WorldWideScience

Sample records for glass syringe filters

  1. A rapid and economic in-house DNA purification method using glass syringe filters.

    Directory of Open Access Journals (Sweden)

    Yun-Cheol Kim

    Full Text Available BACKGROUND: Purity, yield, speed and cost are important considerations in plasmid purification, but it is difficult to achieve all of these at the same time. Currently, there are many protocols and kits for DNA purification, however none maximize all four considerations. METHODOLOGY/PRINCIPAL FINDINGS: We now describe a fast, efficient and economic in-house protocol for plasmid preparation using glass syringe filters. Plasmid yield and quality as determined by enzyme digestion and transfection efficiency were equivalent to the expensive commercial kits. Importantly, the time required for purification was much less than that required using a commercial kit. CONCLUSIONS/SIGNIFICANCE: This method provides DNA yield and quality similar to that obtained with commercial kits, but is more rapid and less costly.

  2. A Comparison of Protein Stability in Prefillable Syringes Made of Glass and Plastic.

    Science.gov (United States)

    Waxman, Lloyd; Vilivalam, Vinod D

    2017-01-01

    The development of protein therapeutics requires stabilization of these labile molecules during shipment and storage. Biologics, particularly monoclonal antibodies, are frequently packaged at high concentration in prefillable syringes traditionally made of glass. However, some biologics are unstable in glass due to sensitivity to silicone oil, tungsten, glue, or metal ions. Syringes made from the plastic cyclic olefin polymer, Daikyo Crystal Zenith® (CZ), with a Flurotec-laminated piston, have none of these issues. This study compared the stability of several proteins including biotherapeutics when stored up to 14 months at 5 °C and 25 °C in prefillable siliconized syringes made of glass or silicone oil-free CZ syringes, and when subjected to mild agitation by end-over-end rotation at room temperature. At each time point, proteins were analyzed by several techniques including turbidity, size exclusion high-performance liquid chromatography, reversed phase high-performance liquid chromatography, ion-exchange chromatography, electrophoresis, and light scattering to monitor changes in aggregation and degradation. The results show that proteins have comparable stability when stored in glass syringes or in syringes made of CZ sterilized by E-beam or autoclave. In addition, proteins stressed by agitation were generally more stable and aggregated less in syringes made of CZ than in ones made of glass. LAY ABSTRACT: Biotherapeutic protein drugs such as monoclonal antibodies are frequently packaged at high concentration in prefillable syringes, which allows the drug to be directly administered by the patient or caregiver. Protein drugs, or biologics, can be unstable, and may aggregate, particularly when shaken. These aggregates can be immunogenic, stimulating the body's immune system to produce antibodies that can reduce the drug's efficacy. Although prefillable syringes are traditionally made of glass, some biologics are unstable in glass syringes due to the presence of

  3. Evaluation of clot formation in blood-contrast agent mixture: experimental study on ionic/nonionic contrast agents and plastic/ glass syringes

    International Nuclear Information System (INIS)

    Shim, Hyung Jin; Lee, Jong Beum; Lee, Yong Chul; Lee, Kwan Seh; Kim, Kun Sang

    1991-01-01

    Recent introduction of low-osmolar nonionic contrast agents has allowed the performance of angiography with certain advantages such as reduced pain, reduced osmotic load and other potential advantages, over high osmolar ionic contrast agents. But the potential thrombogenic risk of nonionic contrast agent has been debate because of their weak anticoagulation effect. Several reports have recently documented the formation of thrombi in catheters and syringes containing nonionic contrast agent, and thromboembolic episodes have been noted during angiographic procedures. We have also been experienced blood clotting within blood mixed contrast agent syringe during angiography. Thus, we have studied with blood mixed ionic (Diatrizoate, Ioglicate) agents and nonionic (Iopamidol, Iopromide) agents, that used usually in our hospital, and saline in plastic and glass syringes. Each syringes were checked the clot formation on 10,30,60,90 minutes. Total 340 samples were obtained from 8 adults before angiography. Our data showed that nonionic contrast agents had significantly lesser anticoagulation effect than ionic contrast agents (ρ < 0.0001) on Chi-square test), both in plastic and glass syringes. And formation of clotting in glass syringes were significantly greater than that in plastic syringes (ρ < 0.0001). Thus meticulous technique is required to prevent thrombosis during angiographic procedure using nonionic contrast agents

  4. Physical stability of 20% lipid injectable emulsions via simulated syringe infusion: effects of glass vs plastic product packaging.

    Science.gov (United States)

    Driscoll, David F; Ling, Pei-Ra; Bistrian, Bruce R

    2007-01-01

    The United States Pharmacopeia (USP) has proposed large-globule-size limits to ensure the physical stability of lipid injectable emulsions, expressed as the percent fat >5 microm, or PFAT(5), not exceeding 0.05%. Visibly obvious phase separation as free oil has been shown to occur in some samples if PFAT(5) is >0.4%. We recently found that lipids, newly packaged in plastic (P), exceed the proposed USP limits and seem to produce less stable total nutrient admixtures compared with those made from conventional glass (G), which do meet proposed USP standards. We tested the possible stability differences between 20% lipid injectable emulsions in either P or G in a simulated neonatal syringe infusion study. Eighteen individual syringes were prepared from each 20% lipid injectable emulsion product (n = 36) and attached to a syringe pump set at an infusion rate of 0.5 mL/hour. The starting PFAT(5) levels were measured at time 0 and after 24 hours of infusion, using a laser-based light obscuration technique as described by the USP Chapter . The data were assessed by a 2-way analysis of variance (ANOVA) with Container (G vs P) and Time as the independent variables and PFAT as the dependent variable. At time 0, the starting PFAT(5) level for lipids packaged in G was 0.006% +/- 0.001% vs 0.162% +/- 0.026% for P, whereas at the end of the infusion they were 0.013% +/- 0.003% and 0.328% +/- 0.046%, respectively. Significant differences were noted overall between groups for Container, Time, and Container-Time interaction (all p emulsions packaged in newly introduced plastic containers exceed the proposed USP PFAT(5) limits and subsequently become significantly less stable during a simulated syringe-based infusion. Although modest growth (p = NS) in large-diameter fat globules was observed for the glass-based lipids, they remained within proposed USP globule size limits throughout the study. Glass-based lipids seem to be a more stable dosage form and potentially a safer way to

  5. Assessment of crushed-recycled glass as filter media for drinking water treatment

    International Nuclear Information System (INIS)

    Rutledge, S.O.; Fahie, C.; Gagnon, G.A.

    2002-01-01

    The objective of this project was to evaluate the performance of a pressure filter utilizing crushed glass as the filter media. The performance of the crushed glass filter was compared to that of a sand filter. The research was conducted in Orangedale, Nova Scotia, which is a small community of with a population of approximately 500. Orangedale is located on the south shore of Bras d'Or Lakes and feeds into Miller Pond, which serves as the source the of drinking water. The Orangedale treatment plant produces an average daily flow of 35 m3/d (6.4-gpm). The treatment plant consists of coagulation (sodium aluminate and polyaluminum chloride), flocculation, dissolved air flotation (DAF), disinfection with sodium hypochlorite and dual-media filtration with anthracite and sand. In general, the particle removal capabilities of the crushed glass filter were slightly poorer than that of a sand filter, as quantified in a field application in the community of Orangedale, Nova Scotia. It was found that the crushed glass used in this project had a higher angularity and slightly higher uniformity coefficient. During initial start-up the performance of the crushed glass filter was more variable and appeared to improve as the glass began to wear. After six-months of use the crushed glass filter was able to produce a very consistent filter effluent that was only slightly greater than the silica sand filter. After six-months of use, the sand filter achieved a 1.6 log-removal of particles with diameters greater than 2 μm; whereas the crushed glass filter achieved a 1.4 log removal for the similar particle size range. The observed removal performance was particularly encouraging given that the sand used had properties that were consistent with the standards set by the American Water Works Association. The crushed glass filter media was initially sieved and washed, but had no other pre-treatment preparation. Thus the application of crushed glass shows considerable promise as filter

  6. Syringe calibration factors and volume correction factors for the NPL secondary standard radionuclide calibrator

    CERN Document Server

    Tyler, D K

    2002-01-01

    The activity assay of a radiopharmaceutical administration to a patient is normally achieved via the use of a radionuclide calibrator. Because of the different geometries and elemental compositions between plastic syringes and glass vials, the calibration factors for syringes may well be significantly different from those for the glass containers. The magnitude of these differences depends on the energies of the emitted photons. For some radionuclides variations have been observed of 70 %, it is therefore important to recalibrate for syringes or use syringe calibration factors. Calibration factors and volume correction factors have been derived for the NPL secondary standard radionuclide calibrator, for a variety of commonly used syringes and needles, for the most commonly used medical radionuclide.

  7. Survey of life-cycle costs of glass-paper HEPA filters

    International Nuclear Information System (INIS)

    Moore, P.; Bergman, W.; Gilbert, H.

    1992-08-01

    We have conducted a survey of the major users of glass-paper HEPA filters in the DOE complex to ascertain the life cycle costs of these filters. Purchase price of the filters is only a minor portion of the costs; the major expenditures are incurred during the removal and disposal of contaminated filters. Through personal interviews, site visits and completion of questionnaires, we have determined the costs associated with the use of HEPA filters in the DOE complex. The total approximate life-cycle cost for a standard (2 in. x 2 in. x 1 in.) glass-paper HEPA filter is $3,000 for one considered low-level waste (LLW), $11,780 for transuranic (TRU) and $15,000 for high-level waste (HLW). The weighted-average cost for a standard HEPA filter in the complex is $4,753

  8. Characterization of glass filter micromodels used for polymer EOR flooding experiments

    Energy Technology Data Exchange (ETDEWEB)

    Foedisch, H.; Wegner, J.; Hincapie-Reina, R.; Ganzer, L. [Technische Univ. Clausthal, Clausthal-Zellerfeld (Germany). ITE

    2013-08-01

    This work is conducted as part of the research project DGMK 746 - ''Experimental and Numerical Analysis of Polymer Flooding Processes Using Micromodels - From Pore Scale to Continuum Scale''. The industry standard to assess polymer flood performance is through flooding experiments with cores or plugs. A complement to flooding experiments in cores is represented by micromodels such as glass filters, which resemble real porous media through their porous structures. In this way, an almost unlimited number of equivalent samples can be produced. Moreover, compared to cores the micromodels enable visual access to the flooding process enabling a detailed process description. The sintered glass filters used in this work represent one way to make displacement processes inside artificial structures visible. However, challenges exist to transfer the results obtained from models composed of glass to real plugs or rock sections. Therefore, this study focuses on the comparison of glass filter micromodels and real rock samples composed of Bentheimer sandstone. We determine water permeability and oil-water relative permeability endpoints with flooding experiments, compare capillary pressure functions of the glass models obtained from mercury porosimetry analysis with results from Bentheimer sandstone, and characterize the glass filter with respect of connate water saturation using NMR-spectroscopy and porosity obtained from pycnometer measurements. (orig.)

  9. Gas ampoule-syringe

    International Nuclear Information System (INIS)

    Gay, D.D.

    1986-01-01

    This patent describes disposable gas ampoule holding or containing a gas such as a radioactive gas, comprising: (a) a cylindrical glass tube which is adapted to hold the gas; (b) a layer of absorbent material which circumscribes and which contacts cylindrical glass tube (a) which absorbs the gas; (c) a plastic tube, which circumscribes and contacts absorbent material layer (b) and which is externally threaded on each of its end portions; (d) a cap, which is threaded onto a first end of plastic tube (c); (e) a cylindrical block, which is positioned in the first end of cylindrical glass tube (a) adjacent to cap (d), which contacts cylindrical glass tube (a), which is composed of a foamed material and which is impregnated with a gas adsorbent material; (f) a cylindrical plunger tip, which is located in the first end of cylindrical glass tube (a) in a gas-tight manner adjacent to cylindrical block (e); (g) an end stopper, which has a central cylindrical shaft that is positioned in the second end of cylindrical glass tube (a); and (h) a cap, which is threaded onto the second end of plastic tube (e). A combination of the disposable gas ampoule and syringe adapted to operably interface with the gas ampoule is also described

  10. Consumer perception of risk associated with filters contaminated with glass fibers.

    Science.gov (United States)

    Cummings, K M; Hastrup, J L; Swedrock, T; Hyland, A; Perla, J; Pauly, J L

    2000-09-01

    The filters in Eclipse, a new cigarette-like smoking article marketed by R. J. Reynolds Tobacco Company, are contaminated with glass fibers, fragments, and particles. Reported herein are the results of a study in which consumers were questioned about their opinions as to whether exposure to glass fibers in such a filter poses an added health risk beyond that from smoking and whether the manufacturer has an obligation to inform consumers about the glass contamination problem. The study queried 137 adults who were interviewed while waiting at a Division of Motor Vehicles office in Erie County, New York in 1997. All but one person expressed the view that the presence of glass fibers on the filters poses an added health risk beyond that associated with exposure to tobacco smoke alone. Nearly all expressed the position that the cigarette manufacturer has a duty to inform the public about the potential for glass exposure.

  11. Electret filter collects more exhaled albumin than glass condenser

    Science.gov (United States)

    Jia, Ziru; Liu, Hongying; Li, Wang; Xie, Dandan; Cheng, Ke; Pi, Xitian

    2018-01-01

    Abstract In recent years, noninvasive diagnosis based on biomarkers in exhaled breath has been extensively studied. The procedure of biomarker collection is a key step. However, the traditional condenser method has low efficacy in collecting nonvolatile compounds especially the protein biomarkers in breath. To solve this deficiency, here we propose an electret filter method. Exhaled breath of 6 volunteers was collected with a glass condenser and an electret filter. The amount of albumin was analyzed. Furthermore, the difference of exhaled albumin between smokers and nonsmokers was evaluated. The electret filter method collected more albumin than the glass condenser method at the same breath volume level (P albumin than nonsmokers were also observed (P albumin than nonsmokers. PMID:29384875

  12. Microwave-assisted extraction of metal elements from glass fibrous filters for aerosol sampling

    International Nuclear Information System (INIS)

    Li Dong-Mei; Zhang Li-Xing; Wang Xu-Hui; Liu Long-Bo

    2003-01-01

    Atmospheric aerosols are generally collected on filters according to the International Monitoring System (IMS) designed in the Comprehensive Nuclear-Test-Ban Treaty (CTBT). More information could be revealed when the filter sample is pretreated rather than measured directly by γ-ray spectrometer. Microwave-assisted extraction (MAE) is a suitable method that gives higher recoveries of elements from glass fibrous filters under different conditions. The results indicate that the MAE is a highly efficient and robust method for the treatment of glass fibrous filter samples. The recoveries of potential fission products from glass fibrous filter samples by microwave-assisted extraction meet the efficiency of the extraction by both aqua regia and 2% HCl. (author)

  13. Development and testing the modular fireproof fine filters on the basis of glass paper

    International Nuclear Information System (INIS)

    Rovnyj, S.I.; Glagolenko, Yu.V.; Pyatin, N.P.; Tranchuk, O.A.; Maksimov, V.E.; Afanas'eva, E.V.

    2006-01-01

    Paper describes a procedure to fabricate modified module glass paper fine filters to trap radioactive substances (14 models). The mentioned filters are made of a glass paper ensuring their fire-resistance. Paper describes the procedure of service life tests of the designed filters and the efficient procedure to extract valuable components from the spent filters [ru

  14. Stability of Hydromorphone-Ketamine Solutions in Glass Bottles, Plastic Syringes, and IV Bags for Pediatric Use.

    Science.gov (United States)

    Ensom, Mary H H; Decarie, Diane; Leung, Karen; Montgomery, Carolyne

    2009-03-01

    To evaluate the stability of mixtures of hydromorphone and ketamine in 0.9% sodium chloride (normal saline [NS]) after storage for up to 7 days at room temperature (25°C). The stability of 3 standard mixtures of hydromorphone and ketamine (hydromorphone 0.2 mg/mL + ketamine 0.2 mg/mL, hydromorphone 0.2 mg/mL + ketamine 0.6 mg/mL, and hydromorphone 0.2 mg/mL + ketamine 1.0 mg/mL) in NS was studied. Portions of each mixture were transferred to 3 brown glass bottles (100 mL), 3 plastic syringes (50 mL), and 3 IV bags (50 mL), which were then stored at room temperature (25°C). Physical characteristics, including pH, colour, and precipitation, were evaluated daily. Three 1.5-mL samples were collected from each bottle, syringe, and IV bag at baseline, at 24, 48, and 72 hours, and on day 7. Samples were analyzed in triplicate by a stability-indicating high-performance liquid chromatography method. Solutions were considered stable if they maintained 90% of the initial concentration of each drug. Samples from syringes and IV bags were subjected to standard sterility testing by incubation for 5 days in an enriched culture media. No notable changes in pH or colour were observed, and no precipitation occurred in any of the solutions. All formulations maintained more than 90% of the initial concentration of each drug on day 7. No bacterial growth was observed in any of the samples tested. Mixtures of hydromorphone and ketamine were stable for up 7 days at 25°C, and the sterility of the preparations was maintained. Because stability alone does not guarantee efficacy, it is recommended that clinical studies be conducted to evaluate the pharmacokinetics and pharmacodynamics of these formulations.

  15. Evidence for and implications of self-background of radon dosimeters with glass-fiber filters

    International Nuclear Information System (INIS)

    Put, L.W.; Lembrechts, J.; Graaf, E.R. van der; Stoop, P.

    2000-01-01

    The first national radon survey in the Netherlands was conducted in 1984 with passive radon dosimeters that contain glass-fiber diffusion filters. During the last few years, measurements of outdoor-radon concentrations and information in the literature suggested that these dosimeters may give falsely elevated readings. A systematic contribution would be present due to alpha particles from natural radionuclides in the glass-fiber filter producing tracks on the track-etch foil. In the framework of the quality assurance of their laboratories, the origin of this offset was systematically assessed by means of measurements of alpha and gamma radiation from the glass-fiber filters and by intercomparisons between different types of detectors at low radon concentrations. It was found that alpha particles from the decay of 214 Po in the glass-fiber filter are the main cause of the extra tracks (only 12% originates from decay of 212 Po), leading, for this type of filter, to an offset in concentration of approximately 8 Bq m -3 . The implications of this offset are discussed

  16. A Method for Cobalt and Cesium Leaching from Glass Fiber in HEPA Filter

    International Nuclear Information System (INIS)

    Kim, Gye Nam; Lee, Suk Chol; Yang, Hee Chul; Yoon, In Ho; Choi, Wang Kyu; Moon, Jei Kwon

    2011-01-01

    A great amount of radioactive waste has been generated during the operation of nuclear facilities. Recently, the storage space of a radioactive waste storage facility in the Korea Atomic Energy Research Institute (KAERI) was almost saturated with many radioactive wastes. So, the present is a point of time that a volume reduction of the wastes in a radioactive waste storage facility needs. There are spent HEPA filter wastes of about 2,226 sets in the radioactive waste storage facility in KAERI. All these spent filter wastes have been stored in accordance with their original form without any treatment. Up to now a compression treatment of these spent HEPA filters has been carried out to repack the compressed spent HEPA filters into a 200 liter drum for their volume reduction. Frame and separator are contaminated with a low concentration of nuclide, while the glass fiber is contaminated with a high concentration of nuclide. So, for the disposal of the glass filter to the environment, the glass fiber should be leached to lower its radioactive concentration first and then must be stabilized by solidification and so on. Therefore, it is necessary to develop a leaching process of glass fiber in a HEPA filter. Leaching is a separation technology, which is often used to remove a metal or a nuclide from a solid mixture with the help of a liquid solvent

  17. Plutonium recovery from spent glass fiber paper fine air filter

    International Nuclear Information System (INIS)

    Rovnyj, S.I.; Guzhavin, V.I.; Pyatin, N.P.; Evlanov, D.S.

    2002-01-01

    Investigations into the realizing technology of plutonium recovery from waste glass paper filters of fine purification were conducted. Two process schemes involving the nitro-fluoro-acid treatment of glass paper in the mixture of nitric and hydrofluoric acids and the previous alkali treatment of glass paper with the following nitro-fluoro-acid leaching of plutonium from pulp by the mixture of nitric and hydrofluoric acids were developed. Alkali, nitrate solutions and insoluble precipitants were analyzed for plutonium content [ru

  18. [Trial manufacture of a plunger shield for a disposable plastic syringe].

    Science.gov (United States)

    Murakami, Shigeki; Emoto, Takashi; Mori, Hiroshige; Fujita, Katsuhisa; Kubo, Naoki

    2008-08-20

    A syringe-type radiopharmaceutical being supplied by a manufacturer has a syringe shield and a plunger shield, whereas an in-hospital labeling radiopharmaceutical is administered by a disposable plastic syringe without the plunger shield. In cooperation with Nihon Medi-Physics Co. Ltd., we have produced a new experimental plunger shield for the disposable plastic syringe. In order to evaluate this shielding effect, we compared the leaked radiation doses of our plunger shield with those of the syringe-type radiopharmaceutical (Medi shield type). Our plunger shield has a lead plate of 21 mm in diameter and 3 mm thick. This shield is equipped with the plunger-end of a disposal plastic syringe. We sealed 99mTc solution into a plastic syringe (Terumo Co.) of 5 ml with our plunger shield and Medi shield type of 2 ml. We measured leaked radiation doses around syringes using fluorescent glass dosimeters (Dose Ace). The number of measure points was 18. The measured doses were converted to 70 microm dose equivalent at 740 MBq of radioactivity. The results of our plunger shield and the Medi shield type were as follows: 4-13 microSv/h and 3-14 microSv/h at shielding areas, 3-545 microSv/h and 6-97 microSv/h at non-shielding areas, 42-116 microSv/h and 88-165 microSv/h in the vicinity of the syringe shield, and 1071 microSv/h and 1243 microSv/h at the front of the needle. For dose rates of shielding areas around the syringe, the shielding effects were approximately the same as those of the Medi shield type. In conclusion, our plunger shield may be useful for reducing finger exposure during the injection of an in-hospital labeled radiopharmaceutical.

  19. Syringe sociology.

    Science.gov (United States)

    Vitellone, Nicole

    2015-06-01

    In this article I consider the impact of social epistemologies for understanding the object of the syringe. My aim is to examine the process through which the syringe transforms from an injecting device to a tool of social and political inquiry. Paying particular attention to the uses of Foucault, Becker, Bourdieu, Freud and Latour in empirical studies of injecting heroin use, I examine the sociology of the syringe through the lens of habit and habitus, discourse and deviance, mourning and melancholia, attachment and agencement. In pursuing the theory behind the object my goal is to address a sociological object in the making. In so doing I show how the syringe has been significant for social research, social theory, and sociology. It is the difference the object makes that this article seeks to describe. In tracing the epistemology of the syringe I show how the object is important not just for knowledge of addiction but sociology itself. © London School of Economics and Political Science 2015.

  20. Glass wool filters for concentrating waterborne viruses and agricultural zoonotic pathogens

    Science.gov (United States)

    Millen, Hana T.; Gonnering, Jordan C.; Berg, Ryan K.; Spencer, Susan K.; Jokela, William E.; Pearce, John M.; Borchardt, Jackson S.; Borchardt, Mark A.

    2012-01-01

    The key first step in evaluating pathogen levels in suspected contaminated water is concentration. Concentration methods tend to be specific for a particular pathogen group, for example US Environmental Protection Agency Method 1623 for Giardia and Cryptosporidium1, which means multiple methods are required if the sampling program is targeting more than one pathogen group. Another drawback of current methods is the equipment can be complicated and expensive, for example the VIRADEL method with the 1MDS cartridge filter for concentrating viruses2. In this article we describe how to construct glass wool filters for concentrating waterborne pathogens. After filter elution, the concentrate is amenable to a second concentration step, such as centrifugation, followed by pathogen detection and enumeration by cultural or molecular methods. The filters have several advantages. Construction is easy and the filters can be built to any size for meeting specific sampling requirements. The filter parts are inexpensive, making it possible to collect a large number of samples without severely impacting a project budget. Large sample volumes (100s to 1,000s L) can be concentrated depending on the rate of clogging from sample turbidity. The filters are highly portable and with minimal equipment, such as a pump and flow meter, they can be implemented in the field for sampling finished drinking water, surface water, groundwater, and agricultural runoff. Lastly, glass wool filtration is effective for concentrating a variety of pathogen types so only one method is necessary. Here we report on filter effectiveness in concentrating waterborne human enterovirus, Salmonella enterica, Cryptosporidium parvum, and avian influenza virus.

  1. Direct preparation of a graphene oxide modified monolith in a glass syringe as a solid-phase extraction cartridge for the extraction of quaternary ammonium alkaloids from Chinese patent medicine.

    Science.gov (United States)

    Liang, Xiaojing; Wang, Licheng; Wang, Shuai; Li, Yijing; Guo, Yong

    2017-11-01

    Packed cartridges have been widely used in solid-phase extraction. However, there are still some drawbacks, such as they are blocked easily and the method is time-consuming. In view of the advantages of monoliths, a monolithic extraction material has been directly synthesized in a glass syringe without any gap between the monolith and syringe inner wall. The monolithic syringe was modified with graphene oxide by loading graphene oxide dispersion onto it. The content of graphene oxide and the surface topography of the monolith have been evaluated by elemental analysis and scanning electron microscopy, respectively, which confirmed the successful modification. This prepared graphene oxide-modified monolithic syringe was directly used as a traditional solid-phase extraction cartridge. As expected, it shows good permeability and excellent capability for the extraction of quaternary ammonium alkaloids. The sample loading velocity (1-6 mL/min) does not affect the recovery. Under the optimal conditions, good linearities (R = 0.9992-0.9998) were obtained for five quaternary ammonium alkaloids, and the limits of detection and quantification were 0.5-1 and 1-2 μg/L, respectively. The proposed method was successfully applied for the analysis of quaternary ammonium alkaloids in Chinese patent medicine. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Radiological results for samples collected on paired glass- and cellulose-fiber filters at the Sandia complex, Tonopah Test Range, Nevada

    International Nuclear Information System (INIS)

    Mizell, Steve A.; Shadel, Craig A.

    2016-01-01

    Airborne particulates are collected at U.S. Department of Energy sites that exhibit radiological contamination on the soil surface to help assess the potential for wind to transport radionuclides from the contamination sites. Collecting these samples was originally accomplished by drawing air through a cellulose-fiber filter. These filters were replaced with glass-fiber filters in March 2011. Airborne particulates were collected side by side on the two filter materials between May 2013 and May 2014. Comparisons of the sample mass and the radioactivity determinations for the side-by-side samples were undertaken to determine if the change in the filter medium produced significant results. The differences in the results obtained using the two filter types were assessed visually by evaluating the time series and correlation plots and statistically by conducting a nonparametric matched-pair sign test. Generally, the glass-fiber filters collect larger samples of particulates and produce higher radioactivity values for the gross alpha, gross beta, and gamma spectroscopy analyses. However, the correlation between the radioanalytical results for the glass-fiber filters and the cellulose-fiber filters was not strong enough to generate a linear regression function to estimate the glass-fiber filter sample results from the cellulose-fiber filter sample results.

  3. Adrenaline in cardiac arrest: Prefilled syringes are faster.

    Science.gov (United States)

    Helm, Claire; Gillett, Mark

    2015-08-01

    Standard ampoules and prefilled syringes of adrenaline are widely available in Australasian EDs for use in cardiac arrest. We hypothesise that prefilled syringes can be administered more rapidly and accurately when compared with the two available standard ampoules. This is a triple arm superiority study comparing the time to i.v. administration and accuracy of dosing of three currently available preparations of adrenaline. In their standard packaging, prefilled syringes were on average more than 12 s faster to administer than the 1 mL 1:1000 ampoules and more than 16 s faster than the 10 mL 1:10,000 ampoules (P adrenaline utilising a Minijet (CSL Limited, Parkville, Victoria, Australia) is faster than using adrenaline in glass ampoules presented in their plastic packaging. Removing the plastic packaging from the 1 mL (1 mg) ampoule might result in more rapid administration similar to the Minijet. Resuscitation personnel requiring rapid access to adrenaline should consider storing it as either Minijets or ampoules devoid of packaging. These results might be extrapolatable to other clinical scenarios, including pre-hospital and anaesthesia, where other drugs are required for rapid use. © 2015 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  4. Do your syringes count?

    International Nuclear Information System (INIS)

    Brewster, K.

    2002-01-01

    Full text: This study was designed to investigate anecdotal evidence that residual Sestamibi (MIBI) activity vaned in certain situations. For rest studies different brands of syringes were tested to see if the residuals varied. The period of time MIBI doses remained in the syringe between dispensing and injection was also considered as a possible source of increased residual counts. Stress Mibi syringe residual activities were measured to assess if the method of stress test affected residual activity. MIBI was reconstituted using 13 Gbq of Technetium in 3mls of normal saline then boiled for 10 minutes. Doses were dispensed according to department protocol and injected via cannula. Residual syringes were collected for three syringe types. In each case the barrel and plunger were measured separately. As the syringe is flushed during the exercise stress test and not the pharmacological stress test the chosen method was recorded. No relationship was demonstrated between the time MIBI remained in a syringe prior to injection and residual activity. Residual activity was not affected by method of stress test used. Actual injected activity can be calculated if the amount of activity remaining in the syringe post injection is known. Imaging time can be adjusted for residual activity to optimise count statistics. Preliminary results in this study indicate there is no difference in residual activity between syringe brands.Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  5. Comparative evaluation of endodontic pressure syringe, insulin syringe, jiffy tube, and local anesthetic syringe in obturation of primary teeth: An in vitro study.

    Science.gov (United States)

    Hiremath, Mallayya C; Srivastava, Pooja

    2016-01-01

    The purpose of this in vitro study was to compare four methods of root canal obturation in primary teeth using conventional radiography. A total of 96 root canals of primary molars were prepared and obturated with zinc oxide eugenol. Obturation methods compared were endodontic pressure syringe, insulin syringe, jiffy tube, and local anesthetic syringe. The root canal obturations were evaluated by conventional radiography for the length of obturation and presence of voids. The obtained data were analyzed using Chi-square test. The results showed significant differences between the four groups for the length of obturation (P tube showed the poor results (37.5% optimal fillings) for the length of obturation. The insulin syringe (79.2% optimal fillings) and local anesthetic syringe (66.7% optimal fillings) showed acceptable results for the length of root canal obturation. However, minor voids were present in all the four techniques used. Endodontic pressure syringe produced the best results in terms of length of obturation and controlling paste extrusion from the apical foramen. However, insulin syringe and local anesthetic syringe can be used as effective alternative methods.

  6. Design and engineering of IZO/Ag/glass solar filters for low-emissivity window performance

    Science.gov (United States)

    Hernandez-Mainet, Luis C.; Aguilar, Miguel A.; Tamargo, Maria C.; Falcony, Ciro

    2017-10-01

    The electricity consumption in houses and commercial buildings generates about 18% of greenhouse gas emission. A critical issue of building energy consumption is heat and cooling loss through the window. Low-emissivity windows control thermal radiation through glass without decreasing the intensity of visible light. They are made up of optical filter coatings grown on a flat glass surface. Solar filters based on Ag/IZO multilayer films are grown and simulated on glass substrate. The targeted structure designs are grown by a sputtering system and characterized by scanning electron microscopy and x-ray diffraction techniques. To accurately simulate transmission spectrum, silver (Ag) and IZO optical constants were estimated by fitting ellipsometric data at different thicknesses. Transmission spectrum shows a good agreement among experiment and simulation. In addition, optical constant curves strongly show layer thickness dependence in both materials. In particular, the ultrathin Ag layer displays a percolation threshold in the vicinity of 15 nm, which leads to surface plasmon resonance with absorption at about 450 nm. These types of optical filter coatings would have potential applications as low-emission windows.

  7. Characterization of BG28 and KG3 filter glass for Drive Diagnostic Attenuators

    Energy Technology Data Exchange (ETDEWEB)

    Page, R H; Weiland, T; Folta, J

    2007-11-30

    BG28 and KG3 filter glasses were tested for use as attenuators in the NIF drive diagnostic (DrD) systems. Tests were performed in the Optical Sciences Laser facility with a 351 nm, 2-step, 3-nsec pulse at fluences ranging up to {approx} 1 J/cm{sup 2}. Single-shot measurements showed no solarization when the samples were allowed to relax for a week after exposure. KG3 filters exhibited no luminescence and no transient pulse distortion. BG28 filters luminesced appreciably and imposed a 'droop' (similar to 'square-pulse distortion') on the signals. The droop parameter is estimated at 0.50 {+-} 0.11 cm{sup 2}/J. Droop is explained in terms of known copper-doped-glass spectroscopy and kinetics (buildup of triplet-state populations, with excited-state absorption). Simulation of the distortion ({approx}1.6%) expected on a 1.8 MJ Haan pulse led to a minor redesign of the Drive Diagnostic with reduced fluence on the BG28 filters to reduce the droop distortion to 0.5%.

  8. [The effect of colored syringes and a colored sheet on the incidence of syringe swaps during anesthetic management].

    Science.gov (United States)

    Hirabayashi, Yoshihiro; Kawakami, Takayuki; Suzuki, Hideo; Igarashi, Takashi; Saitoh, Kazuhiko; Seo, Norimasa

    2005-09-01

    Syringe swap is an important problem in anesthetic care, causing harm to patients. We examined the effect of colored syringe and a colored sheet on the incidence of syringe swaps during anesthetic management. We determined the color code. The blue-syringe contains local anesthetics; yellow-syringe, sympathomimetic drugs; and white-syringe with a red label fixed opposite the scale, muscle relaxants. The colored sheet displays the photographs of the syringe with drug name, dose and volume. The colored syringe and colored sheet were supplied for use from February 2004. We compared the incidence of syringe swaps during the period from February 2004 to January 2005 with that from February 2003 to January 2004. Although five syringe swaps were recorded from February 2003 to January 2004, in 5901 procedures, we encountered no syringe swaps from February 2004 to January 2005, in 6078 procedures. The colored syringe and colored sheet significantly decreased the incidence of syringe swaps during anesthetic management (P sheet together with colored syringes can prevent syringe swaps during anesthesia.

  9. The association of syringe type and syringe cleaning with HCV infection among IDUs in Budapest, Hungary

    Science.gov (United States)

    Gyarmathy, V. Anna; Neaigus, Alan; Mitchell, Mary M.; Ujhelyi, Eszter

    2008-01-01

    We assessed whether syringe type, syringe cleaning and distributive syringe sharing were associated with self-reported and laboratory confirmed HCV infection among Hungarian IDUs. Injecting drug users (N=215) were recruited from non-treatment settings in Budapest, Hungary between October 2005 and December 2006. Multivariate logistic regression models identified correlates of self-report of being HCV infected and testing positive for HCV. While 37% tested positive for HCV, 14% of the total (39% of those who tested positive) self-reported being HCV infected. Using any two piece syringes was significantly associated with self-reported HCV infection, while distributive syringe sharing was not associated with self-report of being HCV infected. Engaging in receptive sharing of only one-piece syringes but always cleaning before reuse was not associated with testing HCV positive, while any receptive sharing of only one-piece syringes and not always cleaning before reuse was significantly associated with testing HCV positive. Sharing cookers and squirting drugs from one syringe into another syringe were not associated with testing HCV positive. The high percent of those HCV infected who did not know they were infected highlights the need to provide better access to confidential testing and counseling services. Counseling should emphasize secondary prevention of HCV among HCV infected IDUs. Our findings also indicate that syringe type and syringe cleaning practices may play a role in HCV transmission. Ethnographic research should identify the reasons why IDUs may use two-piece syringes and suggest means to reduce their use. Thorough cleaning of one-piece syringes when sterile syringes are unavailable may be an efficient way to reduce the risk of HCV infection. PMID:19058925

  10. In-syringe-stirring: A novel approach for magnetic stirring-assisted dispersive liquid–liquid microextraction

    International Nuclear Information System (INIS)

    Horstkotte, Burkhard; Suárez, Ruth; Solich, Petr; Cerdà, Víctor

    2013-01-01

    Graphical abstract: -- Highlights: •We propose a new automatic magnetic stirring assisted dispersive liquid–liquid microextraction. •It allows the extraction of aluminum from seawater and freshwater samples within less than 4 min. •The method was applicable to the natural samples. -- Abstract: For the first time, the use of a magnetic stirrer within the syringe of an automated syringe pump and the resulting possible analytical applications are described. A simple instrumentation following roughly the one from sequential injection analyzer systems is used in combination with an adaptor, which is placed onto the barrel of a glass syringe. Swirling around the longitudinal axis of the syringe and holding two strong neodymium magnets, it causes a rotating magnetic field and serves as driver for a magnetic stirring bar placed inside of the syringe. In a first study it was shown that this approach leads to a sealed but also automatically adaptable reaction vessel, the syringe, in which rapid and homogeneous mixing of sample with the required reagents within short time can be carried out. In a second study in-a-syringe magnetic stirring-assisted dispersive liquid–liquid microextraction (MSA-DLLME) was demonstrated by the application of the analyzer system to fluorimetric determination of aluminum in seawater samples using lumogallion. A linear working range up to 1.1 μmol L −1 and a limit of detection of 6.1 nmol L −1 were found. An average recovery of 106.0% was achieved for coastal seawaters with a reproducibility of 4.4%. The procedure lasted 210 s including syringe cleaning and only 150 μL of hexanol and 4.1 mL of sample were required

  11. Removing Pathogens Using Nano-Ceramic-Fiber Filters

    Science.gov (United States)

    Tepper, Frederick; Kaledin, Leonid

    2005-01-01

    A nano-aluminum-oxide fiber of only 2 nanometers in diameter was used to develop a ceramic-fiber filter. The fibers are electropositive and, when formulated into a filter material (NanoCeram(TradeMark)), would attract electro-negative particles such as bacteria and viruses. The ability to detect and then remove viruses as well as bacteria is of concern in space cabins since they may be carried onboard by space crews. Moreover, an improved filter was desired that would polish the effluent from condensed moisture and wastewater, producing potable drinking water. A laboratory- size filter was developed that was capable of removing greater than 99.9999 percent of bacteria and virus. Such a removal was achieved at flow rates hundreds of times greater than those through ultraporous membranes that remove particles by sieving. Because the pore size of the new filter was rather large as compared to ultraporous membranes, it was found to be more resistant to clogging. Additionally, a full-size cartridge is being developed that is capable of serving a full space crew. During this ongoing effort, research demonstrated that the filter media was a very efficient adsorbent for DNA (deoxyribonucleic acid), RNA (ribonucleic acid), and endotoxins. Since the adsorption is based on the charge of the macromolecules, there is also a potential for separating proteins and other particulates on the basis of their charge differences. The separation of specific proteins is a major new thrust of biotechnology. The principal application of NanoCeram filters is based on their ability to remove viruses from water. The removal of more than 99.9999 percent of viruses was achieved by a NanoCeram polishing filter added to the effluent of an existing filtration device. NanoCeram is commercially available in laboratory-size filter discs and in the form of a syringe filter. The unique characteristic of the filter can be demonstrated by its ability to remove particulate dyes such as Metanyl yellow. Its

  12. Application of Cu{sub 2}O-doped phosphate glasses for bandpass filter

    Energy Technology Data Exchange (ETDEWEB)

    Elhaes, H. [Physics Department, Faculty of Women for Arts, Science and Education, Ain Shams University, 11757 Cairo (Egypt); Attallah, M., E-mail: m_atallah94@yahoo.com [Basic Science Department, Higher Technological Institute, 10th of Ramadan City (Egypt); Elbashar, Y.; El-Okr, M. [Physics Department, Faculty of Science, Al Azhar University, Cairo (Egypt); Ibrahim, M. [Spectroscopy Department, National Research Centre, 12311 Dokki, Cairo (Egypt)

    2014-09-15

    Phosphate glasses doped with copper ions having general composition 42P{sub 2}O{sub 5}–39ZnO–(18−x) Na{sub 2}O–1CaO–xCu{sub 2}O [x=2, 4, 6, 8, 10 mol%] were prepared using a conventional melt-quench technique. Physical and chemical properties of the glasses were investigated using X-ray diffraction technique and UV–visible optical absorption. The density was measured by Archimedes' method, and molar volume (V{sub M}) was calculated. It is found that density and molar volume show opposite trend by increasing Cu{sub 2}O content. Absorbance and transmittance at the normal incidence are measured by a spectrophotometer in the spectral range of 190–1100 nm. Analyses of the obtained results were considered in the frame of current theories. Absorption data were used for absorption coefficient, the optical band gap (E{sub opt}), the cutoff in UV and IR bands to the bandpass filter, which confirmed the optical properties of this type of filter. E{sub opt} values for different glass samples are found to decrease with increasing Cu{sub 2}O content.

  13. A study of glasses-type color CGH using a color filter considering reduction of blurring

    Science.gov (United States)

    Iwami, Saki; Sakamoto, Yuji

    2009-02-01

    We have developed a glasses-type color computer generated hologram (CGH) by using a color filter. The proposed glasses consist of two "lenses" made of overlapping holograms and color filters. The holograms, which are calculated to reconstruct images in each primary color, are divided to small areas, which we called cells, and superimposed on one hologram. In the same way, colors of the filter correspond to the hologram cells. We can configure it very simply without a complex optical system, and the configuration yields a small and light weight system suitable for glasses. When the cell is small enough, the colors are mixed and reconstructed color images are observed. In addition, color expression of reconstruction images improves, too. However, using small cells blurrs reconstructed images because of the following reasons: (1) interference between cells because of the correlation with the cells, and (2) reduction of resolution caused by the size of the cell hologram. We are investigating in order to make a hologram that has high resolution reconstructed color images without ghost images. In this paper, we discuss (1) the details of the proposed glasses-type color CGH, (2) appropriate cell size for an eye system, (3) effects of cell shape on the reconstructed images, and (4) a new method to reduce the blurring of the images.

  14. UV Blocking Glass: Low Cost Filters for Visible Light Photocatalytic Assessment

    Directory of Open Access Journals (Sweden)

    Charles W. Dunnill

    2014-01-01

    Full Text Available A number of commercially available art protection products have been compared and assessed for their suitability as UV blocking filters in the application of “visible light” photocatalytic research. Many groups claiming visible light photocatalytic success employ filters to block out stray UV radiation in order to justify that their photocatalysts are indeed visible light photocatalysts and not UV light photocatalysts. These filters come in varying degrees of ability and price and many authors fail to correctly characterise their filters in individual papers. The use of effective filters to prevent both false positive and false negative results is important to maintain scientific rigor and create accurate understanding of the subject. The optimum UV filter would have the highest UV blocking properties (<390 nm and simultaneously the highest visible light transmission (390–750 nm. Single and double layers of each of the glass products were assessed as well as laminate products. The conclusions show an inexpensive and highly effective setup for the conduction of visible light photochemistry that should be incorporated as a standard part in any researcher’s work where the claim of visible light activity is made.

  15. Comparative evaluation of endodontic pressure syringe, insulin syringe, jiffy tube, and local anesthetic syringe in obturation of primary teeth: An in vitro study

    OpenAIRE

    Hiremath, Mallayya C.; Srivastava, Pooja

    2016-01-01

    Purpose: The purpose of this in vitro study was to compare four methods of root canal obturation in primary teeth using conventional radiography. Materials and Methods: A total of 96 root canals of primary molars were prepared and obturated with zinc oxide eugenol. Obturation methods compared were endodontic pressure syringe, insulin syringe, jiffy tube, and local anesthetic syringe. The root canal obturations were evaluated by conventional radiography for the length of obturation and presenc...

  16. Effects of Different Containers on Radioactivity Measurements using a Dose Calibrator with Special Reference to 111In and 123I.

    Science.gov (United States)

    Inoue, Yusuke; Abe, Yutaka; Kikuchi, Kei; Miyatake, Hiroki; Watanabe, Atsushi

    2017-01-01

    Low-energy characteristic x-rays emitted by 111 In and 123 I sources are easily absorbed by the containers of the sources, affecting radioactivity measurements using a dose calibrator. We examined the effects of different containers on the estimated activities. The radioactivities of 111 In, 123 I, 201 Tl, and 99m Tc were measured in containers frequently employed in clinical practice in Japan. The 111 In measurements were performed in the vials A and B of the 111 In-pentetreotide preparation kit and in the plastic syringe. The activities of 123 I-metaiodobenzylguanidine and 201 Tl chloride were measured in the prefilled glass syringes and plastic syringes. The milking vial, vial A, vial B, and plastic syringe were used to assay 99m Tc. For 111 In and 123 I, measurements were performed with and without a copper filter. The filter was inserted into the well of the dose calibrator to absorb low-energy x-rays. The relative estimate was defined as the ratio of the activity estimated with the dose calibrator to the standard activity. The estimated activities varied greatly depending on the container when 111 In and 123 I sources were assayed without the copper filter. The relative estimates of 111 In were 0.908, 1.072, and 1.373 in the vial A, vial B, and plastic syringe, respectively. The relative estimates of 123 I were 1.052 and 1.352 in the glass syringe and plastic syringe, respectively. Use of the copper filter eliminated the container-dependence in 111 In and 123 I measurements. Container-dependence was demonstrated in neither 201 Tl nor 99m Tc measurements. The activities of 111 In and 123 I estimated with a dose calibrator differ greatly among the containers. Accurate estimation may be attained using the container-specific correction factor or using the copper filter.

  17. Extractables and leachables considerations for prefilled syringes.

    Science.gov (United States)

    Jenke, Dennis R

    2014-10-01

    Use of pre-filled syringes as both a packaging and delivery system for pharmaceutical drug products is accelerating. Pre-filled syringes must meet the quality and suitability for use requirements for both systems, including compatibility with the drug product. Relevant incompatibilities between pre-filled syringes and drug products include the safety of syringe-based leachables that accumulate in drug products and the ability of leachables to interact with the drug product's ingredients as such interactions can affect safety, efficacy, stability and physical viability. Relevant suitability considerations for pre-filled syringes are discussed herein and specific examples of suitability for use issues for pre-filled syringes are cited, focusing on extractables associated with pre-filled syringes and leachables derived from such syringes. Aspects considered include the toxicological impact of leachables, their ability to alter the efficacy of drug products and to produce other undesirable outcomes such as aggregation and immunogenic responses. Materials used in pre-filled syringes and the conditions of use minimize the traditional safety risk associated with leachables. However, drug products that use pre-filled syringes are prone to non-traditional interactions such as disruption of protein conformation, leading to potential efficacy, safety and quality issues. In order to qualify pre-filled syringes for use, the traditional approach of measuring extractables and leachables and inferring their effect must be augmented by rigorous compatibility testing. Research into the fundamental relationship between leachables and drug substances will be necessary so the more time- and cost-efficient 'measure and infer' approach can be widely implemented.

  18. Embedded nanomicro syringe on chip for molecular therapy

    Directory of Open Access Journals (Sweden)

    Jalil MA

    2011-11-01

    Full Text Available Muhammad Arif Jalil1, Nathaporn Suwanpayak2,3, Kathawut Kulsirirat3, Saisudawan Suttirak3, Jalil Ali4, Preecha P Yupapin31Ibnu Sina Institute of Fundamental Science Studies, Nanotechnology Research Alliance, Universiti Teknologi Malaysia, Johor Bahru, Malaysia; 2King Mongkut's Institute of Technology Ladkrabang, Chumphon Campus, Chumphon, Thailand; 3Nanoscale Science and Engineering Research Alliance, Advanced Research Center for Photonics, Faculty of Science, King Mongkut's Institute of Technology Ladkrabang, Bangkok, Thailand; 4Institute of Advanced Photonics Science, Nanotechnology Research Alliance, Universiti Teknologi Malaysia, Johor Bahru, MalaysiaBackground: A novel nanomicro syringe system was proposed for drug storage and delivery using a PANDA ring resonator and atomic buffer. A PANDA ring is a modified optical add/drop filter, named after the well known Chinese bear. In principle, the molecule/drug is trapped by the force generated by different combinations of gradient fields and scattering photons within the PANDA ring. A nanomicro needle system can be formed by optical vortices in the liquid core waveguide which can be embedded on a chip, and can be used for long-term treatment. By using intense optical vortices, the required genes/molecules can be trapped and transported dynamically to the intended destinations via the nanomicro syringe, which is available for drug delivery to target tissues, in particular tumors. The advantage of the proposed system is that by confining the treatment area, the effect can be decreased. The use of different optical vortices for therapeutic efficiency is also discussed.Keywords: nanomicro syringe, nanomicro needle, molecular therapy, therapeutic efficiency, cancer

  19. Physicochemical stability of carfilzomib (Kyprolis®) containing solutions in glass vials, ready-to-administer plastic syringes and infusion bags over a 28-day storage period.

    Science.gov (United States)

    Kim, Sun Hee; Krämer, Irene

    2017-01-01

    Centralized aseptic preparation of ready-to-administer carfilzomib containing parenteral solutions in plastic syringes and polyolefine (PO) infusion bags needs profound knowledge about the physicochemical stability in order to determine the beyond-use-date of the preparations. Therefore, the purpose of this study was to determine the physicochemical stability of carfilzomib solution marketed as Kyprolis® powder for solution for infusion. Reconstituted solutions and ready-to-administer preparations of Kyprolis® stored under refrigeration (2-8℃) or at room temperature (25℃) were analyzed at predetermined intervals over a maximum storage period of 28 days. Chemical stability of carfilzomib was planned to be determined with a stability-indicating reversed-phase high-performance liquid chromatography assay. Physicochemical stability was planned to be determined by visual inspection of clarity and color as well as pH measurement. The study results show that reconstituted carfilzomib containing parenteral solutions are stable in glass vials as well as diluted solutions in plastic syringes and PO infusion bags over a period of at least 28 days when stored light protected under refrigeration. When stored at room temperature, reconstituted and diluted carfilzomib solutions are physicochemically stable over 14 days and 10 days, respectively. The physicochemical stability of carfilzomib infusion solutions allows cost-saving pharmacy-based centralized preparation of ready-to-administer preparations.

  20. Safety syringes and anti-needlestick devices in orthopaedic surgery.

    Science.gov (United States)

    Sibbitt, Wilmer L; Band, Philip A; Kettwich, Lawrence G; Sibbitt, Cristina R; Sibbitt, Lori J; Bankhurst, Arthur D

    2011-09-07

    The American Academy of Orthopaedic Surgery (AAOS), The Joint Commission, the Occupational Safety and Health Administration (OSHA), and the Needlestick Safety and Prevention Act encourage the integration of safety-engineered devices to prevent needlestick injuries to health-care workers and patients. We hypothesized that safety syringes and needles could be used in outpatient orthopaedic injection and aspiration procedures. The study investigated the orthopaedic uses and procedural idiosyncrasies of safety-engineered devices, including (1) four safety needles (Eclipse, SafetyGlide, SurGuard, and Magellan), (2) a mechanical safety syringe (RPD), (3) two automatic retractable syringes (Integra, VanishPoint), (4) three manual retractable syringes (Procedur-SF, Baksnap, Invirosnap), and (5) three shielded syringes (Safety-Lok, Monoject, and Digitally Activated Shielded [DAS] Syringe). The devices were first tested ex vivo, and then 1300 devices were used for 425 subjects undergoing outpatient arthrocentesis, intra-articular injections, local anesthesia, aspiration biopsy, and ultrasound-guided procedures. During the clinical observation, there were no accidental needlesticks (0 needlesticks per 1300 devices). Safety needles could be successfully used on a Luer syringe but were limited to ≤1.5 in (≤3.81 cm) in length and the shield could interfere with sonography. The mechanical safety syringes functioned well in all orthopaedic procedures. Automatic retractable syringes were too small for arthrocentesis of the knee, and the plunger blew out and prematurely collapsed with high-pressure injections. The manual retractable syringes and shielded syringes could be used with conventional needles for most orthopaedic procedures. The most effective and reliable safety devices for orthopaedic syringe procedures are shielded safety needles, mechanical syringes, manual retractable syringes, and shielded syringes, but not automatic retractable syringes. Even when adopting

  1. Evidence for and implications of self-background of radon dosimeters with glass-fiber filters

    NARCIS (Netherlands)

    Put, L.W.; Lembrechts, J.; van der Graaf, E.R.; Stoop, P.

    The first national radon survey in the Netherlands was conducted in 1984 with passive radon dosimeters that contain glass-fiber diffusion filters. During the last few years, measurements of outdoor-radon concentrations and information in the literature suggested to us that these dosimeters may give

  2. Community syringe collection and disposal policies in 16 states.

    Science.gov (United States)

    Turnberg, Wayne L; Jones, T Stephen

    2002-01-01

    To review laws, regulations, and guidelines that affect the collection and disposal of hypodermic needles, syringes, and lancets used outside of professional health care settings (hereafter referred to as "community syringes"). Law and policy analysis. Alabama, California, Florida, Georgia, Hawaii, Massachusetts, Michigan, Minnesota, New Jersey, New York, Ohio, Oregon, Rhode Island, South Carolina, Washington, and Wisconsin. Information on syringe collection and disposal in the community was gathered from federal and state records and state agency personnel. Legally permissible means of syringe collection and disposal available to persons in the community injecting medical treatments and injection drug users. Laws, regulations, or guidelines in 13 states allowed community syringes to be legally discarded in household trash; guidelines for in-trash disposal varied among the states. Only 6 states had laws or regulations that specifically addressed community syringe collection. In 10 states, infectious waste laws and regulations that apply to medical facilities such as clinics would also apply to community syringe collection sites. In the 16 states studied, laws, regulations, and guidelines relating to community syringe collection and disposal were somewhat inconsistent and confusing and presented potential barriers to safe disposal. States should consider amending laws, regulations, and guidelines to promote community syringe collection programs. A national effort is needed to achieve consistent community syringe collection and disposal laws and guidelines for all states. Pharmacists can aid in safe syringe disposal by counseling their patients about safe disposal, providing or selling sharps containers, and accepting used syringes for safe disposal. Pharmacists can join other interested groups in advocating clarification of disposal laws and regulations that favor community programs designed to keep syringes out of the trash so that they can be disposed of as

  3. Development of Syringe/Bottle Hybrids for Sampling Slurries

    International Nuclear Information System (INIS)

    Coleman, C.J.

    1998-01-01

    A convenient and effective sample bottle system based on simple modifications of disposable plastic syringes and bottles has been devised and tested for slurry samples. Syringe/ bottle hybrids (hereafter referred to as syringe bottles) have the convenience of regular flat-bottom bottles with screw cap closures. In addition, the syringe imparts a sliding and adjustable bottom to the bottle that forces the entire contents from the bottle. The system was designed especially to collect samples for high temperature work-ups of DWPF slurry samples. The syringe bottles together with fixed-bottom sample vial inserts would provide the DWPF with convenient and reliable methods for dealing with slurry samples

  4. Syringe injectable electronics

    Science.gov (United States)

    Hong, Guosong; Zhou, Tao; Jin, Lihua; Duvvuri, Madhavi; Jiang, Zhe; Kruskal, Peter; Xie, Chong; Suo, Zhigang; Fang, Ying; Lieber, Charles M.

    2015-01-01

    Seamless and minimally-invasive three-dimensional (3D) interpenetration of electronics within artificial or natural structures could allow for continuous monitoring and manipulation of their properties. Flexible electronics provide a means for conforming electronics to non-planar surfaces, yet targeted delivery of flexible electronics to internal regions remains difficult. Here, we overcome this challenge by demonstrating syringe injection and subsequent unfolding of submicrometer-thick, centimeter-scale macroporous mesh electronics through needles with a diameter as small as 100 micrometers. Our results show that electronic components can be injected into man-made and biological cavities, as well as dense gels and tissue, with > 90% device yield. We demonstrate several applications of syringe injectable electronics as a general approach for interpenetrating flexible electronics with 3D structures, including (i) monitoring of internal mechanical strains in polymer cavities, (ii) tight integration and low chronic immunoreactivity with several distinct regions of the brain, and (iii) in vivo multiplexed neural recording. Moreover, syringe injection enables delivery of flexible electronics through a rigid shell, delivery of large volume flexible electronics that can fill internal cavities and co-injection of electronics with other materials into host structures, opening up unique applications for flexible electronics. PMID:26053995

  5. Mechanized syringe homogenization of human and animal tissues.

    Science.gov (United States)

    Kurien, Biji T; Porter, Andrew C; Patel, Nisha C; Kurono, Sadamu; Matsumoto, Hiroyuki; Scofield, R Hal

    2004-06-01

    Tissue homogenization is a prerequisite to any fractionation schedule. A plethora of hands-on methods are available to homogenize tissues. Here we report a mechanized method for homogenizing animal and human tissues rapidly and easily. The Bio-Mixer 1200 (manufactured by Innovative Products, Inc., Oklahoma City, OK) utilizes the back-and-forth movement of two motor-driven disposable syringes, connected to each other through a three-way stopcock, to homogenize animal or human tissue. Using this method, we were able to homogenize human or mouse tissues (brain, liver, heart, and salivary glands) in 5 min. From sodium dodecyl sulfate-polyacrylamide gel electrophoresis analysis and a matrix-assisted laser desorption/ionization time-of-flight mass spectrometric enzyme assay for prolidase, we have found that the homogenates obtained were as good or even better than that obtained used a manual glass-on-Teflon (DuPont, Wilmington, DE) homogenization protocol (all-glass tube and Teflon pestle). Use of the Bio-Mixer 1200 to homogenize animal or human tissue precludes the need to stay in the cold room as is the case with the other hands-on homogenization methods available, in addition to freeing up time for other experiments.

  6. Open-Source Syringe Pump Library

    Science.gov (United States)

    Wijnen, Bas; Hunt, Emily J.; Anzalone, Gerald C.; Pearce, Joshua M.

    2014-01-01

    This article explores a new open-source method for developing and manufacturing high-quality scientific equipment suitable for use in virtually any laboratory. A syringe pump was designed using freely available open-source computer aided design (CAD) software and manufactured using an open-source RepRap 3-D printer and readily available parts. The design, bill of materials and assembly instructions are globally available to anyone wishing to use them. Details are provided covering the use of the CAD software and the RepRap 3-D printer. The use of an open-source Rasberry Pi computer as a wireless control device is also illustrated. Performance of the syringe pump was assessed and the methods used for assessment are detailed. The cost of the entire system, including the controller and web-based control interface, is on the order of 5% or less than one would expect to pay for a commercial syringe pump having similar performance. The design should suit the needs of a given research activity requiring a syringe pump including carefully controlled dosing of reagents, pharmaceuticals, and delivery of viscous 3-D printer media among other applications. PMID:25229451

  7. Syringe-injectable electronics.

    Science.gov (United States)

    Liu, Jia; Fu, Tian-Ming; Cheng, Zengguang; Hong, Guosong; Zhou, Tao; Jin, Lihua; Duvvuri, Madhavi; Jiang, Zhe; Kruskal, Peter; Xie, Chong; Suo, Zhigang; Fang, Ying; Lieber, Charles M

    2015-07-01

    Seamless and minimally invasive three-dimensional interpenetration of electronics within artificial or natural structures could allow for continuous monitoring and manipulation of their properties. Flexible electronics provide a means for conforming electronics to non-planar surfaces, yet targeted delivery of flexible electronics to internal regions remains difficult. Here, we overcome this challenge by demonstrating the syringe injection (and subsequent unfolding) of sub-micrometre-thick, centimetre-scale macroporous mesh electronics through needles with a diameter as small as 100 μm. Our results show that electronic components can be injected into man-made and biological cavities, as well as dense gels and tissue, with >90% device yield. We demonstrate several applications of syringe-injectable electronics as a general approach for interpenetrating flexible electronics with three-dimensional structures, including (1) monitoring internal mechanical strains in polymer cavities, (2) tight integration and low chronic immunoreactivity with several distinct regions of the brain, and (3) in vivo multiplexed neural recording. Moreover, syringe injection enables the delivery of flexible electronics through a rigid shell, the delivery of large-volume flexible electronics that can fill internal cavities, and co-injection of electronics with other materials into host structures, opening up unique applications for flexible electronics.

  8. Botulinum Toxin Therapy: Is Syringe Type Related to Cost-Effectiveness?

    Science.gov (United States)

    Foglietti, Mark Anthony; Wright, Lauren; Foglietti-Fostyk, Alanna

    2018-03-01

    Clostridium botulinum toxin is effective through cleaving presynaptic proteins at the neuromuscular junction, which prevents the release of acetylcholine and inhibits muscle contraction. Several serotypes of botulinum toxin (BT) exist; however, only 2 types have been approved by the US Food and Drug Administration for commercial and medical use, A and B. Both types of BT must be administered intramuscularly with a syringe, but the type of syringe is the injector's preference. Which syringe type is most efficient in minimizing product waste and most cost-effective for the patient and provider? We performed a single-center, open-label, analytical study using BT therapy and 2 types of syringes for analytics of cost-effectiveness. OnabotulinumtoxinA was the neuromodulator used in this report. Vials (100 U) of BT A were each reconstituted with 2.5 mL of 0.9% sodium chloride, for a final concentration of 4 U/0.1 mL. High-dead-space syringes are compared with low-dead-space syringes: 1-mL tuberculin (TB) luer slip syringe with detachable 25-gauge needle and 1-mL ultrafine insulin syringe with an attached 31-gauge needle, respectively. After each syringe was evacuated, the TB syringe was noted to contain 0.05 mL of the remaining product in the hub. Providers are discarding approximately 2 U of BT per TB syringe product injection. If the physician uses 30 syringes per day, 3 days a week, for 1 year, it equals to a lost revenue of approximately $155,500 per year. To individualize the cost-effective analysis, average quantity of syringes used per patient and overall patient volume must be considered, with corresponding adjustment of cost and units discarded. The American Society of Plastic Surgeons reported that the use of neuromodulators has increased by approximately 797% from 2000 to 2016. During that period, the price of neuromodulators has also increased by approximately 85%. Considering these statistics, the type of syringe used for BT neuromodular injection is a

  9. Combination syringe provides air-free blood samples

    Science.gov (United States)

    Pool, S. L.

    1970-01-01

    Standard syringe and spinal needle are combined in unique manner to secure air-free blood samples. Combination syringe obtains air free samples because air bubbles become insignificant when samples greater than 1 cc are drawn.

  10. The effectiveness and safety of syringe vending machines as a component of needle syringe programmes in community settings.

    Science.gov (United States)

    Islam, Mofizul; Wodak, Alex; Conigrave, Katherine M

    2008-12-01

    Syringe vending machines (SVMs) have been introduced in Europe and Australasia as part of the effort to increase the availability of sterile needles and syringes to injecting drug users (IDUs). This qualitative review of 14 published and grey literature studies examines whether community-based SVMs as a component of a comprehensive needle syringe programme (NSP) assist to reduce the spread of HIV and other blood-borne viruses amongst IDUs. The available evidence suggests that SVMs increase access to sterile injecting equipment, reduce needle and syringe sharing, and are likely to be cost efficient. SVMs also complement other modes of NSP delivery as they are used by IDUs who are less likely to attend staffed NSPs or pharmacies. If installed and properly maintained in a well-chosen location and with the local community well prepared, SVMs can enhance the temporal and geographical availability of sterile injecting equipment.

  11. UV filters for lighting of plants

    Energy Technology Data Exchange (ETDEWEB)

    Doehring, T.; Koefferlein, M.; Thiel, S.; Seidlitz, H.K.; Payer, H.D. [GSF-Forschungszentrum fuer Umwelt und Gesundheit GmbH, Oberschleissheim (Germany)

    1994-12-31

    Different filter glasses are available which provide absorption properties suitable for gradual changes of the spectral UV-B illumination of artificial lighting. Using a distinct set of lamps and filter glasses an acceptable simulation of the UV-B part of natural global radiation can be achieved. The ageing of these and other filter materials under the extreme UV radiation in the lamphouse of a solar simulator is presently unavoidable. This instability can be dealt with only by a precise spectral monitoring and by replacing the filters accordingly. For this reason attempts would be useful to develop real ozone filters which can replace glass filters. In any case chamber experiments require a careful selection of the filter material used and must be accompanied by a continuous UV-B monitoring.

  12. [Morphine self-administration by rats using a pneumatic syringe].

    Science.gov (United States)

    Akiyama, Y; Takayama, S

    1988-06-01

    An apparatus for drug self-administration by rats using a pneumatic syringe was developed by Weeks. A microliter syringe operated by a pneumatic cylinder supplies an accurate volume of drug solution within one second. When coefficient of variation of infusion volume was compared among pneumatic syringe, infusion pump, and peristaltic pump, pneumatic syringe showed higher accuracy in infusion volume than the other two pumps. Since the infusion speed by a pneumatic syringe is very rapid (less than one second per infusion), the effect of infusion speed on reinforcing property of morphine was investigated. When rats self-administered 0.1, 0.3, 1.0, and 3.0 mg/kg/infusion of morphine by pneumatic syringes, the patterns of self-infusion were more stable, the number of self-infusions and the amount self-administered were larger, and a dose-response relationship was clearer in comparison with those self-infused the same doses of morphine for 5.6 seconds by infusion pumps or peristaltic pumps.

  13. Development of glass-fiber high-efficiency particulate air filters of high structural strength on the basis of the establishment of failure mechanisms

    International Nuclear Information System (INIS)

    Ruedinger, V.; Ricketts, C.I.; Wilhelm, J.G.; Alken, W.

    1987-01-01

    Practical experience from routine operation in nuclear installations as well as extensive bench and laboratory testing proved the structural limits of HEPA filters to be very low thus demonstrating the need for improvement of their structural strength. Detailed analysis of the courses and modes of filter failure under the challenge of dry air at high velocities and ambient temperature, together with additional measurements, allowed the establishment of the dominating mechanisms of filter failure. Based on this information, the following three options for effective and economical improvements in filter structural limits exist: (1) an increase in the tensile strength of the filter medium; (2) an increase in the stability of the pack to prevent the swelling of individual pleats; and (3) an increase in the area moment of inertia of the separators and a decrease in the sharpness of their edges. By using a reinforced glass fiber filter medium, the structural strength of standard size HEPA filters was increased to 31 kPa with dry air and beyond 10 kPa with air at high humidity. Prototype filters built with standard glass-fiber media and separators with inclined corrugations exhibited failure pressures of approximately 50 kPa under high velocity airflows. The combination of both types of improvements, together with other measures, will soon lead to even higher HEPA-filter structural strength

  14. Predicting pharmacy syringe sales to people who inject drugs: Policy, practice and perceptions.

    Science.gov (United States)

    Meyerson, Beth E; Davis, Alissa; Agley, Jon D; Shannon, David J; Lawrence, Carrie A; Ryder, Priscilla T; Ritchie, Karleen; Gassman, Ruth

    2018-06-01

    Pharmacies have much to contribute to the health of people who inject drugs (PWID) and to community efforts in HIV and hepatitis C (HCV) prevention through syringe access. However, little is known about what predicts pharmacy syringe sales without a prescription. To identify factors predicting pharmacy syringes sales to PWID. A hybrid staggered online survey of 298 Indiana community pharmacists occurred from July-September 2016 measuring pharmacy policy, practice, and pharmacist perceptions about syringe sales to PWID. Separate bivariate logistical regressions were followed by multivariable logistic regression to predict pharmacy syringe sales and pharmacist comfort dispensing syringes to PWID. Half (50.5%) of Indiana pharmacies sold syringes without a prescription to PWID. Pharmacy syringe sales was strongly associated with pharmacist supportive beliefs about syringe access by PWID and their comfort level selling syringes to PWID. Notably, pharmacies located in communities with high rates of opioid overdose mortality were 56% less likely to sell syringes without a prescription than those in communities with lower rates. Pharmacist comfort dispensing syringes was associated with being male, working at a pharmacy that sold syringes to PWID and one that stocked naloxone, having been asked about syringe access by medical providers, and agreement that PWID should be able to buy syringes without a prescription. As communities with high rates of opioid overdose mortality were less likely to have pharmacies that dispensed syringes to PWID, a concerted effort with these communities and their pharmacies should be made to understand opportunities to increase syringe access. Future studies should explore nuances between theoretical support for syringe access by PWID without a prescription and actual dispensing behaviors. Addressing potential policy conflicts and offering continuing education on non-prescription syringe distribution for pharmacists may improve comfort

  15. The use of nylon and glass fiber filter separators with different pore sizes in air-cathode single-chamber microbial fuel cells

    KAUST Repository

    Zhang, Xiaoyuan; Cheng, Shaoan; Huang, Xia; Logan, Bruce E.

    2010-01-01

    on performance. Larger pore nylon mesh were used that had regular mesh weaves with pores ranging from 10 to 160 μm, while smaller pore-size nylon filters (0.2-0.45 μm) and glass fiber filters (0.7-2.0 μm) had a more random structure. The pore size of both types

  16. Non-destructive vacuum decay method for pre-filled syringe closure integrity testing compared with dye ingress testing and high-voltage leak detection.

    Science.gov (United States)

    Simonetti, Andrea; Amari, Filippo

    2015-01-01

    In reaction to the limitations of the traditional sterility test methods, in 2008, the U.S. Food and Drug Administration issued the guidance "Container and Closure System Integrity Testing in Lieu of Sterility Testing as a Component of the Stability Protocol for Sterile Products" encouraging sterile drug manufacturers to use properly validated physical methods, apart from conventional microbial challenge testing, to confirm container closure integrity as part of the stability protocol. The case study presented in this article investigated the capability of four container closure integrity testing methods to detect simulated defects of different sizes and types on glass syringes, prefilled both with drug product intended for parenteral administration and sterile water. The drug product was a flu vaccine (Agrippal, Novartis Vaccines, Siena, Italy). Vacuum decay, pharmacopoeial dye ingress test, Novartis specific dye ingress test, and high-voltage leak detection were, in succession, the methods involved in the comparative studies. The case study execution was preceded by the preparation of two independent sets of reference prefilled syringes, classified, respectively, as examples of conforming to closure integrity requirements (negative controls) and as defective (positive controls). Positive controls were, in turn, split in six groups, three of with holes laser-drilled through the prefilled syringe glass barrel, while the other three with capillary tubes embedded in the prefilled syringe plunger. These reference populations were then investigated by means of validated equipment used for container closure integrity testing of prefilled syringe commercial production; data were collected and analyzed to determine the detection rate and the percentage of false results. Results showed that the vacuum decay method had the highest performance in terms of detection sensitivity and also ensured the best reliability and repeatability of measurements. An innovative technical

  17. The use of nylon and glass fiber filter separators with different pore sizes in air-cathode single-chamber microbial fuel cells

    KAUST Repository

    Zhang, Xiaoyuan

    2010-01-01

    Separators are needed in microbial fuel cells (MFCs) to reduce electrode spacing and preventing electrode short circuiting. The use of nylon and glass fiber filter separators in single-chamber, air-cathode MFCs was examined for their effect on performance. Larger pore nylon mesh were used that had regular mesh weaves with pores ranging from 10 to 160 μm, while smaller pore-size nylon filters (0.2-0.45 μm) and glass fiber filters (0.7-2.0 μm) had a more random structure. The pore size of both types of nylon filters had a direct and predictable effect on power production, with power increasing from 443 ± 27 to 650 ± 7 mW m-2 for pore sizes of 0.2 and 0.45 μm, and from 769 ± 65 to 941 ± 47 mW m-2 for 10 to 160 μm. In contrast, changes in pore sizes of the glass fiber filters resulted in a relatively narrow change in power (732 ± 48 to 779 ± 43 mW m-2) for pore sizes of 0.7 to 2 μm. An ideal separator should increase both power density and Coulombic efficiency (CE). However, CEs measured for the different separators were inversely correlated with power production, demonstrating that materials which reduced the oxygen diffusion into the reactor also hindered proton transport to the cathode, reducing power production through increased internal resistance. Our results highlight the need to develop separators that control oxygen transfer and facilitate proton transfer to the cathode. © 2010 The Royal Society of Chemistry.

  18. Dedusting in the glass industry; Depoussierage en verrerie

    Energy Technology Data Exchange (ETDEWEB)

    Tackels, G. [Saint-Gobain Concetpions Verrieres (France); Depauw, J.P. [Procedair (France); Myrope, A. [Lurgi (France)

    2000-07-01

    Here are gathered several articles concerning the dedusting in the glass industry. At present, about a third of the European glass furnaces are fitted out with filters. The best industrially available techniques used for the abatement of glass dust releases are: handle filters and electro-filters. Their principles of separation, characteristics of manufacturing and performance are detailed. (O.M.)

  19. A device for uranium series leaching from glass fiber in HEPA filter

    International Nuclear Information System (INIS)

    Gye-Nam Kim; Hye-Min Park; Wang-Kyu Choi; Jei-Kwon Moon

    2012-01-01

    For the disposal of a high efficiency particulate air (HEPA) glass filter into the environment, the glass fiber should be leached to lower its radioactive concentration to the clearance level. To derive an optimum method for the removal of uranium series from a HEPA glass fiber, five methods were applied in this study. That is, chemical leaching by a 4.0 M HNO 3 -0.1 M Ce(IV) solution, chemical leaching by a 5 wt% NaOH solution, chemical leaching by a 0.5 M H 2 O 2 -1.0 M Na 2 CO 3 solution, chemical consecutive chemical leaching by a 4.0 M HNO 3 solution, and repeated chemical leaching by a 4.0 M HNO 3 solution were used to remove the uranium series. The residual radioactivity concentrations of 238 U, 235 U, 226 Ra, and 234 Th in glass after leaching for 5 h by the 4.0 M HNO 3 -0.1 M Ce(IV) solution were 2.1, 0.3, 1.1, and 1.2 Bq/g. The residual radioactivity concentrations of 238 U, 235 U, 226 Ra, and 234 Th in glass after leaching for 36 h by 4.0 M HNO 3 -0.1 M Ce(IV) solution were 76.9, 3.4, 63.7, and 71.9 Bq/g. The residual radioactivity concentrations of 238 U, 235 U, 226 Ra, and 234 Th in glass after leaching for 8 h by a 0.5 M H 2 O 2 -1.0 M Na 2 CO 3 solution were 8.9, 0.0, 1.91, and 6.4 Bq/g. The residual radioactivity concentrations of 238 U, 235 U, 226 Ra, and 234 Th in glass after consecutive leaching for 8 h by the 4.0 M HNO 3 solution were 2.08, 0.12, 1.55, and 2.0 Bq/g. The residual radioactivity concentrations of 238 U, 235 U, 226 Ra, and 234 Th in glass after three repetitions of leaching for 3 h by the 4.0 M HNO 3 solution were 0.02, 0.02, 0.29, and 0.26 Bq/g. Meanwhile, the removal efficiencies of 238 U, 235 U, 226 Ra, and 234 Th from the waste solution after its precipitation-filtration treatment with NaOH and alum for reuse of the 4.0 M HNO 3 waste solution were 100, 100, 93.3, and 100%. (author)

  20. Retention and variability of hydrogen (H2) samples stored in plastic syringes

    DEFF Research Database (Denmark)

    Rumessen, J J; Gudmand-Høyer, E

    1987-01-01

    The utility of two brands of 20 ml plastic syringes for storage of hydrogen (H2) samples as obtained in H2 breath tests were studied. Plastipak syringes were found to be significantly better with regard to the stability of the H2 concentration and the variability between the H2 samples. Storage...... of the H2 samples in Plastipak syringes at 5 degrees C significantly improved the H2 retention, whereas refrigeration of H2 samples stored in Once syringes did not reduce H2 loss. Storage of H2 samples in refrigerated plastic syringes is efficient and reliable for several days if syringes with minimal...... sample variation are used....

  1. Not sold here: limited access to legally available syringes at pharmacies in Tijuana, Mexico.

    Science.gov (United States)

    Pollini, Robin A; Rosen, Perth C; Gallardo, Manuel; Robles, Brenda; Brouwer, Kimberly C; Macalino, Grace E; Lozada, Remedios

    2011-05-24

    Sterile syringe access is a critical component of HIV prevention programs. Although retail pharmacies provide convenient outlets for syringe access, injection drug users (IDUs) may encounter barriers to syringe purchase even where purchase without a prescription is legal. We sought to obtain an objective measure of syringe access in Tijuana, Mexico, where IDUs report being denied or overcharged for syringes at pharmacies. Trained "mystery shoppers" attempted to buy a 1 cc insulin syringe according to a predetermined script at all retail pharmacies in three Tijuana neighborhoods. The same pharmacies were surveyed by telephone regarding their syringe sales policies. Data on purchase attempts were analyzed using basic statistics to obtain an objective measure of syringe access and compared with data on stated sales policies to ascertain consistency. Only 46 (28.4%) of 162 syringe purchase attempts were successful. Leading reasons for unsuccessful attempts were being told that the pharmacy didn't sell syringes (35.3%), there were no syringes in stock (31.0%), or a prescription was required (20.7%). Of 136 pharmacies also surveyed by telephone, a majority (88.2%) reported selling syringes but only one-third (32.5%) had a successful mystery shopper purchase; the majority of unsuccessful purchases were attributed to being told the pharmacy didn't sell syringes. There was similar discordance regarding prescription policies: 74 pharmacies said in the telephone survey that they did not require a prescription for syringes, yet 10 of these pharmacies asked the mystery shopper for a prescription. IDUs in Tijuana have limited access to syringes through retail pharmacies and policies and practices regarding syringe sales are inconsistent. Reasons for these restrictive and inconsistent practices must be identified and addressed to expand syringe access, reduce syringe sharing and prevent HIV transmission.

  2. Drug residues in used syringes in Switzerland: A comparative study.

    Science.gov (United States)

    Lefrançois, Elodie; Augsburger, Marc; Esseiva, Pierre

    2018-05-01

    Harm reduction services, including needle-exchange programmes, have been implemented in Switzerland for over 20 years. Their main aim is to lessen the negative social and/or physical consequences associated with illicit drug consumption and, therefore, improve prevention messages. To this end, knowledge of illicit drug consumption practices is necessary. Periodic self-report surveys are the primary source of data for monitoring drug users' behaviour. Analysis of residual content of used syringes can bring further and objective knowledge about consumed products through analytically confirmed data. Used syringes were sampled in 2 syringe-exchange facilities in Lausanne. These structures are a bus where the users bring back their syringes (ABS) and an automatic injecting kit dispenser (AIKD). Once syringes were collected, a validated gas chromatography-mass spectrometry (GC-MS) method was implemented in order to detect drugs (licit or illicit) contained in the residual content of used syringes. Cocaine was the most common drug detected alone (39% in ABS and 31% in AIKD), followed by the simultaneous detection of heroin and cocaine (12% and 17%) and heroin and midazolam (12% and 17%). The differences between the illicit drugs distribution of used syringes collected in AIKD and ABS were not statistically significant. Analysis of residual content of used syringes as a monitoring tool is an original approach that has already led to a better understanding of the habits of drug-injection users. Over the long term, this approach is a powerful tool to track and detect new consumption practices in a quasi-real-time. Copyright © 2017 John Wiley & Sons, Ltd.

  3. Second Order Harmonics Suppression With Glass Filters for Synchrotron UV Radiation Calibration Measurement

    CERN Document Server

    Burattini, E; Gambicorti, L; Malvezzi, F; Marcelli, A; Monti, F; Pace, E

    2005-01-01

    This development is the latest result of the cooperation between the National Laboratories of Frascati and the Department of Astronomy and Space Science of the University of Florence to improve the capabilities of the existing DXR-2 beam line at the DAΦNE-LIGHT laboratories. This collaboration has assessed a new facility in order to characterize optics and sensors in a wide spectral range (ranging from VUV to IR). Previous measurements [1] have highlighted some limitations in the present setup, as higher signal levels due to the diffracted radiation of the grating in the second order have to be removed to allow an accurate detection. In this work a glass filter is used to remove such spurious signal present in the spectral region with λ > 360 nm. The characteristics of the filter and its application to the optical system used to measure the sensitivity of a diamond-based photoconductor have been discussed.

  4. Commentary on Vorobjov et al., "Comparison of injection drug users who obtain syringes from pharmacies and syringe exchange programs in Tallinn, Estonia"

    Directory of Open Access Journals (Sweden)

    Werb Daniel

    2009-01-01

    Full Text Available Abstract Recent data suggest that globally, between 5% and 10% of all new HIV cases are the result of unsafe injecting practices, and experts agree that reducing these practices is key to tackling the spread of HIV. And yet, despite the overwhelming evidence that providing sterile syringes to injection drug users (IDU through syringe exchange programs (SEPs or other means is an effective way of reducing HIV transmission among high-risk subpopulations, IDU in most settings still do not have access to sterile injecting equipment or if they do, access remains too restricted to effectively reduce the risk of HIV transmission. Vorobjov and colleagues have presented in this journal an interesting and timely study from Estonia comparing individuals who obtain syringes from SEPs and those who obtain syringes from pharmacies. As the authors point out, Estonia faces an unacceptably high HIV incidence rate of 50 new HIV cases per 100,000, this rate driven primarily by injection drug use. As such, the authors argue that Estonia's SEP network does not have the capacity to serve a growing IDU population at risk of transmitting HIV and pharmacy dispensation of clean syringes may be one potential approach to decreasing syringe sharing among high-risk injectors. It may be overly optimistic to consider the impact of higher threshold interventions such as pharmacy-based SEPs, given that IDU populations that engage in HIV risk behaviours such as syringe sharing are often hidden or hard to reach. Despite the need for a cautious approach, however, the findings presented by Vorobjov et al. may chart one potential course towards a more comprehensive societal response to reducing the health harms associated with injection drug use.

  5. In-syringe dispersive liquid-liquid microextraction with liquid chromatographic determination of synthetic pyrethroids in surface water

    Directory of Open Access Journals (Sweden)

    Saeed S. Albaseer

    2012-03-01

    Full Text Available An indigenously fabricated in laboratory glass syringe was used for in-syringe dispersive liquid-liquid microextraction (is-DLLME and preconcentration of synthetic pyrethroids (SPs from surface waters suitable for their determination by high performance liquid chromatography. In contrast to classical DLLME, is-DLLME allows the use of lighter-than-water organic solvents and the analysis of environmental contaminants’ samples without prior filtration, which is of great importance due to the high affinity of pyrethroids to adsorb to solid particulates present in environmental samples. The effects of various parameters on the extraction efficiency were evaluated and optimized systemically using one-factor-at-a-time method (OFAT and statistically using full factorial design (24. Three SPs (viz.; cypermethrin, resmethrin and permethrin were analyzed. The method showed good accuracy with RSD% in the range of of 4.8–6.9%. The method detection limits of the three pesticides ranged from 0.14 to 0.16 ng mL-1. The proposed method was applied for the determination of synthetic pyrethroids in lake water

  6. Options for reducing HIV transmission related to the dead space in needles and syringes.

    Science.gov (United States)

    Zule, William A; Pande, Poonam G; Otiashvili, David; Bobashev, Georgiy V; Friedman, Samuel R; Gyarmathy, V Anna; Des Jarlais, Don C

    2018-01-15

    When shared by people who inject drugs, needles and syringes with different dead space may affect the probability of HIV and hepatitis C virus (HCV) transmission differently. We measured dead space in 56 needle and syringe combinations obtained from needle and syringe programs across 17 countries in Europe and Asia. We also calculated the amounts of blood and HIV that would remain in different combinations following injection and rinsing. Syringe barrel capacities ranged from 0.5 to 20 mL. Needles ranged in length from 8 to 38 mm. The average dead space was 3 μL in low dead space syringes with permanently attached needles, 13 μL in high dead space syringes with low dead space needles, 45 μL in low dead space syringes with high dead space needles, and 99 μL in high dead space syringes with high dead space needles. Among low dead space designs, calculated volumes of blood and HIV viral burden were lowest for low dead space syringes with permanently attached needles and highest for low dead space syringes with high dead space needles. The dead space in different low dead space needle and syringe combinations varied substantially. To reduce HIV transmission related to syringe sharing, needle and syringe programs need to combine this knowledge with the needs of their clients.

  7. The Washington Needle Depot: fitting healthcare to injection drug users rather than injection drug users to healthcare: moving from a syringe exchange to syringe distribution model

    Directory of Open Access Journals (Sweden)

    Glickman Andrea

    2010-01-01

    Full Text Available Abstract Needle exchange programs chase political as well as epidemiological dragons, carrying within them both implicit moral and political goals. In the exchange model of syringe distribution, injection drug users (IDUs must provide used needles in order to receive new needles. Distribution and retrieval are co-existent in the exchange model. Likewise, limitations on how many needles can be received at a time compel addicts to have multiple points of contact with professionals where the virtues of treatment and detox are impressed upon them. The centre of gravity for syringe distribution programs needs to shift from needle exchange to needle distribution, which provides unlimited access to syringes. This paper provides a case study of the Washington Needle Depot, a program operating under the syringe distribution model, showing that the distribution and retrieval of syringes can be separated with effective results. Further, the experience of IDUs is utilized, through paid employment, to provide a vulnerable population of people with clean syringes to prevent HIV and HCV.

  8. Efficacy trial of Camouflage Syringe to reduce dental fear and anxiety.

    Science.gov (United States)

    Ujaoney, S; Mamtani, M; Thakre, T; Tote, J; Hazarey, V; Hazarey, P; Kulkarni, H

    2013-12-01

    Dental fear and anxiety in early childhood are widely prevalent and contribute to dental problems and behaviour in adulthood. Novel ways to reduce dental fear and anxiety in children are needed. Our aim was to conduct an efficacy trial of a novel Camouflage Syringe to reduce dental fear and anxiety in children. randomised controlled trial of efficacy of the Camouflage Syringe. We designed a Camouflage Syringe with a toy-like appearance that veils the conventional syringe to permit topical application and injection of local anaesthesia and ensure more involvement of the patient in the treatment process. We conducted a concurrent parallel, randomised controlled trial (NCT01398007) on the efficacy of this Camouflage Syringe to reduce the dental fear and anxiety in children seeking dental treatment who required the use of local anaesthesia. Using Venham's clinical rating scale, Venham's picture test, parental stress questionnaire and recall questionnaire, the efficacy of the Camouflage Syringe to reduce dental fear and anxiety ranged from 82% to 97% for various outcomes and from 60% to 100% for prevention of related adverse outcomes. For all outcomes, the number needed to treat was close to unity. Our results strongly favour the use of Camouflage Syringe to reduce dental fear and anxiety in children.

  9. Attitudes of North Carolina law enforcement officers toward syringe decriminalization

    Science.gov (United States)

    Davis, Corey S.; Johnston, Jill; Zerden, Lisa de Saxe; Clark, Katie; Castillo, Tessie; Childs, Robert

    2015-01-01

    Background North Carolina, like much of the U.S. South, is disproportionately affected by HIV and hepatitis. This persistently high disease burden may be driven in part by laws that criminalize the possession and distribution of syringes for illicit drug use. Legal change to decriminalize syringes may reduce infection rates in the state, but is unlikely absent support from law enforcement actors. Methods We analyzed the responses of 350 North Carolina law enforcement officers to a confidential, anonymous survey. The survey instrument collected data regarding self-reported needle-stick injury (NSI), blood borne disease risk perception and attitudes toward syringe decriminalization. Results 82% of respondents reported that contracting HIV was a “big concern” for them. 3.8% of respondents reported ever receiving a job-related NSI, a rate of 36 NSI per 10,000 officer-years. Majorities of respondents reported positive views regarding syringe decriminalization, with approximately 63% agreeing that it would be “good for the community” and 60% agreeing that it would be “good for law enforcement.” Black and female officers were significantly less likely to agree that on-the-job NSI was a “big concern” and significantly more likely to agree that it would be good for law enforcement. Conclusions These findings suggest that many North Carolina LEOs understand the public health benefits of syringe access programs and may be inclined to support syringe decriminalization legislation. Further research is indicated to determine the causes of observed differences in perceptions of bloodborne disease risk and attitudes toward syringe decriminalization by race and sex. PMID:25193720

  10. Transient radiation effects in D.O.I. optical materials: Schott filter glass

    International Nuclear Information System (INIS)

    Simmons-Potter, K.

    1998-07-01

    Department of Energy and Defense Programs systems are becoming increasingly reliant on the use of optical technologies that must perform under a range of ionizing radiation environments. In particular, the radiation response of materials under consideration for applications in direct optical initiation (D.O.I.) schemes must be well characterized. In this report, transient radiation effects observed in Schott filter glass S-7010 are characterized. Under gamma exposure with 2 MeV photons in a 20--30 nsec pulse, the authors observe strong initial induced fluorescence in the red region of the spectrum followed by significant induced absorption over the same spectral region. Peak induced absorption coefficients of 0.113 cm -1 and 0.088 cm -1 were calculated at 800 nm and 660 nm respectively

  11. 21 CFR 870.1670 - Syringe actuator for an injector.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Syringe actuator for an injector. 870.1670 Section 870.1670 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... actuator for an injector. (a) Identification. A syringe actuator for an injector is an electrical device...

  12. Survival of Hepatitis C Virus in Syringes: Implication for Transmission among Injection Drug Users

    Science.gov (United States)

    Paintsil, Elijah; He, Huijie; Peters, Christopher; Lindenbach, Brett D.; Heimer, Robert

    2010-01-01

    Background We hypothesized that the high prevalence of HCV among injection drug users (IDUs) might be due to prolonged virus survival in contaminated syringes. Methods We developed a microculture assay to examine the viability of HCV. Syringes were loaded with blood spiked with HCV reporter virus (Jc1/GLuc2A) to simulate two scenarios of residual volumes; low (2 μl) void volume for 1-ml insulin syringes, and high (32 μl) void volume for 1-ml tuberculin syringes. Syringes were stored at 4°C, 22°C, and 37°C for up to 63 days before testing for HCV infectivity using luciferase activity. Results The virus decay rate was biphasic (t½ α = 0.4h and t½β = 28h). Insulin syringes failed to yield viable HCV beyond day one at all storage temperatures except for 4o in which 5% of syringes yielded viable virus on day 7. Tuberculin syringes yielded viable virus from 96%, 71%, and 52% of syringes following storage at 4o, 22° and 37o for 7 days, respectively, and yielded viable virus up to day 63. Conclusions The high prevalence of HCV among IDUs may be partly due to the resilience of the virus and the syringe type. Our findings may be used to guide prevention strategies. PMID:20726768

  13. Epinephrine syringe exchange events in a paediatric cardiovascular ICU: analysing the storm.

    Science.gov (United States)

    Achuff, Barbara-Jo; Achuff, Jameson C; Park, Hwan H; Moffett, Brady; Acosta, Sebastian; Rusin, Craig G; Checchia, Paul A

    2018-03-01

    Introduction Haemodynamically unstable patients can experience potentially hazardous changes in vital signs related to the exchange of depleted syringes of epinephrine to full syringes. The purpose was to determine the measured effects of epinephrine syringe exchanges on the magnitude, duration, and frequency of haemodynamic disturbances in the hour after an exchange event (study) relative to the hours before (control). Materials and methods Beat-to-beat vital signs recorded every 2 seconds from bedside monitors for patients admitted to the paediatric cardiovascular ICU of Texas Children's Hospital were collected between 1 January, 2013 and 30 June, 2015. Epinephrine syringe exchanges without dose/flow change were obtained from electronic records. Time, magnitude, and duration of changes in systolic blood pressure and heart rate were characterised using Matlab. Significant haemodynamic events were identified and compared with control data. In all, 1042 syringe exchange events were found and 850 (81.6%) had uncorrupted data for analysis. A total of 744 (87.5%) exchanges had at least 1 associated haemodynamic perturbation including 2958 systolic blood pressure and 1747 heart-rate changes. Heart-rate perturbations occurred 37% before exchange and 63% after exchange, and 37% of systolic blood pressure perturbations happened before syringe exchange, whereas 63% occurred after syringe exchange with significant differences found in systolic blood pressure frequency (pexchange events.

  14. Improvement of the skin sparing characteristics of the clinac 4 by the use of leaded glass electron filters

    International Nuclear Information System (INIS)

    Ames, T.E.; Saylor, W.; Dillard, M.

    1977-01-01

    Ionization chamber measurements were taken to determine the Relative Skin Dose from the Varian Clinac 4 (lead flattening filter). The effect of blocking tray material, field size, and scatterer-skin distance on the relative skin dose was investigated both on and off the central axis. It was found that the leaded glass tray enhanced the skin sparing effect of the beam by 25 to 30 percent

  15. Spring-loaded syringe for multiple rapid injections

    Directory of Open Access Journals (Sweden)

    C R Srinivas

    2017-01-01

    Full Text Available Mesotherapy refers to multiple injections of small quantity of the drug over a large area. The mesoguns available are expensive and the motor-driven models tends to waste the expensive material to be injected since the plunger stops after injecting without recoil. We searched for a less expensive device which would inject like the mesogun and still not waste the solution. On searching the web, we identified a spring-loaded syringe. We describe the assembly and use of this inexpensive syringe for delivering multiple injections with minimal wastage.

  16. Spring-loaded Syringe for Multiple Rapid Injections

    Science.gov (United States)

    Srinivas, CR; Somani, Anirudh; Shashidharan Nair, CK; Mylswamy, Thirumurthy

    2017-01-01

    Mesotherapy refers to multiple injections of small quantity of the drug over a large area. The mesoguns available are expensive and the motor-driven models tends to waste the expensive material to be injected since the plunger stops after injecting without recoil. We searched for a less expensive device which would inject like the mesogun and still not waste the solution. On searching the web, we identified a spring-loaded syringe. We describe the assembly and use of this inexpensive syringe for delivering multiple injections with minimal wastage. PMID:28529423

  17. Methods To Determine the Silicone Oil Layer Thickness in Sprayed-On Siliconized Syringes.

    Science.gov (United States)

    Loosli, Viviane; Germershaus, Oliver; Steinberg, Henrik; Dreher, Sascha; Grauschopf, Ulla; Funke, Stefanie

    2018-01-01

    The silicone lubricant layer in prefilled syringes has been investigated with regards to siliconization process performance, prefilled syringe functionality, and drug product attributes, such as subvisible particle levels, in several studies in the past. However, adequate methods to characterize the silicone oil layer thickness and distribution are limited, and systematic evaluation is missing. In this study, white light interferometry was evaluated to close this gap in method understanding. White light interferometry demonstrated a good accuracy of 93-99% for MgF 2 coated, curved standards covering a thickness range of 115-473 nm. Thickness measurements for sprayed-on siliconized prefilled syringes with different representative silicone oil distribution patterns (homogeneous, pronounced siliconization at flange or needle side, respectively) showed high instrument (0.5%) and analyst precision (4.1%). Different white light interferometry instrument parameters (autofocus, protective shield, syringe barrel dimensions input, type of non-siliconized syringe used as base reference) had no significant impact on the measured average layer thickness. The obtained values from white light interferometry applying a fully developed method (12 radial lines, 50 mm measurement distance, 50 measurements points) were in agreement with orthogonal results from combined white and laser interferometry and 3D-laser scanning microscopy. The investigated syringe batches (lot A and B) exhibited comparable longitudinal silicone oil layer thicknesses ranging from 170-190 nm to 90-100 nm from flange to tip and homogeneously distributed silicone layers over the syringe barrel circumference (110- 135 nm). Empty break-loose (4-4.5 N) and gliding forces (2-2.5 N) were comparably low for both analyzed syringe lots. A silicone oil layer thickness of 100-200 nm was thus sufficient for adequate functionality in this particular study. Filling the syringe with a surrogate solution including short

  18. Simple extraction method using syringe filter for detection of ethephon in tomatoes by negative-ion mode liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Cho, Soon-Kil; Cho, Ji-Mi; Abd El-Aty, A M; Rahman, Md Musfiqur; Choi, Jeong-Heui; Seo, Young-Jun; Shin, Ho-Chul; Shim, Jae-Han

    2015-10-01

    In this study, a simple, rapid, and sensitive method was developed for the extraction of ethephon from homogenized tomatoes that does not require a cleanup procedure. In a syringe filter, three distinct layers - aqueous, acetonitrile, and n-hexane - are clearly separated after storage at -80 °C for 5-10 min. A Dionex IonPac column was used to separate the analyte before detection using negative-ion mode liquid chromatography with tandem mass spectrometry (LC/MS/MS). The matrix effect of the tested analyte was negligibly small and the matched calibration showed a good linearity over a concentration range of 0.01-1.0 mg/kg with a correlation coefficient (R(2) ) of 0.9998. The recovery at three fortification levels (0.1, 0.5 and 1.0 mg/kg) was between 82.9 and 108.6% with relative standard deviations (RSDs) <5.0%. The limit of quantification (0.03 mg/kg) was lower than the maximum residue limit (3 mg/kg) set by the Ministry of Food and Drug Safety, Republic of Korea. From a field trial, the method developed herein was applied to calculate the decline pattern and predict the pre-harvest residue limits of ethephon in tomatoes. In conclusion, the proposed sample preparation is feasible for the detection of hydrophilic analytes in tomatoes. Copyright © 2015 John Wiley & Sons, Ltd.

  19. Making Nasopalatine Blocks Comfortable: A Randomised Prospective Clinical Comparison of Pain Associated with the Injection Using an Insulin Syringe and a Standard Disposable 3 mL Syringe.

    Science.gov (United States)

    Prabhu, Sundararaman; Faizel, Syed; Pahlajani, Vedant; Prabhu, Shweta Jha

    2013-12-01

    This study was conducted to compare and evaluate the pain associated with administration of Nasopalatine blocks using a disposable insulin syringe and the conventional disposable 3 mL syringe. Forty patients requiring intraalveolar extractions of maxillary central incisors were randomly assigned to two groups of 20 patients each; one (Group A) received the nasopalatine block with a standard 3mL syringe and the other (Group B) received the block with an insulin syringe. Patients were asked to rate the pain associated with the injection on a visual analog scale (VAS) and the results were analysed using a Chi Square Test. The mean VAS score for Group A and B was 1.55 and 1 respectively. Chi Square value was calculated to be 8.603 (degree of freedom= 3, P value= 0.0351). There were no differences in the effectiveness of anesthesia between the groups. Pain associated with administration of the nasopalatine blocks may be significantly mitigated by using the Insulin syringe.

  20. Syringe access for the prevention of blood borne infections among injection drug users

    Directory of Open Access Journals (Sweden)

    Rich Josiah D

    2003-11-01

    Full Text Available Abstract Background Approximately one-third of acquired immunodeficiency syndrome cases in the United States are associated with the practice of sharing of injection equipment and are preventable through the once-only use of syringes, needles and other injection equipment. Discussion Sterile syringes may be obtained legally by 4 methods depending on the state. They may be purchased over the counter, prescribed, obtained at syringe exchange programs or furnished by authorized agencies. Each of these avenues has advantages and disadvantages; therefore, legal access through all means is the most likely way to promote the use of sterile syringes. Summary By assisting illicit drug injectors to obtain sterile syringes the primary care provider is able to reduce the incidence of blood borne infections, and educate patients about safe syringe disposal. The provider is also able to initiate discussion about drug use in a nonjudgmental manner and to offer care to patients who are not yet ready to consider drug treatment.

  1. Racial differences in acquisition of syringes from pharmacies under conditions of legal but restricted sales.

    Science.gov (United States)

    Costenbader, Elizabeth C; Zule, William A; Coomes, Curtis C

    2010-09-01

    Injecting drug users (IDUs) are at increased risk of acquiring and transmitting HIV and other bloodborne pathogens through the multi-person use of syringes. Although research has shown that increased access to syringes through syringe exchange programs (SEPs) is an effective strategy to reduce risky injection practices many areas of the United States still do not have SEPs. In the absence of SEPs, legislation allowing pharmacies over-the-counter sales of syringes has also been shown to reduce syringe sharing. The success of pharmacy sales however is limited by other legal stipulations, such as drug paraphernalia laws, which in turn may contribute to fear among IDUs about being caught purchasing and carrying syringes. Between 2003 and 2006, 851 out-of-treatment IDUs were recruited using street outreach in the Raleigh-Durham (North Carolina) area. Data were collected using audio-computer assisted interview (ACASI) technology. Multiple logistic regression analyses were performed to assess factors associated with purchasing syringes from pharmacies. In our study sample, African-American IDUs were one-fifth as likely as white IDUs to report pharmacies as their primary source of syringes. Given the absence of syringe exchange programs and the relatively high prevalence of HCV and HIV among IDUs in the Raleigh-Durham area, the limited use of pharmacies as a source of syringes among African-American IDUs in this study sample is problematic. The study findings support the need for effective multilevel interventions to increase access to clean needles in this population, as well as for policy interventions, such as legalization of SEPs and elimination of penalties for carrying syringes, to reduce harm and eliminate the health threats posed by receptive syringe sharing. Copyright 2010 Elsevier B.V. All rights reserved.

  2. Variability in syringe components and its impact on functionality of delivery systems.

    Science.gov (United States)

    Rathore, Nitin; Pranay, Pratik; Eu, Bruce; Ji, Wenchang; Walls, Ed

    2011-01-01

    Prefilled syringes and autoinjectors are becoming increasingly common for parenteral drug administration primarily due to the convenience they offer to the patients. Successful commercialization of such delivery systems requires thorough characterization of individual components. Complete understanding of various sources of variability and their ranking is essential for robust device design. In this work, we studied the impact of variability in various primary container and device components on the delivery forces associated with syringe injection. More specifically, the effects of barrel size, needle size, autoinjector spring force, and frictional forces have been evaluated. An analytical model based on underlying physics is developed that can be used to fully characterize the design space for a product delivery system. Use of prefilled syringes (syringes prefilled with active drug) is becoming increasingly common for injectable drugs. Compared to vials, prefilled syringes offer higher dose accuracy and ease of use due to fewer steps required for dosage. Convenience to end users can be further enhanced through the use of prefilled syringes in combination with delivery devices such as autoinjectors. These devices allow patients to self-administer the drug by following simple steps such as pressing a button. These autoinjectors are often spring-loaded and are designed to keep the needle tip shielded prior to injection. Because the needle is not visible to the user, such autoinjectors are perceived to be less invasive than syringes and help the patient overcome the hesitation associated with self-administration. In order to successfully develop and market such delivery devices, we need to perform an in-depth analysis of the components that come into play during the activation of the device and dose delivery. Typically, an autoinjector is activated by the press of a button that releases a compressed spring; the spring relaxes and provides the driving force to push the

  3. Direct observation of syringeal muscle function in songbirds and a parrot

    DEFF Research Database (Denmark)

    Larsen, Ole Næsbye; Goller, Franz

    2002-01-01

    on the syrinx. Contraction of m. tracheobronchialis ventralis enlarges the syringeal lumen and thus increases airflow by abducting the LL but does not affect the ML. The largest syringeal muscle, m. syringealis ventralis, plays a minor role, if any, in direct aperture control and thus in gating airflow...... the LTMs further into the tracheal lumen but does not close the syringeal aperture fully. The intrinsic deep muscle, m. syringealis profundus, abducts the LTMs through cranio-laterad movement of a paired, protruding half-ring. The weakly developed extrinsic m. sternotrachealis seems to increase tension......The role of syringeal muscles in controlling the aperture of the avian vocal organ, the syrinx, was evaluated directly for the first time by observing and filming through an endoscope while electrically stimulating different muscle groups of anaesthetised birds. In songbirds (brown thrashers...

  4. Syringe Sharing Among a Prospective Cohort of Street-Involved Youth: Implications for Needle Distribution Programs.

    Science.gov (United States)

    Bozinoff, Nikki; Wood, Evan; Dong, Huiru; Richardson, Lindsey; Kerr, Thomas; DeBeck, Kora

    2017-09-01

    The sharing of previously used syringes is associated with the transmission of Hepatitis C and HIV. This longitudinal study examines syringe borrowing and syringe lending within a prospective cohort of street-involved youth in Vancouver, Canada. From September 2005 to May 2014, data were collected from the At-Risk Youth Study, a cohort of street-involved youth age 14-26 at enrollment, and analyzed using generalized estimating equations. Among 505 participants, 142 (28.1%) reported syringe borrowing and 132 (26.1%) reported syringe lending during the study period. In separate multivariable analyses, having difficulty finding clean needles and homelessness were significantly associated with syringe borrowing (Adjusted Odds Ratio (AOR) = 2.28, 95% CI 1.66-3.12 and AOR = 1.52, CI 1.05-2.21, respectively) and syringe lending (AOR = 1.89, 95% CI 1.32-2.71 and AOR = 1.65, 95% CI 1.11-2.44, respectively) (all p values people is warranted.

  5. Low-Cost Touchscreen Driven Programmable Dual Syringe Pump for Life Science Applications

    OpenAIRE

    Liu, Jamin; Garcia, Valentina; Derisi, Joseph

    2018-01-01

    Syringe pumps are powerful tools able to automate routine laboratory practices that otherwise consume large amounts of manual labor time. Commercially available syringe pumps are expensive, difficult to customize, and often preset for a narrow range of operations. Here, we show how to build a programmable dual syringe pump (PDSP) that overcomes these limitations. The PDSP is driven by a Raspberry Pi paired with a stepper motor controller to allow maximal customization via Python scripting. Th...

  6. Aquagenic syringeal acrokeratoderma

    Directory of Open Access Journals (Sweden)

    Belkiz Uyar

    2014-01-01

    Full Text Available Aquagenic syringeal acrokeratoderma is a rare, transient, and usually bilaterally symmetric, palmoplantar keratoderma. Patients complain of tingling and pain in the hands starting a few minutes after exposure to water and lasting for 20-30 minutes after removal. Clinically, there is marked wrinkling with edematous white papules on the palms or, less often, the soles. We present the case of a 21-year-old woman who used spironolactone for polycystic ovary syndrome and had similar clinical features 2 weeks later, after withdrawing the drug.

  7. Study of different filters

    International Nuclear Information System (INIS)

    Cochinal, R.; Rouby, R.

    1959-01-01

    This note first contains a terminology related to filters and to their operation, and then proposes an overview of general characteristics of filters such as load loss with respect to gas rate, efficiency, and clogging with respect to filter pollution. It also indicates standard aerosols which are generally used, how they are dosed, and how efficiency is determined with a standard aerosol. Then, after a presentation of the filtration principle, this note reports the study of several filters: glass wool, filter papers provided by different companies, Teflon foam, English filters, Teflon wool, sintered Teflonite, quartz wool, polyvinyl chloride foam, synthetic filter, sintered bronze. The third part reports the study of some aerosol and dust separators

  8. UV protection filters by dielectric multilayer thin films on Glass BK-7 and Infrasil 301

    International Nuclear Information System (INIS)

    Abdel-Aziz, M.M.; Azim, Osama A.; Abdel-Wahab, L.A.; Seddik, Mohamed M.

    2006-01-01

    The increasing use of Ultraviolet (UV) light in medicine, industrial environments, for cosmetic use, and even in consumer products necessitates that greater attention be paid to the potential hazards of this type of electromagnetic radiation. To avoid any adverse effects of exposure to this type of radiation, four suitable protection filters were produced to block three UV bands (UVA, UVB, and UVC). The design structure of the required dielectric multilayer filters was done by optical thin film technology using the absorbing property of UV radiation for the substrates and dielectric materials. The computer analyses of the multilayer filter formulas were prepared using Macleod Software for the production processes. The deposition technique was achieved on optical substrates (Glass BK-7 and Infrasil 301) by dielectric material combinations including Titanium dioxide (Ti 2 O 3 ), Hafnium dioxide (HfO 2 ), and Lima (mixture of oxides SiO 2 /Al 2 O 3 ); deposition being achieved using an electron beam gun. The output results of the theoretical and experimental transmittance values for spectral band from 200 nm to 800 nm were discussed in four processes. To analyze the suitability for use in 'real world' applications, the test pieces were subjected to the durability tests (adhesion, abrasion resistance, and humidity) according to Military Standard MIL-C-675C and MIL-C-48497A

  9. UV protection filters by dielectric multilayer thin films on Glass BK-7 and Infrasil 301

    Science.gov (United States)

    Abdel-Aziz, M. M.; Azim, Osama A.; Abdel-Wahab, L. A.; Seddik, Mohamed M.

    2006-10-01

    The increasing use of Ultraviolet (UV) light in medicine, industrial environments, for cosmetic use, and even in consumer products necessitates that greater attention be paid to the potential hazards of this type of electromagnetic radiation. To avoid any adverse effects of exposure to this type of radiation, four suitable protection filters were produced to block three UV bands (UVA, UVB, and UVC). The design structure of the required dielectric multilayer filters was done by optical thin film technology using the absorbing property of UV radiation for the substrates and dielectric materials. The computer analyses of the multilayer filter formulas were prepared using Macleod Software for the production processes. The deposition technique was achieved on optical substrates (Glass BK-7 and Infrasil 301) by dielectric material combinations including Titanium dioxide (Ti 2O 3), Hafnium dioxide (HfO 2), and Lima (mixture of oxides SiO 2/Al 2O 3); deposition being achieved using an electron beam gun. The output results of the theoretical and experimental transmittance values for spectral band from 200 nm to 800 nm were discussed in four processes. To analyze the suitability for use in 'real world' applications, the test pieces were subjected to the durability tests (adhesion, abrasion resistance, and humidity) according to Military Standard MIL-C-675C and MIL-C-48497A.

  10. Syringe vending machines for injection drug users: an experiment in Marseille, France.

    Science.gov (United States)

    Obadia, Y; Feroni, I; Perrin, V; Vlahov, D; Moatti, J P

    1999-01-01

    OBJECTIVES: This study evaluated the usefulness of vending machines in providing injection drug users with access to sterile syringes in Marseille, France. METHODS: Self-administered questionnaires were offered to 485 injection drug users obtaining syringes from 32 pharmacies, 4 needle exchange programs, and 3 vending machines. RESULTS: Of the 343 respondents (response rate = 70.7%), 21.3% used the vending machines as their primary source of syringes. Primary users of vending machines were more likely than primary users of other sources to be younger than 30 years, to report no history of drug maintenance treatment, and to report no sharing of needles or injection paraphernalia. CONCLUSIONS: Vending machines may be an appropriate strategy for providing access to syringes for younger injection drug users, who have typically avoided needle exchange programs and pharmacies. PMID:10589315

  11. Over-the-counter but out of reach: a pharmacy-based survey of OTC syringe sales in Tijuana, Mexico.

    Science.gov (United States)

    Pollini, Robin A; Gallardo, Manuel; Ruiz, Serena; Case, Patricia; Zaller, Nickolas; Lozada, Remedios

    2014-05-01

    Sterile syringe access is critical to HIV prevention efforts targeting injection drug users (IDUs) but some pharmacies do not sell syringes over-the-counter (OTC) even where such sales are legal. We conducted a pharmacy survey in Tijuana, Mexico (where OTC sales are legal) to characterize attitudes toward syringe sales and to explore support for expanding pharmacy-based HIV prevention efforts. Of 203 respondents, 28% supported OTC syringe sales to IDUs and 74% said their pharmacy required a prescription for at least some syringe sales. Support for OTC syringe sales was independently associated with selling OTC syringes, understanding the role of sterile syringes in HIV prevention, and recognizing pharmacies as an important health resource for IDUs. Most respondents supported an expanded role for pharmacies in HIV prevention, exclusive of OTC syringe sales. Our study provides information for developing interventions to promote OTC syringe sales and expanding pharmacy-based distribution of HIV-related information and resources.

  12. The benefits and drawbacks of syringe drivers in palliative care.

    Science.gov (United States)

    Costello, John; Nyatanga, Brian; Mula, Carole; Hull, Jenny

    2008-03-01

    This article will outline the use of continuous subcutaneous infusion pumps, known as syringe drivers, including their benefits and drawbacks in a palliative care context. There have been over 5000 articles published globally describing syringe drivers in the medical and nursing literature within the last decade. Many provide guidance on their use, although much of the data are repetitious, disease or age-group specific, and focused on pragmatic issues to do with clinical application. Several trusts and hospices across the UK are carrying out trials of the recently launched McKinley T34 syringe driver. Therefore, it seems timely to consider their wider use internationally. Globally, practitioners in palliative care are very familiar with their use, although the literature lacks specific guidance and, at times, the information is ambiguous. Having briefly reviewed their benefits, the article considers the limitations of using syringe drivers and comments on some of the lesser known/reported practical and patient-focused drawbacks associated with their use. We conclude by considering why, when so much education and training exists to help practitioners use these devices effectively, so many human errors occur.

  13. Reuse prevention syringes for reconstitution of lyophilized vaccines: Operational study and UNICEF plans for expanding introduction.

    Science.gov (United States)

    Fleming, Jessica A; Hoekstra, Edward John; Moniaga, Vanda; Widjaya, Anton; Soepardi, Jane; Supartha, Nyoman; Salovaara, Annika; Khamassi, Selma; Nelson, Carib

    2009-01-01

    Since the 1990s, the United Nation's Children's Fund has encouraged injection safety for immunizations through bundling vaccines with appropriate amounts of supporting equipment and by supplying autodisable (AD) syringes for injections. However, poor vaccine reconstitution practices continue to be reported worldwide. By 2009, UNICEF will begin to phase out the distribution of standard disposable syringes for vaccine reconstitution and replace them with reuse prevention (RUP) syringes, with a full transition expected by the end of 2010. A field evaluation in Indonesia was conducted to identify introduction requirements, issues with healthcare worker training and acceptance, and RUP syringe performance and safety. Managers and health workers felt that RUP syringes improved injection safety and fit easily into country logistical systems. Healthcare workers felt they were intuitive to use, but recommended special training. The integration of RUP reconstitution syringes by UNICEF could increase injection safety by preventing the reuse of syringes and reducing vaccine contamination.

  14. High dead-space syringe use among people who inject drugs in Tijuana, Mexico.

    Science.gov (United States)

    Rafful, Claudia; Zule, William; González-Zúñiga, Patricia E; Werb, Dan; Medina-Mora, María Elena; Magis-Rodriguez, Carlos; Strathdee, Steffanie A

    2015-05-01

    High dead-space syringes (HDSS) are believed to confer an elevated risk of acquiring HIV and other blood-borne infections. We identified prevalence and correlates of HDSS use among injection drug users (IDU) in Tijuana, Mexico, where syringe purchase and possession is legal without a prescription. Beginning in 2011, IDU who reported being 18 years or older and injected drugs within the last month were recruited into a prospective study. At baseline and semi-annually, 557 IDU underwent HIV-testing and interviewer-administered surveys. Logistic regression was used to identify correlates of using HDSS. Of 557 IDU, 40% had ever used HDSS, mostly because no other syringe type was available (72%), or because they were easier to get (20%). Controlling for sex and age at first injection, use of HDSS was associated with cocaine as the first drug injected (Adjusted Odds Ratio [AOR]: 2.68; Confidence Interval 95% [CI]: 1.15-6.22), having been stopped or arrested by police (AOR: 1.84; 95% CI: 1.11-3.07), being deported from the US (AOR: 1.64; 95% CI:1.06-2.53), and believing it is illegal to carry syringes (AOR:1.78; 95% CI: 1.01-3.15). Use of HDSS is surprisingly common among IDU in Tijuana. Efforts are needed to expand coverage of low-dead space syringes through existing syringe exchange programs. Education is required to increase awareness of the harms associated with HDSS, and to inform IDU that syringe possession is legal across Mexico.

  15. An introduction to the Micrel Micropump MP Daily portable syringe driver.

    Science.gov (United States)

    Groves, Karen E

    2003-11-01

    In this article the author describes the Micrel Micropump MP Daily (MP Daily) portable syringe driver. This follows the author's experience of a 4-month pilot of the device by an inpatient palliative care unit. Portable syringe drivers are commonly used to deliver continuous subcutaneous infusions in palliative care situations. Those in current use are not without problems and serious adverse events have occasionally been reported, mainly resulting from confusion between models. The MP Daily syringe driver addresses some of these issues while remaining small, lightweight and inexpensive, with a long battery life and fitting into the pocket of a shirt of pyjama jacket. Improvements over current models include an on/off button, the absence of facilities to set a zero rate or change the rate once the syringe driver is running, and the absence of a boost button. In addition, there are improved alarms, a message display system and a configuration menu. Although confusion remains a problem, and the ideal has not yet been reached, the MP Daily goes some considerable way towards reducing risks and opportunities for human error.

  16. The evaluation of a trial of syringe vending machines in Canberra, Australia.

    Science.gov (United States)

    McDonald, David

    2009-07-01

    Syringe vending machines (SVMs) have been trialled in Canberra, Australian Capital Territory, Australia, as an intervention aiming to increase the availability of sterile injecting equipment for use by IDUs. This study evaluated the 12-month trial. A utilisation-focused evaluation model, with both formative and summative components, was employed. Four SVMs were installed, each dispensing packs containing four 1 mL syringes and associated injecting paraphernalia. The trial participants were the clients of the SVMs and other key informants. The core measurements used were the number of syringes dispensed in Canberra by SVMs and other outlets, SVM clients' demographics and experiences of and attitudes towards SVMs, perceived impacts of SVMs on needle sharing, unsafe disposal of used syringes in the vicinity of SVMs, and community and stakeholder attitudes. The trial was implemented successfully, with no adverse consequences identified. The SVMs appear to be serving both the usual clients of the other outlets for sterile injecting equipment (community pharmacies and the Needle Syringe Program outlets) and others who are reluctant to use such outlets or find them inconvenient. The out-of-business-hours provision of syringes through the SVMs was particularly welcomed by both SVM clients and other stakeholders. The continuing operation of the initial four SVMs is widely supported, and additional machines are requested by clients and others. Owing to the success of the trial in terms of feasibility and outcomes for both IDUs and for the broader community, it is desirable that providing sterile injecting equipment through SVMs continues and be expanded as an integral component of harm reduction strategies.

  17. Influence of Syringe Volume on Foam Stability in Sclerotherapy for Varicose Vein Treatment.

    Science.gov (United States)

    Bai, Taoping; Jiang, Wentao; Fan, Yubo

    2018-05-01

    Despite the popularity of sclerotherapy for treating varicose veins, it still exhibits various problems, such as pulmonary embolism, deep-vein thrombosis, phlebitis, and visual disorders. To investigate syringe volume influence on foam stability, obtain the foam decay rule, and provide a reference for clinics. Five types of syringes are used to prepare foam at room temperature with various liquid-gas ratios. Foam decay process experiments were performed 5 times and recorded by video. The stability indices used include drainage time, half-life, bubble diameter, bubble surface density, and drainage rate. The 30 and 2-mL syringes, respectively, recorded the highest and lowest drainage speeds. Foam drainage time and half-life, differences varied between 15 and 70 seconds, and 20 and 100 seconds, respectively. Foam bubble diameters were distributed over 0.1 to 2.0 mm with roughly 200 to 700 bubbles per square centimeter. Increased syringe volume causes the bubble diameter to increase. Thus, foam dispersion increases and foam half-life decreases; hence, foam becomes unstable. It is, thus, better to use a small syringe several times to prepare foam in clinics using segmented injections.

  18. Large volume syringe pump extruder for desktop 3D printers

    Directory of Open Access Journals (Sweden)

    Kira Pusch

    2018-04-01

    Full Text Available Syringe pump extruders are required for a wide range of 3D printing applications, including bioprinting, embedded printing, and food printing. However, the mass of the syringe becomes a major challenge for most printing platforms, requiring compromises in speed, resolution and/or volume. To address these issues, we have designed a syringe pump large volume extruder (LVE that is compatible with low-cost, open source 3D printers, and herein demonstrate its performance on a PrintrBot Simple Metal. Key aspects of the LVE include: (1 it is open source and compatible with open source hardware and software, making it inexpensive and widely accessible to the 3D printing community, (2 it utilizes a standard 60 mL syringe as its ink reservoir, effectively increasing print volume of the average bioprinter, (3 it is capable of retraction and high speed movements, and (4 it can print fluids using nozzle diameters as small as 100 μm, enabling the printing of complex shapes/objects when used in conjunction with the freeform reversible embedding of suspended hydrogels (FRESH 3D printing method. Printing performance of the LVE is demonstrated by utilizing alginate as a model biomaterial ink to fabricate parametric CAD models and standard calibration objects. Keywords: Additive manufacturing, 3D bioprinting, Embedded printing, FRESH, Soft materials extrusion

  19. Air-assisted dispersive liquid-liquid microextraction based on a new hydrophobic deep eutectic solvent for the preconcentration of benzophenone-type UV filters from aqueous samples.

    Science.gov (United States)

    Ge, Dandan; Zhang, Yi; Dai, Yixiu; Yang, Shumin

    2018-04-01

    Deep eutectic solvents are considered as new and green solvents that can be widely used in analytical chemistry such as microextraction. In the present work, a new dl-menthol-based hydrophobic deep eutectic solvent was synthesized and used as extraction solvents in an air-assisted dispersive liquid-liquid microextraction method for preconcentration and extraction of benzophenone-type UV filters from aqueous samples followed by high-performance liquid chromatography with diode array detection. In an experiment, the deep eutectic solvent formed by dl-menthol and decanoic acid was added to an aqueous solution containing the UV filters, and then the mixture was sucked up and injected five times by using a glass syringe, and a cloudy state was achieved. After extraction, the solution was centrifuged and the upper phase was subjected to high-performance liquid chromatography for analysis. Various parameters such as the type and volume of the deep eutectic solvent, number of pulling, and pushing cycles, solution pH and salt concentration were investigated and optimized. Under the optimum conditions, the developed method exhibited low limits of detection and limits of quantitation, good linearity, and precision. Finally, the proposed method was successfully applied to determine the benzophenone-type filters in environmental water samples with relative recoveries of 88.8-105.9%. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Retraction of the Plunger on a Syringe of Hyaluronic Acid Before Injection: Are We Safe?

    Science.gov (United States)

    Carey, Wayne; Weinkle, Susan

    2015-12-01

    Controversy exists concerning the need for aspiration before injection with hyaluronic acid (HA) fillers. The authors undertook a study of HA products to determine if blood could be aspirated back into a syringe of HA when the needle has been primed or filled with HA. Two studies were set up to determine if or when blood could be withdrawn from a heparinized fresh tube of blood into the HA syringe. Two different techniques were tested; one using a slow-pull retraction of the plunger and up to a 5-second waiting time before release versus a rapid pullback and quick release. Review of these data demonstrates that the usual clinical method, which involves quick withdrawal and instant release of the syringe plunger does not allow for sufficient removal of the filler found intraluminal in the needle and may give rise to false negative results in vitro and likely in vivo with the exception being the Galderma/Medicis products. In summary, withdrawal of the syringe plunger with no visible blood in the syringe does not eliminate the possibility of intravascular placement of the syringe needle.

  1. Adsorption of technetium-99m tetrofosmin and technetium-99m furifosmin on plastic syringes

    International Nuclear Information System (INIS)

    Bartosch, R.; Granegger, S.; Sinzinger, H.

    1998-01-01

    Some groups have reported that adsorption of radiopharmaceuticals on disposable plastic syringes can reach levels of almost 50%. This high loss of radioactivity stimulated us to carry out similar studies. Our measurements were done in combination with patient studies. Therefore, we used 2-ml syringes, all of the same brand. The radioactivity in the syringe was measured immediately before and after injection. a total of 500-600 MBq technetium-99m labelled tetrofosmin or technetium-99m furifosmin was administered to 48 patients using four different injection techniques (n = 6 for each technique with each tracer): with needles, 1 min blood incubation at 22 C, 10 or 30 min after preparation of the tracer; with butterflies, 1 min blood incubation at 22 C, 10 or 30 min after preparation of the tracer. Neither in syringes nor in needles or butterflies did more than 7% of the initial radioactivity remain. The entire residual activity in syringe plus needle or syringe plus butterfly together never exceeded the 9% limit. Furthermore, in a pilot study we measured the remaining radioactivity in the vial; here, too, we found no more than 14% of total radioactivity. These findings indicate that total retention of radioactivity during elution and application of 99m Tc-tetrofosmin and 99m Tc-furifosmin with material used in our setting does not approach relevant amounts. (orig.)

  2. Progress towards the use of disposable filters

    International Nuclear Information System (INIS)

    Macphail, I.

    1979-08-01

    Thermally degradable materials have been evaluated for service in HEPA filter units used to filter gases from active plants. The motivation was to reduce the bulk storage problems of contaminated filters by thermal decomposition to gaseous products and a solid residue substantially comprised of the filtered particulates. It is shown that while there are no commercially available alternatives to the glass fibre used in the filter medium, it would be feasible to manufacture the filter case and spacers from materials which could be incinerated. Operating temperatures, costs and the type of residues for disposal are discussed for filter case materials. (U.K.)

  3. Syringe irrigation: blending endodontics and fluid dynamics

    NARCIS (Netherlands)

    Boutsioukis, C.; van der Sluis, L.W.M.; Basrani, B.

    2015-01-01

    Syringe irrigation remains a widely used irrigant delivery method during root canal treatment. An interdisciplinary approach involving well-established methods from the field of fluid dynamics can provide new insights into the mechanisms involved in cleaning and disinfection of the root canal system

  4. Barriers to Access to Sterile Syringes as Perceived by Pharmacists and Injecting Drug Users: Implications for Harm Reduction in Lebanon.

    Science.gov (United States)

    Ghaddar, Ali; Nassar, Karine; Elsoury, Ghadier

    2017-09-19

    Access to sterile syringes to injecting drug users (IDU) reduces sharing behavior and prevents the transmission of HIV. To describe the barriers to access to sterile syringes for IDUs in Lebanon from the perspectives of pharmacists and IDUs. in this qualitative study conducted in Lebanon, data were collected from 72 syringe purchase tests at pharmacies, 64 interviewees with pharmacists and 2 focus groups with injecting drug users. Two independent researchers analyzed the verbatim transcripts. Results revealed that pharmacists often deny access to sterile syringes to IDUs who are frequently stigmatized and intimidated at pharmacies. While no large gender differences in pharmacists' attitudes and practices were observed, inequalities in syringe access were noticed with men IDUs more often denied purchase. Pharmacists had several barriers to sell syringes to IDUs including fear of disease spread, increased drug use, inappropriately discarded syringes, staff and customer safety, and business concerns. IDUs had several challenges to purchase syringes including stigmatization, intimidation, physical harassment, concern to reveal identity, fear of arrest and syringe price abuse. Identifying the barriers to and facilitators of access to sterile syringes to IDUs is important to guide the development of efficient policies. Findings implicate the importance of empowering IDUs to purchase syringes at pharmacies through reducing the negative attitude towards IDUs and strengthening pharmacists' role in the promotion of health of IDUs. Findings also suggest that the habit of syringe sharing would decrease if the legal and cultural barriers to access are reduced.

  5. Adsorption of technetium-99m tetrofosmin and technetium-99m furifosmin on plastic syringes

    Energy Technology Data Exchange (ETDEWEB)

    Bartosch, R.; Granegger, S.; Sinzinger, H. [Department of Nuclear Medicine, University of Vienna (Austria)

    1998-09-01

    Some groups have reported that adsorption of radiopharmaceuticals on disposable plastic syringes can reach levels of almost 50%. This high loss of radioactivity stimulated us to carry out similar studies. Our measurements were done in combination with patient studies. Therefore, we used 2-ml syringes, all of the same brand. The radioactivity in the syringe was measured immediately before and after injection. a total of 500-600 MBq technetium-99m labelled tetrofosmin or technetium-99m furifosmin was administered to 48 patients using four different injection techniques (n = 6 for each technique with each tracer): with needles, 1 min blood incubation at 22 C, 10 or 30 min after preparation of the tracer; with butterflies, 1 min blood incubation at 22 C, 10 or 30 min after preparation of the tracer. Neither in syringes nor in needles or butterflies did more than 7% of the initial radioactivity remain. The entire residual activity in syringe plus needle or syringe plus butterfly together never exceeded the 9% limit. Furthermore, in a pilot study we measured the remaining radioactivity in the vial; here, too, we found no more than 14% of total radioactivity. These findings indicate that total retention of radioactivity during elution and application of {sup 99m}Tc-tetrofosmin and {sup 99m}Tc-furifosmin with material used in our setting does not approach relevant amounts. (orig.) With 4 figs., 1 tab., 7 refs.

  6. Aspects of syringeal mechanics in avian phonation

    NARCIS (Netherlands)

    Larsen, O.N.; Goller, F.; Leeuwen, van J.L.

    2006-01-01

    The vocal organ of birds, the syrinx, is formed by modified cartilages of the trachea and bronchi. Recently, the use of thin, flexible endoscopes has made direct observation of the syrinx possible in situ. The effects of direct muscle stimulation on the syringeal aperture identified adductor and

  7. Development of acid-resistant HEPA filter components

    International Nuclear Information System (INIS)

    Terada, K.; Woodard, R.W.; Buttedahl, O.I.

    1981-01-01

    Laboratory and in-service tests of various HEPA filter media and separators were conducted to establish their relative resistances to HNO 3 -HF vapors. Filter medium of glass fiber with Nomex additive and aluminum separators with an epoxy-vinyl coating have performed quite well in the acid environment in the laboratory, and in prototype-filters placed in service in a plenum at Rocky Flats. Proprietary filters with new design and/or components were also tested in service with generally good results

  8. A study of uniformity of elements deposition on glass fiber filters after collection of airborne particulate matter (PM-10), using a high-volume sampler.

    Science.gov (United States)

    Marrero, Julieta; Rebagliati, Raúl Jiménez; Gómez, Darío; Smichowski, Patricia

    2005-12-15

    A study was conducted to evaluate the homogeneity of the distribution of metals and metalloids deposited on glass fiber filters collected using a high-volume sampler equipped with a PM-10 sampling head. The airborne particulate matter (APM)-loaded glass fiber filters (with an active surface of about 500cm(2)) were weighed and then each filter was cut in five small discs of 6.5cm of diameter. Each disk was mineralized by acid-assisted microwave (MW) digestion using a mixture of nitric, perchloric and hydrofluoric acids. Analysis was performed by axial view inductively coupled plasma optical emission spectrometry (ICP OES) and the elements considered were: Al, As, Cd, Cr, Cu, Fe, Mn, Ni, Pb, Sb, Ti and V. The validation of the procedure was performed by the analysis of the standard reference material NIST 1648, urban particulate matter. As a way of comparing the possible variability in trace elements distribution in a particular filter, the mean concentration for each element over the five positions (discs) was calculated and each element concentration was normalized to this mean value. Scatter plots of the normalized concentrations were examined for all elements and all sub-samples. We considered that an element was homogeneously distributed if its normalized concentrations in the 45 sub-samples were within +/-15% of the mean value ranging between 0.85 and 1.15. The study demonstrated that the 12 elements tested showed different distribution pattern. Aluminium, Cu and V showed the most homogeneous pattern while Cd and Ni exhibited the largest departures from the mean value in 13 out of the 45 discs analyzed. No preferential deposition was noticed in any sub-sample.

  9. Negotiating access: social barriers to purchasing syringes at pharmacies in Tijuana, Mexico.

    Science.gov (United States)

    Davidson, Peter J; Lozada, Remedios; Rosen, Perth C; Macias, Armando; Gallardo, Manuel; Pollini, Robin A

    2012-07-01

    One common public health response to the emergence of HIV has been the provision of sterile syringes to people who inject drugs. In Mexico specialized syringe exchanges are rare, and the sale of needles through pharmacies is often the only way people who inject drugs can obtain sterile syringes. However, people who inject drugs in Tijuana, Mexico report considerable social barriers to successfully purchasing syringes at pharmacies. Between October 2008 and March 2009 we conducted seven in-depth focus groups with 47 people who inject drugs in Tijuana, Mexico. Focus group transcripts were analysed using a descriptive and thematic approach rooted in grounded theory. We found that injectors offered a number of explanations for why pharmacies were reluctant to sell them syringes, including fear of police; attitudes toward drug use; fear of stereotypical drug user behaviour such as petty theft, violence, or distressing behaviour; and related fears that an obvious drug using clientèle would drive away other customers. Injectors described a range of ways of attempting to re-frame or negotiate interactions with pharmacy staff so that these and related concerns were ameliorated. These included tactics as simple as borrowing cleaner clothing, through to strategies for becoming 'known' to pharmacy staff as an individual rather than as a member of a stigmatized group. Increasing the ability of pharmacy staff and people who inject drugs to successfully negotiate syringe sales are highly desirable. Interventions designed to improve this likelihood need to capitalize on existing solutions developed ad hoc by people who inject drugs and pharmacy staff, and should focus on broadening the range of 'identities' which pharmacy staff are able to accept as legitimate customers. Approaches to achieve this end might include sensitizing pharmacy staff to the needs of people who inject drugs; facilitating individual drug users meeting individual pharmacy staff; and working with drug users

  10. Structure of CdTe nanoparticles in glass

    Science.gov (United States)

    Hayes, T. M.; Nagpal, Swati; Persans, P. D.

    2000-03-01

    Optical long-pass wavelength filters are generally made by growing small crystallites of appropriate semiconductors in a transparent glass matrix. Depending on the semiconductor, these systems are candidates for interesting and important nonlinear optical switching applications. The structure of these nanocrystals has been shown to be a valuable indicator of the chemical and thermodynamic processes during crystallite growth and dissolution. We have used x-ray absorption spectroscopy to study the structure of the crystallites produced during heat treatment of filter glasses containing Cd and Te and producing optical absorption edges at the band gap of bulk CdTe. The results will be discussed.

  11. FULL SCALE REGENERABLE HEPA FILTER DESIGN USING SINTERED METAL FILTER ELEMENTS

    International Nuclear Information System (INIS)

    Gil Ramos; Kenneth Rubow; Ronald Sekellick

    2002-01-01

    A Department of Energy funded contract involved the development of porous metal as a HEPA filter, and the subsequent design of a full-scale regenerable HEPA filtration system (RHFS). This RHFS could replace the glass fiber HEPA filters currently being used on the high level waste (HLW) tank ventilation system with a system that would be moisture tolerant, durable, and cleanable in place. The origins of the contract are a 1996 investigation at the Savannah River Technology Center (SRTC) regarding the use of porous metal as a HEPA filter material. This contract was divided into Phases I, IIA and IIB. Phase I of the contract evaluated simple filter cylinders in a simulated High Level Waste (HLW) environment and the ability to clean and regenerate the filter media after fouling. Upon the successful completion of Phase I, Phase IIA was conducted, which included lab scale prototype testing and design of a full-scale system. The work completed under Phase IIA included development of a full-scale system design, development of a filter media meeting the HEPA filtration efficiency that would also be regenerable using prescribed cleaning procedures, and the testing of a single element system prototype at Savannah River. All contract objectives were met. The filter media selected was a nickel material already under development at Mott, which met the HEPA filtration efficiency standard. The Mott nickel media met and exceeded the HEPA requirement, providing 99.99% removal against a requirement of 99.97%. Double open-ended elements of this media were provided to the Savannah River Test Center for HLW simulation testing in the single element prototype filter. These elements performed well and further demonstrated the practicality of a metallic media regenerable HEPA filter system. An evaluation of the manufacturing method on many elements demonstrated the reproducibility to meet the HEPA filtration requirement. The full-scale design of the Mott RHFS incorporated several important

  12. Syringe Decriminalization Advocacy in Red States: Lessons from the North Carolina Harm Reduction Coalition.

    Science.gov (United States)

    Cloud, David H; Castillo, Tessie; Brinkley-Rubinstein, Lauren; Dubey, Manisha; Childs, Robert

    2018-05-08

    Syringe access programs (SAPs) are cornerstone harm reduction interventions for combatting the national opioid epidemic. The goal of this paper is to describe effective advocacy strategies for enacting syringe decriminalization legislation to foster the expansion of SAPs in high-need areas amidst political opposition. Decades or research shows that SAPs prevent the transmission of HIV among people who inject drugs (PWID) and are a cost-effective tool for linking PWID to medical care, health education, and social services. In the USA, state laws criminalizing distribution and possession of syringes impede the expansion of SAPs into areas where they are sorely needed. In 2016, North Carolina became the first state to legalize SAPs with a Republican super majority. This paper distills strategies for community organizations seeking to advance syringe decriminalization legislation in politically conservative states with histories of prioritizing punitive sanctions over public health responses to drug use.

  13. Homicide by Sch from a syringe-like dart ejected by a compound crossbow.

    Science.gov (United States)

    Guo, Wei; Luo, Guochang; Wang, Hao; Meng, Xiangzhi

    2015-02-01

    The compound crossbow can be used to eject syringe-like dart loaded with poisonous solution. Succinylcholine (Sch) is a short-acting neuromuscular blocker medically used to achieve complete relaxation of muscle for a good intubation condition. Without the help of an artificial respirator, intramuscular injection of a large dose of Sch can paralyze the respiratory muscle and result in the receiver's death. In this paper, we present the homicide case of a young male killed by Sch from a syringe-like dart ejected by a compound crossbow. The subcutaneous and muscular hemorrhages observed around the entry were more severe than that caused by a medical injection. Additionally, other autopsy results showed the external appearance of a pinhole, general asphyxia signs and pathological findings which were not characteristic. The discovery of a syringe-like dart at the scene is the critical clue and reason for analyzing for Sch, which is commonly used to load syringe-like dart to paralyze and steal dog in the countryside of China. Copyright © 2014 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  14. Dump the pump: manual aspiration thrombectomy (MAT) with a syringe is technically effective, expeditious, and cost-efficient.

    Science.gov (United States)

    Gross, Bradley A; Jadhav, Ashutosh P; Jovin, Tudor G; Jankowitz, Brian Thomas

    2018-04-01

    Syringe aspiration for manual aspiration thrombectomy (MAT) is a cost- and time-efficient alternative to an aspiration pump with likely similar efficacy. It is counterintuitive to expect the pump to perform better than direct vacuum with a syringe, as the pump must deliver vacuum additionally through a canister and meters of tubing. To present in vitro and clinical results of MAT with a syringe. An in vitro analysis was performed comparing vacuum pressures generated by syringe aspiration and with pump aspiration. This was then complemented with prospective clinical data providing details of angiographic and clinical outcomes for syringe MAT. The in vitro analysis demonstrated that equal to slightly greater vacuum pressures were generated by a 60 cc syringe as compared with the pump in both static and partial flow conditions. In our clinical series, 106/113 acute stroke thrombectomies over a 6-month period were performed with syringe MAT on the first pass. Syringe usage instead of pump tubing and a canister led to a total savings of $58 300. The rate of Thrombolysis in Cerebral Infarction 2b/3 recanalization was 93%. Adjunctive stentriever usage was performed in 23% of cases. Median puncture to reperfusion time was 25 min; mean change in National Institute of Health Stroke Scale score at 24 hours was an improvement of 5.1 (median 6). The in-hospital mortality rate was 10%. Seventy percent of patients were discharged to home (modified Rankin Scale (mRS) score 0-2) or a rehabilitation facility (mRS score 2-4). MAT using a syringe is a safe, fast, and more cost-effective approach than using an aspiration pump. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. Spatial filters on demand based on aperiodic Photonic Crystals

    Energy Technology Data Exchange (ETDEWEB)

    Gailevicius, Darius; Purlys, Vytautas; Peckus, Martynas; Gadonas, Roaldas [Laser Research Center, Department of Quantum Electronics, Vilnius University (Lithuania); Staliunas, Kestutis [DONLL, Departament de Fisica, Universitat Politecnica de Catalunya (UPC), Terrassa (Spain); Institucio Catalana de Recerca i Estudis Avancats (ICREA), Barcelona (Spain)

    2017-08-15

    Photonic Crystal spatial filters, apart from stand-alone spatial filtering function, can also suppress multi-transverse-mode operation in laser resonators. Here it is shown that such photonic crystals can be designed by solving the inverse problem: for a given spatial filtering profile. Optimized Photonic Crystal filters were fabricated in photosensitive glass. Experiments have shown that such filters provide a more pronounced filtering effect for total and partial transmissivity conditions. (copyright 2017 by WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  16. A syringe-sharing model for the spread of HIV: application to Omsk, Western Siberia.

    Science.gov (United States)

    Artzrouni, Marc; Leonenko, Vasiliy N; Mara, Thierry A

    2017-03-01

    A system of two differential equations is used to model the transmission dynamics of human immunodeficiency virus between 'persons who inject drugs' (PWIDs) and their syringes. Our vector-borne disease model hinges on a metaphorical urn from which PWIDs draw syringes at random which may or may not be infected and may or may not result in one of the two agents becoming infected. The model's parameters are estimated with data mostly from the city of Omsk in Western Siberia. A linear trend in PWID prevalence in Omsk could only be fitted by considering a time-dependent version of the model captured through a secular decrease in the probability that PWIDs decide to share a syringe. A global sensitivity analysis is performed with 14 parameters considered random variables in order to assess their impact on average numbers infected over a 50-year projection. With obvious intervention implications the drug injection rate and the probability of syringe-cleansing are the only parameters whose coefficients of correlations with numbers of infected PWIDs and infected syringes have an absolute value close to or larger than 0.40. © The authors 2015. Published by Oxford University Press on behalf of the Institute of Mathematics and its Applications. All rights reserved.

  17. Sensory source strength of used ventilation filters

    DEFF Research Database (Denmark)

    Clausen, Geo; Alm, Ole Martin; Fanger, Povl Ole

    2002-01-01

    A two-year-old filter was placed in a ventilation system recirculating the air in an experimental space. Via glass tubes supplied with a small fan it was possible to extract air upstream and downstream of the filter to an adjacent room. A panel could thus perform sensory assessments of the air fr...

  18. Investigating Liquid Leak from Pre-Filled Syringes upon Needle Shield Removal: Effect of Air Bubble Pressure.

    Science.gov (United States)

    Chan, Edwin; Maa, Yuh-Fun; Overcashier, David; Hsu, Chung C

    2011-01-01

    This study is to investigate the effect of headspace air pressure in pre-filled syringes on liquid leak (dripping) from the syringe needle upon needle shield removal. Drip tests to measure drip quantity were performed on syringes manually filled with 0.5 or 1.0 mL of various aqueous solutions. Parameters assessed included temperature (filling and test), bulk storage conditions (tank pressure and the type of the pressurized gas), solution composition (pure water, 0.9% sodium chloride, and a monoclonal antibody formulation), and testing procedures. A headspace pressure analyzer was used to verify the drip test method. Results suggested that leakage is indeed caused by headspace pressure increase, and the temperature effect (ideal gas expansion) is a major, but not the only, factor. The dissolved gases in the liquid bulk prior to or during filling may contribute to leakage, as these gases could be released into the headspace due to solubility changes (in response to test temperature and pressure conditions) and cause pressure increase. Needle shield removal procedures were found to cause dripping, but liquid composition played little role. Overall, paying attention to the processing history (pressure and temperature) of the liquid bulk is the key to minimize leakage. The headspace pressure could be reduced by decreasing liquid bulk storage pressure, filling at a higher temperature, or employing lower solubility gas (e.g., helium) for bulk transfer and storage. Leakage could also be mitigated by simply holding the syringe needle pointing upward during needle shield removal. Substantial advances in pre-filled syringe technology development, particularly in syringe filling accuracy, have been made. However, there are factors, as subtle as how the needle shield (or tip cap) is removed, that may affect dosing accuracy. We recently found that upon removal of the tip cap from a syringe held vertically with needle pointed downwards, a small amount of solution, up to 3-4% of

  19. Evaluation and validation of a bee venom sting challenge performed by a micro-syringe.

    Science.gov (United States)

    Cortellini, Gabriele; Severino, Maurizio; Francescato, Elisabetta; Turillazzi, Stefano; Spadolini, Igino; Rogkakou, Anthi; Passalacqua, Giovanni

    2012-12-01

    The honeybee sting challenge is considered a reliable procedure to evaluate the efficacy of specific immunotherapy, but it is difficult and unpractical to perform in clinical practice, because live insects are required. To assess the feasibility and reliability of a challenge test using a micro-syringe, and compared the procedure with sting challenge. Patients on bee venom immunotherapy and without systemic reactions at field sting were enrolled. They underwent a sting challenge with live bee, and large local reactions were assessed up to 48 hours. Those patients displaying systemic reactions at the sting challenge were excluded from the syringe challenge for ethical reasons. The syringe challenge was done by injecting 0.5 μL fresh unfiltered bee venom at 2 mm depth (the length of the sting left by a bee). The same follow-up as at the first challenge was performed. Bee-specific immunoglobulin E (IgE) and tryptase were measured after each challenge. Nineteen patients underwent the sting challenge with live bees. Four had immediate systemic reactions (urticaria or asthma) and were excluded from the second challenge. The remaining 15 patients with large local reaction underwent the syringe challenge. No significant difference was seen in the maximum area of the large local reactions between the challenge with live bees and the syringe challenge. Also, no change was seen in tryptase and specific antibodies. This preliminary study suggests that the micro-syringe challenge with honeybee venom is feasible and produces results indistinguishable from those of the traditional sting challenge. Copyright © 2012 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  20. The measurement of activity in vials and syringes using a radionuclide assay calibrator

    International Nuclear Information System (INIS)

    Hooper, S.A.; Davies, I.H.

    1993-01-01

    To enable accurate measurements of the activity in both vials and syringes, a series of measurements was undertaken to ascertain the changes in response with geometry in nine isotope assay calibrators. From these measurements, two jigs were made for each calibrator to enable (a) optimal measurement of activity in vials and (b) optimal measurement of activity in a variety of syringe sizes. (Author)

  1. The pneumatic syringe: a simple apparatus for self-administration of drugs by rats.

    Science.gov (United States)

    Weeks, J R

    1977-12-01

    Drug solution is delivered by a syringe operated by a pneumatic cylinder. Recommended delivery volumes are from 10 to 200 microliter. A solid-state control unit is described which can operate two syringes (drug injection and flush), has outputs for recording responses and injections, and can be programmed to provide several schedules of reinforcement. All components are readily commercially available.

  2. In-syringe magnetic-stirring-assisted liquid-liquid microextraction for the spectrophotometric determination of Cr(VI) in waters.

    Science.gov (United States)

    Henríquez, Camelia; Horstkotte, Burkhard; Solich, Petr; Cerdà, Víctor

    2013-08-01

    A fully automated method for the determination of chromate is described. It is based on the selective reaction of Cr(VI) with diphenylcarbazide in acidic media to form a colored complex of Cr(III) with the oxidation product diphenylcarbazone. The reaction was performed within the syringe of an automatic burette containing a magnetic stirrer for homogenization of the sample and the required reagents. In-syringe stirring was made possible using a specially designed driving device placed around the syringe barrel to achieve a rotating magnetic field in the syringe, forcing the stirrer to spin. In a second step, the reaction mixture in the syringe was neutralized to allow in-syringe magnetic-stirring-assisted dispersive liquid-liquid microextraction of the complex into 125 μL of n-hexanol. After phase separation by droplet flotation over 30 s, the organic phase was propelled into a coupled spectrophotometric detection cell. The entire multistep procedure including in-system standard preparation was done within 270 s. The method was used for the analysis of natural waters, achieving average analyte recovery of 103%, a limit of detection of 0.26 μg L(-1), and a repeatability of less than 4% relative standard deviation.

  3. Syringe-vacuum microfluidics: A portable technique to create monodisperse emulsions.

    Science.gov (United States)

    Abate, Adam R; Weitz, David A

    2011-03-16

    We present a simple method for creating monodisperse emulsions with microfluidic devices. Unlike conventional approaches that require bulky pumps, control computers, and expertise with device physics to operate devices, our method requires only the microfluidic device and a hand-operated syringe. The fluids needed for the emulsion are loaded into the device inlets, while the syringe is used to create a vacuum at the device outlet; this sucks the fluids through the channels, generating the drops. By controlling the hydrodynamic resistances of the channels using hydrodynamic resistors and valves, we are able to control the properties of the drops. This provides a simple and highly portable method for creating monodisperse emulsions.

  4. Nonprescription naloxone and syringe sales in the midst of opioid overdose and hepatitis C virus epidemics: Massachusetts, 2015.

    Science.gov (United States)

    Stopka, Thomas J; Donahue, Ashley; Hutcheson, Marguerite; Green, Traci C

    To determine the prevalence of nonprescription naloxone and sterile syringe sales, factors associated with nonprescription sales, geospatial access to nonprescription naloxone and syringe-selling pharmacies, and targets for potential interventions. Cross-sectional study. Massachusetts has experienced steep increases in reported opioid overdoses and hepatitis C virus cases in the past decade. Pharmacists have the potential to play a substantial role in increasing access to nonprescription naloxone and sterile syringes, which can reverse opioid overdoses and decrease hepatitis C virus transmission, respectively. We completed brief telephone surveys with 809 of 1042 retail pharmacies across Massachusetts (response rate = 77.6%) during 2015 to assess experience with nonprescription sales of naloxone and sterile syringes. Our primary outcomes were the stocking and selling of naloxone in the pharmacy (yes or no) for nonprescription sales and nonprescription syringe sales (yes or no). We conducted multivariable regression analyses and created maps using a geographic information system to identify factors associated with nonprescription sales of naloxone and sterile syringes, and to improve our understanding of geospatial access to pharmacy-based naloxone and syringe sales. More than 97% of pharmacies reported selling sterile syringes without requiring a prescription, and 45% of pharmacies reported stocking and selling naloxone. Factors associated with nonprescription sales included hours of operation, experience with and interest in harm reduction activities, and presence in an opioid overdose hotspot. Geographic access to nonprescription sale of sterile syringes is widespread, whereas geospatial access to naloxone is limited. Training to understand the benefits, applications, and distribution needs of naloxone is of interest to surveyed pharmacists. Access to sterile syringes through nonprescription sales is strong across Massachusetts, and although more than 350

  5. Nonlinear optical studies in semiconductor-doped glasses under ...

    Indian Academy of Sciences (India)

    Abstract. Nonlinear optical studies in semiconductor-doped glasses (SDGs) are per- formed under femtosecond laser pulse excitation. Z-scan experiments with 800 nm wave- length pulses are used to excite SDG samples in the resonance and non-resonance regimes. Schott colour glass filter OG 515 shows stronger ...

  6. Joule-heated glass-furnace system for the incineration of low-level radioactive wastes

    International Nuclear Information System (INIS)

    Armstrong, K.M.; Klingler, L.M.; Doty, J.W.; Kramer, D.P.

    1982-01-01

    For the past 1-1/2 years, Mound has been preparing and evaluating a commercially available joule-heated glass furnace unit, coupled with a wet scrubbing system. The purpose of the glass furnace evaluation is to advance and document incinerator technology for such combustibles as solids, resins, and sludges, and to develop a stable waste form for subsequent disposal. Four (4) waste nonradioactive types were selected to determine the combustion efficiency of the furnace unit: (1) dry solid waste composed of paper, plastics, rubber, and cloth, (2) ion exchange resin of both the anionic and cationic type, (3) filter sludge composed of diatomaceous earth, organic cellulosic filter aid, and powdered ion exchange resin, and (4) cartridge filters having glass and plastic filter surfaces and nonmetallic cores. When completed, the combustion efficiency experiments for the proposed nonradioactive waste-types revealed the ability of the furnace to easily incinerate waste at feedrates of up to 150 lb/hr. During the course of the experiments, combustibles in the offgas remained consistently low, suggesting excellent combustion efficiency. Furthermore, ash produced by the combustion process was effectively incorporated into the melt by convective currents in the glass. Future work on the glass furnace incinerator will include spiking the waste to determine radioisotope behavior in the furnace

  7. Prefilled syringes for intravitreal injection reduce preparation time

    DEFF Research Database (Denmark)

    Subhi, Yousif; Kjer, Birgit; Munch, Inger Christine

    2016-01-01

    INTRODUCTION: The demand for intravitreal therapy has increased dramatically with the introduction of vascular endo-thelial growth factor inhibitors. Improved utilisation of existing resources is crucial to meeting the increased future demand. We investigated time spent preparing intravitreal inj...... had no influence on the design of the study, analysis of the data, preparation of the manuscript or the decision to publish. TRIAL REGISTRATION: not relevant.......INTRODUCTION: The demand for intravitreal therapy has increased dramatically with the introduction of vascular endo-thelial growth factor inhibitors. Improved utilisation of existing resources is crucial to meeting the increased future demand. We investigated time spent preparing intravitreal...... injection treatment using either prefilled syringes or vials in routine clinical practice. METHODS: We video-recorded preparations of intravitreal injections (n = 172) for each preparation type (ranibizumab prefilled syringe (n = 56), ranibizumab vial (n = 56) and aflibercept vial (n = 60)) in a multi...

  8. Suitability of various materials for porous filters in diffusion experiments

    Energy Technology Data Exchange (ETDEWEB)

    Aldaba, David; Vidal, Miquel; Rigol, Anna [Univ. de Barcelona (Spain). Dept. de Quimica Analitica; Glaus, Martin; Van Loon, Luc [Paul Scherrer Institut, Villigen PSI (Switzerland). Lab. for Waste Management; Leupin, Olivier [Nagra, Wettingen (Switzerland)

    2014-10-01

    The suitability of different porous materials (stainless steel, VYCOR {sup registered} glass, Al{sub 2}O{sub 3} and PEEK) for use as confining filters in diffusion experiments was evaluated by measuring the effective diffusion coefficients (D{sub e}) of neutral (HTO) and ionic solutes (Na{sup +}, Cs{sup +}, Sr{sup 2+}, Cl{sup -}, SeO{sub 4}{sup 2-}) in the materials in through-diffusion experiments. For stainless steel filters, the D{sub e} values of the target solutes correlated satisfactorily with their bulk diffusion coefficient in water (D{sub w}); thus, the diffusion process in the stainless steel filters was primarily controlled by the diffusivity of the solvated ions. For the remaining materials, the D{sub e} and D{sub w} values were also correlated for the target solutes, and the geometric factors were in the sequence: VYCOR {sup registered} glass < Al{sub 2}O{sub 3} < PEEK. Stainless steel and VYCOR {sup registered} glass were the most appropriate materials because of their high D{sub e} values, but a specific interaction of caesium with VYCOR {sup registered} glass was hypothesised because the D{sub e} values obtained for this solute were slightly higher than expected.

  9. Microbial contamination of syringes during preparation: the direct influence of environmental cleanliness and risk manipulations on end-product quality.

    Science.gov (United States)

    Stucki, Cyril; Sautter, Anna-Maria; Favet, Jocelyne; Bonnabry, Pascal

    2009-11-15

    The direct influence of environmental cleanliness and risk manipulations on prepared syringes was evaluated. Media-fill testing was used to estimate potential microbial contamination. Syringes were prepared in three different environments using four different uncontrolled high-risk manipulations. The three environments included an International Organization for Standardization (ISO) class 5 horizontal laminar-airflow hood in an ISO class 6 cleanroom (in accordance with United States Pharmacopeia [USP] chapter 797), an ISO class 7 drug preparation area of an operating room, and an uncontrolled decentralized pharmacy in a ward. For each combination of environment and manipulation, 100 syringes were filled by a single operator. The four high-risk manipulations used included simple filling of syringes with trypticase soy broth, three-second contact by the ungloved fingers of the operator with the hub of the syringe, three-second contact between an object and the hub of the syringe, and exposure of the filled syringes to ambient air for 10 minutes. Of the 1500 syringes prepared in three different environments, none produced within the cleanroom contained microorganisms, 6% were contaminated in the operating room, and 16% were contaminated in the ward (p ISO class 5 cleanroom in accordance with USP chapter 797 requirements was demonstrated to be the best way to avoid bacterial or fungal contamination of injectable drugs directly resulting in patient infections.

  10. Neutron diffraction studies of glasses

    International Nuclear Information System (INIS)

    Wright, A.C.

    1987-01-01

    A survey is given of the application of neutron diffraction to structural studies of oxide and halide glasses. As with crystalline materials, neutron and X-ray diffraction are the major structural probes for glasses and other amorphous solids, particularly in respect of intermediate range order. The glasses discussed mostly have structures which are dominated by a network in which the bonding is predominantly covalent. The examples discussed demonstrate the power of the neutron diffraction technique in the investigation of the structures of inorganic glasses. The best modern diffraction experiments are capable of providing accurate data with high real space resolution, which if used correctly, are an extremely fine filter for the various structural models proposed in the literature. 42 refs

  11. Legal syringe purchases by injection drug users, Brooklyn and Queens, New York City, 2000-2001.

    Science.gov (United States)

    Des Jarlais, Don C; McKnight, Courtney; Friedmann, Patricia

    2002-01-01

    To assess preliminary results of the Expanded Syringe Access Demonstration Program (ESAP) in New York City. Temporal trends of pharmacy use among injection drug users (IDUs) in Brooklyn and Queens were analyzed from December 2000 through December 2001. Brooklyn and Queens, New York City. PARTIPANTS: IDUs. Attempts to purchase syringes from pharmacies and success in doing so. Of the 1,072 IDUs interviewed from December 2000 through December 2001, the majority were daily heroin injectors, but there was also substantial speedball and cocaine injection. There was a clear increase over time in both the percentage of subjects who attempted to purchase syringes in pharmacies and in the percentage who successfully purchased syringes. Among IDUs interviewed 4 or more months after ESAP began, large majorities of those who attempted to purchase syringes were successful in doing so. No differences in use of ESAP by IDUs were identified in Brooklyn versus Queens: 27% of IDUs interviewed in Queens reported that they had attempted to purchase syringes in pharmacies versus 28% in Brooklyn. Persons who reported injecting on a daily or more frequent basis were more likely to have attempted pharmacy purchases than persons who reported injecting less frequently, 32% versus 21%. The ESAP program has led to an increase in the use of pharmacies as sources of sterile injection equipment among IDUs in New York City. The extent to which pharmacies become an important source of sterile injection equipment and the effect of legal pharmacy sales on risk behaviors for human immunodeficiency virus (HIV) infection remain to be determined.

  12. Low melting high lithia glass compositions and methods

    Science.gov (United States)

    Jantzen, Carol M.; Pickett, John B.; Cicero-Herman, Connie A.; Marra, James C.

    2000-01-01

    The invention relates to methods of vitrifying waste and for lowering the melting point of glass forming systems by including lithia formers in the glass forming composition in significant amounts, typically from about 0.16 wt % to about 11 wt %, based on the total glass forming oxides. The lithia is typically included as a replacement for alkali oxide glass formers that would normally be present in a particular glass forming system. Replacement can occur on a mole percent or weight percent basis, and typically results in a composition wherein lithia forms about 10 wt % to about 100 wt % of the alkali oxide glass formers present in the composition. The present invention also relates to the high lithia glass compositions formed by these methods. The invention is useful for stabilization of numerous types of waste materials, including aqueous waste streams, sludge solids, mixtures of aqueous supernate and sludge solids, combinations of spent filter aids from waste water treatment and waste sludges, supernate alone, incinerator ash, incinerator offgas blowdown, or combinations thereof, geological mine tailings and sludges, asbestos, inorganic filter media, cement waste forms in need of remediation, spent or partially spent ion exchange resins or zeolites, contaminated soils, lead paint, etc. The decrease in melting point achieved by the present invention desirably prevents volatilization of hazardous or radioactive species during vitrification.

  13. Decreased Odds of Injection Risk Behavior Associated With Direct Versus Indirect Use of Syringe Exchange: Evidence From Two California Cities.

    Science.gov (United States)

    Behrends, Czarina N; Li, Chin-Shang; Gibson, David R

    2017-07-29

    While there is substantial evidence that syringe exchange programs (SEPs) are effective in preventing HIV among people who inject drugs (PWID), nearly all the evidence comes from PWID who obtain syringes from an SEP directly. Much less is known about the benefits of secondary exchange to PWID who get syringes indirectly from friends or acquaintances who visit an SEP for them. We evaluated the effectiveness of direct versus indirect syringe exchange in reducing HIV-related high-risk injecting behavior among PWID in two separate studies conducted in Sacramento and San Jose, California, cities with quite different syringe exchange models. In both studies associations between direct and indirect syringe exchange and self-reported risk behavior were examined with multivariable logistic regression models. Study 1 assessed effects of a "satellite" home-delivery syringe exchange in Sacramento, while Study 2 evaluated a conventional fixed-site exchange in San Jose. Multivariable analyses revealed 95% and 69% reductions, respectively, in high-risk injection associated with direct use of the SEPs in Sacramento and San Jose, and a 46% reduction associated with indirect use of the SEP in Sacramento. Conclusions/Importance: The very large effect of direct SEP use in Sacramento was likely due in part to home delivery of sterile syringes. While more modest effects were associated with indirect use, such use nevertheless is valuable in reducing the risk of HIV transmission of PWID who are unable or unwilling to visit a syringe exchange.

  14. Making a difference? Applying Vitellone's Social Science of the Syringe to performance and image enhancing drug injecting.

    Science.gov (United States)

    Hart, Aaron

    2018-04-18

    Vitellone's Social Science of the Syringe investigates epistemologies of injecting drug use. She argues for a methodology that can be simultaneously sensitive to biopolitical power regimes; the trajectories of social stratification; and the resistance, creativity and dignity of human agency. She proposes a methodological focus on the syringe-in-use as an active participant in these dynamics. Harm reduction policy and service provision frameworks have paid little attention to the phenomena of performance and image enhancing drug (PIEDs) injection. One way of assessing the merit of Vitellone's proposal is to use it to investigate these phenomena. I argue that Vitellone's method can be used to articulate a range of significant differences between people who inject PIEDs and other people who inject drugs, and that these differences can inform harm reduction initiatives. When compared to the heroin syringe, the PIED syringe participates in different socio-economic and material contexts, gendered identities, and biopolitical governance regimes. These differences materialise in different rates of syringe sharing and blood-borne virus transmission; and different experiences of needle exchange services. I offer a thought experiment demonstrating how a different syringe might alter the structural dynamics, biopolitical governance, and the agentic choices of people who inject PIEDs. Judging by the productive effects of diffracting Vitellone's analysis through an empirical concern with PIED injecting, I concur with Vitellone's proposition that 'something objective may be gained from an empirical investigation of the syringe-in-use' (p. 33). Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Study of different filters; Etude de differents filtres

    Energy Technology Data Exchange (ETDEWEB)

    Cochinal, R.; Rouby, R.

    1959-07-01

    This note first contains a terminology related to filters and to their operation, and then proposes an overview of general characteristics of filters such as load loss with respect to gas rate, efficiency, and clogging with respect to filter pollution. It also indicates standard aerosols which are generally used, how they are dosed, and how efficiency is determined with a standard aerosol. Then, after a presentation of the filtration principle, this note reports the study of several filters: glass wool, filter papers provided by different companies, Teflon foam, English filters, Teflon wool, sintered Teflonite, quartz wool, polyvinyl chloride foam, synthetic filter, sintered bronze. The third part reports the study of some aerosol and dust separators.

  16. Sharing of Needles and Syringes among Men Who Inject Drugs: HIV Risk in Northwest Bangladesh.

    Directory of Open Access Journals (Sweden)

    M Kamal Pasa

    Full Text Available Injection drug use is prevalent in northwestern Bangladesh. We sought to explore the context of needle/syringe sharing among persons who inject drugs (PWID, examining risk exposures to blood-borne infections like the human immunodeficiency virus (HIV and hepatitis in a region where these dual epidemics are likely to expand.We used a qualitative research approach to learn about injection practices, conducting 60 in-depth interviews among PWID. We then conducted 12 focus group discussions (FGDs that generated a checklist of salient issues, and followed up with personal observations of typical days at the drug-use venues. Content and interpretative frameworks were used to analyze qualitative information and socio-demographic information, using SPSS software.We found that needle/syringe-sharing behaviours were integrated into the overall social and cultural lives of drug users. Sharing behaviours were an central component of PWID social organization. Sharing was perceived as an inherent element within reciprocal relationships, and sharing was tied to beliefs about drug effects, economic adversity, and harassment due to their drug user status. Carrying used needles/syringes to drug-use venues was deemed essential since user-unfriendly needle-syringe distribution schedules of harm reduction programmes made it difficult to access clean needles/syringes in off-hours. PWID had low self-esteem. Unequal power relationships were reported between the field workers of harm reduction programmes and PWID. Field workers expressed anti-PWID bias and judgmental attitudes, and also had had misconceptions about HIV and hepatitis transmission. PWID were especially disturbed that no assistance was forthcoming from risk reduction programme staff when drug users manifested withdrawal symptoms.Interventions must take social context into account when scaling up programmes in diverse settings. The social organization of PWID include values that foster needle-syringe

  17. A study of gross morphological and histological syringeal features of ...

    African Journals Online (AJOL)

    A study of gross morphological and histological syringeal features of true francolins (Galliformes: Francolinus, Scleroptila, Peliperdix and Dendroperdix spp.) and spurfowls ( Pternistis spp.) in a phylogenetic context.

  18. Stability of erythropoietin repackaging in polypropylene syringes for clinical use

    Directory of Open Access Journals (Sweden)

    Angela Marsili

    2017-02-01

    Full Text Available Introduction: Epoetin alfa (Eprex® is a subcutaneous, injectable formulation of short half-life recombinant human erythropoietin (rHuEPO. To current knowledge there are no published studies regarding the stability of rHuEPO once repackaging occurs (r-EPO for clinical trial purposes. Materials and methods: We assessed EPO concentration in Eprex® and r-EPO syringes at 0, 60, 90, and 120 days after repackaging in polypropylene syringes. R-EPO was administered to 56 patients taking part in a clinical trial in Friedreich Ataxia. Serum EPO levels were measured at baseline and 48 h after r-EPO administration. Results: No differences were found between r-EPO and Eprex® syringes, but both globally decreased in total EPO content during storage at 4 °C. Patients receiving r-EPO had similar levels in EPO content as expected from previous trials in Friedreich Ataxia and from pharmacokinetics studies in healthy volunteers. Discussion: We demonstrate that repackaging of EPO does not alter its concentration if compared to the original product (Eprex®. This is true both for repackaging procedures and for the stability in polypropylene tubes. The expiration date of r-EPO can be extended from 1 to 4 months after repackaging, in accordance with pharmacopeia rules.

  19. Investigation of Two Prototypes of Novel Noncontact Technologies for Automated Real-Time Capture of Incremental Drug Administration Data From Syringes.

    Science.gov (United States)

    Eagle, Benjamin; Williams, David J; Dingley, John

    2017-08-01

    An ideal electronic anesthesia recording system would be capable of not only recording physiological data but also injectable drug doses given, including those given incrementally from one syringe, without recourse to manual data entry. We compared 2 prototype devices which wirelessly recognized individual syringes and measured changes in their plunger positions via 2 different optical noncontact means, allowing calculation of incremental drug doses given. Both devices incorporated a radio-frequency identification reader, which wirelessly read a unique code from a radio-frequency identification tag within syringe drug labels. A custom-designed cradle oriented any inserted 1-mL to 20-mL syringe in a repeatable position. The "laser" device had a moving laser beam broken by the end of the syringe plunger. The infrared (IR) device measured time of travel of IR light from a sender to a syringe plunger and back to a receiver. Both devices could therefore determine the drug and volume administered since the previous occasion when any syringe had been used. For each syringe size of 1, 2, 5, 10, and 20 mL, 121 plunger-length measurements were made over their full range, with each machine against a reference method of water filling and weighing using a randomized de Bruijn sequence. For every syringe size, the laser device showed greater accuracy and precision, lower bias, and narrower limits of agreement (95% confidence intervals = bias ± 1.96 SD) than the IR device when compared to the reference method. For all syringe sizes, the range of bias was -0.05 to 0.32 mL for the laser and -2.42 to 1.38 mL for the IR. Lin concordance correlation coefficient values for the IR versus reference methods ranged from 0.6259 to 0.9255, with the lowest coefficients seen in syringes with the shortest distance of plunger travel (2 and 5 mL), while in laser versus reference comparisons, these coefficients were similar (0.9641-0.9981) over all syringe lengths. Both devices measured syringe

  20. In Situ Cleanable Alternative HEPA Filter Media

    International Nuclear Information System (INIS)

    Adamson, D. J.; Terry, M. T.

    2002-01-01

    The Westinghouse Savannah River Company, located at the Savannah River Site in Aiken, South Carolina, is currently testing two types of filter media for possible deployment as in situ regenerable/cleanable High Efficiency Particulate Air (HEPA) filters. The filters are being investigated to replace conventional, disposable, glass-fiber, HEPA filters that require frequent removal, replacement, and disposal. This is not only costly and subjects site personnel to radiation exposure, but adds to the ever-growing waste disposal problem. The types of filter media being tested, as part of a National Energy Technology Laboratory procurement, are sintered nickel metal and ceramic monolith membrane. These media were subjected to a hostile environment to simulate conditions that challenge the high-level waste tank ventilation systems. The environment promoted rapid filter plugging to maximize the number of filter loading/cleaning cycles that would occur in a specified period of time. The filters were challenged using nonradioactive simulated high-level waste materials and atmospheric dust; materials that cause filter pluggage in the field. The filters are cleaned in situ using an aqueous solution. The study found that both filter media were insensitive to high humidity or moisture conditions and were easily cleaned in situ. The filters regenerated to approximately clean filter status even after numerous plugging and in situ cleaning cycles. Air Techniques International is conducting particle retention testing on the filter media at the Oak Ridge Filter Test Facility. The filters are challenged using 0.3-mm di-octyl phthalate particles. Both the ceramic and sintered media have a particle retention efficiency > 99.97%. The sintered metal and ceramic filters not only can be cleaned in situ, but also hold great potential as a long life alternative to conventional HEPA filters. The Defense Nuclear Facility Safety Board Technical Report, ''HEPA Filters Used in the Department of

  1. Potential air contamination during CO2 angiography using a hand-held syringe: theoretical considerations and gas chromatography.

    Science.gov (United States)

    Cho, David R; Cho, Kyung J; Hawkins, Irvin F

    2006-01-01

    To assess air contamination in the hand-held syringes currently used for CO2 delivery and to determine whether there is an association between their position and the rate of air contamination. Assessment of air contamination in the syringe (20 ml) included theoretical modeling, mathematical calculation, and gas chromatography (GC). The model was used with Fick's first law to calculate the diffusion of CO2 and the amount of air contamination. For GC studies, the syringes were placed in the upright, horizontal, and inverted positions and gas samples were obtained after 5, 10, 20, 30, and 60 min. All trials with each position for each sampling time were performed five times. The amounts of air contamination with time calculated mathematically were 5-10% less than those of GC. With the diffusivity of air-CO2 at 0.1599 cm2/sec (9.594 cm2/min), air contamination was calculated to be 60% at 60 min. With GC air contamination was 13% at 5 min, 31% at 20 min, 43% at 30 min, and 68% at 60 min. There was no difference in air contamination between the different syringe positions. Air contamination occurs in hand-held syringes filled with CO2 when they are open to the ambient air. The amounts of air contamination over time are similar among syringes placed in the upright, horizontal, and inverted positions.

  2. Photostability of cosmetic UV filters on mammalian skin under UV exposure.

    Science.gov (United States)

    Stiefel, Constanze; Schwack, Wolfgang; Nguyen, Yen-Thi Hai

    2015-01-01

    Previous studies showed that the common UV filter substances benzophenone-3 (BP-3), butyl methoxydibenzoylmethane (BM-DBM), octocrylene (OCR), ethylhexyl methoxycinnamate (EHMC), ethylhexyl salicylate (EHS) and ethylhexyl triazone (EHT) were able to react with amino side chains of different proteins in vitro. To transfer the results to mammalian skin conditions, sunscreen products were applied on both prepared fresh porcine skin and glass plates, followed by UV irradiation and the determination of depletion of the respective UV filters. Significantly lower recoveries of the UV filters extracted from skin samples than from glass plates indicated the additional reaction of the UV filters with skin constituents, when proteins will be the most important reactants. Among the products tested, BP-3 showed the greatest differences in recoveries between glass and skin samples of about 13% and 24% after 2 and 4 h of irradiation, respectively, followed by EHS > BM-DBM > OCR > EHMC > EHT. The obtained results raise the question, whether the common in vitro evaluations of sunscreens, using inert substrate materials like roughened quartz or polymethyl methacrylate (PMMA) plates are really suitable to fully replace in vivo methods, as they cannot include skin-typical reactions. © 2014 The American Society of Photobiology.

  3. Detection of irradiated foods with the photo-stimulated luminescence technique. Selection of a glass fiber filter for evaluating the performance of the PSL detectors

    International Nuclear Information System (INIS)

    Sekiguchi, Masayuki; Yamazaki, Masao; Goto, Michiko

    2008-01-01

    The PSL method is useful as a screening technique of irradiated foods to support efficient uses of TL analysis. Recently, there has been the growing need for the system check or calibration using the standard materials with spread of domestically -produced PSL detector. In this research, we characterized the PSL of several types of glass fiber filters and compared the cumulate photon counts of a selected filter of them (GA-100) with those of the SUERC paprika standard for PSL measurements. GA-100 filter showed a linear relationship between cumulate photon counts and irradiation doses, and the cumulate photon counts in the first 2 months after gamma rays irradiation (261Gy) were markedly decreased and reduced to about 5000 counts (the upper threshold of PSL) after 4 months. However, further long-term storage and dose increase was necessary to produce the filter with more adequate PSI property as a standard material. Light exposure (630Lux) within 3 minutes to GA-100 had little effect on the cumulate photon counts. GA-100 showed relatively less variation in cumulate photon counts compared with the paprika standard in a series of studies. (author)

  4. In-syringe extraction using dissolvable layered double hydroxide-polymer sponges templated from hierarchically porous coordination polymers.

    Science.gov (United States)

    Ghani, Milad; Frizzarin, Rejane M; Maya, Fernando; Cerdà, Víctor

    2016-07-01

    Herein we report the use of cobalt porous coordination polymers (PCP) as intermediates to prepare advanced extraction media based on layered double hydroxides (LDH) supported on melamine polymer foam. The obtained dissolvable Ni-Co LDH composite sponges can be molded and used as sorbent for the in-syringe solid-phase extraction (SPE) of phenolic acids from fruit juices. The proposed sorbent is obtained due to the surfactant-assisted self-assembly of Co(II)/imidazolate PCPs on commercially available melamine foam, followed by the in situ conversion of the PCP into the final dissolvable LDH coating. Advantageous features for SPE are obtained by using PCPs with hierarchical porosity (HPCPs). The LDH-sponge prepared using intermediate HPCPs (HLDH-sponge) is placed in the headspace of a glass syringe, enabling flow-through extraction followed by analyte elution by the dissolution of the LDH coating in acidic conditions. Three phenolic acids (gallic acid, p-hydroxybenzoic acid and caffeic acid) were extracted and quantified using high performance liquid chromatography. Using a 5mL sample volume, the obtained detection limits were 0.15-0.35μgL(-1). The proposed method for the preparation of HLDH-sponges showed a good reproducibility as observed from the intra- and inter-day RSD's, which were <10% for all analytes. The batch-to-batch reproducibility for three different batches of HLDH-sponges was 10.6-11.2%. Enrichment factors of 15-21 were obtained. The HLDH-sponges were applied satisfactorily to the determination of phenolic acids in natural and commercial fruit juices, obtaining relative recoveries among 89.7-95.3%. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Study of loading/air back-pulse cleaning cycles on the performance of ceramic membrane filters

    International Nuclear Information System (INIS)

    Waggoner, Charles; Alderman, Steven; Parsons, Michael; Hogoncamp, Kristina; Alderman, Steven

    2007-01-01

    Available in abstract form only. Full text of publication follows: The most commonly identified threats to conventional glass fiber HEPA filter performance are moisture and rapid blinding of filters by smoke. Regenerable filter media composed of ceramics or sintered metal can be utilized as pre-filters to protect the more vulnerable glass fiber HEPA filters in the event of upset conditions. Additionally, used in a pre-filtering application, the use of these regenerable filters can potentially extend the lifetime of conventional units. A series of tests have been conducted using CeraMem ceramic membrane filters in an effort to evaluate their performance after repeated loading and air back pulse cleaning. This was done in an effort to access filter performance after repeated loading/cleaning cycles. The filters were loaded using a solid potassium chloride aerosol challenge. The filters were evaluated for pressure drop and filtering efficiency changes from one cleaning cycle to the next. Additionally, the particle size distribution of the aerosol penetrating the filters was measured. (authors)

  6. Autologous fat grafting: use of closed syringe microcannula system for enhanced autologous structural grafting

    Directory of Open Access Journals (Sweden)

    Alexander RW

    2013-04-01

    Full Text Available Robert W Alexander,1 David Harrell2 1Department of Surgery, School of Medicine and Dentistry, University of Washington, Seattle, WA, USA; 2Harvest-Terumo Inc, Plymouth, MA, USA Objectives: Provide background for use of acquiring autologous adipose tissue as a tissue graft and source of adult progenitor cells for use in cosmetic plastic surgery. Discuss the background and mechanisms of action of closed syringe vacuum lipoaspiration, with emphasis on accessing adipose-derived mesenchymal/stromal cells and the stromal vascular fraction (SVF for use in aesthetic, structural reconstruction and regenerative applications. Explain a proven protocol for acquiring high-quality autologous fat grafts (AFG with use of disposable, microcannula systems. Design: Explain the components and advantage of use of the patented super luer-lock and microcannulas system for use with the closed-syringe system. A sequential explanation of equipment selection for minimally traumatic lipoaspiration in small volumes is presented, including use of blunt injection cannulas to reduce risk of embolism. Results: Thousands of AFG have proven safe and efficacious for lipoaspiration techniques for large and small structural fat grafting procedures. The importance and advantages of gentle harvesting of the adipose tissue complex has become very clear in the past 5 years. The closed-syringe system offers a minimally invasive, gentle system with which to mobilize subdermal fat tissues in a suspension form. Resulting total nuclear counting of undifferentiated cells of the adipose-derived -SVF suggests that the yield achieved is better than use of always-on, constant mechanical pump applied vacuum systems. Conclusion: Use of a closed-syringe lipoaspiration system featuring disposable microcannulas offers a safe and effective means of harvesting small volumes of nonmanipulated adipose tissues and its accompanying progenitor cells within the SVF. Closed syringes and microcannulas are

  7. High efficiency steel filters for nuclear air cleaning

    International Nuclear Information System (INIS)

    Bergman, W.; Conner, J.; Larsen, G.; Lopez, R.; Turner, C.; Vahla, G.; Violet, C.; Williams, K.

    1991-01-01

    The authors have, in cooperation with industry, developed high-efficiency filters made from sintered stainless-steel fibers for use in several air-cleaning applications in the nuclear industry. These filters were developed to overcome the failure modes in present high-efficiently particulate air (HEPA) filters. HEPA filters are made from glass paper and glue, and they may fail when they get hot or wet and when they are overpressured. In developing steel filters, they first evaluated the commercially available stainless-steel filter media made from sintered powder and sintered fiber. The sintered-fiber media performed much better than sintered-powder media, and the best media had the smallest fiber diameter. Using the best media, prototype filters were then built for venting compressed gases and evaluated in their automated filter tester

  8. Apparatus for Removing Remaining Adhesives of Filter

    International Nuclear Information System (INIS)

    Kang, Il Sik; Kim, Tae Kuk; Hong, Dae Seok; Ji, Young Yong; Ryu, Woo Seog

    2010-01-01

    A Large amount of ventilation filter was used at radiation areas not only in nuclear power plants but also in nuclear facilities. These spent ventilation filters are generated as radioactive waste and composed of a steel frame, glass fiber media and aluminum separator. When treated, the spent filter is separated into filter media for air purification and frame. After separation, while the filter media is collected using steel drum for reducing internal exposure, the filter frame is treated further to remove adhesives for recycling the frame as many as possible in order to reduce waste and cost and improve working conditions. Usually, the adhesives are separated from the filter frame manually. As a result, a lot of time and labor is required. So, the objective of this study is to develop a motor-driven apparatus for removing adhesives efficiently

  9. The use of laboratory sand, soil and crushed-glass filter columns for polishing domestic-strength synthetic wastewater that has undergone secondary treatment.

    Science.gov (United States)

    Healy, M G; Burke, P; Rodgers, M

    2010-10-01

    The aim of this study was to examine the performance of intermittently loaded, 150 mm-diameter stratified filter columns of 2 depths (0.65 and 0.375 m) comprising different media--sand, crushed glass and soil--in polishing the effluent from a laboratory horizontal flow biofilm reactor (HFBR) treating synthetic domestic-strength wastewater. The HFBR has been successfully used to remove organic carbon and ammonium-nitrogen (NH4-N) from domestic wastewater. In this treatment method, wastewater is allowed to flow over and back along a stack of polyvinyl chloride (PVC) sheets. Biofilms on the sheets reduce organic carbon, suspended matter, and nutrients in the wastewater, but to achieve the quality of a septic tank system, additional treatment is required. In all filters, at a hydraulic loading rate of 100 L m(-2) d(-1), 40-65% of chemical oxygen demand (COD) and practically 100% of total suspended solids (TSS) were removed, nitrification was complete, and bacterial numbers were reduced by over 80%, with best removals achieved in the soil filters (93%). Soil polishing filters with the depth of 0.65 m performed best in terms of organic carbon, total nitrogen (Tot-N) and bacterial removal. Data from this preliminary study are useful in the design of treatment systems to polish secondary wastewaters with similar water quality characteristics.

  10. Determination of HEPA Filter Efficiency With Diocthyl Pthalate Aerosol

    International Nuclear Information System (INIS)

    Bunawas; Ruslanto, P O; Suhariyono, G

    1996-01-01

    Ultrafine aerosol filtration by HEPA (High Efficiency Particulate Air) filter has been determinated experimentally, based on the measurement of monodisperse Diocthyl Pthalate (DOP) aerosol concentration before and after passing the test filter. Using this technique, filter efficiency can be determined as a function of aerosol diameter with range from 0.017 to 0.747 um. The average efficiencies for Whatman -41 ; Whatman -42 and Whatman GF/A filters were 56.14 %; 95,74 %; and 99.65 % respectively. Gelman A Fiber Glass and Whatman membrane filter have fulfilled criterion as HEPA filter according to standard of IAEA, because of their minimum effiency of 99.90 %

  11. Potential Air Contamination During CO2 Angiography Using a Hand-Held Syringe: Theoretical Considerations and Gas Chromatography

    International Nuclear Information System (INIS)

    Cho, David R.; Cho, Kyung J.; Hawkins, Irvin F.

    2006-01-01

    Purpose. To assess air contamination in the hand-held syringes currently used for CO 2 delivery and to determine whether there is an association between their position and the rate of air contamination. Methods. Assessment of air contamination in the syringe (20 ml) included theoretical modeling, mathematical calculation, and gas chromatography (GC). The model was used with Fick's first law to calculate the diffusion of CO 2 and the amount of air contamination. For GC studies, the syringes were placed in the upright, horizontal, and inverted positions and gas samples were obtained after 5, 10, 20, 30, and 60 min. All trials with each position for each sampling time were performed five times. Results. The amounts of air contamination with time calculated mathematically were 5-10% less than those of GC. With the diffusivity of air-CO 2 at 0.1599 cm 2 /sec (9.594 cm 2 /min), air contamination was calculated to be 60% at 60 min. With GC air contamination was 13% at 5 min, 31% at 20 min, 43% at 30 min, and 68% at 60 min. There was no difference in air contamination between the different syringe positions. Conclusion. Air contamination occurs in hand-held syringes filled with CO 2 when they are open to the ambient air. The amounts of air contamination over time are similar among syringes placed in the upright, horizontal, and inverted positions

  12. Effects of humidity and filter material on diffusive sampling of isocyanates using reagent-coated filters

    NARCIS (Netherlands)

    Henneken, H.; Vogel, M.; Karst, U.

    2006-01-01

    Diffusive sampling of methyl isocyanate (MIC) on 4-nitro-7-piperazinobenzo-2-oxa-1,3-diazole (NBDPZ)-coated glass fibre (GF) filters is strongly affected by high relative humidity (RH) conditions. It is shown that the humidity interference is a physical phenomenon, based on displacement of reagent

  13. Low pressure chemical vapour deposition of temperature resistant colour filters

    International Nuclear Information System (INIS)

    Verheijen, J.; Bongaerts, P.; Verspui, G.

    1987-01-01

    The possibility to deposit multilayer colour filters, based on optical inference, by means of Low Pressure Chemical Vapour Deposition (LPCVD) was investigated. The filters were made in a standard LPCVD system by alternate deposition of Si/sub 3/N/sub 4/ and SiO/sub 2/ layers. This resulted in filters with excellent colour uniformity on glass and quartz substrates. No difference was measured between theoretically calculated transmission and the transmission of the filters deposited by LPCVD. Temperature treatment at 600 0 C in air air showed no deterioration of filter quality and optical properties

  14. The filter of choice: filtration method preference among injecting drug users

    Directory of Open Access Journals (Sweden)

    Keijzer Lenneke

    2011-08-01

    Full Text Available Abstract Background Injection drug use syringe filters (IDUSF are designed to prevent several complications related to the injection of drugs. Due to their small pore size, their use can reduce the solution's insoluble particle content and thus diminish the prevalence of phlebitis, talcosis.... Their low drug retention discourages from filter reuse and sharing and can thus prevent viral and microbial infections. In France, drug users have access to sterile cotton filters for 15 years and to an IDUSF (the Sterifilt® for 5 years. This study was set up to explore the factors influencing filter preference amongst injecting drug users. Methods Quantitative and qualitative data were gathered through 241 questionnaires and the participation of 23 people in focus groups. Results Factors found to significantly influence filter preference were duration and frequency of injecting drug use, the type of drugs injected and subculture. Furthermore, IDU's rationale for the preference of one type of filter over others was explored. It was found that filter preference depends on perceived health benefits (reduced harms, prevention of vein damage, protection of injection sites, drug retention (low retention: better high, protective mechanism against the reuse of filters; high retention: filter reuse as a protective mechanism against withdrawal, technical and practical issues (filter clogging, ease of use, time needed to prepare an injection and believes (the conviction that a clear solution contains less active compound. Conclusion It was concluded that the factors influencing filter preference are in favour of change; a shift towards the use of more efficient filters can be made through increased availability, information and demonstrations.

  15. Syringe needle-based sampling coupled with liquid-phase extraction for determination of the three-dimensional distribution of l-ascorbic acid in apples.

    Science.gov (United States)

    Tang, Sheng; Lee, Hian Kee

    2016-05-15

    A novel syringe needle-based sampling approach coupled with liquid-phase extraction (NBS-LPE) was developed and applied to the extraction of l-ascorbic acid (AsA) in apple. In NBS-LPE, only a small amount of apple flesh (ca. 10mg) was sampled directly using a syringe needle and placed in a glass insert for liquid extraction of AsA by 80 μL oxalic acid-acetic acid. The extract was then directly analyzed by liquid chromatography. This new procedure is simple, convenient, almost organic solvent free, and causes far less damage to the fruit. To demonstrate the applicability of NBS-LPE, AsA levels at different sampling points in a single apple were determined to reveal the spatial distribution of the analyte in a three-dimensional model. The results also showed that this method had good sensitivity (limit of detection of 0.0097 mg/100g; limit of quantification of 0.0323 mg/100g), acceptable reproducibility (relative standard deviation of 5.01% (n=6)), a wide linear range of between 0.05 and 50mg/100g, and good linearity (r(2)=0.9921). This interesting extraction technique and modeling approach can be used to measure and monitor a wide range of compounds in various parts of different soft-matrix fruits and vegetables, including single specimens. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. The impact of citrate introduction at UK syringe exchange programmes: a retrospective cohort study in Cheshire and Merseyside, UK

    Directory of Open Access Journals (Sweden)

    Wareing Michelle

    2007-12-01

    Full Text Available Abstract Background In 2003, it became legal in the UK for syringe exchange programmes (SEPs to provide citrate to injecting drug users to solubilise heroin. Little work has been undertaken on the effect of policy change on SEP function. Here, we examine whether the introduction of citrate in Cheshire and Merseyside SEPs has altered the number of heroin/crack injectors accessing SEPs, the frequency at which heroin/crack injectors visited SEPs and the number of syringes dispensed. Methods Eleven SEPs in Cheshire and Merseyside commenced citrate provision in 2003. SEP-specific data for the six months before and six months after citrate was introduced were extracted from routine monitoring systems relating to heroin and crack injectors. Analyses compared all individuals attending pre and post citrate and matched analyses only those individuals attending in both periods (defined as 'longitudinal attenders'. Non-parametric tests were used throughout. Results Neither new (first seen in either six months period nor established clients visited SEPs more frequently post citrate. New clients collected significantly less syringes per visit post citrate, than pre citrate (14.5,10.0; z = 1.992, P Conclusion The introduction of citrate did not negatively affect SEP attendance. 'Longitudinal attenders' visited SEPs more frequently post citrate, providing staff with greater opportunity for intervention and referral. As the number of syringes they collected each visit remained unchanged the total number of clean syringes made available to this group of injectors increased very slightly between the pre and post citrate periods. However, new clients collected significantly less syringes post citrate than pre citrate, possibly due to staff concerns regarding the amount of citrate (and thus syringes to dispense safely to new clients. These concerns should not be allowed to negatively impact on the number of syringes dispensed.

  17. Container Closure Integrity Testing of Prefilled Syringes.

    Science.gov (United States)

    Peláez, Sarah S; Mahler, Hanns-Christian; Matter, Anja; Koulov, Atanas; Singh, Satish K; Germershaus, Oliver; Mathaes, Roman

    2018-04-04

    Prefilled syringes (PFSs) are increasingly preferred over vials as container closure systems (CCSs) for injectable drug products when facilitated or self-administration is required. However, PFSs are more complex compared to CCSs consisting of vial, rubber stopper and crimp cap. Container closure integrity (CCI) assurance and verification has been a specific challenge for PFSs as they feature several sealing areas. A comprehensive understanding of the CCS is necessary for an appropriate CCI assessment as well as for packaging development and qualification. A comprehensive CCI assessment of six different PFSs from three different manufacturers (including one polymeric PFS) was conducted using helium leak testing. PFS components were manipulated to systematically assess the contribution of the different sealing areas to CCI, namely rigid needle shield (RNS)/needle, RNS/tip cone and the individual ribs of a syringe plunger. The polymeric PFS required an equilibrium measurement for accurate CCIT. The different sealing areas and a single plunger rib were shown to provide adequate CCI. Acceptable tip cap movement until the point of CCI failure was estimated. The assessment of acceptable tip cap movement demonstrated the importance of considering the RNS/tip cone seal design to ensure CCI of the PFS upon post assembly possesses and shipment. Copyright © 2018. Published by Elsevier Inc.

  18. Drugs given by a syringe driver: a prospective multicentre survey of palliative care services in the UK.

    Science.gov (United States)

    Wilcock, Andrew; Jacob, Jayin K; Charlesworth, Sarah; Harris, Elayne; Gibbs, Margaret; Allsop, Helen

    2006-10-01

    The use of a syringe driver to administer drugs by continuous subcutaneous infusion is common practice in the UK. Over time, drug combinations used in a syringe driver are likely to change and the aim of this survey was to obtain a more recent snapshot of practice. On four separate days, at two-week intervals, a questionnaire was completed for every syringe driver in use by 15 palliative care services. Of 336 syringe drivers, the majority contained either two or three drugs, but one-fifth contained only one drug. The median (range) volume of the infusions was 15 (9.5-48) mL, and duration of infusion was generally 24 hours. Only one combination was reported as visually incompatible, and there were 13 site reactions (4% of total). Laboratory physical and chemical compatibility data are available for less than half of the most frequently used combinations.

  19. UV Blocking Glass: Low Cost Filters for Visible Light Photocatalytic Assessment

    OpenAIRE

    Dunnill, Charles W.

    2014-01-01

    A number of commercially available art protection products have been compared and assessed for their suitability as UV blocking filters in the application of “visible light” photocatalytic research. Many groups claiming visible light photocatalytic success employ filters to block out stray UV radiation in order to justify that their photocatalysts are indeed visible light photocatalysts and not UV light photocatalysts. These filters come in varying degrees of ability and price and many author...

  20. Absolute air filtering equipment in the nuclear industrie. Design - Safety - Experience

    International Nuclear Information System (INIS)

    Lucas, J.C.

    1977-01-01

    The problems encountered in the design of absolute filters (HEPA FILTERS) are presented: glass-fibre filter papers; standards and characteristics: efficiency, fire-resistance, humidity-resistance, radiation-resistance, etc; various types of paper folding: deep folds and small folds, dihedrally mounted; filtering elements; designs; characteristics and quality control; The design of filtration equipment is also analysed: mounting in metal or concrete casings. French and American designs (Regulatory Guide 1-52); and gas-tight casings allowing contaminated filters to be renewed without breaking the gas-tight seal

  1. CONTAMINATION OF ANTI-VEGF DRUGS FOR INTRAVITREAL INJECTION: How Do Repackaging and Newly Developed Syringes Affect the Amount of Silicone Oil Droplets and Protein Aggregates?

    Science.gov (United States)

    Schargus, Marc; Werner, Benjamin P; Geerling, Gerd; Winter, Gerhard

    2017-08-21

    The particle counts and the nature of particles of three different antivascular endothelial growth factor agents (VEGF) in different containers in a laboratory setting were compared. Original prefilled ranibizumab glass syringes, original vials with aflibercept, and repacked ready-to-use plastic syringes with bevacizumab from a compounding pharmacy and a compounding company (CC) were analyzed. Particle counts and size distributions were quantified by different particle characterization methods (nephelometry, light obscuration, Micro-Flow Imaging, nanotracking analysis, resonant mass measurement). Using high-performance size-exclusion chromatography (HP-SEC), levels of protein drug monomer and soluble aggregates were determined. Nearly all samples showed similar product quality. Light obscuration and Micro-Flow Imaging showed a 4-fold to 9-fold higher total particle count in compounding company bevacizumab (other samples up to 42,000 particles/mL). Nanotracking analysis revealed highest values for compounding company bevacizumab (6,375 million particles/mL). All containers showed similar amounts of silicone oil microdroplets. Ranibizumab showed lowest particle count of all tested agents with only one monomer peak in HP-SEC. Repackaged bevacizumab from different suppliers showed varying product quality. All three tested agents are available in similar quality regarding particulate purity and silicone oil microdroplet count. Repackaging can have a major impact on the quality.

  2. The high efficiency steel filters for nuclear air cleaning

    International Nuclear Information System (INIS)

    Bergman, W.; Larsen, G.; Lopez, R.; Williams, K.; Violet, C.

    1990-08-01

    We have, in cooperation with industry, developed high-efficiency filters made from sintered stainless-steel fibers for use in several air-cleaning applications in the nuclear industry. These filters were developed to overcome the failure modes in present high-efficiency particulate air (HEPA) filters. HEPA filters are made from glass paper and glue, and they may fail when they get hot or wet and when they are overpressured. In developing our steel filters, we first evaluated the commercially available stainless-steel filter media made from sintered powder and sintered fiber. The sintered-fiber media performed much better than sintered-powder media, and the best media had the smallest fiber diameter. Using the best media, we then built prototype filters for venting compressed gases and evaluated them in our automated filter tester. 12 refs., 20 figs

  3. PIXE analysis of atmospheric particulate matter in glas fibre filters

    International Nuclear Information System (INIS)

    Tabacniks, M.H.; Orsini, C.Q.; Maenhaut, W.

    1993-01-01

    A 3-step extraction procedure was developed to allow particle-induced X-ray emission (PIXE) analysis of particulate matter in normal glass fibre filter samples. The detection limits, expressed in ng/m 3 of air, for the filter extracts were 5 to 30 times lower than those achieved by PIXE analysis or ordinary Nuclepore polycarbonate filter samples. The concentration results were compared with those obtained from routine atomic absorption spectrometry measurements and with the PIXE data from Nuclepore stacked filter unit samples taken in parallel. (orig.)

  4. Syringe confiscation as an HIV risk factor: the public health implications of arbitrary policing in Tijuana and Ciudad Juarez, Mexico.

    Science.gov (United States)

    Beletsky, Leo; Lozada, Remedios; Gaines, Tommi; Abramovitz, Daniela; Staines, Hugo; Vera, Alicia; Rangel, Gudelia; Arredondo, Jaime; Strathdee, Steffanie A

    2013-04-01

    Female sex workers who inject drugs (FSW-IDUs) face elevated risk for HIV/STIs and constitute a key population for public health prevention. Through direct and indirect pathways including human rights violations, policing practices like syringe confiscation can compound FSW-IDU health risk and facilitate the spread of disease. We studied correlates of experiencing syringe confiscation among FSW-IDUs in northern Mexico, where formal policy allows for syringes to be available over the counter without a prescription, but police practices are often at odds with the law. FSW-IDUs reporting recent syringe sharing and unprotected sex with clients in Tijuana and Ciudad Juarez were administered surveys and HIV/STI testing. Logistic regression was used to identify correlates of syringe confiscation. Among 624 respondent FSW-IDUs, prevalence of syringe confiscation in the last 6 months was 48%. The following factors were positively associated with syringe confiscation: testing positive for HIV (adjusted odds ratio [aOR] = 2.54, 95% confidence interval [CI] = 1.11-5.80), reporting sexual abuse by police (aOR = 12.76, 95% CI = 6.58-24.72), engaging in groin injection (aOR = 1.84, 95% CI = 1.15-2.93), injecting in public (aOR = 1.64; 95% CI = 1.14-2.36), and obtaining syringes from pharmacies (aOR = 1.54; 95% CI = 1.06-2.23). Higher education level was negatively associated with syringe confiscation (aOR = 0.92, 95% CI = 0.87-0.98) as was frequent injection with clients within the last month (aOR = 0.64, 95% CI = 0.44-0.94). This analysis adds to the body of evidence linking unauthorized law enforcement actions targeting high-risk groups with HIV and other adverse health outcomes. Using a public health lens to conceptualize abuse as a structural risk factor, we advocate for multi-prong prevention, systematic monitoring, and evidence-based intervention response to deleterious police practices.

  5. Comparing charcoal and zeolite reflection filters for volatile anaesthetics: A laboratory evaluation.

    Science.gov (United States)

    Sturesson, Louise W; Frennström, Jan O; Ilardi, Marcella; Reinstrup, Peter

    2015-08-01

    A modified heat-moisture exchanger that incorporates a reflecting filter for use with partial rebreathing of exhaled volatile anaesthetics has been commercially available since the 1990 s. The main advantages of the device are efficient delivery of inhaled sedation to intensive care patients and reduced anaesthetic consumption during anaesthesia. However, elevated arterial CO2 values have been observed with an anaesthetic conserving device compared with a conventional heat and moisture exchanger, despite compensation for larger apparatus dead space. The objective of this study is to thoroughly explore the properties of two reflecting materials (charcoal and zeolites). A controlled, prospective, observational laboratory study. Lund University Hospital, Sweden, from December 2011 to December 2012. None. Three filters, with identical volumes, were compared using different volatile anaesthetics at different conditions of temperature and moisture. The filtering materials were charcoal or zeolite. Glass spheres were used as an inert control. Consumption of volatile anaesthetics using different reflecting materials in filters at different conditions regarding temperature and moisture. CO2 reflection by the filtering materials: glass spheres, charcoal or zeolite. Isoflurane consumption in an open system was 60.8 g h(-1). The isoflurane consumption in dry, warm air was 39.8 g h(-1) with glass spheres. Changing to charcoal and zeolite had a profound effect on isoflurane consumption, 11.8 and 10.7 g h(-1), respectively. Heating and humidifying the air as well as the addition of N2O created only minor changes in consumption. The percentage of isoflurane conserved by the charcoal filter was independent of the isoflurane concentration (0.5 to 4.5%). Reflection of sevoflurane, desflurane and halothane by the charcoal filter was similar to reflection of isoflurane. Both charcoal and zeolite filters had CO2 reflecting properties and end-tidal CO2 increased by 3 to 3.7% compared

  6. Community Impact of Pharmacy-Randomized Intervention to Improve Access to Syringes and Services for Injection Drug Users

    Science.gov (United States)

    Crawford, Natalie D.; Amesty, Silvia; Rivera, Alexis V.; Harripersaud, Katherine; Turner, Alezandria; Fuller, Crystal M.

    2014-01-01

    Objectives: In an effort to reduce HIV transmission among injection drug users (IDUs), New York State deregulated pharmacy syringe sales in 2001 through the Expanded Syringe Access Program by removing the requirement of a prescription. With evidence suggesting pharmacists' ability to expand their public health role, a structural, pharmacy-based…

  7. Glass-ceramics: Their production from wastes - a review

    Energy Technology Data Exchange (ETDEWEB)

    Rawlings, R.D.; Wu, J.P.; Boccaccini, A.R. [University of London, London (United Kingdom). Imperial College of Science & Technology, Dept. of Medicine

    2006-02-15

    Glass-ceramics are polycrystalline materials of fine microstructure that are produced by the controlled crystallisation (devitrification) of a glass. Numerous silicate based wastes, such as coal combustion ash, slag from steel production, fly ash and filter dusts from waste incinerators, mud from metal hydrometallurgy, different types of sludge as well as glass cullet or mixtures of them have been considered for the production of glass-ceramics. Developments of glass-ceramics from waste using different processing methods are described comprehensively in this review, covering R&D work carried out worldwide in the last 40 years. Properties and applications of the different glass-ceramics produced are discussed. The review reveals that considerable knowledge and expertise has been accumulated on the process of transformation of silicate waste into useful glass-ceramic products. These glass-ceramics are attractive as building materials for usage as construction and architectural components or for other specialised technical applications requiring a combination of suitable thermo-mechanical properties. Previous attempts to commercialise glass-ceramics from waste and to scale-up production for industrial exploitation are also discussed.

  8. Methods of vitrifying waste with low melting high lithia glass compositions

    Science.gov (United States)

    Jantzen, Carol M.; Pickett, John B.; Cicero-Herman, Connie A.; Marra, James C.

    2001-01-01

    The invention relates to methods of vitrifying waste and for lowering the melting point of glass forming systems by including lithia formers in the glass forming composition in significant amounts, typically from about 0.16 wt % to about 11 wt %, based on the total glass forming oxides. The lithia is typically included as a replacement for alkali oxide glass formers that would normally be present in a particular glass forming system. Replacement can occur on a mole percent or weight percent basis, and typically results in a composition wherein lithia forms about 10 wt % to about 100 wt % of the alkali oxide glass formers present in the composition. The present invention also relates to the high lithia glass compositions formed by these methods. The invention is useful for stabilization of numerous types of waste materials, including aqueous waste streams, sludge solids, mixtures of aqueous supernate and sludge solids, combinations of spent filter aids from waste water treatment and waste sludges, supernate alone, incinerator ash, incinerator offgas blowdown, or combinations thereof, geological mine tailings and sludges, asbestos, inorganic filter media, cement waste forms in need of remediation, spent or partially spent ion exchange resins or zeolites, contaminated soils, lead paint, etc. The decrease in melting point achieved by the present invention desirably prevents volatilization of hazardous or radioactive species during vitrification.

  9. Social-structural contexts of needle and syringe sharing behaviours of HIV-positive injecting drug users in Manipur, India: a mixed methods investigation

    Directory of Open Access Journals (Sweden)

    Shunmugam Murali

    2011-05-01

    Full Text Available Abstract Background Few investigations have assessed risk behaviours and social-structural contexts of risk among injecting drug users (IDUs in Northeast India, where injecting drug use is the major route of HIV transmission. Investigations of risk environments are needed to inform development of effective risk reduction interventions. Methods This mixed methods study of HIV-positive IDUs in Manipur included a structured survey (n = 75, two focus groups (n = 17, seven in-depth interviews, and two key informant interviews. Results One-third of survey participants reported having shared a needle/syringe in the past 30 days; among these, all the men and about one-third of the women did so with persons of unknown HIV serostatus. A variety of social-structural contextual factors influenced individual risk behaviours: barriers to carrying sterile needles/syringes due to fear of harassment by police and "anti-drug" organizations; lack of sterile needles/syringes in drug dealers' locales; limited access to pharmacy-sold needles/syringes; inadequate coverage by needle and syringe programmes (NSPs; non-availability of sterile needles/syringes in prisons; and withdrawal symptoms superseding concern for health. Some HIV-positive IDUs who shared needles/syringes reported adopting risk reduction strategies: being the 'last receiver' of needles/syringes and not a 'giver;' sharing only with other IDUs they knew to be HIV-positive; and, when a 'giver,' asking other IDUs to wash used needles/syringes with bleach before using. Conclusions Effective HIV prevention and care programmes for IDUs in Northeast India may hinge on several enabling contexts: supportive government policy on harm reduction programmes, including in prisons; an end to harassment by the police, army, and anti-drug groups, with education of these entities regarding harm reduction, creation of partnerships with the public health sector, and accountability to government policies that protect IDUs

  10. Wet water glass production plant

    Directory of Open Access Journals (Sweden)

    Stanković Mirjana S.

    2003-01-01

    Full Text Available The IGPC Engineering Department designed basic projects for a wet hydrate dissolution plant, using technology developed in the IGPC laboratories. Several projects were completed: technological, machine, electrical, automation. On the basis of these projects, a production plant of a capacity of 75,000 t/y was manufactured, at "Zeolite Mira", Mira (VE, Italy, in 1997. and 1998, increasing detergent zeolite production, from 50,000 to 100,000 t/y. Several goals were realized by designing a wet hydrate dissolution plant. The main goal was increasing the detergent zeolite production. The technological cycle of NaOH was closed, and no effluents emitted, and there is no pollution (except for the filter cake. The wet water glass production process is fully automatized, and the product has uniform quality. The production process can be controlled manually, which is necessary during start - up, and repairs. By installing additional process equipment (centrifugal pumps and heat exchangers technological bottlenecks were overcome, and by adjusting the operation of autoclaves, and water glass filters and also by optimizing the capacities of process equipment.

  11. Analysis of event logs from syringe pumps: a retrospective pilot study to assess possible effects of syringe pumps on safety in a university hospital critical care unit in Germany.

    Science.gov (United States)

    Kastrup, Marc; Balzer, Felix; Volk, Thomas; Spies, Claudia

    2012-07-01

    Medication errors occur in approximately one out of five doses in a typical hospital setting. Patients in the intensive care unit (ICU) are particularly susceptible to errors during the application of intravenous drugs as they receive numerous potent drugs applied by syringe pumps. The aim of this study was to analyse the effects on potential harmful medication errors and to address factors that have potential for improving medication safety after the introduction of a standardized drug library into syringe pumps with integrated decision support systems. A team of physicians and nurses developed a dataset that defined standardized drug concentrations, application rates and alert limits to prevent accidental overdosing of intravenous medications. This dataset was implemented in 100 syringe pumps with the ability to log programming errors, alerts, reprogramming events and overrides ('smart pumps'). In this retrospective pilot study, all pump-related transaction data were obtained from the pump logs, by downloading the data from the pumps, covering 20 months of use between 1 April 2008 and 30 November 2009. Patient data were gathered from the electronic patient charts. The study was performed in a cardiothoracic ICU of the Charité University Hospital, Berlin, Germany. A total of 7884 patient treatment days and 133,601 infusion starts were evaluated. The drug library with the features of the dose rate was used in 92.8% of the syringe pump starts, in 1.5% of the starts a manual dosing mode without the use of the drug library was used and in 5.7% of the starts the mode 'mL/h', without any calculation features, was used. The most frequently used drugs were vasoactive drugs, followed by sedation medication. The user was alerted for a potentially harmful overdosing in 717 cases and in 66 cases the pumps were reprogrammed after the alert. During the early morning hours a higher rate of alarms was generated by the pumps, compared with the rest of the day. Syringe pumps with

  12. Comparison between syringe irrigation and RinsEndo in reduction of Enterococcus faecalis in experimentally infected root canal

    Directory of Open Access Journals (Sweden)

    Sharareh Mousavi Zahed

    2015-05-01

    Full Text Available Background and Aims: To ensure root canal treatment success, endodontic microbiota should be efficiently reduced. Several irrigation devices have been recently introduced with the main objective of improving root canal disinfection.The purpose of this study was to evaluate the rinsing effect of RinsEndo system in reduction of enterococcus faecalis in comparison with conventional hand syringe in infected root canals.   Materials and Methods: 60 extracted single canal anterior teeth were infected with enterococcus faecalis and divided into 3 groups: RinsEndo system, conventional hand syringe and control group. The enterococcus faecalis colonies were counted in each group before and after rinsing. Data were analyzed using Variance and Kruskal Wallis test.   Results: The mean of enterococcus faecalis growth after rinsing was 3.50×103 in group with conventional syring rinsing, 2.04×103 in group with RinsEndo washing and 6.11×103 in control group. Reduction of enterococcus faecalis after rinsing was statistically significant in each group (P<0.001. The amount of reduction in number of colonies with RinsEndo and conventional syringe rinsing was higher in comparison with control group and this difference was significant (P<0.001. RinsEndo rinsing effect was statistically significantly higher in comparison to conventional syringe as well (P<0.001.   Conclusion: Rinsing with RinsEndo system was significantly more efficient in reduction of enterococcus faecalis from root canal in comparison with hand syringe washing.

  13. Identification of colloids in nuclear waste glass reactions

    International Nuclear Information System (INIS)

    Cunnane, J.C.; Bates, J.K.

    1991-01-01

    Characterization data for particulates formed under a variety of laboratory leaching conditions that simulate glass reaction in a repository environment are presented. Data on the particle size distributions and filterable fractions for neptunium, plutonium, americium, and curium were obtained by filtrations through a series of filters with pore sizes ranging from 1 μm to 3.8 nm. The neptunium was found to be largely nonfilterable. Americium and plutonium were associated with filterable particles. The particles with which the americium, plutonium, and curium were associated were characterized using transmission electron microscopy (TEM) examination techniques. 8 refs., 1 fig., 2 tabs

  14. Iloprost infusion by a new device as a portable syringe pump: safety, tolerability and agreement

    Directory of Open Access Journals (Sweden)

    Paola Faggioli

    2012-12-01

    Full Text Available Background Iloprost, prostacyclin (PGI2 analogue, effective in treatment of peripheral arterial disease, secondary Raynaud's phenomenon (RP to connective tissue disease (CTD, vasculitis, pulmonary hypertension, is usually infused through peristaltic pump, or recently through a flow regulator.Materials and methods We tested a new portable syringe pump (Pompa Infonde®, Italfarmaco S.p.A., Cinisello Balsamo, Milano on 120 patients affected by RP to CTD and cryoglobulinaemia, in iloprost therapy with a flow regulator.Results Iloprost infused through portable syringe pump is better tolerated, better appreciated by the patients and nurses and no difference was observed on therapeutic effects, with a lower incidence of side effects statistically significant. Only 3 patients were unable to tolerate the device (2 for changes in pressure and 1 for fear and shifted to traditional method of iloprost infusion.Conclusions Iloprost infusion through the portable syringe Pompa Infonde® appears to be safe, better tolerated, more acceptable and equally effective compared to infusion through a flow regulator.

  15. Feasibility of Using Fluorescence Spectrophotometry to Develop a Sensitive Dye Immersion Method for Container Closure Integrity Testing of Prefilled Syringes.

    Science.gov (United States)

    Lu, Xujin; Lloyd, David K; Klohr, Steven E

    2016-01-01

    A feasibility study was conducted for a sensitive and robust dye immersion method for the measurement of container closure integrity of unopened prefilled syringes using fluorescence spectrophotometry as the detection method. A Varian Cary Eclipse spectrofluorometer was used with a custom-made sample holder to position the intact syringe in the sample compartment for fluorescence measurements. Methylene blue solution was initially evaluated as the fluorophore in a syringe with excitation at 607 nm and emission at 682 nm, which generated a limit of detection of 0.05 μg/mL. Further studies were conducted using rhodamine 123, a dye with stronger fluorescence. Using 480 nm excitation and 525 nm emission, the dye in the syringe could be easily detected at levels as low as 0.001 μg/mL. The relative standard deviation for 10 measurements of a sample of 0.005 μg/mL (with repositioning of the syringe after each measurement) was less than 1.1%. A number of operational parameters were optimized, including the photomultiplier tube voltage, excitation, and emission slit widths. The specificity of the testing was challenged by using marketed drug products and a protein sample, which showed no interference to the rhodamine detection. Results obtained from this study demonstrated that using rhodamine 123 for container closure integrity testing with in-situ (in-syringe) fluorescence measurements significantly enhanced the sensitivity and robustness of the testing and effectively overcame limitations of the traditional methylene blue method with visual or UV-visible absorption detection. Ensuring container closure integrity of injectable pharmaceutical products is necessary to maintain quality throughout the shelf life of a sterile drug product. Container closure integrity testing has routinely been used to evaluate closure integrity during product development and production line qualification of prefilled syringes, vials, and devices. However, container closure integrity testing

  16. Social network-related risk factors for bloodborne virus infections among injection drug users receiving syringes through secondary exchange.

    Science.gov (United States)

    De, Prithwish; Cox, Joseph; Boivin, Jean-François; Platt, Robert W; Jolly, Ann M

    2008-01-01

    Secondary syringe exchange (SSE) refers to the exchange of sterile syringes between injection drug users (IDUs). To date there has been limited examination of SSE in relation to the social networks of IDUs. This study aimed to identify characteristics of drug injecting networks associated with the receipt of syringes through SSE. Active IDUs were recruited from syringe exchange and methadone treatment programs in Montreal, Canada, between April 2004 and January 2005. Information on each participant and on their drug-injecting networks was elicited using a structured, interviewer-administered questionnaire. Subjects' network characteristics were examined in relation to SSE using regression models with generalized estimating equations. Of 218 participants, 126 were SSE recipients with 186 IDUs in their injecting networks. The 92 non-recipients reported 188 network IDUs. Networks of SSE recipients and non-recipients were similar with regard to network size and demographics of network members. In multivariate analyses adjusted for age and gender, SSE recipients were more likely than non-recipients to self-report being HIV-positive (OR=3.56 [1.54-8.23]); require or provide help with injecting (OR=3.74 [2.01-6.95]); have a social network member who is a sexual partner (OR=1.90 [1.11-3.24]), who currently attends a syringe exchange or methadone program (OR=2.33 [1.16-4.70]), injects daily (OR=1.77 [1.11-2.84]), and shares syringes with the subject (OR=2.24 [1.13-4.46]). SSE is associated with several injection-related risk factors that could be used to help focus public health interventions for risk reduction. Since SSE offers an opportunity for the dissemination of important prevention messages, SSE-based networks should be used to improve public health interventions. This approach can optimize the benefits of SSE while minimizing the potential risks associated with the practice of secondary exchange.

  17. Costs of a Hospital-Based, Ready-To-Use Syringe Delivery Programme

    DEFF Research Database (Denmark)

    Risør, Bettina Wulff; Vand, S; Lisby, M

    2017-01-01

    %) and at €20,905 (an increase of 228%) for the endoscopy department. The ready-to-use delivery program imposed an additional cost of €11.32 per day surgery operation and €2.41 per endoscopy procedure. Conclusion: This ready-to-use programme increased the cost of the medical handling process. This incremental......Objective: The risk of errors in the medication administration process is high. Applications of pre lled syringes may improve patient safety but could be more costly. The objective of this study was to assess the additional costs of a ready-to-use syringe delivery programme in comparison...... with a conventional delivery programme at day surgery and endoscopy departments at a large university hospital. Methods: The cost analysis used the hospital perspective and developed an “activity-based costing” model to assess the costs of medicine- handling activities. The model was calibrated with six-month data...

  18. Smoke filtration in the glass industry. Thomson Videoglass` global approach with closed loop recycling; Fitration des fumees dans l`industrie du verre. L`approche globale avec recyclage en boucle fermee de thomson videoglass

    Energy Technology Data Exchange (ETDEWEB)

    Mocek, L. [Thomson Videoglass, 77 - Bagneaux-sur-Loing (France)

    1996-12-31

    Thomson Videoglass, an ISO 9002 certified manufacturer of glass components for Tv sets in France, has introduced a global closed-loop recycling dust filtration system for glass kilns; electrostatic filters and bag filters (for the lead-containing flat glass kiln) have been selected and collected dusts are recycled in the cone glass kiln. Energy savings, operating conditions, investment and operating costs are discussed together with filter corrosion, clogging-up and service life issues and dust extraction performances

  19. Determining serum bicarbonate; a simple syringe titrator and colorimeter.

    Science.gov (United States)

    BOONE, C W; FIELD, J B

    1953-12-01

    The use of a tuberculin syringe as a burette has made possible an easy bedside technique for the determination of serum bicarbonate. By combining it with the use of a simple colorimeter, a relatively untrained person can do numerous bicarbonate determinations with a high degree of accuracy. The same technique also lends itself to other colorimetric clinical procedures such as determination of gastric acidity.

  20. DETERMINING SERUM BICARBONATE—A Simple Syringe Titrator and Colorimeter

    Science.gov (United States)

    Boone, Charles W.; Field, John B.

    1953-01-01

    The use of a tuberculin syringe as a burette has made possible an easy bedside technique for the determination of serum bicarbonate. By combining it with the use of a simple colorimeter, a relatively untrained person can do numerous bicarbonate determinations with a high degree of accuracy. The same technique also lends itself to other colorimetric clinical procedures such as determination of gastric acidity. PMID:13106724

  1. Seringas hipodérmicas descartáveis versus reutilizáveis: estudo de possíveis efeitos sobre o vírus da vacina viva, atenuada contra o sarampo Disposable versus reusable hypodermic syringes: study of feasible effects upon the virus of the live, attenuated measles vaccine

    Directory of Open Access Journals (Sweden)

    Edda de Rizzo

    1986-12-01

    Full Text Available Objetivou-se verificar entre seringas hipodérmicas descartáveis e reutilizáveis qual interfere mais com o vírus vivo presente na vacina contra o sarampo. Vacinas pertencentes a dois lotes foram reconstituídas com os dois tipos de seringas, de modo a formarem dois pools distintos, mantidos à temperatura de +2 a+8°C e protegidos da luz. De cada lote foram realizadas, no mínimo, seis titulações em paralelo, com amostragem a cada hora, de zero a seis horas após reconstituição. A análise estatística dos resultados obtidos nas titulações, feita pelo sistema de retas de regressão demonstrou que embora as vacinas manipuladas com ambos os tipos de seringas apresentassem um decréscimo de título estatisticamente significativo com o decorrer das horas, ele foi bem mais acentuado para as vacinas reconstituídas com seringas reutilizáveis. A menor interferência das descartáveis no título da vacina viva, atenuada contra o sarampo, demonstrou que a preconização e uso desse tipo de seringas pela Secretaria de Estado da Saúde de São Paulo é o ideal e recomendável, por preservar mais a vacina desde a reconstituição até sua administração e, conseqüentemente, a sua eficácia na prevenção dessa infecção.The study was performed in the State of S.Paulo, SP, Brazil, with the purpose of finding out whether reusable (glass and disposable hypodermic syringes used for administration of live attenuated measles vaccines would interfere with their virus. At least six different experiments using two distinct lots of vaccines were carried out. Each time, a lot was reconstituted with reusable and disposable syringes in parallel to form separate pools from which samples were collected hourly from zero to the sixtieth hour after reconstitution for virus titration in monolayers of Vero cells. The straight line regression system chosen for the analysis of the results demonstrated that although vaccines reconstituted with both types of syringes

  2. Professional ideologies and the development of syringe exchange: Wales as a case study.

    Science.gov (United States)

    Keene, J M; Stimson, G V

    1997-12-01

    This paper is derived from an evaluative study of HIV prevention programs for drug injectors across Wales. It considers how different professional territories and ideologies, concepts of drug misuse and models of HIV prevention may influence policy development. The research involved monitoring the introduction and development of agency and community based syringe exchange schemes and initiatives taken by community pharmacists. Interviews with staff, managers and administrators, and descriptions of service history, development and delivery inform the discussion. HIV prevention varied in different areas of Wales depending on the particular professional group involved, local ideologies regarding drug use treatment, and the extent to which HIV prevention was seen either as a specialist area of expertise and specific remit of drug workers or a generic health care task. Drug agencies with an abstinence policy rejected syringe exchange; instead, prevention in those areas developed in ad hoc ways as health care workers and pharmacists attempted to develop a community based service. Drug agencies with a pre-existing harm minimisation model easily integrated syringe exchange into their work and played the major part in establishing the service, but there was difficulty in extending it beyond their professional caseloads. As there were disincentives to use treatment agencies, and their catchment areas were limited, these factors influenced effective service provision.

  3. Confocal microscopic observation of structural changes in glass-ionomer cements and tooth interfaces.

    Science.gov (United States)

    Watson, T F; Pagliari, D; Sidhu, S K; Naasan, M A

    1998-03-01

    This study aimed to develop techniques to allow dynamic imaging of a cavity before, during and after placement of glass-ionomer restorative materials. Cavities were cut in recently extracted third molars and the teeth longitudinally sectioned. Each hemisected tooth surface was placed in green modelling compound at 90 to the optical axis of the microscope. The cavity surface was imaged using a video rate confocal microscope in conjunction with an internally focusable microscope objective. The sample on the stage was pushed up to the objective lens which 'clamped' the cover glass onto it. Water, glycerine or oil was placed below the coverglass, with oil above. Internal tooth structures were imaged by changing the internal focus of the objective. The restorative material was then placed into the cavity. Video images were stored either onto video tape or digitally, using a frame grabber, computer and mass memory storage. Software controls produced time-lapse recordings of the interface over time. Preliminary experiments have examined the placement and early maturation of conventional glass-ionomer cements and a syringeable resin-modified glass-ionomer cement. Initial contact of the cement matrix and glass particles was visible as the plastic material rolled past the enamel and dentine, before making a bond. Evidence for water movement from the dentine into the cement has also been seen. After curing, the early dimensional changes in the cements due to water flux were apparent using the time-lapse facility. This new technique enables examination of developing tooth/restoration interfaces and the tracking of movement in materials.

  4. The Prison Economy of Needles and Syringes: What Opportunities Exist for Blood Borne Virus Risk Reduction When Prices Are so High?

    Directory of Open Access Journals (Sweden)

    Carla Treloar

    Full Text Available A formal Needle and Syringe Program (NSP is not provided in Australian prisons. Injecting equipment circulates in prisons as part of an informal and illegal economy. This paper examined how this economy generates blood-borne virus (BBV risk and risk mitigation opportunities for inmates.The HITS-p cohort recruited New South Wales inmates who had reported ever injecting drugs and who had a negative HCV serological test within 12 months prior to enrolment. For this study, qualitative interviews were conducted with 30 participants enrolled in HITS-p. Participants included 10 women and were incarcerated in 12 prisons.A needle/syringe was nominated as being typically priced in the 'inside' prison economy at $100-$150, with a range of $50-$350. Purchase or hire of equipment was paid for in cash (including transactions that occurred outside prison and in exchange for drugs and other commodities. A range of other resources was required to enable successful needle/syringe economies, especially relationships with visitors and other prisoners, and violence to ensure payment of debts. Strategies to mitigate BBV risk included retaining one needle/syringe for personal use while hiring out others, keeping drug use (and ownership of equipment "quiet", stealing used equipment from the prison health clinic, and manufacture of syringes from other items available in the prison.The provision of prison NSP would disrupt the inside economies built around contraband needles/syringes, as well as minimise BBV risk. However, any model of prison NSP should be interrogated for any unanticipated markets that could be generated as a result of its regulatory practices.

  5. The Prison Economy of Needles and Syringes: What Opportunities Exist for Blood Borne Virus Risk Reduction When Prices Are so High?

    Science.gov (United States)

    Treloar, Carla; McCredie, Luke; Lloyd, Andrew R

    2016-01-01

    A formal Needle and Syringe Program (NSP) is not provided in Australian prisons. Injecting equipment circulates in prisons as part of an informal and illegal economy. This paper examined how this economy generates blood-borne virus (BBV) risk and risk mitigation opportunities for inmates. The HITS-p cohort recruited New South Wales inmates who had reported ever injecting drugs and who had a negative HCV serological test within 12 months prior to enrolment. For this study, qualitative interviews were conducted with 30 participants enrolled in HITS-p. Participants included 10 women and were incarcerated in 12 prisons. A needle/syringe was nominated as being typically priced in the 'inside' prison economy at $100-$150, with a range of $50-$350. Purchase or hire of equipment was paid for in cash (including transactions that occurred outside prison) and in exchange for drugs and other commodities. A range of other resources was required to enable successful needle/syringe economies, especially relationships with visitors and other prisoners, and violence to ensure payment of debts. Strategies to mitigate BBV risk included retaining one needle/syringe for personal use while hiring out others, keeping drug use (and ownership of equipment) "quiet", stealing used equipment from the prison health clinic, and manufacture of syringes from other items available in the prison. The provision of prison NSP would disrupt the inside economies built around contraband needles/syringes, as well as minimise BBV risk. However, any model of prison NSP should be interrogated for any unanticipated markets that could be generated as a result of its regulatory practices.

  6. Characterization of filters and filtration process using X-ray computerized tomography

    International Nuclear Information System (INIS)

    Maschio, Celio; Arruda, Antonio Celso Fonseca de

    1999-01-01

    The objective of this work is to present the potential of X-Ray computerized tomography as a tool for internal characterization of filters used in the solid-liquid separation, mainly the water filters. Cartridge filters (for industrial and domestic applications) contaminated with glass beads were used. The scanning process was carried out both with and without contaminant in the filter to compare the attenuation coefficient of the clean filter and the contaminated filter. The images showed that is possible the mapping the internal structure of the filters and the distribution of the contaminant, permitting a local analysis, that is not possible through the standard tests used by the manufactures. These standard tests reveal only global characteristics of the filter media. The possibility of application for manufacturing process control was also shown, because the non invasive nature is a important advantage of the technique, which also permitted damage detection in filters submitted to severe operational conditions. (author)

  7. [Safe injection rooms and police crackdowns in areas with heavy drug dealing. Evaluation by counting discarded syringes collected from the public space].

    Science.gov (United States)

    Vecino, Carmen; Villalbí, Joan R; Guitart, Anna; Espelt, Albert; Bartroli, Montserrat; Castellano, Yolanda; Brugal, M Teresa

    2013-01-01

    The evolution of drug injection in public places is analysed using as indicator the number of syringes collected from public spaces, evaluating as well the influence of public health harm reduction interventions and of police actions, with a before and after quasi experimental study. Monthly syringe counts on the semester before and after each intervention were compared both in the involved district and in the city as a whole, using the U and z tests with a 95% confidence level. The average number of collected syringes drops from 13.132 in 2004 to 3.190 in 2012. Comparing indicators before and after health and police interventions, the opening of a facility with a supervised drug consumption room in the inner city was associated with a huge reduction in the number of abandoned syringes in the city, while its number did not rise in the district where the facility was located. The subsequent opening of another drug consumption room did not have a significant impact in collected syringes in the area. Some police interventions in 2005-2006 and 2011 had a significant impact in the indicators of the involved districts, while others did not. Harm reduction programs might have a favourable impact on drug injection in public spaces and related syringe presence. Some police interventions appear to have an impact while others do not or just have a modest local and temporary effect.

  8. Multi-parameter studies of environmental aerosols with cascade track filters

    International Nuclear Information System (INIS)

    Ensinger, W.; Guo, S.-L.; Vater, P.; Brandt, R.

    2005-01-01

    Aerosols in the air in a factory processing nuclear reactor fuel material were collected by using cascade Kapton track filters with outer pore sizes of 12.8, 4.0 and 1.0μm consecutively and a conventional filter of glass fiber being behind to collect all aerosol particles left-over. The volume of air passed through the filters was measured by a flow meter. The weight of aerosol particles on each filter was obtained by the weight difference of the filter before and after collection of aerosol particles. α-activity on each filter was measured with a methane gas flow proportional counter. The sizes and elemental compositions of aerosol particles on the filters were analyzed by using a scanning electron microscope and an electron microprobe. Special attention was given to uranium aerosol particles. The median sizes of uranium aerosol particles were obtained being 1.97, 1.33 and 0.72μm on the first, second and third filter, respectively. The median size of all the uranium aerosol particles on the three track filters was 1.25μm

  9. Evaluation of the effect of media velocity on HEPA filter performance

    International Nuclear Information System (INIS)

    Alderman, Steven; Parsons, Michael; Hogancamp, Kristina; Norton, O. Perry; Waggoner, Charles

    2007-01-01

    Section FC of the ASME AG-1 Code addresses glass fiber HEPA filters and restricts the media velocity to a maximum of 2.54 cm/s (5 ft/min). Advances in filter media technology allow glass fiber HEPA filters to function at significantly higher velocities and still achieve HEPA performance. However, diffusional capture of particles < 100 nm is reduced at higher media velocities due to shorter residence times within the media matrix. Therefore, it is unlikely that higher media velocities for HEPA filters will be allowed without data to demonstrate the effect of media velocity on removal of particles in the smaller size classes. In order to address this issue, static testing has been conducted to generate performance related data and a range of dynamic testing has provided data regarding filter lifetimes, loading characteristics, changes in filter efficiency and the most penetrating particle size over time. Testing was conducted using 31 cm x 31 cm x 29 cm deep pleat HEPA filters supplied from two manufacturers. Testing was conducted at media velocities ranging from 2.0-4.5 cm/s with a solid aerosol challenge composed of potassium chloride. Two set of media velocity data were obtained for each filter type. In one set of evaluations, the maximum aerosol challenge particle size was limited to 3 μm, while particles above 3 μm were not constrained in the second set. This provided for considerable variability in the challenge mass mean diameter and overall mass loading rate. Results of this testing will be provided to the ASME AG-1 FC Committee for consideration in future versions of the HEPA standard. In general, the initial filter efficiency decreased with increasing media velocity. However, initial filter efficiencies were generally good in all cases. Filter efficiency values averaged over the first ten minute of the loading cycle ranged from 99.970 to 99.996 %. Additionally, the most penetrating particle size was observed to decrease with increasing media velocity

  10. Single patient doses of {sup 99m}Tc-HDP: Assessment of radiochemical purity, sterility and extractables from a polypropylene syringe over six hours

    Energy Technology Data Exchange (ETDEWEB)

    Parkes, S.L.; Varelis, P. [St George Hospital, Kogarah, NSW (Australia). Department of Nuclear Medicine

    1997-12-01

    Full text: The purpose of this investigation was to determine the radiochemical purity (RCP), sterility and extractables for {sup 99m}Tc oxidronate ({sup 99m}Tc-HDP) stored in polypropylene syringes over < six-hour period. The radiochemical purity was determined using a two-strip ITLC procedure, performed at time 0, 1, 2, 4, 6 hours. The sterility and endotoxin levels were tested by a NATA accredited laboratory, after allowing the radiopharmaceutical to stand at room temperature for six hours in the syringes. Plasticisers and other likely compounds that could be extracted from the syringes into the aqueous solution were determined by high pressure liquid chromatography (HPLC) diode array detection. This analysis involved shaking normal saline in a syringe over night and then injecting an aliquot of this solution onto a C18 analytical column and monitoring the effluent at 200 and 253 nm. The radiochemical purity of {sup 99m}Tc-HDP did not significantly change over the course of the study and remained above the recommended RCP for this radiopharmaceutical. Furthermore, at six hours the RCP of {sup 99m}Tc-HDP stored in both the manufacturer`s vial and a syringe were identical. Sterility testing of {sup 99m}Tc-HDP stored in syringes showed no microbial growth and less than 10 endotoxin units/mL (pass). The HPLC analysis did not show the presence of any extraneous compounds in the aqueous solution. Single patient doses of {sup 99m}Tc-HDP stored in polypropylene syringes over a six-hour period fulfill all the quality control requirements for administration to humans.

  11. [2000-year history of the ear syringe and its relationship to the enema. Images from the history of otorhinolaryngology, represented by instruments from the collection of the Ingolstadt Medical History Museum].

    Science.gov (United States)

    Feldmann, H

    1999-08-01

    SYRINGES WITH A PISTON AND THEIR USE AS "CLYSTER ORICULARIUS" IN THE ANCIENT ROME: Syringes with a piston were already known in ancient times and have been mentioned as a device for spraying rose water (Philon of Byzantium, about 230 BC), and for fighting fires (Heron of Alexandria about 110 AD). Celsus mentions it several times in his grand opus "De Medicina" (1st century AD) in the treatment of purulent discharge from the ear and for removing foreign bodies from the external ear canal. He always calls it "clyster oricularius", i.e. ear syringe, even when he describes its use in applications other than otological, such as in urology. Later the ear syringe fell from favor for a very long time and was reinvented only at the beginning of the 19th century. IRRIGATION OF THE BOWELS, FROM THE BAG SYRINGE TO THE PISTON SYRINGE: Irrigations of the bowels, clysters, were performed from ancient times to the 18th century with a baglike syringe using the bladder of animals as a pouch. Syringes with a piston were used by barbers and surgeons only for cleansing wounds or irrigating natural cavities of the body. Irrigation of the external ear canal had completely fallen from favor. In France in the 18th century large syringes with a piston made of tin oder brass came into use for enemas and replaced the old baglike devices. THE REINVENTION OF THE EAR SYRINGE AFTER THE PROTOTYPE OF THE ENEMA SYRINGE: Itard, an otologist in France in 1821, was the first to describe irrigating the ear with a syringe to remove hard wax. He recommended using an enema syringe ("seringue à lavement") for the procedure. Soon after his publication special ear syringes of appropriate size were developed and described by Beck in Freiburg, Germany, in 1827; by Fabrizi in Modena, Italy, 1839; and Schmalz in Dresden, Germany, 1846, who also introduced the kidney-shaped bowel for catching the water. Apart from that, small baglike syringes made of rubber were devised especially for use by the patient himself

  12. Are major reductions in new HIV infections possible with people who inject drugs? The case for low dead-space syringes in highly affected countries.

    Science.gov (United States)

    Zule, William A; Cross, Harry E; Stover, John; Pretorius, Carel

    2013-01-01

    Circumstantial evidence from laboratory studies, mathematical models, ecological studies and bio behavioural surveys, suggests that injection-related HIV epidemics may be averted or reversed if people who inject drugs (PWID) switch from using high dead-space to using low dead-space syringes. In laboratory experiments that simulated the injection process and rinsing with water, low dead space syringes retained 1000 times less blood than high dead space syringes. In mathematical models, switching PWID from high dead space to low dead space syringes prevents or reverses injection-related HIV epidemics. No one knows if such an intervention is feasible or what effect it would have on HIV transmission among PWID. Feasibility studies and randomized controlled trials (RCTs) will be needed to answer these questions definitively, but these studies will be very expensive and take years to complete. Rather than waiting for them to be completed, we argue for an approach similar to that used with needle and syringe programs (NSP), which were promoted and implemented before being tested more rigorously. Before implementation, rapid assessments that involve PWID will need to be conducted to ensure buy-in from PWID and other local stakeholders. This commentary summarizes the existing evidence regarding the protective effects of low dead space syringes and estimates potential impacts on HIV transmission; it describes potential barriers to transitioning PWID from high dead space to low dead space needles and syringes; and it presents strategies for overcoming these barriers. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Pollution by air filters: Continuous vs intermittent air flow

    NARCIS (Netherlands)

    Cox, C.W.J.; Bluyssen, P.M.

    2000-01-01

    Within the framework of the EU research project Airless, a long-term experiment of 28 weeks was carried out to investigate the influence of intermittent airflow compared to continuous airflow on the pollution effect of glass fibre filters (F7). No statistical relevant differences between odour

  14. Extractable substances (anionic surfactants) from membrane filters induce morphological changes in the green alga Scenedesmus obliquus (Chlorophyceae)

    NARCIS (Netherlands)

    Lürling, M.; Beekman, W.

    2002-01-01

    The effect of filtration of medium through different kinds of filters (glass fiber, mixed esters of cellulose and nitrocellulose) on the morphology in the green alga Scenedesmus obliquus was examined. Several compounds potentially released from membrane filters were further investigated, and among

  15. The Association Between Law Enforcement Encounters and Syringe Sharing Among IDUs on Skid Row: A Mixed Methods Analysis

    Science.gov (United States)

    Simon-Freeman, Rebecca; Bluthenthal, Ricky N.

    2013-01-01

    The legal environment is one factor that influences injection drug users' (IDUs) risk for HIV and other bloodborne pathogens such as hepatitis C virus (HCV). We examined the association between law enforcement encounters (i.e., arrests and citations) and receptive syringe sharing among IDUs in the context of an intensified policing effort. We conducted a mixed methods analysis of 30 qualitative and 187 quantitative interviews with IDUs accessing services at a Los Angeles, CA syringe exchange program from 2008 to 2009. Qualitative findings illustrate concerns related to visibility, drug withdrawal, and previous history of arrest/incarceration. In quantitative analysis, the number of citations received, current homelessness, and perceiving that being arrested would be a “big problem” were independently associated with recent syringe sharing. Findings illustrate some of the unintended public health consequences associated with intensified street-level policing, including risk for HIV and HCV transmission. PMID:23620243

  16. Federal funding for syringe exchange in the US: Explaining a long-term policy failure.

    Science.gov (United States)

    Showalter, David

    2018-05-01

    The United States prohibited federal funding for syringe exchange programs for people who inject drugs nearly continuously from 1988 to 2015, despite growing scientific evidence, diminishing AIDS-related controversy, and tens of thousands of deaths from injection-related AIDS. This study investigates the political and institutional bases of this long-term failure to support lifesaving public policy. This study draws on national, regional, and local media coverage, archival sources, and semi-structured, in-depth interviews with 6 long-time syringe exchange researchers and activists from California. I use case-oriented process tracing methods to explain the persistence and reform of the federal funding ban. Though previous studies focus on the symbolic clash between conservative morality and empirical science, I find that changing demographic and regional inequalities in the effects of the AIDS epidemic and dynamics produced by the federal structure of US government were more important factors in the creation and persistence of the funding ban. The persistence and eventual repeal of the ban on federal funding for syringe exchange was a product of the changing demographic, geographic, and political effects of the AIDS epidemic within the federal structure of US government, rather than a consequence of intractable morality politics. These contextual dynamics continue to shape AIDS and public health policy at all levels of government. Copyright © 2018. Published by Elsevier B.V.

  17. The efficiency of Whatman Type ACG/B filter papers for methyl iodine retention in air

    International Nuclear Information System (INIS)

    Davis, R.E.; Williams, J.M.E.

    1965-11-01

    Experiments are described in which charcoal impregnated glass fibre filter papers Type ACG/B were exposed to methyl iodide vapour and the penetration determined for iodide loadings ranging from 2 x 10 - 7 to 2x10 - 1 μg/cm 2 of filter area. Air was subsequently passed through the filters, and at intervals the amount of methyl iodide remaining on them was determined. Penetrations during loading varied from 30% to 80%, but after 10 minutes elution all filters retained less than 5% of the methyl iodide originally present. (author)

  18. Selection of filter media in alpha air monitors for emergency environmental monitoring

    International Nuclear Information System (INIS)

    Kinouchi, N.; Oishi, T.; Noguchi, H.; Kato, S.

    2000-01-01

    We have developed an alpha air monitor which is possible to measure rapidly and sensitively the concentrations of airborne alpha-emitting particles, such as plutonium, for the environmental monitoring at an accident of nuclear reprocessing plant. The monitor is designed to collect airborne alpha-emitting particles by drawing the ambient air through a filter and to detect the activity by alpha spectroscopy. In order to achieve high-sensitive measurements, selection of a suitable filter used in the monitor is considerably important. The most important requirement for the filter is that it has a high surface collection efficiency to obtain the sharpness of the alpha energy spectrum. This makes it easy to distinguish the alpha-ray peak of plutonium from the alpha spectrum of naturally occurring radon decay products in the environment. And the filter is also desired to have low resistance of the air flow so that particles can be collected at a high flowrate. We have made a comparison of the surface collection efficiency and pressure drop for the various filters. Types of the test filters, most of which are commercially available in Japan, were glass fiber, cellulose-glass fiber, membrane and so on. The surface collection efficiency has been evaluated by the following two indices. One was the sharpness of alpha-ray energy peaks of thoron decay products generated in a laboratory and collected in the fibers. The other was the background counts of radon decay products in a plutonium region by measuring alpha-ray energy spectrum of radon decay products collected in the filters by sampling of dust in the atmosphere. It was found that the PTFE (polytetrafluoroethylene) membrane filter with backing had a high surface collection efficiency and low pressure drop. The results of the test are described in detail in this paper. (author)

  19. A clinical comparative study between conventional and camouflaged syringes to evaluate behavior and anxiety in 6-11-year-old children during local anesthesia administration-a novel approach.

    Science.gov (United States)

    Melwani, Anjana M; Srinivasan, Ila; Setty, Jyothsna V; D R, Murali Krishna; Pamnani, Sunaina S; Lalitya, Dandamudi

    2018-02-01

    The sight of dental injection can bring about severe anxiety in children. Therefore, an alternative method that is convenient, effective, and keeps the needle hidden making it child friendly is necessary. The objective of the study was to compare the efficacy of a camouflaged syringe and conventional syringe on behavior and anxiety in 6-11-year-old children during local anesthesia administration. The study was a randomized, crossover clinical study including 30 children. Children were separated into two groups. Group 1 consisted of 15 children aged 6-8 years while group 2 consisted of 15 children aged 9-11 years. This study involved two sessions wherein all the children were injected using conventional and camouflaged syringes in separate sessions. Their behavior was assessed using the Faces, Legs, Activity, Cry, Consolability (FLACC) behavior pain scale and anxiety was assessed by measuring changes in pulse rate. Patient and operator preferences were compared. The results showed a lower mean change in pulse rate and FLACC scores in the camouflaged group, suggesting a positive behavior and lesser anxiety with camouflaged syringes than with conventional syringes. The use of camouflaged syringes for anesthesia was demonstrated to be effective in improving the behavior of children and decreasing their anxiety, and is therefore recommended as an alternative to the use of conventional syringes for local anesthesia.

  20. The effect of silver on the optical, spectral-luminescent, and crystallization properties of bromide photo-thermo-refractive glasses

    Science.gov (United States)

    Oreshkina, K. V.; Dubrovin, V. D.; Ignat'ev, A. I.; Nikonorov, N. V.

    2017-10-01

    The effect of silver on the optical, spectral-luminescent, and crystallization properties of bromide photo-thermo-refractive glasses is studied. Multicomponent photosensitive glasses of the Na2O-ZnO-Al2O3-SiO2 system with photosensitizing agents (cerium, antimony, silver) and halogenides (fluorine and bromine) are synthesized. Ultraviolet irradiation and thermal treatment below the glass-transition temperature of the glasses cause the formation of silver molecular clusters, which exhibit luminescence in the visible and infrared regions. UV irradiation and thermal treatment of glasses above the glass-transition temperature lead to the growth of silver nanoparticles with plasmon resonance peak in the region of 420 nm. Further thermal treatment of glasses above the glass-transition temperature shifts the plasmon-resonance maximum by 70 nm to longer wavelengths, which is related to the growth of a crystalline shell consisting of mixed silver and sodium bromides on nanoparticles. This formation of a crystalline phase on colloidal centers results in a local increase in the refractive index of the irradiated region by +Δ n 900 ppm compared to the nonirradiated region. Photo-thermo-refractive glasses with increased silver concentration are promising photosensitive materials for creating holographic optical elements and devices for line narrowing and stabilizing filters, spectral beam combiners, and filters for increasing the spectral brightness of laser diodes. A positive change in the refractive index of Photo-thermo-refractive glasses provides the possibility of recording in them 3D waveguide and integrated-optical structures.

  1. Multiple access to sterile syringes for injection drug users: vending machines, needle exchange programs and legal pharmacy sales in Marseille, France.

    Science.gov (United States)

    Moatti, J P; Vlahov, D; Feroni, I; Perrin, V; Obadia, Y

    2001-03-01

    In Marseille, southeastern France, HIV prevention programs for injection drug users (IDUs) simultaneously include access to sterile syringes through needle exchange programs (NEPs), legal pharmacy sales and, since 1996, vending machines that mechanically exchange new syringes for used ones. The purpose of this study was to compare the characteristics of IDUs according to the site where they last obtained new syringes. During 3 days in September 1997, all IDUs who obtained syringes from 32 pharmacies, four NEPs and three vending machines were offered the opportunity to complete a self-administered questionnaire on demographics, drug use characteristics and program utilization. Of 485 individuals approached, the number who completed the questionnaire was 141 in pharmacies, 114 in NEPs and 88 at vending machines (response rate = 70.7%). Compared to NEP users, vending machine users were younger and less likely to be enrolled in a methadone program or to report being HIV infected, but more likely to misuse buprenorphine. They also had lower financial resources and were less likely to be heroin injectors than both pharmacy and NEP users. Our results suggest that vending machines attract a very different group of IDUs than NEPs, and that both programs are useful adjuncts to legal pharmacy sales for covering the needs of IDUs for sterile syringes in a single city. Assessment of the effectiveness and cost-effectiveness of combining such programs for the prevention of HIV and other infectious diseases among IDUs requires further comparative research. Copyright 2001 S. Karger AG, Basel

  2. Product consistency leach tests of Savannah River Site radioactive waste glasses

    International Nuclear Information System (INIS)

    Bibler, N.E.; Bates, J.K.

    1989-01-01

    The Product Consistency Test (PCT) is a glass leach test that was developed at the Savannah River Site (SRS) to routinely confirm the durability of nuclear waste glasses that will be produced in the Defense Waste Processing Facility. The PCT is a 7 day, crushed glass leach test in deionized water at 90 degree C. Final leachates are filtered and acidified prior to analysis. To demonstrate the reproducibility of the PCT when performed remotely, SRS and Argonne National Laboratory have performed the PCT on samples of two radioactive glasses. The tests were also performed to compare the releases of the radionuclides with the major nonradioactive glass components and to determine if radiation from the glass was affecting the results of the PCT. The test was performed in triplicate at each laboratory. For the major soluble elements, B, Li, Na, and Si, in the glass, each investigator obtained relative precisions in the range 2--5% in the triplicate tests. This range indicates good precision for the PCT when performed remotely with master slave manipulators in a shielded cell environment

  3. Correlates of lending needles/syringes among HIV-seropositive injection drug users.

    Science.gov (United States)

    Metsch, Lisa R; Pereyra, Margaret; Purcell, David W; Latkin, Carl A; Malow, Robert; Gómez, Cynthia A; Latka, Mary H

    2007-11-01

    Among HIV-positive injection drug users (IDUs), we examined the correlates of lending needles/syringes with HIV-negative and unknown status injection partners. HIV-positive IDUs (N=738) from 4 cities in the United States who reported injection drug use with other IDUs in the past 3 months participated in an audio computer-assisted self-administered interview. Eighteen percent of study participants self-reported having lent their needles to HIV-negative or unknown status injection partners. Multivariate analyses showed that 6 variables were significantly associated with this high-risk injecting practice. Older IDUs, high school graduates, and those reporting more supportive peer norms for safer drug use were less likely to lend needles/syringes. Admission to a hospital for drug treatment in the past 6 months, having injected with >1 person in the past 3 months, and having more psychiatric symptoms were all associated with more risk. These findings underscore the need for a continued prevention focus on HIV-positive IDUs that recognizes the combination of drug use, mental health factors, and social factors that might affect this high-risk injecting practice, which could be associated with HIV and hepatitis C transmission.

  4. Eliminating drift of the head gesture reference to enhance Google Glass-based control of an NAO humanoid robot

    Directory of Open Access Journals (Sweden)

    Xiaoqian Mao

    2017-03-01

    Full Text Available This article presents a strategy for hand-free control of an NAO humanoid robot via head gesture detected by Google Glass-based multi-sensor fusion. First, we introduce a Google Glass-based robot system by integrating the Google Glass and the NAO humanoid robot, which is able to send robot commands through Wi-Fi communications between the Google Glass and the robot. Second, we detect the operator’s head gestures by processing data from multiple sensors including accelerometers, geomagnetic sensors and gyroscopes. Next, we use a complementary filter to eliminate drift of the head gesture reference, which greatly improves the control performance. This is accomplished by the high-pass filter component on the control signal. Finally, we conduct obstacle avoidance experiments while navigating the robot to validate the effectiveness and reliability of this system. The experimental results show that the robot is smoothly navigated from its initial position to its destination with obstacle avoidance via the Google Glass. This hands-free control system can benefit those with paralysed limbs.

  5. Experimental investigation of in situ cleanable HEPA filter

    International Nuclear Information System (INIS)

    Adamson, D.J.

    1999-01-01

    The Westinghouse Savannah River Company located at the Savannah River Site (SRS) in Aiken, South Carolina is currently testing the feasibility of developing an in situ cleanable high efficiency particulate air (HEPA) filter system. Sintered metal filters are being tested for regenerability or cleanability in simulated conditions found in a high level waste (HLW) tank ventilation system. The filters are being challenged using materials found in HLW tanks. HLW simulated salt, HLW simulated sludge and South Carolina road dust. Various cleaning solutions have been used to clean the filters in situ. The tanks are equipped with a ventilation system to maintain the tank contents at negative pressure to prevent the release of radioactive material to the environment. This system is equipped with conventional disposable glass-fiber HEPA filter cartridges. Removal and disposal of these filters is not only costly, but subjects site personnel to radiation exposure and possible contamination. A test apparatus was designed to simulate the ventilation system of a HLW tank with an in situ cleaning system. Test results indicate that the Mott sintered metal HEPA filter is suitable as an in situ cleanable or regenerable HEPA filter. Data indicates that high humidity or water did not effect the filter performance and the sintered metal HEPA filter was easily cleaned numerous times back to new filter performance by an in situ spray system. The test apparatus allows the cleaning of the soiled HEPA filters to be accomplished without removing the filters from process. This innovative system would eliminate personnel radiation exposure associated with removal of contaminated filters and the high costs of filter replacement and disposal. The results of these investigations indicate that an in situ cleanable HEPA filter system for radioactive and commercial use could be developed and manufactured

  6. Gravimetric and dilatometric research of elements action on three dimensional filter by themal effects

    Directory of Open Access Journals (Sweden)

    B. K. Shayakhmetov

    2014-01-01

    Full Text Available In the work there are presented the results of studying the filtering elements weight changes when heated. For all the variants of filtering elements at the primary stages of heating there is characteristic increasing their linear dimensions due to their thermal expansion. It was established that using hydrolyzed ethyl silicate as a binder, as well as water solution of liquid glass with addition of aluminum powder in the refractory material permits to obtain filtering elements without high-temperature solid-phase sintering.

  7. Filtration through nylon membranes negatively affects analysis of arsenic and phosphate by the molybdenum blue method

    DEFF Research Database (Denmark)

    Heimann, Axel Colin; Jakobsen, Rasmus

    2007-01-01

    Filtering synthetic arsenic- or phosphate-containing solutions (1.5-47.6 mu mol/L) with nylon syringe filters significantly reduced absorbances (by 6-74%) when analyzed with the colorimetric molybdenum blue method. Filtering the same solutions with cellulose acetate syringe filters yielded...... no significant differences as compared to unfiltered controls. The detrimental effect of nylon membranes was also observed when pure Milli-Q water was filtered and Subsequently spiked with arsenic(III) or phosphate suggesting that some compound(s) eluting from the filter membranes interfere with the color...... formation in the assay. Consequently, we caution against using nylon filters when filtering water samples for the determination of arsenic or phosphate with the molybdenum blue method....

  8. Stability of busulfan solutions in polypropylene syringes and infusion bags as determined with an original assay.

    Science.gov (United States)

    Guichard, Nicolas; Bonnabry, Pascal; Rudaz, Serge; Fleury-Souverain, Sandrine

    2017-11-15

    The stability of busulfan solution in 0.9% sodium chloride and stored in polypropylene syringes or infusion bags was evaluated. Busulfan solutions (0.54 mg/mL) were prepared and transferred to 50-mL polypropylene syringes and 100- and 500-mL polypropylene infusion bags and stored at 2-8 and 23-27 °C. Chemical stability was measured using a stability-indicating, ultrahigh performance liquid chromatography coupled to mass spectrometry method. The stability of busulfan was assessed by measuring the percentage of the initial concentration remaining at the end of each time point of analysis. The initial busulfan concentration was defined as 100%. Stability was defined as retention of at least 90% of the initial busulfan concentration. A visual inspection of the samples for particulate matter, clarity, and color without instrumentation of magnification was conducted at each time point of analysis. The visual inspection demonstrated no influence of the storage container when busulfan infusions diluted in 0.9% sodium chloride injection were stored at 23-27 °C. No color change or precipitate was observed at this temperature; however, a rapid decrease of the busulfan content in all containers stored at room temperature was observed. Busulfan in syringes was chemically stable for 12 hours, while busulfan in infusion bags (100 and 500 mL) was stable only for 3 hours at 23-27 °C. Busulfan 0.54-mg/mL solution in 0.9% sodium chloride injection was physically and chemically stable for 30 hours when stored in 50-mL polypropylene syringes at 2-8 °C and protected from light. Copyright © 2017 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  9. GA103: A microprogrammable processor for online filtering

    International Nuclear Information System (INIS)

    Calzas, A.; Danon, G.; Bouquet, B.

    1981-01-01

    GA 103 is a 16 bit microprogrammable processor which emulates the PDP 11 instruction set. It is based on the Am 2900 slices. It allows user-implemented microinstructions and addition of hardwired processors. It will perform on-line filtering tasks in the NA 14 experiment at CERN, based on the reconstruction of transverse momentum of photons detected in a lead glass calorimeter. (orig.)

  10. Manufacturing and testing of wavefront filters for DARWIN

    Science.gov (United States)

    Flatscher, R.; Artjushenko, V.; Sakharova, T.; Pereira do Carmo, Joao

    2017-11-01

    Wavefront filtering is mandatory in the realisation of nulling interferometers with high star light suppression capability required to detect extrasolar planets, such as the one foreseen for the ESA Darwin mission. This paper presents the design, manufacturing, and test results of single mode fibres to be used as wavefront filters in mid-infrared range. Fibres made from chalcogenide glass and silver halide crystals were produced. The first class can serve as wavefront filters up to a wavelength of 11 microns, while silver halide fibres can be used over the full Darwin wavelength range from 6.5 to 18 micron. The chalcogenide glass fibres were drawn by double crucible method whereas polycrystalline fibres from silver halides were fabricated by multiple extrusion from a crystalline preform. Multi-layer AR-coatings for fibre ends were developed and environmentally tested for both types of fibres. Special fibre facet polishing procedures were established, in particular for the soft silver halide fibre ends. Cable design and assembly process were also developed, including termination by SMA-connectors with ceramic ferrules and fibre protection by loose PEEK-tubings to prevent excessive bending and chemical attacks for fibres. The wavefront filtering capability of the fibres was demonstrated on a high quality Mach-Zehnder interferometer. Two different groups of laser sources were used to measure the wavefront filtering of the fibres by using a CO-laser for testing in the lower sub-band and a CO2-laser to check the upper sub-band. Measurements of the fibres far field intensity distribution and transmission were performed for numerous cable samples. Single mode behaviour was observed in more than 25 silver halide fibre cables before AR-coating of their ends, while after that 17 cables were compliant with all technical requirements. Residual cladding modes existing in short single mode fibres were effectively removed by applying of a proper absorbing jacket to the fibre

  11. HIV Risk Behavior among Amphetamine Injectors at U.S. Syringe Exchange Programs

    Science.gov (United States)

    Braine, Naomi; Des Jarlais, Don C.; Goldblatt, Cullen; Zadoretzky, Cathy; Turner, Charles

    2005-01-01

    The goal of this study was to compare HIV risk behaviors of amphetamine and non-amphetamine injectors at syringe exchange programs (SEP) in the United States and to identify factors associated with injection risk. This analysis is based on data from a random cross-section of participants at 13 SEPs in different parts of the country. All interviews…

  12. Behavioral response and pain perception to computer controlled local anesthetic delivery system and cartridge syringe

    Directory of Open Access Journals (Sweden)

    T D Yogesh Kumar

    2015-01-01

    Full Text Available Aim: The present study evaluated and compared the pain perception, behavioral response, physiological parameters, and the role of topical anesthetic administration during local anesthetic administration with cartridge syringe and computer controlled local anesthetic delivery system (CCLAD. Design: A randomized controlled crossover study was carried out with 120 children aged 7-11 years. They were randomly divided into Group A: Receiving injection with CCLAD during first visit; Group B: Receiving injection with cartridge syringe during first visit. They were further subdivided into three subgroups based on the topical application used: (a 20% benzocaine; (b pressure with cotton applicator; (c no topical application. Pulse rate and blood pressure were recorded before and during injection procedure. Objective evaluation of disruptive behavior and subjective evaluation of pain were done using face legs activity cry consolability scale and modified facial image scale, respectively. The washout period between the two visits was 1-week. Results: Injections with CCLAD produced significantly lesser pain response, disruptive behavior (P < 0.001, and pulse rate (P < 0.05 when compared to cartridge syringe injections. Application of benzocaine produced lesser pain response and disruptive behavior when compared to the other two subgroups, although the result was not significant. Conclusion: Usage of techniques which enhance behavioral response in children like injections with CCLAD can be considered as a possible step toward achieving a pain-free pediatric dental practice.

  13. Treatment of herniated lumbar disc by percutaneous laser disc decompression combined with synchronous suction technique through syringe

    Institute of Scientific and Technical Information of China (English)

    Dhir B. Gurung; Gaojian Tao; Hongyi Lin; Yanning Qian; Jian Lin

    2007-01-01

    Objective: To compare the outcomes of percutaneous laser disc decompression (PLDD) and PLDD with synchronous suction through syringe in the patients with herniated lumbar disc (HLD). Methods: Forty-two patients with HLD on MRI and those who did not respond to conservative treatment for 6 weeks were randomly divided into group A and group B. In group A, the patients were treated with PLDD and those in group B with PLDD and synchronous suction through syringe. GaAIAS diode laser at 810 nm was used for the ablation in both groups. The treatment effect was evaluated by modified MacNab's criteria on the 7th, 30th and 90th day. Results: Evaluated by modified MacNab's criteria, the percentages of the excellent and good cases in total patients treated for group B and A were 80.95% and 57.14% on the 7th follow-up day, 85.71% and 66.67% on the 30th follow-up day, and 95.24% and 71.43% on the 90th follow-up day, respectively. Conclusion: Synchronous suction technique through syringe during PLDD improves the overall outcome in the treatment of herniated lumbar disc.

  14. Trend Analyses of Users of a Syringe Exchange Program in Philadelphia, Pennsylvania: 1999-2014.

    Science.gov (United States)

    Maurer, Laurie A; Bass, Sarah Bauerle; Ye, Du; Benitez, José; Mazzella, Silvana; Krafty, Robert

    2016-12-01

    This study examines trends of injection drug users' (IDUs) use of a Philadelphia, Pennsylvania, syringe exchange program (SEP) from 1999 to 2014, including changes in demographics, drug use, substance abuse treatment, geographic indicators, and SEP use. Prevention Point Philadelphia's SEP registration data were analyzed using linear regression, Pearson's Chi square, and t-tests. Over time new SEP registrants have become younger, more racially diverse, and geographically more concentrated in specific areas of the city, corresponding to urban demographic shifts. The number of new registrants per year has decreased, however syringes exchanged have increased. Gentrification, cultural norms, and changes in risk perception are believed to have contributed to the changes in SEP registration. Demographic changes indicate outreach strategies for IDUs may need adjusting to address unique barriers for younger, more racially diverse users. Implications for SEPs are discussed, including policy and continued ability to address current public health threats.

  15. Study on the Metal Fiber Filter Modeling for Capturing Radioactive Aerosol

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seunguk; Lee, Chanhyun; Park, Minchan; Lee, Jaekeun [EcoEnergy Research Institute, Busan (Korea, Republic of)

    2015-05-15

    The components of air cleaning system are demisters to remove entrained moisture, pre-filters to remove the bulk of the particulate matter, high efficiency particulate air (HEPA) filters, iodine absorbers(generally, activated carbon) and HEPA filters after the absorbers for redundancy and collection of carbon fines. The HEPA filters are most important components to prevent radioactive aerosols from being released to control room and adjacent environment. The Conventional HEPA filter has pleated media for low pressure drop. Consequently, the filters must provide high collection efficiency as well as low pressure drop. Unfortunately, conventional HEPA filters are made of glass fiber and polyester, and pose disposal issues since they cannot be recycled. In fact, 31,055 HEPA filters used in nuclear facilities in the U.S are annually disposed. The Analyses at face velocities 1cm/s and 10cm/s are also carried out, and they also show R2 value of 0.995. However, since official HEPA filter standards are established at face velocity of 5cm/s, this value will be used in further analysis. From the comparative studies carried out at different filter thickness and face velocities, a good correlation is found between the model and the experiment.

  16. Contact with hospital syringes containing body fluids: implications for medical waste management regulation Jeringas en contacto con sangre y fluidos corporales utilizadas en el hospital: implicaciones para el manejo de desechos hospitalarios

    OpenAIRE

    Patricia Volkow; Bénédicte Jacquemin; Diana Vilar-Compte; José Ramón Castillo

    2003-01-01

    OBJECTIVE: To determine amount of syringes used in the hospital and extent of contact with blood and body fluids of these syringes. MATERIAL AND METHODS: Syringe use was surveyed at a tertiary care center for one week; syringes were classified into the following four categories according to use: a) contained blood; b) contained other body fluids (urine, gastric secretion, cerebrospinal fluid, wound drainage); c) used exclusively for drug dilution and application in plastic intravenous (IV) tu...

  17. The impact of harm reduction programs and police interventions on the number of syringes collected from public spaces. A time series analysis in Barcelona, 2004-2014.

    Science.gov (United States)

    Espelt, A; Villalbí, J R; Bosque-Prous, M; Parés-Badell, O; Mari-Dell'Olmo, M; Brugal, M T

    2017-12-01

    To estimate the effect of opening two services for people who use drugs and three police interventions on the number of discarded syringes collected from public spaces in Barcelona between 2004 and 2014. We conducted an interrupted time-series analysis of the monthly number of syringes collected from public spaces during this period. The dependent variable was the number of syringes collected per month. The main independent variables were month and five dummy variables (the opening of two facilities with safe consumption rooms, and three police interventions). To examine which interventions affected the number of syringes collected, we performed an interrupted time-series analysis using a quasi-Poisson regression model, obtaining relative risks (RR) and 95% confidence intervals (CIs). The number of syringes collected per month in Barcelona decreased from 13,800 in 2004 to 1655 in 2014 after several interventions. For example, following the closure of an open drug scene in District A of the city, we observed a decreasing trend in the number of syringes collected [RR=0.88 (95% CI: 0.82-0.95)], but an increasing trend in the remaining districts [RR=1.11 (95% CI: 1.05-1.17) and 1.08 (95% CI: 0.99-1.18) for districts B and C, respectively]. Following the opening of a harm reduction facility in District C, we observed an initial increase in the number collected in this district [RR=2.72 (95% CI: 1.57-4.71)] and stabilization of the trend thereafter [RR=0.97 (95% CI: 0.91-1.03)]. The overall number of discarded syringes collected from public spaces has decreased consistently in parallel with a combination of police interventions and the opening of harm reduction facilities. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Determination of bismuth and cadmium after solid-phase extraction with chromosorb-107 in a syringe

    International Nuclear Information System (INIS)

    Tokman, Nilgun; Akman, Suleyman

    2004-01-01

    The determination of bismuth and cadmium by graphite furnace atomic absorption spectrometry (GFAAS) after solid-phase extraction (SPE) on Chromosorb-107 filled in a syringe was described. To retain the analytes, the sample solution treated with and without ammonium pyrolidine dithiocarbamate (APDC) was drawn into the syringe filled with Chromosorb-107 and discharged back manually. Bismuth and cadmium were quantitatively sorbed at pH ≥ 6 irrespective of whether the analyte was complexed with APDC prior to passing through the Chromosorb-107. Analyte elements sorbed on the resin were quantitatively eluted with 3.0 M of HNO 3 again drawing and discharging the eluent into the syringe and ejected it back. Optimum flow rates of sample or eluent for sorption and elution processes were 20 ml min -1 for drawing and 20 ml min -1 for discharging in all cases. Bismuth and cadmium were analyzed by graphite furnace atomic absorption spectrometry. The elements could be concentrated by drawing and discharging several portions of sample successively but eluting only one time. The validity of the proposed method was checked with standard reference materials (NIST SRM 1515 Apple-Leaves, CWW-TM-E Waste Water and CRM-SW Sea Water). The analyte elements were quantitatively (>95%) recovered from different matrices irrespective of treated samples with APDC. Detection limits (δ) were 0.8 and 1.2 μg l -1 for Bi and Cd, respectively. The method can be characterized with fastness, simplicity, quantitative recovery and high reproducibility

  19. Syringe shape and positioning relative to efficiency volume inside dose calibrators and its role in nuclear medicine quality assurance programs

    International Nuclear Information System (INIS)

    Santos, J.A.M.; Carrasco, M.F.; Lencart, J.; Bastos, A.L.

    2009-01-01

    A careful analysis of geometry and source positioning influence in the activity measurement outcome of a nuclear medicine dose calibrator is presented for 99m Tc. The implementation of a quasi-point source apparent activity curve measurement is proposed for an accurate correction of the activity inside several syringes, and compared with a theoretical geometric efficiency model. Additionally, new geometrical parameters are proposed to test and verify the correct positioning of the syringes as part of acceptance testing and quality control procedures.

  20. Syringe shape and positioning relative to efficiency volume inside dose calibrators and its role in nuclear medicine quality assurance programs

    Energy Technology Data Exchange (ETDEWEB)

    Santos, J.A.M. [Servico de Fisica Medica, Instituto Portugues de Oncologia do Porto Francisco Gentil, E.P.E., Rua Dr. Antonio Bernardino de Almeida, 4200072 Porto (Portugal); Centro de Investigacao, Instituto Portugues de Oncologia do Porto Francisco Gentil, E.P.E., Rua Dr. Antonio Bernardino de Almeida, 4200072 Porto (Portugal)], E-mail: a.miranda@portugalmail.pt; Carrasco, M.F. [Servico de Fisica Medica, Instituto Portugues de Oncologia do Porto Francisco Gentil, E.P.E., Rua Dr. Antonio Bernardino de Almeida, 4200072 Porto (Portugal); Centro de Investigacao, Instituto Portugues de Oncologia do Porto Francisco Gentil, E.P.E., Rua Dr. Antonio Bernardino de Almeida, 4200072 Porto (Portugal); Lencart, J. [Servico de Fisica Medica, Instituto Portugues de Oncologia do Porto Francisco Gentil, E.P.E., Rua Dr. Antonio Bernardino de Almeida, 4200072 Porto (Portugal); Bastos, A.L. [Servico de Medicina Nuclear, Instituto Portugues de Oncologia do Porto Francisco Gentil, E.P.E., Rua Dr. Antonio Bernardino de Almeida, 4200072 Porto (Portugal)

    2009-06-15

    A careful analysis of geometry and source positioning influence in the activity measurement outcome of a nuclear medicine dose calibrator is presented for {sup 99m}Tc. The implementation of a quasi-point source apparent activity curve measurement is proposed for an accurate correction of the activity inside several syringes, and compared with a theoretical geometric efficiency model. Additionally, new geometrical parameters are proposed to test and verify the correct positioning of the syringes as part of acceptance testing and quality control procedures.

  1. Determination of mercury in airborne particulate matter collected on glass fiber filters using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sampling

    Energy Technology Data Exchange (ETDEWEB)

    Araujo, Rennan G.O., E-mail: rgoa01@terra.com.br [Laboratorio de Quimica Analitica Ambiental, Departamento de Quimica, Universidade Federal de Sergipe, Campus Sao Cristovao, 49.100-000, Sao Cristovao, SE (Brazil); Departamento de Quimica, Universidade Federal de Santa Catarina, 88040-900, Florianopolis, SC (Brazil); Vignola, Fabiola; Castilho, Ivan N.B. [Departamento de Quimica, Universidade Federal de Santa Catarina, 88040-900, Florianopolis, SC (Brazil); Borges, Daniel L.G.; Welz, Bernhard [Departamento de Quimica, Universidade Federal de Santa Catarina, 88040-900, Florianopolis, SC (Brazil); Instituto Nacional de Ciencia e Tecnologia do CNPq, INCT de Energia e Ambiente, Universidade Federal da Bahia, 40170-115 Salvador, BA (Brazil); Vale, Maria Goreti R. [Instituto Nacional de Ciencia e Tecnologia do CNPq, INCT de Energia e Ambiente, Universidade Federal da Bahia, 40170-115 Salvador, BA (Brazil); Instituto de Quimica, Universidade Federal do Rio Grande do Sul, 91501-970 Porto Alegre, RS (Brazil); Smichowski, Patricia [Comision Nacional de Energia Atomica (CNEA) and Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET), Buenos Aires (Argentina); Ferreira, Sergio L.C. [Instituto Nacional de Ciencia e Tecnologia do CNPq, INCT de Energia e Ambiente, Universidade Federal da Bahia, 40170-115 Salvador, BA (Brazil); Instituto de Quimica, Universidade Federal da Bahia, 40170-290, Salvador, BA (Brazil); Becker-Ross, Helmut [Leibniz-Institut fuer Analytische Wissenschaften-ISAS-e.V., Department Berlin, 12489 Berlin (Germany)

    2011-05-15

    A study has been undertaken to assess the capability of high-resolution continuum source graphite furnace atomic absorption spectrometry for the determination of mercury in airborne particulate matter (APM) collected on glass fiber filters using direct solid sampling. The main Hg absorption line at 253.652 nm was used for all determinations. The certified reference material NIST SRM 1648 (Urban Particulate Matter) was used to check the accuracy of the method, and good agreement was obtained between published and determined values. The characteristic mass was 22 pg Hg. The limit of detection (3{sigma}), based on ten atomizations of an unexposed filter, was 40 ng g{sup -1}, corresponding to 0.12 ng m{sup -3} in the air for a typical air volume of 1440 m{sup 3} collected within 24 h. The limit of quantification was 150 ng g{sup -1}, equivalent to 0.41 ng m{sup -3} in the air. The repeatability of measurements was better than 17% RSD (n = 5). Mercury concentrations found in filter samples loaded with APM collected in Buenos Aires, Argentina, were between < 40 ng g{sup -1} and 381 {+-} 24 ng g{sup -1}. These values correspond to a mercury concentration in the air between < 0.12 ng m{sup -3} and 1.47 {+-} 0.09 ng m{sup -3}. The proposed procedure was found to be simple, fast and reliable, and suitable as a screening procedure for the determination of mercury in APM samples.

  2. Sorption of per- and polyfluoroalkyl substances (PFASs) on filter media: implications for phase partitioning studies.

    Science.gov (United States)

    Chandramouli, Bharat; Benskin, Jonathan P; Hamilton, M Coreen; Cosgrove, John R

    2015-01-01

    Per- and polyfluoroalkyl substances (PFASs), including perfluorooctanoic acid (PFOA) and perfluorooctanesulfonic acid (PFOS), are ubiquitous in the environment. Investigations into their fate and potential phase-partitioning behavior require separating solid from aqueous phases via filtration. However, sorption of aqueous-phase PFASs on filtration media may lead to underestimation of PFAS concentrations in the aqueous phase. The authors investigated the sorption of perfluoroalkyl carboxylates, perfluoroalkyl sulfonates, perfluoroalkyl phosphonic acids, perfluoroalkyl phosphinic acids (PFPiAs), polyfluoroalkyl phosphate monoesters, polyfluoroalkyl phosphate diesters (diPAPs), fluorotelomer sulfonates, and perfluorooctane sulfonamide on filtration media. The effects of concentration (3 spiking levels), filter media (4 types), matrix (4 matrices), and compound structure on sorption are reported. Glass fiber filtration resulted in the least sorption, whereas polytetrafluoroethylene filters resulted in the most sorption (up to 98%). Analyte concentration had no significant effect. Sorption was generally consistent across matrix types except for samples affected by aqueous film forming foam deployment, which displayed high sorption of PFOS on nylon filters. Sorption usually increased with an increasing number of carbon or fluorine atoms and was most pronounced for PFPiAs and diPAPs (30–75% sorption). Overall, glass fiber filters are more recommended than nylon filters in environmental samples when phase separation is required. Use of filtration media for PFAS must be preceded by matrix-specific testing to account for unpredictable effects. (C)2014 SETAC

  3. Comparison of testing methods for particulate filters

    International Nuclear Information System (INIS)

    Ullmann, W.; Przyborowski, S.

    1983-01-01

    Four testing methods for particulate filters were compared by using the test rigs of the National Board of Nuclear Safety and Radiation Protection: 1) Measurement of filter penetration P as a function of particle size d by using a polydisperse NaC1 test aerosol and a scintillation particle counter; 2) Modified sodium flame test for measurement of total filter penetration P for various polydisperse NaC1 test aerosols; 3) Measurement of total filter penetration P for a polydisperse NaC1 test aerosol labelled with short-lived radon daughter products; 4) Measurement of total filter penetration P for a special paraffin oil test aerosol (oil fog test used in FRG according DIN 24 184, test aerosol A). The investigations were carried out on sheets of glass fibre paper (five grades of paper). Detailed information about the four testing methods and the used particle size distributions is given. The different results of the various methods are the base for the discussion of the most important parameters which influence the filter penetration P. The course of the function P=f(d) shows the great influence of the particle size. As expected there was also found a great dependence both from the test aerosol as well as from the principle and the measuring range of the aerosol-measuring device. The differences between the results of the various test methods are greater the lower the penetration. The use of NaCl test aerosol with various particle size distributions gives great differences for the respective penetration values. On the basis of these results and the values given by Dorman conclusions are made about the investigation of particulate filters both for the determination of filter penetration P as well as for the leak test of installed filters

  4. Thermally controlled mid-IR band-gap engineering in all-glass chalcogenide microstructured fibers: a numerical study

    DEFF Research Database (Denmark)

    Barh, Ajanta; Varshney, Ravi K.; Pal, Bishnu P.

    2017-01-01

    Presence of photonic band-gap (PBG) in an all-glass low refractive index (RI) contrast chalcogenide (Ch) microstructured optical fibers (MOFs) is investigated numerically. The effect of external temperature on the position of band-gap is explored to realize potential fiber-based wavelength filters....... Then the temperature sensitivity of band-gaps is investigated to design fiber-based mid-IR wavelength filters/sensors....

  5. Role of short-wavelength filtering lenses in delaying myopia progression and amelioration of asthenopia in juveniles

    Directory of Open Access Journals (Sweden)

    Hai-Lan Zhao

    2017-08-01

    Full Text Available AIM: To evaluate the positive effects of blue-violet light filtering lenses in delaying myopia and relieving asthenopia in juveniles. METHODS: Sixty ametropia juveniles (aged range, 11-15y were randomized into two groups: the test group (30 children, 60 eyes, wearing blue-violet light filtering lenses; and the control group (30 children, 60 eyes, wearing ordinary aspherical lenses. Baseline refractive power of the affected eyes and axial length of the two groups was recorded. After 1-year, the patients underwent contrast sensitivity (glare and non-glare under bright and dark conditions, accommodation-related testing, asthenopia questionnaire assessment, and adverse reaction questionnaire assessment. RESULTS: After 1y of wearing the filtering lenses, changes in refractive power and axial length were not significantly different between the two groups (P>0.05. Under bright conditions, the contrast sensitivities at low and medium-frequency grating (vision angles of 6.3°, 4.0°, and 2.5° with glare in the test group were significantly higher than in the control group (P0.05. In the test group, the amplitude of accommodation, accommodative lag, and accommodative sensitivity of patients wearing glasses for 6 and 12mo were significantly elevated (P0.05, and the asthenopia grating was not significantly decreased (P>0.05. In addition, after wearing glasses for 6 to 12mo, the asthenopia grating of patients in the test group decreased significantly compared with the control group (P0.05. CONCLUSION: A 1-year follow-up reveal that compare with ordinary glasses, short-wavelength filtering lenses (blue/violet-light filters increase the low- and medium-frequency contrast sensitivity under bright conditions and improved accommodation. They effectively relieved asthenopia without severe adverse reactions, suggesting potential for clinical application. However, no significant advantages in terms of refractive power or axial length progression were found compared

  6. [Preference for etanercept pen versus syringe in patients with chronic arthritis. Nurse education workshop].

    Science.gov (United States)

    Garcia-Diaz, Silvia; Girabent-Farrés, Montserrat; Roig-Vilaseca, Daniel; Reina, Delia; Cerdà, Dacia; González, Marina; Torrente-Segarra, Vicenç; Fíguls, Ramon; Corominas, Hèctor

    2013-01-01

    The aims of this study are to evaluate the level of fear of post-injection pain prior to the administration, the difficulty in handling the device, and the level of satisfaction of patients using a pre-filled syringe versus an etanercept pen, as well as to evaluate the usefulness of the training given by nursing staff prior to starting with the pen, and the preferences of patients after using both devices. A prospective study was designed to follow-up a cohort of patients during a 6 months period. The data was collected using questionnaires and analyzed with SPSS 18.00. Rank and McNemar tests were performed. Statistical significance was pre-set at an α level of 0.05. A total of 29 patients were included, of whom 69% female, and with a mean age 52.5±10.9 years. Of these, 48% had rheumatoid arthritis, 28% psoriatic arthritis, 21% ankylosing spondylitis, and 3% undifferentiated spondyloarthropathy. There were no statistically significant differences either with the fear or pain or handling of the device between the syringe and the pen (P=.469; P=.812; P=.169 respectively). At 6 months, 59% of patients referred to being satisfied or very satisfied with the pen. Almost all (93%) found useful or very useful the training given by nursing staff prior to using the pen, and 55% preferred the pen over the pre-filled syringe. The etanercept pen is another subcutaneous device option for patients with chronic arthritis. According to the present study, nursing educational workshops before starting this therapy are recommended. Copyright © 2012 Elsevier España, S.L. All rights reserved.

  7. A two-stage procedure for determining unsaturated hydraulic characteristics using a syringe pump and outflow observations

    DEFF Research Database (Denmark)

    Wildenschild, Dorthe; Jensen, Karsten Høgh; Hollenbeck, Karl-Josef

    1997-01-01

    A fast two-stage methodology for determining unsaturated flow characteristics is presented. The procedure builds on direct measurement of the retention characteristic using a syringe pump technique, combined with inverse estimation of the hydraulic conductivity characteristic based on one......-step outflow experiments. The direct measurements are obtained with a commercial syringe pump, which continuously withdraws fluid from a soil sample at a very low and accurate how rate, thus providing the water content in the soil sample. The retention curve is then established by simultaneously monitoring......-step outflow data and the independently measured retention data are included in the objective function of a traditional least-squares minimization routine, providing unique estimates of the unsaturated hydraulic characteristics by means of numerical inversion of Richards equation. As opposed to what is often...

  8. Optical Protection Filters for Harmful Laser Beams and UV Radiation

    Science.gov (United States)

    Azim M., Osama A.

    2007-02-01

    Due to the rapid growth of radiation protection applications in various devices and instruments, it is essential to use suitable filters for eye protection of the personal working in the radiation field. Different protection filters were produced to protect from four laser beam wavelengths (at 532nm, 632.8nm, 694nm and 1064nm) and block three UV bands (UVA, UVB, and UVC). The design structure of the required dielectric multilayer filters used optical thin film technology. The computer analyses of the multilayer filter formulas were prepared using Macleod Software for the production filter processes. The deposition technique was achieved on optical substrates (Glass BK-7 and Infrasil 301) by dielectric material combinations including Dralo (mixture of oxides TiO2/Al2O3), and Lima (mixture of oxides SiO2/Al2O3); deposition by an electron beam gun. The output transmittance curves for both theoretical and experimental values of all filters are presented. To validate the suitability for use in a `real world', rather than laboratory test application, full environmental assessment was also carried out. These filters exhibited high endurance after exposing them to the durability tests (adhesion, abrasion resistance and humidity) according to military standards MIL-C-675C and MIL-C-48497A.

  9. Optical Protection Filters for Harmful Laser Beams and UV Radiation

    International Nuclear Information System (INIS)

    Azim M, Osama A.

    2007-01-01

    Due to the rapid growth of radiation protection applications in various devices and instruments, it is essential to use suitable filters for eye protection of the personal working in the radiation field. Different protection filters were produced to protect from four laser beam wavelengths (at 532nm, 632.8nm, 694nm and 1064nm) and block three UV bands (UVA, UVB, and UVC). The design structure of the required dielectric multilayer filters used optical thin film technology. The computer analyses of the multilayer filter formulas were prepared using Macleod Software for the production filter processes. The deposition technique was achieved on optical substrates (Glass BK-7 and Infrasil 301) by dielectric material combinations including Dralo (mixture of oxides TiO2/Al2O3), and Lima (mixture of oxides SiO2/Al2O3); deposition by an electron beam gun. The output transmittance curves for both theoretical and experimental values of all filters are presented. To validate the suitability for use in a 'real world', rather than laboratory test application, full environmental assessment was also carried out. These filters exhibited high endurance after exposing them to the durability tests (adhesion, abrasion resistance and humidity) according to military standards MIL-C-675C and MIL-C-48497A

  10. Direct conversion of plutonium metal, scrap, residue, and transuranic waste to glass

    International Nuclear Information System (INIS)

    Forsberg, C.W.; Beahm, E.C.; Parker, G.W.; Malling, J.F.; Rudolph, J.

    1995-01-01

    A method for the direct conversion of metals, ceramics, organics, and amorphous solids to borosilicate glass has been invented. The process is called the Glass Material Oxidation and Dissolution System (GMODS). Traditional glass-making processes can convert only oxide materials to glass. However, many wastes contain complex mixtures of metals, ceramics, organics, and amorphous solids. Conversion of such mixtures to oxides followed by their conversion to glass is often impractical. GMODS may create a practical method to convert such mixtures to glass. Plutonium-containing materials (PCMS) exist in many forms, including metals, ceramics, organics, amorphous solids, and mixtures thereof. These PCMs vary from plutonium metal to filters made of metal, organic binders, and glass fibers. For storage and/or disposal of PCMS, it is desirable to convert PCMs to borosilicate glass. Borosilicate glass is the preferred repository waste form for high-level waste (HLW) because of its properties. PCMs converted to a transuranic borosilicate homogeneous glass would easily pass all waste acceptance and storage criteria. Conversion of PCMs to a glass would also simplify safeguards by conversion of heterogeneous PCMs to homogeneous glass. Thermodynamic calculations and proof-of-principle experiments on the GMODS process with cerium (plutonium surrogate), uranium, stainless steel, aluminum, Zircaloy-2, and carbon were successfully conducted. Initial analysis has identified potential flowsheets and equipment. Major unknowns remain, but the preliminary data suggests that GMODS may be a major new treatment option for PCMs

  11. Further development of the cleanable steel HEPA filter, cost/benefit analysis, and comparison with competing technologies

    Energy Technology Data Exchange (ETDEWEB)

    Bergman, W.; Lopez, R.; Wilson, K. [Lawrence Livermore National Lab., CA (United States)] [and others

    1997-08-01

    We have made further progress in developing a cleanable steel fiber HEPA filter. We fabricated a pleated cylindrical cartridge using commercially available steel fiber media that is made with 1 {mu}m stainless steel fibers and sintered into a sheet form. Test results at the Department of Energy (DOE) Filter Test Station at Oak Ridge show the prototype filter cartridge has 99.99% efficiency for 0.3 {mu}m dioctyl phthalate (DOP) aerosols and a pressure drop of 1.5 inches. Filter loading and cleaning tests using AC Fine dust showed the filter could be repeatedly cleaned using reverse air pulses. Our analysis of commercially optimized filters suggest that cleanable steel HEPA filters need to be made from steel fibers less than 1{mu}m, and preferably 0.5 {mu}m, to meet the standard HEPA filter requirements in production units. We have demonstrated that 0.5 {mu}m steel fibers can be produced using the fiber bundling and drawing process. The 0.5 {mu}m steel fibers are then sintered into small filter samples and tested for efficiency and pressure drop. Test results on the sample showed a penetration of 0.0015 % at 0.3 {mu}m and a pressure drop of 1.15 inches at 6.9 ft/min (3.5 cm/s) velocity. Based on these results, steel fiber media can easily meet the requirements of 0.03 % penetration and 1.0 inch of pressure drop by using less fibers in the media. A cost analysis of the cleanable steel HEPA filter shows that, although the steel HEPA filter costs much more than the standard glass fiber HEPA filter, it has the potential to be very cost effective because of the high disposal costs of contaminated HEPA filters. We estimate that the steel HEPA filter will save an average of $16,000 over its 30 year life. The additional savings from the clean-up costs resulting from ruptured glass HEPA filters during accidents was not included but makes the steel HEPA filter even more cost effective. 33 refs., 28 figs., 1 tab.

  12. Evaluation of Physical Capture Efficiency and Disinfection Capability of a Novel Iodinated Filter Medium

    National Research Council Canada - National Science Library

    Ratnesar, Shanna; Wu, Chang-Yu; Wander, Joe; Lundgren, Dale; Farrah, Sam; Wanakule, Prinda; Blackburn, Matthew; Lan, Mei-Fang

    2006-01-01

    ...% that of the glass-fiber HEPA filter (0.0054 in H2O/(in/min) vs 0.065 in H2O/(in/min)). Biological disinfection by the medium was evaluated using Micrococcus luteus and Echerichia coli vegetative bacterial cells...

  13. Development of nuclear safety class filter elements with long life and high quality

    International Nuclear Information System (INIS)

    Zhang Jinghua

    2009-04-01

    This paper describes the development on nuclear safety class filter elements with long life and high quality used for collecting radioactive contaminants, fragments of resin and impurities in primary systems of NPPs. The filter elements made of glass fibre elements are used for PWR, and of paper elements are used for PHWR. During the research, a series of tests for optimization were performed for selection of filter material and the improvement of binder. The flow rate and comprehensive performance have been measured in simulated conditions. The result shows that the application requirements for operational NPPs can be met, and the reliability and safety of the frame are also be verified. The comprehensive performance of the filter elements is equivalent to that of oversea similar products. The products have been used in NPPs in operation. (authors)

  14. Analysis of Hypodermic Needles and Syringes for the Presence of Blood and Polydimethylsiloxane (Silicone) Utilizing Microchemical Tests and Infrared Spectroscopy.

    Science.gov (United States)

    Crowe, John B; Lanzarotta, Adam; Witkowski, Mark R; Andria, Sara E

    2015-07-01

    Suspect hypodermic needles and syringes were seized from an unlicensed individual who was allegedly injecting patients with silicone (polydimethylsiloxane [PDMS]) for cosmetic enhancement. Since control syringe barrels and needles often contain an interfering PDMS lubricant, a risk for false positives of foreign PDMS exists. The focus of this report was to minimize this risk and determine a quick and reliable test for the presence of blood in PDMS matrices. Using ATR-FT-IR spectroscopy, the risk for false-positive identification of foreign PDMS was reduced by (i) overfilling the sampling aperture to prevent spectral distortions and (ii) sampling a region of the suspect syringe/needle assembly where manufacturer-applied PDMS is not typically located. Analysis for blood indicated that the Teichman microchemical test was effective for detecting blood in the presence of PDMS. Overall, detecting PDMS established intent and detecting blood established that the needle containing the PDMS had been used for injection. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.

  15. Investigation of different types of filters for atmospheric trace elements analysis by three analytical techniques

    International Nuclear Information System (INIS)

    Ali, A.E.; Bacso, J.

    1996-01-01

    Different atmospheric aerosol samples were collected on three types of filters. Disks of both loaded and clean areas of each kind of filter were investigated by XRF, PIXE and Scanning Electron Microscope (SEM) methods. The blank concentration values of the elements Al, Si, P, S, Cl, K, Ca, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Br and Pb in the three types of filters are discussed. It is found that for trace elemental analysis, the Nuclepore membrane filters are the most suitable for sampling. These have much lower blank element concentration values than the glass fibres and ash free filters. It was found also that the PIXE method is a more reliable analytical technique for atmospheric aerosol particles than the other methods. (author). 20 refs., 3 figs., 3 tabs

  16. Solids loading evaluation for HB-line scrap recovery filters

    International Nuclear Information System (INIS)

    Crowder, M.L.

    2000-01-01

    The HB-Line Scrap Recovery facility uses wire screen filters to remove solids from plutonium-containing solutions transferred from the slab tank dissolvers. At times, the accumulation of solids is large enough to cause blinding (i.e., pluggage) of the filters. If the solids contain undissolved plutonium, significant accumulation of fissile material could impact operations. To address this potential issue, experiments were performed to define the minimum solids required to completely blind a filter. The solids loading experiments were performed by arranging 25- and 10-microm HB-Line filters in series to simulate the equipment in the scrap recovery process. Separate tests were performed using coarse and fine glass frit and cerium oxide powder suspended in 35 wt% sodium nitrate solution using a small turbine mixer. The solution and solids were transferred from a reservoir through the filter housings by vacuum. In each case, the 25-microm filter blinded first and was full of wet cake. After drying and accounting for the sodium nitrate in the filter cake, the following results were obtained. The results of the solids loading tests demonstrated that at least 800 g of solids accumulated in the filter housing before flow stopped. The actual amount of collected material was dependent upon the physical properties of the solids such as density and particle size. The mass of solids collected by the blinded 25-microm filter increased when successively finer solids were used in the experiments. Based on these results, one should anticipate that filters in the HB-Line Scrap Recovery Facility have the potential to collect similar quantities of material before transfer of solution from the dissolvers is severely impacted

  17. Organic Extractives from Mentha spp. Honey and the Bee-Stomach: Methyl Syringate, Vomifoliol, Terpenediol I, Hotrienol and Other Compounds

    Directory of Open Access Journals (Sweden)

    Igor Jerković

    2010-04-01

    Full Text Available The GC and GC/MS analyses of the solvent organic extractive from the stomach of the bees, having collected Mentha spp. nectar, revealed the presence of methyl syringate (6.6%, terpendiol I (5.0% and vomifoliol (3.0% that can be attributed to the plant origin. Other major compounds from the bee-stomach were related to the composition of cuticular waxes and less to pheromones. Organic extractivesfrom Mentha spp. honey were obtained by solvent-free headspace solid-phase microextraction (HS-SPME and ultrasonic solvent extraction (USE and analyzed by GC and GC/MS. The major honey headspace compounds were hotrienol (31.1%–38.5%, 2-methoxy-4-methylphenol (0.5–6.0%, cis- and trans-linalool oxides (0.9–2.8%, linalool (1.0–3.1% and neroloxide (0.9–1.9%. Methyl syringate was the most abundant compound (38.3-56.2% in the honey solvent extractives followed by vomifoliol (7.0–26.6%. Comparison of the honey organic extractives with the corresponding bee-stomach extractive indicated that methyl syringate and vomofoliol were transferred to the honey while terpendiol I was partially transformed to hotrienol in ripened honey.

  18. The Study on the Alteration of Simulated HLLW Glass in Aqueous Media by Inverse Gas Chromatography

    International Nuclear Information System (INIS)

    Zhang, Zhentao; Gan, Xueying; Yuan, Wenyi; Wang, Lei; Xing, Haiqing; Balard, Henri

    2008-01-01

    There exist webs of fissures inside the glass block accessible to underground water and theses fissures will influence the alteration of the glass significantly. It is very necessary to study the fissure surface properties of the glass under deep geological conditions. The alteration tests were conducted using the simulated high level radioactive glass powder immersed in Beishan (candidate disposal site) underground water with S/V ratio of 8000 m -1 at 150 deg. C and 90 deg. C for different periods. After immersion, the glass powder was filtered and dried at 120 deg. C for 3 hours. The surface properties of the dried glass powder were evaluated by inverse chromatography. The results showed that the specific surface area of the glass increases abruptly at the beginning of immersion and then increase slowly afterwards. At higher immersion temperature, the secondary phase is condensing crystals; at the lower immersion temperature, the secondary phases were loosely 'islands' with cracks or fissures. (authors)

  19. Implementation Study of Patient-Ready Syringes Containing 25 mg/mL Methotrexate Solution for Use in Treating Ectopic Pregnancy

    Directory of Open Access Journals (Sweden)

    R. Respaud

    2014-01-01

    Full Text Available Background. Ectopic pregnancy (EP is a significant cause of morbidity and mortality during the first trimester of pregnancy. Small unruptured tubal pregnancies can be treated medically with a single dose of methotrexate (MTX. Objective. The aim of this study was to evaluate the stability of a 25 mg/mL solution of MTX to devise a secure delivery circuit for the preparation and use of this medication in the management of EP. Method. MTX solutions were packaged in polypropylene syringes, stored over an 84-day period, and protected from light either at +2 to +8°C or at 23°C. We assessed the physical and chemical stability of the solutions at various time points over the storage period. A pharmaceutical delivery circuit was implemented that involved the batch preparation of MTX syringes. Results. We show that 25 mg/mL MTX solutions remain stable over an 84-day period under the storage conditions tested. Standard doses were prepared, ranging from 50 mg to 100 mg. The results of this study suggest that MTX syringes can be prepared in advance by the pharmacy, ready to be dispensed at any time that a diagnosis of EP is made. Conclusion. The high stability of a 25 mg/mL MTX solution in polypropylene syringes makes it possible to implement a flexible and cost-effective delivery circuit for ready-to-use preparations of this drug, providing 24-hour access and preventing treatment delays.

  20. Preparation of RF-(VM-SiO2n-RF/AM-Cellu Nanocomposites, and Use Thereof for the Modification of Glass and Filter Paper Surfaces: Creation of a Glass Thermoresponsive Switching Behavior and an Efficient Separation Paper Membrane

    Directory of Open Access Journals (Sweden)

    Hideo Sawada

    2017-03-01

    Full Text Available Fluoroalkyl end-capped vinyltrimethoxysilane oligomeric silica/alkyl-modified cellulose (AM-Cellu nanocomposites [RF-(CH2-CHSiO2n-RF/AM-Cellu; n = 2, 3; RF = CF(CF3OC3F7] were prepared by the sol-gel reactions of the corresponding oligomer [RF-(CH2-CHSi(OMe3n-RF] in the presence of AM-Cellu. The nanocomposites thus obtained were applied to the surface modification of glass to exhibit a highly oleophobic/superhydrophilic characteristic on the modified surface at 20 °C. Interestingly, a temperature dependence of contact angle values of dodecane and water was observed on the modified surface at 20~70 °C, and the dodecane contact angle values were found to decrease with increasing the temperatures from 20 to 70 °C to provide from highly oleophobic to superoleophilic characteristics on the surface. On the other hand, the increase of the water contact angle values was observed with the increase in the temperatures under similar conditions to supply superhydrophilic to superhydrophobic characteristics on the modified surface. The corresponding nanocomposites were also applied to the surface modification of the filter paper under similar conditions to afford a superoleophilic/superhydrophobic characteristic on the surface. It was demonstrated that the modified filter paper is effective for the separation membrane for W/O emulsion to isolate the transparent colorless oil.

  1. Recycle Glass in Foam Glass Production

    DEFF Research Database (Denmark)

    Petersen, Rasmus Rosenlund; König, Jakob; Yue, Yuanzheng

    The foam glass industry turn recycle glass into heat insulating building materials. The foaming process is relative insensitive to impurities in the recycle glass. It is therefore considered to play an important role in future glass recycling. We show and discuss trends of use of recycled glasses...... in foam glass industry and the supply sources and capacity of recycle glass....

  2. Ultrathin metal-semiconductor-metal resonator for angle invariant visible band transmission filters

    International Nuclear Information System (INIS)

    Lee, Kyu-Tae; Seo, Sungyong; Yong Lee, Jae; Jay Guo, L.

    2014-01-01

    We present transmission visible wavelength filters based on strong interference behaviors in an ultrathin semiconductor material between two metal layers. The proposed devices were fabricated on 2 cm × 2 cm glass substrate, and the transmission characteristics show good agreement with the design. Due to a significantly reduced light propagation phase change associated with the ultrathin semiconductor layer and the compensation in phase shift of light reflecting from the metal surface, the filters show an angle insensitive performance up to ±70°, thus, addressing one of the key challenges facing the previously reported photonic and plasmonic color filters. This principle, described in this paper, can have potential for diverse applications ranging from color display devices to the image sensors.

  3. Experimental Investigation of In Situ Cleanable or Regenerative Filters for High Level Radioactive Waste Tanks

    International Nuclear Information System (INIS)

    Adamson, D.J.

    2000-01-01

    The Westinghouse Savannah River Company, located at the Savannah River Site (SRS) in Aiken, South Carolina, is currently testing two types of filter media for application as in situ regenerable/cleanable filters on high-level radioactive liquid waste tanks. Each of the 1.3 million-gallon tanks is equipped with an exhaust ventilation system to provide tank ventilation and to maintain the tank contents at approximately 1-in. water gauge vacuum to prevent the release of radioactive material to the environment. These systems are equipped with conventional, disposable, glass-fiber, High Efficiency Particulate Air (HEPA) filters that require frequent removal, replacement, and disposal. The need for routine replacements is often caused by accelerated filter loading due to the moist operating environment, which structurally weakens the filter media. This is not only costly, but subjects site personnel to radiation exposure and possible contamination. The types of filter media tested, as part of a National Energy Technology Laboratory procurement, were sintered metal and monolith ceramic. The media were subjected to a hostile environment to simulate conditions that challenge the tank ventilation systems. The environment promoted rapid filter plugging to maximize the number of filter loading/cleaning cycles that would occur in a specified period of time. The filters were challenged using non-radioactive, simulated high level waste materials and atmospheric dust, as these materials are most responsible for filter pluggage in the field. The filters were cleaned/regenerated in situ using an aqueous solution of dilute (10% volume) nitric acid. The study found that both filter media were insensitive to high humidity or moisture conditions and were easily cleaned in situ. The filters regenerated to approximately clean filter status even after numerous plugging and cleaning cycles. The filters were leak tested using poly alpha olefin aerosol at the beginning, middle, and end of the

  4. The impact of metallic filter media on HEPA filtration

    International Nuclear Information System (INIS)

    Chadwick, Chris; Kaufman, Seth

    2006-01-01

    Traditional HEPA filter systems have limitations that often prevent them from solving many of the filtration problems in the nuclear industry; particularly in applications where long service or storage life, high levels of radioactivity, dangerous decomposition products, chemical aggression, organic solvents, elevated operating temperatures, fire resistance and resistance to moisture are issues. This paper addresses several of these matters of concern by considering the use of metallic filter media to solve HEPA filtration problems ranging from the long term storage of transuranic waste at the WIPP site, spent and damaged fuel assemblies, in glove box ventilation and tank venting to the venting of fumes at elevated temperatures from incinerators, vitrification processes and conversion and sintering furnaces as well as downstream of iodine absorbers in gas cooled reactors in the UK. The paper reviews the basic technology, development, performance characteristics and filtration efficiency, flow versus differential pressure, cleanability and costs of sintered metal fiber in comparison with traditional resin bonded glass fiber filter media and sintered metal powder filter media. Examples of typical filter element and system configurations and applications will be presented The paper will also address the economic case for installing self cleaning pre-filtration, using metallic media, to recover the small volumes of dust that would otherwise blind large volumes of final disposable HEPA filters, thus presenting a route to reduce ultimate disposal volumes and secondary waste streams. (authors)

  5. Nanostructure analysis of friction welded Pd-Ni-P/Pd-Cu-Ni-P metallic glass interface

    International Nuclear Information System (INIS)

    Ohkubo, T.; Shoji, S.; Kawamura, Y.; Hono, K.

    2005-01-01

    Friction welded Pd 40 Ni 40 P 20 /Pd 40 Cu 30 Ni 10 P 20 metallic glass interface has been characterized by energy filtering transmission electron microscopy. The interface is fully amorphous with a gradual compositional change of Cu and Ni in the range of 30 nm. By annealing above T g , the interdiffusion of Cu and Ni progressed in the supercooled liquid region, and the crystallization occurred from the Pd 40 Ni 40 P 20 glass

  6. Simultaneous extraction and determination of albendazole and triclabendazole by a novel syringe to syringe dispersive liquid phase microextraction-solidified floating organic drop combined with high performance liquid chromatography.

    Science.gov (United States)

    Asadi, Mohammad; Dadfarnia, Shayessteh; Haji Shabani, Ali Mohammad

    2016-08-17

    A syringe to syringe dispersive liquid phase microextraction-solidified floating organic drop was introduced and used for the simultaneous extraction of trace amounts of albendazole and triclabendazole from different matrices. The extracted analytes were determined by high performance liquid chromatography along with fluorescence detection. The analytical parameters affecting the microextraction efficiency including the nature and volume of the extraction solvent, sample volume, sample pH, ionic strength and the cycles of extraction were optimized. The calibration curves were linear in the range of 0.1-30.0 μg L(-1) and 0.2-30.0 μg L(-1) with determination coefficients of 0.9999 and 0.9998 for albendazole and triclabendazole respectively. The detection limits defined as three folds of the signal to noise ratio were found to be 0.02 μg L(-1) for albendazole and 0.06 μg L(-1) for triclabendazole. The inter-day and intra-day precision (RSD%) for both analytes at three concentration levels (0.5, 2.0 and 10.0 μg L(-1)) were in the range of 6.3-10.1% and 5.0-7.5% respectively. The developed method was successfully applied to determine albendazole and triclabendazole in water, cow milk, honey, and urine samples. Copyright © 2016. Published by Elsevier B.V.

  7. Correction factors of commercial radionuclide calibrators for several measurement geometries of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Correia, Amanda Ribeiro

    2011-01-01

    In order to reach therapy and diagnosis objectives, the activity must be determined with high accuracy to administer a radiopharmaceutical to a patient. Initially, a glass vial with the radiopharmaceutical is placed into the radionuclide calibrator to determine its activity. Subsequently, an aliquot is transferred to a syringe and again its activity is measured on the calibrator before being administered to the patient. The glass vial and the syringe are different in many aspects as the calibration factors too, which may cause incorrect activities administered to the patient. This study aims to determine the correction factors, as well as the values of the uncertainties associated to two distinct models of calibrators: one that uses ionization chamber and another Geiger-Mueller as detectors. The radionuclides chosen were 99 Tc m and 123 1 and the containers were glass vials (type lOR and P6) and plastic syringes of 3 and 5 mL. The correction factors for each type of vials or syringe were determined as a function of volume and type of calibrator. Activity measurements comparison was also made involving several radionuclide calibrators of different models belonging to four nuclear medicine hospitals and to National Metrology Laboratory of lionizing Radiation (LNMRI). In the measurements of activity values larger than allowed by CNEN NN-3.05 norm, results have shown deviations for syringes in calibrator with Geiger-Mueller detectors and for both radionuclides. (author)

  8. Development and evaluation of a HEPA filter for increased strength and resistance to elevated temperature

    International Nuclear Information System (INIS)

    Gilbert, H.; Bergman, W.; Fretthold, J.K.

    1992-01-01

    We have developed an improved HEPA filter for increased strength and resistance to elevated temperature to improve the reliability of HEPA filters under accident conditions. The improvements to the HEPA filter consist of a silicone rubber sealant and a new HEPA medium reinforced with a glass cloth. Several prototype filters were built and evaluated for temperature and pressure resistance and resistance to rough handling. The temperature resistance test consisted of exposing the HEPA filter to 1,000 scan at 700 degrees F for five minutes. The pressure resistance test consisted of exposing the HEPA filter to a differential pressure of 10 in. w.g. using a water saturated air flow at 95 degrees F. For the rough handling test, we used a vibrating machine designated the Q110. DOP filter efficiency tests were performed before and after each of the environmental tests. In addition to following the standard practice of using a separate new filter for each environmental test, we also subjected the same filter to the elevated temperature test followed by the pressure resistance test. The efficiency test results show that the improved HEPA filter is significantly better than the standard HEPA filter

  9. Computer-Aided Segmentation and Volumetry of Artificial Ground-Glass Nodules at Chest CT

    NARCIS (Netherlands)

    Scholten, Ernst Th.; Jacobs, Colin; van Ginneken, Bram; Willemink, Martin J.; Kuhnigk, Jan-Martin; van Ooijen, Peter M. A.; Oudkerk, Matthijs; Mali, Willem P. Th. M.; de Jong, Pim A.

    OBJECTIVE. The purpose of this study was to investigate a new software program for semiautomatic measurement of the volume and mass of ground-glass nodules (GGNs) in a chest phantom and to investigate the influence of CT scanner, reconstruction filter, tube voltage, and tube current. MATERIALS AND

  10. The case for improved HEPA-filter mechanical performance standards revisited

    Energy Technology Data Exchange (ETDEWEB)

    Ricketts, C.I.; Smith, P.R. [New Mexico State Univ., Las Cruces, NM (United States)

    1997-08-01

    Under benign operating conditions, High Efficiency Particulate Air (HEPA) filter units serve as reliable and relatively economical components in the air cleaning systems of nuclear facilities worldwide. Despite more than four decades of filter-unit evaluation and improvements, however, the material strength characteristics of the glass fiber filter medium continue to ultimately limit filter functional reliability. In worst-case scenarios involving fire suppression, loss-of-coolant accidents (LOCA`s), or exposure to shock waves or tornado induced flows, rupture of the filter medium of units meeting current qualification standards cannot be entirely ruled out. Even under so-called normal conditions of operation, instances of filter failure reported in the literature leave open questions of filter-unit reliability. Though developments of filter units with improved burst strengths have been pursued outside the United States, support for efforts in this country has been comparatively minimal. This despite user requests for filters with greater moisture resistance, for example. Or the fact that conventional filter designs result in not only the least robust component to be found in a nuclear air cleaning system, but also the one most sensitive to the adverse effects of conditions deviating from those of normal operation. Filter qualification-test specifications of current codes, standards, and regulatory guidelines in the United States are based primarily upon research performed in a 30-year period beginning in the 1950`s. They do not seem to reflect the benefits of the more significant developments and understanding of filter failure modes and mechanisms achieved since that time. One overseas design, based on such knowledge, has proven reliability under adverse operating conditions involving combined and serial challenges. Its widespread use, however, has faltered on a lack of consensus in upgrading filter performance standards. 34 refs., 2 figs., 3 tabs.

  11. Deposition of a conductive near-infrared cutoff filter by radio-frequency magnetron sputtering

    International Nuclear Information System (INIS)

    Lee, Jang-Hoon; Lee, Seung-Hyu; Yoo, Kwang-Lim; Kim, Nam-Young; Hwangbo, Chang Kwon

    2002-01-01

    We have designed a conductive near-infrared (NIR) cutoff filter for display application, i.e., a modified low-emissivity filter based on the three periods of the basic design of [TiO2|Ti|Ag| TiO2] upon a glass substrate and investigated the optical, structural, chemical, and electrical properties of the conductive NIR cutoff filter prepared by a radio frequency magnetron sputtering system. The results show that the average transmittance is 61.1% in the visible, that the transmittance in the NIR is less than 6.6%, and that the sheet resistance and emissivity are 0.9 Ω/□ (where □ stands for a square film) and 0.012, respectively, suggesting that the conductive NIR cutoff filter can be employed as a shield against the hazard of electromagnetic waves as well as to cut off the NIR

  12. Lab-In-Syringe automation of stirring-assisted room-temperature headspace extraction coupled online to gas chromatography with flame ionization detection for determination of benzene, toluene, ethylbenzene, and xylenes in surface waters.

    Science.gov (United States)

    Horstkotte, Burkhard; Lopez de Los Mozos Atochero, Natalia; Solich, Petr

    2018-06-22

    Online coupling of Lab-In-Syringe automated headspace extraction to gas chromatography has been studied. The developed methodology was successfully applied to surface water analysis using benzene, toluene, ethylbenzene, and xylenes as model analytes. The extraction system consisted of an automatic syringe pump with a 5 mL syringe into which all solutions and air for headspace formation were aspirated. The syringe piston featured a longitudinal channel, which allowed connecting the syringe void directly to a gas chromatograph with flame ionization detector via a transfer capillary. Gas injection was achieved via opening a computer-controlled pinch valve and compressing the headspace, upon which separation was initialized. Extractions were performed at room temperature; yet sensitivity comparable to previous work was obtained by high headspace to sample ratio V HS /V Sample of 1.6:1 and injection of about 77% of the headspace. Assistance by in-syringe magnetic stirring yielded an about threefold increase in extraction efficiency. Interferences were compensated by using chlorobenzene as an internal standard. Syringe cleaning and extraction lasting over 10 min was carried out in parallel to the chromatographic run enabling a time of analysis of <19 min. Excellent peak area repeatabilities with RSD of <4% when omitting and <2% RSD when using internal standard corrections on 100 μg L -1 level were achieved. An average recovery of 97.7% and limit of detection of 1-2 μg L -1 were obtained in analyses of surface water. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Silver metaphosphate glass wires inside silica fibers--a new approach for hybrid optical fibers.

    Science.gov (United States)

    Jain, Chhavi; Rodrigues, Bruno P; Wieduwilt, Torsten; Kobelke, Jens; Wondraczek, Lothar; Schmidt, Markus A

    2016-02-22

    Phosphate glasses represent promising candidates for next-generation photonic devices due to their unique characteristics, such as vastly tunable optical properties, and high rare earth solubility. Here we show that silver metaphosphate wires with bulk optical properties and diameters as small as 2 µm can be integrated into silica fibers using pressure-assisted melt filling. By analyzing two types of hybrid metaphosphate-silica fibers, we show that the filled metaphosphate glass has only negligible higher attenuation and a refractive index that is identical to the bulk material. The presented results pave the way towards new fiber-type optical devices relying on metaphosphate glasses, which are promising materials for applications in nonlinear optics, sensing and spectral filtering.

  14. Product consistency leach tests of Savannah River Site radioactive waste glasses

    International Nuclear Information System (INIS)

    Bibler, N.E.; Bates, J.K.

    1990-01-01

    The product consistency test (PCT) is a glass leach test developed at the Savannah River Site (SRS) to confirm the durability of radioactive nuclear waste glasses that will be produced in the Defense Waste Processing Facility. The PCT is a seven day, crushed glass leach test in deionized water at 90C. Final leachates are filtered and acidified prior to analysis. To demonstrate the reproducibility of the PCT when performed remotely, SRS and Argonne National Laboratory have performed the PCT on samples of two radioactive glasses. The tests were also performed to compare the releases of the radionuclides with the major nonradioactive glass components and to determine if radiation from the glass was affecting the results of the PCT. The test was performed in triplicate at each laboratory. For the major soluble elements, B, Li, Na, and Si, in the glass, each investigator obtained relative precisions in the range 2-5% in the triplicate tests. This range indicates good precision for the PCT when performed remotely with master slave manipulators in a shielded cell environment. When the results of the two laboratories were compared to each other, the agreement was within 20%. Normalized concentrations for the nonradioactive and radioactive elements in the PCT leachates measured at both facilities indicated that the radionuclides were released from the glass slower than the major soluble elements in the glass. For both laboratories, the normalized releases for both glasses were in the general order Li ∼ B ∼ Na > Si > Cs - 137 > Sb - 125 < Sr - 90. The normalized releases for the major soluble elements and the final pH values in the tests with radioactive glass are consistent with those for nonradioactive glasses with similar compositions. This indicates that there was no significant effect of radiation on the results of the PCT

  15. A container closure system that allows for greater recovery of radiolabeled peptide compared to the standard borosilicate glass system

    International Nuclear Information System (INIS)

    Leece, Alicia K.; Heidari, Pedram; Yokell, Daniel L.; Mahmood, Umar

    2013-01-01

    Objectives: Often peptides used in synthesis of radiopharmaceutical PET tracers are lipophilic and adhere to the walls of container closure systems (CCS) such that costly peptide and product are not fully recoverable after synthesis occurs. This investigation compares a standard United States Pharmacopeia (USP) Type I borosilicate glass CCS to a cyclic polyolefin copolymer Crystal Zenith ® (CZ) CCS, for 68 Ga-chloride and 68 Ga-DOTATOC ([ 68 Ga] Ga-DOTA-D-Phe1-Tyr3-octreotide) retention in the reaction vial after labeling. Methods: 68 Gallium labeling of DOTATOC was conducted by adding 68 Ga-chloride, 2 M HEPES (4-(2-hydroxyethyl)piperazine-1-ethanesulfonic acid) or 0.75 M sodium acetate, and 1–30 µg of DOTATOC into the CZ or glass CCS. The reaction mixture was heated for 15 min and cooled to room temperature. The crude reaction mixture was then withdrawn via syringe, for final processing. The CCS was then assayed using a dose calibrator to determine the amount of retained 68 Ga-DOTATOC. Statistical significance was assessed using an unpaired Student's t-test. Results: In all experiments (n=72) with various amounts of peptide and different buffering systems, the CZ CCS retained less activity than the glass CCS. Using 2 M HEPES and 15 µg or 30 µg of DOTATOC, the CZ CCS retained approximately 10% less of the labeled DOTATOC compared to the glass CCS (p 68 Ga-chloride. Conclusion: For applications involving the labeling of peptides such as 68 Ga-DOTATOC, the CZ CCS compared to the glass CCS, results in an improved recovery of product. - Highlights: • We examined the adhesion of 68 Ga-DOTATOC to glass and CZ CCS. • The adhesion of the 68 Ga-DOTATOC was 10% less in CZ CCS compared to glass CCS. • Overall recovery of 68 Ga-DOTATOC reaction solution is higher in CZ CCS than glass CCS. • Adhesion to the CCS is due to 68 Ga-DOTATOC, not 68 Ga-chloride

  16. Viral Penetration of High Efficiency Particulate Air (HEPA) Filters

    Science.gov (United States)

    2007-02-01

    PVC tubing (Excelon® RNT,US Plastics, Lima , Ohio). Each path runs through a test article and thence through one AGI-30 all-glass impingers (Chemglass...a mechanical flow meter (Blue–White 400, Huntington Beach , California, or PMR1-101346, Cole– Parmer, Vernon Hills, Illinois). At the end of the...fibrous Filters." Air Pollution Control Association 30(4): 377-381. Leenders, G. J. M. and J. H. Stadhouders (1980s). "Effectiveness of HEPA

  17. Social marketing of low dead space syringes in Vietnam: findings from a 1-year pilot program in Hanoi, Thai Nguyen, and Ho Chi Minh City.

    Science.gov (United States)

    Huong, Ngo Thi Thanh; Mundy, Gary; Neukom, Josselyn; Zule, William; Tuan, Nguyen Minh; Tam, Nguyen Minh

    2015-05-30

    Although a growing body of evidence suggests that low dead space syringes may reduce the risk of human immunodeficiency virus (HIV) and Hepatitis C virus infection associated with sharing syringes among people who inject drugs, there is little evidence of effective approaches to motivate people who inject drugs (PWID) to shift from high to low dead space syringes. Using a mix of consumer and trade marketing approaches, informed by rapid assessments of both the syringe market and PWID preferences, practices, and behaviors in Hanoi and Ho Chi Minh City, Population Services International (PSI) Vietnam piloted an intervention to increase the use of low dead space syringes (LDSS) in the three provinces of Hanoi, Ho Chi Minh City, and Thai Nguyen, where an estimated 31% of PWID are HIV positive and 58% are living with hepatitis C virus (HCV). This paper provides a summary of the social marketing activities implemented and results achieved by PSI Vietnam during an initial 1-year pilot period from December 2012 to December 2013 in these three provinces to explore their effectiveness in motivating PWID to use low dead space syringes. We found major increases in sales of LDSS accompanied by increases in reported use and consistent use of LDSS among PWID in the three provinces included in the pilot program and a positive and independent association (odds ratio (OR) 21.08; 95% confidence interval (CI) 10.6-27.3) between LDSS use and exposure to social marketing activities. We also found that LDSS use had a stronger association with perceptions of LDSS product quality than with perceptions regarding LDSS potential to reduce HIV transmission risk and use. We conclude that social marketing interventions have an important role to play in widening access to and the use of LDSS for PWID, as they address the need for PWID to find LDSS when and where they need them and also promote the benefits of LDSS use to PWID. High coverage of these activities among PWID appears to be the key in

  18. Glass consistency and glass performance

    International Nuclear Information System (INIS)

    Plodinec, M.J.; Ramsey, W.G.

    1994-01-01

    Glass produced by the Defense Waste Processing Facility (DWPF) will have to consistently be more durable than a benchmark glass (evaluated using a short-term leach test), with high confidence. The DWPF has developed a Glass Product Control Program to comply with this specification. However, it is not clear what relevance product consistency has on long-term glass performance. In this report, the authors show that DWPF glass, produced in compliance with this specification, can be expected to effectively limit the release of soluble radionuclides to natural environments. However, the release of insoluble radionuclides to the environment will be limited by their solubility, and not glass durability

  19. Randomized, community-based pharmacy intervention to expand services beyond sale of sterile syringes to injection drug users in pharmacies in New York City.

    Science.gov (United States)

    Crawford, Natalie D; Amesty, Silvia; Rivera, Alexis V; Harripersaud, Katherine; Turner, Alezandria; Fuller, Crystal M

    2013-09-01

    Structural interventions may help reduce racial/ethnic disparities in HIV. In 2009 to 2011, we randomized pharmacies participating in a nonprescription syringe access program in minority communities to intervention (pharmacy enrolled and delivered HIV risk reduction information to injection drug users [IDUs]), primary control (pharmacy only enrolled IDUs), and secondary control (pharmacy did not engage IDUs). Intervention pharmacy staff reported more support for syringe sales than did control staff. An expanded pharmacy role in HIV risk reduction may be helpful.

  20. Direct conversion of radioactive and chemical waste containing metals, ceramics, amorphous solids, and organics to glass

    International Nuclear Information System (INIS)

    Forsberg, C.W.; Beahm, E.C.; Parker, G.W.

    1994-01-01

    The Glass Material Oxidation and Dissolution System (CMODS) is a new process for direct conversion of radioactive, mixed, and chemical wastes to glass. The wastes can be in the chemical forms of metals, ceramics, amorphous solids, and organics. GMODS destroys organics and it incorporates heavy metals and radionuclides into a glass. Processable wastes may include miscellaneous spent fuels (SF), SF hulls and hardware, plutonium wastes in different forms, high-efficiency particulate air (HEPA) filters, ion-exchange resins, failed equipment, and laboratory wastes. Thermodynamic calculations indicate theoretical feasibility. Small-scale laboratory experiments (< 100 g per test) have demonstrated chemical laboratory feasibility for several metals. Additional work is needed to demonstrate engineering feasibility

  1. An augmented-reality edge enhancement application for Google Glass.

    Science.gov (United States)

    Hwang, Alex D; Peli, Eli

    2014-08-01

    Google Glass provides a platform that can be easily extended to include a vision enhancement tool. We have implemented an augmented vision system on Glass, which overlays enhanced edge information over the wearer's real-world view, to provide contrast-improved central vision to the Glass wearers. The enhanced central vision can be naturally integrated with scanning. Google Glass' camera lens distortions were corrected by using an image warping. Because the camera and virtual display are horizontally separated by 16 mm, and the camera aiming and virtual display projection angle are off by 10°, the warped camera image had to go through a series of three-dimensional transformations to minimize parallax errors before the final projection to the Glass' see-through virtual display. All image processes were implemented to achieve near real-time performance. The impacts of the contrast enhancements were measured for three normal-vision subjects, with and without a diffuser film to simulate vision loss. For all three subjects, significantly improved contrast sensitivity was achieved when the subjects used the edge enhancements with a diffuser film. The performance boost is limited by the Glass camera's performance. The authors assume that this accounts for why performance improvements were observed only with the diffuser filter condition (simulating low vision). Improvements were measured with simulated visual impairments. With the benefit of see-through augmented reality edge enhancement, natural visual scanning process is possible and suggests that the device may provide better visual function in a cosmetically and ergonomically attractive format for patients with macular degeneration.

  2. Groundwater sampling methods using glass wool filtration to trace human enteric viruses in Madison, Wisconsin

    Science.gov (United States)

    Human enteric viruses have been detected in the Madison, Wisconsin deep municipal well system. Earlier projects by the Wisconsin Geological and Natural History Survey (WGNHS) have used glass wool filters to sample groundwater for these viruses directly from the deep municipal wells. Polymerase chain...

  3. Intrathecal catheter-syringe adaptor for short-term intrathecal analgesia with an externalized pump: a case report.

    Science.gov (United States)

    Wilkes, Denise; Cook, Michael; Solanki, Daneshvari

    2010-01-01

    In most patients, cancer pain is effectively treated with conservative medical management consisting of oral and/or transdermal analgesics. Cancer patients tend to fail conservative medical management near the end of their life expectancy, thus requiring alternative routes of analgesia such as intravenous, epidural, or intrathecal. The intrathecal route provides the most effective analgesia due to the close proximity of the opioid receptors in the spinal cord. Though there are many techniques that exist for intrathecal drug delivery, complications can limit effectiveness such as infection, bleeding, cerebrospinal fluid (CSF) leaks, post-dural puncture headaches (PDPH), pump and/or catheter malfunctions, or limitations of technical expertise. Therefore, an important goal in palliative cancer pain therapy is to use equipment that is going to have the fewest number of complications and will be the most familiar to the health care providers. We describe the combination of the Medtronic Indura 1P catheter, which has the least catheter-related complications and can be used with any external drug infusion pump. These are regular infusion pumps that the health care workers are familiar with so they can provide excellent and efficient service to the patient. In an operating room, the intrathecal catheter was placed using sterile technique under fluoroscopic guidance. The epidural space was identified with loss of resistance technique. Then the introducer needle (supplied in the Indura 1P catheter kit) was advanced until free-flowing CSF was obtained. The spinal catheter was advanced into the intrathecal space through the introducer needle to lumbar 2-3 level. The catheter was tunneled subcutaneously 10 cm lateral to the catheter exit site. A syringe filling device was inserted into the catheter opening and was secured with silk suture. A luer lock syringe was attached to the syringe filling device and CSF was aspirated. The syringe filling device was capped and later

  4. Moving beyond non-engagement on regulated needle-syringe exchange programs in Australian prisons

    Directory of Open Access Journals (Sweden)

    Levy Michael

    2009-05-01

    Full Text Available Abstract Background Australia is at a fork in the road with the possibility of a needle-syringe exchange program (NSP to be introduced at the new prison in the ACT. However, the current situation is characterised by non-engagement from major stakeholders. We explore why informed discussion will not be enough to convince prison officers, policy makers and the wider community of the benefits of prison-based NSPs. Other methods of engagement and communication will be proposed – in that may provide avenues for "breakthrough". Methods A review of the literature on needle-syringe exchanges and harm reduction strategies within the context of prisons and prisoner health was conducted. Literature on strategies to change attitudes and move beyond intractable situations was also consulted. In addition, one author, DM, conducted a two-hour interview with an ex-prison officer. Results No studies were found which investigated the potential efficacy of interventions to modify attitudes or behaviours in the specific context of introducing an NSP into a prison. Nonetheless, several theories were identified which may explain the failure of informed discussion alone to create change in this situation and may therefore lead to suggestions for engagement and communication to move towards a resolution Discussion Cognitive-behavioural therapy highlights the importance of individual cognitions and how they shape behaviours in any change campaign. Social identity theory emphasizes changes to social processes that may open the prison officer workforce to change. Peace studies also suggests socialization strategies such as observing an established and effective prison-based needle-syringe exchange. Social marketing provides suggestions on how to sell an exchange to ensuring the benefits are framed to outweigh the costs. Conclusion Psychology, peace studies and social marketing all agree people's views must be carefully collected and analysed if people are going to be

  5. DWPF GLASS BEADS AND GLASS FRIT TRANSPORT DEMONSTRATION

    Energy Technology Data Exchange (ETDEWEB)

    Adamson, D; Bradley Pickenheim, B

    2008-11-24

    DWPF is considering replacing irregularly shaped glass frit with spherical glass beads in the Slurry Mix Evaporator (SME) process to decrease the yield stress of the melter feed (a non-Newtonian Bingham Plastic). Pilot-scale testing was conducted on spherical glass beads and glass frit to determine how well the glass beads would transfer when compared to the glass frit. Process Engineering Development designed and constructed the test apparatus to aid in the understanding and impacts that spherical glass beads may have on the existing DWPF Frit Transfer System. Testing was conducted to determine if the lines would plug with the glass beads and the glass frit slurry and what is required to unplug the lines. The flow loop consisted of vertical and horizontal runs of clear PVC piping, similar in geometry to the existing system. Two different batches of glass slurry were tested: a batch of 50 wt% spherical glass beads and a batch of 50 wt% glass frit in process water. No chemicals such as formic acid was used in slurry, only water and glass formers. The glass beads used for this testing were commercially available borosilicate glass of mesh size -100+200. The glass frit was Frit 418 obtained from DWPF and is nominally -45+200 mesh. The spherical glass beads did not have a negative impact on the frit transfer system. The transferring of the spherical glass beads was much easier than the glass frit. It was difficult to create a plug with glass bead slurry in the pilot transfer system. When a small plug occurred from setting overnight with the spherical glass beads, the plug was easy to displace using only the pump. In the case of creating a man made plug in a vertical line, by filling the line with spherical glass beads and allowing the slurry to settle for days, the plug was easy to remove by using flush water. The glass frit proved to be much more difficult to transfer when compared to the spherical glass beads. The glass frit impacted the transfer system to the point

  6. DWPF GLASS BEADS AND GLASS FRIT TRANSPORT DEMONSTRATION

    International Nuclear Information System (INIS)

    Adamson, D.; Pickenheim, Bradley

    2008-01-01

    DWPF is considering replacing irregularly shaped glass frit with spherical glass beads in the Slurry Mix Evaporator (SME) process to decrease the yield stress of the melter feed (a non-Newtonian Bingham Plastic). Pilot-scale testing was conducted on spherical glass beads and glass frit to determine how well the glass beads would transfer when compared to the glass frit. Process Engineering Development designed and constructed the test apparatus to aid in the understanding and impacts that spherical glass beads may have on the existing DWPF Frit Transfer System. Testing was conducted to determine if the lines would plug with the glass beads and the glass frit slurry and what is required to unplug the lines. The flow loop consisted of vertical and horizontal runs of clear PVC piping, similar in geometry to the existing system. Two different batches of glass slurry were tested: a batch of 50 wt% spherical glass beads and a batch of 50 wt% glass frit in process water. No chemicals such as formic acid was used in slurry, only water and glass formers. The glass beads used for this testing were commercially available borosilicate glass of mesh size -100+200. The glass frit was Frit 418 obtained from DWPF and is nominally -45+200 mesh. The spherical glass beads did not have a negative impact on the frit transfer system. The transferring of the spherical glass beads was much easier than the glass frit. It was difficult to create a plug with glass bead slurry in the pilot transfer system. When a small plug occurred from setting overnight with the spherical glass beads, the plug was easy to displace using only the pump. In the case of creating a man made plug in a vertical line, by filling the line with spherical glass beads and allowing the slurry to settle for days, the plug was easy to remove by using flush water. The glass frit proved to be much more difficult to transfer when compared to the spherical glass beads. The glass frit impacted the transfer system to the point

  7. Effect of different glasses in glass bonded zeolite

    International Nuclear Information System (INIS)

    Lewis, M.A.; Ackerman, J.P.; Verma, S.

    1995-01-01

    A mineral waste form has been developed for chloride waste salt generated during the pyrochemical treatment of spent nuclear fuel. The waste form consists of salt-occluded zeolite powders bound within a glass matrix. The zeolite contains the salt and immobilizes the fission products. The zeolite powders are hot pressed to form a mechanically stable, durable glass bonded zeolite. Further development of glass bonded zeolite as a waste form requires an understanding of the interaction between the glass and the zeolite. Properties of the glass that enhance binding and durability of the glass bonded zeolite need to be identified. Three types of glass, boroaluminosilicate, soda-lime silicate, and high silica glasses, have a range of properties and are now being investigated. Each glass was hot pressed by itself and with an equal amount of zeolite. MCC-1 leach tests were run on both. Soda-lime silicate and high silica glasses did not give a durable glass bonded zeolite. Boroaluminosilicate glasses rich in alkaline earths did bind the zeolite and gave a durable glass bonded zeolite. Scanning electron micrographs suggest that the boroaluminosilicate glasses wetted the zeolite powders better than the other glasses. Development of the glass bonded zeolite as a waste form for chloride waste salt is continuing

  8. Emission characteristics of plastic syringes sterilized with ethylene oxide--a controlled study.

    Science.gov (United States)

    Chien, Yeh-Chung; Su, Po-Chi; Lee, Lien-Hsiung; Chen, Chang-Yuh

    2009-11-01

    This study examined the emission characteristics of ethylene oxide (EO)-sterilized syringes under various environmental conditions, aiming to develop control strategies to minimize worker exposure. Experiments were performed in a facility in which temperature, relative humidity (RH), and air change rate (ACR) were controlled. Analytical results indicate that the main effects of the four test variables on kinetic parameters were statistically significant (p Plastic content, temperature, RH, and ACR affected EO emissions. ACR is an achievable means of control; however, the aeration area/system should be isolated to ensure adequate ventilation is achieved.

  9. Syringe-Injectable Electronics with a Plug-and-Play Input/Output Interface.

    Science.gov (United States)

    Schuhmann, Thomas G; Yao, Jun; Hong, Guosong; Fu, Tian-Ming; Lieber, Charles M

    2017-09-13

    Syringe-injectable mesh electronics represent a new paradigm for brain science and neural prosthetics by virtue of the stable seamless integration of the electronics with neural tissues, a consequence of the macroporous mesh electronics structure with all size features similar to or less than individual neurons and tissue-like flexibility. These same properties, however, make input/output (I/O) connection to measurement electronics challenging, and work to-date has required methods that could be difficult to implement by the life sciences community. Here we present a new syringe-injectable mesh electronics design with plug-and-play I/O interfacing that is rapid, scalable, and user-friendly to nonexperts. The basic design tapers the ultraflexible mesh electronics to a narrow stem that routes all of the device/electrode interconnects to I/O pads that are inserted into a standard zero insertion force (ZIF) connector. Studies show that the entire plug-and-play mesh electronics can be delivered through capillary needles with precise targeting using microliter-scale injection volumes similar to the standard mesh electronics design. Electrical characterization of mesh electronics containing platinum (Pt) electrodes and silicon (Si) nanowire field-effect transistors (NW-FETs) demonstrates the ability to interface arbitrary devices with a contact resistance of only 3 Ω. Finally, in vivo injection into mice required only minutes for I/O connection and yielded expected local field potential (LFP) recordings from a compact head-stage compatible with chronic studies. Our results substantially lower barriers for use by new investigators and open the door for increasingly sophisticated and multifunctional mesh electronics designs for both basic and translational studies.

  10. Wideband filter radiometers for blackbody temperature measurements

    Science.gov (United States)

    Boivin, L. P.; Bamber, C.; Gaertner, A. A.; Gerson, R. K.; Woods, D. J.; Woolliams, E. R.

    2010-10-01

    The use of high-temperature blackbody (HTBB) radiators to realize primary spectral irradiance scales requires that the operating temperature of the HTBB be accurately determined. We have developed five filter radiometers (FRs) to measure the temperature of the National Research Council of Canada's HTBB. The FRs are designed to minimize sensitivity to ambient temperature fluctuations. They incorporate air-spaced colored glass filters and a Si photodiode detector that are housed in a cell whose temperature is controlled to ±0.1°C by means of annular thermoelectric elements at the front and rear of the cell. These wideband filter radiometers operate in four different wavelength bands. The spectral responsivity measurements were performed in an underfill geometry for a power-mode calibration that is traceable to NRC's cryogenic radiometer. The spectral temperature sensitivity of each of these FRs has been measured. The apertures for these FRs were cold-formed by swaging machine-cut apertures onto precision dowel pins. A description of the filter radiometer design, fabrication and testing, together with a detailed uncertainty analysis, is presented. We derive the equations that relate the spectral irradiance measured by the FRs to the spectral radiance and temperature of the HTBB, and deal specifically with the change of index of refraction over the path of the radiation from the interior of the HTBB to the FRs. We believe these equations are more accurate than recently published derivations. Our measurements of the operating temperature of our HTBB working at temperatures near 2500 K, 2700 K and 2900 K, together with measurements using a pyrometer, show agreement between the five filter radiometers and with the pyrometer to within the estimated uncertainties.

  11. The development of a HEPA filter with improved dust holding characteristics

    International Nuclear Information System (INIS)

    Dyment, J.; Hamblin, C.

    1995-01-01

    A limitation of the HEPA filters used in the extract of nuclear facilities is their relatively low capacity for captured dust. The costs associated with the disposal of a typical filter means that there are clear incentives to extend filter life. The work described in this report are the initial stages in the development of a filter which incorporates a medium which enhances its dust holding capacity. Experimental equipment was installed to enable the dust loading characteristics of candidate media to be compared with those of the glass fibre based papers currently used in filter construction. These tests involved challenging representative samples of the media with an air stream containing a controlled concentration of thermally generated sodium chloride particles. The dust loading characteristics of the media were then compared in terms of the rate of increasing in pressure differential. A number of open-quotes graded densityclose quotes papers were subsequently identified which appeared to offer significant improvements in dust holding. In the second phase of the programme deep-pleat filters (1,700 M 3 h -1 ) incorporating graded density papers were manufactured and tested. Improvements of up to 50% were observed in their capacity for the sub-micron sodium chloride test dust. Smaller differences (15%) were measured when a coarser, carbon black, challenge was used. This is attributed to the differences in the particles sizes of the two dusts

  12. Glass bottle sampling solid phase microextraction gas chromatography mass spectrometry for breath analysis of drug metabolites.

    Science.gov (United States)

    Lu, Yan; Niu, Wenqi; Zou, Xue; Shen, Chengyin; Xia, Lei; Huang, Chaoqun; Wang, Hongzhi; Jiang, Haihe; Chu, Yannan

    2017-05-05

    Breath analysis is a non-invasive approach which may be applied to disease diagnosis and pharmacokinetic study. In the case of offline analysis, the exhaled gas needs to be collected and the sampling bag is often used as the storage vessel. However, the sampling bag usually releases some extra compounds, which may interfere with the result of the breath test. In this study, a novel breath sampling glass bottle was developed with a syringe needle sampling port for solid phase microextraction (SPME). Such a glass bottle scarcely liberates compounds and can be used to collect exhaled gas for ensuing analysis by gas chromatography-mass spectrometry (GC-MS). The glass bottle sampling SPME-GC-MS analysis was carried out to investigate the breath metabolites of myrtol, a multicompound drug normally used in the treatment of bronchitis and sinusitis. Four compounds, α-pinene, 2,3-dehydro-1,8-cineole, d-limonene and 1,8-cineole were found in the exhaled breath of all eight volunteers who had taken the myrtol. While for other ten subjects who had not used the myrtol, these compounds were undetectable. In the SPME-GC-MS analysis of the headspace of myrtol, three compounds were detected including α-pinene, d-limonene and 1,8-cineole. Comparing the results of breath and headspace analysis, it indicates that 2,3-dehydro-1,8-cineole in the breath is the metabolite of 1,8-cineole. It is the first time that this metabolite was identified in human breath. The study demonstrates that the glass bottle sampling SPME-GC-MS method is applicable to exhaled gas analysis including breath metabolites investigation of drugs like myrtol. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. From medicine to natural philosophy: Francis Hauksbee's way to the air-pump.

    Science.gov (United States)

    Brundtland, Terje

    2008-06-01

    Francis Hauksbee (1660-1713) is well known for his double-barrelled air-pump. However, the origin of this pump, and Hauksbee's background, are often described as a mystery. This text seeks to dispel the riddle. It is argued that Hauksbee's competence as an exceptional maker of air-pumps was developed between 1699 and 1703 as a result of his experiences with the construction, manufacturing and sale of cupping-glasses. His cupping utensils embodied a new design, where syringes were used to evacuate the glasses, instead of the traditional way by fire or mouth suction. These syringes, which in fact were small air-pumps, were perfected between 1699 and 1701. A larger syringe, introduced in 1701, served as a transition from the cupping-syringe to his first air-pump for use in natural philosophy. This syringe was described as a 'combined engine', which could serve as an air-pump, a condensing engine and a syringe for injecting air, wax or mercury into pathological specimens. Hauksbee's first air-pump was a single-barrelled model introduced in 1702, based on the combined engine. Its various features, such as easy and convenient leak-tightening, exact pressure measurements by an in-built barometer and an air-inlet function for readmission of air into the receiver, are discussed. Finally, it is shown that these activities gave Hauksbee the reputation of being an outstanding instrument-maker, years before the double-barrelled air-pump was in sight.

  14. Cultivation and Differentiation of Encapsulated hMSC-TERT in a Disposable Small-Scale Syringe-Like Fixed Bed Reactor

    DEFF Research Database (Denmark)

    Weber, Christian; Pohl, Sebastian; Pörtner, Ralf

    2007-01-01

    The use of commercially available plastic syringes is introduced as disposable small-scale fixed bed bioreactors for the cultivation of implantable therapeutic cell systems on the basis of an alginate-encapsulated human mesenchymal stem cell line. The system introduced is fitted with a noninvasiv...

  15. SQUID measurements of remanent magnetisation in refillable 3He spin-filter cells (SFC)

    Science.gov (United States)

    Hutanu, V.; Rupp, A.; Sander-Thömmes, T.

    2007-07-01

    A strong influence of external magnetic fields on the relaxation time constant T1 of glass cells serving as reservoirs for polarised 3He, observed for various alkali metal-coated cells made of different glass types, was initially associated with the presence of a large number of ferromagnetic clusters on the glass surface. Later experiments showed the presence of the so-called “ T1 hysteresis” phenomenon with a similar distinctiveness also in uncoated cells made of pure synthetic quartz glass. It suggests that the origin of such a relaxation is a macroscopic magnetisation in the bulk of the cell. We present the results of a multi-SQUID system investigation on magnetised and non-magnetised quartz glass cells, Cs coated as well as bare wall, to be used as neutron spin filters at HMI Berlin. The presence of a macroscopic remanent magnetic moment in the cells after their exposition to external magnetic fields has been experimentally shown. More than 80% of the remanent magnetic moment of the magnetised cells was found to be concentrated in the region of the glass valves. SQUID measurements reveal the existence of some remanent magnetisation in all valve parts and also in the vacuum grease, but most magnetic are the plastic parts and the O-ring. Different valve and sealing types have been compared in order to find the less magnetisable one.

  16. Development and evaluation of a HEPA filter for increased strength and resistance to elevated temperature

    International Nuclear Information System (INIS)

    Gilbert, H.; Bergman, W.; Fretthold, J.K.

    1993-01-01

    We have completed a preliminary study of an improved HEPA filter for increased strength and resistance to elevated temperature to improve the reliability of the standard deep pleated HEPA filter under accident conditions. The improvements to the HEPA filter consist of a silicone rubber sealant and a new HEPA medium reinforced with a glass cloth. Three prototype filters were built and evaluated for temperature and pressure resistance and resistance to rough handling. The temperature resistance test consisted of exposing the HEPA filter to 1,000 scan (1,700 m 3 /hr) at 700 degrees F (371 degrees C) for five minutes.The pressure resistance test consisted of exposing the HEPA filter to a differential pressure of 10 in. w.g. (2.5 kPa) using a water saturated air flow at 95 degrees F (35 degrees C). For the rough handling test, we used a vibrating machine designated the Q110. DOP filter efficiency tests were performed before and after each of the environmental tests. In addition to following the standard practice of using a separate new filter for each environmental test, we also subjected the same filter to the elevated temperature test followed by the pressure resistance test. The efficiency test results show that the improved HEPA filter is significantly better than the standard HEPA filter. Further studies are recommended to evaluate the improved HEPA filter and to assess its performance under more severe accident conditions

  17. Characterization of glass and glass ceramic nuclear waste forms

    International Nuclear Information System (INIS)

    Lutze, W.; Borchardt, J.; De, A.K.

    1979-01-01

    Characteristics of solidified nuclear waste forms, glass and glass ceramic compositions and the properties (composition, thermal stability, crystallization, phase behavior, chemical stability, mechanical stability, and radiation effects) of glasses and glass ceramics are discussed. The preparation of glass ceramics may be an optional step for proposed vitrification plants if tailored glasses are used. Glass ceramics exhibit some improved properties with respect to glasses. The overall leach resistance is similar to that of glasses. An increased leach resistance may become effective for single radionuclides being hosted in highly insoluble crystal phases mainly when higher melting temperatures are applicable in order to get more leach resistant residual glass phases. The development of glass ceramic is going on. The technological feasibility is still to be demonstrated. The potential gain of stability when using glass ceramics qualifies the material as an alternative nuclear waste form

  18. Glass-ceramics with multibarrier structure obtained from industrial waste

    Energy Technology Data Exchange (ETDEWEB)

    Berzina, L.; Cimdins, R.; Rozenstrauha, I. [Riga Tech. Univ. (Latvia). Fac. of Chem. Technol.; Bossert, J. [Technisches Inst.: Materialwissenschaft, Friedrich-Schiller-Univ., Jena (Germany); Kravtchenko, I. [Inst. for Problems of Material Science, Kiev (Ukraine)

    1997-12-31

    Recycling problem for various kind of waste is solved by processing the waste to ecological depositable products with multibarrier structure. In order to form a multibarrier structure the ecologically incompatible substances may be diluted and chemically bound until their recycling products gain a structure like natural mineral or glass (I. barrier). After that, remineralized materials are converted into a new product by melting or powder technology using an ecological compatible type of waste as a matrix phase (II. barrier). Waste which are treated this way could be applied to produce ceramic building materials and goods such as floor tiles, stone pavement and casting products. Industrial waste from the metallurgical factory in Latvia ``Liepajas metalurgs`` are metallurgical slag, filter dust, etching waste and sewage used in technologies. The main constituents of chemical compositions of these waste are: Fe, Ca, Si, Mg, Al, Mn etc. In some types of waste a small amount of ecologically risky elements such as Cr, Ni, Zr, Sn and Pb can occur. The combination of metallurgical waste with peat ashes from Riga thermal power station, oil shale ashes or glass waste under controlled sintering procedure gives bulk materials with surface or/and bulkcrystallization. The structure of glass-ceramics built this way may prevent the migration of ecologically risky elements into environment due to corrosion or friction. Physical-chemical properties and thermal behaviour (DTA, dilatometry, melting) of waste define the range of sintering for production of glass-ceramics (powder technology) and decorative glass-ceramic materials (melting and powder technology). (orig.) 5 refs.

  19. Vertical removable filters in shielded casing for radioactive cells and process gaseous wastes

    International Nuclear Information System (INIS)

    Prinz, M.

    1983-01-01

    The installation of shielded filtration casing is necessary for highly contaminated active cells and process gaseous wastes containing active aerosols. SGN and COGEMA have developed two filtration casings (for 500 and 3000 m 3 /h flow rates) equipped with a vertically removable filter element. The filter elements fitted with high efficiency glass fiber media, are cylindrical in shape. The top flange of the filter is equipped with a gasket to ensure sealing between the filter element and its casing. The filter element is blindly installed and removed and its orientation, inside the casing, is immaterial. The shielding casing is made of a cast iron, or steel, shielding slab under which is secured the filtration casing itself. This shielding slab is settled on side shielding walls made of concrete or cast iron. The filter element, integral with a plug, is placed in the horizontal slab. The attachment of the filter element under the plug is necessary so that the plug and filter may be removed as one unit, and to keep the filter on its sealing surfaces, according to sealing and seismic resistance requirements. Filter removal is performed with the help of an intervention cask, centered over a removable trap door provided on the shielding slab of the casing. First, the plug and filter element assembly is raised into the cask. Then, the filtering element may be separated from the plug which is decontaminated and salvaged. The whole plug and filter assembly may also be sent to the conditioning waste storage. The installation of a clean filter element in the casing, is also performed with the help of the intervention cask, proceeding as above, but in reverse order. The same intervention cask may also be used to remove the upstream and downstream dampers from the top of the casing

  20. Syringe test screening of microbial gas production activity: Cases denitrification and biogas formation.

    Science.gov (United States)

    Østgaard, Kjetill; Kowarz, Viktoria; Shuai, Wang; Henry, Ingrid A; Sposob, Michal; Haugen, Hildegunn Hegna; Bakke, Rune

    2017-01-01

    Mass produced plastic syringes may be applied as vessels for cheap, simple and large scale batch culture testing. As illustrated for the cases of denitrification and of biogas formation, metabolic activity was monitored by direct reading of the piston movement due to the gas volume formed. Pressure buildup due to friction was shown to be moderate. A piston pull and slide back routine can be applied before recording gas volume to minimize experimental errors due to friction. Inoculum handling and activity may be conveniently standardized as illustrated by applying biofilm carriers. A robust set of positive as well as negative controls ("blanks") should be included to ensure quality of the actual testing. The denitrification test showed saturation response at increasing amounts of inoculum in the form of adapted moving bed biofilm reactor (MBBR) carriers, with well correlated nitrate consumption vs. gas volume formed. As shown, the denitrification test efficiently screened different inocula at standardized substrates. Also, different substrates were successfully screened and compared at standardized inocula. The biogas potential test showed efficient screening of different substrates with effects of relative amounts of carbohydrate, protein, fat. A second case with CO 2 capture reclaimer waste as substrate demonstrated successful use of co-feeding to support waste treatment and how temperature effects on kinetics and stoichiometry can be observed. In total, syringe test screening of microbial gas production seems highly efficient at a low cost when properly applied. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Time-Sequential Working Wavelength-Selective Filter for Flat Autostereoscopic Displays

    Directory of Open Access Journals (Sweden)

    René de la Barré

    2017-02-01

    Full Text Available A time-sequential working, spatially-multiplexed autostereoscopic 3D display design consisting of a fast switchable RGB-color filter array and a fast color display is presented. The newly-introduced 3D display design is usable as a multi-user display, as well as a single-user system. The wavelength-selective filter barrier emits the light from a larger aperture than common autostereoscopic barrier displays with similar barrier pitch and ascent. Measurements on a demonstrator with commercial display components, simulations and computational evaluations have been carried out to describe the proposed wavelength-selective display design in static states and to show the weak spots of display filters in commercial displays. An optical modelling of wavelength-selective barriers has been used for instance to calculate the light ray distribution properties of that arrangement. In the time-sequential implementation, it is important to avoid that quick eye or eyelid movement leads to visible color artifacts. Therefore, color filter cells, switching faster than conventional LC display cells, must distribute directed light from different primaries at the same time, to create a 3D presentation. For that, electric tunable liquid crystal Fabry–Pérot color filters are presented. They switch on-off the colors red, green and blue in the millisecond regime. Their active areas consist of a sub-micrometer-thick nematic layer sandwiched between dielectric mirrors and indium tin oxide (ITO-electrodes. These cells shall switch narrowband light of red, green or blue. A barrier filter array for a high resolution, glasses-free 3D display has to be equipped with several thousand switchable filter elements having different color apertures.

  2. Evaluation of Dark Spots Formated on the High Temperature Metal Filter Elements

    International Nuclear Information System (INIS)

    Park, Seung Chul; Hwang, Tae Won; Moon, Chan Kook

    2008-01-01

    Metal filter elements were newly introduced to the high temperature filter (HTF) system in the low- and intermediate-level radioactive waste vitrification plant. In order to evaluate the performance of various metal materials as filter media, elements made of AISI 316L, AISI 904L, and Inconel 600 were included to the test set of filter elements. At the visual inspection to the elements performed after completion of each test, a few dark spots were observed on the surface of some elements. Especially they were found much more at the AISI 316L elements than others. To check the dark spots are the corrosion phenomena or not, two kinds of analyses were performed to the tested filter elements. Firstly, the surfaces or the cross sections of filter specimens cut out from both normal area and dark spot area of elements were analyzed by SEM/EDS. The results showed that the dark spots were not evidences of corrosion but the deposition of sodium, sulfur and silica compounds volatilized from waste or molten glass. Secondly, the ring tensile strength were analyzed for the ring-shape filter specimens cut out from each kind of element. The result obtained from the strength tested showed no evidence of corrosion as well. Conclusionally, depending on the two kinds of analysis, no evidences of corrosion were found at the tested metal filter elements. But the dark spots formed on the surface could reduce the effective filtering area and increase the overall pressure drop of HTF system. Thus, continuous heating inside filter housing up to dew point will be required normally. And a few long-period test should be followed for the exact evaluation of corrosion of the metal filter elements.

  3. Vanillic and syringic acids from biomass burning: Behaviour during Fenton-like oxidation in atmospheric aqueous phase and in the absence of light

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Gabriela T.A.D.; Santos, Patrícia S.M., E-mail: patricia.santos@ua.pt; Duarte, Armando C.

    2016-08-05

    Highlights: • The rate of oxidation of small aromatic acids increase with the pH decrease. • With the oxidation of aromatic acids are formed new small aromatic compounds. • The initial and formed compounds are not totally degraded during the night period. • The substituents and their positions in ring affect the oxidation of aromatic acids. • The OH radical attack to vanillic and syringic acids is different in atmospheric waters. - Abstract: Biomass combustion is a threat to the environment since it emits to the atmosphere organic compounds, which may react and originate others more aggressive. This work studied the behaviours of vanillic and syringic acids, small aromatic tracers of biomass burning, during Fenton-like oxidation in aqueous phase and absence of light. For both compounds, the extent of oxidation increased with pH decrease from neutral to acid in atmospheric waters, but for vanillic acid the neutral pH was not able of promoting the oxidation. With the oxidation of both acids were formed chromophoric compounds, and the formation rate increased with the degree of electron-donator substituents in benzene ring. The initial and produced compounds were not totally degraded up to 24 h of reaction at pH 4.5, suggesting that the night period may be not sufficient for their full degradation in atmospheric waters. The major compounds formed were the 3,4-dihydroxybenzoic acid for vanillic acid, and the 1,4-dihydroxy-2,6-dimethoxybenzene for syringic acid. These findings suggest the occurrence of an ipso attack by the hydroxyl radical preferential to the methoxy and carboxyl groups of vanillic and syringic acids, respectively. It is important to highlight that for both aromatic acids the main compounds produced are also small aromatic compounds.

  4. Viral Penetration of High Efficiency Particulate Air (HEPA) Filters (PREPRINT)

    Science.gov (United States)

    2009-09-01

    US Plastics, Lima , 155 Ohio). Each path runs through a test article and thence through one AGI-30 all-glass 156 impinger (Chemglass, Vineland, N.J...rotameter (Blue–White 400, Huntington Beach , California, or PMR1-159 101346, Cole–Parmer, Vernon Hills, Illinois). At the end of the sampling path...fibrous Filters." J. Air Pollution Control Assoc. 30 [4]: 501 377–381. 502 Leenders, G.J.M, A.C. Bolle, and J. Stadhouders. 1984. “A Study of the

  5. Doses rate in contact with plastic syringes of 1, 2 and 5 mL for different beta and gamma emitting radionuclides

    International Nuclear Information System (INIS)

    Torres Berdeguez, Mirta; Ayra Pardo, Enrique; Falcon, Lazaro

    2008-01-01

    The objective of this paper is to calculate the dose rate in contact with plastic syringes of 1, 2 and 5 m L volume, unshielded and the dose rate in the same syringes after a lead or a Lucite shield of various thickness has been installed, depending on the emission of the radionuclide used. The radionuclides involved in the assessment were 32 P, 51 Cr, 90 Y, 99m Tc, 125 I, 131 I, 153 Sm, 186 Re, 188 Re, 169 Er and 177 Lu. The code used was the MCNP4C. The results are intended to be used by a Radiation Protection Officer wherever the radionuclides in question are handled to rapidly assess the dose in hands of the operators. (author)

  6. Bioenergy and biofertilizer : improvement of biogas production from filter cake

    Energy Technology Data Exchange (ETDEWEB)

    Fonte, A.H. [Environmental Bioremediation Group, Research and Development Agency, GeoCuba, Camaguey (Cuba); Alvarez, R.C. [Provincial Direction of Soils, Camaguey (Cuba)

    2000-07-01

    The anaerobic digestion of sugar mill filter cake (SMFC) was studied using a natural zeolite to intensify the biogas production. The anaerobic digestion (AD) of agricultural waste mixtures in certain proportions is the underlying basis of biogas generation. Earlier studies have shown that certain inert materials can act as stimulators in biogas production when used in conjunction with AD. This study involved three experiments using filter cake from different sugar mills using three doses of zeolite to determine how they stimulate biogas production. Another objective of the study was to determine if the mud of the digester containing the added zeolite has an impact on plants and soil. The study was conducted under glass house conditions using a brown soil with carbonates with neutral pH and high contents of P{sub 2}O{sub 5}, K{sub 2}O and organic matter. It was concluded that it is possible to increase the biogas yield and to improve AD behaviour of the filter cake by using a zeolite adapted to unique operating conditions. The amount of yield depends on the origin of the filter cake, the stimulator dose and age. Results were in the order of 20-40 per cent biogas production. Fresh filter cake was found to produce more biogas. The mud of the anaerobic digestion of the filter cake containing zeolite positively impacted on the agronomic behaviour of the sorghum in relation to P{sub 2}O{sub 5}, K{sub 2}O and organic matter content. 19 refs., 4 tabs.

  7. The development of a HEPA filter with improved dust holding characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Dyment, J.; Hamblin, C.

    1995-02-01

    A limitation of the HEPA filters used in the extract of nuclear facilities is their relatively low capacity for captured dust. The costs associated with the disposal of a typical filter means that there are clear incentives to extend filter life. The work described in this report are the initial stages in the development of a filter which incorporates a medium which enhances its dust holding capacity. Experimental equipment was installed to enable the dust loading characteristics of candidate media to be compared with those of the glass fibre based papers currently used in filter construction. These tests involved challenging representative samples of the media with an air stream containing a controlled concentration of thermally generated sodium chloride particles. The dust loading characteristics of the media were then compared in terms of the rate of increasing in pressure differential. A number of {open_quotes}graded density{close_quotes} papers were subsequently identified which appeared to offer significant improvements in dust holding. In the second phase of the programme deep-pleat filters (1,700 M{sup 3}h{sup {minus}1}) incorporating graded density papers were manufactured and tested. Improvements of up to 50% were observed in their capacity for the sub-micron sodium chloride test dust. Smaller differences (15%) were measured when a coarser, carbon black, challenge was used. This is attributed to the differences in the particles sizes of the two dusts.

  8. Stability of sodium bicarbonate injection 8.4% in syringes over a six-week period in refrigerated temperature.

    Science.gov (United States)

    Seki, Jack T; Wang, Tian Q; Yip, Paul M; Mazzulli, Tony; Minden, Mark D

    2018-04-01

    Background Dysfunctional central venous catheter prohibits the administration of potential life-saving chemotherapy and the delivery of essential supportive care needs to patients. Sodium bicarbonate injection has been shown to impede against fibrin clot formation and prolong prothrombin time and thrombin clotting time. Sodium bicarbonate injection has been tried as a second-line agent with good results in a small number of patients (internal data not published) when alteplase failed. We assessed whether the pre-filled sodium bicarbonate injection in 5 mL syringes would not only preserve sterility and retain its pH and concentration but also amount to the potential cost savings for future use when stored in a refrigerated environment. Methodology Twelve pre-filled 5 mL syringes were prepared aseptically, of which four each were tested for pH, sodium bicarbonate injection concentration and sterility when stored in refrigerated temperature over a six-week period. A standard pH meter, enzymatic carbon dioxide analyzer, and a 14-day incubation for microbial detection were employed for this study. Results Sodium bicarbonate concentration measured in the form of carbon dioxide ranged from 923 mmol/L or (1846 mosol/L) to 1006 mmol/L or (2012 mosmol/L), and pH ranged from (7.88 to 8.05) were reported over the duration of the study period. The 14-day incubation period resulted in no microbial growth. Conclusion Our study results have indicated that the pH and sodium bicarbonate injection concentration values were stable and within range, comparable to those reported by the manufacturer within the study period. The contents of the subdivided sodium bicarbonate injection 5 mL syringes retained sterility over a 14-day incubation period.

  9. A new solid phase microextraction method using organic ligand in micropipette tip syringe system packed with modified carbon cloth for preconcentration of cadmium in drinking water and blood samples of kidney failure patients

    Science.gov (United States)

    Panhwar, Abdul Haleem; Kazi, Tasneem Gul; Afridi, Hassan Imran; Arain, Salma Aslam; Naeemullah; Brahman, Kapil Dev; Arain, Mariam Shahzadi

    2015-03-01

    A simple and efficient miniaturized solid phase microextraction (M-SPμE) in a syringe system was developed for preconcentration of cadmium (Cd) in environmental and biological samples, followed by flame atomic absorption technique. The syringe system contains the micropipette tip packed with activated carbon cloth, coated with modified magnetic nanoparticles of iron oxide Triton X114 (ACC-NPs). Scanning electron microscopy and energy dispersive spectroscopy used for characterization of the size, morphology and elemental composition of ACC-NPs. The sample solution treated with a complexing reagent 8-hydroxyqunilone (8-HQ), and drawn into the syringe, filled with ACC-MNPs and dispensed manually for 2-10 drawing/discharging cycles. The analyte retained on ACC-NPs in micropipette tip-syringe system were then eluted with different volume of 1.5 mol L-1 HCl by 1-5 drawing/discharging cycles. The syringe system directly couple with FAAS for analysis. The influence of different variables on the extraction efficiency of Cd, including adsorbent dosage, pH, sample volume, eluent volume and drawing/discharging cycles of syringe system were optimized. At optimized extraction conditions, the method showed good linearity in the range of 5-250 μg L-1, with a limit of detection 0.15 μg L-1. Repeatability of the extraction (%RSD) was <5%, n = 5. The validity and accuracy of the method was checked by the certified reference materials. The proposed method was successfully applied for the determination of Cd in different drinking water and biological samples of kidney failure patients and healthy controls.

  10. A practical guide for nurses in diluent selection for subcutaneous infusion using a syringe driver.

    Science.gov (United States)

    McLeod, Fiona; Flowers, Charne

    2006-12-01

    Appropriate diluent selection in continuous subcutaneous infusion optimises symptom management and client well-being. The responsibility of diluent selection is commonly one of the attending nurse. This paper was developed with the intention of providing nurses with practical instruction for diluent selection when preparing medications for administration subcutaneously using a syringe driver. A literature review was undertaken of published journal databases and published guidelines sites. Recommendations regarding diluent choice were reviewed in two iterations by an expert panel of palliative care nurse clinicians. The principles for diluent selection are presented. They are based primarily on expert opinion level of evidence given a lack of primary research evidence in the area of diluent selection. There is a pressing need for manufacturers' guidance on diluent selection and independent research to establish the impact of diluents on drug and drug combinations when using syringe drivers. Until such time that this evidence is available to guide practice, clinicians need to be trained to inspect solutions and assess the effectiveness of the medication in controlling symptoms. The capacity of this paper to provide practical instruction has been limited by the lack of rigorous evidence available, and indeed, the process of developing this guide identified perhaps more questions than answers available at the present time.

  11. Noise Filter Studies for CMS Forward Hadron Calorimeter (HF) Between Old and New PMT's Using Data in 2012

    CERN Document Server

    Dumanoglu, Isa; Gurpinar, Emine; Kunori, Shuichi; Lezki, Samet; Tali, Bayram

    2016-01-01

    During the data taking before 2012 some abnormal events which have higher signals than expected were observed. Most of these were due to muons. When a muon hits the PMT glass window it creates a huge signal. To eliminate this kind of events 24 old HF PMTs (Hamamatsu R7525) in HF Minus at iphi 43 (corresponds to one sector) were replaced with new multi anode PMTs (Hamamatsu multi anode R7600) which have thin glass windows. These new PMTs were installed and tested in H2 test beam area in 2009 [1]. To check whether these new PMTs perform better than the old ones data taken in 2012 were analyzed using various predefined noise filters. Noisy rechits percentage was found to be around 6-7 \\% for the new PMTs while it varies between 29-66 \\% for the old PMTs for various trigger selections and for HFLongShortFilter after an energy cut of 500GeV [2].

  12. Electrochromic Glasses.

    Science.gov (United States)

    1980-07-31

    this glass and that dipole-dipole correlations contribute to the "ferroelectric-like" character of this amorphous system. The TeO2 -W03 glasses can only...shows the dielectric constant and Fig. I(b) glass from pure TeO2 ot pure WO. In addition, glass the tan 8 of the WO glass as a function of temperature... glasses containing WO, in various glass forming nitworks of LifO-B1O0, Na:O-BzO,, and TeO2 were prepared from reagent grade oxides at 800 C - 9SO C in

  13. 21 CFR 172.864 - Synthetic fatty alcohols.

    Science.gov (United States)

    2010-04-01

    ... syringe. 1-milliliter capacity, with 3-inch, 22-gauge needle. Volumetric flask. 5-milliliter capacity.... Pipet 100 milliliters of 1,2-dichloroethane into a 1-liter glass-stoppered volumetric flask and adjust... into a 1-liter glass-stoppered volumetric flask and adjust to volume with hexane, with mixing. n...

  14. Flexible photonic-crystal Fano filters based on transferred semiconductor nanomembranes

    Energy Technology Data Exchange (ETDEWEB)

    Zhou Weidong; Yang Hongjun; Qiang Zexuan; Chen Li; Yang Weiquan; Chuwongin, Santhad; Zhao Deyin [Department of Electrical Engineering, NanoFAB Center, University of Texas at Arlington, TX 76019 (United States); Ma Zhenqiang; Qin Guoxuan; Pang Huiqing, E-mail: wzhou@uta.ed, E-mail: mazq@engr.wisc.ed [Department of Electrical and Computer Engineering, University of Wisconsin-Madison, WI 53706 (United States)

    2009-12-07

    Crystalline semiconductor nanomembranes (NMs), which are transferable, stackable, bondable and manufacturable, offer unprecedented opportunities for unique and novel device applications. We report and review here nanophotonic devices based on stacked semiconductor NMs that were built on Si, glass and flexible PET substrates. Photonic-crystal Fano resonance based surface-normal optical filters and broadband reflectors have been demonstrated with unique angle and polarization properties. Such a low temperature NM stacking process can lead to a paradigm shift on silicon photonic integration and inorganic flexible photonics.

  15. High-Damage-Threshold Pinhole for Glass Fusion Laser Applications

    International Nuclear Information System (INIS)

    Kumit, N.A.; Letzring, S.A.; Johnson, R.P.

    1998-01-01

    We are investigating methods to fabricate high-damage-threshold spatial-filter pinholes that might not be susceptible to plasma closure for relatively high energies and long pulses. These are based on the observation that grazing-incidence reflection from glass can withstand in excess of 5 kJ/cm 2 (normal to the beam) without plasma formation. The high damage threshold results from both the cos q spreading of the energy across the surface and the reflection of a large fraction of the energy from the surface, thereby greatly reducing the field strength within the medium

  16. Modeling the dissolution behavior of defense waste glass in a salt repository environment

    International Nuclear Information System (INIS)

    McGrain, B.P.

    1988-02-01

    A mechanistic model describing a dynamic mass balance between the production and consumption of dissolved silica was found to describe the dissolution behavior of SRL-165 defense waste glass in a high-magnesium brine (PBB3) at a temperature of 90 0 C. The synergistic effect of the waste package container on the glass dissolution rate was found to depend on a precipitation reaction for a ferrous silicate mineral. The model predicted that the ferrous silicate precipitate should be variable in composition where the iron/silica stoichiometry depended on the metal/glass surface area ratio used in the experiment. This prediction was confirmed experimentally by the variable iron/silica ratios observed in filtered leachates. However, the interaction between dissolved silica and iron corrosion products needs to be much better understood before the model can be used with confidence in predicting radionuclide release rates for a salt repository. 25 refs., 4 figs., 1 tab

  17. Study on the radiation effect of plastic syringe materials

    International Nuclear Information System (INIS)

    Byun, H.C.; Yun, B.M.; Kim, K.Y.; Kong, Y.K.; Park, H.Y.

    1983-01-01

    From the viewpoint of gammasterilization, the defects of domestic polypropylene as the syringe material are to get worse the mechanical properties and discoloration by irradiation. Therefore, the domestic polystyrene (GPPS 150) were inspected to use as substitute for the polypropylene. The gel point of the polystyrene was about 100Mrad and none momentous change of the mechanical properties were appeared until the dose reached to the point. Above the point, as the crosslinking reaction proceed both strength of tensile and impact were increased with discoloration. No significant problem was also found in the water extract test and chemical resistance test. In addition to the pure polystyrene, the copolymer of butadiene (HIPS 425) and the blend material of polypropylene were also inspected for the purpose and almost same results were obtained in the radiation irradiation. From the above result, it is considered that polystyrene and the copolymer and the blend mentioned above are available for the medical plastics which would be sterilized by gamma-radiation. (Author)

  18. Detection algorithm for glass bottle mouth defect by continuous wavelet transform based on machine vision

    Science.gov (United States)

    Qian, Jinfang; Zhang, Changjiang

    2014-11-01

    An efficient algorithm based on continuous wavelet transform combining with pre-knowledge, which can be used to detect the defect of glass bottle mouth, is proposed. Firstly, under the condition of ball integral light source, a perfect glass bottle mouth image is obtained by Japanese Computar camera through the interface of IEEE-1394b. A single threshold method based on gray level histogram is used to obtain the binary image of the glass bottle mouth. In order to efficiently suppress noise, moving average filter is employed to smooth the histogram of original glass bottle mouth image. And then continuous wavelet transform is done to accurately determine the segmentation threshold. Mathematical morphology operations are used to get normal binary bottle mouth mask. A glass bottle to be detected is moving to the detection zone by conveyor belt. Both bottle mouth image and binary image are obtained by above method. The binary image is multiplied with normal bottle mask and a region of interest is got. Four parameters (number of connected regions, coordinate of centroid position, diameter of inner cycle, and area of annular region) can be computed based on the region of interest. Glass bottle mouth detection rules are designed by above four parameters so as to accurately detect and identify the defect conditions of glass bottle. Finally, the glass bottles of Coca-Cola Company are used to verify the proposed algorithm. The experimental results show that the proposed algorithm can accurately detect the defect conditions of the glass bottles and have 98% detecting accuracy.

  19. Relaxations in spin glasses: Similarities and differences from ordinary glasses

    International Nuclear Information System (INIS)

    Ngai, K.L.; Rajagopal, A.K.; Huang, C.Y.

    1984-01-01

    Relaxation phenomena have become a major concern in the physics of spin glasses. There are certain resemblances of these relaxation properties to those of ordinary glasses. In this work, we compare the relaxation properties of spin glasses near the freezing temperature with those of glasses near the glass transition temperature. There are similarities between the two types of glasses. Moreover, the relaxation properties of many glasses and spin glasses are in conformity with two coupled ''universality'' relations predicted by a recent model of relaxations in condensed matter

  20. Results from Evaluation of Proposed ASME AG-1 Section FI Metal Media Filters - 13063

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, John A.; Giffin, Paxton K.; Parsons, Michael S.; Waggoner, Charles A. [Institute for Clean Energy Technology, Mississippi State University, 205 Research Blvd Starkville, MS 39759 (United States)

    2013-07-01

    High efficiency particulate air (HEPA) filtration technology is commonly used in Department of Energy (DOE) facilities that require control of radioactive particulate matter (PM) emissions due to treatment or management of radioactive materials. Although HEPA technology typically makes use of glass fiber media, metal and ceramic media filters are also capable of filtering efficiencies beyond the required 99.97%. Sintered metal fiber filters are good candidates for use in DOE facilities due to their resistance to corrosive environments and resilience at high temperature and elevated levels of relative humidity. Their strength can protect them from high differential pressure or pressure spikes and allow for back pulse cleaning, extending filter lifetime. Use of these filters has the potential to reduce the cost of filtration in DOE facilities due to life cycle cost savings. ASME AG-1 section FI has not been approved due to a lack of protocols and performance criteria for qualifying section FI filters. The Institute for Clean Energy Technology (ICET) with the aid of the FI project team has developed a Section FI test stand and test plan capable of assisting in the qualification ASME AG-1 section FI filters. Testing done at ICET using the FI test stand evaluates resistance to rated air flow, test aerosol penetration and resistance to heated air of the section FI filters. Data collected during this testing consists of temperature, relative humidity, differential pressure, flow rate, upstream particle concentration, and downstream particle concentration. (authors)

  1. Reações locais e níveis de antitoxina circulante decorrentes de administração do toxóide tetânico: estudo comparativo entre Ped-o-Jet e seringa hipodérmica Local reactions and antitoxin levels induced by the administration of tetanus toxoid: a comparative study between Ped-o-Jet and hypodermic syringe

    Directory of Open Access Journals (Sweden)

    Ana Maria Aratangy Pluciennik

    1985-06-01

    the non-black had some kind of local reaction when vaccinated by Ped-o-Jet and 17% when the vaccine was administered by syringe. Systemic reactions did not differ in either group. There was no statistical difference between blacks and non-blacks regarding local reactions. Antibody response to vaccination as measured by the paper filter Whatman # 31 technique, after digital punction, occured in a higher frequency in non-immune individuals vaccinated by Ped-o-Jet than in those vaccinated by hypodermic syringe. While in the first ones only 6.6% did not show serumconvertion, 26.9% of those vaccinated by syringe remained susceptible. The jet injector did not have any performance problems and was well accepted by the subjects, Results led to the conclusion that the Ped-o-Jet can be used for mass vaccination against tetanus.

  2. A computer-controlled syringe driver for use during anaesthesia. A modification of the Graseby MS16A.

    Science.gov (United States)

    Cohen, A T

    1986-06-01

    The requirements of a drug infusion device for use in theatre are discussed. A modification of the Graseby MS16A syringe pump and an interface circuit permitting its remote control by microcomputer are described. The pump is controlled via a standard computer interface (RS232) which makes it a unique and powerful research tool. Aspects of safety are considered.

  3. Glass science tutorial: Lecture No. 7, Waste glass technology for Hanford

    International Nuclear Information System (INIS)

    Kruger, A.A.

    1995-07-01

    This paper presents the details of the waste glass tutorial session that was held to promote knowledge of waste glass technology and how this can be used at the Hanford Reservation. Topics discussed include: glass properties; statistical approach to glass development; processing properties of nuclear waste glass; glass composition and the effects of composition on durability; model comparisons of free energy of hydration; LLW glass structure; glass crystallization; amorphous phase separation; corrosion of refractories and electrodes in waste glass melters; and glass formulation for maximum waste loading

  4. Requirements for a cleanable steel HEPA filter derived from a systems analysis

    International Nuclear Information System (INIS)

    Bergman, W.

    1996-06-01

    A systems analysis was conducted to determine customer requirements for a cleanable high efficiency particulate air (HEPA) filter in DOE Environmental Management (EM) facilities. The three principal drivers for cleanable steel HEPA are large cost savings, improved filter reliability, and new regulations; they produce a strong incentive to DOE customers to use cleanable steel HEPA filters. Input for customer requirements were obtained from field trips to EM sites and from discussions. Most existing applications require that cleanable steel HEPA filters meet size/performance requirements of standard glass HEPA filters; applications in new facilities can relax size/weight/pressure drop requirements on a case-by-case basis. We then obtained input from commercial firms on availability of cleanable steel HEPA filters. Systems analysis then showed that currently available technology was only able to meet customer needs in a limited number of cases. Further development is needed to meet requirements of EM customers. For cleanable steel HEPA to be retrofitted into existing systems, pressure drop and weight must be reduced. Pressure drop can be reduced by developing steel fiber media from 0.5 μm dia steel fibers. Weight can be reduced by packaging the steel fiber media in one of the standard HEPA configurations. Although most applications will be able to use standard 304 or 316L alloys, an acid resistant alloy such as Hastelloy or Inconel will be needed for incinerator and other thermal processes

  5. Analysis of leukocyte binding to depletion filters: role of passive binding, interaction with platelets, and plasma components.

    Science.gov (United States)

    Henschler, R; Rüster, B; Steimle, A; Hansmann, H L; Walker, W; Montag, T; Seifried, E

    2005-08-01

    Since limited knowledge exists on the mechanisms which regulate cell binding to leukocyte removal filter surfaces, we investigated the binding patterns of leukocytes to individual layers of leukocyte depletion filters. After passage of 1 unit of whole blood, blotting of isolated filter layers on glass slides or elution of cells from filter layers revealed that most leukocytes were located within the first 10 of a total of 28 filter layers, peaking at layers 6 to 8, with granulocytes binding on average to earlier filter layers than lymphocytes. Leukocytes preincubated with inhibitors of actin activation showed unchanged distribution between filter layers, suggesting that cytoskeletal activation does not significantly contribute to their binding. When leukocytes were directly incubated with single filter layers, binding of up to 30% of input cells was recorded in the absence of Ca(2+). Immunohistological analyses showed colocalization of platelets and leukocytes, with co-clustering of platelets and leukocytes. Monocytes and to some degree lymphocytes but not granulocytes competed with platelets for filter binding. Precoating of filter layers with individual plasma components showed that hyaluronic acid, plasma type fibronectin, and fibrinogen all increased the binding of leukocytes compared with albumin coating. In conclusion, leukocytes can bind passively to filters in a process which does not require Ca(2+), which is independent of cytoskeletal activation and which may depend on individual plasma components. These results are of importance when new selective cell enrichment or depletion strategies through specific filters are envisaged.

  6. Performance characterization of a pressure-tuned wide-angle Michelson interferometric spectral filter for high spectral resolution lidar

    Science.gov (United States)

    Seaman, Shane T.; Cook, Anthony L.; Scola, Salvatore J.; Hostetler, Chris A.; Miller, Ian; Welch, Wayne

    2015-09-01

    High Spectral Resolution Lidar (HSRL) is typically realized using an absorption filter to separate molecular returns from particulate returns. NASA Langley Research Center (LaRC) has designed and built a Pressure-Tuned Wide-Angle Michelson Interferometer (PTWAMI) as an alternate means to separate the two types of atmospheric returns. While absorption filters only work at certain wavelengths and suffer from low photon efficiency due to light absorption, an interferometric spectral filter can be designed for any wavelength and transmits nearly all incident photons. The interferometers developed at LaRC employ an air spacer in one arm, and a solid glass spacer in the other. Field widening is achieved by specific design and selection of the lengths and refractive indices of these two arms. The principal challenge in using such an interferometer as a spectral filter for HSRL aboard aircraft is that variations in glass temperature and air pressure cause changes in the interferometer's optical path difference. Therefore, a tuning mechanism is needed to actively accommodate for these changes. The pressure-tuning mechanism employed here relies on changing the pressure in an enclosed, air-filled arm of the interferometer to change the arm's optical path length. However, tuning using pressure will not adjust for tilt, mirror warpage, or thermally induced wavefront error, so the structural, thermal, and optical behavior of the device must be well understood and optimized in the design and manufacturing process. The PTWAMI has been characterized for particulate transmission ratio, wavefront error, and tilt, and shows acceptable performance for use in an HSRL instrument.

  7. Mechanical failure and glass transition in metallic glasses

    International Nuclear Information System (INIS)

    Egami, T.

    2011-01-01

    Research highlights: → We review the recent results of molecular dynamics simulations on metallic glasses. → They show the equivalence of mechanical failure and glass transition. → We discuss the microscopic mechanism behind this equivalence. → We show that the density of defects in metallic glasses is as high as a quarter. → Our concepts about the defect state in glasses need to be changed. - Abstract: The current majority view on the phenomenon of mechanical failure in metallic glasses appears to be that it is caused by the activity of some structural defects, such as free-volumes or shear transformation zones, and the concentration of such defects is small, only of the order of 1%. However, the recent results compel us to revise this view. Through molecular dynamics simulation it has been shown that mechanical failure is the stress-induced glass transition. According to our theory the concentration of the liquid-like sites (defects) is well over 20% at the glass transition. We suggest that the defect concentration in metallic glasses is actually very high, and percolation of such defects causes atomic avalanche and mechanical failure. In this article we discuss the glass transition, mechanical failure and viscosity from such a point of view.

  8. Silicate glasses

    International Nuclear Information System (INIS)

    Lutze, W.

    1988-01-01

    Vitrification of liquid high-level radioactive wastes has received the greatest attention, world-wide, compared to any other HLW solidification process. The waste form is a borosilicate-based glass. The production of phosphate-based glass has been abandoned in the western world. Only in the Soviet Union are phosphate-based glasses still being developed. Vitrification techniques, equipment and processes and their remote operation have been developed and studied for almost thirty years and have reached a high degree of technical maturity. Industrial demonstration of the vitrification process has been in progress since 1978. This chapter is a survey of world-wide research and development efforts in nuclear waste glasses and its production technology. The principal glasses considered are silicate glasses which contain boron, i.e., borosilicate glasses

  9. Car glass microphones using piezoelectric transducers for external alarm detection and localization

    Science.gov (United States)

    Bolzmacher, Christian; Le Guelvouit, Valentin

    2015-05-01

    This work describes the potential use of car windows as a long range acoustic sensing device for external alarm signals. The goal is to detect and localize siren signals (e.g. ambulances and police cars) and to alert presbycusic drivers of its presence by visual and acoustic feedback in order to improve individual mobility and increase the sense of security. The glass panes of a Renault Zoé operating as an acoustic antenna have been equipped with large 50 mm outer diameter piezoceramic rings, hidden in the lower part of the door structure and the lower part of the windshield and the rear window. The response of the glass to quasi-static signals and sweep excitation has been recorded. In general, the glass pane is acting as a high pass filter due to its inherent stiffness and provides only little damping. This effect is compensated by using a charge amplifier electronic circuit. The detection capability up to 120 m as well as a dynamic test where the car is moving towards the sound source is reported.

  10. Sensory Pollution from Bag Filters, Carbon Filters and Combinations

    DEFF Research Database (Denmark)

    Bekö, Gabriel; Clausen, Geo; Weschler, Charles J.

    2008-01-01

    by an upstream pre-filter (changed monthly), an EU7 filter protected by an upstream activated carbon (AC) filter, and EU7 filters with an AC filter either downstream or both upstream and downstream. In addition, two types of stand-alone combination filters were evaluated: a bag-type fiberglass filter...... that contained AC and a synthetic fiber cartridge filter that contained AC. Air that had passed through used filters was most acceptable for those sets in which an AC filter was used downstream of the particle filter. Comparable air quality was achieved with the stand-alone bag filter that contained AC...

  11. Stability of Fentanyl Citrate, Hydromorphone Hydrochloride, Ketamine Hydrochloride, Midazolam, Morphine Sulfate, and Pentobarbital Sodium in Polypropylene Syringes.

    Science.gov (United States)

    Anderson, Collin; MacKay, Mark

    2015-12-16

    Determine the stability of fentanyl 10 mcg/mL in 0.9% sodium chloride, fentanyl 10 mcg/mL in 5% dextrose, fentanyl 50 mcg/mL, hydromorphone 100 mcg/mL in 0.9% sodium chloride, ketamine 10 mg/mL, midazolam 0.4 mg/mL in 5% dextrose, midazolam 5 mg/mL, morphine 1 mg/mL in 0.9% sodium chloride, morphine 1 mg/mL in 5% dextrose, and pentobarbital 50 mg/mL when stored as single drug entities at room temperature in polypropylene syringes. Four 5 mL samples of each drug and concentration were prepared in 10 mL polypropylene syringes. The samples were stored at ambient room temperature in a locked cabinet. Triplicate determinations of drug concentration for each sample were performed initially, on day 50 or 51, and on day 100 using high-performance liquid chromatography with diode-array detection. With the exception of the hydromorphone 100 mcg/mL dilution, all compounds were found to contain greater than 95% of their initial concentration remaining at 100 days. Each sample remained clear and colorless when visually inspected.

  12. High-Level Waste Glass Formulation Model Sensitivity Study 2009 Glass Formulation Model Versus 1996 Glass Formulation Model

    International Nuclear Information System (INIS)

    Belsher, J.D.; Meinert, F.L.

    2009-01-01

    This document presents the differences between two HLW glass formulation models (GFM): The 1996 GFM and 2009 GFM. A glass formulation model is a collection of glass property correlations and associated limits, as well as model validity and solubility constraints; it uses the pretreated HLW feed composition to predict the amount and composition of glass forming additives necessary to produce acceptable HLW glass. The 2009 GFM presented in this report was constructed as a nonlinear optimization calculation based on updated glass property data and solubility limits described in PNNL-18501 (2009). Key mission drivers such as the total mass of HLW glass and waste oxide loading are compared between the two glass formulation models. In addition, a sensitivity study was performed within the 2009 GFM to determine the effect of relaxing various constraints on the predicted mass of the HLW glass.

  13. A general model for the dissolution of nuclear waste glasses in salt brine

    International Nuclear Information System (INIS)

    McGrail, B.P.; Strachan, D.M.

    1988-07-01

    A mechanistic model describing a dynamic mass balance between the production and consumption of dissolved silica was found to describe the dissolution of SRL-165 defense waste glass in a high-magnesium (PBB3) brine at a temperature of 90/degree/C. The synergetic effect of the waste package container on the glass dissolution rate was found to depend on a precipitation reaction for a ferrous silicate mineral. The model predicted that the ferrous silicate precipitate should be variable in composition where the iron-silica ratio depended on the metal-to-glass surface area ratio used in the experiment. This prediction was confirmed experimentally by the variable iron-silica ratios observed in filtered leachates. However, the interaction between dissolved silica and iron corrosion products needs to be much better understood before the model could be used with confidence in predicting radionuclide release rates for a salt repository. If the deleterious effects of the iron corrosion products can be shown to be transient, and the fracturing of the glass can be minimized, it appears that the performance of SRL-165 defense waste glass will be near the NRC regulatory criterion for fraction release of one part in 100,000 in PBB3 brine at 90/degree/C under silica-saturated conditions. 47 refs., 6 figs., 1 tab

  14. Spatial filter lens design for the main laser of the National Ignition Facility

    International Nuclear Information System (INIS)

    Korniski, R.J.

    1998-01-01

    The National Ignition Facility (NIF), being designed and constructed at Lawrence Livermore National Laboratory (LLNL), comprises 192 laser beams The lasing medium is neodymium in phosphate glass with a fundamental frequency (1ω) of 1 053microm Sum frequency generation in a pair of conversion crystals (KDP/KD*P) will produce 1 8 megajoules of the third harmonic light (3ω or λ=351microm) at the target The purpose of this paper is to provide the lens design community with the current lens design details of the large optics in the Main Laser This paper describes the lens design configuration and design considerations of the Main Laser The Main Laser is 123 meters long and includes two spatial filters one 13 5 meters and one 60 meters These spatial filters perform crucial beam filtering and relaying functions We shall describe the significant lens design aspects of these spatial filter lenses which allow them to successfully deliver the appropriate beam characteristic onto the target For an overview of NIF please see ''Optical system design of the National Ignition Facility,'' by R Edward English. et al also found in this volume

  15. Optimized Synthesis of Foam Glass from Recycled CRT Panel Glass

    DEFF Research Database (Denmark)

    Petersen, Rasmus Rosenlund; König, Jakob; Yue, Yuanzheng

    Most of the panel glass from cathode ray tubes (CRTs) is landfilled today. Instead of landfilling, the panel glass can be turned into new environment-friendly foam glass. Low density foam glass is an effective heat insulating material and can be produced just by using recycle glass and foaming...... additives. In this work we recycle the CRT panel glass to synthesize the foam glass as a crucial component of building and insulating materials. The synthesis conditions such as foaming temperature, duration, glass particle size, type and concentrations of foaming agents, and so on are optimized...... by performing systematic experiments. In particular, the concentration of foaming agents is an important parameter that influences the size of bubbles and the distribution of bubbles throughout the sample. The foam glasses are characterised regarding density and open/closed porosity. Differential scanning...

  16. DEVELOPMENT OF AG-1 SECTION FI ON METAL MEDIA FILTERS - 9061

    International Nuclear Information System (INIS)

    Adamson, D.; Waggoner, C.A.

    2008-01-01

    Development of a metal media standard (FI) for ASME AG-1 (Code on Nuclear Air and Gas Treatment) has been under way for almost ten years. This paper will provide a brief history of the development process of this section and a detailed overview of its current content/status. There have been at least two points when dramatic changes have been made in the scope of the document due to feedback from the full Committee on Nuclear Air and Gas Treatment (CONAGT). Development of the proposed section has required resolving several difficult issues associated with scope; namely, filtering efficiency, operating conditions (media velocity, pressure drop, etc.), qualification testing, and quality control/acceptance testing. A proposed version of Section FI is currently undergoing final revisions prior to being submitted for balloting. The section covers metal media filters of filtering efficiencies ranging from medium (less than 99.97%) to high (99.97% and greater). Two different types of high efficiency filters are addressed; those units intended to be a direct replacement of Section FC fibrous glass HEPA filters and those that will be placed into newly designed systems capable of supporting greater static pressures and differential pressures across the filter elements. Direct replacements of FC HEPA filters in existing systems will be required to meet equivalent qualification and testing requirements to those contained in Section FC. A series of qualification and quality assurance test methods have been identified for the range of filtering efficiencies covered by this proposed standard. Performance characteristics of sintered metal powder vs. sintered metal fiber media are dramatically different with respect to parameters like differential pressures and rigidity of the media. Wide latitude will be allowed for owner specification of performance criteria for filtration units that will be placed into newly designed systems. Such allowances will permit use of the most

  17. Confocal filtering in cathodoluminescence microscopy of nanostructures

    Science.gov (United States)

    Narváez, Angela C.; Weppelman, I. Gerward C.; Moerland, Robert J.; Hoogenboom, Jacob P.; Kruit, Pieter

    2014-06-01

    Cathodoluminescence (CL) microscopy allows optical characterization of nanostructures at high spatial resolution. At the nanoscale, a main challenge of the technique is related to the background CL generated within the sample substrate. Here, we implement confocal detection of the CL signal to minimize the background contribution to the measurement. Nano-phosphors were used as point sources to evaluate the filtering capabilities of our confocal CL system, obtaining an axial intensity profile with 2.7 μm full width at half maximum for the central peak, in good correspondence with theoretical expectations. Considering the electron interaction volume, we found that the confocal filter becomes effective for electron energies above 20 keV, when using a 25 μm pinhole (0.86 Airy units). To illustrate our approach, we present confocal CL imaging of gold nanowires and triangular shaped plates deposited on an indium-tin oxide covered glass substrate, comparing the images with those obtained in standard unfiltered CL detection. The results show that confocal CL microscopy is a valuable tool for the investigation of nanostructures on highly cathodoluminescent substrates, widely used in biological and optical applications.

  18. Confocal filtering in cathodoluminescence microscopy of nanostructures

    Energy Technology Data Exchange (ETDEWEB)

    Narváez, Angela C., E-mail: a.c.narvaez@tudelft.nl, E-mail: j.p.hoogenboom@tudelft.nl; Weppelman, I. Gerward C.; Moerland, Robert J.; Hoogenboom, Jacob P., E-mail: a.c.narvaez@tudelft.nl, E-mail: j.p.hoogenboom@tudelft.nl; Kruit, Pieter [Imaging Physics, Faculty of Applied Sciences, Delft University of Technology, Lorentzweg 1, 2628CJ Delft (Netherlands)

    2014-06-23

    Cathodoluminescence (CL) microscopy allows optical characterization of nanostructures at high spatial resolution. At the nanoscale, a main challenge of the technique is related to the background CL generated within the sample substrate. Here, we implement confocal detection of the CL signal to minimize the background contribution to the measurement. Nano-phosphors were used as point sources to evaluate the filtering capabilities of our confocal CL system, obtaining an axial intensity profile with 2.7 μm full width at half maximum for the central peak, in good correspondence with theoretical expectations. Considering the electron interaction volume, we found that the confocal filter becomes effective for electron energies above 20 keV, when using a 25 μm pinhole (0.86 Airy units). To illustrate our approach, we present confocal CL imaging of gold nanowires and triangular shaped plates deposited on an indium-tin oxide covered glass substrate, comparing the images with those obtained in standard unfiltered CL detection. The results show that confocal CL microscopy is a valuable tool for the investigation of nanostructures on highly cathodoluminescent substrates, widely used in biological and optical applications.

  19. Influence of phosphate glass recrystallization on the stability of a waste matrix to leaching

    Science.gov (United States)

    Yudintsev, S. V.; Pervukhina, A. M.; Mokhov, A. V.; Malkovsky, V. I.; Stefanovsky, S. V.

    2017-04-01

    In Russia, highly radioactive liquid wastes from recycling of spent fuel of nuclear reactors are solidified into Na-Al-P glass for underground storage. The properties of the matrix including the radionuclide fixation will change with time due to crystallization. This is supported by the results of study of the interaction between glassy matrices, products of their crystallization, and water. The concentration of Cs in a solution at the contact of a recrystallized sample increased by three orders of magnitude in comparison with an experiment with glass. This difference is nearly one order of magnitude for Sr, Ce, and Nd (simulators of actinides) and U due to their incorporation into phases with low solubility in water. Based on data on the compositional change of solutions after passing through filters of various diameters, it is concluded that Cs occurs in the dissolved state in runs with a glass and recrystallized matrix. At the same time, Sr, lanthanides, and U occur in the dissolved state and in the composition of colloids in runs with glass, and mostly in colloid particles after contact with the recrystallized sample. These results should be regarded for substantiation of safety for geological waste storage.

  20. TECHNICAL FACT SHEET: A Systematic Evaluation of Dissolved Metals Loss during Water Sample Filtration

    Science.gov (United States)

    This research study examined how water quality collection and filtration approaches, including commonly used capsule and disc syringe filters, may cause losses in the amounts of soluble lead and copper found in a sample. A variety of commercially available filter materials with a...

  1. Recycling of Glass

    DEFF Research Database (Denmark)

    Christensen, Thomas Højlund; Damgaard, Anders

    2011-01-01

    Glass is used for many purposes, but in the waste system glass is predominantly found in terms of beverage and food containers with a relatively short lifetime before ending up in the waste. Furthermore there is a large amount of flat glass used in building materials which also ends up in the waste...... system; this glass though has a long lifetime before ending up in the waste. Altogether these product types add up to 82% of the production of the European glass industry (IPCC, 2001). Recycling of glass in terms of cleaning and refilling of bottles as well as the use of broken glass in the production...... of new glass containers is well established in the glass industry. This chapter describes briefly howglass is produced and howwaste glass is recycled in the industry. Quality requirements and use of recycled products are discussed, as are the resource and environmental issues of glass recycling....

  2. Evaluation of secondary electron filter for removing contaminant electrons from high-energy 6 MV x-ray beam

    International Nuclear Information System (INIS)

    Kumagai, Kozo

    1988-01-01

    When using high energy X-rays, the dose increases at the skin surface and build-up region of beam contamination of secondary electrons coming out from the inner surface of the lineac head. At our radiotherapy department, many cases of external otitis from severe skin reactions, particularly resulting from whole brain irradiation of primary and metastatic brain tumors with a 6 MV X-ray lineac, have been encountered. An investigation was made of the physical aspects of a 6 MV X-ray beam using three electron filters, lead lucite, lead glass and lucite to remove secondary electrons. Transparent materials for filters should be preferable for locating the light field. The following results were obtained: 1) For removing secondary electrons, a lead lucite filter was found best. 2) The lead lucite filter proved most effective for removing secondary electrons from the area of treatment. It reduced the dose of irradiation to the skin surface and build-up region, and furthermore improved the depth dose relative to that without filters. 3) From a clinical standpoint, skin reactions such as external otitis remarkably decreased using a lead lucite filter. 4) It thus appears necessary to use a high energy X-ray with newly designed filters to reduce beam contamination of secondary electrons. (author)

  3. Inventário de ciclo de vida da manufatura de seringas odontológicas Life cycle inventory of dental syringes

    Directory of Open Access Journals (Sweden)

    Biagio F. Giannetti

    2008-01-01

    Full Text Available Uma das formas mais integradas, completas e eficazes para a gestão ambiental de atividades produtivas é baseada no ciclo de vida do produto, sendo a Avaliação do Ciclo de Vida sua principal ferramenta. O produto avaliado é a seringa odontológica tipo Carpule. O objetivo é a realização do Inventário de Ciclo de Vida (ICV simplificado da fabricação de seringas odontológicas tipo Carpule, visando quantificar o uso de energia elétrica e a emissão de resíduos sólidos desde a mineração até o descarte do produto. A estrutura metodológica está baseada nas normas da série NBR ISO 14.040 e ISO 14.040. As fronteiras do estudo incluem as etapas de mineração, beneficiamento e manufatura; a produção do polietileno que compõe o tubete e a embalagem da agulha; a produção do aço, utilizado na fabricação da agulha, e o uso do conjunto pelos dentistas. A unidade funcional utilizada é 10(6 (um milhão de anestesias aplicadas. Na avaliação de melhorias, as soluções propostas permitem reduzir o consumo de energia elétrica em aproximadamente 20% na etapa de manufatura. A quantidade de resíduos sólidos pode ser reduzida de 40% na etapa de manufatura, o que corresponde a aproximadamente 6,50% do total de resíduos sólidos no ciclo de vida da seringa odontológica.Among the methods proposed to environmental management of productive activities, Life Cycle Assessment is one of the most integrated, complete and efficacious. The product assessed is the dental carpule syringe. The aim of this work is to to perform a Streamlined Life Cycle Inventory (LCI to quantify the electric energy consumption and the solid waste release from dental carpule syringes manufacture. The methodological structure is based on NBR ISO 14.040 and ISO 14.040 series. The LCI covers the syringe life cycle from mining to disposal. The limits of the system include the stages of copper and zinc mining and ore beneficiation; the production of polyethylene used for

  4. Thermo-tunable hybrid photonic crystal fiber based on solution-processed chalcogenide glass nanolayers

    DEFF Research Database (Denmark)

    Markos, Christos

    2016-01-01

    the air-capillaries of the fiber based on a solution-processed glass approach. The deposited high-index layers revealed antiresonant transmission windows from similar to 500 nm up to similar to 1300 nm. We experimentally demonstrate for the first time the possibility to thermally-tune the revealed....../degrees C at 1300 nm. The proposed fiber device could potentially constitute an efficient route towards realization of monolithic tunable fiber filters or sensing elements....

  5. The Great American Eclipse Glasses Debacle of 2017

    Science.gov (United States)

    Tresch Fienberg, Richard; AAS Solar Eclipse Task Force

    2018-01-01

    In 2014, looking ahead to the “Great American” solar eclipse of 21 August 2017, the American Astronomical Society established the AAS Solar Eclipse Task Force to help prepare the public for a safe and enjoyable experience. We worked with NASA and several associations of eye-care professionals to come up a safety message that we could all stand behind. The gist of it was that it is perfectly safe to view totality without protection, but when any part of the Sun’s bright face is exposed, you must view through eclipse glasses or handheld viewers that meet the ISO 12312-2 international safety standard for filters for direct viewing of the Sun. We compiled a list of manufacturers whose products we knew to meet the standard (because we examined their test data) and posted it on our website. These manufacturers were all based in the US or Europe. A few weeks before the eclipse, reports surfaced of viewers purchased on Amazon.com labeled “Made in China” or that were obvious knock-offs of US manufacturers’ products. Amazon responded by suspending virtually all sales of eclipse viewers and recalling many of units already sold and shipped. Millions of people who’d bought eclipse glasses online, whether from legitimate sources or from bad actors, were unsure whether they could trust their purchases. We had to change our safety messaging: it was no longer sufficient to tell people to look for the ISO 12312-2 label, because that was being printed on Chinese-made glasses that hadn’t actually been shown to meet the standard. Instead, the only way to know that you had safe viewers was to know that you got them from a legitimate source — which meant we had to expand the list on our website to include every legitimate seller we could identify. Doing so required a monumental effort under intense time pressure. Thankfully there were few reports of eye injuries following the eclipse, but apparently many people who otherwise would have viewed the eclipse chose to skip

  6. NEW ERBIUM DOPED ANTIMONY GLASSES FOR LASER AND GLASS AMPLIFICATION

    Directory of Open Access Journals (Sweden)

    B. Tioua

    2015-07-01

    Full Text Available Because of the special spectroscopic properties of the rare earth ions, rare earth doped glasses are widely used in bulk and fiber lasers or amplifiers. The modelling of lasers and searching for new laser transitions require a precise knowledge of the spectroscopic properties of rare earth ions in different host glasses. In this poster will offer new doped erbium glasses synthesized in silicate crucibles were obtained in the combination Sb2O3-WO3-Na2O. Several properties are measured and correlated with glass compositions. The absorption spectral studies have been performed for erbium doped glasses. The intensities of various absorption bands of the doped glasses are measured and the Judd-Ofelt parameters have been computed. From the theory of Judd-Ofelt, various radiative properties, such as transition probability, branching ratio and radiative life time for various emission levels of these doped glasses have been determined and reported. These results confirm the ability of antimony glasses for glass amplification.

  7. Influence of Glass Property Restrictions on Hanford HLW Glass Volume

    International Nuclear Information System (INIS)

    Kim, Dong-Sang; Vienna, John D.

    2001-01-01

    A systematic evaluation of Hanford High-Level Waste (HLW) loading in alkali-alumino-borosilicate glasses was performed. The waste feed compositions used were obtained from current tank waste composition estimates, Hanford's baseline retrieval sequence, and pretreatment processes. The waste feeds were sorted into groups of like composition by cluster analysis. Glass composition optimization was performed on each cluster to meet property and composition constraints while maximizing waste loading. Glass properties were estimated using property models developed for Hanford HLW glasses. The impacts of many constraints on the volume of HLW glass to be produced at Hanford were evaluated. The liquidus temperature, melting temperature, chromium concentration, formation of multiple phases on cooling, and product consistency test response requirements for the glass were varied one- or many-at-a-time and the resultant glass volume was calculated. This study shows clearly that the allowance of crystalline phases in the glass melter can significantly decrease the volume of HLW glass to be produced at Hanford.

  8. Phase transitions and glass transition in a hyperquenched silica–alumina glass

    DEFF Research Database (Denmark)

    Zhang, Y.F.; Zhao, D.H.; Yue, Yuanzheng

    2017-01-01

    We investigate phase transitions, glass transition, and dynamic behavior in the hyperquenched 69SiO2–31Al2O3 (mol%) glass (SA glass). Upon reheating, the SA glass exhibits a series of thermal responses. Subsequent to the sub-Tg enthalpy release, the glass undergoes a large jump in isobaric heat...... capacity (ΔCp) during glass transition, implying the fragile nature of the SA glass. The mullite starts to form before the end of glass transition, indicating that the SA glass is extremely unstable against crystallization. After the mullite formation, the remaining glass phase exhibits an increased Tg...... and a suppressed ΔCp. The formation of cristobalite at 1553 K indicates the dominance of silica in the remaining glass matrix. The cristobalite gradually re-melts as the isothermal heat-treatment temperature is raised from 1823 to 1853 K, which is well below the melting point of cristobalite, while the amount...

  9. Glass sealing

    Energy Technology Data Exchange (ETDEWEB)

    Brow, R.K.; Kovacic, L.; Chambers, R.S. [Sandia National Labs., Albuquerque, NM (United States)

    1996-04-01

    Hernetic glass sealing technologies developed for weapons component applications can be utilized for the design and manufacture of fuel cells. Design and processing of of a seal are optimized through an integrated approach based on glass composition research, finite element analysis, and sealing process definition. Glass sealing procedures are selected to accommodate the limits imposed by glass composition and predicted calculations.

  10. Filter arrays

    Science.gov (United States)

    Page, Ralph H.; Doty, Patrick F.

    2017-08-01

    The various technologies presented herein relate to a tiled filter array that can be used in connection with performance of spatial sampling of optical signals. The filter array comprises filter tiles, wherein a first plurality of filter tiles are formed from a first material, the first material being configured such that only photons having wavelengths in a first wavelength band pass therethrough. A second plurality of filter tiles is formed from a second material, the second material being configured such that only photons having wavelengths in a second wavelength band pass therethrough. The first plurality of filter tiles and the second plurality of filter tiles can be interspersed to form the filter array comprising an alternating arrangement of first filter tiles and second filter tiles.

  11. Analysis of early medieval glass beads - Glass in the transition period

    Energy Technology Data Exchange (ETDEWEB)

    Smit, Ziga, E-mail: ziga.smit@ijs.si [Faculty of Mathematics and Physics, University of Ljubljana, Jadranska 19, SI-1000 Ljubljana (Slovenia); Jozef Stefan Institute, Jamova 39, P.O.B. 3000, SI-1001 Ljubljana (Slovenia); Knific, Timotej [National Museum of Slovenia, Presernova 20, SI-1000 Ljubljana (Slovenia); Jezersek, David [Jozef Stefan Institute, Jamova 39, P.O.B. 3000, SI-1001 Ljubljana (Slovenia); Istenic, Janka [National Museum of Slovenia, Presernova 20, SI-1000 Ljubljana (Slovenia)

    2012-05-01

    Glass beads from graves excavated in Slovenia and dated archaeologically to the 7th-10th century AD were analysed by the combined PIXE-PIGE method. The results indicate two groups of glass; natron glass made in the Roman tradition and glass made with alkalis from the ash of halophytic plants, which gradually replaced natron glass after c. 800 AD. The alkalis used in the second group of glass seem to be in close relation to a variant of the Venetian white glass that appeared several centuries later. The origin of this glass may be traced to glass production in Mesopotamia and around the Aral Sea. All the mosaic beads with eye decoration, as well as most of the drawn-segmented and drawn-cut beads analysed, are of plant-ash glass, which confirms their supposed oriental origin.

  12. INJECTING EQUPMENT SHARING AND PERCEPTION OF HIV AND HEPATITIS RISK AMONG INJECTING DRUG USERS IN BUDAPEST

    Science.gov (United States)

    Gyarmathy, V. Anna; Neaigus, Alan; Ujhelyi, Eszter

    2008-01-01

    In Central European states, rates of HIV among IDUs have been low although HCV infection is widespread. The goal of our study was to assess HIV infection, risk perceptions and injecting equipment sharing among injection drug users in Budapest, Hungary. Altogether 150 IDUs were interviewed (121 structured between 1999-2000 and 29 ethnographic between 2003-2004). The majority of them injected heroin (52% and 79%) and many injected amphetamines (51% and 35%). One person tested positive for HIV. Two thirds (68% of 121) shared injecting equipment (syringes, cookers and filters). Some participants said they shared syringes because they were not carrying them for fear of police harassment, and that they reused filters as a backup drug supply. In multivariate analysis, sharing of injecting equipment was associated with higher perceived susceptibility to HIV/AIDS, lower self-efficacy for sterile equipment use, higher motivation to comply with peer pressure to use dirty injecting equipment, and with having a criminal record. The high levels of injecting risk behaviors found in this study are a cause for serious concern. HIV prevention interventions need to address not only sharing syringes but also sharing and reusing other injecting equipment and drug filters. PMID:17129858

  13. Metal-organic framework based in-syringe solid-phase extraction for the on-site sampling of polycyclic aromatic hydrocarbons from environmental water samples.

    Science.gov (United States)

    Zhang, Xiaoqiong; Wang, Peiyi; Han, Qiang; Li, Hengzhen; Wang, Tong; Ding, Mingyu

    2018-04-01

    In-syringe solid-phase extraction is a promising sample pretreatment method for the on-site sampling of water samples because of its outstanding advantages of portability, simple operation, short extraction time, and low cost. In this work, a novel in-syringe solid-phase extraction device using metal-organic frameworks as the adsorbent was fabricated for the on-site sampling of polycyclic aromatic hydrocarbons from environmental waters. Trace polycyclic aromatic hydrocarbons were effectively extracted through the self-made device followed by gas chromatography with mass spectrometry analysis. Owing to the excellent adsorption performance of metal-organic frameworks, the analytes could be completely adsorbed during one adsorption cycle, thus effectively shortening the extraction time. Moreover, the adsorbed analytes could remain stable on the device for at least 7 days, revealing the potential of the self-made device for on-site sampling of degradable compounds in remote regions. The limit of detection ranged from 0.20 to 1.9 ng/L under the optimum conditions. Satisfactory recoveries varying from 84.4 to 104.5% and relative standard deviations below 9.7% were obtained in real samples analysis. The results of this study promote the application of metal-organic frameworks in sample preparation and demonstrate the great potential of in-syringe solid-phase extraction for the on-site sampling of trace contaminants in environmental waters. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Syringe needle skull penetration reduces brain injuries and secondary inflammation following intracerebral neural stem cell transplantation

    OpenAIRE

    Gao, Mou; Dong, Qin; Zhang, Hongtian; Yang, Yang; Zhu, Jianwei; Yang, Zhijun; Xu, Minhui; Xu, Ruxiang

    2017-01-01

    Intracerebral neural stem cell (NSC) transplantation is beneficial for delivering stem cell grafts effectively, however, this approach may subsequently result in brain injury and secondary inflammation. To reduce the risk of promoting brain injury and secondary inflammation, two methods were compared in the present study. Murine skulls were penetrated using a drill on the left side and a syringe needle on the right. Mice were randomly divided into three groups (n=84/group): Group A, receiving...

  15. Nepheline Crystallization in Nuclear Waste Glasses: Progress toward acceptance of high-alumina formulations

    International Nuclear Information System (INIS)

    McCloy, John S.; Schweiger, Michael J.; Rodriguez, Carmen P.; Vienna, John D.

    2011-01-01

    We have critically compiled and analyzed historical data for investigating the quantity of nepheline (NaAlSiO4) precipitation as a function of composition in simulated nuclear waste glasses. To understand composition we used two primary methods: (1) investigating the Al2O3-SiO2-Na2O ternary with filtering for different B2O3 levels and (2) creating a quadrant system consisting of compositions reduced to two metric numbers. These metrics are (1) the nepheline discriminator (ND) which depends only on the SiO2 content by weight normalized to the total weight of the Al2O3-SiO2-Na2O sub-mixture and (2) the optical basicity (OB) which contains contributions from all constituents in the glass. Nepheline precipitation is expected to be suppressed at high SiO2 levels (ND >0.62) or at low basicities (OB 5 wt% B2O3. The OB concept can help further refine regions of nepheline-free glass formation.

  16. Error Measurements in an Acousto-Optic Tunable Filter Fiber Bragg Grating Sensor System

    Science.gov (United States)

    1994-05-01

    for an ideal AOTF, at 833 and 838 nm using a TeO2 crystal ............................ 33 Figure 3.12. Frequency characteristics of Equation (3.43...multiple channels in an AOTF requires the presence of multiple RF frequencies to establish the complex grating. Since the crystal used in the AOTF ( TeO2 ) is...in germano- silicate glass . This index modulation, Bragg grating, acts as an optical band rejection filter for those wavelengths that meet the Bragg

  17. Single- and multi-pulse femtosecond laser ablation of optical filter materials

    International Nuclear Information System (INIS)

    Krueger, J.; Lenzner, M.; Martin, S.; Lenner, M.; Spielmann, C.; Fiedler, A.; Kautek, W.

    2003-01-01

    Ablation experiments employing Ti:sapphire laser pulses with durations from 30 to 340 fs (centre wavelength 800 nm, repetition rate 1 kHz) were performed in air. Absorbing filters (Schott BG18 and BG36) served as targets. The direct focusing technique was used under single- and multi-pulse irradiation conditions. Ablation threshold fluences were determined from a semi-logarithmic plot of the ablation crater diameter versus laser fluence. The threshold fluence decreases for a shorter pulse duration and an increasing number of pulses. The multi-pulse ablation threshold fluences are similar to those of undoped glass material (∼1 J cm -2 ). That means that the multi-pulse ablation threshold is independent on the doping level of the filters. For more than 100 pulses per spot and all pulse durations applied, the threshold fluence is practically constant. This leads to technically relevant ablation threshold values

  18. Determination of ammonium in aqueous samples using new headspace dynamic in-syringe liquid-phase microextraction with in situ derivitazation coupled with liquid chromatography-fluorescence detection.

    Science.gov (United States)

    Muniraj, Sarangapani; Yan, Cheing-Tong; Shih, Hou-Kung; Ponnusamy, Vinoth Kumar; Jen, Jen-Fon

    2012-11-19

    A new simultaneous derivatization and extraction method for the preconcentration of ammonia using new one-step headspace dynamic in-syringe liquid-phase microextraction with in situ derivatization was developed for the trace determination of ammonium in aqueous samples by liquid chromatography with fluorescence detection (LC-FLD). The acceptor phase (as derivatization reagent) containing o-phthaldehyde and sodium sulfite was held within a syringe barrel and immersed in the headspace of sample container. The gaseous ammonia from the alkalized aqueous sample formed a stable isoindole derivative with the acceptor phase inside the syringe barrel through the reciprocated movements of plunger. After derivatization-cum-extraction, the acceptor phase was directly injected into LC-FLD for analysis. Parameters affecting the ammonia evolution and the extraction/derivatization efficiency such as sample matrix, pH, temperature, sampling time, and the composition of derivatization reagent, reaction temperature, and frequency of reciprocated plunger, were studied thoroughly. Results indicated that the maximum extraction efficiency was obtained by using 100μL derivatization reagent in a 1-mL gastight syringe under 8 reciprocated movements of plunger per min to extract ammonia evolved from a 20mL alkalized aqueous solution at 70°C (preheated 4min) with 380rpm stirring for 8min. The detection was linear in the concentration range of 0.625-10μM with the correlation coefficient of 0.9967 and detection limit of 0.33μM (5.6ng mL(-1)) based on SN(-1)=3. The method was applied successfully to determine ammonium in real water samples without any prior cleanup of the samples, and has been proved to be a simple, sensitive, efficient and cost-effective procedure for trace ammonium determination in aqueous samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Spherical 2+p spin-glass model: An exactly solvable model for glass to spin-glass transition

    International Nuclear Information System (INIS)

    Crisanti, A.; Leuzzi, L.

    2004-01-01

    We present the full phase diagram of the spherical 2+p spin-glass model with p≥4. The main outcome is the presence of a phase with both properties of full replica symmetry breaking phases of discrete models, e.g., the Sherrington-Kirkpatrick model, and those of one replica symmetry breaking. This phase has a finite complexity which leads to different dynamic and static properties. The phase diagram is rich enough to allow the study of different kinds of glass to spin glass and spin glass to spin glass phase transitions

  20. Glass binder development for a glass-bonded sodalite ceramic waste form

    International Nuclear Information System (INIS)

    Riley, Brian J.; Vienna, John D.; Frank, Steven M.; Kroll, Jared O.; Peterson, Jacob A.

    2017-01-01

    This paper discusses work to develop Na_2O-B_2O_3-SiO_2 glass binders for immobilizing LiCl-KCl eutectic salt waste in a glass-bonded sodalite waste form following electrochemical reprocessing of used metallic nuclear fuel. In this paper, five new glasses with ~20 mass% Na_2O were designed to generate waste forms with high sodalite. The glasses were then used to produce ceramic waste forms with a surrogate salt waste. The waste forms made using these new glasses were formulated to generate more sodalite than those made with previous baseline glasses for this type of waste. The coefficients of thermal expansion for the glass phase in the glass-bonded sodalite waste forms made with the new binder glasses were closer to the sodalite phase in the critical temperature region near and below the glass transition temperature than previous binder glasses used. Finally, these improvements should result in lower probability of cracking in the full-scale monolithic ceramic waste form, leading to better long-term chemical durability.

  1. Filter-fluorescer x-ray spectrometer using solid state detectors for γ-ray background reduction

    International Nuclear Information System (INIS)

    Yokoi, Takashi; Kitagawa, Yoneyoshi; Shiraga, Hiroyuki; Matsunaga, Hirohide; Kato, Yoshiaki; Yamanaka, Chiyoe.

    1986-01-01

    Filter-fluorescer x-ray spectrometer using solid state photo-detectors instead of the photomultiplier tubes in order to reduce the γ-ray background noise is reported. A significant reduction of the γ-ray background noise is expected, because solid state photo-detectors are very small in size compared with the photomultiplier tubes. It has been confirmed that the γ-ray background is reduced in the target irradiation experiments with the Gekko MII glass laser. (author)

  2. Using physical properties of molten glass to estimate glass composition

    International Nuclear Information System (INIS)

    Choi, Kwan Sik; Yang, Kyoung Hwa; Park, Jong Kil

    1997-01-01

    A vitrification process is under development in KEPRI for the treatment of low-and medium-level radioactive waste. Although the project is for developing and building Vitrification Pilot Plant in Korea, one of KEPRI's concerns is the quality control of the vitrified glass. This paper discusses a methodology for the estimation of glass composition by on-line measurement of molten glass properties, which could be applied to the plant for real-time quality control of the glass product. By remotely measuring viscosity and density of the molten glass, the glass characteristics such as composition can be estimated and eventually controlled. For this purpose, using the database of glass composition vs. physical properties in isothermal three-component system of SiO 2 -Na 2 O-B 2 O 3 , a software TERNARY has been developed which determines the glass composition by using two known physical properties (e.g. density and viscosity)

  3. Fabrication of slag-glass composite with controlled porosity

    Directory of Open Access Journals (Sweden)

    Ranko Adziski

    2008-06-01

    Full Text Available The preparation and performance of porous ceramics made from waste materials were investigated. Slag from thermal electrical plant Kakanj (Bosnia and Herzegovina with defined granulations: (0.500÷0.250 mm; (0.250÷0.125 mm; (0.125÷0.063 mm; (0.063÷0.045 mm and 20/10 wt.% of the waste TV screen glass with a granulation <0.063 mm were used for obtaining slag-glass composites with controlled porosity. The one produced from the slag powder fraction (0.125÷0.063 mm and 20 wt.% TV screen glass, sintered at 950°C/2h, was considered as the optimal. This system possesses open porosity of 26.8±1.0%, and interconnected pores with the size of 250–400 μm. The values of E-modulus and bending strength of this composite were 10.6±0.6 GPa and 45.7±0.7 MPa, respectively. The coefficient of thermal expansion was 8.47·10-6/°C. The mass loss in 0.1M HCl solution after 30 days was 1.2 wt.%. The permeability and the form coefficient of the porous composite were K0=0.12 Da and C0=4.53·105 m-1, respectively. The porous composite shows great potential to be used as filters, diffusers for water aeration, dust collectors, acoustic absorbers, etc.

  4. Microstructuring of glasses

    CERN Document Server

    Hülsenberg, Dagmar; Bismarck, Alexander

    2008-01-01

    As microstructured glass becomes increasingly important for microsystems technology, the main application fields include micro-fluidic systems, micro-analysis systems, sensors, micro-actuators and implants. And, because glass has quite distinct properties from silicon, PMMA and metals, applications exist where only glass devices meet the requirements. The main advantages of glass derive from its amorphous nature, the precondition for its - theoretically - direction-independent geometric structurability. Microstructuring of Glasses deals with the amorphous state, various glass compositions and their properties, the interactions between glasses and the electromagnetic waves used to modify it. Also treated in detail are methods for influencing the geometrical microstructure of glasses by mechanical, chemical, thermal, optical, and electrical treatment, and the methods and equipment required to produce actual microdevices.

  5. Digital Simulation of a Hybrid Active Filter - An Active Filter in Series with a Shunt Passive Filter

    OpenAIRE

    Sitaram, Mahesh I; Padiyar, KR; Ramanarayanan, V

    1998-01-01

    Active filters have long been in use for the filtering of power system load harmonics. In this paper, the digital simulation results of a hybrid active power filter system for a rectifier load are presented. The active filter is used for filtering higher order harmonics as the dominant harmonics are filtered by the passive filter. This reduces the rating of the active filter significantly. The DC capacitor voltage of the active filter is controlled using a PI controller.

  6. Evaluation of the Performance of Iodine-Treated Biocidal Filters Under the Influence of Environmental Parameters

    Science.gov (United States)

    2013-02-01

    ventilation and air conditioning (HVAC) filters made of polyethylene –polypropylene and of a synthetic polymer were compared with a glass microfiber...airborne pathogens. 2.2.2. Viral Aerosols Bioaerosols are airborne particles with biological origins, such as nonviable pollen, and viable fungi ...heterogeneous airborne bacteria and fungi at 600 W for four periods of 2.5 min, each separated by 5 min from the next. Elhafi et al. (2004) demonstrated

  7. Dense grid of narrow bandpass filters for the JST/T250 telescope: summary of results

    Science.gov (United States)

    Brauneck, Ulf; Sprengard, Ruediger; Bourquin, Sebastien; Marín-Franch, Antonio

    2018-01-01

    On the Javalambre mountain in Spain, the Centro de Estudios de Fisica del Cosmos de Aragon has setup two telescopes, the JST/T250 and the JAST/T80. The JAST/T80 telescope integrates T80Cam, a large format, single CCD camera while the JST/T250 will mount the JPCam instrument, a 1.2Gpix camera equipped with a 14-CCD mosaic using the new large format e2v 9.2k×9.2k 10-μm pixel detectors. Both T80Cam and JPCam integrate a large number of filters in dimensions of 106.8×106.8 mm2 and 101.7×95.5 mm2, respectively. For this instrument, SCHOTT manufactured 56 specially designed steep edged bandpass interference filters, which were recently completed. The filter set consists of bandpass filters in the range between 348.5 and 910 nm and a longpass filter at 915 nm. Most of the filters have full-width at half-maximum (FWHM) of 14.5 nm and a blocking between 250 and 1050 nm with optical density of OD5. Absorptive color glass substrates in combination with interference filters were used to minimize residual reflection in order to avoid ghost images. In spite of containing absorptive elements, the filters show the maximum possible transmission. This was achieved by using magnetron sputtering for the filter coating process. The most important requirement for the continuous photometric survey is the tight tolerancing of the central wavelengths and FWHM of the filters. This insures each bandpass has a defined overlap with its neighbors. A high image quality required a low transmitted wavefront error (<λ/4 locally and <λ/2 on the whole aperture), which was achieved even by combining two or three substrates. We report on the spectral and interferometric results measured on the whole set of filters.

  8. PLASTIC AND GLASS GREENHOUSES DETECTION AND DELINEATION FROM WORLDVIEW-2 SATELLITE IMAGERY

    Directory of Open Access Journals (Sweden)

    D. Koc-San

    2016-06-01

    Full Text Available Greenhouse detection using remote sensing technologies is an important research area for yield estimation, sustainable development, urban and rural planning and management. An approach was developed in this study for the detection and delineation of greenhouse areas from high resolution satellite imagery. Initially, the candidate greenhouse patches were detected using supervised classification techniques. For this purpose, Maximum Likelihood (ML, Random Forest (RF, and Support Vector Machines (SVM classification techniques were applied and compared. Then, sieve filter and morphological operations were performed for improving the classification results. Finally, the obtained candidate plastic and glass greenhouse areas were delineated using boundary tracing and Douglas Peucker line simplification algorithms. The proposed approach was implemented in the Kumluca district of Antalya, Turkey utilizing pan-sharpened WorldView-2 satellite imageries. Kumluca is the prominent district of Antalya with greenhouse cultivation and includes both plastic and glass greenhouses intensively. When the greenhouse classification results were analysed, it can be stated that the SVM classification provides most accurate results and RF classification follows this. The SVM classification overall accuracy was obtained as 90.28%. When the greenhouse boundary delineation results were considered, the plastic greenhouses were delineated with 92.11% accuracy, while glass greenhouses were delineated with 80.67% accuracy. The obtained results indicate that, generally plastic and glass greenhouses can be detected and delineated successfully from WorldView-2 satellite imagery.

  9. Comparative study of photocatalytic oxidation on the degradation of formaldehyde and fuzzy mathematics evaluation of filters

    Science.gov (United States)

    Yu, Huili; Zhang, Jieting

    2012-04-01

    In this study, formaldehyde, one of the major volatile organic compounds, is chosen as the target pollutant. The polytetrafluoroethylene (PTFE) filter, a low cost and commonly used material in industry, is employed as the substrate for nano TiO2 photocatalyst coating at room temperature, which has been scarcely used compared to ceramics or glass beads. Furthermore, a specific experimental set-up that is similar to actual air purification system is developed for the testing. The degradation mechanisms of photolysis reaction, adsorption and photocatalytic oxidation reaction on volatile organic compounds are present respectively. The influences of three aspects mentioned above are compared by a serial of experimental data. The high efficiency of volatile organic compounds on the degradation of formaldehyde is assured. Furthermore, the purification characteristics of three kinds of activated carbon filters and PTFE filter with nano TiO2 are evaluated with the method of fuzzy mathematics. In the end, the result shows that the filter with nano TiO2 has the optimal comprehensive performances.

  10. Mass extraction container closure integrity physical testing method development for parenteral container closure systems.

    Science.gov (United States)

    Yoon, Seung-Yil; Sagi, Hemi; Goldhammer, Craig; Li, Lei

    2012-01-01

    Container closure integrity (CCI) is a critical factor to ensure that product sterility is maintained over its entire shelf life. Assuring the CCI during container closure (C/C) system qualification, routine manufacturing and stability is important. FDA guidance also encourages industry to develop a CCI physical testing method in lieu of sterility testing in a stability program. A mass extraction system has been developed to check CCI for a variety of container closure systems such as vials, syringes, and cartridges. Various types of defects (e.g., glass micropipette, laser drill, wire) were created and used to demonstrate a detection limit. Leakage, detected as mass flow in this study, changes as a function of defect length and diameter. Therefore, the morphology of defects has been examined in detail with fluid theories. This study demonstrated that a mass extraction system was able to distinguish between intact samples and samples with 2 μm defects reliably when the defect was exposed to air, water, placebo, or drug product (3 mg/mL concentration) solution. Also, it has been verified that the method was robust, and capable of determining the acceptance limit using 3σ for syringes and 6σ for vials. Sterile products must maintain their sterility over their entire shelf life. Container closure systems such as those found in syringes and vials provide a seal between rubber and glass containers. This seal must be ensured to maintain product sterility. A mass extraction system has been developed to check container closure integrity for a variety of container closure systems such as vials, syringes, and cartridges. In order to demonstrate the method's capability, various types of defects (e.g., glass micropipette, laser drill, wire) were created in syringes and vials and were tested. This study demonstrated that a mass extraction system was able to distinguish between intact samples and samples with 2 μm defects reliably when the defect was exposed to air, water

  11. lead glass brick

    CERN Multimedia

    When you look through the glass at a picture behind, the picture appears raised up because light is slowed down in the dense glass. It is this density (4.06 gcm-3) that makes lead glass attractive to physicists. The refractive index of the glass is 1.708 at 400nm (violet light), meaning that light travels in the glass at about 58% its normal speed. At CERN, the OPAL detector uses some 12000 blocks of glass like this to measure particle energies.

  12. Evaluation of syringe shield effectiveness in handling radiopharmaceuticals

    Directory of Open Access Journals (Sweden)

    Cho Yong-In

    2015-01-01

    Full Text Available The purpose of this study was to evaluate the effectiveness of the radiation shield of radionuclide syringes and the personal dose equivalent by performing a simulation of radionuclides used in nuclear medicine diagnosis. In order to evaluate the dose depending on the distance between the radiation source and the ICRU sphere against the thickness of the shielding device, the distance at which a nuclear medicine worker may inadvertently come into contact with radiation from the radiation source was set at 0 cm to 30 cm according to the thickness of the shield, thus fixing the ICRU sphere. For a dose evaluation, Hp(10, Hp(3, and Hp(0.07 measurable in specific depth of the ICRU were evaluated. It was found that a dose measured on skin surface of nuclear medicine workers was relatively higher, that the dose varied in relation to the thickness of the radiation shield, and that the shielding effect decreased for some radiation sources such as 67Ga and 111In. It proved necessary to increase thickness of shielding device to the radiation sources such as 67Ga and 111In. It is also considered that a study of proper shielding thickness will be needed in future.

  13. Contrasting the magnetic response between magnetic-glass and reentrant spin-glass

    OpenAIRE

    Roy, S. B.; Chattopadhyay, M. K.

    2008-01-01

    Magnetic-glass is a recently identified phenomenon in various classes of magnetic systems undergoing a first order magnetic phase transition. We shall highlight here a few experimentally determined characteristics of magnetic-glass and the relevant set of experiments, which will enable to distinguish a magnetic-glass unequivocally from the well known phenomena of spin-glass and reentrant spin-glass.

  14. Two syringe spinal anesthesia technique for cesarean section: A controlled randomized study of a simple way to achieve more satisfactory block and less hypotension.

    Science.gov (United States)

    Keera, Amr Aly Ismail; Elnabtity, Ali Mohamed Ali

    2016-01-01

    Multiple trials have been tried to prevent hypotension during spinal anesthesia. However, the drug choice and mode of administration is still a matter of debate. To compare the outcome of spinal injection of hyperbaric bupivacaine and fentanyl separately to standard injection of mixed fentanyl with hyperbaric bupivacaine. A randomized, controlled clinical trial. One hundred twenty-four parturient scheduled for elective cesarean section were randomly allocated into two groups, each 62 parturient: Group M received spinal anesthesia using 10 mg bupivacaine 0.5% premixed with 25 μg fentanyl in the same syringe and Group S received 25 μg fentanyl in one syringe and 10 mg bupivacaine 0.5% without barbotage in a second syringe. Patients with intraoperative pain that was controllable without the need for a shift to general anesthesia was significantly lower in Group S (3.2%) than in Group M (16.1%). The frequency of hypotension was significantly lower in Group S compared to Group M (P 0.05). There was no significant difference in the time till occurrence of hypotension, duration of hypotension, mean dose of ephedrine used for the treatment of hypotension and frequency of patients developed itching between the groups (P > 0.05). Separate intrathecal injection of fentanyl and hyperbaric bupivacaine provided a significant improvement in the quality of sensory block and significant reduction of the frequency of hypotension compared to injection of mixed medications.

  15. Comparison of a model vapor deposited glass films to equilibrium glass films

    Science.gov (United States)

    Flenner, Elijah; Berthier, Ludovic; Charbonneau, Patrick; Zamponi, Francesco

    Vapor deposition of particles onto a substrate held at around 85% of the glass transition temperature can create glasses with increased density, enthalpy, kinetic stability, and mechanical stability compared to an ordinary glass created by cooling. It is estimated that an ordinary glass would need to age thousands of years to reach the kinetic stability of a vapor deposited glass, and a natural question is how close to the equilibrium is the vapor deposited glass. To understand the process, algorithms akin to vapor deposition are used to create simulated glasses that have a higher kinetic stability than their annealed counterpart, although these glasses may not be well equilibrated either. Here we use novel models optimized for a swap Monte Carlo algorithm in order to create equilibrium glass films and compare their properties with those of glasses obtained from vapor deposition algorithms. This approach allows us to directly assess the non-equilibrium nature of vapor-deposited ultrastable glasses. Simons Collaboration on Cracking the Glass Problem and NSF Grant No. DMR 1608086.

  16. Long-term stability of morphine hydrochloride in 0.9% NaCl infusion polyolefin bags after freeze-thaw treatment and in polypropylene syringes at 5 degrees C + 3 degrees C.

    Science.gov (United States)

    Hecq, J-D; Godet, M; Gillet, P; Jamart, J; Galanti, L

    2014-01-01

    The aim of this study was to investigate the long-term stability of morphine hydrochloride in 0.9% NaCI infusion polyolefin bags and polypropylene syringes after storage at 5 degrees C + 3 degrees C and to evaluate the influence of initial freezing and microwave thawing on this stability. Ten polyolefin bags and five polypropylene syringes containing 100 mL of 1 mg/mL of morphine hydrochloride solution in 0.9% NaCI were prepared under aseptic conditions. Five polyolefin bags were frozen at -20 degrees C for 90 days before storage. Immediately after the preparation and after thawing, 2 mL of each bag were withdrawn for the initial concentration measurements. All polyolefin bags and polypropylene syringes were then refrigerated at 5 degrees C + 3 degrees C for 58 days during which the morphine concentrations were measured periodically by high-performance liquid chromatography using a reversed-phase column, naloxone as internal standard, a mobile phase consisting of 5% acetonitrile and 95% of KH2PO4 buffer (pH 3.50), and detection with diode array detector at 254 nm. Visual and microscopic observations and spectrophotometric and pH measurements were also performed. Solutions were considered stable if the concentration remained superior to 90% of the initial concentration. The degradation products peaks were not quantitatively significant and were resolved from the native drug. Polyolefin bag and polypropylene syringe solutions were stable when stored at 5 degrees C + 3 degrees C during these 58 days. No color change or precipitation in the solutions was observed. The physical stability was confirmed by visual, microscopic, and spectrophotometric inspection. There was no significant change in pH during storage. Freezing and microwave thawing didn't influence the infusion stability. Morphine hydrochloride infusions may be prepared in advance by centralized intravenous additive service, frozen in polyolefin bags, and microwave thawed before storage under refrigeration

  17. Filter assembly for metallic and intermetallic tube filters

    Science.gov (United States)

    Alvin, Mary Anne; Lippert, Thomas E.; Bruck, Gerald J.; Smeltzer, Eugene E.

    2001-01-01

    A filter assembly (60) for holding a filter element (28) within a hot gas cleanup system pressure vessel is provided, containing: a filter housing (62), said filter housing having a certain axial length and having a peripheral sidewall, said sidewall defining an interior chamber (66); a one piece, all metal, fail-safe/regenerator device (68) within the interior chamber (66) of the filter housing (62) and/or extending beyond the axial length of the filter housing, said device containing an outward extending radial flange (71) within the filter housing for seating an essential seal (70), the device also having heat transfer media (72) disposed inside and screens (80) for particulate removal; one compliant gasket (70) positioned next to and above the outward extending radial flange of the fail-safe/regenerator device; and a porous metallic corrosion resistant superalloy type filter element body welded at the bottom of the metal fail-safe/regenerator device.

  18. Statistically-Efficient Filtering in Impulsive Environments: Weighted Myriad Filters

    Directory of Open Access Journals (Sweden)

    Juan G. Gonzalez

    2002-01-01

    Full Text Available Linear filtering theory has been largely motivated by the characteristics of Gaussian signals. In the same manner, the proposed Myriad Filtering methods are motivated by the need for a flexible filter class with high statistical efficiency in non-Gaussian impulsive environments that can appear in practice. Myriad filters have a solid theoretical basis, are inherently more powerful than median filters, and are very general, subsuming traditional linear FIR filters. The foundation of the proposed filtering algorithms lies in the definition of the myriad as a tunable estimator of location derived from the theory of robust statistics. We prove several fundamental properties of this estimator and show its optimality in practical impulsive models such as the α-stable and generalized-t. We then extend the myriad estimation framework to allow the use of weights. In the same way as linear FIR filters become a powerful generalization of the mean filter, filters based on running myriads reach all of their potential when a weighting scheme is utilized. We derive the “normal” equations for the optimal myriad filter, and introduce a suboptimal methodology for filter tuning and design. The strong potential of myriad filtering and estimation in impulsive environments is illustrated with several examples.

  19. Filter material charging apparatus for filter assembly for radioactive contaminants

    International Nuclear Information System (INIS)

    Goldsmith, J.M.; O'Nan, A. Jr.

    1977-01-01

    A filter charging apparatus for a filter assembly is described. The filter assembly includes a housing with at least one filter bed therein and the filter charging apparatus for adding filter material to the filter assembly includes a tank with an opening therein, the tank opening being disposed in flow communication with opposed first and second conduit means, the first conduit means being in flow communication with the filter assembly housing and the second conduit means being in flow communication with a blower means. Upon activation of the blower means, the blower means pneumatically conveys the filter material from the tank to the filter housing

  20. Experimental investigations of optical nonlinearities in semiconductor-doped glass waveguides

    International Nuclear Information System (INIS)

    Dannberg, P.; Possner, T.; Braeuer, A.; Bartuch, U.

    1988-01-01

    Both, thermal and electronic optical nonlinearities are studied in semiconductor-doped glass (SDG) waveguides which are fabricated in commercially available sharp-cut filters by Cs + -K + ion exchange. The relaxation time in photodarkened substrates is measured to be 30 ps. By means of a prism coupling set-up the saturation value of the nonlinear index change is determined. Furthermore, a high stability dual-beam interferometer is presented for the measurement of both, thermal and electronic nonlinear refractive index n 2 in planar waveguides. Conclusions about the application of SDG to opto-optical switching are given. (author)

  1. Assessing the role of syringe dispensing machines and mobile van outlets in reaching hard-to-reach and high-risk groups of injecting drug users (IDUs: a review

    Directory of Open Access Journals (Sweden)

    Islam Md Mofizul

    2007-10-01

    Full Text Available Abstract Reaching hard-to-reach and high-risk injecting drug users (IDUs is one of the most important challenges for contemporary needle syringe programs (NSPs. The aim of this review is to examine, based upon the available international experience, the effectiveness of syringe vending machines and mobile van/bus based NSPs in making services more accessible to these hard-to-reach and high-risk groups of IDUs. A literature search revealed 40 papers/reports, of which 18 were on dispensing machines (including vending and exchange machines and 22 on mobile vans. The findings demonstrate that syringe dispensing machines and mobile vans are promising modalities of NSPs, which can make services more accessible to the target group and in particular to the harder-to-reach and higher-risk groups of IDUs. Their anonymous and confidential approaches make services attractive, accessible and acceptable to these groups. These two outlets were found to be complementary to each other and to other modes of NSPs. Services through dispensing machines and mobile vans in strategically important sites are crucial elements in continuing efforts in reducing the spread of HIV and other blood borne viruses among IDUs.

  2. Diopside-Fluorapatite-Wollastonite Based Bioactive Glasses and Glass-ceramics =

    Science.gov (United States)

    Kansal, Ishu

    Bioactive glasses and glass-ceramics are a class of biomaterials which elicit special response on their surface when in contact with biological fluids, leading to strong bonding to living tissue. This particular trait along with good sintering ability and high mechanical strength make them ideal materials for scaffold fabrication. The work presented in this thesis is directed towards understanding the composition-structure-property relationships in potentially bioactive glasses designed in CaO-MgO-P2O5-SiO2-F system, in some cases with added Na2O. The main emphasis has been on unearthing the influence of glass composition on molecular structure, sintering ability and bioactivity of phosphosilicate glasses. The parent glass compositions have been designed in the primary crystallization field of the pseudo-ternary system of diopside (CaO•MgO•2SiO2) - fluorapatite (9CaO•3P2O5•CaF2) - wollastonite (CaO•SiO2), followed by studying the impact of compositional variations on the structure-property relationships and sintering ability of these glasses. All the glasses investigated in this work have been synthesized via melt-quenching route and have been characterized for their molecular structure, sintering ability, chemical degradation and bioactivity using wide array of experimental tools and techniques. It has been shown that in all investigated glass compositions the silicate network was mainly dominated by Q2 units while phosphate in all the glasses was found to be coordinated in orthophosphate environment. The glass compositions designed in alkali-free region of diopside - fluorapatite system demonstrated excellent sintering ability and good bioactivity in order to qualify them as potential materials for scaffold fabrication while alkali-rich bioactive glasses not only hinder the densification during sintering but also induce cytotoxicity in vitro, thus, are not ideal candidates for in vitro tissue engineering. One of our bioglass compositions with low sodium

  3. Particle Characterization for a Protein Drug Product Stored in Pre-Filled Syringes Using Micro-Flow Imaging, Archimedes, and Quartz Crystal Microbalance with Dissipation.

    Science.gov (United States)

    Zheng, Songyan; Puri, Aastha; Li, Jinjiang; Jaiswal, Archana; Adams, Monica

    2017-01-01

    Micro-flow imaging (MFI) has been used for formulation development for analyzing sub-visible particles. Archimedes, a novel technique for analyzing sub-micron particles, has been considered as an orthogonal method to currently existing techniques. This study utilized these two techniques to investigate the effectiveness of polysorbate (PS-80) in mitigating the particle formation of a therapeutic protein formulation stored in silicone oil-coated pre-filled syringes. The results indicated that PS-80 prevented the formation of both protein and silicone oil particles. In the case of protein particles, PS-80 might involve in the interactions with the hydrophobic patches of protein, air bubbles, and the stressed surfaces of silicone oil-coated pre-filled syringes. Such interactions played a role in mitigating the formation of protein particles. Subsequently, quartz crystal microbalance with dissipation (QCM-D) was utilized to characterize the interactions associated with silicone oil, protein, and PS-80 in the solutions. Based on QCM-D results, we proposed that PS-80 likely formed a layer on the interior surfaces of syringes. As a result, the adsorbed PS-80 might block the leakage of silicone oil from the surfaces to solution so that the silicone oil particles were mitigated at the presence of PS-80. Overall, this study demonstrated the necessary of utilizing these three techniques cooperatively in order to better understand the interfacial role of PS-80 in mitigating the formation of protein and silicone oil particles.

  4. A glass capillary based microfluidic electromembrane extraction of basic degradation products of nitrogen mustard and VX from water.

    Science.gov (United States)

    Tak, Vijay; Kabra, Ankur; Pardasani, Deepak; Goud, D Raghavender; Jain, Rajeev; Dubey, D K

    2015-12-24

    In this work, a glass capillary based microfluidic electromembrane extraction (μ-EME) was demonstrated for the first time. The device was made by connecting an auxillary borosilicate glass tubing (O.D. 3mm, I.D. 2mm) perpendicular to main borosilicate glass capillary just below one end of the capillary (O.D. 8mm, I.D. 1.2mm). It generated the distorted T-shaped device with inlet '1' and inlet '2' for the introduction of sample and acceptor solutions, respectively. At one end of this device (inlet '2'), a microsyringe containing acceptor solution along with hollow fiber (O.D. 1000μm) was introduced. This configuration creates the micro-channel between inner wall of glass capillary and outer surface of hollow fiber. Sample solution was pumped into the system through another end of glass capillary (inlet '1'), with a micro-syringe pump. The sample was in direct contact with the supported liquid membrane (SLM), consisted of 20% (w/w) di-(2-ethylhexyl)phosphate in 2-nitrophenyl octyl ether immobilized in the pores of the hollow fiber. In the lumen of the hollow fiber, the acceptor phase was present. The driving force for extraction was direct current (DC) electrical potential sustained over the SLM. Highly polar (logP=-2.5 to 1.4) basic degradation products of nitrogen mustard and VX were selected as model analytes. The influence of chemical composition of SLM, extraction time, voltage and pH of donor and acceptor phase were investigated. The model analytes were extracted from 10μL of pure water with recoveries ranging from 15.7 to 99.7% just after 3min of operation time. Under optimized conditions, good limits of detection (2-50ngmL(-1)), linearity (from 5-1000 to 100-1000ngmL(-1)), and repeatability (RSDs below 11.9%, n=3) were achieved. Applicability of the proposed μ-EME was proved by recovering triethanolamine (31.3%) from 10μL of five times diluted original water sample provided by the Organization for the Prohibition of Chemical Weapons during 28th official

  5. Leaching of glass

    International Nuclear Information System (INIS)

    Hench, L.L.

    1977-01-01

    Understanding surface compositional profiles of glasses over a range of 0-2000 A with a variety of analytical instruments shows that five general types of glass surfaces exist. The surface character of a glass article depends upon bulk composition and environmental history during which surface dealkalization, film formation, and network dissolution can occur. Environmental-surface interactions generally result in complex compositional profiles of all the constituents in a glass. Durable glasses almost always develop a stable surface film which has a higher concentration of network formers than the bulk composition. Compositional effects that are used to improve glass durability usually improve the stability of the surface films. Durability tests or service conditions that lead to film destruction are especially severe for the most silicate glasses. 43 references

  6. Effect of alkaline earth modifier on the optical and structural properties of Cu2+ doped phosphate glasses as a bandpass filter

    Science.gov (United States)

    Farouk, M.; Samir, A.; El Okr, M.

    2018-02-01

    Glasses of composition [16RO-3Al2O3sbnd 6CuOsbnd 20Na2Osbnd 55P2O5], where R is the alkaline earth (R = Mg, Ca, Sr and Ba mol. %), were prepared by conventional melt quenching technique. The glass samples were characterized by X-ray diffraction, infrared spectroscopy, and spectrophotometer. XRD patterns show no sharp peaks indicating the non-crystalline nature of the prepared glasses. The density and molar volume of the glass systems were determined in order to study their structures. These results revealed that addition of alkaline earth elements leads to the formation of non-bridging oxygens (NBOs) and expands (opens up) the structure. The infrared spectra were analyzed to quantify the present phosphate groups. The optical absorption spectra of Cu2+ ions show the characteristic broadband single of Cu2+ ions in octahedral symmetry. The band gap was estimated following two methodologies. The first method considers the band edge of the transmission, while the second approach relays on the estimated values of the optical constants. A decent agreement for the band gap values using the two methods was obtained.

  7. Colloidal glasses

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Colloidal glasses. Glassy state is attained when system fails to reach equilibrium due to crowding of constituent particles. In molecular glasses, glassy state is reached by rapidly lowering the temperature. In colloidal glasses, glassy state is reached by increasing the ...

  8. Determination of Human-Health Pharmaceuticals in Filtered Water by Chemically Modified Styrene-Divinylbenzene Resin-Based Solid-Phase Extraction and High-Performance Liquid Chromatography/Mass Spectrometry

    Science.gov (United States)

    Furlong, Edward T.; Werner, Stephen L.; Anderson, Bruce D.; Cahill, Jeffery D.

    2008-01-01

    In 1999, the Methods Research and Development Program of the U.S. Geological Survey National Water Quality Laboratory began the process of developing a method designed to identify and quantify human-health pharmaceuticals in four filtered water-sample types: reagent water, ground water, surface water minimally affected by human contributions, and surface water that contains a substantial fraction of treated wastewater. Compounds derived from human pharmaceutical and personal-care product use, which enter the environment through wastewater discharge, are a newly emerging area of concern; this method was intended to fulfill the need for a highly sensitive and highly selective means to identify and quantify 14 commonly used human pharmaceuticals in filtered-water samples. The concentrations of 12 pharmaceuticals are reported without qualification; the concentrations of two pharmaceuticals are reported as estimates because long-term reagent-spike sample recoveries fall below acceptance criteria for reporting concentrations without qualification. The method uses a chemically modified styrene-divinylbenzene resin-based solid-phase extraction (SPE) cartridge for analyte isolation and concentration. For analyte detection and quantitation, an instrumental method was developed that used a high-performance liquid chromatography/mass spectrometry (HPLC/MS) system to separate the pharmaceuticals of interest from each other and coextracted material. Immediately following separation, the pharmaceuticals are ionized by electrospray ionization operated in the positive mode, and the positive ions produced are detected, identified, and quantified using a quadrupole mass spectrometer. In this method, 1-liter water samples are first filtered, either in the field or in the laboratory, using a 0.7-micrometer (um) nominal pore size glass-fiber filter to remove suspended solids. The filtered samples then are passed through cleaned and conditioned SPE cartridges at a rate of about 15

  9. Heating-induced glass-glass and glass-liquid transformations in computer simulations of water

    Science.gov (United States)

    Chiu, Janet; Starr, Francis W.; Giovambattista, Nicolas

    2014-03-01

    Water exists in at least two families of glassy states, broadly categorized as the low-density (LDA) and high-density amorphous ice (HDA). Remarkably, LDA and HDA can be reversibly interconverted via appropriate thermodynamic paths, such as isothermal compression and isobaric heating, exhibiting first-order-like phase transitions. We perform out-of-equilibrium molecular dynamics simulations of glassy water using the ST2 model to study the evolution of LDA and HDA upon isobaric heating. Depending on pressure, glass-to-glass, glass-to-crystal, glass-to-vapor, as well as glass-to-liquid transformations are found. Specifically, heating LDA results in the following transformations, with increasing heating pressures: (i) LDA-to-vapor (sublimation), (ii) LDA-to-liquid (glass transition), (iii) LDA-to-HDA-to-liquid, (iv) LDA-to-HDA-to-liquid-to-crystal, and (v) LDA-to-HDA-to-crystal. Similarly, heating HDA results in the following transformations, with decreasing heating pressures: (a) HDA-to-crystal, (b) HDA-to-liquid-to-crystal, (c) HDA-to-liquid (glass transition), (d) HDA-to-LDA-to-liquid, and (e) HDA-to-LDA-to-vapor. A more complex sequence may be possible using lower heating rates. For each of these transformations, we determine the corresponding transformation temperature as function of pressure, and provide a P-T "phase diagram" for glassy water based on isobaric heating. Our results for isobaric heating dovetail with the LDA-HDA transformations reported for ST2 glassy water based on isothermal compression/decompression processes [Chiu et al., J. Chem. Phys. 139, 184504 (2013)]. The resulting phase diagram is consistent with the liquid-liquid phase transition hypothesis. At the same time, the glass phase diagram is sensitive to sample preparation, such as heating or compression rates. Interestingly, at least for the rates explored, our results suggest that the LDA-to-liquid (HDA-to-liquid) and LDA-to-HDA (HDA-to-LDA) transformation lines on heating are related

  10. Heating-induced glass-glass and glass-liquid transformations in computer simulations of water

    International Nuclear Information System (INIS)

    Chiu, Janet; Giovambattista, Nicolas; Starr, Francis W.

    2014-01-01

    Water exists in at least two families of glassy states, broadly categorized as the low-density (LDA) and high-density amorphous ice (HDA). Remarkably, LDA and HDA can be reversibly interconverted via appropriate thermodynamic paths, such as isothermal compression and isobaric heating, exhibiting first-order-like phase transitions. We perform out-of-equilibrium molecular dynamics simulations of glassy water using the ST2 model to study the evolution of LDA and HDA upon isobaric heating. Depending on pressure, glass-to-glass, glass-to-crystal, glass-to-vapor, as well as glass-to-liquid transformations are found. Specifically, heating LDA results in the following transformations, with increasing heating pressures: (i) LDA-to-vapor (sublimation), (ii) LDA-to-liquid (glass transition), (iii) LDA-to-HDA-to-liquid, (iv) LDA-to-HDA-to-liquid-to-crystal, and (v) LDA-to-HDA-to-crystal. Similarly, heating HDA results in the following transformations, with decreasing heating pressures: (a) HDA-to-crystal, (b) HDA-to-liquid-to-crystal, (c) HDA-to-liquid (glass transition), (d) HDA-to-LDA-to-liquid, and (e) HDA-to-LDA-to-vapor. A more complex sequence may be possible using lower heating rates. For each of these transformations, we determine the corresponding transformation temperature as function of pressure, and provide a P-T “phase diagram” for glassy water based on isobaric heating. Our results for isobaric heating dovetail with the LDA-HDA transformations reported for ST2 glassy water based on isothermal compression/decompression processes [Chiu et al., J. Chem. Phys. 139, 184504 (2013)]. The resulting phase diagram is consistent with the liquid-liquid phase transition hypothesis. At the same time, the glass phase diagram is sensitive to sample preparation, such as heating or compression rates. Interestingly, at least for the rates explored, our results suggest that the LDA-to-liquid (HDA-to-liquid) and LDA-to-HDA (HDA-to-LDA) transformation lines on heating are related

  11. Heating-induced glass-glass and glass-liquid transformations in computer simulations of water

    Energy Technology Data Exchange (ETDEWEB)

    Chiu, Janet; Giovambattista, Nicolas [Department of Physics, Brooklyn College of the City University of New York, Brooklyn, New York 11210 (United States); Starr, Francis W. [Department of Physics, Wesleyan University, Middletown, Connecticut 06459 (United States)

    2014-03-21

    Water exists in at least two families of glassy states, broadly categorized as the low-density (LDA) and high-density amorphous ice (HDA). Remarkably, LDA and HDA can be reversibly interconverted via appropriate thermodynamic paths, such as isothermal compression and isobaric heating, exhibiting first-order-like phase transitions. We perform out-of-equilibrium molecular dynamics simulations of glassy water using the ST2 model to study the evolution of LDA and HDA upon isobaric heating. Depending on pressure, glass-to-glass, glass-to-crystal, glass-to-vapor, as well as glass-to-liquid transformations are found. Specifically, heating LDA results in the following transformations, with increasing heating pressures: (i) LDA-to-vapor (sublimation), (ii) LDA-to-liquid (glass transition), (iii) LDA-to-HDA-to-liquid, (iv) LDA-to-HDA-to-liquid-to-crystal, and (v) LDA-to-HDA-to-crystal. Similarly, heating HDA results in the following transformations, with decreasing heating pressures: (a) HDA-to-crystal, (b) HDA-to-liquid-to-crystal, (c) HDA-to-liquid (glass transition), (d) HDA-to-LDA-to-liquid, and (e) HDA-to-LDA-to-vapor. A more complex sequence may be possible using lower heating rates. For each of these transformations, we determine the corresponding transformation temperature as function of pressure, and provide a P-T “phase diagram” for glassy water based on isobaric heating. Our results for isobaric heating dovetail with the LDA-HDA transformations reported for ST2 glassy water based on isothermal compression/decompression processes [Chiu et al., J. Chem. Phys. 139, 184504 (2013)]. The resulting phase diagram is consistent with the liquid-liquid phase transition hypothesis. At the same time, the glass phase diagram is sensitive to sample preparation, such as heating or compression rates. Interestingly, at least for the rates explored, our results suggest that the LDA-to-liquid (HDA-to-liquid) and LDA-to-HDA (HDA-to-LDA) transformation lines on heating are related

  12. Database and Interim Glass Property Models for Hanford HLW Glasses

    International Nuclear Information System (INIS)

    Hrma, Pavel R; Piepel, Gregory F; Vienna, John D; Cooley, Scott K; Kim, Dong-Sang; Russell, Renee L

    2001-01-01

    The purpose of this report is to provide a methodology for an increase in the efficiency and a decrease in the cost of vitrifying high-level waste (HLW) by optimizing HLW glass formulation. This methodology consists in collecting and generating a database of glass properties that determine HLW glass processability and acceptability and relating these properties to glass composition. The report explains how the property-composition models are developed, fitted to data, used for glass formulation optimization, and continuously updated in response to changes in HLW composition estimates and changes in glass processing technology. Further, the report reviews the glass property-composition literature data and presents their preliminary critical evaluation and screening. Finally the report provides interim property-composition models for melt viscosity, for liquidus temperature (with spinel and zircon primary crystalline phases), and for the product consistency test normalized releases of B, Na, and Li. Models were fitted to a subset of the screened database deemed most relevant for the current HLW composition region

  13. Safe and unsafe spaces: Non-fatal overdose, arrest, and receptive syringe sharing among people who inject drugs in public and semi-public spaces in Baltimore City.

    Science.gov (United States)

    Hunter, Kyle; Park, Ju Nyeong; Allen, Sean T; Chaulk, Patrick; Frost, Taeko; Weir, Brian W; Sherman, Susan G

    2018-04-13

    The spaces in which drug use occurs constitutes a key aspect of the "risk environment" of people who inject drugs (PWID). We aimed to add nuance to the characterization of "safe" and "unsafe" spaces in PWID's environments to further understand how these spaces amplify the risk of morbidities associated with injection drug use. PWID were recruited through the Baltimore City syringe service program and through peer referral. Participants completed a socio-behavioral survey. Multivariable logistic regression was used to identify associations between utilization of public, semi-public and private spaces with arrest, non-fatal overdose, and receptive syringe sharing. The sample of PWID (N = 283) was mostly 45 years and older (54%), male (69%), Black (55%), and heroin users (96%). Compared to PWID who primarily used private settings, the adjusted odds of recent overdose were greater among PWID who mostly used semi-public and public locations to inject drugs. We also found independent associations between arrest and semi-public spaces, and between receptive syringe sharing and public spaces (all p spaces where PWID can reduce their risk of overdose, likelihood of arrest and blood-borne diseases, and the dual potential of the environment in promoting health and risk. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Anterior and middle superior alveolar nerve block for anesthesia of maxillary teeth using conventional syringe

    Directory of Open Access Journals (Sweden)

    Ignacio Velasco

    2012-01-01

    Full Text Available Background: Dental procedures in the maxilla typically require multiple injections and may inadvertently anesthetize facial structures and affect the smile line. To minimize these inconveniences and reduce the number of total injections, a relatively new injection technique has been proposed for maxillary procedures, the anterior and middle superior alveolar (AMSA nerve block, which achieves pulpal anesthesia from the central incisor to second premolar through palatal approach with a single injection. The purpose of this article is to provide background information on the anterior and middle superior alveolar nerve block and demonstrate its success rates of pulpal anesthesia using the conventional syringe. Materials and Methods: Thirty Caucasian patients (16 men and 14 women with an average age of 22 years-old, belonging to the School of Dentistry of Los Andes University, were selected. All the patients received an AMSA nerve block on one side of the maxilla using the conventional syringe, 1 ml of lidocaine 2% with epinephrine 1:100.000 was injected to all the patients. Results: The AMSA nerve block obtained a 66% anesthetic success in the second premolar, 40% in the first premolar, 60% in the canine, 23.3% in the lateral incisor, and 16.7% in the central incisor. Conclusions: Because of the unpredictable anesthetic success of the experimental teeth and variable anesthesia duration, the technique is disadvantageous for clinical application as the first choice, counting with other techniques that have greater efficacy in the maxilla. Although, anesthetizing the teeth without numbing the facial muscles may be useful in restorative dentistry.

  15. Neutron- and light-scattering studies of the liquid-to-glass and glass-to-glass transitions in dense copolymer micellar solutions

    International Nuclear Information System (INIS)

    Chen Weiren; Chen Sowhsin; Mallamace, Francesco; Glinka, Charles J.; Fratini, Emiliano

    2003-01-01

    Recent mode coupling theory (MCT) calculations show that if a short-range attractive interaction is added to the pure hard sphere system, one may observe a new type of glass originating from the clustering effect (the attractive glass) as a result of the attractive interaction. This is in addition to the known glass-forming mechanism due to the cage effect in the hard sphere system (the repulsive glass). The calculations also indicate that if the range of attraction is sufficiently short compared to the diameter of the particle, within a certain interval of volume fractions where the two glass-forming mechanisms nearly balance each other, varying the external control parameter, the effective temperature, makes the glass-to-liquid-to-glass reentrance and the glass-to-glass transitions possible. Here we present experimental evidence of both transitions, obtained from small-angle neutron-scattering and photon correlation measurements taken from dense L64 copolymer micellar solutions in heavy water. Varying the temperature in certain predicted volume fraction range triggers a sharp transition between these two different types of glass. In particular, according to MCT, there is an end point (called A 3 singularity) of this glass-to-glass transition line, beyond which the long-time dynamics of the two glasses become identical. Our findings confirm this theoretical prediction. Surprisingly, although the Debye-Waller factors, the long-time limit of the coherent intermediate scattering functions, of these two glasses obtained from photon correlation measurements indeed become identical at the predicted volume fraction, they exhibit distinctly different intermediate time relaxation. Furthermore, our experimental results obtained from volume fractions beyond the end point are characterized by the same features as the repulsive glass obtained before the end point. A complete phase diagram giving the boundaries of the structural arrest transitions for L64 micellar system is

  16. Low phonon energies and wideband optical windows of La2O3-Ga2O3 glasses prepared using an aerodynamic levitation technique.

    Science.gov (United States)

    Yoshimoto, Kohei; Masuno, Atsunobu; Ueda, Motoi; Inoue, Hiroyuki; Yamamoto, Hiroshi; Kawashima, Tastunori

    2017-03-30

    xLa 2 O 3 -(100 - x)Ga 2 O 3 binary glasses were synthesized by an aerodynamic levitation technique. The glass-forming region was found to be 20 ≤ x ≤ 57. The refractive indices were greater than 1.92 and increased linearly with increasing x. The polarizabilities of oxide ions were estimated to be 2.16-2.41 Å 3 , indicating that the glasses were highly ionic. The glasses were transparent over a very wide range from the ultraviolet to the mid-infrared region. The widest transparent window among the oxide glasses was from 270 nm to 10 μm at x = 55. From the Raman scattering spectra, a decrease in bridging oxide ions and an increase in non-bridging oxide ions were confirmed to occur with increasing La 2 O 3 content. The maximum phonon energy was found to be approximately 650 cm -1 , being one of the lowest among oxide glasses. These results show that La 2 O 3 -Ga 2 O 3 binary glasses should be promising host materials for optical applications such as lenses, windows, and filters over a very wide wavelength range.

  17. Low phonon energies and wideband optical windows of La2O3-Ga2O3 glasses prepared using an aerodynamic levitation technique

    Science.gov (United States)

    Yoshimoto, Kohei; Masuno, Atsunobu; Ueda, Motoi; Inoue, Hiroyuki; Yamamoto, Hiroshi; Kawashima, Tastunori

    2017-03-01

    xLa2O3-(100 - x)Ga2O3 binary glasses were synthesized by an aerodynamic levitation technique. The glass-forming region was found to be 20 ≤ x ≤ 57. The refractive indices were greater than 1.92 and increased linearly with increasing x. The polarizabilities of oxide ions were estimated to be 2.16-2.41 Å3, indicating that the glasses were highly ionic. The glasses were transparent over a very wide range from the ultraviolet to the mid-infrared region. The widest transparent window among the oxide glasses was from 270 nm to 10 μm at x = 55. From the Raman scattering spectra, a decrease in bridging oxide ions and an increase in non-bridging oxide ions were confirmed to occur with increasing La2O3 content. The maximum phonon energy was found to be approximately 650 cm-1, being one of the lowest among oxide glasses. These results show that La2O3-Ga2O3 binary glasses should be promising host materials for optical applications such as lenses, windows, and filters over a very wide wavelength range.

  18. Aqueous corrosion of silicate glasses. Analogy between volcanic glasses and the French nuclear waste glass R7T7

    International Nuclear Information System (INIS)

    Goldschmidt, F.

    1991-01-01

    The behaviour of borosilicate glasses upon aqueous corrosion is controlled for long periods of time (>10,000 years) by processes which are not directly accessible by means of laboratory experiments. The analogical approach consists here to compare leaching performances between the french nuclear waste glass R7T7 and natural volcanic glasses, basaltic and rhyolitic ones. The three glasses were leached in the same conditions; open system, 90 deg C, initial pH of 9.7. Basaltic and R7T7 glasses having the same kinetic of dissolution, the basaltic glass was chosen as the best analogue. (author). refs., figs., tabs

  19. Microbiological Contamination of Drugs during Their Administration for Anesthesia in the Operating Room.

    Science.gov (United States)

    Gargiulo, Derryn A; Mitchell, Simon J; Sheridan, Janie; Short, Timothy G; Swift, Simon; Torrie, Jane; Webster, Craig S; Merry, Alan F

    2016-04-01

    The aseptic techniques of anesthesiologists in the preparation and administration of injected medications have not been extensively investigated, but emerging data demonstrate that inadvertent lapses in aseptic technique may be an important contributor to surgical site and other postoperative infections. A prospective, open, microbiological audit of 303 cases in which anesthesiologists were asked to inject all bolus drugs, except propofol and antibiotics, through a 0.2-µm filter was performed. The authors cultured microorganisms, if present, from the 0.2-µm filter unit and from the residual contents of the syringes used for drawing up or administering drugs. Participating anesthesiologists rated ease of use of the filters after each case. Twenty-three anesthesiologists each anesthetized up to 25 adult patients. The authors isolated microorganisms from filter units in 19 (6.3%) of 300 cases (3 cases were excluded), including Staphylococcus capitis, Staphylococcus warneri, Staphylococcus epidermidis, Staphylococcus haemolyticus, Micrococcus luteus/lylae, Corynebacterium, and Bacillus species. The authors collected used syringes at the end of each case and grew microorganisms from residual drug in 55 of these 2,318 (2.4%) syringes including all the aforementioned microorganisms and also Kocuria kristinae, Staphylococcus aureus, and Staphylococcus hominus. Participants' average rating of ease of use of the filter units was 3.5 out of 10 (0 being very easy and 10 being very difficult). Microorganisms with the potential to cause infection are being injected (presumably inadvertently) into some patients during the administration of intravenous drugs by bolus during anesthesia. The relevance of this finding to postoperative infections warrants further investigation.

  20. Effect of liposomes on rheological and syringeability properties of hyaluronic acid hydrogels intended for local injection of drugs.

    Science.gov (United States)

    El Kechai, Naila; Bochot, Amélie; Huang, Nicolas; Nguyen, Yann; Ferrary, Evelyne; Agnely, Florence

    2015-06-20

    The aim of this work was to thoroughly study the effect of liposomes on the rheological and the syringeability properties of hyaluronic acid (HA) hydrogels intended for the local administration of drugs by injection. Whatever the characteristics of the liposomes added (neutral, positively or negatively charged, with a corona of polyethylene glycol chains, size), the viscosity and the elasticity of HA gels increased in a lipid concentration-dependent manner. Indeed, liposomes strengthened the network formed by HA chains due to their interactions with this polymer. The nature and the resulting effects of these interactions depended on liposome composition and concentration. The highest viscosity and elasticity were observed with liposomes covered by polyethylene glycol chains while neutral liposomes displayed the lowest effect. Despite their high viscosity at rest, all the formulations remained easily injectable through needles commonly used for local injections thanks to the shear-thinning behavior of HA gels. The present study demonstrates that rheological and syringeability tests are both necessary to elucidate the behavior of such systems during and post injection. In conclusion, HA liposomal gels appear to be a promising and versatile formulation platform for a wide range of applications in local drug delivery when an injection is required. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Spheroidization of glass powders for glass ionomer cements.

    Science.gov (United States)

    Gu, Y W; Yap, A U J; Cheang, P; Kumar, R

    2004-08-01

    Commercial angular glass powders were spheroidized using both the flame spraying and inductively coupled radio frequency plasma spraying techniques. Spherical powders with different particle size distributions were obtained after spheroidization. The effects of spherical glass powders on the mechanical properties of glass ionomer cements (GICs) were investigated. Results showed that the particle size distribution of the glass powders had a significant influence on the mechanical properties of GICs. Powders with a bimodal particle size distribution ensured a high packing density of glass ionomer cements, giving relatively high mechanical properties of GICs. GICs prepared by flame-spheroidized powders showed low strength values due to the loss of fine particles during flame spraying, leading to a low packing density and few metal ions reacting with polyacrylic acid to form cross-linking. GICs prepared by the nano-sized powders showed low strength because of the low bulk density of the nano-sized powders and hence low powder/liquid ratio of GICs.

  2. Cost and waste volume reduction in HEPA filter trains by effective pre-filtration

    International Nuclear Information System (INIS)

    Chadwick, Chris

    2007-01-01

    Data published elsewhere (Moore, et al., 1992; Bergman et al., 1997) suggests that the then costs of disposable type Glass Fibre HEPA filtration trains to the DOE was $55 million per year (based on an average usage of HEPA panels of 11,748 pieces per year between 1987 and 1990), $50 million of which was attributable to installation, testing, removal and disposal. The same authors suggest that by 1995 the number of HEPA panels being used had dropped to an estimated 4000 pieces per year due to the ending of the Cold War. The yearly cost to the DOE of 4000 units per year was estimated to be $29.5 million using the same parameters that previously suggested the $55 million figure. Within that cost estimate, $300 each was the value given to the filter and $4,450 was given to peripheral activity per filter. Clearly, if the $4,450 component could be reduced, tremendous saving could result, in addition to a significant reduction in the legacy burden of waste volumes. This same cost is applied to both the 11,748 and 4000 usage figures. The work up to now has focussed on the development of a low cost, long life (cleanable), direct replacement of the traditional filter train. This paper will review an alternative strategy, that of preventing the contaminating dust from reaching and blinding the HEPA filters, and thereby removing the need to replace them. What has become clear is that 'low cost' and 'Metallic HEPA' are not compatible terms. The original Bergman et al., 1997 work suggested that 1000 cfm (cubic feet per minute) (1690 m 3 /hr) stainless HEPAs could be commercially available for $5000 each after development (although the $70,000 development unit may be somewhat exaggerated - the authors own company have estimated development units able to be retrofitted into strengthened standard housings would be available for perhaps $30,000). The likely true cost of such an item produced industrially in significant numbers may be closer to $15,000 each. That being the case, the

  3. Volatility and leachability of heavy metals and radionuclides in thermally treated HEPA filter media generated from nuclear facilities.

    Science.gov (United States)

    Yoon, In-Ho; Choi, Wang-Kyu; Lee, Suk-Chol; Min, Byung-Youn; Yang, Hee-Chul; Lee, Kune-Woo

    2012-06-15

    The purpose of the present study was to apply thermal treatments to reduce the volume of HEPA filter media and to investigate the volatility and leachability of heavy metals and radionuclides during thermal treatment. HEPA filter media were transformed to glassy bulk material by thermal treatment at 900°C for 2h. The most abundant heavy metal in the HEPA filter media was Zn, followed by Sr, Pb and Cr, and the main radionuclide was Cs-137. The volatility tests showed that the heavy metals and radionuclides in radioactive HEPA filter media were not volatilized during the thermal treatment. PCT tests indicated that the leachability of heavy metals and radionuclides was relatively low compared to those of other glasses. XRD results showed that Zn and Cs reacted with HEPA filter media and were transformed into crystalline willemite (ZnO·SiO(2)) and pollucite (Cs(2)OAl(2)O(3)4SiO(2)), which are not volatile or leachable. The proposed technique for the volume reduction and transformation of radioactive HEPA filter media into glassy bulk material is a simple and energy efficient procedure without additives that can be performed at relatively low temperature compared with conventional vitrification process. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Determination of atmospheric iodine species using a system of specifically prepared filters and IDMS

    International Nuclear Information System (INIS)

    Gaebler, H.E.; Heumann, K.G.

    1993-01-01

    A system was developed which allowed the determination of four different atmospheric iodine species by preparing glass microfibre filters, which were arranged in consecutive order, in a specific way. Particulate iodine was collected by a particle filter, HI and I 2 by a NaOH impregnated filter, HOI was adsorbed on a TBAH impregnated filter and organoiodine was adsorbed on a filter loaded with activated charcoal. These behaviours were checked by extensive model experiments. Two or more filters of the same type were used in series to show the degree of collection of one iodine species. Two European samples, one of continental and one of marine origin, and two Antarctic samples were analysed by this filter system using isotope dilution mass spectrometry (IDMS) for quantification. The distribution pattern for the different iodine species is similar for the two European samples. Organoiodine is found to be the most abundant species whereas in Antarctica the HI/I 2 fraction is up to nearly 50% of the total iodine. The particulate iodine fraction is higher in Europe than in Antarctica, which is due to the low particle concentration in the remote area of Antarctica. The higher HI/I 2 and HOI fractions found at the North Sea compared with the continental sample indicate that the ocean is a primary source of these species. Concentrations in the range of (0.3-3.1) ngI/m 3 were analysed for particulate iodine, (0.4-1.3) ng I/m 3 for HI/I 2 , (0.2-1.8) ng I/m 3 for HOI and (0.4-7.6) ng I/m 3 for organoiodine. The detection limits varied with the variances of the blank values of the different filters and lay between 0.02 ng I/m 3 and 0.24 ng I/m 3 using sample volumes of 70 m 3 air. (orig.)

  5. GLASS COMPOSITION-TCLP RESPONSE MODEL FOR WASTE GLASSES

    International Nuclear Information System (INIS)

    Kim, Dong-Sang; Vienna, John D.

    2004-01-01

    A first-order property model for normalized Toxicity Characteristic Leaching Procedure (TCLP) release as a function of glass composition was developed using data collected from various studies. The normalized boron release is used to estimate the release of toxic elements based on the observation that the boron release represents the conservative release for those constituents of interest. The current TCLP model has two targeted application areas: (1) delisting of waste-glass product as radioactive (not mixed) waste and (2) designating the glass wastes generated from waste-glass research activities as hazardous or non-hazardous. This paper describes the data collection and model development for TCLP releases and discusses the issues related to the application of the model

  6. Multiple Glass Ceilings

    OpenAIRE

    Russo, Giovanni; Hassink, Wolter

    2011-01-01

    Both vertical (between job levels) and horizontal (within job levels) mobility can be sources of wage growth. We find that the glass ceiling operates at both margins. The unexplained part of the wage gap grows across job levels (glass ceiling at the vertical margin) and across the deciles of the intra-job-level wage distribution (glass ceiling at the horizontal margin). This implies that women face many glass ceilings, one for each job level above the second, and that the glass ceiling is a p...

  7. Thermal properties and crystallization of lithium–mica glass and glass-ceramics

    International Nuclear Information System (INIS)

    Nia, A. Faeghi

    2013-01-01

    Highlights: • Two groups of Li–mica glass-ceramics, have been compared. • By controlling the glass composition, crystalline lepidolite was obtained. • The T p of Li–mica was through the previous virgilite and eucryptite phase. - Abstract: The purpose of this study was the synthesis of two groups of Li–mica glass-ceramics denoted by lepidolite (Al 2.5 F 2 KLi 1.5 O 10 Si 3 ) and Li-phlogopite (LiMg 3 AlSi 3 O 10 F 2 ). The studied system was SiO 2 –Al 2 O 3 –MgO–K 2 O–Li 2 O. A total of 3 compositions were prepared. Bulk casted glasses and sintered glass-ceramics of Li-phlogopite and lepidolite systems, were prepared. Eucryptite and virgilite were two prior phases of lepidolite and Li-phlogopite crystallization. It was shown that the obtained glass-ceramics have lower TEC than corresponding glasses. Sinterability of lepidolite glass-ceramic was shown that improved by increasing the Al 2 O 3 content in glass composition. TEC and microhardness values were α = 6.08 × 10 −6 /°C, 755 ± 11.1, α = 7.86 × 10 −6 /°C, 739 ± 7.4 and α = 5.05 × 10 −6 /°C, 658 ± 6.2 HV for Li-lep, Klep1 and Klep2 glasses, respectively

  8. Experimental study of filter cake formation on different filter media

    International Nuclear Information System (INIS)

    Saleem, M.

    2009-01-01

    Removal of particulate matter from gases generated in the process industry is important for product recovery as well as emission control. Dynamics of filtration plant depend on operating conditions. The models, that predict filter plant behaviour, involve empirical resistance parameters which are usually derived from limited experimental data and are characteristics of the filter media and filter cake (dust deposited on filter medium). Filter cake characteristics are affected by the nature of filter media, process parameters and mode of filter regeneration. Removal of dust particles from air is studied in a pilot scale jet pulsed bag filter facility resembling closely to the industrial filters. Limestone dust and ambient air are used in this study with two widely different filter media. All important parameters like pressure drop, gas flow rate, dust settling, are recorded continuously at 1s interval. The data is processed for estimation of the resistance parameters. The pressure drop rise on test filter media is compared. Results reveal that the surface of filter media has an influence on pressure drop rise (concave pressure drop rise). Similar effect is produced by partially jet pulsed filter surface. Filter behaviour is also simulated using estimated parameters and a simplified model and compared with the experimental results. Distribution of cake area load is therefore an important aspect of jet pulse cleaned bag filter modeling. Mean specific cake resistance remains nearly constant on thoroughly jet pulse cleaned membrane coated filter bags. However, the trend can not be confirmed without independent cake height and density measurements. Thus the results reveal the importance of independent measurements of cake resistance. (author)

  9. MST Filterability Tests

    Energy Technology Data Exchange (ETDEWEB)

    Poirier, M. R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Burket, P. R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Duignan, M. R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-03-12

    The Savannah River Site (SRS) is currently treating radioactive liquid waste with the Actinide Removal Process (ARP) and the Modular Caustic Side Solvent Extraction Unit (MCU). The low filter flux through the ARP has limited the rate at which radioactive liquid waste can be treated. Recent filter flux has averaged approximately 5 gallons per minute (gpm). Salt Batch 6 has had a lower processing rate and required frequent filter cleaning. Savannah River Remediation (SRR) has a desire to understand the causes of the low filter flux and to increase ARP/MCU throughput. In addition, at the time the testing started, SRR was assessing the impact of replacing the 0.1 micron filter with a 0.5 micron filter. This report describes testing of MST filterability to investigate the impact of filter pore size and MST particle size on filter flux and testing of filter enhancers to attempt to increase filter flux. The authors constructed a laboratory-scale crossflow filter apparatus with two crossflow filters operating in parallel. One filter was a 0.1 micron Mott sintered SS filter and the other was a 0.5 micron Mott sintered SS filter. The authors also constructed a dead-end filtration apparatus to conduct screening tests with potential filter aids and body feeds, referred to as filter enhancers. The original baseline for ARP was 5.6 M sodium salt solution with a free hydroxide concentration of approximately 1.7 M.3 ARP has been operating with a sodium concentration of approximately 6.4 M and a free hydroxide concentration of approximately 2.5 M. SRNL conducted tests varying the concentration of sodium and free hydroxide to determine whether those changes had a significant effect on filter flux. The feed slurries for the MST filterability tests were composed of simple salts (NaOH, NaNO2, and NaNO3) and MST (0.2 – 4.8 g/L). The feed slurry for the filter enhancer tests contained simulated salt batch 6 supernate, MST, and filter enhancers.

  10. Crystallization In Multicomponent Glasses

    International Nuclear Information System (INIS)

    Kruger, A.A.; Hrma, P.R.

    2009-01-01

    In glass processing situations involving glass crystallization, various crystalline forms nucleate, grow, and dissolve, typically in a nonuniform temperature field of molten glass subjected to convection. Nuclear waste glasses are remarkable examples of multicomponent vitrified mixtures involving partial crystallization. In the glass melter, crystals form and dissolve during batch-to-glass conversion, melter processing, and product cooling. Crystals often agglomerate and sink, and they may settle at the melter bottom. Within the body of cooling glass, multiple phases crystallize in a non-uniform time-dependent temperature field. Self-organizing periodic distribution (the Liesegnang effect) is common. Various crystallization phenomena that occur in glass making are reviewed.

  11. CRYSTALLIZATION IN MULTICOMPONENT GLASSES

    Energy Technology Data Exchange (ETDEWEB)

    KRUGER AA; HRMA PR

    2009-10-08

    In glass processing situations involving glass crystallization, various crystalline forms nucleate, grow, and dissolve, typically in a nonuniform temperature field of molten glass subjected to convection. Nuclear waste glasses are remarkable examples of multicomponent vitrified mixtures involving partial crystallization. In the glass melter, crystals form and dissolve during batch-to-glass conversion, melter processing, and product cooling. Crystals often agglomerate and sink, and they may settle at the melter bottom. Within the body of cooling glass, multiple phases crystallize in a non-uniform time-dependent temperature field. Self-organizing periodic distribution (the Liesegnang effect) is common. Various crystallization phenomena that occur in glass making are reviewed.

  12. Volumetric change of simulated radioactive waste glass irradiated by electron accelerator. [Silica glass

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Seichi; Furuya, Hirotaka; Inagaki, Yaohiro; Kozaka, Tetsuo; Sugisaki, Masayasu

    1987-11-01

    Density changes of simulated radioactive waste glasses, silica glass and Pyrex glass irradiated by an electron accelerator were measured by a ''sink-float'' technique. The density changes of the waste and silica glasses were less than 0.05 %, irradiated at 2.0 MeV up to the fluence of 1.7 x 10/sup 17/ ecm/sup 2/, while were remarkably smaller than that of Pyrex glass of 0.18 % shrinkage. Precision of the measurements in the density changes of the waste glass was lower than that of Pyrex glass possibly because of the inhomogeneity of the waste glass

  13. Contact with hospital syringes containing body fluids: implications for medical waste management regulation Jeringas en contacto con sangre y fluidos corporales utilizadas en el hospital: implicaciones para el manejo de desechos hospitalarios

    Directory of Open Access Journals (Sweden)

    Patricia Volkow

    2003-04-01

    Full Text Available OBJECTIVE: To determine amount of syringes used in the hospital and extent of contact with blood and body fluids of these syringes. MATERIAL AND METHODS: Syringe use was surveyed at a tertiary care center for one week; syringes were classified into the following four categories according to use: a contained blood; b contained other body fluids (urine, gastric secretion, cerebrospinal fluid, wound drainage; c used exclusively for drug dilution and application in plastic intravenous (IV tubes, and d for intramuscular (IM, subcutaneous (SC, or intradermic (ID injections. RESULTS: A total of 7 157 plastic disposable syringes was used; 1 227 (17% contained blood during use, 346 (4.8%, other body fluids, 5 257 (73% were used exclusively for drug dilution and application in plastic IV lines, and 327 (4.5% were utilized for IM, SC, or ID injections. An estimated 369 140 syringes used annually, or eight syringes per patient per in-hospital day. All syringes were disposed of as regulated medical waste, in observance of the law. CONCLUSIONS: There is an urgent need to review recommendations for medical waste management by both international agencies and local governments, based on scientific data and a cost-benefit analysis, to prevent resource waste and further environmental damage.OBJETIVO: Cuantificar el número de jeringas que se utilizan en el hospital y calcular cuántas de éstas entran en contacto con sangre o fluidos corporales. MATERIAL Y MÉTODOS: Se hizo una encuesta del uso de jeringas en un hospital de tercer nivel de atención durante toda una semana. Se clasificaron, de acuerdo con el uso que se les dio, en cuatro categorías: a aspiración de sangre, b otros fluidos corporales (orina, secreción gástrica, líquido cefalorraquídeo, drenaje de herida, etcétera, c uso exclusivo para diluir medicamentos y administrarlos a través de tubos de terapia intravenosa, d para aplicación de inyecciones intramusculares (IM, subcutáneas (SC o

  14. A dense grid of narrow bandpass steep edge filters for the JST/T250 telescope: summary of results

    Science.gov (United States)

    Brauneck, U.; Sprengard, R.; Bourquin, S.; Marín-Franch, A.

    2017-09-01

    On the Javalambre mountain in Spain, the Centro de Estudios de Fisica del Cosmos de Aragon (CEFCA) has setup a new wide field telescope, the JST/T250: a 2.55 m telescope with a plate scale of 22.67"/mm and a 3° diameter field of view. To conduct a photometric sky survey, a large format mosaic camera made of 14 individual CCDs is used in combination with filter trays containing 14 filters each of theses 101.7 x 96.5 mm in size. For this instrument, SCHOTT manufactured 56 specially designed steep edged bandpass interference filters which were recently completed. The filter set consists of bandpass filters in the range between 348,5 nm and 910 nm and a longpass filter at 915 nm. Most of the filters have FWHM of 14.5 nm and a blocking between 250 and 1050 nm with optical density of OD5. Absorptive color glass substrates in combination with interference filters were used to minimize residual reflection in order to avoid ghost images. Inspite of containing absorptive elements, the filters show the maximum possible transmission. This was achieved by using magnetron sputtering for the filter coating process. The most important requirement for the continuous photometric survey is the tight tolerancing of the central wavelengths and FWHM of the filters. This insures each bandpass having a defined overlap with its neighbors. In addition, the blocking of the filters is better than OD5 in the range 250-1050 nm. A high image quality required a low transmitted wavefront error (filters. λλ

  15. Numerical study of canister filters with alternatives filter cap configurations

    Science.gov (United States)

    Mohammed, A. N.; Daud, A. R.; Abdullah, K.; Seri, S. M.; Razali, M. A.; Hushim, M. F.; Khalid, A.

    2017-09-01

    Air filtration system and filter play an important role in getting a good quality air into turbo machinery such as gas turbine. The filtration system and filter has improved the quality of air and protect the gas turbine part from contaminants which could bring damage. During separation of contaminants from the air, pressure drop cannot be avoided but it can be minimized thus helps to reduce the intake losses of the engine [1]. This study is focused on the configuration of the filter in order to obtain the minimal pressure drop along the filter. The configuration used is the basic filter geometry provided by Salutary Avenue Manufacturing Sdn Bhd. and two modified canister filter cap which is designed based on the basic filter model. The geometries of the filter are generated by using SOLIDWORKS software and Computational Fluid Dynamics (CFD) software is used to analyse and simulates the flow through the filter. In this study, the parameters of the inlet velocity are 0.032 m/s, 0.063 m/s, 0.094 m/s and 0.126 m/s. The total pressure drop produce by basic, modified filter 1 and 2 is 292.3 Pa, 251.11 Pa and 274.7 Pa. The pressure drop reduction for the modified filter 1 is 41.19 Pa and 14.1% lower compared to basic filter and the pressure drop reduction for modified filter 2 is 17.6 Pa and 6.02% lower compared to the basic filter. The pressure drops for the basic filter are slightly different with the Salutary Avenue filter due to limited data and experiment details. CFD software are very reliable in running a simulation rather than produces the prototypes and conduct the experiment thus reducing overall time and cost in this study.

  16. High insulation foam glass material from waste cathode ray tube panel glass

    DEFF Research Database (Denmark)

    König, Jakob; Petersen, Rasmus Rosenlund; Yue, Yuanzheng

    . In general CRT consists of two types of glasses: barium/strontium containing glass (panel glass) and lead containing glass (funnel and panel glass). In this work we present the possibility to produce high performance insulation material from the recycled lead-free glass. We studied the influence of foaming...... between 750 and 850°C. We investigated the influence of milling time, particle size, foaming and oxidizing agent concentrations, temperature and time on the foaming process, foam density, foam porosity and homogeneity. Only moderate foaming was observed in carbon containing samples, while the addition...... of the oxidizing agent greatly improved the foaming quality. The results showed that the amount of oxygen available from the glass is not sufficient to combust all of the added carbon, therefore, additional oxygen was supplied via manganese reduction. In general, a minimum in the foam glass density was observed...

  17. Structural and magnetic properties of Ni{sub 78}Fe{sub 22} thin films sandwiched between low-softening-point glasses and application in spin devices

    Energy Technology Data Exchange (ETDEWEB)

    Misawa, Takahiro; Mori, Sumito [Research Institute for Electronic Science, Hokkaido University, Sapporo, Hokkaido 001-0020 (Japan); Komine, Takashi [Faculty of Engineering, Ibaraki University, Hitachi, Ibaraki 316-8511 (Japan); Fujioka, Masaya; Nishii, Junji [Research Institute for Electronic Science, Hokkaido University, Sapporo, Hokkaido 001-0020 (Japan); Kaiju, Hideo, E-mail: kaiju@es.hokudai.ac.jp [Research Institute for Electronic Science, Hokkaido University, Sapporo, Hokkaido 001-0020 (Japan)

    2016-12-30

    Graphical abstract: This paper presents the first demonstration of the formation of Ni{sub 78}Fe{sub 22} thin films sandwiched between low-softening-point (LSP) glasses used in spin quantum cross (SQC) devices and the theoretical prediction of spin filter effect in Ni{sub 78}Fe{sub 22}-based SQC devices. The fomation of the LSP-glass/Ni{sub 78}Fe{sub 22}/LSP-glass structures was successfully demonstrated using a newly proposed thermal pressing technique. Interestingly, this technique gives rise to both a highly-oriented crystal growth in Ni{sub 78}Fe{sub 22} thin films and a 100-fold enhancement in coercivity, in contrast to those of as-deposited Ni{sub 78}Fe{sub 22} thin films. This remarkable increase in coercivity can be explained by the calculation based on two-dimensional random anisotropy model. These excellent features on structural and magnetic properties allowed us to achieve that the stray magnetic field was uniformly generated from the Ni{sub 78}Fe{sub 22} thin-film edge in the direction perpendicular to the cross section of the LSP-glass/Ni{sub 78}Fe{sub 22}/LSP-glass structures. As we calculated the stray magnetic field generated between the two edges of Ni{sub 78}Fe{sub 22} thin-film electrodes in SQC devices, a high stray field of approximately 5 kOe was generated when the gap distance between two edges of the Ni{sub 78}Fe{sub 22} thin-film electrodes was less than 5 nm and the thickness of Ni{sub 78}Fe{sub 22} was greater than 20 nm. These experimental and calculated results suggest that Ni{sub 78}Fe{sub 22} thin films sandwiched between LSP glasses can be used as electrodes in SQC devices, providing a spin-filter effect, and also our proposed techniques utilizing magnetic thin-film edges will open up new opportunities for the creation of high performance spin devices, such as large magnetoresistance devices and nanoscale spin injectors. Our paper is of strong interest to the broad audience of Applied Surface Science, as it demonstrates that the

  18. Magnetic Glass Ceramics by Sintering of Borosilicate Glass and Inorganic Waste

    Directory of Open Access Journals (Sweden)

    Inès M. M. M. Ponsot

    2014-07-01

    Full Text Available Ceramics and glass ceramics based on industrial waste have been widely recognized as competitive products for building applications; however, there is a great potential for such materials with novel functionalities. In this paper, we discuss the development of magnetic sintered glass ceramics based on two iron-rich slags, coming from non-ferrous metallurgy and recycled borosilicate glass. The substantial viscous flow of the glass led to dense products for rapid treatments at relatively low temperatures (900–1000 °C, whereas glass/slag interactions resulted in the formation of magnetite crystals, providing ferrimagnetism. Such behavior could be exploited for applying the obtained glass ceramics as induction heating plates, according to preliminary tests (showing the rapid heating of selected samples, even above 200 °C. The chemical durability and safety of the obtained glass ceramics were assessed by both leaching tests and cytotoxicity tests.

  19. Bioactive Glass and Glass-Ceramic Scaffolds for Bone Tissue Engineering

    Directory of Open Access Journals (Sweden)

    Aldo R. Boccaccini

    2010-07-01

    Full Text Available Traditionally, bioactive glasses have been used to fill and restore bone defects. More recently, this category of biomaterials has become an emerging research field for bone tissue engineering applications. Here, we review and discuss current knowledge on porous bone tissue engineering scaffolds on the basis of melt-derived bioactive silicate glass compositions and relevant composite structures. Starting with an excerpt on the history of bioactive glasses, as well as on fundamental requirements for bone tissue engineering scaffolds, a detailed overview on recent developments of bioactive glass and glass-ceramic scaffolds will be given, including a summary of common fabrication methods and a discussion on the microstructural-mechanical properties of scaffolds in relation to human bone (structure-property and structure-function relationship. In addition, ion release effects of bioactive glasses concerning osteogenic and angiogenic responses are addressed. Finally, areas of future research are highlighted in this review.

  20. 3D Printing Prototypes for Healthcare Professionals: Creating a Reciprocating Syringe.

    Science.gov (United States)

    Rothenberg, Steven; Abdullah, Selwan; Hirsch, Jeffrey

    2017-10-01

    3D printing (additive manufacturing) has been around since 1984, but interest in the technology has increased exponentially as it has become both accessible and inexpensive. The applications of the technology in healthcare are still being explored; however, initial forays have been encouraging. It has the potential to revolutionize the process of prototyping for healthcare professionals by democratizing the process and enhancing collaboration, making it cheaper to do iterative prototyping with little or no engineering experience. This case report details the creation of a multi-lumen reciprocating syringe with 3D printing. The product has been created and tested using a variety of publicly available resources. It provides a detailed overview of the approach and the framework required to create such a medical device. However, the implications of this report are much larger than this one product, and the fundamental ideas discussed here could be used for creating customized solutions for many healthcare problems.

  1. Bioactive glasses and glass-ceramics

    Directory of Open Access Journals (Sweden)

    de Aza, P. N.

    2007-04-01

    Full Text Available Since the late 1960´s, a great interest in the use of bioceramic materials for biomedical applications has been developed. In a previous paper, the authors reviewed crystalline bioceramic materials “sensus stricto”, it is to say, those ceramic materials, constituted for non-metallic inorganic compounds, crystallines and consolidates by thermal treatment of powders at high temperature. In the present review, the authors deal with those called bioactive glasses and glassceramics. Although all of them are also obtained by thermal treatment at high temperature, the first are amorphous and the second are obtained by devitrification of a glass, although the vitreous phase normally prevails on the crystalline phases. After an introduction to the concept of bioactive materials, a short historical review of the bioactive glasses development is made. Its preparation, reactivity in physiological media, mechanism of bonding to living tissues and mechanical strength of the bone-implant interface is also reported. Next, the concept of glass-ceramic and the way of its preparation are exposed. The composition, physicochemical properties and biological behaviour of the principal types of bioactive glasses and glass-ceramic materials: Bioglass®, Ceravital®, Cerabone®, Ilmaplant® and Bioverit® are also reviewed. Finally, a short review on the bioactive-glass coatings and bioactive-composites and most common uses of bioactive-glasses and glass-ceramics are carried out too.

    Desde finales de los años sesenta, se ha despertado un gran interés por el uso de los materiales biocerámicos para aplicaciones biomédicas. En un trabajo previo, los autores hicieron una revisión de los denominados materiales biocerámicos cristalinos en sentido estricto, es decir, de aquellos materiales, constituidos por compuestos inorgánicos no metálicos, cristalinos y consolidados mediante tratamientos térmicos a altas temperaturas. En el presente trabajo, los autores

  2. Glass and vitrification

    International Nuclear Information System (INIS)

    Barton, J.L.; Vacher, R.; Moncouyoux, J.P.; Vernaz, E.

    1997-01-01

    Most glasses used as materials are oxides glasses that are produced by a quick quench of a liquid. Glasses are characterized by the absence of periodicity in the atomic arrangements, they do not have symmetries and do not present order over a long distance. This series of 4 short articles present: 1) the properties of glass and its industrial story, 2) the glass structure, 3) a forty years long story of glass as dies used to confine wastes and 4) the methodology used to study the behaviour of glass over very long periods of time. This methodology is based on 5 steps: 1) define and specify the material to study (the prediction of long term alteration of a material is nonsense unless you know well its initial properties), 2) identify all the alteration processes that are likely to happen, determine their kinetics and the influence of environmental parameters, 3) develop mathematical models in order to simulate long-term behaviour of glasses, 4) determine the release rates of the radionuclides confined in the glass, and 5) validate data and models, it is not possible to expect a complete validation of a model that will be extrapolated over tens of thousands of years, nevertheless some ways of validation can lead to a satisfactory level of confidence taking into account reasonable uncertainties. (A.C.)

  3. Glass formation, properties, and structure of soda-yttria-silicate glasses

    Science.gov (United States)

    Angel, Paul W.; Hann, Raiford E.

    1991-01-01

    The glass formation region of the soda yttria silicate system was determined. The glasses within this region were measured to have a density of 2.4 to 3.1 g/cu cm, a refractive index of 1.50 to 1.60, a coefficient of thermal expansion of 7 x 10(exp -6)/C, softening temperatures between 500 and 780 C, and Vickers hardness values of 3.7 to 5.8 GPa. Aqueous chemical durability measurements were made on select glass compositions while infrared transmission spectra were used to study the glass structure and its effect on glass properties. A compositional region was identified which exhibited high thermal expansion, high softening temperatures, and good chemical durability.

  4. Glass formation, properties and structure of soda-yttria-silica glasses

    Science.gov (United States)

    Angel, Paul W.; Hann, Raiford E.

    1992-01-01

    The glass formation region of the soda yttria silicate system was determined. The glasses within this region were measured to have a density of 2.4 to 3.1 g/cu cm, a refractive index of 1.50 to 1.60, a coefficient of thermal expansion of 7 x 10(exp -6)/C, softening temperatures between 500 and 780 C, and Vickers hardness values of 3.7 to 5.8 GPa. Aqueous chemical durability measurements were made on select glass compositions while infrared transmission spectra were used to study the glass structure and its effect on glass properties. A compositional region was identified which exhibited high thermal expansion, high softening temperatures, and good chemical durability.

  5. Production of glass or glass-ceramic to metal seals with the application of pressure

    Science.gov (United States)

    Kelly, Michael D.; Kramer, Daniel P.

    1987-11-10

    In a process for preparing a glass or glass-ceramic to metal seal comprising contacting the glass with the metal and heat-treating the glass and metal under conditions whereby the glass to metal seal is effected and, optionally, the glass is converted to a glass-ceramic, an improvement comprises carrying out the heat-treating step using hot isostatic pressing.

  6. Glass leaching performance

    International Nuclear Information System (INIS)

    Chick, L.A.; Turcotte, R.P.

    1983-05-01

    Current understanding of the leaching performance of high-level nuclear waste (HLW) glass is summarized. The empirical model of waste glass leaching behavior developed shows that at high water flow rates the glass leach rate is kinetically limited to a maximum value. At intermediate water flow rates, leaching is limited by the solution concentration of silica and decreases with decreasing water flow rates. Release of soluble elements is controlled by silica dissolution because silica forms the binding network of the glass. At low water flow rates, mass loss rates reach values controlled by formation rates of alteration minerals, or by diffusion of dissolution products through essentially stagnant water. The parameters reviewed with respect to their quantifiable influence on leaching behavior include temperature, pH, leachant composition, glass composition, thermal history, and radiation. Of these, temperature is most important since the rate of mass loss approximately doubles with each 10 0 C increase in dilute solutions. The pH has small effects within the 4 to 10 range. The chemical composition of the leachant is most important with regard to its influence on alteration product formation. Glass composition exhibits the largest effects at high flow rates where improved glasses leach from ten to thirty times slower than glass 76 to 68. The effects of the thermal history (devitrification) of the glass are not likely to be significant. Radiation effects are important primarily in that radiolysis can potentially drive pH values to less than 4. Radiation damage to the glass causes insignificant changes in leaching performance

  7. Friction behavior of glass and metals in contact with glass in various environments

    Science.gov (United States)

    Buckley, D. H.

    1973-01-01

    Sliding friction experiments have been conducted for heat-resistant glass and metals in contact with glass. These experiments were conducted in various environments including vacuum, moist air, dry air, octane, and stearic acid in hexadecane. Glass exhibited a higher friction force in moist air than it did in vacuum when in sliding contact with itself. The metals, aluminum, iron, and gold, all exhibited the same friction coefficient when sliding on glass in vacuum as glass sliding on glass. Gold-to-glass contacts were extremely sensitive to the environment despite the relative chemical inertness of gold.

  8. An open-label, multicenter study to evaluate the safe and effective use of the single-use autoinjector with an Avonex® prefilled syringe in multiple sclerosis subjects

    Directory of Open Access Journals (Sweden)

    Tuccillo Dianne

    2011-10-01

    Full Text Available Abstract Background The ability to self-inject in patients with multiple sclerosis (MS has been associated with a reduced risk of missed injections and drug discontinuation, and a beneficial effect on patients' independence. However, injection anxiety, needle phobia and disease-related disability are major barriers to a patient's ability to self-administer treatment. Use of an autoinjector may improve patients' ability to self-inject. This study evaluated the safe and effective use of Avonex Pen™ (prefilled pen, a single use autoinjector, for intramuscular delivery of interferon beta-1a (IM IFNβ-1a, Avonex in MS patients. Methods This was a Phase IIIb, open-label, single-country, multicenter trial in MS patients currently using IM IFNβ-1a prefilled syringes. Patients received weekly 30 mcg IM IFNβ-1a treatment over 4 weeks. On Day 1, patients self-administered IM IFNβ-1a using a prefilled syringe at the clinic. On Day 8, patients received training on the prefilled pen and self-administered IM IFNβ-1a using the device. On Day 15, patients self-administered IM IFNβ-1a at home using the prefilled pen. A final injection occurred at the clinic on Day 22 when patients self-administered IM IFNβ-1a using the prefilled pen while clinic staff observed and completed a detailed questionnaire documenting patients' ability to self-inject with the device. Serum neopterin levels were evaluated pre and post-injection on Days 1 and 8. Adverse events were monitored throughout. Results Seventy-one (96% patients completed the study. The overall success rate in safely and effectively using the prefilled pen was 89%. No device malfunctions occurred. One unsuccessful administration occurred at Day 22 due to patient error; no patient injury resulted. Patients gave the prefilled pen high ratings (8.7-9.3 on a 10-point scale for ease of use (0 = extremely difficult, 10 = extremely easy. Ninety-four percent of patients preferred the prefilled pen over the

  9. Glass Property Data and Models for Estimating High-Level Waste Glass Volume

    Energy Technology Data Exchange (ETDEWEB)

    Vienna, John D.; Fluegel, Alexander; Kim, Dong-Sang; Hrma, Pavel R.

    2009-10-05

    This report describes recent efforts to develop glass property models that can be used to help estimate the volume of high-level waste (HLW) glass that will result from vitrification of Hanford tank waste. The compositions of acceptable and processable HLW glasses need to be optimized to minimize the waste-form volume and, hence, to save cost. A database of properties and associated compositions for simulated waste glasses was collected for developing property-composition models. This database, although not comprehensive, represents a large fraction of data on waste-glass compositions and properties that were available at the time of this report. Glass property-composition models were fit to subsets of the database for several key glass properties. These models apply to a significantly broader composition space than those previously publised. These models should be considered for interim use in calculating properties of Hanford waste glasses.

  10. Glass Property Data and Models for Estimating High-Level Waste Glass Volume

    International Nuclear Information System (INIS)

    Vienna, John D.; Fluegel, Alexander; Kim, Dong-Sang; Hrma, Pavel R.

    2009-01-01

    This report describes recent efforts to develop glass property models that can be used to help estimate the volume of high-level waste (HLW) glass that will result from vitrification of Hanford tank waste. The compositions of acceptable and processable HLW glasses need to be optimized to minimize the waste-form volume and, hence, to save cost. A database of properties and associated compositions for simulated waste glasses was collected for developing property-composition models. This database, although not comprehensive, represents a large fraction of data on waste-glass compositions and properties that were available at the time of this report. Glass property-composition models were fit to subsets of the database for several key glass properties. These models apply to a significantly broader composition space than those previously publised. These models should be considered for interim use in calculating properties of Hanford waste glasses.

  11. Porous Metal Filters for Gas and Liquid Applications in the Nuclear Industry

    International Nuclear Information System (INIS)

    Kenneth, Rubow

    2009-01-01

    Sintered metal media are ideally suited for use in the most demanding industrial applications where long life is required and often other media are not cost-effective solution. As examples, filtration technology utilizing sintered metal media provides excellent performance in numerous liquid/solids and gas/solid separation applications found in the handling and processing of fluids containing radioactive materials. Many types of filter media, ranging from single use (disposable) to semi-permanent, are utilized today for separation of particulate matter. However, semi-permanent media are usually cleanable, either on or off-line, and are intended for sustainable, often multi-year, operating life in harsh environments. These harsh environments, which may involve corrosive fluids, high temperatures, high pressures or pressure spikes, often requiring continuous filtration service, are ideally suited for all-metal filtration systems employing semi-permanent sintered metal media. Sintered metal media, usually fabricated into tubular metal elements, have proven high particle removal efficiency and demonstrated reliability that uniquely afford excellent performance for demanding liquid/solids and gas/solids separation processes. The filter element and, in certain cases, the entire filter are weldable; therefore, the inherent sealing eliminates the need for potentially problematic seals. These media provide a positive barrier to ensure particulate removal to protect downstream equipment, for product separation, and/or to meet health, safety and environmental regulations. Typical applications for sintered metal media include: 1) gas and liquid filter systems used in various nuclear and radioactive waste processing applications, 2) an all-metal High Efficiency Particulate Air (HEPA) filter developed under Department of Energy (DOE) funding as an alternative to traditional HEPA filters fabricated with conventional glass fibers used on High Level Waste (HLW) tank ventilation

  12. Can painted glass felt or glass fibre cloth be used as vapour barrier?

    DEFF Research Database (Denmark)

    El-Khattam, Amira; Andersen, Mie Them; Hansen, Kurt Kielsgaard

    2014-01-01

    In most Nordic homes the interior surfaces of walls and ceilings have some kind of surface treatment for aesthetical reasons. The treatments can for example be glass felt or glass fibre cloth which are painted afterwards. To evaluate the hygrothermal performance of walls and ceilings...... treatments. The surface treatments were glass felt or glass fibre cloth with different types of paints or just paint. The paint types were acrylic paint and silicate paint. The results show that the paint type has high influence on the water vapour resistance while the underlay i.e. glass felt or glass fibre...... acrylic paint on glass felt or glass fibre cloth cannot be used instead of a vapour barrier....

  13. Numerical study of the glass-glass transition in short-ranged attractive colloids

    International Nuclear Information System (INIS)

    Zaccarelli, Emanuela; Sciortino, Francesco; Tartaglia, Piero

    2004-01-01

    We report extensive numerical simulations in the glass region for a simple model of short-ranged attractive colloids, the square well model. We investigate the behaviour of the density autocorrelation function and of the static structure factor in the region of temperatures and packing fractions where a glass-glass transition is expected according to theoretical predictions. We strengthen our observations by studying both waiting time and history dependence of the numerical results. We provide evidence supporting the possibility that activated bond-breaking processes destabilize the attractive glass, preventing the full observation of a sharp glass-glass kinetic transition

  14. Studies on Bi-Sr-Ca-Cu-O glasses and superconducting glass ceramics

    International Nuclear Information System (INIS)

    Singh, R.; Zacharias, E.

    1991-01-01

    Bi-Sr-Ca-Cu-O glasses and glass ceramics of various compositions were synthesised. The glass transition temperature varies from 396 to 422degC depending on the glass composition. The bulk glass ceramics of 4334, 4336, 2223 and 4246 compositions show superconductivity when the corresponding glass samples were heat-treated in air at 820degC for 3, 9, 12 and 24 h respectively. X-ray diffraction studies show that the superconducting phase present in all these compositions is Bi 2 Sr 2 Ca 1 Cu 2 O x . The 4334 glass ceramic is almost a single-phase material with a preferred orientation such that the c axis is normal to the sample surface. The 2223 glass ceramic has a higher T c (onset) than the other three compositions indicating the presence of high T c phase (110 K) also. ESR studies on the glass samples indicate the existence of Cu 2+ . The effect of heat treatment on ESR shows that the intensity of resonance decreases with increase in heat-treatment duration. This effect is more pronounced for the 4334 and 2223 compositions. The advantages of synthesizing superconducting materials by glass route are discussed in view of practical applications. (author). 9 refs., 6 figs

  15. Spin glasses

    CERN Document Server

    Bovier, Anton

    2007-01-01

    Spin glass theory is going through a stunning period of progress while finding exciting new applications in areas beyond theoretical physics, in particular in combinatorics and computer science. This collection of state-of-the-art review papers written by leading experts in the field covers the topic from a wide variety of angles. The topics covered are mean field spin glasses, including a pedagogical account of Talagrand's proof of the Parisi solution, short range spin glasses, emphasizing the open problem of the relevance of the mean-field theory for lattice models, and the dynamics of spin glasses, in particular the problem of ageing in mean field models. The book will serve as a concise introduction to the state of the art of spin glass theory, usefull to both graduate students and young researchers, as well as to anyone curious to know what is going on in this exciting area of mathematical physics.

  16. A method for making a glass supported system, such glass supported system, and the use of a glass support therefor

    NARCIS (Netherlands)

    Unnikrishnan, S.; Jansen, Henricus V.; Berenschot, Johan W.; Fazal, I.; Louwerse, M.C.; Mogulkoc, B.; Sanders, Remco G.P.; de Boer, Meint J.; Elwenspoek, Michael Curt

    2008-01-01

    The invention relates to a method for making a glass supported micro or nano system, comprising the steps of: i) providing a glass support; ii) mounting at least one system on at least one glass support; and iii) bonding the system to the glass support, such that the system is circumferentially

  17. Binary eutectic clusters and glass formation in ideal glass-forming liquids

    International Nuclear Information System (INIS)

    Lu, Z. P.; Shen, J.; Xing, D. W.; Sun, J. F.; Liu, C. T.

    2006-01-01

    In this letter, a physical concept of binary eutectic clusters in 'ideal' glass-forming liquids is proposed based on the characteristics of most well-known bulk metallic glasses (BMGs). The authors approach also includes the treatment of binary eutectic clusters as basic units, which leads to the development of a simple but reliable method for designing BMGs more efficiently and effectively in these unique glass-forming liquids. As an example, bulk glass formers with superior glass-forming ability in the Zr-Ni-Cu-Al and Zr-Fe-Cu-Al systems were identified with the use of the strategy

  18. Controlling flow conditions of test filters in iodine filters

    International Nuclear Information System (INIS)

    Holmberg, R.; Laine, J.

    1979-03-01

    Several different iodine filter and test filter designs and experience gained from their operation are presented. For the flow experiments, an iodine filter system equipped with flow regulating and measuring devices was built. In the experiments the influence of the packing method of the iodine sorption material and the influence of the flow regulating and measuring divices upon the flow conditions in the test filters was studied. On the basis of the experiments it has been shown that the flows through the test filters always can be adjusted to a correct value if there only is a high enough pressure difference available across the test filter ducting. As a result of the research, several different methods are presented with which the flows through the test filters in both operating and future iodine sorption system can easily be measured and adjusted to their correct values. (author)

  19. A simple method for tuning the glass transition process in inorganic phosphate glasses

    Science.gov (United States)

    Fulchiron, René; Belyamani, Imane; Otaigbe, Joshua U.; Bounor-Legaré, Véronique

    2015-02-01

    The physical modification of glass transition temperature (Tg) and properties of materials via blending is a common practice in industry and academia and has a large economic advantage. In this context, simple production of hitherto unattainable new inorganic glass blends from already existing glass compositions via blending raises much hope with the potential to provide new glasses with new and improved properties, that cannot be achieved with classical glass synthesis, for a plethora of applications such as computers screens, glass-to-metal seals, and storage materials for nuclear wastes. Here, we demonstrate that blends of the specific glass compositions studied are miscible in all proportions, an unreported phenomenon in hard condensed matter like glass. Interestingly, excellent agreement was found between the obtained data and calculated Tgs from theoretical equations (Supplementary information) for predicting the composition dependence of Tg for miscible blends with weak but significant specific interactions between the blend components. That this blending method is at present not applied to inorganic glasses reflects the fact that water and chemically resistant phosphate glasses with relatively low Tgs have become available only recently.

  20. The Rao-Blackwellized Particle Filter: A Filter Bank Implementation

    Directory of Open Access Journals (Sweden)

    Karlsson Rickard

    2010-01-01

    Full Text Available For computational efficiency, it is important to utilize model structure in particle filtering. One of the most important cases occurs when there exists a linear Gaussian substructure, which can be efficiently handled by Kalman filters. This is the standard formulation of the Rao-Blackwellized particle filter (RBPF. This contribution suggests an alternative formulation of this well-known result that facilitates reuse of standard filtering components and which is also suitable for object-oriented programming. Our RBPF formulation can be seen as a Kalman filter bank with stochastic branching and pruning.

  1. Convergent Filter Bases

    Directory of Open Access Journals (Sweden)

    Coghetto Roland

    2015-09-01

    Full Text Available We are inspired by the work of Henri Cartan [16], Bourbaki [10] (TG. I Filtres and Claude Wagschal [34]. We define the base of filter, image filter, convergent filter bases, limit filter and the filter base of tails (fr: filtre des sections.

  2. The Fate of Mengovirus on Fiberglass Filter of Air Handling Units.

    Science.gov (United States)

    Bandaly, Victor; Joubert, Aurélie; Le Cann, Pierre; Andres, Yves

    2017-12-01

    One of the most important topics that occupy public health problems is the air quality. That is the reason why mechanical ventilation and air handling units (AHU) were imposed by the different governments in the collective or individual buildings. Many buildings create an artificial climate using heating, ventilation, and air-conditioning systems. Among the existing aerosols in the indoor air, we can distinguish the bioaerosol with biological nature such as bacteria, viruses, and fungi. Respiratory viral infections are a major public health issue because they are usually highly infective. We spend about 90% of our time in closed environments such as homes, workplaces, or transport. Some studies have shown that AHU contribute to the spread and transport of viral particles within buildings. The aim of this work is to study the characterization of viral bioaerosols in indoor environments and to understand the fate of mengovirus eukaryote RNA virus on glass fiber filter F7 used in AHU. In this study, a set-up close to reality of AHU system was used. The mengovirus aerosolized was characterized and measured with the electrical low pressure impact and the scanner mobility particle size and detected with RT-qPCR. The results about quantification and the level of infectivity of mengovirus on the filter and in the biosampler showed that mengovirus can pass through the filter and remain infectious upstream and downstream the system. Regarding the virus infectivity on the filter under a constant air flow, mengovirus was remained infectious during 10 h after aerosolization.

  3. Syringe needle skull penetration reduces brain injuries and secondary inflammation following intracerebral neural stem cell transplantation.

    Science.gov (United States)

    Gao, Mou; Dong, Qin; Zhang, Hongtian; Yang, Yang; Zhu, Jianwei; Yang, Zhijun; Xu, Minhui; Xu, Ruxiang

    2017-03-01

    Intracerebral neural stem cell (NSC) transplantation is beneficial for delivering stem cell grafts effectively, however, this approach may subsequently result in brain injury and secondary inflammation. To reduce the risk of promoting brain injury and secondary inflammation, two methods were compared in the present study. Murine skulls were penetrated using a drill on the left side and a syringe needle on the right. Mice were randomly divided into three groups (n=84/group): Group A, receiving NSCs in the left hemisphere and PBS in the right; group B, receiving NSCs in the right hemisphere and PBS in the left; and group C, receiving equal NSCs in both hemispheres. Murine brains were stained for morphological analysis and subsequent evaluation of infiltrated immune cells. ELISA was performed to detect neurotrophic and immunomodulatory factors in the brain. The findings indicated that brain injury and secondary inflammation in the left hemisphere were more severe than those in the right hemisphere, following NSC transplantation. In contrast to the left hemisphere, more neurotrophic factors but less pro-inflammatory cytokines were detected in the right hemisphere. In addition, increased levels of neurotrophic factors and interleukin (IL)-10 were observed in the NSC transplantation side when compared with the PBS-treated hemispheres, although lower levels of IL-6 and tumor necrosis factor-α were detected. In conclusion, the present study indicated that syringe needle skull penetration vs. drill penetration is an improved method that reduces the risk of brain injury and secondary inflammation following intracerebral NSC transplantation. Furthermore, NSCs have the potential to modulate inflammation secondary to brain injuries.

  4. Extraction of mandibular premolars and molars: comparison between local infiltration via pressure syringe and inferior alveolar nerve block anesthesia.

    Science.gov (United States)

    Thiem, Daniel G E; Schnaith, Florian; Van Aken, Caroline M E; Köntges, Anne; Kumar, Vinay V; Al-Nawas, Bilal; Kämmerer, Peer W

    2018-04-01

    The purpose of this study was to evaluate the anesthetic efficiency of local infiltration anesthesia administered with a pressure syringe (P-INF) via a special technique versus direct block anesthesia of the inferior alveolar nerve (IANB) for tooth extraction in the posterior mandible. In a prospective randomized study, 101 teeth in 101 patients were extracted in the posterior mandible under local anesthesia whereby two different administration techniques were used (P-INF n = 48; IANB n = 53). Primary objectives were comparisons of anesthetic success rate (yes/no) and efficacy (full/sufficient vs. insufficient). Secondary objectives were patients' pain perception during treatment, pain of injection (numerical rating scale), need for second injections (always IANB), time until onset of anesthetic action (min), and duration of local numbness (min). IANB was successful in all cases, whereas initial P-INF achieved 35% of success only. Furthermore, IANB reached significant higher values of anesthetic efficacy compared to P-INF (P block anesthesia of the inferior alveolar nerve (IANB) turned out to be more proficient to local infiltration via special delivering system with a special technique. Infiltration, even when performed with 4% articaine and a pressure syringe system, is not a suitable method of anesthesia in the posterior mandible.

  5. Glasses

    DEFF Research Database (Denmark)

    Dyre, Jeppe

    2004-01-01

    The temperature dependence of the viscosity of most glassforming liquids is known to depart significantly from the classical Arrhenius behaviour of simple fluids. The discovery of an unexpected correlation between the extent of this departure and the Poisson ratio of the resulting glass could lead...... to new understanding of glass ageing and viscous liquid dynamics....

  6. Phytate degradation by Leuconostoc mesenteroides KC51 ...

    African Journals Online (AJOL)

    STORAGESEVER

    2009-07-06

    Jul 6, 2009 ... The mixture was stirred on a vortex mixer and then filtered with 0.45. µm syringe filter; the absorbance of the filtrate was read at 500 nm. Concentration of phytate was shown mean values and standard deviation (n=3). RESULTS AND DISCUSSION. To evaluate the phytate breakdown activity of lactic acid.

  7. Application of DFT Filter Banks and Cosine Modulated Filter Banks in Filtering

    Science.gov (United States)

    Lin, Yuan-Pei; Vaidyanathan, P. P.

    1994-01-01

    None given. This is a proposal for a paper to be presented at APCCAS '94 in Taipei, Taiwan. (From outline): This work is organized as follows: Sec. II is devoted to the construction of the new 2m channel under-decimated DFT filter bank. Implementation and complexity of this DFT filter bank are discussed therein. IN a similar manner, the new 2m channel cosine modulated filter bank is discussed in Sec. III. Design examples are given in Sec. IV.

  8. The Perfect Glass Paradigm: Disordered Hyperuniform Glasses Down to Absolute Zero

    Science.gov (United States)

    Zhang, G.; Stillinger, F. H.; Torquato, S.

    2016-11-01

    Rapid cooling of liquids below a certain temperature range can result in a transition to glassy states. The traditional understanding of glasses includes their thermodynamic metastability with respect to crystals. However, here we present specific examples of interactions that eliminate the possibilities of crystalline and quasicrystalline phases, while creating mechanically stable amorphous glasses down to absolute zero temperature. We show that this can be accomplished by introducing a new ideal state of matter called a “perfect glass”. A perfect glass represents a soft-interaction analog of the maximally random jammed (MRJ) packings of hard particles. These latter states can be regarded as the epitome of a glass since they are out of equilibrium, maximally disordered, hyperuniform, mechanically rigid with infinite bulk and shear moduli, and can never crystallize due to configuration-space trapping. Our model perfect glass utilizes two-, three-, and four-body soft interactions while simultaneously retaining the salient attributes of the MRJ state. These models constitute a theoretical proof of concept for perfect glasses and broaden our fundamental understanding of glass physics. A novel feature of equilibrium systems of identical particles interacting with the perfect-glass potential at positive temperature is that they have a non-relativistic speed of sound that is infinite.

  9. Fabrication of highly insulating foam glass made from CRT panel glass

    DEFF Research Database (Denmark)

    König, Jakob; Petersen, Rasmus Rosenlund; Yue, Yuanzheng

    2015-01-01

    We prepared low-density foam glasses from cathode-ray-tube panel glass using carbon and MnO2 as the foaming agents. We investigated the influence of the carbon and MnO2 concentrations, the glass-powder preparation and the foaming conditions on the density and homogeneity of the pore structure...... and the dependence of the thermal conductivity on the foam density. The results show that the moderate foaming effect of the carbon is greatly improved by the addition of MnO2. A density as low as 131 kg m-3 can be achieved with fine glass powder. The foam density has a slight dependence on the carbon and MnO2...... concentrations, but it is mainly affected by the foaming temperature and the time. The thermal conductivity of the foam-glass samples is lower than that of commercial foam glasses with the same density. The lowest value was determined to be 42 mW m-1 K-1 for a foam glass with a density of 131 kg m-3. A further...

  10. Crack tip fracture toughness of base glasses for dental restoration glass-ceramics using crack opening displacements.

    Science.gov (United States)

    Deubener, J; Höland, M; Höland, W; Janakiraman, N; Rheinberger, V M

    2011-10-01

    The critical stress intensity factor, also known as the crack tip toughness K(tip), was determined for three base glasses, which are used in the manufacture of glass-ceramics. The glasses included the base glass for a lithium disilicate glass-ceramic, the base glass for a fluoroapatite glass-ceramic and the base glass for a leucite glass-ceramic. These glass-ceramic are extensively used in the form of biomaterials in restorative dental medicine. The crack tip toughness was established by using crack opening displacement profiles under experimental conditions. The crack was produced by Vickers indentation. The crack tip toughness parameters determined for the three glass-ceramics differed quite significantly. The crack tip parameters of the lithium disilicate base glass and the leucite base glass were higher than that of the fluoroapatite base glass. This last material showed glass-in-glass phase separation. The discussion of the results clearly shows that the droplet glass phase is softer than the glass matrix. Therefore, the authors conclude that a direct relationship exists between the chemical nature of the glasses and the crack tip parameter. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. Magnetic Glass Ceramics by Sintering of Borosilicate Glass and Inorganic Waste

    OpenAIRE

    Ponsot, In?s M. M. M.; Pontikes, Yiannis; Baldi, Giovanni; Chinnam, Rama K.; Detsch, Rainer; Boccaccini, Aldo R.; Bernardo, Enrico

    2014-01-01

    Ceramics and glass ceramics based on industrial waste have been widely recognized as competitive products for building applications; however, there is a great potential for such materials with novel functionalities. In this paper, we discuss the development of magnetic sintered glass ceramics based on two iron-rich slags, coming from non-ferrous metallurgy and recycled borosilicate glass. The substantial viscous flow of the glass led to dense products for rapid treatments at relatively low te...

  12. Recycling of post-consumer glass: energy savings, CO2 emission reduction, effects on glass quality and glass melting

    NARCIS (Netherlands)

    Beerkens, R.G.C.; Kers, G.; Santen, E. van

    2011-01-01

    This presentation shows the advantages of re-melting post-consumer glass, but also the potential risks of using contaminated cullet in the raw material batch of glass furnaces (e.g. container glass furnaces). As an example of potential advantages: increasing the cullet % in the batch of an efficient

  13. Silicate glasses. Chapter 1

    International Nuclear Information System (INIS)

    Lutze, W.

    1988-01-01

    This chapter is a survey of world-wide research and development efforts in nuclear waste glasses and its production technology. The principal glasses considered are silicate glasses which contain boron, i.e. borosilicate glass. A historical overview of waste form development programs in nine countries is followed by a summary of the design criteria for borosilicate glass compositions glass compositions. In the sections on glass properties the waste form is characterized in terms of potential alterations under the influence of heat, thermal gradients, radiation, aqueous solutions and combinations thereof. The topics are phase transformations, mechanical properties, radiation effects and chemical durability. The results from studies of volcanic glasses, as natural analogues for borosilicate nuclear waste glasses in order to verify predictions obtained from short-term tests in the laboratory, have been compiled in a special section on natural analogues. A special section on advanced vitrification techniques summarizes the various actual and potential processing schemes and describes the facilities. The literature has been considered until 1985. (author). 430 refs.; 68 figs.; 29 tabs

  14. A Study of Parallel Operation of an active Filter and passive Filters

    DEFF Research Database (Denmark)

    Chen, Zhe; Blaabjerg, Frede; Pedersen, John Kim

    2002-01-01

    This paper reports investigations of the parallel operations of a current controlled active filter and passive filters in a system with current harmonic sources. The task of reactive power and harmonic compensation is shared by the active filter and passive filters. The passive filters are used...... arrangements of the active and passive filters can operate relatively independently, also the compensation flexibility of the active filter can be fully exploited, such as one active filter for several harmonic sources.The simulation studies on various systems have been performed to evaluate the effectiveness...... of the systems. The results show that the power factor is corrected by the passive filters, harmonics are minimized by both active and passive filters and overloading of the filter system can be avoided....

  15. Passive Power Filters

    CERN Document Server

    Künzi, R.

    2015-06-15

    Power converters require passive low-pass filters which are capable of reducing voltage ripples effectively. In contrast to signal filters, the components of power filters must carry large currents or withstand large voltages, respectively. In this paper, three different suitable filter struc tures for d.c./d.c. power converters with inductive load are introduced. The formulas needed to calculate the filter components are derived step by step and practical examples are given. The behaviour of the three discussed filters is compared by means of the examples. P ractical aspects for the realization of power filters are also discussed.

  16. Predicting the glass transition temperature of bioactive glasses from their molecular chemical composition.

    Science.gov (United States)

    Hill, Robert G; Brauer, Delia S

    2011-10-01

    A recently published paper (M.D. O'Donnell, Acta Biomaterialia 7 (2011) 2264-2269) suggests that it is possible to correlate the glass transition temperature (T(g)) of bioactive glasses with their molar composition, based on iterative least-squares fitting of published T(g) data. However, we show that the glass structure is an important parameter in determining T(g). Phase separation, local structural effects and components (intermediate oxides) which can switch their structural role in the glass network need to be taken into consideration, as they are likely to influence the glass transition temperature of bioactive glasses. Although the model suggested by O'Donnell works reasonably well for glasses within the composition range presented, it is oversimplified and fails for glasses outside certain compositional boundaries. Copyright © 2011 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  17. Effect of Gamma Irradiation on Some Properties of Bismuth Silicate Glasses and Their Glass Derivatives

    International Nuclear Information System (INIS)

    Abo Hussein, E.M.K.

    2014-01-01

    Glasses containing bismuth oxide have attracted considerable attention, although it is non-conventional glass forming oxide, but it has wide applications. In this work, it is aimed to prove that bismuth silicate glass can act as a good shielding material for γ- rays. For this purpose glass containing 20% bismuth oxide and 80% SiO_2 was prepared using melting-annealing technique. Also effects of adding some alkali heavy metal oxides to this glass such as PbO, BaO or SrO were also studied. The formed glasses were also heat treated at 450 degree C for 4 hours to give the corresponding heat treated glasses. Electron Paramagnetic Resonance (EPR) measurements show that the prepared glasses and heat treated glasses have very good stability when exposed to γ- irradiation, which encourage the assumption of using these glasses as gamma ray shielding materials. Many properties have been investigated, such as density to understand the structural properties, also mechanical properties were verified by measuring microhardness, while the chemical resistance was identified by testing their durability in both acidic and basic solutions. The EPR results were supported by measuring electrical conductivity of the glass and heat treated glass samples at different temperatures ranging from 298 to 553 K, which proved that these glasses have very low conductivity even at high temperature. The formed phases of heat treated glass or glass ceramic samples were demonstrated by means of X-ray diffraction (XRD). Also studying the structure of glasses and heat treated glasses before and after irradiation was investigated by the Infrared transmitting spectra. Calculations of optical band gap energies were demonstrated for some selected glasses and heat treated glasses from the data of UV optical absorption spectra to support the probability of using these bismuth silicate glasses for gamma radiation shielding processing.

  18. Temperature profiles for laser-induced heating of nanocrystals embedded in glass matrices

    Science.gov (United States)

    Bhatnagar, Promod K.; Nagpal, Swati

    2001-05-01

    Quantum confined nanostructures are very important because of their application towards optoelectronic devices. Commercial colored glass filters, which have large semiconductor particles, are being used to manufacture nanocrystals by suitable heat treatments. The progress in this area has been hampered by high size dispersion of these dots in the glass matrix which leads to reduction in higher order susceptibility thereby reducing non-linearity. In the present paper attempt has been made to theoretically model the temperature profiles of a laser irradiated CdS doped Borosilicate sample. Laser being used has a beam diameter of 1.5 mm and energy for 10 nsec pulse is 10 mJ. Two different particle radii of 5 nm and 10 nm have been considered. It is found that larger particles reach higher temperatures for the same pulse characteristics. This is because smaller particles have larger surface to volume ratio and hence dissipates out heat faster to the surrounding. Hence bigger particles will reach dissolution temperature faster than smaller particle and particle beyond a certain size should dissolve in the glass matrix when a sample is heat treated by laser. This could lead to a reduction in size dispersion of the nanocrystals. Also photodarkening effect found in semiconductor doped glasses is a big handicap for practical application of these materials in fast optical switching and non-linear optical devices. Photodarkening effect has been established to be a photochemical effect and it is important to study the temperature profiles around a particle since it will effect the impurity migration.

  19. Investigations into the penetration and pressure drop of HEPA filter media during loading with submicron particle aerosols at high concentrations

    International Nuclear Information System (INIS)

    Leibold, H; Wilhelm, J.G.

    1991-01-01

    High Efficiency Particulate Air (HEPA) filters are typically employed in particle removal and retention within the air cleaning systems of clean rooms in the pharmaceutical, nuclear and semiconductor industries for dust concentrations of some μg/m 3 . Their extremely high removal efficiencies for submicron particles make them attractive candidates in complying with increasingly lower emission limits for industrial processes that involve dust concentrations of up to several g/m 3 . Cost-effective operation under such conditions requires the filter units to be recleanable. The recleanability of HEPA filter media depends not only on the operating conditions during the cleaning process but also on the filtration conditions during particle loading. The structure and location of the particles captured by the glass fiber matrix greatly affect the degree to which they can be subsequently dislodged and removed from the filter medium. Changes in filtration efficiency with service time for various particle diameters in the critical submicron size range, as well as the effects of filtration velocity on the increase in pressure drop, are important criteria with regard to recleaning HEPA filter units. Of special significance for the recleanability of HEPA filter media is knowledge of how operating conditions affect dust cake formation. (author)

  20. Glass heat capacity and its abrupt change in glass transition region

    DEFF Research Database (Denmark)

    Yue, Yuanzheng; Smedskjær, Morten Mattrup; Mauro, John C.

    cover a large range of glass formers from metallic to non-metallic glasses. To conduct this study we convert the units of all the Cp data from J/mol K and J/g K to J/g-atom K. This study will provide insight into the correlations among chemical bonding, microstructure structure, liquid fragility, glass......Glass transition (GT) has been a fascinating, but challenging subject in the condensed matter science over decades. Despite progress in understanding GT, many crucial problems still need to be clarified. One of the problems deals with the microscopic origin of abrupt change of heat capacity (Cp......) around glass transition. Here we study this problem through two approaches. First, we analyze the Cp change with temperature on homologous series of glass formers (i.e., with regular compositional substitution). Second, we do the same on non-homologous systems (e.g. without regular compositional...

  1. Air radioactivity: to assess risks. Tools answer citizen questions. The Opera-Air network: the journey of a filter

    International Nuclear Information System (INIS)

    Didier, Damien; Gariel, Jean-Christophe; Bruno, Valerie; Debayle, Christophe

    2017-01-01

    Very highly efficient filters containing a porous glass fibre fabric are used in industrial installations to trap radioactive or toxic particles in order to limit their release, notably in accidental situations. Thus this set of articles discusses various issues related to the use of such filters. A first one describes how air radioactivity is continuously monitored by two coexisting networks: Opera-Air and Teleray. It indicates where air radioactivity comes from, and how the origin of a release can be determined, and outlines the importance of modelling tools. Air monitoring about the Gravelines nuclear power plant is briefly presented with a drawing. A second article comments the existence of numerous tools which are used as information channels about the monitoring of air radioactivity: web sites, mobile application, and so on. The last article briefly describes the journey of a filter from its removal on a Monday to a complete and validated analysis which lasts between two and four weeks

  2. Chiral-glass transition and replica symmetry breaking of a three-dimensional Heisenberg spin glass

    OpenAIRE

    Hukushima, K.; Kawamura, H.

    2000-01-01

    Extensive equilibrium Monte Carlo simulations are performed for a three-dimensional Heisenberg spin glass with the nearest-neighbor Gaussian coupling to investigate its spin-glass and chiral-glass orderings. The occurrence of a finite-temperature chiral-glass transition without the conventional spin-glass order is established. Critical exponents characterizing the transition are different from those of the standard Ising spin glass. The calculated overlap distribution suggests the appearance ...

  3. Effect of small glass composition changes on flue gas emissions of glass furnaces

    NARCIS (Netherlands)

    Limpt, J.A.C. van; Beerkens, R.G.C.; Kersbergen, M.J. van

    2008-01-01

    Relatively small changes in glass composition might have drastic consequences on the evaporation rates of volatile glass components in glass melting furnaces. Transpiration evaporation tests have been applied to measure the impact of minor glass composition changes on the evaporation rates of

  4. Restorative glass: reversible, discreet restoration using structural glass components

    Directory of Open Access Journals (Sweden)

    Faidra Oikonomopoulou

    2017-12-01

    Full Text Available The application of structural glass as the principal material in restoration and conservation practices is a distinguishable, yet discreet approach. The transparency of glass allows the simultaneous perception of the monument at both its original and present condition, preserving its historical and aesthetical integrity. Concurrently, the material’s unique mechanical properties enable the structural consolidation of the monument. As a proof of concept, the restoration of Lichtenberg Castle is proposed. Solid cast glass units are suggested to complete the missing parts, in respect to the existing construction technique and aesthetics of the original masonry. Aiming for a reversible system, the glass units are interlocking, ensuring the overall stability without necessitating permanent, adhesive connections. This results in an elegant and reversible intervention.

  5. SU-F-T-57: Delivered Activity Accuracy of Radium 223 Dichloride Injections, When Being Administrated for Castration Resistant Prostate Cancer, Symptomatic Bone Metastases. The Impact of Residual Activity in the Spent Syringe and Dispensing Accuracy of Ra 223

    International Nuclear Information System (INIS)

    Jennings, G

    2016-01-01

    Purpose: To quantify the delivered activity accuracy of Radium 223 dichloride injections, when being administrated for castration – resistant prostate cancer, symptomatic bone metastases. The impact of residual activity in the spent syringe and dispensing accuracy of Ra 223. Methods: The administration is by slow intravenous injection over 1 minute followed by double flushing of the 10 mL syringe and IV with saline. Eighty (80) procedures was used to investigate variations in the activity from the amount prescribed (µCi) = 1.35 × Patient weight Kg. The Activity dispensed into a 10mL syringe using a NIST traceable Capintec CRC-25R Chamber and a cross calibrated capintec CRC-15R to measure activity in the syringe immediately before and after administration Results: The patients weight range from 121Ib to 235lb and doses ranging 74.25 µCi to 144.2 µCi. The deviation of dispensed dose vs Prescribed dose average +2.1% with a range of −1.1% to +5.7%. The Dose measured before administration ranges 79.3 µCi to 154.9 µCi. Deviation from the dispensed dose was show to average +2.9% with a range of −0.8% to +7.3%. The average residual dose post injection was 2.5 µCi or 2.2% of the pre injection activity. Ranging from 0.9 µCi to 6.2 µCi, 0.7% to 5.4% respectively. Subtracting the residual activity from that measured activity before injection and comparing it to prescription dose was shown to have an average variation of +2.7% with a range of −0.8% to 7.4%. Conclusion: The case resulted in the 6.2 µCi maximum residual dose had two syringes. A small, 82.8 µCi activity, case resulted in the 7.4% maximum variation in measures less residual verses prescription dose. The average +2.1 % dispenses activity of Ra 223 over the prescription dosage was seen to counteract the average 2.2% residual dosage found to remain in the syringe

  6. SU-F-T-57: Delivered Activity Accuracy of Radium 223 Dichloride Injections, When Being Administrated for Castration Resistant Prostate Cancer, Symptomatic Bone Metastases. The Impact of Residual Activity in the Spent Syringe and Dispensing Accuracy of Ra 223

    Energy Technology Data Exchange (ETDEWEB)

    Jennings, G [Marsden Medical Physics Associates, Denville, NJ (United States)

    2016-06-15

    Purpose: To quantify the delivered activity accuracy of Radium 223 dichloride injections, when being administrated for castration – resistant prostate cancer, symptomatic bone metastases. The impact of residual activity in the spent syringe and dispensing accuracy of Ra 223. Methods: The administration is by slow intravenous injection over 1 minute followed by double flushing of the 10 mL syringe and IV with saline. Eighty (80) procedures was used to investigate variations in the activity from the amount prescribed (µCi) = 1.35 × Patient weight Kg. The Activity dispensed into a 10mL syringe using a NIST traceable Capintec CRC-25R Chamber and a cross calibrated capintec CRC-15R to measure activity in the syringe immediately before and after administration Results: The patients weight range from 121Ib to 235lb and doses ranging 74.25 µCi to 144.2 µCi. The deviation of dispensed dose vs Prescribed dose average +2.1% with a range of −1.1% to +5.7%. The Dose measured before administration ranges 79.3 µCi to 154.9 µCi. Deviation from the dispensed dose was show to average +2.9% with a range of −0.8% to +7.3%. The average residual dose post injection was 2.5 µCi or 2.2% of the pre injection activity. Ranging from 0.9 µCi to 6.2 µCi, 0.7% to 5.4% respectively. Subtracting the residual activity from that measured activity before injection and comparing it to prescription dose was shown to have an average variation of +2.7% with a range of −0.8% to 7.4%. Conclusion: The case resulted in the 6.2 µCi maximum residual dose had two syringes. A small, 82.8 µCi activity, case resulted in the 7.4% maximum variation in measures less residual verses prescription dose. The average +2.1 % dispenses activity of Ra 223 over the prescription dosage was seen to counteract the average 2.2% residual dosage found to remain in the syringe.

  7. The influence of glass composition on crystalline phase stability in glass-ceramic wasteforms

    International Nuclear Information System (INIS)

    Maddrell, Ewan; Thornber, Stephanie; Hyatt, Neil C.

    2015-01-01

    Highlights: • Crystalline phase formation shown to depend on glass matrix composition. • Zirconolite forms as the sole crystalline phase only for most aluminous glasses. • Thermodynamics indicate that low silica activity glasses stabilise zirconolite. - Abstract: Zirconolite glass-ceramic wasteforms were prepared using a suite of Na 2 O–Al 2 O 3 –B 2 O 3 –SiO 2 glass matrices with variable Al:B ratios. Zirconolite was the dominant crystalline phase only for the most alumina rich glass compositions. As the Al:B ratio decreased zirconolite was replaced by sphene, zircon and rutile. Thermodynamic data were used to calculate a silica activity in the glass melt below which zirconolite is the favoured crystalline phase. The concept of the crystalline reference state of glass melts is then utilised to provide a physical basis for why silica activity varies with the Al:B ratio

  8. Effect of relative nanohole position on colour purity of ultrathin plasmonic subtractive colour filters

    International Nuclear Information System (INIS)

    Sun, L B; Hu, X L; Zhang, D X; Zeng, Beibei; Wang, L S; Yang, S M; Tai, R Z; Fecht, H J; Jiang, J Z

    2015-01-01

    Plasmonic subtractive color filters through patterning periodic nanostructures on ultrathin Ag films deposited on a glass substrate, exhibiting good durability, simple fabrication, and flexible color tunability, have attracted considerable attention due to their tremendous potential applications. While previous studies have mainly focused on their extraordinary physical mechanisms, color purity, which is another key parameter for high quality imaging applications, has been much less investigated. In this work, we demonstrate that the relative position of nanoholes patterned on ultrathin Ag films can largely affect the color purity of plasmonic subtractive color filters. The calculated results agree reasonably well with the experimental data, revealing that the purity of subtractive colors can be improved by changing the nanohole arrays from square lattice to triangular lattice without reducing transmission at visible frequencies. In addition, underlying mechanisms are clarified by systematically analyzing the dominant valley in transmission spectra. (paper)

  9. Particle Kalman Filtering: A Nonlinear Bayesian Framework for Ensemble Kalman Filters*

    KAUST Repository

    Hoteit, Ibrahim

    2012-02-01

    This paper investigates an approximation scheme of the optimal nonlinear Bayesian filter based on the Gaussian mixture representation of the state probability distribution function. The resulting filter is similar to the particle filter, but is different from it in that the standard weight-type correction in the particle filter is complemented by the Kalman-type correction with the associated covariance matrices in the Gaussian mixture. The authors show that this filter is an algorithm in between the Kalman filter and the particle filter, and therefore is referred to as the particle Kalman filter (PKF). In the PKF, the solution of a nonlinear filtering problem is expressed as the weighted average of an “ensemble of Kalman filters” operating in parallel. Running an ensemble of Kalman filters is, however, computationally prohibitive for realistic atmospheric and oceanic data assimilation problems. For this reason, the authors consider the construction of the PKF through an “ensemble” of ensemble Kalman filters (EnKFs) instead, and call the implementation the particle EnKF (PEnKF). It is shown that different types of the EnKFs can be considered as special cases of the PEnKF. Similar to the situation in the particle filter, the authors also introduce a resampling step to the PEnKF in order to reduce the risk of weights collapse and improve the performance of the filter. Numerical experiments with the strongly nonlinear Lorenz-96 model are presented and discussed.

  10. Fusibility of medical glass in hospital waste incineration: Effect of glass components

    International Nuclear Information System (INIS)

    Jiang, X.G.; An, C.G.; Li, C.Y.; Fei, Z.W.; Jin, Y.Q.; Yan, J.H.

    2009-01-01

    Medical glass, which is the principal incombustible component in hospital wastes, has a bad influence on combustion. In a rotary kiln incinerator, medical glass melts and turns into slag, possibly adhering to the inner wall. Prediction of the melting characteristics of medical glass hence is important for preventing slagging. The effect of various glass components on fusibility has been investigated experimentally; that of Na 2 O is the most marked. The softening temperature and flow temperature decrease 19.8 o C and 34.0 o C, respectively, with a rise of Na 2 O content in the Basic Content (standard composition of medical glass) of 1%. Correlations between fusion temperatures and glass components have been investigated; predictive functions of four characteristic melting temperatures have been obtained by simplifying the multi-variant series and were verified by testing glass samples. Relative errors of fusion temperatures (computed vs. measured) are mostly less than 5%.

  11. Rectifier Filters

    Directory of Open Access Journals (Sweden)

    Y. A. Bladyko

    2010-01-01

    Full Text Available The paper contains definition of a smoothing factor which is suitable for any rectifier filter. The formulae of complex smoothing factors have been developed for simple and complex passive filters. The paper shows conditions for application of calculation formulae and filters

  12. Thermal Conductivity of Foam Glass

    DEFF Research Database (Denmark)

    Petersen, Rasmus Rosenlund; König, Jakob; Yue, Yuanzheng

    Due to the increased focus on energy savings and waste recycling foam glass materials have gained increased attention. The production process of foam glass is a potential low-cost recycle option for challenging waste, e.g. CRT glass and industrial waste (fly ash and slags). Foam glass is used...... as thermal insulating material in building and chemical industry. The large volume of gas (porosity 90 – 95%) is the main reason of the low thermal conductivity of the foam glass. If gases with lower thermal conductivity compared to air are entrapped in the glass melt, the derived foam glass will contain...... only closed pores and its overall thermal conductivity will be much lower than that of the foam glass with open pores. In this work we have prepared foam glass using different types of recycled glasses and different kinds of foaming agents. This enabled the formation of foam glasses having gas cells...

  13. Joints in Tempered Glass Using Glass Dowel Discs

    DEFF Research Database (Denmark)

    Nielsen, Jens Henrik; Poulsen, Peter Noe

    One of the major reasons for using glass in structures is its transparency; however, traditional mechanical joints such as friction joints and steel dowel pinned connections are compromising the transparency. The present paper describes a novel joint which is practically maintaining the complete...... transparency of the glass. This is achieved by using a dowel disc made entirely of tempered glass. The concept of the joint is proved by pilot tests and numerical models. From the work it is seen that the load-carrying capacity of such a connection is similar to what is found for traditionally in-plane loaded...

  14. A simple method for tuning the glass transition process in inorganic phosphate glasses

    OpenAIRE

    Fulchiron, Ren?; Belyamani, Imane; Otaigbe, Joshua U.; Bounor-Legar?, V?ronique

    2015-01-01

    The physical modification of glass transition temperature (Tg ) and properties of materials via blending is a common practice in industry and academia and has a large economic advantage. In this context, simple production of hitherto unattainable new inorganic glass blends from already existing glass compositions via blending raises much hope with the potential to provide new glasses with new and improved properties, that cannot be achieved with classical glass synthesis, for a plethora of ap...

  15. Copper oxide content dependence of crystallization behavior, glass forming ability, glass stability and fragility of lithium borate glasses

    International Nuclear Information System (INIS)

    Soliman, A.A.; Kashif, I.

    2010-01-01

    Differential thermal analysis (DTA) and X-ray diffraction (XRD) have been employed to investigate the copper oxide content dependence of the glass transition temperatures data, activation energy for the glass transition E t , glass stability GS, fragility index Fi, the glass-forming ability (GFA) and crystallization behavior of {(100-x) mol% Li 2 B 4 O 7 -x mol% CuO} glass samples, where x=0-40 mol% CuO. From the dependence of the glass transition temperature T g on the heating rate β, the fragility, F i , and the activation energy, E t , have been calculated. It is seen that F i and E t are attained their minimum values at 0 x -T g , SCL region and the GS. The GFA has been investigated on the basis of Hruby parameter K H , which is a strong indicator of GFA, and the relaxation time. Results of GFA are in good agreement with the fragility index, F i , calculations indicating that {90Li 2 B 4 O 7 .10CuO} is the best glass former. The stronger glass forming ability has decreasing the fragility index. XRD result indicates that no fully amorphous samples but a mixture of crystalline and amorphous phases are formed in the samples containing x>25 mol% CuO and below it composed of glassy phase. Increasing the CuO content above 25 mol% helps the crystallization process, and thus promotes a distinct SCL region. XRD suggests the presence of micro-crystallites of remaining residual amorphous matrix by increasing the CuO content.

  16. Printing and Curing of Conductive Ink Track on Fabric using Syringe Deposition System with DLP Projector and Hot Plate

    Directory of Open Access Journals (Sweden)

    Khirotdin Rd. Khairilhijra

    2017-01-01

    Full Text Available Printing is a technique to transfer ink onto substrates to create pattern and syringe deposition system has shown some great potential in printing due to its ability to produce filamentary bead tracks which is important concerning conductivity and easily adopted on conformal surfaces which could not be realized by conventional technique. Fabrics with integrated electrical features able to create intelligent articles and may potentially open up new perspective areas of application in textile printing. However, the applicability of this technique on fabrics remains unknown which the ink used has to meet certain requirements including high electrical conductivity, resistance to oxidation, dry out without clogging, good adhesion with suitable viscosity and surface tension. Thus, there is a need to do this study which is to determine the feasibility of syringe deposition system to print a conductive ink tracks using silver epoxy-based conductive ink on fabric substrate via lycra material. This study is also aim to investigate the feasibility of using DLP projector with hot plate as another source of heat to be used in curing the ink tracks on fabric. The effect of printing and curing parameters to the characteristics and conductivity of the ink track is investigated. Several mechanical and electrical tests were also administered to determine the cure, hardness, adhesion and resistance level of the ink tracks. The results obtained were as expected which higher printing speed and lower deposition height used, a narrower and thinner ink tracks were produced. Sample with 4 mm/s of printing speed and deposition height of 1 mm resulted in dimension closer to the targeted dimension. The longer curing time and higher temperature used, a lower resistance is produced. The lowest resistance achieved is 0.9 Ω cured at 150°C for 60 minutes. The conductivity of the ink track was affected by curing process and cross-sectional area of the ink track. It is proven

  17. Glass sample preparation and performance investigations. [solar x-ray imager

    Science.gov (United States)

    Johnson, R. Barry

    1992-01-01

    This final report details the work performed under this delivery order from April 1991 through April 1992. The currently available capabilities for integrated optical performance modeling at MSFC for large and complex systems such as AXAF were investigated. The Integrated Structural Modeling (ISM) program developed by Boeing for the U.S. Air Force was obtained and installed on two DECstations 5000 at MSFC. The structural, thermal and optical analysis programs available in ISM were evaluated. As part of the optomechanical engineering activities, technical support was provided in the design of support structure, mirror assembly, filter wheel assembly and material selection for the Solar X-ray Imager (SXI) program. As part of the fabrication activities, a large number of zerodur glass samples were prepared in different sizes and shapes for acid etching, coating and polishing experiments to characterize the subsurface damage and stresses produced by the grinding and polishing operations. Various optical components for AXAF video microscope and the x-ray test facility were also fabricated. A number of glass fabrication and test instruments such as a scatter plate interferometer, a gravity feed saw and some phenolic cutting blades were fabricated, integrated and tested.

  18. Syringeal specialization of frequency control during song production in the Bengalese finch (Lonchura striata domestica.

    Directory of Open Access Journals (Sweden)

    Kristen R Secora

    Full Text Available Singing in songbirds is a complex, learned behavior which shares many parallels with human speech. The avian vocal organ (syrinx has two potential sound sources, and each sound generator is under unilateral, ipsilateral neural control. Different songbird species vary in their use of bilateral or unilateral phonation (lateralized sound production and rapid switching between left and right sound generation (interhemispheric switching of motor control. Bengalese finches (Lonchura striata domestica have received considerable attention, because they rapidly modify their song in response to manipulations of auditory feedback. However, how the left and right sides of the syrinx contribute to acoustic control of song has not been studied.Three manipulations of lateralized syringeal control of sound production were conducted. First, unilateral syringeal muscular control was eliminated by resection of the left or right tracheosyringeal portion of the hypoglossal nerve, which provides neuromuscular innervation of the syrinx. Spectral and temporal features of song were compared before and after lateralized nerve injury. In a second experiment, either the left or right sound source was devoiced to confirm the role of each sound generator in the control of acoustic phonology. Third, air pressure was recorded before and after unilateral denervation to enable quantification of acoustic change within individual syllables following lateralized nerve resection.These experiments demonstrate that the left sound source produces louder, higher frequency, lower entropy sounds, and the right sound generator produces lower amplitude, lower frequency, higher entropy sounds. The bilateral division of labor is complex and the frequency specialization is the opposite pattern observed in most songbirds. Further, there is evidence for rapid interhemispheric switching during song production. Lateralized control of song production in Bengalese finches may enhance acoustic

  19. Corrosion testing of a plutonium-loaded lanthanide borosilicate glass made with Frit B.

    Energy Technology Data Exchange (ETDEWEB)

    Ebert, W. L.; Chemical Engineering

    2006-09-30

    directly. The releases of Gd, Hf, and Pu from the glass were also measured. The release of Pu was significantly less than Si at all temperatures and pH values (on a normalized basis). More Gd than Pu or Hf was released from the glass in acidic solutions, but more Pu than Gd or Hf was released in alkaline solutions. Almost all of the released Gd remained in solution in tests conducted in Teflon vessels, whereas about half of the released Pu and Hf became fixed to the Teflon. In tests conducted in Type 304L stainless steel vessels, most of the released Gd, Hf, and Pu became fixed to the steel. The aqueous concentrations of Gd, Hf, and Pu decreased from about 2 x 10{sup -5}, 2 x 10{sup -8}, and 1 x 10{sup -7} M in tests solutions near pH 3.7 to about 1 x 10{sup -9}, 8 x 10{sup -10}, and 1 x 10{sup -8} M in test solutions near pH 10.8, respectively, in the 90 C tests in Teflon vessels (the solutions were not filtered prior to analysis). Vapor hydration tests (VHTs) were conducted at 120 and 200 C with Pu LaBS-B glass and SRL 418 glass, which was made to represent the HLW glass that will be used to macro-encapsulate LaBS glass within the waste form. Some VHTs were conducted with specimens of Pu LaBS-B and SRL 418 glasses that were in contact to study the effect of the solution generated as HLW glass dissolves on the corrosion behavior of Pu LaBS-B glass. Other VHTs were conducted in which the glasses were not in contact. The Pu LaBS-B glass is more durable than the HLW glass under these accelerating test conditions, even when the glasses are in contact. The presence of the SRL 418 glass did not promote the dissolution of the Pu LaBS-B glass significantly. However, Gd, Hf, and Pu were detected in alteration phases formed on the Pu LaBS-B glass surface and in (or on) phases formed by SRL 418 glass degradation, such as analcime. This indicates that Gd, Hf, and Pu were transported from the LaBS glass, through the water film formed on the specimens, and to the SRL 418 glass during

  20. [Quantitative determination of glass content in monazite glass-ceramics by IR technique].

    Science.gov (United States)

    He, Yong; Zhang, Bao-min

    2003-04-01

    Monazite glass-ceramics consist of both monazite and metaphoshate glass phases. The absorption bands of both phases do not overlap each other, and the absorption intensities of bands 1,275 and 616 cm-1 vary with the glass contents. The correlation coefficient between logarithmic absorbance ratio of the two bands and glass contents was r = 0.9975 and its regression equation was y = 48.356 + 25.93x. The absorbance ratio of bands 952 and 616 cm-1 also varied with different ratios of Ce2O3/La2O3 in synthetic monazites, with r = 0.9917 and a regression equation y = 0.2211 exp (0.0221x). High correlation coefficients show that the IR technique could find new application in the quantitative analysis of glass content in phosphate glass-ceramics.

  1. Lead recovery and high silica glass powder synthesis from waste CRT funnel glasses through carbon thermal reduction enhanced glass phase separation process

    Energy Technology Data Exchange (ETDEWEB)

    Xing, Mingfei [Henan Key Laboratory Cultivation Base of Mine Environmental Protection and Ecological Remediation, Henan Polytechnic University, Jiaozuo 454000 Henan China (China); Institute of Resource and Environment, Henan Polytechnic University, Jiaozuo 454000 Henan China (China); Fu, Zegang [Institute of Resource and Environment, Henan Polytechnic University, Jiaozuo 454000 Henan China (China); Wang, Yaping, E-mail: wangyp326@163.com [School of Surveying and Land Information Engineering, Henan Polytechnic University, Jiaozuo 454000, Henan China (China); Wang, Jingyu [Institute of Resource and Environment, Henan Polytechnic University, Jiaozuo 454000 Henan China (China); Zhang, Zhiyuan [Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085 (China)

    2017-01-15

    Highlights: • CRT funnel glass was remelted with B{sub 2}O{sub 3} in reducing atmosphere. • A part of PbO was reduced into Pb and detached from the glass phase. • The rest of PbO and other metal oxides were mainly concentrated in the B{sub 2}O{sub 3} phase. • PbO enriched in the interconnected B{sub 2}O{sub 3} phase can be completely leached out by HNO{sub 3}. • High silica glass powder(SiO{sub 2} purity >95%) was obtained after the leaching process. - Abstract: In this study, a novel process for the removal of toxic lead from the CRT funnel glass and synchronous preparation of high silica glass powder was developed by a carbon-thermal reduction enhanced glass phase separation process. CRT funnel glass was remelted with B{sub 2}O{sub 3} in reducing atmosphere. In the thermal process, a part of PbO contained in the funnel glass was reduced into metallic Pb and detached from the glass phase. The rest of PbO and other metal oxides (including Na{sub 2}O, K{sub 2}O, Al{sub 2}O{sub 3,} BaO and CaO) were mainly concentrated in the boric oxide phase. The metallic Pb phase and boric oxide phase were completely leached out by 5 mol/L HNO{sub 3}. The lead removal rate was 99.80% and high silica glass powder (SiO{sub 2} purity >95 wt%) was obtained by setting the temperature, B{sub 2}O{sub 3} added amount and holding time at 1000 °C, 20% and 30 mins, respectively. The prepared high silicate glass powders can be used as catalyst carrier, semipermeable membranes, adsorbents or be remelted into high silicate glass as an ideal substitute for quartz glass. Thus this study proposed an eco-friendly and economical process for recycling Pb-rich electronic glass waste.

  2. The behavior of silicon and boron in the surface of corroded nuclear waste glasses: an EFTEM study

    International Nuclear Information System (INIS)

    Buck, E. C.; Smith, K. L.; Blackford, M. G.

    1999-01-01

    Using electron energy-loss filtered transmission electron microscopy (EFTEM), we have observed the formation of silicon-rich zones on the corroded surface of a West Valley (WV6) glass. This layer is approximately 100-200 nm thick and is directly underneath a precipitated smectite clay layer. Under conventional (C)TEM illumination, this layer is invisible; indeed, more commonly used analytical techniques, such as x-ray energy dispersive spectroscopy (EDS), have failed to describe fully the localized changes in the boron and silicon contents across this region. Similar silicon-rich and boron-depleted zones were not found on corroded Savannah River Laboratory (SRL) borosilicate glasses, including SRL-EA and SRL-51, although they possessed similar-looking clay layers. This study demonstrates a new tool for examining the corroded surfaces of materials

  3. Glass enamel and glass-ceramic coatings for chemical apparatus

    International Nuclear Information System (INIS)

    Es'kov, A.S.; Oleinik, M.I.; Shabrova, E.A.

    1984-01-01

    Among the known anticorrosion coatings used in chemical engineering, glass enamel base coatings are distinguished by such advantages as a high degree of continuity and chemical resistance. The paper describes basic principles for the creation of acid and alkali resistant glass enamel and ceramic coatings for chemical apparatus. As the result of investgations, glass enamel coatings with increased electrical conductivity and also experimental production compositions of chemical, temperature and radiation resistant coatings for protection of chemical equipment of 12Kh18N10T stainless steel have been developed. The coatings have successfully passed testing under service conditions. A new type of coating is short-term glass enamel, which may be recommended for use in chemical machinery manufacturing and other branches of industry in oxidation-free heating and forming of stainless steels

  4. Isotope effect in glass-transition temperature and ionic conductivity of lithium-borate glasses

    International Nuclear Information System (INIS)

    Nagasaki, Takanori; Morishima, Ryuta; Matsui, Tsuneo

    2002-01-01

    The glass-transition temperature and the electrical conductivity of lithium borate (0.33Li 2 O-0.67B 2 O 3 ) glasses with various isotopic compositions were determined by differential thermal analysis and by impedance spectroscopy, respectively. The obtained glass-transition temperature as well as the vibrational frequency of B-O network structure was independent of lithium isotopic composition. This result indicates that lithium ions, which exist as network modifier, only weakly interact with B-O network structure. In addition, the glass-transition temperature increased with 10 B content although the reason has not been understood. The electrical conductivity, on the other hand, increased with 6 Li content. The ratio of the conductivity of 6 Li glass to that of 7 Li glass was found to be 2, being larger than the value (7/6) 1/2 calculated with the simple classical diffusion theory. This strong mass dependence could be explained by the dynamic structure model, which assumes local structural relaxation even far below the glass-transition temperature. Besides, the conductivity appeared to increase with the glass-transition temperature. Possible correlations between the glass-transition temperature and the electrical conductivity were discussed. (author)

  5. Comment on 'Spherical 2+p spin-glass model: An analytically solvable model with a glass-to-glass transition'

    International Nuclear Information System (INIS)

    Krakoviack, V.

    2007-01-01

    Guided by old results on simple mode-coupling models displaying glass-glass transitions, we demonstrate, through a crude analysis of the solution with one step of replica symmetry breaking (1RSB) derived by Crisanti and Leuzzi for the spherical s+p mean-field spin glass [Phys. Rev. B 73, 014412 (2006)], that the phase behavior of these systems is not yet fully understood when s and p are well separated. First, there seems to be a possibility of glass-glass transition scenarios in these systems. Second, we find clear indications that the 1RSB solution cannot be correct in the full glassy phase. Therefore, while the proposed analysis is clearly naive and probably inexact, it definitely calls for a reassessment of the physics of these systems, with the promise of potentially interesting developments in the theory of disordered and complex systems

  6. Retina-Inspired Filter.

    Science.gov (United States)

    Doutsi, Effrosyni; Fillatre, Lionel; Antonini, Marc; Gaulmin, Julien

    2018-07-01

    This paper introduces a novel filter, which is inspired by the human retina. The human retina consists of three different layers: the Outer Plexiform Layer (OPL), the inner plexiform layer, and the ganglionic layer. Our inspiration is the linear transform which takes place in the OPL and has been mathematically described by the neuroscientific model "virtual retina." This model is the cornerstone to derive the non-separable spatio-temporal OPL retina-inspired filter, briefly renamed retina-inspired filter, studied in this paper. This filter is connected to the dynamic behavior of the retina, which enables the retina to increase the sharpness of the visual stimulus during filtering before its transmission to the brain. We establish that this retina-inspired transform forms a group of spatio-temporal Weighted Difference of Gaussian (WDoG) filters when it is applied to a still image visible for a given time. We analyze the spatial frequency bandwidth of the retina-inspired filter with respect to time. It is shown that the WDoG spectrum varies from a lowpass filter to a bandpass filter. Therefore, while time increases, the retina-inspired filter enables to extract different kinds of information from the input image. Finally, we discuss the benefits of using the retina-inspired filter in image processing applications such as edge detection and compression.

  7. Lead-iron phosophate glass

    International Nuclear Information System (INIS)

    Sales, B.C.; Boatner, L.A.

    1988-01-01

    The lead-iron phosphate nuclear waste glasses (LIPNWG) are the subject of the present chapter. They were discovered in 1984 while the authors were attempting to find a sintering aid for certain types of crystalline monazite ceramic high-level nuclear waste forms. In the present chapter, the term waste glass is synonymous with nuclear waste glass (NWG), and the acronym LIP is often used for lead-iron phosphate. Lead-iron phosphate glasses, like many of the previously studied phosphate glasses, are corrosion resistant in aqueous solutions at temperatures below 100 degrees C, and they can be melted and poured at temperatures that are relatively low in comparison with the processing temperatures required for current silicate glass compositions. Unlike the phosphate glasses investigated previously, however, LIPNWGs do not suffer from alteration due to devitrification during realistic and readily, achievable cooling periods. Additionally, lead-iron phosphate glass melts are not nearly as corrosive as the sodium phosphate melts investigated during the 1960s; and, therefore, they can be melted and processed using crucibles made from a variety of materials

  8. Radioresistance of inorganic glasses

    International Nuclear Information System (INIS)

    Vorob'ev, A.A.; Zavadovskaya, E.K.; Fedorov, B.V.; Starodubtsev, V.A.

    1977-01-01

    Regularities are considered in the variation of properties of glass due to irradiations. On the basis of previous theoretical statements and experimental investigations, it is inferred that the irradiation resistance of glasses of the same type, synthesis conditions, content of impurities and amount of imperfections, is a function of the ''element-oxygen'' bond energy. The irradiation resistance depends on the number and the nature of glass structure imperfections. The averaged level of bonding forces is indicative of the glass formation temperature; the imperfections in glasses are formed in structure elements whose amount predominates as compared to the others. Electric charges which accumulate on the crack surface tend to increase its size, thus lessening even further the electric strength of the dielectric. The greater the irradiation time, the greater the number of irradiation imperfections causing a drop in the electric strength of glass. When choosing a glass for service in a radiation field, it is necessary to select those of a highest temperature of glass formation and with a least amount of imperfections

  9. Braile vena cava filter and greenfield filter in terms of centralization.

    Science.gov (United States)

    de Godoy, José Maria Pereira; Menezes da Silva, Adinaldo A; Reis, Luis Fernando; Miquelin, Daniel; Torati, José Luis Simon

    2013-01-01

    The aim of this study was to evaluate complications experienced during implantation of the Braile Vena Cava filter (VCF) and the efficacy of the centralization mechanism of the filter. This retrospective cohort study evaluated all Braile Biomédica VCFs implanted from 2004 to 2009 in Hospital de Base Medicine School in São José do Rio Preto, Brazil. Of particular concern was the filter's symmetry during implantation and complications experienced during the procedure. All the angiographic examinations performed during the implantation of the filters were analyzed in respect to the following parameters: migration of the filter, non-opening or difficulties in the implantation and centralization of the filter. A total of 112 Braile CVFs were implanted and there were no reports of filter opening difficulties or in respect to migration. Asymmetry was observed in 1/112 (0.9%) cases. A statistically significant difference was seen on comparing historical data on decentralization of the Greenfield filter with the data of this study. The Braile Biomédico filter is an evolution of the Greenfield filter providing improved embolus capture and better implantation symmetry.

  10. Electrical properties of phosphate glasses

    International Nuclear Information System (INIS)

    Mogus-Milankovic, A; Santic, A; Reis, S T; Day, D E

    2009-01-01

    Investigation of the electrical properties of phosphate glasses where transition metal oxide such as iron oxide is the network former and network modifier is presented. Phosphate glasses containing iron are electronically conducting glasses where the polaronic conduction is due to the electron hopping from low to high iron valence state. The identification of structural defects caused by ion/polaron migration, the analysis of dipolar states and electrical conductivity in iron phosphate glasses containing various alkali and mixed alkali ions was performed on the basis of the impedance spectroscopy (IS). The changes in electrical conductivity from as-quenched phosphate glass to fully crystallized glass (glass-ceramics) by IS are analyzed. A change in the characteristic features of IS follows the changes in glass and crystallized glass network. Using IS, the contribution of glass matrix, crystallized grains and grain boundary to the total electrical conductivity for iron phosphate glasses was analyzed. It was shown that decrease in conductivity is caused by discontinuities in the conduction pathways as a result of the disruption of crystalline network where two or more crystalline phases are formed. Also, phosphate-based glasses offer a unique range of biomaterials, as they form direct chemical bonding with hard/soft tissue. The surface charges of bioactive glasses are recognized to be the most important factors in determining biological responses. The improved bioactivity of the bioactive glasses as a result of the effects of the surface charges generated by electrical polarization is discussed.

  11. Modelling of the glass fiber length and the glass fiber length distribution in the compounding of short glass fiber-reinforced thermoplastics

    Science.gov (United States)

    Kloke, P.; Herken, T.; Schöppner, V.; Rudloff, J.; Kretschmer, K.; Heidemeyer, P.; Bastian, M.; Walther, Dridger, A.

    2014-05-01

    The use of short glass fiber-reinforced thermoplastics for the production of highly stressed parts in the plastics processing industry has experienced an enormous boom in the last few years. The reasons for this are primarily the improvements to the stiffness and strength properties brought about by fiber reinforcement. These positive characteristics of glass fiber-reinforced polymers are governed predominantly by the mean glass fiber length and the glass fiber length distribution. It is not enough to describe the properties of a plastics component solely as a function of the mean glass fiber length [1]. For this reason, a mathematical-physical model has been developed for describing the glass fiber length distribution in compounding. With this model, it is possible on the one hand to optimize processes for the production of short glass fiber-reinforced thermoplastics, and, on the other, to obtain information on the final distribution, on the basis of which much more detailed statements can be made about the subsequent properties of the molded part. Based on experimental tests, it was shown that this model is able to accurately describe the change in glass fiber length distribution in compounding.

  12. Evidence-based policy versus morality policy: the case of syringe access programs.

    Science.gov (United States)

    de Saxe Zerden, Lisa; O'Quinn, Erin; Davis, Corey

    2015-01-01

    Evidence-based practice (EBP) combines proven interventions with clinical experience, ethics, and client preferences to inform treatment and services. Although EBP is integrated into most aspects of social work and public health, at times EBP is at odds with social policy. In this article the authors explore the paradox of evidence-based policy using syringe access programs (SAP) as a case example, and review methods of bridging the gap between the emphasis on EBP and lack of evidence informing SAP policy. Analysis includes the overuse of morality policy and examines historical and current theories why this paradox exists. Action steps are highlighted for creating effective policy and opportunities for public health change. Strategies on reframing the problem and shifting target population focus to garner support for evidence-based policy change are included. This interdisciplinary understanding of the way in which these factors converge is a critical first step in moving beyond morality-based policy toward evidence-based policy.

  13. Structural Glass Beams with Embedded Glass Fibre Reinforcement

    NARCIS (Netherlands)

    Louter, P.C.; Leung, Calvin; Kolstein, M.H.; Vambersky, J.N.J.A.; Bos, Freek; Louter, Pieter Christiaan; Veer, Fred

    2010-01-01

    This paper investigates the possibilities of pultruded glass fibre rods as embedded reinforcement in SentryGlas (SG) laminated glass beams. To do so, a series of pullout tests, to investigate the bond strength of the rods to the laminate, and a series of beam tests, to investigate the post-breakage

  14. Radiotracer injections through microfilters

    International Nuclear Information System (INIS)

    Huber, H.; Maschek, G.; Pichler, R.; Giesen, I.; Hatzl-Griesenhofer, M.; Maschek, W.

    2002-01-01

    Full text: Problems with the injection of radiotracers ( 99m Tc-HAMS, 99m Tc-DPD) to infants when administered through polar-filter-protected venous pathways caused us to get a closer look of what happens to a tracer in such a system. We simulated injections of the tracers mainly used at our institution in an in-vitro array and measured full and empty tracer syringes, filters (0.2 μm micropores) and the post-filter receptacle of the radioactivity. We calculated the percentage of filter-trapped activity and of activity in the receptacle. For several tracers we repeated this process with a neutral filter of the same pore size to get a comparison between the behavior in polarized and electrically inert filters. In general injection of a soluble radiotracer through a polar filter system means a dose loss in the filter of about 10 %, up to the tracer molecule size of IgG-antibodies. Suspended tracers, which consist of comparatively large particles, like RES- or pulmonary perfusion markers, are blocked by the filter, as can be foreseen with a particle size of >> 0.2 μm. DMSA and DPD (a biphosphonate), although both being soluble and rather small molecules, were blocked by the polar filter to a high extent, and by the neutral filter to a much lower, almost neglectable degree. The conclusions are: if possible avoid any use of a filter in your tracer injection pathway. Never use a filter with bone scan or DMSA applications. When doing uptake calculations you have to add the filter counts to the empty syringe value in the formula. If you cannot avoid to inject the radiotracer through a filter you have to replace the filter afterwards and treat the used filter as radioactive waste. The polarity of the filter material might severely affect retention of radiotracer in the filter. (author)

  15. Glass Property Models and Constraints for Estimating the Glass to be Produced at Hanford by Implementing Current Advanced Glass Formulation Efforts

    Energy Technology Data Exchange (ETDEWEB)

    Vienna, John D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kim, Dong-Sang [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Skorski, Daniel C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Matyas, Josef [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2013-07-01

    Recent glass formulation and melter testing data have suggested that significant increases in waste loading in HLW and LAW glasses are possible over current system planning estimates. The data (although limited in some cases) were evaluated to determine a set of constraints and models that could be used to estimate the maximum loading of specific waste compositions in glass. It is recommended that these models and constraints be used to estimate the likely HLW and LAW glass volumes that would result if the current glass formulation studies are successfully completed. It is recognized that some of the models are preliminary in nature and will change in the coming years. Plus the models do not currently address the prediction uncertainties that would be needed before they could be used in plant operations. The models and constraints are only meant to give an indication of rough glass volumes and are not intended to be used in plant operation or waste form qualification activities. A current research program is in place to develop the data, models, and uncertainty descriptions for that purpose. A fundamental tenet underlying the research reported in this document is to try to be less conservative than previous studies when developing constraints for estimating the glass to be produced by implementing current advanced glass formulation efforts. The less conservative approach documented herein should allow for the estimate of glass masses that may be realized if the current efforts in advanced glass formulations are completed over the coming years and are as successful as early indications suggest they may be. Because of this approach there is an unquantifiable uncertainty in the ultimate glass volume projections due to model prediction uncertainties that has to be considered along with other system uncertainties such as waste compositions and amounts to be immobilized, split factors between LAW and HLW, etc.

  16. Fluoride glass fiber optics

    CERN Document Server

    Aggarwal, Ishwar D

    1991-01-01

    Fluoride Glass Fiber Optics reviews the fundamental aspects of fluoride glasses. This book is divided into nine chapters. Chapter 1 discusses the wide range of fluoride glasses with an emphasis on fluorozirconate-based compositions. The structure of simple fluoride systems, such as BaF2 binary glass is elaborated in Chapter 2. The third chapter covers the intrinsic transparency of fluoride glasses from the UV to the IR, with particular emphasis on the multiphonon edge and electronic edge. The next three chapters are devoted to ultra-low loss optical fibers, reviewing methods for purifying and

  17. Homogeneity of Inorganic Glasses

    DEFF Research Database (Denmark)

    Jensen, Martin; Zhang, L.; Keding, Ralf

    2011-01-01

    Homogeneity of glasses is a key factor determining their physical and chemical properties and overall quality. However, quantification of the homogeneity of a variety of glasses is still a challenge for glass scientists and technologists. Here, we show a simple approach by which the homogeneity...... of different glass products can be quantified and ranked. This approach is based on determination of both the optical intensity and dimension of the striations in glasses. These two characteristic values areobtained using the image processing method established recently. The logarithmic ratio between...

  18. Glass-Glass Transitions by Means of an Acceptor-Donor Percolating Electric-Dipole Network

    Science.gov (United States)

    Zhang, Le; Lou, Xiaojie; Wang, Dong; Zhou, Yan; Yang, Yang; Kuball, Martin; Carpenter, Michael A.; Ren, Xiaobing

    2017-11-01

    We report the ferroelectric glass-glass transitions in KN (K+/Nb5 +) -doped BaTiO3 ferroelectric ceramics, which have been proved by x-ray diffraction profile and Raman spectra data. The formation of glass-glass transitions can be attributed to the existence of cubic (C )-tetragonal (T )-orthorhombic (O )-rhombohedral (R ) ferroelectric transitions in short-range order. These abnormal glass-glass transitions can perform very small thermal hysteresis (approximately 1.0 K ) with a large dielectric constant (approximately 3000), small remanent polarization Pr , and relative high maximum polarization Pm remaining over a wide temperature range (220-350 K) under an electrical stimulus, indicating the potential applications in dielectric recoverable energy-storage devices with high thermal reliability. Further phase field simulations suggest that these glass-glass transitions are induced by the formation of a percolating electric defect-dipole network (PEDN). This proper PEDN breaks the long-range ordered ferroelectric domain pattern and results in the local phase transitions at the nanoscale. Our work may further stimulate the fundamental physical theory and accelerate the development of dielectric energy-storing devices.

  19. Apollo 12 ropy glasses revisited

    Science.gov (United States)

    Wentworth, S. J.; Mckay, D. S.; Lindstrom, D. J.; Basu, A.; Martinez, R. R.; Bogard, D. D.; Garrison, D. H.

    1994-01-01

    We analyzed ropy glasses from Apollo 12 soils 12032 and 12033 by a variety of techniques including SEM/EDX, electron microprobe analysis, INAA, and Ar-39-Ar-40 age dating. The ropy glasses have potassium rare earth elements phosphorous (KREEP)-like compositions different from those of local Apollo 12 mare soils; it is likely that the ropy glasses are of exotic origin. Mixing calculations indicate that the ropy glasses formed from a liquid enriched in KREEP and that the ropy glass liquid also contained a significant amount of mare material. The presence of solar Ar and a trace of regolith-derived glass within the ropy glasses are evidence that the ropy glasses contain a small regolith component. Anorthosite and crystalline breccia (KREEP) clasts occur in some ropy glasses. We also found within these glasses clasts of felsite (fine-grained granitic fragments) very similar in texture and composition to the larger Apollo 12 felsites, which have a Ar-39-Ar-40 degassing age of 800 +/- 15 Ma. Measurements of 39-Ar-40-Ar in 12032 ropy glass indicate that it was degassed at the same time as the large felsite although the ropy glass was not completely degassed. The ropy glasses and felsites, therefore, probably came from the same source. Most early investigators suggested that the Apollo 12 ropy glasses were part of the ejecta deposited at the Apollo 12 site from the Copernicus impact. Our new data reinforce this model. If these ropy glasses are from Copernicus, they provide new clues to the nature of the target material at the Copernicus site, a part of the Moon that has not been sampled directly.

  20. Balanced microwave filters

    CERN Document Server

    Hong, Jiasheng; Medina, Francisco; Martiacuten, Ferran

    2018-01-01

    This book presents and discusses strategies for the design and implementation of common-mode suppressed balanced microwave filters, including, narrowband, wideband, and ultra-wideband filters This book examines differential-mode, or balanced, microwave filters by discussing several implementations of practical realizations of these passive components. Topics covered include selective mode suppression, designs based on distributed and semi-lumped approaches, multilayer technologies, defect ground structures, coupled resonators, metamaterials, interference techniques, and substrate integrated waveguides, among others. Divided into five parts, Balanced Microwave Filters begins with an introduction that presents the fundamentals of balanced lines, circuits, and networks. Part 2 covers balanced transmission lines with common-mode noise suppression, including several types of common-mode filters and the application of such filters to enhance common-mode suppression in balanced bandpass filters. Next, Part 3 exa...

  1. Assessment of water/glass interactions in waste glass melter operation

    International Nuclear Information System (INIS)

    Postma, A.K.; Chapman, C.C.; Buelt, J.L.

    1980-04-01

    A study was made to assess the possibility of a vapor explosion in a liquid-fed glass melter and during off-standard conditions for other vitrification processes. The glass melter considered is one designed for the vitrification of high-level nuclear wastes and is comprised of a ceramic-lined cavity with electrodes for joule heating and processing equipment required to add feed and withdraw glass. Vapor explosions needed to be considered because experience in other industrial processes has shown that violent interactions can occur if a hot liquid is mixed with a cooler, vaporizable liquid. Available experimental evidence and theoretical analyses indicate that destructive glass/water interactions are low probability events, if they are possible at all. Under standard conditions, aspects of liquid-fed melter operation which work against explosive interactions include: (1) the aqueous feed is near its boiling point; (2) the feed contains high concentrations of suspended particles; (3) molten glass has high viscosity (greater than 20 poise); and (4) the glass solidifies before film boiling can collapse. While it was concluded that vapor explosions are not expected in a liquid-fed melter, available information does not allow them to be ruled out altogether. Several precautionary measures which are easily incorporated into melter operation procedures were identified and additional experiments were recommended

  2. Glass Glimpsed

    DEFF Research Database (Denmark)

    Lock, Charles

    2015-01-01

    Glass in poetry as it reflects the viewer and as its power of reflection are both reduced and enhanced by technology.......Glass in poetry as it reflects the viewer and as its power of reflection are both reduced and enhanced by technology....

  3. Backflushable filter insert

    International Nuclear Information System (INIS)

    Keith, R.C.; Vandenberg, T.; Randolph, M.C.; Lewis, T.B.; Gillis, P.J. Jr.

    1988-01-01

    Filter elements are mounted on a tube plate beneath an accumulator chamber whose wall is extended by skirt and flange to form a closure for the top of pressure vessel. The accumulator chamber is annular around a central pipe which serves as the outlet for filtered water passing from the filter elements. The chamber contains filtered compressed air from supply. Periodically the filtration of water is stopped and vessel is drained. Then a valve is opened, allowing the accumulated air to flow from chamber up a pipe and down pipe, pushing the filtered water from pipe back through the filter elements to clean them. The accumulator chamber is so proportioned, relative to the volume of the system communicating therewith during backflushing, that the equilibrium pressure during backflushing cannot exceed the pressure rating of the vessel. However a line monitors the pressure at the top of the vessel, and if it rises too far a bleed valve is automatically opened to depressurise the system. The chamber is intended to replace the lid of an existing vessel to convert a filter using filter aid to one using permanent filter elements. (author)

  4. Filter replacement lifetime prediction

    Science.gov (United States)

    Hamann, Hendrik F.; Klein, Levente I.; Manzer, Dennis G.; Marianno, Fernando J.

    2017-10-25

    Methods and systems for predicting a filter lifetime include building a filter effectiveness history based on contaminant sensor information associated with a filter; determining a rate of filter consumption with a processor based on the filter effectiveness history; and determining a remaining filter lifetime based on the determined rate of filter consumption. Methods and systems for increasing filter economy include measuring contaminants in an internal and an external environment; determining a cost of a corrosion rate increase if unfiltered external air intake is increased for cooling; determining a cost of increased air pressure to filter external air; and if the cost of filtering external air exceeds the cost of the corrosion rate increase, increasing an intake of unfiltered external air.

  5. Anti-clogging filter system

    Science.gov (United States)

    Brown, Erik P.

    2015-05-19

    An anti-clogging filter system for filtering a fluid containing large particles and small particles includes an enclosure with at least one individual elongated tubular filter element in the enclosure. The individual elongated tubular filter element has an internal passage, a closed end, an open end, and a filtering material in or on the individual elongated tubular filter element. The fluid travels through the open end of the elongated tubular element and through the internal passage and through the filtering material. An anti-clogging element is positioned on or adjacent the individual elongated tubular filter element and provides a fluid curtain that preferentially directs the larger particulates to one area of the filter material allowing the remainder of the filter material to remain more efficient.

  6. Baseline LAW Glass Formulation Testing

    International Nuclear Information System (INIS)

    Kruger, Albert A.; Mooers, Cavin; Bazemore, Gina; Pegg, Ian L.; Hight, Kenneth; Lai, Shan Tao; Buechele, Andrew; Rielley, Elizabeth; Gan, Hao; Muller, Isabelle S.; Cecil, Richard

    2013-01-01

    The major objective of the baseline glass formulation work was to develop and select glass formulations that are compliant with contractual and processing requirements for each of the LAW waste streams. Other objectives of the work included preparation and characterization of glasses with respect to the properties of interest, optimization of sulfate loading in the glasses, evaluation of ability to achieve waste loading limits, testing to demonstrate compatibility of glass melts with melter materials of construction, development of glass formulations to support ILAW qualification activities, and identification of glass formulation issues with respect to contract specifications and processing requirements

  7. The glass sphinx: a massive stacked glass structure

    NARCIS (Netherlands)

    Bos, F.P.; Heijden, van der T.; Schreurs, P.; Bos, F.; Louter, C.; Nijsse, R.; Veer, F.

    The refurbishment of the Meuse river boulevard in Venlo instigated Scheuten Glass to donate a giant-sized, 6 metre high version of the stacked glass statue the Sphinx, which had originally been made as a 80 cm sculpture to commemorate the city's 650th anniversary back in 1993. Many hurdles had to be

  8. Selection vector filter framework

    Science.gov (United States)

    Lukac, Rastislav; Plataniotis, Konstantinos N.; Smolka, Bogdan; Venetsanopoulos, Anastasios N.

    2003-10-01

    We provide a unified framework of nonlinear vector techniques outputting the lowest ranked vector. The proposed framework constitutes a generalized filter class for multichannel signal processing. A new class of nonlinear selection filters are based on the robust order-statistic theory and the minimization of the weighted distance function to other input samples. The proposed method can be designed to perform a variety of filtering operations including previously developed filtering techniques such as vector median, basic vector directional filter, directional distance filter, weighted vector median filters and weighted directional filters. A wide range of filtering operations is guaranteed by the filter structure with two independent weight vectors for angular and distance domains of the vector space. In order to adapt the filter parameters to varying signal and noise statistics, we provide also the generalized optimization algorithms taking the advantage of the weighted median filters and the relationship between standard median filter and vector median filter. Thus, we can deal with both statistical and deterministic aspects of the filter design process. It will be shown that the proposed method holds the required properties such as the capability of modelling the underlying system in the application at hand, the robustness with respect to errors in the model of underlying system, the availability of the training procedure and finally, the simplicity of filter representation, analysis, design and implementation. Simulation studies also indicate that the new filters are computationally attractive and have excellent performance in environments corrupted by bit errors and impulsive noise.

  9. Volatility and leachability of heavy metals and radionuclides in thermally treated HEPA filter media generated from nuclear facilities

    International Nuclear Information System (INIS)

    Yoon, In-Ho; Choi, Wang-Kyu; Lee, Suk-Chol; Min, Byung-Youn; Yang, Hee-Chul; Lee, Kune-Woo

    2012-01-01

    Highlights: ► Thermally treated HEPA filter media was transformed into glassy bulk materials. ► Main radionuclide and heavy metal were Cs-137 and Zn. ► Cs and Zn were transformed into stable form without volatilization and leaching. ► The proposed technique is simple and energy efficient procedure. - Abstract: The purpose of the present study was to apply thermal treatments to reduce the volume of HEPA filter media and to investigate the volatility and leachability of heavy metals and radionuclides during thermal treatment. HEPA filter media were transformed to glassy bulk material by thermal treatment at 900 °C for 2 h. The most abundant heavy metal in the HEPA filter media was Zn, followed by Sr, Pb and Cr, and the main radionuclide was Cs-137. The volatility tests showed that the heavy metals and radionuclides in radioactive HEPA filter media were not volatilized during the thermal treatment. PCT tests indicated that the leachability of heavy metals and radionuclides was relatively low compared to those of other glasses. XRD results showed that Zn and Cs reacted with HEPA filter media and were transformed into crystalline willemite (ZnO·SiO 2 ) and pollucite (Cs 2 OAl 2 O 3 4SiO 2 ), which are not volatile or leachable. The proposed technique for the volume reduction and transformation of radioactive HEPA filter media into glassy bulk material is a simple and energy efficient procedure without additives that can be performed at relatively low temperature compared with conventional vitrification process.

  10. Towards green buildings: Glass as a building element-the use and misuse in the gulf region

    Energy Technology Data Exchange (ETDEWEB)

    Aboulnaga, Mohsen M. [College of Design and Applied Arts, Dubai University College, Dubai P.O. Box 14143 (United Arab Emirates)

    2006-04-15

    The recent economic growth in the Gulf region notably in Dubai, United Arab Emirates (UAE) has led to a colossal number of buildings that has been constructed in the past 5 years. In the last decade, a total glazed building's facades became the icon of Dubai. This large area of glazing in each facade needs protection against overheating and sun glare in summer. According to leader in energy and environmental design (LEED) glass selection becomes a main element in this equation to contribute towards achieving a green building. The aim of this paper is to investigate the problems associated with misuse of glass, as a building element in UAE particularly in Dubai. Inadequate design with ill-selected glass/glazing type may lead not only to poor daylighting in building interiors but also contribute significantly to fatigue, insomnia, seasonal affective disorder (SAD) and above all increase CO{sub 2} emission. The purpose of the study is to specify the required improvements to permit natural, 'free' daylight to filter through the building facade into interior space, especially with the right type of glass. This paper examines the status of buildings in Dubai in terms of glass type, visible light transmittance, reflection (out/in) and relative heat gain. A quantitative analysis is conducted to assess the impact of glass on the building users' performance in terms of daylight environment. A recent built high-rise office building was selected in the investigation to asses whether selected glass provide the recommended daylight factor (DF) and daylight level (DL) according to IES standards. The results revealed that most the glass/glazing was misused in 70% of buildings in intermediate and low performance groups. The DF and DD in the selected office building were unexpectedly tremendous and found far beyond the recommended level due to the use of spectrally selective glazing (clear on both sides). [Author].

  11. Needle syringe programmes and opioid substitution therapy for preventing hepatitis C transmission in people who inject drugs

    Science.gov (United States)

    Platt, Lucy; Minozzi, Silvia; Reed, Jennifer; Vickerman, Peter; Hagan, Holly; French, Clare; Jordan, Ashly; Degenhardt, Louisa; Hope, Vivian; Hutchinson, Sharon; Maher, Lisa; Palmateer, Norah; Taylor, Avril; Bruneau, Julie; Hickman, Matthew

    2017-01-01

    Background Needle syringe programmes and opioid substitution therapy for preventing hepatitis C transmission in people who inject drugs Needle syringe programmes (NSP) and opioid substitution therapy (OST) are the primary interventions to reduce hepatitis C (HCV) transmission in people who inject drugs. There is good evidence for the effectiveness of NSP and OST in reducing injecting risk behaviour and increasing evidence for the effectiveness of OST and NSP in reducing HIV acquisition risk, but the evidence on the effectiveness of NSP and OST for preventing HCV acquisition is weak. Objectives To assess the effects of needle syringe programmes and opioid substitution therapy, alone or in combination, for preventing acquisition of HCV in people who inject drugs. Search methods We searched the Cochrane Drug and Alcohol Register, CENTRAL, the Cochrane Database of Systematic Reviews (CDSR), the Database of Abstracts of Reviews of Effects (DARE), the Health Technology Assessment Database (HTA), the NHS Economic Evaluation Database (NHSEED), MEDLINE, Embase, PsycINFO, Global Health, CINAHL, and the Web of Science up to 16 November 2015. We updated this search in March 2017, but we have not incorporated these results into the review yet. Where observational studies did not report any outcome measure, we asked authors to provide unpublished data. We searched publications of key international agencies and conference abstracts. We reviewed reference lists of all included articles and topic-related systematic reviews for eligible papers. Selection criteria We included prospective and retrospective cohort studies, cross-sectional surveys, case-control studies and randomised controlled trials that measured exposure to NSP and/or OST against no intervention or a reduced exposure and reported HCV incidence as an outcome in people who inject drugs. We defined interventions as current OST (within previous 6 months), lifetime use of OST and high NSP coverage (regular attendance at

  12. Internal Friction in L.A.S. Type Glass and Glass-Ceramics

    OpenAIRE

    Arnault , L.; RiviÈre , A.

    1996-01-01

    Internal friction measurements have been performed on glass and glass-ceramics of the Li2O-Al2O3-SiO2 type by isothermal mechanical spectroscopy. Experiments were carried out over a large frequency range (10-4Hz - 31.6 Hz) for various temperatures between 260K and 850K. For the glass, a relaxation peak is observed at low temperature (276K for 1Hz). This peak does not appear in the glass-ceramics ; however, for each of them, two other peaks were observed : the first one at about 343K (1Hz) and...

  13. Cosmos & Glass

    DEFF Research Database (Denmark)

    Beim, Anne

    1996-01-01

    The article unfolds the architectural visions of glass by Bruno Taut. It refers to inspirations by Paul Sheerbart and litterature and the Crystal Chain, also it analyses the tectonic univers that can be found in the glass pavillion for the Werkbund exposition in Cologne....

  14. Changing ventilation filters

    International Nuclear Information System (INIS)

    Hackney, S.

    1980-01-01

    A filter changing unit has a door which interlocks with the door of a filter chamber so as to prevent contamination of the outer surfaces of the doors by radioactive material collected on the filter element and a movable support which enables a filter chamber thereonto to be stored within the unit in such a way that the doors of the unit and the filter chamber can be replaced. The door pivots and interlocks with another door by means of a bolt, a seal around the periphery lip of the first door engages the periphery of the second door to seal the gap. A support pivots into a lower filter element storage position. Inspection windows and glove ports are provided. The unit is releasably connected to the filter chamber by bolts engaging in a flange provided around an opening. (author)

  15. Glasses and nuclear waste vitrification

    International Nuclear Information System (INIS)

    Ojovan, Michael I.

    2012-01-01

    Glass is an amorphous solid material which behaves like an isotropic crystal. Atomic structure of glass lacks long-range order but possesses short and most probably medium range order. Compared to crystalline materials of the same composition glasses are metastable materials however crystallisation processes are kinetically impeded within times which typically exceed the age of universe. The physical and chemical durability of glasses combined with their high tolerance to compositional changes makes glasses irreplaceable when hazardous waste needs immobilisation for safe long-term storage, transportation and consequent disposal. Immobilisation of radioactive waste in glassy materials using vitrification has been used successfully for several decades. Nuclear waste vitrification is attractive because of its flexibility, the large number of elements which can be incorporated in the glass, its high corrosion durability and the reduced volume of the resulting wasteform. Vitrification involves melting of waste materials with glass-forming additives so that the final vitreous product incorporates the waste contaminants in its macro- and micro-structure. Hazardous waste constituents are immobilised either by direct incorporation into the glass structure or by encapsulation when the final glassy material can be in form of a glass composite material. Both borosilicate and phosphate glasses are currently used to immobilise nuclear wastes. In addition to relatively homogeneous glasses novel glass composite materials are used to immobilise problematic waste streams. (author)

  16. Reinforced glass beams composed of annealed, heat-strengthened and fully tempered glass

    NARCIS (Netherlands)

    Louter, P.C.; Belis, J.L.I.F.; Bos, F.P.; Veer, F.A.

    Annealed, heat-strengthened and fully tempered SG-laminated reinforced glass beam specimens were subjected to four-point bending tests to investigate the effects of glass type on their structural response. During the test the beams showed linear elastic response until initial glass failure, followed

  17. Crystallization in high-level waste glass: A review of glass theory and noteworthy literature

    Energy Technology Data Exchange (ETDEWEB)

    Christian, J. H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-08-01

    There is a fundamental need to continue research aimed at understanding nepheline and spinel crystal formation in high-level waste (HLW) glass. Specifically, the formation of nepheline solids (K/NaAlSiO₄) during slow cooling of HLW glass can reduce the chemical durability of the glass, which can cause a decrease in the overall durability of the glass waste form. The accumulation of spinel solids ((Fe, Ni, Mn, Zn)(Fe,Cr)₂O₄), while not detrimental to glass durability, can cause an array of processing problems inside of HLW glass melters. In this review, the fundamental differences between glass and solid-crystals are explained using kinetic, thermodynamic, and viscosity arguments, and several highlights of glass-crystallization research, as it pertains to high-level waste vitrification, are described. In terms of mitigating spinel in the melter and both spinel and nepheline formation in the canister, the complexity of HLW glass and the intricate interplay between thermal, chemical, and kinetic factors further complicates this understanding. However, new experiments seeking to elucidate the contributing factors of crystal nucleation and growth in waste glass, and the compilation of data from older experiments, may go a long way towards helping to achieve higher waste loadings while developing more efficient processing strategies.

  18. Restorative Glass : Reversible, discreet restoration using structural glass components

    NARCIS (Netherlands)

    Oikonomopoulou, F.; Bristogianni, T.; Barou, L.; van Hees, R.P.J.; Nijsse, R.; Veer, F.A.; Henk, Schellen; van Schijndel, Jos

    2016-01-01

    The application of structural glass as the principal material in restoration and conservation practices is a distinguishable, yet discreet approach. The transparency of glass allows the simultaneous perception of the monument at both its original and present condition, preserving its historical and

  19. Cost and waste volume reduction in HEPA filter trains by effective pre-filtration

    International Nuclear Information System (INIS)

    Chadwick, Chris; Kaufman, Seth

    2006-01-01

    Data published elsewhere (Moore, et el 1992; Bergman et al 1997) suggests that the then costs of disposable type Glass Fibre HEPA filtration trains to the DOE was USD 55 million per year (based on an average usage of HEPA panels of 11,748 pieces per year between 1987 and 1990), USD 50 million of which was attributable to installation, testing, removal and disposal - although the life cycle costs are themselves based on estimates dating from 1987-1990. The same authors suggest that by 1995 the number of HEPA panels being used had dropped to an estimated 4000 pieces per year due to the ending of the Cold War. The yearly cost to the DOE of 4000 units per year was estimated to be USD 29.5 million using the same parameters that suggested the previously stated USD 55 million for the larger quantity. Within that cost estimate, USD 300 was the value given to the filter and USD 4,450 was given to peripheral activity per filter. Clearly, if the USD 4,450 component could be reduced, tremendous saving could result, in addition to a significant reduction in the legacy burden of waste volumes. This same cost is applied to both the 11,748 and 4000 usage figures. The work up to now has focussed on the development of a low cost, long life (cleanable) direct replacement of the traditional filter train, but this paper will review an alternative strategy, that of preventing the contaminating dust from reaching and blinding the HEPA filters, and thereby removing the need to replace them. What has become clear is that 'low cost' and 'stainless HEPA' are not compatible terms. The original Bergman et al work suggested that 1000 ft 3 /min stainless HEPAs could be commercially available for USD 5000 each after development (although the USD 70,000 development unit may be somewhat exaggerated - the authors have estimated that development units able to be retro-fitted into strengthened standard housings would be available for perhaps USD 30,000). The likely true cost of such an item produced

  20. Glass corrosion in natural environments

    Science.gov (United States)

    Thorpe, Arthur N.; Barkatt, Aaron

    1992-01-01

    Experiments carried out during the progress period are summarized. Experiments carried out involving glass samples exposed to solutions of Tris have shown the appearance of 'spikes' upon monitoring glass dissolution as a function of time. The periodic 'spikes' observed in Tris-based media were interpreted in terms of cracking due to excessive stress in the surface region of the glass. Studies of the interactions of silicate glasses with metal ions in buffered media were extended to systems containing Al. Caps buffer was used to establish the pH. The procedures used are described and the results are given. Preliminary studies were initiated as to the feasibility of adding a slowly dissolving solid compound of the additive to the glass-water system to maintain a supply of dissolved additive. It appears that several magnesium compounds have a suitable combination of solubility and affinity towards silicate glass surfaces to have a pronounced retarding effect on the extraction of uranium from the glass. These preliminary findings raise the possibility that introducing a magnesium source into geologic repositories for nuclear waste glass in the form of a sparingly soluble Mg-based backfill material may cause a substantial reduction in the extent of long-term glass corrosion. The studies described also provide mechanistic understanding of the roles of various metal solutes in the leachant. Such understanding forms the basis for developing long-term predictions of nuclear waste glass durability under repository conditions. From what is known about natural highly reduced glasses such as tektites, it is clear that iron is dissolved as ferrous iron with little or no ferric iron. The reducing conditions were high enough to cause metallic iron to exsolve out of the glass in the form of submicroscopic spherules. As the nuclear waste glass is much less reduced, a study was initiated on other natural glasses in addition to the nuclear waste glass. Extensive measurements were