WorldWideScience

Sample records for gfrp reinforcing bars

  1. Behavior of reinforced concrete beams reinforced with GFRP bars

    Directory of Open Access Journals (Sweden)

    D. H. Tavares

    Full Text Available The use of fiber reinforced polymer (FRP bars is one of the alternatives presented in recent studies to prevent the drawbacks related to the steel reinforcement in specific reinforced concrete members. In this work, six reinforced concrete beams were submitted to four point bending tests. One beam was reinforced with CA-50 steel bars and five with glass fiber reinforced polymer (GFRP bars. The tests were carried out in the Department of Structural Engineering in São Carlos Engineering School, São Paulo University. The objective of the test program was to compare strength, reinforcement deformation, displacement, and some anchorage aspects between the GFRP-reinforced concrete beams and the steel-reinforced concrete beam. The results show that, even though four GFRP-reinforced concrete beams were designed with the same internal tension force as that with steel reinforcement, their capacity was lower than that of the steel-reinforced beam. The results also show that similar flexural capacity can be achieved for the steel- and for the GFRP-reinforced concrete beams by controlling the stiffness (reinforcement modulus of elasticity multiplied by the bar cross-sectional area - EA and the tension force of the GFRP bars.

  2. Health monitoring of precast bridge deck panels reinforced with glass fiber reinforced polymer (GFRP) bars.

    Science.gov (United States)

    2012-03-01

    The present research project investigates monitoring concrete precast panels for bridge decks that are reinforced with Glass Fiber Reinforced Polymer (GFRP) bars. Due to the lack of long term research on concrete members reinforced with GFRP bars, lo...

  3. Preparation and characterization of glass fibers – polymers (epoxy bars (GFRP reinforced concrete for structural applications

    Directory of Open Access Journals (Sweden)

    Alkjk Saeed

    2016-06-01

    Full Text Available The paper presents some of the results from a large experimental program undertaken at the Department of Civil Engineering of Damascus University. The project aims to study the ability to reinforce and strengthen the concrete by bars from Epoxy polymer reinforced with glass fibers (GFRP and compared with reinforce concrete by steel bars in terms of mechanical properties. Five diameters of GFRP bars, and steel bars (4mm, 6mm, 8mm, 10mm, 12mm tested on tensile strength tests. The test shown that GFRP bars need tensile strength more than steel bars. The concrete beams measuring (15cm wide × 15cm deep × and 70cm long reinforced by GFRP with 0.5 vol.% ratio, then the concrete beams reinforced by steel with 0.89 vol.% ratio. The concrete beams tested on deflection test. The test shown that beams which reinforced by GFRP has higher deflection resistance, than beams which reinforced by steel. Which give more advantage to reinforced concrete by GFRP.

  4. Flexural strengthening of reinforced lightweight polystyrene aggregate concrete beams with near-surface mounted GFRP bars

    Energy Technology Data Exchange (ETDEWEB)

    Tang, W.C.; Balendran, R.V.; Nadeem, A.; Leung, H.Y. [City University of Hong Kong (China). Department of Building and Construction

    2006-10-15

    Application of near-surface mounted (NSM) fibre reinforced polymer (FRP) bars is emerging as a promising technology for increasing flexural and shear strength of deficient reinforced concrete (RC) members. In order for this technique to perform effectively, the structural behaviour of RC elements strengthened with NSM FRP bars needs to be fully characterized. This paper focuses on the characterization of flexural behaviour of RC members strengthened with NSM glass-FRP bars. Totally, 10 beams were tested using symmetrical two-point loads test. The parameters examined under the beam tests were type of concretes (lightweight polystyrene aggregate concrete and normal concrete), type of reinforcing bars (GFRP and steel), and type of adhesives. Flexural performance of the tested beams including modes of failure, moment-deflection response and ultimate moment capacity are presented and discussed in this paper. Results of this investigation showed that beams with NSM GFRP bars showed a reduction in ultimate deflection and an improvement in flexural stiffness and bending capacity, depending on the PA content of the beams. In general, beams strengthened with NSM GFRP bars overall showed a significant increase in ultimate moment ranging from 23% to 53% over the corresponding beams without NSM GFRP bars. The influence of epoxy type was found conspicuously dominated the moment-deflection response up to the peak moment. Besides, the ultimate moment of concrete beams reinforced with GFRP bars could be predicted satisfactorily using the equation provided in ACI 318-95 Building Code. (author)

  5. Numerical Study on Deflection Behaviour of Concrete Beams Reinforced with GFRP Bars

    Science.gov (United States)

    Mohamed, Osama A.; Khattab, Rania; Hawat, Waddah Al

    2017-10-01

    Fiber-Reinforced Polymer (FRP) bars are gaining popularity as sustainable alternatives to conventional reinforcing steel bars in reinforced concrete applications. The production of FRP bars has lower environmental impact compared to steel reinforcing bars. In addition, the non-corroding FRP materials can potentially decrease the cost or need for maintenance of reinforced concrete structural elements, especially in harsh environmental conditions that can impact both concrete and reinforcement. FRP bars offer additional favourable properties including high tensile strength and low unit weight. However, the mechanical properties of FRP bars can lead to large crack widths and deflections. The objective of this study is to investigate the deflection behaviour of concrete beams reinforced with Glass FRP (GFRP) bars as a longitudinal main reinforcement. Six concrete beams reinforced with GFRP bars were modelled using the finite element computer program ANSYS. The main variable considered in the study is the reinforcement ratio. The deflection equations in current North American codes including ACI 440.1R-06, ACI 440.1R-15 and CSA S806-12 are used to compute deflections, and these are compared to numerical results. It was concluded in this paper that deflections predicted by ACI 440.1R-06 equations are lower than the numerical analysis results while ACI 440.1R-15 is in agreement with numerical analysis with tendency to be conservative. The values of deflections estimated by CSA S806-12 formulas are consistent with results of numerical analysis.

  6. Comparison of Failure Process of Bended Beams Reinforced with Steel Bars and GFRP Bars

    Science.gov (United States)

    Kaszyńska, Maria; Błyszko, Jarosław; Olczyk, Norbert

    2017-10-01

    load were tested. Both types of beams were designed to have the same bearing capacity. Beams reinforced with GFRP rebar exhibited much bigger cracking than traditionally reinforced bars. The width of cracks appearing in beams reinforced with GFRP bars was equal or greater than limit values (0.4 mm) even though the ratio of moment of resistance and cracking moment was greater than 3. The composite rebar exhibits many significant advantages over steel rebar, but its rather low Young’s modulus comparing to steel causes exceeded deflection and cracking of bended concrete elements.

  7. Experimental Assessment on the Flexural Bonding Performance of Concrete Beam with GFRP Reinforcing Bar under Repeated Loading

    Directory of Open Access Journals (Sweden)

    Minkwan Ju

    2015-01-01

    Full Text Available This study intends to investigate the flexural bond performance of glass fiber-reinforced polymer (GFRP reinforcing bar under repeated loading. The flexural bond tests reinforced with GFRP reinforcing bars were carried out according to the BS EN 12269-1 (2000 specification. The bond test consisted of three loading schemes: static, monotonic, and variable-amplitude loading to simulate ambient loading conditions. The empirical bond length based on the static test was 225 mm, whereas it was 317 mm according to ACI 440 1R-03. Each bond stress on the rib is released and bonding force is enhanced as the bond length is increased. Appropriate level of bond length may be recommended with this energy-based analysis. For the monotonic loading test, the bond strengths at pullout failure after 2,000,000 cycles were 10.4 MPa and 6.5 MPa, respectively: 63–70% of the values from the static loading test. The variable loading test indicated that the linear cumulative damage theory on GFRP bonding may not be appropriate for estimating the fatigue limit when subjected to variable-amplitude loading.

  8. Durability and service life prediction of GFRP bars embedded in concrete under acid environment

    Energy Technology Data Exchange (ETDEWEB)

    Zhou Jikai, E-mail: jkzhou@hotmail.com [College of Civil and Transportation Engineering, Hohai University, Nanjing, Jiangsu 210098 (China); Chen Xudong, E-mail: cxdong1985@hotmail.com [College of Civil and Transportation Engineering, Hohai University, Nanjing, Jiangsu 210098 (China); Chen Shixue, E-mail: 710567525@qq.com [College of Civil and Transportation Engineering, Hohai University, Nanjing, Jiangsu 210098 (China)

    2011-10-15

    Highlights: > Bond strength of GFRP bars decrease with an increase in pH of acid solutions. > Bond strength of steel bars decrease with an increase in pH of acid solutions. > Durability of GFRP bars could be predicted by modified Arrhenius relation. - Abstract: In recent years, glass fiber reinforcing polymers (GFRP) has emerged as an alternative to conventional steel reinforcing bars in concrete structures. The bond behavior of GFRP bars to concrete under acidic environment is important because of increasing acid rain in China nowadays. This paper presents an experimental investigation into comparison of the durability of the bond between GFRP and steel bars to concrete under acid environment. The specimens were subject to corrosion by immersion in acid solutions with different concentration. One hundred and twenty pullout specimens were used to study the effect of different environment on bond strength of GFRP and steel bars to concrete. Experimental results showed that, For GFRP bars, at the end of 75 days of conditioning duration, maximum bond strength loss of 11%, 22%, 17.2% and 14% were observed in tap water, pH = 2, pH = 3, and pH = 4 environment, respectively. For steel bars, at the end of 75 days of conditioning duration, maximum bond strength loss of 19.6% and 12.3% were observed in pH = 2 and pH = 3 environment, respectively. The influence of solution concentration on bond strength of GFRP bars was determined using Arrhenius equation and time shift method (TSF).

  9. Thermal analysis of GFRP-reinforced continuous concrete decks subjected to top fire

    Science.gov (United States)

    Hawileh, Rami A.; Rasheed, Hayder A.

    2017-12-01

    This paper presents a numerical study that investigates the behavior of continuous concrete decks doubly reinforced with top and bottom glass fiber reinforced polymer (GFRP) bars subjected to top surface fire. A finite element (FE) model is developed and a detailed transient thermal analysis is performed on a continuous concrete bridge deck under the effect of various fire curves. A parametric study is performed to examine the top cover thickness and the critical fire exposure curve needed to fully degrade the top GFRP bars while achieving certain fire ratings for the deck considered. Accordingly, design tables are prepared for each fire curve to guide the engineer to properly size the top concrete cover and maintain the temperature in the GFRP bars below critical design values in order to control the full top GFRP degradation. It is notable to indicate that degradation of top GFRP bars do not pose a collapse hazard but rather a serviceability concern since cracks in the negative moment region widen resulting in simply supported spans.

  10. Glass Fiber Reinforced Polymer (GFRP Bars for Enhancing the Flexural Performance of RC Beams Using Side-NSM Technique

    Directory of Open Access Journals (Sweden)

    Md. Akter Hosen

    2017-05-01

    Full Text Available Reinforced concrete (RC structures require strengthening for numerous factors, such as increased load, modification of the structural systems, structural upgrade or errors in the design and construction stages. The side near-surface mounted (SNSM strengthening technique with glass fiber-reinforced polymer (GFRP bars is a relatively new emerging technique for enhancing the flexural capacities of existing RC elements. Nine RC rectangular beams were flexurally strengthened with this technique and tested under four-point bending loads until failure. The main goal of this study is to optimize the structural capacity of the RC beams by varying the amount of strengthening reinforcement and bond length. The experimental test results showed that strengthening with SNSM GFRP bars significantly enhanced the flexural responses of the specimens compared with the control specimen. The first cracking and ultimate loads, energy absorption capacities, ductility and stiffness were remarkably enhanced by the SNSM technique. It was also confirmed that the bond length of the strengthened reinforcement greatly influences the energy absorption capacities, ductility and stiffness. The effect of the bond length on these properties is more significant compared to the amount of strengthening reinforcement.

  11. Finite Element Simulation of GFRP Reinforced Concrete Beam Externally Strengthened With CFRP Plates

    Directory of Open Access Journals (Sweden)

    Salleh Norhafizah

    2017-01-01

    Full Text Available The construction technology now has become more and more advanced allowing the development of new technologies or material to replace the previous one and also solved some of the troubles confronted by construction experts. The Glass Fibre Reinforced Polymer (GFRP composite is an alternative to replace the current usage of steel as it is rust proof and stronger in terms of stiffness compared to steel. Furthermore, GFRP bars have a high strength-to-weight ratio, making them attractive as reinforcement for concrete structures. However, the tensile behavior of GFRP bars is characterized by a linear elastic stress–strain relationship up to failure and, therefore, concrete elements reinforced with GFRP reinforcement exhibit brittle failure without warning. Design codes encourage over-reinforced GFRP design since it is more progressive and leads to a less catastrophic failure with a higher degree of deformability. Moreover, because of GFRP low modulus of elasticity, GFRP reinforced concrete members exhibit larger deflections and wider cracks width than steel reinforced concrete. This aims of this paper is to developed 2D Finite Element (FE models that can accurately simulate the respond on an improvement in the deflection of GFRP reinforced concrete beam externally strengthened with CFRP plates on the tension part of beam. The prediction of flexural response according to RCCSA software was also discussed. It was observed that the predicted FE results are given similar result with the experimental measured test data. Base on this good agreement, a parametric study was the performed using the validation FE model to investigate the effect of flexural reinforcement ratio and arrangement of the beams strengthened with different regions of CFRP plates.

  12. Residual Tensile Strength and Bond Properties of GFRP Bars after Exposure to Elevated Temperatures

    Directory of Open Access Journals (Sweden)

    Devon S. Ellis

    2018-02-01

    Full Text Available The use of fiber reinforced polymer (FRP bars in reinforced concrete members enhances corrosion resistance when compared to traditional steel reinforcing bars. Although there is ample research available on the behavior of FRP bars and concrete members reinforced with FRP bars under elevated temperatures (due to fire, there is little published information available on their post-fire residual load capacity. This paper reports residual tensile strength, modulus of elasticity, and bond strength (to concrete of glass fiber reinforced polymer (GFRP bars after exposure to elevated temperatures of up to 400 °C and subsequent cooling to an ambient temperature. The results showed that the residual strength generally decreases with increasing temperature exposure. However, as much as 83% of the original tensile strength and 27% of the original bond strength was retained after the specimens were heated to 400 °C and then cooled to ambient temperature. The residual bond strength is a critical parameter in post-fire strength assessments of GFRP-reinforced concrete members.

  13. Residual Tensile Strength and Bond Properties of GFRP Bars after Exposure to Elevated Temperatures.

    Science.gov (United States)

    Ellis, Devon S; Tabatabai, Habib; Nabizadeh, Azam

    2018-02-27

    The use of fiber reinforced polymer (FRP) bars in reinforced concrete members enhances corrosion resistance when compared to traditional steel reinforcing bars. Although there is ample research available on the behavior of FRP bars and concrete members reinforced with FRP bars under elevated temperatures (due to fire), there is little published information available on their post-fire residual load capacity. This paper reports residual tensile strength, modulus of elasticity, and bond strength (to concrete) of glass fiber reinforced polymer (GFRP) bars after exposure to elevated temperatures of up to 400 °C and subsequent cooling to an ambient temperature. The results showed that the residual strength generally decreases with increasing temperature exposure. However, as much as 83% of the original tensile strength and 27% of the original bond strength was retained after the specimens were heated to 400 °C and then cooled to ambient temperature. The residual bond strength is a critical parameter in post-fire strength assessments of GFRP-reinforced concrete members.

  14. Finite element modelling of concrete beams reinforced with hybrid fiber reinforced bars

    Science.gov (United States)

    Smring, Santa binti; Salleh, Norhafizah; Hamid, NoorAzlina Abdul; Majid, Masni A.

    2017-11-01

    Concrete is a heterogeneous composite material made up of cement, sand, coarse aggregate and water mixed in a desired proportion to obtain the required strength. Plain concrete does not with stand tension as compared to compression. In order to compensate this drawback steel reinforcement are provided in concrete. Now a day, for improving the properties of concrete and also to take up tension combination of steel and glass fibre-reinforced polymer (GFRP) bars promises favourable strength, serviceability, and durability. To verify its promise and support design concrete structures with hybrid type of reinforcement, this study have investigated the load-deflection behaviour of concrete beams reinforced with hybrid GFRP and steel bars by using ATENA software. Fourteen beams, including six control beams reinforced with only steel or only GFRP bars, were analysed. The ratio and the ordinate of GFRP to steel were the main parameters investigated. The behaviour of these beams was investigated via the load-deflection characteristics, cracking behaviour and mode of failure. Hybrid GFRP-Steel reinforced concrete beam showed the improvement in both ultimate capacity and deflection concomitant to the steel reinforced concrete beam. On the other hand, finite element (FE) modelling which is ATENA were validated with previous experiment and promising the good result to be used for further analyses and development in the field of present study.

  15. Long-Term Flexural Behaviors of GFRP Reinforced Concrete Beams Exposed to Accelerated Aging Exposure Conditions

    Directory of Open Access Journals (Sweden)

    Yeonho Park

    2014-06-01

    Full Text Available This study investigates the impact of accelerated aging conditions on the long-term flexural behavior and ductility of reinforced concrete (RC members with glass fiber-reinforced polymer (GFRP bars (RC-GFRP specimen and steel bars (RC-steel specimen. A total of thirty six specimens were designed with different amounts of reinforcement with three types of reinforcing bars (i.e., helically wrapped GFRP, sand-coated surface GFRP and steel. Eighteen specimens were subjected to sustained loads and accelerated aging conditions (i.e., 47 °C and 80% relative humidity in a chamber. The flexural behavior of specimens under 300-day exposure was compared to that of the companion specimens without experiencing accelerated aging conditions. Results indicate that the accelerated aging conditions reduced flexural capacity in not only RC-steel, but also RC-GFRP specimens, with different rates of reduction. Different types of GFRP reinforcement exhibited different rates of degradation of the flexural capacity when embedded in concrete under the same exposure conditions. Several existing models were compared with experimental results for predicting the deflection and deformability index for specimens. Bischoff and Gross’s model exhibited an excellent prediction of the time-dependent deflections. Except for the deformability index proposed by Jaeger, there was no general trend related to the aging duration. This study recommends the need for further investigation on the prediction of the deformability index.

  16. Strengthing of Beams and Columns using GFRP Bars

    Science.gov (United States)

    Nayak, C. B.; Tade, M. K.; Thakare, S. B., Dr.

    2017-08-01

    Nowadays infrastructure development is raising its pace. Many reinforced high concrete and masonry buildings are constructed annually around the globe. There are large numbers of structures which deteriorate or become unsafe to use because of changes in use, changes in loading condition, change in the design configuration, inferior building material used or natural calamities. Thus repairing and retrofitting of these structures for safe usage of has a great market. There are several situations in which a civil structure would require strengthening due to lack of strength, stiffness, ductility and durability. Beams, columns may be strengthened in flexure by using GFRP in tension zone. In this present work comparative study will be made with and without GFRP circular bars in a beam and column. An experiment study will be carried out to study the change in the structural behavior of beams & columns with GFRP circular bars of different thickness, varying span to depth ratio.

  17. Tensile Strength of GFRP Reinforcing Bars with Hollow Section

    Directory of Open Access Journals (Sweden)

    Young-Jun You

    2015-01-01

    Full Text Available Fiber reinforced polymer (FRP has been proposed to replace steel as a reinforcing bar (rebar due to its high tensile strength and noncorrosive material properties. One obstacle in using FRP rebars is high price. Generally FRP is more expensive than conventional steel rebar. There are mainly two ways to reduce the cost. For example, one is making the price of each composition cost of FRP rebar (e.g., fibers, resin, etc. lower than steel rebar. Another is making an optimized design for cross section and reducing the material cost. The former approach is not easy because the steel price is very low in comparison with component materials of FRP. For the latter approach, the cost could be cut down by reducing the material cost. Therefore, an idea of making hollow section over the cross section of FRP rebar was proposed in this study by optimizing the cross section design with acceptable tensile performance in comparison with steel rebar. In this study, glass reinforced polymer (GFRP rebars with hollow section and 19 mm of outer diameter were manufactured and tested to evaluate the tensile performance in accordance with the hollowness ratio. From the test results, it was observed that the tensile strength decreased almost linearly with increase of hollowness ratio and the elastic modulus decreased nonlinearly.

  18. A Modified Model for Deflection Calculation of Reinforced Concrete Beam with Deformed GFRP Rebar

    Directory of Open Access Journals (Sweden)

    Minkwan Ju

    2016-01-01

    Full Text Available The authors carried out experimental and analytical research to evaluate the flexural capacity and the moment-deflection relationship of concrete beams reinforced with GFRP bars. The proposed model to predict the effective moment of inertia for R/C beam with GFRP bars was developed empirically, based on Branson’s equation to have better accuracy and a familiar approach to a structural engineer. For better prediction of the moment-deflection relationship until the ultimate strength is reached, a nonlinear parameter (k was also considered. This parameter was introduced to reduce the effect of the cracked moment of inertia for the reinforced concrete member, including a lower reinforcement ratio and modulus of elasticity of the GFRP bar. In a comparative study using six equations suggested by others, the proposed model showed better agreement with the experimental test results. It was confirmed that the empirical modification based on Branson’s equation was valid for predicting the effective moment of inertia of R/C beams with GFRP bar in this study. To evaluate the generality of the proposed model, a comparative study using previous test results from the literature and the results from this study was carried out. It was found that the proposed model had better accuracy and was a familiar approach to structural engineers to predict and evaluate the deflection behavior.

  19. A Modified Model for Deflection Calculation of Reinforced Concrete Beam with Deformed GFRP Rebar

    OpenAIRE

    Ju, Minkwan; Oh, Hongseob; Lim, Junhyun; Sim, Jongsung

    2016-01-01

    The authors carried out experimental and analytical research to evaluate the flexural capacity and the moment-deflection relationship of concrete beams reinforced with GFRP bars. The proposed model to predict the effective moment of inertia for R/C beam with GFRP bars was developed empirically, based on Branson’s equation to have better accuracy and a familiar approach to a structural engineer. For better prediction of the moment-deflection relationship until the ultimate strength is reached,...

  20. Long-term performance of GFRP reinforcement : technical report.

    Science.gov (United States)

    2009-12-01

    Significant research has been performed on glass fiber-reinforced polymer (GFRP) concrete reinforcement. : This research has shown that GFRP reinforcement exhibits high strengths, is lightweight, can decrease time of : construction, and is corrosion ...

  1. PERFORMANCE OF RC AND FRC WALL PANELS REINFORCED WITH MILD STEEL AND GFRP COMPOSITES IN BLAST EVENTS

    Energy Technology Data Exchange (ETDEWEB)

    Timothy Garfield; William D. Richins; Thomas K. Larson; Chris P. Pantelides; James E. Blakeley

    2011-06-01

    The structural integrity of reinforced concrete structures in blast events is important for critical facilities. This paper presents experimental data generated for calibrating detailed finite element models that predict the performance of reinforced concrete wall panels with a wide range of construction details under blast loading. The test specimens were 1.2 m square wall panels constructed using Normal Weight Concrete (NWC) or Fiber Reinforced Concrete (FRC). FRC consists of macro-synthetic fibers dispersed in NWC. Five types of panels were tested: NWC panels with steel bar reinforcement (Type A); FRC panels without additional reinforcement (Type B); FRC panels with steel bar reinforcement (Type C); NWC panels with glass fiber reinforced polymer (GFRP) bar reinforcement (Type D); and NWC panels reinforced with steel bar reinforcement and external bidirectional GFRP overlays on both faces (Type E). An additional three Type C panels were used as control specimens (CON). Each panel type was constructed with three thicknesses: 152 mm, 254 mm, and 356 mm. The panels were instrumented with strain gauges, and accelerometers; in addition, pressure sensors and high speed videos were employed during the blast events. Panel types C and E had the best performance, whereas panel type B did not perform well. Preliminary dynamic simulations show crack patterns similar to the experimental results.

  2. Non-traditional shape GFRP rebars for concrete reinforcement

    Science.gov (United States)

    Claure, Guillermo G.

    The use of glass-fiber-reinforced-polymer (GFRP) composites as internal reinforcement (rebars) for concrete structures has proven to be an alternative to traditional steel reinforcement due to significant advantages such as magnetic transparency and, most importantly, corrosion resistance equating to durability and structural life extension. In recent years, the number of projects specifying GFRP reinforcement has increased dramatically leading the construction industry towards more sustainable practices. Typically, GFRP rebars are similar to their steel counterparts having external deformations or surface enhancements designed to develop bond to concrete, as well as having solid circular cross-sections; but lately, the worldwide composites industry has taken advantage of the pultrusion process developing GFRP rebars with non-traditional cross-sectional shapes destined to optimize their mechanical, physical, and environmental attributes. Recently, circular GFRP rebars with a hollow-core have also become available. They offer advantages such as a larger surface area for improved bond, and the use of the effective cross-sectional area that is engaged to carry load since fibers at the center of a solid cross-section are generally not fully engaged. For a complete understanding of GFRP rebar physical properties, a study on material characterization regarding a quantitative cross-sectional area analysis of different GFRP rebars was undertaken with a sample population of 190 GFRP specimens with rebar denomination ranging from #2 to #6 and with different cross-sectional shapes and surface deformations manufactured by five pultruders from around the world. The water displacement method was applied as a feasible and reliable way to conduct the investigation. In addition to developing a repeatable protocol for measuring cross-sectional area, the objectives of establishing critical statistical information related to the test methodology and recommending improvements to

  3. Flexural Behavior of GFRP Tubes Filled with Magnetically Driven Concrete.

    Science.gov (United States)

    Xie, Fang; Chen, Ju; Dong, Xinlong; Feng, Bing

    2018-01-08

    Experimental investigation of GFRP (glass fiber reinforced polymer) tubes that were filled with magnetically driven concrete was carried out to study the flexural behavior of specimens under bending. Specimens having different cross section and lengths were tested. The test specimens were fabricated by filling magnetically driven concrete into the GFRP tubes and the concrete was vibrated using magnetic force. Specimens vibrated using vibrating tube were also tested for comparison. In addition, specimens having steel reinforcing bars and GFRP bars were both tested to study the effect of reinforcing bars on the magnetically driven concrete. The load-displacement curves, load-strain curves, failure mode, and ultimate strengths of test specimens were obtained. Design methods for the flexural stiffness of test specimens were also discussed in this study.

  4. Strengthening Reinforced Concrete Beams with CFRP and GFRP

    Directory of Open Access Journals (Sweden)

    Mehmet Mustafa Önal

    2014-01-01

    Full Text Available Concrete beams were strengthened by wrapping the shear edges of the beams twice at 45° in opposite directions by either carbon fiber reinforced polymer (CFRP or glass fiber reinforced polymer (GFRP. The study included 3 CFRP wrapped beams, 3 GFRP wrapped beams, and 3 control beams, all of which were 150 × 250 × 2200 mm and manufactured with C20 concrete and S420a structural steel at the Gazi University Technical Education Faculty labs, Turkey. Samples in molds were cured by watering in the open air for 21 days. Four-point bending tests were made on the beam test specimens and the data were collected. Data were evaluated in terms of load displacement, bearing strength, ductility, and energy consumption. In the CFRP and GFRP reinforced beams, compared to controls, 38% and 42%, respectively, strength increase was observed. In all beams, failure-flexural stress occurred in the center as expected. Most cracking was observed in the flexural region 4. A comparison of CFRP and GFRP materials reveals that GFRP enforced parts absorb more energy. Both materials yielded successful results. Thicker epoxy application in both CFRP and GFRP beams was considered to be effective in preventing break-ups.

  5. Experimental Investigation for Tensile Performance of GFRP-Steel Hybridized Rebar

    Directory of Open Access Journals (Sweden)

    Dong-Woo Seo

    2016-01-01

    Full Text Available Tensile performance of the recently developed “FRP Hybrid Bar” at Korea Institute of Civil Engineering and Building Technology (KICT is experimentally evaluated by the authors. FRP Hybrid Bar is introduced to overcome the low elastic modulus of the existing GFRP bars to be used as a structural member in reinforced concrete structures. The concept of material hybridization is applied to increase elastic modulus of GFRP bars by using steel. This hybridized GFRP bar can be used in concrete structures as a flexural reinforcement with a sufficient level of elastic modulus. In order to verify the effect of material hybridization on tensile properties, tensile tests are conducted. The test results for both FRP Hybrid Bar and the existing GFRP bars are compared. The results indicate that the elastic modulus of FRP Hybrid Bar can be enhanced by up to approximately 250 percent by the material hybridization with a sufficient tensile strength. To ensure the long-term durability of FRP Hybrid Bar to corrosion resistance, the individual and combined effects of environmental conditions on FRP Hybrid Bar itself as well as on the interface between rebar and concrete are currently under investigation.

  6. Creep investigation of GFRP RC Beams - Part A : Literature review and experimental Study

    Directory of Open Access Journals (Sweden)

    masmoudi abdelmonem

    2014-11-01

    This paper (Part A presents a literature review and the loading history of six experimental beams reinforced with GFRP and steel bars. The results of this study revealed that Beams reinforced with GFRP are less marked with creep phenomenon.  This investigation should guide the civil engineer/designer for a better understanding creep phenomenon in GFRP reinforced concrete members.

  7. Finite element analysis of GFRP reinforced concrete pavement under static load

    Science.gov (United States)

    Li, Shiping; Hu, Chunhua

    2018-02-01

    GFRP was more corrosion resistant than traditional reinforced, it is lightweight, high strength thermal expansion coefficient is more close to the concrete and a poor conductor of electromagnetic. Therefore, the use of GFRP to replace the traditional reinforcement in concrete pavement application has excellent practical value. This paper uses ANSYS to establish delamination and reinforcement of Pavement model and analyzed response of GFRP concrete and ordinary concrete pavement structural mechanics on effects of different factors under the action of static. The results showed that under static load, pavement surface layer presented similar changes on stress of surface layer, vertical and horizontal deformation in two kinds of pavement structure, but indicators of GFRP reinforced concrete pavement were obviously better than that of ordinary concrete pavement.

  8. Cracking and Strain Analysis of Beams Reinforced with Composite Bars

    Directory of Open Access Journals (Sweden)

    Edgaras Timinskas

    2012-11-01

    Full Text Available The paper discusses the results of experimental and numerical modelling using two beams reinforced with GFRP bars. One beam was made of plain concrete while the other contained short steel fibres. The influence of steel fibres on deflection and cracking behaviour was studied. A comparative analysis of experimental results has shown that steel fibres significantly reduce deflections and average crack width of the beam. Moreover, an addition of steel fibres to the concrete mix led to a more ductile failure mode of the beam. Numerical analysis employing nonlinear finite element software ATENA has revealed that a good agreement between calculated and experimental results regarding an ordinary concrete GFRP reinforced beam can be obtained.

  9. Structural Behavior of Concrete Beams Reinforced with Basalt Fiber Reinforced Polymer (BFRP) Bars

    Science.gov (United States)

    Ovitigala, Thilan

    The main challenge for civil engineers is to provide sustainable, environmentally friendly and financially feasible structures to the society. Finding new materials such as fiber reinforced polymer (FRP) material that can fulfill the above requirements is a must. FRP material was expensive and it was limited to niche markets such as space shuttles and air industry in the 1960s. Over the time, it became cheaper and spread to other industries such as sporting goods in the 1980-1990, and then towards the infrastructure industry. Design and construction guidelines are available for carbon fiber reinforced polymer (CFRP), aramid fiber reinforced polymer (AFRP) and glass fiber reinforced polymer (GFRP) and they are currently used in structural applications. Since FRP is linear elastic brittle material, design guidelines for the steel reinforcement are not valid for FRP materials. Corrosion of steel reinforcement affects the durability of the concrete structures. FRP reinforcement is identified as an alternative to steel reinforcement in corrosive environments. Although basalt fiber reinforced polymer (BFRP) has many advantages over other FRP materials, but limited studies have been done. These studies didn't include larger BFRP bar diameters that are mostly used in practice. Therefore, larger beam sizes with larger BFRP reinforcement bar diameters are needed to investigate the flexural and shear behavior of BFRP reinforced concrete beams. Also, shear behavior of BFRP reinforced concrete beams was not yet studied. Experimental testing of mechanical properties and bond strength of BFRP bars and flexural and shear behavior of BFRP reinforced concrete beams are needed to include BFRP reinforcement bars in the design codes. This study mainly focuses on the use of BFRP bars as internal reinforcement. The test results of the mechanical properties of BFRP reinforcement bars, the bond strength of BFRP reinforcement bars, and the flexural and shear behavior of concrete beams

  10. Experimental Study On Flexural Behaviour Of Beams Reinforced With GFRP Rebars

    Science.gov (United States)

    Naveen Kumar, G.; Sundaravadivelu, Karthik

    2017-07-01

    In saline, moisture and cold conditions corrosion of steel is inevitable and the lot of economy is used for rehabilitation works. Corrosion of steel is nothing but oxidation of iron in moisture conditions and this corrosion leads to the spalling of concrete which intern reduces the strength of the structure. To reduce this corrosion effects, new materials with resistance against corrosion have to be introduced. Many experiments are going on using Glass Fiber Reinforced Polymer (GFRP) as alternate material for steel due to its non-corrosive nature, weight of GFRP is nearly one third of steel and ultimate tensile strength is higher than steel. In this paper, six beams are casted in which three beams are casted with steel as main and shear reinforcement and another three beams are casted with GFRP as main reinforcement with steel as shear reinforcing material. All beams casted are of same dimensions with variation in reinforcement percentage. The size of the beams casted is of length 1200 mm, breadth 100 mm and depth 200 mm. The clear cover of 25 mm is provided on top and bottom of the beam. Beams are tested under two-point loading with constant aspect ratio (a/d) and comparing the flexural strength, load deflection curves and types of failures of beams reinforced with GFRP as main reinforcement and beams reinforced with conventional steel. The final experimental results are compared with numerical results. M30 grade concrete with Conplast as a superplasticizer is used for casting beams.

  11. Flexural strengthening of Reinforced Concrete (RC) Beams Retrofitted with Corrugated Glass Fiber Reinforced Polymer (GFRP) Laminates

    Science.gov (United States)

    Aravind, N.; Samanta, Amiya K.; Roy, Dilip Kr. Singha; Thanikal, Joseph V.

    2015-01-01

    Strengthening the structural members of old buildings using advanced materials is a contemporary research in the field of repairs and rehabilitation. Many researchers used plain Glass Fiber Reinforced Polymer (GFRP) sheets for strengthening Reinforced Concrete (RC) beams. In this research work, rectangular corrugated GFRP laminates were used for strengthening RC beams to achieve higher flexural strength and load carrying capacity. Type and dimensions of corrugated profile were selected based on preliminary study using ANSYS software. A total of twenty one beams were tested to study the load carrying capacity of control specimens and beams strengthened with plain sheets and corrugated laminates using epoxy resin. This paper presents the experimental and theoretical study on flexural strengthening of Reinforced Concrete (RC) beams using corrugated GFRP laminates and the results are compared. Mathematical models were developed based on the experimental data and then the models were validated.

  12. Review of Punching Shear Behaviour of Flat Slabs Reinforced with FRP Bars

    Science.gov (United States)

    Mohamed, Osama A.; Khattab, Rania

    2017-10-01

    Using Fibre Reinforced Polymer (FRP) bars to reinforce two-way concrete slabs can extend the service life, reduce maintenance cost and improve-life cycle cost efficiency. FRP reinforcing bars are more environmentally friendly alternatives to traditional reinforcing steel. Shear behaviour of reinforced concrete structural members is a complex phenomenon that relies on the development of internal load-carrying mechanisms, the magnitude and combination of which is still a subject of research. Many building codes and design standards provide design formulas for estimation of punching shear capacity of FRP reinforced flat slabs. Building code formulas take into account the effects of the axial stiffness of main reinforcement bars, the ratio of the perimeter of the critical section to the slab effective depth, and the slab thickness on the punching shear capacity of two-way slabs reinforced with FRP bars or grids. The goal of this paper is to compare experimental data published in the literature to the equations offered by building codes for the estimation of punching shear capacity of concrete flat slabs reinforced with FRP bars. Emphasis in this paper is on two North American codes, namely, ACI 440.1R-15 and CSA S806-12. The experimental data covered in this paper include flat slabs reinforced with GFRP, BFRP, and CFRP bars. Both ACI 440.1R-15 and CSA S806-12 are shown to be in good agreement with test results in terms of predicting the punching shear capacity.

  13. Strain measurement in a concrete beam by use of the Brillouin-scattering-based distributed fiber sensor with single-mode fibers embedded in glass fiber reinforced polymer rods and bonded to steel reinforcing bars.

    Science.gov (United States)

    Zeng, Xiaodong; Bao, Xiaoyi; Chhoa, Chia Yee; Bremner, Theodore W; Brown, Anthony W; DeMerchant, Michael D; Ferrier, Graham; Kalamkarov, Alexander L; Georgiades, Anastasis V

    2002-08-20

    The strain measurement of a 1.65-m reinforced concrete beam by use of a distributed fiber strain sensor with a 50-cm spatial resolution and 5-cm readout resolution is reported. The strain-measurement accuracy is +/-15 microepsilon (microm/m) according to the system calibration in the laboratory environment with non-uniform-distributed strain and +/-5 microepsilon with uniform strain distribution. The strain distribution has been measured for one-point and two-point loading patterns for optical fibers embedded in pultruded glass fiber reinforced polymer (GFRP) rods and those bonded to steel reinforcing bars. In the one-point loading case, the strain deviations are +/-7 and +/-15 microepsilon for fibers embedded in the GFRP rods and fibers bonded to steel reinforcing bars, respectively, whereas the strain deviation is +/-20 microepsilon for the two-point loading case.

  14. Flexural strength using Steel Plate, Carbon Fiber Reinforced Polymer (CFRP) and Glass Fiber Reinforced Polymer (GFRP) on reinforced concrete beam in building technology

    Science.gov (United States)

    Tarigan, Johannes; Patra, Fadel Muhammad; Sitorus, Torang

    2018-03-01

    Reinforced concrete structures are very commonly used in buildings because they are cheaper than the steel structures. But in reality, many concrete structures are damaged, so there are several ways to overcome this problem, by providing reinforcement with Fiber Reinforced Polymer (FRP) and reinforcement with steel plates. Each type of reinforcements has its advantages and disadvantages. In this study, researchers discuss the comparison between flexural strength of reinforced concrete beam using steel plates and Fiber Reinforced Polymer (FRP). In this case, the researchers use Carbon Fiber Reinforced Polymer (CFRP) and Glass Fiber Reinforced Polymer (GFRP) as external reinforcements. The dimension of the beams is 15 x 25 cm with the length of 320 cm. Based on the analytical results, the strength of the beam with CFRP is 1.991 times its initial, GFRP is 1.877 times while with the steel plate is 1.646 times. Based on test results, the strength of the beam with CFRP is 1.444 times its initial, GFRP is 1.333 times while the steel plate is 1.167 times. Based on these test results, the authors conclude that beam with CFRP is the best choice for external reinforcement in building technology than the others.

  15. Articularities of Analysis and Behaviour of Concrete Beams Reinforced with Fibrous Polymer Composite Bars

    Directory of Open Access Journals (Sweden)

    N. Ţăranu

    2006-01-01

    Full Text Available Traditional steel based reinforcement systems for concrete elements are facing with serious problems mainly caused by corrosion due to chemically aggressive environments and salts used in deicing procedures, especially in case of bridge steel reinforced concrete girders. Also in some cases special applications require structural members with magnetic transparency. An alternative to this major problem has recently become the use of fiber reinforced polymer (FPR composite bars as internal reinforcement for concrete beams. The particularities of their mechanical properties are making the design process a difficult task for engineers, numerous research centers being involved in correcting this situation. The general aspects concerning the conceiving of FR.P reinforced concrete beams are firstly analyzed, compared to those reinforced with steel bars. Some results of a Finite Element Analysis, as part of a complex program which also implies full scale testing of FRP reinforced beams subjected to bending, are given and discussed in the paper. The low elasticity modulus presented by glass fiber reinforced polymer (GFRP bars does not justify its use from structural point of view when deflection is the limiting condition but for corrosive resistance reasons and special electromagnetic properties this system can be promoted.

  16. Influence of SMA reinforcement on the impact resistance of GFRP ...

    Indian Academy of Sciences (India)

    composite laminates under different temperatures ... GFRP laminates; shape memory alloy; low velocity impact; impact resistance; SEM. ... 25 J) with the temperature range of 50–120 ... C. The fibre used as reinforcement was S-type glass fibre.

  17. Finite Element Modeling of GFRP-Reinforced Concrete Interior Slab-Column Connections Subjected to Moment Transfer

    Directory of Open Access Journals (Sweden)

    Ahmed Gouda

    2015-10-01

    Full Text Available A finite element model (FEM was constructed using specialized three-dimensional (3D software to investigate the punching shear behavior of interior slab-column connections subjected to a moment-to-shear ratio of 0.15 m. The FEM was then verified against the experimental results of full-scale interior slab-column connections reinforced with glass fiber reinforcement polymer (GFRP bars previously tested by the authors. The FEM results showed that the constructed model was able to predict the behavior of the slabs with reasonable accuracy. Afterward, the verified model was used to conduct a parametric study to investigate the effects of reinforcement ratio, perimeter-to-depth ratio, and column aspect ratio on the punching shear behavior of such connections. The test results showed that increasing the tested parameters enhanced the overall behavior of the connections in terms of decreasing deflections and reinforcement strain and increasing the ultimate capacity. In addition, the obtained punching shear stresses of the connections were compared to the predictions of the Canadian standard and the American guideline for FRP-reinforced concrete structures.

  18. Improving Fatigue Performance of GFRP Composite Using Carbon Nanotubes

    Directory of Open Access Journals (Sweden)

    Moneeb Genedy

    2015-01-01

    Full Text Available Glass fiber reinforced polymers (GFRP have become a preferable material for reinforcing or strengthening reinforced concrete structures due to their corrosion resistance, high strength to weight ratio, and relatively low cost compared with carbon fiber reinforced polymers (CFRP. However, the limited fatigue life of GFRP hinders their use in infrastructure applications. For instance, the low fatigue life of GFRP caused design codes to impose stringent stress limits on GFRP that rendered their use non-economic under significant cyclic loads in bridges. In this paper, we demonstrate that the fatigue life of GFRP can be significantly improved by an order of magnitude by incorporating Multi-Wall Carbon Nanotubes (MWCNTs during GFRP fabrication. GFRP coupons were fabricated and tested under static tension and cyclic tension with mean fatigue stress equal to 40% of the GFRP tensile strength. Microstructural investigations using scanning electron microscopy (SEM and Fourier Transform Infrared (FTIR spectroscopy were used for further investigation of the effect of MWCNTs on the GFRP composite. The experimental results show the 0.5 wt% and the 1.0 wt% MWCNTs were able to improve the fatigue life of GFRP by 1143% and 986%, respectively, compared with neat GFRP.

  19. Experimental Investigation of the Effects of Concrete Alkalinity on Tensile Properties of Preheated Structural GFRP Rebar

    Directory of Open Access Journals (Sweden)

    Hwasung Roh

    2017-01-01

    Full Text Available The combined effects of preexposure to high temperature and alkalinity on the tensile performance of structural GFRP reinforcing bars are experimentally investigated. A total of 105 GFRP bar specimens are preexposed to high temperature between 120°C and 200°C and then immersed into pH of 12.6 alkaline solution for 100, 300, and 660 days. From the test results, the elastic modulus obtained at 300 immersion days is almost the same as those of 660 immersion days. For all alkali immersion days considered in the test, the preheated specimens provide slightly lower elastic modulus than the unpreheated specimens, showing only 8% maximum difference. The tensile strength decreases for all testing cases as the increase of the alkaline immersing time, regardless of the prehearing levels. The tensile strength of the preheated specimens is about 90% of the unpreheated specimen for 300 alkali immersion days. However, after 300 alkali immersion days the tensile strengths are almost identical to each other. Such results indicate that the tensile strength and elastic modulus of the structural GFRP reinforcing bars are closely related to alkali immersion days, not much related to the preheating levels. The specimens show a typical tensile failure around the preheated location.

  20. Flexural reinforced concrete member with FRP reinforcement

    OpenAIRE

    Putzolu, Mariana

    2017-01-01

    One of the most problematic point in construction is the durability of the concrete especially related to corrosion of the steel reinforcement. Due to this problem the construction sector, introduced the use of Fiber Reinforced Polymer, the main fibers used in construction are Glass, Carbon and Aramid. In this study, the author aim to analyse the flexural behaviour of concrete beams reinforced with FRP. This aim is achieved by the analysis of specimens reinforced with GFRP bars, with theoreti...

  1. Reinforcement of Bolted Timber Joints Using GFRP Sheets in Poplar and Pine Woods

    Directory of Open Access Journals (Sweden)

    Mehrab Madhoushi

    2013-01-01

    Full Text Available Failure in timber structures occurs mainly in crucial points such as joints areas. Therefore, the idea of using composite sheets in timber joints has been intro-duced as a method in order to increase the strength and ductility behaviour of timber joints. This research aims to study the behaviour of bolted joints in poplar and pine woods, which are reinforced by two types of GFRP sheets. A single shear bolted joint consisted of 3 timber members whose length and width were 30 cm in length and 5 cm in width. The thickness of each member was 4 cm for internal part and 2 cm for external part. The employed steel bolt was 10 cm in length and 1 cm in diameter. In this respect, one layer of GFRP sheet was used to be bonded to timber members by using epoxy resin and left between the clamps for 24 hours. They were then kept at room temperature for three weeks. Also the effect of adding a wood veneer on the reinforced joints was investigated. The tensile strength of the reinforced and control samples (un-reinforced joints was measured according to ASTM D5652-92 standard. The results show that the reinforced samples have higher tensile strength compared to that of reinforced joints, although it is not statistically signifcant. Also, two types of sheets infuence the joint behaviour as the reinforced joints display more ductility behaviour.

  2. Influence of specimen type and reinforcement on measured tension-tension fatigue life of unidirectional GFRP laminates

    DEFF Research Database (Denmark)

    Korkiakoski, Samuli; Brøndsted, Povl; Sarlin, Essi

    2016-01-01

    It is well known that standardised tension-tension fatigue test specimens of unidirectional (UD) glass-fibre-reinforced plastics (GFRP) laminates tend to fail at end tabs. The true fatigue life is then underestimated. The first objective of this study was to find for UD GFRP laminates a test...... specimen that fails in the gauge section. The second objective was to compare fatigue performance of two laminates, one having a newly developed UD powder-bound fabric as a reinforcement and the other having a quasi-UD stitched non-crimp fabric as a reinforcement. In the first phase, a rectangular specimen...... in accordance with the ISO 527-5 standard and two slightly different dog-bone shaped specimens were evaluated by means of finite element modelling. Subsequent comparative fatigue tests were performed for the laminates with the three specimen types. The results showed that the test specimen type has...

  3. Composite Behavior of a Novel Insulated Concrete Sandwich Wall Panel Reinforced with GFRP Shear Grids: Effects of Insulation Types.

    Science.gov (United States)

    Kim, JunHee; You, Young-Chan

    2015-03-03

    A full-scale experimental program was used in this study to investigate the structural behavior of novel insulated concrete sandwich wall panels (SWPs) reinforced with grid-type glass-fiber-reinforced polymer (GFRP) shear connectors. Two kinds of insulation-expanded polystyrene (EPS) and extruded polystyrene (XPS) with 100 mm thickness were incased between the two concrete wythes to meet the increasing demand for the insulation performance of building envelope. One to four GFRP shear grids were used to examine the degree of composite action of the two concrete wythes. Ten specimens of SWPs were tested under displacement control subjected to four-point concentrated loads. The test results showed that the SWPs reinforced with GFRP grids as shear connectors developed a high degree of composite action resulting in high flexural strength. The specimens with EPS foam exhibited an enhanced load-displacement behavior compared with the specimens with XPS because of the relatively stronger bond between insulation and concrete. In addition, the ultimate strength of the test results was compared to the analytical prediction with the mechanical properties of only GRFP grids. The specimens with EPS insulation presented higher strength-based composite action than the ones with XPS insulation.

  4. The properties degradation of exposed GFRP roof

    Science.gov (United States)

    Zainudin, Mohammad; Diharjo, Kuncoro; Kaavessina, Mujtahid; Setyanto, Djoko

    2018-02-01

    There is much consideration of roof selection as a protector of a building against the outside weather, such as lightweight, strong stiff, corrosion resistant and guarantee for the availability of products. Based on these considerations, glass fiber reinforced polymer (GFRP) roof is a roof which can fulfill the requirement. The objective of this research is to investigate the degradation of physical and mechanical properties of GFRP roof exposed in outside weather. This GFRP roof composite was produced using a sheet molding compound (SMC) supplied by PT Intec Persada, Tangerang, Indonesia. There are two kinds GFRP roofs evaluated in this research that are GFRP roof exposed within 7 years and new GFRP roof that has not been exposed. The GFRP roofs were cut manually for preparing the specimens for hardness test, tensile test, SEM and FTIR test. The results show that the GFRP roof exposed within 7 years had the degradation of properties compared to the new GFRP roof. The exposed GFRP roof had lower strength and hardness compared to the new GFRP roof. The SEM observation indicates that exposed GFRP roof had the debonding of fiber on the surface, and in contrast, there are no debonding of fiber in the new GFRP roof surface. It can be recommended that the exposed GFRP roof may be repaired to enhance its performance and can re-increase its properties using the coating.

  5. Modification of Rule of Mixtures for Tensile Strength Estimation of Circular GFRP Rebars

    Directory of Open Access Journals (Sweden)

    Young-Jun You

    2017-12-01

    Full Text Available The rule of mixtures (ROM method is often used to estimate the tensile strength of fiber reinforced polymers (FRPs reinforcing bars (rebars. Generally, the ROM method predicts the FRP rebars’ modulus of elasticity adequately but overestimates their tensile strength. This may result from defects occurred during manufacture that prevent the used materials from exhibiting a sound performance and the shear-lag phenomenon by transmission of external forces through the surface of the rebar having a circular cross section. Due to the latter, there is a difference in fiber breaking points regarding the fibers located on the surface and fibers located at the center, and thus results in differences between the values calculated from the conventional ROM and the experimental result. In this study, for the purpose of resolving the problem, glass FRP (GFRP rebars were shaped to have a hollow section at the center of their cross sections and were further subject to tensile strength tests. The test results were further placed under regression analysis and a modified ROM within ±5% accuracy compared to the experimental value was proposed for GFRP rebars with 13, 16, and 19 mm diameters.

  6. Shear Strengthening of RC Deep Beam Using Externally Bonded GFRP Fabrics

    Science.gov (United States)

    Kumari, A.; Patel, S. S.; Nayak, A. N.

    2018-06-01

    This work presents the experimental investigation of RC deep beams wrapped with externally bonded Glass Fibre Reinforced Polymer (GFRP) fabrics in order to study the Load versus deflection behavior, cracking pattern, failure modes and ultimate shear strength. A total number of five deep beams have been casted, which is designed with conventional steel reinforcement as per IS: 456 (Indian standard plain and reinforced concrete—code for practice, Bureau of Indian Standards, New Delhi, 2000). The spans to depth ratio for all RC deep beams have been kept less than 2 as per the above specification. Out of five RC deep beams, one without retrofitting serves as a reference beam and the rest four have been wrapped with GFRP fabrics in multiple layers and tested with two point loading condition. The first cracking load, ultimate load and the shear contribution of GFRP to the deep beams have been observed. A critical discussion is made with respect to the enhancement of the strength, behaviour and performance of retrofitted deep beams in comparison to the deep beam without GFRP in order to explore the potential use of GFRP for strengthening the RC deep beams. Test results have demonstrated that the deep beams retrofitted with GFRP shows a slower development of the diagonal cracks and improves shear carrying capacity of the RC deep beam. A comparative study of the experimental results with the theoretical ones predicted by various researchers available in the literatures has also been presented. It is observed that the ultimate load of the beams retrofitted with GFRP fabrics increases with increase of number of GFRP layers up to a specific number of layers, i.e. 3 layers, beyond which it decreases.

  7. Mechanical Properties of Welded Deformed Reinforcing Steel Bars

    Directory of Open Access Journals (Sweden)

    Ghafur H. Ahmed

    2015-05-01

    Full Text Available Reinforcement strength, ductility and bendability properties are important components in design of reinforced concrete members, as the strength of any member comes mainly from reinforcement. Strain compatibility and plastic behaviors are mainly depending on reinforcement ductility. In construction practice, often welding of the bars is required. Welding of reinforcement is an instant solution in many cases, whereas welding is not a routine connection process. Welding will cause deficiencies in reinforcement bars, metallurgical changes and re-crystallization of microstructure of particles. Weld metal toughness is extremely sensitive to the welding heat input that decreases both of its strength and ductility. For determining the effects of welding in reinforcement properties, 48 specimens were tested with 5 different bar diameters, divided into six groups. Investigated parameters were: properties of un-welded bars; strength, ductility and density of weld metal; strength and ductility reduction due to heat input for bundled bars and transverse bars; welding effect on bars’ bending properties; behavior of different joint types; properties of three weld groove shapes also the locations and types of failures sections. Results show that, strength and elongation of the welded bars decreased by (10-40% and (30-60% respectively. Cold bending of welded bars and groove welds shall be prevented.

  8. Numerical estimation of concrete beams reinforced with FRP bars

    Directory of Open Access Journals (Sweden)

    Protchenko Kostiantyn

    2016-01-01

    Full Text Available This paper introduces numerical investigation on mechanical performance of a concrete beam reinforced with Fibre Reinforced Polymer (FRP bars, which can be competitive alternative to steel bars for enhancing concrete structures. The objective of this work is being identified as elaborating of reliable numerical model for predicting strength capacity of structural elements with implementation of Finite Element Analysis (FEA. The numerical model is based on experimental study prepared for the beams, which were reinforced with Basalt FRP (BFRP bars and steel bars (for comparison. The results obtained for the beams reinforced with steel bars are found to be in close agreement with the experimental results. However, the beams reinforced with BFRP bars in experimental programme demonstrated higher bearing capacity than those reinforced with steel bars, which is not in a good convergence with numerical results. Authors did attempt to describe the reasons on achieving experimentally higher bearing capacity of beams reinforced with BFRP bars.

  9. Bond slip and crack development in FRC and regular concrete specimens longitudinally reinforced with FRP or steel under tension loading

    DEFF Research Database (Denmark)

    Lárusson, Lárus Helgi; Fischer, Gregor

    2012-01-01

    tensile loading using high definition image analysis in two unique test setups. Two different types of cementitious materials, conventional concrete and highly ductile Engineered Cementitious Composite (ECC), and two types of reinforcement bars, regular steel and Glass Fiber Reinforcement Polymer (GFRP......The governing mechanism in the structural response of reinforced concrete members in tension is the interaction between structural reinforcement and the surrounding concrete matrix. The composite response and the mechanical integrations of reinforced cementitious members were investigated during......), were tested. It was found that the ductile ECC in contrast to regular brittle concrete decreases crack widths significantly which effectively results in decreased bond slip between the reinforcement and surrounding matrix. Furthermore the use of elastic GFRP in comparison to elastic/plastic steel...

  10. Monitoring Moisture Damage Propagation in GFRP Composites Using Carbon Nanoparticles

    Directory of Open Access Journals (Sweden)

    Ahmed Al-Sabagh

    2017-03-01

    Full Text Available Glass fiber reinforced polymer (GFRP composites are widely used in infrastructure applications including water structures due to their relatively high durability, high strength to weight ratio, and non-corrosiveness. Here we demonstrate the potential use of carbon nanoparticles dispersed during GFRP composite fabrication to reduce water absorption of GFRP and to enable monitoring of moisture damage propagation in GFRP composites. GFRP coupons incorporating 2.0 wt % carbon nanofibers (CNFs and 2.0 wt % multi-wall carbon nanotubes (MWCNTs were fabricated in order to study the effect of moisture damage on mechanical properties of GFRP. Water absorption tests were carried out by immersing the GFRP coupons in a seawater bath at two temperatures for a time period of three months. Effects of water immersion on the mechanical properties and glass transition temperature of GFRP were investigated. Furthermore, moisture damage in GFRP was monitored by measuring the electrical conductivity of the GFRP coupons. It was shown that carbon nanoparticles can provide a means of self-sensing that enables the monitoring of moisture damage in GFRP. Despite the success of the proposed technique, it might not be able to efficiently describe moisture damage propagation in GFRP beyond a specific threshold because of the relatively high electrical conductivity of seawater. Microstructural investigations using Fourier Transform Infrared (FTIR explained the significance of seawater immersion time and temperature on the different levels of moisture damage in GFRP.

  11. Creep investigation of GFRP RC Beams - Part B: a theoretical framework

    Directory of Open Access Journals (Sweden)

    masmoudi abdelmonem

    2014-11-01

    Full Text Available This paper presents an analytical study about the viscoelastic time-dependent (creep behavior of pultruded GFRP elements made of polyester and E-glass fibres. Experimental results reported in Part A are firstly used for material characterization by means of empirical and phenomenological formulations.   The superposition principles by adopting the law of creep following the Eurocode 2 recommendations are also investigated. Analytical study was also conducted including creep under constant stress; successions of increasing stress superposition principle equivalent time and the return creep reloading. The results of this study revealed that Beams reinforced with GFRP are less marked with creep phenomenon.  This investigation should guide the civil engineer/designer for a better understanding creep phenomenon in GFRP reinforced concrete members.

  12. Performance and Characterization of Shear Ties for Use in Insulated Precast Concrete Sandwich Wall Panels

    Science.gov (United States)

    2010-11-01

    stainless 14 steel, galvanized carbon steel, carbon- fiber -reinforced polymer (CFRP), glass- fiber -reinforced polymer 15 (GFRP), and basalt - fiber ...CFRP Grid, (E) Universal Building Products GFRP Teplo Tie, and (F) Universal Building Products 6 Basalt FRP RockBar. Traditional steel connections...1.6 E Universal Building Products TeploTie GFRP Tie 10 mm dia. x 150 mm F RockBar Basalt FRP Bar 7 in. x 5/16 in. G TSA Manufacturing C-Clip

  13. Analysis of FRP bars used as reinforcement in concrete structures

    Directory of Open Access Journals (Sweden)

    Kinga Brózda

    2016-09-01

    Full Text Available In the design and construction of building and engineering structures, it is of utmost importance to provide their reliability and safety. The use of FRP (Fiber Reinforced Polymers bars as reinforcement of structural concrete elements could help reducing the typical defects of reinforced concrete and increase its strength parameters. In the paper the selected FRP bar characteristic properties are presented and advantages derived therefrom are specified. Furthermore, the most commonly used in construction types of FRP bars, depending on the raw material used during the production process are listed. In addition, the possibility of recycling of elements reinforced with FRP bars is presented and compared with traditional reinforced concrete (reinforced with steel bars. The production method of FRP bars (pultrusion is shown. Moreover, the advantages and disadvantages of using this method are discussed.

  14. The usage of carbon fiber reinforcement polymer and glass fiber reinforcement polymer for retrofit technology building

    Science.gov (United States)

    Tarigan, Johannes; Meka, Randi; Nursyamsi

    2018-03-01

    Fiber Reinforcement Polymer has been used as a material technology since the 1970s in Europe. Fiber Reinforcement Polymer can reinforce the structure externally, and used in many types of buildings like beams, columns, and slabs. It has high tensile strength. Fiber Reinforcement Polymer also has high rigidity and strength. The profile of Fiber Reinforcement Polymer is thin and light, installation is simple to conduct. One of Fiber Reinforcement Polymer material is Carbon Fiber Reinforcement Polymer and Glass Fiber Reinforcement Polymer. These materials is tested when it is installed on concrete cylinders, to obtain the comparison of compressive strength CFRP and GFRP. The dimension of concrete is diameter of 15 cm and height of 30 cm. It is amounted to 15 and divided into three groups. The test is performed until it collapsed to obtain maximum load. The results of research using CFRP and GFRP have shown the significant enhancement in compressive strength. CFRP can increase the compressive strength of 26.89%, and GFRP of 14.89%. For the comparison of two materials, CFRP is more strengthening than GFRP regarding increasing compressive strength. The usage of CFRP and GFRP can increase the loading capacity.

  15. FEM performance of concrete beams reinforced by carbon fiber bars

    Directory of Open Access Journals (Sweden)

    Hasan Hashim

    2018-01-01

    Full Text Available Concrete structures may be vulnerable to harsh environment, reinforcement with Fiber Reinforced Polymer (FRP bars have an increasing acceptance than normal steel. The nature of (FRP bar is (non-corrosive which is very beneficial for increased durability as well as the reinforcement of FRP bar has higher strength than steel bar. FRP usage are being specified more and more by public structural engineers and individual companies as main reinforcement and as strengthening of structures. Steel reinforcement as compared to (FRP reinforcement are decreasingly acceptable for structural concrete reinforcement including precast concrete, cast in place concrete, columns, beams and other components. Carbon Fiber Reinforcement Polymer (CFRP have a very high modulus of elasticity “high modulus” and very high tensile strength. In aerospace industry, CFRP with high modulus are popular among all FRPs because it has a high strength to weight ratio. In this research, a finite element models will be used to represent beams with Carbon Fiber Reinforcement and beams with steel reinforcement. The primary objective of the research is the evaluation of the effect of (CFR on beam reinforcement.

  16. Kapasitas Rekatan GFRP-S pada Balok Beton Akibat Perendaman Air Laut

    Directory of Open Access Journals (Sweden)

    Rudy Djamaluddin

    2015-04-01

    Full Text Available Glass Fiber Reinforced Polymer Sheet (GFRP-S is the non-corrosive material used for strengthening and has been widely used for many kinds of structures, such as buildings and structures exposed to marine environment. Its noncorrosive property is suitably purposed for the application of structures exposed to marine environment. Therefore, this study was conducted for analyzing the effect of sea water on bonding capacity of GFRP-S. Specimens were 12 concrete beams of 10 cm x 12 cm x 60 cm strengthened with GFRP-S. Three beams were not submersed in the sea while three beams were each submersed in the sea for 1 month, 3 months and 6 months, respectively. Testing was conducted on the ultimate load, the deflection, the GFRP-S strain and the concrete strain. From this study, it can be concluded that both the ultimate load and the bonding capacity of GFRP-S decreases along with the increasing of submersion period. The flexural capacity was decreased due to the decreasing of the bonding capacity of GFRP-S. The result of analysis indicates that the bonding capacity of GFRP-S decreased about 15% after submersed for 6 months in sea water.

  17. Study on Mechanical and Physical Behaviour of Hybrid GFRP

    Directory of Open Access Journals (Sweden)

    Nor Bahiyah Baba

    2015-01-01

    Full Text Available The paper discusses the mechanical and physical behaviour of hybrid glass fibre reinforced plastic (GFRP. Hybrid GFRP was fabricated by three different types of glass fibre, namely, 3D, woven, and chopped, which were selected and combined with mixture of polyester resin and hardener. The hybrid GFRP was investigated by varying three parameters which were the composite volume fractions, hybrid GFRP arrangement, and single type fibre. The hybrid GFRP was fabricated by using open mould hand lay-up technique. Mechanical testing was conducted by tensile test for strength and stiffness whereas physical testing was performed using water absorption and hardness. These tests were carried out to determine the effect of mechanical and physical behaviour over the hybrid GFRP. The highest volume fraction of 0.5 gives the highest strength and stiffness of 73 MPa and 821 MPa, respectively. Varying hybrid fibre arrangement which is the arrangement of chopped-woven-3D-woven-chopped showed the best value in strength of 66.2 MPa. The stiffness is best at arrangement of woven-chopped-woven-chopped-woven at 690 MPa. This arrangement also showed the lowest water absorption of 4.5%. Comparing the single fibre type, woven had overtaken the others in terms of both mechanical and physical properties.

  18. Estimation of durability of GFRP laminates under stress-corrosive environments using acoustic emission; AE wo mochiita ouryoku fushoku kankyoka deno GFRP no taikyusei hyoka

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Yoshimichi. [Seikow Chemical Engineering and Machinery, Ltd., Hyogo (Japan). Laboratory of Composite Materials; Nishiyabu, Kazuaki. [Osaka Prefectural College of Tehcnology, Osaka (Japan)

    1999-05-15

    The objective of this investigation is to estimate the creep life of glass fiber reinforced plastic (GFRP) under stress-corrosive environments using acoustic emission(AE). The laminates were fabricated using combinations of vinylester resin (R806) and random fiber mat or woven cloth. The creep tests were conducted in 5% nitric acid (HNO{sub 3}) environment. The AE depends on the loading level and the environment condition. For the creep test, the woven cloth reinforced specimens gave higher number of AE counts than the random mat reinforced specimens. The creep life decreased with increasing creep stress, whereas the rate of AE counts increased with increasing creep stress. A linear relationship was found between the creep life and the AE count rate. Using the proposed equation, a prediction of the creep life of GFRP under corrosive environments would presumably be possible. (author)

  19. Stress-strain relationship of high-strength steel (HSS) reinforcing bars

    Science.gov (United States)

    Anggraini, Retno; Tavio, Raka, I. Gede Putu; Agustiar

    2018-05-01

    The introduction of High-Strength Steel (HSS) reinforcing bars in reinforced concrete members has gained much attention in recent years and led to many advantages such as construction timesaving. It is also more economical since it can reduce the amount of reinforcing steel bars used in concrete members which in turn alleviates the congestion of reinforcement. Up to present, the building codes, e.g. American Concrete Institute (ACI) 318M-14 and Standard National Indonesia (SNI) 2847:2013, still restrict the use of higher-strength steel reinforcing bars for concrete design up to Grade 420 MPa due to the possible suspected brittle behavior of concrete members. This paper evaluates the characteristics of stress-strain relationships of HSS bars if they are comparable to the characteristics of those of Grade 420 MPa. To achieve the objective of the study, a series of steel bars from various grades (420, 550, 650, and 700 MPa) was selected. Tensile tests of these steel samples were conducted under displacement-controlled mode to capture the complete stress-strain curves and particularly the post-yield response of the steel bars. The results indicate that all the steel bars tested had the actual yield strengths greater than the corresponding specified values. The stress-strain curves of HSS reinforcing bars (Grade 550, 650, and 700 MPa) performed slightly different characteristics with those of Grade 420 MPa.

  20. Experimental Study on GFRP Surface Cracks Detection Using Truncated-Correlation Photothermal Coherence Tomography

    Science.gov (United States)

    Wang, Fei; Liu, Junyan; Mohummad, Oliullah; Wang, Yang

    2018-04-01

    In this paper, truncated-correlation photothermal coherence tomography (TC-PCT) was used as a nondestructive inspection technique to evaluate glass-fiber reinforced polymer (GFRP) composite surface cracks. Chirped-pulsed signal that combines linear frequency modulation and pulse excitation was proposed as an excitation signal to detect GFRP composite surface cracks. The basic principle of TC-PCT and extraction algorithm of the thermal wave signal feature was described. The comparison experiments between lock-in thermography, thermal wave radar imaging and chirped-pulsed photothermal radar for detecting GFRP artificial surface cracks were carried out. Experimental results illustrated that chirped-pulsed photothermal radar has the merits of high signal-to-noise ratio in detecting GFRP composite surface cracks. TC-PCT as a depth-resolved photothermal imaging modality was employed to enable three-dimensional visualization of GFRP composite surface cracks. The results showed that TC-PCT can effectively evaluate the cracks depth of GFRP composite.

  1. Machinability of glass fiber reinforced plastic (GFRP) composite ...

    African Journals Online (AJOL)

    This paper deals with the study of machinability of GFRP composite tubes of different fiber orientation angle vary from 300 to 900. Machining studies were carried out on an all geared lathe using three different cutting tools: namely Carbide (K-20), Cubic Boron Nitride (CBN) and Poly-Crystalline Diamond (PCD). Experiments ...

  2. Pengaruh Rendaman Air Laut terhadap Kapasitas Rekatan GFRP-Sheet pada Balok Beton Bertulang

    Directory of Open Access Journals (Sweden)

    Mufti Amir Sultan

    2017-04-01

    Full Text Available Construction of concrete structures that located in extreme environments are such as coastal areas will result in decreased strength or even the damage of the structures. As well know, chloride contained in sea water is responsible for strength reduction or structure failed were hence maintenance and repairs on concrete structure urgently needed. One popular method of structural improvements which under investigation is to use the material Glass Fiber Reinforced Polymer which has one of the advantages such as corrosion resistance. This research will be conducted experimental studies to investigate the flexural behavior of reinforced concrete beams with reinforcement GFRP-Sheet immersed in sea water using immersion time of 1, 3, 6 and 12 months. Test specimen consists of 11 pieces of reinforced beams with dimensions (15x20x330 cm that had been reinforced with GFRPSheet in the area of bending. The test specimen tested by providing a static load until it reaches the power limit, to record data during the test strain gauge mounted on the surface of the specimen and the GFRP-Sheet to collect the strain value. The result of analysis indicates the bonding capacity of GFRP Sheet decreases about 11.04% after immersed for 12 months in sea water.

  3. SEM in situ laboratory investigations on damage growth in GFRP composite under three-point bending tests

    DEFF Research Database (Denmark)

    Zhou, Hong Wei; Mishnaevsky, Leon; Brøndsted, Povl

    2010-01-01

    Glass fiber-reinforced polymer (GFRP) composites are widely used in low-weight constructions. SEM (scanning electron microscopy) in situ experiments of damage growth in GFRP composite under three-point bending loads are carried out. By summarizing the experimental results of three groups of samples...

  4. Extremely low temperature properties of epoxy GFRP

    International Nuclear Information System (INIS)

    Kadotani, Kenzo; Nagai, Matao; Aki, Fumitake.

    1983-01-01

    The examination of fiber-reinforced plastics, that is, plastics such as epoxy, polyester and polyimide reinforced with high strength fibers such as glass, carbon, boron and steel, for extremely low temperature use began from the fuel tanks of rockets. Therafter, the trial manufacture of superconducting generators and extremely low temperature transformers and the manufacture of superconducting magnets for nuclear fusion experimental setups became active, and high performance FRPs have been adopted, of which the extremely low temperature properties have been sufficiently grasped. Recently, the cryostats made of FRPs have been developed, fully utilizing such features of FRPs as high strength, high rigidity, non-magnetic material, insulation, low heat conductivity, light weight and the freedom of molding. In this paper, the mechanical properties at extremely low temperature of the plastic composite materials used as insulators and structural materials for extremely low temperature superconducting equipment is outlined, and in particular, glass fiber-reinforced epoxy laminates are described somewhat in detail. The fracture strain of GFRP at extremely low temperature is about 1.3 times as large as that at room temperature, but at extremely low temperature, clear cracking occurred at 40% of the fracture strain. The linear thermal contraction of GFRP showed remarkable anisotropy. (Kako, I.)

  5. Bonding capacity of the GFRP-S on strengthened RC beams after sea water immersion

    Science.gov (United States)

    Sultan, Mufti Amir; Djamaluddin, Rudy

    2017-11-01

    Construction of concrete structures that located in extreme environments are such as coastal areas will result in decreased strength or even the damage of the structures. As well know, chloride contained in sea water is responsible for strength reduction or structure fail were hence maintenance and repairs on concrete structure urgently needed. One popular method of structural improvements which under investigation is to use the material Glass Fibre Reinforced Polymer which has one of the advantages such as corrosion resistance. This research will be conducted experimental studies to investigate the bonding capacity behavior of reinforced concrete beams with reinforcement GFRP-S immersed in sea water using immersion time of one month, three months, six months and twelve months. Test specimen consists of 12 pieces of reinforced concrete beams with dimensions (150x200x3000) mm that had been reinforced with GFRP-S in the area of bending, the beam without immersion (B0), immersion one month (B1), three months (B3), six months (B6) and twelve months (B12). Test specimen were cured for 28 days before the application of the GFRP sheet. Test specimen B1, B3, B6 and B12 that have been immersed in sea water pool with a immersion time each 1, 3, 6 and 12 months. The test specimen without immersion test by providing a static load until it reaches the failure, to record data during the test strain gauge mounted on the surface of the specimen and the GFRP to collect the strain value. From the research it obvious that there is a decrease bonding capacity on specimens immersed for one month, three months, six months and twelve months against the test object without immersion of 8.85%; 8.89%; 9.33% and 11.04%.

  6. Glass FRP reinforcement in rehabilitation of concrete marine infrastructure

    International Nuclear Information System (INIS)

    Newhook, John P.

    2006-01-01

    Fiber reinforced polymer (FRP) reinforcements for concrete structures are gaining wide acceptance as a suitable alternative to steel reinforcements. The primary advantage is that they do not suffer corrosion and hence they promise to be more durable in environments where steel reinforced concrete has a limited life span. Concrete wharves and jetties are examples of structures subjected to such harsh environments and represent the general class of marine infrastructure in which glass FRP (GFRP) reinforcement should be used for improved durability and service life. General design considerations which make glass FRP suitable for use in marine concrete rehabilitation projects are discussed. A case study of recent wharf rehabilitation project in Canada is used to reinforce these considerations. The structure consisted of a GFRP reinforced concrete deck panel and steel - GFRP hybrid reinforced concrete pile cap. A design methodology is developed for the hybrid reinforcement design and verified through testing. The results of a field monitoring program are used to establish the satisfactory field performance of the GFRP reinforcement. The design concepts presented in the paper are applicable to many concrete marine components and other structures where steel reinforcement corrosion is a problem. (author)

  7. Bond of reinforcing bars in self-compacting steel fiber reinforced concrete

    NARCIS (Netherlands)

    Schumacher, P.; Bigaj-van Vliet, A.J.; Braam, C.R.; Uijl, J.A. den; Walraven, J.C.

    2002-01-01

    Pull-out tests were performed on 10 mm diameter ribbed bars embedded along three times the bar diameter in 200 mm cubes made of plain and steel fiber reinforced concrete (SFRC) of normal strength (B45). The fiber content was 60 and 120 kg/m3, respectively, the aspect ratio of the fibers was 45 and

  8. A Study on Load Carrying Capacity of Fly Ash Based Polymer Concrete Columns Strengthened Using Double Layer GFRP Wrapping

    Directory of Open Access Journals (Sweden)

    S. Nagan

    2014-01-01

    Full Text Available This paper investigates the suitability of glass fiber reinforced polymer (GFRP sheets in strengthening of fly ash based polymer members under compression. Experimental results revealed that load carrying capacity of the confined columns increases with GFRP sheets wrapping. Altogether 18 specimens of M30 and G30 grade short columns were fabricated. The G30 specimens were prepared separately in 8 molarity and 12 molarity of sodium hydroxide concentration. Twelve specimens for low calcium fly ash based reinforced polymer concrete and six specimens of ordinary Portland cement reinforced concrete were cast. Three specimens from each molarity fly ash based reinforced polymer concrete and ordinary Portland cement reinforced concrete were wrapped with double layer of GFRP sheets. The load carrying capacity of fly ash based polymer concrete was tested and compared with control specimens. The results show increase in load carrying capacity and ductility index for all strengthened elements. The maximum increase in load carrying capacity was 68.53% and is observed in strengthened G30 specimens.

  9. Extruded bar reinforced structure and manufacturing procedures

    International Nuclear Information System (INIS)

    Truchet, J.M.; Bozetto, P.

    1989-01-01

    A cooling tower has horizontal hoops connected by two inclined sets of bars to form a trellis of equilateral triangle anchored in the ground. The bars and hoops are connected at the corners of the triangle. A skin stretched over the trellis defines the tower. The bars are made with thermosetting resin reinforced by fibres. The fabrication of such tower is cheep and simple it can be used for every type of electrical power station, nuclear or not [fr

  10. Prediction of crack due to corrosion of reinforcing bar in low alkali concrete

    International Nuclear Information System (INIS)

    Takeda, Nobufumi; Iriya, Keishiro; Hitomi, Takashi; Konishi, Kazuhiro; Kurihara, Yuji

    2008-01-01

    Steel-reinforced low alkaline concrete containing pozzolan has been examined for application in high level radioactive waste disposal. Marine exposure examinations a period of six years were performed for concrete with 30% water-cement ratio, and the reduction in its compressive strength, the intrusion depth of chloride ions, and the corrosion of the reinforcing bar were investigated. On the basis of these results, the progress of corrosion of the reinforcing bar and the outbreak time of a corrosion crack in the reinforcing bar were predicted. The following results are obtained. 1) There was no decrease in the compressive strength of the test pieces during the marine exposure examinations. 2) There was little penetration of the chloride ions in comparison with ordinary Portland cement. 3) Although the corrosion of the reinforcing bar commenced at an early stage with a little quantity of chloride ion intrusion, the progress over the period of six years was extremely small. 4) The corrosion rate of the reinforcing bar in groundwater including sea water was estimated as 0.30-0.55 mg/(cm 2 ·year). In the case of a reinforcing bar with a thickness of 100 mm and diameter of 22 mm, the outbreak time of the reinforcing corrosion crack was predicted as 50-100 years after construction. (author)

  11. Effect of the reinforcement bar arrangement on the efficiency of electrochemical chloride removal technique applied to reinforced concrete structures

    International Nuclear Information System (INIS)

    Garces, P.; Sanchez de Rojas, M.J.; Climent, M.A.

    2006-01-01

    This paper reports on the research done to find out the effect that different bar arrangements may have on the efficiency of the electrochemical chloride removal (ECR) technique when applied to a reinforced concrete structural member. Five different types of bar arrangements were considered, corresponding to typical structural members such as columns (with single and double bar reinforcing), slabs, beams and footings. ECR was applied in several steps. We observe that the extraction efficiency depends on the reinforcing bar arrangement. A uniform layer set-up favours chloride extraction. Electrochemical techniques were also used to estimate the reinforcing bar corrosion states, as well as measure the corrosion potential, and instant corrosion rate based on the polarization resistance technique. After ECR treatment, a reduction in the corrosion levels is observed falling short of the depassivation threshold

  12. Numerical Simulation of Thermal Performance of Glass-Fibre-Reinforced Polymer

    Science.gov (United States)

    Zhao, Yuchao; Jiang, Xu; Zhang, Qilin; Wang, Qi

    2017-10-01

    Glass-Fibre-Reinforced Polymer (GFRP), as a developing construction material, has a rapidly increasing application in civil engineering especially bridge engineering area these years, mainly used as decorating materials and reinforcing bars for now. Compared with traditional construction material, these kinds of composite material have obvious advantages such as high strength, low density, resistance to corrosion and ease of processing. There are different processing methods to form members, such as pultrusion and resin transfer moulding (RTM) methods, which process into desired shape directly through raw material; meanwhile, GFRP, as a polymer composite, possesses several particular physical and mechanical properties, and the thermal property is one of them. The matrix material, polymer, performs special after heated and endue these composite material a potential hot processing property, but also a poor fire resistance. This paper focuses on thermal performance of GFRP as panels and corresponding researches are conducted. First, dynamic thermomechanical analysis (DMA) experiment is conducted to obtain the glass transition temperature (Tg) of the object GFRP, and the curve of bending elastic modulus with temperature is calculated according to the experimental data. Then compute and estimate the values of other various thermal parameters through DMA experiment and other literatures, and conduct numerical simulation under two condition respectively: (1) the heat transfer process of GFRP panel in which the panel would be heated directly on the surface above Tg, and the hot processing under this temperature field; (2) physical and mechanical performance of GFRP panel under fire condition. Condition (1) is mainly used to guide the development of high temperature processing equipment, and condition (2) indicates that GFRP’s performance under fire is unsatisfactory, measures must be taken when being adopted. Since composite materials’ properties differ from each other

  13. Stripping demolition of concrete by applying electric current through reinforcing bars

    International Nuclear Information System (INIS)

    Nakagawa, Wahei; Kumegawa, Sadatsune

    1995-01-01

    The presence of reinforcing bars in reinforced concrete structures is an obstruction hindering the smooth progress of demolition works. The electric heating method is, on the other hand, a demolition technique of unique concept since it adopts the bars to help the demolition of reinforced concrete structures. This technique has the following advantages for demolition: 1) the more densely a structure is reinforced with bars, the greater is the effect of the electric heating, 2) demolition after heating produces little dust, and 3) electric heating of reinforcing bars causes no damage to the portions of concrete not subjected to electric current. The present paper describes the procedures and results of a series of experiments we conducted to verify the efficiency of the electric heating method. In this method, a low-voltage high-current is run through reinforcing bars existing in a concrete structure, inducing intense heat in the bars which in its turn brings about cracks in the surrounding concrete mass, facilitating secondary demolition by hammer picks or other means. The experiments were performed on full-scale biological shield wall mock-ups of a BWR and a small nuclear reactor. The experiments revealed that these excellent features of the electric heating method are worth utilizing in stripping demolition of radioactivated regions of biological shield walls in nuclear power plants. The electric heating method is currently being adopted and shows effective results in partial demolition works in diaphragm wall shafts where starting/arriving holes are to be fixed for shield machines without damaging surrounding portions. (author)

  14. Optimizing the Flexural Strength of Beams Reinforced with Fiber Reinforced Polymer Bars Using Back-Propagation Neural Networks

    Directory of Open Access Journals (Sweden)

    Bahman O. Taha

    2015-06-01

    Full Text Available The reinforced concrete with fiber reinforced polymer (FRP bars (carbon, aramid, basalt and glass is used in places where a high ratio of strength to weight is required and corrosion is not acceptable. Behavior of structural members using (FRP bars is hard to be modeled using traditional methods because of the high non-linearity relationship among factors influencing the strength of structural members. Back-propagation neural network is a very effective method for modeling such complicated relationships. In this paper, back-propagation neural network is used for modeling the flexural behavior of beams reinforced with (FRP bars. 101 samples of beams reinforced with fiber bars were collected from literatures. Five important factors are taken in consideration for predicting the strength of beams. Two models of Multilayer Perceptron (MLP are created, first with single-hidden layer and the second with two-hidden layers. The two-hidden layer model showed better accuracy ratio than the single-hidden layer model. Parametric study has been done for two-hidden layer model only. Equations are derived to be used instead of the model and the importance of input factors is determined. Results showed that the neural network is successful in modeling the behavior of concrete beams reinforced with different types of (FRP bars.

  15. Nonlinear analysis of the GFRP material wheel hub

    Directory of Open Access Journals (Sweden)

    Dong Yun-Feng

    2015-01-01

    Full Text Available In this paper, the current bicycle wheel was replaced by the ones which composed by the wheel hub with Glassfiber Reinforced Plastic (alkali free thin-walled cylinder material, hereinafter referred to as GFRP material and the protective components made up of rubber outer pneumatic pad. With the help of the basic theory of elastic-plastic mechanics, the finite element “Nonlinear buckling” analysis of the wheel was carried out. The results show that the maximum elastic deformation of the wheel hub and the critical value of buckling failure load were restricted by the elasticity under the condition of external loads. Considering with the tensile strength and elastic modulus of the GFRP value of the material, it is demonstrated that the material is feasible to be used for wheel hub.

  16. Fracture detection in concrete by glass fiber cloth reinforced plastics

    Science.gov (United States)

    Shin, Soon-Gi; Lee, Sung-Riong

    2006-04-01

    Two types of carbon (carbon fiber and carbon powder) and a glass cloth were used as conductive phases and a reinforcing fiber, respectively, in polymer rods. The carbon powder was used for fabricating electrically conductive carbon powder-glass fiber reinforced plastic (CP-GFRP) rods. The carbon fiber tows and the CP-GFRP rods were adhered to mortar specimens using epoxy resin and glass fiber cloth. On bending, the electrical resistance of the carbon fiber tow attached to the mortar specimen increased greatly after crack generation, and that of the CP-GFRP rod increased after the early stages of deflection in the mortar. Therefore, the CP-GFRP rod is superior to the carbon fiber tow in detecting fractures. Also, by reinforcing with a glass fiber cloth reinforced plastic, the strength of the mortar specimens became more than twice as strong as that of the unreinforced mortar.

  17. 77 FR 64127 - Steel Concrete Reinforcing Bar From Belarus, China, Indonesia, Latvia, Moldova, Poland, and...

    Science.gov (United States)

    2012-10-18

    ...)] Steel Concrete Reinforcing Bar From Belarus, China, Indonesia, Latvia, Moldova, Poland, and Ukraine... determine whether revocation of the antidumping duty orders on steel concrete reinforcing bar from Belarus... concrete reinforcing bar from Latvia and Moldova. The Commission found that the respondent interested party...

  18. 77 FR 39254 - Steel Concrete Reinforcing Bar From Belarus, China, Indonesia, Latvia, Moldova, Poland, and...

    Science.gov (United States)

    2012-07-02

    ...)] Steel Concrete Reinforcing Bar From Belarus, China, Indonesia, Latvia, Moldova, Poland, and Ukraine; Institution of Five-Year Reviews Concerning the Antidumping Duty Orders on Steel Concrete Reinforcing Bar From... revocation of the antidumping duty orders on steel concrete reinforcing bar from Belarus, China, Indonesia...

  19. 77 FR 71631 - Steel Concrete Reinforcing Bar From Belarus, China, Indonesia, Latvia, Moldova, Poland, and...

    Science.gov (United States)

    2012-12-03

    ...)] Steel Concrete Reinforcing Bar From Belarus, China, Indonesia, Latvia, Moldova, Poland, and Ukraine; Scheduling of Full Five-Year Reviews Concerning the Antidumping Duty Orders on Steel Concrete Reinforcing Bar...) to determine whether revocation of the antidumping duty orders on steel concrete reinforcing bar from...

  20. Fiberglass Grids as Sustainable Reinforcement of Historic Masonry

    Science.gov (United States)

    Righetti, Luca; Edmondson, Vikki; Corradi, Marco; Borri, Antonio

    2016-01-01

    Fiber-reinforced composite (FRP) materials have gained an increasing success, mostly for strengthening, retrofitting and repair of existing historic masonry structures and may cause a significant enhancement of the mechanical properties of the reinforced members. This article summarizes the results of previous experimental activities aimed at investigating the effectiveness of GFRP (Glass Fiber Reinforced Polymers) grids embedded into an inorganic mortar to reinforce historic masonry. The paper also presents innovative results on the relationship between the durability and the governing material properties of GFRP grids. Measurements of the tensile strength were made using specimens cut off from GFRP grids before and after ageing in aqueous solution. The tensile strength of a commercially available GFRP grid has been tested after up 450 days of storage in deionized water and NaCl solution. A degradation in tensile strength and Young’s modulus up to 30.2% and 13.2% was recorded, respectively. This degradation indicated that extended storage in a wet environment may cause a decrease in the mechanical properties. PMID:28773725

  1. 78 FR 43858 - Steel Concrete Reinforcing Bars From Belarus, Indonesia, Latvia, Moldova, Poland, the People's...

    Science.gov (United States)

    2013-07-22

    ...-860; A-822-804; A-823-809; A- 841-804] Steel Concrete Reinforcing Bars From Belarus, Indonesia, Latvia... antidumping duty orders \\1\\ on steel concrete reinforcing bars from Belarus, Indonesia, Latvia, Moldova... orders. \\1\\ See Antidumping Duty Orders: Steel Concrete Reinforcing Bars From Belarus, Indonesia, Latvia...

  2. Tensile Capacity of U-bar Loop Connections with Precast Fiber Reinforced Dowels

    DEFF Research Database (Denmark)

    Sørensen, Jesper Harrild; Hoang, Linh Cao; Olesen, John Forbes

    2016-01-01

    This paper describes an investigation of the tensile capacity of in-situ cast U-bar loop connections between precast concrete elements. The basic idea is to introduce a small precast cylindrical dowel of fiber reinforced mortar that fits into the bend diameter of the overlapping U...... that use of a precast fiber reinforced dowel performs at a slightly lower load level, as compared to a connection grouted solely with regular mortar and reinforced with the same amount of transverse reinforcement. However, the load-displacement response of specimens with a fiber reinforced dowel is closer......-bars. The remaining part of the connection is cast in-situ with a regular mortar, which then encapsulates the precast dowel. Different dowel configurations have been investigated, including the use of steel or synthetic fibers with or without lacer bars placed within the precast dowel. The experimental results show...

  3. 78 FR 60831 - Steel Concrete Reinforcing Bar From Turkey: Initiation of Countervailing Duty Investigation

    Science.gov (United States)

    2013-10-02

    ... DEPARTMENT OF COMMERCE International Trade Administration [C-489-819] Steel Concrete Reinforcing... concrete reinforcing bar (``rebar'') from the Republic of Turkey (``Turkey''), filed in proper form on... of Steel Concrete Reinforcing Bar from the Republic of Turkey, dated September 4, 2013. \\2...

  4. Modelling Dowel Action of Discrete Reinforcing Bars in Cracked Concrete Structures

    International Nuclear Information System (INIS)

    Kwan, A. K. H.; Ng, P. L.; Lam, J. Y. K.

    2010-01-01

    Dowel action is one of the component actions for shear force transfer in cracked reinforced concrete. In finite element analysis of concrete structures, the use of discrete representation of reinforcing bars is considered advantageous over the smeared representation due to the relative ease of modelling the bond-slip behaviour. However, there is very limited research on how to simulate the dowel action of discrete reinforcing bars. Herein, a numerical model for dowel action of discrete reinforcing bars crossing cracks in concrete is developed. The model features the derivation of dowel stiffness matrix based on beam-on-elastic-foundation theory and the direct assemblage of dowel stiffness into the concrete element stiffness matrices. The dowel action model is incorporated in a nonlinear finite element programme with secant stiffness formulation. Deep beams tested in the literature are analysed and it is found that the incorporation of dowel action model improves the accuracy of analysis.

  5. 78 FR 41079 - Steel Concrete Reinforcing Bar From Belarus, China, Indonesia, Latvia, Moldova, Poland, and Ukraine

    Science.gov (United States)

    2013-07-09

    ...)] Steel Concrete Reinforcing Bar From Belarus, China, Indonesia, Latvia, Moldova, Poland, and Ukraine... U.S.C. 1675(c)), that revocation of the antidumping duty orders on steel concrete reinforcing bar... Commission are contained in USITC Publication 4409 (July 2013), entitled Steel Concrete Reinforcing Bar from...

  6. Composite GFRP U-Shaped Footbridge

    Directory of Open Access Journals (Sweden)

    Chróścielewski Jacek

    2017-04-01

    Full Text Available The paper presents proposals for the use of glass fiber reinforced polymer composites for the construction of engineering objects, known and commonly used in the shipbuilding industry. An example of a pedestrian footbridge was used in this case, which, despite the considerable thickness of the structural material, was made using infusion technology in one production cycle. The designed and produced footbridge span is durable, dynamically resistant, incombustible, easy to install and maintain, resistant to weather conditions and also aesthetically interesting. For footbridge production environmentally friendly PET foam core may be used. It may come from recycling of used plastic packages and which is produced with less energy consumption process and much less CO2 emission. The load bearing part of the structure (skin is made of polymer laminate reinforced with glass fabrics (GFRP.

  7. Moment-Curvature Behaviors of Concrete Beams Singly Reinforced by Steel-FRP Composite Bars

    Directory of Open Access Journals (Sweden)

    Zeyang Sun

    2017-01-01

    Full Text Available A steel-fiber-reinforced polymer (FRP composite bar (SFCB is a kind of rebar with inner steel bar wrapped by FRP, which can achieve a better anticorrosion performance than that of ordinary steel bar. The high ultimate strength of FRP can also provide a significant increase in load bearing capacity. Based on the adequate simulation of the load-displacement behaviors of concrete beams reinforced by SFCBs, a parametric analysis of the moment-curvature behaviors of concrete beams that are singly reinforced by SFCB was conducted. The critical reinforcement ratio for differentiating the beam’s failure mode was presented, and the concept of the maximum possible peak curvature (MPPC was proposed. After the ultimate curvature reached MPPC, it decreased with an increase in the postyield stiffness ratio (rsf, and the theoretical calculation method about the curvatures before and after the MPPC was derived. The influence of the reinforcement ratio, effective depth, and FRP ultimate strain on the ultimate point was studied by the dimensionless moment and curvature. By calculating the envelope area under the moment-curvature curve, the energy ductility index can obtain a balance between the bearing capacity and the deformation ability. This paper can provide a reference for the design of concrete beams that are reinforced by SFCB or hybrid steel bar/FRP bar.

  8. Prediction of punching shear capacities of two-way concrete slabs reinforced with FRP bars

    Directory of Open Access Journals (Sweden)

    Ibrahim M. Metwally

    2013-08-01

    Full Text Available Where corrosion of steel reinforcement is a concern, fiber-reinforced polymer (FRP reinforcing bar or grid reinforcement provides an alternative reinforcement for concrete flat slabs. The existing provisions for punching of slabs in most international design standards for reinforced concrete are based on tests of steel reinforced slabs. The elastic stiffness and bonding characteristics of FRP reinforcement are sufficiently different from those of steel to affect punching strength [1]. This paper evaluates the punching shear strength of concrete flat slabs reinforced with different types of fiber-reinforced polymer (FRP. A total of 59 full-size slabs were constructed and tested collected from the literature of FRP bars reinforced concrete slabs. The test parameters were the amount of FRP reinforcing bars, Young’s modulus of FRP bars, slab thickness, loaded areas and concrete compressive strength. The experimental punching shear strengths were compared with the available theoretical predictions, including the ACI 318 Code, BS 8110 Code, ACI 440 design guidelines, and a number of models proposed by some researchers in the literature. Two approaches for predicting the punching strength of FRP-reinforced slabs are examined. The first is an empirical new model which is considered as a modification of El-Gamal et al. [2] model. The second is a Neural Networks Technique; which has been developed to predict the punching shear capacity of FRP reinforced concrete slabs. The accuracies of both methods were evaluated against the experimental test data. They attained excellent agreement with available test results compared to the existing design formulas.

  9. STRUCTURE AND MECHANICAL PROPERTIES’ RESEARCH OF A500C-CLASS REINFORCEMENT BARS

    Directory of Open Access Journals (Sweden)

    A. M. Yaznevich

    2010-01-01

    Full Text Available Structural and mechanical properties of A500C-class reinforcement bars are investigated in the paper. The paper demonstrates that rolled products of thermally strengthened reinforcement have a layered structure with coaxially located layers having different mechanical characteristics. Micro-hardness measurements have shown that the maximum hardness has a pre-surface part of a reinforcement bar, and the minimum hardness is in the central part. Thickness of the strengthened surface layers grows while increasing a diameter and at preservation of structural composition. 

  10. Corrosion of reinforcement bars in steel ibre reinforced concrete structures

    DEFF Research Database (Denmark)

    Solgaard, Anders Ole Stubbe

    and the influence of steel fibres on initiation and propagation of cracks in concrete. Moreover, the impact of fibres on corrosion-induced cover cracking was covered. The impact of steel fibres on propagation of reinforcement corrosion was investigated through studies of their impact on the electrical resistivity...... of concrete, which is known to affect the corrosion process of embedded reinforcement. The work concerning the impact of steel fibres on initiation and propagation of cracks was linked to corrosion initiation and propagation of embedded reinforcement bars via additional studies. Cracks in the concrete cover...... are known to alter the ingress rate of depassivating substances and thereby influence the corrosion process. The Ph.D. study covered numerical as well as experimental studies. Electrochemically passive steel fibres are electrically isolating thus not changing the electrical resistivity of concrete, whereas...

  11. Structural design guidelines for concrete bridge decks reinforced with corrosion-resistant reinforcing bars.

    Science.gov (United States)

    2014-10-01

    This research program develops and validates structural design guidelines and details for concrete bridge decks with : corrosion-resistant reinforcing (CRR) bars. A two-phase experimental program was conducted where a control test set consistent : wi...

  12. 77 FR 70140 - Steel Concrete Reinforcing Bars From Belarus, Indonesia, Latvia, Moldova, Poland, People's...

    Science.gov (United States)

    2012-11-23

    ...-860; A-822-804; A-823-809; A- 841-804] Steel Concrete Reinforcing Bars From Belarus, Indonesia, Latvia... concrete reinforcing bars from Belarus, Indonesia, Latvia, Moldova, Poland, the People's Republic of China...-0371, respectively. SUPPLEMENTARY INFORMATION: Background The antidumping duty orders on steel concrete...

  13. Effect of Different Fillers on Adhesive Wear Properties of Glass Fiber Reinforced Polyester Composites

    Directory of Open Access Journals (Sweden)

    E. Feyzullahoğlu

    2017-12-01

    Full Text Available Polymeric composites are used for different aims as substitute of traditional materials such as metals; due to their improved strength at small specific weight. The fiber reinforced polymer (FRP composite material consists of polymeric matrix and reinforcing material. Polymeric materials are commonly reinforced with synthetic fibers such as glass and carbon. The glass fiber reinforced polyester (GFRP composites are used with different filler materials. The aim of this study is to investigate the effects of different filler materials on adhesive wear behavior of GFRP. In this experimental study; polymetilmetacrilat (PMMA, Glass beads (GB and Glass sand (GS were used as filling material in GFRP composite samples. The adhesive wear behaviors of samples were carried out using ball on disc type tribometer. The friction force and coefficient of friction were measured during the test. The volume loss and wear rate values of samples were calculated according to test results. Barcol hardness values of samples were measured. The densities of samples were measured. Results show that the wear resistance of GB filled GFRP composite samples was much more than non-filled and PMMA filled GFRP composite samples.

  14. Mechanical interaction of Engineered Cementitious Composite (ECC) reinforced with Fiber Reinforced Polymer (FRP) rebar in tensile loading

    DEFF Research Database (Denmark)

    Lárusson, Lárus Helgi; Fischer, Gregor; Jönsson, Jeppe

    2010-01-01

    This paper introduces a preliminary study of the composite interaction of Engineered Cementitious Composite (ECC), reinforced with Glass Fiber Reinforced Polymer (GFRP) rebar. The main topic of this paper will focus on the interaction of the two materials (ECC and GFRP) during axial loading......, particularly in post cracking phase of the concrete matrix. The experimental program carried out in this study examined composite behavior under monotonic and cyclic loading of the specimens in the elastic and inelastic deformation phases. The stiffness development of the composite during loading was evaluated...

  15. An Experimental Study on Strengthening of Reinforced Concrete Flexural Members using Steel Wire Mesh

    Directory of Open Access Journals (Sweden)

    Al Saadi Hamza Salim Mohammed

    2017-01-01

    Full Text Available One of the major challenges and contemporary research in the field of structural engineering is strengthening of existing structural elements using readily available materials in the market. Several investigations were conducted on strengthening of various structural components using traditional and advanced materials. Many researchers tried to enhance the reinforced concrete (RC beams strength using steel plate, Glass and Carbon Fibre Reinforced Polymers (GFRP & CFRP. For the reason that high weight to the strength ratio and compatibility in strength between FRP composites and steel bars, steel plates and GFRP and CFRP composites are not used for strengthening works practically. Hence, in this present work the suitability of using wire mesh for the purpose of strengthening the RC flexural members is studied by conducting experimental works. New technique of strengthening system using wire mesh with a view to improve sectional properties and subsequently flexural strength of RC beams is adopted in this work. The results for experimental and theoretical analysis were compared and found that good correlation exists between them. The experimental results indicate that RC beams strengthened with steel wire mesh are easy technique for strengthening of existing flexural members.

  16. Monitoring Corrosion of Steel Bars in Reinforced Concrete Structures

    Science.gov (United States)

    Verma, Sanjeev Kumar; Bhadauria, Sudhir Singh; Akhtar, Saleem

    2014-01-01

    Corrosion of steel bars embedded in reinforced concrete (RC) structures reduces the service life and durability of structures causing early failure of structure, which costs significantly for inspection and maintenance of deteriorating structures. Hence, monitoring of reinforcement corrosion is of significant importance for preventing premature failure of structures. This paper attempts to present the importance of monitoring reinforcement corrosion and describes the different methods for evaluating the corrosion state of RC structures, especially hal-cell potential (HCP) method. This paper also presents few techniques to protect concrete from corrosion. PMID:24558346

  17. Monitoring corrosion of steel bars in reinforced concrete structures.

    Science.gov (United States)

    Verma, Sanjeev Kumar; Bhadauria, Sudhir Singh; Akhtar, Saleem

    2014-01-01

    Corrosion of steel bars embedded in reinforced concrete (RC) structures reduces the service life and durability of structures causing early failure of structure, which costs significantly for inspection and maintenance of deteriorating structures. Hence, monitoring of reinforcement corrosion is of significant importance for preventing premature failure of structures. This paper attempts to present the importance of monitoring reinforcement corrosion and describes the different methods for evaluating the corrosion state of RC structures, especially hal-cell potential (HCP) method. This paper also presents few techniques to protect concrete from corrosion.

  18. Monitoring Corrosion of Steel Bars in Reinforced Concrete Structures

    Directory of Open Access Journals (Sweden)

    Sanjeev Kumar Verma

    2014-01-01

    Full Text Available Corrosion of steel bars embedded in reinforced concrete (RC structures reduces the service life and durability of structures causing early failure of structure, which costs significantly for inspection and maintenance of deteriorating structures. Hence, monitoring of reinforcement corrosion is of significant importance for preventing premature failure of structures. This paper attempts to present the importance of monitoring reinforcement corrosion and describes the different methods for evaluating the corrosion state of RC structures, especially hal-cell potential (HCP method. This paper also presents few techniques to protect concrete from corrosion.

  19. Mechanical properties and production quality of hand-layup and vacuum infusion processed hybrid composite materials for GFRP marine structures

    Science.gov (United States)

    Kim, Sang-Young; Shim, Chun Sik; Sturtevant, Caleb; Kim, Dave (Dae-Wook); Song, Ha Cheol

    2014-09-01

    Glass Fiber Reinforced Plastic (GFRP) structures are primarily manufactured using hand lay-up or vacuum infusion techniques, which are cost-effective for the construction of marine vessels. This paper aims to investigate the mechanical properties and failure mechanisms of the hybrid GFRP composites, formed by applying the hand lay-up processed exterior and the vacuum infusion processed interior layups, providing benefits for structural performance and ease of manufacturing. The hybrid GFRP composites contain one, two, and three vacuum infusion processed layer sets with consistent sets of hand lay-up processed layers. Mechanical properties assessed in this study include tensile, compressive and in-plane shear properties. Hybrid composites with three sets of vacuum infusion layers showed the highest tensile mechanical properties while those with two sets had the highest mechanical properties in compression. The batch homogeneity, for the GFRP fabrication processes, is evaluated using the experimentally obtained mechanical properties

  20. Mechanical properties and production quality of hand-layup and vacuum infusion processed hybrid composite materials for GFRP marine structures

    Directory of Open Access Journals (Sweden)

    Kim Sang-Young

    2014-09-01

    Full Text Available Glass Fiber Reinforced Plastic (GFRP structures are primarily manufactured using hand lay-up or vacuum infusion techniques, which are cost-effective for the construction of marine vessels. This paper aims to investigate the mechanical properties and failure mechanisms of the hybrid GFRP composites, formed by applying the hand lay-up processed exterior and the vacuum infusion processed interior layups, providing benefits for structural performance and ease of manufacturing. The hybrid GFRP composites contain one, two, and three vacuum infusion processed layer sets with consistent sets of hand lay-up processed layers. Mechanical properties assessed in this study include tensile, compressive and in-plane shear properties. Hybrid composites with three sets of vacuum infusion layers showed the highest tensile mechanical properties while those with two sets had the highest mechanical properties in compression. The batch homogeneity, for the GFRP fabrication processes, is evaluated using the experimentally obtained mechanical properties

  1. Mechanical properties and production quality of hand-layup and vacuum infusion processed hybrid composite materials for GFRP marine structures

    Directory of Open Access Journals (Sweden)

    Sang-Young Kim

    2014-09-01

    Full Text Available Glass Fiber Reinforced Plastic (GFRP structures are primarily manufactured using hand lay-up or vacuum infusion techniques, which are cost-effective for the construction of marine vessels. This paper aims to investigate the mechanical properties and failure mechanisms of the hybrid GFRP composites, formed by applying the hand lay-up processed exterior and the vacuum infusion processed interior layups, providing benefits for structural performance and ease of manufacturing. The hybrid GFRP composites contain one, two, and three vacuum infusion processed layer sets with consistent sets of hand lay-up processed layers. Mechanical properties assessed in this study include tensile, compressive and in-plane shear properties. Hybrid composites with three sets of vacuum infusion layers showed the highest tensile mechanical properties while those with two sets had the highest mechanical properties in compression. The batch homogeneity, for the GFRP fabrication processes, is evaluated using the experimentally obtained mechanical properties.

  2. Deflection of Steel Reinforced Concrete Beam Prestressed With CFRP Bar

    Directory of Open Access Journals (Sweden)

    Selvachandran P.

    2017-09-01

    Full Text Available Carbon Fiber Reinforced polymer (CFRP bars are weak in yielding property which results in sudden failure of structure at failure load. Inclusion of non-pretensioned steel reinforcement in the tension side of CFRP based prestressed concrete beam will balance the yielding requirements of member and it will show the definite crack failure pattern before failure. Experimental investigation has been carried out to study the deflection behavior of partially prestressed beam. Experimental works includes four beam specimens stressed by varying degree of prestressing. The Partial Prestressing Ratio (PPR of specimen is considered for experimental works in the range of 0.6 to 0.8. A new deflection model is recommended in the present study considering the strain contribution of CFRP bar and steel reinforcement for the fully bonded member. New deflection model converges to experimental results with the error of less than 5% .

  3. A study of the blade's material performance made of GFRP for 100kW tidal current turbine

    International Nuclear Information System (INIS)

    Kim, Jung Min; Chung, Hyun; Kim, Jong Sung

    2009-01-01

    The aim of this study is to investigate the performance of material of rotary blade which was designed for a energy system which utilizes a tide, a comparatively stable and predictable energy source. The rotary blade design for Horizontal Axis Tidal Turbine was carried out to convert an energy. And, considering seawater corrosion and material weight, Glass Fiber Reinforced Polymer (GFRP) was applied as the material of rotary blade. GFRP is a light material comparing with metal materials, while it has a sufficient stiffness, and GFRP has durability against seawater corrosion. However, it is suggested that the performance verification of material, since the material was built based on a polymer. And the performance verification of material was carried out comparing the results from experimental test and the results from finite element analysis using Nastran FX.

  4. 78 FR 55755 - Steel Concrete Reinforcing Bar From Mexico and Turkey; Institution of Antidumping and...

    Science.gov (United States)

    2013-09-11

    ... INTERNATIONAL TRADE COMMISSION [Investigation Nos. 701-TA-502 and 731-TA-1227-1228 (Preliminary)] Steel Concrete Reinforcing Bar From Mexico and Turkey; Institution of Antidumping and Countervailing... of imports from Mexico and Turkey of steel concrete reinforcing bar, primarily provided for in...

  5. Incremental dynamic analysis of concrete moment resisting frames reinforced with shape memory composite bars

    International Nuclear Information System (INIS)

    Zafar, Adeel; Andrawes, Bassem

    2012-01-01

    Fiber reinforced polymer (FRP) reinforcing bars have been used in concrete structures as an alternative to conventional steel reinforcement, in order to overcome corrosion problems. However, due to the linear behavior of the commonly used reinforcing fibers, they are not considered in structures which require ductility and damping characteristics. The use of superelastic shape memory alloy (SMA) fibers with their nonlinear elastic behavior as reinforcement in the composite could potentially provide a solution for this problem. Small diameter SMA wires are coupled with polymer matrix to produce SMA–FRP composite, which is sought in this research as reinforcing bars. SMA–FRP bars are sought in this study to enhance the seismic performance of reinforced concrete (RC) moment resisting frames (MRFs) in terms of reducing their residual inter-story drifts while still maintaining the elastic characteristics associated with conventional FRP. Three story one bay and six story two bay RC MRF prototype structures are designed with steel, SMA–FRP and glass–FRP reinforcement. The incremental dynamic analysis technique is used to investigate the behaviors of the two frames with the three different reinforcement types under a suite of ground motion records. It is found that the frames with SMA–FRP composite reinforcement exhibit higher performance levels including lower residual inter-story drifts, high energy dissipation and thus lower damage, which are important for structures in highly seismic zones. (paper)

  6. The effect of nylon nanofibers on the dynamic behaviour and the delamination resistance of GFRP composites

    Directory of Open Access Journals (Sweden)

    Garcia Cristobal

    2018-01-01

    Full Text Available Vibrations are responsible for a considerable number of accidents in aircrafts, bridges and other civil engineering structures. Therefore, there is a need to reduce the vibrations on structures made of composite materials. Delamination is a particularly dangerous failure mode for composite materials because delaminated composites can lose up to 60% of their strength and stiffness and still remain unchanged. One of the methods to suppress vibrations and preventing delamination is to incorporate nanofibers into the composite laminates. The aim of the present work is to investigate how nylon nanofibers affect the dynamic behaviour and delamination resistance of glass fibre reinforced polymer (GFRP composites. Experiments and numerical simulations using finite element modelling (FEM analysis are used to estimate the natural frequencies, the damping ratio and inter-laminar strength in GFRP composites with and without nylon nanofibers. It is found that the natural frequencies of the nylon nano-modified composites do not change significantly as compared to the traditional composites. However, nano-modified composites demonstrated a considerable increase in damping ratio and inter-laminar shear strength due to the incorporation of nylon nanofibers. This work contributes to the knowledge about the mechanical and dynamic properties of glass fibre reinforced polymer (GFRP composites with nylon nanofibers.

  7. Experimental and Numerical Analysis of Damage in Woven GFRP Composites Under Large-deflection Bending

    Science.gov (United States)

    Ullah, Himayat; Harland, Andy R.; Silberschmidt, Vadim V.

    2012-10-01

    Textile-reinforced composites such as glass fibre-reinforced polymer (GFRP) used in sports products can be exposed to different in-service conditions such as large bending deformation and multiple impacts. Such loading conditions cause high local stresses and strains, which result in multiple modes of damage and fracture in composite laminates due to their inherent heterogeneity and non-trivial microstructure. In this paper, various damage modes in GFRP laminates are studied using experimental material characterisation, non-destructive micro-structural damage evaluation and numerical simulations. Experimental tests are carried out to characterise the behaviour of these materials under large-deflection bending. To obtain in-plane shear properties of laminates, tensile tests are performed using a full-field strain-measurement digital image correlation technique. X-ray micro computed tomography (Micro CT) is used to investigate internal material damage modes - delamination and cracking. Two-dimensional finite element (FE) models are implemented in the commercial code Abaqus to study the deformation behaviour and damage in GFRP. In these models, multiple layers of bilinear cohesive-zone elements are employed to study the onset and progression of inter-ply delamination and intra-ply fabric fracture of composite laminate, based on the X-ray Micro CT study. The developed numerical models are capable to simulate these features with their mechanisms as well as subsequent mode coupling observed in tests and Micro CT scanning. The obtained results of simulations are in agreement with experimental data.

  8. Demonstration test on manufacturing steel bars for concrete reinforcement for recycling of reactor decommissioning metal scrap

    International Nuclear Information System (INIS)

    Sakurai, D.; Anabuki, Y.

    1993-01-01

    To prove the possibility of recycling the steel scrap resulting from decommissioning of a nuclear power plant, this salvaged steel would be formed into steel bars for concrete reinforcement, as the restricted use and limited use at nuclear plants. The shifting behavior of radioactive isotopes (RI) in the melting process was confirmed through the laboratory hot test using the RI. Then, the demonstration cold test for steel bars for reinforcement using the nonradioactive isotope was conducted in on-line production facilities. In this test the quality of steel bars and uniform distribution of RI were proven and material balance and operational data were obtained. These data show the recycling to steel bars for concrete reinforcement is applicable from economical and safety aspects

  9. Seismic Behavior and Retrofit of Concrete Columns of Old R.C. Buildings Reinforced With Plain Bars

    International Nuclear Information System (INIS)

    Marefat, M. S.; Arani, K. Karbasi; Shirazi, S. M. Hassanzadeh; Amrollahi, A.

    2008-01-01

    Seismic rehabilitation of old buildings has been a major challenge in recent years. The first step in seismic rehabilitation is evaluation of the existing capacity and the seismic behaviour. For investigation of the seismic behaviour of RC members of a real old building in Iran which has been designed and constructed by European engineers in 1940, three half-scale column specimens reinforced with plain bars have been tested. The tests indicate significant differences between the responses of specimens reinforced by plain bars relative to those reinforced by deformed bars. A regular pattern of cracking and a relatively brittle behaviour was observed while a relatively large residual strength appeared after sudden drop of initial strength and stiffness due to slip of longitudinal bars

  10. Modal parameter identification of all-GFRP composite cable-stayed footbridge in Denmark

    Directory of Open Access Journals (Sweden)

    Górski Piotr

    2017-01-01

    Full Text Available The aim of this paper is to investigate of dynamic characteristics of cable-stayed Fiberline Bridge in Kolding, Denmark, made entirely of Glass Fiber Reinforced Polymer (GFRP composite. During examination based on in situ free-decay measurements and using accelerometers under human jumping the primary five natural frequencies, corresponding mode shapes and damping ratios of the footbridge were identified. The Peak Picking (PP and Frequency Domain Decomposition (FDD approaches were applied to identify the natural frequencies and mode shapes. The corresponding damping ratios were extracted by a linear regression on the extremes of modal decays. The estimated damping ratios were compared with published data for selected footbridges made of various conventional materials. The obtained experimental results provide a relevant data regarding the dynamic response prediction or structural health monitoring of all-GFRP composite footbridges.

  11. Finite Element Analysis of IPS Empress II Ceramic Bridge Reinforced by Zirconia Bar.

    Science.gov (United States)

    Kermanshah, H; Bitaraf, T; Geramy, A

    2012-01-01

    The aim of this study was to determine the effect of trenched zirconia bar on the von Mises stress distribution of IPS -Empress II core ceramics. The three-dimensional model including a three-unit bridge from the second premolar to the second molar was designed. The model was reinforced with zirconia bar (ZB), zirconia bar with vertical trench (VZB) and zirconia bar with horizontal trench (HZB) (cross sections of these bars were circular). The model without zirconia bar was designed as the control. The bridges were loaded by 200 N and 500 N on the occlusal surface at the middle of the pontic component and von Mises stresses were evaluated along a defined path. IN THE CONNECTOR AREA, VON MISES STRESS IN MPA WERE APPROXIMATELY IDENTICAL IN THE SPECIMENS WITH ZB (AT MOLAR CONNECTOR (MC): 4.75 and at premolar connector (PC): 6.40) and without ZB (MC: 5.50, PC: 6.68), and considerable differences were not recognized. Whereas, Von-Mises stress (MPa) in the specimens with horizontal trenched Zirconia bar (HZB) (MC: 3.91, PC: 2.44) and Vertical trenched Zirconia bar (VZB) (MC: 2.53, PC: 2.56) was decreased considerably. Embeded trenched zirconia bar could reinforce IPS-Empress II at the connector area which is a main failure region in all ceramic fixed partial dentures.

  12. Design and development of solid carbide step drill K34 for machining of CFRP and GFRP composite laminates

    Science.gov (United States)

    Rangaswamy, T.; Nagaraja, R.

    2018-04-01

    The Study focused on design and development of solid carbide step drill K34 to drill holes on composite materials such as Carbon Fiber Reinforced Plastic (CFRP) and Glass Fiber Reinforced Plastic (GFRP). The step drill K34 replaces step wise drilling of diameter 6.5mm and 9 mm holes that reduces the setup time, cutting speed, feed rate cost, delamination and increase the production rate. Several researchers have analyzed the effect of drilling process on various fiber reinforced plastic composites by carrying out using conventional tools and machinery. However, this process operation can lead to different kind of damages such as delamination, fiber pullout, and local cracks. To avoid the problems encountered at the time of drilling, suitable tool material and geometry is essential. This paper deals with the design and development of K34 Carbide step drill used to drill holes on CFRP and GFRP laminates. An Experimental study carried out to investigate the tool geometry, feed rate and cutting speed that avoids delamination and fiber breakage.

  13. Recycled Glass Fiber Reinforced Polymer Composites Incorporated in Mortar for Improved Mechanical Performance

    Science.gov (United States)

    2017-12-11

    Glass fiber reinforced polymer (GFRP) recycled from retired wind turbines was implemented in mortar as a volumetric replacement of sand during the two phases of this study. In Phase I, the mechanically refined GFRP particle sizes were sieved for four...

  14. Potentialities of infrared thermography to assess damage in bonding between concrete and GFRP

    Directory of Open Access Journals (Sweden)

    M. M. CALDEIRA

    Full Text Available This paper demonstrates the application of the active infrared thermography to detect damage in bonding between concrete and glass fiber reinforced polymer (GFRP. Specimens of concrete and mortar with GFRP externally bonded were prepared and at their interfaces were inserted polystyrene discs to simulate damages. The samples were divided into two groups. In group 1, one sample was correctly bonded by a GFRP plate to the concrete, but in the other three were inserted polystyrene discs which had different diameters to simulate damages in bonding. In group 2, all of the samples contained identical polystyrene discs at their interfaces, but the total thickness of each specimen was different, because the objective was to evaluate the ability of the camera to capture the simulated damage in depth. The experimental procedure was divided into two stages. In the first stage, four types of heating were used to heat samples of group 1: incandescent lamp, kiln, blended lamp and fan heater. Thus, it was possible to detect the damage and to observe its format and length. It was noticed that the infrared images are different depending on the heat source incident on the specimen. Therefore, group 2 was tested only for the more efficient heating (incandescent lamp. In the second stage, the infrared equipment was tested. Some of the parameters that must be inserted in the camera were varied in order to understand their influence on image formation. The results show the effectiveness of infrared thermography to assess adherence in GFRP/concrete interface. In the present work, the best results were obtained when the image is captured towards GFRP/concrete and using incandescent lamp. It was observed that the image and measured temperature suffer significant distortion when a false value was inserted for the parameter emissivity.

  15. Structural Analysis of Basalt Fiber Reinforced Plastic Wind Turbine Blade

    Directory of Open Access Journals (Sweden)

    Mengal Ali Nawaz

    2014-07-01

    Full Text Available In this study, Basalt fiber reinforced plastic (BFRP wind turbine blade was analyzed and compared with Glass fiber reinforced plastic blade (GFRP. Finite element analysis (FEA of blade was carried out using ANSYS. Data for FEA was obtained by using rule of mixture. The shell element in ANSYS was used to simulate the wind turbine blade and to conduct its strength analysis. The structural analysis and comparison of blade deformations proved that BFRP wind turbine blade has better strength compared to GFRP wind turbine blade.

  16. Shear Strengthening of RC Beams Using Sprayed Glass Fiber Reinforced Polymer

    Directory of Open Access Journals (Sweden)

    Sayed Mohamad Soleimani

    2012-01-01

    Full Text Available The effectiveness of externally bonded sprayed glass fiber reinforced polymer (Sprayed GFRP in shear strengthening of RC beams under quasi-static loading is investigated. Different techniques were utilized to enhance the bond between concrete and Sprayed GFRP, involving the use of through bolts and nuts paired with concrete surface preparation through sandblasting and through the use of a pneumatic chisel prior to Sprayed GFRP application. It was found that roughening the concrete surface using a pneumatic chisel and using through bolts and nuts were the most effective techniques. Also, Sprayed GFRP applied on 3 sides (U-shaped was found to be more effective than 2-sided Sprayed GFRP in shear strengthening. Sprayed GFRP increased the shear load-carrying capacity and energy absorption capacities of RC beams. It was found that the load-carrying capacity of strengthened RC beams was related to an effective strain of applied Sprayed GFRP. This strain was related to Sprayed GFRP configuration and the technique used to enhance the concrete-FRP bond. Finally, an equation was proposed to calculate the contribution of Sprayed GFRP in the shear strength of an RC beam.

  17. Mechanical Performance versus Corrosion Damage Indicators for Corroded Steel Reinforcing Bars

    Directory of Open Access Journals (Sweden)

    Silvia Caprili

    2015-01-01

    Full Text Available The experimental results of a testing campaign including tensile and low-cycle fatigue tests on different reinforcing steel bar types in the as-delivered and corroded condition are presented. Experimental data were statistically analyzed adopting ANOVA technique; Performance Indicators (PIs, describing the mechanical performance characteristics of reinforcements, and Corrosion Damage Indicators (CDIs, describing the detrimental effects of corrosion phenomena, were determined and correlated in order to evaluate the influence of corrosion on the behaviour of reinforcing steels, providing useful information for designers in addition to what is presented in current standards.

  18. Buckling model of longitudinal reinforcing bars under reverse cyclic load; Koban kurikaeshi kajuka ni okeru chukin no zakutsu model

    Energy Technology Data Exchange (ETDEWEB)

    Murayama, Y.; Suda, K.; Ichinomiya, T.; Shinbo, H. [Kajima Corp., Tokyo (Japan)

    1994-10-31

    For RC (reinforced concrete) columns such as towers of long-span cable-stayed bridges or high-rise piers, there is desired development of an analytical method including a method of arranging reinforcing bars for increasing their ductility against strong earthquake motion. For this, it is necessary to investigate their characteristics after their being rendered to maximum load and their final states, and hence there must be newly investigated the properties of a plastic hinge formed on the bottom of the column, particularly determination of the buckling point of reinforcing bars and a hysteresis model after the buckling. In this study, there is developed a direct method of measuring the stress of reinforcing bars embedded in a model specimen which is conventionally difficult to be measured, and there is investigated the stress-strain hysteresis of the bars before and after the buckling thereof. The principle of the method of measuring the stress is such that only a local minimum portion of objective reinforcing bars is rendered to rf quenching, and a distortion gauge is sticked to the center of the quenching. This is based upon a fact that that portion keeps a linear relationship between the stress and the strain even if a host material is yielded. On the basis of an experimental result, a mechanism of buckling of these bars is clarified and a buckling model of the reinforcing bars at the plastic hinge. 6 refs., 15 figs., 2 tabs.

  19. Finite Element Analysis of IPS –Empress II Ceramic Bridge Reinforced by Zirconia Bar

    Directory of Open Access Journals (Sweden)

    Allahyar Geramy

    2012-01-01

    Full Text Available Objective: The aim of this study was to determine the effect of trenched zirconia bar on the von Mises stress distribution of IPS –Empress II core ceramics.Material and Methods: The three-dimensional model including a three-unit bridge from the second premolar to the second molar was designed. The model was reinforced with zirconia bar (ZB, zirconia bar with vertical trench (VZB, and zirconia bar with horizontal trench (HZB (cross sections of these bars were circular. The model without zirconia bar was designed as the control. The bridges were loaded by 200 N and 500 N on the occlusal surface at the middle of the pontic component, and Von-Mises stresses were evaluated along a defined path.Result: In the connector area, VonMises stress in MPa were approximately identical in the specimens with ZB (at molar connector (MC: 4.75, and at premolar connector (PC: 6.40 and without ZB (MC: 5.50, PC: 6.68, and considerable differences were not recognized. Whereas, Von-Mises stress (MPa in the specimens with horizontal trenched Zirconia bar (HZB (MC: 3.91, PC: 2.44 and Vertical trenched Zirconia bar (VZB (MC: 2.53, PC: 2.56 was decreased considerably.Conclusion: Embeded trenched zirconia bar could reinforce IPS-Empress II at the connector area which is a main failure region in all ceramic fixed partial dentures.

  20. Effect of intercritical heat treatment on mechanical properties of reinforcing steel bars

    International Nuclear Information System (INIS)

    Abro, M.I.; Memon, R.A.; Soomro, I.A.; Aftab, U.

    2017-01-01

    Intercritical heat treatments attempts were made to enhance the mechanical properties of reinforcing steel bars milled from scrap metal. For this, two grades of steel bars were obtained from different steel mills and their mechanical properties that include hardness, ultimate tensile strength, and percent elongation before and after intercritical heat treatment were determined. Results indicated that 25.5 and 17.6%, improvements in UTS (Ultimate Tensile Strength) and 18.8 and 14.3% improvement in percent elongation in two grades of reinforcing steel samples containing 0.17 and 0.24% carbon respectively was achieved while heating at 750 degree C for 2h. Appreciable improvement in the mechanical properties was noted due to birth of sufficient quantity of martensite along with ferrite. (author)

  1. Mechanical Characteristics Analysis of Surrounding Rock on Anchor Bar Reinforcement

    Science.gov (United States)

    Gu, Shuan-cheng; Zhou, Pan; Huang, Rong-bin

    2018-03-01

    Through the homogenization method, the composite of rock and anchor bar is considered as the equivalent material of continuous, homogeneous, isotropic and strength parameter enhancement, which is defined as reinforcement body. On the basis of elasticity, the composite and the reinforcement are analyzed, Based on strengthening theory of surrounding rock and displacement equivalent conditions, the expression of reinforcement body strength parameters and mechanical parameters is deduced. The example calculation shows that the theoretical results are close to the results of the Jia-mei Gao[9], however, closer to the results of FLAC3D numerical simulation, it is proved that the model and surrounding rock reinforcement body theory are reasonable. the model is easy to analyze and calculate, provides a new way for determining reasonable bolt support parameters, can also provides reference for the stability analysis of underground cavern bolting support.

  2. Structural performance of circular columns confined by recycled GFRP stirrups and exposed to severe conditions

    Directory of Open Access Journals (Sweden)

    Mohamed S. Sayed

    2012-08-01

    Full Text Available Since 1980, Egyptian government investment has been directed to the infrastructure projects. Water supply and water drainage networks are among those projects which are very costly; therefore they are designed with a life span of about one hundred years. There is a new trend toward the use of durable and maintenance free systems. The “GFRP” pipes are one of the economic solutions if the project life span is taken into consideration. A number of investors currently produce the “GFRP” pipes in the Egyptian market and although they follow the latest technologies in their production lines, they still suffer 2–5% deficiency of their produced pipes which consequently regarded as rejected pipes. This percentage has a negative impact on the environmental and economical issues. This research is a trial to investigate the behavior of circular columns confined by GFRP stirrups and exposed to severe conditions. A number of waste pipes were randomly selected and sliced to be used as circular column transverse reinforcement. An experimental program consisting of ten short circular columns was designed to study the effect of corrosion, high degrees of temperature, and sulfate attack on the structural behavior of the axially loaded short circular columns. The experimental results showed that columns laterally reinforced by GFRP slices have a comparable behavior to conventionally reinforced concrete columns especially for those columns exposed to corrosion and sulfate attack.

  3. Technical Developments and Trends of Earthquake Resisting High-Strength Reinforcing Steel Bars

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Byoungchul [Seoul National University of Science and Technology, Seoul (Korea, Republic of); Shim, Jae-Hyeok [Korea Institute of Science and Technology, Seoul (Korea, Republic of); Lee, Myoung-Gyu; Lee, Joonho [Korea University, Seoul (Korea, Republic of); Jung, Jun-Ho [Hyundai Steel, Incheon (Korea, Republic of); Kim, Bo-Sung [Daehan Steel, Busan (Korea, Republic of); Won, Sung-Bin [Dongkuk Steel, Kyungju (Korea, Republic of)

    2016-12-15

    Since reconstruction of old town in Korea requires high-rise and seismic design construction, many attentions have been paid to high strength seismic reinforced steel bar. In the present paper, technical developments and trends are summarized for developing next-generation seismic reinforced steel bar of grade 700 MPa. Steelmaking process requires high energy efficiency and refining ability. Effects of alloying elements are explained, and alloy design based on computational thermodynamics is introduced. On the other hand, it is considered that grain size refinement by the controlled rolling and low temperature transformation structures formed by the accelerated cooling are effective to obtain acceptable mechanical properties with high strength. Finite element simulation analysis is also useful to understand plastic deformation by rolling, internal and external heat transfer, and corresponding phase transformation of austenite phase to various low-temperature transformation structures.

  4. Technical Developments and Trends of Earthquake Resisting High-Strength Reinforcing Steel Bars

    International Nuclear Information System (INIS)

    Hwang, Byoungchul; Shim, Jae-Hyeok; Lee, Myoung-Gyu; Lee, Joonho; Jung, Jun-Ho; Kim, Bo-Sung; Won, Sung-Bin

    2016-01-01

    Since reconstruction of old town in Korea requires high-rise and seismic design construction, many attentions have been paid to high strength seismic reinforced steel bar. In the present paper, technical developments and trends are summarized for developing next-generation seismic reinforced steel bar of grade 700 MPa. Steelmaking process requires high energy efficiency and refining ability. Effects of alloying elements are explained, and alloy design based on computational thermodynamics is introduced. On the other hand, it is considered that grain size refinement by the controlled rolling and low temperature transformation structures formed by the accelerated cooling are effective to obtain acceptable mechanical properties with high strength. Finite element simulation analysis is also useful to understand plastic deformation by rolling, internal and external heat transfer, and corresponding phase transformation of austenite phase to various low-temperature transformation structures.

  5. Parametric Study of End Milling Glass Fibre Reinforced Composites

    International Nuclear Information System (INIS)

    Azmi, Azwan I.; Lin, Richard J. T.; Bhattacharyya, Debes

    2011-01-01

    This paper discusses the application of Taguchi 'Design of Experiment' method to investigate the effects of end milling parameters on machinability characteristics of unidirectional E-glass fibre reinforced polymer (GFRP) composites. A series of milling experiments were conducted using tungsten carbide end milling cutters at various spindle speeds, feed rates and depths of cut. Taguchi analysis was carried out and the signal to noise (S/N) ratio with analysis of variance (ANOVA) was employed to analyse the effects of those parameters on GFRP machinability. Overall, the results of the current investigations present some desirable combinations of the machining parameters that can further enhance the end milling machinability characteristics to suit the final requirements of the finished GFRP products.

  6. Investigation of the resistance of several new metallic reinforcing bars to chloride-induced corrosion in concrete.

    Science.gov (United States)

    2003-01-01

    The Virginia Department of Transportation recently initiated a search for metallic reinforcing bars that are not only more durable and corrosion resistant than the epoxy-coated bars currently used, but also economical. In the last few years, several ...

  7. Feasibility of externally activated self-repairing concrete with epoxy injection network and Cu-Al-Mn superelastic alloy reinforcing bars

    International Nuclear Information System (INIS)

    Pareek, Sanjay; Shrestha, Kshitij C; Araki, Yoshikazu; Suzuki, Yusuke; Omori, Toshihiro; Kainuma, Ryosuke

    2014-01-01

    This paper studies the effectiveness of an externally activated self-repairing technique for concrete members with epoxy injection network and Cu-Al-Mn superelastic alloy (SEA) reinforcing bars (rebars). Compared to existing crack self-repairing and self-healing techniques, the epoxy injection network has the following strengths: (1) Different from the self-repairing methods using brittle containers or tubes for adhesives, the proposed self-repair process can be performed repeatedly and is feasible for onsite concrete casting. (2) Different from the autogenic self-healing techniques, full strength recovery can be achieved in a shorter time period without the necessity of water. This paper attempts to enhance the self-repairing capability of the epoxy injection network by reducing residual cracks by using cost-effective Cu-based SEA bars. The effectiveness of the present technique is examined using concrete beam specimens reinforced by 3 types of bars. The first specimen is reinforced by steel deformed bars, the second by steel threaded bars, and finally by SEA threaded rebars. The tests were performed with a 3 point cyclic loading with increasing amplitude. From the test results, effective self-repairing was confirmed for small deformation levels irrespective of the reinforcement types. Effective self-repairing was observed in the SEA reinforced specimen even under much larger deformations. Nonlinear finite element analysis was performed to confirm the experimental findings. (paper)

  8. 78 FR 73838 - Steel Concrete Reinforcing Bar From Turkey: Postponement of Preliminary Determination in the...

    Science.gov (United States)

    2013-12-09

    ... DEPARTMENT OF COMMERCE International Trade Administration [C-489-819] Steel Concrete Reinforcing... countervailing duty investigation on steel concrete reinforcing bar from Turkey.\\1\\ The original signature date... signature date for the preliminary determination was revised to December 16, 2013.\\3\\ \\1\\ See Steel Concrete...

  9. Experimental and analytical investigation of reinforced high strength concrete continuous beams strengthened with fiber reinforced polymer

    International Nuclear Information System (INIS)

    Akbarzadeh, H.; Maghsoudi, A.A.

    2010-01-01

    Carbon and glass fiber reinforced polymer (CFRP and GFRP) are two materials suitable for strengthening the reinforced concrete (RC) beams. Although many in situ RC beams are of continuous constructions, there has been very limited research on the behavior of such beams with externally applied FRP laminate. In addition, most design guidelines were developed for simply supported beams with external FRP laminates. This paper presents an experimental program conducted to study the flexural behavior and redistribution in moment of reinforced high strength concrete (RHSC) continuous beams strengthened with CFRP and GFRP sheets. Test results showed that with increasing the number of CFRP sheet layers, the ultimate strength increases, while the ductility, moment redistribution, and ultimate strain of CFRP sheet decrease. Also, by using the GFRP sheet in strengthening the continuous beam reduced loss in ductility and moment redistribution but it did not significantly increase ultimate strength of beam. The moment enhancement ratio of the strengthened continuous beams was significantly higher than the ultimate load enhancement ratio in the same beam. An analytical model for moment-curvature and load capacity are developed and used for the tested continuous beams in current and other similar studies. The stress-strain curves of concrete, steel and FRP were considered as integrity model. Stress-strain model of concrete is extended from Oztekin et al.'s model by modifying the ultimate strain. Also, new parameters of equivalent stress block are obtained for flexural calculation of RHSC beams. Good agreement between experiment and prediction values is achieved.

  10. A new type of smart basalt fiber-reinforced polymer bars as both reinforcements and sensors for civil engineering application

    Science.gov (United States)

    Tang, Yongsheng; Wu, Zhishen; Yang, Caiqian; Wu, Gang; Shen, Sheng

    2010-11-01

    In this paper, a new type of smart basalt fiber-reinforced polymer (BFRP) bar is developed and their sensing performance is investigated by using the Brillouin scattering-based distributed fiber optic sensing technique. The industrial manufacturing process is first addressed, followed by an experimental study on the strain, temperature and fundamental mechanical properties of the BFRP bars. The results confirm the superior sensing properties, in particular the measuring accuracy, repeatability and linearity through comparing with bare optical fibers. Results on the mechanical properties show stable elastic modulus and high ultimate strength. Therefore, the smart BFRP bar has potential applications for long-term structural health monitoring (SHM) as embedded sensors as well as strengthening and upgrading structures. Moreover the coefficient of thermal expansion for smart BFRP bars is similar to the value for concrete.

  11. A new type of smart basalt fiber-reinforced polymer bars as both reinforcements and sensors for civil engineering application

    International Nuclear Information System (INIS)

    Tang, Yongsheng; Wu, Zhishen; Yang, Caiqian; Wu, Gang; Shen, Sheng

    2010-01-01

    In this paper, a new type of smart basalt fiber-reinforced polymer (BFRP) bar is developed and their sensing performance is investigated by using the Brillouin scattering-based distributed fiber optic sensing technique. The industrial manufacturing process is first addressed, followed by an experimental study on the strain, temperature and fundamental mechanical properties of the BFRP bars. The results confirm the superior sensing properties, in particular the measuring accuracy, repeatability and linearity through comparing with bare optical fibers. Results on the mechanical properties show stable elastic modulus and high ultimate strength. Therefore, the smart BFRP bar has potential applications for long-term structural health monitoring (SHM) as embedded sensors as well as strengthening and upgrading structures. Moreover the coefficient of thermal expansion for smart BFRP bars is similar to the value for concrete

  12. Experimental Investigation on the Durability of Glass Fiber-Reinforced Polymer Composites Containing Nanocomposite

    Directory of Open Access Journals (Sweden)

    Weiwen Li

    2013-01-01

    Full Text Available Nanoclay layers incorporated into polymer/clay nanocomposites can inhibit the harmful penetration of water and chemicals into the material, and thus the durability of glass fiber-reinforced polymer (GFRP composites should be enhanced by using polymer/clay nanocomposite as the matrix material. In this study, 1.5 wt% vinyl ester (VE/organoclay and 2 wt% epoxy (EP/organoclay nanocomposites were prepared by an in situ polymerization method. The dispersion states of clay in the nanocomposites were studied by performing XRD analysis. GFRP composites were then fabricated with the prepared 1.5 wt% VE/clay and 2.0 wt% EP/clay nanocomposites to investigate the effects of a nanocomposite matrix on the durability of GFRP composites. The durability of the two kinds of GFRP composites was characterized by monitoring tensile properties following degradation of GFRP specimens aged in water and alkaline solution at 60°C, and SEM was employed to study fracture behaviors of aged GFRP composites under tension. The results show that tensile properties of the two types of GFRP composites with and without clay degrade significantly with aging time. However, the GFRP composites with nanoclay show a lower degradation rate compared with those without nanoclay, supporting the aforementioned hypothesis. And the modification of EP/GFRP enhanced the durability more effectively.

  13. Preparation, mechanical, and in vitro properties of glass fiber-reinforced polycarbonate composites for orthodontic application.

    Science.gov (United States)

    Tanimoto, Yasuhiro; Inami, Toshihiro; Yamaguchi, Masaru; Nishiyama, Norihiro; Kasai, Kazutaka

    2015-05-01

    Generally, orthodontic treatment uses metallic wires made from stainless steel, cobalt-chromium-nickel alloy, β-titanium alloy, and nickel-titanium (Ni-Ti) alloy. However, these wires are not esthetically pleasing and may induce allergic or toxic reactions. To correct these issues, in the present study we developed glass-fiber-reinforced plastic (GFRP) orthodontic wires made from polycarbonate and E-glass fiber by using pultrusion. After fabricating these GFRP round wires with a diameter of 0.45 mm (0.018 inch), we examined their mechanical and in vitro properties. To investigate how the glass-fiber diameter affected their physical properties, we prepared GFRP wires of varying diameters (7 and 13 µm). Both the GFRP with 13-µm fibers (GFRP-13) and GFRP with 7 µm fibers (GFRP-7) were more transparent than the metallic orthodontic wires. Flexural strengths of GFRP-13 and GFRP-7 were 690.3 ± 99.2 and 938.1 ± 95.0 MPa, respectively; flexural moduli of GFRP-13 and GFRP-7 were 25.4 ± 4.9 and 34.7 ± 7.7 GPa, respectively. These flexural properties of the GFRP wires were nearly equivalent to those of available Ni-Ti wires. GFRP-7 had better flexural properties than GFRP-13, indicating that the flexural properties of GFRP increase with decreasing fiber diameter. Using thermocycling, we found no significant change in the flexural properties of the GFRPs after 600 or 1,200 cycles. Using a cytotoxicity detection kit, we found that the glass fiber and polycarbonate components comprising the GFRP were not cytotoxic within the limitations of this study. We expect this metal-free GFRP wire composed of polycarbonate and glass fiber to be useful as an esthetically pleasing alternative to current metallic orthodontic wire. © 2014 Wiley Periodicals, Inc.

  14. Tensile strength/yield strength (TS/YS) ratios of high-strength steel (HSS) reinforcing bars

    Science.gov (United States)

    Tavio, Anggraini, Retno; Raka, I. Gede Putu; Agustiar

    2018-05-01

    The building codes such as American Concrete Institute (ACI) 318M-14 and Standard National Indonesia (SNI) 2847:2013 require that the ratio of tensile strength (TS) and yield strength (YS) should not less than 1.25. The requirement is based on the assumption that a capability of a structural member to develop inelastic rotation capacity is a function of the length of the yield region. This paper reports an investigation on various steel grades, namely Grades 420, 550, 650, and 700 MPa, to examine the impact of different TS/YS ratios if it is less or greater than the required value. Grades 550, 650, and 700 MPa were purposely selected with the intention to examine if these higher grades are still promising to be implemented in special structural systems since they are prohibited by the building codes for longitudinal reinforcement, whereas Grade 420 MPa bars are the maximum limit of yield strength of reinforcing bars that is allowable for longitudinal reinforcement of special structural systems. Tensile tests of these steel samples were conducted under displacement controlled mode to capture the complete stress-strain curves and particularly the post-yield response of the steel bars. From the study, it can be concluded that Grade 420 performed higher TS/YS ratios and they were able to reach up to more than 1.25. However, the High Strength Still (HSS) bars (Grades 550, 600, and 700 MPa) resulted in lower TS/YS ratios (less than 1.25) compared with those of Grade 420 MPa.

  15. Estudio experimental de la adherencia entre laminados de GFRP y el hormigón

    OpenAIRE

    Albiol Ibáñez, José Ramón

    2016-01-01

    [EN] At present, hybrid structures in flexural elements are being gradually incorporated in the field of civil and building structures. The low weight and high durability of these structures make use viable. Hybrid structures are usually composed of polymeric materials reinforced with glass or carbon fibers (GFRP or CFRP) in structural shapes of any type of section, in I, in box, trough-shaped, as elements working in tension, and the concrete in the compressed head of the resistant section. D...

  16. Breakdown tests of glass fibre reinforced polymers (GFRP) as part of improved lightning protection of wind turbine blades

    DEFF Research Database (Denmark)

    Madsen, Søren Find; Holbøll, Joachim; Henriksen, Mogens

    2004-01-01

    the test methods and the results are evaluated. The different results are compared with respect to the GFRP materials' overall thicknesses, thickness of laminates and thickness of coatings. Finally, some general conclusions and different statements on how to manufacture specimens with minimum likelihood...

  17. Seismic damage sensing of bridge structures with TRIP reinforcement steel bars

    Science.gov (United States)

    Adachi, Yukio; Unjoh, Shigeki

    2001-07-01

    Intelligent reinforced concrete structures with transformation-induced-plasticity (TRIP) steel rebars that have self-diagnosis function are proposed. TRIP steel is special steel with Fe-Cr based formulation. It undergoes a permanent change in crystal structure in proportion to peak strain. This changes from non-magnetic to magnetic steel. By using the TRIP steel rebars, the seismic damage level of reinforced concrete structures can be easily recognized by measuring the residual magnetic level of the TRIP rebars, that is directly related to the peak strain during a seismic event. This information will be most helpful for repairing the damaged structures. In this paper, the feasibility of the proposed intelligent reinforced concrete structure for seismic damage sensing is experimentally studied. The relation among the damage level, peak strain of rebars, and residual magnetic level of rebars of reinforced concrete beams implemented with TRIP steel bars was experimentally studied. As the result of this study, this intelligent structure can diagnose accumulated strain/damage anticipated during seismic event.

  18. LOSS FACTOR AND DYNAMIC YOUNG MODULUS DETERMINATION FOR COMPOSITE SANDWICH BARS REINFORCED WITH STEEL FABRIC

    Directory of Open Access Journals (Sweden)

    Cosmin-Mihai MIRIŢOIU

    2015-05-01

    Full Text Available In this paper I have build some composite sandwich bars. For these bars I have determined the dynamic response by recording their free vibrations. These bars have the core made of polypropylene honeycomb with upper and lower layers reinforced with steel wire mesh. For these bars I have determined the the eigenfrequency of the first eigenmode in this way: the bar was embedded at one end and free at the other where there was placed an accelerometer at 10 mm distance from the edge and I applied an initial force at the free end. I have determined the eigenfrequency because I will use its values for the loss factor and dynamic Young modulus determination.

  19. Effect of fabric structure and polymer matrix on flexural strength, interlaminar shear stress, and energy dissipation of glass fiber-reinforced polymer composites

    Science.gov (United States)

    We report the effect of glass fiber structure and the epoxy polymer system on the flexural strength, interlaminar shear stress (ILSS), and energy absorption properties of glass fiber-reinforced polymer (GFRP) composites. Four different GFRP composites were fabricated from two glass fiber textiles of...

  20. New recycling approaches for thermoset polymeric composite wastes – an experimental study on polyester based concrete materials filled with fibre reinforced plastic recyclates

    OpenAIRE

    Ribeiro, M. C. S.; Fiúza, António; Meira Castro, A C; Dinis, M. L.; Silva, Francisco J. G.; Meixedo, João Paulo

    2011-01-01

    In this study, a new waste management solution for thermoset glass fibre reinforced polymer (GFRP) based products was assessed. Mechanical recycling approach, with reduction of GFRP waste to powdered and fibrous materials was applied, and the prospective added-value of obtained recyclates was experimentally investigated as raw material for polyester based mortars. Different GFRP waste admixed mortar formulations were analyzed varying the content, between 4% up to 12% in we...

  1. The effect of ion implantation on the tribomechanical properties of carbon fibre reinforced polymers

    International Nuclear Information System (INIS)

    Mistica, R.; Sood, D.K.; Janardhana, M.N.

    1993-01-01

    Graphite fibre reinforced epoxy composite material (GFRP) is used extensively in the aerospace and other industries for structural application. The trend is to address the 20 to 30 year life endurance of this material in service. Mechanical joints in air crafts are exposed to dynamic loads during service and wear may be experienced by the composite material joint. Generally it has been shown that graphite fibre reinforced polymers have superior wear and friction properties as compared with the unfilled polymers. In the described experiment, ion implantation was used as a novel surface treatment. Wear and friction of a polymer composite material (GFRP) was studied and ion implantation was used in order to observe the effect on the tribomechanical properties of the material. It was found that ion implantation of C on GFRP sliding against Ti changes the tribological properties of the system, and in particular decreases the coefficient of friction and wear. 4 refs., 2 figs

  2. The effect of ion implantation on the tribomechanical properties of carbon fibre reinforced polymers

    Energy Technology Data Exchange (ETDEWEB)

    Mistica, R.; Sood, D.K. [Royal Melbourne Inst. of Tech., VIC (Australia); Janardhana, M.N. [Deakin University, Geelong, VIC (Australia). School of Engineering and Technology

    1993-12-31

    Graphite fibre reinforced epoxy composite material (GFRP) is used extensively in the aerospace and other industries for structural application. The trend is to address the 20 to 30 year life endurance of this material in service. Mechanical joints in air crafts are exposed to dynamic loads during service and wear may be experienced by the composite material joint. Generally it has been shown that graphite fibre reinforced polymers have superior wear and friction properties as compared with the unfilled polymers. In the described experiment, ion implantation was used as a novel surface treatment. Wear and friction of a polymer composite material (GFRP) was studied and ion implantation was used in order to observe the effect on the tribomechanical properties of the material. It was found that ion implantation of C on GFRP sliding against Ti changes the tribological properties of the system, and in particular decreases the coefficient of friction and wear. 4 refs., 2 figs.

  3. The effect of ion implantation on the tribomechanical properties of carbon fibre reinforced polymers

    Energy Technology Data Exchange (ETDEWEB)

    Mistica, R; Sood, D K [Royal Melbourne Inst. of Tech., VIC (Australia); Janardhana, M N [Deakin University, Geelong, VIC (Australia). School of Engineering and Technology

    1994-12-31

    Graphite fibre reinforced epoxy composite material (GFRP) is used extensively in the aerospace and other industries for structural application. The trend is to address the 20 to 30 year life endurance of this material in service. Mechanical joints in air crafts are exposed to dynamic loads during service and wear may be experienced by the composite material joint. Generally it has been shown that graphite fibre reinforced polymers have superior wear and friction properties as compared with the unfilled polymers. In the described experiment, ion implantation was used as a novel surface treatment. Wear and friction of a polymer composite material (GFRP) was studied and ion implantation was used in order to observe the effect on the tribomechanical properties of the material. It was found that ion implantation of C on GFRP sliding against Ti changes the tribological properties of the system, and in particular decreases the coefficient of friction and wear. 4 refs., 2 figs.

  4. Bond-Slip Behavior of Basalt Fiber Reinforced Polymer Bar in Concrete Subjected to Simulated Marine Environment: Effects of BFRP Bar Size, Corrosion Age, and Concrete Strength

    OpenAIRE

    Yongmin Yang; Zhaoheng Li; Tongsheng Zhang; Jiangxiong Wei; Qijun Yu

    2017-01-01

    Basalt Fiber Reinforced Polymer (BFRP) bars have bright potential application in concrete structures subjected to marine environment due to their superior corrosion resistance. Available literatures mainly focused on the mechanical properties of BFRP concrete structures, while the bond-slip behavior of BFRP bars, which is a key factor influencing the safety and service life of ocean concrete structures, has not been clarified yet. In this paper, effects of BFRP bars size, corrosion age, and c...

  5. Interface enhancement of glass fiber reinforced vinyl ester composites with flame-synthesized carbon nanotubes and its enhancing mechanism.

    Science.gov (United States)

    Liao, Lingmin; Wang, Xiao; Fang, Pengfei; Liew, Kim Meow; Pan, Chunxu

    2011-02-01

    Interface enhancement with carbon nanotubes (CNTs) provides a promising approach for improving shock strength and toughness of glass fiber reinforced plastic (GFRP) composites. The effects of incorporating flame-synthesized CNTs (F-CNTs) into GFRP were studied, including on hand lay-up preparation, microstructural characterization, mechanical properties, fracture morphologies, and theoretical calculation. The experimental results showed that: (1) the impact strength of the GFRP modified by F-CNTs increased by more than 15% over that of the GFRP modified by CNTs from chemical vapor deposition; and (2) with the F-CNT enhancement, no interfacial debonding was observed at the interface between the fiber and resin matrix on the GFRP fracture surface, which indicated strong adhesive strength between them. The theoretical calculation revealed that the intrinsic characteristics of the F-CNTs, including lower crystallinity with a large number of defects and chemical functional groups on the surface, promoted their surface activity and dispersibility at the interface, which improved the interfacial bond strength of GFRP.

  6. The Effect of Slamming Impact on Out-of-Autoclave Cured Prepregs of GFRP Composite Panels for Hulls

    OpenAIRE

    Suárez, J.C.; Townsend, P.; Sanz, E.; Ulzurrum, I. Diez de; Pinilla, P.

    2016-01-01

    This paper proposes a methodology that employs an experimental apparatus that reproduces, in pre-impregnated and cured out-of-autoclave Glass Fiber Reinforced Polymer (GFRP) panels, the phenomenon of slamming or impact on the bottom of a high-speed boat during planing. The pressure limits in the simulation are defined by employing a finite element model (FEM) that evaluates the forces applied by the cam that hits the panels in the apparatus via microdeformations obtained in the simulation. Th...

  7. Numerical Study on Section Constitutive Relations of Members Reinforced by Steel-BFRP Composite Bars

    Science.gov (United States)

    Xiao, Tongliang; Qiu, Hongxing

    2017-06-01

    Steel-Basalt FRP Composite Bar (S-BFCB) is a new kind of substitute material for longitudinal reinforcement, with high elastic modulus, stable post-yield stiffness and excellent corrosive resistance. Based on mechanical properties of S-BFCB and the plane cross-section assumption, the moment-curvature curves of beam and column members are simulated. Some parameters such as equivalent rebar ratio, postyeild stiffness, concrete strength and axial compression ratio of column were discussed. Results show that the constitutive relation of the cross section is similar with RC member in elastic and cracking stages, while different in post-yield stage. With the increase of postyeild stiffness ratio of composite bar, the ultimate bearing capacity of component improved observably, member may turn out over-reinforced phenomenon, concrete crushing may appear before the fibersarefractured. The effect of concrete strength increase in lower postyeild stiffness ratio is not obvious than in higher. The increase of axial compression ratio has actively influence on bearing capacity of column, but decreases on the ductility.

  8. 2.45 GHz Microwave Processing and Its Influence on Glass Fiber Reinforced Plastics

    Science.gov (United States)

    Zaremba, Swen

    2018-01-01

    During the production of fiber-reinforced composite materials, liquid resin is introduced into the fiber material and cured, i.e., hardened. An elevated temperature is needed for this curing. Microwave curing of composites has been investigated for some time, but it has mostly been done using small domestic or laboratory equipment. However, no investigation has been carried out using an industrial-sized chamber-microwave for glass fiber-reinforced plastic (GFRP). Here, we show that microwave curing produces laminates of the same quality as oven-cured ones. The study shows that, if the process is done right, GFRP samples can be produced with an industrial scale microwave. Even if not fully cured, microwave samples show a glass transition temperature measured with DMA (Tg-DMA) that is comparable to the Tg-DMA according to the proposed cure cycle on the data sheet. Specific microwave-cured configurations show better inter-laminar shear strength than oven specimens. The results show that microwave-based heat introduction can be a beneficial curing method for GFRP laminates. A microwave-optimized process is faster and leads to better mechanical properties. PMID:29783684

  9. Iowa state highway 92 over drainage ditch #25 : performance evaluation - galvanized reinforcing bars, Louisa County, Iowa.

    Science.gov (United States)

    2015-06-01

    Several strategies are available to the Iowa Department of Transportation (IaDOT) for limiting : deterioration due to chloride-induced corrosion of embedded reinforcing bars in concrete bridge decks. : While the method most commonly used throughout t...

  10. Study of the compressive behavior of short concrete columns confined by fiber reinforced composite

    International Nuclear Information System (INIS)

    Benzaid, Riad; Mesbah, Habib; Chikh, Nasr eddine

    2009-01-01

    Fiber reinforced polymer (FRP) composites are very attractive for use in civil engineering applications due to their high strength-to-weight and stiffness-to-weight ratios, corrosion resistance, light weight, and potentially high durability. There is a growing interest in the use of FRP for strengthening of concrete structures such as buildings, bridges, chimneys, etc. This is mainly due to their tailorable performance characteristics, ease of application, and low life cycle costs. The present paper deals with the analysis of experimental results, in terms of load carrying capacity and strains, obtained from tests on circular and square prismatic high strength concrete specimens, strengthened with external E-glass fiber reinforced polymer (GFRP). The parameters considered are the number of composite layers, the corner radius for square shape, and the relation of GFRP confinement with steel reinforcement. All the test specimens were loaded to failure in axial compression and the behavior of the specimens in the axial directions was investigated. The obtained results showed that the efficiency of the confinement was very sensitive to the specimen cross section geometry (circular and square) and the confining stress expressed in the number of the GFRP sheet layers applied. In square cross sections, the stress-strain curve was influenced by the radius to which the corners of the section are rounded off, in order to avoid the breakage of the fibers. (author)

  11. Development of a slim window frame made of glass fibre reinforced polyester

    DEFF Research Database (Denmark)

    Appelfeld, David; Hansen, Christian Skodborg; Svendsen, Svend

    2010-01-01

    This paper presents the development of an energy efficient window frame made of a glass fibre reinforced polyester (GFRP) material. Three frame proposals were considered. The energy and structural performances of the frames were calculated and compared with wooden and aluminium reference frames....... In order to estimate performances, detailed thermal calculations were performed in four successive steps including solar energy and light transmittance in addition to heat loss and supplemented with a simplified structural calculation of frame load capacity and deflection. Based on these calculations, we...... carried out an analysis of the potential energy savings of the frame. The calculations for a reference office building showed that the heating demand was considerably lower with a window made of GFRP than with the reference frames. It was found that GFRP is suitable for window frames, and windows made...

  12. Effect of severely thermal shocked MWCNT enhanced glass fiber reinforced polymer composite: An emphasis on tensile and thermal responses

    Science.gov (United States)

    Mahato, K. K.; Fulmali, A. O.; Kattaguri, R.; Dutta, K.; Prusty, R. K.; Ray, B. C.

    2018-03-01

    Fiber reinforced polymeric (FRP) composite materials are exposed to diverse changing environmental temperatures during their in-service period. Current investigation is aimed to investigate the influence of thermal-shock exposure on the mechanical behavior of multiwalled carbon nanotube (MWCNT) enhanced glass fiber reinforced polymeric (GFRP) composites. The samples were exposed to +70°C for 36 hrs followed by further exposure to ‑ 60°C for the similar interval of time. Tensile tests were conducted in order to evaluate the results of thermal-shock on the mechanical behavior of the neat and conditioned samples at 1 mm/min loading rate. The polymer phase i.e. epoxy was modified with various MWCNT content. The ultimate tensile strength (UTS) was raised by 15.11 % with increase in the 0.1 % MWCNT content GFRP as related to the thermal-shocked neat GFRP conditioned samples. The possible reason may be attributed to the variation in the coefficients of thermal expansion at the time of conditioning. Also, upto some extent the pre-existing residual stresses allows uniform distribution of stress and hence the reason in enhanced mechanical properties of GFRP and MWCNT filled composites. In order to access the modifications in the glass transition temperature (Tg) due to the addition of MWCNT in GFRP composite and also due to the thermal shock temperature modulated differential scanning calorimeter (TMDSC) measurements are carried out. Scanning electron microscopy(SEM) was carried out to identify different modes of failures and strengthening morphology in the composites.

  13. Evaluation of Shear Tie Connectors for Use in Insulated Concrete Sandwich Panels

    Science.gov (United States)

    2009-12-01

    stainless steel, galvanized carbon steel, carbon fiber reinforced polymers (CFRP), glass fiber reinforced polymer (GFRP), and basalt fiber reinforced polymer...Glass Fiber Reinforced Polymer (GFRP) Delta Tie produced by Dayton Superior; • (B) THERMOMASS® composite GFRP pins; • (C) THERMOMASS® non-composite...GFRP pins; • (D) Altus Group CFRP Grid; • (E) Universal Building products GFRP Teplo Tie; and • (F) Universal Building products Basalt FRP

  14. Effect of Different Bar Embedment Length on Bond-Slip in Plain and Fiber Reinforced Concrete

    NARCIS (Netherlands)

    Jankovic, D.; Chopra, M.B.; Kunnath, S.K.

    2001-01-01

    This research aims to study the behaviour of the concrete-steel bond using numerical models, taking into account the effect of the different bar embedment length. Both plain and fiber reinforced concrete (FRC) are modeled. The interface bond stress as well as load-displacement response of the

  15. Finite element modeling of reinforced concrete beams with a hybrid combination of steel and aramid reinforcement

    International Nuclear Information System (INIS)

    Hawileh, R.A.

    2015-01-01

    Highlights: • Modeling of concrete beams reinforced steel and FRP bars. • Developed finite element models achieved good results. • The models are validated via comparison with experimental results. • Parametric studies are performed. - Abstract: Corrosion of steel bars has an adverse effect on the life-span of reinforced concrete (RC) members and is usually associated with crack development in RC beams. Fiber reinforced polymer (FRP) bars have been recently used to reinforce concrete members in flexure due to their high tensile strength and superior corrosion resistance properties. However, FRP materials are brittle in nature, thus RC beams reinforced with such materials would exhibit a less ductile behavior when compared to similar members reinforced with conventional steel reinforcement. Recently, researchers investigated the performance of concrete beams reinforced with a hybrid combination of steel and Aramid Fiber Reinforced Polymer (AFRP) reinforcement to maintain a reasonable level of ductility in such members. The function of the AFRP bars is to increase the load-carrying capacity, while the function of the steel bars is to ensure ductility of the flexural member upon yielding in tension. This paper presents a three-dimensional (3D) finite element (FE) model that predicted the load versus mid-span deflection response of tested RC beams conducted by other researchers with a hybrid combination of steel and AFRP bars. The developed FE models account for the constituent material nonlinearities and bond–slip behavior between the reinforcing bars and adjacent concrete surfaces. It was concluded that the developed models can accurately capture the behavior and predicts the load-carrying capacity of such RC members. In addition, a parametric study is conducted using the validated models to investigate the effect of AFRP bar size, FRP material type, bond–slip action, and concrete compressive strength on the performance of concrete beams when reinforced

  16. Plasma Surface Modification of Glass-Fibre-Reinforced Polyester Enhanced by Ultrasonic Irradiation

    DEFF Research Database (Denmark)

    Kusano, Yukihiro; Singh, Shailendra Vikram; Bardenshtein, Alexander

    2010-01-01

    treatment can be highly enhanced by simultaneous high-power ultrasonic irradiation of the treating surface, because the delivered acoustic energy can reduce the thickness of the boundary gas layer. Here surfaces of glass-fibre-reinforced polyester (GFRP) plates were treated using an atmospheric pressure...

  17. Mechanical interaction between concrete and structural reinforcement in the tension stiffening process

    DEFF Research Database (Denmark)

    Lárusson, Lárus Helgi; Fischer, Gregor; Jönsson, Jeppe

    2011-01-01

    as Engineered Cementitious Composite (ECC), have been combined with steel and glass fiber reinforced polymer (GFRP) reinforcement to contrast the effects of brittle and ductile cement matrices as well as elastic/plastic and elastic reinforcement on the tension stiffening process. Particular focus...... investigated using an image-based deformation measurement and analysis system. This allowed for detailed view of surface deformations and the implications on the resulting response of the member in tension. In this study, conventional concrete and a ductile, strain hardening cement composite, known...

  18. Investigation on Mechanical Properties of Graphene Oxide reinforced GFRP

    Science.gov (United States)

    Arun, G. K.; Sreenivas, Nikhil; Brahma Reddy, Kesari; Sai Krishna Reddy, K.; Shashi Kumar, M. E.; Pramod, R.

    2018-02-01

    Graphene and E-glass fibres individually find a very wide field of applications because of their various mechanical and chemical properties. Recently graphene has attracted both academic and industrial interest because it can produce a dramatic improvement in properties at very low filler content. The primary interest of this venture is to investigate on Graphene reinforced polymer matrix nanocomposites and finding the mechanical properties. The composites were fabricated by Hand Lay Process and have been evaluated by the addition of Graphene with 1, 1.5, 2, 2.5 and 3 by weight% as reinforcement in composites. The theoretical and experimental results validate the increase in properties such as tensile strength, hardness and flexural strength with increase in weight proportions from 1% to 3% of graphene powder. It was observed that the composite material with 2.5% weight fraction of graphene yielded superior properties over other weight percentages. Graphene reinforced polymer matrix nanocomposites finds its major applications in the manufacture of aircraft bodies, ballistic missiles, sporting equipment, marine applications and extraterrestrial ventures.

  19. Bond-Slip Behavior of Basalt Fiber Reinforced Polymer Bar in Concrete Subjected to Simulated Marine Environment: Effects of BFRP Bar Size, Corrosion Age, and Concrete Strength

    Directory of Open Access Journals (Sweden)

    Yongmin Yang

    2017-01-01

    Full Text Available Basalt Fiber Reinforced Polymer (BFRP bars have bright potential application in concrete structures subjected to marine environment due to their superior corrosion resistance. Available literatures mainly focused on the mechanical properties of BFRP concrete structures, while the bond-slip behavior of BFRP bars, which is a key factor influencing the safety and service life of ocean concrete structures, has not been clarified yet. In this paper, effects of BFRP bars size, corrosion age, and concrete strength on the bond-slip behavior of BFRP bars in concrete cured in artificial seawater were investigated, and then an improved Bertero, Popov, and Eligehausen (BPE model was employed to describe the bond-slip behavior of BFRP bars in concrete. The results indicated that the maximum bond stress and corresponding slip decreased gradually with the increase of corrosion age and size of BFRP bars, and ultimate slip also decreased sharply. The ascending segment of bond-slip curve tends to be more rigid and the descending segment tends to be softer after corrosion. A horizontal end in bond-slip curve indicates that the friction between BFRP bars and concrete decreased sharply.

  20. PERBAIKAN KEKUATAN DAN DAKTILITAS KOLOM BETON BERTULANG YANG MENDAPAT BEBAN GEMPA MENGGUNAKAN GLASS FIBER REINFORCED POLYMER

    Directory of Open Access Journals (Sweden)

    Parmo Parmo

    2014-05-01

    Full Text Available Repairing the Strength and Ductility of Reinforced Concrete Column That Got Earthquake using Gla­ss Fiber Reinforced Polymer. This study aims to identify the additional strength and ductility of reinforced concrete columns af­ter being re­­­­tro­fitted using glass fiber reinforced polymer (GFRP and got the brunt of the earth­quake. This study uses two objects tested columns, which are being tested for three times. Each column size is 350 x 350 x 1100 mm with f'c = 20.34 MPa and fy = 549.94 MPa. The tes­t­ing is performed by giving a constant axial load of 748 kN and cyclic lateral load using con­trol displacement method in order to simulate the brunt of earth­quake. The results show an in­crea­se in lateral capacity of co­lumn by 43.96%. Re­tro­­fitting the column with GFRP has a duc­tile property, which is shown by the increase of the displacement ductility by 129.14% and curvature ductility by 118.27%.   Penelitian ini ber­tujuan untuk mengetahui penambahan kekuatan dan dak­ti­li­­­­tas kolom beton bertulang se­telah diretrofit menggunakan glass fiber reinforced po­ly­­­mer (GFRP dan mendapat be­ban gempa. Penelitian ini menggunakan benda ­uji dua buah kolom dengan tiga kali pengujian. Masing-masing ukuran kolom 350 x 350 x 1100 mm dengan f’c = 20,34 MPa dan fy = 549,94 MPa. Pengujian dilakukan de­ngan memberikan beban ak­sial konstan 748 kN dan beban lateral siklik yang meng­gu­nakan metode di­splacemet con­trol untuk mensimulasikan beban gempa. Hasil pe­ne­­­litian menunjukkan pe­ningkatan kapasitas lateral pada kolom sebesar 43,96%. Retrofit kolom dengan GFRP bersifat dak­tail yang ditunjukkan dengan meningkatnya daktilitas per­pindahan sebesar 129,14% dan dak­­­tilitas kurvatur se­besar 118,27%.

  1. Effect of corrosion and sandblasting on the high cycle fatigue behavior of reinforcing B500C steel bars

    Directory of Open Access Journals (Sweden)

    Marina C. Vasco

    2017-10-01

    Full Text Available In a series of applications, steel reinforced concrete structures are subjected to fatigue loads during their service life, what in most cases happens in corrosive environments. Surface treatments have been proved to represent proper processes in order to improve both fatigue and corrosion resistances. In this work, the effect of corrosion and sandblasting on the high cycle fatigue behavior reinforcing steel bars is investigated. The investigated material is the reinforcing steel bar of technical class B500C, of nominal diameter of 12 mm. Steel bars specimens were first exposed to corrosion in alternate salt spray environment for 30 and 60 days and subjected to both tensile and fatigue tests. Then, a series of specimens were subjected to common sandblasting, corroded and mechanically tested. Metallographic investigation and corrosion damage evaluation regarding mass loss and martensitic area reduction were performed. Tensile tests were conducted after each corrosion exposure period prior to the fatigue tests. Fatigue tests were performed at a stress ratio, R, of 0.1 and loading frequency of 20 Hz. All fatigue tests series as well as tensile test were also performed for as received steel bars to obtain the reference behavior. The results have shown that sandblasting hardly affects the tensile behavior of the uncorroded material. The effect of sandblasting on the tensile behavior of pre-corroded specimens seems to be also limited. On the other hand, fatigue results indicate an improved fatigue behavior for the sandblasted material after 60 days of corrosion exposure. Martensitic area reductions, mass loss and depth of the pits were significantly smaller for the case of sandblasted materials, which confirms an increased corrosion resistance

  2. Ultrasound enhanced plasma treatment of glass-fibre-reinforced polyester in atmospheric pressure air for adhesion improvement

    DEFF Research Database (Denmark)

    Kusano, Yukihiro; Singh, Shailendra Vikram; Norrman, Kion

    2011-01-01

    A glass-fibre-reinforced polyester (GFRP) plate was treated with dielectric barrier discharge (DBD) at atmospheric pressure in air for adhesion improvement. The effects of ultrasonic irradiation using a high-power gas-jet generator during the treatment were investigated. The optical emission...... damage of the GFRP plates. The polar component of the surface energy of the polyester plate was 21 mJ/m2 before the treatment, increased markedly to 52 mJ/m2 after 2-s plasma treatment without ultrasonic irradiation, and further increased slightly after longer treatments. In addition, the polar component...

  3. Criterion for matrix cracking in glass fiber reinforced cross-ply laminates. GFRP chokko sekisoban ni okeru matrix kiretsu no hattatsu kijun

    Energy Technology Data Exchange (ETDEWEB)

    Motoki, S.; Fukuda, T. (Osaka City Univ., Osaka (Japan). Faculty of Engineering); Tanaka, M. (Kobe City College of Technology, Kobe (Japan))

    1992-05-15

    In this research, with regard to GFRP cross-ply laminates, which were the most basic lamination composition, the factors governing the progress of matrix cracks at the 90{degree} layer were studied, in particular the criterion for not depending on the thickness of the 90{degree} layer was examined. For the experiment concerning the above, GFRP prepreg was laminated and three kinds of cross-ply laminates were made for use. A quasistatic tensile load was applied to these specimens and a load-displacement curve was measured, and at the same time, the matrix crack numbers generated in the 90{degree} layer were counted. As a result, it was found that the maximum value of the vertical stress in the loading direction of 90{degree} layer did not depend on the lamination composition, hence could become the criterion for the crack progress. Also it was found that in case when this stress surpassed a certain threshold value, cracks were formed, but in case when it was smaller than the threshold value, no crack was formed. 12 refs., 14 figs.

  4. Wear and friction behaviour of soft particles filled random direction short GFRP composites

    International Nuclear Information System (INIS)

    Srivastava, V.K.; Wahne, S.

    2007-01-01

    The random direction short E-glass fibre reinforced epoxy resin composites filled with the particles of mica and tricalcium phosphate (TCP) were prepared by hand lay-up method. The wear and friction behaviour of random direction short E-glass fibre reinforced epoxy resin (GFRP) composites sliding against AISI-1045 steel in a pin-on-disc configuration were evaluated on a TR-20LE wear and friction tester. The microhardness, density, tensile strength and compressive strength of the filled and unfilled mica as well as TCP particles were determined. The morphology of the worn surfaces of the unfilled and filled random E-glass fibre composites and the transfer films were analyzed with the scanning electron microscope. It was found that the particles as the fillers contributed significantly to improve the mechanical properties and wear resistance of the E-glass fibre. This was because the particulates as the fillers contributed to enhance the bonding strength between the fibre and the epoxy resin. Moreover, the wear and friction properties of the random E-glass fibre composites were reduced by increasing filler weight of particles

  5. Gliding arc surface treatment of glass-fiber-reinforced polyester enhanced by ultrasonic irradiation

    DEFF Research Database (Denmark)

    Kusano, Yukihiro; Norrman, Kion; Drews, Joanna Maria

    2011-01-01

    . The efficiency of such a plasma treatment at atmospheric pressure can be further improved by ultrasonic irradiation onto the surface during the treatment. In the present work glass fiber reinforced polyester (GFRP) plates are treated using an atmospheric pressure gliding arc with and without ultrasonic...

  6. Application of Gurson–Tvergaard–Needleman Constitutive Model to the Tensile Behavior of Reinforcing Bars with Corrosion Pits

    Science.gov (United States)

    Xu, Yidong; Qian, Chunxiang

    2013-01-01

    Based on meso-damage mechanics and finite element analysis, the aim of this paper is to describe the feasibility of the Gurson–Tvergaard–Needleman (GTN) constitutive model in describing the tensile behavior of corroded reinforcing bars. The orthogonal test results showed that different fracture pattern and the related damage evolution process can be simulated by choosing different material parameters of GTN constitutive model. Compared with failure parameters, the two constitutive parameters are significant factors affecting the tensile strength. Both the nominal yield and ultimate tensile strength decrease markedly with the increase of constitutive parameters. Combining with the latest data and trial-and-error method, the suitable material parameters of GTN constitutive model were adopted to simulate the tensile behavior of corroded reinforcing bars in concrete under carbonation environment attack. The numerical predictions can not only agree very well with experimental measurements, but also simplify the finite element modeling process. PMID:23342140

  7. Mechanical properties of GFRP tube confined recycled concrete under axial compression

    International Nuclear Information System (INIS)

    Wang, Xiaogang; Liang, Chaofeng; Zhou, Zechenglong; Dong, Lanqi; Ding, Kewei; Huang, Jialun

    2015-01-01

    This article outlines the recycled aggregate replacement rate and thick-diameter rate of GFRP tube confined in recycled concrete, which has an important impact on the material's compressive strength. Overall, under the same conditions of using recycled concrete, the bearing capacity of short concrete columns can be improved by using broader GFRP tubes. There is a four-fold increase in the bearing capacity of short concrete columns compared to the short column without the restriction of a GFRP tube. The bearing capacity of a short column crafted by recycled coarse aggregate is much lower (about 30%). than those made by common concrete column Additionally, the bearing capacity of short columns made by recycled fine aggregates is also lower than those made by common concrete (approximately 20%). Finally, we find that there is no significant difference between experimental and theoretical data. (paper)

  8. 75 FR 47260 - Certain Steel Concrete Reinforcing Bars from Turkey: Notice of Amended Final Results Pursuant to...

    Science.gov (United States)

    2010-08-05

    ... concrete reinforcing bars (rebar) from Turkey. See Nucor Corporation, Gerdau Ameristeel, Inc., and... calculated for Ekinciler to the Department. See Nucor Corporation, Gerdau Ameristeel Corporation, and Commercial Metals Company v. United States, Court No. 07-00457 (Apr. 14, 2009) (Nucor). On May 14, 2009, the...

  9. Static, Fire and Fatigue Tests of Ultra High-Strength Fibre Reinforced Concrete and Ribbed Bars

    DEFF Research Database (Denmark)

    Hansen, Lars Pilegaard; Heshe, Gert

    2001-01-01

    A new building system has been developed during the last 10 years. This new system consists of a column / slab system with 6 x 6 m distance between the columns. The slabs are precast concrete elements of size 2.9 x 5.9 m connected through joints of ultra high strength fibre reinforced concrete...... - Densit Joint Cast ®. Also the connections between the columns and the slabs are made of this very strong concrete material. The paper describes some of the static tests carried out as well as some fire tests. Further, 2 chapters deal with some fatigue tests of the reinforcing bars as well as some fatigue...

  10. Enhancing corrosion resistance of reinforced concrete structures with hybrid fiber reinforced concrete

    International Nuclear Information System (INIS)

    Blunt, J.; Jen, G.; Ostertag, C.P.

    2015-01-01

    Highlights: • Reinforced concrete beams were subjected to cyclic flexural loading. • Hybrid fiber reinforced composites were effective in reducing corrosion rates. • Crack resistance due to fibers increased corrosion resistance of steel rebar. • Galvanic corrosion measurements underestimated corrosion rates. • Polarization resistance measurements predicted mass loss more accurately. - Abstract: Service loads well below the yield strength of steel reinforcing bars lead to cracking of reinforced concrete. This paper investigates whether the crack resistance of Hybrid Fiber Reinforced Concrete (HyFRC) reduces the corrosion rate of steel reinforcing bars in concrete after cyclic flexural loading. The reinforcing bars were extracted to examine their surface for corrosion and compare microcell and macrocell corrosion mass loss estimates against direct gravimetric measurements. A delay in corrosion initiation and lower active corrosion rates were observed in the HyFRC beam specimens when compared to reinforced specimens containing plain concrete matrices cycled at the same flexural load

  11. Experimental Investigation of a Self-Sensing Hybrid GFRP-Concrete Bridge Superstructure with Embedded FBG Sensors

    OpenAIRE

    Wang, Yanlei; Li, Yunyu; Ran, Jianghua; Cao, Mingmin

    2012-01-01

    A self-sensing hybrid GFRP-concrete bridge superstructure, which consists of two bridge decks and each bridge deck is comprised of four GFRP box sections combined with a thin layer of concrete in the compression zone, was developed by using eight embedded FBG sensors in the top and bottom flanges of the four GFRP box sections at midspan section of one bridge deck along longitudinal direction, respectively. The proposed self-sensing hybrid bridge superstructure was tested in 4-point loading to...

  12. Push-out tests and evaluation of FRP perfobond rib shear connectors performance

    Science.gov (United States)

    Kolpasky, Ludvik; Ryjacek, Pavel

    2017-09-01

    The behavioural characteristics of FRP (fibre-reinforced polymer) perfobond rib shear connector was examined through push-out tests in order to verify the applicability for pedestrian bridge structure. The aim of this study is to determine interaction between high performance concrete slab and handmade FRP plate which represent web of the composite beam. Combination of these modern materials leads to structural system with both great load bearing capacity and also sufficient flexural stiffness of the composite element. Openings cut into the GFRP plate at a variable spacing allow GFRP reinforcement bars to be inserted to act as shear studs. Hand lay-up process can increase suitable properties of FRP for connection by perfobond rib shear connectors. In this study, three push-out tests on fiber-reinforced polymer were performed to investigate their shear behaviour. The results of the push-out tests on FRP perfobond rib shear connector indicates great promise for application in full scale structures.

  13. Bond characteristics of steel fiber and deformed reinforcing steel bar embedded in steel fiber reinforced self-compacting concrete (SFRSCC)

    Science.gov (United States)

    Aslani, Farhad; Nejadi, Shami

    2012-09-01

    , information is hardly available in this area. In this study, bond characteristics of deformed reinforcing steel bars embedded in SFRSCC is investigated secondly.

  14. A comparison of tensile, fracture and fatigue mechanical behaviour of structural reinforcing bars made with different steels

    Directory of Open Access Journals (Sweden)

    Rodríguez, C.

    2013-09-01

    Full Text Available The use of austenitic stainless steels as rebar is an option increasingly used in reinforced concrete structures exposed to aggressive environments and especially those that have to work in marine environments. The same is true for duplex stainless steel rebars, although nowadays they have a lower use, mainly due to the fact that their inclusion in the reinforced concrete standards was delayed 10 years compared to austenitic stainless steel ones, and consequently their in-service behavior is not as well known. A study of the mechanical properties, including fracture toughness, fatigue behaviour and corrosion resistance in saline alkaline environments of austenitic (AISI 304LN and 316LN and duplex (D2205 stainless steel reinforcing bars was performed in this work. Bars made on a high ductility carbon steel (B500SD that are normally used to reinforce concrete were also characterized and used as a comparison. Stainless steel reinforcing bars show mechanical properties at least similar but usually higher than one of the best carbon steel re-bars (B500SD, along with a significantly higher ductility and, of course, much better corrosion behaviour in saline alkaline environments.El uso de aceros inoxidables austeníticos como armaduras de refuerzo es una opción cada vez más utilizada en estructuras de hormigón armado expuestas a ambientes agresivos y especialmente en las que han de trabajar en ambientes marinos. Lo mismo cabe decir de las armaduras de acero inoxidable dúplex, si bien su uso es menor, debido sobre todo a que su inclusión en la normativa aplicable al armado de hormigón se retrasó 10 años con respecto a los inoxidables austeníticos y, consecuentemente, su comportamiento en servicio es menos conocido. En este trabajo se analiza el comportamiento mecánico, incluyendo fractura y fatiga, así como la resistencia a la corrosión en medios que simulan un hormigón contaminado de cloruros, de armaduras fabricadas tanto con

  15. Study on mechanical properties of fly ash impregnated glass fiber reinforced polymer composites using mixture design analysis

    International Nuclear Information System (INIS)

    Satheesh Raja, R.; Manisekar, K.; Manikandan, V.

    2014-01-01

    Highlights: • FRP with and without fly ash filler were prepared. • Mechanical properties of composites were analyzed. • Mixture Design Method was used to model the system. • Experimental and mathematical model results were compared. - Abstract: This paper describes the mechanical behavior of fly ash impregnated E-glass fiber reinforced polymer composite (GFRP). Initially the proportion of fiber and resin were optimized from the analysis of the mechanical properties of the GFRP. It is observed that the 30 wt% of E-glass in the GFRP without filler material yields better results. Then, based on the optimized value of resin content, the varying percentage of E-glass and fly ash was added to fabricate the hybrid composites. Results obtained in this study were mathematically evaluated using Mixture Design Method. Predictions show that 10 wt% addition of fly ash with fiber improves the mechanical properties of the composites. The fly ash impregnated GFRP yields significant improvement in mechanical strength compared to the GFRP without filler material. The surface morphologies of the fractured specimens were characterized using Scanning Electron Microscope (SEM). The chemical composition and surface morphology of the fly ash is analyzed by using Energy Dispersive Spectroscopy (EDS) and Scanning Electron Microscope

  16. Temperature dependency of tensile properties of GFRP composite for wind turbine blades

    Energy Technology Data Exchange (ETDEWEB)

    Huh, Yong Hak; Kim, Jong Il; Kim, Dong Jin; Lee, Gun Chang [Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2012-09-15

    In this study, the temperature dependency of the tensile properties of a glass fiber reinforced plastic (GFRP) used in wind turbine blades was examined. The tensile strength, elastic modulus, and Poisson's ratio of the tensile specimen manufactured from uniaxial (0 .deg.) and triaxial (0/{+-}45.deg) laminate composite plates were measured at four different testing temperatures-room temperature, -30 .deg. C, -50 .deg. C, and 60 .deg. C. It was found that the tensile strengths and elastic moduli of the uniaxial laminates were greater than those of the triaxial laminates over the testing temperature range. The tensile strength of the two laminates was significantly dependent on the testing temperature, while the dependency of the elastic modulus on the temperature was insignificant. Furthermore, it could be considered that the Poisson's ratio changed slightly with a change in the testing temperature.

  17. Temperature dependency of tensile properties of GFRP composite for wind turbine blades

    International Nuclear Information System (INIS)

    Huh, Yong Hak; Kim, Jong Il; Kim, Dong Jin; Lee, Gun Chang

    2012-01-01

    In this study, the temperature dependency of the tensile properties of a glass fiber reinforced plastic (GFRP) used in wind turbine blades was examined. The tensile strength, elastic modulus, and Poisson's ratio of the tensile specimen manufactured from uniaxial (0 .deg.) and triaxial (0/±45.deg) laminate composite plates were measured at four different testing temperatures-room temperature, -30 .deg. C, -50 .deg. C, and 60 .deg. C. It was found that the tensile strengths and elastic moduli of the uniaxial laminates were greater than those of the triaxial laminates over the testing temperature range. The tensile strength of the two laminates was significantly dependent on the testing temperature, while the dependency of the elastic modulus on the temperature was insignificant. Furthermore, it could be considered that the Poisson's ratio changed slightly with a change in the testing temperature

  18. Ultrasound enhanced 50 Hz plasma treatment of glass-fiber-reinforced polyester at atmospheric pressure

    DEFF Research Database (Denmark)

    Kusano, Yukihiro; Norrman, Kion; Singh, Shailendra Vikram

    2013-01-01

    Glass-fiber-reinforced polyester (GFRP) plates are treated using a 50Hz dielectric barrier discharge at a peak-to-peak voltage of 30 kV in helium at atmospheric pressure with and without ultrasonic irradiation to study adhesion improvement. The ultrasonic waves at the fundamental frequency...

  19. Experimental studies on multicellular GFRP bridge deck panels ...

    Indian Academy of Sciences (India)

    M P MUTHURAJ

    2017-11-20

    Nov 20, 2017 ... design of a new bridge deck panel made of GFRP. .... cient manufacturing processes with minimal wastage. But re-use of the remaining FRP elements during manufacture ... Energy consumption for production of different.

  20. Degradation of glass-fiber reinforced plastics by low temperature irradiation

    International Nuclear Information System (INIS)

    Nishijima, S.; Nishiura, T.; Ueno, S.; Tsukazaki, Y.; Okada, T.; Okada, T.M.; Miyata, K.; Kodaka, H.

    1998-01-01

    Low-temperature irradiation effects of glass-fiber reinforced plastics (GFRP) have been investigated in terms of mechanical properties such as interlaminar shear strength and creep, in order to obtain the selection standard of insulating materials of superconducting magnets used for fusion reactor. It was revealed that the degradation of interlaminar shear strength was strongly dependent of characteristics of matrix and/or glass/epoxy interface. Especially, the research has been carried out towards the creep behaviour of epoxy which is the matrix of GFRP, by both experimental and simulation method. It was suggested that the synergistic effects was observed in creep test. From the molecular dynamics simulation it was found that the cage effects was the one of the main reason of the stress effects of creep behavior under irradiation. (author)

  1. Prestressing Effects on the Performance of Concrete Beams with Near-surface-mounted Carbon-fiber-reinforced Polymer Bars

    Science.gov (United States)

    Hong, Sungnam; Park, Sun-Kyu

    2016-07-01

    The effects of various prestressing levels on the flexural behavior of concrete beams strengthened with prestressed near-surface-mounted (NSM) carbon-fiber-reinforced polymer (CFRP) bars were investigated in this study. Four-point flexural tests up to failure were performed using a total of six strengthened prestressed and nonprestressed concrete beams. The nonprestressed strengthened beam failed by premature debonding at the interface of concrete and the epoxy adhesive, but the prestressed one failed owing due to rupture of the CFRP bar. As the prestressing level of the CFRP bar increased, the cracking and yield loads of the prestressed beams increased, but its effect on their deflections was insignificant. The ultimate load was constant regardless of prestressing level, but the ultimate deflection was almost inversely proportional to the level.

  2. The Reduction of CO2 Emissions by Application of High-Strength Reinforcing Bars to Three Different Structural Systems in South Korea

    Directory of Open Access Journals (Sweden)

    Seungho Cho

    2017-09-01

    Full Text Available The architecture, engineering, and construction (AEC industry consume approximately 23% of the national energy annually, and are considered among the highest energy consuming industries. Recently, several studies have focused on establishing strategies to reduce the emissions of carbon dioxide in the AEC industry by utilisation of low-carbon materials, material reuse, recycling and minimal usage; selection of an optimal structural system and structural optimisation; and optimisation of construction operations. While several studies examined material selection and replacement in concrete, there is a paucity of studies investigating the replacement and implementation of high-strength re-bars to lower the carbon dioxide emissions in buildings. To fill this research gap, the purpose of this study involves calculating the emissions of carbon dioxide by applying high-strength reinforcement bars in three different types of buildings. The input–output analysis method was adopted to compute the emissions of carbon dioxide by using the yield strength and size. This study showed that the application of the high-strength re-bars is beneficial in reducing the input amount of materials, although the quantity of reinforcing bars on the development and splice increased. Furthermore, the application of high-strength deformed bars is also advantageous as a means of carbon dioxide reduction in the studied structural systems. In this study, the CO2 emissions of three different structural systems indicated that implementing SD500 re-bars is the most effective method to reduce carbon dioxide emissions.

  3. 75 FR 7562 - Certain Steel Concrete Reinforcing Bars From Turkey: Notice of Court Decision Not in Harmony With...

    Science.gov (United States)

    2010-02-22

    ... Reinforcing Bars From Turkey: Notice of Court Decision Not in Harmony With Final Results of Administrative...: On January 19, 2010, the United States Court of International Trade (CIT) sustained the Department of... Corporation, Gerdau Ameristeel Corporation, and Commercial Metals Company v. United States and Icdas Celik...

  4. Development of high radiation-resistant glass fiber reinforced plastics with cyanate-based resin for superconducting magnet systems

    Energy Technology Data Exchange (ETDEWEB)

    Idesaki, Akira, E-mail: idesaki.akira@qst.go.jp [Quantum Beam Science Directorate, Japan Atomic Energy Agency, Watanuki 1233, Takasaki, Gunma 370-1292 (Japan); Nakamoto, Tatsushi [Cryogenic Science Center, High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Yoshida, Makoto [Institute of Particle and Nuclear Studies, High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Shimada, Akihiko [Quantum Beam Science Directorate, Japan Atomic Energy Agency, Watanuki 1233, Takasaki, Gunma 370-1292 (Japan); Iio, Masami; Sasaki, Kenichi; Sugano, Michinaka [Cryogenic Science Center, High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Makida, Yasuhiro [Institute of Particle and Nuclear Studies, High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Ogitsu, Toru [Cryogenic Science Center, High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan)

    2016-11-15

    Highlights: • GFRPs for superconducting magnet systems were developed. • Cyanate-based resins were used for GFRPs as matrices. • Radiation resistance was evaluated based on gas evolution and mechanical properties. • GFRP with bismaleimide-triazine resin exhibited excellent radiation resistance. - Abstract: Glass fiber reinforced plastics (GFRPs) with cyanate ester resin/epoxy resin, bismaleimide resin/epoxy resin, and bismaleimide-triazine resin as matrices were developed for the superconducting magnet systems used in high intensity accelerators. The radiation resistance of these GFRPs was evaluated based on their gas evolution and changes in their mechanical properties after gamma-ray irradiation with dose of 100 MGy in vacuum at ambient temperature. After irradiation, a small amount of gas was evolved from all of the GFRPs, and a slight decrease in mechanical properties was observed compared with the conventional epoxy resin-GFRP, G10. Among the GFRPs, the smallest amount of gas (6 × 10{sup −5} mol/g) was evolved from the GFRP with the bismaleimide-triazine resin, which also retained more than 88% of its flexural strength after 100 MGy irradiation; this GFRP is thus considered the most promising material for superconducting magnet systems.

  5. 50-Hz plasma treatment of glass fibre reinforced polyester at atmospheric pressure enhanced by ultrasonic irradiation

    DEFF Research Database (Denmark)

    Kusano, Yukihiro; Norrman, Kion; Singh, Shailendra Vikram

    2011-01-01

    Glass fibre reinforced polyester (GFRP) plates are treated using a 50-Hz dielectric barrier discharge at peak-to-peak voltage of 30 kV in helium at atmospheric pressure with and without ultrasonic irradiation to study adhesion improvement. The ultrasonic waves at the fundamental frequency of around...

  6. The anchorage capacity of reinforcing bars at normal and high temperatures

    DEFF Research Database (Denmark)

    Hertz, Kristian Dahl

    1982-01-01

    of the cross-section. A simple method for calculating the resistance to splitting is proposed, and a test method for determining the bond strength is presented. Test results are shown from a series of 280 specimens exposed to various maximum temperatures, and a relation between the bond strength......The anchorage failure of reinforcing bars is analysed, and it is shown that two modes of failures are possible: splitting or bond failure. It is concluded that the anchorage capacity cannot be estimated by means of a standard specimen, since splitting failure is dependent upon the geometry...... and the ultimate limit stress of concrete under plane strain conditions is indicated. The influence of high temperatures upon the anchorage resistance is explained, and the theory is illustrated by examples....

  7. Impact properties of aluminium - glass fiber reinforced plastics sandwich panels

    Directory of Open Access Journals (Sweden)

    Mathivanan Periasamy

    2012-06-01

    Full Text Available Aluminium - glass fiber reinforced plastics (GFRP sandwich panels are hybrid laminates consisting of GFRP bonded with thin aluminum sheets on either side. Such sandwich materials are increasingly used in airplane and automobile structures. Laminates with varying aluminium thickness fractions, fiber volume fractions and orientation in the layers of GFRP were fabricated by hand lay up method and evaluated for their impact performance by conducting drop weight tests under low velocity impacts. The impact energy required for initiating a crack in the outer aluminium layer as well as the energy required for perforation was recorded. The impact load-time history was also recorded to understand the failure behavior. The damage depth and the damage area were measured to evaluate the impact resistance. Optical photography and scanning electron micrographs were taken to visualize the crack and the damage zone. The bidirectional cross-ply hybrid laminate (CPHL has been found to exhibit better impact performance and damage resistance than the unidirectional hybrid laminate (UDHL. Increase in aluminium thickness fraction (Al tf and fiber volume fraction (Vf resulted in an increase in the impact energy required for cracking and perforation. On an overall basis, the sandwich panels exhibited better impact performance than the monolithic aluminium.

  8. An Investigation of Bond Strength of Reinforcing Bars in Fly Ash and GGBS Based Geopolymer Concrete

    Directory of Open Access Journals (Sweden)

    Boopalan C.

    2017-01-01

    Full Text Available Geopolymers are amorphous aluminosilicate materials. Geopolymers are binders formed by alkali activation of Geopolymer Source Materials (GSM using an alkaline activator solution. Concretes made using Geopolymer binders are excellent alternative to the Ordinary Portland Cement concretes from strength, durability, and ecological considerations. Especially, usage of industrial waste materials such as Fly Ash and Slags as GSMs considerably lower the carbon footprint of concrete and mitigate the damage due to the unscientific dumping/disposal of these materials. To use the Geopolymer concrete (GPC for reinforced structural members, the composite action of reinforcing bars with Geopolymer concrete i.e. the bond behaviour should be well understood. This paper describes the bond behaviour of 12mm and 16mm dia. bars embedded in Fly ash and GGBS based Geopolymer concrete and conventional Portland Pozzolana cement concrete specimens investigated using the pull-out tests as per Indian Standard Code IS:2770(Part-I; the bond stresses and corresponding slips were found out. The bond stress increased with increase in compressive strength. The peak bond stress was found to be 4.3 times more than the design bond stress as per IS:456-2000. The Geopolymer concretes possess higher bond strength compared to the conventional cement concretes.

  9. Self-sensing CF-GFRP rods as mechanical reinforcement and sensors of concrete beams

    Science.gov (United States)

    Nanni, F.; Auricchio, F.; Sarchi, F.; Forte, G.; Gusmano, G.

    2006-02-01

    In this paper testing carried out on concrete beams reinforced with self-sensing composite rods is presented. Such concrete beams, whose peculiarity is to be reinforced by self-sensing materials able to generate an alarm signal when fixed loads are reached, were designed, manufactured and tested. The reinforcing rods were manufactured by pultrusion and consisted of self-sensing hybrid composites containing both glass and carbon fibres in an epoxy resin. The experimentation was carried out by performing simultaneously mechanical tests on the reinforced beams and electrical measurements on the composite rods. The results showed that the developed system reached the target proposed, giving an alarm signal.

  10. ASSIMILATION OF PRODUCTION OF THERMO-MECHANICALLY HARDENED REINFORCING BAR WITH EFFECTIVE AND ECONOMICAL CUT, EQUIVALENT DIAMETER 5,5—8,0 mm and 500 H/mm2

    Directory of Open Access Journals (Sweden)

    V. A. Matochkin

    2005-01-01

    Full Text Available The carried out team-work of NIIZHB and RUP “BMZ” enabled to receive new technological decisions at production of bale reinforcing bar, realization of which will increase reliability of reinforced-concrete constructions of buildings and installations.

  11. Diagnostics of glass fiber reinforced polymers and comparative analysis of their fabrication techniques with the use of acoustic emission

    Science.gov (United States)

    Bashkov, O. V.; Bryansky, A. A.; Panin, S. V.; Zaikov, V. I.

    2016-11-01

    Strength properties of the glass fiber reinforced polymers (GFRP) fabricated by vacuum and vacuum autoclave molding techniques were analyzed. Measurements of porosity of the GFRP parts manufactured by various molding techniques were conducted with the help of optical microscopy. On the basis of experimental data obtained by means of acoustic emission hardware/software setup, the technique for running diagnostics and forecasting the bearing capacity of polymeric composite materials based on the result of three-point bending tests has been developed. The operation principle of the technique is underlined by the evaluation of the power function index change which takes place on the dependence of the total acoustic emission counts versus the loading stress.

  12. Influence of transverse reinforcement on perforation resistance of reinforced concrete slabs under hard missile impact

    International Nuclear Information System (INIS)

    Orbovic, Nebojsa; Sagals, Genadijs; Blahoianu, Andrei

    2015-01-01

    This paper describes the work conducted by the Canadian Nuclear Safety Commission (CNSC) related to the influence of transverse reinforcement on perforation capacity of reinforced concrete (RC) slabs under “hard” missile impact (impact with negligible missile deformations). The paper presents the results of three tests on reinforced concrete slabs conducted at VTT Technical Research Centre (Finland), along with the numerical simulations as well as a discussion of the current code provisions related to impactive loading. Transverse reinforcement is widely used for improving the shear and punching strength of concrete structures. However, the effect of this reinforcement on the perforation resistance under localized missile impact is still unclear. The goal of this paper is to fill the gap in the current literature related to this topic. Based on similar tests designed by the authors with missile velocity below perforation velocity, it was expected that transverse reinforcement would improve the perforation resistance. Three slabs were tested under almost identical conditions with the only difference being the transverse reinforcement. One slab was designed without transverse reinforcement, the second one with the transverse reinforcement in form of conventional stirrups with hooks and the third one with the transverse reinforcement in form of T-headed bars. Although the transverse reinforcement reduced the overall damage of the slabs (the rear face scabbing), the conclusion from the tests is that the transverse reinforcement does not have important influence on perforation capacity of concrete slabs under rigid missile impact. The slab with T-headed bars presented a slight improvement compared to the baseline specimen without transverse reinforcement. The slab with conventional stirrups presented slightly lower perforation capacity (higher residual missile velocity) than the slab without transverse reinforcement. In conclusion, the performed tests show slightly

  13. Degradation of Waterfront Reinforced Concrete Structures

    African Journals Online (AJOL)

    Key words: Degradation, reinforced concrete, Dar es Salaam port. Abstract—One of the ... especially corrosion of the reinforcement. ... Corrosion of steel reinforcement contributes .... cracks along the line of reinforcement bars and most of the ...

  14. Evaluate of the Effects of Drilling with Varying Spindle Speed Using Different Thickness of GFRP on the Damage Factor

    Directory of Open Access Journals (Sweden)

    Keong Woo Tze

    2014-07-01

    Full Text Available Composite have been widely used in industries which such as aircraft structural components, electric and electronics components, aerospace, and oil and gas fields due to their superior mechanical properties. Among machining process, drilling can be considered as one of the most important process in final machining of composite. In this research, vacuum assisted resin infusion method is use in fabricating the glass fiber reinforcement polymer samples, where different thickness of GFRP were used in the drilling process with different spindle speed. The results show that the temperature influences the damage factor of the drilling. Higher spindle speed will generate higher temperature that softens the matrix thus generating lower damage factor. The suitable drill bit temperature is between 150-200°C

  15. Strain Capacity of Reinforced Concrete Members Subjected to Uniaxial Tension

    DEFF Research Database (Denmark)

    Hagsten, Lars German; Rasmussen, Annette Beedholm; Fisker, Jakob

    2017-01-01

    The aim of this paper is to set up a method to determine the strain capacity of tension bars of reinforced concrete (RC) subjected to pure tension. Due to the interaction between reinforcement and concrete and due to the presence of cracks, the stresses in both reinforcement and concrete...... are varying along the length of the tension bar. The strain capacity of the tension bar is seen as the average strain in the reinforcement at the load level corresponding to the ultimate stress capacity of the reinforcement at the cracks. The result of the approach is in overall good agreement when comparing...

  16. Bar-spheroid interaction in galaxies

    Science.gov (United States)

    Hernquist, Lars; Weinberg, Martin D.

    1992-01-01

    N-body simulation and linear analysis is employed to investigate the secular evolution of barred galaxies, with emphasis on the interaction between bars and spheroidal components of galaxies. This interaction is argued to drive secular transfer of angular momentum from bars to spheroids, primarily through resonant coupling. A moderately strong bar, having mass within corotation about 0.3 times the enclosed spheroid mass, is predicted to shed all its angular momentum typically in less than about 10 exp 9 yr. Even shorter depletion time scales are found for relatively more massive bars. It is suggested either that spheroids around barred galaxies are structured so as to inhibit strong coupling with bars, or that bars can form by unknown processes long after disks are established. The present models reinforce the notion that bars can drive secular evolution in galaxies.

  17. Real time sensing of structural glass fiber reinforced composites by using embedded PVA - carbon nanotube fibers

    Directory of Open Access Journals (Sweden)

    Marioli-Riga Z.

    2010-06-01

    Full Text Available Polyvinyl alcohol - carbon nanotube (PVA-CNT fibers had been embedded to glass fiber reinforced polymers (GFRP for the structural health monitoring of the composite material. The addition of the conductive PVA-CNT fiber to the nonconductive GFRP material aimed to enhance its sensing ability by means of the electrical resistance measurement method. The test specimen’s response to mechanical load and the in situ PVA-CNT fiber’s electrical resistance measurements were correlated for sensing and damage monitoring purposes. The embedded PVA-CNT fiber worked as a sensor in GFRP coupons in tensile loadings. Sensing ability of the PVA-CNT fibers was also demonstrated on an integral composite structure. PVA-CNT fiber near the fracture area of the structure recorded very high values when essential damage occurred to the structure. A finite element model of the same structure was developed to predict axial strains at locations of the integral composite structure where the fibers were embedded. The predicted FEA strains were correlated with the experimental measurements from the PVA-CNT fibers. Calculated and experimental values were in good agreement, thus enabling PVA-CNT fibers to be used as strain sensors.

  18. The concept of floating electrode for contact-less electrochemical measurements: Application to reinforcing steel-bar corrosion in concrete

    International Nuclear Information System (INIS)

    Keddam, M.; Novoa, X.R.; Vivier, V.

    2009-01-01

    The concept of floating electrode is introduced for defining the common electrochemical behaviour of any non-connected, electronically conducting, body immersed in an electrolytic medium. The emphasis is put on both its own polarisation features and its influence on the d.c. and a.c. current and potential across the cell, hence the feasibility, among others, of contact-less electrochemical measurements on floating electrodes. Application to reinforcing steel bars in concrete is investigated by numerical computation of the a.c. current and potential fields in a broad range of concrete resistivity, interfacial resistance and capacitance. Impedance defined in a 4-electrode configuration, when rationalised against the concrete resistivity, is shown to provide, within a realistic range of parameters, a practical mean to access the properties of the bar-concrete interface.

  19. Experimental Study on Basic Mechanical Properties of BFRP Bars

    Science.gov (United States)

    Fan, Xiaochun; Xu, Ting; Zhou, Zhengrong; Zhou, Xun

    2017-10-01

    Basalt Fiber Reinforced Polymer (BFRP) bars have the advantages of corrosion resistance, high strength, light weight, good dielectric properties, and they are new type of green reinforced alternative material. In order to determine the mechanical properties of BFRP bars, the tensile strength of basalt fiber bars was necessary to be studied. The diameters of the basalt fiber bars were compared by means of uniaxial tensile test in this article. Then the stress-strain curve can be drawn out. The results show that the stress - strain curve of BFRP bars present straight line relation, and there is no sign before failure; there is no yield platform on the stress-strain curve of BFRP bars, which are typical brittle material;the tensile strength of BFRP bars is about 3 times higher than that of ordinary steel bars. and the elastic modulus is about 1/5 of that of ordinary steel; the ultimate tensile strength of BFRP bars varies little with the increase of diameter, but there exist some differences in modulus values.

  20. Effect of fabrication processes on mechanical properties of glass fiber reinforced polymer composites for 49 meter (160 foot) recreational yachts

    Science.gov (United States)

    Kim, Dave (dea-wook); Hennigan, Daniel John; Beavers, Kevin Daniel

    2010-03-01

    Polymer composite materialsoffer high strength and stiffness to weight ratio, corrosion resistance, and total life cost reductions that appeal to the marine industry. The advantages of composite construction have led to their incorporation in U.S. yacht hull structures over 46 meters (150 feet) in length. In order to construct even larger hull structures, higher quality composites with a lower cost production techniques need to be developed. In this study, the effect of composite hull fabrication processes on mechanical properties of glass fiber reinforced plastic(GFRP) composites is presented. Fabrication techniques used in this study are hand lay-up (HL), vacuum infusion (VI), and hybrid (HL+VI) processes. Mechanical property testing includes: tensile, compressive, and ignition loss sample analysis. Results demonstrate that the vacuum pressure implemented during composite fabrication has an effect on mechanical properties. The VI processed GFRP yields improved mechanical properties in tension/compression strengths and tensile modulus. The hybrid GFRP composites, however, failed in a sequential manor, due to dissimilar failure modes in the HL and VI processed sides. Fractography analysis was conducted to validate the mechanical property testing results

  1. GLASS FIBERS – MODERN METHOD IN THE WOOD BEAMS REINFORCEMENT

    Directory of Open Access Journals (Sweden)

    Cătălina IANĂŞI

    2017-05-01

    Full Text Available : One of the defining goals of this paper is getting new resistant material which combine the qualities of basic materials that get into its composition but not to borrow from them their negative properties. Specifically, the use of GFRP composite materials as reinforcement for wood beams under bending loads requires paying attention to several aspects of the problem such as the number of the composite layers applied on the wood beams. The results obtained in this paper indicate that the behavior of reinforced beams is totally different from that of un-reinforced one. The main conclusion of the tests is that the tensioning forces allow beam taking a maximum load for a while, something that is particularly useful when we consider a real construction, The experiments have shown that the method of increasing resistance of wood constructions with composite materials is good for it and easy to implement.

  2. Moisture Absorption/Desorption Effects on Flexural Property of Glass-Fiber-Reinforced Polyester Laminates: Three-Point Bending Test and Coupled Hygro-Mechanical Finite Element Analysis

    Directory of Open Access Journals (Sweden)

    Xu Jiang

    2016-08-01

    Full Text Available Influence of moisture absorption/desorption on the flexural properties of Glass-fibre-reinforced polymer (GFRP laminates was experimentally investigated under hot/wet aging environments. To characterize mechanical degradation, three-point bending tests were performed following the ASTM test standard (ASTM D790-10A. The flexural properties of dry (0% Mt/M∞, moisture unsaturated (30% Mt/M∞ and 50% Mt/M∞ and moisture saturated (100% Mt/M∞ specimens at both 20 and 40 °C test temperatures were compared. One cycle of moisture absorption-desorption process was considered in this study to investigate the mechanical degradation scale and the permanent damage of GFRP laminates induced by moisture diffusion. Experimental results confirm that the combination of moisture and temperature effects sincerely deteriorates the flexural properties of GFRP laminates, on both strength and stiffness. Furthermore, the reducing percentage of flexural strength is found much larger than that of E-modulus. Unrecoverable losses of E-modulus (15.0% and flexural strength (16.4% for the GFRP laminates experiencing one cycle of moisture absorption/desorption process are evident at the test temperature of 40 °C, but not for the case of 20 °C test temperature. Moreover, a coupled hygro-mechanical Finite Element (FE model was developed to characterize the mechanical behaviors of GFRP laminates at different moisture absorption/desorption stages, and the modeling method was subsequently validated with flexural test results.

  3. Cyclic behavior, development, and characteristics of a ductile hybrid fiber-reinforced polymer (DHFRP) for reinforced concrete members

    Science.gov (United States)

    Hampton, Francis Patrick

    Reinforced concrete (R/C) structures especially pavements and bridge decks that constitute vital elements of the infrastructure of all industrialized societies are deteriorating prematurely. Structural repair and upgrading of these structural elements have become a more economical option for constructed facilities especially in the United States and Canada. One method of retrofitting concrete structures is the use of advanced materials. Fiber reinforced polymer (FRP) composite materials typically are in the form of fabric sheets or reinforcing bars. While the strength and stiffness of the FRP is high, composites are inherently brittle, with limited or no ductility. Conventional FRP systems cannot currently meet ductility demand, and therefore, may fail in a catastrophic failure mode. The primary goal of this research was to develop an optimized prototype 10-mm diameter DHFRP bar. The behavior of the bar under full load reversals to failure was investigated. However, this bar first needed to be designed and manufactured in the Fibrous Materials Research at Drexel University. Material properties were determined through testing to categorize the strength properties of the DHFRP. Similitude was used to demonstrate the scaling of properties from the original model bars. The four most important properties of the DHFRP bars are sufficient strength and stiffness, significant ductility for plasticity to develop in the R/C section, and sufficient bond strength for the R/C section to develop its full strength. Once these properties were determined the behavior of reinforced concrete members was investigated. This included the testing of prototype-size beams under monotonic loading and model and prototype beam-columns under reverse cyclic loading. These tests confirmed the large ductility exhibited by the DHFRP. Also the energy absorption capacity of the bar was demonstrated by the hysteretic behavior of the beam-columns. Displacement ductility factors in the range of 3

  4. Finite Element Simulation of Aluminium/GFRP Fibre Metal Laminate under Tensile Loading

    Science.gov (United States)

    Merzuki, M. N. M.; Rejab, M. R. M.; Romli, N. K.; Bachtiar, D.; Siregar, J.; Rani, M. F.; Salleh, Salwani Mohd

    2018-03-01

    The response of a fibre metal laminate (FML) model to the tensile loading is predicted through a computational approach. The FML consisted with layers of aluminum alloy and embedded with one layer of composite material, Glass fibre Reinforced Plastic (GFRP). The glass fibre and aluminium alloy 2024-0 was laminated by using thermoset epoxy. A compression moulding technique was used in the process of a FML fabrication. The aluminium has been roughen by a metal sanding method which to improve the bonding between the fibre and metal layer. The main objective of this paper is to determine the failure behaviour of the FML under the tensile loading. The responses on the FML under the tensile loading were numerically performed. The FML was modelled and analysed by using Abaqus/CAE 6.13 version. Based on the experimental and FE data of the tensile, the ultimate tensile stress is 120 MPa where delamination and fibre breakage happened. A numerical model was developed and agreed well with the experimental results. The laminate has an inelastic respond to increase the tensile loads which due to the plasticity of the aluminium layers.

  5. Improvement of the mode II interface fracture toughness of glass fiber reinforced plastics/aluminum laminates through vapor grown carbon fiber interleaves.

    Science.gov (United States)

    Ning, Huiming; Li, Yuan; Hu, Ning; Cao, Yanping; Yan, Cheng; Azuma, Takesi; Peng, Xianghe; Wu, Liangke; Li, Jinhua; Li, Leilei

    2014-06-01

    The effects of acid treatment, vapor grown carbon fiber (VGCF) interlayer and the angle, i.e., 0° and 90°, between the rolling stripes of an aluminum (Al) plate and the fiber direction of glass fiber reinforced plastics (GFRP) on the mode II interlaminar mechanical properties of GFRP/Al laminates were investigated. The experimental results of an end notched flexure test demonstrate that the acid treatment and the proper addition of VGCF can effectively improve the critical load and mode II fracture toughness of GFRP/Al laminates. The specimens with acid treatment and 10 g m -2 VGCF addition possess the highest mode II fracture toughness, i.e., 269% and 385% increases in the 0° and 90° specimens, respectively compared to those corresponding pristine ones. Due to the induced anisotropy by the rolling stripes on the aluminum plate, the 90° specimens possess 15.3%-73.6% higher mode II fracture toughness compared to the 0° specimens. The improvement mechanisms were explored by the observation of crack propagation path and fracture surface with optical, laser scanning and scanning electron microscopies. Moreover, finite element analyses were carried out based on the cohesive zone model to verify the experimental fracture toughness and to predict the interface shear strength between the aluminum plates and GFRP laminates.

  6. Collaboration of polymer composite reinforcement and cement concrete

    Science.gov (United States)

    Khozin, V. G.; Gizdatullin, A. R.

    2018-04-01

    The results of experimental study of bond strength of cement concrete of different types with fiber reinforcing polymer (FRP) bars are reported. The reinforcing bars were manufactured of glass fibers and had a rebar with different types of the surface relief formed by winding a thin strip impregnated with a binder or by “sanding”. The pullout tests were carried out simultaneously for the steel reinforcing ribbed bars A400. The impact of friction, adhesion and mechanical bond on the strength of bonds between FRP and concrete was studied. The influence of the concrete strength and different operation factors on the bond strength of concrete was evaluated.

  7. Corrosion Assessment of Steel Bars Used in Reinforced Concrete Structures by Means of Eddy Current Testing

    Science.gov (United States)

    de Alcantara, Naasson P.; da Silva, Felipe M.; Guimarães, Mateus T.; Pereira, Matheus D.

    2015-01-01

    This paper presents a theoretical and experimental study on the use of Eddy Current Testing (ECT) to evaluate corrosion processes in steel bars used in reinforced concrete structures. The paper presents the mathematical basis of the ECT sensor built by the authors; followed by a finite element analysis. The results obtained in the simulations are compared with those obtained in experimental tests performed by the authors. Effective resistances and inductances; voltage drops and phase angles of wound coil are calculated using both; simulated and experimental data; and demonstrate a strong correlation. The production of samples of corroded steel bars; by using an impressed current technique is also presented. The authors performed experimental tests in the laboratory using handmade sensors; and the corroded samples. In the tests four gauges; with five levels of loss-of-mass references for each one were used. The results are analyzed in the light of the loss-of-mass and show a strong linear behavior for the analyzed parameters. The conclusions emphasize the feasibility of the proposed technique and highlight opportunities for future works. PMID:26712754

  8. Corrosion Assessment of Steel Bars Used in Reinforced Concrete Structures by Means of Eddy Current Testing

    Directory of Open Access Journals (Sweden)

    Naasson P. de Alcantara

    2015-12-01

    Full Text Available This paper presents a theoretical and experimental study on the use of Eddy Current Testing (ECT to evaluate corrosion processes in steel bars used in reinforced concrete structures. The paper presents the mathematical basis of the ECT sensor built by the authors; followed by a finite element analysis. The results obtained in the simulations are compared with those obtained in experimental tests performed by the authors. Effective resistances and inductances; voltage drops and phase angles of wound coil are calculated using both; simulated and experimental data; and demonstrate a strong correlation. The production of samples of corroded steel bars; by using an impressed current technique is also presented. The authors performed experimental tests in the laboratory using handmade sensors; and the corroded samples. In the tests four gauges; with five levels of loss-of-mass references for each one were used. The results are analyzed in the light of the loss-of-mass and show a strong linear behavior for the analyzed parameters. The conclusions emphasize the feasibility of the proposed technique and highlight opportunities for future works.

  9. Mechanical Properties of Steel-FRP Composite Bars under Tensile and Compressive Loading

    Directory of Open Access Journals (Sweden)

    Zeyang Sun

    2017-01-01

    Full Text Available The factory-produced steel-fiber reinforced polymer composite bar (SFCB is a new kind of reinforcement for concrete structures. The manufacturing technology of SFCB is presented based on a large number of handmade specimens. The calculated stress-strain curves of ordinary steel bar and SFCB under repeated tensile loading agree well with the corresponding experimental results. The energy-dissipation capacity and residual strain of both steel bar and SFCB were analyzed. Based on the good simulation results of ordinary steel bar and FRP bar under compressive loading, the compressive behavior of SFCB under monotonic loading was studied using the principle of equivalent flexural rigidity. There are three failure modes of SFCB under compressive loading: elastic buckling, postyield buckling, and no buckling (ultimate compressive strength is reached. The increase in the postyield stiffness of SFCB rsf can delay the postyield buckling of SFCB with a large length-to-diameter ratio, and an empirical equation for the relationship between the postbuckling stress and rsf is suggested, which can be used for the design of concrete structures reinforced by SFCB to consider the effect of reinforcement buckling.

  10. IPS-Empress II inlay-retained fixed partial denture reinforced with zirconia bar: three-dimensional finite element and in-vitro studies.

    Science.gov (United States)

    Kermanshah, Hamid; Geramy, Allahyar; Ebrahimi, Shahram Farzin; Bitaraf, Tahereh

    2012-12-01

    This study evaluated von Mises stress distribution, flexural strength and interface micrographs of IPS-Empress II (IPS) inlay-retained fixed partial dentures (IRFPD) reinforced with Zirconia bars (Zb). In the Finite element analysis, six three-dimensional models of IRFPD were designed using Solid Works 2006. Five models were reinforced with different Zb and a model without Zb was considered as a control. The bridges were loaded by 200 and 500 N forces at the middle of the pontic on the occlusal surface. Subsequently, von Mises stress and displacement of the models were evaluated along a defined path. In the experimental part, 21 bar shape specimens were fabricated from lithium disilicate and zirconia ceramic in three different designs. The zirconia-IPS interfaces and the fractured surfaces of flexural test were observed using SEM. In the connector area, von Mises stress and displacement of the models with Zb under a load of 500 N were decreased compared to the model without the Zb; however, this difference was not considerable at a load of 200 N. In the mesial connector, Von Mises stress and displacement was decreased from 12.5 Mpa for the control model tested at 500 N to 7.0 Mpa for the model with Zb and from 0.0050-0.0041 mm, respectively. SEM analyses showed that, before fracture, interfacial gaps were not observed along the interfaces, but initiated cracks propagated along the interfaces after flexural loading. IPS IRFPD reinforced by Zb can tolerate higher stresses while still functioning effectively and the interfaces may have desirable adaption.

  11. Stripping demolition of reinforced concrete by electric heating method

    International Nuclear Information System (INIS)

    Nakagawa, Wahei; Nishita, Kiwamu; Kasai, Yoshio

    1993-01-01

    The present paper describes the procedures and results of a series of experiments the authors conducted to verify the efficiency of the electric heating method, previously proposed for so-called stripping demolition by applying electric current through reinforcing bars. In this method, a low voltage high current is run from one end to the other of a reinforcing bar or bars existing in a concrete structure, inducing intense heat in the bar(s) which in its turn brings about cracks in the surrounding concrete mass, facilitating secondary demolition by hammer picks or other means. The experiments were performed on full-scale biological shield wall mock-ups of a BWR and a small reactor. The results of the experiments are summarized as follows. (1) When electric current is applied through reinforcing bars, the bond between concrete and bars is loosened, and cracks start from one bar and progress toward other bars. Under appropriate conditions, the cracks in concrete run from the contact surface at one bar all the way to its the contact surface on another bar. (2) Cracks appear and grow only between two electrodes between which current is applied, not extending out of the area thus defined. (3) The concrete in the region closer to a current-bearing bar is intensely heated, whereas the concrete far from the bars remains nearly unheated. (4) Concrete walls after electric heating of bars disintegrates, if demolished with hammers, with the covering concrete are removed from the remaining portion of the structure together with heated bars, in shapes of flakes. (5) The reinforced concrete collapses in massive pieces of concrete, without generating much dust as is the case with the demolition of a concrete structure not heated by electricity. Results of the experiments show that the electric heating method is worth applying also to the demolition of nuclear power plants where concrete in the radioactivated surface region of shield walls needs to be stripped off in flakes

  12. Effect of fabrication processes on mechanical properties of glass fiber reinforced polymer composites for 49 meter (160 foot recreational yachts

    Directory of Open Access Journals (Sweden)

    Dave (Dae-Wook Kim

    2010-03-01

    Full Text Available Polymer composite materials offer high strength and stiffness to weight ratio, corrosion resistance, and total life cost reductions that appeal to the marine industry. The advantages of composite construction have led to their incorporation in U.S. yacht hull structures over 46 meters (150 feet in length. In order to construct even larger hull structures, higher quality composites with lower cost production techniques need to be developed. In this study, the effect of composite hull fabrication processes on mechanical properties of glass fiber reinforced plastic (GFRP composites is presented. Fabrication techniques investigated during this study are hand lay-up (HL, vacuum infusion (VI, and hybrid (HL + VI processes. Mechanical property testing includes: tensile, compressive, and ignition loss sample analysis. Results demonstrate that the vacuum pressure implemented during composite fabrication has an effect on mechanical properties. The VI processed GFRP yields improved mechanical properties in tension/compression strengths and tensile modulus. The hybrid GFRP composites, however, failed in a sequential manor, due to dissimilar failure modes in the HL and VI processed sides. Fractography analysis was conducted to validate the mechanical property testing results.

  13. EFFECT OF GAMMA RAY IRRADIATION ON INTERLAMINAR SHEAR STRENGTH OF GLASS FIBER REINFORCED PLASTICS AT 77 K

    International Nuclear Information System (INIS)

    Nishimura, A.; Nishijima, S.; Izumi, Y.

    2008-01-01

    It is known that an organic material is damaged by gamma ray irradiation, and the strength after irradiation has dependence on the gamma ray dose. These issues are important not only to make global understanding of electric insulating performance of glass fiber reinforced plastics (GFRP) under irradiation condition but also to develop new insulation materials. This paper presents the dependence of fracture mode and interlaminar shear strength (ILSS) on the material and the gamma ray irradiation effect on the fracture mode and the ILSS. 6 mm radius loading nose and supports were used to prompt ILS fracture for a short beam test. A 2.5 mm thick small specimen machined out of a 13 mm thick G-10CR GFRP plate (sliced specimen) showed lower ILSS and translaminar shear (TLS) fracture, although the same size specimen prepared from a 2.5 mm G-10CR GFRP plate (non-sliced specimen) showed ILS fracture and the higher ILSS. Both type of specimens showed the degradation of ILSS after gamma ray irradiation. The fracture mode of the non-sliced specimen changed from ILS to TLS fracture and no bending fracture was observed. The resistance to shear deformation of glass cloth/epoxy laminate structure would be damaged by the irradiation

  14. The influence of stiffeners on axial crushing of glass-fabric-reinforced epoxy composite shells

    Directory of Open Access Journals (Sweden)

    A. Vasanthanathan

    2017-01-01

    Full Text Available A generic static and impact experimental procedure has been developed in this work aimed at improving the stability of glass fabric reinforced epoxy shell structures by bonding with axial stiffeners. Crashworthy structures fabricated from composite laminate with stiffeners would offer energy absorption superior to metallic structures under compressive loading situations. An experimental material characterisation of the glass fabric reinforced epoxy composite under uni-axial tension has been carried out in this study. This work provides a numerical simulation procedure to describe the static and dynamic response of unstiffened glass fabric reinforced epoxy composite shell (without stiffeners and stiffened glass fabric reinforced epoxy composite shell (with axial stiffeners under static and impact loading using the Finite Element Method. The finite element calculation for the present study was made with ANSYS®-LS-DYNA® software. Based upon the experimental and numerical investigations, it has been asserted that glass fabric reinforced epoxy shells stiffened with GFRP stiffeners are better than unstiffened glass fabric reinforced epoxy shell and glass fabric reinforced epoxy shell stiffened with aluminium stiffeners. The failure surfaces of the glass fabric reinforced epoxy composite shell structures tested under impact were examined by SEM.

  15. An Experimental Evaluation of Mechanical Properties of Hybrid Reinforcements

    Science.gov (United States)

    Sai Kumar, A.; Ganesan, G.; Karthikeyan, K.

    2017-07-01

    This paper presents the mechanical properties of unidirectional hybrid reinforcements formed from continuous fibres impregnated with a fibre binding material which are used for reinforcing the concrete. Recently FRP (Fibre Reinforced Polymer) manufacturers and suppliers have been increased all over the world because of the superior performance of FRP products in the construction industry. Its non-corrosive nature has turned the attention of many researchers to make several studies on different type of FRP products. Through a vast research, several standards also have been formulated. In this regard a new combination of FRP materials is tried in this paper and its properties have been derived. Carbon fibre and glass fibres fuse in this study to form a new hybrid rebar. The design properties such as tensile strength, tensile modulus, and compressive strength have been studied as per ASTM standards and it has been identified that the Hybrid rebar show a superior performance in comparison with GFRP (Glass FRP) and Steel rebars. This extraordinary performance of hybrid composite material increases the extensive engineering applications such as transport industry, aeronautics, naval, automotive industries.

  16. Monitoring Poisson's ratio of glass fiber reinforced composites as damage index using biaxial Fiber Bragg Grating sensors

    OpenAIRE

    Yılmaz, Çağatay; Yilmaz, Cagatay; Akalın, Çağdaş; Akalin, Cagdas; Kocaman, Esat Selim; Suleman, A.; Yıldız, Mehmet; Yildiz, Mehmet

    2016-01-01

    Damage accumulation in Glass Fiber Reinforced Polymer (GFRP) composites is monitored based on Poisson's ratio measurements for three different fiber stacking sequences subjected to both quasi-static and quasi-static cyclic tensile loadings. The sensor systems utilized include a dual-extensometer, a biaxial strain gage and a novel embedded-biaxial Fiber Bragg Grating (FBG) sensor. These sensors are used concurrently to measure biaxial strain whereby the evolution of Poisson's ratio as a functi...

  17. Load carrying capacity of RCC beams by replacing steel reinforcement bars with shape memory alloy bars

    Science.gov (United States)

    Bajoria, Kamal M.; Kaduskar, Shreya S.

    2016-04-01

    In this paper the structural behavior of reinforced concrete (RC) beams with smart rebars under two point loading system has been numerically studied, using Finite Element Method. The material used in this study is Super-elastic Shape Memory Alloys (SE SMAs) which contains nickel and titanium. In this study, different quantities of steel and SMA rebars have been used for reinforcement and the behavior of these models under two point bending loading system is studied. A comparison of load carrying capacity for the model between steel reinforced concrete beam and the beam reinforced with S.M.A and steel are performed. The results show that RC beams reinforced with combination of shape memory alloy and steel show better performance.

  18. A Review of Natural Joint Systems and Numerical Investigation of Bio-Inspired GFRP-to-Steel Joints

    Directory of Open Access Journals (Sweden)

    Evangelos I. Avgoulas

    2016-07-01

    Full Text Available There are a great variety of joint types used in nature which can inspire engineering joints. In order to design such biomimetic joints, it is at first important to understand how biological joints work. A comprehensive literature review, considering natural joints from a mechanical point of view, was undertaken. This was used to develop a taxonomy based on the different methods/functions that nature successfully uses to attach dissimilar tissues. One of the key methods that nature uses to join dissimilar materials is a transitional zone of stiffness at the insertion site. This method was used to propose bio-inspired solutions with a transitional zone of stiffness at the joint site for several glass fibre reinforced plastic (GFRP to steel adhesively bonded joint configurations. The transition zone was used to reduce the material stiffness mismatch of the joint parts. A numerical finite element model was used to identify the optimum variation in material stiffness that minimises potential failure of the joint. The best bio-inspired joints showed a 118% increase of joint strength compared to the standard joints.

  19. Reinforcement Data for Fire Safety Design

    DEFF Research Database (Denmark)

    Hertz, Kristian Dahl

    2004-01-01

    Idealized materials data are derived from a number of test series reported in the literature and made by the author. The data cover a variety of reinforcing steels from mild steel, deformed bars and cold worked bars to cold drawn prestressing steels. Processes are described, which are responsible...

  20. Verification of Properties of Concrete Reinforcement Bars: Nigeria ...

    African Journals Online (AJOL)

    Nekky Umera

    ribbed steel bars used in Nigeria's structural concrete practice to relevant ... cases of structural failure have recently become frequent, especially ... Page 4 ..... Nwabuokei S.O.(2007) “The Nigerian Steel Industry: Delta Steel Company.

  1. Can Plant-Based Natural Flax Replace Basalt and E-Glass for Fiber-Reinforced Polymer Tubular Energy Absorbers? A Comparative Study on Quasi-Static Axial Crushing

    Directory of Open Access Journals (Sweden)

    Libo Yan

    2017-12-01

    Full Text Available Using plant-based natural fibers to substitute glass fibers as reinforcement of composite materials is of particular interest due to their economic, technical, and environmental significance. One potential application of plant-based natural fiber reinforced polymer (FRP composites is in automotive engineering as crushable energy absorbers. Current study experimentally investigated and compared the energy absorption efficiency of plant-based natural flax, mineral-based basalt, and glass FRP (GFRP composite tubular energy absorbers subjected to quasi-static axial crushing. The effects of number of flax fabric layer, the use of foam filler and the type of fiber materials on the crashworthiness characteristics, and energy absorption capacities were discussed. In addition, the failure mechanisms of the hollow and foam-filled flax, basalt, and GFRP tubes in quasi-static axial crushing were analyzed and compared. The test results showed that the energy absorption capabilities of both hollow and foam-filled energy absorbers made of flax were superior to the corresponding energy absorbers made of basalt and were close to energy absorbers made of glass. This study, therefore, indicated that flax fiber has the great potential to be suitable replacement of basalt and glass fibers for crushable energy absorber application.

  2. Durability study of neat/nanophased GFRP composites subjected to different environmental conditioning

    International Nuclear Information System (INIS)

    Zainuddin, S.; Hosur, M.V.; Zhou, Y.; Kumar, Ashok; Jeelani, S.

    2010-01-01

    Experimental investigations on the durability of E-glass/nanoclay-epoxy composites are reported. SC-15 epoxy system was modified using 1-2 wt.% of nanoclay. Extent of clay platelet exfoliation in epoxy was evaluated using X-ray diffraction (XRD). Glass fiber reinforced plastic (GFRP) composite panels were fabricated using modified epoxy and exposed to four different conditions, i.e. hot (elevated temperature-dry, wet: 60 and 80 deg. C) and cold (subzero-dry, wet) for 15, 45 and 90 days. Weight change due to conditioning, quasi-static flexure and micrographic characterization were studied on the conditioned samples. Room temperature samples were also tested for baseline consideration. XRD results showed exfoliation of clay platelets in nanoclay-epoxy samples with decrease in peak intensity and increase in interplanar spacing. Samples subjected to hot-wet conditions showed higher percentage weight gain with a maximum of 4.25% in neat and 3.1% in 2 wt.% samples. Flexural tests results showed degradation with increasing time. Maximum degradation were observed for hot-wet (80 deg. C) for 90 days neat samples, i.e. 22.6% and 29.8% reduction in flexural strength and stiffness, respectively. However, less degradation was noticed for nanophased composites under similar conditions. Scanning electron microscopy (SEM) results of failed samples showed better interfacial bonding in nanophased composites.

  3. Effect Of Age And Concrete Cover Thickness On Steel Reinforcement Corrosion At Splash Zone In Reinforced Concrete Hydraulic Structures

    Directory of Open Access Journals (Sweden)

    Nada M. Al- Galawi

    2015-08-01

    Full Text Available Corrosion of reinforcing steel bars in reinforced concrete is considered as one of the biggest problems that face countries overlooking to the Arabian Gulf including Iraq. The research aims to study the effect of the corrosion of steel bars in concrete structures that are exposed to wetting and drying via waves. Reinforced concrete samples were exposed to marine simulated environment for 90 days using prepared system for this purpose. At the end of exposure period polarization test was implemented to measure the actual corrosion rate in each sample. After that the corrosion process was accelerated using impressed current technique by applying a constant electric current DC to the reinforcing bars. Depending on the corrosion current in natural conditions which was measured in polarization test periods of exposing samples to accelerated corrosion current so as to maintain virtual exposure ages of 5 and 25 years of exposure to natural corrosion were calculated. The results showed a remarkable increase in the corrosion current of steel bars in samples that had lower concrete cover thickness. The increase in the cover thickness from 20mm to 40 and 65 mm had a significant effect on reducing the corrosion current at the age of 90 days to about 70 of its original value in both cases. At the virtual exposure age of 5 years the reduction percentage in the corrosion current resulted from increasing cover thickness from 20mm to 40 and 65 mm were 43 and 79 respectively.

  4. TEMP-STRESS analysis of a reinforced concrete vessel under internal pressure

    International Nuclear Information System (INIS)

    Marchertas, A.H.; Kennedy, J.M.; Pfeiffer, P.A.

    1987-01-01

    The TEMP-STRESS FEM represents an axisymmetric simulation of the reinforced concrete vessel to internal pressurization. The information shows the global deformation, the state of strain/stress within the containment vessel with respect to the imposed pressures. Thus, the location and progress of concrete cracking, the stretching of the liner and the reinforcing bars and final failure are indicated through the entire loading range. Equilibrium of the entire system is assured at definite loading increments. With the progress of concrete cracking, the resisting load is continuously transferred to the reinforcing bars and the liner. Thus, after the tensile strength is exceeded and the concrete stress is set to zero, the internal pressures are entirely resisted by the liner and the reserve strength of the reinforcing bars. The reinforcing bars are mechanically connected to each other by splices, the ultimate strength of which is less than that of the rebars themselves. The corresponding strain at this limiting stress is lower than the ultimate strain of the liner. Therefore, the specified ultimate strength of the splices limits the pressurization of the vessel. Furthermore, once any of the splices fail, then load is transferred to the adjacent members, causing their failure and general failure of the vessel. (orig./HP)

  5. Analytical model of asymmetrical Mixed-Mode Bending test of adhesively bonded GFRP joint

    Czech Academy of Sciences Publication Activity Database

    Ševčík, Martin; Hutař, Pavel; Vassilopoulos, Anastasios P.; Shahverdi, M.

    2015-01-01

    Roč. 9, č. 34 (2015), s. 237-246 ISSN 1971-8993 R&D Projects: GA MŠk(CZ) EE2.3.30.0063; GA ČR GA15-09347S Institutional support: RVO:68081723 Keywords : GFRP materials * Mixed-Mode bending * Fiber bridging * Analytical model Subject RIV: JL - Materials Fatigue, Friction Mechanics

  6. Behavior of Epoxy-Coated Textured Reinforcing Bars

    Science.gov (United States)

    2018-04-01

    Cracking in bridge decks is a common but difficult problem to control. Both research and experience show that the use of epoxy-coated reinforcement, which is mandated by most state departments of transportation (DOTs) for bridge decks, increases c...

  7. Corrosion performance of epoxy-coated reinforcement in aggressive environments

    Science.gov (United States)

    Vaca Cortes, Enrique

    The objective of this research was to investigate the integrity and corrosion performance of epoxy-coated reinforcement in aggressive environments. A series of experimental studies were conducted: (a) hot water immersion and knife adhesion testing for assessment of coating adhesion; (b) materials and procedures for repairing coating damage; (c) degree of mechanical damage caused during concrete placement when using metal head and rubber head vibrators; (d) accelerated corrosion of coated bars embedded in macrocell and beam specimens placed in a corrosive environment for more than four years. The effects of coating condition and amount of damage, repaired vs. unrepaired damage, bar fabrication, and concrete cracking were studied. Regardless of coating condition, the performance of epoxy-coated bars was better than that of uncoated bars. Unlike black bars, coated bars did not exhibit deep pitting or substantial loss of cross section at crack locations. Damage to epoxy coating was the most significant factor affecting corrosion performance. Bars with coating in good condition, without any visible damage, performed best. The greater the size and frequency of damage, the more severe and extensive the amount of corrosion. The performance of bars that were fabricated or bent after coating was worse than that of coated straight bars. Mixing coated and uncoated bars in the same concrete member led to undesirable performance. Patching damaged coating reduced but did not prevent corrosion, particularly at bar ends. The most important factor in coating repair was the type and properties of the patching material. Surface preparation prior to coating had little effect. The absence of cracks in the concrete delayed, but did not prevent the onset of corrosion of coated bars. During consolidation of concrete, rubber head vibrators caused less damage to epoxy-coated reinforcement than did comparable metal heads. Hot water and adhesion tests were useful and practical for evaluating

  8. Study of the behavior of corroded steel bar and convenient method of repairing

    Directory of Open Access Journals (Sweden)

    Nihal Abdelhamid Taha

    2016-08-01

    Full Text Available This paper presents an experimental investigation into the residual strength and mechanical properties of corroded reinforcing bare bars. An attempt has been made to describe firstly the impressed current technique which is commonly used for accelerating reinforcement corrosion. The study compared between two methods of repairing the corroded steel bar, the first one which mostly used by painting the half surface area of corroded bar; and the another one by coating the full surface area of corroded bar. The experimental results show that, the corrosion process alters the external surface of steel bar due to pitting, the residual cross-section of the corroded bar is no longer round and varies considerably along its circumference and its length so the residual diameter is better defined by loss of weight. The rate of corrosion has been calculated by two terms, the term of mass loss rate (MR and the term of penetration rate (CR. The mass loss rate decreased for fully coated bars by 1.7–2 times than half coated bars showing the importance of fully coating bars in corrosion repair. Finally, the reliability of using the galvanostatic method in research work was represented by comparing between the real time and the accelerated time to reach a certain degree of corrosion.

  9. Flexural Performance of Transparent Plastic Bar Reinforced Concrete

    Directory of Open Access Journals (Sweden)

    Byoungil Kim

    2018-02-01

    Full Text Available In this study, experiments were conducted to derive a mix design for improving the flexural performance of light transparent concrete, which is attracting much attention and interest as an interior and exterior material for buildings, so that it could be easily applied in the field as a non-structural element by securing a lightweight, workability, and economic efficiency through the improvement of the concrete mix design and the use of economical materials for promoting its practical use. It was found that the mixing of polyvinyl alcohol (PVA fiber was effective in improving the consistency by preventing the aggregate from floating due to the mixing of lightweight aggregate with a low specific gravity. The flexural performance test results showed that the load transfer factor (LTF from the concrete matrix to the fiber was highest in the test specimens without plastic bars, followed by those with 5 and 10 mm plastic bars, respectively.

  10. GFRP seismic strengthening and structural heath monitoring of Portage Creek Bridge concrete columns

    International Nuclear Information System (INIS)

    Huffman, S.; Bagchi, A.; Mufti, A.; Neale, K.; Sargent, D.; Rivera, E.

    2006-01-01

    Located in Victoria British Columbia (BC), Canada, the Portage Creek Bridge is a 124m long, three-span structure with a reinforced concrete piers and abutments on H piles. The bridge was designed prior to the introduction of current bridge seismic design codes and construction practices. Therefore it was not designed to resist the earthquake forces as required by today's standards. The bridge is on a route classified as a Municipal Disaster Route scheduled to be retrofitted to prevent collapse during a design seismic event, with a return period of 475 years (i.e., an event with 105 probability of exceedance in 50 years). Conventional materials and methods were used to retrofit most of the bridge. The dynamic analysis of the bridge predicted the two tall columns of Pier No. 1 will form plastic hinges under an earthquake resulting an additional shear to the short columns of Pier No. 2. A non-liner static pushover analysis indicated the short columns will not be able to form plastic hinges prior to failure in shear. The innovative solution of Fiber Reinforced Polymer wraps (FRPs) was chosen to strengthen the short columns for shear without increasing the moment capacity. The FRP wraps and the bridge were instrumented as one of 36 demonstration projects across Canada sponsored by ISIS (Intelligent Sensing for Innovative Structure) Canada, federally funded Network of Centers of Excellence, to access the performance of FRP and the use of FOS (Fiber Optic Sensors) for Structural Health Monitoring (SHM). The two columns of the bridge pier were strengthened with GFRP (Glass Fiber Reinforced Polymer) wraps with eight bi-directional rosette type strain gauges and four long gauge fiber optic sensors attached to the outer layer of the wraps. In addition, two 3-D Crossbow accelerometers are installed on the pier cap above the columns and a traffic web-cam mounted above the deck at the pier location. The data is collected through high sped internet line to an interactive web page

  11. The influence of main bar corrosion on bond strength in selfcompacting concrete

    Science.gov (United States)

    Ayop, S. S.; Emhemed, A. N. K.; Jamaluddin, N.; Sadikin, A.

    2017-11-01

    The experimental study was conducted to determine the influence of main bar corrosion on bond strength in self-compacting concrete (SCC). A total 16 tension pullout tests specimens reinforced with 10 mm and 14 mm diameter bar were used for the bond strength test. The properties of SCC were determined from the slump flow, T50cm, V-funnel and L box test. Reinforcing bars in the concrete were submitted to impressed current to accelerate the corrosion of the bar. It was found that the relationship between bond strength and concrete strength in un-corroded specimens differed from that of corroded specimens set in high-strength concrete because of brittleness in the corroded specimens, which caused a sudden loss of bond strength. The results revealed that specimens of un-corroded and corroded showed a higher percentage of bond strength degradation during the pullout tests.

  12. Performance of Hybrid Reinforced Concrete Beam Column Joint: A Critical Review

    Directory of Open Access Journals (Sweden)

    Md Rashedul Kabir

    2016-04-01

    Full Text Available Large residual strain in reinforced concrete structures after a seismic event is a major concern for structural safety and serviceability. Alternative reinforcement materials like fiber-reinforced polymer (FRP have been widely used to mitigate corrosion problems associated with steel. Low modulus of elasticity and brittle behavior compared to steel has made the use of FRP unsuitable in seismic resistant strictures. A combination of steel-FRP reinforcement configuration can address the problem of corrosion. Therefore, introducing a material that shows strong post elastic behavior without any decay due to corrosion is in demand. Shape memory alloy (SMA, a novel material, is highly corrosion resistive and shows super elastic property. Coupling SMA with FRP or steel in the plastic hinge region allows the structure to undergo large deformations, but regains its original shape upon unloading. In this study, the performance characteristics of four previously tested beam-column joints reinforced with different configurations (steel, SMA/steel, glass fiber reinforced polymer (GFRP and SMA/FRP are compared to assess their capacity to endure extreme loading. Experimental results are scrutinized to compare the behavior of these specimens in terms of load-story drift and energy dissipation capacity. SMA/FRP and SMA/Steel couples have been found to be an acceptable approach to reduce residual deformation in beam-column joints with adequate energy dissipation capacity. However, SMA/FRP is superior to SMA/Steel concerning to the corrosion issue in steel.

  13. Behaviour of smart reinforced concrete beam with super elastic shape memory alloy subjected to monotonic loading

    Science.gov (United States)

    Hamid, Nubailah Abd; Ibrahim, Azmi; Adnan, Azlan; Ismail, Muhammad Hussain

    2018-05-01

    This paper discusses the superelastic behavior of shape memory alloy, NiTi when used as reinforcement in concrete beams. The ability of NiTi to recover and reduce permanent deformations of concrete beams was investigated. Small-scale concrete beams, with NiTi reinforcement were experimentally investigated under monotonic loads. The behaviour of simply supported reinforced concrete (RC) beams hybrid with NiTi rebars and the control beam subject to monotonic loads were experimentally investigated. This paper is to highlight the ability of the SMA bars to recover and reduce permanent deformations of concrete flexural members. The size of the control beam is 125 mm × 270 mm × 1000 mm with 3 numbers of 12 mm diameter bars as main reinforcement for compression and 3 numbers of 12 mm bars as tension or hanger bars while 6 mm diameter at 100 mm c/c used as shear reinforcement bars for control beam respectively. While, the minimal provision of 200mm using the 12.7mm of superelastic Shape Memory Alloys were employed to replace the steel rebar at the critical region of the beam. In conclusion, the contribution of the SMA bar in combination with high-strength steel to the conventional reinforcement showed that the SMA beam has exhibited an improve performance in term of better crack recovery and deformation. Therefore the usage of hybrid NiTi with the steel can substantially diminish the risk of the earthquake and also can reduce the associated cost aftermath.

  14. Application of smart BFRP bars with distributed fiber optic sensors into concrete structures

    Science.gov (United States)

    Tang, Yongsheng; Wu, Zhishen; Yang, Caiqian; Wu, Gang; Zhao, Lihua; Song, Shiwei

    2010-04-01

    In this paper, the self-sensing and mechanical properties of concrete structures strengthened with a novel type of smart basalt fiber reinforced polymer (BFRP) bars were experimentally studied, wherein the sensing element is Brillouin scattering-based distributed optical fiber sensing technique. First, one of the smart bars was applied to strengthen a 2m concrete beam under a 4-points static loading manner in the laboratory. During the experiment, the bar can measure the inner strain changes and monitor the randomly distributed cracks well. With the distributed strain information along the bar, the distributed deformation of the beam can be calculated, and the structural health can be monitored and evaluated as well. Then, two smart bars with a length of about 70m were embedded into a concrete airfield pavement reinforced by long BFRP bars. In the field test, all the optical fiber sensors in the smart bars survived the whole concrete casting process and worked well. From the measured data, the concrete cracks along the pavement length can be easily monitored. The experimental results also confirmed that the bars can strengthen the structures especially after the yielding of steel bars. All the results confirm that this new type of smart BFRP bars show not only good sensing performance but also mechanical performance in the concrete structures.

  15. The effect of concrete strength and reinforcement on toughness of reinforced concrete beams

    OpenAIRE

    Carneiro, Joaquim A. O.; Jalali, Said; Teixeira, Vasco M. P.; Tomás, M.

    2005-01-01

    The objective pursued with this work includes the evaluating of the strength and the total energy absorption capacity (toughness) of reinforced concrete beams using different amounts of steel-bar reinforcement. The experimental campaign deals with the evaluation of the threshold load prior collapse, ultimate load and deformation, as well as the beam total energy absorption capacity, using a three point bending test. The beam half span displacement was measured using a displacement transducer,...

  16. [Reinforcement for overdentures on abutment teeth].

    Science.gov (United States)

    Osada, Tomoko

    2006-04-01

    This study investigated the effect of the position of reinforcement wires, differences in artificial teeth, and framework designs on the breaking strength of overdentures. The basal surfaces of composite resin teeth and acrylic resin teeth were removed using a carbide bur. A reinforcement wire or a wrought palatal bar was embedded near the occlusal surface or basal surface. Four types of framework structures were designed : conventional skeleton (skeleton), housing with skeleton (housing), housing plus short metal backing (metal backing), and housing plus long metal backing (double structure). After the wires, bars, and frameworks were sand-blasted with 50 microm Al(2)O(3) powder, they were primed with a metal primer and embedded in a heat-polymerized denture base resin. The breaking strengths (N) and maximum stiffness (N/mm) of two-week aged (37 degrees C) specimens were measured using a bending test (n=8). All data obtained at a crosshead speed of 2.0 mm/min were analyzed by ANOVA/Tukey's test (alpha=0.01). There were no statistical differences between the two kinds of artificial teeth (p>0.01). The wrought palatal bar had significantly higher strength than the reinforcement wire (p0.01). The breaking strength and maximum stiffness of the double structure framework were significantly greater (poverdentures were influenced by the size and position of the reinforcement wires. Double structure frameworks are recommended for overdentures to promote a long-term prognosis without denture breakage.

  17. Development of self-sensing BFRP bars with distributed optic fiber sensors

    Science.gov (United States)

    Tang, Yongsheng; Wu, Zhishen; Yang, Caiqian; Shen, Sheng; Wu, Gang; Hong, Wan

    2009-03-01

    In this paper, a new type of self-sensing basalt fiber reinforced polymer (BFRP) bars is developed with using the Brillouin scattering-based distributed optic fiber sensing technique. During the fabrication, optic fiber without buffer and sheath as a core is firstly reinforced through braiding around mechanically dry continuous basalt fiber sheath in order to survive the pulling-shoving process of manufacturing the BFRP bars. The optic fiber with dry basalt fiber sheath as a core embedded further in the BFRP bars will be impregnated well with epoxy resin during the pulling-shoving process. The bond between the optic fiber and the basalt fiber sheath as well as between the basalt fiber sheath and the FRP bar can be controlled and ensured. Therefore, the measuring error due to the slippage between the optic fiber core and the coating can be improved. Moreover, epoxy resin of the segments, where the connection of optic fibers will be performed, is uncured by isolating heat from these parts of the bar during the manufacture. Consequently, the optic fiber in these segments of the bar can be easily taken out, and the connection between optic fibers can be smoothly carried out. Finally, a series of experiments are performed to study the sensing and mechanical properties of the propose BFRP bars. The experimental results show that the self-sensing BFRP bar is characterized by not only excellent accuracy, repeatability and linearity for strain measuring but also good mechanical property.

  18. Reinforced concrete tomography

    International Nuclear Information System (INIS)

    Mariscotti, M.A.J.; Morixe, M.; Tarela, P.A.; Thieberger, P.

    1997-01-01

    In this paper we describe the technique of reinforced concrete tomography, its historical background, recent technological developments and main applications. Gamma radiation sensitive plates are imprinted with radiation going through the concrete sample under study, and then processed to reveal the presence of reinforcement and defects in the material density. The three dimensional reconstruction, or tomography, of the reinforcement out of a single gammagraphy is an original development alternative to conventional methods. Re-bar diameters and positions may be determined with an accuracy of ± 1 mm 0.5-1 cm, respectively. The non-destructive character of this technique makes it particularly attractive in cases of inhabited buildings and diagnoses of balconies. (author) [es

  19. Distributed Long-Gauge Optical Fiber Sensors Based Self-Sensing FRP Bar for Concrete Structure.

    Science.gov (United States)

    Tang, Yongsheng; Wu, Zhishen

    2016-02-25

    Brillouin scattering-based distributed optical fiber (OF) sensing technique presents advantages for concrete structure monitoring. However, the existence of spatial resolution greatly decreases strain measurement accuracy especially around cracks. Meanwhile, the brittle feature of OF also hinders its further application. In this paper, the distributed OF sensor was firstly proposed as long-gauge sensor to improve strain measurement accuracy. Then, a new type of self-sensing fiber reinforced polymer (FRP) bar was developed by embedding the packaged long-gauge OF sensors into FRP bar, followed by experimental studies on strain sensing, temperature sensing and basic mechanical properties. The results confirmed the superior strain sensing properties, namely satisfied accuracy, repeatability and linearity, as well as excellent mechanical performance. At the same time, the temperature sensing property was not influenced by the long-gauge package, making temperature compensation easy. Furthermore, the bonding performance between self-sensing FRP bar and concrete was investigated to study its influence on the sensing. Lastly, the sensing performance was further verified with static experiments of concrete beam reinforced with the proposed self-sensing FRP bar. Therefore, the self-sensing FRP bar has potential applications for long-term structural health monitoring (SHM) as embedded sensors as well as reinforcing materials for concrete structures.

  20. Experimental Investigation into Corrosion Effect on Mechanical Properties of High Strength Steel Bars under Dynamic Loadings

    Directory of Open Access Journals (Sweden)

    Hui Chen

    2018-01-01

    Full Text Available The tensile behaviors of corroded steel bars are important in the capacity evaluation of corroded reinforced concrete structures. The present paper studies the mechanical behavior of the corroded high strength reinforcing steel bars under static and dynamic loading. High strength reinforcing steel bars were corroded by using accelerated corrosion methods and the tensile tests were carried out under different strain rates. The results showed that the mechanical properties of corroded high strength steel bars were strain rate dependent, and the strain rate effect decreased with the increase of corrosion degree. The decreased nominal yield and ultimate strengths were mainly caused by the reduction of cross-sectional areas, and the decreased ultimate deformation and the shortened yield plateau resulted from the intensified stress concentration at the nonuniform reduction. Based on the test results, reduction factors were proposed to relate the tensile behaviors with the corrosion degree and strain rate for corroded bars. A modified Johnson-Cook strength model of corroded high strength steel bars under dynamic loading was proposed by taking into account the influence of corrosion degree. Comparison between the model and test results showed that proposed model properly describes the dynamic response of the corroded high strength rebars.

  1. Mechanical splicing of superelastic Cu–Al–Mn alloy bars with headed ends

    Science.gov (United States)

    Kise, S.; Mohebbi, A.; Saiidi, M. S.; Omori, T.; Kainuma, R.; Shrestha, K. C.; Araki, Y.

    2018-06-01

    This paper examines the feasibility of mechanical splicing using a steel coupler to connect headed ends of superelastic Cu–Al–Mn alloy (Camalloy) bars and steel reinforcing bars to be used in concrete structures. Although threading of Camalloy is as easy as that of steel, mechanical splicing using threaded ends requires machining of Camalloy bars into dog-bone shape to avoid brittle fracture at the threaded ends. The machining process requires significant time and cost and wastes substantial amount of the material. This paper attempts to resolve this issue by applying mechanical splicing using steel couplers to connect headed ends of Camalloy and steel reinforcing bars. To study its feasibility, we prepare 3 specimens wherein both ends of each Camalloy bar (13 mm diameter and 300 mm length) are connected to steel reinforcing bars. The specimens are tested under monotonic, single-cycle, and full-cycle tension loading conditions. From these tests, we observed (1) excellent superelasticity with recoverable strain of around 6% and (2) large ductility with fracture strain of over 19%. It should be emphasized here that, in all the specimens, ductile fracture occurred at the locations apart from the headed ends. This is in sharp contrast with brittle fracture of headed superelastic Ni–Ti SMA bars, most of which took place around the headed ends. From the results of the microstructural analysis, we identified the following reasons for avoiding brittle fracture at the headed ends: (1) Precipitation hardening increases the strength around the boundary between the straight and headed (tapered) portions, where stress concentration takes place. (2) The strength of the straight portion does not increase significantly up to the ductile fracture if its grain orientation is close to 〈0 0 1〉.

  2. Effect of materials and manufacturing on the bending stiffness of vaulting poles

    Science.gov (United States)

    Davis, C. L.; Kukureka, S. N.

    2012-09-01

    The increase in the world record height achieved in pole vaulting can be related to the improved ability of the athletes, in terms of their fitness and technique, and to the change in materials used to construct the pole. For example in 1960 there was a change in vaulting pole construction from bamboo to glass fibre reinforced polymer (GFRP) composites. The lighter GFRP pole enabled the athletes to have a faster run-up, resulting in a greater take-off speed, giving them more kinetic energy to convert into potential energy and hence height. GFRP poles also have a much higher failure stress than bamboo, so the poles were engineered to bend under the load of the athlete, thereby storing elastic strain energy that can be released as the pole straightens, resulting in greater energy efficiency. The bending also allowed athletes to change their vaulting technique from a style that involved the body remaining almost upright during the vault to one where the athlete goes over the bar with their feet upwards. Modern vaulting poles can be made from GFRP and/or carbon fibre reinforced polymer (CFRP) composites. The addition of carbon fibres maintains the mechanical properties of the pole, but allows a reduction in the weight. The number and arrangement of the fibres determines the mechanical properties, in particular the bending stiffness. Vaulting poles are also designed for an individual athlete to take into account each athlete’s ability and physical characteristics. The poles are rated by ‘weight’ to allow athletes to select an appropriate pole for their ability. This paper will review the development of vaulting poles and the requirements to maximize performance. The properties (bending stiffness and pre-bend) and microstructure (fibre volume fraction and lay-up) of typical vaulting poles will be discussed. Originally published as Davis C L and Kukureka S N (2004) Effect of materials and manufacturing on the bending stiffness of vaulting poles The Engineering of

  3. Deterioration of J-bar reinforcement in abutments and piers.

    Science.gov (United States)

    2011-12-31

    Deterioration and necking of J-bars has been reportedly observed at the interface of the footing and stem wall during the demolition : of older retaining walls and bridge abutments. Similar deterioration has been reportedly observed between the pier ...

  4. Corrosion-induced bond strength degradation in reinforced concrete-Analytical and empirical models

    International Nuclear Information System (INIS)

    Bhargava, Kapilesh; Ghosh, A.K.; Mori, Yasuhiro; Ramanujam, S.

    2007-01-01

    The present paper aims to investigate the relationship between the bond strength and the reinforcement corrosion in reinforced concrete (RC). Analytical and empirical models are proposed for the bond strength of corroded reinforcing bars. Analytical model proposed by Cairns.and Abdullah [Cairns, J., Abdullah, R.B., 1996. Bond strength of black and epoxy-coated reinforcement-a theoretical approach. ACI Mater. J. 93 (4), 362-369] for splitting bond failure and later modified by Coronelli [Coronelli, D. 2002. Corrosion cracking and bond strength modeling for corroded bars in reinforced concrete. ACI Struct. J. 99 (3), 267-276] to consider the corroded bars, has been adopted. Estimation of the various parameters in the earlier analytical model has been proposed by the present authors. These parameters include corrosion pressure due to expansive action of corrosion products, modeling of tensile behaviour of cracked concrete and adhesion and friction coefficient between the corroded bar and cracked concrete. Simple empirical models are also proposed to evaluate the reduction in bond strength as a function of reinforcement corrosion in RC specimens. These empirical models are proposed by considering a wide range of published experimental investigations related to the bond degradation in RC specimens due to reinforcement corrosion. It has been found that the proposed analytical and empirical bond models are capable of providing the estimates of predicted bond strength of corroded reinforcement that are in reasonably good agreement with the experimentally observed values and with those of the other reported published data on analytical and empirical predictions. An attempt has also been made to evaluate the flexural strength of RC beams with corroded reinforcement failing in bond. It has also been found that the analytical predictions for the flexural strength of RC beams based on the proposed bond degradation models are in agreement with those of the experimentally

  5. Steel Bar corrosion monitoring based on encapsulated piezoelectric sensors

    Science.gov (United States)

    Xu, Ying; Tang, Tianyou

    2018-05-01

    The durability of reinforced concrete has a great impact on the structural bearing capacity, while the corrosion of steel bars is the main reason for the degradation of structural durability. In this paper, a new type of encapsulated cement based piezoelectric sensor is developed and its working performance is verified. The consistency of the finite element simulation and the experimental results shows the feasibility of monitoring the corrosion of steel bars using encapsulated piezoelectric sensors. The research results show that the corrosion conditions of the steel bars can be determined by the relative amplitude of the measured signal through the encapsulated piezoelectric sensor.

  6. On the Performance of a Very Large All-GFRP Strut and Tie Structure

    Science.gov (United States)

    Boscato, G.; Mottram, J. T.; Russo, S.

    2014-09-01

    An analysis of the dynamic response of a fiber-reinforced-polymer (FRP) structure serving as a temporary (weather) shelter for the church of S. Maria Paganica in L'Aquila is presented. The church suffered roof collapse during a magnitude 6.3 earthquake in April, 2009. The structure is a rectilinear space frame constructed from built-up members of pultruded profiles and steel bolted FRP gusset plates. It has a maximum height of 32 m, covers an area of 1050 m2, and weighs (only) 120 kN. Foundations are free-standing blocks of reinforced concrete connected, just above the floor of the church, by steel bars 16 mm in diameter. A finite-element analysis (FEA) is used to determine the seismic response of the main section to the FRP structure. The nonlinear FE responses of the structure subjected to design response spectra (in the ultimate limit state) are presented and evaluated.

  7. Sustainable RC Beam-Column Connections with Headed Bars: A Formula for Shear Strength Evaluation

    Directory of Open Access Journals (Sweden)

    Minh-Tung Tran

    2018-02-01

    Full Text Available Beam-column joints are critical regions for reinforced concrete (RC frames subjected to earthquakes. The steel reinforcement is, in general, highly concentrated in these zones. This is why in many cases, headed bars are used. A headed bar is a longitudinal steel reinforcement whose end has a special button added to reduce the bonding length of the steel rebar. This paper establishes a formula predicting the shear strength of exterior RC beam-column connections where the beam longitudinal reinforcements use headed bars. A database was collected, which contained 30 experimental data about the exterior beam-column joints using headed bars and subjected to quasi-static cyclic loading. First, from the collected database, a statistical study was carried out to identify the most influencing parameters on the shear strength of the beam-column joints tested. The three most important parameters were identified and an empirical modified formula was developed based on the formula existing in the standards. The study showed that the results obtained from the modified formula proposed in the present study were closer to the experimental results than that obtained from the formula existing in the standards. Finally, a numerical study was performed on two T-form RC structures and the numerical results were compared with the prediction calculated from the modified formula proposed. For two investigated cases, the proposed formula provided the results in the safety side and the differences with the numerical results were less than 20%. Thus, the proposed formula can be used for a rapid assessment of the shear strength of RC joints using headed bars.

  8. Proyecto de una torre de perforación con perfiles pultrusionados de GFRP

    Directory of Open Access Journals (Sweden)

    Recuero Fornies, Alfonso

    2001-02-01

    Full Text Available The goal of this project was to design a removable and reusable structure (derrick built with pultrusion profiles of GFRP (Glass Fiber Reinforced Polymers. These profiles have better physical and mechanical properties than those commonly used for these structures, such as steel or concrete profiles. A methodology for drilling an oil field is described in this document. The structure has been worked out by computer program. An economical study with a comparison between the structure designed with common materials and with composites is included. An application to different situations where steel design could not be possible is also shown.El proyecto presenta el diseño de una estructura desmontable y reutilizable para la realización de sondeos de petróleo .La estructura ha sido proyectada con perfiles pultrusionados de material compuesto avanzado ya que presentan unas cualidades, tanto físicas como mecánicas, superiores a la de los materiales convencionales. El empleo de estos materiales ha sido justificado desde el punto de vista técnico y económico. A lo largo del artículo se describen las operaciones requeridas en la explotación por sondeos, así como el planteamiento seguido en el cálculo estructural mediante un programa que tiene por objeto el análisis matricial de estructuras de barras. Al final del mismo se hacen una serie de reflexiones sobre las tendencias futuras de estos materiales.

  9. High-performance GFRP materials with glass fibre prepregs; Hochleistungs-Faserverbundwerkstoffe aus UD-Gelegeprepregs

    Energy Technology Data Exchange (ETDEWEB)

    Prause, J.P. [Schichtstoff-Technik, Arnsberg (Germany); Schroeder, K.F. [Wissenschaftliche Verlagsanstalt, Mettmann (Germany)

    1999-07-01

    The US 3M Company is the producer of the 'Scotchply' glass fibre prepreg which results in materials that can withstand higher dynamic loads than conventional glass fibre reinforced plastics. The new materials are used, e.g., for leaf spring construction. The fatigue characteristics of GFRP leaf springs were discussed at the DGM 'Verbundwerkstoffe und Werkstoffverbunde' conference at Kaiserslauter in September 1997. This contribution presents tools for the engineer for calculation of leaf springs in consideration of the expected loads. [German] Bereits frueher konnte nachgewiesen werden, dass mit Glasgarngelegen verstaerkte Kunststoffe dynamisch hoeher beansprucht werden koennen als gleichartige Konstruktionen mit Glasgewebeverstaerkung. Dieser Vorteil wird in der industriellen Praxis genutzt, um den breiten Einsatzbereich von Blattfedern aus Stahl durch solche aus Faserverbundwerkstoffen zu erweitern. Mit Glasfasern verstaerkte Kunststoffe (GFK) sind seit Jahren Stand der Technik. Die Verarbeitung als Gelegeprepreg hat sich oekonomisch und oekologisch als eine guenstige Technologie bewaehrt. Die Prepregs werden im Wickelverfahren in die endgueltige Form gebracht oder zu Platten verpresst, aus denen die gewuenschten Werkstuecke mechanisch herausgearbeitet werden. Eine ideale Ausnutzung aller in UD-Gelegen vorgegebenen Eigenschaften ist die Form der Blattfeder. Werkstoff und Geometrie koennen optimal an die Belastung angepasst werden. Ueber die Ermuedungsfestigkeit von GFK-Blattfedern wurde waehrend der Vortragstagung der DGM 'Verbundwerkstoffe und Werkstoffverbunde' im September 1997 in Kaiserslautern eingehend berichtet. Mit dieser Veroeffentlichung soll dem Ingenieur eine Hilfe gegeben werden, solche Blattfedern entsprechend der spaeteren Beanspruchung zu berechnen. (orig.)

  10. Nonlinear Analysis of External Prestressed Reinforced Concrete Beams with BFRP and CFRP

    Directory of Open Access Journals (Sweden)

    Haleem K. Hussain

    2017-05-01

    Full Text Available The traditional strengthening methods for concrete structure (girders, beams, columns…. consuming time and could be an economical, a new modern repair methods using the Carbon Fiber Reinforced Polymers (CFRP and Basalt Fiber Reinforced Polymer (BFRP as a laminate strips or bars,and considered a competitive solution that will increase the life-cycle of repaired structures. This study investigated the strengthen reinforced concrete girder. Nonlinear analysis have been adopted to the models using FEM analysis (ANSYS to simulate the theoretical results compared with experimental results.Using finite element packages, more efficient and better analyses can be made to fully understand the response of individual structural components and their contribution to a structure as a whole.Three type of material are used in this study as an external prestressed wire (steel, CFRP and BFRP. The prestressed beam is modeled as simply supported beam with two concentrated point load. The results showed that all tested strengthening beam increased the load carryingcapacity of the beams depend on prestressing force. Obtained Result was compared for different type of beam.This study also was enlarged to include using CFRP and BFRPbarwhich are light weight and moredurable, lead to ease of handling and maintenance. The research conducted analytical work to evaluate the effectiveness of concrete beams reinforced normally by the use of CFRP and BFRP bars. The results showed a significant gain in the beam’s ultimate capacities using CFRP bars comparing with beam reinforced with BFRP bar and reference beam

  11. AWWA C303-17 concrete pressure pipe, bar-wrapped, steel-cylinder type

    CERN Document Server

    2017-01-01

    This standard describes the manufacture of concrete pressure pipe, reinforced with a steel cylinder that is helically wrapped with mild steel bar reinforcement, in sizes ranging from 10 in. through 72 in. (250 mm through 1,830 mm), inclusive, and for working pressures up to 400 psi (2,760 kPa).

  12. Effect of electric field in the characterization of pultruded GFRP boron-free composite insulator for the extra high voltage by the ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, Hissae; Silva Junior, Edmilson Jose; Shinohara, Armando Hideki [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil); Xavier, Gustavo Jose Vasconcelos [CHESF, Recife, PE (Brazil); Costa, Edson Guedes [Universidade Federal de Campina Grande (UFCG), PB (Brazil); Lott Neto, Henrique Batista Duffles Teixeira; Britto, Paulo Roberto Ranzan; Fontan, Marcio A.B. [Sistema de Transmissao do Nordeste S.A., Recife, PE (Brazil)

    2016-07-01

    Full text: The pultruded boron-free glass fiber reinforced polymer (GFRP) composite has been widely used material for the electrical insulators in the high, extra and ultra high voltage overhead lines worldwide. In terms of design, the composite insulator has a highly complex geometry and large size. Aging of materials begin as soon as the insulators start their operation due to the strong electric field, mechanical load due to the weight of conductor cables, environment, corona discharge, generation of acids, and as a result, GFRP can fail mechanically by the stress corrosion crack (SCC) and electrical breakdown known as flashover. In order to mitigate the mechanical and electrical failures, the insulators in the field are frequently monitored by visual inspection, infrared thermography, UV detection, variation of measurement of distribution of electric field variation. However, new technologies for characterization and inspection of the composite insulator in the field are required for reliable operation. Imaging characterization using ionizing radiation (X-ray or g-ray) is an interesting technique, however, it can reduce drastically breakdown voltage due to the Townsend discharge, which free electrons are accelerated by an electric field, collide with gas molecules of air, and free additional electrons resulting in an avalanche multiplication that allows an electrical conduction through the air. In this study, in order to evaluate the potential application of ionization radiation for characterization of composite insulator under electric field, testing were conducted in high voltage laboratory by applying voltages up to 640 kV and varying radiation area of the composite insulator. As a result, even though there was an occurrence of flame on Imaging Plate (IP) detector case when it was located near the phase, corona discharge, but no breakdown discharge (flashover) occurred and high quality imaging of radiography could be obtained when X-ray source was employed

  13. Polymer Composite Rebars under Moisture and Mechanical Loading

    Science.gov (United States)

    Adam, Mohamed Ibrahim

    Fiber reinforced polymer (FRP) composites have been increasingly used by the civil engineering construction industry in the past few years. Glass fiber reinforced polymer (GFRP) is one of the most commonly used FRP materials in applications such as a profile member or reinforcing rebars. Lightweight, high strength and excellent corrosion resistance are just a few among the many appealing properties of GFRP rebars. Use of GFRP has been focused on extending the service life of civil engineering structures acting as reinforcement instead of steel. FRP composites also provide opportunities for repair and retrofit of existing structures to extend their service life or to increase their load bearing capacity. However, the higher initial cost of GFRP rebar compared to steel is a current barrier in their widespread usage. Recent advancements in processes such as pultrusion have helped in reducing the cost of the FRP rebar. In addition, a higher initial raw material cost can be offset by the lower lifecycle cost of GFRP rebar compared to steel rebar. These factors are helping in increasing the acceptance of GFRP rebars in construction industry. Availability of technical data on GFRP, especially for long-term performance and under practical loading conditions faced in a real-life application, can help in increasing their acceptance. Although there have been numerous studies to characterize the properties of GFRP in terms of strength, corrosion, fatigue, chemical and physical aging, and natural weathering, most of these studies were limited to material characterization and were not intended for civil engineering applications. For this reason, and to encourage the increased use of GFRP rebars in concrete structures, GFRP rebar has been an important research topic in recent years. Of particular interest are their long-term durability and their susceptibility to degradation that might be initiated by moisture, temperature, and corrosive chemical environments. This is because

  14. Ultrasonic guided wave for monitoring corrosion of steel bar

    Science.gov (United States)

    Liu, Xi; Qin, Lei; Huang, Bosheng

    2018-01-01

    Steel corrosion of reinforced concrete structures has become a serious problem all over the word. In this paper, the work aims at monitoring steel corrosion using ultrasonic guided wave (UGW). Ultrasonic guided wave monitoring is a dynamic and non-destructive testing technology. The advantages of ultrasonic guided wave monitoring for reinforcement corrosion are real-time, online and continuous. In addition, it can judge the different stages of steel bar corrosion, which achieved non-destructive detection.

  15. Influence of reinforcement and cemented parts on quality of radiological shields

    International Nuclear Information System (INIS)

    Ablewicz, Z.

    1974-01-01

    Results of studies of the influence of reinforcement density and shape of cemented parts on quality of radiological shields are presented. The studies were carried out on built shields and on experimental blocks. The experimental studies were aimed at determination of filling degree under cemented parts of different shapes using two kinds of cement normal and heavy one and at determination of filling degree of space with dense reinforcement as well as space near boarding. The influence of reinforcement density was studied using different spacing between bars and rows of bars. In the case of difficulties with good filling under the cemented parts so called ''beard'' and more liquid mixtures were used with success. (Z.M.)

  16. Analytical modeling of mixed-Mode bending behavior of asymmetric adhesively bonded pultruded GFRP joints

    Czech Academy of Sciences Publication Activity Database

    Ševčík, Martin; Shahverdi, M.; Hutař, Pavel; Vassilopoulos, Anastasios P.

    2015-01-01

    Roč. 147, OCT (2015), s. 228-242 ISSN 0013-7944 R&D Projects: GA MŠk(CZ) ED1.1.00/02.0068; GA MŠk(CZ) EE2.3.30.0063 Institutional support: RVO:68081723 Keywords : Mixed-Mode delamination * Asymmetric joint * Adhesively bonded joint * Failure criterion * Analytical prediction * GFRP Subject RIV: JL - Materials Fatigue, Friction Mechanics Impact factor: 2.024, year: 2015

  17. Exotic open-flavor $bc\\bar{q}\\bar{q}$, $bc\\bar{s}\\bar{s}$ and $qc\\bar{q}\\bar{b}$, $sc\\bar{s}\\bar{b}$ tetraquark states

    OpenAIRE

    Chen, Wei; Steele, T. G.; Zhu, Shi-Lin

    2013-01-01

    We study the exotic $bc\\bar{q}\\bar{q}$, $bc\\bar{s}\\bar{s}$ and $qc\\bar{q}\\bar{b}$, $sc\\bar{s}\\bar{b}$ systems by constructing the corresponding tetraquark currents with $J^P=0^+$ and $1^+$. After investigating the two-point correlation functions and the spectral densities, we perform QCD sum rule analysis and extract the masses of these open-flavor tetraquark states. Our results indicate that the masses of both the scalar and axial vector tetraquark states are about $7.1-7.2$ GeV for the $bc\\...

  18. In vitro study of transverse strength of fiber reinforced composites.

    Science.gov (United States)

    Mosharraf, R; Hashemi, Z; Torkan, S

    2011-01-01

    Reinforcement with fiber is an effective method for considerable improvement in flexural properties of indirect composite resin restorations. The aim of this in-vitro study was to compare the transverse strength of composite resin bars reinforced with pre-impregnated and non-impregnated fibers. Thirty six bar type composite resin specimens (3×2×25 mm) were constructed in three groups. The first group was the control group (C) without any fiber reinforcement. The specimens in the second group (P) were reinforced with pre-impregnated fibers and the third group (N) with non-impregnated fibers. These specimens were tested by the three-point bending method to measure primary transverse strength. Data were statistically analyzed with one way ANOVA and Tukey's tests. There was a significant difference among the mean primary transverse strength in the three groups (Ptransverse strength (Pstudy, it was concluded that reinforcement with fiber considerably increased the transverse strength of composite resin specimens, but impregnation of the fiber used implemented no significant difference in the transverse strength of composite resin samples.

  19. Strengthening and repairing of damaged concrete beams

    International Nuclear Information System (INIS)

    Mahmoud, M.K.; Ebrahiem, G.T.A.; Hassanein, S.A.

    2005-01-01

    The main part in this investigation is concerned with the advanced techniques of retrofitting damaged reinforced concrete (RC) beams. Glass fiber reinforced plastics (GFRP) were employed for this purpose. The aim of this paper is to investigate the advantage of using glass fiber .reinforced plastics (GFRP) to retrofit and repair damaged reinforced concrete beams. In this investigation, concrete beam specimens were preloaded up to the 60%, 70% arid 80% of their ultimate load capacity. The damaged beams were then repaired with one layer of FRP composite wraps and re-tested. Plastic reinforced by glass fibers 20% fiber volume fractions and with various fiber arrangement unidirectional, bi-directional and chopped were also considered. Four points bending test was adopted. The bending tests were performed on fourteen RC beams in addition to a two control, all of them were (225 30 15) cm in dimensions, and with a typical reinforcement details. Test results were indicative of the merit of using GFRP, as the ultimate loads were almost restored and the modes of failure were of ductile nature. Even more an increase in the ultimate bearing capacity was recorded for some of the retrofitted beams. The effects of the previously mentioned parameters on the cracking pattern and failure mode were reported and thoroughly discussed

  20. Rotation capacity of self-compacting steel fibre reinforced concrete beams

    NARCIS (Netherlands)

    Schumacher, P.; Walraven, J.C.; Den Uijl, J.A.; Bigaj-van Vliet, A.

    2009-01-01

    Steel fibres are known to enhance the toughness of concrete in compression and in tension. Steel fibres also improve the bond properties between concrete matrix and reinforcing steel bars. In order to investigate the effect of steel fibres on the rotation capacity of reinforced concrete members,

  1. Recycling of Reinforced Plastics

    Science.gov (United States)

    Adams, R. D.; Collins, Andrew; Cooper, Duncan; Wingfield-Digby, Mark; Watts-Farmer, Archibald; Laurence, Anna; Patel, Kayur; Stevens, Mark; Watkins, Rhodri

    2014-02-01

    This work has shown is that it is possible to recycle continuous and short fibre reinforced thermosetting resins while keeping almost the whole of the original material, both fibres and matrix, within the recyclate. By splitting, crushing hot or cold, and hot forming, it is possible to create a recyclable material, which we designate a Remat, which can then be used to remanufacture other shapes, examples of plates and tubes being demonstrated. Not only can remanufacturing be done, but it has been shown that over 50 % of the original mechanical properties, such as the E modulus, tensile strength, and interlaminar shear strength, can be retained. Four different forms of composite were investigated, a random mat Glass Fibre Reinforced Plastic (GFRP) bathroom component and boat hull, woven glass and carbon fibre cloth impregnated with an epoxy resin, and unidirectional carbon fibre pre-preg. One of the main factors found to affect composite recyclability was the type of resin matrix used in the composite. Thermoset resins tested were shown to have a temperature range around the Glass Transition Temperature (Tg) where they exhibit ductile behaviour, hence aiding reforming of the material. The high-grade carbon fibre prepreg was found to be less easy to recycle than the woven of random fibre laminates. One method of remanufacturing was by heating the Remat to above its glass transition temperature, bending it to shape, and then cooling it. However, unless precautions are taken, the geometric form may revert. This does not happen with the crushed material.

  2. Effect of GFRP spacer on local deformation of large superconductor in coil pack

    International Nuclear Information System (INIS)

    Nishimura, Arata; Tamura, Hitoshi; Mito, Toshiyuki; Yamamoto, Junya

    1994-01-01

    Design and construction of the Large Helical Device (LHD) are in progress at the National Institute for Fusion Science (NIFS) in Japan. The LHD has superconducting poloidal and helical coils, and many efforts have been undertaken to develop these large superconductors. When designing a large superconducting magnet, the mechanical behavior of the wound structure becomes a very important factor since the apparent rigidity affects the design of a coil support structure and the superconducting coil needs to endure the large electro-magnetic force it creates. Also, non-linear mechanical behavior should yield the instability of the magnet. In this paper, local deformation in a large conductor caused by GFRP spacers and epoxy adhesives was investigated after compressive rigidity testing. The epoxy adhesive used for attaching the GFRP spacers to the superconductor changed shape from an almost square sheet into a lens-like sheet during deformation, and a dent appeared on the surface of the superconductor. Three-dimensional FEM analysis showed that a compressive stress in the vertical direction of the loading axis existed in the adhesive plane. This stress component makes the adhesive lens-like and it results in the dent created during the compressive testing. This local deformation should yield a part of the permanent deformation observed after the compressive load cycle at 4.2 K

  3. Flexible concrete link slabs used as expansion joints in bridge decks

    DEFF Research Database (Denmark)

    Lárusson, Lárus Helgi; Fischer, Gregor

    2011-01-01

    of water through the expansion joint and subsequent corrosion of girders and girder bearings. Investigations on joint-less superstructures using conventional steel reinforcement in so-called concrete link slabs indicate improved performance and economic feasibility. However, this concept requires...... relatively large amounts of steel reinforcement for crack control purposes and consequently provides a relatively large flexural stiffness and negative moment capacity at the joint between the spans. These contradicting requirements and effects in existing replacement concepts for damaged mechanical bridge...... joints are currently unresolved. In the proposed system described in this paper, a ductile cement-based composite section reinforced with Glass Fiber Reinforced Polymers (GFRP) replaces the damaged expansion joint. The combination of this ductile concrete together with corrosion resistant GFRP...

  4. Photoelastic analysis of mandibular full-arch implant-supported fixed dentures made with different bar materials and manufacturing techniques.

    Science.gov (United States)

    Zaparolli, Danilo; Peixoto, Raniel Fernandes; Pupim, Denise; Macedo, Ana Paula; Toniollo, Marcelo Bighetti; Mattos, Maria da Glória Chiarello de

    2017-12-01

    To compare the stress distribution of mandibular full dentures supported with implants according to the bar materials and manufacturing techniques using a qualitative photoelastic analysis. An acrylic master model simulating the mandibular arch was fabricated with four Morse taper implant analogs of 4.5×6mm. Four different bars were manufactured according to different material and techniques: fiber-reinforced resin (G1, Trinia, CAD/CAM), commercially pure titanium (G2, cpTi, CAD/CAM), cobalt‑chromium (G3, Co-Cr, CAD/CAM) and cobalt‑chromium (G4, Co-Cr, conventional cast). Standard clinical and laboratory procedures were used by an experienced dental technician to fabricate 4 mandibular implant-supported dentures. The photoelastic model was created based on the acrylic master model. A load simulation (150N) was performed in total occlusion against the antagonist. Dentures with fiber-reinforced resin bar (G1) exhibited better stress distribution. Dentures with machined Co-Cr bar (G3) exhibited the worst standard of stress distribution, with an overload on the distal part of the posteriors implants, followed by dentures with cast Co-Cr bar (G4) and machined cpTi bar (G2). The fiber-reinforced resin bar exhibited an adequate stress distribution and can serve as a viable alternative for oral rehabilitation with mandibular full dentures supported with implants. Moreover, the use of the G1 group offered advantages including reduced weight and less possible overload to the implants components, leading to the preservation of the support structure. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Pitting Corrosion Behaviour of New Corrosion-Resistant Reinforcement Bars in Chloride-Containing Concrete Pore Solution.

    Science.gov (United States)

    Jiang, Jin-Yang; Liu, Yao; Chu, Hong-Yan; Wang, Danqian; Ma, Han; Sun, Wei

    2017-08-04

    In this study, the pitting behaviour of a new corrosion-resistant alloy steel (CR) is compared to that of low-carbon steel (LC) in a simulated concrete pore solution with a chloride concentration of 5 mol/L. The electrochemical behaviour of the bars was characterised using linear polarisation resistance (LPR) and electrochemical impedance spectroscopy (EIS). The pitting profiles were detected by reflective digital holographic microscopy (DHM), scanning electron microscopy (SEM), and the chemical components produced in the pitting process were analysed by X-ray energy dispersive spectroscopy (EDS). The results show that the CR bars have a higher resistance to pitting corrosion than the LC bars. This is primarily because of the periodic occurrence of metastable pitting during pitting development. Compared to the pitting process in the LC bars, the pitting depth grows slowly in the CR bars, which greatly reduces the risk of pitting. The possible reason for this result is that the capability of the CR bars to heal the passivation film helps to restore the metastable pits to the passivation state.

  6. Evaluation of the cryogenic mechanical properties of the insulation material for ITER Feeder superconducting joint

    Science.gov (United States)

    Wu, Zhixiong; Huang, Rongjin; Huang, ChuanJun; Yang, Yanfang; Huang, Xiongyi; Li, Laifeng

    2017-12-01

    The Glass-fiber reinforced plastic (GFRP) fabricated by the vacuum bag process was selected as the high voltage electrical insulation and mechanical support for the superconducting joints and the current leads for the ITER Feeder system. To evaluate the cryogenic mechanical properties of the GFRP, the mechanical properties such as the short beam strength (SBS), the tensile strength and the fatigue fracture strength after 30,000 cycles, were measured at 77K in this study. The results demonstrated that the GFRP met the design requirements of ITER.

  7. Interfacial degradation of organic composite material by irradiation in reactor

    Energy Technology Data Exchange (ETDEWEB)

    Nishijima, Shigehiro; Nishiura, Tetsuya; Okada, Toichi [Osaka Univ., Ibaraki (Japan). Inst. of Scientific and Industrial Research

    1996-04-01

    Glass fiber reinforced plastics (GFRP) with many kinds of matrix resins were made of E glass treated with silane as the reinforced material. Degradation of shearing strength of GFRP irradiated at low temperature was determined. It was clear from the results of comparing the degradation process with the fractured surface that the degradation was very affected by the radiation resistance of the bonded part between resin and coupling agents. It means that we had to be careful in the choice of interfacial treatments and epoxy matrices corresponded to it. (S.Y.)

  8. Corrosion resistance and development length of steel reinforcement with cementitious coatings

    Science.gov (United States)

    Pei, Xiaofei

    This research program focused on the corrosion resistance and development length of reinforcing steel coated with Cementitious Capillary Crystalline Waterproofing (CCCW) materials. The first part of this research program involved using the half-cell potential method to evaluate the corrosion resistance of CCCW coating materials. One hundred and two steel bars were embedded in concrete cylinders and monitored. In total, 64 steel reinforcing bars were coated with CCCW prior to embedment, 16 mortar cylinders were externally coated with CCCW, and 22 control (uncoated) samples were tested. All the samples were immersed in a 3.5% concentration chloride solution for a period of one year. Three coating types were studied: CCCW-B, CCCW-B+ C and CCCW-C+D. The test results showed that the CCCW coating materials delayed the corrosion activity to varying degrees. In particular, CCCW-C+D applied on the reinforcing steel surface dramatically delayed the corrosion activity when compared to the control samples. After being exposed to the chloride solution for a period of one year, no sign of corrosion was observed for the cylinders where the concrete surface was coated. The second part of this research evaluated the bond strength and development length of reinforcing steel coated with two types of CCCW coating materials (CCCW-B+C and CCCW-C+D) using a modified pull-out test method. A self-reacting inverted T-shaped beam was designed to avoid compression in the concrete surrounding the reinforcing steel. Steel reinforcing bars were embedded along the web portion of the T-beam with various embedded lengths and were staggered side by side. In total, six T-beams were fabricated and each beam contained 8 samples. Both short-term (7 days) and long-term (3 months) effects of water curing were evaluated. The reinforcing steel bars coated with CCCW-B+C demonstrated a higher bond strength than did samples coated with CCCW-C+D. However, the bond strengths of samples with coating materials

  9. Studies on connecting structure between steel shell and steel reinforced concrete; Kokaku to tekkotsu tekkin concrete tono ketsugo kozo ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Morimoto, A. [Kinki University, Osaka (Japan). Faculty of Science and Engineering; Morikawa, H.; Ito, N. [Metropolitan Expressway Public Corp., Tokyo (Japan)

    1996-02-15

    On the insert reinforcing bar structure for the connecting part of the main tower of cable stayed bridges, this paper reports verification results on a load resistant safety with a full-scale model, structure analysis and construction work. The basic structure was composed of a drilled steel shell, inserted reinforcing bars, fixing structure of bars in lining concrete of the shell and a pressure bearing plate. As an experimental result, the connecting part had a sufficient load carrying capacity against both tensile and compressive loads. The shear stress of the insert reinforcing bar structure was estimated successfully under von Mises`s condition. The shear spring constant in deformation characteristics was linearly proportional to an inserted reinforcing bar ratio. In earthquake, nearly 60% of an allowable compressive load was transferred to concrete through the pressure bearing plate. The analytical results of load resistant deformation characteristics of the connecting part well agreed with experimental ones, and the proposed analytical model was applicable to estimation of a dynamic behavior. 5 refs., 22 figs., 4 tabs.

  10. CO2-laser-assisted processing of glass fiber-reinforced thermoplastic composites

    Science.gov (United States)

    Brecher, Christian; Emonts, Michael; Schares, Richard Ludwig; Stimpfl, Joffrey

    2013-02-01

    To fully exploit the potential of fiber-reinforced thermoplastic composites (FRTC) and to achieve a broad industrial application, automated manufacturing systems are crucial. Investigations at Fraunhofer IPT have proven that the use of laser system technology in processing FRTC allows to achieve high throughput, quality, flexibility, reproducibility and out-of-autoclave processing simultaneously. As 90% of the FRP in Europe1 are glass fiber-reinforced a high impact can be achieved by introducing laser-assisted processing with all its benefits to glass fiber-reinforced thermoplastics (GFRTC). Fraunhofer IPT has developed the diode laser-assisted tape placement (laying and winding) to process carbon fiber-reinforced thermoplastic composites (CFRTC) for years. However, this technology cannot be transferred unchanged to process milky transparent GFRTC prepregs (preimpregnated fibers). Due to the short wavelength (approx. 980 nm) and therefore high transmission less than 20% of the diode laser energy is absorbed as heat into non-colored GFRTC prepregs. Hence, the use of a different wave length, e.g. CO2-laser (10.6 μm) with more than 90% laser absorption, is required to allow the full potential of laser-assisted processing of GFRTC. Also the absorption of CO2-laser radiation at the surface compared to volume absorption of diode laser radiation is beneficial for the interlaminar joining of GFRTC. Fraunhofer IPT is currently developing and investigating the CO2-laser-assisted tape placement including new system, beam guiding, process and monitoring technology to enable a resource and energy efficient mass production of GFRP composites, e.g. pipes, tanks, masts. The successful processing of non-colored glass fiber-reinforced Polypropylene (PP) and Polyphenylene Sulfide (PPS) has already been proven.

  11. Determination of mechanical properties of some glass fiber reinforced plastics suitable to Wind Turbine Blade construction

    Science.gov (United States)

    Steigmann, R.; Savin, A.; Goanta, V.; Barsanescu, P. D.; Leitoiu, B.; Iftimie, N.; Stanciu, M. D.; Curtu, I.

    2016-08-01

    The control of wind turbine's components is very rigorous, while the tower and gearbox have more possibility for revision and repairing, the rotor blades, once they are deteriorated, the defects can rapidly propagate, producing failure, and the damages can affect large regions around the wind turbine. This paper presents the test results, performed on glass fiber reinforced plastics (GFRP) suitable to construction of wind turbine blades (WTB). The Young modulus, shear modulus, Poisson's ratio, ultimate stress have been determined using tensile and shear tests. Using Dynamical Mechanical Analysis (DMA), the activation energy for transitions that appear in polyester matrix as well as the complex elastic modulus can be determined, function of temperature.

  12. Effect of the Volume Fraction of Jute Fiber on the Interlaminar Shear Stress and Tensile Behavior Characteristics of Hybrid Glass/Jute Fiber Reinforced Polymer Composite Bar for Concrete Structures

    Directory of Open Access Journals (Sweden)

    Chan-Gi Park

    2016-01-01

    Full Text Available Hybrid glass/jute fiber reinforced polymer (HGJFRP composite bars were manufactured for concrete structures, and their interlaminar shear stress and tensile performance were evaluated. HGJFRP composite bars were manufactured using a combination of pultrusion and braiding processes. Jute fiber was surface-treated with a silane coupling agent. The mixing ratio of the fiber to the vinyl ester used in the HGJFRP composite bars was 7 : 3. Jute fiber was used to replace glass fiber in proportions of 0, 30, 50, 70, and 100%. The interlaminar shear stress decreased as the proportion of jute fiber increased. Fractures appeared due to delamination between the surface-treated component and the main part of the HGJFRP composite bar. Tensile load-strain curves with 50% jute fiber exhibited linear behavior. With a jute fiber volume fraction of 70%, some plastic deformation occurred. A jute fiber mixing ratio of 100% resulted in a display of linear elastic brittle behavior from the fiber; however, when the surface of the fiber was coated with poly(vinyl acetate, following failure, the jute fiber exhibited partial load resistance. The tensile strength decreased as the jute fiber content increased; however, the tensile strength did not vary linearly with jute fiber content.

  13. Geometry effect on the behaviour of single and glue-laminated glass fibre reinforced polymer composite sandwich beams loaded in four-point bending

    International Nuclear Information System (INIS)

    Awad, Ziad K.; Aravinthan, Thiru; Manalo, Allan

    2012-01-01

    Highlights: ► Investigated the behaviour of single and glue-laminated GFRP sandwich beam. ► Effect of shear span to depth was a key factor affecting the overall behaviour. ► Comparison with prediction models gave reasonable results in specific regions. ► A failure map was developed to identify the shear and flexural failures of panels. -- Abstract: The research investigated the behaviour of single and glue laminated glass fibre reinforced polymer (GFRP) composite sandwich beams considering different spans and beam cross sections. The composite sandwich beams with different thicknesses (1, 2, 3, 4, and 5 sandwich layers) have been tested in four-point static flexural test with different shear span to depth ratio (a/d). The a/d ratios showed a direct effect on the flexural and shear behaviour. The capacity of the beam decreased with increasing a/d. Various failure modes were observed including core crushing, core shear, and top skin compression failure. The failure mode map developed based on the experimental finding and analytical prediction indicated that the failure mode is affected by the a/d with the number of glue laminated panels.

  14. Load carrying capacity of keyed joints reinforced with high strength wire rope loops

    OpenAIRE

    Jørgensen, Henrik B.; Hoang, Linh Cao

    2015-01-01

    Vertical shear connections between precast concrete wall elements are usually made as keyed joints reinforced with overlapping U-bars. The overlapping U-bars form a cylindrical core in which the locking bar is placed and the connection is subsequently grouted with mortar. A more construction friendly shear connection can be obtained by replacing the U-bars with high strength looped wire ropes. The wire ropes have the advantage of being flexible (they have virtually no bending stiffness) which...

  15. Flexural behavior of concrete beam with mechanical splices of reinforcement subjected to cyclic loading

    International Nuclear Information System (INIS)

    Nab, H. S.; Kim, W. B.

    2008-01-01

    In nuclear power plant structures, the mechanical rebar splices are designated and constructed on the basis of ACI and ASME code. Regardless of good performance on mechanical rebar splices, these splicing methods that did not be registered on ASME code have not restricted to apply to construction site. In this study, the main candidate splice is cold roll formed parallel threaded splice. This was registered newly in ASME Section III division 2 CC 4333 'Mechanical Splices' in 2004. To compare the traditional rebar splice with mechanical rebar splices, concrete beams were made to evaluate the ductility of spliced reinforcing bars. Based on Experimental results, it was identified that the mechanical rebar splices by parallel threaded coupler had better accumulated dissipation energy capacity to resist seismic behavior than the traditional lapping splices. It showed that concrete specimens with D36 reinforcing bar coupler are 1.8 times better performance and that concrete specimens with D22 reinforcing bar coupler are 2.8 times better performance. (authors)

  16. Self-diagnosis of structures strengthened with hybrid carbon-fiber-reinforced polymer sheets

    Science.gov (United States)

    Wu, Z. S.; Yang, C. Q.; Harada, T.; Ye, L. P.

    2005-06-01

    The correlation of mechanical and electrical properties of concrete beams strengthened with hybrid carbon-fiber-reinforced polymer (HCFRP) sheets is studied in this paper. Two types of concrete beams, with and without reinforcing bars, are strengthened with externally bonded HCFRP sheets, which have a self-structural health monitoring function due to the electrical conduction and piezoresistivity of carbon fibers. Parameters investigated include the volume fractions and types of carbon fibers. According to the investigation, it is found that the hybridization of uniaxial HCFRP sheets with several different types of carbon fibers is a viable method for enhancing the mechanical properties and obtaining a built-in damage detection function for concrete structures. The changes in electrical resistance during low strain ranges before the rupture of carbon fibers are generally smaller than 1%. Nevertheless, after the gradual ruptures of carbon fibers, the electrical resistance increases remarkably with the strain in a step-wise manner. For the specimens without reinforcing bars, the electrical behaviors are not stable, especially during the low strain ranges. However, the electrical behaviors of the specimens with reinforcing bars are relatively stable, and the whole range of self-sensing function of the HCFRP-strengthened RC structures has realized the conceptual design of the HCFRP sensing models and is confirmed by the experimental investigations. The relationships between the strain/load and the change in electrical resistance show the potential self-monitoring capacity of HCFRP reinforcements used for strengthening concrete structures.

  17. Strengthening of the Timber Members Using Fibre Reinforced Polymer Composites

    Directory of Open Access Journals (Sweden)

    Ioana-Sorina Enţuc

    2004-01-01

    Full Text Available The reinforcement of structural wood products has become in the last decades an efficient method of improving structural capabilities of load carrying members made of this material. Some important steps in earlier stages of research were focused on using metallic reinforcement, including steel bars, prestressed stranded cables, and bonded steel and aluminum plates. A disadvantage of the metallic reinforcement was the poor compatibility between the wood and the reinforcing materials. In comparison with metallic reinforcement, fiber reinforced polymers (FRP composites are compatible with structural wood products leading to efficient hybrid members. Some interesting strengthening alternatives using FRP applied to wood beams and to wood columns are presented in this paper.

  18. The meaning of transit times in NDT of reinforced concrete

    International Nuclear Information System (INIS)

    Suarez Antola, R.

    2007-10-01

    Transit times of longitudinal pulses that travel near reinforcing steel bars are usually smaller than in plain concrete. Chung first, and then Bungey, demonstrated the importance of including bar diameters in the correction factors when pulses propagating parallel and near to the bars can not be avoided. Besides the influence of geometric dispersion and mode conversion on pulse propagation, there is an effect due to a specific pattern of radial variation of longitudinal wave velocities from the surface of the embedded steel bar. Wall effects produce a region (a sheath) of concrete surrounding the steel bar, with smaller longitudinal pulse velocities in comparison with the velocity farther away from the bar. Then the acoustics energy travels trapped in a kind of composite leaky waveguide with a velocity less than the compression (P) wave velocity in steel and in concrete but greater than the extensional wave velocity in steel. A mathematical model of the propagation of a longitudinal wave-packet is constructed, taking into account both attenuation and dispersion effects. An asymptotic analysis of pulse propagation and the introduction of a threshold of detection in the receiving transducer, allows the derivation of an approximate analytical formula for transit times. Then the meaning of transit times in NDT of concrete is discussed. The above mentioned formula is used to study the effects of the reinforcing bar radius, the propagation parameters in plain concrete and in the sheath surrounding the steel bar, the path length between the transmitting and the receiving transducers, and the energy and the spectral composition of the pulse injected by the emitter in the tested body. Chung s empirical correlation between the measured pulse velocity and bar radius is reviewed and a new correlation is proposed

  19. Steel fiber reinforced concrete

    International Nuclear Information System (INIS)

    Baloch, S.U.

    2005-01-01

    Steel-Fiber Reinforced Concrete is constructed by adding short fibers of small cross-sectional size .to the fresh concrete. These fibers reinforce the concrete in all directions, as they are randomly oriented. The improved mechanical properties of concrete include ductility, impact-resistance, compressive, tensile and flexural strength and abrasion-resistance. These uniqlte properties of the fiber- reinforcement can be exploited to great advantage in concrete structural members containing both conventional bar-reinforcement and steel fibers. The improvements in mechanical properties of cementitious materials resulting from steel-fiber reinforcement depend on the type, geometry, volume fraction and material-properties of fibers, the matrix mix proportions and the fiber-matrix interfacial bond characteristics. Effects of steel fibers on the mechanical properties of concrete have been investigated in this paper through a comprehensive testing-programme, by varying the fiber volume fraction and the aspect-ratio (Lid) of fibers. Significant improvements are observed in compressive, tensile, flexural strength and impact-resistance of concrete, accompanied by marked improvement in ductility. optimum fiber-volume fraction and aspect-ratio of steel fibers is identified. Test results are analyzed in details and relevant conclusions drawn. The research is finally concluded with future research needs. (author)

  20. Connections in Precast Buildings using Ultra High-Strength Fibre Reinforced Concrete

    DEFF Research Database (Denmark)

    Hansen, Lars Pilegaard

    1995-01-01

    Ultra high-strength concrete adds new dimensions to the design of concrete structures. It is a brittle material but introducing fibres into the matrix changes the material into a highly ductile material. Furthermore, the fibre reinforcement increases the anchorage of traditional reinforcement bar...... and the fire resistance. Such a fibre reinforced ultra high-strength material has been used to develop a simple joint solution between slab elements in a column - slab building system....

  1. Time-Dependent Behavior of Reinforced Polymer Concrete Columns under Eccentric Axial Loading

    Directory of Open Access Journals (Sweden)

    Valentino Paolo Berardi

    2012-11-01

    Full Text Available Polymer concretes (PCs represent a promising alternative to traditional cementitious materials in the field of new construction. In fact, PCs exhibit high compressive strength and ultimate compressive strain values, as well as good chemical resistance. Within the context of these benefits, this paper presents a study on the time-dependent behavior of polymer concrete columns reinforced with different bar types using a mechanical model recently developed by the authors. Balanced internal reinforcements are considered (i.e., two bars at both the top and bottom of the cross-section. The investigation highlights relevant stress and strain variations over time and, consequently, the emergence of a significant decrease in concrete’s stiffness and strength over time. Therefore, the results indicate that deferred effects due to viscous flow may significantly affect the reliability of reinforced polymer concrete elements over time.

  2. Superelastic SMA–FRP composite reinforcement for concrete structures

    International Nuclear Information System (INIS)

    Wierschem, Nicholas; Andrawes, Bassem

    2010-01-01

    For many years there has been interest in using fiber-reinforced polymers (FRPs) as reinforcement in concrete structures. Unfortunately, due to their linear elastic behavior, FRP reinforcing bars are never considered for structural damping or dynamic applications. With the aim of improving the ductility and damping capability of concrete structures reinforced with FRP reinforcement, this paper studies the application of SMA–FRP, a relatively novel type of composite reinforced with superelastic shape memory alloy (SMA) wires. The cyclic tensile behavior of SMA–FRP composites are studied experimentally and analytically. Tests of SMA–FRP composite coupons are conducted to determine their constitutive behavior. The experimental results are used to develop and calibrate a uniaxial SMA–FRP analytical model. Parametric and case studies are performed to determine the efficacy of the SMA–FRP reinforcement in concrete structures and the key factors governing its behavior. The results show significant potential for SMA–FRP reinforcement to improve the ductility and damping of concrete structures while still maintaining its elastic characteristic, typical of FRP reinforcement

  3. Transporting fibres as reinforcement in self-compacting concrete

    NARCIS (Netherlands)

    Grünewald, S.; Walraven, J.C.

    2009-01-01

    The development of self-compacting concrete (SCC) was an important step towards efficiency at building sites, rationally producing prefabricated concrete elements, better working conditions and improved quality and appearance of concrete structures. By adding fibres to SCC bar reinforcement can be

  4. High strength reinforcing steel bars : concrete shear friction interface : final report : Part A.

    Science.gov (United States)

    2017-03-01

    High-strength steel (HSS) reinforcement, specifically ASTM A706 Grade 80 (550), is now permitted by the AASHTO LRFD Bridge Design Specifications for use in reinforced concrete bridge components in non-seismic regions. Using Grade 80 (550) steel reinf...

  5. The influence of the damaged reinforcing bars on the stress-strain state of the rein-forced concrete beams

    Directory of Open Access Journals (Sweden)

    Zenoviy Blikharskyy

    2017-04-01

    Full Text Available The article is devoted to the overall view of experimental research of reinforced concrete beams with the simultaneous influence of the corrosion environment and loading. The tests have been carried out upon the reinforced concrete specimens considering the corrosion in the acid environment, namely 10 % H2SO4 that have been taken as a model of the aggressive environment. The beams are with span equalling to 1,9m with different series of tensile armature, concrete compressive strength and different length of impact of corrosion (continuous and local. The influence of simultaneous action of the aggressive environment and loading on strength of reinforced-concrete beams has been described. For a detailed study of the effect of individual components there was suggested additional experimental modelling of the only tensile armature damage without concrete damage. It will investigate the influence of this factor irrespective of the concrete.

  6. Determination of Bond Capacity in Reinforced Concrete Beam and Its Influence on the Flexural Strength

    Directory of Open Access Journals (Sweden)

    Mohammad Rashidi

    2016-05-01

    Full Text Available This paper presents results of an experimental investigation of actual performance of the reinforced concrete beam in bond under flexure, when reinforced with tension steel is going to consider. In this experiment four specimens of beam and a bar in the middle of the width of the beam has been used and 2.5 cm of concrete cover has been considered from the center of the bar. In addition, transverse bars have been used to reassure lack of shear yield at the two ends of the beam. Flexural bar has been put in the middle of the beam symmetrically and the length of the flexural bar in each of the samples shall be: 15, 20, 30 and 40 cm. Three cylindrical samples were made in order to determine f’c and were examined at 28 days and the compressive strength of concrete used in this study was about 35 MPa. The beam samples were examined after 28 days via two-point loading system. Based on the results, increasing the length of bar causes increase of flexural strength. The presence of longitudinal rebar resulted in the ultimate momentum to be more than the crack momentum of the cross-section in parts which have broken at the point of longitudinal bar cut.

  7. Experimental analysis of reinforced concrete columns strengthened with Self-Compacting concrete

    Directory of Open Access Journals (Sweden)

    M. Y. M. Omar

    Full Text Available This paper presents the results of reinforced concrete columns strengthened by addition of a self-compacting concrete overlay at the compressed and at the tensioned face of the member, with and without addition of longitudinal steel bars. Eight columns were submit- ted to loading with an initial eccentricity of 60 mm . These columns had 120 mm x 250 mm of rectangular cross section, 2000 mm in length and four longitudinal reinforcement steel bars with 10 mm in diameter. Reference columns P1 and P2 were tested to failure without any type of rehabilitation. Columns P3 to P8 were loaded to a predefined load (close to the initial yield point of tension reinforce- ment, then unloaded and strengthened for a subsequent test until failure. Results showed that the method of rehabilitation used was effective, increasing the loading capacity of the strengthened pieces by 2 to 5 times the ultimate load of the reference column.

  8. A Preliminary Study on Cathodic Prevention in Reinforced Mortar

    NARCIS (Netherlands)

    Koleva, D.A.; Van Breugel, K.; Mol, J.M.C.; De Wit, J.H.W.

    2010-01-01

    This work presents the preliminary tests on the performance of cathodic prevention (CPre) in reinforced mortar, subjected to aggressive (10% NaCl environment). Cathodic prevention is an electrochemical technique for minimizing, actually "preventing" any eventual corrosion of the steel bars in

  9. Strain rate effects on reinforcing steels in tension

    Science.gov (United States)

    Cadoni, Ezio; Forni, Daniele

    2015-09-01

    It is unquestionable the fact that a structural system should be able to fulfil the function for which it was created, without being damaged to an extent disproportionate to the cause of damage. In addition, it is an undeniable fact that in reinforced concrete structures under severe dynamic loadings, both concrete and reinforcing bars are subjected to high strain-rates. Although the behavior of the reinforcing steel under high strain rates is of capital importance in the structural assessment under the abovementioned conditions, only the behaviour of concrete has been widely studied. Due to this lack of data on the reinforcing steel under high strain rates, an experimental program on rebar reinforcing steels under high strain rates in tension is running at the DynaMat Laboratory. In this paper a comparison of the behaviour in a wide range of strain-rates of several types of reinforcing steel in tension is presented. Three reinforcing steels, commonly proposed by the European Standards, are compared: B500A, B500B and B500C. Lastly, an evaluation of the most common constitutive laws is performed.

  10. Numerical simulation of the throwing power of cathodic prevention applied to marine reinforced concrete piles by means of sacrificial anodes

    Energy Technology Data Exchange (ETDEWEB)

    Bertolini, Luca; Redaelli, Elena [Politecnico di Milano, Dipartimento di Chimica, Materiali e Ingegneria Chimica ' G. Natta' , Via Mancinelli, 7, 20131 Milan (Italy)

    2004-07-01

    The paper deals with the determination of current and potential distribution in reinforced concrete elements partially submerged in seawater aimed at predicting the throwing power of cathodic prevention applied by means of sacrificial anodes. Previous laboratory studies carried out on reinforced concrete columns 15 cm x 15 cm x 120 cm showed that the use of sacrificial anodes placed in the solution at the bottom of the column could provide protection of corroding steel bars in the emerged part of the pile up to about 60 cm from the water level. However, if sacrificial anodes were applied when the concrete was chloride free and steel bars were still passive, even the highest bar, placed at 1 m from the level of water, was protected. This is due to the higher polarizability of passive steel, that makes the throwing power of cathodic prevention higher compared to that of cathodic protection. In order to extend the results obtained on small-scale specimens to elements of higher dimensions, numerical simulations of current and potential distribution were carried out. Two-dimensional models were set up of reinforced concrete piles containing steel bars at different heights protected with sacrificial anodes placed in the water in which they were partially submerged. Boundary conditions describing the electrochemical behaviour of bars were obtained from polarisation curves measured on the previously mentioned columns. Values of concrete conductivity at different heights from the water level were also obtained from those tests. Several cases were considered, representative of conditions differing in electrochemical behaviour of steel bars, dimensions of element, position of sacrificial anodes. The paper discusses the results obtained from the models and compares them in terms of the throwing power that can be reached by using sacrificial anodes immersed in the seawater to protect reinforcing steel bars in the emerged part of a pile. (authors)

  11. An Experimental Study of a Midbroken 2-Bay 6-Storey Reinforced Concrete Frame subject to Earthquakes

    DEFF Research Database (Denmark)

    Skjærbæk, P. S.; Taskin, B.; Kirkegaard, Poul Henning

    1997-01-01

    A 2-bay, 6-storey model test reinforced concrete frame (scale 1:5) subjected to sequential earthquakes of increasing magnitude is considered in this paper. The frame was designed with a weak storey, in which the columns are weakened by using thinner and weaker reinforcement bars. The aim of the w......A 2-bay, 6-storey model test reinforced concrete frame (scale 1:5) subjected to sequential earthquakes of increasing magnitude is considered in this paper. The frame was designed with a weak storey, in which the columns are weakened by using thinner and weaker reinforcement bars. The aim...... of the work is to study global response to a damaging strong motion earthquake event of such buildings. Special emphasis is put on examining to what extent damage in the weak storey can be identified from global response measurements during an earthquake where the structure survives, and what level...

  12. Calculation of load-bearing capacity of prestressed reinforced concrete trusses by the finite element method

    Science.gov (United States)

    Agapov, Vladimir; Golovanov, Roman; Aidemirov, Kurban

    2017-10-01

    The technique of calculation of prestressed reinforced concrete trusses with taking into account geometrical and physical nonlinearity is considered. As a tool for solving the problem, the finite element method has been chosen. Basic design equations and methods for their solution are given. It is assumed that there are both a prestressed and nonprestressed reinforcement in the bars of the trusses. The prestress is modeled by setting the temperature effect on the reinforcement. The ways of taking into account the physical and geometrical nonlinearity for bars of reinforced concrete trusses are considered. An example of the analysis of a flat truss is given and the behavior of the truss on various stages of its loading up to destruction is analyzed. A program for the analysis of flat and spatial concrete trusses taking into account the nonlinear deformation is developed. The program is adapted to the computational complex PRINS. As a part of this complex it is available to a wide range of engineering, scientific and technical workers

  13. Structural behavior of reinforced concrete structures at high temperatures

    International Nuclear Information System (INIS)

    Yamazaki, N.; Yamazaki, M.; Mochida, T.; Mutoh, A.; Miyashita, T.; Ueda, M.; Hasegawa, T.; Sugiyama, K.; Hirakawa, K.; Kikuchi, R.; Hiramoto, M.; Saito, K.

    1995-01-01

    To establish a method to predict the behavior of reinforced concrete structures subjected simultaneously to high temperatures and external loads, this paper presents the results obtained in several series of tests carried out recently in Japan. This paper reports on the material properties of concrete and steel bars under high temperatures. It also considers the heat transfer properties of thick concrete walls under transient high temperatures, and the structural behavior of reinforced concrete beams subjected to high temperatures. In the tests, data up to 800 C were obtained for use in developing a computational method to estimate the non-linear behavior of reinforced concrete structures exposed to high temperatures. (orig.)

  14. Alternative method of manufacture and assembly of concrete reinforcement for cylindrical part of containment

    International Nuclear Information System (INIS)

    Chalus, Z.

    1982-01-01

    The problems are discussed of the reinforcement for the cylindrical part of the containment of the standard WWER 1000 nuclear power plant in the Temelin locality. Soviet 25 G 2 S bars 40 mm in diameter and Czechoslovak bars 39 mm in diameter of steels 10 216 and 10 425 are to be used. The possible technologies of laying are presented and as an alternative solution the concept of reinforcing cages is discussed. The production of cages is considered as an on-site project. The cages would be manufactured using horizontal or vertical fixtures and stored vertically close together in special stands. Labour consumption for the production of both types of reinforcing cages is discussed and a survey presented of the necessary equipment when using the alternative technologies. Labour consumption for the assembly of the cages is also given, this for the variant when the reinforcement is fixed to the assembled steel lining, i.e., either cages 12 by 12 m in dimension (inner, outer, including transverse reinforcement) or as spatial components, baskets, with regard to the possibility of transporting elements 3 by 12 m in dimension. (B.S.)

  15. Corrosion Measurements in Reinforced Fly Ash Concrete Containing Steel Fibres Using Strain Gauge Technique

    Directory of Open Access Journals (Sweden)

    V. M. Sounthararajan

    2013-01-01

    Full Text Available Corrosion of steel bars in concrete is a serious problem leading to phenomenal volume expansion and thereby leading to cover concrete spalling. It is well known that the reinforced concrete structures subjected to chloride attack during its service life cause these detrimental effects. The early detection of this damage potential can extend the service life of concrete. This study reports the comprehensive experimental studies conducted on the identification of corrosion mechanism in different types of reinforced concrete containing class-F fly ash and hooked steel fibres. Fly ash replaced concrete mixes were prepared with 25% and 50% fly ash containing steel fibres at 0.5%, 1.0%, and 1.5% by volume fraction. Corrosion process was investigated in an embedded steel bar (8 mm diameter reinforced in concrete by passing an impressed current in sodium chloride solution. Strain gauge attached to the rebars was monitored for electrical measurements using strain conditioner. Strain gauge readings observed during the corrosion process exhibited the volume changes of the reinforcement embedded inside the concrete. The corrosion potential of different steel fibre reinforced concrete mixes with fly ash addition showed higher resistance towards the corrosion initiation.

  16. Experimental determinations of the eigenmodes for composite bars made with carbon and Kevlar-carbon fibers

    Science.gov (United States)

    Miriţoiu, C. M.; Stănescu, M. M.; Burada, C. O.; Bolcu, D.; Roşca, V.

    2015-11-01

    For modal identification, the single-point excitation method has been widely used in modal tests and it consists in applying a force in a given point and recording the vibratory structure response in all interest points, including the excitation point. There will be presented the experimental recordings for the studied bars (with Kevlar-carbon or carbon fibers), the frequency response function in Cartesian and polar coordinates. By using the frequency response functions we determine the eigenparameters for each bar. We present the final panel of the eigenmodes (with the damping factors, eigenfrequencies and critical damping) for each considered bar. Using the eigenfrequency of the first determined eigenmode, the bars stiffness has been determined. The presented bars can be used in practical engineering for: car or bus body parts, planes body parts, bullet-proof vests, reinforcements for sandwich beams, and so on.

  17. Bar dimensions and bar shapes in estuaries

    Science.gov (United States)

    Leuven, Jasper; Kleinhans, Maarten; Weisscher, Steven; van der Vegt, Maarten

    2016-04-01

    Estuaries cause fascinating patterns of dynamic channels and shoals. Intertidal sandbars are valuable habitats, whilst channels provide access to harbors. We still lack a full explanation and classification scheme for the shapes and dimensions of bar patterns in natural estuaries, in contrast with bars in rivers. Analytical physics-based models suggest that bar length in estuaries increases with flow velocity, tidal excursion length or estuary width, depending on which model. However, these hypotheses were never validated for lack of data and experiments. We present a large dataset and determine the controls on bar shape and dimensions in estuaries, spanning bar lengths from centimeters (experiments) to 10s of kilometers length. First, we visually identified and classified 190 bars, measured their dimensions (width, length, height) and local braiding index. Data on estuarine geometry and tidal characteristics were obtained from governmental databases and literature on case studies. We found that many complex bars can be seen as simple elongated bars partly cut by mutually evasive ebb- and flood-dominated channels. Data analysis shows that bar dimensions scale with estuary dimensions, in particular estuary width. Breaking up the complex bars in simple bars greatly reduced scatter. Analytical bar theory overpredicts bar dimensions by an order of magnitude in case of small estuarine systems. Likewise, braiding index depends on local width-to-depth ratio, as was previously found for river systems. Our results suggest that estuary dimensions determine the order of magnitude of bar dimensions, while tidal characteristics modify this. We will continue to model bars numerically and experimentally. Our dataset on tidal bars enables future studies on the sedimentary architecture of geologically complex tidal deposits and enables studying effects of man-induced perturbations such as dredging and dumping on bar and channel patterns and habitats.

  18. Effects of sea water environment on glass fiber reinforced plastic materials used for marine civil engineering constructions

    International Nuclear Information System (INIS)

    Garcia-Espinel, J.D.; Castro-Fresno, D.; Parbole Gayo, P.; Ballester-Muñoz, F.

    2015-01-01

    Highlights: • Seawater environment over composite material that are suitable for civil applications. • Seawater intake is linked to tensile and flexural strength degradation in GFC. • Fatigue performance of glass composites is similar in seawater environment than in air. - Abstract: Glass fiber composites (GFRP) are common in civil engineering projects, but not in marine structures. One reason is that seawater effects degrade GFRP composites mechanical properties and interlaminar shear strength (ILSS). Here, influence of seawater environment is studied to determine the best composite materials for marine civil engineer applications, studying the influence of several factors in their mechanical properties. This is to determine safety factors to use in the design of structural calculations for marine applications. Glass/epoxy composites are the safest materials to use in marine civil structures as mechanical properties degradation becomes stabilized after moisture saturation level. UV and water cyclic analysis must be done to determine affection to transversal strength. Only vinylester GFRP has problems with biodegradation. GFRP fatigue performance is not influenced by seawater environment

  19. Corrosion on reinforced concrete structures. An application for the intermediate level radioactive waste container

    International Nuclear Information System (INIS)

    Arva, Alejandro; Alvarez, Marta G.; Duffo, Gustavo S.

    2003-01-01

    The behavior of steel reinforcement bars (rebars) for a high performance reinforced concrete made of sulfate resistant portland cement was evaluated from the rebars corrosion point of view. The results from the present work will be used to evaluate the materials properties to be used in the construction of the intermediate level radioactive waste disposal containers. The study is carried out evaluating the incidence of chloride and sulfate ions, as well as, concrete carbonation in the rebar corrosion process. The electrochemical parameters that characterize the corrosion process (corrosion potential [E corr ], polarisation resistance [Rp] and concrete electrical resistivity [ρ]) were monitored on specially designed reinforced concrete specimens. The results up to date (about 1000 days of exposure) reveal that the concrete under study provides to the steel reinforcement bars of a passive state against corrosion under the test conditions. An increasing tendency as a function of time of ρ is observed that corroborates the continuous curing process of concrete. The chloride and carbonation diffusion coefficients were also determined, and their values are comparable with those of high quality concrete. (author)

  20. Earthquake Resilient Bridge Columns Utilizing Damage Resistant Hybrid Fiber Reinforced Concrete

    OpenAIRE

    Trono, William Dean

    2014-01-01

    Modern reinforced concrete bridges are designed to avoid collapse and to prevent loss of life during earthquakes. To meet these objectives, bridge columns are typically detailed to form ductile plastic hinges when large displacements occur. California seismic design criteria acknowledges that damage such as concrete cover spalling and reinforcing bar yielding may occur in columns during a design-level earthquake. The seismic resilience of bridge columns can be improved through the use of a da...

  1. Compressive damage mechanism of GFRP composites under off-axis loading: Experimental and numerical investigations

    DEFF Research Database (Denmark)

    Zhou, H.W.; Li, H.Y.; Gui, L.L.

    2013-01-01

    the angle between the fiber direction and the loading vector goes from 0° to 45° (by 2.3–2.6 times), and then slightly increases (when the angle approaches 80–90°). At the low angles between the fiber and the loading vector, fiber buckling and kinking are the main mechanisms of fiber failure....... With increasing the angle between the fiber and applied loading, failure of glass fibers is mainly controlled by shear cracking. For the computational analysis of the damage mechanisms, 3D multifiber unit cell models of GFRP composites and X-FEM approach to the fracture modeling were used. The computational...

  2. Analysis for Behavior of Reinforcement Lap Splices in Deep Beams

    Directory of Open Access Journals (Sweden)

    Ammar Yaser Ali

    2018-03-01

    Full Text Available The present study includes an experimental and theoretical investigation of reinforced concrete deep beams containing tensile reinforcement lap splices at constant moment zone under static load. The study included two stages: in the first one, an experimental work included testing of eight simply supported RC deep beams having a total length (L = 2000 mm, overall depth (h= 600 mm and width (b = 150 mm. The tested specimens were divided into three groups to study the effect of main variables: lap length, location of splice, internal confinement (stirrups and external confinement (strengthening by CFRP laminates. The experimental results showed that the use of CFRP as external strengthening in deep beam with lap spliced gives best behavior such as increase in stiffness, decrease in deflection, delaying the cracks appearance and reducing the crack width. The reduction in deflection about (14-21 % than the unstrengthened beam and about (5-14 % than the beam with continuous bars near ultimate load. Also, it was observed that the beams with unstrengthened tensile reinforcement lap splices had three types of cracks: flexural, flexural-shear and splitting cracks while the beams with strengthened tensile reinforcement lap splices or continuous bars don’t observe splitting cracks. In the second stage, a numerical analysis of three dimensional finite element analysis was utilized to explore the behavior of the RC deep beams with tensile reinforcement lap splices, in addition to parametric study of many variables. The comparison between the experimental and theoretical results showed reasonable agreement. The average difference of the deflection at service load was less than 5%.

  3. Structural Effects of Reinforced Concrete Beam Due to Corrosion

    Science.gov (United States)

    Noh, Hamidun Mohd; Idris, Nur'ain; Noor, Nurazuwa Md; Sarpin, Norliana; Zainal, Rozlin; Kasim, Narimah

    2018-03-01

    Corrosion of steel in reinforced concrete is one of the main issues among construction stakeholders. The main consequences of steel corrosion include loss of cross section of steel area, generation of expansive pressure which caused cracking of concrete, spalling and delaminating of the concrete cover. Thus, it reduces the bond strength between the steel reinforcing bar and concrete, and deteriorating the strength of the structure. The objective of this study is to investigate the structural effects of corrosion damage on the performance of reinforced concrete beam. A series of corroded reinforced concrete beam with a corrosion rate of 0%, 20% and 40% of rebar corrosion is used in parametric study to assess the influence of different level of corrosion rate to the structural performance. As a result, the used of interface element in the finite element modelling predicted the worst case of corrosion analysis since cracks is induced and generate at this surface. On the other hand, a positive linear relationship was sketched between the increase of expansive pressure and the corrosion rate. Meanwhile, the gradient of the graph is decreased with the increase of steel bar diameter. Furthermore, the analysis shows that there is a significant effect on the load bearing capacity of the structure where the higher corrosion rate generates a higher stress concentration at the mid span of the beam. This study could predict the residual strength of reinforced concrete beam under the corrosion using the finite element analysis. The experimental validation is needed on the next stage to investigate the quantitative relation between the corrosion rate and its influence on the mechanical properties.

  4. Deformation analysis of polymers composites: rheological model involving time-based fractional derivative

    DEFF Research Database (Denmark)

    Zhou, H. W.; Yi, H. Y.; Mishnaevsky, Leon

    2017-01-01

    A modeling approach to time-dependent property of Glass Fiber Reinforced Polymers (GFRP) composites is of special interest for quantitative description of long-term behavior. An electronic creep machine is employed to investigate the time-dependent deformation of four specimens of dog-bond-shaped......A modeling approach to time-dependent property of Glass Fiber Reinforced Polymers (GFRP) composites is of special interest for quantitative description of long-term behavior. An electronic creep machine is employed to investigate the time-dependent deformation of four specimens of dog......-bond-shaped GFRP composites at various stress level. A negative exponent function based on structural changes is introduced to describe the damage evolution of material properties in the process of creep test. Accordingly, a new creep constitutive equation, referred to fractional derivative Maxwell model...... by the fractional derivative Maxwell model proposed in the paper are in a good agreement with the experimental data. It is shown that the new creep constitutive model proposed in the paper needs few parameters to represent various time-dependent behaviors....

  5. A Comparison of Bond Performance of Concrete Reinforced with ...

    African Journals Online (AJOL)

    The transfer of stress from a deformed bar to the concrete is achieved by mechanical locking of the steel into the surrounding concrete. This interfacial bond strength between steel and the surrounding concrete is an important factor influencing the strength and durability of reinforced concrete structure. This paper presents ...

  6. Variability of chemical analysis of reinforcing bar produced in Saudi Arabia

    Science.gov (United States)

    Salman, A.; Djavanroodi, F.

    2018-04-01

    In view of the importance and demanding roles of steel rebar’s in the reinforced concrete structures, accurate information on the properties of the steels is important at the design stage. In the steelmaking process, production variations in chemical composition are unavoidable. The aim of this work is to study the variability of the chemical composition of reinforcing steel produced throughout the Saudi Arabia and asses the quality of steel rebar’s acoording to ASTM A615. 68 samples of ASTM A615 Grade 60 from different manufacturers were collected and tested using the Spectrometer test to obtain Chemical Compositions. EasyFit (5.6) software is utilized to conducted statistical analysis. Chemical compositions distributions and, control charts are generated for the compositions. Results showed that some compositions are above the upper line of the control chart. Finally, the analyses show that less than 3% of the steel failed to meet minimum ASTM standards for chemical composition.

  7. Stochastic Analysis of the Multi-dimensional Effect of Chloride Ingress into Reinforced Concrete

    DEFF Research Database (Denmark)

    Frier, Christian; Sørensen, John Dalsgaard

    2007-01-01

    For many reinforced concrete structures corrosion of the reinforcement is an important problem since it can result in expensive maintenance and repair actions. One mode of corrosion initiation occurs when the chloride content around the reinforcement bars exceeds a critical threshold value, which......, the assumption seems to be inaccurate. In this study, comparisons are made between analytical models based on infinite domains and series expansion solutions as well as numerical models based on FEM (Finite Element Method). As the parameters governing the problem are random in nature, MCS (Monte Carlo Simulation...

  8. Reinforced concrete wall under hydrogen detonation

    International Nuclear Information System (INIS)

    Saarenheimo, A.

    2000-11-01

    The structural integrity of a reinforced concrete wall in the BWR reactor building under hydrogen detonation conditions has been analysed. Of particular interest is whether the containment integrity can be jeopardised by an external hydrogen detonation. The load carrying capacity of a reinforced concrete wall was studied. The detonation pressure loads were estimated with computerised hand calculations assuming a direct initiation of detonation and applying the strong explosion theory. The results can be considered as rough and conservative estimates for the first shock pressure impact induced by a reflecting detonation wave. Structural integrity may be endangered due to slow pressurisation or dynamic impulse loads associated with local detonations. The static pressure following the passage of a shock front may be relatively high, thus this static or slowly decreasing pressure after a detonation may damage the structure severely. The mitigating effects of the opening of a door on pressure history and structural response were also studied. The non-linear behaviour of the wall was studied under detonations corresponding a detonable hydrogen mass of 0.5 kg and 1.428 kg. Non-linear finite element analyses of the reinforced concrete structure were carried out by the ABAQUS/Explicit program. The reinforcement and its non-linear material behaviour and the tensile cracking of concrete were modelled. Reinforcement was defined as layers of uniformly spaced reinforcing bars in shell elements. In these studies the surrounding structures of the non-linearly modelled reinforced concrete wall were modelled using idealised boundary conditions. Especially concrete cracking and yielding of the reinforcement was monitored during the numerical simulation. (au)

  9. Behaviour of concrete beams reinforced withFRP prestressed concrete prisms

    Science.gov (United States)

    Svecova, Dagmar

    The use of fibre reinforced plastics (FRP) to reinforce concrete is gaining acceptance. However, due to the relatively low modulus of FRP, in comparison to steel, such structures may, if sufficient amount of reinforcement is not used, suffer from large deformations and wide cracks. FRP is generally more suited for prestressing. Since it is not feasible to prestress all concrete structures to eliminate the large deflections of FRP reinforced concrete flexural members, researchers are focusing on other strategies. A simple method for avoiding excessive deflections is to provide sufficiently high amount of FRP reinforcement to limit its stress (strain) to acceptable levels under service loads. This approach will not be able to take advantage of the high strength of FRP and will be generally uneconomical. The current investigation focuses on the feasibility of an alternative strategy. This thesis deals with the flexural and shear behaviour of concrete beams reinforced with FRP prestressed concrete prisms. FRP prestressed concrete prisms (PCP) are new reinforcing bars, made by pretensioning FRP and embedding it in high strength grout/concrete. The purpose of the research is to investigate the feasibility of using such pretensioned rebars, and their effect on the flexural and shear behaviour of reinforced concrete beams over the entire loading range. Due to the prestress in the prisms, deflection of concrete beams reinforced with this product is substantially reduced, and is comparable to similarly steel reinforced beams. The thesis comprises both theoretical and experimental investigations. In the experimental part, nine beams reinforced with FRP prestressed concrete prisms, and two companion beams, one steel and one FRP reinforced were tested. All the beams were designed to carry the same ultimate moment. Excellent flexural and shear behaviour of beams reinforced with higher prestressed prisms is reported. When comparing deflections of three beams designed to have the

  10. Effects of the zinc and zinc-nickel alloys electroplating on the corrodibility of reinforced concrete rebars

    Directory of Open Access Journals (Sweden)

    F. A. CEDRIM

    Full Text Available Abstract This paper shows the analysis performed on the corrosion parameters of three groups of reinforcing steel bars, two of these coated by electroplating process with Zinc (Zn and Zinc-Nickel (Zn-Ni, and the other without any coating. It was used reinforced concrete specimens, which ones were grouped and then subjected to two different corrosion accelerating methods: aging wetting/drying cycles and salt spray exposure. Corrosion potential was measured to qualitative monitoring of the process and, after the end of the tests, corrosion rate was estimated by measuring the mass loss, to quantitative analyses. As it was expected, coated bars presented a better performance than the average bars regarding the corrosion resistance in chloride ions containing environments. It was also observed that the drying/ NaCl solution wetting cycles seems to be more severe than salt spray fog apparatus with respect to the acceleration of corrosion process.

  11. Quantitative analysis of the microstructure of interfaces in steel reinforced concrete

    International Nuclear Information System (INIS)

    Horne, A.T.; Richardson, I.G.; Brydson, R.M.D.

    2007-01-01

    This article reports the results of a backscattered electron imaging study of the microstructure of the steel- and aggregate-cement paste interfaces in concrete containing 9 mm ribbed reinforcing bars. The water to cement (w/c) ratio, hydration age, steel orientation, and surface finish were varied. For vertically cast bars, there was more calcium hydroxide (CH) and porosity and less unreacted cement at both the steel- and aggregate-cement paste interfaces when compared to the bulk cement paste. As the hydration age increased, the porosity near the interfaces decreased, and the CH increased with more CH close to the steel than to the aggregate. Horizontal bars had more porosity and less CH under them than above. An increase in the w/c ratio produced interfaces of higher porosity and lower levels of CH. Wire-brush cleaned bars had higher levels of CH at the steel-cement paste interface at 365 days when compared to uncleaned bars

  12. Characterization of Fibre-Direction Dependent Damping of Glass-Fibre Composites at Low Temperatures and Low Frequencies

    DEFF Research Database (Denmark)

    Kliem, Mathias; Høgsberg, Jan Becker; Dannemann, Martin

    2016-01-01

    This paper deals with the characterization of the fibre-direction dependent damping capability of glass fibre reinforced plastics (GFRP) to be used in electrical power transmission pylons. A fibre-direction dependent damping analysis of unidirectional (UD) GFRP samples was carried out using...... a Dynamic Mechanical Analysis (DMA) for five different fibre orientations (0˚ | 30˚ | 45˚ | 60˚ and 90˚) and two different matrix systems (epoxy and a vinyl ester resin). Based on the dynamic characteristics the damping performance of the various composite materials was studied at three temperatures (-10˚C......, 0˚C and 10˚C) and three vibration frequencies (1 Hz, 10 Hz and 30 Hz). It was observed that the loss factor of Glass Fibre Reinforced Vinyl-Ester (GF-VE) was in general slightly higher compared to the Glass Fibre Reinforced Epoxy (GF-EP). The loss factor increased slightly with temperature, while...

  13. The Potential of Sumatran Pine Rosin for Reinforcement-Steel Coating in Wet Environment

    Directory of Open Access Journals (Sweden)

    Rudi Hartono

    2018-01-01

    Full Text Available The corrosion of reinforcement-steel is commonly prevented by applying hydrophobic coating. In this work, the potential of residual product from Sumatran Pine sap distillation, known as Sumatran pine rosin or gondorukem, as a natural and environmentally-friendy resource to coat reinforcement-steel, and an initial assessment on its capability to prevent the corrosion in wet environment were investigated. The experiments were performed using two types of commercially available gondorukem, namely type T and U. The coated reinforcement-steel samples were immersed in collected rainwater and their physical changes were observed periodically for 60 days. The results showed that gondorukem improve the durability of the reinforcement-steel from corrosion in a severe rainwater contact. Keywords:  corrosion, coating, gondorukem, hydrophobic, pine rosin, reinforcement bar

  14. A numerical model for self-compacting concrete flow through reinforced sections. A porous medium analogy

    International Nuclear Information System (INIS)

    Vasilic, Ksenija

    2016-01-01

    This thesis addresses numerical simulations of self-compacting concrete (SCC) castings and suggests a novel modelling approach that treats reinforcement zones in a formwork as porous media. As a relatively new field in concrete technology, numerical simulations of fresh concrete flow can be a promising aid to optimise casting processes and to avoid on-site casting incidents by predicting the flow behaviour of concrete during the casting process. The simulations of fresh concrete flow generally involve complex mathematical modelling and time-consuming computations. In case of a casting prediction, the simulation time is additionally significantly increased because each reinforcement bar occurring in succession has to be considered one by one. This is particularly problematic when simulating SCC casting, since this type of concrete is typically used for heavily reinforced structural members. However, the wide use of numerical tools for casting prediction in practice is possible only if the tools are user-friendly and simulations are time-saving. In order to shorten simulation time and to come closer to a practical tool for casting prediction, instead to model steel bars one by one, this thesis suggests to model zones with arrays of steel bars as porous media. Consequently, one models the flow of SCC through a reinforcement zone as a free-surface flow of a non-Newtonian fluid, propagating through the medium. By defining characteristic parameters of the porous medium, the influence on the flow and the changed (apparent) behaviour of concrete in the porous matrix can be predicted. This enables modelling of any reinforcement network as a porous zone and thus significantly simplifies and fastens simulations of reinforced components' castings. Within the thesis, a computational model for SCC flow through reinforced sections was developed. This model couples a fluid dynamics model for fresh concrete and the macroscopic approach for the influence of the porous medium

  15. A numerical model for self-compacting concrete flow through reinforced sections. A porous medium analogy

    Energy Technology Data Exchange (ETDEWEB)

    Vasilic, Ksenija

    2016-05-01

    This thesis addresses numerical simulations of self-compacting concrete (SCC) castings and suggests a novel modelling approach that treats reinforcement zones in a formwork as porous media. As a relatively new field in concrete technology, numerical simulations of fresh concrete flow can be a promising aid to optimise casting processes and to avoid on-site casting incidents by predicting the flow behaviour of concrete during the casting process. The simulations of fresh concrete flow generally involve complex mathematical modelling and time-consuming computations. In case of a casting prediction, the simulation time is additionally significantly increased because each reinforcement bar occurring in succession has to be considered one by one. This is particularly problematic when simulating SCC casting, since this type of concrete is typically used for heavily reinforced structural members. However, the wide use of numerical tools for casting prediction in practice is possible only if the tools are user-friendly and simulations are time-saving. In order to shorten simulation time and to come closer to a practical tool for casting prediction, instead to model steel bars one by one, this thesis suggests to model zones with arrays of steel bars as porous media. Consequently, one models the flow of SCC through a reinforcement zone as a free-surface flow of a non-Newtonian fluid, propagating through the medium. By defining characteristic parameters of the porous medium, the influence on the flow and the changed (apparent) behaviour of concrete in the porous matrix can be predicted. This enables modelling of any reinforcement network as a porous zone and thus significantly simplifies and fastens simulations of reinforced components' castings. Within the thesis, a computational model for SCC flow through reinforced sections was developed. This model couples a fluid dynamics model for fresh concrete and the macroscopic approach for the influence of the porous medium

  16. CP asymmetries in B-bar → K-bar *( → K-bar π) l-bar l and untagged B-bar s, Bs → φ( → K+K-) l-bar l decays at NLO

    International Nuclear Information System (INIS)

    Bobeth, Christoph; Hiller, Gudrun; Piranishvili, Giorgi

    2008-01-01

    The decay B-bar → K-bar *( → K-bar π) l-bar l offers great opportunities to explore the physics at and above the electroweak scale by means of an angular analysis. We investigate the physics potential of the seven CP asymmetries plus the asymmetry in the rate, working at low dilepton mass using QCD factorization at next-to leading order (NLO). The b → s CP asymmetries are doubly Cabibbo-suppressed ∼ d , B d → K*( → K 0 π 0 ) l-bar l and B-bar s , B s → φ( → K + K - ) l-bar l decays. Analyses of these CP asymmetries can rule out, or further support the minimal description of CP violation through the CKM mechanism. Experimental studies are promising for (super) flavor factories and at hadron colliders.

  17. Study of the reactions $\\bar{p}p \\rightarrow \\bar{\\Lambda} \\Lambda , \\bar{\\Lambda} \\Sigma^{0}$ or $\\bar{\\Sigma^{0}} \\Lambda , \\bar{\\Sigma^{+}} \\Sigma^{+}$ at 3.6 GeV/c

    CERN Document Server

    Atherton, Henry W; Moebes, J P; Quercigh, Emanuele

    1974-01-01

    The reactions $\\bar{p}p \\rightarrow \\bar{\\Lambda} \\Lambda , \\bar{\\Lambda} \\Sigma^{0}$ or $\\bar{\\Sigma^{0}} \\Lambda , \\bar{\\Sigma^{+}} \\Sigma^{+}$ are studied at an incident momentum of 3.6 GeV/c in a 35.4 event/$\\mu$ b experiment performed in the CERN 2m HBC. Total and differential cross sections are presented. The polarization of the hyperons is measured as a function of $t$ and for the reaction $\\bar{p}p \\rightarrow \\bar{\\Lambda} \\Lambda$ the complete spin correlation matrix is given. (23 refs).

  18. The Possible Heavy Tetraquarks $qQ\\bar q \\bar Q$, $qq\\bar Q \\bar Q$ and $qQ\\bar Q \\bar Q$

    OpenAIRE

    Cui, Ying; Chen, Xiao-Lin; Deng, Wei-Zhen; Zhu, Shi-Lin

    2006-01-01

    Assuming X(3872) is a $qc \\bar q \\bar c$ tetraquark and using its mass as input, we perform a schematic study of the masses of possible heavy tetraquarks using the color-magnetic interaction with the flavor symmetry breaking corrections.

  19. Flow modelling of steel fibre reinforced self-compacting concrete

    DEFF Research Database (Denmark)

    Svec, Oldrich

    was done by means of the Immersed boundary method with direct forcing. Evolution of the immersed particles was described by Newton's differential equations of motion. The Newton's equations were solved by means of Runge-Kutta-Fehlberg iterative scheme. Several challenges had to be overcome during...... in concrete can efficiently substitute or supplement conventional steel reinforcement, such as reinforcement bars. Ordinary concrete composition further makes the material stiff and non-flowable. Self-compacting concrete is an alternative material of low yield stress and plastic viscosity that does flow...... of the fluid near formwork surface. A method to incorporate the apparent slip into the Lattice Boltzmann fluid dynamics solver was suggested. The proposed numerical framework was observed to correctly predict flow of fibre reinforced self-compacting concrete. The proposed numerical framework can therefore...

  20. Study on reinforced concrete high-rise building using prefabricated beam-column joints. Part 3. ; Basic anchorage behaviors of longitudinal bars of beams. Hahsirater dot hari setsugobu PC ka koho (PG connection koho) wo mochiita RC koso tatemono no kaihatsu. 3. ; Hari shukin no kisoteki teichaku seijo

    Energy Technology Data Exchange (ETDEWEB)

    SEkine, M.; Yoshioka, K.; Eto, H. (Obayashi Corp., Tokyo (Japan))

    1991-08-10

    Pull-out tests were carried out to examine basic anchorage behaviors of through holes for beam re-bars by using a PG connection method, in which columns and beam-column joints with through holes for beam re-bars in the reinforced concrete framed construction are precast simultaneously. Specimens made by the PG connection method showed better anchorage behaviors than specimens made by the conventional anchorage method. In case of anchorage width of 80cm and concrete strength of about 350kgf/cm{sup 2}, it was recognized that large slipping of re-bars did not occur under allowable bond stress when the interval between re-bars was not less than 15cm and covering depth to the core of re-bars was not less than 8cm. Concerning a specimen which did not show splitting bond failure because of lateral compressive stress, bond stress of re-bars when large slipping occurred was 1.5 times or more in comparison with the allowable bond stress. Since this specimen held high slipping rigidity even after increase of slipping, its anchoring stress increased by 32-57% compared with a specimen without lateral compressive stress. 4 refs., 7 figs., 3 tabs.

  1. TECHNOLOGY FOR INSTALLATION OF REINFORCED CONCRETE FLOOR SLABS LIGHTENED BY CORE DRIVERS WITH PRELIMINARY REINFORCEMENT STRESS

    Directory of Open Access Journals (Sweden)

    S. N. Leonovich

    2015-01-01

    Full Text Available The paper presents technology for installation of floor slabs lightened by plastic core drivers which are preliminary stressed under construction conditions.  Efficiency of such constructive solution is justified by the action of preliminary concrete compression in the tensile zone while reducing structure dead weight due to void arrangement.  The paper provides classification of systems for preliminary stress and contains recommendations on selection of the system depending on peculiariar features of the designed construction.  Main products and materials required for execution of works , requirements to stressed wire rope reinforcement, its main characteristics have been considered in the paper.Principal diagram of the lightened preliminary stressed slab stipulates arrangement of so called  dummy caisson. Strands of reinforcement ropes are located within the framework of bars passing over supporting structures (over vertical bearing structures of  the framework and voids are formed in the cells between bars by laying hollow plastic items joined together by a cage. The paper presents technological sequence of operations required for arrangement of the lightened preliminary stressed slab, schemes for equipment arrangement and characteristics of the applied devices and units (pushing device for reinforcement ropes, hydraulic jack with delivery hydraulic pump, mixing station, injection pump and others.  Recommendations have been given for execution of works in cold weather. The paper considers problems pertaining to control quality of the materials and items which are supplied to a construction site and directly execution of works on preliminary stress of a cellular slab.The executed analysis of technology permits to conclude that it is characterized by high level of applicability for import substitution. It is necessary to consider the possibility to apply the technology at objects of various application while comparing it with other

  2. Energy absorption at high strain rate of glass fiber reinforced mortars

    Directory of Open Access Journals (Sweden)

    Fenu Luigi

    2015-01-01

    Full Text Available In this paper, the dynamic behaviour of cement mortars reinforced with glass fibers was studied. The influence of the addition of glass fibers on energy absorption and tensile strength at high strain-rate was investigated. Static tests in compression, in tension and in bending were first performed. Dynamic tests by means of a Modified Hopkinson Bar were then carried out in order to investigate how glass fibers affected energy absorption and tensile strength at high strain-rate of the fiber reinforced mortar. The Dynamic Increase Factor (DIF was finally evaluated.

  3. A multimodal data-set of a unidirectional glass fibre reinforced polymer composite

    Directory of Open Access Journals (Sweden)

    Monica J. Emerson

    2018-06-01

    Full Text Available A unidirectional (UD glass fibre reinforced polymer (GFRP composite was scanned at varying resolutions in the micro-scale with several imaging modalities. All six scans capture the same region of the sample, containing well-aligned fibres inside a UD load-carrying bundle. Two scans of the cross-sectional surface of the bundle were acquired at a high resolution, by means of scanning electron microscopy (SEM and optical microscopy (OM, and four volumetric scans were acquired through X-ray computed tomography (CT at different resolutions. Individual fibres can be resolved from these scans to investigate the micro-structure of the UD bundle. The data is hosted at https://doi.org/10.5281/zenodo.1195879 and it was used in Emerson et al. (2018 [1] to demonstrate that precise and representative characterisations of fibre geometry are possible with relatively low X-ray CT resolutions if the analysis method is robust to image quality. Keywords: Geometrical characterisation, Polymer-matrix composites (PMCs, Volumetric fibre segmentation, Automated fibre tracking, X-ray imaging, Microscopy, Non-destructive testing

  4. [Interneuronal relationships in the basolateral amygdala of cats trained for choice in the quality of food reinforcement].

    Science.gov (United States)

    Merzhanova, G Kh; Dolbakian, E E; Partev, A Z

    1997-01-01

    The alimentary instrumental conditioned bar-pressing reflex was elaborated in cats by the method of "active choice" of either short-delayed reinforcement with bread-meat mixture of delayed more valuable reinforcement with meat. The animals differed in behavior strategy: some animals preferred bar-pressing with the long delay (the so-called "self-control" group), other animals pressed the bar with short delay (the so-called "impulsive" group). The multiunit activity in the basolateral amygdala was recorded with chronically implanted nichrome microelectrodes. The interactions between the spike trains of the neighbouring neurons selected from the multiunit activity were evaluated by means of statistical crosscorrelation analysis. It was shown that the number of correlations between the discharges of neurons was significantly higher in the "impulsive" cats. In both groups the number of cross-correlations was maximal in cases of a difficult choice, i.e., during the omission of the conditioned bar-pressing response. In "impulsive" cats the number of interneuronal correlations was highest with the latencies in the range of 0-30 msec. We suggest that the basolateral amygdala is involved in the system of structures which determine the individual-typological characteristics of animals.

  5. Triply heavy tetraquark states with the $QQ\\bar{Q}\\bar{q}$ configuration

    OpenAIRE

    Chen, Kan; Liu, Xiang; Wu, Jing; Liu, Yan-Rui; Zhu, Shi-Lin

    2016-01-01

    In the framework of the color-magnetic interaction, we systematically investigate the mass splittings of the $QQ\\bar{Q}\\bar{q}$ tetraquark states and estimated their rough masses in this work. These systems include the explicitly exotic states $cc\\bar{b}\\bar{q}$ and $bb\\bar{c}\\bar{q}$ and the hidden exotic states $cc\\bar{c}\\bar{q}$, $cb\\bar{b}\\bar{q}$, $bc\\bar{c}\\bar{q}$, and $bb\\bar{b}\\bar{q}$. If a state around the estimated mass region could be observed, its nature as a genuine tetraquark ...

  6. Finite Element Model for Nonlinear Analysis of Reinforced Concrete Beams and Plane Frames

    Directory of Open Access Journals (Sweden)

    R.S.B. STRAMANDINOLI

    Full Text Available Abstract In this work, a two-dimensional finite element (FE model for physical and geometric nonlinear analysis of reinforced concrete beams and plane frames, developed by the authors, is presented. The FE model is based on the Euler-Bernoulli Beam Theory, in which shear deformations are neglected. The bar elements have three nodes with a total of seven degrees of freedom. Three Gauss-points are utilized for the element integration, with the element section discretized into layers at each Gauss point (Fiber Model. It is assumed that concrete and reinforcing bars are perfectly bonded, and each section layer is assumed to be under a uniaxial stress-state. Nonlinear constitutive laws are utilized for both concrete and reinforcing steel layers, and a refined tension-stiffening model, developed by the authors, is included. The Total Lagrangean Formulation is adopted for geometric nonlinear consideration and several methods can be utilized to achieve equilibrium convergence of the nonlinear equations. The developed model is implemented into a computer program named ANEST/CA, which is validated by comparison with some tests on RC beams and plane frames, showing an excellent correlation between numerical and experimental results.

  7. Reliability Analysis of Corroded Reinforced Concrete Beams Using Enhanced HL-RF Method

    Directory of Open Access Journals (Sweden)

    Arash Mohammadi Farsani

    2015-12-01

    Full Text Available Steel corrosion of bars in concrete structures is a complex process which leads to the reduction of the cross-section bars and decreasing the resistance of the concrete and steel materials. In this study, reliability analysis of a reinforced concrete beam with corrosion defects under the distributed load was investigated using the enhanced Hasofer-Lind and Rackwitz-Fiessler (EHL-RF method based on relaxed approach. Robustness of the EHL-RF algorithm was compared with the HL-RF using a complicated example. It was seen that the EHL-RF algorithm is more robust than the HL-RF method. Finally, the effects of corrosion time were investigated using the EHL-RF algorithm for a reinforced concrete beam based on flexural strength in the pitting and general corrosion. The model uncertainties were considered in the resistance and load terms of flexural strength limit state function. The results illustrated that increasing the corrosion time-period leads to increase in the failure probability of the corroded concrete beam.

  8. Development of connecting method for mechanically cut reinforced concrete blocks

    International Nuclear Information System (INIS)

    Nishiuchi, Tatsuo

    2005-01-01

    The purpose of the study is to develop a practical method of disposing and recycling in dismantled reinforced concrete structures. We have devised a new method in which mechanically cut reinforced concrete blocks are connected and they are reused as a structural beam. In this method, concrete blocks are connected with several steel bars and the connected surface is wrapped with a fiber sheet. We verified that the load capacity of renewal beams was considerably large as same as that of continuous structural beams on the basis of experimental as well as numerical analysis results. As far as construction cost of reinforced concrete walls are concerned, we demonstrated that the cost of this method is slightly lower than that of the plan to use new and recycle materials. (author)

  9. Numerical Simulation on the Dynamic Splitting Tensile Test of reinforced concrete

    Science.gov (United States)

    Zhao, Zhuan; Jia, Haokai; Jing, Lin

    2018-03-01

    The research for crack resistance was of RC was based on the split Hopkinson bar and numerical simulate software LS-DYNA3D. In the research, the difference of dynamic splitting failure modes between plane concrete and reinforced concrete were completed, and the change rule of tensile stress distribution with reinforcement ratio was studied; also the effect rule with the strain rate and the crack resistance was also discussed by the radial tensile stress time history curve of RC specimen under different loading speeds. The results shows that the reinforcement in the concrete can impede the crack extension, defer the failure time of concrete, increase the tension intensity of concrete; with strain rate of concrete increased, the crack resistance of RC increased.

  10. RELATING BOTTOM QUARK MASS IN DR-BAR AND MS-BAR REGULARIZATION SCHEMES

    International Nuclear Information System (INIS)

    2002-01-01

    The value of the bottom quark mass at Q = M Z in the (bar D)(bar R) scheme is an important input for the analysis of supersymmetric models with a large value of tan β. Conventionally, however, the running bottom quark mass extracted from experimental data is quoted in the (bar M)(bar S) scheme at the scale Q = m b . We describe a two loop procedure for the conversion of the bottom quark mass from (bar M)(bar S) to (bar D)(bar R) scheme. The Particle Data Group value m b # bar M# # bar S#(m b # bar M# # bar S#) = 4.2 ± 0.2 GeV corresponds to a range of 2.65-3.03 GeV for m b # bar D# # bar R#(M Z )

  11. Niobium Carbide-Reinforced Al Matrix Composites Produced by High-Energy Ball Milling

    Science.gov (United States)

    Travessa, Dilermando Nagle; Silva, Marina Judice; Cardoso, Kátia Regina

    2017-06-01

    Aluminum and its alloys are key materials for the transportation industry as they contribute to the development of lightweight structures. The dispersion of hard ceramic particles in the Al soft matrix can lead to a substantial strengthening effect, resulting in composite materials exhibiting interesting mechanical properties and inspiring their technological use in sectors like the automotive and aerospace industries. Powder metallurgy techniques are attractive to design metal matrix composites, achieving a homogeneous distribution of the reinforcement into the metal matrix. In this work, pure aluminum has been reinforced with particles of niobium carbide (NbC), an extremely hard and stable refractory ceramic. Its use as a reinforcing phase in metal matrix composites has not been deeply explored. Composite powders produced after different milling times, with 10 and 20 vol pct of NbC were produced by high-energy ball milling and characterized by scanning electron microscopy and by X-ray diffraction to establish a relationship between the milling time and size, morphology, and distribution of the particles in the composite powder. Subsequently, an Al/10 pct NbC composite powder was hot extruded into cylindrical bars. The strength of the obtained composite bars is comparable to the commercial high-strength, aeronautical-grade aluminum alloys.

  12. The use of a Phosphate-Based Migrating Corrosion Inhibitor to Repair Reinforced Concrete Elements Contaminated by Chlorides

    Science.gov (United States)

    Tittarelli, Francesca; Mobili, Alessandra; Bellezze, Tiziano

    2017-08-01

    The use of sodium monofluorophosphate (MFP) was experimented as migrator inhibiting treatment against corrosion of reinforced concrete elements induced by chlorides. The results show that sodium monofluorophosphate, applied by surface impregnation, is able to slow down reinforcement corrosion only for reinforcing steel bars with concrete cover not thicker than 1 cm. This limitation is most probably due to the difficulty, with the type of application adopted, in making MFP to reach concentrations high enough to inhibit the corrosive process at greater depths from the impregnation surface.

  13. Behavior of masonry strengthened infilled reinforced concrete frames under in-plane load

    Directory of Open Access Journals (Sweden)

    Lila M. Abdel-Hafez

    2015-08-01

    The ductility of infilled frame strengthened with ferrocement was the best of all strengthened frames, while strengthening with GFRP increases its ultimate load carrying capacity but reduces its ductility.

  14. Application of a Reinforced Self-Compacting Concrete Jacket in Damaged Reinforced Concrete Beams under Monotonic and Repeated Loading

    Directory of Open Access Journals (Sweden)

    Constantin E. Chalioris

    2013-01-01

    Full Text Available This paper presents the findings of an experimental study on the application of a reinforced self-compacting concrete jacketing technique in damaged reinforced concrete beams. Test results of 12 specimens subjected to monotonic loading up to failure or under repeated loading steps prior to total failure are included. First, 6 beams were designed to be shear dominated, constructed by commonly used concrete, were initially tested, damaged, and failed in a brittle manner. Afterwards, the shear-damaged beams were retrofitted using a self-compacting concrete U-formed jacket that consisted of small diameter steel bars and U-formed stirrups in order to increase their shear resistance and potentially to alter their initially observed shear response to a more ductile one. The jacketed beams were retested under the same loading. Test results indicated that the application of reinforced self-compacting concrete jacketing in damaged reinforced concrete beams is a promising rehabilitation technique. All the jacketed beams showed enhanced overall structural response and 35% to 50% increased load bearing capacities. The ultimate shear load of the jacketed beams varied from 39.7 to 42.0 kN, whereas the capacity of the original beams was approximately 30% lower. Further, all the retrofitted specimens exhibited typical flexural response with high values of deflection ductility.

  15. Development of a relationship between external measurements and reinforcement stress

    Science.gov (United States)

    Brault, Andre; Hoult, Neil A.; Lees, Janet M.

    2015-03-01

    As many countries around the world face an aging infrastructure crisis, there is an increasing need to develop more accurate monitoring and assessment techniques for reinforced concrete structures. One of the challenges associated with assessing existing infrastructure is correlating externally measured parameters such as crack widths and surface strains with reinforcement stresses as this is dependent on a number of variables. The current research investigates how the use of distributed fiber optic sensors to measure reinforcement strain can be correlated with digital image correlation measurements of crack widths to relate external crack width measurements to reinforcement stresses. An initial set of experiments was undertaken involving a series of small-scale beam specimens tested in three-point bending with variable reinforcement properties. Relationships between crack widths and internal reinforcement strains were observed including that both the diameter and number of bars affected the measured maximum strain and crack width. A model that uses measured crack width to estimate reinforcement strain was presented and compared to the experimental results. The model was found to provide accurate estimates of load carrying capacity for a given crack width, however, the model was potentially less accurate when crack widths were used to estimate the experimental reinforcement strains. The need for more experimental data to validate the conclusions of this research was also highlighted.

  16. Performance simulation of BaBar DIRC bar boxes in TORCH

    Science.gov (United States)

    Föhl, K.; Brook, N.; Castillo García, L.; Cussans, D.; Forty, R.; Frei, C.; Gao, R.; Gys, T.; Harnew, N.; Piedigrossi, D.; Rademacker, J.; Ros García, A.; van Dijk, M.

    2017-12-01

    TORCH is a large-area precision time-of-flight detector based on the DIRC principle. The DIRC bar boxes of the BaBar experiment at SLAC could possibly be reused to form a part of the TORCH detector time-of-flight wall area, proposed to provide positive particle identification of low momentum kaons in the LHCb experiment at CERN. For a potential integration of BaBar bar boxes into TORCH, new imaging readout optics are required. From the several designs of readout optics that have been considered, two are used in this paper to study the effect of BaBar bar optical imperfections on the detector reconstruction performance. The kaon-pion separation powers obtained from analysing simulated photon hit patterns show the performance reduction for a BaBar bar of non-square geometry compared to a perfectly rectangular cross section.

  17. Prediction of the comparative reinforcement values of running and drinking.

    Science.gov (United States)

    PREMACK, D

    1963-03-15

    The probability of free drinking and running in rats was controlled by sucrose concentration and force requirements on an activity wheel. Drinking and running were then made contingent on pressing a bar. Barpressing increased monotonically with the associated response probability, and equally for drinking and running. The results support the assumption that different responses of equal probability have equal reinforcement value.

  18. Structural behavior of lightweight bamboo reinforced concrete slab with EPS infill panel

    Science.gov (United States)

    Wibowo, Ari; Wijatmiko, Indradi; Nainggolan, Christin Remayanti

    2017-09-01

    Eco-friendly, green, and natural materials have become increasingly important issues in supporting sustainable development, for the substitution of nonrenewable materials such as steel. Bamboo has been considered in many studies to replace steel in reinforced concrete elements. Further investigation has been carried out to obtain lightweight and eco-friendly reinforced concrete slabs by using bamboo bars as reinforcement and recycled materials such as EPS (expanded polystyrene) as infill panel. The flexural loading test on full scale one-way slabs test has been conducted. The results showed that the flexural strength of specimens decreased marginally of about 6% but with the weight advantage of 27% less compared with those of steel rebar reinforced concrete slab with the same dimension. Two type shear-connectors comprising of concrete and bamboo studs were also investigated which showed that the bamboo stud provided better ductility compared to that of slab with concrete as shear connector. Overall, the reinforced concrete slab with bamboo reinforcement and EPS infill panel showed reasonably good performance compared to slabs with steel rebar.

  19. Development of aluminothermic welding technology for assembly of reinforcement blocks for nuclear power plants

    International Nuclear Information System (INIS)

    Janicko, S.

    1984-01-01

    The newly developed technology of aluminothermic welding of reinforcing bars is used for the construction of reinforcements, turbine foundations, platforms, bubbling depressurization towers, etc. The method makes possible a good welding of the ends of the reinforcement and reproducibility of welded joints properties without the influence of the human factor on quality. The chemical composition of the weld has a higher content of C and Si which is important with regard to strength. Tensile strength, hardness (ranging from 188 to 270 HV 300), notch toughness (11 to 113 J.cm -2 ) and integrity were assessed. The savings achieved by introduction of the new technology are 1.783 h/weld. (J.H.)

  20. Carbon fiber reinforced materials - glass fiber reinforced materials

    Energy Technology Data Exchange (ETDEWEB)

    Krautwald, R

    1980-10-01

    Wind power plants are promising alternative energy systems. The rotor blades are subject to high demands: Long life, light weight, and high stiffness. A GFRP/CFRP combination was chosen for a 316 kW plant, the composite construction is by far superior to the metal construction. Design, fabrication, and testing are described. The plant has a power of 316 kW for a wind velocity of 8.5 m/sec, a rotational speed of 37 min/sup -1/, a rotor diameter of 52 m with a blade length of 25.2 m and a blade mass of 1 t. An experimental component 10.2 m long was constructed and tested with satisfactory results.

  1. Degradation of basalt fibre and glass fibre/epoxy resin composites in seawater

    International Nuclear Information System (INIS)

    Wei Bin; Cao Hailin; Song Shenhua

    2011-01-01

    Research highlights: → BFRP degradation process in seawater environment was first investigated. → The mass gain change includes two effects: absorption and extraction. → The interfacial adhesion of BFRP is bigger than GFRP. → After treated, the bending strength of BFRP is lower than GFRP. → Reducing the Fe 2+ in the basalt fibre could lead to a higher stability of BFRP. - Abstract: Epoxy resins reinforced, respectively, by basalt fibres and glass fibres were treated with a seawater solution for different periods of time. Both the mass gain ratio and the strength maintenance ratio of the composites were examined after the treatment. The fracture surfaces were characterized using scanning electron microscopy. The tensile and bending strengths of the seawater treated samples showed a decreasing trend with treating time. In general, the anti-seawater corrosion property of the basalt fibre reinforced composites was almost the same as that of the glass fibre reinforced ones. Based on the experimental results, possible corrosion mechanisms were explored, indicating that an effective lowering of the Fe 2+ content in the basalt fibre could lead to a higher stability for the basalt fibre reinforced composites in a seawater environment.

  2. Mathematical modeling for corrosion environment estimation based on concrete resistivity measurement directly above reinforcement

    International Nuclear Information System (INIS)

    Lim, Young-Chul; Lee, Han-Seung; Noguchi, Takafumi

    2009-01-01

    This study aims to formulate a resistivity model whereby the concrete resistivity expressing the environment of steel reinforcement can be directly estimated and evaluated based on measurement immediately above reinforcement as a method of evaluating corrosion deterioration in reinforced concrete structures. It also aims to provide a theoretical ground for the feasibility of durability evaluation by electric non-destructive techniques with no need for chipping of cover concrete. This Resistivity Estimation Model (REM), which is a mathematical model using the mirror method, combines conventional four-electrode measurement of resistivity with geometric parameters including cover depth, bar diameter, and electrode intervals. This model was verified by estimation using this model at areas directly above reinforcement and resistivity measurement at areas unaffected by reinforcement in regard to the assessment of the concrete resistivity. Both results strongly correlated, proving the validity of this model. It is expected to be applicable to laboratory study and field diagnosis regarding reinforcement corrosion. (author)

  3. Reinforced concrete bridges: effects due to corrosion and concrete young modulus variation

    Directory of Open Access Journals (Sweden)

    P. T. C. Mendes

    Full Text Available Most of the Brazilian bridges of federal road network are made of reinforced concrete and are more than 30 years old, with little information about the mechanical properties of their constitutive materials. Along the service life of these bridges much modification occurred on vehicles load and geometry and in design standard. Many of them show signs of concrete and steel deterioration and their stability conditions are unknown. With the aim of contributing to the structural evaluation of reinforced concrete bridges it was decided to analyze the stresses in reinforced concrete bridge sections to verify the effects due to reinforcement corrosion and variation of the concrete Young modulus on the stress distribution regarding several load patterns and cracking effects in a representative bridge of the Brazilian road network with different longitudinal reinforcement taxes and two concrete Young modulus, Ec and 0.5Ec, and with different percentage of reinforcement corrosion. The analysis considered two finite element models: frame and shell elements as well as solid elements. The results indicate that these variation effects are more significant in reinforcement bars than in concrete.

  4. Enamel coated steel reinforcement for improved durability and life-cycle performance of concrete structures: microstructure, corrosion, and deterioration

    Science.gov (United States)

    Tang, Fujian

    This study is aimed (a) to statistically characterize the corrosion-induced deterioration process of reinforced concrete structures (concrete cracking, steel mass loss, and rebar-concrete bond degradation), and (b) to develop and apply three types of enamel-coated steel bars for improved corrosion resistance of the structures. Commercially available pure enamel, mixed enamel with 50% calcium silicate, and double enamel with an inner layer of pure enamel and an outer layer of mixed enamel were considered as various steel coatings. Electrochemical tests were respectively conducted on steel plates, smooth bars embedded in concrete, and deformed bars with/without concrete cover in 3.5 wt.% NaCl or saturated Ca(OH)2 solution. The effects of enamel microstructure, coating thickness variation, potential damage, mortar protection, and corrosion environment on corrosion resistance of the steel members were investigated. Extensive test results indicated that corrosion-induced concrete cracking can be divided into four stages that gradually become less correlated with corrosion process over time. The coefficient of variation of crack width increases with the increasing level of corrosion. Corrosion changed the cross section area instead of mechanical properties of steel bars. The bond-slip behavior between the corroded bars and concrete depends on the corrosion level and distribution of corrosion pits. Although it can improve the chemical bond with concrete and steel, the mixed enamel coating is the least corrosion resistant. The double enamel coating provides the most consistent corrosion performance and is thus recommended to coat reinforcing steel bars for concrete structures applied in corrosive environments. Corrosion pits in enamel-coated bars are limited around damage locations.

  5. Fiber reinforced concrete as a material for nuclear reactor containment buildings

    International Nuclear Information System (INIS)

    Mallikarjuna; Banthia, N.; Mindess, S.

    1991-01-01

    The fiber reinforced concrete as a constructional material for nuclear reactor containment buildings calls for an examination of its individual characteristics and potentialities due to its inherent superiority over normal plain and reinforced concrete. In the present investigation, first, to study the static behavior of straight, hooked-end and crimped fibers, recently developed nonlinear three-dimensional interface (contact) element has been used in conjunction with the eight nodded hexahedron and two nodded bar elements for concrete and steel fiber respectively. Then impact tests were carried out on fiber reinforced concrete beams with an instrumented drop weight impact machine. Two different concrete mixes were tested: normal strength and high strength concrete specimens. Fibers in the concrete mix found to significantly increase the ductility and the impact resistance of the composite. Deformed fibers increase peak pull-out load and pull-out distance, and perform better in the steel fiber reinforced concrete (SFRC) structures. (author)

  6. Corrosion of reinforcing bars embedded in alkali-activated slag concrete subjected to chloride attack

    Directory of Open Access Journals (Sweden)

    William Aperador Chaparro

    2012-02-01

    Full Text Available Steel bar embedded in an alkali-activated slag (AAS concrete was tested under complete immersion, in 3.5% NaCl solution by weight of the slag. Ordinary Portland cement (OPC was also tested for comparative purposes and exposed to the same solution. Monitoring of open-circuit potential, polarization resistance measurement and electrochemical impedance spectroscopy (EIS were used to evaluate the corrosion behavior of steel bar. The corrosion resistances of AAS and OPC concretes were performed at 0, 3, 6, 9 and 12 months. Electrochemical measurements shows that AAS concrete presents passive corrosion behavior the first 3 months, after this period of time, it presents corrosion resistance decreased due to the chlorides presence at the steel/AAS interface. For 0 months immersion (28 days of curing the AAS and OPC concretes presented a 10% of corrosion probability. After 3 months of immersion the tested AAS and OPC concretes showed similar behavior, the active potentials in the range from "0.2 to "0.6 V vs. Cu/CuSO4, indicate a 90% probability of corrosion.

  7. Qq(Q-bar)(q-bar)' states in chiral SU(3) quark model

    International Nuclear Information System (INIS)

    Zhang Haixia; Zhang Min; Zhang Zongye

    2007-01-01

    We study the masses of Qq(Q-bar)(q-bar)' states with J PC =0 ++ , 1 ++ , 1 +- and 2 ++ in the chiral SU(3) quark model, where Q is the heavy quark (c or b) and q(q') is the light quark (u,d or s). According to our numerical results, it is improbable to make the interpretation of [cn(c-bar)(n-bar)] 1 ++ and [cn(c-bar)(n-bar)] 2 ++ (n=u,d) states as X(3872) and Y(3940), respectively. However, it is interesting to find the tetraquarks in the bq(b-bar)(q-bar)' system. (authors)

  8. Improved Bond Equations for Fiber-Reinforced Polymer Bars in Concrete.

    Science.gov (United States)

    Pour, Sadaf Moallemi; Alam, M Shahria; Milani, Abbas S

    2016-08-30

    This paper explores a set of new equations to predict the bond strength between fiber reinforced polymer (FRP) rebar and concrete. The proposed equations are based on a comprehensive statistical analysis and existing experimental results in the literature. Namely, the most effective parameters on bond behavior of FRP concrete were first identified by applying a factorial analysis on a part of the available database. Then the database that contains 250 pullout tests were divided into four groups based on the concrete compressive strength and the rebar surface. Afterward, nonlinear regression analysis was performed for each study group in order to determine the bond equations. The results show that the proposed equations can predict bond strengths more accurately compared to the other previously reported models.

  9. EMBEDDED CAPACITOR SENSOR FOR MONITORING CORROSION OF REINFORCEMENT IN CONCRETE

    Directory of Open Access Journals (Sweden)

    SITI FATIMAH ABDUL RAHMAN

    2012-04-01

    Full Text Available Corrosion of reinforcement can affect durability and integrity of reinforced concrete structures. Repair cost for a badly corroded structure can be very costly and time consuming. In this paper, several capacitor sensors were developed to monitor corrosion potential of reinforcement in concrete. The impedance capacitive of sensors was tested in various acid and alkali solutions using Agilent 4284A Precision LCR meter. The other sensors were tied to reinforcements and embedded in concrete specimen contaminated with 5% chloride to measure corrosion potential. The specimens were exposed to the corrosion chamber and indoor environments. From the research, it was found that the sensor can measure the impedance capacitive at different frequencies in the aggressive solutions. Besides, it was observed that the patterns of corrosion potential shown by the embedded sensors were similar to the SRI sensor. The output values from embedded sensor are in a range of recommendation by the ASTM-C876. Eventually, the bars were found corroded from the broken specimens that confirmed the detection of corrosion activities as recorded by the sensors.

  10. submitter Performance simulation of BaBar DIRC bar boxes in TORCH

    CERN Document Server

    Föhl, K; Castillo García, L; Cussans, D; Forty, R; Frei, C; Gao, R; Gys, T; Harnew, N; Piedigrossi, D; Rademacker, J; Ros García, A; van Dijk, M

    2017-01-01

    TORCH is a large-area precision time-of-flight detector based on the DIRC principle. The DIRC bar boxes of the BaBar experiment at SLAC could possibly be reused to form a part of the TORCH detector time-of-flight wall area, proposed to provide positive particle identification of low momentum kaons in the LHCb experiment at CERN. For a potential integration of BaBar bar boxes into TORCH, new imaging readout optics are required. From the several designs of readout optics that have been considered, two are used in this paper to study the effect of BaBar bar optical imperfections on the detector reconstruction performance. The kaon-pion separation powers obtained from analysing simulated photon hit patterns show the performance reduction for a BaBar bar of non-square geometry compared to a perfectly rectangular cross section.

  11. Formation of q bar q resonances in the bar NN system

    International Nuclear Information System (INIS)

    Ivanov, N.Ya.

    1995-01-01

    The formation of q bar q resonances lying on the leading Regge trajectories in the bar NN system is studied in the quark-gluon string model. The model predicts strong suppression of the decays of q bar q states into bar NN pairs in relation to two-meson modes. The author's analysis shows that the contributions of the resonances f 4 (2050) (I G J PC = 0 + 4 ++ ), ρ 5 (2240) (I G J PC = 1 + 5 -- ), and f 6 (2510) (I G J PC = 0 + 6 ++ ) to the processes of two-meson bar NN annihilation (bar pp → ππ, bar KK, hor-ellipsis) are about 1% of the corresponding experimental integrated cross sections. 30 refs., 2 figs., 1 tab

  12. Production of n-bar's and Sigma-bar+-'s in e+e- annihilations

    International Nuclear Information System (INIS)

    Ferguson, T.; Buchanan, C.; Nodulman, L.; Poster, R.; Breidenbach, M.; Morehouse, C.C.; Vannucci, F.

    1979-01-01

    The production of antineutrons and charged Sigma-bar's in e + e - annihilations has been measured at √s +- production between 4 and 7 GeV is consistent with simple expectations for charmed-baryon production. A search for the decays Lambda-bar - /sub c/ → Sigma-bar +- π -+ π - and Sigma-baratsup asteriskat/sub c//Sigma-bar/sub c/ → Lambda-bar - /sub c/π +- yields no significant peaks. An upper limit, at the 90% confidence level, of sigmaatsub Lambda-baratc-italicB (Lambda-bar/sub c/ → Sigma-bar +- π -+ π - ) < 56 pb is set

  13. Anisotropic chemical etching of semipolar {101-bar 1-bar}/{101-bar +1} ZnO crystallographic planes: polarity versus dangling bonds

    International Nuclear Information System (INIS)

    Palacios-Lidon, E; Perez-GarcIa, B; Colchero, J; Vennegues, P; Zuniga-Perez, J; Munoz-Sanjose, V

    2009-01-01

    ZnO thin films grown by metal-organic vapor phase epitaxy along the nonpolar [112-bar] direction and exhibiting semipolar {101-bar 1-bar}/{101-bar +1} facets have been chemically etched with HCl. In order to get an insight into the influence of the ZnO wurtzite structure in the chemical reactivity of the material, Kelvin probe microscopy and convergent beam electron diffraction have been employed to unambiguously determine the absolute polarity of the facets, showing that {101-bar +1} facets are unstable upon etching in an HCl solution and transform into (000+1)/{101-bar 1-bar} planes. In contrast, {101-bar 1-bar} undergo homogeneous chemical etching perpendicular to the initial crystallographic plane. The observed etching behavior has been explained in terms of surface oxygen dangling bond density, suggesting that the macroscopic polarity plays a secondary role in the etching process.

  14. Full scale heavily reinforced concrete beam-column joints of NPP structures-quality assurance and construction in the laboratory

    International Nuclear Information System (INIS)

    Thandavamoorthy, T.S.; Vimalanandam, V.; Anandavalli, N.; Reddy, G.R.

    2003-01-01

    Under the current design philosophy, reactor structures are to be designed to withstand large inelastic deformation caused by strong and severe ground motion. The design of the main structural elements and their connections are to be such that they always fail in ductile mode. This will ensure large energy absorption capacity of the structures under seismic excitation and avoid sudden and brittle failure of the structure. Over the years, a number of experimental investigations have been carried out on RC beam- column joints to study their behaviour and strength. However, these studies mostly pertain to small scale joints of moment resisting frame of residential buildings and commercial complexes. Information on full scale joints existing in NPP structures are scanty. Therefore, experimental programme was planned in the laboratory to construct identical large sized joints with the same reinforcement percentage and detail as that of the existing joints in NPP structures built in 1960's. The cross-sectional dimensions of the beam and column of the joint were 610 mm x 915 mm. The beam was reinforced with 24 numbers of 36 mm bars. Column was reinforced with 4 numbers of 36 mm diameter bars and various other sizes. M25 grade concrete was used for casting of the specimen. The mix proportion was 1:1.657:2.63. The slump achieved was 75 mm to 100 mm. The health of the specimen was monitored by conducting ultrasonic testing with TICO instrument. The paper presents details of the size of the specimen and reinforcement, testing of steel bars for the evaluation of their mechanical properties, procedure of casting of specimen and its health monitoring. (author)

  15. Four bars inn; Four bars inn

    Energy Technology Data Exchange (ETDEWEB)

    Nishiumi, T. [National Defense Academy, Kanagawa (Japan)

    1999-05-15

    The name Four Bars Inn puns on four drinking bars and four bars on a musical score. It is a public house sited on the busy St. Mary Street, Cardiff, England. During my stay in that town, I often attended the regular jam session that opened at the bar at nine o`clock every Monday evening. A jam session is an event in which any amateur player, and a professional artist occasionally, is allowed to come on the stage freely and to play jazz, the participation fee as low as 300-yen. It is an occasion that provides a friendly meeting of man and woman, young and old, everyone carrying a pint of ale. Senior people happily talking to young ones aged like their grandchildren certainly presents a heart-warming scene, which we scarcely encounter in Japan. The affection that the British entertain toward their domestic furnishings relayed down through many a generation may lead to their respect for senior citizens. I heartily look forward detecting like scenes some day at drinking spots in Japan where the consumption-happy days are over. (NEDO)

  16. Field Testing of High Current Electrokinetic Nanoparticle Treatment for Corrosion Mitigation in Reinforced Concrete

    Science.gov (United States)

    Cardenas, Henry; Alexander, Joshua; Kupwade-Patil, Kunal; Calle, Luz marina

    2010-01-01

    Electrokinetic Nanoparticle (EN) treatment was used as a rapid repair measure to mitigate chloride induced corrosion of reinforced concrete in the field. EN treatment uses an electric field to transport positively charged nanoparticles to the reinforcement through the concrete capillary pores. Cylindrical reinforced concrete specimens were batched with 4.5 wt % salt content (based on cement mass). Three distinct electrokinetic treatments were conducted using high current density (up to 5 A/m2) to form a chloride penetration barrier that was established in 5 days, as opposed to the traditional 6-8 weeks, generally required for electrochemical chloride extraction (ECE). These treatments included basic EN treatment, EN with additional calcium treatment, and basic ECE treatment. Field exposures were conducted at the NASA Beachside Corrosion Test Site, Kennedy Space Center, Florida, USA. The specimens were subjected to sea water immersion at the test site as a posttreatment exposure. Following a 30-day post-treatment exposure period, the specimens were subjected to indirect tensile testing to evaluate treatment impact. The EN treated specimens exhibited 60% and 30% increases in tensile strength as compared to the untreated controls and ECE treated specimens respectively. The surfaces of the reinforcement bars of the control specimens were 67% covered by corrosion products. In contrast, the EN treated specimens exhibited corrosion coverage of only 4%. Scanning electron microscopy (SEM) revealed a dense concrete microstructure adjacent to the bars of the treated specimens as compared to the control and ECE specimens. Energy dispersive spectroscopic (EDS) analysis of the polished EN treated specimens showed a reduction in chloride content by a factor of 20 adjacent to the bars. This study demonstrated that EN treatment was successful in forming a chloride penetration barrier rapidly. This work also showed that the chloride barrier was effective when samples were exposed to

  17. Derivation of asymptotic Vertical BarΔIVertical Bar = 1/2 rule

    International Nuclear Information System (INIS)

    Terasaki, K.; Oneda, S.

    1982-01-01

    It is argued that the origin of the observed approximate Vertical BarΔIVertical Bar = 1/2 rule is the presence of an asymptotic Vertical BarΔIVertical Bar = 1/2 rule which exists among certain two-body hadronic weak matrix elements, involving especially the ground-state hadrons

  18. First Measurement of σ(gg → t$\\bar{t}$)/σ(p$\\bar{p}$ → t$\\bar{t}$)

    Energy Technology Data Exchange (ETDEWEB)

    Alamdari, Shabnaz Pashapour [Univ. of Toronto, ON (Canada)

    2008-01-01

    The work presented here is the first measurement of the fraction of top quark pair production through gluon-gluon fusion. We use an integrated luminosity of 0.96 ± 0.06 fb-1 of p{bar p} collisions at √s of 1.96 TeV collected by the CDF II detector. We select t$\\bar{t}$ candidates by identifying a high-pT lepton candidate, a large missing ET as evidence for a neutrino candidate and at least four high ET jets, one of which has to be identified as originating from a b quark. The challenge is to discriminate between the two production processes with the identical final state, gg → t$\\bar{t}$ and q$\\bar{p}$ → t$\\bar{t}$. We take advantage of the fact that compared to a quark, a gluon is more likely to radiate a low momentum gluon and therefore, one expects a larger number of charged particles with low pT in a process involving more gluons. Given the large uncertainties associated with the modeling of the low pT charged particle multiplicity, a data-driven technique was employed. Using calibration data samples, we show there exists a clear correlation between the observed average number of low pT charged particles and the average number of gluons involved in the production process predicted by Monte Carlo calculations. Given the correlation, one can identify low pT charged particle multiplicity distributions associated with specific average number of gluons. The W + 0 jet sample and dijets sample with leading jet ET in the range of 80-100 GeV are used to find no-gluon and gluon-rich low p{sub T} charged particle multiplicity distributions, respectively. Using these no-gluon and gluon-rich distributions in a likelihood fit, we find the fraction of gluon-rich events in t{bar t} candidates. This fraction has contributions from the signal and background events. Taking into account these contributions and the gg → t$\\bar{t}$ and q$\\bar{q}$ → t$\\bar

  19. The He+H-bar → Hep-bar +e+ rearrangement

    International Nuclear Information System (INIS)

    Todd, Allan C.; Armour, Edward A.G.

    2006-01-01

    In this paper, we present a summary of our work in progress on calculating cross sections for the He+H-bar ->Hep-bar +e + rearrangement process in HeH-bar scattering. This has involved a study of the system Hep-bar within the Born-Oppenheimer (BO) approximation using the Rayleigh-Ritz variational method. This work has been reported in [A.C. Todd, E.A.G. Armour, J. Phys. B 38 (2005) 3367] and is summarised here. Similar calculations are in progress for the He+H-bar entrance channel. We intend to use the entrance channel and rearrangement channel wave functions to obtain the cross sections for the rearrangement using the distorted wave Born approximation T-matrix method described elsewhere in these proceedings [E.A.G. Armour, S. Jonsell, Y. Liu, A.C. Todd, these Proceedings, doi:10.1016/j.nimb.2006.01.049

  20. Improving radiopharmaceutical supply chain safety by implementing bar code technology.

    Science.gov (United States)

    Matanza, David; Hallouard, François; Rioufol, Catherine; Fessi, Hatem; Fraysse, Marc

    2014-11-01

    The aim of this study was to describe and evaluate an approach for improving radiopharmaceutical supply chain safety by implementing bar code technology. We first evaluated the current situation of our radiopharmaceutical supply chain and, by means of the ALARM protocol, analysed two dispensing errors that occurred in our department. Thereafter, we implemented a bar code system to secure selected key stages of the radiopharmaceutical supply chain. Finally, we evaluated the cost of this implementation, from overtime, to overheads, to additional radiation exposure to workers. An analysis of the events that occurred revealed a lack of identification of prepared or dispensed drugs. Moreover, the evaluation of the current radiopharmaceutical supply chain showed that the dispensation and injection steps needed to be further secured. The bar code system was used to reinforce product identification at three selected key stages: at usable stock entry; at preparation-dispensation; and during administration, allowing to check conformity between the labelling of the delivered product (identity and activity) and the prescription. The extra time needed for all these steps had no impact on the number and successful conduct of examinations. The investment cost was reduced (2600 euros for new material and 30 euros a year for additional supplies) because of pre-existing computing equipment. With regard to the radiation exposure to workers there was an insignificant overexposure for hands with this new organization because of the labelling and scanning processes of radiolabelled preparation vials. Implementation of bar code technology is now an essential part of a global securing approach towards optimum patient management.

  1. Finite-Element Investigation of the Structural Behavior of Basalt Fiber Reinforced Polymer (BFRP- Reinforced Self-Compacting Concrete (SCC Decks Slabs in Thompson Bridge

    Directory of Open Access Journals (Sweden)

    Lingzhu Zhou

    2018-06-01

    Full Text Available The need for a sustainable development and improved whole life performance of concrete infrastructure has led to the requirement of more durable and sustainable concrete bridges alongside accurate predictive analysis tools. Using the combination of Self-Compacting Concrete (SCC with industrial by-products and fiber-reinforced polymer (FRP, reinforcement is anticipated to address the concerns of high carbon footprint and corrosion in traditional steel-reinforced concrete structures. This paper presents a numerical investigation of the structural behavior of basalt fiber-reinforced polymer (BFRP-reinforced SCC deck slabs in a real bridge, named Thompson Bridge, constructed in Northern Ireland, U.K. A non-linear finite element (FE model is proposed by using ABAQUS 6.10 in this study, which is aimed at extending the previous investigation of the field test in Thompson Bridge. The results of this field test were used to validate the accuracy of the proposed finite element model. The results showed good agreement between the test results and the numerical results; more importantly, the compressive membrane action (CMA inside the slabs could be well demonstrated by this FE model. Subsequently, a series of parametric studies was conducted to investigate the influence of different parameters on the structural performance of the deck slabs in Thompson Bridge. The results of the analyses are discussed, and conclusions on the behavior of the SCC deck slabs reinforced by BFRP bars are presented.

  2. Measurement of the asymmetry parameter for the decay $\\bar\\Lambda \\to \\bar p\\pi^+$

    OpenAIRE

    BES collaboration

    2009-01-01

    Based on a sample of $58\\times10^6J/\\psi$ decays collected with the BESII detector at the BEPC, the $\\bar\\Lambda$ decay parameter $\\alpha_{\\bar\\Lambda}$ for $\\bar\\Lambda\\to \\bar p \\pi^+$ is measured using about 9000 $J/\\psi\\to\\Lambda\\bar\\Lambda\\to p \\bar p \\pi^+\\pi^-$ decays. A fit to the joint angular distributions yields $\\alpha_{\\bar\\Lambda}(\\bar\\Lambda\\to \\bar p\\pi^+)=-0.755\\pm0.083\\pm0.063$, where the first error is statistical, and the second systematic.

  3. Performance evaluation of HSC beams with low flexural reinforcement

    Directory of Open Access Journals (Sweden)

    T.M. Elrakib

    2013-04-01

    Full Text Available The main objective of the current research is to establish experimental data for minimum flexural reinforcement, ρmin, of high strength concrete (HSC rectangular beams. Nine full-scale singly reinforced beams with flexural reinforcement ratios varying from 50% to 100% of the minimum limit specified by the ACI 363R-35were tested in flexure. Concrete compressive strengths of 52, 73 and 96.5 MPa were used. The test results including crack patterns, deflections and strains in the tensile flexural steel bars show that a 25% reduction of the ACI 363R-35 limit for the ρmin would result in a satisfactory flexural beam behavior with a reserve flexural parameter (Py,/Pcr ⩾ 1.29 and a displacement ductility index λΔ > 5 for all concrete grades which may lead to good savings in the amount of the flexural reinforcement. Also, it was noted that the displacement ductility index λΔ increased as the concrete compressive strength increased for the same ratio (ρ/ρmin up to 75 MPa and then decreases as fcu increases. For the same concrete compressive strength with low values of flexural reinforcement ratio, ρ, the displacement ductility index λΔ increased as ρ increased. The experimental results of this study were compared with the limits specified by available codes and researches.

  4. Prediction of the Service Life of a Reinforced Concrete Column under Chloride Environment

    Directory of Open Access Journals (Sweden)

    Mohammad K. Alkam

    2015-01-01

    Full Text Available In the present investigation, service life of a reinforced concrete column exposed to chloride environment has been predicted. This study has been based on numerical simulation of chloride ion diffusion in a concrete column during its anticipated life span. The simulation process has included the concrete cover replacement whenever chloride ion concentration has reached the critical threshold value at the reinforcement surface. Repair scheduling of the concrete column under consideration has been discussed. Effects of the concrete cover thickness and the water cement ratio on the service life of the concrete column at hand have been presented. A new approach for arranging locations of reinforcement steel bars has been introduced. This approach is intended to prolong the service life of the concrete column under consideration against chloride induced corrosion.

  5. A Study of (bar B)0 --> D(*)0 (bar K)(*)0 Decays

    International Nuclear Information System (INIS)

    Aubert, B.

    2004-01-01

    The authors presented evidence for the decay (bar B) 0 --> D* 0 (bar K) 0 as well as new measurements of the branching fractions for the decays (bar B) 0 --> D 0 (bar K) 0 and D 0 (bar K)* 0 . Their measurements are in agreement with the expectation derived from a cited reference and with previous measurements. They use the central value of their measurement for B((bar B) 0 --> (bar D) 0 K* 0 ) and obtain τ < 0.8 at the 90% C.L. from a central value of τ = 0.4 ± 0.2 (stat.) ± 0.2 (syst.). The main contribution to the systematic uncertainty is from the estimated peaking background since most systematic uncertainties on the branching fractions cancel in the ratio

  6. Crack identification for reinforced concrete using PZT based smart rebar active sensing diagnostic network

    Science.gov (United States)

    Song, N. N.; Wu, F.

    2016-04-01

    An active sensing diagnostic system using PZT based smart rebar for SHM of RC structure has been currently under investigation. Previous test results showed that the system could detect the de-bond of concrete from reinforcement, and the diagnostic signals were increased exponentially with the de-bonding size. Previous study also showed that the smart rebar could function well like regular reinforcement to undertake tension stresses. In this study, a smart rebar network has been used to detect the crack damage of concrete based on guided waves. Experimental test has been carried out for the study. In the test, concrete beams with 2 reinforcements have been built. 8 sets of PZT elements were mounted onto the reinforcement bars in an optimized way to form an active sensing diagnostic system. A 90 kHz 5-cycle Hanning-windowed tone burst was used as input. Multiple cracks have been generated on the concrete structures. Through the guided bulk waves propagating in the structures from actuators and sensors mounted from different bars, crack damage could be detected clearly. Cases for both single and multiple cracks were tested. Different crack depths from the surface and different crack numbers have been studied. Test result shows that the amplitude of sensor output signals is deceased linearly with a propagating crack, and is decreased exponentially with increased crack numbers. From the study, the active sensing diagnostic system using PZT based smart rebar network shows a promising way to provide concrete crack damage information through the "talk" among sensors.

  7. Service-life prediction of reinforced concrete structures in subsurface environment

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Ki Jung; Jung, Hae Ryong; Park, Joo Wan [Korea Radioactive Waste Agency, Daejeon (Korea, Republic of)

    2016-03-15

    This paper focuses on the estimation of durability and service-life of reinforced concrete structures in Wolsong Low- and intermediate-level wastes Disposal Center (WLDC) in Korea. There are six disposal silos located in the saturated environment. The silo concrete is degraded due to reactions with groundwater and chemical attacks, and finally it will lose its properties as a transport barrier. The infiltration of sulfate and magnesium, leaching of potassium hydroxide, and chlorine induced corrosion are the most significant factors for degradation of reinforced concrete structure in underground environment. From the result of evaluation of the degradation time for each factor, the degradation rate of the reinforced concrete due to sulfate and magnesium is 1.308×10{sup -3} cm/yr, and it is estimated to take 48,000 years for full degradation while potassium hydroxide is leached in depth of less than 1.5 cm at 1,000 years after the initiation of degradation. In case of chlorine induced corrosion, it takes 1,648 years to initiate corrosion in the main reinforced bar and 2,288 years to reach the lifetime limit of the structural integrity, and thus it is evaluated as the most significant factor.

  8. The Carnegie-Irvine Galaxy Survey. V. Statistical Study of Bars and Buckled Bars

    Science.gov (United States)

    Li, Zhao-Yu; Ho, Luis C.; Barth, Aaron J.

    2017-08-01

    Simulations have shown that bars are subject to a vertical buckling instability that transforms thin bars into boxy or peanut-shaped structures, but the physical conditions necessary for buckling to occur are not fully understood. We use the large sample of local disk galaxies in the Carnegie-Irvine Galaxy Survey to examine the incidence of bars and buckled bars across the Hubble sequence. Depending on the disk inclination angle (I), a buckled bar reveals itself as either a boxy/peanut-shaped bulge (at high I) or as a barlens structure (at low I). We visually identify bars, boxy/peanut-shaped bulges, and barlenses, and examine the dependence of bar and buckled bar fractions on host galaxy properties, including Hubble type, stellar mass, color, and gas mass fraction. We find that the barred and unbarred disks show similar distributions in these physical parameters. The bar fraction is higher (70%-80%) in late-type disks with low stellar mass (M * 1010.5 M ⊙), and decreases with higher gas mass ratio. These results suggest that bars are more difficult to grow in massive disks that are dynamically hotter than low-mass disks. However, once a bar forms, it can easily buckle in the massive disks, where a deeper potential can sustain the vertical resonant orbits. We also find a probable buckling bar candidate (ESO 506-G004) that could provide further clues to understand the timescale of the buckling process.

  9. Full scale model push-off test of reinforced concrete block with 51 mm dia. deformed steel bars

    International Nuclear Information System (INIS)

    Aoyagi, Y.

    1981-01-01

    The conclusions of this study are as follows; (1) The equation previously derived from small scale specimens, to predict the shear strength of push-off specimens including both initially cracked and uncracked, can conservatively estimate the experimental data of full scale specimens to the same extent as small scale ones. (2) The equation previously derived from small scale specimens, to predict the shear strength of initially cracked push-off specimens with reinforcements inclined to the shear plane, agrees reasonably well with the experimental data of full scale speciemens. (3) The concrete strength and yield strength of reinforcement theoretically set the balanced reinforcement ratio of the shear area above which the shear strength of specimens is constant. (4) The theoretical shear strength of push-off specimens overestimates the experimental data by about 25%. (orig./HP)

  10. The Carnegie-Irvine Galaxy Survey. V. Statistical Study of Bars and Buckled Bars

    Energy Technology Data Exchange (ETDEWEB)

    Li, Zhao-Yu [Key Laboratory for Research in Galaxies and Cosmology, Shanghai Astronomical Observatory, Chinese Academy of Science, 80 Nandan Road, Shanghai 200030 (China); Ho, Luis C. [Kavli Institute for Astronomy and Astrophysics, Peking University, Beijing 100871 (China); Barth, Aaron J., E-mail: lizy@shao.ac.cn [Department of Physics and Astronomy, 4129 Frederick Reines Hall, University of California, Irvine, CA, 92697-4575 (United States)

    2017-08-10

    Simulations have shown that bars are subject to a vertical buckling instability that transforms thin bars into boxy or peanut-shaped structures, but the physical conditions necessary for buckling to occur are not fully understood. We use the large sample of local disk galaxies in the Carnegie-Irvine Galaxy Survey to examine the incidence of bars and buckled bars across the Hubble sequence. Depending on the disk inclination angle ( i ), a buckled bar reveals itself as either a boxy/peanut-shaped bulge (at high i ) or as a barlens structure (at low i ). We visually identify bars, boxy/peanut-shaped bulges, and barlenses, and examine the dependence of bar and buckled bar fractions on host galaxy properties, including Hubble type, stellar mass, color, and gas mass fraction. We find that the barred and unbarred disks show similar distributions in these physical parameters. The bar fraction is higher (70%–80%) in late-type disks with low stellar mass ( M {sub *} < 10{sup 10.5} M {sub ⊙}) and high gas mass ratio. In contrast, the buckled bar fraction increases to 80% toward massive and early-type disks ( M {sub *} > 10{sup 10.5} M {sub ⊙}), and decreases with higher gas mass ratio. These results suggest that bars are more difficult to grow in massive disks that are dynamically hotter than low-mass disks. However, once a bar forms, it can easily buckle in the massive disks, where a deeper potential can sustain the vertical resonant orbits. We also find a probable buckling bar candidate (ESO 506−G004) that could provide further clues to understand the timescale of the buckling process.

  11. Decays of Higgs bosons to bb-bar, ττ-bar, and cc-bar as signatures of supersymmetry and CP phases

    International Nuclear Information System (INIS)

    Ibrahim, Tarek; Nath, Pran

    2003-01-01

    The branching ratio of the lightest Higgs boson decay into bb(bar sign), ττ-bar and cc-bar is sensitive to supersymmetric effects. We include in this work the effects of CP phases on the Higgs boson decays. Specifically we compute the deviation of the CP phase dependent branching ratio from the standard model result. The analysis includes the full one loop corrections of fermion masses including CP phases involving the gluino, the chargino and the neutralino exchanges. The analysis shows that the supersymmetric effects with CP phases can change the branching ratios by as much as 100% for the lightest Higgs boson decay into bb(bar sign) and ττ-bar with similar results holding for the heavier Higgs boson decays. A detailed analysis is also given for the effects of CP phases on the Higgs boson decays into cc-bar. The deviations of R b/τ and R b/c from the standard model result are investigated as a possible signature of supersymmetry and CP effects. Thus a measurement of the decays of the Higgs boson into bb-bar, ττ-bar and cc-bar may provide important clues regarding the existence of supersymmetry and CP phases

  12. Multi-sensor system for in situ shape monitoring and damage identification of high-speed composite rotors

    Science.gov (United States)

    Philipp, K.; Filippatos, A.; Kuschmierz, R.; Langkamp, A.; Gude, M.; Fischer, A.; Czarske, J.

    2016-08-01

    Glass fibre-reinforced polymer (GFRP) composites offer a higher stiffness-to-weight ratio than conventional rotor materials used in turbomachinery. However, the material behaviour of GFRP high-speed rotors is difficult to predict due to the complexity of the composite material and the dynamic loading conditions. Consequently dynamic expansion measurements of GRFP rotors are required in situ and with micron precision. However, the whirling motion amplitude is about two orders of magnitude higher than the desired precision. To overcome this problem, a multi-sensor system capable of separating rotor expansion and whirling motion is proposed. High measurement rates well above the rotational frequency and micron uncertainty are achieved at whirling amplitudes up to 120μm and surface velocities up to 300 m/s. The dynamic elliptical expansion of a GFRP rotor is investigated in a rotor loading test rig under vacuum conditions. In situ measurements identified not only the introduced damage but also damage initiation and propagation.

  13. Reliability algorithms applied to reinforced concrete structures durability assessment

    Directory of Open Access Journals (Sweden)

    C. G. Nogueira

    Full Text Available This paper addresses the analysis of probabilistic corrosion time initiation in reinforced concrete structures exposed to ions chloride penetration. Structural durability is an important criterion which must be evaluated in every type of structure, especially when these structures are constructed in aggressive atmospheres. Considering reinforced concrete members, chloride diffusion process is widely used to evaluate the durability. Therefore, at modelling this phenomenon, corrosion of reinforcements can be better estimated and prevented. These processes begin when a threshold level of chlorides concentration is reached at the steel bars of reinforcements. Despite the robustness of several models proposed in the literature, deterministic approaches fail to predict accurately the corrosion time initiation due to the inherently randomness observed in this process. In this regard, the durability can be more realistically represented using probabilistic approaches. A probabilistic analysis of ions chloride penetration is presented in this paper. The ions chloride penetration is simulated using the Fick's second law of diffusion. This law represents the chloride diffusion process, considering time dependent effects. The probability of failure is calculated using Monte Carlo simulation and the First Order Reliability Method (FORM with a direct coupling approach. Some examples are considered in order to study these phenomena and a simplified method is proposed to determine optimal values for concrete cover.

  14. Fibre Bragg grating sensors for reinforcement corrosion monitoring in civil engineering structures

    International Nuclear Information System (INIS)

    Grattan, S K T; Basheer, P; Taylor, S E; Zhao, W; Sun, T; Grattan, K T V

    2007-01-01

    Fibre optic strain sensors offer a number of advantages over the current electrical resistance type gauges, yet are not widely used in civil engineering applications. The use of fibre optic strain sensors (with a cross comparison with the output of electrical resistance gauges) to monitor the production of corrosion by-products in civil engineering concrete structures containing reinforcement bars has been investigated and results reported

  15. Finite element analysis of smart reinforced concrete beam with super elastic shape memory alloy subjected to static loading for seismic mitigation

    Science.gov (United States)

    Hamid, Nubailah Abd; Ismail, Muhammad Hussain; Ibrahim, Azmi; Adnan, Azlan

    2018-05-01

    Reinforced concrete beam has been among major applications in construction nowadays. However, the application of nickel titanium alloy as a replacement for steel rebar in reinforced concrete beam is a new approach nowadays despite of their ability to undergo large deformations and return to their undeformed shape by removal of stresses. In this paper, the response of simply supported reinforced concrete (RC) beams with smart rebars, control beam subjected to static load has been numerically studied, and highlighted, using finite element method (FEM) where the material employed in this study is the superelastic shape memory alloys (SESMA). The SESMA is a unique alloy that has the ability to undergo large deformations and return to their undeformed shape by removal of stresses. The size of the analysed beam is 125 mm × 270 mm × 2800 mm with 2 numbers of 12 mm diameter bars as main reinforcement for compression and 12 numbers of 12 as tension or hanger bars while 6 mm diameter at 100 mm c/c used as shear reinforcement bars respectively. The concrete was modelled using solid 65 element (in ANSYS) and rebars were modelled using beam 188 elements (in ANSYS). The result for reinforced concrete with nickel titanium alloy rebar is compared with the result obtained for reinforced concrete beam with steel rebar in term of flexural behavior, load displacement relationship, crack behaviour and failure modes for various loading conditions starting from 10kN to 100kN using 3D FE modelling in ANSYS v 15. The response and result obtained from the 3D finite element analysis used in this study is load-displacement curves, residual displacements, Von-Misses, strain and stiffness are suitable for the corresponding result showed a satisfactory performance in the structural analysis. Resultant displacement, Von-Mises stress and maximum strain were influenced by the factors of the material properties, load increments and the mesh size. Nickel titanium alloy was superior to the

  16. Studying W‧ boson contributions in \\bar{B} \\rightarrow {D}^{(* )}{{\\ell }}^{-}{\\bar{\

    Science.gov (United States)

    Wang, Yi-Long; Wei, Bin; Sheng, Jin-Huan; Wang, Ru-Min; Yang, Ya-Dong

    2018-05-01

    Recently, the Belle collaboration reported the first measurement of the τ lepton polarization P τ (D*) in \\bar{B}\\to {D}* {τ }-{\\bar{ν }}τ decay and a new measurement of the rate of the branching ratios R(D*), which are consistent with the Standard Model (SM) predictions. These could be used to constrain the New Physics (NP) beyond the SM. In this paper, we probe \\bar{B}\\to {D}(* ){{\\ell }}-{\\bar{ν }}{\\ell } (ℓ = e, μ, τ) decays in the model-independent way and in the specific G(221) models with lepton flavour universality. Considering the theoretical uncertainties and the experimental errors at the 95% C.L., we obtain the quite strong bounds on the model-independent parameters {C}{{LL}}{\\prime },{C}{{LR}}{\\prime },{C}{{RR}}{\\prime },{C}{{RL}}{\\prime },{g}V,{g}A,{g}V{\\prime },{g}A{\\prime } and the specific G(221) model parameter rates. We find that the constrained NP couplings have no obvious effects on all (differential) branching ratios and their rates, nevertheless, many NP couplings have very large effects on the lepton spin asymmetries of \\bar{B}\\to {D}(* ){{\\ell }}-{\\bar{ν }}{\\ell } decays and the forward–backward asymmetries of \\bar{B}\\to {D}* {{\\ell }}-{\\bar{ν }}{\\ell }. So we expect precision measurements of these observables would be researched by LHCb and Belle-II.

  17. Study of the {rho}-bar, {beta}-bar and {lambda} parameters of a light-water reactor; Etude des parametres {rho}-bar, {beta}-bar et {lambda} d'une pile a eau legere

    Energy Technology Data Exchange (ETDEWEB)

    Riche, R [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1965-09-01

    The kinetic and perturbation equations are derived from the time-dependent transport equation. Kinetic equations depend only on the ratios a = {rho}-bar/{beta}-bar and b = {beta}-bar/{lambda}, which are definite, while the reactivity {rho}-bar, the delayed neutron fraction ({beta}-bar and the generation time {lambda} are expressed in terms of an arbitrary function I. The 'static' definitions of these parameters, which reduce kinetic problems to a set of purely term dependent equations, introduce the effective fraction {beta}-bar. One way of determining experimentally the ratio b is presented; it consists in analysing the power transient after a rapid variation of the reactivity, caused by the implosion of an empty glass-bull. A simple interpretation is proposed. The apparatus can be transformed easily into a reactimeter. The value of the effective delayed neutron fraction {beta}-bar has been determined by averaging the reactivity effects of a copper sheet through out the reactor core. Experimental results: b = {beta}-bar/{lambda} = 129 s{sup -1} and {beta}-bar 795.10{sup -5}, have been determined on a light-water moderated, enriched-uranium fuelled reactor. The calculated values of the effectiveness of delayed neutrons {gamma} {beta}-bar/{beta} 1.23 and the generation time {lambda} 59.10{sup -6}s agrees fairly well with the experimental results. (author) [French] Les equations de la cinetique et de la perturbation sont deduites de la theorie du transport, par l'intermediaire de la 'notion' d'importance des neutrons. La cinetique ne depend que des rapports a = {rho}-bar/{beta}-bar et b = {beta}-bar/{lambda}, qui sont parfaitement definis; par contre, la reactivite {rho}-bar, la proportion de neutrons retardes {beta}-bar et le temps de generation des neutrons prompts {lambda} s'expriment a l'aide d'une meme fonction arbitraire I. Les definitions 'statiques' de ces parametres, qui permettent de rendre compte de la cinetique par des equations dependant purement du

  18. Observations on the electrical resistivity of steel fibre reinforced concrete

    DEFF Research Database (Denmark)

    Solgaard, Anders Ole Stubbe; Geiker, Mette Rica; Edvardsen, Carola

    2014-01-01

    concrete the model underestimated the influence of the addition of fibres. The results indicate that the addition of steel fibres reduce the electrical resistivity of concrete if the fibres are conductive. This represents a hypothetical case where all fibres are depassivated (corroding) which was created......Steel fibre reinforced concrete (SFRC) is in many ways a well-known construction material, and its use has gradually increased over the last decades. The mechanical properties of SFRC are well described based on the theories of fracture mechanics. However, knowledge on other material properties......, including the electrical resistivity, is sparse. Among others, the electrical resistivity of concrete has an effect on the corrosion process of possible embedded bar reinforcement and transfer of stray current. The present paper provides experimental results concerning the influence of the fibre volume...

  19. Joint model to simulate inelastic shear behavior of poorly detailed exterior and interior beam-column connections reinforced with deformed bars under seismic excitations

    International Nuclear Information System (INIS)

    Sharma, Akanshu; Reddy, G.R.; Vaze, K.K.; Ghosh, A.K.; Kushwaha, H.S.; Eligehausen, Rolf

    2009-12-01

    A model for predicting the nonlinear shear behaviour of reinforced concrete beam column joints based on principal stresses reaching limits is proposed. The joint model proposes shear springs for the column region and rotational spring for the beam region of the joint. This is based on the actual displacement behaviour of the shear buildings. The spring characteristics are calculated based on well-known principal of mechanics using the principal stresses as the failure criteria. The model reasonably accurately predicts the shear behaviour of the joint and also can consider the effect of axial loads on the column. The model does not need any special element or special program for implementation and can be used for nonlinear static pushover analysis of RC framed structures giving due consideration to joint deformations. The model is therefore extremely useful for practical displacement based analysis of old RC buildings where the joints were not designed and detailed as per current codal requirements, invariably making them the weakest link in the structure. The background theory, assumptions followed and the complete formulations for generating the joint characteristics are given in this report. The model is validated with experimental results of tests on exterior and interior beam-column connections given in the published literature having substandard detailing using deformed bars. (author)

  20. H-bar and H-bar + production cross sections for the GBAR experiment

    International Nuclear Information System (INIS)

    Comini, P; Hervieux, P-A

    2013-01-01

    The production and cooling of the H-bar + ion is the key point of the GBAR experiment (Gravitational Behaviour of Antihydrogen at Rest), which aims at performing the free fall of antihydrogen atoms to measure g-bar , the acceleration of antimatter on Earth. H-bar + ions will be obtained from collisions between a positronium cloud and antiprotons delivered by the AD/ELENA facility at CERN, with intermediate formation of antihydrogen atoms. In order to optimise the experimental production of H-bar + ions, we computed the total cross sections of the two corresponding reactions, within the same theoretical framework of the Continuum Distorted Wave – Final State (CDW-FS) model. The different contributions of the H-bar excited states have been systematically investigated for different states of Ps. The results exhibit an increase of the H-bar production toward low kinetic energies, in agreement with experimental data and previous calculations, whereas the largest H-bar + production is obtained with low energy ground-state antihydrogen atoms. These theoretical predictions suggest that the overall production of H-bar + could be optimal for 2 keV antiproton impact energy, using positronium atoms prepared in the 2p state.

  1. Load deformation characteristics of GFRP reinforced HPC square ...

    African Journals Online (AJOL)

    Journal of Civil Engineering Research and Practice. Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives · Journal Home > Vol 7, No 2 (2010) >. Log in or Register to get access to full text downloads.

  2. K-bar-mesic nuclei

    International Nuclear Information System (INIS)

    Dote, Akinobu; Akaishi, Yoshinori; Yamazaki, Toshimitsu

    2005-01-01

    New nuclei 'K-bar-Mesic Nuclei' having the strangeness are described. At first it is shown that the strongly attractive nature of K-bar N interaction is reasoned inductively from consideration of the relation between Kaonic hydrogen atom and Λ (1405) which is an excited state of hyperon Λ. The K-bar N interactions are reviewed and summarized into three categories: 1. Phenomenological approach with density dependent K-bar N interaction (DD), relativistic mean field (RMF) approach, and hybrid of them (RMF+DD). 2. Boson exchange model. 3. Chiral SU(3) theory. The investigation of some light K-bar-nuclei by Akaishi and Yamazaki using phenomenological K-bar N interaction is explained in detail. Studies by antisymmetrized molecular dynamics (AMD) approach are also presented. From these theoretical researches, the following feature of K-bar-mesic nuclei are revealed: 1) Ground state is discrete and bound by 100 MeV or more. 2) Density is very high in side the K-bar-mesic nuclei. 3) Strange structures develop which are not seen in ordinary nuclei. Finally some recent experiments to explore K-bar-mesic nuclei are reviewed. (S. Funahashi)

  3. Warpage Analysis of Electroplated Cu Films on Fiber-Reinforced Polymer Packaging Substrates

    Directory of Open Access Journals (Sweden)

    Cheolgyu Kim

    2015-06-01

    Full Text Available This paper presents a warpage analysis method that predicts the warpage behavior of electroplated Cu films on glass fiber-reinforced polymer (GFRP packaging substrates. The analysis method is performed using the following sequence: fabricate specimens for scanning 3D contours, transform 3D data into curvatures, compute the built-in stress of the film using a stress-curvature analytic model, and verify it through comparisons of the finite element method (FEM simulations with the measured data. The curvature is used to describe the deflection and warpage modes and orientations of the specimen. Two primary factors that affect the warpage behavior of the electroplated Cu film on FRP substrate specimens are investigated. The first factor is the built-in stress in a Cu film that explains the room temperature warpage of the specimen under no thermal process. The second factor is the misfit of the coefficient of thermal expansion (CTE between the Cu and FRP layer, which is a dominant factor during the temperature change. The calculated residual stress, and predicted curvatures using FEM simulation throughout the reflow process temperature range between 25 and 180 °C are proven to be accurate by the comparison of the FEM simulations and experiment measurements.

  4. New Trends for Reinforced Concrete Structures: Some Results of Exploratory Studies

    Directory of Open Access Journals (Sweden)

    Ricardo N. F. Carmo

    2017-10-01

    Full Text Available Today, the concrete sector is being pushed to innovate in order to better address current challenges with higher competitiveness and more sustainable solutions. Different research studies have been conducted all over the world in which novel approaches and paths were proposed. It is important to spread information to define new strategies for the future of this industry. The enhancement of concrete properties and the impact of these changes in structural design are some of the topics analysed in those studies. This paper presents four experimental studies conducted by the authors where different types of concrete and structural members were tested. The common goal of these studies was to develop innovative solutions with high performance and low environmental impact. The scope of the first study was the structural behaviour of members produced with lightweight aggregate concrete (LWAC. Results of several beams, ties, and slabs are herein presented and analysed. The advantage of using glass fibre–reinforced polymer (GFRP rebars was addressed in a second study, and main results obtained with this type of rebar are also herein presented. Recent advances in nanotechnology led to the development of concretes incorporating nanoparticles into the binder matrix. Typically, these nanoparticles have a diameter of 10–300 nanometers and are added to the mixture to reduce the porosity and increase the density of the binder matrix, improving the mechanical properties and durability. To analyse their influence on steel-to-concrete bonding and on the shear and flexural behaviour of the beams was the main goal of the third study herein described. Finally, a new concept to produce reinforced concrete members with high durability using a special concrete cover, which was the goal of the fourth study, is also herein presented.

  5. Dismantling of a hot cell-block and the treatment of the produced concrete bars

    International Nuclear Information System (INIS)

    Rompf, U.; Brielmayer, M.; Graf, A.; Stutz, U.; Ambos, F.

    2003-01-01

    A building with hot cells had been operated in Karlstein/Main from 1968 to 1989 in order to perform check-ups at radiated fuel rods and nuclear components. The operation of the system was stopped after an operation period of approximately 20 years. The core part of the building to be disassembled is a U-shaped hot cell-block with nine individual cells, partly consisting of heavy reinforced concrete, located in the ground floor (fig. 1 and fig. 2). The major part of the cells was covered with 10 mm steel plate and provided with approx. 1,400 openings of all different kinds. The wall thickness of the cells was between 0.90 m and 1.10 m. Under these conditions a successful decontamination at the ''existing building structure'' was not possible. Therefore, the non-supporting structures of the hot cell-block were removed in individual blocks by means of sawing and the remaining walls and floors were peeled by using the diamond rope sawing technique. The dismantling took 17 months. A re-treatment of the produced concrete blocks (235 blocks, approx. 970 Mg) to reduce the radioactive waste to a minimum was performed at the Research Centre Karlsruhe, Central Decontamination Department (HDB). The Target of the concrete bar treatment at HDB is to reduce the volume of radioactive waste to a minimum and to add the major part of the concrete bars to harmless utilisation. To achieve the same, initially the more contaminated parts of the bars without openings, such as tubes, cable or ventilating shafts, are removed by means of wire cutting and packed into a KONRAD-Container as radioactive waste. The remaining bar is decontaminated by means of sandblasting and afterwards, following successful release measurement, released from the scope of the regulations under the Atomic Energy. Bars with openings are crushed into small pieces by means of the remote-controlled chisel excavator, in order to separate the individual kinds of material. The rubble is packed into drums and measured by

  6. Double-Sided Terahertz Imaging of Multilayered Glass Fiber-Reinforced Polymer

    Directory of Open Access Journals (Sweden)

    Przemyslaw Lopato

    2017-06-01

    Full Text Available Polymer matrix composites (PMC play important roles in modern industry. Increasing the number of such structures in aerospace, construction, and automotive applications enforces continuous monitoring of their condition. Nondestructive inspection of layered composite materials is much more complicated process than evaluation of homogenous, (mostly metallic structures. Several nondestructive methods are utilized in this case (ultrasonics, shearography, tap testing, acoustic emission, digital radiography, infrared imaging but none of them gives full description of evaluated structures. Thus, further development of NDT techniques should be studied. A pulsed terahertz method seems to be a good candidate for layered PMC inspection. It is based on picosecond electromagnetic pulses interacting with the evaluated structure. Differences of dielectric parameters enables detection of a particular layer in a layered material. In the case of multilayered structures, only layers close to surface can be detected. The response of deeper ones is averaged because of multiple reflections. In this paper a novel inspection procedure with a data processing algorithm is introduced. It is based on a double-sided measurement, acquired signal deconvolution, and data combining. In order to verify the application of the algorithm stress-subjected glass fiber-reinforced polymer (GFRP was evaluated. The obtained results enabled detection and detailed analysis of delaminations introduced by stress treatment and proved the applicability of the proposed algorithm.

  7. Bar-tailed

    NARCIS (Netherlands)

    Duijns, S.; Hidayati, N.A.; Piersma, T.

    2013-01-01

    Capsule Across the European wintering range Bar-tailed Godwits Limosa lapponica lapponica selected polychaete worms and especially Ragworms Hediste diversicolor, with differences between areas due to variations in prey availability.Aims To determine the diet of Bar-tailed Godwits across their

  8. Possible heavy tetraquarks qQq-barQ-bar, qqQ-barQ-bar and qQQ-barQ-bar

    International Nuclear Information System (INIS)

    Cui Ying; Chen Xiaolin; Deng Weizhen; Zhu Shilin

    2007-01-01

    Assuming X(3872) is a qcq-barc-bar tetraquark and using its mass as input, the authors perform a schematic study of the masses of possible heavy tetraquarks using the color-magnetic interaction with the flavor symmetry breaking corrections. (authors)

  9. Development of structural health monitoring and early warning system for reinforced concrete system

    International Nuclear Information System (INIS)

    Iranata, Data; Wahyuni, Endah; Murtiadi, Suryawan; Widodo, Amien; Riksakomara, Edwin; Sani, Nisfu Asrul

    2015-01-01

    Many buildings have been damaged due to earthquakes that occurred recently in Indonesia. The main cause of the damage is the large deformation of the building structural component cannot accommodate properly. Therefore, it is necessary to develop the Structural Health Monitoring System (SHMS) to measure precisely the deformation of the building structural component in the real time conditions. This paper presents the development of SHMS for reinforced concrete structural system. This monitoring system is based on deformation component such as strain of reinforcement bar, concrete strain, and displacement of reinforced concrete component. Since the deformation component has exceeded the limit value, the warning message can be sent to the building occupies. This warning message has also can be performed as early warning system of the reinforced concrete structural system. The warning message can also be sent via Short Message Service (SMS) through the Global System for Mobile Communications (GSM) network. Hence, the SHMS should be integrated with internet modem to connect with GSM network. Additionally, the SHMS program is verified with experimental study of simply supported reinforced concrete beam. Verification results show that the SHMS has good agreement with experimental results

  10. On Modified Bar recursion

    DEFF Research Database (Denmark)

    Oliva, Paulo Borges

    2002-01-01

    Modified bar recursion is a variant of Spector's bar recursion which can be used to give a realizability interpretation of the classical axiom of dependent choice. This realizability allows for the extraction of witnesses from proofs of forall-exists-formulas in classical analysis. In this talk I...... shall report on results regarding the relationship between modified and Spector's bar recursion. I shall also show that a seemingly weak form of modified bar recursion is as strong as "full" modified bar recursion in higher types....

  11. 53rd Concrete Technology Conference. Repair, Reinforcement 3; Dai 53 kai semento gijutsu taikai. Hoshu, hokyo 3

    Energy Technology Data Exchange (ETDEWEB)

    Wakasugi, Mikio

    1999-08-10

    Yanagi et al. investigated crack-blocking effect of salt-removing effect of electrodeposition method using a ZnSO{sub 4} solution. Nishida et al. also paid attention to the same method, and carried out the investigation by applying the electrodeposition method using two kinds of solutions, i.e., ZnSO{sub 4} solution and MgCl{sub 2} solution, to samples where dry shrinkage and cracks are generated, then observing crack-blocking state and improvement state of mortar interior with a SEM and measuring pore size distribution. Fukushima carried out theoretical analysis in respect to the effect of surface finishing treatment in concrete to perform neutralization until the backs of reinforcing bars upon the corrosion inhibition of the reinforcing bars. Kubo et al. direct their attention to 100% silane without using any organic solvent, specifically, they used five kinds of silane with different molecular weight and molecular structure, performed surface treatment of concretes with different moisture state and density-solid state and measured moisture permeability and water permeability. Ueki et al. proposed a method for evaluating fluidity of high-flow mortar used in steel plate-lining operation of anti-earthquake reinforcing works, namely, a new testing method using a device for pouring high-flow mortar into a certain-spaced clearance from J funnel. (NEDO)

  12. Load carrying capacity of keyed joints reinforced with high strength wire rope loops

    DEFF Research Database (Denmark)

    Jørgensen, Henrik B.; Hoang, Linh Cao

    2015-01-01

    friendly shear connection can be obtained by replacing the U-bars with high strength looped wire ropes. The wire ropes have the advantage of being flexible (they have virtually no bending stiffness) which makes installation of wall elements much easier. The looped wire ropes are usually pre-installed in so......-called wire boxes which are embedded in the precast wall elements. Once the joint is grouted with mortar, the boxes will function as shear keys and the overlapping wire loops will function as transverse reinforcement that replaces the U-bars. This paper presents a rigid-plastic upper bound model to determine...... the shear capacity of wire loop connections. Tests have shown that the shear capacity of such joints – due to the relatively high tensile strength of the wire ropes - is more prone to be governed by fracture of the joint mortar in combination with yielding of the locking bar. To model this type of failure...

  13. The bridge technique for pectus bar fixation: a method to make the bar un-rotatable.

    Science.gov (United States)

    Park, Hyung Joo; Kim, Kyung Soo; Moon, Young Kyu; Lee, Sungsoo

    2015-08-01

    Pectus bar rotation is a major challenge in pectus repair. However, to date, no satisfactory technique to completely eliminate bar displacement has been introduced. Here, we propose a bar fixation technique using a bridge that makes the bar unmovable. The purpose of this study was to determine the efficacy of this bridge technique. A total of 80 patients underwent pectus bar repair of pectus excavatum with the bridge technique from July 2013 to July 2014. The technique involved connecting 2 parallel bars using plate-screws at the ends of the bars. To determine bar position change, the angles between the sternum and pectus bars were measured on postoperative day 5 (POD5) and 4 months (POM4) and compared. The mean patient age was 17.5 years (range, 6-38 years). The mean difference between POD5 and POM4 were 0.23° (P=.602) and 0.35° (P=.338) for the upper and lower bars, respectively. Bar position was virtually unchanged during the follow-up, and there was no bar dislocation or reoperation. A "bridge technique" designed to connect 2 parallel bars using plates and screws was demonstrated as a method to avoid pectus bar displacement. This approach was easy to implement without using sutures or invasive devices. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Search for W→cs-bar, Z→cc-bar,bb-bar in muon-jet events at the CERN proton-antiproton collider

    International Nuclear Information System (INIS)

    Ransdell, J.

    1988-01-01

    A search for quark decays of the W and Z particles produced in proton-antiproton collisions at √s of 630 GeV in the UA1 experiment at the CERN collider is described. The search was made in the channels W→cs-bar, Z→cc-bar,bb-bar where b and c quarks were identified by the presence of a high-p/sub T/ muon in or near a jet. Although these decay channels avoid the copious background of QCD produced light quark and gluon jets, it was not possible to detect a W or Z signal because of the large cross section for strong cc-bar and bb-bar production

  15. Experimental study of nylon fibre reinforced RC beams

    International Nuclear Information System (INIS)

    Ansari, A.A.; Jokhio, S.; Qazi, Attiq-ur-Rehman

    2002-01-01

    Six concrete beams reinforced with Nylon fibre strands placed in tensile zone as an alternative of steel bars have been tested. Fibre of 1.2 mm dia was used and 10 pieces were twisted together to form the strand; the number of turns being a parameter of study. This was done in order to over come the problem of bond, because the surface of fibre is very smooth and slippery. Two strands were used in each beam and in order to eliminate possibility of premature failure due to bond, specially designed End-Steel Anchorages were also tried. All the beams were 1000 mm long and 50 x 100 mm in cross section with an affective span of 900 mm. The tensile behaviors as well as moduli of the fibre itself were also determined. No shear reinforcement was used. The results are encourage and comparative financial study shows that this material holds promise for future use. However, more experimental study is needed. (author)

  16. Study of the {rho}-bar, {beta}-bar and {lambda} parameters of a light-water reactor; Etude des parametres {rho}-bar, {beta}-bar et {lambda} d'une pile a eau legere

    Energy Technology Data Exchange (ETDEWEB)

    Riche, R. [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1965-09-01

    The kinetic and perturbation equations are derived from the time-dependent transport equation. Kinetic equations depend only on the ratios a = {rho}-bar/{beta}-bar and b = {beta}-bar/{lambda}, which are definite, while the reactivity {rho}-bar, the delayed neutron fraction ({beta}-bar and the generation time {lambda} are expressed in terms of an arbitrary function I. The 'static' definitions of these parameters, which reduce kinetic problems to a set of purely term dependent equations, introduce the effective fraction {beta}-bar. One way of determining experimentally the ratio b is presented; it consists in analysing the power transient after a rapid variation of the reactivity, caused by the implosion of an empty glass-bull. A simple interpretation is proposed. The apparatus can be transformed easily into a reactimeter. The value of the effective delayed neutron fraction {beta}-bar has been determined by averaging the reactivity effects of a copper sheet through out the reactor core. Experimental results: b = {beta}-bar/{lambda} = 129 s{sup -1} and {beta}-bar 795.10{sup -5}, have been determined on a light-water moderated, enriched-uranium fuelled reactor. The calculated values of the effectiveness of delayed neutrons {gamma} {beta}-bar/{beta} 1.23 and the generation time {lambda} 59.10{sup -6}s agrees fairly well with the experimental results. (author) [French] Les equations de la cinetique et de la perturbation sont deduites de la theorie du transport, par l'intermediaire de la 'notion' d'importance des neutrons. La cinetique ne depend que des rapports a = {rho}-bar/{beta}-bar et b = {beta}-bar/{lambda}, qui sont parfaitement definis; par contre, la reactivite {rho}-bar, la proportion de neutrons retardes {beta}-bar et le temps de generation des neutrons prompts {lambda} s'expriment a l'aide d'une meme fonction arbitraire I. Les definitions 'statiques' de ces parametres, qui permettent de rendre compte de la

  17. On the Relation between Spector's Bar Recursion and Modified Bar Recursion

    DEFF Research Database (Denmark)

    Oliva, Paulo Borges

    2002-01-01

    We introduce a variant of Spector's Bar Recursion in finite types to give a realizability interpretation of the classical axiom of dependent choice allowing for the extraction of witnesses from proofs of Sigma_1 formulas in classical analysis. We also give a bar recursive definition of the fan...... functional and study the relationship of our variant of Bar Recursion with others....

  18. Retrofit of hollow concrete masonry infilled steel frames using glass fiber reinforced plastic laminates

    Science.gov (United States)

    Hakam, Zeyad Hamed-Ramzy

    2000-11-01

    This study focuses on the retrofit of hollow concrete masonry infilled steel frames subjected to in-plane lateral loads using glass fiber reinforced plastic (GFRP) laminates that are epoxy-bonded to the exterior faces of the infill walls. An extensive experimental investigation using one-third scale modeling was conducted and consisted of two phases. In the first phase, 64 assemblages, half of which were retrofitted, were tested under various combined in-plane loading conditions similar to those which different regions of a typical infill wall are subjected to. In the second phase, one bare and four masonry-infilled steel frames representative of a typical single-story, single-bay panel were tested under diagonal loading to study the overall behavior and the infill-frame interaction. The relative infill-to-frame stiffness was varied as a test parameter by using two different steel frame sections. The laminates altered the failure modes of the masonry assemblages and reduced the variability and anisotropic nature of the masonry. For the prisms which failed due to shear and/or mortar joint slip, significant strength increases were observed. For those exhibiting compression failure modes, a marginal increase in strength resulted. Retrofitting the infilled frames resulted in an average increase in initial stiffness of two-fold compared to the unretrofitted infilled frames, and seemed independent of the relative infill-to-frame stiffness. However, the increase in the load-carrying capacity of the retrofitted frames compared to the unretrofitted counterparts was higher for those with the larger relative infill-to-frame stiffness parameter. Unlike the unretrofitted infill walls, the retrofitted panels demonstrated almost identical failure modes that were characterized as "strictly comer crushing" in the vicinity of the loaded comers whereas no signs of distress were evident throughout the remainder of the infill. The laminates also maintained the structural integrity of

  19. Study of Rust Effect on the Corrosion Behavior of Reinforcement Steel Using Impedance Spectroscopy

    Science.gov (United States)

    Bensabra, Hakim; Azzouz, Noureddine

    2013-12-01

    Most studies on corrosion of steel reinforcement in concrete are conducted on steel samples with polished surface (free of all oxides) in order to reproduce the same experimental conditions. However, before embedding in concrete, the steel bars are often covered with natural oxides (rust), which are formed during exposure to the atmosphere. The presence of this rust may affect the electrochemical behavior of steel rebar in concrete. In order to understand the effect of rust on the corrosion behavior of reinforcement steel, potentiodynamic and electrochemical impedance spectroscopy (EIS) tests were carried out in a simulated concrete pore solution using steel samples with two different surface conditions: polished and rusted samples. The obtained results have shown that the presence of rust on the steel bar has a negative effect on its corrosion behavior, with or without the presence of chlorides. This detrimental effect can be explained by the fact that the rust provokes a decrease of the electrolyte resistance at the metal-concrete interface and reduces the repassivating ability. In addition, the rust layer acts as a barrier against the hydroxyl ion diffusion, which prevents the realkalinization phenomenon.

  20. PARCS - A pre-stressed and reinforced concrete shell element for analysis of containment structures

    International Nuclear Information System (INIS)

    Buragohain, D.N.; Mukherjee, A.

    1993-01-01

    Containment structures are designed as pressure vessels against a huge internal pressure build up in the event of a postulated LOCA. In such situations the containment structures experience predominantly in-plane stress in tension. Therefore, pre-stressed concrete has been very frequently used for the construction of containment. For larger plants a dual containment with a pre-stressed concrete inner containment and a reinforced concrete outer containment has been adopted. These structures are required to perform within very stringent safety requirements under extremely severe loading. Naturally, their design has attracted a lot of investigators and a huge volume of literature has been published in previous SMiRT conferences. However, it seems that the structural modeling of the containment has not developed accordingly. It is a common practice to consider the concrete section only in the model and the effects of pre-stress and reinforcements are usually neglected. This is due to the difficulty in including these effects without generating an unduly large model. To include these effects using the existing software, the concrete can be modeled with 3D elements. The reinforcements can be included in the model as bar or cable elements. However, that would require a nodal line along every reinforcement. Therefore, this method would generate a huge model unmanageable even with modern computing facilities. Alternatively, the reinforcements can be assumed to be smeared uniformly within the structure and an average property can be included. This model is acceptable when the reinforcements are very closely spaced. However, for sparsely spaced reinforcements it would result in loss of accuracy, especially in important areas like the vicinity of large openings. In this paper a shell element for the analysis of pre-stressed and reinforced concrete structures has been proposed which alleviates this difficulty. This element can accommodate the reinforcing bars or cables anywhere

  1. Fiber-reinforced concretes with a high fiber volume fraction — a look in future. Can a design determine the fiber amount in concrete in real time in every part of a structure in production?

    Science.gov (United States)

    Tepfers, R.

    2010-09-01

    In near future, when the control of the load-bearing capacity of fiber-only-reinforced concrete members will be safely guaranteed, the deletion of the ordinary continuous steel reinforcing bars might be possible. For the time being, it is difficult to change the fiber amount during the casting with today's techniques. Therefore, the fiber concentration has to be determined by the maximum tensile stress in concrete structural members, resulting in an unnecessary fiber addition in compressed zones. However, if the right amount of fibers could be regulated and added to concrete in real time at the pump outlet, a future vision could be to design and produce a structure by using FEM-controlled equipment. The signals from calculation results could be transmitted to a concrete casting system for addition of a necessary amount of fibers to take care of the actual tensile stresses in the right position in the structure. The casting location could be determined by using a GPS for positioning the pump outlet for targeting the casting location horizontally and a laser vertically. The addition of fibers to concrete at the outlet of a concrete pump and proportioning them there according to the actual needs of the stress situation in a structure, given by a FEM analysis in real time, is a future challenge. The FEM analysis has to be based on material properties of fiber-only-reinforced concrete. This means that the resistance and stiffness of different-strength concrete members with a varying fiber content has to be determined in tests and conveyed to the FEM analysis. The FEM analysis has to be completed before the casting and controlled. Then it can be used as the base for adding a correct amount of fibers to concrete in every part of the structure. Thus, a system for introducing a correct amount of fibers into concrete has to be developed. The fibers have to be added at the outlet of concrete pump. Maybe a system to shotcrete concrete with electronically controlled fiber

  2. Dynamics of a stellar bar

    International Nuclear Information System (INIS)

    Miller, R.H.; Smith, B.F.

    1979-01-01

    The dynamical properties of a prolate bar have been studied by means of a three-dimensional computer model. The bar pattern rotates in the sense of the total angular momentum. The mean particle motion is a rapid streaming in the direction of pattern rotation as seen from a frame that rotates with the bar. Rotation rates that would be inferred from observation are significantly (2--3 times) faster than the pattern rotation speed. Velocity dispersions are anisotropic with the largest component along the bar. Particles oscillate in the bar potential significantly faster than pattern rotation: typical oscillation frequencies are around ω/sub z/=ω/sub y/=6Ω and ω/sub x/=3Ω where z is the direction of angular momentum, x lies along the bar, and Ω is the pattern angular velocity. About 25% of the star orbits are near 2:2:1 resonance with the slow motion along the bar. Particle motion is highly ordered in the bar:the ratio t=T/sub mean//vertical-barWvertical-bar is 0.21--0.24. Observable properties are described; where comparisons can be made, observable properties are in agreement with observations of brightness contours, velocity fields, and velocity dispersions. The bar has nearly exponential density profiles

  3. New results from Fermilab E866 (NuSea) for d-bar/u-bar

    International Nuclear Information System (INIS)

    Isenhower, L. D.

    1999-01-01

    The Fermilab dimuon experiment 866/NuSea measured Drell-Yan yields from an 800 GeV/c proton beam incident on liquid hydrogen and deuterium targets. Over 370,000 Drell-Yan muon pairs were recorded. From these data, the ratio of anti-down (d-bar) to anti-up (u-bar) quark distributions in the proton sea is determined over a wide range in Bjorken-x. A strong x dependence is observed in the ratio d-bar/u-bar, showing substantial enhancement of d-bar with respect to u-bar for x < 0.2. The results presented here for the full data sets confirm previously published results from E866 and are compared with parametrizations of parton distribution functions calculated both before and after the publication of the high-mass E866 data

  4. Impartial Triangular Chocolate Bar Games

    OpenAIRE

    Miyadera, Ryohei; Nakamura, Shunsuke; Fukui, Masanori

    2017-01-01

    Chocolate bar games are variants of the game of Nim in which the goal is to leave your opponent with the single bitter part of the chocolate bar. The rectangular chocolate bar game is a thinly disguised form of classical multi-heap Nim. In this work, we investigate the mathematical structure of triangular chocolate bar games in which the triangular chocolate bar can be cut in three directions. In the triangular chocolate bar game, a position is a $\\mathcal{P}$-position if and only if $x \\oplu...

  5. Test of bar window with internal bars free from the glass surfaces

    DEFF Research Database (Denmark)

    Schultz, Jørgen Munthe

    1998-01-01

    A sealed glazing unit with 3 horisontal and 3 vertical bars and a reference glazing without bars have been tested in a guarded hotbox. The difference in measured heat loss coefficient between the two test objects is a measure of the thermal influence of the bars. The difference in heat loss...

  6. Triple bar, high efficiency mechanical sealer

    Science.gov (United States)

    Pak, Donald J.; Hawkins, Samantha A.; Young, John E.

    2013-03-19

    A clamp with a bottom clamp bar that has a planar upper surface is provided. The clamp may also include a top clamp bar connected to the bottom clamp bar, and a pressure distribution bar between the top clamp bar and the bottom clamp bar. The pressure distribution bar may have a planar lower surface in facing relation to the upper surface of the bottom clamp bar. An object is capable of being disposed in a clamping region between the upper surface and the lower surface. The width of the planar lower surface may be less than the width of the upper surface within the clamping region. Also, the pressure distribution bar may be capable of being urged away from the top clamp bar and towards the bottom clamp bar.

  7. Observations of barred spirals

    International Nuclear Information System (INIS)

    Elmegreen, D.M.

    1990-01-01

    Observations of barred spiral galaxies are discussed which show that the presence of a bar increases the likelihood for grand design spiral structure only in early Hubble types. This result is contrary to the more common notion that grand design spiral structure generally accompanies bars in galaxies. Enhanced deprojected color images are shown which reveal that a secondary set of spiral arms commonly occurs in barred galaxies and also occasionally in ovally distorted galaxies. 6 refs

  8. vertical bar Vub vertical bar from exclusive semileptonic B→π decays

    International Nuclear Information System (INIS)

    Flynn, Jonathan M.; Nieves, Juan

    2007-01-01

    We use Omnes representations of the form factors f + and f 0 for exclusive semileptonic B→π decays, paying special attention to the treatment of the B* pole and its effect on f + . We apply them to combine experimental partial branching fraction information with theoretical calculations of both form factors to extract vertical bar V ub vertical bar. The precision we achieve is competitive with the inclusive determination and we do not find a significant discrepancy between our result, vertical bar V ub vertical bar=(3.90+/-0.32+/-0.18)x10 -3 , and the inclusive world average value (4.45+/-0.20+/-0.26)x10 -3 [Heavy Flavor Averaging Group (HFAG), hep-ex/0603003

  9. Determining vertical bar Vub vertical bar from the B-bar→Xulν-bar dilepton invariant mass spectrum

    International Nuclear Information System (INIS)

    Bauer, Christian W.; Ligeti, Zoltan; Luke, Michael

    2001-01-01

    The invariant mass spectrum of the lepton pair in inclusive semileptonic B-bar→X u lν-bar decay yields a model independent determination of vertical bar V ub vertical bar. Unlike the lepton energy and hadronic invariant mass spectra, nonperturbative effects are only important in the resonance region, and play a parametrically suppressed role when dΓ/dq 2 is integrated over q 2 >(m B -m D ) 2 , which is required to eliminate the B-bar→X c lν-bar background. We discuss these backgrounds for q 2 slightly below (m B -m D ) 2 , and point out that instead of q 2 >(m B -m D ) 2 =11.6 GeV 2 , the cut can be lowered to q 2 > or approx. 10.5 GeV 2 . This is important experimentally, particularly when effects of a finite neutrino reconstruction resolution are included

  10. Experimental investigation on the threshold chloride concentration for corrosion initiation in reinforced concrete structures

    International Nuclear Information System (INIS)

    Byung Hwan Oh; Seung Yup Jang

    2005-01-01

    The corrosion of steel reinforcements in concrete is of great importance in the view of safety and durability of reinforced concrete structures. This study is focused on the corrosion behavior of steel bars induced by internal chlorides in concrete. The main objective of this study is to determine the threshold chloride concentration causing depassivation and active corrosion of steel reinforcement in concrete. To examine the threshold concentration of chloride ion, the half-cell potential, the chemical composition of extracted pore solutions of concrete and the extent of corroded area of the specimens were measured. Major test variables include the added amount of chlorides in concrete, type of binder, and water-to-binder ratios. From the present comprehensive test results, the factors influencing threshold chloride concentration are investigated, and the rational ranges of threshold chloride concentration causing active corrosion of steels are proposed. The present study provides the realistic chloride limit for corrosion initiation of reinforced concrete structures, which can be used efficiently in the future technical specification. (authors)

  11. Ultrasound-Guided Bar Edge Labeling in the Perioperative Assessment of Nuss Bar Removal.

    Science.gov (United States)

    Incerti, Filippo; Bertocchini, Alessia; Ghionzoli, Marco; Messineo, Antonio

    2017-12-01

    Nuss bar removal after minimally invasive repair of pectus excavatum in patients where bar ends are not palpable, can be a challenging procedure for the surgeon; a blind dissection toward the bar edges may lead to intercostal vessels or deep intercostal muscle injuries. In this article, we describe a fast, repeatable, low-cost technique to detect bar edge and stabilizers. A perioperative scan is performed by means of a portable ultrasonograph a few minutes before the operation. The bar edge stabilizer is detected as a hyperechogenic image with a concentric crescent while the bar edge is detected as a hyperechogenic dashed line with net edges. The scan is performed, and the actual projection on the skin of the metal plaque bulk is then labeled on the patient's chest by an ink marker. We believe that this method may improve morbidity, operative time, and consequently, hospitalization length and costs.

  12. Composite Behavior of Insulated Concrete Sandwich Wall Panels Subjected to Wind Pressure and Suction

    Directory of Open Access Journals (Sweden)

    Insub Choi

    2015-03-01

    Full Text Available A full-scale experimental test was conducted to analyze the composite behavior of insulated concrete sandwich wall panels (ICSWPs subjected to wind pressure and suction. The experimental program was composed of three groups of ICSWP specimens, each with a different type of insulation and number of glass-fiber-reinforced polymer (GFRP shear grids. The degree of composite action of each specimen was analyzed according to the load direction, type of the insulation, and number of GFRP shear grids by comparing the theoretical and experimental values. The failure modes of the ICSWPs were compared to investigate the effect of bonds according to the load direction and type of insulation. Bonds based on insulation absorptiveness were effective to result in the composite behavior of ICSWP under positive loading tests only, while bonds based on insulation surface roughness were effective under both positive and negative loading tests. Therefore, the composite behavior based on surface roughness can be applied to the calculation of the design strength of ICSWPs with continuous GFRP shear connectors.

  13. Measurement of $\\sigma_{t\\bar{t}b\\bar{b}}/\\sigma_{t\\bar{t}jj}$ ratio at 13 TeV with the CMS Detector

    CERN Document Server

    Jo, Young-kwon

    2016-01-01

    The measurement of the cross section ratio $\\sigma_{t\\bar{t}b\\bar{b}}/\\sigma_{t\\bar{t}jj}$ is presented using a data sample corresponding to an integrated luminosity of 2.3~$\\rm{fb}^{-1}$ collected in pp collisions at \\\\ $\\sqrt{s}$ = 13TeV with the CMS detector at the LHC. Events with two leptons and at least four reconstructed jets, including at least two identified as b quark jets, in the final state are selected. The measured ratio is $0.022 \\pm 0.003$(stat.)$\\pm0.006$(syst.) in the full phase space. The measured cross section $\\sigma_{t\\bar{t}b\\bar{b}}$ is $3.9 \\pm 0.6$(stat.)$\\pm1.3$(syst.) pb and $\\sigma_{t\\bar{t}jj}$ is $176 \\pm 5$(stat.)$ \\pm 33 $(syst.) pb.

  14. Axisymmetric analysis of a 1:6-scale reinforced concrete containment building using a distributed cracking model for the concrete

    International Nuclear Information System (INIS)

    Weatherby, J.R.

    1987-09-01

    Results of axisymmetric structural analyses of a 1:6 scale model of a reinforced concrete nuclear containment building are presented. Both a finite element shell analysis and a simplified membrane analysis were made to predict the structural response and ultimate pressure capacity of the model. Analytical results indicate that the model will fail at an internal pressure of 187 psig when the stress level in the hoop reinforcement at the midsection of the cylinder exceeds the ultimate strength of the bar splices. 5 refs., 34 figs., 6 tabs

  15. Strength and durability of near-surface mounted CFRP bars for shear strengthening reinforced concrete bridge girders.

    Science.gov (United States)

    2012-03-01

    During the interstate expansion of the 1950s, many conventionally reinforced concrete deck girder bridges were built throughout the country. These aging bridges commonly exhibit diagonal cracking and rate inadequately for shear, thus they are candida...

  16. Thermal test of the insulation structure for LH 2 tank by using the large experimental apparatus

    Science.gov (United States)

    Kamiya, S.; Onishi, K.; Konshima, N.; Nishigaki, K.

    Conceptual designs of large mass LH 2 (liquid hydrogen) storage systems, whose capacity is 50,000 m3, have been studied in the Japanese hydrogen project, World Energy Network (WE-NET) [K. Fukuda, in: WE-NET Hydrogen Energy Symposium, 1999, P1-P41]. This study has concluded that their thermal insulation structures for the huge LH 2 tanks should be developed. Their actual insulation structures comprise not only the insulation material but also reinforced members and joints. To evaluate their thermal performance correctly, a large test specimen including reinforced members and joints will be necessary. After verifying the thermal performance of a developed large experimental apparatus [S. Kamiya, Cryogenics 40 (1) (2000) 35] for measuring the thermal conductance of various insulation structures, we tested two specimens, a vacuum multilayer insulation (MLI) with a glass fiber reinforced plastic (GFRP) support and a vacuum solid insulation (microtherm ®) with joints. The thermal background test for verifying the thermal design of the experimental apparatus showed that the background heat leak is 0.1 W, small enough to satisfy apparatus performance requirement. The thermal conductance measurements of specimens also showed that thermal heat fluxes of MLI with a GFRP support and microtherm ® are 8 and 5.4 W/m2, respectively.

  17. The cc-bar and bb-bar spectroscopy in the two-step potential model

    International Nuclear Information System (INIS)

    Kulshreshtha, D.S.; Kaiserslautern Univ.

    1984-07-01

    We investigate the spectroscopy of the charmonium (cc-bar) and bottonium (bb-bar) bound states in a static flavour independent nonrelativistic quark-antiquark (qq-bar) two-step potential model proposed earlier. Our predictions are in good agreement with experimental data and with other theoretical predictions. (author)

  18. Strength and deformational characteristics of three-way reinforced concrete containment models subjected to lateral forces

    International Nuclear Information System (INIS)

    Aoyagi, Y.; Yamada, K.; Takahashi, T.

    1981-01-01

    With a view to investigating the earthquake resistance characteristics of reinforced concrete containments two cylindrical models with three-way system of bars were made and loaded laterally up to failure combined with or without internal pressures, simulating the conditions in which containments were subjected to earthquake forces at a simultaneous LOCA or at normal operation. The main conclusions obtained withing the limit of the experiments are as follows. (1) Stresses in reinforcements in three-way reinforced concrete plate elements can reasonably be estimated by the equations proposed by Baumann. It is, however, necessary to take into consideration the contributions of concrete between cracks to the deformation in order to accurately estimate the average strains in the plate elements, applying such a formula as CEB as reformed by the authors. (2) The strength capacity of three-way reinforced concrete containments against lateral forces combined with internal pressure is somewhat inferior to that of orthogonally reinforced one if compared on the condition that the volumetric reinforcement ratios are the same for the two cases of reinforcement arrangements. However, three-way reinforcement improves initial shear rigidity as well as ultimate horizontal deformability for lateral forces. (3) The ability for three-way reinforced concrete containment to absorb strain energy in the range of large deformations is superior to that of orthogonally reinforced one. The equivalent viscous damping coefficient for the former is markedly larger than that for the latter, especially at the increased deformational stages. These experimental evidences suggent that three-way system of reinforcement may constitute one of the prospective measures to improve the earthquake resistance of reinforced concrete containments. (orig./HP)

  19. Identification of corrosion in reinforcement rebars by using the GPR

    Directory of Open Access Journals (Sweden)

    Mechbal Z.

    2014-01-01

    Full Text Available Considering the problem of corroded steel reinforcements buried in concrete members, a methodology based on ground penetrating radar was proposed for the identification of the corrosion affected zone. The method uses post-processing of radargram as obtained from a classic B-scan realized by the electromagnetic radar, when working with adequate high frequencies that are usually used for inspection of reinforced concrete structures. The radar displays are in general complex and not easy to interpret. However, significant information can be extracted from the obtained images to make a reliable report after the inspection. In this context, a correlation formula was proposed previously to estimate the perimeter of a reinforcement bar which is embedded in a concrete massif by using the radargram traces. This formula was employed in the present work in order to estimate the corroded zone perimeter. The obtained results have shown that it provides good prediction of the deterioration extent. Clear contrast of traces was noticed also while modifying the depth of the corrosion affected zone. However, to obtain the depth of the corroded segment of the rebar, further developments concerning image processing of a radargram are required.

  20. Improving the Wear Resistance of Moulds for the Injection of Glass Fibre–Reinforced Plastics Using PVD Coatings: A Comparative Study

    Directory of Open Access Journals (Sweden)

    Francisco Silva

    2017-02-01

    Full Text Available It is well known that injection of glass fibre–reinforced plastics (GFRP causes abrasive wear in moulds’ cavities and runners. Physical vapour deposition (PVD coatings are intensively used to improve the wear resistance of different tools, also being one of the most promising ways to increase the moulds’ lifespan, mainly when used with plastics strongly reinforced with glass fibres. This work compares four different thin, hard coatings obtained using the PVD magnetron sputtering process: TiAlN, TiAlSiN, CrN/TiAlCrSiN and CrN/CrCN/DLC. The first two are monolayer coatings while the last ones are nanostructured and consist of multilayer systems. In order to carry out the corresponding tribological characterization, two different approaches were selected: A laboratorial method, using micro-abrasion wear tests based on a ball-cratering configuration, and an industrial mode, analysing the wear resistance of the coated samples when inserted in a plastic injection mould. As expected, the wear phenomena are not equivalent and the results between micro-abrasion and industrial tests are not similar due to the different means used to promote the abrasion. The best wear resistance performance in the laboratorial wear tests was attained by the TiAlN monolayer coating while the best performance in the industrial wear tests was obtained by the CrN/TiAlCrSiN nanostructured multilayer coating.

  1. Numerical Investigation on Stress Concentration of Tension Steel Bars with One or Two Corrosion Pits

    Directory of Open Access Journals (Sweden)

    Jian Hou

    2015-01-01

    Full Text Available Pitting corrosion has been observed in steel bars of existing reinforced concrete (RC structures in different erosion environments and has been identified as a potential origin for fatigue crack nucleation. In the present study, under uniaxial tension loading, stress distribution in the steel bars with one or two semiellipsoidal corrosion pits has systematically been investigated by conducting a series of three-dimensional semiellipsoidal pitted models. Based on the finite element analyses, it is shown that stress concentration factor (SCF increases linearly with increasing pit aspect ratio (a/b and increases nonlinearly with increasing pit relative depth (a/R for single corrosion pit problem. For double corrosion pits problem, the SCF decreases nonlinearly with increasing angle of two transverse pits (θ. The interaction of two longitudinal pits can be ignored in the calculation of SCF even if the distance of two pits (d is very small.

  2. Development of an effective pinch bar

    CSIR Research Space (South Africa)

    Ottermann, RW

    2003-02-01

    Full Text Available . ....................................10 Figure 3-3: Layout of lightweight pinch bar extruded fibreglass tube. ..................................11 Figure 3-4: XDM lightweight pinch bar with manufactured glass fibre bar. ..........................12 Figure 3-5: XDM lightweight pinch... bar with extruded glass fibre tube. ................................12 Figure 3-6: Stiffness of a 2.8m lightweight pinch bar with an extruded glass fibre tube and a 25mm steel pinch bar...

  3. $\\chi^{\\vphantom\\dagger}_{c0}(3915)$ As the Lightest $c\\bar c s \\bar s$ State

    CERN Document Server

    Lebed, Richard F.

    2016-05-23

    The state $\\chi^{\\vphantom\\dagger}_{c0}(3915)$ has recently been demoted by the Particle Data Group from its previous status as the conventional $c\\bar c$ $2 {}^3P_0$ state, largely due to the absence of expected $D\\bar D$ decays. We propose that $\\chi^{\\vphantom\\dagger}_{c0}(3915)$ is actually the lightest $c\\bar c s \\bar s$ state, and calculate the spectrum of such states using the diquark model, identifying many of the observed charmoniumlike states that lack open-charm decay modes as $c\\bar c s \\bar s$. Among other results, we argue that $Y(4140)$ is a $J^{PC} = 1^{++}$ $c\\bar c s \\bar s$ state that has been not been seen in two-photon fusion largely as a consequence of the Landau-Yang theorem.

  4. Study of the ρ-bar, β-bar and Λ parameters of a light-water reactor

    International Nuclear Information System (INIS)

    Riche, R.

    1965-09-01

    The kinetic and perturbation equations are derived from the time-dependent transport equation. Kinetic equations depend only on the ratios a = ρ-bar/β-bar and b = β-bar/Λ, which are definite, while the reactivity ρ-bar, the delayed neutron fraction (β-bar and the generation time Λ are expressed in terms of an arbitrary function I. The 'static' definitions of these parameters, which reduce kinetic problems to a set of purely term dependent equations, introduce the effective fraction β-bar. One way of determining experimentally the ratio b is presented; it consists in analysing the power transient after a rapid variation of the reactivity, caused by the implosion of an empty glass-bull. A simple interpretation is proposed. The apparatus can be transformed easily into a reactimeter. The value of the effective delayed neutron fraction β-bar has been determined by averaging the reactivity effects of a copper sheet through out the reactor core. Experimental results: b = β-bar/Λ = 129 s -1 and β-bar 795.10 -5 , have been determined on a light-water moderated, enriched-uranium fuelled reactor. The calculated values of the effectiveness of delayed neutrons γ β-bar/β 1.23 and the generation time Λ 59.10 -6 s agrees fairly well with the experimental results. (author) [fr

  5. Experimental Investigation on Strengthening of Bolted Connections in Transmission/Communication Towers

    Science.gov (United States)

    Balagopal, R.; Prasad Rao, N.; Rokade, R. P.; Umesha, P. K.

    2018-02-01

    Due to increase in demand for power supply and increase in bandwidth for communication industry, the existing transmission line (TL) and communication towers needs to be strengthened. The strengthening of existing tower is economical rather than installation of new towers due to constraints in acquisition of land. The size of conductors have to be increased or additional number of antenna needs to be installed in existing TL/communication tower respectively. The compression and tension capacity of members in the existing towers have to be increased to sustain the additional loads due to wind and self-weight of these components. The tension capacity enhancement of existing angle sections in live line condition without power shut-down is a challenging task. In the present study, the use of Glass Fiber Reinforced Plastic (GFRP) plate/angle sections is explored to strengthen existing bolted connections in TL/communication towers. Experimental investigation conducted at component level on strengthening of existing two types of single cover steel butt joint, one made of steel plate and another joint made of steel angle sections respectively. First series of experiment conducted on strengthening the connection using GFRP plate/cleat angle sections. The second series of strengthening experiment is conducted using steel plate/angle sections to replace GFRP sections. The load sharing behaviour of strengthened GFRP and steel section is compared and suitable recommendations are given.

  6. Experimental Investigation on Strengthening of Bolted Connections in Transmission/Communication Towers

    Science.gov (United States)

    Balagopal, R.; Prasad Rao, N.; Rokade, R. P.; Umesha, P. K.

    2018-06-01

    Due to increase in demand for power supply and increase in bandwidth for communication industry, the existing transmission line (TL) and communication towers needs to be strengthened. The strengthening of existing tower is economical rather than installation of new towers due to constraints in acquisition of land. The size of conductors have to be increased or additional number of antenna needs to be installed in existing TL/communication tower respectively. The compression and tension capacity of members in the existing towers have to be increased to sustain the additional loads due to wind and self-weight of these components. The tension capacity enhancement of existing angle sections in live line condition without power shut-down is a challenging task. In the present study, the use of Glass Fiber Reinforced Plastic (GFRP) plate/angle sections is explored to strengthen existing bolted connections in TL/communication towers. Experimental investigation conducted at component level on strengthening of existing two types of single cover steel butt joint, one made of steel plate and another joint made of steel angle sections respectively. First series of experiment conducted on strengthening the connection using GFRP plate/cleat angle sections. The second series of strengthening experiment is conducted using steel plate/angle sections to replace GFRP sections. The load sharing behaviour of strengthened GFRP and steel section is compared and suitable recommendations are given.

  7. Measurement of vertical bar Vub vertical bar in semi-inclusive charmless B → πX decays

    International Nuclear Information System (INIS)

    Kim, C.S.; Lee, Jake; Oha, Sechul

    2002-01-01

    We study semi-inclusive charmless decays B → πX, where X does not contain a charm (anti)quark. The mode B-bar 0 → π - X turns out to be be particularly useful for determination of the CKM matrix element vertical bar V ub vertical bar. We present the branching ratio (BR) of B-bar 0 → π - X as a function of vertical bar V ub vertical bar, with an estimation of possible uncertainty. The BR is expected to be an order of 10 -4

  8. Bank pull or bar push: What drives scroll-bar formation in meandering rivers?

    NARCIS (Netherlands)

    van de Lageweg, W. I.; van Dijk, W. M.; Baar, A. W.; Rutten, J.; Kleinhans, M. G.

    2014-01-01

    One of the most striking features of meandering rivers are quasi-regular ridges of the point bar, evidence of a pulsed lateral migration of meander bends. Scroll bars formed on the inner bend are preserved on the point-bar surface as a series of ridges as meanders migrate, and in the subsurface of

  9. Effects of Reinforcement on Denture Strain in Maxillary Implant Overdentures: An In Vitro Study Under Various Implant Configurations.

    Science.gov (United States)

    Takahashi, Toshihito; Gonda, Tomoya; Maeda, Yoshinobu

    Maxillary implant overdentures are often designed without palatal coverage to maximize wearer comfort. Although palateless dentures have been reported to be less rigid than conventional dentures, and require reinforcement to prevent complications, there is little documentation about the effects of such reinforcement. The purpose of this study was to examine the effects of reinforcement on the strain on maxillary implant overdentures supported by implants in a variety of configurations. A maxillary edentulous model with implants inserted in the anterior, premolar, and molar area was fabricated. Five types of experimental overdentures, with and without reinforcement, were fabricated, and two strain gauges were attached at the anterior midline of the labial and palatal sides. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the shear strain on the denture was measured. The measurements were compared using the Kruskal-Wallis test (P = .05). On both the labial and palatal sides, the strain on the palateless dentures with reinforcement was significantly lower than the strain on palateless dentures without reinforcement in all implant configurations (P overdenture with residual ridge reinforcement and a palatal bar could reduce the strain in the anterior midline to almost the same level as a denture with palatal coverage. This type of reinforcement may prevent prosthetic and implant complications.

  10. Determination of the quark coupling strength vertical bar V-ub vertical bar using baryonic decays

    NARCIS (Netherlands)

    Aaij, R.; Adeva, B.; Adinolfi, M.; Older, A. A.; Ajaltouni, Z.; Akar, S.; Albrecht, J.; Alessio, F.; Alexander, M.; Ali, S.; Alkhazov, G.; Cartelle, P. Alvarez; Alves, A. A.; Amato, S.; Amerio, S.; Amhis, Y.; An, L.; Anderlini, L.; Andreotti, M.; Andrews, J. E.; Appleby, R. B.; Gutierrez, O. Aquines; Archilli, F.; Artamonov, A.; Artuso, M.; Aslanides, E.; Auriemma, G.; Baalouch, M.; Bachmann, S.; Back, J. J.; Badalov, A.; Baesso, C.; Baldini, W.; Barlow, R. J.; Barschel, C.; Barsuk, S.; Barter, W.; Batozskaya, V.; Battista, V.; Beaucourt, L.; Beddow, J.; Bedeschi, F.; Bediaga, I.; Bel, L. J.; Belyaev, I.; Ben-Haim, E.; Bencivenni, G.; Onderwater, C. J. G.; Pellegrino, A.; Tolk, S.

    In the Standard Model of particle physics, the strength of the couplings of the b quark to the u and c quarks, vertical bar V-ub vertical bar and vertical bar V-ub vertical bar, are governed by the coupling of the quarks to the Higgs boson. Using data from the LHCb experiment at the Large Hadron

  11. What makes the family of barred disc galaxies so rich: damping stellar bars in spinning haloes

    Science.gov (United States)

    Collier, Angela; Shlosman, Isaac; Heller, Clayton

    2018-05-01

    We model and analyse the secular evolution of stellar bars in spinning dark matter (DM) haloes with the cosmological spin λ ˜ 0-0.09. Using high-resolution stellar and DM numerical simulations, we focus on angular momentum exchange between stellar discs and DM haloes of various axisymmetric shapes - spherical, oblate, and prolate. We find that stellar bars experience a diverse evolution that is guided by the ability of parent haloes to absorb angular momentum, J, lost by the disc through the action of gravitational torques, resonant and non-resonant. We confirm that dynamical bar instability is accelerated via resonant J-transfer to the halo. Our main findings relate to the long-term secular evolution of disc-halo systems: with an increasing λ, bars experience less growth and basically dissolve after they pass through vertical buckling instability. Specifically, with increasing λ, (1) the vertical buckling instability in stellar bars colludes with inability of the inner halo to absorb J - this emerges as the main factor weakening or destroying bars in spinning haloes; (2) bars lose progressively less J, and their pattern speeds level off; (3) bars are smaller, and for λ ≳ 0.06 cease their growth completely following buckling; (4) bars in λ > 0.03 haloes have ratio of corotation-to-bar radii, RCR/Rb > 2, and represent so-called slow bars without offset dust lanes. We provide a quantitative analysis of J-transfer in disc-halo systems, and explain the reasons for absence of growth in fast spinning haloes and its observational corollaries. We conclude that stellar bar evolution is substantially more complex than anticipated, and bars are not as resilient as has been considered so far.

  12. Implementation of viscoelastic Hopkinson bars

    Directory of Open Access Journals (Sweden)

    Govender R.

    2012-08-01

    Full Text Available Knowledge of the properties of soft, viscoelastic materials at high strain rates are important in furthering our understanding of their role during blast or impact events. Testing these low impedance materials using a metallic split Hopkinson pressure bar setup results in poor signal to noise ratios due to impedance mismatching. These difficulties are overcome by using polymeric Hopkinson bars. Conventional Hopkinson bar analysis cannot be used on the polymeric bars due to the viscoelastic nature of the bar material. Implementing polymeric Hopkinson bars requires characterization of the viscoelastic properties of the material used. In this paper, 30 mm diameter Polymethyl Methacrylate bars are used as Hopkinson pressure bars. This testing technique is applied to polymeric foam called Divinycell H80 and H200. Although there is a large body of of literature containing compressive data, this rarely deals with strain rates above 250s−1 which becomes increasingly important when looking at the design of composite structures where energy absorption during impact events is high on the list of priorities. Testing of polymeric foams at high strain rates allows for the development of better constitutive models.

  13. Flexural behaviour and punching shear of selfcompacting concrete ribbed slab reinforced with steel fibres

    Directory of Open Access Journals (Sweden)

    Ahmad Hazrina

    2017-01-01

    Full Text Available This paper investigates the effects of steel fibres as a replacement to the conventional reinforcement under flexural behaviour and punching shear in self-compacting (SCC ribbed slab reinforced with steel fibres. Four ribbed slabs with similar dimensions of 2.8 m length × 1.2 m width and 0.2m thickness were constructed. Two of the samples were considered as control samples (conventionally reinforced with reinforcement bars and welded mesh while another two samples were fully reinforced with 1% (80 kg/m3 volume of steel fibres incorporated to the SCC mix. For the flexural behaviour study, the ribbed slab samples were subjected to two line loads under four point bending. Meanwhile, for the punching shear analysis, the ribbed slab samples were subjected to a point load to simulate loading from the column. The analysis of the experimental results displayed that steel fibres incorporation had been found to effectively delay the first crack occurrence under both flexural and punching shear. The steel fibre replacement has been proven to be able to sustain up to 80% and 73% of the ultimate load resistance for flexural and punching shear, respectively, in comparison to conventionally reinforced ribbed slab structure. The visual observation carried out during the experiment exhibited similar failure mode for both steel fibre reinforced and control samples. This was observed for both flexural and punching shear samples. Overall, it can be concluded that the steel fibres had displayed a promising potential to effectively replace the conventional reinforcements.

  14. The characteristics of acoustic emission signal under composite destruction on GFRP gas cylinder

    International Nuclear Information System (INIS)

    Jee, Hyun Sup; Lee, Jong O; Ju, No Hoe; So, Cheal Ho; Lee, Jong Kyu

    2013-01-01

    This study is investigation of the characteristics for acoustic emission signal generated by destruction on glass fiber bundles and specimen that was machined composite materials surrounding the outside of GFRP cylinder. The Amplitude of acoustic emission signal gets bigger as the cutting angle of knife increases. Accordingly, the number of hits in destruction of composite materials specimen have more in longitudinal direction (longitudinal direction to the glass fiber) than in hoop direction (horizontal direction to the glass fiber) while the amplitude of signals were bigger in hoop direction than longitudinal direction. It was found out that the amplitude of the glass fiber breakage is more than 40 dB and that the amplitude of signal for matrix crack was less than 40 dB because matrix crack signal was not observed when threshold value is 40 dB and matrix crack signal suddenly appeared when threshold value is 32 dB. The slope of the amplitude is related to the acoustic emission source and the slope of the amplitude of the horizontal and vertical directions are 0.16 and 0.08. In particular, The slope of the amplitude of longitudinal direction breakage appear similar to the glass fiber breakage and therefore Acoustic emission source of longitudinal direction breakage is estimated the glass fiber breakage.

  15. Ultrasonic assessment of service life of concrete structures subject to reinforcing steel corrosion

    Science.gov (United States)

    Udegbunam, Ogechukwu Christian

    Over half of the bridges in the United States were built before 1970. Such bridges and the network of roads that they carry include the Inter State system, which was built as part of the great public works program, following the end of the Second World War. During that era, the emphasis was on strength design and economical construction of new structures, and not much premium was placed on durability and maintainability concerns. Since the end of this construction boom in the early 1970s, the concern for the durability of transportation infrastructure has steadily gained prominence among those agencies that must secure, program and administer funds for maintaining highway networks. The objective of this research was to develop a nondestructive method of assessing the durability of concrete bridge decks susceptible to damage from corrosion of embedded reinforcing steel. This was accomplished by formulating a holistic approach that accounts for the major factors that influence corrosion based deterioration of reinforced concrete. In this approach, the assessment of the durability of concrete bridge decks is based on a model that estimates the time it takes for the cover concrete to fail a result of stresses caused by expansion of reinforcing steel bars, due to corrosion activities. This time to failure is comprised of two distinct periods that must be evaluated before the problem can be solved. The research consisted of an experimental program and an analytical study. In the experimental program concrete specimens were cast and tested to determine their diffusivity and mechanical properties. The diffusivity was used to evaluate the period it takes for corrosion of the reinforcing bars to commence. In the analytical study, the resistance of the concrete structure against the internal forces caused by corrosion was evaluated with the finite element techniques. This resistance was used to evaluate the period defining the failure of the cover concrete. These two periods

  16. Bar codes for nuclear safeguards

    International Nuclear Information System (INIS)

    Keswani, A.N.; Bieber, A.M. Jr.

    1983-01-01

    Bar codes similar to those used in supermarkets can be used to reduce the effort and cost of collecting nuclear materials accountability data. A wide range of equipment is now commercially available for printing and reading bar-coded information. Several examples of each of the major types of commercially available equipment are given, and considerations are discussed both for planning systems using bar codes and for choosing suitable bar code equipment

  17. Bar codes for nuclear safeguards

    International Nuclear Information System (INIS)

    Keswani, A.N.; Bieber, A.M.

    1983-01-01

    Bar codes similar to those used in supermarkets can be used to reduce the effort and cost of collecting nuclear materials accountability data. A wide range of equipment is now commercially available for printing and reading bar-coded information. Several examples of each of the major types of commercially-available equipment are given, and considerations are discussed both for planning systems using bar codes and for choosing suitable bar code equipment

  18. Search for the decay of a B0 or B0bar meson to K*0bar K0 or K*0 K0bar

    Energy Technology Data Exchange (ETDEWEB)

    Aubert, B.

    2006-06-27

    The authors present a search for the decay of a B{sup 0} or {bar B}{sup 0} meson to a {bar K}*{sup 0} K{sup 0} or K*{sup 0} {bar K}{sup 0} final state, using a sample of approximately 232 million B{bar B} events collected with the BABAR detector at the PEP-II asymmetric energy e{sup +}e{sup -} collider at SLAC. The measured branching fraction is {Beta}(B{sup 0} {yields} {bar K}*{sup 0} K{sup 0}) + {Beta}(B{sup 0} {yields} K*{sup 0} {bar K}{sup 0}) = (0.2{sub -0.8, -0.3}{sup +0.9, +0.1}) x 10{sup -6}. They obtain the following upper limit for the branching fraction at 90% confidence level: {Beta}(B{sup 0} {yields} {bar K}*{sup 0} K{sup 0}) + {Beta}(B{sup 0} {yields} K*{sup 0} {bar K}{sup 0}) < 1.9 x 10{sup -6}. They use our result to constrain the Standard Model prediction for the deviation of the CP asymmetry in B{sup 0} {yields} {phi}K{sup 0} from sin 2{beta}.

  19. Effect of the Type of Surface Treatment and Cement on the Chloride Induced Corrosion of Galvanized Reinforcements

    Science.gov (United States)

    Tittarelli, Francesca; Mobili, Alessandra; Vicerè, Anna Maria; Roventi, Gabriella; Bellezze, Tiziano

    2017-10-01

    The effect of a new passivation treatment, obtained by immersion of the galvanized reinforcements in a trivalent chromium salts based solution, on the chlorides induced corrosion has been investigated. To investigate also the effect of cement alkalinity on corrosion behaviour of reinforcements, concretes manufactured with three different European cements were compared. The obtained results show that the alternative treatment based on hexavalent chromium-free baths forms effective protection layers on the galvanized rebar surfaces. The higher corrosion rates of zinc coating in concrete manufactured with Portland cement compared to those recorded for bars in concrete manufactured with pozzolanic cement depends strongly on the higher chloride content at the steel concrete interface.

  20. Data of the properties of rebar steel brands in Lagos, Nigerian market used in reinforced concrete applications.

    Science.gov (United States)

    Joshua, Opeyemi; Olusola, Kolapo O; Oyeyemi, Kehinde D; Ogunde, Ayodeji O; Amusan, Lekan M; Nduka, David O; Abuka-Joshua, Joyce

    2018-04-01

    The data presented herein are compilations of the research summary of "Assessment of the Quality of Steel Reinforcement Bars Available in Nigerian Market" (Joshua et al., 2013) [1]. This data article provides information on the properties and cost of steel rebars used in reinforced concrete in Lagos, Nigeria. The data is based on the properties of 12 mm rebar brands which are the most used steel diameter in construction and they include actual diameters, yield strengths, ultimate strengths, ultimate/yield strength ratio, ductility and the cost of each brand. This data also contains the limiting standard properties of the highlighted properties in this data.

  1. Post-cracking behavior of blocks, prisms, and small concrete walls reinforced with plant fiber

    OpenAIRE

    Soto, I. I.; Ramalho, M. A.; Izquierdo, O. S.

    2013-01-01

    Structural masonry using concrete blocks promotes the rationalization of construction projects, lowering the final cost of a building through the elimination of forms and the reduction of the consumption of reinforcement bars. Moreover, production of a block containing a combination of concrete and vegetable fiber sisal results in a unit with properties such as mechanical strength, stiffness, flexibility, ability to absorb energy, and post-cracking behavior that are comparable to those of a b...

  2. Strength of precast concrete shear joints reinforced with high-strength wire ropes

    DEFF Research Database (Denmark)

    Joergensen, Henrik B.; Hoang, Linh Cao; Hagsten, Lars German

    2017-01-01

    This paper concerns the in-plane shear strength of connections between precast concrete wall elements reinforced with looped high-strength wire ropes. The looped wire ropes are pre-installed in so-called ‘wire boxes’ which function as shear keys. Although only a small amount of research...... on the shear strength of such connections can be found in the literature, this type of connection is increasingly being used because wire ropes are much more construction-friendly than traditional U-bars. A rigid plastic upper bound model for the shear strength of wall connections reinforced with looped wire...... ropes that are pre-installed in wire boxes is presented along with test results on the shear strength of connections with double-wire boxes. It is shown that the plastic solution agrees well with both the obtained test results and results from previously conducted tests....

  3. Hyperon polarisation in the reaction p-bar sup 1 sup 2 C -> LAMBDA-bar LAMBDA X

    CERN Document Server

    Pomp, S; Bröders, R; Bunker, B; Dennert, H; Eisenstein, R E; Eyrich, W; Fischer, H; Franklin, G; Franz, J; Geyer, R; Harris, P; Hauffe, J; Hertzog, D; Johansson, T; Jones, T; Kilian, K; Kraft, R A; Meyer, C; Oelert, W; Quinn, B; Röhrich, K; Rössle, E; Sachs, K; Schmitt, H; Schumacher, R; Sefzick, T; Stinzing, F; Tayloe, R; Todenhagen, R; Traneus, E; Wirth, S

    2000-01-01

    Data from the p-bar sup 1 sup 2 C -> LAMBDA-bar LAMBDA X reaction, collected by the PS185 experiment at antiproton momenta around 1.44 GeV/c, 1.66 GeV/c and 1.77 GeV/c, have been analyzed and the LAMBDA and LAMBDA-bar polarisations have been extracted. The events are classified as quasi-free or non-quasi-free and it is found that the polarisations for LAMBDA and LAMBDA-bar differ in the latter case. Such an effect comes from differences in the interaction of the outgoing LAMBDA and LAMBDA-bar with the residual nucleus and the measurement constitutes the first information on LAMBDA-bar interaction with nuclear matter.

  4. Evaluation of Different Techniques of Active Thermography for Quantification of Artificial Defects in Fiber-Reinforced Composites Using Thermal and Phase Contrast Data Analysis

    Science.gov (United States)

    Maierhofer, Christiane; Röllig, Mathias; Gower, Michael; Lodeiro, Maria; Baker, Graham; Monte, Christian; Adibekyan, Albert; Gutschwager, Berndt; Knazowicka, Lenka; Blahut, Ales

    2018-05-01

    For assuring the safety and reliability of components and constructions in energy applications made of fiber-reinforced polymers (e.g., blades of wind turbines and tidal power plants, engine chassis, flexible oil and gas pipelines) innovative non-destructive testing methods are required. Within the European project VITCEA complementary methods (shearography, microwave, ultrasonics and thermography) have been further developed and validated. Together with partners from the industry, test specimens have been constructed and selected on-site containing different artificial and natural defect artefacts. As base materials, carbon and glass fibers in different orientations and layering embedded in different matrix materials (epoxy, polyamide) have been considered. In this contribution, the validation of flash and lock-in thermography to these testing problems is presented. Data analysis is based on thermal contrasts and phase evaluation techniques. Experimental data are compared to analytical and numerical models. Among others, the influence of two different types of artificial defects (flat bottom holes and delaminations) with varying diameters and depths and of two different materials (CFRP and GFRP) with unidirectional and quasi-isotropic fiber alignment is discussed.

  5. Failure behavior / characteristics of fabric reinforced polymer matrix composite and aluminum6061 on dynamic tensile loading

    Energy Technology Data Exchange (ETDEWEB)

    Bang, Hyejin; Cho, Chongdu [Inha University, Incheon (Korea, Republic of)

    2017-08-15

    Composite materials are composed of multiple types of materials as reinforcement and matrix. Among them, CFRP (Carbon fiber reinforced polymer) is widely used materials in automotive and defense industry. Carbon fibers are used as a reinforcement, of which Young's modulus is in a prepreg form. In automotive industry, especially, high strain rate test is needed to measure dynamic properties, used in dynamic analysis like high inertia included simulation as a car crash. In this paper, a SHTB (Split Hopkinson tensile bar) machine is employed for estimating stress-strain curve under dynamic load condition on aluminum 6061 and CFRP. The strain rate range is about from 100 /s to 1000 /s and the number of prepreg layers of composite specimen is total eight plies which are stacked symmetrically to structure CFRP. As a result, stress / strain point data are obtained and used for simulation into stacked composites.

  6. Failure behavior / characteristics of fabric reinforced polymer matrix composite and aluminum6061 on dynamic tensile loading

    International Nuclear Information System (INIS)

    Bang, Hyejin; Cho, Chongdu

    2017-01-01

    Composite materials are composed of multiple types of materials as reinforcement and matrix. Among them, CFRP (Carbon fiber reinforced polymer) is widely used materials in automotive and defense industry. Carbon fibers are used as a reinforcement, of which Young's modulus is in a prepreg form. In automotive industry, especially, high strain rate test is needed to measure dynamic properties, used in dynamic analysis like high inertia included simulation as a car crash. In this paper, a SHTB (Split Hopkinson tensile bar) machine is employed for estimating stress-strain curve under dynamic load condition on aluminum 6061 and CFRP. The strain rate range is about from 100 /s to 1000 /s and the number of prepreg layers of composite specimen is total eight plies which are stacked symmetrically to structure CFRP. As a result, stress / strain point data are obtained and used for simulation into stacked composites.

  7. Microstructure Characteristics of Fe-Matrix Composites Reinforced by In-Situ Carbide Particulates

    Science.gov (United States)

    Huang, Xiaodong; Song, Yanpei

    2017-10-01

    Carbide particulates reinforced iron-matrix composites were prepared by in-situ synthesis reaction between Ti, V and C on liquid alloys surface. The microstructure of the composite was characterized by SEM, TEM and OM. The results showed that the main phases were α-Fe, carbide particulate; besides, there were small amounts of γ-Fe and graphite (G) in the composite. The carbides were TiVC2 and VC in the shape of short bar and graininess. The matrix consisted of martensite and small amounts of retained austenite.

  8. Numerical simulations of wave propagation in long bars with application to Kolsky bar testing

    Energy Technology Data Exchange (ETDEWEB)

    Corona, Edmundo [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-11-01

    Material testing using the Kolsky bar, or split Hopkinson bar, technique has proven instrumental to conduct measurements of material behavior at strain rates in the order of 103 s-1. Test design and data reduction, however, remain empirical endeavors based on the experimentalist's experience. Issues such as wave propagation across discontinuities, the effect of the deformation of the bar surfaces in contact with the specimen, the effect of geometric features in tensile specimens (dog-bone shape), wave dispersion in the bars and other particulars are generally treated using simplified models. The work presented here was conducted in Q3 and Q4 of FY14. The objective was to demonstrate the feasibility of numerical simulations of Kolsky bar tests, which was done successfully.

  9. CP violation in hyperon decays: the case p-bar p → Λ-bar Λ → p-bar π+ pπ-

    International Nuclear Information System (INIS)

    Hamann, N.; He, X.G.; Landua, R.; Ohlsson, S.; Steger, H.; Valencia, G.; Fischer, H.; Geyer, R.; Hertzog, D.; Kolo, B.; Miller, J.P.; Rohrich, K.

    1992-01-01

    An account is given of the experimental status of CP violation and of the phenomenology of hyperon non-leptonic decays. Updated information on the estimate of CP-violating observable in these decays is presented. An experimental programme is outlined, which aims to pursue the search for direct CP violation in hyperon-antihyperon decays by means of the reaction p-bar p → Λ-bar Λ → p-bar π + pπ - . The experiment as well as analysis methods are described. Alternative approaches employing hyperons are also discussed. 54 refs., 1 tab., 13 figs

  10. [Interaction between neurons of the frontal cortex and hippocampus during the realization of choice of food reinforcement quality in cats].

    Science.gov (United States)

    Merzhanova, G Kh; Dolbakian, E E; Khokhlova, V N

    2003-01-01

    Six cats were subjected to the procedure of appetitive instrumental conditioning (with light as a conditioned stimuls) by the method of the "active choice" of reinforcement quality. Short-delay conditioned bar-press responses were rewarded with bread-meat mixture, and the delayed responses were reinforced by meat. The animals differed in behavior strategy: four animals preferred the bar-pressing with a long delay (the so-called "self-control" group), and two cats preferred the bar-pressing with a short delay (the so-called "impulsive" group). Multiunit activity in the frontal cortex and hippocampus (CA3) was recorded via chronically implanted nichrome wire semimicroelectrodes. An interaction between the neighboring neurons in the frontal cortex and hippocampus (within local neural networks) and between the neurons of the frontal cortex and hippocampus (distributed neural networks in frontal-hippocampal and hippocampal-frontal directions) was evaluated by means of statistical crosscorrelation analysis of spike trains. Crosscorrelations between neuronal spike trains in the delay range of 0-100 ms were explored. It was shown that the number of crosscorrelations between the neuronal discharges both in the local and distributed networks was significantly higher in the "self-control" cats. It was suggested that the local and distributed neural networks of the frontal cortex and hippocampus are involved in the system of brain structures which determine the behavioral strategy of animals in the "self-control" group.

  11. QCD corrections to leptonic and hadronic observables from p bar p→W+X→ bar τντX

    International Nuclear Information System (INIS)

    Baer, H.; Reno, M.H.

    1993-01-01

    We set up a formalism for calculating the O(α s ) corrections to the process p bar p→W + X→ bar τν τ X with spin-correlated τ decays to leptons and mesons. Our results are applicable to Monte Carlo integration, which allows easy construction of any desired observable at next-to-leading-log level, and the possibility to include experimental cuts. Our results are applied explicitly to the decay modes τ→ bar ν τ bar eν e , bar τ→ bar ν τ π + , and bar τ→ bar ν τ π + π 0 ; other decay modes may be included in a straightforward fashion. We show results for transverse momentum and rapidity variables in leading-log and next-to-leading-log approximations; the leptonic observables are compared to similar observables from direct W→ bar eν e

  12. Bar quenching in gas-rich galaxies

    Science.gov (United States)

    Khoperskov, S.; Haywood, M.; Di Matteo, P.; Lehnert, M. D.; Combes, F.

    2018-01-01

    Galaxy surveys have suggested that rapid and sustained decrease in the star-formation rate (SFR), "quenching", in massive disk galaxies is frequently related to the presence of a bar. Optical and near-IR observations reveal that nearly 60% of disk galaxies in the local universe are barred, thus it is important to understand the relationship between bars and star formation in disk galaxies. Recent observational results imply that the Milky Way quenched about 9-10 Gyr ago, at the transition between the cessation of the growth of the kinematically hot, old, metal-poor thick disk and the kinematically colder, younger, and more metal-rich thin disk. Although perhaps coincidental, the quenching episode could also be related to the formation of the bar. Indeed the transfer of energy from the large-scale shear induced by the bar to increasing turbulent energy could stabilize the gaseous disk against wide-spread star formation and quench the galaxy. To explore the relation between bar formation and star formation in gas rich galaxies quantitatively, we simulated gas-rich disk isolated galaxies. Our simulations include prescriptions for star formation, stellar feedback, and for regulating the multi-phase interstellar medium. We find that the action of stellar bar efficiently quenches star formation, reducing the star-formation rate by a factor of ten in less than 1 Gyr. Analytical and self-consistent galaxy simulations with bars suggest that the action of the stellar bar increases the gas random motions within the co-rotation radius of the bar. Indeed, we detect an increase in the gas velocity dispersion up to 20-35 km s-1 at the end of the bar formation phase. The star-formation efficiency decreases rapidly, and in all of our models, the bar quenches the star formation in the galaxy. The star-formation efficiency is much lower in simulated barred compared to unbarred galaxies and more rapid bar formation implies more rapid quenching.

  13. Re-study of the contribution of scalar potential and spectra of cc-bar, bb-bar and bc-bar(b-bar c) families

    International Nuclear Information System (INIS)

    Yuan Xuhao; Ke Hongwei; Ding Yibing; Li Xueqian

    2012-01-01

    We indicated in our previous work that for QED the role of the scalar potential which appears at the loop level is much smaller than that of the vector potential and is in fact negligible. But the situation is different for QCD, one reason is that the loop effects are more significant because α s is much larger than α, and second the non-perturbative QCD effects may induce a sizable scalar potential. In this work, we study phenomenologically the contribution of the scalar potential to the spectra of charmonia, bottomonia and bc-bar (b-bar c) families. Taking into account both vector and scalar potentials, by fitting the well measured charmonia and bottomonia spectra, we re-fix the relevant parameters and test them by calculating other states of not only the charmonia and bottomonia families, but also the bc-bar family. We also consider the Lamb shift of the spectra. (authors)

  14. Strength and durability of near-surface mounted CFRP bars for shear strengthening reinforced concrete bridge girders : appendices.

    Science.gov (United States)

    2012-01-01

    During the interstate expansion of the 1950s, many conventionally reinforced concrete deck girder bridges were built throughout the country. These aging bridges commonly exhibit diagonal cracking and rate inadequately for shear, thus they are candida...

  15. Star formation suppression and bar ages in nearby barred galaxies

    Science.gov (United States)

    James, P. A.; Percival, S. M.

    2018-03-01

    We present new spectroscopic data for 21 barred spiral galaxies, which we use to explore the effect of bars on disc star formation, and to place constraints on the characteristic lifetimes of bar episodes. The analysis centres on regions of heavily suppressed star formation activity, which we term `star formation deserts'. Long-slit optical spectroscopy is used to determine H β absorption strengths in these desert regions, and comparisons with theoretical stellar population models are used to determine the time since the last significant star formation activity, and hence the ages of the bars. We find typical ages of ˜1 Gyr, but with a broad range, much larger than would be expected from measurement errors alone, extending from ˜0.25 to >4 Gyr. Low-level residual star formation, or mixing of stars from outside the `desert' regions, could result in a doubling of these age estimates. The relatively young ages of the underlying populations coupled with the strong limits on the current star formation rule out a gradual exponential decline in activity, and hence support our assumption of an abrupt truncation event.

  16. Barred Owl [ds8

    Data.gov (United States)

    California Natural Resource Agency — These data define the current range of Barred and hybrid Barred/Spotted Owls in California. The current range includes the coastal mountains of northern California...

  17. Fabrication of a smart air intake structure using shape memory alloy wire embedded composite

    International Nuclear Information System (INIS)

    Jung, Beom-Seok; Kim, Min-Saeng; Kim, Ji-Soo; Kim, Yun-Mi; Lee, Woo-Yong; Ahn, Sung-Hoon

    2010-01-01

    Shape memory alloys (SMAs) have been actively studied in many fields utilizing their high energy density. Applying SMA wire-embedded composite to aerospace structures, such as air intake of jet engines and guided missiles, is attracting significant attention because it could generate a comparatively large actuating force. In this research, a scaled structure of SMA wire-embedded composite was fabricated for the air intake of aircraft. The structure was composed of several prestrained Nitinol (Ni-Ti) SMA wires embedded in intersection -shape glass fabric reinforced plastic (GFRP), and it was cured at room temperature for 72 h. The SMA wire-embedded GFRP could be actuated by applying electric current through the embedded SMA wires. The activation angle generated from the composite structure was large enough to make a smart air intake structure.

  18. Galaxy Zoo: Observing secular evolution through bars

    International Nuclear Information System (INIS)

    Cheung, Edmond; Faber, S. M.; Koo, David C.; Athanassoula, E.; Bosma, A.; Masters, Karen L.; Nichol, Robert C.; Melvin, Thomas; Bell, Eric F.; Lintott, Chris; Schawinski, Kevin; Skibba, Ramin A.; Willett, Kyle W.

    2013-01-01

    In this paper, we use the Galaxy Zoo 2 data set to study the behavior of bars in disk galaxies as a function of specific star formation rate (SSFR) and bulge prominence. Our sample consists of 13,295 disk galaxies, with an overall (strong) bar fraction of 23.6% ± 0.4%, of which 1154 barred galaxies also have bar length (BL) measurements. These samples are the largest ever used to study the role of bars in galaxy evolution. We find that the likelihood of a galaxy hosting a bar is anticorrelated with SSFR, regardless of stellar mass or bulge prominence. We find that the trends of bar likelihood and BL with bulge prominence are bimodal with SSFR. We interpret these observations using state-of-the-art simulations of bar evolution that include live halos and the effects of gas and star formation. We suggest our observed trends of bar likelihood with SSFR are driven by the gas fraction of the disks, a factor demonstrated to significantly retard both bar formation and evolution in models. We interpret the bimodal relationship between bulge prominence and bar properties as being due to the complicated effects of classical bulges and central mass concentrations on bar evolution and also to the growth of disky pseudobulges by bar evolution. These results represent empirical evidence for secular evolution driven by bars in disk galaxies. This work suggests that bars are not stagnant structures within disk galaxies but are a critical evolutionary driver of their host galaxies in the local universe (z < 1).

  19. Field observations of nearshore bar formation

    DEFF Research Database (Denmark)

    Aagaard, Troels; Kroon, Aart; Greenwood, Brian

    2008-01-01

      The formation of an inner nearshore bar was observed during a high-energy event at the sandy beach of Vejers, Denmark. The bar accreted in situ during surf zone conditions and the growth of the bar was associated with the development of a trough landward of the bar. Measurements of hydrodynamics...

  20. Bar and Theta Hyperoperations

    Directory of Open Access Journals (Sweden)

    Thomas Vougiouklis

    2011-12-01

    Full Text Available In questionnaires the replacement of the scale of Likert by a bar was suggested in 2008 by Vougiouklis & Vougiouklis. The use of the bar was rapidly accepted in social sciences. The bar is closely related with fuzzy theory and has several advantages during both the filling-in questionnaires and mainly in the research processing. In this paper we relate hyperstructure theory with questionnaires and we study the obtained hyperstructures which are used as an organising device of the problem.

  1. Measurement of the $\\bar{p}p \\rightarrow \\bar{n}n$ Charge-Exchange Differential Cross-Section

    CERN Multimedia

    2002-01-01

    The aim of this proposal is a measurement of the differential cross-section of the $\\bar{p}$p $\\rightarrow$ $\\bar{n}$n charge-exchange reaction with a point-to-point precision of 1\\% in the forward direction, and an absolute normalization error of 3\\%. The high precision of the data should allow, inter alia, a determination of the $\\pi$NN coupling constant to better than 2\\%.\\\\ \\\\ The measurement will be done using the existing neutron and antineutron detectors built for experiment PS199 and liquid hydrogen target. In one week of running time, with a $\\bar{p}$ beam intensity of 3 $ 10 ^{5} $ $\\bar{p}$/sec, the reaction will be measured at a few $\\bar{p}$ momenta, in the range 500 to 900~MeV/c.

  2. Reinforced concrete tomography; Tomografia de hormigon armado

    Energy Technology Data Exchange (ETDEWEB)

    Mariscotti, M A.J.; Morixe, M; Tarela, P A; Thieberger, P [Tomografia de Hormigon Armado S.A., Boulogne (Argentina)

    1998-12-31

    In this paper we describe the technique of reinforced concrete tomography, its historical background, recent technological developments and main applications. Gamma radiation sensitive plates are imprinted with radiation going through the concrete sample under study, and then processed to reveal the presence of reinforcement and defects in the material density. The three dimensional reconstruction, or tomography, of the reinforcement out of a single gammagraphy is an original development alternative to conventional methods. Re-bar diameters and positions may be determined with an accuracy of {+-} 1 mm 0.5-1 cm, respectively. The non-destructive character of this technique makes it particularly attractive in cases of inhabited buildings and diagnoses of balconies. (author) 8 refs., 12 figs. [Espanol] En este trabajo se describe la tecnica de tomografia de hormigon armado, sus antededentes, recientes desarrollos y aplicaciones mas importantes. Esta tecnica se basa en el uso de radiacion gamma para penetrar piezas de hormigon. Placas gammagraficas son sensibilizadas con la radiacion que atraviesa la pieza bajo estudio y luego procesadas para revelar la presencia de armadura e inhomogeneidades en la densidad del concreto. La reconstruccion tridimensional o tomografia, de la armadura a partir de una sola gammagrafia es un desarrollo original alternativo a los metodos convencionales. Diametros y posiciones de los hierros existentes en el interior de columnas, vigas y losas pueden ser determinados con precisiones de {+-} 1 mm y 0.5-1 cm, respectivamente. La condicion de no destructiva hace que esta tecnica sea particularmente apreciada en los casos de edificios habitados y sea insustituible para el diagnostico de balcones. (autor)

  3. Damage characterization of E-glass and C-glass fibre polymer composites after high velocity impact

    Science.gov (United States)

    Razali, N.; Sultan, M. T. H.; Cardona, F.; Jawaid, M.

    2017-12-01

    The purpose of this work is to identify impact damage on glass fibre reinforced polymer composite structures after high velocity impact. In this research, Type C-glass (600 g/m2) and Type E-glass (600 g/m2) were used to fabricate Glass Fibre-Reinforced Polymer composites (GFRP) plates. The panels were fabricated using a vacuum bagging and hot bounder method. Single stage gas gun (SSGG) was used to do the testing and data acquisition system was used to collect the damage data. Different types of bullets and different pressure levels were used for the experiment. The obtained results showed that the C-glass type of GFRP experienced more damage in comparison to E-glass type of materials based on the amount of energy absorbed on impact and the size of the damage area. All specimens underwent a partial fibre breakage but the laminates were not fully penetrated by the bullets. This indicated that both types of materials have high impact resistance even though the applied pressures of the gas gun were on the high range. We concluded that within the material specifications of the laminates including the type of glass fibre reinforcement and the thickness of the panels, those composite materials are safe to be applied in structural and body armour applications as an alternative to more expensive materials such as Kevlar and type S-glass fibre based panels.

  4. Nuss bar migrations: occurrence and classification

    International Nuclear Information System (INIS)

    Binkovitz, Lauren E.; Binkovitz, Larry A.; Zendejas, Benjamin; Moir, Christopher R.

    2016-01-01

    Pectus excavatum results from dorsal deviation of the sternum causing narrowing of the anterior-posterior diameter of the chest. It can result in significant cosmetic deformities and cardiopulmonary compromise if severe. The Nuss procedure is a minimally invasive technique that involves placing a thin horizontally oriented metal bar below the dorsal sternal apex for correction of the pectus deformity. To identify the frequency and types of Nuss bar migrations, to present a new categorization of bar migrations, and to present examples of true migrations and pseudomigrations. We retrospectively reviewed the electronic medical records and all pertinent radiologic studies of 311 pediatric patients who underwent a Nuss procedure. We evaluated the frequency and type of bar migrations. Bar migration was demonstrated in 23 of 311 patients (7%) and occurred within a mean period of 26 days after surgery. Bar migrations were subjectively defined as deviation of the bar from the position demonstrated on the immediate postoperative radiographs and categorized as superior, inferior, rotation, lateral or flipped using a new classification system. Sixteen of the 23 migrations required re-operation. Nuss bar migration can be diagnosed with careful evaluation of serial radiographs. Nuss bar migration has a wide variety of appearances and requires exclusion of pseudomigration resulting from changes in patient positioning between radiologic examinations. (orig.)

  5. Nuss bar migrations: occurrence and classification

    Energy Technology Data Exchange (ETDEWEB)

    Binkovitz, Lauren E.; Binkovitz, Larry A. [Mayo Clinic, Department of Radiology, Rochester, MN (United States); Zendejas, Benjamin; Moir, Christopher R. [Mayo Clinic, Department of Surgery, Rochester, MN (United States)

    2016-12-15

    Pectus excavatum results from dorsal deviation of the sternum causing narrowing of the anterior-posterior diameter of the chest. It can result in significant cosmetic deformities and cardiopulmonary compromise if severe. The Nuss procedure is a minimally invasive technique that involves placing a thin horizontally oriented metal bar below the dorsal sternal apex for correction of the pectus deformity. To identify the frequency and types of Nuss bar migrations, to present a new categorization of bar migrations, and to present examples of true migrations and pseudomigrations. We retrospectively reviewed the electronic medical records and all pertinent radiologic studies of 311 pediatric patients who underwent a Nuss procedure. We evaluated the frequency and type of bar migrations. Bar migration was demonstrated in 23 of 311 patients (7%) and occurred within a mean period of 26 days after surgery. Bar migrations were subjectively defined as deviation of the bar from the position demonstrated on the immediate postoperative radiographs and categorized as superior, inferior, rotation, lateral or flipped using a new classification system. Sixteen of the 23 migrations required re-operation. Nuss bar migration can be diagnosed with careful evaluation of serial radiographs. Nuss bar migration has a wide variety of appearances and requires exclusion of pseudomigration resulting from changes in patient positioning between radiologic examinations. (orig.)

  6. Autogenous healing and reinforcement corrosion of water-penetrated separation cracks in reinforced concrete

    International Nuclear Information System (INIS)

    Ramm, W.; Biscoping, M.

    1998-01-01

    Depending on the crack width, the thickness of the structure, the water pressure, and the degree of acid of the water, long-term investigations have been performed over a period of 2 years with respect to the autogenous healing and reinforcement corrosion of water-penetrated separation cracks in reinforced concrete by the University of Kaiserslautern, supported by the Deutsche Forschungsgemeinschaft (DFG). For the waters penetrating the cracks deionised water (neutral, pH=7.0), and boric acid treated deionised water with a pH-value of 6.1 and 5.2 (weakly acid waters) were used. A complete autogenous healing could not be observed. The water penetrating the cracks could hardly be measured with a pH-value of 7.0 at the end of the test. While naturally at the beginning of the test, no influence of the water-chemical degree of the acids could be determined, the existing flow-through quantities towards the end of the test period depended clearly on the crack width and the pH-value. With an increasing crack width and an increasing acid-degree larger flow-through quantities were measured. Depending on the pH-value and the crack width it was determined whether and to which extent corrosion developed at the reinforcing steel bars crossing the cracks. With a crack width of 0.1 mm, corrosion was not to be observed in any case. For the test specimens with a crack width of 0.2 mm a start of the corrosion was found depending on the pH-value. With an increasing width of the crack, an increasing corrosion development is to be expected for test specimens penetrated by acid water. For a crack width of 0.4 mm and a pH-value of 5.2, the highest corrosion development was to be observed, however, there were weakenings of the cross section not worth being mentioned even after a 2-year test period. (orig.)

  7. Passivating action of an organic inhibitor on the steel of reinforced concrete

    International Nuclear Information System (INIS)

    Anzola, E.; Malave, R.; Barrios, V.; Villarroel, D.; Tiso, A.; Parra, M.

    2003-01-01

    An electrochemical evaluation has been made on a concrete mix with an organic inhibitor added, in order to establish its contribution to the formation of a protective film on the steel surface. Concrete cylinders (6''x ), each with a 3/8 steel bar and two graphite electrodes embedded, with two water/cement ratios (0.40 and 0.55) were used as testing samples. Reinforced steel bars, both chemically cleaned and in the as rolled condition, embedded in salted and unsalted concrete mixes, were used to test if chemical adsorption occurs in each condition. Samples were soaked into brine solution during 365 days as to simulate a sea environment. During exposure period readings of potential, corrosion rate and potentiodynamical cyclic curves were made. It can be, concluded that the organic inhibitor needs a low water(cement ratio mix (0.40) in order to react via a chemical adsorption on the steel, being more effective on cleaned surfaces. (Author) 10 refs

  8. Fracture Behaviours in Compression-loaded Triangular Corrugated Core Sandwich Panels

    Directory of Open Access Journals (Sweden)

    Zaid N.Z.M.

    2016-01-01

    Full Text Available The failure modes occurring in sandwich panels based on the corrugations of aluminium alloy, carbon fibre-reinforced plastic (CFRP and glass fibre-reinforced plastic (GFRP are analysed in this work. The fracture behaviour of these sandwich panels under compressive stresses is determined through a series of uniform lateral compression performed on samples with different cell wall thicknesses. Compression test on the corrugated-core sandwich panels were conducted using an Instron series 4505 testing machine. The post-failure examinations of the corrugated-core in different cell wall thickness were conducted using optical microscope. Load-displacement graphs of aluminium alloy, GFRP and CFRP specimens were plotted to show progressive damage development with five unit cells. Four modes of failure were described in the results: buckling, hinges, delamination and debonding. Each of these failure modes may dominate under different cell wall thickness or loading condition, and they may act in combination. The results indicate that thicker composites corrugated-core panels tend can recover more stress and retain more stiffness. This analysis provides a valuable insight into the mechanical behaviour of corrugated-core sandwich panels for use in lightweight engineering applications.

  9. Barred spiral structure of galaxies

    International Nuclear Information System (INIS)

    Chen, Z.; Weng, s.; Xu, M.

    1982-01-01

    Observational data indicate the grand design of spiral or barred spiral structure in disk galaxies. The problem of spiral structure has been thoroughly investigated by C. C. Lin and his collaborators, but yet the problem of barred spiral structure has not been investigated systematically, although much work has been done, such as in Ref. 3--7. Using the gasdynamic model for galaxies and a method of integral transform presented in Ref. 1, we investigated the barred spiral structure and obtained an analytical solution. It gives the large-scale pattern of barred-spirals, which is in fairly good agreement with observational data

  10. Management of corrosion control of reinforced concrete in the channel tunnel; Kaiyo tunnel no tekkin concrete no bosyoku kanri to unei

    Energy Technology Data Exchange (ETDEWEB)

    Poubaix, A. [Centre Belge d`Etude de La Corrosion, Bruxelles (Belgium); Cargo, S. [Eurotunnel Operation, Folkstone (United Kingdom)

    1994-12-15

    This paper reports, upon describing the summary of design and construction of Eurotunnel, the contents of the discussions carried out by the Brussels Corrosion Research Center, and their results. Circulating oxygen is supplied sufficiently, and the temperature and humidity are kept high in the tunnel in operation, whereas intermittent dryness may occur locally due to strong air circulation caused by a passing train. While corrosion may occur in any of the reinforcing bars, steel frames, or concrete, the basic corrosion mechanism includes pH decrease in concrete due to its carbonatization, cracking and damage in the concrete, and stray current effect. Detailed discussions were given on experiences of building offshore structures in every part of the world. A possibility of the tunnel getting corroded in 50 to 60 years due to de-passivation in reinforcing bars was indicated against the assumed usable life of 120 years. Therefore, cathodic protection and corrosion monitoring were studied, whereby a unique system was proposed to identify hazardous zones, grasp and analyze data concentratedly. 24 refs., 8 figs., 1 tab.

  11. Failure of policy regarding smoke-free bars in the Netherlands.

    Science.gov (United States)

    Gonzalez, Mariaelena; Glantz, Stanton A

    2013-02-01

    Tobacco companies consistently work to prevent and undermine smoke-free laws. The tobacco industry and its allies have funded hospitality associations and other third parties to oppose smoke-free laws, argue that smoke-free laws will economically damage hospitality venues, promote ventilation and voluntary smoker 'accommodation' as an alternative to smoke-free laws, and to challenge smoke-free laws in court. In 2008, the Netherlands extended its smoke-free law to hospitality venues. We triangulated news articles, government documents, scientific papers, statistical reports and interviews to construct this case study. Despite widespread public support for smoke-free hospitality venues, opponents successfully represented these laws as unpopular and damaging to small bars. These challenges and related smokers' rights activities resulted in non-compliance among all bars and reinstating an exemption for small, owner-run venues. This policy reversal was the result of a weak implementing media campaign (which failed to present the law as protecting nonsmokers), smoking room exemptions and reactive (vs. proactive) measures by the Ministry of Health and civil society. The policy failure in the Netherlands is the result of poor implementation efforts and the failure to anticipate and deal with opposition to the law. When implementing smoke-free laws it is important to anticipate opposition, used the media to target non-smokers to reinforce public support, and actively enforce the law.

  12. Failure of policy regarding smoke-free bars in the Netherlands*

    Science.gov (United States)

    Gonzalez, Mariaelena

    2013-01-01

    Background: Tobacco companies consistently work to prevent and undermine smoke-free laws. The tobacco industry and its allies have funded hospitality associations and other third parties to oppose smoke-free laws, argue that smoke-free laws will economically damage hospitality venues, promote ventilation and voluntary smoker ‘accommodation’ as an alternative to smoke-free laws, and to challenge smoke-free laws in court. In 2008, the Netherlands extended its smoke-free law to hospitality venues. Methods: We triangulated news articles, government documents, scientific papers, statistical reports and interviews to construct this case study. Results: Despite widespread public support for smoke-free hospitality venues, opponents successfully represented these laws as unpopular and damaging to small bars. These challenges and related smokers’ rights activities resulted in non-compliance among all bars and reinstating an exemption for small, owner-run venues. This policy reversal was the result of a weak implementing media campaign (which failed to present the law as protecting nonsmokers), smoking room exemptions and reactive (vs. proactive) measures by the Ministry of Health and civil society. Conclusion: The policy failure in the Netherlands is the result of poor implementation efforts and the failure to anticipate and deal with opposition to the law. When implementing smoke-free laws it is important to anticipate opposition, used the media to target non-smokers to reinforce public support, and actively enforce the law. PMID:22143826

  13. Too Much Bar and Not Enough Mitzvah? A Proposed Research Agenda on Bar/Bat Mitzvah

    Science.gov (United States)

    Schoenfeld, Stuart

    2010-01-01

    Jewish educators are understandably interested in research on how bar/bat mitzvah affect Jewish education or research on what Jewish schools have done to avoid the distortions of a focus on bar/bat mitzvah. Research might also focus on the somewhat different and more ambitious topic of the role that bar/bat mitzvah play in contemporary Jewish…

  14. Measurement and Interpretation of Moments in Inclusive Semileptonic Decays (bar B) → Xc (ell)-(bar ν)

    International Nuclear Information System (INIS)

    Luth, Vera

    2011-01-01

    We present results for the moments of observed spectra in inclusive semileptonic B-meson decays to charm hadrons (bar B) → X c (ell) - (bar ν). Moments of the hadronic-mass and the combined mass-and-energy spectra for different minimum electron or muon momenta between 0.8 and 1.9 GeV/c are obtained from a sample of 232 x 10 6 Γ(4S) → B(bar B) events, collected with the BABAR detector at the PEP-II asymmetric-energy B-meson factory at SLAC. We also present a reevaluation of the moments of electron-energy spectra and partial decay fractions B((bar B) → X c e - (bar ν)) for minimum electron momenta between 0.6 and 1.5 GeV/c based on a sample of 51 x 10 6 Γ(4S) → B(bar B) events. The measurements are used for the extraction of the total decay fraction, the Cabibbo-Kobayashi-Maskawa (CKM) matrix element |V cb |, the quark masses m b and m c , and four heavy-quark QCD parameters in the framework of a Heavy-Quark Expansion (HQE). We find B((bar B) → X c (ell) - (bar ν)) = (10.64 ± 0.17 ± 0.06)% and |V cb | = (42.05 ± 0.45 ± 0.70) x 10 -3 .

  15. Determination of concrete cover thickness in a reinforced concrete pillar by observation of the scattered electromagnetic field

    Science.gov (United States)

    Di Gregorio, Pietro Paolo; Frezza, Fabrizio; Mangini, Fabio; Pajewski, Lara

    2017-04-01

    The electromagnetic scattered field by a reinforced concrete structure is calculated by means of frequency-domain numerical simulations and by making use of the scattered-field formulation. The concrete pillar, used as supporting architectural element, is modelled as a parallelepiped shell made of concrete material inside which are present steel bars. In order to make the model simpler, the steel bars are supposed running parallel to the air-pillar interface. To excite the model, a linearly-polarized plane wave impinging normally with respect to the pillars surface, is adopted. We consider two different polarizations in order to determine the most useful in terms of scattered-field sensitivity. Moreover, a preliminary frequency sweep allows us to choose the most suitable operating frequency depending on the dimensions of the pillar cross-section, the steel bars cross-section and the concrete cover. All the three components of the scattered field are monitored along a line just above the interface air-pillar. The electromagnetic properties of the materials employed in this study are present in the literature and, since a frequency-domain technique is adopted, no further approximation is needed. The results obtained for different values of the concrete cover are compared, with the goal of determining the scattered field dependence on the concrete cover thickness. Considering different concrete cover thicknesses, we want to provide an electromagnetic method to obtain this useful parameter by observation of the scattered electromagnetic field. One of the practical applications of this study in the field of Civil Engineering may be the use of ground penetrating radar (GPR) techniques to monitor the thickness of the concrete that separates the metal bars embedded in the pillar from the outer surface. A correct distance is useful because the concrete cover serves as a protection against external agents avoiding corrosion of the bars that might prejudice the reinforced

  16. Expandable antivibration bar for a steam generator

    International Nuclear Information System (INIS)

    Lagally, H.O.

    1986-01-01

    A steam generator tube support structure comprises expandable antivibration bars positioned between rows of tubes in the steam generator and attached to retaining rings surrounding the bundle of tubes. The antivibration bars have adjacent bar sections with mating surfaces formed as inclined planes which upon relative longitudinal motion between the upper and lower bars provides a means to increase the overall thickness across the structure to the required value. The bar section is retained against longitudinal movement in take-up assembly whereas the bar section is movable longitudinally by rotation of a nut. (author)

  17. Study of J/psi -> p(p)over-bar and J/psi -> n(n)over-bar

    NARCIS (Netherlands)

    Ablikim, M.; Achasov, M. N.; Ambrose, D. J.; An, F. F.; An, Q.; An, Z. H.; Bai, J. Z.; Ban, Y.; Becker, J.; Berger, N.; Bertani, M.; Bian, J. M.; Boger, E.; Bondarenko, O.; Boyko, I.; Briere, R. A.; Bytev, V.; Cai, X.; Calcaterra, A.; Cao, G. F.; Chang, J. F.; Chelkov, G.; Chen, G.; Chen, H. S.; Chen, J. C.; Chen, M. L.; Chen, S. J.; Chen, Y.; Chen, Y. B.; Cheng, H. P.; Chu, Y. P.; Cronin-Hennessy, D.; Dai, H. L.; Dai, J. P.; Dedovich, D.; Deng, Z. Y.; Denig, A.; Denysenko, I.; Destefanis, M.; Ding, W. M.; Ding, Y.; Dong, L. Y.; Dong, M. Y.; Du, S. X.; Fang, J.; Fang, S. S.; Fava, L.; Feldbauer, F.; Feng, C. Q.; Ferroli, R. B.; Fu, C. D.; Fu, J. L.; Gao, Y.; Geng, C.; Goetzen, K.; Gong, W. X.; Gradl, W.; Greco, M.; Gu, M. H.; Gu, Y. T.; Guan, Y. H.; Guo, A. Q.; Guo, L. B.; Guo, Y. P.; Han, Y. L.; Hao, X. Q.; Harris, F. A.; He, K. L.; He, M.; He, Z. Y.; Held, T.; Heng, Y. K.; Hou, Z. L.; Hu, H. M.; Hu, J. F.; Hu, T.; Huang, B.; Huang, G. M.; Huang, J. S.; Huang, X. T.; Huang, Y. P.; Hussain, T.; Ji, C. S.; Ji, Q.; Ji, X. B.; Ji, X. L.; Jia, L. K.; Jiang, L. L.; Jiang, X. S.; Jiao, J. B.; Jiao, Z.; Jin, D. P.; Jin, S.; Jing, F. F.; Kalantar-Nayestanaki, N.; Kavatsyuk, M.; Kuehn, W.; Lai, W.; Lange, J. S.; Leung, J. K. C.; Li, C. H.; Li, Cheng; Li, Cui; Li, D. M.; Li, F.; Li, G.; Li, H. B.; Li, J. C.; Li, K.; Li, Lei; Li, N. B.; Li, Q. J.; Li, S. L.; Li, W. D.; Li, W. G.; Li, X. L.; Li, X. N.; Li, X. Q.; Li, X. R.; Li, Z. B.; Liang, H.; Liang, Y. F.; Liang, Y. T.; Liao, G. R.; Liao, X. T.; Liu, B. J.; Liu, B. J.; Liu, C. L.; Liu, C. X.; Liu, C. Y.; Liu, F. H.; Liu, Fang; Liu, Feng; Liu, H.; Liu, H. B.; Liu, H. H.; Liu, H. M.; Liu, H. W.; Liu, J. P.; Liu, K. Y.; Liu, Kai; Liu, Kun; Liu, P. L.; Liu, S. B.; Liu, X.; Liu, X. H.; Liu, Y.; Liu, Y. B.; Liu, Z. A.; Liu, Zhiqiang; Liu, Zhiqing; Loehner, H.; Lu, G. R.; Lu, H. J.; Lu, J. G.; Lu, Q. W.; Lu, X. R.; Lu, Y. P.; Luo, C. L.; Luo, M. X.; Luo, T.; Luo, X. L.; Lv, M.; Ma, C. L.; Ma, F. C.; Ma, H. L.; Ma, Q. M.; Ma, S.; Ma, T.; Ma, X. Y.; Ma, Y.; Maas, F. E.; Maggiora, M.; Malik, Q. A.; Mao, H.; Mao, Y. J.; Mao, Z. P.; Messchendorp, J. G.; Min, J.; Min, T. J.; Mitchell, R. E.; Mo, X. H.; Morales, C. Morales; Motzko, C.; Muchnoi, N. Yu.; Nefedov, Y.; Nicholson, C.; Nikolaev, I. B.; Ning, Z.; Olsen, S. L.; Ouyang, Q.; Pacetti, S.; Park, J. W.; Pelizaeus, M.; Peters, K.; Ping, J. L.; Ping, R. G.; Poling, R.; Prencipe, E.; Pun, C. S. J.; Qi, M.; Qian, S.; Qiao, C. F.; Qin, X. S.; Qin, Y.; Qin, Z. H.; Qiu, J. F.; Rashid, K. H.; Rong, G.; Ruan, X. D.; Sarantsev, A.; Schulze, J.; Shao, M.; Shen, C. P.; Shen, X. Y.; Sheng, H. Y.; Shepherd, M. R.; Song, X. Y.; Spataro, S.; Spruck, B.; Sun, D. H.; Sun, G. X.; Sun, J. F.; Sun, S. S.; Sun, X. D.; Sun, Y. J.; Sun, Y. Z.; Sun, Z. J.; Sun, Z. T.; Tang, C. J.; Tang, X.; Thorndike, E. H.; Tian, H. L.; Toth, D.; Ullrich, M.; Varner, G. S.; Wang, B.; Wang, B. Q.; Wang, K.; Wang, L. L.; Wang, L. S.; Wang, M.; Wang, P.; Wang, P. L.; Wang, Q.; Wang, Q. J.; Wang, S. G.; Wang, X. F.; Wang, X. L.; Wang, Y. D.; Wang, Y. F.; Wang, Y. Q.; Wang, Z.; Wang, Z. G.; Wang, Z. Y.; Wei, D. H.; Weidenkaff, P.; Wen, Q. G.; Wen, S. P.; Werner, M.; Wiedner, U.; Wu, L. H.; Wu, N.; Wu, S. X.; Wu, W.; Wu, Z.; Xia, L. G.; Xiao, Z. J.; Xie, Y. G.; Xiu, Q. L.; Xu, G. F.; Xu, G. M.; Xu, H.; Xu, Q. J.; Xu, X. P.; Xu, Y.; Xu, Z. R.; Xue, F.; Xue, Z.; Yan, L.; Yan, W. B.; Yan, Y. H.; Yang, H. X.; Yang, T.; Yang, Y.; Yang, Y. X.; Ye, H.; Ye, M.; Ye, M. H.; Yu, B. X.; Yu, C. X.; Yu, J. S.; Yu, S. P.; Yuan, C. Z.; Yuan, W. L.; Yuan, Y.; Zafar, A. A.; Zallo, A.; Zeng, Y.; Zhang, B. X.; Zhang, B. Y.; Zhang, C. C.; Zhang, D. H.; Zhang, H. H.; Zhang, H. Y.; Zhang, J.; Zhang, J. G.; Zhang, J. Q.; Zhang, J. W.; Zhang, J. Y.; Zhang, J. Z.; Zhang, L.; Zhang, S. H.; Zhang, T. R.; Zhang, X. J.; Zhang, X. Y.; Zhang, Y.; Zhang, Y. H.; Zhang, Y. S.; Zhang, Z. P.; Zhang, Z. Y.; Zhao, G.; Zhao, H. S.; Zhao, J. W.; Zhao, K. X.; Zhao, Lei; Zhao, Ling; Zhao, M. G.; Zhao, Q.; Zhao, S. J.; Zhao, T. C.; Zhao, X. H.; Zhao, Y. B.; Zhao, Z. G.; Zhemchugov, A.; Zheng, B.; Zheng, J. P.; Zheng, Y. H.; Zheng, Z. P.; Zhong, B.; Zhong, J.; Zhou, L.; Zhou, X. K.; Zhou, X. R.; Zhu, C.; Zhu, K.; Zhu, K. J.; Zhu, S. H.; Zhu, X. L.; Zhu, X. W.; Zhu, Y. M.; Zhu, Y. S.; Zhu, Z. A.; Zhuang, J.; Zou, B. S.; Zou, J. H.; Zuo, J. X.

    2012-01-01

    The decays J/psi -> p (p) over bar and J/psi -> n (n) over bar have been investigated with a sample of 225.2 x 10(6) J/psi events collected with the BESIII detector at the BEPCII e(+)e(-) collider. The branching fractions are determined to be B(J/psi -> p (p) over bar) = (2.112 +/- 0.004 +/- 0.031 x

  18. Modelling of cracking and inelastic behaviour of reinforced concrete structures

    International Nuclear Information System (INIS)

    Young, A.G.; Albana, M.O.

    1989-09-01

    The report contains a review of work available in the literature on local bond transfer and the main factors which influence it, involving deformed reinfocing bar. Possible load transfer mechanisms are investigated and the significance of secondary cracking, local consolidation and shearing assessed. On the basis of these studies a linkage element which realistically models bond action, and is applicable to both monotonic and cyclic load, is proposed. Its ability to accurately predict stress, strain and crack geometry in typical reinforced concrete components is demonstrated by comparison of the results of finite element analysis using this model with experimental data. Aspects requiring further research are identified. An analysis of the dynamic response of a reinforced concrete beam is given which makes the simplifying assumption of rigid-plastic behaviour. A comparison of the analytical solution with experimental results obtained by bend tests in the Large Dynamic Test Facility at Ispra shows that, despite the neglect of elastic vibrations, a reasonable prediction of the fundamental response is obtained providing due allowance is made for rate-of-strain effects

  19. Membrane-sculpting BAR domains generate stable lipid microdomains

    DEFF Research Database (Denmark)

    Zhao, Hongxia; Michelot, Alphée; Koskela, Essi V.

    2013-01-01

    Bin-Amphiphysin-Rvs (BAR) domain proteins are central regulators of many cellular processes involving membrane dynamics. BAR domains sculpt phosphoinositide-rich membranes to generate membrane protrusions or invaginations. Here, we report that, in addition to regulating membrane geometry, BAR...... domains can generate extremely stable lipid microdomains by "freezing" phosphoinositide dynamics. This is a general feature of BAR domains, because the yeast endocytic BAR and Fes/CIP4 homology BAR (F-BAR) domains, the inverse BAR domain of Pinkbar, and the eisosomal BAR protein Lsp1 induced...... phosphoinositide clustering and halted lipid diffusion, despite differences in mechanisms of membrane interactions. Lsp1 displays comparable low diffusion rates in vitro and in vivo, suggesting that BAR domain proteins also generate stable phosphoinositide microdomains in cells. These results uncover a conserved...

  20. Membrane-Sculpting BAR Domains Generate Stable Lipid Microdomains

    Science.gov (United States)

    Zhao, Hongxia; Michelot, Alphée; Koskela, Essi V.; Tkach, Vadym; Stamou, Dimitrios; Drubin, David G.; Lappalainen, Pekka

    2014-01-01

    SUMMARY Bin-Amphiphysin-Rvs (BAR) domain proteins are central regulators of many cellular processes involving membrane dynamics. BAR domains sculpt phosphoinositide-rich membranes to generate membrane protrusions or invaginations. Here, we report that, in addition to regulating membrane geometry, BAR domains can generate extremely stable lipid microdomains by “freezing” phosphoinositide dynamics. This is a general feature of BAR domains, because the yeast endocytic BAR and Fes/CIP4 homology BAR (F-BAR) domains, the inverse BAR domain of Pinkbar, and the eisosomal BAR protein Lsp1 induced phosphoinositide clustering and halted lipid diffusion, despite differences in mechanisms of membrane interactions. Lsp1 displays comparable low diffusion rates in vitro and in vivo, suggesting that BAR domain proteins also generate stable phosphoinositide microdomains in cells. These results uncover a conserved role for BAR superfamily proteins in regulating lipid dynamics within membranes. Stable microdomains induced by BAR domain scaffolds and specific lipids can generate phase boundaries and diffusion barriers, which may have profound impacts on diverse cellular processes. PMID:24055060

  1. Diagnosis of the surface layer damage in a 1960s reinforced concrete building

    Directory of Open Access Journals (Sweden)

    S.L. Pagliolico

    2014-01-01

    Full Text Available This work aimed to determine the degradation causes of the Palace of Public Works located in S. Giovanni square in Turin (Piedmont, Italy. The samples collected from the surface layer were characterized by means of scanning electron microscopy (SEM, X-ray diffraction (XRD, thermogravimetric coupled with differential thermal analysis (TG-DTA, mercury intrusion porosimetry measurements (MIP and phenolphthalein test. Metallographic and elemental analyses were also carried out on the steel reinforcing bars. An exhaustive picture of the main causes of deterioration was drawn in order to design the intervention of rehabilitation.

  2. The BaBar Mini

    International Nuclear Information System (INIS)

    Brown, David N.

    2003-01-01

    BaBar has recently deployed a new event data format referred to as the Mini. The mini uses efficient packing and aggressive noise suppression to represent the average reconstructed BaBar event in under 7 KBytes. The Mini packs detector information into simple transient data objects, which are then aggregated into roughly 10 composite persistent objects per event. The Mini currently uses Objectivity persistence, and it is being ported to use Root persistence. The Mini contains enough information to support detailed detector studies, while remaining small and fast enough to be used directly in physics analysis. Mini output is customizable, allowing users to both truncate unnecessary content or add content, depending on their needs. The Mini has now replaced three older formats as the primary output of BaBar event reconstruction. A reduced form of the Mini will soon replace the physics analysis format as well, giving BaBar a single, flexible event data format covering all its needs

  3. The BaBar mini

    International Nuclear Information System (INIS)

    Brown, David N.; BaBar Collaboration

    2003-01-01

    BaBar has recently deployed a new event data format referred to as the Mini. The mini uses efficient packing and aggressive noise suppression to represent the average reconstructed BaBar event in under 7 KBytes. The Mini packs detector information into simple transient data objects, which are then aggregated into roughly 10 composite persistent objects per event. The Mini currently uses Objectivity persistence, and it is being ported to use Root persistence. The Mini contains enough information to support detailed detector studies, while remaining small and fast enough to be used directly in physics analysis. Mini output is customizable, allowing users to both truncate unnecessary content or add content, depending on their needs. The Mini has now replaced three older formats as the primary output of BaBar event reconstruction. A reduced form of the Mini will soon replace the physics analysis format as well, giving BaBar a single, flexible event data format covering all its needs

  4. A mathematical high bar-human body model for analysing and interpreting mechanical-energetic processes on the high bar.

    Science.gov (United States)

    Arampatzis, A; Brüggemann, G P

    1998-12-01

    The aims of this study were: 1. To study the transfer of energy between the high bar and the gymnast. 2. To develop criteria from the utilisation of high bar elasticity and the utilisation of muscle capacity to assess the effectiveness of a movement solution. 3. To study the influence of varying segment movement upon release parameters. For these purposes a model of the human body attached to the high bar (high bar-human body model) was developed. The human body was modelled using a 15-segment body system. The joint-beam element method (superelement) was employed for modelling the high bar. A superelement consists of four rigid segments connected by joints (two Cardan joints and one rotational-translational joint) and springs (seven rotation springs and one tension-compression spring). The high bar was modelled using three superelements. The input data required for the high bar human body model were collected with video-kinematographic (50 Hz) and dynamometric (500 Hz) techniques. Masses and moments of inertia of the 15 segments were calculated using the data from the Zatsiorsky et al. (1984) model. There are two major phases characteristic of the giant swing prior to dismounts from the high bar. In the first phase the gymnast attempts to supply energy to the high bar-humanbody system through muscle activity and to store this energy in the high bar. The difference between the energy transferred to the high bar and the reduction in the total energy of the body could be adopted as a criterion for the utilisation of high bar elasticity. The energy previously transferred into the high bar is returned to the body during the second phase. An advantageous increase in total body energy at the end of the exercise could only be obtained through muscle energy supply. An index characterising the utilisation of muscle capacity was developed out of the difference between the increase in total body energy and the energy returned from the high bar. A delayed and initially slow but

  5. Material equations for the calculations of steel fiber reinforced concrete members

    International Nuclear Information System (INIS)

    Jonas, W.

    1993-01-01

    Steel fiber reinforced concrete (SFRC) is made by the addition of steel fibers to fresh concrete. Usually the fibers are about 0.4-0.8mm in diameter and 25-80mm long. The addition of about 50-120 kg/m 3 is a practical and useful amount. That is about 0.6-1.5% by volume. The fibers are uniformly dispersed with a suitable concrete mix, so that clusters and uneven concentrations are prevented. The tensile strength of steel fiber reinforced concrete is scarcely better compared to that of plain concrete, but the fibers are very effective at preventing the propagation of tensile cracks. Thereby the tensile strength of fiber reinforced concrete is a reliable value. The addition of steel fibers also leads to a considerable increase of plastic deformations in the post cracking region, in comparison to plain concrete members. For nuclear power plant construction the use of steel fiber concrete with additional reinforcement of normal or prestressing steel is of special interest. The finished members exhibit good crack behaviour, increased shear strength and a considerable ability to absorb mechanical energy. These are valuable properties for members providing protection against extreme load cases (e.g. aircraft crash, earthquake, blast caused by explosion, debris due to hurricane, internal pressure loads or debris due to bursting of vessels or pipes). The behaviour of a reinforced concrete beam with steel fiber reinforced concrete against that of a reinforced beam without is shown. Until now the use of steel fiber reinforced concrete in civil engineering has been restricted because of the lack of design rules. For the preparation of fundamental principles and for the development of design rules HOCHTIEF has undertaken a series of tests on steel fiber reinforced concrete members with and without additional bar reinforcement. For this purpose HOCHTIEF has carried out several series of tests using either static, impact or cyclic loadings. In section 2 of this paper the elements

  6. Experimental analysis of reinforced concrete columns strengthened with self-compacting concrete and connectors

    Directory of Open Access Journals (Sweden)

    P. P. Nascimento

    Full Text Available There are many problems involving cases of destruction of buildings and other structures. The columns can deteriorate for several reasons such as the evolution and changing habits of the loads. The experimental phase of this work was based on a test involving nine reinforced concrete columns under combined bending and axial compression, at an initial eccentricity of 60 mm. Two columns were used as reference, one having the original dimensions of the column and the other, monolithic, had been cast along the thickness of the strengthened piece. The remaining columns received a 35 mm thick layer of self-compacting concrete on their compressed face. For the preparation of the interface between the two materials, this surface was scarified and furrowed and connectors were inserted onto the columns' shear reinforcement in various positions and amounts.As connectors, 5 mm diameter steel bars were used (the same as for stirrups, bent in the shape of a "C" with 25 mm coatings. >As a conclusion, not only the quantity, but mainly, the location of the connectors used in the link between substrate and reinforcement is crucial to increase strength and to change failure mode.

  7. Aluminium EN AW-2124 alloy matrix composites reinforced with Ti(C,N), BN and Al2O3 particles

    International Nuclear Information System (INIS)

    Dobrzanski, L.A.; Wlodarczyk, A.; Adamiak, M.

    2003-01-01

    Investigation results of the aluminium alloy EN AW-2124 matrix composite materials with particles of the powders Ti(C,N), BN and Al 2 O 3 (15 wt.%) are presented in the paper. In order to obtain uniform distribution of reinforcement particles in aluminium alloy matrix powders of composite components have been milled in the rotary ball-bearing pulverizer. The composites have been pressed in laboratory vertical press at room temperature under the pressure of 500 kN. Obtained die samplings have been heated to the temperature 520-550 o C and extruded. Bars of diameter 8 mm have been received as a final product. Metallographic examination of the composites materials' structure shows non-uniform distribution of reinforced powders in the aluminium alloy matrix banding of reinforcements particles corresponds to the extrusion direction. Particles of reinforcement distribution in aluminium alloy matrix is irregular, some agglomerations of powder of aluminium oxide and porosity of different size have been noticed. Investigations of hardness and ultimate compressive strength show that the particles of reinforcement improve mechanical properties of composite materials. Investigations of compressive strength, carried out at room temperature, enable to compare mechanical properties of matrix and composite. (author)

  8. Strength and durability of near-surface mounted CFRP bars for shear strengthening reinforced concrete bridge girders : final report.

    Science.gov (United States)

    2012-03-01

    During the interstate expansion of the 1950s, many conventionally reinforced concrete deck girder bridges were built throughout the country. These aging bridges commonly exhibit diagonal cracking and rate inadequately for shear, thus they are candida...

  9. Measurement of the absolute branching fraction of D-vertical bar -> (K)over-bar(0)e(vertical bar) nu(e) via (K)over-bar(0) -> pi(0)pi(0)

    NARCIS (Netherlands)

    Ablikim, M.; Achasov, N.; Ai, X. C.; Albayrak, O.; Albrecht, M.; Ambrose, D. J.; Amoroso, A.; An, F. F.; An, Q.; Bai, J. Z.; Ferroli, R. Baldini; Ban, Y.; Bennett, D. W.; Bennett, J. V.; Bertani, M.; Bettonin, D.; Bian, J. M.; Bianchi, F.; Boger, E.; Boyko, I.; Briere, R. A.; Cai, H.; Cai, X.; Cakir, O.; Caleaterra, A.; Cao, G. F.; Cetin, S. A.; Chang, J. F.; Chelkov, G.; Chen, G.; Chen, H. S.; Chen, H. Y.; Chen, J. C.; Chen, M. L.; Chen, S.; Chen, S. J.; Chen, X.; Chen, X. R.; Chen, Y. B.; Cheng, H. P.; Chu, X. K.; Cibinetto, G.; Dai, H. L.; Dai, J. P.; Dbeyssi, A.; Dedovich, D.; Deng, Z. Y.; Denig, A.; Denysenko, I.; Destefanis, M.; De Mori, F.; Ding, Y.; Dong, C.; Dong, J.; Dong, L. Y.; Dong, M. Y.; Dou, Z. L.; Du, S. X.; Duan, P. F.; Fan, J. Z.; Fang, J.; Fang, S. S.; Fang, X.; Fang, Y.; Farinelli, R.; Fava, L.; Fedorov, O.; Feldbauer, F.; Felici, G.; Feng, C. Q.; Fioravanti, E.; Fritsch, M.; Fu, C. D.; Gao, Q.; Gao, X. L.; Gao, X. Y.; Gao, Y.; Gao, Z.; Garzia, I.; Goetzen, K.; Gong, L.; Gong, W. X.; Gradl, W.; Greco, M.; Gu, M. H.; Gu, Y. T.; Guan, Y. H.; Guo, A. Q.; Guo, L. B.; Guo, R. P.; Guo, Y.; Guo, Y. P.; Haddadi, Z.; Hafner, A.; Han, S.; Hao, X. Q.; Harris, F. A.; He, K. L.; Held, T.; Heng, Y. K.; Hou, Z. L.; Hu, C.; Hu, H. M.; Hu, J. F.; Hu, T.; Hu, Y.; Huang, G. S.; Huang, J. S.; Huang, X. T.; Huang, X. Z.; Huang, Y.; Huang, Z. L.; Hussain, T.; Ji, Q.; Ji, Q. P.; Ji, X. B.; Ji, X. L.; Jiang, L. W.; Jiang, X. S.; Jiang, X. Y.; Jiao, J. B.; Jiao, Z.; Jin, D. P.; Jin, S.; Johansson, T.; Julin, A.; Kalantar-Nayestanaki, N.; Kang, X. L.; Kang, X. S.; Kavatsyuk, M.; Ke, B. C.; Kiese, P.; Kliemt, R.; Kloss, B.; Kolc, O. B.; Kopf, B.; Kornicer, M.; Kupse, A.; Kuehn, W.; Lange, J. S.; Lara, M.; Larin, P.; Leng, C.; Li, C.; Li, Cheng; Li, D. M.; Li, F.; Li, F. Y.; Li, G.; Li, H. B.; Li, H. J.; Li, J. C.; Li, Jin; Li, K.; Li, K.; Li, Lei; Li, P. R.; Li, Q. Y.; Li, T.; Li, W. D.; Li, W. G.; Li, X. L.; Li, X. N.; Li, X. Q.; Li, Y. B.; Li, Z. B.; Liang, H.; Liang, Y. F.; Liang, Y. T.; Liao, G. R.; Lin, D. X.; Liu, B.; Liu, B. J.; Liu, C. X.; Liu, D.; Liu, F. H.; Liu, Fang; Liu, Feng; Liu, H. B.; Liu, H. H.; Liu, H. H.; Liu, H. M.; Liu, J.; Liu, J. B.; Liu, J. P.; Liu, J. Y.; Liu, K.; Liu, K. Y.; Liu, L. D.; Liu, P. L.; Liu, Q.; Liu, S. B.; Liu, X.; Liu, Y. B.; Liu, Z. A.; Liu, Zhiqing; Loehner, H.; Lou, X. C.; Lu, H. J.; Lu, J. G.; Lu, Y.; Lu, Y. P.; Luo, C. L.; Luo, M. X.; Luo, T.; Luo, X. L.; Lu, X. R.; Ma, F. C.; Ma, H. L.; Ma, L. L.; Ma, M. M.; Ma, Q. M.; Ma, T.; Ma, X. N.; Ma, X. Y.; Ma, Y. M.; Maas, F. E.; Maggiora, M.; Mao, Y. J.; Mao, Z. P.; Marcello, S.; Messchendorp, J. G.; Min, J.; Min, T. J.; Mitchell, R. E.; Mo, X. H.; Mo, Y. J.; Morales, C. Morales; Muchnoi, N. Yu.; Muramatsu, H.; Nefedov, Y.; Nerling, F.; Nikolaev, I. B.; Ning, Z.; Nisar, S.; Niu, S. L.; Niu, X. Y.; Olsen, S. L.; Ouyang, Q.; Pacetti, S.; Pan, Y.; Patteri, P.; Pelizaeus, M.; Peng, H. P.; Peters, K.; Pettersson, J.; Ping, J. L.; Ping, R. G.; Poling, R.; Prasad, V.; Qi, H. R.; Qi, M.; Qian, S.; Qiao, C. F.; Qin, L. Q.; Qin, N.; Qin, X. S.; Qin, Z. H.; Qiu, J. F.; Rashid, K. H.; Redmer, C. F.; Ripka, M.; Rong, G.; Rosner, Ch.; Ruan, X. D.; Sarantsev, A.; Savrie, M.; Schoenning, K.; Schumann, S.; Shan, W.; Shao, M.; Shen, C. P.; Shen, P. X.; Shen, X. Y.; Sheng, H. Y.; Shi, M.; Song, W. M.; Song, X. Y.; Sosio, S.; Spataro, S.; Sun, G. X.; Sun, J. F.; Sun, S. S.; Sun, X. H.; Sun, Y. J.; Sun, Y. Z.; Sun, Z. J.; Sun, Z. T.; Tang, C. J.; Tang, X.; Tapan, I.; Thorndike, E. H.; Tiemens, M.; Ullrich, M.; Uman, I.; Varner, G. S.; Wang, B.; Wang, B. L.; Wang, D.; Wang, D. Y.; Wang, K.; Wang, L. L.; Wang, L. S.; Wang, M.; Wang, P.; Wang, P. L.; Wang, W.; Wang, W. P.; Wang, X. F.; Wang, Y.; Wang, Y. D.; Wang, Y. F.; Wang, Y. Q.; Wang, Z.; Wang, Z. G.; Wang, Z. H.; Wang, Z. Y.; Wang, Z. Y.; Weber, T.; Wei, D. H.; Weidenkaff, P.; Wen, S. P.; Wiedner, U.; Wolke, M.; Wu, L. H.; Wu, L. J.; Wu, Z.; Xia, L.; Xia, Y.; Xiao, D.; Xiao, H.; Xiao, Z. J.; Xie, Y. G.; Xiu, Q. L.; Xu, G. F.; Xu, J. J.; Xu, L.; Xu, Q. J.; Xu, Q. N.; Xu, X. P.; Yan, L.; Yan, W. B.; Yan, W. C.; Yan, Y. H.; Yang, H. J.; Yang, H. X.; Yang, L.; Yang, Y. X.; Ye, M.; Ye, M. H.; Yin, J. H.; Yu, B. X.; Yu, C. X.; Yu, J. S.; Yuan, C. Z.; Yuan, W. L.; Yuan, Y.; Yuncu, A.; Zafar, A. A.; Zallo, A.; Zeng, Y.; Zeng, Z.; Zhang, B. X.; Zhang, B. Y.; Zhang, C.; Zhang, C. C.; Zhang, D. H.; Zhang, H. H.; Zhang, H. Y.; Zhang, J.; Zhang, J. J.; Zhang, J. L.; Zhang, J. Q.; Zhang, J. W.; Zhang, J. Y.; Zhang, J. Z.; Zhang, K.; Zhang, L.; Zhang, S. Q.; Zhang, X. Y.; Zhang, Y.; Zhang, Y. H.; Zhang, Y. N.; Zhang, Y. T.; Zhang, Yu; Zhang, Z. H.; Zhang, Z. P.; Zhang, Z. Y.; Zhao, G.; Zhao, J. W.; Zhao, J. Y.; Zhao, J. Z.; Zhao, Lei; Zhao, Ling; Zhao, M. G.; Zhao, Q.; Zhao, Q. W.; Zhao, S. J.; Zhao, T. C.; Zhao, Y. B.; Zhao, Z. G.; Zhemchugov, A.; Zheng, B.; Zheng, J. P.; Zheng, W. J.; Zheng, Y. H.; Zhong, B.; Zhou, L.; Zhou, X.; Zhou, X. K.; Zhou, X. R.; Zhou, X. Y.; Zhu, K.; Zhu, K. J.; Zhu, S.; Zhu, S. H.; Zhu, X. L.; Zhu, Y. C.; Zhu, Y. S.; Zhu, Z. A.; Zhuangig, J.; Zotti, L.; Zou, B. S.; Zou, J. H.

    2016-01-01

    By analyzing 2.93 fb(-1) data collected at the center-of-mass energy root s = 3.773 GeV with the BESIII detector, we measure the absolute branching fraction of the semileptonic decay D+ -> (K) over bar (0)e(+)nu(e) to be B(D (+) -> (K) over bar (0)e(+)nu(e)) = (8.59 +/- 0.14 +/- 0.21)% using (K)

  10. Homogenised constitutive model dedicated to reinforced concrete plates subjected to seismic solicitations

    International Nuclear Information System (INIS)

    Combescure, Christelle

    2013-01-01

    Safety reassessments are periodically performed on the EDF nuclear power plants and the recent seismic reassessments leaded to the necessity of taking into account the non-linear behaviour of materials when modeling and simulating industrial structures of these power plants under seismic solicitations. A large proportion of these infrastructures is composed of reinforced concrete buildings, including reinforced concrete slabs and walls, and literature seems to be poor on plate modeling dedicated to seismic applications for this material. As for the few existing models dedicated to these specific applications, they present either a lack of dissipation energy in the material behaviour, or no micromechanical approach that justifies the parameters needed to properly describe the model. In order to provide a constitutive model which better represents the reinforced concrete plate behaviour under seismic loadings and whose parameters are easier to identify for the civil engineer, a constitutive model dedicated to reinforced concrete plates under seismic solicitations is proposed: the DHRC (Dissipative Homogenised Reinforced Concrete) model. Justified by a periodic homogenisation approach, this model includes two dissipative phenomena: damage of concrete matrix and internal sliding at the interface between steel rebar and surrounding concrete. An original coupling term between damage and sliding, resulting from the homogenisation process, induces a better representation of energy dissipation during the material degradation. The model parameters are identified from the geometric characteristics of the plate and a restricted number of material characteristics, allowing a very simple use of the model. Numerical validations of the DHRC model are presented, showing good agreement with experimental behaviour. A one dimensional simplification of the DHRC model is proposed, allowing the representation of reinforced concrete bars and simplified models of rods and wire mesh

  11. Measurement of Poisson's ratio of nonmetallic materials by laser holographic interferometry

    Science.gov (United States)

    Zhu, Jian T.

    1991-12-01

    By means of the off-axis collimated plane wave coherent light arrangement and a loading device by pure bending, Poisson's ratio values of CFRP (carbon fiber-reinforced plactics plates, lay-up 0 degree(s), 90 degree(s)), GFRP (glass fiber-reinforced plactics plates, radial direction) and PMMA (polymethyl methacrylate, x, y direction) have been measured. In virtue of this study, the ministry standard for the Ministry of Aeronautical Industry (Testing method for the measurement of Poisson's ratio of non-metallic by laser holographic interferometry) has been published. The measurement process is fast and simple. The measuring results are reliable and accurate.

  12. The carbon fibre market and uses for composite wind blades

    Energy Technology Data Exchange (ETDEWEB)

    Lowe, J R [Tenax Fibers Gmbh and Co. KG, Wuppertal (Germany)

    1996-09-01

    Due to its excellent fatigue properties, low weight and high stiffness, carbon fibre reinforced plastic (CFRP) is the ideal material to use for the manufacture of wind blades. The present use of CFRP in the wind energy sector however is very low in comparison to glass fibre reinforced plastic (GFRP) materials. The main reason for this low use of CFRP is cost since at present times carbon fibre is valued ten times as much as glass fibre. This paper introduces carbon fibre as an alternative material to glass and examines the use of CFRP components in other high fatigue applications. (au)

  13. Bar Coding and Tracking in Pathology.

    Science.gov (United States)

    Hanna, Matthew G; Pantanowitz, Liron

    2016-03-01

    Bar coding and specimen tracking are intricately linked to pathology workflow and efficiency. In the pathology laboratory, bar coding facilitates many laboratory practices, including specimen tracking, automation, and quality management. Data obtained from bar coding can be used to identify, locate, standardize, and audit specimens to achieve maximal laboratory efficiency and patient safety. Variables that need to be considered when implementing and maintaining a bar coding and tracking system include assets to be labeled, bar code symbologies, hardware, software, workflow, and laboratory and information technology infrastructure as well as interoperability with the laboratory information system. This article addresses these issues, primarily focusing on surgical pathology. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Characterization of Bars Induced by Interactions

    Directory of Open Access Journals (Sweden)

    Inma Martinez-Valpuesta

    2016-05-01

    Full Text Available Whether the formation of bars is triggered by interactions or by internal processes has been discussed for many decades. In this work, we study differences between both mechanisms by means of numerical simulations. We relate our analysis to fly-by interactions in different mass groups or clusters according to the velocity of the encounters. We find that once the bar is created, the interaction does not much affect its evolution. We also find that bars can be triggered purely by a slow interaction. Those bars affected or triggered by interaction stay for a longer time in the slow regime, i.e., the corotation radius is more than 1.4 times the bar radius.

  15. Hanging off a bar

    NARCIS (Netherlands)

    Mueller, F.; Walmink, W.; Toprak, C.; Bongers, Bert; Graether, E.; Hoven, van den E.A.W.H.

    2012-01-01

    Exertion Games involve physical effort and as a result can facilitate physical health benefits. We present Hanging off a Bar, an action hero-inspired Exertion Game in which players hang off an exercise bar over a virtual river for as long as possible. Initial observations from three events with

  16. Raising the bar (6)

    NARCIS (Netherlands)

    Elhorst, Paul; Abreu, Maria; Amaral, Pedro; Bhattacharjee, Arnab; Corrado, Luisa; Doran, Justin; Fingleton, Bernard; Fuerst, Franz; Garretsen, Harry; Igliori, Danilo; Le Gallo, Julie; McCann, Philip; Monastiriotis, Vassilis; Quatraro, Francesco; Yu, Jihai

    2017-01-01

    Raising the bar (6). Spatial Economic Analysis. This editorial summarizes and comments on the papers published in issue 12(4) so as to raise the bar in applied spatial economic research and highlight new trends. The first paper addresses the question of whether 'jobs follow people' or 'people follow

  17. Why Are Some Galaxies Not Barred?

    Science.gov (United States)

    Saha, Kanak; Elmegreen, Bruce

    2018-05-01

    Although more than two-thirds of star-forming disk galaxies in the local universe are barred, some galaxies remain unbarred, occupying the upper half of the Hubble tuning fork diagram. Numerical simulations almost always produce bars spontaneously, so it remains a challenge to understand how galaxies sometimes prevent bars from forming. Using a set of collisionless simulations, we first reproduce the common result that cold stellar disks surrounding a classical bulge become strongly unstable to non-axisymmetric perturbations, leading to the rapid formation of spiral structure and bars. However, our analyses show that galaxy models with compact classical bulges (whose average density is greater than or comparable to the disk density calculated within bulge half-mass radii) are able to prevent bar formation for at least 4 Gyr even when the stellar disk is maximal and having low Toomre Q. Such bar prevention is the result of several factors such as (a) a small inner Lindblad resonance with a high angular rate, which contaminates an incipient bar with x 2 orbits, and (b) rapid loss of angular momentum accompanied by a rapid heating in the center from initially strong bar and spiral instabilities in a low-Q disk; in other words, a rapid initial rise to a value larger than ∼5 of the ratio of the random energy to the rotational energy in the central region of the galaxy.

  18. Preparation of a Breadfruit Flour Bar.

    Science.gov (United States)

    Nochera, Carmen L; Ragone, Diane

    2016-05-20

    Breadfruit is a nutritious, high energy food with a low quantity of protein but excellent protein quality. It has the potential to be developed into desired products which will help increase its utilization and add value to the crop. The overall purposes of this investigation were to develop a portable, nutritious, ready-to-eat breadfruit product (bar), test the sensory qualities of the product, and evaluate the nutritional properties of the product. Flour made from the Micronesian variety, Meinpadahk ( Artocarpus altilis × Artocarpus mariannensis ), was utilized for the development of the breadfruit bar. Breadfruit is a rich source of fiber, vitamins such as vitamin C, minerals such as potassium, and phytochemicals such as flavonoids. Nutritional labeling indicates that the breadfruit bar is high in carbohydrates and low in fat, and sensory evaluation indicates that 81% of the panelists found the bar acceptable while 19% disliked the bar. The breadfruit bar can provide an appealing and inexpensive gluten-free food source based on locally available breadfruit.

  19. Braided reinforced composite rods for the internal reinforcement of concrete

    Science.gov (United States)

    Gonilho Pereira, C.; Fangueiro, R.; Jalali, S.; Araujo, M.; Marques, P.

    2008-05-01

    This paper reports on the development of braided reinforced composite rods as a substitute for the steel reinforcement in concrete. The research work aims at understanding the mechanical behaviour of core-reinforced braided fabrics and braided reinforced composite rods, namely concerning the influence of the braiding angle, the type of core reinforcement fibre, and preloading and postloading conditions. The core-reinforced braided fabrics were made from polyester fibres for producing braided structures, and E-glass, carbon, HT polyethylene, and sisal fibres were used for the core reinforcement. The braided reinforced composite rods were obtained by impregnating the core-reinforced braided fabric with a vinyl ester resin. The preloading of the core-reinforced braided fabrics and the postloading of the braided reinforced composite rods were performed in three and two stages, respectively. The results of tensile tests carried out on different samples of core-reinforced braided fabrics are presented and discussed. The tensile and bending properties of the braided reinforced composite rods have been evaluated, and the results obtained are presented, discussed, and compared with those of conventional materials, such as steel.

  20. 21 CFR 886.1650 - Ophthalmic bar prism.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic bar prism. 886.1650 Section 886.1650...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1650 Ophthalmic bar prism. (a) Identification. An ophthalmic bar prism is a device that is a bar composed of fused prisms of gradually increasing...