188

    Science.gov (United States)

    Bonacuse, Peter J.; Kalluri, Sreeramesh

    1995-01-01

    The results are reported for high-temperature axial and torsional low-cycle fatigue experiments performed at 760 C in air on thin-walled tubular specimens of Haynes 188, a wrought cobalt-based superalloy. Data are also presented for mean coefficient of thermal expansion, elastic modulus, and shear modulus at various temperatures from room to 1000 C, and monotonic and cyclic stress-strain curves in tension and in shear at 760 C. This data set is used to evaluate several multiaxial fatigue life models (most were originally developed for room temperature multiaxial life prediction) including von Mises equivalent strain range (ASME Boiler and Pressure Code), Manson-Halford, modified multiaxiality factor (proposed in this paper), modified Smith-Watson-Topper, and Fatemi-Socie-Kurath. At von Mises equivalent strain ranges (the torsional strain range divided by the square root of 3, taking the Poisson's ratio to be 0.5), torsionally strained specimens lasted, on average, factors of 2 to 3 times longer than axially strained specimens. The modified multiaxiality factor approach shows promise as a useful method of estimating torsional fatigue life from axial fatigue data at high temperatures. Several difficulties arose with the specimen geometry and extensometry used in these experiments. Cracking at extensometer probe indentations was a problem at smaller strain ranges. Also, as the largest axial and torsional strain range fatigue tests neared completion, a small amount of specimen buckling was observed.

  19. Some Investigations of the General Instability of Stiffened Metal Cylinders VII : Stiffened Metal Cylinders Subjected to Combined Bending and Torsion

    Science.gov (United States)

    1943-01-01

    This report summarizes the work that has been carried on in the experimental investigation of the problem of the general instability of stiffened metal cylinders subjected to combined bending and torsion at the C.I.T. This part of the investigation included tests on 26 sheet-covered specimens. An interaction curve for the case of combined bending and torsion is presented. The results of tests of 17 specimens subjected to pure torsion are also given.

  20. Effects of axial compression and rotation angle on torsional mechanical properties of bovine caudal discs.

    Science.gov (United States)

    Bezci, Semih E; Klineberg, Eric O; O'Connell, Grace D

    2018-01-01

    The intervertebral disc is a complex joint that acts to support and transfer large multidirectional loads, including combinations of compression, tension, bending, and torsion. Direct comparison of disc torsion mechanics across studies has been difficult, due to differences in loading protocols. In particular, the lack of information on the combined effect of multiple parameters, including axial compressive preload and rotation angle, makes it difficult to discern whether disc torsion mechanics are sensitive to the variables used in the test protocol. Thus, the objective of this study was to evaluate compression-torsion mechanical behavior of healthy discs under a wide range of rotation angles. Bovine caudal discs were tested under a range of compressive preloads (150, 300, 600, and 900N) and rotation angles (± 1, 2, 3, 4, or 5°) applied at a rate of 0.5°/s. Torque-rotation data were used to characterize shape changes in the hysteresis loop and to calculate disc torsion mechanics. Torsional mechanical properties were described using multivariate regression models. The rate of change in torsional mechanical properties with compression depended on the maximum rotation angle applied, indicating a strong interaction between compressive stress and maximum rotation angle. The regression models reported here can be used to predict disc torsion mechanics under axial compression for a given disc geometry, compressive preload, and rotation angle. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. TORSION OF THE VERMIFORM APPENDIX: A CASE REPORT

    Directory of Open Access Journals (Sweden)

    Dr. Imtiaz Wani

    2009-07-01

    Full Text Available Torsion of the vermiform appendix is a rare condition with few cases reported in the literature. Various factors predispose to torsion. Various factors predispose to torsion. We report a case of primary torsion of the vermiform appendix. The clinical presentation was indistinguishable from acute appendicitis and the diagnosis was made at operation. Appendix was preileal in position and the direction of torsion was anticlockwise. There was intrinsic torsion with no obvious factor for torsion identified. Appendectomy was performed.

  2. Timoshenko-Wagner-Kappus Torsion Bending Theory and Wind ...

    Indian Academy of Sciences (India)

    Timoshenko-Wagner-Kappus Torsion Bending. Theory and Wind Tunnel Balance Design. S P Govinda Raju and K R Y Simha. S P Govinda Raju is a. Professor at the. Aero- space Engineering. Department, Indian. Institute of Science,. Bangalore. His interests are fluid mechanics, aircraft design, testing and analysis.

  3. Triorchidism with Torsion | Kumar | Annals of Medical and Health ...

    African Journals Online (AJOL)

    Polyorchidism is a rare anomaly; triorchidism is the commonest type and is frequently associated with cryptorchidism, inguinal hernia, and testicular torsion. It is also reported as an increased risk of testicular malignancy. We report a case of 72.year.old man with left supernumerary testes in the left hemiscrotum.

  4. Numerical simulation of lateral-torsional buckling of coped girders

    NARCIS (Netherlands)

    Maljaars, J.; Steenbergen, H.M.G.M.; Stark, J.W.B.; Abspoel, R.

    2002-01-01

    The lateral torsional buckling resistance of girders depends on the support conditions. In floor structures for buildings, coped girders are often used. A numerical model was developed to research the influence of copes on lateral buckling resistance. The model is successfully validated with tests.

  5. Intermittent Testicular Torsion

    African Journals Online (AJOL)

    2017-12-05

    , presence of abnormal testicular lie in otherwise normal testes, absence of urinary symptoms, and negative urine cultures. This diagnosis was confirmed by resolution of symptoms following bilateral orchidopexy. All patients ...

  6. Torsions of 3-dimensional manifolds

    CERN Document Server

    Wurzbacher, T

    2002-01-01

    From the reviews: "This is an excellent exposition about abelian Reidemeister torsions for three-manifolds." ―Zentralblatt Math "This monograph contains a wealth of information many topologists will find very handy. …Many of the new points of view pioneered by Turaev are gradually becoming mainstream and are spreading beyond the pure topology world. This monograph is a timely and very useful addition to the scientific literature." ―Mathematical Reviews

  7. Moduli space of torsional manifolds

    International Nuclear Information System (INIS)

    Becker, Melanie; Tseng, L.-S.; Yau, S.-T.

    2007-01-01

    We characterize the geometric moduli of non-Kaehler manifolds with torsion. Heterotic supersymmetric flux compactifications require that the six-dimensional internal manifold be balanced, the gauge bundle be Hermitian Yang-Mills, and also the anomaly cancellation be satisfied. We perform the linearized variation of these constraints to derive the defining equations for the local moduli. We explicitly determine the metric deformations of the smooth flux solution corresponding to a torus bundle over K3

  8. Newton-Cartan gravity and torsion

    Science.gov (United States)

    Bergshoeff, Eric; Chatzistavrakidis, Athanasios; Romano, Luca; Rosseel, Jan

    2017-10-01

    We compare the gauging of the Bargmann algebra, for the case of arbitrary torsion, with the result that one obtains from a null-reduction of General Relativity. Whereas the two procedures lead to the same result for Newton-Cartan geometry with arbitrary torsion, the null-reduction of the Einstein equations necessarily leads to Newton-Cartan gravity with zero torsion. We show, for three space-time dimensions, how Newton-Cartan gravity with arbitrary torsion can be obtained by starting from a Schrödinger field theory with dynamical exponent z = 2 for a complex compensating scalar and next coupling this field theory to a z = 2 Schrödinger geometry with arbitrary torsion. The latter theory can be obtained from either a gauging of the Schrödinger algebra, for arbitrary torsion, or from a null-reduction of conformal gravity.

  9. Using torsion to manipulate spin currents

    Science.gov (United States)

    Fumeron, Sébastien; Berche, Bertrand; Medina, Ernesto; Santos, Fernando A. N.; Moraes, Fernando

    2017-02-01

    We address the problem of quantum particles moving on a manifold characterised by the presence of torsion along a preferential axis. In fact, such a torsion may be taylored by the presence of a single screw dislocation, whose Burgers vector measures the torsion amplitude. The problem, first treated in the relativistic limit describing fermions that couple minimally to torsion, is then analysed in the Pauli limit. We show that torsion induces a geometric potential and also that it couples generically to the phase of the wave function, giving rise to the possibility of using torsion to manipulate spin currents in the case of spinor wave functions. These results emerge as an alternative strategy for using screw dislocations in the design of spintronic-based devices.

  10. Role of P-31 MR spectroscopy in assessing testicular torsion: Rat model

    International Nuclear Information System (INIS)

    Tzika, A.A.; Vignerson, D.; Hricak, H.; Kogan, B.A.; Moseley, M.E.; James, T.L.

    1988-01-01

    In six Copenhagen rats, serial P-31 MR spectroscopy spectra (at 2 T, General Electric CSI-II) were obtained from both exposed testes before and at 30-minute intervals after unilateral torsion and detorsion. The phosphomonoester-inorganic phosphate (PME/Pi) peak area ratio calculated from the spectra were used as an indicator of the cellular metabolic state. In normal testis, P-31 MR spectroscopy spectra manifested prominent PME and adenosine triphosphate (ATP) peaks. Testicular torsion caused dramatic reduction of ATP to nondetectable levels and a significant decrease in the PME/Pi ratio during the 1-hour period following torsion (control, PME/Pi = 3.21 +- 0.52; 30-minute torsion, PME/Pi = 1.14 +- 0.24; 1-hour torsion, PME/Pi = 1.21 +- 0.26, mean +- SD; P < .0005, Student t test). The contralateral testis not subjected to torsion showed no significant spectral changes. One hour after detorsion, PME/Pi returned to normal within 3 hours. When torsion was maintained longer than 1 hour and PME/Pi fell below 1.0, the testes failed to return to normal after detorsion

  11. Quantum General Relativity, Torsion and Uncertainty Relations

    Science.gov (United States)

    de Sabbata, V.; Sivaram, C.; Borzeszkowski, H.-H. V.; Treder, H.-J.

    It is shown that in gravitational theories with torsion one is led to commutation rules corresponding to Landau-Peierls type uncertainty relations.Translated AbstractQuantisierte allgemeine Relativitätstheorie, Torsion und UnschärferelationenEs wird gezeigt, daß man in Gravitationstheorien mit Torsion zu Vertauschungsregeln geführt wird, die Landau-Peierls-artigen Unschärferelationen entsprechen.

  12. Tibial Torsion Among Filipinos: A Cadaveric Study

    Directory of Open Access Journals (Sweden)

    Villamin CAC

    2012-07-01

    Full Text Available Tibial torsion, the twisting of the tibia about its long axis, can affect rotational positioning in total knee replacement. This angle varies depending on the ethnicity of the subject. There are no published studies to date to determine the tibial torsion among Filipinos. In this study, 28 cadaveric limbs were examined. Our results show that the average tibial torsion among adult Filipinos is 28.9°.

  13. Dirac operators and Killing spinors with torsion; Dirac-Operatoren und Killing-Spinoren mit Torsion

    Energy Technology Data Exchange (ETDEWEB)

    Becker-Bender, Julia

    2012-12-17

    On a Riemannian spin manifold with parallel skew torsion, we use the twistor operator to obtain an eigenvalue estimate for the Dirac operator with torsion. We consider the equality case in dimensions four and six. In odd dimensions we describe Sasaki manifolds on which equality in the estimate is realized by Killing spinors with torsion. In dimension five we characterize all Killing spinors with torsion and obtain certain naturally reductive spaces as exceptional cases.

  14. Ultimate Strength of Ship Hulls under Torsion

    DEFF Research Database (Denmark)

    Paik, Jeom Kee; Thayamballi, Anil K.; Pedersen, Preben Terndrup

    2001-01-01

    subjected to torsion. A procedure for calculating these stresses is briefly described. As an illustrative example, the distribution and magnitude of warping and shear stresses for a typical container vessel hull cross section under unit torsion is calculated by the procedure. By theoretical and numerical...... analyses, it is shown that the influence of torsion induced warping stresses on the ultimate hull girder bending strength is small for ductile hull materials while torsion induced shear stresses will of course reduce the ship hull ultimate bending moment....

  15. Primary splenic torsion in a Boston terrier

    International Nuclear Information System (INIS)

    Ohta, H.; Takagi, S.; Murakami, M.; Sasaki, N.; Yoshikawa, M.; Nakamura, K.; Hwang, S.J.; Yamasaki, M.; Takiguchi, M.

    2009-01-01

    A 7-year-old female Boston terrier was referred to Hokkaido University Veterinary Teaching Hospital with a history of hemoglobinuria and anemia for several days. Abdominal radiographs showed splenomegaly, and ultrasonography revealed a hypoechoic splenic parenchyma with interspersed linear echoes consistent with the ultrasonographic appearance of splenic torsion. Ultrasonography and computed tomography (CT) indicated a C-shaped spleen. Exploratory laparotomy confirmed the diagnosis of splenic torsion. A splenectomy was performed, and the dog recovered well without complications. This is the first report of splenic torsion in Boston terriers, and the usefulness of ultrasonographic and CT findings of the splenic torsion was also confirmed

  16. Primary splenic torsion in a Boston terrier.

    Science.gov (United States)

    OHTA, Hiroshi; TAKAGI, Satoshi; MURAKAMI, Masahiro; SASAKI, Noboru; YOSHIKAWA, Muneyoshi; NAKAMURA, Kensuke; HWANG, Shiang-Jyi; YAMASAKI, Masahiro; TAKIGUCHI, Mitsuyoshi

    2009-11-01

    A 7-year-old female Boston terrier was referred to Hokkaido University Veterinary Teaching Hospital with a history of hemoglobinuria and anemia for several days. Abdominal radiographs showed splenomegaly, and ultrasonography revealed a hypoechoic splenic parenchyma with interspersed linear echoes consistent with the ultrasonographic appearance of splenic torsion. Ultrasonography and computed tomography (CT) indicated a C-shaped spleen. Exploratory laparotomy confirmed the diagnosis of splenic torsion. A splenectomy was performed, and the dog recovered well without complications. This is the first report of splenic torsion in Boston terriers, and the usefulness of ultrasonographic and CT findings of the splenic torsion was also confirmed.

  17. Mechanical properties of fasteners -- Part 7: Torsional test and minimum torques for bolts and screws with nominal diameters 1 mm to 10 mm

    CERN Document Server

    International Organization for Standardization. Geneva

    1992-01-01

    Applies to bolts and screws of property classes 8.8 to 12.9 in accordance with ISO 898-1 with thread less than M3 for which no breaking and proof loads are indicated in ISO 898-1, as well as to short bolts and screws with nominal diameters 3 mm to 10 mm which cannot be subjected to a tensile test. The minimum breaking torques are not valid for hexagon socket set screws.

  18. Effect of torsional loading of nickel-titanium instruments on cyclic fatigue resistance.

    Science.gov (United States)

    Cheung, Gary Shun-Pan; Oh, Seung-Hei; Ha, Jung-Hong; Kim, Sung Kyo; Park, Se-Hee; Kim, Hyeon-Cheol

    2013-12-01

    The aim of this study was to evaluate the effect of torsional preload on the cyclic fatigue life of nickel-titanium rotary instruments. ProFile (#25/0.06) (Dentsply Maillefer, Ballaigues, Switzerland) and ProTaper (F1; Dentsply Maillefer) were used. Each file was preloaded at 4 conditions (ie, no preloading and 25%, 50%, and 75% of mean ultimate torsional strength) of torsional prestress before the fatigue test. The torsional preloads were applied by securing 5 mm of the file tip while keeping the file straight, rotating it clockwise until the preset torque, and then returning to the original position. This motion was repeated until a preset number (10, 30, or 50) of repetitions were reached (n = 12). After torsional preloading, the number of cycles to failure was evaluated in a simulated canal. Data were analyzed using 2-way analysis of variance and the Duncan post hoc comparison. The fractured fragment surfaces were examined under a scanning electron microscope for the topographic features of fractured instruments. For both instruments, there was a significant effect because of the extent of torsional preloads. The 50% and 75% torsionally preloaded ProFile and all ProTaper preloading groups had a higher number of cycles to failure than the other group(s). There was little difference in the lateral view appearance between new and torsionally preloaded files. After cyclic fatigue testing, all preloaded instruments showed numerous microcracks adjacent to the fracture site on lateral view examination. The microcracks did not seem to follow the machining grooves on the instrument surface but rather ran irregularly. The torsional preloads within the superelastic limit of the material may improve the cyclic fatigue resistance of nickel-titanium rotary instruments. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  19. Contribution of facet joints, axial compression, and composition to human lumbar disc torsion mechanics.

    Science.gov (United States)

    Bezci, Semih E; Eleswarapu, Ananth; Klineberg, Eric O; O'Connell, Grace D

    2018-02-12

    Stresses applied to the spinal column are distributed between the intervertebral disc and facet joints. Structural and compositional changes alter stress distributions within the disc and between the disc and facet joints. These changes influence the mechanical properties of the disc joint, including its stiffness, range of motion, and energy absorption under quasi-static and dynamic loads. There have been few studies evaluating the role of facet joints in torsion. Furthermore, the relationship between biochemical composition and torsion mechanics is not well understood. Therefore, the first objective of this study was to investigate the role of facet joints in torsion mechanics of healthy and degenerated human lumbar discs under a wide range of compressive preloads. To achieve this, each disc was tested under four different compressive preloads (300-1200 N) with and without facet joints. The second objective was to develop a quantitative structure-function relationship between tissue composition and torsion mechanics. Facet joints have a significant contribution to disc torsional stiffness (∼60%) and viscoelasticity, regardless of the magnitude of axial compression. The findings from this study demonstrate that annulus fibrosus GAG content plays an important role in disc torsion mechanics. A decrease in GAG content with degeneration reduced torsion mechanics by more than an order of magnitude, while collagen content did not significantly influence disc torsion mechanics. The biochemical-mechanical and compression-torsion relationships reported in this study allow for better comparison between studies that use discs of varying levels of degeneration or testing protocols and provide important design criteria for biological repair strategies. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  20. Simultaneous acute appendicitis with right testicular torsion

    Directory of Open Access Journals (Sweden)

    Tanveer Akhtar

    2012-01-01

    Full Text Available We present a child with both acute appendicitis and torsion of the right testis presenting at the same time. Testicular torsion possibly occurring due to vomiting in acute appendicitis so far has not been reported in the literature.

  1. Teenage testicular torsion. | Onuigbo | International Journal of ...

    African Journals Online (AJOL)

    Aim: To study testicular torsion in teenagers in the Igbo community. Method: A retrospective study was carried out as regards requests for pathological examination of specimens received at a Regional Reference Laboratory based in Enugu. Results: Over a period of 30 years, 28 surgical specimens of testicular torsion in ...

  2. Misdiagnosed Adult Testicular Torsion: Case Report | Ndaguatha ...

    African Journals Online (AJOL)

    Adult testicular torsion is thought to be rare if not relatively unusual. The rarity could be an underestimation since there are many episodes of missed torsions and misdiagnosis with other conditions of acute scrotum despite the now widespread ultra sound availability that are being reported in the literature. Such a ...

  3. Appendicular Torsion | Dubhashi | Nigerian Journal of Surgery

    African Journals Online (AJOL)

    . It can be primary or secondary. This is a case report of 52-year-old female with 180° anti-clockwise rotation of the appendix. Torsion can further leads to strangulation and infarction of the organ. Appendicular torsion could be included in the ...

  4. Experimental investigation on rectangular reinforced concrete beam subjected to bi-axial shear and torsion

    Directory of Open Access Journals (Sweden)

    Chayanon Hansapinyo

    2003-01-01

    Full Text Available This paper presents the experimental investigation on the failure mechanism and ultimate capacity of rectangular reinforced concrete beam under combined action of bi-axial shear accompanied with torsion through the test of four reinforced concrete members. The simple experimental set-up for a simply-supported beam under one point loading is introduced in this study by applying eccentric load to the tilted beam. This requires only one hydraulic jack to produce the complicated bi-axial shear and torsional loading. The main parameter is the magnitude of torsion induced to specimens which is relatively represented by the torsion-to-shear ratio. In addition, the influence of torsion on ultimate capacity of reinforced concrete with different ratio of two shears is investigated. From the experimental results, it is found that the increase in the magnitude of torsion about 69 percent drastically decreases bi-axial shear capacity as much as 12 to 39 percent according to the ratio of bi-axial shears. The experimental results are compared with the capacities calculated by the available interaction formula between uni-axial shear and torsion in the current design codes. The comparison indicates that the current design codes give quite conservative values of ultimate capacity.

  5. Ocular torsion produced by unilateral chemical inactivation of the cerebellar flocculus in alert cats.

    Science.gov (United States)

    Chin, Shinki; Fukushima, Kikuro; Fukushima, Junko; Kase, Manabu; Ohno, Shigeaki

    2002-09-01

    Vertical eye movements are executed by the vertical recti and oblique muscle pairs. Since each of these pairs rotates the eye in both vertical and torsional directions, torsional components must be controlled to execute appropriate, purely vertical eye movements. To test whether the cerebellar flocculus is involved in the control of torsional eye position, we examined the effects of unilateral chemical inactivation of the flocculus on ocular torsion in alert cats. Pitch-responding floccular regions were first identified, then the GABA agonist muscimol was injected unilaterally into the identified regions. Ocular torsion was examined photographically. Unilateral muscimol infusion into pitch-responding areas in the rostral and middle parts of the flocculus resulted in significant intorsion of the eye ipsilateral to the infusion. Gaze-holding was also impaired following downward saccades induced by visual stimuli. Although the contralateral eye showed a tendency towards extorsion, the effects were not significant. Muscimol infusion into the caudal flocculus did not induce consistent effects on ocular torsion. The cerebellar flocculus plays a key role in the maintenance of torsional eye position.

  6. An Assessment of Cumulative Axial and Torsional Fatigue in a Cobalt-Base Superalloy

    Science.gov (United States)

    Kalluri, Sreeramesh; Bonacuse, Peter J.

    2010-01-01

    Cumulative fatigue under axial and torsional loading conditions can include both load-order (higMow and low/high) as well as load-type sequence (axial/torsional and torsional/axial) effects. Previously reported experimental studies on a cobalt-base superalloy, Haynes 188 at 538 C, addressed these effects. These studies characterized the cumulative axial and torsional fatigue behavior under high amplitude followed by low amplitude (Kalluri, S. and Bonacuse, P. J., "Cumulative Axial and Torsional Fatigue: An Investigation of Load-Type Sequance Effects," in Multiaxial Fatigue and Deformation: Testing and Prediction, ASTM STP 1387, S. Kalluri, and P. J. Bonacuse, Eds., American Society for Testing and Materials, West Conshohocken, PA, 2000, pp. 281-301) and low amplitude followed by high amplitude (Bonacuse, P. and Kalluri, S. "Sequenced Axial and Torsional Cumulative Fatigue: Low Amplitude Followed by High Amplitude Loading," Biaxial/Multiaxial Fatigue and Fracture, ESIS Publication 31, A. Carpinteri, M. De Freitas, and A. Spagnoli, Eds., Elsevier, New York, 2003, pp. 165-182) conditions. In both studies, experiments with the following four load-type sequences were performed: (a) axial/axial, (b) torsional/torsional, (c) axial/torsional, and (d) torsional/axial. In this paper, the cumulative axial and torsional fatigue data generated in the two previous studies are combined to generate a comprehensive cumulative fatigue database on both the load-order and load-type sequence effects. This comprehensive database is used to examine applicability of the Palmgren-langer-Miner linear damage rule and a nonlinear damage curve approach for Haynes 188 subjected to the load-order and load-type sequencing described above. Summations of life fractions from the experiments are compared to the predictions from both the linear and nonlinear cumulative fatigue damage approaches. The significance of load-order versus load-type sequence effects for axial and torsional loading conditions

  7. Torsional Vibration in the National Wind Technology Center’s 2.5-Megawatt Dynamometer

    Energy Technology Data Exchange (ETDEWEB)

    Sethuraman, Latha [National Renewable Energy Lab. (NREL), Golden, CO (United States); Keller, Jonathan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Wallen, Robb [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-08-31

    This report documents the torsional drivetrain dynamics of the NWTC's 2.5-megawatt dynamometer as identified experimentally and as calculated using lumped parameter models using known inertia and stiffness parameters. The report is presented in two parts beginning with the identification of the primary torsional modes followed by the investigation of approaches to damp the torsional vibrations. The key mechanical parameters for the lumped parameter models and justification for the element grouping used in the derivation of the torsional modes are presented. The sensitivities of the torsional modes to different test article properties are discussed. The oscillations observed from the low-speed and generator torque measurements were used to identify the extent of damping inherently achieved through active and passive compensation techniques. A simplified Simulink model of the dynamometer test article integrating the electro-mechanical power conversion and control features was established to emulate the torque behavior that was observed during testing. The torque response in the high-speed, low-speed, and generator shafts were tested and validated against experimental measurements involving step changes in load with the dynamometer operating under speed-regulation mode. The Simulink model serves as a ready reference to identify the torque sensitivities to various system parameters and to explore opportunities to improve torsional damping under different conditions.

  8. Surface crack growth in cylindrical hollow specimen subject to tension and torsion

    OpenAIRE

    Shlyannikov, V.; Yarullin, R.; Ishtyryakov, I.

    2015-01-01

    The subject for studies is an aluminium cylindrical hollow specimen with external axial and part circumferential semi-elliptical surface crack undergoing fatigue loads. Both the optical microscope measurements and the crack opening displacement (COD) method are used to monitor and calculate both crack depth and crack length during the tests. The variation of crack growth behaviour is studied under cyclic axial tension, pure torsion and combined tension+torsion fatigue loading. For...

  9. Stress Relaxation Of Superelastic Shape Memory Alloy Under Bending And Torsional Load

    Directory of Open Access Journals (Sweden)

    Sakib Tanvir

    2017-04-01

    Full Text Available Stress Relaxation of Superelastic Shape memory NiTi Alloy under bending and torsion is uncommon in literature. Therefore experimental set up has been devised and test results are obtained for superelastic SMA.Unlike the other common engineering materials superelastic SMA it gives dramatic reduction in stress. In this paper therefore results of stress relaxation of superelastic shape memory alloy under bending and torsion are presented graphically and interpreted in terms of stress induced martensitic transformation.

  10. Cyclic Axial-Torsional Deformation Behavior of a Cobalt-Base Superalloy

    Science.gov (United States)

    Bonacuse, Peter J.; Kalluri, Sreeramesh

    1995-01-01

    The cyclic, high-temperature deformation behavior of a wrought cobalt-base super-alloy, Haynes 188, is investigated under combined axial and torsional loads. This is accomplished through the examination of hysteresis loops generated from a biaxial fatigue test program. A high-temperature axial, torsional, and combined axial-torsional fatigue database has been generated on Haynes 188 at 760 C. Cyclic loading tests have been conducted on uniform gage section tubular specimens in a servohydraulic axial-torsional test rig. Test control and data acquisition were accomplished with a minicomputer. The fatigue behavior of Haynes 188 at 760 C under axial, torsional, and combined axial-torsional loads and the monotonic and cyclic deformation behaviors under axial and torsional loads have been previously reported. In this paper, the cyclic hardening characteristics and typical hysteresis loops in the axial stress versus axial strain, shear stress ,versus engineering shear strain, axial strain versus engineering shear strain. and axial stress versus shear stress spaces are presented for cyclic in-phase and out-of-phase axial-torsional tests. For in-phase tests, three different values of the proportionality constant lambda (the ratio of engineering shear strain amplitude to axial strain amplitude, are examined, viz. 0.86, 1.73, and 3.46. In the out-of-phase tests, three different values of the phase angle, phi (between the axial and engineering shear strain waveforms), are studied, viz., 30, 60, and 90 degrees with lambda equals 1.73. The cyclic hardening behaviors of all the tests conducted on Haynes 188 at 760 C are evaluated using the von Mises equivalent stress-strain and the maximum shear stress-maximum engineering shear strain (Tresca) curves. Comparisons are also made between the hardening behaviors of cyclic axial, torsional, and combined in-phase (lambda = 1.73 and phi = 0) and out-of-phase (lambda = 1.73 and phi = 90') axial-torsional fatigue tests. These comparisons

  11. Inferior oblique weakening surgery on ocular torsion in congenital superior oblique palsy

    Directory of Open Access Journals (Sweden)

    Jinho Lee

    2015-06-01

    Full Text Available AIM:To investigate changes in fundus excyclotorsion after inferior oblique myectomy or myotomy.METHODS:The records of 21 patients undergoing strabismus surgery by a single surgeon between 2009 and 2012 were examined. Only patients who had undergone an inferior oblique myectomy or myotomy, with or without horizontal rectus muscle surgery, were evaluated. Digital fundus photographs were obtained, and the angle formed by a horizontal line passing through the optic disc center and a reference line connecting the foveola and optic disc center was measured. Associated clinical factors examined include age at the time of surgery, presence or absence of a head tilt, degree of preoperative vertical deviation, torsional angle, inferior oblique muscle overaction/superior oblique muscle underaction, and surgery laterality. Whether the procedure was performed alone or in combination with a horizontal rectus muscle surgery was also examined.RESULTS:Mean preoperative torsional angle was 12.0±6.4°, which decreased to 6.9±5.7° after surgery (P<0.001, paired t-test. Torsional angle also decreased from 15.1±7.0° to 6.2±4.3° in the myectomy group (P<0.001, paired t-test but there were no significant changes in the myotomy group (P=0.093, Wilcoxon signed rank test. Multivariable linear regression analysis showed that preoperative torsional angle, degree of inferior oblique overaction, and age at surgery independently and significantly affected postoperative torsional angle.CONCLUSION:Mean torsional angle decreased after inferior oblique myectomy. Degree of preoperative torsional angle, inferior oblique overaction, and age at surgery influence postoperative torsional angle.

  12. Torsion of the vermiform appendix: A case report | Wani | Internet ...

    African Journals Online (AJOL)

    Torsion of the vermiform appendix is a rare condition with few cases reported in the literature. Various factors predispose to torsion. Various factors predispose to torsion. We report a case of primary torsion of the vermiform appendix. The clinical presentation was indistinguishable from acute appendicitis and the diagnosis ...

  13. Measurement of tibial torsion by computer tomography

    International Nuclear Information System (INIS)

    Jend, H.-H.; Heller, M.; Dallek, M.; Schoettle, H.

    1981-01-01

    A CT procedure for objective measurements of tibial torsion independent of axial rotation in the nearby joints is described. Transverse sections in defined planes of the tibia permit easy calculation of normal and abnormal congenital or posttraumatic angles of torsion. In 69 limbs normal tibial torsion was 40 0 +-9 0 . In a series of 42 limbs with complicated healing of a fracture of both bones of the leg it is shown that tibial maltorsion is a deformity which in most cases leads to arthrosis of the ankle joint. (Auth.)

  14. Measurement of tibial torsion by computer tomography

    Energy Technology Data Exchange (ETDEWEB)

    Jend, H.H.; Heller, M.; Dallek, M.; Schoettle, H. (Hamburg Univ. (Germany, F.R.))

    1981-01-01

    A CT procedure for objective measurements of tibial torsion independent of axial rotation in the nearby joints is described. Transverse sections in defined planes of the tibia permit easy calculation of normal and abnormal congenital or posttraumatic angles of torsion. In 69 limbs normal tibial torsion was 40/sup 0/+-9/sup 0/. In a series of 42 limbs with complicated healing of a fracture of both bones of the leg it is shown that tibial maltorsion is a deformity which in most cases leads to arthrosis of the ankle joint.

  15. Torsional strength of computer-aided design/computer-aided manufacturing-fabricated esthetic orthodontic brackets.

    Science.gov (United States)

    Alrejaye, Najla; Pober, Richard; Giordano Ii, Russell

    2017-01-01

    To fabricate orthodontic brackets from esthetic materials and determine their fracture resistance during archwire torsion. Computer-aided design/computer-aided manufacturing technology (Cerec inLab, Sirona) was used to mill brackets with a 0.018 × 0.025-inch slot. Materials used were Paradigm MZ100 and Lava Ultimate resin composite (3M ESPE), Mark II feldspathic porcelain (Vita Zahnfabrik), and In-Ceram YZ zirconia (Vita Zahnfabrik). Ten brackets of each material were subjected to torque by a 0.018 × 0.025-inch stainless steel archwire (G&H) using a specially designed apparatus. The average moments and degrees of torsion necessary to fracture the brackets were determined and compared with those of commercially available alumina brackets, Mystique MB (Dentsply GAC). The YZ brackets were statistically significantly stronger than any other tested material in their resistance to torsion (P 3467 g.mm for Mark II to 11,902 g.mm for YZ. The mean torsion angles at failure ranged from 15.3° to 40.9°. Zirconia had the highest torsional strength among the tested esthetic brackets. Resistance of MZ100 and Lava Ultimate composite resin brackets to archwire torsion was comparable to commercially available alumina ceramic brackets.

  16. Tensile and Torsional Structural Properties of the Native Scapholunate Ligament.

    Science.gov (United States)

    Pang, Eric Quan; Douglass, Nathan; Behn, Anthony; Winterton, Matthew; Rainbow, Michael J; Kamal, Robin N

    2018-02-17

    The ideal material for reconstruction of the scapholunate interosseous ligament (SLIL) should replicate the mechanical properties of the native SLIL to recreate normal kinematics and prevent posttraumatic arthritis. The purpose of our study was to evaluate the cyclic torsional and tensile properties of the native SLIL and load to failure tensile properties of the dorsal SLIL. The SLIL bone complex was resected from 10 fresh-frozen cadavers. The scaphoid and lunate were secured in polymethylmethacrylate and mounted on a test machine that incorporated an x-y stage and universal joint, which permitted translations perpendicular to the rotation/pull axis as well as nonaxial angulations. After a 1 N preload, specimens underwent cyclic torsional testing (±0.45 N m flexion/extension at 0.5 Hz) and tensile testing (1-50 N at 1 Hz) for 500 cycles. Lastly, the dorsal 10 mm of the SLIL was isolated and displaced at 10 mm/min until failure. During intact SLIL cyclic torsional testing, the neutral zone was 29.7° ± 6.6° and the range of rotation 46.6° ± 7.1°. Stiffness in flexion and extension were 0.11 ± 0.02 and 0.12 ± 0.02 N m/deg, respectively. During cyclic tensile testing, the engagement length was 0.2 ± 0.1 mm, the mean stiffness was 276 ± 67 N/mm, and the range of displacement was 0.4 ± 0.1 mm. The dorsal SLIL displayed a 0.3 ± 0.2 mm engagement length, 240 ± 65 N/mm stiffness, peak load of 270 ± 91 N, and displacement at peak load of 1.8 ± 0.3 mm. We report the torsional properties of the SLIL. Our novel test setup allows for free rotation and translation, which reduces out-of-plane force application. This may explain our observation of greater dorsal SLIL load to failure than previous reports. By matching the natural ligament with respect to its tensile and torsional properties, we believe that reconstructions will better restore the natural kinematics of the wrist and lead to improved outcomes. Future clinical studies should aim to investigate this

  17. Influence of temperature changes on torsional rigidity and damping coefficient of rubber torsional vibration damper

    Directory of Open Access Journals (Sweden)

    Wojciech HOMIK

    2011-01-01

    Full Text Available The short explanation of usefulness of rubber torsional dampers in crankshaft in multi-cylinder engines is presented. The description of the construction and operation of rubber torsional damper is also included. In the rubber torsional damper, the damping is achieved as the effect of internal friction resulting from the deformation of the rubber material. This deformation appears while the internal rubber elasticity is overloaded. Both the physical and mechanical rubber properties depend on temperature change. In cooperation with rubber dampers manufacturer the experimental investigations are made in order to establish the influence of temperature change on torsional stiffness and damping.

  18. Net-section-collapse of circumferentially cracked cylinders subjected to torsional moment

    International Nuclear Information System (INIS)

    Miura, Naoki; Hoshino, Katsuaki; Li, Yinsheng; Doi, Hiroaki

    2011-01-01

    When a flaw is detected in austenitic piping during in-service inspection, the limit load criterion given in the codes such as JSME Rules on Fitness-for-Service for Nuclear Power Plants or ASME Boiler and Pressure Vessel Code Section XI can be applied to evaluate the structural integrity of the piping. Considering that a cracked pipe is subjected to tensile load and/or bending moment, limit load (moment) for ductile material can be well predicted based on the net-section-collapse criterion derived from the equilibrium of the admissible stress distribution on the ligament of the cracked section. Actual piping is generally subjected to combined tensile, bending, and torsional loadings, however, a methodology to evaluate limit moment for torsion is not established due to the inadequacy of experimental validation. In this study, fracture tests for circumferentially cracked cylinders subjected to torsional moment were conducted. Tested material was austenitic stainless steel, and the shape and size of crack were variable. Experimental maximum moments were compared with the limit moments, which were evaluated based on the concept of the net-section-collapse criterion for torsional moment. The maximum moments could be conservatively predicted by the net-section-collapse criterion. In addition, an innovative test method was developed to conduct torsional tests using a pair of Charpy V-notch specimens and a conventional test machine. The adequacy of the replacement of cracks with machined notches for ductile materials under torsional loading was investigated through the comparison of the fracture behavior obtained from notched and precracked Charpy specimens. The developed method could be an alternative test method for torsional moment. (author)

  19. Isolated torsion of fallopian tube. Radiological findings

    International Nuclear Information System (INIS)

    Tomas Fanjul, L.; Aldea Martinez, J.; Fernandez Matia, G.; Rodrigo Verguizas, J.; Fernandez Alvarez, G.; Galindo Vicente, M.C.

    1993-01-01

    Isolated tubal torsion is a very uncommon disorder that is rarely diagnosed preoperatively. We present a case and review the literature, which only provides ultrasonographic findings in 5 cases reported to date. 11 refs

  20. Torsion sensing based on patterned piezoelectric beams

    Science.gov (United States)

    Cha, Youngsu; You, Hangil

    2018-03-01

    In this study, we investigated the sensing characteristics of piezoelectric beams under torsional loads. We used partially patterned piezoelectric beams to sense torsion. In particular, the piezoelectric patches are located symmetrically with respect to the line of the shear center of the beam. The patterned piezoelectric beam is modeled as a slender beam, and its electrical responses are obtained by piezoelectric electromechanical equations. To validate the modeling framework, experiments are performed using a setup that forces pure torsional deformation. Three different geometric configurations of the patterned piezoelectric layer are used for the experiments. The frequency and amplitude of the forced torsional load are systematically varied in order to study the behavior of the piezoelectric sensor. Experimental results demonstrate that two voltage outputs of the piezoelectric beam are approximately out of phase with identical amplitude. Moreover, the length of the piezoelectric layers has a significant influence on the sensing properties. Our theoretical predictions using the model support the experimental findings.

  1. Internal torsion resistance in deflected shafts

    Directory of Open Access Journals (Sweden)

    Mahmoud T. El-Sayed

    2017-06-01

    The objective of the present work was to estimate the effect of internal torsional resistance in shafts which is caused by deflection, for the reason that it has the upper hand on misalignment problem. With the aim of fulfilling this objective, an experimental rig has been constructed to verify the existence of the torsional resistance in deflected shafts and its variation with the rotation angle.

  2. Torsion and geometrostasis in covariant superstrings

    Energy Technology Data Exchange (ETDEWEB)

    Zachos, C.

    1985-01-01

    The covariant action for freely propagating heterotic superstrings consists of a metric and a torsion term with a special relative strength. It is shown that the strength for which torsion flattens the underlying 10-dimensional superspace geometry is precisely that which yields free oscillators on the light cone. This is in complete analogy with the geometrostasis of two-dimensional sigma-models with Wess-Zumino interactions. 13 refs.

  3. Torsion of Wandering Gallbladder following Colonoscopy

    Directory of Open Access Journals (Sweden)

    Sean R. Warfe

    2013-01-01

    Full Text Available Torsion of the gallbladder is an uncommon condition that may present as an acute abdomen. Its preoperative diagnosis can often be challenging due to its variable presentation, with specific sonographic signs seen infrequently. We describe, to our knowledge, the first case of torsion of a wandering gallbladder following a colonoscopy in a 69-year-old female who presented with acute abdominal pain after procedure. This was discovered intraoperatively, and after a subsequent cholecystectomy, she had an uncomplicated recovery.

  4. Attentional Modulation of Eye Torsion Responses

    Science.gov (United States)

    Stevenson, Scott B.; Mahadevan, Madhumitha S.; Mulligan, Jeffrey B.

    2016-01-01

    Eye movements generally have both reflexive and voluntary aspects, but torsional eye movements are usually thought of as a reflexive response to image rotation around the line of sight (torsional OKN) or to head roll (torsional VOR). In this study we asked whether torsional responses could be modulated by attention in a case where two stimuli rotated independently, and whether attention would influence the latency of responses. The display consisted of rear-projected radial "pinwheel" gratings, with an inner annulus segment extending from the center to 22 degrees eccentricity, and an outer annulus segment extending from 22 degrees out to 45 degrees eccentricity. The two segments rotated around the center in independent random walks, stepping randomly 4 degrees clockwise or counterclockwise at 60 Hz. Subjects were asked to attend to one or the other while keeping fixation steady at the center of the display. To encourage attention on one or the other segment of the display, subjects were asked to move a joystick in synchrony with the back and forth rotations of one part of the image while ignoring the other. Eye torsion was recorded with the scleral search coil technique, sampled at 500 Hz. All four subjects showed roughly 50% stronger torsion responses to the attended compared to unattended segments. Latency varied from 100 to 150 msec across subjects and was unchanged by attention. These findings suggest that attention can influence eye movement responses that are not typically under voluntary control.

  5. Torsional and axial compressive properties of tibiotarsal bones of red-tailed hawks (Buteo jamaicensis).

    Science.gov (United States)

    Kerrigan, Shannon M; Kapatkin, Amy S; Garcia, Tanya C; Robinson, Duane A; Guzman, David Sanchez-Migallon; Stover, Susan M

    2018-04-01

    OBJECTIVE To describe the torsional and axial compressive properties of tibiotarsal bones of red-tailed hawks (Buteo jamaicensis). SAMPLE 16 cadaveric tibiotarsal bones from 8 red-tailed hawks. PROCEDURES 1 tibiotarsal bone from each bird was randomly assigned to be tested in torsion, and the contralateral bone was tested in axial compression. Intact bones were monotonically loaded in either torsion (n = 8) or axial compression (8) to failure. Mechanical variables were derived from load-deformation curves. Fracture configurations were described. Effects of sex, limb side, and bone dimensions on mechanical properties were assessed with a mixed-model ANOVA. Correlations between equivalent torsional and compressive properties were determined. RESULTS Limb side and bone dimensions were not associated with any mechanical property. During compression tests, mean ultimate cumulative energy and postyield energy for female bones were significantly greater than those for male bones. All 8 bones developed a spiral diaphyseal fracture and a metaphyseal fissure or fracture during torsional tests. During compression tests, all bones developed a crushed metaphysis and a fissure or comminuted fracture of the diaphysis. Positive correlations were apparent between most yield and ultimate torsional and compressive properties. CONCLUSIONS AND CLINICAL RELEVANCE The torsional and axial compressive properties of tibiotarsal bones described in this study can be used as a reference for investigations into fixation methods for tibiotarsal fractures in red-tailed hawks. Although the comminuted and spiral diaphyseal fractures induced in this study were consistent with those observed in clinical practice, the metaphyseal disruption observed was not and warrants further research.

  6. A STUDY ON TIBIAL TORSION IN ADULT DRY TIBIA OF EAST AND SOUTH INDIAN POPULATION

    Directory of Open Access Journals (Sweden)

    Jami Sagar Prusti

    2017-05-01

    Full Text Available BACKGROUND Rotational deformities of the lower limbs are very common. There is increasing evidence that abnormal torsion in the tibia is associated with severe knee and ankle arthritis. Primary knee osteoarthritis is a leading cause of disability in older persons. Varus or valgus alignment increases the risk of osteoarthritis. Coexistence of tibial torsional deformity may increase the risk further. Variability in the tibial torsion has been reported and is due to the torsional forces applied on tibia during development. The aim of the study is to estimate the angle of tibial torsion on both sides and both sexes. The present study was an attempt to provide baseline data of tibial torsion in the East and South Indian population. MATERIALS AND METHODS The study was conducted mechanically on 100 dry adult unpaired human tibia, i.e. 50 male and 50 female bones. The measurements were recorded and statistically analysed using Student’s unpaired t-test using GraphPad Prism 5.0 (free trial version. RESULTS Out of the 100 tibia undertaken, mean value of tibial torsion angle obtained is 25.8°. In males, it is 23.68° and in females it is about 27.86°. Statistical analysis revealed significant greater average angle of tibial torsion in female bones. The angle of the right-sided bones was more and this was statistically significant. CONCLUSION The gender variation for the angle could be the result of the difference in lifestyle in day-to-day activities. The knowledge of the angle in a population could be helpful in understanding the incidence of pathogenesis related to gait and knee osteoarthritis and in view of reconstructive surgeries in orthopaedic practice.

  7. Biomechanics of lumbosacral spinal fusion in combined compression-torsion loads.

    Science.gov (United States)

    Yang, S W; Langrana, N A; Lee, C K

    1986-11-01

    The current study investigates the stabilizing effects of three different types of spinal fusion to the juxta-free motion segments and to the fused segment of the lumbosacral spine under combined compression-torsion loads. Sixteen fresh human cadaver lumbosacral spines were tested under a simulated physiologic loading condition. The relative movements of the motion segments, as well as the angular rotations and the center of rotation were then computed and analyzed. The average torsional stiffness of the unfused three-motion segment was found to be 2.35 nm/degree. After fusion, the torsional stiffness did not increase significantly. Under the compression-torsional load, the anterior and bilateral-lateral fusions provided adequate stabilizing effect on the fused segment. The posterior fusion provided the least amount of stabilizing effect. These findings are similar to the results of the compression-bending experiment. Whereas the compression-bending loads produced significantly increased stress at the juxta-free segments, the compression-torsional loads did not produce any significant amount of increase in torsional stress at the juxta-free segments.

  8. MSTor version 2013: A new version of the computer code for the multi-structural torsional anharmonicity, now with a coupled torsional potential

    Science.gov (United States)

    Zheng, Jingjing; Meana-Pañeda, Rubén; Truhlar, Donald G.

    2013-08-01

    partition functions using the torsional eigenvalue summation method. Additional comments: The program package includes a manual, installation script, and input and output files for a test suite. Running time: There are 26 test runs. The running time of the test runs on a single processor of the Itasca computer is less than 2 s. References: [1] MS-T(C) method: Quantum Thermochemistry: Multi-Structural Method with Torsional Anharmonicity Based on a Coupled Torsional Potential, J. Zheng and D.G. Truhlar, Journal of Chemical Theory and Computation 9 (2013) 1356-1367, DOI: http://dx.doi.org/10.1021/ct3010722. [2] MS-T(U) method: Practical Methods for Including Torsional Anharmonicity in Thermochemical Calculations of Complex Molecules: The Internal-Coordinate Multi-Structural Approximation, J. Zheng, T. Yu, E. Papajak, I, M. Alecu, S.L. Mielke, and D.G. Truhlar, Physical Chemistry Chemical Physics 13 (2011) 10885-10907.

  9. Torsional oscillations of strange stars

    Directory of Open Access Journals (Sweden)

    Mannarelli Massimo

    2014-01-01

    Full Text Available Strange stars are one of the hypothetical compact stellar objects that can be formed after a supernova explosion. The existence of these objects relies on the absolute stability of strange collapsed quark matter with respect to standard nuclear matter. We discuss simple models of strange stars with a bare quark matter surface, thus standard nuclear matter is completely absent. In these models an electric dipole layer a few hundreds Fermi thick should exist close to the star surface. Studying the torsional oscillations of the electrically charged layer we estimate the emitted power, finding that it is of the order of 1045 erg/s, meaning that these objects would be among the brightest compact sources in the heavens. The associated relaxation times are very uncertain, with values ranging between microseconds and minutes, depending on the crust thickness. Although part of the radiated power should be absorbed by the electrosphere surrounding the strange star, a sizable fraction of photons should escape and be detectable.

  10. Effect of Torsional and Fatigue Preloading on HyFlex EDM Files.

    Science.gov (United States)

    Shen, Ya; Tra, Charles; Hieawy, Ahmed; Wang, Zhejun; Haapasalo, Markus

    2018-04-01

    The purpose of this study was to evaluate the effect of a low amount of torsional preloading on the fatigue life and different degrees of cyclic fatigue on torsional failure of HyFlex EDM (EDM; Coltene-Whaledent, Allstetten, Switzerland) and HyFlex CM (CM; Coltene-Whaledent) instruments. EDM and CM files were used. The fatigue resistance was examined in a 5-mm radius and 60° single curve, and the mean number of cycles to failure (N f ) was recorded. The torque and rotation angles at failure of the instruments were measured according to ISO 3630-1. New files were precycled to 0%, 50%, and 75% of the N f , and torsional tests were then performed. Other new files were preloaded at 5%, 15%, 25%, and 50% of the mean rotation angles before the fatigue test. The fracture surfaces of the fragments were examined under a scanning electron microscope. The fatigue resistance of EDM instruments was higher than that of CM instruments (P EDM at 15% preloading (P EDM files even with 50% torsional preloading was significantly higher than unused CM files (P EDM files. Moderate precycling (50%) of EDM files increased their torsional resistance. The fractographic patterns corresponded to the pattern defined by the last stage test. A low amount (15%) of torsional preloading reduced the fatigue resistance of EDM files, whereas even extensive (75%) precyclic fatigue was not detrimental to their torsional resistance. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  11. The influence of ocular sighting dominance on Fundus torsion in patients with unilateral congenital superior oblique palsy.

    Science.gov (United States)

    Kim, Dae Hee; Kim, Hyuna; Lim, Hyun Taek

    2017-12-01

    The purpose of our study was to determine whether ocular sighting dominance may influence the ocular torsion in patients with unilateral congenital superior oblique palsy (UCSOP). This retrospective study included 22 UCSOP patients with radiologic evidence of unilateral superior oblique muscle hypoplasia on orbital magnetic resonance imaging and 66 healthy individuals with normal ocular motility as controls. Ocular torsion was assessed both quantitatively and qualitatively using digital fundus photography. The disc-fovea angle (DFA) was measured quantitatively using image software on a computer screen. All fundus photographs were qualitatively graded as normal torsion, extorsion, or intorsion in all subjects, based on the location of the optic disc relative to the fovea, according to the Bixenman and von Noorden's criteria. Ocular sighting dominance was assessed by the hole-in-the-card test and the pointing test. The Mann-Whitney U test and Fisher's exact test were used to determine the association between the ocular sighting dominance and the ocular torsion. The median DFA was significantly larger in the eyes of patients with UCSOP (9.1° in the paretic eyes and 9.3° in the non-paretic eyes) than the eyes of the control group (4.3°, p extorsion, none had intorsion, and all the eyes of remaining 12 patients had no abnormal torsion, qualitatively. All the eyes showing extorsion in fundus photography were non-dominant eyes, regardless of whether the eyes were paretic or non-paretic. Our findings illuminate the importance of considering ocular sighting dominance for properly assessing ocular torsion in patients with UCSOP. Ocular sighting dominance may have an influence on objective ocular torsion in a way that decreases the torsion in the dominant eye, thereby hindering the abnormal ocular torsion from appearing in that eye.

  12. Comparison of subjective and objective torsion in patients with acquired unilateral superior oblique muscle palsy.

    Science.gov (United States)

    Roh, Young-Rae; Hwang, Jeong-Min

    2011-11-01

    To compare objective torsion, measured using fundus photography, and subjective torsion, measured with the Lancaster red-green test (LRGT) or double Maddox rod test (DMRT), in patients with acquired unilateral superior oblique palsy (SOP). Full ophthalmic examinations, including the alternate prism and cover test, ductions/versions, three-step test, LRGT, DMRT and fundus photography, were performed in 35 consecutive patients (28 men and 7 women) (mean age, 50.4 ± 16.2 years) with acquired unilateral SOP. The correlation between the amount of torsion measured with fundus photography, the LRGT and DMRT was analysed using linear regression analyses. The LRGT, DMRT and fundus photography revealed extorsion in 16 (46%), 21 (91%) and 35 eyes (100%), respectively. There were no significant correlations between the amounts of torsion measured with the LRGT, the DMRT and fundus photography. There was a statistically significant correlation between SOP duration and the amount of torsion only when measured by the LRGT (p=0.0006). Objective extorsion may be found in all patients with acquired unilateral SOP, whereas subjective extorsion may be found in most patients with acquired unilateral SOP; the latter was detected more frequently with the DMRT than with the LRGT.

  13. Torsion profiling of proteins using magnetic particles.

    Science.gov (United States)

    van Reenen, A; Gutiérrez-Mejía, F; van IJzendoorn, L J; Prins, M W J

    2013-03-05

    We report a method to profile the torsional spring properties of proteins as a function of the angle of rotation. The torque is applied by superparamagnetic particles and has been calibrated while taking account of the magnetization dynamics of the particles. We record and compare the torsional profiles of single Protein G-Immunoglobulin G (IgG) and IgG-IgG complexes, sandwiched between a substrate and a superparamagnetic particle, for torques in the range between 0.5 × 10(3) and 5 × 10(3) pN·nm. Both molecular systems show torsional stiffening for increasing rotation angle, but the elastic and inelastic torsion stiffnesses are remarkably different. We interpret the results in terms of the structural properties of the molecules. The torsion profiling technique opens new dimensions for research on biomolecular characterization and for research on bio-nanomechanical structure-function relationships. Copyright © 2013 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  14. A unified approach for determining the ultimate strength of RC members subjected to combined axial force, bending, shear and torsion

    OpenAIRE

    Wang, Pu; Huang, Zhen

    2017-01-01

    This paper uses experimental investigation and theoretical derivation to study the unified failure mechanism and ultimate capacity model of reinforced concrete (RC) members under combined axial, bending, shear and torsion loading. Fifteen RC members are tested under different combinations of compressive axial force, bending, shear and torsion using experimental equipment designed by the authors. The failure mechanism and ultimate strength data for the four groups of tested RC members under di...

  15. Influence of cyclic torsional preloading on cyclic fatigue resistance of nickel - titanium instruments.

    Science.gov (United States)

    Pedullà, E; Lo Savio, F; Boninelli, S; Plotino, G; Grande, N M; Rapisarda, E; La Rosa, G

    2015-11-01

    To evaluate the effect of different torsional preloads on cyclic fatigue resistance of endodontic rotary instruments constructed from conventional nickel-titanium (NiTi), M-Wire or CM-Wire. Eighty new size 25, 0.06 taper Mtwo instruments (Sweden & Martina), size 25, 0.06 taper HyFlex CM (Coltene/Whaledent, Inc) and X2 ProTaper Next (Dentsply Maillefer) were used. The Torque and distortion angles at failure of new instruments (n = 10) were measured, and 0% (n = 10), 25%, 50% and 75% (n = 20) of the mean ultimate torsional strength as preloading condition were applied according to ISO 3630-1 for each brand. The twenty files tested for every extent of preload were subjected to 20 or 40 torsional cycles (n = 10). After torsional preloading, the number of cycles to failure was evaluated in a simulated canal with 60° angle of curvature and 5 mm of radius of curvature. Data were analysed using two-way analysis of variance. The fracture surface of each fragment was examined with a scanning electron microscope (SEM). Data were analysed by two-way analyses of variance. Preload repetitions did not influence the cyclic fatigue of the three brands; however, the 25%, 50% and 75% torsional preloading significantly reduced the fatigue resistance of all instruments tested (P 0.05). Torsional preloads reduced the cyclic fatigue resistance of conventional and treated (M-wire and CM-wire) NiTi rotary instruments except for size 25, 0.06 taper HyFlex CM instruments with a 25% of torsional preloading. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  16. A new torsion pendulum for gravitational reference sensor technology development.

    Science.gov (United States)

    Ciani, Giacomo; Chilton, Andrew; Apple, Stephen; Olatunde, Taiwo; Aitken, Michael; Mueller, Guido; Conklin, John W

    2017-06-01

    We report on the design and sensitivity of a new torsion pendulum for measuring the performance of ultra-precise inertial sensors and for the development of associated technologies for space-based gravitational wave observatories and geodesy missions. The apparatus comprises a 1 m-long, 50 μm-diameter tungsten fiber that supports an inertial member inside a vacuum system. The inertial member is an aluminum crossbar with four hollow cubic test masses at each end. This structure converts the rotation of the torsion pendulum into translation of the test masses. Two test masses are enclosed in capacitive sensors which provide readout and actuation. These test masses are electrically insulated from the rest of the crossbar and their electrical charge is controlled by photoemission using fiber-coupled ultraviolet light emitting diodes. The capacitive readout measures the test mass displacement with a broadband sensitivity of 30 nm∕Hz and is complemented by a laser interferometer with a sensitivity of about 0.5 nm∕Hz. The performance of the pendulum, as determined by the measured residual torque noise and expressed in terms of equivalent force acting on a single test mass, is roughly 200 fN∕Hz around 2 mHz, which is about a factor of 20 above the thermal noise limit of the fiber.

  17. Machine for studying fatigue resistance of metals under conditions of separate and combined bending and torsional strain

    International Nuclear Information System (INIS)

    Belkin, M.Ya.; Rulev, V.I.; Filimonov, G.N.; Belkin, V.M.; Rud', Yu.M.

    1985-01-01

    A machine is described for fatigue tests of specimens with a diameter up to 50 mm under separate and combined action of cyclic torsion and bending. A design and operation of the tester are considered. Results of the experimental study on fatigue resistance of 38KhN3MFA steel specimens with pressed-on bushings are presented. Cyclic torsion stresses applied on cyclic bending eastresses are shown to decrse bending strength limit of the specimens the more, the highher is the relative level of the torsion stress

  18. Ocular torsional movements in normal humans.

    Science.gov (United States)

    Kushner, B J; Kraft, S

    1983-06-01

    We conducted three studies of compensatory ocular torsional movements in normal human subjects, using changes in the axis of astigmatism, afterimages, and direct observation with cinematography. Measurements of changes in the axis of astigmatism and the subjects' subjective perception of afterimages with a superimposed Maddox rod showed a partial compensatory intorsion on head tilt to the ipsilateral side and extorsion on head tilt to the contralateral side. Cinematography demonstrated that the eye lags behind the head in a slow rolling movement as the head is tilted. Periodic rotary movements in the direction of the head tilt partially correct the lag and result in a partial compensatory torsion. A fourth experiment excluded false torsion as an artifact in these studies.

  19. Torsional rigidity of submanifolds with controlled geometry

    DEFF Research Database (Denmark)

    Hurtado, Ana; Markvorsen, Steen; Palmer, Vicente

    2009-01-01

    We prove explicit upper and lower bounds for the torsional rigidity of extrinsic domains of submanifolds ^m$ with controlled radial mean curvature in ambient Riemannian manifolds ^n$ with a pole $ and with sectional curvatures bounded from above and from below, respectively. These bounds are given...... in terms of the torsional rigidities of corresponding Schwarz symmetrizations of the domains in warped product model spaces. Our main results are obtained using methods from previously established isoperimetric inequalities, as found in e.g. [MP4] and [MP5]. As in [MP4] we also characterize the geometry...... of those situations in which the bounds for the torsional rigidity are actually attained and study the behavior at infinity of the so-called geometric average of the mean exit time for Brownian motion....

  20. Torsion in patients with superior oblique palsies: dynamic torsion during saccades and changes in Listing's plane.

    Science.gov (United States)

    Steffen, Heimo; Straumann, Dominik S; Walker, Mark F; Miller, Neil R; Guyton, David L; Repka, Michael X; Zee, David S

    2008-05-01

    The purpose was to assess intra- and post-saccadic torsion in superior oblique palsy (SOP) patients and the effect of surgery on torsion. Eleven patients with a presumed congenital SOP and five with acquired SOP performed 10 degrees vertical saccades over a range of +/-20 degrees. Eye movements were recorded with dual search coils. Dynamic torsion was calculated by subtracting the expected change in torsion during the saccade (based upon static torsion before and after the saccade) from the maximum intrasaccadic torsion. Eight healthy subjects were controls. We also examined the effects of surgery on dynamic torsion and the orientation of Listing's plane in patients with congenital SOP who were operated on either by weakening of the inferior oblique muscle on the affected eye (n=5), by recession of the inferior rectus muscle on the normal eye (n=4) or by both procedures (n=2). Postoperative recordings were obtained at least 1 month after surgery. Patients with congenital and acquired SOP showed an increased dynamic extorsion, primarily during downward saccades. Following a recession of the inferior oblique muscle in congenital SOP patients, half showed significant decreases in extorsion (up to 1.0 degrees) during downward saccades by the affected eye. Following surgery all showed a temporal rotation of Listing's plane (up to 15 degrees for primary position). Patients with a SOP show a characteristic pattern of dynamic torsion during vertical saccades differing from normals. Recession of the inferior oblique muscle leads to rotation of Listing's plane in all congenital SOP patients and causes large changes in dynamic torsion in a subgroup of them, perhaps reflecting the heterogeneity of congenital SOP.

  1. The relationship between torsional rigidity and bending strength ...

    African Journals Online (AJOL)

    torsional buckling resistance of bending members and when members are subjected to torsional loads. This study was based on a series of laboratory experiments on actual sized timber with the focus and emphasis on mechanical properties and ...

  2. Torsional Behavior of Axonal Microtubule Bundles

    Science.gov (United States)

    Lazarus, Carole; Soheilypour, Mohammad; Mofrad, Mohammad R.K.

    2015-01-01

    Axonal microtubule (MT) bundles crosslinked by microtubule-associated protein (MAP) tau are responsible for vital biological functions such as maintaining mechanical integrity and shape of the axon as well as facilitating axonal transport. Breaking and twisting of MTs have been previously observed in damaged undulated axons. Such breaking and twisting of MTs is suggested to cause axonal swellings that lead to axonal degeneration, which is known as “diffuse axonal injury”. In particular, overstretching and torsion of axons can potentially damage the axonal cytoskeleton. Following our previous studies on mechanical response of axonal MT bundles under uniaxial tension and compression, this work seeks to characterize the mechanical behavior of MT bundles under pure torsion as well as a combination of torsional and tensile loads using a coarse-grained computational model. In the case of pure torsion, a competition between MAP tau tensile and MT bending energies is observed. After three turns, a transition occurs in the mechanical behavior of the bundle that is characterized by its diameter shrinkage. Furthermore, crosslink spacing is shown to considerably influence the mechanical response, with larger MAP tau spacing resulting in a higher rate of turns. Therefore, MAP tau crosslinking of MT filaments protects the bundle from excessive deformation. Simultaneous application of torsion and tension on MT bundles is shown to accelerate bundle failure, compared to pure tension experiments. MAP tau proteins fail in clusters of 10–100 elements located at the discontinuities or the ends of MT filaments. This failure occurs in a stepwise fashion, implying gradual accumulation of elastic tensile energy in crosslinks followed by rupture. Failure of large groups of interconnecting MAP tau proteins leads to detachment of MT filaments from the bundle near discontinuities. This study highlights the importance of torsional loading in axonal damage after traumatic brain injury

  3. A new model for analyzing nonlinear torsion behavior of concrete filled steel tube columns with rectangular section

    Science.gov (United States)

    Wang, Yuhang; Nie, Jianguo; Fan, Jiansheng

    2016-06-01

    An experimental study on concrete filled steel tube columns with rectangular section subjected to compressionflexure-torsion combined action has been carried out. The failure modes and load-deformation hysteretic relations were obtained. Based on the principles of classical material mechanics, the relations between the torsion curvature of the section and the shear strain of the fiber on the section were established. Then the strain distribution on the rectangular section of concrete filled steel tube columns subjected to torsion was analyzed. The three-dimensional refined finite element model was also built, in order to make the precision verification. The matrix forms of the relation between the torsion curvature of the section and the shear strain of the fiber on the section were derived, and introduced into the fiber beam model considering nonlinear torsion effect on the section. The comparison between test results and calculation results showed that the fiber beam model considering nonlinear torsion effect had high modeling efficiency and solution precision for predicting the torsion behavior of concrete filled steel tube columns with rectangular sections, and was suitable for analyzing the dynamic response of various structures subjected to the combined cyclic load caused by the earthquake load.

  4. On the geometrization of electromagnetism by torsion

    International Nuclear Information System (INIS)

    Fonseca Neto, J.B. da.

    1984-01-01

    The possibility of electromagnetism geometrization using an four dimension Cartan geometry is investigated. The Lagrangian density which presents dual invariance for dyons electrodynamics formulated in term of two potentials is constructed. This theory by association of two potentials with track and with torsion pseudo-track and of the field with torsion covariant divergent is described. The minimum coupling of particle gravitational field of scalar and spinorial fields with dyon geometry theory by the minimum coupling of these fields with Cartan geometry was obtained. (author)

  5. The torsion of the multicell sections

    Directory of Open Access Journals (Sweden)

    Marcel STERE

    2010-09-01

    Full Text Available The paper is focused on the stress analysis of thin-walled multicell sections subjected to pure torsion. The shear flow and stiffness characteristics of the cross section for torsion are given. Example: aircraft wing section. The theory for thin-walled closed sections used in this paper was developed by Bredt [3]. The shear flows obtained are used in the design of skins and interior webs, ribs and fasteners at skin splices, skin web junctions and the joints where the ribs meet the skin or webs.

  6. Disseminated peritoneal leiomyomatosis mimicking ovarian torsion

    Directory of Open Access Journals (Sweden)

    Chau-Yang Tyan

    2015-01-01

    Full Text Available The presentation of disseminated peritoneal leiomyomatosis (DPL can be misleading. Herein, we present the case of a 42-year-old nulliparous female who had previously undergone a total hysterectomy and presented with an acute abdomen. A presumptive diagnosis of ovarian torsion was made based on the clinical findings and an ultrasonographic examination. A diagnostic laparoscopy was performed immediately. DPL was subsequently diagnosed based on an intra-operative frozen section during surgical exploration and the final histopathologic examination. This case illustrates an atypical presentation of DPL mimicking ovarian torsion.

  7. High cycle torsional fatigue properties of 17-4PH stainless steel

    Directory of Open Access Journals (Sweden)

    K. Yanase

    2016-07-01

    Full Text Available Sensitivity to small defects under torsional fatigue loading condition is examined in the high cycle fatigue regime. Fatigue crack initiation and small crack growth behaviors were observed during fatigue testing and fractographic investigations were performed. The results are compared to the data obtained in the uniaxial fatigue tests, which allows the effect of biaxial stresses on the surface of material to be discussed. Finally, an approach for predicting the fatigue limit of 17-4PH stainless steel under torsional and tension-compression fatigue loadings is presented.

  8. Torsion of the fallopian tube: progression of sonographic features.

    Science.gov (United States)

    Richard, H M; Parsons, R B; Broadman, K F; Shapiro, R S; Yeh, H C

    1998-09-01

    Isolated torsion of the fallopian tube is a rare gynecologic condition that is difficult to diagnose preoperatively. We present the sonographic and CT findings over a 48-hour period in a case of isolated torsion of the fallopian tube. The radiologic features of isolated torsion have been described previously; however, to our knowledge, the progressive findings have not been previously reported.

  9. Testicular torsion: case report | Kuremu | East African Medical Journal

    African Journals Online (AJOL)

    This is a report of bilateral testicular torsion. The objective of the report is to highlight the serious implications of misdiagnosis of testicular torsion. Other than loss of the testis due to necrosis in unilateral torsion, immunological damage of the opposite testis occurs. Early, accurate diagnosis, and institution of the appropriate ...

  10. Damping in coupled bending and torsion - An experiment

    Science.gov (United States)

    Umland, Jeffrey W.; Inman, Daniel J.; Banks, H. T.

    1991-01-01

    Traditional experimental modal testing methods are used to determine the damping properties of a Euler-Bernoulli beam with offset inertial tip mass. Both viscous and strain rate damping models are considered in bending and in torsion. A partial differential equation model of the coupled system is used. Eigenfunctions are derived for the coupled system by using a Green's function approach to derive the approximate uncoupled eigenfunctions. These eigenfunctions are used in a decoupled fashion with experimental modal data to estimate the damping parameters of the coupled system. The experimental modal data were obtained from both free and impulse responses using a combined translational and rotational accelerometer.

  11. Comparison of Animal Discs Used in Disc Research to Human Lumbar Disc: Torsion Mechanics and Collagen Content

    Science.gov (United States)

    Showalter, Brent L.; Beckstein, Jesse C.; Martin, John T.; Beattie, Elizabeth E.; Orías, Alejandro A. Espinoza; Schaer, Thomas P.; Vresilovic, Edward J.; Elliott, Dawn M.

    2012-01-01

    Study Design Experimental measurement and normalization of in vitro disc torsion mechanics and collagen content for several animal species used in intervertebral disc research and comparing these to the human disc. Objective To aid in the selection of appropriate animal models for disc research by measuring torsional mechanical properties and collagen content. Summary of Background Data There is lack of data and variability in testing protocols for comparing animal and human disc torsion mechanics and collagen content. Methods Intervertebral disc torsion mechanics were measured and normalized by disc height and polar moment of inertia for 11 disc types in 8 mammalian species: the calf, pig, baboon, goat, sheep, rabbit, rat, and mouse lumbar, and cow, rat, and mouse caudal. Collagen content was measured and normalized by dry weight for the same discs except the rat and mouse. Collagen fiber stretch in torsion was calculated using an analytical model. Results Measured torsion parameters varied by several orders of magnitude across the different species. After geometric normalization, only the sheep and pig discs were statistically different from human. Fiber stretch was found to be highly dependent on the assumed initial fiber angle. The collagen content of the discs was similar, especially in the outer annulus where only the calf and goat discs were statistically different from human. Disc collagen content did not correlate with torsion mechanics. Conclusion Disc torsion mechanics are comparable to human lumbar discs in 9 of 11 disc types after normalization by geometry. The normalized torsion mechanics and collagen content of the multiple animal discs presented is useful for selecting and interpreting results for animal models of the disc. Structural composition of the disc, such as initial fiber angle, may explain the differences that were noted between species after geometric normalization. PMID:22333953

  12. Plant-based torsional actuator with memory

    Science.gov (United States)

    Nayomi Plaza; Samuel L. Zelinka; Don S. Stone; Joseph E. Jakes

    2013-01-01

    A bundle of a few loblolly pine (Pinus taeda) cells are moisture-activated torsional actuators that twist multiple revolutions per cm length in direct proportion to moisture content. The bundles generate 10 N m kg􀀀1 specific torque during both twisting and untwisting, which is higher than an electric motor. Additionally, the bundles exhibit a moisture-...

  13. FLEXURAL, TORSIONAL AND DISTORTIONAL BUCKLING OF ...

    African Journals Online (AJOL)

    neutral equilibrium of axially compressed single-cell box column with deformable cross-sections. The study ... FLEXURAL, TORSIONAL AND DISTORTIONAL BUCKLING OF SINGLE-CELL THIN-WALLED BOX COLUMNS cr. P : Critical buckling load. S: ... and v of a thin-walled closed structure in series form as follows: (1).

  14. Torsional Performance of Wind Turbine Blades

    DEFF Research Database (Denmark)

    Branner, Kim; Berring, Peter; Berggreen, Christian

    2007-01-01

    The present work investigates how well different finite element modeling techniques can predict bending and torsion behavior of a wind turbine blade. Two shell models are investigated. One model has element offsets and the other has the elements at the mid-thickness surfaces of the model. The las...

  15. Torsion of the gallbladder: a case report

    Directory of Open Access Journals (Sweden)

    Ijaz Samia

    2008-07-01

    Full Text Available Abstract Introduction Torsion of the gallbladder is a rare condition that most commonly affects the elderly. Pre-operative diagnosis is the exception rather than the rule. Any delay in treatment can be fatal as the gallbladder may rupture, leading to biliary peritonitis. Case presentation We present the case of an 80-year-old woman who was admitted with right upper quadrant pain initially thought to be secondary to acute cholecystitis. Subsequent ultrasound and computed tomography scans of the abdomen revealed signs suggestive of acute cholecystitis but neither modality detected any gallstones. As the patient's symptoms failed to resolve on conservative management, she was taken to theatre for an open cholecystectomy. Intra-operatively, the gallbladder had undergone complete torsion and appeared gangrenous. A routine cholecystectomy followed and she recovered from the operation without incident. Conclusion It is rare to diagnose torsion of the gallbladder pre-operatively despite advances in diagnostic imaging. However, this differential diagnosis should be borne in mind particularly in the elderly patient, without proven gallstones, who fails to improve on conservative management. An emergency cholecystectomy is indicated in the event of diagnosing torsion of the gallbladder to avert the potentially lethal sequelae of biliary peritonitis.

  16. Management and Outcome of Testicular Torsion

    African Journals Online (AJOL)

    multiruka1

    MSH, AFS, CGH: Research International East. Africa Limited. Coast Province General Hospital report 2015. 8. Lee SM, Huh JS, BaekM, et al. A Nationwide. Epidemiological Study of Testicular Torsion in. Korea. J Korean Med Sci. 2014; 29(12): 1684–1687. 9. Cattolica EV, Karol JB, Rankin KN, et al. High. Testicular Salvage ...

  17. Right paratesticular abscess mimicking neonatal testicular torsion ...

    African Journals Online (AJOL)

    U.O. Ezomike

    Right paratesticular abscess mimicking neonatal testicular torsion and caused by Proteus mirabilis. U.O. Ezomikea,∗. , M.A. Ituena, S.C. Ekpemoa, S.O. Ekenzeb a Department of Surgery, Federal Medical Centre Umuahia, Abia State, Nigeria b Sub-Department of Pediatric Surgery, University of Nigeria Teaching Hospital, ...

  18. Conformal deformation of Riemann space and torsion

    International Nuclear Information System (INIS)

    Pyzh, V.M.

    1981-01-01

    Method for investigating conformal deformations of Riemann spaces using torsion tensor, which permits to reduce the second ' order equations for Killing vectors to the system of the first order equations, is presented. The method is illustrated using conformal deformations of dimer sphere as an example. A possibility of its use when studying more complex deformations is discussed [ru

  19. Torsion of the gallbladder: a case report.

    Science.gov (United States)

    Ijaz, Samia; Sritharan, Kaji; Russell, Neil; Dar, Manzoor; Bhatti, Tahir; Ormiston, Michael

    2008-07-24

    Torsion of the gallbladder is a rare condition that most commonly affects the elderly. Pre-operative diagnosis is the exception rather than the rule. Any delay in treatment can be fatal as the gallbladder may rupture, leading to biliary peritonitis. We present the case of an 80-year-old woman who was admitted with right upper quadrant pain initially thought to be secondary to acute cholecystitis. Subsequent ultrasound and computed tomography scans of the abdomen revealed signs suggestive of acute cholecystitis but neither modality detected any gallstones. As the patient's symptoms failed to resolve on conservative management, she was taken to theatre for an open cholecystectomy. Intra-operatively, the gallbladder had undergone complete torsion and appeared gangrenous. A routine cholecystectomy followed and she recovered from the operation without incident. It is rare to diagnose torsion of the gallbladder pre-operatively despite advances in diagnostic imaging. However, this differential diagnosis should be borne in mind particularly in the elderly patient, without proven gallstones, who fails to improve on conservative management. An emergency cholecystectomy is indicated in the event of diagnosing torsion of the gallbladder to avert the potentially lethal sequelae of biliary peritonitis.

  20. The spectrum of axisymmetric torsional Alfven waves

    International Nuclear Information System (INIS)

    Sy, W.N.

    1977-03-01

    The spectrum of axisymmetric torsional Alfven waves propagating in a cylindrical, non-uniform, resistive plasma waveguide has been analysed by a method of singular perturbations. A simple condition has been derived which predicts whether the spectrum is continuous or discrete under given physical conditions. Application of this result to resolve an apparent discrepancy in experimental observations is briefly discussed. (Author)

  1. A torsional potential for graphene derived from fitting to DFT results

    Science.gov (United States)

    Chatzidakis, Georgios D.; Kalosakas, George; Fthenakis, Zacharias G.; Lathiotakis, Nektarios N.

    2018-01-01

    We present a simple torsional potential for graphene to accurately describe its out-of-plane deformations. The parameters of the potential are derived through appropriate fitting with suitable DFT calculations regarding the deformation energy of graphene sheets folded around two different folding axes, along an armchair or along a zig-zag direction. Removing the energetic contribution of bending angles, using a previously introduced angle bending potential, we isolate the purely torsional deformation energy, which is then fitted to simple torsional force fields. The presented out-of-plane torsional potential can accurately fit the deformation energy for relatively large torsional angles up to 0.5 rad. To test our proposed potential, we apply it to the problem of the vertical displacement of a single carbon atom out of the graphene plane and compare the obtained deformation energy with corresponding DFT calculations. The dependence of the deformation energy on the vertical displacement of the pulled carbon atom is indistinguishable in these two cases, for displacements up to about 0.5 Å. The presented potential is applicable to other sp2 carbon structures.

  2. Including Torsional Anharmonicity in Canonical and Microcanonical Reaction Path Calculations.

    Science.gov (United States)

    Zheng, Jingjing; Truhlar, Donald G

    2013-07-09

    We reformulate multistructural variational transition state theory by removing the approximation of calculating torsional anharmonicity only at stationary points. The multistructural method with torsional anharmonicity is applied to calculate the reaction-path free energy of the hydrogen abstraction from the carbon-1 position in isobutanol by OH radical. The torsional potential anharmonicity along the reaction path is taken into account by a coupled torsional potential. The calculations show that it can be critical to include torsional anharmonicity in searching for canonical and microcanonical variational transition states. The harmonic-oscillator approximation fails to yield reasonable free energy curves along the reaction path.

  3. [Conservative surgery of ovarian torsion in pediatrics].

    Science.gov (United States)

    Abad, P; Rigol, S; Ezzedine, H; Durán, C; Ortega, D; Martí, M; Pinyot, J

    2003-10-01

    The authors describe the case of two girls diagnosed of ovarian torsion secondary to a cyst. They were operated on by conservative ovarian therapy regardless the time of evolution and ovary macroscopical aspect. These 2 patients were 9 and 13 years old, with abdominal colic pain of 48 and 36 hours of evolution. The diagnosis by doppler sonography was ovarian torsion, with a 4 cms cyst in the right ovary in the first case and a 5 cms cyst in the left ovary in the second patient. Both patients were operated on. After untwisting the ovary, we instille warm saline solution to this ovary and, after waiting for 10 minutes, we resect the ovarian cyst and it recuperates partial and heterogeneous its pink colour. We advise to the family about the possibility of surgical reintervention if the ovary is not viable. After 10 and 12 days of surgical intervention, the Doppler sonography has confirmed the existence of ovary flow and the symmetry of affected ovary in comparation to the opposite on. At the present, both patients are asymptomatic, with exhaustive ultrasound controls. Ovarian torsion is the most frequent complication of ovarian tumours of pediatrics (3-16%) and this is a real emergency in gynecology. Traditionally, it has been recommended the exeresis of ovarian torsion. Regardless the blue aspect of isquemic ovary affected by torsion and the time of evolution, in our experience when there is a minimal possibility of ovarian viability, it is possible to follow a conservative therapy because the macroscopical aspect of the ovary is not necessarily related with the following evolution of the case.

  4. Distributed torsion sensor based on cascaded coaxial cable Fabry–Perot interferometers

    International Nuclear Information System (INIS)

    Cheng, Baokai; Zhu, Wenge; Hua, Liwei; Liu, Jie; Xiao, Hai; Li, Yurong; Nygaard, Runar

    2016-01-01

    Cascaded coaxial cable Fabry–Perot interferometers (FPI) are studied and demonstrated for distributed torsion measurement. Multiple weak reflectors are implemented on a coaxial cable so that any two consecutive reflectors can form a Fabry–Perot cavity. By fixing the cable sensor in a helical form on a shaft, the distributed torsion of the shaft can be measured by the cascaded Fabry–Perot cavities. A test on a single section shows that the sensor has a linear response with a sensitivity of 1.834 MHz (rad/m) −1 in the range of twisted rate from 0 to 8.726 rad m −1 . The distributed torsion sensing capability is useful in drilling process monitoring, structure health monitoring and machine failure detection. (paper)

  5. Vertical bending strength and torsional rigidity analysis of formula student car chassis

    Science.gov (United States)

    Hazimi, Hashfi; Ubaidillah, Setiyawan, Adi Eka Putra; Ramdhani, Hanief Cahya; Saputra, Murnanda Zaesy; Imaduddin, Fitrian

    2018-02-01

    Formula Society of Automotive Engineers (FSAE) is a competition for students to construct formula student car. One of an essential part of a formula student car is its chassis. Chassis is an internal vehicle frame which holds all another part of the vehicle and secures the driver. The team have to design their chassis and tests their design to achieve the best chassis that fulfill the regulation. This paper contains chassis design from Bengawan FSAE Team and some FEA tests to find out the Tensile Strength, Torsional Rigidity, and Von Misses Stress of Formula SAE car. Torsional rigidity was found by applying the static torsional test. The results from torsional rigidity test are a maximum deformation of 9.9512 mm with 1.7064 safety factor, and 35.935 MPa maximum Von Misses Stress. Moreover, then the result of the vertical bending strength test is 8.1214 mm max deformation with safety factor 4.2717, and 29.226 MPa maximum Von Misses Stress.

  6. A strain gradient plasticity theory with application to wire torsion

    KAUST Repository

    Liu, J. X.

    2014-06-05

    Based on the framework of the existing strain gradient plasticity theories, we have examined three kinds of relations for the plastic strain dependence of the material intrinsic length scale, and thus developed updated strain gradient plasticity versions with deformation-dependent characteristic length scales. Wire torsion test is taken as an example to assess existing and newly built constitutive equations. For torsion tests, with increasing plastic strain, a constant intrinsic length predicts too high a torque, while a decreasing intrinsic length scale can produce better predictions instead of the increasing one, different from some published observations. If the Taylor dislocation rule is written in the Nix-Gao form, the derived constitutive equations become singular when the hardening exponent gets close to zero, which seems questionable and calls for further experimental clarifications on the exact coupling of hardening due to statistically stored dislocations and geometrically necessary dislocations. Particularly, when comparing the present model with the mechanism-based strain gradient plasticity, the present model satisfies the reciprocity relation naturally and gives different predictions even under the same parameter setting. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  7. Distinguishing testicular torsion from torsion of the appendix testis by clinical features and signs in patients with acute scrotum

    Directory of Open Access Journals (Sweden)

    Fujita N

    2017-08-01

    Full Text Available Naoyuki Fujita,1 Mitsuhiro Tambo,1 Takatsugu Okegawa,1 Eiji Higashihara,2 Kikuo Nutahara1 1Department of Urology, 2Department of Autosomal Dominant Polycystic Kidney Disease (ADPKD Research, Kyorin University School of Medicine, Mitaka, Tokyo Purpose: Many physicians encounter confusion and difficulty in distinguishing testicular torsion (TT from torsion of the appendix testis (TAT in patients with acute scrotum because of the overlapping signs and symptoms. The objective of our study was to evaluate the clinical features and signs that can help distinguish TT from TAT. Patients and methods: We performed a retrospective study of patients with surgically confirmed TT and TAT at our institute from January 1990 to December 2013. Clinical findings, physical examination findings, climatic conditions, laboratory data, and color Doppler ultrasound (CDUS findings were compared between the TT and TAT groups. Results: Seventy patients were included in this study (49 with TT and 21 with TAT. Patients with TT were significantly older than those with TAT (p < 0.001. The ambient temperature at onset was significantly lower in patients with TT than in patients with TAT (p = 0.038. Testicular swelling, high-riding testes, onset during sleep, high leukocyte counts, and high creatine phosphokinase levels were significantly more common in patients with TT than with TAT (p = 0.021, 0.032, 0.006, 0.003, and 0.043, respectively. Multivariate analysis showed that age and onset during sleep were significant independent factors for detection of TT. Eight patients (16.3% underwent preoperative CDUS evaluation, and an absent or decreased blood signal in the involved testes was significantly correlated with the presence of TT (p = 0.018. Conclusion: In clinical features, age and onset during sleep might be helpful to distinguish TT from TAT. When supported by findings, urgent surgical exploration is warranted in patients with suspected TT based on symptoms and CDUS

  8. Mechanical stability of roll-to-roll printed solar cells under cyclic bending and torsion

    DEFF Research Database (Denmark)

    Finn, Mickey; Martens, Christian James; Zaretski, Aliaksandr V.

    2018-01-01

    The ability of printed organic solar cells (OSCs) to survive repeated mechanical deformation is critical to large-scale implementation. This paper reports an investigation into the mechanical stability of OSCs through bending and torsion testing of whole printed modules. Two types of modules...

  9. Torsion and transverse bending of cantilever plates

    Science.gov (United States)

    Reissner, Eric; Stein, Manuel

    1951-01-01

    The problem of combined bending and torsion of cantilever plates of variable thickness, such as might be considered for solid thin high-speed airplane or missile wings, is considered in this paper. The deflections of the plate are assumed to vary linearly across the chord; minimization of the potential energy by means of the calculus of variations then leads to two ordinary linear differential equations for the bending deflections and the twist of the plate. Because the cantilever is analyzed as a plate rather than as a beam, the effect of constraint against axial warping in torsion is inherently included. The application of this method to specific problems involving static deflection, vibration, and buckling of cantilever plates is presented. In the static-deflection problems, taper and sweep are considered.

  10. Torsional Tribological Behavior and Torsional Friction Model of Polytetrafluoroethylene against 1045 Steel.

    Science.gov (United States)

    Wang, Shibo; Niu, Chengchao

    2016-01-01

    In this work, the plane-on-plane torsional fretting tribological behavior of polytetrafluoroethylene (PTFE) was studied. A model of a rigid, flat-ended punch acting on an elastic half-space was built according to the experimental conditions. The results indicate that the shape of T-θ curves was influenced by both the torsional angle and the normal load. The torsion friction torque and wear rate of PTFE exponentially decreased when the torsion angle rose. The torsional torque increased from 0.025 N·m under a normal load of 43 N to 0.082 N·m under a normal load of 123 N. With sequentially increasing normal load, the value of torque was maintained. With rising normal load, the wear mass loss of PTFE disks was increased and the wear rate was decreased. Good agreement was found with the calculated torque according to the model and the experimental torque except for that under a normal load of 163 N. The difference under a normal load of 163 N was caused by the coefficient of friction. Usually the coefficient of friction of a polymer decreases with increasing normal load, whereas a constant coefficient of friction was applied in the model.

  11. Torsional Tribological Behavior and Torsional Friction Model of Polytetrafluoroethylene against 1045 Steel

    Science.gov (United States)

    Wang, Shibo; Niu, Chengchao

    2016-01-01

    In this work, the plane-on-plane torsional fretting tribological behavior of polytetrafluoroethylene (PTFE) was studied. A model of a rigid, flat-ended punch acting on an elastic half-space was built according to the experimental conditions. The results indicate that the shape of T–θ curves was influenced by both the torsional angle and the normal load. The torsion friction torque and wear rate of PTFE exponentially decreased when the torsion angle rose. The torsional torque increased from 0.025 N·m under a normal load of 43 N to 0.082 N·m under a normal load of 123 N. With sequentially increasing normal load, the value of torque was maintained. With rising normal load, the wear mass loss of PTFE disks was increased and the wear rate was decreased. Good agreement was found with the calculated torque according to the model and the experimental torque except for that under a normal load of 163 N. The difference under a normal load of 163 N was caused by the coefficient of friction. Usually the coefficient of friction of a polymer decreases with increasing normal load, whereas a constant coefficient of friction was applied in the model. PMID:26799324

  12. Torsional asymmetry in suspension bridge systems

    Czech Academy of Sciences Publication Activity Database

    Malík, Josef

    2015-01-01

    Roč. 60, č. 6 (2015), s. 677-701 ISSN 0862-7940 R&D Projects: GA MŠk ED2.1.00/03.0082 Institutional support: RVO:68145535 Keywords : suspension bridge * Hamilton principle * vertical and torsional oscillation * uniqueness * existence Subject RIV: BA - General Mathematics Impact factor: 0.507, year: 2015 http://link.springer.com/article/10.1007%2Fs10492-015-0117-3

  13. Torsion of a giant mesenteric lipoma

    Energy Technology Data Exchange (ETDEWEB)

    Wolko, Jonathan D.; Rosenfeld, David L.; Lazar, Michael J.; Underberg-Davis, Sharon J. [Department of Radiology, University of Medicine and Dentistry of New Jersey, Robert Wood Johnson Medical School, P.O. Box 19, New Brunswick, NJ 08903-0019 (United States)

    2003-01-01

    Mesenteric lipoma is a rare benign neoplastic condition that can grow to be very large and mimic other midgut fatty tumors. These benign tumors can cause various gastrointestinal symptoms such as obstruction and abdominal pain. We report the case of a 9-year-old boy who presented with a small bowel obstruction caused by torsion of a large mesenteric lipoma. This is an important but unusual tumor and should be considered in the differential of fatty lesions within the mesentery. (orig.)

  14. Electrostatically actuated torsional resonant sensors and switches

    KAUST Repository

    Younis, Mohammad I.

    2016-12-29

    Embodiments in accordance of a torsional resonant sensor disclosure is configured to actuate a beam structure using electrostatic actuation with an AC harmonic load (e.g., AC and DC voltage sources) that is activated upon detecting a particular agent having a mass above a predefined level. In various embodiments, the beam structure may be different types of resonant structures that is at least partially coated or layered with a selective material.

  15. Residual strain evolution in steel samples: tension versus torsion

    Science.gov (United States)

    Bunn, J. R.; Penumadu, D.; Hubbard, C. R.

    2010-06-01

    Torsion provides a unique opportunity to probe mechanical behavior of materials subjected to pure state of shear stress. In this research, identical steel alloy (12L14) hollow cylinder samples are subjected to predetermined amounts of plastic axial and shear strain such that their octahedral shear strain (an invariant) are identical for comparison. Measurements were made at the residual stress measuring facility at the High Flux Isotope Reactor in Oak Ridge (NRSF2), using a small gauge area in the direction of strain gradients (0.5 mm×0.5 mm) through the hollow cylinder wall thickness. These orthogonal strains are obtained for BCC Fe for three hkl’s. Three normal strains in the hoop, radial, and axial directions are obtained as a function of centroid position of the gauge volume through the 2 mm wall thickness. Significant differences in measured residual strains are noted between the torsion and the tension samples. The largest differences are found for the Fe (200) planes while the smallest differences are observed for the Fe (211) planes. This research demonstrates the need for a systematic study of residual strain as a function of applied stress path moving beyond tensile testing for solving real world problems.

  16. Spacetime thermodynamics in the presence of torsion

    Science.gov (United States)

    Dey, Ramit; Liberati, Stefano; Pranzetti, Daniele

    2017-12-01

    It was shown by Jacobson in 1995 that the Einstein equation can be derived as a local constitutive equation for an equilibrium spacetime thermodynamics. With the aim to understand if such thermodynamical description is an intrinsic property of gravitation, many attempts have been made so far to generalize this treatment to a broader class of gravitational theories. Here we consider the case of the Einstein-Cartan theory as a prototype of theories with nonpropagating torsion. In doing so, we study the properties of Killing horizons in the presence of torsion, establish the notion of local causal horizon in Riemann-Cartan spacetimes, and derive the generalized Raychaudhuri equation for these kinds of geometries. Then, starting with the entropy that can be associated to these local causal horizons, we derive the Einstein-Cartan equation by implementing the Clausius equation. We outline two ways of proceeding with the derivation depending on whether we take torsion as a geometric field or as a matter field. In both cases we need to add internal entropy production terms to the Clausius equation as the shear and twist cannot be taken to be 0 a priori for our setup. This fact implies the necessity of a nonequilibrium thermodynamics treatment for the local causal horizon. Furthermore, it implies that a nonzero twist at the horizon in general contributes to the Hartle-Hawking tidal heating for black holes with possible implications for future observations.

  17. Isolated Penile Torsion in Brothers: A Case Report

    Directory of Open Access Journals (Sweden)

    Metin Gunduz

    2012-04-01

    Full Text Available Penile torsion can be congenital and associated with hypospadias and chordee, or can be acquired after circumcision. The incidence of isolated neonatal penile torsion was 1.7 to 27% in the literature. The majority were between 10 and deg; and 20 and deg;. Generally, torsion was to the left in cases. The techniques for correction of penile torsion described in the literature are penile de-gloving and reattaching of skin, resection of Buck's fascia incising the base of the penis and removing angular ellipses of corporeal tissue with subsequent plication of tunica, and dorsal dartos flap rotation in severe cases. In conclusion, penile torsion may be familial. Therefore, brothers should be examined carefully. The degloving and realignment technique is successful in isolated penile torsion. [Arch Clin Exp Surg 2012; 1(2.000: 122-124

  18. Fast Torsional Artificial Muscles from NiTi Twisted Yarns.

    Science.gov (United States)

    Mirvakili, Seyed M; Hunter, Ian W

    2017-05-17

    Torsional artificial muscles made of multiwalled carbon nanotube/niobium nanowire yarns have shown remarkable torsional speed and gravimetric torque. The muscle structure consists of a twisted yarn with half of its length infiltrated with a stimuli-responsive guest material such as paraffin wax. The volumetric expansion of the guest material creates the torsional actuation in the yarn. In the present work, we show that this type of actuation is not unique to wax-infiltrated carbon multiwalled nanotube (MWCNT) or niobium nanowire yarns and that twisted yarn of NiTi alloy fibers also produces fast torsional actuation. By gold-plating half the length of a NiTi twisted yarn and Joule heating it, we achieved a fully reversible torsional actuation of up to 16°/mm with peak torsional speed of 10 500 rpm and gravimetric torque of 8 N·m/kg. These results favorably compare to those of MWCNTs and niobium nanowire yarns.

  19. Torsional stability of interference screws derived from bovine bone - a biomechanical study

    Directory of Open Access Journals (Sweden)

    Schmitt Jan

    2010-05-01

    Full Text Available Abstract Background In the present biomechanical study, the torsional stability of different interference screws, made of bovine bone, was tested. Interference screws derived from bovine bone are a possible biological alternative to conventional metallic or bioabsorbable polymer interference screws. Methods In the first part of the study we compared the torsional stability of self-made 8 mm Interference screws (BC and a commercial 8 mm interference screw (Tutofix®. Furthermore, we compared the torsional strength of BC screws with different diameters. For screwing in, a hexagon head and an octagon head were tested. Maximum breaking torques in polymethyl methacrylate resin were recorded by means of an electronic torque screw driver. In the second part of the study the tibial part of a bone-patellar tendon-bone graft was fixed in porcine test specimens using an 8 mm BC screw and the maximum insertion torques were recorded. Each interference screw type was tested 5 times. Results There was no statistically significant difference between the different 8 mm interference screws (p = 0.121. Pairwise comparisons did not reveal statistically significant differences, either. It was demonstrated for the BC screws, that a larger screw diameter significantly leads to higher torsional stability (p = 9.779 × 10-5. Pairwise comparisons showed a significantly lower torsional stability for the 7 mm BC screw than for the 8 mm BC screw (p = 0.0079 and the 9 mm BC screw (p = 0.0079. Statistically significant differences between the 8 mm and the 9 mm BC screw could not be found (p = 0.15. During screwing into the tibial graft channel of the porcine specimens, insertion torques between 0.5 Nm and 3.2 Nm were recorded. In one case the hexagon head of a BC screw broke off during the last turn. Conclusions The BC screws show comparable torsional stability to Tutofix® interference screws. As expected the torsional strength of the screws increases significantly with the

  20. Torsional stability of interference screws derived from bovine bone - a biomechanical study

    Science.gov (United States)

    2010-01-01

    Background In the present biomechanical study, the torsional stability of different interference screws, made of bovine bone, was tested. Interference screws derived from bovine bone are a possible biological alternative to conventional metallic or bioabsorbable polymer interference screws. Methods In the first part of the study we compared the torsional stability of self-made 8 mm Interference screws (BC) and a commercial 8 mm interference screw (Tutofix®). Furthermore, we compared the torsional strength of BC screws with different diameters. For screwing in, a hexagon head and an octagon head were tested. Maximum breaking torques in polymethyl methacrylate resin were recorded by means of an electronic torque screw driver. In the second part of the study the tibial part of a bone-patellar tendon-bone graft was fixed in porcine test specimens using an 8 mm BC screw and the maximum insertion torques were recorded. Each interference screw type was tested 5 times. Results There was no statistically significant difference between the different 8 mm interference screws (p = 0.121). Pairwise comparisons did not reveal statistically significant differences, either. It was demonstrated for the BC screws, that a larger screw diameter significantly leads to higher torsional stability (p = 9.779 × 10-5). Pairwise comparisons showed a significantly lower torsional stability for the 7 mm BC screw than for the 8 mm BC screw (p = 0.0079) and the 9 mm BC screw (p = 0.0079). Statistically significant differences between the 8 mm and the 9 mm BC screw could not be found (p = 0.15). During screwing into the tibial graft channel of the porcine specimens, insertion torques between 0.5 Nm and 3.2 Nm were recorded. In one case the hexagon head of a BC screw broke off during the last turn. Conclusions The BC screws show comparable torsional stability to Tutofix® interference screws. As expected the torsional strength of the screws increases significantly with the diameter. The safety

  1. Painless inter epididymal testicular torsion of the spermatic cord

    Directory of Open Access Journals (Sweden)

    Salomon V. Romano

    2007-02-01

    Full Text Available Inter epididymal testicular torsion of the spermatic cord is extremely rare and usually diagnosed at surgery. We present an unusual case of spermatic cord torsion in a 14-year-old male patient. It is important to highlight that the torsion occurred only on the distal half of the epididymis leaving the head untwisted and edematous. In addition, the fact that this condition was painless made this case extremely rare and motivated our presentation.

  2. Painless inter epididymal testicular torsion of the spermatic cord

    OpenAIRE

    Salomon V. Romano; Haime S. Hernan; Norberto Fredotovich

    2007-01-01

    Inter epididymal testicular torsion of the spermatic cord is extremely rare and usually diagnosed at surgery. We present an unusual case of spermatic cord torsion in a 14-year-old male patient. It is important to highlight that the torsion occurred only on the distal half of the epididymis leaving the head untwisted and edematous. In addition, the fact that this condition was painless made this case extremely rare and motivated our presentation.

  3. Secondary Torsion of Vermiform Appendix with Mucinous Cystadenoma

    OpenAIRE

    Maki Kitagawa; Tatsuya Kotani; Takeshi Yamano; Hideaki Tsurudome; Tomoya Hatakeyama; Yoshiaki Kuriu; Hiroshi Nishi; Masaharu Yabe

    2007-01-01

    Torsion of the vermiform appendix is a rare disorder, which causes abdominal symptoms indistinguishable from acute appendicitis. We report a case (a 34-year-old male) of secondary torsion of the vermiform appendix with mucinous cystadenoma. This case was characterized by mild inflammatory responses, pentazocine-resistant abdominal pain, and appendiceal tumor, which was not enhanced by the contrast medium on computed tomography presumably because of reduced blood flow by the torsion. These fin...

  4. In vivo acute changes in ATP and glucose concentrations in the testicles of prepubertal rats following unilateral torsion Estudo In vivo das alterações agudas das concentrações de ATP e glicose induzidas por torção testicular unilateral nos testículos ipsilaterais do rato pré-púbere

    Directory of Open Access Journals (Sweden)

    Sérgio Botelho Guimarães

    2002-04-01

    Full Text Available Objective: An experimental study has been conducted to investigate acute changes in testicular concentrations of ATP and glucose following one-hour unilateral 720° testicular torsion. Methods: Sixty prepubertal male Wistar rats were distributed into two groups. Group 1 (Ischemia animals (n=30 were divided into 5 subgroups (n=6. All animals were subjected to right testicular torsion of 720° lasting one hour followed by detorsion. Testicles were collected and arterial blood samples taken from abdominal aorta at the end of ischemic period and 0.5, 1, 6 and 24 hours following detorsion. The remaining rats (Group 2 - Sham operated were divided into 5 subgroups and submitted to a similar procedure but detorsion was performed immediately following torsion of the right testis. Results: ATP and glucose concentrations were significantly decreased (PObjetivo: Uma das causas mais freqüentes de dor escrotal intensa, de aparecimento súbito, em crianças e adolescentes, é a torção unilateral do testículo. O presente estudo tem como finalidade determinar as alterações agudas nas concentrações de ATP e glicose nos testículos submetidos à uma hora de isquemia induzida por torção testicular unilateral de 720°. Métodos: Sessenta ratos Wistar machos, pré-púberes, foram distribuídos em 2 grupos. O Grupo 1 (isquemia incluiu 30 animais aleatoriamente distribuídos em 5 subgrupos e submetidos à isquemia testicular por rotação do cordão espermático em torno de seu eixo (720º. Após 60 minutos a torção foi desfeita e em intervalos variáveis (30 minutos, 1 h, 6 h e 24 h procedeu-se à remoção dos testículos e coleta de amostra de sangue arterial. Os animais restantes (Grupo 2 - controle foram igualmente distribuídos e submetidos aos mesmos procedimentos mas a distorção do testículo foi efetuada imediatamente após a torção. Resultados: As concentrações de ATP e glicose foram significativamente menores (P<0,05 no grupo isquêmico em

  5. Isolated fallopian tube torsion during pregnancy: a case report.

    Science.gov (United States)

    Lee, D H; Park, Y K

    2015-01-01

    Isolated fallopian tube torsion is a rare pregnancy-related complication. It is frequently misdiagnosed as acute appendicitis or ovarian torsion owing to the lack of specific symptoms or signs. Here, the authors report a case of a 35-year-old primigravida at 30 weeks and six days of gestation who had presented with right isolated fallopian tube torsion and a history of right oophorectomy. The authors propose that isolated fallopian tube torsion should be included in the list of differential diagnosis when encountered with patients complaining of lower abdominal pain.

  6. Ultrasonographic features of prenatal testicular torsion: Case report

    Directory of Open Access Journals (Sweden)

    Elif Ağaçayak

    2013-01-01

    Full Text Available Although prenatal testicular torsion (PNTT is rarely observed,it is an important condition that can cause bilateralvanishing testis. Generally, PNTT cases observed asextravaginal torsion and treatment is emergency surgicalop-eration. In this article, 39 week presented a case diagnosedin the prenatal testicular torsion. PNTT diagnosiswas confirmed by Doppler ultrasonography and emergencysurgery was performed. Extravaginal left testiculartorsion gangrene and necrosis of the testis was observedin the operation. Left orchiectomy was performed andintrauter-ine ultrasonographic diagnosis was found to becorrect.Key words: Testicular torsion, prenatal diagnosis, features,ultrasonography

  7. Secondary Torsion of Vermiform Appendix with Mucinous Cystadenoma

    Directory of Open Access Journals (Sweden)

    Maki Kitagawa

    2007-06-01

    Full Text Available Torsion of the vermiform appendix is a rare disorder, which causes abdominal symptoms indistinguishable from acute appendicitis. We report a case (a 34-year-old male of secondary torsion of the vermiform appendix with mucinous cystadenoma. This case was characterized by mild inflammatory responses, pentazocine-resistant abdominal pain, and appendiceal tumor, which was not enhanced by the contrast medium on computed tomography presumably because of reduced blood flow by the torsion. These findings may be helpful for the preoperative diagnosis of secondary appendiceal torsion.

  8. Torsion of vermiform appendix with fecalith: a case report

    Science.gov (United States)

    Wani, Imtiaz; Kitagawa, Maki; Rather, Mudasir; Singh, Jang; Bhat, Gulam; Nazir, Mir

    2008-01-01

    Introduction Torsion of the vermiform appendix is a rare disorder, which causes abdominal symptoms indistinguishable from acute appendicitis and is found by chance during the laparotomy. Case presentation We report a case (a 76-year-old male) suffering of torsion of the vermiform appendix with fecalith. It was twisted 540 degrees in an anti-clockwise direction. Appendectomy was done. Conclusion Appendiceal torsion may be assocated with the presence of fecalith. This case is the oldest one among the patients with appendiceal torsion reported to literature. PMID:18577201

  9. Secondary Torsion of Vermiform Appendix with Mucinous Cystadenoma

    Science.gov (United States)

    Kitagawa, Maki; Kotani, Tatsuya; Yamano, Takeshi; Tsurudome, Hideaki; Hatakeyama, Tomoya; Kuriu, Yoshiaki; Nishi, Hiroshi; Yabe, Masaharu

    2007-01-01

    Torsion of the vermiform appendix is a rare disorder, which causes abdominal symptoms indistinguishable from acute appendicitis. We report a case (a 34-year-old male) of secondary torsion of the vermiform appendix with mucinous cystadenoma. This case was characterized by mild inflammatory responses, pentazocine-resistant abdominal pain, and appendiceal tumor, which was not enhanced by the contrast medium on computed tomography presumably because of reduced blood flow by the torsion. These findings may be helpful for the preoperative diagnosis of secondary appendiceal torsion. PMID:21487469

  10. Reliability and validity of measures of hammer toe deformity angle and tibial torsion.

    Science.gov (United States)

    Kwon, O Y; Tuttle, L J; Commean, P K; Mueller, M J

    2009-09-01

    Measures of second-fourth metatarsophalangeal joint (MTPJ) angle (indicator of hammer toe deformity) and clinical measures of tibial torsion have limited evidence for validity and reliability. The purposes of this study are to determine: (1) reliability of using a 3D digitizer (Metrecom) and computed tomography (CT) to measure MTPJ angle for toes 2-4; (2) reliability of goniometer, 3D digitizer, and CT to measure tibial torsion; (3) validity of MTPJ angle measures for toes 2-4 using goniometry and 3D digitizer compared to CT (gold standard) and (4) validity of tibial torsion measures using goniometry and 3D digitizer (Metrecom) compared to CT (gold standard). Twenty-nine subjects participated in this study. 27 feet with hammer toe deformity and 31 feet without hammer toe deformity were tested using standardized gonimetric, 3D digitizer and CT methods. ICCs (3,1), standard error of the measurement (SEM) values, and difference measures were used to characterize intrarater reliability. Pearson correlation coefficients and an analysis of variance were used to determine associations and differences between the measurement techniques. 3D digitizer and CT measures of MTPJ angle had high test-retest reliability (ICC = 0.95-0.96 and 0.98-0.99, respectively; SEM = 2.64-3.35 degrees and 1.42-1.47 degrees, respectively). Goniometry, 3D digitizer, and CT measures of tibial torsion had good test-retest reliability (ICC = 0.75, 0.85, and 0.98, respectively; SEM = 2.15 degrees, 1.74 degrees, and 0.72 degree, respectively). Both goniometric and 3D digitizer measures of MTPJ angle were highly correlated with CT measures of MTPJ angle (r = 0.84-0.90, r = 0.84-0.88, respectively) and tibial torsion (r = 0.72, r = 0.83). Goniometry, 3D digitizer, and CT measures were all different from each other for measures of hammer toe deformity (p Goniometry measures were different from CT measures and 3D digitizer measures of tibial torsion (p reliable. Goniometer and 3D digitizer measures of

  11. A rare cause of acute abdominal pain in children: Isolated tubal torsion; a case series

    Directory of Open Access Journals (Sweden)

    Yasemin Dere Gunal

    2017-06-01

    Full Text Available Isolated tubal torsion -a rare cause of acute abdomen in children-is usually difficult to diagnose because of non-specific findings. Surgical salphingectomy is required in delayed diagnosis in most cases. Three sexual inactive adolescents diagnosed in isolated tubal torsion (ITT were discussed for its diagnostic features and surgical management. Laboratory tests and radiological studies including ultrasonography (US, color doppler ultrasound were performed in all patients after evaluation for acute lower abdominal pain in emergency department and they underwent surgical intervention with laparotomy (n:2 and laparoscopy (n:1. One of the patients in this study had salpingectomy. Detorsion of the fallopian tube and cyst excision were performed in the remaining two patients who also had paratubal cysts. There was no recurrence in these patients during the follow-up for 3 and 2 years. The isolated tubal torsion should be kept in mind and early surgical management is essential in order to preserve fallopian tube because of its importance in fertility. Keywords: Fallopian tube, Torsion, Paratubal cyst, Adolescent, Acute abdomen

  12. The effect of acute superior oblique palsy on torsional optokinetic nystagmus in monkeys.

    Science.gov (United States)

    Shan, Xiaoyan; Tian, Jing; Ying, Howard S; Walker, Mark F; Guyton, David; Quaia, Christian; Optican, Lance M; Tamargo, Rafael J; Zee, David S

    2008-04-01

    To investigate the effects of acquired superior oblique palsy (SOP) and corrective strabismus surgery on torsional optokinetic nystagmus (tOKN) in monkeys. The trochlear nerve was severed intracranially in two rhesus monkeys (M1 and M2). For each monkey, more than 4 months after the SOP, the ipsilateral inferior oblique muscle was denervated and extirpated. For M2, 4 months later, the contralateral inferior rectus muscle was recessed by 2 mm. tOKN was elicited during monocular viewing of a rotating stimulus that was rear projected onto a screen 43.5 cm in front of the animal. Angular rotation of the stimulus about the center was 40 deg/s clockwise or counterclockwise. The main findings after trochlear nerve sectioning were (1) the amplitude and peak velocity of torsional quick and slow phases of the paretic eye was less than that in the normal eye for both intorsion and extorsion, and (2) the vertical motion of the paretic eye increased during both torsional slow and quick phases. After corrective inferior oblique surgery, both of these effects were even greater. Acquired SOP and corrective inferior oblique-weakening surgery create characteristic patterns of change in tOKN that reflect alterations in the dynamic properties of the extraocular muscles involved in eye torsion. tOKN also provides information complementary to that provided by the traditional Bielschowsky head-tilt test and potentially can help distinguish among different causes of vertical ocular misalignment.

  13. Premotor neurons encode torsional eye velocity during smooth-pursuit eye movements

    Science.gov (United States)

    Angelaki, Dora E.; Dickman, J. David

    2003-01-01

    Responses to horizontal and vertical ocular pursuit and head and body rotation in multiple planes were recorded in eye movement-sensitive neurons in the rostral vestibular nuclei (VN) of two rhesus monkeys. When tested during pursuit through primary eye position, the majority of the cells preferred either horizontal or vertical target motion. During pursuit of targets that moved horizontally at different vertical eccentricities or vertically at different horizontal eccentricities, eye angular velocity has been shown to include a torsional component the amplitude of which is proportional to half the gaze angle ("half-angle rule" of Listing's law). Approximately half of the neurons, the majority of which were characterized as "vertical" during pursuit through primary position, exhibited significant changes in their response gain and/or phase as a function of gaze eccentricity during pursuit, as if they were also sensitive to torsional eye velocity. Multiple linear regression analysis revealed a significant contribution of torsional eye movement sensitivity to the responsiveness of the cells. These findings suggest that many VN neurons encode three-dimensional angular velocity, rather than the two-dimensional derivative of eye position, during smooth-pursuit eye movements. Although no clear clustering of pursuit preferred-direction vectors along the semicircular canal axes was observed, the sensitivity of VN neurons to torsional eye movements might reflect a preservation of similar premotor coding of visual and vestibular-driven slow eye movements for both lateral-eyed and foveate species.

  14. Toward laboratory torsional spine magnetic reconnection

    Science.gov (United States)

    Chesny, David L.; Orange, N. Brice; Oluseyi, Hakeem M.; Valletta, David R.

    2017-12-01

    Magnetic reconnection is a fundamental energy conversion mechanism in nature. Major attempts to study this process in controlled settings on Earth have largely been limited to reproducing approximately two-dimensional (2-D) reconnection dynamics. Other experiments describing reconnection near three-dimensional null points are non-driven, and do not induce any of the 3-D modes of spine fan, torsional fan or torsional spine reconnection. In order to study these important 3-D modes observed in astrophysical plasmas (e.g. the solar atmosphere), laboratory set-ups must be designed to induce driven reconnection about an isolated magnetic null point. As such, we consider the limited range of fundamental resistive magnetohydrodynamic (MHD) and kinetic parameters of dynamic laboratory plasmas that are necessary to induce the torsional spine reconnection (TSR) mode characterized by a driven rotational slippage of field lines - a feature that has yet to be achieved in operational laboratory magnetic reconnection experiments. Leveraging existing reconnection models, we show that within a 3$ apparatus, TSR can be achieved in dense plasma regimes ( 24~\\text{m}-3$ ) in magnetic fields of -1~\\text{T}$ . We find that MHD and kinetic parameters predict reconnection in thin current sheets on time scales of . While these plasma regimes may not explicitly replicate the plasma parameters of observed astrophysical phenomena, studying the dynamics of the TSR mode within achievable set-ups signifies an important step in understanding the fundamentals of driven 3-D magnetic reconnection and the self-organization of current sheets. Explicit control of this reconnection mode may have implications for understanding particle acceleration in astrophysical environments, and may even have practical applications to fields such as spacecraft propulsion.

  15. The impact of clinical use on the torsional behavior of Reciproc and WaveOne instruments.

    Science.gov (United States)

    Magalhães, Rafael Rodrigues Soares de; Braga, Lígia Carolina Moreira; Pereira, Érika Sales Joviano; Peixoto, Isabella Faria da Cunha; Buono, Vicente Tadeu Lopes; Bahia, Maria Guiomar de Azevedo

    2016-01-01

    The aim of this study was to assess the influence of clinical use, in vivo, on the torsional behavior of Reciproc and WaveOne instruments considering the possibility that they degraded with use. Diameter at each millimeter, pitch length, and area at 3 mm from the tip were determined for both types of instruments. Twenty-four instruments, size 25, 0.08 taper, of each system were divided into two groups (n=12 each): Control Group (CG), in which new Reciproc (RC) and WaveOne Primary (WO) instruments were tested in torsion until rupture based on ISO 3630-1; and Experimental Group (EG), in which each new instrument was clinically used to clean and shape the root canals of one molar. After clinical use, the instruments were analyzed using optical and scanning electron microscopy and subsequently tested in torsion until fracture. Data were analyzed using one-way analysis of variance at a=.05. WO instruments showed significantly higher mean values of cross-sectional area A3 (P=0.000) and smaller pitch lengths than RC instruments with no statistically significant differences in the diameter at D3 (P=0.521). No significant differences in torsional resistance between the RC and WO new instruments (P=0.134) were found. The clinical use resulted in a tendency of reduction in the maximum torque of the analyzed instruments but no statistically significant difference was observed between them (P=0.327). During the preparation of the root canals, two fractured RC instruments and longitudinal and transversal cracks in RC and WO instruments were observed through SEM analysis. After clinical use, no statistically significant reduction in the torsional resistance was observed.

  16. Transverse posterior element fractures associated with torsion

    International Nuclear Information System (INIS)

    Abel, M.S.

    1989-01-01

    Six examples of a previously undescribed class of transverse vertebral element fractures are presented. These fractures differ from Chance and Smith fractures and their variants in the following respects: (1) the etiology is torsion and not flexion; (2) there is neither distraction of posterior ring fragments nor posterior ligament tears; (3) in contrast to Chance and Smith fractures, extension of the fracture into the vertebral body is absent or minimal; (4) the transverse process of the lumbar vertebra is avulsed at its base with a vertical fracture, not split horizontally. These fractures occur in cervical, lumbar, and sacral vertebrae in normal or compromised areas of the spine. (orig.)

  17. Possible role of torsion in gravitational theories

    International Nuclear Information System (INIS)

    Nieh, H.T.

    1983-01-01

    Torsion is of interest in an indirect way, in that it has the potential of being an important ingredient in a future successful quantum theory of gravitation. Einstein's theory of gravitation, despite its simplicity and elegance, and its successes in large-scale gravitational phenomena, can only be regarded as a macroscopic classical theory. It is a non-renormalizable quantum field theory, and, therefore, lacks the status of a good microscopic theory. It is the search for a successful quantum field theory of gravitation that poses as one of the great challenges to theoretical physics today. (Auth.)

  18. Stick-slip and Torsional Friction Factors in Inclined Wellbores

    Directory of Open Access Journals (Sweden)

    Aarsnes Ulf Jakob F.

    2018-01-01

    The model is shown to have a good match with the surface and downhole behavior of two deviated wellbores for depths ranging from 1500 to 3000 meters. In particular, the model replicates the amplitude and period of the oscillations, in both the topside torque and the downhole RPM, as caused by the along-string stick slip. It is further shown that by using the surface behavior of the drill-string during rotational startup, an estimate of the static and dynamic friction factors along the wellbore can be obtained, even during stick-slip oscillations, if axial tension in the drillstring is considered. This presents a possible method to estimate friction factors in the field when off-bottom stick slip is encountered, and points in the direction of avoiding stick slip through the design of an appropriate torsional start-up procedure without the need of an explicit friction test.

  19. A study of white etching crack formation by compression-torsion experiments

    OpenAIRE

    S. Averbeck; E. Kerscher

    2016-01-01

    In this study, an attempt was made to recreate the bearing damage phenomenon “White Etching Cracks” with a simplified testing setup. Rolling contact fatigue conditions were simulated with in-phase and out-ofphase cyclic compression-torsion experiments on 100Cr6 steel specimens. The results are compared in terms of microstructural change. Focused Ion Beam and metallographic analysis reveal that a fine-grained, white etching zone formed in the vicinity of the fatigue cracks of specimens tested ...

  20. Comparing endophenotypes in adult-onset primary torsion dystonia.

    LENUS (Irish Health Repository)

    Bradley, David

    2012-02-01

    Adult-onset primary torsion dystonia (AOPTD) has an autosomal dominant pattern of inheritance with markedly reduced penetrance; the genetic causes of most forms of AOPTD remain unknown. Endophenotypes, markers of sub-clinical gene carriage, may be of use detecting non-manifesting gene carriers in relatives of AOPTD patients. The aim of this study was to compare the utility of the spatial discrimination threshold (SDT) and temporal discrimination threshold (TDT) as potential endophenotypes in AOPTD. Data on other published candidate endophenotypes are also considered. Both SDT and TDT testing were performed in 24 AOPTD patients and 34 of their unaffected first degree relatives; results were compared with normal values from a control population. Of the 24 AOPTD patients 5 (21%) had abnormal SDTs and 20 (83%) had abnormal TDTs. Of the 34 first degree relatives 17 (50%) had abnormal SDTs and 14 (41%) had abnormal TDTs. Discordant results on SDT and TDT testing were found in 16 (67%) AOPTD patients and 21 (62%) first degree relatives. TDT testing has superior sensitivity compared to SDT testing in AOPTD patients; although false positive TDTs are recognised, the specificity of TDT testing in unaffected relatives is not determinable. The high level of discordance between the two tests probably relates methodological difficulties with SDT testing. The SDT is an unreliable AOPTD endophenotype; TDT testing fulfils criteria for a reliable endophenotype with a high sensitivity.

  1. Correlation of severity of penile torsion with type of hypospadias ...

    African Journals Online (AJOL)

    Objective: This study was carried out to evaluate the correlation between the severity of penile torsion on the one hand and the degree of ventral penile curvature and the type of hypospadias on the other. We also assessed the effectiveness of correction of chordee and torsion by penile degloving and mobilization of the ...

  2. Perinatal testicular torsion: literature review and local experience ...

    African Journals Online (AJOL)

    The prognosis in TUDT is guarded and contralateral fixation was not practiced, except in a 5-week-old infant. Early orchiopexy at 3–6 months is recommended. Cooperation between surgeons, neonatologists, and parents is mandatory to avoid time delay. Keywords: intrauterine testicular torsion, postnatal testicular torsion, ...

  3. Torsion of the Spermatic Cord: Is Bilateral Orchidopexy Really ...

    African Journals Online (AJOL)

    Aim: To evaluate the rationale for bilateral orchidopexy as treatment for unilateral torsion of the testis, by determining how frequently the contralateral testis shows an abnormal pathology in unilateral testicular torsion. Patients and Methods:This is a retrospective study using adult urology patients treated for both acute and ...

  4. experimental and analytical comparison of torsion, bending moment

    African Journals Online (AJOL)

    HOD

    by shear design. Less attention was paid in the past by reinforced concrete designers to these effects of torsion in reinforced concrete members. When torsion is encountered in reinforced ... and composite nature of the material and presence of cracks [2]. .... principles and some limited design equations for a generalized ...

  5. Penile Torsion: an Overlooked Anomaly with Distal Hypospadias

    African Journals Online (AJOL)

    HussamHassan

    with posterior hypospadias had associating penile torsion. Follow-up showed satisfactory correction of penile torsion in 3 out of 9 patients in group A; and in 8 out of ... using MillenMed DICOM viewer program for image analysis, based on the orientation of the urethral groove (meatus) relative to the vertical position (fig. B). P ...

  6. A Patient Presenting with Concurrent Testis Torsion and Epididymal Leiomyoma

    Directory of Open Access Journals (Sweden)

    E. Arpali

    2013-01-01

    Full Text Available Leiomyomas are the second most common tumors of epididymis. Patients with leiomyomas are sometimes misdiagnosed with testicular tumors. A Case of a patient with a scrotal mass presenting with testicular torsion is reported. Concurrent occurrence of testicular torsion and epididymal leiomyoma is an extremely rare condition.

  7. Torsion of right middle lobe after a right upper lobectomy

    Directory of Open Access Journals (Sweden)

    Chen Tung-Ying

    2009-04-01

    Full Text Available Abstract Lobar torsion after lung resection is a quite rare complication. A 50-year-old woman presented typical features on chest radiographs and CT(computed tomography scan of lobar torsion after a right upper lobectomy. After emergency lobectomy of right middle lobe, the patient recovered well and discharged 10 days after the second operation.

  8. Mechanical origins of rightward torsion in early chick brain development

    Science.gov (United States)

    Chen, Zi; Guo, Qiaohang; Dai, Eric; Taber, Larry

    2015-03-01

    During early development, the neural tube of the chick embryo undergoes a combination of progressive ventral bending and rightward torsion. This torsional deformation is one of the major organ-level left-right asymmetry events in development. Previous studies suggested that bending is mainly due to differential growth, however, the mechanism for torsion remains poorly understood. Since the heart almost always loops rightwards that the brain twists, researchers have speculated that heart looping affects the direction of brain torsion. However, direct evidence is lacking, nor is the mechanical origin of such torsion understood. In our study, experimental perturbations show that the bending and torsional deformations in the brain are coupled and that the vitelline membrane applies an external load necessary for torsion to occur. Moreover, the asymmetry of the looping heart gives rise to the chirality of the twisted brain. A computational model and a 3D printed physical model are employed to help interpret these findings. Our work clarifies the mechanical origins of brain torsion and the associated left-right asymmetry, and further reveals that the asymmetric development in one organ can induce the asymmetry of another developing organ through mechanics, reminiscent of D'Arcy Thompson's view of biological form as ``diagram of forces''. Z.C. is supported by the Society in Science - Branco Weiss fellowship, administered by ETH Zurich. L.A.T acknowledges the support from NIH Grants R01 GM075200 and R01 NS070918.

  9. Torsion of the Spermatic Cord: An Exemplary Early Presentation ...

    African Journals Online (AJOL)

    ... still the norm. In the index patient, the presentation time was very short. In our environment, patients with torsion of the spermatic cord can present early and be operated promptly if we can provide public health education, mobile phones, commercial taxis, and good road networks. Keywords: Spermatic cord, testis, torsion ...

  10. Effect of irregularity on torsional surface waves in an initially ...

    Indian Academy of Sciences (India)

    Effect of irregularity on torsional surface waves in an initially stressed anisotropic porous layer sandwiched between homogeneous and non-homogeneous half- ... Torsional wave; anisotropy; initial stress; irregularity; non-homogeneity ... Department of Applied Mathematics, Indian School of Mines, Dhanbad 826 004, India.

  11. Case series on testicular torsion: an educational emergency for sub ...

    African Journals Online (AJOL)

    305 records ... Testicular torsion remains a common surgical emergency of adolescent males presenting with sudden onset of intense scrotal pain in Africa. While the magnitude of testicular torsion is not known it has been identified as a cause of male infertility. Testicular loss in Africa is directly related to delay in surgery and ...

  12. Severe congenital penile torsion with anterior urethral diverticulum ...

    African Journals Online (AJOL)

    On examination, he was found to be a case of severe congenital penile torsion with diversion and rotation of median raphae in a counterclockwise fashion upto the midline dorsally confirming 180◦ torsion. During voiding, there was appearance of a swelling in distal penile region with passage of urinary drops while ...

  13. Intermittent Testicular Torsion | Obi | Nigerian Journal of Clinical ...

    African Journals Online (AJOL)

    Methods: Clinical and demographic data of all patients treated for intermittent testicular torsion from January 2007 to June 2015 were prospectively collected in a pro forma and analyzed. A diagnosis of intermittent torsion was made on the basis of recurrent scrotal pain, presence of abnormal testicular lie in otherwise normal ...

  14. Protective effects of udenafil citrate, piracetam and dexmedetomidine treatment on testicular torsion/detorsion-induced ischaemia/reperfusion injury in rats.

    Science.gov (United States)

    Tuglu, D; Yuvanc, E; Ozan, T; Bal, F; Yilmaz, E; Atasoy, P; Kisa, U; Batislam, E

    2016-08-01

    The aim of this study was to investigate the antioxidant properties of udenafil citrate (1.4 mg kg(-1) -2.8 mg kg(-1) ), dexmedetomidine 25 μg kg(-1) and piracetam 200 mg kg(-1) administered on ipsilateral/contralateral testes after ischaemia in a rat model of testicular torsion/detorsion (T/D) and define its protective effect histologically. Fifty-six Wistar albino rats were included and randomly assigned into 6 groups. No intervention was performed in control group (Group 1, n = 8) and in torsion/detorsion group, (Group 2, n = 8). Udenafil 1.4 mg kg(-1) was given to torsion/detorsion group (Group 3, n = 10), udenafil 2.8 mg kg(-1) was given to torsion/detorsion group (Group 4, n = 10), piracetam 200 mg kg(-1) was given to torsion/detorsion group (Group 5, n = 10) and dexmedetomidine 25 μg kg(-1) was given to torsion/detorsion group (Group 6, n = 10) intraperitoneally after 60 mins of testicular torsion. Biochemical and histopathological testicular injury were evaluated. When the tissue was examined by TOS values, Group 3, Group 4 and Group 5 were significantly lower than Group 2. In contrary Group 6 values were significantly higher than Group 2. The increasing doses of udenafil demonstrated antioxidant properties on the testis tissue and histopathological that protects the testicles. © 2015 Blackwell Verlag GmbH.

  15. The efficacy of rotational control designs in promoting torsional stability of hip fracture fixation.

    Science.gov (United States)

    Gosiewski, J D; Holsgrove, T P; Gill, H S

    2017-05-01

    Fractures of the proximal femur are a common clinical problem, and a number of orthopaedic devices are available for the treatment of such fractures. The objective of this study was to assess the rotational stability, a common failure predictor, of three different rotational control design philosophies: a screw, a helical blade and a deployable crucifix. Devices were compared in terms of the mechanical work (W) required to rotate the implant by 6° in a bone substitute material. The substitute material used was Sawbones polyurethane foam of three different densities (0.08 g/cm 3 , 0.16 g/cm 3 and 0.24 g/cm 3 ). Each torsion test comprised a steady ramp of 1°/minute up to an angular displacement of 10°. The deployable crucifix design (X-Bolt), was more torsionally stable, compared to both the dynamic hip screw (DHS, p = 0.008) and helical blade (DHS Blade, p= 0.008) designs in bone substitute material representative of osteoporotic bone (0.16 g/cm 3 polyurethane foam). In 0.08 g/cm 3 density substrate, the crucifix design (X-Bolt) had a higher resistance to torsion than the screw (DHS, p = 0.008). There were no significant differences (p = 0.101) between the implants in 0.24 g/cm 3 density bone substitute. Our findings indicate that the clinical standard proximal fracture fixator design, the screw (DHS), was the least effective at resisting torsional load, and a novel crucifix design (X-Bolt), was the most effective design in resisting torsional load in bone substitute material with density representative of osteoporotic bone. At other densities the torsional stability was also higher for the X-Bolt, although not consistently significant by statistical analysis. Cite this article : J. D. Gosiewski, T. P. Holsgrove, H. S. Gill. The efficacy of rotational control designs in promoting torsional stability of hip fracture fixation. Bone Joint Res 2017;6:270-276. DOI: 10.1302/2046-3758.65.BJR-2017-0287.R1. © 2017 Gosiewski et al.

  16. Turbulence Modeling of Torsional Couette Flows

    Directory of Open Access Journals (Sweden)

    Sofia Haddadi

    2008-01-01

    Full Text Available The present study considers the numerical modeling of the turbulent flow inside a rotor-stator cavity subjected or not to a superimposed throughflow. Extensive numerical predictions based on one-point statistical modeling using a low Reynolds number second-order full stress transport closure (RSM model are performed mainly in the case of turbulent flows with merged boundary layers known as turbulent torsional Couette flows and belonging to regime III of Daily and Nece (1960. The RSM model has already shown its capability of predicting accurately the mean and turbulent fields in various rotating disk configurations (Poncet, 2005; Poncet et al., 2005, 2007, 2008. For the first time, a detailed mapping of the hydrodynamic flow over a wide range of rotational Reynolds numbers (180 000≤Re≤10 000 000, aspect ratios of the cavity (0.02≤G≤0.05, and flow rate coefficients (−10000≤Cw≤10000 is here provided in the turbulent torsional Couette flow regime.

  17. Lung lobe torsion in seven juvenile dogs.

    Science.gov (United States)

    Latimer, Christian R; Lux, Cassie N; Sutton, Jessie S; Culp, William T N

    2017-12-15

    CASE DESCRIPTION 7 juvenile (< 12 months old) dogs with lung lobe torsion were evaluated. CLINICAL FINDINGS All patients were male; breeds included Pug (n = 5), Chinese Shar-Pei (1), and Bullmastiff (1). Dyspnea and lethargy were the most common initial complaints, with a duration of clinical signs ranging from 1 to 10 days. A CBC showed leukocytosis and neutrophilia in all dogs. Anemia was present in 6 dogs, 2 of which received packed RBC transfusions. The diagnosis was made on the basis of results of thoracic radiography, CT, ultrasonography, or a combination of modalities. The left cranial lung lobe was most commonly affected (n = 4), followed by the right middle lung lobe (2) and the right cranial lung lobe (1). TREATMENT AND OUTCOME A lateral intercostal thoracotomy with lobectomy of the affected lobe was performed in all patients. All dogs survived to be discharged between 1 and 2 days postoperatively. Six of 7 owners contacted for follow-up information 7 to 170 months after discharge reported satisfaction with the treatment and no apparent signs of recurrence of disease. CLINICAL RELEVANCE The juvenile patients of this report were successfully treated surgically with no apparent complications. Clinicians should be aware of the possibility of lung lobe torsion when evaluating young dogs with clinical signs related to the respiratory system, including those with vague signs, to avoid undue delays in treatment.

  18. The Reidemeister torsion of 3-manifolds

    CERN Document Server

    Nicolaescu, Liviu I

    2003-01-01

    This is a state-of-the-art introduction to the work of Franz Reidemeister, Meng Taubes, Turaev, and the author on the concept of torsion and its generalizations. Torsion is the oldest topological (but not with respect to homotopy) invariant that in its almost eight decades of existence has been at the center of many important and surprising discoveries. During the past decade, in the work of Vladimir Turaev, new points of view have emerged, which turned out to be the "right ones" as far as gauge theory is concerned. The book features mostly the new aspects of this venerable concept. The theoretical foundations of this subject are presented in a style accessible to those, who wish to learn and understand the main ideas of the theory. Particular emphasis is upon the many and rather diverse concrete examples and techniques which capture the subleties of the theory better than any abstract general result. Many of these examples and techniques never appeared in print before, and their choice is often justified by ...

  19. Krukenberg Tumor: A Rare Cause of Ovarian Torsion

    Directory of Open Access Journals (Sweden)

    Sameer Sandhu

    2012-01-01

    Full Text Available Ovarian torsion is the fifth most common gynecological surgical emergency. Ovarian torsion is usually associated with a cyst or a tumor, which is typically benign. The most common is mature cystic teratoma. We report the case of a 43-year-old woman who came to the Emergency Department with rare acute presentation of bilateral Krukenberg tumors, due to unilateral ovarian torsion. In this case report, we highlight the specific computed tomography (CT features of ovarian torsion and demonstrate the unique radiological findings on CT imaging. Metastasis to the ovary is not rare and 5 to 10% of all ovarian malignancies are metastatic. The stomach is the common primary site in most Krukenberg tumors (70%; an acute presentation of metastatic Krukenberg tumors with ovarian torsion is rare and not previously reported in radiology literature.

  20. Physics of detecting torsion and placing limits on its effects

    International Nuclear Information System (INIS)

    Stoeger, W.R.

    1985-01-01

    The essential principles of torsion-detection physics are presented, and an evaluation is conducted of several conceivable types of experiments and observations for actually detecting torsion fields, reemphasizing also the evident impossibility of successfully searching for its manifestations among cosmological relics. In particular, a polarized body, with net intrinsic (fundamental-particle) spin, is essential for detecting a torsion field. One which possesses only orbital angular momentum - rotation - or an unpolarized intrinsic spin density will not feel torsion. The fundamental problem in searching for such fields is the extremely small basic unit of the coupling or interaction energy between the torsion field and spin. The best way of maximizing the total interaction energy is to increase the spin density of the source sigma-s and at the same time the spin number SD of the detector. 15 references

  1. Anterior Lumbar Interbody Fusion Integrated Screw Cages: Intrinsic Load Generation, Subsidence, and Torsional Stability.

    Science.gov (United States)

    Assem, Yusuf; Pelletier, Matthew H; Mobbs, Ralph J; Phan, Kevin; Walsh, William R

    2017-05-01

    To perform a repeatable idealized in vitro model to evaluate the effects of key design features and integrated screw fixation on unloaded surface engagement, subsidence, and torsional stability. We evaluated four different stand-alone anterior lumbar interbody fusion (ALIF) cages with two, three, and four screw designs. Polyurethane (saw-bone) foam blocks were used to simulate the vertebral bone. Fuji Film was used to measure the contact footprint, average pressure, and load generated by fixating the cages with screws. Subsidence was tested by axially loading the constructs at 10 N/s to 400 N and torsional load was applied +/-1 Nm for 10 cycles to assess stability. Outcome measures included total subsidence and maximal torsional angle range. Cages 1, 2, and 4 were symmetrical and produced similar results in terms of contact footprint, average pressure, and load. The addition of integrated screws into the cage-bone block construct demonstrated a clear trend towards decreased subsidence. Cage 2 with surface titanium angled ridges and a keel produced the greatest subsidence with and without screws, significantly more than all other cages ( P < 0.05). Angular rotation was not significantly affected by the addition of screws ( P < 0.066). A statistically significant correlation existed between subsidence and reduced angular rotation across all cage constructs ( P = 0.018). Each stand-alone cage featured unique surface characteristics, which resulted in differing cage-foam interface engagement, influencing the subsidence and torsional angle. Increased subsidence significantly reduced the torsional angle across all cage constructs. © 2017 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

  2. Lateral-Torsional Buckling Instability Caused by Individuals Walking on Wood Composite I-Joists

    Science.gov (United States)

    Villasenor Aguilar, Jose Maria

    Recent research has shown that a significant number of the falls from elevation occur when laborers are working on unfinished structures. Workers walking on wood I-joists on roofs and floors are prone to fall hazards. Wood I-joists have been replacing dimension lumber for many floor systems and a substantial number of roof systems in light-frame construction. Wood I-joists are designed to resist axial stresses on the flanges and shear stresses on the web while minimizing material used. However, wood I-joists have poor resistance to applied lateral and torsional loads and are susceptible to lateral-torsional buckling instability. Workers walking on unbraced or partially braced wood I-joists can induce axial and lateral forces as well as twist. Experimental testing demonstrated that workers cause lateral-torsional buckling instability in wood I-joists. However, no research was found related to the lateral-torsional buckling instability induced by individuals walking on the wood I-joists. Furthermore, no research was found considering the effects of the supported end conditions and partial bracing in the lateral-torsional buckling instability of wood I-joists. The goal of this research was to derive mathematical models to predict the dynamic lateral-torsional buckling instability of wood composite I-joists loaded by individuals walking considering different supported end conditions and bracing system configurations. The dynamic lateral-torsional buckling instability was analyzed by linearly combining the static lateral-torsional buckling instability with the lateral bending motion of the wood Ijoists. Mathematical models were derived to calculate the static critical loads for the simply supported end condition and four wood I-joist hanger supported end conditions. Additionally, mathematical models were derived to calculate the dynamic maximum lateral displacements and positions of the individual walking on the wood Ijoists for the same five different supported end

  3. Development of a new biaxial testing system for generating forming limit diagrams for sheet metals under hot stamping conditions

    OpenAIRE

    Shao, Z; Li, N; Lin, J; Dean, TA

    2016-01-01

    Conventional experimental approaches used to generate forming limit diagrams (FLDs) for sheet metals at different linear strain paths are not applicable to hot stamping and cold die quenching processes because cooling occurs prior to deformation and consistent values of heating rate, cooling rate, deformation temperature and strain rate are not easy to obtain. A novel biaxial testing system for use in a Gleeble testing machine has been adopted to generate forming limits of sheet metals, inclu...

  4. Burden and seasonality of testicular torsion in tropical Africa: Analysis of incident cases in a Nigerian community

    Directory of Open Access Journals (Sweden)

    Jibril O. Bello

    2018-03-01

    Full Text Available Introduction: Children, adolescents and young adults in tropical Africa occasionally presents to the emergency department with testicular torsion. However, no estimates of the burden of the condition is available and there is also sparse evidence of a seasonal variation in incidence. Objective: To determine the incidence and seasonality of the condition in a Nigerian community. Subjects and methods: A retrospective review of incident cases of testicular torsion occurring in a typical tropical sub-Saharan African community between January 2011 and December 2016 was performed. Incidence rates were calculated and trend analysis performed to evaluate for seasonality. Results: Twenty-three patients were seen during the study period and the average annual incidence of testicular torsion among ‘at risk’ males (<40 years was 2.7/100,000. Testicular salvage rate was 81%. Cases occurred 91% higher than average during the cold season (November to January. Trend analysis revealed a significant seasonal difference in the number of cases seen (p = 0.045 and Post Hoc tests (Tukey further showed that this is attributable to the seasonal difference between the cold season and the warmer early rains period (p = 0.036. Conclusion: The burden of testicular torsion found in the studied tropical sub-Saharan community is comparable to other regions of the world and seasonal variation in incidence does occur with a significant increase in cases during the cold season. Keywords: Testicular torsion, Seasonality, Disease burden, Orchiopexy, Orchiectomy

  5. A dedicated torsion balance to detect neutrinos by coherent scattering on high Debye temperature monocrystals

    Energy Technology Data Exchange (ETDEWEB)

    Cruceru, I; Nicolescu, G [National Institute of Research and Development for Physics and Nuclear Engineering ' Horia - Hulubei' , PO Box MG - 6, 077125 Magurele (Romania); Duliu, O G [University of Bucharest, Department of Atomic and Nuclear Physics, PO Box MG-II, 077125 Magurele (Romania)

    2008-11-01

    Coherent scattering of neutrinos on high Debye temperature monocrystals represent an alternative to detect solar as well as other high flux neutrino sources such as nuclear reactors or nuclear tests. Therefore, the possibility of detecting neutrinos by using sapphire monocrystals is presented and analyzed. Preliminary evaluations showed that 1 MeV neutrinos with a fluency density of 10{sup 12} cm{sup -1} s{sup -1} could interact with a 100 g sapphire monocrystal with a force of about 10{sup -6} dyne, value measurable with a high sensitivity torsion balance. For this reason a torsion balance provided with 1 m length molybdenum or tungsten wire and an optical autocollimator able to measure small rotation angles of about 0.1 seconds of arc was designed, constructed and now is under preliminary tests. Both theoretical and practical implications of such kind of detector are presented and discussed.

  6. Ratcheting of 316L stainless steel thin wire under tension-torsion loading

    Directory of Open Access Journals (Sweden)

    Sichao Fu

    2016-10-01

    Full Text Available A series of cyclic tension-torsion tests under symmetric shear strain and asymmetric axial stress control in various loading paths are conducted on 100 μm-diameter 316L steel wires applying a micro tensiontorsion fatigue testing apparatus. The ratcheting strain of the thin wire increases with increasing axial mean stress and decreases in a sequence of linear, rhombic and circular paths. The macro-scale based cyclic plastic constitutive models with kinematic hardening rules of the Ohno-Wang (OW and the Chen-Jiao-Kim (C-J-K are evaluated for the thin wire. Comparing with the O-W, the C-J-K predicts more accurately under high axial stress. While the loading path effects on ratcheting for wire specimens are basically simulated, the macro-based models tend to under-estimate the effect of phase difference between axial and torsional loadings and the ratcheting evolution in the initial 50 cycles

  7. Torsional changes in surgery for A-V phenomena.

    Science.gov (United States)

    Sharma, P; Halder, M; Prakash, P

    1997-03-01

    The role of torsion in the aetiopathogenesis of A-V phenomena has not been sufficiently emphasized. The success of vertical displacement of horizontal recti in correction of A or V has not been attributed to torsional changes. To evaluate this aspect, 21 cases of A or V phenomena were subjected to monocular recession-resection procedure with vertical shifting. Preoperative and postoperative torsional changes were evaluated on synoptophore (subjective torsion), and confirmed by fundus photography (objective torsion). Intorsion with A phenomenon was seen preoperatively in 5 of 8 cases which increased after surgery and was seen postoperatively in the other 3 cases also. Extorsion was observed in 5 of 13 cases pre operatively in 'V' phenomenon, but the changes in extorsion after surgery were less dramatic than those in intorsion. The oblique overactions were reduced in cases where they were present. Correction of A-V phenomena by torsion induced by vertical shifting of horizontal recti muscles is proposed, highlighting the role of torsion in A-V phenomena.

  8. Torsional changes in surgery for A-V phenomena

    Directory of Open Access Journals (Sweden)

    Sharma Pradeep

    1997-01-01

    Full Text Available The role of torsion in the aetiopathogenesis of A-V phenomena has not been sufficiently emphasized. The success of vertical displacement of horizontal recti in correction of A or V has not been attributed to torsional changes. To evaluate this aspect, 21 cases of A or V phenomena were subjected to monocular recession-resection procedure with vertical shifting. Preoperative and postoperative torsional changes were evaluated on synoptophore (subjective torsion, and confirmed by fundus photography (objective torsion. Intorsion with A phenomenon was seen preoperatively in 5 of 8 cases which increased after surgery and was seen postoperatively in the other 3 cases also. Extorsion was observed in 5 of 13 cases pre operatively in ′V′ phenomenon, but the changes in extorsion after surgery were less dramatic than those in intorsion. The oblique overactions were reduced in cases where they were present. Correction of A-V phenomena by torsion induced by vertical shifting of horizontal recti muscles is proposed, highlighting the role of torsion in A-V phenomena.

  9. Torsion based universal MEMS logic device

    KAUST Repository

    Ilyas, Saad

    2015-10-28

    In this work we demonstrate torsion based complementary MEMS logic device, which is capable, of performing INVERTER, AND, NAND, NOR, and OR gates using one physical structure within an operating range of 0-10 volts. It can also perform XOR and XNOR with one access inverter using the same structure with different electrical interconnects. The paper presents modeling, fabrication and experimental calculations of various performance features of the device including lifetime, power consumption and resonance frequency. The fabricated device is 535 μm by 150 μm with a gap of 1.92 μm and a resonant frequency of 6.51 kHz. The device is capable of performing the switching operation with a frequency of 1 kHz.

  10. Combined bending-torsion fatigue reliability. III

    Science.gov (United States)

    Kececioglu, D.; Chester, L. B.; Nolf, C. F., Jr.

    1975-01-01

    Results generated by three, unique fatigue reliability research machines which can apply reversed bending loads combined with steady torque are presented. AISI 4340 steel, grooved specimens with a stress concentration factor of 1.42 and 2.34, and Rockwell C hardness of 35/40 were subjected to various combinations of these loads and cycled to failure. The generated cycles-to-failure and stress-to-failure data are statistically analyzed to develop distributional S-N and Goodman diagrams. Various failure theories are investigated to determine which one represents the data best. The effects of the groove, and of the various combined bending-torsion loads, on the S-N and Goodman diagrams are determined. Two design applications are presented which illustrate the direct useability and value of the distributional failure governing strength and cycles-to-failure data in designing for specified levels of reliability and in predicting the reliability of given designs.

  11. Plant-based torsional actuator with memory

    Science.gov (United States)

    Plaza, Nayomi; Zelinka, Samuel L.; Stone, Don S.; Jakes, Joseph E.

    2013-07-01

    A bundle of a few loblolly pine (Pinus taeda) cells are moisture-activated torsional actuators that twist multiple revolutions per cm length in direct proportion to moisture content. The bundles generate 10 N m kg-1 specific torque during both twisting and untwisting, which is higher than an electric motor. Additionally, the bundles exhibit a moisture-activated, shape memory twist effect. Over 70% of the twist in a wetted bundle can be locked-in by drying under constraint and then released by rewetting the bundle. Our results indicate that hemicelluloses dominate the shape fixity mechanism and lignin is primarily responsible for remembering the bundle’s original form. The bundles demonstrate proof of a high specific torque actuator with large angles of rotation and shape memory twist capabilities that can be used in microactuators, sensors, and energy harvesters.

  12. Torsional malalignment, how much significant in the trochanteric fractures?

    Science.gov (United States)

    Kim, Tae Young; Lee, Yong Beom; Chang, Jun Dong; Lee, Sang Soo; Yoo, Jae Hyun; Chung, Kook Jin; Hwang, Ji Hyo

    2015-11-01

    The rotational alignment is definitely important in the long bones such as tibias and femurs. We also predict the importance of rotational alignment in the trochanteric fractures. So we measured torsional malalignment in trochanteric fracture and anlaysed their risk factors and their clinical significance. A total of 109 inpatients who had undergone internal fixation following trochanteric fracture and a postoperative pelvic CT scan between 2008 and 2013, with at least one year follow-up, were selected. Factors that affect torsional malalignment, such as age, gender, fracture stability, injured area, operative time, time of surgery after admission, and ASA status, were investigated. Factors that affect the patients' clinical results in malrotation, including ambulation time after surgery, postoperative complication rates, pain assessment of VAS one year postoperatively and Koval score, were also investigated. Of the 109 subjects, torsional malalignment was observed in 28 (25.7%) subjects with a mean torsional malalignment angle of 20.7° (range: -31.2° to 27.1°). Torsional malalignment risk factors were fracture stability (p=0.021) and operative time (p=0.043). In terms of the time to ambulation after surgery, the postoperative complication rates, and the VAS and Koval scores at one year postoperatively, no statistically significant difference was observed between the torsional malalignment patients and the non-deformity patients. In this study, 25.7% of the patients who had undergone internal fixation following trochanteric fracture experienced torsional malalignment. Major factors of the torsional malalignment were an unstable fracture and the consequent delay in the operative time. But the torsional malalignment was deemed to have no effect on clinical results. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. The Strength of Thin-wall Cylinders of D Cross Section in Combined Pure Bending and Torsion

    Science.gov (United States)

    Sherwood, A W

    1943-01-01

    The results of tests of 56 cylinders of D cross section conducted in the Aeronautical Laboratory of the University of Maryland are presented in this report. These cylinders were subjected to pure bending and torsional moments of varying proportions to give the strength under combined loading conditions. The average buckling stress of these cylinders has been related to that of circumscribing circular cylinders for conditions of pure torsion and pure bending and the equation of the interaction curve has been determined for conditions of combined loading.

  14. Axial-torsional fatigue - A study of tubular specimen thickness effects

    Science.gov (United States)

    Bonacuse, Peter J.; Kalluri, Sreeramesh

    1993-01-01

    Experiments were carried out at room temperature on AISI type 316 stainless steel to determine the effect of wall thickness on the cyclic deformation behavior and fatigue life of thin-wall tubular axial-torsional fatigue specimens. The experimental variables examined included the depth of the surface work-hardened layer produced in specimen machining, and the effects of strain range and axial-torsional strain phasing. Tubular fatigue specimens had wall thicknesses of 1.5, 2.0, and 2.5 mm. One as-fabricated specimen from each wall thickness was sectioned for microstructural examination and microhardness measurement. A specimen of each wall thickness was tested in axial-torsional fatigue experiments for each of the three conditions: high strain range in-phase, low strain range in-phase, and low strain range out-of-phase. The machining-induced work-hardened zone, as a percentage of the gage section material, was found to have a minimal effect on both deformation behavior and fatigue life. Out-of-phase fatigue tests displayed shorter fatigue lives and more cyclic hardening than in-phase tests.

  15. Torsional analysis of 1 MW gearbox and shaft system in the Avedoere wind turbine

    International Nuclear Information System (INIS)

    Crone, A.

    1993-05-01

    In order to predict undesired high gear noise emission from the Avedoere wind turbine due to critical torsional resonances in the shaft system, the torsional natural frequencies and corresponding mode shapes have been calculated. The analysis has involved a comprehensive, detailed model of the gearbox shaft system. The natural frequencies and mode shapes have also been calculated for the test bed shaft system enabling a calibration of the calculations when comparing with measurements made on the test bed system. The natural torsional frequencies of the test bed shaft system and the wind turbine shaft system, both including the Flender, Peak 4375 gearbox, have been calculated together with the corresponding mode shapes. The sensitivity analysis showed that the natural frequencies of one of the torsional modes may be close to or coinciding with the toothmesh frequency of the output gear stage, in the wind turbine shaft system. The shape of this mode indicates however, that this mode is not very likely to be strongly excited by forces acting in the tooth contact at the mesh frequency. This conclusion also counts for a second mode which was calculated to have a natural frequency close to the toothmesh frequency of the output stage. The analysis also shows that the frequencies of the 1st, the 3rd and the 4th harmonics of the toothmesh frequency of the 2nd gear stage, deviate by less than 15% from several modes of the wind turbine shaft system, which seem likely to be excited by forces acting in the tooth contact of this stage. Amplification of the structure-borne noise from the gearbox at these frequencies may be expected. The amplification at these frequencies is not expected to have any critical influence on the tonal gear noise radiated from the wind turbine. (EG)

  16. Stability of self-accelerating Universe in modified gravity with dynamical torsion: The case of small background torsion

    Science.gov (United States)

    Nikiforova, Vasilisa

    2018-03-01

    We consider the model of modified gravity with dynamical torsion. This model was found to have promising stability properties about various backgrounds. The model admits a self-accelerating solution. We have shown previously that if the parameters are adjusted in such a way that the torsion is much greater than the effective cosmological constant, the self-accelerating solution is unstable: there are exponentially growing modes. Here, we study the scalar perturbations in the case when the torsion is of the order of the effective cosmological constant. We find that there are no exponential instabilities.

  17. Texture evolution and enhanced grain refinement under high-pressure-double-torsion

    Energy Technology Data Exchange (ETDEWEB)

    Jahedi, Mohammad [Department of Mechanical Engineering, University of New Hampshire, Durham, NH 03824 (United States); Department of Materials Science and Engineering, School of Engineering, Shiraz University, Shiraz (Iran, Islamic Republic of); Paydar, Mohammad Hossein [Department of Materials Science and Engineering, School of Engineering, Shiraz University, Shiraz (Iran, Islamic Republic of); Zheng, Shijian [Materials Physics and Applications Division, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Beyerlein, Irene J. [Theoretical Division, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Knezevic, Marko, E-mail: marko.knezevic@unh.edu [Department of Mechanical Engineering, University of New Hampshire, Durham, NH 03824 (United States)

    2014-08-12

    We present a severe plastic deformation process called high-pressure-double-torsion (HPDT) for grain size refinement in metallic polycrystals. Like standard high-pressure torsion, HPDT monotonically imposes extreme plastic strains (⪢10) but via rotating both ends of the sample rather than one. Commercial purity Cu was subjected to HPT and HPDT for 1, 2, and 4 turns. The grain structure, hardness, and crystallographic texture were examined by transmission electron microscopy (TEM), Vickers microhardness tests, and X-ray diffraction (XRD) in both processes and compared in the mid-radius and at the edge of disks. We report that HPDT leads to finer grain sizes and higher hardness than HPT for the same number of turns. The measured textures exhibit typical shear components, which continuously strengthened with the plastic strain and also weakened with extreme grain refinement. These measurements also indicate that the texture gradients are lower in HPDT than HPT.

  18. Modeling and Calibration for Crack Detection in Circular Shafts Supported on Bearings Using Lateral and Torsional Vibration Measurements

    Directory of Open Access Journals (Sweden)

    A. Tlaisi

    2012-01-01

    Full Text Available In this paper the requisite foundational numerical and experimental investigations that are carried out, to model the “uncracked and cracked” shaft and to identify its bending and torsional vibration responses, are reported. The cylindrical shaft used in this experimental study is continuous over two spans (with a cantilever span carrying a propeller with ball-bearing supports. During modal tests the backward end of shaft (away from the propeller end and connecting it to an electric motor, required for online monitoring is fixed to one of the test frame supports; later on this backward end will be connected to an electric motor to carry out online modal monitoring for crack identification. In the numerical study, beam elements are used for modeling the bending and torsional vibrations of the rotating shaft. The paper describes in detail the numerical “linear spring” models developed for representing the effects of “ball bearings and the (experimental test frame supports” on the vibration frequencies. Shaft response parameters are obtained using modal analysis software, LMS Test Lab, for bending vibrations monitored using accelerometers, and three “sets” of shear strain gages fixed at three different shaft locations measure the torsional vibrations. Effects of different crack depths on bending and torsional frequencies and mode shapes are investigated experimentally and numerically, and the results interpreted to give better comprehension of its vibratory behavior.

  19. Fatigue crack growth in 2017A-T4 alloy subjected to proportional bending with torsion

    Directory of Open Access Journals (Sweden)

    D. Rozumek

    2017-10-01

    Full Text Available The paper presents the results of tests on the fatigue crack growth for a constant moment amplitude under combined bending with torsion in the aluminium alloy AW-2017A-T4. The tests were performed under different values of the load ratio R. Plane specimens with stress concentrators in form of the external one-sided sharp notch were tested. A non-uniform fatigue cracks growth on both lateral surfaces of specimens was observed during experimental tests. Fatigue cracks were developing in the specimens in two stages; quarter-elliptic edge cracks were observed at the beginning, then evolving into through cracks

  20. Viscosity-density sensor with resonant torsional paddle for direct detection in liquid.

    Science.gov (United States)

    Li, H; Wang, J; Li, X; Chen, D

    2011-12-01

    A novel micro-machined biosensor based on the resonant torsional paddle with electromagnetic excitation which can work in liquid directly is presented. The sensor designed consists of two paddles with resonant torsional mode, in which the energy loss of the resonator during the vibration is so lower that it can be suitable for detection in liquid. Finite element method analysis was carried out to guarantee the sensitivity of the sensor. Micro electro-mechanical system (MEMS) bulk silicon processes were adopted to accomplish the fabrication. A positive-feedback circuit with energy compensation is designed to improve the characteristics of the sensor in liquid. Experiments show that the resonant torsional paddle can work directly in liquid and the Q-factor of the sensor in liquid can be improved from 2.65 to 40 with energy compensation. Viscosity tests and density tests for the sensor show that the decrease in frequency and the decrease in Q-factor are related to density and viscosity of the solutions, respectively.

  1. Evaluation of left ventricular torsion in children with hypertrophic cardiomyopathy.

    Science.gov (United States)

    Prinz, Christian; Faber, Lothar; Horstkotte, Dieter; Körperich, Hermann; Moysich, Axel; Haas, Nikolaus; Kececioglu, Deniz; Thorsten Laser, Kai

    2014-04-01

    To evaluate the role of torsion in hypertrophic cardiomyopathy in children. A total of 88 children with idiopathic hypertrophic cardiomyopathy (n = 24) and concentric hypertrophy (n = 20) were investigated with speckle-tracking echocardiography and compared with age- and gender-matched healthy controls (n = 44). In hypertrophic cardiomyopathy, we found increased torsion (2.8 ± 1.6 versus 1.9 ± 1.0°/cm [controls], p Hypertrophic cardiomyopathy patients demonstrated a negative correlation between left ventricular muscle mass and torsion (r = -0.7, p hypertrophic cardiomyopathy is characterised by predominantly enhanced systolic basal clockwise rotation. Diastolic untwisting is delayed in both groups. Torsion may be an interesting marker to guide patients with hypertrophic cardiomyopathy.

  2. Isolated adnexal torsion in a 20-week spontaneous twin pregnancy

    Directory of Open Access Journals (Sweden)

    Ilker Kahramanoglu

    2016-01-01

    Discussion: Adnexal torsion as a cause of acute abdomen may be kept in mind in pregnants, even if there is no predisposing factor. Laparoscopy may be performed safely in 2nd trimester for acute abdomen.

  3. Outcomes of Surgery for Posterior Polar Cataract Using Torsional Ultrasound

    Directory of Open Access Journals (Sweden)

    Selçuk Sızmaz

    2013-10-01

    Full Text Available Purpose: The aim of this study is to report outcomes of surgery for posterior polar cataract using torsional ultrasound. Material and Method: Medical records of 26 eyes of 21 consecutive patients with posterior polar cataract who had cataract surgery using the torsional phacoemulsification were evaluated retrospectively. The surgical procedure used, phacoemulsification parameters, intraoperative complications, and postoperative visual outcome were recorded. Results: Of the 26 eyes, 24 (92.3% had small to medium posterior polar opacity. Two eyes had large opacity. All surgeries were performed using the torsional handpiece. Posterior capsule rupture occurred in 4 (15.3% eyes. The mean visual acuity improved significantly after surgery (p<0.001. The postoperative visual acuity was worse than 20/20 in 5 eyes. The cause of the low acuity was amblyopia. Discussion: Successful surgical results and good visual outcome can be achieved with phacoemulsification using the torsional handpiece. (Turk J Ophthalmol 2013; 43: 345-7

  4. Ovarian sparing surgery in cases of giant torsioned ovarian masses

    Directory of Open Access Journals (Sweden)

    Yesim Bayoglu Tekin

    2015-12-01

    Full Text Available Ovarian torsion is a rare gynecological emergency. ovarian torsion is often seen in reproductive ages and salphingooopherectomy is performed for the treatment. However, surgically excision of one of the ovaries early in life causes severe damage to the future fertility. Many case series that were published recently, has been shown low complication rate of ovarian sparing surgery at ovarian torsion and have been preserved from the organ loss. In this study we presented 3 cases at young ages with giant torsioned adnexal masses managed by ovarian sparing surgery at laparotomy and revised the literature in the light of these cases. [J Contemp Med 2015; 5(4.000: 253-256

  5. Damping of Torsional Beam Vibrations by Control of Warping Displacement

    DEFF Research Database (Denmark)

    Høgsberg, Jan Becker; Hoffmeyer, David; Ejlersen, Christian

    2016-01-01

    Supplemental damping of torsional beam vibrations is considered by viscous bimoments acting on the axial warping displacement at the beam supports. The concept is illustrated by solving the governing eigenvalue problem for various support configurations with the applied bimoments represented...

  6. Torsion of a wandering spleen | Carapinha | South African Journal of ...

    African Journals Online (AJOL)

    Abstract. Torsion of a wandering spleen is a rare and difficult diagnosis in the paediatric population, with death a possible outcome. In this paper we present our experience of a single case and discuss the embryology and management thereof.

  7. Amplitude-temperature analysis of hard rubber by torsional vibration

    Czech Academy of Sciences Publication Activity Database

    Šulc, Petr; Pešek, Luděk; Bula, Vítězslav; Cibulka, Jan; Košina, Jan

    2016-01-01

    Roč. 821, č. 2016 (2016), s. 295-302 ISSN 1660-9336 Institutional support: RVO:61388998 Keywords : hard rubber * torsion vibration * finite deformation * parameter identification Subject RIV: BI - Acoustics

  8. Primary torsion of vermiform appendix mimicking acute appendicitis.

    Science.gov (United States)

    Marsdin, Emma L; Griffiths, Carl

    2011-10-28

    Acute appendicitis is a common condition, 8% of the developed world have an appendicectomy in their lifetime. However, torsion of the appendix is a rare disorder first described in 1918 presenting in a manner undistinguishable from acute appendicitis. The authors describe a case of a 48-year-old man who presented with a short history consistent with acute appendicitis. At open appendicectomy, was found to have an acute clockwise torsion of the vermiform appendix at a point 0.5 cm from its base. Histological examination of the specimen was consistent with torsion of the appendix but no underlying cause for the torsion was identified. The postoperative recovery was uneventful; the patient received intravenous antibiotics for a further 48 h and was discharged home without any complications.

  9. Torsional Failure of Carbon Fiber Composite Plates Versus Stainless Steel Plates for Comminuted Distal Fibula Fractures.

    Science.gov (United States)

    Wilson, William K; Morris, Randal P; Ward, Adam J; Carayannopoulos, Nikoletta L; Panchbhavi, Vinod K

    2016-05-01

    Carbon fiber composite implants are gaining popularity in orthopedics, but with few independent studies of their failure characteristics under supra-physiologic loads. The objective of this cadaveric study was to compare torsional failure properties of bridge plating a comminuted distal fibula fracture with carbon fiber polyetheretherketone (PEEK) composite and stainless steel one-third tubular plates. Comminuted fractures were simulated in 12 matched pairs of fresh-frozen human fibulas with 2-mm osteotomies located 3 cm proximal to the tibiotalar joint. Each fibula pair was randomized for fixation and implanted with carbon fiber and stainless steel 5-hole one-third tubular plates. The constructs were loaded in external rotation at a rate of 1-degree/sec until failure with a materials testing system. Torsional stiffness and mode of failure, as well as displacement, torque, and energy absorption for the first instance of failure and peak failure, were determined. Statistical analysis was performed with paired t tests and chi-square. There were no significant differences among the 12 pairs for torsional stiffness, first failure torque, peak failure displacement, peak failure torque, or peak failure energy. Stainless steel plates exhibited significantly higher displacement (P fibula fracture fixation model, carbon fiber implants exhibited multiple pre-peak failures at significantly lower angles than the first failure for the stainless steel implants, with some delamination of composite layers and brittle catastrophic failure rather than plastic deformation. The torsional failure properties of carbon fiber composite one-third tubular plates determined in this independent study provide novel in vitro data for this alternative implant material. © The Author(s) 2016.

  10. Standardized education and parental awareness are lacking for testicular torsion.

    Science.gov (United States)

    Friedman, Ariella A; Ahmed, Haris; Gitlin, Jordan S; Palmer, Lane S

    2016-06-01

    Testicular torsion leads to orchiectomy in 30-50% of cases, which may cause psychological upset and parental guilt over a potentially avertable outcome. Presentation delay is an important modifiable cause of orchiectomy; yet, families are not routinely educated about torsion or its urgency. The present study assessed parental knowledge regarding acute scrotal pain. An anonymous survey was distributed to parents in Urology and ENT offices, asking about their children's gender and scrotal pain history, urgency of response to a child's acute scrotal pain, and familiarity with testicular torsion. Surveys of 479 urology and 59 ENT parents were analyzed. The results between the two were not statistically different. Among the urology parents, 34% had heard of testicular twisting/torsion, most commonly through friends, relatives or knowing someone with torsion (35%); only 17% were informed by pediatricians (Summary Figure). Parents presenting for a child's scrotal pain were significantly more likely to have heard of torsion (69%) than those presenting for other reasons (30%, OR 5.24, P parents of boys had spoken with their children about torsion. Roughly three quarters of them would seek emergent medical attention - by day (75%) or night (82%) - for acute scrotal pain. However, urgency was no more likely among those who knew about torsion. This was the first study to assess parental knowledge of the emergent nature of acute scrotal pain in a non-urgent setting, and most closely approximating their level of knowledge at the time of pain onset. It also assessed parents' hypothetical responses to the scenario, which was markedly different than documented presentation times, highlighting a potential area for improvement in presentation times. Potential limitations included lack of respondent demographic data, potential sampling bias of a population with greater healthcare knowledge or involvement, and assessment of parents only. Parental knowledge of testicular torsion was

  11. Torsion of the greater omentum: A rare preoperative diagnosis

    International Nuclear Information System (INIS)

    Tandon, Ankit Anil; Lim, Kian Soon

    2010-01-01

    Torsion of the greater omentum is a rare acute abdominal condition that is seldom diagnosed preoperatively. We report the characteristic computed tomography (CT) scan findings and the clinical implications of this unusual diagnosis in a 41-year-old man, who also had longstanding right inguinal hernia. Awareness of omental torsion as a differential diagnosis in the acute abdomen setting is necessary for correct patient management

  12. High rank elliptic curves with torsion ℤ/4ℤ.

    Science.gov (United States)

    Khoshnam, Foad; Moody, Dustin

    2016-01-01

    Working over the field ℚ( t ), Kihara constructed an elliptic curve with torsion group ℤ/4ℤ and five independent rational points, showing the rank is at least five. Following his approach, we give a new infinite family of elliptic curves with torsion group ℤ/4ℤ and rank at least five. This matches the current record for such curves. In addition, we give specific examples of these curves with high ranks 10 and 11.

  13. Model of Structural Fragmentation Induced by High Pressure Torsion

    Czech Academy of Sciences Publication Activity Database

    Kratochvíl, J.; Kružík, Martin; Sedláček, R.

    2010-01-01

    Roč. 25, č. 1 (2010), s. 88-98 ISSN 1606-5131 Institutional research plan: CEZ:AV0Z10750506 Keywords : High-pressure torsion * intergranular glide * homogeneous deformation mode Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 0.649, year: 2010 http://library.utia.cas.cz/separaty/2010/MTR/kruzik-model of structural fragmentation induced by high pressure torsion.pdf

  14. Torsional Moment Measurement on Bucket Wheel Shaft of Giant Machine

    Directory of Open Access Journals (Sweden)

    Jiří FRIES

    2011-06-01

    Full Text Available Bucket wheel loading at the present time (torsional moment on wheel shaft, peripheral cutting force is determined from electromotor incoming power or reaction force measured on gearbox hinge. Both methods together are weighted by steel construction absorption of driving units and by inertial forces of motor rotating parts. In the article is described direct method of the torsional moment measurement, which eliminates mentioned unfavourable impacts except absorption of steel construction of bucket wheel itself.

  15. The variation of torsion with vergence and elevation.

    Science.gov (United States)

    Porrill, J; Ivins, J P; Frisby, J P

    1999-11-01

    Two recently developed kinematic models of human eye movements predict systematic departures from Listing's law which are associated with changes in vergence. This vergence-dependent torsion t is proportional to elevation e and vergence v, that is t = kev/2. The proposed value for k is either 1 (Van Rijn, L. J., & Van den Berg, A. V. (1993). Vision Research, 33, 691-708) or 1/2 (Minken, A. W. H., Gielen, C. C. A. M., & Van Gisbergen, J. A. M. (1995). Vision Research, 35, 93-102). One implication of both models is that an eye with a constant fixation direction should exhibit systematic torsional variation during movements of the other eye. This paper therefore examines the torsion produced by moving a fixation target inwards and outwards along the line-of-sight of the right eye at five different viewing elevations (0, +/- 15 and +/- 30 degrees). In a monocular analysis, each eye generally showed intorsion during convergence at positive elevation angles, whereas extorsion occurred at negative elevations; the opposite was true during divergence. However, the torsion response was visibly different between the five subjects, and depended on the direction of target motion. In a binocular analysis, cycloversion (mean of left and right eye torsion) varied dramatically both between subjects and between convergence and divergence; however, cyclovergence (torsional difference) was much less variable. Least-squares methods were used to estimate the constant k from monocular torsion, yielding values between 0.2 and 1.0; however, corresponding estimates based on cyclovergence were all close to 1/2. These findings support suggestions that a binocular control system couples the three-dimensional movements of the eyes, and that an existing model of monocular torsion should be generalised to the binocular case.

  16. Do physical examination and CT-scan measures of femoral neck anteversion and tibial torsion relate to each other?

    Science.gov (United States)

    Sangeux, Morgan; Mahy, Jessica; Graham, H Kerr

    2014-01-01

    Informed clinical decision making for femoral and/or tibial de-rotation osteotomies requires accurate measurement of patient function through gait analysis and anatomy through physical examination of bony torsions. Validity of gait analysis has been extensively studied; however, controversy remains regarding the accuracy of physical examination measurements of femoral and tibial torsion. Comparison between CT-scans and physical examination measurements of femoral neck anteversion (FNA) and external tibial torsion (ETT) were retrospectively obtained for 98 (FNA) and 64 (ETT) patients who attended a tertiary hospital for instrumented gait analysis between 2007 and 2010. The physical examination methods studied for femoral neck anteversion were the trochanteric prominence angle test (TPAT) and the maximum hip rotation arc midpoint (Arc midpoint) and for external tibial torsion the transmalleolar axis (TMA). Results showed that all physical examination measurements statistically differed to the CT-scans (bias(standard deviation): -2(14) for TPAT, -10(12) for Arc midpoint and -16(9) for TMA). Bland and Altman plots showed that method disagreements increased with increasing bony torsions in all cases but notably for TPAT. Regression analysis showed that only TMA and CT-scan measurement of external tibial torsion demonstrated good (R(2)=57%) correlation. Correlations for both TPAT (R(2)=14%) and Arc midpoint (R(2)=39%) with CT-scan measurements of FNA were limited. We conclude that physical examination should be considered as screening techniques rather than definitive measurement methods for FNA and ETT. Further research is required to develop more accurate measurement methods to accompany instrumented gait analysis. Copyright © 2013. Published by Elsevier B.V.

  17. Bicavitary effusion secondary to liver lobe torsion in a dog

    Directory of Open Access Journals (Sweden)

    Khan Z

    2016-04-01

    Full Text Available Zaheda Khan,1 Kathryn Gates,2 Stephen A Simpson,31Emergency and Critical Care, Animal Specialty and Emergency Center, Los Angeles, CA, 2Emergency and Critical Care, Advanced Critical Care, Emergency and Specialty Services, Culver City, CA 3Emergency and Critical Care, Southern California Veterinary Specialty Hospital, Irvine, CA, USA Abstract: We described the diagnosis and successful treatment of pleural and peritoneal effusion secondary to liver lobe torsion in a dog. A 12-year-old female spayed Borzoi dog was referred for heart failure. Emergency room thoracic and abdominal ultrasound showed a large volume of pleural effusion with mild peritoneal effusion and an abdominal mass. Pleural fluid analysis classified the effusion as exudative. A complete ultrasound revealed mild peritoneal effusion and decreased blood flow to the right liver lobe. Other causes of bicavitary effusion were ruled out based on blood work, ultrasound, echocardiogram, and computed tomography. The patient was taken to surgery and diagnosed with caudate liver lobe torsion and had a liver lobectomy. At the 2-week postoperative recheck, the patient was doing well and there was complete resolution of the pleural effusion. Liver lobe torsion is a rare occurrence in dogs and can be difficult to diagnose. Clinical signs are nonspecific for liver lobe torsion and patients may present in respiratory distress with significant pleural fluid accumulation. When assessing patients with pleural and peritoneal effusion, liver lobe torsion should be considered as a differential diagnosis.Keywords: pleural effusion, peritoneal effusion, hepatic torsion

  18. Effect of Relative Marker Movement on the Calculation of the Foot Torsion Axis Using a Combined Cardan Angle and Helical Axis Approach

    Science.gov (United States)

    Graf, Eveline S.; Wright, Ian C.; Stefanyshyn, Darren J.

    2012-01-01

    The two main movements occurring between the forefoot and rearfoot segment of a human foot are flexion at the metatarsophalangeal joints and torsion in the midfoot. The location of the torsion axis within the foot is currently unknown. The purpose of this study was to develop a method based on Cardan angles and the finite helical axis approach to calculate the torsion axis without the effect of flexion. As the finite helical axis method is susceptible to error due to noise with small helical rotations, a minimal amount of rotation was defined in order to accurately determine the torsion axis location. Using simulation, the location of the axis based on data containing noise was compared to the axis location of data without noise with a one-sample t-test and Fisher's combined probability score. When using only data with helical rotation of seven degrees or more, the location of the torsion axis based on the data with noise was within 0.2 mm of the reference location. Therefore, the proposed method allowed an accurate calculation of the foot torsion axis location. PMID:22666303

  19. Effect of Relative Marker Movement on the Calculation of the Foot Torsion Axis Using a Combined Cardan Angle and Helical Axis Approach

    Directory of Open Access Journals (Sweden)

    Eveline S. Graf

    2012-01-01

    Full Text Available The two main movements occurring between the forefoot and rearfoot segment of a human foot are flexion at the metatarsophalangeal joints and torsion in the midfoot. The location of the torsion axis within the foot is currently unknown. The purpose of this study was to develop a method based on Cardan angles and the finite helical axis approach to calculate the torsion axis without the effect of flexion. As the finite helical axis method is susceptible to error due to noise with small helical rotations, a minimal amount of rotation was defined in order to accurately determine the torsion axis location. Using simulation, the location of the axis based on data containing noise was compared to the axis location of data without noise with a one-sample t-test and Fisher's combined probability score. When using only data with helical rotation of seven degrees or more, the location of the torsion axis based on the data with noise was within 0.2 mm of the reference location. Therefore, the proposed method allowed an accurate calculation of the foot torsion axis location.

  20. Anharmonicity of Coupled Torsions: The Extended Two-Dimensional Torsion Method and Its Use To Assess More Approximate Methods.

    Science.gov (United States)

    Simón-Carballido, Luis; Bao, Junwei Lucas; Alves, Tiago Vinicius; Meana-Pañeda, Rubén; Truhlar, Donald G; Fernández-Ramos, Antonio

    2017-08-08

    In this work we present the extended two-dimensional torsion (E2DT) method and use it to analyze the performance of several methods that incorporate torsional anharmonicity more approximately for calculating rotational-vibrational partition functions. Twenty molecules having two hindered rotors were studied for temperatures between 100 and 2500 K. These molecules present several kinds of situations; they include molecules with nearly separable rotors, molecules in which the reduced moments of inertia change substantially with the internal rotation, and molecules presenting compound rotation. Partition functions obtained by the rigid-rotor harmonic oscillator approximation, a method involving global separability of torsions and the multistructural methods without explicit potential coupling [MS-T(U)] and with explicit potential coupling [MS-T(C)] of torsions, are compared to those obtained with a quantized version - called the extended two-dimensional torsion (E2DT) method - of the extended hindered rotor approximation of Vansteenkiste et al. ( Vansteenkiste et al. J. Chem. Phys. 2006 , 124 , 044314 ). In the E2DT method, quantum effects due to the torsional modes were incorporated by the two-dimensional nonseparable method, which is a method that is based on the solution of the torsional Schrödinger equation and that includes full coupling in both the kinetic and potential energy. By comparing other methods to the E2DT method and to experimental thermochemical data, this study concludes that the harmonic approximation yields very poor results at high temperatures; the global separation of torsions from the rest of the degrees of freedom is not justified even when an accurate method to treat the torsions is employed; it is confirmed that methods based on less complete potential energy coupling of torsions, such as MS-T(U), are not accurate when dealing with rotors with different barrier heights, and more complete inclusion of torsional coupling to the method in MS

  1. Magnetic resonance imaging findings in adnexial torsion

    Energy Technology Data Exchange (ETDEWEB)

    Trindade, Ronald Meira Castro; Quadros, Marianne Siquara de [Hospital Albert Einstein, Sao Paulo, SP (Brazil). Instituto de Ensino e Pesquisa], e-mail: rtrindade@einstein.br; Baroni, Ronaldo Hueb; Rosemberg, Michelle; Racy, Marcelo de Castro Jorge; Tachibana, Adriano [Hospital Albert Einstein, Sao Paulo, SP (Brazil); Funari, Marcelo Buarque de Gusmao [Hospital Albert Einstein, Sao Paulo, SP (Brazil). Imaging Service

    2010-01-15

    Adnexial torsion is an unusual event, but a major cause of abdominal pain in women. It is often associated with ovarian tumor or cyst, but can occur in normal ovaries, especially in children. The twisting of adnexial structures may involve the ovary or tube, but frequently affects both. In most cases, it is unilateral, with slight predilection for the right size. In imaging findings, increased ovarian volume and adnexial masses are observed, with reduced or absent vascularisation. In cases of undiagnosed or untreated complete twist, hemorrhagic necrosis may occur leading to complications; in that, peritonitis is the most frequent. Early diagnosis helps preventing irreversible damage with conservative treatment, thereby saving the ovary. Limitations in performing physical examination, possible inconclusive results in ultrasound and exposure to radiation in computed tomography makes magnetic resonance imaging a valuable tool in emergency assessment of gynecological diseases. The objective of this study was to report two confirmed cases of adnexial twist, emphasizing the contribution of magnetic resonance imaging in the diagnosis of this condition. (author)

  2. Axial torsion and gangrene of Meckel’s diverticulum: Case report

    Directory of Open Access Journals (Sweden)

    Radović Saša V.

    2015-01-01

    Full Text Available Introduction. Meckel’s diverticulum (MD is the most prevalent congenital anomaly of small intestine. It develops due to the incomplete obliteration of omphalomesenterict duct which normally undergoes obliteration during the seventh week of gestation. In the majority of cases MD is asymptomatic but it may cause various complications, such as bleeding, intestinal obstruction and inflammation. Cases of umbilical sinuses, fistulas and neoplasms related with MD have been reported, but extremely rare gangrene due to its axial torsion, especially in children, as is the case of our patients. Case Outline. An 11-year-old boy admitted to hospital due to 24 hours epigastric pain, vomiting and malaise. After a complete physical examination, and appropriate pre-surgical laboratory and radiographic tests, surgical exploration was performed with a midline abdominal incision. On 60th cm proximal to the ileocecal valve we found a long and in a narrow based ganrenous MD with axial torsion and fibrotic cord extending from the tip of MD to the ileal mesentery. Surrounding ileum had normal appearance. A demarcation and subsequent resection of MD and the surrounding ileum was performed with endto- end ileal anastomosis. Postoperative recovery was successful and the patient was discharged after six days. Conclusion. Axial torsion of MD is presented with non-specific abdominal symptoms and difficult preoperative diagnosis. The choice of diagnosis and therapy is surgical exploration and resection of MD.

  3. Surface crack growth in cylindrical hollow specimen subject to tension and torsion

    Directory of Open Access Journals (Sweden)

    V. Shlyannikov

    2015-07-01

    Full Text Available The subject for studies is an aluminium cylindrical hollow specimen with external axial and part circumferential semi-elliptical surface crack undergoing fatigue loads. Both the optical microscope measurements and the crack opening displacement (COD method are used to monitor and calculate both crack depth and crack length during the tests. The variation of crack growth behaviour is studied under cyclic axial tension, pure torsion and combined tension+torsion fatigue loading. For the particular surface flaw geometries considered, the elastic and plastic in-plane and out-of-plane constraint parameters, as well as the governing parameter for stress fields in the form of In-integral and plastic stress intensity factor, are obtained as a function of the aspect ratio, dimensionless crack length and crack depth. The combined effect of tension and torsion loading and initial surface flaw orientation on the crack growth for two type of aluminium alloys is made explicit. The experimental and numerical results of the present study provided the opportunity to explore the suggestion that fatigue crack propagation may be governed more strongly by the plastic stress intensity factor rather than the magnitude of the elastic SIFs alone. One advantage of the plastic SIF is its sensitivity to combined loading due to accounting for the plastic properties of the material.

  4. Multiaxial fatigue criterion based on parameters from torsion and axial S-N curve

    Directory of Open Access Journals (Sweden)

    M. Margetin

    2016-07-01

    Full Text Available Multiaxial high cycle fatigue is a topic that concerns nearly all industrial domains. In recent years, a great deal of recommendations how to address problems with multiaxial fatigue life time estimation have been made and a huge progress in the field has been achieved. Until now, however, no universal criterion for multiaxial fatigue has been proposed. Addressing this situation, this paper offers a design of a new multiaxial criterion for high cycle fatigue. This criterion is based on critical plane search. Damage parameter consists of a combination of normal and shear stresses on a critical plane (which is a plane with maximal shear stress amplitude. Material parameters used in proposed criterion are obtained from torsion and axial S-N curves. Proposed criterion correctly calculates life time for boundary loading condition (pure torsion and pure axial loading. Application of proposed model is demonstrated on biaxial loading and the results are verified with testing program using specimens made from S355 steel. Fatigue material parameters for proposed criterion and multiple sets of data for different combination of axial and torsional loading have been obtained during the experiment.

  5. The effect of torsional muscle dysfunction and surgery on eye position under general anesthesia.

    Science.gov (United States)

    McCall, L C; Isenberg, S J; Apt, L

    1993-01-01

    Under general anesthesia, normal eyes exhibit 2.0 degrees to 2.5 degrees of extorsion. To investigate the effect of torsional muscle dysfunction and surgery on eye position under general anesthesia, we measured the torsional change before and after torsional muscle surgery in 26 eyes of 18 patients with clinical torsional muscle dysfunction. Under general anesthesia, compared with normals, eyes with preoperative intorter overaction or extorter underaction demonstrated a significant intorsional change (P extorsion while intorter strengthening procedures and extorter weakening procedures produced measurable intorsion. Superior oblique tenotomy produced a greater net torsional change than inferior oblique weakening surgery (P < .01). Under general anesthesia, eyes with preoperative torsional muscle dysfunction exhibit torsion in the direction consistent with the dysfunction. After surgery on the torsional muscles, a measurable torsional effect can be demonstrated while the patient is still under general anesthesia.

  6. Evaluation of the Flexibility, Cyclic Fatigue, and Torsional Resistance of Rotary Endodontic Files Made of Different Nickel-Titanium Alloys

    OpenAIRE

    Lopes HP; Lopes WSP; Vieira VTL; Elias CN; Cunha RS

    2016-01-01

    Aim: This study compared the mechanical properties of Profile Vortex, Profile Vortex Blue, and Race rotary files. Materials and Methods: The files were subjected to flexibility, rotating-bending (static and dynamic), and torsional resistance tests. Results: Analysis of the data obtained was performed using ANOVA and Student-Newman-Keuls tests. Significant difference in flexibility was observed between Profile Vortex Blue and the two other files tested (Profile Vortex M Wire and Race) (P0.05)....

  7. Experimental study of the cyclic behaviour of a 316 L stainless steel under complex multiaxial loadings in tension-torsion-internal and external pressures

    International Nuclear Information System (INIS)

    Bocher, L.; Delobelle, P.

    1997-01-01

    This paper is concerned with the experimental determination of the behaviour of a 316 L austenitic stainless steel at room temperature and under non proportional cyclic strainings in tension-torsion-internal and external pressures. The two or three sinusoidal strains were applied both in and out-of-phase and the main investigations deal with the additional hardening due to multiaxiality of the loadings. Typical stabilized hysteresis loops are presented. With respect to the maximum additional hardening the different tests can be classified as follows: in phase tests, out-of-phase internal-external pressures tests, out-of-phase tension-torsion tests and finally tension-torsion-pressure with significant phase angles. (orig.)

  8. Production of nanograined intermetallics using high-pressure torsion

    Energy Technology Data Exchange (ETDEWEB)

    Alhamidi, Ali; Edalati, Kaveh; Horita, Zenji, E-mail: horita@zaiko.kyushu-u.ac.jp [Department of Materials Science and Engineering, Faculty of Engineering, Kyushu University, Fukuoka (Japan)

    2013-11-01

    Formation of intermetallics is generally feasible at high temperatures when the lattice diffusion is fast enough to form the ordered phases. This study shows that nanograined intermetallics are formed at a low temperature as 573 K in Al- 25 mol% Ni, Al- 50 mol.% Ni and Al- 50 mol% Ti powder mixtures through powder consolidation using high-pressure torsion (HPT). For the three compositions, the hardness gradually increases with straining but saturates to the levels as high as 550-920 Hv. In addition to the high hardness, the TiAl material exhibits high yield strength as {approx}3 GPa with good ductility as {approx}23%, when they are examined by micropillar compression tests. X-ray diffraction analysis and high-resolution transmission electron microscopy reveal that the significant increase in hardness and strength is due to the formation of nanograined intermetallics such as Al{sub 3}Ni, Al{sub 3}Ni{sub 2}, TiAl{sub 3}, TiAl{sub 2} and TiAl with average grain sizes of 20-40 nm (author)

  9. ELECTROFORCE 3330 TEST SYSTEM

    Data.gov (United States)

    Federal Laboratory Consortium — The Bose Electroforce 3330 is a test system with an axial electromagnetic linear motor, a torsional motor, and an environmental chamber for high and low temperature...

  10. Torsional fatigue model for limitorque type SMB/SB/SBD actuators for motor-operated valves

    Energy Technology Data Exchange (ETDEWEB)

    Somogyi, D.; Alvarez, P.D.; Kalsi, M.S. [Kalsi Engineering, Inc., Sugar Land, TX (United States)

    1996-12-01

    Kalsi Engineering, Inc. has recently developed a computer program to predict the torsional fatigue life of Limitorque Type SMB/SB/SBD actuators for motor-operated valves under given loading levels, including those that exceed the ratings. The development effort was an outgrowth of the {open_quote}Thrust Rating Increase{close_quote} test program. The fatigue model computes all pertinent stress components and their variations as a function of the loading ramp. The cumulative damage and fatigue life due to stress cycling is computed by use of a modification of Miner`s rule. Model predictions were validated against actual cyclic loading test results.

  11. Torsional fatigue model for limitorque type SMB/SB/SBD actuators for motor-operated valves

    International Nuclear Information System (INIS)

    Somogyi, D.; Alvarez, P.D.; Kalsi, M.S.

    1996-01-01

    Kalsi Engineering, Inc. has recently developed a computer program to predict the torsional fatigue life of Limitorque Type SMB/SB/SBD actuators for motor-operated valves under given loading levels, including those that exceed the ratings. The development effort was an outgrowth of the open-quote Thrust Rating Increase close-quote test program. The fatigue model computes all pertinent stress components and their variations as a function of the loading ramp. The cumulative damage and fatigue life due to stress cycling is computed by use of a modification of Miner's rule. Model predictions were validated against actual cyclic loading test results

  12. [Torsion of wandering spleen in a teenager: about a case].

    Science.gov (United States)

    Dème, Hamidou; Akpo, Léra Géraud; Fall, Seynabou; Badji, Nfally; Ka, Ibrahima; Guèye, Mohamadou Lamine; Touré, Mouhamed Hamine; Niang, El Hadj

    2016-01-01

    Wandering or migrating spleen is a rare anomaly which is usually described in children. Complications, which include pedicle torsion, are common and can be life-threatening. We report the case of a 17 year-old patient with a long past medical history of epigastric pain suffering from wandering spleen with chronic torsion of the pedicle. The clinical picture was marked by spontaneously painful epigastric mass, evolved over the past 48 hours. Abdominal ultrasound objectified heterogeneous hypertrophied ectopic spleen in epigastric position and a subcapsular hematoma. Doppler showed a torsion of splenic pedicle which was untwisted 2 turns and a small blood stream on the splenic artery. Abdominal CT scan with contrast injection showed a lack of parenchymal enhancement of large epigastric ectopic spleen and a subcapsular hematoma. The diagnosis of wandering spleen with chronic torsion of the pedicle complicated by necrosis and subcapsular hematoma was confirmed. The patient underwent splenectomy. The postoperative course was uneventful. We here discuss the contribution of ultrasound and CT scan in the diagnosis of wandering spleen with chronic torsion of the pedicle.

  13. Whirling sign : an imaging finding indicating ovarian torsion

    International Nuclear Information System (INIS)

    Cha, Jang Gyu; Kim, Young Hwa; Kim, Hyun Jung; Chang, Yu Jin; Kim, Young Tong; Cho, Won Soo; Bae, Won Kyung; Kim, Il Young

    1997-01-01

    To present a diagnostic sign on MRI and US in patients with ovarian torsion. We present characteristic imaging findings in eight patients with surgically-proven ovarian torsion. MRI was performed in four patients, CT in six and US in all patients;the procedures including eight transabdominal US (TAS) and three transvaginal US (TVS). In each study, imaging findings were analyzed for the appearance of twisted pedicle and the presence of a 'whirling sign'. The pedicle which indicates ovarian torsion was detected on MRI in all 4 patients, on TAS in 4/7, on TVS in 3/3, and on CT in 4/6. A specific 'whirling sign' was detected on MRI in 2/4 patients, on TAS in 2/4, and on TVS in all three. On CT a 'whirling sign' was not detected. The 'whirling sign' on both MRI and US is a characteristic finding of ovarian torsion;in a patient with adnexal mass and complaining of lower abdominal pain, the presence of this sign is very useful for the diagnosis of ovarian torsion

  14. Prune belly syndrome, splenic torsion, and malrotation: a case report.

    Science.gov (United States)

    Tran, Sifrance; Grossman, Eric; Barsness, Katherine A

    2013-02-01

    An 18 year old male with a history of prune belly syndrome (PBS) presented with acute abdominal pain and palpable left upper quadrant mass. Computed tomography (CT) of the abdomen revealed a medialized spleen with a "whirl sign" in the splenic vessels, consistent with splenic torsion. Coincidentally, the small bowel was also noted to be on the right side of the abdomen, while the colon was located on the left, indicative of malrotation. Emergent diagnostic laparoscopy confirmed splenic torsion and intestinal malrotation. Successful laparoscopic reduction of the splenic torsion was achieved, however, conversion to an open procedure by a vertical midline incision was necessary owing to the patient's unique anatomy. Open splenopexy with a mesh sling and Ladd's procedure were subsequently performed. Malrotation and wandering spleen are known, rare associated anomalies in PBS; however, both have not been reported concurrently in a patient with PBS in the literature. In patients with PBS, acute abdominal pain, and an abdominal mass, high clinical suspicion for gastrointestinal malformations and prompt attention can result in spleen preservation and appropriate malrotation management. We present a case of a teenager who presented with a history of PBS, acute abdominal pain, and a palpable abdominal mass. The patient was found to have splenic torsion and intestinal malrotation. The clinical findings, diagnostic imaging, and surgical treatment options of splenic torsion are reviewed. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Torsion of abdominal appendages presenting with acute abdominal pain

    International Nuclear Information System (INIS)

    Al-Jaberi, Tareq M.; Gharabeih, Kamal I.; Yaghan, Rami J.

    2000-01-01

    Diseases of abnormal appendages are rare causes of abdominal pain in all age groups. Nine patients with torsion and infraction of abdominal appendages were retrospectively reviewed. Four patients had torsion and infarction of the appendices epiploicae, four patients had torsion and infarction of the falciform ligament. The patient with falciform ligament disease represents the first reported case of primary torsion and infarction of the falciform ligament, and the patient with the transverse colon epiplocia represents the first reported case of vibration-induced appendix epiplocia torsion and infarction. The patient with the falciform ligament disease presented with a tender upper abdominal mass and the remaining patients were operated upon with the preoperative diagnosis of acute appendicitis. The presence of normal appendix with free serosanguinous fluid in the peritoneal cavity should raise the possibility of a disease and calls for further evaluation of the intra-abdominal organs. If the diagnosis is suspected preoperatively, CT scan and ultrasound may lead to a correct diagnosis and possibly conservative management. Laparoscopy is playing an increasing diagnostic and therapeutic role in such situations. (author)

  16. On unified field theories, dynamical torsion and geometrical models: II

    International Nuclear Information System (INIS)

    Cirilo-Lombardo, D.J.

    2011-01-01

    We analyze in this letter the same space-time structure as that presented in our previous reference (Part. Nucl, Lett. 2010. V.7, No.5. P.299-307), but relaxing now the condition a priori of the existence of a potential for the torsion. We show through exact cosmological solutions from this model, where the geometry is Euclidean RxO 3 ∼ RxSU(2), the relation between the space-time geometry and the structure of the gauge group. Precisely this relation is directly connected with the relation of the spin and torsion fields. The solution of this model is explicitly compared with our previous ones and we find that: i) the torsion is not identified directly with the Yang-Mills type strength field, ii) there exists a compatibility condition connected with the identification of the gauge group with the geometric structure of the space-time: this fact leads to the identification between derivatives of the scale factor a with the components of the torsion in order to allow the Hosoya-Ogura ansatz (namely, the alignment of the isospin with the frame geometry of the space-time), and iii) of two possible structures of the torsion the 'tratorial' form (the only one studied here) forbid wormhole configurations, leading only to cosmological instanton space-time in eternal expansion

  17. Autoparallel vs. Geodesic Trajectories in a Model of Torsion Gravity

    Directory of Open Access Journals (Sweden)

    Luis Acedo

    2015-11-01

    Full Text Available We consider a parametrized torsion gravity model for Riemann–Cartan geometry around a rotating axisymmetric massive body. In this model, the source of torsion is given by a circulating vector potential following the celestial parallels around the rotating object. Ours is a variant of the Mao, Tegmark, Guth and Cabi (MTGC model in which the total angular momentum is proposed as a source of torsion. We study the motion of bodies around the rotating object in terms of autoparallel trajectories and determine the leading perturbations of the orbital elements by using standard celestial mechanics techniques. We find that this torsion model implies new gravitational physical consequences in the Solar system and, in particular, secular variations of the semi-major axis of the planetary orbits. Perturbations on the longitude of the ascending node and the perihelion of the planets are already under discussion in the astronomical community, and if confirmed as truly non-zero effects at a statistically significant level, we might be at the dawn of an era of torsion phenomenology in the Solar system.

  18. Autoparallel vs. Geodesic Trajectories in a Model of Torsion Gravity

    Science.gov (United States)

    Acedo, Luis

    2015-11-01

    We consider a parametrized torsion gravity model for Riemann-Cartan geometry around a rotating axisymmetric massive body. In this model, the source of torsion is given by a circulating vector potential following the celestial parallels around the rotating object. Ours is a variant of the Mao, Tegmark, Guth and Cabi (MTGC model) in which the total angular momentum is proposed as a source of torsion. We study the motion of bodies around the rotating object in terms of autoparallel trajectories and determine the leading perturbations of the orbital elements by using standard celestial mechanics techniques. We find that this torsion model implies new gravitational physical consequences in the Solar system and, in particular, secular variations of the semi-major axis of the planetary orbits. Perturbations on the longitude of the ascending node and the perihelion of the planets are already under discussion in the astronomical community, and if confirmed as truly non-zero effects at a statistically significant level, we might be at the dawn of an era of torsion phenomenology in the Solar system.

  19. MRI of ovarian torsion: Correlation of imaging features with the presence of perifollicular hemorrhage and ovarian viability

    Energy Technology Data Exchange (ETDEWEB)

    Petkovska, Iva, E-mail: dr.iva.petkovska@gmail.com [Department of Medical Imaging, University of Arizona College of Medicine, Tucson, AZ (United States); Duke, Eugene; Martin, Diego R.; Irani, Zeenia [Department of Medical Imaging, University of Arizona College of Medicine, Tucson, AZ (United States); Geffre, Christopher P. [Department of Pathology, University of Arizona College of Public Health, Tucson, AZ (United States); Cragun, Janiel M. [Department of Obstetrics & Gynecology, University of Arizona College of Medicine, Tucson, AZ (United States); Costello, James R.; Arif-Tiwari, Hina; Czeyda-Pommersheim, Ferenc; Udayasankar, Unni [Department of Medical Imaging, University of Arizona College of Medicine, Tucson, AZ (United States); Kalb, Bobby, E-mail: bkalb@radiology.arizona.edu [Department of Medical Imaging, University of Arizona College of Medicine, Tucson, AZ (United States)

    2016-11-15

    Purpose: The purpose of our study is to test for: (a) correlation between the presence of a perifollicular T2-hypointense rim on MRI with the presence of perifollicular hemorrhage on histology; and (b) correlation between this finding and diminished ovarian viability after intra-operative detorsion. Methods and materials: Our IRB-approved, retrospective study evaluated 780 patients between August 2012 and February 2016 with ovarian torsion as a diagnostic consideration on the emergency department note. Patients were included if they had preoperative MRI and intraoperatively confirmed case of ovarian torsion. MRIs were retrospectively reviewed for presence of perifollicular T2 hypointense rim in the torsed ovary. Two arms of analysis were performed: (a) assessment of perifollicular hemorrhage on histological exam; and (b) assessment of ovarian viability after intra-operative detorsion. Sensitivity, specificity, positive predictive value, and negative predictive value of MRI for predicting ovarian viability in the setting of torsion was performed. κ test assessed level of agreement between readers. Results: 24 patients included in one of the two arms; 20 in viability analysis and 12 in perifollicular hemorrhage analysis (8 in both). The presence of T2-hypointense rim on MRI demonstrated 88.9% sensitivity and 66.7% specificity for the diagnosis of perifollicular hemorrhage on histology, and 91.7% sensitivity and 100% specificity for predicting intraoperative viability. Conclusion: The presence of a perifollicular T2 hypointense rim on MRI in the setting of ovarian torsion correlates with perifollicular hemorrhage on histopathologic exam, and may also be a useful predictor of ovarian viability in patients presenting with ovarian torsion.

  20. Contact-less magneto-elastic torsional sensor based on phase-shift measurements

    International Nuclear Information System (INIS)

    Buchenau, D; Schmidt, G; Eckert, S

    2014-01-01

    a type of sensor are considered by a model based on Maxwell’s equations. Besides the chosen design of a contact-less torsion sensor and an experimental set-up, the obtained test results are illustrated and reported in this paper. (paper)

  1. Abnormalities of Penile Curvature: Chordee and Penile Torsion

    Directory of Open Access Journals (Sweden)

    Sylvia Montag

    2011-01-01

    Full Text Available Congenital chordee and penile torsion are commonly observed in the presence of hypospadias, but can also be seen in boys with the meatus in its orthotopic position. Varying degrees of penile curvature are observed in 4–10% of males in the absence of hypospadias. Penile torsion can be observed at birth or in older boys who were circumcised at birth. Surgical management of congenital curvature without hypospadias can present a challenge to the pediatric urologist. The most widely used surgical techniques include penile degloving and dorsal plication. This paper will review the current theories for the etiology of penile curvature, discuss the spectrum of severity of congenital chordee and penile torsion, and present varying surgical techniques for the correction of penile curvature in the absence of hypospadias.

  2. Increased external tibial torsion in Osgood-Schlatter disease.

    Science.gov (United States)

    Gigante, Antonio; Bevilacqua, Claudia; Bonetti, Massimo G; Greco, Francesco

    2003-08-01

    We studied the relationship between Osgood-Schlatter disease and torsional abnormalities of the lower limb in 21 boys with this condition and 20 age- and sex-matched controls. 3 groups of knees (20 control knees, 21 symptomatic and 21 asymptomatic or less symptomatic knees) were subjected to clinical, radiographic and CT evaluation. We found no statistically significant differences between patients and controls, as regards femoral anteversion, patellar congruence angle, patellar tilt angle and anterior tibial tuberosity-trochlear groove distance, but the condylomalleolar angle and tibial torsion angle were greater in patients. We found no differences between symptomatic and asymptomatic or less symptomatic knees in any of the parameters. All the symptomatic knees were on the side preferentially involved in jumping and sprinting. This increase in external tibial torsion may play a role as a predisposing mechanical factor in the onset of Osgood-Schlatter disease in male athletes.

  3. Mechanical Design of AM Fabricated Prismatic Rods under Torsion

    Directory of Open Access Journals (Sweden)

    Manzhirov Alexander V.

    2017-01-01

    Full Text Available We study the stress-strain state of viscoelastic prismatic rods fabricated or repaired by additive manufacturing technologies under torsion. An adequate description of the processes involved is given by methods of a new scientific field, mechanics of growing solids. Three main stages of the deformation process (before the beginning of growth, in the course of growth, and after the termination of growth are studied. Two versions of statement of two problems are given: (i given the torque, find the stresses, displacements, and torsion; (ii given the torsion, find the stresses, displacements, and torque. Solution methods using techniques of complex analysis are presented. The results can be used in mechanical and instrument engineering.

  4. In vitro transcription of a torsionally constrained template

    DEFF Research Database (Denmark)

    Bentin, Thomas; Nielsen, Peter E

    2002-01-01

    RNA polymerase (RNAP) and the DNA template must rotate relative to each other during transcription elongation. In the cell, however, the components of the transcription apparatus may be subject to rotary constraints. For instance, the DNA is divided into topological domains that are delineated...... of torsionally constrained DNA by free RNAP. We asked whether or not a newly synthesized RNA chain would limit transcription elongation. For this purpose we developed a method to immobilize covalently closed circular DNA to streptavidin-coated beads via a peptide nucleic acid (PNA)-biotin conjugate in principle...... mimicking a SAR/MAR attachment. We used this construct as a torsionally constrained template for transcription of the beta-lactamase gene by Escherichia coli RNAP and found that RNA synthesis displays similar characteristics in terms of rate of elongation whether or not the template is torsionally...

  5. Simple currents versus orbifolds with discrete torsion - a complete classification

    International Nuclear Information System (INIS)

    Kreuzer, M.; Schellekens, A.N.

    1993-01-01

    We give a complete classification of all simple current modular invariants, extending previous results for (Z p ) k to arbitrary centers. We obtain a simple explicit formula for the most general case. Using orbifold techniques to this end, we find a one-to-one correspondence between simple current invariants and subgroups of the center with discrete torsions. As a by-product, we prove the conjectured monodromy independence of the total number of such invariants. The orbifold approach works in a straightforward way for symmetries of odd order, but some modifications are required to deal with symmetries of even order. With these modifications the orbifold construction with discrete torsion is complete within the class of simple current invariants. Surprisingly, there are cases where discrete torsion is a necessity rather than a possibility. (orig.)

  6. Standing torsional waves in a fully saturated, porous, circular cylinder

    CERN Document Server

    Solorza, S; 10.1111/j.1365-246X.2004.02198.x

    2004-01-01

    For dynamic measurement of the elastic moduli of a porous material saturated with viscous fluid using the resonance-bar technique, one also observes attenuation. In this article we have carried out the solution of the boundary-value problem associated with standing torsional oscillations of a finite, poroelastic, circular cylinder cast in the framework of volume-averaged theory of poroelasticity. Analysing this solution by eigenvalue perturbation approach we are able to develop expressions for torsional resonance and temporal attenuation frequencies in which the dependence upon the material properties are transparent. It shows how the attenuation is controlled by the permeability and the fluid properties, and how the resonance frequency drops over its value for the dry solid-frame due to the drag effect of fluid mass. Based upon this work we have a firm basis to determine solid-frame shear modulus, permeability, and tortuosity factor from torsional oscillation experiments.

  7. Fault diagnosis of planetary gearboxes via torsional vibration signal analysis

    Science.gov (United States)

    Feng, Zhipeng; Zuo, Ming J.

    2013-04-01

    Torsional vibration signals are theoretically free from the amplitude modulation effect caused by time variant vibration transfer paths due to the rotation of planet carrier and sun gear, and therefore their spectral structure are simpler than transverse vibration signals. Thus, it is potentially easy and effective to diagnose planetary gearbox faults via torsional vibration signal analysis. We give explicit equations to model torsional vibration signals, considering both distributed gear faults (like manufacturing or assembly errors) and local gear faults (like pitting, crack or breakage of one tooth), and derive the characteristics of both the traditional Fourier spectrum and the proposed demodulated spectra of amplitude envelope and instantaneous frequency. These derivations are not only effective to diagnose single gear fault of planetary gearboxes, but can also be generalized to detect and locate multiple gear faults. We validate experimentally the signal models, as well as the Fourier spectral analysis and demodulation analysis methods.

  8. Seismic performance of square RC bridge columns under combined loading including torsion with low shear.

    Science.gov (United States)

    2009-12-01

    During earthquake excitations, reinforced concrete bridge columns can be subjected to a combination of axial load, shear force, : flexural moments, and torsional moments. The torsional moment can be much more significant in columns of bridges that ar...

  9. Deep learning methods for protein torsion angle prediction.

    Science.gov (United States)

    Li, Haiou; Hou, Jie; Adhikari, Badri; Lyu, Qiang; Cheng, Jianlin

    2017-09-18

    Deep learning is one of the most powerful machine learning methods that has achieved the state-of-the-art performance in many domains. Since deep learning was introduced to the field of bioinformatics in 2012, it has achieved success in a number of areas such as protein residue-residue contact prediction, secondary structure prediction, and fold recognition. In this work, we developed deep learning methods to improve the prediction of torsion (dihedral) angles of proteins. We design four different deep learning architectures to predict protein torsion angles. The architectures including deep neural network (DNN) and deep restricted Boltzmann machine (DRBN), deep recurrent neural network (DRNN) and deep recurrent restricted Boltzmann machine (DReRBM) since the protein torsion angle prediction is a sequence related problem. In addition to existing protein features, two new features (predicted residue contact number and the error distribution of torsion angles extracted from sequence fragments) are used as input to each of the four deep learning architectures to predict phi and psi angles of protein backbone. The mean absolute error (MAE) of phi and psi angles predicted by DRNN, DReRBM, DRBM and DNN is about 20-21° and 29-30° on an independent dataset. The MAE of phi angle is comparable to the existing methods, but the MAE of psi angle is 29°, 2° lower than the existing methods. On the latest CASP12 targets, our methods also achieved the performance better than or comparable to a state-of-the art method. Our experiment demonstrates that deep learning is a valuable method for predicting protein torsion angles. The deep recurrent network architecture performs slightly better than deep feed-forward architecture, and the predicted residue contact number and the error distribution of torsion angles extracted from sequence fragments are useful features for improving prediction accuracy.

  10. Primary decomposition of torsion R[X]-modules

    Directory of Open Access Journals (Sweden)

    William A. Adkins

    1994-01-01

    Full Text Available This paper is concerned with studying hereditary properties of primary decompositions of torsion R[X]-modules M which are torsion free as R-modules. Specifically, if an R[X]-submodule of M is pure as an R-submodule, then the primary decomposition of M determines a primary decomposition of the submodule. This is a generalization of the classical fact from linear algebra that a diagonalizable linear transformation on a vector space restricts to a diagonalizable linear transformation of any invariant subspace. Additionally, primary decompositions are considered under direct sums and tensor product.

  11. A black hole with torsion in 5D Lovelock gravity

    Science.gov (United States)

    Cvetković, B.; Simić, D.

    2018-03-01

    We analyze static spherically symmetric solutions of five dimensional (5D) Lovelock gravity in the first order formulation. In the Riemannian sector, when torsion vanishes, the Boulware–Deser black hole represents a unique static spherically symmetric black hole solution for the generic choice of the Lagrangian parameters. We show that a special choice of the Lagrangian parameters, different from the Lovelock Chern–Simons gravity, leads to the existence of a static black hole solution with torsion, the metric of which is asymptotically anti-de Sitter (AdS). We calculate the conserved charges and thermodynamical quantities of this black hole solution.

  12. Massless fermions and Kaluza--Klein theory with torsion

    International Nuclear Information System (INIS)

    Wu, Y.; Zee, A.

    1984-01-01

    A pure Kaluza--Klein theory contains no massless fermion in four-dimensional theory. We investigate the effect of introducing torsion on the internal manifold and find that there are massless fermions. The hope is that given an isometry group the representation to which these fermions belong is fixed, in contrast to the situation in Yang--Mills theory. We show that this is indeed the case, but the representations do not appear to be the ones favored by current theoretical prejudice. The cases with parallelizable torsions on a group manifold as the internal manifold are analyzed in detail

  13. Spontaneous compactification and Ricci-flat manifolds with torsion

    International Nuclear Information System (INIS)

    McInnes, B.

    1985-06-01

    The Freund-Rubin mechanism is based on the equation Rsub(ik)=lambdagsub(ik) (where lambda>0), which, via Myers' Theorem, implies ''spontaneous'' compactification. The difficulties connected with the cosmological constant in this approach can be resolved if torsion is introduced and lambda set equal to zero, but then compactification ''by hand'' is necessary, since the equation Rsub(ik)=0 can be satisfied both on compact and on non-compact manifolds. In this paper we discuss the global geometry of Ricci-flat manifolds with torsion, and suggest ways of restoring the ''spontaneity'' of the compactification. (author)

  14. [Torsion of the vermiform appendix associated with intussusception].

    Science.gov (United States)

    Baeza-Herrera, Carlos; García-Cabello, Luis Manuel; León-Cruz, Alberto; Martínez-Rivera, María de Lourdes

    2006-01-01

    Vermiform appendix torsion is a rare condition, with only 25 cases recorded in the international literature. Our patient is the first case associated with intussusception. A 2-month-old female infant suddenly developed severe abdominal pain due to ileoceal intussusception. During surgical exploration, a tight intussusception was reduced. Three days later, a new laparotomy was required and we found torsion and perforation of the vermiform appendix. The patient underwent appendectomy, but there was dehiscence of the appendiceal stump and cecal perforation requiring a new surgical exploration. The patient had an uneventful recovery.

  15. Temporal discrimination threshold: VBM evidence for an endophenotype in adult onset primary torsion dystonia.

    OpenAIRE

    REILLY, RICHARD; WHELAN, ROBERT

    2009-01-01

    PUBLISHED Familial adult-onset primary torsion dystonia is an autosomal dominant disorder with markedly reduced penetrance. Most adult-onset primary torsion dystonia patients are sporadic cases. Disordered sensory processing is found in adult-onset primary torsion dystonia patients; if also present in their unaffected relatives this abnormality may indicate non-manifesting gene carriage. Temporal discrimination thresholds (TDTs) are abnormal in adult-onset primary torsion dystonia, but the...

  16. Buckling resistance, bending stiffness, and torsional resistance of various instruments for canal exploration and glide path preparation.

    Science.gov (United States)

    Kwak, Sang-Won; Ha, Jung-Hong; Lee, WooCheol; Kim, Sung-Kyo; Kim, Hyeon-Cheol

    2014-11-01

    This study compared the mechanical properties of various instruments for canal exploration and glide-path preparations. The buckling resistance, bending stiffness, ultimate torsional strength, and fracture angle under torsional load were compared for C+ file (CP, Dentsply Maillefer), M access K-file (MA, Dentsply Maillefer), Mani K-file (MN, Mani), and NiTiFlex K-file (NT, Dentsply Maillefer). The files of ISO size #15 and a shaft length of 25 mm were selected. For measuring buckling resistance (n = 10), the files were loaded in the axial direction of the shaft, and the maximum load was measured during the files' deflection. The files (n = 10) were fixed at 3-mm from the tip and then bent 45° with respect to their long axis, while the bending force was recorded by a load cell. For measuring the torsional properties, the files (n = 10) were also fixed at 3-mm, and clockwise rotations (2-rpm) were applied to the files in a straight state. The torsional load and the distortion angle were recorded until the files succumbed to the torque. The CP was shown to require the highest load to buckle and bend the files, and the NT showed the least. While MA and MN showed similar buckling resistances, MN showed higher bending stiffness than MA. The NT had the lowest bending stiffness and ultimate torsional strength (p < 0.05). The tested instruments showed different mechanical properties depending on the evaluated parameters. CP and NT files were revealed to be the stiffest and the most flexible instruments, respectively.

  17. Ultrasonographic diagnosis of torsion of testicular appendages; Diagnostico por ecografia de la torsion de los apendices testiculares

    Energy Technology Data Exchange (ETDEWEB)

    Esparza, J.; Gonzalez, A.; Cordero, J. L. [Hospital Virgen del Camino. Pamplona (Spain)

    2000-07-01

    To determine the efficacy of ultrasound in boys presenting torsion of a testicular appendage. A series of 30 boys with acute scrotal pain due to torsion of a testicular appendage was studied. Nine patients underwent surgery. The clinical findings and course in the remaining 21 suggested the presence of this abnormality. All of them underwent conventional and color Doppler ultrasound using a 7.5 MHz transducer. In 15 boys, ultrasound images depicted the affected appendage as a mass between the epididymal head and the testicle. In 13 cases, only signs of a inflammatory reaction, with enlargement of the epididymal head and tunicas presenting hyperflow and hydrocele, mimicking acute epididymities. In two cases, the images were normal. There is no definitive, distinguishing ultrasound image corresponding to testicular appendage torsion. Therefore, this diagnostic technique should be accompanied by clinical assessment. (Author) 14 refs.

  18. APPLICATION OF THE METHOD OF DIMENSIONALITY REDUCTION TO CONTACTS UNDER NORMAL AND TORSIONAL LOADING

    Directory of Open Access Journals (Sweden)

    Emanuel Willert

    2015-08-01

    In view of all this, the torsional contact problems have been disregarded until now, although it is known that torsion is a major reason of wear and possible failure of system components. Therefore, in the present paper, we extend the MDR to contacts of axisymmetric profiles under superimposed normal and torsional loading.

  19. Effect of combined tensile, bending and torsion deformation on medium carbon steel wire

    Directory of Open Access Journals (Sweden)

    Polyakova Marina

    2017-01-01

    Full Text Available Such schemes of plastic deformation as bending, torsion, tension, compression etc. are considered to be the basic schemes for metal processing methods. Each of these types of deformation has specific influence on microstructure and mechanical properties of the processed metal. For the optimal result of plastic deformation impact on metal structure and properties the mechanism of plastic processing should follow the definite requirements. The effect of different kinds of deformation on medium carbon steel wire was studied using several methods: scanning electron microscopy, atomic force microscopy, dynamic hardness testing. The obtained results can be used in the design of combined methods of deformation processing of carbon steel.

  20. [The effect of weakening inferior oblique muscles on the status of ocular torsion].

    Science.gov (United States)

    Mai, Guang-Huan; Yu, Xin-Ping; Yu, Huan-Yun; Chen, Jing-Chang; Deng, Da-Ming; Lin, Xiao-Ming; Kang, Ying; Wu, He-Ping

    2004-04-01

    To understand the clinical significance of subjective and objective examination of cyclodeviations and investigate the effect of weakening inferior oblique muscles on the status of ocular torsion. Twenty patients (40 eyes) with overacting inferior oblique muscles underwent bilateral myotomy or partial myectomy of inferior oblique muscles. Subjective cyclodeviations were measured before surgery as well as one week, two months after surgery by double maddox rod test (DMRT). Objective cyclodeviations were assessed by fundus photography before and 7 days after surgery in 15 cases. The photograph was transferred to a computer, and the fovea-disc angle was measured by means of drawing picture software. Nine patients with primary overaction of inferior oblique muscles were negative with DMRT before surgery, and only one case revealed incyclotropia 5.0 degrees tested two months after surgery. Four out of 11 patients with secondary overaction of inferior oblique muscles showed excyclotropia 2.5 degrees - 5.0 degrees with DMRT before surgery, and all patients indicated no subjective cyclotropia with DMRT two months after surgery. Fundus photography determination of the right eye revealed extorsion 16.83 degrees +/- 6.39 degrees, the left eye 14.92 degrees +/- 4.51 degrees before surgery. The reduction of the cyclodeviations by weakening inferior oblique muscle for the right and left eye was 13.07 degrees +/- 3.38 degrees and 10.54 degrees +/- 3.75 degrees respectively. The comparison of objective ocular torsion for both eyes showed high significant differences (P < 0.01) pre- and post-operatively. The results of subjective and objective examination of cyclodeviations in patients with primary or secondary overacting inferior oblique muscle early after birth were not consistent. Weakening inferior oblique muscle could correct excyclodeviation. There exist complicated compensatory mechanisms for subjective change of ocular torsion after surgery. The changes of subjective and

  1. Determination of the Glass-Transition Temperature of GRPS and CFRPS Using a Torsion Pendulum in Regimes of Freely Damped Vibrations and Quasi-Stastic Torsion of Specimens

    Science.gov (United States)

    Startsev, V. O.; Lebedev, M. P.; Molokov, M. V.

    2018-03-01

    A method to measure the glass-transition temperature of polymers and polymeric matrices of composite materials with the help of an inverse torsion pendulum over a wide range of temperatures is considered combining the method of free torsional vibrations and a quasi-static torsion of specimens. The glass-transition temperature Tg of a KMKS-1-80. T10 fiberglass, on increasing the frequency of freely damped torsional vibrations from 0.7 to 9.6 Hz, was found to increase from 132 to 140°C. The value of Tg of these specimens, determined by measuring the work of their torsion through a small fixed angle was 128.6°C ± 0.8°C. It is shown that the use of a torsion pendulum allows one to determine the glass-transition temperature of polymeric or polymer matrices of PCMs in dynamic and quasi-static deformation regimes of specimens.

  2. Torsion Pendulum Experiment at the International Physics Olympiad

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 5; Issue 6. Torsion Pendulum Experiment at the International Physics Olympiad. Sandeep Bala. Classroom Volume 5 Issue 6 June 2000 pp 76-85. Fulltext. Click here to view fulltext PDF. Permanent link:

  3. Axial Torsion of Gangrenous Meckel's Diverticulum Causing Small ...

    African Journals Online (AJOL)

    dividing the band. Resection and anastomosis of the small bowel including the MD was performed. We hereby report a rare and unusual complication of a MD. Although treatment outcome is generally good, pre-operative diagnosis is often difficult. Key words: Axial torsion, Meckel's diverticulum, small bowel obstruction.

  4. Effect of irregularity on torsional surface waves in an initially ...

    Indian Academy of Sciences (India)

    The Earth is considered as an initially stressed body with a layered ... Keywords. Torsional wave; anisotropy; initial stress; irregularity; non-homogeneity. J. Earth Syst. Sci., DOI 10.1007/s12040-016-0689-7, 125, No. 4, June 2016, pp. 885–895 ...... wave dispersion in a finitely prestrained hollow sandwich circular cylinder; J.

  5. Torsional vibrations of infinite composite poroelastic cylinders | Shah ...

    African Journals Online (AJOL)

    The displacements of second and third torsional modes are determined and presented graphically for the ratio of radius of composite poroelastic solid cylinder to the radius of the inner solid cylinder. Results of previous works are shown as special case of the present analysis. By ignoring liquid effects, the results of purely ...

  6. Torsional vibration of thin-walled elastic beams with doubly ...

    African Journals Online (AJOL)

    In this paper, the problem of analyzing the torsional vibration of thin-walled elastic beams, with open cross-sections that are doubly symmetric and traversed by moving concentrated masses at constant speeds is addressed. The mathematical model adopted accounts for both the gravitational and inertial effects of the ...

  7. The ground state torsion rotation spectrum of CH2DOH

    Science.gov (United States)

    Pearson, John C.; Yu, Shanshan; Drouin, Brian J.

    2012-10-01

    The ground state torsion rotation spectrum of CH2DOH has been completely characterized through J = 30 and Ka = 10, 9, 9 in the three torsional sub-states of the ground state; e0, e1, and o1, respectively. Additional a-type assignments are presented to Ka = 11 in each of the torsional sub-states. The data has been analyzed with an empirical power series model as well as an empirical internal axis model. Over 8000 transitions have been assigned and fit with near experimental accuracy over the range of 4-1628 GHz. The characterization of the spectrum allows for a complete set of ground state term values enabling a better understanding of the infrared spectrum. Comparison of the torsional contributions of the Hamiltonian with normal methanol provides great insight into the nature of the asymmetric-top asymmetric-frame internal rotation problem. The comparison with normal methanol also provides a relatively straightforward transformation from the well understood C3V internal rotation problem to the completely asymmetric internal rotation problem. The data and analysis provide some practical wisdom on the impacts of breaking the symmetry and the choice of models for addressing the nearly three fold completely asymmetric internal rotation problem.

  8. Influence of rigid boundary on the propagation of torsional surface ...

    Indian Academy of Sciences (India)

    Influence of rigid boundary on the propagation of torsional surface wave in an inhomogeneous layer. Shishir Gupta. ∗. , Rehena Sultana and Santimoy Kundu. Department of Applied Mathematics, Indian School of Mines, Dhanbad 826 004, India. ∗. Corresponding author. e-mail: shishir ism@yahoo.com. The present work ...

  9. Influence of rigid boundary on the propagation of torsional surface ...

    Indian Academy of Sciences (India)

    ered media are very important to seismologists in understanding the cause and ... layered media. Bhattacharya (1975) investigated the torsional wave propagation in a two layered circular cylinder with imperfect bond. Vardoulakis. (1984) has shown that ...... Naturalist Society in Zurich 66 181–195. Ozturk A and Akbarov S D ...

  10. Penile Torsion: an Overlooked Anomaly with Distal Hypospadias ...

    African Journals Online (AJOL)

    The angle of penile rotation was measured on an end-on digital photograph of the penis, using MillenMed DICOM viewer program for image analysis. Two techniques were used to correct penile torsion. In group A (9 patients), we used the technique of degloving and repositioning the penile skin. In group B (10 patients), we ...

  11. Portal venous thrombosis developing after torsion of a wandering ...

    African Journals Online (AJOL)

    The etiological factors are the congenital absence of the ligaments that hold the spleen in its normal anatomic position, or the relaxation of these ligaments resulting from conditions like trauma and abdominal surgery. We aimed to present a rare case with torsion of wandering spleen that consequently developed thrombosis ...

  12. Penile torsion correction by diagonal corporal plication sutures

    Directory of Open Access Journals (Sweden)

    Brent W. Snow

    2009-02-01

    Full Text Available Penile torsion is commonly encountered. It can be caused by skin and dartos adherence or Buck’s fascia attachments. The authors suggest a new surgical approach to solve both problems. If Buck’s fascia involvement is demonstrated by artificial erection then a new diagonal corporal plication suture is described to effectively solve this problem.

  13. In vitro transcription of a torsionally constrained template

    DEFF Research Database (Denmark)

    Bentin, Thomas; Nielsen, Peter E

    2002-01-01

    of torsionally constrained DNA by free RNAP. We asked whether or not a newly synthesized RNA chain would limit transcription elongation. For this purpose we developed a method to immobilize covalently closed circular DNA to streptavidin-coated beads via a peptide nucleic acid (PNA)-biotin conjugate in principle...

  14. Ocular torsion before and after 1 hour centrifugation

    NARCIS (Netherlands)

    Groen, E.; Graaf, B. de; Bles, W.; Bos, J.E.

    1996-01-01

    To assess a possible otolith contribution to effects observed following prolonged expo-sure to hyper gravity, we used video-oculography to measure ocular torsion during static and dynamic conditions of lateral body tilt (roll) before and after one hour of centrifugation with a Gx-load of 3G. Static

  15. Ocular torsion before and after 1 hour centrifugation

    NARCIS (Netherlands)

    Groen, Eric; De Graaf, Bernd; Bles, Willem; Bos, Jelte E.

    1996-01-01

    To assess a possible otolith contribution to effects observed following prolonged exposure to hypergravity, we used video oculography to measure ocular torsion during static and dynamic conditions of lateral body tilt (roll) before and after t h of centrifugation with a G(x)-load of 3 G. Static tilt

  16. Investigation of torsional vibrations in thick walled hollow poroelastic ...

    Indian Academy of Sciences (India)

    Abstract. This paper deals with the study of torsional vibrations of thick walled hollow poroelastic cylinder using Biot's extension theory. Considering the boundaries to be stress free, the frequency equation is obtained in the presence of dissipation which is transcendental and complex valued in nature. In the special case of ...

  17. Static balancing of an inverted pendulum with prestressed torsion bars

    NARCIS (Netherlands)

    Radaelli, G.; Buskermolen, R; Barents, R; Herder, J.L.

    2017-01-01

    This paper presents a method for the design of a statically balanced inverted pendulum. The non-linear moment-rotation characteristic of the pendulum's weight is approximated by a piecewise linear characteristic. Each transition is realized by engaging or disengaging one or more torsion bars, by

  18. Testicular torsion: Needless testicular loss can be prevented

    African Journals Online (AJOL)

    2011-12-06

    Dec 6, 2011 ... Background: The risk of losing the testis is an ever present threat in patients with testicular torsion, who delay before presenting to the surgeon. A retrospective study was carried out to audit patients with acute scrotal pain who came to the Trans Ekulu Hospital Enugu, the promptness of offering them surgical ...

  19. Development of Torsional and Linear Piezoelectrically Driven Motors

    Science.gov (United States)

    Duong, Khanh; Newton, David; Garcia, Ephrahim

    1996-01-01

    The development of rotary and linear inchworm-motors using piezoelectric actuators is presented. The motors' design has the advantage of a macro and micro stepper motor with high load and speed. The torsional design is capable of fast angular positioning with micro level accuracy. Additionally, the rotary motor, as designed, can be used as a clutch/brake mechanism. Constructed prototype motors of both types along with their characteristics are presented. The torsional motor consists of a torsional section that provides angular displacement and torque, and two alternating clamping sections which provide the holding force. The motor relies on the principal piezoelectric coupling coefficient (d33) with no torsional elements, increasing its torque capability. The linear motor consists of a longitudinal vibrator that provides displacement and load, and two alternating clamping sections which provide the holding force. This design eliminates bending moment, tension and shear applied to the actuator elements, increase its load capability and life. Innovative flexure designs have been introduced for both motor types. Critical issues that affect the design and performance of the motors are explored and discussed. Experiments are performed demonstrating the motor prototypes based on the aforementioned design considerations.

  20. Torsion of bars with regular polygonal sections | Zongo | Global ...

    African Journals Online (AJOL)

    In this article, the study of the torsion of cylindrical bars using large singular finite elements method leads to the resolution of the system of linear equations using MATLAB software. Particularly, the numerical solution of the problem of beams with regular section shows clearly the precision of the method depending upon the ...

  1. Tumour, Torsion or Trauma? | Nduhiu | Annals of African Surgery

    African Journals Online (AJOL)

    We present a case of a 22 year old who was managed by various levels of clinicians for a 12 day period prior to testicular exploration which finally revealed testicular torsion. Remarkably, the testis was viable and the finding of a hematoma of the epididymis suggested a history of trauma which was not forthcoming from the ...

  2. Testicular torsion on the Jos Plateau | Ugwu | West African Journal ...

    African Journals Online (AJOL)

    In order to determine the pattern and the factors that influenced outcome, we retrospectively studied fifty-seven patients with torsion of the testis admitted to the Jos University Teaching hospital between August 1993 and July 2001. The age ranged from 2 to 55 years with a mean of 22.7 years. Majority (79%) of the patients ...

  3. Origin of methyl torsional potential barrier–An overview

    Indian Academy of Sciences (India)

    This paper presents the evolution of views on methyl internal rotation potential barrier. Various mechanisms proposed for the origin of torsional barrier in ethane have been reviewed. Inadequacy of one dimensional description of internal rotation has been highlighted in small methyl conjugated molecules in the light of its ...

  4. Testicular torsion: Needless testicular loss can be prevented | Njeze ...

    African Journals Online (AJOL)

    Background: The risk of losing the testis is an ever present threat in patients with testicular torsion, who delay before presenting to the surgeon. A retrospective study was carried out to audit patients with acute scrotal pain who came to the Trans Ekulu Hospital Enugu, the promptness of offering them surgical treatment and ...

  5. Timoshenko–Wagner–Kappus Torsion Bending Theory and Wind ...

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 7; Issue 10. Timoshenko–Wagner–Kappus Torsion Bending Theory and Wind Tunnel Balance Design. S P Govinda Raju K R Y Simha. General Article Volume 7 Issue 10 October 2002 pp 54-58 ...

  6. f(R) gravity, torsion and non-metricity

    International Nuclear Information System (INIS)

    Sotiriou, Thomas P

    2009-01-01

    For both f(R) theories of gravity with an independent symmetric connection (no torsion), usually referred to as Palatini f(R) gravity theories, and for f(R) theories of gravity with torsion but no non-metricity, called U4 theories, it has been shown that the independent connection can actually be eliminated algebraically, as long as this connection does not couple to matter. Remarkably, the outcome in both cases is the same theory, which is dynamically equivalent with an ω 0 = -3/2 Brans-Dicke theory. It is shown here that even for the most general case of an independent connection with both non-metricity and torsion, one arrives at exactly the same theory as in the more restricted cases. This generalizes the previous results and explains why assuming that either the torsion or the non-metricity vanishing ultimately leads to the same theory. It also demonstrates that f(R) actions cannot support an independent connection which carries dynamical degrees of freedom, irrespective of how general this connection is, at least as long as there is no connection-matter coupling. (fast track communication)

  7. Increased external tibial torsion and osteochondritis dissecans of the knee

    NARCIS (Netherlands)

    Bramer, J. A. M.; Maas, M.; Dallinga, R. J.; te Slaa, R. L.; Vergroesen, D. A.

    2004-01-01

    In the past, osteochondritis dissecans of the knee was associated with increased tibial exotorsion, established with a clinical measuring method. Now the gold standard for determining tibial torsion is computed tomography. The aim of the current study was to establish whether the abovementioned

  8. Direct excitation of resonant torsional Alfven waves by footpoint motions

    NARCIS (Netherlands)

    Ruderman, M. S.; Berghmans, D.; Goossens, M.; Poedts, S.

    1997-01-01

    The present paper studies the heating of coronal loops by linear resonant Alfven waves that are excited by the motions of the photospheric footpoints of the magnetic field lines. The analysis is restricted to torsionally polarised footpoint motions in an axially symmetric system so that only

  9. Torsion of an Epiploic Appendix Pretending as Acute Appendicitis

    Directory of Open Access Journals (Sweden)

    Kamran Ahmad Malik

    2010-07-01

    Full Text Available Torsion of an epiploic appendix is a rare surgical entity. Its unusual symptomatology, wide variation in physical findings and the absence of helpful laboratory and radiological studies makes it very difficult to diagnose pre-operatively. This is a report of this rare entity found in a patient upon diagnostic laparoscopy performed for suspected acute appendicitis

  10. Absence of torsion for NK_1(R) over associative rings

    OpenAIRE

    Basu, Rabeya

    2010-01-01

    When R is a commutative ring with identity, and if k is a natural number with kR = R, then C. Weibel proved that SK_1(R[X]) has no k-torsion. We reprove his result for any associative ring R with identity in which kR = R.

  11. Spectral Action for Torsion with and without Boundaries

    DEFF Research Database (Denmark)

    Iochum, B.; Levy, Cyril Olivier; Vassilevich, D.

    2012-01-01

    We derive a commutative spectral triple and study the spectral action for a rather general geometric setting which includes the (skew-symmetric) torsion and the chiral bag conditions on the boundary. The spectral action splits into bulk and boundary parts. In the bulk, we clarify certain issues...

  12. Torsion of the Spermatic Cord: An Exemplary Early Presentation

    African Journals Online (AJOL)

    2017-10-26

    Oct 26, 2017 ... Case Report. How to cite this article: Oluyemi OY. Torsion of the spermatic cord: an exemplary early presentation. Niger J Clin Pract 2017;XX;000-000. This is an open ... and the new creations are licensed under the identical terms. For reprints contact: ..... Financial Source of Support. None. Conflicts of ...

  13. Quantum torsion with non-zero standard deviation: Non-perturbative approach for cosmology

    Energy Technology Data Exchange (ETDEWEB)

    Dzhunushaliev, Vladimir, E-mail: v.dzhunushaliev@gmail.com [Dept. Theor. and Nucl. Phys., KazNU, Almaty, 010008 (Kazakhstan); Institute for Basic Research, Eurasian National University, Astana, 010008 (Kazakhstan); Institute of Physicotechnical Problems and Material Science of the NAS of the Kyrgyz Republic, 265 a, Chui Street, Bishkek, 720071 (Kyrgyzstan); Institut für Physik, Universität Oldenburg, Postfach 2503, D-26111 Oldenburg (Germany); Folomeev, Vladimir, E-mail: vfolomeev@mail.ru [Institute of Physicotechnical Problems and Material Science of the NAS of the Kyrgyz Republic, 265 a, Chui Street, Bishkek, 720071 (Kyrgyzstan); Institut für Physik, Universität Oldenburg, Postfach 2503, D-26111 Oldenburg (Germany); Kleihaus, Burkhard, E-mail: b.kleihaus@uni-oldenburg.de [Institut für Physik, Universität Oldenburg, Postfach 2503, D-26111 Oldenburg (Germany); Kunz, Jutta, E-mail: jutta.kunz@uni-oldenburg.de [Institut für Physik, Universität Oldenburg, Postfach 2503, D-26111 Oldenburg (Germany)

    2013-02-12

    Cosmology with non-perturbative quantum corrections resulting from torsion is considered. It is shown that the evolution of closed, open and flat Universes is changed because of the presence of a non-zero dispersion of quantum torsion. The evolution of a Universe with quantum torsion and with one type of average curvature can be similar to the evolution of a Universe without quantum torsion and with another type of average curvature. For the description of the non-perturbative quantum torsion, a vector field approximation is applied.

  14. Cantilever Wings for Modern Aircraft: Some Aspects of Cantilever Wing Construction with Special Reference to Weight and Torsional Stiffness

    Science.gov (United States)

    Stieger, H J

    1929-01-01

    In the foregoing remarks I have made an attempt to touch on some of the structural problems met with in cantilever wings, and dealt rather fully with a certain type of single-spar construction. The experimental test wing was a first attempt to demonstrate the principles of this departure from orthodox methods. The result was a wing both torsionally stiff and of light weight - lighter than a corresponding biplane construction.

  15. Technical study of torsional transit-time magnetic pumping (TTMP) heating. Application for PETULA and large machines

    International Nuclear Information System (INIS)

    Brossaud, J.; Lanier, R.; Perin, J.P.; Rey, G.

    1980-11-01

    This report describes a computer program which determines the RF current distributions and the corresponding voltage and dissipated powers in the conductors for the application of torsional TTMP heating. The results fit well with a Petula-scale experiments. Two prototype coils have been studied and tested for Petula. The application for JET points out the main technical problems which need further developments to ensure the technical feasibility of this method [fr

  16. Design, Development and Scaling Analysis of a Variable Stiffness Magnetic Torsion Spring

    Directory of Open Access Journals (Sweden)

    Angelo Sudano

    2013-10-01

    Full Text Available In this paper we report on the design, modeling, experimental testing and scaling analysis of a novel MAgnetic Variable stiffnEess spRIng-Clutch (MAVERIC device, which may be used as the elastic element of Variable Stiffness Actuators (VSAs. The device, comprising two co-axial diametrically magnetized hollow cylinders, has two degrees of freedom: a rotation of the two cylinders around the common axis and a relative translation along the same axis. For small rotations, the torque arising from the magnetic interaction of the two cylinders is almost linearly proportional to their relative rotation, as in mechanical torsion springs. In addition, the stiffness of the equivalent spring can be varied continuously from a maximum value down to exactly zero by changing the axial overlap of the two cylinders. In this way the proposed device can be used both as a clutch (i.e., perfectly compliant element and as a variable stiffness torsion spring. A prototype, designed after magnetostatic FEM simulations, has been built and experimentally characterized. The developed MAVERIC has an experimentally determined maximum transmissible torque of 109.81mNm, while the calculated maximum stiffness is 110.2mNmrad−1. The amplitude of the torque-angle characteristic can be tuned linearly with a sensitivity of 12.63mNmmm−1 rad−1. Further simulations have been computed parameterizing the geometry and the number of pole pairs of the magnets. The maximum torque density reached for one pole pair is 47.21 · 103 Nm m−3, whereas for a fixed geometry similar to that of the developed prototype, the maximum torque is reached for seven pole pairs. Overall, compared to mechanical springs, MAVERIC has no fatigue or overloading issues. Compared to other magnetic couplers, torsion stiffness can be varied continuously from a maximum value down to exactly zero, when the device acts as a disengaged clutch, disconnecting the load from the actuator.

  17. Study of the dynamic Bauschinger effect in Ti6Al4V by torsion experiments

    Directory of Open Access Journals (Sweden)

    Degrieck J.

    2012-08-01

    Full Text Available The materials kinematic hardening behaviour and Bauschinger effect is indispensible to describe complex deformation processes involving strain path changes. Moreover, the Bauschinger effect provides valuable information about underlying microstructural plasticity mechanisms. Until now, the Bauschinger effect at high strain rates remains a largely unexplored topic. However, different studies demonstrated the strain rate dependent character of the Bauschinger effect. The aim of this work is to study the dynamic Bauschinger effect by means of a novel experimental technique. A modified torsional split Hopkinson bar setup is used to conduct Bauschinger experiments on Ti6Al4V. Forward and reverse loading of the specimen take place successively in only one experiment. This has the advantage of having the same thermal conditions during the two loading cycles. Besides high strain rate tests, quasi-static torsional Bauschinger experiments are conducted. The Bauschinger effect at the different strain rates is quantified with a dimensionless Bauschinger stress parameter. It is found that the Bauschinger effect is present at all tested strain rates. However, it is more pronounced at high strain rates. This implies that the kinematic hardening of Ti6Al4V is strain rate sensitive.

  18. MSTor: A program for calculating partition functions, free energies, enthalpies, entropies, and heat capacities of complex molecules including torsional anharmonicity

    Science.gov (United States)

    Zheng, Jingjing; Mielke, Steven L.; Clarkson, Kenneth L.; Truhlar, Donald G.

    2012-08-01

    We present a Fortran program package, MSTor, which calculates partition functions and thermodynamic functions of complex molecules involving multiple torsional motions by the recently proposed MS-T method. This method interpolates between the local harmonic approximation in the low-temperature limit, and the limit of free internal rotation of all torsions at high temperature. The program can also carry out calculations in the multiple-structure local harmonic approximation. The program package also includes six utility codes that can be used as stand-alone programs to calculate reduced moment of inertia matrices by the method of Kilpatrick and Pitzer, to generate conformational structures, to calculate, either analytically or by Monte Carlo sampling, volumes for torsional subdomains defined by Voronoi tessellation of the conformational subspace, to generate template input files, and to calculate one-dimensional torsional partition functions using the torsional eigenvalue summation method. Catalogue identifier: AEMF_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEMF_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 77 434 No. of bytes in distributed program, including test data, etc.: 3 264 737 Distribution format: tar.gz Programming language: Fortran 90, C, and Perl Computer: Itasca (HP Linux cluster, each node has two-socket, quad-core 2.8 GHz Intel Xeon X5560 “Nehalem EP” processors), Calhoun (SGI Altix XE 1300 cluster, each node containing two quad-core 2.66 GHz Intel Xeon “Clovertown”-class processors sharing 16 GB of main memory), Koronis (Altix UV 1000 server with 190 6-core Intel Xeon X7542 “Westmere” processors at 2.66 GHz), Elmo (Sun Fire X4600 Linux cluster with AMD Opteron cores), and Mac Pro (two 2.8 GHz Quad-core Intel Xeon

  19. Evaluation of new technologies for the LISA gravitational reference sensor using the UF torsion pendulum

    Science.gov (United States)

    Conklin, John; Chilton, Andrew; Olatunde, Taiwo; Apple, Stephen; Aitken, Michael; Ciani, Giacomo; Mueller, Guido

    2016-01-01

    The Laser Interferometer Space Antenna (LISA) is the most mature concept for detecting gravitational waves from space. The LISA design has been studied for more than 20 years as a joint effort between NASA and the European Space Agency. LISA consists of three Sun-orbiting spacecraft that form an equilateral triangle, with each side measuring 1-5 million kilometers in length. Each spacecraft houses two free-floating test masses, which are protected from all disturbing forces so that they follow pure geodesics. A single test mass together with its protective housing and associated components is referred to as a gravitational reference sensor. A drag-free control system is supplied with measurements of the test mass position from these sensors and commands external micronewton thrusters to force the spacecraft to fly in formation with the test masses. Laser interferometry is used to measure the minute variations in the distance, or light travel time, between these purely free-falling TMs, caused by gravitational waves. We have constructed a new torsion pendulum facility with a force sensitivity in the range of pN/Hz1/2 around 1 mHz for testing new gravitational reference sensor technologies. This experimental facility consists of a vacuum enclosed torsion pendulum that suspends mock-ups of the LISA test masses, surrounded by their electrode housings. With the aid of this facility, we are (a) developing a novel test mass charge control scheme based on ultraviolet LEDs, (b) examining alternate test mass and electrode housing coatings, and (c) evaluating alternate operational modes of the LISA gravitational reference sensor. This presentation will describe this facility and the development status of these new technologies.

  20. Biomechanical Comparison of Cadaveric and Commercially Available Synthetic Osteoporotic Bone Analogues in a Locked Plate Fracture Model Under Torsional Loading.

    Science.gov (United States)

    Becker, Edward H; Kim, Hyunchul; Shorofsky, Michael; Hsieh, Adam H; Watson, Jeffrey D; OʼToole, Robert V

    2017-05-01

    Biomechanical studies of osteoporotic bone have used synthetic models rather than cadaveric samples because of decreased variability, increased availability, and overall ease of the use of synthetic models. We compared the torsional mechanical properties of cadaveric osteoporotic bone with those of currently available synthetic osteoporotic bone analogues. We tested 12 osteoporotic cadaveric humeri and 6 specimens each of 6 types of synthetic analogues. A 5-mm fracture gap model and posterior plating technique with 4.5-mm narrow 10-hole locking compression plate were used. Torque was applied to a peak of ±10 N·m for 1000 cycles at 0.3 Hz. Data were continuously collected during cyclical and ramped loading with a servohydraulic materials testing system. Cadaveric bone had a 17% failure rate before completing 1000 cycles. Three osteoporotic bone models had 100% failure (P Osteoporotic bone analogues had torsional mechanical properties different from those of osteoporotic cadaveric specimens. The differences between osteoporotic cadaveric humeri and synthetic osteoporotic bone analogues ranged from profound with complete catastrophic failure after a few cycles to subtler differences in stiffness and strain hardening. These findings suggest that different bone analogue models vary substantially in their torsional mechanical properties and might not be appropriate substitutes for cadaveric bone in biomechanical studies of osteoporotic bone.

  1. Computed-tomography-based finite-element models of long bones can accurately capture strain response to bending and torsion.

    Science.gov (United States)

    Varghese, Bino; Short, David; Penmetsa, Ravi; Goswami, Tarun; Hangartner, Thomas

    2011-04-29

    Finite element (FE) models of long bones constructed from computed-tomography (CT) data are emerging as an invaluable tool in the field of bone biomechanics. However, the performance of such FE models is highly dependent on the accurate capture of geometry and appropriate assignment of material properties. In this study, a combined numerical-experimental study is performed comparing FE-predicted surface strains with strain-gauge measurements. Thirty-six major, cadaveric, long bones (humerus, radius, femur and tibia), which cover a wide range of bone sizes, were tested under three-point bending and torsion. The FE models were constructed from trans-axial volumetric CT scans, and the segmented bone images were corrected for partial-volume effects. The material properties (Young's modulus for cortex, density-modulus relationship for trabecular bone and Poisson's ratio) were calibrated by minimizing the error between experiments and simulations among all bones. The R(2) values of the measured strains versus load under three-point bending and torsion were 0.96-0.99 and 0.61-0.99, respectively, for all bones in our dataset. The errors of the calculated FE strains in comparison to those measured using strain gauges in the mechanical tests ranged from -6% to 7% under bending and from -37% to 19% under torsion. The observation of comparatively low errors and high correlations between the FE-predicted strains and the experimental strains, across the various types of bones and loading conditions (bending and torsion), validates our approach to bone segmentation and our choice of material properties. Copyright © 2011 Elsevier Ltd. All rights reserved.

  2. Torsion of the fallopian the mimicking appendicitis in a pregnant woman; Torsion de la trompa de Falopio en una mujer gestante simulando apendicitis

    Energy Technology Data Exchange (ETDEWEB)

    Tapia-Vine, M.; Pedrosa, I.; Escribano, N. [Hospital Clinico San Carlos (Spain)

    2000-07-01

    Isolated torsion of the fallopian tube is an uncommon entity. Given the difficulties involved in the preoperative diagnosis, the ultrasound findings characteristic of this anomaly are not widely known. We present a case of tubal torsion associated with a cyst, describing the ultrasound images in our case and those reported in the literature. (Author) 18 refs.

  3. A new insole measurement system to detect bending and torsional moments at the human foot during footwear condition: a technical report.

    Science.gov (United States)

    Stief, Thomas; Peikenkamp, Klaus

    2015-01-01

    Stress occurring at the feet while wearing footwear is often determined using pressure measurement systems. However, other forms of stress, such as bending, torsional and shear loadings, cannot be detected in shoes during day-to-day activities. Nevertheless, the detection of these types of stresses would be helpful for understanding the mechanical aspects of various kinds of hard and soft tissue injuries. Therefore, we describe the development of a new measuring device that allows the reliable determination of bending and torsional load at the foot in shoes. The system consists of a measuring insole and an analogue device with Bluetooth interface. The specific shape of the insole base layer, the positions of the strain gauges, and the interconnections between them have all been selected in such a way so as to isolate bending and torsional moment detections in the medial and lateral metatarsal region. The system was calibrated using a classical two-point test procedure. A single case study was executed to evaluate the new device for practical use. This application consisted of one subject wearing neutral shoes walking on a treadmill. The calibration results (coefficients of determination R(2) > 0.999) show that bending and torsional load can be reliably detected using the measurement system presented. In the single case study, alternating bending and torsional load can be detected during walking, and the shape of the detected bending moments can be confirmed by the measurements of Arndt et al. (J Biomech 35:621-8, 2002). Despite some limitations, the presented device allows for the reliable determination of bending and torsional stresses at the foot in shoes.

  4. Testicular torsion and weather conditions: analysis of 21,289 cases in Brazil

    Directory of Open Access Journals (Sweden)

    Fernando Korkes

    2012-04-01

    Full Text Available PURPOSE: The hypothesis of association between testicular torsion and hyperactive cremasteric reflex, worsened by cold weather, has not been proved. Thirteen studies in the literature evaluated this issue, with inconclusive results. The aim of the present study was to evaluate the seasonality of testicular torsion in a large subset of patients surgically treated in Brazil, and additionally to estimate the incidence of testicular torsion. MATERIALS AND METHODS: Brazilian Public Health System Database was assessed from 1992-2010 to evaluate hospital admissions associated with treatment of testicular torsion. Average monthly temperature between 1992-2010 was calculated for each region. RESULTS: We identified 21,289 hospital admissions for treatment of testicular torsion. There was a higher number of testicular torsions during colder months (p = 0.002. To estimate the incidence of testicular torsion, we have related our findings to data from the last Brazilian census (2010. In 2010, testicular torsion occurred in 1.4:100,000 men in Brazil. CONCLUSIONS:Testicular torsion occurred at an annual incidence of approximately 1.4:100,000 men in Brazil in 2010. Seasonal variations do occur, with a significant increase of events during winter. Our findings support the theory of etiological role of cold weather to the occurrence of testicular torsion. Strategies to prevent these events can be based on these findings.

  5. Experimental evaluation of torsional fatigue strength of welded bellows and application to design of fusion device

    International Nuclear Information System (INIS)

    Takatsu, Hideyuki; Yamamoto, Masahiro; Shimizu, Masatsugu; Suzuki, Kazuo; Sonobe, Tadashi; Hayashi, Yuzo; Mizuno, Gen-ichiro.

    1984-01-01

    Torsional fatigue strength of the welded bellows was evaluated experimentally, aiming the application to a port of a fusion device. The welded bellows revealed elastic torsional buckling and spiral distorsion even under a small angle of torsion. Twisting load never leads the welded bellows to fracture easily so far as the angle of torsion is not excessively large, and the welded bellows has the torsional fatigue strength much larger than that expected so far. Two formulae were proposed to evaluate the stress of the welded bellows under the forced angle of torsion; shearing stress evaluation formula in the case that torsional buckling does not occur and the axial bending stress evaluation formula in the case that torsional buckling occurs. And the results of the torsional fatigue experiments showed that the former is reasonably conservative and simulates the actual behavior of the welded bellows better than the latter in the high cycle fatigue region and vice versa in the low cycle fatigue region from the viewpoint of the mechanical design. The present evaluation method of the torsional fatigue strength was applied to the welded bellows for the port of the JT-60 vacuum vessel and its structural integrity was confirmed under the design load condition. (author)

  6. A study of white etching crack formation by compression-torsion experiments

    Directory of Open Access Journals (Sweden)

    S. Averbeck

    2016-10-01

    Full Text Available In this study, an attempt was made to recreate the bearing damage phenomenon “White Etching Cracks” with a simplified testing setup. Rolling contact fatigue conditions were simulated with in-phase and out-ofphase cyclic compression-torsion experiments on 100Cr6 steel specimens. The results are compared in terms of microstructural change. Focused Ion Beam and metallographic analysis reveal that a fine-grained, white etching zone formed in the vicinity of the fatigue cracks of specimens tested with the in-phase load pattern. In contrast, no such structures were found after testing the out-of-phase load pattern. The properties of the white etching zone are characterised in more detail and compared with White Etching Cracks

  7. Omental torsion in a captive polar bear (Ursus maritimus).

    Science.gov (United States)

    Mendez-Angulo, Jose L; Funes, Francisco J; Trent, Ava M; Willette, Michelle; Woodhouse, Kerry; Renier, Anna C

    2014-03-01

    This is the first case report of an omental torsion in a polar bear (Ursus maritimus). A captive, 23-yr-old, 250-kg, intact female polar bear presented to the University of Minnesota Veterinary Medical Center with a 2-day history of lethargy, depression, and vomiting. Abdominal ultrasound identified large amounts of hyperechoic free peritoneal fluid. Ultrasound-guided abdominocentesis was performed and yielded thick serosanguinous fluid compatible with a hemoabdomen. An exploratory laparotomy revealed a large amount of malodorous, serosanguineous fluid and multiple necrotic blood clots associated with a torsion of the greater omentum and rupture of a branch of the omental artery. A partial omentectomy was performed to remove the necrotic tissue and the abdomen was copiously lavaged. The polar bear recovered successfully and is reported to be clinically well 6 mo later. This condition should be considered as a differential in bears with clinical signs of intestinal obstruction and hemoabdomen.

  8. Coupled Torsional and Bending Vibrations of Actively Controlled Drillstrings

    Science.gov (United States)

    YIGIT, A. S.; CHRISTOFOROU, A. P.

    2000-06-01

    The dynamics of actively controlled drillstrings is studied. The equations of motion are derived using a lumped parameter model in which the coupling between torsional and bending vibrations is considered. The model also includes the dynamics of the rotary drive system which contains the rotary table, the gearbox and an armature controlled DC motor. The interactions between the drillstring and the borehole which are considered, include the impacts of collars with the borehole wall as well as bit rotation-dependent weight and torque on bit (WOB and TOB). Simulation results obtained by numerically solving the equations of motion are in close qualitative agreement with field and laboratory observations regarding stick-slip oscillations. A linear quadratic regulator (LQR) controller is designed based on a linearized model and is shown to be effective in eliminating this type of oscillations. It is also shown that for some operational parameters the control action may excite large bending vibrations due to coupling with the torsional motion.

  9. Torsion of a Wandering Spleen Presenting as Acute Abdomen

    International Nuclear Information System (INIS)

    Chauhan, Narvir Singh; Kumar, Satish

    2016-01-01

    Wandering spleen is a rare condition which if uncorrected, can result in torsion and infarction. Clinical presentation of a wandering spleen can vary from asymptomatic abdominal mass to acute abdominal pain. Radiological investigations play a pivotal role in diagnosis as the clinical diagnosis is usually impossible. We present a case of wandering spleen with torsion and complete infarction that occurred in a 32-year-old multiparous female. The diagnosis was established preoperatively on colour Doppler and CT of the abdomen with subsequent confirmation on surgery. Wandering spleen is a rare clinical condition which can present as acute abdomen. An increased awareness of this entity together with the timely use of ultrasound and CT of the abdomen can play an important role in preoperative diagnosis and surgical management

  10. Longitudinal and torsional vibrations in rotors with transverse cracks

    International Nuclear Information System (INIS)

    Theis, W.

    1990-01-01

    In a rotating shaft with a crack, the bending, longitudinal and torsional degrees of freedom are linked. This paper presents a crack model which for the first time takes all six beam degrees of freedom into account for the open crack. The statements lead to a finite rigidity matrix and a transition matrix for a crack beam element. The model concepts known to date can be consistently generated as special cases from the new crack model. Depending on the motion condition, equations of motion with non-linear or periodically time-variant character are obtained. The longitudinal and torsional vibration behaviour under weight-dominant conditions are examined more intensively with the example of a large turbine. It is shown that the vibration components in harmony with the rotation can be used to identify the location and depth of the crack. (orig.) With 88 figs [de

  11. TORSIONAL DEFORMATION AND FATIGUE BEHAVIOUR OF 6061 ALUMINIUM ALLOY

    Directory of Open Access Journals (Sweden)

    marini marno

    2012-02-01

    Full Text Available Torsional deformation and fatigue behaviour of both solid and thin-walled tubular specimens were made from as-received and heat treated 6061 aluminium alloy were studied. 6061 aluminium alloy have been widely used as a candidate material in automobile, aerospace, aircraft and structural application because of their superior mechanical properties such as high strength to weight ratio, good ductility and others. The differences in cyclic deformation and fatigue behaviours between round and solid specimens where a stress gradient exist, and thin-walled tubular specimens where a uniform stress state is commonly assumed, are also discussed. Von Mises and Tresca criteria has been used to predict the monotonic and cyclic deformation curve and compared to the torsional data obtained from the experiment. The S-N curve was used to present and evaluate the fatigue life of the specimens. Through fractographic analysis, failure criteria of fracture surfaces were observed and discussed. 

  12. The Torsion of Members Having Sections Common in Aircraft Construction

    Science.gov (United States)

    Trayer, George W; March, H W

    1930-01-01

    Within recent years a great variety of approximate torsion formulas and drafting-room processes have been advocated. In some of these, especially where mathematical considerations are involved, the results are extremely complex and are not generally intelligible to engineers. The principal object of this investigation was to determine by experiment and theoretical investigation how accurate the more common of these formulas are and on what assumptions they are founded and, if none of the proposed methods proved to be reasonable accurate in practice, to produce simple, practical formulas from reasonably correct assumptions, backed by experiment. A second object was to collect in readily accessible form the most useful of known results for the more common sections. Formulas for all the important solid sections that have yielded to mathematical treatment are listed. Then follows a discussion of the torsion of tubular rods with formulas both rigorous and approximate.

  13. MR evaluation of femoral neck version and tibial torsion

    International Nuclear Information System (INIS)

    Koenig, James Karl; Dwek, Jerry R.; Pring, Maya E.

    2012-01-01

    Abnormalities of femoral neck version have been associated with a number of hip abnormalities in children, including slipped capital femoral epiphysis, proximal femoral focal deficiency, coxa vara, a deep acetabulum and, rarely, developmental dysplasia of the hip. Orthopedic surgeons also are interested in quantifying the femoral neck anteversion or retroversion in children especially to plan derotational osteotomies. Historically, the angle of femoral version and tibial torsion has been measured with the use of radiography and later by CT. Both methods carry with them the risks associated with ionizing radiation. Techniques that utilize MR are used less often because of the associated lengthy imaging times. This article describes a technique using MRI to determine femoral neck version and tibial torsion with total scan times of approximately 10 min. (orig.)

  14. In vitro transcription of a torsionally constrained template

    DEFF Research Database (Denmark)

    Bentin, Thomas; Nielsen, Peter E

    2002-01-01

    of torsionally constrained DNA by free RNAP. We asked whether or not a newly synthesized RNA chain would limit transcription elongation. For this purpose we developed a method to immobilize covalently closed circular DNA to streptavidin-coated beads via a peptide nucleic acid (PNA)-biotin conjugate in principle......RNA polymerase (RNAP) and the DNA template must rotate relative to each other during transcription elongation. In the cell, however, the components of the transcription apparatus may be subject to rotary constraints. For instance, the DNA is divided into topological domains that are delineated...... constrained. We conclude that transcription of a natural bacterial gene may proceed with high efficiency despite the fact that newly synthesized RNA is entangled around the template in the narrow confines of torsionally constrained supercoiled DNA....

  15. Quartz crystal microbalance based on torsional piezoelectric resonators

    International Nuclear Information System (INIS)

    Buecking, W.; Du, B.; Turshatov, A.; Koenig, A. M.; Reviakine, I.; Bode, B.; Johannsmann, D.

    2007-01-01

    A quartz crystal microbalance (QCM) is described, which is based on a torsional resonator, rather than a conventional thickness-shear resonator. Typical applications are measurements of film thickness in the coating industry and monitoring of biofouling. The torsional QCM is about a factor of 100 less sensitive than the conventional QCM. On the other hand, it can probe film thicknesses in the range of hundreds of microns, which is impossible with the conventional QCM due to viscoelastic artifacts. Data acquisition and data analysis proceed in analogy to the conventional QCM. An indicator of the material's softness can be extracted from the bandwidth of the resonance. Within the small-load approximation, the frequency shift is independent of whether the sample is applied to the face or to the side of the cylinder. Details of the geometry matter if the viscoelastic properties of the sample are of interest

  16. A torsional artificial muscle from twisted nitinol microwire

    Science.gov (United States)

    Mirvakili, Seyed M.; Hunter, Ian W.

    2017-04-01

    Nitinol microwires of 25 μm in diameter can have tensile actuation of up to 4.5% in less than 100 ms. A work density of up to 480 MPa can be achieved from these microwires. In the present work, we are showing that by twisting the microwires in form of closed-loop two-ply yarn we can create a torsional actuator. We achieved a revisable torsional stroke of 46°/mm with peak rotational speed of up to 10,000 rpm. We measured a gravimetric torque of up to 28.5 N•m/kg which is higher than the 3 - 6 N•m/kg for direct-drive commercial electric motors. These remarkable performance results are comparable to those of guest-infiltrated carbon nanotube twisted yarns.

  17. Secondary torsion of vermiform appendix with mesoappendiceal lipoma.

    Science.gov (United States)

    Grebic, Damir; Lovasic, Franjo; Benjak, Indira; Lovasic, Ingrid

    2015-01-01

    A torsion of the vermiform appendix with a mesoappendiceal lipoma is a rare condition. It is also a rare cause of acute abdomen, as such, the condition is diagnosed during surgery. This case report presents a 70-year-old male patient with lower right abdominal pain and signs of acute abdomen with an increased peripheral blood leukocyte count. An ultrasound examination revealed a mass of 9.6 cm2, which was suggested to be a perityphlitic abscess. An emergency operation was indicated, as the patient had clinical signs of acute abdomen. Laparotomy via a pararectal incision revealed the cause of the pain to be a torsion of the vermiform appendix caused by a mesoappendiceal lipoma. The apex of the appendix was perforated, which caused circumscript peritonitis. Both an appendectomy and an extirpation of the tumor were performed, and a surgical drain was placed in the wound, yielding an excellent postoperative clinical outcome.

  18. Global aspects of symmetries in sigma models with torsion

    International Nuclear Information System (INIS)

    Papadopoulos, G.; Imperial Coll. of Science and Technology, London

    1994-07-01

    It is shown that non-trivial topological sectors can prevent the quantum mechanical implementation of the symmetries of the classical field equations of sigma models with torsion. The associated anomaly is computed, and it is shown that it depends on the homotopy class of the topological sector of the theory and the group action on the sigma model manifold that generates the symmetries of the classical field equations. (orig.)

  19. Calibration of combined bending-torsion fatigue reliability data reduction

    Science.gov (United States)

    Kececioglu, D.; Mcconnell, J. B.

    1969-01-01

    The combined bending-torsion fatigue reliability research machines are described. Three such machines are presently in operation. The calibration of these machines is presented in depth. Fatigue data generated with these machines for SAE 4340 steel grooved specimens subjected to reversed bending and steady torque loading are given. The data reduction procedure is presented. Finally, some comments are made about notch sensitivity and stress concentration as applied to combined fatigue.

  20. Portal Venous Thrombosis Developing after Torsion of a Wandering ...

    African Journals Online (AJOL)

    2017-03-06

    Mar 6, 2017 ... L, Mullineris B, et al. Laparoscopic transperitoneal left adrenalectomy and wandering spleen risk. JSLS 2014:18-pii: e2014.00278. 5. Koca B, Çınar H, İA Tarım, Güngör BB. Torsion of the wandering spleen: A rare case of acute abdominal causing. Gulhane Med J 2013;55:51-53. 6. Herman TE, Siegel MJ.

  1. Torsional Elastic Property Measurements of Selected Orthodontic Archwires.

    Science.gov (United States)

    1987-01-01

    properties of denture base acrylics . 26 In this experiment, an inverted pendulum was hung by a fine, fixed wire. The amplitude and frequency of...of Polymers. Polymer Engineering and Science 19:664-675. 26. Braden M, Stafford GD: Viscoelastic Properties of Some Denture Base Materials. J Dent...D-AiB5 669 TORSIONAL ELASTIC PROPERTY MEASUREMENTSO SLECE ORTHODONTIC ARCHWlIRES(U) AIR FORCE INST OF TECH WRIGHT-PATTERSON AFB OH B E LARSON 1987

  2. On Polya's inequality for torsional rigidity and first Dirichlet eigenvalue

    OpenAIRE

    Berg, M. van den; Ferone, V.; Nitsch, C.; Trombetti, C.

    2016-01-01

    Let $\\Omega$ be an open set in Euclidean space with finite Lebesgue measure $|\\Omega|$. We obtain some properties of the set function $F:\\Omega\\mapsto \\R^+$ defined by $$ F(\\Omega)=\\frac{T(\\Omega)\\lambda_1(\\Omega)}{|\\Omega|} ,$$ where $T(\\Omega)$ and $\\lambda_1(\\Omega)$ are the torsional rigidity and the first eigenvalue of the Dirichlet Laplacian respectively. We improve the classical P\\'olya bound $F(\\Omega)\\le 1,$ and show that $$F(\\Omega)\\le 1- \

  3. Ultrahigh torsional stiffness and strength of boron nitride nanotubes.

    Science.gov (United States)

    Garel, Jonathan; Leven, Itai; Zhi, Chunyi; Nagapriya, K S; Popovitz-Biro, Ronit; Golberg, Dmitri; Bando, Yoshio; Hod, Oded; Joselevich, Ernesto

    2012-12-12

    We report the experimental and theoretical study of boron nitride nanotube (BNNT) torsional mechanics. We show that BNNTs exhibit a much stronger mechanical interlayer coupling than carbon nanotubes (CNTs). This feature makes BNNTs up to 1 order of magnitude stiffer and stronger than CNTs. We attribute this interlayer locking to the faceted nature of BNNTs, arising from the polarity of the B-N bond. This property makes BNNTs superior candidates to replace CNTs in nanoelectromechanical systems (NEMS), fibers, and nanocomposites.

  4. Compactification over coset spaces with torsion and vanishing cosmological constant

    International Nuclear Information System (INIS)

    Batakis, N.A.

    1989-01-01

    We consider the compactification of ten-dimensional Einstein-Yang-Mills theories over non-symmetric, six-dimensional homogeneous coset spaces with torsion. We examine the Einstein-Yang-Mills equations of motion requiring vanishing cosmological constant at ten and four dimensions and we present examples of compactifying solutions. It appears that the introduction of more than one radii in the coset space, when possible, may be mandatory for the existence of compactifying solutions. (orig.)

  5. Compactification over coset spaces with torsion and vanishing cosmological constant

    Energy Technology Data Exchange (ETDEWEB)

    Batakis, N.A.; Farakos, K.; Koutsoumbas, G.; Zoupanos, G.; Kapetanakis, D.

    1989-04-13

    We consider the compactification of ten-dimensional Einstein-Yang-Mills theories over non-symmetric, six-dimensional homogeneous coset spaces with torsion. We examine the Einstein-Yang-Mills equations of motion requiring vanishing cosmological constant at ten and four dimensions and we present examples of compactifying solutions. It appears that the introduction of more than one radii in the coset space, when possible, may be mandatory for the existence of compactifying solutions.

  6. Elasto-plastic torsion problem as an infinity Laplace's equation

    Directory of Open Access Journals (Sweden)

    Ahmed Addou

    2006-12-01

    Full Text Available In this paper, we study a perturbed infinity Laplace's equation, the perturbation corresponds to an Leray-Lions operator with no coercivity assumption. We consider the case where data are distributions or $L^{1}$ elements. We show that this problem has an unique solution which is the solution to the variational inequality arising in the elasto-plastic torsion problem, associated with an operator $A$.

  7. Torsion and curvature in higher dimensional supergravity theories

    International Nuclear Information System (INIS)

    Smith, A.W.; Pontificia Univ. Catolica do Rio de Janeiro

    1983-01-01

    This work is an extension of Dragon's theorems to higher dimensional space-time. It is shown that the first set of Bianchi identities allow us to express the curvature components in terms of torsion components and its covariant derivatives. It is also shown that the second set of Bianchi identities does not give any new information which is not already contained in the first one. (Author) [pt

  8. Mechanical behavior of Fe{sub 75}Mo{sub 5}P{sub 10}C{sub 7.5}B{sub 2.5} bulk-metallic glass under torsional loading

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Xinjian [School of Chemical Engineering and Technology, Tianjin University, 92 Weijin Road, Tianjin 300072 (China); Huang Lu [Department of Materials Science and Engineering, University of Tennessee, TN 37996 (United States); Key Laboratory of Aerospace Materials and Performance (Ministry of Education), School of Materials Science and Engineering, Beijing University of Aeronautics and Astronautics, Beijing 100191 (China); Chen Xu, E-mail: xchen@tju.edu.cn [School of Chemical Engineering and Technology, Tianjin University, 92 Weijin Road, Tianjin 300072 (China); Liaw, Peter K. [Department of Materials Science and Engineering, University of Tennessee, TN 37996 (United States); An Ke [Neutron Scattering Sciences Division, Oak Ridge National Laboratory, TN 37831 (United States); Zhang Tao [Key Laboratory of Aerospace Materials and Performance (Ministry of Education), School of Materials Science and Engineering, Beijing University of Aeronautics and Astronautics, Beijing 100191 (China); Wang Gongyao [Department of Materials Science and Engineering, University of Tennessee, TN 37996 (United States)

    2010-11-15

    Research highlights: {yields} Fe{sub 75}Mo{sub 5}P{sub 10}C{sub 7.5}B{sub 2.5} bulk-metallic glass exhibits a brittle characteristic under torsional loading. {yields} The BMG occurs in a tensile mode failure under torsional loading. {yields} A slight cyclic-hardening behavior was observed in the initial loading cycles during torsional-fatigue tests. {yields} The torsional fatigue-fracture surface consists of three main regions. - Abstract: Pure- and cyclic-torsional studies were conducted on a Fe{sub 75}Mo{sub 5}P{sub 10}C{sub 7.5}B{sub 2.5} (atomic percent, at.%) bulk-metallic glass at room temperature for an understanding of its damage and fracture mechanisms. Under pure-torsional loading, the metallic glass exhibited very little plastic strain before fracture. The fracture initiated along the maximum tensile-stress plane, which is about 45{sup o} to the axial direction. The shear-fracture strength ({approx}510 MPa) is much lower than the compressive-fracture strength ({approx}3280 MPa), which suggests that different deformation mechanisms be present under various loading modes. Instead of an apparent vein-type structure, the fracture morphologies revealed a crack-initiation site, a mirror region, a mist region, and a hackle region. Under cyclic-torsional loading, fatigue cracks initiated from casting defects, and propagate generally along the maximum tensile-stress plane. A slight cyclic-hardening behavior was observed in initial loading steps. The fatigue-fracture surface consists of three main regions: the fatigue crack-initiation, crack-propagation, and final-fast-fracture areas. The striations resulting from the blunting and re-sharpening of the fatigue crack tip were observed in the crack-propagation region. Based on these results, the damage and fracture mechanisms of the metallic glass induced by torsional loadings are elucidated.

  9. Torsion Property of the Structure Bonded Aluminum Foam Due to Impact

    Directory of Open Access Journals (Sweden)

    Hwang G.W.

    2017-06-01

    Full Text Available An aluminum foam added with foaming agent, is classified into an open-cell type for heat transfer and a closed-cell type for shock absorption. This study investigates the characteristic on the torsion of aluminum foam for a closed-cell type under impact. The fracture characteristics are investigated through the composite of five types of aluminum foam (the thicknesses of 25, 35, 45, 55 and 65 mm, when applying the torsional moment of impact energy on the junction of a porous structure attached by an adhesive. When applying the impact energy of 100, 200 and 300J, the aluminum foams with thicknesses of 25 mm and 35 mm broke off under all conditions. For the energy over 200J, aluminums thicker than 55 mm continued to be attached. Furthermore, the aluminum specimens with thicknesses of 55 mm and 65 mm that were attached with more than 30% of bonding interface remained, proving that they could maintain bonding interface against impact energy. By comparing the data based on the analysis and test result, an increase in the thickness of specimen leads to the plastic deformation as the stress at the top and bottom of bonding interface moves to the middle by spreading the stress horizontally. Based on this fracture characteristic, this study can provide the data on the destruction and separation of bonding interface and may contribute to the safety design.

  10. Direct Design of T-Beams for Combined Load of Bending and Torsion

    Directory of Open Access Journals (Sweden)

    A. S. Alnuaimi

    2007-12-01

    Full Text Available Tests were conducted on five reinforced concrete T-beams subjected to combined load of bending and torsion. Elastic stress field in conjunction with Nielsen's 2D yield criterion for reinforced concrete subjected to in-plane forces were used in the Direct Design Method for the design of reinforcement. The beam dimensions were: flange width = 600mm, flange thickness = 150mm, web width = 200mm, total depth = 600mm and beam length = 5.2m. Required reinforcement calculated using the Direct Design Method was compared with the ACI and BSI codes. It was found that the Direct Design Method requires longitudinal reinforcement similar to the ACI code but less than the BSI code. In the transverse direction, the Direct Design Method requires much less reinforcement than both codes. The main variable studied was the ratio of the maximum twisting moment to the bending moment which was varied between 0.6 and 1.5. Good agreement was found between the design and experimental failure loads. Most of the longitudinal and transverse steel yielded or reached near yield stress when the design load was approached. All beams failed near the design loads and undergone ductile behaviour until failure. The results indicate that the Direct Design Method can be successfully used to design reinforced concrete T-beams for the combined effect of bending and torsion loads.

  11. Left ventricular torsion and circumferential strain responses to exercise in patients with ischemic coronary artery disease.

    Science.gov (United States)

    Peteiro, Jesus; Bouzas-Mosquera, Alberto; Broullon, Javier; Sanchez-Fernandez, Gabriel; Barbeito, Cayetana; Perez-Cebey, Lucia; Martinez, Dolores; Vazquez-Rodriguez, Jose M

    2017-01-01

    LV torsion during exercise in patients with coronary artery disease (CAD) is not well known. Circumferential strain (CS) and left ventricular (LV) torsion (Tor) have not been evaluated during ischemia in these patients. We aimed to assess the effect of ischemia during exercise echocardiography (ExE) on CS and Tor. We studied a group of 73 patients with true positive ExE results (Ischemic group: ischemia plus an abnormal coronary angiogram) and a matched control group of 66 patients with negative ExE and either normal coronary angiography or low post-test probability of CAD. Basal rotation (Rot) and apical rotation and basal and apical CS were studied by speckle tracking at rest and exercise. Apical CS and apical and basal Rot values were similar between groups at rest, except basal CS which was already worse in the ischemic group. At exercise, all rotational and CS parameters were impaired in the ischemic in comparison with the control group (basal CS: -18 ± 5 vs. -25 ± 7 %, p exercise-induced ischemia. LV-Tor decreases with ischemia due to worsening of basal rotation, whereas apical rotation does not impair, suggesting the existence of an apical compensatory mechanism.

  12. Review of gastric torsion in eight guinea pigs (Cavia porcellus).

    Science.gov (United States)

    Nógrádi, Anna Linda; Cope, Iain; Balogh, Márton; Gál, János

    2017-12-01

    The authors present eight cases of gastric dilatation and volvulus (GDV) in guinea pigs from the Department and Clinic of Exotic Animal and Wildlife Medicine, University of Veterinary Medicine, Budapest, Hungary between 2012 and 2016. Seven animals were operated on and two survived. Gastric torsion has been noted in many mammalian species. Gastric volvulus has a high morbidity and high mortality rate with a guarded to poor prognosis in all of these species. How GDV develops is still not widely understood. Postmortem examinations, in both our cases and previously reported cases, have failed to reveal the exact causes of the gastric torsions. The aetiology of gastric torsion in guinea pigs is probably multifactorial. Feeding fewer meals per day, eating rapidly, decreased food particle size, exercise, stress after a meal, competition, age, and an aggressive or fearful temperament, are all likely and potential risk factors for GDV development in a similar fashion to dogs. Sex, breeding, dental diseases, anatomical abnormalities, pain and pregnancy may also be contributing factors.

  13. Stresses and strains under torsion of polymeric parts

    Directory of Open Access Journals (Sweden)

    Kulyk T.I.

    2016-12-01

    Full Text Available The article is devoted to the determination of stress arising during deformation of polymeric parts, namely, under torsion. Analytical methods with a graphical representation of are used in the paper. Because the elastic properties of polymeric materials do not obey Hooke's law, the use of classical methods of applied mechanics for description of such parts leads to errors in calculation results. The process of deformation of polymeric beams under torsion is analyzed. The mathematical model is evolved to describe the process of torsion of solid and hollow beams of circular cross section. The expressions for shear stress distribution along the radius of the beam and calculating the angle of twist of beam’s sections under torque are obtained, given the nature of dependence between strains and stresses for the polymeric material. Graphic dependencies are built, showing the results of calculation of shear stresses and deformations of beams at different values of torque. The mathematical model is built using a power relationship between stress and deformation of the polymer material. The results can be used for the design of structural elements of machines and appliances, building constructions, products of light industry.

  14. On discrete symmetries and torsion homology in F-theory

    Energy Technology Data Exchange (ETDEWEB)

    Mayrhofer, Christoph [Arnold-Sommerfeld-Center, Ludwig-Maximilians-Universität München,München (Germany); Palti, Eran; Till, Oskar; Weigand, Timo [Institut für Theoretische Physik, Ruprecht-Karls-Universität Heidelberg,Heidelberg (Germany)

    2015-06-04

    We study the relation between discrete gauge symmetries in F-theory compactifications and torsion homology on the associated Calabi-Yau manifold. Focusing on the simplest example of a ℤ{sub 2} symmetry, we show that there are two physically distinct ways that such a discrete gauge symmetry can arise. First, compactifications of M-Theory on Calabi-Yau threefolds which support a genus-one fibration with a bi-section are known to be dual to six-dimensional F-theory vacua with a ℤ{sub 2} gauge symmetry. We show that the resulting five-dimensional theories do not have a ℤ{sub 2} symmetry but that the latter emerges only in the F-theory decompactification limit. Accordingly the genus-one fibred Calabi-Yau manifolds do not exhibit torsion in homology. Associated to the bi-section fibration is a Jacobian fibration which does support a section. Compactifying on these related but distinct varieties does lead to a ℤ{sub 2} symmetry in five dimensions and, accordingly, we find explicitly an associated torsion cycle. We identify the expected particle and membrane system of the discrete symmetry in terms of wrapped M2 and M5 branes and present a field-theory description of the physics for both cases in terms of circle reductions of six-dimensional theories. Our results and methods generalise straightforwardly to larger discrete symmetries and to four-dimensional compactifications.

  15. Experimental and Simulation Studies of Strength and Fracture Behaviors of Wind Turbine Bearing Steel Processed by High Pressure Torsion

    Directory of Open Access Journals (Sweden)

    Ning Wang

    2016-12-01

    Full Text Available White structure flaking (WSF has been found to be one of the failure modes in bearing steels under rolling contacts through the formation of cracks associated with a microstructural change called white etching area (WEA. In the present research, the effects of the high-pressure torsion (HPT process on the microstructure and mechanical properties of an AISI 52100 alloy are studied. An annealed AISI 52100 was subjected to high-pressure torsion at room temperature under a pressure of up to ~6 GPa for up to three turns. Finite-element modeling (FEM was used to simulate the process under high-pressure torsion and quasi-constrained conditions to reveal the material property changes occurring in HPT. Scanning electron microscopy and microhardness testing after processing were used to investigate the microstructural and mechanical property evolution of the steel. Strain induced microstructural transformations occur and affect the mechanical properties in a similar way to the well-known white etching area (WEA found beneath the surface of wind turbine bearings. Here, HPT is used to study the feasibility of creating microstructural changes that are similar to WEA. This paper presents the preliminary results of using HPT to produce WEAs.

  16. Research on torsional vibration modelling and control of printing cylinder based on particle swarm optimization

    Science.gov (United States)

    Wang, Y. M.; Xu, W. C.; Wu, S. Q.; Chai, C. W.; Liu, X.; Wang, S. H.

    2018-03-01

    The torsional oscillation is the dominant vibration form for the impression cylinder of printing machine (printing cylinder for short), directly restricting the printing speed up and reducing the quality of the prints. In order to reduce torsional vibration, the active control method for the printing cylinder is obtained. Taking the excitation force and moment from the cylinder gap and gripper teeth open & closing cam mechanism as variable parameters, authors establish the dynamic mathematical model of torsional vibration for the printing cylinder. The torsional active control method is based on Particle Swarm Optimization(PSO) algorithm to optimize input parameters for the serve motor. Furthermore, the input torque of the printing cylinder is optimized, and then compared with the numerical simulation results. The conclusions are that torsional vibration active control based on PSO is an availability method to the torsional vibration of printing cylinder.

  17. A Study of the Preload Force in Metal-Elastomer Torsion Springs

    Directory of Open Access Journals (Sweden)

    Sikora Wojciech

    2016-12-01

    Full Text Available Neidhart type suspension units composed of metal-elastomer torsion springs can be a good alternative to steel helical springs in applications such as vibration absorbers or vehicle suspension systems. Assembling this type of spring requires initial preload of the elastomeric working elements, which determines their operating properties. The results of experimental tests and numerical simulations concerning the preload of elastomeric working elements in Neidhart type suspension units are presented in the paper. The performed research made it possible to propose a new calculation model for determining the preload force value acting on the elastomeric cylindrical elements applied in this type of suspension unit. The results obtained using the proposed model exhibit good convergence with FEM simulation results within the range of the tested geometrical and material properties.

  18. Success of torsional correction surgery after failed surgeries for patellofemoral pain and instability

    OpenAIRE

    Stevens, Peter M.; Gililland, Jeremy M.; Anderson, Lucas A.; Mickelson, Jennifer B.; Nielson, Jenifer; Klatt, Joshua W.

    2013-01-01

    Torsional deformities of the femur and/or tibia often go unrecognized in adolescents and adults who present with anterior knee pain, and patellar maltracking or instability. While open and arthroscopic surgical techniques have evolved to address these problems, unrecognized torsion may compromise the outcomes of these procedures. We collected a group of 16 consecutive patients (23 knees), with mean age of 17, who had undergone knee surgery before torsion was recognized and subsequently treate...

  19. 3D Curves With a Prescribed Curvature and Torsion for a Flying Robot

    International Nuclear Information System (INIS)

    Bestaoui, Yasmina

    2008-01-01

    The objective of this paper is to generate a desired flight path to be followed by an flying robot. A curve with discontinuous curvature and torsion is not appropriate for smooth motions for any vehicle architecture. Three different classes of curves are presented. First, constant curvature and torsion followed by a linear variation versus the curvilinear abscissa then a quadratic variation. Finally, the problem of maneuvers between two trim helices of different curvature and torsion is tackled with

  20. Appendiceal torsion associated with undescended caecum: a case report and review of the literature

    Science.gov (United States)

    Dimitriadis, Panagiotis A; Makar, Ragai R; Randall, Jon K; Ramus, James

    2012-01-01

    Torsion of the vermiform appendix is a rare disorder that causes symptoms similar to those of acute appendicitis. Primary and secondary causes of appendiceal torsion have been reported in the literature. Laparoscopy appears to be the most appropriate modality for diagnosis and treatment where the condition is suspected. To our knowledge this is the first case of appendiceal torsion in an adult causing right upper quadrant pain related to caecal malposition. PMID:23010467

  1. Unusual cause of acute abdominal pain in a postmenopausal woman: adnexal torsion

    Directory of Open Access Journals (Sweden)

    Alper Biler

    2016-03-01

    Full Text Available Adnexal torsion is an infrequent but significant cause of acute lower abdominal pain in women. While adnexal torsion is generally considered in premenopausal women presenting with acute abdominal pain and a pelvic mass, it is a rare cause of acute abdominal pain during postmenopausal period. The diagnosis of adnexal torsion is often challenging due to nonspesific clinical, laboratory and physical examination findings. Causes of adnexal torsion is also different in premenopausal and postmenopausal women. While a simple functional cyst is often the cause of torsion in premenopausal women, it is more rarely the cause in postmenopausal women. Adnexal torsion is a surgical emergency. The surgery of adnexal torsion is performed either via conventional exploratory laparotomy or laparoscopic surgery. Adnexal torsion in postmenopausal women should be considered not only in the setting of sudden onset pain, but also in long-term abdominal discomfort. In this article, we presented a case with adnexal torsion that rarely cause acute abdominal pain in postmenopausal women. [Cukurova Med J 2016; 41(1.000: 167-170

  2. Tensile mechanical behavior of hollow and filled carbon nanotubes under tension or combined tension-torsion

    Science.gov (United States)

    Jeong, Byeong-Woo; Lim, Jang-Keun; Sinnott, Susan B.

    2007-01-01

    The tensile mechanical behavior of hollow and filled single-walled carbon nanotubes under tension or combined tension-torsion is examined using classical molecular dynamics simulations. These simulations indicate that the tensile strength under combined tension-torsion can be increased by filling the carbon nanotubes, and the amount of this increase depends on the kind of filling material. They also predict that the tensile strength under combined tension-torsion decreases linearly under applied torsion. The tensile strength can be modified by adjusting the system temperature and through chemical functionalization to the carbon nanotube walls.

  3. Cyclic Sieving for torsion pairs in the cluster category of Dynkin type A_n

    OpenAIRE

    Kluge, Stefan; Rubey, Martin

    2011-01-01

    Recently, a combinatorial model for torsion pairs in the cluster category of Dynkin type A_n was introduced, and used to derive an explicit formula for their number. In this article we determine the number of torsion pairs that are invariant under b-fold application of Auslander-Reiten translation. It turns out that the set of torsion pairs together with Auslander-Reiten translation, and a natural q-analogue of the formula for the number of all torsion pairs exhibits the cyclic sieving phenom...

  4. Torsion of a mucocele of the vermiform appendix: a case report and review of the literature.

    Science.gov (United States)

    Lee, Chang Ho; Lee, Min Ro; Kim, Jae-Chun; Kang, Myoung Jae; Jeong, Yeon Jun

    2011-12-01

    Torsion of a mucocele of the vermiform appendix is an extremely rare condition and also a rare cause of an acute abdomen with a clinical presentation that is indistinguishable from acute appendicitis, and thus, the condition is diagnosed during operation. Here, the authors describe the case of a 78-year-old female, who presented with intermittent abdominal pain. The appendix had a pelvic position and the torsion was counterclockwise. In addition, the torsion was associated with mucocele of the appendix, which was considered a secondary factor of torsion. Appendectomy and drainage were performed.

  5. Bending and torsional stiffness in cadaver humeri fixed with a self-locking expandable or interlocking nail system: a mechanical study.

    Science.gov (United States)

    Blum, Jochen; Karagül, Göksen; Sternstein, Werner; Rommens, Pol M

    2005-09-01

    This study was designed to gain data about a new expandable, noninterlocked intramedullary nail's capacity to stabilize unstable transverse humeral shaft fractures without the need for interlocking, thus making nail implantation simpler and to prove our goal hypothesis: that in a midshaft osteotomy of the humeral shaft the expandable humeral nail will show the same bending and torsional stiffness as an interlocked humeral nail, when implanted correctly according to the manufacturer's instructions. Pair randomization. Mechanical laboratory testing. Eight pairs of freshly harvested cadaveric humeri. Fracture model was a midshaft transverse osteotomy, gapped to 3 mm. Each humerus pair received an expandable humeral nail (Fixion) or an interlocked humerus nail (Synthes) through a retrograde approach. The humeri were fixed in polymethylmethacrylate cylinders and tested in a servo-pneumatic material-testing machine. Torsional stiffness and bending stiffness of the nail-bone-construction. Expandable nails (interlocked nails) showed a lateral bending stiffness of 0.73 +/- 0.14 (0.63 +/- 0.1) KN/mm (P = 0.026) and a frontal bending stiffness of 0.67 +/- 0.18 (0.58 +/- 0.09) KN/mm (P = 0.084). Torsional stiffness values were 0.13 +/- 0.19 (0.43 +/- 0.09 Nm/degrees) (P = 0.012). Lower torsional stiffness in the expandable nail group was observed in humeri with a funnel shaped proximal intramedullary canal. The nail systems showed similar characteristics for frontal bending (P = 0.084), but not for lateral bending (P = 0.026). For lateral bending, the Fixion nail showed significantly more stiffness than the UHN nail (P = 0.026). There was significantly lower torsional stiffness with expandable nails compared with interlocked nails. Clinical correlation would suggest that in rotationally unstable fractures (A2 and A3 diaphyseal fractures), interlocked nails would provide increased stability over expandable nails.

  6. Anterior cruciate ligament injury induced by internal tibial torsion or tibiofemoral compression.

    Science.gov (United States)

    Meyer, Eric G; Haut, Roger C

    2008-12-05

    The knee is one of the most frequently injured joints in the human body. Approximately 91% of ACL injuries occur during sporting activities, usually from a non-contact event. The most common kinetic scenarios related with ACL injuries are internal twisting of the tibia relative to the femur or combined torque and compression during a hard landing. The hypothesis of this study was that the magnitudes and types of motion observed after ACL rupture would significantly change from the relative joint displacements present just before ACL injury. Compression or torsion experiments were conducted on 7 pairs of knee joints with repetitive tests at increasing intensity until catastrophic failure. ACL injury was documented in all cases at 5.4+/-2kN of TF compression or 33+/-13Nm of internal tibial torque. The femur displaced posteriorly relative to the tibia in pre-failure and with a higher magnitude in failure tests under both loading conditions. In compression experiments there was internal rotation of the tibia in pre-failure tests, but external rotation of the tibia after the ACL failed. In torsion experiments, failure occurred at 58+/-19 degrees of internal tibial rotation, and valgus rotation of the femur increased significantly after ACL injury. These new data show that the joint motions can vary in magnitude and direction before and after failure of the ACL. Video-based studies consistently document external rotation of the tibia combined with valgus knee bending as the mechanism of ACL injury although these motions could be occurring after ACL rupture.

  7. [The functional sport shoe parameter "torsion" within running shoe research--a literature review].

    Science.gov (United States)

    Michel, F I; Kälin, X; Metzger, A; Westphal, K; Schweizer, F; Campe, S; Segesser, B

    2009-12-01

    Within the sport shoe area torsion is described as the twisting and decoupling of the rear-, mid- and forefoot along the longitudinal axis of the foot. Studies have shown that running shoes restrict the torsion of the foot and thus they increase the pronation of the foot. Based on the findings, it is recommended to design running shoes, which allow the natural freedom of movement of the foot. The market introduction of the first torsion concept through adidas(R) took place in 1989. Independently of the first market introduction, only one epidemiological study was conducted in the running shoe area. The study should investigate the occurrence of Achilles tendon problems of the athletes running in the new "adidas Torsion(R) shoes". However, further studies quantifying the optimal region of torsionability concerning the reduction of injury incidence are still missing. Newer studies reveal that the criterion torsion only plays a secondary roll regarding the buying decision. Moreover, athletes are not able to perceive torsionability as a discrete functional parameter. It is to register, that several workgroups are dealing intensively with the detailed analysis of the foot movement based on kinematic multi-segment-models. However, scientific as well as popular scientific contributions display that the original idea of the torsion concept is still not completely understood. Hence, the "inverse" characteristic is postulated. The present literature review leads to the deduction that the functional characteristics of the torsion concept are not fully implemented within the running shoe area. This implies the necessity of scientific studies, which investigate the relevance of a functional torsion concept regarding injury prevention based on basic and applied research. Besides, biomechanical studies should analyse systematically the mechanism and the effects of torsion relevant technologies and systems.

  8. The evolution of space curves by curvature and torsion

    International Nuclear Information System (INIS)

    Richardson, G; King, J R

    2002-01-01

    We apply Lie group based similarity methods to the study of a new, and widely relevant, class of objects, namely motions of a space curve. In particular, we consider the motion of a curve evolving with a curvature κ and torsion τ dependent velocity law. We systematically derive the Lie point symmetries of all such laws of motion and use these to catalogue all their possible similarity reductions. This calculation reveals special classes of law with high degrees of symmetry (and a correspondingly large number of similarity reductions). Of particular note is one class which is invariant under general linear transformations in space. This has potential applications in pattern and signal recognition

  9. Elastic limit and strain hardening of thin wires in torsion.

    Science.gov (United States)

    Dunstan, D J; Ehrler, B; Bossis, R; Joly, S; P'ng, K M Y; Bushby, A J

    2009-10-09

    A theory for the size effect in the strength of wires under torsion is reported and compared with data from thin copper wires. Critical thickness theory is solved rigorously and used to validate a useful approximation which is combined with slip-distance theory modified for a finite structure size. Experimental data with high accuracy around and above the elastic limit show excellent agreement with the theory. The results strongly imply that the physical principle is the constraint that size, whether grain size or structure size, puts on allowed dislocation curvature.

  10. Dislocations and torsion in graphene and related systems

    International Nuclear Information System (INIS)

    Juan, Fernando de; Cortijo, Alberto; Vozmediano, Maria A.H.

    2010-01-01

    A continuum model to study the influence of dislocations on the electronic properties of condensed matter systems is described and analyzed. The model is based on a geometrical formalism that associates a density of dislocations with the torsion tensor and uses the technique of quantum field theory in curved space. When applied to two-dimensional systems with Dirac points like graphene we find that dislocations couple in the form of vector gauge fields similar to these arising from curvature or elastic strain. We also describe the ways to couple dislocations to normal metals with a Fermi surface.

  11. Isotropic Stars in Higher-Order Torsion Scalar Theories

    Directory of Open Access Journals (Sweden)

    Gamal G. L. Nashed

    2016-01-01

    Full Text Available Two different nondiagonal tetrad spaces reproducing spherically symmetric spacetime are applied to the field equations of higher-order torsion scalar theories. Assuming the existence of conformal Killing vector, two isotropic solutions are derived. We show that the first solution is not stable while the second one confirms a stable behavior. We also discuss the construction of the stellar model and show that one of our solutions is capable of such construction while the other is not. Finally, we discuss the generalized Tolman-Oppenheimer-Volkoff and show that one of our models has a tendency to equilibrium.

  12. Probabilistic-graphical and phenomenological analysis of combined bending-torsion fatigue reliability data

    Science.gov (United States)

    Kececioglu, D.; Broome, H.

    1969-01-01

    Fatigue data generated by three combined bending-torsion fatigue reliability research machines at The University of Arizona are probabilistic-graphically and phenomenologically analyzed. Distributions that are applicable to fatique life and static strength data are discussed. Phenomenological justifications for the use of these distributions are presented. It is found that the normal distribution represents the cycles-to-failure data at the highest stress levels best. The lognormal distribution appears to fit the cycles-to-failure data at the lower stress levels best and quite well at all stress levels including the highest. A regression analysis and least-squares goodness-of-fit test was performed for normal and lognormal plots. In most cases, the correlation coefficient gave a better fit to the data using the normal distribution, but the difference between the two was so slight that positive discrimination could not be made.

  13. NASA/University JOint VEnture (JOVE) Program: Transverse Shear Moduli Using the Torsional Responses of Rectangular Laminates

    Science.gov (United States)

    Bogan, Sam

    2001-01-01

    The first year included a study of the non-visible damage of composite overwrapped pressure vessels with B. Poe of the Materials Branch of Nasa-Langley. Early determinations showed a clear reduction in non-visible damage for thin COPVs when partially pressurized rather than unpressurized. Literature searches on Thicker-wall COPVs revealed surface damage but clearly visible. Analysis of current Analytic modeling indicated that that current COPV models lacked sufficient thickness corrections to predict impact damage. After a comprehensive study of available published data and numerous numerical studies based on observed data from Langley, the analytic framework for modeling the behavior was determined lacking and both Poe and Bogan suggested any short term (3yr) result for Jove would be overly ambitious and emphasis should be placed on transverse shear moduli studies. Transverse shear moduli determination is relevant to the study of fatigue, fracture and aging effects in composite structures. Based on the techniques developed by Daniel & Tsai, Bogan and Gates determined to verify the results for K3B and 8320. A detailed analytic and experimental plan was established and carried out that included variations in layup, width, thickness, and length. As well as loading rate variations to determine effects and relaxation moduli. The additional axial loads during the torsion testing were studied as was the placement of gages along the composite specimen. Of the proposed tasks, all of tasks I and 2 were completed with presentations given at Langley, SEM conferences and ASME/AIAA conferences. Sensitivity issues with the technique associated with the use of servohydraulic test systems for applying the torsional load to the composite specimen limited the torsion range for predictable and repeatable transverse shear properties. Bogan and Gates determined to diverge on research efforts with Gates continuing the experimental testing at Langley and Bogan modeling the apparent non

  14. Angular position of the cleat according to torsional parameters of the cyclist's lower limb.

    Science.gov (United States)

    Ramos-Ortega, Javier; Domínguez, Gabriel; Castillo, José Manuel; Fernández-Seguín, Lourdes; Munuera, Pedro V

    2014-05-01

    The aim of this work was to study the relationship of torsional and rotational parameters of the lower limb with a specific angular position of the cleat to establish whether these variables affect the adjustment of the cleat. Correlational study. Motion analysis laboratory. Thirty-seven male cyclists of high performance. The variables studied of the cyclist's lower limb were hip rotation (internal and external), tibial torsion angle, Q angle, and forefoot adductus angle. The cleat angle was measured through a photograph of the sole and with an Rx of this using the software AutoCAD 2008. The variables were photograph angle (photograph), the variable denominated cleat-tarsus minor angle, and a variable denominated cleat-second metatarsal angle (Rx). Analysis included the intraclass correlation coefficient for the reliability of the measurements, Student's t test performed on the dependent variables to compare side, and the multiple linear regression models were calculated using the software SPSS 15.0 for Windows. The Student's t test performed on the dependent variables to compare side showed no significant differences (P = 0.209 for the photograph angle, P = 0.735 for the cleat-tarsus minor angle, and P = 0.801 for the cleat-second metatarsal angle). Values of R and R2 for the photograph angle model were 0.303 and 0.092 (P = 0.08), the cleat/tarsus minor angle model were 0.683 and 0.466 (P cleat/second metatarsal angle model were 0.618 and 0.382, respectively (P cleat-tarsus minor angle = 75.094 - (0.521 × forefoot adductus angle) + (0.116 × outward rotation of the hips) + (0.220 × Q angle).

  15. Effect of cyclic torsional preloading on cyclic fatigue resistance of ProTaper Next and Mtwo nickel–titanium instruments

    Directory of Open Access Journals (Sweden)

    Eugenio Pedullà

    2015-06-01

    Conclusions: Torsional preloads reduced the cyclic fatigue resistance of M-wire and conventional (as ProTaper Next and Mtwo NiTi rotary instruments except for Mtwo with 25% or 50% of torsional preloading.

  16. Should Torsion Balance Technique Continue to be Taught to Pharmacy Students?

    Science.gov (United States)

    Bilger, Rhonda; Chereson, Rasma; Salama, Noha Nabil

    2017-06-01

    Objective. To determine the types of balances used in compounding pharmacies: torsion or digital. Methods. A survey was mailed to the pharmacist-in-charge at 698 pharmacies, representing 47% of the pharmacies in Missouri as of July 2013. The pharmacies were randomly selected and stratified by region into eight regions to ensure a representative sample. Information was gathered regarding the type and use of balances and pharmacists' perspectives on the need to teach torsion balance technique to pharmacy students. Results. The response rate for the survey was 53.3%. Out of the total responses received, those pharmacies having a torsion balance, digital balance or both were 46.8%, 27.4% and 11.8%, respectively. About 68.3% of respondents compound prescriptions. The study showed that 52% of compounding pharmacies use torsion balances in their practice. Of those with a balance in their pharmacy, 65.6% favored continuation of torsion balance instruction. Conclusions. Digital balances have become increasingly popular and have replaced torsion balances in some pharmacies, especially those that compound a significant number of prescriptions. The results of this study indicate that torsion balances remain integral to compounding practice. Therefore, students should continue being taught torsion balance technique at the college.

  17. Nonspecificity of the rim sign in the scintigraphic diagnosis of missed testicular torsion

    Energy Technology Data Exchange (ETDEWEB)

    Vieras, F.; Kuhn, C.R.

    1983-02-01

    Causes of a hyperemic peritesticular rim on dynamic and static scintigrams are reviewed. Of 6 patients exhibiting such a pattern, 3 had missed testicular torsion; the other 3 had tumor, trauma, or inflamation. The authors conclude that a hyperemic peritesticular rim is a nonspecific finding reflecting underlying pathophysiological changes and is not pathognomonic of missed torsion.

  18. Torsion of the fallopian the mimicking appendicitis in a pregnant woman

    International Nuclear Information System (INIS)

    Tapia-Vine, M.; Pedrosa, I.; Escribano, N.

    2000-01-01

    Isolated torsion of the fallopian tube is an uncommon entity. Given the difficulties involved in the preoperative diagnosis, the ultrasound findings characteristic of this anomaly are not widely known. We present a case of tubal torsion associated with a cyst, describing the ultrasound images in our case and those reported in the literature. (Author) 18 refs

  19. Uterine Torsion in a West African Dwarf Ewe in Ibadan, Nigeria ...

    African Journals Online (AJOL)

    Keywords: Uterine torsion, West African Dwarf Ewe, Ibadan A case of uterine torsion in a 21/2 year old pluriparous West Africa Dwarf (WAD) ewe raised semi intensively with adequate veterinary care before the death of the dam and the lamb is presented. The dam had been off feed for 3 days and was found straining a night ...

  20. Torsion zero-cycles and the Abel-Jacobi map over the real numbers

    NARCIS (Netherlands)

    Hamel, J. van

    1999-01-01

    This is a study of the torsion in the Chow group of zero-cycles on a variety over the real numbers. The first section recalls important results from the literature. The rest of the paper is devoted to the study of the Abel–Jacobi map a: A0XAlbXR restricted to torsion subgroups. Using Roitman’s

  1. Contribution of the otoliths to the human torsional vestibulo-ocular reflex

    NARCIS (Netherlands)

    Groen, Eric; Bos, Jelte E.; De Graaf, Bernd

    1999-01-01

    The dynamic contribution of the otolith organs to the human ocular torsion response was examined during passive sinusoidal body roll about an earth-horizontal axis (varying otolith inputs) and about an earth-vertical axis (invariant otolith inputs). Torsional eye movements were registered in 5

  2. Analysis of torsional barrier height of HSNO as the simplest S ...

    Indian Academy of Sciences (India)

    and relative energies of HSNO isomers have been reported.7,8 To the best of our knowledge, no compa- rative computational studies about torsional potential of thionitrous acid have been carried out. In this study, we perform a series of ab initio calculations in order to compute the torsional barrier height of HSNO and also.

  3. Intermittent torsion of accessory hepatic lobe: An unusual cause of recurrent right upper quadrant pain

    Directory of Open Access Journals (Sweden)

    Jambhekar Kedar

    2010-01-01

    Full Text Available An accessory lobe of the liver is a rare congenital anomaly that can undergo torsion and present as an acute surgical emergency. It is rarely diagnosed preoperatively. We report the preoperative utility of CT scan and MRI in the diagnosis and surgical planning of a case of intermittent accessory hepatic lobe torsion.

  4. Unsteady flow due to a disk executing non-torsional oscillation and ...

    Indian Academy of Sciences (India)

    This paper is concerned with the unsteady flow of a disk performing non-torsional oscillation in its own plane and a Newtonian fluid at infinity while they are initially rotating with the same angular velocity about non-coaxial axes. For a more general study, it is considered that the disk executes non-torsional oscillation along ...

  5. Management of Testicular torsion in Mulago Hospital over a 5-year ...

    African Journals Online (AJOL)

    A retrospective study of patients seen in Mulago Hospital with a clinical diagnosis of testicular torsion between 1993 and 1997 inclusive was undertaken. There were a total of 102 cases of torsion of the testis. Their ages ranged between 16 and 20 years. Over 50% of the patients reported to the hospital more than 48 hours ...

  6. Management of Testicular torsion in Mulago Hospital over a 5-year ...

    African Journals Online (AJOL)

    Management of Testicular torsion in Mulago Hospital over a 5-year period. Ibingira C B R. hI hled (Surg). 1-ecturer in Anatom!; Makerere University hfedical School. P O Box 7072, Itorsion, and management. A retrospective study of patients seen in. Mulago Hospital with a ...

  7. Torsional Ultrasound Sensor Optimization for Soft Tissue Characterization

    Directory of Open Access Journals (Sweden)

    Juan Melchor

    2017-06-01

    Full Text Available Torsion mechanical waves have the capability to characterize shear stiffness moduli of soft tissue. Under this hypothesis, a computational methodology is proposed to design and optimize a piezoelectrics-based transmitter and receiver to generate and measure the response of torsional ultrasonic waves. The procedure employed is divided into two steps: (i a finite element method (FEM is developed to obtain a transmitted and received waveform as well as a resonance frequency of a previous geometry validated with a semi-analytical simplified model and (ii a probabilistic optimality criteria of the design based on inverse problem from the estimation of robust probability of detection (RPOD to maximize the detection of the pathology defined in terms of changes of shear stiffness. This study collects different options of design in two separated models, in transmission and contact, respectively. The main contribution of this work describes a framework to establish such as forward, inverse and optimization procedures to choose a set of appropriate parameters of a transducer. This methodological framework may be generalizable for other different applications.

  8. Giant Meckel’s diverticulum torsion that mimics adnexal pathology

    Directory of Open Access Journals (Sweden)

    Serdar Kirmizi

    2016-01-01

    Full Text Available Meckel’s diverticulum is a real diverticulum located at the antimesenteric portion of intestinal loops and including all layers of the intestinal wall. It is the most common congenital anomaly of the gastrointestinal tract, and its incidence is 1–3%. Many asymptomatic cases are diagnosed when complications occur. A 23-year-old female patient applied to gynaecology emergency clinic with pelvic pain complaint. Laparotomy was performed with the diagnosis of acute abdomen because the physical examination and imaging studies did not exclude tuboovary pathology. Giant Meckel’s diverticulitis and ischemic bowel loops that had been torsion were observed. Obstruction is the most common complication and generally originates from inflammation, adhesions, intussusception and omphalo-mesenteric band. In this case, it was seen that mobilized diverticulitis can be complicated without any fibrous band or adhesion to adjacent organs. This case supports that there can be torsion of bowel in free Meckel’s diverticulum. Meckel’s diverticulum settled in the pelvic region can make a clinical manifestation that is difficult to distinguish from adnexal diseases. It should be kept in mind for cases that start with pelvic pain, form adnexal pathology suspicion and cause an acute abdomen.

  9. Acute abdomen due to primary omental torsion: case report.

    Science.gov (United States)

    Tsironis, Apostolos; Zikos, Nikolaos; Bali, Christina; Pappas-Gogos, George; Koulas, Spiridon; Katsamakis, Nikolaos

    2013-01-01

    Primary torsion of the greater omentum is an uncommon cause of acute abdominal pain that mainly affects adults in their fourth or fifth decade. It was first described by Eitel in 1899. Since then, more than 300 cases have been reported in the published literature. Clinical presentation and imaging findings are often of limited value in the diagnosis of primary omental torsion (POT). The patients usually undergo laparotomy for "acute appendicitis" or acute abdomen of poorly defined origin. To provide a detailed description of this rare cause of acute abdomen. We report a case of POT in a woman of reproductive age and discuss contemporary methods in diagnosis and management of the condition. Nowadays, laparoscopy is a safe and effective approach for the diagnosis and management of POT, with the advantages of reduced postoperative pain and hospital stay. Conservative management has also been advocated by some authors in selected patients with a preoperative diagnosis of POT based on computed tomography findings. Copyright © 2013 Elsevier Inc. All rights reserved.

  10. Cosmology with torsion: An alternative to cosmic inflation

    International Nuclear Information System (INIS)

    Poplawski, Nikodem J.

    2010-01-01

    We propose a simple scenario which explains why our Universe appears spatially flat, homogeneous and isotropic. We use the Einstein-Cartan-Kibble-Sciama (ECKS) theory of gravity which naturally extends general relativity to include the spin of matter. The torsion of spacetime generates gravitational repulsion in the early Universe filled with quarks and leptons, preventing the cosmological singularity: the Universe expands from a state of minimum but finite radius. We show that the dynamics of the closed Universe immediately after this state naturally solves the flatness and horizon problems in cosmology because of an extremely small and negative torsion density parameter, Ω S ∼-10 -69 . Thus the ECKS gravity provides a compelling alternative to speculative mechanisms of standard cosmic inflation. This scenario also suggests that the contraction of our Universe preceding the bounce at the minimum radius may correspond to the dynamics of matter inside a collapsing black hole existing in another universe, which could explain the origin of the Big Bang.

  11. Acute gallbladder torsion - a continued pre-operative diagnostic dilemma

    Directory of Open Access Journals (Sweden)

    Desrochers Randal

    2011-04-01

    Full Text Available Abstract Acute gallbladder volvulus continues to remain a relatively uncommon process, manifesting itself usually during exploration for an acute surgical abdomen with a presumptive diagnosis of acute cholecystitis. The pathophysiology is that of mechanical organo-axial torsion along the gallbladder's longitudinal axis involving the cystic duct and cystic artery, and with a pre-requisite of local mesenteric redundancy. The demographic tendency is septua- and octo-genarians of the female sex, and its overall incidence is increasing, this being attributed to increasing life expectancy. We discuss two cases of elderly, fragile women presenting to the emergency department complaining of sudden onset right upper quadrant abdominal pain. Their subsequent evaluation suggested acute cholecystitis. Ultimately both were taken to the operating room where the correct diagnosis of gallbladder torsion was made. Pre-operative diagnosis continues to be a major challenge with only 4 cases reported in the literature diagnosed with pre-operative imaging; the remainder were found intra-operatively. Consequently, a delay in diagnosis can have devastating patient outcomes. Herein we propose a necessary high index of suspicion for gallbladder volvulus in the outlined patient demographic with symptoms and signs mimicking acute cholecystitis.

  12. The physics of detecting torsion and placing limits on its effects

    International Nuclear Information System (INIS)

    Stoeger, W.R.

    1985-01-01

    The essential principles of torsion-detection physics are presented and several conceivable types of experiments and observations for actually detecting torsion fields are evaluated reemphasizing also the evident impossibility of successfully searching for its manifestations among cosmological relics. In particular, a polarized body, with net intrinsic (fundamental-particle) spin, is essential for detecting a torsion field. One which possesses only orbital angular momentum-rotation-or an unpolarized intrinsic spin density will not feel torsion. The fundamental problem in searching for such fields is the extremely small basic unit of the coupling or interaction energy between the torsion field and spin, epsilonapprox.(8πG'/c 2 )(h 2 /4). The best way of maximizing the total interaction energy is to increase the spin density of the source σ 5 and, at the same time the ''spin number'' Ssub(D) of the detector. (author)

  13. Exact interior solutions for static spheres in the Einstein-Cartan theory with two sources of torsion

    CERN Document Server

    Gallakhmetov, A M

    2002-01-01

    In the framework of the problem of existence of exact interior solutions for static spherically symmetric configurations in the Einstein-Cartan theory (ECT), the distributions of perfect fluid and non-minimally coupled scalar field are considered. The exact solutions in the one-torsion ECT and two-torsion one are obtained. Some consequences of two sources of torsion are discussed.

  14. Rat disc torsional mechanics: effect of lumbar and caudal levels and axial compression load.

    Science.gov (United States)

    Espinoza Orías, Alejandro A; Malhotra, Neil R; Elliott, Dawn M

    2009-03-01

    Rat models with altered loading are used to study disc degeneration and mechano-transduction. Given the prominent role of mechanics in disc function and degeneration, it is critical to measure mechanical behavior to evaluate changes after model interventions. Axial compression mechanics of the rat disc are representative of the human disc when normalized by geometry, and differences between the lumbar and caudal disc have been quantified in axial compression. No study has quantified rat disc torsional mechanics. Compare the torsional mechanical behavior of rat lumbar and caudal discs, determine the contribution of combined axial load on torsional mechanics, and compare the torsional properties of rat discs to human lumbar discs. Cadaveric biomechanical study. Cyclic torsion without compressive load followed by cyclic torsion with a fixed compressive load was applied to rat lumbar and caudal disc levels. The apparent torsional modulus was higher in the lumbar region than in the caudal region: 0.081+/-0.026 (MPa/degrees, mean+/-SD) for lumbar axially loaded; 0.066+/-0.028 for caudal axially loaded; 0.091+/-0.033 for lumbar in pure torsion; and 0.056+/-0.035 for caudal in pure torsion. These values were similar to human disc properties reported in the literature ranging from 0.024 to 0.21 MPa/degrees. Use of the caudal disc as a model may be appropriate if the mechanical focus is within the linear region of the loading regime. These results provide support for use of this animal model in basic science studies with respect to torsional mechanics.

  15. Inhomogeneous microstructural evolution of pure iron during high-pressure torsion

    International Nuclear Information System (INIS)

    Descartes, S.; Desrayaud, C.; Rauch, E.F.

    2011-01-01

    Research highlights: → Three techniques (FIB, EBSD, and ACOM-TEM) are used to characterize highly deformed high purity iron grade. → Fine microstructure is obtained at low pressure (0.5 GPa), after 1 rev. with the unconstrained HPT. → Fine microstructure generation is correlated with contact conditions. → Microstructural evolution mechanism is assimilated to continuous dynamic recrystallisation. → Significant continuous misorientation gradient in the grains is highlighted. - Abstract: A Bridgman anvil apparatus (unconstrained high-pressure torsion configuration) was used to shear samples of ultra high purity iron (99.99999%) in torsion under pressure (0.5 GPa). The evolution of the resulting microstructure was characterized by focused ion beam imaging (FIB), electron backscattered diffraction mapping (EBSD) and automated crystal orientation mapping in a transmission electron microscope (ACOM-TEM). The initial large grains (100 μm) were fragmented first; with the resulting deformation causing low angle dislocation boundaries followed by a gradual increase in their misorientation, finally leading to the formation of fine structural or microstructural elements (substructure) with high misorientations. These final structural elements (about 220 nm) could be considered as grains, if viewed from the conventional terms to describe grain (as that being entirely delimited by continuous HAB). One possible mechanism of formation could be continuous dynamic recrystallization. Furthermore deformation caused by the tests led to continuous misorientation in the grains whereas a significant continuous misorientation gradient in the grains was highlighted. The formation of predominant sub-micronic crystalline structure resulted in a significant increase in strength while good ductility was maintained. At a microscopic scale there was evidence that the refinement first occurred in the near surface layer of the sample and then propagated through the whole volume with a

  16. Lorentz violation bounds from torsion trace fermion sector and galaxy M51 data and chiral dynamos

    Energy Technology Data Exchange (ETDEWEB)

    Garcia de Andrade, L.C. [IF-UERJ, Departamento de Fisica Teorica, Rio de Janeiro, RJ (Brazil)

    2017-06-15

    Earlier we have computed a Lorentz violation (LV) bound for torsion terms via galactic dynamos and found bounds similar to the one obtained by Kostelecky et al. (Phys Rev Lett 100:111102, 2008) which is of the order of 10{sup -31} GeV. Their result was found making use of the axial torsion vector in terms of Dirac spinors and minimal torsion coupling in flat space-time of fermions. In this paper, a torsion dynamo equation obtained using the variation of the torsion trace and galaxy M51 data of 500 pc are used to place an upper bound of 10{sup -26} GeV in LV, which agrees with the one by Kostelecky and his group using an astrophysical framework background. Their lowest bound was obtained in earth laboratory using dual masers. One of the purposes of this paper is to apply the Faraday self-induction magnetic equation, recently extended to torsioned space-time, by the author to show that it lends support to physics in Riemann-Cartan space-time, in several distinct physical backgrounds. Backreaction magnetic effects are used to obtain the LV bounds. Previously Bamba et al. (JCAP 10:058, 2012) have used the torsion trace in their teleparallel investigation of the IGMF, with the argument that the torsion trace leads to less weaker effects than the other irreducible components of the torsion tensor. LV is computed in terms of a chiral-torsion-like current in the new dynamo equation analogous to the Dvornikov and Semikoz dynamo equation with chiral magnetic currents. Making use of the chiral-torsion dynamo equation we estimate the LV bounds in the early universe to be of the order of 10{sup -24} GeV, which was the order of the charged-lepton sector. Our main result is that it is possible to obtain more stringent bounds than the ones found in the fermion sector of astrophysics in the new revised 2017 data table for CPT and Lorentz violation by Kostelecky and Mewes. They found in several astrophysical backgrounds, orders of magnitude such as 10{sup -24} and 10{sup -23} Ge

  17. Lorentz violation bounds from torsion trace fermion sector and galaxy M 51 data and chiral dynamos

    Science.gov (United States)

    Garcia de Andrade, L. C.

    2017-06-01

    Earlier we have computed a Lorentz violation (LV) bound for torsion terms via galactic dynamos and found bounds similar to the one obtained by Kostelecky et al. (Phys Rev Lett 100:111102, 2008) which is of the order of 10^{-31} GeV. Their result was found making use of the axial torsion vector in terms of Dirac spinors and minimal torsion coupling in flat space-time of fermions. In this paper, a torsion dynamo equation obtained using the variation of the torsion trace and galaxy M51 data of 500 pc are used to place an upper bound of 10^{-26} GeV in LV, which agrees with the one by Kostelecky and his group using an astrophysical framework background. Their lowest bound was obtained in earth laboratory using dual masers. One of the purposes of this paper is to apply the Faraday self-induction magnetic equation, recently extended to torsioned space-time, by the author to show that it lends support to physics in Riemann-Cartan space-time, in several distinct physical backgrounds. Backreaction magnetic effects are used to obtain the LV bounds. Previously Bamba et al. (JCAP 10:058, 2012) have used the torsion trace in their teleparallel investigation of the IGMF, with the argument that the torsion trace leads to less weaker effects than the other irreducible components of the torsion tensor. LV is computed in terms of a chiral-torsion-like current in the new dynamo equation analogous to the Dvornikov and Semikoz dynamo equation with chiral magnetic currents. Making use of the chiral-torsion dynamo equation we estimate the LV bounds in the early universe to be of the order of 10^{-24} GeV, which was the order of the charged-lepton sector. Our main result is that it is possible to obtain more stringent bounds than the ones found in the fermion sector of astrophysics in the new revised 2017 data table for CPT and Lorentz violation by Kostelecky and Mewes. They found in several astrophysical backgrounds, orders of magnitude such as 10^{-24} and 10^{-23} GeV which are not so

  18. Experimental development of a torsion arc blade type horizontal axis windmil; Nejire enko yokugata suihei jiku fusha no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Kojima, N. [Meiji Univ., Tokyo (Japan). Faculty of Scince and Technology

    1996-05-31

    To get more wind energy, longer rotating blades and higher towers of windmills are required. Therefore, the location of windmills is limited and the initial cost gets higher. In this study, a small size windmill which can generate electricity even in a city was developed and tested. A torsion arc blade type horizontal axis windmill was designed and the blade form, number and degree of distortion were investigated. Based on the results, a small windmill was made, rotation and generation tests were carried out and it was confirmed that the windmill could be used as a small scale wind power generation. The windmill is of simple construction having 6 arc blades and no high tower is required. This paper consists of 6 sections, i.e. Introduction, Windmill model, Tested windmill, Test facility and method, Test results and consideration, and Postscript. 2 refs., 18 figs., 1 tab.

  19. Study on Forced Torsional Vibration of CFRP Drive-Line System with Internal Damping

    Science.gov (United States)

    Yang, Mo; Hu, Yefa; Zhang, Jinguang; Ding, Guoping; Song, Chunsheng

    2017-12-01

    The use of CFRP transmission shaft has positive effect on the weight and flexural vibration reduction of drive-line system. However, the application of CFRP transmission shaft will greatly reduce the torsional stiffness of the drive-line, and may cause strong transient torsional vibration. Which will seriously affect the performance of CFRP drive-line. In this study, the forced torsional vibration of the CFRP drive-line system is carried out using the lumped parameter model. In addition, the effect of rotary inertia, internal damping, coupling due to the composite laminate, and excitation torque are incorporated in the modified transfer matrix model (TMM). Then, the modified TMM is used to predict the torsional frequency and forced torsional vibration of a CFRP drive-line with three-segment drive shafts. The results of modified TMM shown that the rotational speed difference of the CFRP transmission shaft segment is much larger than metal transmission shaft segment under excitation torque. And compared the results from finite element simulation, modified TMM and torsional vibration experiment respectively, and it has shown that the modified TMM can accurately predict forced torsional vibration behaviors of the CFRP drive-line system.

  20. Saint-Venant torsion of non-homogeneous anisotropic bars

    Directory of Open Access Journals (Sweden)

    John T. Katsikadelis

    2016-01-01

    Full Text Available The BEM is applied to the solution of the torsion problem of non-homogeneous anisotropic non-circular prismatic bars. The problem is formulated in terms of the warping function. This formulation leads to a second order partial differential equation with variable coefficients, subjected to a generalized Neumann type boundary condition. The problem is solved using the Analog Equation Method (AEM. According to this method, the governing equation is replaced by a Poisson’s equation subjected to a fictitious source under the same boundary condition. The fictitious load is established using the Boundary Element Method (BEM after expanding it into a finite series of radial basis functions. The method has all the advantages of the pure BEM, since the discretization and integration are limited only on to the boundary. Numerical examples are presented which illustrate the efficiency and accuracy of the method.

  1. Torsion-induced magnetoimpedance in nanocrystalline Fe-based wires

    International Nuclear Information System (INIS)

    Santos, J.D.; Olivera, J.; Alvarez, P.; Sanchez, T.; Perez, M.J.; Sanchez, M.L.; Gorria, P.; Hernando, B.

    2007-01-01

    The magnetic field influence on the real and imaginary parts of axial-diagonal (ζ zz ) and off-diagonal (ζ φz ) components of the surface magnetoimpedance (MI) tensor has been studied in amorphous and nanocrystalline Fe 73.5 Si 13.5 B 9 Cu 1 Nb 3 wires. Twisted and untwisted wires were annealed at a temperature near to that of primary crystallization. The MI response has been measured at 1MHz and 5mA rms drive current in all the samples. Even though the higher values for both components of the MI tensor are achieved for the untwisted annealed wire, the most interesting features are observed in the torsion annealed wire

  2. Discrete Torsion, (Anti) de Sitter D4-Brane and Tunneling

    Science.gov (United States)

    Singh, Abhishek K.; Pandey, P. K.; Singh, Sunita; Kar, Supriya

    2014-06-01

    We obtain quantum geometries on a vacuum created pair of a (DDbar)3-brane, at a Big Bang singularity, by a local two form on a D4-brane. In fact our analysis is provoked by an established phenomenon leading to a pair creation by a gauge field at a black hole horizon by Stephen Hawking in 1975. Importantly, the five dimensional microscopic black holes are described by an effective non-perturbative curvature underlying a discrete torsion in a second order formalism. In the case for a non-propagating torsion, the effective curvature reduces to Riemannian, which in a low energy limit may describe Einstein vacuum in the formalism. In particular, our analysis suggests that a non-trivial space begin with a hot de Sitter brane-Universe underlying a nucleation of a vacuum pair of (DDbar)-instanton at a Big Bang. A pair of instanton nucleats a D-particle which in turn combines with an anti D-particle to describe a D-string and so on. The nucleation of a pair of higher dimensional pair of brane/anti-brane from a lower dimensional pair may be viewed via an expansion of the brane-Universe upon time. It is in conformity with the conjecture of a branes within a brane presumably in presence of the non-zero modes of two form. Interestingly, we perform a thermal analysis underlying various emergent quantum de Sitter vacua on a D4-brane and argue for the plausible tunneling geometries underlying a thermal equilibrium. It is argued that a de Sitter Schwarzschild undergoes quantum tunneling to an AdS-brane Schwarzschild via Nariai and de Sitter topological black hole.

  3. Effects of a fixation target on torsional optokinetic nystagmus.

    Science.gov (United States)

    Suzuki, Y; Shinmei, Y; Nara, H; Ifukube, T

    2000-09-01

    To investigate the effects of an imaginary and a visual target on torsional optokinetic nystagmus (tOKN) and directional symmetry of tOKN. Torsional OKN was induced by a rotating random dot pattern (52 degrees in diameter, constant angular velocity: +/-30 deg/sec to +/-52 deg/sec) with an imaginary or a visual target in 11 eyes of 10 healthy humans by dual-search coil methods. Intorsional OKN and extorsional OKN were symmetrical in their slow-phase gain. The mean slow-phase gain (0. 037/0.041, intorsion/extorsion) of tOKN during fixation on a visual target at the center of the rotating random dot pattern was significantly (P: extorsion) during fixation on an imaginary target at the center of the rotating random dot pattern. The mean tOKN slow-phase beat duration (840 msec/724 msec, intorsion/extorsion) during fixation on the visual target was significantly (P: extorsion) during fixation on the imaginary target. In seven eyes of six subjects, the mean slow-phase gain and beat duration (0.034 and 812 msec) of tOKN during fixation on a visual target 6.5 degrees left or right from the center of the rotating random dot pattern were not significantly different from those (0.037 and 825 msec) with a visual target at the center of the rotating random dot pattern (P: > 0.3). A visual target spot suppresses tOKN by a nonpursuit visual system. Intorsional and extorsional OKNs were symmetrical.

  4. Discrete Torsion, (Anti) de Sitter D4-Brane and Tunneling

    International Nuclear Information System (INIS)

    Singh, Abhishek K.; Pandey, P.K.; Singh, Sunita; Kar, Supriya

    2014-01-01

    We obtain quantum geometries on a vacuum created pair of a (DD ¯ ) 3 -brane, at a Big Bang singularity, by a local two form on a D 4 -brane. In fact our analysis is provoked by an established phenomenon leading to a pair creation by a gauge field at a black hole horizon by Stephen Hawking in 1975. Importantly, the five dimensional microscopic black holes are described by an effective non-perturbative curvature underlying a discrete torsion in a second order formalism. In the case for a non-propagating torsion, the effective curvature reduces to Riemannian, which in a low energy limit may describe Einstein vacuum in the formalism. In particular, our analysis suggests that a non-trivial space begin with a hot de Sitter brane-Universe underlying a nucleation of a vacuum pair of (DD ¯ )-instanton at a Big Bang. A pair of instanton nucleats a D-particle which in turn combines with an anti D-particle to describe a D-string and so on. The nucleation of a pair of higher dimensional pair of brane/anti-brane from a lower dimensional pair may be viewed via an expansion of the brane-Universe upon time. It is in conformity with the conjecture of a branes within a brane presumably in presence of the non-zero modes of two form. Interestingly, we perform a thermal analysis underlying various emergent quantum de Sitter vacua on a D 4 -brane and argue for the plausible tunneling geometries underlying a thermal equilibrium. It is argued that a de Sitter Schwarzschild undergoes quantum tunneling to an AdS-brane Schwarzschild via Nariai and de Sitter topological black hole

  5. Severe congenital penile torsion with anterior urethral diverticulum: A case report

    Directory of Open Access Journals (Sweden)

    Amilal Bhat

    2018-03-01

    Full Text Available Introduction: We present a rare case of severe penile torsion of 180° along with giant congenital anterior urethral diverticula. Presentation of these two rare anomalies together is extremely rare and has not been reported yet. The extreme rarity of the case and its management warrants this presentation. Observation: A 5 years old boy presented to us as a case of epispadias with post-void dribbling and wetting of the underwears. On examination, he was found to be a case of severe congenital penile torsion with diversion and rotation of median raphae in a counterclockwise fashion upto the midline dorsally confirming 180° torsion. During voiding, there was appearance of a swelling in distal penile region with passage of urinary drops while compressing it. Micturating cystourethrogram showed diverticula in penile and bulbar urethra. Torsion was completely corrected by penile de-gloving in a plane between two layers of buck fascia and mobilization of the urethra along with spongiosum proximally upto the penoscrotal junction and distally upto the glans. Diverticula was laid open and underwent urethroplasty along with double breasting of thickened diverticular tissue. Torsion was completely corrected after surgery. Post-operative recovery was uneventful. Urine culture was sterile and uroflowmetry showed maximal urinary flow of 12 ml/s at 3 months postoperatively. Conclusions: Penile de-gloving and adequate urethral mobilization corrects the severe penile torsion of 180°. Correction of severe torsion and urethroplasty is feasible in a single stage with good results. Keywords: Penile torsion, Urethral diverticula, Congenital anomalies, Mobilization of urethra, Urethroplasty, Double Breasting, Correction of penile torsion

  6. Unusual cause of acute abdomen in a child--torsion of greater omentum: report of two cases.

    Science.gov (United States)

    Pogorelić, Zenon; Katić, Josip; Gudelj, Karla; Mrklić, Ivana; Vilović, Katarina; Perko, Zdravko

    2015-08-01

    Torsion of the omentum is twisting along its long axis and a rare cause of acute abdomen. Depending on associated conditions, it is classified as primary and secondary. It may mimic different pathologies presenting as acute abdomen, most common of them being acute appendicitis. Current choice for management of omental torsion is laparoscopic surgery. We present two cases of omental torsion of two boys who presented with abdominal pain, nausea and vomiting and underwent emergency laparoscopy. Omental torsion is very rare, and its diagnosis is usually made only after surgery. At laparoscopy, omental torsion is suspected when the appendix is normal and the symptoms and findings of torsion are present. Laparoscopy is a safe and effective approach for the diagnosis and management of omental torsion, with the advantages of reduced postoperative pain and hospital stay. © The Author(s) 2015.

  7. Externalised locking compression plate as an alternative to the unilateral external fixator: a biomechanical comparative study of axial and torsional stiffness.

    Science.gov (United States)

    Ang, B F H; Chen, J Y; Yew, A K S; Chua, S K; Chou, S M; Chia, S L; Koh, J S B; Howe, T S

    2017-04-01

    External fixators are the traditional fixation method of choice for contaminated open fractures. However, patient acceptance is low due to the high profile and therefore physical burden of the constructs. An externalised locking compression plate is a low profile alternative. However, the biomechanical differences have not been assessed. The objective of this study was to evaluate the axial and torsional stiffness of the externalised titanium locking compression plate (ET-LCP), the externalised stainless steel locking compression plate (ESS-LCP) and the unilateral external fixator (UEF). A fracture gap model was created to simulate comminuted mid-shaft tibia fractures using synthetic composite bones. Fifteen constructs were stabilised with ET-LCP, ESS-LCP or UEF (five constructs each). The constructs were loaded under both axial and torsional directions to determine construct stiffness. The mean axial stiffness was very similar for UEF (528 N/mm) and ESS-LCP (525 N/mm), while it was slightly lower for ET-LCP (469 N/mm). One-way analysis of variance (ANOVA) testing in all three groups demonstrated no significant difference (F(2,12) = 2.057, p = 0.171).There was a significant difference in mean torsional stiffness between the UEF (0.512 Nm/degree), the ESS-LCP (0.686 Nm/degree) and the ET-LCP (0.639 Nm/degree), as determined by one-way ANOVA (F(2,12) = 6.204, p = 0.014). A Tukey post hoc test revealed that the torsional stiffness of the ESS-LCP was statistically higher than that of the UEF by 0.174 Nm/degree (p = 0.013). No catastrophic failures were observed. Using the LCP as an external fixator may provide a viable and attractive alternative to the traditional UEF as its lower profile makes it more acceptable to patients, while not compromising on axial and torsional stiffness. Cite this article: B. F. H. Ang, J. Y. Chen, A. K. S. Yew, S. K. Chua, S. M. Chou, S. L. Chia, J. S. B. Koh, T. S. Howe. Externalised locking compression plate as an alternative to the

  8. Experiments and FE modeling of stress-strain state in ReBCO tape under tensile, torsional and transverse load

    Science.gov (United States)

    Ilin, K.; Yagotintsev, K. A.; Zhou, C.; Gao, P.; Kosse, J.; Otten, S. J.; Wessel, W. A. J.; Haugan, T. J.; van der Laan, D. C.; Nijhuis, A.

    2015-05-01

    For high current superconductors in high magnet fields with currents in the order of 50 kA, single ReBCO coated conductors must be assembled in a cable. The geometry of such a cable is mostly such that combined torsion, axial and transverse loading states are anticipated in the tapes and tape joints. The resulting strain distribution, caused by different thermal contraction and electromagnetic forces, will affect the critical current of the tapes. Tape performance when subjected to torsion, tensile and transverse loading is the key to understanding limitations for the composite cable performance. The individual tape material components can be deformed, not only elastically but also plastically under these loads. A set of experimental setups, as well as a convenient and accurate method of stress-strain state modeling based on the finite element method have been developed. Systematic measurements on single ReBCO tapes are carried out combining axial tension and torsion as well as transverse loading. Then the behavior of a single tape subjected to the various applied loads is simulated in the model. This paper presents the results of experimental tests and detailed FE modeling of the 3D stress-strain state in a single ReBCO tape under different loads, taking into account the temperature dependence and the elastic-plastic properties of the tape materials, starting from the initial tape processing conditions during its manufacture up to magnet operating conditions. Furthermore a comparison of the simulations with experiments is presented with special attention for the critical force, the threshold where the tape performance becomes irreversibly degraded. We verified the influence of tape surface profile non-uniformity and copper stabilizer thickness on the critical force. The FE models appear to describe the tape experiments adequately and can thus be used as a solid basis for optimization of various cabling concepts.

  9. Existence of Torsional Solitons in a Beam Model of Suspension Bridge

    Science.gov (United States)

    Benci, Vieri; Fortunato, Donato; Gazzola, Filippo

    2017-11-01

    This paper studies the existence of solitons, namely stable solitary waves, in an idealized suspension bridge. The bridge is modeled as an unbounded degenerate plate, that is, a central beam with cross sections, and displays two degrees of freedom: the vertical displacement of the beam and the torsional angles of the cross sections. Under fairly general assumptions, we prove the existence of solitons. Under the additional assumption of large tension in the sustaining cables, we prove that these solitons have a nontrivial torsional component. This appears relevant for security since several suspension bridges collapsed due to torsional oscillations.

  10. Numerical Investigation of Damping of Torsional Beam Vibrations by Viscous Bimoments

    DEFF Research Database (Denmark)

    Hoffmeyer, David; Høgsberg, Jan Becker

    2017-01-01

    Damping of torsional beam vibrations of slender beam–structures with thin–walled cross–sections is investigated. Analytical results from solving the differential equation governing torsion with viscous bimoments imposed at the boundary, are compared with a numerical approach with three......–dimensional, is oparametric elements. The viscous bimoments act on the axial warping displacements associated with in homogeneous torsion, and are in a numerical format realized by suitable configurations of concentrated, axial forces describing discrete dampers.It is illustrated by an example that significant damping ratios...

  11. Generators for the em>l>-torsion subgroup of Jacobians of Genus Two Curves

    DEFF Research Database (Denmark)

    Ravnshøj, Christian Robenhagen

    2008-01-01

    We give an explicit description of the matrix representation of the Frobenius endomorphism on the Jacobian of a genus two curve on the subgroup of l-torsion points. By using this description, we can describe the matrix representation of the Weil-pairing on the subgroup of l-torsion points explici...... explicitly. Finally, the explicit description of the Weil-pairing provides us with an efficient, probabilistic algorithm to find generators of the subgroup of l-torsion points on the Jacobian of a genus two curve....

  12. Effect of torsion angle on electronic transport through different anchoring groups in molecular junction

    International Nuclear Information System (INIS)

    Xia Caijuan; Fang Changfeng; Zhao Peng; Xie Shijie; Liu Desheng

    2009-01-01

    By applying nonequilibrium Green's function formalism combined with first-principles density functional theory, we investigate effect of torsion angle on electronic transport properties of 4,4 ' -biphenyl molecule connected with different anchoring groups (dithiocarboxylate and thiol group) to Au(111) electrodes. The influence of the HOMO-LUMO gaps and the spatial distributions of molecular orbitals on the quantum transport through the molecular device are discussed. Theoretical results show that the torsion angle plays important role in conducting behavior of molecular devices. By changing the torsion angle between two phenyl rings, namely changing the magnitude of the intermolecular coupling effect, a different transport behavior can be observed in these two systems.

  13. Coupled lateral-torsional response of equipment mounted in CANDU nuclear power plants

    International Nuclear Information System (INIS)

    Ishac, M.F.; Heidebrecht, A.C.

    1979-01-01

    In this paper, a coupled lateral torsional model (CLTM) is developed as a modification of the uncoupled lateral torsional model (ULTM) by including the torsional degree of freedom for each mass point and taking into consideration the effect of eccentricities between the centers of mass and rigidity at each floor level. The lateral and rotational time-histories at each floor level are characterized by lateral and rotational floor response spectra at the mass centroid. These time-histories are also combined to determine the lateral floor response spectra at the extreme edges of each floor mass. (orig.)

  14. Extended Reissner-Nordström solutions sourced by dynamical torsion

    Science.gov (United States)

    Cembranos, Jose A. R.; Valcarcel, Jorge Gigante

    2018-04-01

    We find a new exact vacuum solution in the framework of the Poincaré Gauge field theory with massive torsion. In this model, torsion operates as an independent field and introduces corrections to the vacuum structure present in General Relativity. The new static and spherically symmetric configuration shows a Reissner-Nordström-like geometry characterized by a spin charge. It extends the known massless torsion solution to the massive case. The corresponding Reissner-Nordström-de Sitter solution is also compatible with a cosmological constant and additional U (1) gauge fields.

  15. Fiber-Optic Sensors for Measurements of Torsion, Twist and Rotation: A Review †

    Science.gov (United States)

    Budinski, Vedran; Donlagic, Denis

    2017-01-01

    Optical measurement of mechanical parameters is gaining significant commercial interest in different industry sectors. Torsion, twist and rotation are among the very frequently measured mechanical parameters. Recently, twist/torsion/rotation sensors have become a topic of intense fiber-optic sensor research. Various sensing concepts have been reported. Many of those have different properties and performances, and many of them still need to be proven in out-of-the laboratory use. This paper provides an overview of basic approaches and a review of current state-of-the-art in fiber optic sensors for measurements of torsion, twist and/or rotation. PMID:28241510

  16. Acute lower abdominal pain caused by adnexal torsion in a ten-year-old girl

    DEFF Research Database (Denmark)

    Steinthorsdottir, Kristin Julia; Hansen, Lars Folmer; Bisgaard, Thue

    2014-01-01

    A ten-year-old girl presented with four days of lower abdominal pain. A diagnostic laparoscopy on the suspicion of acute appendicitis revealed left-sided adnexal torsion. The cyanotic ovary was detorsed and recovered. At three-month follow-up there were no clinical or ultrasonic signs of pathology....... The clinical presentation of adnexal torsion is unspecific and mimics several differential diagnosis. Adnexal torsion is a rare condition, especially in pre-pubertal girls. However, it must still be kept in mind when evaluating girls regardless of age with lower abdominal pain....

  17. Lagrange multipliers in elastic-plastic torsion problem for nonlinear monotone operators

    Science.gov (United States)

    Giuffrè, S.; Maugeri, A.; Puglisi, D.

    2015-08-01

    The existence of Lagrange multipliers as a Radon measure is ensured for an elastic-plastic torsion problem associated to a nonlinear strictly monotone operator. A regularization of this result, namely the existence of Lp Lagrange multipliers, is obtained under strong monotonicity assumption on the operator. Moreover, the relationships between elastic-plastic torsion problem and the obstacle problem are investigated. Finally, an example of the so-called "Von Mises functions" is provided, namely of solutions of the elastic-plastic torsion problem, associated to nonlinear monotone operators, which are not obtained by means of the obstacle problem in the case f =constant.

  18. Primary torsion of the vermiform appendix and undescended cecum treated by video-assisted transumbilical appendectomy.

    Science.gov (United States)

    Montes-Tapia, Fernando; Quiroga-Garza, Aquiles; Abrego-Moya, Valdemar

    2009-12-01

    Torsion of the vermiform appendix is a rare cause of appendicitis that is clinically indistinguishable from the classical presentation. In this paper, we present the first report in the literature of an appendicular torsion associated with an undescended cecum. A 3-year-old male patient with persistent pain in the right hypochondrium and peritoneal irritation underwent diagnostic laparoscopy, finding necrosis of the vermiform appendix caused by torsion of its base associated with an undescended cecum located in an indurated area of the subhepatic region. A video-assisted transumbilical appendectomy was performed.

  19. A unified approach for determining the ultimate strength of RC members subjected to combined axial force, bending, shear and torsion.

    Science.gov (United States)

    Wang, Pu; Huang, Zhen

    2017-01-01

    This paper uses experimental investigation and theoretical derivation to study the unified failure mechanism and ultimate capacity model of reinforced concrete (RC) members under combined axial, bending, shear and torsion loading. Fifteen RC members are tested under different combinations of compressive axial force, bending, shear and torsion using experimental equipment designed by the authors. The failure mechanism and ultimate strength data for the four groups of tested RC members under different combined loading conditions are investigated and discussed in detail. The experimental research seeks to determine how the ultimate strength of RC members changes with changing combined loads. According to the experimental research, a unified theoretical model is established by determining the shape of the warped failure surface, assuming an appropriate stress distribution on the failure surface, and considering the equilibrium conditions. This unified failure model can be reasonably and systematically changed into well-known failure theories of concrete members under single or combined loading. The unified calculation model could be easily used in design applications with some assumptions and simplifications. Finally, the accuracy of this theoretical unified model is verified by comparisons with experimental results.

  20. A unified approach for determining the ultimate strength of RC members subjected to combined axial force, bending, shear and torsion.

    Directory of Open Access Journals (Sweden)

    Pu Wang

    Full Text Available This paper uses experimental investigation and theoretical derivation to study the unified failure mechanism and ultimate capacity model of reinforced concrete (RC members under combined axial, bending, shear and torsion loading. Fifteen RC members are tested under different combinations of compressive axial force, bending, shear and torsion using experimental equipment designed by the authors. The failure mechanism and ultimate strength data for the four groups of tested RC members under different combined loading conditions are investigated and discussed in detail. The experimental research seeks to determine how the ultimate strength of RC members changes with changing combined loads. According to the experimental research, a unified theoretical model is established by determining the shape of the warped failure surface, assuming an appropriate stress distribution on the failure surface, and considering the equilibrium conditions. This unified failure model can be reasonably and systematically changed into well-known failure theories of concrete members under single or combined loading. The unified calculation model could be easily used in design applications with some assumptions and simplifications. Finally, the accuracy of this theoretical unified model is verified by comparisons with experimental results.

  1. Ocular torsion associated with infarction in the territory of the anterior inferior cerebellar artery: frequency, pattern, and a major determinant.

    Science.gov (United States)

    Lee, Hyung; Yi, Hyon-Ah; Lee, Seong-Ryong; Lee, Se-Youp; Park, Byung-Rim

    2008-06-15

    Acute ischemic stroke in the distribution of the anterior inferior cerebellar artery (AICA) can cause the vestibular dysfunction in the roll plane of the vestibuloocular reflex with abnormal ocular torsion (OT). There has been no systemic study that carefully investigates the nature of OT that occurs with AICA infarction. To investigate the frequency, the characteristic patterns of OT associated with AICA territory infarction, and the crucial site for determining the direction of OT in AICA territory infarction. We studied 12 consecutive cases of infarction in the territory of the AICA diagnosed by brain MRI. Fundus photography, prism cover test, and subjective visual vertical tilting test were performed to evaluate the function of the otolith system. Pure tone audiogram was also performed to evaluate the function of the auditory system. Nine (75%) of 12 patients exhibited pathological ocular torsion (OT). Two types of pathological OT were found: ipsiversive OT accompanying skew deviation (n=6), and contraversive OT only (n=3). Six patients with ipsiversive OT with skew deviation showed an audiovestibular loss with canal paresis and hearing loss ipsilaterally whereas three patients with contraversive OT without skew deviation had a normal audiovestibular response. In all cases with pathological OT, the direction of the subjective visual vertical tilt corresponded to the direction of the OT. Our findings emphasize that the peripheral vestibular structure with inner ear probably plays a crucial role in determining the direction of OT associated with AICA territory infarction.

  2. Characterization of the dynamic behaviour of ALGOTUF armour steel during impact and in torsion

    Science.gov (United States)

    Bassim, Nabil; Boakye-Yiadom, Solomon; Toussaint, Genevieve; Bolduc, Manon

    2015-09-01

    Algotuf is a new steel which is proposed as a candidate for armour material. To assess this application, a study of the impact properties of this steel was conducted at the University of Manitoba using two types of Hopkinson Bar systems, namely a torsional bar equipment and a direct impact system capable of producing high strain rates and large strains. Stress strain curves for the steels were obtained in pure shear and in compression. Temperatures of 25 ∘C, 200 ∘C and 500 ∘C were used in the testing. Following the testing, a microstructural examination of the specimens tested was carried out to investigate the effect of microstructure on the mechanism of failure of this material. It was found that, above a value of impact momentum corresponding to a high strain rate, adiabatic shear bands are formed. The microscopic examination showed that the initiation of these shear bands corresponded at locations where martensitic laths were present and around regions of maximum shear stresses. Generally, the shear bands act as precursors to the formation of microcracks that may lead to failure. On the other hand, the high strength and formability of the steel makes it suitable for use as an armour material.

  3. Characterization of the dynamic behaviour of ALGOTUF armour steel during impact and in torsion

    Directory of Open Access Journals (Sweden)

    Bassim Nabil

    2015-01-01

    Full Text Available Algotuf is a new steel which is proposed as a candidate for armour material. To assess this application, a study of the impact properties of this steel was conducted at the University of Manitoba using two types of Hopkinson Bar systems, namely a torsional bar equipment and a direct impact system capable of producing high strain rates and large strains. Stress strain curves for the steels were obtained in pure shear and in compression. Temperatures of 25 ∘C, 200 ∘C and 500 ∘C were used in the testing. Following the testing, a microstructural examination of the specimens tested was carried out to investigate the effect of microstructure on the mechanism of failure of this material. It was found that, above a value of impact momentum corresponding to a high strain rate, adiabatic shear bands are formed. The microscopic examination showed that the initiation of these shear bands corresponded at locations where martensitic laths were present and around regions of maximum shear stresses. Generally, the shear bands act as precursors to the formation of microcracks that may lead to failure. On the other hand, the high strength and formability of the steel makes it suitable for use as an armour material.

  4. Strain Localization and Weakening Processes in Viscously Deforming Rocks: Numerical Modeling Based on Laboratory Torsion Experiments

    Science.gov (United States)

    Doehmann, M.; Brune, S.; Nardini, L.; Rybacki, E.; Dresen, G.

    2017-12-01

    Strain localization is an ubiquitous process in earth materials observed over a broad range of scales in space and time. Localized deformation and the formation of shear zones and faults typically involves material softening by various processes, like shear heating and grain size reduction. Numerical modeling enables us to study the complex physical and chemical weakening processes by separating the effect of individual parameters and boundary conditions. Using simple piece-wise linear functions for the parametrization of weakening processes allows studying a system at a chosen (lower) level of complexity (e.g. Cyprych et al., 2016). In this study, we utilize a finite element model to test two weakening laws that reduce the strength of the material depending on either the I) amount of accumulated strain or II) deformational work. Our 2D Cartesian models are benchmarked to single inclusion torsion experiments performed at elevated temperatures of 900 °C and pressures of up to 400 MPa (Rybacki et al., 2014). The experiments were performed on Carrara marble samples containing a weak Solnhofen limestone inclusion at a maximum strain rate of 2.0*10-4 s-1. Our models are designed to reproduce shear deformation of a hollow cylinder equivalent to the laboratory setup, such that material leaving one side of the model in shear direction enters again on the opposite side using periodic boundary conditions. Similar to the laboratory tests, we applied constant strain rate and constant stress boundary conditions.We use our model to investigate the time-dependent distribution of stress and strain and the effect of different parameters. For instance, inclusion rotation is shown to be strongly dependent on the viscosity ratio between matrix and inclusion and stronger ductile weakening increases the localization rate while decreasing shear zone width. The most suitable weakening law for representation of ductile rock is determined by combining the results of parameter tests with

  5. Contrast-enhanced, real-time volumetric ultrasound imaging of tissue perfusion: preliminary results in a rabbit model of testicular torsion

    Science.gov (United States)

    Paltiel, H. J.; Padua, H. M.; Gargollo, P. C.; Cannon, G. M., Jr.; Alomari, A. I.; Yu, R.; Clement, G. T.

    2011-04-01

    Contrast-enhanced ultrasound (US) imaging is potentially applicable to the clinical investigation of a wide variety of perfusion disorders. Quantitative analysis of perfusion is not widely performed, and is limited by the fact that data are acquired from a single tissue plane, a situation that is unlikely to accurately reflect global perfusion. Real-time perfusion information from a tissue volume in an experimental rabbit model of testicular torsion was obtained with a two-dimensional matrix phased array US transducer. Contrast-enhanced imaging was performed in 20 rabbits during intravenous infusion of the microbubble contrast agent Definity® before and after unilateral testicular torsion and contralateral orchiopexy. The degree of torsion was 0° in 4 (sham surgery), 180° in 4, 360° in 4, 540° in 4, and 720° in 4. An automated technique was developed to analyze the time history of US image intensity in experimental and control testes. Comparison of mean US intensity rate of change and of ratios between mean US intensity rate of change in experimental and control testes demonstrated good correlation with testicular perfusion and mean perfusion ratios obtained with radiolabeled microspheres, an accepted 'gold standard'. This method is of potential utility in the clinical evaluation of testicular and other organ perfusion.

  6. Topological invariants and the dynamics of an axial vector torsion field

    International Nuclear Information System (INIS)

    Drechsler, W.

    1983-01-01

    A generalized throry of gravitation is discussed which is based on a Riemann-Cartan space-time, U 4 , with an axial vector torsion field. Besides Einstein's equations determining the metric of the U 4 a system of nonlinear field equations is established coupling an axial vector source current to the axial vector torsion field. The properties of the solutions of these equations are discussed assuming a London-type condition relating the axial current and torsion field. To characterize the solutions use is made of the Euler and Pontrjagin forms and the associated quadratic curvature invariants for the U 4 space-time. It is found that there exists for a Riemann-Cartan space-time a relation between the zeros of the axial vector torsion field and the singularities of the Pontrjagin invariant, which is analogous to the well-known Hopf relation between the zeros of vector fields and the Euler characteristic. (author)

  7. Some aspects of Holst and Nieh-Yan terms in general relativity with torsion

    Energy Technology Data Exchange (ETDEWEB)

    Banerjee, Kinjal, E-mail: kinjal@iucaa.ernet.i [IUCAA, Post Bag 4, Ganeshkhind, Pune, 411 007 (India)

    2010-07-07

    We explore the relation of the Holst term with the Nieh-Yan term in terms of metric variables. We show that the Holst term indeed affects the classical equations of motion in the presence of matter with spin. Therefore, the correct term to add to the Einstein-Hilbert action such that the equations of motion are not affected is the Nieh-Yan term. We then calculate the torsion charge due to this term in the context of a perfect fluid sphere with torsion and show that it vanishes once a horizon is formed but not otherwise. We also show that on adding torsion to general relativity Einstein's equations are no longer holographic in torsion although they continue to be so for the metric.

  8. Seismic behavior of circular reinforced concrete bridge columns under combined loading including torsion.

    Science.gov (United States)

    2009-12-01

    Reinforced concrete (RC) columns of skewed and curved bridges with unequal spans and column heights can be subjected to : combined loading including axial, flexure, shear, and torsion loads during earthquakes. The combination of axial loads, shear : ...

  9. Optimal design of a magneto-rheological brake absorber for torsional vibration control

    International Nuclear Information System (INIS)

    Nguyen, Q H; Choi, S B

    2012-01-01

    This research presents an optimal design of a magneto-rheological (MR) brake absorber for torsional vibration control of a rotating shaft. Firstly, the configuration of an MR brake absorber for torsional vibration control of a rotating shaft system is proposed. Then, the braking torque of the MR brake is derived based on the Bingham plastic model of the MR fluid. By assuming that the behaviour of the MR brake absorber is similar to that of a dry friction torsional damper, the optimal braking torque to control the torsional vibration is determined and validated by simulation. The optimal design problem of the MR brake absorber is then developed and a procedure to solve the optimal problem is proposed. Based on the proposed optimal design procedure, the optimal design of a specific rotating shaft system is performed. Vibration control performance of the shaft system employing the optimized MR brake absorber is then investigated through simulation and discussion on the results is given. (paper)

  10. Effect of torsion moment on failure bending moment for circumferentially cracked pipe

    International Nuclear Information System (INIS)

    Li, Yinsheng; Hasegawa, Kunio; Ida, Wataru; Hoang, Phuong H.; Bezensek, Bostjan

    2010-01-01

    When a crack is detected in a stainless steel pipe during in-service inspection, the limit load criterion given in the codes such as JSME Rules on Fitness-for-Service for Nuclear Power Plants or ASME Boiler and Pressure Vessel Code Section XI can be applied to evaluate the integrity of the pipe. However, in the current codes, the limit load criterion is only provided considering pressure and bending moment. The torsion moment is not considered, although torsion moment does exist in the nuclear power piping system. In this paper, finite element analyses are carried out for stainless steel pipe containing a circumferential surface crack under the combination of bending moment and torsion moment, considering different pipe dimensions and flaw sizes. Based upon the analysis results, a plastic collapse estimation method is proposed considering the existence of the torsion moment and its magnitude, and this method make it possible to evaluate the integrity of the pipe for general loading conditions. (author)

  11. Optimum Design of Composite Sandwich Structures Subjected to Combined Torsion and Bending Loads

    Science.gov (United States)

    Li, Xiang; Li, Gangyan; Wang, Chun H.; You, Min

    2012-06-01

    This research is motivated by the increase use of composite sandwich structures in a wide range of industries such as automotive, aerospace and civil infrastructure. To maximise stiffness at minimum weight, the paper develops a minimum weight optimization method for sandwich structure under combined torsion and bending loads. We first extend the minimum-weight design of sandwich structures under bending load to the case of torsional deformation and then present optimum solutions for the combined requirements of both bending and torsional stiffness. Three design cases are identified for a sandwich structure required to meet multiple design constraints of torsion and bending stiffness. The optimum solutions for all three cases are derived. To illustrate the newly developed optimum design solutions, numerical examples are presented for sandwich structures made of either isotropic face skins or orthotropic composite face skins.

  12. The gravitational and electromagnetic fields in a space-time with torsion

    International Nuclear Information System (INIS)

    Oancea, S.

    1992-01-01

    The equation of gravitational and electromagnetic field in a space-time with torsion are discussed. In a particular case the equations that define the metric and electromagnetic field are obtained. (Author)

  13. Optimal design of a magneto-rheological brake absorber for torsional vibration control

    Science.gov (United States)

    Nguyen, Q. H.; Choi, S. B.

    2012-02-01

    This research presents an optimal design of a magneto-rheological (MR) brake absorber for torsional vibration control of a rotating shaft. Firstly, the configuration of an MR brake absorber for torsional vibration control of a rotating shaft system is proposed. Then, the braking torque of the MR brake is derived based on the Bingham plastic model of the MR fluid. By assuming that the behaviour of the MR brake absorber is similar to that of a dry friction torsional damper, the optimal braking torque to control the torsional vibration is determined and validated by simulation. The optimal design problem of the MR brake absorber is then developed and a procedure to solve the optimal problem is proposed. Based on the proposed optimal design procedure, the optimal design of a specific rotating shaft system is performed. Vibration control performance of the shaft system employing the optimized MR brake absorber is then investigated through simulation and discussion on the results is given.

  14. Low success rate of salvage surgery for testicular torsion in newborns

    DEFF Research Database (Denmark)

    Jensen, Rie Overgaard; Pedersen, Mark Ellebæk; Rasmussen, Lars

    2015-01-01

    INTRODUCTION: Testicular torsion within the first 30 days of life is rare. The treatment is controversial, and the prognosis for testis viability varies from 0 to 40% in the literature. The aim of this study was to review our institutional results for surgery for testicular torsion in the neonatal...... period with a special focus on salvage surgery. METHODS: Patient records were reviewed for all children in the age up to 30 days who were operated for testicular torsion at our hospital during the past 20 years. RESULTS: A total of 13 patients were included, two with bilateral affection. Emergency...... was only salvaged in cases with urgent surgery at symptom recognition. Cases that presented within the first day of life resulted in a non-salvageable testis despite emergency surgery. The reason may be prenatal torsion. Doctor's delay was common for this rare disease. FUNDING: not relevant. TRIAL...

  15. Contrast-enhanced ultrasonographic findings in three dogs with lung lobe torsion.

    Science.gov (United States)

    Caivano, Domenico; Birettoni, Francesco; Bufalari, Antonello; De Monte, Valentina; Angeli, Giovanni; Giorgi, Maria Elena; Patata, Valentina; Porciello, Francesco

    2016-03-01

    Lung lobe torsion is rare but life-threatening condition in the dog. Thoracic radiographs and conventional ultrasonography cannot be conclusive for the diagnosis, and computed tomography is useful but is limited by cost and availability. This report describes the findings of contrast-enhanced ultrasonography in 3 dogs with lung lobe torsion. Contrast-enhanced ultrasonography showed the absence or reduction of pulmonary vascularization secondary to twisting of the lung lobe around its bronchovascular pedicle in all three dogs. Moreover, contrast-enhanced ultrasonography distinguished partial pulmonary atelectasis from a lung lobe torsion. These preliminary results suggest that contrast-enhanced ultrasonography can improve the accuracy of conventional ultrasonography for detection of pulmonary blood flow compromise in dogs with lung lobe torsion.

  16. Harmonic spinors of Dirac operator of connection with torsion in dimension 4

    International Nuclear Information System (INIS)

    Dalakov, P.; Ivanov, S.

    2000-06-01

    It is shown that the existence of parallel (-)-spinor with respect to a metric connection with totally skew-symmetric torsion requires more local restriction than the existence of parallel (+)-spinor. It is proved that every harmonic spinor with respect to the Dirac operator of this connection on a compact four dimensional spin Riemannian manifold is parallel with respect to a naturally arising metric connection with totally skew-symmetric torsion and all these spaces are classified up to a conformal transformations. (author)

  17. Torsion - Vibration Couplings in the CH{_3}OO{\\cdot} Radical

    Science.gov (United States)

    Huang, Meng; Miller, Terry A.; McCoy, Anne B.; Hsu, Kuo-Hsiang; Huang, Yu-Hsuan; Lee, Yuan-Pern

    2016-06-01

    A partially rotationally resolved infrared spectrum of CH{_3}OO{\\cdot} in the CH stretch region has been reported. The rotational contour of the {ν_2} CH stretch band in the experimental spectrum can be simulated with an asymmetric rotor model. The simulation shows good agreement with the experimental spectrum except that the broadening of the Q-branch in the experimental spectrum remains unexplained. This broadening is likely due to the sequence band transitions from the torsionally excited levels populated at room temperature to combination levels involving the CH stretch and the same number of torsional quanta. A four dimension model involving three CH stretches and the CH{_3} torsion is applied to the CH{_3}OO{\\cdot} radical to obtain the frequencies and intensities of the vibrational transitions in the CH stretch region. Based on these calculations, the torsional sequence bands are calculated to be slightly shifted from the origin band, because of the couplings between the CH stretches and CH{_3} torsion, thereby causing the apparent broadening observed for the {ν_2} fundamental. Due to the accidental degeneracy of two different CH stretch and CH{_3} torsion combination levels which differ by one quantum in the torsional excitation, the frequencies of the torsional sequence bands will be very sensitive to details of the potential, which makes the shifts difficult to precisely predict with electronic structure calculations. Complementary analyses are now underway for the other two CH stretch vibrational bands, {ν_1} and {ν_9}. K.-H. Hsu, Y.-H. Huang, Y.-P. Lee, M. Huang, T. A. Miller and A. B. McCoy J. Phys. Chem. A, in press, DOI: 10.1021/acs.jpca.5b12334

  18. Case series on testicular torsion: an educational emergency for sub-Saharan Africa

    OpenAIRE

    Baruga, Evarist; Guyton Munabi, Ian

    2013-01-01

    Testicular torsion remains a common surgical emergency of adolescent males presenting with sudden onset of intense scrotal pain in Africa. While the magnitude of testicular torsion is not known it has been identified as a cause of male infertility. Testicular loss in Africa is directly related to delay in surgery and the referral patterns at the point of first contact with health workers. This paper sets out to demonstrate the importance of the patient's age in the diagnosis of testicular tor...

  19. The rotational axis of the tibia and relationship to the tibial torsion in varus osteoarthritic knee.

    Science.gov (United States)

    Chotanaphuti, Thanainit; Srisawasdi, Ruthasiri; Rattanaprichavej, Piti; Laoruengthana, Artit

    2012-10-01

    A transepicondylar axis is a useful reference for femoral component rotation and is demonstrated as a functional flexion-extension axis of a knee. Conversely, a rotational orientation of the tibial component was less clearly demonstrated and many anatomical landmarks were proposed. It has been reported that Asian people had more medial torsion of the tibia particularly with an osteoarthritic knee. The present study aims to address the relationship between the torsion variation of the tibia and the rotational axis of the tibia. Forty knees of 32 women (mean age of 73.3) with varus osteoarthritis underwent a preoperative CT images to identify a surgical epicondylar axis, an axis perpendicular to this line (femoral reference line), lines connecting between the PCL insertion and 3 reference point on the patellar tendon, an AP axis of the ankle and a tibial torsion angle. The mean value of the angle between the line connecting the PCL insertion and 3 different point of the patellar tendon including the medial border medial one-third and middle of the patellar tendon and the femoral reference line was -4.22, +4.37 and +8.47 degree, respectively. The mean of a tibial torsion angle was +16.51 degree. There were 6 cases having the femoral reference line rotated internally to the medial border of the patellar tendon and having less torsion angle (medial tibial torsion) with a mean of +13.78 degree. The femoral reference line in the Thai osteoarthritic knee is passed between medial edge of patellar tendon and medial 1/3 of patellar tendon. This line rotates more internally compared with the patellar tendon if the degree of medial tibial torsion is more severe. An excessive externally rotated tibial component when using the patellar tendon as guidance should be avoided in the knee presenting with medial tibial torsion.

  20. Intraoperative monitoring of torsion to prevent vertical deviations during augmented vertical rectus transposition surgery.

    Science.gov (United States)

    Holmes, Jonathan M; Hatt, Sarah R; Leske, David A

    2012-04-01

    Total transposition of the superior and inferior rectus muscle laterally, with augmentation sutures, may be complicated by induction of an undesirable vertical deviation. Induced vertical misalignment may be associated with changes in torsion. We have developed a simple method to monitor intraoperative torsion that may reduce the incidence of vertical deviations. We reviewed consecutive cases of total abducens palsy or esotropic Duane syndrome treated with augmented lateral transposition of the superior and inferior rectus muscles, where the 12 o'clock and 6 o'clock intraoperative positions were initially marked with a dot at the limbus using a surgical pen. The location of the marks was monitored during tying of the augmentation sutures; changes in torsion were monitored intraoperatively. Records of 9 cases of augmented vertical rectus transposition were reviewed. On the basis of intraoperative assessment of torsion, by observing the position of preplaced limbal dots, the inferior rectus augmentation suture was tied less tightly than the superior rectus suture, leaving a gap of 1 to 3 mm between the inferior and lateral rectus muscles in 8 of 9 cases. The augmentation suture was totally removed in 1 case. After these intraoperative adjustments, there was no induced intraoperative torsion, whereas further tightening of the inferior suture induced extorsion. Six weeks postoperatively, 8 of 9 patients did not experience a symptomatic vertical deviation. When performing augmented transposition procedures, intraoperative monitoring of torsion may reduce the incidence of inadvertent vertical deviations and torsion. This technique may also be useful in other cases where correction or avoidance of torsion is needed. Copyright © 2012 American Association for Pediatric Ophthalmology and Strabismus. Published by Mosby, Inc. All rights reserved.

  1. Capacitively-coupled differential position detection in the development of a high-sensitivity torsion balance

    Science.gov (United States)

    Rackson, Charles; Watt, Alex; Kim, Woo-Joong; Seattle University Team

    2015-03-01

    We report on the development of a high-sensitivity torsion balance using a capacitively-coupled Wheatstone Bridge. The torsion balance will be employed to measure the Casimir Force, with a particular emphasis on the surface patch effects that are ubiquitous on metallic surfaces. We will show that these effects also play a significant role in another class of experiments involving quantum-point contacts between two metal wires.

  2. TORSION TESTIS : ROLE OF COLOR DOPPLER : A STUDY OF 50 CASES

    Directory of Open Access Journals (Sweden)

    Anand

    2015-09-01

    Full Text Available BACKGROUND: T orsion testis is one of the catast r ophic conditions in children and young a d u lts. Traditionally the diagnosis was made clinical presentation and suspicion. Critical decision making is essential to save the testis . OBJECTIVE: To study the usefu lness and efficacy of Doppler ultrasound in correctly diagnosing acute scrotal conditions in children and young adults to save the testis and to avoid negative explorations. METHODS: Over a period of two years 50 patients with acute scrotum were admitted i n general surgery department who underwent Doppler ultrasound scrotum and its efficacy in correctly diagnosing the pathology was analysed. RESULTS: 50 patients with age group <25 years were included in study. Scrotal pain was the most frequent presenting s ymptom of acute scrotum (98% followed by Swelling of the hemiscrolum on the involved side present in 86% of the patients. Doppler ultrasound showed torsion of testis in 18 patients. On Scrotal exploration, torsion of spermatic cord was confirmed in 16 pat ients, one patient had torsion of appendix of testis and the other had Epididymo - orchitis. Thus the sensitivity and specificity of Doppler ultrasonography for testicular torsion was 86.9% and 92.6% respectively. 2 patients with equivocal Doppler findings, but strong clinical suspicion of testicular torsion were explored, and testis was found to be torsed in both two patients. Doppler ultrasonography showed Epididymo - orchitis in 22 patients, torsion of testicular appendage in 2 patients, Idiopathic scrotal edema in one, and in 5 pts no significant pathology found. All twenty patients of epididymo - orchitis, two patients of torsion of testicular appendage, and one patient of idiopathic scrotal edema were managed conservatively. At three weeks follow up, all th e patients were free of symptoms. The sensitivity and specificity of Doppler ultrasonography for epididymo - orchitis was 95% and 100% respectively. CONCLUSIONS: color

  3. Torsion of the accessory spleen with infarction : CT features in a case report

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Jung Kyung; Lee, Jun Sik; Kim, Mee Eun; Pyun, Hae Wook; Lee, Il Gi; Lee, Jong Gil; Kim, Hee Jin; Kim, Ik Su [Fatima Hospital, Taegu (Korea, Republic of)

    2000-05-01

    Torsion of the accessory spleen is a rare entity that can have variable clinical presentations. We report case involving an 11-year-old boy with severe abdominal pain and a mass that was found to be due to infarction of the accessory spleen, which was twisted on its pedicle. CT revealed a low-attenuating mass with peripheral inflammatory changes in the left upper abdomen. The mass was pathologically confirmed as torsion of the accessory spleen with infarction. (author)

  4. Self-annealing in a two-phase Pb-Sn alloy after processing by high-pressure torsion

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Nian Xian [Materials Research Group, Faculty of Engineering and the Environment, University of Southampton, Southampton SO17 1BJ (United Kingdom); Chinh, Nguyen Q. [Department of Materials Physics, Eötvös Loránd University, 1117 Budapest, Pázmány Péter s. 1/A. (Hungary); Kawasaki, Megumi [Division of Materials Science and Engineering, Hanyang University, Seoul 133-791 (Korea, Republic of); Departments of Aerospace & Mechanical Engineering and Materials Science, University of Southern California, Los Angeles, CA 90089-1453 (United States); Huang, Yi, E-mail: Y.Huang@soton.ac.uk [Materials Research Group, Faculty of Engineering and the Environment, University of Southampton, Southampton SO17 1BJ (United Kingdom); Langdon, Terence G. [Materials Research Group, Faculty of Engineering and the Environment, University of Southampton, Southampton SO17 1BJ (United Kingdom); Departments of Aerospace & Mechanical Engineering and Materials Science, University of Southern California, Los Angeles, CA 90089-1453 (United States)

    2016-06-01

    A Pb-62% Sn two-phase eutectic alloy was processed by high-pressure torsion (HPT) and stored at room temperature (RT) to investigate the occurrence of self-annealing. The microstructural characteristics and mechanical properties were recorded during self-annealing using scanning electron microscopy, tensile testing and nanoindentation. Processing by HPT produces a weakening effect but storage at RT leads to a gradual increase in the hardness together with significant grain growth. Nanoindentation tests were performed by applying both the indentation depth-time (h-t) relationship at the holding stage and the hardness, H, at various loading rates in order to explore the evolution of the strain rate sensitivity (SRS), m. The results obtained by tensile testing and nanoindentation are consistent despite the large difference in the volumes of the examined regions, thereby confirming the validity of using nanoindentation to measure the strain rate sensitivity.

  5. Investigations on Torsion of the Two-Chords Single Laced Members

    Directory of Open Access Journals (Sweden)

    Lorkowski Paweł

    2017-06-01

    Full Text Available The paper presents experimental and numerical studies to determine the equivalent second moment of area of the uniform torsion of the two-chord steel single laced members. The members are used as poles of railway traction network gates, and steel columns of framed buildings as well. The stiffness of uniform torsion of this kind of columns allows to the determine the critical loads of the spatial stability. The experimental studies have been realized on a single - span members with rotation arrested at their ends, loaded by a torque applied at the mid-span. The relationship between angle of rotation of the considered cross-section and the torque has been determined. Appropriate numerical model was created in the ABAQUS program, based on the finite element method. A very good compatibility has been observed between experimental and numerical studies. The equivalent second moment of area of the uniform torsion for analysed members has been determined by comparing the experimental and analytical results to those obtained from differential equation of non-uniform torsion, based on Vlasov’s theory. Additionally, the parametric analyses of similar members subjected to the uniform torsion, for the richer range of cross-sections have been carried out by the means of SOFiSTiK program. The purpose of the latter was determining parametrical formulas for calculation of the second moment of area of uniform torsion.

  6. Investigations on Torsion of the Two-Chords Single Laced Members

    Science.gov (United States)

    Lorkowski, Paweł; Gosowski, Bronisław

    2017-06-01

    The paper presents experimental and numerical studies to determine the equivalent second moment of area of the uniform torsion of the two-chord steel single laced members. The members are used as poles of railway traction network gates, and steel columns of framed buildings as well. The stiffness of uniform torsion of this kind of columns allows to the determine the critical loads of the spatial stability. The experimental studies have been realized on a single - span members with rotation arrested at their ends, loaded by a torque applied at the mid-span. The relationship between angle of rotation of the considered cross-section and the torque has been determined. Appropriate numerical model was created in the ABAQUS program, based on the finite element method. A very good compatibility has been observed between experimental and numerical studies. The equivalent second moment of area of the uniform torsion for analysed members has been determined by comparing the experimental and analytical results to those obtained from differential equation of non-uniform torsion, based on Vlasov's theory. Additionally, the parametric analyses of similar members subjected to the uniform torsion, for the richer range of cross-sections have been carried out by the means of SOFiSTiK program. The purpose of the latter was determining parametrical formulas for calculation of the second moment of area of uniform torsion.

  7. [Posttraumatic torsional deformities of the forearm : Methods of measurement and decision guidelines for correction].

    Science.gov (United States)

    Blossey, R D; Krettek, C; Liodakis, E

    2018-03-01

    Forearm fractures are common in all age groups. Even if the adjacent joints are not directly involved, these fractures have an intra-articular character. One of the most common complications of these injuries is a painful limitation of the range of motion and especially of pronation and supination. This is often due to an underdiagnosed torsional deformity; however, in recent years new methods have been developed to make these torsional differences visible and quantifiable through the use of sectional imaging. The principle of measurement corresponds to that of the torsion measurement of the lower limbs. Computed tomography (CT) or magnetic resonance imaging (MRI) scans are created at defined heights. By searching for certain landmarks, torsional angles are measured in relation to a defined reference line. A new alternative is the use of 3D reformation models. The presence of a torsional deformity, especial of the radius, leads to an impairment of the pronation and supination of the forearm. In the presence of torsional deformities, radiological measurements can help to decide if an operation is needed or not. Unlike the lower limbs, there are still no uniform cut-off values as to when a correction is indicated. Decisions must be made together with the patient by taking the clinical and radiological results into account.

  8. Intraoperative performance and postoperative outcome comparison of longitudinal, torsional, and transversal phacoemulsification machines.

    Science.gov (United States)

    Christakis, Panos G; Braga-Mele, Rosa M

    2012-02-01

    To compare the intraoperative performance and postoperative outcomes of 3 phacoemulsification machines that use different modes. Kensington Eye Institute, Toronto, Ontario, Canada. Comparative case series. This chart and video review comprised consecutive eligible patients who had phacoemulsification by the same surgeon using a Whitestar Signature Ellips-FX (transversal), Infiniti-Ozil-IP (torsional), or Stellaris (longitudinal) machine. The review included 98 patients. Baseline characteristics in the groups were similar; the mean nuclear sclerosis grade was 2.0 ± 0.8. There were no significant intraoperative complications. The torsional machine averaged less phacoemulsification needle time (83 ± 33 seconds) than the transversal (99 ± 40 seconds; P=.21) or longitudinal (110 ± 45 seconds; P=.02) machines; the difference was accentuated in cases with high-grade nuclear sclerosis. The torsional machine had less chatter and better followability than the transversal or longitudinal machines (Pmachines had better anterior chamber stability than the transversal machine (Pmachine yielded less central corneal edema than the transversal (Pmachines, corresponding to a smaller increase in mean corneal thickness (torsional 5%, transversal 10%, longitudinal 12%; P=.04). Also, the torsional machine had better 1-day postoperative visual acuities (Pmachines were effective with no significant intraoperative complications. The torsional machine outperformed the transversal and longitudinal machines, with a lower mean needle time, less chatter, and improved followability. This corresponded to less corneal edema 1 day postoperatively and better visual acuity. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  9. Microstructure and texture evolution in a magnesium alloy during processing by high-pressure torsion

    Directory of Open Access Journals (Sweden)

    Yi Huang

    2013-06-01

    Full Text Available Magnesium alloys often exhibit cracking and segmentation after equal-channel angular pressing (ECAP at room temperature. With torsion shear deformation and a hydrostatic stress, high-pressure torsion (HPT has an advantage over ECAP in the processing of hard-to-deform materials like magnesium alloys at room temperature. In this report, HPT was used on extruded AZ31 Mg alloy at temperatures of 296, 373 and 473 K for 1 and 5 turns. After HPT processing, the hcp crystal c-axis rotated from the disc (r,θ plane towards the torsion axis. The angle between the c-axis and the torsion axis (Φ has a relationship with the HPT processing temperature. It was found that the c-axis was 10º from the torsion axis at 296 and 373 K but 5º from the torsion axis at 473 K. The activity of the basal slip and the twinning exert significant contributions to the deformation. Microstructural features such as the grain size and grain size distributions were examined and correlated with the mechanical properties through the microhardness values.

  10. Torsion of a normal ovary in the third trimester of pregnancy: a case report

    Directory of Open Access Journals (Sweden)

    Silja Arumugam

    2008-12-01

    Full Text Available Abstract Introduction Adnexal torsion in advanced pregnancy is an uncommon emergency. Torsion usually occurs in ovaries with functional cysts or tumors. It is uncommon for a normal-sized ovary to undergo torsion in advanced gestation. We report torsion of a normal-sized ovary in the third trimester of pregnancy, most probably the first case report of its kind in the English-language literature. Case presentation A 32-year-old Omani woman at 32-weeks gestation (gravida 2 para 1 was admitted with right iliac fossa pain, nausea and vomiting of 2 days duration, as well as a history of a similar episode one month earlier. On examination, a provisional diagnosis of appendicitis was made. Laparotomy revealed, however, that the right ovary was gangrenous and had undergone torsion. Conclusion Adnexal torsion, though rare, should be kept in mind in the differential diagnosis of lower abdominal pain in advanced gestation. Although in our patient, the affected ovary could not be saved, an early diagnosis using imaging like Doppler of the adnexae will enable early intervention to save the ovaries of the patient, especially in young women.

  11. Non-minimal coupling of torsion-matter satisfying null energy condition for wormhole solutions

    Energy Technology Data Exchange (ETDEWEB)

    Jawad, Abdul; Rani, Shamaila [COMSATS Institute of Information Technology, Department of Mathematics, Lahore (Pakistan)

    2016-12-15

    We explore wormhole solutions in a non-minimal torsion-matter coupled gravity by taking an explicit non-minimal coupling between the matter Lagrangian density and an arbitrary function of the torsion scalar. This coupling describes the transfer of energy and momentum between matter and torsion scalar terms. The violation of the null energy condition occurred through an effective energy-momentum tensor incorporating the torsion-matter non-minimal coupling, while normal matter is responsible for supporting the respective wormhole geometries. We consider the energy density in the form of non-monotonically decreasing function along with two types of models. The first model is analogous to the curvature-matter coupling scenario, that is, the torsion scalar with T-matter coupling, while the second one involves a quadratic torsion term. In both cases, we obtain wormhole solutions satisfying the null energy condition. Also, we find that the increasing value of the coupling constant minimizes or vanishes on the violation of the null energy condition through matter. (orig.)

  12. Torsional behaviour of reinforced concrete beams with ferrocement U-jacketing—Experimental study

    Directory of Open Access Journals (Sweden)

    Gopal Charan Behera

    2016-06-01

    Full Text Available Wrapping technology is one of the effective ways of strengthening concrete elements. Several researchers reported the effectiveness of Glass fiber reinforced polymers and carbon fiber reinforced polymers for improving the strength of the concrete elements. Wrapping on three sides is one of the effective methods for strengthening the beams supporting slabs. Available literatures on the strength enhancement of “U” wrapped concrete elements subjected to torsional loads do not give a detailed insight, whereas this investigation is an attempt to address the issues with ferrocement “U” wrap. Ferrocement “U” wraps are preferred over FRPs because of its cost factor. The “U” wraps are found to provide better torque carrying capacity under all states of torsion while under reinforced members provide better toughness over other states of torsion. Similarly completely over reinforced beams provide more torque resisting capacity than the others. Increase of torsional capacity is more prominent in states of torsion while improvement in torsional strength with number of mesh layers in ferrocement “U” wrap is minimal.

  13. Torsional method for evaluating hair damage and performance of hair care ingredients.

    Science.gov (United States)

    Persaud, D; Kamath, Y K

    2004-01-01

    In this study, we have developed a single hair fiber torsional pendulum method to determine the role of the cuticle and the cortex on torsional properties with respect to fiber cross-sectional area, fiber rigidity, and energy dissipation at 65% RH and in the wet state. Our results demonstrate that in fine diameter fibers with a high cuticle-to-cortex ratio, the cuticula exert a significant effect on the torsional deformation behavior of hair fibers at both normal humidities and in the wet condition. In addition, our data indicate that energy dissipation is confined to fibers with a high cuticle-to-cortex ratio, and the amount of energy dissipated becomes more pronounced with increasing water content. The torsional properties of hair spray-treated fibers suggest that the deposited hair spray film masks the properties of the base fiber and imparts its own dissipative character to the measurement. Since tensile mechanical properties are often used to make claims about the performance of hair care products, we have compared the results obtained from torsional and tensile measurements on over-processed bleached hair fibers conditioned with Polyquaternium-10 and cetyl trimethylammonium bromide (CETAB) to evaluate which method is more advantageous. Our data demonstrate that torsional measurements can distinguish hair care products which reinforce the cuticle from those which affect the cortex, while tensile measurements showed no significant differences.

  14. Neonatal Testicular Torsion After Cesarean Section With Spinal Anesthesia: a Presentation of Two Cases

    Directory of Open Access Journals (Sweden)

    Peyman Rahmanizadeh

    2009-11-01

    Full Text Available Testicular torsion is a medical emergency appearing at any age, the prevalence of which in the neonatal period comprises 10% of the whole cases occurring at any  point in life.Among all the cases being diagnosed at birth,70% has occurred in the prenatal period and 30% in the neonatal period.Generally, the most common symptoms of testicular torsion during postnatal period include acute pain and swelling of the testis, but in the neonatal period it is often manifested by firmness and swelling of  the testicle. Accordingly, careful attention of the physician and the medical staff while examining the newborn results in quick diagnosis and timely medical treatment  of the torsion.This medical intervention prevents irreversible necrosis of the affected testis-the main consequence of the torsion-and helps to restore its function.The major purpose of this study was to draw the attention of physicians and medical  teams to prompt diagnosis of testicular torsion.This study presents two newborn  babies with testicular torsion,diagnosed at early hours after delivery,who underwent surgical treatment within first 8-10 hours after birth. 

  15. Ocular torsion as a complication of scleral buckle procedures for retinal detachments.

    Science.gov (United States)

    Cooper, L L; Harrison, S; Rosenbaum, A L

    1998-10-01

    Strabismus can occur in as many as 30% of patients after scleral buckle procedures for retinal detachments. Most previous case series have reported on horizontal and vertical deviations. This study examines the frequency of torsion after scleral buckle procedures, the abnormalities of extraocular muscles seen during strabismus surgery, and the surgical procedures effective in improving torsion. A chart review examined the records of all patients coming to a strabismus referral practice with diplopia reported > or =6 months after scleral buckle procedures. Forty-six percent of patients with diplopia after scleral buckle operations had torsion (88% extorsion, 12% intorsion). The 2 mechanisms that caused extorsion most frequently were inadvertent production of a superior oblique muscle palsy and tightening of the inferior rectus muscle from the underlying scleral buckle. Other mechanisms of extorsion were also seen. The mechanism for production of intorsion was scarring of the superior oblique muscle to the nasal border of the insertion of the superior rectus muscle. Surgical procedures were successful in reducing torsion 4 degrees or more in 59% of cases. In patients undergoing surgery for torsion after a scleral buckle procedure, exploration of the superior oblique muscle and the inferior rectus muscle may yield information about the mechanism involved in the production of the torsion.

  16. Research on torsional friction behavior and fluid load support of PVA/HA composite hydrogel.

    Science.gov (United States)

    Chen, Kai; Zhang, Dekun; Yang, Xuehui; Cui, Xiaotong; Zhang, Xin; Wang, Qingliang

    2016-09-01

    Hydrogels have been extensively studied for use as synthetic articular cartilage. This study aimed to investigate (1) the torsional friction contact state and the transformation mechanism of PVA/HA composite hydrogel against CoCrMo femoral head and (2) effects of load and torsional angle on torsional friction behavior. The finite element method was used to study fluid load support of PVA/HA composite hydrogel. Results show fluid loss increases gradually of PVA/HA composite hydrogel with torsional friction time, leading to fluid load support decreases. The contact state changes from full slip state to stick-slip mixed state. As the load increases, friction coefficient and adhesion zone increase gradually. As the torsional angle increases, friction coefficient and slip trend of the contact interface increase, resulting in the increase of the slip zone and the reduction of the adhesion zone. Fluid loss increases of PVA/HA composite hydrogel as the load and the torsional angle increase, which causes the decrease of fluid load support and the increase of friction coefficient. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Development of a method for measuring femoral torsion using real-time ultrasound

    International Nuclear Information System (INIS)

    Hafiz, Eliza; Hiller, Claire E; Nightingale, E Jean; Eisenhuth, John P; Refshauge, Kathryn M; Nicholson, Leslie L; Clarke, Jillian L; Grimaldi, Alison

    2014-01-01

    Excessive femoral torsion has been associated with various musculoskeletal and neurological problems. To explore this relationship, it is essential to be able to measure femoral torsion in the clinic accurately. Computerized tomography (CT) and magnetic resonance imaging (MRI) are thought to provide the most accurate measurements but CT involves significant radiation exposure and MRI is expensive. The aim of this study was to design a method for measuring femoral torsion in the clinic, and to determine the reliability of this method. Details of design process, including construction of a jig, the protocol developed and the reliability of the method are presented. The protocol developed used ultrasound to image a ridge on the greater trochanter, and a customized jig placed on the femoral condyles as reference points. An inclinometer attached to the customized jig allowed quantification of the degree of femoral torsion. Measurements taken with this protocol had excellent intra- and inter-rater reliability (ICC 2,1  = 0.98 and 0.97, respectively). This method of measuring femoral torsion also permitted measurement of femoral torsion with a high degree of accuracy. This method is applicable to the research setting and, with minor adjustments, will be applicable to the clinical setting. (paper)

  18. Seismic response analysis of nuclear reactor buildings under consideration of soil-structure interaction with torsional behavior

    International Nuclear Information System (INIS)

    Mizuno, N.; Iida, T.; Tsushima, Y.; Araki, T.; Nojima, O.

    1977-01-01

    In this paper, the seismic response analysis is described in detail for estimating the soil-structure interaction effects with the torsional behavior. The analytical method is firstly shown for estimating the stiffness of reactor building by the bending-shear and torsion theory of the thin wall sections in regard to the behavior of structure. The three-dimensional behavior of structure can be obtained more briefly and simply by the proposed method. Secondly, the dynamical soil-foundation coefficient for estimating the dissipation of vibrational energy on the ground is derived by H. Tajimi's theory which is based on a solution of the propagation of seismic waves caused by point excitation on the surface of the elastic half-space medium. The above results give the vibrational impedances of the soil-foundation corresponding to the static soil coefficient, which is defined to the excitation force in the frequency domain. In order to analyze to the equivalues of reactor building, the authors thirdly attempt to approximate the dynamic soil-foundation coefficient as the frequency transfer function of displacement. The complex damping is used for more suitably estimating the elastic structural damping effects of structure. The regression analysis of many degrees of freedom is fourthly attempted for estimating the natural periods annd equivalent viscous damping ratios directly from the experimental results by the forced vibrational test performed in 1974. The analytical results are finally shown for simulating and comparing with the above-mentioned experimental results

  19. Effects of toughness anisotropy and combined tension, torsion, and bending loads on fracture behavior of ferritic nuclear pipe

    International Nuclear Information System (INIS)

    Mohan, R.; Marschall, C.; Krishnaswamy, P.; Brust, F.; Ghadiali, N.; Wilkowski, G.

    1995-04-01

    This topical report summarizes the work on angled crack growth and combined loading effects performed within the Nuclear Regulatory Commission's research program entitled open-quotes Short Cracks in Piping and Piping Weldsclose quotes. The major impetus for this work stemmed from the observation that initial circumferential cracks in carbon steel pipes exhibited angular crack growth. This failure mode was little understood, and the effect of angled crack growth from an initially circumferential crack raised questions of how pipes under combined loading with torsional stresses would behave. There were three major conclusions from this work. The first was that virtually all ferritic nuclear pipes will have toughness anisotropy. The second was that the ratio of the normalized crack driving force (as a function of angle) to the normalized toughness (also as a function of the angle of crack growth) showed that there was an equal likelihood of cracks growing at any angle between 25 and 65 degrees. This agreed with the scatter of crack growth angles observed in pipe tests. Third, for combined loads with torsional stresses, an effective moment allows pure bending analyses to be used up to crack initiation. Crack opening area under combined loads could also be determined in this mariner

  20. Investigation of slow crack growth in dense hydroxyapatite using the double torsion method

    Energy Technology Data Exchange (ETDEWEB)

    Benaqqa, C.; Saadaoui, M. [INSA de Lyon, Villeurbanne (France). GEMPPM; Ecole Mohammadie d' Ingenieur (EMI), Rabat (Morocco); Chevalier, J.; Fantozzi, G. [INSA de Lyon, Villeurbanne (France). GEMPPM

    2002-07-01

    Few investigations devoted to the mechanical properties of hydroxyapatite have shown that these ceramics were sensitive to slow crack growth and fatigue, mainly by so-called static or dynamic fatigue tests. Hydroxyapatite was shown to present reduced lifetime under stress. In this work, double torsion tests were performed to investigate slow crack growth behavior of dense hydroxyapatite materials. The goal was here to obtain the crack rate (V) versus stress intensity factor (K{sub I}) law, which is the intrinsic crack propagation law of a given ceramic. The V-K{sub I} curve of hydroxyapatite is composed of three distinct stages, related to a stress corrosion mechanism by water molecules. Crack propagation occurs over a wide range of stress intensity factors, well below the toughness, meaning that hydroxyapatite is highly sensitive to stress corrosion. This could be explained by the fact that hydroxyapatite ceramics contain hydroxyl groups (HAP: Ca{sub 10}(PO{sub 4}){sub 6}(OH){sub 2}), favouring water adsorption on the crack surface and thus a strong decrease of surface energy in the presence of water. (orig.)