WorldWideScience

Sample records for ghz validation standard

  1. New Standards for the Validation of EMC Test Sites particularly above 1 GHz

    Directory of Open Access Journals (Sweden)

    S. Battermann

    2005-01-01

    Full Text Available Standards for the validation of alternative test sites with conducting groundplane exist for the frequency range 30-1000 MHz since the end of the eighties. Recently the procedure for fully anechoic rooms (FAR has been included in CISPR 16 after more than 10 years intensive discussion in standards committees (CENELEC, 2002; CISPR, 2004. But there are no standards available for the validation of alternative test sites above 1 GHz. The responsible working group (WG1 in CISPR/A has drawn up the 7th common draft (CD. A CDV will be published in spring 2005. The German standards committee VDE AK 767.4.1 participates in the drafting of the standard. All suggested measurement procedures proposed in the last CDs have been investigated by measurements and theoretical analysis. This contribution describes the basic ideas and problems of the validation procedure of the test site. Furthermore measurement results and numerical calculations will be presented especially for the use of omni-directional antennas.

  2. Comparison of Antenna Measurement Facilities with the DTU-ESA 12 GHz Validation Standard Antenna within the EU Antenna Centre of Excellence

    DEFF Research Database (Denmark)

    Pivnenko, Sergey; Pallesen, Janus Engberg; Breinbjerg, Olav

    2009-01-01

    The primary objective of many antenna measurement facilities is to provide a specified high accuracy of the measured data. The validation of an antenna measurement facility is the process of proving that such a specified accuracy can be achieved. Since this constitutes a very challenging task, an...

  3. Physical standards and valid caibration

    International Nuclear Information System (INIS)

    Smith, D.B.

    1975-01-01

    The desire for improved nuclear material safeguards has led to the development and use of a number and techniques and instruments for the nondestructive assay (NDA) of special nuclear material. Sources of potential bias in NDA measurements are discussed and methods of eliminating the effects of bias in assay results are suggested. Examples are given of instruments in which these methods have been successfully applied. The results of careful attention to potential sources of assay bias are a significant reduction in the number and complexity of standards required for valid instrument calibration and more credible assay results. (auth)

  4. Icecube: Spaceflight Validation of an 874-GHz Submillimeter Wave Radiometer for Ice Cloud Remote Sensing

    Science.gov (United States)

    Wu, D. L.; Esper, J.; Ehsan, N.; Piepmeier, J. R.; Racette, P.

    2014-12-01

    through environmental testing at GSFC. The concept of operations is to fly the GSFC designed instrument/spacecraft in a LEO orbit and collect the 874-GHz radiance data for a period of at least 28+ days. Communication will be through the WFF's UHF ground station. Mission Operations and data processing and validation will be conducted at GSFC.

  5. KEY COMPARISON: CCEM.RF-K9: International comparison of thermal noise standards between 12.4 GHz and 18 GHz (GT-RF/99-1)

    Science.gov (United States)

    Allal, Djamel; Achkar, Joseph

    2006-01-01

    An international comparison of thermal noise-power measurements has been carried out among five national metrology institutes between 12.4 GHz and 18 GHz. Four transfer standards were measured. The following national institutes participated: BNM-LCIE (France), NPL (United Kingdom), PTB (Germany), NIST (United States of America) and VNIIFTRI (Russia). The Bureau National de Métrologie-Laboratoire Central des Industries Electriques (France) acted as the pilot laboratory for the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  6. Design, Development & Functional Validation of Magnets system in support of 42 GHz Gyrotron in India

    Directory of Open Access Journals (Sweden)

    Pradhan S.

    2017-01-01

    Full Text Available A multi institutional initiative is underway towards the development of 42 GHz, 200 kW gyrotron system in India under the frame work of Department of Science and Technology, Government of India. Indigenous realization comprising of design, fabrication, prototypes and functional validations of an appropriate Magnet System is one of the primary technological objective of these initiatives. The 42 GHz gyrotron magnet system comprises of a warm gun magnet, a NbTi/Cu based high homogenous superconducting cavity magnet and three warm collector magnets. The superconducting cavity magnet has been housed inside a low loss cryostat. The magnet system has been designed in accordance with gyrotron physics and engineering considerations respecting highly homogenous spatial field profile as well as maintaining steep gradient as per the compression and velocity ratios between the emission and resonator regions. The designed magnet system further ensures the co-linearity of the magnetic axis with that of the beam axis with custom winding techniques apart from a smooth collection of beam with the collector magnet profiles. The designed magnets have been wound after several R & D validations. The superconducting magnet has been housed inside a low loss designed cryostat with in-built radial and axial alignment flexibilities to certain extent. The cryostat further houses liquid helium port, liquid nitrogen ports, current communication ports, ports for monitoring helium level and other instrumentations apart from over-pressure safety intensive burst disks etc. The entire magnet system comprising of warm and superconducting magnets has been installed and integrated in the Gyrotron test set-up. The magnet system has been aligned in both warm and when the superconducting cavity magnet is cold. The integrated geometric axes have been experimentally ensured as well as the field profiles have been measured with the magnets being charged. Under experimental conditions

  7. Validation of UARS Microwave Limb Sounder 183 GHz H2O Measurements

    Science.gov (United States)

    Lahoz, W. A.; Suttie, M. R.; Froidevaux, L.; Harwood, R. S.; Lau, C. L.; Lungu, T. A.; Peckham, G. E.; Pumphrey, H. C.; Read, W. G.; Shippony, Z.; hide

    1996-01-01

    The Upper Atmosphere Research Satellite (UARS) microwave limb sounder (MLS) makes measurements of thermal emission at 183.3 GHz which are used to infer the concentration of water vapor over a pressure range of 46-0.2hPa (approximately 20-60 km). We provide a validation of MLS H2O by analyzing the integrity of the measurements, by providing an error characterization, and by comparison with data from other instruments. It is estimated that version 3 MLS H2O retrievals are accurate to within 20-25% in the lower stratosphere and to within 8-13% in the upper stratosphere and lower mesosphere. The precision of a single profile is estimated to be approximately 0.15 parts per million by volume (ppmv) in the midstratosphere and 0.2 ppmv in the lower and upper stratosphere. In the lower mesosphere the estimate of a single profile precision is 0.25-0.45 ppmv. During polar winter conditions, H2O retrievals at 46 hPa can have a substantial contribution from climatology. The vertical resolution of MLS H2O retrievals is approximately 5 km.

  8. Construct Validation of Content Standards for Teaching

    Science.gov (United States)

    van der Schaaf, Marieke F.; Stokking, Karel M.

    2011-01-01

    Current international demands to strengthen the teaching profession have led to an increased development and use of professional content standards. The study aims to provide insight in the construct validity of content standards by researching experts' underlying assumptions and preferences when participating in a delphi method. In three rounds 21…

  9. VAlidation STandard antennas: Past, present and future

    DEFF Research Database (Denmark)

    Drioli, Luca Salghetti; Ostergaard, A; Paquay, M

    2011-01-01

    designed for validation campaigns of antenna measurement ranges. The driving requirements of VAST antennas are their mechanical stability over a given operational temperature range and with respect to any orientation of the gravity field. The mechanical design shall ensure extremely stable electrical....../V-band of telecom satellites. The paper will address requirements for future VASTs and possible architecture for multi-frequency Validation Standard antennas....

  10. Validation of Housing Standards Addressing Accessibility

    DEFF Research Database (Denmark)

    Helle, Tina

    2013-01-01

    The aim was to explore the use of an activity-based approach to determine the validity of a set of housing standards addressing accessibility. This included examination of the frequency and the extent of accessibility problems among older people with physical functional limitations who used...... participant groups were examined. Performing well-known kitchen activities was associated with accessibility problems for all three participant groups, in particular those using a wheelchair. The overall validity of the housing standards examined was poor. Observing older people interacting with realistic...... environments while performing real everyday activities seems to be an appropriate method for assessing accessibility problems....

  11. Validation of evaluated neutron standard cross sections

    International Nuclear Information System (INIS)

    Badikov, S.; Golashvili, T.

    2008-01-01

    Some steps of the validation and verification of the new version of the evaluated neutron standard cross sections were carried out. In particular: -) the evaluated covariance data was checked for physical consistency, -) energy-dependent evaluated cross-sections were tested in most important neutron benchmark field - 252 Cf spontaneous fission neutron field, -) a procedure of folding differential standard neutron data in group representation for preparation of specialized libraries of the neutron standards was verified. The results of the validation and verification of the neutron standards can be summarized as follows: a) the covariance data of the evaluated neutron standards is physically consistent since all the covariance matrices of the evaluated cross sections are positive definite, b) the 252 Cf spectrum averaged standard cross-sections are in agreement with the evaluated integral data (except for 197 Au(n,γ) reaction), c) a procedure of folding differential standard neutron data in group representation was tested, as a result a specialized library of neutron standards in the ABBN 28-group structure was prepared for use in reactor applications. (authors)

  12. Reliability and Validity of 10 Different Standard Setting Procedures.

    Science.gov (United States)

    Halpin, Glennelle; Halpin, Gerald

    Research indicating that different cut-off points result from the use of different standard-setting techniques leaves decision makers with a disturbing dilemma: Which standard-setting method is best? This investigation of the reliability and validity of 10 different standard-setting approaches was designed to provide information that might help…

  13. Computer system validation: an overview of official requirements and standards.

    Science.gov (United States)

    Hoffmann, A; Kähny-Simonius, J; Plattner, M; Schmidli-Vckovski, V; Kronseder, C

    1998-02-01

    A brief overview of the relevant documents for companies in the pharmaceutical industry, which are to be taken into consideration to fulfil computer system validation requirements, is presented. We concentrate on official requirements and valid standards in the USA, European Community and Switzerland. There are basically three GMP-guidelines. their interpretations by the associations of interests like APV and PDA as well as the GAMP Suppliers Guide. However, the three GMP-guidelines imply the same philosophy about computer system validation. They describe more a what-to-do approach for validation, whereas the GAMP Suppliers Guide describes a how-to-do validation. Nevertheless, they do not contain major discrepancies.

  14. Validation of the superconducting 3.9 GHz cavity package for the European X-ray Free Electron Laser

    Science.gov (United States)

    Maiano, C. G.; Branlard, J.; Hüning, M.; Jensch, K.; Kostin, D.; Matheisen, A.; Möller, W.-D.; Sulimov, A.; Vogel, E.; Bosotti, A.; Chen, J. F.; Moretti, M.; Paparella, R.; Pierini, P.; Sertore, D.

    2017-04-01

    A full test of the cavity package concept under realistic operating condition was a necessary step before the assembly of the European XFEL (EXFEL) 3.9 GHz superconducting system and its installation in the accelerator. One cavity, equipped with magnetic shielding, power coupler and frequency tuner has been tested in a specially designed single cavity cryostat in one of the test benches of the DESY Accelerator Module Test Facility (AMTF). The cavity was operated at high pulsed power up to an accelerating field of 24 MV /m , above the quench accelerating field of 21 MV /m achieved during the continuous wave (CW) vertical qualification test and with a large margin with respect to the EXFEL maximum operating specification of 15 MV /m for the 3.9 GHz system. All subsystems under test—coupler, tuner, waveguide tuners, low level radio-frequency (LLRF) system—were qualified to their design performances.

  15. 29 CFR 1607.5 - General standards for validity studies.

    Science.gov (United States)

    2010-07-01

    ...) (hereinafter “A.P.A. Standards”) and standard textbooks and journals in the field of personnel selection. D... market and the job should be considered in the determination of when a validity study is outdated. ...

  16. Development, standardization and validation of social anxiety scale ...

    African Journals Online (AJOL)

    Little attention has been given to social anxiety in Nigeria despite its debilitating effects on the sufferers. The objective of this study was to develop, standardize and validate an instrument (Social Anxiety Scale) with high coefficients of Cronbach Alpha Internal Consistency Split-half reliability and construct validity.

  17. What Type of Knowledge Provides Valid Housing Standards Addressing Accessibility?

    DEFF Research Database (Denmark)

    Helle, Tina; Brandt, Åse; Iwarsson, Susanne

    evaluations of task-surface heights in elderly people’s homes. Applied Ergonomics, 31, 109-119. Kohlbacher, F. (2006). The use of qualitative content analysis in case study research. Forum: Qualitative social research sozialforschung (FQS), Open Journal Systems, vol 7, No1. Kozey, J.W. & Das, B. (2004...... accessibility aspects such as either reach, seat height or space requirements • Targeted primarily industrial workstation design and only wheelchair/scooter users • Addressed positions (standing/seated) and sex difference with respect to reach • Was generated in lab-like environments, using methods...... of the validity of housing standards. Therefore, it is reasonable to question what type of knowledge that provides the most valid standards addressing accessibility and explore the consequences of using an alternative approach. The idea was thus to examine the validity of a set of housing standards using a so...

  18. Making Validated Educational Models Central in Preschool Standards.

    Science.gov (United States)

    Schweinhart, Lawrence J.

    This paper presents some ideas to preschool educators and policy makers about how to make validated educational models central in standards for preschool education and care programs that are available to all 3- and 4-year-olds. Defining an educational model as a coherent body of program practices, curriculum content, program and child, and teacher…

  19. Multicultural Standardization and Validation of TEMAS, a Thematic Apperception Test.

    Science.gov (United States)

    Costantino, Giuseppe; Malgady, Robert G.

    Mental health clinical services research has emphasized the urgency of developing new psychometric instruments for non-biased psychological assessment of minority and non-minority children of diverse cultural groups in the United States. Background multicultural standardization and validation information is presented for Tell-Me-A-Story (TEMAS)--a…

  20. 29 CFR 1607.14 - Technical standards for validity studies.

    Science.gov (United States)

    2010-07-01

    ..., if the behavior results in work product(s), an analysis of the work product(s). Any job analysis.... This job analysis should show the work behavior(s) required for successful performance of the job, or... 29 Labor 4 2010-07-01 2010-07-01 false Technical standards for validity studies. 1607.14 Section...

  1. Millimeter wave VAlidation STandard (mm-VAST) antenna

    DEFF Research Database (Denmark)

    Kim, Oleksiy S.

    This document summarizes the main results of the project “Millimeter wave VAlidation STandard (mm-VAST) antenna” completed by the Technical University of Denmark (DTU) in collaboration with Danish company TICRA for the European Space Agency (ESA) under ESA contract no. 4000109866/13/NL/MH....

  2. Millimeter wave VAlidation STandard (mm-VAST) antenna. Abstract

    DEFF Research Database (Denmark)

    Kim, Oleksiy S.

    This document outlines the background, objectives and the main results of the project “Millimeter wave VAlidation STandard (mm-VAST) antenna” completed by the Technical University of Denmark (DTU) in collaboration with Danish company TICRA for the European Space Agency (ESA) under ESA contract no...

  3. Visualizing and Validating Metadata Traceability within the CDISC Standards.

    Science.gov (United States)

    Hume, Sam; Sarnikar, Surendra; Becnel, Lauren; Bennett, Dorine

    2017-01-01

    The Food & Drug Administration has begun requiring that electronic submissions of regulated clinical studies utilize the Clinical Data Information Standards Consortium data standards. Within regulated clinical research, traceability is a requirement and indicates that the analysis results can be traced back to the original source data. Current solutions for clinical research data traceability are limited in terms of querying, validation and visualization capabilities. This paper describes (1) the development of metadata models to support computable traceability and traceability visualizations that are compatible with industry data standards for the regulated clinical research domain, (2) adaptation of graph traversal algorithms to make them capable of identifying traceability gaps and validating traceability across the clinical research data lifecycle, and (3) development of a traceability query capability for retrieval and visualization of traceability information.

  4. Elaboration of standards referred to human exposure to electromagnetic fields in the range of 9kHz to 300GHz in the National System of Health, Brazil

    International Nuclear Information System (INIS)

    Souza, Joao Henrique Campos de; Giacomet, Andrea Fatima; Cunha, Tarcisio; Drumond, Ivens; Sa, Fabiana O.; Mendes, Paula

    2005-01-01

    The Portaria of the Ministry of Health no. 279 (Ordinance 279), of February 22, 2005, establishes a Working Group-GT with the purpose to elaborate standards relating to human exposure to electromagnetic fields in the range of 9 kHz to 300 GHz in the Sistema Unico de Saude (National System of Health), Brazil. Since then, we have conducted several studies on the biological effects of radiation exposure in this spectral range. The GT proposes the use of the geographical instruments coupled information systems to define an alternative pattern of surveillance, based on the determination of Areas of Risks. Each source of electromagnetic radiation is associated with territorial boundaries that surround it using progressively larger distances, thus determining areas of influence whose intensity is attenuated as the distance to the source increases. This paper presents the main results obtained by the Working Group

  5. Assessing cultural validity in standardized tests in stem education

    Science.gov (United States)

    Gassant, Lunes

    This quantitative ex post facto study examined how race and gender, as elements of culture, influence the development of common misconceptions among STEM students. Primary data came from a standardized test: the Digital Logic Concept Inventory (DLCI) developed by Drs. Geoffrey L. Herman, Michael C. Louis, and Craig Zilles from the University of Illinois at Urbana-Champaign. The sample consisted of a cohort of 82 STEM students recruited from three universities in Northern Louisiana. Microsoft Excel and the Statistical Package for the Social Sciences (SPSS) were used for data computation. Two key concepts, several sub concepts, and 19 misconceptions were tested through 11 items in the DLCI. Statistical analyses based on both the Classical Test Theory (Spearman, 1904) and the Item Response Theory (Lord, 1952) yielded similar results: some misconceptions in the DLCI can reliably be predicted by the Race or the Gender of the test taker. The research is significant because it has shown that some misconceptions in a STEM discipline attracted students with similar ethnic backgrounds differently; thus, leading to the existence of some cultural bias in the standardized test. Therefore the study encourages further research in cultural validity in standardized tests. With culturally valid tests, it will be possible to increase the effectiveness of targeted teaching and learning strategies for STEM students from diverse ethnic backgrounds. To some extent, this dissertation has contributed to understanding, better, the gap between high enrollment rates and low graduation rates among African American students and also among other minority students in STEM disciplines.

  6. IT Security Standards and Legal Metrology - Transfer and Validation

    Science.gov (United States)

    Thiel, F.; Hartmann, V.; Grottker, U.; Richter, D.

    2014-08-01

    Legal Metrology's requirements can be transferred into the IT security domain applying a generic set of standardized rules provided by the Common Criteria (ISO/IEC 15408). We will outline the transfer and cross validation of such an approach. As an example serves the integration of Legal Metrology's requirements into a recently developed Common Criteria based Protection Profile for a Smart Meter Gateway designed under the leadership of the Germany's Federal Office for Information Security. The requirements on utility meters laid down in the Measuring Instruments Directive (MID) are incorporated. A verification approach to check for meeting Legal Metrology's requirements by their interpretation through Common Criteria's generic requirements is also presented.

  7. Standard Problems for CFD Validation for NGNP - Status Report

    International Nuclear Information System (INIS)

    Johnson, Richard W.; Schultz, Richard R.

    2010-01-01

    The U.S. Department of Energy (DOE) is conducting research and development to support the resurgence of nuclear power in the United States for both electrical power generation and production of process heat required for industrial processes such as the manufacture of hydrogen for use as a fuel in automobiles. The project is called the Next Generation Nuclear Plant (NGNP) Project, which is based on a Generation IV reactor concept called the very high temperature reactor (VHTR). The VHTR will be of the prismatic or pebble bed type; the former is considered herein. The VHTR will use helium as the coolant at temperatures ranging from 250 C to perhaps 1000 C. While computational fluid dynamics (CFD) has not previously been used for the safety analysis of nuclear reactors in the United States, it is being considered for existing and future reactors. It is fully recognized that CFD simulation codes will have to be validated for flow physics reasonably close to actual fluid dynamic conditions expected in normal operational and accident situations. The ''Standard Problem'' is an experimental data set that represents an important physical phenomenon or phenomena, whose selection is based on a phenomena identification and ranking table (PIRT) for the reactor in question. It will be necessary to build a database that contains a number of standard problems for use to validate CFD and systems analysis codes for the many physical problems that will need to be analyzed. The first two standard problems that have been developed for CFD validation consider flow in the lower plenum of the VHTR and bypass flow in the prismatic core. Both involve scaled models built from quartz and designed to be installed in the INL's matched index of refraction (MIR) test facility. The MIR facility employs mineral oil as the working fluid at a constant temperature. At this temperature, the index of refraction of the mineral oil is the same as that of the quartz. This provides an advantage to the

  8. Validity and Reliability of Baseline Testing in a Standardized Environment.

    Science.gov (United States)

    Higgins, Kathryn L; Caze, Todd; Maerlender, Arthur

    2017-08-11

    The Immediate Postconcussion Assessment and Cognitive Testing (ImPACT) is a computerized neuropsychological test battery commonly used to determine cognitive recovery from concussion based on comparing post-injury scores to baseline scores. This model is based on the premise that ImPACT baseline test scores are a valid and reliable measure of optimal cognitive function at baseline. Growing evidence suggests that this premise may not be accurate and a large contributor to invalid and unreliable baseline test scores may be the protocol and environment in which baseline tests are administered. This study examined the effects of a standardized environment and administration protocol on the reliability and performance validity of athletes' baseline test scores on ImPACT by comparing scores obtained in two different group-testing settings. Three hundred-sixty one Division 1 cohort-matched collegiate athletes' baseline data were assessed using a variety of indicators of potential performance invalidity; internal reliability was also examined. Thirty-one to thirty-nine percent of the baseline cases had at least one indicator of low performance validity, but there were no significant differences in validity indicators based on environment in which the testing was conducted. Internal consistency reliability scores were in the acceptable to good range, with no significant differences between administration conditions. These results suggest that athletes may be reliably performing at levels lower than their best effort would produce. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  9. IT Security Standards and Legal Metrology – Transfer and Validation

    Directory of Open Access Journals (Sweden)

    Thiel F.

    2014-01-01

    Full Text Available Legal Metrology’s requirements can be transferred into the IT security domain applying a generic set of standardized rules provided by the Common Criteria (ISO/IEC 15408. We will outline the transfer and cross validation of such an approach. As an example serves the integration of Legal Metrology’s requirements into a recently developed Common Criteria based Protection Profile for a Smart Meter Gateway designed under the leadership of the Germany’s Federal Office for Information Security. The requirements on utility meters laid down in the Measuring Instruments Directive (MID are incorporated. A verification approach to check for meeting Legal Metrology’s requirements by their interpretation through Common Criteria’s generic requirements is also presented.

  10. The HSE Management Standards Indicator Tool: concurrent and construct validity.

    Science.gov (United States)

    Marcatto, F; Colautti, L; Larese Filon, F; Luis, O; Ferrante, D

    2014-07-01

    The Health & Safety Executive Management Standards Indicator Tool (HSE-MS IT) is a questionnaire commonly used to assess work-related stress risks at an organizational level. A critical factor in determining whether this instrument is actually useful is that higher levels of stress risk in the work-design domains should predict higher levels of stress and stress-related outcomes in workers. Only a few studies, however, have addressed this issue. To test both the concurrent and construct validity of the HSE-MS IT, by relating it with another widely used instrument, the Job Content Questionnaire (JCQ), and by examining its relationships with a set of work-related stress outcomes. An anonymous cross-sectional questionnaire was administered to a sample of employees in an Italian municipality. The questionnaire included the HSE-MS IT, self-reported measures of job satisfaction, job motivation and stress at work, the Satisfaction with Life Scale and the reduced form of the JCQ. A total of 760 out of 779 employees completed the questionnaire. Results showed moderate to strong correlation among the corresponding HSE-MS IT and JCQ scales. Hierarchical regression highlighted the specific contribution of each of the HSE-MS IT scales in predicting three relevant work-related stress outcomes (self-reported stress, job satisfaction and job motivation), after controlling for gender, age and life satisfaction. Our findings consolidated the HSE-MS IT validity and showed the specific sensitivity of its scales to assess different aspects of work-related distress, including self-perception of stress at work. These results can have practical implications for the occupational well-being of employees. © The Author 2014. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Creation and Validation of Sintered PTFE BRDF Targets & Standards.

    Science.gov (United States)

    Durell, Christopher; Scharpf, Dan; McKee, Greg; L'Heureux, Michelle; Georgiev, Georgi; Obein, Gael; Cooksey, Catherine

    2015-09-21

    Sintered polytetrafluoroethylene (PTFE) is an extremely stable, near-perfect Lambertian reflecting diffuser and calibration standard material that has been used by national labs, space, aerospace and commercial sectors for over two decades. New uncertainty targets of 2 % on-orbit absolute validation in the Earth Observing Systems community have challenged the industry to improve is characterization and knowledge of almost every aspect of radiometric performance (space and ground). Assuming "near perfect" reflectance for angular dependent measurements is no longer going to suffice for many program needs. The total hemispherical spectral reflectance provides a good mark of general performance; but, without the angular characterization of bidirectional reflectance distribution function (BRDF) measurements, critical data is missing from many applications and uncertainty budgets. Therefore, traceable BRDF measurement capability is needed to characterize sintered PTFE's angular response and provide a full uncertainty profile to users. This paper presents preliminary comparison measurements of the BRDF of sintered PTFE from several laboratories to better quantify the BRDF of sintered PTFE, assess the BRDF measurement comparability between laboratories, and improve estimates of measurement uncertainties under laboratory conditions.

  12. California Diploma Project Technical Report III: Validity Study--Validity Study of the Health Sciences and Medical Technology Standards

    Science.gov (United States)

    McGaughy, Charis; Bryck, Rick; de Gonzalez, Alicia

    2012-01-01

    This study is a validity study of the recently revised version of the Health Science Standards. The purpose of this study is to understand how the Health Science Standards relate to college and career readiness, as represented by survey ratings submitted by entry-level college instructors of health science courses and industry representatives. For…

  13. Standards Performance Continuum: Development and Validation of a Measure of Effective Pedagogy.

    Science.gov (United States)

    Doherty, R. William; Hilberg, R. Soleste; Epaloose, Georgia; Tharp, Roland G.

    2002-01-01

    Describes the development and validation of the Standards Performance Continuum (SPC) for assessing teacher performance of the Standards for Effective Pedagogy. Three studies involving Florida, California, and New Mexico public school teachers provided evidence of inter-rater reliability, concurrent validity, and criterion-related validity…

  14. Validation of the superconducting 3.9 GHz cavity package for the European X-ray Free Electron Laser

    Directory of Open Access Journals (Sweden)

    C. G. Maiano

    2017-04-01

    Full Text Available A full test of the cavity package concept under realistic operating condition was a necessary step before the assembly of the European XFEL (EXFEL 3.9 GHz superconducting system and its installation in the accelerator. One cavity, equipped with magnetic shielding, power coupler and frequency tuner has been tested in a specially designed single cavity cryostat in one of the test benches of the DESY Accelerator Module Test Facility (AMTF. The cavity was operated at high pulsed power up to an accelerating field of 24  MV/m, above the quench accelerating field of 21  MV/m achieved during the continuous wave (CW vertical qualification test and with a large margin with respect to the EXFEL maximum operating specification of 15  MV/m for the 3.9 GHz system. All subsystems under test—coupler, tuner, waveguide tuners, low level radio-frequency (LLRF system—were qualified to their design performances.

  15. Validity and Reliability of a Glucometer Against Industry Reference Standards.

    Science.gov (United States)

    Salacinski, Amanda J; Alford, Micah; Drevets, Kathryn; Hart, Sarah; Hunt, Brian E

    2014-01-01

    As an appealing alternative to reference glucose analyzers, portable glucometers are recommended for self-monitoring at home, in the field, and in research settings. The purpose was to characterize the accuracy and precision, and bias of glucometers in biomedical research. Fifteen young (20-36 years; mean = 24.5), moderately to highly active men (n = 10) and women (n = 5), defined by exercising 2 to 3 times a week for the past 6 months, were given an oral glucose tolerance test (OGTT) after an overnight fast. Participants ingested 50, 75, or 150 grams of glucose over a 5-minute period. The glucometer was compared to a reference instrument. The glucometer had 39% of values within 15% of measurements made using the reference instrument ranging from 45.05 to 169.37 mg/dl. There was both a proportional (-0.45 to -0.39) and small fixed (5.06 and 0.90 mg/dl) bias. Results of the present study suggest that the glucometer provided poor validity and reliability results compared to the results provided by the reference laboratory analyzer. The portable glucometers should be used for patient management, but not for diagnosis, treatment, or research purposes. © 2014 Diabetes Technology Society.

  16. Are industry codes and standards a valid cost containment approach

    International Nuclear Information System (INIS)

    Rowley, C.W.; Simpson, G.T.; Young, R.K.

    1990-01-01

    The nuclear industry has historically concentrated on safety design features for many years, but recently has been shifting to the reliability of the operating systems and components. The Navy has already gone through this transition and has found that Reliability Centered Maintenance (RCM) is an invaluable tool to improve the reliability of components, systems, ships, and classes of ships. There is a close correlation of Navy ships and equipment to commercial nuclear power plants and equipment. The Navy has a central engineering and configuration management organization (Naval Sea Systems Command) for over 500 ships, where as the over 100 commercial nuclear power plants and 52 nuclear utilities represent a fragmented owner/management structure. This paper suggests that the results of the application of RCM in the Navy can be duplicated to a large degree in the commercial nuclear power industry by the development and utilization of nuclear codes and standards

  17. 41 CFR 60-3.5 - General standards for validity studies.

    Science.gov (United States)

    2010-07-01

    ... Association, Washington, D.C., 1974) (hereinafter “A.P.A. Standards”) and standard textbooks and journals in... in the relevant labor market and the job should be considered in the determination of when a validity...

  18. Standards and guidelines applicable for the validation of programmable automation systems

    International Nuclear Information System (INIS)

    Haapanen, P.; Maskuniitty, M.

    1993-02-01

    The validation of programmable automation system for an application important to safety in a nuclear power plant requires a comprehensive view about the system quality and reliability. One central point is to get assured that proper international guidelines and standards have been followed in the design, construction and maintenance of the system. The study was directed to locate international standards and guidelines which can support the validation of programmable systems and to evaluate their applicability for the validation of systems on different levels of requirement during their life cycle. The publication reviews the most important international standards (IAEA, ISO, IEC, IEEE) and their basic principles both for system and application program. Several nuclear standards, which have drawn the main attention, and some general programmable automation standards have been examined. In addition one practical automation system has been examined in order to find essential questions. Based on these studies a set of important items for the qualification have been identified

  19. 60-GHz Millimeter-Wave Radio: Principle, Technology, and New Results

    Directory of Open Access Journals (Sweden)

    Nan Guo

    2006-12-01

    Full Text Available The worldwide opening of a massive amount of unlicensed spectra around 60 GHz has triggered great interest in developing affordable 60-GHz radios. This interest has been catalyzed by recent advance of 60-GHz front-end technologies. This paper briefly reports recent work in the 60-GHz radio. Aspects addressed in this paper include global regulatory and standardization, justification of using the 60-GHz bands, 60-GHz consumer electronics applications, radio system concept, 60-GHz propagation and antennas, and key issues in system design. Some new simulation results are also given. Potentials and problems are explained in detail.

  20. Validation of the ASSERT subchannel code for prediction of CHF in standard and non-standard CANDU bundle geometries

    International Nuclear Information System (INIS)

    Kiteley, J.C.; Carver, M.B.; Zhou, Q.N.

    1993-01-01

    The ASSERT code has been developed to address the three-dimensional computation of flow and phase distribution and fuel element surface temperatures within the horizontal subchannels of CANDU PHWR fuel channels, and to provide a detailed prediction of critical heat flux distribution throughout the bundle. The ASSERT subchannel code has been validated extensively against a wide repertoire of experiments; its combination of three-dimensional prediction of local flow conditions with a comprehensive method of predicting critical heat flux (CHF) at these local conditions makes it a unique tool for predicting CHF for situations outside the existing experimental data base. In particular, ASSERT is the only tool available to systematically investigate CHF under conditions of local geometric variations, such as pressure tube creep and fuel element strain. This paper discusses the numerical methodology used in ASSERT, the constitutive relationships incorporated, and the CHF assessment methodology. The evolutionary validation plan is discussed, and early validation exercises are summarized. The paper concentrates, however, on more recent validation exercises in standard and non-standard geometries. 28 refs., 12 figs

  1. Validation of the assert subchannel code: Prediction of CHF in standard and non-standard Candu bundle geometries

    International Nuclear Information System (INIS)

    Carver, M.B.; Kiteley, J.C.; Zhou, R.Q.N.; Junop, S.V.; Rowe, D.S.

    1993-01-01

    The ASSERT code has been developed to address the three-dimensional computation of flow and phase distribution and fuel element surface temperatures within the horizontal subchannels of CANDU PHWR fuel channels, and to provide a detailed prediction of critical heat flux (CHF) distribution throughout the bundle. The ASSERT subchannel code has been validated extensively against a wide repertoire of experiments; its combination of three-dimensional prediction of local flow conditions with a comprehensive method of prediting CHF at these local conditions, makes it a unique tool for predicting CHF for situations outside the existing experimental data base. In particular, ASSERT is an appropriate tool to systematically investigate CHF under conditions of local geometric variations, such as pressure tube creep and fuel element strain. This paper discusses the numerical methodology used in ASSERT, the constitutive relationships incorporated, and the CHF assessment methodology. The evolutionary validation plan is discussed, and early validation exercises are summarized. The paper concentrates, however, on more recent validation exercises in standard and non-standard geometries

  2. Semantic validation of standard-based electronic health record documents with W3C XML schema.

    Science.gov (United States)

    Rinner, C; Janzek-Hawlat, S; Sibinovic, S; Duftschmid, G

    2010-01-01

    The goal of this article is to examine whether W3C XML Schema provides a practicable solution for the semantic validation of standard-based electronic health record (EHR) documents. With semantic validation we mean that the EHR documents are checked for conformance with the underlying archetypes and reference model. We describe an approach that allows XML Schemas to be derived from archetypes based on a specific naming convention. The archetype constraints are augmented with additional components of the reference model within the XML Schema representation. A copy of the EHR document that is transformed according to the before-mentioned naming convention is used for the actual validation against the XML Schema. We tested our approach by semantically validating EHR documents conformant to three different ISO/EN 13606 archetypes respective to three sections of the CDA implementation guide "Continuity of Care Document (CCD)" and an implementation guide for diabetes therapy data. We further developed a tool to automate the different steps of our semantic validation approach. For two particular kinds of archetype prescriptions, individual transformations are required for the corresponding EHR documents. Otherwise, a fully generic validation is possible. In general, we consider W3C XML Schema as a practicable solution for the semantic validation of standard-based EHR documents.

  3. Validation by simulation of a clinical trial model using the standardized mean and variance criteria.

    Science.gov (United States)

    Abbas, Ismail; Rovira, Joan; Casanovas, Josep

    2006-12-01

    To develop and validate a model of a clinical trial that evaluates the changes in cholesterol level as a surrogate marker for lipodystrophy in HIV subjects under alternative antiretroviral regimes, i.e., treatment with Protease Inhibitors vs. a combination of nevirapine and other antiretroviral drugs. Five simulation models were developed based on different assumptions, on treatment variability and pattern of cholesterol reduction over time. The last recorded cholesterol level, the difference from the baseline, the average difference from the baseline and level evolution, are the considered endpoints. Specific validation criteria based on a 10% minus or plus standardized distance in means and variances were used to compare the real and the simulated data. The validity criterion was met by all models for considered endpoints. However, only two models met the validity criterion when all endpoints were considered. The model based on the assumption that within-subjects variability of cholesterol levels changes over time is the one that minimizes the validity criterion, standardized distance equal to or less than 1% minus or plus. Simulation is a useful technique for calibration, estimation, and evaluation of models, which allows us to relax the often overly restrictive assumptions regarding parameters required by analytical approaches. The validity criterion can also be used to select the preferred model for design optimization, until additional data are obtained allowing an external validation of the model.

  4. 60 GHz antenna measurement setup using a VNA without external frequency conversion

    DEFF Research Database (Denmark)

    Popa, Paula Irina; Pivnenko, Sergey; Nielsen, Jeppe Majlund

    2014-01-01

    an alternative solution which makes use of a standard wideband VNA without external frequency conversion units. The operational capability of the Planar Near-Field (PNF) Antenna Measurement Facility at the Technical University of Denmark was recently extended to 60 GHz employing an Agilent E8361A VNA (up to 67...... GHz). The upgrade involved procurement of very few additional components: two cables operational up to 65 GHz and an openended waveguide probe for tests in U-band (40-60 GHz). The first tests have shown good performance of the PNF setup: 50-60 dB dynamic range and small thermal drift in magnitude...... and phase, 0.06 dB and 6 degrees peak-to-peak deviations over 4 hours. A PNF measurement of a 25 dBi Standard Gain Horn was carried out and the results were compared to those from the DTU-ESA Spherical Near-Field Facility with a good agreement in the validity region. Uncertainty investigations regarding...

  5. Open and Distance Education Accreditation Standards Scale: Validity and Reliability Studies

    Science.gov (United States)

    Can, Ertug

    2016-01-01

    The purpose of this study is to develop, and test the validity and reliability of a scale for the use of researchers to determine the accreditation standards of open and distance education based on the views of administrators, teachers, staff and students. This research was designed according to the general descriptive survey model since it aims…

  6. Validating Automated Essay Scoring: A (Modest) Refinement of the "Gold Standard"

    Science.gov (United States)

    Powers, Donald E.; Escoffery, David S.; Duchnowski, Matthew P.

    2015-01-01

    By far, the most frequently used method of validating (the interpretation and use of) automated essay scores has been to compare them with scores awarded by human raters. Although this practice is questionable, human-machine agreement is still often regarded as the "gold standard." Our objective was to refine this model and apply it to…

  7. Seeking a Valid Gold Standard for an Innovative, Dialect-Neutral Language Test

    Science.gov (United States)

    Pearson, Barbara Zurer; Jackson, Janice E.; Wu, Haotian

    2014-01-01

    Purpose: In this study, the authors explored alternative gold standards to validate an innovative, dialect-neutral language assessment. Method: Participants were 78 African American children, ages 5;0 (years;months) to 6;11. Twenty participants had previously been identified as having language impairment. The Diagnostic Evaluation of Language…

  8. Validating the standard for the National Board Dental Examination Part II.

    Science.gov (United States)

    Tsai, Tsung-Hsun; Neumann, Laura M; Littlefield, John H

    2012-05-01

    As part of the overall exam validation process, the Joint Commission on National Dental Examinations periodically reviews and validates the pass/fail standard for the National Board Dental Examination (NBDE), Parts I and II. The most recent standard-setting activities for NBDE Part II used the Objective Standard Setting method. This report describes the process used to set the pass/fail standard for the 2009 exam. The failure rate on the NBDE Part II increased from 5.3 percent in 2008 to 13.7 percent in 2009 and then decreased to 10 percent in 2010. This article describes the Objective Standard Setting method and presents the estimated probabilities of classification errors based on the beta binomial mathematical model. The results show that the probability of correct classifications of candidate performance is very high (0.97) and that probabilities of false negative and false positive errors are very small (.03 and <0.001, respectively). The low probability of classification errors supports the conclusion that the pass/fail score on the NBDE Part II is a valid guide for making decisions about candidates for dental licensure.

  9. Reliability and validity of the Korean standard pattern identification for stroke (K-SPI-Stroke questionnaire

    Directory of Open Access Journals (Sweden)

    Kang Byoung-Kab

    2012-04-01

    Full Text Available Abstract Background The present study was conducted to examine the reliability and validity of the ‘Korean Standard Pattern Identification for Stroke (K-SPI-Stroke’, which was developed and evaluated within the context of traditional Korean medicine (TKM. Methods Between September 2006 and December 2010, 2,905 patients from 11 Korean medical hospitals were asked to complete the K-SPI-Stroke questionnaire as a part of project ' Fundamental study for the standardization and objectification of pattern identification in traditional Korean medicine for stroke (SOPI-Stroke. Each patient was independently diagnosed by two TKM physicians from the same site according to one of four patterns, as suggested by the Korea Institute of Oriental Medicine: 1 a Qi deficiency pattern, 2 a Dampness-phlegm pattern, 3 a Yin deficiency pattern, or 4 a Fire-heat pattern. We estimated the internal consistency using Cronbach’s α coefficient, the discriminant validity using the means score of patterns, and the predictive validity using the classification accuracy of the K-SPI-Stroke questionnaire. Results The K-SPI-Stroke questionnaire had satisfactory internal consistency (α = 0.700 and validity, with significant differences in the mean of scores among the four patterns. The overall classification accuracy of this questionnaire was 65.2 %. Conclusion These results suggest that the K-SPI-Stroke questionnaire is a reliable and valid instrument for estimating the severity of the four patterns.

  10. Characterization of a high-intensity three-qubit GHZ state using state tomography and Gisin's inequality

    Energy Technology Data Exchange (ETDEWEB)

    Lu Huaixin, E-mail: huaixinlu@wfu.edu.c [Department of Physics and Electronic Science, Weifang University, Weifang, Shandong 261061 (China); Zhao Jiaqiang; Wang Xiaoqin [Department of Physics and Electronic Science, Weifang University, Weifang, Shandong 261061 (China)

    2011-05-02

    We experimentally characterized a high-intensity optical three-qubit Greenberger-Horne-Zeilinger (GHZ) states with a count of {approx}25/s by using the method of over-complete state tomography. Furthermore, based on the state, a convincing, 3.5 standard deviations, violation of Gisin's inequality has been measured, thus confirming the validity of Gisin's inequality for three-qubit GHZ states. From the data, we verified the good agreement of the experimental violation with the value predicted by quantum mechanics given the reconstructed density matrix. This result represents the first step towards the experimental implementation of Gisin's theorem. - Highlights: We have characterized a high-intensity three-qubit GHZ states. We have achieved convincing results of the violation of Gisin's inequalities. We verified the agreement of the experimental violation with theoretical value.

  11. Cross-cultural validity of standardized motor development screening and assessment tools: a systematic review.

    Science.gov (United States)

    Mendonça, Bianca; Sargent, Barbara; Fetters, Linda

    2016-12-01

    To investigate whether standardized motor development screening and assessment tools that are used to evaluate motor abilities of children aged 0 to 2 years are valid in cultures other than those in which the normative sample was established. This was a systematic review in which six databases were searched. Studies were selected based on inclusion/exclusion criteria and appraised for evidence level and quality. Study variables were extracted. Twenty-three studies representing six motor development screening and assessment tools in 16 cultural contexts met the inclusion criteria: Alberta Infant Motor Scale (n=7), Ages and Stages Questionnaire, 3rd edition (n=2), Bayley Scales of Infant and Toddler Development, 3rd edition (n=8), Denver Developmental Screening Test, 2nd edition (n=4), Harris Infant Neuromotor Test (n=1), and Peabody Developmental Motor Scales, 2nd edition (n=1). Thirteen studies found significant differences between the cultural context and normative sample. Two studies established reliability and/or validity of standardized motor development assessments in high-risk infants from different cultural contexts. Five studies established new population norms. Eight studies described the cross-cultural adaptation of a standardized motor development assessment. Standardized motor development assessments have limited validity in cultures other than that in which the normative sample was established. Their use can result in under- or over-referral for services. © 2016 Mac Keith Press.

  12. DTU-ESA millimeter-wave validation standard antenna – requirements and design

    DEFF Research Database (Denmark)

    Pivnenko, Sergey; Kim, Oleksiy S.; Breinbjerg, Olav

    2014-01-01

    from a validation campaign is achieved when a dedicated Validation Standard (VAST) antenna specifically designed for this purpose is available. The driving requirements to VAST antennas are their mechanical stability with respect to any orientation of the antenna in the gravity field and thermal...... are briefly reviewed and the baseline design is described. The emphasis is given to definition of the requirements for the mechanical and thermal stability of the antenna, which satisfy the stringent stability requirement for the mm-VAST electrical characteristics....

  13. Validation of uncertainty of weighing in the preparation of radionuclide standards by Monte Carlo Method

    International Nuclear Information System (INIS)

    Cacais, F.L.; Delgado, J.U.; Loayza, V.M.

    2016-01-01

    In preparing solutions for the production of radionuclide metrology standards is necessary measuring the quantity Activity by mass. The gravimetric method by elimination is applied to perform weighing with smaller uncertainties. At this work is carried out the validation, by the Monte Carlo method, of the uncertainty calculation approach implemented by Lourenco and Bobin according to ISO GUM for the method by elimination. The results obtained by both uncertainty calculation methods were consistent indicating that were fulfilled the conditions for the application of ISO GUM in the preparation of radioactive standards. (author)

  14. Validation of the k0 standardization method in neutron activation analysis

    International Nuclear Information System (INIS)

    Kubesova, Marie

    2009-01-01

    The goal of this work was to validate the k 0 standardization method in neutron activation analysis for use by the Nuclear Physics Institute's NAA Laboratory. The precision and accuracy of the method were examined by using two types of reference materials: the one type comprised a set of synthetic materials and served to check the implementation of k 0 standardization, the other type consisted of matrix NIST SRMs comprising various different matrices. In general, a good agreement was obtained between the results of this work and the certified values, giving evidence of the accuracy of our results. In addition, the limits were evaluated for 61 elements

  15. Development of a consensus standard for verification and validation of nuclear system thermal-fluids software

    International Nuclear Information System (INIS)

    Harvego, Edwin A.; Schultz, Richard R.; Crane, Ryan L.

    2011-01-01

    With the resurgence of nuclear power and increased interest in advanced nuclear reactors as an option to supply abundant energy without the associated greenhouse gas emissions of the more conventional fossil fuel energy sources, there is a need to establish internationally recognized standards for the verification and validation (V and V) of software used to calculate the thermal–hydraulic behavior of advanced reactor designs for both normal operation and hypothetical accident conditions. To address this need, ASME (American Society of Mechanical Engineers) Standards and Certification has established the V and V 30 Committee, under the jurisdiction of the V and V Standards Committee, to develop a consensus standard for verification and validation of software used for design and analysis of advanced reactor systems. The initial focus of this committee will be on the V and V of system analysis and computational fluid dynamics (CFD) software for nuclear applications. To limit the scope of the effort, the committee will further limit its focus to software to be used in the licensing of High-Temperature Gas-Cooled Reactors. Although software verification will be an important and necessary part of the standard, much of the initial effort of the committee will be focused on the validation of existing software and new models that could be used in the licensing process. In this framework, the Standard should conform to Nuclear Regulatory Commission (NRC) and other regulatory practices, procedures and methods for licensing of nuclear power plants as embodied in the United States (U.S.) Code of Federal Regulations and other pertinent documents such as Regulatory Guide 1.203, “Transient and Accident Analysis Methods” and NUREG-0800, “NRC Standard Review Plan”. In addition, the Standard should be consistent with applicable sections of ASME NQA-1-2008 “Quality Assurance Requirements for Nuclear Facility Applications (QA)”. This paper describes the general

  16. Validation of IRDFF in 252Cf Standard and IRDF-2002 Reference Neutron Fields

    Directory of Open Access Journals (Sweden)

    Simakov Stanislav

    2016-01-01

    Full Text Available The results of validation of the latest release of International Reactor Dosimetry and Fusion File, IRDFF-1.03, in the standard 252Cf(s.f. and reference 235U(nth,f neutron benchmark fields are presented. The spectrum-averaged cross sections were shown to confirm IRDFF-1.03 in the 252Cf standard spontaneous fission spectrum; that was not the case for the current recommended spectra for 235U(nth,f. IRDFF was also validated in the spectra of the research reactor facilities ISNF, Sigma-Sigma and YAYOI, which are available in the IRDF-2002 collection. The ISNF facility was re-simulated to remove unphysical oscillations in the spectrum. IRDFF-1.03 was shown to reproduce reasonably well the spectrum-averaged data measured in these fields except for the case of YAYOI.

  17. Validation and standardization of the Emotional Skills and Competence Questionnaire (ESCQ among Indian university students

    Directory of Open Access Journals (Sweden)

    Tabassum Rashid

    2009-11-01

    Full Text Available There is a seeming theoretical incoherence surrounding the construct emotional intelligence (EI, as well as the problematic issues related to its measurement. The development of the psychometrically sound measurement tools based on the coherent theoretical models is fundamental for the EI to be considered as a valid construct. The current research is aimed to reexamine the psychometric properties and the factor structure of the Emotional Skills and Competence Questionnaire (ESCQ, as well as to evaluate the convergent validity in terms of its relationship with the multidimensional Emotional Intelligence Scale (EIS developed and standardized in the Indian cultural settings. The results indicated that the self-report measure of emotional competence is reliable and valid. Moreover, the factor structure of the questionnaire is confirmed, and other psychometric properties are found to be much in line with the earlier studies conducted in various cultural backgrounds.

  18. SPIE 9639-49 Creation and Validation of Sintered PTFE BRDF Targets & Standards

    OpenAIRE

    Durell, Christopher; Scharpf, Dan; McKee, Greg; L’Heureux, Michelle; Georgiev, Georgi; Obein, Gael; Cooksey, Catherine

    2015-01-01

    Sintered polytetrafluoroethylene (PTFE) is an extremely stable, near-perfect Lambertian reflecting diffuser and calibration standard material that has been used by national labs, space, aerospace and commercial sectors for over two decades. New uncertainty targets of 2 % on-orbit absolute validation in the Earth Observing Systems community have challenged the industry to improve is characterization and knowledge of almost every aspect of radiometric performance (space and ground). Assuming “n...

  19. Criterion and convergent validity of the Montreal cognitive assessment with screening and standardized neuropsychological testing.

    Science.gov (United States)

    Lam, Benjamin; Middleton, Laura E; Masellis, Mario; Stuss, Donald T; Harry, Robin D; Kiss, Alex; Black, Sandra E

    2013-12-01

    To compare the validity of the Montreal Cognitive Assessment (MoCA) with the criterion standard of standardized neuropsychological testing and to compare the convergent validity of the MoCA with that of existing screening tools and global measures of cognition. Cross-sectional observational study. Tertiary care hospital-based cognitive neurology subspecialty clinic. A convenience sample of 107 individuals with mild Alzheimer's disease (AD, n=75) or mild cognitive impairment (MCI, n=32) from the Sunnybrook Dementia Study. In addition to the MoCA, all participants completed the Mini-Mental State Examination (MMSE), the Mattis Dementia Rating Scale (DRS), and detailed neuropsychological testing. Convergent validity was supported, with MoCA scores correlating well with the MMSE (correlation coefficient (r)=0.66, Pvalidity was supported, with MoCA subscores according to cognitive domain correlating well with analogous neuropsychological tests and, in the case of memory (area under the receiver operating characteristic curve (AUC)=0.86), executive (AUC=0.79), and visuospatial function (AUC=0.79), being reasonably sensitive to impairment in those domains. The MoCA is a valid assessment of cognition that shows good agreement with existing screening tools and global measures (convergent validity) and was superior to the MMSE in this regard. The MoCA domain-specific subscores align with performance on more-detailed neuropsychological tests, suggesting not only good criterion validity for the MoCA, but also that it may be useful in guiding further neuropsychological testing. © 2013, Copyright the Authors Journal compilation © 2013, The American Geriatrics Society.

  20. Brief International Cognitive Assessment for MS (BICAMS): international standards for validation.

    Science.gov (United States)

    Benedict, Ralph H B; Amato, Maria Pia; Boringa, Jan; Brochet, Bruno; Foley, Fred; Fredrikson, Stan; Hamalainen, Paivi; Hartung, Hans; Krupp, Lauren; Penner, Iris; Reder, Anthony T; Langdon, Dawn

    2012-07-16

    An international expert consensus committee recently recommended a brief battery of tests for cognitive evaluation in multiple sclerosis. The Brief International Cognitive Assessment for MS (BICAMS) battery includes tests of mental processing speed and memory. Recognizing that resources for validation will vary internationally, the committee identified validation priorities, to facilitate international acceptance of BICAMS. Practical matters pertaining to implementation across different languages and countries were discussed. Five steps to achieve optimal psychometric validation were proposed. In Step 1, test stimuli should be standardized for the target culture or language under consideration. In Step 2, examiner instructions must be standardized and translated, including all information from manuals necessary for administration and interpretation. In Step 3, samples of at least 65 healthy persons should be studied for normalization, matched to patients on demographics such as age, gender and education. The objective of Step 4 is test-retest reliability, which can be investigated in a small sample of MS and/or healthy volunteers over 1-3 weeks. Finally, in Step 5, criterion validity should be established by comparing MS and healthy controls. At this time, preliminary studies are underway in a number of countries as we move forward with this international assessment tool for cognition in MS.

  1. GPM GROUND VALIDATION DUAL POLARIZATION RADIOMETER GCPEX V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GPM Ground Validation Dual Polarization Radiometer GCPEx dataset provides brightness temperature measurements at frequencies 90 GHz (not polarized) and 150 GHz...

  2. Standardization, Validity and Reliability Study of Gülhane Aphasia Test-2 (GAT-2

    Directory of Open Access Journals (Sweden)

    İlknur Maviş

    2007-04-01

    Full Text Available OBJECTIVE: Gülhane Aphasia Test-2 (GAT-2 has been developed to show the presence of a language disorder ‘aphasia’ and to give the clinician implications for the accompanying speech disorders such as apraxia and dysarthria. OBJECTIVE: The aim of the study was to report standardization, validity and reliability study of GAT-2. METHODS: : 10 healthy individuals were tested initially for the pilot study. 134 healthy individual was included to the standardization study and 30 individuals with aphasia and 11 individuals with right brain injury was included to the validation study. The inter group GAT-2 score differentiations and the effects of age, years of education, sex variances were observed. GAT-2 cut-off scores were calculated by the scores of healthy individuals. GAT-2 test-retest reliability and inter-observer reliability was calculated. RESULTS: Healthy individuals’ GAT-2 scores were significantly different from the GAT-2 scores of aphasic patients, but not from right brain injured patients’. Healthy individuals’ GAT-2 scores were not affected from the sex, age variances but from years of education, so cut-off scores were calculated by this variance. GAT-2 scores of aphasic patients were not affected from age, sex and years of education. Test-retest and inter-observer reliability and internal consistency results showed that GAT-2 is a highly reliable aphasia screening test. CONCLUSION: GAT-2 was found to be a standardized, highly reliable and a valid aphasia test for Turkish stroke patients with aphasia

  3. A 90 GHz photoinjector

    International Nuclear Information System (INIS)

    Palmer, D.T.; Hogan, M.J.; Ferrario, M.; Serafini, L.

    1999-01-01

    Photocathode rf guns depend on mode locked laser systems to produce an electron beam at a given phase of the rf. In general, the laser pulse is less than σ 2 = 10'' of rf phase in length and the required stability is on the order of Δφ = 1 At 90 GHz (W-band), these requirements correspond to σ 2 = 333 fsec and Δφ = 33 fsec. Laser system with pulse lengths in the fsec regime are commercially available, the timing stability is a major concern. It is proposed a multi-cell W-band photoinjector that does not require a mode locked laser system. Thereby eliminating the stability requirements at W-band. The laser pulse is allowed to be many rf periods long. In principle, the photoinjector can now be considered as a thermionic rf gun. Instead of using an alpha magnet to compress the electron bunch, which would have a detrimental effect on the transverse hase space quality due to longitudinal phase space mixing, it is here proposed to use long pulse laser system and a pair of undulators to produce a low emittance, high current, ultra-short electron bunch for beam dynamics experiments in the 90 GHz regime

  4. Update of Standard Practices for New Method Validation in Forensic Toxicology.

    Science.gov (United States)

    Wille, Sarah M R; Coucke, Wim; De Baere, Thierry; Peters, Frank T

    2017-01-01

    International agreement concerning validation guidelines is important to obtain quality forensic bioanalytical research and routine applications as it all starts with the reporting of reliable analytical data. Standards for fundamental validation parameters are provided in guidelines as those from the US Food and Drug Administration (FDA), the European Medicines Agency (EMA), the German speaking Gesellschaft fur Toxikologie und Forensische Chemie (GTFCH) and the Scientific Working Group of Forensic Toxicology (SWGTOX). These validation parameters include selectivity, matrix effects, method limits, calibration, accuracy and stability, as well as other parameters such as carryover, dilution integrity and incurred sample reanalysis. It is, however, not easy for laboratories to implement these guidelines into practice as these international guidelines remain nonbinding protocols, that depend on the applied analytical technique, and that need to be updated according the analyst's method requirements and the application type. In this manuscript, a review of the current guidelines and literature concerning bioanalytical validation parameters in a forensic context is given and discussed. In addition, suggestions for the experimental set-up, the pros and cons of statistical approaches and adequate acceptance criteria for the validation of bioanalytical applications are given. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  5. Validation of a motor activity system by a robotically controlled vehicle and using standard reference compounds.

    Science.gov (United States)

    Patterson, John P; Markgraf, Carrie G; Cirino, Maria; Bass, Alan S

    2005-01-01

    A series of experiments were undertaken to evaluate the accuracy, precision, specificity, and sensitivity of an automated, infrared photo beam-based open field motor activity system, the MotorMonitor v. 4.01, Hamilton-Kinder, LLC, for use in a good laboratory practices (GLP) Safety Pharmacology laboratory. This evaluation consisted of two phases: (1) system validation, employing known inputs using the EM-100 Controller Photo Beam Validation System, a robotically controlled vehicle representing a rodent and (2) biologic validation, employing groups of rats treated with the standard pharmacologic agents diazepam or D-amphetamine. The MotorMonitor's parameters that described the open-field activity of a subject were: basic movements, total distance, fine movements, x/y horizontal ambulations, rearing, and total rest time. These measurements were evaluated over a number of zones within each enclosure. System validation with the EM-100 Controller Photo Beam Validation System showed that all the parameters accurately and precisely measured what they were intended to measure, with the exception of fine movements and x/y ambulations. Biologic validation using the central nervous system depressant diazepam at 1, 2, or 5 mg/kg, i.p. produced the expected dose-dependent reduction in rat motor activity. In contrast, the central nervous system stimulant D-amphetamine produced the expected increases in rat motor activity at 0.1 and 1 mg/kg, i.p, demonstrating the specificity and sensitivity of the system. Taken together, these studies of the accuracy, precision, specificity, and sensitivity show the importance of both system and biologic validation in the evaluation of an automated open field motor activity system for use in a GLP compliant laboratory.

  6. AN ACCURATE FLUX DENSITY SCALE FROM 1 TO 50 GHz

    International Nuclear Information System (INIS)

    Perley, R. A.; Butler, B. J.

    2013-01-01

    We develop an absolute flux density scale for centimeter-wavelength astronomy by combining accurate flux density ratios determined by the Very Large Array between the planet Mars and a set of potential calibrators with the Rudy thermophysical emission model of Mars, adjusted to the absolute scale established by the Wilkinson Microwave Anisotropy Probe. The radio sources 3C123, 3C196, 3C286, and 3C295 are found to be varying at a level of less than ∼5% per century at all frequencies between 1 and 50 GHz, and hence are suitable as flux density standards. We present polynomial expressions for their spectral flux densities, valid from 1 to 50 GHz, with absolute accuracy estimated at 1%-3% depending on frequency. Of the four sources, 3C286 is the most compact and has the flattest spectral index, making it the most suitable object on which to establish the spectral flux density scale. The sources 3C48, 3C138, 3C147, NGC 7027, NGC 6542, and MWC 349 show significant variability on various timescales. Polynomial coefficients for the spectral flux density are developed for 3C48, 3C138, and 3C147 for each of the 17 observation dates, spanning 1983-2012. The planets Venus, Uranus, and Neptune are included in our observations, and we derive their brightness temperatures over the same frequency range.

  7. Basic Laparoscopic Skills Assessment Study: Validation and Standard Setting among Canadian Urology Trainees.

    Science.gov (United States)

    Lee, Jason Y; Andonian, Sero; Pace, Kenneth T; Grober, Ethan

    2017-06-01

    As urology training programs move to a competency based medical education model, iterative assessments with objective standards will be required. To develop a valid set of technical skills standards we initiated a national skills assessment study focusing initially on laparoscopic skills. Between February 2014 and March 2016 the basic laparoscopic skill of Canadian urology trainees and attending urologists was assessed using 4 standardized tasks from the AUA (American Urological Association) BLUS (Basic Laparoscopic Urological Surgery) curriculum, including peg transfer, pattern cutting, suturing and knot tying, and vascular clip applying. All performances were video recorded and assessed using 3 methods, including time and error based scoring, expert global rating scores and C-SATS (Crowd-Sourced Assessments of Technical Skill Global Rating Scale), a novel, crowd sourced assessment platform. Different methods of standard setting were used to develop pass-fail cut points. Six attending urologists and 99 trainees completed testing. Reported laparoscopic experience and training level correlated with performance (p standard setting methods to define pass-fail cut points for all 4 AUA BLUS tasks. The 4 AUA BLUS tasks demonstrated good construct validity evidence for use in assessing basic laparoscopic skill. Performance scores using the novel C-SATS platform correlated well with traditional time-consuming methods of assessment. Various standard setting methods were used to develop pass-fail cut points for educators to use when making formative and summative assessments of basic laparoscopic skill. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  8. ValidatorDB: database of up-to-date validation results for ligands and non-standard residues from the Protein Data Bank.

    Science.gov (United States)

    Sehnal, David; Svobodová Vařeková, Radka; Pravda, Lukáš; Ionescu, Crina-Maria; Geidl, Stanislav; Horský, Vladimír; Jaiswal, Deepti; Wimmerová, Michaela; Koča, Jaroslav

    2015-01-01

    Following the discovery of serious errors in the structure of biomacromolecules, structure validation has become a key topic of research, especially for ligands and non-standard residues. ValidatorDB (freely available at http://ncbr.muni.cz/ValidatorDB) offers a new step in this direction, in the form of a database of validation results for all ligands and non-standard residues from the Protein Data Bank (all molecules with seven or more heavy atoms). Model molecules from the wwPDB Chemical Component Dictionary are used as reference during validation. ValidatorDB covers the main aspects of validation of annotation, and additionally introduces several useful validation analyses. The most significant is the classification of chirality errors, allowing the user to distinguish between serious issues and minor inconsistencies. Other such analyses are able to report, for example, completely erroneous ligands, alternate conformations or complete identity with the model molecules. All results are systematically classified into categories, and statistical evaluations are performed. In addition to detailed validation reports for each molecule, ValidatorDB provides summaries of the validation results for the entire PDB, for sets of molecules sharing the same annotation (three-letter code) or the same PDB entry, and for user-defined selections of annotations or PDB entries. © The Author(s) 2014. Published by Oxford University Press on behalf of Nucleic Acids Research.

  9. Development and Validation of a Standardized Tool for Prioritization of Information Sources.

    Science.gov (United States)

    Akwar, Holy; Kloeze, Harold; Mukhi, Shamir

    2016-01-01

    To validate the utility and effectiveness of a standardized tool for prioritization of information sources for early detection of diseases. The tool was developed with input from diverse public health experts garnered through survey. Ten raters used the tool to evaluate ten information sources and reliability among raters was computed. The Proc mixed procedure with random effect statement and SAS Macros were used to compute multiple raters' Fleiss Kappa agreement and Kendall's Coefficient of Concordance. Ten disparate information sources evaluated obtained the following composite scores: ProMed 91%; WAHID 90%; Eurosurv 87%; MediSys 85%; SciDaily 84%; EurekAl 83%; CSHB 78%; GermTrax 75%; Google 74%; and CBC 70%. A Fleiss Kappa agreement of 50.7% was obtained for ten information sources and 72.5% for a sub-set of five sources rated, which is substantial agreement validating the utility and effectiveness of the tool. This study validated the utility and effectiveness of a standardized criteria tool developed to prioritize information sources. The new tool was used to identify five information sources suited for use by the KIWI system in the CEZD-IIR project to improve surveillance of infectious diseases. The tool can be generalized to situations when prioritization of numerous information sources is necessary.

  10. Validity, Reliability and Standardization Study of the Language Assessment Test for Aphasia

    Directory of Open Access Journals (Sweden)

    Bülent Toğram

    2012-09-01

    Full Text Available OBJECTIVE: Aphasia assessment is the first step towards a well- founded language therapy. Language tests need to consider cultural as well as typological linguistic aspects of a given language. This study was designed to determine the standardization, validity and reliability of Language Assessment Test for Aphasia, which consists of eight subtests including spontaneous speech and language, auditory comprehension, repetition, naming, reading, grammar, speech acts, and writing. METHODS: The test was administered to 282 healthy participants and 92 aphasic participants in age, education and gender matched groups. The validity study of the test was investigated with analysis of content, structure and criterion-related validity. For reliability of the test, the analysis of internal consistency, stability and equivalence reliability was conducted. The influence of variables on healhty participants’ sub-test scores, test score and language score was examined. According to significant differences, norms and cut-off scores based on language score were determined. RESULTS: The group with aphasia performed highly lower than healthy participants on subtest, test and language scores. The test scores of healthy group were mostly affected by age and educational level but not affected by gender. According to significant differences, age and educational level for both groups were determined. Considering age and educational levels, the reference values for the cut-off scores were presented. CONCLUSION: The test was found to be a highly reliable and valid aphasia test for Turkish- speaking aphasic patients either in Turkey or other Turkish communities around the world

  11. Standard values and relationship-specific validity of the Bielefeld Relationship Expectations Questionnaire (BFPE)

    Science.gov (United States)

    2010-01-01

    Background The Bielefeld Partnership Expectations Questionnaire (BFPE) is a tool to assess attachment in the romantic relationships of adults. The attachment styles are operationalized as configuration patterns of scale scores. While convergent validity has already been investigated, discriminant validity is still lacking confirmation. Methods The present sample (n = 1509) is representative for the German population aged 18 to 50. The mean age was 34.6 years. Most of the participants lived in a relationship (77.3 %). Discriminant validity was analyzed using a marital quality questionnaire (PFB), a social support questionnaire (F-Soz-U K-14), and a life satisfaction questionnaire (FLZ). Results All the BFPE scales have a satisfying internal consistency between r = .79 and .86. Those individuals who showed a secure pattern, i.e. increased "Readiness for Self-Disclosure" and "Conscious Need for Care" as well as reduced "Fear of Rejection" experienced their partner as socially supportive, reported higher marital quality in all of its facets, and were more satisfied within the life-domains "family/children" and "relationship/sexuality". Standard values for each scale are presented. Conclusions The BFPE has repeatedly been verified as a short, reliable, and valid instrument applicable to research practice with healthy individuals as well as within clinical contexts. PMID:20942905

  12. A multisite validation of whole slide imaging for primary diagnosis using standardized data collection and analysis.

    Science.gov (United States)

    Wack, Katy; Drogowski, Laura; Treloar, Murray; Evans, Andrew; Ho, Jonhan; Parwani, Anil; Montalto, Michael C

    2016-01-01

    Text-based reporting and manual arbitration for whole slide imaging (WSI) validation studies are labor intensive and do not allow for consistent, scalable, and repeatable data collection or analysis. The objective of this study was to establish a method of data capture and analysis using standardized codified checklists and predetermined synoptic discordance tables and to use these methods in a pilot multisite validation study. Fifteen case report form checklists were generated from the College of American Pathology cancer protocols. Prior to data collection, all hypothetical pairwise comparisons were generated, and a level of harm was determined for each possible discordance. Four sites with four pathologists each generated 264 independent reads of 33 cases. Preestablished discordance tables were applied to determine site by site and pooled accuracy, intrareader/intramodality, and interreader intramodality error rates. Over 10,000 hypothetical pairwise comparisons were evaluated and assigned harm in discordance tables. The average difference in error rates between WSI and glass, as compared to ground truth, was 0.75% with a lower bound of 3.23% (95% confidence interval). Major discordances occurred on challenging cases, regardless of modality. The average inter-reader agreement across sites for glass was 76.5% (weighted kappa of 0.68) and for digital it was 79.1% (weighted kappa of 0.72). These results demonstrate the feasibility and utility of employing standardized synoptic checklists and predetermined discordance tables to gather consistent, comprehensive diagnostic data for WSI validation studies. This method of data capture and analysis can be applied in large-scale multisite WSI validations.

  13. A multisite validation of whole slide imaging for primary diagnosis using standardized data collection and analysis

    Directory of Open Access Journals (Sweden)

    Katy Wack

    2016-01-01

    Full Text Available Context: Text-based reporting and manual arbitration for whole slide imaging (WSI validation studies are labor intensive and do not allow for consistent, scalable, and repeatable data collection or analysis. Objective: The objective of this study was to establish a method of data capture and analysis using standardized codified checklists and predetermined synoptic discordance tables and to use these methods in a pilot multisite validation study. Methods and Study Design: Fifteen case report form checklists were generated from the College of American Pathology cancer protocols. Prior to data collection, all hypothetical pairwise comparisons were generated, and a level of harm was determined for each possible discordance. Four sites with four pathologists each generated 264 independent reads of 33 cases. Preestablished discordance tables were applied to determine site by site and pooled accuracy, intrareader/intramodality, and interreader intramodality error rates. Results: Over 10,000 hypothetical pairwise comparisons were evaluated and assigned harm in discordance tables. The average difference in error rates between WSI and glass, as compared to ground truth, was 0.75% with a lower bound of 3.23% (95% confidence interval. Major discordances occurred on challenging cases, regardless of modality. The average inter-reader agreement across sites for glass was 76.5% (weighted kappa of 0.68 and for digital it was 79.1% (weighted kappa of 0.72. Conclusion: These results demonstrate the feasibility and utility of employing standardized synoptic checklists and predetermined discordance tables to gather consistent, comprehensive diagnostic data for WSI validation studies. This method of data capture and analysis can be applied in large-scale multisite WSI validations.

  14. Validity Study of a Jump Mat Compared to the Reference Standard Force Plate.

    Science.gov (United States)

    Rogan, Slavko; Radlinger, Lorenz; Imhasly, Caroline; Kneubuehler, Andrea; Hilfiker, Roger

    2015-12-01

    In the field of vertical jump diagnostics, force plates (FP) are the reference standard. Recently, despite a lack of evidence, jump mats have been used increasingly. Important factors in favor of jumping mats are their low cost and portability. This validity study compared the Haynl-Elektronik jump mat (HE jump mat) with the reference standard force plate. Ten healthy volunteers participated and each participant completed three series of five drop jumps (DJ). The parameters ground contact time (GCT) and vertical jump height (VJH) from the HE jump mat and the FP were used to evaluate the concurrent validity. The following statistical calculations were performed: Pearson's correlation (r), Bland-Altman plots (standard and for adjusted trend), and regression equations. The Bland-Altman plots suggest that the HE jump mat measures shorter contact times and higher jump heights than the FP. The trend-adjusted Bland-Altman plot shows higher mean differences and wider wing-spreads of confidence limits during longer GCT. During the VJH the mean differences and the wing-spreads of the confidence limits throughout the range present as relatively constant. The following regression equations were created, as close as possible to the true value: GCT = 5.920385 + 1.072293 × [value HE jump mat] and VJH = -1.73777 + 1.011156 × [value HE jump mat]. The HE jump mat can be recommended in relation to the validity of constraints. In this study, only a part of the quality criteria were examined. For the final recommendation it is advised to examine the HE jump mat on the other quality criteria (test-retest reliability, sensitivity change).

  15. Multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocol

    Directory of Open Access Journals (Sweden)

    Felipe Torres Pacheco

    2013-06-01

    Full Text Available Multidetector computed tomography (MDCT scanning has enabled the early diagnosis of hyperacute brain ischemia. We aimed at validating a standardized protocol to read and report MDCT techniques in a series of adult patients. The inter-observer agreement among the trained examiners was tested, and their results were compared with a standard reading. No false positives were observed, and an almost perfect agreement (Kappa>0.81 was documented when the CT angiography (CTA and cerebral perfusion CT (CPCT map data were added to the noncontrast CT (NCCT analysis. The inter-observer agreement was higher for highly trained readers, corroborating the need for specific training to interpret these modern techniques. The authors recommend adding CTA and CPCT to the NCCT analysis in order to clarify the global analysis of structural and hemodynamic brain abnormalities. Our structured report is suitable as a script for the reproducible analysis of the MDCT of patients on suspicion of ischemic stroke.

  16. Methodology for Validation of Housing Standards - the Kitchen as an Example

    DEFF Research Database (Denmark)

    Helle, Tina; Iwarsson, Susanne; Brandt, Åse

    We will present a novel methodology to validate housing standards. Person-environment fit among older persons with different levels of mobility device dependence was investigated during performance of everyday activities in realistic environments. Observational and self-report data were compared...... difficulties in rating accessibility problems. The actual use of mobility devices form part of the activity performance. Some standards are not defined properly to enable activity performance in realistic environments. After attending this activity, participants will be: • Aware of some of the methodological...... challenges concerning sampling and the measurement of accessibility problems among older people with different levels of dependence in mobility device use • Aware of the implications of using observation versus self-report data in research on person-environment fit • Consider the methodological implications...

  17. Use of standard vocabulary services in validation of water resources data

    Science.gov (United States)

    Yu, Jonathan; Cox, Simon; Ratcliffe, David

    2010-05-01

    Ontology repositories are increasingly being exposed through vocabulary and concept services. Primarily this is in support of resource discovery. Thesaurus functionality and even more sophisticated reasoning offers the possibility of overcoming the limitations of simple text-matching and tagging which is the basis of most search. However, controlled vocabularies have other important roles in distributed systems: in particular in constraining content validity. A national water information system established by the Australian Bureau of Meterorology ('the Bureau') has deployed a system for ingestion of data from multiple providers. This uses a http interface onto separately maintained vocabulary services as part of the quality assurance chain. With over 200 data providers potentially transferring data to the Bureau, a standard XML-based Water Data Transfer Format (WDTF) was developed for receipt of data into an integrated national water information system. The WDTF schema was built upon standards from the Open Geospatial Consortium (OGC). The structure and syntax specified by a W3C XML Schema is complemented by additional constraints described using Schematron. These implement important content requirements and business rules including: • Restricted cardinality: where optional elements and attributes inherited from the base standards become mandatory in the application, or repeatable elements or attributes are limited to one or omitted. For example, the sampledFeature element from O&M is optional but is mandatory for a samplingPoint element in WDTF. • Vocabulary checking: WDTF data use seventeen vocabularies or code lists derived from Regulations under the Commonwealth Water Act 2007. Examples of codelists are the Australian Water Regulations list, observed property vocabulary, and units of measures. • Contextual constraints: in many places, the permissible value is dependent on the value of another field. For example, within observations the unit of measure

  18. Assessing validity of a depression screening instrument in the absence of a gold standard.

    Science.gov (United States)

    Gelaye, Bizu; Tadesse, Mahlet G; Williams, Michelle A; Fann, Jesse R; Vander Stoep, Ann; Andrew Zhou, Xiao-Hua

    2014-07-01

    We evaluated the extent to which use of a hypothesized imperfect gold standard, the Composite International Diagnostic Interview (CIDI), biases the estimates of diagnostic accuracy of the Patient Health Questionnaire-9 (PHQ-9). We also evaluate how statistical correction can be used to address this bias. The study was conducted among 926 adults where structured interviews were conducted to collect information about participants' current major depressive disorder using PHQ-9 and CIDI instruments. First, we evaluated the relative psychometric properties of PHQ-9 using CIDI as a gold standard. Next, we used a Bayesian latent class model to correct for the bias. In comparison with CIDI, the relative sensitivity and specificity of the PHQ-9 for detecting major depressive disorder at a cut point of 10 or more were 53.1% (95% confidence interval: 45.4%-60.8%) and 77.5% (95% confidence interval, 74.5%-80.5%), respectively. Using a Bayesian latent class model to correct for the bias arising from the use of an imperfect gold standard increased the sensitivity and specificity of PHQ-9 to 79.8% (95% Bayesian credible interval, 64.9%-90.8%) and 79.1% (95% Bayesian credible interval, 74.7%-83.7%), respectively. Our results provided evidence that assessing diagnostic validity of mental health screening instrument, where application of a gold standard might not be available, can be accomplished by using appropriate statistical methods. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. A standardized approach to verification and validation to assist in expert system development

    International Nuclear Information System (INIS)

    Hines, J.W.; Hajek, B.K.; Miller, D.W.; Haas, M.A.

    1992-01-01

    For the past six years, the Nuclear Engineering Program's Artificial Intelligence (AI) Group at The Ohio State University has been developing an integration of expert systems to act as an aid to nuclear power plant operators. This Operator Advisor consists of four modules that monitor plant parameters, detect deviations from normality, diagnose the root cause of the abnormality, manage procedures to effectively respond to the abnormality, and mitigate its consequences. To aid in the development of this new system, a standardized Verification and Validation (V and V) approach is being implemented. The primary functions are to guide the development of the expert system and to ensure that the end product fulfills the initial objectives. The development process has been divided into eight life-cycle V and V phases from concept to operation and maintenance. Each phase has specific V and V tasks to be performed to ensure a quality end product. Four documents are being used to guide development. The Software Verification and Validation Plan (SVVP) outlines the V and V tasks necessary to verify the product at the end of each software development phase, and to validate that the end product complies with the established software and system requirements and meets the needs of the user. The Software Requirements Specification (SRS) documents the essential requirements of the system. The Software Design Description (SDD) represents these requirements with a specific design. And lastly, the Software Test Document establishes a testing methodology to be used throughout the development life-cycle

  20. Design validation of the ITER EC upper launcher according to codes and standards

    Energy Technology Data Exchange (ETDEWEB)

    Spaeh, Peter, E-mail: peter.spaeh@kit.edu [Karlsruhe Institute of Technology, Institute for Applied Materials, Association KIT-EURATOM, P.O. Box 3640, D-76021 Karlsruhe (Germany); Aiello, Gaetano [Karlsruhe Institute of Technology, Institute for Applied Materials, Association KIT-EURATOM, P.O. Box 3640, D-76021 Karlsruhe (Germany); Gagliardi, Mario [Karlsruhe Institute of Technology, Association KIT-EURATOM, P.O. Box 3640, D-76021 Karlsruhe (Germany); F4E, Fusion for Energy, Joint Undertaking, Barcelona (Spain); Grossetti, Giovanni; Meier, Andreas; Scherer, Theo; Schreck, Sabine; Strauss, Dirk; Vaccaro, Alessandro [Karlsruhe Institute of Technology, Institute for Applied Materials, Association KIT-EURATOM, P.O. Box 3640, D-76021 Karlsruhe (Germany); Weinhorst, Bastian [Karlsruhe Institute of Technology, Institute for Neutron Physics and Reactor Technology, Association KIT-EURATOM, P.O. Box 3640, D-76021 Karlsruhe (Germany)

    2015-10-15

    Highlights: • A set of applicable codes and standards has been chosen for the ITER EC upper launcher. • For a particular component load combinations, failure modes and stress categorizations have been determined. • The design validation was performed in accordance with the “design by analysis”-approach of the ASME boiler and pressure vessel code section III. - Abstract: The ITER electron cyclotron (EC) upper launcher has passed the CDR (conceptual design review) in 2005 and the PDR (preliminary design review) in 2009 and is in its final design phase now. The final design will be elaborated by the European consortium ECHUL-CA with contributions from several research institutes in Germany, Italy, the Netherlands and Switzerland. Within this consortium KIT is responsible for the design of the structural components (the upper port plug, UPP) and also the design integration of the launcher. As the selection of applicable codes and standards was under discussion for the past decade, the conceptual and the preliminary design of the launcher structure were not elaborated in straight accordance with a particular code but with a variety of well-acknowledged engineering practices. For the final design it is compulsory to validate the design with respect to a typical engineering code in order to be compliant with the ITER quality and nuclear requirements and to get acceptance from the French regulator. This paper presents typical design validation of the closure plate, which is the vacuum and Tritium barrier and thus a safety relevant component of the upper port plug (UPP), performed with the ASME boiler and pressure vessel code. Rationales for choosing this code are given as well as a comparison between different design methods, like the “design by rule” and the “design by analysis” approach. Also the selections of proper load specifications and the identification of potential failure modes are covered. In addition to that stress categorizations, analyses

  1. Design validation of the ITER EC upper launcher according to codes and standards

    International Nuclear Information System (INIS)

    Spaeh, Peter; Aiello, Gaetano; Gagliardi, Mario; Grossetti, Giovanni; Meier, Andreas; Scherer, Theo; Schreck, Sabine; Strauss, Dirk; Vaccaro, Alessandro; Weinhorst, Bastian

    2015-01-01

    Highlights: • A set of applicable codes and standards has been chosen for the ITER EC upper launcher. • For a particular component load combinations, failure modes and stress categorizations have been determined. • The design validation was performed in accordance with the “design by analysis”-approach of the ASME boiler and pressure vessel code section III. - Abstract: The ITER electron cyclotron (EC) upper launcher has passed the CDR (conceptual design review) in 2005 and the PDR (preliminary design review) in 2009 and is in its final design phase now. The final design will be elaborated by the European consortium ECHUL-CA with contributions from several research institutes in Germany, Italy, the Netherlands and Switzerland. Within this consortium KIT is responsible for the design of the structural components (the upper port plug, UPP) and also the design integration of the launcher. As the selection of applicable codes and standards was under discussion for the past decade, the conceptual and the preliminary design of the launcher structure were not elaborated in straight accordance with a particular code but with a variety of well-acknowledged engineering practices. For the final design it is compulsory to validate the design with respect to a typical engineering code in order to be compliant with the ITER quality and nuclear requirements and to get acceptance from the French regulator. This paper presents typical design validation of the closure plate, which is the vacuum and Tritium barrier and thus a safety relevant component of the upper port plug (UPP), performed with the ASME boiler and pressure vessel code. Rationales for choosing this code are given as well as a comparison between different design methods, like the “design by rule” and the “design by analysis” approach. Also the selections of proper load specifications and the identification of potential failure modes are covered. In addition to that stress categorizations, analyses

  2. Assessing children’s competence to consent in research by a standardized tool: a validity study

    Science.gov (United States)

    2012-01-01

    Background Currently over 50% of drugs prescribed to children have not been evaluated properly for use in their age group. One key reason why children have been excluded from clinical trials is that they are not considered able to exercise meaningful autonomy over the decision to participate. Dutch law states that competence to consent can be presumed present at the age of 12 and above; however, in pediatric practice children’s competence is not that clearly presented and the transition from assent to active consent is gradual. A gold standard for competence assessment in children does not exist. In this article we describe a study protocol on the development of a standardized tool for assessing competence to consent in research in children and adolescents. Methods/design In this study we modified the MacCAT-CR, the best evaluated competence assessment tool for adults, for use in children and adolescents. We will administer the tool prospectively to a cohort of pediatric patients from 6 to18 years during the selection stages of ongoing clinical trials. The outcomes of the MacCAT-CR interviews will be compared to a reference standard, established by the judgments of clinical investigators, and an expert panel consisting of child psychiatrists, child psychologists and medical ethicists. The reliability, criterion-related validity and reproducibility of the tool will be determined. As MacCAT-CR is a multi-item scale consisting of 13 items, power was justified at 130–190 subjects, providing a minimum of 10–15 observations per item. MacCAT-CR outcomes will be correlated with age, life experience, IQ, ethnicity, socio-economic status and competence judgment of the parent(s). It is anticipated that 160 participants will be recruited over 2 years to complete enrollment. Discussion A validity study on an assessment tool of competence to consent is strongly needed in research practice, particularly in the child and adolescent population. In this study we will establish

  3. Assessing children’s competence to consent in research by a standardized tool: a validity study

    Directory of Open Access Journals (Sweden)

    Hein Irma M

    2012-09-01

    Full Text Available Abstract Background Currently over 50% of drugs prescribed to children have not been evaluated properly for use in their age group. One key reason why children have been excluded from clinical trials is that they are not considered able to exercise meaningful autonomy over the decision to participate. Dutch law states that competence to consent can be presumed present at the age of 12 and above; however, in pediatric practice children’s competence is not that clearly presented and the transition from assent to active consent is gradual. A gold standard for competence assessment in children does not exist. In this article we describe a study protocol on the development of a standardized tool for assessing competence to consent in research in children and adolescents. Methods/design In this study we modified the MacCAT-CR, the best evaluated competence assessment tool for adults, for use in children and adolescents. We will administer the tool prospectively to a cohort of pediatric patients from 6 to18 years during the selection stages of ongoing clinical trials. The outcomes of the MacCAT-CR interviews will be compared to a reference standard, established by the judgments of clinical investigators, and an expert panel consisting of child psychiatrists, child psychologists and medical ethicists. The reliability, criterion-related validity and reproducibility of the tool will be determined. As MacCAT-CR is a multi-item scale consisting of 13 items, power was justified at 130–190 subjects, providing a minimum of 10–15 observations per item. MacCAT-CR outcomes will be correlated with age, life experience, IQ, ethnicity, socio-economic status and competence judgment of the parent(s. It is anticipated that 160 participants will be recruited over 2 years to complete enrollment. Discussion A validity study on an assessment tool of competence to consent is strongly needed in research practice, particularly in the child and adolescent population. In

  4. Diseño y validación de un radar CW-FM a 94 GHz

    OpenAIRE

    Varela Agrelo, David

    2013-01-01

    Diseño y validación de un radar CW-FM a 9g GHz 94 GHz CW-FM radar design and mesurement campaign validation. Desarrollo de un radar CW-FM a 94GHz y verificación de los resultados obtenidos durante la etapa de medidas. Desevolupament d'un radar CW-FM a 94GHz i verificació dels resultat obteinguts durante l'etapa de mesures.

  5. In vivo validation of cardiac output assessment in non-standard 3D echocardiographic images

    Energy Technology Data Exchange (ETDEWEB)

    Nillesen, M M; Lopata, R G P; Gerrits, I H; Thijssen, J M; De Korte, C L [Clinical Physics Laboratory-833, Department of Pediatrics, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands); De Boode, W P [Neonatology, Department of Pediatrics, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands); Huisman, H J [Department of Radiology, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands); Kapusta, L [Pediatric Cardiology, Department of Pediatrics, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands)], E-mail: m.m.nillesen@cukz.umcn.nl

    2009-04-07

    Automatic segmentation of the endocardial surface in three-dimensional (3D) echocardiographic images is an important tool to assess left ventricular (LV) geometry and cardiac output (CO). The presence of speckle noise as well as the nonisotropic characteristics of the myocardium impose strong demands on the segmentation algorithm. In the analysis of normal heart geometries of standardized (apical) views, it is advantageous to incorporate a priori knowledge about the shape and appearance of the heart. In contrast, when analyzing abnormal heart geometries, for example in children with congenital malformations, this a priori knowledge about the shape and anatomy of the LV might induce erroneous segmentation results. This study describes a fully automated segmentation method for the analysis of non-standard echocardiographic images, without making strong assumptions on the shape and appearance of the heart. The method was validated in vivo in a piglet model. Real-time 3D echocardiographic image sequences of five piglets were acquired in radiofrequency (rf) format. These ECG-gated full volume images were acquired intra-operatively in a non-standard view. Cardiac blood flow was measured simultaneously by an ultrasound transit time flow probe positioned around the common pulmonary artery. Three-dimensional adaptive filtering using the characteristics of speckle was performed on the demodulated rf data to reduce the influence of speckle noise and to optimize the distinction between blood and myocardium. A gradient-based 3D deformable simplex mesh was then used to segment the endocardial surface. A gradient and a speed force were included as external forces of the model. To balance data fitting and mesh regularity, one fixed set of weighting parameters of internal, gradient and speed forces was used for all data sets. End-diastolic and end-systolic volumes were computed from the segmented endocardial surface. The cardiac output derived from this automatic segmentation was

  6. In vivo validation of cardiac output assessment in non-standard 3D echocardiographic images

    International Nuclear Information System (INIS)

    Nillesen, M M; Lopata, R G P; Gerrits, I H; Thijssen, J M; De Korte, C L; De Boode, W P; Huisman, H J; Kapusta, L

    2009-01-01

    Automatic segmentation of the endocardial surface in three-dimensional (3D) echocardiographic images is an important tool to assess left ventricular (LV) geometry and cardiac output (CO). The presence of speckle noise as well as the nonisotropic characteristics of the myocardium impose strong demands on the segmentation algorithm. In the analysis of normal heart geometries of standardized (apical) views, it is advantageous to incorporate a priori knowledge about the shape and appearance of the heart. In contrast, when analyzing abnormal heart geometries, for example in children with congenital malformations, this a priori knowledge about the shape and anatomy of the LV might induce erroneous segmentation results. This study describes a fully automated segmentation method for the analysis of non-standard echocardiographic images, without making strong assumptions on the shape and appearance of the heart. The method was validated in vivo in a piglet model. Real-time 3D echocardiographic image sequences of five piglets were acquired in radiofrequency (rf) format. These ECG-gated full volume images were acquired intra-operatively in a non-standard view. Cardiac blood flow was measured simultaneously by an ultrasound transit time flow probe positioned around the common pulmonary artery. Three-dimensional adaptive filtering using the characteristics of speckle was performed on the demodulated rf data to reduce the influence of speckle noise and to optimize the distinction between blood and myocardium. A gradient-based 3D deformable simplex mesh was then used to segment the endocardial surface. A gradient and a speed force were included as external forces of the model. To balance data fitting and mesh regularity, one fixed set of weighting parameters of internal, gradient and speed forces was used for all data sets. End-diastolic and end-systolic volumes were computed from the segmented endocardial surface. The cardiac output derived from this automatic segmentation was

  7. In vivo validation of cardiac output assessment in non-standard 3D echocardiographic images

    Science.gov (United States)

    Nillesen, M. M.; Lopata, R. G. P.; de Boode, W. P.; Gerrits, I. H.; Huisman, H. J.; Thijssen, J. M.; Kapusta, L.; de Korte, C. L.

    2009-04-01

    Automatic segmentation of the endocardial surface in three-dimensional (3D) echocardiographic images is an important tool to assess left ventricular (LV) geometry and cardiac output (CO). The presence of speckle noise as well as the nonisotropic characteristics of the myocardium impose strong demands on the segmentation algorithm. In the analysis of normal heart geometries of standardized (apical) views, it is advantageous to incorporate a priori knowledge about the shape and appearance of the heart. In contrast, when analyzing abnormal heart geometries, for example in children with congenital malformations, this a priori knowledge about the shape and anatomy of the LV might induce erroneous segmentation results. This study describes a fully automated segmentation method for the analysis of non-standard echocardiographic images, without making strong assumptions on the shape and appearance of the heart. The method was validated in vivo in a piglet model. Real-time 3D echocardiographic image sequences of five piglets were acquired in radiofrequency (rf) format. These ECG-gated full volume images were acquired intra-operatively in a non-standard view. Cardiac blood flow was measured simultaneously by an ultrasound transit time flow probe positioned around the common pulmonary artery. Three-dimensional adaptive filtering using the characteristics of speckle was performed on the demodulated rf data to reduce the influence of speckle noise and to optimize the distinction between blood and myocardium. A gradient-based 3D deformable simplex mesh was then used to segment the endocardial surface. A gradient and a speed force were included as external forces of the model. To balance data fitting and mesh regularity, one fixed set of weighting parameters of internal, gradient and speed forces was used for all data sets. End-diastolic and end-systolic volumes were computed from the segmented endocardial surface. The cardiac output derived from this automatic segmentation was

  8. Validity of the standard shiftwork index for South African shiftworkers in the transport industry

    Directory of Open Access Journals (Sweden)

    D. Visser

    1999-06-01

    Full Text Available A major problem in shiftwork research has been the lack of uniform measuring procedures across studies. The Standard Shiftwork Index (SSI contains a battery of self-report questionnaires which was developed to address this need. The objectives of this study included examining the cross- cultural applicability, internal consistency, and construct validity of the SSI scales for a predominantly Afrikaans-speaking sample of 728 train drivers and to provide normative distribution statistics for this sample. Factor analytic results and the correlations between the various scales supported the constnuct validity of the SSI scales. Means obtained on the scales were compared with means obtained for British shiftworkers and non-shiftworkers. The inclusion of job satisfaction and involvement scales, and scales to assess sleep variables appeared to augment an outcome- based theoretical model proposed by the compilers of the SSI. It was concluded that the SSI is a useful research tool for use with shiftworkers, but that further development of some of the scales is advisable. Opsomming 'n Belangrike leemte in navorsing oor skofwerk is die gebrek aan eenvormige metingsprosedures. Die Standard Shiftwork Index (SSI behels verskeie selfbeoordelingvraelyste wat in Engeland ontwikkel is om hierdie behoefte aan te spreek. Die doelwitte van hierdie studie was om die tussenkulturele toepaslikheid, interne konsekwentheid en konstrukgeldigheid van die SSI-skale vir 'n hoofsaaklik Afrikaanssprekende steekproef van 728 treindrywers te bepaal en om normatiewe statistiek vir hierdie steekproef te verskaf. Faktoranalitiese resultate en die korrelasies tussen die onderskeie skale het hul konstrukgeldigheid ondersteun. Gemiddeldes wat op die onderskeie vraelyste behaal is, is vergelyk met gemiddeldes wat vir Britse skofwerkers en nieskofwerkers verkry is. Die insluiting van werktevredenheid- en werkbetrokkenheidskale, asook skale oor slaap, het die uitkomsgebaseerde teoretiese

  9. VALIDATION OF SIMBAT-PWR USING STANDARD CODE OF COBRA-EN ON REACTOR TRANSIENT CONDITION

    Directory of Open Access Journals (Sweden)

    Muhammad Darwis Isnaini

    2016-03-01

    Full Text Available The validation of Pressurized Water Reactor typed Nuclear Power Plant simulator developed by BATAN (SIMBAT-PWR using standard code of COBRA-EN on reactor transient condition has been done. The development of SIMBAT-PWR has accomplished several neutronics and thermal-hydraulic calculation modules. Therefore, the validation of the simulator is needed, especially in transient reactor operation condition. The research purpose is for characterizing the thermal-hydraulic parameters of PWR1000 core, which be able to be applied or as a comparison in developing the SIMBAT-PWR. The validation involves the calculation of the thermal-hydraulic parameters using COBRA-EN code. Furthermore, the calculation schemes are based on COBRA-EN with fixed material properties and dynamic properties that calculated by MATPRO subroutine (COBRA-EN+MATPRO for reactor condition of startup, power rise and power fluctuation from nominal to over power. The comparison of the temperature distribution at nominal 100% power shows that the fuel centerline temperature calculated by SIMBAT-PWR has 8.76% higher result than COBRA-EN result and 7.70% lower result than COBRA-EN+MATPRO. In general, SIMBAT-PWR calculation results on fuel temperature distribution are mostly between COBRA-EN and COBRA-EN+MATPRO results. The deviations of the fuel centerline, fuel surface, inner and outer cladding as well as coolant bulk temperature in the SIMBAT-PWR and the COBRA-EN calculation, are due to the value difference of the gap heat transfer coefficient and the cladding thermal conductivity.

  10. A standardized approach to verification and validation to assist in expert system development

    International Nuclear Information System (INIS)

    Hines, J.W.; Hajek, B.K.; Miller, D.W.; Haas, M.A.

    1992-01-01

    For the past six years, the Nuclear Engineering Program's Artificial Intelligence (AI) Group at The Ohio State University has been developing an integration of expert systems to act as an aid to nuclear power plant operators. This Operator Advisor consists of four modules that monitor plant parameters, detect deviations from normality, diagnose the root cause of the abnormality, manage procedures to effectively respond to the abnormality, and mitigate its consequences. Recently Ohio State University received a grant from the Department of Energy's Special Research Grant Program to utilize the methodologies developed for the Operator Advisor for Heavy Water Reactor (HWR) malfunction root cause diagnosis. To aid in the development of this new system, a standardized Verification and Validation (V ampersand V) approach is being implemented. Its primary functions are to guide the development of the expert system and to ensure that the end product fulfills the initial objectives. The development process has been divided into eight life-cycle V ampersand V phases from concept to operation and maintenance. Each phase has specific V ampersand V tasks to be performed to ensure a quality end product. Four documents are being used to guide development. The Software Verification and Validation Plan (SVVP) outlines the V ampersand V tasks necessary to verify the product at the end of each software development phase, and to validate that the end product complies with the established software and system requirements and meets the needs of the user. The Software Requirements Specification (SRS) documents the essential requirements of the system. The Software Design Description (SDD) represents these requirements with a specific design. And lastly, the Software Test Document establishes a testing methodology to be used throughout the development life-cycle. 10 refs., 1 fig

  11. Reliability and validity of the Farsi version of the standardized assessment of personality-abbreviated scale

    Directory of Open Access Journals (Sweden)

    Maryam Sepehri

    2017-06-01

    Full Text Available Introduction: A short screening tool for high-risk individuals with personality disorder (PD is useful both for clinicians and researchers. The aim of this study was to assess the validity and reliability of the Farsi version of the Standardized Assessment of Personality-Abbreviated Scale (SAPAS. Methods: The original English version of the SAPAS questionnaire was translated into Farsi, and then, translated back into English by two professionals. A survey was then conducted using the questionnaire on 150 clients of primary health care centers in Tabriz, Iran. A total of 235 medical students were also studied for the reliability assessment of the questionnaire. The SAPAS was compared to the short form of Minnesota Multiphasic Personality Inventory (MMPI. The data analysis was performed using receiver operating characteristic (ROC curve technique, operating characteristic for diagnostic efficacy, Cronbach's alpha, and test-retest for reliability evaluation. Results: We found an area under the curve (AUC of 0.566 [95% confidence intervals (CI: 0.455-0.677]; sensitivity of 0.89 and specificity of 0.26 at the cut-off score of 2 and higher. The total Cronbach's alpha coefficient was 0.38 and Cohen's kappa ranged between 0.5 and 0.8. Conclusion: The current study showed that the Farsi version of the SAPAS was relatively less efficient, in term of validity and reliability, in the screening of PD in the population.

  12. Towards continuous improvement of endoscopy standards: Validation of a colonoscopy assessment form.

    LENUS (Irish Health Repository)

    2012-02-01

    Aim: Assessment of procedural colonoscopy skills is an important and topical. The aim of this study was to develop and validate a competency-based colonoscopy assessment form that would be easy to use, suitable for the assessment of junior and senior endoscopists and potentially be a useful instrument to detect differences in performance standards following different training interventions. Method: A standardised assessment form was developed incorporating a checklist with dichotomous yes\\/no responses and a global assessment section incorporating several different elements. This form was used prospectively to evaluate colonoscopy cases during the period of the study in several university teaching hospitals. Results were analysed using ANOVA with Bonferroni corrections for post-hoc analysis. Results: 81 procedures were assessed, performed by eight consultant and 19 trainee endoscopists. There were no serious errors. When divided into three groups based on previous experience (novice, intermediate and expert) the assessment form demonstrated statistically significant differences between all three groups (p<0.05). When separate elements were taken into account, the global assessment section was a better discriminator of skill level than the checklist. Conclusion: This form is a valid, easy to use assessment method. We intend to use it to assess the value of simulator training in trainee endoscopists. It also has the potential to be a useful training tool when feedback is given to the trainee.

  13. [Validity of a standard questionnaire to assess physical activity for specific medical checkups and health guidance].

    Science.gov (United States)

    Kawakami, Ryoko; Miyachi, Motohiko

    2010-10-01

    This study aimed to determine the validity of a standard questionnaire to assess amount of physical activity (PA) and cardiorespiratory fitness (VO2peak). A total of 483 men and women, aged 20 to 69 years, participated. The standard questionnaire included 3 items about exercise, PA, and walking speed. All questions were designed to require an answer of Yes or No. Subjects were classified into one of four groups regarding the number of Yes answers to the three questions, giving activity levels of 0 to 3. The amount of PA was measured objectively with a tn-axial accelerometer which could also calculate daily step counts, and the amounts of PA under 3 metabolic equivalents (METs) and at 3 METs or more. VO2peak. was measured by incremental cycle exercise tests with indirect calorimetry. The daily step counts, the amount of PA at 3 METs or more, and the VO2peak. were significantly higher in subjects who answered Yes to each question than in those who answered No. Sensitivity and specificity of each question were 62-73% and 45-71% for the amount of PA established with the "Exercise and Physical Activity Reference for Health Promotion 2006 (EPAR2006)". The sum of sensitivity and specificity was the highest when the cutoff value was activity level 2 (sensitivity 73%, specificity 68%). Sensitivity and specificity for VO2max established by EPAR2006 were lower than those for the amount of PA. These results suggest that only answering simple questions with a standard questionnaire is sufficient for estimation of PA levels for specific medical checkups and health guidance, even though the accuracy is somewhat limited.

  14. Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies: a report from the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation

    DEFF Research Database (Denmark)

    Falk, Erling

    2012-01-01

    The purpose of this document is to make the output of the International Working Group for Intravascular Optical Coherence Tomography (IWG-IVOCT) Standardization and Validation available to medical and scientific communities, through a peer-reviewed publication, in the interest of improving...

  15. Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies : A report from the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation

    NARCIS (Netherlands)

    G.J. Tearney (Guillermo); E.S. Regar (Eveline); T. Akasaka (Takashi); S. Adriaenssens (Stef); P. Barlis (Peter); H.G. Bezerra (Hiram); B.E. Bouma (Brett); N. Bruining (Nico); J.-M. Cho (Jin-Man); S. Chowdhary (Saqib); M.A. Costa (Marco); R. de Silva (Ranil); J. Dijkstra (Jouke); C. di Mario (Carlo); D. Dudeck (Darius); E. Falk (Erling); M.D. Feldman (Marc); P.J. Fitzgerald (Peter); H.M. Garcia-Garcia (Hector); N. Gonzalo (Nieves); J.F. Granada (Juan); G. Guagliumi (Giulio); N.R. Holm (Niels); Y. Honda (Yasuhiro); F. Ikeno (Fumiaki); Y. Kawasaki; W. Kochman (Waclav); L. Koltowski (Lukasz); T. Kubo (Takashi); T. Kume (Teruyoshi); H. Kyono (Hiroyuki); C.C.S. Lam (Cheung Chi Simon); G. Lamouche (Guy); D.P. Lee (David); M.B. Leon (Martin); A. Maehara (Akiko); O. Manfrini (Olivia); G.S. Mintz (Gary); K. Mizuno (Kyiouchi); M-A.M. Morel (Marie-Angèle); S. Nadkarni (Seemantini); H. Okura (Hiroyuki); H. Otake (Hiromasa); A. Pietrasik (Arkadiusz); F. Prati (Francesco); L. Rber (Lorenz); M. Radu (Maria); N. Rieber (Nikolaus); M. Riga (Maria); S.M. Rollins; M. Rosenberg (Mireille); V. Sirbu (Vasile); P.W.J.C. Serruys (Patrick); K. Shimada; T. Shinke (Toshiro); J. Shite (Junya); E. Siegel (Eliot); S. Sonada (Shinjo); U. Suter (Ueli); S. Takarada (Shigeho); A. Tanaka (Atsushi); M. Terashima (Mitsuyasu); T. Troels (Thim); M. Uemura (Mayu); G.J. Ughi (Giovanni); H.M.M. van Beusekom (Heleen); A.F.W. van der Steen (Ton); G.A. van Es (Gerrit Anne); G. van Soest (Gijs); R. Virmani (Renu); S. Waxman (Sergio); N.J. Weissman (Neil); G. Weisz (Giora)

    2012-01-01

    textabstractObjectives: The purpose of this document is to make the output of the International Working Group for Intravascular Optical Coherence Tomography (IWG-IVOCT) Standardization and Validation available to medical and scientific communities, through a peer-reviewed publication, in the

  16. A 60 GHz Dual-Polarized Probe for Spherical Near-Field Measurements

    DEFF Research Database (Denmark)

    Popa, Paula Irina; Breinbjerg, Olav

    2017-01-01

    to waveguide adapters up to 67 GHz for OMT-switch connection. A 27 dBi gain conical horn is designed by using WIPL-D software and in-house manufactured. The 60 GHz probe system is being assembled and tested in planar near-field (PNF) setup at DTU. The results are validated by comparison with WIPL-D simulations...

  17. 60 GHz Antenna Diagnostics from Planar Near Field Antenna Measurement Without External Frequency Conversion

    DEFF Research Database (Denmark)

    Popa, Paula Irina; Pivnenko, Sergey; Breinbjerg, Olav

    2015-01-01

    ,J.M. Nielsen, O. Breinbjerg, 60 GHz Antenna Measurement Setup using a VNA without External Frequency Conversion,36th Annual Symposium of the Antenna Measurement Technique Association ,October 12-17,Tucson, Arizona, 2014]. In this work we extend the validation of this 60 GHz planar near-field (PNF) set...

  18. Design and validation of standardized clinical and functional remission criteria in schizophrenia

    Science.gov (United States)

    Mosolov, Sergey N; Potapov, Andrey V; Ushakov, Uriy V; Shafarenko, Aleksey A; Kostyukova, Anastasiya B

    2014-01-01

    Background International Remission Criteria (IRC) for schizophrenia were developed recently by a group of internationally known experts. The IRC detect only 10%–30% of cases and do not cover the diversity of forms and social functioning. Our aim was to design a more applicable tool and validate its use – the Standardized Clinical and Functional Remission Criteria (SCFRC). Methods We used a 6-month follow-up study of 203 outpatients from two Moscow centers and another further sample of stable patients from a 1-year controlled trial of atypical versus typical medication. Diagnosis was confirmed by International Classification of Diseases Version 10 (ICD10) criteria and the Mini-International Neuropsychiatric Interview (MINI). Patients were assessed by the Positive and Negative Syndrome Scale, including intensity threshold, and further classified using the Russian domestic remission criteria and the level of social and personal functioning, according to the Personal and Social Performance Scale (PSP). The SCFRC were formulated and were validated by a data reanalysis on the first population sample and on a second independent sample (104 patients) and in an open-label prospective randomized 12-month comparative study of risperidone long-acting injectable (RLAI) versus olanzapine. Results Only 64 of the 203 outpatients (31.5%) initially met the IRC, and 53 patients (26.1%) met the IRC after 6 months, without a change in treatment. Patients who were in remission had episodic and progressive deficit (39.6%), or remittent (15%) paranoid schizophrenia, or schizoaffective disorder (17%). In addition, 105 patients of 139 (51.7%), who did not meet symptomatic IRC, remained stable within the period. Reanalysis of data revealed that 65.5% of the patients met the SCFRC. In the controlled trial, 70% of patients in the RLAI group met the SCFRC and only 19% the IRC. In the routine treatment group, 55.9% met the SCFRC and only 5.7% the IRC. Results of the further independent

  19. Development of Learning Models Based on Problem Solving and Meaningful Learning Standards by Expert Validity for Animal Development Course

    Science.gov (United States)

    Lufri, L.; Fitri, R.; Yogica, R.

    2018-04-01

    The purpose of this study is to produce a learning model based on problem solving and meaningful learning standards by expert assessment or validation for the course of Animal Development. This research is a development research that produce the product in the form of learning model, which consist of sub product, namely: the syntax of learning model and student worksheets. All of these products are standardized through expert validation. The research data is the level of validity of all sub products obtained using questionnaire, filled by validators from various field of expertise (field of study, learning strategy, Bahasa). Data were analysed using descriptive statistics. The result of the research shows that the problem solving and meaningful learning model has been produced. Sub products declared appropriate by expert include the syntax of learning model and student worksheet.

  20. Antibacterial Efficiency of Benzalkonium Chloride Base Disinfectant According To European Standard 13727, Chemical Analysis and Validation Studies

    OpenAIRE

    Yıldırım, Çinel; Çelenk, Veysel

    2018-01-01

    Antibacterial Efficiency of Benzalkonium Chloride Base Disinfectant According To European Standard 13727, Chemical Analysis and Validation Studies This study was aimed to provide principle of the chemical analyses, antibacterial efficiency test and validation procedures of the most commonly used benzalkonium chloride (BAC) base disinfectant as a biocide. Disinfectant which comprised 20 % BAC concentration was used as a prototype product and active substance was verified with chemical analysis...

  1. Application of industry-standard guidelines for the validation of avionics software

    Science.gov (United States)

    Hayhurst, Kelly J.; Shagnea, Anita M.

    1990-01-01

    The application of industry standards to the development of avionics software is discussed, focusing on verification and validation activities. It is pointed out that the procedures that guide the avionics software development and testing process are under increased scrutiny. The DO-178A guidelines, Software Considerations in Airborne Systems and Equipment Certification, are used by the FAA for certifying avionics software. To investigate the effectiveness of the DO-178A guidelines for improving the quality of avionics software, guidance and control software (GCS) is being developed according to the DO-178A development method. It is noted that, due to the extent of the data collection and configuration management procedures, any phase in the life cycle of a GCS implementation can be reconstructed. Hence, a fundamental development and testing platform has been established that is suitable for investigating the adequacy of various software development processes. In particular, the overall effectiveness and efficiency of the development method recommended by the DO-178A guidelines are being closely examined.

  2. New clinical validation method for automated sphygmomanometer: a proposal by Japan ISO-WG for sphygmomanometer standard.

    Science.gov (United States)

    Shirasaki, Osamu; Asou, Yosuke; Takahashi, Yukio

    2007-12-01

    Owing to fast or stepwise cuff deflation, or measuring at places other than the upper arm, the clinical accuracy of most recent automated sphygmomanometers (auto-BPMs) cannot be validated by one-arm simultaneous comparison, which would be the only accurate validation method based on auscultation. Two main alternative methods are provided by current standards, that is, two-arm simultaneous comparison (method 1) and one-arm sequential comparison (method 2); however, the accuracy of these validation methods might not be sufficient to compensate for the suspicious accuracy in lateral blood pressure (BP) differences (LD) and/or BP variations (BPV) between the device and reference readings. Thus, the Japan ISO-WG for sphygmomanometer standards has been studying a new method that might improve validation accuracy (method 3). The purpose of this study is to determine the appropriateness of method 3 by comparing immunity to LD and BPV with those of the current validation methods (methods 1 and 2). The validation accuracy of the above three methods was assessed in human participants [N=120, 45+/-15.3 years (mean+/-SD)]. An oscillometric automated monitor, Omron HEM-762, was used as the tested device. When compared with the others, methods 1 and 3 showed a smaller intra-individual standard deviation of device error (SD1), suggesting their higher reproducibility of validation. The SD1 by method 2 (P=0.004) significantly correlated with the participant's BP, supporting our hypothesis that the increased SD of device error by method 2 is at least partially caused by essential BPV. Method 3 showed a significantly (P=0.0044) smaller interparticipant SD of device error (SD2), suggesting its higher interparticipant consistency of validation. Among the methods of validation of the clinical accuracy of auto-BPMs, method 3, which showed the highest reproducibility and highest interparticipant consistency, can be proposed as being the most appropriate.

  3. Measuring Standards in Primary English: The Validity of PIRLS--A Response to Mary Hilton

    Science.gov (United States)

    Whetton, Chris; Twist, Liz; Sainsbury, Marian

    2007-01-01

    Hilton (2006) criticises the PIRLS (Progress in International Reading Literacy Study) tests and the survey conduct, raising questions about the validity of international surveys of reading. Her criticisms fall into four broad areas: cultural validity, methodological issues, construct validity and the survey in England. However, her criticisms are…

  4. High power, 140 GHz gyrotron

    International Nuclear Information System (INIS)

    Kreischer, K.E.; Temkin, R.J.; Mulligan, W.J.; MacCabe, S.; Chaplya, R.

    1982-01-01

    The design and construction of a pulsed 100 kW, 140 GHz gyrotron is described. Initial gyrotron operation is expected in early 1982. Advances in gyrotron theory have also been carried out in support of this experimental research. The application of gyrotrons to plasma diagnostics is also under investigation. (author)

  5. A dedicated on-line system for the preparation and validation of standard beads in XRF analysis

    International Nuclear Information System (INIS)

    Yamamoto, Yasuyuki; Ogasawara, Noriko; Nakata, Akio; Shoji, Shizuko.

    1995-01-01

    A dedicated on-line system in X-ray Fluorescence (XRF) analysis with glass-bead method was developed in which preparation of standard beads was automated including proper choice of reagents, assignment of bead compositions and validation of the prepared beads. This system features: a. Fundamental Parameter (FP) Method for validation of standard beads. b. An original database of high purity reagents for standards. c. Automatic calculation of suitable composition for each standard bead, by giving a range for each element and the number of standard beads. 1) The calculation is based on random numbers, and makes a random assignment of composition for each bead. 2) The calculation results are automatically stored in a computer as a condition file for quantitative analysis. 3) An amount of a material for a standard mixture is corrected if a valence or a chemical compound for an analysis element is different from that of the standard material in the database. In order to realize these features, many high purity reagents were examined for their purities and other characteristics to test a suitability to use for a standard material, and a software for on-line processings was originally developed. (author)

  6. Chirped Pulse Spectrometer Operating at 200 GHz

    Science.gov (United States)

    Hindle, Francis; Bray, Cédric; Hickson, Kevin; Fontanari, Daniele; Mouelhi, Meriem; Cuisset, Arnaud; Mouret, Gaël; Bocquet, Robin

    2018-01-01

    The combination of electronic sources operating at high frequencies and modern microwave instrumentation has enabled the recent development of chirped pulse spectrometers for the millimetre and THz bands. This type of instrument can operate at high resolution which is particularly suited to gas-phase rotational spectroscopy. The construction of a chirped pulse spectrometer operating at 200 GHz is described in detail while attention is paid to the phase stability and the data accumulation over many cycles. Validation using carbonyl sulphide has allowed the detection limit of the instrument to be established as function of the accumulation. A large number of OCS transitions were identified using a 10-GHz chirped pulse and include the six most abundant isotopologues, the weakest line corresponding to the fundamental R(17) transition of 16O13C33S with a line strength of 4.3 × 10-26 cm-1/(molecule cm-2). The linearity of the system response for different degrees of data accumulation and transition line strength was confirmed over four orders of magnitudes. A simple analysis of the time-domain data was demonstrated to provide the line-broadening coefficient without the need for conversion by a Fourier transform. Finally, the pulse duration is discussed and optimal values are given for both Doppler-limited and collisional regimes.

  7. Design and validation of standardized clinical and functional remission criteria in schizophrenia

    Directory of Open Access Journals (Sweden)

    Mosolov SN

    2014-01-01

    Full Text Available Sergey N Mosolov,1 Andrey V Potapov,1 Uriy V Ushakov,2 Aleksey A Shafarenko,1 Anastasiya B Kostyukova11Department of Mental Disorders Therapy, Moscow Research Institute of Psychiatry, Moscow, Russia; 2Moscow Psychiatric Outpatient Services #21, Moscow, RussiaBackground: International Remission Criteria (IRC for schizophrenia were developed recently by a group of internationally known experts. The IRC detect only 10%–30% of cases and do not cover the diversity of forms and social functioning. Our aim was to design a more applicable tool and validate its use – the Standardized Clinical and Functional Remission Criteria (SCFRC.Methods: We used a 6-month follow-up study of 203 outpatients from two Moscow centers and another further sample of stable patients from a 1-year controlled trial of atypical versus typical medication. Diagnosis was confirmed by International Classification of Diseases Version 10 (ICD10 criteria and the Mini-International Neuropsychiatric Interview (MINI. Patients were assessed by the Positive and Negative Syndrome Scale, including intensity threshold, and further classified using the Russian domestic remission criteria and the level of social and personal functioning, according to the Personal and Social Performance Scale (PSP. The SCFRC were formulated and were validated by a data reanalysis on the first population sample and on a second independent sample (104 patients and in an open-label prospective randomized 12-month comparative study of risperidone long-acting injectable (RLAI versus olanzapine.Results: Only 64 of the 203 outpatients (31.5% initially met the IRC, and 53 patients (26.1% met the IRC after 6 months, without a change in treatment. Patients who were in remission had episodic and progressive deficit (39.6%, or remittent (15% paranoid schizophrenia, or schizoaffective disorder (17%. In addition, 105 patients of 139 (51.7%, who did not meet symptomatic IRC, remained stable within the period. Reanalysis of

  8. Development, validation, and standardization of polymerase chain reaction-based detection of E-coli O157

    DEFF Research Database (Denmark)

    Abdulmawjood, A.; Bulte, M.; Roth, S.

    2004-01-01

    A diagnostic polymerase chain reaction assay was developed for the detection of E. coli O157 as the first part of a multicenter validation and standardization project. The assay is based on amplification of sequences of the rfbE O157 gene and includes an internal amplification control. The select...

  9. Brief International Cognitive Assessment for MS (BICAMS): international standards for validation.

    OpenAIRE

    Benedict, R; Amato, Mp; Boringa, J; Brochet, B; Foley, F; Fredrikson, S; Hamalainen, P; Hartung, H; Krupp, L; Penner, I; Reder, A; Langdon, D.

    2012-01-01

    An international expert consensus committee recently recommended a brief battery of tests for cognitive evaluation in multiple sclerosis. The Brief International Cognitive Assessment for MS (BICAMS) battery includes tests of mental processing speed and memory. Recognizing that resources for validation will vary internationally, the committee identified validation priorities, to facilitate international acceptance of BICAMS. Practical matters pertaining to implementation across different langu...

  10. Validation of the conceptual research utilization scale: an application of the standards for educational and psychological testing in healthcare

    Science.gov (United States)

    2011-01-01

    Background There is a lack of acceptable, reliable, and valid survey instruments to measure conceptual research utilization (CRU). In this study, we investigated the psychometric properties of a newly developed scale (the CRU Scale). Methods We used the Standards for Educational and Psychological Testing as a validation framework to assess four sources of validity evidence: content, response processes, internal structure, and relations to other variables. A panel of nine international research utilization experts performed a formal content validity assessment. To determine response process validity, we conducted a series of one-on-one scale administration sessions with 10 healthcare aides. Internal structure and relations to other variables validity was examined using CRU Scale response data from a sample of 707 healthcare aides working in 30 urban Canadian nursing homes. Principal components analysis and confirmatory factor analyses were conducted to determine internal structure. Relations to other variables were examined using: (1) bivariate correlations; (2) change in mean values of CRU with increasing levels of other kinds of research utilization; and (3) multivariate linear regression. Results Content validity index scores for the five items ranged from 0.55 to 1.00. The principal components analysis predicted a 5-item 1-factor model. This was inconsistent with the findings from the confirmatory factor analysis, which showed best fit for a 4-item 1-factor model. Bivariate associations between CRU and other kinds of research utilization were statistically significant (p use, and longitudinal work to determine CRU Scale sensitivity to change. PMID:21595888

  11. Education Technology Standards Self-Efficacy (ETSSE) Scale: A Validity and Reliability Study

    Science.gov (United States)

    Simsek, Omer; Yazar, Taha

    2016-01-01

    Problem Statement: The educational technology standards for teachers set by the International Society for Technology in Education (the ISTE Standards-T) represent an important framework for using technology effectively in teaching and learning processes. These standards are widely used by universities, educational institutions, and schools. The…

  12. Integrated 60GHz RF beamforming in CMOS

    CERN Document Server

    Yu, Yikun; van Roermund, Arthur H M

    2011-01-01

    ""Integrated 60GHz RF Beamforming in CMOS"" describes new concepts and design techniques that can be used for 60GHz phased array systems. First, general trends and challenges in low-cost high data-rate 60GHz wireless system are studied, and the phased array technique is introduced to improve the system performance. Second, the system requirements of phase shifters are analyzed, and different phased array architectures are compared. Third, the design and implementation of 60GHz passive and active phase shifters in a CMOS technology are presented. Fourth, the integration of 60GHz phase shifters

  13. The jmzQuantML programming interface and validator for the mzQuantML data standard.

    Science.gov (United States)

    Qi, Da; Krishna, Ritesh; Jones, Andrew R

    2014-03-01

    The mzQuantML standard from the HUPO Proteomics Standards Initiative has recently been released, capturing quantitative data about peptides and proteins, following analysis of MS data. We present a Java application programming interface (API) for mzQuantML called jmzQuantML. The API provides robust bridges between Java classes and elements in mzQuantML files and allows random access to any part of the file. The API provides read and write capabilities, and is designed to be embedded in other software packages, enabling mzQuantML support to be added to proteomics software tools (http://code.google.com/p/jmzquantml/). The mzQuantML standard is designed around a multilevel validation system to ensure that files are structurally and semantically correct for different proteomics quantitative techniques. In this article, we also describe a Java software tool (http://code.google.com/p/mzquantml-validator/) for validating mzQuantML files, which is a formal part of the data standard. © 2014 The Authors. Proteomics published by Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Validation of the ISAAC Standardized Questionnaire Used by Schoolchildren from Mexicali, Baja California, Mexico

    OpenAIRE

    Gorozave-Car, Karla; Barraza-Villarreal, Albino; Escamilla-Núñez, Consuelo; Hernandez-Cadena, Leticia; Sanín-Aguirre, Luz Helena; Cortez-Lugo, Marlene; Blanco-Muñoz, J.; Riojas-Rodríguez, Horacio; Moreno-Macias, Hortensia; Romieu, Isabelle

    2013-01-01

    Background. In Mexico, several studies have been conducted under the ISAAC methodology; nevertheless, no validation studies of the ISAAC questionnaire based on objective clinical testing in our country have been published. Aims of the Study. To validate the ISAAC questionnaire, used in a study of prevalence of allergic diseases, based on medical, respiratory, and allergic evaluations of schoolchildren being 11 to 16 years old in Mexicali, Mexico. Material and Methods. We conducted a cross-sec...

  15. Validation of the Australian Midwifery Standards Assessment Tool (AMSAT): A tool to assess midwifery competence.

    Science.gov (United States)

    Sweet, Linda; Bazargan, Maryam; McKellar, Lois; Gray, Joanne; Henderson, Amanda

    2018-02-01

    There is no current validated clinical assessment tool to measure the attainment of midwifery student competence in the midwifery practice setting. The lack of a valid assessment tool has led to a proliferation of tools and inconsistency in assessment of, and feedback on student learning. This research aimed to develop and validate a tool to assess competence of midwifery students in practice-based settings. A mixed-methods approach was used and the study implemented in two phases. Phase one involved the development of the AMSAT tool with qualitative feedback from midwifery academics, midwife assessors of students, and midwifery students. In phase two the newly developed AMSAT tool was piloted across a range of midwifery practice settings and ANOVA was used to compare scores across year levels, with feedback being obtained from assessors. Analysis of 150 AMSAT forms indicate the AMSAT as: reliable (Cronbach alpha greater than 0.9); valid-data extraction loaded predominantly onto one factor; and sensitivity scores indicating level of proficiency increased across the three years. Feedback evaluation forms (n=83) suggest acceptance of this tool for the purpose of both assessing and providing feedback on midwifery student's practice performance and competence. The AMSAT is a valid, reliable and acceptable midwifery assessment tool enables consistent assessment of midwifery student competence. This assists benchmarking across midwifery education programs. Copyright © 2017 Australian College of Midwives. Published by Elsevier Ltd. All rights reserved.

  16. Standardization and validation of a novel and simple method to assess lumbar dural sac size

    International Nuclear Information System (INIS)

    Daniels, M.L.A.; Lowe, J.R.; Roy, P.; Patrone, M.V.; Conyers, J.M.; Fine, J.P.; Knowles, M.R.; Birchard, K.R.

    2015-01-01

    Aim: To develop and validate a simple, reproducible method to assess dural sac size using standard imaging technology. Materials and methods: This study was institutional review board-approved. Two readers, blinded to the diagnoses, measured anterior–posterior (AP) and transverse (TR) dural sac diameter (DSD), and AP vertebral body diameter (VBD) of the lumbar vertebrae using MRI images from 53 control patients with pre-existing MRI examinations, 19 prospectively MRI-imaged healthy controls, and 24 patients with Marfan syndrome with prior MRI or CT lumbar spine imaging. Statistical analysis utilized linear and logistic regression, Pearson correlation, and receiver operating characteristic (ROC) curves. Results: AP-DSD and TR-DSD measurements were reproducible between two readers (r = 0.91 and 0.87, respectively). DSD (L1–L5) was not different between male and female controls in the AP or TR plane (p = 0.43; p = 0.40, respectively), and did not vary by age (p = 0.62; p = 0.25) or height (p = 0.64; p = 0.32). AP-VBD was greater in males versus females (p = 1.5 × 10 −8 ), resulting in a smaller dural sac ratio (DSR) (DSD/VBD) in males (p = 5.8 × 10 −6 ). Marfan patients had larger AP-DSDs and TR-DSDs than controls (p = 5.9 × 10 −9 ; p = 6.5 × 10 −9 , respectively). Compared to DSR, AP-DSD and TR-DSD better discriminate Marfan from control subjects based on area under the curve (AUC) values from unadjusted ROCs (AP-DSD p < 0.01; TR-DSD p = 0.04). Conclusion: Individual vertebrae and L1–L5 (average) AP-DSD and TR-DSD measurements are simple, reliable, and reproducible for quantitating dural sac size without needing to control for gender, age, or height. - Highlights: • DSD (L1-L5) does not differ in the AP or TR plane by gender, height, or age. • AP- and TR-DSD measures correlate well between readers with different experience. • Height is positively correlated to AP-VBD in both males and females. • Varying

  17. Phd study of reliability and validity: One step closer to a standardized music therapy assessment model

    DEFF Research Database (Denmark)

    Jacobsen, Stine Lindahl

    The paper will present a phd study concerning reliability and validity of music therapy assessment model “Assessment of Parenting Competences” (APC) in the area of families with emotionally neglected children. This study had a multiple strategy design with a philosophical base of critical realism...... and pragmatism. The fixed design for this study was a between and within groups design in testing the APCs reliability and validity. The two different groups were parents with neglected children and parents with non-neglected children. The flexible design had a multiple case study strategy specifically...

  18. Performance Analysis of OFDM 60GHz System and SC-FDE 60GHz System

    Directory of Open Access Journals (Sweden)

    Han Xueyan

    2016-01-01

    Full Text Available In this paper, the performance of 60GHz wireless communication system with SC and OFDM is studied, the models of OFDM 60GHz system and SC 60GHz frequency domain equalization (SC-FDE system are established, and the bit error rate (BER performance of OFDM 60GHz system and SC-FDE 60GHz system in 802.15.3c channels is compared. The simulation results show that SC-FDE 60GHz system has a slight advantage over OFDM system in line-of-sight (LOS channels, while OFDM 60GHz system has a slight advantage over SC-FDE system in non-line-of-sight (NLOS channels. For 60GHz system, OFDM 60GHz system has a slight advantage over SC-FDE system in overcoming multipath fading, but the performance of both is close whether in the LOS or NLOS case.

  19. Population Health Metrics Research Consortium gold standard verbal autopsy validation study: design, implementation, and development of analysis datasets

    Directory of Open Access Journals (Sweden)

    Ohno Summer

    2011-08-01

    Full Text Available Abstract Background Verbal autopsy methods are critically important for evaluating the leading causes of death in populations without adequate vital registration systems. With a myriad of analytical and data collection approaches, it is essential to create a high quality validation dataset from different populations to evaluate comparative method performance and make recommendations for future verbal autopsy implementation. This study was undertaken to compile a set of strictly defined gold standard deaths for which verbal autopsies were collected to validate the accuracy of different methods of verbal autopsy cause of death assignment. Methods Data collection was implemented in six sites in four countries: Andhra Pradesh, India; Bohol, Philippines; Dar es Salaam, Tanzania; Mexico City, Mexico; Pemba Island, Tanzania; and Uttar Pradesh, India. The Population Health Metrics Research Consortium (PHMRC developed stringent diagnostic criteria including laboratory, pathology, and medical imaging findings to identify gold standard deaths in health facilities as well as an enhanced verbal autopsy instrument based on World Health Organization (WHO standards. A cause list was constructed based on the WHO Global Burden of Disease estimates of the leading causes of death, potential to identify unique signs and symptoms, and the likely existence of sufficient medical technology to ascertain gold standard cases. Blinded verbal autopsies were collected on all gold standard deaths. Results Over 12,000 verbal autopsies on deaths with gold standard diagnoses were collected (7,836 adults, 2,075 children, 1,629 neonates, and 1,002 stillbirths. Difficulties in finding sufficient cases to meet gold standard criteria as well as problems with misclassification for certain causes meant that the target list of causes for analysis was reduced to 34 for adults, 21 for children, and 10 for neonates, excluding stillbirths. To ensure strict independence for the validation of

  20. Validation of a Standardized Multiple-Choice Multicultural Competence Test: Implications for Training, Assessment, and Practice

    Science.gov (United States)

    Gillem, Angela R.; Bartoli, Eleonora; Bertsch, Kristin N.; McCarthy, Maureen A.; Constant, Kerra; Marrero-Meisky, Sheila; Robbins, Steven J.; Bellamy, Scarlett

    2016-01-01

    The Multicultural Counseling and Psychotherapy Test (MCPT), a measure of multicultural counseling competence (MCC), was validated in 2 phases. In Phase 1, the authors administered 451 test items derived from multicultural guidelines in counseling and psychology to 32 multicultural experts and 30 nonexperts. In Phase 2, the authors administered the…

  1. Training to Support Standardization and Improvement of Safety I and C Related Verification and Validation Activities

    Energy Technology Data Exchange (ETDEWEB)

    Ammon, G.; Schoenfelder, C.

    2014-07-01

    In recent years AREVA has conducted several measures to enhance the effectiveness of safety I and C related verification and validation activities within nuclear power plant (NPP) new build as well as modernization projects, thereby further strengthening its commitment to achieving the highest level of safety in nuclear facilities. (Author)

  2. 41 CFR 60-3.14 - Technical standards for validity studies.

    Science.gov (United States)

    2010-07-01

    ..., such as intelligence, aptitude, personality, commonsense, judgment, leadership, and spatial ability.... (6) Prior training or experience. A requirement for or evaluation of specific prior training or experience based on content validity, including a specification of level or amount of training or experience...

  3. STANDARDIZATION AND VALIDATION OF METHODS FOR ENUMERATION OF FECAL COLIFORM AND SALMONELLA IN BIOSOLIDS

    Science.gov (United States)

    Current federal regulations require monitoring for fecal coliforms or Salmonella in biosolids destined for land application. Methods used for analysis of fecal coliforms and Salmonella were reviewed and a standard protocol was developed. The protocols were then evaluated by testi...

  4. Validation and standardization of the Generalized Anxiety Disorder Screener (GAD-7) in the general population.

    Science.gov (United States)

    Löwe, Bernd; Decker, Oliver; Müller, Stefanie; Brähler, Elmar; Schellberg, Dieter; Herzog, Wolfgang; Herzberg, Philipp Yorck

    2008-03-01

    The 7-item Generalized Anxiety Disorder Scale (GAD-7) is a practical self-report anxiety questionnaire that proved valid in primary care. However, the GAD-7 was not yet validated in the general population and thus far, normative data are not available. To investigate reliability, construct validity, and factorial validity of the GAD-7 in the general population and to generate normative data. Nationally representative face-to-face household survey conducted in Germany between May 5 and June 8, 2006. Five thousand thirty subjects (53.6% female) with a mean age (SD) of 48.4 (18.0) years. The survey questionnaire included the GAD-7, the 2-item depression module from the Patient Health Questionnaire (PHQ-2), the Rosenberg Self-Esteem Scale, and demographic characteristics. Confirmatory factor analyses substantiated the 1-dimensional structure of the GAD-7 and its factorial invariance for gender and age. Internal consistency was identical across all subgroups (alpha = 0.89). Intercorrelations with the PHQ-2 and the Rosenberg Self-Esteem Scale were r = 0.64 (P < 0.001) and r = -0.43 (P < 0.001), respectively. As expected, women had significantly higher mean (SD) GAD-7 anxiety scores compared with men [3.2 (3.5) vs. 2.7 (3.2); P < 0.001]. Normative data for the GAD-7 were generated for both genders and different age levels. Approximately 5% of subjects had GAD-7 scores of 10 or greater, and 1% had GAD-7 scores of 15 or greater. Evidence supports reliability and validity of the GAD-7 as a measure of anxiety in the general population. The normative data provided in this study can be used to compare a subject's GAD-7 score with those determined from a general population reference group.

  5. An investigation into the validity of cervical spine motion palpation using subjects with congenital block vertebrae as a 'gold standard'

    Directory of Open Access Journals (Sweden)

    Peterson Cynthia K

    2004-06-01

    Full Text Available Abstract Background Although the effectiveness of manipulative therapy for treating back and neck pain has been demonstrated, the validity of many of the procedures used to detect joint dysfunction has not been confirmed. Practitioners of manual medicine frequently employ motion palpation as a diagnostic tool, despite conflicting evidence regarding its utility and reliability. The introduction of various spinal models with artificially introduced 'fixations' as an attempt to introduce a 'gold standard' has met with frustration and frequent mechanical failure. Because direct comparison against a 'gold standard' allows the validity, specificity and sensitivity of a test to be calculated, the identification of a realistic 'gold standard' against which motion palpation can be evaluated is essential. The objective of this study was to introduce a new, realistic, 'gold standard', the congenital block vertebra (CBV to assess the validity of motion palpation in detecting a true fixation. Methods Twenty fourth year chiropractic students examined the cervical spines of three subjects with single level congenital block vertebrae, using two commonly employed motion palpation tests. The examiners, who were blinded to the presence of congenital block vertebrae, were asked to identify the most hypomobile segment(s. The congenital block segments included two subjects with fusion at the C2–3 level and one with fusion at C5-6. Exclusion criteria included subjects who were frankly symptomatic, had moderate or severe degenerative changes in their cervical spines, or displayed signs of cervical instability. Spinal levels were marked on the subject's skin overlying the facet joints from C1 to C7 bilaterally and the motion segments were then marked alphabetically with 'A' corresponding to C1-2. Kappa coefficients (K were calculated to determine the validity of motion palpation to detect the congenitally fused segments as the 'most hypomobile' segments. Sensitivity

  6. Quantitative determination and validation of octreotide acetate using 1 H-NMR spectroscopy with internal standard method.

    Science.gov (United States)

    Yu, Chen; Zhang, Qian; Xu, Peng-Yao; Bai, Yin; Shen, Wen-Bin; Di, Bin; Su, Meng-Xiang

    2018-01-01

    Quantitative nuclear magnetic resonance (qNMR) is a well-established technique in quantitative analysis. We presented a validated 1 H-qNMR method for assay of octreotide acetate, a kind of cyclic octopeptide. Deuterium oxide was used to remove the undesired exchangeable peaks, which was referred to as proton exchange, in order to make the quantitative signals isolated in the crowded spectrum of the peptide and ensure precise quantitative analysis. Gemcitabine hydrochloride was chosen as the suitable internal standard. Experimental conditions, including relaxation delay time, the numbers of scans, and pulse angle, were optimized first. Then method validation was carried out in terms of selectivity, stability, linearity, precision, and robustness. The assay result was compared with that by means of high performance liquid chromatography, which is provided by Chinese Pharmacopoeia. The statistical F test, Student's t test, and nonparametric test at 95% confidence level indicate that there was no significant difference between these two methods. qNMR is a simple and accurate quantitative tool with no need for specific corresponding reference standards. It has the potential of the quantitative analysis of other peptide drugs and standardization of the corresponding reference standards. Copyright © 2017 John Wiley & Sons, Ltd.

  7. Validation of standard operating procedures in a multicenter retrospective study to identify -omics biomarkers for chronic low back pain.

    Directory of Open Access Journals (Sweden)

    Concetta Dagostino

    Full Text Available Chronic low back pain (CLBP is one of the most common medical conditions, ranking as the greatest contributor to global disability and accounting for huge societal costs based on the Global Burden of Disease 2010 study. Large genetic and -omics studies provide a promising avenue for the screening, development and validation of biomarkers useful for personalized diagnosis and treatment (precision medicine. Multicentre studies are needed for such an effort, and a standardized and homogeneous approach is vital for recruitment of large numbers of participants among different centres (clinical and laboratories to obtain robust and reproducible results. To date, no validated standard operating procedures (SOPs for genetic/-omics studies in chronic pain have been developed. In this study, we validated an SOP model that will be used in the multicentre (5 centres retrospective "PainOmics" study, funded by the European Community in the 7th Framework Programme, which aims to develop new biomarkers for CLBP through three different -omics approaches: genomics, glycomics and activomics. The SOPs describe the specific procedures for (1 blood collection, (2 sample processing and storage, (3 shipping details and (4 cross-check testing and validation before assays that all the centres involved in the study have to follow. Multivariate analysis revealed the absolute specificity and homogeneity of the samples collected by the five centres for all genetics, glycomics and activomics analyses. The SOPs used in our multicenter study have been validated. Hence, they could represent an innovative tool for the correct management and collection of reliable samples in other large-omics-based multicenter studies.

  8. Design and validation of a standards-based science teacher efficacy instrument

    Science.gov (United States)

    Kerr, Patricia Reda

    National standards for K--12 science education address all aspects of science education, with their main emphasis on curriculum---both science subject matter and the process involved in doing science. Standards for science teacher education programs have been developing along a parallel plane, as is self-efficacy research involving classroom teachers. Generally, studies about efficacy have been dichotomous---basing the theoretical underpinnings on the work of either Rotter's Locus of Control theory or on Bandura's explanations of efficacy beliefs and outcome expectancy. This study brings all three threads together---K--12 science standards, teacher education standards, and efficacy beliefs---in an instrument designed to measure science teacher efficacy with items based on identified critical attributes of standards-based science teaching and learning. Based on Bandura's explanation of efficacy being task-specific and having outcome expectancy, a developmental, systematic progression from standards-based strategies and activities to tasks to critical attributes was used to craft items for a standards-based science teacher efficacy instrument. Demographic questions related to school characteristics, teacher characteristics, preservice background, science teaching experience, and post-certification professional development were included in the instrument. The instrument was completed by 102 middle level science teachers, with complete data for 87 teachers. A principal components analysis of the science teachers' responses to the instrument resulted in two components: Standards-Based Science Teacher Efficacy: Beliefs About Teaching (BAT, reliability = .92) and Standards-Based Science Teacher Efficacy: Beliefs About Student Achievement (BASA, reliability = .82). Variables that were characteristic of professional development activities, science content preparation, and school environment were identified as members of the sets of variables predicting the BAT and BASA

  9. Vehicle to Grid Communication Standards Development, Testing and Validation - Status Report

    Energy Technology Data Exchange (ETDEWEB)

    Gowri, Krishnan; Pratt, Richard M.; Tuffner, Francis K.; Kintner-Meyer, Michael CW

    2011-09-01

    In the US, more than 10,000 electric vehicles (EV) have been delivered to consumers during the first three quarters of 2011. A large majority of these vehicles are battery electric, often requiring 220 volt charging. Though the vehicle manufacturers and charging station manufacturers have provided consumers options for charging preferences, there are no existing communications between consumers and the utilities to manage the charging demand. There is also wide variation between manufacturers in their approach to support vehicle charging. There are in-vehicle networks, charging station networks, utility networks each using either cellular, Wi-Fi, ZigBee or other proprietary communication technology with no standards currently available for interoperability. The current situation of ad-hoc solutions is a major barrier to the wide adoption of electric vehicles. SAE, the International Standards Organization/International Electrotechnical Commission (ISO/IEC), ANSI, National Institute of Standards and Technology (NIST) and several industrial organizations are working towards the development of interoperability standards. PNNL has participated in the development and testing of these standards in an effort to accelerate the adoption and development of communication modules.

  10. Introductory Guide for Conducting ASVAB Validation/Standards Studies in the U.S. Navy

    Science.gov (United States)

    2014-10-16

    for navigator training, that job knowledge component of the AFOQT was not specific enough to provide incremental validity. Thorndike (1985, 1986...University Press. Thorndike , R. L. (1985). The central role of general ability in prediction. Multivariate Behavioral Research, 20, 241-254. Thorndike , R...variance that is due to the construct of interest; cf. Thorndike , 1949). In addition, the interpretation of the composite criterion is questionable if

  11. Technical Guidance for Conducting ASVAB Validation/Standards Studies in the U.S. Navy

    Science.gov (United States)

    2015-02-01

    a real life example, Thorndike (1949) provided extraordinary validity results for 1,036 men in pilot training for the U.S. Army Air Force during...scores received in the pilot training course. Thorndike also computed the correlation for only the 136 men who would have qualified for pilot training...xyr = .18. The importance of correcting for incidental selection as well as explicit selection can be seen in the correlations presented by Thorndike

  12. Protocol for Usability Testing and Validation of the ISO Draft International Standard 19223 for Lung Ventilators

    Science.gov (United States)

    2017-01-01

    Background Clinicians, such as respiratory therapists and physicians, are often required to set up pieces of medical equipment that use inconsistent terminology. Current lung ventilator terminology that is used by different manufacturers contributes to the risk of usage errors, and in turn the risk of ventilator-associated lung injuries and other conditions. Human factors and communication issues are often associated with ventilator-related sentinel events, and inconsistent ventilator terminology compounds these issues. This paper describes our proposed protocol, which will be implemented at the University of Waterloo, Canada when this project is externally funded. Objective We propose to determine whether a standardized vocabulary improves the ease of use, safety, and utility as it relates to the usability of medical devices, compared to legacy medical devices from multiple manufacturers, which use different terms. Methods We hypothesize that usage errors by clinicians will be lower when standardization is consistently applied by all manufacturers. The proposed study will experimentally examine the impact of standardized nomenclature on performance declines in the use of an unfamiliar ventilator product in clinically relevant scenarios. Participants will be respiratory therapy practitioners and trainees, and we propose studying approximately 60 participants. Results The work reported here is in the proposal phase. Once the protocol is implemented, we will report the results in a follow-up paper. Conclusions The proposed study will help us better understand the effects of standardization on medical device usability. The study will also help identify any terms in the International Organization for Standardization (ISO) Draft International Standard (DIS) 19223 that may be associated with recurrent errors. Amendments to the standard will be proposed if recurrent errors are identified. This report contributes a protocol that can be used to assess the effect of

  13. 154 GHz collective Thomson scattering in LHD

    Science.gov (United States)

    Tanaka, K.; Nishiura, M.; Kubo, S.; Shimozuma, T.; Saito, T.; Moseev, D.; Abramovic, I.

    2018-01-01

    Collective Thomson scattering (CTS) was developed by using a 154 GHz gyrotron, and the first data has been obtained. Already, 77 GHz CTS has worked successfully. However, in order to access higher density region, 154 GHz option enhances the usability that reduces the refraction effect, which deteriorates in the local measurements. The system in the down converted frequency was almost identical to the system for 77 GHz. Probing beam, a notch filter, a mixer, and a local oscillator in the receiver system for 77 GHz option were replaced to those for the 154 GHz option. 154 GHz gyrotron was originally prepared for the second harmonic electron cyclotron heating (ECRH) at 2.75 T. However, scattering signal was masked by the second harmonic electron cyclotron emission (ECE) at 2.75 T. Therefore, 154 GHz CTS was operated at 1.375 T with fourth harmonic ECE, and an acceptable signal to noise ratio was obtained. There is a signature of fast ion components with neutral beam (NB) injection. In addition, the CTS spectrum became broader in hydrogen discharge than in deuterium discharge, as the theoretical CTS spectrum expects. This observation indicates a possibility to identify ion species ratio by the 154 GHz CTS diagnostic.

  14. Puerto Rican understandings of child disability: methods for the cultural validation of standardized measures of child health.

    Science.gov (United States)

    Gannotti, Mary E; Handwerker, W Penn

    2002-12-01

    Validating the cultural context of health is important for obtaining accurate and useful information from standardized measures of child health adapted for cross-cultural applications. This paper describes the application of ethnographic triangulation for cultural validation of a measure of childhood disability, the Pediatric Evaluation of Disability Inventory (PEDI) for use with children living in Puerto Rico. The key concepts include macro-level forces such as geography, demography, and economics, specific activities children performed and their key social interactions, beliefs, attitudes, emotions, and patterns of behavior surrounding independence in children and childhood disability, as well as the definition of childhood disability. Methods utilize principal components analysis to establish the validity of cultural concepts and multiple regression analysis to identify intracultural variation. Findings suggest culturally specific modifications to the PEDI, provide contextual information for informed interpretation of test scores, and point to the need to re-standardize normative values for use with Puerto Rican children. Without this type of information, Puerto Rican children may appear more disabled than expected for their level of impairment or not to be making improvements in functional status. The methods also allow for cultural boundaries to be quantitatively established, rather than presupposed. Copyright 2002 Elsevier Science Ltd.

  15. Concurrent Validity of Two Standardized Measures of Gross Motor Function in Young Children with Autism Spectrum Disorder.

    Science.gov (United States)

    Holloway, Jamie M; Long, Toby; Biasini, Fred

    2018-04-02

    This study provides information on how two standardized measures based on different theoretical frameworks can be used in collecting information on motor development and performance in 4- and 5-year-olds with autism spectrum disorder (ASD). The purpose of the study was to determine the concurrent validity of the Miller Function and Participation Scales (M-FUN) with the Peabody Developmental Motor Scales, Second Edition (PDMS-2) in young children with ASD. The gross motor sections of the PDMS-2 and the M-FUN were administered to 22 children with ASD between the ages of 48 and 71 months. Concurrent validity between overall motor scores and agreement in identification of motor delay were assessed. A very strong correlation (Pearson's r =.851) was found between the M-FUN scale scores and the PDMS-2 gross motor quotients (GMQs). Strong agreement in identification of children with average motor skills and delayed motor skills at 1.5 standard deviations below the mean was also found. This study supports the concurrent validity of the M-FUN with the PDMS-2 for young children with ASD. While both tests provide information regarding motor delay, the M-FUN may provide additional information regarding the neurological profile of the child.

  16. The Development and Validation of the Test Of Astronomy STandards (TOAST)

    Science.gov (United States)

    Slater, Stephanie J.

    2014-01-01

    The Test Of Astronomy STandards (TOAST) is a comprehensive assessment instrument designed to measure students' general astronomy content knowledge. Built upon the research embedded within a generation of astronomy assessments designed to measure single concepts, the TOAST is appropriate to measure across an entire astronomy course. The TOAST's…

  17. Structured surface reflector design for oblique incidence beam splitter at 610 GHz

    OpenAIRE

    Defrance , Fabien; Casaletti , Massimiliano; Sarrazin , Julien; Wiedner , Martina; Gibson , Hugh; Gay , Gregory; Lefevre , Roland; Delorme , Yan

    2016-01-01

    International audience; An iterative alternate projection-based algorithm is developed to design structured surface reflectors to operate as beam splitters at GHz and THz frequencies. To validate the method, a surface profile is determined to achieve a reflector at 610 GHz that generates four equal-intensity beams towards desired directions of ±12.6° with respect to the specular reflection axis. A prototype is fabricated and the beam splitter behavior is experimentally demonstrated. Measureme...

  18. Standard assessments of frailty are validated predictors of mortality in hospitalized patients with cirrhosis.

    LENUS (Irish Health Repository)

    Tapper, Elliot B

    2015-04-04

    The risk of morbidity and mortality for hospitalized patients with cirrhosis is high and incompletely captured by conventional indices. We sought to evaluate the predictive role of frailty in an observational cohort study of inpatients with decompensated cirrhosis between 2010 and 2013. The primary outcome was 90-day mortality. Secondary outcomes included discharge to a rehabilitation hospital, 30-day readmission, and length of stay. Frailty was assessed with three metrics: activities of daily living (ADL), the Braden Scale, and the Morse fall risk score. A predictive model was validated by randomly dividing the population into training and validation cohorts: 734 patients were admitted 1358 times in the study period. The overall 90-day mortality was 18.3%. The 30-day readmission rate was 26.6%, and the rate of discharge to a rehabilitation facility was 14.3%. Adjusting for sex, age, Model for End-Stage Liver Disease, sodium, and Charlson index, the odds ratio for the effect of an ADL score of less than 12 of 15 on mortality is 1.83 (95% confidence interval [CI] 1.05-3.20). A predictive model for 90-day mortality including ADL and Braden Scale yielded C statistics of 0.83 (95% CI 0.80-0.86) and 0.77 (95% CI 0.71-0.83) in the derivation and validation cohorts, respectively. Discharge to a rehabilitation hospital is predicted by both the ADL (<12) and Braden Scale (<16), with respective adjusted odds ratios of 3.78 (95% CI 1.97-7.29) and 6.23 (95% CI 2.53-15.4). Length of stay was associated with the Braden Scale (<16) (hazard ratio = 0.63, 95% CI 0.44-0.91). No frailty measure was associated with 30-day readmission.

  19. Validation of the ASSERT subchannel code: Prediction of critical heat flux in standard and nonstandard CANDU bundle geometries

    International Nuclear Information System (INIS)

    Carver, M.B.; Kiteley, J.C.; Zhou, R.Q.N.; Junop, S.V.; Rowe, D.S.

    1995-01-01

    The ASSERT code has been developed to address the three-dimensional computation of flow and phase distribution and fuel element surface temperatures within the horizontal subchannels of Canada uranium deuterium (CANDU) pressurized heavy water reactor fuel channels and to provide a detailed prediction of critical heat flux (CHF) distribution throughout the bundle. The ASSERT subchannel code has been validated extensively against a wide repertoire of experiments; its combination of three-dimensional prediction of local flow conditions with a comprehensive method of predicting CHF at these local conditions makes it a unique tool for predicting CHF for situations outside the existing experimental database. In particular, ASSERT is an appropriate tool to systematically investigate CHF under conditions of local geometric variations, such as pressure tube creep and fuel element strain. The numerical methodology used in ASSERT, the constitutive relationships incorporated, and the CHF assessment methodology are discussed. The evolutionary validation plan is also discussed and early validation exercises are summarized. More recent validation exercises in standard and nonstandard geometries are emphasized

  20. [Reliability and validity of the standardized Mini Mental State Examination in the diagnosis of mild dementia in Turkish population].

    Science.gov (United States)

    Güngen, Can; Ertan, Turan; Eker, Engin; Yaşar, Resmiye; Engin, Funda

    2002-01-01

    Reliability and validity of the Mini Mental State Examination in differentiating mild dementia from normal controls in Turkish population. The Standardized Mini Mental State Examination (SMMSE) and its instruction were translated into Turkish. A total of 212 subjects with mean age of 77 +/- 6, were recruited for the study. 71 were diagnosed to be demented and 141 were evaluated as normal controls. The scale total score was analysed for discriminant validity using Student's t-test. Sensitivity, specificity, positive and negative predictive values and kappa score were calculated for all of the scores between 18 and 29. Kappa value was calculated for the comparison of the dementia diagnosis between the two investigators using the best cut off score obtained in the analysis above. Statistical analysis revealed that the Turkish version of the SMMSE has high discriminant validity and interrater reliability in the diagnosis of mild dementia. The cut off score 23/24 was found to have the highest sensitivity (0.91), specificity (0.95), positive and negative predictive values (0.90 and 0.95) and kappa score (0.86). Interrater reliability analysis showed high correlation (r:0.99) and kappa value (0.92). The results of this study showed that the Turkish version of the SMMSE has high reliability and validity for the diagnosis of mild dementia in Turkish population.

  1. Establishment and intra-/inter-laboratory validation of a standard protocol of reactive oxygen species assay for chemical photosafety evaluation.

    Science.gov (United States)

    Onoue, Satomi; Hosoi, Kazuhiro; Wakuri, Shinobu; Iwase, Yumiko; Yamamoto, Toshinobu; Matsuoka, Naoko; Nakamura, Kazuichi; Toda, Tsuguto; Takagi, Hironori; Osaki, Naoto; Matsumoto, Yasuhiro; Kawakami, Satoru; Seto, Yoshiki; Kato, Masashi; Yamada, Shizuo; Ohno, Yasuo; Kojima, Hajime

    2013-11-01

    A reactive oxygen species (ROS) assay was previously developed for photosafety evaluation of pharmaceuticals, and the present multi-center study aimed to establish and validate a standard protocol for ROS assay. In three participating laboratories, two standards and 42 coded chemicals, including 23 phototoxins and 19 nonphototoxic drugs/chemicals, were assessed by the ROS assay according to the standardized protocol. Most phototoxins tended to generate singlet oxygen and/or superoxide under UV-vis exposure, but nonphototoxic chemicals were less photoreactive. In the ROS assay on quinine (200 µm), a typical phototoxic drug, the intra- and inter-day precisions (coefficient of variation; CV) were found to be 1.5-7.4% and 1.7-9.3%, respectively. The inter-laboratory CV for quinine averaged 15.4% for singlet oxygen and 17.0% for superoxide. The ROS assay on 42 coded chemicals (200 µm) provided no false negative predictions upon previously defined criteria as compared with the in vitro/in vivo phototoxicity, although several false positives appeared. Outcomes from the validation study were indicative of satisfactory transferability, intra- and inter-laboratory variability, and predictive capacity of the ROS assay. Copyright © 2012 John Wiley & Sons, Ltd.

  2. Entanglement swapping of a GHZ state via a GHZ-like state

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, Chia-Wei; Hwang, Tzonelih, E-mail: hwangtl@ismail.csie.ncku.edu.t [National Cheng Kung University, Department of Computer Science and Information Engineering, No. 1 Ta-Hsueh Road, Tainan City 701, Taiwan (China)

    2011-10-15

    This study uses the Greenberger-Horne-Zeilinger (GHZ)-like state |G>= 1/2 (|001>+|010>+|100>+|111>) to establish an entanglement swapping protocol on a pure GHZ state. A quantum circuit is proposed to assist in teleporting the entanglement of the pure GHZ state. Furthermore, on the basis of the generation of the GHZ-like state, an improved protocol to reduce the number of transmitted photons required in the process of entanglement swapping is proposed.

  3. Design of a Competency Evaluation Model for Clinical Nursing Practicum, Based on Standardized Language Systems: Psychometric Validation Study.

    Science.gov (United States)

    Iglesias-Parra, Maria Rosa; García-Guerrero, Alfonso; García-Mayor, Silvia; Kaknani-Uttumchandani, Shakira; León-Campos, Álvaro; Morales-Asencio, José Miguel

    2015-07-01

    To develop an evaluation system of clinical competencies for the practicum of nursing students based on the Nursing Interventions Classification (NIC). Psychometric validation study: the first two phases addressed definition and content validation, and the third phase consisted of a cross-sectional study for analyzing reliability. The study population was undergraduate nursing students and clinical tutors. Through the Delphi technique, 26 competencies and 91 interventions were isolated. Cronbach's α was 0.96. Factor analysis yielded 18 factors that explained 68.82% of the variance. Overall inter-item correlation was 0.26, and total-item correlation ranged between 0.66 and 0.19. A competency system for the nursing practicum, structured on the NIC, is a reliable method for assessing and evaluating clinical competencies. Further evaluations in other contexts are needed. The availability of standardized language systems in the nursing discipline supposes an ideal framework to develop the nursing curricula. © 2015 Sigma Theta Tau International.

  4. Standardized Water Budget Index and Validation in Drought Estimation of Haihe River Basin, North China

    Directory of Open Access Journals (Sweden)

    Shaohua Liu

    2016-01-01

    Full Text Available The physical-based drought indices such as the self-calibrated Palmer Drought Severity Index (sc-PDSI with the fixed time scale is inadequate for the multiscalar drought assessment, and the multiscalar drought indices including Standardized Precipitation Index (SPI, Reconnaissance Drought Index (RDI, and Standardized Precipitation Evapotranspiration Index (SPEI based on the meteorological factors are lack of physical mechanism and cannot depict the actual water budget. To fill this gap, the Standardized Water Budget Index (SWBI is constructed based on the difference between areal precipitation and actual evapotranspiration (AET, which can describe the actual water budget but also assess the drought at multiple time scales. Then, sc-PDSI was taken as the reference drought index to compare with multiscalar drought indices at different time scale in Haihe River basin. The result shows that SWBI correlates better with sc-PDSI and the RMSE of SWBI is less than other multiscalar drought indices. In addition, all of drought indices show a decreasing trend in Haihe River Basin, possibly due to the decreasing precipitation from 1961 to 2010. The decreasing trends of SWBI were significant and consistent at all the time scales, while the decreasing trends of other multiscalar drought indices are insignificant at time scale less than 3 months.

  5. Standard problem exercise to validate criticality codes for spent LWR fuel transport container calculations

    International Nuclear Information System (INIS)

    Whitesides, G.H.; Stephens, M.E.

    1984-01-01

    During the past two years, a Working Group established by the Organization for Economic Co-Operation and Development's Nuclear Energy Agency (OECD-NEA) has been developing a set of criticality benchmark problems which could be used to help establish the validity of criticality safety computer programs and their associated nuclear data for calculation of ksub(eff) for spent light water reactor (LWR) fuel transport containers. The basic goal of this effort was to identify a set of actual critical experiments which would contain the various material and geometric properties present in spent LWR transport contrainers. These data, when used by the various computational methods, are intended to demonstrate the ability of each method to accurately reproduce the experimentally measured ksub(eff) for the parameters under consideration

  6. Structural Design of the DTU-ESA MM-Wave Validation Standard Antenna

    DEFF Research Database (Denmark)

    Branner, Kim; Berring, Peter; Markussen, Christen Malte

    2015-01-01

    A new specially designed antenna to be used for inter-comparisons and validation of antenna test facilities is under development in cooperation between DTU and TICRA under a contract from the European Space Agency. The antenna is designed to be extremely thermally and mechanically stable...... in the range of temperatures 20±5°C under arbitrary orientation in the gravity field. The antenna has a characteristic length of approximately 500mm. And in order to obtain very low measuring error, the allowable deformations of the reflector and feeds are down to 2.5μm. The antenna is modelled structurally...... is connected via a glued contact formulation in MSC.MARC. Because of the size and the complexity of the model a computer cluster is applied to solve the analyses. This paper describes the structural solution to meet these extremely strict stability requirements and the structural analyses done in order...

  7. Residual standard deviation: Validation of a new measure of dual-task cost in below-knee prosthesis users.

    Science.gov (United States)

    Howard, Charla L; Wallace, Chris; Abbas, James; Stokic, Dobrivoje S

    2017-01-01

    We developed and evaluated properties of a new measure of variability in stride length and cadence, termed residual standard deviation (RSD). To calculate RSD, stride length and cadence are regressed against velocity to derive the best fit line from which the variability (SD) of the distance between the actual and predicted data points is calculated. We examined construct, concurrent, and discriminative validity of RSD using dual-task paradigm in 14 below-knee prosthesis users and 13 age- and education-matched controls. Subjects walked first over an electronic walkway while performing separately a serial subtraction and backwards spelling task, and then at self-selected slow, normal, and fast speeds used to derive the best fit line for stride length and cadence against velocity. Construct validity was demonstrated by significantly greater increase in RSD during dual-task gait in prosthesis users than controls (group-by-condition interaction, stride length p=0.0006, cadence p=0.009). Concurrent validity was established against coefficient of variation (CV) by moderate-to-high correlations (r=0.50-0.87) between dual-task cost RSD and dual-task cost CV for both stride length and cadence in prosthesis users and controls. Discriminative validity was documented by the ability of dual-task cost calculated from RSD to effectively differentiate prosthesis users from controls (area under the receiver operating characteristic curve, stride length 0.863, p=0.001, cadence 0.808, p=0.007), which was better than the ability of dual-task cost CV (0.692, 0.648, respectively, not significant). These results validate RSD as a new measure of variability in below-knee prosthesis users. Future studies should include larger cohorts and other populations to ascertain its generalizability. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Development and validation of a HPLC method for standardization of herbal and commercial extracts of Myrcia uniflora

    Directory of Open Access Journals (Sweden)

    Andrea N. de L. Batista

    2011-06-01

    Full Text Available Myrcia uniflora Barb. Rodr., Myrtaceae, popularly known as "pedra-hume-caá" in Brazil, is sold as dry extracts in capsules or as tinctures for the treatment of diabetes mellitus. Previous phytochemical studies on this species described the occurrence of the flavonoids mearnsitrin and myricitrin. In the present study, the chromatographic profiles of M. uniflora leaves and commercial extracts were determined using HPLC-PAD. Myricitrin was used as an external standard in the development and validation of the HPLC method. The proposed method is simple, rapid and reliable and can be successfully applied in industry for standardization of herbs and phytomedicines commercialised in Brazil as "pedra-hume-caá".

  9. Development and validation of a HPLC method for standardization of herbal and commercial extracts of Myrcia uniflora

    Directory of Open Access Journals (Sweden)

    Andrea N. de L. Batista

    2011-04-01

    Full Text Available Myrcia uniflora Barb. Rodr., Myrtaceae, popularly known as "pedra-hume-caá" in Brazil, is sold as dry extracts in capsules or as tinctures for the treatment of diabetes mellitus. Previous phytochemical studies on this species described the occurrence of the flavonoids mearnsitrin and myricitrin. In the present study, the chromatographic profiles of M. uniflora leaves and commercial extracts were determined using HPLC-PAD. Myricitrin was used as an external standard in the development and validation of the HPLC method. The proposed method is simple, rapid and reliable and can be successfully applied in industry for standardization of herbs and phytomedicines commercialised in Brazil as "pedra-hume-caá".

  10. 47 CFR 25.250 - Sharing between NGSO MSS Feeder links Earth Stations in the 19.3-19.7 GHz and 29.1-29.5 GHz Bands.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Sharing between NGSO MSS Feeder links Earth Stations in the 19.3-19.7 GHz and 29.1-29.5 GHz Bands. 25.250 Section 25.250 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES SATELLITE COMMUNICATIONS Technical Standards § 25...

  11. Electric Vehicle Communications Standards Testing and Validation - Phase II: SAE J2931/1

    Energy Technology Data Exchange (ETDEWEB)

    Pratt, Richard M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Gowri, Krishnan [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2013-01-15

    Vehicle to grid communication standards enable interoperability among vehicles, charging stations and utility providers and provide the capability to implement charge management. Several standards initiatives by the Society of Automobile Engineers (SAE), International Standards Organization and International Electrotechnical Commission (ISO/IEC), and ZigBee/HomePlug Alliance are developing requirements for communication messages and protocols. Recent work by the Electric Power Research Institute (EPRI) in collaboration with SAE and automobile manufacturers has identified vehicle to grid communication performance requirements and developed a test plan as part of SAE J2931/1 committee work. This laboratory test plan was approved by the SAE J2931/1 committee and included test configurations, test methods, and performance requirements to verify reliability, robustness, repeatability, maximum communication distance, and authentication features of power line carrier (PLC) communication modules at the internet protocol layer level. The goal of the testing effort was to select a communication technology that would enable automobile manufacturers to begin the development and implementation process. The EPRI/Argonne National Laboratory (ANL)/Pacific Northwest National Laboratory (PNNL) testing teams divided the testing so that results for each test could be presented by two teams, performing the tests independently. The PNNL team performed narrowband PLC testing including the Texas Instruments (TI) Concerto, Ariane Controls AC-CPM1, and the MAXIM Tahoe 2 evaluation boards. The scope of testing was limited to measuring the vendor systems communication performance between Electric Vehicle Support Equipment (EVSE) and plug-in electric vehicles (PEV). The testing scope did not address PEV’s CAN bus to PLC or PLC to EVSE (Wi-Fi, cellular, PLC Mains, etc.) communication integration. In particular, no evaluation was performed to delineate the effort needed to translate the IPv6

  12. Validation of a standardized mapping system of the hip joint for radial MRA sequencing

    International Nuclear Information System (INIS)

    Klenke, Frank M.; Hoffmann, Daniel B.; Cross, Brian J.; Siebenrock, Klaus A.

    2015-01-01

    Intraarticular gadolinium-enhanced magnetic resonance arthrography (MRA) is commonly applied to characterize morphological disorders of the hip. However, the reproducibility of retrieving anatomic landmarks on MRA scans and their correlation with intraarticular pathologies is unknown. A precise mapping system for the exact localization of hip pathomorphologies with radial MRA sequences is lacking. Therefore, the purpose of the study was the establishment and validation of a reproducible mapping system for radial sequences of hip MRA. Sixty-nine consecutive intraarticular gadolinium-enhanced hip MRAs were evaluated. Radial sequencing consisted of 14 cuts orientated along the axis of the femoral neck. Three orthopedic surgeons read the radial sequences independently. Each MRI was read twice with a minimum interval of 7 days from the first reading. The intra- and inter-observer reliability of the mapping procedure was determined. A clockwise system for hip MRA was established. The teardrop figure served to determine the 6 o'clock position of the acetabulum; the center of the greater trochanter served to determine the 12 o'clock position of the femoral head-neck junction. The intra- and inter-observer ICCs to retrieve the correct 6/12 o'clock positions were 0.906-0.996 and 0.978-0.988, respectively. The established mapping system for radial sequences of hip joint MRA is reproducible and easy to perform. (orig.)

  13. Standard problem exercise to validate criticality codes for large arrays of packages of fissile materials

    International Nuclear Information System (INIS)

    Whitesides, G.E.; Stephens, M.E.

    1986-01-01

    A study has been conducted by an Office of Economic Cooperation and Development-Committee on the Safety of Nuclear Installations (OECD-CSNI) Working Group that examined computational methods used to compute k/sub eff/ for large greater than or equal to5 3 arrays of fissile material (in which each unit is a substantial fraction of a critical mass). Five fissile materials that might typically be transported were used in the study. The ''packages'' used for this exercise were simplified to allow studies unperturbed by the variety of structural materials which would exist in an actual package. The only material present other than the fissile material was a variation in the moderator (water) surrounding the fissile material. Consistent results were obtained from calculations using several computational methods. That is, when the bias demonstrated by each method for actual critical experiments was used to ''correct'' the results obtained for systems for which there were no experimental data, there was good agreement between the methods. Two major areas of concern were raised by this exercise. First, the lack of experimental data for arrays with size greater than 5 3 limits validation for large systems. Second, there is a distinct possibility that the comingling of two shipments of unlike units could result in a reduction of the safety margins. Additional experiments and calculations will be required to satisfactorily resolve the remaining questions regarding the safe transport of large arrays of fissile materials

  14. Sleep apnea detection by a cardiac resynchronization device integrated thoracic impedance sensor: A validation study against the gold standard polysomnography.

    Science.gov (United States)

    Barbieri, Fabian; Dichtl, Wolfgang; Heidbreder, Anna; Brandauer, Elisabeth; Stefani, Ambra; Adukauskaite, Agne; Senoner, Thomas; Schgör, Wilfried; Hintringer, Florian; Högl, Birgit

    2018-01-01

    Sleep disordered breathing is a common but often undiagnosed comorbidity in heart failure patients. Cardiac implantable electronic devices used for cardiac resynchronization therapy (CRT) may detect sleep apnea by use of a transthoracic impedance sensor. Validation of the AP scan® algorithm (Boston Scientific®) was performed by using the diagnostic gold standard polysomnography (PSG). Forty-one patients with impaired left ventricular ejection fraction, frequent right ventricular pacing due to atrioventricular block and heart failure symptoms despite optimal medical therapy underwent upgrading to biventricular pacing. Within one month after left ventricular lead implantation, sleep apnea was assessed by single-night PSG and AP scan® measurements. AP scan® measurements were valid in only 21 of 41 (51.2%) patients in the index night of the PSG. The PSG determined apnea-hypopnea index did not correlate statistically significant with the AP scan® measurements (r = 0.41, 95% confidence interval -0.05-0.72, p = 0.07). The degree of overestimation is displayed by using the Bland-Altman method: mean difference -12.4, standard deviation ± 15.8, 95% confidence interval -43.3-18.6. In heart failure patients receiving CRT upgrading, the AP scan® algorithm may need further improvement before it can be recommended for sleep apnea detection.

  15. MARS-KS code validation activity through the atlas domestic standard problem

    International Nuclear Information System (INIS)

    Choi, K. Y.; Kim, Y. S.; Kang, K. H.; Park, H. S.; Cho, S.

    2012-01-01

    The 2 nd Domestic Standard Problem (DSP-02) exercise using the ATLAS integral effect test data was executed to transfer the integral effect test data to domestic nuclear industries and to contribute to improving the safety analysis methodology for PWRs. A small break loss of coolant accident of a 6-inch break at the cold leg was determined as a target scenario by considering its technical importance and by incorporating interests from participants. Ten calculation results using MARS-KS code were collected, major prediction results were described qualitatively and code prediction accuracy was assessed quantitatively using the FFTBM. In addition, special code assessment activities were carried out to find out the area where the model improvement is required in the MARS-KS code. The lessons from this DSP-02 and recommendations to code developers are described in this paper. (authors)

  16. MISTRA facility for containment lumped parameter and CFD codes validation. Example of the International Standard Problem ISP47

    International Nuclear Information System (INIS)

    Tkatschenko, I.; Studer, E.; Paillere, H.

    2005-01-01

    During a severe accident in a Pressurized Water Reactor (PWR), the formation of a combustible gas mixture in the complex geometry of the reactor depends on the understanding of hydrogen production, the complex 3D thermal-hydraulics flow due to gas/steam injection, natural convection, heat transfer by condensation on walls and effect of mitigation devices. Numerical simulation of such flows may be performed either by Lumped Parameter (LP) or by Computational Fluid Dynamics (CFD) codes. Advantages and drawbacks of LP and CFD codes are well-known. LP codes are mainly developed for full size containment analysis but they need improvements, especially since they are not able to accurately predict the local gas mixing within the containment. CFD codes require a process of validation on well-instrumented experimental data before they can be used with a high degree of confidence. The MISTRA coupled effect test facility has been built at CEA to fulfil this validation objective: with numerous measurement points in the gaseous volume - temperature, gas concentration, velocity and turbulence - and with well controlled boundary conditions. As illustration of both experimental and simulation areas of this topic, a recent example in the use of MISTRA test data is presented for the case of the International Standard Problem ISP47. The proposed experimental work in the MISTRA facility provides essential data to fill the gaps in the modelling/validation of computational tools. (author)

  17. Validation of Proposed Metrics for Two-Body Abrasion Scratch Test Analysis Standards

    Science.gov (United States)

    Street, Kenneth W., Jr.; Kobrick, Ryan L.; Klaus, David M.

    2013-01-01

    Abrasion of mechanical components and fabrics by soil on Earth is typically minimized by the effects of atmosphere and water. Potentially abrasive particles lose sharp and pointed geometrical features through erosion. In environments where such erosion does not exist, such as the vacuum of the Moon, particles retain sharp geometries associated with fracturing of their parent particles by micrometeorite impacts. The relationship between hardness of the abrasive and that of the material being abraded is well understood, such that the abrasive ability of a material can be estimated as a function of the ratio of the hardness of the two interacting materials. Knowing the abrasive nature of an environment (abrasive)/construction material is crucial to designing durable equipment for use in such surroundings. The objective of this work was to evaluate a set of standardized metrics proposed for characterizing a surface that has been scratched from a two-body abrasion test. This is achieved by defining a new abrasion region termed Zone of Interaction (ZOI). The ZOI describes the full surface profile of all peaks and valleys, rather than just measuring a scratch width. The ZOI has been found to be at least twice the size of a standard width measurement; in some cases, considerably greater, indicating that at least half of the disturbed surface area would be neglected without this insight. The ZOI is used to calculate a more robust data set of volume measurements that can be used to computationally reconstruct a resultant profile for de tailed analysis. Documenting additional changes to various surface roughness par ameters also allows key material attributes of importance to ultimate design applications to be quantified, such as depth of penetration and final abraded surface roughness. Further - more, by investigating the use of custom scratch tips for specific needs, the usefulness of having an abrasion metric that can measure the displaced volume in this standardized

  18. Testing the validity of a Cd soil quality standard in representative Mediterranean agricultural soils under an accumulator crop

    International Nuclear Information System (INIS)

    Recatala, L.; Sanchez, J.; Arbelo, C.; Sacristan, D.

    2010-01-01

    The validity of a quality standard for cadmium (Cd) in representative agricultural Mediterranean soils under an accumulator crop (Lactuca sativa L.) is evaluated in this work considering both its effect on the crop growth (biomass production) and the metal accumulation in the edible part of the plant. Four soils with different properties relevant to regulate the behaviour of heavy metals were selected from the Valencian Region, a representative area of the European Mediterranean Region. For all soils, the effective concentration of added Cd causing 50% inhibition (EC 50 ) on the biomass production was much higher than the minimum legal concentration used to declare soils as contaminated by cadmium, i.e. 100 times the baseline value for Cd, in Spain (Spanish Royal Decree 9/2005). As expected, Cd toxicity in the crop was higher in the soils having less carbonate content. On the other hand, for all soils, from the second dose on, which represents 10-times the baseline value for Cd, the metal content in crops exceeded the maximum level established for leaf crops by the European legislation (Regulation EC no. 466/2001). Soil salinity and coarse textures make the accumulation of Cd in the edible part of the plant easier. Therefore, the legal baseline soil cadmium content established by the Spanish legislation seems not valid neither from the point of view of the effect on the crop growth nor from the point of view of the metal accumulation in the edible part of the plant. In order to realistically declare contaminated soils by heavy metals, soil quality standards should be proposed taking into account the soil properties. Further research in other agricultural areas of the region would improve the basis for proposing adequate soil quality standards for heavy metals as highlighted by the European Thematic Strategy for Soil Protection.

  19. Testing the validity of a Cd soil quality standard in representative Mediterranean agricultural soils under an accumulator crop

    Energy Technology Data Exchange (ETDEWEB)

    Recatala, L., E-mail: luis.recatala@uv.es [Departamento de Planificacion Territorial, Centro de Investigaciones sobre Desertificacion-CIDE (CSIC-Universitat de Valencia-Generalitat Valenciana), Cami de la Marjal S/N, 46470 Albal (Valencia) (Spain); Sanchez, J. [Departamento de Planificacion Territorial, Centro de Investigaciones sobre Desertificacion-CIDE (CSIC-Universitat de Valencia-Generalitat Valenciana), Cami de la Marjal S/N, 46470 Albal (Valencia) (Spain); Arbelo, C. [Departamento de Edafologia y Geologia, Facultad de Biologia, Universidad de La Laguna, 38206 La Laguna (Tenerife), Islas Canarias (Spain); Sacristan, D. [Departamento de Planificacion Territorial, Centro de Investigaciones sobre Desertificacion-CIDE (CSIC-Universitat de Valencia-Generalitat Valenciana), Cami de la Marjal S/N, 46470 Albal (Valencia) (Spain)

    2010-12-01

    The validity of a quality standard for cadmium (Cd) in representative agricultural Mediterranean soils under an accumulator crop (Lactuca sativa L.) is evaluated in this work considering both its effect on the crop growth (biomass production) and the metal accumulation in the edible part of the plant. Four soils with different properties relevant to regulate the behaviour of heavy metals were selected from the Valencian Region, a representative area of the European Mediterranean Region. For all soils, the effective concentration of added Cd causing 50% inhibition (EC{sub 50}) on the biomass production was much higher than the minimum legal concentration used to declare soils as contaminated by cadmium, i.e. 100 times the baseline value for Cd, in Spain (Spanish Royal Decree 9/2005). As expected, Cd toxicity in the crop was higher in the soils having less carbonate content. On the other hand, for all soils, from the second dose on, which represents 10-times the baseline value for Cd, the metal content in crops exceeded the maximum level established for leaf crops by the European legislation (Regulation EC no. 466/2001). Soil salinity and coarse textures make the accumulation of Cd in the edible part of the plant easier. Therefore, the legal baseline soil cadmium content established by the Spanish legislation seems not valid neither from the point of view of the effect on the crop growth nor from the point of view of the metal accumulation in the edible part of the plant. In order to realistically declare contaminated soils by heavy metals, soil quality standards should be proposed taking into account the soil properties. Further research in other agricultural areas of the region would improve the basis for proposing adequate soil quality standards for heavy metals as highlighted by the European Thematic Strategy for Soil Protection.

  20. Validation by theoretical approach to the experimental estimation of efficiency for gamma spectrometry of gas in 100 ml standard flask

    International Nuclear Information System (INIS)

    Mohan, V.; Chudalayandi, K.; Sundaram, M.; Krishnamony, S.

    1996-01-01

    Estimation of gaseous activity forms an important component of air monitoring at Madras Atomic Power Station (MAPS). The gases of importance are argon 41 an air activation product and fission product noble gas xenon 133. For estimating the concentration, the experimental method is used in which a grab sample is collected in a 100 ml volumetric standard flask. The activity of gas is then computed by gamma spectrometry using a predetermined efficiency estimated experimentally. An attempt is made using theoretical approach to validate the experimental method of efficiency estimation. Two analytical models named relative flux model and absolute activity model were developed independently of each other. Attention is focussed on the efficiencies for 41 Ar and 133 Xe. Results show that the present method of sampling and analysis using 100 ml volumetric flask is adequate and acceptable. (author). 5 refs., 2 tabs

  1. The reliability and validity of the standardized Mensendieck test in relation to disability in patients with chronic pain.

    Science.gov (United States)

    Keessen, Paul; Maaskant, Jolanda; Visser, Bart

    2018-08-01

    The standardized Mensendieck test (SMT) was developed to quantify posture, movement, gait, and respiration. In the hands of an experienced therapist, the SMT is proven to be a reliable tool. It is unclear whether posture, movement, gait, and respiration are related to the degree of functional disability in patients with chronic pain. The objective of this study was to assess the reliability and convergent validity of the SMT in a heterogeneous sample of 50 patients with chronic pain. Internal consistency was determined by Cronbach's α and interrater reliability by the intraclass correlation coefficient (ICC). Convergent validity was assessed by determining the Spearman rank correlation coefficient between the movement quality measured in the SMT and functional limitation measured on the disability rating index (DRI). The internal consistency was Cronbach's α 0.91. Substantial reliability was found for the items: movement (ICC = 0.68), gait (ICC = 0.69), sitting posture (ICC = 0.63), and respiration (ICC = 0.64). Insufficient reliability was found for standing posture (ICC = 0.23). A moderate correlation was found between average test score SMT and the DRI (r = -0.37) and respiration and DRI (r = -0.45). The SMT is a reasonably reliable tool to assess movement, gait, sitting posture, and respiration. None of the items in the domain standing posture has sufficient reliability. A thorough study of this domain should be considered. The results show little evidence for convergent validity. Several items of the SMT correlated moderately with functional limitation with the DRI. These items were global movement, hip flexion, pelvis rotation, and all respiration items.

  2. 110GHz ECH on DIII-D

    International Nuclear Information System (INIS)

    Cary, W.P.; Allen, J.C.; Callis, R.W.; Doane, J.L.; Harris, T.E.; Moetler, C.P.; Neren, A.; Prater, P.; Rensen, D.

    1992-01-01

    This paper reports on a new high power electron cyclotron heating (ECH) system which has been introduced on DIII-D. This system is designed to operate at 110 GHz with a total output power of 2 MW. The system consists of four Varian VGT-8011 gyrotrons (output power of 500 kW), and their associated support equipment. All components have been designed for up to a 10 second pulse duration. The 110 GHz system is intended to further progress in rf current drive experiments on DIII-D when used in conjunction with the existing 60 GHz ECH (1. 6 MW) , and the 30-60 MHz ICH (2MW) systems. H-mode physics, plasma stabilization experiments and transport studies are also to be conducted at 110 GHz

  3. Low conversion loss 94 GHz and 188 GHz doublers in InP DHBT technology

    DEFF Research Database (Denmark)

    Zhurbenko, Vitaliy; Johansen, Tom Keinicke; Squartecchia, Michele

    2017-01-01

    An Indium Phosphide (InP) Double Heterojunction Bipolar Transistor (DHBT) process has been utilized to design two doublers to cover the 94 GHz and 188 GHz bands. The 94 GHz doubler employs 4-finger DHBTs and provides conversion loss of 2 dB. A maximum output power of nearly 3 dBm is measured whil...... operate over a broad bandwidth. The total circuit area of each chip is 1.41 mm2....

  4. Extended wavelength anisotropy resolved multidimensional emission spectroscopy (ARMES) measurements: better filters, validation standards, and Rayleigh scatter removal methods

    Science.gov (United States)

    Casamayou-Boucau, Yannick; Ryder, Alan G.

    2017-09-01

    Anisotropy resolved multidimensional emission spectroscopy (ARMES) provides valuable insights into multi-fluorophore proteins (Groza et al 2015 Anal. Chim. Acta 886 133-42). Fluorescence anisotropy adds to the multidimensional fluorescence dataset information about the physical size of the fluorophores and/or the rigidity of the surrounding micro-environment. The first ARMES studies used standard thin film polarizers (TFP) that had negligible transmission between 250 and 290 nm, preventing accurate measurement of intrinsic protein fluorescence from tyrosine and tryptophan. Replacing TFP with pairs of broadband wire grid polarizers enabled standard fluorescence spectrometers to accurately measure anisotropies between 250 and 300 nm, which was validated with solutions of perylene in the UV and Erythrosin B and Phloxine B in the visible. In all cases, anisotropies were accurate to better than ±1% when compared to literature measurements made with Glan Thompson or TFP polarizers. Better dual wire grid polarizer UV transmittance and the use of excitation-emission matrix measurements for ARMES required complete Rayleigh scatter elimination. This was achieved by chemometric modelling rather than classical interpolation, which enabled the acquisition of pure anisotropy patterns over wider spectral ranges. In combination, these three improvements permit the accurate implementation of ARMES for studying intrinsic protein fluorescence.

  5. Recent operating experience with Varian 70 GHz and 140 GHz gyrotrons

    International Nuclear Information System (INIS)

    Felch, K.; Bier, R.; Fox, L.; Huey, H.; Ives, L.; Jory, H.; Lopez, N.; Shively, J.; Spang, S.

    1985-01-01

    The design features and initial test results of Varian 70 GHz and 140 GHz CW gyrotrons are presented. The first experimental 140 GHz tube has achieved an output power of 102 kW at 24% efficiency under pulsed conditions in the desired TE 031 0 cavity mode. Further tests aimed at achieving the design goal of 100 kW CW are currently underway. The 70 GHz tube has achieved an output power of 200 kW under pulsed conditions and possesses a wide dynamic range for output power variations. 6 refs., 8 figs

  6. Validation of simple and inexpensive algometry using sphygmomanometer cuff and neuromuscular junction monitor with standardized laboratory algometer

    Science.gov (United States)

    Durga, Padmaja; Wudaru, Sreedhar Reddy; Khambam, Sunil Kumar Reddy; Chandra, Shobha Jagadish; Ramachandran, Gopinath

    2016-01-01

    Background and Aims: The availability, ergonomics and economics prohibit the routine use of algometers in clinical practice and research by the anesthesiologists. A simple bedside technique of quantitative pain measurement would enable the routine use of algometry. We proposed to validate simple pain provocation using sphygmomanometer cuff and the electric stimulation of neuromuscular junction monitor (TOF-guard, Organon Teknika) to measure pain against a standardized laboratory pressure algometer. Material and Methods: Pain detection threshold (Pdt) and pain tolerance threshold (Ptt) were measured in forty healthy volunteers of both genders, using the above three techniques. All measurements were repeated three times. The co-efficient of inter-rater reliability (or consistency) between three independent measurements obtained from each of the techniques was determined by Cronbach's co-efficient alpha (α C). The correlation between the mean Pdt and Ptt values recorded by standardized algometer and the sphygmomanometer technique and nerve stimulator technique was performed using Pearson Correlation. An r >0.5 and a two-tailed significance of algometer and the tested techniques. Results: There was a good inter-rater reliability (α C > 0.7) for the three techniques. There was a good correlation with r >0.65 (P algometer and the two techniques being tested as alternatives for algometer to measure pain. Conclusion: The sphygmomanometer cuff technique and electrical stimulation with the peripheral nerve stimulator to measure pain threshold and tolerance provide a simple, efficient, repeatable measure of pain intensity and can be used as suitable alternatives to standard algometers. PMID:27006546

  7. A Universal Standard for the Validation of Blood Pressure Measuring Devices: Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Collaboration Statement.

    Science.gov (United States)

    Stergiou, George S; Alpert, Bruce; Mieke, Stephan; Asmar, Roland; Atkins, Neil; Eckert, Siegfried; Frick, Gerhard; Friedman, Bruce; Graßl, Thomas; Ichikawa, Tsutomu; Ioannidis, John P; Lacy, Peter; McManus, Richard; Murray, Alan; Myers, Martin; Palatini, Paolo; Parati, Gianfranco; Quinn, David; Sarkis, Josh; Shennan, Andrew; Usuda, Takashi; Wang, Jiguang; Wu, Colin O; O'Brien, Eoin

    2018-03-01

    In the past 30 years, several organizations, such as the US Association for the Advancement of Medical Instrumentation (AAMI), the British Hypertension Society, the European Society of Hypertension (ESH) Working Group on Blood Pressure (BP) Monitoring, and the International Organization for Standardization (ISO), have developed protocols for clinical validation of BP measuring devices. However, it is recognized that science, as well as patients, consumers, and manufacturers, would be best served if all BP measuring devices were assessed for accuracy according to an agreed single validation protocol that had global acceptance. Therefore, an international initiative was taken by the AAMI, ESH, and ISO experts who agreed to develop a universal standard for device validation. This statement presents the key aspects of a validation procedure, which were agreed by the AAMI, ESH, and ISO representatives as the basis for a single universal validation protocol. As soon as the AAMI/ESH/ISO standard is fully developed, this will be regarded as the single universal standard and will replace all other previous standards/protocols. © 2018 American Heart Association, Inc., and Wolters Kluwer Health, Inc.

  8. Structured surface reflector design for oblique incidence beam splitter at 610 GHz.

    Science.gov (United States)

    Defrance, F; Casaletti, M; Sarrazin, J; Wiedner, M C; Gibson, H; Gay, G; Lefèvre, R; Delorme, Y

    2016-09-05

    An iterative alternate projection-based algorithm is developed to design structured surface reflectors to operate as beam splitters at GHz and THz frequencies. To validate the method, a surface profile is determined to achieve a reflector at 610 GHz that generates four equal-intensity beams towards desired directions of ±12.6° with respect to the specular reflection axis. A prototype is fabricated and the beam splitter behavior is experimentally demonstrated. Measurements confirm a good agreement (within 1%) with computer simulations using Feko, validating the method. The beam splitter at 610 GHz has a measured efficiency of 78% under oblique incidence illumination that ensures a similar intensity between the four reflected beams (variation of about 1%).

  9. Is the standard compliance check protocol a valid measure of the accessibility of tobacco to underage smokers?

    Science.gov (United States)

    DiFranza, J.; Savageau, J.; Bouchard, J.

    2001-01-01

    OBJECTIVE—To determine if the standard compliance check protocol is a valid measure of the experience of underage smokers when purchasing tobacco in unfamiliar communities.
SETTING—160 tobacco outlets in eight Massachusetts communities where underage tobacco sales laws are vigorously enforced.
PROCEDURE—Completed purchase rates were compared between underage smokers who behaved normally and inexperienced non-smoking youths who were not allowed to lie or present proof of age (ID).
RESULTS—The "smoker protocol" increased the likelihood of a sale nearly sixfold over that for the non-smokers (odds ratio (OR) 5.7, 95% confidence interval (CI) 1.5 to 22). When the youths presented an ID with an underage birth date, the odds of a completed sale increased dramatically (OR 27, 95% CI 3.4 to 212). Clerks judged to be under 21 years of age were seven times more likely to make an illegal sale (OR 7.6, 95% CI 2.4 to 24.0).
CONCLUSIONS—Commonly used compliance check protocols are too artificial to reflect accurately the experience of underage smokers. The validity of compliance checks might be improved by having youths present ID, and by employing either tobacco users, or non-tobacco users who are sufficiently experienced to mimic the self confidence exhibited by tobacco users in this situation. Consideration should be given to prohibiting the sale of tobacco by individuals under 21 years of age.


Keywords: compliance check protocol; underage smokers PMID:11544386

  10. Validity of consumer-grade activity monitor to identify manual wheelchair propulsion in standardized activities of daily living.

    Science.gov (United States)

    Leving, Marika T; Horemans, Henricus L D; Vegter, Riemer J K; de Groot, Sonja; Bussmann, Johannes B J; van der Woude, Lucas H V

    2018-01-01

    Hypoactive lifestyle contributes to the development of secondary complications and lower quality of life in wheelchair users. There is a need for objective and user-friendly physical activity monitors for wheelchair-dependent individuals in order to increase physical activity through self-monitoring, goal setting, and feedback provision. To determine the validity of Activ8 Activity Monitors to 1) distinguish two classes of activities: independent wheelchair propulsion from other non-propulsive wheelchair-related activities 2) distinguish five wheelchair-related classes of activities differing by the movement intensity level: sitting in a wheelchair (hands may be moving but wheelchair remains stationary), maneuvering, and normal, high speed or assisted wheelchair propulsion. Sixteen able-bodied individuals performed sixteen various standardized 60s-activities of daily living. Each participant was equipped with a set of two Activ8 Professional Activity Monitors, one at the right forearm and one at the right wheel. Task classification by the Active8 Monitors was validated using video recordings. For the overall agreement, sensitivity and positive predictive value, outcomes above 90% are considered excellent, between 70 and 90% good, and below 70% unsatisfactory. Division in two classes resulted in overall agreement of 82.1%, sensitivity of 77.7% and positive predictive value of 78.2%. 84.5% of total duration of all tasks was classified identically by Activ8 and based on the video material. Division in five classes resulted in overall agreement of 56.6%, sensitivity of 52.8% and positive predictive value of 51.9%. 59.8% of total duration of all tasks was classified identically by Activ8 and based on the video material. Activ8 system proved to be suitable for distinguishing between active wheelchair propulsion and other non-propulsive wheelchair-related activities. The ability of the current system and algorithms to distinguish five various wheelchair-related activities

  11. The validity of parental reports on motor skills performance level in preschool children: a comparison with a standardized motor test.

    Science.gov (United States)

    Zysset, Annina E; Kakebeeke, Tanja H; Messerli-Bürgy, Nadine; Meyer, Andrea H; Stülb, Kerstin; Leeger-Aschmann, Claudia S; Schmutz, Einat A; Arhab, Amar; Ferrazzini, Valentina; Kriemler, Susi; Munsch, Simone; Puder, Jardena J; Jenni, Oskar G

    2018-05-01

    Motor skills are interrelated with essential domains of childhood such as cognitive and social development. Thus, the evaluation of motor skills and the identification of atypical or delayed motor development is crucial in pediatric practice (e.g., during well-child visits). Parental reports on motor skills may serve as possible indicators to decide whether further assessment of a child is necessary or not. We compared parental reports on fundamental motor skills performance level (e.g., hopping, throwing), based on questions frequently asked in pediatric practice, with a standardized motor test in 389 children (46.5% girls/53.5% boys, M age = 3.8 years, SD = 0.5, range 3.0-5.0 years) from the Swiss Preschoolers' Health Study (SPLASHY). Motor skills were examined using the Zurich Neuromotor Assessment 3-5 (ZNA3-5), and parents filled in an online questionnaire on fundamental motor skills performance level. The results showed that the answers from the parental report correlated only weakly with the objectively assessed motor skills (r = .225, p skills would be desirable, the parent's report used in this study was not a valid indicator for children's fundamental motor skills. Thus, we may recommend to objectively examine motor skills in clinical practice and not to exclusively rely on parental report. What is Known: • Early assessment of motor skills in preschool children is important because motor skills are essential for the engagement in social activities and the development of cognitive abilities. Atypical or delayed motor development can be an indicator for different developmental needs or disorders. • Pediatricians frequently ask parents about the motor competences of their child during well-child visits. What is New: • The parental report on fundamental motor skills performance level used in this study was not a reliable indicator for describing motor development in the preschool age. • Standardized examinations of motor skills are

  12. Antenne Design for 24 GHz and 60 GHz Emerging Microwave Applications

    NARCIS (Netherlands)

    Jansen, F.; Dolmans, W.M.C.

    2006-01-01

    In this project integrated antennas on a LAMP3 substrate for automotive radar systems at 24 GHz and wireless networks at 60 GHz have been designed. The most severe requirements on the antennas were the large bandwidth, which can not be met with conventional patch antennas. A tapered slot antenna and

  13. A 60 GHz Frequency Generator Based on a 20 GHz Oscillator and an Implicit Multiplier

    NARCIS (Netherlands)

    Zong, Z.; Babaie, M.; Staszewski, R.B.

    2016-01-01

    This paper proposes a mm-wave frequency generation technique that improves its phase noise (PN) performance and power efficiency. The main idea is that a fundamental 20 GHz signal and its sufficiently strong third harmonic at 60 GHz are generated simultaneously in a single oscillator. The desired 60

  14. Determination and validation of soil thresholds for cadmium based on food quality standard and health risk assessment.

    Science.gov (United States)

    Ding, Changfeng; Ma, Yibing; Li, Xiaogang; Zhang, Taolin; Wang, Xingxiang

    2018-04-01

    Cadmium (Cd) is an environmental toxicant with high rates of soil-plant transfer. It is essential to establish an accurate soil threshold for the implementation of soil management practices. This study takes root vegetable as an example to derive soil thresholds for Cd based on the food quality standard as well as health risk assessment using species sensitivity distribution (SSD). A soil type-specific bioconcentration factor (BCF, ratio of Cd concentration in plant to that in soil) generated from soil with a proper Cd concentration gradient was calculated and applied in the derivation of soil thresholds instead of a generic BCF value to minimize the uncertainty. The sensitivity variations of twelve root vegetable cultivars for accumulating soil Cd and the empirical soil-plant transfer model were investigated and developed in greenhouse experiments. After normalization, the hazardous concentrations from the fifth percentile of the distribution based on added Cd (HC5 add ) were calculated from the SSD curves fitted by Burr Type III distribution. The derived soil thresholds were presented as continuous or scenario criteria depending on the combination of soil pH and organic carbon content. The soil thresholds based on food quality standard were on average 0.7-fold of those based on health risk assessment, and were further validated to be reliable using independent data from field survey and published articles. The results suggested that deriving soil thresholds for Cd using SSD method is robust and also applicable to other crops as well as other trace elements that have the potential to cause health risk issues. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. 100 GHz Externally Modulated Laser for Optical Interconnects Applications

    DEFF Research Database (Denmark)

    Ozolins, Oskars; Pang, Xiaodan; Iglesias Olmedo, Miguel

    2017-01-01

    We report on a 116 Gb/s on-off keying (OOK), four pulse amplitude modulation (PAM) and 105-Gb/s 8-PAM optical transmitter using an InP-based integrated and packaged externally modulated laser for high-speed optical interconnects with up to 30 dB static extinction ratio and over 100-GHz 3-d......B bandwidth with 2 dB ripple. In addition, we study the tradeoff between power penalty and equalizer length to foresee transmission distances with standard single mode fiber....

  16. Contactless Investigations of Yeast Cell Cultivation in the 7 GHz and 240 GHz Ranges

    International Nuclear Information System (INIS)

    Wessel, J; Schmalz, K; Meliani, C; Gastrock, G; Cahill, B P

    2013-01-01

    Using a microfluidic system based on PTFE tubes, experimental results of contactless and label-free characterization techniques of yeast cell cultivation are presented. The PTFE tube has an inner diameter of 0.5 mm resulting in a sample volume of 2 μ1 for 1 cm sample length. Two approaches (at frequencies around 7 GHz and 240 GHz) are presented and compared in terms of sensitivity and applicability. These frequency bands are particularly interesting to gain information on the permittivity of yeast cells in Glucose solution. Measurements from 240 GHz to 300 GHz were conducted with a continuous wave spectrometer from Toptica. At 7 GHz band, measurements have been performed using a rat-race based characterizing system realized on a printed circuit board. The conducted experiments demonstrate that by selecting the phase as characterization parameter, the presented contactless and label-free techniques are suitable for cell cultivation monitoring in a PTFE pipe based microfluidic system.

  17. Submillimetric motion detection with a 94 GHz ground based synthetic aperture radar

    OpenAIRE

    Martinez Cervera, Arturo; Lort Cuenca, Marc; Aguasca Solé, Alberto; Broquetas Ibars, Antoni

    2015-01-01

    The paper presents the validation and experimental assessment of a 94 GHz (W-Band) CW-FM Radar that can be configured as a Ground Based SAR for high resolution imaging and interferometry. Several experimental campaigns have been carried out to assess the capability of the system to remotely observe submillimetric deformation and vibration in infrastructures. Peer Reviewed

  18. Standardization and validation of a cytometric bead assay to assess antibodies to multiple Plasmodium falciparum recombinant antigens

    Directory of Open Access Journals (Sweden)

    Ondigo Bartholomew N

    2012-12-01

    Full Text Available Abstract Background Multiplex cytometric bead assay (CBA have a number of advantages over ELISA for antibody testing, but little information is available on standardization and validation of antibody CBA to multiple Plasmodium falciparum antigens. The present study was set to determine optimal parameters for multiplex testing of antibodies to P. falciparum antigens, and to compare results of multiplex CBA to ELISA. Methods Antibodies to ten recombinant P. falciparum antigens were measured by CBA and ELISA in samples from 30 individuals from a malaria endemic area of Kenya and compared to known positive and negative control plasma samples. Optimal antigen amounts, monoplex vs multiplex testing, plasma dilution, optimal buffer, number of beads required were assessed for CBA testing, and results from CBA vs. ELISA testing were compared. Results Optimal amounts for CBA antibody testing differed according to antigen. Results for monoplex CBA testing correlated strongly with multiplex testing for all antigens (r = 0.88-0.99, P values from Conclusion With optimization, CBA may be the preferred method of testing for antibodies to P. falciparum antigens, as CBA can test for antibodies to multiple recombinant antigens from a single plasma sample and produces a greater range of values in positive samples and lower background readings for blank samples than ELISA.

  19. Standardized Ki67 Diagnostics Using Automated Scoring--Clinical Validation in the GeparTrio Breast Cancer Study.

    Science.gov (United States)

    Klauschen, Frederick; Wienert, Stephan; Schmitt, Wolfgang D; Loibl, Sibylle; Gerber, Bernd; Blohmer, Jens-Uwe; Huober, Jens; Rüdiger, Thomas; Erbstößer, Erhard; Mehta, Keyur; Lederer, Bianca; Dietel, Manfred; Denkert, Carsten; von Minckwitz, Gunter

    2015-08-15

    Scoring proliferation through Ki67 immunohistochemistry is an important component in predicting therapy response to chemotherapy in patients with breast cancer. However, recent studies have cast doubt on the reliability of "visual" Ki67 scoring in the multicenter setting, particularly in the lower, yet clinically important, proliferation range. Therefore, an accurate and standardized Ki67 scoring is pivotal both in routine diagnostics and larger multicenter studies. We validated a novel fully automated Ki67 scoring approach that relies on only minimal a priori knowledge on cell properties and requires no training data for calibration. We applied our approach to 1,082 breast cancer samples from the neoadjuvant GeparTrio trial and compared the performance of automated and manual Ki67 scoring. The three groups of autoKi67 as defined by low (≤ 15%), medium (15.1%-35%), and high (>35%) automated scores showed pCR rates of 5.8%, 16.9%, and 29.5%, respectively. AutoKi67 was significantly linked to prognosis with overall and progression-free survival P values P(OS) cancer that correlated with clinical endpoints and is deployable in routine diagnostics. It may thus help to solve recently reported reliability concerns in Ki67 diagnostics. ©2014 American Association for Cancer Research.

  20. Performance standard-based validation study for local lymph node assay: 5-bromo-2-deoxyuridine-flow cytometry method.

    Science.gov (United States)

    Ahn, Ilyoung; Kim, Tae-Sung; Jung, Eun-Sun; Yi, Jung-Sun; Jang, Won-Hee; Jung, Kyoung-Mi; Park, Miyoung; Jung, Mi-Sook; Jeon, Eun-Young; Yeo, Kyeong-Uk; Jo, Ji-Hoon; Park, Jung-Eun; Kim, Chang-Yul; Park, Yeong-Chul; Seong, Won-Keun; Lee, Ai-Young; Chun, Young Jin; Jeong, Tae Cheon; Jeung, Eui Bae; Lim, Kyung-Min; Bae, SeungJin; Sohn, Soojung; Heo, Yong

    2016-10-01

    Local lymph node assay: 5-bromo-2-deoxyuridine-flow cytometry method (LLNA: BrdU-FCM) is a modified non-radioisotopic technique with the additional advantages of accommodating multiple endpoints with the introduction of FCM, and refinement and reduction of animal use by using a sophisticated prescreening scheme. Reliability and accuracy of the LLNA: BrdU-FCM was determined according to OECD Test Guideline (TG) No. 429 (Skin Sensitization: Local Lymph Node Assay) performance standards (PS), with the participation of four laboratories. Transferability was demonstrated through successfully producing stimulation index (SI) values for 25% hexyl cinnamic aldehyde (HCA) consistently greater than 3, a predetermined threshold, by all participating laboratories. Within- and between-laboratory reproducibility was shown using HCA and 2,4-dinitrochlorobenzene, in which EC2.7 values (the estimated concentrations eliciting an SI of 2.7, the threshold for LLNA: BrdU-FCM) fell consistently within the acceptance ranges, 0.025-0.1% and 5-20%, respectively. Predictive capacity was tested using the final protocol version 1.3 for the 18 reference chemicals listed in OECD TG 429, of which results showed 84.6% sensitivity, 100% specificity, and 88.9% accuracy compared with the original LLNA. The data presented are considered to meet the performance criteria for the PS, and its predictive capacity was also sufficiently validated. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Steps to standardization and validation of hippocampal volumetry as a biomarker in clinical trials and diagnostic criteria for Alzheimer’s disease

    Science.gov (United States)

    Jack, Clifford R; Barkhof, Frederik; Bernstein, Matt A; Cantillon, Marc; Cole, Patricia E; DeCarli, Charles; Dubois, Bruno; Duchesne, Simon; Fox, Nick C; Frisoni, Giovanni B; Hampel, Harald; Hill, Derek LG; Johnson, Keith; Mangin, Jean-François; Scheltens, Philip; Schwarz, Adam J; Sperling, Reisa; Suhy, Joyce; Thompson, Paul M; Weiner, Michael; Foster, Norman L

    2012-01-01

    Background The promise of Alzheimer’s disease (AD) biomarkers has led to their incorporation in new diagnostic criteria and in therapeutic trials; however, significant barriers exist to widespread use. Chief among these is the lack of internationally accepted standards for quantitative metrics. Hippocampal volumetry is the most widely studied quantitative magnetic resonance imaging (MRI) measure in AD and thus represents the most rational target for an initial effort at standardization. Methods and Results The authors of this position paper propose a path toward this goal. The steps include: 1) Establish and empower an oversight board to manage and assess the effort, 2) Adopt the standardized definition of anatomic hippocampal boundaries on MRI arising from the EADC-ADNI hippocampal harmonization effort as a Reference Standard, 3) Establish a scientifically appropriate, publicly available Reference Standard Dataset based on manual delineation of the hippocampus in an appropriate sample of subjects (ADNI), and 4) Define minimum technical and prognostic performance metrics for validation of new measurement techniques using the Reference Standard Dataset as a benchmark. Conclusions Although manual delineation of the hippocampus is the best available reference standard, practical application of hippocampal volumetry will require automated methods. Our intent is to establish a mechanism for credentialing automated software applications to achieve internationally recognized accuracy and prognostic performance standards that lead to the systematic evaluation and then widespread acceptance and use of hippocampal volumetry. The standardization and assay validation process outlined for hippocampal volumetry is envisioned as a template that could be applied to other imaging biomarkers. PMID:21784356

  2. Validation of ammonia diffusive and active samplers in a controlled atmosphere test facility using traceable Primary Standard Gas Mixtures

    Science.gov (United States)

    Martin, Nicholas A.; Ferracci, Valerio; Cassidy, Nathan; Hook, Josh; Battersby, Ross M.; Tang, Yuk S.; Stevens, Amy C. M.; Jones, Matthew R.; Braban, Christine F.; Gates, Linda; Hangartner, Markus; Stoll, Jean-Marc; Sacco, Paolo; Pagani, Diego; Hoffnagle, John A.

    2017-04-01

    Intensive animal farming, the increased use of fertilizers, and certain industrial processes are believed to be responsible for the observed increases in the amount fraction of ammonia (NH3) found in Europe. NH3 contributes to eutrophication and acidification of land and freshwater, potentially leading to a loss of biodiversity and undesirable changes to the ecosystem. It also contributes to the formation of secondary particulate matter (PM) formation, which is associated with poor air quality and adverse health outcomes. Measurements of ambient ammonia are principally carried out with low-cost diffusive samplers or by active sampling with denuders, with each method delivering time-integrated values over the monitoring period. However, such techniques have not yet been extensively validated. The goal of this work was to provide improvements in the metrological traceability through the determination of NH3 diffusive sampling rates. Five different designs of commercial diffusive samplers (FSM Radiello radial sampler, Gradko diffusion tube, Gradko DIFRAM-400, Passam ammonia sampler, and CEH ALPHA sampler) were employed, together with a pumped denuder sampler (CEH DELTA denuder) for comparison. All devices were simultaneously exposed for either 28 days or 14 days (dependent on sampler type) in a controlled atmosphere test facility (CATFAC) containing traceable amount fractions of humidified ammonia using new stable ammonia Primary Standard Gas Mixtures developed by gravimetry at NPL, under a wide range of conditions that are relevant to ambient monitoring. Online continuous monitoring of the ammonia test atmospheres was carried out by extractive sampling, employing a calibrated cavity ring-down spectrometer, which had been modified to account for cross interference by water vapour. Each manufacturer extracted the captured ammonia on the exposed samplers in the form of ammonium (NH4+) using their own accredited traceable wet chemical techniques, and then reported data

  3. Histopathological Validation of the Surface-Intermediate-Base Margin Score for Standardized Reporting of Resection Technique during Nephron Sparing Surgery.

    Science.gov (United States)

    Minervini, Andrea; Campi, Riccardo; Kutikov, Alexander; Montagnani, Ilaria; Sessa, Francesco; Serni, Sergio; Raspollini, Maria Rosaria; Carini, Marco

    2015-10-01

    The surface-intermediate-base margin score is a novel standardized reporting system of resection techniques during nephron sparing surgery. We validated the surgeon assessed surface-intermediate-base score with microscopic histopathological assessment of partial nephrectomy specimens. Between June and August 2014 data were prospectively collected from 40 consecutive patients undergoing nephron sparing surgery. The surface-intermediate-base score was assigned to all cases. The score specific areas were color coded with tissue margin ink and sectioned for histological evaluation of healthy renal margin thickness. Maximum, minimum and mean thickness of healthy renal margin for each score specific area grade (surface [S] = 0, S = 1 ; intermediate [I] or base [B] = 0, I or B = 1, I or B = 2) was reported. The Mann-Whitney U and Kruskal-Wallis tests were used to compare the thickness of healthy renal margin in S = 0 vs 1 and I or B = 0 vs 1 vs 2 grades, respectively. Maximum, minimum and mean thickness of healthy renal margin was significantly different among score specific area grades S = 0 vs 1, and I or B = 0 vs 1, 0 vs 2 and 1 vs 2 (p <0.001). The main limitations of the study are the low number of the I or B = 1 and I or B = 2 samples and the assumption that each microscopic slide reflects the entire score specific area for histological analysis. The surface-intermediate-base scoring method can be readily harnessed in real-world clinical practice and accurately mirrors histopathological analysis for quantification and reporting of healthy renal margin thickness removed during tumor excision. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  4. Development of a Standardized Kalamazoo Communication Skills Assessment Tool for Radiologists: Validation, Multisource Reliability, and Lessons Learned.

    Science.gov (United States)

    Brown, Stephen D; Rider, Elizabeth A; Jamieson, Katherine; Meyer, Elaine C; Callahan, Michael J; DeBenedectis, Carolynn M; Bixby, Sarah D; Walters, Michele; Forman, Sara F; Varrin, Pamela H; Forbes, Peter; Roussin, Christopher J

    2017-08-01

    The purpose of this study was to develop and test a standardized communication skills assessment instrument for radiology. The Delphi method was used to validate the Kalamazoo Communication Skills Assessment instrument for radiology by revising and achieving consensus on the 43 items of the preexisting instrument among an interdisciplinary team of experts consisting of five radiologists and four nonradiologists (two men, seven women). Reviewers assessed the applicability of the instrument to evaluation of conversations between radiology trainees and trained actors portraying concerned parents in enactments about bad news, radiation risks, and diagnostic errors that were video recorded during a communication workshop. Interrater reliability was assessed by use of the revised instrument to rate a series of enactments between trainees and actors video recorded in a hospital-based simulator center. Eight raters evaluated each of seven different video-recorded interactions between physicians and parent-actors. The final instrument contained 43 items. After three review rounds, 42 of 43 (98%) items had an average rating of relevant or very relevant for bad news conversations. All items were rated as relevant or very relevant for conversations about error disclosure and radiation risk. Reliability and rater agreement measures were moderate. The intraclass correlation coefficient range was 0.07-0.58; mean, 0.30; SD, 0.13; and median, 0.30. The range of weighted kappa values was 0.03-0.47; mean, 0.23; SD, 0.12; and median, 0.22. Ratings varied significantly among conversations (χ 2 6 = 1186; p communication skills assessment instrument is highly relevant for radiology, having moderate interrater reliability. These findings have important implications for assessing the relational competencies of radiology trainees.

  5. Organizational Strategy Use in Children Aged 5–7: Standardization and Validity of the Rey Complex Figure Organizational Strategy Score (RCF-OSS)

    NARCIS (Netherlands)

    Martens, R.; Hurks, P.P.M.; Jolles, J.

    2014-01-01

    This study investigated psychometric properties (standardization and validity) of the Rey Complex Figure Organizational Strategy Score (RCF-OSS) in a sample of 217 healthy children aged 5-7 years. Our results showed that RCF-OSS performance changes significantly between 5 and 7 years of age. While

  6. VALIDATION OF MITRAL VALVE ANNULUS DIMENSIONS MEASURED BY 2D TRANS-THORACIC ECHOCARDIOGRAPHY WITH GOLD STANDARD DIRECT INTRA-OPERATIVE MEASUREMENT

    OpenAIRE

    Praveen; Yadav; Ankur; Saket; Kaushal

    2014-01-01

    CONTEXT: Precise estimation of Mitral valve annulus dimensions preoperatively through Echocardiography is of paramount importance in replacement/repair surgeries. However a frequent disagreement was experienced between anticipated size of prosthetic valve based on echocardiography and actual valve size. This fact encouraged the authors to validate the measurements through echocardiography with gold-standard direct intra operative measurement. AIM: To compare the mitral val...

  7. Integrated 60GHz RF Beamforming in CMOS

    NARCIS (Netherlands)

    Yu, Yikun; Baltus, P.G.M.; Roermund, van A.H.M.

    2011-01-01

    The 60GHz band is promising for applications such as high-speed short-range wireless personal area network (WPAN), real time video streaming at rates of several Gbps, automotive radar, and mm-Wave imaging, since it provides a large amount of bandwidth that can freely (i.e. without a license) be used

  8. A 24GHz Radar Receiver in CMOS

    NARCIS (Netherlands)

    Kwok, K.C.

    2015-01-01

    This thesis investigates the system design and circuit implementation of a 24GHz-band short-range radar receiver in CMOS technology. The propagation and penetration properties of EM wave offer the possibility of non-contact based remote sensing and through-the-wall imaging of distance stationary or

  9. Validation of Standardized Questionnaires Evaluating Symptoms of Depression in Rheumatoid Arthritis Patients: Approaches to Screening for a Frequent Yet Underrated Challenge.

    Science.gov (United States)

    Englbrecht, Matthias; Alten, Rieke; Aringer, Martin; Baerwald, Christoph G; Burkhardt, Harald; Eby, Nancy; Fliedner, Gerhard; Gauger, Bettina; Henkemeier, Ulf; Hofmann, Michael W; Kleinert, Stefan; Kneitz, Christian; Krueger, Klaus; Pohl, Christoph; Roske, Anne-Eve; Schett, Georg; Schmalzing, Marc; Tausche, Anne-Kathrin; Peter Tony, Hans; Wendler, Joerg

    2017-01-01

    To validate standard self-report questionnaires for depression screening in patients with rheumatoid arthritis (RA) and compare these measures to one another and to the Montgomery-Åsberg Depression Rating Scale (MADRS), a standardized structured interview. In 9 clinical centers across Germany, depressive symptomatology was assessed in 262 adult RA patients at baseline (T0) and at 12 ± 2 weeks followup (T1) using the World Health Organization 5-Item Well-Being Index (WHO-5), the Patient Health Questionnaire (PHQ-9), and the Beck Depression Inventory II (BDI-II). The construct validity of these depression questionnaires (using convergent and discriminant validity) was evaluated using Spearman's correlations at both time points. The test-retest reliability of the questionnaires was evaluated in RA patients who had not undergone a psychotherapeutic intervention or received antidepressants between T0 and T1. The sensitivity and the specificity of the questionnaires were calculated using the results of the MADRS, a structured interview, as the gold standard. According to Spearman's correlation coefficients, all questionnaires met convergent validity criteria (ρ > |0.50|), with the BDI-II performing best, while correlations with age and disease activity for all questionnaires met the criteria for discriminant validity (ρ questionnaire to meet the predefined retest reliability criterion (ρ ≥ 0.70) was the BDI-II (r s  = 0.77), which also achieved the best results for both sensitivity and specificity (>80%) when using the MADRS as the gold standard. The BDI-II best met the predefined criteria, and the PHQ-9 met most of the validity criteria, with lower sensitivity and specificity. © 2016, American College of Rheumatology.

  10. Magnetic films for GHz applications (abstract)

    International Nuclear Information System (INIS)

    Korenivski, V.; van Dover, R.B.

    1997-01-01

    Tremendous growth of the communications industry and the increasingly high demand for low-cost light-weight/small-size products drive technology to designs with a high degree of integration. In particular, planar inductors used in integrated circuits with significantly improved inductance per unit area characteristics are needed for further miniaturization of cellular phones operating at 0.95 and 1.9 GHz. Little has been done, however, to use magnetic films to improve the performance and/or reduce size of planar magnetic flux devices. The successful thin-film material would have a high ferromagnetic resonance (FMR) frequency (well above the operating frequency of the device), large permaeability, and low magnetic loss, and very importantly be technologically attractive, i.e., be process compatible with IC technology and have as few preparation steps as possible. Here, we report on fabrication of metallic ferromagnetic films of CoNbZr, CoNbZr/AlN mulitilayered laminates, and exchange-biased structures suitable for GHz applications. Lamination of CoNbZr with thin insulating layers of AlN is shown to significantly improve the microstructure and dc magnetic properties of the films having thicknesses >0.2 μm, as well as to be effective in suppressing eddy current losses at frequencies up to 1 endash 2 GHz. We use exchange biasing to increase the FMR frequency of soft CoNbZr. In-plane unidirectional anisotropy fields of ∼50 Oe are achieved, which result in FMR frequencies >2 GHz. Permeability values of ∼200 with quality factors of ∼10 at 1 GHz are demonstrated. The films are deposited at room temperature and require no postdeposition processing. Application of these films in planar inductors is discussed.copyright 1997 American Institute of Physics

  11. Validation of the RisingSun RS-651 Blood Pressure Monitor Based on Auscultation in Adults According to the ANSI/AAMI/ISO 81060-2:2013 Standard.

    Science.gov (United States)

    She, Jin; Guan, Xizhou; Liu, Yanyong; Xiang, Haiyan

    2016-12-01

    This study validated the RisingSun RS-651 blood pressure (BP) monitor based on auscultation in adults according to the American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization (ANSI/AAMI/ISO) 81060-2:2013 standard. The RS-651 device was evaluated in a study of 97 participants. The same arm simultaneous method, as defined in the ANSI/AAMI/ISO standard, was used. The mean differences±standard deviation for criterion 1 were 0.8±2.3 mm Hg for systolic BP (SBP) and -0.1±2.9 mm Hg for diastolic BP (DBP). Analysis for criterion 2 resulted in values of 0.8±1.5 mm Hg for SBP and -0.1±2.1 mm Hg for DBP. All of the data fulfilled the ANSI/AAMI/ISO 81060-2:2013 standard requirements to pass the validation. The RisingSun RS-651 device can be recommended for both clinical and self/home use in adults according to the ANSI/AAMI/ISO 81060-2:2013 standard. © 2016 The Authors. The Journal of Clinical Hypertension Published by Wiley Periodicals, Inc.

  12. 1 GHz GaAs Buck Converter for High Power Amplifier Modulation Applications

    NARCIS (Netherlands)

    Busking, E.B.; Hek, A.P. de; Vliet, F.E. van

    2012-01-01

    A fully integrated 1 GHz buck converter output stage, including on-chip inductor and DC output filtering has been realized, in a standard high-voltage breakdown GaAs MMIC technology. This is a significant step forward in designing highspeed power control of supply-modulated HPAs (high power

  13. 47 CFR 25.225 - Geographic Service Requirements for 17/24 GHz Broadcasting Satellite Service.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Geographic Service Requirements for 17/24 GHz Broadcasting Satellite Service. 25.225 Section 25.225 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES SATELLITE COMMUNICATIONS Technical Standards § 25.225 Geographic Service...

  14. Standardization and validation of a cytometric bead assay to assess antibodies to multiple Plasmodium falciparum recombinant antigens.

    Science.gov (United States)

    Ondigo, Bartholomew N; Park, Gregory S; Gose, Severin O; Ho, Benjamin M; Ochola, Lyticia A; Ayodo, George O; Ofulla, Ayub V; John, Chandy C

    2012-12-21

    Multiplex cytometric bead assay (CBA) have a number of advantages over ELISA for antibody testing, but little information is available on standardization and validation of antibody CBA to multiple Plasmodium falciparum antigens. The present study was set to determine optimal parameters for multiplex testing of antibodies to P. falciparum antigens, and to compare results of multiplex CBA to ELISA. Antibodies to ten recombinant P. falciparum antigens were measured by CBA and ELISA in samples from 30 individuals from a malaria endemic area of Kenya and compared to known positive and negative control plasma samples. Optimal antigen amounts, monoplex vs multiplex testing, plasma dilution, optimal buffer, number of beads required were assessed for CBA testing, and results from CBA vs. ELISA testing were compared. Optimal amounts for CBA antibody testing differed according to antigen. Results for monoplex CBA testing correlated strongly with multiplex testing for all antigens (r = 0.88-0.99, P values from <0.0001 - 0.004), and antibodies to variants of the same antigen were accurately distinguished within a multiplex reaction. Plasma dilutions of 1:100 or 1:200 were optimal for all antigens for CBA testing. Plasma diluted in a buffer containing 0.05% sodium azide, 0.5% polyvinylalcohol, and 0.8% polyvinylpyrrolidone had the lowest background activity. CBA median fluorescence intensity (MFI) values with 1,000 antigen-conjugated beads/well did not differ significantly from MFI with 5,000 beads/well. CBA and ELISA results correlated well for all antigens except apical membrane antigen-1 (AMA-1). CBA testing produced a greater range of values in samples from malaria endemic areas and less background reactivity for blank samples than ELISA. With optimization, CBA may be the preferred method of testing for antibodies to P. falciparum antigens, as CBA can test for antibodies to multiple recombinant antigens from a single plasma sample and produces a greater range of values in

  15. Unmanned Aircraft Systems Minimum Operations Performance Standards End-to-End Verification and Validation (E2-V2) Simulation

    Science.gov (United States)

    Ghatas, Rania W.; Jack, Devin P.; Tsakpinis, Dimitrios; Vincent, Michael J.; Sturdy, James L.; Munoz, Cesar A.; Hoffler, Keith D.; Dutle, Aaron M.; Myer, Robert R.; Dehaven, Anna M.; hide

    2017-01-01

    As Unmanned Aircraft Systems (UAS) make their way to mainstream aviation operations within the National Airspace System (NAS), research efforts are underway to develop a safe and effective environment for their integration into the NAS. Detect and Avoid (DAA) systems are required to account for the lack of "eyes in the sky" due to having no human on-board the aircraft. The current NAS relies on pilot's vigilance and judgement to remain Well Clear (CFR 14 91.113) of other aircraft. RTCA SC-228 has defined DAA Well Clear (DAAWC) to provide a quantified Well Clear volume to allow systems to be designed and measured against. Extended research efforts have been conducted to understand and quantify system requirements needed to support a UAS pilot's ability to remain well clear of other aircraft. The efforts have included developing and testing sensor, algorithm, alerting, and display requirements. More recently, sensor uncertainty and uncertainty mitigation strategies have been evaluated. This paper discusses results and lessons learned from an End-to-End Verification and Validation (E2-V2) simulation study of a DAA system representative of RTCA SC-228's proposed Phase I DAA Minimum Operational Performance Standards (MOPS). NASA Langley Research Center (LaRC) was called upon to develop a system that evaluates a specific set of encounters, in a variety of geometries, with end-to-end DAA functionality including the use of sensor and tracker models, a sensor uncertainty mitigation model, DAA algorithmic guidance in both vertical and horizontal maneuvering, and a pilot model which maneuvers the ownship aircraft to remain well clear from intruder aircraft, having received collective input from the previous modules of the system. LaRC developed a functioning batch simulation and added a sensor/tracker model from the Federal Aviation Administration (FAA) William J. Hughes Technical Center, an in-house developed sensor uncertainty mitigation strategy, and implemented a pilot

  16. Traveling-Wave Maser for 32 GHz

    Science.gov (United States)

    Shell, James; Clauss, Robert

    2009-01-01

    The figure depicts a traveling-wave ruby maser that has been designed (though not yet implemented in hardware) to serve as a low-noise amplifier for reception of weak radio signals in the frequency band of 31.8 to 32.3 GHz. The design offers significant improvements over previous designs of 32-GHz traveling-wave masers. In addition, relative to prior designs of 32-GHz amplifiers based on high-electron-mobility transistors, this design affords higher immunity to radio-frequency interference and lower equivalent input noise temperature. In addition to the basic frequency-band and low-noise requirements, the initial design problem included a requirement for capability of operation in a closed-cycle helium refrigerator at a temperature .4 K and a requirement that the design be mechanically simplified, relative to prior designs, in order to minimize the cost of fabrication and assembly. Previous attempts to build 32- GHz traveling-wave masers involved the use of metallic slow-wave structures comprising coupled transverse electromagnetic (TEM)-mode resonators that were subject to very tight tolerances and, hence, were expensive to fabricate and assemble. Impedance matching for coupling signals into and out of these earlier masers was very difficult. A key feature of the design is a slow-wave structure, the metallic portions of which would be mechanically relatively simple in that, unlike in prior slow-wave structures, there would be no internal metal steps, irises, or posts. The metallic portions of the slow-wave structure would consist only of two rectangular metal waveguide arms. The arms would contain sections filled with the active material (ruby) alternating with evanescent-wave sections. This structure would be transparent in both the signal-frequency band (the aforementioned range of 31.8 to 32.3 GHz) and the pump-frequency band (65.75 to 66.75 GHz), and would impose large slowing factors in both frequency bands. Resonant ferrite isolators would be placed in the

  17. Feasibility study and uncertainties in the validation of an existing safety-related control circuit with the ISO 13849-1:2006 design standard

    International Nuclear Information System (INIS)

    Jocelyn, Sabrina; Baudoin, James; Chinniah, Yuvin; Charpentier, Philippe

    2014-01-01

    In industry, machine users and people who modify or integrate equipment often have to evaluate the safety level of a safety-related control circuit that they have not necessarily designed. The modifications or integrations may involve work to make an existing machine that does not comply with normative or regulatory specifications safe. However, how can a circuit performing a safety function be validated a posteriori? Is the validation exercise feasible? What are the difficulties and limitations of such a procedure? The aim of this article is to answer these questions by presenting a validation study of a safety function of an existing machine. A plastic injection molding machine is used for this study, as well as standard ISO 13849-1:2006. Validation consists of performing an a posteriori (post-design) estimation of the performance level of the safety function. The procedure is studied for two contexts of use of the machine: in industry, and in laboratory. The calculations required by the ISO standard were done using Excel, followed by SIStema software. It is shown that, based on the context of use, the estimated performance level was different for the same safety-related circuit. The variability in the results is explained by the assumptions made by the person undertaking the validation without the involvement of the machine designer. - Highlights: • Validation of the performance level of a safety function is undertaken. • An injection molding machine and ISO 13849-1:2006 standard are used for the procedure. • The procedure is undertaken for two contexts of use of the machine. • In this study, the performance level depends on the context of use. • The assumptions made throughout the study partially explain this difference

  18. 400-GHz wireless transmission of 60-Gb/s nyquist-QPSK signals using UTC-PD and heterodyne mixer

    DEFF Research Database (Denmark)

    Yu, Xianbin; Asif, Rameez; Piels, Molly

    2016-01-01

    We experimentally demonstrate an optical network compatible high-speed optoelectronics THz wireless transmission system operating at 400-GHz band. In the experiment, optical Nyquist quadrature phase-shift keying signals in a 12.5-GHz ultradense wavelength-division multiplexing grid is converted...... to the THz wireless radiation by photomixing in an antenna integrated unitravelling photodiode. The photomixing is transparent to optical modulation formats. We also demonstrate in the experiment the scalability of our system by applying single to four channels, as well as mixed three channels. Wireless...... transmission of a capacity of 60 Gb/s for four channels (15 Gb/s per channel) at 400-GHz band is successfully achieved, which pushes the data rates enabled by optoelectronics approach beyond the envelope in the frequency range above 300 GHz. Besides those, this study also validates the potential of bridging...

  19. 105 GHz Notch Filter Design for Collective Thomson Scattering

    DEFF Research Database (Denmark)

    Furtula, Vedran; Michelsen, Poul; Leipold, Frank

    2011-01-01

    A millimeter-wave notch filter with 105-GHz center frequency, >20-GHz passband coverage, and 1-GHz rejection bandwidth has been constructed. The design is based on a fundamental rectangular waveguide with cylindrical cavities coupled by narrow iris gaps, i.e., small elongated holes of negligible...

  20. Superconducting ECR ion source: From 24-28 GHz SECRAL to 45 GHz fourth generation ECR

    Science.gov (United States)

    Zhao, H. W.; Sun, L. T.; Guo, J. W.; Zhang, W. H.; Lu, W.; Wu, W.; Wu, B. M.; Sabbi, G.; Juchno, M.; Hafalia, A.; Ravaioli, E.; Xie, D. Z.

    2018-05-01

    The development of superconducting ECR source with higher magnetic fields and higher microwave frequency is the most straight forward path to achieve higher beam intensity and higher charge state performance. SECRAL, a superconducting third generation ECR ion source, is designed for 24-28 GHz microwave frequency operation with an innovative magnet configuration of sextupole coils located outside the three solenoids. SECRAL at 24 GHz has already produced a number of record beam intensities, such as 40Ar12+ 1.4 emA, 129Xe26+ 1.1 emA, 129Xe30+ 0.36 emA, and 209Bi31+ 0.68 emA. SECRAL-II, an upgraded version of SECRAL, was built successfully in less than 3 years and has recently been commissioned at full power of a 28 GHz gyrotron and three-frequency heating (28 + 45 + 18 GHz). New record beam intensities for highly charged ion production have been achieved, such as 620 eμA 40Ar16+, 15 eμA 40Ar18+, 146 eμA 86Kr28+, 0.5 eμA 86Kr33+, 53 eμA 129Xe38+, and 17 eμA 129Xe42+. Recent beam test results at SECRAL and SECRAL II have demonstrated that the production of more intense highly charged heavy ion beams needs higher microwave power and higher frequency, as the scaling law predicted. A 45 GHz superconducting ECR ion source FECR (a first fourth generation ECR ion source) is being built at IMP. FECR will be the world's first Nb3Sn superconducting-magnet-based ECR ion source with 6.5 T axial mirror field, 3.5 T sextupole field on the plasma chamber inner wall, and 20 kW at a 45 GHz microwave coupling system. This paper will focus on SECRAL performance studies at 24-28 GHz and technical design of 45 GHz FECR, which demonstrates a technical path for highly charged ion beam production from 24 to 28 GHz SECRAL to 45 GHz FECR.

  1. Derivation and external validation of a case mix model for the standardized reporting of 30-day stroke mortality rates.

    Science.gov (United States)

    Bray, Benjamin D; Campbell, James; Cloud, Geoffrey C; Hoffman, Alex; James, Martin; Tyrrell, Pippa J; Wolfe, Charles D A; Rudd, Anthony G

    2014-11-01

    Case mix adjustment is required to allow valid comparison of outcomes across care providers. However, there is a lack of externally validated models suitable for use in unselected stroke admissions. We therefore aimed to develop and externally validate prediction models to enable comparison of 30-day post-stroke mortality outcomes using routine clinical data. Models were derived (n=9000 patients) and internally validated (n=18 169 patients) using data from the Sentinel Stroke National Audit Program, the national register of acute stroke in England and Wales. External validation (n=1470 patients) was performed in the South London Stroke Register, a population-based longitudinal study. Models were fitted using general estimating equations. Discrimination and calibration were assessed using receiver operating characteristic curve analysis and correlation plots. Two final models were derived. Model A included age (<60, 60-69, 70-79, 80-89, and ≥90 years), National Institutes of Health Stroke Severity Score (NIHSS) on admission, presence of atrial fibrillation on admission, and stroke type (ischemic versus primary intracerebral hemorrhage). Model B was similar but included only the consciousness component of the NIHSS in place of the full NIHSS. Both models showed excellent discrimination and calibration in internal and external validation. The c-statistics in external validation were 0.87 (95% confidence interval, 0.84-0.89) and 0.86 (95% confidence interval, 0.83-0.89) for models A and B, respectively. We have derived and externally validated 2 models to predict mortality in unselected patients with acute stroke using commonly collected clinical variables. In settings where the ability to record the full NIHSS on admission is limited, the level of consciousness component of the NIHSS provides a good approximation of the full NIHSS for mortality prediction. © 2014 American Heart Association, Inc.

  2. Velocity diagnostics of electron beams within a 140 GHz gyrotron

    International Nuclear Information System (INIS)

    Polevoy, J.T.

    1989-06-01

    Experimental measurements of the average axial velocity v parallel of the electron beam within the M.I.T. 140 GHz MW gyrotron have been performed. The method involves the simultaneous measurement of the radial electrostatic potential of the electron beam V p and the beam current I b . V p is measured through the use of a capacitive probe installed near or within the gyrotron cavity, while I b is measured with a previously installed Rogowski coil. Three capacitive probes have been designed and built, and two have operated within the gyrotron. The probe results are repeatable and consistent with theory. The measurements of v parallel and calculations of the corresponding transverse to longitudinal beam velocity ratio α = v perpendicular /v parallel at the cavity have been made at various gyrotron operation parameters. These measurements will provide insight into the causes of discrepancies between theoretical rf interaction efficiencies and experimental efficiencies obtained in experiments with the M.I.T. 140 GHz MW gyrotron. The expected values of v parallel and α are determined through the use of a computer code entitled EGUN. EGUN is used to model the cathode and anode regions of the gyrotron and it computes the trajectories and velocities of the electrons within the gyrotron. There is good correlation between the expected and measured values of α at low α, with the expected values from EGUN often falling within the standard errors of the measured values. 10 refs., 29 figs., 2 tabs

  3. THz photonic wireless links with 16-QAM modulation in the 375-450 GHz band

    DEFF Research Database (Denmark)

    Jia, Shi; Yu, Xianbin; Hu, Hao

    2016-01-01

    forward error correction (HD-FEC) threshold of 3.8e-3 with 7% overhead. In addition, we also successfully demonstrate hybrid photonic wireless transmission of 40 Gbit/s 16-QAM signal at carrier frequencies of 400 GHz and 425 GHz over 30 km standard single mode fiber (SSMF) between the optical baseband...... signal transmitter and the THz wireless transmitter with negligible induced power penalty.......We propose and experimentally demonstrate THz photonic wireless communication systems with 16-QAM modulation in the 375-450 GHz band. The overall throughput reaches as high as 80 Gbit/s by exploiting four THz channels with 5 Gbaud 16-QAM baseband modulation per channel. We create a coherent optical...

  4. 10 GHz ECRIS for Warsaw Cyclotron

    CERN Document Server

    Sudlitz, K

    1999-01-01

    Cusp type, 10 GHz ECRIS has been built and tested earlier. For obtaining intensive beams, more relevant for cyclotron, cusp geometry has been replaced by hexapole. Discharge chamber (stainless steel, 50 mm diameter, 250 mm long) is an extension of a coaxial line, feeding RF (9,6 GHz, up to 200 W) to the plasma. The NdFeB hexapole (0,52 T on the surface) has been used. The axial magnetic field is created by water cooled coils. The axial injection line dedicated to K160 isochronous heavy ion cyclotron has been constructed. The line consists of Glaser lenses, double focusing magnet, solenoid and mirror type inflector. The system provides sufficient transmission of the beam from ECR ion source to the firsts orbits of the cyclotron for m/q ranging from 7 to 2. After successful initial tests which were done in July 1997 the ECRIS serves as an external source for Warsaw Cyclotron.

  5. Working towards accreditation by the International Standards Organization 15189 Standard: how to validate an in-house developed method an example of lead determination in whole blood by electrothermal atomic absorption spectrometry.

    Science.gov (United States)

    Garcia Hejl, Carine; Ramirez, Jose Manuel; Vest, Philippe; Chianea, Denis; Renard, Christophe

    2014-09-01

    Laboratories working towards accreditation by the International Standards Organization (ISO) 15189 standard are required to demonstrate the validity of their analytical methods. The different guidelines set by various accreditation organizations make it difficult to provide objective evidence that an in-house method is fit for the intended purpose. Besides, the required performance characteristics tests and acceptance criteria are not always detailed. The laboratory must choose the most suitable validation protocol and set the acceptance criteria. Therefore, we propose a validation protocol to evaluate the performance of an in-house method. As an example, we validated the process for the detection and quantification of lead in whole blood by electrothermal absorption spectrometry. The fundamental parameters tested were, selectivity, calibration model, precision, accuracy (and uncertainty of measurement), contamination, stability of the sample, reference interval, and analytical interference. We have developed a protocol that has been applied successfully to quantify lead in whole blood by electrothermal atomic absorption spectrometry (ETAAS). In particular, our method is selective, linear, accurate, and precise, making it suitable for use in routine diagnostics.

  6. Characterisation of synthetic multi-element standards (SMELS) used for the validation of k(o)-NAA

    Czech Academy of Sciences Publication Activity Database

    Vermaercke, P.; Robouch, P.; Eguskiza, M.; De Corte, F.; Kennedy, G.; Smodiš, B.; Jaćimović, R.; Yonezawa, C.; Matsue, H.; Lin, X.; Blaauw, M.; Kučera, Jan

    2006-01-01

    Roč. 564, č. 2 (2006), s. 675-682 ISSN 0168-9002 Institutional research plan: CEZ:AV0Z10480505 Keywords : neutron activation analysis * ko-standardization * multi-element standard Subject RIV: CB - Analytical Chemistry, Separation

  7. Implementation of an Evidence-Based and Content Validated Standardized Ostomy Algorithm Tool in Home Care: A Quality Improvement Project.

    Science.gov (United States)

    Bare, Kimberly; Drain, Jerri; Timko-Progar, Monica; Stallings, Bobbie; Smith, Kimberly; Ward, Naomi; Wright, Sandra

    Many nurses have limited experience with ostomy management. We sought to provide a standardized approach to ostomy education and management to support nurses in early identification of stomal and peristomal complications, pouching problems, and provide standardized solutions for managing ostomy care in general while improving utilization of formulary products. This article describes development and testing of an ostomy algorithm tool.

  8. Polytomous diagnosis of ovarian tumors as benign, borderline, primary invasive or metastatic: development and validation of standard and kernel-based risk prediction models

    Directory of Open Access Journals (Sweden)

    Testa Antonia C

    2010-10-01

    Full Text Available Abstract Background Hitherto, risk prediction models for preoperative ultrasound-based diagnosis of ovarian tumors were dichotomous (benign versus malignant. We develop and validate polytomous models (models that predict more than two events to diagnose ovarian tumors as benign, borderline, primary invasive or metastatic invasive. The main focus is on how different types of models perform and compare. Methods A multi-center dataset containing 1066 women was used for model development and internal validation, whilst another multi-center dataset of 1938 women was used for temporal and external validation. Models were based on standard logistic regression and on penalized kernel-based algorithms (least squares support vector machines and kernel logistic regression. We used true polytomous models as well as combinations of dichotomous models based on the 'pairwise coupling' technique to produce polytomous risk estimates. Careful variable selection was performed, based largely on cross-validated c-index estimates. Model performance was assessed with the dichotomous c-index (i.e. the area under the ROC curve and a polytomous extension, and with calibration graphs. Results For all models, between 9 and 11 predictors were selected. Internal validation was successful with polytomous c-indexes between 0.64 and 0.69. For the best model dichotomous c-indexes were between 0.73 (primary invasive vs metastatic and 0.96 (borderline vs metastatic. On temporal and external validation, overall discrimination performance was good with polytomous c-indexes between 0.57 and 0.64. However, discrimination between primary and metastatic invasive tumors decreased to near random levels. Standard logistic regression performed well in comparison with advanced algorithms, and combining dichotomous models performed well in comparison with true polytomous models. The best model was a combination of dichotomous logistic regression models. This model is available online

  9. Training and validation of standardized patients for evaluation of general practitioners′ performance in management of obesity and overweight

    Directory of Open Access Journals (Sweden)

    Tahereh Changiz

    2014-01-01

    Conclusion: SP could be a powerful instrument for evaluating medical performance of general practitioners in the field of obesity/overweight management. Further research is needed to find the more aspects of training and validation of unannounced SPs in this field.

  10. Reliability and Validity of the Sensory Component of the International Standards for Neurological Classification of Spinal Cord Injury (ISNCSCI): A Systematic Review.

    Science.gov (United States)

    Hales, M; Biros, E; Reznik, J E

    2015-01-01

    Since 1982, the International Standards for Neurological Classification of Spinal Cord Injury (ISNCSCI) has been used to classify sensation of spinal cord injury (SCI) through pinprick and light touch scores. The absence of proprioception, pain, and temperature within this scale creates questions about its validity and accuracy. To assess whether the sensory component of the ISNCSCI represents a reliable and valid measure of classification of SCI. A systematic review of studies examining the reliability and validity of the sensory component of the ISNCSCI published between 1982 and February 2013 was conducted. The electronic databases MEDLINE via Ovid, CINAHL, PEDro, and Scopus were searched for relevant articles. A secondary search of reference lists was also completed. Chosen articles were assessed according to the Oxford Centre for Evidence-Based Medicine hierarchy of evidence and critically appraised using the McMasters Critical Review Form. A statistical analysis was conducted to investigate the variability of the results given by reliability studies. Twelve studies were identified: 9 reviewed reliability and 3 reviewed validity. All studies demonstrated low levels of evidence and moderate critical appraisal scores. The majority of the articles (~67%; 6/9) assessing the reliability suggested that training was positively associated with better posttest results. The results of the 3 studies that assessed the validity of the ISNCSCI scale were confounding. Due to the low to moderate quality of the current literature, the sensory component of the ISNCSCI requires further revision and investigation if it is to be a useful tool in clinical trials.

  11. Validation of five minimally obstructive methods to estimate physical activity energy expenditure in young adults in semi-standardized settings

    DEFF Research Database (Denmark)

    Schneller, Mikkel Bo; Pedersen, Mogens Theisen; Gupta, Nidhi

    2015-01-01

    We compared the accuracy of five objective methods, including two newly developed methods combining accelerometry and activity type recognition (Acti4), against indirect calorimetry, to estimate total energy expenditure (EE) of different activities in semi-standardized settings. Fourteen particip...

  12. Measurement Results of the Caltech Submillimeter Observatory 230 GHz and 460 GHz Balanced Receivers

    Science.gov (United States)

    Kooi, J. W.; Monje, R. R.; Force, B. L.; Rice, F.; Miller, D.; Phillips, T. G.

    2010-03-01

    The Caltech Submillimeter observatory (CSO) is located on top of Mauna Kea, Hawaii, at an altitude of 4.2km. The existing suite of heterodyne receivers covering the submillimeter band is rapidly aging, and in need of replacement. To this extend we have developed a family of balanced receivers covering the astrophysical important 180-720 GHz atmospheric windows. For the CSO, wide IF bandwidth receivers are implemented in a balanced receiver configuration with dual frequency observation capability. This arrangement was opted to be an optimal compromise between scientific merit and finite funding. In principle, the balanced receiver configuration has the advantage that common mode amplitude noise in the LO system is canceled, while at the same time utilizing all available LO power. Both of these features facilitate the use of commercially available synthesized LO system. In combination with a 4 GHz IF bandwidth, the described receiver layout allows for rapid high resolution spectral line surveys. Dual frequency observation is another important mode of operation offered by the new facility instrumentation. Two band observations are accomplished by separating the H and V polarizations of the incoming signal and routing them via folded optics to the appropriate polarization sensitive balanced mixer. Scientifically this observation mode facilitates pointing for the higher receiver band under mediocre weather conditions and a doubling of scientific throughput (2 x 4 GHz) under good weather conditions. Not only do these changes greatly enhance the spectroscopic capabilities of the CSO, they also enable the observatory to be integrated into the Harvard-Smithsonian Submillimeter Array (eSMA) as an additional baseline. The upgrade of the 345 GHz/650 GHz dual band balanced receivers is not far behind. All the needed hardware has been procured, and commissioning is expected the summer of 2010. The SIS junctions are capable of a 2-12 GHz bandwidth.

  13. From the validation of the standard model to the search for gravitational waves; Des tests du modele standard a la recherche d'ondes gravitationnelles

    Energy Technology Data Exchange (ETDEWEB)

    Tournefier, E

    2006-09-15

    The author reviews his activities concerning particle physics at Lep and LHC (Large Hadron Collider - CERN) and his latest works in the domain of gravitational waves. He has contributed first to the measurement of the parameters of the Z boson resonance and then to the extraction from experimental data of the standard model parameters like boson Higgs mass, top quark mass or the strong coupling constant. He has also worked on the development and testing of a LHC detector that will be useful to search for the Higgs boson via its decay in 2 photons. The Virgo experiment aims at detecting gravitational waves through interferometry, the author describes his contribution to the design of the detection system and gives a detailed review of the expected technical background noises. (A.C.)

  14. A pan-European ring trial to validate an International Standard for detection of Vibrio cholerae, Vibrio parahaemolyticus and Vibrio vulnificus in seafoods.

    Science.gov (United States)

    Hartnell, R E; Stockley, L; Keay, W; Rosec, J-P; Hervio-Heath, D; Van den Berg, H; Leoni, F; Ottaviani, D; Henigman, U; Denayer, S; Serbruyns, B; Georgsson, F; Krumova-Valcheva, G; Gyurova, E; Blanco, C; Copin, S; Strauch, E; Wieczorek, K; Lopatek, M; Britova, A; Hardouin, G; Lombard, B; In't Veld, P; Leclercq, A; Baker-Austin, C

    2018-02-10

    Globally, vibrios represent an important and well-established group of bacterial foodborne pathogens. The European Commission (EC) mandated the Comite de European Normalisation (CEN) to undertake work to provide validation data for 15 methods in microbiology to support EC legislation. As part of this mandated work programme, merging of ISO/TS 21872-1:2007, which specifies a horizontal method for the detection of V. parahaemolyticus and V. cholerae, and ISO/TS 21872-2:2007, a similar horizontal method for the detection of potentially pathogenic vibrios other than V. cholerae and V. parahaemolyticus was proposed. Both parts of ISO/TS 21872 utilized classical culture-based isolation techniques coupled with biochemical confirmation steps. The work also considered simplification of the biochemical confirmation steps. In addition, because of advances in molecular based methods for identification of human pathogenic Vibrio spp. classical and real-time PCR options were also included within the scope of the validation. These considerations formed the basis of a multi-laboratory validation study with the aim of improving the precision of this ISO technical specification and providing a single ISO standard method to enable detection of these important foodborne Vibrio spp.. To achieve this aim, an international validation study involving 13 laboratories from 9 countries in Europe was conducted in 2013. The results of this validation have enabled integration of the two existing technical specifications targeting the detection of the major foodborne Vibrio spp., simplification of the suite of recommended biochemical identification tests and the introduction of molecular procedures that provide both species level identification and discrimination of putatively pathogenic strains of V. parahaemolyticus by the determination of the presence of theromostable direct and direct related haemolysins. The method performance characteristics generated in this have been included in revised

  15. Validation of a smartphone auscultatory blood pressure kit Accutension XYZ-110 in adults according to the ANSI/AAMI/ISO 81060-2: 2013 standard.

    Science.gov (United States)

    Chu, Guang; Zhang, Zhi; Xu, Mengdan; Huang, Daini; Dai, Qiuyan

    2017-10-01

    The aim of this study was to validate the accuracy of the Accutension XYZ-110 blood pressure (BP) kit according to the American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization (ANSI/AAMI/ISO) 81060-2:2013 standard. Systolic blood pressure (SBP) and diastolic blood pressure (DBP) were measured simultaneously on the same arm in 85 Chinese adults (female : male=48 : 37) with a mean age of 43.2 years using the mercury sphygmomanometer (two observers) and the Accutension XYZ-110 device (one supervisor). The ANSI/AAMI/ISO 81060-2:2013 standard for the validation of BP-measuring devices in adults was followed precisely. A total of 255 comparison pairs were obtained for analysis. The mean device-observer difference in the 255 separate BP data pairs was 2.45±2.24 mmHg for SBP and 0.69±2.09 mmHg for DBP. The data were in accordance with the criterion 1 of the ANSI/AAMI/ISO 81060-2:2013 standard requirements (≤5±8 mmHg). In addition, the mean device-observer difference of the 85 participants was 2.45±1.47 mmHg for SBP and 0.69±1.36 mmHg for DBP. The device accuracy also fulfilled the criterion 2 with the SD of less than or equal to 6.47 for SBP and less than or equal to 6.90 mmHg for DBP. The Accutension XYZ-110 BP kit fulfilled the requirements of the ANSI/AAMI/ISO 81060-2:2013 standard, and hence could be recommended for both clinical and self/home BP measurement in adults.

  16. The London handicap scale: a re-evaluation of its validity using standard scoring and simple summation

    OpenAIRE

    Jenkinson, C.; Mant, J.; Carter, J.; Wade, D.; Winner, S.

    2000-01-01

    OBJECTIVE—To assess the validity of the London handicap scale (LHS) using a simple unweighted scoring system compared with traditional weighted scoring
METHODS—323 patients admitted to hospital with acute stroke were followed up by interview 6 months after their stroke as part of a trial looking at the impact of a family support organiser. Outcome measures included the six item LHS, the Dartmouth COOP charts, the Frenchay activities index, the Barthel index, and the hospital...

  17. Implementing the Science Assessment Standards: Developing and validating a set of laboratory assessment tasks in high school biology

    Science.gov (United States)

    Saha, Gouranga Chandra

    Very often a number of factors, especially time, space and money, deter many science educators from using inquiry-based, hands-on, laboratory practical tasks as alternative assessment instruments in science. A shortage of valid inquiry-based laboratory tasks for high school biology has been cited. Driven by this need, this study addressed the following three research questions: (1) How can laboratory-based performance tasks be designed and developed that are doable by students for whom they are designed/written? (2) Do student responses to the laboratory-based performance tasks validly represent at least some of the intended process skills that new biology learning goals want students to acquire? (3) Are the laboratory-based performance tasks psychometrically consistent as individual tasks and as a set? To answer these questions, three tasks were used from the six biology tasks initially designed and developed by an iterative process of trial testing. Analyses of data from 224 students showed that performance-based laboratory tasks that are doable by all students require careful and iterative process of development. Although the students demonstrated more skill in performing than planning and reasoning, their performances at the item level were very poor for some items. Possible reasons for the poor performances have been discussed and suggestions on how to remediate the deficiencies have been made. Empirical evidences for validity and reliability of the instrument have been presented both from the classical and the modern validity criteria point of view. Limitations of the study have been identified. Finally implications of the study and directions for further research have been discussed.

  18. 34 GHz, 45 MW pulsed magnicon

    International Nuclear Information System (INIS)

    Nezhevenko, Oleg A.; LaPointe, Michael A.; Yakovlev, Vyacheslav P.; Hirshfield, Jay L.; Serdobintsev, Gennady V.; Kuznetsov, Gennady I.; Persov, Boris Z.; Fix, Alexander

    2002-01-01

    A high efficiency, high power magnicon at 34.272 GHz has been designed and built as a microwave source to develop RF technology for a future multi-TeV electron-positron linear collider. The tube is designed to provide a peak output power of ∼45 MW in a 1 microsecond pulse, with a gain of 55 dB, using a 500 kV, 220 A, 1 mm-diameter electron beam. The status of the tube itself as well as the near-term experimental program is presented

  19. Electron gun simulation for 95 GHz gyrotron

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Udaybir; Kumar, Nitin; Sinha, A.K., E-mail: uday.ceeri@gmail.com, E-mail: aksinha@ceeri.ernet.in [Gyrotron Laboratory, Microwave Tube Area, Central Electronics Engineering Research Institute, Pilani (India); Purohit, L.P. [Department of Physics, Gurukul Kangri Vishwavidyalaya, Haridwar (India)

    2011-07-01

    A triode type Magnetron Injection Gun (MIG) for a 2 MW, 95 GHz Gyrotron has been designed by using commercially available code EGUN and another in-house developed code MIGANS. The operating mode of the gyrotron is TE{sub 24.8} and it is operated in the fundamental harmonic. The operating voltages of the modulating anode and the accelerating anode are 61 kV and 85 kV respectively. The parametric dependences of modulating anode voltage and cathode magnetic field on the beam quality have also been studied. (author)

  20. Electron gun simulation for 95 GHz gyrotron

    International Nuclear Information System (INIS)

    Singh, Udaybir; Kumar, Nitin; Sinha, A.K.; Purohit, L.P.

    2011-01-01

    A triode type Magnetron Injection Gun (MIG) for a 2 MW, 95 GHz Gyrotron has been designed by using commercially available code EGUN and another in-house developed code MIGANS. The operating mode of the gyrotron is TE 24.8 and it is operated in the fundamental harmonic. The operating voltages of the modulating anode and the accelerating anode are 61 kV and 85 kV respectively. The parametric dependences of modulating anode voltage and cathode magnetic field on the beam quality have also been studied. (author)

  1. Surveys of radio sources at 5 GHz

    International Nuclear Information System (INIS)

    Pauliny-Toth, I.I.K.

    1977-01-01

    A number of surveys have been carried out at a frequency of 5 GHz at the National Radio Astronomy Observatory (NRAO) and at the Max-Planck-Institut fuer Radioastronomy (MPIFR) with the aim of determining the number-flux density relation for the sources detected and also of obtaining their radio spectra and optical identifications. The surveys fall into two categories: first, the strong source (S) surveys which are intended in due course to cover the whole northern sky and to be complete above a flux density of about 0.6 Jy; second, surveys of limited areas of sky down to lower levels of the flux density. (Auth.)

  2. Assessment of the Performance of the Chilbolton 3-GHz Advanced Meteorological Radar for Cloud-Top-Height Retrieval.

    Science.gov (United States)

    Naud, C. M.; Muller, J.-P.; Slack, E. C.; Wrench, C. L.; Clothiaux, E. E.

    2005-06-01

    The Chilbolton 3-GHz Advanced Meteorological Radar (CAMRa), which is mounted on a fully steerable 25-m dish, can provide three-dimensional information on the presence of hydrometeors. The potential for this radar to make useful measurements of low-altitude liquid water cloud structure is investigated. To assess the cloud-height assignment capabilities of the 3-GHz radar, low-level cloud-top heights were retrieved from CAMRa measurements made between May and July 2003 and were compared with cloud-top heights retrieved from a vertically pointing 94-GHz radar that operates alongside CAMRa. The average difference between the 94- and 3-GHz radar-derived cloud-top heights is shown to be -0.1 ± 0.4 km. To assess the capability of 3-GHz radar scans to be used for satellite-derived cloud-top-height validation, multiangle imaging spectroradiometer (MISR) cloud-top heights were compared with both 94- and 3-GHz radar retrievals. The average difference between 94-GHz radar and MISR cloud-top heights is shown to be 0.1 ± 0.3 km, while the 3-GHz radar and MISR average cloud-top-height difference is shown to be -0.2 ± 0.6 km. In assessing the value of the CAMRa measurements, the problems associated with low-reflectivity values from stratiform liquid water clouds, ground clutter, and Bragg scattering resulting from turbulent mixing are all addressed. It is shown that, despite the difficulties, the potential exists for CAMRa measurements to contribute significantly to liquid water cloud-top-height retrievals, leading to the production of two-dimensional transects (i.e., maps) of cloud-top height.

  3. [Development of a standardized guide for optimizing drug adherence information to be dispensed during a pharmaceutical counseling with a multiple myeloma patient: Initial validation].

    Science.gov (United States)

    Favier-Archinard, Camille; Leguelinel-Blache, Géraldine; Dubois, Florent; Le Gall, Tanguy; Bourquard, Pascal; Passemard, Nadège; Tora, Sandrine; Rey, Aurélie; Rossi, Marie; Chevallier, Thierry; Cousin, Christelle; Favier, Mireille

    2018-05-01

    The safety of the community treatment with oral anticancer therapies is a strong theme of the cancer plan 2014-2019. The objective of this study was to develop a Pharmaceutical Counseling Guide to improve medication adherence in patients treated for multiple myeloma with oral anticancer therapies. A multidisciplinary professional working group selected a list of relevant medication adherence-related items that served as the framework for the design of the pharmaceutical counseling support materials in patient-accessible language. The readability, understanding and memorization of the information were validated in ten patients treated for myeloma. Twelve items were selected for treatment information (5 items), treatment planning (5 items), and adverse drug effects (2 items). A pharmacist guide, a patient guide, a medication schedule, and three self-questionnaires to evaluate medication knowledge and understanding of patients were developed. The patient test resulted in changes in these documents. This study carried out the initial validation of documents to standardize the pharmaceutical counseling for patients treated for myeloma so that it can be reproduced from one patient to another regardless of the pharmacist, by standardizing the information issued. This study needs to be completed by a final validation in myeloma patients, free from oral anticancer therapies. Copyright © 2018 Société Française du Cancer. Published by Elsevier Masson SAS. All rights reserved.

  4. Validity Evidence and Scoring Guidelines for Standardized Patient Encounters and Patient Notes From a Multisite Study of Clinical Performance Examinations in Seven Medical Schools.

    Science.gov (United States)

    Park, Yoon Soo; Hyderi, Abbas; Heine, Nancy; May, Win; Nevins, Andrew; Lee, Ming; Bordage, Georges; Yudkowsky, Rachel

    2017-11-01

    To examine validity evidence of local graduation competency examination scores from seven medical schools using shared cases and to provide rater training protocols and guidelines for scoring patient notes (PNs). Between May and August 2016, clinical cases were developed, shared, and administered across seven medical schools (990 students participated). Raters were calibrated using training protocols, and guidelines were developed collaboratively across sites to standardize scoring. Data included scores from standardized patient encounters for history taking, physical examination, and PNs. Descriptive statistics were used to examine scores from the different assessment components. Generalizability studies (G-studies) using variance components were conducted to estimate reliability for composite scores. Validity evidence was collected for response process (rater perception), internal structure (variance components, reliability), relations to other variables (interassessment correlations), and consequences (composite score). Student performance varied by case and task. In the PNs, justification of differential diagnosis was the most discriminating task. G-studies showed that schools accounted for less than 1% of total variance; however, for the PNs, there were differences in scores for varying cases and tasks across schools, indicating a school effect. Composite score reliability was maximized when the PN was weighted between 30% and 40%. Raters preferred using case-specific scoring guidelines with clear point-scoring systems. This multisite study presents validity evidence for PN scores based on scoring rubric and case-specific scoring guidelines that offer rigor and feedback for learners. Variability in PN scores across participating sites may signal different approaches to teaching clinical reasoning among medical schools.

  5. Content validation of a standardized algorithm for ostomy care.

    Science.gov (United States)

    Beitz, Janice; Gerlach, Mary; Ginsburg, Pat; Ho, Marianne; McCann, Eileen; Schafer, Vickie; Scott, Vera; Stallings, Bobbie; Turnbull, Gwen

    2010-10-01

    The number of ostomy care clinician experts is limited and the majority of ostomy care is provided by non-specialized clinicians or unskilled caregivers and family. The purpose of this study was to obtain content validation data for a new standardized algorithm for ostomy care developed by expert wound ostomy continence nurse (WOCN) clinicians. After face validity was established using overall review and suggestions from WOCN experts, 166 WOCNs self-identified as having expertise in ostomy care were surveyed online for 6 weeks in 2009. Using a cross-sectional, mixed methods study design and a 30-item instrument with a 4-point Likert-type scale, the participants were asked to quantify the degree of validity of the Ostomy Algorithm's decisions and components. Participants' open-ended comments also were thematically analyzed. Using a scale of 1 to 4, the mean score of the entire algorithm was 3.8 (4 = relevant/very relevant). The algorithm's content validity index (CVI) was 0.95 (out of 1.0). Individual component mean scores ranged from 3.59 to 3.91. Individual CVIs ranged from 0.90 to 0.98. Qualitative data analysis revealed themes of difficulty associated with algorithm formatting, especially orientation and use of the Studio Alterazioni Cutanee Stomali (Study on Peristomal Skin Lesions [SACS™ Instrument]) and the inability of algorithms to capture all individual patient attributes affecting ostomy care. Positive themes included content thoroughness and the helpful clinical photos. Suggestions were offered for algorithm improvement. Study results support the strong content validity of the algorithm and research to ascertain its construct validity and effect on care outcomes is warranted.

  6. Development and validation of a computerized algorithm for International Standards for Neurological Classification of Spinal Cord Injury (ISNCSCI)

    DEFF Research Database (Denmark)

    Walden, K; Bélanger, L M; Biering-Sørensen, F

    2016-01-01

    a standardized method to accurately derive the level and severity of SCI from the raw data of the ISNCSCI examination. The web interface assists in maximizing usability while minimizing the impact of human error in classifying SCI. SPONSORSHIP: This study is sponsored by the Rick Hansen Institute and supported...

  7. Development and validation of a portable gas phase standard generation and calibration system for volatile organic compounds

    Science.gov (United States)

    P. Veres; J. B. Gilman; J. M. Roberts; W. C. Kuster; C. Warneke; I. R. Burling; J. de Gouw

    2010-01-01

    We report on the development of an accurate, portable, dynamic calibration system for volatile organic compounds (VOCs). The Mobile Organic Carbon Calibration System (MOCCS) combines the production of gas-phase VOC standards using permeation or diffusion sources with quantitative total organic carbon (TOC) conversion on a palladium surface to CO2 in the presence of...

  8. Comparison of Stationarity Regions for Wireless Channels From 2 GHz to 30 GHz

    DEFF Research Database (Denmark)

    Yi, Tan; Wang, Chengxiang; Nielsen, Jesper Ødum

    2017-01-01

    Millimeter wave (mmWave) communication works in the frequencies above 6 gigahertz (GHz), with the system bandwidth up to 500 megahertz (MHz) or wider. In this case, the channel situations are dramatically different from the existing wireless channels in Third Generation/Fourth Generation (3G/4G...

  9. Instrumented Taylor anvil-on-rod impact tests for validating applicability of standard strength models to transient deformation states

    Science.gov (United States)

    Eakins, D. E.; Thadhani, N. N.

    2006-10-01

    Instrumented Taylor anvil-on-rod impact tests have been conducted on oxygen-free electronic copper to validate the accuracy of current strength models for predicting transient states during dynamic deformation events. The experiments coupled the use of high-speed digital photography to record the transient deformation states and laser interferometry to monitor the sample back (free surface) velocity as a measure of the elastic/plastic wave propagation through the sample length. Numerical continuum dynamics simulations of the impact and plastic wave propagation employing the Johnson-Cook [Proceedings of the Seventh International Symposium on Ballistics, 1983, The Netherlands (Am. Def. Prep. Assoc. (ADPA)), pp. 541-547], Zerilli-Armstrong [J. Appl. Phys. C1, 1816 (1987)], and Steinberg-Guinan [J. Appl. Phys. 51, 1498 (1980)] constitutive equations were used to generate transient deformation profiles and the free surface velocity traces. While these simulations showed good correlation with the measured free surface velocity traces and the final deformed sample shape, varying degrees of deviations were observed between the photographed and calculated specimen profiles at intermediate deformation states. The results illustrate the usefulness of the instrumented Taylor anvil-on-rod impact technique for validating constitutive equations that can describe the path-dependent deformation response and can therefore predict the transient and final deformation states.

  10. GHz-rate optical parametric amplifier in hydrogenated amorphous silicon

    International Nuclear Information System (INIS)

    Wang, Ke-Yao; Foster, Amy C

    2015-01-01

    We demonstrate optical parametric amplification operating at GHz-rates at telecommunications wavelengths using a hydrogenated amorphous silicon waveguide through the nonlinear optical process of four-wave mixing. We investigate how the parametric amplification scales with repetition rate. The ability to achieve amplification at GHz-repetition rates shows hydrogenated amorphous silicon’s potential for telecommunication applications and a GHz-rate optical parametric oscillator. (paper)

  11. Development and validation of new spectrophotometric ratio H-point standard addition method and application to gastrointestinal acting drugs mixtures

    Science.gov (United States)

    Yehia, Ali M.

    2013-05-01

    New, simple, specific, accurate and precise spectrophotometric technique utilizing ratio spectra is developed for simultaneous determination of two different binary mixtures. The developed ratio H-point standard addition method (RHPSAM) was managed successfully to resolve the spectral overlap in itopride hydrochloride (ITO) and pantoprazole sodium (PAN) binary mixture, as well as, mosapride citrate (MOS) and PAN binary mixture. The theoretical background and advantages of the newly proposed method are presented. The calibration curves are linear over the concentration range of 5-60 μg/mL, 5-40 μg/mL and 4-24 μg/mL for ITO, MOS and PAN, respectively. Specificity of the method was investigated and relative standard deviations were less than 1.5. The accuracy, precision and repeatability were also investigated for the proposed method according to ICH guidelines.

  12. Comparison and validation of methods to quantify Cry1Ab toxin from Bacillus thuringiensis for standardization of insect bioassays.

    Science.gov (United States)

    Crespo, André L B; Spencer, Terence A; Nekl, Emily; Pusztai-Carey, Marianne; Moar, William J; Siegfried, Blair D

    2008-01-01

    Standardization of toxin preparations derived from Bacillus thuringiensis (Berliner) used in laboratory bioassays is critical for accurately assessing possible changes in the susceptibility of field populations of target pests. Different methods were evaluated to quantify Cry1Ab, the toxin expressed by 80% of the commercially available transgenic maize that targets the European corn borer, Ostrinia nubilalis (Hübner). We compared three methods of quantification on three different toxin preparations from independent sources: enzyme-linked immunosorbent assay (ELISA), sodium dodecyl sulfate-polyacrylamide gel electrophoresis and densitometry (SDS-PAGE/densitometry), and the Bradford assay for total protein. The results were compared to those obtained by immunoblot analysis and with the results of toxin bioassays against susceptible laboratory colonies of O. nubilalis. The Bradford method resulted in statistically higher estimates than either ELISA or SDS-PAGE/densitometry but also provided the lowest coefficients of variation (CVs) for estimates of the Cry1Ab concentration (from 2.4 to 5.4%). The CV of estimates obtained by ELISA ranged from 12.8 to 26.5%, whereas the CV of estimates obtained by SDS-PAGE/densitometry ranged from 0.2 to 15.4%. We standardized toxin concentration by using SDS-PAGE/densitometry, which is the only method specific for the 65-kDa Cry1Ab protein and is not confounded by impurities detected by ELISA and Bradford assay for total protein. Bioassays with standardized Cry1Ab preparations based on SDS-PAGE/densitometry showed no significant differences in LC(50) values, although there were significant differences in growth inhibition for two of the three Cry1Ab preparations. However, the variation in larval weight caused by toxin source was only 4% of the total variation, and we conclude that standardization of Cry1Ab production and quantification by SDS-PAGE/densitometry may improve data consistency in monitoring efforts to identify changes in

  13. Scan-To Output Validation: Towards a Standardized Geometric Quality Assessment of Building Information Models Based on Point Clouds

    Science.gov (United States)

    Bonduel, M.; Bassier, M.; Vergauwen, M.; Pauwels, P.; Klein, R.

    2017-11-01

    The use of Building Information Modeling (BIM) for existing buildings based on point clouds is increasing. Standardized geometric quality assessment of the BIMs is needed to make them more reliable and thus reusable for future users. First, available literature on the subject is studied. Next, an initial proposal for a standardized geometric quality assessment is presented. Finally, this method is tested and evaluated with a case study. The number of specifications on BIM relating to existing buildings is limited. The Levels of Accuracy (LOA) specification of the USIBD provides definitions and suggestions regarding geometric model accuracy, but lacks a standardized assessment method. A deviation analysis is found to be dependent on (1) the used mathematical model, (2) the density of the point clouds and (3) the order of comparison. Results of the analysis can be graphical and numerical. An analysis on macro (building) and micro (BIM object) scale is necessary. On macro scale, the complete model is compared to the original point cloud and vice versa to get an overview of the general model quality. The graphical results show occluded zones and non-modeled objects respectively. Colored point clouds are derived from this analysis and integrated in the BIM. On micro scale, the relevant surface parts are extracted per BIM object and compared to the complete point cloud. Occluded zones are extracted based on a maximum deviation. What remains is classified according to the LOA specification. The numerical results are integrated in the BIM with the use of object parameters.

  14. Velocity diagnostics of electron beams within a 140 GHz gyrotron

    Science.gov (United States)

    Polevoy, Jeffrey Todd

    1989-06-01

    Experimental measurements of the average axial velocity v(sub parallel) of the electron beam within the M.I.T. 140 GHz MW gyrotron have been performed. The method involves the simultaneous measurement of the radial electrostatic potential of the electron beam V(sub p) and the beam current I(sub b). The V(sub p) is measured through the use of a capacitive probe installed near or within the gyrotron cavity, while I(sub b) is measured with a previously installed Rogowski coil. Three capacitive probes have been designed and built, and two have operated within the gyrotron. The probe results are repeatable and consistent with theory. The measurements of v(sub parallel) and calculations of the corresponding transverse to longitudinal beam velocity ratio (alpha) = v(sub perpendicular)/v(sub parallel) at the cavity have been made at various gyrotron operation parameters. These measurements will provide insight into the causes of discrepancies between theoretical RF interaction efficiencies and experimental efficiencies obtained in experiments with the M.I.T. 140 GHz MW gyrotron. The expected values of v(sub parallel) and (alpha) are determined through the use of a computer code (EGUN) which is used to model the cathode and anode regions of the gyrotron. It also computes the trajectories and velocities of the electrons within the gyrotron. There is good correlation between the expected and measured values of (alpha) at low (alpha), with the expected values from EGUN often falling within the standard errors of the measured values.

  15. Reliability and Validity of the Sensory Component of the International Standards for Neurological Classification of Spinal Cord Injury (ISNCSCI): A Systematic Review

    Science.gov (United States)

    Hales, M.; Biros, E.

    2015-01-01

    Background: Since 1982, the International Standards for Neurological Classification of Spinal Cord Injury (ISNCSCI) has been used to classify sensation of spinal cord injury (SCI) through pinprick and light touch scores. The absence of proprioception, pain, and temperature within this scale creates questions about its validity and accuracy. Objectives: To assess whether the sensory component of the ISNCSCI represents a reliable and valid measure of classification of SCI. Methods: A systematic review of studies examining the reliability and validity of the sensory component of the ISNCSCI published between 1982 and February 2013 was conducted. The electronic databases MEDLINE via Ovid, CINAHL, PEDro, and Scopus were searched for relevant articles. A secondary search of reference lists was also completed. Chosen articles were assessed according to the Oxford Centre for Evidence-Based Medicine hierarchy of evidence and critically appraised using the McMasters Critical Review Form. A statistical analysis was conducted to investigate the variability of the results given by reliability studies. Results: Twelve studies were identified: 9 reviewed reliability and 3 reviewed validity. All studies demonstrated low levels of evidence and moderate critical appraisal scores. The majority of the articles (~67%; 6/9) assessing the reliability suggested that training was positively associated with better posttest results. The results of the 3 studies that assessed the validity of the ISNCSCI scale were confounding. Conclusions: Due to the low to moderate quality of the current literature, the sensory component of the ISNCSCI requires further revision and investigation if it is to be a useful tool in clinical trials. PMID:26363591

  16. A standard analysis method (SAM) for the automated analysis of polychlorinated biphenyls (PCBs) in soils using the chemical analysis automation (CAA) paradigm: validation and performance

    International Nuclear Information System (INIS)

    Rzeszutko, C.; Johnson, C.R.; Monagle, M.; Klatt, L.N.

    1997-10-01

    The Chemical Analysis Automation (CAA) program is developing a standardized modular automation strategy for chemical analysis. In this automation concept, analytical chemistry is performed with modular building blocks that correspond to individual elements of the steps in the analytical process. With a standardized set of behaviors and interactions, these blocks can be assembled in a 'plug and play' manner into a complete analysis system. These building blocks, which are referred to as Standard Laboratory Modules (SLM), interface to a host control system that orchestrates the entire analytical process, from sample preparation through data interpretation. The integrated system is called a Standard Analysis Method (SAME). A SAME for the automated determination of Polychlorinated Biphenyls (PCB) in soils, assembled in a mobile laboratory, is undergoing extensive testing and validation. The SAME consists of the following SLMs: a four channel Soxhlet extractor, a High Volume Concentrator, column clean up, a gas chromatograph, a PCB data interpretation module, a robot, and a human- computer interface. The SAME is configured to meet the requirements specified in U.S. Environmental Protection Agency's (EPA) SW-846 Methods 3541/3620A/8082 for the analysis of pcbs in soils. The PCB SAME will be described along with the developmental test plan. Performance data obtained during developmental testing will also be discussed

  17. Circular waveguide mode converters at 140 GHz

    International Nuclear Information System (INIS)

    Trulsen, J.; Woskoboinikow, P.; Temkin, R.J.

    1986-01-01

    A unified derivation of the coupled mode equations for circular waveguide is presented. Also, approximate design criteria for TE/sub 0n/ to TE/sub 0n'/ axisymmetric, TE 01 to TE 11 wriggle, and TE 01 to TM 11 bend converters are reviewed. Numerically solving the coupled mode equations, an optimized set of mode converters has been designed for conversion of a 2 millimeter wave TE 03 mode into TE 11 . This set consists of axisymmetric TE 03 to TE 02 and TE 02 to TE 01 converters followed by a wriggle TE 01 to TE 11 converter. This mode converter set was fabricated and tested using a 3 kW, 137 GHz gyrotron. A TE 11 mode purity of better than 97% was achieved. The TE 01 to TE 11 wriggle converter was experimentally optimized for a measured conversion efficiency of better than 99% not including ohmic losses

  18. 30 GHz High Power Production for CLIC

    CERN Document Server

    Syratchev, I V

    2006-01-01

    The CLIC Power Extraction and Transfer Structure (PETS) is a passive microwave device in which bunches of the drive beam interact with the impedance of the periodically loaded waveguide and excite preferentially the synchronous TM01 mode at 30 GHz. The RF power produced (several hundred MW) is collected at the downstream end of the structure by means of the Power Extractor and conveyed to the main linac structure. The PETS geometry is a result of multiple compromises between beam stability along a single decelerator sector (600 m) and the active length of the structure to match the main linac RF power needs and layout. Surface electric and magnetic fields, power extraction method, HOM damping, ON/OFF capability and fabrication technology were all evaluated to provide a reliable design.

  19. Quantum limited quasiparticle mixers at 100 GHz

    International Nuclear Information System (INIS)

    Mears, C.A; Hu, Qing; Richards, P.L.; Worsham, A.H.; Prober, D.E.; Raeisaenen, A.V.

    1990-09-01

    We have made accurate measurements of the noise and gain of superconducting-insulating-superconducting (SIS) mixers employing small area (1μm 2 ) Ta/Ta 2 O 5 /Pb 0.9 Bi 0.1 tunnel junctions. We have measured an added mixer noise of 0.61 +/- 0.31 quanta at 95.0 GHz, which is within 25 percent of the quantum limit of 0.5 quanta. We have carried out a detailed comparison between theoretical predictions of the quantum theory of mixing and experimentally measured noise and gain. We used the shapes of I-V curves pumped at the upper and lower sideband frequencies to deduce values of the embedding admittances at these frequencies. Using these admittances, the mixer noise and gain predicted by quantum theory are in excellent agreement with experiment. 21 refs., 9 figs

  20. Direct satellite TV - The 12-GHz challenge

    Science.gov (United States)

    Fawcette, J.

    1982-02-01

    Manufacturers in Japan and Europe are developing the hardware necessary for commercially feasible direct broadcast satellite TV, including high-frequency circuits and mini-dishes for spacecasting. US companies are lagging behind due to formidable regulatory and legal difficulties. The article focuses on efforts to develop simple, inexpensive receivers which will be able to convert 12-GHz satellite transmissions into high-quality TV images. Three basic receiver designs are being developed: the mixer-downcaster, microwave integrated circuits using FET-preamplifier front ends with transistors connected by bond-wires, and monolithic gallium arsenide integrated circuits. Several companies are on the verge of introducing commercialized receivers utilizing these different basic designs.

  1. Effects of Variable Spot Size on Human Exposure to 95 GHz Millimeter Wave Energy

    Science.gov (United States)

    2017-05-11

    Laboratory. Ross, J. A., Allen, S. J., Beason, C. W., & Johnson, L. R. (2008). Power density measurement of 94-GHz radiofrequency radiation using carbon...effectiveness) at the smallest spot size. 15. SUBJECT TERMS Avoidance, behavior, millimeter waves, nonlethal weapons, radiofrequency 16...System power density measurements (mean ± standard deviation) for the three different power density settings (low, middle, high) used in Experiment 1B

  2. Standard model of WWER-440 fuel rod for Transuranus and its application for RELAP5 hot channel validation

    International Nuclear Information System (INIS)

    Hatala, B.; Cvan, M.

    2001-01-01

    Within the PECO European Commission project of 'Extension of the validation matrix of the TRANSURANUS code' is developed a generic model of WWER-440 fuel rod. The model is intended to be applied for both realistic and licensing, conservative analysis. For such an application the TRANSURANUS code would be complementary tool to generally used system codes, e.g. RELAP5, providing realistic, more detailed insight into processes and safety criteria, relevant to the fuel rod. The paper presents general description of the model for TRANSURANUS code, brief discussion of approaches used in TRANSURANUS and RELAP5 code safety analysis, accompanied with information about RELAP5 model (whole scope unit model, used for licensing analysis). The existing model for RELAP5 code for WWER-440/V-213 Bohunice V2 unit is checked and modified in hot channel part to allow transparent comparison with the TRANSURANUS code. The results from comparison calculations of the both codes are presented for fresh fuel and quasi steady state scenario and are in good agreement, almost identical. These results might be used as a basis for transient analysis

  3. Validation of a standard forensic anthropology examination protocol by measurement of applicability and reliability on exhumed and archive samples of known biological attribution.

    Science.gov (United States)

    Francisco, Raffaela Arrabaça; Evison, Martin Paul; Costa Junior, Moacyr Lobo da; Silveira, Teresa Cristina Pantozzi; Secchieri, José Marcelo; Guimarães, Marco Aurelio

    2017-10-01

    Forensic anthropology makes an important contribution to human identification and assessment of the causes and mechanisms of death and body disposal in criminal and civil investigations, including those related to atrocity, disaster and trafficking victim identification. The methods used are comparative, relying on assignment of questioned material to categories observed in standard reference material of known attribution. Reference collections typically originate in Europe and North America, and are not necessarily representative of contemporary global populations. Methods based on them must be validated when applied to novel populations. This study describes the validation of a standardized forensic anthropology examination protocol by application to two contemporary Brazilian skeletal samples of known attribution. One sample (n=90) was collected from exhumations following 7-35 years of burial and the second (n=30) was collected following successful investigations following routine case work. The study presents measurement of (1) the applicability of each of the methods: used and (2) the reliability with which the biographic parameters were assigned in each case. The results are discussed with reference to published assessments of methodological reliability regarding sex, age and-in particular-ancestry estimation. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Validation by numerical simulation of the behaviour of protective structures of machinery cabins subjected to standardized shocks

    Science.gov (United States)

    Dumitrache, P.; Goanţă, A. M.

    2017-08-01

    The ability of the cabins to insure the operator protection in the case of the shock loading that appears at the roll-over of the machine or when the cab is struck by the falling objects, it’s one of the most important performance criterions that it must comply by the machines and the mobile equipments. The experimental method provides the most accurate information on the behaviour of protective structures, but generates high costs due to experimental installations and structures which may be compromised during the experiments. In these circumstances, numerical simulation of the actual problem (mechanical shock applied to a strength structure) is a perfectly viable alternative, given that the hardware and software current performances provides the necessary support to obtain results with an acceptable level of accuracy. In this context, the paper proposes using FEA platforms for virtual testing of the actual strength structures of the cabins using their finite element models based on 3D models generated in CAD environments. In addition to the economic advantage above mentioned, although the results obtained by simulation using the finite element method are affected by a number of simplifying assumptions, the adequate modelling of the phenomenon can be a successful support in the design process of structures to meet safety performance criteria imposed by current standards. In the first section of the paper is presented the general context of the security performance requirements imposed by current standards on the cabins strength structures. The following section of the paper is dedicated to the peculiarities of finite element modelling in problems that impose simulation of the behaviour of structures subjected to shock loading. The final section of the paper is dedicated to a case study and to the future objectives.

  5. A Compact 5.5 GHz Band-Rejected UWB Antenna Using Complementary Split Ring Resonators

    Directory of Open Access Journals (Sweden)

    M. M. Islam

    2014-01-01

    Full Text Available A band-removal property employing microwave frequencies using complementary split ring resonators (CSRRs is applied to design a compact UWB antenna wishing for the rejection of some frequency band, which is meanwhile exercised by the existing wireless applications. The reported antenna comprises optimization of a circular radiating patch, in which slotted complementary SRRs are implanted. It is printed on low dielectric FR4 substrate material fed by a partial ground plane and a microstrip line. Validated results exhibit that the reported antenna shows a wide bandwidth covering from 3.45 to more than 12 GHz, with a compact dimension of 22 × 26 mm2, and VSWR < 2, observing band elimination of 5.5 GHz WLAN band.

  6. Handoff Management in Radio over Fiber 60 GHz Indoor Networks

    NARCIS (Netherlands)

    Bien, V.Q.

    2014-01-01

    Because of high data rate multimedia applications such as HD and UHDTV, online games, etc., the future home networks are expected to support short-range gigabit transmission. With the worldwide availability of 5 GHz spectrum at the 60 GHz band, it creates the opportunity for a promising air

  7. 77 FR 45558 - 4.9 GHz Band

    Science.gov (United States)

    2012-08-01

    ..., our rules currently require 4.9 GHz licensees to ``cooperate in the selection and use of channels in... directional and thus can be represented as narrow paths on a coordination map; in contrast, they note, the low-power, less- directional, geographically-dispersed links in a 4.9 GHz network must be represented as a...

  8. Towards low-cost gigabit wireless systems at 60 GHz

    NARCIS (Netherlands)

    Yang, Haibing

    2008-01-01

    The world-wide availability of the huge amount of license-free spectral space in the 60 GHz band provides wide room for gigabit-per-second (Gb/s) wireless applications. A commercial (read: low-cost) 60-GHz transceiver will, however, provide limited system performance due to the stringent link budget

  9. The 1.4 GHZ light curve of GRB 970508

    NARCIS (Netherlands)

    Galama, TJ; Wijers, RAMJ; Groot, PJ; Strom, RG; De Bruyn, AG; Kouveliotou, C; Robinson, CR; van Paradus, J

    1998-01-01

    We report on Westerbork 1.4 GHz radio observations of the radio counterpart to gamma-ray burst GRB 970508, between 0.80 and 138 days after this event. The 1.4 GHz light curve shows a transition from optically thick to thin emission between 39 and 54 days after the event. We derive the slope p of the

  10. 60 Gbit/s 400 GHz Wireless Transmission

    DEFF Research Database (Denmark)

    Yu, Xianbin; Asif, Rameez; Piels, Molly

    2015-01-01

    We experimentally demonstrate a 400 GHz carrier wireless transmission system with real-time capable detection and demonstrate transmission of a 60 Gbit/s signal derived from optical Nyquist channels in a 12.5 GHz ultra-dense wavelength division multiplexing (UD-WDM) grid and carrying QPSK...

  11. Rectenna Technology Program: Ultra light 2.45 GHz rectenna 20 GHz rectenna

    Science.gov (United States)

    Brown, William C.

    1987-01-01

    The program had two general objectives. The first objective was to develop the two plane rectenna format for space application at 2.45 GHz. The resultant foreplane was a thin-film, etched-circuit format fabricated from a laminate composed of 2 mil Kapton F sandwiched between sheets of 1 oz copper. The thin-film foreplane contains half wave dipoles, filter circuits, rectifying Schottky diode, and dc bussing lead. It weighs 160 grams per square meter. Efficiency and dc power output density were measured at 85% and 1 kw/sq m, respectively. Special testing techniques to measure temperature of circuit and diode without perturbing microwave operation using the fluoroptic thermometer were developed. A second objective was to investigate rectenna technology for use at 20 GHz and higher frequencies. Several fabrication formats including the thin-film scaled from 2.45 GHz, ceramic substrate and silk-screening, and monolithic were investigated, with the conclusion that the monolithic approach was the best. A preliminary design of the monolithic rectenna structure and the integrated Schottky diode were made.

  12. A New 95 GHz Methanol Maser Catalog. I. Data

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Wenjin; Xu, Ye; Lu, Dengrong; Ju, Binggang; Li, Yingjie [Purple Mountain Observatory, Chinese Academy of Science, Nanjing 210008 (China); Chen, Xi [Center for Astrophysics, GuangZhou University, Guangzhou 510006 (China); Ellingsen, Simon P., E-mail: wjyang@pmo.ac.cn, E-mail: xuye@pmo.ac.cn, E-mail: chenxi@shao.ac.cn [School of Physical Sciences, University of Tasmania, Hobart, Tasmania (Australia)

    2017-08-01

    The Purple Mountain Observatory 13.7 m radio telescope has been used to search for 95 GHz (8{sub 0}–7{sub 1}A{sup +}) class I methanol masers toward 1020 Bolocam Galactic Plane Survey (BGPS) sources, leading to 213 detections. We have compared the line width of the methanol and HCO{sup +} thermal emission in all of the methanol detections, and on that basis, we find that 205 of the 213 detections are very likely to be masers. This corresponds to an overall detection rate of 95 GHz methanol masers toward our BGPS sample of 20%. Of the 205 detected masers, 144 (70%) are new discoveries. Combining our results with those of previous 95 GHz methanol maser searches, a total of 481 95 GHz methanol masers are now known. We have compiled a catalog listing the locations and properties of all known 95 GHz methanol masers.

  13. Derivation of Z-R equation using Mie approach for a 77 GHz radar

    Science.gov (United States)

    Bertoldo, Silvano; Lucianaz, Claudio; Allegretti, Marco; Perona, Giovanni

    2017-04-01

    The ETSI (European Telecommunications Standards Institute) defines the frequency band around 77 GHz as dedicated to automatic cruise control long-range radars. This work aims to demonstrate that, with specific assumption and the right theoretical background it is also possible to use a 77 GHz as a mini weather radar and/or a microwave rain gauge. To study the behavior of a 77 GHz meteorological radar, since the raindrop size are comparable to the wavelength, it is necessary to use the general Mie scattering theory. According to the Mie formulation, the radar reflectivity factor Z is defined as a function of the wavelength on the opposite of Rayleigh approximation in which is frequency independent. Different operative frequencies commonly used in radar meteorology are considered with both the Rayleigh and Mie scattering theory formulation. Comparing them it is shown that with the increasing of the radar working frequency the use of Rayleigh approximation lead to an always larger underestimation of rain. At 77 GHz such underestimation is up to 20 dB which can be avoided with the full Mie theory. The crucial derivation of the most suited relation between the radar reflectivity factor Z and rainfall rate R (Z-R equation) is necessary to achieve the best Quantitative Precipitation Estimation (QPE) possible. Making the use of Mie scattering formulation from the classical electromagnetic theory and considering different radar working frequencies, the backscattering efficiency and the radar reflectivity factor have been derived from a wide range of rain rate using specific numerical routines. Knowing the rain rate and the corresponding reflectivity factor it was possible to derive the coefficients of the Z-R equation for each frequency with the least square method and to obtain the best coefficients for each frequency. The coefficients are then compared with the ones coming from the scientific literature. The coefficients of a 77 GHz weather radar are then obtained. A

  14. Development and validation of an observation tool for the assessment of nursing pain management practices in intensive care unit in a standardized clinical simulation setting.

    Science.gov (United States)

    Gosselin, Emilie; Bourgault, Patricia; Lavoie, Stephan; Coleman, Robin-Marie; Méziat-Burdin, Anne

    2014-12-01

    Pain management in the intensive care unit is often inadequate. There is no tool available to assess nursing pain management practices. The aim of this study was to develop and validate a measuring tool to assess nursing pain management in the intensive care unit during standardized clinical simulation. A literature review was performed to identify relevant components demonstrating optimal pain management in adult intensive care units and to integrate them in an observation tool. This tool was submitted to an expert panel and pretested. It was then used to assess pain management practice during 26 discrete standardized clinical simulation sessions with intensive care nurses. The Nursing Observation Tool for Pain Management (NOTPaM) contains 28 statements grouped into 8 categories, which are grouped into 4 dimensions: subjective assessment, objective assessment, interventions, and reassessment. The tool's internal consistency was calculated at a Cronbach's alpha of 0.436 for the whole tool; the alpha varies from 0.328 to 0.518 for each dimension. To evaluate the inter-rater reliability, intra-class correlation coefficient was used, which was calculated at 0.751 (p nurses' pain management in a standardized clinical simulation. The NOTPaM is the first tool created for this purpose. Copyright © 2014 American Society for Pain Management Nursing. Published by Elsevier Inc. All rights reserved.

  15. Validation of standard ASTM F2732 and comparison with ISO 11079 with respect to comfort temperature ratings for cold protective clothing.

    Science.gov (United States)

    Gao, Chuansi; Lin, Li-Yen; Halder, Amitava; Kuklane, Kalev; Holmér, Ingvar

    2015-01-01

    American standard ASTM F2732 estimates the lowest environmental temperature for thermal comfort for cold weather protective clothing. International standard ISO 11079 serves the same purpose but expresses cold stress in terms of required clothing insulation for a given cold climate. The objective of this study was to validate and compare the temperature ratings using human subject tests at two levels of metabolic rates (2 and 4 MET corresponding to 116.4 and 232.8 W/m(2)). Nine young and healthy male subjects participated in the cold exposure at 3.4 and -30.6 °C. The results showed that both standards predict similar temperature ratings for an intrinsic clothing insulation of 1.89 clo and for 2 MET activity. The predicted temperature rating for 2 MET activity is consistent with test subjects' thermophysiological responses, perceived thermal sensation and thermal comfort. For 4 MET activity, however, the whole body responses were on the cold side, particularly the responses of the extremities. ASTM F2732 is also limited due to its omission and simplification of three climatic variables (air velocity, radiant temperature and relative humidity) and exposure time in the cold which are of practical importance. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  16. 25 Gbit/s QPSK Hybrid Fiber-Wireless Transmission in the W-Band (75–110 GHz) With Remote Antenna Unit for In-Building Wireless Networks

    DEFF Research Database (Denmark)

    Pang, Xiaodan; Caballero Jambrina, Antonio; Dogadaev, Anton Konstantinovich

    2012-01-01

    In this paper, we demonstrate a photonic up-converted 25 Gbit/s fiber-wireless quadrature phase shift-keying (QPSK) data transmission link at the W-band (75–110 GHz). By launching two free-running lasers spaced at 87.5 GHz into a standard single-mode fiber (SSMF) at the central office, a W...

  17. 47 CFR 25.224 - Protection of receive-only earth stations in the 17/24 GHz BSS.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Protection of receive-only earth stations in the 17/24 GHz BSS. 25.224 Section 25.224 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES SATELLITE COMMUNICATIONS Technical Standards § 25.224 Protection of...

  18. 47 CFR 25.262 - Licensing and domestic coordination requirements for 17/24 GHz BSS space stations.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Licensing and domestic coordination requirements for 17/24 GHz BSS space stations. 25.262 Section 25.262 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES SATELLITE COMMUNICATIONS Technical Standards § 25.262...

  19. 47 CFR 25.256 - Special Requirements for operations in the 3.65-3.7 GHz band.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Special Requirements for operations in the 3.65-3.7 GHz band. 25.256 Section 25.256 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES SATELLITE COMMUNICATIONS Technical Standards § 25.256 Special Requirements for...

  20. An administrative data validation study of the accuracy of algorithms for identifying rheumatoid arthritis: the influence of the reference standard on algorithm performance.

    Science.gov (United States)

    Widdifield, Jessica; Bombardier, Claire; Bernatsky, Sasha; Paterson, J Michael; Green, Diane; Young, Jacqueline; Ivers, Noah; Butt, Debra A; Jaakkimainen, R Liisa; Thorne, J Carter; Tu, Karen

    2014-06-23

    We have previously validated administrative data algorithms to identify patients with rheumatoid arthritis (RA) using rheumatology clinic records as the reference standard. Here we reassessed the accuracy of the algorithms using primary care records as the reference standard. We performed a retrospective chart abstraction study using a random sample of 7500 adult patients under the care of 83 family physicians contributing to the Electronic Medical Record Administrative data Linked Database (EMRALD) in Ontario, Canada. Using physician-reported diagnoses as the reference standard, we computed and compared the sensitivity, specificity, and predictive values for over 100 administrative data algorithms for RA case ascertainment. We identified 69 patients with RA for a lifetime RA prevalence of 0.9%. All algorithms had excellent specificity (>97%). However, sensitivity varied (75-90%) among physician billing algorithms. Despite the low prevalence of RA, most algorithms had adequate positive predictive value (PPV; 51-83%). The algorithm of "[1 hospitalization RA diagnosis code] or [3 physician RA diagnosis codes with ≥1 by a specialist over 2 years]" had a sensitivity of 78% (95% CI 69-88), specificity of 100% (95% CI 100-100), PPV of 78% (95% CI 69-88) and NPV of 100% (95% CI 100-100). Administrative data algorithms for detecting RA patients achieved a high degree of accuracy amongst the general population. However, results varied slightly from our previous report, which can be attributed to differences in the reference standards with respect to disease prevalence, spectrum of disease, and type of comparator group.

  1. Construction of an integrated down-converter for operation at 200 GHz

    International Nuclear Information System (INIS)

    Digby, J.W.

    1999-05-01

    There is currently considerable interest in the part of the electromagnetic spectrum known as the terahertz region (100 GHz to 10 THz). Traditionally, terahertz radiation was the preserve of specialist applications in astronomy, atmospheric studies and plasma diagnostics. However, potential or actual applications in such diverse fields as medicine, security, communications and military applications are now emerging. At present there are very few devices and systems that operate in this spectral region and those which exist are expensive and difficult to manufacture. For the potential of terahertz radiation to be realised by industry, a low-cost (i.e. 'manufacturable') method of constructing terahertz systems is needed; new methods of generating radiation at terahertz frequencies are also urgently required. This thesis presents the development of a novel technique for producing passive and active devices and systems for use at terahertz frequencies. This novel approach utilises standard semiconductor techniques to fabricate metal-pipe waveguides directly onto semiconductor wafers. As standard semiconductor techniques are used, it provides a possible low-cost and highly manufacturable method of producing terahertz devices and systems. The key processes that are needed to produce components and devices for terahertz systems have been developed and presented in this work. Metal-pipe rectangular waveguides for use at W-band (70 GHz - 110 GHz) and G-band (140 GHz - 220 GHz) have been fabricated and S-parameter measurements have been performed on them using a specially designed test fixture. The measured attenuation for these waveguides is approximately 0.2 dB to 5 dB per guide wavelength for W-band and 0.6 dB per guide wavelength for G-band; these results suggest that these components could be used in practical systems. A method of interfacing with terahertz systems and free-space is needed in real applications, so a horn antenna has been designed which can be

  2. Validation of a single nucleotide polymorphism (SNP) typing assay with 49 SNPs for forensic genetic testing in a laboratory accredited according to the ISO 17025 standard

    DEFF Research Database (Denmark)

    Børsting, Claus; Rockenbauer, Eszter; Morling, Niels

    2009-01-01

    cases and 33 twin cases were typed at least twice for the 49 SNPs. All electropherograms were analysed independently by two expert analysts prior to approval. Based on these results, detailed guidelines for analysis of the SBE products were developed. With these guidelines, the peak height ratio...... of a heterozygous allele call or the signal to noise ratio of a homozygous allele call is compared with previously obtained ratios. A laboratory protocol for analysis of SBE products was developed where allele calls with unusual ratios were highlighted to facilitate the analysis of difficult allele calls......A multiplex assay with 49 autosomal single nucleotide polymorphisms (SNPs) developed for human identification was validated for forensic genetic casework and accredited according to the ISO 17025 standard. The multiplex assay was based on the SNPforID 52plex SNP assay [J.J. Sanchez, C. Phillips, C...

  3. Organizational strategy use in children aged 5-7: standardization and validity of the Rey Complex Figure Organizational Strategy Score (RCF-OSS).

    Science.gov (United States)

    Martens, R; Hurks, P P M; Jolles, J

    2014-01-01

    This study investigated psychometric properties (standardization and validity) of the Rey Complex Figure Organizational Strategy Score (RCF-OSS) in a sample of 217 healthy children aged 5-7 years. Our results showed that RCF-OSS performance changes significantly between 5 and 7 years of age. While most 5-year-olds used a local approach when copying the Rey-Osterrieth Complex Figure (ROCF), 7-year-olds increasingly adopted a global approach. RCF-OSS performance correlated significantly, but moderately with measures of ROCF accuracy, executive functioning (fluency, working memory, reasoning), and non-executive functioning (visual-motor integration, visual attention, processing speed, numeracy). These findings seem to indicate that RCF-OSS performance reflects a range of cognitive skills at 5 to 7 years of age, including aspects of executive and non-executive functioning.

  4. The 17 GHz active region number

    Energy Technology Data Exchange (ETDEWEB)

    Selhorst, C. L.; Pacini, A. A. [IP and D-Universidade do Vale do Paraíba-UNIVAP, São José dos Campos (Brazil); Costa, J. E. R. [CEA, Instituto Nacional de Pesquisas Espaciais, São José dos Campos (Brazil); Giménez de Castro, C. G.; Valio, A. [CRAAM, Universidade Presbiteriana Mackenzie, São Paulo (Brazil); Shibasaki, K., E-mail: caius@univap.br [Nobeyama Solar Radio Observatory/NAOJ, Minamisaku, Nagano 384-1305 (Japan)

    2014-08-01

    We report the statistics of the number of active regions (NAR) observed at 17 GHz with the Nobeyama Radioheliograph between 1992, near the maximum of cycle 22, and 2013, which also includes the maximum of cycle 24, and we compare with other activity indexes. We find that NAR minima are shorter than those of the sunspot number (SSN) and radio flux at 10.7 cm (F10.7). This shorter NAR minima could reflect the presence of active regions generated by faint magnetic fields or spotless regions, which were a considerable fraction of the counted active regions. The ratio between the solar radio indexes F10.7/NAR shows a similar reduction during the two minima analyzed, which contrasts with the increase of the ratio of both radio indexes in relation to the SSN during the minimum of cycle 23-24. These results indicate that the radio indexes are more sensitive to weaker magnetic fields than those necessary to form sunspots, of the order of 1500 G. The analysis of the monthly averages of the active region brightness temperatures shows that its long-term variation mimics the solar cycle; however, due to the gyro-resonance emission, a great number of intense spikes are observed in the maximum temperature study. The decrease in the number of these spikes is also evident during the current cycle 24, a consequence of the sunspot magnetic field weakening in the last few years.

  5. Whole-body 35-GHz security scanner

    Science.gov (United States)

    Appleby, Roger; Anderton, Rupert N.; Price, Sean; Sinclair, Gordon N.; Coward, Peter R.

    2004-08-01

    A 35GHz imager designed for Security Scanning has been previously demonstrated. That imager was based on a folded conical scan technology and was constructed from low cost materials such as expanded polystyrene and printed circuit board. In conjunction with an illumination chamber it was used to collect indoor imagery of people with weapons and contraband hidden under their clothing. That imager had a spot size of 20mm and covered a field of view of 20 x 10 degrees that partially covered the body of an adult from knees to shoulders. A new variant of this imager has been designed and constructed. It has a field of view of 36 x 18 degrees and is capable of covering the whole body of an adult. This was achieved by increasing the number of direct detection receivers from the 32 used in the previous design to 58, and by implementing an improved optical design. The optics consist of a front grid, a polarisation device which converts linear to circular polarisation and a rotating scanner. This new design uses high-density expanded polystyrene as a correcting element on the back of the front grid. This gives an added degree of freedom that allows the optical design to be diffraction limited over a very wide field of view. Obscuration by the receivers and associated components is minimised by integrating the post detection electronics at the receiver array.

  6. Driver kinematic and muscle responses in braking events with standard and reversible pre-tensioned restraints: validation data for human models.

    Science.gov (United States)

    Osth, Jonas; Olafsdóttir, Jóna Marín; Davidsson, Johan; Brolin, Karin

    2013-11-01

    The objectives of this study are to generate validation data for human models intended for simulation of occupant kinematics in a pre-crash phase, and to evaluate the effect of an integrated safety system on driver kinematics and muscle responses. Eleven male and nine female volunteers, driving a passenger car on ordinary roads, performed maximum voluntary braking; they were also subjected to autonomous braking events with both standard and reversible pre-tensioned restraints. Kinematic data was acquired through film analysis, and surface electromyography (EMG) was recorded bilaterally for muscles in the neck, the upper extremities, and lumbar region. Maximum voluntary contractions (MVCs) were carried out in a driving posture for normalization of the EMG. Seat belt positions, interaction forces, and seat indentions were measured. During normal driving, all muscle activity was below 5% of MVC for females and 9% for males. The range of activity during steady state braking for males and females was 13-44% in the cervical and lumbar extensors, while antagonistic muscles showed a co-contraction of 2.3-19%. Seat belt pre-tension affects both the kinematic and muscle responses of drivers. In autonomous braking with standard restraints, muscle activation occurred in response to the inertial load. With pre-tensioned seat belts, EMG onset occurred earlier; between 71 ms and 176 ms after belt pre-tension. The EMG onset times decreased with repeated trials and were shorter for females than for males. With the results from this study, further improvement and validation of human models that incorporate active musculature will be made possible.

  7. Optimization, validation and standardization of a method of measuring the radiochemical purity of 99mTc-HMDP in Necker hospital

    International Nuclear Information System (INIS)

    Dumont, A.; Izembart, M.; Barritault, L.

    1997-01-01

    By the end of 1996, the tests of the radiochemical purity (RCP) of preparation of HMDP- 99m Tc at Necker hospital were effected by means of 'Tech-Kit' technique which allowed making evident only one radiochemical impurity, the free TcO 4 - . So, the aim of this work has been the search for another technique able to detect also the reduced hydrolyzed 99m Tc, and then, to optimize, validate and standardize this new technique. Several methods have been tested and compared on different points (the chemical species identified, practical difficulties, duration, reproducibility) in order to chose 'the best' one, consisting in associating two TLC (migration time, 3 minutes): - TLC no.1, ITLC-SG/Methyl-ethyl-ketone; - TLC no.2, ITLC-SG/1M Sodium acetate. This method has been subsequently: - optimized, concerning the quantity of deposed sampling, way of deposit drying, migration range, reading protocol by radio-chromatograph; - validated, by verifying the migration of radiochemical impurities by means of controls and by evaluating its sensitivity; - standardized, by defining the interest zones for interpreting the radio-chromatograms, by evaluating the reproducibility and by calculating the 'normal values' of RCP percentages. This method has been adopted as routine and with current recoil (40 preparations) and our conditions of realizations, the extreme values of the percentages obtained for the impurity zones of interests, have been the following: - TcO 4 - zone, [0.39%-1.07%]; - hydrolyzed reduced Tc zone, [0.96%-5.09%]. By taking into account their distribution we calculated a minimum RCP value of 94% to accept the preparation (the RCP being defined as equal to 100% - % TcO 4 - % hydrolyzed reduced Tc)

  8. Validity and reliability of 3D US for the detection of erosions in patients with rheumatoid arthritis using MRI as the gold standard

    DEFF Research Database (Denmark)

    Ellegaard, K; Bliddal, H; Møller Døhn, U

    2014-01-01

    PURPOSE: To test the reliability and validity of a 3D US erosion score in RA using MRI as the gold standard. MATERIALS AND METHODS: RA patients were examined with 3D US and 3 T MRI over the 2nd and 3rd metacarpophalangeal joints. 3D blocks were evaluated by two investigators. The erosions were...... estimated according to a semi-quantitative score (SQS) (0 - 3) and a quantitative score (QS) (mm²). MRI was evaluated according to the RAMRIS score. For the estimation of reliability, intra-class correlation coefficients (ICC) were used. Validity was tested using Spearman's rho (rs). The sensitivity...... and specificity were also calculated. RESULTS: 28 patients with RA were included. The ICC for the inter-observer reliability in the QS was 0.41 and 0.13 for the metacarpal bone and phalangeal bone, respectively, and 0.86 and 0.16, respectively, in the SQS.  The ICC for the intra-observer reliability in the QS...

  9. On the Use of a 77 GHz Automotive Radar as a Microwave Rain Gauge

    Directory of Open Access Journals (Sweden)

    S. Bertoldo

    2018-02-01

    Full Text Available The European Telecommunications Standards Institute (ETSI defines the frequency band of 77 GHz (W-band as the one dedicated to automatic cruise control long-range radars. A car can be thought as a moving integrated weather sensor since it can provide meteorological information exploiting the sensors installed on board. This work presents the preliminary analysis of how a 77 GHz mini radar can be used as a short range microwave rain gauge. After the discussion of the Mie scattering formulation applied to a microwave rain gauge working in the W-band, the proposal of a new Z-R equation to be used for correct rain estimation is given. Atmospheric attenuation and absorption are estimated taking into account the ITU-T recommendations. Functional requirements in adapting automatic cruise control long-range radar to a microwave rain gauge are analyzed. The technical specifications are determined in order to meet the functional requirements.

  10. A program of high power microwave source research and development from 8 GHz to 600 GHz

    International Nuclear Information System (INIS)

    Granatstein, V.L.; Antonsen, T.M. Jr.; Bidwell, S.; Booske, J.; Carmel, Y.; Destler, W.W.; Kehs, R.A.; Latham, P.E.; Levush, B.; Lou, W.R.; Mayergoyz, I.D.; Minami, K.; Radack, D.J.

    1990-01-01

    We review research results both on a plasma filled, backward wave oscillator (BWO), and on a free electron laser (FEL) driven by a sheet electron beam. Recently, it was demonstrated that a plasma filled BWO driven by an intense relativistic electron beam can generate hundreds of megawatts of microwave radiation at an unusually high efficiency of 40% compared with a typical efficiency of ∼10% in a BWO without a background plasma. Furthermore, the enhanced efficiency can be maintained even for large electron beam currents approaching the vacuum space charge limiting current, and we anticipate this might hold even for larger current values. Theoretical studies and numerical simulations indicate that the enhanced efficiency as well as a lower value for the start oscillation current in the linear regime may be due to the finite length of the BWO circuit coupled with modification of the dispersion relation due to the background plasma. In the case of our FEL studies, we present designs for a 1 MW, CW, tapered FEL amplifier operating at frequencies of 280 GHz and 560 GHz. A short wiggler period (ell w ∼ 1 cm) is combined with a sheet beam of electrons having energy ∼1 MeV. Depressed collector techniques would allow the main power supply rating to be reduced to ∼200 kV. Efficient sheet beam transport (>99%) has been demonstrated through 10 wiggler periods, and transport through 60 wiggler periods is currently under study. Finally, plans for a proof-of-principle tapered FEL amplifier experiment at 94 GHz are presented. 8 refs., 7 figs

  11. The 30/20 GHz communications system functional requirements

    Science.gov (United States)

    Siperko, C. M.; Frankfort, M.; Markham, R.; Wall, M.

    1981-01-01

    The characteristics of 30/20 GHz usage in satellite systems to be used in support of projected communication requirements of the 1990's are defined. A requirements analysis which develops projected market demand for satellite services by general and specialized carriers and an analysis of the impact of propagation and system constraints on 30/20 GHz operation are included. A set of technical performance characteristics for the 30/20 GHz systems which can serve the resulting market demand and the experimental program necessary to verify technical and operational aspects of the proposed systems is also discussed.

  12. Packaging of microwave integrated circuits operating beyond 100 GHz

    Science.gov (United States)

    Samoska, L.; Daniel, E.; Sokolov, V.; Sommerfeldt, S.; Bublitz, J.; Olson, K.; Gilbert, B.; Chow, D.

    2002-01-01

    Several methods of packaging high speed (75-330 GHz) InP HEMT MMIC devices are discussed. Coplanar wirebonding is presented with measured insertion loss of less than 0.5dB and return loss better than -17 dB from DC to 110 GHz. A motherboard/daughterboard packaging scheme is presented which supports minimum loss chains of MMICs using this coplanar wirebonding method. Split waveguide block packaging approaches are presented in G-band (140-220 GHz) with two types of MMIC-waveguide transitions: E-plane probe andantipodal finline.

  13. A study of 60 GHz intersatellite link applications

    Science.gov (United States)

    Anzic, G.; Connolly, D. J.; Haugland, E. J.; Kosmahl, H. G.; Chitwood, J. S.

    Applications of intersatellite links operating at 60 GHz are reviewed. Likely scenarios, ranging from transmission of moderate and high data rates over long distances to low data rates over short distances are examined. A limited parametric tradeoff is performed with system variables such as radiofrequency power, receiver noise temperature, link distance, data rate, and antenna size. Present status is discussed and projections are given for both electron tube and solid state transmitter technologies. Monolithic transmit and receive module technology, already under development at 20 to 30 GHz, is reviewed and its extension to 60 GHz, and possible applicability is discussed.

  14. A study of 60 GHz intersatellite link applications

    Science.gov (United States)

    Anzic, G.; Connolly, D. J.; Haugland, E. J.; Kosmahl, H. G.; Chitwood, J. S.

    1983-01-01

    Applications of intersatellite links operating at 60 GHz are reviewed. Likely scenarios, ranging from transmission of moderate and high data rates over long distances to low data rates over short distances are examined. A limited parametric tradeoff is performed with system variables such as radiofrequency power, receiver noise temperature, link distance, data rate, and antenna size. Present status is discussed and projections are given for both electron tube and solid state transmitter technologies. Monolithic transmit and receive module technology, already under development at 20 to 30 GHz, is reviewed and its extension to 60 GHz, and possible applicability is discussed.

  15. Measurement of the 60 GHz ECR ion source using megawatt magnets - SEISM magnetic field map

    International Nuclear Information System (INIS)

    Marie-Jeanne, M.; Jacob, J.; Lamy, T.; Latrasse, L.; Debray, F.; Matera, J.; Pfister, R.; Trophine, C.

    2012-01-01

    LPSC has developed a 60 GHz Electron Cyclotron Resonance (ECR) Ion Source prototype called SEISM. The magnetic structure uses resistive poly-helix coils designed in collaboration with the French National High Magnetic Fields Facility (LNCMI) to produce a CUSP magnetic configuration. A dedicated test bench and appropriate electrical and water cooling environments were built to study the validity of the mechanics, the thermal behaviour and magnetic field characteristics obtained at various current intensities. During the last months, measurements were performed for several magnetic configurations, with up to 7000 A applied on the injection and extraction coils sets. The magnetic field achieved at 13000 A is expected to allow 28 GHz ECR condition, so by extrapolation 60 GHz should be possible at about 28000 A. However, cavitation issues that appeared around 7000 A are to be solved before carrying on with the tests. This contribution will recall some of the crucial steps in the prototype fabrication, and show preliminary results from the measurements at 7000 A. Possible explanations for the differences observed between the results and the simulation will be given. The paper is followed by the slides of the presentation. (authors)

  16. Simultaneous validation of the SunTech CT40 automated blood pressure measurement device by the 1993 British Hypertension Society protocol and the Association for the Advancement of Medical Instrumentation/International Organization for Standardization 81060-2: 2013 standard.

    Science.gov (United States)

    Polo Friz, Hernan; Punzi, Veronica; Petri, Francesco; Orlandi, Riccardo; Maggiolini, Daniele; Polo Friz, Melisa; Primitz, Laura; Vighi, Giuseppe

    2017-10-01

    This study aimed to perform a simultaneous, third-party, independent validation of the oscillometric SunTech CT40 device for blood pressure (BP) measurement, according to the 1993 protocol of the British Hypertension Society and the standard of the Association for the Advancement of Medical Instrumentation (AAMI)/the International Organization for Standardization (ISO) 81060-2:2013. Patient recruitment, study procedures, and data analysis followed the recommendations stated by the protocols. The study was approved by the institutional review board. A total of 94 participants were included, 52 (55.3%) women, mean±SD age: 63.1±18.0 years, mean±SD arm circumference: 35.0±9.0 cm. The average of observers' entry BPs was 146.9±37.2 mmHg for systolic blood pressure (SBP) and 82.2±22.1 mmHg for diastolic blood pressure (DBP). Differences between the standard measurement and the test device within 5, 10, and 15 mmHg, for the better observer, were 79.4, 96.5, and 100.0% for SBP and 82.6, 97.5, and 100.0% for DBP, respectively. The mean±SD differences between the readings obtained using the test device and those obtained by the observers (AAMI/ISO 81060-2:2013 standard criterion 1) were 0.3±5.0 mmHg (SBP) and -0.8±4.3 mmHg (DBP), and the mean±SD differences between average of reference readings and average of test device readings in each patient (criterion 2) were 0.3±3.9 and -0.8±3.5 mmHg for SBP and DBP, respectively. The CT40 BP device achieved A/A grade of the British Hypertension Society protocol and fulfilled the requirements (criteria 1 and 2) of the AAMI/ISO standard. CT40 can be recommended for BP measurement in adults.

  17. Analysis of Item-Level Bias in the Bayley-III Language Subscales: The Validity and Utility of Standardized Language Assessment in a Multilingual Setting.

    Science.gov (United States)

    Goh, Shaun K Y; Tham, Elaine K H; Magiati, Iliana; Sim, Litwee; Sanmugam, Shamini; Qiu, Anqi; Daniel, Mary L; Broekman, Birit F P; Rifkin-Graboi, Anne

    2017-09-18

    The purpose of this study was to improve standardized language assessments among bilingual toddlers by investigating and removing the effects of bias due to unfamiliarity with cultural norms or a distributed language system. The Expressive and Receptive Bayley-III language scales were adapted for use in a multilingual country (Singapore). Differential item functioning (DIF) was applied to data from 459 two-year-olds without atypical language development. This involved investigating if the probability of success on each item varied according to language exposure while holding latent language ability, gender, and socioeconomic status constant. Associations with language, behavioral, and emotional problems were also examined. Five of 16 items showed DIF, 1 of which may be attributed to cultural bias and another to a distributed language system. The remaining 3 items favored toddlers with higher bilingual exposure. Removal of DIF items reduced associations between language scales and emotional and language problems, but improved the validity of the expressive scale from poor to good. Our findings indicate the importance of considering cultural and distributed language bias in standardized language assessments. We discuss possible mechanisms influencing performance on items favoring bilingual exposure, including the potential role of inhibitory processing.

  18. Architecture for a 1-GHz Digital RADAR

    Science.gov (United States)

    Mallik, Udayan

    2011-01-01

    An architecture for a Direct RF-digitization Type Digital Mode RADAR was developed at GSFC in 2008. Two variations of a basic architecture were developed for use on RADAR imaging missions using aircraft and spacecraft. Both systems can operate with a pulse repetition rate up to 10 MHz with 8 received RF samples per pulse repetition interval, or at up to 19 kHz with 4K received RF samples per pulse repetition interval. The first design describes a computer architecture for a Continuous Mode RADAR transceiver with a real-time signal processing and display architecture. The architecture can operate at a high pulse repetition rate without interruption for an infinite amount of time. The second design describes a smaller and less costly burst mode RADAR that can transceive high pulse repetition rate RF signals without interruption for up to 37 seconds. The burst-mode RADAR was designed to operate on an off-line signal processing paradigm. The temporal distribution of RF samples acquired and reported to the RADAR processor remains uniform and free of distortion in both proposed architectures. The majority of the RADAR's electronics is implemented in digital CMOS (complementary metal oxide semiconductor), and analog circuits are restricted to signal amplification operations and analog to digital conversion. An implementation of the proposed systems will create a 1-GHz, Direct RF-digitization Type, L-Band Digital RADAR--the highest band achievable for Nyquist Rate, Direct RF-digitization Systems that do not implement an electronic IF downsample stage (after the receiver signal amplification stage), using commercially available off-the-shelf integrated circuits.

  19. 1.3 GHz superconducting RF cavity program at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Ginsburg, C.M.; Arkan, T.; Barbanotti, S.; Carter, H.; Champion, M.; Cooley, L.; Cooper, C.; Foley, M.; Ge, M.; Grimm, C.; Harms, E.; /Fermilab

    2011-03-01

    At Fermilab, 9-cell 1.3 GHz superconducting RF (SRF) cavities are prepared, qualified, and assembled into cryomodules (CMs) for Project X, an International Linear Collider (ILC), or other future projects. The 1.3 GHz SRF cavity program includes targeted R&D on 1-cell 1.3 GHz cavities for cavity performance improvement. Production cavity qualification includes cavity inspection, surface processing, clean assembly, and one or more cryogenic low-power CW qualification tests which typically include performance diagnostics. Qualified cavities are welded into helium vessels and are cryogenically tested with pulsed high-power. Well performing cavities are assembled into cryomodules for pulsed high-power testing in a cryomodule test facility, and possible installation into a beamline. The overall goals of the 1.3 GHz SRF cavity program, supporting facilities, and accomplishments are described.

  20. 45-110 GHz Quad-Ridge Horn With Stable Gain and Symmetric Beam

    Science.gov (United States)

    Manafi, Sara; Al-Tarifi, Muhannad; Filipovic, Dejan S.

    2017-09-01

    A quad-ridge horn antenna with stabilized gain and minimum difference between Eand H-plane half-power beamwidths (HPBWs) is demonstrated for operation over 45-110 GHz bandwidth. Multistep flaring and corrugations on a finite ground plane are applied to obtain stable radiation patterns with 16-dBi minimum gain over the entire range. The computational studies are validated through measurements of a 3-D printed prototype using the direct metal laser sintering (DMLS) process. Accurate fabrication with achieved surface roughness of DMLS is a viable fabrication process for wideband horn antennas at millimeter-wave frequencies.

  1. Numerical Simulation of MIG for 42 GHz, 200 kW Gyrotron

    Science.gov (United States)

    Singh, Udaybir; Bera, Anirban; Kumar, Narendra; Purohit, L. P.; Sinha, Ashok K.

    2010-06-01

    A triode type magnetron injection gun (MIG) of a 42 GHz, 200 kW gyrotron for an Indian TOKAMAK system is designed by using the commercially available code EGUN. The operating voltages of the modulating anode and the accelerating anode are 29 kV and 65 kV respectively. The operating mode of the gyrotron is TE03 and it is operated in fundamental harmonic. The simulated results of MIG obtained with the EGUN code are validated with another trajectory code TRAK.

  2. A compact 5.5 GHz band-rejected UWB antenna using complementary split ring resonators.

    Science.gov (United States)

    Islam, M M; Faruque, M R I; Islam, M T

    2014-01-01

    A band-removal property employing microwave frequencies using complementary split ring resonators (CSRRs) is applied to design a compact UWB antenna wishing for the rejection of some frequency band, which is meanwhile exercised by the existing wireless applications. The reported antenna comprises optimization of a circular radiating patch, in which slotted complementary SRRs are implanted. It is printed on low dielectric FR4 substrate material fed by a partial ground plane and a microstrip line. Validated results exhibit that the reported antenna shows a wide bandwidth covering from 3.45 to more than 12 GHz, with a compact dimension of 22 × 26 mm(2), and VSWR WLAN band.

  3. Feasibility of automotive radar at frequencies beyond 100 GHz

    OpenAIRE

    Köhler, Mike; Hasch, Jürgen; Blöcher, Hans Ludwig; Schmidt, Lorenz-Peter

    2014-01-01

    Radar sensors are used widely in modern driver assistance systems. Available sensors nowadays often operate in the 77 GHz band and can accurately provide distance, velocity, and angle information about remote objects. Increasing the operation frequency allows improving the angular resolution and accuracy. In this paper, the technical feasibility to move the operation frequency beyond 100 GHz is discussed, by investigating dielectric properties of radome materials, the attenuation of rain and ...

  4. Multiparty quantum secret sharing based on GHZ states

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Tzonelih; Hwang, Cheng-Chieh [Department of Computer Science and Information Engineering, National Cheng Kung University, Tainan, 701 Taiwan (China); Li, Chuan-Ming, E-mail: hwangtl@ismail.csie.ncku.edu.tw [Department of Information Management, Shu-Zen College of Medicine and Management, Kaohsiung, 821 Taiwan (China)

    2011-04-15

    Gao (2009 Commun. Theor. Phys. 52 421-4) has proposed an efficient multiparty quantum secret sharing (MQSS) with two-photon three-dimensional Einstein-Podolsky-Rosen (EPR) pairs. This work shows that a similar idea can also be used to construct an MQSS using the Greenberger-Horne-Zeilinger (GHZ) states. Compared to other MQSSs using GHZ-related states, the newly proposed protocol is more efficient in the aspect of qubit utilization.

  5. Design of 340 GHz 2× and 4× Sub-Harmonic Mixers Using Schottky Barrier Diodes in Silicon-Based Technology

    Directory of Open Access Journals (Sweden)

    Chao Liu

    2015-05-01

    Full Text Available This paper presents the design of terahertz 2× and 4× sub-harmonic down-mixers using Schottky Barrier Diodes fabricated in standard 0.13 μm SiGe BiCMOS technology. The 340 GHz sub-harmonic mixers (SHMs are designed based on anti-parallel-diode-pairs (APDPs. With the 2nd and 4th harmonic, local oscillator (LO frequencies of 170 GHz and 85 GHz are used to pump the two 340 GHz SHMs. With LO power of 7 dBm, the 2× SHM exhibits a conversion loss of 34.5–37 dB in the lower band (320–340 GHz and 35.5–41 dB in the upper band (340–360 GHz; with LO power of 9 dBm, the 4× SHM exhibits a conversion loss of 39–43 dB in the lower band (320–340 GHz and 40–48 dB in the upper band (340–360 GHz. The measured input 1-dB conversion gain compression point for the 2× and 4× SHMs are −8 dBm and −10 dBm at 325 GHz, respectively. The simulated LO-IF (intermediate frequency isolation of the 2× SHM is 21.5 dB, and the measured LO-IF isolation of the 4× SHM is 32 dB. The chip areas of the 2× and 4× SHMs are 330 μm × 580 μm and 550 μm × 610 μm, respectively, including the testing pads.

  6. Caracterisation, modelisation et validation du transfert radiatif d'atmospheres non standard; impact sur les corrections atmospheriques d'images de teledetection

    Science.gov (United States)

    Zidane, Shems

    This study is based on data acquired with an airborne multi-altitude sensor on July 2004 during a nonstandard atmospheric event in the region of Saint-Jean-sur-Richelieu, Quebec. By non-standard atmospheric event we mean an aerosol atmosphere that does not obey the typical monotonic, scale height variation employed in virtually all atmospheric correction codes. The surfaces imaged during this field campaign included a diverse variety of targets : agricultural land, water bodies, urban areas and forests. The multi-altitude approach employed in this campaign allowed us to better understand the altitude dependent influence of the atmosphere over the array of ground targets and thus to better characterize the perturbation induced by a non-standard (smoke) plume. The transformation of the apparent radiance at 3 different altitudes into apparent reflectance and the insertion of the plume optics into an atmospheric correction model permitted an atmospheric correction of the apparent reflectance at the two higher altitudes. The results showed consistency with the apparent validation reflectances derived from the lowest altitude radiances. This approach effectively confirmed the accuracy of our non-standard atmospheric correction approach. This test was particularly relevant at the highest altitude of 3.17 km : the apparent reflectances at this altitude were above most of the plume and therefore represented a good test of our ability to adequately correct for the influence of the perturbation. Standard atmospheric disturbances are obviously taken into account in most atmospheric correction models, but these are based on monotonically decreasing aerosol variations with increasing altitude. When the atmospheric radiation is affected by a plume or a local, non-standard pollution event, one must adapt the existing models to the radiative transfer constraints of the local perturbation and to the reality of the measurable parameters available for ingestion into the model. The

  7. Nuclear Energy -- Knowledge Base for Advanced Modeling and Simulation (NE-KAMS) Code Verification and Validation Data Standards and Requirements: Fluid Dynamics Version 1.0

    Energy Technology Data Exchange (ETDEWEB)

    Greg Weirs; Hyung Lee

    2011-09-01

    V&V and UQ are the primary means to assess the accuracy and reliability of M&S and, hence, to establish confidence in M&S. Though other industries are establishing standards and requirements for the performance of V&V and UQ, at present, the nuclear industry has not established such standards or requirements. However, the nuclear industry is beginning to recognize that such standards are needed and that the resources needed to support V&V and UQ will be very significant. In fact, no single organization has sufficient resources or expertise required to organize, conduct and maintain a comprehensive V&V and UQ program. What is needed is a systematic and standardized approach to establish and provide V&V and UQ resources at a national or even international level, with a consortium of partners from government, academia and industry. Specifically, what is needed is a structured and cost-effective knowledge base that collects, evaluates and stores verification and validation data, and shows how it can be used to perform V&V and UQ, leveraging collaboration and sharing of resources to support existing engineering and licensing procedures as well as science-based V&V and UQ processes. The Nuclear Energy Knowledge base for Advanced Modeling and Simulation (NE-KAMS) is being developed at the Idaho National Laboratory in conjunction with Bettis Laboratory, Sandia National Laboratories, Argonne National Laboratory, Utah State University and others with the objective of establishing a comprehensive and web-accessible knowledge base to provide V&V and UQ resources for M&S for nuclear reactor design, analysis and licensing. The knowledge base will serve as an important resource for technical exchange and collaboration that will enable credible and reliable computational models and simulations for application to nuclear power. NE-KAMS will serve as a valuable resource for the nuclear industry, academia, the national laboratories, the U.S. Nuclear Regulatory Commission (NRC) and

  8. Design of 2.5 GHz broad bandwidth microwave bandpass filter at operating frequency of 10 GHz using HFSS

    Science.gov (United States)

    Jasim, S. E.; Jusoh, M. A.; Mahmud, S. N. S.; Zamani, A. H.

    2018-04-01

    Development of low losses, small size and broad bandwidth microwave bandpass filter operating at higher frequencies is an active area of research. This paper presents a new route used to design and simulate microwave bandpass filter using finite element modelling and realized broad bandwidth, low losses, small dimension microwave bandpass filter operating at 10 GHz frequency using return loss method. The filter circuit has been carried out using Computer Aid Design (CAD), Ansoft HFSS software and designed with four parallel couple line model and small dimension (10 × 10 mm2) using LaAlO3 substrate. The response of the microwave filter circuit showed high return loss -50 dB at operating frequency at 10.4 GHz and broad bandwidth of 2.5 GHz from 9.5 to 12 GHz. The results indicate the filter design and simulation using HFSS is reliable and have the opportunity to transfer from lab potential experiments to the industry.

  9. 45-GHz and 60-GHz 90 nm CMOS power amplifiers with a fully symmetrical 8-way transformer power combiner

    Institute of Scientific and Technical Information of China (English)

    Zhengdong JIANG; Kaizhe GUO; Peng HUANG; Yiming FAN; Chenxi ZHAO; Yongling BAN; Jun LIU; Kai KANG

    2017-01-01

    In this paper,45 GHz and 60 GHz power amplifiers (PAs) with high output power have been successfully designed by using 90 nm CMOS process.The 45 GHz (60 GHz) PA consists of two (four) differential stages.The sizes of transistors have been designed in an appropriate way so as to trade-off gain,efficiency and stability.Due to limited supply voltage and low breakdown voltage of CMOS MOSFET compared with the traditional Ⅲ-Ⅴ technologies,the technique of power combining has been applied to achieve a high output power.In particular,a novel 8-way distributed active transformer power combiner has been proposed for realizing such mm-wave PA.The proposed transformer combiner with a fully symmetrical layout can improve its input impedance balance at mm-wave frequency regime significantly.Taking its advantages of this novel transformer based power combiner,our realized 45 GHz (60 GHz) mm-wave PA has achieved the gain of 20.3 dB (16.8 dB),the maximum PAE of 14.5% (13.4%) and the saturated output power of 21 dBm (21 dBm) with the 1.2 V supply voltage.

  10. 77 FR 48097 - Operation of Radar Systems in the 76-77 GHz Band

    Science.gov (United States)

    2012-08-13

    ... modify the emission limits for vehicular radar systems operating within the 76-77 GHz band. Specifically.... 15.253 of the rules for vehicular radar systems operating in the 76-77 GHz band. Vehicular radars can... sensors operating in the 76-77 GHz band, the spectrum shall be investigated up to 231 GHz. (f) Fundamental...

  11. 47 CFR 25.136 - Licensing provisions for user transceivers in the 1.6/2.4 GHz, 1.5/1.6 GHz, and 2 GHz Mobile...

    Science.gov (United States)

    2010-10-01

    ...) Incorporation of ancillary terrestrial component base station into an L-band mobile-satellite service system... ancillary terrestrial component (ATC) base stations as defined in § 25.201 at its own risk and subject to... Applications and Licenses Earth Stations § 25.136 Licensing provisions for user transceivers in the 1.6/2.4 GHz...

  12. Development and validation of an improved LC-MS/MS method for the quantification of desloratadine and its metabolite in human plasma using deutrated desloratadine as internal standard

    Directory of Open Access Journals (Sweden)

    M Saquib Hasnain

    2013-01-01

    Full Text Available Purpose: For the determination of desloratadine (DES and 3-OH desloratadine (3-OHD in human plasma using deutrated desloratadine (DESD5 as internal standard (IS, a novel stability indicating liquid chromatography-tandem mass spectrometric method was developed and validated to support the clinical advancement. Materials and Methods: The solid-phase extraction method used for sample preparation and calibration range was 100-11,000 pg/ml, for which a quadratic regression (1/x 2 was best fitted. The blank plasma was screened and observed free from any endogenous interference. Results: The accuracy (% nominal at low limit of quantification LLOQ level for DES and 3-OHD was 100.4% and 99.9% whereas precision (%CV was 4.6 and 5.1%. They (DES and 3-OHD were stable in human plasma after five freeze-thaw cycles, at room temperature for 23.8 hour, bench top stability for 6.4 hour. Conclusion: This method fulfills all the regulatory requirements for selectivity, sensitivity, precision, accuracy, stability, goodness of fit, and ruggedness of the method for the determination of DES and 3-OHD in human plasma.

  13. Validation for 2D/3D registration II: The comparison of intensity- and gradient-based merit functions using a new gold standard data set

    International Nuclear Information System (INIS)

    Gendrin, Christelle; Markelj, Primoz; Pawiro, Supriyanto Ardjo; Spoerk, Jakob; Bloch, Christoph; Weber, Christoph; Figl, Michael; Bergmann, Helmar; Birkfellner, Wolfgang; Likar, Bostjan; Pernus, Franjo

    2011-01-01

    Purpose: A new gold standard data set for validation of 2D/3D registration based on a porcine cadaver head with attached fiducial markers was presented in the first part of this article. The advantage of this new phantom is the large amount of soft tissue, which simulates realistic conditions for registration. This article tests the performance of intensity- and gradient-based algorithms for 2D/3D registration using the new phantom data set. Methods: Intensity-based methods with four merit functions, namely, cross correlation, rank correlation, correlation ratio, and mutual information (MI), and two gradient-based algorithms, the backprojection gradient-based (BGB) registration method and the reconstruction gradient-based (RGB) registration method, were compared. Four volumes consisting of CBCT with two fields of view, 64 slice multidetector CT, and magnetic resonance-T1 weighted images were registered to a pair of kV x-ray images and a pair of MV images. A standardized evaluation methodology was employed. Targets were evenly spread over the volumes and 250 starting positions of the 3D volumes with initial displacements of up to 25 mm from the gold standard position were calculated. After the registration, the displacement from the gold standard was retrieved and the root mean square (RMS), mean, and standard deviation mean target registration errors (mTREs) over 250 registrations were derived. Additionally, the following merit properties were computed: Accuracy, capture range, number of minima, risk of nonconvergence, and distinctiveness of optimum for better comparison of the robustness of each merit. Results: Among the merit functions used for the intensity-based method, MI reached the best accuracy with an RMS mTRE down to 1.30 mm. Furthermore, it was the only merit function that could accurately register the CT to the kV x rays with the presence of tissue deformation. As for the gradient-based methods, BGB and RGB methods achieved subvoxel accuracy (RMS m

  14. Arbitrary waveform modulated pulse EPR at 200 GHz

    Science.gov (United States)

    Kaminker, Ilia; Barnes, Ryan; Han, Songi

    2017-06-01

    We report here on the implementation of arbitrary waveform generation (AWG) capabilities at ∼200 GHz into an Electron Paramagnetic Resonance (EPR) and Dynamic Nuclear Polarization (DNP) instrument platform operating at 7 T. This is achieved with the integration of a 1 GHz, 2 channel, digital to analog converter (DAC) board that enables the generation of coherent arbitrary waveforms at Ku-band frequencies with 1 ns resolution into an existing architecture of a solid state amplifier multiplier chain (AMC). This allows for the generation of arbitrary phase- and amplitude-modulated waveforms at 200 GHz with >150 mW power. We find that the non-linearity of the AMC poses significant difficulties in generating amplitude-modulated pulses at 200 GHz. We demonstrate that in the power-limited regime of ω1 10 MHz) spin manipulation in incoherent (inversion), as well as coherent (echo formation) experiments. Highlights include the improvement by one order of magnitude in inversion bandwidth compared to that of conventional rectangular pulses, as well as a factor of two in improvement in the refocused echo intensity at 200 GHz.

  15. Developmental validation of the PowerPlex(®) ESI 16 and PowerPlex(®) ESI 17 Systems: STR multiplexes for the new European standard.

    Science.gov (United States)

    Tucker, Valerie C; Hopwood, Andrew J; Sprecher, Cynthia J; McLaren, Robert S; Rabbach, Dawn R; Ensenberger, Martin G; Thompson, Jonelle M; Storts, Douglas R

    2011-11-01

    In response to the ENFSI and EDNAP groups' call for new STR multiplexes for Europe, Promega(®) developed a suite of four new DNA profiling kits. This paper describes the developmental validation study performed on the PowerPlex(®) ESI 16 (European Standard Investigator 16) and the PowerPlex(®) ESI 17 Systems. The PowerPlex(®) ESI 16 System combines the 11 loci compatible with the UK National DNA Database(®), contained within the AmpFlSTR(®) SGM Plus(®) PCR Amplification Kit, with five additional loci: D2S441, D10S1248, D22S1045, D1S1656 and D12S391. The multiplex was designed to reduce the amplicon size of the loci found in the AmpFlSTR(®) SGM Plus(®) kit. This design facilitates increased robustness and amplification success for the loci used in the national DNA databases created in many countries, when analyzing degraded DNA samples. The PowerPlex(®) ESI 17 System amplifies the same loci as the PowerPlex(®) ESI 16 System, but with the addition of a primer pair for the SE33 locus. Tests were designed to address the developmental validation guidelines issued by the Scientific Working Group on DNA Analysis Methods (SWGDAM), and those of the DNA Advisory Board (DAB). Samples processed include DNA mixtures, PCR reactions spiked with inhibitors, a sensitivity series, and 306 United Kingdom donor samples to determine concordance with data generated with the AmpFlSTR(®) SGM Plus(®) kit. Allele frequencies from 242 white Caucasian samples collected in the United Kingdom are also presented. The PowerPlex(®) ESI 16 and ESI 17 Systems are robust and sensitive tools, suitable for the analysis of forensic DNA samples. Full profiles were routinely observed with 62.5pg of a fully heterozygous single source DNA template. This high level of sensitivity was found to impact on mixture analyses, where 54-86% of unique minor contributor alleles were routinely observed in a 1:19 mixture ratio. Improved sensitivity combined with the robustness afforded by smaller amplicons

  16. Validation of an indirect ELISA to detect antibodies against BoHV-1 in bovine and guinea-pig serum samples using ISO/IEC 17025 standards.

    Science.gov (United States)

    Parreño, Viviana; Romera, S Alejandra; Makek, Lucia; Rodriguez, Daniela; Malacari, Darío; Maidana, Silvina; Compaired, Diego; Combessies, Gustavo; Vena, María Marta; Garaicoechea, Lorena; Wigdorovitz, Andrés; Marangunich, Laura; Fernandez, Fernando

    2010-10-01

    Two ELISAs to quantify antibodies to BoHV-1 in the sera of cattle and immunized guinea pigs were developed and validated using ISO/IEC 17025 standards. The cut-off value of the assay was established at 20% positivity of a high positive control for screening of cattle. Using this threshold, the assay properly classified the OIE bovine reference sera EU1, EU2 and EU3. For vaccine potency testing, a cut-off of 40% was selected for both species. The reliability of the assays, given by their diagnostic sensitivity and specificity, using the threshold of 40% was 89.7% and 100%, respectively, for bovines and 94.9% and 100% for guinea pigs, respectively. There was almost perfect agreement between the ELISA and virus neutralization results. In addition, after vaccination, there was a good correlation between the neutralizing and ELISA antibody titers of the serum from the same bovine or guinea pig, sampled at 60 and 30 days post-vaccination, respectively (R(bovine)=0.88, R(guinea pig)=0.92; p<0.0001). A similar correlation was observed when analyzing the mean antibody titers of groups of vaccinated animals (R(bovine)=0.95 and R(guinea pig)=0.97; p<0.0001), indicating the relevance of the ELISAs for batch to batch vaccine potency testing in the target species and in the laboratory animal model. The intermediate precision of the assays expressed as the relative coefficient of variation (CV) of the positive control assayed over a 3-year period in the same laboratory was 22.2% for bovines and 23.1% for guinea pigs. The reproducibility of both techniques obtained in inter-laboratory assays was CV=12.4% for bovines and CV approximately 0 for guinea pigs, which met the requirements of the OIE (CV<30%). The validated ELISAs represent important methods for vaccine potency testing and for controlling BoHV-1 infections. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  17. Status of the development of the EU 170 GHz/1 MW/CW gyrotron

    Energy Technology Data Exchange (ETDEWEB)

    Pagonakis, Ioannis Gr., E-mail: ioannis.pagonakis@kit.edu [Karlsruhe Institute of Technology (KIT), Karlsruhe (Germany); Albajar, Ferran [The European Joint Undertaking for ITER and The Development of Fusion Energy, Barcelona (Spain); Alberti, Stefano [École Polytechnique Fédérale de Lausanne, Centre de Recherches en Physique des Plasmas (CRPP), Lausanne (Switzerland); Avramidis, Konstantinos [Karlsruhe Institute of Technology (KIT), Karlsruhe (Germany); Bonicelli, Tullio [The European Joint Undertaking for ITER and The Development of Fusion Energy, Barcelona (Spain); Braunmueller, Falk [École Polytechnique Fédérale de Lausanne, Centre de Recherches en Physique des Plasmas (CRPP), Lausanne (Switzerland); Bruschi, Alex [Plasma Physics Institute, National Research Council of Italy, Milano (Italy); Chelis, Ioannis [School of Electrical and Computer Engineering, National Technical University of Athens (Greece); Cismondi, Fabio [The European Joint Undertaking for ITER and The Development of Fusion Energy, Barcelona (Spain); Gantenbein, Gerd [Karlsruhe Institute of Technology (KIT), Karlsruhe (Germany); Hermann, Virgile [Thales Electron Devices (TED), Vélizy-Villacoublay (France); Hesch, Klaus [Karlsruhe Institute of Technology (KIT), Karlsruhe (Germany); Hogge, Jean-Philippe [École Polytechnique Fédérale de Lausanne, Centre de Recherches en Physique des Plasmas (CRPP), Lausanne (Switzerland); Jelonnek, John; Jin, Jianbo; Illy, Stefan [Karlsruhe Institute of Technology (KIT), Karlsruhe (Germany); Ioannidis, Zisis C. [Faculty of Physics, National and Kapodistrian University of Athens (Greece); Kobarg, Thorsten [Karlsruhe Institute of Technology (KIT), Karlsruhe (Germany); and others

    2015-10-15

    The progress in the development of the European 170 GHz, 1 MW/CW gyrotron for electron cyclotron heating & current drive (ECH&CD) on ITER is reported. A continuous wave (CW) prototype is being manufactured by Thales Electron Devices (TED), France, while a short-pulse (SP) prototype gyrotron is in parallel under manufacture at Karlsruhe Institute of Technology (KIT), with the purpose of validating the design of the CW industrial prototype components. The fabrication of most of the sub-assemblies of the SP prototype has been completed. In a first step, an existing magnetron injection gun (MIG) available at KIT was used. Despite this non-ideal configuration, the experiments provided a validation of the design, substantiated by an excellent agreement with numerical simulations. The tube, operated without a depressed collector, is able to produce more than 1 MW of output power with efficiency in excess of 30%, as expected, and compatible with the ITER requirements.

  18. Experimental measurements on a 100 GHz frequency tunable quasioptical gyrotron

    International Nuclear Information System (INIS)

    Alberti, S.; Tran, M.Q.; Hogge, J.P.; Tran, T.M.; Bondeson, A.; Muggli, P.; Perrenoud, A.; Joedicke, B.; Mathews, H.G.

    1990-01-01

    Experiments on a 100 GHz quasioptical (QO) gyrotron operating at the fundamental (ω=Ω ce ) are described. Powers larger than 90 kW at an efficiency of about 12% were achieved. Depending on the electron beam parameters, the frequency spectrum of the output can be either single moded or multimoded. One of the main advantages of the QO gyrotron over the conventional gyrotron is its continuous frequency tunability. Various techniques to tune the output frequency have been tested, such as changing the mirror separation, the beam voltage, or the main magnetic field. Within the limitations of the present setup, 5% tunability was achieved. The QO gyrotron designed for operation at the fundamental frequency exhibits simultaneous emission at 100 GHz (fundamental) and 200 GHz (second harmonic). For a beam current of 4 A, 20% of the total rf power is emitted at the second harmonic

  19. Controlled and secure direct communication using GHZ state and teleportation

    International Nuclear Information System (INIS)

    Gao, T.

    2004-01-01

    A theoretical scheme for controlled and secure direct communication is proposed. The communication is based on GHZ state and controlled quantum teleportation. After insuring the security of the quantum channel (a set of qubits in the GHZ state), alice encodes the secret message directly on a sequence of particle states in the GHZ state and transmits them to Bob, supervised by Charlie using controlled quantum teleportation. Bob can read out the encoded messages directly by the measurement on his qubits. In this scheme, the controlled quantum teleportation transmits alice's message without revealing any information to a potential eavesdropper. Because there is not a transmission of the qubit carrying the secret messages between Alice and Bob in the public channel, it is completely secure for controlled and direct secret communication if a perfect quantum channel is used. The feature of this scheme is that the communication between two sides depends on the agreement of a third side. (orig.)

  20. 125-GHz Microwave Signal Generation Employing an Integrated Pulse Shaper

    DEFF Research Database (Denmark)

    Liao, Shasha; Ding, Yunhong; Dong, Jianji

    2017-01-01

    We propose and experimentally demonstrate an on-chip pulse shaper for 125-GHz microwave waveform generation. The pulse shaper is implemented based on a silicon-on-insulator (SOI) platform that has a structure with eight-tap finite impulse response (FIR) and there is an amplitude modulator on each...... of the generated microwave waveforms is larger than 100 GHz, and it has wide bandwidth when changing the time delay of the adjacent taps and compactness, capability for integration with electronics and small power consumption are also its merits.......We propose and experimentally demonstrate an on-chip pulse shaper for 125-GHz microwave waveform generation. The pulse shaper is implemented based on a silicon-on-insulator (SOI) platform that has a structure with eight-tap finite impulse response (FIR) and there is an amplitude modulator on each...

  1. A CMOS frequency generation module for 60-GHz applications

    International Nuclear Information System (INIS)

    Zhou Chunyuan; Zhang Lei; Wang Hongrui; Qian He

    2012-01-01

    A frequency generation module for 60-GHz transceivers and phased array systems is presented in this paper. It is composed of a divide-by-2 current mode logic divider (CML) and a doubler in push-push configuration. Benefiting from the CML structure and push-push configuration, the proposed frequency generation module has a wide operating frequency range to cover process, voltage, and temperature variation. It is implemented in a 90-nm CMOS process, and occupies a chip area of 0.64 × 0.65 mm 2 including pads. The measurement results show that the designed frequency generation module functions properly with input frequency over 15 GHz to 25 GHz. The whole chip dissipates 12.1 mW from a 1.2-V supply excluding the output buffers. (semiconductor integrated circuits)

  2. Development and validation of an individual dietary index based on the British Food Standard Agency nutrient profiling system in a French context.

    Science.gov (United States)

    Julia, Chantal; Touvier, Mathilde; Méjean, Caroline; Ducrot, Pauline; Péneau, Sandrine; Hercberg, Serge; Kesse-Guyot, Emmanuelle

    2014-12-01

    Nutrient profiling systems could be useful public health tools as a basis for front-of-package nutrition labeling, advertising regulations, or food taxes. However, their ability beyond characterization of foods to adequately characterize individual diets necessitates further investigation. The objectives of this study were 1) to calculate a score at the individual level based on the British Food Standard Agency (FSA) food-level nutrient profiling system of each food consumed, and 2) to evaluate the validity of the resulting diet-quality score against food group consumption, nutrient intake, and sociodemographic and lifestyle variables. A representative sample of the French population was selected from the NutriNet-Santé Study (n = 4225). Dietary data were collected through repeated 24-h dietary records. Sociodemographic and lifestyle data were self-reported. All foods consumed were characterized by their FSA nutrient profile, and the energy intake from each food consumed was used to compute FSA-derived aggregated scores at the individual level. A score of adherence to French nutritional recommendations [Programme National Nutrition Santé guideline score (PNNS-GS)] was computed as a comparison diet-quality score. Associations between food consumption, nutritional indicators, lifestyle and sociodemographic variables, and quartiles of aggregated scores were investigated using ANOVAs and linear regression models. Participants with more favorable scores consumed higher amounts of fruits [difference Δ = 156 g/d between quartile 1 (less favorable) and quartile 4 (most favorable), P foods (Δ = -72 g/d, P French context. The NutriNet-Santé Study was registered in the European Clinical Trials Database (EudraCT) as 2013-000929-31. © 2014 American Society for Nutrition.

  3. Microwave sintering of zirconia toughened alumina at 28GHz

    International Nuclear Information System (INIS)

    Samandi, M.; Ji, H.; Miyake, S.

    1998-01-01

    Microwave radiation from a 10 kW, CW gyrotron operating at 28 GHz was employed to sinter 10% zirconia toughened alumina (ZTA) ceramic samples. It has been established that the use of millimetre wave radiation circumvents the difficulties encountered during the sintering of ceramics, i e. formation of hot spot, by radiation at industrially permissible frequency of 2.45GHz. Further, careful density measurement and microstructural characterisation of mm- wave and conventionally sintered samples by XRD, SEM and TEM has unequivocally demonstrated the effectiveness of mm-wave radiation for obtaining high density ceramics at lower sintering temperatures. Copyright (1998) Australasian Ceramic Society

  4. 24 GHz cmWave Radio Propagation Through Vegetation

    DEFF Research Database (Denmark)

    Rodriguez, Ignacio; Abreu, Renato Barbosa; Portela Lopes de Almeida, Erika

    2016-01-01

    This paper presents a measurement-based analysis of cm-wave radio propagation through vegetation at 24 GHz. A set of dedicated directional measurements were performed with horn antennas located close to street level inside a densely-vegetated area illuminated from above. The full azimuth was exam......This paper presents a measurement-based analysis of cm-wave radio propagation through vegetation at 24 GHz. A set of dedicated directional measurements were performed with horn antennas located close to street level inside a densely-vegetated area illuminated from above. The full azimuth...

  5. Characterization of a 300-GHz Transmission System for Digital Communications

    Science.gov (United States)

    Hudlička, Martin; Salhi, Mohammed; Kleine-Ostmann, Thomas; Schrader, Thorsten

    2017-08-01

    The paper presents the characterization of a 300-GHz transmission system for modern digital communications. The quality of the modulated signal at the output of the system (error vector magnitude, EVM) is measured using a vector signal analyzer. A method using a digital real-time oscilloscope and consecutive mathematical processing in a computer is shown for analysis of signals with bandwidths exceeding that of state-of-the-art vector signal analyzers. The uncertainty of EVM measured using the real-time oscilloscope is open to analysis. Behaviour of the 300-GHz transmission system is studied with respect to various modulation schemes and different signal symbol rates.

  6. Ultra-wideband and 60 GHz communications for biomedical applications

    CERN Document Server

    Yuce, Mehmet R

    2013-01-01

    This book investigates the design of devices, systems, and circuits for medical applications using the two recently established frequency bands: ultra-wideband (3.1-10.6 GHz) and 60 GHz ISM band. These two bands provide the largest bandwidths available for communication technologies and present many attractive opportunities for medical applications. The applications of these bands in healthcare are wireless body area network (WBAN), medical imaging, biomedical sensing, wearable and implantable devices, fast medical device connectivity, video data transmission, and vital signs monitoring. The r

  7. Molecular astronomy using heterodyne detection at 691 GHz

    International Nuclear Information System (INIS)

    Fetterman, H.R.; Buhl, D.

    1984-01-01

    Observations of the CO J 6 - 5 transition at 691 GHz in new interstellar and planetary sources have been made. The heterodyne receiver uses an optically pumped laser local oscillator and a quasi-optical Schottky diode mixer, with measured noise temperatures consistently under 4000 K (double sideband). Continued improvements in system performance and antenna coupling have made possible the mapping of 691 GHz emission from W3, and the detection of CO J 5 - 6 absorption in the atmosphere of Venus. A detailed description of the instrumentation and recent observational data are provided. 14 references

  8. 143 GHz BRIGHTNESS MEASUREMENTS OF URANUS, NEPTUNE, AND OTHER SECONDARY CALIBRATORS WITH BOLOCAM BETWEEN 2003 AND 2010

    International Nuclear Information System (INIS)

    Sayers, J.; Czakon, N. G.; Golwala, S. R.

    2012-01-01

    Bolocam began collecting science data in 2003 as the long-wavelength imaging camera at the Caltech Submillimeter Observatory. The planets, along with a handful of secondary calibrators, have been used to determine the flux calibration for all of the data collected with Bolocam. Uranus and Neptune stand out as the only two planets that are bright enough to be seen with high signal-to-noise in short integrations without saturating the standard Bolocam readout electronics. By analyzing all of the 143 GHz observations made with Bolocam between 2003 and 2010, we find that the brightness ratio of Uranus to Neptune is 1.027 ± 0.006, with no evidence for any variations over that period. Including previously published results at ≅ 150 GHz, we find a brightness ratio of 1.029 ± 0.006 with no evidence for time variability over the period 1983-2010. Additionally, we find no evidence for time variability in the brightness ratio of either Uranus or Neptune to the ultracompact H II region G34.3 or the protostellar source NGC 2071IR. Using recently published Wilkinson Microwave Anisotropy Probe results we constrain the absolute 143 GHz brightness of both Uranus and Neptune to ≅ 3%. Finally, we present ≅ 3% absolute 143 GHz peak flux density values for the ultracompact H II regions G34.3 and K3-50A and the protostellar source NGC 2071IR.

  9. RF-MEMS for future mobile applications: experimental verification of a reconfigurable 8-bit power attenuator up to 110 GHz

    International Nuclear Information System (INIS)

    Iannacci, J; Tschoban, C

    2017-01-01

    RF-MEMS technology is proposed as a key enabling solution for realising the high-performance and highly reconfigurable passive components that future communication standards will demand. In this work, we present, test and discuss a novel design concept for an 8-bit reconfigurable power attenuator, manufactured using the RF-MEMS technology available at the CMM-FBK, in Italy. The device features electrostatically controlled MEMS ohmic switches in order to select/deselect the resistive loads (both in series and shunt configuration) that attenuate the RF signal, and comprises eight cascaded stages (i.e. 8-bit), thus implementing 256 different network configurations. The fabricated samples are measured (S-parameters) from 10 MHz to 110 GHz in a wide range of different configurations, and modelled/simulated with Ansys HFSS. The device exhibits attenuation levels (S21) in the range from  −10 dB to  −60 dB, up to 110 GHz. In particular, S21 shows flatness from 15 dB down to 3–5 dB and from 10 MHz to 50 GHz, as well as fewer linear traces up to 110 GHz. A comprehensive discussion is developed regarding the voltage standing wave ratio, which is employed as a quality indicator for the attenuation levels. The margins of improvement at design level which are needed to overcome the limitations of the presented RF-MEMS device are also discussed. (paper)

  10. Pseudo Open Drain IO Standards Based Energy Efficient Solar Charge Sensor Design on 20nm FPGA

    DEFF Research Database (Denmark)

    Kalia, K; Pandey, B; Nanda, K

    2015-01-01

    solar charge inverter. We also observed maximum total power reduction in LVCMOS18 (Artix-7 FPGA) as compared to other I/O standards at 10 GHz. Also there is maximum total power reduction in POD12 (Ultra Scale Kintex) as compared to other I/O standards at 2 GHz. There is also a significant change...

  11. Wideband Circularly Polarized Printed Ring Slot Antenna for 5 GHz – 6 GHz

    Science.gov (United States)

    Nasrun Osman, Mohamed; Rahim, Mohamad Helmi A.; Jusoh, Muzammil; Sabapathy, Thennarasan; Rahim, Mohamad Kamal A.; Norlyana Azemi, Saidatul

    2018-03-01

    This paper presents the design of circularly polarized printed slot antenna operating at 5 – 6 GHz. The proposed antenna consists of L-shaped feedline on the top of structure and circular ring slot positioned at the ground plane underneath the substrate as a radiator. A radial and narrow slot in the ground plane provides coupling between the L-shaped feedline and circular ring slot. The circular polarization is realized by implementing the slits perturbation located diagonally to perturb the current flow on the slot structure. The antenna prototype is fabricated on FR4 substrate. The simulated and measured results are compared and analyzed to demonstrate the performance of the antenna. Good measured of simulated results are obtained at the targeted operating frequency. The simulated -10dB reflection coefficient bandwidths and axial ratio are 750 MHz and 165 MHz, respectively. The investigation on the affect of the important parameters towards the reflection coefficient and axial are also presented. The proposed antenna is highly potential to be used for wireless local area network (WLAN) and wireless power transfer (WPT).

  12. A dual-band near-field focused reflectarray antenna for RFID applications at 0.9 and 2.4 GHz

    Science.gov (United States)

    Chou, Hsi-Tseng; Hsueh, Pai-Han; Hung, Tso-Ming; Kuo, Li-Ruei; Chou, Hsi-Hsir

    2011-12-01

    This paper presents a dual-band reflectarray antenna which operates at 0.915 and 2.4 GHz to radiate electromagnetic fields focused in the near-zone of array aperture. The design uses two stacked feed antennas operated at 0.915 and 2.4 GHz, respectively, so that the currently available RFID systems in the market can be simultaneously used in an independent fashion. Numerical investigations on the radiation characteristics of this reflectarray, as well as an experimental validation, are presented to demonstrate its feasibility.

  13. Measurements by a Vector Network Analyzer at 325 to 508 GHz

    Science.gov (United States)

    Fung, King Man; Samoska, Lorene; Chattopadhyay, Goutam; Gaier, Todd; Kangaslahti, Pekka; Pukala, David; Lau, Yuenie; Oleson, Charles; Denning, Anthony

    2008-01-01

    Recent experiments were performed in which return loss and insertion loss of waveguide test assemblies in the frequency range from 325 to 508 GHz were measured by use of a swept-frequency two-port vector network analyzer (VNA) test set. The experiments were part of a continuing effort to develop means of characterizing passive and active electronic components and systems operating at ever increasing frequencies. The waveguide test assemblies comprised WR-2.2 end sections collinear with WR-3.3 middle sections. The test set, assembled from commercially available components, included a 50-GHz VNA scattering- parameter test set and external signal synthesizers, augmented with recently developed frequency extenders, and further augmented with attenuators and amplifiers as needed to adjust radiofrequency and intermediate-frequency power levels between the aforementioned components. The tests included line-reflect-line calibration procedures, using WR-2.2 waveguide shims as the "line" standards and waveguide flange short circuits as the "reflect" standards. Calibrated dynamic ranges somewhat greater than about 20 dB for return loss and 35 dB for insertion loss were achieved. The measurement data of the test assemblies were found to substantially agree with results of computational simulations.

  14. Variability of GPS Radio Sources at 5 GHz

    Indian Academy of Sciences (India)

    GPS) radio sources at 5 GHz and find that about one-third of them show considerable Inter-Month Variability (IMV), and these IMV phenomena are likely to be caused by interstellar scintillation (ISS). Furthermore, we find that those showing IMV ...

  15. Laboratory Heterodyne Spectrometers Operating at 100 and 300 GHZ

    Science.gov (United States)

    Maßen, Jakob; Wehres, Nadine; Hermanns, Marius; Lewen, Frank; Heyne, Bettina; Endres, Christian; Graf, Urs; Honingh, Netty; Schlemmer, Stephan

    2017-06-01

    Two new laboratory heterodyne emission spectrometers are presented that are currently used for high-resolution rotational spectroscopy of complex organic molecules. The room temperature heterodyne receiver operating between 80-110 GHz, as well as the SIS heterodyne receiver operating between 270-370 GHz allow access to two very important frequency regimes, coinciding with Bands 3 and 7 of the ALMA (Atacama Large Millimeter Array) telescope. Taking advantage of recent progresses in the field of mm/submm technology, we build these two spectrometers using an XFFFTS (eXtended Fast Fourier Transform Spectrometer) for spectral acquisition. The instantaneous bandwidth is 2.5 GHz in a single sideband, spread over 32768 channels. Thus, the spectral resolution is about 76 kHz per channel and thus comparable to high resolution spectra from telescopes. Both receivers are operated in double sideband mode resulting in a total instantaneous bandwidth of 5 GHz. The system performances, in particular the noise temperatures and stabilities are presented. Proof-of-concept is demonstrated by showing spectra of methyl cyanide obtained with both spectrometers. While the transition frequencies for this molecule are very well known, intensities of those transitions can also be determined with high accuracy using our new instruments. This additional information shall be exploited in future measurements to improve spectral predictions for astronomical observations. Other future prospects concern the study of more complex organic species, such as ethyl cyanide. These aspects of the new instruments as well as limitations of the two distinct receivers will be discussed.

  16. Characterisation of propagation in 60 GHz radio channels (invited)

    NARCIS (Netherlands)

    Smulders, P.F.M.; Correia, L.M.

    1997-01-01

    Narrowband as well as wideband measurements have been performed in various indoor and outdoor environments in order to enable the development of reliable prediction models for 60 GHz radio channels. In addition, results of deterministic modelling on the basis of geometric ray-tracing have been

  17. 2.4GHz energy harvesting for wireless sensor network

    NARCIS (Netherlands)

    Gao, H.; Baltus, P.G.M.; Mahmoudi, R.; Roermund, van A.H.M.

    2011-01-01

    This paper presents the analysis of the performance of charge pump, and the design strategy and efficiency optimization of 2.4GHz micro-power charge pump using 65nm CMOS technology. The model of the charge pump takes account of the threshold voltage variation, bulk modulation, and the major

  18. Sideband Separating Mixer for 600-720 GHz

    NARCIS (Netherlands)

    Khudchenko, Andrey; Hesper, Ronald; Barychev, Andrey; Gerlofma, Gerrit; Mena, Patricio; Zijlstra, Tony; Klapwijk, Teun; Spaans, Marco; Kooi, Jacob W.; Zhang, C; Zhang, XC; Siegel, PH; He, L; Shi, SC

    2010-01-01

    The ALMA Band 9 receiver cartridge (600-720 GHz) based on Dual Sideband (DSB) superconductor-insulator-superconductor (SIS) mixer is currently in full production. In the case of spectral line observations, the integration time to reach a certain signal-to-noise level can be reduced by about a factor

  19. Rain-induced bistatic scattering at 60 GHz

    NARCIS (Netherlands)

    Zanden, van der H.T.; Watson, R.J.; Herben, M.H.A.J.

    2007-01-01

    This paper presents the results of a study into the modeling and prediction of rain-induced bistatic scattering at 60 GHz. The bistatic radar equation together withMie theory is applied as the basis for calculating the scattering. Together with the attenuation induced by the medium before and after

  20. Logo Antenna for 5.8 GHz Wireless Communications (invited)

    DEFF Research Database (Denmark)

    Jørgensen, Kasper Lüthje; Jakobsen, Kaj Bjarne

    2016-01-01

    A logo antenna for the 5.8 GHz ISM band is presented. The idea behind the logo antenna is to use the company or university logo as part of the antenna. When disguised as a logo, it may be more acceptable to place the antenna at optimal locations to obtain good coverage. In the present work...

  1. Logo Antenna for 5.8 GHz Wireless Communications

    DEFF Research Database (Denmark)

    Jørgensen, Kasper Lüthje; Jakobsen, Kaj Bjarne

    2016-01-01

    A logo antenna for the 5.8 GHz ISM band is presented. The idea behind the logo antenna is to use the company or university logo as part of the antenna. When disguised as a logo, it may be more acceptable to place the antenna at optimal locations to obtain good coverage. In the present work...

  2. Lightning and 85-GHz MCSs in the Global Tropics

    Science.gov (United States)

    Toracinta, E. Richard; Zipser, E. J.

    1999-01-01

    Numerous observations of tropical convection show that tropical continental mesoscale convective systems (MCSs) are much more prolific lightning producers than their oceanic counterparts. Satellite-based climatologies using 85-GHz passive microwave ice-scattering signatures from the Special Sensor Microwave/Imager (SSM/I) indicate that MCSs of various size and intensity are found throughout the global tropics. In contrast, global lightning distributions show a strong land bias with an order of magnitude difference between land and ocean lightning. This is somewhat puzzling, since 85-GHz ice-scattering and the charge separation processes that lead to lightning are both thought to depend upon the existence of large graupel particles. The fact that low 85-GHz brightness temperatures are observed in tropical oceanic MCSs containing virtually no lightning leads to the postulate that tropical oceanic and tropical continental MCSs have fundamentally different hydrometeor profiles through the mixed phase region of the cloud (0 C Lightning Imaging Sensor (LIS), and the first space-borne radar, facilitates high-resolution case studies of MCS structure throughout the global tropics. An important precursor, however, is to better understand the distribution of MCSs and lightning in the tropics. With that objective in mind, this research undertakes a systematic comparison of 85-GHz-defined MCSs and lightning over the global tropics for a full year, as an initial step toward quantifying differences between land and ocean convective systems.

  3. A 60-GHz rectenna for monolithic wireless sensor tags

    NARCIS (Netherlands)

    Gao, H.; Johannsen, U.; Matters - Kammerer, M.; Milosevic, D.; Smolders, A.B.; Roermund, van A.H.M.; Baltus, P.G.M.

    2013-01-01

    This paper presents the design of a 60-GHz rectenna with an on-chip antenna and rectifier in 65nm CMOS technology. The rectenna is often the bottleneck in realizing a fully-integrated monolithic wireless sensor tag. In this paper, problems of the mm-wave rectifier are discussed, and the

  4. Wearable Shell Antenna for 2.4 GHz Hearing Instruments

    DEFF Research Database (Denmark)

    Ruaro, Andrea; Thaysen, Jesper; Jakobsen, Kaj Bjarne

    2016-01-01

    A novel concept for an electrically-small on-body antenna targeted for 2.4 GHz ISM band custom in-the-ear (ITE) hearing instrument (HI) applications is introduced. The antenna is based upon a cavity-backed design in order to take advantage of the maximum volume available in the ear while providin...

  5. Design of the 1-Mw, 200-Ghz, Fom Fusion Fem

    NARCIS (Netherlands)

    Urbanus, W. H.; Best, R. W. B.; Bongers, W. A.; Vaningen, A. M.; Manintveld, P.; Sterk, A. B.; Verhoeven, A. G. A.; van der Wiel, M. J.; Caplan, M.; Bratman, V. L.; Denisov, G. G.; Varfolomeev, A. A.; Khlebnikov, A. S.

    1993-01-01

    The FOM Institute for Plasma Physics has obtained funding for the development of a 1 MW, long pulse, 140-250 GHz free-electron maser. The engineering design is presently being performed in an international collaboration. In this paper the main components of the free-electron maser, the electron beam

  6. A 62GHz inductor-peaked rectifier with 7% efficiency

    NARCIS (Netherlands)

    Gao, H.; Matters - Kammerer, M.; Milosevic, D.; Roermund, van A.H.M.; Baltus, P.G.M.

    2013-01-01

    This paper presents the first 62 GHz fully onchip RF-DC rectifier in 65nm CMOS technology. The rectifier is the bottleneck in realizing on-chip wireless power receivers. In this paper, efficiency problems of the mm-wave rectifier are discussed and the inductor-peaked rectifier structure is proposed

  7. 47 CFR 15.251 - Operation within the bands 2.9-3.26 GHz, 3.267-3.332 GHz, 3.339-3.3458 GHz, and 3.358-3.6 GHz.

    Science.gov (United States)

    2010-10-01

    ... exceed 3000 microvolts/meter/MHz at 3 meters in any direction. Further, an AVIS, when in its operating position, shall not produce a field strength greater than 400 microvolts/meter/MHz at 3 meters in any... maximum of 100 microvolts/meter/MHz at 3 meters, measured from 30 MHz to 20 GHz for the complete system...

  8. Elements of a realistic 17 GHz FEL/TBA design

    International Nuclear Information System (INIS)

    Hopkins, D.B.; Halbach, K.; Hoyer, E.H.; Sessler, A.M.; Sternbach, E.J.

    1989-01-01

    Recently, renewed interest in an FEL version of a two-beam accelerator (TBA) has prompted a study of practical system and structure designs for achieving the specified physics goals. This paper presents elements of a realistic design for an FEL/TBA suitable for a 1 TeV, 17 GHz linear collider. 13 refs., 8 figs., 2 tabs

  9. Multi-gigabit wireless data transfer at 60 GHz

    International Nuclear Information System (INIS)

    Soltveit, H K; Schöning, A; Wiedner, D; Brenner, R

    2012-01-01

    In this paper we describe the status of the first prototype of the 60 GHz wireless Multi-gigabit data transfer topology currently under development at University of Heidelberg using IBM 130 nm SiGe HBT BiCMOS technology. The 60 GHz band is very suitable for high data rate and short distance applications. One application can be a wireless multi Gbps radial data transmission inside the ATLAS silicon strip detector, making a first level track trigger feasible. The wireless transceiver consists of a transmitter and a receiver. The transmitter includes an On-Off Keying (OOK) modulator, a Local Oscillator (LO), a Power Amplifier (PA) and a Band-pass Filter (BPF). The receiver part is composed of a Band-pass Filter (BPF), a Low Noise Amplifier (LNA), a double balanced down-convert Gilbert mixer, a Local Oscillator (LO), then a BPF to remove the mixer introduced noise, an Intermediate Amplifier (IF), an On-Off Keying demodulator and a limiting amplifier. The first prototype would be able to handle a data-rate of about 3.5 Gbps over a link distance of 1 m. The first simulations of the LNA show that a Noise figure (NF) of 5 dB, a power gain of 21 dB at 60 GHz with a 3 dB bandwidth of more than 20 GHz with a power consumption 11 mW are achieved. Simulations of the PA show an output referred compression point P1dB of 19.7 dB at 60 GHz.

  10. Do we all agree on how to measure work engagement? Factorial validity of Utrecht Work Engagement Scale as a standard measurement tool – A literature review

    OpenAIRE

    Konrad Kulikowski

    2017-01-01

    Work engagement as a predictor of health is an emerging concept in occupational science and the Utrecht Work Engagement Scale (UWES) is the most popular work engagement measurement tool. However, despite its popularity, the UWES is not free from controversy concerning its factorial validity. In this paper, 21 research studies on both UWES-9 and UWES-17 factorial validity within the confirmatory factor analysis (CFA) approach have been reviewed in order to answer the question as to which of th...

  11. Hot and cold body reference noise generators from 0 to 40 GHz

    Science.gov (United States)

    Hornbostel, D. H.

    1974-01-01

    This article describes the design, development, and analysis of exceptionally accurate radiometric noise generators from 0-40 GHz to serve as standard references. Size, weight, power, and reliability are optimized to meet the requirements of NASA air- and space-borne radiometers. The radiometric noise temperature of these noise generators is, unavoidably, calculated from measured values rather than measured directly. The absolute accuracy and stability are equal to or better than those of reliable standards available for comparison. A noise generator has been developed whose measurable properties (VSWR, line loss, thermometric temperatures) have been optimized in order to minimize the effects of the uncertainty in the calculated radiometric noise temperatures. Each measurable property is evaluated and analyzed to determine the effects of the uncertainty of the measured value. Unmeasurable properties (primarily temperature gradients) are analyzed, and reasonable precautions are designed into the noise generator to guarantee that the uncertainty of the value remains within tolerable limits.

  12. KEY COMPARISON: Final report on bilateral comparison CCEM.RF-K9.1: Thermal noise standards at 12.4 GHz, 13.5 GHz, 15 GHz and 17.5 GHz

    Science.gov (United States)

    Allal, Djamel

    2009-01-01

    A bilateral comparison subsequent to key comparison CCEM.RF-K9 was decided between VNIIFTRI and PTB. It was registered into the BIPM KCDB under the identifier CCEM.RF-K9.1. The results of this comparison were gathered by the pilot laboratory of comparison CCEM.RF-K9, the LNE, and a very good agreement was found between the two participants. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  13. 47 CFR 25.223 - Off-axis EIRP spectral density limits for feeder link earth stations in the 17/24 GHz BSS.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Off-axis EIRP spectral density limits for feeder link earth stations in the 17/24 GHz BSS. 25.223 Section 25.223 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES SATELLITE COMMUNICATIONS Technical Standards § 25...

  14. 47 CFR 25.257 - Special requirements for operations in the band 29.1-29.25 GHz between NGSO MSS and LMDS.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Special requirements for operations in the band 29.1-29.25 GHz between NGSO MSS and LMDS. 25.257 Section 25.257 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES SATELLITE COMMUNICATIONS Technical Standards § 25...

  15. 47 CFR 25.258 - Sharing between NGSO MSS Feeder links Stations and GSO FSS services in the 29.25-29.5 GHz Bands.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Sharing between NGSO MSS Feeder links Stations and GSO FSS services in the 29.25-29.5 GHz Bands. 25.258 Section 25.258 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES SATELLITE COMMUNICATIONS Technical Standards § 25...

  16. 47 CFR 25.213 - Inter-Service coordination requirements for the 1.6/2.4 GHz mobile-satellite service.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Inter-Service coordination requirements for the 1.6/2.4 GHz mobile-satellite service. 25.213 Section 25.213 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES SATELLITE COMMUNICATIONS Technical Standards § 25.213 Inter...

  17. Cold test of cylindrical open resonator for 42 GHz, 200 kW gyrotron

    Indian Academy of Sciences (India)

    particular quality factor for TE mode at the frequency 42 GHz. The perturbation tech ... frequency 42 GHz. The good agreement ... see its performance before the final assembly of the device. This paper .... theoretical work was found. The results ...

  18. Experimental study of a 1 MW, 170 GHz gyrotron oscillator

    Science.gov (United States)

    Kimura, Takuji

    A detailed experimental study is presented of a 1 MW, 170 GHz gyrotron oscillator whose design is consistent with the ECH requirements of the International Thermonuclear Experimental Reactor (ITER) for bulk heating and current drive. This work is the first to demonstrate that megawatt power level at 170 GHz can be achieved in a gyrotron with high efficiency for plasma heating applications. Maximum output power of 1.5 MW is obtained at 170.1 GHz in 85 kV, 50A operation for an efficiency of 35%. Although the experiment at MIT is conducted with short pulses (3 μs), the gyrotron is designed to be suitable for development by industry for continuous wave operation. The peak ohmic loss on the cavity wall for 1 MW of output power is calculated to be 2.3 kW/cm2, which can be handled using present cooling technology. Mode competition problems in a highly over-moded cavity are studied to maximize the efficiency. Various aspects of electron gun design are examined to obtain high quality electron beams with very low velocity spread. A triode magnetron injection gun is designed using the EGUN simulation code. A total perpendicular velocity spread of less than 8% is realized by designing a low- sensitivity, non-adiabatic gun. The RF power is generated in a short tapered cavity with an iris step. The operating mode is the TE28,8,1 mode. A mode converter is designed to convert the RF output to a Gaussian beam. Power and efficiency are measured in the design TE28,8,1 mode at 170.1 GHz as well as the TE27,8,1 mode at 166.6 GHz and TE29,8,1 mode at 173.5 GHz. Efficiencies between 34%-36% are consistently obtained over a wide range of operating parameters. These efficiencies agree with the highest values predicted by the multimode simulations. The startup scenario is investigated and observed to agree with the linear theory. The measured beam velocity ratio is consistent with EGUN simulation. Interception of reflected beam by the mod-anode is measured as a function of velocity ratio

  19. Validation of uncertainty of weighing in the preparation of radionuclide standards by Monte Carlo Method; Validacao da incerteza de pesagens no preparo de padroes de radionuclideos por Metodo de Monte Carlo

    Energy Technology Data Exchange (ETDEWEB)

    Cacais, F.L.; Delgado, J.U., E-mail: facacais@gmail.com [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Loayza, V.M. [Instituto Nacional de Metrologia (INMETRO), Rio de Janeiro, RJ (Brazil). Qualidade e Tecnologia

    2016-07-01

    In preparing solutions for the production of radionuclide metrology standards is necessary measuring the quantity Activity by mass. The gravimetric method by elimination is applied to perform weighing with smaller uncertainties. At this work is carried out the validation, by the Monte Carlo method, of the uncertainty calculation approach implemented by Lourenco and Bobin according to ISO GUM for the method by elimination. The results obtained by both uncertainty calculation methods were consistent indicating that were fulfilled the conditions for the application of ISO GUM in the preparation of radioactive standards. (author)

  20. Do we all agree on how to measure work engagement? Factorial validity of Utrecht Work Engagement Scale as a standard measurement tool - A literature review.

    Science.gov (United States)

    Kulikowski, Konrad

    2017-03-30

    Work engagement as a predictor of health is an emerging concept in occupational science and the Utrecht Work Engagement Scale (UWES) is the most popular work engagement measurement tool. However, despite its popularity, the UWES is not free from controversy concerning its factorial validity. In this paper, 21 research studies on both UWES-9 and UWES-17 factorial validity within the confirmatory factor analysis (CFA) approach have been reviewed in order to answer the question as to which of the UWES factorial structures displays greater validity. The originally proposed threefactor structure of the UWES has been recognized as superior in 6 studies. In further 6 studies, the UWES structure with 1 general factor has been found to be superior. In 8 studies, the authors have concluded that the one- and three-factor structures could be considered equivalent. One study has failed to confirm either the one- or three-factor structure of the UWES. These ambiguous results from studies focusing on the UWES factorial validity are puzzling because they not only indicate a lack of validity for the UWES as a measurement tool but might also challenge the whole concept of work engagement as a three-factor structure of dedication, vigor and absorption. Int J Occup Med Environ Health 2017;30(2):161-175. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  1. Do we all agree on how to measure work engagement? Factorial validity of Utrecht Work Engagement Scale as a standard measurement tool – A literature review

    Directory of Open Access Journals (Sweden)

    Konrad Kulikowski

    2017-04-01

    Full Text Available Work engagement as a predictor of health is an emerging concept in occupational science and the Utrecht Work Engagement Scale (UWES is the most popular work engagement measurement tool. However, despite its popularity, the UWES is not free from controversy concerning its factorial validity. In this paper, 21 research studies on both UWES-9 and UWES-17 factorial validity within the confirmatory factor analysis (CFA approach have been reviewed in order to answer the question as to which of the UWES factorial structures displays greater validity. The originally proposed threefactor structure of the UWES has been recognized as superior in 6 studies. In further 6 studies, the UWES structure with 1 general factor has been found to be superior. In 8 studies, the authors have concluded that the one- and three-factor structures could be considered equivalent. One study has failed to confirm either the one- or three-factor structure of the UWES. These ambiguous results from studies focusing on the UWES factorial validity are puzzling because they not only indicate a lack of validity for the UWES as a measurement tool but might also challenge the whole concept of work engagement as a three-factor structure of dedication, vigor and absorption. Int J Occup Med Environ Health 2017;30(2:161–175

  2. Compact 84 GHz passive mode-locked fiber laser using dual-fiber coupled fused-quartz microresonator

    Science.gov (United States)

    Liu, Tze-An; Hsu, Yung; Chow, Chi-Wai; Chuang, Yi-Chen; Ting, Wei-Jo; Wang, Bo-Chun; Peng, Jin-Long; Chen, Guan-Hong; Chang, Yuan-Chia

    2017-10-01

    We propose and demonstrate a compact and portable-size 84-GHz passive mode-locked fiber laser, in which a dual-fiber coupled fused-quartz microresonator is employed as the intracavity optical comb filter as well as the optical nonlinear material for optical frequency comb generation. About eight coherent optical tones can be generated in the proposed fiber laser. The 20-dB bandwidth is larger than 588 GHz. The full-width half-maximum pulse-width of the proposed laser is 2.5 ps. We also demonstrate the feasibility of using the proposed passive mode-locked fiber laser to carry a 5-Gbit/s on-off-keying signal and transmit over 20-km standard single mode fiber. A 7% forward error correction requirement can be achieved, showing the proposed fiber laser can be a potential candidate for fiber-wireless applications.

  3. A 65 nm CMOS high efficiency 50 GHz VCO with regard to the coupling effect of inductors

    International Nuclear Information System (INIS)

    Ye Yu; Tian Tong

    2013-01-01

    A 50 GHz cross-coupled voltage controlled oscillator (VCO) considering the coupling effect of inductors based on a 65 nm standard complementary metal oxide semiconductor (CMOS) technology is reported. A pair of inductors has been fabricated, measured and analyzed to characterize the coupling effects of adjacent inductors. The results are then implemented to accurately evaluate the VCO's LC tank. By optimizing the tank voltage swing and the buffer's operation region, the VCO achieves a maximum efficiency of 11.4% by generating an average output power of 2.5 dBm while only consuming 19.7 mW (including buffers). The VCO exhibits a phase noise of −87 dBc/Hz at 1 MHz offset, leading to a figure of merit (FoM) of −167.5 dB/Hz and a tuning range of 3.8% (from 48.98 to 50.88 GHz). (semiconductor integrated circuits)

  4. Numerical Simulation of a Double-anode Magnetron Injection Gun for 110 GHz, 1 MW Gyrotron

    Science.gov (United States)

    Singh, Udaybir; Kumar, Nitin; Purohit, L. P.; Sinha, Ashok K.

    2010-07-01

    A 40 A double-anode magnetron injection gun for a 1 MW, 110 GHz gyrotron has been designed. The preliminary design has been obtained by using some trade-off equations. The electron beam analysis has been performed by using the commercially available code EGUN and the in-house developed code MIGANS. The operating mode of the gyrotron is TE22,6 and it is operated in the fundamental harmonic. The electron beam with a low transverse velocity spread ( δ {β_{ bot max }} = 2.26% ) and the transverse-to-axial velocity ratio of the electron beam (α) = 1.37 is obtained. The simulated results of the MIG obtained with the EGUN code have been validated with another trajectory code TRAK. The results on the design output parameters obtained by both the codes are in good agreement. The sensitivity analysis has been carried out by changing the different gun parameters to decide the fabrication tolerance.

  5. Numerical Design of Megawatt Gyrotron with 120 GHz Frequency and 50% Efficiency for Plasma Fusion Application

    Science.gov (United States)

    Kumar, Nitin; Singh, Udaybir; Kumar, Anil; Bhattacharya, Ranajoy; Singh, T. P.; Sinha, A. K.

    2013-02-01

    The design of 120 GHz, 1 MW gyrotron for plasma fusion application is presented in this paper. The mode selection is carried out considering the aim of minimum mode competition, minimum cavity wall heating, etc. On the basis of the selected operating mode, the interaction cavity design and beam-wave interaction computation are carried out by using the PIC code. The design of triode type Magnetron Injection Gun (MIG) is also presented. Trajectory code EGUN, synthesis code MIGSYN and data analysis code MIGANS are used in the MIG designing. Further, the design of MIG is also validated by using the another trajectory code TRAK. The design results of beam dumping system (collector) and RF window are also presented. Depressed collector is designed to enhance the overall tube efficiency. The design study confirms >1 MW output power with tube efficiency around 50% (with collector efficiency).

  6. Dielectric property measurement of ocular tissues up to 110 GHz using 1 mm coaxial sensor

    International Nuclear Information System (INIS)

    Sasaki, K; Isimura, Y; Fujii, K; Wake, K; Watanabe, S; Kojima, M; Suga, R; Hashimoto, O

    2015-01-01

    Measurement of the dielectric properties of ocular tissues up to 110 GHz was performed by the coaxial probe method. A coaxial sensor was fabricated to allow the measurement of small amounts of biological tissues. Four-standard calibration was applied in the dielectric property measurement to obtain more accurate data than that obtained with conventional three-standard calibration, especially at high frequencies. Novel data of the dielectric properties of several ocular tissues are presented and compared with data from the de facto database. (paper)

  7. Ray-Based Statistical Propagation Modeling for Indoor Corridor Scenarios at 15 GHz

    Directory of Open Access Journals (Sweden)

    Qi Wang

    2016-01-01

    Full Text Available According to the demands for fifth-generation (5G communication systems, high frequency bands (above 6 GHz need to be adopted to provide additional spectrum. This paper investigates the characteristics of indoor corridor channels at 15 GHz. Channel measurements with a vector network analyzer in two corridors were conducted. Based on a ray-optical approach, a deterministic channel model covering both antenna and propagation characteristic is presented. The channel model is evaluated by comparing simulated results of received power and root mean square delay spread with the corresponding measurements. By removing the impact of directional antennas from the transmitter and receiver, a path loss model as well as small-scale fading properties for typical corridors is presented based on the generated samples from the deterministic model. Results show that the standard deviation of path loss variation is related to the Tx height, and placing the Tx closer to the ceiling leads to a smaller fluctuation of path loss.

  8. Design of 20-44 GHz broadband doubler MMIC

    International Nuclear Information System (INIS)

    Li Qin; Wang Zhigong; Li Wei

    2010-01-01

    This paper presents the design and performance of a broadband millimeter-wave frequency doubler MMIC using active 0.15 μm GaAs PHEMT and operating at output frequencies from 20 to 44 GHz. This chip is composed of a single ended-into differential-out active Balun, balanced FETs in push-push configuration, and a distributed amplifier. The MMIC doubler exhibits more than 4 dB conversion gain with 12 dBm of output power, and the fundamental frequency suppression is typically -20 dBc up to 44 GHz. The MMIC works at V DD = 3.5 V, V SS = -3.5 V, I d = 200 mA and the chip size is 1.5 x 1.8 mm 2 . (semiconductor integrated circuits)

  9. A 2 MW, CW, 170 GHz gyrotron for ITER

    International Nuclear Information System (INIS)

    Piosczyk, B.; Arnold, A.; Alberti, S.

    2003-01-01

    A 140 GHz gyrotron for CW operation is under development for the stellarator W7-X. With a prototype tube a microwave output power of about 0.9 MW has been obtained in pulses up to 180 s, limited by the capability of the high voltage power supply. The development work on coaxial cavity gyrotrons has demonstrated the feasibility of manufacturing of a 2 MW, CW 170 GHz tube that could be used for ITER. The problems specific to the coaxial arrangement have been investigated and all relevant information needed for an industrial realization of a coaxial gyrotron have been obtained in short pulse experiments (up to 17 ms). The suitability of critical components for a 2 MW, CW coaxial gyrotron has been studied and a first integrated design has been done. (author)

  10. Dielectric Spectroscopy of Biomolecules up to 110 GHz

    Science.gov (United States)

    Laux, Eva-Maria; Ermilova, Elena; Pannwitz, Daniel; Gibbons, Jessica; Hölzel, Ralph; Bier, Frank F.

    2018-03-01

    Radio-frequency fields in the GHz range are increasingly applied in biotechnology and medicine. In order to fully exploit both their potential and their risks detailed information about the dielectric properties of biological material is needed. For this purpose a measuring system is presented that allows the acquisition of complex dielectric spectra over 4 frequency decade up to 110 GHz. Routines for calibration and for data evaluation according to physicochemical interaction models have been developed. The frequency dependent permittivity and dielectric loss of some proteins and nucleic acids, the main classes of biomolecules, and of their sub-units have been determined. Dielectric spectra are presented for the amino acid alanine, the proteins lysozyme and haemoglobin, the nucleotides AMP and ATP, and for the plasmid pET-21, which has been produced by bacterial culture. Characterisation of a variety of biomolecules is envisaged, as is the application to studies on protein structure and function.

  11. 100 GHz, 1 MW, CW gyrotron study program. Final report

    International Nuclear Information System (INIS)

    Felch, K.; Bier, R.; Caplan, M.; Jory, H.

    1983-09-01

    The results of a study program to investigate the feasibility of various approaches in designing a 100 GHz, 1 MW CW gyrotron are presented. A summary is given of the possible configurations for a high average power, high frequency gyrotron, including an historical survey of experimental results which are relevant to the various approaches. A set of basic scaling considerations which enable qualitative comparisons between particular gyrotron interaction circuits is presented. These calculations are important in understanding the role of various electron beam and circuit parameters in achieving a viable gyrotron design. Following these scaling exercises, a series of design calculations is presented for a possible approach in achieving 100 GHz, 1 MW CW. These calculations include analyses of the electron gun and interaction circuit parts of the gyrotron, and a general analysis of other aspects of a high average power, high frequency gyrotron. Scalability of important aspects of the design to other frequencies is also discussed, as well as key technology issues

  12. Future mobile satellite communication concepts at 20/30 GHz

    Science.gov (United States)

    Barton, S. K.; Norbury, J. R.

    1990-01-01

    The outline of a design of a system using ultra small earth stations (picoterminals) for data traffic at 20/30 GHz is discussed. The picoterminals would be battery powered, have an RF transmitter power of 0.5 W, use a 10 cm square patch antenna, and have a receiver G/T of about -8 dB/K. Spread spectrum modulation would be required (due to interference consideration) to allow a telex type data link (less than 200 bit/s data rate) from the picoterminal to the hub station of the network and about 40 kbit/s on the outbound patch. An Olympus type transponder at 20/30 GHz could maintain several thousand simultaneous picoterminal circuits. The possibility of demonstrating a picoterminal network with voice traffic using Olympus is discussed together with fully mobile systems based on this concept.

  13. Influence of Noises on Remote State Preparation Using GHZ State

    International Nuclear Information System (INIS)

    Liang Huaqiu; Liu Jinming

    2008-01-01

    Using a quantum channel consisting of a GHZ state exposed to noisy environment, we investigate how to remotely prepare an entangled state and a qubit state, respectively. By solving the master equation in the Lindblad form, the influence of the various types of noises on the GHZ state is first discussed. Then we use the fidelity to describe how close the remotely prepared state and the initial state are. Our results show that the fidelity is a function of the decoherence rates and the angles of the initial state. It is found that for each of the two RSP schemes, the influence of the noise acting simultaneously in x, y, and z directions on the average fidelity is the strongest while the influence of the noise acting in x or z direction on the average fidelity is relatively weaker

  14. An Automatic Control System for Conditioning 30 GHz Accelerating Structures

    CERN Document Server

    Dubrovskiy, A

    2008-01-01

    A software application programme has been developed to allow fast and automatic high-gradient conditioning of accelerating structures at 30 GHz in CTF3. The specificity of the application is the ability to control the high-power electron beam which produces the 30 GHz RF power used to condition the accelerating structures. The programme permits operation round the clock with minimum manpower requirements. In this paper the fast control system, machine control system, logging system, graphical user control interface and logging data visualization are described. An outline of the conditioning control system itself and of the feedback controlling peak power and pulse length is given. The software allows different types of conditioning strategies to be programmed

  15. Quantum Steganography via Greenberger-Horne-Zeilinger GHZ4 State

    International Nuclear Information System (INIS)

    El Allati, A.; Hassouni, Y.; Medeni, M.B. Ould

    2012-01-01

    A quantum steganography communication scheme via Greenberger-Horne-Zeilinger GHZ 4 state is constructed to investigate the possibility of remotely transferred hidden information. Moreover, the multipartite entangled states are become a hectic topic due to its important applications and deep effects on aspects of quantum information. Then, the scheme consists of sharing the correlation of four particle GHZ 4 states between the legitimate users. After insuring the security of the quantum channel, they begin to hide the secret information in the cover of message. Comparing the scheme with the previous quantum steganographies, capacity and imperceptibility of hidden message are good. The security of the present scheme against many attacks is also discussed. (general)

  16. The 30/20 GHz communications satellite trunking network study

    Science.gov (United States)

    Kolb, W.

    1981-01-01

    Alternative transmission media for a CONUS-wide trunking network in the years 1990 and 2000 are examined. The alternative technologies comprised fiber optic cable, conventional C- and Ku-band satellites, and 30/20 GHz satellites. Three levels of implementation were considered - a 10-city network, a 20-city network, and a 40-city network. The cities selected were the major metropolitan areas with the greatest communications demand. All intercity voice, data, and video traffic carried more than 40 miles was included in the analysis. In the optimized network, traffic transmitted less than 500 miles was found to be better served by fiber optic cable in 1990. By the year 2000, the crossover point would be down to 200 miles, assuming availability of 30/20 GHz satellites.

  17. InP Heterojunction Bipolar Transistor Amplifiers to 255 GHz

    Science.gov (United States)

    Radisic, Vesna; Sawdai, Donald; Scott, Dennis; Deal, William; Dang, Linh; Li, Danny; Cavus, Abdullah; To, Richard; Lai, Richard

    2009-01-01

    Two single-stage InP heterojunction bipolar transistor (HBT) amplifiers operate at 184 and 255 GHz, using Northrop Grumman Corporation s InP HBT MMIC (monolithic microwave integrated circuit) technology. At the time of this reporting, these are reported to be the highest HBT amplifiers ever created. The purpose of the amplifier design is to evaluate the technology capability for high-frequency designs and verify the model for future development work.

  18. Startup and mode competition in a 420 GHz gyrotron

    Science.gov (United States)

    Qixiang Zhao, A.; Sheng Yu, B.; Tianzhong Zhang, C.

    2017-09-01

    In the experiments of a 420 GHz second-harmonic gyrotron, it is found that the electron beam voltage and current ranges for single mode operation of TE17.4 are slightly narrower than those in the simulation. To explain this phenomenon, the startup scenario has been investigated with special emphasis on mode competition. The calculations indicate that the decreases of the operating ranges are caused by the voltage overshoot in the startup scenario.

  19. Construction of a 35 GHz 100 kW gyrotron

    International Nuclear Information System (INIS)

    Aso, Y.; Barroso, J.J.; Castro, P.J.; Correa, R.A.; Ludwing, G.O.; Montes, A.; Morgado, U.T.F.; Nono, M.C.A.; Rossi, J.O.; Silva, P.R.

    1989-09-01

    In this work a description of a 35 GHz 100 kW gyrocon is described which is under construction at the National Space Research Institute Plasma Laboratory. Project conceptual aspects are emphasized, specifically high current density thermionic cathodes, high time and spatial resolution intense magnetic fields generation, high-vacuum systems, techniques of ceramic-metal sealing, and high-voltage electrical modulator circuits. (author). 8 refs., 9 figs., 1 tab

  20. An 8–18 GHz broadband high power amplifier

    International Nuclear Information System (INIS)

    Wang Lifa; Yang Ruixia; Li Yanlei; Wu Jingfeng

    2011-01-01

    An 8–18 GHz broadband high power amplifier (HPA) with a hybrid integrated circuit (HIC) is designed and fabricated. This HPA is achieved with the use of a 4-fingered micro-strip Lange coupler in a GaAs MMIC process. In order to decrease electromagnetic interference, a multilayer AlN material with good heat dissipation is adopted as the carrier of the power amplifier. When the input power is 25 dBm, the saturated power of the continuous wave (CW) outputted by the power amplifier is more than 39 dBm within the frequency range of 8–13 GHz, while it is more than 38.6 dBm within other frequency ranges. We obtain the peak power output, 39.4 dBm, at the frequency of 11.9 GHz. In the whole frequency band, the power-added efficiency is more than 18%. When the input power is 18 dBm, the small signal gain is 15.7 ± 0.7 dB. The dimensions of the HPA are 25 × 15 × 1.5 mm 3 . (semiconductor integrated circuits)

  1. GHz band frequency hopping PLL-based frequency synthesizers

    Institute of Scientific and Technical Information of China (English)

    XU Yong; WANG Zhi-gong; GUAN Yu; XU Zhi-jun; QIAO Lu-feng

    2005-01-01

    In this paper we describe a full-integrated circuit containing all building blocks of a completed PLL-based synthesizer except for low pass filter(LPF).The frequency synthesizer is designed for a frequency hopping (FH) transceiver operating up to 1.5 GHz as a local oscillator. The architecture of Voltage Controlled Oscillator (VCO) is optimized to get better performance, and a phase noise of -111.85-dBc/Hz @ 1 MHz and a tuning range of 250 MHz are gained at a centre frequency of 1.35 GHz.A novel Dual-Modulus Prescaler(DMP) is designed to achieve a very low jitter and a lower power.The settling time of PLL is 80 μs while the reference frequency is 400 KHz.This monolithic frequency synthesizer is to integrate all main building blocks of PLL except for the low pass filter,with a maximum VCO output frequency of 1.5 GHz,and is fabricated with a 0.18 μm mixed signal CMOS process. Low power dissipation, low phase noise, large tuning range and fast settling time are gained in this design.

  2. A 12 GHz RF Power Source for the CLIC Study

    Energy Technology Data Exchange (ETDEWEB)

    Schirm, Karl; /CERN; Curt, Stephane; /CERN; Dobert, Steffen; /CERN; McMonagle, Gerard; /CERN; Rossat, Ghislain; /CERN; Syratchev, Igor; /CERN; Timeo, Luca; /CERN; Haase, Andrew /SLAC; Jensen, Aaron; /SLAC; Jongewaard, Erik; /SLAC; Nantista, Christopher; /SLAC; Sprehn, Daryl; /SLAC; Vlieks, Arnold; /SLAC; Hamdi, Abdallah; /Saclay; Peauger, Franck; /Saclay; Kuzikov, Sergey; /Nizhnii Novgorod, IAP; Vikharev, Alexandr; /Nizhnii Novgorod, IAP

    2012-07-03

    The CLIC RF frequency has been changed in 2008 from the initial 30 GHz to the European X-band 11.9942 GHz permitting beam independent power production using klystrons for CLIC accelerating structure testing. A design and fabrication contract for five klystrons at that frequency has been signed by different parties with SLAC. France (IRFU, CEA Saclay) is contributing a solid state modulator purchased in industry and specific 12 GHz RF network components to the CLIC study. RF pulses over 120 MW peak at 230 ns length will be obtained by using a novel SLED-I type pulse compression scheme designed and fabricated by IAP, Nizhny Novgorod, Russia. The X-band power test stand is being installed in the CLIC Test Facility CTF3 for independent structure and component testing in a bunker, but allowing, in a later stage, for powering RF components in the CTF3 beam lines. The design of the facility, results from commissioning of the RF power source and the expected performance of the Test Facility are reported.

  3. CARM and harmonic gyro-amplifier experiments at 17 GHz

    International Nuclear Information System (INIS)

    Menninger, W.L.; Danly, B.G.; Alberti, S.; Chen, C.; Rullier, J.L.; Temkin, R.J.

    1993-01-01

    Cyclotron resonance maser amplifiers are possible sources for applications such as electron cyclotron resonance heating of fusion plasmas and driving high-gradient rf linear accelerators. For accelerator drivers, amplifiers or phase locked-oscillators are required. A 17 GHz cyclotron autoresonance maser (CARM) amplifier experiment and a 17 GHz third harmonic gyro-amplifier experiment are presently underway at the MIT Plasma Fusion Center. Using the SRL/MIT SNOMAD II introduction accelerator to provide a 380 kV, 180 A, 30 ns flat top electron beam, the gyro-amplifier experiment has produced 5 MW of rf power with over 50 dB of gain at 17 GHz. The gyro-amplifier operates in the TE 31 mode using a third harmonic interaction. Because of its high power output, the gyro-amplifier will be used as the rf source for a photocathode rf electron gun experiment also taking place at MIT. Preliminary gyro-amplifier results are presented, including measurement of rf power, gain versus interaction length, and the far-field pattern. A CARM experiment designed to operate in the TE 11 mode is also discussed

  4. LFI 30 and 44 GHz receivers Back-End Modules

    International Nuclear Information System (INIS)

    Artal, E; Aja, B; Fuente, M L de la; Pascual, J P; Mediavilla, A; Martinez-Gonzalez, E; Pradell, L; Paco, P de; Bara, M; Blanco, E; GarcIa, E; Davis, R; Kettle, D; Roddis, N; Wilkinson, A; Bersanelli, M; Mennella, A; Tomasi, M; Butler, R C; Cuttaia, F

    2009-01-01

    The 30 and 44 GHz Back End Modules (BEM) for the Planck Low Frequency Instrument are broadband receivers (20% relative bandwidth) working at room temperature. The signals coming from the Front End Module are amplified, band pass filtered and finally converted to DC by a detector diode. Each receiver has two identical branches following the differential scheme of the Planck radiometers. The BEM design is based on MMIC Low Noise Amplifiers using GaAs P-HEMT devices, microstrip filters and Schottky diode detectors. Their manufacturing development has included elegant breadboard prototypes and finally qualification and flight model units. Electrical, mechanical and environmental tests were carried out for the characterization and verification of the manufactured BEMs. A description of the 30 and 44 GHz Back End Modules of Planck-LFI radiometers is given, with details of the tests done to determine their electrical and environmental performances. The electrical performances of the 30 and 44 GHz Back End Modules: frequency response, effective bandwidth, equivalent noise temperature, 1/f noise and linearity are presented.

  5. A 12 GHZ RF Power source for the CLIC study

    CERN Document Server

    Peauger, F; Curt, S; Doebert, S; McMonagle, G; Rossat, G; Schirm, KM; Syratchev, I; Timeo, L; Kuzikhov, S; Vikharev, AA; Haase, A; Sprehn, D; Jensen, A; Jongewaard, EN; Nantista, CD; Vlieks, A

    2010-01-01

    The CLIC RF frequency has been changed in 2008 from the initial 30 GHz to the European X-band 11.9942 GHz permitting beam independent power production using klystrons for CLIC accelerating structure testing. A design and fabrication contract for five klystrons at that frequency has been signed by different parties with SLAC. France (IRFU, CEA Saclay) is contributing a solid state modulator purchased in industry and specific 12 GHz RF network components to the CLIC study. RF pulses over 120 MW peak at 230 ns length will be obtained by using a novel SLED-I type pulse compression scheme designed and fabricated by IAP, Nizhny Novgorod, Russia. The X-band power test stand is being installed in the CLIC Test Facility CTF3 for independent structure and component testing in a bunker, but allowing, in a later stage, for powering RF components in the CTF3 beam lines. The design of the facility, results from commissioning of the RF power source and the expected performance of the Test Facility are reported.

  6. GHz Yb:KYW oscillators in time-resolved spectroscopy

    Science.gov (United States)

    Li, Changxiu; Krauß, Nico; Schäfer, Gerhard; Ebner, Lukas; Kliebisch, Oliver; Schmidt, Johannes; Winnerl, Stephan; Hettich, Mike; Dekorsy, Thomas

    2018-02-01

    A high-speed asynchronous optical sampling system (ASOPS) based on Yb:KYW oscillators with 1-GHz repetition rate is reported. Two frequency-offset-stabilized diode-pumped Yb:KYW oscillators are employed as pump and probe source, respectively. The temporal resolution of this system within 1-ns time window is limited to 500 fs and the noise floor around 10-6 (ΔR/R) close to the shot-noise level is obtained within an acquisition time of a few seconds. Coherent acoustic phonons are investigated by measuring multilayer semiconductor structures with multiple quantum wells and aluminum/silicon membranes in this ASOPS system. A wavepacket-like phonon sequence at 360 GHz range is detected in the semiconductor structures and a decaying sequence of acoustic oscillations up to 200 GHz is obtained in the aluminum/silicon membranes. Coherent acoustic phonons generated from semiconductor structures are further manipulated by a double pump scheme through pump time delay control.

  7. Label free sensing of creatinine using a 6 GHz CMOS near-field dielectric immunosensor.

    Science.gov (United States)

    Guha, S; Warsinke, A; Tientcheu, Ch M; Schmalz, K; Meliani, C; Wenger, Ch

    2015-05-07

    In this work we present a CMOS high frequency direct immunosensor operating at 6 GHz (C-band) for label free determination of creatinine. The sensor is fabricated in standard 0.13 μm SiGe:C BiCMOS process. The report also demonstrates the ability to immobilize creatinine molecules on a Si3N4 passivation layer of the standard BiCMOS/CMOS process, therefore, evading any further need of cumbersome post processing of the fabricated sensor chip. The sensor is based on capacitive detection of the amount of non-creatinine bound antibodies binding to an immobilized creatinine layer on the passivated sensor. The chip bound antibody amount in turn corresponds indirectly to the creatinine concentration used in the incubation phase. The determination of creatinine in the concentration range of 0.88-880 μM is successfully demonstrated in this work. A sensitivity of 35 MHz/10 fold increase in creatinine concentration (during incubation) at the centre frequency of 6 GHz is gained by the immunosensor. The results are compared with a standard optical measurement technique and the dynamic range and sensitivity is of the order of the established optical indication technique. The C-band immunosensor chip comprising an area of 0.3 mm(2) reduces the sensing area considerably, therefore, requiring a sample volume as low as 2 μl. The small analyte sample volume and label free approach also reduce the experimental costs in addition to the low fabrication costs offered by the batch fabrication technique of CMOS/BiCMOS process.

  8. Toward an international standard for PCR-based detection of Escherichia coli O157 - Part 1. Assay development and multi-center validation

    DEFF Research Database (Denmark)

    Abdulmawjood, A.; Bulte, M.; Cook, N.

    2003-01-01

    As part of a major European research project, a diagnostic PCR assay, including an internal amplification control, was developed and validated in a collaborative trial for the detection of Escherichia coli O157. The assay is based on amplification of sequences of the rJbE O157 gene. The collabora...

  9. Early identification of children at-risk for academic difficulties, using standardized assessment: stability and predictive validity of preschool math and language scores

    NARCIS (Netherlands)

    Frans, Niek; Post, Wendy J.; Huisman, Mark; Oenema-Mostert, Ineke C.E.; Keegstra, Anne L.; Minnaert, Alexander E.M.G.

    2017-01-01

    Despite the claim by several researchers that variability in performance may complicate the identification of “at-risk” children, variability in the academic performance of young children remains an undervalued area of research. The goal of this study is to examine the predictive validity for future

  10. 200 and 270 GHz SIS receivers development for atmospheric observation

    International Nuclear Information System (INIS)

    Ochiai, S.; Masuko, H.

    1993-01-01

    Superconducting mixers have been developed for observations of atmospheric minor constituents such as ClO and ozone at Communications Research Laboratory. This paper describes the work at development of 200 and 270 GHz SIS mixers. Nb/AlOx/Nb junctions were fabricated at Nobeyama Radio Observatory. The base Nb layer 200 nm, the Al (AlOx) insulation layer, and the counter Nb electrode 150 nm are sputtered. The area outside of a junction defined by etching of the counter electrode is insulated by anodized Nb layer and sputtered SiO 2 . After sputtering thick SiO 2 layer on the whole wafer, a contact hole is made by etching. The thickness of the wiring Nb layer is 500 nm. The junctions are formed on the 250 μm thick fused quartz substrate. After the process of the junction fabrication, the quartz substrate is shaved from the back side until 150 μm thickness. Each junction for 270 GHz mixer has an area of about 1 μm 2 . The normal resistance of the six junctions series array is around 70 Ω. The mixer block has a reduced waveguide (1.2 x 0.1 mm for 200 GHz and 0.98 x 0. 1 mm for 270 GHz). The waveguide has two tuners in addition to a fixed backshort cavity. This configuration can allow to realize the lower embedding impedance, and less sensitive to the position of the tuners. The SIS mixers are cooled in a closed cycle He refrigerator. The LO is optically injected through a Fabry Perot interferometer. The 5--7 GHz IF is fed to a HEMT amplifier cooled at 15 K. The authors have started a preliminary measurement of the noise temperature of the SIS receivers, and comparing with calculated DSB receiver noise temperature assuming 3-port model. They continue to improve the performance of the SIS mixers now. They intend that the receivers shall be utilized for atmospheric monitor from next winter

  11. The validation of the standard Chinese version of the European Organization for Research and Treatment of Cancer Quality of Life Core Questionnaire 30 (EORTC QLQ-C30 in pre-operative patients with brain tumor in China

    Directory of Open Access Journals (Sweden)

    Zhang Hong-ying

    2011-04-01

    Full Text Available Abstract Background Health related quality of life (HRQOL has increasingly emphasized on cancer patients. The psychometric properties of the standard Chinese version of the European Organization for Research and Treatment of Cancer Quality of Life Core Questionnaire 30 (EORTC QLQ-C30, version 3.0 in brain tumor patients wasn't proven, and there was no baseline HRQOL in brain tumor patients prior to surgery. Methods The questionnaire EORTC QLQ-C30 (version 3.0 was administered at three time points: T1, the first or the second day that patients were hospitalized after the brain tumor suspected or diagnosed by MRI or CT; T2, 1 to 2 days after T1, (T1 and T2 were both before surgery; T3, the day before discharge. Clinical variables included disease histologic types, cognitive function, and Karnofsky Performance Status. Results Cronbach's alpha coefficients for multi-item scales were greater than .70 and multitrait scaling analysis showed that most of the item-scale correlation coefficients met the standards of convergent and discriminant validity, except for the cognitive functioning scale. All scales and items exhibited construct validity. Score changes over peri-operation were observed in physical and role functioning scales. Compared with mixed cancer patients assessed after surgery but before adjuvant treatment, brain tumor patients assessed pre-surgery presented better function and fewer symptoms. Conclusions The standard Chinese version of the EORTC QLQ-C30 was overall a valid instrument to assess HRQOL in brain tumor patients in China. The baseline HRQOL in brain tumor patients pre-surgery was better than that in mixed cancer patients post-surgery. Future study should modify cognitive functioning scale and examine test-retest reliability and response validity.

  12. Experimental design and reporting standards for improving the internal validity of pre-clinical studies in the field of pain: Consensus of the IMI-Europain consortium

    DEFF Research Database (Denmark)

    Knopp, K.L.; Stenfors, C.; Baastrup, Cathrine Søndergaard

    2015-01-01

    that recommendations on how to improve these factors are warranted. Methods Members of Europain, a pain research consortium funded by the European Innovative Medicines Initiative (IMI), developed internal recommendations on how to improve the reliability of pre-clinical studies between laboratories. This guidance...... and conduct, and data analysis and interpretation. Key principles such as sample size calculation, a priori definition of a primary efficacy measure, randomization, allocation concealments, and blinding are discussed. In addition, considerations of how stress and normal rodent physiology impact outcome...... development in order to estimate possible publication bias is discussed. Conclusions More systematic research is needed to analyze how inadequate internal validity and/or experimental bias may impact reproducibility across pre-clinical pain studies. Addressing the potential threats to internal validity...

  13. Application of NEA/CSNI standard problem 3 (blowdown and flow reversal in the IETA-1 rig) to the validation of the RELAP-UK Mk IV code

    International Nuclear Information System (INIS)

    Bryce, W.M.

    1977-10-01

    NEA/CSNI Standard Problem 3 consists of the modelling of an experiment on the IETI-1 rig, in which there is initially flow upwards through a feeder, heated section and riser. The inlet and outlet are then closed and a breach opened at the bottom so that the flow reverses and the rig depressurises. Calculations of this problem by many countries using several computer codes have been reported and show a wide spread of results. The purpose of the study reported here was the following. First, to show the sensitivity of the calculation of Standard Problem 3. Second, to perform an ab initio best estimate calculation using the RELAP-UK Mark IV code with the standard recommended options, and third, to use the results of the sensitivity study to show where tuning of the RELAP-UK Mark IV recommended model options was required. This study has shown that the calculation of Standard Problem 3 is sensitive to model assumptions and that the use of the loss-of-coolant accident code RELAP-UK Mk IV with the standard recommended model options predicts the experimental results very well over most of the transient. (U.K.)

  14. Design of a 5 GHz window in a lower hybrid r.f. system

    International Nuclear Information System (INIS)

    Maebara, S.; Ikeda, Y.; Seki, M.; Imai, T.

    1995-01-01

    A new pill-box window at a frequency of 5GHz, which has an oversized length in both the axial and the radial direction, has been designed to reduce the r.f. power density and the electric field strength at the ceramics. The dimension of the new pill-box is optimized from the numerical calculation and a voltage standing-wave ratio of less than 1.02 is obtained. The r.f. power density and the maximum electric field strength are reduced to about 40% and 66% of the standard pill-box window respectively. It is evaluated that the power capability of the new oversized pill-box window by cooling edge of ceramics is more than 500kW with continuous-wave operation. ((orig.))

  15. The generation of shared cryptographic keys through channel impulse response estimation at 60 GHz.

    Energy Technology Data Exchange (ETDEWEB)

    Young, Derek P.; Forman, Michael A.; Dowdle, Donald Ryan

    2010-09-01

    Methods to generate private keys based on wireless channel characteristics have been proposed as an alternative to standard key-management schemes. In this work, we discuss past work in the field and offer a generalized scheme for the generation of private keys using uncorrelated channels in multiple domains. Proposed cognitive enhancements measure channel characteristics, to dynamically change transmission and reception parameters as well as estimate private key randomness and expiration times. Finally, results are presented on the implementation of a system for the generation of private keys for cryptographic communications using channel impulse-response estimation at 60 GHz. The testbed is composed of commercial millimeter-wave VubIQ transceivers, laboratory equipment, and software implemented in MATLAB. Novel cognitive enhancements are demonstrated, using channel estimation to dynamically change system parameters and estimate cryptographic key strength. We show for a complex channel that secret key generation can be accomplished on the order of 100 kb/s.

  16. Design of 2.4Ghz CMOS Floating Active Inductor LNA using 130nm Technology

    Science.gov (United States)

    Muhamad, M.; Soin, N.; Ramiah, H.

    2018-03-01

    This paper presents about design and optimization of CMOS active inductor integrated circuit. This active inductor implements using Silterra 0.13μm technology and simulated using Cadence Virtuoso and Spectre RF. The center frequency for this active inductor is at 2.4 GHz which follow IEEE 802.11 b/g/n standard. To reduce the chip size of silicon, active inductor is used instead of passive inductor at low noise amplifier LNA circuit. This inductor test and analyse by low noise amplifier circuit. Comparison between active with passive inductor based on LNA circuit has been performed. Result shown that the active inductor has significantly reduce the chip size with 73 % area without sacrificing the noise figure and gain of LNA which is the most important criteria in LNA. The best low noise amplifier provides a power gain (S21) of 20.7 dB with noise figure (NF) of 2.1dB.

  17. 47 CFR 25.143 - Licensing provisions for the 1.6/2.4 GHz mobile-satellite service and 2 GHz mobile-satellite...

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Licensing provisions for the 1.6/2.4 GHz mobile-satellite service and 2 GHz mobile-satellite service. 25.143 Section 25.143 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES SATELLITE COMMUNICATIONS Applications and Licenses...

  18. 47 CFR 25.139 - NGSO FSS coordination and information sharing between MVDDS licensees in the 12.2 GHz to 12.7 GHz...

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false NGSO FSS coordination and information sharing between MVDDS licensees in the 12.2 GHz to 12.7 GHz band. 25.139 Section 25.139 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES SATELLITE COMMUNICATIONS Applications and Licenses...

  19. Validation of the Welch Allyn SureBP (inflation) and StepBP (deflation) algorithms by AAMI standard testing and BHS data analysis.

    Science.gov (United States)

    Alpert, Bruce S

    2011-04-01

    We evaluated two new Welch Allyn automated blood pressure (BP) algorithms. The first, SureBP, estimates BP during cuff inflation; the second, StepBP, does so during deflation. We followed the American National Standards Institute/Association for the Advancement of Medical Instrumentation SP10:2006 standard for testing and data analysis. The data were also analyzed using the British Hypertension Society analysis strategy. We tested children, adolescents, and adults. The requirements of the American National Standards Institute/Association for the Advancement of Medical Instrumentation SP10:2006 standard were fulfilled with respect to BP levels, arm sizes, and ages. Association for the Advancement of Medical Instrumentation SP10 Method 1 data analysis was used. The mean±standard deviation for the device readings compared with auscultation by paired, trained, blinded observers in the SureBP mode were -2.14±7.44 mmHg for systolic BP (SBP) and -0.55±5.98 mmHg for diastolic BP (DBP). In the StepBP mode, the differences were -3.61±6.30 mmHg for SBP and -2.03±5.30 mmHg for DBP. Both algorithms achieved an A grade for both SBP and DBP by British Hypertension Society analysis. The SureBP inflation-based algorithm will be available in many new-generation Welch Allyn monitors. Its use will reduce the time it takes to estimate BP in critical patient care circumstances. The device will not need to inflate to excessive suprasystolic BPs to obtain the SBP values. Deflation is rapid once SBP has been determined, thus reducing the total time of cuff inflation and reducing patient discomfort. If the SureBP fails to obtain a BP value, the StepBP algorithm is activated to estimate BP by traditional deflation methodology.

  20. Derivation and Validation of a Risk Standardization Model for Benchmarking Hospital Performance for Health-Related Quality of Life Outcomes after Acute Myocardial Infarction

    Science.gov (United States)

    Arnold, Suzanne V.; Masoudi, Frederick A.; Rumsfeld, John S.; Li, Yan; Jones, Philip G.; Spertus, John A.

    2014-01-01

    Background Before outcomes-based measures of quality can be used to compare and improve care, they must be risk-standardized to account for variations in patient characteristics. Despite the importance of health-related quality of life (HRQL) outcomes among patients with acute myocardial infarction (AMI), no risk-standardized models have been developed. Methods and Results We assessed disease-specific HRQL using the Seattle Angina Questionnaire at baseline and 1 year later in 2693 unselected AMI patients from 24 hospitals enrolled in the TRIUMPH registry. Using 57 candidate sociodemographic, economic, and clinical variables present on admission, we developed a parsimonious, hierarchical linear regression model to predict HRQL. Eleven variables were independently associated with poor HRQL after AMI, including younger age, prior CABG, depressive symptoms, and financial difficulties (R2=20%). The model demonstrated excellent internal calibration and reasonable calibration in an independent sample of 1890 AMI patients in a separate registry, although the model slightly over-predicted HRQL scores in the higher deciles. Among the 24 TRIUMPH hospitals, 1-year unadjusted HRQL scores ranged from 67–89. After risk-standardization, HRQL scores variability narrowed substantially (range=79–83), and the group of hospital performance (bottom 20%/middle 60%/top 20%) changed in 14 of the 24 hospitals (58% reclassification with risk-standardization). Conclusions In this predictive model for HRQL after AMI, we identified risk factors, including economic and psychological characteristics, associated with HRQL outcomes. Adjusting for these factors substantially altered the rankings of hospitals as compared with unadjusted comparisons. Using this model to compare risk-standardized HRQL outcomes across hospitals may identify processes of care that maximize this important patient-centered outcome. PMID:24163068

  1. Derivation and validation of a risk standardization model for benchmarking hospital performance for health-related quality of life outcomes after acute myocardial infarction.

    Science.gov (United States)

    Arnold, Suzanne V; Masoudi, Frederick A; Rumsfeld, John S; Li, Yan; Jones, Philip G; Spertus, John A

    2014-01-21

    Before outcomes-based measures of quality can be used to compare and improve care, they must be risk-standardized to account for variations in patient characteristics. Despite the importance of health-related quality of life (HRQL) outcomes among patients with acute myocardial infarction (AMI), no risk-standardized models have been developed. We assessed disease-specific HRQL using the Seattle Angina Questionnaire at baseline and 1 year later in 2693 unselected AMI patients from 24 hospitals enrolled in the Translational Research Investigating Underlying disparities in acute Myocardial infarction Patients' Health status (TRIUMPH) registry. Using 57 candidate sociodemographic, economic, and clinical variables present on admission, we developed a parsimonious, hierarchical linear regression model to predict HRQL. Eleven variables were independently associated with poor HRQL after AMI, including younger age, previous coronary artery bypass graft surgery, depressive symptoms, and financial difficulties (R(2)=20%). The model demonstrated excellent internal calibration and reasonable calibration in an independent sample of 1890 AMI patients in a separate registry, although the model slightly overpredicted HRQL scores in the higher deciles. Among the 24 TRIUMPH hospitals, 1-year unadjusted HRQL scores ranged from 67-89. After risk-standardization, HRQL score variability narrowed substantially (range=79-83), and the group of hospital performance (bottom 20%/middle 60%/top 20%) changed in 14 of the 24 hospitals (58% reclassification with risk-standardization). In this predictive model for HRQL after AMI, we identified risk factors, including economic and psychological characteristics, associated with HRQL outcomes. Adjusting for these factors substantially altered the rankings of hospitals as compared with unadjusted comparisons. Using this model to compare risk-standardized HRQL outcomes across hospitals may identify processes of care that maximize this important patient

  2. Standardization of the Korean version of Mini-Mental Adjustment to Cancer (K-Mini-MAC) scale: factor structure, reliability and validity.

    Science.gov (United States)

    Kang, Jee In; Chung, Hyun Cheol; Kim, Se Joo; Choi, Hye Jin; Ahn, Joong Bae; Jeung, Hei-Cheul; Namkoong, Kee

    2008-06-01

    Mental adjustment and coping affect the physical outcome and survival as well as quality of life in cancer patients. The Mini-Mental Adjustment to Cancer (Mini-MAC) scale is a new refined, economical and reliable self-rating instrument measuring cognitive and behavioral responses to cancer. The aim of this study was to evaluate the psychometric properties of the Mini-MAC in Korean cancer patients. A total of 208 cancer patients recruited from the Yonsei Cancer Center were assessed with the Mini-MAC and the Hospital Anxiety and Depression Scale (HADS). Principal component analysis with varimax rotation for the Korean version of Mini-MAC (K-Mini-MAC) confirmed four factors. Three had psychometric properties similar to Helpless-Hopeless (HH), Anxious Preoccupation (AP) and Cognitive Avoidance (CA) of the original Mini-MAC. A novel factor, named Positive Attitude, included items of both Fatalism (FA) and Fighting Spirit (FS) from the original version. The five subscales from the original version (AP, HH, FS, FA and CA) and Positive Attitude had acceptable internal reliabilities in our sample (Cronbach's alpha coefficient 0.50-0.86; correlation coefficient of test-retest 0.68-0.88). For the validity, significant interscale correlation was observed in the original five subscales and Positive Attitude. Each subscale including Positive Attitude was also significantly related to Depression and Anxiety of HADS. As a whole, the K-Mini-MAC was a reliable, valid and acceptable tool for Korean cancer patients. These findings can provide information about the cross-cultural validity of Mini-MAC scale's factor structure. Cultural differences were also discussed.

  3. Absolute, pressure-dependent validation of a calibration-free, airborne laser hygrometer transfer standard (SEALDH-II from 5 to 1200 ppmv using a metrological humidity generator

    Directory of Open Access Journals (Sweden)

    B. Buchholz

    2018-01-01

    Full Text Available Highly accurate water vapor measurements are indispensable for understanding a variety of scientific questions as well as industrial processes. While in metrology water vapor concentrations can be defined, generated, and measured with relative uncertainties in the single percentage range, field-deployable airborne instruments deviate even under quasistatic laboratory conditions up to 10–20 %. The novel SEALDH-II hygrometer, a calibration-free, tuneable diode laser spectrometer, bridges this gap by implementing a new holistic concept to achieve higher accuracy levels in the field. We present in this paper the absolute validation of SEALDH-II at a traceable humidity generator during 23 days of permanent operation at 15 different H2O mole fraction levels between 5 and 1200 ppmv. At each mole fraction level, we studied the pressure dependence at six different gas pressures between 65 and 950 hPa. Further, we describe the setup for this metrological validation, the challenges to overcome when assessing water vapor measurements on a high accuracy level, and the comparison results. With this validation, SEALDH-II is the first airborne, metrologically validated humidity transfer standard which links several scientific airborne and laboratory measurement campaigns to the international metrological water vapor scale.

  4. Standard model parameters determination and validity tests in Z{sup 0} hadronic disintegrations; Determination des parametres du modele standard et tests de sa validite dans les desintegrations hadroniques du Z{sup 0}

    Energy Technology Data Exchange (ETDEWEB)

    Todorov, T

    1993-05-01

    This thesis describes the determination of the electroweak parameters from the measurements of the total hadronic cross-section by the DELPHI experiment at LEP-I. The analysed data was taken in the years 1991 and 1992; a previous analysis of the data taken in 1990 is included in the final fits. The first part of the thesis describes the interest of the measurement of the Z{sup 0} resonance parameters in the framework of the Standard Model as well as their implications for alternative models. The Standard Model predictions are described in some detail, and their precision is estimated. Then follows a brief description of the LEP collider, of the measurement of the collision energy, and of the experimental setup. A chapter is devoted to the description of the luminosity measurement, essential for the determination of total cross-sections. The measurement of the hadronic cross-section (event selection, study of backgrounds, study of sources of systematic uncertainties) is described in detail in the next chapter. Then follows a description of the method of the extraction of the resonance parameters, and a discussion of the uncertainties in their determination. The values obtained are interpreted in the framework of the Standard Model, as well as in the framework of some more general theories. Finally, the event generator for hadron production in two-photon collisions is described in the appendix. (author). 69 refs., 51 figs., 9 tabs., 1 ann.

  5. Molecular Spectroscopy With a Compact 557-GHz Heterodyne Receiver

    DEFF Research Database (Denmark)

    Neumaier, Philipp F.-X.; Richter, Heiko; Stake, Jan

    2014-01-01

    We report on a heterodyne terahertz spectrometer based on a fully integrated 557-GHz receiver and a digital fast Fourier transform spectrometer. The receiver consists of a chain of multipliers and power amplifiers, followed by a heterostructure barrier varactor tripler that subharmonically pumps...... a membrane GaAs Schottky diode mixer. All sub-components are newly developed and optimized with regard to the overall receiver performance such as noise temperature, power consumption, weight and physical size. The receiver works at room temperature, has a double sideband noise temperature as low as 2000 K...

  6. Feasibility studies for a wireless 60 GHz tracking detector readout

    International Nuclear Information System (INIS)

    Dittmeier, S.; Schöning, A.; Soltveit, H.K.; Wiedner, D.

    2016-01-01

    The amount of data produced by highly granular silicon tracking detectors in high energy physics experiments poses a major challenge to readout systems. At high collision rates, e.g. at LHC experiments, only a small fraction of data can be read out with currently used technologies. To cope with the requirements of future or upgraded experiments new data transfer techniques are required which offer high data rates at low power and low material budget. Wireless technologies operating in the 60 GHz band or at higher frequencies offer high data rates and are thus a promising upcoming alternative to conventional data transmission via electrical cables or optical fibers. Using wireless technology, the amount of cables and connectors in detectors can be significantly reduced. Tracking detectors profit most from a reduced material budget as fewer secondary particle interactions (multiple Coulomb scattering, energy loss, etc.) improve the tracking performance in general. We present feasibility studies regarding the integration of the wireless technology at 60 GHz into a silicon tracking detector. We use spare silicon strip modules of the ATLAS experiment as test samples which are measured to be opaque in the 60 GHz range. The reduction of cross talk between links and the attenuation of reflections is studied. An estimate of the maximum achievable link density is given. It is shown that wireless links can be placed as close as 2 cm next to each other for a layer distance of 10 cm by exploiting one or several of the following measures: highly directive antennas, absorbers like graphite foam, linear polarization and frequency channeling. Combining these measures, a data rate area density of up to 11 Tb/(s·m"2) seems feasible. In addition, two types of silicon sensors are tested under mm-wave irradiation in order to determine the influence of 60 GHz data transmission on the detector performance: an ATLAS silicon strip sensor module and an HV-MAPS prototype for the Mu3e

  7. Influence of 2. 45 GHz microwave radiation on enzyme activity

    Energy Technology Data Exchange (ETDEWEB)

    Galvin, M J; Parks, D L; McRee, D I

    1981-05-01

    The in vitro activity of acetylcholinesterase and creatine phosphokinase was determined during in vitro exposure to 2.45 GHz microwave radiation. The enzyme activities were examined during exposure to microwave radiation at specific absorption rates (SAR) of 1, 10, 50, and 100 mW/g. These specific absorption rates had no effect on the activity of either enzyme when the temperature of the control and exposed samples were similar. These data demonstrate that the activity of these two enzymes is not affected by microwave radiation at the SARs and frequency employed in this study.

  8. 280 GHz Gyro-BWO design study: Final report

    International Nuclear Information System (INIS)

    1988-07-01

    This report summarizes the results of a design study of a 280 GHz Gyro-BWO tunable source. The purpose of this study is to identify and propose viable design alternatives for any significant technological risk associated with building an operational BWO system. The tunable Gyro-BWO system will have three major components: a Gyro-BWO microwave tube, a superconducting magnet, and a power supply/modulator. The design tasks for this study in order of decreasing importance are: design and specification of the superconducting magnet; preliminary design and layout of a Gyro-BWO microwave tube; and specification for the power supply/modulator. 2 refs., 4 figs

  9. 60 GHz Wireless Propagation Channels: Characterization, Modeling and Evaluation

    OpenAIRE

    Gustafson, Carl

    2014-01-01

    To be able to connect wirelessly to the internet is nowadays a part of everyday life and the number of wireless devices accessing wireless networks worldwide are increasing rapidly. However, with the increasing number of wireless devices and applications and the amount available bandwidth, spectrum shortage is an issue. A promising way to increase the amount of available spectrum is to utilize frequency bands in the mm-wave range of 30-300 GHz that previously have not been used for typical co...

  10. Water vapor absorption in the atmospheric window at 239 GHz

    Science.gov (United States)

    Bauer, A.; Godon, M.; Carlier, J.; Ma, Q.

    1995-01-01

    Absolute absorption rates of pure water vapor and mixtures of water vapor and nitrogen have been measured in the atmospheric window at 239 GHz. The dependence on pressure as well as temperature has been obtained. The experimental data are compared with several theoretical or empirical models, and satisfactory agreement is obtained with the models involving a continuum; in the case of pure water vapor, the continuum contribution based upon recent theoretical developments gives good results. The temperature dependence is stronger than that proposed in a commonly used atmospheric transmission model.

  11. Amplifier Module for 260-GHz Band Using Quartz Waveguide Transitions

    Science.gov (United States)

    Padmanabhan, Sharmila; Fung, King Man; Kangaslahti, Pekka P.; Peralta, Alejandro; Soria, Mary M.; Pukala, David M.; Sin, Seth; Samoska, Lorene A.; Sarkozy, Stephen; Lai, Richard

    2012-01-01

    Packaging of MMIC LNA (monolithic microwave integrated circuit low-noise amplifier) chips at frequencies over 200 GHz has always been problematic due to the high loss in the transition between the MMIC chip and the waveguide medium in which the chip will typically be used. In addition, above 200 GHz, wire-bond inductance between the LNA and the waveguide can severely limit the RF matching and bandwidth of the final waveguide amplifier module. This work resulted in the development of a low-loss quartz waveguide transition that includes a capacitive transmission line between the MMIC and the waveguide probe element. This capacitive transmission line tunes out the wirebond inductance (where the wire-bond is required to bond between the MMIC and the probe element). This inductance can severely limit the RF matching and bandwidth of the final waveguide amplifier module. The amplifier module consists of a quartz E-plane waveguide probe transition, a short capacitive tuning element, a short wire-bond to the MMIC, and the MMIC LNA. The output structure is similar, with a short wire-bond at the output of the MMIC, a quartz E-plane waveguide probe transition, and the output waveguide. The quartz probe element is made of 3-mil quartz, which is the thinnest commercially available material. The waveguide band used is WR4, from 170 to 260 GHz. This new transition and block design is an improvement over prior art because it provides for better RF matching, and will likely yield lower loss and better noise figure. The development of high-performance, low-noise amplifiers in the 180-to- 700-GHz range has applications for future earth science and planetary instruments with low power and volume, and astrophysics array instruments for molecular spectroscopy. This frequency band, while suitable for homeland security and commercial applications (such as millimeter-wave imaging, hidden weapons detection, crowd scanning, airport security, and communications), also has applications to

  12. 24-71 GHz PCB Array for 5G ISM

    Science.gov (United States)

    Novak, Markus H.; Volakis, John L.; Miranda, Felix A.

    2017-01-01

    Millimeter-wave 5G mobile architectures need to consolidate disparate frequency bands into a single, multifunctional array. Existing arrays are either narrow-band, prohibitively expensive or cannot be scaled to these frequencies. In this paper, we present the first ultra-wideband millimeter wave array to operate across six 5G and ISM bands spanning 24-71 GHz. Importantly, the array is realized using low-cost PCB. The paper presents the design and optimized layout, and discusses fabrication and measurements.

  13. The 30/20 GHz experimental communications satellite system

    Science.gov (United States)

    Sivo, J. N.

    NASA is continuing to pursue an agressive satellite communications technology development program focused on the 30/20 GHz frequency band. A review of the program progress to date is presented. Included is a discussion of the technology program status as well as a description of the experimental system concept under study. Expected system performance characteristics together with spacecraft and payload configuration details including weight and power budget is presented. Overall program schedules of both the technology development and the flight system development are included.

  14. Design and modeling of a 17 GHz photocathode RF gun

    International Nuclear Information System (INIS)

    Lin, C.L.; Chen, S.C.; Wurtele, J.S.; Temkin, R.; Danly, B.

    1991-01-01

    The performance of a high-frequency (17 GHz), high accelerating gradient (250 MV/m) photocathode RF gun is studied with the particle-in-cell code MAGIC. For the parameter regime of interest, i.e. bunch charge smaller than 1 nC and bunch length shorter than 2 ps, space-charge forces and finite bunch length effects are less significant in determining the beam quality than nonlinear RF forces are. The cavity geometry, RF phase for photoemission, cathode size, and current density are being optimized to obtain high quality beams. Preliminary results are presented

  15. Feasibility studies for a wireless 60 GHz tracking detector readout

    Energy Technology Data Exchange (ETDEWEB)

    Dittmeier, S., E-mail: dittmeier@physi.uni-heidelberg.de; Schöning, A.; Soltveit, H.K.; Wiedner, D.

    2016-09-11

    The amount of data produced by highly granular silicon tracking detectors in high energy physics experiments poses a major challenge to readout systems. At high collision rates, e.g. at LHC experiments, only a small fraction of data can be read out with currently used technologies. To cope with the requirements of future or upgraded experiments new data transfer techniques are required which offer high data rates at low power and low material budget. Wireless technologies operating in the 60 GHz band or at higher frequencies offer high data rates and are thus a promising upcoming alternative to conventional data transmission via electrical cables or optical fibers. Using wireless technology, the amount of cables and connectors in detectors can be significantly reduced. Tracking detectors profit most from a reduced material budget as fewer secondary particle interactions (multiple Coulomb scattering, energy loss, etc.) improve the tracking performance in general. We present feasibility studies regarding the integration of the wireless technology at 60 GHz into a silicon tracking detector. We use spare silicon strip modules of the ATLAS experiment as test samples which are measured to be opaque in the 60 GHz range. The reduction of cross talk between links and the attenuation of reflections is studied. An estimate of the maximum achievable link density is given. It is shown that wireless links can be placed as close as 2 cm next to each other for a layer distance of 10 cm by exploiting one or several of the following measures: highly directive antennas, absorbers like graphite foam, linear polarization and frequency channeling. Combining these measures, a data rate area density of up to 11 Tb/(s·m{sup 2}) seems feasible. In addition, two types of silicon sensors are tested under mm-wave irradiation in order to determine the influence of 60 GHz data transmission on the detector performance: an ATLAS silicon strip sensor module and an HV-MAPS prototype for the Mu3e

  16. High power testing of a 17 GHz photocathode RF gun

    International Nuclear Information System (INIS)

    Chen, S.C.; Danly, B.G.; Gonichon, J.

    1995-01-01

    The physics and technological issues involved in high gradient particle acceleration at high microwave (RF) frequencies are under study at MIT. The 17 GHz photocathode RF gun has a 1 1/2 cell (π mode) room temperature cooper cavity. High power tests have been conducted at 5-10 MW levels with 100 ns pulses. A maximum surface electric field of 250 MV/m was achieved. This corresponds to an average on-axis gradient of 150 MeV/m. The gradient was also verified by a preliminary electron beam energy measurement. Even high gradients are expected in our next cavity design

  17. A 30 GHz 5-TeV Linear Collider

    International Nuclear Information System (INIS)

    Wilson, Perry B

    2003-01-01

    We present parameters for a linear collider with a 3 to 5 TeV center-of-mass energy that utilizes conventional rf technology operating at a frequency around 30 GHz. We discuss the scaling laws and assumed limitations that lead to the parameters described and we compare the merits and liabilities of different technological options including rf power source, accelerator structure, and final focus system design. Finally, we outline the components of the collider while specifying the required alignment and construction tolerances

  18. Transmission Line for 258 GHz Gyrotron DNP Spectrometry

    Science.gov (United States)

    Bogdashov, Alexandr A.; Belousov, Vladimir I.; Chirkov, Alexey V.; Denisov, Gregory G.; Korchagin, Vyacheslav V.; Kornishin, Sergey Yu.; Tai, Evgeny M.

    2011-06-01

    We describe the design and test results of the transmission line for liquid-state (LS) and solid-state (SS) DNP spectrometers with the second-harmonic 258.6 GHz gyrotron at the Institute of the Biophysical Chemistry Center of Goethe University (Frankfurt). The 13-meter line includes a mode converter, HE11 waveguides, 4 mitre bends, a variable polarizer-attenuator, directional couplers, a water-flow calorimeter and a mechanical switch. A microwave power of about 15 W was obtained in the pure HE11 mode at the spectrometer inputs.

  19. External Validation of a Case-Mix Adjustment Model for the Standardized Reporting of 30-Day Stroke Mortality Rates in China.

    Science.gov (United States)

    Yu, Ping; Pan, Yuesong; Wang, Yongjun; Wang, Xianwei; Liu, Liping; Ji, Ruijun; Meng, Xia; Jing, Jing; Tong, Xu; Guo, Li; Wang, Yilong

    2016-01-01

    A case-mix adjustment model has been developed and externally validated, demonstrating promise. However, the model has not been thoroughly tested among populations in China. In our study, we evaluated the performance of the model in Chinese patients with acute stroke. The case-mix adjustment model A includes items on age, presence of atrial fibrillation on admission, National Institutes of Health Stroke Severity Scale (NIHSS) score on admission, and stroke type. Model B is similar to Model A but includes only the consciousness component of the NIHSS score. Both model A and B were evaluated to predict 30-day mortality rates in 13,948 patients with acute stroke from the China National Stroke Registry. The discrimination of the models was quantified by c-statistic. Calibration was assessed using Pearson's correlation coefficient. The c-statistic of model A in our external validation cohort was 0.80 (95% confidence interval, 0.79-0.82), and the c-statistic of model B was 0.82 (95% confidence interval, 0.81-0.84). Excellent calibration was reported in the two models with Pearson's correlation coefficient (0.892 for model A, pcase-mix adjustment model could be used to effectively predict 30-day mortality rates in Chinese patients with acute stroke.

  20. Isolation of verbascoside and validation of method to standardize the crude extract of the aerial parts of Buddleja stachyoides Cham. and Schltdl. (Scrophulariaceae)

    International Nuclear Information System (INIS)

    Oliveira, Daniella M.S. de; Miguel, Marilis D.; Kalegari, Milena; Miguel, Obdulio G.; Moreira, Thais F.

    2014-01-01

    Phenylpropanoid glycoside verbascoside was isolated and identified from the ethyl acetate fraction of the aerial parts of Buddleja stachyoides Cham. and Schltdl. by 1 H-NMR. A method using high-performance liquid chromatography has been developed and validated for determination of verbascoside in alcoholic crude extract of the aerial parts of B. stachyoides. Analysis was performed on a Phenomenex® Gemini-NX C18 analytical column (250 mm × 4.6 mm; 5 μm) using a mobile phase (pump A - aqueous solution containing H 2 SO 4 (0.01 M), H 3 PO 4 (0.4%), and (C 2 H 5 ) 2 NH (0.4%); pump B - methanol:aqueous (95:5) solution containing H 2 SO 4 (0.05 M), H 3 PO 4 (2%), and (C 2 H 5 ) 2 NH (0.2%); pump C - acetonitrile:aqueous (90:10) solution containing H 2 SO 4 (0.05 M) and H 3 PO 4 (2%)) and a diode array detector at 325 nm. The method was validated in accordance with ANVISA guidelines and may be applied to quality control of herbal medicine with aerial parts of B. stachyoides. (author)

  1. External Validation of a Case-Mix Adjustment Model for the Standardized Reporting of 30-Day Stroke Mortality Rates in China.

    Directory of Open Access Journals (Sweden)

    Ping Yu

    Full Text Available A case-mix adjustment model has been developed and externally validated, demonstrating promise. However, the model has not been thoroughly tested among populations in China. In our study, we evaluated the performance of the model in Chinese patients with acute stroke.The case-mix adjustment model A includes items on age, presence of atrial fibrillation on admission, National Institutes of Health Stroke Severity Scale (NIHSS score on admission, and stroke type. Model B is similar to Model A but includes only the consciousness component of the NIHSS score. Both model A and B were evaluated to predict 30-day mortality rates in 13,948 patients with acute stroke from the China National Stroke Registry. The discrimination of the models was quantified by c-statistic. Calibration was assessed using Pearson's correlation coefficient.The c-statistic of model A in our external validation cohort was 0.80 (95% confidence interval, 0.79-0.82, and the c-statistic of model B was 0.82 (95% confidence interval, 0.81-0.84. Excellent calibration was reported in the two models with Pearson's correlation coefficient (0.892 for model A, p<0.001; 0.927 for model B, p = 0.008.The case-mix adjustment model could be used to effectively predict 30-day mortality rates in Chinese patients with acute stroke.

  2. A formula for human average whole-body SARwb under diffuse fields exposure in the GHz region

    International Nuclear Information System (INIS)

    Bamba, A; Joseph, W; Vermeeren, G; Thielens, A; Tanghe, E; Martens, L

    2014-01-01

    A simple formula to determine the human average whole-body SAR (SAR wb ) under realistic propagation conditions is proposed in the GHz region, i.e. from 1.45 GHz to 5.8 GHz. The methodology is based on simulations of ellipsoidal human body models. Only the exposure (incident power densities) and the human mass are needed to apply the formula. Diffuse scattered illumination is addressed for the first time and the possible presence of a Line-of-Sight (LOS) component is addressed as well. As validation, the formula is applied to calculate the average whole-body SAR wb in 3D heterogeneous phantoms, i.e. the virtual family (34 year-old male, 26 year-old female, 11 year-old girl, and 6 year-old boy) and the results are compared with numerical ones—using the Finite-Difference Time-Domain (FDTD) method—at 3 GHz. For the LOS exposure, the average relative error varies from 28% to 12% (resp. 14–12%) for the vertical polarization (resp. horizontal polarization), depending on the heteregeneous phantom. Regarding the diffuse illumination, relative errors of −39.40%, −11.70%, 10.70%, and 10.60% are obtained for the 6 year-old boy, 11 year-old girl, 26 year-old female, and 34 year-old male, respectively. The proposed formula estimates well (especially for adults) the SAR wb induced by diffuse illumination in realistic conditions. In general, the correctness of the formula improves when the human mass increases. Keeping the uncertainties of the FDTD simulations in mind, the proposed formula might be important for the dosimetry community to assess rapidly and accurately the human absorption of electromagnetic radiation caused by diffuse fields in the GHz region. Finally, we show the applicability of the proposed formula to personal dosimetry for epidemiological research. (paper)

  3. Study of verification and validation of standard welding procedure specifications guidelines for API 5L X-70 grade line pipe welding

    Directory of Open Access Journals (Sweden)

    Qazi H. A. A.

    2017-12-01

    Full Text Available Verification and validation of welding procedure specifications for X-70 grade line pipe welding was performed as per clause 8.2, Annexure B and D of API 5L, 45th Edition to check weld integrity in its future application conditions. Hot rolled coils were imported from China, de-coiling, strip edge milling, three roller bending to from pipe, inside and outside submerged arc welding of pipe, online ultrasonic testing of weld, HAZ and pipe body, cutting at fixed random length of pipe, visual inspection of pipe, Fluoroscopic inspection of pipe, welding procedure qualification test pieces marking at weld portion of the pipe, tensile testing, guided bend testing, CVN Impact testing were performed. Detailed study was conducted to explore possible explanations and variation in mechanical properties, WPS is examined and qualified as per API 5L 45th Edition.

  4. Validation of a method to the addition the multiple standard in the analysis of Pb in reservoir waters for atomic absorption spectrometric

    International Nuclear Information System (INIS)

    Mayari, R.; Espinosa, M.C.; Vazques, J.

    2003-01-01

    The evaluation of a method is presented for the analysis of Pb in reservoir waters for atomic spectrometric with direct aspiration. For the validation of the analytic method a level of concentration of 0.05 mg/L was evaluated. The precision of the method was of 9.97% and the bias was 0.6% 8 samples of surface waters they were collected and of bottom of the tributaries of the reservoir Scorpions and the stocking of the concentrations in the tributaries was from 0,052 + - 0.026 inferior mg/L to the established one in the Cuban norm of evaluation of the hydirc objects of fishing use

  5. Reliable categorisation of visual scoring of coronary artery calcification on low-dose CT for lung cancer screening: validation with the standard Agatston score

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Yi-Luan; Wu, Fu-Zong; Wang, Yen-Chi [Kaohsiung Veterans General Hospital, Department of Radiology, Kaohsiung 813 (China); National Yang Ming University, Faculty of Medicine, School of Medicine, Taipei (China); Ju, Yu-Jeng [National Taiwan University, Department of Psychology, Taipei (China); Mar, Guang-Yuan [Kaohsiung Veterans General Hospital, Division of Cardiology, Department of Medicine, Kaohsiung 813 (China); Chuo, Chiung-Chen [Kaohsiung Veterans General Hospital, Department of Radiology, Kaohsiung 813 (China); Lin, Huey-Shyan [Fooyin University, School of Nursing, Kaohsiung (China); Wu, Ming-Ting [Kaohsiung Veterans General Hospital, Department of Radiology, Kaohsiung 813 (China); National Yang Ming University, Faculty of Medicine, School of Medicine, Taipei (China); National Yang Ming University, Institute of Clinical Medicine, Taipei (China)

    2013-05-15

    To validate the reliability of the visual coronary artery calcification score (VCACS) on low-dose CT (LDCT) for concurrent screening of CAC and lung cancer. We enrolled 401 subjects receiving LDCT for lung cancer screening and ECG-gated CT for the Agatston score (AS). LDCT was reconstructed with 3- and 5-mm slice thickness (LDCT-3mm and LDCT-5mm respectively) for VCACS to obtain VCACS-3mm and VCACS-5mm respectively. After a training session comprising 32 cases, two observers performed four-scale VCACS (absent, mild, moderate, severe) of 369 data sets independently, the results were compared with four-scale AS (0, 1-100, 101-400, >400). CACs were present in 39.6 % (146/369) of subjects. The sensitivity of VCACS-3mm was higher than for VCACS-5mm (83.6 % versus 74.0 %). The median of AS of the 24 false-negative cases in VCACS-3mm was 2.3 (range 1.1-21.1). The false-negative rate for detecting AS {>=} 10 on LDCT-3mm was 1.9 %. VCACS-3mm had higher concordance with AS than VCACS-5mm (k = 0.813 versus k = 0.685). An extended test of VCACS-3mm for four junior observers showed high inter-observer reliability (intra-class correlation = 0.90) and good concordance with AS (k = 0.662-0.747). This study validated the reliability of VCACS on LDCT for lung cancer screening and showed that LDCT-3mm was more feasible than LDCT-5mm for CAD risk stratification. (orig.)

  6. Initial tests of an 11.4 GHz magnicon amplifier

    International Nuclear Information System (INIS)

    Gold, S.H.; Sullivan, C.A.; Manheimer, W.M.; Hafizi, B.

    1994-01-01

    The magnicon, a scanning beam microwave amplifier related to the gyrocon, is a possible replacement for klystron amplifiers in future high-gradient linear accelerators. The magnicon circuit consists of a multicavity deflection system followed by an output cavity. The purpose of the deflection system is to spin up the electron beam phase-coherently to high transverse momentum. In order to do this, the deflection cavities employ rotating TM 11 modes, producing a gyrating electron beam whose centroid rotates about the cavity axis in synchronism with the advance in phase of the rf modes. The output cavity employs a cyclotron resonant mechanism to extract principally the transverse beam momentum. It employs an rf mode that rotates synchronously with the deflection cavity modes, and with the entry point of the electron beam into the output cavity, making possible a highly efficient interaction. The NRL magnicon uses a 100--200 A, 500 keV beam produced by a cold-cathode diode on the NRL Long-Pulse Accelerator Facility. The first cavity is externally driven at 5.7 GHz, while the output cavity is designed to produce megawatts of power at 11.4 GHz in the TM 210 mode. In this paper, the authors present a progress report on the NRL magnicon experiment. They will discuss the procedure used to cold test and calibrate the magnicon circuit, and present initial results from experimental operations

  7. A mechanism for tuning 5 GHz HTS filters

    Energy Technology Data Exchange (ETDEWEB)

    Ohsaka, M.; Takeuchi, S.; Ono, S.; Lee, J.H.; Saito, A. [Department of Electrical Engineering, Yamagata University, 4-3-16 Johnan, Yonezawa 992-8510 (Japan); Akasegawa, A.; Yamanaka, K.; Kurihara, K. [Fujitsu LTD., 10-1 Wakamiya, Morinosato, Atsugi, Kanagawa 243-0197 (Japan); Ohshima, S. [Department of Electrical Engineering, Yamagata University, 4-3-16 Johnan, Yonezawa 992-8510 (Japan)], E-mail: ohshima@yz.yamagata-u.ac.jp

    2008-09-15

    We developed a tuning mechanism of HTS filter with a dielectric tuning plate, dielectric trimming rods, and conducting trimming rods. The tuning plate has windows through which the dielectric and conducting trimming rods pass. The tuning plate was designed for a 3-pole filter with 5 GHz center frequency (f{sub c}) and 100 MHz bandwidth (BW) using a 3-dimensional electromagnetic simulator. We were able to shift the f{sub c} to frequencies below 500 MHz using the tuning plate with a dielectric constant of 45. However, the insertion loss (IL) and the pass-band ripple of the filter became more severe and the BW of the filter was narrower after tuning. We tried to improve the filter properties after tuning using the dielectric and conducting trimming rods. We decreased the IL and the pass-band ripple by adjusting the height of the dielectric trimming rods to above the resonators. Also, the BW was improved by using copper (Cu) trimming rods above the spaces between the resonators. The tuning plate and the trimming rods did not affect the IL. So, we simulated 500 MHz tuning without the filter properties deteriorating at f{sub c} = 5 GHz. Also, we experimentally evaluated that the f{sub c} could be shifted to 340 MHz using the dielectric plate, the pass-band ripple could be decreased by ripple trimming using the dielectric rods, and the BW could be increased 31 MHz by BW trimming using the Cu rods.

  8. Test results from the LLNL 250 GHz CARM experiment

    International Nuclear Information System (INIS)

    Kulke, B.; Caplan, M.; Bubp, D.; Houck, T.; Rogers, D.; Trimble, D.; VanMaren, R.; Westenskow, G.; McDermott, D.B.; Luhmann, N.C. Jr.; Danly, B.

    1991-01-01

    The authors have completed the initial phase of a 250 GHz CARM experiment, driven by the 2 MeV, 1 kA, 30 ns induction linac at the LLNL ARC facility. A non-Brillouin, solid, electron beam is generated from a flux-threaded, thermionic cathode. As the beam traverses a 10 kG plateau produced by a superconducting magnet, ten percent of the beam energy is converted into rotational energy in a bifilar helix wiggler that produces a spiraling, 50 G, transverse magnetic field. The beam is then compressed to a 5 mm diameter as it drifts into a 30 kG plateau. For the present experiment, the CARM interaction region consisted of a single Bragg section resonator, followed by a smooth-bore amplifier section. Using high-pass filters, they have observed broadband output signals estimated to be at the several megawatt level in the range 140 to over 230 GHz. This is consistent with operation as a superradiant amplifier. Simultaneously, they also observed K a band power levels near 3 MW

  9. Prospect for a 60 GHz multicharged ECR ion source

    Science.gov (United States)

    Thuillier, T.; Bondoux, D.; Angot, J.; Baylac, M.; Froidefond, E.; Jacob, J.; Lamy, T.; Leduc, A.; Sole, P.; Debray, F.; Trophime, C.; Skalyga, V.; Izotov, I.

    2018-05-01

    The conceptual design of a fourth generation hybrid electron cyclotron resonance (ECR) ion source operated at 60 GHz is proposed. The axial magnetic mirror is generated with a set of three Nb3Sn coils, while the hexapole is made with room temperature (RT) copper coils. The motivations for such a hybrid development are to study further the ECR plasma physics and the intense multicharged ion beams' production and transport at a time when a superconducting (SC) hexapole appears unrealistic at 60 GHz. The RT hexapole coil designed is an evolution of the polyhelix technology developed at the French High Magnetic Field Facility. The axial magnetic field is generated by means of 3 Nb3Sn SC coils operated with a maximum current density of 350 A/mm2 and a maximum coil load line factor of 81%. The ECR plasma chamber resulting from the design features an inner radius of 94 mm and a length of 500 mm. The radial magnetic intensity is 4.1 T at the wall. Characteristic axial mirror peaks are 8 and 4.5 T, with 1.45 T minimum in between.

  10. Test results from the LLNL 250 GHz CARM experiment

    International Nuclear Information System (INIS)

    Kulke, B.; Caplan, M.; Bubp, D.; Houck, T.; Rogers, D.; Trimble, D.; VanMaren, R.; Westenskow, G.; McDermott, D.B.; Luhmann, N.C. Jr.; Danly, B.

    1991-05-01

    We have completed the initial phase of a 250 GHz CARM experiment, driven by the 2 MeV, 1 kA, 30 ns induction linac at the LLNL ARC facility. A non-Brillouin, solid, electron beam is generated from a flux-threaded, thermionic cathode. As the beam traverses a 10 kG plateau produced by a superconducting magnet, ten percent of the beam energy is converted into rotational energy in a bifilar helix wiggler that produces a spiraling, 50 G, transverse magnetic field. The beam is then compressed to a 5 mm diameter as it drifts into a 30 kG plateau. For the present experiment, the CARM interaction region consisted of a single Bragg section resonator, followed by a smooth-bore amplifier section. Using high-pass filters, we have observed broadband output signals estimated to be at the several megawatt level in the range 140 to over 230 GHz. This is consistent with operation as a superradiant amplifier. Simultaneously, we also observed K a band power levels near 3 MW

  11. ATLAS 10 GHz electron cyclotron resonance ion source upgrade project

    CERN Document Server

    Moehs, D P; Pardo, R C; Xie, D

    2000-01-01

    A major upgrade of the first ATLAS 10 GHz electron cyclotron resonance (ECR) ion source, which began operations in 1987, is in the planning and procurement phase. The new design will convert the old two-stage source into a single-stage source with an electron donor disk and high gradient magnetic field that preserves radial access for solid material feeds and pumping of the plasma chamber. The new magnetic-field profile allows for the possibility of a second ECR zone at a frequency of 14 GHz. An open hexapole configuration, using a high-energy-product Nd-Fe-B magnet material, having an inner diameter of 8.8 cm and pole gaps of 2.4 cm, has been adopted. Models indicate that the field strengths at the chamber wall, 4 cm in radius, will be 9.3 kG along the magnet poles and 5.6 kG along the pole gaps. The individual magnet bars will be housed in austenitic stainless steel, allowing the magnet housing within the aluminum plasma chamber to be used as a water channel for direct cooling of the magnets. Eight solenoid...

  12. Observation of 45 GHz current waveforms using HTS sampler

    International Nuclear Information System (INIS)

    Maruyama, M.; Suzuki, H.; Hato, T.; Wakana, H.; Nakayama, K.; Ishimaru, Y.; Horibe, O.; Adachi, S.; Kamitani, A.; Suzuki, K.; Oshikubo, Y.; Tarutani, Y.; Tanabe, K.

    2005-01-01

    We succeeded in observing high-frequency current waveforms up to 45 GHz using a high-temperature superconducting (HTS) sampler. In this experiment, we used a sampler circuit with a superconducting pickup coil, which magnetically detects current signals flowing through a micro-strip line on a printed board placed outside the cryochamber. This type of measurement enables non-contact current-waveform observation that seems useful for analyses of EMI, defects in LSI, etc. Computer simulation reveals that one of our latest versions of HTS sampler circuits having Josephson transmission lines with optimized biases as buffers has a potential of sampling high-frequency signals with a bandwidth above 100 GHz. To realize the circuit parameters required in the simulations, we developed an HTS circuit fabrication process employing a lower ground plane structure with SrSnO 3 insulating layers. We consider that improvement of the circuit fabrication process and optimization of the pickup coil lead to much higher signal frequency observable by the sampler

  13. Estimates of primary productivity over the Thar Desert based upon Nimbus-7 37 GHz data - 1979-1985

    Science.gov (United States)

    Choudhury, B. J.

    1987-01-01

    An empirical relationship has been determined between the difference of vertically and horizontally polarized brightness temperatures noted at the 37 GHz frequency of the Nimbus-7 SMMR and primary productivity over hot arid and semiarid regions of Africa and Australia. This empirical relationship is applied to estimate the primary productivity over the Thar Desert between 1979 and 1985, giving an average value of 0.271 kg/sq m per yr. The spatial variability of the productivity values is found to be quite significant, with a standard deviation about the mean of 0.08 kg/sq m per yr.

  14. Spatial and Temporal Characterization of Indoor Millimeter Wave Propagation at 24 GHz

    Directory of Open Access Journals (Sweden)

    Seok-hwan Min

    2016-01-01

    Full Text Available Indoor millimeter wave propagation at the frequency of 24 GHz is studied by experimental methods. Measurements are performed to obtain temporal and spatial channel model using a channel sounder and rotating antennas in a corridor. The measured impulse responses are processed to obtain compact channel model following Saleh-Valenzuela’s model. The responses are compared with those of 5.3 GHz for the same test sites. Angular spread of 24 GHz is found to be smaller than that of 5.3 GHz, while echoes of 24 GHz are found to be longer than those of 5.3 GHz.

  15. A High Voltage Swing 1.9 GHz PA in Standard CMOS

    NARCIS (Netherlands)

    Aartsen, W.A.J.; Annema, Anne J.; Nauta, Bram

    2002-01-01

    A circuit technique for RF power amplifiers that reliably handle voltage peaks well above the nominal supply voltage is presented. To achieve this high-voltage tolerance the circuit implements switched-cascode transistors that yield reliable operation for voltages up to 7V at RF frequencies in a

  16. Electron-beam buncher to operate over the frequency range 1-4 GHz

    International Nuclear Information System (INIS)

    Goldberg, D.A.; Arthur, A.A.; Flood, W.S.; Voelker, F.

    1983-03-01

    We present a description of an electron buncher to be installed in the terminal of a Van de Graaff, which is to produce a modulated beam over the frequency range 1-4 GHz. The modulator geometry has been optimized so that the modulation amplitude should be nearly constant over the frequency ranges 1-2 GHz and 2-4 GHz. Preliminary results indicate the device works as predicted

  17. A 1.8 GHz Voltage-Controlled Oscillator using CMOS Technology

    Science.gov (United States)

    Maisurah, M. H. Siti; Emran, F. Nazif; Norman Fadhil, Idham M.; Rahim, A. I. Abdul; Razman, Y. Mohamed

    2011-05-01

    A Voltage-Controlled Oscillator (VCO) for 1.8 GHz application has been designed using a combination of both 0.13 μm and 0.35 μm CMOS technology. The VCO has a large tuning range, which is from 1.39 GHz to 1.91 GHz, using a control voltage from 0 to 3V. The VCO exhibits a low phase-noise at 1.8 GHz which is around -119.8dBc/Hz at a frequency offset of 1 MHz.

  18. Validation of a reversed-phase high-performance liquid chromatographic method for the determination of free amino acids in rice using l-theanine as the internal standard.

    Science.gov (United States)

    Liyanaarachchi, G V V; Mahanama, K R R; Somasiri, H P P S; Punyasiri, P A N

    2018-02-01

    The study presents the validation results of the method carried out for analysis of free amino acids (FAAs) in rice using l-theanine as the internal standard (IS) with o-phthalaldehyde (OPA) reagent using high-performance liquid chromatography-fluorescence detection. The detection and quantification limits of the method were in the range 2-16μmol/kg and 3-19μmol/kg respectively. The method had a wide working range from 25 to 600μmol/kg for each individual amino acid, and good linearity with regression coefficients greater than 0.999. Precision measured in terms of repeatability and reproducibility, expressed as percentage relative standard deviation (% RSD) was below 9% for all the amino acids analyzed. The recoveries obtained after fortification at three concentration levels were in the range 75-105%. In comparison to l-norvaline, findings revealed that l-theanine is suitable as an IS and the validated method can be used for FAA determination in rice. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Mobile gait analysis via eSHOEs instrumented shoe insoles: a pilot study for validation against the gold standard GAITRite®.

    Science.gov (United States)

    Jagos, Harald; Pils, Katharina; Haller, Michael; Wassermann, Claudia; Chhatwal, Christa; Rafolt, Dietmar; Rattay, Frank

    2017-07-01

    Clinical gait analysis contributes massively to rehabilitation support and improvement of in-patient care. The research project eSHOE aspires to be a useful addition to the rich variety of gait analysis systems. It was designed to fill the gap of affordable, reasonably accurate and highly mobile measurement devices. With the overall goal of enabling individual home-based monitoring and training for people suffering from chronic diseases, affecting the locomotor system. Motion and pressure sensors gather movement data directly on the (users) feet, store them locally and/or transmit them wirelessly to a PC. A combination of pattern recognition and feature extraction algorithms translates the motion data into standard gait parameters. Accuracy of eSHOE were evaluated against the reference system GAITRite in a clinical pilot study. Eleven hip fracture patients (78.4 ± 7.7 years) and twelve healthy subjects (40.8 ± 9.1 years) were included in these trials. All subjects performed three measurements at a comfortable walking speed over 8 m, including the 6-m long GAITRite mat. Six standard gait parameters were extracted from a total of 347 gait cycles. Agreement was analysed via scatterplots, histograms and Bland-Altman plots. In the patient group, the average differences between eSHOE and GAITRite range from -0.046 to 0.045 s and in the healthy group from -0.029 to 0.029 s. Therefore, it can be concluded that eSHOE delivers adequately accurate results. Especially with the prospect as an at home supplement or follow-up to clinical gait analysis and compared to other state of the art wearable motion analysis systems.

  20. Validation of different measures of insulin sensitivity of glucose metabolism in dairy cows using the hyperinsulinemic euglycemic clamp test as the gold standard.

    Science.gov (United States)

    De Koster, J; Hostens, M; Hermans, K; Van den Broeck, W; Opsomer, G

    2016-10-01

    The aim of the present research was to compare different measures of insulin sensitivity in dairy cows at the end of the dry period. To do so, 10 clinically healthy dairy cows with a varying body condition score were selected. By performing hyperinsulinemic euglycemic clamp (HEC) tests, we previously demonstrated a negative association between the insulin sensitivity and insulin responsiveness of glucose metabolism and the body condition score of these animals. In the same animals, other measures of insulin sensitivity were determined and the correlation with the HEC test, which is considered as the gold standard, was calculated. Measures derived from the intravenous glucose tolerance test (IVGTT) are based on the disappearance of glucose after an intravenous glucose bolus. Glucose concentrations during the IVGTT were used to calculate the area under the curve of glucose and the clearance rate of glucose. In addition, glucose and insulin data from the IVGTT were fitted in the minimal model to derive the insulin sensitivity parameter, Si. Based on blood samples taken before the start of the IVGTT, basal concentrations of glucose, insulin, NEFA, and β-hydroxybutyrate were determined and used to calculate surrogate indices for insulin sensitivity, such as the homeostasis model of insulin resistance, the quantitative insulin sensitivity check index, the revised quantitative insulin sensitivity check index and the revised quantitative insulin sensitivity check index including β-hydroxybutyrate. Correlation analysis revealed no association between the results obtained by the HEC test and any of the surrogate indices for insulin sensitivity. For the measures derived from the IVGTT, the area under the curve for the first 60 min of the test and the Si derived from the minimal model demonstrated good correlation with the gold standard. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Validation of spectroscopic gas analyzer accuracy using gravimetric standard gas mixtures: impact of background gas composition on CO2 quantitation by cavity ring-down spectroscopy

    Science.gov (United States)

    Lim, Jeong Sik; Park, Miyeon; Lee, Jinbok; Lee, Jeongsoon

    2017-12-01

    The effect of background gas composition on the measurement of CO2 levels was investigated by wavelength-scanned cavity ring-down spectrometry (WS-CRDS) employing a spectral line centered at the R(1) of the (3 00 1)III ← (0 0 0) band. For this purpose, eight cylinders with various gas compositions were gravimetrically and volumetrically prepared within 2σ = 0.1 %, and these gas mixtures were introduced into the WS-CRDS analyzer calibrated against standards of ambient air composition. Depending on the gas composition, deviations between CRDS-determined and gravimetrically (or volumetrically) assigned CO2 concentrations ranged from -9.77 to 5.36 µmol mol-1, e.g., excess N2 exhibited a negative deviation, whereas excess Ar showed a positive one. The total pressure broadening coefficients (TPBCs) obtained from the composition of N2, O2, and Ar thoroughly corrected the deviations up to -0.5 to 0.6 µmol mol-1, while these values were -0.43 to 1.43 µmol mol-1 considering PBCs induced by only N2. The use of TPBC enhanced deviations to be corrected to ˜ 0.15 %. Furthermore, the above correction linearly shifted CRDS responses for a large extent of TPBCs ranging from 0.065 to 0.081 cm-1 atm-1. Thus, accurate measurements using optical intensity-based techniques such as WS-CRDS require TPBC-based instrument calibration or use standards prepared in the same background composition of ambient air.

  2. Use of the 37-38 GHz and 40-40.5 GHz Ka-bands for Deep Space Communications

    Science.gov (United States)

    Morabito, David; Hastrup, Rolf

    2004-01-01

    This paper covers a wide variety of issues associated with the implementation and use of these frequency bands for deep space communications. Performance issues, such as ground station pointing stability, ground antenna gain, antenna pattern, and propagation effects such as due to atmospheric, charged-particle and space loss at 37 GHz, will be addressed in comparison to the 32 GHz Ka-band deep space allocation. Issues with the use of and competition for this spectrum also will be covered. The state of the hardware developed (or proposed) for operating in this frequency band will be covered from the standpoint of the prospects for achieving higher data rates that could be accommodated in the available bandwidth. Hardware areas to be explored include modulators, digital-to-analog converters, filters, power amplifiers, receivers, and antennas. The potential users of the frequency band will be explored as well as their anticipated methods to achieve the potential high data rates and the implications of the competition for bandwidth.

  3. AASM standards of practice compliant validation of actigraphic sleep analysis from SOMNOwatch(TM) versus polysomnographic sleep diagnostics shows high conformity also among subjects with sleep disordered breathing

    International Nuclear Information System (INIS)

    Dick, R; Schulz, J; Penzel, T; Fietze, I; Partinen, M; Hein, H

    2010-01-01

    In recent AASM practice, parameter actimetry is cited to measure total sleep time in obstructive sleep apnoea patients, when polysomnography is not available. An actigraph was therefore compared to polysomnographic data in 28 subjects with known sleep disordered breathing. Total sleep time (TST), sleep period time (SPT), sleep efficiency (SE), sustained sleep efficiency (SSE), sleep onset latency (SL) and sleep/wake pattern were compared to gold standard polysomnography. The results of an epoch-by-epoch comparison of sleep/wake from actigraphy to sleep stages from polysomnography gave a sensitivity of 90.2%, a specificity of 95.2% and an overall accuracy of 85.9%. Correlations were moderately strong for SE (0.71, p < 0.001) and SSE (0.65, p < 0.001) and high for TST (0.89, p < 0.001), SPT (0.91, p < 0.001) and SL (0.89, p < 0.001). It was concluded that actigraphy is not identical with PSG recording but gives good results in sleep/wake patterns and predicting TST, SPT, SSE, SE and SL also in sleep apnoea patients not suffering from other sleep disorders. The difficult detection of correct sleep onset causes SSE and SL to be less predictable. Therefore a 15-epoch criterion was introduced and resulted in high correlation of 0.89 for sleep latency, but has to be tested on a bigger population

  4. 10 GHz microstrip spanar antennas: an experimental analysis

    International Nuclear Information System (INIS)

    Othman, Mohd Azlishah; Azman, Hazwani; Husain, Mohd Nor; Aziz, Mohamad Zoinol Abidin Abd; Rahim, Yahaya Abd; Pee, Ahmad Nairn Che; Motsidi, Mohamad Radzi; Othman, Mohd Fairuz Iskandar

    2014-01-01

    This paper presents Spanar Antenna designed using CST Microwave Studio Simulation 2011. The proposed antenna was designed to operate at 10 GHz, which suggested return loss, S 11 must be less than -10 dB and voltage standing wave ratio (VSWR) must be less than 2. The best performance of simulation of Spanar Antenna was obtained at a small size of 24.8 mm × 8.0 mm with dimension board of FR4 substrate 31.7 mm × 18.5 mm. The thickness (h) and dielectric constant (εr) of substrate were 1.6 mm and 4.7. An analysis between simulation result and measurement result has been compared in order to see the antenna performance.

  5. Array of 1- to 2-GHz electrodes for stochastic cooling

    International Nuclear Information System (INIS)

    Voelker, F.; Henderson, T.; Johnson, J.

    1983-03-01

    Described is an array of directional-coupler loop pairs that are to be used as either pickup or kicker electrodes for the frequency range of 1 to 2 GHz. Each coupler pair is a lambda/4 long parallel-plane transmission line that is arranged to be flush with the upper and lower surfaces of a rectangular beam pipe. As pickups, the coupler pairs are used in arrays and are operated at 80 degrees Kelvin for improving the signal-to-noise ratio. The loop output power is added in stripline combiner networks before being fed to a low-noise preamplifier. When the couplers are used as kickers, the combining network serves to split power and distribute it uniformly to each electrode

  6. Experiments on a 14.5 GHz ECR source

    International Nuclear Information System (INIS)

    Hill, C.E.; Langbein, K.

    1996-01-01

    The 14.5 GHz ECR4 source supplied to CERN in the framework of the Heavy Ion Facility collaboration provided Pb 27+ operational beams to a new custom built linac in 1994. This source, which operates in the pulsed 'afterglow' mode, quickly met its design specification of 80 eμA and now provides currents >100 eμA regularly. Early source tests showed the existence of extremely stable modes of operation. In the search for higher intensities a number of experiments have been performed on plasma gas composition, RF power matching, extraction, beam pulse compression and a biased dynode. The results of these tests will be presented along with further ideas to improve source performance. (author)

  7. Feasibility studies for a wireless 60 GHz tracking detector readout

    CERN Document Server

    Dittmeier, Sebastian; Soltveit, Hans Kristian; Wiedner, Dirk

    2016-01-01

    The amount of data produced by highly granular silicon tracking detectors in high energy physics experiments poses a major challenge to readout systems. At high collision rates, e.g. at LHC experiments, only a small fraction of data can be read out with currently used technologies. To cope with the requirements of future or upgraded experiments new data transfer techniques are required which offer high data rates at low power and low material budget. Wireless technologies operating in the 60 GHz band or at higher frequencies offer high data rates and are thus a promising upcoming alternative to conventional data transmission via electrical cables or optical fibers. Using wireless technology, the amount of cables and connectors in detectors can be significantly reduced. Tracking detectors profit most from a reduced material budget as fewer secondary particle interactions (multiple Coulomb scattering, energy loss, etc.) improve the tracking performance in general. We present feasibility studies regarding the in...

  8. Analysis of parasitic oscillations in 42 GHz gyrotron beam tunnel

    Science.gov (United States)

    Kumar, N.; Singh, U.; Singh, T. P.; Sinha, A. K.

    2011-02-01

    Parasitic oscillation excitation analysis has been carried out for the 42 GHz gyrotron beam tunnel. This article presents a systematic approach for the analysis of parasitic oscillation excitation. The electron trajectory code EGUN has been used for the estimation of the electron beam parameters in the beam tunnel. The electromagnetic simulation code CST-MS has been used for the eigenmode and Q value analysis. The analysis of the parasitic oscillations has been performed for the symmetric TE modes and the first three cavity side copper rings. Four different approaches- the Q value study, the mode maxima-electron beam radius mismatching, the electron cyclotron frequency-mode excitation frequency mismatching and the backward wave interaction analysis- have been used for the parasitic oscillation analysis.

  9. A 75 GHz silicon metal-semiconductor-metal Schottky photodiode

    International Nuclear Information System (INIS)

    Alexandrou, S.; Wang, C.; Hsiang, T.Y.; Liu, M.Y.; Chou, S.Y.

    1993-01-01

    The ultrafast characteristics of crystalline-silicon metal-semiconductor-metal (MSM) photodiodes with 300 nm finger width and spacing were measured with a subpicosecond electro-optic sampling system. Electrical responses with full width at half maximum as short as 5.5 and 11 ps, at corresponding 3 dB bandwidths of 75 and 38 GHz, were generated by violet and red photons, respectively. The difference is attributed to the photon penetration depth which is much larger than the diode finger spacing at red, but smaller at violet. Light-intensity dependence was also examined at different wavelengths, indicating a linear relation and a higher sensitivity in the violet. These results not only demonstrated the fastest silicon photodetector reported to date, but also pinpointed the dominant speed-limiting factor of silicon MSM photodiodes. A configuration is suggested to improve the speed of these detectors at long wavelengths

  10. ASTEROID SIZING BY RADIOGALAXY OCCULTATION AT 5 GHZ

    Energy Technology Data Exchange (ETDEWEB)

    Lehtinen, K.; Muinonen, K.; Poutanen, M. [Finnish Geospatial Research Institute FGI, Geodeetinrinne 2, FI-02430 Masala (Finland); Bach, U. [Max-Planck-Institut für Radioastronomie, Radioobservatorium Effelsberg, Max-Planck-Str. 28, D-53902 Bad Münstereifel-Effelsberg (Germany); Petrov, L., E-mail: kimmo.lehtinen@nls.fi [Astrogeo Center, Falls Church, VA 22043 (United States)

    2016-05-10

    Stellar occultations by asteroids observed at visual wavelengths have been an important tool for studying the size and shape of asteroids and for revising the orbital parameters of asteroids. At radio frequencies, a shadow of an asteroid on the Earth is dominated by diffraction effects. Here, we show, for the first time, that a single observation of an occultation of a compact radio source at a frequency of 5 GHz can be used to derive the effective size of the occulting object and to derive the distance between the observer and the center of the occultation path on the Earth. The derived diameter of the occulting object, asteroid (115) Thyra, is 75 ± 6 km. The observed occultation profile shows features that cannot be explained by diffraction of a single asteroid.

  11. 4-GHz counters bring synthesizers up to speed

    Science.gov (United States)

    Lee, F.; Miller, R.

    1984-06-01

    The availability of digital IC counters built on GaAs makes direct frequency division in microwave synthesizers possible. Four GHz is the highest clock rate achievable in production designs. These devices have the ability to drive TTL/CMOS logic, and the counter can be connected directly to single-chip frequency synthesizers controllers. A complete microwave sythesizer is formed by two chips and a voltage-controlled oscillator (VCO). The advantages of GaAs are discussed along with flip-flop basics, aspects of device fabrication, and the characteristics of GaAs MESAFETs. Attention is given to a GaAs prescaler usable for direct conversion, four kinds of flip-flops in a divide-by-two mode, and seven-stage binary ripple counters.

  12. COMPREHENSIVE ANALYSIS OF PREBIOTIC PROPENAL UP TO 660 GHz

    Energy Technology Data Exchange (ETDEWEB)

    Daly, A. M.; Bermúdez, C.; Kolesniková, L.; Alonso, J. L., E-mail: Adam.M.Daly@jpl.nasa.gov [Grupo de Espectroscopia Molecular (GEM), Edificio Quifima, Área de Química-Física, Laboratorios de Espectroscopia y Bioespectroscopia, Parque Científico UVa, Unidad Asociada CSIC, Universidad de Valladolid, E-47011 Valladolid (Spain)

    2015-06-22

    Since interstellar detection of propenal is only based on two rotational transitions in the centimeter wave region, its high resolution rotational spectrum has been measured up to 660 GHz and fully characterized by assignment of more than 12,000 transitions to provide direct laboratory data to the astronomical community. Spectral assignments and analysis include transitions from the ground state of the trans and cis isomers, three trans-{sup 13}C isotopologues, and ten excited vibrational states of the trans form. Combining new millimeter and submillimeter data with those from the far-infrared region has yielded the most precise set of spectroscopic constants of trans-propenal obtained to date. Newly determined rotational constants, centrifugal distortion constants, vibrational energies, and Coriolis and Fermi interaction constants are given with high accuracy and were used to predict transition frequencies and intensities over a wide frequency range. Results of this work should facilitate astronomers further observation of propenal in the interstellar medium.

  13. Intrinsic brightness temperatures of blazar jets at 15 GHz

    Directory of Open Access Journals (Sweden)

    Hovatta Talvikki

    2013-12-01

    Full Text Available We have developed a new Bayesian Markov Chain Monte Carlo method to deconvolve light curves of blazars into individual flares, including proper estimation of the fit errors. We use the method to fit 15GHzlight curves obtained within the OVRO 40-m blazar monitoring program where a large number of AGN have been monitored since 2008 in support of the Fermi Gamma-Ray Space Telescope mission. The time scales obtained from the fitted models are used to calculate the variability brightness temperature of the sources. Additionally, we have calculated brightness temperatures of a sample of these objects using Very Long Baseline Array data from the MOJAVE survey. Combining these two data sets enables us to study the intrinsic brightness temperature distribution in these blazars at 15 GHz. Our preliminary results indicate that the mean intrinsic brightness temperature in a sample of 14 sources is near the equipartition brightness temperature of ~ 1011K.

  14. Validation of an approach to predict total-tract fiber digestibility using a standardized in vitro technique for different diets fed to high-producing dairy cows.

    Science.gov (United States)

    Lopes, F; Ruh, K; Combs, D K

    2015-04-01

    The experimental objective was to validate an in vitro model to predict total-tract neutral detergent fiber (NDF) digestibility in dairy cattle. Twenty-one diets from 7 studies conducted at University of Wisconsin-Madison were analyzed for in vitro fiber digestibility. Forages varied among diets (corn, alfalfa, tall and meadow fescue, and wheat straw silages) and nutrient composition (ranges: NDF = 22.5 to 33.8%; crude protein = 15.8 to 18.9%; nonfiber carbohydrates = 38.0 to 51.0%). Total-tract NDF digestibility (TTNDFD) observed in in vivo trials was determined using different markers as described in the individual studies. The in vitro TTNDFD model predicted total-tract fiber digestibility from the proportion of total NDF potentially digestible (pdNDF), rate of pdNDF degradation, and rate of passage of pdNDF. The model predicted TTNDFD similar to in vivo measurements. The relationship between TTNDFD measured in vivo and TTNDFD predicted by the in vitro assay was significant (R(2) = 0.68). The relationship between in vitro 30-h NDF digestibility values and in vivo total-tract NDF digestibility values was not significant, whereas in vitro 48-h NDF digestibility values were correlated (R(2) = 0.30) with in vivo TTNDFD measurements. Indigestible NDF (iNDF) showed a negative relationship (R(2) = 0.40) with TTNDFD in vivo. Each 1-percentage-unit increase of iNDF resulted in a decrease of 0.96 percentage units of total-tract NDF digestibility; however, iNDF by itself was not a good predictor of TTNDFD because of the difference among the means. This study showed that an in vitro TTNDFD model that uses iNDF, pdNDF, and rates of pdNDF digestion and passage can predict (R(2) = 0.68) total-tract NDF digestibility. Most importantly, we demonstrated the ability to predict total-tract fiber digestibility from a model based on in vitro NDF degradation, which could improve our ability to optimize forage utilization and milk production. Copyright © 2015 American Dairy Science

  15. A new method to estimate left ventricular circumferential midwall systolic function by standard echocardiography: Concordance between models and validation by speckle tracking.

    Science.gov (United States)

    Ballo, Piercarlo; Nistri, Stefano; Bocelli, Arianna; Mele, Donato; Dini, Frank L; Galderisi, Maurizio; Zuppiroli, Alfredo; Mondillo, Sergio

    2016-01-15

    Assessment of left ventricular circumferential (LVcirc) systolic function by standard echocardiography can be performed by estimating midwall fractional shortening (mFS) and stress-corrected mFS (ScmFS). Their determination is based on spherical or cylindrical LV geometric models, which often yield discrepant values. We developed a new model based on a more realistic truncated ellipsoid (TE) LV shape, and explored the concordance between models among hypertensive patients. We also compared the relationships of different mFS and ScmFS estimates with indexes of LVcirc systolic strain. In 364 hypertensive subjects, mFS was determined using the spherical (mFSspher), cylindrical (mFScyl), and TE model (mFSTE). Corresponding values of ScmFSspher, ScmFScyl, and ScmFSTE were obtained. Global circumferential strain (GCS) and systolic strain rate (GCSR) were also measured by speckle tracking. The three models showed poor concordance for the estimation of mFS, with average differences ranging between 11% and 30% and wide limits of agreement. Similar results were found for ScmFS, where reclassification rates for the identification of abnormal LVcirc systolic function ranged between 18% and 29%. When tested against strain indexes, mFSTE and ScmFSTE showed the best correlations (R=0.81 and R=0.51, p<0.0001 for both) with GCS and GCSR. Multivariable analysis confirmed that mFSTE and ScmFSTE showed the strongest independent associations with LVcirc strain measures. Substantial discrepancies in LVcirc midwall systolic indexes exist between different models, supporting the need of model-specific normative data. The use of the TE model might provide indexes that show the best associations with established strain measures of LVcirc systolic function. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  16. New approaches for the standardization and validation of a real-time qPCR assay using TaqMan probes for quantification of yellow fever virus on clinical samples with high quality parameters.

    Science.gov (United States)

    Fernandes-Monteiro, Alice G; Trindade, Gisela F; Yamamura, Anna M Y; Moreira, Otacilio C; de Paula, Vanessa S; Duarte, Ana Cláudia M; Britto, Constança; Lima, Sheila Maria B

    2015-01-01

    The development and production of viral vaccines, in general, involve several steps that need the monitoring of viral load throughout the entire process. Applying a 2-step quantitative reverse transcription real time PCR assay (RT-qPCR), viral load can be measured and monitored in a few hours. In this context, the development, standardization and validation of a RT-qPCR test to quickly and efficiently quantify yellow fever virus (YFV) in all stages of vaccine production are extremely important. To serve this purpose we used a plasmid construction containing the NS5 region from 17DD YFV to generate the standard curve and to evaluate parameters such as linearity, precision and specificity against other flavivirus. Furthermore, we defined the limits of detection as 25 copies/reaction, and quantification as 100 copies/reaction for the test. To ensure the quality of the method, reference controls were established in order to avoid false negative results. The qRT-PCR technique based on the use of TaqMan probes herein standardized proved to be effective for determining yellow fever viral load both in vivo and in vitro, thus becoming a very important tool to assure the quality control for vaccine production and evaluation of viremia after vaccination or YF disease.

  17. Monte Carlo investigation of I-125 interseed attenuation for standard and thinner seeds in prostate brachytherapy with phantom validation using a MOSFET.

    Science.gov (United States)

    Mason, J; Al-Qaisieh, B; Bownes, P; Henry, A; Thwaites, D

    2013-03-01

    in prostate seed implant brachytherapy to be lower than the dose calculated by TG-43U1. MC simulation of phantom seed arrangements show that dose at a point can be reduced by up to 18% and this has been validated using a MOSFET dosimeter. Clinical simulations show that ISA reduces DVH parameter values, but the reduction is less for thinner seeds.

  18. High sensitivity broadband 360GHz passive receiver for TeraSCREEN

    Science.gov (United States)

    Wang, Hui; Oldfield, Matthew; Maestrojuán, Itziar; Platt, Duncan; Brewster, Nick; Viegas, Colin; Alderman, Byron; Ellison, Brian N.

    2016-05-01

    TeraSCREEN is an EU FP7 Security project aimed at developing a combined active, with frequency channel centered at 360 GHz, and passive, with frequency channels centered at 94, 220 and 360 GHz, imaging system for border controls in airport and commercial ferry ports. The system will include automatic threat detection and classification and has been designed with a strong focus on the ethical, legal and practical aspects of operating in these environments and with the potential threats in mind. Furthermore, both the passive and active systems are based on array receivers with the active system consisting of a 16 element MIMO FMCW radar centered at 360 GHz with a bandwidth of 30 GHz utilizing a custom made direct digital synthesizer. The 16 element passive receiver system at 360 GHz uses commercial Gunn diode oscillators at 90 GHz followed by custom made 90 to 180 GHz frequency doublers supplying the local oscillator for 360 GHz sub-harmonic mixers. This paper describes the development of the passive antenna module, local oscillator chain, frequency mixers and detectors used in the passive receiver array of this system. The complete passive receiver chain is characterized in this paper.

  19. A 65mW,0.4-2.3 GHz bandpass filter for satellite receivers

    NARCIS (Netherlands)

    Tang, van der J.D.; Kasperkovitz, D.; Bretveld, A.

    2002-01-01

    A monolithic tunable bandpass filter for satellite receiver front-ends is presented. The nter frequency of the bandpass filter can be tuned from 0.4 GHz to 2.3 GHz. The filter is constructed using four transconductor-C poly-phase filter sections and has a 50 dB variable gain range. At 20 dB

  20. 37 GHz METHANOL MASERS : HORSEMEN OF THE APOCALYPSE FOR THE CLASS II METHANOL MASER PHASE?

    International Nuclear Information System (INIS)

    Ellingsen, S. P.; Breen, S. L.; Sobolev, A. M.; Voronkov, M. A.; Caswell, J. L.; Lo, N.

    2011-01-01

    We report the results of a search for class II methanol masers at 37.7, 38.3, and 38.5 GHz toward a sample of 70 high-mass star formation regions. We primarily searched toward regions known to show emission either from the 107 GHz class II methanol maser transition, or from the 6.035 GHz excited OH transition. We detected maser emission from 13 sources in the 37.7 GHz transition, eight of these being new detections. We detected maser emission from three sources in the 38 GHz transitions, one of which is a new detection. We find that 37.7 GHz methanol masers are only associated with the most luminous 6.7 and 12.2 GHz methanol maser sources, which in turn are hypothesized to be the oldest class II methanol sources. We suggest that the 37.7 GHz methanol masers are associated with a brief evolutionary phase (of 1000-4000 years) prior to the cessation of class II methanol maser activity in the associated high-mass star formation region.

  1. HIGH RESOLUTION 36 GHz IMAGING OF THE SUPERNOVA REMNANT OF SN 1987A

    International Nuclear Information System (INIS)

    Potter, T. M.; Staveley-Smith, L.; Zanardo, G.; Ng, C.-Y.; Gaensler, B. M.; Ball, Lewis; Kesteven, M. J.; Manchester, R. N.; Tzioumis, A. K.

    2009-01-01

    The aftermath of supernova (SN) 1987A continues to provide spectacular insights into the interaction between an SN blastwave and its circumstellar environment. We here present 36 GHz observations from the Australia Telescope Compact Array of the radio remnant of SN 1987A. These new images, taken in 2008 April and 2008 October, substantially extend the frequency range of an ongoing monitoring and imaging program conducted between 1.4 and 20 GHz. Our 36.2 GHz images have a diffraction-limited angular resolution of 0.''3-0.''4, which covers the gap between high resolution, low dynamic range VLBI images of the remnant and low resolution, high dynamic range images at frequencies between 1 and 20 GHz. The radio morphology of the remnant at 36 GHz is an elliptical ring with enhanced emission on the eastern and western sides, similar to that seen previously at lower frequencies. Model fits to the data in the Fourier domain show that the emitting region is consistent with a thick inclined torus of mean radius 0.''85, and a 2008 October flux density of 27 ± 6 mJy at 36.2 GHz. The spectral index for the remnant at this epoch, determined between 1.4 GHz and 36.2 GHz, is α = -0.83. There is tentative evidence for an unresolved central source with flatter spectral index.

  2. Channel Characteristics and User Body Effects in an Outdoor Urban Scenario at 15 and 28 GHz

    DEFF Research Database (Denmark)

    Zhao, Kun; Gustafson, Carl; Liao, Qingbi

    2017-01-01

    The effect of a user’s body on channel characteristics for single user downlink transmission in an urban scenario for the 5th generation (5G) systems is investigated with ray-tracing at 15 GHz and 28 GHz. Three different designs of user equipment (UE) antennas are fabricated and integrated into a...

  3. Comparison of the noise performance of 10GHz QW and QD mode-locked laser diodes

    DEFF Research Database (Denmark)

    Carpintero, Guillermo; Thompson, Mark G.; Yvind, Kresten

    2010-01-01

    This paper reports the experimental characterization of the noise performance of a quantum dot and a quantum well 10GHz passive mode locked laser diodes.......This paper reports the experimental characterization of the noise performance of a quantum dot and a quantum well 10GHz passive mode locked laser diodes....

  4. Analysis of 38 GHz mmWave Propagation Characteristics of Urban Scenarios

    DEFF Research Database (Denmark)

    Rodriguez Larrad, Ignacio; Nguyen, Huan Cong; Sørensen, Troels Bundgaard

    2015-01-01

    The 38 GHz mm-wave frequency band is a strong candidate for the future deployment of wireless systems. Compared to lower frequency bands, propagation in the 38 GHz band is relatively unexplored for access networks in urban scenarios. This paper presents a detailed measurement-based analysis of ur...

  5. Experimental Demonstration and Theoretical Analysis of Slow Light in a Semiconductor Waveguide at GHz Frequencies

    DEFF Research Database (Denmark)

    Mørk, Jesper; Kjær, Rasmus; Poel, Mike van der

    2005-01-01

    Experimental demonstration and theoretical analysis of slow light in a semiconductor waveguide at GHz frequencies slow-down of light by a factor of two in a semiconductor waveguide at room temperature with a bandwidth of 16.7 GHz using the effect of coherent pulsations of the carrier density...

  6. A 2.4GHz ULP OOK single-chip transceiver for healthcare applications

    NARCIS (Netherlands)

    Vidojkovic, M.; Huang, X.; Harpe, P.J.A.; Rampu, S.; Zhou, C.; Huang, Li; Molengraft, van de J.; Imamura, K.; Büsze, B.; Bouwens, F.; Konijnenburg, M.; Santana, J.; Breeschoten, A.; Huisken, J.; Philips, K.; Dolmans, G.; Groot, de H.W.H.

    2011-01-01

    This paper describes an ultra-low power (ULP) single chip transceiver for wireless body area network (WBAN) applications. It supports on-off keying (OOK) modulation, and it operates in the 2.36–2.4 GHz medical BAN and 2.4–2.485 GHz ISM bands. It is implemented in 90 nm CMOS technology. The direct

  7. The EUMETSAT OSI SAF near 50 GHz sea ice emissivity model

    Directory of Open Access Journals (Sweden)

    Rasums T. Tonboe

    2013-02-01

    Full Text Available A sea ice thermal microwave emission model for 50 GHz was developed under EUMETSAT's Ocean and Sea Ice Satellite Application Facility (OSI SAF programme. The model is based on correlations between the surface brightness temperature at 18, 36 and 50 GHz. The model coefficients are estimated using simulated data from a combined thermodynamic and emission model. The intention with the model is to provide a first guess sea ice surface emissivity estimate for atmospheric temperature sounding applications in the troposphere in numerical weather prediction (NWP models assimilating Advanced Microwave Sounding Unit (AMSU and Special Sensor Microwave Imager/Sounder (SSMIS data. The spectral gradient ratio is defined as the difference over the sum of the SSMIS brightness temperatures at 18 and 36 GHz vertical linear polarisation (GR1836. The GR1836 is related to the emissivity at the atmospheric temperature sounding channels at around 50 GHz. Furthermore, the brightness temperatures and the polarisation ratio (PR at the neighbouring 18, 36 and 50 GHz channels are highly correlated. Both the gradient ratio at 18 and 36 GHz and the PR at 36 GHz measured by SSMIS are input into the model predicting the 50 GHz emissivity for horizontal and vertical linear polarisations and incidence angles between 0° and 60° The simulated emissivity is compared to the emissivity derived with alternative methods. The fit to real AMSU observations is investigated using the different emissivity estimates for simulating the observations with atmospheric data from a regional weather prediction model.

  8. Design and modeling of inductors, capacitors and coplanar waveguides at tens of GHz frequencies

    CERN Document Server

    Aryan, Naser Pour

    2015-01-01

    This book describes the basic principles of designing and modelling inductors, MIM capacitors and coplanar waveguides at frequencies of several tens of GHz. The author explains the design and modelling of key, passive elements, such as capacitors, inductors and transmission lines that enable high frequency MEMS operating at frequencies in the orders of tens of GHz.

  9. Megawatt Power Level 120 GHz Gyrotrons for ITER Start-Up

    Energy Technology Data Exchange (ETDEWEB)

    Choi, E M; Marchewka, C; Mastovsky, I; Shapiro, M A; Sirigiri, J R; Temkin, R J [MIT - Plasma Science and Fusion Center, NW16-186, 167 Albany Street, Cambridge, MA 02139 (United States)

    2005-01-01

    We report operation of a 110 GHz gyrotron with 1.67 MW of output power measured in short pulses (3{mu}s) at an efficiency of 42% in the TE{sub 22,6} mode. We also present a preliminary design of a 1 MW, 120 GHz gyrotron for ITER start-up with an efficiency greater than 50%.

  10. Megawatt Power Level 120 GHz Gyrotrons for ITER Start-Up

    International Nuclear Information System (INIS)

    Choi, E M; Marchewka, C; Mastovsky, I; Shapiro, M A; Sirigiri, J R; Temkin, R J

    2005-01-01

    We report operation of a 110 GHz gyrotron with 1.67 MW of output power measured in short pulses (3μs) at an efficiency of 42% in the TE 22,6 mode. We also present a preliminary design of a 1 MW, 120 GHz gyrotron for ITER start-up with an efficiency greater than 50%

  11. Medium access control and network layer design for 60 GHz wireless personal area networks

    NARCIS (Netherlands)

    An, X.

    2010-01-01

    The unlicensed frequency band around 60 GHz is a very promising spectrum due to its potential to provide multiple gigabits per second based data rates for short range wireless communication. Hence, 60 GHz radio is an attractive candidate to enable ultra high rate Wireless Personal Area Networks

  12. Measuring the service level in the 2.4 GHz ISM band

    NARCIS (Netherlands)

    van Bloem, J.W.H.; Schiphorst, Roelof

    2011-01-01

    In this report we provide the findings of the 2.4 GHz service level research. Here service level means the following: can all devices in the 2.4 GHz band fulfill their communication needs. In other words this corresponds to the overall Quality of Service (QoS). The project is a short research

  13. Characteristics of ocular temperature elevations after exposure to quasi- and millimeter waves (18-40 GHz)

    Science.gov (United States)

    Kojima, Masami; Suzuki, Yukihisa; Tsai, Cheng-Yu; Sasaki, Kensuke; Wake, Kanako; Watanabe, Soichi; Taki, Masao; Kamimura, Yoshitsugu; Hirata, Akimasa; Sasaki, Kazuyuki; Sasaki, Hiroshi

    2015-04-01

    In order to investigate changes in ocular temperature in rabbit eyes exposed to different frequencies (18 to 40 GHz) of quasi-millimeter waves, and millimeter waves (MMW). Pigmented rabbits were anesthetized with both general and topical anesthesia, and thermometer probes (0.5 mm in diameter) were inserted into their cornea (stroma), lens (nucleus) and vitreous (center of vitreous). The eyes were exposed unilaterally to 200 mW/cm2 by horn antenna for 3 min at 18, 22 and 26.5 GHz using a K band exposure system or 26.5, 35 and 40 GHz using a Ka band exposure system. Changes in temperature of the cornea, lens and vitreous were measured with a fluoroptic thermometer. Since the ocular temperatures after exposure to 26.5 GHz generated by the K band and Ka band systems were similar, we assumed that experimental data from these 2 exposure systems were comparable. The highest ocular temperature was induced by 40 GHz MMW, followed by 35 GHz. The 26.5 and 22 GHz corneal temperatures were almost the same. The lowest temperature was recorded at 18 GHz. The elevation in ocular temperature in response to exposure to 200 mW/cm2 MMW is dependent on MMW frequency. MMW exposure induced heat is conveyed not only to the cornea but also the crystalline lens.

  14. Market capture by 30/20 GHz satellite systems. Volume 1: Executive summary

    Science.gov (United States)

    Gamble, R. B.; Saporta, L.

    1981-01-01

    Demand for 30/20 GHz satellite systems over the next two decades is projected. Topics include a profile of the communications market, switched, dedicated, and packet transmission modes, deferred and real-time traffic, quality and reliability considerations, the capacity of competing transmission media, and scenarios for the growth and development of 30/20 GHz satellite communications.

  15. A study of parametric instability in a harmonic gyrotron: Designs of third harmonic gyrotrons at 94 GHz and 210 GHz

    International Nuclear Information System (INIS)

    Saraph, G.P.; Antonsen, T.M. Jr.; Nusinovich, G.S.; Levush, B.

    1995-01-01

    Mode competition can present a major hurdle in achieving stable, efficient operation of a gyrotron at the cyclotron harmonics. A type of mode interaction in which three modes at different cyclotron harmonics are parametrically coupled together is analyzed here. This coupling can lead to parametric excitation or suppression of a mode; cyclic mode hopping; or the coexistence of three modes. Simulation results are presented for the parametric instability involving modes at the fundamental, second harmonic, and third harmonic of the cyclotron frequency. It is shown that the parametric excitation can lead to stable, efficient operation of a high-power gyrotron at the third harmonic. Based on this phenomenon, two practical designs are presented here for the third harmonic operation at 94 and 210 GHz. copyright 1995 American Institute of Physics

  16. Feasibility Study and Experimental Verification of Simplified Fiber-Supported 60-GHz Picocell Mobile Backhaul Links

    DEFF Research Database (Denmark)

    Lebedev, Alexander; Pang, Xiaodan; Vegas Olmos, Juan José

    2013-01-01

    We propose and experimentally demonstrate a fiber-wireless transmission system for optimized delivery of 60-GHz radio frequency (RF) signals through picocell mobile backhaul connections. We identify advantages of 60-GHz links for utilization in short-range mobile backhaul through feasibility...... the wireless transmission distance from 4 m to a few hundred meters has been taken into account in the setup design, and the techniques to extend the wireless distance are analyzed....... analysis and comparison with an alternative E-band (60–90 GHz) technology. The 60-GHz fiber-wireless-fiber setup is then introduced: two spans of up to 20 km of optical fiber are deployed and bridged by up to 4 m of wireless distance. The 60-GHz radio-over-fiber technology is utilized in the first span...

  17. Unmanned Aircraft Systems Detect and Avoid System: End-to-End Verification and Validation Simulation Study of Minimum Operations Performance Standards for Integrating Unmanned Aircraft into the National Airspace System

    Science.gov (United States)

    Ghatas, Rania W.; Jack, Devin P.; Tsakpinis, Dimitrios; Sturdy, James L.; Vincent, Michael J.; Hoffler, Keith D.; Myer, Robert R.; DeHaven, Anna M.

    2017-01-01

    As Unmanned Aircraft Systems (UAS) make their way to mainstream aviation operations within the National Airspace System (NAS), research efforts are underway to develop a safe and effective environment for their integration into the NAS. Detect and Avoid (DAA) systems are required to account for the lack of "eyes in the sky" due to having no human on-board the aircraft. The technique, results, and lessons learned from a detailed End-to-End Verification and Validation (E2-V2) simulation study of a DAA system representative of RTCA SC-228's proposed Phase I DAA Minimum Operational Performance Standards (MOPS), based on specific test vectors and encounter cases, will be presented in this paper.

  18. Stochastic Channel Modeling for Railway Tunnel Scenarios at 25 GHz

    Directory of Open Access Journals (Sweden)

    Danping He

    2018-02-01

    Full Text Available More people prefer using rail traffic for travel or for commuting owing to its convenience and flexibility. The railway scenario has become an important communication scenario in the fifth generation era. The communication system should be designed to support high‐data‐rate demands with seamless connectivity at a high mobility. In this paper, the channel characteristics are studied and modeled for the railway tunnel scenario with straight and curved route shapes. On the basis of measurements using the “Mobile Hotspot Network” system, a three‐dimensional ray tracer (RT is calibrated and validated for the target scenarios. More channel characteristics are explored via RT simulations at 25.25 GHz with a 500‐MHz bandwidth. The key channel parameters are extracted, provided, and incorporated into a 3rd‐Generation‐Partnership‐Project‐like stochastic channel generator. The necessary channel information can be practically realized, which can support the link‐level and system‐level design of the communication system in similar scenarios.

  19. Validation of the G.LAB MD2200 wrist blood pressure monitor according to the European Society of Hypertension, the British Hypertension Society, and the International Organization for Standardization Protocols.

    Science.gov (United States)

    Liu, Ze-Yu; Zhang, Qing-Han; Ye, Xiao-Lei; Liu, Da-Peng; Cheng, Kang; Zhang, Chun-Hai; Wan, Yi

    2017-04-01

    To validate the G.LAB MD2200 automated wrist blood pressure (BP) monitors according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010, the British Hypertension Society (BHS), and the International Organization for Standardization (ISO) 81060-2:2013 protocols. The device was assessed on 33 participants according to the ESH requirements and was then tested on 85 participants according to the BHS and ISO 81060-2:2013 criteria. The validation procedures and data analysis followed the protocols precisely. The G.LAB MD2200 devices passed all parts of ESH-IP revision 2010 for both systolic and diastolic BP, with a device-observer difference of 2.15±5.51 and 1.51±5.16 mmHg, respectively. The device achieved A/A grading for the BHS protocol and it also fulfilled the criteria of ISO 81060-2:2013, with mean differences of systolic and diastolic BP between the device and the observer of 2.19±5.21 and 2.11±4.70 mmHg, respectively. The G.LAB MD2200 automated wrist BP monitor passed the ESH-IP revision 2010 and the ISO 81060-2:2013 protocol, and achieved the A/A grade of the BHS protocol, which can be recommended for self-measurement in the general population.

  20. 41 GHz and 10.6 GHz low threshold and low noise InAs/InP quantum dash two-section mode-locked lasers in L band

    DEFF Research Database (Denmark)

    Dontabactouny, M.; Piron, R.; Klaime, K.

    2012-01-01

    This paper reports recent results on InAs/InP quantum dash-based, two-section, passively mode-locked lasers pulsing at 41 GHz and 10.6 GHz and emitting at 1.59 mu m at 20 degrees C. The 41-GHz device (1 mm long) starts lasing at 25 mA under uniform injection and the 10.6 GHz (4 mm long) at 71 m...

  1. Analisis Kelayakan Implementasi Teknologi LTE 1.8 GHz Bagi Operator Seluler di Indonesia [Feasibility Analysis of LTE 1.8 GHz for Mobile Operators in Indonesia

    Directory of Open Access Journals (Sweden)

    Sri Ariyanti

    2015-06-01

    Full Text Available Peningkatan kebutuhan layanan data mendorong operator telekomunikasi berusaha mengimplementasikan jaringan akses broadband yang lebih handal.  Teknologi LTE merupakan salah satu teknologi dengan kecepatan mencapai tiga kali dibanding teknologi HSDPA, sehingga diharapkan dapat memenuhi kebutuhan pelanggan data mobile. Refarming frekuensi 1.8 GHz  untuk penerapan teknologi LTE memberikan efisiensi karena tidak perlu membayar BHP lagi untuk menyewa frekuensi baru. Teknologi 2G GSM selama ini juga semakin ditinggalkan, masyarakat di daerah perkotaan cenderung lebih banyak menggunakan layanan data.  Sebelum diterapkannya teknologi LTE pada frekuensi 1.8 GHz perlu adanya kajian untuk mengetahui kelayakan teknologi LTE pada frekuensi 1.8 GHz. Penelitian ini bertujuan untuk melakukan cost-benefit analysis implementasi LTE pada frekuensi 1.8 GHz.  Metode penelitian menggunakan pendekatan kualitataif yang didukung dengan data kuantitatif.  Hasil penelitian menunjukkan bahwa minimal bandiwdth yang diperlukan agar implementasi LTE layak digunakan adalah 15 MHz.  Meskipun tanpa Global Frequency Returning, penggunaan bandwidth 10 MHz tidak layak digunakan untuk implementasi LTE.      *****The incresing of data demand drives mobile operators to implement more reliable broadband access network. LTE technology has downlink peak rate up to three times than HSDPA,  hence it may fulfill the mobile data user requirement. Frequency 1.8 GHz refarming can be implemented to provide efficiency because They do not need to pay licence fee for leasing new frequency. GSM technology will be abandoned since it is not growing anymore. Besides that, dense urban users tend to use data mobile.  Before implementing LTE technology  on 1.8 GHz frequency, It is necessary to analysis the feasibility such technology. This research used qualitative method supported by quantitative  approach.  The result of this research showed that minimum bandwidth to implement 1.8 GHz LTE

  2. InP MMIC Chip Set for Power Sources Covering 80-170 GHz

    Science.gov (United States)

    Ngo, Catherine

    2001-01-01

    We will present a Monolithic Millimeter-wave Integrated Circuit (MMIC) chip set which provides high output-power sources for driving diode frequency multipliers into the terahertz range. The chip set was fabricated at HRL Laboratories using a 0.1-micrometer gate-length InAlAs/InGaAs/InP high electron mobility transistor (HEMT) process, and features transistors with an f(sub max) above 600 GHz. The HRL InP HEMT process has already demonstrated amplifiers in the 60-200 GHz range. In this paper, these high frequency HEMTs form the basis for power sources up to 170 GHz. A number of state-of-the-art InP HEMT MMICs will be presented. These include voltage-controlled and fixed-tuned oscillators, power amplifiers, and an active doubler. We will first discuss an 80 GHz voltage-controlled oscillator with 5 GHz of tunability and at least 17 mW of output power, as well as a 120 GHz oscillator providing 7 mW of output power. In addition, we will present results of a power amplifier which covers the full WRIO waveguide band (75-110 GHz), and provides 40-50 mW of output power. Furthermore, we will present an active doubler at 164 GHz providing 8% bandwidth, 3 mW of output power, and an unprecedented 2 dB of conversion loss for an InP HEMT MMIC at this frequency. Finally, we will demonstrate a power amplifier to cover 140-170 GHz with 15-25 mW of output power and 8 dB gain. These components can form a power source in the 155-165 GHz range by cascading the 80 GHz oscillator, W-band power amplifier, 164 GHz active doubler and final 140-170 GHz power amplifier for a stable, compact local oscillator subsystem, which could be used for atmospheric science or astrophysics radiometers.

  3. Explicating Validity

    Science.gov (United States)

    Kane, Michael T.

    2016-01-01

    How we choose to use a term depends on what we want to do with it. If "validity" is to be used to support a score interpretation, validation would require an analysis of the plausibility of that interpretation. If validity is to be used to support score uses, validation would require an analysis of the appropriateness of the proposed…

  4. Validation of the implementation of the basic standards of national radiological safety in radioactive facilities of the east Cuba; Valoracion de la implementacion de las normas basicas de seguridad radiologica nacionales en instalaciones radiactivas del oriente de Cuba

    Energy Technology Data Exchange (ETDEWEB)

    Perez G, F.; Fornet R, O.M. [Ministerio de Ciencia, Tecnologia y Medio Ambiente. Delegacion Territorial Holguin, Peralta No.16. Rpto Peralta, C.P. 80400 Holguin (Cuba)]. e-mail: ornuc@citmahlg.holguin.inf.cu

    2006-07-01

    Since with it publication in the Official Gazette of the Republic of Cuba began to govern the Basic Standards of Radiological Safety (NBSR) its have lapsed five years. In it practical implementation, by part of the Nuclear Regulatory Authority (ARN), several resources have been applied among those that its find the identification of the nonfulfillment of the requirements of the NBSR in the inspections, the establishment of validity conditions of the authorizations that are granted, emission and the publication of specific Safety Guides by practice. In the work it is carried out a detailed and integral analysis of the execution of those settled down requirements by the Standards in a representative group of radioactive medical and industrial facilities in the east of the country, by means of the valuation of the deficiencies and requirements pointed out in the inspections carried out during those years 2004 and 2005. As a result of the work the particularities of the level of proven implementation of this body are exposed from the point of view of the ARN that one keeps in mind for it later performance and can being of interest for others regulatory authorities. (Author)

  5. Analytical method for the identification and assay of 12 phthalates in cosmetic products: application of the ISO 12787 international standard "Cosmetics-Analytical methods-Validation criteria for analytical results using chromatographic techniques".

    Science.gov (United States)

    Gimeno, Pascal; Maggio, Annie-Françoise; Bousquet, Claudine; Quoirez, Audrey; Civade, Corinne; Bonnet, Pierre-Antoine

    2012-08-31

    Esters of phthalic acid, more commonly named phthalates, may be present in cosmetic products as ingredients or contaminants. Their presence as contaminant can be due to the manufacturing process, to raw materials used or to the migration of phthalates from packaging when plastic (polyvinyl chloride--PVC) is used. 8 phthalates (DBP, DEHP, BBP, DMEP, DnPP, DiPP, DPP, and DiBP), classified H360 or H361, are forbidden in cosmetics according to the European regulation on cosmetics 1223/2009. A GC/MS method was developed for the assay of 12 phthalates in cosmetics, including the 8 phthalates regulated. Analyses are carried out on a GC/MS system with electron impact ionization mode (EI). The separation of phthalates is obtained on a cross-linked 5%-phenyl/95%-dimethylpolysiloxane capillary column 30 m × 0.25 mm (i.d.) × 0.25 mm film thickness using a temperature gradient. Phthalate quantification is performed by external calibration using an internal standard. Validation elements obtained on standard solutions, highlight a satisfactory system conformity (resolution>1.5), a common quantification limit at 0.25 ng injected, an acceptable linearity between 0.5 μg mL⁻¹ and 5.0 μg mL⁻¹ as well as a precision and an accuracy in agreement with in-house specifications. Cosmetic samples ready for analytical injection are analyzed after a dilution in ethanol whereas more complex cosmetic matrices, like milks and creams, are assayed after a liquid/liquid extraction using ter-butyl methyl ether (TBME). Depending on the type of cosmetics analyzed, the common limits of quantification for the 12 phthalates were set at 0.5 or 2.5 μg g⁻¹. All samples were assayed using the analytical approach described in the ISO 12787 international standard "Cosmetics-Analytical methods-Validation criteria for analytical results using chromatographic techniques". This analytical protocol is particularly adapted when it is not possible to make reconstituted sample matrices. Copyright © 2012

  6. The DIII-D 3 MW, 110 GHz ECH System

    International Nuclear Information System (INIS)

    Callis, R.W.; Lohr, J.; Ponce, D.; O'Neill, R.C.; Prater, R.; Luce, T.C.

    1999-01-01

    Three 110 GHz gyrotrons with nominal output power of 1 MW each have been installed and are operational on the DIII-D tokamak. One gyrotron is built by Gycom and has a nominal rating of 1 MW and a 2 s pulse length, with the pulse length being determined by the maximum temperature allowed on the edge cooled Boron Nitride window. The second and third gyrotrons were built by Communications and Power Industries (CPI). The first CPI gyrotron uses a double disc FC-75 cooled sapphire window which has a pulse length rating of 0.8 s at 1 MW, 2s at 0.5 MW and 10s at 0.35 MW. The second CPI gyrotron, utilizes a single disc chemical-vapor-deposition diamond window, that employs water cooling around the edge of the disc. Calculation predict that the diamond window should be capable of full 1 MW cw operation. All gyrotrons are connected to the tokamak by a low-loss-windowless evacuated transmission line using circular corrugated waveguide for propagation in the HEl 1 mode. Each waveguide system incorporates a two mirror launcher which can steer the rf beam poloidally from the center to the outer edge of the plasma. Central current drive experiments with the two gyrotrons with 1.5 MW of injected power drove about 0.17 MA. Results from using the three gyrotron systems will be reported as well as the plans to upgrade the system to 6 MW

  7. ALMA Images of the Orion Hot Core at 349 GHz

    Energy Technology Data Exchange (ETDEWEB)

    Wright, M. C. H.; Plambeck, R. L., E-mail: wright@astro.berkeley.edu [Radio Astronomy Laboratory, University of California, Berkeley, CA 94720 (United States)

    2017-07-10

    We present ALMA images of the dust and molecular line emission in the Orion Hot Core at 349 GHz. At 0.″2 angular resolution the images reveal multiple clumps in an arc ∼1″ east of Orion Source I, the protostar at the center of the Kleinmann–Low Nebula, and another chain of peaks from IRc7 toward the southwest. The molecular line images show narrow filamentary structures at velocities >10 km s{sup −1} away from the heavily resolved ambient cloud velocity ∼5 km s{sup −1}. Many of these filaments trace the SiO outflow from Source I, and lie along the edges of the dust emission. Molecular line emission at excitation temperatures 300–2000 K, and velocities >10 km s{sup −1} from the ambient cloud, suggest that the Hot Core may be heated in shocks by the outflow from Source I or from the Becklin–Neugebauer (BN)/SrcI explosion. The spectral line observations also reveal a remarkable molecular ring, ∼2″ south of SrcI, with a diameter ∼600 au. The ring is seen in high-excitation transitions of HC{sub 3}N, HCN v 2 = 1, and SO{sub 2}. An impact of ejecta from the BN/SrcI explosion with a dense dust clump could result in the observed ring of shocked material.

  8. TFTR 60 GHz alpha particle collective Thomson Scattering diagnostic

    International Nuclear Information System (INIS)

    Machuzak, J.S.; Woskov, P.P.; Gilmore, J.; Bretz, N.L.; Park, H.K.; Bindslev, H.

    1995-03-01

    A 60 GHz gyrotron collective Thomson Scattering alpha particle diagnostic has been implemented for the D-T period on TFM. Gyrotron power of 0.1-1 kW in pulses of up to 1 second can be launched in X-mode. Efficient corrugated waveguides are used with antennaes and vacuum windows of the TFTR Microwave Scattering system. A multichannel synchronous detector receiver system and spectrum analyzer acquire the scattered signals. A 200 Megasample/sec digitizer is used to resolve fine structure in the frequency spectrum. By scattering nearly perpendicular to the magnetic field, this experiment will take advantage of an enhancement of the scattered signal which results from the interaction of the alpha particles with plasma resonances in the lower hybrid frequency range. Significant enhancements are expected, which will make these measurements possible with gyrotron power less than 1 kW, while maintaining an acceptable signal to noise ratio. We hope to extract alpha particle density and velocity distribution functions from the data. The D and T fuel densities and temperatures may also be obtainable by measurement of the respective ion cyclotron harmonic frequencies

  9. Diagnostics and treatment of 1.3 GHz Nb cavities

    International Nuclear Information System (INIS)

    Tamashevich, Yegor

    2017-01-01

    The European XFEL and the International Linear Collider are based on superconducting rf cavities. In order to reach the theoretical gradient limits of the superconducting cavities it is necessary to increase the mechanical quality and chemical composition of the inner surface as well as to understand the reason for performance limitations. This work is based on the diagnosis of over 100 XFEL and HiGrade cavities whose performance was limited by several factors: field emission on dust or surface defects, low-field thermal breakdown caused by the defects, Q-slope etc. It was found that some defects were produced during the mechanical production of the cavity and were not removed by electro-chemical polishing, a standard processing technique of the inner cavity surface. On the other hand, some of the defects were produced during the electro-chemical polishing process as the surface initially had imperfections or inclusions of foreign material. One of the opportunities to overcome the aforementioned drawbacks is to replace the ''bulk'' electro-chemical polishing process by mechanical centrifugal barrel polishing. The parameters of the surface after each polishing step were studied using small samples, so called coupons. An undersurface layer was investigated using metallographic techniques and cross sectioning. The influence of centrifugal polishing on the specific parameters of a 9-cell cavity (field flatness, eccentricity etc.) was investigated. As a result, a single-step centrifugal barrel polishing process followed by a standard ''light'' electropolishing was proposed for industrial application. Although the performance-limiting mechanisms are understood in general, the origin of the quench of the cavity is often unclear. To determine the quench locations, a localisation tool for thermal breakdown using the ''second sound'' in superfluid helium has been used. All components of this tool were improved to increase the accuracy of the measurements. A new program code

  10. Diagnostics and treatment of 1.3 GHz Nb cavities

    Energy Technology Data Exchange (ETDEWEB)

    Tamashevich, Yegor

    2017-01-15

    The European XFEL and the International Linear Collider are based on superconducting rf cavities. In order to reach the theoretical gradient limits of the superconducting cavities it is necessary to increase the mechanical quality and chemical composition of the inner surface as well as to understand the reason for performance limitations. This work is based on the diagnosis of over 100 XFEL and HiGrade cavities whose performance was limited by several factors: field emission on dust or surface defects, low-field thermal breakdown caused by the defects, Q-slope etc. It was found that some defects were produced during the mechanical production of the cavity and were not removed by electro-chemical polishing, a standard processing technique of the inner cavity surface. On the other hand, some of the defects were produced during the electro-chemical polishing process as the surface initially had imperfections or inclusions of foreign material. One of the opportunities to overcome the aforementioned drawbacks is to replace the ''bulk'' electro-chemical polishing process by mechanical centrifugal barrel polishing. The parameters of the surface after each polishing step were studied using small samples, so called coupons. An undersurface layer was investigated using metallographic techniques and cross sectioning. The influence of centrifugal polishing on the specific parameters of a 9-cell cavity (field flatness, eccentricity etc.) was investigated. As a result, a single-step centrifugal barrel polishing process followed by a standard ''light'' electropolishing was proposed for industrial application. Although the performance-limiting mechanisms are understood in general, the origin of the quench of the cavity is often unclear. To determine the quench locations, a localisation tool for thermal breakdown using the ''second sound'' in superfluid helium has been used. All components of this tool were improved to

  11. RADIO SOURCES FROM A 31 GHz SKY SURVEY WITH THE SUNYAEV-ZEL'DOVICH ARRAY

    International Nuclear Information System (INIS)

    Muchovej, Stephen; Hawkins, David; Lamb, James; Woody, David; Leitch, Erik; Carlstrom, John E.; Culverhouse, Thomas; Greer, Chris; Hennessy, Ryan; Loh, Michael; Marrone, Daniel P.; Pryke, Clem; Sharp, Matthew; Joy, Marshall; Miller, Amber; Mroczkowski, Tony

    2010-01-01

    We present the first sample of 31 GHz selected sources to flux levels of 1 mJy. From late 2005 to mid-2007, the Sunyaev-Zel'dovich Array observed 7.7 deg 2 of the sky at 31 GHz to a median rms of 0.18 mJy beam -1 . We identify 209 sources at greater than 5σ significance in the 31 GHz maps, ranging in flux from 0.7 mJy to ∼200 mJy. Archival NVSS data at 1.4 GHz and observations at 5 GHz with the Very Large Array are used to characterize the sources. We determine the maximum-likelihood integrated source count to be N(>S) = (27.2 ± 2.5)deg -2 x (S mJy ) -1.18±0.12 over the flux range 0.7-15 mJy. This result is significantly higher than predictions based on 1.4 GHz selected samples, a discrepancy which can be explained by a small shift in the spectral index distribution for faint 1.4 GHz sources. From comparison with previous measurements of sources within the central arcminute of massive clusters, we derive an overdensity of 6.8 ± 4.4, relative to field sources.

  12. Digital predistortion of 75–110 GHz W-band frequency multiplier for fiber wireless short range access systems

    DEFF Research Database (Denmark)

    Zhao, Ying; Deng, Lei; Pang, Xiaodan

    2011-01-01

    be effectively pre-compensated. Without using costly W-band components, a transmission system with 26km fiber and 4m wireless transmission operating at 99.6GHz is experimentally validated. Adjacent-channel power ratio (ACPR) improvements for IQ-modulated vector signals are guaranteed and transmission......We present a W-band fiber-wireless transmission system based on a nonlinear frequency multiplier for high-speed wireless short range access applications. By implementing a baseband digital signal predistortion scheme, intensive nonlinear distortions induced in a sextuple frequency multiplier can...... performances for fiber and wireless channels are studied. This W-band predistortion technique is a promising candidate for applications in high capacity wireless-fiber access systems....

  13. Three-dimensional simulation of triode-type MIG for 1 MW, 120 GHz gyrotron for ECRH applications

    Science.gov (United States)

    Singh, Udaybir; Kumar, Nitin; Kumar, Narendra; Kumar, Anil; Sinha, A. K.

    2012-01-01

    In this paper, the three-dimensional simulation of triode-type magnetron injection gun (MIG) for 120 GHz, 1 MW gyrotron is presented. The operating voltages of the modulating anode and the accelerating anode are 57 kV and 80 kV respectively. The high order TE 22,6 mode is selected as the operating mode and the electron beam is launched at the first radial maxima for the fundamental beam-mode operation. The initial design is obtained by using the in-house developed code MIGSYN. The numerical simulation is performed by using the commercially available code CST-Particle Studio (PS). The simulated results of MIG obtained by using CST-PS are validated with other simulation codes EGUN and TRAK, respectively. The results on the design output parameters obtained by using these three codes are found to be in close agreement.

  14. GML Validation Based on Norwegian Standard

    OpenAIRE

    Min, Heng

    2010-01-01

    Geographic information plays an important part in people’s life. Especially with the development of computer science and Internet. GIS also went into a new era, from paper works to digital formats. The digital geographic data files can be spread and shared fast and widely via Internet. However, establishing new geographic data is expensive, thus the data users are not always the data establisher. In the hight speed developing GI society, many private sectors have participated in geographic da...

  15. Design of a 17.14 GHz quasi-optical pulse compressor

    International Nuclear Information System (INIS)

    Petelin, M. I.; Kuzikov, S. V.; Danilov, Yu. Yu.; Granatstein, V. L.; Nusinovich, G. S.

    1999-01-01

    A quasi-optical version of the ring cavity pulse compressor is considered. This concept is based on the coupling of the input wave to a whispering gallery mode of a barrel-like cavity due to helical corrugations of the cavity wall. Low-power tests of the prototype were carried out at 11.4 GHz and demonstrated reasonable agree-ment between experimental data and theoretical predictions. The design of a similar pulse compressor at 17.14 GHz compatible with the 17.14 GHz, 100 MW gyroklystron currently under development at the University of Maryland is presented

  16. VizieR Online Data Catalog: ACT high significance 148 and 218GHz sources (Marsden+, 2014)

    Science.gov (United States)

    Marsden, D.; Gralla, M.; Marriage, T. A.; Switzer, E. R.; Partridge, B.; Massardi, M.; Morales, G.; Addison, G.; Bond, J. R.; Crichton, D.; Das, S.; Devlin, M.; Dunner, R.; Hajian, A.; Hilton, M.; Hincks, A.; Hughes, J. P.; Irwin, K.; Kosowsky, A.; Menanteau, F.; Moodley, K.; Niemack, M.; Page, L.; Reese, E. D.; Schmitt, B.; Sehgal, N.; Sievers, J.; Staggs, S.; Swetz, D.; Thornton, R.; Wollack, E.

    2014-11-01

    The ACT experiment (Swetz et al., 2011ApJS..194...41S) is situated on the slopes of Cerro Toco in the Atacama Desert of Chile at an elevation of 5190m. ACT's latitude gives access to both the northern and southern celestial hemispheres. Observations occurred simultaneously in three frequency bands, at 148GHz (2.0mm), 218GHz (1.4mm) and 277GHz (1.1mm) with angular resolutions of roughly 1.4 , 1.0 and 0.9-arcmin, respectively. (1 data file).

  17. A simple system for 160GHz optical terahertz wave generation and data modulation

    Science.gov (United States)

    Li, Yihan; He, Jingsuo; Sun, Xueming; Shi, Zexia; Wang, Ruike; Cui, Hailin; Su, Bo; Zhang, Cunlin

    2018-01-01

    A simple system based on two cascaded Mach-Zehnder modulators, which can generate 160GHz optical terahertz waves from 40GHz microwave sources, is simulated and tested in this paper. Fiber grating filter is used in the system to filter out optical carrier. By properly adjusting the modulator DC bias voltages and the signal voltages and phases, 4-tupling optical terahertz wave can be generated with fiber grating. This notch fiber grating filter is greatly suitable for terahertz over fiber (TOF) communication system. This scheme greatly reduces the cost of long-distance terahertz communication. Furthermore, 10Gbps digital signal is modulated in the 160GHz optical terahertz wave.

  18. Design of 5.8 GHz Integrated Antenna on 180nm Complementary Metal Oxide Semiconductor (CMOS) Technology

    Science.gov (United States)

    Razak, A. H. A.; Shamsuddin, M. I. A.; Idros, M. F. M.; Halim, A. K.; Ahmad, A.; Junid, S. A. M. Al

    2018-03-01

    This project discusses the design and simulation performances of integrated loop antenna. Antenna is one of the main parts in any wireless radio frequency integrated circuit (RFIC). Naturally, antenna is the bulk in any RFIC design. Thus, this project aims to implement an integrated antenna on a single chip making the end product more compact. This project targets 5.8 GHz as the operating frequency of the integrated antenna for a transceiver module based on Silterra CMOS 180nm technology. The simulation of the antenna was done by using High Frequency Structure Simulator (HFSS). This software is industrial standard software that been used to simulate all electromagnetic effect including antenna simulation. This software has ability to simulate frequency at range of 100 MHz to 4 THz. The simulation set up in 3 dimension structure with driven terminal. The designed antenna has 1400um of diameter and placed on top metal layer. Loop configuration of the antenna has been chosen as the antenna design. From the configuration, it is able to make the chip more compact. The simulation shows that the antenna has single frequency band at center frequency 5.8 GHz with -48.93dB. The antenna radiation patterns shows, the antenna radiate at omnidirectional. From the simulation result, it could be concluded that the antenna have a good radiation pattern and propagation for wireless communication.

  19. Quasi-optical internal mode converters for 110 GHz gyrotrons

    International Nuclear Information System (INIS)

    Harper, B.M.; Lorbeck, J.A.; Vernon, R.J.

    1995-01-01

    Many early gyrotrons had a microwave output in the same mode that was produced in the microwave cavity, e.g. the TE 02 mode. These modes were often converted outside of the tube to a more desirable mode for plasma heating using a system of perturbed-wall waveguide mode converters. The current generation of gyrotrons commonly have cavity modes with a high azimuthal index, such as the rotating TE 22,6 mode. Mode conversion by means of waveguide mode converters is not usually practical for such cases. However, an output of a Gaussian beam or other desirable field pattern can be obtained by using a Vlasov-type launcher feeding a series of two or more reflectors. This system may be placed outside or inside of the gyrotron but there are advantages to placing it within the tube, e.g. allowing for a larger collector and smaller reflectors. When such a converter system is placed inside the gyrotron, it is usually preferable to use a modification to the simple Vlasov launcher such as the Denisov-type launcher, which incorporates a series of perturbations within it. The authors have designed both internal and external versions of such quasi-optical converters. They discuss an internal converter which was designed for use inside of a Varian 110 GHz gyrotron producing the TE 22,6 cavity mode. This design consists of four reflectors which are fed by a Denisov-type launcher. Design techniques for the reflector system are discussed and experimental results are presented

  20. Optimization, validation and standardization of a method of measuring the radiochemical purity of {sup 99m}Tc-HMDP in Necker hospital; Optimisation, validation et standardisation d`une methode de mesure de la purete radiochimique du {sup 99m}Tc-HMDP a l`hopital Necker

    Energy Technology Data Exchange (ETDEWEB)

    Dumont, A.; Izembart, M.; Barritault, L. [Hopital Necker, Paris (France)

    1997-12-31

    By the end of 1996, the tests of the radiochemical purity (RCP) of preparation of HMDP-{sup 99m}Tc at Necker hospital were effected by means of `Tech-Kit` technique which allowed making evident only one radiochemical impurity, the free TcO{sub 4}{sup -}. So, the aim of this work has been the search for another technique able to detect also the reduced hydrolyzed {sup 99m}Tc, and then, to optimize, validate and standardize this new technique. Several methods have been tested and compared on different points (the chemical species identified, practical difficulties, duration, reproducibility) in order to chose `the best` one, consisting in associating two TLC (migration time, 3 minutes): - TLC no.1, ITLC-SG/Methyl-ethyl-ketone; - TLC no.2, ITLC-SG/1M Sodium acetate. This method has been subsequently: - optimized, concerning the quantity of deposed sampling, way of deposit drying, migration range, reading protocol by radio-chromatograph; - validated, by verifying the migration of radiochemical impurities by means of controls and by evaluating its sensitivity; - standardized, by defining the interest zones for interpreting the radio-chromatograms, by evaluating the reproducibility and by calculating the `normal values` of RCP percentages. This method has been adopted as routine and with current recoil (40 preparations) and our conditions of realizations, the extreme values of the percentages obtained for the impurity zones of interests, have been the following: - TcO{sub 4}{sup -} zone, [0.39%-1.07%]; - hydrolyzed reduced Tc zone, [0.96%-5.09%]. By taking into account their distribution we calculated a minimum RCP value of 94% to accept the preparation (the RCP being defined as equal to 100% - % TcO{sub 4}{sup -} % hydrolyzed reduced Tc)

  1. Miniature Packaging Concept for LNAs in the 200-300 GHz Range

    Science.gov (United States)

    Samoska, Lorene; Fung, Andy; Varonen, Mikko; Lin, Robert; Peralta, Alejandro; Soria, Mary; Lee, Choonsup; Padmanabhan, Sharmila; Sarkozy, Stephen; Lai, Richard

    2016-01-01

    In this work, we describe new miniaturized low noise amplifier modules which we developed for incorporation in small-scale satellites or Cubesats, and which exhibit similar or better performance compared to previously reported LNAs in the literature. We have targeted the WR4 (170-260 GHz) and WR3 (220-325 GHz) waveguide bands for the module development. The modules include two different methods of E-plane probes which have been developed for low loss, and stability at high frequencies. MMIC LNAs were also developed for these frequency ranges and fabricated in Northrop Grumman Corporation's 35 nm InP HEMT technology, and we have experimentally verified that noise performance is lower than reported in prior work. The best results include a miniature LNA module with 550K noise at 224 GHz, and a wideband LNA module with 15 dB gain from 230-280 GHz.

  2. Short optical pulse generation at 40 GHz with a bulk electro-absorption modulator packaged device

    Science.gov (United States)

    Langlois, Patrick; Moore, Ronald; Prosyk, Kelvin; O'Keefe, Sean; Oosterom, Jill A.; Betty, Ian; Foster, Robert; Greenspan, Jonathan; Singh, Priti

    2003-12-01

    Short optical pulse generation at 40GHz and 1540nm wavelength is achieved using fully packaged bulk quaternary electro-absorption modulator modules. Experimental results obtained with broadband and narrowband optimized packaged modules are presented and compared against empirical model predictions. Pulse duty cycle, extinction ratio and chirp are studied as a function of sinusoidal drive voltage and detuning between operating wavelength and modulator absorption band edge. Design rules and performance trade-offs are discussed. Low-chirp pulses with a FWHM of ~12ps and sub-4ps at a rate of 40GHz are demonstrated. Optical time-domain demultiplexing of a 40GHz to a 10GHz pulse train is also demonstrated with better than 20dB extinction ratio.

  3. Development of 24GHz Rectenna for Receiving and Rectifying Modulated Waves

    International Nuclear Information System (INIS)

    Shinohara, Naoki; Hatano, Ken

    2014-01-01

    In this paper, we show experimental results of RF-DC conversion with modulated 24GHz waves. We have already developed class-F MMIC rectenna with resonators for higher harmonics at no modulated 24GHz microwave for RF energy transfer. Dimensions of the MMIC rectifying circuit is 1 mm × 3 mm on GaAs. Maximum RF-DC conversion efficiency is measured 47.9% for a 210 mW microwave input of 24 GHz with a 120 Ω load. The class-F rectenna is based on a single shunt full-wave rectifier. For future application of a simultaneous energy and information transfer system or an energy harvesting from broadcasting waves, input microwave will be modulated. In this paper, we show an experimental result of RF-DC conversion of the class-F rectenna with 24GHz waves modulated by 16QAM as 1st modulation and OFDM as 2nd modulation

  4. Development of 24GHz Rectenna for Receiving and Rectifying Modulated Waves

    Science.gov (United States)

    Shinohara, Naoki; Hatano, Ken

    2014-11-01

    In this paper, we show experimental results of RF-DC conversion with modulated 24GHz waves. We have already developed class-F MMIC rectenna with resonators for higher harmonics at no modulated 24GHz microwave for RF energy transfer. Dimensions of the MMIC rectifying circuit is 1 mm × 3 mm on GaAs. Maximum RF-DC conversion efficiency is measured 47.9% for a 210 mW microwave input of 24 GHz with a 120 Ω load. The class-F rectenna is based on a single shunt full-wave rectifier. For future application of a simultaneous energy and information transfer system or an energy harvesting from broadcasting waves, input microwave will be modulated. In this paper, we show an experimental result of RF-DC conversion of the class-F rectenna with 24GHz waves modulated by 16QAM as 1st modulation and OFDM as 2nd modulation.

  5. Results of RIKEN superconducting electron cyclotron resonance ion source with 28 GHz.

    Science.gov (United States)

    Higurashi, Y; Ohnishi, J; Nakagawa, T; Haba, H; Tamura, M; Aihara, T; Fujimaki, M; Komiyama, M; Uchiyama, A; Kamigaito, O

    2012-02-01

    We measured the beam intensity of highly charged heavy ions and x-ray heat load for RIKEN superconducting electron cyclotron resonance ion source with 28 GHz microwaves under the various conditions. The beam intensity of Xe(20+) became maximum at B(min) ∼ 0.65 T, which was ∼65% of the magnetic field strength of electron cyclotron resonance (B(ECR)) for 28 GHz microwaves. We observed that the heat load of x-ray increased with decreasing gas pressure and field gradient at resonance zone. It seems that the beam intensity of highly charged heavy ions with 28 GHz is higher than that with 18 GHz at same RF power.

  6. 80 Gbit/s 16-QAM Multicarrier THz Wireless Communication Link in the 400 GHz Band

    DEFF Research Database (Denmark)

    Jia, Shi; Yu, Xianbin; Hu, Hao

    2016-01-01

    We experimentally demonstrate a high-speed multicarrier THz wireless communication system operating in the 400 GHz band. The use of spectrally efficient 16-QAM modulation and broadband THz transceivers enable link data rates up to 80 Gbit/s....

  7. Short-duration exposure to 2.45 GHz microwave radiation induces ...

    African Journals Online (AJOL)

    OBEMBE

    The genotoxic effects of 2.45 GHz microwave (MW) radiation on the testis ... electromagnetic radiation present in the environment and ..... intrinsic (quantum) energy is too low to dislodge an .... wave on brain enzymes of developing rat brain.

  8. Microfabricated, 94 GHz, 25 W, Helical Traveling Wave Tube, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Teraphysics Corporation completed the Phase I objectives for the electrical design of a 94 GHz, 26 W TWT with 53% overall efficiency, including the helical circuit...

  9. 160 Gbit/s photonics wireless transmission in the 300-500 GHz band

    Directory of Open Access Journals (Sweden)

    X. Yu

    2016-11-01

    Full Text Available To accommodate the ever increasing wireless traffic in the access networks, considerable efforts have been recently invested in developing photonics-assisted wireless communication systems with very high data rates. Superior to photonic millimeter-wave systems, terahertz (THz band (300 GHz-10 THz provides a much larger bandwidth and thus promises an extremely high capacity. However, the capacity potential of THz wireless systems has by no means been achieved yet. Here, we successfully demonstrate 160 Gbit/s wireless transmission by using a single THz emitter and modulating 25 GHz spaced 8 channels (20 Gbps per channel in the 300-500 GHz band, which is the highest bitrate in the frequency band above 300 GHz, to the best of our knowledge.

  10. Generation of large scale GHZ states with the interactions of photons and quantum-dot spins

    Science.gov (United States)

    Miao, Chun; Fang, Shu-Dong; Dong, Ping; Yang, Ming; Cao, Zhuo-Liang

    2018-03-01

    We present a deterministic scheme for generating large scale GHZ states in a cavity-quantum dot system. A singly charged quantum dot is embedded in a double-sided optical microcavity with partially reflective top and bottom mirrors. The GHZ-type Bell spin state can be created and two n-spin GHZ states can be perfectly fused to a 2n-spin GHZ state with the help of n ancilla single-photon pulses. The implementation of the current scheme only depends on the photon detection and its need not to operate multi-qubit gates and multi-qubit measurements. Discussions about the effect of the cavity loss, side leakage and exciton cavity coupling strength for the fidelity of generated states show that the fidelity can remain high enough by controlling system parameters. So the current scheme is simple and feasible in experiment.

  11. VizieR Online Data Catalog: 22GHz image of 3C 273 (Bruni+, 2017)

    Science.gov (United States)

    Bruni, G.; Gomez, J. L.; Casadio, C.; Lobanov, A.; Kovalev, Y. Y.; Sokolovsky, K. V.; Lisakov, M. M.; Bach, U.; Marscher, A.; Jorstad, S.; Anderson, J. M.; Krichbaum, T. P.; Savolainen, T.; Vega-Garcia, L.; Fuentes, A.; Zensus, J. A.; Alberdi, A.; Lee, S.-S.; Lu, R.-S.; Perez-Torres, M.; Ros, E.

    2017-07-01

    A global ground array of 22 antennas was used to perform observations, including VLBA (Sc, Hn, Nl, Fd, La, Kp, Pt, Ov, Br, Mk), EVN (Hh, Mc, Nt, Tr, Jb, Ef, Ys), Long Baseline Array (-LBA- At, Mp, Ho, Cd), and two Kvazar antennas (Sv, Zc), plus Kalyazin (managed by ASC, Russia), and Green Bank (NRAO, USA). The observations took place on January 18-19, 2014, for a total of 16.8 hours, and at three different frequencies: 15GHz, 22GHz, and 43GHz. RA was involved only for the 22GHz part, while for the other bands only the VLBA was used. Both the Green Bank and Pushchino tracking station took part in the experiment. A RA-compatible total bandwidth of 32MHz, split into two 16-MHz IFs, was used. RA was scheduled to observe three consecutive 9.5 minute scans every 1.25 hours, to allow for antenna cooling. (2 data files).

  12. A 31 GHz Survey of Low-Frequency Selected Radio Sources

    Science.gov (United States)

    Mason, B. S.; Weintraub, L.; Sievers, J.; Bond, J. R.; Myers, S. T.; Pearson, T. J.; Readhead, A. C. S.; Shepherd, M. C.

    2009-10-01

    The 100 m Robert C. Byrd Green Bank Telescope and the 40 m Owens Valley Radio Observatory telescope have been used to conduct a 31 GHz survey of 3165 known extragalactic radio sources over 143 deg2 of the sky. Target sources were selected from the NRAO VLA Sky Survey in fields observed by the Cosmic Background Imager (CBI); most are extragalactic active galactic nuclei (AGNs) with 1.4 GHz flux densities of 3-10 mJy. The resulting 31 GHz catalogs are presented in full online. Using a maximum-likelihood analysis to obtain an unbiased estimate of the distribution of the 1.4-31 GHz spectral indices of these sources, we find a mean 31-1.4 GHz flux ratio of 0.110 ± 0.003 corresponding to a spectral index of α = -0.71 ± 0.01 (S ν vprop να) 9.0% ± 0.8% of sources have α > - 0.5 and 1.2% ± 0.2% have α > 0. By combining this spectral-index distribution with 1.4 GHz source counts, we predict 31 GHz source counts in the range 1 mJy S 31) = (16.7 ± 1.7) deg-2(S 31/1 mJy)-0.80±0.07. We also assess the contribution of mJy-level (S 1.4 GHz < 3.4 mJy) radio sources to the 31 GHz cosmic microwave background power spectrum, finding a mean power of ell(ell + 1)C src ell/(2π) = 44 ± 14 μK2 and a 95% upper limit of 80 μK2 at ell = 2500. Including an estimated contribution of 12 μK2 from the population of sources responsible for the turn-up in counts below S 1.4 GHz = 1 mJy, this amounts to 21% ± 7% of what is needed to explain the CBI high-ell excess signal, 275 ± 63 μK2. These results are consistent with other measurements of the 31 GHz point-source foreground.

  13. Photonic filtering of microwave signals in the frequency range of 0.01-20 GHz using a Fabry-Perot filter

    Energy Technology Data Exchange (ETDEWEB)

    Aguayo-Rodriguez, G; Zaldivar-Huerta, I E [Instituto Nacional de Astrofisica, Optica y Electronica (INAOE). Sta. Maria Tonantzintla, Pue. Mexico (Mexico); GarcIa-Juarez, A [Depto. de Investigacion en Fisica, Universidad de Sonora (UNISON) Hermosillo, Son. Mexico (Mexico); Rodriguez-Asomoza, J [Depto. de Ingenieria Electronica, Universidad de las Americas-Puebla (UDLA). San Andres Cholula, Pue. Mexico (Mexico); Larger, L; Courjal, N [Laboratoire d' Optique P. M. Duffieux, UMR 6603 CNRS, Institut des Microtechiques de Franche-Comte, FRW 0067, UFR Sciences et Techniques, Universite de Franche-Comte (UFC), Besancon cedex (France)

    2011-01-01

    We demonstrate experimentally the efficiency of tuning of a photonic filter in the frequency range of 0.01 to 20 GHz. The presented work combines the use of a multimode optical source associated with a dispersive optical fiber to obtain the filtering effect. Tunability effect is achieved by the use of a Fabry-Perot filter that allows altering the spectral characteristics of the optical source. Experimental results are validated by means of numerical simulations. The scheme here proposed has a potential application in the field of optical telecommunications.

  14. The Experimental Verification of Gaussian Beam Coupling for ECH Transmission Line at 400 GHz

    Directory of Open Access Journals (Sweden)

    Choe Mun Seok

    2017-01-01

    Full Text Available We design a quasi-optical transmission line system for a 400 GHz gyrotron beam. The 400GHz Gaussian beam is injected to a corrugated waveguide bounced from a quasi-optical mirror. From detailed 2D field patterns of the output beam emitted from the corrugated waveguide, we analyze the mode contents and the source of non-ideal beam expansion

  15. The Cosmology Large Angular Scale Surveyor (CLASS): 38 GHz Detector Array of Bolometric Polarimeters

    Science.gov (United States)

    Appel, John W.; Ali, Aamir; Amiri, Mandana; Araujo, Derek; Bennett, Charles L.; Boone, Fletcher; Chan, Manwei; Cho, Hsiao-Mei; Chuss, David T.; Colazo, Felipe; hide

    2014-01-01

    The Cosmology Large Angular Scale Surveyor (CLASS) experiment aims to map the polarization of the Cosmic Microwave Background (CMB) at angular scales larger than a few degrees. Operating from Cerro Toco in the Atacama Desert of Chile, it will observe over 65% of the sky at 38, 93, 148, and 217 GHz. In this paper we discuss the design, construction, and characterization of the CLASS 38 GHz detector focal plane, the first ever Q-band bolometric polarimeter array.

  16. The cosmology large angular scale surveyor (CLASS): 38-GHz detector array of bolometric polarimeters

    Science.gov (United States)

    Appel, John W.; Ali, Aamir; Amiri, Mandana; Araujo, Derek; Bennet, Charles L.; Boone, Fletcher; Chan, Manwei; Cho, Hsiao-Mei; Chuss, David T.; Colazo, Felipe; Crowe, Erik; Denis, Kevin; Dünner, Rolando; Eimer, Joseph; Essinger-Hileman, Thomas; Gothe, Dominik; Halpern, Mark; Harrington, Kathleen; Hilton, Gene; Hinshaw, Gary F.; Huang, Caroline; Irwin, Kent; Jones, Glenn; Karakula, John; Kogut, Alan J.; Larson, David; Limon, Michele; Lowry, Lindsay; Marriage, Tobias; Mehrle, Nicholas; Miller, Amber D.; Miller, Nathan; Moseley, Samuel H.; Novak, Giles; Reintsema, Carl; Rostem, Karwan; Stevenson, Thomas; Towner, Deborah; U-Yen, Kongpop; Wagner, Emily; Watts, Duncan; Wollack, Edward; Xu, Zhilei; Zeng, Lingzhen

    2014-07-01

    The Cosmology Large Angular Scale Surveyor (CLASS) experiment aims to map the polarization of the Cosmic Microwave Background (CMB) at angular scales larger than a few degrees. Operating from Cerro Toco in the Atacama Desert of Chile, it will observe over 65% of the sky at 38, 93, 148, and 217 GHz. In this paper we discuss the design, construction, and characterization of the CLASS 38 GHz detector focal plane, the first ever Q-band bolometric polarimeter array.

  17. Toward 100 GHz direct modulation rate of antenna coupled nanoLED

    DEFF Research Database (Denmark)

    Fortuna, Seth A.; Taghizadeh, Alireza; Yablonovitch, Eli

    2016-01-01

    We show that > 100 GHz direct modulation rate while maintaining a quantum efficiency higher than 25% is possible by using an optical antenna to enhance the spontaneous emission rate of an electrically injected III-V nanoLED.......We show that > 100 GHz direct modulation rate while maintaining a quantum efficiency higher than 25% is possible by using an optical antenna to enhance the spontaneous emission rate of an electrically injected III-V nanoLED....

  18. FIRST INTERFEROMETRIC IMAGES OF THE 36 GHz METHANOL MASERS IN THE DR21 COMPLEX

    International Nuclear Information System (INIS)

    Fish, Vincent L.; Muehlbrad, Talitha C.; Pratap, Preethi; Sjouwerman, Lorant O.; Strelnitski, Vladimir; Pihlstroem, Ylva M.; Bourke, Tyler L.

    2011-01-01

    Class I methanol masers are believed to be produced in the shock-excited environment around star-forming regions. Many authors have argued that the appearance of various subsets of class I masers may be indicative of specific evolutionary stages of star formation or excitation conditions. Until recently, however, no major interferometer was capable of imaging the important 36 GHz transition. We report on Expanded Very Large Array observations of the 36 GHz methanol masers and Submillimeter Array observations of the 229 GHz methanol masers in DR21(OH), DR21N, and DR21W. The distribution of 36 GHz masers in the outflow of DR21(OH) is similar to that of the other class I methanol transitions, with numerous multitransition spatial overlaps. At the site of the main continuum source in DR21(OH), class I masers at 36 and 229 GHz are found in virtual overlap with class II 6.7 GHz masers. To the south of the outflow, the 36 GHz masers are scattered over a large region but usually do not appear coincident with 44 GHz masers. In DR21W, we detect an 'S-curve' signature in Stokes V that implies a large value of the magnetic field strength if interpreted as due to Zeeman splitting, suggesting either that class I masers may exist at higher densities than previously believed or that the direct Zeeman interpretation of S-curve Stokes V profiles in class I masers may be incorrect. We find a diverse variety of different maser phenomena in these sources, suggestive of differing physical conditions among them.

  19. Steganalysis and improvement of a quantum steganography protocol via a GHZ4 state

    International Nuclear Information System (INIS)

    Xu Shu-Jiang; Chen Xiu-Bo; Niu Xin-Xin; Yang Yi-Xian

    2013-01-01

    Quantum steganography that utilizes the quantum mechanical effect to achieve the purpose of information hiding is a popular topic of quantum information. Recently, El Allati et al. proposed a new quantum steganography using the GHZ 4 state. Since all of the 8 groups of unitary transformations used in the secret message encoding rule change the GHZ 4 state into 6 instead of 8 different quantum states when the global phase is not considered, we point out that a 2-bit instead of a 3-bit secret message can be encoded by one group of the given unitary transformations. To encode a 3-bit secret message by performing a group of unitary transformations on the GHZ 4 state, we give another 8 groups of unitary transformations that can change the GHZ 4 state into 8 different quantum states. Due to the symmetry of the GHZ 4 state, all the possible 16 groups of unitary transformations change the GHZ 4 state into 8 different quantum states, so the improved protocol achieves a high efficiency

  20. A low noise 665 GHz SIS quasi-particle waveguide receiver

    Science.gov (United States)

    Kooi, J. W.; Walker, C. K.; Leduc, H. G.; Hunter, T. R.; Benford, D. J.; Phillips, T. G.

    1993-01-01

    Recent results on a 565-690 GHz SIS heterodyne receiver employing a 0.36 micron(sup 2) Nb/AlOx/Nb SIS tunnel junction with high quality circular non-contacting back short and E-plane tuners in a full height wave guide mount are reported. No resonant tuning structures were incorporated in the junction design at this time, even though such structures are expected to help the performance of the receiver. The receiver operates to at least the gap frequency of Niobium, approximately 680 GHz. Typical receiver noise temperatures from 565-690 GHz range from 160K to 230K with a best value of 185K DSB at 648 GHz. With the mixer cooled from 4.3K to 2K the measured receiver noise temperatures decreased by approximately 15 percent, giving roughly 180K DSB from 660 to 680 GHz. The receiver has a full 1 GHz IF pass band and was successfully installed at the Caltech Submillimeter Observatory in Hawaii.