Sample records for glass dosemeters

  1. Development trends of radiophotoluminescent glass dosemeter

    International Nuclear Information System (INIS)

    Ikegami, T.

    2004-01-01

    RPL glass dosemeter has been recently recognized to have a good performance as accumulation dosemeter and has been routinely used for personal dosimetry and environmental radiation monitoring. Furthermore, its applicable field is being extending to medical radiation measurement. The history of RPL glass dosemeter is very long. It was born in USA in 1950s and after that it was improved in Japan. And it was used as personal dosemeter in 1970s. But, in those days, RPL glass dosemeter was not suitable to low dose measurement due to some handling problems. So, its use had been reduced gradually. The author has broken through any past problems, by mainly realizing the pulsed UV excitation method. In this paper, the development history, principle and features, and the development good results of the pulsed UV excitation method are summarized, including the introduction of recent RPL glass dosimetry products. (author)

  2. Glass as a gamma ray dosemeter

    International Nuclear Information System (INIS)

    Sutrisno Puspodikoro.

    1978-01-01

    The advantages of glass as a γ-rays dosemeter are studied. Experiments have shown that ordinary microscope object glass can be used as a dosemeter, which dose range for linear response extends from about 10 4 -10 6 rads. Heat treatment of the irradiated samples accelerates the initial fading of coloration and stabilizes the residual optical density. On the other side cooling of them retards the initial fading. (author)

  3. Dosimertry characteristics and performance comparisons: Environmental radiophotoluminescent glass dosemeters versus thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Lee, J.H.; Lin, M.S.; Hsu, S.M.; Chen, I.J.; Chen, W.L.; Wang, C.F.

    2009-01-01

    This paper describes the dosimetry characteristic comparison of environmental radiophotoluminescent glass dosemeter (RPLGD) and thermoluminescent dosemeter (TLD) systems employed at the Institute of Nuclear Energy Research (INER, Taiwan). The luminescence centers of TLD disappeared by reading process, and repetition of measurement is impossible. RPLGDs can be repeatedly read and keep the luminescence centers for a long time. The RPLGD fading is about 1% within 30 days after being exposed to ionizing radiation. Environmental cumulative doses measured by a RPLGD and a TLD were compared at the same monitoring points of INER during two years. The sensitivity of TLD decreased with gradual loss due to fading at higher temperatures. The difference between results obtained by RPLGD and TLD is discussed mainly with respect to the dependence on the ambient temperature. In addition, this research also refers to the American National Standard Institute (ANSI) Draft Standard N13.29 (1996) to organize the environmental dosimetry performance tests of the INER's RPLGDs and the TLDs. The results mean that both kinds of dosemeters can meet the performance test criteria. An accreditation procedure for the institutes which provide the environmental dosimetry services in Taiwan was suggested based on the comparison results of these two dosimetry systems

  4. Development of confocal laser microscope system for examination of microscopic characteristics of radiophotoluminescence glass dosemeters

    International Nuclear Information System (INIS)

    Maki, D.; Ishii, T.; Sato, F.; Kato, Y.; Yamamoto, T.; Iida, T.

    2011-01-01

    A confocal laser microscope system was developed for the measurement of radiophotoluminescence (RPL) photons emitted from a minute alpha-ray-irradiated area in an RPL glass dosemeter. The system was composed mainly of an inverted-type microscope, an ultraviolet laser, an XY movable stage and photon-counting circuits. The photon-counting circuits were effective in the reduction of the background noise level in the measurement of RPL photons. The performance of this microscope system was examined by the observation of standard RPL glass samples irradiated using 241 Am alpha rays. The spatial resolution of this system was ∼3 μm, and with regard to the sensitivity of this system, a hit of more than four to five alpha rays in unit area produced enough amount of RPL photons to construct the image. (authors)

  5. Development of confocal laser microscope system for examination of microscopic characteristics of radiophotoluminescence glass dosemeters.

    Science.gov (United States)

    Maki, Daisuke; Ishii, Tetsuya; Sato, Fuminobu; Kato, Yushi; Yamamoto, Takayoshi; Iida, Toshiyuki

    2011-03-01

    A confocal laser microscope system was developed for the measurement of radiophotoluminescence (RPL) photons emitted from a minute alpha-ray-irradiated area in an RPL glass dosemeter. The system was composed mainly of an inverted-type microscope, an ultraviolet laser, an XY movable stage and photon-counting circuits. The photon-counting circuits were effective in the reduction of the background noise level in the measurement of RPL photons. The performance of this microscope system was examined by the observation of standard RPL glass samples irradiated using (241)Am alpha rays. The spatial resolution of this system was ∼ 3 μm, and with regard to the sensitivity of this system, a hit of more than four to five alpha rays in unit area produced enough amount of RPL photons to construct the image.

  6. Investigations of the luminescence of phosphate glasses with respect to their application as solid dosemeters

    International Nuclear Information System (INIS)

    Regulla, D.F.

    1977-03-01

    A comprehensive presentation of the luminescent properties of phosphate glass is worked out. The extensive investigations show an essential enlargement of the knowledge on the luminescence of phosphate glass existing hitherto. These results form the basis for a detailed discussion of the luminescence mechanism. By applying additional results of measurements concerning optical and paramagnetic absorption, enabling the access to the atomic effect, propositions were developed for models of absorption, excitation and luminous centers relevant for dosimetry for which Ag ++ was found to be the constituent determining the centers. The interpretation of the luminescence phenomena within the frame of these models leads to considerable corrections on the existing concepts. At the same time the comparability of Ag-doped phosphate glasses and alkali halogenides is shown with respect to their luminescence behaviour, and with it an argument for the existence of crystal-like short-order regions in the amorphous glass is provided. This result serves as a basis for a discussion of the centers in the band model. Further investigations dealt with the quantities of influence for the practical application of the dosemeter. By interpretation of these results explanations are given for the effect of irradiation and evaluation temperatures, of LET, the dose, and UV light on the measuring signal. The phenomenon of 'pre-dose', for which especially surface effects have been detected as cause, is discussed under the aspect of a boundary layer theory. (orig./HP) [de

  7. Passive dosemeter

    International Nuclear Information System (INIS)

    Hassib, G.; Piesch, E.

    1981-01-01

    The dosemeter will be used for the detection of radon and thoron as well as their daughter products. It consists of two chambers with nuclear trace or alpha detectors. Both chambers are connected with one another at their front sides with a filter arranged in between. One of the chambers has got lateral openings, it is used as a diffusion chamber. In the other chamber exclusively radon and thoron are detected. (DG) [de

  8. Application of radiophotoluminescence dosemeters for environmental monitoring

    International Nuclear Information System (INIS)

    Mihara, A.; Tamura, T.; Mochizuki, T.; Numakunai, T.; Yoshida, Y.; Ohi, Y.

    1993-01-01

    Feasibility study has been made on the radiofluorescence glass (RPL) dosemeters for environmental radiation monitoring. Main items in the laboratory tests are batch uniformities of pre-dose and sensitivity, build-up characteristics of RPL intensity, energy and angular responses, stabilities for RPL reading, anneal cycling and climatic conditional changes. We have determined self-irradiation dose and cosmic ray contribution. Radiation monitoring field test for the RPL dosemeters has been conducted in comparison with the present TLD systems. A procedure manual for the environmental monitoring by the use of RPL dosemeters is in preparation

  9. Silver-activated radiophotoluminescence dosemeter glass with high sensitivity and good corrosion resistance, method of production and applications

    International Nuclear Information System (INIS)

    Kaes, H.H.; Staaden, H.

    1976-01-01

    Hitherto known radiophotoluminescent dosimeter glasses have an interfering maximum of energy dependence in the γ-energy region of 40-60 KeV. The glas according to the invention does not have this disadvantage as the metaphophate group has been replaced by fluorine. The glass is melted from a mixture which besides a silver compound (AgPO 3 , AgNO 3 , Ag 2 CO 3 or LiAg[PO 3 ] 2 ) consists of at least one fluoride. Detailed examples clarify the method and give the limits of possible deviations in the composition. (UWI) [de

  10. Quality control for dosemeters

    International Nuclear Information System (INIS)

    Di Prinzio, R.

    1988-01-01

    Several tests and intercomparison of the secondary standard dosemeter calibration in Rio de Janeiro are described. Periodical tests, such as leakage current and the comparison between the secondary standard dosemeter in Rio de Janeiro e Sao Paulo are shown. (E.G.) [pt

  11. Electronic personal dosemeters

    International Nuclear Information System (INIS)

    Marshall, T.O.; Bartlett, D.T.; Burgess, P.H.; Cranston, C.S.; Higginbottom, D.J.; Sutton, K.W.

    1990-01-01

    Personal dosimetry services approved by their national authorities for category A workers, invariably use passive dosemeters incorporating photographic film or thermoluminescent detectors. However, the performance characteristics of electronic dosemeters has improved substantially over the past decade to such an extent that in the opening lecture of the Solid State Dosimetry Conference at Oxford in 1986 the development of an electronic 'smart card' based on a silicon detector was briefly discussed. This idea has been taken up and at least one development programme is in progress aimed at the production of an electronic dosemeter suitable for use as a legal device. The more important performance requirements of personal dosemeters for this purpose are discussed and the earlier electronic dosemeter designs and the latest devices under development to meet this specification are compared. (author)

  12. Acid dip for dosemeter

    International Nuclear Information System (INIS)

    Stewart, J.C.; McWhan, A.F.

    1982-01-01

    Background signal in a PTFE based dosemeter caused by impurities in the PTFE and in the active component such as lithium fluoride is substantially reduced by treating the dosemeter with acid. The optimum treatment involves use of hydrofluoric acid at room temperature for approximately one minute, followed by thorough washing with methanol, and finally drying. This treatment is best applied after the original manufacture of the dosemeters. It may also be applied to existing dosemeters after they have been in use for some time. The treatment produces a permanent effect in reducing both the light induced signal and the non-light induced signal. The process may be applied to all types of dosemeter manufactured from PTFE or other plastics or resins which are able to resist brief exposure to acid. The treatment works particularly well with dosemeters based on PTFE and lithium fluoride. It is also applicable to dosemeters based on calcium sulphate, lithium borate and magnesium borate. Acids which may be used include hydrofluoric, hydrochloric, nitric, phosphoric and sulphuric. (author)

  13. Fundamental study on the characteristics of a radiophotoluminescence glass dosemeter with no energy compensation filter for measuring patient entrance doses in cardiac interventional procedures

    International Nuclear Information System (INIS)

    Kato, Mamoru; Chida, Koichi; Moritake, Takashi; Koguchi, Yasuhiro; Sato, Tadaya; Kadowaki, Ken; Oosaka, Hajime; Tosa, Tetsuo

    2014-01-01

    Cardiac interventional procedures have been increasing year by year. However, radiation skin injuries have been still reported. There is a necessity to measure the patient entrance skin dose (ESD), but an accurate dose measurement method has not been established. To measure the ESD, a lot of radiophotoluminescence dosemeters (RPLDs) provide an accurate measurement of the direct actual ESD at the points they are arrayed. The purpose of this study was to examine the characteristics of RPLD to measure the ESD. As a result, X-ray permeable RPLD (with no tin filter) did not interfere with the percutaneous coronary intervention procedure. The RPLD also had good fundamental performance characteristics. Although the RPLD had a little energy dependence, it showed excellent dose and dose-rate linearity, and good angular dependence. In conclusion, by calibrating the energy dependence, RPLDs are useful dosemeter to measure the ESD in cardiac intervention. (authors)

  14. Alarm personal dosemeter

    International Nuclear Information System (INIS)

    Nunomiya, Tomoya; Yamauchi, Hideshi; Shibata, Tetsuo

    2007-01-01

    Fuji Electric advanced the development of the conventional alarm personal dosemeter (APD) by adopting JIS Z 4312 (2002), which reflects IEC61526 (1998), and by improving the radiation performance characteristics, electromagnetic performance characteristics and mechanical performance characteristics of the APD (acquiring a CE marking). This new dosemeter will target overseas market in the future. The APD is a suitable dosemeter for detecting and monitoring radiation exposure to personnel working in the controlled areas of nuclear facilities, such as nuclear power stations. The APD product line includes 'gamma ray', 'gamma ray + beta ray' and 'gamma ray + neutron' models. (author)

  15. Fundamental study on the characteristics of a radiophotoluminescence glass dosemeter with no energy compensation filter for measuring patient entrance doses in cardiac interventional procedures.

    Science.gov (United States)

    Kato, Mamoru; Chida, Koichi; Moritake, Takashi; Koguchi, Yasuhiro; Sato, Tadaya; Oosaka, Hajime; Tosa, Tetsuo; Kadowaki, Ken

    2014-12-01

    Cardiac interventional procedures have been increasing year by year. However, radiation skin injuries have been still reported. There is a necessity to measure the patient entrance skin dose (ESD), but an accurate dose measurement method has not been established. To measure the ESD, a lot of radiophotoluminescence dosemeters (RPLDs) provide an accurate measurement of the direct actual ESD at the points they are arrayed. The purpose of this study was to examine the characteristics of RPLD to measure the ESD. As a result, X-ray permeable RPLD (with no tin filter) did not interfere with the percutaneous coronary intervention procedure. The RPLD also had good fundamental performance characteristics. Although the RPLD had a little energy dependence, it showed excellent dose and dose-rate linearity, and good angular dependence. In conclusion, by calibrating the energy dependence, RPLDs are useful dosemeter to measure the ESD in cardiac intervention. © The Author 2013. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Comparison test of electronic dosemeters

    International Nuclear Information System (INIS)

    Butterweck, G.; Zimmerli, H.P.; Wernli, C.

    2001-01-01

    To assist with a planned purchase of electronic dosemeters by the Swiss Federal Office for Civil Protection, the calibration laboratory of the Paul Scherrer Institute performed tests on 11 types of electronic dosemeters manufactured by 10 European and American companies. The technical specifications for the World Trade Organisation (WTO) tendering procedure were largely in accord with the specifications of the international standard IEC 61526. First tests were performed with samples from each type of dosemeter. The reproducibility of a dose of 0.1 mSv generated with 137 Cs radiation at a dose rate of 2.1 mSv.h -1 was found adequate for all tested dosemeter types. The response for environmental levels of radiation showed a large variation, indicating insufficient background correction of some dosemeters. A very high dose rate of 10 Sv.h -1 provoked faulty dose readings for more than half of the tested dosemeters. Dosemeter response for low-energy photon radiation was satisfactory for two of the tested dosemeter types. Four dosemeter types were selected for extended technical tests. Three samples of each of these dosemeter types were purchased. For drop and temperature tests the specifications of the WTO tendering procedure outranged the specification of the IEC standard. Whereas even at a temperature of -25 deg. C the tested dosemeters functioned normally, drops from a height of 2 m onto a wooden surface rendered the samples of two dosemeter types inoperative. (author)

  17. Personal neutron diode dosemeter

    International Nuclear Information System (INIS)

    Barthe, J.; Lahaye, T.; Moiseev, T.; Portal, G.

    1993-01-01

    The control and management of neutron doses, received by workers in nuclear power or research facilities, requires a knowledge of cumulated dose equivalent or dose equivalent rate in real time. Individual dosemeters so far developed for this purpose are scarce and not very satisfactory. Passive dosemeters such as TLD systems based on the albedo effect, nuclear emulsions or solid track detectors, do not give sufficiently accurate measurements. Furthermore, the increase in the quality factor and the more restrictive new ICRP recommendations diminish the maximum admissible threshold making currently used systems obsolete. Other than bubble dosemeter systems, based on thermodynamic effects of a superheated gel, no simple electronic device is available at the present time. The development of diode based dosimetric gamma badges, having a size similar to that of credit cards, has stimulated us to design and develop a personal neutron dosemeter based on a double diode system. The results obtained are very encouraging and practical models should become available in the near future. (author)

  18. Calibration of farmer dosemeters

    International Nuclear Information System (INIS)

    Ahmad, S.S.; Anwar, K.; Arshed, W.; Mubarak, M.A.; Orfi, S.D.

    1984-08-01

    The Farmer Dosemeters of Atomic Energy Medical Centre (AEMC) Jamshoro were calibrated in the Secondary Standard Dosimetry Laboratory (SSDL) at PINSTECH, using the NPL Secondary Standard Therapy level X-ray exposure meter. The results are presented in this report. (authors)

  19. Principle and use of dosemeters

    International Nuclear Information System (INIS)

    Genet, S.; Ribaud, I.

    1997-01-01

    The institute of nuclear physics of Orsay is accepted by the Ministry of Labour to insure the surveillance of workers individual external exposure against the danger of ionizing radiations and to execute monitoring of radiation protection. The dosemeters studied in this report are the photographic film dosemeters ( for x rays, gamma rays and beta - rays), the trace detectors (fast neutrons) and the radio thermo luminescent dosemeters. For each type, the principle and how to use it are given. (N.C.)

  20. A personal radon dosemeter

    International Nuclear Information System (INIS)

    Oberstedt, S.; Vanmarcke, H.

    1994-03-01

    In the last decade the radon issue has become one of the major problems of radiation protection. Animal studies as well as epidemiological studies showed an increased lung cancer risk. A new personal radon-dosemeter on the basis of a CR-39 (poly-allyl diglycol carbonate) track-etch detector has been developed. The read-out of the detectors is based on the image- processing technique. The actual efficiency of the new dosemeter, obtained with a semi-automatic personal-computer based image-analysis system, is 1.43 +/- 0.15 tracks/cm 2 /(kBq/m 3 h), which is about three times that of the widely used Karlsruhe-type detector based on polycarbonate detectors

  1. Electret dosemeter for beta radiation

    International Nuclear Information System (INIS)

    Campos, L.L.; Caldas, L.V.E.; Mascarenhas, S.

    The response characteristics of an electret dosemeter for beta radiation are studied. Experiments were performed using different geometries and walls, and it was verified for which geometry the dosemeter sensitivity is greater. Sources of 90 Sr - 90 Y, 204 Tl and 85 Kr were used in the experiments. (I.C.R.) [pt

  2. Performance tests on the NRPB thermoluminescent dosemeter

    CERN Document Server

    Shaw, K B

    1977-01-01

    Performance tests on the thermoluminescent dosemeter, designed at NRPB for use in the automated personal dosimetry system, are described. An ultra-thin lithium borate dosemeter has been developed for skin absorbed dose measurement. The X-ray, gamma-ray and beta-ray energy response of the dosemeter has been investigated and the angular response for the dosemeter has been examined. The annealing, read-out and stabilisation procedures for the dosemeter are described.

  3. The NRPB nuclear emission dosemeter

    International Nuclear Information System (INIS)

    Bartlett, D.T.; Bird, T.V.; Miles, J.C.H.

    1980-03-01

    The NRPB nuclear emulsion dosemeter is designed such that the thermal neutron response is similar to the fast neutron response. This report gives details of the dependence of response on incident neutron energy and on neutron angle of incidence. (author)

  4. New ISO standard - personnel photographic film dosemeters

    International Nuclear Information System (INIS)

    Brabec, D.

    1980-01-01

    The ISO Standard 1757 ''Personnel Photographic Film Dosemeters'', issued in June 1980, is briefly described. UVVVR's own dosemeter developed for use in the national film dosimetry service in Czechoslovakia is evaluated in relation to this ISO Standard. (author)

  5. Response of electret dosemeter to slow neutrons

    International Nuclear Information System (INIS)

    Ghilardi, A.J.P.; Pela, C.A.; Zimmerman, R.L.

    1987-01-01

    The response of electret dosemeter to slow neutrons exposure is cited, mentioning the preparation and the irradiation of dosemeter with Am-Be source. Some theory considerations about the response of electret dosemeter to slow and fast neutrons are also presented. (C.G.C.) [pt

  6. Specification for personal photographic dosemeters

    International Nuclear Information System (INIS)

    1981-01-01

    The 1981 British/International Standard Specification, prepared under the direction of the Nuclear Engineering Standards Committee and TC85 of the International Organization for Standardization, is described for personal photographic dosemeters. The Standard specifies classification, characteristics and test procedures to determine absorbed doses due to X or gamma radiations (energy less than 3 MeV) and absorbed doses due to beta radiation (max. energy 0.6 to 3 MeV), whether or not accompanied by X, gamma or bremsstrahlung photon radiation. The Standard is particularly applicable to dosemeters intended to be carried on the chest or wrist. (U.K.)

  7. A new electret dosemeter for radiotherapy

    International Nuclear Information System (INIS)

    Rodrigues, L.N.

    1985-01-01

    The results obtained with a new plane electret dosemeter for use in Radiotherapy are presented. The working principle of the electret dosemeter in based on the use of the electret field the ion collecting field, similarly to an ionization chamber, and as charge integrator detector. The dosemeter had, initialy, a cylindrical geometry. The results attained with it's calibration curve concerning the sensitivity, the stability and the reproducibility lead to changes in the dosemeter geometry. A plane geometry dosemeter was built in order to increase the useful exposure range. The plane dosemeter sensitivity dependence was measured versus the electret charging conditions, the chamber volume and wall material (aluminium, brass and stainless steel). The stainless steel dosemeter showed the best results. This dosemeter has the following characteristics: sensitivity 10 -13 C/R, volume 0.20 cm 3 . Compared to the Baldwin-Farmer dosemeter, this results are fairly good. A multiple electret dosemeter was developed to monitor the uniformity of the radiation beam for a Cobalt Teletherapy unit. The intercomparasion with the Baldwin-Farmer unit presented a maximum variation of 3%. (author) [pt

  8. Technical specification of the NRPB Nuclear Emulsion Dosemeter

    International Nuclear Information System (INIS)

    Bartlett, D.T.; Bird, T.V.

    1978-08-01

    This document is a formal specification of the NRPB Nuclear Emulsion Dosemeter. The dosemeter specified in this report replaces the NRPB Fast Neutron Personal Dosemeter specified in NRPB-R50. (author)

  9. Selected references on thermoluminescent dosemeters for personnel monitoring

    International Nuclear Information System (INIS)

    Lawson, Helen

    1976-08-01

    This bibliography contains references on: specific thermoluminescent dosemeters used for personnel dosimetry; comparisons of thermoluminescent and other dosemeters for personnel monitoring and read-out apparatus for thermoluminescent dosemeters. An appendix contains selected foreign language references. (author)

  10. Response of electret dosemeter to slow neutrons

    International Nuclear Information System (INIS)

    Ghilardi, A.J.P.; Pela, C.A.; Zimmerman, R.L.

    1987-01-01

    The response of the electret dosemeter to exposition of slow neutrons is studied. Different external coatings are used on the dosemeter (polyethylene, alminium, polyethylene + boron, aluminium + boron) and exposure curves (with and without water) are compared. (M.A.C.) [pt

  11. Fast neutron sensitivity of polymer dosemeters

    International Nuclear Information System (INIS)

    Harper, M.W.; Pearson, D.W.; Moran, P.R.

    1975-01-01

    The responses of polymer thermocurrent dosemeters to fission spectrum and 14 MeV neutrons were measured. The dosemeters are in the form of disks 1 cm diam by 0.5 mm thick. Relative to Cobalt 60 gamma responses, teflon PTFE dosemeters show a 6 percent response to 14 MeV neutrons and a 5 percent response to fission neutrons on a tissue rad basis. Polymethylpentene dosemeters show a 49 percent response to 14 MeV neutrons and a 40 percent response to fission neutrons on a tissue rad basis when provided with adequate recoil proton buildup. The sensitivity of these dosemeters is limited to neutron doses greater than 10 rads by spurious background currents

  12. EDEL: ENEA dosemeter for eye lens

    International Nuclear Information System (INIS)

    Ferrari, Paolo; Mariotti, Francesca; Campani, Lorenzo

    2016-01-01

    Since the publication of International Commission on Radiological Protection statement in 2011 on tissue reaction, eye lens radiation protection played an important role in exposed personnel dosimetry. For this reason, the Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA) Individual Monitoring Service decided to study a prototype to fulfil specific requests (e.g. for survey in interventional department and intercomparisons). On the basis of such preliminary investigation, a new eye lens dosemeter was developed. The new dosemeter, named EDEL (ENEA Dosemeter for Eye Lens), was characterised in terms of H p (3), the operational quantity related to eye lens monitoring. The investigation was performed experimentally and optimised using the Monte Carlo MCNP6 code. The new prototype was thought to fulfil two main requests: the reliability of the dosimetric data and the portability of the dosemeter itself. The new dosemeter will soon be supplied to the collaborating hospitals for workplace test measurements. (authors)

  13. New generation of ''legal'' dosemeters

    International Nuclear Information System (INIS)

    Fletcher, R.

    1991-01-01

    In the early 1980s research at the National Radiological Protection Board in the UK proved the feasibility of using solid state electronics in an entirely new dosimetry technology - capable of reaching right down into the low energy photon ranges, and able to detect beta radiation. In 1988 the NRPB undertook a joint venture with Siemens Plessey Controls to develop a marketable personal dosemeter meeting full Health and Safety Executive approval as a ''legal'' instrument. The Electronic Personal Dosemeter (EPD) was thus conceived, and will reach the pre-production stage early this year. The EPD makes use of state-of-the-art silicon integrated circuit technology, with a custom amplifier and microprocessor system. The liquid crystal display continuously shows the accumulated short-term penetrating dose in terms of the Hp (10) unit, and can also show superficial dose and dose rates. Because the EPD must be continuously powered, the custom lithium battery was commissioned to ensure a minimum service interval of 12 months. The EPD is the size and weight of a small pocket pager. Although dose data can be read directly from the EPD, a comprehensive data management system is needed to effect real-life use in industry. The EPD thus communicates by infra-red link to a reader unit which interfaces an IBM-compatible PC, allowing authorized personnel to read the dose memories and perform dose alarm threshold settings. (author)

  14. Passive neutron dosemeter with activation detector

    Energy Technology Data Exchange (ETDEWEB)

    Valero L, C.; Banuelos F, A.; Guzman G, K. A.; Borja H, C. G.; Hernandez D, V. M.; Vega C, H. R., E-mail: fermineutron@yahoo.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)

    2011-10-15

    A passive neutron dosemeter with {sup 197}Au activation detector has been developed. The area dosemeter was made as a 20.5 {phi} x 20.5 cm{sup 2} polyethylene moderator, with a polyethylene pug where a {sup 197}Au foil can be located either parallel or perpendicular to moderator axis. Using Monte Carlo methods, with the MCNP5 code. With the fluence response and the fluence-to-equivalent dose conversion coefficients from ICRP-74, responses to H*(10) were also calculated, these were compared against responses of commercially available neutron area monitors and dosemeters. (Author)

  15. Colour dosemeters for high level radiation dosimetry

    DEFF Research Database (Denmark)

    Schönbacher, H.; Coninckx, F.; Miller, A.

    1990-01-01

    interpretation or a dose measurement with a simple instrument such as a portable reflecting densitometer in the range of 10(3) to 10(6) Gy. Two projects were investigated: (1) a thin plastic film with a self adhesive tape containing a radiochromic dye which induces a colour change when exposed to ionising...... of paint and film dosemeters were installed in the 450 GeV Super Proton Synchrotron (SPS) at CERN and irradiated during operation for more than two years. Within the useful range of the dosemeters, dose comparisons with other dosemeter types gave satisfactory results. Application in other fields...

  16. Study about the feasibility of using an electret dosemeter as a personal dosemeter

    International Nuclear Information System (INIS)

    Leitao, I.P.

    1983-01-01

    A feasibility study of the electret dosemeters as a personnel dosemeter was carried out. Preliminary tests were applied, in order to assess the dosemeter response to radiation, linearity, stability, reproductibility, direcional dependence and energy dependence in energy range from 33 to 1250 KeV. In general the results are in agreement with the recommendations of the Commision of the European Communities (CEC) for the use of this device as a personnel dosemeter with the exception of the energy dependence and the stability at medium term. (Author) [pt

  17. The need for comparison of diagnostic dosemeters

    International Nuclear Information System (INIS)

    Kramer, H.M.

    1989-01-01

    One precondition for successfully implementing quality control in diagnostic radiology is that the measuring instruments used are of adequate quality. Among the measuring instruments used for quality control, dosemeters play a predominant role. Therefore it is essential to know the performance characteristics of a suitable dosemeter and to have information on the uncertainties and measurement errors found during acceptance testing. An outline will be given of the requirements on the accuracy of dosemeters. Such requirements have to address the task of the dosemeter and also take into account their technical feasibility. In order to gather information on the performance characteristics of field instruments, a programme for a European intercomparison has been developed which was carried out in 1988. The programme, together with its underlying ideas and its objectives, is presented in this paper. (author)

  18. Evaluation of film dosemeters by linear programming

    International Nuclear Information System (INIS)

    Kragh, P.; Nitschke, J.

    1992-01-01

    An evaluation method for multi-component dosemeters is described which uses linear programming in order to decrease the dependence on energy and direction. The results of this method are more accurate than those obtained with the evaluation methods so far applied in film dosimetry. In addition, systematic errors can be given when evaluating individual measurements. Combined linear programming, as a special case of the presented method, is described taking a film dosemeter of particular type as an example. (orig.) [de

  19. Needle-type differential thermoluminescent dosemeter

    International Nuclear Information System (INIS)

    Kubu, M.

    1988-01-01

    The dosemeter serves to measure the depth distribution of absorbed dose in a phantom in mixed neutron and gamma radiation fields. It consists of a stratified cylindrical absorber in which alternate moderator and cadmium layers. Inside are two bores along the longitudinal axis for tubes filled with 6 LiF and 7 LiF powder thermoluminescent dosemeters. The device is easily portable and allows to carry out measurements with a high level of reproducibility. (J.B.). 4 figs

  20. Personnel monitoring of radiations with thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Miano, S.C.

    1987-01-01

    The basics of personnel dosimetry technics, used by the Radiologic Protetion and Assessorie Service (SAPRA) are presented, consisting on use of thermoluminescent and CaSO 4 :Dy monitors in aggregated pellets by Teflon. The characteristics of this dosemeters, relating to the sensitivity, energetic dependence, spike temperature, characteristic emission curve, decay and light effect are shown. The thermoluminescent dosemeter measure system and the personnel monitoring system are also described. (C.G.C.) [pt

  1. Glasses

    DEFF Research Database (Denmark)

    Dyre, Jeppe

    2004-01-01

    The temperature dependence of the viscosity of most glassforming liquids is known to depart significantly from the classical Arrhenius behaviour of simple fluids. The discovery of an unexpected correlation between the extent of this departure and the Poisson ratio of the resulting glass could lead...... to new understanding of glass ageing and viscous liquid dynamics....

  2. Self-indicating radiation alert dosemeter (SIRAD)

    International Nuclear Information System (INIS)

    Riel, G. K.; Winters, P.; Patel, G.; Patel, P.

    2006-01-01

    In an event of a nuclear or dirty bomb explosion and a radiological accident, there is a need for self-indicating instant radiation dosemeter for monitoring radiation exposure. The self-indicating instant radiation alert dosemeter (SIRAD) is a credit card size radiation dosemeter for monitoring ionising radiation from a few hundredths of a Gray to a few Gray. It is always active and is ready to use. It needs no battery. The dosemeter develops colour instantly upon exposure, and the colour intensifies with dose. It has a colour chart so that the dose on the active element may be read by matching its colour with the chart that is printed next to it on the card. However, in this work, the dose is measured by the optical density of the element. The dosemeter cannot be reset. The response changes by 3 y at room temperature. It contains no hazardous materials. The dosemeter would meet the requirements of instantly monitoring high dose in an event of a nuclear or dirty bomb explosion or a radiation accident. (authors)

  3. Self-indicating radiation alert dosemeter (SIRAD).

    Science.gov (United States)

    Riel, Gordon K; Winters, Patrick; Patel, Gordhan; Patel, Paresh

    2006-01-01

    In an event of a nuclear or dirty bomb explosion and a radiological accident, there is a need for self-indicating instant radiation dosemeter for monitoring radiation exposure. The self-indicating instant radiation alert dosemeter (SIRAD) is a credit card size radiation dosemeter for monitoring ionising radiation from a few hundredths of a Gray to a few Gray. It is always active and is ready to use. It needs no battery. The dosemeter develops colour instantly upon exposure, and the colour intensifies with dose. It has a colour chart so that the dose on the active element may be read by matching its colour with the chart that is printed next to it on the card. However, in this work, the dose is measured by the optical density of the element. The dosemeter cannot be reset. The response changes by 3 y at room temperature. It contains no hazardous materials. The dosemeter would meet the requirements of instantly monitoring high dose in an event of a nuclear or dirty bomb explosion or a radiation accident.

  4. Results of the EURATOM programme for comparison of individual dosemeters

    International Nuclear Information System (INIS)

    Julius, H.W.

    1976-01-01

    The results of the EURATOM dosemeter comparison-program for dosemeters used in the member states are given. Especially the results obtained in the Netherlands are examined and evaluated. The design and characteristics of the badge developed by the TNO-RD which are based on a thermoluminescent dosemeter are given

  5. Calibrations of pocket dosemeters using a comparison method

    International Nuclear Information System (INIS)

    Somarriba V, I.

    1996-01-01

    This monograph is dedicated mainly to the calibration of pocket dosemeters. Various types of radiation sources used in hospitals and different radiation detectors with emphasis on ionization chambers are briefly presented. Calibration methods based on the use of a reference dosemeter were developed to calibrate all pocket dosemeters existing at the Radiation Physics and Metrology Laboratory. Some of these dosemeters were used in personnel dosimetry at hospitals. Moreover, a study was realized about factors that affect the measurements with pocket dosemeters in the long term, such as discharges due to cosmic radiation. A DBASE IV program was developed to store the information included in the hospital's registry

  6. A new extremity dosemeter for beta and gamma radiation

    International Nuclear Information System (INIS)

    Heinzelmann, M.; Pagenkamper, M.

    1988-01-01

    An extremity dosemeter developed at the Juelich Nuclear Research Centre is very well suited for the precise and energy-independent measurement of the skin dose generated by beta or gamma radiation. This is also confirmed by the results of this intercomparison programme. The dosemeter contains three TLDs of LiF in Teflon mounted behind a window of 0.9 mg/cm 2 . The great advantage of this dosemeter is three TLD's enabling statements about the radiation quality. However, the dosemeter has two disadvantages The dosemeter is complicated to manufacture. A very thin plastic foil of 0.9 mg/cm 2 must be attached to a support. This work is difficult and time-consuming and cannot be automated. The window in front of the TLD is not sturdy enough and is occasionally destroyed when the dosemeter is being worn. These two disadvantages prevent this extremity dosemeter from being used more frequently. For this reason, work was begun on developing a new extremity dosemeter without these two disadvantages. The great advantage of the previous dosemeter of obtaining statements about the type of radiation with the aid of readings from three TLD's was to be retained. The improved extremity dosemeter has a more sturdy and thicker window with a similar response as the previous dosemeter with a thinner window

  7. Unbiased metal oxide semiconductor ionising radiation dosemeter

    International Nuclear Information System (INIS)

    Kumurdjian, N.; Sarrabayrouse, G.J.

    1995-01-01

    To assess the application of MOS devices as low dose rate dosemeters, the sensitivity is the major factor although little studies have been performed on that subject. It is studied here, as well as thermal stability and linearity of the response curve. Other advantages are specified such as large measurable dose range, low cost, small size, possibility of integration. (D.L.)

  8. Using operational equipment to read accident dosemeters.

    Science.gov (United States)

    Devine, R T; Vigil, M M; Martinez, W A

    2004-01-01

    Analysis of accident dosemeters usually involves the use of laboratory-based counting equipment. Gamma spectrometers are used for indium, copper and gold, and alpha-beta detectors for sulphur. This equipment is usually not easily transported due to the shielding required and the weight and delicacy of the counters. For intercomparison studies that require reading the dosemeters on site, a transportable system is required unless the site operating the study can count samples for all the participants. In the case of an actual accident these systems would have a difficulty in counting a large number of accident dosemeters. In an accident, personnel are usually subdivided according to their level of exposure. Those exposed to higher doses are treated immediately. An alternate system should be made available to handle the dosemeters worn by those personnel are likely to receive lower doses. Improvements in portable operational equipment for gamma and beta monitoring allow their use as spectrometers. Such a system was used for the SILENE intercomparison conducted at IRSN Valduc on 12 June and 19, 2002, and the preliminary results compared well with the other participants.

  9. Influence of different types of phantoms on the calibration of dosemeters for eye lens dosimetry

    International Nuclear Information System (INIS)

    Yoshitomi, H.; Kowatari, M.

    2016-01-01

    Both a cylinder and a slab phantom have been recommended to be used as calibration phantoms for eye lens dosimetry in the International Atomic Energy Agency TECDOC. This study describes investigations on the influence of the type of phantom on the calibration of dosemeters. In order to fulfil the purpose, backscatter radiation from practically used water-filled phantoms was evaluated by calculations and experiments. For photons, the calculations showed that the cylinder phantom had 10 % lower backscattered effect at maximum than a slab phantom, and simulated well the backscattered effect of the human head or neck to within ±10 %. The irradiation results of non-filtered optically stimulated luminescence and radio-photoluminescence glass dosemeters indicated that the differences of the calibration factors between the two types of phantoms were up to 20 and 10 %, respectively, reflecting the response to backscattered photons. For electrons, no difference was found between the two types of phantoms. (authors)

  10. The NRPB automated thermoluminescent dosemeter and dose record keeping system

    International Nuclear Information System (INIS)

    Dennis, J.A.; Marshall, T.O.; Shaw, K.B.

    1975-03-01

    This report describes the thermoluminescent personal radiation dosemeter and its associated automated processing equipment, which are being developed by the National Radiological Protection Board, together with the operation of a computerised dosemeter issue and record keeping system. The main justifications for introducing these systems are improvements in the organizational efficiency of the maintenance of individual dose records, a more flexible and accurate dosimetry system, and economics in operational costs. The dosemeter is based on a numbered aluminium plate containing two lithium fluoride in polytetrafluorethylene disks for the measurement of surface and body dose. This dosemeter is wrapped in thin plastic and labelled with the wearer's name and address. On return, the dosemeter is checked automatically for radioactive contamination; it is unwrapped and evaluated; the dose readings are included in the wearer's stored dose record; the dosemeter is annealed and is then available for re-issue to another wearer. Dose reports and warnings are automatically issued to the wearer or his employer. (author)

  11. Factors affecting polyamide prototypes design of Albedo dosemeters

    International Nuclear Information System (INIS)

    Martins, M.M.; Mauricio, C.L.P.; Fonseca, E.S.

    1996-01-01

    This work studies the most important factors which affect the response of albedo neutron dosemeters containing LiF TLDs with the aim to improve their sensitivity. It includes tests of thickness and shape of the polyamide moderator body prototypes, albedo window diameter and TLD position inside the moderator. Analyzing the results, an albedo neutron dosemeter prototype, B 4 C covered, was developed. The prototype has a response three times higher than the albedo dosemeter now in use in Brazil. (author)

  12. Thermoluminescence dosemeter for personal dose equivalent assessment

    International Nuclear Information System (INIS)

    Silva, T.A. da; Rosa, L.A.R. da; Campos, L.L.

    1995-01-01

    The possibility was investigated of utilising a Brazilian thermoluminescence individual dosemeter, usually calibrated in terms of photon dose equivalent, for the assessment of the personal dose equivalent, H p (d), at depths of 0.07 and 10 mm. The dosemeter uses four CaSO 4 :Dy thermoluminescent detectors, between different filters, as the sensitive materials. It was calibrated in gamma and X radiation fields in the energy range from 17 to 1250 keV. Linear combinations of the responses of three detectors, in this energy range, allow the evaluation of H p (0.07) and H p (10), for radiation incidence angles varying from 0 to 60 degrees, with an accuracy better than 35%. The method is not applicable to mixed photon-beta fields. (author)

  13. Energy dependence of pMOS dosemeters

    International Nuclear Information System (INIS)

    Savic, Z.; Stankovic, S.; Kovacevic, M.; Petrovic, M.

    1996-01-01

    The results are presented of experimental work and numerical simulations of the energy response for pMOS dosimetric transistors in their custom packages. Specially produced radiation soft pMOS transistors were used in this experimental work. The irradiation of pMOS dosemeters was done using 60 Co and 137 Cs sources, a dosimetric X ray unit, and a radiotherapeutic linear accelerator in the range of photon energies from 21 keV to 8 MeV. The results show that package geometry and materials can significantly affect and smooth the energy dependence of pMOS transistors and that in custom transistor packages they are not tissue-equivalent dosemeters. Their response in the photon energy range of 45 to 250 keV is significantly larger than it should be (maximum dose enhancement factor can be as high as 8) and some energy compensation techniques must be used in order to fulfill the requirements of corresponding standards. (Author)

  14. Two miniature electronic dosemeters Yperwatch - Gamcard

    International Nuclear Information System (INIS)

    Clavel, B.; Jaillon, J.

    1993-01-01

    Yperwatch and Gamcard were miniature electronic gamma personal dose and dose rate monitors. The Yperwatch is mounted in a wristwatch and the Gamcard in a case of the size of a standard credit card. The technology provides users with all the performance of a standard professional electronic dosemeter (integrated dose, dose rate, audible alarms, time in use). Yperwatch and Gamcard are based on well-proven electronic dosimetry technology, but with a greater ease of use. (author)

  15. Personal radiation monitoring with thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Miano, S.C.

    1987-01-01

    The technique of personal dosimetry used by SAPRA (Servico de Assessoria e Protecao Radiologica S/C Ltda., Brazil) is presented. Thermoluminescent monitors and CaSO 4 : Dy are used in pastilles united by teflon. Characteristics of the dosemeters are briefly reported. The system of thermoluminescent measurement, designed and constructed by SAPRA, and the system of personal monitoring are described. (M.A.C.) [pt

  16. A personal dosemeter of radon daughter products

    International Nuclear Information System (INIS)

    Burian, I.; Richter, M.; Ochec, J.; Dohnal, J.

    1990-01-01

    The OD 88 personal dosemeter for radon daughter products uses an alpha particle track detector and is of active type, with forced air aspiration through the detecting system. The pumping device consists of a miniature membrane pump and an electronic speed controller. The air flow rate is little affected by normal changes in supply voltage and/or pneumatic resistance of the pump circuit. The dosemeter is embedded in a miner's lamp and is fed from its accumulator battery. The pumping device is activated as the lamp is taken out of the charger and deactivated as it is slid into the charger again. The dosemeter head accommodates an AFPC filter on which the radon daughter products deposit. The energy of the alpha particles is reduced by an air layer and a Makrofol decelerating foil. The particles hitting the detector give rise to defects with an intensity proportional to the total linear stopping power at the moment of incidence; ideal tracks 10 μm in size require incident energy of 1.1 to 1.3 MeV. The detector is replaced in a month and worked up in an etching vessel, making use of the higher solubility of the detecting layer of the foil in NaOH at the spot of the alpha particle incidence. (P.A.). 4 figs., 17 refs

  17. EURADOS intercomparison 2012 for neutron dosemeters

    International Nuclear Information System (INIS)

    Fantuzzi, E.; Chevallier, M.A.; Cruz-Suarez, R.; Luszik-Bhadra, M.; Mayer, S.; Thomas, D.J.; Tanner, R.; Vanhavere, F.

    2014-11-01

    EURADOS, within the work performed by Working Group 2 - Harmonization of Individual Monitoring in Europe, has started a self-sustained programme of regular intercomparisons and has successfully executed three intercomparisons for whole body photon dosemeters (IC2008, IC2010, IC2012) and one intercomparison for extremity dosemeters for photon and beta fields (IC2009). In 2012, the EURADOS intercomparison IC2012n was launched for personal neutron dosemeters routinely used to measure personal dose equivalent, Hp(10), in individual monitoring. No systems under development were allowed to participate. IC2012n was carried out by a EURADOS nominated Organization Group (OG) consisting of: Marie- Anne Chevallier (IRSN, F), Rodolfo Cruz-Suarez (IAEA, UN-Vienna), Marlies Luszik-Bhadra (PTB, D), Sabine Mayer (PSI, CH), David J. Thomas (NPL, UK), Rick Tanner (PHE, UK), Filip Vanhavere (SCK-CEN, B) led by a Coordinator, Elena Fantuzzi (ENEA, I). 31 participants registered for the comparison, with 34 dosimetry systems. In total 816 dosemeters were irradiated in selected neutron fields on an ISO slab phantom. The irradiations were performed at 2 European accredited laboratories which are both National Primary Metrology Laboratories for ionizing radiation: NPL (National Physical Laboratory, UK) and PTB (Physikalisch-Technische Bundesanstalt, D). All irradiations were carried out according to the irradiation plan developed by the OG. The overall results show that most, although not all, dosimetric systems perform acceptably well (within a factor of 2) for irradiations with a bare radionuclide source ( 252 Cf at 0 ), whilst more than half of the systems underestimate the reference value for irradiations from non-normal angles of incidence irradiations ( 252 Cf at 45 ) or for simulated workplace fields ( 252 Cf(D 2 O) or 252 Cf source behind a shadow cone). The performance for 250 keV mono-energetic neutron irradiations varies mainly reflecting the detection principle on which the

  18. EURADOS intercomparison 2012 for neutron dosemeters

    Energy Technology Data Exchange (ETDEWEB)

    Fantuzzi, E. [ENEA-Radiation Protection Institute, Bologna (Italy); Chevallier, M.A. [Institut de Radioprotection et de Surete Nucleaire (IRSN), Fontenay-aux-Roses (France); Cruz-Suarez, R. [International Atomic Energy Agency, Vienna (Austria); Luszik-Bhadra, M. [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany); Mayer, S. [Paul Scherrer Institute (PSI), Villigen (Switzerland); Thomas, D.J. [National Physical Laboratory (NPL), Teddington (United Kingdom); Tanner, R. [Public Health England, Oxon (United Kingdom); Vanhavere, F. [SCK-CEN, Belgian Nuclear Research Centre, Mol (Belgium)

    2014-11-15

    EURADOS, within the work performed by Working Group 2 - Harmonization of Individual Monitoring in Europe, has started a self-sustained programme of regular intercomparisons and has successfully executed three intercomparisons for whole body photon dosemeters (IC2008, IC2010, IC2012) and one intercomparison for extremity dosemeters for photon and beta fields (IC2009). In 2012, the EURADOS intercomparison IC2012n was launched for personal neutron dosemeters routinely used to measure personal dose equivalent, Hp(10), in individual monitoring. No systems under development were allowed to participate. IC2012n was carried out by a EURADOS nominated Organization Group (OG) consisting of: Marie- Anne Chevallier (IRSN, F), Rodolfo Cruz-Suarez (IAEA, UN-Vienna), Marlies Luszik-Bhadra (PTB, D), Sabine Mayer (PSI, CH), David J. Thomas (NPL, UK), Rick Tanner (PHE, UK), Filip Vanhavere (SCK-CEN, B) led by a Coordinator, Elena Fantuzzi (ENEA, I). 31 participants registered for the comparison, with 34 dosimetry systems. In total 816 dosemeters were irradiated in selected neutron fields on an ISO slab phantom. The irradiations were performed at 2 European accredited laboratories which are both National Primary Metrology Laboratories for ionizing radiation: NPL (National Physical Laboratory, UK) and PTB (Physikalisch-Technische Bundesanstalt, D). All irradiations were carried out according to the irradiation plan developed by the OG. The overall results show that most, although not all, dosimetric systems perform acceptably well (within a factor of 2) for irradiations with a bare radionuclide source ({sup 252}Cf at 0 ), whilst more than half of the systems underestimate the reference value for irradiations from non-normal angles of incidence irradiations ({sup 252}Cf at 45 ) or for simulated workplace fields ({sup 252}Cf(D{sub 2}O) or {sup 252}Cf source behind a shadow cone). The performance for 250 keV mono-energetic neutron irradiations varies mainly reflecting the detection

  19. Feasibility of a neutron detector-dosemeter based on single-event upsets in dynamic random-access memories

    International Nuclear Information System (INIS)

    Phillips, G.W.; August, R.A.; Campbell, A.B.; Nelson, M.E.; Guardala, N.A.; Price, J.L.; Moscovitch, M.

    2002-01-01

    The feasibility was investigated of a solid-state neutron detector/dosemeter based on single-event upset (SEU) effects in dynamic random-access memories (DRAMs), commonly used in computer memories. Such a device, which uses a neutron converter material to produce a charged particle capable of causing an upset, would be light-weight, low-power, and could be read simply by polling the memory for bit flips. It would have significant advantages over standard solid-state neutron dosemeters which require off-line processing for track etching and analysis. Previous efforts at developing an SEU neutron detector/dosemeter have suffered from poor response, which can be greatly enhanced by selecting a modern high-density DRAM chip for SEU sensitivity and by using a thin 10 B film as a converter. Past attempts to use 10 B were not successful because the average alpha particle energy was insufficient to penetrate to the sensitive region of the memory. This can be overcome by removing the surface passivation layer before depositing the 10 B film or by implanting 10B directly into the chip. Previous experimental data show a 10 3 increase in neutron sensitivity by chips containing borosilicate glass, which could be used in an SEU detector. The results are presented of simulations showing that the absolute efficiency of an SEU neutron dosemeter can be increased by at least a factor of 1000 over earlier designs. (author)

  20. Dosemeter calibration in X-ray and in cobalt-60

    International Nuclear Information System (INIS)

    Silva, T.A. da

    1988-01-01

    Some tests about quality security for clinical dosemeter calibration in secondary standard dosimetry laboratory are described. The tests in gama calibration system, in X-ray calibration, in secondary standard dosimeter, in the dosemeter that will be calibrated, during the calibration and after the calibration are shown. (C.G.C.) [pt

  1. A new, passive dosemeter for gamma, beta and neutron radiations

    Energy Technology Data Exchange (ETDEWEB)

    Jones, L A; Stokes, R P, E-mail: rpstokes@dstl.gov.uk [Defence Science and Technology Laboratory, Environmental Sciences Department, Alverstoke, Gosport, Hants, PO12 2DL (United Kingdom)

    2011-03-01

    The Defence Science and Technology Laboratory (Dstl) provides personal radiation dosimetry to the UK Ministry of Defence. Dstl has recently developed a dosemeter that is based on a combination of thermoluminescent and etched-track detectors. The Dstl Combined Dosemeter is capable of assessing doses due to photons, beta particles and neutrons. This paper presents the laboratory type testing results for the Combined Dosemeter, and also describes the procedure for calibrating the dosemeter for use in workplace neutron fields. The Combined Dosemeter meets the type test requirements that are relevant to its intended applications, and gives neutron doses that are within 50% of the true dose in the workplaces in which it is used, even when the wearer has the potential to be exposed to a variety of neutron spectra (e.g. on board nuclear-powered submarines).

  2. A new, passive dosemeter for gamma, beta and neutron radiations

    International Nuclear Information System (INIS)

    Jones, L A; Stokes, R P

    2011-01-01

    The Defence Science and Technology Laboratory (Dstl) provides personal radiation dosimetry to the UK Ministry of Defence. Dstl has recently developed a dosemeter that is based on a combination of thermoluminescent and etched-track detectors. The Dstl Combined Dosemeter is capable of assessing doses due to photons, beta particles and neutrons. This paper presents the laboratory type testing results for the Combined Dosemeter, and also describes the procedure for calibrating the dosemeter for use in workplace neutron fields. The Combined Dosemeter meets the type test requirements that are relevant to its intended applications, and gives neutron doses that are within 50% of the true dose in the workplaces in which it is used, even when the wearer has the potential to be exposed to a variety of neutron spectra (e.g. on board nuclear-powered submarines).

  3. Calibration procedures for mammography dosemeters in Poland

    International Nuclear Information System (INIS)

    Gwiazdowska, B.; Ulkowski, P.; Tolwinski, J.; Bulski, W.

    2002-01-01

    Breast cancer is the most frequent tumour in women and the effectiveness of the treatment depends dramatically on the early detection of the disease. That is the reason why in Poland the mammography control examinations are strongly supported by the Centre of Oncology. In Poland there are over 400 mammography units which account for about 300,000 examinations per year. An investigation performed by the Medical Physics Department of the Centre of Oncology in Warsaw at about 100 mammography facilities proved that in most cases the doses absorbed by the patients could be reduced without decrease of image quality. This is one of the reasons why the Polish Secondary Standard Dosimetry Laboratory (SSDL) dealing mainly with calibration of radiotherapy dosemeters is extending its activities and therefore new facilities and equipment adapted for calibration of mammographic dosemeters have been installed. The mammography dosimetry calibration equipment is permanently installed in the same laboratory room where the radiotherapy dosemeters are calibrated. A base of a mammography unit no longer in clinical use, together with its movable system has been adapted to handle ionization chamber holders. An X-ray tube with a 50 kV high frequency generator was also installed. The tube, a Varian type OEG-50-2, (designed for laboratory applications) with molybdenum anode of an anode angle 23,7 deg. and with a large focus, effective size approximately 5 mm 2 , has an inherent filtration of 0,25 mm beryllium. It is installed in a housing with 2mm lead shielding; a cone shaped beam is formed by a system of three collimators

  4. Comparing different error-conditions in film dosemeter evaluation

    International Nuclear Information System (INIS)

    Roed, H.; Figel, M.

    2007-01-01

    In the evaluation of a film used as a personal dosemeter it may be necessary to mark the dosemeters when possible error-conditions are recognised, such as errors that have an influence on the ability to make a correct evaluation of the dose value. In this project a comparison has been carried out to examine how two individual monitoring services, IMS [National Inst. of Radiation Hygiene (Denmark) (NIRH) and National Research Centre for Environment and Health (Germany) (GSF)], from two different EU countries mark their dosemeters. The IMS are different in size, type of customers and issuing period, but both use films as their primary dosemeters. The error-conditions examined are dosemeters exposed to moisture or light, contaminated dosemeters, films exposed outside the badge, missing filters in the badge, films inserted incorrectly in the badge and dosemeters not returned or returned too late to the IMS. The data are collected for the year 2003 where NIRH evaluated ∼50,000 and GSF ∼1.4 million film dosemeters. The percentage of film dosemeters is calculated for each error-condition as well as the distribution among eight different employee categories, i.e. medicine, nuclear medicine, nuclear industry, industry, radiography, laboratories, veterinary and others. It turned out, that incorrect insertion of the film in the badge was the most common error-condition observed at both IMS and that veterinarians, as the employee category, generally have the highest number of errors. NIRH has a significantly higher relative number of dosemeters in most error-conditions than GSF, which perhaps reflects that a comparison is difficult due to different systemic and methodical differences between the IMS and countries, e.g. regulations and monitoring programs etc. Also the non-existence of a common categorisation method for employee categories contributes to make a comparison like this difficult. (authors)

  5. Utilization of thermoluminescent dosemeters for determination of exposure or absorbed dose in a radiation gamma or X radiation field with unknown spectral distribution

    International Nuclear Information System (INIS)

    Rosa, L.A.R. da.

    1981-06-01

    Having in view the choice of the best pair of dosemeters to be used in the 'Tandem' method, the main response characteristics of LiF:Mg, Ti, Li 2 B 4 O 7 :Mn, CaSO 4 Dy, CaF 2 :Mn and CaF 2 :Dy thermoluminescent dosemeters and also some critical parameters in their calibration and evaluation processes were studied. Three different physical forms of TLD's were investigated: hot pressed chips, disc teflon dosemeters and glass mini TLD's. Their calibration factors were obtained for the energy of Cobalt-60 gamma rays. Their energy dependences normalized to 60 Co radiation were determined using spectral width as parameter. 'Tandens' formed by all TLD's evaluated were compaired. (E.G.) [pt

  6. Characteristics and performances of electronic personal dosemeters

    International Nuclear Information System (INIS)

    Aubert, B.

    2002-01-01

    The regulations have made obligation for 2 years to measure and analyse the amounts of radiations actually received during an operation. The whole of these measurements taken uninterrupted for an immediate reading is indicated like the operational dosimetry, which is carried out with the means of personal electronic dosemeters. This study analyses the legislation relating to this type of dosimetry as well as the requirements in medical environment, and presents an assessment of the characteristics and performances of the devices available on the French market at the beginning of 2002 starting from the information provided by the various manufacturers. (author)

  7. Individual dosemeter with ionization chamber for intervention

    International Nuclear Information System (INIS)

    Prigent, M.

    1982-01-01

    The altogether intervention ratemeter-dosemeter is a device for work condition control and for dosimetry of intervention gang in hostile medium. A portable irradiation marker with ionization chamber either carried by staff, either put at the work post, delivers an information function of the surrounding irradiation field in which moves the intervention staff. The information is processed so as the absorbed dose rate and the absorbed dose are given simultaneously. The connection between the marker and the process device is made by a cable (up to 100m) or by radio link [fr

  8. Improvement of personal dosimetry - Digital pocket dosemeter

    International Nuclear Information System (INIS)

    Radalj, Z.; Cerovac, Z.; Cerovac, H.; Brumen, V.; Prlic, I.

    1996-01-01

    Physical dosimetric surveillance of professional groups working with various radiation sources is a regular procedure in Croatia, established almost 40 years ago. Data available point out that the majority of professionals under surveillance are those employed in medical facilities, most of them working with X-ray sources. Depending on the nature of professional activities, personnel occupationally exposed to radiation sources are obliged to wear either film badge, TLD or film+TLD badge. Unfortunately, due to the line of data processing, all standard dosemeters have the same disadvantage i.e. up to 40 days delay in dose reporting, regarding the time of actual exposure. The significance of such a delay raises in cases when radiation dose was received within the short time or when technical failure on the operating unit(s) is suspected. Bearing this in mind, the additional dosimetric monitoring becomes an imperative. Therefore, we decided to introduce a palette of digital pocket dosemeters, meant to be used in different workplaces in the radiation zone, each of them being adjusted to the specificities of a particular workplace

  9. A neutron dosemeter for nuclear criticality accidents.

    Science.gov (United States)

    d'Errico, F; Curzio, G; Ciolini, R; Del Gratta, A; Nath, R

    2004-01-01

    A neutron dosemeter which offers instant read-out has been developed for nuclear criticality accidents. The system is based on gels containing emulsions of superheated dichlorodifluoromethane droplets, which vaporise into bubbles upon neutron irradiation. The expansion of these bubbles displaces an equivalent volume of gel into a graduated pipette, providing an immediate measure of the dose. Instant read-out is achieved using an array of transmissive optical sensors which consist of coupled LED emitters and phototransistor receivers. When the gel displaced in the pipette crosses the sensing region of the photomicrosensors, it generates a signal collected on a computer through a dedicated acquisition board. The performance of the device was tested during the 2002 International Accident Dosimetry Intercomparison in Valduc, France. The dosemeter was able to follow the initial dose gradient of a simulated accident, providing accurate values of neutron kerma; however, the emulsion was rapidly depleted of all its drops. A model of the depletion effects was developed and it indicates that an adequate dynamic range of the dose response can be achieved by using emulsions of smaller droplets.

  10. Energy dependence of pMOS dosemeters

    Energy Technology Data Exchange (ETDEWEB)

    Savic, Z. [Military Technical Institute, Belgrade (Yugoslavia); Stankovic, S.; Kovacevic, M.; Petrovic, M. [Institute of Nuclear Sciences, Belgrade (Yugoslavia). Radiation Protection Dept.

    1996-10-01

    The results are presented of experimental work and numerical simulations of the energy response for pMOS dosimetric transistors in their custom packages. Specially produced radiation soft pMOS transistors were used in this experimental work. The irradiation of pMOS dosemeters was done using {sup 60}Co and {sup 137}Cs sources, a dosimetric X ray unit, and a radiotherapeutic linear accelerator in the range of photon energies from 21 keV to 8 MeV. The results show that package geometry and materials can significantly affect and smooth the energy dependence of pMOS transistors and that in custom transistor packages they are not tissue-equivalent dosemeters. Their response in the photon energy range of 45 to 250 keV is significantly larger than it should be (maximum dose enhancement factor can be as high as 8) and some energy compensation techniques must be used in order to fulfill the requirements of corresponding standards. (Author).

  11. A neutron dosemeter for nuclear criticality accidents

    International Nuclear Information System (INIS)

    D'Errico, F.; Curzio, G.; Ciolini, R.; Del Gratta, A.; Nath, R.

    2004-01-01

    A neutron dosemeter which offers instant read-out has been developed for nuclear criticality accidents. The system is based on gels containing emulsions of superheated dichlorodifluoromethane droplets, which vaporise into bubbles upon neutron irradiation. The expansion of these bubbles displaces an equivalent volume of gel into a graduated pipette, providing an immediate measure of the dose. Instant read-out is achieved using an array of transmissive optical sensors which consist of coupled LED emitters and phototransistor receivers. When the gel displaced in the pipette crosses the sensing region of the photo microsensors, it generates a signal collected on a computer through a dedicated acquisition board. The performance of the device was tested during the 2002 International Accident Dosimetry Intercomparison in Valduc (France)). The dosemeter was able to follow the initial dose gradient of a simulated accident, providing accurate values of neutron kerma; however, the emulsion was rapidly depleted of all its drops. A model of the depletion effects was developed and it indicates that an adequate dynamic range of the dose response can be achieved by using emulsions of smaller droplets. (authors)

  12. The new IRSN passive dosemeter using the RPL technique

    International Nuclear Information System (INIS)

    Fraboulet, P.; Cale, E.; Itie, C.; Bottollier-Depois, Jean-Francois

    2008-01-01

    Full text: The Institute for Radiological Protection and Nuclear Safety (IRSN) is the French public organisation in charge of research and expertise into nuclear safety and radiation protection. IRSN provides also services in these areas like dosimetric survey for 150,000 workers liable to be exposed to ionising radiation. At present whole-body dosemeters provided by the IRSN laboratory for photons and beta-particles are based on photographic films. In order to anticipate likely supplying decrease and to improve the service, IRSN has decided to replace photographic films by dosemeters based on the radio-photoluminescence (RPL) technology, supplied by the Japanese Company Chiyoda Technol. RPL was chosen after a thorough comparison with other available passive techniques (thermoluminescent dosemeters: TLD, and optically stimulated luminescence: OSL). Constraints due to large-scale production of dosemeters (packaging, shipping, etc.) were taken into account as well. Irradiation tests for five different dosemeters, based on the 3 available techniques (TLD, OSL, RPL) were performed. The main results of these tests are presented (energy, dose and angular response, detection threshold, etc.) together with main technical characteristics of the new RPL dosemeter (range in energy and dose, homogeneity, reproducibility, re-reading, information about radiation type from reading, etc.). This dosemeter is expected to give significative improvements in the IRSN laboratory's provision of service thanks to better dosimetric performances and because it offers the possibility to get information to analyse over-exposure circumstances. (author)

  13. Dosimetric characteristics of a TLD dosemeter with extremities

    International Nuclear Information System (INIS)

    Molina P, D.; Diaz B, E.; Lien V, R.

    1999-01-01

    It was designed a TLD dosemeter for the monitoring of the extremities. This one consists in a metallic ring with a circular orifice where is arranged a T L detector of LiF: Mg,Ti (Model JR1152C) 5 x 5 x 0.8 mm 3 covered by a polyethylene fine layer. In this work were studied the dosimetric properties of the dosemeter for its application in the dosimetry of extremities for photonic radiation. the results obtained allow conclude that the designed dosemeter can be used for the extremities monitoring. (Author)

  14. Characteristics of dosemeter types for skin dose measurements in practice

    International Nuclear Information System (INIS)

    Van, D. J.; Bosmans, H.; Marchal, G.; Wambersie, A.

    2005-01-01

    A growing number of papers report deterministic effects in the skin of patients who have undergone interventional radiological procedures. Dose measurements, and especially skin dose measurements, are therefore increasingly important. Methods and acceptable dosemeters are, however, not clearly defined. This paper is the result of a literature overview with regard to assessing the entrance skin dose during radiological examinations by putting a dosemeter on the patient's skin. The relevant intrinsic characteristics, as well as some examples of clinical use of the different detector types, are presented. In this respect, thermoluminescence, scintillation, semiconductor and film dosemeters are discussed and compared with respect to their practical use. (authors)

  15. Environmental radiation measurements using lithium fluoride thermoluminescence dosemeters

    Energy Technology Data Exchange (ETDEWEB)

    Driscoll, C.M.H.; Green, B.M.R.; McKinlay, A.F.; Richards, D.J. (National Radiological Protection Board, Harwell (UK))

    1984-01-01

    The National Radiological Protection Board is involved in a large scale environmental survey of radiation levels in homes throughout the United Kingdom. Passive radon and gamma ray dosemeters are posted to a representative sample of households. Lithium fluoride thermoluminescence dosemeters are used to assess natural gamma radiation and are left in the measurement location for a period of six months before being returned to the Board for processing. As a preliminary to the national survey, the Board has been engaged on several limited surveys in regions of igneous and sedimentary geology. Experience gained in these limited surveys and from standardisation studies using environmental dosemeters are reported.

  16. Active electronic personal dosemeter in interventional radiology

    International Nuclear Information System (INIS)

    Prlic, I.; Suric Mihic, M.; Vucic, Z.

    2008-01-01

    A recently developed active electronic personal dosemeter (AEPD) was utilised in order to measure the levels and the structure of occupational exposure to scattered X-ray radiation of medical staff who performed percutaneous revascularisation therapy that involves interventional radiology (IR) on the pelvis and upper leg arteries. The AEPDs, placed on the operators' and assistants' chests, that is, above the protective apron, continuously measured and recorded the received doses and, as a novelty, dose rates as a function of time, thus yielding a unique record of occupational doses and dose rates pattern at the working place. This paper presents and discusses one typical daily pattern in which seven percutaneous interventions were performed. (authors)

  17. Calibration of Far West Technology (FWT-60) radiachromic dye dosemeters

    International Nuclear Information System (INIS)

    Mincher, B.J.; Zaidi, M.K.

    1992-01-01

    Radiachromic dye dosimetry was used to measure kilogray doses absorbed by various liquid samples during gamma-ray exposure in a spent nuclear fuel pool. The source of nuclear fuel was the Advanced Test Reactor (ATR) at the Idaho National Engineering Laboratory (INEL). Calibrations were performed using a 60 Co source and were run on bare dosemeters, as well as on dosemeters which mocked to simulate the samples. These dosemeters were prepared as a dye-impregnated nylon film and are commercially available. When exposed to gamma-ray doses of 0.5 to 200 kGy, a color change occurs which has an optical density proportional to absorbed dose. The difference in the calibration curves demonstrated the importance of irradiation of dosemeters under conditions as close to the actual samples as possible. Since these dosemeters could not be immersed directly in the organic solutions of interest, they were sandwiched between layers of lucite and stainless steel. This simulated the conditions inside an irradiated sample and provides a practical method of measuring absorbed doses. The reproducibility of measurements using the radiachromic dye dosemeters is also shown. 10 refs

  18. A CR-39 track dosemeter for routine individual neutron monitoring

    International Nuclear Information System (INIS)

    Luszik-Bhadra, M.; Alberts, W.G.; Dietz, E.; Guldbakke, S.; Matzke, M.; d'Errico, F.

    1994-01-01

    A personal neutron dosemeter for routine individual monitoring is proposed. It is based on a CR-39 track detector covered on three separate areas by converters with different boron contents and inserted into a commercial TLD albedo dosemeter capsule. The dose readings from three areas of the electrochemically etched CR-39 detector are combined to yield a dose equivalent response which is almost independent of the incident neutron energy in the range from thermal neutrons up to 20 MeV. In addition, the dose contributions of thermal, intermediate and fast neutrons can be determined separately. Unlike the TLD albedo dosemeter, which in general requires prior in-field calibration and whose use is then restricted to that field, this dosemeter can be used in neutron fields without any knowledge of the spectral distribution with the same calibration factor. The angular dependence of the dosemeter's response has been measured and compared with that of the directional dose equivalent H'(10). The lower limit of detection is 0.15 mSv. It is possible to obtain an independent, second dose reading from the same Cr-39 detector for neutron energies above 100 keV. The dosemeter has also been successfully tested for use in accident dosimetry applying chemical etching and an optical density reading of the CR-39 detector. (author)

  19. Optical readout method for solid-state dosemeters

    International Nuclear Information System (INIS)

    McDonald, J.C.; Eichner, F.N.; Stahl, K.A.; Miller, S.D.

    1986-07-01

    The readout of solid-state dosemeters is usually accomplished by heating to produce thermoluminescence. This technique has several disadvantages including stressing the dosemeter crystals, melting Teflon enclosures, and destroying the thin dosemeters designed for beta particle measurements. An optical readout method is being developed to avoid these difficulties. Standard dosemeters were irradiated to a dose of approximately 0.02 Sv with 137 Cs gamma rays. The dosemeters were then irradiated with light produced by a high-intensity xenon lamp. Various wavelength bands, from the ultraviolet through the visible and to the near-infrared, were used. The degree of trap emptying was found to be proportional to the total optical power incident. With the intensities used in the preliminary experiments, over 90% trap emptying was achieved. This new technique will prove useful for dosemeters that are encased in plastic for automatic processing. The details of this optical readout method, along with some possible applications in neutron and beta dosimetry are described. 7 refs., 3 figs

  20. Calibration of clinical dosemeters in the IAEA water phantom

    International Nuclear Information System (INIS)

    Caldas, L.V.E.; Albuquerque, M.P.P.

    1994-01-01

    The procedures recommended by the IAEA Code of Practice were applied at the Calibration Laboratory of Sao Paulo in order to provide in the future the clinical dosemeters users with absorbed dose to water calibration factors for Cobalt 60 radiation beams. In this work the clinical dosemeters were calibrated free in air and in water, and the results were compared, using conversion factors. The several tested clinical dosemeters of different manufacturers and models belong to the laboratory and to hospitals. For the measurements in water the IAEA cubic water phantom was used. The dosemeters were all calibrated free in air in terms of air kerma, and the calibration factors in terms of absorbed dose to water were obtained through conversion factors. the same dosemeters were also calibrated into the water phantom. Good agreement was found between the two methods, the differences were always less than 0.5%. The data obtained during this work show that when the dosemeters are used only in Cobalt 60 radiation and the users apply in the hospital routine work the IAEA Code of Practice, the calibration can be performed directly in the water phantom. This procedure provides the useful calibration factors in terms of absorbed dose to water

  1. Intercomparison of Environmental Dosemeters Using Various TL Materials and Dosimetry Systems

    International Nuclear Information System (INIS)

    Crnic, B.; Gobec, S.; Zorko, B.; Knezevic, Z.; Majer, M.; Ranogajec-Komor, M.

    2013-01-01

    The aim of the present work was to compare the ambient dose equivalent (H*(10)) values determined at 20 sites around NPP Krško, using different thermoluminescence (TL) materials and various dosimetry systems. The H*(10) was measured by the CaF 2 :Mn (TLD-400) provided by the Jozef Stefan Institute (JSI) Ljubljana, Slovenia. These dosemeters were deployed in the environment in plastic bags and suspended inside the plastic bottles. On the other hand the Ruder Boskovic Institute (RBI), Zagreb, Croatia applied LiF:Mg,Cu,P (TLD-100H), CaF 2 :Mn, Al 2 O 3 :C TL detectors and radiophotoluminescence (RPL) glass dosemeters type SG1. They were placed at the same locations in as much as possible same conditions as JSI detectors. According to the protocol established for this intercomparison, the control and transport detectors (not deployed in the environment) were held in dark storage containers and used to determine the background radiation. The TL responses were corrected for individual sensitivity of the TL detectors which is an important factor after the calibration irradiations. The calibration irradiations were performed by 137Cs sources provided in Secondary Standard Dosimetry Laboratory facilities at the JSI and RBI. The results obtained by different TL materials and different dosimetry systems show interesting features especially concerning local environmental peculiarities. The H*(10) obtained by the dosemeters of various types deployed in the countryside fluctuate less than 10 %. The outcome should emphasize also in the manner that the results obtained and reported in the intercomparison are traceable to the primary standards.(author)

  2. Prediction analysis of dose equivalent responses of neutron dosemeters used at a MOX fuel facility

    International Nuclear Information System (INIS)

    Tsujimura, N.; Yoshida, T.; Takada, C.

    2011-01-01

    To predict how accurately neutron dosemeters can measure the neutron dose equivalent (rate) in MOX fuel fabrication facility work environments, the dose equivalent responses of neutron dosemeters were calculated by the spectral folding method. The dosemeters selected included two types of personal dosemeter, namely a thermoluminescent albedo neutron dosemeter and an electronic neutron dosemeter, three moderator-based neutron survey meters, and one special instrument called an H p (10) monitor. The calculations revealed the energy dependences of the responses expected within the entire range of neutron spectral variations observed in neutron fields at workplaces. (authors)

  3. Evaluation of personal dosemeters and comparative measurements performed by PTB in the years 1979 through 1984. Pt. 1

    International Nuclear Information System (INIS)

    Boehm, J.; Buchholz, G.

    1986-01-01

    Comparison measurements of the official individual dosemeters performed in the PTB from 1979 to 1984 are described. Also a number of other, unofficial individual dosemeters participated. The performance of the comparison measurements and the types of the individual dosemeters are described. Tables show the values measured with the film dosemeters, with film and TLD dosemeters, and TLD dosemeters as well as dosimetric probes for whole-body and partial body dose measurement. (DG) [de

  4. Development of radiophotometric dosemeters of high sensitivity using plastic scintillators as light intensifiers

    International Nuclear Information System (INIS)

    Mesquita, C.H. de; Hamada, M.M.

    1987-01-01

    The use of rectangular plates of plastic scintillators as film holders in conventional photographic dosemeters is reported. The efficiency of their use as light converters for increase the sensitivity of these dosemeters are studied. (M.A.C.) [pt

  5. A passive radon dosemeter suitable for workplaces

    International Nuclear Information System (INIS)

    Orlando, C.; Orlando, P.; Patrizii, L.; Tommasino, L.; Tonnarini, S.; Trevisi, R.; Viola, P.

    2002-01-01

    The results obtained in different international intercomparisons on passive radon monitors have been analysed with the aim of identifying a suitable radon monitoring device for workplaces. From this analysis, the passive radon device, first developed for personal dosimetry in mines by the National Radiation Protection Board, UK (NRPB), has shown the most suitable set of characteristics. This radon monitor consists of a diffusion chamber, made of conductive plastic with less than 2 cm height, containing a CR-39 film (Columbia Resin 1939), as track detector. Radon detectors in workplaces may be exposed only during the working hours, thus requiring the storage of the detectors in low-radon zones when not exposed. This paper describes how this problem can be solved. Since track detectors are also efficient neutron dosemeters, care should be taken when radon monitors are used in workplaces, where they may be exposed to neutrons, such as on high altitude mountains, in the surroundings of high energy X ray facilities (where neutrons are produced by (gamma, n) reactions) or around high energy particle accelerators. To this end, the response of these passive radon monitors to high energy neutron fields has been investigated. (author)

  6. Radiofrequency detection by bubble dosemeter technology

    International Nuclear Information System (INIS)

    Olsen, R.G.

    1990-01-01

    In an initial attempt to utilise solid state dosimetric technology for non-ionizing radiation, planar bubble type detectors were irradiated with microwave energy at 2.38 GHz. Individual devices were produced as thin discs (8 cm diam. x 0.6 cm) rather than in the normal test-tube configuration. Both aqueous and non-aqueous-based devices were exposed to plane-wave irradiation inside a microwave anechoic chamber at power densities ranging from 40 to 80 mW.cm -2 . Specific absorption rate (SAR) in the disc shaped devices was thermometrically determined with the aid of a non-perturbing temperature probe and was approximately 0.3 (W.kg -1 )(mW.cm -2 ). Results showed the irradiation-induced bubble response to be relatively uniform in both types of devices, but the sensitivity was lower than that needed in a practical microwave dosemeter. We believe that improved sensitivity will be obtained by adding materials with a high microwave absorption cross section. (author)

  7. Improvement of the calibration technique of clinical dosemeters

    International Nuclear Information System (INIS)

    Ehlin Caldas, L.V.

    1988-08-01

    Clinical dosemeters constituted of ionization chambers connected to electrometers are usually calibrated as whole systems in appropriate radiation fields against secondary standard dosemeters in calibration laboratories. This work reports on a technique of component calibration procedures separately for chambers and electrometers applied in the calibration laboratory of IPEN-CNEN, Brazil. For electrometer calibration, redundancy was established by using a standard capacitor of 1000pF (General Radio, USA) and a standard current source based on air ionization with Sr 90 (PTW, Germany). The results from both methods applied to several electrometers of clinical dosemeters agreed within 0.4%. The calibration factors for the respective chambers were determined by intercomparing their response to the response of a certified calibrated chamber in a Co 60 calibration beam using a Keithley electrometer type 617. Overall calibration factors compared with the product of the respective component calibration factors for the tested dosemeters showed an agreement better than 0.7%. This deviation has to be considered with regard to an uncertainty of 2.5% in routine calibration of clinical dosemeters. Calibration by components permits to calibrate ionization chambers one at a time for those hospitals who have several ionization chambers but only one electrometer (small hospitals, hospitals in developing countries). 6 refs, 2 figs, 2 tabs

  8. Characterization of the personal thermoluminescent dosemeter of LiF: Mg, Ti + Ptfe

    International Nuclear Information System (INIS)

    Azorin N, J.; Gutierrez C, A.; Gonzalez M, P.

    1991-01-01

    The objective of this work is to characterize the thermoluminescent dosemeters taken place in the laboratory in form of pellets of LiF: Mg, Ti + Ptfe like personal dosemeters, subjecting them to the operation tests proposed by the international standards and comparing them with the TLD-100, the Tl dosemeter more used at the moment for personal dosimetry

  9. Application of chemical dosemeters during the irradiation of agricultural products

    Energy Technology Data Exchange (ETDEWEB)

    Kovacs, A; Stenger, V; Foeldiak, G [Magyar Tudomanyos Akademia, Budapest. Izotopintezete

    1983-09-01

    The joint recommedation by the FAO, WHO and IAEA in 1981 proposed the unrestricted permission of food irradiation under the dose value of 10 kGy (1 Mrd). The chemical dosemeters presented in the paper cover the dose range of 30 Gy to 1 MGy for use to food irradiation safety measurements. The Fricke dosemeter was used in the 50-400 Gy range at radappertization operations of onion, poppy and potato. The alcoholic chlorobenzene dosemeter with oscillometric analysis was applied successfully at low (0.4-4 kGy) ranges, primarily for irradiation dose monitoring of fruits, vegetables, refrigerated poultry etc. The conductometry could be used for dosimetry in the range of 60 Gy to 1 MGy.

  10. Dosimetric of extremities with Dosemeters thermoluminescent in Cuba

    International Nuclear Information System (INIS)

    Molina Perez, D.; Diaz Bernal, E.; Vera Alonso, L.

    1998-01-01

    From final of the year 1995 in the CPHR implement the service of monitoring of the extremities using Dosemeter thermoluminescent (TL). The dosemeter consists on a metallic ring with a circular hole where a detector of LiF:Mg,Ti is placed (model JR1152C) of 5x5x0.9 mm 3 , covered by a fine layer of polyethylene. In the work the characteristic dosimetric as of the dosemeter is studied it satisfies the main requirements for their use in the monitoring from the exhibition to radiation photonic of the extremities. The doses are also presented registered during the first two years of operation of the service. The results obtained until the moment point out to you practice them of nuclear medicine, radiotherapy and production of substances radioactive how as of more contribution

  11. Elaboration And Study Of Transfer Alanine/ESR Dosemeters

    International Nuclear Information System (INIS)

    Torres G, Luz A.

    1996-01-01

    The dosimetry is the dose measure imparted by the energy from the ionizing radiation to the matter. The dosemeters is the means used for the determination of such a dose. Diverse dosimetric classes exist, this classification depends in essence of the energy involved in the irradiation process and of its application necessity. It is as well as in radiological protection movie dosemeter is used, and TLD, in the calibration of units, as those of cobalt, the ionization cameras are used, in the detection of superficial contamination the accountants Geiger Muller and proportional etc. The transfer dosimeter Alanine/ESR is used, object of the present work, is characterized because after reading the registered dose, the information is conserved and it can be transferred and read in any team of ESR. Likewise the following dose that is imparted will be added to the previous one registered, this indicates that the dosemeters is of integral character. In the spectra taken ESR, it is determined that the integral double or area under the curve of the spectrum ESR is proportional to the concentration of free radicals generated by the radiation ionization and in turn this concentration is proportional to the dose received by the pills; in last, these proportionality relationships take to that the area under the curve of the spectrum main ESR is proportional to the radiation dose received by the alanine dosemeters. This dosemeter seeks to be an economic alternative that it will lend the calibration service that today offers the ionization Cameras or the acrylic red industrial dosemeters

  12. Australian participation in international intercomparisons of environmental dosemeters

    International Nuclear Information System (INIS)

    Boas, J.F.; David, R.C.; Jones, J.

    2002-01-01

    The Environmental Measurements Laboratory of the U.S. Department of Energy has conducted international intercomparisons of environmental dosemeters at regular intervals since 1974. This paper reports the results obtained in the 10th and 11th intercomparisons by JFB and JGY at the Australian Radiation Laboratory (in 1992 and 1996 respectively) and in the 12th intercomparison by JFB and DRCT at the Australian Radiation Protection and Nuclear Safety Agency and by JGY and JJ at Australian Radiation Serviceces during 2000 and 2001. The ARL/ARPANSA measurements used a simple dosemeter holder containing two CaSO 4 :Dy impregnated Teflon discs, one unshielded and the other shielded by approximately 2.4 mm of Cu. The ARS measurements used a commercially available TLD badge case containing a CaSO 4 :Dy impregnated Teflon card. The commercial badge case was not symmetrical in design. The filtration in the front and rear sections of the commercial badge case varied from an open area to an area shielded by copper, tin and cadmium. The results obtained were generally within ±15% of the reference values measured by EML using high-pressure ionisation chambers for dosemeters exposed hi the field to environmental radiation and for dosemeters given a single exposure to 137 Cs or 241 Am at EML or an associated laboratory. Similar agreement was obtained for dosemeters exposed in the field and also given a single exposure to 137 Cs radiation. In order to obtain this measure of agreement, the dosemeters were individually calibrated and the readouts corrected for fading. Copyright (2002) Australasian Radiation Protection Society Inc

  13. Validation of response simulation methodology of Albedo dosemeter

    International Nuclear Information System (INIS)

    Freitas, B.M.; Silva, A.X. da

    2016-01-01

    The Instituto de Radioprotecao e Dosimetria developed and runs a neutron TLD albedo individual monitoring service. To optimize the dose calculation algorithm and to infer new calibration factors, the response of this dosemeter was simulated. In order to validate this employed methodology, it was applied in the simulation of the problem of the QUADOS (Quality Assurance of Computational Tools for Dosimetry) intercomparison, aimed to evaluate dosimetric problems, one being to calculate the response of a generic albedo dosemeter. The obtained results were compared with those of other modeling and the reference one, with good agreements. (author)

  14. Using signal ''KVANT-1'' direct-reading dosemeter for the purposes of personnel monitoring

    International Nuclear Information System (INIS)

    Glinskij, G.A.; Karasev, V.S.; Mukhin, I.E.; Chumak, V.K.

    1977-01-01

    Presented is the description of ''KVANT-1'' dosemeter for monitoring personnel doses of gamma and X radiation. The dosemeter permits to judge on the radiation intensity, to control directly the dose being accumulated, to store the reading of the dose accumulated for a necessary period of time, to obtain sound signal in case of reaching the limit of a pre-set dose. Presented are a general view, block diagram, and the discription of the dosemeter desing and operation. Advantages of the ''KVANT-1'' dosemeter are shown as compared with the conventional personnel monitoring IFK-2,3 and KID-2 dosemeters [ru

  15. The influence of the energy distribution of workplace fields on neutron personal dosemeter reading

    International Nuclear Information System (INIS)

    Tanner, R.J.; Thomas, D.J.; Bartlett, D.T.; Hager, L.G.; Horwood, N.A.

    2002-01-01

    Variations in the energy dependence of response of neutron personal dosemeters cause systematic errors in the readings obtained in workplace fields. The magnitude of these errors has been determined theoretically by folding measured and calculated workplace energy distributions with dosemeter response functions, to determine the response of a given personal dosemeter in that field. These results have been analysed with consideration of the dosemeter response to various calibration spectra, and with reference to different workplaces. The dosemeters in the study are discussed in terms of the workplaces for which they can be suitably calibrated. Deficiencies in the published neutron energy distributions are identified

  16. The evaluation of multi-element personal dosemeters using the linear programming method

    International Nuclear Information System (INIS)

    Kragh, P.; Ambrosi, P.; Boehm, J.; Hilgers, G.

    1996-01-01

    Multi-element dosemeters are frequently used in individual monitoring. Each element can be regarded as an individual dosemeter with its own individual dose measurement value. In general, the individual dose values of one dosemeter vary according to the exposure conditions, i. e. the energy and angle of incidence of the radiation. The (final) dose measurement value of the personal dosemeter is calculated from the individual dose values by means of an evaluation algorithm. The best possible dose value, i.e. that of the smallest systematic (type B) uncertainty if the exposure conditions are changed in the dosemeter's rated range of use, is obtained by the method of linear programming. (author)

  17. Mensuration of equivalent dose with personal dosemeters and instruments of radiological protection in the new operative magnitudes ICRU, for external fields of beta radiation. Part I. Study of the homogeneity of the response personal dosemeters leaves (cards G-1, TLD-100), in radiation fields of Co60

    International Nuclear Information System (INIS)

    Alvarez R, J.T.

    1994-01-01

    without personal dosemeters, and for the bottom readings and sensibility of the reader equipment; and of the adjustment kindness to the normal for each game of data.The main conclusions that they were derived of this study they are: i.That the reader equipment presents differences statistically significant (α=5%) in their sensibilities; that which is necessary correct the readings of the dosemeter, making stand out the necessity of building the curves of operation of the equipment for the bottom and the sensibility. ii. The filter of A1 is not equivalent among the different personal dosemeters i i.For this sample of 40 cards with personal dosemeters to the one fewer exist: eleven populations different statistic significant, (α) to the response glass 1 five for the response of the glass 2, respectively. i v. That exist difference significant statistical, (α =5%) among the repetitions; what implies that it is necessary to control but strictly the experimental parameters to the one moment of carrying out the irradiations, (field size, correction for time of obturator of the source, distances source-detecting, etc), since the influence of the reader equipment it has already been considered. (Author)

  18. EURADOS intercomparisons on whole body and extremity dosemeters (2008–2009) – Results and comparison of different dosemeter designs

    International Nuclear Information System (INIS)

    Stadtmann, H.; Grimbergen, T.W.M.; Figel, M.; Romero, A.M.; Mcwhan, A.F.

    2011-01-01

    The EURADOS (European Radiation Dosimetry Group) working group (WG2) on Harmonisation of Individual Monitoring in Europe has shown that intercomparisons are fundamental for harmonisation of individual monitoring. As a result of these considerations, EURADOS started to prepare a series of continuous intercomparisons for individual monitoring services (IMS) in Europe. EURADOS has now successfully executed two intercomparison exercises, one for whole body dosemeters (2008) and one for extremity dosemeters (2009). Both exercises were performed without external funding, all costs being covered by the participants’ fees. More than 120 (!) different – mainly passive – dosimetry systems were tested from all over Europe until now and the results were analysed and compared. Although scientific studies were not the primary objective of these exercises specific additional information about the tested systems supplied by the participants for statistical analysis allows a detailed analysis of these results with respect to different parameters like dosemeter type, detector material, filter thickness or others design parameters. The influence of such parameters on the response values of the dosemeters is analysed and discussed in this paper. Both energy response as well as directional response for beta and photon radiation are considered. The influence of different design parameters e.g. detector material, is analysed by comparing the frequency distribution of the response values for different dosemeter groups. Pronounced differences for different detector materials (LiF:Mg,Ti, LiF:Mg,Cu,P and Li 2 B 4 O 7 /CaSO 4 ) were found. The paper gives a comprehensive overview on the performance of various European dosimetry services and the influence of the dosemeter design on the resulting response values.

  19. Radiological environmental monitoring with LiF-700-H dosemeters

    International Nuclear Information System (INIS)

    Scarnichia, E.; Levanon, I.; Andres, P.; Miani, C.; Ramirez, S.

    2011-10-01

    Since 2008 a radiological environmental monitoring with LiF-700-H has been carried out as a result of increasing the Ra-6 research reactor core power. The information obtained is used to evaluate and to quantify analytically the air kerma rate, the fading and the associated uncertainty by developing software tools (deconvolution and uncertainty algorithms). LiF-700-H dosemeters were chosen because of their high sensitivity to low air kerma rates. They show a very good stability and a negligible fading for two-month working periods. The air kerma rate detection limit (based on the 3σ criterion) during these working periods is about 0.4 n Gy/h. Air kerma rates of about 70 n Gy/h are measured with this detection limit. Following the Nist guidelines, an algorithm was developed in order to find the associated uncertainty. It considers several aspects, such as the source activity decay, distance source-dosemeter during the calibration procedure, irradiation time, calibration factor, dosemeter readout, dosemeter sensitivity, TLD reader stability and fading. The associated uncertainty is found to be about 25% for a 95% confidence interval (k = 2.025), which can be considered acceptable when taking into account the very low air kerma rates estimated. The LiF-700-H response to different energies and its relationship with climate changes over the calendar year are planned as future tasks. (Author)

  20. Graphite mixed magnesium borate TL dosemeters for beta ray dosimetry

    DEFF Research Database (Denmark)

    Prokic, M; Christensen, Poul

    1984-01-01

    Sintered MgB4O7:Dy dosemeters with graphite contents from 1 to 10% were investigated for application for personnel dosimetry. Data are given on dose response, dose threshold, reproducibility, beta energy response and fading. Furthermore, results from practical field experiments are presented...

  1. Viability of the Fricke dosemeter doped with methylene blue

    International Nuclear Information System (INIS)

    Souza, V.L.B.; Santos, C.D.A.; Rodrigues, K.R.G.; Cunha, M.S.; Figueiredo, M.D.C.; Melo, R.T.

    2009-01-01

    This work aims to find the possible utilization of the Fricke dosemeter doped with methylene blue (FMB) for the dosimetry of photodynamic therapy. The FMB was irradiated wit X rays and light emitted diodes demonstrating positive answers to the stimulus, being probably to be used for dosimetric objectives

  2. About the measurements systems with pen and thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Cortes I, M.E.; Ramirez G, F.P.

    1998-01-01

    In this work it is presented dosimetric data obtained with pen and thermoluminescent dosemeters, which are used by the Occupational Exposure Personnel (OEP) of the Mexican Petroleum Institute (IMP)(1). It was marked several great characteristics as for example, the differences among units which use one and another dosemeter type. Likewise, it is given to know diverse problems that were had in the IMP at relating the data obtained with these dosemeters (which utilizes OEP) and the ICRP 60 recommendations 1990. One of the most important difficulties is to satisfy the recommended limits by ICRP, particularly those that are referring to the units and their complex calculations. With respect to the unities, the ICRP makes reference at the concepts 'dose equivalent' and 'effective dose' with the sievert unit, that the General Regulations for Radiological Safety associates with 'dose equivalent' and 'effective dose equivalent'. It was illustrated the type of dosimetric statistics which are obtained with the TLD lectures and a OEP pen dosemeter during 1997. (Author)

  3. The right choice: extremity dosemeter for different radiation fields

    International Nuclear Information System (INIS)

    Brasik, N.; Stadtmann, H.; Kindl, P.

    2005-01-01

    Full text: Measurements of weakly penetrating radiation in personal dosimetry present problems in the design of suitable detectors and in the interpretation of their readings. For the measurement of the individual beta radiation dose, personal dosemeter for the fingers/tips are required. In general, the dosemeters currently used for personal monitoring of beta and low energy photon doses suffer from an energy threshold problem because the detector and/or the filter are too thick. TLDs of a standard thickness can seriously underestimate personal skin doses, especially in external fields of weakly penetrating radiation fields. LiF:Mg, Cu, P is a promising TL material which allows the production of thin detectors with sufficient sensitivity. Dosimetric properties of two different types of extremity dosemeters, designed to measure the personal dose equivalent Hp(0.07), have been compared: LiF:Mg, Ti (TLD100) and LiF:Mg, Cu, P (TLD700H). The first one consists of 100 mg.cm -2 LiF:Mg, Ti (TLD 100) chip and a 35mg. cm -2 cap, the other consists of a 7mg. cm -2 layer of LiF:Mg, Cu, P (TLD-700H) powder and a 5mg. cm -2 cap. The evaluation was done in two steps: performance tests (ISO-12794) and measurements in real workplaces. In the first step type test results for beta calibration were compared. In addition calibration for low energy photon radiation according to ISO 4037-3 was carried out. In the second step, simultaneous measurements with both types of dosemeters were performed at workplaces, where radiopharmaceuticals containing different radioisotopes are prepared and applied. Practices in these fields are characterized by handling of high activities at very small distances between source and skin. The results from the comparison of the two dosemeter types are presented and analyzed with respect to different radiation fields. Experiments showed a satisfactory sensitivity for the thinner dosemeter (TLD 700H) for detecting beta radiation at protection levels and a good

  4. Fiber-optic-coupled dosemeter for remote optical sensing of radiation

    International Nuclear Information System (INIS)

    Justus, B.L.; Huston, A.L.

    1996-01-01

    Remote sensing technologies for the detection and measurement of ionizing radiation exposure are of current interest for applications such as patient dose verification during radiotherapy and the monitoring of environmental contaminants. Fiberoptic-based sensing is attractive due to the advantages of small size, low cost, long life and freedom from electromagnetic interference. Several fiberoptic-based radiation sensing systems have been described that utilize radiation induced changes in the optical characteristics of the fiber such as reduced transmission as a result of darkening of the glass, optical phase shifts due to heating, or changes in the birefringence of a polarization-maintaining fiber. The measurement of radiation induced darkening is limited in both sensitivity and dynamic range and requires long fiber lengths. Phase shift measurements require the use of single-mode lasers, phase sensitive interferometric detection, long fiber lengths and complex signal processing techniques. Alternatively, thermoluminescent (TL) phosphor powders have been coated onto fiberoptic cables and remote dosimetry measurements performed using traditional laser heating techniques. The sensitivity is limited by the requirement for a very thin layer of phosphor material, due to problems associated with light scattering and efficient heating by thermal diffusion. In this paper we report the development of an all-optical, fiber-optic-coupled, thermoluminescence dosemeter for remote radiation sensing that offers significant advantages compared to previous technologies. We recently reported the development of an optically transparent, TL glass material having exceptionally good characteristics for traditional dosimetry applications. We also reported a modified TL glass incorporating a rare earth ion dopant in order to absorb light from a semiconductor laser and utilize the absorbed light energy to internally heat the glass and release the trapped electrons. (author)

  5. Evaluation of BICRON NE MCP DXT-RAD passive extremity dosemeter

    CERN Document Server

    Yuen, P S; Frketich, G; Rotunda, J

    1999-01-01

    Passive extremity dosemeters currently used in dosimetry communities worldwide have shortcomings. In general, an extremity dosemeter has too thick a detector element, and the dosemeter response is highly energy dependent for beta rays with energies ranging from 200 keV to 2 MeV. It often does not have dosemeter identification, causing problems in the chain of custody. It is often read manually, rendering reading/packing operations very labour intensive. As a result of collaboration between AECL and BICRON NE, a new extremity dosemeter, incorporating a highly sensitive LiF:Mg,Cu,P TLD and tentatively code named MCP DXT-RAD, was developed. It has been evaluated for radiological performance against an ISO draft standard for extremity dosemeters in twelve categories: homogeneity, detection threshold, beta ray energy response, beta angular response, photon energy response, photon angular response, reproducibility, stability under various climatic conditions, linearity, residue, self irradiation, and effect of ligh...

  6. Calibration of a scintillation dosemeter for beta rays using an extrapolation ionization chamber

    International Nuclear Information System (INIS)

    Hakanen, A.T.; Sipilae, P.M.; Kosunen, A.

    2004-01-01

    A scintillation dosemeter is calibrated for 90 Sr/ 90 Y beta rays from an ophthalmic applicator, using an extrapolation ionization chamber as a reference instrument. The calibration factor for the scintillation dosemeter agrees with that given by the manufacturer of the dosemeter within ca. 2%. The estimated overall uncertainty of the present calibration is ca. 6% (2 sd). A calibrated beta-ray ophthalmic applicator can be used as a reference source for further calibrations performed in the laboratory or in the hospital

  7. Characteristic of the dosemeter used by the service of film dosimetry in the CPHR

    International Nuclear Information System (INIS)

    Capote Ferrera, E.A.; Diaz Bernal, E.; Manzano de Armas, J.F.

    1998-01-01

    Characteristic of the dosemeter used by the service of dosimetria filmica of the CPHR.The use of film dosemeter brings I get the aquisition first it gives data that it includes its evaluation regarding the calibration magnitude and second the interpretation of these data in terms of the magnitude of personal dose, such as the equivalent dose (ICRU 47) or to the effective dose (ICRP 60). presently work the results of the study of the characteristics of the dosemeters are picked up

  8. Thermoluminescence sensitivity variations in LiF PTFE dosemeters incurred by improper handling procedures

    CERN Document Server

    Mason, E W; MacKinlay, Alistair F; Saunders, D

    1975-01-01

    A systematic study of some anomalous darkening effects and thermoluminescence sensitivity variations observed in LiF:PTFE thermoluminescent dosemeters is described. Various likely causes of such effects have been investigated. The manufacturer's recommended cleaning procedures have been found to be inadequate and, in some cases, have been found to actually promote discolouration of the dosemeters. Recommendations are given for the successful use of LiF:PTFE thermoluminescent dosemeters in personal dosimetry.

  9. C-program LINOP for the evaluation of film dosemeters by linear optimization. User manual

    International Nuclear Information System (INIS)

    Kragh, P.

    1995-11-01

    Linear programming results in an optimal measuring value for film dosemeters. The Linop program was developed to be used for linear programming. The program permits the evaluation and control of film dosemeters and of all other multi-component dosemeters. This user manual for the Linop program contains the source program, a description of the program and installation and use instructions. The data sets with programs and examples are available upon request. (orig.) [de

  10. Solid thermoluminescent dosemeter of sodium tetraborate and brazilian fluorite sensible to thermic neutrons

    International Nuclear Information System (INIS)

    Fratin, L.; Cruz, M.T. da

    1987-01-01

    The production of solid thermoluminescent dosemeters sensible to thermic neutrons is described. The stages of the production are described: vitrification of sodium tetraborate, mixture and cold pressing, syntherization. The obtention of a CaF 2 : natural dosemeter with NaCl which presents sensibility to gamma radiation similar to CaF 2 : natural dosemeter with Na 2 B 4 O 7 is studied. (M.A.C.) [pt

  11. Thermoluminescent dosemeters of CaSO4: Dy + Teflon

    International Nuclear Information System (INIS)

    Campos, L.L.

    1989-01-01

    The development of a pellet dosemeter of CaSO 4 : Dy + Teflon at the Dosimetric Materials Production Laboratory - IPEN/Brazilian CNEN-SP is presented. The pellets were produced by cold pressing and sintering a mixture of CaSO 4 : Dy and Teflon powders. The pellet characteristics from the point of view of dosimetry. A filter combination providing an energy independent response from 20 KeV to 1,25 MeV was obtained. The dosemeter consists of three pellets sealed between two thin plastic sheets and placed under plastic and lead filters. The combination of these three filters allows to determine the energy of an unknown source. (author) [pt

  12. CaSO4: Dy + Teflon thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Campos, L.L.

    1986-01-01

    A pellet dosemeter of CaSO 4 : Dy + Teflon was developed at IPEN. CaSO 4 : Dy thermoluminescent phosphor, grown in the Dosimetric Materials Production Laboratory was chosen, due to its high sensitivity, ease of preparation and comparatively low cost. Pellets were produced by cold pressing and sintering a mixture of CaSO 4 : Dy and Teflon powders. Extensive work was done to study in detail all CaSO 4 : Dy pellets characteristics from the point of view of dosimetry with the purpose of introducing it in the routine use. A filter combination providing an energy independent response from 20 KeV to 1,25 MeV was obtained. The dosemeter consists of three pellets sealed between two thin plastic sheets and placed under plastic and lead filters. The combination of these tree filters allows the exposure as well as the energy determination of an unknown source. (Author) [pt

  13. Re-assessment of dose from the Vinten extremity dosemeter

    International Nuclear Information System (INIS)

    O'Hagan, J.B.; Pearson, A.J.; Dutt, J.C.

    1989-01-01

    A procedure is described for re-assessing the dose from the Vinten extremity dosemeter using phototransferred thermoluminescence. The technique produces a linear response up to 50 Sv. The re-assessment efficiency is approximately 10% for the first re-assessment and 3-5% for the second re-assessment. The detection threshold values (at the 95% confidence level) are 3 mSv and 9 mSv respectively. (author)

  14. Automated read-out of thermoluminescence dosemeters in a centralized individual monitoring service

    International Nuclear Information System (INIS)

    Toivonen, M.

    The organizational problems in maintaining centralized individual monitoring service with erasable and re-usable dosemeters are evaluated. Design criteria for an automated thermoluminescence reader are laid down. It is characteristic for the planning of the monitoring system that the issuing of dosemeters can be arranged without having two dosemeters for each worker. A home made reader designed to fullfil these criteria is presented. The use of a standard barcode and a standard optical barcode reader in identification of dosemeters is described. A method of using a minicomputer in preparing the self-fastening identification labels, in printing mailing lists and in printing results is described

  15. Application of beta transmission for quality assurance of TLD tape dosemeters

    Energy Technology Data Exchange (ETDEWEB)

    Nagpal, J.S.; Gupta, S.K.; Supe, S.J. (Bhabha Atomic Research Centre, Bombay (India). Div. of Radiological Protection)

    1993-03-01

    Transmission of [sup 204]Tl [beta] radiation enables measurement of differences of [+-] 2 mg/cm[sup 2] in thermoluminescent tape dosemeter thickness. This thickness variation gives rise to a maximum variation of [+-] 5% in the TL output per unit area of the dosemeters. Measurements of [beta] transmission on dosemeter samples drawn from several batches of skived tape as well as those prepared by compressing technique have given consistent results. The [beta] transmission method itself can be used for quality assurance and selection of a uniform set of dosemeters over thickness range 30-150 mg/cm[sup 2]. (author).

  16. Official dosimetry with individual electronic dosemeters - the concept in Germany

    International Nuclear Information System (INIS)

    Czarwinski, R.; Kaulard, J.; Pfeffer, W.

    2005-01-01

    Full text: Presently, in Germany passive dosemeters (film batches, RPL, TLD) are used for the official individual monitoring of occupational exposed personal. The application of electronic individual dosemeters (EPD) is carried out mainly for the operative radiation protection control particularly in nuclear power engineering companies, big hospitals und research centres. This means in such institutions double monitoring exists - legally and operatively. A crucial advantage of EPD compared to passive dosemeter is the possibility to adapt the monitoring period to the working time in the control area, e.g. a job related monitoring is available. Germany started a project for an optimized implementation of EPD into the official dosimetry. Objective of the project whose results will be described in the paper is the harmonization of radiation protection of companies workers and outside workers concerning the record of individual and job related exposures. The approval of the EPD by the Federal and Laender authorities as an official dosimetric system demands the implementation of special requirements concerning the data acquisition, data transfer and data evaluation. These issues are focuses of the Federal research project, supervised by the Federal Office for Radiation Protection (BfS) and performed by the Gesellschaft fuer Anlagen- und Reaktorsicherheit (GRS), Cologne to develop a concept in the first stage. (author)

  17. Micro-dosemeter instrument (MIDN) for assessing risk in space

    International Nuclear Information System (INIS)

    Pisacane, V. L.; Dolecek, Q. E.; Malak, H.; Cucinotta, F. A.; Zaider, M.; Rosenfeld, A. B.; Rusek, A.; Sivertz, M.; Dicello, J. F.

    2011-01-01

    Radiation in space generally produces higher dose rates than that on the Earth's surface, and contributions from primary galactic and solar events increase with altitude within the magnetosphere. Presently, no personnel monitor is available to astronauts for real-time monitoring of dose, radiation quality and regulatory risk. This group is developing a prototypic instrument for use in an unknown, time-varying radiation field. This micro-dosemeter-dosemeter nucleon instrument is for use in a space-suit, spacecraft, remote rover and other applications. It provides absorbed dose, dose rate and dose equivalent in real time so that action can be taken to reduce exposure. Such a system has applications in health physics, anti-terrorism and radiation-hardening of electronics as well. The space system is described and results of ground-based studies are presented and compared with predictions of transport codes. An early prototype in 2007 was successfully launched, the only solid-state micro-dosemeter to have flown in space. Published by Oxford Univ. Press on behalf of the US Government 2011. (authors)

  18. On the calibration of radiotherapy dosemeters in Australia

    International Nuclear Information System (INIS)

    Huntley, R.; Kotler, L.; Webb, D.

    2000-01-01

    Full text: Dosemeters for external beam radiotherapy are calibrated in Australia by ARPANSA, against the national primary standards of exposure and absorbed dose. The primary standards are free air chambers for exposure at low and medium energy X-rays, a graphite cavity chamber for exposure at 60 Co, and a graphite calorimeter for absorbed dose at 60 Co and high energy (MV) X -rays. Radiotherapy dosemeters are calibrated against these standards using a well documented formalism to provide calibration factors suitable for use with dosimetry protocols. A dosemeter usually comprises an ionization chamber connected to an independent electrometer. These are calibrated separately if possible. A combined calibration factor is reported together with the electrometer calibration factor (sensitivity). The dosimetry protocol used in radiotherapy centres in Australia and New Zealand is currently the simplified version of the IAEA TRS277 protocol, published by the New Zealand NRL and recommended by the ACPSEM. This protocol requires the use of an exposure or air kerma calibration factor at 60 Co (Nx or Nk) to evaluate the absorbed dose to air calibration factor N D . The chamber is then placed in a water phantom with its centre displaced from the reference point by p eff . ARPANSA can also supply calibration factors in absorbed dose to water (N D,w ), as required as input to the new IAEA CoP. If an absorbed dose to water calibration factor is used by the radiotherapy centre, the chamber should be placed with its centre at the reference point in the water phantom. ARPANSA has for some years coordinated the participation of Australian radiotherapy centres in the IAEA TLD Quality Audit service. Note that this service does not represent a calibration and should not be referred to as such. The only calibration is that provided by ARPANSA for a reference dosemeter at each radiotherapy centre. As soon as the ANSTO SSDL is operational, calibrations of reference dosemeters will also be

  19. Systematic processing of the external individual monitoring data obtained by photographic film and capacitor dosemeters

    International Nuclear Information System (INIS)

    Krueger, F.; Shtuk, D.

    1983-01-01

    Individual radiation load measurements have been carried out both with photographic film and capacitor type dosemeters (CD). Systematic statistics methods were applied for the obtained data processing. The CD data were shown to exceed those measured with the film dosemeters. Specific features of the CD application are revealed that should be taken into account in practice [ru

  20. Development of radiophotometric dosemeters with high sensitivity using plastic scintillators as a light intensifier

    International Nuclear Information System (INIS)

    Mesquita, C.H. de; Hamada, M.M.

    1987-01-01

    Rectangular plates of plastic scintillators are developed and their effect as light converter evaluated, when used as film-holder in conventional photography dosemeters. In this dosemeter, the radiation that not interacts in the photographic film can be detected by light photons generation in the plastic scintillators, sensitizing the film. (C.G.C.) [pt

  1. Verification of Ca F2:Mn type of dosemeters for personal dosimetry purposes

    International Nuclear Information System (INIS)

    Misovic, M.; Boskovic, Z.; Spasic-Jokic, V.

    1995-01-01

    Verification results of CaF2:Mn type of dosemeters for personal dosimetry purposes are presented in this paper. Tree types of irradiations are proceeded due to verification of relevant features of TLD. It is concluded that mentioned type of dosemeter can be used for purpose of personal dosimetry. (author)

  2. Electron scattering effects on absorbed dose measurements with LiF-dosemeters

    International Nuclear Information System (INIS)

    Bertilsson, G.

    1975-10-01

    The investigation deals with absorbed dose measurements with solid wall-less dosemeters. Electron scattering complicates both measurement of absorbed dose and its theoretical interpretation. The introduction of the dosemeter in a medium causes perturbations of the radiation field. This perturbation and its effect on the distribution of the absorbed dose inside the dosemeter is studied. Plane-parallel LiF-teflon dosemeters (0.005 - 0.1 g.cm -2 ) are irradiated by a photon beam ( 137 Cs) in different media. The investigation shows that corrections must be made for perturbations caused by electron scattering phenomena. Correction factors are given for use in accurate absorbed dose determinations with thermoluminescent dosemeters. (Auth.)

  3. Dose equivalent response of personal neutron dosemeters as a function of angle

    International Nuclear Information System (INIS)

    Tanner, J.E.; McDonald, J.C.; Stewart, R.D.; Wernli, C.

    1997-01-01

    The measured and calculated dose equivalent response as a function of angle has been examined for an albedo-type thermoluminescence dosemeter (TLD) that was exposed to unmoderated and D 2 O-moderated 252 Cf neutron sources while mounted on a 40 x 40 15 cm 3 polymethylmethacrylate phantom. The dosemeter used in this study is similar to many neutron personal dosemeters currently in use. The detailed construction of the dosemeter was modelled, and the dose equivalent response was calculated, using the MCNP code. Good agreement was found between the measured and calculated values of the relative dose equivalent angular response for the TLD albedo dosemeter. The relative dose equivalent angular response was also compared with the values of directional and personal dose equivalent as a function of angle published by Siebert and Schuhmacher. (author)

  4. Development and testing of a thermoluminescent dosemeter for mixed neutron-photon-beta radiation fields

    International Nuclear Information System (INIS)

    Zummo, J.J.; Liu, J.C.

    1998-08-01

    A new four-element thermoluminescent (TL) dosemeter and dose evaluation algorithm have been developed and tested to better characterize personnel exposure in mixed neutron-photon-beta radiation fields. The prototype dosemeter is based on a commercially available TL card (with three LiF-7 chips and one LiF-6 chip) and modified filtration elements. The new algorithm takes advantage of the high temperature peak characteristics of the LiF-6 element to better quantify the neutron dose component. The dosemeter was tested in various radiation fields, consisting of mixtures of two radiation types typically used for dosemeter performance testing, as well as mixtures of three radiation types to simulate possible exposure conditions. The new dosemeter gave superior performance, based on the tolerance levels, when using the new algorithm as compared to a conventional algorithm that did not use the high temperature peak methodology. The limitations and further improvements are discussed

  5. Neutron dosemeter responses in workplace fields and the implications of using realistic neutron calibration fields

    International Nuclear Information System (INIS)

    Thomas, D.J.; Horwood, N.; Taylor, G.C.

    1999-01-01

    The use of realistic neutron calibration fields to overcome some of the problems associated with the response functions of presently available dosemeters, both area survey instruments and personal dosemeters, has been investigated. Realistic calibration fields have spectra which, compared to conventional radionuclide source based calibration fields, more closely match those of the workplace fields in which dosemeters are used. Monte Carlo simulations were performed to identify laboratory systems which would produce appropriate workplace-like calibration fields. A detailed analysis was then undertaken of the predicted under- and over-responses of dosemeters in a wide selection of measured workplace field spectra assuming calibration in a selection of calibration fields. These included both conventional radionuclide source calibration fields, and also several proposed realistic calibration fields. The present state of the art for dosemeter performance, and the possibilities of improving accuracy by using realistic calibration fields are both presented. (author)

  6. Method of making isodose curve using thermoluminescence dosemeter

    International Nuclear Information System (INIS)

    Bakar Ramain, A.

    1975-01-01

    Line source of 60 Co in the form of needles and tubes are extensively used in radiotherapy in moulds, implants, and intracavitary techniques for the treatment of malignant lesions. It is important to have isodose distributions in tissue for those source for purposes of treatment planning. The isodose distributions have been obtained experimentally by using tinny lithium-fluoride (Lsub(i)F) thermoluminescent dosemeters (TLD) and they are compared to the theoretical results. The distinct advantages of Lsub(i)F (TLD) in such measurements are briefly discussed. (author)

  7. Aluminium nitrate ceramics: A potential UV dosemeter material

    DEFF Research Database (Denmark)

    Trinkler, L.; Bøtter-Jensen, L.; Berzina, B.

    2002-01-01

    The ceramic material AIN-Y2O3 is proposed as a potential ultraviolet radiation (UVR) dosemeter using optically stimulated luminescence (OSL) and thermally stimulated luminescence (TL). Experimental studies have shown that AIN ceramics exhibit attractive characteristics suitable for practical UV...... dosimetry applications. The features are: (1) the spectral sensitivity covers the 200-350 nm range, in the UV-B region it is similar to that of human skin: (2) the angular dependence of the incident radiation follows the cosine law; (3) high yields of both UVR-induced OSL and TL signals compared to those...

  8. Results of the IAEA/RCA personal dosemeter intercomparison

    Energy Technology Data Exchange (ETDEWEB)

    Tsujimura, Norio; Momose, Takumaro; Hayashi, Naomi [Environment and Safety Division, Tokai Works, Japan Nuclear Cycle Development Inst., Tokai, Ibaraki (Japan)

    2000-06-01

    The intercomparison of personal dosemeters for photon was carried out between 1990 and 1996 as part of the IAEA/RCA 'strengthening of radiation protection infrastructure' project. Japan Nuclear Cycle Development Institute participated in the intercomparison as one of the in-house personal dosimetry service organizations in Japan and also served the host irradiating laboratory. This report summarizes the dose evaluation results obtained from the JNC-TLD badges in the past four intercomparison programs. In the latest intercomparison the evaluated doses agreed to the reference doses with an accuracy of 10%. (author)

  9. New KID dosemeter for measurement of cosmic dosimetry

    International Nuclear Information System (INIS)

    Peksova, D.; Kakona, M.; Krist, P.; Kocur, Z.; Larina, K. V.; Ploc, O.

    2018-01-01

    The KID dosemeter is a small semiconductor low-power detector developed for common use. The current design is special designed after measuring cosmic rays on aircraft decks. The design concept is the same world-class devices Internet of Things (IoT). As a detection element detector were tested three variants a) PIN HAMAMATSU S2744-09 photodiode, b) 9 parallel Vishay photodiodes TEMD5080X01, c) 16 Vishay photodiode TEMD5080X01 again in parallel connection. All variants are silicon PIN photodiode. (authors)

  10. Study of teflon pads as high doses dosemeters

    International Nuclear Information System (INIS)

    Teixeira, Maria Ines; Caldas, Linda V.E.

    2013-01-01

    The aim of this work is to study the Teflon, which is used as a binder in the manufacture of dosimetric tablets, for the feasibility of this material as high dose dosemeter. In this paper we used the technique of thermally stimulated luminescence (OSL) to characterize the dosimetric properties of Teflon. Teflon samples were exposed to different doses of radiation, using a source of gamma radiation ( 60 Co). It was obtained dose-response curve between 100 Gy to 50 kGy and reproducibility of OSL response. The preliminary results show that Teflon is a useful material to high dose dosimetry

  11. Type testing of the Siemens Plessey electronic personal dosemeter.

    Science.gov (United States)

    Hirning, C R; Yuen, P S

    1995-07-01

    This paper presents the results of a laboratory assessment of the performance of a new type of personal dosimeter, the Electronic Personal Dosemeter made by Siemens Plessey Controls Limited. Twenty pre-production dosimeters and a reader were purchased by Ontario Hydro for the assessment. Tests were performed on radiological performance, including reproducibility, accuracy, linearity, detection threshold, energy response, angular response, neutron response, and response time. There were also tests on the effects of a variety of environmental factors, such as temperature, humidity, pulsed magnetic and electric fields, low- and high-frequency electromagnetic fields, light exposure, drop impact, vibration, and splashing. Other characteristics that were tested were alarm volume, clip force, and battery life. The test results were compared with the relevant requirements of three standards: an Ontario Hydro standard for personal alarming dosimeters, an International Electrotechnical Commission draft standard for direct reading personal dose monitors, and an International Electrotechnical Commission standard for thermoluminescence dosimetry systems for personal monitoring. In general, the performance of the Electronic Personal Dosemeter was found to be quite acceptable: it met most of the relevant requirements of the three standards. However, the following deficiencies were found: slow response time; sensitivity to high-frequency electromagnetic fields; poor resistance to dropping; and an alarm that was not loud enough. In addition, the response of the electronic personal dosimeter to low-energy beta rays may be too low for some applications. Problems were experienced with the reliability of operation of the pre-production dosimeters used in these tests.

  12. A study of the irradiation temperature coefficient for L-alanine and DL-alanine dosemeters

    International Nuclear Information System (INIS)

    Desrosiers, M. F.; Lin, M.; Cooper, S. L.; Cui, Y.; Chen, K.

    2006-01-01

    Alanine dosimetry is now well established both as a reference and routine dosemeter for industrial irradiation processing. Accurate dosimetry under the relatively harsh conditions of industrial processing requires a characterisation of the parameters that influence the dosemeter response. The temperature of the dosemeter during irradiation is a difficult quantity to measure so that the accuracy of the temperature coefficient that governs the dosemeter response becomes a critical factor. Numerous publications have reported temperature coefficients for several types of alanine dosemeters. The observed differences in the measured values were commonly attributed to the differences in the polymer binder or the experimental design of the measurement. However, the data demonstrated a consistent difference in the temperature coefficients between L-alanine and DL-alanine. Since there were no commonalities in the dosemeter composition or the measurement methods applied, a clear conclusion is not possible. To resolve this issue, the two isomeric forms of alanine dosemeters were prepared and irradiated in an identical manner. The results indicated that the DL-alanine temperature coefficient is more than 50% higher than the L-alanine temperature coefficient. (authors)

  13. Understanding differences in dose-equivalents reported by passive and electronic personal dosemeters

    International Nuclear Information System (INIS)

    Perks, Christopher A.; Burgess, Peter; Smith, David; Salasky, Mark; Yahnke, Cliff

    2008-01-01

    Full text: In a number of challenging environments, clients occasionally double badge with electronic personal dosemeters (EPDs) to ensure day-to-day management of their employees personal dose-equivalent while using passive (in our case Luxel or InLight) dosemeters for monthly monitoring for approved results for dose record keeping. In some cases there have been significant differences in the cumulative doses recorded by the EPDs and the passive dosemeters. In these circumstances the passive dosemeters usually report a higher dose than the EPD by up to a factor of two, though more commonly 1.3. In this paper we describe the differences seen between EPD and passive dosemeters (in a number of countries). We then examine the possible causes for such discrepancies by comparison with published response function data available for the EPDs and Landauer dosemeters. We have undertaken a number of experiments comparing directly a number of EPDs and passive dosemeter response to a variety of energy and complex angular geometries where the two types of dosimeter have been exposed at the same time. Recommendations will be made on the appropriate use of double badging in difficult environments and interpretation of the results. (author)

  14. Individual TL detector characteristics in automated processing of personnel dosemeters: correction factors as extension to identity codes of dosemeter cards

    International Nuclear Information System (INIS)

    Toivonen, Matti.

    1979-07-01

    One, two and three-component dosemeter cards and their associated processing equipment were developed for personnel monitoring. A novel feature of the TLD system is that the individual sensitivity correction factors of TL detectors for β/γ radiation dosimetry and special timing factors for the readout of neutron detectors are stored on dosemeter cards as an extension of the identity codes. These data are utilized in the automatic TL reading process with the aim of cancelling out the influence of the individual detector characteristics on the measuring results. Stimulation of TL is done with hot nitrogen without removing the detectors from their cards and without any metal contact. Changes in detector characteristics are thus improbable. The reading process can be adjusted in a variety of ways. For example, each detector in the same card can be processed with optimal heating and the specific 250 deg C glow peak of neutron radiation can be roughly separated from the main LiF glow peaks. (author)

  15. Measurements of environmental gamma-ray spectra using a multi-element TL dosemeter

    International Nuclear Information System (INIS)

    Furuta, Sadaaki; Boetter-Jensen, L.; Nielsen, S.P.

    1986-12-01

    A method to estimate the energy distribution and dose of environmental gamma radiation was developed using a multielement TL dosemeter. Experimentally obtained energy responses from a multi-element TL dosemeter with different kinds of filters were used to calculate the energy distribution and related dose by the SAND-II computer code. The code was originally developed to estimate the neutron flux using a multiple foil activation method. Measurements were made at several locations with the multi-element TL dosemeter and comparisons were made with results from a NaI(Tl) scintillation detector and a high-pressure ionization chamber. (author)

  16. The use of active personal dosemeters as a personal monitoring device: Comparison with TL dosimetry

    International Nuclear Information System (INIS)

    Boziari, A.; Koukorava, C.; Carinou, E.; Hourdakis, C. J.; Kamenopoulou, V.

    2011-01-01

    The use of active personal dosemeters (APDs) not only as a warning device but also, in some cases, as an official and hence stand-alone dosemeter is rapidly increasing. A comparison in terms of dose, energy and angle dependence, among different types of APD and a routinely used whole-body thermoluminescence dosemeter (TLD) has been performed. Significant differences were found between the TLD readings and mainly some not commonly used APDs. The importance of choosing the best adapted APD according to the radiation field characteristics is pointed out. (authors)

  17. A gamma/neutron-discriminating, Cooled, Optically Stimulated Luminescence (COSL) dosemeter

    International Nuclear Information System (INIS)

    Eschbach, P.A.; Miller, S.D.

    1992-07-01

    The Cooled Optically Stimulated Luminescence (COSL) of CaF 2 :Mn (grain sizes from 0.1 to 100 microns) powder embedded in a hydrogenous matrix is reported as a function of fast-neutron dose. When all the CaF 2 :Mn grains are interrogated at once, the COSL plastic dosemeters have a minimum detectable limit of 1 cSv fast neutrons; the gamma component from the bare 252 cf exposure was determined with a separate dosemeter. We report here on a proton-recoil-based dosemeter that generates pulse height spectra, much like the scintillator of Hornyak, (2) to provide information on both the neutron and gamma dose

  18. Dosimetric characteristics of a TLD dosemeter with extremities; Caracteristicas dosimetricas de un dosimetro TLD de extremidades

    Energy Technology Data Exchange (ETDEWEB)

    Molina P, D.; Diaz B, E.; Lien V, R. [Centro de Proteccion e Higiene de las Radiaciones, CPHR, Apdo.Postal 6195, Habana 6, CP 10600, Ciudad Habana (Cuba)

    1999-07-01

    It was designed a TLD dosemeter for the monitoring of the extremities. This one consists in a metallic ring with a circular orifice where is arranged a T L detector of LiF: Mg,Ti (Model JR1152C) 5 x 5 x 0.8 mm{sup 3} covered by a polyethylene fine layer. In this work were studied the dosimetric properties of the dosemeter for its application in the dosimetry of extremities for photonic radiation. the results obtained allow conclude that the designed dosemeter can be used for the extremities monitoring. (Author)

  19. Mensuration of equivalent dose with personal dosemeters and instruments of radiological protection in the new operative quantities ICRU, for external fields of beta radiation. Part II. I study of the angular response of personal dosemeters TLD-100 in secondary patron fields of beta radiation (90Sr / 90Y)

    International Nuclear Information System (INIS)

    Alvarez R, J.T.

    1994-01-01

    The objective of this work is to carry out one of the possible ones test type for personal dosemeters TLD, under the recomendations of the ICRU 39, ICRU 43 and the draft of the norm ISO 6980,(1992), with the purpose of verifying the capacity of these detectors to carry out the operative unit: H' (0.07;α). Since H' (O. 07;α) this defined one in an expanded field, one of these tests type consist on determining the angular response of these detectors. 20 personal dosemeters TLD-100 was used, (card marks: Harshaw, Model: G-1, with two glasses of TLD-100 absorbed in teflon; the portadosemeters has two windows, a free one and another with a filter of Pb of 171.0 mg cm -2 ); these dosemeters they were previously selected, [to see, S tudy of the Homogeneity of the response of Personal Dosemeters (Cards G-l, TLD-100) in Radiation of Countrysides of 60 Co , J.T. Alvarez R. Technician Report GSR/IT/0001/94].The irradiations to effectued in secondary countryside of radiation beta of 90 Sr/ 90 Y. The study was undertaken by means of an experimental design of blocks random that contemplate the following variables: intensity of the radiation source, (1850 MBq and 74 MBq); position of irradiation, (four positions); incidence of angle of the radiation (0, 15, 30, 45, 60 and 75 grades) and the absorbed dose in air, (0.005, 0.010, 0.020, 0.050 and 0.100 Gy). Then null hypothesis it was to suppose that there was not difference among the stockings of each treatment, to used the statistical of Duncan to carry out tests of stockings at a level of significance of 5%.These tests of stockings throw the following results in those variables of the experimental design: The irradiations carried out so much with the source pattern secondary of 90 Sr/ 90 Y of 1850 MBq and of 74 MBq, they are equivalent reason why they can be used indistinctly. The responses of each one of the glasses of the card are strongly anisotropic for each glass; four positions of irradiation is used: glass 1 (window of

  20. Thermoluminescent dosemeter in a X-ray diffractometer

    International Nuclear Information System (INIS)

    Mendoza A, D.; Gonzalez M, P.; Falcon B, T.; Castano, V.M.

    1999-01-01

    In this work it was presented the results obtained of the dosimetry which was realized in a X-ray diffractometer for powders, trademark Siemens D5000, using the thermoluminescent signal generated by the X-rays in the commercial dosemeter TLD-100 of Harshaw, US. In according to the results obtained, the radiation quantity received by an analysed material in the diffractometer, will be proportional to exposure time and it can vary from unities until tenths of grays. These results are very outstanding when are analysed crystalline materials in a diffractometer, for knowing the present crystalline phases, mainly if these are highly sensitive to the ionizing radiation, as it is the case of the thermoluminescent materials. (Author)

  1. Use of active dosemeters as a optimization tool in hemodynamics

    International Nuclear Information System (INIS)

    Nunes, Rafael; Pereira, Dirceu D.; Rodrigues, Barbara B.D.; Ferreira, Esmeralci

    2016-01-01

    Interventional cardiology procedures are, in general, associated with high doses in patients and professionals. The objective of this study is to measure the radiation levels received by professionals .The professional dosimetry was performed in a department of Hemodynamics of University Hospital in Rio de Janeiro. were followed 331 coronary angiography (CA) and 26 percutaneous transluminal coronary angioplasty (PTCA) procedures. For this, were used active dosemeters to measure the radiation levels at the chest of interventional professionals. The results show that average personal equivalent dose of doctors, per procedure was 100 e 154 μSv. On average, nursing technicians and radiologist receive 12 and 10% of doses of physicians, respectively, during CA procedures. From the results, it appears that the doses of hemodynamics exceed the annual dose limit of the standards. The use of lead shielding is presented as an effective action to reduce doses in these workers. (author)

  2. The role of phantom parameters on the response of the AEOI Neutriran Albedo Neutron Personnel Dosemeter

    International Nuclear Information System (INIS)

    Sohrabi, M.; Katouzi, M.

    1992-01-01

    The response of the AEOI Neutriran Albedo Neutron Personnel Dosemeter (NANPD) which can also be used for other albedo dosemeter types was determined on 18 different phantom configurations. The effects of type, geometry, material, thickness, dosemeter-to-phantom angle in particular with the presence of legs were investigated using a Pu-Be neutron source. It was concluded that the slab phantoms (single or double) and circular and elliptical cylinder phantoms seemed to provide a better response, whereas the ICRU sphere geometry does not seem to be appropriate for the calibration of albedo dosemeters. It is interesting to note that the presence of legs maintains the constancy of the response in a situation when a radiation worker bends down during work. (author)

  3. TL response of LiF: Mg, Cu, P dosemeters in function of the photon energy

    International Nuclear Information System (INIS)

    Gonzalez, P.R.; Azorin, J.; Furetta, C.

    2005-01-01

    In this work the obtained results of studying the response of dosemeters of LiF: Mg, Cu, P + Ptfe, developed in the ININ, commercial dosemeters GR200A (LiF: Mg, Cu, P) of chinese manufacture and TLD-100 (LiF: Mg, Ti) US are presented, when irradiating them with X rays 16, 24, 34.5, 42, 100 and 145 keV of effective energy, with gamma rays of 662 keV ( 137 Cs) and 1252 keV ( 60 Co). The results are presented in function of the sensitivity that the dosemeters showed normalized to gamma radiation of 60 Co. It was appreciated that the dosemeters more equivalent to the tissue, they were those of LiF: Mg, Cu, P + Ptfe, while the less equivalent ones were the TLD-100. (Author)

  4. Calibration of thermoluminescence skin dosemeter response to beta emitters found in Ontario Hydro nuclear power stations

    International Nuclear Information System (INIS)

    Walsh, M.L.; Agnew, D.A.; Donnelly, K.E.

    1984-01-01

    The response of the Ontario Hydro Thermoluminescence Dosimetry System to beta radiation in nuclear power station environments was evaluated. Synthetic beta spectra were constructed, based on activity samples from heat transport systems and fuelling machine contamination smears at nuclear power stations. Using these spectra and dosemeter energy response functions, an overall response factor for the skin dosemeter relative to skin dose at 7 mg.cm -2 was calculated. This calculation was done assuming three specific geometries: (1) an infinite uniformly contaminated plane source at a distance of 33 cm (50 mg.cm -2 total shielding) from the receptor; (2) an infinite cloud surrounding the receptor; (3) a point source at 33 cm. Based on these calculations, a conservative response factor of 0.7 has been chosen. This provides an equation for skin dose assignment, i.e. Skin Dose = 1.4 x Skin Dosemeter Reading when the skin dosemeter is directly calibrated in mGy(gamma). (author)

  5. Personal neutron dosemeter of the Czech Republic: Review of basic properties, results of recent tests

    Czech Academy of Sciences Publication Activity Database

    Trousil, J.; Spurný, František; Plichta, J.

    2006-01-01

    Roč. 14, 7/8 (2006), s. 246-253 ISSN 1210-7085 Institutional research plan: CEZ:AV0Z10480505 Keywords : detectors * dosemeters * personal dosimetry Subject RIV: DN - Health Impact of the Environment Quality

  6. Conversion factors for the ICRU dose equivalent quantities for calibrating radiation dosemeters

    International Nuclear Information System (INIS)

    Grosswendt, B.; Hohlfeld, K.; Kramer, H.M.; Selbach, H.J.

    1985-02-01

    Report describing the application of conversion factors for monoenergetic photon radiation and for X and gamma reference radiation used for dosemeter calibration with the aid of spherical or rectangular phantoms (environmental and individual monitoring). (DG) [de

  7. Solid thermoluminescent dosemeter of sodium tetraborate and brazilian fluorite sensible to thermal neutrons

    International Nuclear Information System (INIS)

    Fratin, L.; Cruz, M.T. da

    1987-01-01

    A solid termoluminescent dosemeter of sodium tetraborate and brazilian fluorite sensible to thermal neutrons is described. The nuclears reactions 1) 10 B + n → 7 Li + He + Q1 (6,1%) where: Q1=2,79 MeV and Eα1 = 1,758 MeV and 2) 10 B + n → 7 Li* + 4 He + Q2 (93,9%) where: Q2 = 2,316 MeV and E2α 2 = 1,474 MeV are responsible by the thermoluminescent response of the thermal neutrons dosemeters. The stages in the fabrication process of this dosemeter of which are:1) sodium tetraborate vitrification, 2) mixture and pressing 3) sintering are cited. The obtainment of a natural fluorite dosemeter with sodium chloride is also shown. (C.G.C.) [pt

  8. Basic requirements of dosemeter systems for individual monitoring of external radiation

    International Nuclear Information System (INIS)

    Boehm, J.; Ambrosi, P.

    1985-01-01

    A plea is made for detailed detector independent requirements for dosemeter systems for individual monitoring of external radiation. These requirements should have their origin in the fundamental aspects and concepts of radiation protection for workers, and should be something like a translation of the general principles of individual monitoring into a language easily understandable by producers and users. This work comprises a summary of the general objectives of individual monitoring and discussion of some relevant requirements for dosemeter systems. (orig.) [de

  9. Eurados trial performance test for personal dosemeters for external beta radiation

    DEFF Research Database (Denmark)

    Christensen, P.; Bordy, J.M.; Ambrosi, P.

    2001-01-01

    On the initiative of the European Dosimetry Group (EURADOS) action group 'Harmonisation and Dosimetric Quality Assurance in Individual Monitoring for External Radiation' a trial performance test for whole-body and extremity personal dosemeters broadly representative of those in use in the EU...... the results obtained from the exercise. In particular, based on the replies to a questionnaire issued to each participant, the results are analysed in relation to important design characteristics of the dosemeters taking part in the test....

  10. Mensuration of equivalent dose with personal dosemeters and instruments of radiological protection in the new operative magnitudes ICRU, for external fields of beta radiation. Part I. Study of the homogeneity of the response personal dosemeters leaves (cards G-1, TLD-100), in radiation fields of Co{sub 60}; Medicion de dosis equivalente con dosimetros personales e instrumentos de proteccion radiologica en las nuevas magnitudes operativas ICRU, para campos de radiacion beta externos. Parte I. Estudio de la homogeneidad de la respuesta dosimetros personales (tarjetas G-1, TLD-100), en campos de radiacion de Co{sub 60}

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J.T. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1994-01-15

    and without personal dosemeters, and for the bottom readings and sensibility of the reader equipment; and of the adjustment kindness to the normal for each game of data.The main conclusions that they were derived of this study they are: i.That the reader equipment presents differences statistically significant ({alpha}=5%) in their sensibilities; that which is necessary correct the readings of the dosemeter, making stand out the necessity of building the curves of operation of the equipment for the bottom and the sensibility. ii. The filter of A1 is not equivalent among the different personal dosemeters i i.For this sample of 40 cards with personal dosemeters to the one fewer exist: eleven populations different statistic significant, ({alpha}) to the response glass 1 five for the response of the glass 2, respectively. i v. That exist difference significant statistical, ({alpha} =5%) among the repetitions; what implies that it is necessary to control but strictly the experimental parameters to the one moment of carrying out the irradiations, (field size, correction for time of obturator of the source, distances source-detecting, etc), since the influence of the reader equipment it has already been considered. (Author)

  11. Determination of isodose curves in Radiotherapy using an Alanine/ESR dosemeter

    International Nuclear Information System (INIS)

    Chen, F.; Baffa, O.; Graeff, C.F.O.

    1998-01-01

    It was studied the possible use of an Alanine/ESR dosemeter in the isodose curves mapping in normal treatments of Radiotherapy. It was manufactured a lot of 150 dosemeters with base in a mixture of D-L Alanine dust (80 %) and paraffin (20 %). Each dosemeter has 4.7 mm diameter and 12 mm length. A group of 100 dosemeters of the lot were arranged inside 50 holes of the slice 25 of the phantom Rando Man. The phantom irradiation was realized in two opposed projections (AP and PA) in Co-60 equipment. A group of 15 dosemeters was take of the same lot for obtaining the calibration curve in a 1-20 Gy range. After irradiation the signal of each dosemeter was measured in an ESR spectrometer operating in the X-band (∼ 9.5 GHz) and the wideness of Alanine ESR spectra central line was correlated with the radiation dose. The wideness dose calibration curve resulted linear with a correlation coefficient 0.9996. The isodose curves obtained show a profile enough similar at comparing with the theoretical curves. (Author)

  12. Feasibility study of extremity dosemeter based on polyallyl-diglycol-carbonate (CR-39) for neutron exposure

    International Nuclear Information System (INIS)

    Chau, Q.; Bruguier, P.

    2007-01-01

    In nuclear facilities, some activities such as reprocessing, recycling and production of bare fuel rods expose the workers to mixed neutron-photon fields. For several workplaces, particularly in glove boxes, some workers expose their hands to mixed fields. The mastery of the photon extremity dosimetry is relatively good, whereas the neutron dosimetry still raises difficulties. In this context, the Inst. for Radiological Protection and Nuclear Safety (IRSN) has proposed a study on a passive neutron extremity dosemeter based on chemically etched CR-39 (PADC: polyallyl-diglycol-carbonate), named PN-3, already used in routine practice for whole body dosimetry. This dosemeter is a chip of plastic sensitive to recoil protons. The chemical etching process amplifies the size of the impact. The reading system for tracks counting is composed of a microscope, a video camera and an image analyser. This system is combined with the dose evaluation algorithm. The performance of the dosemeter PN-3 has been largely studied and proved by several laboratories in terms of passive individual neutron dosemeter which is used in routine production by different companies. This study focuses on the sensitivity of the extremity dosemeter, as well as its performance in the function of the level of the neutron energy. The dosemeter was exposed to monoenergetic neutron fields in laboratory conditions and to mixed fields in glove boxes at workplaces. (authors)

  13. Measurement of gamma radiation doses at the RA reactor by thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Prokic, M.

    1974-01-01

    This paper presents the procedures and gamma radiation doses measured at the exit from the horizontal experimental channel HK-5, vertical experimental channel VK-5 and in the thermal column of the RA reactor in Vinca. Measurement of gamma radiation dose in the mixed intense gamma and neutron radiation field was done by two types of thermoluminescent dosemeters, LiF (TLD-700) and CaF 2 (TLD-08). Gamma dose in the VK-5 was measured in the air and on the bottle filled with tissue-equivalent solution. Increase of the dose on the surface of the bottle was 2.3 compared to the gamma dose value in the air. Correction for the influence of neutrons having different energies was done by using the known sensitivity values of both TL dosemeter types for thermal, intermediate and fast neutrons. Results showed that the TLD-700 dosemeter contains 5 time more Li-6 isotopes (0.035%) than the declared value causing increased neutron sensitivity of this dosemeter. This paper includes numerical sensitivity data for neutrons of different energies for both types of TL dosemeters. Neutron sensitivity values for TLD-700 are related to LiF with 0.035% of Li-6 isotope. Result of measurement have also shown that the CaF 2 :Mn (TLD-08) thermoluminescent dosemeter is more suitable for gamma radiation dose measurements in mixed n-gamma fields with intensive neutron fluxes due to lower neutron sensitivity compared to TLD-700 [sr

  14. Individual monitoring with official electronic dosemeters in Germany - concepts and reality

    International Nuclear Information System (INIS)

    Martini, E.; Wahl, W.; Huebner, S.; Freynhagen, D.; Staemmler, M.

    2005-01-01

    Full text: Active (electronic) personal dosemeters (APD) are radiometers, which are equipped as active or passive dosimeters. They can directly indicate a dose rate and/or the dose integrated during a certain period (direct-indicating, active electronic personal dosemeters mentioned) or only over a separate reader (direct-selectable, passive electronic personal dosemeters mentioned). A concept is presented for the use of passive or active electronic personal dosemeters in Germany as official dosemeters, e.g. in hospitals. The concept features a net-based approach for secure data communication between readers for passive and active electronic personal dosemeters und the official personal dosimetry monitoring service(s), taking the German policies (StrISchV und RoeV in hospitals) into account. The net-based solution includes a processor controlled interface via TCP/IP connected to the dosimetry reader(s), und reader interfaces, an official interim data bank and all the necessary equipment such as PC, Raid-configuration, USV support, network connection and further details. Investigations have been started to achieve highest-level data manipulation security, data completeness und data correctness. (author)

  15. Glass badge dosimetry system for large scale personal monitoring

    International Nuclear Information System (INIS)

    Norimichi Juto

    2002-01-01

    Glass Badge using silver activated phosphate glass dosemeter was specially developed for large scale personal monitoring. And dosimetry systems such as an automatic leader and a dose equipment calculation algorithm were developed at once to achieve reasonable personal monitoring. In large scale personal monitoring, both of precision for dosimetry and confidence for lot of personal data handling become very important. The silver activated phosphate glass dosemeter has basically excellent characteristics for dosimetry such as homogeneous and stable sensitivity, negligible fading and so on. Glass Badge was designed to measure 10 keV - 10 MeV range of photon. 300 keV - 3 MeV range of beta, and 0.025 eV - 15 MeV range of neutron by included SSNTD. And developed Glass Badge dosimetry system has not only these basic characteristics but also lot of features to keep good precision for dosimetry and data handling. In this presentation, features of Glass Badge dosimetry systems and examples for practical personal monitoring systems will be presented. (Author)

  16. How do hospital sterilisation procedures affect the response of personal extremity rings and of eye lens TL dosemeters?

    International Nuclear Information System (INIS)

    Kopec, Renata; Bubak, Anna; Budzanowski, Maciej; Sas-Bieniarz, Anna; Szumska, Agnieszka

    2016-01-01

    Stringent standards of hygiene must be applied in medical institutions, especially at operating blocks or during interventional radiology procedures. Medical equipment, including personal dosemeters that have to be worn by medical staff during such procedures, needs therefore to be sterilised. In this study, the effect of various sterilisation procedures has been tested on the dose response of extremity rings and of eye lens dosemeters in which thermoluminescent (TL) detectors (of types MTS-N and MCP-N, respectively) are used. The effects of medical sterilisation procedures were studied: by chemicals, by steam or by ultraviolet (UV), on the dose assessment by extremity rings and by eye lens dosemeters. Since it often happens that a dosemeter is accidentally machine-washed together with protective clothing, the effect of laundering on dose assessment by these dosemeters was also tested. The sterilisation by chemicals is mostly safe for TL detectors assuming that the dosemeters are waterproofed. Following sterilisation by water vapour, the response of these dosemeters diminished by some 30 %, irrespectively of the period of sterilisation; therefore, this method is not recommended. UV sterilisation can be applied to EYE-D TM eye lens dosemeters if their encapsulation is in black. The accidental dosemeter laundry in a washing machine has no impact on measured dose. (authors)

  17. HOW DO HOSPITAL STERILISATION PROCEDURES AFFECT THE RESPONSE OF PERSONAL EXTREMITY RINGS AND OF EYE LENS TL DOSEMETERS?

    Science.gov (United States)

    Kopeć, Renata; Bubak, Anna; Budzanowski, Maciej; Sas-Bieniarz, Anna; Szumska, Agnieszka

    2016-09-01

    Stringent standards of hygiene must be applied in medical institutions, especially at operating blocks or during interventional radiology procedures. Medical equipment, including personal dosemeters that have to be worn by medical staff during such procedures, needs therefore to be sterilised. In this study, the effect of various sterilisation procedures has been tested on the dose response of extremity rings and of eye lens dosemeters in which thermoluminescent (TL) detectors (of types MTS-N and MCP-N, respectively) are used. The effects of medical sterilisation procedures were studied: by chemicals, by steam or by ultraviolet (UV), on the dose assessment by extremity rings and by eye lens dosemeters. Since it often happens that a dosemeter is accidentally machine-washed together with protective clothing, the effect of laundering on dose assessment by these dosemeters was also tested. The sterilisation by chemicals is mostly safe for TL detectors assuming that the dosemeters are waterproofed. Following sterilisation by water vapour, the response of these dosemeters diminished by some 30 %, irrespectively of the period of sterilisation; therefore, this method is not recommended. UV sterilisation can be applied to EYE-D™ eye lens dosemeters if their encapsulation is in black. The accidental dosemeter laundry in a washing machine has no impact on measured dose. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Summary of personal neutron dosemeter results obtained within the EVIDOS project

    International Nuclear Information System (INIS)

    Luszik-Bhadra, M.; Reginatto, M.; Schuhmacher, H.; Bolognese-Milsztajn, T.; Lacoste, V.; Boschung, M.; Fiechtner, A.; Coeck, M.; Vanhavere, F.; Curzio, G.; Errico d', F.; Kylloenen, J.-E.; Lindborg, L.; Bartlett, D.; Tanner, R.

    2005-01-01

    Full text: Within the EC project EVIDOS ('Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields'), different types of neutron personal dosemeters were irradiated in workplace fields in nuclear installations in Europe. Mostly electronic personal neutron dosemeters were tested, among them commercial devices (Thermo Electron EPD-N, Aloka PDM-313), devices from first industrial prototype series (Thermo Electron EPD-N2, Saphydose-n) and laboratory prototypes which were already in the stage of lightweight battery-operated instruments (PTB DOS-2002). In addition, dosemeters with (almost) immediate readout (BTI bubble detectors, Rados DIS-N) and passive dosemeters which needed no fielddependent calibration factors (PADC track detectors from PSI and NRPB) were used, as well as those TLD albedo dosemeters which are routinely used in the facilities visited. The results of measurements obtained within the EVIDOS project in workplace fields in nuclear installations in Europe, i.e. at Kruemmel (boiling water reactor, transport cask), at Mol (Venus research reactor, fuel facility Belgonucleaire) and at Ringhals (pressurized water reactor, transport cask) are presented and compared to reference values of personal dose equivalent H p (10) determined by means of Bonner spheres and novel directional spectrometers. In fields with strong back-scatter and moderation of neutrons, several dosemeters showed overreadings by more than a factor of two. In strongly directed fields with neutron dose equivalent peaked at about 1 MeV (MOX fuel), the same dosemeters showed under-readings of about a factor of two. These under- and over-readings in the workplace fields can be explained in terms of the dosemeter response functions for mono-energetic neutrons, which show over-responses in the thermal and intermediate neutron energy region and under-responses at about 1 MeV neutron energy. The dosemeter readings obtained in the workplace fields were checked for consistency by

  19. Intercomparison of active personal dosemeters in interventional radiology

    International Nuclear Information System (INIS)

    Clairand, I.; Struelens, L.; Bordy, J. M.; Daures, J.; Debroas, J.; Denozieres, M.; Donadille, L.; Gouriou, J.; Itie, C.; Vaz, P.; D'Errico, F.

    2008-01-01

    The use of active personal dosemeters (APD) in interventional radiology was evaluated by Working Group 9 (Radiation protection dosimetry of medical staff) of the CONRAD project, which is a Coordination Action supported by the European Commission within its sixth Framework Programme. Interventional radiology procedures can be very complex and they can lead to relatively high doses to personnel who stand close to the primary radiation field and are mostly exposed to radiation scattered by the patient. For the adequate dosimetry of the scattered photons, APDs must be able to respond to low-energy [10-100 keV] and pulsed radiation with relatively high instantaneous dose rates. An intercomparison of five APD models deemed suitable for application in interventional radiology was organised in March 2007. The intercomparison used pulsed and continuous radiation beams, at CEA-LIST (Saclay (France)) and IRSN (Fontenay-aux-Roses (France)), respectively. A specific configuration, close to the clinical practice, was considered. The reference dose, in terms of Hp(10), was derived from air kerma measurements and from the measured and calculated energy distributions of the scattered radiation field. Additional Monte Carlo calculations were performed to investigate the energy spectra for different experimental conditions of the intercomparison. The results of this intercomparison are presented in this work and indicate which APDs are able to provide a correct response when used in the specific low-energy spectra and dose rates of pulsed X-rays encountered in interventional radiology. (authors)

  20. Proposal of a dosemeter for skin beta radiation dose assessment

    International Nuclear Information System (INIS)

    Rosa, L.A.R. da; Caldas, L.V.E.

    1987-08-01

    Beta radiation is, undoubtedly, less penetrating than X or gamma radiation. Thus, beta radiation sources external to the human body do not cause a significant irradiation of its deeper tissues. However, in some cases, they may contribute in a very important way to the irradiation of the lens of the eyes and, mainly, of the skin. Specially, the hands and finger tips may receive a high dose. In this work some relevant aspects of the individual monitoring in beta radiation fields are discussed and the importance of monitoring this kind of radiation in some activities where the skin absorbed dose may be a limiting factor is evidenced. The main characteristics of the thermoluminescent (TL) response of ultra-thin CaSO 4 : Dy detectors (UT-CaSO 4 : Dy) in the detection of this kind of radiation are also studied. The irradiation are performed with 90 Sr 90 Y, 204 TI and 147 Pm sources. The reproducibility, linearity, dependence on the absorbed dose rate, optical fading, energy and angular dependences of the detector TL responce are investigated. Transmission factors for different thicknesses of tissue equivalent material are obtained for the TL detectors using the three available beta sources. Based on the results obtained, a dosemeter for skin beta radiation absorbed dose assessment with an energy dependence better than 12% is proposed. (Author) [pt

  1. Calibration of extremity dosemeters for gamma radiation fields

    International Nuclear Information System (INIS)

    Papadopulos, S.B.; Gregori, B.N.; Cruzate, J.A.

    1998-01-01

    In this work the kerma conversion factor are free in air, dose equivalent H(d,0 ) are presented, they were obtained theoretical and experimentally in finger and arm for gamma radiation fields. Extremity dosemeters put on surface finger and arm phantom have been irradiated. The finger phantom is a solid cylinder of PMMA polymethylmethacrylate 19 mm diameter and 300 mm height. The arm phantom is a 73 mm external diameter cylinder with PMMA walls 2.5 mm thick fill with water and 300 mm height. The radiation sources were cobalt 60 and cesium 137 from the Regional Center of Reference (CRR) of the National Commission of Atomic Energy (CNEA) and the Nuclear Regulatory Authority (ARN). Also in ISO wide X ray spectra W60, W110 and W200 have been irradiated. The results obtained show a good correlation with those published, they have a difference less than 7%. The factors will be applied to the evaluation of the equivalent doses coming from workers whose main irradiated zone is in the hands. (author)

  2. Intercomparison program of personal dosemeters in the Argentine Republic

    International Nuclear Information System (INIS)

    Gregori, B.N.; Papadopulos, S.B.; Kunst, J.J.

    1998-01-01

    During 1997, under the auspices of the Nuclear Regulatory Authority (ARN), its was held the third exercise of intercomparison of laboratories of personal dosimetry. The dosemeters were irradiated in X-ray beams ISO quality W60, W110, W200 and gamma sources cesium 137 and cobalt 60. The irradiation were performed kerma free in air and in phantom in order to study the capacity to evaluate both conditions. An extent range of doses (low-high) have been given 0.3 mSv- 20mSv in order to determine the operative performance o each laboratory. Over 19 laboratories of Argentina, participated 13 (65%) and finished the intercomparison 12 (60%) of them. The systems of dosimetry detection were based on film and TLD. During this intercomparison as inquiry about several items related with the laboratories have been made. In this work are shown the individual laboratory results of the intercomparison related with the acceptance curve criteria ICRP 60 and 55. (author)

  3. Measurement of doses to aviator pilots using thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Azorin N, J.; Cruz C, D.; Rivera M, T.

    2004-01-01

    During the development of their work, the aviator pilots are exposed at high levels of natural radiation of bottom caused mainly by the cosmic radiation of galactic origin and lot. For such reason, the Metropolitan Autonomous University (UAM) and the Union Association of Aviator Pilots (ASPA), subscribed an agreement with the purpose of to measure the doses of ionizing radiation received by the aviator pilots of diverse air companies that man different types of airships and to determine if these doses surpass the one limit of 0.11 mSv/h settled down by the IAEA for the public in general; and if therefore, these workers should be considered as personnel occupationally exposed. In this work the obtained results when measuring the absorbed dose received by Mexican civil aviator pilots during the development of their work, using thermoluminescent dosemeters of LiF:Mg,Cu,P + Ptfe of national production are presented. The obtained results during the years of 2001 and 2002 show that the monthly doses received by the pilots surpass the one it limits established for the public in general, for what they should be considered as personnel occupationally exposed. (Author)

  4. Numerical and experimental results of the operational neutron dosemeter 'Saphydose-N'

    International Nuclear Information System (INIS)

    Lahaye, T.; Chau, Q.; Menard, S.; Ndontcheung-Moyo, M.; Bolognese-Milsztajn, T.; Rannou, A.

    2004-01-01

    Since 1993, the Inst. for Radiological Protection and Nuclear Safety (IRSN) has lead, in association with Electricite de France (EDF), a R and D study of a neutron personal electronic dosemeter. This dosemeter, called 'Saphydose-N', is manufactured by the SAPHYMO company. This paper presents first the optimisation of some detector components using Monte Carlo calculations, and second the test of the manufactured Saphydose-N under radiation following the IEC 1323 standard's recommendations for active personal neutron dosemeters. The measurements with the manufactured dosemeter were performed on the one hand at PTB (Physikalisch-Technische Bundesanstalt) in mono-energetic neutron fields and, on the other hand at IRSN in neutron fields generated by a thermal facility (SIGMA), radionuclide ISO sources and a realistic spectrum (CANEL/T400). The manufactured dosemeter Saphydose-N was also tested during measurement campaigns of the European programme EVIDOS ('Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields') at different nuclear workplaces. The study showed that Saphydose-N complies with the recommendations of standard IEC 1323 and can be used at any workplace with no previous knowledge of the neutron field characteristics. (authors)

  5. Energy and angular dependence of the personal dosemeter in use at ITN-DPRSN

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Joao G. [Departamento de Proteccao Radiologica e Seguranca Nuclear, Instituto Tecnologico e Nuclear, EN 10, 2686-953 Sacavem (Portugal)], E-mail: jgalves@itn.pt; Calado, Ana M.; Cardoso, Joao V.; Santos, Luis M. [Departamento de Proteccao Radiologica e Seguranca Nuclear, Instituto Tecnologico e Nuclear, EN 10, 2686-953 Sacavem (Portugal)

    2008-02-15

    In this paper the characterization of the dosimetry system and of the personal dosemeter in terms of the stability of the reader calibration factors and of the linearity of the response for the 137Cs reference radiation is presented. The energy and angular dependence of the whole body dosemeter are also shown. The energy dependence was determined performing irradiations with the X-ray narrow series beams N30, N40, N60, N80, N100, N120 and with the gamma reference radiations of 137Cs and 60Co [ISO 4037-1, 1996. X and Gamma Reference Radiation for Calibrating Dosemeters and Doserate Meters and for Determining Their Response as a Function of Photon Energy-Part 1: Radiation Characteristics and Production Methods. International Organization for Standardization, Geneva] in terms of Hp(10) incident on the ISO water slab phantom. The angular dependence of the dosemeter was determined for the angles 0 deg., {+-}20 deg., {+-}40 deg. and {+-}60 deg. with normal using the above mentioned radiation fields. All irradiations were performed at the Laboratorio de Metrologia das Radiacoes lonizantes of ITN-DPRSN. The experiments presented in this paper show the thermoluminescence dosimetry (TLD) system is stable and presents a linear behaviour over and extended dose range. The measurements allowed the determination of the energy dependence at normal incidence and of the angular dependence of the dosemeter currently in use. Further studies are being carried out in order to implement correction factors for supralinearity and low energy measurements.

  6. Use of digital dosemeters for supporting staff radiation safety in paediatric interventional radiology suites.

    Science.gov (United States)

    McNeil, Sarah M; Lai, Priscilla; Connolly, Bairbre L; Gordon, Christopher L

    2013-12-01

    Modern-day interventional radiology (IR) procedures impart a wide range of occupational radiation doses to team members. Unlike thermoluminescent badges, digital dosemeters provide real-time dose readings, making them ideal for identifying different components during IR procedures, which influence staff radiation safety. This study focused solely on paediatric IR (PIR) cases. Digital dosemeters measured the impact of imaging modality, shielding, patient and operator specific factors, on the radiation dose received during various simulated and real live PIR procedures. They recorded potential dose reductions of 10- to 100-fold to each staff member with appropriate use of shielding, choice of imaging method, staff position in the room and complex interplay of other factors. The digital dosemeters were well tolerated by staff. Results highlight some unique radiation safety challenges in PIR that arise from dose increases with magnification use and close proximity of staff to the X-ray beam.

  7. Use of digital dosemeters for supporting staff radiation safety in paediatric interventional radiology suites

    International Nuclear Information System (INIS)

    McNeil, S. M.; Lai, P.; Connolly, B. L.; Gordon, C. L.

    2013-01-01

    Modern-day interventional radiology (IR) procedures impart a wide range of occupational radiation doses to team members. Unlike thermoluminescent badges, digital dosemeters provide real-time dose readings, making them ideal for identifying different components during IR procedures, which influence staff radiation safety. This study focused solely on paediatric IR (PIR) cases. Digital dosemeters measured the impact of imaging modality, shielding, patient and operator specific factors, on the radiation dose received during various simulated and real live PIR procedures. They recorded potential dose reductions of 10-to 100-fold to each staff member with appropriate use of shielding, choice of imaging method, staff position in the room and complex interplay of other factors. The digital dosemeters were well tolerated by staff. Results highlight some unique radiation safety challenges in PIR that arise from dose increases with magnification use and close proximity of staff to the X-ray beam. (authors)

  8. The former tests realized to a personal neutron dosemeter based on solid nuclear tracks detector

    International Nuclear Information System (INIS)

    Camacho, M.E.; Tavera, L.; Balcazar, M.

    1997-01-01

    Due to the increase in the use of neutron radiation a personal neutron dosemeter based on solid nuclear tracks detector (DSTN) was designed and constructed. The personal dosemeter design consists of three arrangements. The first one consists of a plastic nuclear tracks detector (LR115 or CR39) in contact with a LiF pellet. The second one is the same that above but it placed among two cadmium pellets and, the third one is formed by the alone detector without converter neither neutron absorber. The three arrangements are placed inside a plastic porta detector hermetically closed to avoid the bottom produced by environmental radon whichever both detectors (LR115 and CR39) are sensitive. In this work the former tests realized to that dosemeter are presented. (Author)

  9. Measurements of eye lens doses in interventional cardiology using OSL and electronic dosemeters

    International Nuclear Information System (INIS)

    Sanchez, R.M.; Vano, E.; Fernandez, J.M.; Ginjaume, M.; Duch, M.A.

    2014-01-01

    The purpose of this paper is to test the appropriateness of OSL and electronic dosemeters to estimate eye lens doses at interventional cardiology environment. Using TLD as reference detectors, personal dose equivalent was measured in phantoms and during clinical procedures. For phantom measurements, OSL dose values resulted in an average difference of 215 % vs. TLD. Tests carried out with other electronic dosemeters revealed differences up to ±20 % versus TLD. With dosemeters positioned outside the goggles and when TLD doses were >20 μSv, the average difference OSL vs. TLD was 29 %. Eye lens doses of almost 700 μSv per procedure were measured in two cases out of a sample of 33 measurements in individual clinical procedures, thus showing the risk of high exposure to the lenses of the eye when protection rules are not followed. The differences found between OSL and TLD are acceptable for the purpose and range of doses measured in the survey (authors)

  10. Calibration of personal dosemeters in terms of the ICRU operational quantities

    International Nuclear Information System (INIS)

    McDonald, J.C.; Hertel, N.E.

    1992-05-01

    The International Commission on Radiological Units and Measurements (ICRU) has defined several new operational quantities for radiation protection purposes. The quantities to be used for personal monitoring are defined at depths in the human body. Because these quantities are impossible to measure directly, the ICRU has recommended that personal dosemeters should be calibrated under simplified conditions on an appropriate phantom, such as the ICRU sphere. The US personal dosimetry accreditation programs make use of a 30 x 30 x 15 cm polymethymethacrylate (PMMA) phantom, therefore it is necessary to relate the response of dosemeters calibrated on this phantom to the ICRU operational quantities. Calculations of the conversion factors to compute dosemeter response in terms of the operational quantities have been performed using the code MCNP. These calculations have also been compared to experimental measurements using thermoluminescent (TLD) detectors

  11. One year of a thermoluminescent dosemeter and dose record keeping service

    International Nuclear Information System (INIS)

    Dennis, J.A.

    1979-01-01

    A brief description is given of the National Radiological Protection Board's (NRPB) thermoluminescent dosemeter. The automated processing of these dosemeters is linked to a computer-based system of dose records. The postal system is currently used by about 10% of the establishments for which the NRPB provides a personnel monitoring service, but it will soon be extended to other establishments. The distributions of individual whole body doses in 1977 are tabulated. The significant advantage of this new system lies in the improvements in accuracy, completeness, and convenience to the employers of record keeping. (U.K.)

  12. Determination of the dose rapidity of a 90 Sr beta radiation source using thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Gonzalez M, P.R.; Azorin N, J.; Rivera M, T.

    2000-01-01

    The thermoluminescent dosemeters developed in Mexico, have been used efficiently in environmental and personal dosimetry. When the dose rate of some source is not known can be estimated with the use of thermoluminescent dosemeters taking in account the geometrical array used in the irradiations for reproducibility of the results in posterior irradiations. In this work it was estimated the dose rate of a 90 Sr- 90 Y beta radiation source which is property of the Nuclear Sciences Institute, UNAM, therefore it was l ended to the Metropolitan Autonomous University- Iztapalapa Unit for the characterization of new Tl materials, taking account of the institutional collaboration agreements. (Author)

  13. Use of bubbles dosemeters to measure the neutrons leakage radiations around a medical accelerator

    International Nuclear Information System (INIS)

    Bourgois, L.

    1999-01-01

    In this study, the neutron component has been determined on a medical accelerator (Saturne 43F type accelerator) with the help of bubbles detectors marketed by the Bubble Technology Industry society. BD-PND type dosemeters with sensitivities from 0.1 to 0.23 bubbles/micro sievert have been used. These dosemeters have important advantages: they are small enough and then, homogeneously irradiated, they are insensitive to intense electromagnetic fields and to photons and electrons, they can used several times by compression, the reading of the device does not need expensive means and it is possible to multiply the measure points. (N.C.)

  14. Glass sealing

    Energy Technology Data Exchange (ETDEWEB)

    Brow, R.K.; Kovacic, L.; Chambers, R.S. [Sandia National Labs., Albuquerque, NM (United States)

    1996-04-01

    Hernetic glass sealing technologies developed for weapons component applications can be utilized for the design and manufacture of fuel cells. Design and processing of of a seal are optimized through an integrated approach based on glass composition research, finite element analysis, and sealing process definition. Glass sealing procedures are selected to accommodate the limits imposed by glass composition and predicted calculations.

  15. Electrochromic Glasses.

    Science.gov (United States)

    1980-07-31

    this glass and that dipole-dipole correlations contribute to the "ferroelectric-like" character of this amorphous system. The TeO2 -W03 glasses can only...shows the dielectric constant and Fig. I(b) glass from pure TeO2 ot pure WO. In addition, glass the tan 8 of the WO glass as a function of temperature... glasses containing WO, in various glass forming nitworks of LifO-B1O0, Na:O-BzO,, and TeO2 were prepared from reagent grade oxides at 800 C - 9SO C in

  16. Fourth intercomparison of personal dosemeters used in US Department of Energy accelerator facilities

    CERN Document Server

    Stewart, R D; Otto, T; Loesch, R M

    2000-01-01

    Personal neutron dosemeters from seven US Department of Energy (DOE) laboratories were mailed to the European Laboratory for Particle Physics (CERN) and irradiated using the well-characterised CERN reference radiation facility (CERF). Neutron dose equivalents determined using the DOE personal dosemeters have been compared to the reference dose equivalent as determined using a tissue-equivalent proportional counter (TEPC). In the 0.5 to 5 mSv dose equivalent range, the comparison of results suggests that the neutron personal dosemeters in use at DOE facilities are capable of estimating dose equivalents for high energy neutrons to within a factor of at least 2 or 3. If a field-specific calibration factor is used to correct the dose equivalent responses, the agreement with the reference dose equivalent for these dosemeters can be improved to better than about 25 to 65at is decoupled from the core in /sup 183,185/Au, becomes the 3/2[532] state (h9/2 parentage) strongly coupled in the doubly-odd /sup 184/Au nucleu...

  17. Field calibration of a TLD albedo dosemeter in the high-energy neutron field of CERF

    International Nuclear Information System (INIS)

    Haninger, T.; Kleinau, P.; Haninger, S.

    2017-01-01

    The new albedo dosemeter-type AWST-TL-GD 04 has been calibrated in the CERF neutron field (CERN-EU high-energy Reference Field). This type of albedo dosemeter is based on thermoluminescent detectors (TLDs) and used by the individual monitoring service of the Helmholtz Zentrum Muenchen (AWST) since 2015 for monitoring persons, who are exposed occupationally against photon and neutron radiation. The motivation for this experiment was to gain a field specific neutron correction factor N n for workplaces at high-energy particle accelerators. N n is a dimensionless factor relative to a basic detector calibration with 137 Cs and is used to calculate the personal neutron dose in terms of H p (10) from the neutron albedo signal. The results show that the sensitivity of the albedo dosemeter for this specific neutron field is not significantly lower as for fast neutrons of a radionuclide source like 252 Cf. The neutron correction factor varies between 0.73 and 1.16 with a midrange value of 0.94. The albedo dosemeter is therefore appropriate to monitor persons, which are exposed at high-energy particle accelerators. (authors)

  18. Dose profile measurement in computerized axial tomography equipment using thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Azorin V, J.C.; Falcony, C.; Azorin N, J.

    2000-01-01

    In this work are presented the results about measuring the radiation dose profile in two equipment of computerized axial tomography (Tac). Thermoluminescent dosemeters (Dtl) of LiF, Mg, Cu, P + Ptfe in form of disks were used which were developed and made in Mexico. The results showed that Dtl are appropriated for these type of studies. (Author)

  19. The development of a personal dosemeter for use by aircraft crew

    International Nuclear Information System (INIS)

    Stokes, R.P.; Talbot, L.

    2000-01-01

    This paper describes preliminary work to develop a cosmic-radiation dosemeter for use by military aircraft crew. The dosemeter is based on a combination of CR-39 etched-track detectors and TLD-700 thermoluminescent detectors. It is intended that the CR-39 be used to assess the neutron dose, while the TLD-700 is used to assess the photon and charged particle dose. The sensitivity of CR-39 to the neutron component of cosmic radiation was estimated by irradiating samples of the plastic at the CERN-CEC High Energy Reference Field Facility. This facility produced a radiation field with a neutron spectrum resembling that of the neutron component of cosmic radiation a typical airflight altitudes. The response of the CR-39 was linear over the range of doses studied (0.2-6.0 mSv) and there was no significant fading in the six-month period after irradiation. The TLD-700 component of the dosemeter was calibrated using 137 Cs gamma rays. The response of the TLD-700 was linear over the range of doses studied (0-1.1 mSv) with no significant fade in the six-month period after irradiation. It was concluded that a combination of CR-39 and TLD-700 detectors would provide an effective cosmic-radiation dosemeter for use by military aircraft crew. (author)

  20. Effect of some parameters in the response of the Perspex 3042, Lot L amber dosemeters

    International Nuclear Information System (INIS)

    Prieto M, E.F.; Barrera G, G.

    2004-01-01

    The answer of the dosimetric systems is affected by several factors, for what should know as these factors they influence in each one of the different dosimetric systems and by this way to minimize its effect in the value of the absorbed dose and to obtain exact dose values. One of the dosimetric systems more used in the high dose dosimetry like routine dosemeter for the control of the irradiation process are the Perspex dosemeters, for their speed in the obtaining the information, their easy manipulation and the precision that they present. To this dosemeters group they belong the same as the Red and Clear the Amber, which are adequate for the measurement of the radiation dose in the range of high doses. The objective of the present work is to obtain the calibration curves of the dosemeters Amber Perspex 3042, Lot L under our work conditions, like they are the irradiation temperatures and of storage and to know the influence of the rate dose in the value of the absorbed dose for different measurement wavelengths, as well as, the relationship among the one post-irradiation time and the specific absorbance value induced in function of the absorbed dose. (Author)

  1. Calibration of personal dosemeters for extremities of fields of radiation gamma

    International Nuclear Information System (INIS)

    Papadopulos, S.; Gregori, S.; Moreno, B.; Guillen, J.

    1998-01-01

    In this work the conversion factors are presented obtained experimentally of kerma in free air in equivalent dose H(d,O o ) in finger and in arm for fields of radiation gamma of normal incidence dosemeters of extremities was irradiated, based on detecting TL of LIF 7 (TLD-700, Harshaw), placed on the surface of the finger phantom and arm

  2. A measurement of the response to fast neutrons of several materials dosemeters

    International Nuclear Information System (INIS)

    Jones, L.T.; Kitching, S.J.; Lewis, T.A.; Playle, T.S.

    1986-07-01

    The response to fast neutrons was measured for three types of materials testing dosemeters: fast neutron dosimetry silicon diodes; beryllia, alumina and calcium fluoride TLDs; graphite walled ionisation chambers. The calibrations were made using a 3MW positive ion accelerator. The arrangement of the target, beam monitor and devices is described, and the measured fast neutron sensitivities are presented. (UK)

  3. Determination of the parameters of traps in thermoluminescent dosemeters of ZrO2: Eu + Ptfe

    International Nuclear Information System (INIS)

    Nieto H, B.; Azorin N, J.; Rivera M, T.

    2002-01-01

    In this work the manufacture of dosemeters in pellets form of ZrO 2 : Eu + Ptfe is described; which after were exposed to UV radiation (260 nm) were generated the corresponding thermoluminescent curves and in the basis to the properties of symmetry of the curves it was determined the kinetic order using the Chen and the Balarin criteria. (Author)

  4. Development of an improved dosemeter for assessments of risk to the eye

    International Nuclear Information System (INIS)

    Eakins, J.S.; Gilvin, P.J.; Hager, L.G.; Tanner, R.J.

    2014-01-01

    To develop an improved dosemeter to assess photon and beta exposures of the eye lens, and in response to issues surrounding the preferred values of H lens to be used for guiding operational radiation protection, a programme of re-optimization of the current PHE thermoluminescence dosemeter has been performed. In particular, refinements of the filter located in front of the sensitive 7 LiF:Mg,Cu,P element have been considered, so that the dose response characteristics of the device provide a better and more conservative estimate of risk. The investigation was performed using the Monte Carlo modelling software MCNP5, to produce a final design that featured a filter containing a 9.5 mm diameter polypropylene hemisphere truncated to a maximum thickness of 3.0 mm. The responses of this design in photon and electron fields are presented here, contrasted against those of the existing PHE eye dosemeter, with respect to the operational quantity H p (3,E,θ) and both current and suggested values for the absorbed dose per fluence risk profile for the lens of the eye. - Highlights: • A programme of re-optimization of the current PHE eye dosemeter has been performed. • A design featuring a truncated hemispherical filter was found to be optimal. • The shape of the filter better resembles the rotational profile of the eye. • Response characteristics depend on the calibration conditions taken to provide the best risk estimate

  5. Thermoluminescent dosemeters (TLD) exposed to high fluxes of gamma radiation, thermal neutrons and protons

    International Nuclear Information System (INIS)

    Gambarini, G.; Martini, M.; Meinardi, F.; Raffaglio, C.; Salvadori, P.; Scacco, A.; Sichirollo, A.E.

    1996-01-01

    Thermoluminescent dosemeters (TLD), widely experimented and utilized in personal dosimetry, have some advantageous characteristics which induce one to employ them also in radiotherapy. The new radiotherapy techniques are aimed at selectively depositing a high dose in cancerous tissues. This goal is reached by utilising both conventional and other more recently proposed radiation, such as thermal neutrons and heavy charged particles. In these inhomogeneous radiation fields a reliable mapping of the spatial distribution of absorbed dose is desirable, and the utilized dosemeters have to give such a possibility without notably perturbing the radiation field with the materials of the dosemeters themselves. TLDs, for their small dimension and their tissue equivalence for most radiation, give good support in the mapping of radiation fields. After exposure to the high fluxes of therapeutic beams, some commercial TL dosemeters have shown a loss of reliability. An investigation has therefore be performed, both on commercial and on laboratory made phosphors, in order to investigate their behaviour in such radiation fields. In particular the thermal neutron and gamma ray mixed field of the thermal column of a nuclear reactor, of interest for Boron Neutron Capture Therapy (B.N.C.T.) and a proton beam, of interest for proton therapy, were considered. Here some results obtained with new TL phosphors exposed in such radiation fields are presented, after a short description of some radiation damage effect on commercial LiF TLDs exposed in the (n th ,γ) field of the thermal column of a reactor. (author)

  6. Calibration of a special neutron dosemeter based on solid-state track detectors and fission radiators in various neutron fields

    International Nuclear Information System (INIS)

    Doerschel, B.; Krusche, M.; Schuricht, V.

    1980-01-01

    The calibration of a personnel neutron dosemeter in different neutron fields is described. The badge-like dosemeter contains 5 detectors: polycarbonate foil (10 μm, Makrofol KG), 232 Th, natural uranium, natural uranium with boron, and natural uranium with cadmium. Detector sensitivity and calibration factors have been calculated and measured in radiation fields of 252 Cf fission neutrons, WWR-S reactor neutrons with and without Cd and Fe shielding, 3-MeV (d,t) generator neutrons, and 238 PuBe neutrons. Measurement range and achievable accuracy are discussed from the point of view of applying the dosemeter in routine and emergency uses

  7. Glass consistency and glass performance

    International Nuclear Information System (INIS)

    Plodinec, M.J.; Ramsey, W.G.

    1994-01-01

    Glass produced by the Defense Waste Processing Facility (DWPF) will have to consistently be more durable than a benchmark glass (evaluated using a short-term leach test), with high confidence. The DWPF has developed a Glass Product Control Program to comply with this specification. However, it is not clear what relevance product consistency has on long-term glass performance. In this report, the authors show that DWPF glass, produced in compliance with this specification, can be expected to effectively limit the release of soluble radionuclides to natural environments. However, the release of insoluble radionuclides to the environment will be limited by their solubility, and not glass durability

  8. Development of CaSO4:Dy based ring dosemeter for extremity monitoring of radiation workers in India

    International Nuclear Information System (INIS)

    Srivastava, Kshama; Meenal, P.; Bhagat, R.V.; Singh, R.; Kolambe, D.H.; Chougaonkar, M.P.; Sapra, B.K.

    2014-01-01

    Extremity dosemeters are required to be worn in cases where the dose to extremities is expected to be significantly greater than the dose to the whole body. In India, CaSO 4 :Dy based three element personnel monitoring TLD badge worn at chest and wrist level are used for whole body and extremity monitoring, respectively. Presently no official/legal finger dosemeter is available for extremity monitoring for radiation workers in the country. To cater to the long standing requirement of finger dosimeter, a new compact three-element Extremity Ring Badge Dosemeter (ERBD) has been developed for measurement of the equivalent doses received by the extremities of radiation workers in terms of operational quantity Hp(0.07). It was aimed to meet the performance requirement of IEC/ISO standards. This paper gives the design detail and result of experimental studies of ERB dosemeter

  9. Energy dependence of ulrathin LiF-dosemeters for high energy electrons and high energy X-radiation

    International Nuclear Information System (INIS)

    Kupfer, T.

    1977-02-01

    The energy dependence of ultrathin LiF-dosemeters for high energy electrons (5-40 MeV) and high energy X-radiation (6 MV, 42 MV) is experimentally determined. The experimental values are compared to values calculted earlier by other authors. The influence of the thickness of the dosemeters have been considered by comparison of experimental values for 0.03 mm thick dosemeters and theoretical values for 0.13 mm and 0.38 mm thick ones. Also different commersially available dosemeters have been compared by experiments. It is difficult to draw any other conclutions about the energy dependence than that the variation of the relative responce is within +- 3 percent (2S). However the results seems to be sulficient for clinical applications

  10. Performance of a PADC personal neutron dosemeter at simulated and real workplace fields of the nuclear industry

    International Nuclear Information System (INIS)

    Fiechtner, A.; Boschung, M.; Wernli, C.

    2007-01-01

    In the framework of the EVIDOS (Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields) project, funded by the EC, measurements with PADC personal neutron dosemeters were carried out at several workplace fields of the nuclear industry and at simulated workplace fields. The measured personal neutron dose equivalents of the PADC personal neutron dosemeter are compared with values that were assessed within the EVIDOS project by other partners. The detection limits for different spectra types are given. In cases were the neutron dose was too low to be measured by the PADC personal neutron dosemeter, the response is estimated by convoluting the responses to monoenergetic neutrons with the dose energy distribution measured within EVIDOS. The advantages and limitations of the PADC personal neutron dosemeter are discussed. (authors)

  11. Colloidal glasses

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Colloidal glasses. Glassy state is attained when system fails to reach equilibrium due to crowding of constituent particles. In molecular glasses, glassy state is reached by rapidly lowering the temperature. In colloidal glasses, glassy state is reached by increasing the ...

  12. Systematic errors in the readings of track etch neutron dosemeters caused by the energy dependence of response

    International Nuclear Information System (INIS)

    Tanner, R.J.; Thomas, D.J.; Bartlett, D.T.; Horwood, N.

    1999-01-01

    A study has been performed to assess the extent to which variations in the energy dependence of response of neutron personal dosemeters can cause systematic errors in readings obtained in workplace fields. This involved a detailed determination of the response functions of personal dosemeters used in the UK. These response functions were folded with workplace spectra to ascertain the under- or over-response in workplace fields

  13. Systematic errors in the readings of track etch neutron dosemeters caused by the energy dependence of response

    CERN Document Server

    Tanner, R J; Bartlett, D T; Horwood, N

    1999-01-01

    A study has been performed to assess the extent to which variations in the energy dependence of response of neutron personal dosemeters can cause systematic errors in readings obtained in workplace fields. This involved a detailed determination of the response functions of personal dosemeters used in the UK. These response functions were folded with workplace spectra to ascertain the under- or over-response in workplace fields.

  14. Use of a robotic manipulator in the simulation of the automation of a calibration process of dosemeters

    International Nuclear Information System (INIS)

    Benitez R, J.S.; Najera H, M.C.

    2002-01-01

    The development of a system based in a manipulative robot which simulates the operative sequence in a calibration process of dosemeters is presented. In this process it is performed the monitoring of the dosemeter positions and the calibrator by mean of an arm of articulated robot which develops the movement sequences and the taking a decision based on the information coming from the external sensors. (Author)

  15. Comparative measurements of external radiation exposure using mobile phones, dental ceramic, household salt and conventional personal dosemeters

    International Nuclear Information System (INIS)

    Ekendahl, Daniela; Bulánek, Boris; Judas, Libor

    2015-01-01

    Because retrospective dosimetry utilises commonly occurring materials and objects, it is particularly useful in cases of large-scale radiation accidents or malevolent acts with radioactive materials where casualties are inflicted on the general public and first emergency responders. The aim of this study was to investigate whether retrospective dosemeters can provide dose estimates with comparable accuracy like conventional personal dosemeters. Using an external source of radiation 137 Cs and an anthropomorphic phantom, we simulated serious irradiation of a human body in anterior-posterior and rotational geometries. Retrospective luminescence dosimetry objects, such as mobile phones, dental ceramic and household salt, and conventional personal dosemeters (thermoluminescent and electronic) were fixed to the anthropomorphic phantom. The doses obtained were compared with specific reference values. In most cases, relative deviations between the measured doses and the reference values did not exceed 20%. As the retrospective and conventional dosemeters show no significant differences in laboratory conditions, the retrospective luminescence dosimetry objects represent a very promising tool if handled properly. - Highlights: • A serious external exposure of human body was simulated. • Doses were measured using both retrospective and conventional dosemeters. • Utilised retrospective dosimetry materials were alumina resistors from mobile phones, household salt and dental ceramic. • Doses obtained were compared with reference values. • Both retrospective and conventional dosemeters gave similar results

  16. Silicate glasses

    International Nuclear Information System (INIS)

    Lutze, W.

    1988-01-01

    Vitrification of liquid high-level radioactive wastes has received the greatest attention, world-wide, compared to any other HLW solidification process. The waste form is a borosilicate-based glass. The production of phosphate-based glass has been abandoned in the western world. Only in the Soviet Union are phosphate-based glasses still being developed. Vitrification techniques, equipment and processes and their remote operation have been developed and studied for almost thirty years and have reached a high degree of technical maturity. Industrial demonstration of the vitrification process has been in progress since 1978. This chapter is a survey of world-wide research and development efforts in nuclear waste glasses and its production technology. The principal glasses considered are silicate glasses which contain boron, i.e., borosilicate glasses

  17. Characterization of a two-component thermoluminescent albedo dosemeter according to ISO 21909

    Energy Technology Data Exchange (ETDEWEB)

    Martins, M.M., E-mail: marcelo@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN), Av. Salvador Allende s/n, CEP 22780-160, Rio de Janeiro, RJ (Brazil); Mauricio, C.L.P., E-mail: claudia@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN), Av. Salvador Allende s/n, CEP 22780-160, Rio de Janeiro, RJ (Brazil); Pereira, W.W., E-mail: walsan@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN), Av. Salvador Allende s/n, CEP 22780-160, Rio de Janeiro, RJ (Brazil); Silva, A.X. da, E-mail: ademir@con.ufrj.b [Coordenacao dos Programas de Pos-Graduacao em Engenharia, COPPE/PEN Caixa Postal 68509, CEP 21941-972, Rio de Janeiro, RJ (Brazil)

    2011-05-15

    A two-component thermoluminescent albedo neutron monitoring system was developed at Instituto de Radioprotecao e Dosimetria, Brazil. As there is no Brazilian regulation for neutron individual monitoring service, the system was tested according to the ISO 21909 standard. This standard provides performance and test requirements for determining the acceptability of personal neutron dosemeters to be used for the measurement of personal dose equivalent, H{sub p}(10), in neutron fields with energies ranging from thermal to 20 MeV. Up to 40 dosemeters were used in order to accomplish satisfactorily the requirements of some tests. Despite operational difficulties, this albedo system passed all ISO 21909 performance requirements. The results and problems throughout this characterization are discussed in this paper.

  18. Dissolution behaviour of 238U, 234U and 230Th deposited on filters from personal dosemeters.

    Science.gov (United States)

    Becková, Vera; Malátová, Irena

    2008-01-01

    Kinetics of dissolution of (238)U, (234)U and (230)Th dust deposited on filters from personal alpha dosemeters was studied by means of a 26-d in vitro dissolution test with a serum ultrafiltrate simulant. Dosemeters had been used by miners at the uranium mine 'Dolní Rozínka' at Rozná, Czech Republic. The sampling flow-rate as declared by the producer is 4 l h(-1) and the sampling period is typically 1 month. Studied filters contained 125 +/- 6 mBq (238)U in equilibrium with (234)U and (230)Th; no (232)Th series nuclides were found. Half-time of rapid dissolution of 1.4 d for (238)U and (234)U and slow dissolution half-times of 173 and 116 d were found for (238)U and (234)U, respectively. No detectable dissolution of (230)Th was found.

  19. Dissolution behaviour of 238U, 234U and 230Th deposited on filters from personal dosemeters

    International Nuclear Information System (INIS)

    Beckova, V.; Malatova, I.

    2008-01-01

    Kinetics of dissolution of 238 U, 234 U and 230 Th dust deposited on filters from personal alpha dosemeters was studied by means of a 26-d in vitro dissolution test with a serum ultra-filtrate simulant. Dosemeters had been used by miners at the uranium mine 'Dolni Rozinka' at Rozna, Czech Republic. The sampling flow-rate as declared by the producer is 4 l h -1 and the sampling period is typically 1 month. Studied filters contained 125 ± 6 mBq 238 U in equilibrium with 234 U and 230 Th; no 232 Th series nuclides were found. Half-time of rapid dissolution of 1.4 d for 238 U and 234 U and slow dissolution half-times of 173 and 116 d were found for 238 U and 234 U, respectively. No detectable dissolution of 230 Th was found. (authors)

  20. Measuring radiation exposure during percutaneous drainages: can shoulder dosemeters be used to estimate finger doses?

    International Nuclear Information System (INIS)

    Vehmas, Tapio; Tikkanen, Heikki

    1992-01-01

    To assess the need for extra finger dosemeters, radiologists' and assistants' radiation exposure at both shoulders and at the third fingers of both hands were recorded using thermoluminescent dosemeters during 27 interventional drainage procedures. Under couch screening was used. Mean dose rates were calculated by dividing dose by screening time. The radiologists' bilateral finger dose rates did not correlate with each other; nor did dose rates between the left shoulder and the right hand. The radiologists' dose rates at both shoulders, correlated with each other, as did shoulder dose rates with dose rates at the ispilateral hand. The right shoulder dose rates correlated with the left hand dose rates. The assistants' dose rates at places of measurement showed significant correlations with each other. (Author)

  1. Contribution to the development study of a personal fast neutron dosemeter using nuclear emulsion

    International Nuclear Information System (INIS)

    Ott, C.

    1985-02-01

    This work deals with the response of a personal neutron dosemeter using nuclear emulsion. The main characteristics of the detector are studied with the help of a computer programme simulating the conditions of the formation of recoil protons tracks recorded by nuclear emulsions. The lecture limits of nuclear emulsions with light microscope and the validity of our computer code are checked by comparing our theoretical values with experimental results [fr

  2. Exposure levels to radiation in a nuclear medicine laboratory: measurements with thermoluminescence dosemeters

    International Nuclear Information System (INIS)

    Ruiz J, A.

    2000-01-01

    Since 1996 in the Nuclear medicine Department and another routine and research departments of the National Institute of Medical and Nutrition Sciences (INCMNSZ) are working at least with 12 radioactive sources opened and sealed. However, it was unknown if with the Tl personal dosemeters with lithium fluoride crystals (LiF), could be possible to receive information about the equivalent dose for each radionuclide or if there was some radionuclide that by being low energy emissor or beta energy emissor, it did not represent an ionization power sufficient to excite the crystals of the thermoluminescent dosemeters (DTL). In this work the obtained results with control dosemeters of diverse source opened or sealed are shown, which were put at 1 cm of the LiF crystals during a time exposure 18 hours. Therefore the objective of this work is to verify which sources excite or not to DTL crystals and taking the pertinent safety measures for each radionuclide. The conclusion is that the majority of dosemeters were excited by beta or gamma radiation of the radionuclides and that LiF crystals are able to receive equivalent doses until 1200 mSv, being this a guarantee for the staff, that in an any moment could be exposed to high dose in his working day. Also it was corroborated that the radionuclides more energizer are: iodine-131, iodine-125 and sodium-22 while the phosphorus-32 must be managed with careful, since the exposure to hands can result significant, just like the technetium-99m ( 99m Tc). (Author)

  3. Possibility of the use of PVC plastics as a ray dosemeter

    International Nuclear Information System (INIS)

    Amri Ayat; Sutrisno Puspodikoro.

    1978-01-01

    The use of plastics as a radiation dosemeter for measurement of γ-rays is very attractive to be studied. In the work presented here commercial PVC film with the trade-mark ''Takiron'' is used for Co-60 radiation dosimetry. According to the experiments the useful dose range extends over 0.15-1.2 Mrads. Fading of the coloration with time after radiation exposure can be stabilised by heat treatment (60 deg C for 30 minutes). (author)

  4. Determination of the dose index in computerized tomography using thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Azorin, J.C.; Calderon, A.; Azorin, J.

    2004-01-01

    In this work the obtained results of the determination of the dose index are presented in thorax studies in computed tomography and helical tomography carried out in Mexico using thermoluminescent dosemeters of LiF: Mg,Cu,P + Ptfe developed and manufactured in our country. The results showed that under similar conditions of irradiation and operation (pitch = 1), significant differences don't exist among the doses absorbed measures in the phantom due to the two types of used tomographs. (Author)

  5. Dose estimation by simultaneous measurement of the radon/thoron concentration and the equilibrium factors in air using a passive dosemeter

    International Nuclear Information System (INIS)

    Urban, M.

    1984-03-01

    Responsible for an increased radiation exposure is the inhalation of radon and its short lived daughters. A time integrating passive dosemeter was developed to determine the concentrations of the radon isotopes as well as their equilibrium factors. The α energy spectrum inside a dosemeter is measured by means of a nuclear track detector. The concentrations in air and the equilibrium factors are calculated by using a new mathematical dosemeter model. A small pilot study in houses was done to test the dosemeter. (orig.) [de

  6. Operational trials of single- and multi-element CR-39 dosemeters for the DIDO and PLUTO reactors at the Harwell Laboratory

    International Nuclear Information System (INIS)

    Gallacher, G.G.; Perks, C.A.

    1993-01-01

    Single- and multi-element CR-39 dosemeters, developed at the Harwell Laboratory, and a commercially available multi-element CR-39 dosemeter (obtained from Track Analysis Systems Ltd), were evaluated for their potential as neutron dosemeters for personnel working at Harwell Laboratory's research reactors. Owing to the angular dependence of the CR-39 (processed using electrochemical etching), the single-element dosemeter was found to be impractical. Consequently, a multi-element dosemeter was developed, which consisted of a cube of side 36 mm with CR-39 elements (also processed using electrochemical etching) attached to each of the sides. Although this dosemeter was technically suitable for this type of dosimetry, it was considered to be unacceptably bulky in personnel trials. The commercially available CR-39 dosemeter tested was much smaller (the CR-39 was only chemically etched) and this was considered to be acceptable as a personnel dosemeter. In addition, trials with personnel working at active handling glove boxes indicated that single-element dosemeters might be adequate, but further work would be needed to verify this. (author)

  7. Performance testing of personal dosemeters from eleven dosimetry services in Sweden

    International Nuclear Information System (INIS)

    Lund, E.; Kylloenen, J.-E.; Grindborg, J.-E.; Lindborg, L.

    2001-01-01

    The Swedish regulation, SSI FS 98:5, requires that radiological workers of category A use dosemeters from an approved personal dosimetry service. The 11 services operating in Sweden at the moment use five different types of dosemeter. All have been tested for their ability to determine H p (10) and some of them to determine H p (0.07) according to the European Commission report Radiation Protection 73, EUR 14852, of 1994. The five unique systems have been tested regarding the angular and energy dependence of the response of the dosemeters. The test points for the determination of H p (10) are all, except one, within the trumpet curve and for the unique systems it is shown that the uncertainty related to angular response at three different energies is within the required ±40% except for the lowest X ray quality 40 kV. The energy dependence dominates over the directional dependence and the choice of radiation quality for calibration is of great importance for the system performance. (author)

  8. Performance tests of a CaSO4:Dy based thermoluminescence personal dosemeter

    International Nuclear Information System (INIS)

    Azorin, J.; Gutierrez, A.; Niewiadomski, T.

    1986-01-01

    In order to replace LiF commercial thermoluminescence dosemeters (TLDs) now used in personnel monitoring, we developed a TLD personnel monitoring badge based on pellets of CaSO 4 :Dy bound in pure KBr placed in plastic holders provided with 0.8 mm Pb filters to compensate for the energy dependence of CaSO 4 :Dy. Performance tests, based on the proposals of international standards for TLDs intended to be used as general deep tissue personal dosemeters, were done by developing the detailed test methods both for the tests required by the International Atomic Energy Agency (fading, linearity, effect of fluorescent light and sunlight and stability under standard climatic conditions) and to meet the requirements of the International Electrotechnical Commission (batch homogeneity, detection threshold, stability of zero point repeatibility and residual). Initial tests showed a high residual and an increase of inhomogeneity. However, these drawbacks were overcome by changing the annealing procedure and the readout conditions. Using these new conditions TLDs met all the requirements for personal dosemeters. (author)

  9. Evaluation of two personal dosemeters in polyenergetic mono- and multi-directional neutron fields

    International Nuclear Information System (INIS)

    Nunes, J. C.; Surette, R. A.

    2005-01-01

    The neutron dose-equivalent response of two commercially available electronic personal neutron dosemeters was studied in several laboratory-produced broad-spectrum neutron fields. Fluence-weighted mean energies ranged from 200 keV to 4 MeV; personal dose-equivalent rates ranged from 75 to 10 mSv h -1 ; and angles of incidence were multidirectional, 0 deg., 30 deg. and 60 deg.. Three of these fields have been shown previously to resemble ones found in CANDU (Canadian Deuterium Uranium is a registered trademark of the Atomic Energy of Canada Limited) power plant workplaces. Both dosemeters were found to perform reasonably well across the range of energy spectra and angles of incidence. One type of dosemeter displayed values of the personal dose equivalent that were, at worst, within a factor of ∼2 of the reference values and, at best, within a few per cent of the reference values. The other type displayed values of the personal dose equivalent that were consistently within unity and 20% of the reference values. Although the radiological performance of one was found to be more accurate, this device was also found to be the less rugged of the two. Some of the data acquired in this work were compared with results previously published by others. There was consistency between these sets of data. (authors)

  10. A portable versatile x-and γ-ray dosemeter with digital display for medical use

    International Nuclear Information System (INIS)

    Sankaran, A.; Gangadharan, P.

    1980-01-01

    A multipurpose dosemeter based on analogue-to-digital (A-D) conversion has been developed using solid state devices, micropower integrated circuits and displays. The A-D converter combines the features of a MOSFET electrometer, a voltage-to-frequency converter, the automatic Townsend balance, LED(LCD) display for exposure, analogue output and has a voltage-measuring accuracy of +-O.1% FS+-1 digit. The dosemeter which is designed to measure a wide range of X- and γ-ray exposure rates (1 mRh -1 to 1000 R min -1 ) and exposures (1 mR to 1000 R) with a variety of air-equivalent ionisation chambers, is compact, rugged and battery or AC mains powered. It is designed to provide trouble-free performance, easy operation and maintenance and to be independent of climatic conditions. Combining the features of a survey meter, dosemeter and a radioisotope calibrator, it can be fabricated using the facilities locally available in hospitals or universities. (author)

  11. Recycle Glass in Foam Glass Production

    DEFF Research Database (Denmark)

    Petersen, Rasmus Rosenlund; König, Jakob; Yue, Yuanzheng

    The foam glass industry turn recycle glass into heat insulating building materials. The foaming process is relative insensitive to impurities in the recycle glass. It is therefore considered to play an important role in future glass recycling. We show and discuss trends of use of recycled glasses...... in foam glass industry and the supply sources and capacity of recycle glass....

  12. Thermoluminescent response of dosemeters TLD-100 exposed to distinct baker protocols, irradiation and reading

    International Nuclear Information System (INIS)

    Estrada E, D.

    2002-01-01

    The interest that motivated the realization of this work is the opposing discrepancy among the values of the efficiency thermoluminescent of heavy charged particles (PCP) regarding gamma radiation (η PCP , γ) reported in different works and gathered recently for Horowitz (Ho 01). The measures of relative thermoluminescent efficiency have importance in relation to the dosimetry associated to medical therapy with heavy charged particle. The measurement of η PCP , γ depends of multiple experimental factors. To understand this dependence it was quantified the effect of using different procedures experimental in the estimate of the relative thermoluminescent efficiency of dosemeters TLD-100 (LiF: Ti; Mg) for protons of 3 MeV regarding gamma rays of 60 Co (η PCP , γ), varying the lot, the presentation, the one baked and the team reader. When was used the same global procedure values they were obtained for (η PCP , γ) inside the interval [0.30, 0.58] for the peak 5 and [0.35, 0.76] for the total thermoluminescent signal (Tl). At the use different equipment, baked and lot are obtained maximum differences of 30%, 12% and 6% respectively in the values of (η PCP , γ) for the peak 5, and 25%, 28% and 7% for the total Tl signal. The changes more significant of 36% and 44% for peak 5 and total signal respectively are obtained when changing the presentation of the dosemeter. As a complementary investigation it was studied the distribution of the Tl signal of each peak in the deconvolution of the curve of brightness with regard to the total signal in exposed dosemeters to high fluence of protons (1x10 10 p/cm 2 ) varying the experimental protocol. It was found that the distribution of the Tl signal has a difference of the order of 5% when changing the used reading team. It was observed that the contribution of the peak 5 regarding the total signal are preserved when changing baked and that it results to be 8% greater for the presentation in dosemeters of 1 x 1 x 1 mm 3

  13. Mensuration of equivalent dose with personal dosemeters and instruments of radiological protection in the new operative quantities ICRU, for external fields of beta radiation. Part II. I study of the angular response of personal dosemeters TLD-100 in secondary patron fields of beta radiation ({sup 90}Sr / {sup 90}Y); Medicion de dosis equivalente con dosimetros personales e instrumentos de proteccion radiologica en las nuevas magnitudes operativas ICRU, para campos de radiacion beta externos. Parte II. Estudio de la respuesta angular de dosimetros personales TLD-100 en campos patrones secundarios de radiacion beta ({sup 90}Sr/{sup 90}Y)

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J.T. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1994-01-15

    The objective of this work is to carry out one of the possible ones test type for personal dosemeters TLD, under the recomendations of the ICRU 39, ICRU 43 and the draft of the norm ISO 6980,(1992), with the purpose of verifying the capacity of these detectors to carry out the operative unit: H' (0.07;{alpha}). Since H' (O. 07;{alpha}) this defined one in an expanded field, one of these tests type consist on determining the angular response of these detectors. 20 personal dosemeters TLD-100 was used, (card marks: Harshaw, Model: G-1, with two glasses of TLD-100 absorbed in teflon; the portadosemeters has two windows, a free one and another with a filter of Pb of 171.0 mg cm{sup -2}); these dosemeters they were previously selected, [to see, {sup S}tudy of the Homogeneity of the response of Personal Dosemeters (Cards G-l, TLD-100) in Radiation of Countrysides of {sup 60}Co{sup ,} J.T. Alvarez R. Technician Report GSR/IT/0001/94].The irradiations to effectued in secondary countryside of radiation beta of {sup 90}Sr/{sup 90}Y. The study was undertaken by means of an experimental design of blocks random that contemplate the following variables: intensity of the radiation source, (1850 MBq and 74 MBq); position of irradiation, (four positions); incidence of angle of the radiation (0, 15, 30, 45, 60 and 75 grades) and the absorbed dose in air, (0.005, 0.010, 0.020, 0.050 and 0.100 Gy). Then null hypothesis it was to suppose that there was not difference among the stockings of each treatment, to used the statistical of Duncan to carry out tests of stockings at a level of significance of 5%.These tests of stockings throw the following results in those variables of the experimental design: The irradiations carried out so much with the source pattern secondary of {sup 90}Sr/{sup 90}Y of 1850 MBq and of 74 MBq, they are equivalent reason why they can be used indistinctly. The responses of each one of the glasses of the card are strongly anisotropic for each glass

  14. Cosmos & Glass

    DEFF Research Database (Denmark)

    Beim, Anne

    1996-01-01

    The article unfolds the architectural visions of glass by Bruno Taut. It refers to inspirations by Paul Sheerbart and litterature and the Crystal Chain, also it analyses the tectonic univers that can be found in the glass pavillion for the Werkbund exposition in Cologne....

  15. Glass Glimpsed

    DEFF Research Database (Denmark)

    Lock, Charles

    2015-01-01

    Glass in poetry as it reflects the viewer and as its power of reflection are both reduced and enhanced by technology.......Glass in poetry as it reflects the viewer and as its power of reflection are both reduced and enhanced by technology....

  16. Spin glasses

    CERN Document Server

    Bovier, Anton

    2007-01-01

    Spin glass theory is going through a stunning period of progress while finding exciting new applications in areas beyond theoretical physics, in particular in combinatorics and computer science. This collection of state-of-the-art review papers written by leading experts in the field covers the topic from a wide variety of angles. The topics covered are mean field spin glasses, including a pedagogical account of Talagrand's proof of the Parisi solution, short range spin glasses, emphasizing the open problem of the relevance of the mean-field theory for lattice models, and the dynamics of spin glasses, in particular the problem of ageing in mean field models. The book will serve as a concise introduction to the state of the art of spin glass theory, usefull to both graduate students and young researchers, as well as to anyone curious to know what is going on in this exciting area of mathematical physics.

  17. Evaluations of absorbed dose ratio factor of Al2O3 dosemeter in radiotherapy photon beams using cavity theory

    International Nuclear Information System (INIS)

    Zhu, J.; Chen, S.; Chen, L.; Liu, X.

    2012-01-01

    The aim of the work was to evaluate the absorbed dose ratio factor f md of an Al 2 O 3 dosemeter to water in photon radiotherapy beams using cavity theory. Burlin theory was used for calculating of this ratio. The effective mass attenuation coefficient β was obtained by comparing Monte Carlo simulations in monoenergetic photon beams. The evaluations of the absorbed dose ratio factor f md were studied for Al 2 O 3 dosemeters of different sizes, which were placed at various depths of the water phantom in different radiation field sizes of Mohan's 6, 10 and 15-MV X-rays. Beyond the build-up region, the variation of f md increases by 0.25 % as the depth increases from 4 to 10 cm. The maximum variation due to different dosemeter sizes is 8.3 %. The difference in the f md due to different radiation field sizes is 1.5 %. The effect of the dosemeter size cannot be neglected. The difference in the f md due to the radiation field sizes of different beams would increase as the dosemeter size increases. (authors)

  18. Individual monitoring and its quality assurance using thermoluminescent CaSO[sub 4]:Dy Teflon tape dosemeters in India

    Energy Technology Data Exchange (ETDEWEB)

    Nagpal, J.S.; Popli, K.L.; Varadharajan, G.; Kher, R.K.; Venkataraman, G. (Bhabha Atomic Research Centre, Bombay (India). Div. of Radiological Protection)

    1994-01-01

    CaSO[sub 4]:Dy Teflon thermoluminscence dosemeters have been fabricated indigenously in continuous tape form. TL response of the tape dosemeters to [beta] and [gamma] radiations has been studied as a function of the dosemeter thickness to arrive at its optimum value. A single 80 mg.cm[sup -2] thick tape dosemeter (51 mm x 17 mm) along with a mica strip replaces the earlier use of three 200 mg.cm[sup -2] thick disc dosemeters for routine individual monitoring. The tape cards have been in field use for two and half years. The performance characteristics of the cards under laboratory and field conditions are discussed. Dose computation algorithms have been developed to give whole-body dose (mGy) and skin dose (mGy)for photons and [beta] radiation respectively from the TL outputs of three dosimetric elements under 1000 mg.cm[sup -2] Cu + Al composite filter, 180 mg.cm[sup -2] Perspex and an open region in a cardholder. Results of the Quality Assurance Programme, covering various TL monitoring stations in India, are also presented. Based on ANSI criteria, only one outlier was observed over the past seven years. (Author).

  19. Validation of a MOSFET dosemeter system for determining the absorbed and effective radiation doses in diagnostic radiology.

    Science.gov (United States)

    Manninen, A-L; Kotiaho, A; Nikkinen, J; Nieminen, M T

    2015-04-01

    This study aimed to validate a MOSFET dosemeter system for determining absorbed and effective doses (EDs) in the dose and energy range used in diagnostic radiology. Energy dependence, dose linearity and repeatability of the dosemeter were examined. The absorbed doses (ADs) were compared at anterior-posterior projection and the EDs were determined at posterior-anterior, anterior-posterior and lateral projections of thoracic imaging using an anthropomorphic phantom. The radiation exposures were made using digital radiography systems. This study revealed that the MOSFET system with high sensitivity bias supply set-up is sufficiently accurate for AD and ED determination. The dosemeter is recommended to be calibrated for energies 80 kVp. The entrance skin dose level should be at least 5 mGy to minimise the deviation of the individual dosemeter dose. For ED determination, dosemeters should be implanted perpendicular to the surface of the phantom to prevent the angular dependence error. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Tl response of LiF: Mg, Cu, P + PTFE (Mexico) and GR200A (China) dosemeters

    International Nuclear Information System (INIS)

    Gonzalez M, P.R.; Azorin N, J.; Furetta, C.

    2003-01-01

    TLD-100 was the commercial dosemeter more known since some decades ago. This dosemeter was considered for many research groups as the reference material for developing new Tl materials for ionizing radiation dosimetry. Actually it seems that TLD-100 is going to be replaced by the Chinese material GR200A, as reference material due that this material in addition to be considered as a tissue equivalent material, is 30 to 35 times more sensitive that TLD- 100. Results of the study of the Tl response of LiF: Mg, Cu, P + Ptfe developed at ININ-Mexico, comparing them with those of GR200A are presented. These results showed that the sensitivity (s = Tl intensity/weight x dose) to gamma radiation of the LiF: Mg, Cu, P + Ptfe dosimeters was 4.34 meanwhile that of the commercial dosemeter was 3.41. Detection threshold of the dosemeters studied was 2.22 and 0.52 μGy respectively Repeatability after 10 cycles Irradiation-reading-annealing was ±1.39% and ±1.86% respectively. Both types of dosemeters presented a linear response as a function of gamma radiation in the range from 0.02 mGy and 100 Gy. (Author)

  1. Effective dose assessment in the maxillofacial region using thermoluminescent (TLD) and metal oxide semiconductor field-effect transistor (MOSFET) dosemeters: a comparative study

    NARCIS (Netherlands)

    Koivisto, J.; Schulze, D.; Wolff, J.E.H.; Rottke, D.

    2014-01-01

    Objectives: The objective of this study was to compare the performance of metal oxide semiconductor field-effect transistor (MOSFET) technology dosemeters with thermoluminescent dosemeters (TLDs) (TLD 100; Thermo Fisher Scientific, Waltham, MA) in the maxillofacial area. Methods: Organ and effective

  2. Photon and fast neutron dosimetry using aluminium oxide thermoluminescence dosemeters in a pool-type research reactor

    International Nuclear Information System (INIS)

    Santos, J.P.; Marques, J.G.; Fernandes, A.C.; Osvay, M.

    2007-01-01

    Al 2 O 3 :Mg,Y thermoluminescence (TL) dosemeters were used to measure photon and fast neutron doses in the mixed radiation field of the Portuguese Research Reactor. The dosemeters were irradiated in core positions under a photon dose rate of the order of 10 4 Gy/h and a fast neutron flux in the range of 10 9 -10 11 n/cm 2 /s. In order to evaluate the ability of the TL dosemeters for mixed field dosimetry at the research reactor, the measurements were compared with results obtained via conventional methods. The agreement between the different methods is better than 13% for the determination of photon doses and within 5% for the determination of neutron fluxes in mixed fields

  3. Characteristics and performance of the Sunna high dose dosemeter using green photoluminescence and UV absorption readout methods

    Energy Technology Data Exchange (ETDEWEB)

    Miller, S.D.; Murphy, M.K.; Tinker, M.R.; Kovacs, A.; McLaughlin, W

    2002-07-01

    Growth in the use of ionising radiation for medical sterilisation and the potential for wide-scale international food irradiation have created the need for robust, mass-producible, inexpensive, and highly accurate radiation dosemeters. The Sunna dosemeter, lithium fluoride injection-moulded in a polyethylene matrix, can be read out using either green photoluminescence or ultraviolet (UV) absorption. The Sunna dosemeter can be mass-produced inexpensively with high precision. Both the photoluminescent and the UV absorption reader are simple and inexpensive. Both methods of analysis display negligible humidity effects, minimal dose rate dependence, acceptable post-irradiation effects, and permit measurements with a precision of nearly 1% 1s. The UV method shows negligible irradiation temperature effects from -30 deg. C to +60 deg. C. The photoluminescence method shows negligible irradiation temperature effects above room temperature for sterilisation dose levels and above. The dosimetry characteristics of these two readout methods are presented along with performance data in commercial sterilisation facilities. (author)

  4. Influence of the PMMA and the ISO slab phantom for calibrating personal dosemeters

    International Nuclear Information System (INIS)

    Ginjaume, M.; Ortega, X.; Barbosa, A.

    2000-01-01

    Wide agreement has been achieved among the main Bodies and Organisations involved in standardisation of radiation protection, related to the operational quantities for personal dosimetry. Since their definition in 1985, several reports have been published to clarify and define the experimental set up to be used for the calibration of dosemeters in terms of the above-mentioned quantities. Among these lines, ICRU 47 has listed five different phantoms that are used for calibration and whose results were accurate, within accepted uncertainties. However, to achieve uniformity in calibration procedures, the 30 cm x 30 cm x 15 cm PMMA slab phantom was recommended. The secondary calibration Laboratory from the Institut de Techniques Energetiques at the Technical University of Catalonia (UPC) agreed with the Spanish Nacional Laboratory to adopt the recommended PMMA phantom but to improve the accuracy of the calibration procedure, by introducing a correction factor for backscatter differences in a PMMA and an ICRU slab phantom. Such corrections were of the order of 8% for the low-energy X-ray qualities. Recently, ISO in ISO 4037-3, has proposed the ISO water slab phantom which consists of a 30 cm x 30 cm x 15 cm water phantom with PMMA walls (front wall 2.5 mm thick). This new phantom could be substituted by the above mentioned PMMA phantom for radiation qualities with mean energy equal or above that of 137 Cs. The aim of this work is to compare the influence of both phantoms when calibrating personal dosemeters with photons. A set of four TL personal dosemeters that are used in the UPC personal dosimetry Service and an electronic personal dosemeter (SIEMENS EPD-2) were calibrated in terms of H p (10) and H p (0.07) using the two proposed phantoms. Calibration factors for ISO X-ray narrow spectra, 137 Cs and 60 Co were experimentally obtained for each phantom and compared. In the TL measurements, differences were found to be within TL statistical uncertainty, provided that a

  5. A filter technique for optimising the photon energy response of a silicon pin diode dosemeter

    International Nuclear Information System (INIS)

    Olsher, R.H.; Eisen, Y.

    1996-01-01

    Unless they are energy compensated, silicon PIN diodes used in electronic pocket dosemeters, have significant over-response below 200 keV. Siemens is using three diodes in parallel with individual filters to produce excellent energy and angular response. An algorithm based on the photon spectrum of a single diode could be used to flatten the energy response. The commercial practice is to use a single diode with a simple filter to flatten the energy response, despite the mediocre low energy photon. The filter technique with an opening has been used for energy compensating GM detectors and proportional counters and a new variation of it has been investigated which compensates the energy response of a silicon PIN diode and maintains an extended low energy response. It uses a composite filter of two or more materials with several openings whose individual area is in the range of 15% to 25% of the diode's active area. One opening is centred over the diode's active area and others are located at the periphery of the active area to preserve a good polar response to ±45 o . Monte Carlo radiation transport methods were used to simulate the coupled electron-photon transport through a Hamamatsu S2506-01 diode and to determine the energy response of the diode for a variety of filters. In current mode, the resultant dosemeter energy response relative to air dose was within -15% and +30% for 0 o incidence over the energy range from 15 keV to 1 MeV. In pulse mode, the resultant dosemeter energy response was within -25% and +50% for 0 o incidence over the energy range from 30 keV to 10 MeV. For ±45 o incidence, the energy response was within -25% and +40% from 40 keV to 10 MeV. Theoretical viability of the filter technique has been shown in this work (Author)

  6. Eye lens monitoring for interventional radiology personnel: dosemeters, calibration and practical aspects of Hp(3) monitoring. A 2015 review

    International Nuclear Information System (INIS)

    Carinou, Eleftheria; Ferrari, Paolo; Bjelac, Olivera Ciraj; Gingaume, Merce; Merce, Marta Sans; O’Connor, Una

    2015-01-01

    A thorough literature review about the current situation on the implementation of eye lens monitoring has been performed in order to provide recommendations regarding dosemeter types, calibration procedures and practical aspects of eye lens monitoring for interventional radiology personnel. Most relevant data and recommendations from about 100 papers have been analysed and classified in the following topics: challenges of today in eye lens monitoring; conversion coefficients, phantoms and calibration procedures for eye lens dose evaluation; correction factors and dosemeters for eye lens dose measurements; dosemeter position and influence of protective devices. The major findings of the review can be summarised as follows: the recommended operational quantity for the eye lens monitoring is H p (3). At present, several dosemeters are available for eye lens monitoring and calibration procedures are being developed. However, in practice, very often, alternative methods are used to assess the dose to the eye lens. A summary of correction factors found in the literature for the assessment of the eye lens dose is provided. These factors can give an estimation of the eye lens dose when alternative methods, such as the use of a whole body dosemeter, are used. A wide range of values is found, thus indicating the large uncertainty associated with these simplified methods. Reduction factors from most common protective devices obtained experimentally and using Monte Carlo calculations are presented. The paper concludes that the use of a dosemeter placed at collar level outside the lead apron can provide a useful first estimate of the eye lens exposure. However, for workplaces with estimated annual equivalent dose to the eye lens close to the dose limit, specific eye lens monitoring should be performed. Finally, training of the involved medical staff on the risks of ionising radiation for the eye lens and on the correct use of protective systems is strongly recommended. (review)

  7. GLASS BOX

    National Research Council Canada - National Science Library

    Curtis, Laura

    2008-01-01

    The goals of this effort were to develop Glass Box capabilities to allow for the capturing of analyst activities and the associated data resources, track and log the results of automated processing...

  8. A review of environmental monitoring using solid state dosemeters, and guidelines for technical procedures

    International Nuclear Information System (INIS)

    Piesch, E.; Burgkhardt, B.

    1983-01-01

    The practical aspects of environmental programmes using thermoluminescence and photoluminescence dosemeter systems are reviewed. The review discusses developments in national and international standards, and discusses the optimisation of the read-out technique, routine calibration procedures and the treatment of random and systematic errors. The paper discusses the problems of measuring man-made dose contributions with low random errors, the estimation of this contribution being based on the interpretation of field results, taking into account the contribution of natural background radiation and of transit exposures. (author)

  9. Cr-39 fast neutron dosemeter based on A (n, α) converter

    International Nuclear Information System (INIS)

    Widayati, S.; Budiantari, T.

    1998-01-01

    The aim of this experiment is to obtained the response of Cr-39 as fast neutron dosemeter based on an (n, α) converter. Cr-39 was irradiated to AmBe fast neutron flux from 0.10 mSv to 2.5 mSv. Cr-39 processed by chemical etching with NaOH 20 % at temperature of 60 oC in six hours. The results of experiment showed that the response of Cr-39 based on an (n, α) converter is 6 times bigger than the response of Cr-39 without (n, α) converter. (author)

  10. A contribution to thermoluminescence dosemeter system optimisation applied to environmental monitoring around nuclear power plants

    International Nuclear Information System (INIS)

    Dies, X.; Ortega, X.; Rosell, J.

    1990-01-01

    The factors that constitute a thermoluminescence dosimetric system have been studied and optimised, with the intention of defining strategies for improving precision and accuracy of TL dosimetry systems for environmental monitoring. An optimisation technique based on fractional factorial designs permitted a reduction in the number of necessary experiments and clarified interactions between various factors. The model for fading over time showed that TL response in LiF:Mg,Ti dosemeters was independent of time between irradiation and readout, and this was applied to fading corrections in nuclear power plant environmental monitoring. (author)

  11. A new lease of life for the Farmer-Baldwin dosemeter

    International Nuclear Information System (INIS)

    Vojnovic, B.

    1984-01-01

    Replacement batteries for the widely used 'Farmer-Baldwin Sub-standard x-ray Dosemeter' (Farmer 1955), manufactured by Baldwin Industrial Controls, of Dartford, Kent, have become expensive and difficult to obtain, resulting in a number of such units being unnecessarily taken out of service. This note describes how the relatively simple addition of a DC-DC inverter can drastically reduce the maintenance costs of the instrument (MK2 version) by powering it from three commonly available 1.5 V cells, type U2 (IEC type R20). The function of the various controls on the instrument is not affected in any way. (author)

  12. Results of the European Community's beta intercomparison programme of individual dosemeters in 1986

    International Nuclear Information System (INIS)

    Bigard, T.; Sequin, H.; Chartier, J.L.; Christensen, P.; Francis, T.M.; Lembo, L.

    1988-01-01

    For over 20 years, the Commission of the European Communities, in collaboration with competent laboratories in the member states, has been conducting intercomparisons of individual dosemeters with the objective of improving technique for monitoring ionizing radiation and establishing a common basis for dose assessment within the Community. These programmes not only serve the participants with an opportunity to validate their calibration and measuring procedures but also help to create a forum in which to exchange information and discuss experience with other participants. The performance and results of such an intercomparison exercise conducted in 1986 are reported here

  13. Al2 O3:Cr,Ni: a possible thermoluminescent dosemeter

    International Nuclear Information System (INIS)

    Mariani R, Francisco; Roman B, Alvaro; Saavedra S, Renato; Ibarra S, Angel

    1996-01-01

    Results from a study on the thermoluminescent (Tl) emission from Al 2 O 3 :Cr,Ni are presented. The measurements were obtained for evaluation of the Al 2 O 3 :Cr,Ni dosimetric properties. Different crystal batches were exposed to two kind of ionizing radiation (X-ray and β - ). The Tl spectrum has a main peak with high thermal and optical stability, deviating from linearity for doses lower than 3.6 Gy. Furthermore, this material shows advantages (thermal resistance, reusability, multiple heating cycles) compared to TLD-100. Measured Al 2 O 3 :Cr,Ni properties indicate that it could be used as a dosemeter. (author)

  14. Standard X ray beams for calibration of dosemeters used in radiation protection practice

    International Nuclear Information System (INIS)

    Pernicka, F.; Michalik, V.

    1992-01-01

    Kerma in air is a widely used reference quantity specified by different calibration laboratories. Calibration of dosemeters used for individual and environmental monitoring requires a knowledge of conversion coefficients between the air kerma and an appropriate protection quantity. These were determined for sets of standard X ray beams using measured spectral distributions, calculated mean energies and effective energies obtained from HVLs measured by an ionisation chamber. There is a good agreement among these three approaches for energies down to 60-70 keV. For lower energies one can expect differences up to 10% if the coefficients are determined from the mean or effective energy instead from the spectral distribution. (author)

  15. Dose evaluation in criticality accidents using response of panasonic TL personal dosemeters (UD-809/UD-802)

    International Nuclear Information System (INIS)

    Zeyrek, C. T.; Guenduez, H.

    2012-01-01

    This study gives the results of dosimetry measurements carried out in the Silene reactor at Valduc (France) with neutron and photon personal thermoluminescence dosemeters (TLDs) in mixed neutron and gamma radiation fields, in the frame of the international accident dosimetry intercomparison programme in 2002. The intercomparison consisted of a series of three irradiation scenarios. The scenarios took place at the Valduc site (France) by using the Silene experimental reactor. For neutron and photon dosimetry, Panasonic model UD-809 and UD-802 personal TLDs were used together. (authors)

  16. Dose evaluation in criticality accidents using response of Panasonic TL personal dosemeters (UD-809/UD-802).

    Science.gov (United States)

    Zeyrek, C T; Gündüz, H

    2012-09-01

    This study gives the results of dosimetry measurements carried out in the Silène reactor at Valduc (France) with neutron and photon personal thermoluminescence dosemeters (TLDs) in mixed neutron and gamma radiation fields, in the frame of the international accident dosimetry intercomparison programme in 2002. The intercomparison consisted of a series of three irradiation scenarios. The scenarios took place at the Valduc site (France) by using the Silène experimental reactor. For neutron and photon dosimetry, Panasonic model UD-809 and UD-802 personal TLDs were used together.

  17. Study of some characteristic dosimetric of the LIF:Mg, You (JR1152C) for their employment as environmental dosemeter

    International Nuclear Information System (INIS)

    Molina Perez, D.; Diaz Bernal, E.; Prendes Alonso, M.

    1998-01-01

    As the interest grows in knowing the effects on the health of the drops dose of natural or artificial radiation, it is made but necessary a system dosimetric able to measure those dose levels accurately. P but of twenty years the dosemeters thermoluminescent (TL) they have constituted a simple and beautiful method for such mensurations. In the work the rehearsals of homogeneity, reproducibility, line lay, detection threshold, auto irradiation, residual, fading and angular dependence are described. The results demonstrate that the dosemeter satisfies the main requirements to be an employee in the environmental monitoring

  18. Validation of response simulation methodology of Albedo dosemeter; Validacao da metodologia de simulacao de resposta de dosimetro de Albedo

    Energy Technology Data Exchange (ETDEWEB)

    Freitas, B.M.; Silva, A.X. da, E-mail: bfreitas@nuclear.ufrj.br [Coordenacao do Programas de Pos-Graduacao em Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear; Mauricio, C.L.P. [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2016-07-01

    The Instituto de Radioprotecao e Dosimetria developed and runs a neutron TLD albedo individual monitoring service. To optimize the dose calculation algorithm and to infer new calibration factors, the response of this dosemeter was simulated. In order to validate this employed methodology, it was applied in the simulation of the problem of the QUADOS (Quality Assurance of Computational Tools for Dosimetry) intercomparison, aimed to evaluate dosimetric problems, one being to calculate the response of a generic albedo dosemeter. The obtained results were compared with those of other modeling and the reference one, with good agreements. (author)

  19. Neutron dosimetry inside the containment building of Spanish nuclear power plants with PADC based dosemeters

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Fuste, M.J. [Grup de Fisica de les Radiacions. Departament de Fisica. Edifici C. Universitat Autonoma de Barcelona, E-08193 Bellaterra (Spain); Domingo, C., E-mail: carles.domingo@uab.ca [Grup de Fisica de les Radiacions. Departament de Fisica. Edifici C. Universitat Autonoma de Barcelona, E-08193 Bellaterra (Spain); Amgarou, K.; Bouassoule, T.; Castelo, J. [Grup de Fisica de les Radiacions. Departament de Fisica. Edifici C. Universitat Autonoma de Barcelona, E-08193 Bellaterra (Spain)

    2009-10-15

    The Spanish Nuclear Safety Council (Consejo de Seguridad Nuclear, CSN) recommends performing neutron individual dose assignments at workplaces based on ambient dose equivalent measurements using area monitors and by estimating the amount of time that workers spend in the different monitored environments. In addition, some Spanish nuclear power plants estimate the neutron dose equivalent using albedo thermoluminescence dosemeters (TLD). In the period 2004-2006, our group, together with other research centers, participated in a project, funded by the CSN, with the support of the Spanish Nuclear Power Plants Association (UNESA), to investigate in situ which could be the best practical procedure for individual neutron dose monitoring in nuclear power plants. As part of this survey, several units of the UAB PADC based neutron dosemeter were exposed, on a methacrylate phantom simulating a human body, at four different places inside the containment building of the Asco I nuclear power plant. The influence of different types of calibration neutron fields is analysed and the dose equivalent for each point is estimated.

  20. Three-dimensional absorbed dose determinations by N.M.R. analysis of phantom-dosemeters

    International Nuclear Information System (INIS)

    Gambarini, G.; Birattari, C.; Fumagalli, M.L.; Vai, A.; Monti, D.; Salvadori, P.; Facchielli, L.; Sichirollo, A.E.

    1996-01-01

    Magnetic resonance imaging of a tissue-equivalent phantom is a promising technique for three-dimensional determination of absorbed dose from ionizing radiation. A reliable method of determining the spatial distribution of absorbed dose is indispensable for the planning of treatment in the presently developed radiotherapy techniques aimed at obtaining high energy selectively delivered to cancerous tissues, with low dose delivered to the surrounding healthy tissue. Aqueous gels infused with the Fricke dosemeter (i.e. with a ferrous sulphate solution), as proposed in 1984 by Gore et al., have shown interesting characteristics and, in spite of some drawbacks that cause a few limitations to their utilisation, they have shown the feasibility of three-dimensional dose determinations by nuclear magnetic resonance (NMR) imaging. Fricke-infused agarose gels with various compositions have been analysed, considering the requirements of the new radiotherapy techniques, in particular Boron Neutron Capture Therapy (B.N.C.T.) and proton therapy. Special attention was paid to obtain good tissue equivalence for every radiation type of interest. In particular, the tissue equivalence for thermal neutrons, which is a not simple problem, has also been satisfactorily attained. The responses of gel-dosemeters having the various chosen compositions have been analysed, by mean of NMR instrumentation. Spectrophotometric measurements have also been performed, to verify the consistence of the results. (author)

  1. Photon energy dependence of three fortuitous dosemeters from personal electronic devices, measured by optically stimulated luminescence

    International Nuclear Information System (INIS)

    Beerten, K.; Vanhavere, F.

    2010-01-01

    New data are presented with regard to the relative OSL sensitivity of three different emergency dosemeters irradiated to various photon energies approximately between 48 and 1250 keV using blue excitation light. Investigated components extracted from commonly worn objects include those from USB flash drives (alumina substrate), mobile phones (Ba-rich silicate) and credit cards (chip card module). Several basic properties have been investigated such as the overall radiation sensitivity, the shape of the decay curve and fading of the OSL signal. An increase of the sensitivity for low energies relative to 60 Co gamma rays can be observed for the three dosemeters, the increase being very pronounced for the Ba-rich component (factor of 10) and less pronounced for the chip card module (factor of 2). It is concluded that proper dose correction factors for photon energy have to be applied in order to accurately determine the absorbed dose to tissue. The OSL sensitivity to neutron irradiation was investigated as well, but this was found to be less than the gamma sensitivity. (authors)

  2. Photon energy dependence of three fortuitous dosemeters from personal electronic devices, measured by optically stimulated luminescence.

    Science.gov (United States)

    Beerten, Koen; Vanhavere, Filip

    2010-08-01

    New data are presented with regard to the relative OSL sensitivity of three different emergency dosemeters irradiated to various photon energies approximately between 48 and 1250 keV using blue excitation light. Investigated components extracted from commonly worn objects include those from USB flash drives (alumina substrate), mobile phones (Ba-rich silicate) and credit cards (chip card module). Several basic properties have been investigated such as the overall radiation sensitivity, the shape of the decay curve and fading of the OSL signal. An increase of the sensitivity for low energies relative to (60)Co gamma rays can be observed for the three dosemeters, the increase being very pronounced for the Ba-rich component (factor of 10) and less pronounced for the chip card module (factor of 2). It is concluded that proper dose correction factors for photon energy have to be applied in order to accurately determine the absorbed dose to tissue. The OSL sensitivity to neutron irradiation was investigated as well, but this was found to be less than the gamma sensitivity.

  3. State of the art in thermoluminescent dosimetry using dosemeters with automated read-out

    International Nuclear Information System (INIS)

    Regulla, D.F.

    1979-01-01

    In the beginning, the results obtained with automated read-out TLD have been quite disappointing, both for manufacturers and users. In response to this, industry then seeked advice and assistance from those experienced in the practical use of dosemeters, and the development of the second generation of automated TLD has been a common task of manufacturers and purchosers. As a preliminary achievement of development work along this line, a dosemeter has been presented by a Japanese manufacturer, meeting the requirements in quite a satisfactory way. The device is characterized by a frequency of disturbance of -5 , a microprocessor for controlling the measuring and control functions, possibility of active input of device parameters and boundary conditions, extensive self-control of operating functions, complete data protection, and thin-film detector technique. Pursuing this line of development, and taking into account future recommentations, automated thermoluminescent dosimetry does seem to be a promising alternative to current measuring techniques in personnel monitoring. (orig./RW) [de

  4. Spectral correction factors for conventional neutron dosemeters used in high-energy neutron environments

    International Nuclear Information System (INIS)

    Lee, K.W.; Sheu, R.J.

    2015-01-01

    High-energy neutrons (>10 MeV) contribute substantially to the dose fraction but result in only a small or negligible response in most conventional moderated-type neutron detectors. Neutron dosemeters used for radiation protection purpose are commonly calibrated with 252 Cf neutron sources and are used in various workplace. A workplace-specific correction factor is suggested. In this study, the effect of the neutron spectrum on the accuracy of dose measurements was investigated. A set of neutron spectra representing various neutron environments was selected to study the dose responses of a series of Bonner spheres, including standard and extended-range spheres. By comparing 252 Cf-calibrated dose responses with reference values based on fluence-to-dose conversion coefficients, this paper presents recommendations for neutron field characterisation and appropriate correction factors for responses of conventional neutron dosemeters used in environments with high-energy neutrons. The correction depends on the estimated percentage of high-energy neutrons in the spectrum or the ratio between the measured responses of two Bonner spheres (the 4P6-8 extended-range sphere versus the 6'' standard sphere). (authors)

  5. Re-Establishment of Standard Radiation Qualities for Calibration of Dosemeter in Diagnostic Radiology - RQR Series

    International Nuclear Information System (INIS)

    Asmaliza Hashim; Norhayati Abdullah; Mohd Firdaus Abd Rahman

    2016-01-01

    After repairing the high voltage (HV) generator for Philips MG165 X-Ray Machine, the reestablishment of the standard radiation qualities has been done at Medical Physics Calibration Laboratory to meet the IEC and IAEA standard. Standard radiation qualities are the important criteria for calibration of dosemeter in diagnostic radiology. Standard radiation qualities are defined as the added filtration needed to produce and the half value layer (HVL) of the beam for specifies x-ray tube kilo voltage (kV). For calibration of dosemeter in diagnostic radiology, standard radiation qualities RQR represent the beam incident on the patient in general radiography, fluoroscopy and dental application. The HVL were measured using PTW ion chamber of volume 1 cm"3 with PTW electrometer and aluminium filter with 99.9 % purity was used as additional filter for RQR and filter for HVL. The first establishment of standard radiation qualities was made in 2009 for the radiation qualities of RQR. The results of additional filter and 1st HVL from 2009 to 2016 will be discussed further in paper. The ratios of the measured HVL to the standard IEC HVL value for the RQR series also described in this paper. The details of the measurement and the results are described in this paper. (author)

  6. Characterization of workplaces in interventional radiology using active dosemeters ALARA OD

    International Nuclear Information System (INIS)

    Prlic, I.; Milkovic-Kraus, S.; Mestrovic, T.; Suric-Mihic, M.; Vrtar, M.

    2005-01-01

    Full text: Because of progressive development and extended use of interventional radiology procedures it is highly recommended that all individuals involved in the process should be aware of the potential for both stochastic and deterministic effects due to occupational exposure. Interventional radiology procedures are essentially therapeutic and are performed by various medical specialists, not only by properly educated radiologists. As the procedures are performed in such a manner that certain number of medical staff are always needed near the patient, near the x- ray unit, ensuring 'safe' working environment in such radiation x-ray field geometry is a new challenge to regular radiation protection. In this work we are not primary concerned in relatively high doses delivered to patients undergoing interventional procedures. The patient is rather regarded as a secondary radiation source which emits scattered x-rays. The working staff, moving in mixed, primary and scattered x-ray field, is expected to be exposed to higher occupational doses due to combination of extended fluoroscopy times, elevated fluoroscopy currents and larger amount of radiographic images required. The protection of both patients and staff is to be upgraded. As passive dosemetes will give us clear knowledge only about the monthly integrated occupational dose, a reasonable doubt exists about the frequency and duration, of receiving the dose. Measuring dose rate is not a part of regular passive dosemeters monitoring systems. This is why we have developed active - electronic dosemeter device which provides us with additional dosimetry data about the frequency and duration of professional exposure burden. Digital dosemeter ALARA OD will record and integrate any occupational dose including the normal radiation background in the working area. It will record the time and duration of any fluoroscopic exposure done. This gives us the data about the dose rate of occupational radiation and frequency of

  7. Viability of the Fricke dosemeter doped with methylene blue; Viabilidade do dosimetro Fricke dopado com azul de metileno

    Energy Technology Data Exchange (ETDEWEB)

    Souza, V.L.B.; Santos, C.D.A.; Rodrigues, K.R.G.; Cunha, M.S.; Figueiredo, M.D.C.; Melo, R.T. [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2009-07-01

    This work aims to find the possible utilization of the Fricke dosemeter doped with methylene blue (FMB) for the dosimetry of photodynamic therapy. The FMB was irradiated wit X rays and light emitted diodes demonstrating positive answers to the stimulus, being probably to be used for dosimetric objectives

  8. In-vivo dosimetry in radiotherapy: a comparison of the response of semiconductor and thermoluminescence (TLD700) dosemeters

    Energy Technology Data Exchange (ETDEWEB)

    Vynckier, S [Universite Catholique de Louvain, Brussels (Belgium). Cliniques Universitaires St. Luc; Greffe, J L; Loncol, T; Vanneste, F; Octave-Prignot, M; Denis, J M; De Patoul, N

    1995-12-01

    Semiconductor dosemeters and thermoluminescence dosemeters were calibrated in view of in-vivo dosimetry. Their response in a 8 MV photon beam and the respective correction factors for the treatment conditions were systematically studied. A total of 249 entrance and exit measurements with this dual detector combination were performed, mainly for treatments of the head and neck region. The resulting entrance and exit doses were compared with the expected doses at these positions, calculated on basis of the treatment and patient parameters. The results at the entrance showed a value of 1.010 (2.8% for the ratio of the measured to the calculated dose by diodes, 1.013) 4.9% for the ratio of the measured to the calculated dose by TLD and 1.003 (3.6% for the ratio of the measured dose by TLD to diodes. With respect the exit dose, the results were 0.998) 4.9%, 1.016 (7.7% and 1.019) 7.0% respectively after correction for the heterogeneity`s. Although the standard deviation for the TLD dosemeters is systematically larger than the standard deviation for the diodes, it is concluded that both dosemeters will yield similar results for-in-vivo dosimetry, if utilized under the same conditions.

  9. Technical specification of the NRPB thermoluminescent dosemeter used for the measurement of body dose and skin dose

    CERN Document Server

    Shaw, K B

    1977-01-01

    This report specifies the NRPB thermoluminescent dosemeter used for the measurement of radiation dose in tissue at a depth of 700 mg cm sup - sup 2 (body dose) and at a depth of 5-10 mg cm sup - sup 2 (skin dose).

  10. Glass compositions

    Energy Technology Data Exchange (ETDEWEB)

    France, P W

    1985-05-30

    A fluoride glass for use in the production of optical fibres has an enhanced D/H ratio, preferably such that OD:OH is at least 9:1. In the example, such a glass is prepared by treating with D/sub 2/O a melt comprising 51.53 mole per cent ZrF/sub 4/, 20.47 mole per cent BaF/sub 2/, 5.27 mole per cent LaF/sub 3/, 3.24 mole per cent AlF/sub 3/, and 19.49 mole per cent LiF.

  11. Study on routines and procedures of calibration of clinical dosemeter on gamma radiation beams at the IPEN-CNEN/SP, Brazil

    International Nuclear Information System (INIS)

    Damatto, Willian B.; Potiens, Maria da Penha A.; Santos, Gelson P.; Vivolo, Vitor

    2009-01-01

    The calibration consists in the comparison of the equipment to be calibrated with other equipment already calibrated by another standard, which means the equipment that will accomplish shall be considered secondary or tertiary, depending on the calibration that will be accomplished. As the clinical dosemeters are used for quality control services in the hospitals, these dosemeters need a reliable measurement precision. Therefore, this work intends to demonstrate the importance of the clinical dosemeter and the calibration, requiring special care face to all clinical set

  12. A low-cost personal dosemeter based on optically stimulated luminescence (OSL) of common household salt (NaCl)

    International Nuclear Information System (INIS)

    Ekendahl, Daniela; Bulánek, Boris; Judas, Libor

    2016-01-01

    Salt represents a radiation sensitive material that can be used for dosimetry. The objective of this experimental study was to test a low-cost salt dosemeter that was designed for personnel that are not radiation workers, but can operate in low probability events resulting in a serious external radiation exposure. The dosemeter is based on use of optically stimulated luminescence (OSL) of a common household salt. Attention was concentrated on its energy and angular responses. The dosemeter was fixed to the ICRU slab phantom and irradiated by photons of reference radiation qualities (ISO 4037-1) with mean energies between 33 and 1250 keV. Angular response was investigated for angles of incidence from 0° to 80° for radiation qualities of N-150 (∼118 keV) and S-Cs (∼662 keV). Single-Aliquot Regenerative-dose analytical protocol was employed for dose reconstruction. The results were evaluated with respect to H_p(10) measurement. The salt dosemeter can provide reliable or reasonably conservative H_p(10) estimates in radiation fields where photon energies > 100 keV predominate, radiation incidence angles are from 0° to 80° and also for rotational geometry. Furthermore, a personal dose reconstruction trial was demonstrated. Relative deviation between the measured and reference H_p(10) values was 5.5%. A practical disadvantage of the method is the more demanding analytical protocol. - Highlights: • Common salt has a considerable potential for dosimetry based on use of OSL. • A simple salt personal dosemeter was designed and tested. • Photon energy and angular responses were satisfactory for purposes of accidental dosimetry. • Dose reconstruction trial proved the potential for reliable estimate of personal doses.

  13. Glass: Rotary Electric Glass Furnace

    Energy Technology Data Exchange (ETDEWEB)

    Recca, L.

    1999-01-29

    Compared to conventional gas-fired furnaces, the new rotary electric furnace will increase energy efficiency while significantly reducing air emissions, product turnaround time, and labor costs. As this informative new fact sheet explains, the thousand different types of glass optical blanks produced for the photonics industry are used for lasers, telescopes, cameras, lights, and many other products.

  14. Results of film dosemeter control irradiations of German dose measurements services, 1969-1974

    International Nuclear Information System (INIS)

    Gummi, V.; Taubert, R.

    1976-01-01

    The dose measurement services of the FRG have been controlling themselves since 1961 by evaluating film dosimeters irradiated in the PTB under standard conditions. This control method is now embodied in a law by the second decree about the standardization of measuring instruments dt. 6th August 1975. During the time 1969-74 the PTB carried out more than 800 annual control irradiations of film dosimeters. In 30% of the cases the evaluation by the measuring services showed an errory higher than +50%/-30%. The dose measuring services partially diverge considerably concerning the distribution of evaluation errors. Particular difficulties seem to exist in the soft x-ray radiation with effective energies less than 30 keV, in the energy range about 100 keV, and in the evaluation of dosemeter irradiated with two different qualities of radiation (double irradiation). (orig.) [de

  15. Absorbed dose measurements in mammography using Monte Carlo method and ZrO2+PTFE dosemeters

    International Nuclear Information System (INIS)

    Duran M, H. A.; Hernandez O, M.; Salas L, M. A.; Hernandez D, V. M.; Vega C, H. R.; Pinedo S, A.; Ventura M, J.; Chacon, F.; Rivera M, T.

    2009-10-01

    Mammography test is a central tool for breast cancer diagnostic. In addition, programs are conducted periodically to detect the asymptomatic women in certain age groups; these programs have shown a reduction on breast cancer mortality. Early detection of breast cancer is achieved through a mammography, which contrasts the glandular and adipose tissue with a probable calcification. The parameters used for mammography are based on the thickness and density of the breast, their values depend on the voltage, current, focal spot and anode-filter combination. To achieve an image clear and a minimum dose must be chosen appropriate irradiation conditions. Risk associated with mammography should not be ignored. This study was performed in the General Hospital No. 1 IMSS in Zacatecas. Was used a glucose phantom and measured air Kerma at the entrance of the breast that was calculated using Monte Carlo methods and ZrO 2 +PTFE thermoluminescent dosemeters, this calculation was completed with calculating the absorbed dose. (author)

  16. Personal Dosemeter of Thermal Neutron Using A Cr-39 Detector with Filter Natural LiF

    International Nuclear Information System (INIS)

    Sofyan, Hasnel; Thamrin, M.Thoyib

    1996-01-01

    The research of personal dosemeter for thermal neutron using Cr-39 detector with different thicknesses of natural LiF filter was carried out. The irradiation of Cr-39 detector with neutron source from reactor research TRIGA mark II of Rikkyo University Tokyo, Japan. Nuclear track was counted by automatic method with ASPECT ver.4.22 Series A4T124 software and manual method for correction. The result of research, the maximum of nuclear tracks was obtained at 8 mm of LiF filter was 10 mm with 11,630x10E-5 track/neutron for air radiation. And on phantom radiation, the thickness of filter was 10 mm with 11,630x10E-5 track/neutron. Its values were 3.6 and 7.5 bigger than the response of Cr-39 non filter in air and on phantom radiation, respectively

  17. Automation of radiation dosimetry using PTW dosemeter and LabVIEWTM

    International Nuclear Information System (INIS)

    Weiss, C.; Al-Frouh, K.; Anjak, O.

    2011-01-01

    Automation of UNIDOS 'Dosemeter' using personal computer (PC) is discussed in this paper. In order to save time and eliminate human operation errors during the radiation dosimetry, suitable software, using LabVIEW TM graphical programming language, was written to automate and facilitate the processes of measurements, analysis and data storage. The software calculates the calibration factor of the ionization chamber in terms of air kerma or absorbed dose to water according to IAEA dosimetry protocols. It also has the ability to print a calibration certificate. The obtained results using this software are found to be more reliable and flexible than those obtained by manual methods previously employed. Using LabVIEW TM as a development tool is extremely convenient to make things easier when software modifications and improvements are needed.

  18. Characterization of an active dosemeter according to IEC 61526:2010

    International Nuclear Information System (INIS)

    Cardoso, J.; Santos, L.; Santos, J.A.M.; Alves, J.G.; Oliveira, C.

    2016-01-01

    The active personal dosemeter, RaySafe i2, allows the measurement and record of Hp(10) in real time, every second, via wireless technology for real-time display on a portable computer and/or a local network. The system seems particularly attractive for individual monitoring at clinical facilities where high intensity and varying radiation fields may occur, as it enables the user to acknowledge and optimize the dose and dose rate values in real time for each procedure. Prior to its use, the system was characterized at the Metrology Laboratory of Ionizing Radiation of IST-LPSR aiming at the metrological characterization of the system in accordance with IEC 61526:2010 for metrological control purposes and to verify the technical specifications stated by the manufacturer. (authors)

  19. Contribution to the development of a fast neutron dosemeter SAD 1

    International Nuclear Information System (INIS)

    Jung, M.; Francois, H.; Heilmann, C.; Demoulin, R.; Kappler, A.; Oppel, R.

    1983-01-01

    The dosemeter response to various neutron fluxes from known monoenergetic sources has been calibrated in order to optimize this response, especially as regards the conversion factor for the hydrogeneous material used. Alongside these microscopic measurements, an automatic measuring system has been developed, based on detecting the amount of silver left along the tracks of recoil protons formed in (n,p) reactions. It is necessary to have a complete calibration of the converter response xsub(D), which is related directly to the energy loss in the emulsion. For this purpose we have designed an X-ray fluorescence apparatus which determines the residual silver by exciting the 22.5 and 25 keV lines of silver [fr

  20. Track-etch dosemeter response to neutrons up to 300 MeV

    International Nuclear Information System (INIS)

    Devine, R.T.; Walker, S.; Staples, P.; Duran, M.; Mundis, R.; Miller, J.

    1996-01-01

    Electro-chemical and chemical track-etch dosemeters were obtained from commercial suppliers and exposed to neutrons produced at the LANTF WNR white neutron source at 15 degree with no shielding and filtered by polyethylene blocks of 2.5, 5.1, 10.2, 20.3 and 40.6 cin thickness. The neutron spectrum was determined using calculations. Mean energies from 28 to 300 MeV were produced. Dose was calculated from the NCRP-38 flux-to-dose conversion. The results are compared with NTA film which was exposed in the same configuration. The response of track etch dosimeters was found to reach a minimum and then rise as the average neutron energy increased. The response of the NTA film increased as the neutron energy increased

  1. Measurement analysis using the Fricke dosemeter; Analise de medicoes com o dosimetro Fricke

    Energy Technology Data Exchange (ETDEWEB)

    Pedrosa, G A.C. , [Instituto Nacional de Metrologia (INMETRO), Rio de Janeiro, RJ (Brazil); Dantas, C.C. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear], e-mail: ccd@ufpe.br; Campos, C.A. [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)], e-mail: auster@elogica.com.br

    2003-07-01

    The Fricke dosemeter has been used for absolute determination of the radiation dose between 40 and 350 Gy for X-rays, Gamma rays and fast electrons energies. The great inconvenient of that dosimetric system is the impossibility of using for measurements of exposure or low dose rates. A Fricke dosimetry system was implanted at the Nuclear Sciences Regional Center (CRCN), in Recife, Pernambuco state, Brazil, for the determination of radiation doses for spectrometry and mass dosimetry with plasma source. The statistical analysis of the obtained results have shown that using the spectrometric method that system cna be used for maintenance of factors of CRCN standard calibrations and the dose assessment thru mail system of radiotherapy centers of the country.

  2. Photon beam audits for radiation therapy clinics: A pilot mailed dosemeter study in Turkey

    International Nuclear Information System (INIS)

    Yegingil, Z.; DeWerd, L. A.; Davis, S. D.; Hammer, C.; Kunugi, K.

    2012-01-01

    A thermoluminescent dosemeter (TLD) mailed dose audit programme was performed at five radiotherapy clinics in Turkey. The intercomparison was organised by the Univ. of Wisconsin Radiation Calibration Laboratory (UWRCL), which was responsible for the technical aspects of the study including reference irradiations, distribution, collection and evaluation. The purpose of these audits was to perform an independent dosimetry check of the radiation beams using TLDs sent by mail. Acrylic holders, each with five TLD chips inside and instructions for their irradiation to specified absorbed dose to water of 2 Gy, were mailed to all participating clinics. TLD irradiations were performed with a 6 MV linear accelerator and 60 Co photon beams. The deviations from the TL readings of UWRCL were calculated. Discrepancies inside the limits of ±5 % between the participant-stated dose, and the TLD-measured dose were considered acceptable. One out of 10 beams checked was outside this limit, with a difference of 5.8 %. (authors)

  3. Neutron spectrometry and dosimetry measurement at workplaces for calibration of individual PGP-DIN dosemeters

    International Nuclear Information System (INIS)

    Itie, C.; Muller, H.; Asselineau, B.; Medioni, R.; Crovisier, P.; Valier-Bradier, P.; Groetz, J.E.; Piot, J.

    2003-01-01

    Measurements to determine new coefficients for individual neutron dosimeters PGP-DIN complying with the ICRP 60 recommendations were performed at two workplaces at the CEA of Valduc: a storage room and a plutonium reprocessing plant. Two spectrometry campaigns were performed allowing a better assessment of doses received by operators working at these workplaces. Neutron energy fluence and ambient dose equivalent rate H * (10) distributions were measured as function of neutron energy by using the ROSPEC device and BONNER spheres spectrometer. The radiation field being mixed neutron and gamma, the gamma component was also evaluated: neutron and photon dose-rate meters were used to evaluate the ambient dose rate equivalent. Individual dosemeters were positioned on an ISO water slab phantom. In addition, calculations were performed using the MCNP simulation code for different configurations. (authors)

  4. Thermoluminescent dosemeter in a X-ray diffractometer; Dosimetria termoluminiscente en un difractometro de rayos X

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza A, D.; Gonzalez M, P.; Falcon B, T. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, Mexico D.F. (Mexico); Castano, V.M. [Instituto de Fisica, UNAM, Laboratorio Juriquilla, A.P. 1-1010, C.P. 76001, Queretaro (Mexico)

    1999-07-01

    In this work it was presented the results obtained of the dosimetry which was realized in a X-ray diffractometer for powders, trademark Siemens D5000, using the thermoluminescent signal generated by the X-rays in the commercial dosemeter TLD-100 of Harshaw, US. In according to the results obtained, the radiation quantity received by an analysed material in the diffractometer, will be proportional to exposure time and it can vary from unities until tenths of grays. These results are very outstanding when are analysed crystalline materials in a diffractometer, for knowing the present crystalline phases, mainly if these are highly sensitive to the ionizing radiation, as it is the case of the thermoluminescent materials. (Author)

  5. Evaluation of the kinetic parameters of CaF2:Tm (TLD-300) thermoluminescence dosemeters

    International Nuclear Information System (INIS)

    Azorin, Juan; Gutierrez, Alicia; Furetta, Claudio

    1989-01-01

    The kinetic parameters of the first, third and fifth peaks of CaF 2 :Tm (TLD-300) dosemeters were determined experimentally using methods based on initial rise, peak shape, different heating rates, isothermal decay and numerical fitting method and a comparison was made between the results obtained. The average activation energy values determined by the methods used here were 0.72, 1.16 and 1.77 eV, with mean values for the frequency factor of 2.58 x 10 8 , 2.89 x 10 13 and 6.16 x 10 16 s -1 for the first, third and fifth peaks respectively. The values of activation energy obtained for each peak using the different methods covered a spread of about 4%. However, the spread for each of the frequency factors was very high. (author)

  6. Performance of Panasonic ZP-1460 Electronic Personal Dosemeter under Exposure Conditions Likely to be Found at Fukushima Daiichi Nuclear Power Plant

    Science.gov (United States)

    Tsujimura, Norio; Yoshida, Tadayoshi; Hoshi, Katsuya; Momose, Takumaro

    A study on the performance of the Panasonic ZP-1460 electronic personal dosemeter, the model used in the aftermath of the Fukushima Daiichi nuclear power plant accident in March 2011, was conducted under actual exposure situations likely encountered in the plant. The tests pertained to (1) the dose rate response over dose rates >100 mSv/h and (2) the angular response on an anthropomorphic phantom exposed to the rotational and isotropic irradiation geometries. The test results confirmed that the dosemeter provides Hp(10) as a reasonably close estimate of the effective dose for any exposure geometries. The dosemeter response data evaluated in this study can be utilized for converting dosemeter readings to the absorbed dose to any organs and tissues for epidemiologic purposes.

  7. Nitrate glass

    International Nuclear Information System (INIS)

    Kirilenko, I.A.; Vinogradov, E.E.

    1977-01-01

    Experimental evidence on behaviour of nitrate glasses is reviewed in terms of relationships between the presence of water in vitrescent nitrate systems and the properties of the systems. The glasses considered belong to systems of Mg(NO 3 ) 2 - Nd(NO 3 ) 3 ; Hg(NO 3 ) 2 -Nd(NO 3 ) 3 ; NaNO 3 -Mg(NO 3 ) 2 -Nd(NO 3 ) 3 ; M-Zn(NO 3 ) 3 , where M is a mixture of 20% mass NaNO 3 and 80% mass Mg(NO 3 ) 2 , and Zn is a rare earth ion. Nitrate glass is shown to be a product of dehydration. Vitrification may be regarded as a resusl of formation of molecular complexes in the chain due to hydrogen bonds of two types, i.e. water-water, or water-nicrate group. Chain formation, along with low melting points of the nitrates, hinder crystallization of nitrate melts. Provided there is enough water, this results in vitrification

  8. EURADOS intercomparisons in external radiation dosimetry: similarities and differences among exercises for whole-body photon, whole-body neutron, extremity, eye-lens and passive area dosemeters

    International Nuclear Information System (INIS)

    Romero, Ana M.; Grimbergen, Tom; McWhan, Andrew; Stadtmann, Hannes; Fantuzzi, Elena; Clairand, Isabelle; Neumaier, Stefan; Dombrowski, Harald; Figel, Markus

    2016-01-01

    The European Radiation Dosimetry Group (EURADOS) has been organising dosimetry intercomparisons for many years in response to an identified requirement from individual monitoring services (IMS) for independent performance tests for dosimetry systems. The participation in intercomparisons gives IMS the opportunity to show compliance with their own quality management system, compare results with other participants and develop plans for improving their dosimetry systems. In response to growing demand, EURADOS has increased the number of intercomparisons for external radiation dosimetry. Most of these fit into the programme of self-financing intercomparisons for dosemeters routinely used by IMS. This programme is being coordinated by EURADOS working group 2 (WG2). Up to now, this programme has included four intercomparisons for whole-body dosemeters in photon fields, one for extremity dosemeters in photon and beta fields, and one for whole-body dosemeters in neutron fields. Other EURADOS working groups have organised additional intercomparisons including events in 2014 for eye-lens dosemeters and passive area dosemeters for environmental monitoring. In this paper, the organisation and achievements of these intercomparisons are compared in detail focusing on the similarities and differences in their execution. (authors)

  9. Determination of isodose curves in Radiotherapy using an Alanine/ESR dosemeter; Determinacion de curvas de isodosis en Radioterapia usando un dosimetro de Alanina/ESR

    Energy Technology Data Exchange (ETDEWEB)

    Chen, F.; Baffa, O.; Graeff, C.F.O. [Departamento de Fisica e Matematica. Universidade de Sao Paulo FFCLRP. 14040-901 Ribeirao Preto-SP (Brazil)

    1998-12-31

    It was studied the possible use of an Alanine/ESR dosemeter in the isodose curves mapping in normal treatments of Radiotherapy. It was manufactured a lot of 150 dosemeters with base in a mixture of D-L Alanine dust (80 %) and paraffin (20 %). Each dosemeter has 4.7 mm diameter and 12 mm length. A group of 100 dosemeters of the lot were arranged inside 50 holes of the slice 25 of the phantom Rando Man. The phantom irradiation was realized in two opposed projections (AP and PA) in Co-60 equipment. A group of 15 dosemeters was take of the same lot for obtaining the calibration curve in a 1-20 Gy range. After irradiation the signal of each dosemeter was measured in an ESR spectrometer operating in the X-band ({approx} 9.5 GHz) and the wideness of Alanine ESR spectra central line was correlated with the radiation dose. The wideness dose calibration curve resulted linear with a correlation coefficient 0.9996. The isodose curves obtained show a profile enough similar at comparing with the theoretical curves. (Author)

  10. Study of a selection of 10 historical types of dosemeter: variation of the response to Hp(10) with photon energy and geometry of exposure.

    Science.gov (United States)

    Thierry-Chef, I; Pernicka, F; Marshall, M; Cardis, E; Andreo, P

    2002-01-01

    An international collaborative study of cancer risk among workers in the nuclear industry is tinder way to estimate direetly the cancer risk following protracted low-dose exposure to ionising radiation. An essential aspect of this study is the characterisation and quantification of errors in available dose estimates. One major source of errors is dosemeter response in workplace exposure conditions. Little information is available on energy and geometry response for most of the 124 different dosemeters used historically in participating facilities. Experiments were therefore set up to assess this. using 10 dosemeter types representative of those used over time. Results show that the largest errors were associated with the response of early dosemeters to low-energy photon radiation. Good response was found with modern dosemeters. even at low energy. These results are being used to estimate errors in the response for each dosemeter type, used in the participating facilities, so that these can be taken into account in the estimates of cancer risk.

  11. X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy - Part 4: Calibration of area and personal dosemeters in low energy X reference radiation fields

    International Nuclear Information System (INIS)

    2004-01-01

    ISO 4037 consists of the following parts, under the general title X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy: Part 1: Radiation characteristics and production methods; Part 2: Dosimetry for radiation protection over the energy ranges from 8 keV to 1,3 MeV and 4 MeV to 9 MeV; Part 3: Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence; Part 4: Calibration of area and personal dosemeters in low energy X reference radiation fields. This part 4. of ISO 4037 gives guidelines on additional aspects of the characterization of low energy photon radiations. This part of ISO 4037 also describes procedures for calibration and determination of the response of area and personal dose(rate)meters as a function of photon energy and angle of incidence. This part of ISO 4037 concentrates on the accurate determination of conversion coefficients from air kerma to Hp(10) and H*(10) for the spectra of low energy photon radiations. As an alternative to the use of conversion coefficients, the direct calibration in terms of these quantities by means of appropriate reference instruments is described

  12. The use of TLD-700H dosemeters in the assessment of external doses at the former Semipalatinsk nuclear test site.

    Science.gov (United States)

    Hill, P; Dederichs, H; Pillath, J; Schlecht, W; Hille, R; Artemev, O; Ptitskaya, L; Akhmetov, M

    2002-01-01

    The joint projects performed since 1995 by the Jülich Research Centre in co-operation with the Kazakh National Nuclear Centre in the area of the former nuclear test site near Semipalatinsk, in eastern Kazakhstan, have assessed the current dose rate of the population at and around the test site, as well as determining retrospectively the dose rate of persons affected by the atmospheric tests. Measurements of the population by personal dosemeters depend on reliably wearing these dosemeters over prolonged periods of time, and of a sufficient dosemeter return. In the past, such measurements have been particularly successful whenever short wearing times were possible. This requires high sensitivity of the dosemeters. The suitability of the highly sensitive TLD material of the BICRON TLD 700H type for such personal dosimetry measurements was investigated. It was tested in practical field application at the Semipalatinsk nuclear test site in September 2000. Initial results are available from individual doses received by a group of geologists and a group of herdsmen at the test site. For the first time, the individual dose was measured directly in these population groups. Detection limits below 1 microSv permit informative measurements for wearing times of less than two weeks. Most individual doses did not arise significantly out of local fluctuations of natural background. A conservative assessment from the aspect of practical health physics yielded a mean personal dose of 0.55 microSv per day for the herdsmen, whereas the geologists received a mean personal dose of 0.45 microSv per day. For an annual exposure period of typically, about three months, the radiation dose received by the persons investigated, in addition to the natural radiation exposure, is thus well below the international limit value of 1 mSv x a(-1) for the population dose.

  13. New ICRU quantities for the environmental and individual monitoring. Standardization of individual dosemeters by using external beams of photon radiation

    International Nuclear Information System (INIS)

    Brosed, A.; Delgado, A.; Granados, C. E.

    1987-01-01

    The quantities introduced by ICRU for the radiological monitoring are commented, specially those implied in individual protection against external photons. A procedure is proposed in order to standardize the individual dosemeters by using the kerma in air references of CIEMAT-JEN. The reference radiation beams are described in connection with ISO standards. Provisional values are selected for the appropriate conversion and correction factors. (Author) 23 refs

  14. Preparation of the FXG gel dosemeter and studying its response for low and medium energy X-rays

    International Nuclear Information System (INIS)

    Bero, M.; Kharita, M. H.

    2008-02-01

    Gel dosimetry method was found to be capable of addressing complicated issues related to dose measurements particularly in modern sophisticated radiotherapy applications. Ferrous-sulphate Xylenol-orange and Gelatin (FXG) radiochromic gel dosemeter is one of the systems used for such applications. Some chemical dosemeters show different response for low and medium energies X-rays in comparison with high energy-photons. The energy and dose rate dependence of the FXG dose response was examined. In addition to the detector response other important dosimetric properties of the system were investigated for different X-ray beam qualities with tube voltages in the range 100 - 300 kv. An orthovoltage X-ray therapy unit was used to irradiate standard sized samples of FXG from different batches for radiation doses in the range 0 - 8 Gy. This work includes in the first stage the preparation of the radiochromic gel dosemeter (FXG) as well as its calibration in gamma radiation field. Furthermore, the stability and reproducibility of measurements were tested. The obtained results were found to be suitable as a basis to carry on the next stage of this study. The second phase was centred about the delivery of radiation doses from X-ray source that has increasing energy and evaluating the gel material properties as a dosemeter in this case, with concentration on finding the changes of the gel material response with the changes in the applied X-ray energy. Therefore establishing the response radiation energy dependence and comparing the measurement results with other results taken from other known dosimetry system such as ion chambers. Experiments shows that the FXG gel detector has a dynamic rage suitable for the dose delivered in radiotherapy treatment; its response as a function of the dose rate is also stable in the range of radiation energies applied.(Author)

  15. Study of radioactive sources accumulation with application of thermoluminescence dosemeters on the base of alkaline earth metals sulfates

    International Nuclear Information System (INIS)

    Tokbergenov, I.; Sadykov, T.

    2001-01-01

    Methodic for study of accumulation and distribution of radioactive sources in a nature objects is developed. An essence of the method consists of in that quantity of accumulated radioactive sources in a nature objects is defining by absorption dose measured with help of thermoluminescent dosemeters on the base of alkaline earth metals sulfates such as CaSO 4 :Dy and SrSO 4 :Eu

  16. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of high temperature peaks in TLD-100 dosemeters

    International Nuclear Information System (INIS)

    Flores M, E.; Avila, O.; Rodriguez V, M.; Massillon, J.L.G.; Buenfil A, E.; Ruiz T, C.; Brandan, M.E.; Gamboa De Buen, I.

    2007-01-01

    This work presents measures of relative thermoluminescent efficiency of those high temperature peaks of TLD-100 dosemeters exposed to protons of 1.5 MeV and to helium nuclei of 3 and 7.5 MeV. A rigorous reading and of deconvolution protocol was used for the calculation of the TL efficiencies. Additionally an Excel program that facilitated the deconvolution adjustment process of the glow curves was elaborated. (Author)

  17. CRYSTALLIZATION IN MULTICOMPONENT GLASSES

    Energy Technology Data Exchange (ETDEWEB)

    KRUGER AA; HRMA PR

    2009-10-08

    In glass processing situations involving glass crystallization, various crystalline forms nucleate, grow, and dissolve, typically in a nonuniform temperature field of molten glass subjected to convection. Nuclear waste glasses are remarkable examples of multicomponent vitrified mixtures involving partial crystallization. In the glass melter, crystals form and dissolve during batch-to-glass conversion, melter processing, and product cooling. Crystals often agglomerate and sink, and they may settle at the melter bottom. Within the body of cooling glass, multiple phases crystallize in a non-uniform time-dependent temperature field. Self-organizing periodic distribution (the Liesegnang effect) is common. Various crystallization phenomena that occur in glass making are reviewed.

  18. Crystallization In Multicomponent Glasses

    International Nuclear Information System (INIS)

    Kruger, A.A.; Hrma, P.R.

    2009-01-01

    In glass processing situations involving glass crystallization, various crystalline forms nucleate, grow, and dissolve, typically in a nonuniform temperature field of molten glass subjected to convection. Nuclear waste glasses are remarkable examples of multicomponent vitrified mixtures involving partial crystallization. In the glass melter, crystals form and dissolve during batch-to-glass conversion, melter processing, and product cooling. Crystals often agglomerate and sink, and they may settle at the melter bottom. Within the body of cooling glass, multiple phases crystallize in a non-uniform time-dependent temperature field. Self-organizing periodic distribution (the Liesegnang effect) is common. Various crystallization phenomena that occur in glass making are reviewed.

  19. Recycling of Glass

    DEFF Research Database (Denmark)

    Christensen, Thomas Højlund; Damgaard, Anders

    2011-01-01

    Glass is used for many purposes, but in the waste system glass is predominantly found in terms of beverage and food containers with a relatively short lifetime before ending up in the waste. Furthermore there is a large amount of flat glass used in building materials which also ends up in the waste...... system; this glass though has a long lifetime before ending up in the waste. Altogether these product types add up to 82% of the production of the European glass industry (IPCC, 2001). Recycling of glass in terms of cleaning and refilling of bottles as well as the use of broken glass in the production...... of new glass containers is well established in the glass industry. This chapter describes briefly howglass is produced and howwaste glass is recycled in the industry. Quality requirements and use of recycled products are discussed, as are the resource and environmental issues of glass recycling....

  20. The fast neutron response of 7LiF thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Knipe, A.D.

    1990-02-01

    A series of experiments was performed in 1982 to determine the neutron energy response of the 7 LiF thermoluminescent dosemeter (TLD) employed in European zero power fast reactor gamma-ray energy deposition studies. Preliminary results of this work were included in a 1985 International experimental data-base of TLD neutron sensitivities and provided the most consistent set of data within the 7 LiF compilation. A more detailed interpretation of these data has improved the results still further, giving a mean relative neutron to gamma efficiency of 0.118±0.005. The main objective of this re-evaluation was to establish recommended neutron energy response values to replace a 1974 data set for the analysis of in-core fast reactor measurements. This was achieved by combining the mean experimental relative efficiency of 0.118 with calculated energy dependent kerma factors. The kerma factors for the TLD were based on US National Bureau of Standards values and a composition determined by chemical analysis. Adoption of the revised neutron energy response data set produces a small increase in the measured gamma-ray energy deposition of typically 2% relative to the 1974 data. However, more importantly, the detailed analysis of the experimental response data has significantly improved confidence in the neutron corrections applied to in-core TLD gamma-ray energy deposition measurements. (author)

  1. Evaluation of the directional dose equivalent H,(0.07) for ring dosemeters

    International Nuclear Information System (INIS)

    Alvarez R, J.T.; Tovar M, V.M.

    2006-01-01

    The personnel dosimetry laboratory (LDP) of the Metrology department received an user's of radiation beta application that incidentally had irradiated 14 couples of ring dosemeters for extremities of the type TLD-100 given by the LDP. This sample of 14 couples of rings tentatively it was irradiated in the months of July-August of the year 2004, and he requested in an expedite way the evaluation of the received dose equivalent. The LSCD builds two calibration curves in terms of the directional dose equivalent H'(0.07) using two sources patterns of 90 Sr- 90 Y for beta radiation: one of 74 MBq and another of 1850 MBq with traceability to the PTB. The first curve in the interval of 0 to 5 mSv, the second in the range of 5 to 50 mSv, taking into account effects by positioned of the rings in the phantom. Both calibration curves were validated by adjustment lack, symmetry of residuals and normality of the same ones. It is evaluated and analyzing the H'(0.007) for these 14 couples of rings using the Tukey test of media of a single road. It was found that the H , its could be classified in 4 groups, and that the probability that its has irradiated in a random way it was smaller to the level at α = 0.05. (Author)

  2. Examination of the long-term stability of radiation survey meters and electronic pocket dosemeters

    International Nuclear Information System (INIS)

    Chida, K.; Nishimura, Y.; Sato, Y.; Endo, A.; Sakamoto, M.; Hoshi, C.; Zuguchi, M.

    2008-01-01

    To describe the stability of radiation survey meters (RSMs) and electronic pocket dosemeters (EPDs), we examined 28 EPDs and 24 RSMs: 12 used NaI(Tl) scintillation RSMs and 12 used Geiger-Muller (GM) RSMs. We used simple methods for the relative calibration of the 24 RSMs and 28 EPDs. The RSM and EPD measurements were compared with a calibrated RSM and EPD (reference: traceable from the national standard of exposure) using a homemade measurement device to maintain the reproducibility of the measurements with reference radiation sources (i.e. 137 Cs, 90 Sr and 67 Ga). The response of RSMs and EPDs, especially after prolonged use, should be checked periodically. In particular, GMRSMs that have been in use for many years have very low sensitivity and poor reproducibility. Our simple method for the relative calibration of RSMs and EPDs was shown to be effective for quality assurance purposes in checking RSMs and EPDs. We recommend regular checks and calibration for sustained performance of RSMs and EPDs. (authors)

  3. The effect of radiation on bioluminescent bacteria: possible use of luminescent bacteria as a biological dosemeter

    International Nuclear Information System (INIS)

    Mantel, J.; Freidin, M.; Perry, H.

    1983-01-01

    The purpose of the study was to investigate the response of the bioluminescent Photobacterium phosphoreum to radiation, and the possible use of the bacteria as a biological radiation dosemeter, i.e. a water-equivalent biological system that will compare beams not merely on the basis of absorbed dose, but also have intrinsic RBE values for different radiation beams. Samples were irradiated by a 12 MeV electron beam at a dose rate of 3.0 Gy min -1 , by 60 Co gamma rays at 2.85 Gy min -1 , and by 100 kVsub(p) x-rays at a dose rate of 2.13 Gy min -1 . To study dose-rate dependence, the survival fraction was obtained for a 12 MeV electron beam at 0.50 and 12 Gy min -1 for 20.0 Gy. The survival fraction proved to be independent of dose rate in this range. The results presented in this work indicate that by using bioluminescent bacteria, RBE measurements can be markedly simplified and the results interpreted unequivocally. (U.K.)

  4. CHARACTERIZATION OF A THIN SILICON SENSOR FOR ACTIVE NEUTRON PERSONAL DOSEMETERS.

    Science.gov (United States)

    Takada, M; Nunomiya, T; Nakamura, T; Matsumoto, T; Masuda, A

    2016-09-01

    A thin silicon sensor has been developed for active neutron personal dosemeters for use by aircrews and first responders. This thin silicon sensor is not affected by the funneling effect, which causes detection of cosmic protons and over-response to cosmic neutrons. There are several advantages to the thin silicon sensor: a decrease in sensitivity to gamma rays, an improvement of the energy detection limit for neutrons down to 0.8 MeV and an increase in the sensitivity to fast neutrons. Neutron response functions were experimentally obtained using 2.5 and 5 MeV monoenergy neutron beams and a (252)Cf neutron source. Simulation results using the Monte Carlo N-Particle transport code agree quite well with the experimental ones when an energy deposition region shaped like a circular truncated cone is used in place of a cylindrical region. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Environmental gamma-ray dose measurements with thermoluminescence dosemeters (TLD) and environmental radiation characteristics

    International Nuclear Information System (INIS)

    Kanematsu, Seiko

    1999-01-01

    It is important to evaluate environmental gamma-ray exposure both at work and home in order to assess people's collective dosages. Environmental gamma radiation was measured for air-absorbed dose with a thermoluminescence dosemeter at various points in the workplace and Ningyotoge, and workplace radiation characteristics were analyzed. From the results, the public dose due to gamma rays generated artificially was assessed to be sufficiently lower than the annual limit. For indoor environments of the workplace, the maximum dosage rate among measured values was 97 nGy/h and the minimum value was 70 nGy/h, the average over one year was 83 nGy/h. The average annual outdoor dosage for a year was 82 nGy/ h. In Ningyotoge, the maximum was 103 nGy/h, minimum 60 nGy/h, and average 88 nGy/h. These values depend on the nature of the soil and weather factors, showing higher values in the summer than in the winter in the workplace. There was no significant difference in the dosage rate in houses and the workplace. (author)

  6. Kinetics of light sum collection in solid dosemeters with several trapping levels

    International Nuclear Information System (INIS)

    Vlasov, V.K.; Tarasov, M.Yu.

    1983-01-01

    On the basis of a stochastic model of filling up the electron-hole capture centres following irradiation, the kinetics of light sum accumulation in crystallophosphors with any number of capture levels has been considered. Using as an example a crystallophosphor with two hole- and two electron capture centres, solution of equations for the kinetics of light sum accumulation in solid dosemeters is presented. It is shown that in the presence of two competing capture centres the filling-up of one of the traps is always described by the function with a bent and superlinear section, whereas the filling-up of the competing trap is described by the function without a bent. The dose-effect functional relationship for competing traps does not depend either on the energetic depth of the trap or absolute values of capture micro cross-sections, but depends solely on relative values of macro- and micro cross-sections for competing traps. The theoretical model has been checked when studying radiothermoluminescence of synthetic quartz. The experimental results are shown to agree well with the model suggested

  7. Measurement of indoor radon Concentrations in Osaka, Nara, Wakayama and Hyogo with passive dosemeters

    International Nuclear Information System (INIS)

    Mori, Toshiaki; Hori, Yasuharu; Takeda, Atsuhiko; Iwasaki, Tamiko; Uchiyama, Masahumi; Fujimoto, Kenzo; Kankura, Takako; Kobayashi, Sadayosi.

    1989-01-01

    Indoor radon concentrations of 792 houses in Osaka, Nara, Wakayama and Hyogo were measured by the passive dosemeter which was developed in Karlsruhe Nuclear Research Center in West Germany. Each house was measured at two places for successive two periods of six months to obtain annual average exposure due to radon daughters. The arithmetic mean concentration of all houses was 45.2 Bq/m 3 with a standard deviation of 27.2; the geometric mean, 40.7 Bq/m 3 and the median, 39 Bq/m 3 . The distribution of the radon levels was approximately log-normal with 80% of houses having radon concentrations less than 60 Bq/m 3 . The seasonal variation of the mean radon concentration was evident between the former period including winter value of 45 Bq/m 3 and the latter including summer value of 32 Bq/m 3 . The indoor radon concentrations of wooden houses were found to have the widest distribution with the highest value of 371 Bq/m 3 . The highest value obtained in the ferro-concrete house was 118 Bq/m 3 . Twelve houses having indoor radon concentrations higher than 120 Bq/m 3 were all Japanese traditional wooden houses with walls made of soil. (author)

  8. Performance of CVD diamond as an optically and thermally stimulated luminescence dosemeter

    International Nuclear Information System (INIS)

    Preciado-Flores, S.; Schreck, M.; Melendrez, R.; Chernov, V.; Bernal, R.; Cruz-Vazquez, C.; Cruz-Zaragoza, E.; Barboza-Flores, M.

    2006-01-01

    Diamond is a material with extreme physical properties. Its radiation hardness, chemical inertness and tissue equivalence qualify it as an ideal material for radiation dosimetry. In the present work, the optically stimulated luminescence (OSL) and thermoluminescence (TL) characteristics of a 10 μm thick CVD diamond (polycrystalline diamond films prepared by chemical vapor deposition) film were studied in order to test its performance as a beta radiation dosemeter. The TL response is composed of four main TL glow peaks; two of these are in the range of 150-200 deg. C and two additional peaks in the 250-400 deg. C temperature range. The integrated TL as a function of radiation dose is linear up to 100 Gy and increases with increasing dose exposure. The dose dependence of the integrated OSL exhibits a similar behavior. The observed OSL/TL behavior for the CVD diamond film clearly demonstrate its capability for applications in radiation dosimetry with special relevance in medical dosimetry owing to the diamond's intrinsic material properties. (authors)

  9. On optically stimulated luminescence properties of household salt as a retrospective dosemeter

    International Nuclear Information System (INIS)

    Timar-Gabor, A.; Trandafir, O.

    2013-01-01

    Thermoluminescence (TL) and optically stimulated luminescence (OSL) in the UV (270-370 nm) spectral region have been investigated for five types of table salt (NaCl) available in Romanian supermarkets with a view to applying them in retrospective dosimetry. The salt samples gave bright TL signals with two main peaks at ∼ 100 deg. C and at 300 or 260 deg. C, depending on the origin of the salt and bright OSL signals under continuous stimulation with blue light. The OSL signal (stimulated at 100 deg. C after a pre-heat of 10 s at 150 deg. C) was used for investigations in a standard multiple aliquot procedure. The dose- response was found to be linear in the dose range investigated (up to ∼ 100 mGy) and the lower limit of detection for the samples varied from ∼ 0.01 to 14 mGy. These characteristics, along with the widespread abundance and low cost of household salt, confirm its potential as a retrospective dosemeter. (authors)

  10. Thermoluminescent and optical processes in alkaline halogenides dosemeters contaminated with Europium

    International Nuclear Information System (INIS)

    Barboza F, M.; Melendrez, R.; Castaneda, B.; Pedroza M, M.; Chernov, V.; Perez S, R.; Aceves, R.

    2000-01-01

    Recent research results are presented about the properties of the optical processes of photo transferred thermoluminescence (TLFT), optical whitening (BO), thermoluminescence induced by light (TLL) and its effect in the thermoluminescent curve (Tl) produced by ionizing and non-ionizing radiation. The systematic analysis of all these processes, acquires a singular importance due that actually the alkaline halogenide crystals are object of intense investigations which analyse their potential applications as detectors and radiation dosemeters through stimulated optical luminescence techniques or thermoluminescence. The obtained data show that the Tl curve of material with this nature can be enormously affected by exposure of phosphorus to the environmental light or UV. This is in part due to liberation processes of charge bearers are shouted and makes a subsequent trapping in less temperature traps; at the same time that induce changes in the intensity of determined Tl bands. Additionally, also it is observed that mentioned phenomena are related as with wavelength of incident light as of the illumination time. Finally, the obtained information allows to conclude that although the illumination effect is extremely complex, it is associated and can be explained mainly with phenomena that implicate the electrons excitation trapped in form of F centers and trapping mechanisms or radioactive and non-radioactive recombination. (Author)

  11. Assessment of diagnostic multileaf collimator for cephalometric exposure reduction using optically stimulated luminescent dosemeters

    International Nuclear Information System (INIS)

    Han, Su Chul; Kim, Kum Bae; Jung, Haijo; Ji, YoungHoon; Park, Seungwoo

    2017-01-01

    A diagnostic multileaf collimator (MLC) was developed for diagnostic radiography dose reduction. Optically stimulated luminescent dosemeters (OSLDs) were used to evaluate the efficacy of this device for dental radiography cephalometric exposure reduction. The OSLD dosimetric characteristics for 80 kVp cephalometric exposure were first obtained. The batch homogeneity and reproducibility were 1.67 % and 0.18-1.58, respectively. Good linearity was obtained between the OSLD dose and response, and the angular dependence was within ±4 %. The equivalent organ doses for the left eye, right eye and thyroid were 41.20±6.58, 178.86±1.71 and 171.12±8.78 mSv and 36.80±0.33, 156.63±0.22 and 22.04±0.13 mSv for the open and MLC fields, respectively. The MLC-induced dose reductions for the left and right eyes of in field were 10.67±16.78 and 12.42±8.84 %, respectively, and that of the thyroid gland of out of field was 87±8.82 %, considering combined uncertainty. Therefore, use of diagnostic MLC for dose reduction during dental radiography cephalometric exposure is both feasible and effective. (authors)

  12. GENERALISATION OF RADIATOR DESIGN TECHNIQUES FOR PERSONAL NEUTRON DOSEMETERS BY UNFOLDING METHOD.

    Science.gov (United States)

    Oda, K; Nakayama, T; Umetani, K; Kajihara, M; Yamauchi, T

    2016-09-01

    A novel technique for designing a radiator suitable for personal neutron dosemeter based on plastic track detector was discussed. A multi-layer structure has been proposed in the previous report, where the thicknesses of plural polyethylene (PE) layers and insensitive ones were determined by iterative calculations of double integral. In order to arrange this procedure and make it more systematic, unfolding calculation has been employed to estimate an ideal radiator containing an arbitrary hydrogen concentration. In the second step, realistic materials replaced it with consideration of minimisation of the layer number and commercial availability. A radiator consisting of three layers of PE, Upilex and Kapton sheets was finally designed, for which a deviation in the energy dependence between 0.1 and 20 MeV could be controlled within 18 %. An applicability of fluorescent nuclear track detector element has also been discussed. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. Thermoluminescent dosemeters for determining the energy absorbed during X-ray radiography of the vertebral column

    International Nuclear Information System (INIS)

    Liebl, R.

    1983-01-01

    The dose and absorbed energy during normal diagnostic X-ray of various sections of the vertebral column were determined with LiF-dosemeters in a phantom. The paper describes a method to be used to determine integral doses from the dose measurements. The energy absorbed for one X-ray picture of the vertebral column is between 5 and 30 mJ. Compared to other diagnostical X-rays the quantity of the energy absorbed during X-ray of the vertebral column is rather high and is only reached by X-rays in the pelvic region. The speculations on the rate of incidence of malignent neoplasms on the basis of diagnostical X-ray of the vertebral column reveal a value of 50 per 60 x 10 6 persons. This value is likely to overestimate the risk, seems, however, to be low in comparison to other risks of every day life (traffic accident, mountainering, etc). (orig./HP) [de

  14. Spin glasses

    International Nuclear Information System (INIS)

    Mookerjee, Abhijit

    1976-01-01

    ''Spin glasses'', are entire class of magnetic alloys of moderate dilution, in which the magnetic atoms are far enough apart to be unlike the pure metal, but close enough so that the indirect exchange energy between them (mediated by the s-d interaction between local moments and conduction electrons) dominates all other energies. Characteristic critical phenomena displayed such as freezing of spin orientation at 'Tsub(c)' and spreading of magnetic ordering, are pointed out. Anomalous behaviour, associated with these critical phenomena, as reflected in : (i) Moessbauer spectroscopy giving hyperfine splitting at Tsub(c), (ii) maxima in susceptibility and remanent magnetism, (iii) thermopower maxima and change in slope, (iv) Characteristic cusp in susceptibility and its removal by very small magnetic fields, and (v) conductivity-resistivity measurements, are discussed. Theoretical developments aimed at explaining these phenomena, in particular, the ideas from percolation and localisation theories, and the approach based on the gellations of polymers, are discussed. Finally, a new approach based on renormalisation group in disordered systems is also briefly mentioned. (K.B.)

  15. Effect of the energy dependence of response of neutron personal dosemeters routinely used in the UK on the accuracy of dose estimation

    CERN Document Server

    Tanner, R J; Thomas, D J

    2002-01-01

    A large set of neutron energy distributions have been classified by workplace to provide a guide to the neutron fields to which workers in particular industries are likely to be exposed. These have been combined (folded) with the results of a major programme of neutron personal dosemeter response function measurements, to provide results for the systematic errors that those dosemeters would give in workplaces. Data for neutron doses recorded for UK classified workers have been taken from the CIDI tables, and related to the results from the folding process. It has hence been possible to draw conclusions about the probable systematic errors that result from the use of the currently available neutron personal dosemeters, which have inherent problems associated with their energy dependence of response.

  16. Effect of the energy dependence of response of neutron personal dosemeters routinely used in the UK on the accuracy of dose estimation

    International Nuclear Information System (INIS)

    Tanner, R.J.; Thomas, D.J.; Bartlett, D.T.

    2002-01-01

    A large set of neutron energy distributions have been classified by workplace to provide a guide to the neutron fields to which workers in particular industries are likely to be exposed. These have been combined (folded) with the results of a major programme of neutron personal dosemeter response function measurements, to provide results for the systematic errors that those dosemeters would give in workplaces. Data for neutron doses recorded for UK classified workers have been taken from the CIDI tables, and related to the results from the folding process. It has hence been possible to draw conclusions about the probable systematic errors that result from the use of the currently available neutron personal dosemeters, which have inherent problems associated with their energy dependence of response. (author)

  17. Calibration of PADC-based neutron area dosemeters in the neutron field produced in the treatment room of a medical LINAC

    International Nuclear Information System (INIS)

    Bedogni, R.; Domingo, C.; Esposito, A.; Gentile, A.; García-Fusté, M.J.; San-Pedro, M. de; Tana, L.; D’Errico, F.; Ciolini, R.; Di Fulvio, A.

    2013-01-01

    PADC-based nuclear track detectors have been widely used as convenient ambient dosemeters in many working places. However, due to the large energy dependence of their response in terms of ambient dose equivalent (H ∗ (10)) and to the diversity of workplace fields in terms of energy distribution, the appropriate calibration of these dosemeters is a delicate task. These are among the reasons why ISO has introduced the 12789 Series of Standards, where the simulated workplace neutron fields are introduced and their use to calibrate neutron dosemeters is recommended. This approach was applied in the present work to the UAB PADC-based nuclear track detectors. As a suitable workplace, the treatment room of a 15 MV Varian CLINAC DHX medical accelerator, located in the Ospedale S. Chiara (Pisa), was chosen. Here the neutron spectra in two points of tests (1.5 m and 2 m from the isocenter) were determined with the INFN-LNF Bonner Sphere Spectrometer equipped with Dysprosium activation foils (Dy-BSS), and the values of H ∗ (10) were derived on this basis. The PADC dosemeters were exposed in these points. Their workplace specific H*(10) responses were determined and compared with those previously obtained in different simulated workplace or reference (ISO 8529) neutron fields. - Highlights: ► The neutron field of a medical LINAC was used to calibrate PADC neutron dosemeters. ► The neutron spectra were derived with a Dy-foil based Bonner Sphere Spectrometer. ► Workplace specific calibration factor were derived for the PADC dosemeters. ► These factors were compared with those obtained in reference neutron fields

  18. Operational comparison of TLD albedo dosemeters and etched-track detectors in the PuO2-UO2 mixed oxide fuel fabrication facilities

    International Nuclear Information System (INIS)

    Tsujimura, N.; Takada, C.; Yoshida, T.; Momose, T.

    2005-01-01

    Full text: The authors carried out an operational study that compared the use of TLD albedo dosemeters with etched-track detector in plutonium environments of Japan Nuclear Cycle Development Institute, Tokai Works. A selected group of workers engaged in the fabrication process of MOX (PuO 2 -UO 2 mixed oxide) fuel wore both TLD albedo dosemeters and etched-track detectors over a period from 1991 to 1993. The TLD albedo dosemeter is the Panasonic model UD-809P and the etched-track detector is the NEUTRAK (polyallyl diglycol carbonate + 1mm-t polyethylene radiator) commercially available from Nagase-Landauer Ltd. Both dosemeters were issued and read monthly. It was found that the TL readings were generally proportional to the counted etch-pits, and thus the dose equivalent results obtained from TLD albedo dosemeter agreed with those from etched-track detector within a factor of 1.5. This result indicates that, in the workplaces of the MOX plants, the neutron spectrum remained almost constant in terms of time and space, and the appropriate range of field-specific correction with spectrum variations could be small in albedo dosimetry. In addition, the calibrations of both dosemeters in the workplaces and in a bare and moderated 252 Cf calibration field were performed for quantitative validation for the results from the operational comparison. In the former experiments, locations were selected that were representative of typical neutron measurements according to the prior neutron spectra measurements with the multi-sphere spectrometer. In the latter experiments, the workplace environments were simulated by using a 252 Cf source surrounded with cylindrical steel/PMMA moderators. From both experiments, the relationship between TL readings and counted etch-pits with neutron spectrum variation was determined. As expected, the relationship obtained from the simulated workplace field calibration reproduced that from the operational comparison. (author)

  19. Dosimetric studies of the eye lens using a new dosemeter – Surveys in interventional radiology departments

    International Nuclear Information System (INIS)

    Pirchio, R.; Sánchez, H.; Domazet, W.

    2014-01-01

    During interventional radiology (IR) and cardiology (IC) procedures, medical staff can receive high doses to their eye lenses. The Retrospective Evaluation of Lens Injuries and Dose study organized in Argentina in 2010 found incipient opacity in 50% of IC physicians and 41% of IC technicians/nurses. These results, added to the recommendations of the International Commission on Radiological Protection, which lowered their former occupational equivalent dose limit for the lens, led us to assess the eye lens dose, Hp(3), during interventional procedures. To this end, a new dosemeter was designed and calibrated at the National Atomic Energy Commission of Argentina to evaluate Hp(3). Personal dose equivalent (Hp(10)), and Hp(3) were assessed for 3 months in two IC and IR departments. An Alderson phantom was used to simulate monthly exposures of five occupational staff members. Hp(3) and Hp(10) were obtained monthly for 14 occupational staff members exposed to 121 IR and IC procedures. We concluded that the annual effective dose and Hp(3) were lower than 0.3 and 10 mSv, respectively and the average cumulative Hp(3) for working life was lower than 400 and 200 mSv for physicians and technicians/scrub nurse, respectively. An occupational annual dose constraint of 0.3 mSv was calculated. - Highlights: • An eye lens dosimeters was designed at the Personal Dosimetry Laboratory of CNEA. • A successful dosimetric survey in two interventional departments was done. • The annual effective dose and the annual eye lens dose are lower than the ICRP dose thresholds. • In order to reduce doses actions should be promoted to maximize radiation protection

  20. Practical low dose limits for passive personal dosemeters and the implications for uncertainties close to the limit of detection

    International Nuclear Information System (INIS)

    Gilvin, P. J.; Perks, C. A.

    2011-01-01

    Recent years have seen the increasing use of passive dosemeters that have high sensitivities and, in laboratory conditions, detection limits of <10 μSv. However, in real operational use the detection limits will be markedly higher, because a large fraction of the accrued dose will be due to natural background, and this must be subtracted in order to obtain the desired occupational dose. No matter how well known the natural background is, the measurement uncertainty on doses of a few tens of microsieverts will be large. Individual monitoring services need to recognise this and manage the expectations of their clients by providing sufficient information. (authors)

  1. Obtention of thermoluminescent efficiencies by means of irradiation of TLD-100 dosemeters with proton beams helium and carbon

    International Nuclear Information System (INIS)

    Avila, O.; Rodriguez V, M.; Aviles, P.; Gamboa de Buen, I.; Buenfil, A.E.; Ruiz T, C.; Brandan, M.E.

    2002-01-01

    In this work, the advances of a serial of measurements of relative efficiency thermoluminescent of heavy charged particles (PCP) with respect to gamma radiation for TLD-100, dosemeters of LiF: Mg,Ti manufactured by the Harshaw-Bicron company are reported. The PCP are essentials in the implementation of dosimetry associated with medical applications. The measurements before gamma radiation were carrying out using the Vickrad irradiator of the National Institute of Nuclear Research at dose of 1.663 Gy. The measures which are reported about protons, helium and carbon were realized using the Pelletron accelerator of the Physics Institute of the UNAM. (Author)

  2. Development of quality assurance procedures for thermoluminescent CaSO sub 4 :Dy-teflon skived tape dosemeter

    Energy Technology Data Exchange (ETDEWEB)

    Nagpal, J.S.; Popli, K.L.; Kher, R.K.; Varadharajan, G. (Bhabha Atomic Research Centre, Bombay (India). Div. of Radiological Protection)

    1992-01-01

    CaSO{sub 4}:Dy-Teflon TLD dosemeter material has been manufactured locally in a 0.4 mm thick continuous tape form. Fourteen batches have been examined for physical thickness, density, spectral transmission, diffuse optical density, beta transmission and TL output per unit area for evolving a procedure for quality assurance of the TLD element for large scale production. With the exception of two batches, the TL output per unit area of the tape for a number of batches lies within {+-}7% of that for a standard batch. (author).

  3. Determination of kinetic parameters in Tl dosemeters of LiF: Mg, Cu, P + PTFE developed in the ININ

    International Nuclear Information System (INIS)

    Basurto G, B.S.

    2002-01-01

    The objective of this work, is the one of determining the kinetic parameters of the dosemeter of LiF: Mg, Cu, P + Ptfe; starting from the curves Tl obtained at being irradiated with alpha radiation (α), beta (β) and gamma (γ). As like to compare its sensitivity with each radiation type, considering the sensitivity of the TLD-100 as the unit. In the Chapter 1, the fundamental structure of the matter is described, making emphasis in the different radiation types, and their interaction with this. In the Chapter 2, the units are described but used in the dosimetry of the radiation. In the Chapter 3, the basic concepts of the phenomenon of Tl are described and those are explained characteristic of the deconvolution method to determine the kinetics of the one phenomenon. In the Chapter 4, the methodology is detailed that was used in the elaboration of this thesis work, describing the material Tl that were considered like reference, as well as the sources of ionizing radiation, with those that the dosemeters were irradiated and the equipment in the one that the curves Tl was obtained. Reference is made to the software used to carry out the deconvolution of the curves Tl that were obtained in the one experimental development. In the Chapter 5, the obtained results of this study are presented, showing the tables of homogenization of dosemeters and the reading of the same one; they are observed the curves Tl obtained to different radiation doses (alpha, beta and gamma), the intensity Tl in function of the dose. Also they are tabulated, the obtained results in the kinetic parameters of the three different study materials (TLD-100H, USA; TLD-100, USA and LiF: Mg, Cu, P + Ptfe developed in the l.N.l.N). They are analyzed shortly for each material Tl their sensitivity to the ionizing radiation as well as their kinetic parameters. The obtained results showed that the Tl dosemeters of LiF: Mg,Cu,P + Ptfe, they presented a bigger sensitivity that the TLD-100 when being

  4. Responses of commercially available neutron electronic personal dosemeters in neutron fields simulating workplaces at MOX fuel fabrication facilities

    International Nuclear Information System (INIS)

    Tsujimura, N.; Yoshida, T.; Takada, C.

    2011-01-01

    The authors investigated the performance of three commercially available electronic personal dosemeters (EPDs) in evaluating neutron dose equivalents and discussed their suitability to work environments in MOX fuel fabrication facilities. The EPDs selected for this study were NRY21 (Fuji Electric Systems), PDM-313 (Aloka) and DMC 2000 GN (MGP Instruments). All tests were conducted in moderated 252 Cf neutron fields with neutron spectral and dosimetric characteristics similar to those found in MOX fuel facilities. The test results revealed trends and the magnitude of response variations in relation to neutron spectral changes expected in work environments.

  5. Design and validation of a single sphere multi-detector neutron spectrometer based on LiF: Mg,Cu,P thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Gomez-Ros, Jose Maria; Bedogni, Roberto; Moraleda, Montserrat; Romero, Ana; Delgado, Antonio; Esposito, Adolfo

    2010-01-01

    This communication describes a new neutron spectrometer consisting of pairs of 7 Li and 6 Li based thermoluminescent dosemeters (MCP-6, MCP-7) located at selected positions within a single moderating polyethylene sphere. The spatial arrangement of the dosemeters has been designed using the MCNPX Monte Carlo code to calculate the response matrix in order to obtain a nearly isotropic response for neutrons in the energy range up to 20 MeV. A partial validation of the calculated response matrix has been performed with the calibrated 241 Am-Be neutron source at the INFN-LNF Laboratory, using the shadow cone technique.

  6. Optical fibre dosemeter systems for clinical applications based on radioluminescence and optically stimulated luminescence from Al2O3:C

    DEFF Research Database (Denmark)

    Marckmann, C.J.; Andersen, C.E.; Aznar, M.C.

    2006-01-01

    Optical fibre dosemeter systems based on radioluminescence and optically stimulated luminescence (OSL) from carbon-doped aluminium oxide (Al2O3:C) crystals were developed for in vivo real-time dose rate and absorbed dose measurements in radiotherapy and mammography. A technique was also developed...... for making ultra-small dosemeter probes that can easily be placed inside patients in radiation treatment. These probes have shown excellent properties in both head and neck intensity-modulated radiation therapy treatment and in mammography. The dose-response of the OSL signal for the new optical fibre...

  7. lead glass brick

    CERN Multimedia

    When you look through the glass at a picture behind, the picture appears raised up because light is slowed down in the dense glass. It is this density (4.06 gcm-3) that makes lead glass attractive to physicists. The refractive index of the glass is 1.708 at 400nm (violet light), meaning that light travels in the glass at about 58% its normal speed. At CERN, the OPAL detector uses some 12000 blocks of glass like this to measure particle energies.

  8. Requirements of the Physikalisch-Technische Bundesanstalt (PTB) for therapy dosemeters with ionization chambers submitted for calibration and approval

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    Therapy dosemeters are subject to calibration as from January 1, 1983 according to section 3 of the second ordinance concerning the obligation to calibrate measuring instruments (in the version of the ordinance concerning the amendment of the second and third ordinance about the obligation to calibrate measuring instruments of December 21, 1979, Federal Gazette I p 2347). Section 4 subsection 2 of this ordinance determines a transitional period until December 31, 1985. In this transitional period those therapy dosemeters may be used without calibration which were already in use on January 1, 1983. The requirements of the PTB correspond to the established rules of technology. They specify and complete the provisions of the standardization regulations and establish terms and conditions of the test. They passed the general assembly of the Physikalisch-Technische Bundesanstalt concerning calibration and measurement of 1982. The requirements of the PTB stipulate the admissible limits for effects of numerous influencing factors and other properties of the equipment and tolerances of calibration and handling. (orig.) [de

  9. Influence of the phantom shape (slab, cylinder or Alderson) on the performance of an Hp(3) eye dosemeter

    International Nuclear Information System (INIS)

    Behrens, R.; Hupe, O.

    2016-01-01

    In the past, the operational quantity H p (3) was defined for calibration purposes in a slab phantom. Recently, an additional phantom in the form of a cylinder has been suggested for eye lens dosimetry, as a cylinder much better approximates the shape of a human head. Therefore, this work investigates which of the two phantoms, slab or cylinder, is more suitable for calibrations and type tests of eye dosemeters. For that purpose, a typical H p (3) eye dosemeter was irradiated on a slab, a cylinder and on a human-like Alderson phantom. It turned out that the response on the three phantoms is nearly equal for angles of radiation incidence up to 45 deg. and deviates only at larger angles of incidence. Thus, calibrations (usually performed at 0 deg. radiation incidence) are practically equivalent on both the slab and the cylinder phantoms. However, type tests (up to 75 deg. or even 90 deg. radiation incidence) should be carried out on a cylinder phantom, as also for large angles of incidence the response on the cylinder and the Alderson phantoms is rather similar, whereas the response on the slab significantly deviates from the one on the Alderson phantom. (authors)

  10. Analysis of QUADOS problem on TLD-ALBEDO personal dosemeter responses using discrete ordinates and Monte Carlo methods

    International Nuclear Information System (INIS)

    Kodeli, I.; Tanner, R.

    2005-01-01

    In the scope of QUADOS, a Concerted Action of the European Commission, eight calculational problems were prepared in order to evaluate the use of computational codes for dosimetry in radiation protection and medical physics, and to disseminate 'good practice' throughout the radiation dosimetry community. This paper focuses on the analysis of the P4 problem on the 'TLD-albedo dosemeter: neutron and/or photon response of a four-element TL-dosemeter mounted on a standard ISO slab phantom'. Altogether 17 solutions were received from the participants, 14 of those transported neutrons and 15 photons. Most participants (16 out of 17) used Monte Carlo methods. These calculations are time-consuming, requiring several days of CPU time to perform the whole set of calculations and achieve good statistical precision. The possibility of using deterministic discrete ordinates codes as an alternative to Monte Carlo was therefore investigated and is presented here. In particular the capacity of the adjoint mode calculations is shown. (authors)

  11. Use of TL dosemeters for measuring doses of external gamma radiation in the vicinity of the Dukovany NPP

    International Nuclear Information System (INIS)

    Ohera, M.; Fiala, E.; Valasek, J.

    1992-01-01

    The results of measurement of the photon dose equivalent from external gamma radiation in the surroundings of the Dukovany nuclear power plant are given for 20 sites in southern Moravia over the 1984-1990 period, i.e., one year before starting up the plant and 6 years of its operation. CaSO 4 :Dy TL dosemeters were used, applying filtration with 0.5 mm Pb and 0.2 mm Pb + 0.6 mm Sn. Since 1989, the towns along the borders with Austria (Znojmo, Vranov, Mikulov) have been included, along with the Brno, Trebic, Zakrany, Ivancice and Jaromerice sites, into the national monitoring TL dosimetric network. The elevated doses at some sites come from the bedrock and are not caused by the operation of the plant. The effect of the Chernobyl accident on the dosemeter response is also evaluated. Comparison of the data prior to the Dukovany plant start-up (1984) and during the operation (1985-1990) give evidence that the operation of the power plant did not bring about any increase in the values monitored. (Z.S.). 3 tabs., 8 figs., 9 refs

  12. Glass and nuclear wastes

    International Nuclear Information System (INIS)

    Sombret, C.

    1982-10-01

    Glass shows interesting technical and economical properties for long term storage of solidified radioactive wastes by vitrification or embedding. Glass composition, vitrification processes, stability under irradiation, thermal stability and aqueous corrosion are studied [fr

  13. Microstructuring of glasses

    CERN Document Server

    Hülsenberg, Dagmar; Bismarck, Alexander

    2008-01-01

    As microstructured glass becomes increasingly important for microsystems technology, the main application fields include micro-fluidic systems, micro-analysis systems, sensors, micro-actuators and implants. And, because glass has quite distinct properties from silicon, PMMA and metals, applications exist where only glass devices meet the requirements. The main advantages of glass derive from its amorphous nature, the precondition for its - theoretically - direction-independent geometric structurability. Microstructuring of Glasses deals with the amorphous state, various glass compositions and their properties, the interactions between glasses and the electromagnetic waves used to modify it. Also treated in detail are methods for influencing the geometrical microstructure of glasses by mechanical, chemical, thermal, optical, and electrical treatment, and the methods and equipment required to produce actual microdevices.

  14. Measurement of optical glasses

    International Nuclear Information System (INIS)

    Nicolau-Rebigan, S.

    1978-11-01

    The possibilities of measurement of the optical glasses parameters needed in building optical devices especially in lasers devices are presented. In the first chapter the general features of the main optical glasses as well as the modalities of obtaining them are given. Chapter two defines the optical glass parameters, and the third chapter describes the measuring methods of the optical glass parameters. Finally, the conclusions which point out the utilization of this paper are presented. (author)

  15. Mechanically reinforced glass beams

    DEFF Research Database (Denmark)

    Nielsen, Jens Henrik; Olesen, John Forbes

    2007-01-01

    laminated float glass beam is constructed and tested in four-point bending. The beam consist of 4 layers of glass laminated together with a slack steel band glued onto the bottom face of the beam. The glass parts of the tested beams are \\SI{1700}{mm} long and \\SI{100}{mm} high, and the total width of one...

  16. The MCNP-4C2 design of a two element photon/electron dosemeter that uses magnesium/copper/phosphorus doped lithium fluoride.

    Science.gov (United States)

    Eakins, J S; Bartlett, D T; Hager, L G; Molinos-Solsona, C; Tanner, R J

    2008-01-01

    The Health Protection Agency is changing from using detectors made from 7LiF:Mg,Ti in its photon/electron personal dosemeters, to 7LiF:Mg,Cu,P. Specifically, the Harshaw TLD-700H card is to be adopted. As a consequence of this change, the dosemeter holder is also being modified not only to accommodate the shape of the new card, but also to optimize the photon and electron response characteristics of the device. This redesign process was achieved using MCNP-4C2 and the kerma approximation, electron range/energy tables with additional electron transport calculations, and experimental validation, with different potential filters compared; the optimum filter studied was a polytetrafluoroethylene disc of diameter 18 mm and thickness 4.3 mm. Calculated relative response characteristics at different angles of incidence and energies between 16 and 6174 keV are presented for this new dosemeter configuration and compared with measured type-test results. A new estimate for the energy-dependent relative light conversion efficiency appropriate to the 7LiF:Mg,Cu,P was also derived for determining the correct dosemeter response.

  17. Evaluation of influence by room-scattered neutrons and source-to-phantom geometrical effect for calibration of personal neutron dosemeters

    International Nuclear Information System (INIS)

    Yoshida, Tadayoshi; Tsujimura, Norio

    2005-01-01

    Correction for the influence of room-scattered neutrons in irradiation rooms is essential in the case of calibrating neutron dosemeters. The ISO8529-2 recommends some correction method such as the shadow-cone method and the generalized-fit method for the calibration of neutron ambient dose equivalent (rate) meters. However, the ISO standard does not describe the correction methods for personal neutron dosemeters in detail. The authors investigated the variation of responses of neutron detectors mounted on phantom as a function of source-to-phantom distance, and discussed the applicability of the shadow-cone method and generalized-fit method for calibrating personal neutron dosemeters. The measurements were carried out using 3 He and hydrogen-filled proportional counters as surrogates of albedo and recoil-proton type dosemeters, respectively, at different distances ranging from 30 cm to 400 cm. As a result, it was clarified that both correction methods are applicable for recoil-proton type detectors over any distance. Contrarily, for albedo-type detectors, the variation of response does not follow the curve predicted from the generalized fit method at distances smaller than 70 cm. This result strongly suggests that the correction for source-to-phantom geometry effect should be made for calibrating albedo-type detectors at smaller distances. (author)

  18. About the measurements systems with pen and thermoluminescent dosemeters; Sobre los sistemas de medicion con dosimetros de pluma y los termoluminiscentes

    Energy Technology Data Exchange (ETDEWEB)

    Cortes I, M.E.; Ramirez G, F.P. [Instituto Mexicano del Petroleo, Eje Central Lazaro Cardenas 152. 07730 Mexico D.F. (Mexico)

    1998-12-31

    In this work it is presented dosimetric data obtained with pen and thermoluminescent dosemeters, which are used by the Occupational Exposure Personnel (OEP) of the Mexican Petroleum Institute (IMP)(1). It was marked several great characteristics as for example, the differences among units which use one and another dosemeter type. Likewise, it is given to know diverse problems that were had in the IMP at relating the data obtained with these dosemeters (which utilizes OEP) and the ICRP 60 recommendations 1990. One of the most important difficulties is to satisfy the recommended limits by ICRP, particularly those that are referring to the units and their complex calculations. With respect to the unities, the ICRP makes reference at the concepts `dose equivalent` and `effective dose` with the sievert unit, that the General Regulations for Radiological Safety associates with `dose equivalent` and `effective dose equivalent`. It was illustrated the type of dosimetric statistics which are obtained with the TLD lectures and a OEP pen dosemeter during 1997. (Author)

  19. Fluoride glass fiber optics

    CERN Document Server

    Aggarwal, Ishwar D

    1991-01-01

    Fluoride Glass Fiber Optics reviews the fundamental aspects of fluoride glasses. This book is divided into nine chapters. Chapter 1 discusses the wide range of fluoride glasses with an emphasis on fluorozirconate-based compositions. The structure of simple fluoride systems, such as BaF2 binary glass is elaborated in Chapter 2. The third chapter covers the intrinsic transparency of fluoride glasses from the UV to the IR, with particular emphasis on the multiphonon edge and electronic edge. The next three chapters are devoted to ultra-low loss optical fibers, reviewing methods for purifying and

  20. Multiple Glass Ceilings

    OpenAIRE

    Russo, Giovanni; Hassink, Wolter

    2011-01-01

    Both vertical (between job levels) and horizontal (within job levels) mobility can be sources of wage growth. We find that the glass ceiling operates at both margins. The unexplained part of the wage gap grows across job levels (glass ceiling at the vertical margin) and across the deciles of the intra-job-level wage distribution (glass ceiling at the horizontal margin). This implies that women face many glass ceilings, one for each job level above the second, and that the glass ceiling is a p...

  1. Homogeneity of Inorganic Glasses

    DEFF Research Database (Denmark)

    Jensen, Martin; Zhang, L.; Keding, Ralf

    2011-01-01

    Homogeneity of glasses is a key factor determining their physical and chemical properties and overall quality. However, quantification of the homogeneity of a variety of glasses is still a challenge for glass scientists and technologists. Here, we show a simple approach by which the homogeneity...... of different glass products can be quantified and ranked. This approach is based on determination of both the optical intensity and dimension of the striations in glasses. These two characteristic values areobtained using the image processing method established recently. The logarithmic ratio between...

  2. Test of ring, eye lens and whole body dosemeters for the dose quantity Hp(3) to be used in interventional radiology

    Science.gov (United States)

    Szumska, A.; Budzanowski, M.; Kopeć, R.

    2017-11-01

    In its statement on tissue reactions approved on 21st April 2011, the International Commission on Radiological Protection (ICRP, 2012) reviewed its recommendation concerning the equivalent dose limit for the eye lens and reduced the dose limits for occupationally exposed persons to 20 mSv in a year, averaged over defined periods of 5 years, with no single year exceeding 50 mSv. This limit was approved and written down in the new EURATOM (European Atomic Energy Community) directive 2013/59 and in the IAEA (International Atomic Energy Agency) BSS (Basic Safety Standard) of July 2014. For that reason, the necessity to monitor the eye lens may become more important than it was before. However, specially dedicated dosemeters for the dose quantity Hp(3) are using very rarely. Commonly use are only whole body personal dosemeters for the personal dose equivalent quantities Hp(10) worn on the trunk and ring dosemeters worn on finger to measure the quantity Hp(0.07). Therefore, in this work it was investigated whether dosemeters from routine use calibrated in terms of Hp(10) and Hp(0.07) and worn on thyroid collar and protective apron could deliver similar results like dedicated eye lens dosemeter worn close to the eyes. The results show that the best method if dedicated eye lens dosimeters is not used is to measure doses in terms of Hp(0.07) on the thyroid collar (Pearson product, r=0.85). Obtained results shows also importance of proper localization of eye lens dosimeter (close to the eye, from side of the X-ray source).

  3. Leaching of glass

    International Nuclear Information System (INIS)

    Hench, L.L.

    1977-01-01

    Understanding surface compositional profiles of glasses over a range of 0-2000 A with a variety of analytical instruments shows that five general types of glass surfaces exist. The surface character of a glass article depends upon bulk composition and environmental history during which surface dealkalization, film formation, and network dissolution can occur. Environmental-surface interactions generally result in complex compositional profiles of all the constituents in a glass. Durable glasses almost always develop a stable surface film which has a higher concentration of network formers than the bulk composition. Compositional effects that are used to improve glass durability usually improve the stability of the surface films. Durability tests or service conditions that lead to film destruction are especially severe for the most silicate glasses. 43 references

  4. Use of active dosemeters as a optimization tool in hemodynamics; Uso de dosimetros ativos como ferramenta de otimizacao em hemodinamica

    Energy Technology Data Exchange (ETDEWEB)

    Nunes, Rafael; Pereira, Dirceu D. [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil). Inst. de Fisica; Canevaro, Lucia V. [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Rodrigues, Barbara B.D. [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil); Ferreira, Esmeralci [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil). Faculdade de Medicina. Servico de Hemodinamica

    2016-07-01

    Interventional cardiology procedures are, in general, associated with high doses in patients and professionals. The objective of this study is to measure the radiation levels received by professionals .The professional dosimetry was performed in a department of Hemodynamics of University Hospital in Rio de Janeiro. were followed 331 coronary angiography (CA) and 26 percutaneous transluminal coronary angioplasty (PTCA) procedures. For this, were used active dosemeters to measure the radiation levels at the chest of interventional professionals. The results show that average personal equivalent dose of doctors, per procedure was 100 e 154 μSv. On average, nursing technicians and radiologist receive 12 and 10% of doses of physicians, respectively, during CA procedures. From the results, it appears that the doses of hemodynamics exceed the annual dose limit of the standards. The use of lead shielding is presented as an effective action to reduce doses in these workers. (author)

  5. A Modification of Gamma Surveymeter Dosemeter 3007A for Monitoring Use Ethernet by PLC T100MD Series

    International Nuclear Information System (INIS)

    Ikhsan Shobari; Subchan, M.; Syahrudin Yusuf; Sutomo Budihardjo

    2010-01-01

    It has been modified a gamma surveymeter Dosemeter 3007A. The Surveymeter represents analogous surveymeter, so that an interface for data acquisition is required. Acquisition system from surveymeter is added to the voltage amplifier module from 0 - 200 mV to 0 - 5 V. This voltage value will represent of doses 0 - 5 mR/hour. Hereinafter the analogous signal 0 - 5 V as signal of input to peripheral of PLC T100MD series. Data in the form of processed analogous signal presented at local display of PLC. For long distance monitoring, data have been sent to a computer from PLC by ethernet. After this modification, the surveymeter can be used to monitor from long distance. By using Internet Service Provider, monitoring can be done at any time and any where as long as network internet is available. (author)

  6. The ferrous ammonium sulfate solid system, as dosemeter for processes at low temperatures and high doses of gamma radiation

    International Nuclear Information System (INIS)

    Juarez C, J.M.; Ramos B, S.; Negron M, A.

    2005-01-01

    This paper presents the results obtained from a study of the radiation induced oxidation of crystalline ferrous ammonium sulfate with gamma rays at 295 K, 263 K and 77 K and dose from 0 to 300 kGy. The radiation induced decomposition of ferrous ammonium sulfate has been studied by the dissolution of the irradiated salt in 0,8 N sulfuric acid. The main product is Fe 3+ and molar concentration of ferric ion was determined spectrophotometrically in the UV region at 304 nm. The optical density values showed a linear dependence with dose, indicating that the data obtained might be used to create a calibrating curve. Color in irradiated salt changes from blue to green, yellow and orange according to the absorbed dose. The accuracy and the reproducibility of the system were tested. In addition, some other characteristics make possible the use of this system as a dosimeter, similar to Fricke chemical dosemeter, at low temperatures and high dose. (Author)

  7. 3D dosimetry study of 188Re liquid balloon for intravascular brachytherapy using BANG polymer gel dosemeters

    International Nuclear Information System (INIS)

    Wuu, S.; Schiff, P.B.; Maryanski, M.; Liu, T.; Borzillary, S.; Weinberger, J.

    2002-01-01

    It has been suggested that the combination of intravascular brachytherapy and coronary stent implantation may result in further reduction of restenosis after percutaneous balloon angioplasty. The use of an angioplasty balloon filled with a P 188 Re liquid beta source for intravascular brachytherapy provides the advantage of accurate source positioning and uniform dose distribution to the coronary vessel wall. The effect of source edge and stent on the dose distribution of the target tissue may be clinically important. In BANG gels, the absorbed radiation produces free-radical chain polymerisation of acrylic monomers that are initially dissolved in the gel. The number of polymer particles is proportional to the absorbed dose. In this study, 3D dose distributions are presented for 188 Re balloons, with and without stents, using a prototype He-Ne laser CT scanner and the proprietary BANG polymer gel dosemeters. (author)

  8. Application of workplace correction factors to dosemeter results for the assessment of personal doses at nuclear facilities

    International Nuclear Information System (INIS)

    Lindborg, L.; Bolognese-Milsztajn, T.; Boschung, M.; Coeck, M.; Curzio, G.; D'Errico, F.; Fiechtner, A.; Hallfarth, D.; Lievens, B.; Lillhoek, J. E.; Loevefors-Daun, A.; Lacoste, V.; Luszik-Bhadra, M.; Reginatto, M.; Schuhmacher, H.; Tanner, R.; Vanhavere, F.

    2007-01-01

    Ratios of H p (10) and H*(10) were determined with reference instruments in a number of workplace fields within the nuclear industry and used to derive workplace-specific correction factors. When commercial survey meter results together with these factors were applied to the results of the locally used personal dosemeters their results improved and became within 0.7 and 1.7 of the reference values or better depending on the response of the survey meter. A similar result was obtained when a correction was determined with a prototype reference instrument for H p (10) after adjustment of its response. Commercially available survey instruments both for photon and neutron H*(10) measurements agreed with the reference instruments in most cases to within 0.5-1.5. Those conclusions are derived from results reported within the EC supported EVIDOS contract. (authors)

  9. Dosimetric evaluation of lithium carbonate (Li2CO3) as a dosemeter for gamma-radiation dose measurements.

    Science.gov (United States)

    Popoca, R; Ureña-Núñez, F

    2009-06-01

    This work reports the possibility of using lithium carbonate as a dosimetric material for gamma-radiation measurements. Carboxi-radical ions, CO(2)(-) and CO(3)(-), arise from the gamma irradiation of Li(2)CO(3), and these radical ions can be quantified by electron paramagnetic resonance (EPR) spectrometry. The EPR-signal response of gamma-irradiated lithium carbonate has been investigated to determine some dosimetric characteristics such as: peak-to-peak signal intensity versus gamma dose received, zero-dose response, signal fading, signal repeatability, batch homogeneity, dose rate effect and stability at different environmental conditions. Using the conventional peak-to-peak method of stable ion radicals, it is concluded that lithium carbonate could be used as a gamma dosemeter in the range of 3-100 Gy.

  10. TL response of LiF: Mg, Cu, P dosemeters in function of the photon energy; Respuesta TL de dosimetros de LiF: Mg, Cu, P en funcion de la energia del foton

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, P.R. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Azorin, J. [UAM-I, 09340 Mexico D.F. (Mexico); Furetta, C. [Universita degli Studi di Roma ' La Sapienza' , Piazzale Aldo Moro 2, 00185 Roma (Italy)

    2005-07-01

    In this work the obtained results of studying the response of dosemeters of LiF: Mg, Cu, P + Ptfe, developed in the ININ, commercial dosemeters GR200A (LiF: Mg, Cu, P) of chinese manufacture and TLD-100 (LiF: Mg, Ti) US are presented, when irradiating them with X rays 16, 24, 34.5, 42, 100 and 145 keV of effective energy, with gamma rays of 662 keV ({sup 137} Cs) and 1252 keV ({sup 60} Co). The results are presented in function of the sensitivity that the dosemeters showed normalized to gamma radiation of {sup 60} Co. It was appreciated that the dosemeters more equivalent to the tissue, they were those of LiF: Mg, Cu, P + Ptfe, while the less equivalent ones were the TLD-100. (Author)

  11. Development of an algorithm for X-ray exposures using the Panasonic UD-802A thermoluminescent dosemeter

    International Nuclear Information System (INIS)

    McKittrick, Leo; Currivan, Lorraine; Pollard, David; Nicholls, Colyn; Romero, A.M.; Palethorpe, Jeffrey

    2008-01-01

    Full text: As part of its continuous quality improvement the Dosimetry Service of the Radiological Protection Institute of Ireland (RPII) in conjunction with Panasonic Industrial Europe (UK) has investigated further the use of the standard Panasonic algorithm for X-ray exposures using the Panasonic UD-802A TL dosemeter. Originally developed to satisfy the obsolete standard ANSI 13.11-1983, the standard Panasonic dose algorithm has undergone several revisions such as HPS N13.11-2001. This paper presents a dose algorithm that can be used to correct the dose response at low energies such as X-ray radiation using a four element TL dosemeter due to the behaviour of two different independent phosphors. A series of irradiations with a range of energies using N-20 up to Co-60 were carried out with our particular interest being in responses to X-ray irradiations. Irradiations were performed at: RRPPS, University Hospital Birmingham NHS Foundation Trust, U.K.; HPA, U.K. and CIEMAT, Madrid, Spain. Different irradiation conditions were employed which included: X-ray from narrow and wide spectra as described by ISO 4037-1 (1996), and ISO water slab phantom and PMMA slab phantom respectively. Using the UD-802A TLD and UD-854AT hanger combination, the response data from the series of irradiations was utilised to validate and if necessary, modify the photon/beta branches of the algorithm to: 1. Best estimate Hp(10) and Hp(0.07); 2. Provide information on irradiation energies; 3. Verification by performance tests. This work further advances the algorithm developed at CIEMAT whereby a best-fit, polynomial trend is used with the dose response variations between the independent phosphors. (author)

  12. Converting a major dosimetry service from film to optically stimulated luminescence dosemeters including revision of the 'back-office' software

    International Nuclear Information System (INIS)

    Perks, Christopher A.; Faugoin, Stephane; Serise, Bertrand; Prugnaud, Brice; Million, Marc

    2008-01-01

    Full text: In our offices at Fontenay-aux-Roses we provide personal dosimetry for over 100,000 participants. During 2005/6 we transformed our operations from film dosemeters to those using Optically Stimulated Luminescence (InLight (Trade Mark)). The opportunity was taken to fully overhaul our operational procedures and we are currently completely reworking our 'back-office' software support. The change from film to InLight dosimetry has involved: 1) The installation of new readers at our offices in Fontenay-aux Roses; 2) The installation of a physical badge archiving system; 3) Complete revision of the operational flow to optimise the benefits of the new service; 4) Maintenance of our approval to operate a personal dosimetry service in France; 5) Considerable liaison between our office in Fontenay-aux-Roses and our Glenwood, USA, parent company to enable complete integration of the processes; and 6) Maintaining the service throughout the changeover and keeping client satisfaction high. Having changed the physical environment we are now completely renewing the back office software and systems in support of the dosimetry service. This ranges in scope from entering new clients, client support, all aspects of the dosimetry operations and chain of custody of the dosemeters and participants records and reports. This system is being rolled out in sections and it is envisaged that it will be fully implemented at the start of 2008. A key feature is that continuing improvement and the possibility of future developments of our services is in-built into the philosophy of the new back-office system. The nature of the new system, its benefits to our own operations and, in particular, clients will be discussed. (author)

  13. Use of a robotic manipulator in the simulation of the automation of a calibration process of dosemeters; Uso de un manipulador robotico en la simulacion de la automatizacion de un proceso de calibracion de dosimetros

    Energy Technology Data Exchange (ETDEWEB)

    Benitez R, J S; Najera H, M C [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2002-07-01

    The development of a system based in a manipulative robot which simulates the operative sequence in a calibration process of dosemeters is presented. In this process it is performed the monitoring of the dosemeter positions and the calibrator by mean of an arm of articulated robot which develops the movement sequences and the taking a decision based on the information coming from the external sensors. (Author)

  14. Fractography of glass

    CERN Document Server

    Tressler, Richard

    1994-01-01

    As the first major reference on glass fractography, contributors to this volume offer a comprehensive account of the fracture of glass as well as various fracture surface topography Contributors discuss optical fibers, glass containers, and flatglass fractography In addition, papers explore fracture origins; the growth of the original flaws of defects; and macroscopic fracture patterns from which fracture patterns evolve This volume is complete with photographs and schematics

  15. Diamond turning of glass

    Energy Technology Data Exchange (ETDEWEB)

    Blackley, W.S.; Scattergood, R.O.

    1988-12-01

    A new research initiative will be undertaken to investigate the critical cutting depth concepts for single point diamond turning of brittle, amorphous materials. Inorganic glasses and a brittle, thermoset polymer (organic glass) are the principal candidate materials. Interrupted cutting tests similar to those done in earlier research are Ge and Si crystals will be made to obtain critical depth values as a function of machining parameters. The results will provide systematic data with which to assess machining performance on glasses and amorphous materials

  16. Glass to contain wastes

    International Nuclear Information System (INIS)

    Moncouyoux, M.; Jacquet-Francillon, M.

    1994-01-01

    Here are the tables and figures presented during the conference on the glass to confine high level radioactive wastes: definition, fabrication, storage and disposal. The composition of glasses are detailed, their properties and the vitrification proceeding. The behaviour of these glasses in front of water, irradiation and heat are shown. The characteristics of parcels are given according to the radiation protection rule, ALARA principle, the concept of multi-barriers and the geological stability

  17. Glass microspheres for brachytherapy

    International Nuclear Information System (INIS)

    Prado, Miguel O.; Prastalo, Simon; Blaumann, Herman; Longhino, Juan M.; Repetto Llamazares, A.H.V.

    2007-01-01

    We developed the capacity to produce glass microspheres containing in their structure one or more radioactive isotopes useful for brachytherapy. We studied the various facts related with their production: (Rare earth) alumino silicate glass making, glass characterization, microspheres production, nuclear activation through (n,γ) nuclear reactions, mechanical characterization before and after irradiation. Corrosion tests in simulated human plasma and mechanical properties characterization were done before and after irradiation. (author) [es

  18. Effective dose assessment in the maxillofacial region using thermoluminescent (TLD) and metal oxide semiconductor field-effect transistor (MOSFET) dosemeters: a comparative study.

    Science.gov (United States)

    Koivisto, J; Schulze, D; Wolff, J; Rottke, D

    2014-01-01

    The objective of this study was to compare the performance of metal oxide semiconductor field-effect transistor (MOSFET) technology dosemeters with thermoluminescent dosemeters (TLDs) (TLD 100; Thermo Fisher Scientific, Waltham, MA) in the maxillofacial area. Organ and effective dose measurements were performed using 40 TLD and 20 MOSFET dosemeters that were alternately placed in 20 different locations in 1 anthropomorphic RANDO(®) head phantom (the Phantom Laboratory, Salem, NY). The phantom was exposed to four different CBCT default maxillofacial protocols using small (4 × 5 cm) to full face (20 × 17 cm) fields of view (FOVs). The TLD effective doses ranged between 7.0 and 158.0 µSv and the MOSFET doses between 6.1 and 175.0 µSv. The MOSFET and TLD effective doses acquired using four different (FOV) protocols were as follows: face maxillofacial (FOV 20 × 17 cm) (MOSFET, 83.4 µSv; TLD, 87.6 µSv; -5%); teeth, upper jaw (FOV, 8.5 × 5.0 cm) (MOSFET, 6.1 µSv; TLD, 7.0 µSv; -14%); tooth, mandible and left molar (FOV, 4 × 5 cm) (MOSFET, 10.3 µSv; TLD, 12.3 µSv; -16%) and teeth, both jaws (FOV, 10 × 10 cm) (MOSFET, 175 µSv; TLD, 158 µSv; +11%). The largest variation in organ and effective dose was recorded in the small FOV protocols. Taking into account the uncertainties of both measurement methods and the results of the statistical analysis, the effective doses acquired using MOSFET dosemeters were found to be in good agreement with those obtained using TLD dosemeters. The MOSFET dosemeters constitute a feasible alternative for TLDs for the effective dose assessment of CBCT devices in the maxillofacial region.

  19. Silicate glasses. Chapter 1

    International Nuclear Information System (INIS)

    Lutze, W.

    1988-01-01

    This chapter is a survey of world-wide research and development efforts in nuclear waste glasses and its production technology. The principal glasses considered are silicate glasses which contain boron, i.e. borosilicate glass. A historical overview of waste form development programs in nine countries is followed by a summary of the design criteria for borosilicate glass compositions glass compositions. In the sections on glass properties the waste form is characterized in terms of potential alterations under the influence of heat, thermal gradients, radiation, aqueous solutions and combinations thereof. The topics are phase transformations, mechanical properties, radiation effects and chemical durability. The results from studies of volcanic glasses, as natural analogues for borosilicate nuclear waste glasses in order to verify predictions obtained from short-term tests in the laboratory, have been compiled in a special section on natural analogues. A special section on advanced vitrification techniques summarizes the various actual and potential processing schemes and describes the facilities. The literature has been considered until 1985. (author). 430 refs.; 68 figs.; 29 tabs

  20. Glass and vitrification

    International Nuclear Information System (INIS)

    Barton, J.L.; Vacher, R.; Moncouyoux, J.P.; Vernaz, E.

    1997-01-01

    Most glasses used as materials are oxides glasses that are produced by a quick quench of a liquid. Glasses are characterized by the absence of periodicity in the atomic arrangements, they do not have symmetries and do not present order over a long distance. This series of 4 short articles present: 1) the properties of glass and its industrial story, 2) the glass structure, 3) a forty years long story of glass as dies used to confine wastes and 4) the methodology used to study the behaviour of glass over very long periods of time. This methodology is based on 5 steps: 1) define and specify the material to study (the prediction of long term alteration of a material is nonsense unless you know well its initial properties), 2) identify all the alteration processes that are likely to happen, determine their kinetics and the influence of environmental parameters, 3) develop mathematical models in order to simulate long-term behaviour of glasses, 4) determine the release rates of the radionuclides confined in the glass, and 5) validate data and models, it is not possible to expect a complete validation of a model that will be extrapolated over tens of thousands of years, nevertheless some ways of validation can lead to a satisfactory level of confidence taking into account reasonable uncertainties. (A.C.)

  1. Characterization of glass and glass ceramic nuclear waste forms

    International Nuclear Information System (INIS)

    Lutze, W.; Borchardt, J.; De, A.K.

    1979-01-01

    Characteristics of solidified nuclear waste forms, glass and glass ceramic compositions and the properties (composition, thermal stability, crystallization, phase behavior, chemical stability, mechanical stability, and radiation effects) of glasses and glass ceramics are discussed. The preparation of glass ceramics may be an optional step for proposed vitrification plants if tailored glasses are used. Glass ceramics exhibit some improved properties with respect to glasses. The overall leach resistance is similar to that of glasses. An increased leach resistance may become effective for single radionuclides being hosted in highly insoluble crystal phases mainly when higher melting temperatures are applicable in order to get more leach resistant residual glass phases. The development of glass ceramic is going on. The technological feasibility is still to be demonstrated. The potential gain of stability when using glass ceramics qualifies the material as an alternative nuclear waste form

  2. Relaxations in spin glasses: Similarities and differences from ordinary glasses

    International Nuclear Information System (INIS)

    Ngai, K.L.; Rajagopal, A.K.; Huang, C.Y.

    1984-01-01

    Relaxation phenomena have become a major concern in the physics of spin glasses. There are certain resemblances of these relaxation properties to those of ordinary glasses. In this work, we compare the relaxation properties of spin glasses near the freezing temperature with those of glasses near the glass transition temperature. There are similarities between the two types of glasses. Moreover, the relaxation properties of many glasses and spin glasses are in conformity with two coupled ''universality'' relations predicted by a recent model of relaxations in condensed matter

  3. Evaluation of Structural Cellular Glass

    Science.gov (United States)

    Adams, M. A.; Zwissler, J. G.

    1984-01-01

    Preliminary design information presented. First report discusses state of structural-cellular-glass programs as of June 1979. Second report gives further details of program to develop improved cellular glasses and to characterize properties of glasses and commercially available materials.

  4. The experience from operation of electronic personal dosimetry system at Dukovany, Temelin and Mochovce NPPs after repair of Siemens dosemeters eliminating false doses

    International Nuclear Information System (INIS)

    Malysak, J.; Kocvara, S.; Jurochova, B.; Zelenka, Z.; Schacherl, M.; Zrubec, M.; Kaiser, H.

    2003-01-01

    This presentation summarizes the operational experience of the Electronic Personal Dosimetry Systems installed at Dukovany, Temelin and Mochovce NPPs. The system consists of three basic parts: Electronic personal dosemeters (EPD); Physical layer (HW); Logical layer (SW). Number of false doses before and after correction is presented. This presentation has demonstrated the possibilities of SEOD system and the possibility of easy dose comparison between the individual NPPs after introducing this electronic dosimetry system. Basically, the results of film and electronic dosimetry systems are according to our findings nearly identical. Electronic dosemeter sensitivity to interfering electromagnetic fields is a problem which is easily re-movable. In addition, if we know this problem, these false doses in the SEOD system can be easily revealed (e.g. by investigation of histograms) and repaired

  5. Effective dose estimation from the Hp(10) value measured by film OR TL dosemeter located above the lead apron in medical diagnostic and intervention radiology

    International Nuclear Information System (INIS)

    Trousil, J.; Plichta, J.; Petrova, K.

    2001-01-01

    In medical institutions where the diagnostic and intervention radiology is examined the staff personnel doses reach for a long time the annual limit. State Office for Radiation Safety ordered the research task with a view to: (a) the influence of the dosemeter location on different parts of the body on the reliability of E value estimation by means of the value which is measured on the standard body location - left part of the chest above the lead apron. (b) the influence of the protective lead apron (neck, spectacles) with known lead equivalent on the E and H T value determination. In this contribution we present the results of this experimental study including the recommendation for the number and location on the body of dosemeters which are needed for the reliable estimation of E value. (authors)

  6. Determination with a condenser type dosemeter of half value lager of X ray beams generated in the range from 50 to 70 kilovolt

    International Nuclear Information System (INIS)

    Morales Monzon, J.A.

    1994-01-01

    The methodology of half value lager measurement based on ratio of unit output measured before and after an additional 4 mm thick aluminium filter has been installed is studied. The use of a condenser type dosemeter model FJ301G3 produced by Beijing Nuclear Instrument Factory for that purpose is studied too. The study is base on measurement of attenuation curves using high purity aluminium filter done with a dosemeter FJ301G3 and a standard ionization chamber model NE 2530/1 from Nuclear Enterprise respectively. The X ray quality generated had similar characteristic 50 high kerma dose rate series normalized by ISO. Expressions that allow estimate half value lager in aluminium with a maximum deviation of 0,25 mm is reported. The easy handling and low cost of dispositives employed are the main advantages of that methodology. According to voltage range in which study was done, the results have application in quality control of dental X ray units

  7. Electric glass capturing markets

    Energy Technology Data Exchange (ETDEWEB)

    Wikman, K.; Wikstroem, T.

    1996-11-01

    Electric glass has found its place on the construction market. In public buildings, electrically heatable windows are becoming the leading option for large glass walls. Studies on detached houses, both new and renovated, show that floor heating combined with electrically heatable windowpanes is the best choice with respect to resident`s comfort. (orig.)

  8. Radioresistance of inorganic glasses

    International Nuclear Information System (INIS)

    Vorob'ev, A.A.; Zavadovskaya, E.K.; Fedorov, B.V.; Starodubtsev, V.A.

    1977-01-01

    Regularities are considered in the variation of properties of glass due to irradiations. On the basis of previous theoretical statements and experimental investigations, it is inferred that the irradiation resistance of glasses of the same type, synthesis conditions, content of impurities and amount of imperfections, is a function of the ''element-oxygen'' bond energy. The irradiation resistance depends on the number and the nature of glass structure imperfections. The averaged level of bonding forces is indicative of the glass formation temperature; the imperfections in glasses are formed in structure elements whose amount predominates as compared to the others. Electric charges which accumulate on the crack surface tend to increase its size, thus lessening even further the electric strength of the dielectric. The greater the irradiation time, the greater the number of irradiation imperfections causing a drop in the electric strength of glass. When choosing a glass for service in a radiation field, it is necessary to select those of a highest temperature of glass formation and with a least amount of imperfections

  9. Nucleation in ZBLAN glasses

    NARCIS (Netherlands)

    de Leede, G.L.A.; Waal, de H.

    1989-01-01

    Nucleation rates were detd. in a ZrF4-BaF2-NaF-LaF3-AlF3 glass (ZBLAN) using an optical method. The results were compared with a similar glass having a slightly different compn. The difference in the nucleation rate is explained by classical nucleation theory using calcd. free-energy differences

  10. Mechanical relaxation in glasses

    International Nuclear Information System (INIS)

    Hiki, Y.

    2004-01-01

    The basic properties of glasses and the characteristics of mechanical relaxation in glasses were briefly reviewed, and then our studies concerned were presented. Experimental methods adopted were viscosity, internal friction, ultrasonic attenuation, and Brillouin scattering measurements. The specimens used were several kinds of inorganic, organic, and metallic glasses. The measurements were mainly carried out from the room temperature up to the glass transition temperature, and the relaxation time was determined as a function of temperature. The 'double relaxation' composed of two Arrhenius-type relaxations was observed in many materials. In both relaxations, the 'compensation effect' showing a correlation of the pre-exponential factor and the activation energy was observed. These results were explained by considering the 'complex relaxation' due to cooperative motions of atoms or group of atoms. Values of activation energy near the glass transition determined by the various experimental methods were compared with each other

  11. Polymorphism in glasses

    International Nuclear Information System (INIS)

    Landa, L.M.; Nikolaeva, I.N.

    1979-01-01

    To defect phase interfaces and spasmodic properties change, the inhomogeneity and the second radiation effects in quartz glass, metamict phase and intermediate states have been investigated. When irradiating with fast neutrons the transformation of quartz glass - metamict phase occurs completely. The transformation is completed at 2x10 20 part./cm 2 dose. Thermal treatment not only increases the number of inhomogeneities but also results in increasing quartz glass density. Annealing transforms the metamict phase into common quartz glass at 1400 K. The fact, that thermal treatment results in the complete transformation of metamict phase into quartz glass, and the inverse transformation occurs only partially, is quite regular, as the metamict phase has a lesser entropy and is a more ordered state. It is shown that different amorphous phases of a chemical composition have different structures and properties, that there are interfaces between them, and the transformation from one state to another in microvolumes is realized spasmodically and requires expenditure of energy

  12. Determination of the dose index in computerized tomography using thermoluminescent dosemeters; Determinacion del indice de dosis en tomografia computada usando dosimetros termoluminiscentes

    Energy Technology Data Exchange (ETDEWEB)

    Azorin, J.C.; Calderon, A. [Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada-IPN, 11500 Mexico D.F. (Mexico); Azorin, J. [UAM-I, 09340 Mexico D.F. (Mexico)

    2004-07-01

    In this work the obtained results of the determination of the dose index are presented in thorax studies in computed tomography and helical tomography carried out in Mexico using thermoluminescent dosemeters of LiF: Mg,Cu,P + Ptfe developed and manufactured in our country. The results showed that under similar conditions of irradiation and operation (pitch = 1), significant differences don't exist among the doses absorbed measures in the phantom due to the two types of used tomographs. (Author)

  13. Glass leaching performance

    International Nuclear Information System (INIS)

    Chick, L.A.; Turcotte, R.P.

    1983-05-01

    Current understanding of the leaching performance of high-level nuclear waste (HLW) glass is summarized. The empirical model of waste glass leaching behavior developed shows that at high water flow rates the glass leach rate is kinetically limited to a maximum value. At intermediate water flow rates, leaching is limited by the solution concentration of silica and decreases with decreasing water flow rates. Release of soluble elements is controlled by silica dissolution because silica forms the binding network of the glass. At low water flow rates, mass loss rates reach values controlled by formation rates of alteration minerals, or by diffusion of dissolution products through essentially stagnant water. The parameters reviewed with respect to their quantifiable influence on leaching behavior include temperature, pH, leachant composition, glass composition, thermal history, and radiation. Of these, temperature is most important since the rate of mass loss approximately doubles with each 10 0 C increase in dilute solutions. The pH has small effects within the 4 to 10 range. The chemical composition of the leachant is most important with regard to its influence on alteration product formation. Glass composition exhibits the largest effects at high flow rates where improved glasses leach from ten to thirty times slower than glass 76 to 68. The effects of the thermal history (devitrification) of the glass are not likely to be significant. Radiation effects are important primarily in that radiolysis can potentially drive pH values to less than 4. Radiation damage to the glass causes insignificant changes in leaching performance

  14. Development of a fibre-optic dosemeter to measure the skin dose and percentage depth dose in the build-up region of therapeutic photon beams

    International Nuclear Information System (INIS)

    Kim, K. A.; Yoo, W. J.; Jang, K. W.; Moon, J.; Han, K. T.; Jeon, D.; Park, J. Y.; Cha, E. J.; Lee, B.

    2013-01-01

    In this study, a fibre-optic dosemeter (FOD) using an organic scintillator with a diameter of 0.5 mm for photon-beam therapy dosimetry was fabricated. The fabricated dosemeter has many advantages, including water equivalence, high spatial resolution, remote sensing and real-time measurement. The scintillating light generated from an organic-dosemeter probe embedded in a solid-water stack phantom is guided to a photomultiplier tube and an electrometer via 20 m of plastic optical fibre. Using this FOD, the skin dose and the percentage depth dose in the build-up region according to the depths of a solid-water stack phantom are measured with 6- and 15-MV photon-beam energies with field sizes of 10310 and 20320 cm 2 , respectively. The results are compared with those measured using conventional dosimetry films. It is expected that the proposed FOD can be effectively used in radiotherapy dosimetry for accurate measurement of the skin dose and the depth dose distribution in the build-up region due to its high spatial resolution. (authors)

  15. Comparison of responses of thermoluminescent dosemeters irradiated by soft x-rays at very low and very high dose rate levels

    International Nuclear Information System (INIS)

    Pietrikova-Farnikova, M.; Krasa, J.; Juha, L.

    1994-01-01

    Recent great progress in construction and application of bright sources of soft X-rays gave a strong impetus for the development of methods of their dosimetric diagnostics. The soft X-ray sources are primarily represented by synchrotron radiation sources and by sources based on laser-produced plasma, including X-ray lasers. Their characteristics spread over a very wide region of photon energies, peak and average powers and densities. From our preliminary experiments it follows that thermoluminescent dosemeters can serve as a suitable tool for the determination of these characteristics. Problem lies in the fact that routine use of the thermoluminescent dosemeters for the dosimetry of soft X-rays requires their spectral calibration, which can be carried out with low peak power sources (synchrotron radiation and radionuclide sources). On the contrary, many important sources, especially these based on laser-produced plasmas, exhibit a very high peak power, i.e. dosemeters are irradiated at extremely high dose rate. In comparative experiments carried out with laser-produced plasmas and radionuclides using TLD 200 (CaF 2 :Dy) and GR 200A (LiF:Mg,Cu,P) it was satisfactorily proven that total thermoluminescent signals are independent of the dose rate. Dependence of glow curve shapes on the dose, dose rate and photon energy were equally determined

  16. MCNP SIMULATION OF THE HP(10) ENERGY RESPONSE OF A BRAZILIAN TLD ALBEDO NEUTRON INDIVIDUAL DOSEMETER, FROM THERMAL TO 20 MeV.

    Science.gov (United States)

    Freitas, B M; Martins, M M; Pereira, W W; da Silva, A X; Mauricio, C L P

    2016-09-01

    The Brazilian Instituto de Radioproteção e Dosimetria (IRD) runs a neutron individual monitoring system with a home-made TLD albedo dosemeter. It has already been characterised and calibrated in some reference fields. However, the complete energy response of this dosemeter is not known, and the calibration factors for all monitored workplace neutron fields are difficult to be obtained experimentally. Therefore, to overcome such difficulties, Monte Carlo simulations have been used. This paper describes the simulation of the HP(10) neutron response of the IRD TLD albedo dosemeter using the MCNPX transport code, for energies from thermal to 20 MeV. The validation of the MCNPX modelling is done comparing the simulated results with the experimental measurements for ISO standard neutron fields of (241)Am-Be, (252)Cf, (241)Am-B and (252)Cf(D2O) and also for (241)Am-Be source moderated with paraffin and silicone. Bare (252)Cf are used for normalisation. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Investigation of dosimetric characteristics of the high sensitivity LiF:Mg,Cu,P Thermoluminescent Dosemeter and its applications in diagnostic radiology - a review

    Energy Technology Data Exchange (ETDEWEB)

    Fung, K.L. E-mail: orkarl@polyu.edu.hk

    2004-05-01

    This study investigated the dosimetric properties of the high sensitivity TLD (Thermoluminescent Dosemeter) of LiF:Mg,Cu,P and its applications in diagnostic radiology. A reproducible readout and annealing regime for this high sensitivity TLD was developed in the initial part of this study with the newly installed automatic TLD Reader system. Basic dosimetric characteristics of this T.L. dosemeter were then investigated. This paved the foundation for subsequent selected novel application studies in diagnostic radiology. This study exploits the favourable dosimetric properties of these T.L. dosemeters in some selected novel dosimetric applications in diagnostic radiology with an anthropomorphic phantom. The applications studied in radiological procedures included: dose reduction in lumbar spine radiography utilizing the 'anode heel effect'; gonad dose variation with kV{sub p} in chest radiography; foetal dose comparison between computed tomography (CT) and computed radiography (CR) in X-ray pelvimetry; lens dose reduction with bismuth eye-shields in CT brain studies; foetal dose assessment of early pregnancy in common high risk radiological examinations. It is anticipated that the unique and favourable dosimetric performance of LiF:Mg,Cu,P T.L. phosphor will be exploited further in measurements of low level dose received by patients and staff in diagnostic radiological procedures such as paediatric X-ray examinations.

  18. Investigation of dosimetric characteristics of the high sensitivity LiF:Mg,Cu,P Thermoluminescent Dosemeter and its applications in diagnostic radiology - a review

    International Nuclear Information System (INIS)

    Fung, K.L.

    2004-01-01

    This study investigated the dosimetric properties of the high sensitivity TLD (Thermoluminescent Dosemeter) of LiF:Mg,Cu,P and its applications in diagnostic radiology. A reproducible readout and annealing regime for this high sensitivity TLD was developed in the initial part of this study with the newly installed automatic TLD Reader system. Basic dosimetric characteristics of this T.L. dosemeter were then investigated. This paved the foundation for subsequent selected novel application studies in diagnostic radiology. This study exploits the favourable dosimetric properties of these T.L. dosemeters in some selected novel dosimetric applications in diagnostic radiology with an anthropomorphic phantom. The applications studied in radiological procedures included: dose reduction in lumbar spine radiography utilizing the 'anode heel effect'; gonad dose variation with kV p in chest radiography; foetal dose comparison between computed tomography (CT) and computed radiography (CR) in X-ray pelvimetry; lens dose reduction with bismuth eye-shields in CT brain studies; foetal dose assessment of early pregnancy in common high risk radiological examinations. It is anticipated that the unique and favourable dosimetric performance of LiF:Mg,Cu,P T.L. phosphor will be exploited further in measurements of low level dose received by patients and staff in diagnostic radiological procedures such as paediatric X-ray examinations

  19. Thermal Conductivity of Foam Glass

    DEFF Research Database (Denmark)

    Petersen, Rasmus Rosenlund; König, Jakob; Yue, Yuanzheng

    Due to the increased focus on energy savings and waste recycling foam glass materials have gained increased attention. The production process of foam glass is a potential low-cost recycle option for challenging waste, e.g. CRT glass and industrial waste (fly ash and slags). Foam glass is used...... as thermal insulating material in building and chemical industry. The large volume of gas (porosity 90 – 95%) is the main reason of the low thermal conductivity of the foam glass. If gases with lower thermal conductivity compared to air are entrapped in the glass melt, the derived foam glass will contain...... only closed pores and its overall thermal conductivity will be much lower than that of the foam glass with open pores. In this work we have prepared foam glass using different types of recycled glasses and different kinds of foaming agents. This enabled the formation of foam glasses having gas cells...

  20. Some studies about the NaCl:Ca2+ :Mn2+ and NaCl: Cd2+ :Mn2+ dosemeters

    International Nuclear Information System (INIS)

    Verdiguel G, H.; Flores J, C.; Camarillo G, E.; Espejel P, R.; Cabrera B, E.; Hernandez A, J.; Murrieta S, H.; Cruz Z, E.; Ramos B, S.; Negron, A.

    2002-01-01

    Nowadays, a great interest by counting with dosemeters of characteristics such as a high stability, of easy operation and easier production exists. Looking for a commitment with all these characteristics,a possibility to use the system NaCl: Ca 2+ :Mn 2+ and NaCl: Cd 2+ :Mn 2+ as dosemeters was studied. The studies were realized irradiating with gamma radiation from a 60 Co source. The crystals that were used as samples did not suffer any thermal treatment previous to irradiation. The supplied doses were 10, 30, 60, 100, 300, and 600 rads. 24 hours after irradiation the thermoluminescent response was obtained. In the case of the system NaCl: Ca 2+ :Mn 2+ several thermoluminescent bands were observed (BTL). Two concentrations of Mn 2+ with only one concentration of Ca 2+ (1%) were studied. For the case of the smaller concentration of Mn 2+ (0.1%) 4 BTL were observed, whereas for a greater concentration (0.3%) just 2 BTL were detected. The positions of the maximum of the BTL peaks differ for both concentrations, this possible due to what the nature of the traps for both cases differs by the type of precipitates present in the net. For the case of the system NaCl: Cd 2+ (1%) :Mn 2+ (0.1% and 0.5%) a similar situation to the previous was found, although in this case for both manganese concentrations just 2 BTL were observed; however all the peaks seem to be the superposition of several bands. Despite the apparent complexity of the thermoluminescent response, such response as function of the dose shows that both systems present a stable response to gamma radiation in the interval from 10 to 600 rads. In the case of calcium it is had a response of linear type of the Tl intensity depending on the dose, whereas for the cadmium system a supra linear response seems to exist. Nowadays, studies for determining the BTL origin being carried out. (Author)

  1. Effect of different glasses in glass bonded zeolite

    International Nuclear Information System (INIS)

    Lewis, M.A.; Ackerman, J.P.; Verma, S.

    1995-01-01

    A mineral waste form has been developed for chloride waste salt generated during the pyrochemical treatment of spent nuclear fuel. The waste form consists of salt-occluded zeolite powders bound within a glass matrix. The zeolite contains the salt and immobilizes the fission products. The zeolite powders are hot pressed to form a mechanically stable, durable glass bonded zeolite. Further development of glass bonded zeolite as a waste form requires an understanding of the interaction between the glass and the zeolite. Properties of the glass that enhance binding and durability of the glass bonded zeolite need to be identified. Three types of glass, boroaluminosilicate, soda-lime silicate, and high silica glasses, have a range of properties and are now being investigated. Each glass was hot pressed by itself and with an equal amount of zeolite. MCC-1 leach tests were run on both. Soda-lime silicate and high silica glasses did not give a durable glass bonded zeolite. Boroaluminosilicate glasses rich in alkaline earths did bind the zeolite and gave a durable glass bonded zeolite. Scanning electron micrographs suggest that the boroaluminosilicate glasses wetted the zeolite powders better than the other glasses. Development of the glass bonded zeolite as a waste form for chloride waste salt is continuing

  2. Oxynitride glasses: a review

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, A.R.; Clausell, C.; Barba, A.

    2016-07-01

    Oxynitride glasses are special types of silicates or silicoaluminates which have been the object of many studies over the last forty years. They can be prepared by means of various complex methods, leading to variable levels of nitrogen incorporation, though in all cases giving limited transparency in the visible range. More recently, a new family of oxynitride glasses incorporating fluorine has been investigated. This paper outlines the effect of composition, in particular nitrogen and fluorine content, on properties such as glass transition temperature, hardness, Young's modulus, compactness and molar volume. (Author)

  3. Orbital glass in HTSC

    International Nuclear Information System (INIS)

    Kusmartsev, F.V.

    1992-10-01

    The physical reasons why the orbital glass may exist in granular high-temperature superconductors and the existing experimental data appeared recently are discussed. The orbital glass is characterized by the coexistence of the orbital paramagnetic state with the superconducting state and occurs at small magnetic fields H c0 c1 . The transition in orbital glass arises at the critical field H c0 which is inversely proportional to the surface cross-area S of an average grain. In connection with theoretical predictions the possible experiments are proposed. (author). 10 refs

  4. Bioactive glasses and glass-ceramics

    Directory of Open Access Journals (Sweden)

    de Aza, P. N.

    2007-04-01

    Full Text Available Since the late 1960´s, a great interest in the use of bioceramic materials for biomedical applications has been developed. In a previous paper, the authors reviewed crystalline bioceramic materials “sensus stricto”, it is to say, those ceramic materials, constituted for non-metallic inorganic compounds, crystallines and consolidates by thermal treatment of powders at high temperature. In the present review, the authors deal with those called bioactive glasses and glassceramics. Although all of them are also obtained by thermal treatment at high temperature, the first are amorphous and the second are obtained by devitrification of a glass, although the vitreous phase normally prevails on the crystalline phases. After an introduction to the concept of bioactive materials, a short historical review of the bioactive glasses development is made. Its preparation, reactivity in physiological media, mechanism of bonding to living tissues and mechanical strength of the bone-implant interface is also reported. Next, the concept of glass-ceramic and the way of its preparation are exposed. The composition, physicochemical properties and biological behaviour of the principal types of bioactive glasses and glass-ceramic materials: Bioglass®, Ceravital®, Cerabone®, Ilmaplant® and Bioverit® are also reviewed. Finally, a short review on the bioactive-glass coatings and bioactive-composites and most common uses of bioactive-glasses and glass-ceramics are carried out too.

    Desde finales de los años sesenta, se ha despertado un gran interés por el uso de los materiales biocerámicos para aplicaciones biomédicas. En un trabajo previo, los autores hicieron una revisión de los denominados materiales biocerámicos cristalinos en sentido estricto, es decir, de aquellos materiales, constituidos por compuestos inorgánicos no metálicos, cristalinos y consolidados mediante tratamientos térmicos a altas temperaturas. En el presente trabajo, los autores

  5. Fun with Singing Wine Glasses

    Science.gov (United States)

    Boone, Christine; Galloway, Melodie; Ruiz, Michael J.

    2018-01-01

    A fun activity is presented using singing wine glasses for introductory physics students. Students tune a white wine glass and a red wine glass to as many semitones as possible by filling the glasses with the appropriate amounts of water. A smart phone app is used to measure the frequencies of equal-temperament tones. Then plots of frequency…

  6. Waste glass weathering

    International Nuclear Information System (INIS)

    Bates, J.K.; Buck, E.C.

    1994-01-01

    The weathering of glass is reviewed by examining processes that affect the reaction of commercial, historical, natural, and nuclear waste glass under conditions of contact with humid air and slowly dripping water, which may lead to immersion in nearly static solution. Radionuclide release data from weathered glass under conditions that may exist in an unsaturated environment are presented and compared to release under standard leaching conditions. While the comparison between the release under weathering and leaching conditions is not exact, due to variability of reaction in humid air, evidence is presented of radionuclide release under a variety of conditions. These results suggest that both the amount and form of radionuclide release can be affected by the weathering of glass

  7. Super ionic conductive glass

    Science.gov (United States)

    Susman, S.; Volin, K.J.

    Described is an ionically conducting glass for use as a solid electrolyte in a power or secondary cell containing an alkali metal-containing anode and a cathode separated by an alkali metal ion conducting glass having an ionic transference number of unity and the general formula: A/sub 1 + x/D/sub 2-x/3/Si/sub x/P/sub 3 - x/O/sub 12 - 2x/3/, wherein A is a network modifier for the glass and is an alkali metal of the anode, D is an intermediate for the glass and is selected from the class consisting of Zr, Ti, Ge, Al, Sb, Be, and Zn and X is in the range of from 2.25 to 3.0. Of the alkali metals, Na and Li are preferred and of the intermediate, Zr, Ti and Ge are preferred.

  8. Phosphate glasses, containing nitrogen

    International Nuclear Information System (INIS)

    Lisitsyna, E.A.; Khalilev, V.D.; Koryavin, A.A.; Goncharova, L.N.

    1987-01-01

    Possibilities of nitrogen-containing glass synthesis by the introduction into the charge of ammonium salts, as well as aluminium nitride, are studied. Zinc alumoyttrium phosphate glass (mol. %) Zn(PO 3 ) 2 - 4O, Al(PO 3 ) 3 - 3O, Y(PO 3 ) 3 -3O is suggested as a matrix. It is shown that the effect of amide and imide groups on the properties of the glass is less noticeable than the effect of nitride groups. Direct introduction of nitride constituent was realized using AlN, but aluminium introduction was taken into account so that the oxide was subtracted. The attempt to introduce more than 2.5 mass % of nitrogen into initial matrix by aluminium nitride has failed due to repeated restoration of glass with amorphous phosphorus isolation

  9. Baseline LAW Glass Formulation Testing

    International Nuclear Information System (INIS)

    Kruger, Albert A.; Mooers, Cavin; Bazemore, Gina; Pegg, Ian L.; Hight, Kenneth; Lai, Shan Tao; Buechele, Andrew; Rielley, Elizabeth; Gan, Hao; Muller, Isabelle S.; Cecil, Richard

    2013-01-01

    The major objective of the baseline glass formulation work was to develop and select glass formulations that are compliant with contractual and processing requirements for each of the LAW waste streams. Other objectives of the work included preparation and characterization of glasses with respect to the properties of interest, optimization of sulfate loading in the glasses, evaluation of ability to achieve waste loading limits, testing to demonstrate compatibility of glass melts with melter materials of construction, development of glass formulations to support ILAW qualification activities, and identification of glass formulation issues with respect to contract specifications and processing requirements

  10. Measurement of doses to aviator pilots using thermoluminescent dosemeters; Medicion de la dosis a pilotos aviadores usando dosimetros termoluminiscentes

    Energy Technology Data Exchange (ETDEWEB)

    Azorin N, J.; Cruz C, D. [UAM-I, 09340 Mexico D.F. (Mexico); Rivera M, T. [IPN, ESIME Culhuacan (Mexico)]. e-mail: azorin@xanum.uam.mx

    2004-07-01

    During the development of their work, the aviator pilots are exposed at high levels of natural radiation of bottom caused mainly by the cosmic radiation of galactic origin and lot. For such reason, the Metropolitan Autonomous University (UAM) and the Union Association of Aviator Pilots (ASPA), subscribed an agreement with the purpose of to measure the doses of ionizing radiation received by the aviator pilots of diverse air companies that man different types of airships and to determine if these doses surpass the one limit of 0.11 mSv/h settled down by the IAEA for the public in general; and if therefore, these workers should be considered as personnel occupationally exposed. In this work the obtained results when measuring the absorbed dose received by Mexican civil aviator pilots during the development of their work, using thermoluminescent dosemeters of LiF:Mg,Cu,P + Ptfe of national production are presented. The obtained results during the years of 2001 and 2002 show that the monthly doses received by the pilots surpass the one it limits established for the public in general, for what they should be considered as personnel occupationally exposed. (Author)

  11. Study of charge reader probes for electret dosemeters; Estudo de sondas leitoras de carga para dosimetros de eletretos

    Energy Technology Data Exchange (ETDEWEB)

    Parada, Marco A.; Silva, Nivaldo C. da; Almeida, Adelaide de [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras. Dept. de Fisica e Matematica

    2001-07-01

    Electrets are insulating materials with a quasi-permanent polarization. It can be made from carnauba wax, Teflon and other materials for several applications as transducers, electrophotography, high efficiency air filters and as radiation dosimeters. Electret dosemeters may be used for {alpha}, {beta}, {gamma}, X, e{sup -} and neutrons radiations with a low construction cost and a simple associated instrumentation. The probe, for charge measurements of the electret dosimeters, is an important device in the experimental set up and its geometry varies according to the geometry of the dosimeter or the scope of the measurements. In this work the development of several probes is described (cylindrical, 1/3 cylindrical and three points probes with different sizes). From the measurements one can demonstrate that cylindrical probe may be used for cylindrical electret geometry, 1/3 cylindrical probe for measurements of directional dependence of the dose and point probe for scanning measurements of plane areas. For high resolution, small point probe may be used and for high sensitivity, the probe-electret distance must be minimized taking account of the Paschen discharge. (author)

  12. Assessment of effective radiation dose of an extremity CBCT, MSCT and conventional X ray for knee area using MOSFET dosemeters.

    Science.gov (United States)

    Koivisto, Juha; Kiljunen, Timo; Wolff, Jan; Kortesniemi, Mika

    2013-12-01

    The objective of this study was to assess and compare the organ and effective doses in the knee area resulting from different commercially available multislice computed tomography devices (MSCT), one cone beam computed tomography device (CBCT) and one conventional X-ray radiography device using MOSFET dosemeters and an anthropomorphic RANDO knee phantom. Measurements of the MSCT devices resulted in effective doses ranging between 27 and 48 µSv. The CBCT measurements resulted in an effective dose of 12.6 µSv. The effective doses attained using the conventional radiography device were 1.8 µSv for lateral and 1.2 µSv for anterior-posterior projections. The effective dose resulting from conventional radiography was considerably lower than those recorded for the CBCT and MSCT devices. The MSCT effective dose results were two to four times higher than those measured on the CBCT device. This study demonstrates that CBCT can be regarded as a potential low-dose 3D imaging technique for knee examinations.

  13. An energy and direction independent fast neutron dosemeter based on electrochemically etched CR-39 nuclear track detectors

    International Nuclear Information System (INIS)

    James, K.; Matiullah; Durrani, S.A.

    1987-01-01

    A computer-based model is presented, which simulates the dose equivalent response of electrochemically etched CR-39 to fast neutrons of various energies and angles of incidence. Most previous calculations of the response of CR-39 have neglected the production of recoiling oxygen and carbon nuclei as well as α particles in the CR-39. We calculate that these 'heavy recoils' and α particles are the major source of electrochemically etchable tracks in bare CR-39 at neutron energies above approx. 2 MeV under typical etching conditions. Our calculations have been extended to predict the response of CR-39 used in conjunction with various combinations of polymeric front radiators and we have determined the radiator stack configuration with produces the most energy independent response. Again, the heavy recoils and α particles cannot be neglected and, for energies above approx. 2 MeV, these produce typically about 20% of the total response of our optimum stack. This type of fast neutron dosemeter is, however, strongly direction dependent. We have integrated the response over all appropriate angles to predict the dose equivalent response for two representative neutron fields, and we suggest a method for minimising the angular dependence. (author)

  14. NUCLEAR HEATING IN LIF DOSEMETERS IN A FUSION NEUTRON FIELD, TRIAL OF DIRECT COMPARISON OF EXPERIMENTAL AND SIMULATED RESULTS.

    Science.gov (United States)

    Pohorecki, Wladyslaw; Obryk, Barbara

    2017-09-29

    The results of nuclear heating measured by means of thermoluminescent dosemeters (TLD-LiF) in a Cu block irradiated by 14 MeV neutrons are presented. The integral Cu experiment relevant for verification of copper nuclear data at neutron energies characteristic for fusion facilities was performed in the ENEA FNG Laboratory at Frascati. Five types of TLDs were used: highly photon sensitive LiF:Mg,Cu,P (MCP-N), 7LiF:Mg,Cu,P (MCP-7) and standard, lower sensitivity LiF:Mg,Ti (MTS-N), 7LiF:Mg,Ti (MTS-7) and 6LiF:Mg,Ti (MTS-6). Calibration of the detectors was performed with gamma rays in terms of air-kerma (10 mGy of 137Cs air-kerma). Nuclear heating in the Cu block was also calculated with the use of MCNP transport code Nuclear heating in Cu and air in TLD's positions was calculated as well. The nuclear heating contribution from all simulated by MCNP6 code particles including protons, deuterons, alphas tritons and heavier ions produced by the neutron interactions were calculated. A trial of the direct comparison between experimental results and results of simulation was performed. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Wastes based glasses and glass-ceramics

    Directory of Open Access Journals (Sweden)

    Barbieri, L.

    2001-12-01

    Full Text Available Actually, the inertization, recovery and valorisation of the wastes coming from municipal and industrial processes are the most important goals from the environmental and economical point of view. An alternative technology capable to overcome the problem of the dishomogeneity of the raw material chemical composition is the vitrification process that is able to increase the homogeneity and the constancy of the chemical composition of the system and to modulate the properties in order to address the reutilization of the waste. Moreover, the glasses obtained subjected to different controlled thermal treatments, can be transformed in semy-cristalline material (named glass-ceramics with improved properties with respect to the parent amorphous materials. In this review the tailoring, preparation and characterization of glasses and glass-ceramics obtained starting from municipal incinerator grate ash, coal and steel fly ashes and glass cullet are described.

    Realmente la inertización, recuperación y valorización de residuos que proceden de los procesos de incineración de residuos municipales y de residuos industriales son metas importantes desde el punto de vista ambiental y económico. Una tecnología alternativa capaz de superar el problema de la heterogeneidad de la composición química de los materiales de partida es el proceso de la vitrificación que es capaz de aumentar la homogeneidad y la constancia de la composición química del sistema y modular las propiedades a fin de la reutilización del residuo. En este artículo se presentan los resultados de vitrificación en que los vidrios fueron sometidos a tratamientos térmicos controlados diferentes, de manera que se transforman en materiales semicristalinos (también denominados vitrocerámicos con mejores propiedades respecto a los materiales amorfos originales. En esta revisión se muestra el diseño, preparación y caracterización de vidrios y vitrocerámicos partiendo de

  16. Optimized Synthesis of Foam Glass from Recycled CRT Panel Glass

    DEFF Research Database (Denmark)

    Petersen, Rasmus Rosenlund; König, Jakob; Yue, Yuanzheng

    Most of the panel glass from cathode ray tubes (CRTs) is landfilled today. Instead of landfilling, the panel glass can be turned into new environment-friendly foam glass. Low density foam glass is an effective heat insulating material and can be produced just by using recycle glass and foaming...... additives. In this work we recycle the CRT panel glass to synthesize the foam glass as a crucial component of building and insulating materials. The synthesis conditions such as foaming temperature, duration, glass particle size, type and concentrations of foaming agents, and so on are optimized...... by performing systematic experiments. In particular, the concentration of foaming agents is an important parameter that influences the size of bubbles and the distribution of bubbles throughout the sample. The foam glasses are characterised regarding density and open/closed porosity. Differential scanning...

  17. DWPF GLASS BEADS AND GLASS FRIT TRANSPORT DEMONSTRATION

    Energy Technology Data Exchange (ETDEWEB)

    Adamson, D; Bradley Pickenheim, B

    2008-11-24

    DWPF is considering replacing irregularly shaped glass frit with spherical glass beads in the Slurry Mix Evaporator (SME) process to decrease the yield stress of the melter feed (a non-Newtonian Bingham Plastic). Pilot-scale testing was conducted on spherical glass beads and glass frit to determine how well the glass beads would transfer when compared to the glass frit. Process Engineering Development designed and constructed the test apparatus to aid in the understanding and impacts that spherical glass beads may have on the existing DWPF Frit Transfer System. Testing was conducted to determine if the lines would plug with the glass beads and the glass frit slurry and what is required to unplug the lines. The flow loop consisted of vertical and horizontal runs of clear PVC piping, similar in geometry to the existing system. Two different batches of glass slurry were tested: a batch of 50 wt% spherical glass beads and a batch of 50 wt% glass frit in process water. No chemicals such as formic acid was used in slurry, only water and glass formers. The glass beads used for this testing were commercially available borosilicate glass of mesh size -100+200. The glass frit was Frit 418 obtained from DWPF and is nominally -45+200 mesh. The spherical glass beads did not have a negative impact on the frit transfer system. The transferring of the spherical glass beads was much easier than the glass frit. It was difficult to create a plug with glass bead slurry in the pilot transfer system. When a small plug occurred from setting overnight with the spherical glass beads, the plug was easy to displace using only the pump. In the case of creating a man made plug in a vertical line, by filling the line with spherical glass beads and allowing the slurry to settle for days, the plug was easy to remove by using flush water. The glass frit proved to be much more difficult to transfer when compared to the spherical glass beads. The glass frit impacted the transfer system to the point

  18. DWPF GLASS BEADS AND GLASS FRIT TRANSPORT DEMONSTRATION

    International Nuclear Information System (INIS)

    Adamson, D.; Pickenheim, Bradley

    2008-01-01

    DWPF is considering replacing irregularly shaped glass frit with spherical glass beads in the Slurry Mix Evaporator (SME) process to decrease the yield stress of the melter feed (a non-Newtonian Bingham Plastic). Pilot-scale testing was conducted on spherical glass beads and glass frit to determine how well the glass beads would transfer when compared to the glass frit. Process Engineering Development designed and constructed the test apparatus to aid in the understanding and impacts that spherical glass beads may have on the existing DWPF Frit Transfer System. Testing was conducted to determine if the lines would plug with the glass beads and the glass frit slurry and what is required to unplug the lines. The flow loop consisted of vertical and horizontal runs of clear PVC piping, similar in geometry to the existing system. Two different batches of glass slurry were tested: a batch of 50 wt% spherical glass beads and a batch of 50 wt% glass frit in process water. No chemicals such as formic acid was used in slurry, only water and glass formers. The glass beads used for this testing were commercially available borosilicate glass of mesh size -100+200. The glass frit was Frit 418 obtained from DWPF and is nominally -45+200 mesh. The spherical glass beads did not have a negative impact on the frit transfer system. The transferring of the spherical glass beads was much easier than the glass frit. It was difficult to create a plug with glass bead slurry in the pilot transfer system. When a small plug occurred from setting overnight with the spherical glass beads, the plug was easy to displace using only the pump. In the case of creating a man made plug in a vertical line, by filling the line with spherical glass beads and allowing the slurry to settle for days, the plug was easy to remove by using flush water. The glass frit proved to be much more difficult to transfer when compared to the spherical glass beads. The glass frit impacted the transfer system to the point

  19. Nuclear waste glass corrosion mechanisms

    International Nuclear Information System (INIS)

    Jantzen, C.M.

    1987-04-01

    Dissolution of nuclear waste glass occurs by corrosion mechanisms similar to those of other solids, e.g., metallurgical and mineralogic systems. Metallurgical phenomena such as active corrosion, passivation and immunity have been observed to be a function of the glass composition and the solution pH. Hydration thermodynamics was used to quantify the role of glass composition and its effect on the solution pH during dissolution. A wide compositional range of natural, lunar, medieval, and nuclear waste glasses, as well as some glass-ceramics were investigated. The factors observed to affect dissolution in deionized water are pertinent to the dissolution of glass in natural environments such as the groundwaters anticipated to interact with nuclear waste glass in a geologic repository. The effects of imposed pH and oxidation potential (Eh) conditions existing in natural environments on glass dissolution is described in the context of Pourbaix diagrams, pH potential diagrams, for glass

  20. Electrical properties of phosphate glasses

    International Nuclear Information System (INIS)

    Mogus-Milankovic, A; Santic, A; Reis, S T; Day, D E

    2009-01-01

    Investigation of the electrical properties of phosphate glasses where transition metal oxide such as iron oxide is the network former and network modifier is presented. Phosphate glasses containing iron are electronically conducting glasses where the polaronic conduction is due to the electron hopping from low to high iron valence state. The identification of structural defects caused by ion/polaron migration, the analysis of dipolar states and electrical conductivity in iron phosphate glasses containing various alkali and mixed alkali ions was performed on the basis of the impedance spectroscopy (IS). The changes in electrical conductivity from as-quenched phosphate glass to fully crystallized glass (glass-ceramics) by IS are analyzed. A change in the characteristic features of IS follows the changes in glass and crystallized glass network. Using IS, the contribution of glass matrix, crystallized grains and grain boundary to the total electrical conductivity for iron phosphate glasses was analyzed. It was shown that decrease in conductivity is caused by discontinuities in the conduction pathways as a result of the disruption of crystalline network where two or more crystalline phases are formed. Also, phosphate-based glasses offer a unique range of biomaterials, as they form direct chemical bonding with hard/soft tissue. The surface charges of bioactive glasses are recognized to be the most important factors in determining biological responses. The improved bioactivity of the bioactive glasses as a result of the effects of the surface charges generated by electrical polarization is discussed.

  1. Theory of glass

    International Nuclear Information System (INIS)

    Rivier, N.

    1985-01-01

    The physical properties of glass are direct consequences of its non-crystalline structure. The structure is described from a topological point of view, since topology is the only geometry surviving non-crystallinity, i.e. absence of metric and trivial space group. This fact has two main consequences: the overall homogeneity of glass is a gauge symmetry, and the only extended, structurally stable constituents are odd lines (or 2π-disclinations in the elastic continuum limit). A gauge theory of glass, based on odd lines as sources of frozen-in strain, can explain those properties of glasses which are both specific to, and universal in amorphous solids: low-temperature excitations, and relaxation at high temperatures. The methods of statistical mechanics can be applied to give a minimal description of amorphous structures in statistical equilibrium. Criteria for statistical equilibrium of the structure and detailed balance are given, together with structural equations of state, which turn out to be well-known empirically among botanists and metallurgists. This review is based on lectures given in 1984 in Niteroi. It contains five parts: I - Structure, from a topological viewpoint; II - gauge invariance; III - Tunneling modes; IV - Supercooled liquid and the glass transitions; V - Statistical crystallography. (Author) [pt

  2. Sol-Gel Glasses

    Science.gov (United States)

    Mukherjee, S. P.

    1985-01-01

    Multicomponent homogeneous, ultrapure noncrystalline gels/gel derived glasses are promising batch materials for the containerless glass melting experiments in microgravity. Hence, ultrapure, homogeneous gel precursors could be used to: (1) investigate the effect of the container induced nucleation on the glass forming ability of marginally glass forming compositions; and (2) investigate the influence of gravity on the phase separation and coarsening behavior of gel derived glasses in the liquid-liquid immiscibility zone of the nonsilicate systems having a high density phase. The structure and crystallization behavior of gels in the SiO2-GeO2 as a function of gel chemistry and thermal treatment were investigated. As are the chemical principles involved in the distribution of a second network former in silica gel matrix being investigated. The procedures for synthesizing noncrystalline gels/gel-monoliths in the SiO2-GeO2, GeO2-PbO systems were developed. Preliminary investigations on the levitation and thermal treatment of germania silicate gel-monoliths in the Pressure Facility Acoustic Levitator were done.

  3. The former tests realized to a personal neutron dosemeter based on solid nuclear tracks detector; Primeras pruebas realizadas a un dosimetro personal de neutrones basado en detectores solidos de trazas nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Camacho, M.E.; Tavera, L.; Balcazar, M. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1997-07-01

    Due to the increase in the use of neutron radiation a personal neutron dosemeter based on solid nuclear tracks detector (DSTN) was designed and constructed. The personal dosemeter design consists of three arrangements. The first one consists of a plastic nuclear tracks detector (LR115 or CR39) in contact with a LiF pellet. The second one is the same that above but it placed among two cadmium pellets and, the third one is formed by the alone detector without converter neither neutron absorber. The three arrangements are placed inside a plastic porta detector hermetically closed to avoid the bottom produced by environmental radon whichever both detectors (LR115 and CR39) are sensitive. In this work the former tests realized to that dosemeter are presented. (Author)

  4. Ion exchange for glass strengthening

    International Nuclear Information System (INIS)

    Gy, Rene

    2008-01-01

    This paper presents a short overview of silicate glass strengthening by exchange of alkali ions in a molten salt, below the glass transition temperature (chemical tempering). The physics of alkali inter-diffusion is briefly explained and the main parameters of the process, which control the glass reinforcement, are reviewed. Methods for characterizing the obtained residual stress state and the strengthening are described, along with the simplified modelling of the stress build-up. The fragmentation of chemically tempered glass is discussed. The concept of engineered stress profile glass is presented, and finally, the effect of glass and salt compositions is overviewed

  5. Evaluation of dose equivalent and identification of energy rangeby the electronic personal dosemeter for neutron 'Saphydose-N' at different workplaces of nuclear facilities

    International Nuclear Information System (INIS)

    Chau, Q.; Lahaye, T.; Lacoste, V.; Muller, H.; Luszik-Bhadra, M.; Reginatto, M.

    2005-01-01

    Full text: According to the transposition of the Directive 96/29/EURATOM into the French legislation, any worker operating in a controlled area has to be monitored by 'passive' and 'active' dosemeters. Electronic personal dosemeters are especially needed for optimization of workplaces. In nuclear facilities, some of the workers are likely to be exposed to mixed neutron-photon fields. If the dosimetry of the photons is relatively well controlled, the neutron dosimetry raises more difficulties. In this context, the Institute for Radiological Protection and Nuclear Safety (IRSN) has developed an electronic device based on a silicon detector: the 'Saphydose-N' dosemeter. It is composed of several detectors and covers more than eight energy decades. The Saphydose-N device complies with recommendations of standard IEC 1323. As the radiation fields produced in laboratory are not strictly representative to those encountered at workplaces, IRSN evaluated the response of Saphydose-N at various workplaces from nuclear industry. Several campaigns were performed in the framework of the European contract EVIDOS ('Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields'). Saphydose-N was carried out at a fuel processing plant, at the Nuclear Power Plant close to the boiling water reactor, near the transport and storage cask and at the Research Reactor. This paper mainly aims at presenting the measurements, the identification of the energy range and the results obtained with the electronic personal neutron Saphydose-N at different facilities. The results are compared with reference values, defined by other partners in EVIDOS project, for ambient and personal dose equivalent. (author)

  6. Perspectives on spin glasses

    CERN Document Server

    Contucci, Pierluigi

    2013-01-01

    Presenting and developing the theory of spin glasses as a prototype for complex systems, this book is a rigorous and up-to-date introduction to their properties. The book combines a mathematical description with a physical insight of spin glass models. Topics covered include the physical origins of those models and their treatment with replica theory; mathematical properties like correlation inequalities and their use in the thermodynamic limit theory; main exact solutions of the mean field models and their probabilistic structures; and the theory of the structural properties of the spin glass phase such as stochastic stability and the overlap identities. Finally, a detailed account is given of the recent numerical simulation results and properties, including overlap equivalence, ultrametricity and decay of correlations. The book is ideal for mathematical physicists and probabilists working in disordered systems.

  7. Waste glass melting stages

    International Nuclear Information System (INIS)

    Anderson, L.D.; Dennis, T.; Elliott, M.L.; Hrma, P.

    1994-01-01

    Three simulated nuclear waste glass feeds, consisting of dried waste and glass frit, were heat treated for 1 hour in a gradient furnace at temperatures ranging from approximately 600 degrees C to 1000 degrees C. Simulated melter feeds from the Hanford Waste Vitrification Plant (HWVP), the Defense Waste Processing Facility (DWPF), and Kernforschungszentru Karlsruhe (KfK) in Germany were used. The samples were thin sectioned and examined by optical microscopy to investigate the stages of the conversion from feed to glass. Various phenomena were seen, such as frit softening, bubble formation, foaming, bubble motion and removal, convective mixing, and homogenization. The behavior of different feeds was similar, although the degree of gas generation and melt homogenization varied. 2 refs., 8 tabs

  8. Waste glass melting stages

    International Nuclear Information System (INIS)

    Anderson, L.D.; Dennis, T.; Elliott, M.L.; Hrma, P.

    1993-04-01

    Three different simulated nuclear waste glass feeds, consisting of dried waste and glass frit, were heat treated for 1 hour in a gradient furnace at temperatures ranging from approximately 600 degrees C--1000 degrees C. Simulated melter feeds from the Hanford Waste Vitrification Plant (HWVP), the Defense Waste Processing Facility (DWPF), and Kernforschungszentrum Karlsruhe (KfK) in Germany were used. The samples were thin-sectioned and examined by optical microscopy to investigate the stages of the conversion from feed to glass. Various phenomena were seen, such as frit softening, bubble formation, foaming, bubble motion and removal, convective mixing, and homogenization. Behavior of different feeds was similar, although the degree of gas generation and melt homogenization varied

  9. Using physical properties of molten glass to estimate glass composition

    International Nuclear Information System (INIS)

    Choi, Kwan Sik; Yang, Kyoung Hwa; Park, Jong Kil

    1997-01-01

    A vitrification process is under development in KEPRI for the treatment of low-and medium-level radioactive waste. Although the project is for developing and building Vitrification Pilot Plant in Korea, one of KEPRI's concerns is the quality control of the vitrified glass. This paper discusses a methodology for the estimation of glass composition by on-line measurement of molten glass properties, which could be applied to the plant for real-time quality control of the glass product. By remotely measuring viscosity and density of the molten glass, the glass characteristics such as composition can be estimated and eventually controlled. For this purpose, using the database of glass composition vs. physical properties in isothermal three-component system of SiO 2 -Na 2 O-B 2 O 3 , a software TERNARY has been developed which determines the glass composition by using two known physical properties (e.g. density and viscosity)

  10. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of peaks of high temperature in TLD-100 dosemeters

    International Nuclear Information System (INIS)

    Flores M, E.

    2007-01-01

    The increase of the applications of ion beams in radiotherapy treatments has generated interest in the study of the thermoluminescent materials (TL) that allow to determine the applied doses. A way to quantify the TL response from these materials to ions is by means of the relative thermoluminescent efficiency. In the group of Thermoluminescent dosimetry of the Institute of Physics of the UNAM (IFUNAM) the thermoluminescent response of the TLD-100 dosemeters has been studied, which present a glow curve characteristic with several peaks that correspond to traps and luminescent centers in the material. The stable peaks know each other as 4, 5, 6a, 6b, 7, 8, 9 and 10. The efficiencies should be measured using the response so much to the radiation of interest (in this case protons and helium ions) as the response to gamma radiation. In previous works with ions of low energy taken place in the Pelletron accelerator of the IFUNAM was only measured the TL efficiency for the peak 5 and the total signal. It had not been possible to measure the efficiency of the peaks of high temperature (6a-10) because, for the gamma radiation, the peaks of high temperature show very small signals; however, recently Massillon carries out measures of efficiency TL of peaks of high temperature for ions of intermediate energy using a protocol special of reading and of deconvolution that allows to measure the signals coming from the peaks of high temperature. In this work is implemented this same protocol to complete the study of TL efficiencies at low energy of protons and helium and to determine if the values of efficiency depend on the used reading protocol. For it is reported it measures of the relative efficiency of the peaks of high temperature from the TLD-100 exposed to protons of 1.5 MeV and nuclei of helium of 3 and 7.5 MeV. (Author)

  11. NOMEX - a universal diagnostic dosemeter, mA.s, and kV meter for acceotance test measurements and quality assurance

    International Nuclear Information System (INIS)

    Hein, G.; Pychlau, P.; Schuele, E.

    1992-01-01

    A universal diagnostic dosemeter is introduced which was designed for acceptance test measurements and quality assurance. It can also be used for periodic constancy checks. To facilitate the comprehensive tests, the NOMEX can measure all important quantities, such as dose and dose rate, mean peak voltage, exposure time, mA.s product, dose per mA.s, dose per pulse, attenuation factor, relative standard deviation and length dose product in CT. All these quantities, except the mA.s product, are measured non-invasively. The instrument's concept, its applications and technical data are described. (author)

  12. Comparison of two models for the X-ray dispersion produced in a Novillo Tokamak with measurements make with thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Flores O, A.; Castillo, A.; Barocio, S.R.; Melendez L, L.; Chavez A, E.; Cruz C, G.J.; Lopez, R.; Olayo, M.G.; Gonzalez M, P.; Azorin N, J.

    1999-01-01

    It was presented the results to study about the X-ray dispersion produced in the Novillo Tokamak using thermoluminescent dosemeters (DTL). The measurements were make in the equatorial plane of Tokamak, along twelve radial directions. The dispersion is observed due to the radiation interaction with walls surrounding the machine. It was proposed two types of heuristic mathematical methods for describing the X-ray dispersion, comparing them with the experimental data obtained with Dtl. The predictions of both models are adjusted well to the experimental data. (Author)

  13. Superductile bulk metallic glass

    International Nuclear Information System (INIS)

    Yao, K.F.; Ruan, F.; Yang, Y.Q.; Chen, N.

    2006-01-01

    Usually, monolithic bulk metallic glasses undergo inhomogeneous plastic deformation and exhibit poor ductility (<2%) at room temperature. We report a newly developed Pd-Si binary bulk metallic glass, which exhibits a uniform plastic deformation and a large plastic engineering strain of 82% and a plastic true strain of 170%, together with initial strain hardening, slight strain softening and final strain hardening characteristics. The uniform shear deformation and the ultrahigh plasticity are mainly attributed to strain hardening, which results from the nanoscale inhomogeneity due to liquid phase separation. The formed nanoscale inhomogeneity will hinder, deflect, and bifurcate the propagation of shear bands

  14. Aging in a Structural Glass

    OpenAIRE

    Kob, Walter; Barrat, Jean-Louis

    1998-01-01

    We discuss the relaxation dynamics of a simple structural glass which has been quenched below its glass transition temperature. We demonstrate that time correlation functions show strong aging effects and investigate in what way the fluctuation dissipation theorem is violated.

  15. Foam Glass for Construction Materials

    DEFF Research Database (Denmark)

    Petersen, Rasmus Rosenlund

    2016-01-01

    Foaming is commonly achieved by adding foaming agents such as metal oxides or metal carbonates to glass powder. At elevated temperature, the glass melt becomes viscous and the foaming agents decompose or react to form gas, causing a foamy glass melt. Subsequent cooling to room temperature, result...... in a solid foam glass. The foam glass industry employs a range of different melt precursors and foaming agents. Recycle glass is key melt precursors. Many parameters influence the foaming process and optimising the foaming conditions is very time consuming. The most challenging and attractive goal is to make...... low density foam glass for thermal insulation applications. In this thesis, it is argued that the use of metal carbonates as foaming agents is not suitable for low density foam glass. A reaction mechanism is proposed to justify this result. Furthermore, an in situ method is developed to optimise...

  16. Glass ceilings of professionalisation.

    Science.gov (United States)

    Stott, Dawn L

    2016-04-01

    The term glass ceiling is a political term often used to describe an unbreakable barrier that isnot visible with the human eye, but it keeps minorities from rising up i.e. it is a barrier to minoritygroups, in the past (and sometimes still) for women, that stops them from achieving theirtrue potential.

  17. What Glass Ceiling?

    Science.gov (United States)

    Lynch, Michael; Post, Katherine

    1996-01-01

    A recent study drawing on data from the Census Bureau and the Bureau of Labor Statistics suggests that the wage gap between men and women has virtually disappeared, and that the so-called "glass ceiling" results more from age and qualifications than from explicit discrimination. (SLD)

  18. Metallic glasses: structural models

    International Nuclear Information System (INIS)

    Nassif, E.

    1984-01-01

    The aim of this work is to give a summary of the attempts made up to the present in order to discribe by structural models the atomic arrangement in metallic glasses, showing also why the structure factors and atomic distribution functions cannot be always experimentally determined with a reasonable accuracy. (M.W.O.) [pt

  19. Microchips on glass

    NARCIS (Netherlands)

    Nanver, L.; De Vreede, L.; Keulemans, M.

    2007-01-01

    Microchips on glass. What about a mobile phone that uses a single microchip to receive all the available frequency bands, plus extras such as television, gps, and Internet access? Or, in due time, see-though implants that will monitor your state of health, and equipment that will let you see through

  20. Glass as matter

    DEFF Research Database (Denmark)

    Beim, Anne

    2000-01-01

    Refraiming the Moderns - Substitute Windows and Glass. In general terms, the seminar has contributed to the growing interest in the problems concerning the restoration of Modern Movement architecture. More particularly, it has of course drawn our attention to modern windows, which are increasingly...

  1. Glass ... current issues

    International Nuclear Information System (INIS)

    Wright, A.F.; Dupuy, J.

    1985-01-01

    The objectives of the School were twofold. Firstly to inform participants of actual and developing technological applications of glassy materials in which fundamental science makes a strong contribution, and secondly to bring together scientists from the widely different backgrounds of glass science and technology to promote mutual understanding and collaboration. (orig.)

  2. Stained Glass and Flu

    Centers for Disease Control (CDC) Podcasts

    2017-02-01

    Dr. Robert Webster, an Emeritus member of the Department of Infectious Diseases at St. Jude Children's Research Hospital, discusses his cover art story on stained glass and influenza.  Created: 2/1/2017 by National Center for Emerging and Zoonotic Infectious Diseases (NCEZID).   Date Released: 2/1/2017.

  3. Glasses and nuclear waste vitrification

    International Nuclear Information System (INIS)

    Ojovan, Michael I.

    2012-01-01

    Glass is an amorphous solid material which behaves like an isotropic crystal. Atomic structure of glass lacks long-range order but possesses short and most probably medium range order. Compared to crystalline materials of the same composition glasses are metastable materials however crystallisation processes are kinetically impeded within times which typically exceed the age of universe. The physical and chemical durability of glasses combined with their high tolerance to compositional changes makes glasses irreplaceable when hazardous waste needs immobilisation for safe long-term storage, transportation and consequent disposal. Immobilisation of radioactive waste in glassy materials using vitrification has been used successfully for several decades. Nuclear waste vitrification is attractive because of its flexibility, the large number of elements which can be incorporated in the glass, its high corrosion durability and the reduced volume of the resulting wasteform. Vitrification involves melting of waste materials with glass-forming additives so that the final vitreous product incorporates the waste contaminants in its macro- and micro-structure. Hazardous waste constituents are immobilised either by direct incorporation into the glass structure or by encapsulation when the final glassy material can be in form of a glass composite material. Both borosilicate and phosphate glasses are currently used to immobilise nuclear wastes. In addition to relatively homogeneous glasses novel glass composite materials are used to immobilise problematic waste streams. (author)

  4. Apollo 12 ropy glasses revisited

    Science.gov (United States)

    Wentworth, S. J.; Mckay, D. S.; Lindstrom, D. J.; Basu, A.; Martinez, R. R.; Bogard, D. D.; Garrison, D. H.

    1994-01-01

    We analyzed ropy glasses from Apollo 12 soils 12032 and 12033 by a variety of techniques including SEM/EDX, electron microprobe analysis, INAA, and Ar-39-Ar-40 age dating. The ropy glasses have potassium rare earth elements phosphorous (KREEP)-like compositions different from those of local Apollo 12 mare soils; it is likely that the ropy glasses are of exotic origin. Mixing calculations indicate that the ropy glasses formed from a liquid enriched in KREEP and that the ropy glass liquid also contained a significant amount of mare material. The presence of solar Ar and a trace of regolith-derived glass within the ropy glasses are evidence that the ropy glasses contain a small regolith component. Anorthosite and crystalline breccia (KREEP) clasts occur in some ropy glasses. We also found within these glasses clasts of felsite (fine-grained granitic fragments) very similar in texture and composition to the larger Apollo 12 felsites, which have a Ar-39-Ar-40 degassing age of 800 +/- 15 Ma. Measurements of 39-Ar-40-Ar in 12032 ropy glass indicate that it was degassed at the same time as the large felsite although the ropy glass was not completely degassed. The ropy glasses and felsites, therefore, probably came from the same source. Most early investigators suggested that the Apollo 12 ropy glasses were part of the ejecta deposited at the Apollo 12 site from the Copernicus impact. Our new data reinforce this model. If these ropy glasses are from Copernicus, they provide new clues to the nature of the target material at the Copernicus site, a part of the Moon that has not been sampled directly.

  5. Application of low-cost Gallium Arsenide light-emitting-diodes as kerma dosemeter and fluence monitor for high-energy neutrons

    International Nuclear Information System (INIS)

    Mukherjee, B.; Simrock, S.; Khachan, J.; Rybka, D.; Romaniuk, R.

    2007-01-01

    Displacement damage (DD) caused by fast neutrons in unbiased Gallium Arsenide (GaAs) light emitting diodes (LED) resulted in a reduction of the light output. On the other hand, a similar type of LED irradiated with gamma rays from a 60 Co source up to a dose level in excess of 1.0 kGy (1.0 x 10 5 rad) was found to show no significant drop of the light emission. This phenomenon was used to develop a low cost passive fluence monitor and kinetic energy released per unit mass dosemeter for accelerator-produced neutrons. These LED-dosemeters were used to assess the integrated fluence of photoneutrons, which were contaminated with a strong Bremsstrahlung gamma-background generated by the 730 MeV superconducting electron linac driving the free electron laser in Hamburg (FLASH) at Deutsches Elektronen-Synchrotron. The applications of GaAs LED as a routine neutron fluence monitor and DD precursor for the electronic components located in high-energy accelerator environment are highlighted. (authors)

  6. Glass bead cultivation of fungi

    DEFF Research Database (Denmark)

    Droce, Aida; Sørensen, Jens Laurids; Giese, H.

    2013-01-01

    Production of bioactive compounds and enzymes from filamentous fungi is highly dependent on cultivation conditions. Here we present an easy way to cultivate filamentous fungi on glass beads that allow complete control of nutrient supply. Secondary metabolite production in Fusarium graminearum...... and Fusarium solani cultivated on agar plates, in shaking liquid culture or on glass beads was compared. Agar plate culture and glass bead cultivation yielded comparable results while liquid culture had lower production of secondary metabolites. RNA extraction from glass beads and liquid cultures was easier...... to specific nutrient factors. •Fungal growth on glass beads eases and improves fungal RNA extraction....

  7. Sodium diffusion in boroaluminosilicate glasses

    DEFF Research Database (Denmark)

    Smedskjaer, Morten M.; Zheng, Qiuju; Mauro, John C.

    2011-01-01

    of isothermal sodium diffusion in BAS glasses by ion exchange, inward diffusion, and tracer diffusion experiments. By varying the [SiO2]/[Al2O3] ratio of the glasses, different structural regimes of sodium behavior are accessed. We show that the mobility of the sodium ions decreases with increasing [SiO2]/[Al2O......Understanding the fundamentals of alkali diffusion in boroaluminosilicate (BAS) glasses is of critical importance for advanced glass applications, e.g., the production of chemically strengthened glass covers for personal electronic devices. Here, we investigate the composition dependence...

  8. Low thermal expansion glass ceramics

    CERN Document Server

    1995-01-01

    This book is one of a series reporting on international research and development activities conducted by the Schott group of companies With the series, Schott aims to provide an overview of its activities for scientists, engineers, and managers from all branches of industry worldwide where glasses and glass ceramics are of interest Each volume begins with a chapter providing a general idea of the current problems, results, and trends relating to the subjects treated This volume describes the fundamental principles, the manufacturing process, and applications of low thermal expansion glass ceramics The composition, structure, and stability of polycrystalline materials having a low thermal expansion are described, and it is shown how low thermal expansion glass ceramics can be manufactured from appropriately chosen glass compositions Examples illustrate the formation of this type of glass ceramic by utilizing normal production processes together with controlled crystallization Thus glass ceramics with thermal c...

  9. Fun with singing wine glasses

    Science.gov (United States)

    Boone, Christine; Galloway, Melodie; Ruiz, Michael J.

    2018-05-01

    A fun activity is presented using singing wine glasses for introductory physics students. Students tune a white wine glass and a red wine glass to as many semitones as possible by filling the glasses with the appropriate amounts of water. A smart phone app is used to measure the frequencies of equal-temperament tones. Then plots of frequency against water volume percent are made using a spreadsheet. Students can also play combinations of pitches with several glasses. A video (Ruiz 2018 Video: Singing glasses http://mjtruiz.com/ped/wineglasses/) is provided which includes an excerpt of a beautiful piece written for singing glasses and choir: Stars by Latvian composer Ēriks Ešenvalds.

  10. Bulk metallic glass matrix composites

    International Nuclear Information System (INIS)

    Choi-Yim, H.; Johnson, W.L.

    1997-01-01

    Composites with a bulk metallic glass matrix were synthesized and characterized. This was made possible by the recent development of bulk metallic glasses that exhibit high resistance to crystallization in the undercooled liquid state. In this letter, experimental methods for processing metallic glass composites are introduced. Three different bulk metallic glass forming alloys were used as the matrix materials. Both ceramics and metals were introduced as reinforcement into the metallic glass. The metallic glass matrix remained amorphous after adding up to a 30 vol% fraction of particles or short wires. X-ray diffraction patterns of the composites show only peaks from the second phase particles superimposed on the broad diffuse maxima from the amorphous phase. Optical micrographs reveal uniformly distributed particles in the matrix. The glass transition of the amorphous matrix and the crystallization behavior of the composites were studied by calorimetric methods. copyright 1997 American Institute of Physics

  11. The borosilicate glass for 'PAMELA'

    International Nuclear Information System (INIS)

    Schiewer, E.

    1986-01-01

    The low enriched waste concentrate (LEWC) stored at Mol, Belgium, will be solidified in the vitrification plant 'PAMELA'. An alkali-borosilicate glass was developed by the Hahn-Meitner-Institut, Berlin, which dissolves (11 +- 3)wt% waste oxides while providing sufficient flexibility for changes in the process parameters. The development of the glass labelled SM513LW11 is described. Important properties of the glass melt (viscosity, resistivity, formation of yellow phase) and of the glass (corrosion in aqueous solutions, crystallization) are reported. The corrosion data of this glass are similar to those of other HLW-glasses. Less than five wt% of crystalline material are produced upon cooling of large glass blocks. Crystallization does not affect the chemical durability. (Auth.)

  12. Production of glass or glass-ceramic to metal seals with the application of pressure

    Science.gov (United States)

    Kelly, Michael D.; Kramer, Daniel P.

    1987-11-10

    In a process for preparing a glass or glass-ceramic to metal seal comprising contacting the glass with the metal and heat-treating the glass and metal under conditions whereby the glass to metal seal is effected and, optionally, the glass is converted to a glass-ceramic, an improvement comprises carrying out the heat-treating step using hot isostatic pressing.

  13. Characterisation of a Personal TL Photon Dosemeter Based on Two LiF(Mg,Cu,P) Detectors in Terms of Hp(0.07,alpha) and Hp(10,alpha)

    International Nuclear Information System (INIS)

    Fantuzzi, E.; Monteventi, F.; Sermenghi, I.; Uleri, G.

    1999-01-01

    A study was undertaken to evaluate the response of the ENEA Photon Personal Dosemeter, slightly modified in design, in terms of H p (0.07, α) and H p (10, α). A filtration of 20 and 270 mg.cm -2 respectively for the two LiF(Mg,Cu,P) detectors employed was adopted according to a preliminary analytical simulation. The new dosemeter can measure both H p (0.07, α) with a maximum uncertainty of ±4% in the range from 10 to 200 keV and H p (10, α) with a maximum uncertainty of ±15% in the range from 10 keV to 1.25 MeV, using the detector responses together with a correction function with respect to their ratio. Moreover, tests were performed to evaluate the dosemeter angular response (0 deg., 20 deg., 40 deg., and 60 deg.) obtaining good results according to international recommendations. All irradiation tests were performed at SSL of ENEA Institute for Radiation Protection in Bologna using the ISO water phantom (30 x 30 x 15 cm 3 ) and standard ISO filtered X ray beams as well as 137 Cs and 60 Co sources. This work represents a preliminary type test of the ENEA photon personal dosemeter and allows its introduction in routine dosimetry practice in accordance with the ICRU reference quantities. (author)

  14. Valuation of a CD-96 reader dedicated to quick read-out and archivisation of foil dosemeter absorbance; Ocena czytnika CD-96 przeznaczonego do szybkiego mierzenia absorbancji tasmowych dozymetrow foliowych i archiwizowania wynikow pomiaru

    Energy Technology Data Exchange (ETDEWEB)

    Malicki, W.; Bryl-Sandelewska, T.; Stuglik, Z.

    1997-12-31

    A check of the useful parameters of CD-96 reader is presented. The reader was constructed in the Department of Radioisotope Instruments and Methods of the INCT and dedicated to quick read-out of the foil dosemeter absorbances and for their archivisation. (author). 9 refs, 9 figs.

  15. Effect of some parameters in the response of the Perspex 3042, Lot L amber dosemeters; Efectos de algunos parametros en la respuesta de los dosimetros ambar Perspex 3042, Lote L

    Energy Technology Data Exchange (ETDEWEB)

    Prieto M, E.F.; Barrera G, G. [Centro de Aplicaciones Tecnologicas y Desarrollo Nuclear (CEADEN). Calle 30, No. 502, esq. 5ta. Avenida, Playa, Ciudad de La Habana (Cuba)]. e-mail: efprieto@ceaden.edu.cu

    2004-07-01

    The answer of the dosimetric systems is affected by several factors, for what should know as these factors they influence in each one of the different dosimetric systems and by this way to minimize its effect in the value of the absorbed dose and to obtain exact dose values. One of the dosimetric systems more used in the high dose dosimetry like routine dosemeter for the control of the irradiation process are the Perspex dosemeters, for their speed in the obtaining the information, their easy manipulation and the precision that they present. To this dosemeters group they belong the same as the Red and Clear the Amber, which are adequate for the measurement of the radiation dose in the range of high doses. The objective of the present work is to obtain the calibration curves of the dosemeters Amber Perspex 3042, Lot L under our work conditions, like they are the irradiation temperatures and of storage and to know the influence of the rate dose in the value of the absorbed dose for different measurement wavelengths, as well as, the relationship among the one post-irradiation time and the specific absorbance value induced in function of the absorbed dose. (Author)

  16. Glasses for Mali

    CERN Multimedia

    PH Department

    2008-01-01

    We are collecting old pairs of glasses to take out to Mali, where they can be re-used by people there. The price for a pair of glasses can often exceed 3 months salary, so they are prohibitively expensive for many people. If you have any old spectacles you can donate, please put them in the special box in the ATLAS secretariat, Bldg.40-4-D01 before the Christmas closure on 19 December so we can take them with us when we leave for Africa at the end of the month. (more details in ATLAS e-news edition of 29 September 2008: http://atlas-service-enews.web.cern.ch/atlas-service-enews/news/news_mali.php) many thanks! Katharine Leney co-driver of the ATLAS car on the Charity Run to Mali

  17. Glass manufacturing through induction

    International Nuclear Information System (INIS)

    Boen, R.; Paya, B.; Roscini, M.; Fautrelle, Y.; Tuaz, F.; Delage, D.

    1991-01-01

    Oxides and glasses are electrical and thermal insulators, but show the characteristic of being weakly conductors of electricity when they are melt. It is then possible to heat them through HF induction. This interesting property allows the development of a melting process in cold crucible induction furnace. The process is being studied and developed by a consortium made up of CFEI, CEA Marcoule, ELECTRICITE DE FRANCE and MADYLAM laboratory. The studies include 2 parts: a) One experimental part to develop the technology and research for satisfying configurations, through a small size platform (10 to 30 kg/h). The long run continuous pouring melting tests made on different kinds of glass allow to go-on with industrial range units. b) One theoretical part to understand the magneto-thermo-hydraulic phenomenon hardly in relation with the heavy dependence of the physical characteristics (electrical and heat conductivities, viscosity) according to temperature. 6 refs., 4 figs [fr

  18. Glass matrix armor

    International Nuclear Information System (INIS)

    Calkins, N.C.

    1991-01-01

    This patent describes an armor system which utilizes glass. A plurality of constraint cells are mounted on a surface of a substrate, which is metal armor plate or a similar tough material, such that the cells almost completely cover the surface of the substrate. Each constraint cell has a projectile receiving wall parallel to the substrate surface and has sides which are perpendicular to and surround the perimeter of the receiving wall. The cells are mounted such that, in one embodiment, the substrate surface serves as a sixth side or closure for each cell. Each cell has inside of it a plate, termed the front plate, which is parallel to and in contact with substantially all of the insides surface of the receiving wall. The balance of each cell is completely filled with a projectile-abrading material consisting of glass and a ceramic material and, in certain embodiments, a polymeric material

  19. Breaking the glass ceiling.

    Science.gov (United States)

    Lazarus, A

    1997-03-01

    The glass ceiling is a form of organizational bias and discrimination that prevents qualified professionals from achieving positions of top governance and leadership. This article examines glass ceiling barriers that keep physicians from the upper reaches of management. While these factors apply mainly to women and minority physicians in academia, and are attributable to sexual harassment and discrimination, physicians as a class are frequently denied executive management positions. Such denial results from inadequate preparation for a career in health care administration. Important issues in the professional development of physician executives include mentoring, training and education, administrative experience, and cultural and personality factors. All of those must be considered when making the transition from medicine to management.

  20. HLW immobilization in glass

    International Nuclear Information System (INIS)

    Leroy, P.; Jacquet-Francillon, N.; Runge, S.

    1992-01-01

    The immobilization of High Level Waste in glass in France is a long history which started as early as in the 1950's. More than 30 years of Research and Development have been invested in that field. Two industrial facilities are operating (AVM and R7) and a third one (T7), under cold testing, is planned to start active operation in the mid-92. While vitrification has been demonstrated to be an industrially mastered process, the question of the quality of the final waste product, i.e. the HLW glass, must be addressed. The scope of the present paper is to focus on the latter point from both standpoints of the R and D and of the industrial reality

  1. Nuclear traces in glass

    International Nuclear Information System (INIS)

    Segovia A, M. de N.

    1978-01-01

    The charged particles produce, in dielectric materials, physical and chemical effects which make evident the damaged zone along the trajectory of the particle. This damaged zone is known as the latent trace. The latent traces can be enlarged by an etching of the detector material. This treatment attacks preferently the zones of the material where the charged particles have penetrated, producing concavities which can be observed through a low magnification optical microscope. These concavities are known as developed traces. In this work we describe the glass characteristics as a detector of the fission fragments traces. In the first chapter we present a summary of the existing basic theories to explain the formation of traces in solids. In the second chapter we describe the etching method used for the traces development. In the following chapters we determine some chatacteristics of the traces formed on the glass, such as: the development optimum time; the diameter variation of the traces and their density according to the temperature variation of the detector; the glass response to a radiation more penetrating than that of the fission fragments; the distribution of the developed traces and the existing relation between this ditribution and the fission fragments of 252 Cf energies. The method which has been used is simple and cheap and can be utilized in laboratories whose resources are limited. The commercial glass which has been employed allows the registration of the fission fragments and subsequently the realization of experiments which involve the counting of the traces as well as the identification of particles. (author)

  2. Amorphous gauge glass theory

    International Nuclear Information System (INIS)

    Nielsen, H.B.; Bennett, D.L.

    1987-08-01

    Assuming that a lattice gauge theory describes a fundamental attribute of Nature, it should be pointed out that such a theory in the form of a gauge glass is a weaker assumption than a regular lattice model in as much as it is not constrained by the imposition of translational invariance; translational invariance is, however, recovered approximately in the long wavelength or continuum limit. (orig./WL)

  3. Polyamorphism in metalic glass.

    Energy Technology Data Exchange (ETDEWEB)

    Sheng, H. W.; Liu, H. Z.; Cheng, Y. Q.; Wen, J.; Lee, P.L.; Luo, W.K.; Shastri, S.D.; Ma, E.; X-Ray Science Division; Johns Hopkins Univ.; Chinese Academy of Sciences

    2007-03-01

    A metal, or an alloy, can often exist in more than one crystal structure. The face-centered-cubic and body-centered-cubic forms of iron (or steel) are a familiar example of such polymorphism. When metallic materials are made in the amorphous form, is a parallel 'polyamorphism' possible? So far, polyamorphic phase transitions in the glassy state have been observed only in glasses involving directional and open (such as tetrahedral) coordination environments. Here, we report an in situ X-ray diffraction observation of a pressure-induced transition between two distinct amorphous polymorphs in a Ce{sub 55}Al{sub 45} metallic glass. The large density difference observed between the two polyamorphs is attributed to their different electronic and atomic structures, in particular the bond shortening revealed by ab initio modeling of the effects of f-electron delocalization. This discovery offers a new perspective of the amorphous state of metals, and has implications for understanding the structure, evolution and properties of metallic glasses and related liquids. Our work also opens a new avenue towards technologically useful amorphous alloys that are compositionally identical but with different thermodynamic, functional and rheological properties due to different bonding and structural characteristics.

  4. Diffusion in glass

    Energy Technology Data Exchange (ETDEWEB)

    Mubarak, A S

    1991-12-31

    Rutherford backscattering spectromertry technique (RBS) was used to characterize and investigate the depth distribution profiles of Ca-impurities of Ca-doped soda-time glass. The purposely added Ca-impurities were introduced inti the glass matrix by a normal ion exchange diffusion process. The measurements and analysis were performed using 2 MeV {sup 2}He{sup +} ions supplied from the University of Jordan Van de Graff acceierator (JOVAG). The normalized concetration versus depth profile distributions for the Ca-imourities were determined, both theoretically and experimentally. The theoretical treatment was carried out by setting up and soiving the diffusion equation under the conditions of the experiment. The resulting profiles are characterized by a compiementary error function. the theoretical treeatment was extended to include the various methods of enhancing the diffusion process, e.g. using an electric field. The diffusion coefficient, assumed constant, of the Ca-impurities exchanged in the soda-lime glass was determined to be 1.23 x 10{sup 13} cm{sup 2}/s. A comparison between theoretically and experimentally determined profiles is made and commented at, where several conclusions are drawn and suggestions for future work are mentioned. (author). 38 refs., 21 figs., 10 Tabs.

  5. Radiation shielding glass

    International Nuclear Information System (INIS)

    Kido, Kazuhiro; Ueda, Hajime.

    1997-01-01

    It was found that a glass composition comprising, as essential ingredients, SiO 2 , PbO, Gd 2 O 3 and alkali metal oxides can provide a shielding performance against electromagnetic waves, charged particles and neutrons. The present invention provides radiation shielding glass containing at least from 16 to 46wt% of SiO 2 , from 47 to 75wt% of PbO, from 1 to 10wt% of Gd 2 O 3 , from 0 to 3wt% of Li 2 O, from 0 to 7wt% of Na 2 O, from 0 to 7wt% of K 2 O provided that Li 2 O + Na 2 O + K 2 O is from 1 to 10wt%, B 2 O 3 is from 0 to 10wt%, CeO 2 is from 0 to 3wt%, As 2 O 3 is from 0 to 1wt% and Sb 2 O 3 is from 0 to 1wt%. Since the glass can shield electromagnetic waves, charged particles and neutrons simultaneously, radiation shielding windows can be designed and manufactured at a reduced thickness and by less constitutional numbers in a circumstance where they are present altogether. (T.M.)

  6. Helium behaviour in nuclear glasses

    International Nuclear Information System (INIS)

    Fares, T.

    2011-01-01

    The present thesis focuses on the study of helium behavior in R7T7 nuclear waste glass. Helium is generated by the minor actinides alpha decays incorporated in the glass matrix. Therefore, four types of materials were used in this work. These are non radioactive R7T7 glasses saturated with helium under pressure, glasses implanted with 3 He + ions, glasses doped with curium and glasses irradiated in nuclear reactor. The study of helium solubility in saturated R7T7 glass has shown that helium atoms are inserted in the glass free volume. The results yielded a solubility of about 10 16 at. cm -3 atm. -1 . The incorporation limit of helium in this type of glass has been determined; its value amounted to about 2*10 21 at. cm -3 , corresponding to 2.5 at.%. Diffusion studies have shown that the helium migration is controlled by the single population dissolved in the glass free volume. An ideal diffusion model was used to simulate the helium release data which allowed to determine diffusion coefficients obeying to the following Arrhenius law: D = D 0 exp(-E a /kBT), where D 0 = 2.2*10 -2 and 5.4*10 -3 cm 2 s -1 and E a = 0.61 eV for the helium saturated and the curium doped glass respectively. These results reflect a thermally activated diffusion mechanism which seems to be not influenced by the glass radiation damage and helium concentrations studied in the present work (up to 8*10 19 at. g -1 , corresponding to 0.1 at.%). Characterizations of the macroscopic, structural and microstructural properties of glasses irradiated in nuclear reactor did not reveal any impact associated with the presence of helium at high concentrations. The observed modifications i.e. a swelling of 0.7 %, a decrease in hardness by 38 %, an increase between 8 and 34 % of the fracture toughness and a stabilization of the glass structure under irradiation, were attributed to the glass nuclear damage induced by the irradiation in reactor. Characterizations by SEM and TEM of R7T7 glasses implanted

  7. Laboratory testing of LITCO glasses

    International Nuclear Information System (INIS)

    Ellison, A.; Wolf, S.; Buck, E.; Luo, J.S.; Dietz, N.; Bates, J.K.; Ebert, W.L.

    1995-01-01

    The purpose of this program is to measure, the intermediate and long-term durability of glasses developed by Lockheed Idaho Technology Co. (LITCO) for the immobilization of calcined radioactive wastes. The objective is to use accelerated corrosion tests as an aid in developing durable waste form compositions. This is a report of tests performed on two LITCO glass compositions, Formula 127 and Formula 532. The main avenue for release of radionuclides into the environment in a geologic repository is the reaction of a waste glass with ground water, which alters the glass and releases its components into solution. These stages in glass corrosion are analyzed by using accelerated laboratory tests in which the ratio of sample surface area to solution volume, SA/V, is varied. At low SA/V, the solution concentrations of glass corrosion products remain low and the reaction approaches the forward rate. At higher SA/V the solution approaches saturation levels for glass corrosion products. At very high SA/V the solution is rapidly saturated in glass corrosion products and secondary crystalline phases precipitate. Tests at very high SA/V provide information about the composition of the solution at saturation or, when no solution is recovered, the identities and the order of appearance of secondary crystalline phases. Tests were applied to Formula 127 and Formula 532 glasses to provide information about the interim and long-term stages in glass corrosion

  8. Glass containing radioactive nuclear waste

    International Nuclear Information System (INIS)

    Boatner, L.A.; Sales, B.C.

    1985-01-01

    Lead-iron phosphate glasses containing a high level of Fe 2 O 3 for use as a storage medium for high-level-radioactive nuclear waste. By combining lead-iron phosphate glass with various types of simulated high-level nuclear waste, a highly corrosion resistant, homogeneous, easily processed glass can be formed. For corroding solutions at 90 C, with solution pH values in the range between 5 and 9, the corrosion rate of the lead-iron phosphate nuclear waste glass is at least 10 2 to 10 3 times lower than the corrosion rate of a comparable borosilicate nuclear waste glass. The presence of Fe 2 O 3 in forming the lead-iron phosphate glass is critical. Lead-iron phosphate nuclear waste glass can be prepared at temperatures as low as 800 C, since they exhibit very low melt viscosities in the 800 to 1050 C temperature range. These waste-loaded glasses do not readily devitrify at temperatures as high as 550 C and are not adversely affected by large doses of gamma radiation in H 2 O at 135 C. The lead-iron phosphate waste glasses can be prepared with minimal modification of the technology developed for processing borosilicate glass nuclear waste forms. (author)

  9. Transferability of glass lens molding

    Science.gov (United States)

    Katsuki, Masahide

    2006-02-01

    Sphere lenses have been used for long time. But it is well known that sphere lenses theoretically have spherical aberration, coma and so on. And, aspheric lenses attract attention recently. Plastic lenses are molded easily with injection machines, and are relatively low cost. They are suitable for mass production. On the other hand, glass lenses have several excellent features such as high refractive index, heat resistance and so on. Many aspheric glass lenses came to be used for the latest digital camera and mobile phone camera module. It is very difficult to produce aspheric glass lenses by conventional process of curve generating and polishing. For the solution of this problem, Glass Molding Machine was developed and is spreading through the market. High precision mold is necessary to mold glass lenses with Glass Molding Machine. The mold core is ground or turned by high precision NC aspheric generator. To obtain higher transferability of the mold core, the function of the molding machine and the conditions of molding are very important. But because of high molding temperature, there are factors of thermal expansion and contraction of the mold and glass material. And it is hard to avoid the factors. In this session, I introduce following items. [1] Technology of glass molding and the machine is introduced. [2] The transferability of glass molding is analyzed with some data of glass lenses molded. [3] Compensation of molding shape error is discussed with examples.

  10. Analytical Plan for Roman Glasses

    Energy Technology Data Exchange (ETDEWEB)

    Strachan, Denis M.; Buck, Edgar C.; Mueller, Karl T.; Schwantes, Jon M.; Olszta, Matthew J.; Thevuthasan, Suntharampillai; Heeren, Ronald M.

    2011-01-01

    Roman glasses that have been in the sea or underground for about 1800 years can serve as the independent “experiment” that is needed for validation of codes and models that are used in performance assessment. Two sets of Roman-era glasses have been obtained for this purpose. One set comes from the sunken vessel the Iulia Felix; the second from recently excavated glasses from a Roman villa in Aquileia, Italy. The specimens contain glass artifacts and attached sediment or soil. In the case of the Iulia Felix glasses quite a lot of analytical work has been completed at the University of Padova, but from an archaeological perspective. The glasses from Aquileia have not been so carefully analyzed, but they are similar to other Roman glasses. Both glass and sediment or soil need to be analyzed and are the subject of this analytical plan. The glasses need to be analyzed with the goal of validating the model used to describe glass dissolution. The sediment and soil need to be analyzed to determine the profile of elements released from the glass. This latter need represents a significant analytical challenge because of the trace quantities that need to be analyzed. Both pieces of information will yield important information useful in the validation of the glass dissolution model and the chemical transport code(s) used to determine the migration of elements once released from the glass. In this plan, we outline the analytical techniques that should be useful in obtaining the needed information and suggest a useful starting point for this analytical effort.

  11. Bioactive glass in tissue engineering

    Science.gov (United States)

    Rahaman, Mohamed N.; Day, Delbert E.; Bal, B. Sonny; Fu, Qiang; Jung, Steven B.; Bonewald, Lynda F.; Tomsia, Antoni P.

    2011-01-01

    This review focuses on recent advances in the development and use of bioactive glass for tissue engineering applications. Despite its inherent brittleness, bioactive glass has several appealing characteristics as a scaffold material for bone tissue engineering. New bioactive glasses based on borate and borosilicate compositions have shown the ability to enhance new bone formation when compared to silicate bioactive glass. Borate-based bioactive glasses also have controllable degradation rates, so the degradation of the bioactive glass implant can be more closely matched to the rate of new bone formation. Bioactive glasses can be doped with trace quantities of elements such as Cu, Zn and Sr, which are known to be beneficial for healthy bone growth. In addition to the new bioactive glasses, recent advances in biomaterials processing have resulted in the creation of scaffold architectures with a range of mechanical properties suitable for the substitution of loaded as well as non-loaded bone. While bioactive glass has been extensively investigated for bone repair, there has been relatively little research on the application of bioactive glass to the repair of soft tissues. However, recent work has shown the ability of bioactive glass to promote angiogenesis, which is critical to numerous applications in tissue regeneration, such as neovascularization for bone regeneration and the healing of soft tissue wounds. Bioactive glass has also been shown to enhance neocartilage formation during in vitro culture of chondrocyte-seeded hydrogels, and to serve as a subchondral substrate for tissue-engineered osteochondral constructs. Methods used to manipulate the structure and performance of bioactive glass in these tissue engineering applications are analyzed. PMID:21421084

  12. NEW ERBIUM DOPED ANTIMONY GLASSES FOR LASER AND GLASS AMPLIFICATION

    Directory of Open Access Journals (Sweden)

    B. Tioua

    2015-07-01

    Full Text Available Because of the special spectroscopic properties of the rare earth ions, rare earth doped glasses are widely used in bulk and fiber lasers or amplifiers. The modelling of lasers and searching for new laser transitions require a precise knowledge of the spectroscopic properties of rare earth ions in different host glasses. In this poster will offer new doped erbium glasses synthesized in silicate crucibles were obtained in the combination Sb2O3-WO3-Na2O. Several properties are measured and correlated with glass compositions. The absorption spectral studies have been performed for erbium doped glasses. The intensities of various absorption bands of the doped glasses are measured and the Judd-Ofelt parameters have been computed. From the theory of Judd-Ofelt, various radiative properties, such as transition probability, branching ratio and radiative life time for various emission levels of these doped glasses have been determined and reported. These results confirm the ability of antimony glasses for glass amplification.

  13. Mechanical failure and glass transition in metallic glasses

    International Nuclear Information System (INIS)

    Egami, T.

    2011-01-01

    Research highlights: → We review the recent results of molecular dynamics simulations on metallic glasses. → They show the equivalence of mechanical failure and glass transition. → We discuss the microscopic mechanism behind this equivalence. → We show that the density of defects in metallic glasses is as high as a quarter. → Our concepts about the defect state in glasses need to be changed. - Abstract: The current majority view on the phenomenon of mechanical failure in metallic glasses appears to be that it is caused by the activity of some structural defects, such as free-volumes or shear transformation zones, and the concentration of such defects is small, only of the order of 1%. However, the recent results compel us to revise this view. Through molecular dynamics simulation it has been shown that mechanical failure is the stress-induced glass transition. According to our theory the concentration of the liquid-like sites (defects) is well over 20% at the glass transition. We suggest that the defect concentration in metallic glasses is actually very high, and percolation of such defects causes atomic avalanche and mechanical failure. In this article we discuss the glass transition, mechanical failure and viscosity from such a point of view.

  14. Influence of Glass Property Restrictions on Hanford HLW Glass Volume

    International Nuclear Information System (INIS)

    Kim, Dong-Sang; Vienna, John D.

    2001-01-01

    A systematic evaluation of Hanford High-Level Waste (HLW) loading in alkali-alumino-borosilicate glasses was performed. The waste feed compositions used were obtained from current tank waste composition estimates, Hanford's baseline retrieval sequence, and pretreatment processes. The waste feeds were sorted into groups of like composition by cluster analysis. Glass composition optimization was performed on each cluster to meet property and composition constraints while maximizing waste loading. Glass properties were estimated using property models developed for Hanford HLW glasses. The impacts of many constraints on the volume of HLW glass to be produced at Hanford were evaluated. The liquidus temperature, melting temperature, chromium concentration, formation of multiple phases on cooling, and product consistency test response requirements for the glass were varied one- or many-at-a-time and the resultant glass volume was calculated. This study shows clearly that the allowance of crystalline phases in the glass melter can significantly decrease the volume of HLW glass to be produced at Hanford.

  15. Analysis of glass fibre sizing

    DEFF Research Database (Denmark)

    Petersen, Helga Nørgaard; Kusano, Yukihiro; Brøndsted, Povl

    2014-01-01

    Glass fibre reinforced polymer composites are widely used for industrial and engineering applications which include construction, aerospace, automotive and wind energy industry. During the manufacturing glass fibres, they are surface-treated with an aqueous solution. This process and the treated...... surfaces are called sizing. The sizing influences the properties of the interface between fibres and a matrix, and subsequently affects mechanical properties of composites. In this work the sizing of commercially available glass fibres was analysed so as to study the composition and chemical structures....... Soxhlet extraction was used to extract components of the sizing from the glass fibres. The glass fibres, their extracts and coated glass plates were analysed by Thermo-Gravimetric Analysis combined with a mass spectrometer (TGA-MS), and Attenuated Total Reflectance Fourier Transform Infrared (ATR...

  16. Low Thermal Expansion Glass Ceramics

    CERN Document Server

    Bach, Hans

    2005-01-01

    This book appears in the authoritative series reporting the international research and development activities conducted by the Schott group of companies. This series provides an overview of Schott's activities for scientists, engineers, and managers from all branches of industry worldwide in which glasses and glass ceramics are of interest. Each volume begins with a chapter providing a general idea of the current problems, results, and trends relating to the subjects treated. This new extended edition describes the fundamental principles, the manufacturing process, and applications of low thermal expansion glass ceramics. The composition, structure, and stability of polycrystalline materials having a low thermal expansion are described, and it is shown how low thermal expansion glass ceramics can be manufactured from appropriately chosen glass compositions. Examples illustrate the formation of this type of glass ceramic by utilizing normal production processes together with controlled crystallization. Thus g...

  17. Complexity of Curved Glass Structures

    Science.gov (United States)

    Kosić, T.; Svetel, I.; Cekić, Z.

    2017-11-01

    Despite the increasing number of research on the architectural structures of curvilinear forms and technological and practical improvement of the glass production observed over recent years, there is still a lack of comprehensive codes and standards, recommendations and experience data linked to real-life curved glass structures applications regarding design, manufacture, use, performance and economy. However, more and more complex buildings and structures with the large areas of glass envelope geometrically complex shape are built every year. The aim of the presented research is to collect data on the existing design philosophy on curved glass structure cases. The investigation includes a survey about how architects and engineers deal with different design aspects of curved glass structures with a special focus on the design and construction process, glass types and structural and fixing systems. The current paper gives a brief overview of the survey findings.

  18. Electronic structure of metallic glasses

    International Nuclear Information System (INIS)

    Oelhafen, P.; Lapka, R.; Gubler, U.; Krieg, J.; DasGupta, A.; Guentherodt, H.J.; Mizoguchi, T.; Hague, C.; Kuebler, J.; Nagel, S.R.

    1981-01-01

    This paper is organized in six sections and deals with (1) the glassy transition metal alloys, their d-band structure, the d-band shifts on alloying and their relation to the alloy heat of formation (ΔH) and the glass forming ability, (2) the glass to crystal phase transition viewed by valence band spectroscopy, (3) band structure calculations, (4) metallic glasses prepared by laser glazing, (5) glassy normal metal alloys, and (6) glassy hydrides

  19. PLZT capacitor on glass substrate

    Science.gov (United States)

    Fairchild, M. Ray; Taylor, Ralph S.; Berlin, Carl W.; Wong, Celine W. K.; Ma, Beihai; Balachandran, Uthamalingam

    2016-01-05

    A lead-lanthanum-zirconium-titanate (PLZT) capacitor on a substrate formed of glass. The first metallization layer is deposited on a top side of the substrate to form a first electrode. The dielectric layer of PLZT is deposited over the first metallization layer. The second metallization layer deposited over the dielectric layer to form a second electrode. The glass substrate is advantageous as glass is compatible with an annealing process used to form the capacitor.

  20. Glass corrosion in natural environments

    Science.gov (United States)

    Thorpe, Arthur N.; Barkatt, Aaron

    1992-01-01

    Experiments carried out during the progress period are summarized. Experiments carried out involving glass samples exposed to solutions of Tris have shown the appearance of 'spikes' upon monitoring glass dissolution as a function of time. The periodic 'spikes' observed in Tris-based media were interpreted in terms of cracking due to excessive stress in the surface region of the glass. Studies of the interactions of silicate glasses with metal ions in buffered media were extended to systems containing Al. Caps buffer was used to establish the pH. The procedures used are described and the results are given. Preliminary studies were initiated as to the feasibility of adding a slowly dissolving solid compound of the additive to the glass-water system to maintain a supply of dissolved additive. It appears that several magnesium compounds have a suitable combination of solubility and affinity towards silicate glass surfaces to have a pronounced retarding effect on the extraction of uranium from the glass. These preliminary findings raise the possibility that introducing a magnesium source into geologic repositories for nuclear waste glass in the form of a sparingly soluble Mg-based backfill material may cause a substantial reduction in the extent of long-term glass corrosion. The studies described also provide mechanistic understanding of the roles of various metal solutes in the leachant. Such understanding forms the basis for developing long-term predictions of nuclear waste glass durability under repository conditions. From what is known about natural highly reduced glasses such as tektites, it is clear that iron is dissolved as ferrous iron with little or no ferric iron. The reducing conditions were high enough to cause metallic iron to exsolve out of the glass in the form of submicroscopic spherules. As the nuclear waste glass is much less reduced, a study was initiated on other natural glasses in addition to the nuclear waste glass. Extensive measurements were

  1. Crystallization of copper metaphosphate glass

    Science.gov (United States)

    Bae, Byeong-Soo; Weinberg, Michael C.

    1993-01-01

    The effect of the valence state of copper in copper metaphosphate glass on the crystallization behavior and glass transition temperature has been investigated. The crystallization of copper metaphosphate is initiated from the surface and its main crystalline phase is copper metaphosphate (Cu(PO)3),independent of the (Cu sup 2+)/(Cu(total)). However, the crystal morphology, the relative crystallization rates, and their temperature dependences are affected by the (Cu sup 2+)/(Cu (total)) ratio in the glass. On the other hand, the totally oxidized glass crystallizes from all over the surface. The relative crystallization rate of the reduced glass to the totally oxidized glass is large at low temperature, but small at high temperature. The glass transition temperature of the glass increases as the (Cu sup 2+)/(Cu(total)) ratio is raised. It is also found that the atmosphere used during heat treatment does not influence the crystallization of the reduced glass, except for the formation of a very thin CuO surface layer when heated in air.

  2. Fabrication of Radiation Shielding Glass

    International Nuclear Information System (INIS)

    Tavichai, Nattaya; Pormsean, Suriyont; Dararutana, Pisutti; Sirikulrat, Narin

    2003-06-01

    In this work, lead glass doped with 50%, 55%,60%, 65%, and 70% w/w Pb 3 O 4 . After that, glass mixtures were melt at 1,250οC with 4 hours soaking time. Molten glass was shaped by mould casting technique then annealed at 700οC and cooled down to room temperature. It was found that the glass with 60%w/w Pb 3 O 4 show maximum absorption coefficient of about 0.383 cm -1 with I-131 at energy 364 keV. The observed refractive indices of the samples range between 1.5908 to 1.5922

  3. Compositional threshold for Nuclear Waste Glass Durability

    International Nuclear Information System (INIS)

    Kruger, Albert A.; Farooqi, Rahmatullah; Hrma, Pavel R.

    2013-01-01

    Within the composition space of glasses, a distinct threshold appears to exist that separates 'good' glasses, i.e., those which are sufficiently durable, from 'bad' glasses of a low durability. The objective of our research is to clarify the origin of this threshold by exploring the relationship between glass composition, glass structure and chemical durability around the threshold region

  4. Quality control of dosemeters

    International Nuclear Information System (INIS)

    Mendes, L.

    1984-01-01

    Nuclear medicine laboratories are required to assay samples of radioactivity to be administered to patients. Almost universally, these assays are acomplished by use of a well ionization chamber isotope calibrator. The Instituto de Radioprotecao e Dosimetria (Institute for Radiological Protection and Dosimetry) of the Comissao Nacional de Energia Nuclear (National Commission for Nuclear Energy) is carrying out a National Quality Control Programme in Nuclear Medicine, supported by the International Atomic Energy Agency. The assessment of the current needs and practices of quality control in the entire country of Brazil includes Dose Calibrators and Scintilation Cameras, but this manual is restricted to the former. Quality Control Procedures for these Instruments are described in this document together with specific recommendations and assessment of its accuracy. (Author) [pt

  5. HSP as bio dosemeters

    International Nuclear Information System (INIS)

    Manzanares A, E.; Vega C, H.R.

    2005-01-01

    A review of the more important passages for the field of the radiological protection, from the discovery, beginnings of the utilization of the radiations emitting, passing to the legislation proposals and the transformations that had been suffer to establish the international standards of radiological protection. The paradigms on the effects and chronologically the emanated discoveries of the cellular research and the measurement of cellular products in the species and the diverse alive beings making emphasis in evaluating the expression of the heat-shock proteins caused by low doses of gamma radiation, these are used as radiation bio monitors and of other agents that cause cellular stress and lastly a prospective of the future of the radiobiology. (Author)

  6. Proposals for the type tests criteria and calibration conditions of passive eye lens dosemeters to be used in interventional cardiology and radiology workplaces

    International Nuclear Information System (INIS)

    Bordy, J.M.; Daures, J.; Denozière, M.; Gualdrini, G.; Ginjaume, M.; Carinou, E.; Vanhavere, F.

    2011-01-01

    The paper is aimed at making a proposal for the type test and calibration of eye lens passive dosemeters especially used in the interventional cardiology/radiology (IC/IR). Starting from the only existing standard dealing with eye lens dosimetry using TLDs (), parameters such as, detection threshold, energy and angle dependence of response criteria have been reviewed and it has been tried to harmonise them as much as possible with the IEC 62387 requirements, taking into account the particular use at IC/IR workplaces. Conversion coefficients from air kerma to dose equivalent at 3 mm depth for RQR and ISO radiation qualities, employed for type test and calibration purposes, have been calculated in a new phantom introduced within the ORAMED (Optimization of RAdiation protection for MEDical staff) project. This phantom is more representative of the head so that the estimation of H lens by H p (3) is more accurate.

  7. Restorative Glass : Reversible, discreet restoration using structural glass components

    NARCIS (Netherlands)

    Oikonomopoulou, F.; Bristogianni, T.; Barou, L.; van Hees, R.P.J.; Nijsse, R.; Veer, F.A.; Henk, Schellen; van Schijndel, Jos

    2016-01-01

    The application of structural glass as the principal material in restoration and conservation practices is a distinguishable, yet discreet approach. The transparency of glass allows the simultaneous perception of the monument at both its original and present condition, preserving its historical and

  8. New Erbium Doped Antimony Glasses for Laser and Glass ...

    African Journals Online (AJOL)

    Because of the special spectroscopic properties of the rare earth ions, rare earth doped glasses are widely used in bulk and fiber lasers or amplifiers. The modelling of lasers and searching for new laser transitions require a precise knowledge of the spectroscopic properties of rare earth ions in different host glasses.

  9. The glass sphinx: a massive stacked glass structure

    NARCIS (Netherlands)

    Bos, F.P.; Heijden, van der T.; Schreurs, P.; Bos, F.; Louter, C.; Nijsse, R.; Veer, F.

    The refurbishment of the Meuse river boulevard in Venlo instigated Scheuten Glass to donate a giant-sized, 6 metre high version of the stacked glass statue the Sphinx, which had originally been made as a 80 cm sculpture to commemorate the city's 650th anniversary back in 1993. Many hurdles had to be

  10. Structural Glass Beams with Embedded Glass Fibre Reinforcement

    NARCIS (Netherlands)

    Louter, P.C.; Leung, Calvin; Kolstein, M.H.; Vambersky, J.N.J.A.; Bos, Freek; Louter, Pieter Christiaan; Veer, Fred

    2010-01-01

    This paper investigates the possibilities of pultruded glass fibre rods as embedded reinforcement in SentryGlas (SG) laminated glass beams. To do so, a series of pullout tests, to investigate the bond strength of the rods to the laminate, and a series of beam tests, to investigate the post-breakage

  11. Glass ceramic fibres

    International Nuclear Information System (INIS)

    Blaschek, O.; Paulitsch, P.

    1983-01-01

    As the correlation between mineralogical phase and chemical composition influences the type of application at different high temperatures, we studied the mineralogical phases of nine crystal glass fibres of the temperature ranges 1 150 degrees Celsius (Type 1), 1 400 degrees Celsius (Type 2) and 1 500 degrees Celsius (Type 3) at various high temperatures. The methods used in the study were microscopy, X-ray diffraction, transmission electron microscopy and differential thermal analysis. The investigations showed that mullite forms in glassy fibres of the system Al 2 O 3 . SiO 2 from 850 degrees Celsius to 990 degrees Celsius as 2/1 mullite; 3/2 mullite appeared above 990 degrees Celsius besides the crystallization of cristobalite. Fibres with 95 per cent Al 2 O 3 include the phases delta-Al 2 O 3 and alpha- Al 2 O 3 and mullite. Delta- Al 2 O 3 is stable up to 1 100 degrees Celsius. Alpha-Al 2 O 3 and mullite are only stable phases at 1 400 degrees Celsius. These different crystal phases influence the quality of the technical fibre according to the stability field of glass and crystals. This study has determined that it is possible to identify different fibres from different productions by their mineralogical compositions and to relate them to the high temperature application

  12. Spheroidization of glass powders for glass ionomer cements.

    Science.gov (United States)

    Gu, Y W; Yap, A U J; Cheang, P; Kumar, R

    2004-08-01

    Commercial angular glass powders were spheroidized using both the flame spraying and inductively coupled radio frequency plasma spraying techniques. Spherical powders with different particle size distributions were obtained after spheroidization. The effects of spherical glass powders on the mechanical properties of glass ionomer cements (GICs) were investigated. Results showed that the particle size distribution of the glass powders had a significant influence on the mechanical properties of GICs. Powders with a bimodal particle size distribution ensured a high packing density of glass ionomer cements, giving relatively high mechanical properties of GICs. GICs prepared by flame-spheroidized powders showed low strength values due to the loss of fine particles during flame spraying, leading to a low packing density and few metal ions reacting with polyacrylic acid to form cross-linking. GICs prepared by the nano-sized powders showed low strength because of the low bulk density of the nano-sized powders and hence low powder/liquid ratio of GICs.

  13. Characterization and Morphological Properties of Glass Fiber ...

    African Journals Online (AJOL)

    PROF HORSFALL

    used as the matrix for the glass fibre-epoxy resin formation. E- Glass fibre ... reinforcement of composites, coatings of materials, and other ..... composite for the manufacture of glass-ceramic materials ... reinforced epoxy composites with carbon.

  14. Optical properties of alkaline earth borate glasses

    African Journals Online (AJOL)

    user

    The alkaline earth borate glasses containing heavy metal oxides show good solubility of rare-earth ions. Glasses containing PbO exhibit low glass transition temperature (Tg) and high ..... These oxygen ions carry a partial negative charge and.

  15. Optical properties of alkaline earth borate glasses

    African Journals Online (AJOL)

    user

    ... devices; radiation shields, surgical lasers and their glass ceramic counter ... Alkaline earth oxides improve glass forming capability while heavy metal ... reports on optical properties of MO-B2O3 glasses containing alkaline earth oxides.

  16. Properties of gallium lanthanum sulphide glass

    OpenAIRE

    Bastock, P.; Craig, C.; Khan, K.; Weatherby, E.; Yao, J.; Hewak, D.W.

    2015-01-01

    A series of gallium lanthanum sulphide (GLS) glasses has been studied in order to ascertain properties across the entire glass forming region. This is the first comprehensive study of GLS glass over a wide compositional range.

  17. Who will buy smart glasses?

    DEFF Research Database (Denmark)

    Rauschnabel, Philipp; Brem, Alexander; Ivens, Bjørn S.

    2015-01-01

    Recent market studies reveal that augmented reality (AR) devices, such as smart glasses, will substantially influence the media landscape. Yet, little is known about the intended adoption of smart glasses, particularly: Who are the early adopters of such wearables? We contribute to the growing bo...

  18. Superconductive analogue of spin glasses

    International Nuclear Information System (INIS)

    Feigel'man, M.; Ioffe, L.; Vinokur, V.; Larkin, A.

    1987-07-01

    The properties of granular superconductors in magnetic fields, namely the existence of a new superconductive state analogue of the low-temperature superconductive state in spin glasses are discussed in the frame of the infinite-range model and the finite-range models. Experiments for elucidation of spin-glass superconductive state in real systems are suggested. 30 refs

  19. Zirconium based bulk metallic glasses

    International Nuclear Information System (INIS)

    Dey, G.K.; Neogy, S.; Savalia, R.T.; Tewari, R.; Srivastava, D.; Banerjee, S.

    2006-01-01

    Metallic glasses have come into prominence in recent times because their nanocrystalline atomic arrangement imparts many useful and unusual properties to these metallic solids. In this study, bulk glasses have been obtained in Zr based multicomponent alloy by induction melting these alloys in silica crucibles and casting these in form of rods 3 and 6 mm in diameter in a copper mould

  20. International Congress on Glass XII

    Energy Technology Data Exchange (ETDEWEB)

    Doremus, R H; LaCourse, W C; Mackenzie, J D; Varner, J R; Wolf, W W [eds.

    1980-01-01

    A total of 158 papers are included under nine headings: structure and glass formation; optical properties; electrical and magnetic properties; mechanical properties and relaxation; mass transport; chemical durability and surfaces; nucleation; crystallization; and glass ceramics; processing; and automatic controls. Separate abstracts were prepared for eight papers; four of the remaining papers had been processed previously for the data base. (DLC)

  1. OPAL Various Lead Glass Blocks

    CERN Multimedia

    These lead glass blocks were part of a CERN detector called OPAL (one of the four experiments at the LEP particle detector). OPAL uses some 12 000 blocks of glass like this to measure particle energies in the electromagnetic calorimeter. This detector measured the energy deposited when electrons and photons were slowed down and stopped.

  2. Lead-iron phosophate glass

    International Nuclear Information System (INIS)

    Sales, B.C.; Boatner, L.A.

    1988-01-01

    The lead-iron phosphate nuclear waste glasses (LIPNWG) are the subject of the present chapter. They were discovered in 1984 while the authors were attempting to find a sintering aid for certain types of crystalline monazite ceramic high-level nuclear waste forms. In the present chapter, the term waste glass is synonymous with nuclear waste glass (NWG), and the acronym LIP is often used for lead-iron phosphate. Lead-iron phosphate glasses, like many of the previously studied phosphate glasses, are corrosion resistant in aqueous solutions at temperatures below 100 degrees C, and they can be melted and poured at temperatures that are relatively low in comparison with the processing temperatures required for current silicate glass compositions. Unlike the phosphate glasses investigated previously, however, LIPNWGs do not suffer from alteration due to devitrification during realistic and readily, achievable cooling periods. Additionally, lead-iron phosphate glass melts are not nearly as corrosive as the sodium phosphate melts investigated during the 1960s; and, therefore, they can be melted and processed using crucibles made from a variety of materials

  3. Plutonium dioxide dissolution in glass

    Energy Technology Data Exchange (ETDEWEB)

    Vienna, J.D.; Alexander, D.L.; Li, Hong [and others

    1996-09-01

    In the aftermath of the Cold War, the U.S. Department of Energy`s (DOE) Office of Fissile Materials Disposition (OFMD) is charged with providing technical support for evaluation of disposition options for excess fissile materials manufactured for the nation`s defense. One option being considered for the disposition of excess plutonium (Pu) is immobilization by vitrification. The vitrification option entails immobilizing Pu in a host glass and waste package that are criticality-safe (immune to nuclear criticality), proliferation-resistant, and environmentally acceptable for long-term storage or disposal. To prove the technical and economic feasibility of candidate vitrification options it is necessary to demonstrate that PuO{sub 2} feedstock can be dissolved in glass in sufficient quantity. The OFMD immobilization program has set a Pu solubility goal of 10 wt% in glass. The life cycle cost of the vitrification options are strongly influenced by the rate at which PUO{sub 2} dissolves in glass. The total number of process lines needed for vitrification of 50 t of Pu in 10 years is directly dependent upon the time required for Pu dissolution in glass. The objective of this joint Pacific Northwest National Laboratory (PNNL) - Savannah River Technology Center (SRTC) study was to demonstrate a high Pu solubility in glass and to identify on a rough scale the time required for Pu dissolution in the glass. This study was conducted using a lanthanide borosilicate (LaBS) glass composition designed at the SRTC for the vitrification of actinides.

  4. Radiation effects in silicate glasses

    International Nuclear Information System (INIS)

    Bibler, N.E.; Howitt, D.G.

    1988-01-01

    The study of radiation effects in complex silicate glasses has received renewed attention because of their use in special applications such as high level nuclear waste immobilization and fiber optics. Radiation changes the properties of these glasses by altering their electronic and atomic configurations. These alterations or defects may cause dilatations or microscopic phase changes along with absorption centers that limit the optical application of the glasses. Atomic displacements induced in the already disordered structure of the glasses may affect their use where heavy irradiating particles such as alpha particles, alpha recoils, fission fragments, or accelerated ions are present. Large changes (up to 1%) in density may result. In some cases the radiation damage may be severe enough to affect the durability of the glass in aqueous solutions. In the paper, the authors review the literature concerning radiation effects on density, durability, stored energy, microstructure and optical properties of silicate glasses. Both simple glasses and complex glasses used for immobilization of nuclear waste are considered

  5. Plutonium dioxide dissolution in glass

    International Nuclear Information System (INIS)

    Vienna, J.D.; Alexander, D.L.; Li, Hong

    1996-09-01

    In the aftermath of the Cold War, the U.S. Department of Energy's (DOE) Office of Fissile Materials Disposition (OFMD) is charged with providing technical support for evaluation of disposition options for excess fissile materials manufactured for the nation's defense. One option being considered for the disposition of excess plutonium (Pu) is immobilization by vitrification. The vitrification option entails immobilizing Pu in a host glass and waste package that are criticality-safe (immune to nuclear criticality), proliferation-resistant, and environmentally acceptable for long-term storage or disposal. To prove the technical and economic feasibility of candidate vitrification options it is necessary to demonstrate that PuO 2 feedstock can be dissolved in glass in sufficient quantity. The OFMD immobilization program has set a Pu solubility goal of 10 wt% in glass. The life cycle cost of the vitrification options are strongly influenced by the rate at which PUO 2 dissolves in glass. The total number of process lines needed for vitrification of 50 t of Pu in 10 years is directly dependent upon the time required for Pu dissolution in glass. The objective of this joint Pacific Northwest National Laboratory (PNNL) - Savannah River Technology Center (SRTC) study was to demonstrate a high Pu solubility in glass and to identify on a rough scale the time required for Pu dissolution in the glass. This study was conducted using a lanthanide borosilicate (LaBS) glass composition designed at the SRTC for the vitrification of actinides

  6. Phonon scattering in metallic glasses

    International Nuclear Information System (INIS)

    Black, J.L.

    1979-01-01

    The purpose of this article is to review some recent theoretical and experimental developments in the study of metallic glasses at temperatures near or below 1K. In this temperature regime, it appears that practically all glasses, whether metallic or insulating, behave in a similar fashion. The fact that such similarities occur, despite substantial structural differences between metallic and insulating glasses, constitutes a major theoretical challenge. This challenge, however, is not directly addressed in what follows. Instead, the evidence for universal behavior and the theory which is necessary to understand this evidence are emphasized. It turns out that most of this evidence involves a comparison of phonon scattering in metallic glasses with its counterpart in insulating glasses

  7. Glass Ceramic Formulation Data Package

    International Nuclear Information System (INIS)

    Crum, Jarrod V.; Rodriguez, Carmen P.; McCloy, John S.; Vienna, John D.; Chung, Chul-Woo

    2012-01-01

    A glass ceramic waste form is being developed for treatment of secondary waste streams generated by aqueous reprocessing of commercial used nuclear fuel (Crum et al. 2012b). The waste stream contains a mixture of transition metals, alkali, alkaline earths, and lanthanides, several of which exceed the solubility limits of a single phase borosilicate glass (Crum et al. 2009; Caurant et al. 2007). A multi-phase glass ceramic waste form allows incorporation of insoluble components of the waste by designed crystallization into durable heat tolerant phases. The glass ceramic formulation and processing targets the formation of the following three stable crystalline phases: (1) powellite (XMoO4) where X can be (Ca, Sr, Ba, and/or Ln), (2) oxyapatite Yx,Z(10-x)Si6O26 where Y is alkaline earth, Z is Ln, and (3) lanthanide borosilicate (Ln5BSi2O13). These three phases incorporate the waste components that are above the solubility limit of a single-phase borosilicate glass. The glass ceramic is designed to be a single phase melt, just like a borosilicate glass, and then crystallize upon slow cooling to form the targeted phases. The slow cooling schedule is based on the centerline cooling profile of a 2 foot diameter canister such as the Hanford High-Level Waste canister. Up to this point, crucible testing has been used for glass ceramic development, with cold crucible induction melter (CCIM) targeted as the ultimate processing technology for the waste form. Idaho National Laboratory (INL) will conduct a scaled CCIM test in FY2012 with a glass ceramic to demonstrate the processing behavior. This Data Package documents the laboratory studies of the glass ceramic composition to support the CCIM test. Pacific Northwest National Laboratory (PNNL) measured melt viscosity, electrical conductivity, and crystallization behavior upon cooling to identify a processing window (temperature range) for melter operation and cooling profiles necessary to crystallize the targeted phases in the

  8. Database and Interim Glass Property Models for Hanford HLW Glasses

    International Nuclear Information System (INIS)

    Hrma, Pavel R; Piepel, Gregory F; Vienna, John D; Cooley, Scott K; Kim, Dong-Sang; Russell, Renee L

    2001-01-01

    The purpose of this report is to provide a methodology for an increase in the efficiency and a decrease in the cost of vitrifying high-level waste (HLW) by optimizing HLW glass formulation. This methodology consists in collecting and generating a database of glass properties that determine HLW glass processability and acceptability and relating these properties to glass composition. The report explains how the property-composition models are developed, fitted to data, used for glass formulation optimization, and continuously updated in response to changes in HLW composition estimates and changes in glass processing technology. Further, the report reviews the glass property-composition literature data and presents their preliminary critical evaluation and screening. Finally the report provides interim property-composition models for melt viscosity, for liquidus temperature (with spinel and zircon primary crystalline phases), and for the product consistency test normalized releases of B, Na, and Li. Models were fitted to a subset of the screened database deemed most relevant for the current HLW composition region

  9. Glass science tutorial: Lecture No. 7, Waste glass technology for Hanford

    International Nuclear Information System (INIS)

    Kruger, A.A.

    1995-07-01

    This paper presents the details of the waste glass tutorial session that was held to promote knowledge of waste glass technology and how this can be used at the Hanford Reservation. Topics discussed include: glass properties; statistical approach to glass development; processing properties of nuclear waste glass; glass composition and the effects of composition on durability; model comparisons of free energy of hydration; LLW glass structure; glass crystallization; amorphous phase separation; corrosion of refractories and electrodes in waste glass melters; and glass formulation for maximum waste loading

  10. Joints in Tempered Glass Using Glass Dowel Discs

    DEFF Research Database (Denmark)

    Nielsen, Jens Henrik; Poulsen, Peter Noe

    One of the major reasons for using glass in structures is its transparency; however, traditional mechanical joints such as friction joints and steel dowel pinned connections are compromising the transparency. The present paper describes a novel joint which is practically maintaining the complete...... transparency of the glass. This is achieved by using a dowel disc made entirely of tempered glass. The concept of the joint is proved by pilot tests and numerical models. From the work it is seen that the load-carrying capacity of such a connection is similar to what is found for traditionally in-plane loaded...

  11. Experimental calibration and determination of the relative response for Lif: Mg, Ti(TLD-100) dosemeters at 60Co gamma and 60 kVp X-ray energies

    International Nuclear Information System (INIS)

    Marco, M.L.; Gonzalez, L.; Delgado, V.; Vano, E.; Moran, P.

    1985-01-01

    The thermoluminescence efficiency of LiF: Mg, Ti (TLD-100) dosemeters has been determined for photon beams from 60 Co gamma rays and 60 kVp X-rays. It has been proven that light yield varies as a function of the photon energy. An experiment was performed using an X-ray beam whose spectrum has been determined by an X-ray fluorescence method. This enabled a direct calculation of the absorbed doses in the T1 material for the different operation conditions. These values and the experimental ones from measuring T1 intensities have been used to obtain the efficiency for energy X-ray spectrum. From the above values, the dosemeter T1 response, relative to 60 Co, has been evaluated. (author)

  12. Glass packages in interim storage

    International Nuclear Information System (INIS)

    Jacquet-Francillon, N.

    1994-10-01

    This report summarize the current state of knowledge concerning the behavior of type C waste packages consisting of vitrified high-level solutions produced by reprocessing spent fuel. The composition and the physical and chemical properties of the feed solutions are reviewed, and the vitrification process is described. Sodium alumino-borosilicate glass compositions are generally employed - the glass used at la Hague for LWR fuel solutions, for example, contains 45 % SiO 2 . The major physical, chemical, mechanical and thermal properties of the glass are reviewed. In order to allow their thermal power to diminish, the 3630 glass packages produced (as of January 1993) in the vitrification facilities at Marcoule and La Hague are placed in interim storage for several decades. The actual interim storage period has not been defined, as it is closely related to the concept and organization selected for the final destination of the packages: a geological repository. The glass behavior under irradiation is described. Considerable basic and applied research has been conducted to assess the aqueous leaching behavior of nuclear containment glass. The effects of various repository parameters (temperature, flow rate, nature of the environmental materials) have been investigated. The experimental findings have been used to specify a model describing the kinetics of aqueous corrosion of the glass. More generally all the ''source term'' models developed in France by the CEA or by ANDRA are summarized. (author). 152 refs., 33 figs

  13. Glass ceramic seals to inconel

    Science.gov (United States)

    McCollister, Howard L.; Reed, Scott T.

    1983-11-08

    A glass ceramic composition prepared by subjecting a glass composition comprising, by weight, 65-80% SiO.sub.2, 8-16%, Li.sub.2 O, 2-8% , Al.sub.2 O.sub.3, 1-8% K.sub.2 O, 1-5% P.sub.2 O.sub.5 and 1.5-7% B.sub.2 O.sub.3, to the following processing steps of heating the glass composition to a temperature sufficient to crystallize lithium metasilicate therein, holding the glass composition at a temperature and for a time period sufficient to dissolve the lithium metasilicate therein thereby creating cristobalite nucleii, cooling the glass composition and maintaining the composition at a temperature and for a time period sufficient to recrystallize lithium metasilicate therein, and thermally treating the glass composition at a temperature and for a time period sufficient to cause growth of cristobalite and further crystallization of lithium metasilicate producing a glass ceramic composition having a specific thermal expansion coefficient and products containing said composition.

  14. Exposure levels to radiation in a nuclear medicine laboratory: measurements with thermoluminescence dosemeters; Niveles de exposicion a la radiacion en un laboratorio de medicina nuclear: mediciones con dosimetros de termoluminiscencia

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz J, A. [Departamento de Medicina Nuclear del Instituto nacional de Ciencias Medicas y Nutricion Salvador Zubiran, Vasco de Quiroga No. 15, Tlalpan 14000 Mexico D.F. (Mexico)

    2000-07-01

    Since 1996 in the Nuclear medicine Department and another routine and research departments of the National Institute of Medical and Nutrition Sciences (INCMNSZ) are working at least with 12 radioactive sources opened and sealed. However, it was unknown if with the Tl personal dosemeters with lithium fluoride crystals (LiF), could be possible to receive information about the equivalent dose for each radionuclide or if there was some radionuclide that by being low energy emissor or beta energy emissor, it did not represent an ionization power sufficient to excite the crystals of the thermoluminescent dosemeters (DTL). In this work the obtained results with control dosemeters of diverse source opened or sealed are shown, which were put at 1 cm of the LiF crystals during a time exposure 18 hours. Therefore the objective of this work is to verify which sources excite or not to DTL crystals and taking the pertinent safety measures for each radionuclide. The conclusion is that the majority of dosemeters were excited by beta or gamma radiation of the radionuclides and that LiF crystals are able to receive equivalent doses until 1200 mSv, being this a guarantee for the staff, that in an any moment could be exposed to high dose in his working day. Also it was corroborated that the radionuclides more energizer are: iodine-131, iodine-125 and sodium-22 while the phosphorus-32 must be managed with careful, since the exposure to hands can result significant, just like the technetium-99m ({sup 99m} Tc). (Author)

  15. New ICRU quantities for the environmental and individual monitoring. Standardization of individual dosemeters by using external beams of photon radiation; Nuevas magnitudes ICRU para la vigilancia radiologica ambiental e individual. Calibracion de dosimetros personales usando haces externos de fotones

    Energy Technology Data Exchange (ETDEWEB)

    Brosed, A; Delgado, A; Granados, C E

    1987-07-01

    The quantities introduced by ICRU for the radiological monitoring are commented, specially those implied in individual protection against external photons. A procedure is proposed in order to standardize the individual dosemeters by using the kerma in air references of CIEMAT-JEN. The reference radiation beams are described in connection with ISO standards. Provisional values are selected for the appropriate conversion and correction factors. (Author) 23 refs.

  16. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of high temperature peaks in TLD-100 dosemeters; Eficiencias termoluminiscentes relativas proton/gamma y helio/gamma de picos de alta temperatura en dosimetros TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Flores M, E.; Avila, O.; Rodriguez V, M. [ININ, 52750 La Marquesa, Estado de Mexico (Mexico); Massillon, J.L.G.; Buenfil A, E.; Ruiz T, C.; Brandan, M.E. [IFUNAM, 04500 Mexico D.F. (Mexico); Gamboa De Buen, I. [ICN-UNAM, 04500 Mexico D.F. (Mexico)

    2007-07-01

    This work presents measures of relative thermoluminescent efficiency of those high temperature peaks of TLD-100 dosemeters exposed to protons of 1.5 MeV and to helium nuclei of 3 and 7.5 MeV. A rigorous reading and of deconvolution protocol was used for the calculation of the TL efficiencies. Additionally an Excel program that facilitated the deconvolution adjustment process of the glow curves was elaborated. (Author)

  17. A method for making a glass supported system, such glass supported system, and the use of a glass support therefor

    NARCIS (Netherlands)

    Unnikrishnan, S.; Jansen, Henricus V.; Berenschot, Johan W.; Fazal, I.; Louwerse, M.C.; Mogulkoc, B.; Sanders, Remco G.P.; de Boer, Meint J.; Elwenspoek, Michael Curt

    2008-01-01

    The invention relates to a method for making a glass supported micro or nano system, comprising the steps of: i) providing a glass support; ii) mounting at least one system on at least one glass support; and iii) bonding the system to the glass support, such that the system is circumferentially

  18. Glass enamel and glass-ceramic coatings for chemical apparatus

    International Nuclear Information System (INIS)

    Es'kov, A.S.; Oleinik, M.I.; Shabrova, E.A.

    1984-01-01

    Among the known anticorrosion coatings used in chemical engineering, glass enamel base coatings are distinguished by such advantages as a high degree of continuity and chemical resistance. The paper describes basic principles for the creation of acid and alkali resistant glass enamel and ceramic coatings for chemical apparatus. As the result of investgations, glass enamel coatings with increased electrical conductivity and also experimental production compositions of chemical, temperature and radiation resistant coatings for protection of chemical equipment of 12Kh18N10T stainless steel have been developed. The coatings have successfully passed testing under service conditions. A new type of coating is short-term glass enamel, which may be recommended for use in chemical machinery manufacturing and other branches of industry in oxidation-free heating and forming of stainless steels

  19. Restorative glass: reversible, discreet restoration using structural glass components

    Directory of Open Access Journals (Sweden)

    Faidra Oikonomopoulou

    2017-12-01

    Full Text Available The application of structural glass as the principal material in restoration and conservation practices is a distinguishable, yet discreet approach. The transparency of glass allows the simultaneous perception of the monument at both its original and present condition, preserving its historical and aesthetical integrity. Concurrently, the material’s unique mechanical properties enable the structural consolidation of the monument. As a proof of concept, the restoration of Lichtenberg Castle is proposed. Solid cast glass units are suggested to complete the missing parts, in respect to the existing construction technique and aesthetics of the original masonry. Aiming for a reversible system, the glass units are interlocking, ensuring the overall stability without necessitating permanent, adhesive connections. This results in an elegant and reversible intervention.

  20. GLASS COMPOSITION-TCLP RESPONSE MODEL FOR WASTE GLASSES

    International Nuclear Information System (INIS)

    Kim, Dong-Sang; Vienna, John D.

    2004-01-01

    A first-order property model for normalized Toxicity Characteristic Leaching Procedure (TCLP) release as a function of glass composition was developed using data collected from various studies. The normalized boron release is used to estimate the release of toxic elements based on the observation that the boron release represents the conservative release for those constituents of interest. The current TCLP model has two targeted application areas: (1) delisting of waste-glass product as radioactive (not mixed) waste and (2) designating the glass wastes generated from waste-glass research activities as hazardous or non-hazardous. This paper describes the data collection and model development for TCLP releases and discusses the issues related to the application of the model

  1. The ions displacement through glasses

    International Nuclear Information System (INIS)

    Sevegnani, F.X.

    1980-01-01

    A method to introduce sodium, potassium, lithium, calcium, iron and other ions in vacuum or gas light bulb by mean of a strong stationay electric field. The experiments showed that the mass deposited inside the bulbs obey Faraday's law of electrolysis, although the process of mass transfer is not that of a conventional electrolysis. A method which allows to show that hydrogen ions do not penetrate the glass structure is also described. Using radioactive tracers, it is shown that heavy ions, such PO 4 --- do not penetrate the glass structure. The vitreous state and the glass properties were studied for interpreting experimental results. (Author) [pt

  2. Recent developments in laser glasses

    International Nuclear Information System (INIS)

    Weber, M.J.

    1983-01-01

    The past decade has witnessed a proliferation of new glass-forming compositions including oxides, halides, oxyhalides, and chalcogenides. Many of these glasses are applicable to lasers and have greatly expanded the range of optical properties and spectroscopic parameters available to the laser designer. Our knowledge and understanding of many properties of interest for laser action - transparency, linear and nonlinear refractive indices, and damage threshold of the host glass and the absorption spectrum, radiative and nonradiative transition probabilities, fluorescence wavelength, stimulated emission cross section, and spectroscopic inhomogeneities of the lasing ion Nd 3 + - are reviewed

  3. Shattered glass seeking the densest matter: the color glass condensate

    CERN Multimedia

    Appell, D

    2004-01-01

    "Physicists investigating heavy-particle collisions believe they are on the track of a universal form of matter, one common to very high energy particles ranging from protons to heavy nuclei such as uranium. Some think that this matter, called a color glass condensate, may explain new nuclear properties and the process of particle formation during collisions. Experimentalists have recently reported intriguing data that suggest a color glass condensate has actually formed in past work" (1 page)

  4. Properties Of Soda/Yttria/Silica Glasses

    Science.gov (United States)

    Angel, Paul W.; Hann, Raiford E.

    1994-01-01

    Experimental study of glass-formation compositional region of soda/ yttria/silicate system and of selected physical properties of glasses within compositional region part of continuing effort to identify glasses with high coefficients of thermal expansion and high softening temperatures, for use as coatings on superalloys and as glass-to-metal seals.

  5. Investigation of dosimetric characteristics of the high sensitivity LiF:Mg,Cu,P thermoluminescent dosemeter and its applications in diagnostic radiology

    Energy Technology Data Exchange (ETDEWEB)

    Fung, K.K.L

    2000-12-01

    The recent introduction and development of the thermoluminescent (T.L.) phosphor material LiF:Mg,Cu,P (usually named TLD100H or GR200A) has aroused intense interest of scientists in the field of radiation dosimetry due to its very favourable dosimetric characteristics. Both conventional LiF:Mg,Ti (TLD100) and LiF:Mg,Cu,P T.L. phosphors are tissue-equivalent but GR200A outperforms in respect of its very much higher sensitivity, by a factor of greater than 25, and a dose detection threshold of less than 1 {mu}Gy. A reproducible readout and annealing regime was developed in the initial part of this study with the newly installed automatic TLD (Thermoluminescence Dosimetry) apparatus in the X-ray and Radiation Physics Laboratories of the Hong Kong Polytechnic University. Basic dosimetric characteristics of this T.L. dosemeter (supplied by Harshaw-Bicron Co.) were then investigated. This paved the foundation for subsequent selected novel application studies in diagnostic radiology. Dosimetric characteristics which included linearity, reproducibility, batch uniformity, energy response, and minimum detectable dose were studied using X-rays in the commonly used diagnostic radiology energy range. Favourable dosimetric characteristics were observed from this T.L. phosphor, which agrees well with published studies. The effect of the number of thermal treatment cycles in the initialisation process on dosimetric properties of this T.L. phosphor was also investigated. This study exploits the favourable dosimetric properties of these T.L. dosemeters in some selected novel dosimetric applications in diagnostic radiology with an anthropomorphic phantom using facilities both in these laboratories and also in radiology departments of various district hospitals in Hong Kong. Radiation absorbed dose from the direct or scattered beam, at critical sites inside and on the surface of the phantom, were measured in these radiological studies. The special focus in some of these studies was to

  6. Investigation of dosimetric characteristics of the high sensitivity LiF:Mg,Cu,P thermoluminescent dosemeter and its applications in diagnostic radiology

    International Nuclear Information System (INIS)

    Fung, K.K.L.

    2000-12-01

    The recent introduction and development of the thermoluminescent (T.L.) phosphor material LiF:Mg,Cu,P (usually named TLD100H or GR200A) has aroused intense interest of scientists in the field of radiation dosimetry due to its very favourable dosimetric characteristics. Both conventional LiF:Mg,Ti (TLD100) and LiF:Mg,Cu,P T.L. phosphors are tissue-equivalent but GR200A outperforms in respect of its very much higher sensitivity, by a factor of greater than 25, and a dose detection threshold of less than 1 μGy. A reproducible readout and annealing regime was developed in the initial part of this study with the newly installed automatic TLD (Thermoluminescence Dosimetry) apparatus in the X-ray and Radiation Physics Laboratories of the Hong Kong Polytechnic University. Basic dosimetric characteristics of this T.L. dosemeter (supplied by Harshaw-Bicron Co.) were then investigated. This paved the foundation for subsequent selected novel application studies in diagnostic radiology. Dosimetric characteristics which included linearity, reproducibility, batch uniformity, energy response, and minimum detectable dose were studied using X-rays in the commonly used diagnostic radiology energy range. Favourable dosimetric characteristics were observed from this T.L. phosphor, which agrees well with published studies. The effect of the number of thermal treatment cycles in the initialisation process on dosimetric properties of this T.L. phosphor was also investigated. This study exploits the favourable dosimetric properties of these T.L. dosemeters in some selected novel dosimetric applications in diagnostic radiology with an anthropomorphic phantom using facilities both in these laboratories and also in radiology departments of various district hospitals in Hong Kong. Radiation absorbed dose from the direct or scattered beam, at critical sites inside and on the surface of the phantom, were measured in these radiological studies. The special focus in some of these studies was to

  7. Structural principles in network glasses

    International Nuclear Information System (INIS)

    Boolchand, P.

    1986-01-01

    Substantial progress in decoding the structure of network glasses has taken place in the past few years. Crucial insights into the molecular structure of glasses have emerged by application of Raman bond and Moessbauer site spectroscopy. In this context, the complimentary role of each spectroscopy as a check on the interpretation of the other, is perhaps one of the more significant developments in the field. New advances in the theory of the subject have also taken place. It is thus appropriate to inquire what general principles if any, have emerged on the structure of real glasses. The author reviews some of the principal ideas on the structure of inorganic network glasses with the aid of specific examples. (Auth.)

  8. Neutron diffraction studies of glasses

    International Nuclear Information System (INIS)

    Wright, A.C.

    1987-01-01

    A survey is given of the application of neutron diffraction to structural studies of oxide and halide glasses. As with crystalline materials, neutron and X-ray diffraction are the major structural probes for glasses and other amorphous solids, particularly in respect of intermediate range order. The glasses discussed mostly have structures which are dominated by a network in which the bonding is predominantly covalent. The examples discussed demonstrate the power of the neutron diffraction technique in the investigation of the structures of inorganic glasses. The best modern diffraction experiments are capable of providing accurate data with high real space resolution, which if used correctly, are an extremely fine filter for the various structural models proposed in the literature. 42 refs

  9. High Tech Art: Chameleon Glass

    Science.gov (United States)

    1993-01-01

    Dichroic Glass is a technology wherein extremely thin films of metal are vacuum deposited on a glass surface. The coated glass shields spacecraft instruments from cosmic radiation and protects human vision from unfiltered sunlight in space. Because the coating process allows some wavelengths of light and color to reflect and others to pass through, a chameleon effect is produced. Murray Schwartz, a former aerospace engineer, has based his business KROMA on this NASA optical technology. He produces dichroic stained glass windows, mobiles and jewelry. The technique involves deposition of super thin layers of metal oxides applied one layer at a time in a specific order and thickness for the desired effect. His product line is unique and has been very successful.

  10. Inorganic glass ceramic slip rings

    Science.gov (United States)

    Glossbrenner, E. W.; Cole, S. R.

    1972-01-01

    Prototypes of slip rings have been fabricated from ceramic glass, a material which is highly resistant to deterioration due to high temperature. Slip ring assemblies were not structurally damaged by mechanical tests and performed statisfactorily for 200 hours.

  11. Glass-Graphite Composite Materials

    International Nuclear Information System (INIS)

    Mayzan, M.Z.H.; Lloyd, J.W.; Heath, P.G.; Stennett, M.C.; Hyatt, N.C.; Hand, R.J.

    2016-01-01

    A summary is presented of investigations into the potential of producing glass-composite materials for the immobilisation of graphite or other carbonaceous materials arising from nuclear power generation. The methods are primarily based on the production of base glasses which are subsequently sintered with powdered graphite or simulant TRISO particles. Consideration is also given to the direct preparation of glass-graphite composite materials using microwave technology. Production of dense composite wasteforms with TRISO particles was more successful than with powdered graphite, as wasteforms containing larger amounts of graphite were resistant to densification and the glasses tried did not penetrate the pores under the pressureless conditions used. Based on the results obtained it is concluded that the production of dense glassgraphite composite wasteforms will require the application of pressure. (author)

  12. Turning nuclear waste into glass

    Energy Technology Data Exchange (ETDEWEB)

    Pegg, Ian L.

    2015-02-15

    Vitrification has emerged as the treatment option of choice for the most dangerous radioactive waste. But dealing with the nuclear waste legacy of the Cold War will require state-of-the-art facilities and advanced glass formulations.

  13. Glass microspheres for medical applications

    Science.gov (United States)

    Conzone, Samuel David

    Radioactive dysprosium lithium borate glass microspheres have been developed as biodegradable radiation delivery vehicles for the radiation synovectomy treatment of rheumatoid arthritis. Once injected into a diseased joint, the microspheres deliver a potent dose of radiation to the diseased tissue, while a non-uniform chemical reaction converts the glass into an amorphous, porous, hydrated dysprosium phosphate reaction product. The non-radioactive, lithium-borate component is dissolved from the glass (up to 94% weight loss), while the radioactive 165Dy reacts with phosphate anions in the body fluids, and becomes "chemically" trapped in a solid, dysprosium phosphate reaction product that has the same size as the un-reacted glass microsphere. Ethylene diamine tetraacetate (EDTA) chelation therapy can be used to dissolve the dysprosium phosphate reaction product after the radiation delivery has subsided. The dysprosium phosphate reaction product, which formed in vivo in the joint of a Sprague-Dawley rat, was dissolved by EDTA chelation therapy in 100 Gy) of localized beta radiation to a treatment site within the body, followed by complete biodegradability. The non-uniform reaction process is a desirable characteristic for a biodegradable radiation delivery vehicle, but it is also a novel material synthesis technique that can convert a glass to a highly porous materials with widely varying chemical composition by simple, low-temperature, glass/solution reaction. The reaction product formed by nonuniform reaction occupies the same volume as the un-reacted glass, and after drying for 1 h at 300°C, has a specific surface area of ≈200 m2/g, a pore size of ≈30 nm, and a nominal crushing strength of ≈10 MPa. Finally, rhenium glass microspheres, composed of micron-sized, metallic rhenium particles dispersed within a magnesium alumino borate glass matrix were produced by sintering ReO2 powder and glass frit at 1050°C. A 50 mg injection of radioactive rhenium glass

  14. Cesium glass irradiation sources

    International Nuclear Information System (INIS)

    Plodinec, M.J.

    1982-01-01

    The precipitation process for the decontamination of soluble SRP wastes produces a material whose radioactivity is dominated by 137 Cs. Potentially, this material could be vitrified to produce irradiation sources similar to the Hanford CsCl sources. In this report, process steps necessary for the production of cesium glass irradiation sources (CGS), and the nature of the sources produced, are examined. Three options are considered in detail: direct vitrification of precipitation process waste; direct vitrification of this waste after organic destruction; and vitrification of cesium separated from the precipitation process waste. Direct vitrification is compatible with DWPF equipment, but process rates may be limited by high levels of combustible materials in the off-gas. Organic destruction would allow more rapid processing. In both cases, the source produced has a dose rate of 2 x 10 4 rads/hr at the surface. Cesium separation produces a source with a dose rate of 4 x 10 5 at the surface, which is nearer that of the Hanford sources (2 x 10 6 rads/hr). Additional processing steps would be required, as well as R and D to demonstrate that DWPF equipment is compatible with this intensely radioactive material

  15. Sustainable Innovation of Glass Design and Craft

    DEFF Research Database (Denmark)

    Sparre-Petersen, Maria

    2014-01-01

    , reduction of production and transportation of new glass is desirable (Environmental Protection Agency, 2012), and can be realized by recycling glass, that has already been manufactured, used and collected for recycling, but has ended up in landfills due to the market mechanisms that allow manufacturing...... and deposition of glass is reduced Today glass production predominantly consists of window glass, glass wool for insulation and containers such as bottles and jelly jars. Glass craft and design hold only a fraction of the market. Still there is reason to believe that generation and implementation of new...

  16. Contrasting the magnetic response between magnetic-glass and reentrant spin-glass

    OpenAIRE

    Roy, S. B.; Chattopadhyay, M. K.

    2008-01-01

    Magnetic-glass is a recently identified phenomenon in various classes of magnetic systems undergoing a first order magnetic phase transition. We shall highlight here a few experimentally determined characteristics of magnetic-glass and the relevant set of experiments, which will enable to distinguish a magnetic-glass unequivocally from the well known phenomena of spin-glass and reentrant spin-glass.

  17. Glass science tutorial: Lecture number-sign 2, Operating electric glass melters. James N. Edmonson, Lecturer

    International Nuclear Information System (INIS)

    Kruger, A.A.

    1994-10-01

    This report contains basic information on electric furnaces used for glass melting and on the properties of glass useful for the stabilization of radioactive wastes. Furnace nomenclature, furnace types, typical silicate glass composition and properties, thermal conductivity information, kinetics of the melting process, glass furnace refractory materials composition and thermal conductivity, and equations required for the operation of glass melters are included

  18. Investigations on vanadium doped glasses

    International Nuclear Information System (INIS)

    Madhusudana Rao, P.

    2013-01-01

    The glass samples studied in the present work have been prepared by melt quenching technique. They were prepared by mixing and grinding together by appropriate amounts of Li 2 O - Na 2 O - B 2 O 3 doped with V 2 O 5 in an agate motor before transferring into crucible. The mixtures were heated in an electric furnace at 1225K for 20 mm. The melt was then quenched to room temperature by pouring it on plane brass plate and pressing it with another brass plate. White and yellow coloured glasses have been obtained with good optical quality and high transparency. Finally the vitreous sample were annealed for 3 hrs at 423K to relieve residual internal stress and slowly cooled to room temperature. The polished glasses have been used for XRD, FTIR analysis and for DSC report. The DSC thermo grams for all the glasses were recorded on in the temperature range 50-550℃ with a heating rate of 10℃/min. Electron spin resonance and optical absorption of 20Li 2 O - 10 Na 2 O - (70-X)B 2 O 3 doped with XV 2 O 5 glass system are studied. ESR spectra of V 4+ ions doped in the glass exhibit peak at g =1.98. Spin Hamiltonian parameters are calculated. It was found that these parameters are dependent upon alkali ion concentration in the glass and the VO +2 ion in an octahedral coordination with a tetragonal compression. The physical parameters of all glasses were also evaluated with respect to the composition

  19. Perspective: Highly stable vapor-deposited glasses

    Science.gov (United States)

    Ediger, M. D.

    2017-12-01

    This article describes recent progress in understanding highly stable glasses prepared by physical vapor deposition and provides perspective on further research directions for the field. For a given molecule, vapor-deposited glasses can have higher density and lower enthalpy than any glass that can be prepared by the more traditional route of cooling a liquid, and such glasses also exhibit greatly enhanced kinetic stability. Because vapor-deposited glasses can approach the bottom of the amorphous part of the potential energy landscape, they provide insights into the properties expected for the "ideal glass." Connections between vapor-deposited glasses, liquid-cooled glasses, and deeply supercooled liquids are explored. The generality of stable glass formation for organic molecules is discussed along with the prospects for stable glasses of other types of materials.

  20. Production of lightweight foam glass (invited talk)

    DEFF Research Database (Denmark)

    Petersen, Rasmus Rosenlund; König, Jakob; Yue, Yuanzheng

    The foam glass production allows low cost recycling of postconsumer glass and industrial waste materials as foaming agent or as melt resource. Foam glass is commonly produced by utilising milled glass mixed with a foaming agent. The powder mixture is heat-treated to around 10^3.7 – 10^6 Pa s, which...... result in viscous sintering and subsequent foaming of the glass melt. The porous glass melt is cooled down to room temperature to freeze-in the foam structure. The resulting foam glass is applied in constructions as a light weight material to reduce load bearing capacity and as heat insulating material...... in buildings and industry. We foam panel glass from old televisions with different foaming agents. We discuss the foaming ability and the foaming mechanism of different foaming systems. We compare several studies to define a viscous window for preparing low density foam glass. However, preparing foam glass...