  1. Characterization, prediction, and correction of geometric distortion in 3 T MR images

    International Nuclear Information System (INIS)

    Baldwin, Lesley N.; Wachowicz, Keith; Thomas, Steven D.; Rivest, Ryan; Gino Fallone, B.

    2007-01-01

    The work presented herein describes our methods and results for predicting, measuring and correcting geometric distortions in a 3 T clinical magnetic resonance (MR) scanner for the purpose of image guidance in radiation treatment planning. Geometric inaccuracies due to both inhomogeneities in the background field and nonlinearities in the applied gradients were easily visualized on the MR images of a regularly structured three-dimensional (3D) grid phantom. From a computed tomography scan, the locations of just under 10 000 control points within the phantom were accurately determined in three dimensions using a MATLAB-based computer program. MR distortion was then determined by measuring the corresponding locations of the control points when the phantom was imaged using the MR scanner. Using a reversed gradient method, distortions due to gradient nonlinearities were separated from distortions due to inhomogeneities in the background B 0 field. Because the various sources of machine-related distortions can be individually characterized, distortions present in other imaging sequences (for which 3D distortion cannot accurately be measured using phantom methods) can be predicted negating the need for individual distortion calculation for a variety of other imaging sequences. Distortions were found to be primarily caused by gradient nonlinearities and maximum image distortions were reported to be less than those previously found by other researchers at 1.5 T. Finally, the image slices were corrected for distortion in order to provide geometrically accurate phantom images

  2. Real-Time Correction By Optical Tracking with Integrated Geometric Distortion Correction for Reducing Motion Artifacts in fMRI

    Science.gov (United States)

    Rotenberg, David J.

    Artifacts caused by head motion are a substantial source of error in fMRI that limits its use in neuroscience research and clinical settings. Real-time scan-plane correction by optical tracking has been shown to correct slice misalignment and non-linear spin-history artifacts, however residual artifacts due to dynamic magnetic field non-uniformity may remain in the data. A recently developed correction technique, PLACE, can correct for absolute geometric distortion using the complex image data from two EPI images, with slightly shifted k-space trajectories. We present a correction approach that integrates PLACE into a real-time scan-plane update system by optical tracking, applied to a tissue-equivalent phantom undergoing complex motion and an fMRI finger tapping experiment with overt head motion to induce dynamic field non-uniformity. Experiments suggest that including volume by volume geometric distortion correction by PLACE can suppress dynamic geometric distortion artifacts in a phantom and in vivo and provide more robust activation maps.

  3. Correcting geometric and photometric distortion of document images on a smartphone

    Science.gov (United States)

    Simon, Christian; Williem; Park, In Kyu

    2015-01-01

    A set of document image processing algorithms for improving the optical character recognition (OCR) capability of smartphone applications is presented. The scope of the problem covers the geometric and photometric distortion correction of document images. The proposed framework was developed to satisfy industrial requirements. It is implemented on an off-the-shelf smartphone with limited resources in terms of speed and memory. Geometric distortions, i.e., skew and perspective distortion, are corrected by sending horizontal and vertical vanishing points toward infinity in a downsampled image. Photometric distortion includes image degradation from moiré pattern noise and specular highlights. Moiré pattern noise is removed using low-pass filters with different sizes independently applied to the background and text region. The contrast of the text in a specular highlighted area is enhanced by locally enlarging the intensity difference between the background and text while the noise is suppressed. Intensive experiments indicate that the proposed methods show a consistent and robust performance on a smartphone with a runtime of less than 1 s.

  4. Correction of MRI-induced geometric distortions in whole-body small animal PET-MRI

    International Nuclear Information System (INIS)

    Frohwein, Lynn J.; Schäfers, Klaus P.; Hoerr, Verena; Faber, Cornelius

    2015-01-01

    Purpose: The fusion of positron emission tomography (PET) and magnetic resonance imaging (MRI) data can be a challenging task in whole-body PET-MRI. The quality of the registration between these two modalities in large field-of-views (FOV) is often degraded by geometric distortions of the MRI data. The distortions at the edges of large FOVs mainly originate from MRI gradient nonlinearities. This work describes a method to measure and correct for these kind of geometric distortions in small animal MRI scanners to improve the registration accuracy of PET and MRI data. Methods: The authors have developed a geometric phantom which allows the measurement of geometric distortions in all spatial axes via control points. These control points are detected semiautomatically in both PET and MRI data with a subpixel accuracy. The spatial transformation between PET and MRI data is determined with these control points via 3D thin-plate splines (3D TPS). The transformation derived from the 3D TPS is finally applied to real MRI mouse data, which were acquired with the same scan parameters used in the phantom data acquisitions. Additionally, the influence of the phantom material on the homogeneity of the magnetic field is determined via field mapping. Results: The spatial shift according to the magnetic field homogeneity caused by the phantom material was determined to a mean of 0.1 mm. The results of the correction show that distortion with a maximum error of 4 mm could be reduced to less than 1 mm with the proposed correction method. Furthermore, the control point-based registration of PET and MRI data showed improved congruence after correction. Conclusions: The developed phantom has been shown to have no considerable negative effect on the homogeneity of the magnetic field. The proposed method yields an appropriate correction of the measured MRI distortion and is able to improve the PET and MRI registration. Furthermore, the method is applicable to whole-body small animal

  5. Correction of MRI-induced geometric distortions in whole-body small animal PET-MRI

    Energy Technology Data Exchange (ETDEWEB)

    Frohwein, Lynn J., E-mail: frohwein@uni-muenster.de; Schäfers, Klaus P. [European Institute for Molecular Imaging, University of Münster, Münster 48149 (Germany); Hoerr, Verena; Faber, Cornelius [Department of Clinical Radiology, University Hospital of Münster, Münster 48149 (Germany)

    2015-07-15

    Purpose: The fusion of positron emission tomography (PET) and magnetic resonance imaging (MRI) data can be a challenging task in whole-body PET-MRI. The quality of the registration between these two modalities in large field-of-views (FOV) is often degraded by geometric distortions of the MRI data. The distortions at the edges of large FOVs mainly originate from MRI gradient nonlinearities. This work describes a method to measure and correct for these kind of geometric distortions in small animal MRI scanners to improve the registration accuracy of PET and MRI data. Methods: The authors have developed a geometric phantom which allows the measurement of geometric distortions in all spatial axes via control points. These control points are detected semiautomatically in both PET and MRI data with a subpixel accuracy. The spatial transformation between PET and MRI data is determined with these control points via 3D thin-plate splines (3D TPS). The transformation derived from the 3D TPS is finally applied to real MRI mouse data, which were acquired with the same scan parameters used in the phantom data acquisitions. Additionally, the influence of the phantom material on the homogeneity of the magnetic field is determined via field mapping. Results: The spatial shift according to the magnetic field homogeneity caused by the phantom material was determined to a mean of 0.1 mm. The results of the correction show that distortion with a maximum error of 4 mm could be reduced to less than 1 mm with the proposed correction method. Furthermore, the control point-based registration of PET and MRI data showed improved congruence after correction. Conclusions: The developed phantom has been shown to have no considerable negative effect on the homogeneity of the magnetic field. The proposed method yields an appropriate correction of the measured MRI distortion and is able to improve the PET and MRI registration. Furthermore, the method is applicable to whole-body small animal

  6. Concurrent correction of geometric distortion and motion using the map-slice-to-volume method in EPI

    Science.gov (United States)

    Yeo, Desmond T. B.; Fessler, Jeffrey A.; Kim, Boklye

    2014-01-01

    The accuracy of measuring voxel intensity changes between stimulus and rest images in fMRI echo-planar imaging (EPI) data is severely degraded in the presence of head motion. In addition, EPI is sensitive to susceptibility-induced geometric distortions. Head motion causes image shifts and associated field map changes that induce different geometric distortion at different time points. Conventionally, geometric distortion is “corrected” with a static field map independently of image registration. That approach ignores all field map changes induced by head motion. This work evaluates the improved motion correction capability of mapping slice to volume (MSV) registration with concurrent iterative field corrected reconstruction using updated field maps derived from an initial static field map that has been spatially transformed and resampled. It accounts for motion-induced field map changes for translational and in-plane rotation motion. The results from simulated EPI time series data, in which motion, image intensity and activation ground truths are available, show improved accuracy in image registration, field corrected image reconstruction and activation detection. PMID:18280077

  7. Concurrent correction of geometric distortion and motion using the map-slice-to-volume method in echo-planar imaging.

    Science.gov (United States)

    Yeo, Desmond T B; Fessler, Jeffrey A; Kim, Boklye

    2008-06-01

    The accuracy of measuring voxel intensity changes between stimulus and rest images in fMRI echo-planar imaging (EPI) data is severely degraded in the presence of head motion. In addition, EPI is sensitive to susceptibility-induced geometric distortions. Head motion causes image shifts and associated field map changes that induce different geometric distortion at different time points. Conventionally, geometric distortion is "corrected" with a static field map independently of image registration. That approach ignores all field map changes induced by head motion. This work evaluates the improved motion correction capability of mapping slice to volume with concurrent iterative field corrected reconstruction using updated field maps derived from an initial static field map that has been spatially transformed and resampled. It accounts for motion-induced field map changes for translational and in-plane rotation motion. The results from simulated EPI time series data, in which motion, image intensity and activation ground truths are available, show improved accuracy in image registration, field corrected image reconstruction and activation detection.

  8. Review and comparison of geometric distortion correction schemes in MR images used in stereotactic radiosurgery applications

    Science.gov (United States)

    Pappas, E. P.; Dellios, D.; Seimenis, I.; Moutsatsos, A.; Georgiou, E.; Karaiskos, P.

    2017-11-01

    In Stereotactic Radiosurgery (SRS), MR-images are widely used for target localization and delineation in order to take advantage of the superior soft tissue contrast they exhibit. However, spatial dose delivery accuracy may be deteriorated due to geometric distortions which are partly attributed to static magnetic field inhomogeneity and patient/object-induced chemical shift and susceptibility related artifacts, known as sequence-dependent distortions. Several post-imaging sequence-dependent distortion correction schemes have been proposed which mainly employ the reversal of read gradient polarity. The scope of this work is to review, evaluate and compare the efficacy of two proposed correction approaches. A specially designed phantom which incorporates 947 control points (CPs) for distortion detection was utilized. The phantom was MR scanned at 1.5T using the head coil and the clinically employed pulse sequence for SRS treatment planning. An additional scan was performed with identical imaging parameters except for reversal of read gradient polarity. In-house MATLAB routines were developed for implementation of the signal integration and average-image distortion correction techniques. The mean CP locations of the two MR scans were regarded as the reference CP distribution. Residual distortion was assessed by comparing the corrected CP locations with corresponding reference positions. Mean absolute distortion on frequency encoding direction was reduced from 0.34mm (original images) to 0.15mm and 0.14mm following application of signal integration and average-image methods, respectively. However, a maximum residual distortion of 0.7mm was still observed for both techniques. The signal integration method relies on the accuracy of edge detection and requires 3-4 hours of post-imaging computational time. The average-image technique is a more efficient (processing time of the order of seconds) and easier to implement method to improve geometric accuracy in such

  9. Quality Evaluation and Nonuniform Compression of Geometrically Distorted Images Using the Quadtree Distortion Map

    Directory of Open Access Journals (Sweden)

    Cristina Costa

    2004-09-01

    Full Text Available The paper presents an analysis of the effects of lossy compression algorithms applied to images affected by geometrical distortion. It will be shown that the encoding-decoding process results in a nonhomogeneous image degradation in the geometrically corrected image, due to the different amount of information associated to each pixel. A distortion measure named quadtree distortion map (QDM able to quantify this aspect is proposed. Furthermore, QDM is exploited to achieve adaptive compression of geometrically distorted pictures, in order to ensure a uniform quality on the final image. Tests are performed using JPEG and JPEG2000 coding standards in order to quantitatively and qualitatively assess the performance of the proposed method.

  10. Spatial Precision in Magnetic Resonance Imaging–Guided Radiation Therapy: The Role of Geometric Distortion

    Energy Technology Data Exchange (ETDEWEB)

    Weygand, Joseph, E-mail: jw2899@columbia.edu [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, Texas (United States); Fuller, Clifton David [The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, Texas (United States); Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Ibbott, Geoffrey S. [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, Texas (United States); Mohamed, Abdallah S.R. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Department of Clinical Oncology and Nuclear Medicine, Alexandria University, Alexandria (Egypt); Ding, Yao [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Yang, Jinzhong [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, Texas (United States); Hwang, Ken-Pin [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Wang, Jihong [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, Texas (United States)

    2016-07-15

    Because magnetic resonance imaging–guided radiation therapy (MRIgRT) offers exquisite soft tissue contrast and the ability to image tissues in arbitrary planes, the interest in this technology has increased dramatically in recent years. However, intrinsic geometric distortion stemming from both the system hardware and the magnetic properties of the patient affects MR images and compromises the spatial integrity of MRI-based radiation treatment planning, given that for real-time MRIgRT, precision within 2 mm is desired. In this article, we discuss the causes of geometric distortion, describe some well-known distortion correction algorithms, and review geometric distortion measurements from 12 studies, while taking into account relevant imaging parameters. Eleven of the studies reported phantom measurements quantifying system-dependent geometric distortion, while 2 studies reported simulation data quantifying magnetic susceptibility–induced geometric distortion. Of the 11 studies investigating system-dependent geometric distortion, 5 reported maximum measurements less than 2 mm. The simulation studies demonstrated that magnetic susceptibility–induced distortion is typically smaller than system-dependent distortion but still nonnegligible, with maximum distortion ranging from 2.1 to 2.6 mm at a field strength of 1.5 T. As expected, anatomic landmarks containing interfaces between air and soft tissue had the largest distortions. The evidence indicates that geometric distortion reduces the spatial integrity of MRI-based radiation treatment planning and likely diminishes the efficacy of MRIgRT. Better phantom measurement techniques and more effective distortion correction algorithms are needed to achieve the desired spatial precision.

  11. Spatial Precision in Magnetic Resonance Imaging–Guided Radiation Therapy: The Role of Geometric Distortion

    International Nuclear Information System (INIS)

    Weygand, Joseph; Fuller, Clifton David; Ibbott, Geoffrey S.; Mohamed, Abdallah S.R.; Ding, Yao; Yang, Jinzhong; Hwang, Ken-Pin; Wang, Jihong

    2016-01-01

    Because magnetic resonance imaging–guided radiation therapy (MRIgRT) offers exquisite soft tissue contrast and the ability to image tissues in arbitrary planes, the interest in this technology has increased dramatically in recent years. However, intrinsic geometric distortion stemming from both the system hardware and the magnetic properties of the patient affects MR images and compromises the spatial integrity of MRI-based radiation treatment planning, given that for real-time MRIgRT, precision within 2 mm is desired. In this article, we discuss the causes of geometric distortion, describe some well-known distortion correction algorithms, and review geometric distortion measurements from 12 studies, while taking into account relevant imaging parameters. Eleven of the studies reported phantom measurements quantifying system-dependent geometric distortion, while 2 studies reported simulation data quantifying magnetic susceptibility–induced geometric distortion. Of the 11 studies investigating system-dependent geometric distortion, 5 reported maximum measurements less than 2 mm. The simulation studies demonstrated that magnetic susceptibility–induced distortion is typically smaller than system-dependent distortion but still nonnegligible, with maximum distortion ranging from 2.1 to 2.6 mm at a field strength of 1.5 T. As expected, anatomic landmarks containing interfaces between air and soft tissue had the largest distortions. The evidence indicates that geometric distortion reduces the spatial integrity of MRI-based radiation treatment planning and likely diminishes the efficacy of MRIgRT. Better phantom measurement techniques and more effective distortion correction algorithms are needed to achieve the desired spatial precision.

  12. Harmonic analysis for the characterization and correction of geometric distortion in MRI.

    Science.gov (United States)

    Tadic, Tony; Jaffray, David A; Stanescu, Teodor

    2014-11-01

    Magnetic resonance imaging (MRI) is gaining widespread use in radiation therapy planning, patient setup verification, and real-time guidance of radiation delivery. Successful implementation of these technologies relies on the development of simple and efficient methods to characterize and monitor the geometric distortions arising due to system imperfections and gradient nonlinearities. To this end, the authors present the theory and validation of a novel harmonic approach to the quantification of system-related distortions in MRI. The theory of spatial encoding in MRI is applied to demonstrate that the 3D distortion vector field (DVF) is given by the solution of a second-order boundary value problem (BVP). This BVP is comprised of Laplace's equation and a limited measurement of the distortion on the boundary of a specified region of interest (ROI). An analytical series expansion solving this BVP within a spherical ROI is obtained, and a statistical uncertainty analysis is performed to determine how random errors in the boundary measurements propagate to the ROI interior. This series expansion is then evaluated to obtain volumetric DVF mappings that are compared to reference data obtained on a 3 T full-body scanner. This validation is performed within two spheres of 20 cm diameter (one centered at the scanner origin and the other offset +3 cm along each of the transverse directions). Initially, a high-order mapping requiring measurements at 5810 boundary points is used. Then, after exploring the impact of the boundary sampling density and the effect of series truncation, a reduced-order mapping requiring measurements at 302 boundary points is evaluated. The volumetric DVF mappings obtained from the harmonic analysis are in good agreement with the reference data. Following distortion correction using the high-order mapping, the authors estimate a reduction in the mean distortion magnitude from 0.86 to 0.42 mm and from 0.93 to 0.39 mm within the central and offset

  13. Harmonic analysis for the characterization and correction of geometric distortion in MRI

    International Nuclear Information System (INIS)

    Tadic, Tony; Stanescu, Teodor; Jaffray, David A.

    2014-01-01

    Purpose: Magnetic resonance imaging (MRI) is gaining widespread use in radiation therapy planning, patient setup verification, and real-time guidance of radiation delivery. Successful implementation of these technologies relies on the development of simple and efficient methods to characterize and monitor the geometric distortions arising due to system imperfections and gradient nonlinearities. To this end, the authors present the theory and validation of a novel harmonic approach to the quantification of system-related distortions in MRI. Methods: The theory of spatial encoding in MRI is applied to demonstrate that the 3D distortion vector field (DVF) is given by the solution of a second-order boundary value problem (BVP). This BVP is comprised of Laplace’s equation and a limited measurement of the distortion on the boundary of a specified region of interest (ROI). An analytical series expansion solving this BVP within a spherical ROI is obtained, and a statistical uncertainty analysis is performed to determine how random errors in the boundary measurements propagate to the ROI interior. This series expansion is then evaluated to obtain volumetric DVF mappings that are compared to reference data obtained on a 3 T full-body scanner. This validation is performed within two spheres of 20 cm diameter (one centered at the scanner origin and the other offset +3 cm along each of the transverse directions). Initially, a high-order mapping requiring measurements at 5810 boundary points is used. Then, after exploring the impact of the boundary sampling density and the effect of series truncation, a reduced-order mapping requiring measurements at 302 boundary points is evaluated. Results: The volumetric DVF mappings obtained from the harmonic analysis are in good agreement with the reference data. Following distortion correction using the high-order mapping, the authors estimate a reduction in the mean distortion magnitude from 0.86 to 0.42 mm and from 0.93 to 0.39 mm

  14. Flat-field response and geometric distortion measurements of optical streak cameras

    International Nuclear Information System (INIS)

    Montgomery, D.S.; Drake, R.P.; Jones, B.A.; Wiedwald, J.D.

    1987-08-01

    To accurately measure pulse amplitude, shape, and relative time histories of optical signals with an optical streak camera, it is necessary to correct each recorded image for spatially-dependent gain nonuniformity and geometric distortion. Gain nonuniformities arise from sensitivity variations in the streak-tube photocathode, phosphor screen, image-intensifier tube, and image recording system. These nonuniformities may be severe, and have been observed to be on the order of 100% for some LLNL optical streak cameras. Geometric distortion due to optical couplings, electron-optics, and sweep nonlinearity not only affects pulse position and timing measurements, but affects pulse amplitude and shape measurements as well. By using a 1.053-μm, long-pulse, high-power laser to generate a spatially and temporally uniform source as input to the streak camera, the combined effects of flat-field response and geometric distortion can be measured under the normal dynamic operation of cameras with S-1 photocathodes. Additionally, by using the same laser system to generate a train of short pulses that can be spatially modulated at the input of the streak camera, we can effectively create a two-dimensional grid of equally-spaced pulses. This allows a dynamic measurement of the geometric distortion of the streak camera. We will discuss the techniques involved in performing these calibrations, will present some of the measured results for LLNL optical streak cameras, and will discuss software methods to correct for these effects. 6 refs., 6 figs

  15. Flat-field response and geometric distortion measurements of optical streak cameras

    International Nuclear Information System (INIS)

    Montgomery, D.S.; Drake, R.P.; Jones, B.A.; Wiedwald, J.D.

    1987-01-01

    To accurately measure pulse amplitude, shape, and relative time histories of optical signals with an optical streak camera, it is necessary to correct each recorded image for spatially-dependent gain nonuniformity and geometric distortion. Gain nonuniformities arise from sensitivity variations in the streak-tube photocathode, phosphor screen, image-intensifier tube, and image recording system. By using a 1.053-μm, long-pulse, high-power laser to generate a spatially and temporally uniform source as input to the streak camera, the combined effects of flat-field response and geometric distortion can be measured under the normal dynamic operation of cameras with S-1 photocathodes. Additionally, by using the same laser system to generate a train of short pulses that can be spatially modulated at the input of the streak camera, the authors can create a two-dimensional grid of equally-spaced pulses. This allows a dynamic measurement of the geometric distortion of the streak camera. The author discusses the techniques involved in performing these calibrations, present some of the measured results for LLNL optical streak cameras, and will discuss software methods to correct for these effects

  16. Mobile Watermarking against Geometrical Distortions

    Directory of Open Access Journals (Sweden)

    Jing Zhang

    2015-08-01

    Full Text Available Mobile watermarking robust to geometrical distortions is still a great challenge. In mobile watermarking, efficient computation is necessary because mobile devices have very limited resources due to power consumption. In this paper, we propose a low-complexity geometrically resilient watermarking approach based on the optimal tradeoff circular harmonic function (OTCHF correlation filter and the minimum average correlation energy Mellin radial harmonic (MACE-MRH correlation filter. By the rotation, translation and scale tolerance properties of the two kinds of filter, the proposed watermark detector can be robust to geometrical attacks. The embedded watermark is weighted by a perceptual mask which matches very well with the properties of the human visual system. Before correlation, a whitening process is utilized to improve watermark detection reliability. Experimental results demonstrate that the proposed watermarking approach is computationally efficient and robust to geometrical distortions.

  17. Improved volumetric measurement of brain structure with a distortion correction procedure using an ADNI phantom.

    Science.gov (United States)

    Maikusa, Norihide; Yamashita, Fumio; Tanaka, Kenichiro; Abe, Osamu; Kawaguchi, Atsushi; Kabasawa, Hiroyuki; Chiba, Shoma; Kasahara, Akihiro; Kobayashi, Nobuhisa; Yuasa, Tetsuya; Sato, Noriko; Matsuda, Hiroshi; Iwatsubo, Takeshi

    2013-06-01

    Serial magnetic resonance imaging (MRI) images acquired from multisite and multivendor MRI scanners are widely used in measuring longitudinal structural changes in the brain. Precise and accurate measurements are important in understanding the natural progression of neurodegenerative disorders such as Alzheimer's disease. However, geometric distortions in MRI images decrease the accuracy and precision of volumetric or morphometric measurements. To solve this problem, the authors suggest a commercially available phantom-based distortion correction method that accommodates the variation in geometric distortion within MRI images obtained with multivendor MRI scanners. The authors' method is based on image warping using a polynomial function. The method detects fiducial points within a phantom image using phantom analysis software developed by the Mayo Clinic and calculates warping functions for distortion correction. To quantify the effectiveness of the authors' method, the authors corrected phantom images obtained from multivendor MRI scanners and calculated the root-mean-square (RMS) of fiducial errors and the circularity ratio as evaluation values. The authors also compared the performance of the authors' method with that of a distortion correction method based on a spherical harmonics description of the generic gradient design parameters. Moreover, the authors evaluated whether this correction improves the test-retest reproducibility of voxel-based morphometry in human studies. A Wilcoxon signed-rank test with uncorrected and corrected images was performed. The root-mean-square errors and circularity ratios for all slices significantly improved (p Wilcoxon signed-rank test, p test-retest reproducibility. The results showed that distortion was corrected significantly using the authors' method. In human studies, the reproducibility of voxel-based morphometry analysis for the whole gray matter significantly improved after distortion correction using the authors

  18. New Geometric-distortion Solution for STIS FUV-MAMA

    Science.gov (United States)

    Sohn, S. Tony

    2018-04-01

    We derived a new geometric distortion solution for the STIS FUV-MAMA detector. To do this, positions of stars in 89 FUV-MAMA observations of NGC 6681 were compared to an astrometric standard catalog created using WFC3/UVIS imaging data to derive a fourth-order polynomial solution that transforms raw (x, y) positions to geometrically- corrected (x, y) positions. When compared to astrometric catalog positions, the FUV- MAMA position measurements based on the IDCTAB showed residuals with an RMS of ∼ 30 mas in each coordinate. Using the new IDCTAB, the RMS is reduced to ∼ 4 mas, or 0.16 FUV-MAMA pixels, in each coordinate. The updated IDCTAB is now being used in the HST STIS pipeline to process all STIS FUV-MAMA images.

  19. Distortion Correction in Fetal EPI Using Non-Rigid Registration With a Laplacian Constraint.

    Science.gov (United States)

    Kuklisova-Murgasova, Maria; Lockwood Estrin, Georgia; Nunes, Rita G; Malik, Shaihan J; Rutherford, Mary A; Rueckert, Daniel; Hajnal, Joseph V

    2018-01-01

    Geometric distortion induced by the main B0 field disrupts the consistency of fetal echo planar imaging (EPI) data, on which diffusion and functional magnetic resonance imaging is based. In this paper, we present a novel data-driven method for simultaneous motion and distortion correction of fetal EPI. A motion-corrected and reconstructed T2 weighted single shot fast spin echo (ssFSE) volume is used as a model of undistorted fetal brain anatomy. Our algorithm interleaves two registration steps: estimation of fetal motion parameters by aligning EPI slices to the model; and deformable registration of EPI slices to slices simulated from the undistorted model to estimate the distortion field. The deformable registration is regularized by a physically inspired Laplacian constraint, to model distortion induced by a source-free background B0 field. Our experiments show that distortion correction significantly improves consistency of reconstructed EPI volumes with ssFSE volumes. In addition, the estimated distortion fields are consistent with fields calculated from acquired field maps, and the Laplacian constraint is essential for estimation of plausible distortion fields. The EPI volumes reconstructed from different scans of the same subject were more consistent when the proposed method was used in comparison with EPI volumes reconstructed from data distortion corrected using a separately acquired B0 field map.

  20. Geometric correction of APEX hyperspectral data

    Directory of Open Access Journals (Sweden)

    Vreys Kristin

    2016-03-01

    Full Text Available Hyperspectral imagery originating from airborne sensors is nowadays widely used for the detailed characterization of land surface. The correct mapping of the pixel positions to ground locations largely contributes to the success of the applications. Accurate geometric correction, also referred to as “orthorectification”, is thus an important prerequisite which must be performed prior to using airborne imagery for evaluations like change detection, or mapping or overlaying the imagery with existing data sets or maps. A so-called “ortho-image” provides an accurate representation of the earth’s surface, having been adjusted for lens distortions, camera tilt and topographic relief. In this paper, we describe the different steps in the geometric correction process of APEX hyperspectral data, as applied in the Central Data Processing Center (CDPC at the Flemish Institute for Technological Research (VITO, Mol, Belgium. APEX ortho-images are generated through direct georeferencing of the raw images, thereby making use of sensor interior and exterior orientation data, boresight calibration data and elevation data. They can be referenced to any userspecified output projection system and can be resampled to any output pixel size.

  1. A high precision recipe for correcting images distorted by a tapered fiber optic

    International Nuclear Information System (INIS)

    Islam, M Sirajul; Kitchen, M J; Lewis, R A; Uesugi, K

    2010-01-01

    Images captured with a tapered fiber optic camera show significant spatial distortion mainly because the spatial orientation of the fiber bundles is not identical at each end of the taper. We present three different techniques for the automatic distortion correction of images acquired with a charge-coupled device (CCD) camera bonded to a tapered optical fiber. In this paper we report - (i) comparison of various methods for distortion correction (ii) extensive quantitative analysis of the techniques and (iii) experiments carried out using a high resolution fiber optic camera. A pinhole array was used to find control points in the distorted image space. These control points were then associated with their known true coordinates. To apply geometric correction, three different approaches were investigated - global polynomial fitting, local polynomial fitting and triangulated interpolation. Sub-pixel accuracy was achieved in all approaches, but the experimental results reveal that the triangulated interpolation gave the most satisfactory result for the distortion correction. The effect of proper alignment of the mask with the fiber optic taper (FOT) camera was also investigated. It was found that the overall dewarping error is minimal when the mask is almost parallel to the CCD.

  2. Implementation and Application of PSF-Based EPI Distortion Correction to High Field Animal Imaging

    Directory of Open Access Journals (Sweden)

    Dominik Paul

    2009-01-01

    Full Text Available The purpose of this work is to demonstrate the functionality and performance of a PSF-based geometric distortion correction for high-field functional animal EPI. The EPI method was extended to measure the PSF and a postprocessing chain was implemented in Matlab for offline distortion correction. The correction procedure was applied to phantom and in vivo imaging of mice and rats at 9.4T using different SE-EPI and DWI-EPI protocols. Results show the significant improvement in image quality for single- and multishot EPI. Using a reduced FOV in the PSF encoding direction clearly reduced the acquisition time for PSF data by an acceleration factor of 2 or 4, without affecting the correction quality.

  3. Geometrical theory of nonlinear phase distortion of intense laser beams

    International Nuclear Information System (INIS)

    Glaze, J.A.; Hunt, J.T.; Speck, D.R.

    1975-01-01

    Phase distortion arising from whole beam self-focusing of intense laser pulses with arbitrary spatial profiles is treated in the limit of geometrical optics. The constant shape approximation is used to obtain the phase and angular distribution of the geometrical rays in the near field. Conditions for the validity of this approximation are discussed. Geometrical focusing of the aberrated beam is treated for the special case of a beam with axial symmetry. Equations are derived that show both the shift of the focus and the distortion of the intensity distribution that are caused by the nonlinear index of refraction of the optical medium. An illustrative example treats the case of beam distortion in a Nd:Glass amplifier

  4. Distortion correction algorithm for UAV remote sensing image based on CUDA

    International Nuclear Information System (INIS)

    Wenhao, Zhang; Yingcheng, Li; Delong, Li; Changsheng, Teng; Jin, Liu

    2014-01-01

    In China, natural disasters are characterized by wide distribution, severe destruction and high impact range, and they cause significant property damage and casualties every year. Following a disaster, timely and accurate acquisition of geospatial information can provide an important basis for disaster assessment, emergency relief, and reconstruction. In recent years, Unmanned Aerial Vehicle (UAV) remote sensing systems have played an important role in major natural disasters, with UAVs becoming an important technique of obtaining disaster information. UAV is equipped with a non-metric digital camera with lens distortion, resulting in larger geometric deformation for acquired images, and affecting the accuracy of subsequent processing. The slow speed of the traditional CPU-based distortion correction algorithm cannot meet the requirements of disaster emergencies. Therefore, we propose a Compute Unified Device Architecture (CUDA)-based image distortion correction algorithm for UAV remote sensing, which takes advantage of the powerful parallel processing capability of the GPU, greatly improving the efficiency of distortion correction. Our experiments show that, compared with traditional CPU algorithms and regardless of image loading and saving times, the maximum acceleration ratio using our proposed algorithm reaches 58 times that using the traditional algorithm. Thus, data processing time can be reduced by one to two hours, thereby considerably improving disaster emergency response capability

  5. Investigation of the Geometrical Distortions in the Nuclear Emulsion

    International Nuclear Information System (INIS)

    Batusov, Yu.A.; Rumyantseva, V.P.; Soroko, L.M.; Tereshchenko, V.V.

    1994-01-01

    The geometrical distortions in the nuclear emulsion were investigated by means of two devices: 1) stereoscopic meso-optical Fourier transform microscope (MFTM) and 2) traditional optical microscope (KSM-1) designed for precise measurements. The particle tracks were produced by primary Oxygen-nuclei with impulse 65.6 GeV/c and by secondary α-particles in various regions of the nuclear emulsion. The measurement errors were: 1.8' (angular minute) for orientation angle θ xy ; 2.7' (angular minute) for dip angle θ z ; 0.3 μm for transverse coordinate x; 0.1 μm for longitudinal coordinate y and 0.3 μm for depth coordinate z. The effect of the global forced bending of the nuclear emulsion glass support was detected and estimated as dθ z /dy=2' (angular minute) per mm. To suppress the local geometrical distortions, a difference plot was calculated for two secondary α-particles going very close within ≤ 10 μm over the distance 6 mm. It was shown that this mode of the local geometrical distortions is kept constant over the mutual transverse distances up to 0.6 mm. By observing the zy-plots of four secondary α-particles we have isolated the rotating mode of the local geometrical distortions in the nuclear emulsion. 5 refs., 11 figs

  6. A content-based digital image watermarking scheme resistant to local geometric distortions

    International Nuclear Information System (INIS)

    Yang, Hong-ying; Chen, Li-li; Wang, Xiang-yang

    2011-01-01

    Geometric distortion is known as one of the most difficult attacks to resist, as it can desynchronize the location of the watermark and hence cause incorrect watermark detection. Geometric distortion can be decomposed into two classes: global affine transforms and local geometric distortions. Most countermeasures proposed in the literature only address the problem of global affine transforms. It is a challenging problem to design a robust image watermarking scheme against local geometric distortions. In this paper, we propose a new content-based digital image watermarking scheme with good visual quality and reasonable resistance against local geometric distortions. Firstly, the robust feature points, which can survive various common image processing and global affine transforms, are extracted by using a multi-scale SIFT (scale invariant feature transform) detector. Then, the affine covariant local feature regions (LFRs) are constructed adaptively according to the feature scale and local invariant centroid. Finally, the digital watermark is embedded into the affine covariant LFRs by modulating the magnitudes of discrete Fourier transform (DFT) coefficients. By binding the watermark with the affine covariant LFRs, the watermark detection can be done without synchronization error. Experimental results show that the proposed image watermarking is not only invisible and robust against common image processing operations such as sharpening, noise addition, and JPEG compression, etc, but also robust against global affine transforms and local geometric distortions

  7. Novel grid combined with peripheral distortion correction for ultra-widefield image grading of age-related macular degeneration

    Directory of Open Access Journals (Sweden)

    Oellers P

    2017-11-01

    Full Text Available Patrick Oellers,1,* Inês Laíns,1,2,* Steven Mach,1 Shady Garas,1 Ivana K Kim,1 Demetrios G Vavvas,1 Joan W Miller,1 Deeba Husain,1 John B Miller1 1Retina Service, Department of Ophthalmology, Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA; 2Faculty of Medicine, University of Coimbra, Coimbra, Portugal *These authors contributed equally to this work Purpose: Eyes with age-related macular degeneration (AMD often harbor pathological changes in the retinal periphery and perimacular region. These extramacular changes have not been well classified, but may be phenotypically and functionally relevant. The purpose of this study was to demonstrate a novel grid to systematically study peripheral retinal abnormalities in AMD using geometric distortion-corrected ultra-widefield (UWF imaging.Methods: This is a cross-sectional observational case series. Consecutive patients with AMD without any other coexisting vitreoretinal disease and control patients over age 50 without AMD or any other vitreoretinal disease were imaged using Optos 200 Tx. Captured 200° UWF images were corrected for peripheral geometric distortion using Optos transformation software. A newly developed grid to study perimacular and peripheral abnormalities in AMD was then projected onto the images.Results: Peripheral and perimacular changes such as drusen, retinal pigment epithelium changes and atrophy were found in patients with AMD. The presented grid in conjunction with geometric distortion-corrected UWF images allowed for systematic study of these peripheral changes in AMD.Conclusion: We present a novel grid to study peripheral and posterior pole changes in AMD. The grid is unique in that it adds a perimacular zone, which may be important in characterizing certain phenotypes in AMD. Our UWF images were corrected for geometric peripheral distortion to accurately reflect the anatomical dimensions of the retina. This grid offers a reliable and reproducible foundation

  8. Development and validation of a novel large field of view phantom and a software module for the quality assurance of geometric distortion in magnetic resonance imaging.

    Science.gov (United States)

    Torfeh, Tarraf; Hammoud, Rabih; McGarry, Maeve; Al-Hammadi, Noora; Perkins, Gregory

    2015-09-01

    To develop and validate a large field of view phantom and quality assurance software tool for the assessment and characterization of geometric distortion in MRI scanners commissioned for radiation therapy planning. A purpose built phantom was developed consisting of 357 rods (6mm in diameter) of polymethyl-methacrylat separated by 20mm intervals, providing a three dimensional array of control points at known spatial locations covering a large field of view up to a diameter of 420mm. An in-house software module was developed to allow automatic geometric distortion assessment. This software module was validated against a virtual dataset of the phantom that reproduced the exact geometry of the physical phantom, but with known translational and rotational displacements and warping. For validation experiments, clinical MRI sequences were acquired with and without the application of a commercial 3D distortion correction algorithm (Gradwarp™). The software module was used to characterize and assess system-related geometric distortion in the sequences relative to a benchmark CT dataset, and the efficacy of the vendor geometric distortion correction algorithms (GDC) was also assessed. Results issued from the validation of the software against virtual images demonstrate the algorithm's ability to accurately calculate geometric distortion with sub-pixel precision by the extraction of rods and quantization of displacements. Geometric distortion was assessed for the typical sequences used in radiotherapy applications and over a clinically relevant 420mm field of view (FOV). As expected and towards the edges of the field of view (FOV), distortion increased with increasing FOV. For all assessed sequences, the vendor GDC was able to reduce the mean distortion to below 1mm over a field of view of 5, 10, 15 and 20cm radius respectively. Results issued from the application of the developed phantoms and algorithms demonstrate a high level of precision. The results indicate that this

  9. Estimation of geometrically undistorted B0 inhomogeneity maps

    International Nuclear Information System (INIS)

    Matakos, A; Balter, J; Cao, Y

    2014-01-01

    Geometric accuracy of MRI is one of the main concerns for its use as a sole image modality in precision radiation therapy (RT) planning. In a state-of-the-art scanner, system level geometric distortions are within acceptable levels for precision RT. However, subject-induced B 0 inhomogeneity may vary substantially, especially in air-tissue interfaces. Recent studies have shown distortion levels of more than 2 mm near the sinus and ear canal are possible due to subject-induced field inhomogeneity. These distortions can be corrected with the use of accurate B 0 inhomogeneity field maps. Most existing methods estimate these field maps from dual gradient-echo (GRE) images acquired at two different echo-times under the assumption that the GRE images are practically undistorted. However distortion that may exist in the GRE images can result in estimated field maps that are distorted in both geometry and intensity, leading to inaccurate correction of clinical images. This work proposes a method for estimating undistorted field maps from GRE acquisitions using an iterative joint estimation technique. The proposed method yields geometrically corrected GRE images and undistorted field maps that can also be used for the correction of images acquired by other sequences. The proposed method is validated through simulation, phantom experiments and applied to patient data. Our simulation results show that our method reduces the root-mean-squared error of the estimated field map from the ground truth by ten-fold compared to the distorted field map. Both the geometric distortion and the intensity corruption (artifact) in the images caused by the B 0 field inhomogeneity are corrected almost completely. Our phantom experiment showed improvement in the geometric correction of approximately 1 mm at an air-water interface using the undistorted field map compared to using a distorted field map. The proposed method for undistorted field map estimation can lead to improved geometric

  10. Estimation of geometrically undistorted B0 inhomogeneity maps

    Science.gov (United States)

    Matakos, A.; Balter, J.; Cao, Y.

    2014-09-01

    Geometric accuracy of MRI is one of the main concerns for its use as a sole image modality in precision radiation therapy (RT) planning. In a state-of-the-art scanner, system level geometric distortions are within acceptable levels for precision RT. However, subject-induced B0 inhomogeneity may vary substantially, especially in air-tissue interfaces. Recent studies have shown distortion levels of more than 2 mm near the sinus and ear canal are possible due to subject-induced field inhomogeneity. These distortions can be corrected with the use of accurate B0 inhomogeneity field maps. Most existing methods estimate these field maps from dual gradient-echo (GRE) images acquired at two different echo-times under the assumption that the GRE images are practically undistorted. However distortion that may exist in the GRE images can result in estimated field maps that are distorted in both geometry and intensity, leading to inaccurate correction of clinical images. This work proposes a method for estimating undistorted field maps from GRE acquisitions using an iterative joint estimation technique. The proposed method yields geometrically corrected GRE images and undistorted field maps that can also be used for the correction of images acquired by other sequences. The proposed method is validated through simulation, phantom experiments and applied to patient data. Our simulation results show that our method reduces the root-mean-squared error of the estimated field map from the ground truth by ten-fold compared to the distorted field map. Both the geometric distortion and the intensity corruption (artifact) in the images caused by the B0 field inhomogeneity are corrected almost completely. Our phantom experiment showed improvement in the geometric correction of approximately 1 mm at an air-water interface using the undistorted field map compared to using a distorted field map. The proposed method for undistorted field map estimation can lead to improved geometric

  11. A Geometric Correction Method of Plane Image Based on OpenCV

    Directory of Open Access Journals (Sweden)

    Li Xiaopeng

    2014-02-01

    Full Text Available Using OpenCV, a geometric correction method of plane image from single grid image in a state of unknown camera position is presented. The method can remove the perspective and lens distortions from an image. The method is simple and easy to implement, and the efficiency is high. Experiments indicate that this method has high precision, and can be used in some domains such as plane measurement.

  12. Effects of image distortion correction on voxel-based morphometry

    International Nuclear Information System (INIS)

    Goto, Masami; Abe, Osamu; Kabasawa, Hiroyuki

    2012-01-01

    We aimed to show that correcting image distortion significantly affects brain volumetry using voxel-based morphometry (VBM) and to assess whether the processing of distortion correction reduces system dependency. We obtained contiguous sagittal T 1 -weighted images of the brain from 22 healthy participants using 1.5- and 3-tesla magnetic resonance (MR) scanners, preprocessed images using Statistical Parametric Mapping 5, and tested the relation between distortion correction and brain volume using VBM. Local brain volume significantly increased or decreased on corrected images compared with uncorrected images. In addition, the method used to correct image distortion for gradient nonlinearity produced fewer volumetric errors from MR system variation. This is the first VBM study to show more precise volumetry using VBM with corrected images. These results indicate that multi-scanner or multi-site imaging trials require correction for distortion induced by gradient nonlinearity. (author)

  13. Combined prospective and retrospective correction to reduce motion-induced image misalignment and geometric distortions in EPI.

    Science.gov (United States)

    Ooi, Melvyn B; Muraskin, Jordan; Zou, Xiaowei; Thomas, William J; Krueger, Sascha; Aksoy, Murat; Bammer, Roland; Brown, Truman R

    2013-03-01

    Despite rigid-body realignment to compensate for head motion during an echo-planar imaging time-series scan, nonrigid image deformations remain due to changes in the effective shim within the brain as the head moves through the B(0) field. The current work presents a combined prospective/retrospective solution to reduce both rigid and nonrigid components of this motion-related image misalignment. Prospective rigid-body correction, where the scan-plane orientation is dynamically updated to track with the subject's head, is performed using an active marker setup. Retrospective distortion correction is then applied to unwarp the remaining nonrigid image deformations caused by motion-induced field changes. Distortion correction relative to a reference time-frame does not require any additional field mapping scans or models, but rather uses the phase information from the echo-planar imaging time-series itself. This combined method is applied to compensate echo-planar imaging scans of volunteers performing in-plane and through-plane head motions, resulting in increased image stability beyond what either prospective or retrospective rigid-body correction alone can achieve. The combined method is also assessed in a blood oxygen level dependent functional MRI task, resulting in improved Z-score statistics. Copyright © 2012 Wiley Periodicals, Inc.

  14. A method to correct coordinate distortion in EBSD maps

    International Nuclear Information System (INIS)

    Zhang, Y.B.; Elbrønd, A.; Lin, F.X.

    2014-01-01

    Drift during electron backscatter diffraction mapping leads to coordinate distortions in resulting orientation maps, which affects, in some cases significantly, the accuracy of analysis. A method, thin plate spline, is introduced and tested to correct such coordinate distortions in the maps after the electron backscatter diffraction measurements. The accuracy of the correction as well as theoretical and practical aspects of using the thin plate spline method is discussed in detail. By comparing with other correction methods, it is shown that the thin plate spline method is most efficient to correct different local distortions in the electron backscatter diffraction maps. - Highlights: • A new method is suggested to correct nonlinear spatial distortion in EBSD maps. • The method corrects EBSD maps more precisely than presently available methods. • Errors less than 1–2 pixels are typically obtained. • Direct quantitative analysis of dynamic data are available after this correction

  15. An application of the baseline correction technique for correcting distorted seismic acceleration time histories

    International Nuclear Information System (INIS)

    Lee, Gyu Mahn; Kim, Jong Wook; Jeoung, Kyeong Hoon; Kim, Tae Wan; Park, Keun Bae; Kim, Keung Koo

    2008-03-01

    Three kinds of baseline correction techniques named as 'Newmark', 'Zero-VD' and 'Newmark and Zero-VD' were introduced to correct the distorted physical characteristics of a seismic time history accelogram. The corrected seismic accelerations and distorted raw acceleration showed an identical response spectra in frequency domains, but showed various time history profiles in velocity and displacement domains. The referred correction techniques were programmed with UNIX-HP Fortran. The verification of the baseline corrected seismic data in terms of frequency response spectrum were performed by ANSYS of a commerical FEM software

  16. A method to correct coordinate distortion in EBSD maps

    DEFF Research Database (Denmark)

    Zhang, Yubin; Elbrønd, Andreas Benjamin; Lin, Fengxiang

    2014-01-01

    Drift during electron backscatter diffraction mapping leads to coordinate distortions in resulting orientation maps, which affects, in some cases significantly, the accuracy of analysis. A method, thin plate spline, is introduced and tested to correct such coordinate distortions in the maps after...... the electron backscatter diffraction measurements. The accuracy of the correction as well as theoretical and practical aspects of using the thin plate spline method is discussed in detail. By comparing with other correction methods, it is shown that the thin plate spline method is most efficient to correct...

  17. A method based on moving least squares for XRII image distortion correction

    International Nuclear Information System (INIS)

    Yan Shiju; Wang Chengtao; Ye Ming

    2007-01-01

    This paper presents a novel integrated method to correct geometric distortions of XRII (x-ray image intensifier) images. The method has been compared, in terms of mean-squared residual error measured at control and intermediate points, with two traditional local methods and a traditional global methods. The proposed method is based on the methods of moving least squares (MLS) and polynomial fitting. Extensive experiments were performed on simulated and real XRII images. In simulation, the effect of pincushion distortion, sigmoidal distortion, local distortion, noise, and the number of control points was tested. The traditional local methods were sensitive to pincushion and sigmoidal distortion. The traditional global method was only sensitive to sigmoidal distortion. The proposed method was found neither sensitive to pincushion distortion nor sensitive to sigmoidal distortion. The sensitivity of the proposed method to local distortion was lower than or comparable with that of the traditional global method. The sensitivity of the proposed method to noise was higher than that of all three traditional methods. Nevertheless, provided the standard deviation of noise was not greater than 0.1 pixels, accuracy of the proposed method is still higher than the traditional methods. The sensitivity of the proposed method to the number of control points was greatly lower than that of the traditional methods. Provided that a proper cutoff radius is chosen, accuracy of the proposed method is higher than that of the traditional methods. Experiments on real images, carried out by using a 9 in. XRII, showed that residual error of the proposed method (0.2544±0.2479 pixels) is lower than that of the traditional global method (0.4223±0.3879 pixels) and local methods (0.4555±0.3518 pixels and 0.3696±0.4019 pixels, respectively)

  18. Correcting the Chromatic Aberration in Barrel Distortion of Endoscopic Images

    Directory of Open Access Journals (Sweden)

    Y. M. Harry Ng

    2003-04-01

    Full Text Available Modern endoscopes offer physicians a wide-angle field of view (FOV for minimally invasive therapies. However, the high level of barrel distortion may prevent accurate perception of image. Fortunately, this kind of distortion may be corrected by digital image processing. In this paper we investigate the chromatic aberrations in the barrel distortion of endoscopic images. In the past, chromatic aberration in endoscopes is corrected by achromatic lenses or active lens control. In contrast, we take a computational approach by modifying the concept of image warping and the existing barrel distortion correction algorithm to tackle the chromatic aberration problem. In addition, an error function for the determination of the level of centroid coincidence is proposed. Simulation and experimental results confirm the effectiveness of our method.

  19. Real-time distortion correction for visual inspection systems based on FPGA

    Science.gov (United States)

    Liang, Danhua; Zhang, Zhaoxia; Chen, Xiaodong; Yu, Daoyin

    2008-03-01

    Visual inspection is a kind of new technology based on the research of computer vision, which focuses on the measurement of the object's geometry and location. It can be widely used in online measurement, and other real-time measurement process. Because of the defects of the traditional visual inspection, a new visual detection mode -all-digital intelligent acquisition and transmission is presented. The image processing, including filtering, image compression, binarization, edge detection and distortion correction, can be completed in the programmable devices -FPGA. As the wide-field angle lens is adopted in the system, the output images have serious distortion. Limited by the calculating speed of computer, software can only correct the distortion of static images but not the distortion of dynamic images. To reach the real-time need, we design a distortion correction system based on FPGA. The method of hardware distortion correction is that the spatial correction data are calculated first under software circumstance, then converted into the address of hardware storage and stored in the hardware look-up table, through which data can be read out to correct gray level. The major benefit using FPGA is that the same circuit can be used for other circularly symmetric wide-angle lenses without being modified.

  20. Two dimensional spatial distortion correction algorithm for scintillation GAMMA cameras

    International Nuclear Information System (INIS)

    Chaney, R.; Gray, E.; Jih, F.; King, S.E.; Lim, C.B.

    1985-01-01

    Spatial distortion in an Anger gamma camera originates fundamentally from the discrete nature of scintillation light sampling with an array of PMT's. Historically digital distortion correction started with the method based on the distortion measurement by using 1-D slit pattern and the subsequent on-line bi-linear approximation with 64 x 64 look-up tables for X and Y. However, the X, Y distortions are inherently two-dimensional in nature, and thus the validity of this 1-D calibration method becomes questionable with the increasing distortion amplitude in association with the effort to get better spatial and energy resolutions. The authors have developed a new accurate 2-D correction algorithm. This method involves the steps of; data collection from 2-D orthogonal hole pattern, 2-D distortion vector measurement, 2-D Lagrangian polynomial interpolation, and transformation to X, Y ADC frame. The impact of numerical precision used in correction and the accuracy of bilinear approximation with varying look-up table size have been carefully examined through computer simulation by using measured single PMT light response function together with Anger positioning logic. Also the accuracy level of different order Lagrangian polynomial interpolations for correction table expansion from hole centroids were investigated. Detailed algorithm and computer simulation are presented along with camera test results

  1. MRI, geometric distortion of the image and stereotaxy

    International Nuclear Information System (INIS)

    Derosier, C.; Delegue, G.; Munier, T.; Pharaboz, C.; Cosnard, G.

    1991-01-01

    The MRI technology may be the starting-point of geometric distortion. The mathematical preciseness of a spatial location may be disturbed and alter the guidance of a MRI interventional act, especially in stereotactic brain biopsy. A review of the literature shows errors of 1 to 1.5 mm. Our results show an error of 0.16±0.66. The control of quality: homogeneity and calibration of magnetic-field gradients, permit an improve of the ballistic preciseness and give permission to realize the guidance of a stereotactic brain biopsy with the alone MRI

  2. A New Quaternion-Based Kalman Filter for Real-Time Attitude Estimation Using the Two-Step Geometrically-Intuitive Correction Algorithm.

    Science.gov (United States)

    Feng, Kaiqiang; Li, Jie; Zhang, Xiaoming; Shen, Chong; Bi, Yu; Zheng, Tao; Liu, Jun

    2017-09-19

    In order to reduce the computational complexity, and improve the pitch/roll estimation accuracy of the low-cost attitude heading reference system (AHRS) under conditions of magnetic-distortion, a novel linear Kalman filter, suitable for nonlinear attitude estimation, is proposed in this paper. The new algorithm is the combination of two-step geometrically-intuitive correction (TGIC) and the Kalman filter. In the proposed algorithm, the sequential two-step geometrically-intuitive correction scheme is used to make the current estimation of pitch/roll immune to magnetic distortion. Meanwhile, the TGIC produces a computed quaternion input for the Kalman filter, which avoids the linearization error of measurement equations and reduces the computational complexity. Several experiments have been carried out to validate the performance of the filter design. The results demonstrate that the mean time consumption and the root mean square error (RMSE) of pitch/roll estimation under magnetic disturbances are reduced by 45.9% and 33.8%, respectively, when compared with a standard filter. In addition, the proposed filter is applicable for attitude estimation under various dynamic conditions.

  3. Color correction for chromatic distortion in a multi-wavelength digital holographic system

    International Nuclear Information System (INIS)

    Lin, Li-Chien; Huang, Yi-Lun; Tu, Han-Yen; Lai, Xin-Ji; Cheng, Chau-Jern

    2011-01-01

    A multi-wavelength digital holographic (MWDH) system has been developed to record and reconstruct color images. In comparison to working with digital cameras, however, high-quality color reproduction is difficult to achieve, because of the imperfections from the light sources, optical components, optical recording devices and recording processes. Thus, we face the problem of correcting the colors altered during the digital holographic process. We therefore propose a color correction scheme to correct the chromatic distortion caused by the MWDH system. The scheme consists of two steps: (1) creating a color correction profile and (2) applying it to the correction of the distorted colors. To create the color correction profile, we generate two algorithms: the sequential algorithm and the integrated algorithm. The ColorChecker is used to generate the distorted colors and their desired corrected colors. The relationship between these two color patches is fixed into a specific mathematical model, the parameters of which are estimated, creating the profile. Next, the profile is used to correct the color distortion of images, capturing and preserving the original vibrancy of the reproduced colors for different reconstructed images

  4. Optical traps with geometric aberrations

    International Nuclear Information System (INIS)

    Roichman, Yael; Waldron, Alex; Gardel, Emily; Grier, David G.

    2006-01-01

    We assess the influence of geometric aberrations on the in-plane performance of optical traps by studying the dynamics of trapped colloidal spheres in deliberately distorted holographic optical tweezers. The lateral stiffness of the traps turns out to be insensitive to moderate amounts of coma, astigmatism, and spherical aberration. Moreover holographic aberration correction enables us to compensate inherent shortcomings in the optical train, thereby adaptively improving its performance. We also demonstrate the effects of geometric aberrations on the intensity profiles of optical vortices, whose readily measured deformations suggest a method for rapidly estimating and correcting geometric aberrations in holographic trapping systems

  5. SU-G-IeP1-08: MR Geometric Distortion Dependency On Imaging Sequence, Acquisition Orientation and Receiver Bandwidth of a Dedicated 1.5T MR-Simulator

    International Nuclear Information System (INIS)

    Law, M; Yuan, J; Wong, O; Yu, S

    2016-01-01

    Purpose: To investigate the 3D geometric distortion of four potential MR sequences for radiotheraptic applications, and its dependency on sequence-type, acquisition-orientation and receiver-bandwidth from a dedicated 1.5T 700mm-wide bore MR-simulator (Magnetom-Aera, Sienmens Healthcare, Erlangen, Germany), using a large customized geometric accuracy phantom. Methods: This work studied 3D gradient-echo (VIBE) and spin-echo (SPACE) sequences for anatomical imaging; a specific ultra-short-TE sequence (PETRA) potentially for bone imaging and MR-based dosimetry; and a motion-insensitive sequence (BLADE) for dynamic applications like 4D-MRI. Integrated geometric-correction was employed, three orthogonal acquisition-orientations and up to three receiver-bandwidths were used, yielding 27 acquisitions for testing (Table 1a).A customized geometric accuracy phantom (polyurethane, MR/CT invisible, W×L×H:55×55×32.5cm3) was constructed and filled with 3892 spherical markers (6mm diameter, MR/CT visible) arranged on a 25mm-interval 3D isotropic-grid (Fig.1). The marker positions in MR images were quantitatively calculated and compared against those in the CT-reference using customized MatLab scripts. Results: The average distortion within various diameter-of-spherical-volumes (DSVs) and the usable DSVs under various distortion limits were measured (Tables 1b-c). It was observed that distortions fluctuated when sequence-type, acquisition-orientation or receiver-bandwidth changed (e.g. within 300mm-DSV, the lowest/highest average distortions of VIBE were 0.40mm/0.59mm, a 47.5% difference). According to AAPM-TG66 (<1mm distortion, left-most column of Table 1c), PETRA (Largest-DSV:253.9mm) has the potential on brain treatment, while BLADE (Largest-DSV:207.2mm) may need improvement for thoracic/abdominal applications. The results of VIBE (Largest-DSVs:294.3mm, the best among tested acquisitions) and SPACE (Largest-DSVs:267.7mm) suggests their potentials on head and neck

  6. SU-G-IeP1-08: MR Geometric Distortion Dependency On Imaging Sequence, Acquisition Orientation and Receiver Bandwidth of a Dedicated 1.5T MR-Simulator

    Energy Technology Data Exchange (ETDEWEB)

    Law, M; Yuan, J; Wong, O; Yu, S [Hong Kong Sanatorium & Hospital, Hong Kong, Hong Kong (Hong Kong)

    2016-06-15

    Purpose: To investigate the 3D geometric distortion of four potential MR sequences for radiotheraptic applications, and its dependency on sequence-type, acquisition-orientation and receiver-bandwidth from a dedicated 1.5T 700mm-wide bore MR-simulator (Magnetom-Aera, Sienmens Healthcare, Erlangen, Germany), using a large customized geometric accuracy phantom. Methods: This work studied 3D gradient-echo (VIBE) and spin-echo (SPACE) sequences for anatomical imaging; a specific ultra-short-TE sequence (PETRA) potentially for bone imaging and MR-based dosimetry; and a motion-insensitive sequence (BLADE) for dynamic applications like 4D-MRI. Integrated geometric-correction was employed, three orthogonal acquisition-orientations and up to three receiver-bandwidths were used, yielding 27 acquisitions for testing (Table 1a).A customized geometric accuracy phantom (polyurethane, MR/CT invisible, W×L×H:55×55×32.5cm3) was constructed and filled with 3892 spherical markers (6mm diameter, MR/CT visible) arranged on a 25mm-interval 3D isotropic-grid (Fig.1). The marker positions in MR images were quantitatively calculated and compared against those in the CT-reference using customized MatLab scripts. Results: The average distortion within various diameter-of-spherical-volumes (DSVs) and the usable DSVs under various distortion limits were measured (Tables 1b-c). It was observed that distortions fluctuated when sequence-type, acquisition-orientation or receiver-bandwidth changed (e.g. within 300mm-DSV, the lowest/highest average distortions of VIBE were 0.40mm/0.59mm, a 47.5% difference). According to AAPM-TG66 (<1mm distortion, left-most column of Table 1c), PETRA (Largest-DSV:253.9mm) has the potential on brain treatment, while BLADE (Largest-DSV:207.2mm) may need improvement for thoracic/abdominal applications. The results of VIBE (Largest-DSVs:294.3mm, the best among tested acquisitions) and SPACE (Largest-DSVs:267.7mm) suggests their potentials on head and neck

  7. SU-E-J-220: Assessment of MRI Geometric Distortion in Head and Neck Cancer Patients Scanned in Immobilized Radiation Treatment Position

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, C; Mohamed, A; Weygand, J; Ding, Y; Fuller, C; Frank, S; Wang, J [MD Anderson Cancer Center, Houston, TX (United States)

    2015-06-15

    Purpose: Uncertainties about geometric distortion have somewhat hindered MRI simulation in radiation therapy. Most of the geometric distortion studies were performed with phantom measurements but another major aspect of MR distortion is patient related. We studied the geometric distortion in patient images by comparing their MRI scans with the corresponding CT, using CT as the non-distorted gold standard. Methods: Ten H&N cancer patients were imaged with MRI as part of a prospective IRB approved study. All patients had their treatment planning CT done on the same day or within one week of the MRI. MR Images were acquired with a T2 SE sequence (1×1×2.5mm voxel size) in the same immobilization position as in the CT scans. MRI to CT rigid registration was then done and geometric distortion comparison was done by measuring the corresponding anatomical landmarks on both the MRI and the CT images by two observers. Several skin to skin (9 landmarks), bone to bone (8 landmarks), and soft tissue (3 landmarks) were measured at specific levels in horizontal and vertical planes of both scans. Results: The mean distortion for all landmark measurements in all scans was 1.8±1.9mm. For each patient 11 measurements were done in the horizontal plane while 9 were done in the vertical plane. The measured geometric distortion were significantly lower in the horizontal axis compared to the vertical axis (1.3±0.16 mm vs 2.2±0.19 mm, respectively, P=0.003*). The magnitude of distortion was lower in the bone to bone landmarks compared to the combined soft tissue and skin to skin landmarks (1.2±0.19 mm vs 2.3±0.17 mm, P=0.0006*). The mean distortion measured by observer one was not significantly different compared toobserver 2 (2.3 vs 2.4 mm, P=0.4). Conclusion: MRI geometric distortions were quantified in H&N patients with mean error of less than 2 mm. JW received a corporate sponsored research grant from Elekta.

  8. Effects of Field-Map Distortion Correction on Resting State Functional Connectivity MRI

    Directory of Open Access Journals (Sweden)

    Hiroki Togo

    2017-12-01

    Full Text Available Magnetic field inhomogeneities cause geometric distortions of echo planar images used for functional magnetic resonance imaging (fMRI. To reduce this problem, distortion correction (DC with field map is widely used for both task and resting-state fMRI (rs-fMRI. Although DC with field map has been reported to improve the quality of task fMRI, little is known about its effects on rs-fMRI. Here, we tested the influence of field-map DC on rs-fMRI results using two rs-fMRI datasets derived from 40 healthy subjects: one with DC (DC+ and the other without correction (DC−. Independent component analysis followed by the dual regression approach was used for evaluation of resting-state functional connectivity networks (RSN. We also obtained the ratio of low-frequency to high-frequency signal power (0.01–0.1 Hz and above 0.1 Hz, respectively; LFHF ratio to assess the quality of rs-fMRI signals. For comparison of RSN between DC+ and DC− datasets, the default mode network showed more robust functional connectivity in the DC+ dataset than the DC− dataset. Basal ganglia RSN showed some decreases in functional connectivity primarily in white matter, indicating imperfect registration/normalization without DC. Supplementary seed-based and simulation analyses supported the utility of DC. Furthermore, we found a higher LFHF ratio after field map correction in the anterior cingulate cortex, posterior cingulate cortex, ventral striatum, and cerebellum. In conclusion, field map DC improved detection of functional connectivity derived from low-frequency rs-fMRI signals. We encourage researchers to include a DC step in the preprocessing pipeline of rs-fMRI analysis.

  9. SU-E-J-209: Geometric Distortion at 3T in a Commercial 4D MRI-Compatible Phantom

    International Nuclear Information System (INIS)

    Fatemi-Ardekani, A; Wronski, M; Kim, A; Stanisz, G; Sarfehnia, A; Keller, B

    2015-01-01

    Purpose: There are very few commercial 4D phantoms that are marketed as MRI compatible. We are evaluating one such commercial phantom, made to be used with an MRI-Linear accelerator. The focus of this work is to characterize the geometric distortions produced in this phantom at 3T using 3 clinical MR pulse sequences. Methods: The CIRS MRI-Linac Dynamic Phantom (CIRSTM) under investigation in this study consists of a softwaredriven moving tumour volume within a thorax phantom body and enables dose accumulation by placing a dosimeter within the tumour volume. Our initial investigation is to evaluate the phantom in static mode prior to examining its 4D capability. The water-filled thorax phantom was scanned using a wide-bore Philips 3T Achieva MRI scanner employing a Thoracic xl coil and clinical 2D T1W FFE, 2D T1W TSE and 3D T1W TFE pulse sequences. Each of the MR image sets was rigidly fused with a reference CT image of the phantom employing a rigid registration with 6 degrees of freedom. Geometric distortions between the MR and CT image sets were measured in 3 dimensions at selected points along the periphery of the distortion grid embedded within the phantom body (11.5, 7.5 and 3 cm laterally, ant/post and sup/inf of magnetic isocenter respectively). Results: The maximal measured geometric distortions between the MR and reference CT points of interest were 0.9, 1.8 and 1.3 mm in the lateral, anteriorposterior and cranio-caudal directions, respectively. For all 3 spatial dimensions, the maximal distortions occurred for the FFE pulse sequence. Maximal distortions for the 2D FFE, 2D TSE and 3D TFE sequences were 1, 0.7 and 1.8 mm, respectively. Conclusion: Our initial static investigation of this phantom shows minimal geometric distortions at 3T along the periphery of the embedded grid. CIRS has provided us with a phantom at no charge for evaluation at 3 Tesla

  10. Multiview Trajectory Mapping Using Homography with Lens Distortion Correction

    Directory of Open Access Journals (Sweden)

    Andrea Cavallaro

    2008-11-01

    Full Text Available We present a trajectory mapping algorithm for a distributed camera setting that is based on statistical homography estimation accounting for the distortion introduced by camera lenses. Unlike traditional approaches based on the direct linear transformation (DLT algorithm and singular value decomposition (SVD, the planar homography estimation is derived from renormalization. In addition to this, the algorithm explicitly introduces a correction parameter to account for the nonlinear radial lens distortion, thus improving the accuracy of the transformation. We demonstrate the proposed algorithm by generating mosaics of the observed scenes and by registering the spatial locations of moving objects (trajectories from multiple cameras on the mosaics. Moreover, we objectively compare the transformed trajectories with those obtained by SVD and least mean square (LMS methods on standard datasets and demonstrate the advantages of the renormalization and the lens distortion correction.

  11. Multiview Trajectory Mapping Using Homography with Lens Distortion Correction

    Directory of Open Access Journals (Sweden)

    Kayumbi Gabin

    2008-01-01

    Full Text Available Abstract We present a trajectory mapping algorithm for a distributed camera setting that is based on statistical homography estimation accounting for the distortion introduced by camera lenses. Unlike traditional approaches based on the direct linear transformation (DLT algorithm and singular value decomposition (SVD, the planar homography estimation is derived from renormalization. In addition to this, the algorithm explicitly introduces a correction parameter to account for the nonlinear radial lens distortion, thus improving the accuracy of the transformation. We demonstrate the proposed algorithm by generating mosaics of the observed scenes and by registering the spatial locations of moving objects (trajectories from multiple cameras on the mosaics. Moreover, we objectively compare the transformed trajectories with those obtained by SVD and least mean square (LMS methods on standard datasets and demonstrate the advantages of the renormalization and the lens distortion correction.

  12. Geometric Correction of PHI Hyperspectral Image without Ground Control Points

    International Nuclear Information System (INIS)

    Luan, Kuifeng; Tong, Xiaohua; Liu, Xiangfeng; Ma, Yanhua; Shu, Rong; Xu, Weiming

    2014-01-01

    Geometric correction without ground control points (GCPs) is a very important topic. Conventional airborne photogrammetry is difficult to implement in areas where the installation of GCPs is not available. The technical of integrated GPS/INS systems providing the positioning and attitude of airborne systems is a potential solution in such areas. This paper first states the principle of geometric correction based on a combination of GPS and INS then the error of the geometric correction of Pushbroom Hyperspectral Imager (PHI) without GCP was analysed, then a flight test was carried out in an area of Damxung, Tibet. The experiment result showed that the error at straight track was small, generally less than 1 pixel, while the maximum error at cross track direction, was close to 2 pixels. The results show that geometric correction of PHI without GCP enables a variety of mapping products to be generated from airborne navigation and imagery data

  13. Correction for polychromatic X-ray image distortion in computer tomography images

    International Nuclear Information System (INIS)

    1979-01-01

    A method and apparatus are described which correct the polychromatic distortion of CT images that is produced by the non-linear interaction of body constituents with a polychromatic X-ray beam. A CT image is processed to estimate the proportion of the attenuation coefficients of the constituents in each pixel element. A multiplicity of projections for each constituent are generated from the original image and are combined utilizing a multidimensional polynomial which approximates the non-linear interaction involved. An error image is then generated from the combined projections and is subtracted from the original image to correct for the polychromatic distortion. (Auth.)

  14. Radial lens distortion correction with sub-pixel accuracy for X-ray micro-tomography.

    Science.gov (United States)

    Vo, Nghia T; Atwood, Robert C; Drakopoulos, Michael

    2015-12-14

    Distortion correction or camera calibration for an imaging system which is highly configurable and requires frequent disassembly for maintenance or replacement of parts needs a speedy method for recalibration. Here we present direct techniques for calculating distortion parameters of a non-linear model based on the correct determination of the center of distortion. These techniques are fast, very easy to implement, and accurate at sub-pixel level. The implementation at the X-ray tomography system of the I12 beamline, Diamond Light Source, which strictly requires sub-pixel accuracy, shows excellent performance in the calibration image and in the reconstructed images.

  15. [Signal analysis and spectrum distortion correction for tunable diode laser absorption spectroscopy system].

    Science.gov (United States)

    Bao, Wei-Yi; Zhu, Yong; Chen, Jun; Chen, Jun-Qing; Liang, Bo

    2011-04-01

    In the present paper, the signal of a tunable diode laser absorption spectroscopy (TDLAS) trace gas sensing system, which has a wavelength modulation with a wide range of modulation amplitudes, is studied based on Fourier analysis method. Theory explanation of spectrum distortion induced by laser intensity amplitude modulation is given. In order to rectify the spectrum distortion, a method of synchronous amplitude modulation suppression by a variable optical attenuator is proposed. To validate the method, an experimental setup is designed. Absorption spectrum measurement experiments on CO2 gas were carried out. The results show that the residual laser intensity modulation amplitude of the experimental system is reduced to -0.1% of its original value and the spectrum distortion improvement is 92% with the synchronous amplitude modulation suppression. The modulation amplitude of laser intensity can be effectively reduced and the spectrum distortion can be well corrected by using the given correction method and system. By using a variable optical attenuator in the TDLAS (tunable diode laser absorption spectroscopy) system, the dynamic range requirements of photoelectric detector, digital to analog converter, filters and other aspects of the TDLAS system are reduced. This spectrum distortion correction method can be used for online trace gas analyzing in process industry.

  16. TU-H-206-07: Assessment of Geometric Distortion in EPI with a SPAMM Tagged Acquisition

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, K; Meier, J; Yung, J; Stafford, R [The University of Texas MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: Echo planar imaging (EPI) is known to exhibit gross geometric distortion caused by multiple factors, including B0 inhomgeneity and transient eddy currents. However, diffusion weighted (DW) EPI has become indispensable for diagnosis and therapy assessment. We propose a methodology for quantifying distortion in EPI sequences that does not require the use of dedicated spatial accuracy phantoms, enabling flexibility in phantom design for QA of distortion effects in EPI protocols. Methods: The proposed methodology utilizes a saturation technique known as Spatial Modulation of Magnetization (SPAMM) that tags the imaging subject with saturated grid lines. Originally intended for tracking cardiac motion, these grids are applied to assess differences between diffusion weighting directions and b-values, or against a more geometrically robust sequence such as fast spin echo (FSE). The saturation preparation sequence consists of binomially weighted (e.g. 1-3-3-1) pulses interleaved with gradient blips along the frequency encode direction, followed by the same sequence with gradient blips in the phase encode direction. Three phantoms were assessed with these sequences: a spherical head-sized phantom, a large shimming phantom, and a modified PET ACR phantom that included compartments of water, air, oil, and Teflon. Each phantom was acquired with three sequences using parameters from a clinically appropriate protocol (22 cm head or 46 cm abdomen): a conventional DW-EPI sequence (3 DW directions), and both the DW-EPI and FSE sequences with tagging. Differences in grid locations were visualized with minimum intensity projection between images, and measured using intersecting locations on the grids. Results: Grid lines were clearly visualized on tagged images and enabled quantification of distortions. Maximum eddy current induced errors of 10.8 to 14.8 mm were observed in areas away from isocenter with DW gradients applied in various directions. Conclusion: SPAMM tagging

  17. Geometrical optics in general relativity: A study of the higher order corrections

    International Nuclear Information System (INIS)

    Anile, A.M.

    1976-01-01

    The higher order corrections to geometrical optics are studied in general relativity for an electromagnetic test wave. An explicit expression is found for the average energy--momentum tensor which takes into account the first-order corrections. Finally the first-order corrections to the well-known area-intensity law of geometrical optics are derived

  18. TPC track distortions: correction maps for magnetic and static electric inhomogeneities

    CERN Document Server

    Dydak, F; Nefedov, Y

    2003-01-01

    Inhomogeneities of the magnetic and electric fields in the active TPC volume lead to displacements of cluster coordinates, and therefore to track distortions. In case of good data taking conditions, the largest effects are expected from the inhomogeneity of the solenoidal magnetic field, and from a distortion of the electric field arising from a high voltage misalignment between the outer and inner field cages. Both effects are stable over the entire HARP data taking. The displacements are large compared to the azimuthal coordinate resolution but can be corrected with sufficient precision, except at small TPC radius. The high voltage misalignment between the outer and inner field cages is identified as the likely primary cause of sagitta distortions of TPC tracks. The position and the length of the target plays an important role. Based on a detailed modelling of the magnetic and static electric field inhomogeneities, precise correction maps for both effects have been calculated. Predictions from the correctio...

  19. An Iterative Optimization Algorithm for Lens Distortion Correction Using Two-Parameter Models

    Directory of Open Access Journals (Sweden)

    Daniel Santana-Cedrés

    2016-12-01

    Full Text Available We present a method for the automatic estimation of two-parameter radial distortion models, considering polynomial as well as division models. The method first detects the longest distorted lines within the image by applying the Hough transform enriched with a radial distortion parameter. From these lines, the first distortion parameter is estimated, then we initialize the second distortion parameter to zero and the two-parameter model is embedded into an iterative nonlinear optimization process to improve the estimation. This optimization aims at reducing the distance from the edge points to the lines, adjusting two distortion parameters as well as the coordinates of the center of distortion. Furthermore, this allows detecting more points belonging to the distorted lines, so that the Hough transform is iteratively repeated to extract a better set of lines until no improvement is achieved. We present some experiments on real images with significant distortion to show the ability of the proposed approach to automatically correct this type of distortion as well as a comparison between the polynomial and division models.

  20. Diffusion tensor imaging of the brain. Effects of distortion correction with correspondence to numbers of encoding directions

    International Nuclear Information System (INIS)

    Yoshikawa, Takeharu; Aoki, Shigeki; Abe, Osamu; Hayashi, Naoto; Masutani, Yoshitaka; Masumoto, Tomohiko; Mori, Harushi; Satake, Yoshiroh; Ohtomo, Kuni

    2008-01-01

    The aim of the study was to estimate the effect of distortion correction with correspondence to numbers of encoding directions to acquire diffusion tensor imaging (DTI) of improved quality. Ten volunteers underwent DTI of the head using echo planar imaging with 6, 13, 27, and 55 encoding directions. Fractional anisotropy (FA) maps and apparent diffusion coefficient (ADC) maps were created before and after distortion correction. Regions of interest were placed in the corpus callosum on each map, and standard deviations of FA and ADC were calculated. FA maps were also evaluated visually by experienced neuroradiologists. Dispersion of standard deviations tended to be reduced after distortion correction, with significant differences found in FA maps with 6 encoding directions, ADC maps with 6 directions, and ADC maps with 13 directions (P<0.001, P<0.005, and P<0.05, respectively). Visual image quality was improved after distortion correction (P<0.01 for all of the visual comparisons). Distortion correction is effective in providing DTI of enhanced quality, notwithstanding the number of encoding directions. (author)

  1. Quantitative studies with the gamma-camera: correction for spatial and energy distortion

    International Nuclear Information System (INIS)

    Soussaline, F.; Todd-Pokropek, A.E.; Raynaud, C.

    1977-01-01

    The gamma camera sensitivity distribution is an important source of error in quantitative studies. In addition, spatial distortion produces apparent variations in count density which degrades quantitative studies. The flood field image takes into account both effects and is influenced by the pile-up of the tail distribution. It is essential to measure separately each of these parameters. These were investigated using a point source displaced by a special scanning table with two X, Y stepping motors of 10 micron precision. The spatial distribution of the sensitivity, spatial distortion and photopeak in the field of view were measured and compared for different setting-up of the camera and PM gains. For well-tuned cameras, the sensitivity is fairly constant, while the variations appearing in the flood field image are primarily due to spatial distortion, the former more dependent than the latter on the energy window setting. This indicates why conventional flood field uniformity correction must not be applied. A correction technique to improve the results in quantitative studies has been tested using a continuously matched energy window at every point within the field. A method for correcting spatial distortion is also proposed, where, after an adequately sampled measurement of this error, a transformation can be applied to calculate the true position of events. The knowledge of the magnitude of these parameters is essential in the routine use and design of detector systems

  2. COMPARISON OF METHODS FOR GEOMETRIC CAMERA CALIBRATION

    Directory of Open Access Journals (Sweden)

    J. Hieronymus

    2012-09-01

    Full Text Available Methods for geometric calibration of cameras in close-range photogrammetry are established and well investigated. The most common one is based on test-fields with well-known pattern, which are observed from different directions. The parameters of a distortion model are calculated using bundle-block-adjustment-algorithms. This methods works well for short focal lengths, but is essentially more problematic to use with large focal lengths. Those would require very large test-fields and surrounding space. To overcome this problem, there is another common method for calibration used in remote sensing. It employs measurements using collimator and a goniometer. A third calibration method uses diffractive optical elements (DOE to project holograms of well known pattern. In this paper these three calibration methods are compared empirically, especially in terms of accuracy. A camera has been calibrated with those methods mentioned above. All methods provide a set of distortion correction parameters as used by the photogrammetric software Australis. The resulting parameter values are very similar for all investigated methods. The three sets of distortion parameters are crosscompared against all three calibration methods. This is achieved by inserting the gained distortion parameters as fixed input into the calibration algorithms and only adjusting the exterior orientation. The RMS (root mean square of the remaining image coordinate residuals are taken as a measure of distortion correction quality. There are differences resulting from the different calibration methods. Nevertheless the measure is small for every comparison, which means that all three calibration methods can be used for accurate geometric calibration.

  3. Geometric distortion of F255W for WFPC2 Cycle 12

    Science.gov (United States)

    Kozhurina-Platais, Vera

    2003-07-01

    The goal of astrometric calibration of the HST WFPC2 is to obtain a coordinate system free of distortion down to the precision level of 1 mas. That precision is necessary for future astrometric work {e.g., on proper motions} involving a combination of the archival WFPC2 and recent ACS images. So far such a calibration has only been obtained for the wide bandpass F555W filter {Anderson and King, 2003}. Recently V. Kozhurina-Platais {ISR, 2003-002} has expanded the analysis of the geometric distortion of WFPC2 as a function of wavelength for two other broadband filters, {F814W and F300W}, and has also established the plate scale and skew parameters {non-perpendicularity of X and Y axes} for these filters. This study points to the importance of astrometric calibration at wavelengths shorter than 400 nanometers. This proposal seeks observations in the FUV filter F255W of the Inner Calibration Field in the globular cluster omega Cen. It is expected that the amount of distortion in the F255W filter with respect to the F555W filter will be higher by 5% but this must be established from observations. A total of four astrometric calibrations in F255W {proposed here}, and F300W, F555, F814W {already completed} will allow us to interpolate such a calibration for any other filter from FUV to near infrared.

  4. Effect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI

    Directory of Open Access Journals (Sweden)

    Golestan karami

    2013-03-01

    Full Text Available Introduction Echo-planar imaging (EPI is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that causes more geometric distortion in phase encoding direction. This inhomogeneity is induced mainly by the magnetic susceptibility differences between various structures within the object placed inside the scanner, often at air-tissue or bone-tissue interfaces. Methods of reducing EPI distortion are mainly based on decreasing steps of the phase encoding. Reducing steps of phase encoding can be applied by reducing field of view, slice thickness, and/or the use of parallel acquisition technique. Materials and Methods We obtained three data acquisitions with different FOVs including: conventional low resolution, conventional high resolution, and zoomed high resolution EPIs. Moreover we used SENSE technique for phase encoding reduction. All experiments were carried out on three Tesla scanners (Siemens, TIM, and Germany equipped with 12 channel head coil. Ten subjects participated in the experiments. Results The data were processed by FSL software and were evaluated by ANOVA. Distortion was assessed by obtaining low displacement voxels map, and calculated from a field map image. Conclusion We showed that image distortion can be reduced by decreasing slice thickness and phase encoding steps. Distortion reduction in zoomed technique resulted the lowest level, but at the cost of signal-to-noise loss. Moreover, the SENSE technique was shown to decrease the amount of image distortion, efficiently.

  5. Geometrical E-beam proximity correction for raster scan systems

    Science.gov (United States)

    Belic, Nikola; Eisenmann, Hans; Hartmann, Hans; Waas, Thomas

    1999-04-01

    High pattern fidelity is a basic requirement for the generation of masks containing sub micro structures and for direct writing. Increasing needs mainly emerging from OPC at mask level and x-ray lithography require a correction of the e-beam proximity effect. The most part of e-beam writers are raster scan system. This paper describes a new method for geometrical pattern correction in order to provide a correction solution for e-beam system that are not able to apply variable doses.

  6. Self-consistent EXAFS PDF Projection Method by Matched Correction of Fourier Filter Signal Distortion

    International Nuclear Information System (INIS)

    Lee, Jay Min; Yang, Dong-Seok

    2007-01-01

    Inverse problem solving computation was performed for solving PDF (pair distribution function) from simulated data EXAFS based on data FEFF. For a realistic comparison with experimental data, we chose a model of the first sub-shell Mn-0 pair showing the Jahn Teller distortion in crystalline LaMnO3. To restore the Fourier filtering signal distortion, involved in the first sub-shell information isolated from higher shell contents, relevant distortion matching function was computed initially from the proximity model, and iteratively from the prior-guess during consecutive regularization computation. Adaptive computation of EXAFS background correction is an issue of algorithm development, but our preliminary test was performed under the simulated background correction perfectly excluding the higher shell interference. In our numerical result, efficient convergence of iterative solution indicates a self-consistent tendency that a true PDF solution is convinced as a counterpart of genuine chi-data, provided that a background correction function is iteratively solved using an extended algorithm of MEPP (Matched EXAFS PDF Projection) under development

  7. Internal process: what is abstraction and distortion process?

    Science.gov (United States)

    Fiantika, F. R.; Budayasa, I. K.; Lukito, A.

    2018-03-01

    Geometry is one of the branch of mathematics that plays a major role in the development of science and technology. Thus, knowing the geometry concept is needed for students from their early basic level of thinking. A preliminary study showed that the elementary students have difficulty in perceiving parallelogram shape in a 2-dimention of a cube drawing as a square shape. This difficulty makes the students can not solve geometrical problems correctly. This problem is related to the internal thinking process in geometry. We conducted the exploration of students’ internal thinking processes in geometry particularly in distinguishing the square and parallelogram shape. How the students process their internal thinking through distortion and abstraction is the main aim of this study. Analysis of the geometrical test and deep interview are used in this study to obtain the data. The result of this study is there are two types of distortion and abstraction respectively in which the student used in their internal thinking processes.

  8. Characterization of system-related geometric distortions in MR images employed in Gamma Knife radiosurgery applications

    Science.gov (United States)

    Pappas, E. P.; Seimenis, I.; Moutsatsos, A.; Georgiou, E.; Nomikos, P.; Karaiskos, P.

    2016-10-01

    This work provides characterization of system-related geometric distortions present in MRIs used in Gamma Knife (GK) stereotactic radiosurgery (SRS) treatment planning. A custom-made phantom, compatible with the Leksell stereotactic frame model G and encompassing 947 control points (CPs), was utilized. MR images were obtained with and without the frame, thus allowing discrimination of frame-induced distortions. In the absence of the frame and following compensation for field inhomogeneities, measured average CP disposition owing to gradient nonlinearities was 0.53 mm. In presence of the frame, contrarily, detected distortion was greatly increased (up to about 5 mm) in the vicinity of the frame base due to eddy currents induced in the closed loop of its aluminum material. Frame-related distortion was obliterated at approximately 90 mm from the frame base. Although the region with the maximum observed distortion may not lie within the GK treatable volume, the presence of the frame results in distortion of the order of 1.5 mm at a 7 cm distance from the center of the Leksell space. Additionally, severe distortions observed outside the treatable volume could possibly impinge on the delivery accuracy mainly by adversely affecting the registration process (e.g. the position of the lower part of the N-shaped fiducials used to define the stereotactic space may be miss-registered). Images acquired with a modified version of the frame developed by replacing its front side with an acrylic bar, thus interrupting the closed aluminum loop and reducing the induced eddy currents, were shown to benefit from relatively reduced distortion. System-related distortion was also identified in patient MR images. Using corresponding CT angiography images as a reference, an offset of 1.1 mm was detected for two vessels lying in close proximity to the frame base, while excellent spatial agreement was observed for a vessel far apart from the frame base.

  9. A distortion correction method for image intensifier and electronic portal images used in radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Ioannidis, G T; Geramani, K N; Zamboglou, N [Strahlenklinik, Stadtische Kliniken Offenbach, Offenbach (Germany); Uzunoglu, N [Department of Electrical and Computer Engineering, National Technical University of Athens, Athens (Greece)

    1999-12-31

    At the most of radiation departments a simulator and an `on line` verification system of the treated volume, in form of an electronic portal imaging device (EPID), are available. Networking and digital handling (saving, archiving etc.) of the image information is a necessity in the image processing procedures in order to evaluate verification and simulation recordings at the computer screen. Distortion is on the other hand prerequisite for quantitative comparison of both image modalities. Another limitation factor, in order to make quantitative assertions, is the fact that the irradiation fields in radiotherapy are usually bigger than the field of view of an image intensifier. Several segments of the irradiation field must therefore be acquired. Using pattern recognition techniques these segments can be composed into a single image. In this paper a distortion correction method will be presented. The method is based upon a well defined Grid which is embedded during the registration process on the image. The video signal from the image intensifier is acquired and processed. The grid is then recognised using image processing techniques. Ideally if all grid points are recognised, various methods can be applied in order to correct the distortion. But in practice this is not the case. Overlapping structures (bones etc.) have as a consequence that not all of the grid points can be recognised. Mathematical models from the Graph theory are applied in order to reconstruct the whole grid. The deviation of the grid points positions from the rated value is then used to calculate correction coefficients. This method (well defined grid, grid recognition, correction factors) can also be applied in verification images from the EPID or in other image modalities, and therefore a quantitative comparison in radiation treatment is possible. The distortion correction method and the application on simulator images will be presented. (authors)

  10. Correction of projective distortion in long-image-sequence mosaics without prior information

    Science.gov (United States)

    Yang, Chenhui; Mao, Hongwei; Abousleman, Glen; Si, Jennie

    2010-04-01

    Image mosaicking is the process of piecing together multiple video frames or still images from a moving camera to form a wide-area or panoramic view of the scene being imaged. Mosaics have widespread applications in many areas such as security surveillance, remote sensing, geographical exploration, agricultural field surveillance, virtual reality, digital video, and medical image analysis, among others. When mosaicking a large number of still images or video frames, the quality of the resulting mosaic is compromised by projective distortion. That is, during the mosaicking process, the image frames that are transformed and pasted to the mosaic become significantly scaled down and appear out of proportion with respect to the mosaic. As more frames continue to be transformed, important target information in the frames can be lost since the transformed frames become too small, which eventually leads to the inability to continue further. Some projective distortion correction techniques make use of prior information such as GPS information embedded within the image, or camera internal and external parameters. Alternatively, this paper proposes a new algorithm to reduce the projective distortion without using any prior information whatsoever. Based on the analysis of the projective distortion, we approximate the projective matrix that describes the transformation between image frames using an affine model. Using singular value decomposition, we can deduce the affine model scaling factor that is usually very close to 1. By resetting the image scale of the affine model to 1, the transformed image size remains unchanged. Even though the proposed correction introduces some error in the image matching, this error is typically acceptable and more importantly, the final mosaic preserves the original image size after transformation. We demonstrate the effectiveness of this new correction algorithm on two real-world unmanned air vehicle (UAV) sequences. The proposed method is

  11. EFFECTS OF X-RAY BEAM ANGLE AND GEOMETRIC DISTORTION ON WIDTH OF EQUINE THORACOLUMBAR INTERSPINOUS SPACES USING RADIOGRAPHY AND COMPUTED TOMOGRAPHY

    DEFF Research Database (Denmark)

    Djernaes, Julie D.; Nielsen, Jon V.; Berg, Lise C.

    2017-01-01

    The widths of spaces between the thoracolumbar processi spinosi (interspinous spaces) are frequently assessed using radiography in sports horses; however effects of varying X-ray beam angles and geometric distortion have not been previously described. The aim of this prospective, observational...... study was to determine whether X-ray beam angle has an effect on apparent widths of interspinous spaces. Thoracolumbar spine specimens were collected from six equine cadavers and left-right lateral radiographs and sagittal and dorsal reconstructed computed tomographic (CT) images were acquired...... measurements. Effect of geometric distortion was evaluated by comparing the interspinous space in radiographs with sagittal and dorsal reconstructed CT images. A total of 49 interspinous spaces were sampled, yielding 274 measurements. X-ray beam angle significantly affected measured width of interspinous...

  12. Distortion Correction for a Brewster Angle Microscope Using an Optical Grating.

    Science.gov (United States)

    Sun, Zhe; Zheng, Desheng; Baldelli, Steven

    2017-02-21

    A distortion-corrected Brewster angle microscope (DC-BAM) is designed, constructed, and tested based on the combination of an optical grating and a relay lens. Avoiding the drawbacks of most conventional BAM instruments, this configuration corrects the image propagation direction and consequently provides an image in focus over the entire field of view without any beam scanning or imaging reconstruction. This new BAM can be applied to both liquid and solid subphases with good spatial resolution in static and dynamic studies.

  13. IMPROVING GALACTIC CENTER ASTROMETRY BY REDUCING THE EFFECTS OF GEOMETRIC DISTORTION

    International Nuclear Information System (INIS)

    Yelda, S.; Ghez, A. M.; Clarkson, W.; Lu, J. R.; Matthews, K.; Anderson, J.; Do, T.

    2010-01-01

    We present significantly improved proper motion measurements of the Milky Way's central stellar cluster. These improvements are made possible by refining our astrometric reference frame with a new geometric optical distortion model for the W. M. Keck II 10 m telescope's adaptive optics camera (NIRC2) in its narrow field mode. For the first time, this distortion model is constructed from on-sky measurements and is made available to the public in the form of FITS files. When applied to widely dithered images, it produces residuals in the separations of stars that are a factor of ∼3 smaller compared with the outcome using previous models. By applying this new model, along with corrections for differential atmospheric refraction, to widely dithered images of SiO masers at the Galactic center (GC), we improve our ability to tie into the precisely measured radio Sgr A*-rest frame. The resulting infrared reference frame is ∼2-3 times more accurate and stable than earlier published efforts. In this reference frame, Sgr A* is localized to within a position of 0.6 mas and a velocity of 0.09 mas yr -1 , or ∼3.4 km s -1 at 8 kpc (1σ). Also, proper motions for members of the central stellar cluster are more accurate, although less precise, due to the limited number of these wide field measurements. These proper motion measurements show that, with respect to Sgr A*, the central stellar cluster has no rotation in the plane of the sky to within 0.3 mas yr -1 arcsec -1 , has no net translational motion with respect to Sgr A* to within 0.1 mas yr -1 , and has net rotation perpendicular to the plane of the sky along the Galactic plane, as has previously been observed. While earlier proper motion studies defined a reference frame by assuming no net motion of the stellar cluster, this approach is fundamentally limited by the cluster's intrinsic dispersion and therefore will not improve with time. We define a reference frame with SiO masers and this reference frame's stability

  14. The Need for Accurate Geometric and Radiometric Corrections of Drone-Borne Hyperspectral Data for Mineral Exploration: MEPHySTo—A Toolbox for Pre-Processing Drone-Borne Hyperspectral Data

    Directory of Open Access Journals (Sweden)

    Sandra Jakob

    2017-01-01

    Full Text Available Drone-borne hyperspectral imaging is a new and promising technique for fast and precise acquisition, as well as delivery of high-resolution hyperspectral data to a large variety of end-users. Drones can overcome the scale gap between field and air-borne remote sensing, thus providing high-resolution and multi-temporal data. They are easy to use, flexible and deliver data within cm-scale resolution. So far, however, drone-borne imagery has prominently and successfully been almost solely used in precision agriculture and photogrammetry. Drone technology currently mainly relies on structure-from-motion photogrammetry, aerial photography and agricultural monitoring. Recently, a few hyperspectral sensors became available for drones, but complex geometric and radiometric effects complicate their use for geology-related studies. Using two examples, we first show that precise corrections are required for any geological mapping. We then present a processing toolbox for frame-based hyperspectral imaging systems adapted for the complex correction of drone-borne hyperspectral imagery. The toolbox performs sensor- and platform-specific geometric distortion corrections. Furthermore, a topographic correction step is implemented to correct for rough terrain surfaces. We recommend the c-factor-algorithm for geological applications. To our knowledge, we demonstrate for the first time the applicability of the corrected dataset for lithological mapping and mineral exploration.

  15. Continuous table acquisition MRI for radiotherapy treatment planning: Distortion assessment with a new extended 3D volumetric phantom

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Amy, E-mail: aw554@uowmail.edu.au; Metcalfe, Peter [Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522, Australia and Liverpool and Macarthur Cancer Therapy Centres and Ingham Institute for Applied Medical Research, Liverpool, NSW 2170 (Australia); Liney, Gary [Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia); Liverpool and Macarthur Cancer Therapy Centres and Ingham Institute for Applied Medical Research, Liverpool, NSW 2170 (Australia); South West Clinical School, University of New South Wales, Sydney, NSW 2170 (Australia); Holloway, Lois [Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia); Liverpool and Macarthur Cancer Therapy Centres and Ingham Institute for Applied Medical Research, Liverpool, NSW 2170 (Australia); South West Clinical School, University of New South Wales, Sydney, NSW 2170 (Australia); Institute of Medical Physics, School of Physics, University of Sydney, Sydney, NSW 2006 (Australia); Dowling, Jason; Rivest-Henault, David [Commonwealth Scientific and Industrial Research Organisation, Australian E-Health Research Centre, Herston, QLD 4029 (Australia)

    2015-04-15

    Purpose: Accurate geometry is required for radiotherapy treatment planning (RTP). When considering the use of magnetic resonance imaging (MRI) for RTP, geometric distortions observed in the acquired images should be considered. While scanner technology and vendor supplied correction algorithms provide some correction, large distortions are still present in images, even when considering considerably smaller scan lengths than those typically acquired with CT in conventional RTP. This study investigates MRI acquisition with a moving table compared with static scans for potential geometric benefits for RTP. Methods: A full field of view (FOV) phantom (diameter 500 mm; length 513 mm) was developed for measuring geometric distortions in MR images over volumes pertinent to RTP. The phantom consisted of layers of refined plastic within which vitamin E capsules were inserted. The phantom was scanned on CT to provide the geometric gold standard and on MRI, with differences in capsule location determining the distortion. MRI images were acquired with two techniques. For the first method, standard static table acquisitions were considered. Both 2D and 3D acquisition techniques were investigated. With the second technique, images were acquired with a moving table. The same sequence was acquired with a static table and then with table speeds of 1.1 mm/s and 2 mm/s. All of the MR images acquired were registered to the CT dataset using a deformable B-spline registration with the resulting deformation fields providing the distortion information for each acquisition. Results: MR images acquired with the moving table enabled imaging of the whole phantom length while images acquired with a static table were only able to image 50%–70% of the phantom length of 513 mm. Maximum distortion values were reduced across a larger volume when imaging with a moving table. Increased table speed resulted in a larger contribution of distortion from gradient nonlinearities in the through

  16. Distortion correction for x-ray image intensifiers: Local unwarping polynomials and RBF neural networks

    International Nuclear Information System (INIS)

    Cerveri, P.; Forlani, C.; Borghese, N.A.; Ferrigno, G.

    2002-01-01

    In this paper we present two novel techniques, namely a local unwarping polynomial (LUP) and a hierarchical radial basis function (HRBF) network, to correct geometric distortions in XRII images. The two techniques have been implemented and compared, in terms of residual error measured at control and intermediate points, with local and global methods reported in the previous literature. In particular, LUP rests on a locally optimized 3rd degree polynomial applied within each quadrilateral cell on the rectilinear calibration grid of points. HRBF, based on a feed-forward neural network paradigm, is constituted by a set of hierarchical layers at increasing cut-off frequency, each characterized by a set of Gaussian functions. Extensive experiments have been performed both on simulated and real data. In simulation, we tested the effect of pincushion, sigmoidal and local distortions, along with the number of calibration points. Provided that a sufficient number of cells of the calibration grid is available, the obtained accuracy for both LUP and HRBF is comparable to or better than that of global polynomial technique. Tests on real data, carried out by using two different (12 in. and 16 in.) XRIIs, showed that the global polynomial accuracy (0.16±0.08 pixels) is slightly worse than that of LUP (0.07±0.05 pixels) and HRBF (0.08±0.04 pixels). The effects of the discontinuity at the border of the local areas and the decreased accuracy at intermediate points, typical of local techniques, have been proved to be smoothed for both LUP and HRBF

  17. The effect of the observer vantage point on perceived distortions in linear perspective images.

    Science.gov (United States)

    Todorović, Dejan

    2009-01-01

    Some features of linear perspective images may look distorted. Such distortions appear in two drawings by Jan Vredeman de Vries involving perceived elliptical, instead of circular, pillars and tilted, instead of upright, columns. Distortions may be due to factors intrinsic to the images, such as violations of the so-called Perkins's laws, or factors extrinsic to them, such as observing the images from positions different from their center of projection. When the correct projection centers for the two drawings were reconstructed, it was found that they were very close to the images and, therefore, practically unattainable in normal observation. In two experiments, enlarged versions of images were used as stimuli, making the positions of the projection centers attainable for observers. When observed from the correct positions, the perceived distortions disappeared or were greatly diminished. Distortions perceived from other positions were smaller than would be predicted by geometrical analyses, possibly due to flatness cues in the images. The results are relevant for the practical purposes of creating faithful impressions of 3-D spaces using 2-D images.

  18. Prospective analysis of in vivo landmark point-based MRI geometric distortion in head and neck cancer patients scanned in immobilized radiation treatment position: Results of a prospective quality assurance protocol

    Directory of Open Access Journals (Sweden)

    Abdallah S.R. Mohamed

    2017-12-01

    Full Text Available Purpose: Uncertainties related to geometric distortion are a major obstacle for effectively utilizing MRI in radiation oncology. We aim to quantify the geometric distortion in patient images by comparing their in-treatment position MRIs with the corresponding planning CTs, using CT as the non-distorted gold standard. Methods: Twenty-one head and neck cancer patients were imaged with MRI as part of a prospective Institutional Review Board approved study. MR images were acquired with a T2 SE sequence (0.5 × 0.5 × 2.5 mm voxel size in the same immobilization position as in the CTs. MRI to CT rigid registration was then done and geometric distortion comparison was assessed by measuring the corresponding anatomical landmarks on both the MRI and the CT images. Several landmark measurements were obtained including; skin to skin (STS, bone to bone, and soft tissue to soft tissue at specific levels in horizontal and vertical planes of both scans. Inter-observer variability was assessed and interclass correlation (ICC was calculated. Results: A total of 430 landmark measurements were obtained. The median distortion for all landmarks in all scans was 1.06 mm (IQR 0.6–1.98. For each patient 48% of the measurements were done in the right-left direction and 52% were done in the anteroposterior direction. The measured geometric distortion was not statistically different in the right-left direction compared to the anteroposterior direction (1.5 ± 1.6 vs. 1.6 ± 1.7 mm, respectively, p = 0.4. The magnitude of distortion was higher in the STS peripheral landmarks compared to the more central landmarks (2.0 ± 1.9 vs. 1.2 ± 1.3 mm, p < 0.0001. The mean distortion measured by observer one was not significantly different compared to observer 2, 3, and 4 (1.05, 1.23, 1.06 and 1.05 mm, respectively, p = 0.4 with ICC = 0.84. Conclusion: MRI geometric distortions were

  19. Correction of distortions in a discontinuous image

    International Nuclear Information System (INIS)

    Geagan, M.J.; Chase, B.B.; Muehllehner, G.

    1994-01-01

    Large area position-sensitive NaI detectors have been successfully applied to positron emission tomography (PET). Typical PET studies involve detector singles rates in excess of 500 kcps, which can lead to pile-up and image degradation as a function of countrate. Better high countrate performance can be achieved with a local centroid algorithm, in which the position of each event is calculated from a small group of photomultipliers (PMTs) immediately surrounding the PMT with the highest signal (the peak PMT). The local centroid contains most of the light from the scintillation. If a local centroid of only seven PMTs is used, the position resolution becomes quite stable at high countrates, however, discontinuities appear in the detector flood image as events cluster around each PMT. We therefore developed a method for distortion correction of a discontinuous flood image. For each PMT on the detector, a peak PMT domain is defined. The peak PMT domain is the area on the detector where that PMT could have the highest signal. The peak PMT domains overlap slightly, so that all combinations of peak PMT and position are represented. A collimated source is moved through a regular grid of points - a template - over each peak PMT region. A short collection is performed at each point, and the real and measured position data are recorded. For each point in the spatial range of a given PMT, distortion correction offsets are computed by interpolating between the data points which correspond to that PMT. This new method has been implemented and evaluated. System resolution has been measured at low and high countrates. The high countrate resolution is better with the new method, with no degradation in low countrate resolution. The axial sensitivity profile is also more stable at high countrates, compared to the previously developed method. 3-D brain phantom images show a clear improvement in image quality at high countrates. ((orig.))

  20. Geometric correction of radiographic images using general purpose image processing program

    International Nuclear Information System (INIS)

    Kim, Eun Kyung; Cheong, Ji Seong; Lee, Sang Hoon

    1994-01-01

    The present study was undertaken to compare geometric corrected image by general-purpose image processing program for the Apple Macintosh II computer (NIH Image, Adobe Photoshop) with standardized image by individualized custom fabricated alignment instrument. Two non-standardized periapical films with XCP film holder only were taken at the lower molar portion of 19 volunteers. Two standardized periapical films with customized XCP film holder with impression material on the bite-block were taken for each person. Geometric correction was performed with Adobe Photoshop and NIH Image program. Specially, arbitrary image rotation function of 'Adobe Photoshop' and subtraction with transparency function of 'NIH Image' were utilized. The standard deviations of grey values of subtracted images were used to measure image similarity. Average standard deviation of grey values of subtracted images if standardized group was slightly lower than that of corrected group. However, the difference was found to be statistically insignificant (p>0.05). It is considered that we can use 'NIH Image' and 'Adobe Photoshop' program for correction of nonstandardized film, taken with XCP film holder at lower molar portion.

  1. Research and implementation of the algorithm for unwrapped and distortion correction basing on CORDIC for panoramic image

    Science.gov (United States)

    Zhang, Zhenhai; Li, Kejie; Wu, Xiaobing; Zhang, Shujiang

    2008-03-01

    The unwrapped and correcting algorithm based on Coordinate Rotation Digital Computer (CORDIC) and bilinear interpolation algorithm was presented in this paper, with the purpose of processing dynamic panoramic annular image. An original annular panoramic image captured by panoramic annular lens (PAL) can be unwrapped and corrected to conventional rectangular image without distortion, which is much more coincident with people's vision. The algorithm for panoramic image processing is modeled by VHDL and implemented in FPGA. The experimental results show that the proposed panoramic image algorithm for unwrapped and distortion correction has the lower computation complexity and the architecture for dynamic panoramic image processing has lower hardware cost and power consumption. And the proposed algorithm is valid.

  2. Correction of rotational distortion for catheter-based en face OCT and OCT angiography

    Science.gov (United States)

    Ahsen, Osman O.; Lee, Hsiang-Chieh; Giacomelli, Michael G.; Wang, Zhao; Liang, Kaicheng; Tsai, Tsung-Han; Potsaid, Benjamin; Mashimo, Hiroshi; Fujimoto, James G.

    2015-01-01

    We demonstrate a computationally efficient method for correcting the nonuniform rotational distortion (NURD) in catheter-based imaging systems to improve endoscopic en face optical coherence tomography (OCT) and OCT angiography. The method performs nonrigid registration using fiducial markers on the catheter to correct rotational speed variations. Algorithm performance is investigated with an ultrahigh-speed endoscopic OCT system and micromotor catheter. Scan nonuniformity is quantitatively characterized, and artifacts from rotational speed variations are significantly reduced. Furthermore, we present endoscopic en face OCT and OCT angiography images of human gastrointestinal tract in vivo to demonstrate the image quality improvement using the correction algorithm. PMID:25361133

  3. MRI simulation: end-to-end testing for prostate radiation therapy using geometric pelvic MRI phantoms

    International Nuclear Information System (INIS)

    Sun, Jidi; Menk, Fred; Lambert, Jonathan; Martin, Jarad; Denham, James W; Greer, Peter B; Dowling, Jason; Rivest-Henault, David; Pichler, Peter; Parker, Joel; Arm, Jameen; Best, Leah

    2015-01-01

    To clinically implement MRI simulation or MRI-alone treatment planning requires comprehensive end-to-end testing to ensure an accurate process. The purpose of this study was to design and build a geometric phantom simulating a human male pelvis that is suitable for both CT and MRI scanning and use it to test geometric and dosimetric aspects of MRI simulation including treatment planning and digitally reconstructed radiograph (DRR) generation.A liquid filled pelvic shaped phantom with simulated pelvic organs was scanned in a 3T MRI simulator with dedicated radiotherapy couch-top, laser bridge and pelvic coil mounts. A second phantom with the same external shape but with an internal distortion grid was used to quantify the distortion of the MR image. Both phantoms were also CT scanned as the gold-standard for both geometry and dosimetry. Deformable image registration was used to quantify the MR distortion. Dose comparison was made using a seven-field IMRT plan developed on the CT scan with the fluences copied to the MR image and recalculated using bulk electron densities.Without correction the maximum distortion of the MR compared with the CT scan was 7.5 mm across the pelvis, while this was reduced to 2.6 and 1.7 mm by the vendor’s 2D and 3D correction algorithms, respectively. Within the locations of the internal organs of interest, the distortion was <1.5 and <1 mm with 2D and 3D correction algorithms, respectively. The dose at the prostate isocentre calculated on CT and MRI images differed by 0.01% (1.1 cGy). Positioning shifts were within 1 mm when setup was performed using MRI generated DRRs compared to setup using CT DRRs.The MRI pelvic phantom allows end-to-end testing of the MRI simulation workflow with comparison to the gold-standard CT based process. MRI simulation was found to be geometrically accurate with organ dimensions, dose distributions and DRR based setup within acceptable limits compared to CT. (paper)

  4. Numerical correction of distorted images in full-field optical coherence tomography

    Science.gov (United States)

    Min, Gihyeon; Kim, Ju Wan; Choi, Woo June; Lee, Byeong Ha

    2012-03-01

    We propose a numerical method which can numerically correct the distorted en face images obtained with a full field optical coherence tomography (FF-OCT) system. It is shown that the FF-OCT image of the deep region of a biological sample is easily blurred or degraded because the sample has a refractive index (RI) much higher than its surrounding medium in general. It is analyzed that the focal plane of the imaging system is segregated from the imaging plane of the coherence-gated system due to the RI mismatch. This image-blurring phenomenon is experimentally confirmed by imaging the chrome pattern of a resolution test target through its glass substrate in water. Moreover, we demonstrate that the blurred image can be appreciably corrected by using the numerical correction process based on the Fresnel-Kirchhoff diffraction theory. The proposed correction method is applied to enhance the image of a human hair, which permits the distinct identification of the melanin granules inside the cortex layer of the hair shaft.

  5. Correction method and software for image distortion and nonuniform response in charge-coupled device-based x-ray detectors utilizing x-ray image intensifier

    International Nuclear Information System (INIS)

    Ito, Kazuki; Kamikubo, Hironari; Yagi, Naoto; Amemiya, Yoshiyuki

    2005-01-01

    An on-site method of correcting the image distortion and nonuniform response of a charge-coupled device (CCD)-based X-ray detector was developed using the response of the imaging plate as a reference. The CCD-based X-ray detector consists of a beryllium-windowed X-ray image intensifier (Be-XRII) and a CCD as the image sensor. An image distortion of 29% was improved to less than 1% after the correction. In the correction of nonuniform response due to image distortion, subpixel approximation was performed for the redistribution of pixel values. The optimal number of subpixels was also discussed. In an experiment with polystyrene (PS) latex, it was verified that the correction of both image distortion and nonuniform response worked properly. The correction for the 'contrast reduction' problem was also demonstrated for an isotropic X-ray scattering pattern from the PS latex. (author)

  6. The main postulates of adaptive correction of distortions of the wave front in large-size optical systems

    Directory of Open Access Journals (Sweden)

    V. V. Sychev

    2014-01-01

    medium on the transmitted radiation WF;•  the lack of a reference source at the wavelength of trasnmitted laser radiation, which is required to implement methods for adaptive correction of the distorted WF;•  the unique to laser systems additional distorting factors available in transmission systems.These distorting factors include:• length of the optical path due to need in spatial diversity of high power laser source with a large number of matching optical elements;• thermal self-action of power laser radiation in the transport path of the radiation before its entry into forming optical system;• instability of spatio-temporal characteristics of the laser radiation source itself to take a turn for the worse conditions of radiation transmission both inside the optical path, and in the free atmosphere;• thermal irregularities and thermal deformation.It is shown that the adaptive systems differ from the active optics in that radiation wave front distortion is corrected in real time per totality of distorting factors (not only on the effect of the atmosphere with the speed ten times exceeding the effect of distortion itself. Here, the correction quality is estimated by criterion of the primary image quality.In this case, the correction continuously takes into account data about optical system parameters such as current space, temperature, time, and adjusting, thereby supporting the high quality of images under the action of distorting factors.The paper formulates and proposes the basic postulates of adaptive correction.Postulates are a set of statements and assertions, allowing us to implement effective means of adaptive correction of distortions.The paper also shows the real capabilities the methods and means of adaptive optics offer in case of efficient use of laser radiation power and what ways are possible to solve these tasks. First of all, these are:- forming a system of assumptions and minimization of distortions in the optical path, which includes a

  7. Centi-pixel accurate real-time inverse distortion correction

    CSIR Research Space (South Africa)

    De Villiers, Johan P

    2008-11-01

    Full Text Available Inverse distortion is used to create an undistorted image from a distorted image. For each pixel in the undistorted image it is required to determine which pixel in the distorted image should be used. However the process of characterizing a lens...

  8. Visualization and spectral synthesis of rotationally distorted stars

    International Nuclear Information System (INIS)

    Dall, T H; Sbordone, L

    2011-01-01

    Simple spherical, non-rotating stellar models are inadequate when describing real stars in the limit of very fast rotation: Both the observable spectrum and the geometrical shape of the star deviate strongly from simple models. We attempt to approach the problem of modeling geometrically distorted, rapidly rotating stars from a new angle: By constructing distorted geometrical models and integrating standard stellar models with varying temperature, gravity, and abundances, over the entire surface, we attempt a semi-empirical approach to modeling. Here we present our methodology, and present simple examples of applications.

  9. Design and implementation of a 3D-MR/CT geometric image distortion phantom/analysis system for stereotactic radiosurgery

    Science.gov (United States)

    Damyanovich, A. Z.; Rieker, M.; Zhang, B.; Bissonnette, J.-P.; Jaffray, D. A.

    2018-04-01

    The design, construction and application of a multimodality, 3D magnetic resonance/computed tomography (MR/CT) image distortion phantom and analysis system for stereotactic radiosurgery (SRS) is presented. The phantom is characterized by (1) a 1 × 1 × 1 (cm)3 MRI/CT-visible 3D-Cartesian grid; (2) 2002 grid vertices that are 3D-intersections of MR-/CT-visible ‘lines’ in all three orthogonal planes; (3) a 3D-grid that is MR-signal positive/CT-signal negative; (4) a vertex distribution sufficiently ‘dense’ to characterize geometrical parameters properly, and (5) a grid/vertex resolution consistent with SRS localization accuracy. When positioned correctly, successive 3D-vertex planes along any orthogonal axis of the phantom appear as 1 × 1 (cm)2-2D grids, whereas between vertex planes, images are defined by 1 × 1 (cm)2-2D arrays of signal points. Image distortion is evaluated using a centroid algorithm that automatically identifies the center of each 3D-intersection and then calculates the deviations dx, dy, dz and dr for each vertex point; the results are presented as a color-coded 2D or 3D distribution of deviations. The phantom components and 3D-grid are machined to sub-millimeter accuracy, making the device uniquely suited to SRS applications; as such, we present it here in a form adapted for use with a Leksell stereotactic frame. Imaging reproducibility was assessed via repeated phantom imaging across ten back-to-back scans; 80%–90% of the differences in vertex deviations dx, dy, dz and dr between successive 3 T MRI scans were found to be  ⩽0.05 mm for both axial and coronal acquisitions, and over  >95% of the differences were observed to be  ⩽0.05 mm for repeated CT scans, clearly demonstrating excellent reproducibility. Applications of the 3D-phantom/analysis system are presented, using a 32-month time-course assessment of image distortion/gradient stability and statistical control chart for 1.5 T and 3 T GE TwinSpeed MRI

  10. One step geometrical calibration method for optical coherence tomography

    International Nuclear Information System (INIS)

    Díaz, Jesús Díaz; Ortmaier, Tobias; Stritzel, Jenny; Rahlves, Maik; Reithmeier, Eduard; Roth, Bernhard; Majdani, Omid

    2016-01-01

    We present a novel one-step calibration methodology for geometrical distortion correction for optical coherence tomography (OCT). A calibration standard especially designed for OCT is introduced, which consists of an array of inverse pyramidal structures. The use of multiple landmarks situated on four different height levels on the pyramids allow performing a 3D geometrical calibration. The calibration procedure itself is based on a parametric model of the OCT beam propagation. It is validated by experimental results and enables the reduction of systematic errors by more than one order of magnitude. In future, our results can improve OCT image reconstruction and interpretation for medical applications such as real time monitoring of surgery. (paper)

  11. Hydrodynamic Limit with Geometric Correction of Stationary Boltzmann Equation

    OpenAIRE

    Wu, Lei

    2014-01-01

    We consider the hydrodynamic limit of a stationary Boltzmann equation in a unit plate with in-flow boundary. We prove the solution can be approximated in $L^{\\infty}$ by the sum of interior solution which satisfies steady incompressible Navier-Stokes-Fourier system, and boundary layer with geometric correction. Also, we construct a counterexample to the classical theory which states the behavior of solution near boundary can be described by the Knudsen layer derived from the Milne problem.

  12. SU-G-JeP2-13: Spatial Accuracy Evaluation for Real-Time MR Guided Radiation Therapy Using a Novel Large-Field MRI Distortion Phantom

    International Nuclear Information System (INIS)

    Antolak, A; Bayouth, J; Bosca, R; Jackson, E

    2016-01-01

    Purpose: Evaluate a large-field MRI phantom for assessment of geometric distortion in whole-body MRI for real-time MR guided radiation therapy. Methods: A prototype CIRS large-field MRI distortion phantom consisting of a PMMA cylinder (33 cm diameter, 30 cm length) containing a 3D-printed orthogonal grid (3 mm diameter rods, 20 mm apart), was filled with 6 mM NiCl_2 and 30 mM NaCl solution. The phantom was scanned at 1.5T and 3.0T on a GE HDxt and Discovery MR750, respectively, and at 0.35T on a ViewRay system. Scans were obtained with and without 3D distortion correction to demonstrate the impact of such corrections. CT images were used as a reference standard for analysis of geometric distortion, as determined by a fully automated gradient-search method developed in Matlab. Results: 1,116 grid points distributed throughout a cylindrical volume 28 cm in diameter and 16 cm in length were identified and analyzed. With 3D distortion correction, average/maximum displacements for the 1.5, 3.0, and 0.35T systems were 0.84/2.91, 1.00/2.97, and 0.95/2.37 mm, respectively. The percentage of points with less than (1.0, 1.5, 2.0 mm) total displacement were (73%, 92%, 97%), (54%, 85%, 97%), and (55%, 90%, 99%), respectively. A reduced scan volume of 20 × 20 × 10 cm"3 (representative of a head and neck scan volume) consisting of 420 points was also analyzed. In this volume, the percentage of points with less than (1.0, 1.5, 2.0 mm) total displacement were (90%, 99%, 100%), (63%, 95%, 100%), and (75%, 96%, 100%), respectively. Without 3D distortion correction, average/maximum displacements were 1.35/3.67, 1.67/4.46, and 1.51/3.89 mm, respectively. Conclusion: The prototype large-field MRI distortion phantom and developed software provide a thorough assessment of 3D spatial distortions in MRI. The distortions measured were acceptable for RT applications, both for the high field strengths and the system configuration developed by ViewRay.

  13. Geometric Calibration and Radiometric Correction of LiDAR Data and Their Impact on the Quality of Derived Products

    Directory of Open Access Journals (Sweden)

    Wai-Yeung Yan

    2011-09-01

    Full Text Available LiDAR (Light Detection And Ranging systems are capable of providing 3D positional and spectral information (in the utilized spectrum range of the mapped surface. Due to systematic errors in the system parameters and measurements, LiDAR systems require geometric calibration and radiometric correction of the intensity data in order to maximize the benefit from the collected positional and spectral information. This paper presents a practical approach for the geometric calibration of LiDAR systems and radiometric correction of collected intensity data while investigating their impact on the quality of the derived products. The proposed approach includes the use of a quasi-rigorous geometric calibration and the radar equation for the radiometric correction of intensity data. The proposed quasi-rigorous calibration procedure requires time-tagged point cloud and trajectory position data, which are available to most of the data users. The paper presents a methodology for evaluating the impact of the geometric calibration on the relative and absolute accuracy of the LiDAR point cloud. Furthermore, the impact of the geometric calibration and radiometric correction on land cover classification accuracy is investigated. The feasibility of the proposed methods and their impact on the derived products are demonstrated through experimental results using real data.

  14. TPC track distortions IV: post tenebras lux

    CERN Document Server

    Ammosov, V; Boyko, I; Chelkov, G; Dedovitch, D; Dydak, F; Elagin, A; Gostkin, M; Guskov, A; Koreshev, V; Krumshtein, Z; Nefedov, Y; Nikolaev, K; Wotschack, J; Zhemchugov, A

    2007-01-01

    We present a comprehensive discussion and summary of static and dynamic track distortions in the HARP TPC in terms of physical origin, mathematical modelling and correction algorithms. `Static' distortions are constant with time, while `dynamic' distortions are distortions that occur only during the 400 ms long accelerator spill. The measurement of dynamic distortions, their mathematical modelling and the correction algorithms build on our understanding of static distortions. In the course of corroborating the validity of our static distortion corrections, their reliability and precision was further improved. Dynamic TPC distortions originate dominantly from the `stalactite' effect: a column of positive-ion charge starts growing at the begin of the accelerator spill, and continues growing with nearly constant velocity out from the sense-wire plane into the active TPC volume. However, the `stalactite' effect is not able to describe the distortions that are present already at the start of the spill and which ha...

  15. TU-H-206-01: An Automated Approach for Identifying Geometric Distortions in Gamma Cameras

    Energy Technology Data Exchange (ETDEWEB)

    Mann, S; Nelson, J [Clinical Imaging Physics Group and Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Samei, E [Clinical Imaging Physics Group and Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 and Departments of Physics, Electrical and Computer Engineering, and Biomedical Engineering, and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States)

    2016-06-15

    Purpose: To develop a clinically-deployable, automated process for detecting artifacts in routine nuclear medicine (NM) quality assurance (QA) bar phantom images. Methods: An artifact detection algorithm was created to analyze bar phantom images as part of an ongoing QA program. A low noise, high resolution reference image was acquired from an x-ray of the bar phantom with a Philips Digital Diagnost system utilizing image stitching. NM bar images, acquired for 5 million counts over a 512×512 matrix, were registered to the template image by maximizing mutual information (MI). The MI index was used as an initial test for artifacts; low values indicate an overall presence of distortions regardless of their spatial location. Images with low MI scores were further analyzed for bar linearity, periodicity, alignment, and compression to locate differences with respect to the template. Findings from each test were spatially correlated and locations failing multiple tests were flagged as potential artifacts requiring additional visual analysis. The algorithm was initially deployed for GE Discovery 670 and Infinia Hawkeye gamma cameras. Results: The algorithm successfully identified clinically relevant artifacts from both systems previously unnoticed by technologists performing the QA. Average MI indices for artifact-free images are 0.55. Images with MI indices < 0.50 have shown 100% sensitivity and specificity for artifact detection when compared with a thorough visual analysis. Correlation of geometric tests confirms the ability to spatially locate the most likely image regions containing an artifact regardless of initial phantom orientation. Conclusion: The algorithm shows the potential to detect gamma camera artifacts that may be missed by routine technologist inspections. Detection and subsequent correction of artifacts ensures maximum image quality and may help to identify failing hardware before it impacts clinical workflow. Going forward, the algorithm is being

  16. Invisible data matrix detection with smart phone using geometric correction and Hough transform

    Science.gov (United States)

    Sun, Halit; Uysalturk, Mahir C.; Karakaya, Mahmut

    2016-04-01

    Two-dimensional data matrices are used in many different areas that provide quick and automatic data entry to the computer system. Their most common usage is to automatically read labeled products (books, medicines, food, etc.) and recognize them. In Turkey, alcohol beverages and tobacco products are labeled and tracked with the invisible data matrices for public safety and tax purposes. In this application, since data matrixes are printed on a special paper with a pigmented ink, it cannot be seen under daylight. When red LEDs are utilized for illumination and reflected light is filtered, invisible data matrices become visible and decoded by special barcode readers. Owing to their physical dimensions, price and requirement of special training to use; cheap, small sized and easily carried domestic mobile invisible data matrix reader systems are required to be delivered to every inspector in the law enforcement units. In this paper, we first developed an apparatus attached to the smartphone including a red LED light and a high pass filter. Then, we promoted an algorithm to process captured images by smartphones and to decode all information stored in the invisible data matrix images. The proposed algorithm mainly involves four stages. In the first step, data matrix code is processed by Hough transform processing to find "L" shaped pattern. In the second step, borders of the data matrix are found by using the convex hull and corner detection methods. Afterwards, distortion of invisible data matrix corrected by geometric correction technique and the size of every module is fixed in rectangular shape. Finally, the invisible data matrix is scanned line by line in the horizontal axis to decode it. Based on the results obtained from the real test images of invisible data matrix captured with a smartphone, the proposed algorithm indicates high accuracy and low error rate.

  17. Distortion definition and correction in off-axis systems

    Science.gov (United States)

    Da Deppo, Vania; Simioni, Emanuele; Naletto, Giampiero; Cremonese, Gabriele

    2015-09-01

    Off-axis optical configurations are becoming more and more used in a variety of applications, in particular they are the most preferred solution for cameras devoted to Solar System planets and small bodies (i.e. asteroids and comets) study. Off-axis designs, being devoid of central obstruction, are able to guarantee better PSF and MTF performance, and thus higher contrast imaging capabilities with respect to classical on-axis designs. In particular they are suitable for observing extended targets with intrinsic low contrast features, or scenes where a high dynamical signal range is present. Classical distortion theory is able to well describe the performance of the on-axis systems, but it has to be adapted for the off-axis case. A proper way to deal with off-axis distortion definition is thus needed together with dedicated techniques to accurately measure and hence remove the distortion effects present in the acquired images. In this paper, a review of the distortion definition for off-axis systems will be given. In particular the method adopted by the authors to deal with the distortion related issues (definition, measure, removal) in some off-axis instruments will be described in detail.

  18. A Color Image Watermarking Scheme Resistant against Geometrical Attacks

    Directory of Open Access Journals (Sweden)

    Y. Xing

    2010-04-01

    Full Text Available The geometrical attacks are still a problem for many digital watermarking algorithms at present. In this paper, we propose a watermarking algorithm for color images resistant to geometrical distortions (rotation and scaling. The singular value decomposition is used for watermark embedding and extraction. The log-polar map- ping (LPM and phase correlation method are used to register the position of geometrical distortion suffered by the watermarked image. Experiments with different kinds of color images and watermarks demonstrate that the watermarking algorithm is robust to common image processing attacks, especially geometrical attacks.

  19. Geometric Calibration and Radiometric Correction of the Maia Multispectral Camera

    Science.gov (United States)

    Nocerino, E.; Dubbini, M.; Menna, F.; Remondino, F.; Gattelli, M.; Covi, D.

    2017-10-01

    Multispectral imaging is a widely used remote sensing technique, whose applications range from agriculture to environmental monitoring, from food quality check to cultural heritage diagnostic. A variety of multispectral imaging sensors are available on the market, many of them designed to be mounted on different platform, especially small drones. This work focuses on the geometric and radiometric characterization of a brand-new, lightweight, low-cost multispectral camera, called MAIA. The MAIA camera is equipped with nine sensors, allowing for the acquisition of images in the visible and near infrared parts of the electromagnetic spectrum. Two versions are available, characterised by different set of band-pass filters, inspired by the sensors mounted on the WorlView-2 and Sentinel2 satellites, respectively. The camera details and the developed procedures for the geometric calibrations and radiometric correction are presented in the paper.

  20. Comparing artistic and geometrical perspective depictions of space in the visual field.

    Science.gov (United States)

    Baldwin, Joseph; Burleigh, Alistair; Pepperell, Robert

    2014-01-01

    Which is the most accurate way to depict space in our visual field? Linear perspective, a form of geometrical perspective, has traditionally been regarded as the correct method of depicting visual space. But artists have often found it is limited in the angle of view it can depict; wide-angle scenes require uncomfortably close picture viewing distances or impractical degrees of enlargement to be seen properly. Other forms of geometrical perspective, such as fisheye projections, can represent wider views but typically produce pictures in which objects appear distorted. In this study we created an artistic rendering of a hemispherical visual space that encompassed the full visual field. We compared it to a number of geometrical perspective projections of the same space by asking participants to rate which best matched their visual experience. We found the artistic rendering performed significantly better than the geometrically generated projections.

  1. Correction of a Depth-Dependent Lateral Distortion in 3D Super-Resolution Imaging.

    Directory of Open Access Journals (Sweden)

    Lina Carlini

    Full Text Available Three-dimensional (3D localization-based super-resolution microscopy (SR requires correction of aberrations to accurately represent 3D structure. Here we show how a depth-dependent lateral shift in the apparent position of a fluorescent point source, which we term `wobble`, results in warped 3D SR images and provide a software tool to correct this distortion. This system-specific, lateral shift is typically > 80 nm across an axial range of ~ 1 μm. A theoretical analysis based on phase retrieval data from our microscope suggests that the wobble is caused by non-rotationally symmetric phase and amplitude aberrations in the microscope's pupil function. We then apply our correction to the bacterial cytoskeletal protein FtsZ in live bacteria and demonstrate that the corrected data more accurately represent the true shape of this vertically-oriented ring-like structure. We also include this correction method in a registration procedure for dual-color, 3D SR data and show that it improves target registration error (TRE at the axial limits over an imaging depth of 1 μm, yielding TRE values of < 20 nm. This work highlights the importance of correcting aberrations in 3D SR to achieve high fidelity between the measurements and the sample.

  2. A methodology to investigate the impact of image distortions on the radiation dose when using magnetic resonance images for planning

    Science.gov (United States)

    Yan, Yue; Yang, Jinzhong; Beddar, Sam; Ibbott, Geoffrey; Wen, Zhifei; Court, Laurence E.; Hwang, Ken-Pin; Kadbi, Mo; Krishnan, Sunil; Fuller, Clifton D.; Frank, Steven J.; Yang, James; Balter, Peter; Kudchadker, Rajat J.; Wang, Jihong

    2018-04-01

    We developed a novel technique to study the impact of geometric distortion of magnetic resonance imaging (MRI) on intensity-modulated radiation therapy treatment planning. The measured 3D datasets of residual geometric distortion (a 1.5 T MRI component of an MRI linear accelerator system) was fitted with a second-order polynomial model to map the spatial dependence of geometric distortions. Then the geometric distortion model was applied to computed tomography (CT) image and structure data to simulate the distortion of MRI data and structures. Fourteen CT-based treatment plans were selected from patients treated for gastrointestinal, genitourinary, thoracic, head and neck, or spinal tumors. Plans based on the distorted CT and structure data were generated (as the distorted plans). Dose deviations of the distorted plans were calculated and compared with the original plans to study the dosimetric impact of MRI distortion. The MRI geometric distortion led to notable dose deviations in five of the 14 patients, causing loss of target coverage of up to 3.68% and dose deviations to organs at risk in three patients, increasing the mean dose to the chest wall by up to 6.19 Gy in a gastrointestinal patient, and increases the maximum dose to the lung by 5.17 Gy in a thoracic patient.

  3. Doppler distortion correction based on microphone array and matching pursuit algorithm for a wayside train bearing monitoring system

    International Nuclear Information System (INIS)

    Liu, Xingchen; Hu, Zhiyong; He, Qingbo; Zhang, Shangbin; Zhu, Jun

    2017-01-01

    Doppler distortion and background noise can reduce the effectiveness of wayside acoustic train bearing monitoring and fault diagnosis. This paper proposes a method of combining a microphone array and matching pursuit algorithm to overcome these difficulties. First, a dictionary is constructed based on the characteristics and mechanism of a far-field assumption. Then, the angle of arrival of the train bearing is acquired when applying matching pursuit to analyze the acoustic array signals. Finally, after obtaining the resampling time series, the Doppler distortion can be corrected, which is convenient for further diagnostic work. Compared with traditional single-microphone Doppler correction methods, the advantages of the presented array method are its robustness to background noise and its barely requiring pre-measuring parameters. Simulation and experimental study show that the proposed method is effective in performing wayside acoustic bearing fault diagnosis. (paper)

  4. Doppler distortion correction based on microphone array and matching pursuit algorithm for a wayside train bearing monitoring system

    Science.gov (United States)

    Liu, Xingchen; Hu, Zhiyong; He, Qingbo; Zhang, Shangbin; Zhu, Jun

    2017-10-01

    Doppler distortion and background noise can reduce the effectiveness of wayside acoustic train bearing monitoring and fault diagnosis. This paper proposes a method of combining a microphone array and matching pursuit algorithm to overcome these difficulties. First, a dictionary is constructed based on the characteristics and mechanism of a far-field assumption. Then, the angle of arrival of the train bearing is acquired when applying matching pursuit to analyze the acoustic array signals. Finally, after obtaining the resampling time series, the Doppler distortion can be corrected, which is convenient for further diagnostic work. Compared with traditional single-microphone Doppler correction methods, the advantages of the presented array method are its robustness to background noise and its barely requiring pre-measuring parameters. Simulation and experimental study show that the proposed method is effective in performing wayside acoustic bearing fault diagnosis.

  5. METHOD OF RADIOMETRIC DISTORTION CORRECTION OF MULTISPECTRAL DATA FOR THE EARTH REMOTE SENSING

    Directory of Open Access Journals (Sweden)

    A. N. Grigoriev

    2015-07-01

    Full Text Available The paper deals with technologies of ground secondary processing of heterogeneous multispectral data. The factors of heterogeneous data include uneven illumination of objects on the Earth surface caused by different properties of the relief. A procedure for the image restoration of spectral channels by means of terrain distortion compensation is developed. The object matter of this paper is to improve the quality of the results during image restoration of areas with large and medium landforms. Methods. Researches are based on the elements of the digital image processing theory, statistical processing of the observation results and the theory of multi-dimensional arrays. Main Results. The author has introduced operations on multidimensional arrays: concatenation and elementwise division. Extended model description for input data about the area is given. The model contains all necessary data for image restoration. Correction method for multispectral data radiometric distortions of the Earth remote sensing has been developed. The method consists of two phases: construction of empirical dependences for spectral reflectance on the relief properties and restoration of spectral images according to semiempirical data. Practical Relevance. Research novelty lies in developme nt of the application theory of multidimensional arrays with respect to the processing of multispectral data, together with data on the topography and terrain objects. The results are usable for development of radiometric data correction tools. Processing is performed on the basis of a digital terrain model without carrying out ground works connected with research of the objects reflective properties.

  6. Generic distortion model for metrology under optical microscopes

    Science.gov (United States)

    Liu, Xingjian; Li, Zhongwei; Zhong, Kai; Chao, YuhJin; Miraldo, Pedro; Shi, Yusheng

    2018-04-01

    For metrology under optical microscopes, lens distortion is the dominant source of error. Previous distortion models and correction methods mostly rely on the assumption that parametric distortion models require a priori knowledge of the microscopes' lens systems. However, because of the numerous optical elements in a microscope, distortions can be hardly represented by a simple parametric model. In this paper, a generic distortion model considering both symmetric and asymmetric distortions is developed. Such a model is obtained by using radial basis functions (RBFs) to interpolate the radius and distortion values of symmetric distortions (image coordinates and distortion rays for asymmetric distortions). An accurate and easy to implement distortion correction method is presented. With the proposed approach, quantitative measurement with better accuracy can be achieved, such as in Digital Image Correlation for deformation measurement when used with an optical microscope. The proposed technique is verified by both synthetic and real data experiments.

  7. THE METHOD OF GEOMETRIC CALIBRATION OF OPTOELECTRONIC SYSTEMS BASED ON ELECTRONIC TEST OBJECT

    Directory of Open Access Journals (Sweden)

    D. A. Kozhevnikov

    2017-01-01

    Full Text Available Designing remote sensing of the Earth devices is requires a lot of attention to evaluation lens distortion level and providing the required accuracy values of geometric calibration of optoelectronic systems at all. Test- objects known as most common tools for optical systems geometric calibration. The purpose of the research was creating an automatically method of distortion correction coefficients calculating with a 3 μm precision in the measurement process. The method of geometric calibration of the internal orientation elements of the optical system based on the electronic test object is proposed. The calculation of the test string brightness image from its multispectral image and filtered signal extrema position determination are presented. Ratio of magnitude of the distortion and interval center is given. Three variants of electronic test-objects with different step and element size are considered. Оptimal size of calibration element was defined as 3×3 pixels due to shape of the subpixels with the aspect ratio of the radiating areas about 1 : 3. It is advisable to use IPS as an electronic test object template. An experimental test and measurement stand functional diagram based on the collimator and optical bench «OSK-2CL» is showed. It was determined that test objects with a grid spacing of 4 and 8 pixels can’t provide tolerable image because of non-collimated emission of active sites and scattering on optical surfaces – the shape of the elements is substantially disrupted. Test-object with a 12 pixels grid spacing was used to distortion level analyzing as most suitable.Ratio of coordinate increment and element number graphs for two photographic lenses (Canon EF-S 17-85 f/4-5.6 IS USM and EF-S 18-55 f/3.5-5.6 IS II are presented. A calculation of the distortion values in edge zones was held, which were respectively 43 μm and 51.6 μm. The technique and algorithm of software implementation is described. Possible directions of the

  8. A GENERALIZED NON-LINEAR METHOD FOR DISTORTION CORRECTION AND TOP-DOWN VIEW CONVERSION OF FISH EYE IMAGES

    Directory of Open Access Journals (Sweden)

    Vivek Singh Bawa

    2017-06-01

    Full Text Available Advanced driver assistance systems (ADAS have been developed to automate and modify vehicles for safety and better driving experience. Among all computer vision modules in ADAS, 360-degree surround view generation of immediate surroundings of the vehicle is very important, due to application in on-road traffic assistance, parking assistance etc. This paper presents a novel algorithm for fast and computationally efficient transformation of input fisheye images into required top down view. This paper also presents a generalized framework for generating top down view of images captured by cameras with fish-eye lenses mounted on vehicles, irrespective of pitch or tilt angle. The proposed approach comprises of two major steps, viz. correcting the fish-eye lens images to rectilinear images, and generating top-view perspective of the corrected images. The images captured by the fish-eye lens possess barrel distortion, for which a nonlinear and non-iterative method is used. Thereafter, homography is used to obtain top-down view of corrected images. This paper also targets to develop surroundings of the vehicle for wider distortion less field of view and camera perspective independent top down view, with minimum computation cost which is essential due to limited computation power on vehicles.

  9. Axial geometrical aberration correction up to 5th order with N-SYLC.

    Science.gov (United States)

    Hoque, Shahedul; Ito, Hiroyuki; Takaoka, Akio; Nishi, Ryuji

    2017-11-01

    We present N-SYLC (N-fold symmetric line currents) models to correct 5th order axial geometrical aberrations in electron microscopes. In our previous paper, we showed that 3rd order spherical aberration can be corrected by 3-SYLC doublet. After that, mainly the 5th order aberrations remain to limit the resolution. In this paper, we extend the doublet to quadruplet models also including octupole and dodecapole fields for correcting these higher order aberrations, without introducing any new unwanted ones. We prove the validity of our models by analytical calculations. Also by computer simulations, we show that for beam energy of 5keV and initial angle 10mrad at the corrector object plane, beam size of less than 0.5nm is achieved at the corrector image plane. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Simulation of 3D-treatment plans in head and neck tumors aided by matching of digitally reconstructed radiographs (DRR) and on-line distortion corrected simulator images

    International Nuclear Information System (INIS)

    Lohr, Frank; Schramm, Oliver; Schraube, Peter; Sroka-Perez, Gabriele; Seeber, Steffen; Schlepple, Gerd; Schlegel, Wolfgang; Wannenmacher, Michael

    1997-01-01

    Background and purpose: Simulation of 3D-treatment plans for head and neck malignancy is difficult due to complex anatomy. Therefore, CT-simulation and stereotactic techniques are becoming more common in the treatment preparation, overcoming the need for simulation. However, if simulation is still performed, it is an important step in the treatment preparation/execution chain, since simulation errors, if not detected immediately, can compromise the success of treatment. A recently developed PC-based system for on-line image matching and comparison of digitally reconstructed radiographs (DRR) and distortion corrected simulator monitor images that enables instant correction of field placement errors during the simulation process was evaluated. The range of field placement errors with noncomputer aided simulation is reported. Materials and methods: For 14 patients either a primary 3D-treatment plan or a 3D-boost plan after initial treatment with opposing laterals for head and neck malignancy with a coplanar or non-coplanar two- or three-field technique was simulated. After determining the robustness of the matching process and the accuracy of field placement error detection with phantom measurements, DRRs were generated from the treatment planning CT-dataset of each patient and were interactively matched with on-line simulator images that had undergone correction for geometrical distortion, using a landmark algorithm. Translational field placement errors in all three planes as well as in-plane rotational errors were studied and were corrected immediately. Results: The interactive matching process is very robust with a tolerance of <2 mm when suitable anatomical landmarks are chosen. The accuracy for detection of translational errors in phantom measurements was <1 mm and for in-plane rotational errors the accuracy had a maximum of only 1.5 deg.. For patient simulation, the mean absolute distance of the planned versus simulated isocenter was 6.4 ± 3.9 mm. The in

  11. Accuracy Improvement of Multi-Axis Systems Based on Laser Correction of Volumetric Geometric Errors

    Science.gov (United States)

    Teleshevsky, V. I.; Sokolov, V. A.; Pimushkin, Ya I.

    2018-04-01

    The article describes a volumetric geometric errors correction method for CNC- controlled multi-axis systems (machine-tools, CMMs etc.). The Kalman’s concept of “Control and Observation” is used. A versatile multi-function laser interferometer is used as Observer in order to measure machine’s error functions. A systematic error map of machine’s workspace is produced based on error functions measurements. The error map results into error correction strategy. The article proposes a new method of error correction strategy forming. The method is based on error distribution within machine’s workspace and a CNC-program postprocessor. The postprocessor provides minimal error values within maximal workspace zone. The results are confirmed by error correction of precision CNC machine-tools.

  12. Affine-Invariant Geometric Constraints-Based High Accuracy Simultaneous Localization and Mapping

    Directory of Open Access Journals (Sweden)

    Gangchen Hua

    2017-01-01

    Full Text Available In this study we describe a new appearance-based loop-closure detection method for online incremental simultaneous localization and mapping (SLAM using affine-invariant-based geometric constraints. Unlike other pure bag-of-words-based approaches, our proposed method uses geometric constraints as a supplement to improve accuracy. By establishing an affine-invariant hypothesis, the proposed method excludes incorrect visual words and calculates the dispersion of correctly matched visual words to improve the accuracy of the likelihood calculation. In addition, camera’s intrinsic parameters and distortion coefficients are adequate for this method. 3D measuring is not necessary. We use the mechanism of Long-Term Memory and Working Memory (WM to manage the memory. Only a limited size of the WM is used for loop-closure detection; therefore the proposed method is suitable for large-scale real-time SLAM. We tested our method using the CityCenter and Lip6Indoor datasets. Our proposed method results can effectively correct the typical false-positive localization of previous methods, thus gaining better recall ratios and better precision.

  13. Spatial distortion in MRI with application to stereotactic neurosurgery

    International Nuclear Information System (INIS)

    Morgan, P.S.

    1999-05-01

    The aim of this work was to implement a thorough method for quantifying the errors introduced to frame-based neurosurgical stereotactic procedures by the use of MRI. Chang and Fitzpatrick's reversed gradient distortion correction method was used, in combination with a phantom, to measure these errors. Spatial distortion in MR images of between 1 mm and 2 mm was measured. Further analysis showed that this typically introduced an additional error in the coordinate of the actual treatment point of 0.7 mm. The implications of this are discussed. The main source of distortion in the MR images used for stereotaxis was found to be the head ring. A comparison between imaging sequences and MR scanners revealed that the spatial distortion depends mainly on the bandwidth per pixel of the sequence rather than other differences in the imaging sequences. By comparison with a phase map distortion correction technique, the imaging parameters required to allow successful distortion correction with the reversed gradient method were identified. The most important was the use of full Fourier spin echo acquisitions. The reversed gradient correction method was applied to two contemporary EPI techniques. Considerable improvement was seen in the production of ADC maps after the images had been corrected for distortion. The method also was shown to be valid in application to BOLD fMRl data. (author)

  14. Attenuation correction for renal scintigraphy with 99mTc - DMSA: comparison between Raynaud and the geometric mean methods

    International Nuclear Information System (INIS)

    Argenta, J.; Brambilla, C.R.; Marques da Silva, A.M.

    2009-01-01

    The evaluation of the index of renal function (IF) requires soft-tissue attenuation correction. This paper investigates the impact over the IF, when attenuation correction is applied using the Raynaud method and the geometric mean method in renal planar scintigraphy, using posterior and anterior views. The study was conducted with Monte Carlo simulated images of five GSF family voxel phantoms with different relative uptakes in each kidney from normal (50% -50%) to pathological (10% -90%). The results showed that Raynaud method corrects more efficiently the cases where the renal depth is close to the value of the standard phantom. The geometric mean method showed similar results to the Raynaud method for Baby, Child and Golem. For Helga and Donna models, the errors were above 20%, increasing with relative uptake. Further studies should be conducted to assess the influences of the standard phantom in the correcting attenuation methods. (author)

  15. Attenuation correction for renal scintigraphy with 99mTc-DMSA: analysis between Raynaud and the geometric mean methods

    International Nuclear Information System (INIS)

    Argenta, Jackson; Brambilla, Claudia R.; Silva, Ana Maria M. da

    2010-01-01

    The evaluation of the index of renal function (IF) requires soft-tissue attenuation correction. This paper investigates the impact over the IF, when attenuation correction is applied using the Raynaud method and the Geometric Mean method in renal planar scintigraphy, using posterior and anterior views. The study was conducted with Monte Carlo simulated images of five GSF family voxel phantoms with different relative uptakes in each kidney from normal (50% -50%) to pathological (10% -90%). The results showed that Raynaud method corrects more efficiently the cases where the renal depth is close to the value of the standard phantom. The geometric mean method showed similar results to the Raynaud method for Baby, Child and Golem. For Helga and Donna models, the errors were above 20%, increasing with relative uptake. Further studies should be conducted to assess the influences of the standard phantom in the correcting attenuation methods. (author)

  16. Correction of distortions in distressed mothers' ratings of their preschool children's psychopathology.

    Science.gov (United States)

    Müller, Jörg M; Furniss, Tilman

    2013-11-30

    The often-reported low informant agreement about child psychopathology between multiple informants has lead to various suggestions about how to address discrepant ratings. Among the factors that may lower agreement that have been discussed is informant credibility, reliability, or psychopathology, which is of interest in this paper. We tested three different models, namely, the accuracy, the distortion, and an integrated so-called combined model, that conceptualize parental ratings to assess child psychopathology. The data comprise ratings of child psychopathology from multiple informants (mother, therapist and kindergarten teacher) and ratings of maternal psychopathology. The children were patients in a preschool psychiatry unit (N=247). The results from structural equation modeling show that maternal ratings of child psychopathology were biased by maternal psychopathology (distortion model). Based on this statistical background, we suggest a method to adjust biased maternal ratings. We illustrate the maternal bias by comparing the ratings of mother to expert ratings (combined kindergarten teacher and therapist ratings) and show that the correction equation increases the agreement between maternal and expert ratings. We conclude that this approach may help to reduce misclassification of preschool children as 'clinical' on the basis of biased maternal ratings. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  17. Deep subcritical levels measurements dependents upon kinetic distortion factors

    International Nuclear Information System (INIS)

    Pan Shibiao; Li Xiang; Fu Guo'en; Huang Liyuan; Mu Keliang

    2013-01-01

    The measurement of deep subcritical levels, with the increase of subcriticality, showed that the results impact on the kinetic distortion effect, along with neutron flux strongly deteriorated. Using the diffusion theory, calculations have been carried out to quantify the kinetic distortion correction factors in subcritical systems, and these indicate that epithermal neutron distributions are strongly affected by kinetic distortion. Subcriticality measurements in four different rod-state combination at the zero power device was carried out. The test data analysis shows that, with increasing subcriticality, kinetic distortion effect correction factor gradually increases from 1.052 to 1.065, corresponding reactive correction amount of 0.78β eff ∼ 3.01β eff . Thus, it is necessary to consider the kinetic distortion effect in the deep subcritical reactivity measurements. (authors)

  18. Applying image quality in cell phone cameras: lens distortion

    Science.gov (United States)

    Baxter, Donald; Goma, Sergio R.; Aleksic, Milivoje

    2009-01-01

    This paper describes the framework used in one of the pilot studies run under the I3A CPIQ initiative to quantify overall image quality in cell-phone cameras. The framework is based on a multivariate formalism which tries to predict overall image quality from individual image quality attributes and was validated in a CPIQ pilot program. The pilot study focuses on image quality distortions introduced in the optical path of a cell-phone camera, which may or may not be corrected in the image processing path. The assumption is that the captured image used is JPEG compressed and the cellphone camera is set to 'auto' mode. As the used framework requires that the individual attributes to be relatively perceptually orthogonal, in the pilot study, the attributes used are lens geometric distortion (LGD) and lateral chromatic aberrations (LCA). The goal of this paper is to present the framework of this pilot project starting with the definition of the individual attributes, up to their quantification in JNDs of quality, a requirement of the multivariate formalism, therefore both objective and subjective evaluations were used. A major distinction in the objective part from the 'DSC imaging world' is that the LCA/LGD distortions found in cell-phone cameras, rarely exhibit radial behavior, therefore a radial mapping/modeling cannot be used in this case.

  19. Forward error correction based on algebraic-geometric theory

    CERN Document Server

    A Alzubi, Jafar; M Chen, Thomas

    2014-01-01

    This book covers the design, construction, and implementation of algebraic-geometric codes from Hermitian curves. Matlab simulations of algebraic-geometric codes and Reed-Solomon codes compare their bit error rate using different modulation schemes over additive white Gaussian noise channel model. Simulation results of Algebraic-geometric codes bit error rate performance using quadrature amplitude modulation (16QAM and 64QAM) are presented for the first time and shown to outperform Reed-Solomon codes at various code rates and channel models. The book proposes algebraic-geometric block turbo codes. It also presents simulation results that show an improved bit error rate performance at the cost of high system complexity due to using algebraic-geometric codes and Chase-Pyndiah’s algorithm simultaneously. The book proposes algebraic-geometric irregular block turbo codes (AG-IBTC) to reduce system complexity. Simulation results for AG-IBTCs are presented for the first time.

  20. Geometrical optical illusionists.

    Science.gov (United States)

    Wade, Nicholas J

    2014-01-01

    Geometrical optical illusions were given this title by Oppel in 1855. Variants on such small distortions of visual space were illustrated thereafter, many of which bear the names of those who first described them. Some original forms of the geometrical optical illusions are shown together with 'perceptual portraits' of those who described them. These include: Roget, Chevreul, Fick, Zöllner, Poggendorff, Hering, Kundt, Delboeuf Mach, Helmholtz, Hermann, von Bezold, Müller-Lyer, Lipps, Thiéry, Wundt, Münsterberg, Ebbinghaus, Titchener, Ponzo, Luckiesh, Sander, Ehrenstein, Gregory, Heard, White, Shepard, and. Lingelbach. The illusions are grouped under the headings of orientation, size, the combination of size and orientation, and contrast. Early theories of illusions, before geometrical optical illusions were so named, are mentioned briefly.

  1. Characterization of tissue magnetic susceptibility-induced distortions for MRIgRT

    International Nuclear Information System (INIS)

    Stanescu, T.; Wachowicz, K.; Jaffray, D. A.

    2012-01-01

    Purpose: MR image geometric integrity is one of the building blocks of MRI-guided radiotherapy. In particular, tissue magnetic susceptibility-induced effects are patient-dependent and their behavior is difficult to assess and predict. In this study, the authors investigated in detail the characteristics of susceptibility (χ) distortions in the context of MRIgRT, including the case of two common MR-linac system configurations. Methods: The magnetic field distortions were numerically simulated for several imaging parameters and anatomical sites, i.e., brain, lung, pelvis (with air pockets), and prostate. The simulation process consisted of (a) segmentation of patient CT data into susceptibility relevant anatomical volumes (i.e., soft-tissue, bone and air/lung), (b) conversion of CT data into susceptibility masks by assigning bulk χ values to the structures defined at (a), (c) numerical computations of the local magnetic fields by using a finite difference algorithm, and (d) generation of the geometric distortion maps from the magnetic field distributions. For each patient anatomy, the distortions were quantified at the interfaces of anatomical structures with significantly different χ values. The analysis was performed for two specific orientations of the external main magnetic field (B 0 ) characteristic to the MR-linac systems, specifically along the z-axis for a bore MR scanner and in the (x,y)-plane for a biplanner magnet. The magnetic field local perturbations were reported in ppm. The metrics used to quantify the geometric distortions were the maximum, mean, and range of distortions. The numerical simulation algorithm was validated using phantom data measurements. Results: Susceptibility-induced distortions were determined for both quadratic and patient specific geometries. The numerical simulations showed a good agreement with the experimental data. The measurements were acquired at 1.5 and 3 T and with an encoding gradient varying between 3 and 20 mT/m by

  2. Characterization of tissue magnetic susceptibility-induced distortions for MRIgRT.

    Science.gov (United States)

    Stanescu, T; Wachowicz, K; Jaffray, D A

    2012-12-01

    MR image geometric integrity is one of the building blocks of MRI-guided radiotherapy. In particular, tissue magnetic susceptibility-induced effects are patient-dependent and their behavior is difficult to assess and predict. In this study, the authors investigated in detail the characteristics of susceptibility (χ) distortions in the context of MRIgRT, including the case of two common MR-linac system configurations. The magnetic field distortions were numerically simulated for several imaging parameters and anatomical sites, i.e., brain, lung, pelvis (with air pockets), and prostate. The simulation process consisted of (a) segmentation of patient CT data into susceptibility relevant anatomical volumes (i.e., soft-tissue, bone and air∕lung), (b) conversion of CT data into susceptibility masks by assigning bulk χ values to the structures defined at (a), (c) numerical computations of the local magnetic fields by using a finite difference algorithm, and (d) generation of the geometric distortion maps from the magnetic field distributions. For each patient anatomy, the distortions were quantified at the interfaces of anatomical structures with significantly different χ values. The analysis was performed for two specific orientations of the external main magnetic field (B(0)) characteristic to the MR-linac systems, specifically along the z-axis for a bore MR scanner and in the (x,y)-plane for a biplanner magnet. The magnetic field local perturbations were reported in ppm. The metrics used to quantify the geometric distortions were the maximum, mean, and range of distortions. The numerical simulation algorithm was validated using phantom data measurements. Susceptibility-induced distortions were determined for both quadratic and patient specific geometries. The numerical simulations showed a good agreement with the experimental data. The measurements were acquired at 1.5 and 3 T and with an encoding gradient varying between 3 and 20 mT∕m by using an annular

  3. Size and direction of distortion in geometric-optical illusions: conciliation between the Müller-Lyer and Titchener configurations.

    Science.gov (United States)

    Nemati, Farshad

    2009-01-01

    Over the past few decades, different theories have been advanced to explain geometric-optical illusions based on various perceptual processes such as assimilation and/or contrast. Consistent with the contradictory effects of assimilation and contrast, Pressey's assimilation theory provided an explanation for the Müller-Lyer illusion, but failed to account for the Titchener (Ebbinghaus) illusion. A model that explains both Müller-Lyer and Titchener illusions according to a common underlying process may outline a unified explanation for a variety of geometric-optical illusions. In order to develop such a model, the concept of empty space is introduced as an area of the illusory figure that is not filled by line drawings. It was predicted that the magnitude of illusion would increase with the area of the empty space around the illusory figures. The effect of empty space on the magnitude of perceptual distortion was measured in Müller-Lyer figures, with outward arrowheads of different length. The results indicated an overestimation of the target stimulus in all of the figures. Nevertheless, consistent with the prediction of the present model, the horizontal line in the Müller-Lyer figure with the longest arrowheads appeared shorter than that with the shortest arrowheads, although the size contrast of these figures was the same. According to the analysis proposed in the present study, the area of empty space not only affects the magnitude of illusion but also serves as a contextual cue for the perceptual system to determine the direction of illusion (orientation). The functional relationships between the size contrast and empty space provide a common explanation for the Müller-Lyer, Titchener, and a variety of other geometric-optical illusions.

  4. Geometrical correction of the e-beam proximity effect for raster scan systems

    Science.gov (United States)

    Belic, Nikola; Eisenmann, Hans; Hartmann, Hans; Waas, Thomas

    1999-06-01

    Increasing demands on pattern fidelity and CD accuracy in e- beam lithography require a correction of the e-beam proximity effect. The new needs are mainly coming from OPC at mask level and x-ray lithography. The e-beam proximity limits the achievable resolution and affects neighboring structures causing under- or over-exposion depending on the local pattern densities and process settings. Methods to compensate for this unequilibrated does distribution usually use a dose modulation or multiple passes. In general raster scan systems are not able to apply variable doses in order to compensate for the proximity effect. For system of this kind a geometrical modulation of the original pattern offers a solution for compensation of line edge deviations due to the proximity effect. In this paper a new method for the fast correction of the e-beam proximity effect via geometrical pattern optimization is described. The method consists of two steps. In a first step the pattern dependent dose distribution caused by back scattering is calculated by convolution of the pattern with the long range part of the proximity function. The restriction to the long range part result in a quadratic sped gain in computing time for the transformation. The influence of the short range part coming from forward scattering is not pattern dependent and can therefore be determined separately in a second step. The second calculation yields the dose curve at the border of a written structure. The finite gradient of this curve leads to an edge displacement depending on the amount of underground dosage at the observed position which was previously determined in the pattern dependent step. This unintended edge displacement is corrected by splitting the line into segments and shifting them by multiples of the writers address grid to the opposite direction.

  5. Geometrical Description of fractional quantum Hall quasiparticles

    Science.gov (United States)

    Park, Yeje; Yang, Bo; Haldane, F. D. M.

    2012-02-01

    We examine a description of fractional quantum Hall quasiparticles and quasiholes suggested by a recent geometrical approach (F. D. M. Haldane, Phys. Rev. Lett. 108, 116801 (2011)) to FQH systems, where the local excess electric charge density in the incompressible state is given by a topologically-quantized ``guiding-center spin'' times the Gaussian curvature of a ``guiding-center metric tensor'' that characterizes the local shape of the correlation hole around electrons in the fluid. We use a phenomenological energy function with two ingredients: the shear distortion energy of area-preserving distortions of the fluid, and a local (short-range) approximation to the Coulomb energy of the fluctuation of charge density associated with the Gaussian curvature. Quasiparticles and quasiholes of the 1/3 Laughlin state are modeled as ``punctures'' in the incompressible fluid which then relax by geometric distortion which generates Gaussian curvature, giving rise to the charge-density profile around the topological excitation.

  6. SU-G-JeP2-10: On the Need for a Dynamic Model for Patient-Specific Distortion Corrections for MR-Only Pelvis Treatment Planning

    Energy Technology Data Exchange (ETDEWEB)

    Glide-Hurst, C; Zheng, W [Henry Ford Health System, Detroit, MI (United States); Stehning, C; Weiss, S; Renisch, S [Philips Research Laboratories, Hamburg (Germany)

    2016-06-15

    Purpose: Patient-specific distortions, particularly near tissue/air interfaces, require assessment and possible corrections for MRI-only radiation treatment planning (RTP). However, patients are dynamic due to changes in physiological status and motion during imaging sessions. This work investigated the need for dynamic patient-specific distortion corrections to support pelvis MR-only RTP. Methods: The pelvises of healthy volunteers were imaged at 1.0T, 1.5T, and 3.0T. Patient-specific distortion field maps were generated using a dual-echo gradient-recalled echo (GRE) sequence with B0 field maps obtained from the phase difference between the two echoes acquired at two timepoints: empty and full bladders. To quantify changes arising from respiratory state, end-inhalation and end-expiration data were acquired. Distortion map differences were computed between the empty/full bladder and inhalation/expiration to characterize local changes. The normalized frequency distortion distributions in T2-weighted TSE images were characterized, particularly for simulated prostate planning target volumes (PTVs). Results: Changes in rectal and bowel air location were observed, likely due to changes in bladder filling. Within the PTVs, displacement differences (mean ± stdev, range) were −0.02 ± 0.02 mm (−0.13 to 0.07 mm) for 1.0T, −0.1 ± 0.2 mm (−0.92 to 0.74 mm) for 1.5T, and −0.20 ± 0.03 mm (−0.61 to 0.38 mm) for 3.0T. Local changes of ∼1 mm at the prostate-rectal interface were observed for an extreme case at 1.5T. For end-inhale and end-exhale scans at 3.0T, 99% of the voxels had Δx differences within ±0.25mm, thus the displacement differences due to respiratory state appear negligible in the pelvis. Conclusion: Our work suggests that transient bowel/rectal gas due to bladder filling may yield non-negligible patient-specific distortion differences near the prostate/rectal interface, whereas respiration had minimal effect. A temporal patient model for patient

  7. A geometric model of a V-slit Sun sensor correcting for spacecraft wobble

    Science.gov (United States)

    Mcmartin, W. P.; Gambhir, S. S.

    1994-01-01

    A V-Slit sun sensor is body-mounted on a spin-stabilized spacecraft. During injection from a parking or transfer orbit to some final orbit, the spacecraft may not be dynamically balanced. This may result in wobble about the spacecraft spin axis as the spin axis may not be aligned with the spacecraft's axis of symmetry. While the widely used models in Spacecraft Attitude Determination and Control, edited by Wertz, correct for separation, elevation, and azimuthal mounting biases, spacecraft wobble is not taken into consideration. A geometric approach is used to develop a method for measurement of the sun angle which corrects for the magnitude and phase of spacecraft wobble. The algorithm was implemented using a set of standard mathematical routines for spherical geometry on a unit sphere.

  8. Anisotropic extinction distortion of the galaxy correlation function

    International Nuclear Information System (INIS)

    Fang Wenjuan; Hui Lam; Menard, Brice; May, Morgan; Scranton, Ryan

    2011-01-01

    Similar to the magnification of the galaxies' fluxes by gravitational lensing, the extinction of the fluxes by comic dust, whose existence is recently detected by [B. Menard, R. Scranton, M. Fukugita, and G. Richards, Mon. Not. R. Astron. Soc. 405, 1025 (2010).], also modifies the distribution of a flux-selected galaxy sample. We study the anisotropic distortion by dust extinction to the 3D galaxy correlation function, including magnification bias and redshift distortion at the same time. We find the extinction distortion is most significant along the line of sight and at large separations, similar to that by magnification bias. The correction from dust extinction is negative except at sufficiently large transverse separations, which is almost always opposite to that from magnification bias (we consider a number count slope s>0.4). Hence, the distortions from these two effects tend to reduce each other. At low z (< or approx. 1), the distortion by extinction is stronger than that by magnification bias, but at high z, the reverse holds. We also study how dust extinction affects probes in real space of the baryon acoustic oscillations (BAO) and the linear redshift distortion parameter β. We find its effect on BAO is negligible. However, it introduces a positive scale-dependent correction to β that can be as large as a few percent. At the same time, we also find a negative scale-dependent correction from magnification bias, which is up to percent level at low z, but to ∼40% at high z. These corrections are non-negligible for precision cosmology, and should be considered when testing General Relativity through the scale-dependence of β.

  9. SU-G-IeP1-15: Towards Accurate Cerebral Blood Flow Quantification with Distortion- Corrected Pseudo-Continuous Arterial Spin Labeling

    Energy Technology Data Exchange (ETDEWEB)

    Hoff, M; Rane-Levandovsky, S; Andre, J [University of Washington, Seattle, WA (United States)

    2016-06-15

    Purpose: Traditional arterial spin labeling (ASL) acquisitions with echo planar imaging (EPI) readouts suffer from image distortion due to susceptibility effects, compromising ASL’s ability to accurately quantify cerebral blood flow (CBF) and assess disease-specific patterns associated with CBF abnormalities. Phase labeling for additional coordinate encoding (PLACE) can remove image distortion; our goal is to apply PLACE to improve the quantitative accuracy of ASL CBF in humans. Methods: Four subjects were imaged on a 3T Philips Ingenia scanner using a 16-channel receive coil with a 21/21/10cm (frequency/phase/slice direction) field-of-view. An ASL sequence with a pseudo-continuous ASL (pCASL) labeling scheme was employed to acquire thirty dynamics of single-shot EPI data, with control and label datasets for all dynamics, and PLACE gradients applied on odd dynamics. Parameters included a post-labeling delay = 2s, label duration = 1.8s, flip angle = 90°, TR/TE = 5000/23.5ms, and 2.9/2.9/5.0mm (frequency/phase/slice direction) voxel size. “M0” EPI-reference images and T1-weighted spin-echo images with 0.8/1.0/3.3mm (frequency/phase/slice directions) voxel size were also acquired. Complex conjugate image products of pCASL odd and even dynamics were formed, a linear phase ramp applied, and data expanded and smoothed. Data phase was extracted to map control, label, and M0 magnitude image pixels to their undistorted locations, and images were rebinned to original size. All images were corrected for motion artifacts in FSL 5.0. pCASL images were registered to M0 images, and control and label images were subtracted to compute quantitative CBF maps. Results: pCASL image and CBF map distortions were removed by PLACE in all subjects. Corrected images conformed well to the anatomical T1-weighted reference image, and deviations in corrected CBF maps were evident. Conclusion: Eliminating pCASL distortion with PLACE can improve CBF quantification accuracy using minimal

  10. SU-G-IeP1-15: Towards Accurate Cerebral Blood Flow Quantification with Distortion- Corrected Pseudo-Continuous Arterial Spin Labeling

    International Nuclear Information System (INIS)

    Hoff, M; Rane-Levandovsky, S; Andre, J

    2016-01-01

    Purpose: Traditional arterial spin labeling (ASL) acquisitions with echo planar imaging (EPI) readouts suffer from image distortion due to susceptibility effects, compromising ASL’s ability to accurately quantify cerebral blood flow (CBF) and assess disease-specific patterns associated with CBF abnormalities. Phase labeling for additional coordinate encoding (PLACE) can remove image distortion; our goal is to apply PLACE to improve the quantitative accuracy of ASL CBF in humans. Methods: Four subjects were imaged on a 3T Philips Ingenia scanner using a 16-channel receive coil with a 21/21/10cm (frequency/phase/slice direction) field-of-view. An ASL sequence with a pseudo-continuous ASL (pCASL) labeling scheme was employed to acquire thirty dynamics of single-shot EPI data, with control and label datasets for all dynamics, and PLACE gradients applied on odd dynamics. Parameters included a post-labeling delay = 2s, label duration = 1.8s, flip angle = 90°, TR/TE = 5000/23.5ms, and 2.9/2.9/5.0mm (frequency/phase/slice direction) voxel size. “M0” EPI-reference images and T1-weighted spin-echo images with 0.8/1.0/3.3mm (frequency/phase/slice directions) voxel size were also acquired. Complex conjugate image products of pCASL odd and even dynamics were formed, a linear phase ramp applied, and data expanded and smoothed. Data phase was extracted to map control, label, and M0 magnitude image pixels to their undistorted locations, and images were rebinned to original size. All images were corrected for motion artifacts in FSL 5.0. pCASL images were registered to M0 images, and control and label images were subtracted to compute quantitative CBF maps. Results: pCASL image and CBF map distortions were removed by PLACE in all subjects. Corrected images conformed well to the anatomical T1-weighted reference image, and deviations in corrected CBF maps were evident. Conclusion: Eliminating pCASL distortion with PLACE can improve CBF quantification accuracy using minimal

  11. Study and distortion correction in a selective dissemination of information system

    International Nuclear Information System (INIS)

    Freitas Queiroz, I.O. de.

    1978-03-01

    The Selective Dissemination of Information (S D I) system of the Nuclear Information Center (Brazil) was presented, and some parameters, for the evaluation of performance and distortion were defined. These parameters were quantified for a sample of 35 user's profiles and 25.818 documents. Possible distortion factors were analysed, and some were selected, so that they could be automatically processed. The 35 profiles were up-dated by use of two algorithms developed for this purpose. For the up-dated profiles new values of the parameters were determined and showed that distortion decreased and efficiency improved. Critical points of the system were identified and new studies, on topics investigated superficially, were proposed. (Author) [pt

  12. Correction for tissue attenuation in radionuclide gastric emptying studies: a comparison of a lateral image method and a geometric mean method

    Energy Technology Data Exchange (ETDEWEB)

    Collins, P.J.; Chatterton, B.E. (Royal Adelaide Hospital (Australia)); Horowitz, M.; Shearman, D.J.C. (Adelaide Univ. (Australia). Dept. of Medicine)

    1984-08-01

    Variation in depth of radionuclide within the stomach may result in significant errors in the measurement of gastric emptying if no attempt is made to correct for gamma-ray attenuation by the patient's tissues. A method of attenuation correction, which uses a single posteriorly located scintillation camera and correction factors derived from a lateral image of the stomach, was compared with a two-camera geometric mean method, in phantom studies and in five volunteer subjects. A meal of 100 g of ground beef containing /sup 99/Tcsup(m)-chicken liver, and 150 ml of water was used in the in vivo studies. In all subjects the geometric mean data showed that solid food emptied in two phases: an initial lag period, followed by a linear emptying phase. Using the geometric mean data as a standard, the anterior camera overestimated the 50% emptying time (T/sub 50/) by an average of 15% (range 5-18) and the posterior camera underestimated this parameter by 15% (4-22). The posterior data, corrected for attenuation using the lateral image method, underestimated the T/sub 50/ by 2% (-7 to +7). The difference in the distances of the proximal and distal stomach from the posterior detector was large in all subjects (mean 5.7 cm, range 3.9-7.4).

  13. B0-correction and k-means clustering for accurate and automatic identification of regions with reduced apparent diffusion coefficient (ADC) in adva nced cervical cancer at the time of brachytherapy

    DEFF Research Database (Denmark)

    Haack, Søren; Pedersen, Erik Morre; Vinding, Mads Sloth

    in dose planning of radiotherapy. This study evaluates the use of k-means clustering for automatic user independent delineation of regions of reduced apparent diffusion coefficient (ADC) and the value of B0-correction of DW-MRI for reduction of geometrical distortions during dose planning of brachytherapy...

  14. Direction-dependent waist-shift-difference of Gaussian beam in a multiple-pass zigzag slab amplifier and geometrical optics compensation method.

    Science.gov (United States)

    Li, Zhaoyang; Kurita, Takashi; Miyanaga, Noriaki

    2017-10-20

    Zigzag and non-zigzag beam waist shifts in a multiple-pass zigzag slab amplifier are investigated based on the propagation of a Gaussian beam. Different incident angles in the zigzag and non-zigzag planes would introduce a direction-dependent waist-shift-difference, which distorts the beam quality in both the near- and far-fields. The theoretical model and analytical expressions of this phenomenon are presented, and intensity distributions in the two orthogonal planes are simulated and compared. A geometrical optics compensation method by a beam with 90° rotation is proposed, which not only could correct the direction-dependent waist-shift-difference but also possibly average the traditional thermally induced wavefront-distortion-difference between the horizontal and vertical beam directions.

  15. Correction of distortion of MR pictures for MR-guided robotic sterotactic procedures

    International Nuclear Information System (INIS)

    Jonckheere, E.A.; Kwoh, Y.S.

    1988-01-01

    Ever since magnetic resonance (MR) invaded the medical imaging field, it has played an increasingly important role and is even currently being considered for stereotactic guidance of probes in the brain. While MR pictures indeed convey more clinical information than CT, the geometry of MR pictures is, unfortunately, not as accurate as the geometry of CT pictures. In other words, if a square grid phantom is scanned, then the CT picture will show a square grid, while the MR picture will rather reveal a distorted grid. This distortion is primarily due to small variations in the static magnetic field. This small distortion does not impede radiological diagnosis; however, it is a source of concern if one contemplates utilizing the MR pictures for accurate stereotactic positioning of a probe at a very precise point in the brain. Another area of application where the distortion of the MR picture should be compensated for is the superposition of CT and MR pictures so that both informations could be used for diagnosis or stereotactic purposes. This paper essentially addresses the nonlinear distortion of MR pictures and how it could be compensated for through software manipulation of the MR picture

  16. A holistic calibration method with iterative distortion compensation for stereo deflectometry

    Science.gov (United States)

    Xu, Yongjia; Gao, Feng; Zhang, Zonghua; Jiang, Xiangqian

    2018-07-01

    This paper presents a novel holistic calibration method for stereo deflectometry system to improve the system measurement accuracy. The reconstruction result of stereo deflectometry is integrated with the calculated normal data of the measured surface. The calculation accuracy of the normal data is seriously influenced by the calibration accuracy of the geometrical relationship of the stereo deflectometry system. Conventional calibration approaches introduce form error to the system due to inaccurate imaging model and distortion elimination. The proposed calibration method compensates system distortion based on an iterative algorithm instead of the conventional distortion mathematical model. The initial value of the system parameters are calculated from the fringe patterns displayed on the systemic LCD screen through a reflection of a markless flat mirror. An iterative algorithm is proposed to compensate system distortion and optimize camera imaging parameters and system geometrical relation parameters based on a cost function. Both simulation work and experimental results show the proposed calibration method can significantly improve the calibration and measurement accuracy of a stereo deflectometry. The PV (peak value) of measurement error of a flat mirror can be reduced to 69.7 nm by applying the proposed method from 282 nm obtained with the conventional calibration approach.

  17. Photometric correction for an optical CCD-based system based on the sparsity of an eight-neighborhood gray gradient.

    Science.gov (United States)

    Zhang, Yuzhong; Zhang, Yan

    2016-07-01

    In an optical measurement and analysis system based on a CCD, due to the existence of optical vignetting and natural vignetting, photometric distortion, in which the intensity falls off away from the image center, affects the subsequent processing and measuring precision severely. To deal with this problem, an easy and straightforward method used for photometric distortion correction is presented in this paper. This method introduces a simple polynomial fitting model of the photometric distortion function and employs a particle swarm optimization algorithm to get these model parameters by means of a minimizing eight-neighborhood gray gradient. Compared with conventional calibration methods, this method can obtain the profile information of photometric distortion from only a single common image captured by the optical CCD-based system, with no need for a uniform luminance area source used as a standard reference source and relevant optical and geometric parameters in advance. To illustrate the applicability of this method, numerical simulations and photometric distortions with different lens parameters are evaluated using this method in this paper. Moreover, the application example of temperature field correction for casting billets also demonstrates the effectiveness of this method. The experimental results show that the proposed method is able to achieve the maximum absolute error for vignetting estimation of 0.0765 and the relative error for vignetting estimation from different background images of 3.86%.

  18. Geometrical modified nesbit corporoplasty to correct different types of penile curvature: description of the surgical procedure based on geometrical principles and long-term results.

    Science.gov (United States)

    Vicini, P; Di Nicola, S; Antonini, G; De Berardinis, E; Gentile, V; De Marco, F

    2016-11-01

    We present the use of a modified corporoplasty, based on geometrical principles, to determine the exact site for the incision in the tunica or plaque and the exact amount of albuginea for overlaying to correct with extreme precision the different types of congenital or acquired penile curvature due to Peyronie's disease. To describe our experience with a new surgical procedure for the enhancement of penile curvature avoiding any overcorrection or undercorrection. Between March 2004 and April 2013, a total of 74 patients underwent the geometrical modified corporoplasty. All patients had congenital curvature until 90° or acquired stable penile curvature 'less' than 60°, that made sexual intercourse very difficult or impossible, normal erectile function, absence of hourglass or hinge effect. Preoperative testing included a physical examination, 3 photographs (frontal, dorsal and lateral) of penis during erection, a 10 mcg PGE1-induced erection and Doppler ultrasound, administration of the International Index of Erectile Function (IIEF-15) questionnaire. A follow-up with postoperative evaluation at 12 weeks, 12 and 24 months, included the same preoperative testing. Satisfaction rates were better assessed with the use of validated questionnaire such as the International Erectile Dysfunction Inventory of the Treatment Satisfaction (EDITS). Statistical analysis with Student's t-test was performed using commercially available, personal computer software. A total of 25 patients had congenital penile curvature with a mean deviation of 46.8° (range 40-90), another 49 patients had Peyronie's disease with a mean deviation of 58.4 (range 45-60). No major complications were reported. Postoperative correction of the curvature was achieved in all patients (100%). Neither undercorrection nor overcorrection were recorded. No significant relapse (curvature>15°) occurred in our patients. Shortening of the penis was reported by 74% but did not influence the high overall

  19. SU-F-J-163: In Vivo Quantification of Sequence Parameter Effect On Geometric Distortion Caused by Implanted Titanium Brachytherapy Applicator

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, T; Diak, A; Surucu, M; Yacoub, J; Harkenrider, M; Shea, S [Loyola University Chicago, Maywood, IL (United States)

    2016-06-15

    Purpose: The use of MR to plan and evaluate brachytherapy treatment for cervical cancer is increasing given the availability of MR conditional or safe applicators and MRI’s proven superiority to CT for characterizing soft tissue lesions. The titanium applicators, however, cause geometric distortions or imaging artifacts, which reduce the utility of MRI for dosimetry. We sought to quantify the observed volume of the same applicator on a previously optimized T2 sequence in comparison to the conventional T2 sequence and CT obtained for brachytherapy planning. Methods: Prior work with testing in phantoms showed that increases in readout bandwidth yielded reductions in artifact area and distortion measurements even with voxel increases. Following IRB approval, nine patients with titanium tandem & ovoid applicator (Varian Medical Systems) in place were scanned with a standard periprocedural protocol which included sagittal T2 fast spin echo (FSE) acquisition (res 0.98×0.78×4.0 mm{sup 3}; BW 200Hz). An additional T2-weighted FSE sequence (res 0.98×0.98×3–4 mm{sup 3}; BW500Hz) with increased readout bandwidth, readout voxel size, and echo train length was added to the protocol. Volume measurements of the applicator (from tip to cervical stop) were hand-segmented in Velocity AI 3.1 (Velocity Medical Solutions) for the two T2 FSE sequences and a planning CT obtained shortly after MRI. Differences were analyzed using a paired t-test. Results: Average apparent volumes of the applicator on standard T2 sequence, decreased bandwidth T2 sequence and CT were 5.922±1.283 cm{sup 3}, 4.544±1.524 cm3, and 2.304±0.509 cm{sup 3} respectively. Conclusion: Apparent volumes of a brachytherapy applicator can be compared in vivo. The modified sequence results in decreased apparent size of the cervical applicator. Both MR sequence volumes were larger than the planning CT, which was expected. Future work will focus on the diagnostic quality of the new sequence and quantifying any

  20. Fifth-order canonical geometric aberration analysis of electrostatic round lenses

    CERN Document Server

    Liu Zhi Xiong

    2002-01-01

    In this paper the fifth-order canonical geometric aberration patterns are analyzed and a numerical example is given on the basis of the analytical expressions of fifth-order aberration coefficients derived in the present work. The fifth-order spherical aberration, astigmatism and field curvature, and distortion are similar to the third-order ones and the fifth-order coma is slightly different. Besides, there are two more aberrations which do not exist in the third-order aberration: they are peanut aberration and elliptical coma in accordance with their shapes. In the numerical example, by using a cross-check of the calculated coefficients with those computed through the differential algebraic method, it has been verified that all the expressions are correct and the computational results are reliable with high precision.

  1. TPC track distortions III: fiat lux

    CERN Document Server

    Boyko, I; Dydak, F; Elagin, A; Gostkin, M; Guskov, A; Koreshev, V; Nefedov, Y; Nikolaev, K; Veenhof, R; Wotschack, J; Zhemchugov, A

    2005-01-01

    We present a comprehensive overview and final summary of all four types of static track distortions seen in the HARP TPC, in terms of physical origins, mathematical modelling, and correction algorithms. 'Static'™ distortions are defined as not depending on the event time within the 400 ms long accelerator spill. Calculated static distortions are compared with measurements from cosmic-muon tracks. We characterize track distortions by the r phi residuals of cluster positions with respect to the transverse projection of a helical trajectory constrained by hits in the RPC overlap regions. This method provides a fixed TPC-external reference system (by contrast to the co-moving coordinate system associated with a fit) which solely permits to identify individually, and measure quantitatively, the static TPC track distortions arising from (i) the inhomogeneity of the solenoidal magnetic field, (ii) the inhomogeneity of the electric field from the high-voltage mismatch between the inner and outer TPC field cages, (...

  2. Memory Distortion and Its Avoidance: An Event-Related Potentials Study on False Recognition and Correct Rejection.

    Science.gov (United States)

    Cadavid, Sara; Beato, Maria Soledad

    2016-01-01

    Memory researchers have long been captivated by the nature of memory distortions and have made efforts to identify the neural correlates of true and false memories. However, the underlying mechanisms of avoiding false memories by correctly rejecting related lures remains underexplored. In this study, we employed a variant of the Deese/Roediger-McDermott paradigm to explore neural signatures of committing and avoiding false memories. ERP were obtained for True recognition, False recognition, Correct rejection of new items, and, more importantly, Correct rejection of related lures. With these ERP data, early-frontal, left-parietal, and late right-frontal old/new effects (associated with familiarity, recollection, and monitoring processes, respectively) were analysed. Results indicated that there were similar patterns for True and False recognition in all three old/new effects analysed in our study. Also, False recognition and Correct rejection of related lures activities seemed to share common underlying familiarity-based processes. The ERP similarities between False recognition and Correct rejection of related lures disappeared when recollection processes were examined because only False recognition presented a parietal old/new effect. This finding supported the view that actual false recollections underlie false memories, providing evidence consistent with previous behavioural research and with most ERP and neuroimaging studies. Later, with the onset of monitoring processes, False recognition and Correct rejection of related lures waveforms presented, again, clearly dissociated patterns. Specifically, False recognition and True recognition showed more positive going patterns than Correct rejection of related lures signal and Correct rejection of new items signature. Since False recognition and Correct rejection of related lures triggered familiarity-recognition processes, our results suggest that deciding which items are studied is based more on recollection

  3. Memory Distortion and Its Avoidance: An Event-Related Potentials Study on False Recognition and Correct Rejection.

    Directory of Open Access Journals (Sweden)

    Sara Cadavid

    Full Text Available Memory researchers have long been captivated by the nature of memory distortions and have made efforts to identify the neural correlates of true and false memories. However, the underlying mechanisms of avoiding false memories by correctly rejecting related lures remains underexplored. In this study, we employed a variant of the Deese/Roediger-McDermott paradigm to explore neural signatures of committing and avoiding false memories. ERP were obtained for True recognition, False recognition, Correct rejection of new items, and, more importantly, Correct rejection of related lures. With these ERP data, early-frontal, left-parietal, and late right-frontal old/new effects (associated with familiarity, recollection, and monitoring processes, respectively were analysed. Results indicated that there were similar patterns for True and False recognition in all three old/new effects analysed in our study. Also, False recognition and Correct rejection of related lures activities seemed to share common underlying familiarity-based processes. The ERP similarities between False recognition and Correct rejection of related lures disappeared when recollection processes were examined because only False recognition presented a parietal old/new effect. This finding supported the view that actual false recollections underlie false memories, providing evidence consistent with previous behavioural research and with most ERP and neuroimaging studies. Later, with the onset of monitoring processes, False recognition and Correct rejection of related lures waveforms presented, again, clearly dissociated patterns. Specifically, False recognition and True recognition showed more positive going patterns than Correct rejection of related lures signal and Correct rejection of new items signature. Since False recognition and Correct rejection of related lures triggered familiarity-recognition processes, our results suggest that deciding which items are studied is based more on

  4. A MATCHING METHOD TO REDUCE THE INFLUENCE OF SAR GEOMETRIC DEFORMATION

    Directory of Open Access Journals (Sweden)

    C. Gao

    2018-04-01

    Full Text Available There are large geometrical deformations in SAR image, including foreshortening, layover, shade,which leads to SAR Image matching with low accuracy. Especially in complex terrain area, the control points are difficult to obtain, and the matching is difficult to achieve. Considering the impact of geometric distortions in SAR image pairs, a matching algorithm with a combination of speeded up robust features (SURF and summed of normalize cross correlation (SNCC was proposed, which can avoid the influence of SAR geometric deformation. Firstly, SURF algorithm was utilized to predict the search area. Then the matching point pairs was selected based on summed of normalized cross correlation. Finally, false match points were eliminated by the bidirectional consistency. SURF algorithm can control the range of matching points, and the matching points extracted from the deformation area are eliminated, and the matching points with stable and even distribution are obtained. The experimental results demonstrated that the proposed algorithm had high precision, and can effectively avoid the effect of geometric distortion on SAR image matching. Meet accuracy requirements of the block adjustment with sparse control points.

  5. Tidally distorted exoplanets: Density corrections for short-period hot-Jupiters based solely on observable parameters

    Energy Technology Data Exchange (ETDEWEB)

    Burton, J. R.; Watson, C. A.; Fitzsimmons, A.; Moulds, V. [Astrophysics Research Centre, Queen' s University Belfast, Belfast BT7 1NN (United Kingdom); Pollacco, D.; Wheatley, P. J. [Department of Physics and Astronomy, University of Warwick, Coventry CV4 7AL (United Kingdom); Littlefair, S. P., E-mail: jburton04@qub.ac.uk [Department of Physics and Astronomy, University of Sheffield, Sheffield S3 7RH (United Kingdom)

    2014-07-10

    The close proximity of short-period hot-Jupiters to their parent star means they are subject to extreme tidal forces. This has a profound effect on their structure and, as a result, density measurements that assume that the planet is spherical can be incorrect. We have simulated the tidally distorted surface for 34 known short-period hot-Jupiters, assuming surfaces of constant gravitational equipotential for the planet, and the resulting densities have been calculated based only on observed parameters of the exoplanet systems. Comparing these results to the density values, assuming the planets are spherical, shows that there is an appreciable change in the measured density for planets with very short periods (typically less than two days). For one of the shortest-period systems, WASP-19b, we determine a decrease in bulk density of 12% from the spherical case and, for the majority of systems in this study, this value is in the range of 1%-5%. On the other hand, we also find cases where the distortion is negligible (relative to the measurement errors on the planetary parameters) even in the cases of some very short period systems, depending on the mass ratio and planetary radius. For high-density gas planets requiring apparently anomalously large core masses, density corrections due to tidal deformation could become important for the shortest-period systems.

  6. Spatial Distortion in MRI-Guided Stereotactic Procedures: Evaluation in 1.5-, 3- and 7-Tesla MRI Scanners.

    Science.gov (United States)

    Neumann, Jan-Oliver; Giese, Henrik; Biller, Armin; Nagel, Armin M; Kiening, Karl

    2015-01-01

    Magnetic resonance imaging (MRI) is replacing computed tomography (CT) as the main imaging modality for stereotactic transformations. MRI is prone to spatial distortion artifacts, which can lead to inaccuracy in stereotactic procedures. Modern MRI systems provide distortion correction algorithms that may ameliorate this problem. This study investigates the different options of distortion correction using standard 1.5-, 3- and 7-tesla MRI scanners. A phantom was mounted on a stereotactic frame. One CT scan and three MRI scans were performed. At all three field strengths, two 3-dimensional sequences, volumetric interpolated breath-hold examination (VIBE) and magnetization-prepared rapid acquisition with gradient echo, were acquired, and automatic distortion correction was performed. Global stereotactic transformation of all 13 datasets was performed and two stereotactic planning workflows (MRI only vs. CT/MR image fusion) were subsequently analysed. Distortion correction on the 1.5- and 3-tesla scanners caused a considerable reduction in positional error. The effect was more pronounced when using the VIBE sequences. By using co-registration (CT/MR image fusion), even a lower positional error could be obtained. In ultra-high-field (7 T) MR imaging, distortion correction introduced even higher errors. However, the accuracy of non-corrected 7-tesla sequences was comparable to CT/MR image fusion 3-tesla imaging. MRI distortion correction algorithms can reduce positional errors by up to 60%. For stereotactic applications of utmost precision, we recommend a co-registration to an additional CT dataset. © 2015 S. Karger AG, Basel.

  7. Non-Markovian effect on the geometric phase of a dissipative qubit

    International Nuclear Information System (INIS)

    Chen Juanjuan; Tong Qingjun; An Junhong; Luo Honggang; Oh, C. H.

    2010-01-01

    We studied the geometric phase of a two-level atom coupled to an environment with Lorentzian spectral density. The non-Markovian effect on the geometric phase is explored analytically and numerically. In the weak coupling limit, the lowest order correction to the geometric phase is derived analytically and the general case is calculated numerically. It was found that the correction to the geometric phase is significantly large if the spectral width is small, and in this case the non-Markovian dynamics has a significant impact on the geometric phase. When the spectral width increases, the correction to the geometric phase becomes negligible, which shows the robustness of the geometric phase to the environmental white noises. The result is significant to the quantum information processing based on the geometric phase.

  8. Image Registration to Compensate for EPI Distortion in Patients with Brain Tumors: An Evaluation of Tract-Specific Effects.

    Science.gov (United States)

    Albi, Angela; Meola, Antonio; Zhang, Fan; Kahali, Pegah; Rigolo, Laura; Tax, Chantal M W; Ciris, Pelin Aksit; Essayed, Walid I; Unadkat, Prashin; Norton, Isaiah; Rathi, Yogesh; Olubiyi, Olutayo; Golby, Alexandra J; O'Donnell, Lauren J

    2018-03-01

    Diffusion magnetic resonance imaging (dMRI) provides preoperative maps of neurosurgical patients' white matter tracts, but these maps suffer from echo-planar imaging (EPI) distortions caused by magnetic field inhomogeneities. In clinical neurosurgical planning, these distortions are generally not corrected and thus contribute to the uncertainty of fiber tracking. Multiple image processing pipelines have been proposed for image-registration-based EPI distortion correction in healthy subjects. In this article, we perform the first comparison of such pipelines in neurosurgical patient data. Five pipelines were tested in a retrospective clinical dMRI dataset of 9 patients with brain tumors. Pipelines differed in the choice of fixed and moving images and the similarity metric for image registration. Distortions were measured in two important tracts for neurosurgery, the arcuate fasciculus and corticospinal tracts. Significant differences in distortion estimates were found across processing pipelines. The most successful pipeline used dMRI baseline and T2-weighted images as inputs for distortion correction. This pipeline gave the most consistent distortion estimates across image resolutions and brain hemispheres. Quantitative results of mean tract distortions on the order of 1-2 mm are in line with other recent studies, supporting the potential need for distortion correction in neurosurgical planning. Novel results include significantly higher distortion estimates in the tumor hemisphere and greater effect of image resolution choice on results in the tumor hemisphere. Overall, this study demonstrates possible pitfalls and indicates that care should be taken when implementing EPI distortion correction in clinical settings. Copyright © 2018 by the American Society of Neuroimaging.

  9. FPGA Based Compensation Method for Correcting Distortion in Voltage Inverters

    National Research Council Canada - National Science Library

    Williamson, Kenya D

    2007-01-01

    ...) voltage source inverters. Blanking time distortion is caused by the delay inserted to prevent the short circuit that would occur if the two transistors in the same inverter leg are both on at the same time...

  10. Emittance and beam size distortion due to linear coupling

    International Nuclear Information System (INIS)

    Parzen, G.

    1993-01-01

    At injection, the presence of linear coupling may result in an increased beam emittance and in increased beam dimensions. Results for the emittance in the presence of linear coupling will be found. These results for the emittance distortion show that the harmonics of the skew quadrupole field close to ν x + ν y are the important harmonics. Results will be found for the important driving terms for the emittance distortion. It will be shown that if these driving terms are corrected, then the total emittance is unchanged, var-epsilon x + var-epsilon y = var-epsilon 1 + var-epsilon 2 . Also, the increase in the beam dimensions will be limited to a factor which is less than 1.414. If the correction is good enough, see below for details, one can achieve var-epsilon 1 = var-epsilon x , var-epsilon 2 = var-epsilon where var-epsilon 1 , var-epsilon 2 are the emittances in the presence of coupling, and the beam dimensions are unchanged. Global correction of the emittance and beam size distortion appears possible

  11. Research on geometric rectification of the Large FOV Linear Array Whiskbroom Image

    Science.gov (United States)

    Liu, Dia; Liu, Hui-tong; Dong, Hao; Liu, Xiao-bo

    2015-08-01

    To solve the geometric distortion problem of large FOV linear array whiskbroom image, a model of multi center central projection collinearity equation was founded considering its whiskbroom and linear CCD imaging feature, and the principle of distortion was analyzed. Based on the rectification method with POS, we introduced the angular position sensor data of the servo system, and restored the geometric imaging process exactly. An indirect rectification scheme aiming at linear array imaging with best scanline searching method was adopted, matrixes for calculating the exterior orientation elements was redesigned. We improved two iterative algorithms for this device, and did comparison and analysis. The rectification for the images of airborne imaging experiment showed ideal effect.

  12. Studies of radial distortions of the ATLAS Inner Detector

    CERN Document Server

    The ATLAS collaboration

    2018-01-01

    The measurement of the absolute momentum scale of charged particles provided by the ATLAS inner detector is affected by biases related to geometrical deformations which are not well constrained by the track-based alignment procedure. The focus of this note is on momentum biases related to radial distortions of the inner detector. The $J/\\psi$, $\\Upsilon$, and $Z$-boson resonances decaying into pairs of muons are used to study and quantify such radial distortions in the barrel region of the inner detector. The analysis is performed on data collected in 2016 during Run 2 of the Large Hadron Collider, and corresponding to 33 fb$^{-1}$ of integrated luminosity.

  13. Models of brachial to finger pulse wave distortion and pressure decrement

    NARCIS (Netherlands)

    Gizdulich, P.; Prentza, A.; Wesseling, K.H.

    1997-01-01

    Objective: To model the pulse wave distortion and pressure decrement occurring between brachial and finger arteries. Distortion reversion and decrement correction were also our aims. Methods: Brachial artery pressure was recorded intra-arterially and finger pressure was recorded non-invasively by

  14. Accuracy evaluation of optical distortion calibration by digital image correlation

    Science.gov (United States)

    Gao, Zeren; Zhang, Qingchuan; Su, Yong; Wu, Shangquan

    2017-11-01

    Due to its convenience of operation, the camera calibration algorithm, which is based on the plane template, is widely used in image measurement, computer vision and other fields. How to select a suitable distortion model is always a problem to be solved. Therefore, there is an urgent need for an experimental evaluation of the accuracy of camera distortion calibrations. This paper presents an experimental method for evaluating camera distortion calibration accuracy, which is easy to implement, has high precision, and is suitable for a variety of commonly used lens. First, we use the digital image correlation method to calculate the in-plane rigid body displacement field of an image displayed on a liquid crystal display before and after translation, as captured with a camera. Next, we use a calibration board to calibrate the camera to obtain calibration parameters which are used to correct calculation points of the image before and after deformation. The displacement field before and after correction is compared to analyze the distortion calibration results. Experiments were carried out to evaluate the performance of two commonly used industrial camera lenses for four commonly used distortion models.

  15. Corrections of residual fluorescence distortions for a glancing-emergence-angle x-ray-absorption technique

    International Nuclear Information System (INIS)

    Brewe, D.L.; Pease, D.M.; Budnick, J.I.

    1994-01-01

    Distortions appear in x-ray-absorption spectra obtained by monitoring the fluorescence from thick samples with concentrated absorbing species. The glancing-emergence-angle technique for obtaining spectra from this type of sample eliminates distortions from the measured spectra by monitoring the fluorescence leaving the sample at a small angle relative to the sample surface. This technique is limited by the small signal available from the inherently limited detector solid angle. In addition, no precise estimate of the required restriction on maximum emergent angle θ max has been available. We have calculated residual extended x-ray-absorption fine structure distortions as a function of θ max , and performed experimental tests of the calculations. These calculations provide a means to estimate the required detector geometry for negligible distortions, or alternatively, allow the use of a larger θ max , increasing the available signal, with the remaining residual distortions removed by application of the calculations. The calculations are also applicable to other detector geometries, and account for detectors subtending a large solid angle by an integration over the subtended angle. This represents an improvement over previous calculations. The application to more general detector configurations is also discussed

  16. Correction of distortions in optical coherence tomography imaging of the eye

    Energy Technology Data Exchange (ETDEWEB)

    Podoleanu, Adrian [Applied Optics Group, University of Kent, Canterbury (United Kingdom); Charalambous, Ismini [Applied Optics Group, University of Kent, Canterbury (United Kingdom); Plesea, Lucian [Applied Optics Group, University of Kent, Canterbury (United Kingdom); Dogariu, Aristide [School of Optics, CREOL, University of Central Florida, Orlando, FL (United States); Rosen, Richard [Advanced Retinal Imaging Center, New York Eye and Ear Infirmary, NY (United States)

    2004-04-07

    Optical coherence tomography (OCT) images are affected by artefacts. These artefacts are the result of different factors such as refraction, curvature of the intermediate layers up to the depth of interest and the scanning procedure. The effect of such errors is different, depending on the way the image is acquired, either en-face or longitudinal OCT. We quantify the distortions by evaluating a lateral and an axial error. These measure the lateral and axial deviations of each image point from the object point inside the tissue. We show that the axial distortion can be larger than the achievable depth resolution in modern OCT systems. We have investigated these errors in imaging different tissue: cornea and retina in vivo and an intraocular lens in vitro.

  17. Lifting the geometric frustration through a monoclinic distortion in “114” YBaFe4O7.0: Magnetism and transport

    International Nuclear Information System (INIS)

    Duffort, V.; Sarkar, T.; Caignaert, V.; Pralong, V.; Raveau, B.; Avdeev, M.; Cervellino, A.; Waerenborgh, J.C.; Tsipis, E.V.

    2013-01-01

    The possibility to lift the geometric frustration in the “114” stoichiomeric tetragonal oxide YBaFe 4 O 7.0 by decreasing the temperature has been investigated using neutron and synchrotron powder diffraction techniques. Besides the structural transition from tetragonal to monoclinic symmetry that appears at T S =180 K, a magnetic transition is observed below T N =95 K. The latter corresponds to a lifting of the 3D geometric frustration toward an antiferromagnetic long range ordering, never observed to date in a cubic based “114’” oxide. The magnetic structure, characterized by the propagation vector k 1 =(0,0,½), shows that one iron Fe2 exhibits a larger magnetic moment than the three others, suggesting a possible charge ordering according to the formula YBaFe 3+ Fe 3 2+ O 7.0 . The magnetic M(T) and χ′(T) curves, in agreement with neutron data, confirm the structural and magnetic transitions and evidence the coexistence of residual magnetic frustration. Moreover, the transport measurements show a resistive transition from a thermally activated conduction mechanism to a variable range hopping mechanism at T S =180 K, with a significant increase of the dependence of the resistivity vs. temperature. Mössbauer spectroscopy clearly evidences a change in the electronic configuration of the iron framework at the structural transition as well as coexistence of several oxidation states. The role of barium underbonding in these transitions is discussed. - Graphical abstract: Atomic displacements at the tetragonal-monoclinic transition in YBaFe 4 O 7 . Display Omitted - Highlights: • The structural and magnetic phase transitions of YBaFe 4 O 7 were studied below room temperature. • The tetragonal to monoclinic transition, characterized by NPD and SXRD, was studied using mode crystallography approach. • Monoclinic distortion allows the lifting of the geometrical frustration on the iron sublattice, leading to AF order at T=95 K

  18. Simultaneous correction of attenuation and geometric response in emission tomography applied to nuclear waste drums

    International Nuclear Information System (INIS)

    Thierry, Raphael

    1999-01-01

    Multi-photonic emission tomography is a non destructive technique applied to the control of radioactive waste drums. The emitted gamma rays are detected on the range [50 keV, 2 MeV] by a hyper pure germanium, of high resolution in energy, which enables to set up a detailed list of radionuclides contained within the drum. From different points of measurement located in a transaxial plane of the drum, the activity distribution is computed by a reconstruction algorithm. An algebraic modelling of the physical process has been developed in order to correct the different degrading phenomenon, in particular the attenuation and the detector geometric response. Attenuation through the materials constituting the barrel is the preponderant phenomena. Its ignorance prevents from accurate activity quantification. Its correction has been realised from an attenuation map obtained by a transmission tomograph. The detector geometric response, introducing a blurring within the detection, is compensated by an analytic model. An adequate modelling of those phenomenon is primordial: it highly contributes on a large scale the image quality and the quantification. The image reconstruction, requiring the resolution of sparse linear system, is realised by iterative algorithms. Due to the 'ill-posed' nature of tomographic reconstruction, it is necessary to use regularisation: by introducing an a priori information on the solution, the stabilisation of the methods is carried out. We chose to minimise the Maximum A Posteriori criterion. Its resolution is considered with a half-quadratic regularisation: it permits the preservation of natural discontinuities, and avoids global-over smoothing of the image. It is evaluated on real phantoms and waste drums. Efficient sampling of the data is considered. (author) [fr

  19. Evidence of two-channel distortion effects in positronium formation reactions

    International Nuclear Information System (INIS)

    Macri, P A; Miraglia, J E; Hanssen, J; Fojon, O A; Rivarola, R D

    2004-01-01

    The formation of ground-state positronium in collisions of positrons on hydrogen-like atoms is considered. In previous theoretical works, two-centre distorted wavefunctions were employed to approximate either the initial or the final channel. Here we report results obtained by means of the eikonal final state continuum distorted wave approximation for which asymptotically correct distorted wavefunctions are used for both the initial and final states of the scattering system. Comparison of the present theoretical total cross sections with experimental data reveals that distortion effects become important in both channels as the impact energy decreases. This work also shows that distorted-wave theories may be extended from their usual domain of high impact energies to lower ones. (letter to the editor)

  20. Evidence of two-channel distortion effects in positronium formation reactions

    Energy Technology Data Exchange (ETDEWEB)

    Macri, P A [Instituto de AstronomIa y FIsica del Espacio, Consejo Nacional de Investigaciones CientIficas y Tecnicas-Universidad de Buenos Aires, Casilla de Correo 67, Suc. 28, 1428 Buenos Aires (Argentina); Miraglia, J E [Instituto de AstronomIa y FIsica del Espacio, Consejo Nacional de Investigaciones CientIficas y Tecnicas-Universidad de Buenos Aires, Casilla de Correo 67, Suc. 28, 1428 Buenos Aires (Argentina); Hanssen, J [Laboratoire de Physique Moleculaire et des Collisions, Institute de Physique Rue Arago, Tecnopole 2000, Metz (France); Fojon, O A [Instituto de FIsica de Rosario, Consejo Nacional de Investigaciones CientIficas y Tecnicas-Universidad Nacional de Rosario, Av. Pellegrini 250, 2000 Rosario (Argentina); Rivarola, R D [Instituto de FIsica de Rosario, Consejo Nacional de Investigaciones CientIficas y Tecnicas-Universidad Nacional de Rosario, Av. Pellegrini 250, 2000 Rosario (Argentina)

    2004-03-28

    The formation of ground-state positronium in collisions of positrons on hydrogen-like atoms is considered. In previous theoretical works, two-centre distorted wavefunctions were employed to approximate either the initial or the final channel. Here we report results obtained by means of the eikonal final state continuum distorted wave approximation for which asymptotically correct distorted wavefunctions are used for both the initial and final states of the scattering system. Comparison of the present theoretical total cross sections with experimental data reveals that distortion effects become important in both channels as the impact energy decreases. This work also shows that distorted-wave theories may be extended from their usual domain of high impact energies to lower ones. (letter to the editor)

  1. Johann Joseph on Geometrical-Optical Illusions: A Translation and Commentary.

    Science.gov (United States)

    Wade, Nicholas J; Todorović, Dejan; Phillips, David; Lingelbach, Bernd

    2017-01-01

    The term geometrical-optical illusions was coined by Johann Joseph Oppel (1815-1894) in 1855 in order to distinguish spatial distortions of size and orientation from the broader illusions of the senses. We present a translation of Oppel's article and a commentary on the material described in it. Oppel did much more than give a name to a class of visual spatial distortions. He examined a variety of figures and phenomena that were precursors of later, named illusions, and attempted to quantify and interpret them.

  2. Practical estimate of gradient nonlinearity for implementation of apparent diffusion coefficient bias correction.

    Science.gov (United States)

    Malkyarenko, Dariya I; Chenevert, Thomas L

    2014-12-01

    To describe an efficient procedure to empirically characterize gradient nonlinearity and correct for the corresponding apparent diffusion coefficient (ADC) bias on a clinical magnetic resonance imaging (MRI) scanner. Spatial nonlinearity scalars for individual gradient coils along superior and right directions were estimated via diffusion measurements of an isotropicic e-water phantom. Digital nonlinearity model from an independent scanner, described in the literature, was rescaled by system-specific scalars to approximate 3D bias correction maps. Correction efficacy was assessed by comparison to unbiased ADC values measured at isocenter. Empirically estimated nonlinearity scalars were confirmed by geometric distortion measurements of a regular grid phantom. The applied nonlinearity correction for arbitrarily oriented diffusion gradients reduced ADC bias from 20% down to 2% at clinically relevant offsets both for isotropic and anisotropic media. Identical performance was achieved using either corrected diffusion-weighted imaging (DWI) intensities or corrected b-values for each direction in brain and ice-water. Direction-average trace image correction was adequate only for isotropic medium. Empiric scalar adjustment of an independent gradient nonlinearity model adequately described DWI bias for a clinical scanner. Observed efficiency of implemented ADC bias correction quantitatively agreed with previous theoretical predictions and numerical simulations. The described procedure provides an independent benchmark for nonlinearity bias correction of clinical MRI scanners.

  3. Investigation of image distortion due to MCP electronic readout misalignment and correction via customized GUI application

    Science.gov (United States)

    Vitucci, G.; Minniti, T.; Tremsin, A. S.; Kockelmann, W.; Gorini, G.

    2018-04-01

    The MCP-based neutron counting detector is a novel device that allows high spatial resolution and time-resolved neutron radiography and tomography with epithermal, thermal and cold neutrons. Time resolution is possible by the high readout speeds of ~ 1200 frames/sec, allowing high resolution event counting with relatively high rates without spatial resolution degradation due to event overlaps. The electronic readout is based on a Timepix sensor, a CMOS pixel readout chip developed at CERN. Currently, a geometry of a quad Timepix detector is used with an active format of 28 × 28 mm2 limited by the size of the Timepix quad (2 × 2 chips) readout. Measurements of a set of high-precision micrometers test samples have been performed at the Imaging and Materials Science & Engineering (IMAT) beamline operating at the ISIS spallation neutron source (U.K.). The aim of these experiments was the full characterization of the chip misalignment and of the gaps between each pad in the quad Timepix sensor. Such misalignment causes distortions of the recorded shape of the sample analyzed. We present in this work a post-processing image procedure that considers and corrects these effects. Results of the correction will be discussed and the efficacy of this method evaluated.

  4. Safe and sensible preprocessing and baseline correction of pupil-size data.

    Science.gov (United States)

    Mathôt, Sebastiaan; Fabius, Jasper; Van Heusden, Elle; Van der Stigchel, Stefan

    2018-02-01

    Measurement of pupil size (pupillometry) has recently gained renewed interest from psychologists, but there is little agreement on how pupil-size data is best analyzed. Here we focus on one aspect of pupillometric analyses: baseline correction, i.e., analyzing changes in pupil size relative to a baseline period. Baseline correction is useful in experiments that investigate the effect of some experimental manipulation on pupil size. In such experiments, baseline correction improves statistical power by taking into account random fluctuations in pupil size over time. However, we show that baseline correction can also distort data if unrealistically small pupil sizes are recorded during the baseline period, which can easily occur due to eye blinks, data loss, or other distortions. Divisive baseline correction (corrected pupil size = pupil size/baseline) is affected more strongly by such distortions than subtractive baseline correction (corrected pupil size = pupil size - baseline). We discuss the role of baseline correction as a part of preprocessing of pupillometric data, and make five recommendations: (1) before baseline correction, perform data preprocessing to mark missing and invalid data, but assume that some distortions will remain in the data; (2) use subtractive baseline correction; (3) visually compare your corrected and uncorrected data; (4) be wary of pupil-size effects that emerge faster than the latency of the pupillary response allows (within ±220 ms after the manipulation that induces the effect); and (5) remove trials on which baseline pupil size is unrealistically small (indicative of blinks and other distortions).

  5. Partial fourier and parallel MR image reconstruction with integrated gradient nonlinearity correction.

    Science.gov (United States)

    Tao, Shengzhen; Trzasko, Joshua D; Shu, Yunhong; Weavers, Paul T; Huston, John; Gray, Erin M; Bernstein, Matt A

    2016-06-01

    To describe how integrated gradient nonlinearity (GNL) correction can be used within noniterative partial Fourier (homodyne) and parallel (SENSE and GRAPPA) MR image reconstruction strategies, and demonstrate that performing GNL correction during, rather than after, these routines mitigates the image blurring and resolution loss caused by postreconstruction image domain based GNL correction. Starting from partial Fourier and parallel magnetic resonance imaging signal models that explicitly account for GNL, noniterative image reconstruction strategies for each accelerated acquisition technique are derived under the same core mathematical assumptions as their standard counterparts. A series of phantom and in vivo experiments on retrospectively undersampled data were performed to investigate the spatial resolution benefit of integrated GNL correction over conventional postreconstruction correction. Phantom and in vivo results demonstrate that the integrated GNL correction reduces the image blurring introduced by the conventional GNL correction, while still correcting GNL-induced coarse-scale geometrical distortion. Images generated from undersampled data using the proposed integrated GNL strategies offer superior depiction of fine image detail, for example, phantom resolution inserts and anatomical tissue boundaries. Noniterative partial Fourier and parallel imaging reconstruction methods with integrated GNL correction reduce the resolution loss that occurs during conventional postreconstruction GNL correction while preserving the computational efficiency of standard reconstruction techniques. Magn Reson Med 75:2534-2544, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  6. Distortion

    OpenAIRE

    Schultz, Isabella Odorico; Zmylon, Nanna Nielsen; Britze, Juliane

    2014-01-01

    This paper investigates the audience’s perception of the music festival Distortion. By conducting a field-study focusing on the subject’s perception of Distortion, their perception of the Distortion-attendants, and their perception on the promotion of Distortion, the paper will relate the audience perception to the promotion of the event. Using the group’s own research on the promotion of Distortion, the paper points out both the consistencies and the inconsistencies between the promotion and...

  7. Estimation and Correction of Geometric Distortions in Side-Scan Sonar Images

    Science.gov (United States)

    1990-03-01

    Dissertation Funding was provided by the Conselho Nacional de Desinvolvemento Cientifico e Tecnologico (CNPq), an agency of the Government of the Federative...sponsorship of the Conselho Nacional de Desenvolvi- mento Cientifico e Tecnoldgico (CNPq), an agency of the Government of the Federative Republic of Brazil, and...Desenvolvimento Cientifico e Tecnol6gico (CNPq). The facilities used at MIT were maintained in part by grants from the National Science Foundation and the

  8. Reduction of false positives in the detection of architectural distortion in mammograms by using a geometrically constrained phase portrait model

    International Nuclear Information System (INIS)

    Ayres, Fabio J.; Rangayyan, Rangaraj M.

    2007-01-01

    Objective One of the commonly missed signs of breast cancer is architectural distortion. We have developed techniques for the detection of architectural distortion in mammograms, based on the analysis of oriented texture through the application of Gabor filters and a linear phase portrait model. In this paper, we propose constraining the shape of the general phase portrait model as a means to reduce the false-positive rate in the detection of architectural distortion. Material and methods The methods were tested with one set of 19 cases of architectural distortion and 41 normal mammograms, and with another set of 37 cases of architectural distortion. Results Sensitivity rates of 84% with 4.5 false positives per image and 81% with 10 false positives per image were obtained for the two sets of images. Conclusion The adoption of a constrained phase portrait model with a symmetric matrix and the incorporation of its condition number in the analysis resulted in a reduction in the false-positive rate in the detection of architectural distortion. The proposed techniques, dedicated for the detection and localization of architectural distortion, should lead to efficient detection of early signs of breast cancer. (orig.)

  9. Assessment and characterization of the total geometric uncertainty in Gamma Knife radiosurgery using polymer gels

    International Nuclear Information System (INIS)

    Moutsatsos, A.; Karaiskos, P.; Pantelis, E.; Georgiou, E.; Petrokokkinos, L.; Sakelliou, L.; Torrens, M.; Seimenis, I.

    2013-01-01

    Purpose: This work proposes and implements an experimental methodology, based on polymer gels, for assessing the total geometric uncertainty and characterizing its contributors in Gamma Knife (GK) radiosurgery. Methods: A treatment plan consisting of 26, 4-mm GK single shot dose distributions, covering an extended region of the Leksell stereotactic space, was prepared and delivered to a polymer gel filled polymethyl methacrylate (PMMA) head phantom (16 cm diameter) used to accurately reproduce every link in the GK treatment chain. The center of each shot served as a “control point” in the assessment of the GK total geometric uncertainty, which depends on (a) the spatial dose delivery uncertainty of the PERFEXION GK unit used in this work, (b) the spatial distortions inherent in MR images commonly used for target delineation, and (c) the geometric uncertainty contributor associated with the image registration procedure performed by the Leksell GammaPlan (LGP) treatment planning system (TPS), in the case that registration is directly based on the apparent fiducial locations depicted in each MR image by the N-shaped rods on the Leksell localization box. The irradiated phantom was MR imaged at 1.5 T employing a T2-weighted pulse sequence. Four image series were acquired by alternating the frequency encoding axis and reversing the read gradient polarity, thus allowing the characterization of the MR-related spatial distortions. Results: MR spatial distortions stemming from main field (B 0 ) inhomogeneity as well as from susceptibility and chemical shift phenomena (also known as sequence dependent distortions) were found to be of the order of 0.5 mm, while those owing to gradient nonlinearities (also known as sequence independent distortions) were found to increase with distance from the MR scanner isocenter extending up to 0.47 mm at an Euclidean distance of 69.6 mm. Regarding the LGP image registration procedure, the corresponding average contribution to the total

  10. Assessment and characterization of the total geometric uncertainty in Gamma Knife radiosurgery using polymer gels.

    Science.gov (United States)

    Moutsatsos, A; Karaiskos, P; Petrokokkinos, L; Sakelliou, L; Pantelis, E; Georgiou, E; Torrens, M; Seimenis, I

    2013-03-01

    This work proposes and implements an experimental methodology, based on polymer gels, for assessing the total geometric uncertainty and characterizing its contributors in Gamma Knife (GK) radiosurgery. A treatment plan consisting of 26, 4-mm GK single shot dose distributions, covering an extended region of the Leksell stereotactic space, was prepared and delivered to a polymer gel filled polymethyl methacrylate (PMMA) head phantom (16 cm diameter) used to accurately reproduce every link in the GK treatment chain. The center of each shot served as a "control point" in the assessment of the GK total geometric uncertainty, which depends on (a) the spatial dose delivery uncertainty of the PERFEXION GK unit used in this work, (b) the spatial distortions inherent in MR images commonly used for target delineation, and (c) the geometric uncertainty contributor associated with the image registration procedure performed by the Leksell GammaPlan (LGP) treatment planning system (TPS), in the case that registration is directly based on the apparent fiducial locations depicted in each MR image by the N-shaped rods on the Leksell localization box. The irradiated phantom was MR imaged at 1.5 T employing a T2-weighted pulse sequence. Four image series were acquired by alternating the frequency encoding axis and reversing the read gradient polarity, thus allowing the characterization of the MR-related spatial distortions. MR spatial distortions stemming from main field (B0) inhomogeneity as well as from susceptibility and chemical shift phenomena (also known as sequence dependent distortions) were found to be of the order of 0.5 mm, while those owing to gradient nonlinearities (also known as sequence independent distortions) were found to increase with distance from the MR scanner isocenter extending up to 0.47 mm at an Euclidean distance of 69.6 mm. Regarding the LGP image registration procedure, the corresponding average contribution to the total geometric uncertainty ranged from

  11. MATLAB based beam orbit correction system of HLS storage ring

    International Nuclear Information System (INIS)

    Ding Shichuan; Liu Gongfa; Xuan Ke; Li Weimin; Wang Lin; Wang Jigang; Li Chuan; Bao Xun; Guo Weiqun

    2006-01-01

    The distortion of closed orbit usually causes much side effect which is harmful to synchrotron radiation source such as HLS, so it is necessary to correct the distortion of closed orbit. In this paper, the correction principle, development procedure and test of MATLAB based on beam orbit correction system of HLS storage ring are described. The correction system is consisted of the beam orbit measure system, corrector magnet system and the control system, and the beam orbit correction code based on MATLAB is working on the operation interface. The data of the beam orbit are analyzed and calculated firstly, and then the orbit is corrected by changing corrector strength via control system. The test shows that the distortion of closed orbit is from max 4.468 mm before correction to max 0.299 mm after correction as well as SDEV is from 2.986 mm to 0.087 mm. So the correction system reaches the design goal. (authors)

  12. Geometrical influences on multi-pass laser forming

    International Nuclear Information System (INIS)

    Edwardson, S P; Abed, E; Bartkowiak, K; Dearden, G; Watkins, K G

    2006-01-01

    Laser forming (LF) offers the industrial promise of controlled shaping of metallic and non-metallic components for prototyping, the correction of design shape or distortion and precision adjustment applications. The potential process advantages include precise incremental adjustment, flexibility of application and no mechanical 'spring-back' effect. To date there has been a considerable amount of work carried out on two-dimensional LF, using multi-pass straight line scan strategies to produce a reasonably controlled bend angle in a number of materials, including aerospace alloys. A key area, however, where there is a limited understanding, is the variation in bend angle per pass during multi-pass LF along a single irradiation track; in particular, the decrease in bend angle per pass after many irradiations for a given set of process parameters. Understanding this is essential if the process is to be fully controlled in a manufacturing environment. The research presented in this paper highlights the current theories as to why this occurs and proposes a further reason based on the geometrical effects of the component deformation, which in turn influences the process parameters per pass. This theory is confirmed through empirical analysis of the 2D LF process

  13. Effects of Visual Feedback Distortion on Gait Adaptation: Comparison of Implicit Visual Distortion Versus Conscious Modulation on Retention of Motor Learning.

    Science.gov (United States)

    Kim, Seung-Jae; Ogilvie, Mitchell; Shimabukuro, Nathan; Stewart, Trevor; Shin, Joon-Ho

    2015-09-01

    Visual feedback can be used during gait rehabilitation to improve the efficacy of training. We presented a paradigm called visual feedback distortion; the visual representation of step length was manipulated during treadmill walking. Our prior work demonstrated that an implicit distortion of visual feedback of step length entails an unintentional adaptive process in the subjects' spatial gait pattern. Here, we investigated whether the implicit visual feedback distortion, versus conscious correction, promotes efficient locomotor adaptation that relates to greater retention of a task. Thirteen healthy subjects were studied under two conditions: (1) we implicitly distorted the visual representation of their gait symmetry over 14 min, and (2) with help of visual feedback, subjects were told to walk on the treadmill with the intent of attaining the gait asymmetry observed during the first implicit trial. After adaptation, the visual feedback was removed while subjects continued walking normally. Over this 6-min period, retention of preserved asymmetric pattern was assessed. We found that there was a greater retention rate during the implicit distortion trial than that of the visually guided conscious modulation trial. This study highlights the important role of implicit learning in the context of gait rehabilitation by demonstrating that training with implicit visual feedback distortion may produce longer lasting effects. This suggests that using visual feedback distortion could improve the effectiveness of treadmill rehabilitation processes by influencing the retention of motor skills.

  14. A simple and efficient dispersion correction to the Hartree-Fock theory (2): Incorporation of a geometrical correction for the basis set superposition error.

    Science.gov (United States)

    Yoshida, Tatsusada; Hayashi, Takahisa; Mashima, Akira; Chuman, Hiroshi

    2015-10-01

    One of the most challenging problems in computer-aided drug discovery is the accurate prediction of the binding energy between a ligand and a protein. For accurate estimation of net binding energy ΔEbind in the framework of the Hartree-Fock (HF) theory, it is necessary to estimate two additional energy terms; the dispersion interaction energy (Edisp) and the basis set superposition error (BSSE). We previously reported a simple and efficient dispersion correction, Edisp, to the Hartree-Fock theory (HF-Dtq). In the present study, an approximation procedure for estimating BSSE proposed by Kruse and Grimme, a geometrical counterpoise correction (gCP), was incorporated into HF-Dtq (HF-Dtq-gCP). The relative weights of the Edisp (Dtq) and BSSE (gCP) terms were determined to reproduce ΔEbind calculated with CCSD(T)/CBS or /aug-cc-pVTZ (HF-Dtq-gCP (scaled)). The performance of HF-Dtq-gCP (scaled) was compared with that of B3LYP-D3(BJ)-bCP (dispersion corrected B3LYP with the Boys and Bernadi counterpoise correction (bCP)), by taking ΔEbind (CCSD(T)-bCP) of small non-covalent complexes as 'a golden standard'. As a critical test, HF-Dtq-gCP (scaled)/6-31G(d) and B3LYP-D3(BJ)-bCP/6-31G(d) were applied to the complex model for HIV-1 protease and its potent inhibitor, KNI-10033. The present results demonstrate that HF-Dtq-gCP (scaled) is a useful and powerful remedy for accurately and promptly predicting ΔEbind between a ligand and a protein, albeit it is a simple correction procedure. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Distortion of depth perception in virtual environments using stereoscopic displays: quantitative assessment and corrective measures

    Science.gov (United States)

    Kleiber, Michael; Winkelholz, Carsten

    2008-02-01

    The aim of the presented research was to quantify the distortion of depth perception when using stereoscopic displays. The visualization parameters of the used virtual reality system such as perspective, haploscopic separation and width of stereoscopic separation were varied. The experiment was designed to measure distortion in depth perception according to allocentric frames of reference. The results of the experiments indicate that some of the parameters have an antithetic effect which allows to compensate the distortion of depth perception for a range of depths. In contrast to earlier research which reported underestimation of depth perception we found that depth was overestimated when using true projection parameters according to the position of the eyes of the user and display geometry.

  16. A variational image-based approach to the correction of susceptibility artifacts in the alignment of diffusion weighted and structural MRI.

    Science.gov (United States)

    Tao, Ran; Fletcher, P Thomas; Gerber, Samuel; Whitaker, Ross T

    2009-01-01

    This paper presents a method for correcting the geometric and greyscale distortions in diffusion-weighted MRI that result from inhomogeneities in the static magnetic field. These inhomogeneities may due to imperfections in the magnet or to spatial variations in the magnetic susceptibility of the object being imaged--so called susceptibility artifacts. Echo-planar imaging (EPI), used in virtually all diffusion weighted acquisition protocols, assumes a homogeneous static field, which generally does not hold for head MRI. The resulting distortions are significant, sometimes more than ten millimeters. These artifacts impede accurate alignment of diffusion images with structural MRI, and are generally considered an obstacle to the joint analysis of connectivity and structure in head MRI. In principle, susceptibility artifacts can be corrected by acquiring (and applying) a field map. However, as shown in the literature and demonstrated in this paper, field map corrections of susceptibility artifacts are not entirely accurate and reliable, and thus field maps do not produce reliable alignment of EPIs with corresponding structural images. This paper presents a new, image-based method for correcting susceptibility artifacts. The method relies on a variational formulation of the match between an EPI baseline image and a corresponding T2-weighted structural image but also specifically accounts for the physics of susceptibility artifacts. We derive a set of partial differential equations associated with the optimization, describe the numerical methods for solving these equations, and present results that demonstrate the effectiveness of the proposed method compared with field-map correction.

  17. Effects of galvanic distortions on magnetotelluric data: Interpretation ...

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    But in the case of field data the problem is ... The distorted data set is corrected using the MT response for DRS model and further ... ments, the apparent resistivity and phase at differ- ... from the telluric field, which is of galvanic or inductive ...

  18. Hologram production and representation for corrected image

    Science.gov (United States)

    Jiao, Gui Chao; Zhang, Rui; Su, Xue Mei

    2015-12-01

    In this paper, a CCD sensor device is used to record the distorted homemade grid images which are taken by a wide angle camera. The distorted images are corrected by using methods of position calibration and correction of gray with vc++ 6.0 and opencv software. Holography graphes for the corrected pictures are produced. The clearly reproduced images are obtained where Fresnel algorithm is used in graph processing by reducing the object and reference light from Fresnel diffraction to delete zero-order part of the reproduced images. The investigation is useful in optical information processing and image encryption transmission.

  19. Chromatic aberration correction: an enhancement to the calibration of low-cost digital dermoscopes.

    Science.gov (United States)

    Wighton, Paul; Lee, Tim K; Lui, Harvey; McLean, David; Atkins, M Stella

    2011-08-01

    We present a method for calibrating low-cost digital dermoscopes that corrects for color and inconsistent lighting and also corrects for chromatic aberration. Chromatic aberration is a form of radial distortion that often occurs in inexpensive digital dermoscopes and creates red and blue halo-like effects on edges. Being radial in nature, distortions due to chromatic aberration are not constant across the image, but rather vary in both magnitude and direction. As a result, distortions are not only visually distracting but could also mislead automated characterization techniques. Two low-cost dermoscopes, based on different consumer-grade cameras, were tested. Color is corrected by imaging a reference and applying singular value decomposition to determine the transformation required to ensure accurate color reproduction. Lighting is corrected by imaging a uniform surface and creating lighting correction maps. Chromatic aberration is corrected using a second-order radial distortion model. Our results for color and lighting calibration are consistent with previously published results, while distortions due to chromatic aberration can be reduced by 42-47% in the two systems considered. The disadvantages of inexpensive dermoscopy can be quickly substantially mitigated with a suitable calibration procedure. © 2011 John Wiley & Sons A/S.

  20. The research on multi-projection correction based on color coding grid array

    Science.gov (United States)

    Yang, Fan; Han, Cheng; Bai, Baoxing; Zhang, Chao; Zhao, Yunxiu

    2017-10-01

    There are many disadvantages such as lower timeliness, greater manual intervention in multi-channel projection system, in order to solve the above problems, this paper proposes a multi-projector correction technology based on color coding grid array. Firstly, a color structured light stripe is generated by using the De Bruijn sequences, then meshing the feature information of the color structured light stripe image. We put the meshing colored grid intersection as the center of the circle, and build a white solid circle as the feature sample set of projected images. It makes the constructed feature sample set not only has the perceptual localization, but also has good noise immunity. Secondly, we establish the subpixel geometric mapping relationship between the projection screen and the individual projectors by using the structure of light encoding and decoding based on the color array, and the geometrical mapping relation is used to solve the homography matrix of each projector. Lastly the brightness inconsistency of the multi-channel projection overlap area is seriously interfered, it leads to the corrected image doesn't fit well with the observer's visual needs, and we obtain the projection display image of visual consistency by using the luminance fusion correction algorithm. The experimental results show that this method not only effectively solved the problem of distortion of multi-projection screen and the issue of luminance interference in overlapping region, but also improved the calibration efficient of multi-channel projective system and reduced the maintenance cost of intelligent multi-projection system.

  1. Image distortion due to refraction by planar surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Arizaga, R; Cap, N; Rabal, H; Trivi, M [Centro de Investigaciones Opticas (CONICET La Plata-CIC) and OPTIMO Dto de Ciencias Basicas, Fac. de Ingenieria UNLP, PO Box 3, 1897 Gonnet, La Plata (Argentina)

    2010-01-15

    The term 'apparent depth' is commonly treated in textbooks as an issue easily understandable from the point of view of paraxial optical geometrical optics. Nevertheless, everyday life tells us that most of the time the observation of objects immersed in water is made under a great range of visual angles where the paraxial approximation is not valid. Here we developed a non-paraxial treatment to calculate the position and shape of the image of objects immersed in liquids of different refractive indices. The approach was focused on the parametric positions of the images of a single point at different viewing angles. Then we calculated how the image of an extended object is distorted. By using the Matlab software, it is possible to visualize the images for different geometrical conditions. We also include the analysis for refractive index with negative values as is the case of metamaterials.

  2. Image distortion due to refraction by planar surfaces

    International Nuclear Information System (INIS)

    Arizaga, R; Cap, N; Rabal, H; Trivi, M

    2010-01-01

    The term 'apparent depth' is commonly treated in textbooks as an issue easily understandable from the point of view of paraxial optical geometrical optics. Nevertheless, everyday life tells us that most of the time the observation of objects immersed in water is made under a great range of visual angles where the paraxial approximation is not valid. Here we developed a non-paraxial treatment to calculate the position and shape of the image of objects immersed in liquids of different refractive indices. The approach was focused on the parametric positions of the images of a single point at different viewing angles. Then we calculated how the image of an extended object is distorted. By using the Matlab software, it is possible to visualize the images for different geometrical conditions. We also include the analysis for refractive index with negative values as is the case of metamaterials.

  3. Geometric Hypergraph Learning for Visual Tracking

    OpenAIRE

    Du, Dawei; Qi, Honggang; Wen, Longyin; Tian, Qi; Huang, Qingming; Lyu, Siwei

    2016-01-01

    Graph based representation is widely used in visual tracking field by finding correct correspondences between target parts in consecutive frames. However, most graph based trackers consider pairwise geometric relations between local parts. They do not make full use of the target's intrinsic structure, thereby making the representation easily disturbed by errors in pairwise affinities when large deformation and occlusion occur. In this paper, we propose a geometric hypergraph learning based tr...

  4. Vacuum energy density near static distorted black holes

    International Nuclear Information System (INIS)

    Frolov, V.P.; Sanchez, N.

    1986-01-01

    We investigate the contribution of massless fields of spins 0, 1/2, and 1 to the vacuum polarization near the event horizon of static Ricci-flat space-times. We do not assume any particular spatial symmetry. Within the Page-Brown ''ansatz'' we calculate 2 >/sup ren/ and /sup ren/ near static distorted black holes, for both the Hartle-Hawking (Vertical Bar>/sub H/) and Boulware (Vertical Bar>/sub B/) vacua. Using Israel's description of static space-times, we express these quantities in an invariant geometric way. We obtain that 2 >/sub H//sup ren/ and /sub H//sup ren/ near the horizon depend only on the two-dimensional geometry of the horizon surface. We find 2 >/sub H//sup ren/ = (1/48π 2 )K 0 , 0 0 >/sub H//sup ren/ = (7α+12β )K 0 2 -α/sup( 2 )ΔK 0 . $K sub 0: is the Gaussian curvature of the horizon, and α and β are numerical coefficients depending on the spin of a field. The term in /sup( 2 )ΔK 0 is characteristic of the distortion of the black hole. When the event horizon is not distorted, K 0 is a constant and this term disappears

  5. Correcting Spatial Variance of RCM for GEO SAR Imaging Based on Time-Frequency Scaling

    Science.gov (United States)

    Yu, Ze; Lin, Peng; Xiao, Peng; Kang, Lihong; Li, Chunsheng

    2016-01-01

    Compared with low-Earth orbit synthetic aperture radar (SAR), a geosynchronous (GEO) SAR can have a shorter revisit period and vaster coverage. However, relative motion between this SAR and targets is more complicated, which makes range cell migration (RCM) spatially variant along both range and azimuth. As a result, efficient and precise imaging becomes difficult. This paper analyzes and models spatial variance for GEO SAR in the time and frequency domains. A novel algorithm for GEO SAR imaging with a resolution of 2 m in both the ground cross-range and range directions is proposed, which is composed of five steps. The first is to eliminate linear azimuth variance through the first azimuth time scaling. The second is to achieve RCM correction and range compression. The third is to correct residual azimuth variance by the second azimuth time-frequency scaling. The fourth and final steps are to accomplish azimuth focusing and correct geometric distortion. The most important innovation of this algorithm is implementation of the time-frequency scaling to correct high-order azimuth variance. As demonstrated by simulation results, this algorithm can accomplish GEO SAR imaging with good and uniform imaging quality over the entire swath. PMID:27428974

  6. Models of brachial to finger pulse wave distortion and pressure decrement.

    Science.gov (United States)

    Gizdulich, P; Prentza, A; Wesseling, K H

    1997-03-01

    To model the pulse wave distortion and pressure decrement occurring between brachial and finger arteries. Distortion reversion and decrement correction were also our aims. Brachial artery pressure was recorded intra-arterially and finger pressure was recorded non-invasively by the Finapres technique in 53 adult human subjects. Mean pressure was subtracted from each pressure waveform and Fourier analysis applied to the pulsations. A distortion model was estimated for each subject and averaged over the group. The average inverse model was applied to the full finger pressure waveform. The pressure decrement was modelled by multiple regression on finger systolic and diastolic levels. Waveform distortion could be described by a general, frequency dependent model having a resonance at 7.3 Hz. The general inverse model has an anti-resonance at this frequency. It converts finger to brachial pulsations thereby reducing average waveform distortion from 9.7 (s.d. 3.2) mmHg per sample for the finger pulse to 3.7 (1.7) mmHg for the converted pulse. Systolic and diastolic level differences between finger and brachial arterial pressures changed from -4 (15) and -8 (11) to +8 (14) and +8 (12) mmHg, respectively, after inverse modelling, with pulse pressures correct on average. The pressure decrement model reduced both the mean and the standard deviation of systolic and diastolic level differences to 0 (13) and 0 (8) mmHg. Diastolic differences were thus reduced most. Brachial to finger pulse wave distortion due to wave reflection in arteries is almost identical in all subjects and can be modelled by a single resonance. The pressure decrement due to flow in arteries is greatest for high pulse pressures superimposed on low means.

  7. High resolution T{sub 2}{sup *}-weighted magnetic resonance imaging at 3 Tesla using PROPELLER-EPI

    Energy Technology Data Exchange (ETDEWEB)

    Kraemer, Martin; Reichenbach, Juergen R. [Jena University Hospital (Germany). Medical Physics Group

    2014-09-01

    We report the application of PROPELLER-EPI for high resolution T{sub 2}{sup *}-weighted imaging with sub-millimeter in-plane resolution on a clinical 3 Tesla scanner. Periodically rotated blades of a long-axis PROPELLER-EPI sequence were acquired with fast gradient echo readout and acquisition matrix of 320 x 50 per blade. Images were reconstructed by using 2D-gridding, phase and geometric distortion correction and compensation of resonance frequency drifts that occurred during extended measurements. To characterize these resonance frequency offsets, short FID calibration measurements were added to the PROPELLER-EPI sequence. Functional PROPELLER-EPI was performed with volunteers using a simple block design of right handed finger tapping. Results indicate that PROPELLER-EPI can be employed for fast, high resolution T{sub 2}{sup *}-weighted imaging provided geometric distortions and possible resonance frequency drifts are properly corrected. Even small resonance frequency drifts below 10 Hz as well as non-corrected geometric distortions degraded image quality substantially. In the initial fMRI experiment image quality and signal-to-noise ratio was sufficient for obtaining high resolution functional activation maps. (orig.)

  8. Analysis of reforming process of large distorted ring in final enlarging forging

    International Nuclear Information System (INIS)

    Miyazawa, Takeshi; Murai, Etsuo

    2002-01-01

    In the construction of reactors or pressure vessels for oil chemical plants and nuclear power stations, mono block open-die forging rings are often utilized. Generally, a large forged ring is manufactured by means of enlarging forging with reductions of the wall thickness. During the enlarging process the circular ring is often distorted and becomes an ellipse in shape. However the shape control of the ring is a complicated work. This phenomenon makes the matter still worse in forging of larger rings. In order to make precision forging of large rings, we have developed the forging method using a v-shape anvil. The v-shape anvil is geometrically adjusted to fit the distorted ring in the final circle and reform automatically the shape of the ring during enlarging forging. This paper has analyzed the reforming process of distorted ring by computer program based on F.E.M. and examined the effect on the precision of ring forging. (author)

  9. Pentacam Scheimpflug quantitative imaging of the crystalline lens and intraocular lens.

    Science.gov (United States)

    Rosales, Patricia; Marcos, Susana

    2009-05-01

    To implement geometrical and optical distortion correction methods for anterior segment Scheimpflug images obtained with a commercially available system (Pentacam, Oculus Optikgeräte GmbH). Ray tracing algorithms were implemented to obtain corrected ocular surface geometry from the original images captured by the Pentacam's CCD camera. As details of the optical layout were not fully provided by the manufacturer, an iterative procedure (based on imaging of calibrated spheres) was developed to estimate the camera lens specifications. The correction procedure was tested on Scheimpflug images of a physical water cell model eye (with polymethylmethacrylate cornea and a commercial IOL of known dimensions) and of a normal human eye previously measured with a corrected optical and geometrical distortion Scheimpflug camera (Topcon SL-45 [Topcon Medical Systems Inc] from the Vrije University, Amsterdam, Holland). Uncorrected Scheimpflug images show flatter surfaces and thinner lenses than in reality. The application of geometrical and optical distortion correction algorithms improves the accuracy of the estimated anterior lens radii of curvature by 30% to 40% and of the estimated posterior lens by 50% to 100%. The average error in the retrieved radii was 0.37 and 0.46 mm for the anterior and posterior lens radii of curvature, respectively, and 0.048 mm for lens thickness. The Pentacam Scheimpflug system can be used to obtain quantitative information on the geometry of the crystalline lens, provided that geometrical and optical distortion correction algorithms are applied, within the accuracy of state-of-the art phakometry and biometry. The techniques could improve with exact knowledge of the technical specifications of the instrument, improved edge detection algorithms, consideration of aspheric and non-rotationally symmetrical surfaces, and introduction of a crystalline gradient index.

  10. Do Lumped-Parameter Models Provide the Correct Geometrical Damping?

    DEFF Research Database (Denmark)

    Andersen, Lars

    response during excitation and the geometrical damping related to free vibrations of a hexagonal footing. The optimal order of a lumped-parameter model is determined for each degree of freedom, i.e. horizontal and vertical translation as well as torsion and rocking. In particular, the necessity of coupling...... between horizontal sliding and rocking is discussed....

  11. Vertical dispersion produced by random closed orbit distortions and sextupoles

    International Nuclear Information System (INIS)

    Suzuki, Toshio.

    1977-01-01

    Vertical dispersion appears even in a machine designed with plane symmetry because of vertical closed orbit distortions, linear coupling and coupling due to sextupoles. This gives rise to several undesirable effects in an electron-positron storage ring such as PEP. Vertical dispersion at the interaction point will increase beam height and reduce luminosity. Vertical dispersion around the ring will modify vertical emittance and partition numbers for synchrotron radiation damping. It will also induce betatron-synchrotron resonance and affect chromaticity correction. Vertical dispersion due to random closed orbit distortions and sextupoles has been studied by Piwinski, and he has indicated that correction of chromaticity and chromatic change of β-function is important. However, he has assumed one error element and evaluated the dispersion at the position of the element. We generalize his argument to a more realistic case and derive more precise criteria for the correction of vertical dispersion. Horizontal dispersion due to perturbations is also studied. Vertical dispersion due to linear coupling is neglected in this note, since it has been studied by other authors. 7 refs

  12. Cognitive distortions as a component and treatment focus of pathological gambling: a review.

    Science.gov (United States)

    Fortune, Erica E; Goodie, Adam S

    2012-06-01

    The literature on the role of cognitive distortions in the understanding and treatment of pathological gambling (PG) is reviewed, with sections focusing on (a) conceptual underpinnings of cognitive distortions, (b) cognitive distortions related to PG, (c) PG therapies that target cognitive distortions, (d) methodological factors and outcome variations, and (e) conclusions and prescriptive recommendations. The conceptual background for distortions related to PG lies in the program of heuristics and biases (Kahneman & Tversky, 1974) as well as other errors identified in basic psychology. The literature has focused on distortions arising from the representativeness heuristic (gambler's fallacy, overconfidence, and trends in number picking), the availability heuristic (illusory correlation, other individuals' wins, and inherent memory bias), and other sources (the illusion of control and double switching). Some therapies have incorporated cognitive restructuring within broader cognitive-behavioral therapies, with success. Other therapies have focused more narrowly on correcting distorted beliefs, more often with limited success. It is concluded that the literature establishes the role of cognitive distortions in PG and suggests therapies with particularly good promise, but is in need of further enrichment.

  13. Image quality assessment based on multiscale geometric analysis.

    Science.gov (United States)

    Gao, Xinbo; Lu, Wen; Tao, Dacheng; Li, Xuelong

    2009-07-01

    Reduced-reference (RR) image quality assessment (IQA) has been recognized as an effective and efficient way to predict the visual quality of distorted images. The current standard is the wavelet-domain natural image statistics model (WNISM), which applies the Kullback-Leibler divergence between the marginal distributions of wavelet coefficients of the reference and distorted images to measure the image distortion. However, WNISM fails to consider the statistical correlations of wavelet coefficients in different subbands and the visual response characteristics of the mammalian cortical simple cells. In addition, wavelet transforms are optimal greedy approximations to extract singularity structures, so they fail to explicitly extract the image geometric information, e.g., lines and curves. Finally, wavelet coefficients are dense for smooth image edge contours. In this paper, to target the aforementioned problems in IQA, we develop a novel framework for IQA to mimic the human visual system (HVS) by incorporating the merits from multiscale geometric analysis (MGA), contrast sensitivity function (CSF), and the Weber's law of just noticeable difference (JND). In the proposed framework, MGA is utilized to decompose images and then extract features to mimic the multichannel structure of HVS. Additionally, MGA offers a series of transforms including wavelet, curvelet, bandelet, contourlet, wavelet-based contourlet transform (WBCT), and hybrid wavelets and directional filter banks (HWD), and different transforms capture different types of image geometric information. CSF is applied to weight coefficients obtained by MGA to simulate the appearance of images to observers by taking into account many of the nonlinearities inherent in HVS. JND is finally introduced to produce a noticeable variation in sensory experience. Thorough empirical studies are carried out upon the LIVE database against subjective mean opinion score (MOS) and demonstrate that 1) the proposed framework has

  14. Characteristic signatures of quantum criticality driven by geometrical frustration.

    Science.gov (United States)

    Tokiwa, Yoshifumi; Stingl, Christian; Kim, Moo-Sung; Takabatake, Toshiro; Gegenwart, Philipp

    2015-04-01

    Geometrical frustration describes situations where interactions are incompatible with the lattice geometry and stabilizes exotic phases such as spin liquids. Whether geometrical frustration of magnetic interactions in metals can induce unconventional quantum critical points is an active area of research. We focus on the hexagonal heavy fermion metal CeRhSn, where the Kondo ions are located on distorted kagome planes stacked along the c axis. Low-temperature specific heat, thermal expansion, and magnetic Grüneisen parameter measurements prove a zero-field quantum critical point. The linear thermal expansion, which measures the initial uniaxial pressure derivative of the entropy, displays a striking anisotropy. Critical and noncritical behaviors along and perpendicular to the kagome planes, respectively, prove that quantum criticality is driven be geometrical frustration. We also discovered a spin flop-type metamagnetic crossover. This excludes an itinerant scenario and suggests that quantum criticality is related to local moments in a spin liquid-like state.

  15. Geometrical correction for the inter- and intramolecular basis set superposition error in periodic density functional theory calculations.

    Science.gov (United States)

    Brandenburg, Jan Gerit; Alessio, Maristella; Civalleri, Bartolomeo; Peintinger, Michael F; Bredow, Thomas; Grimme, Stefan

    2013-09-26

    We extend the previously developed geometrical correction for the inter- and intramolecular basis set superposition error (gCP) to periodic density functional theory (DFT) calculations. We report gCP results compared to those from the standard Boys-Bernardi counterpoise correction scheme and large basis set calculations. The applicability of the method to molecular crystals as the main target is tested for the benchmark set X23. It consists of 23 noncovalently bound crystals as introduced by Johnson et al. (J. Chem. Phys. 2012, 137, 054103) and refined by Tkatchenko et al. (J. Chem. Phys. 2013, 139, 024705). In order to accurately describe long-range electron correlation effects, we use the standard atom-pairwise dispersion correction scheme DFT-D3. We show that a combination of DFT energies with small atom-centered basis sets, the D3 dispersion correction, and the gCP correction can accurately describe van der Waals and hydrogen-bonded crystals. Mean absolute deviations of the X23 sublimation energies can be reduced by more than 70% and 80% for the standard functionals PBE and B3LYP, respectively, to small residual mean absolute deviations of about 2 kcal/mol (corresponding to 13% of the average sublimation energy). As a further test, we compute the interlayer interaction of graphite for varying distances and obtain a good equilibrium distance and interaction energy of 6.75 Å and -43.0 meV/atom at the PBE-D3-gCP/SVP level. We fit the gCP scheme for a recently developed pob-TZVP solid-state basis set and obtain reasonable results for the X23 benchmark set and the potential energy curve for water adsorption on a nickel (110) surface.

  16. Optimal Missing Pixel Estimation Algorithms for Large Detector Arrays

    National Research Council Canada - National Science Library

    Qi, Hairong

    1999-01-01

    .... The focus is on image correction and image restoration. Besides extending the conventional polynomial approximation method to correct both radiometric and geometric distortions, we demonstrate the successful use of the thin-plate spline (TPS...

  17. Determination of geometric inaccuracies in stereotactic magnetic resonance imaging

    International Nuclear Information System (INIS)

    Novotny, J. Jr.; Novotny, J.; Vymazal, J.

    2001-01-01

    The precision of stereotactic localization and volume determination was examined by using a Leksell's stereotactic frame, Leksell's MRI indicator box and Siemens 1 T MAGNETOM Expert scanner. The distortions in the spatial stereotactic coordinates and errors in volume determination were assessed through measurements employing a special phantom which simulated patient's head with different target volumes. The average geometrical distortion values gave evidence of a satisfactory precision for stereotactic MRI localization (average distortion 0.5 mm). No significant dependence of the magnitude of these distortions on the MRI examination sequence, MRI slice orientation, or spatial position of the measured point in the volume examined was observed. The mean percentage error of the volume determination determined by the technical capabilities of the imaging and treatment planning system was 10% for smaller volumes (below 2000 mm 3 ) and 5% for larger volumes (above 10000 mm 3 ). The subjective errors of volume determination were expressed as the standard deviation of mean volume calculated based on contours recorded by six independent observers (physicians) for each of five selected target volumes (meningioma, metastases, acoustic neurinoma, pituitary adenoma and arteriovenous malformation). The minimum standard deviation for volume recorded by six independent physicians was 5% (for metastases), the maximum value was 40 % (for arteriovenous malformation)

  18. Improved distorted wave theory with the localized virial conditions

    Science.gov (United States)

    Hahn, Y. K.; Zerrad, E.

    2009-12-01

    The distorted wave theory is operationally improved to treat the full collision amplitude, such that the corrections to the distorted wave Born amplitude can be systematically calculated. The localized virial conditions provide the tools necessary to test the quality of successive approximations at each stage and to optimize the solution. The details of the theoretical procedure are explained in concrete terms using a collisional ionization model and variational trial functions. For the first time, adjustable parameters associated with an approximate scattering solution can be fully determined by the theory. A small number of linear parameters are introduced to examine the convergence property and the effectiveness of the new approach.

  19. Analysis and correction of Landsat 4 and 5 Thematic Mapper Sensor Data

    Science.gov (United States)

    Bernstein, R.; Hanson, W. A.

    1985-01-01

    Procedures for the correction and registration and registration of Landsat TM image data are examined. The registration of Landsat-4 TM images of San Francisco to Landsat-5 TM images of the San Francisco using the interactive geometric correction program and the cross-correlation technique is described. The geometric correction program and cross-correlation results are presented. The corrections of the TM data to a map reference and to a cartographic database are discussed; geometric and cartographic analyses are applied to the registration results.

  20. A locally adaptive algorithm for shadow correction in color images

    Science.gov (United States)

    Karnaukhov, Victor; Kober, Vitaly

    2017-09-01

    The paper deals with correction of color images distorted by spatially nonuniform illumination. A serious distortion occurs in real conditions when a part of the scene containing 3D objects close to a directed light source is illuminated much brighter than the rest of the scene. A locally-adaptive algorithm for correction of shadow regions in color images is proposed. The algorithm consists of segmentation of shadow areas with rank-order statistics followed by correction of nonuniform illumination with human visual perception approach. The performance of the proposed algorithm is compared to that of common algorithms for correction of color images containing shadow regions.

  1. Dark-field electron holography for the measurement of geometric phase

    International Nuclear Information System (INIS)

    Hytch, M.J.; Houdellier, F.; Huee, F.; Snoeck, E.

    2011-01-01

    The genesis, theoretical basis and practical application of the new electron holographic dark-field technique for mapping strain in nanostructures are presented. The development places geometric phase within a unified theoretical framework for phase measurements by electron holography. The total phase of the transmitted and diffracted beams is described as a sum of four contributions: crystalline, electrostatic, magnetic and geometric. Each contribution is outlined briefly and leads to the proposal to measure geometric phase by dark-field electron holography (DFEH). The experimental conditions, phase reconstruction and analysis are detailed for off-axis electron holography using examples from the field of semiconductors. A method for correcting for thickness variations will be proposed and demonstrated using the phase from the corresponding bright-field electron hologram. -- Highlights: → Unified description of phase measurements in electron holography. → Detailed description of dark-field electron holography for geometric phase measurements. → Correction procedure for systematic errors due to thickness variations.

  2. Objective and expert-independent validation of retinal image registration algorithms by a projective imaging distortion model.

    Science.gov (United States)

    Lee, Sangyeol; Reinhardt, Joseph M; Cattin, Philippe C; Abràmoff, Michael D

    2010-08-01

    Fundus camera imaging of the retina is widely used to diagnose and manage ophthalmologic disorders including diabetic retinopathy, glaucoma, and age-related macular degeneration. Retinal images typically have a limited field of view, and multiple images can be joined together using an image registration technique to form a montage with a larger field of view. A variety of methods for retinal image registration have been proposed, but evaluating such methods objectively is difficult due to the lack of a reference standard for the true alignment of the individual images that make up the montage. A method of generating simulated retinal images by modeling the geometric distortions due to the eye geometry and the image acquisition process is described in this paper. We also present a validation process that can be used for any retinal image registration method by tracing through the distortion path and assessing the geometric misalignment in the coordinate system of the reference standard. The proposed method can be used to perform an accuracy evaluation over the whole image, so that distortion in the non-overlapping regions of the montage components can be easily assessed. We demonstrate the technique by generating test image sets with a variety of overlap conditions and compare the accuracy of several retinal image registration models. Copyright 2010 Elsevier B.V. All rights reserved.

  3. Sudan-decoding generalized geometric Goppa codes

    DEFF Research Database (Denmark)

    Heydtmann, Agnes Eileen

    2003-01-01

    Generalized geometric Goppa codes are vector spaces of n-tuples with entries from different extension fields of a ground field. They are derived from evaluating functions similar to conventional geometric Goppa codes, but allowing evaluation in places of arbitrary degree. A decoding scheme...... for these codes based on Sudan's improved algorithm is presented and its error-correcting capacity is analyzed. For the implementation of the algorithm it is necessary that the so-called increasing zero bases of certain spaces of functions are available. A method to obtain such bases is developed....

  4. Time-dependent phase error correction using digital waveform synthesis

    Science.gov (United States)

    Doerry, Armin W.; Buskirk, Stephen

    2017-10-10

    The various technologies presented herein relate to correcting a time-dependent phase error generated as part of the formation of a radar waveform. A waveform can be pre-distorted to facilitate correction of an error induced into the waveform by a downstream operation/component in a radar system. For example, amplifier power droop effect can engender a time-dependent phase error in a waveform as part of a radar signal generating operation. The error can be quantified and an according complimentary distortion can be applied to the waveform to facilitate negation of the error during the subsequent processing of the waveform. A time domain correction can be applied by a phase error correction look up table incorporated into a waveform phase generator.

  5. Novel methods in track-based alignment to correct for time-dependent distortions of the ATLAS Inner Detector

    CERN Document Server

    Estrada Pastor, Oscar; The ATLAS collaboration

    2017-01-01

    ATLAS is a multipurpose experiment at the LHC proton-proton collider. Its physics goals require high resolution and unbiased measurement of all charged particle kinematic parameters. These critically depend on the layout and performance of the tracking system and the quality of its alignment. For the LHC Run II, the system has been upgraded with the installation of a new pixel layer, the Insertable B-layer (IBL). The offline track alignment of the ATLAS tracking system has to deal with about 700,000 degrees of freedom (DoF) defining its geometrical parameters, representing a considerable numerical challenge in terms of both CPU time and precision. An outline of the track based alignment approach and its implementation within the ATLAS software is presented. Special attention is paid to describe the techniques allowing to pinpoint and eliminate track parameters biases. During Run-II, ATLAS Inner Detector Alignment framework has been adapted and upgraded to correct very short time scale movements of the sub-det...

  6. Novel methods in track-based alignment to correct for time-dependent distortions of the ATLAS Inner Detector

    CERN Document Server

    Estrada Pastor, Oscar; The ATLAS collaboration

    2017-01-01

    ATLAS is a multipurpose experiment at the LHC proton-proton collider. Its physics goals require high resolution, unbiased measurement of all charged particle kinematic parameters. These critically depend on the layout and performance of the tracking system and the quality of its offline alignment. For the LHC Run II, the system has been upgraded with the installation of a new pixel layer, the Insertable B-layer (IBL). Offline track alignment of the ATLAS tracking system has to deal with about 700,000 degrees of freedom (DoF) defining its geometrical parameters, representing a considerable numerical challenge in terms of both CPU time and precision. An outline of the track based alignment approach and its implementation within the ATLAS software will be presented. Special attention will be paid to describe the techniques allowing to pinpoint and eliminate track parameters biases due to alignment. During Run-II, ATLAS Inner Detector Alignment framework has been adapted and upgraded to correct very short time sc...

  7. An Improved InSAR Image Co-Registration Method for Pairs with Relatively Big Distortions or Large Incoherent Areas

    Directory of Open Access Journals (Sweden)

    Zhenwei Chen

    2016-09-01

    Full Text Available Co-registration is one of the most important steps in interferometric synthetic aperture radar (InSAR data processing. The standard offset-measurement method based on cross-correlating uniformly distributed patches takes no account of specific geometric transformation between images or characteristics of ground scatterers. Hence, it is inefficient and difficult to obtain satisfying co-registration results for image pairs with relatively big distortion or large incoherent areas. Given this, an improved co-registration strategy is proposed in this paper which takes both the geometric features and image content into consideration. Firstly, some geometric transformations including scale, flip, rotation, and shear between images were eliminated based on the geometrical information, and the initial co-registration polynomial was obtained. Then the registration points were automatically detected by integrating the signal-to-clutter-ratio (SCR thresholds and the amplitude information, and a further co-registration process was performed to refine the polynomial. Several comparison experiments were carried out using 2 TerraSAR-X data from the Hong Kong airport and 21 PALSAR data from the Donghai Bridge. Experiment results demonstrate that the proposed method brings accuracy and efficiency improvements for co-registration and processing abilities in the cases of big distortion between images or large incoherent areas in the images. For most co-registrations, the proposed method can enhance the reliability and applicability of co-registration and thus promote the automation to a higher level.

  8. An Improved InSAR Image Co-Registration Method for Pairs with Relatively Big Distortions or Large Incoherent Areas.

    Science.gov (United States)

    Chen, Zhenwei; Zhang, Lei; Zhang, Guo

    2016-09-17

    Co-registration is one of the most important steps in interferometric synthetic aperture radar (InSAR) data processing. The standard offset-measurement method based on cross-correlating uniformly distributed patches takes no account of specific geometric transformation between images or characteristics of ground scatterers. Hence, it is inefficient and difficult to obtain satisfying co-registration results for image pairs with relatively big distortion or large incoherent areas. Given this, an improved co-registration strategy is proposed in this paper which takes both the geometric features and image content into consideration. Firstly, some geometric transformations including scale, flip, rotation, and shear between images were eliminated based on the geometrical information, and the initial co-registration polynomial was obtained. Then the registration points were automatically detected by integrating the signal-to-clutter-ratio (SCR) thresholds and the amplitude information, and a further co-registration process was performed to refine the polynomial. Several comparison experiments were carried out using 2 TerraSAR-X data from the Hong Kong airport and 21 PALSAR data from the Donghai Bridge. Experiment results demonstrate that the proposed method brings accuracy and efficiency improvements for co-registration and processing abilities in the cases of big distortion between images or large incoherent areas in the images. For most co-registrations, the proposed method can enhance the reliability and applicability of co-registration and thus promote the automation to a higher level.

  9. Distortion compensation in interferometric testing of mirrors

    International Nuclear Information System (INIS)

    Robinson, Brian M.; Reardon, Patrick J.

    2009-01-01

    We present a method to compensate for the imaging distortion encountered in interferometric testing of mirrors, which is introduced by interferometer optics as well as from geometric projection errors. Our method involves placing a mask, imprinted with a regular square grid, over the mirror and finding a transformation that relates the grid coordinates to coordinates in the base plane of the parent surface. This method can be used on finished mirrors since no fiducials have to be applied to the surfaces. A critical step in the process requires that the grid coordinates be projected onto the mirror base plane before the regression is performed. We apply the method successfully during a center-of-curvature null test of an F/2 off-axis paraboloid

  10. Grids in topographic maps reduce distortions in the recall of learned object locations.

    Science.gov (United States)

    Edler, Dennis; Bestgen, Anne-Kathrin; Kuchinke, Lars; Dickmann, Frank

    2014-01-01

    To date, it has been shown that cognitive map representations based on cartographic visualisations are systematically distorted. The grid is a traditional element of map graphics that has rarely been considered in research on perception-based spatial distortions. Grids do not only support the map reader in finding coordinates or locations of objects, they also provide a systematic structure for clustering visual map information ("spatial chunks"). The aim of this study was to examine whether different cartographic kinds of grids reduce spatial distortions and improve recall memory for object locations. Recall performance was measured as both the percentage of correctly recalled objects (hit rate) and the mean distance errors of correctly recalled objects (spatial accuracy). Different kinds of grids (continuous lines, dashed lines, crosses) were applied to topographic maps. These maps were also varied in their type of characteristic areas (LANDSCAPE) and different information layer compositions (DENSITY) to examine the effects of map complexity. The study involving 144 participants shows that all experimental cartographic factors (GRID, LANDSCAPE, DENSITY) improve recall performance and spatial accuracy of learned object locations. Overlaying a topographic map with a grid significantly reduces the mean distance errors of correctly recalled map objects. The paper includes a discussion of a square grid's usefulness concerning object location memory, independent of whether the grid is clearly visible (continuous or dashed lines) or only indicated by crosses.

  11. Bending Distortion Analysis of a Steel Shaft Manufacturing Chain from Cold Drawing to Grinding

    Science.gov (United States)

    Dias, Vinicius Waechter; da Silva Rocha, Alexandre; Zottis, Juliana; Dong, Juan; Epp, Jérémy; Zoch, Hans Werner

    2017-04-01

    Shafts are usually manufactured from bars that are cold drawn, cut machined, induction hardened, straightened, and finally ground. The main distortion is characterized by bending that appears after induction hardening and is corrected by straightening and/or grinding. In this work, the consequence of the variation of manufacturing parameters on the distortion was analyzed for a complete manufacturing route for production of induction hardened shafts made of Grade 1045 steel. A DoE plan was implemented varying the drawing angle, cutting method, induction hardening layer depth, and grinding penetration depth. The distortion was determined by calculating curvature vectors from dimensional analysis by 3D coordinate measurements. Optical microscopy, microhardness testing, residual stress analysis, and FEM process simulation were used to evaluate and understand effects of the main carriers of distortion potential. The drawing process was identified as the most significant influence on the final distortion of the shafts.

  12. Impedance Based Analysis of DFIG Stator Current Unbalance and Distortion Suppression Strategies

    DEFF Research Database (Denmark)

    Song, Yipeng; Zhou, Dao; Blaabjerg, Frede

    2016-01-01

    The control strategies of Doubly Fed Induction Generator (DFIG) system output current unbalance and distortion suppression have been well investigated in detail, with the implementation of two kinds of resonant regulators, i.e., conventional Resonance (R) regulator or Vector Proportional Integral...... reshaping though the introduction of R and VPI regulator. It is pointed out that, when implemented in the DFIG system output current unbalance and distortion suppression, the VPI regulator (equivalent to the combination of virtual positive inductor and virtual positive resistor) has two advantages over R...... regulator (equivalent to the combination of virtual positive resistor and virtual negative inductor), i.e., better high order harmonic distortion suppression. The theoretical analysis and MATLAB simulation results have validated the correctness of this conclusion....

  13. Publisher Correction: Geometric constraints during epithelial jamming

    Science.gov (United States)

    Atia, Lior; Bi, Dapeng; Sharma, Yasha; Mitchel, Jennifer A.; Gweon, Bomi; Koehler, Stephan A.; DeCamp, Stephen J.; Lan, Bo; Kim, Jae Hun; Hirsch, Rebecca; Pegoraro, Adrian F.; Lee, Kyu Ha; Starr, Jacqueline R.; Weitz, David A.; Martin, Adam C.; Park, Jin-Ah; Butler, James P.; Fredberg, Jeffrey J.

    2018-06-01

    In the version of this Article originally published, the Supplementary Movies were linked to the wrong descriptions. These have now been corrected. Additionally, the authors would like to note that co-authors James P. Butler and Jeffrey J. Fredberg contributed equally to this Article; this change has now been made.

  14. Electronic and geometric structures of Ge{sub n}{sup -} and Ge{sub n}{sup +} (n=5-10) clusters in comparison with corresponding Si{sub n} ions

    Energy Technology Data Exchange (ETDEWEB)

    Li Baoxing; Cao Peilin; Song Bin; Ye Zhezhen

    2003-02-10

    Using full-potential linear-muffin-tin-orbital molecular-dynamics (FP-LMTO-MD) method, we have studied the geometric and electronic structures of ionic Ge{sub 5-10} clusters. Our calculations show that the ground state structures of some Ge cluster ions are different from those of their corresponding neutral Ge clusters. Furthermore, the positive Ge ions have more severe structural distortion than the negative Ge ions due to Jahn-Teller distortion. In addition, there are differences between the ground state structures of Ge ions and Si ions, although most of the Ge ions have similar geometrical configurations to their corresponding Si ions.

  15. The magnetic-distortion probe: velocimetry in conducting fluids.

    Science.gov (United States)

    Miralles, Sophie; Verhille, Gautier; Plihon, Nicolas; Pinton, Jean-François

    2011-09-01

    A new type of velocimeter, capable of local velocity measurements in conducting fluids, is introduced. The principle of the "magnetic-distortion probe" is based on the measurement of the induced magnetic field by the flow of a conducting fluid in the vicinity of a localized magnetic field. The new velocimeter has no moving parts, and can be enclosed in a sealed cap, easing the implementation in harsh environments, such as liquid metals. The proposed method allows one to probe both the continuous part and fluctuations of the velocity, the temporal and spatial resolution being linked to the actual geometric configuration of the probe. A prototype probe has been tested in a gallinstan pipe flow and in a fully turbulent flow of liquid gallium generated by the counter rotation of two coaxial impellers in a cylinder. The signals have been compared to a reference potential probe and show very good agreement both for time-averaged velocities and turbulent fluctuations. The prototype is shown to detect motion from a few cm s(-1) to a few m s(-1). Moreover, the use of the magnetic-distortion probe with large-scale applied magnetic field is discussed. © 2011 American Institute of Physics

  16. Gastric emptying measurements: delayed and complex emptying patterns without appropriate correction

    Energy Technology Data Exchange (ETDEWEB)

    Moore, J.G.; Christian, P.E.; Taylor, A.T.; Alazraki, N.

    1985-10-01

    Anteriorly acquired and geometric mean corrected gastric emptying curves of solids and liquid isotopic-labeled meals were compared in 37 subjects given 61 meals of three different sizes. Anterior data alone consistently and significantly underestimated solid-phase gastric emptying rates with all meal sizes when compared to geometric mean acquired data. However, with liquids there were only slight differences between anterior and anterior and posterior geometric mean corrected emptying-rates. The difference probably reflects greater attenuation of the 140 kev photon of /sup 99m/Tc compared to the 247 keV photon of In. With anterior data alone, an apparent early delay in emptying of solids was present with all meal sizes and the resultant emptying curves were nonlinear in shape. Geometric mean correction resulted in the linearization of the solid-phase emptying curves and essentially eliminated the apparent delay in emptying or lag phase noted with the anterior data alone. Based on our results, geometric mean correction techniques are necessary for accurate assessment of radioisotopic-labeled solid meals.

  17. [Study on phase correction method of spatial heterodyne spectrometer].

    Science.gov (United States)

    Wang, Xin-Qiang; Ye, Song; Zhang, Li-Juan; Xiong, Wei

    2013-05-01

    Phase distortion exists in collected interferogram because of a variety of measure reasons when spatial heterodyne spectrometers are used in practice. So an improved phase correction method is presented. The phase curve of interferogram was obtained through Fourier inverse transform to extract single side transform spectrum, based on which, the phase distortions were attained by fitting phase slope, so were the phase correction functions, and the convolution was processed between transform spectrum and phase correction function to implement spectrum phase correction. The method was applied to phase correction of actually measured monochromatic spectrum and emulational water vapor spectrum. Experimental results show that the low-frequency false signals in monochromatic spectrum fringe would be eliminated effectively to increase the periodicity and the symmetry of interferogram, in addition when the continuous spectrum imposed phase error was corrected, the standard deviation between it and the original spectrum would be reduced form 0.47 to 0.20, and thus the accuracy of spectrum could be improved.

  18. Landsat 8 Operational Land Imager On-Orbit Geometric Calibration and Performance

    Directory of Open Access Journals (Sweden)

    James Storey

    2014-11-01

    Full Text Available The Landsat 8 spacecraft was launched on 11 February 2013 carrying the Operational Land Imager (OLI payload for moderate resolution imaging in the visible, near infrared (NIR, and short-wave infrared (SWIR spectral bands. During the 90-day commissioning period following launch, several on-orbit geometric calibration activities were performed to refine the prelaunch calibration parameters. The results of these calibration activities were subsequently used to measure geometric performance characteristics in order to verify the OLI geometric requirements. Three types of geometric calibrations were performed including: (1 updating the OLI-to-spacecraft alignment knowledge; (2 refining the alignment of the sub-images from the multiple OLI sensor chips; and (3 refining the alignment of the OLI spectral bands. The aspects of geometric performance that were measured and verified included: (1 geolocation accuracy with terrain correction, but without ground control (L1Gt; (2 Level 1 product accuracy with terrain correction and ground control (L1T; (3 band-to-band registration accuracy; and (4 multi-temporal image-to-image registration accuracy. Using the results of the on-orbit calibration update, all aspects of geometric performance were shown to meet or exceed system requirements.

  19. Proof in geometry with "mistakes in geometric proofs"

    CERN Document Server

    Fetisov, A I

    2006-01-01

    This single-volume compilation of 2 books explores the construction of geometric proofs. It offers useful criteria for determining correctness and presents examples of faulty proofs that illustrate common errors. 1963 editions.

  20. Simulation and experimental study on distortion of butt and T-joints using WELD PLANNER

    International Nuclear Information System (INIS)

    Sulaiman, Mohd Shahar; Manurung, Yupiter HP; Rahim, Mohammad Ridzwan Abdul Mohd; Redza, Ridhwan; Lidam, Robert Ngendang Ak.; Abas, Sunhaji Kiyai; Tham, Ghalib; Haruman, Esa; Chau, Chan Yin

    2011-01-01

    This paper investigates the capability of linear thermal elastic numerical analysis to predict the welding distortion that occurs due to GMAW process. Distortion is considered as the major stumbling block that can adversely affect the dimensional accuracy and thus lead to expensive corrective work. Hence, forecast of distortion is crucially needed and ought to be determined in advance in order to minimize the negative effects, improve the quality of welded parts and finally to reduce the production costs. In this study, the welding deformation was simulated by using relatively new FEM software WELD PLANNER developed by ESI Group. This novel Welding Simulation Solution was employed to predict welding distortion induced in butt and T-joints with thickness of 4 mm. Low carbon steel material was used for the simulation and experimental study. A series of experiments using fully automated welding process were conducted for verification purpose to measure the distortion. By comparing between the simulation and experimental results, it was found out that this program code offered fast solution analysis time in estimating weld induced distortion within acceptable accuracy

  1. Simulation and experimental study on distortion of butt and T-joints using WELD PLANNER

    Energy Technology Data Exchange (ETDEWEB)

    Sulaiman, Mohd Shahar; Manurung, Yupiter HP; Rahim, Mohammad Ridzwan Abdul Mohd; Redza, Ridhwan; Lidam, Robert Ngendang Ak.; Abas, Sunhaji Kiyai; Tham, Ghalib [Universiti Teknologi MARA, Kuala Lumpur (Malaysia); Haruman, Esa [Bakrie University, Jakarta (Indonesia); Chau, Chan Yin [ESI Group, Kuala Lumpur (Malaysia)

    2011-10-15

    This paper investigates the capability of linear thermal elastic numerical analysis to predict the welding distortion that occurs due to GMAW process. Distortion is considered as the major stumbling block that can adversely affect the dimensional accuracy and thus lead to expensive corrective work. Hence, forecast of distortion is crucially needed and ought to be determined in advance in order to minimize the negative effects, improve the quality of welded parts and finally to reduce the production costs. In this study, the welding deformation was simulated by using relatively new FEM software WELD PLANNER developed by ESI Group. This novel Welding Simulation Solution was employed to predict welding distortion induced in butt and T-joints with thickness of 4 mm. Low carbon steel material was used for the simulation and experimental study. A series of experiments using fully automated welding process were conducted for verification purpose to measure the distortion. By comparing between the simulation and experimental results, it was found out that this program code offered fast solution analysis time in estimating weld induced distortion within acceptable accuracy.

  2. Geometric integrator for simulations in the canonical ensemble

    Energy Technology Data Exchange (ETDEWEB)

    Tapias, Diego, E-mail: diego.tapias@nucleares.unam.mx [Departamento de Física, Facultad de Ciencias, Universidad Nacional Autónoma de México, Ciudad Universitaria, Ciudad de México 04510 (Mexico); Sanders, David P., E-mail: dpsanders@ciencias.unam.mx [Departamento de Física, Facultad de Ciencias, Universidad Nacional Autónoma de México, Ciudad Universitaria, Ciudad de México 04510 (Mexico); Computer Science and Artificial Intelligence Laboratory, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, Massachusetts 02139 (United States); Bravetti, Alessandro, E-mail: alessandro.bravetti@iimas.unam.mx [Instituto de Investigaciones en Matemáticas Aplicadas y en Sistemas, Universidad Nacional Autónoma de México, Ciudad Universitaria, Ciudad de México 04510 (Mexico)

    2016-08-28

    We introduce a geometric integrator for molecular dynamics simulations of physical systems in the canonical ensemble that preserves the invariant distribution in equations arising from the density dynamics algorithm, with any possible type of thermostat. Our integrator thus constitutes a unified framework that allows the study and comparison of different thermostats and of their influence on the equilibrium and non-equilibrium (thermo-)dynamic properties of a system. To show the validity and the generality of the integrator, we implement it with a second-order, time-reversible method and apply it to the simulation of a Lennard-Jones system with three different thermostats, obtaining good conservation of the geometrical properties and recovering the expected thermodynamic results. Moreover, to show the advantage of our geometric integrator over a non-geometric one, we compare the results with those obtained by using the non-geometric Gear integrator, which is frequently used to perform simulations in the canonical ensemble. The non-geometric integrator induces a drift in the invariant quantity, while our integrator has no such drift, thus ensuring that the system is effectively sampling the correct ensemble.

  3. Geometric integrator for simulations in the canonical ensemble

    International Nuclear Information System (INIS)

    Tapias, Diego; Sanders, David P.; Bravetti, Alessandro

    2016-01-01

    We introduce a geometric integrator for molecular dynamics simulations of physical systems in the canonical ensemble that preserves the invariant distribution in equations arising from the density dynamics algorithm, with any possible type of thermostat. Our integrator thus constitutes a unified framework that allows the study and comparison of different thermostats and of their influence on the equilibrium and non-equilibrium (thermo-)dynamic properties of a system. To show the validity and the generality of the integrator, we implement it with a second-order, time-reversible method and apply it to the simulation of a Lennard-Jones system with three different thermostats, obtaining good conservation of the geometrical properties and recovering the expected thermodynamic results. Moreover, to show the advantage of our geometric integrator over a non-geometric one, we compare the results with those obtained by using the non-geometric Gear integrator, which is frequently used to perform simulations in the canonical ensemble. The non-geometric integrator induces a drift in the invariant quantity, while our integrator has no such drift, thus ensuring that the system is effectively sampling the correct ensemble.

  4. Measurement, analysis and correction of the closed orbit distortion ...

    Indian Academy of Sciences (India)

    2013-02-01

    Feb 1, 2013 ... quency (RF), linear coupling are being carried out. ..... Its guide tool is used to develop GUI for COD correction software. In addition ... rection software also has a feature to save all the parameters such as predicted/measured.

  5. Distortions Imposed By Inflation on Historical-Cost Depreciation

    OpenAIRE

    Bravo-Ureta, Boris E.

    1983-01-01

    The use of historical-cost depreciation in periods of persistent inflation decreases the present value of depreciation deductions, thus understating the true economic cost of capital and increasing the real after-tax rate of return required by potential investors. Efforts to correct these problems by adopting depreciation methods that allow for artificially short recovery periods or accelerated rates do not provide an adequate solution. Distortions imposed by inflation on historical-cost depr...

  6. Rate-distortion analysis of steganography for conveying stereovision disparity maps

    Science.gov (United States)

    Umeda, Toshiyuki; Batolomeu, Ana B. D. T.; Francob, Filipe A. L.; Delannay, Damien; Macq, Benoit M. M.

    2004-06-01

    3-D images transmission in a way which is compliant with traditional 2-D representations can be done through the embedding of disparity maps within the 2-D signal. This approach enables the transmission of stereoscopic video sequences or images on traditional analogue TV channels (PAL or NTSC) or printed photographic images. The aim of this work is to study the achievable performances of such a technique. The embedding of disparity maps has to be seen as a global rate-distortion problem. The embedding capacity through steganography is determined by the transmission channel noise and by the bearable distortion on the watermarked image. The distortion of the 3-D image displayed as two stereo views depends on the rate allocated to the complementary information required to build those two views from one reference 2-D image. Results from the works on the scalar Costa scheme are used to optimize the embedding of the disparity map compressed bit stream into the reference image. A method for computing the optimal trade off between the disparity map distortion and embedding distortion as a function of the channel impairments is proposed. The goal is to get a similar distortion on the left (the reference image) and the right (the disparity compensated image) images. We show that in typical situations the embedding of 2 bits/pixels in the left image, while the disparity map is compressed at 1 bit per pixel leads to a good trade-off. The disparity map is encoded with a strong error correcting code, including synchronisation bits.

  7. Geometric computations with interval and new robust methods applications in computer graphics, GIS and computational geometry

    CERN Document Server

    Ratschek, H

    2003-01-01

    This undergraduate and postgraduate text will familiarise readers with interval arithmetic and related tools to gain reliable and validated results and logically correct decisions for a variety of geometric computations plus the means for alleviating the effects of the errors. It also considers computations on geometric point-sets, which are neither robust nor reliable in processing with standard methods. The authors provide two effective tools for obtaining correct results: (a) interval arithmetic, and (b) ESSA the new powerful algorithm which improves many geometric computations and makes th

  8. Distortion-free diffusion MRI using an MRI-guided Tri-Cobalt 60 radiotherapy system: Sequence verification and preliminary clinical experience.

    Science.gov (United States)

    Gao, Yu; Han, Fei; Zhou, Ziwu; Cao, Minsong; Kaprealian, Tania; Kamrava, Mitchell; Wang, Chenyang; Neylon, John; Low, Daniel A; Yang, Yingli; Hu, Peng

    2017-10-01

    ) under the three orthogonal orientations. The detected errors were 0.474 ± 0.355 mm, 0.475 ± 0.287 mm, and 0.546 ± 0.336 mm in the axial, coronal, and sagittal plane. DW-ssEPI, however, failed the tests due to severe distortion and low signal intensity. Noise correction must be performed for the DW-ssEPI to avoid ADC quantitation errors, whereas it is optional for DP-TSE. At 0 °C, the two sequences provided accurate quantitation with < 3% variation with the reference. In the room temperature study, discrepancies between ADCs from DP-TSE and the reference were within 4%, but could be as high as 8% for DW-ssEPI after the noise correction. Excellent ADC reproducibility with a coefficient of variation < 5% was observed among the 10 measurements of DP-TSE, indicating desirable robustness for ADC-based tumor response assessment. In vivo TRE in DP-TSE was less than 1.6 mm overall, whereas it could be greater than 12 mm in DW-ssEPI. For GBM patients, the CSF and brain tissue ADCs from DP-TSE were within the ranges found in literature. ADC differences between the two techniques were within 8% among the six sarcoma patients. For the reference tube that had a relatively low diffusivity, the two diffusion sequences provided matched measurements. A diffusion technique with excellent geometric fidelity, accurate, and reproducible ADC measurement was demonstrated for longitudinal tumor response assessment using a low-field MRI-guided radiotherapy system. © 2017 American Association of Physicists in Medicine.

  9. Investigation of the 4D composite MR image distortion field associated with tumor motion for MR-guided radiotherapy.

    Science.gov (United States)

    Stanescu, T; Jaffray, D

    2016-03-01

    Magnetic resonance (MR) images are affected by geometric distortions due to the specifics of the MR scanner and patient anatomy. Quantifying the distortions associated with mobile tumors is particularly challenging due to real anatomical changes in the tumor's volume, shape, and relative location within the MR imaging volume. In this study, the authors investigate the 4D composite distortion field, which combines the effects of the susceptibility-induced and system-related distortion fields, experienced by mobile lung tumors. The susceptibility (χ) effects were numerically simulated for two specific scenarios: (a) a full motion cycle of a lung tumor due to breathing as depicted on ten phases of a 4D CBCT data set and (b) varying the tumor size and location in lung tissue via a synthetically generated sphere with variable diameter (4-80 mm). The χ simulation procedure relied on the segmentation and generation of 3D susceptibility (χ) masks and computation of the magnetic field by means of finite difference methods. A system-related distortion field, determined with a phantom and image processing algorithm, was used as a reference. The 4D composite distortion field was generated as the vector summation of the χ-induced and system-related fields. The analysis was performed for two orientations of the main magnetic field (B0), which correspond to several MRIgRT system configurations. Specifically, B0 was set along the z-axis as in the case of a cylindrical-bore scanner and in the (x,y)-plane as for a biplanar MR. Computations were also performed for a full revolution at 15° increments in the case of a rotating biplanar magnet. Histograms and metrics such as maximum, mean, and range were used to evaluate the characteristics of the 4D distortion field. The χ-induced field depends on the change in volume and shape of the moving tumor as well as the local surrounding anatomy. In the case of system-related distortions, the tumor experiences increased field

  10. On-line implant reconstruction in HDR brachytherapy

    International Nuclear Information System (INIS)

    Kolkman-Deurloo, Inger-Karine K.; Kruijf, Wilhelmus J.M. de; Levendag, Peter C.

    2006-01-01

    Background and purpose: To evaluate the accuracy of on-line planning in an Integrated Brachytherapy Unit (IBU) using dedicated image distortion correction algorithms, correcting the geometric distortion and magnetic distortion separately, and to determine the effect of the reconstruction accuracy on clinical treatment plans in terms of deviations in treatment time and dose. Patients and methods: The reconstruction accuracy has been measured using 20 markers, positioned at well known locations in a QA phantom. Treatment plans of two phantoms representing clinical implant geometries, have been compared with reference plans to determine the effect of the reconstruction accuracy on the treatment plan. Before clinical introduction, treatment plans of three representative patients, based on on-line reconstruction, have been compared with reference plans. Results: The average reconstruction error for 10 in. images reduces from -0.6 mm (range -2.6 to +1.0 mm) to -0.2 mm (range -1.2 to +0.6 mm) after image distortion correction and for 15 in. images from 0.8 mm (range -0.5 to +3.0 mm) to 0.0 mm (range -0.8 to +0.8 mm). The error in case of eccentric positioning of the phantom, i.e. 0.8 mm (range -1.0 to +3.3 mm), reduces to 0.1 mm (range -0.5 to +0.9 mm). Correction of the image distortions reduces the deviation in the calculated treatment time of maximally 2.7% to less than 0.8% in case of eccentrically positioned clinical phantoms. The deviation in the treatment time or reference dose in the plans based on on-line reconstruction with image distortion correction of the three patient examples is smaller than 0.3%. Conclusions: Accurate on-line implant reconstruction using the IBU localiser and dedicated correction algorithms separating the geometric distortion and the magnetic distortion is possible. The results fulfill the minimum requirements as imposed by the Netherlands Commission on Radiation Dosimetry (NCS) without limitations regarding the usable range of the field

  11. Geometrical effects in X-mode scattering

    International Nuclear Information System (INIS)

    Bretz, N.

    1986-10-01

    One technique to extend microwave scattering as a probe of long wavelength density fluctuations in magnetically confined plasmas is to consider the launching and scattering of extraordinary (X-mode) waves nearly perpendicular to the field. When the incident frequency is less than the electron cyclotron frequency, this mode can penetrate beyond the ordinary mode cutoff at the plasma frequency and avoid significant distortions from density gradients typical of tokamak plasmas. In the more familiar case, where the incident and scattered waves are ordinary, the scattering is isotropic perpendicular to the field. However, because the X-mode polarization depends on the frequency ratios and the ray angle to the magnetic field, the coupling between the incident and scattered waves is complicated. This geometrical form factor must be unfolded from the observed scattering in order to interpret the scattering due to density fluctuations alone. The geometrical factor is calculated here for the special case of scattering perpendicular to the magnetic field. For frequencies above the ordinary mode cutoff the scattering is relatively isotropic, while below cutoff there are minima in the forward and backward directions which go to zero at approximately half the ordinary mode cutoff density

  12. An Investigation on the Efficiency Correction Method of the Turbocharger at Low Speed

    Directory of Open Access Journals (Sweden)

    Jin Eun Chung

    2018-01-01

    Full Text Available The heat transfer in the turbocharger occurs due to the temperature difference between the exhaust gas and intake air, coolant, and oil. This heat transfer causes the efficiency of the compressor and turbine to be distorted, which is known to be exacerbated during low rotational speeds. Thus, this study proposes a method to mitigate the distortion of the test result data caused by heat transfer in the turbocharger. With this method, the representative compressor temperature is defined and the heat transfer rate of the compressor is calculated by considering the effect of the oil and turbine inlet temperatures at low rotation speeds, when the cold and the hot gas test are simultaneously performed. The correction of compressor efficiency, depending on the turbine inlet temperature, was performed through both hot and cold gas tests and the results showed a maximum of 16% error prior to correction and a maximum of 3% error after the correction. In addition, it shows that it is possible to correct the efficiency distortion of the turbocharger by heat transfer by correcting to the combined turbine efficiency based on the corrected compressor efficiency.

  13. Quadratic Regression-based Non-uniform Response Correction for Radiochromic Film Scanners

    International Nuclear Information System (INIS)

    Jeong, Hae Sun; Kim, Chan Hyeong; Han, Young Yih; Kum, O Yeon

    2009-01-01

    In recent years, several types of radiochromic films have been extensively used for two-dimensional dose measurements such as dosimetry in radiotherapy as well as imaging and radiation protection applications. One of the critical aspects in radiochromic film dosimetry is the accurate readout of the scanner without dose distortion. However, most of charge-coupled device (CCD) scanners used for the optical density readout of the film employ a fluorescent lamp or a coldcathode lamp as a light source, which leads to a significant amount of light scattering on the active layer of the film. Due to the effect of the light scattering, dose distortions are produced with non-uniform responses, although the dose is uniformly irradiated to the film. In order to correct the distorted doses, a method based on correction factors (CF) has been reported and used. However, the prediction of the real incident doses is difficult when the indiscreet doses are delivered to the film, since the dose correction with the CF-based method is restrictively used in case that the incident doses are already known. In a previous study, therefore, a pixel-based algorithm with linear regression was developed to correct the dose distortion of a flatbed scanner, and to estimate the initial doses. The result, however, was not very good for some cases especially when the incident dose is under approximately 100 cGy. In the present study, the problem was addressed by replacing the linear regression with the quadratic regression. The corrected doses using this method were also compared with the results of other conventional methods

  14. 'Distorted structure modelling' - a more physical approach to Rapid Distortion Theory

    International Nuclear Information System (INIS)

    Savill, A.M.

    1979-11-01

    Rapid Distortion Theory is reviewed in the light of the modern mechanistic approach to turbulent motion. The apparent failure of current models, based on this theory, to predict stress intensity ratios accurately in distorted shear flows is attributed to their oversimplistic assumptions concerning the inherent turbulence structure of such flows. A more realistic picture of this structure and the manner in which it responds to distortion is presented in terms of interactions between the mean flow and three principal types of eddies. If Rapid Distortion Theory is modified to account for this it is shown that the stress intensity ratios can be accurately predicted in three test flows. It is concluded that a computational scheme based on Rapid Distortion Theory might ultimately be capable of predicting turbulence parameters in the highly complex geometries of reactor cooling systems. (author)

  15. An efficient formulation for linear and geometric non-linear membrane elements

    Directory of Open Access Journals (Sweden)

    Mohammad Rezaiee-Pajand

    Full Text Available Utilizing the straingradient notation process and the free formulation, an efficient way of constructing membrane elements will be proposed. This strategy can be utilized for linear and geometric non-linear problems. In the suggested formulation, the optimization constraints of insensitivity to distortion, rotational invariance and not having parasitic shear error are employed. In addition, the equilibrium equations will be established based on some constraints among the strain states. The authors' technique can easily separate the rigid body motions, and those belong to deformational motions. In this article, a novel triangular element, named SST10, is formulated. This element will be used in several plane problems having irregular mesh and complicated geometry with linear and geometrically nonlinear behavior. The numerical outcomes clearly demonstrate the efficiency of the new formulation.

  16. Geometrization of quantum physics

    International Nuclear Information System (INIS)

    Ol'khov, O.A.

    2009-01-01

    It is shown that the Dirac equation for a free particle can be considered as a description of specific distortion of the space Euclidean geometry (space topological defect). This approach is based on the possibility of interpretation of the wave function as vector realizing representation of the fundamental group of the closed topological space-time 4-manifold. Mass and spin appear to be topological invariants. Such a concept explains all so-called 'strange' properties of quantum formalism: probabilities, wave-particle duality, nonlocal instantaneous correlation between noninteracting particles (EPR-paradox) and so on. Acceptance of the suggested geometrical concept means rejection of atomistic concept where all matter is considered as consisting of more and more small elementary particles. There are no any particles a priory, before measurement: the notions of particles appear as a result of classical interpretation of the contact of the region of the curved space with a device

  17. Geometrization of quantum physics

    Science.gov (United States)

    Ol'Khov, O. A.

    2009-12-01

    It is shown that the Dirac equation for free particle can be considered as a description of specific distortion of the space euclidean geometry (space topological defect). This approach is based on possibility of interpretation of the wave function as vector realizing representation of the fundamental group of the closed topological space-time 4-manifold. Mass and spin appear to be topological invariants. Such concept explains all so called “strange” properties of quantum formalism: probabilities, wave-particle duality, nonlocal instantaneous correlation between noninteracting particles (EPR-paradox) and so on. Acceptance of suggested geometrical concept means rejection of atomistic concept where all matter is considered as consisting of more and more small elementary particles. There is no any particles a priori, before measurement: the notions of particles appear as a result of classical interpretation of the contact of the region of the curved space with a device.

  18. Real-space post-processing correction of thermal drift and piezoelectric actuator nonlinearities in scanning tunneling microscope images

    Science.gov (United States)

    Yothers, Mitchell P.; Browder, Aaron E.; Bumm, Lloyd A.

    2017-01-01

    We have developed a real-space method to correct distortion due to thermal drift and piezoelectric actuator nonlinearities on scanning tunneling microscope images using Matlab. The method uses the known structures typically present in high-resolution atomic and molecularly resolved images as an internal standard. Each image feature (atom or molecule) is first identified in the image. The locations of each feature's nearest neighbors are used to measure the local distortion at that location. The local distortion map across the image is simultaneously fit to our distortion model, which includes thermal drift in addition to piezoelectric actuator hysteresis and creep. The image coordinates of the features and image pixels are corrected using an inverse transform from the distortion model. We call this technique the thermal-drift, hysteresis, and creep transform. Performing the correction in real space allows defects, domain boundaries, and step edges to be excluded with a spatial mask. Additional real-space image analyses are now possible with these corrected images. Using graphite(0001) as a model system, we show lattice fitting to the corrected image, averaged unit cell images, and symmetry-averaged unit cell images. Statistical analysis of the distribution of the image features around their best-fit lattice sites measures the aggregate noise in the image, which can be expressed as feature confidence ellipsoids.

  19. Real-space post-processing correction of thermal drift and piezoelectric actuator nonlinearities in scanning tunneling microscope images.

    Science.gov (United States)

    Yothers, Mitchell P; Browder, Aaron E; Bumm, Lloyd A

    2017-01-01

    We have developed a real-space method to correct distortion due to thermal drift and piezoelectric actuator nonlinearities on scanning tunneling microscope images using Matlab. The method uses the known structures typically present in high-resolution atomic and molecularly resolved images as an internal standard. Each image feature (atom or molecule) is first identified in the image. The locations of each feature's nearest neighbors are used to measure the local distortion at that location. The local distortion map across the image is simultaneously fit to our distortion model, which includes thermal drift in addition to piezoelectric actuator hysteresis and creep. The image coordinates of the features and image pixels are corrected using an inverse transform from the distortion model. We call this technique the thermal-drift, hysteresis, and creep transform. Performing the correction in real space allows defects, domain boundaries, and step edges to be excluded with a spatial mask. Additional real-space image analyses are now possible with these corrected images. Using graphite(0001) as a model system, we show lattice fitting to the corrected image, averaged unit cell images, and symmetry-averaged unit cell images. Statistical analysis of the distribution of the image features around their best-fit lattice sites measures the aggregate noise in the image, which can be expressed as feature confidence ellipsoids.

  20. Inclusion of geometric uncertainties in treatment plan evaluation

    NARCIS (Netherlands)

    van Herk, Marcel; Remeijer, Peter; Lebesque, Joos V.

    2002-01-01

    PURPOSE: To correctly evaluate realistic treatment plans in terms of absorbed dose to the clinical target volume (CTV), equivalent uniform dose (EUD), and tumor control probability (TCP) in the presence of execution (random) and preparation (systematic) geometric errors. MATERIALS AND METHODS: The

  1. Holographic measurement of distortion during laser melting: Additive distortion from overlapping pulses

    Science.gov (United States)

    Haglund, Peter; Frostevarg, Jan; Powell, John; Eriksson, Ingemar; Kaplan, Alexander F. H.

    2018-03-01

    Laser - material interactions such as welding, heat treatment and thermal bending generate thermal gradients which give rise to thermal stresses and strains which often result in a permanent distortion of the heated object. This paper investigates the thermal distortion response which results from pulsed laser surface melting of a stainless steel sheet. Pulsed holography has been used to accurately monitor, in real time, the out-of-plane distortion of stainless steel samples melted on one face by with both single and multiple laser pulses. It has been shown that surface melting by additional laser pulses increases the out of plane distortion of the sample without significantly increasing the melt depth. The distortion differences between the primary pulse and subsequent pulses has also been analysed for fully and partially overlapping laser pulses.

  2. Advanced Engineering Methods for Assessing Welding Distortion in Aero-Engine Assemblies

    International Nuclear Information System (INIS)

    Jackson, Kathryn; Darlington, Roger

    2011-01-01

    Welding remains an attractive fabrication method for aero-engine assemblies, offering high production rates and reduced total cost, particularly for large complex assemblies. However, distortion generated during the welding process continues to provide a major challenge in terms of the control of geometric tolerances and residual stress. The welding distortion is influenced by the sequence and position of joints, the clamping configuration and the design of the assembly. For large complex assemblies the range of these options may be large. Hence the use of numerical simulation at an early stage of the product development process is valuable to enable a wide range of these factors to be explored with the aim of minimising welding distortions before production commences, and thereby reducing the product development time. In this paper, a new technique for simulation of welding distortions based on a shrinkage analysis is evaluated for an aero-engine assembly. The shrinkage simulations were built and solved using the ESI Group software Weld Planner. The rapid simulation speed enabled a wide range of welding plans to be explored, leading to recommendations for the fabrication process. The sensitivity of the model to mesh size and material properties is reported. The results of the shrinkage analysis were found to be similar to those of a transient analysis generated using ESI Group software SysWeld. The solution times were found to be significantly lower for the shrinkage analysis than the transient analysis. Hence it has been demonstrated that shrinkage analysis is a valuable tool for exploring the fabrication process of a welded assembly at an early stage of the product development process.

  3. Determination of main geometric parameters of stereo-television equipment for radiation image representation

    International Nuclear Information System (INIS)

    Mamchev, G.V.

    1985-01-01

    Geometric distortions of the three-dimensional image of objects under testing are analyzed, quantitative values of stereovision zone depth, depth resolution are determined. It has been found that the potential depth of stereovision zone in a stereo-television unit should be established according to physiological peculiarities of perception of the observer. Dimensions of the stereovision zone in case of reproduction of orthoscopic images are larger than in case of pseudoscopic imaging at which the degree of geometric deformations of the three-dimensional image is considerably less. The most effective method of increasing the depth resolution of the stereo-X ray television unit consists in increasing the resolution of its separate elements, in the first turn, of the fluorescent screen or image converter

  4. Geometric mean IELT and premature ejaculation: appropriate statistics to avoid overestimation of treatment efficacy

    NARCIS (Netherlands)

    Waldinger, Marcel D.; Zwinderman, Aeilko H.; Olivier, Berend; Schweitzer, Dave H.

    2008-01-01

    INTRODUCTION: The intravaginal ejaculation latency time (IELT) behaves in a skewed manner and needs the appropriate statistics for correct interpretation of treatment results. AIMS: To explain the rightful use of geometrical mean IELT values and the fold increase of the geometric mean IELT because

  5. Oceanic Loading and Local Distortions at the Baksan, Russia, and Gran Sasso, Italy, Strain Stations

    Science.gov (United States)

    Milyukov, V. K.; Amoruso, A.; Crescentini, L.; Mironov, A. P.; Myasnikov, A. V.; Lagutkina, A. V.

    2018-03-01

    Reliable use of strain data in geophysical studies requires their preliminary correction for ocean loading and various local distortions. These effects, in turn, can be estimated from the tidal records which are contributed by solid and oceanic loading. In this work, we estimate the oceanic tidal loading at two European strain stations (Baksan, Russia, and Gran Sasso, Italy) by analyzing the results obtained with the different Earth and ocean models. The influence of local distortions on the strain measurements at the two stations is estimated.

  6. Purely geometric path integral for spin-foams

    International Nuclear Information System (INIS)

    Shirazi, Atousa Chaharsough; Engle, Jonathan

    2014-01-01

    Spin-foams are a proposal for defining the dynamics of loop quantum gravity via path integral. In order for a path integral to be at least formally equivalent to the corresponding canonical quantization, at each point in the space of histories it is important that the integrand have not only the correct phase—a topic of recent focus in spin-foams—but also the correct modulus, usually referred to as the measure factor. The correct measure factor descends from the Liouville measure on the reduced phase space, and its calculation is a task of canonical analysis. The covariant formulation of gravity from which spin-foams are derived is the Plebanski–Holst formulation, in which the basic variables are a Lorentz connection and a Lorentz-algebra valued 2-form, called the Plebanski 2-form. However, in the final spin-foam sum, one usually sums over only spins and intertwiners, which label eigenstates of the Plebanski 2-form alone. The spin-foam sum is therefore a discretized version of a Plebanski–Holst path integral in which only the Plebanski 2-form appears, and in which the connection degrees of freedom have been integrated out. We call this a purely geometric Plebanski–Holst path integral. In prior work in which one of the authors was involved, the measure factor for the Plebanski–Holst path integral with both connection and 2-form variables was calculated. Before one discretizes this measure and incorporates it into a spin-foam sum, however, one must integrate out the connection in order to obtain the purely geometric version of the path integral. To calculate this purely geometric path integral is the principal task of the present paper, and it is done in two independent ways. Background independence of the resulting path integral is discussed in the final section, and gauge-fixing is discussed in appendix B. (paper)

  7. On chromatic and geometrical calibration

    DEFF Research Database (Denmark)

    Folm-Hansen, Jørgen

    1999-01-01

    The main subject of the present thesis is different methods for the geometrical and chromatic calibration of cameras in various environments. For the monochromatic issues of the calibration we present the acquisition of monochrome images, the classic monochrome aberrations and the various sources...... the correct interpolation method is described. For the chromatic issues of calibration we present the acquisition of colour and multi-spectral images, the chromatic aberrations and the various lens/camera based non-uniformities of the illumination of the image plane. It is described how the monochromatic...... to design calibration targets for both geometrical and chromatic calibration are described. We present some possible systematical errors on the detection of the objects in the calibration targets, if viewed in a non orthogonal angle, if the intensities are uneven or if the image blurring is uneven. Finally...

  8. Failure of geometric electromagnetism in the adiabatic vector Kepler problem

    International Nuclear Information System (INIS)

    Anglin, J.R.; Schmiedmayer, J.

    2004-01-01

    The magnetic moment of a particle orbiting a straight current-carrying wire may precess rapidly enough in the wire's magnetic field to justify an adiabatic approximation, eliminating the rapid time dependence of the magnetic moment and leaving only the particle position as a slow degree of freedom. To zeroth order in the adiabatic expansion, the orbits of the particle in the plane perpendicular to the wire are Keplerian ellipses. Higher-order postadiabatic corrections make the orbits precess, but recent analysis of this 'vector Kepler problem' has shown that the effective Hamiltonian incorporating a postadiabatic scalar potential ('geometric electromagnetism') fails to predict the precession correctly, while a heuristic alternative succeeds. In this paper we resolve the apparent failure of the postadiabatic approximation, by pointing out that the correct second-order analysis produces a third Hamiltonian, in which geometric electromagnetism is supplemented by a tensor potential. The heuristic Hamiltonian of Schmiedmayer and Scrinzi is then shown to be a canonical transformation of the correct adiabatic Hamiltonian, to second order. The transformation has the important advantage of removing a 1/r 3 singularity which is an artifact of the adiabatic approximation

  9. Flow distortion on boom mounted cup anemometers

    DEFF Research Database (Denmark)

    Lindelöw, Per Jonas Petter; Friis Pedersen, Troels; Gottschall, Julia

    In this report we investigate on wind direction dependent errors in the measurement of the horizontal wind speed by boom mounted cup anemometers. The boom mounting on the studied lattice tower is performed according to IEC standard design rules, yet, larger deviations than predicted by flow models...... are observed. The errors on the measurements are likely caused by an underestimation of the flow distortions around the tower. In this paper an experimental method for deriving a correction formula and an in-field calibration is suggested. The method is based on measurements with two cup anemometers mounted...

  10. Outline of an ultracorrector compensating for all primary chromatic and geometrical aberrations of charged-particle lenses

    International Nuclear Information System (INIS)

    Rose, Harald

    2004-01-01

    A novel ultracorrector is outlined which compensates for the primary and secondary first-order chromatic aberrations and all third-order geometrical aberrations of electron optical systems with a straight axis. Owing to the imposed symmetry conditions on the fields and the paraxial fundamental rays, the corrector does not introduce aberrations with 2-fold symmetry. The chromatic aberrations are corrected by means of crossed electric magnetic quadrupoles while the third-order geometrical aberrations are eliminated by octopoles. By placing these elements at distinct positions within the corrector, it is possible to successively eliminate the third-order aberrations in such a way that each subsequent correction does not affect the aberrations corrected in the preceding correction steps

  11. Correction of vertical dispersion and betatron coupling for the CLIC damping ring

    CERN Document Server

    Korostelev, M S

    2006-01-01

    The sensitivity of the CLIC damping ring to various kinds of alignment errors has been studied. Without any correction, fairly small vertical misalignments of the quadrupoles and, in particular, the sextupoles, introduce unacceptable distortions of the closed orbit as well as intolerable spurious vertical dispersion and coupling due to the strong focusing optics of the damping ring. A sophisticated beam-based correction scheme has been developed to bring the design target emittances and the dynamic aperture back to the ideal value. The correction using dipolar correctors and several skew quadrupole correctors allows a minimization of the closed-orbit distortion, the cross-talk between vertical and horizontal closed orbits, the residual vertical dispersion and the betatron coupling.

  12. The development of MOSA-II multichannel optical spectrum analyzer

    International Nuclear Information System (INIS)

    Guo Li; Yang Zhoujing; Fang Shuyao

    1989-01-01

    The MOSA-II Multichannel Optical Spectrum Analyzer is a high-perfor mance, easy-to-use measurment system for extremely rapid spectral data acquistion, processing and presentation. It consists of four parts: vidicon, data acquiring and timing circuit, the correcting circuit for the geometric distortion and the non-uniform distortion of the vidicon, IBMPC/XT and color plotter. The system has the following functions: single spectrum acquisition, continuous acquisition of multi-spectra, noise reduction, math, operations (including addition, subtraction, multiplication, and division) and geometric transform action of the spectra, and 3D-presentation of the spectra on both the color screen and the plotter. The absolute sensitivity of the system is 18 Photons/sec · mm 2 . The access time for data acquisition is 64 μs/per channel and the spectrum range is 1800 A - 8000A, the geometric distortion<2%, the amplitude error<5%

  13. Multi-shape pulse pile-up correction: The MCPPU code

    International Nuclear Information System (INIS)

    Sabbatucci, Lorenzo; Scot, Viviana; Fernandez, Jorge E.

    2014-01-01

    In spectroscopic measurements with high counting rate, pulse pile-up (PPU) is a common distortion of the spectrum. It is fully ascribable to the pulse handling circuitry of the detector and it is not comprised in the detector response function which is well explained by a purely physical model. Since PPU occurs after the transport inside the detector, this is the first correction to perform in case of spectrum unfolding. Many producers include electronic rejection circuits to limit the appearance of PPU, but it is never suppressed completely. Therefore, it is always necessary to correct PPU distortions after the measurement. In the present work, it is described the post-processing tool MCPPU (Monte Carlo Pulse Pile-Up), based on the MC algorithm developed by Guo et al. (2004, 2005). MCPPU automatically determines the dead time of the counting system and corrects for PPU effects even in the presence of electronic suppression. The capability of allowing a user defined pulse shape makes the code suitable to be used with any kind of detector. The features of MCPPU are illustrated with some examples. - Highlights: • Pulse pile-up (PPU) is a common distortion in radiation detection. • MCPPU is a Monte Carlo code to perform post-processing PPU correction. • MCPPU evaluates automatically the dead time to use in the pile-up recovery. • The measured pulse shape can be introduced as a normalized discrete distribution. • MCPPU is compatible with detectors using electronic rejection circuitry

  14. Geometric model from microscopic theory for nuclear absorption

    International Nuclear Information System (INIS)

    John, S.; Townsend, L.W.; Wilson, J.W.; Tripathi, R.K.

    1993-07-01

    A parameter-free geometric model for nuclear absorption is derived herein from microscopic theory. The expression for the absorption cross section in the eikonal approximation, taken in integral form, is separated into a geometric contribution that is described by an energy-dependent effective radius and two surface terms that cancel in an asymptotic series expansion. For collisions of light nuclei, an expression for the effective radius is derived from harmonic oscillator nuclear density functions. A direct extension to heavy nuclei with Woods-Saxon densities is made by identifying the equivalent half-density radius for the harmonic oscillator functions. Coulomb corrections are incorporated, and a simplified geometric form of the Bradt-Peters type is obtained. Results spanning the energy range from 1 MeV/nucleon to 1 GeV/nucleon are presented. Good agreement with experimental results is obtained

  15. Geometric model for nuclear absorption from microscopic theory

    International Nuclear Information System (INIS)

    John, S.; Townsend, L.W.; Wilson, J.W.; Tripathi, R.K.

    1993-01-01

    A parameter-free geometric model for nuclear absorption is derived from microscopic theory. The expression for the absorption cross section in the eikonal approximation taken in integral form is separated into a geometric contribution, described by an energy-dependent effective radius, and two surface terms which are shown to cancel in an asymptotic series expansion. For collisions of light nuclei, an expression for the effective radius is derived using harmonic-oscillator nuclear density functions. A direct extension to heavy nuclei with Woods-Saxon densities is made by identifying the equivalent half density radius for the harmonic-oscillator functions. Coulomb corrections are incorporated and a simplified geometric form of the Bradt-Peters type obtained. Results spanning the energy range of 1 MeV/nucleon to 1 GeV/nucleon are presented. Good agreement with experimental results is obtained

  16. Stress measurement in thin films by geometrical optics

    Science.gov (United States)

    Rossnagel, S. M.; Gilstrap, P.; Rujkorakarn, R.

    1982-01-01

    A variation of Newton's rings experiment is proposed for measuring film stress. The procedure described, the geometrical optics method, is used to measure radii of curvature for a series of film depositions with Ta, Al, and Mo films. The method has a sensitivity of 1 x 10 to the 9th dyn/sq cm, corresponding to the practical radius limit of about 50 m, and a repeatability usually within five percent. For the purposes of comparison, radii are also measured by Newton's rings method and the Talysurf method; all results are found to be in general agreement. Measurement times are also compared: the geometrical optics method requires only 1/2-1 minute. It is concluded that the geometrical optics method provides an inexpensive, fast, and a reasonably correct technique with which to measure stresses in film.

  17. Lyapunov vs. geometrical stability analysis of the Kepler and the restricted three body problems

    International Nuclear Information System (INIS)

    Yahalom, A.; Levitan, J.; Lewkowicz, M.; Horwitz, L.

    2011-01-01

    In this Letter we show that although the application of standard Lyapunov analysis predicts that completely integrable Kepler motion is unstable, the geometrical analysis of Horwitz et al. predicts the observed stability. This seems to us to provide evidence for both the incompleteness of the standard Lyapunov analysis and the strength of the geometrical analysis. Moreover, we apply this approach to the three body problem in which the third body is restricted to move on a circle of large radius which induces an adiabatic time dependent potential on the second body. This causes the second body to move in a very interesting and intricate but periodic trajectory; however, the standard Lyapunov analysis, as well as methods based on the parametric variation of curvature associated with the Jacobi metric, incorrectly predict chaotic behavior. The geometric approach predicts the correct stable motion in this case as well. - Highlights: → Lyapunov analysis predicts Kepler motion to be unstable. → Geometrical analysis predicts the observed stability. → Lyapunov analysis predicts chaotic behavior in restricted three body problem. → The geometric approach predicts the correct stable motion in restricted three body problem.

  18. Hybrid wavefront sensing and image correction algorithm for imaging through turbulent media

    Science.gov (United States)

    Wu, Chensheng; Robertson Rzasa, John; Ko, Jonathan; Davis, Christopher C.

    2017-09-01

    It is well known that passive image correction of turbulence distortions often involves using geometry-dependent deconvolution algorithms. On the other hand, active imaging techniques using adaptive optic correction should use the distorted wavefront information for guidance. Our work shows that a hybrid hardware-software approach is possible to obtain accurate and highly detailed images through turbulent media. The processing algorithm also takes much fewer iteration steps in comparison with conventional image processing algorithms. In our proposed approach, a plenoptic sensor is used as a wavefront sensor to guide post-stage image correction on a high-definition zoomable camera. Conversely, we show that given the ground truth of the highly detailed image and the plenoptic imaging result, we can generate an accurate prediction of the blurred image on a traditional zoomable camera. Similarly, the ground truth combined with the blurred image from the zoomable camera would provide the wavefront conditions. In application, our hybrid approach can be used as an effective way to conduct object recognition in a turbulent environment where the target has been significantly distorted or is even unrecognizable.

  19. Limited distortion in LSB steganography

    Science.gov (United States)

    Kim, Younhee; Duric, Zoran; Richards, Dana

    2006-02-01

    It is well known that all information hiding methods that modify the least significant bits introduce distortions into the cover objects. Those distortions have been utilized by steganalysis algorithms to detect that the objects had been modified. It has been proposed that only coefficients whose modification does not introduce large distortions should be used for embedding. In this paper we propose an effcient algorithm for information hiding in the LSBs of JPEG coefficients. Our algorithm uses parity coding to choose the coefficients whose modifications introduce minimal additional distortion. We derive the expected value of the additional distortion as a function of the message length and the probability distribution of the JPEG quantization errors of cover images. Our experiments show close agreement between the theoretical prediction and the actual additional distortion.

  20. Life Science-Related Physics Laboratory on Geometrical Optics

    Science.gov (United States)

    Edwards, T. H.; And Others

    1975-01-01

    Describes a laboratory experiment on geometrical optics designed for life science majors in a noncalculus introductory physics course. The thin lens equation is used by the students to calculate the focal length of the lens necessary to correct a myopic condition in an optical bench simulation of a human eye. (Author/MLH)

  1. Distortion Effects on Trojan Horse Applications

    International Nuclear Information System (INIS)

    Pizzone, R. G.; Spitaleri, C.; La Cognata, M.; Lamia, L.; Romano, S.; Mukhamedzhanov, A. M.; Blokhintsev, L. D.; Bertulani, C. A.; Irgaziev, B. F.

    2011-01-01

    The widths of the spectator momentum distributions in several nuclei, which have been used as Trojan Horses, have been obtained as a function of the transferred momentum. Applications of Trojan Horse method will also be discussed. The study of processes relevant for astrophysics involving light nuclei has increased in the last decades due to the development of indirect methods. The present paper will also help to point out the distortion effects which arise at low energies in the study of three-body processes and will suggest some way to by-pass them in Trojan Horse Method (THM) applications. The goal of this paper is to compare the experimental momentum distribution of the spectator in the bound state a = (sx) extracted from the 2 → 3 particles (breakup, or breakup with rearrangement) reactions with the theoretical one. The theoretical momentum distribution has been calculated for the target a = (sx) using the Hulthen potential for a = d and Woods-Saxon one with the standard geometrical parameters, radius r 0 = 1.25 fm and diffuseness a = 0.65 fm, for other nuclei. (author)

  2. The Dark Side of Context: Context Reinstatement Can Distort Memory.

    Science.gov (United States)

    Doss, Manoj K; Picart, Jamila K; Gallo, David A

    2018-04-01

    It is widely assumed that context reinstatement benefits memory, but our experiments revealed that context reinstatement can systematically distort memory. Participants viewed pictures of objects superimposed over scenes, and we later tested their ability to differentiate these old objects from similar new objects. Context reinstatement was manipulated by presenting objects on the reinstated or switched scene at test. Not only did context reinstatement increase correct recognition of old objects, but it also consistently increased incorrect recognition of similar objects as old ones. This false recognition effect was robust, as it was found in several experiments, occurred after both immediate and delayed testing, and persisted with high confidence even after participants were warned to avoid the distorting effects of context. To explain this memory illusion, we propose that context reinstatement increases the likelihood of confusing conceptual and perceptual information, potentially in medial temporal brain regions that integrate this information.

  3. Studies of field distortions in a time projection chamber for the International Linear Collider

    International Nuclear Information System (INIS)

    Zenker, Klaus

    2014-12-01

    The International Linear Collider (ILC) will allow to do precision measurements of Standard Model parameter and to search for new physics. The ILD detector concept, which is developed for the ILC, uses a Time Projection Chamber (TPC) as central tracking device. The momentum resolution goal for the ILD TPC is δ(1/p t ) ≅ 10 -4 (GeV/c) -1 at a magnetic field of B=3.5 T. Field distortions of the magnetic or electric field inside the sensitive volume of the TPC distort the momentum measurements. Therefore, one needs to keep them under control and correct them with high precision. In this thesis the main sources of field distortions in the TPC are identified and their effects are determined. Furthermore, possibilities to reduce the identified field distortions are presented. One known source of distortions of the electric field are ions, produced by the gas amplification in the TPC anode, that drift into the sensitive volume of the TPC. In the first part of this work the creation of these ions in Gas Electron Multiplier (GEM), which are used for the gas amplification, is studied. It will be shown that the resulting field distortions are not acceptable at the ILD TPC. By tuning the parameters of the gas amplification at the anode the field distortion can be reduced, which is shown in measurements and simulations. In addition measurements using a modified GEM show that it is possible to further reduce the field distortions with such a GEM. In the second part of this work field distortions arising at boundaries between individual readout modules are investigated using simulation studies. It will be shown in simulations, which are verified by measurement results, that these field distortions significantly influence the readout module performance. Based on the simulation results the GEM based readout module developed at DESY is optimised and the field distortions are reduced. These performance improvements could also be verified in measurements. Finally, a laser

  4. Analysis of slippery droplet on tilted plate by development of optical correction method

    Science.gov (United States)

    Ko, Han Seo; Gim, Yeonghyeon; Choi, Sung Ho; Jang, Dong Kyu; Sohn, Dong Kee

    2017-11-01

    Because of distortion effects on a surface of a sessile droplet, the inner flow field of the droplet is measured by a PIV (particle image velocimetry) method with low reliability. In order to solve this problem, many researchers have studied and developed the optical correction method. However, the method cannot be applied for various cases such as the tilted droplet or other asymmetric shaped droplets since most methods were considered only for the axisymmetric shaped droplets. For the optical correction of the asymmetric shaped droplet, the surface function was calculated by the three-dimensional reconstruction using the ellipse curve fitting method. Also, the optical correction using the surface function was verified by the numerical simulation. Then, the developed method was applied to reconstruct the inner flow field of the droplet on the tilted plate. The colloidal droplet of water on the tilted surface was used, and the distorted effect on the surface of the droplet was calculated. Using the obtained results and the PIV method, the corrected flow field for the inner and interface parts of the droplet was reconstructed. Consequently, the error caused by the distortion effect of the velocity vector located on the apex of the droplet was removed. National Research Foundation (NRF) of Korea, (2016R1A2B4011087).

  5. Simulation Study on Multipassed Welding Distortion of Combined Joint Types using Thermo-Elastic-Plastic FEM

    Directory of Open Access Journals (Sweden)

    RN Lidam

    2012-12-01

    Full Text Available This paper investigates the angular distortion induced by the gas metal arc welding (GMAW process on the combined butt and T-joint with a thickness of 9 mm. The material used in this study was low manganese carbon steel S355J2G3. A 2-D and 3-D thermo-elastic-plastic finite element (FE analysis has been developed to simulate the induced distortion of multipassed welding. In this research, SYSWELD 2010 with its computation management tool, known as multipassed welding advisor (MPA, was applied to analyze the distortion behavior of combined joint types. To model the heat source of GMAW, Goldak's double ellipsoid representation, which is available within this finite element analysis (FEA code was selected. Prior to the results discussion, this paper also shows the step-bystep procedures to simulate combined jointing which begins with metallurgical and customized heat source modeling, and is followed by creating geometrical mesh using Visual-Mesh 6.5 for analyzing and processing the results. Apart from 2-D and 3-D comparison analysis, the final objective of this research is also aimed to be a baseline study to provide preliminary information in preparing the tools and equipment for experimental investigation.

  6. Analysis of Brown camera distortion model

    Science.gov (United States)

    Nowakowski, Artur; Skarbek, Władysław

    2013-10-01

    Contemporary image acquisition devices introduce optical distortion into image. It results in pixel displacement and therefore needs to be compensated for many computer vision applications. The distortion is usually modeled by the Brown distortion model, which parameters can be included in camera calibration task. In this paper we describe original model, its dependencies and analyze orthogonality with regard to radius for its decentering distortion component. We also report experiments with camera calibration algorithm included in OpenCV library, especially a stability of distortion parameters estimation is evaluated.

  7. Traditional vectors as an introduction to geometric algebra

    International Nuclear Information System (INIS)

    Carroll, J E

    2003-01-01

    The 2002 Oersted Medal Lecture by David Hestenes concerns the many advantages for education in physics if geometric algebra were to replace standard vector algebra. However, such a change has difficulties for those who have been taught traditionally. A new way of introducing geometric algebra is presented here using a four-element array composed of traditional vector and scalar products. This leads to an explicit 4 x 4 matrix representation which contains key requirements for three-dimensional geometric algebra. The work can be extended to include Maxwell's equations where it is found that curl and divergence appear naturally together. However, to obtain an explicit representation of space-time algebra with the correct behaviour under Lorentz transformations, an 8 x 8 matrix representation has to be formed. This leads to a Dirac representation of Maxwell's equations showing that space-time algebra has hidden within its formalism the symmetry of 'parity, charge conjugation and time reversal'

  8. Breathing mode distortion and magnetic order in rare-earth nickelates RNiO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Hampel, Alexander; Ederer, Claude [Materials Theory, ETH Zuerich (Switzerland)

    2016-07-01

    Rare-earth nickelate perovskites display a rich and not yet fully understood phase diagram, where all RNiO{sub 3} compounds with R from Sm to Lu undergo a non-magnetic metal-insulator transition (MIT). This transition is connected to a lattice distortion, which can be described as breathing mode of the oxygen octahedra surrounding the Ni cations. Between 100-250 K the RNiO{sub 3} compounds undergo a magnetic transition to an antiferromagnetic (AFM) state, with a wave-vector k= [(1)/(4) (1)/(4) (1)/(4)] relative to the underlying simple cubic perovskite structure. Here, we use density functional theory and its extensions (DFT+U, DFT+DMFT) together with distortion mode analysis to explore the interplay between lattice distortions, magnetic order, and the strength of the local Coulomb interaction U in rare earth nickelates. Our results show a strong dependency of the breathing mode amplitude on the magnetic order, with a much larger breathing mode obtained for the AFM state compared to the ferromagnetic case. Furthermore, we demonstrate that DFT+U is able to capture the correct trends of the lattice distortions across the nickelate series.

  9. The data correction algorithms in sup 6 sup 0 Co train inspection system

    CERN Document Server

    Yuan Ya Ding; LiuXiMing; Miao Ji Cheng

    2002-01-01

    Because of the physical characteristics of the sup 6 sup 0 Co train inspection system and the application of high-speed data collection system based on current integral, the original images have been distorted in a certain degree. Authors investigate into the reasons why the distortion comes into being, and accordingly present the data correction algorithm

  10. The γ-ray self-absorption correction for sources with random geometrical shape

    International Nuclear Information System (INIS)

    Lu Xiangdong

    2003-01-01

    The regularities followed by γ-ray self-absorption corrections of nuclear materials under common geometry conditions have been studied by the numeric simulation. Many models were adopted. The results show that the self-absorption corrections are not related to shape and size of the sources. The method is succinct, and the conclusions are useful for actual situation and offer bases for data analyzing. The component of a sample is analyzed by means of the self-absorption correction

  11. A geometric measure of dark energy with pairs of galaxies.

    Science.gov (United States)

    Marinoni, Christian; Buzzi, Adeline

    2010-11-25

    Observations indicate that the expansion of the Universe is accelerating, which is attributed to a ‘dark energy’ component that opposes gravity. There is a purely geometric test of the expansion of the Universe (the Alcock–Paczynski test), which would provide an independent way of investigating the abundance (Ω(X)) and equation of state (W(X)) of dark energy. It is based on an analysis of the geometrical distortions expected from comparing the real-space and redshift-space shape of distant cosmic structures, but it has proved difficult to implement. Here we report an analysis of the symmetry properties of distant pairs of galaxies from archival data. This allows us to determine that the Universe is flat. By alternately fixing its spatial geometry at Ω(k)≡0 and the dark energy equation-of-state parameter at W(X)≡-1, and using the results of baryon acoustic oscillations, we can establish at the 68.3% confidence level that and -0.85>W(X)>-1.12 and 0.60<Ω(X)<0.80.

  12. Baseline distortion effect on gamma-ray pulse-height spectra in neutron capture experiments

    International Nuclear Information System (INIS)

    Laptev, A.; Harada, H.; Nakamura, S.; Hori, J.; Igashira, M.; Ohsaki, T.; Ohgama, K.

    2005-01-01

    A baseline distortion effect due to gamma-flash at neutron time-of-flight measurement using a pulse neutron source has been investigated. Pulses from C 6 D 6 detectors accumulated by flash-ADC were processed with both standard analog-to-digital converter (ADC) and flash-ADC operational modes. A correction factor of gamma-ray yields, due to baseline shift, was quantitatively obtained by comparing the pulse height spectra of the two data-taking modes. The magnitude of the correction factor depends on the time after gamma-flash and has complex time dependence with a changing sign

  13. Improved remote gaze estimation using corneal reflection-adaptive geometric transforms

    Science.gov (United States)

    Ma, Chunfei; Baek, Seung-Jin; Choi, Kang-A.; Ko, Sung-Jea

    2014-05-01

    Recently, the remote gaze estimation (RGE) technique has been widely applied to consumer devices as a more natural interface. In general, the conventional RGE method estimates a user's point of gaze using a geometric transform, which represents the relationship between several infrared (IR) light sources and their corresponding corneal reflections (CRs) in the eye image. Among various methods, the homography normalization (HN) method achieves state-of-the-art performance. However, the geometric transform of the HN method requiring four CRs is infeasible for the case when fewer than four CRs are available. To solve this problem, this paper proposes a new RGE method based on three alternative geometric transforms, which are adaptive to the number of CRs. Unlike the HN method, the proposed method not only can operate with two or three CRs, but can also provide superior accuracy. To further enhance the performance, an effective error correction method is also proposed. By combining the introduced transforms with the error-correction method, the proposed method not only provides high accuracy and robustness for gaze estimation, but also allows for a more flexible system setup with a different number of IR light sources. Experimental results demonstrate the effectiveness of the proposed method.

  14. Interplay between Peptide Bond Geometrical Parameters in Nonglobular Structural Contexts

    Directory of Open Access Journals (Sweden)

    Luciana Esposito

    2013-01-01

    Full Text Available Several investigations performed in the last two decades have unveiled that geometrical parameters of protein backbone show a remarkable variability. Although these studies have provided interesting insights into one of the basic aspects of protein structure, they have been conducted on globular and water-soluble proteins. We report here a detailed analysis of backbone geometrical parameters in nonglobular proteins/peptides. We considered membrane proteins and two distinct fibrous systems (amyloid-forming and collagen-like peptides. Present data show that in these systems the local conformation plays a major role in dictating the amplitude of the bond angle N-Cα-C and the propensity of the peptide bond to adopt planar/nonplanar states. Since the trends detected here are in line with the concept of the mutual influence of local geometry and conformation previously established for globular and water-soluble proteins, our analysis demonstrates that the interplay of backbone geometrical parameters is an intrinsic and general property of protein/peptide structures that is preserved also in nonglobular contexts. For amyloid-forming peptides significant distortions of the N-Cα-C bond angle, indicative of sterical hidden strain, may occur in correspondence with side chain interdigitation. The correlation between the dihedral angles Δω/ψ in collagen-like models may have interesting implications for triple helix stability.

  15. Interplay between peptide bond geometrical parameters in nonglobular structural contexts.

    Science.gov (United States)

    Esposito, Luciana; Balasco, Nicole; De Simone, Alfonso; Berisio, Rita; Vitagliano, Luigi

    2013-01-01

    Several investigations performed in the last two decades have unveiled that geometrical parameters of protein backbone show a remarkable variability. Although these studies have provided interesting insights into one of the basic aspects of protein structure, they have been conducted on globular and water-soluble proteins. We report here a detailed analysis of backbone geometrical parameters in nonglobular proteins/peptides. We considered membrane proteins and two distinct fibrous systems (amyloid-forming and collagen-like peptides). Present data show that in these systems the local conformation plays a major role in dictating the amplitude of the bond angle N-C(α)-C and the propensity of the peptide bond to adopt planar/nonplanar states. Since the trends detected here are in line with the concept of the mutual influence of local geometry and conformation previously established for globular and water-soluble proteins, our analysis demonstrates that the interplay of backbone geometrical parameters is an intrinsic and general property of protein/peptide structures that is preserved also in nonglobular contexts. For amyloid-forming peptides significant distortions of the N-C(α)-C bond angle, indicative of sterical hidden strain, may occur in correspondence with side chain interdigitation. The correlation between the dihedral angles Δω/ψ in collagen-like models may have interesting implications for triple helix stability.

  16. Virtual machining considering dimensional, geometrical and tool deflection errors in three-axis CNC milling machines

    OpenAIRE

    Soori, Mohsen; Arezoo, Behrooz; Habibi, Mohsen

    2014-01-01

    Virtual manufacturing systems can provide useful means for products to be manufactured without the need of physical testing on the shop floor. As a result, the time and cost of part production can be decreased. There are different error sources in machine tools such as tool deflection, geometrical deviations of moving axis and thermal distortions of machine tool structures. Some of these errors can be decreased by controlling the machining process and environmental parameters. However other e...

  17. Virtual machining considering dimensional, geometrical and tool deflection errors in three-axis CNC milling machines

    OpenAIRE

    Soori, Mohsen; Arezoo, Behrooz; Habibi, Mohsen

    2016-01-01

    Virtual manufacturing systems can provide useful means for products to be manufactured without the need of physical testing on the shop floor. As a result, the time and cost of part production can be decreased. There are different error sources in machine tools such as tool deflection, geometrical deviations of moving axis and thermal distortions of machine tool structures. Some of these errors can be decreased by controlling the machining process and environmental parameters. However other e...

  18. Cognitive Distortions, Humor Styles, and Depression.

    Science.gov (United States)

    Rnic, Katerina; Dozois, David J A; Martin, Rod A

    2016-08-01

    Cognitive distortions are negative biases in thinking that are theorized to represent vulnerability factors for depression and dysphoria. Despite the emphasis placed on cognitive distortions in the context of cognitive behavioural theory and practice, a paucity of research has examined the mechanisms through which they impact depressive symptomatology. Both adaptive and maladaptive styles of humor represent coping strategies that may mediate the relation between cognitive distortions and depressive symptoms. The current study examined the correlations between the frequency and impact of cognitive distortions across both social and achievement-related contexts and types of humor. Cognitive distortions were associated with reduced use of adaptive Affiliative and Self-Enhancing humor styles and increased use of maladaptive Aggressive and Self-Defeating humor. Reduced use of Self-Enhancing humor mediated the relationship between most types of cognitive distortions and depressed mood, indicating that distorted negative thinking may interfere with an individual's ability to adopt a humorous and cheerful outlook on life (i.e., use Self-Enhancing humor) as a way of regulating emotions and coping with stress, thereby resulting in elevated depressive symptoms. Similarly, Self-Defeating humor mediated the association of the social impact of cognitive distortions with depression, such that this humor style may be used as a coping strategy for dealing with distorted thinking that ultimately backfires and results in increased dysphoria.

  19. Distortion Control during Welding

    NARCIS (Netherlands)

    Akbari Pazooki, A.M.

    2014-01-01

    The local material expansion and contraction involved in welding result in permanent deformations or instability i.e., welding distortion. Considerable efforts have been made in controlling welding distortion prior to, during or after welding. Thermal Tensioning (TT) describes a group of in-situ

  20. Equation-Method for correcting clipping errors in OFDM signals.

    Science.gov (United States)

    Bibi, Nargis; Kleerekoper, Anthony; Muhammad, Nazeer; Cheetham, Barry

    2016-01-01

    Orthogonal frequency division multiplexing (OFDM) is the digital modulation technique used by 4G and many other wireless communication systems. OFDM signals have significant amplitude fluctuations resulting in high peak to average power ratios which can make an OFDM transmitter susceptible to non-linear distortion produced by its high power amplifiers (HPA). A simple and popular solution to this problem is to clip the peaks before an OFDM signal is applied to the HPA but this causes in-band distortion and introduces bit-errors at the receiver. In this paper we discuss a novel technique, which we call the Equation-Method, for correcting these errors. The Equation-Method uses the Fast Fourier Transform to create a set of simultaneous equations which, when solved, return the amplitudes of the peaks before they were clipped. We show analytically and through simulations that this method can, correct all clipping errors over a wide range of clipping thresholds. We show that numerical instability can be avoided and new techniques are needed to enable the receiver to differentiate between correctly and incorrectly received frequency-domain constellation symbols.

  1. A novel scheme for automatic nonrigid image registration using deformation invariant feature and geometric constraint

    Science.gov (United States)

    Deng, Zhipeng; Lei, Lin; Zhou, Shilin

    2015-10-01

    Automatic image registration is a vital yet challenging task, particularly for non-rigid deformation images which are more complicated and common in remote sensing images, such as distorted UAV (unmanned aerial vehicle) images or scanning imaging images caused by flutter. Traditional non-rigid image registration methods are based on the correctly matched corresponding landmarks, which usually needs artificial markers. It is a rather challenging task to locate the accurate position of the points and get accurate homonymy point sets. In this paper, we proposed an automatic non-rigid image registration algorithm which mainly consists of three steps: To begin with, we introduce an automatic feature point extraction method based on non-linear scale space and uniform distribution strategy to extract the points which are uniform distributed along the edge of the image. Next, we propose a hybrid point matching algorithm using DaLI (Deformation and Light Invariant) descriptor and local affine invariant geometric constraint based on triangulation which is constructed by K-nearest neighbor algorithm. Based on the accurate homonymy point sets, the two images are registrated by the model of TPS (Thin Plate Spline). Our method is demonstrated by three deliberately designed experiments. The first two experiments are designed to evaluate the distribution of point set and the correctly matching rate on synthetic data and real data respectively. The last experiment is designed on the non-rigid deformation remote sensing images and the three experimental results demonstrate the accuracy, robustness, and efficiency of the proposed algorithm compared with other traditional methods.

  2. Correction of chromatic and geometric aberrations using sextupoles and octupoles

    International Nuclear Information System (INIS)

    Colton, E.

    1978-01-01

    The procedure for applying some chromatic corrections to a final transport line, neglecting space charge, utilizing the method suggested by Brown is described. The possibility of including octupoles into a point-to-point triplet system, as outlined by Fenster is studied. Positive results were obtained in both cases: (i) using 2 + I correcting sections with two pairs of non-interlaced sextupoles increased the fraction of beam with ΔP/P = 1% onto a 0.1 cm radius target by more than a factor of 1.75; (ii) six octupoles placed into a point-to-point triplet system increased the fraction of a full emittance ΔP/P = 0% beam striking a 0.1 cm radius target by a factor of 2.5

  3. On distortions of TPC coordinates: inhomogeneities of electric and magnetic field

    CERN Document Server

    Dydak, F

    2003-01-01

    After a general discussion of electron drift in a gas volume with electric and magnetic fields, distortions in the r and r phi coordinates arising from inhomogeneities of the electric and magnetic fields in the HARP TPC are calculated. Inhomogeneities of the electric field arise from i) positive ions released by cosmic rays, ii) positive ions released by interaction secondaries, iii) positive ions released by beam muons, iv) positive ions released from beam particles downstream of the inner field cage, and v) a high voltage misalignment between the outer and inner field cages. Also, distortions arising from the inhomogeneity of the magnetic field are calculated. These effects resolve the controversy on unphysical numbers of 'wrong-charge' TPC tracks. The bad news are that effects are too big to be neglected. The good news are that, with enough sweat and tears, they can be adequately corrected.

  4. Different partial volume correction methods lead to different conclusions

    DEFF Research Database (Denmark)

    Greve, Douglas N; Salat, David H; Bowen, Spencer L

    2016-01-01

    A cross-sectional group study of the effects of aging on brain metabolism as measured with (18)F-FDG-PET was performed using several different partial volume correction (PVC) methods: no correction (NoPVC), Meltzer (MZ), Müller-Gärtner (MG), and the symmetric geometric transfer matrix (SGTM) usin...

  5. Frequency modulation television analysis: Distortion analysis

    Science.gov (United States)

    Hodge, W. H.; Wong, W. H.

    1973-01-01

    Computer simulation is used to calculate the time-domain waveform of standard T-pulse-and-bar test signal distorted in passing through an FM television system. The simulator includes flat or preemphasized systems and requires specification of the RF predetection filter characteristics. The predetection filters are modeled with frequency-symmetric Chebyshev (0.1-db ripple) and Butterworth filters. The computer was used to calculate distorted output signals for sixty-four different specified systems, and the output waveforms are plotted for all sixty-four. Comparison of the plotted graphs indicates that a Chebyshev predetection filter of four poles causes slightly more signal distortion than a corresponding Butterworth filter and the signal distortion increases as the number of poles increases. An increase in the peak deviation also increases signal distortion. Distortion also increases with the addition of preemphasis.

  6. A new digitized reverse correction method for hypoid gears based on a one-dimensional probe

    Science.gov (United States)

    Li, Tianxing; Li, Jubo; Deng, Xiaozhong; Yang, Jianjun; Li, Genggeng; Ma, Wensuo

    2017-12-01

    In order to improve the tooth surface geometric accuracy and transmission quality of hypoid gears, a new digitized reverse correction method is proposed based on the measurement data from a one-dimensional probe. The minimization of tooth surface geometrical deviations is realized from the perspective of mathematical analysis and reverse engineering. Combining the analysis of complex tooth surface generation principles and the measurement mechanism of one-dimensional probes, the mathematical relationship between the theoretical designed tooth surface, the actual machined tooth surface and the deviation tooth surface is established, the mapping relation between machine-tool settings and tooth surface deviations is derived, and the essential connection between the accurate calculation of tooth surface deviations and the reverse correction method of machine-tool settings is revealed. Furthermore, a reverse correction model of machine-tool settings is built, a reverse correction strategy is planned, and the minimization of tooth surface deviations is achieved by means of the method of numerical iterative reverse solution. On this basis, a digitized reverse correction system for hypoid gears is developed by the organic combination of numerical control generation, accurate measurement, computer numerical processing, and digitized correction. Finally, the correctness and practicability of the digitized reverse correction method are proved through a reverse correction experiment. The experimental results show that the tooth surface geometric deviations meet the engineering requirements after two trial cuts and one correction.

  7. Growing geometric reasoning in solving problems of analytical geometry through the mathematical communication problems to state Islamic university students

    Science.gov (United States)

    Mujiasih; Waluya, S. B.; Kartono; Mariani

    2018-03-01

    Skills in working on the geometry problems great needs of the competence of Geometric Reasoning. As a teacher candidate, State Islamic University (UIN) students need to have the competence of this Geometric Reasoning. When the geometric reasoning in solving of geometry problems has grown well, it is expected the students are able to write their ideas to be communicative for the reader. The ability of a student's mathematical communication is supposed to be used as a marker of the growth of their Geometric Reasoning. Thus, the search for the growth of geometric reasoning in solving of analytic geometry problems will be characterized by the growth of mathematical communication abilities whose work is complete, correct and sequential, especially in writing. Preceded with qualitative research, this article was the result of a study that explores the problem: Was the search for the growth of geometric reasoning in solving analytic geometry problems could be characterized by the growth of mathematical communication abilities? The main activities in this research were done through a series of activities: (1) Lecturer trains the students to work on analytic geometry problems that were not routine and algorithmic process but many problems that the process requires high reasoning and divergent/open ended. (2) Students were asked to do the problems independently, in detail, complete, order, and correct. (3) Student answers were then corrected each its stage. (4) Then taken 6 students as the subject of this research. (5) Research subjects were interviewed and researchers conducted triangulation. The results of this research, (1) Mathematics Education student of UIN Semarang, had adequate the mathematical communication ability, (2) the ability of this mathematical communication, could be a marker of the geometric reasoning in solving of problems, and (3) the geometric reasoning of UIN students had grown in a category that tends to be good.

  8. A simulation study of linear coupling effects and their correction in RHIC

    International Nuclear Information System (INIS)

    Parzen, G.

    1992-11-01

    This paper describes a possible skew quadrupole correction system for linear coupling for the RHIC92 lattice. A simulation study has been done for the correction system. Results are given for the performance of the correction system, and the required strength of the skew quadruple correctors. An important effect of linear coupling in RHIC is to shift the tune ν x ν y , sometimes called tune splitting. Most of this tune splitting can be corrected with a two family skew quadrupole correction system. For RHIC92, the same 2 family correction system will work for all likely choices of β*. This was not the case for the RHIC91 lattice where different families of correctors were needed for different β*. The tune splitting described above which is corrected with a 2 family correction system is driven primarily by the ν x - ν y harmonic of the skew quadrupole field given by the field multipole αl. There are several other effects of linear coupling present which are driven primarily by the ν x + ν y harmonics of the skew quadrupole field, αl. These include the following: (1) A higher order residual tune shift that remains after correction with the 2 family correction system. This tune shift is roughly quadratic in αl; (2) Possible large changes in the beta functions; (3) Possible increase in the beam size at injection due to the beta function distortion and the emittance distortion at injection

  9. Volterra Filtering for ADC Error Correction

    Directory of Open Access Journals (Sweden)

    J. Saliga

    2001-09-01

    Full Text Available Dynamic non-linearity of analog-to-digital converters (ADCcontributes significantly to the distortion of digitized signals. Thispaper introduces a new effective method for compensation such adistortion based on application of Volterra filtering. Considering ana-priori error model of ADC allows finding an efficient inverseVolterra model for error correction. Efficiency of proposed method isdemonstrated on experimental results.

  10. [Correction of light refraction and reflection in medical transmission optical tomography].

    Science.gov (United States)

    Tereshchenko, S A; Potapov, D A

    2002-01-01

    The effects of light refraction and reflection on the quality of image reconstruction in medical transmission optical tomography of high-scattering media are considered. It has been first noted that light refraction not only distorts the geometric scheme of measurements, but may lead to the appearance of object areas that cannot be scanned. Some ways of decreasing the effect of refraction on the reconstruction of spatial distribution of the extinction coefficient are stated.

  11. Impact of the MLC on the MRI field distortion of a prototype MRI-linac

    International Nuclear Information System (INIS)

    Kolling, Stefan; Keall, Paul; Oborn, Brad

    2013-01-01

    generally smaller in the perpendicular beam orientation. The peak-to-peak DSV distortion was below 300 μT at SID≥130 cm (perpendicular) and SID≥140 cm (inline) for the 1.0 T design. (4) The simulation of different treatment fields was identified to cause dynamic changes in the field distribution. However, the estimated residual distortion was below 1.2 mm geometric distortion at SID≥120 cm (perpendicular) and SID≥130 cm (inline) for a 10 mT/m frequency-encoding gradient. (5) Due to magnetic saturation of the MLC materials, the field distortion remained constant at B 0 >1.0 T.Conclusions: This work shows that the MRI field distortions caused by the MLC cannot be ignored and must be thoroughly investigated for any MRI-linac system. The numeric distortion values obtained for our 1.0 T magnet may vary for other magnet designs with substantially different fringe fields, however the concept of modest increases in the SID to reduce the distortion to a shimmable level is generally applicable

  12. Methods for Geometric Data Validation of 3d City Models

    Science.gov (United States)

    Wagner, D.; Alam, N.; Wewetzer, M.; Pries, M.; Coors, V.

    2015-12-01

    Geometric quality of 3D city models is crucial for data analysis and simulation tasks, which are part of modern applications of the data (e.g. potential heating energy consumption of city quarters, solar potential, etc.). Geometric quality in these contexts is however a different concept as it is for 2D maps. In the latter case, aspects such as positional or temporal accuracy and correctness represent typical quality metrics of the data. They are defined in ISO 19157 and should be mentioned as part of the metadata. 3D data has a far wider range of aspects which influence their quality, plus the idea of quality itself is application dependent. Thus, concepts for definition of quality are needed, including methods to validate these definitions. Quality on this sense means internal validation and detection of inconsistent or wrong geometry according to a predefined set of rules. A useful starting point would be to have correct geometry in accordance with ISO 19107. A valid solid should consist of planar faces which touch their neighbours exclusively in defined corner points and edges. No gaps between them are allowed, and the whole feature must be 2-manifold. In this paper, we present methods to validate common geometric requirements for building geometry. Different checks based on several algorithms have been implemented to validate a set of rules derived from the solid definition mentioned above (e.g. water tightness of the solid or planarity of its polygons), as they were developed for the software tool CityDoctor. The method of each check is specified, with a special focus on the discussion of tolerance values where they are necessary. The checks include polygon level checks to validate the correctness of each polygon, i.e. closeness of the bounding linear ring and planarity. On the solid level, which is only validated if the polygons have passed validation, correct polygon orientation is checked, after self-intersections outside of defined corner points and edges

  13. Geometrical tuning art for entirely subwavelength grating waveguide based integrated photonics circuits.

    Science.gov (United States)

    Wang, Zheng; Xu, Xiaochuan; Fan, Donglei; Wang, Yaguo; Subbaraman, Harish; Chen, Ray T

    2016-05-05

    Subwavelength grating (SWG) waveguide is an intriguing alternative to conventional optical waveguides due to the extra degree of freedom it offers in tuning a few important waveguide properties, such as dispersion and refractive index. Devices based on SWG waveguides have demonstrated impressive performances compared to conventional waveguides. However, the high loss of SWG waveguide bends jeopardizes their applications in integrated photonic circuits. In this work, we propose a geometrical tuning art, which realizes a pre-distorted refractive index profile in SWG waveguide bends. The pre-distorted refractive index profile can effectively reduce the mode mismatch and radiation loss simultaneously, thus significantly reduce the bend loss. This geometry tuning art has been numerically optimized and experimentally demonstrated in present study. Through such tuning, the average insertion loss of a 5 μm SWG waveguide bend is reduced drastically from 5.43 dB to 1.10 dB per 90° bend for quasi-TE polarization. In the future, the proposed scheme will be utilized to enhance performance of a wide range of SWG waveguide based photonics devices.

  14. A GEOMETRICAL HEIGHT SCALE FOR SUNSPOT PENUMBRAE

    International Nuclear Information System (INIS)

    Puschmann, K. G.; Ruiz Cobo, B.; MartInez Pillet, V.

    2010-01-01

    Inversions of spectropolarimetric observations of penumbral filaments deliver the stratification of different physical quantities in an optical depth scale. However, without establishing a geometrical height scale, their three-dimensional geometrical structure cannot be derived. This is crucial in understanding the correct spatial variation of physical properties in the penumbral atmosphere and to provide insights into the mechanism capable of explaining the observed penumbral brightness. The aim of this work is to determine a global geometrical height scale in the penumbra by minimizing the divergence of the magnetic field vector and the deviations from static equilibrium as imposed by a force balance equation that includes pressure gradients, gravity, and the Lorentz force. Optical depth models are derived from the inversion of spectropolarimetric data of an active region observed with the Solar Optical Telescope on board the Hinode satellite. We use a genetic algorithm to determine the boundary condition for the inference of geometrical heights. The retrieved geometrical height scale permits the evaluation of the Wilson depression at each pixel and the correlation of physical quantities at each height. Our results fit into the uncombed penumbral scenario, i.e., a penumbra composed of flux tubes with channeled mass flow and with a weaker and more horizontal magnetic field as compared with the background field. The ascending material is hotter and denser than their surroundings. We do not find evidence of overturning convection or field-free regions in the inner penumbral area analyzed. The penumbral brightness can be explained by the energy transfer of the ascending mass carried by the Evershed flow, if the physical quantities below z = -75 km are extrapolated from the results of the inversion.

  15. Guessing and compression subject to distortion

    OpenAIRE

    Hanawal, Manjesh Kumar; Sundaresan, Rajesh

    2010-01-01

    The problem of guessing a random string is revisited. The relation-ship between guessing without distortion and compression is extended to the case when source alphabet size is countably in¯nite. Further, similar relationship is established for the case when distortion allowed by establishing a tight relationship between rate distortion codes and guessing strategies.

  16. An Improved Distortion Operator for Insurance Risks

    Institute of Scientific and Technical Information of China (English)

    GAO Jian-wei; QIU Wan-hua

    2002-01-01

    This paper reviews the distortion function approach developed in the actuarial literature for insurance risks. The main aim of this paper is to derive an extensive distortion operator, and to propose a new premium principle based on this extensive distortion operator. Furthermore, the non-robustness of general distortion operator is also discussed. Examples are provided using Bernoulli, Pareto, Lognormal and Gamma distribution assumptions.

  17. Volterra Series Based Distortion Effect

    DEFF Research Database (Denmark)

    Agerkvist, Finn T.

    2010-01-01

    A large part of the characteristic sound of the electric guitar comes from nonlinearities in the signal path. Such nonlinearities may come from the input- or output-stage of the amplier, which is often equipped with vacuum tubes or a dedicated distortion pedal. In this paper the Volterra series...... expansion for non linear systems is investigated with respect to generating good distortion. The Volterra series allows for unlimited adjustment of the level and frequency dependency of each distortion component. Subjectively relevant ways of linking the dierent orders are discussed....

  18. TU-AB-BRA-07: Distortion-Free 3D Diffusion MRI On An MRI-Guided Radiotherapy System for Longitudinal Tumor Response Assessment

    International Nuclear Information System (INIS)

    Gao, Y; Yang, Y; Rangwala, N; Cao, M; Low, D; Hu, P

    2016-01-01

    Purpose: To develop a reliable, 3D distortion-free diffusion MRI technique for longitudinal tumor response assessment and MRI-guided adaptive radiotherapy(RT). Methods: A diffusion prepared 3D turbo spin echo readout (DP-TSE) sequence was developed and compared with the conventional diffusion-weighted single-shot echo-planar-imaging (DW-ssEPI) sequence in a commercially available diffusion phantom, and one head-and-neck and one brain cancer patient on an MRI-guided RT system (ViewRay). In phantom study, the geometric fidelity was quantified as the ratio between the left-right (RL) and anterior-posterior (AP) dimension. Ten slices were measured on DP-TSE, DW-ssEPI and standard TSE images where the later was used as the geometric reference. ADC accuracy was verified at both 0°C (reference ADC available) and room temperature with a range of diffusivity between 0.35 and 2.0*10"−"3mm"2/s. The ADC reproducibility was assessed based on 8 room-temperature measurements on 6 different days. In the pilot single-slice in-vivo study, CT images were used as the geometric reference, and ADC maps from both diffusion sequences were compared. Results: Distortion and susceptive-related artifact were severe in DW-ssEPI, with significantly lower RL/AP ratio (0.9579±0.0163) than DP-TSE (0.9990±0.0031) and TSE (0.9995±0.0031). ADCs from the two diffusion sequences both matched well with the vendor-provided values at 0°C; however DW-ssEPI fails to provide accurate ADC for high diffusivity vials at room temperature due to high noise level (10 times higher than DP-TSE). The DP-TSE sequence had excellent ADC reproducibility with <4% ADC variation among 8 separate measurements. In patient study, DP-TSE exhibited substantially improved geometric reliability. ROI analysis in ADC maps generated from DP-TSE and DW-ssEPI showed <5% difference where high b-value images were excluded from the latter approach due to excessive noise level. Conclusion: A diffusion MRI sequence with excellent

  19. TU-AB-BRA-07: Distortion-Free 3D Diffusion MRI On An MRI-Guided Radiotherapy System for Longitudinal Tumor Response Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Y; Yang, Y; Rangwala, N; Cao, M; Low, D; Hu, P [UCLA School of Medicine, Los Angeles, CA (United States)

    2016-06-15

    Purpose: To develop a reliable, 3D distortion-free diffusion MRI technique for longitudinal tumor response assessment and MRI-guided adaptive radiotherapy(RT). Methods: A diffusion prepared 3D turbo spin echo readout (DP-TSE) sequence was developed and compared with the conventional diffusion-weighted single-shot echo-planar-imaging (DW-ssEPI) sequence in a commercially available diffusion phantom, and one head-and-neck and one brain cancer patient on an MRI-guided RT system (ViewRay). In phantom study, the geometric fidelity was quantified as the ratio between the left-right (RL) and anterior-posterior (AP) dimension. Ten slices were measured on DP-TSE, DW-ssEPI and standard TSE images where the later was used as the geometric reference. ADC accuracy was verified at both 0°C (reference ADC available) and room temperature with a range of diffusivity between 0.35 and 2.0*10{sup −3}mm{sup 2}/s. The ADC reproducibility was assessed based on 8 room-temperature measurements on 6 different days. In the pilot single-slice in-vivo study, CT images were used as the geometric reference, and ADC maps from both diffusion sequences were compared. Results: Distortion and susceptive-related artifact were severe in DW-ssEPI, with significantly lower RL/AP ratio (0.9579±0.0163) than DP-TSE (0.9990±0.0031) and TSE (0.9995±0.0031). ADCs from the two diffusion sequences both matched well with the vendor-provided values at 0°C; however DW-ssEPI fails to provide accurate ADC for high diffusivity vials at room temperature due to high noise level (10 times higher than DP-TSE). The DP-TSE sequence had excellent ADC reproducibility with <4% ADC variation among 8 separate measurements. In patient study, DP-TSE exhibited substantially improved geometric reliability. ROI analysis in ADC maps generated from DP-TSE and DW-ssEPI showed <5% difference where high b-value images were excluded from the latter approach due to excessive noise level. Conclusion: A diffusion MRI sequence with

  20. Deferred slanted-edge analysis: a unified approach to spatial frequency response measurement on distorted images and color filter array subsets.

    Science.gov (United States)

    van den Bergh, F

    2018-03-01

    The slanted-edge method of spatial frequency response (SFR) measurement is usually applied to grayscale images under the assumption that any distortion of the expected straight edge is negligible. By decoupling the edge orientation and position estimation step from the edge spread function construction step, it is shown in this paper that the slanted-edge method can be extended to allow it to be applied to images suffering from significant geometric distortion, such as produced by equiangular fisheye lenses. This same decoupling also allows the slanted-edge method to be applied directly to Bayer-mosaicked images so that the SFR of the color filter array subsets can be measured directly without the unwanted influence of demosaicking artifacts. Numerical simulation results are presented to demonstrate the efficacy of the proposed deferred slanted-edge method in relation to existing methods.

  1. Geometric mean IELT and premature ejaculation: appropriate statistics to avoid overestimation of treatment efficacy.

    Science.gov (United States)

    Waldinger, Marcel D; Zwinderman, Aeilko H; Olivier, Berend; Schweitzer, Dave H

    2008-02-01

    The intravaginal ejaculation latency time (IELT) behaves in a skewed manner and needs the appropriate statistics for correct interpretation of treatment results. To explain the rightful use of geometrical mean IELT values and the fold increase of the geometric mean IELT because of the positively skewed IELT distribution. Linking theoretical arguments to the outcome of several selective serotonin reuptake inhibitor and modern antidepressant study results. Geometric mean IELT and fold increase of geometrical mean IELT. Log-transforming each separate IELT measurement of each individual man is the basis for the calculation of the geometric mean IELT. A drug-induced positively skewed IELT distribution necessitates the calculation of the geometric mean IELTs at baseline and during drug treatment. In a positively skewed IELT distribution, the use of the "arithmetic" mean IELT risks an overestimation of the drug-induced ejaculation delay as the mean IELT is always higher than the geometric mean IELT. Strong ejaculation-delaying drugs give rise to a strong positively skewed IELT distribution, whereas weak ejaculation-delaying drugs give rise to (much) less skewed IELT distributions. Ejaculation delay is expressed in fold increase of the geometric mean IELT. Drug-induced ejaculatory performance discloses a positively skewed IELT distribution, requiring the use of the geometric mean IELT and the fold increase of the geometric mean IELT.

  2. Optimization of a novel large field of view distortion phantom for MR-only treatment planning.

    Science.gov (United States)

    Price, Ryan G; Knight, Robert A; Hwang, Ken-Pin; Bayram, Ersin; Nejad-Davarani, Siamak P; Glide-Hurst, Carri K

    2017-07-01

    MR-only treatment planning requires images of high geometric fidelity, particularly for large fields of view (FOV). However, the availability of large FOV distortion phantoms with analysis software is currently limited. This work sought to optimize a modular distortion phantom to accommodate multiple bore configurations and implement distortion characterization in a widely implementable solution. To determine candidate materials, 1.0 T MR and CT images were acquired of twelve urethane foam samples of various densities and strengths. Samples were precision-machined to accommodate 6 mm diameter paintballs used as landmarks. Final material candidates were selected by balancing strength, machinability, weight, and cost. Bore sizes and minimum aperture width resulting from couch position were tabulated from the literature (14 systems, 5 vendors). Bore geometry and couch position were simulated using MATLAB to generate machine-specific models to optimize the phantom build. Previously developed software for distortion characterization was modified for several magnet geometries (1.0 T, 1.5 T, 3.0 T), compared against previously published 1.0 T results, and integrated into the 3D Slicer application platform. All foam samples provided sufficient MR image contrast with paintball landmarks. Urethane foam (compressive strength ∼1000 psi, density ~20 lb/ft 3 ) was selected for its accurate machinability and weight characteristics. For smaller bores, a phantom version with the following parameters was used: 15 foam plates, 55 × 55 × 37.5 cm 3 (L×W×H), 5,082 landmarks, and weight ~30 kg. To accommodate > 70 cm wide bores, an extended build used 20 plates spanning 55 × 55 × 50 cm 3 with 7,497 landmarks and weight ~44 kg. Distortion characterization software was implemented as an external module into 3D Slicer's plugin framework and results agreed with the literature. The design and implementation of a modular, extendable distortion phantom was optimized for several bore

  3. Logarithmic corrections to gravitational entropy and the null energy condition

    Energy Technology Data Exchange (ETDEWEB)

    Parikh, Maulik, E-mail: maulik.parikh@asu.edu; Svesko, Andrew

    2016-10-10

    Using a relation between the thermodynamics of local horizons and the null energy condition, we consider the effects of quantum corrections to the gravitational entropy. In particular, we find that the geometric form of the null energy condition is not affected by the inclusion of logarithmic corrections to the Bekenstein–Hawking entropy.

  4. Magnetic field perturbation in proton MR imaging - A study of a contrast agent and of distortions due to metallic implants

    International Nuclear Information System (INIS)

    Olsson, M.

    1992-01-01

    Perturbations of the static magnetic field in proton MR imaging (NMR imaging, MRI, MRT) result in image distortion and/or signal loss. An investigation of a superparamagnetic contrast agent for MR imaging has been performed. Magnetite particles were embedded in biodegradable starch spheres with a diameter of one micrometer. Animal experiments showed that the agent was quickly accumulated in the reticulo-endothelial system (RES), causing a decrease in signal intensity in this region. Diffusion within the locally generated magnetic field perturbation is responsible for signal loss in spin-echo images. Furthermore, the magnetic properties of various aneurysm clips were investigated to determine which clips could be used safely in a clinical MR investigation. MR artifacts caused by the metallic clips were studied using a geometric phantom. Non-ferromagnetic clips were concluded to be safe for examinations with medium field (0.3 tesla) MR imaging systems. A comparison study between MR and CT was performed on patients harbouring intracranial, nonferromagnetic aneurysm clips. The artifacts close to the clips were equally serve for MR and CT, but at some distance, the MR images were much less affected than the CT images. Finally, a computer program capable of simulating any realistic MR imaging situation has been developed. Raw data matrices are obtained by solving the Bloch equations. Corrections for intravascular spin behaviour have been implemented together with efficient algorithms. A quantitative investigation of signal displacement and signal loss, caused by small metallic implants, has been performed by computer simulation. An exact expression for the magnetic field outside a homogeneous ellipsoid in an external magnetic field has been derived. Distortions in MR images, caused by perturbing ellipsoids of different shapes and orientations, were studied. (30 refs.) (au)

  5. An X-ray wave theory for heavily distorted crystals. 1

    International Nuclear Information System (INIS)

    Ohkawa, T.; Hashimoto, H.

    1985-01-01

    An X-ray diffraction theory is developed of monochromatic waves having spherical wave front, which is applicable to an interpretation of divergent X-ray diffraction images of crystals containing arbitral types of strain field. The theory is divided into two parts. In part I, Takagi's theory is expanded by introducing amplitude and phase correction functions and a new improved representation for the X-ray diffraction theory is given. In part II dispersion surfaces in heavily distorted crystals are discussed, and in the discussion the resonance shift functions are introduced. These formulations can lead to a complete understanding of the extinction phenomena. (author)

  6. Spectral Distortion in Lossy Compression of Hyperspectral Data

    Directory of Open Access Journals (Sweden)

    Bruno Aiazzi

    2012-01-01

    Full Text Available Distortion allocation varying with wavelength in lossy compression of hyperspectral imagery is investigated, with the aim of minimizing the spectral distortion between original and decompressed data. The absolute angular error, or spectral angle mapper (SAM, is used to quantify spectral distortion, while radiometric distortions are measured by maximum absolute deviation (MAD for near-lossless methods, for example, differential pulse code modulation (DPCM, or mean-squared error (MSE for lossy methods, for example, spectral decorrelation followed by JPEG 2000. Two strategies of interband distortion allocation are compared: given a target average bit rate, distortion may be set to be constant with wavelength. Otherwise, it may be allocated proportionally to the noise level of each band, according to the virtually lossless protocol. Comparisons with the uncompressed originals show that the average SAM of radiance spectra is minimized by constant distortion allocation to radiance data. However, variable distortion allocation according to the virtually lossless protocol yields significantly lower SAM in case of reflectance spectra obtained from compressed radiance data, if compared with the constant distortion allocation at the same compression ratio.

  7. Logarithmic corrections to gravitational entropy and the null energy condition

    Directory of Open Access Journals (Sweden)

    Maulik Parikh

    2016-10-01

    Full Text Available Using a relation between the thermodynamics of local horizons and the null energy condition, we consider the effects of quantum corrections to the gravitational entropy. In particular, we find that the geometric form of the null energy condition is not affected by the inclusion of logarithmic corrections to the Bekenstein–Hawking entropy.

  8. Geometric Energy Derivatives at the Complete Basis Set Limit: Application to the Equilibrium Structure and Molecular Force Field of Formaldehyde.

    Science.gov (United States)

    Morgan, W James; Matthews, Devin A; Ringholm, Magnus; Agarwal, Jay; Gong, Justin Z; Ruud, Kenneth; Allen, Wesley D; Stanton, John F; Schaefer, Henry F

    2018-03-13

    Geometric energy derivatives which rely on core-corrected focal-point energies extrapolated to the complete basis set (CBS) limit of coupled cluster theory with iterative and noniterative quadruple excitations, CCSDTQ and CCSDT(Q), are used as elements of molecular gradients and, in the case of CCSDT(Q), expansion coefficients of an anharmonic force field. These gradients are used to determine the CCSDTQ/CBS and CCSDT(Q)/CBS equilibrium structure of the S 0 ground state of H 2 CO where excellent agreement is observed with previous work and experimentally derived results. A fourth-order expansion about this CCSDT(Q)/CBS reference geometry using the same level of theory produces an exceptional level of agreement to spectroscopically observed vibrational band origins with a MAE of 0.57 cm -1 . Second-order vibrational perturbation theory (VPT2) and variational discrete variable representation (DVR) results are contrasted and discussed. Vibration-rotation, anharmonicity, and centrifugal distortion constants from the VPT2 analysis are reported and compared to previous work. Additionally, an initial application of a sum-over-states fourth-order vibrational perturbation theory (VPT4) formalism is employed herein, utilizing quintic and sextic derivatives obtained with a recursive algorithmic approach for response theory.

  9. Distortions in Judged Spatial Relations.

    Science.gov (United States)

    Stevens, Albert

    1978-01-01

    Distortions in judgments of relative geographical relations were observed, particularly when the locations were in different geographical or political units. Subjects distorted the judged relation to conform with the relation of the superordinate political unit. A model for the hierachical storage of spatial information is presented. (Author/RD)

  10. Pile-up correction by Genetic Algorithm and Artificial Neural Network

    Science.gov (United States)

    Kafaee, M.; Saramad, S.

    2009-08-01

    Pile-up distortion is a common problem for high counting rates radiation spectroscopy in many fields such as industrial, nuclear and medical applications. It is possible to reduce pulse pile-up using hardware-based pile-up rejections. However, this phenomenon may not be eliminated completely by this approach and the spectrum distortion caused by pile-up rejection can be increased as well. In addition, inaccurate correction or rejection of pile-up artifacts in applications such as energy dispersive X-ray (EDX) spectrometers can lead to losses of counts, will give poor quantitative results and even false element identification. Therefore, it is highly desirable to use software-based models to predict and correct any recognized pile-up signals in data acquisition systems. The present paper describes two new intelligent approaches for pile-up correction; the Genetic Algorithm (GA) and Artificial Neural Networks (ANNs). The validation and testing results of these new methods have been compared, which shows excellent agreement with the measured data with 60Co source and NaI detector. The Monte Carlo simulation of these new intelligent algorithms also shows their advantages over hardware-based pulse pile-up rejection methods.

  11. JET ENGINE INLET DISTORTION SCREEN AND DESCRIPTOR EVALUATION

    Directory of Open Access Journals (Sweden)

    Jiří Pečinka

    2017-02-01

    Full Text Available Total pressure distortion is one of the three basic flow distortions (total pressure, total temperature and swirl distortion that might appear at the inlet of a gas turbine engine (GTE during operation. Different numerical parameters are used for assessing the total pressure distortion intensity and extent. These summary descriptors are based on the distribution of total pressure in the aerodynamic interface plane. There are two descriptors largely spread around the world, however, three or four others are still in use and can be found in current references. The staff at the University of Defence decided to compare the most common descriptors using basic flow distortion patterns in order to select the most appropriate descriptor for future department research. The most common descriptors were identified based on their prevalence in widely accessible publications. The construction and use of these descriptors are reviewed in the paper. Subsequently, they are applied to radial, angular, and combined distortion patterns of different intensities and with varied mass flow rates. The tests were performed on a specially designed test bench using an electrically driven standalone industrial centrifugal compressor, sucking air through the inlet of a TJ100 small turbojet engine. Distortion screens were placed into the inlet channel to create the desired total pressure distortions. Of the three basic distortions, only the total pressure distortion descriptors were evaluated. However, both total and static pressures were collected using a multi probe rotational measurement system.

  12. Geometrical considerations in analyzing isotropic or anisotropic surface reflections.

    Science.gov (United States)

    Simonot, Lionel; Obein, Gael

    2007-05-10

    The bidirectional reflectance distribution function (BRDF) represents the evolution of the reflectance with the directions of incidence and observation. Today BRDF measurements are increasingly applied and have become important to the study of the appearance of surfaces. The representation and the analysis of BRDF data are discussed, and the distortions caused by the traditional representation of the BRDF in a Fourier plane are pointed out and illustrated for two theoretical cases: an isotropic surface and a brushed surface. These considerations will help characterize either the specular peak width of an isotropic rough surface or the main directions of the light scattered by an anisotropic rough surface without misinterpretations. Finally, what is believed to be a new space is suggested for the representation of the BRDF, which avoids the geometrical deformations and in numerous cases is more convenient for BRDF analysis.

  13. Artefacts in geometric phase analysis of compound materials.

    Science.gov (United States)

    Peters, Jonathan J P; Beanland, Richard; Alexe, Marin; Cockburn, John W; Revin, Dmitry G; Zhang, Shiyong Y; Sanchez, Ana M

    2015-10-01

    The geometric phase analysis (GPA) algorithm is known as a robust and straightforward technique that can be used to measure lattice strains in high resolution transmission electron microscope (TEM) images. It is also attractive for analysis of aberration-corrected scanning TEM (ac-STEM) images that resolve every atom column, since it uses Fourier transforms and does not require real-space peak detection and assignment to appropriate sublattices. Here it is demonstrated that, in ac-STEM images of compound materials with compositionally distinct atom columns, an additional geometric phase is present in the Fourier transform. If the structure changes from one area to another in the image (e.g. across an interface), the change in this additional phase will appear as a strain in conventional GPA, even if there is no lattice strain. Strategies to avoid this pitfall are outlined. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Distortional Modes of Thin-Walled Beams

    DEFF Research Database (Denmark)

    Jönsson, Jeppe; Andreassen, Michael Joachim

    2009-01-01

    The classic thin-walled beam theory for open and closed cross-sections can be generalized by including distortional displacement modes. The introduction of additional displacement modes leads to coupled differential equations, which seems to have prohibited the use of exact shape functions...... in the modelling of coupled torsion and distortion. However, if the distortional displacement modes are chosen as those which decouple the differential equations as in non proportionally damped modal dynamic analysis then it may be possible to use exact shape functions and perform analysis on a reduced problem....... In the recently developed generalized beam theory (GBT) the natural distortional displacement modes are determined on the basis of a quadratic eigenvalue problem. However, as in linear modal dynamic analysis of proportionally damped structures this problem has been solved approximately using linear eigenvalue...

  15. Geometrical modelling of scanning probe microscopes and characterization of errors

    International Nuclear Information System (INIS)

    Marinello, F; Savio, E; Bariani, P; Carmignato, S

    2009-01-01

    Scanning probe microscopes (SPMs) allow quantitative evaluation of surface topography with ultra-high resolution, as a result of accurate actuation combined with the sharpness of tips. SPMs measure sequentially, by scanning surfaces in a raster fashion: topography maps commonly consist of data sets ideally reported in an orthonormal rectilinear Cartesian coordinate system. However, due to scanning errors and measurement distortions, the measurement process is far from the ideal Cartesian condition. The paper addresses geometrical modelling of the scanning system dynamics, presenting a mathematical model which describes the surface metric x-, y- and z- coordinates as a function of the measured x'-, y'- and z'-coordinates respectively. The complete mathematical model provides a relevant contribution to characterization and calibration, and ultimately to traceability, of SPMs, when applied for quantitative characterization

  16. Removing Distortion of Periapical Radiographs in Dental Digital Radiography Using Embedded Markers in an External frame.

    Science.gov (United States)

    Kafieh, Rahele; Shahamoradi, Mahdi; Hekmatian, Ehsan; Foroohandeh, Mehrdad; Emamidoost, Mostafa

    2012-10-01

    To carry out in vivo and in vitro comparative pilot study to evaluate the preciseness of a newly proposed digital dental radiography setup. This setup was based on markers placed on an external frame to eliminate the measurement errors due to incorrect geometry in relative positioning of cone, teeth and the sensor. Five patients with previous panoramic images were selected to undergo the proposed periapical digital imaging for in vivo phase. For in vitro phase, 40 extracted teeth were replanted in dry mandibular sockets and periapical digital images were prepared. The standard reference for real scales of the teeth were obtained through extracted teeth measurements for in vitro application and were calculated through panoramic imaging for in vivo phases. The proposed image processing thechnique was applied on periapical digital images to distinguish the incorrect geometry. The recognized error was inversely applied on the image and the modified images were compared to the correct values. The measurement findings after the distortion removal were compared to our gold standards (results of panoramic imaging or measurements from extracted teeth) and showed the accuracy of 96.45% through in vivo examinations and 96.0% through in vitro tests. The proposed distortion removal method is perfectly able to identify the possible inaccurate geometry during image acquisition and is capable of applying the inverse transform to the distorted radiograph to obtain the correctly modified image. This can be really helpful in applications like root canal therapy, implant surgical procedures and digital subtraction radiography, which are essentially dependent on precise measurements.

  17. 3-D Imaging Using Row–Column-Addressed Arrays With Integrated Apodization. Part I: Apodization Design and Line Element Beamforming

    DEFF Research Database (Denmark)

    Rasmussen, Morten Fischer; Christiansen, Thomas Lehrmann; Thomsen, Erik Vilain

    2015-01-01

    -integrated apodization increased the apparent diameter of the vessel from 2.0 mm to 2.4 mm, corresponding to an increase from 67% to 80% of the true vessel diameter. The line element beamforming approach is shown to be essential for achieving correct time-of-flight calculations, and hence avoid geometrical distortions...

  18. Brane cosmology with curvature corrections

    International Nuclear Information System (INIS)

    Kofinas, Georgios; Maartens, Roy; Papantonopoulos, Eleftherios

    2003-01-01

    We study the cosmology of the Randall-Sundrum brane-world where the Einstein-Hilbert action is modified by curvature correction terms: a four-dimensional scalar curvature from induced gravity on the brane, and a five-dimensional Gauss-Bonnet curvature term. The combined effect of these curvature corrections to the action removes the infinite-density big bang singularity, although the curvature can still diverge for some parameter values. A radiation brane undergoes accelerated expansion near the minimal scale factor, for a range of parameters. This acceleration is driven by the geometric effects, without an inflation field or negative pressures. At late times, conventional cosmology is recovered. (author)

  19. Photoacoustic signal and noise analysis for Si thin plate: signal correction in frequency domain.

    Science.gov (United States)

    Markushev, D D; Rabasović, M D; Todorović, D M; Galović, S; Bialkowski, S E

    2015-03-01

    Methods for photoacoustic signal measurement, rectification, and analysis for 85 μm thin Si samples in the 20-20 000 Hz modulation frequency range are presented. Methods for frequency-dependent amplitude and phase signal rectification in the presence of coherent and incoherent noise as well as distortion due to microphone characteristics are presented. Signal correction is accomplished using inverse system response functions deduced by comparing real to ideal signals for a sample with well-known bulk parameters and dimensions. The system response is a piece-wise construction, each component being due to a particular effect of the measurement system. Heat transfer and elastic effects are modeled using standard Rosencweig-Gersho and elastic-bending theories. Thermal diffusion, thermoelastic, and plasmaelastic signal components are calculated and compared to measurements. The differences between theory and experiment are used to detect and correct signal distortion and to determine detector and sound-card characteristics. Corrected signal analysis is found to faithfully reflect known sample parameters.

  20. Detection of chromatic and luminance distortions in natural scenes.

    Science.gov (United States)

    Jennings, Ben J; Wang, Karen; Menzies, Samantha; Kingdom, Frederick A A

    2015-09-01

    A number of studies have measured visual thresholds for detecting spatial distortions applied to images of natural scenes. In one study, Bex [J. Vis.10(2), 1 (2010)10.1167/10.2.231534-7362] measured sensitivity to sinusoidal spatial modulations of image scale. Here, we measure sensitivity to sinusoidal scale distortions applied to the chromatic, luminance, or both layers of natural scene images. We first established that sensitivity does not depend on whether the undistorted comparison image was of the same or of a different scene. Next, we found that, when the luminance but not chromatic layer was distorted, performance was the same regardless of whether the chromatic layer was present, absent, or phase-scrambled; in other words, the chromatic layer, in whatever form, did not affect sensitivity to the luminance layer distortion. However, when the chromatic layer was distorted, sensitivity was higher when the luminance layer was intact compared to when absent or phase-scrambled. These detection threshold results complement the appearance of periodic distortions of the image scale: when the luminance layer is distorted visibly, the scene appears distorted, but when the chromatic layer is distorted visibly, there is little apparent scene distortion. We conclude that (a) observers have a built-in sense of how a normal image of a natural scene should appear, and (b) the detection of distortion in, as well as the apparent distortion of, natural scene images is mediated predominantly by the luminance layer and not chromatic layer.

  1. Prediction of transmission distortion for wireless video communication: analysis.

    Science.gov (United States)

    Chen, Zhifeng; Wu, Dapeng

    2012-03-01

    Transmitting video over wireless is a challenging problem since video may be seriously distorted due to packet errors caused by wireless channels. The capability of predicting transmission distortion (i.e., video distortion caused by packet errors) can assist in designing video encoding and transmission schemes that achieve maximum video quality or minimum end-to-end video distortion. This paper is aimed at deriving formulas for predicting transmission distortion. The contribution of this paper is twofold. First, we identify the governing law that describes how the transmission distortion process evolves over time and analytically derive the transmission distortion formula as a closed-form function of video frame statistics, channel error statistics, and system parameters. Second, we identify, for the first time, two important properties of transmission distortion. The first property is that the clipping noise, which is produced by nonlinear clipping, causes decay of propagated error. The second property is that the correlation between motion-vector concealment error and propagated error is negative and has dominant impact on transmission distortion, compared with other correlations. Due to these two properties and elegant error/distortion decomposition, our formula provides not only more accurate prediction but also lower complexity than the existing methods.

  2. Ultrasonographic Findings of Mammographic Architectural Distortion

    International Nuclear Information System (INIS)

    Ma, Jeong Hyun; Kang, Bong Joo; Cha, Eun Suk; Hwangbo, Seol; Kim, Hyeon Sook; Park, Chang Suk; Kim, Sung Hun; Choi, Jae Jeong; Chung, Yong An

    2008-01-01

    To review the sonographic findings of various diseases showing architectural distortion depicted under mammography. We collected and reviewed architectural distortions observed under mammography at our health institution between 1 March 2004, and 28 February 2007. We collected 23 cases of sonographically-detected mammographic architectural distortions that confirmed lesions after surgical resection. The sonographic findings of mammographic architectural distortion were analyzed by use of the BI-RADS lexicon for shape, margin, lesion boundary, echo pattern, posterior acoustic feature and orientation. There were variable diseases that showed architectural distortion depicted under mammography. Fibrocystic disease was the most common presentation (n = 6), followed by adenosis (n = 2), stromal fibrosis (n = 2), radial scar (n = 3), usual ductal hyperplasia (n = 1), atypical ductal hyperplasia (n = 1) and mild fibrosis with microcalcification (n = 1). Malignant lesions such as ductal carcinoma in situ (DCIS) (n = 2), lobular carcinoma in situ (LCIS) (n = 2), invasive ductal carcinoma (n = 2) and invasive lobular carcinoma (n = 1) were observed. As observed by sonography, shape was divided as irregular (n = 22) and round (n = 1). Margin was divided as circumscribed (n = 1), indistinct (n = 7), angular (n = 1), microlobulated (n = 1) and sipculated (n = 13). Lesion boundary was divided as abrupt interface (n = 11) and echogenic halo (n = 12). Echo pattern was divided as hypoechoic (n = 20), anechoic (n = 1), hyperechoic (n = 1) and isoechoic (n = 1). Posterior acoustic feature was divided as posterior acoustic feature (n = 7), posterior acoustic shadow (n = 15) and complex posterior acoustic feature (n = 1). Orientation was divided as parallel (n = 12) and not parallel (n = 11). There were no differential sonographic findings between benign and malignant lesions. This study presented various sonographic findings of mammographic architectural distortion and that it is

  3. Three dimensional topography correction applied to magnetotelluric data from Sikkim Himalayas

    Science.gov (United States)

    Kumar, Sushil; Patro, Prasanta K.; Chaudhary, B. S.

    2018-06-01

    Magnetotelluric (MT) method is one of the powerful tools to investigate the deep crustal image of mountainous regions such as Himalayas. Topographic variations due to irregular surface terrain distort the resistivity curves and hence may not give accurate interpretation of magnetotelluric data. The two-dimensional (2-D) topographic effects in Transverse Magnetic (TM) mode is only galvanic whereas inductive in Transverse Electric (TE) mode, thus TM mode responses is much more important than TE mode responses in 2-D. In three-dimensional (3-D), the topography effect is both galvanic and inductive in each element of impedance tensor and hence the interpretation is complicated. In the present work, we investigate the effects of three-dimensional (3-D) topography for a hill model. This paper presents the impedance tensor correction algorithm to reduce the topographic effects in MT data. The distortion caused by surface topography effectively decreases by using homogeneous background resistivity in impedance correction method. In this study, we analyze the response of ramp, distance from topographic edges, conductive and resistive dykes. The new correction method is applied to the real data from Sikkim Himalayas, which brought out the true nature of the basement in this region.

  4. Components of segregation distortion in Drosophila melanogaster

    International Nuclear Information System (INIS)

    Ganetzky, B.

    1977-01-01

    The segregation distorter (SD) complex is a naturally occurring meiotic drive system with the property that males heterozygous for an SD-bearing chromosome 2 and an SD+-bearing homolog transmit the SD-bearing chromosome almost exclusively. This distorted segregation is the consequence of an induced dysfunction of those sperm that receive the SD+ homolog. From previous studies, two loci have been implicated in this phenomenon: the Sd locus which is required to produce distortion, and the Responder (Rsp) locus that is the site at which Sd acts. There are two allelic alternatives of Rsp-sensitive (Rsp/sup sens/) and insensitive (Rsp/sup ins/); a chromosome carrying Rsp/sup ins/ is not distorted by SD. In the present study, the function and location of each of these elements was examined by a genetic and cytological characterization of x-ray-induced mutations at each locus. The results indicate the following: the Rsp locus is located in the proximal heterochromatin of 2R; a deletion for the Rsp locus renders a chromosome insensitive to distortion; the Sd locus is located to the left of pr (2-54.5), in the region from 37D2-D7 to 38A6-B2 of the salivary chromosome map; an SD chromosome deleted for Sd loses its ability to distort; there is another important component of the SD system, E(SD), in or near the proximal heterochromatin of 2L, that behaves as a strong enhancer of distortion. The results of these studies allow a reinterpretation of results from earlier analyses of the SD system and serve to limit the possible mechanisms to account for segregation distortion

  5. A geometrical correction for the inter- and intra-molecular basis set superposition error in Hartree-Fock and density functional theory calculations for large systems

    Science.gov (United States)

    Kruse, Holger; Grimme, Stefan

    2012-04-01

    A semi-empirical counterpoise-type correction for basis set superposition error (BSSE) in molecular systems is presented. An atom pair-wise potential corrects for the inter- and intra-molecular BSSE in supermolecular Hartree-Fock (HF) or density functional theory (DFT) calculations. This geometrical counterpoise (gCP) denoted scheme depends only on the molecular geometry, i.e., no input from the electronic wave-function is required and hence is applicable to molecules with ten thousands of atoms. The four necessary parameters have been determined by a fit to standard Boys and Bernadi counterpoise corrections for Hobza's S66×8 set of non-covalently bound complexes (528 data points). The method's target are small basis sets (e.g., minimal, split-valence, 6-31G*), but reliable results are also obtained for larger triple-ζ sets. The intermolecular BSSE is calculated by gCP within a typical error of 10%-30% that proves sufficient in many practical applications. The approach is suggested as a quantitative correction in production work and can also be routinely applied to estimate the magnitude of the BSSE beforehand. The applicability for biomolecules as the primary target is tested for the crambin protein, where gCP removes intramolecular BSSE effectively and yields conformational energies comparable to def2-TZVP basis results. Good mutual agreement is also found with Jensen's ACP(4) scheme, estimating the intramolecular BSSE in the phenylalanine-glycine-phenylalanine tripeptide, for which also a relaxed rotational energy profile is presented. A variety of minimal and double-ζ basis sets combined with gCP and the dispersion corrections DFT-D3 and DFT-NL are successfully benchmarked on the S22 and S66 sets of non-covalent interactions. Outstanding performance with a mean absolute deviation (MAD) of 0.51 kcal/mol (0.38 kcal/mol after D3-refit) is obtained at the gCP-corrected HF-D3/(minimal basis) level for the S66 benchmark. The gCP-corrected B3LYP-D3/6-31G* model

  6. A geometrical correction for the inter- and intra-molecular basis set superposition error in Hartree-Fock and density functional theory calculations for large systems.

    Science.gov (United States)

    Kruse, Holger; Grimme, Stefan

    2012-04-21

    A semi-empirical counterpoise-type correction for basis set superposition error (BSSE) in molecular systems is presented. An atom pair-wise potential corrects for the inter- and intra-molecular BSSE in supermolecular Hartree-Fock (HF) or density functional theory (DFT) calculations. This geometrical counterpoise (gCP) denoted scheme depends only on the molecular geometry, i.e., no input from the electronic wave-function is required and hence is applicable to molecules with ten thousands of atoms. The four necessary parameters have been determined by a fit to standard Boys and Bernadi counterpoise corrections for Hobza's S66×8 set of non-covalently bound complexes (528 data points). The method's target are small basis sets (e.g., minimal, split-valence, 6-31G*), but reliable results are also obtained for larger triple-ζ sets. The intermolecular BSSE is calculated by gCP within a typical error of 10%-30% that proves sufficient in many practical applications. The approach is suggested as a quantitative correction in production work and can also be routinely applied to estimate the magnitude of the BSSE beforehand. The applicability for biomolecules as the primary target is tested for the crambin protein, where gCP removes intramolecular BSSE effectively and yields conformational energies comparable to def2-TZVP basis results. Good mutual agreement is also found with Jensen's ACP(4) scheme, estimating the intramolecular BSSE in the phenylalanine-glycine-phenylalanine tripeptide, for which also a relaxed rotational energy profile is presented. A variety of minimal and double-ζ basis sets combined with gCP and the dispersion corrections DFT-D3 and DFT-NL are successfully benchmarked on the S22 and S66 sets of non-covalent interactions. Outstanding performance with a mean absolute deviation (MAD) of 0.51 kcal/mol (0.38 kcal/mol after D3-refit) is obtained at the gCP-corrected HF-D3/(minimal basis) level for the S66 benchmark. The gCP-corrected B3LYP-D3/6-31G* model

  7. Electron capture by alpha particles from helium atoms in a Coulomb-Born distorted-wave approximation

    International Nuclear Information System (INIS)

    Ghanbari-Adivi, E; Ghavaminia, H

    2012-01-01

    A three-body Coulomb-Born continuum distorted-wave approximation is applied to calculate the differential and total cross sections for single-electron exchange in the collision of fast alpha particles with helium atoms in their ground states. The applied first-order distorted wave theory satisfies correct Coulomb boundary conditions. Both post and prior forms of the transition amplitude are calculated. The nuclear-screening effect of the passive electron on the differential and total cross sections is investigated. The results are compared with those of other theories and with the available experimental data. For differential cross sections, the comparisons show a reasonable agreement with empirical measurements at higher impact energies. The agreement between experimental data and the present calculations for total cross sections with the average of the post and prior forms of the transition amplitude is reasonable at all the specified energies.

  8. Sonographic ally Detected Architectural Distortion: Clinical Significance

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Shin Kee; Seo, Bo Kyoung; Yi, Ann; Cha, Sang Hoon; Kim, Baek Hyun; Cho, Kyu Ran; Kim, Young Sik; Son, Gil Soo; Kim, Young Soo; Kim, Hee Young [Korea University Ansan Hospital, Ansan (Korea, Republic of)

    2008-12-15

    Architectural distortion is a suspicious abnormality for the diagnosis of breast cancer. The aim of this study was to investigate the clinical significance of sonographic ally detected architectural distortion. From January 2006 to June 2008, 20 patients were identified who had sonographic ally detected architectural distortions without a history of trauma or surgery and abnormal mammographic findings related to an architectural distortion. All of the lesions were pathologically verified. We evaluated the clinical and pathological findings and then assessed the clinical significance of the sonographic ally detected architectural distortions. Based on the clinical findings, one (5%) of the 20 patients had a palpable lump and the remaining 19 patients had no symptoms. No patient had a family history of breast cancer. Based on the pathological findings, three (15%) patients had malignancies. The malignant lesions included invasive ductal carcinomas (n = 2) and ductal carcinoma in situ (n = 1). Four (20%) patients had high-risk lesions: atypical ductal hyperplasia (n = 3) and lobular carcinoma in situ (n = 1). The remaining 13 (65%) patients had benign lesions, however, seven (35%) out of 13 patients had mild-risk lesions (three intraductal papillomas, three moderate or florid epithelial hyperplasia and one sclerosing adenosis). Of the sonographic ally detected architectural distortions, 35% were breast cancers or high-risk lesions and 35% were mild-risk lesions. Thus, a biopsy might be needed for an architectural distortion without an associated mass as depicted on breast ultrasound, even though the mammographic findings are normal

  9. Sonographic ally Detected Architectural Distortion: Clinical Significance

    International Nuclear Information System (INIS)

    Kim, Shin Kee; Seo, Bo Kyoung; Yi, Ann; Cha, Sang Hoon; Kim, Baek Hyun; Cho, Kyu Ran; Kim, Young Sik; Son, Gil Soo; Kim, Young Soo; Kim, Hee Young

    2008-01-01

    Architectural distortion is a suspicious abnormality for the diagnosis of breast cancer. The aim of this study was to investigate the clinical significance of sonographic ally detected architectural distortion. From January 2006 to June 2008, 20 patients were identified who had sonographic ally detected architectural distortions without a history of trauma or surgery and abnormal mammographic findings related to an architectural distortion. All of the lesions were pathologically verified. We evaluated the clinical and pathological findings and then assessed the clinical significance of the sonographic ally detected architectural distortions. Based on the clinical findings, one (5%) of the 20 patients had a palpable lump and the remaining 19 patients had no symptoms. No patient had a family history of breast cancer. Based on the pathological findings, three (15%) patients had malignancies. The malignant lesions included invasive ductal carcinomas (n = 2) and ductal carcinoma in situ (n = 1). Four (20%) patients had high-risk lesions: atypical ductal hyperplasia (n = 3) and lobular carcinoma in situ (n = 1). The remaining 13 (65%) patients had benign lesions, however, seven (35%) out of 13 patients had mild-risk lesions (three intraductal papillomas, three moderate or florid epithelial hyperplasia and one sclerosing adenosis). Of the sonographic ally detected architectural distortions, 35% were breast cancers or high-risk lesions and 35% were mild-risk lesions. Thus, a biopsy might be needed for an architectural distortion without an associated mass as depicted on breast ultrasound, even though the mammographic findings are normal

  10. Can journalistic "false balance" distort public perception of consensus in expert opinion?

    Science.gov (United States)

    Koehler, Derek J

    2016-03-01

    Media critics have expressed concern that journalistic "false balance" can distort the public's perceptions of what ought to be noncontroversial subjects (e.g., climate change). I report several experiments testing the influence of presenting conflicting comments from 2 experts who disagree on an issue (balance condition) in addition to a complete count of the number of experts on a panel who favor either side. Compared with a control condition, who received only the complete count, participants in the balance condition gave ratings of the perceived agreement among the experts that did not discriminate as clearly between issues with and without strong expert consensus. Participants in the balance condition also perceived less agreement among the experts in general, and were less likely to think that there was enough agreement among experts on the high-consensus issues to guide government policy. Evidently, "false balance" can distort perceptions of expert opinion even when participants would seem to have all the information needed to correct for its influence. (c) 2016 APA, all rights reserved).

  11. Visualizing the Geometric Series.

    Science.gov (United States)

    Bennett, Albert B., Jr.

    1989-01-01

    Mathematical proofs often leave students unconvinced or without understanding of what has been proved, because they provide no visual-geometric representation. Presented are geometric models for the finite geometric series when r is a whole number, and the infinite geometric series when r is the reciprocal of a whole number. (MNS)

  12. Application of Riesz transforms to the isotropic AM-PM decomposition of geometrical-optical illusion images.

    Science.gov (United States)

    Sierra-Vázquez, Vicente; Serrano-Pedraza, Ignacio

    2010-04-01

    The existence of a special second-order mechanism in the human visual system, able to demodulate the envelope of visual stimuli, suggests that spatial information contained in the image envelope may be perceptually relevant. The Riesz transform, a natural isotropic extension of the Hilbert transform to multidimensional signals, was used here to demodulate band-pass filtered images of well-known visual illusions of length, size, direction, and shape. We show that the local amplitude of the monogenic signal or envelope of each illusion image conveys second-order information related to image holistic spatial structure, whereas the local phase component conveys information about the spatial features. Further low-pass filtering of the illusion image envelopes creates physical distortions that correspond to the subjective distortions perceived in the illusory images. Therefore the envelope seems to be the image component that physically carries the spatial information about these illusions. This result contradicts the popular belief that the relevant spatial information to perceive geometrical-optical illusions is conveyed only by the lower spatial frequencies present in their Fourier spectrum.

  13. Geometric analysis

    CERN Document Server

    Bray, Hubert L; Mazzeo, Rafe; Sesum, Natasa

    2015-01-01

    This volume includes expanded versions of the lectures delivered in the Graduate Minicourse portion of the 2013 Park City Mathematics Institute session on Geometric Analysis. The papers give excellent high-level introductions, suitable for graduate students wishing to enter the field and experienced researchers alike, to a range of the most important areas of geometric analysis. These include: the general issue of geometric evolution, with more detailed lectures on Ricci flow and Kähler-Ricci flow, new progress on the analytic aspects of the Willmore equation as well as an introduction to the recent proof of the Willmore conjecture and new directions in min-max theory for geometric variational problems, the current state of the art regarding minimal surfaces in R^3, the role of critical metrics in Riemannian geometry, and the modern perspective on the study of eigenfunctions and eigenvalues for Laplace-Beltrami operators.

  14. Non-geometric five-branes in heterotic supergravity

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, Shin; Yata, Masaya [Department of Physics, Kitasato University,Sagamihara 252-0373 (Japan); Department of Physics, National University of Singapore,2, Science Drive 3, Singapore 117542 (Singapore)

    2016-11-10

    We study T-duality chains of five-branes in heterotic supergravity where the first order α{sup ′}-corrections are present. By performing the α{sup ′}-corrected T-duality transformations of the heterotic NS5-brane solutions, we obtain the KK5-brane and the exotic 5{sub 2}{sup 2}-brane solutions associated with the symmetric, the neutral and the gauge NS5-branes. We find that the Yang-Mills gauge field in these solutions satisfies the self-duality condition in the three- and two-dimensional transverse spaces to the brane world-volumes. The O(2,2) monodromy structures of the 5{sub 2}{sup 2}-brane solutions are investigated by the α{sup ′}-corrected generalized metric. Our analysis shows that the symmetric 5{sub 2}{sup 2}-brane solution, which satisfies the standard embedding condition, is a T-fold and it exhibits the non-geometric nature. We also find that the neutral 5{sub 2}{sup 2}-brane solution is a T-fold at least at O(α{sup ′}). On the other hand, the gauge 5{sub 2}{sup 2}-brane solution is not a T-fold but show unusual structures of space-time.

  15. On bivariate geometric distribution

    Directory of Open Access Journals (Sweden)

    K. Jayakumar

    2013-05-01

    Full Text Available Characterizations of bivariate geometric distribution using univariate and bivariate geometric compounding are obtained. Autoregressive models with marginals as bivariate geometric distribution are developed. Various bivariate geometric distributions analogous to important bivariate exponential distributions like, Marshall-Olkin’s bivariate exponential, Downton’s bivariate exponential and Hawkes’ bivariate exponential are presented.

  16. FSD: Frequency Space Differential measurement of CMB spectral distortions

    Science.gov (United States)

    Mukherjee, Suvodip; Silk, Joseph; Wandelt, Benjamin D.

    2018-04-01

    Although the Cosmic Microwave Background agrees with a perfect blackbody spectrum within the current experimental limits, it is expected to exhibit certain spectral distortions with known spectral properties. We propose a new method, Frequency Space Differential (FSD) to measure the spectral distortions in the CMB spectrum by using the inter-frequency differences of the brightness temperature. The difference between the observed CMB temperature at different frequencies must agree with the frequency derivative of the blackbody spectrum, in the absence of any distortion. However, in the presence of spectral distortions, the measured inter-frequency differences would also exhibit deviations from blackbody which can be modeled for known sources of spectral distortions like y & μ. Our technique uses FSD information for the CMB blackbody, y, μ or any other sources of spectral distortions to model the observed signal. Successful application of this method in future CMB missions can provide an alternative method to extract spectral distortion signals and can potentially make it feasible to measure spectral distortions without an internal blackbody calibrator.

  17. A new method to make gamma-ray self-absorption correction

    International Nuclear Information System (INIS)

    Tian Dongfeng; Xie Dong; Ho Yukun; Yang Fujia

    2001-01-01

    This paper is devoted to discuss a new method to directly extract the information of the geometric self-absorption correction through the measurement of characteristic γ radiation emitted spontaneously from nuclear fissile material. The numerical simulation tests show that this method can extract the purely original information needed for nondestructive assay method by the γ-ray spectra to be measured, even though the geometric shape of the sample and materials between sample and detector are not known in advance. (author)

  18. Geometrically exact nonlinear analysis of pre-twisted composite rotor blades

    Directory of Open Access Journals (Sweden)

    Li'na SHANG

    2018-02-01

    Full Text Available Modeling of pre-twisted composite rotor blades is very complicated not only because of the geometric non-linearity, but also because of the cross-sectional warping and the transverse shear deformation caused by the anisotropic material properties. In this paper, the geometrically exact nonlinear modeling of a generalized Timoshenko beam with arbitrary cross-sectional shape, generally anisotropic material behavior and large deflections has been presented based on Hodges’ method. The concept of decomposition of rotation tensor was used to express the strain in the beam. The variational asymptotic method was used to determine the arbitrary warping of the beam cross section. The generalized Timoshenko strain energy was derived from the equilibrium equations and the second-order asymptotically correct strain energy. The geometrically exact nonlinear equations of motion were established by Hamilton’s principle. The established modeling was used for the static and dynamic analysis of pre-twisted composite rotor blades, and the analytical results were validated based on experimental data. The influences of the transverse shear deformation on the pre-twisted composite rotor blade were investigated. The results indicate that the influences of the transverse shear deformation on the static deformation and the natural frequencies of the pre-twisted composite rotor blade are related to the length to chord ratio of the blade. Keywords: Geometrically exact, Nonlinear, Pre-twisted composite blade, Transverse shear deformation, Variational asymptotic, Warping

  19. Automatic low-order aberration correction based on geometrical optics for slab lasers.

    Science.gov (United States)

    Yu, Xin; Dong, Lizhi; Lai, Boheng; Yang, Ping; Liu, Yong; Kong, Qingfeng; Yang, Kangjian; Tang, Guomao; Xu, Bing

    2017-02-20

    In this paper, we present a method based on geometry optics to simultaneously correct low-order aberrations and reshape the beams of slab lasers. A coaxial optical system with three lenses is adapted. The positions of the three lenses are directly calculated based on the beam parameters detected by wavefront sensors. The initial sizes of the input beams are 1.8  mm×11  mm, and peak-to-valley (PV) values of the wavefront range up to several tens of microns. After automatic correction, the dimensions may reach nearly 22  mm×22  mm as expected, and PV values of the wavefront are less than 2 μm. The effectiveness and precision of this method are verified with experiments.

  20. Navigability of Random Geometric Graphs in the Universe and Other Spacetimes.

    Science.gov (United States)

    Cunningham, William; Zuev, Konstantin; Krioukov, Dmitri

    2017-08-18

    Random geometric graphs in hyperbolic spaces explain many common structural and dynamical properties of real networks, yet they fail to predict the correct values of the exponents of power-law degree distributions observed in real networks. In that respect, random geometric graphs in asymptotically de Sitter spacetimes, such as the Lorentzian spacetime of our accelerating universe, are more attractive as their predictions are more consistent with observations in real networks. Yet another important property of hyperbolic graphs is their navigability, and it remains unclear if de Sitter graphs are as navigable as hyperbolic ones. Here we study the navigability of random geometric graphs in three Lorentzian manifolds corresponding to universes filled only with dark energy (de Sitter spacetime), only with matter, and with a mixture of dark energy and matter. We find these graphs are navigable only in the manifolds with dark energy. This result implies that, in terms of navigability, random geometric graphs in asymptotically de Sitter spacetimes are as good as random hyperbolic graphs. It also establishes a connection between the presence of dark energy and navigability of the discretized causal structure of spacetime, which provides a basis for a different approach to the dark energy problem in cosmology.

  1. Verification for the disagreement between effective point and geometrical center of thimble ionization chamber

    International Nuclear Information System (INIS)

    Shimomura, K.; Tabushi, K.

    2005-01-01

    In radiotherapy, it is certainly necessary to grasp the quantity and the distribution of the radiation administered to the human body. To measure these correctly, the standard measurement method of the absorbed dose of water is recommended by AAPM, IAEA, and JSPM. The standard method also recommends that absolute measurements should be performed using the thimble ionization chamber (TIC). The absorbed dose of water measured by TIC should be corrected for diverse effects. There is the definition of measurement point for TIC based on these effects. Because TIC is cylindrical form and has finite volume, the measurement point differs from the geometrical center of TIC. In the standard definitions, the point is called the effective point and recommended that its location is a shift equal to 0.6 times of the inner radius of TIC from the geometrical center. In this work, we examined the accuracy of the definitions of the effective point for TIC by simulation with EGS4. (author)

  2. The psychological analysis of distortions of a behaviour of schoolboys living in various regions

    International Nuclear Information System (INIS)

    Furmanov, I.A.

    1995-01-01

    The necessity of compelled living on contaminated territory and the state social psychological disadaptation, connected with expectation of a remove to other regions, is the reason that the children are in a situation of a prolongation stress, destroying motivational, emotional, strong-willed and moral components of a behaviour regulation. It results to inadequate behaviour reactions to effects of social environment and varying conditions of activity. For the explanation of the reasons of a distortion of behaviour in a critical situation a psychological diagnostics of school teenagers living in the contamination and 'clear' regions was conducted, inter regional distinctions in the behaviour sphere of schoolboys are determined, psychological analysis of the main components of a regulation of a behaviour of teenagers with a various level of an aggressive is conducted. A psychological portrait of schoolboys with various types of behaviour distortions is received. Main directions of a correction work with various categories schoolboys are offered. 8 refs., 1 tab

  3. Characterization of geometrical random uncertainty distribution for a group of patients in radiotherapy

    International Nuclear Information System (INIS)

    Munoz Montplet, C.; Jurado Bruggeman, D.

    2010-01-01

    Geometrical random uncertainty in radiotherapy is usually characterized by a unique value in each group of patients. We propose a novel approach based on a statistically accurate characterization of the uncertainty distribution, thus reducing the risk of obtaining potentially unsafe results in CTV-PTV margins or in the selection of correction protocols.

  4. Impact of loudspeaker nonlinear distortion on personal sound zones

    DEFF Research Database (Denmark)

    Ma, Xiaohui; J. Hegarty, Patrick; Abildgaard Pedersen, Jan

    2018-01-01

    Personal sound zone systems aim at creating multiple listening zones within a shared space with minimum interference between zones, but the performance is often poorer than simulations predict and effects of nonlinear distortion are sometimes audible. This paper assesses the impact of nonlinear...... distortion on sound zones through simulations and measurements performed under anechoic conditions. Two sound zones, one bright and one dark, are created with acoustic contrast control using two loudspeaker arrays driven at 250 Hz. Nonlinear distortion is modelled using second or third order nonlinearities....... Simulations show that nonlinear distortion degrades the acoustic contrast, which is confirmed by experimental measurements. The harmonic distortion is audible in the dark zone. Frequency resolved measurements reveal that harmonic distortion contributes to contrast loss, but nonlinear effects...

  5. Three-dimensional ray tracing for refractive correction of human eye ametropies

    Science.gov (United States)

    Jimenez-Hernandez, J. A.; Diaz-Gonzalez, G.; Trujillo-Romero, F.; Iturbe-Castillo, M. D.; Juarez-Salazar, R.; Santiago-Alvarado, A.

    2016-09-01

    Ametropies of the human eye, are refractive defects hampering the correct imaging on the retina. The most common ways to correct them is by means of spectacles, contact lenses, and modern methods as laser surgery. However, in any case it is very important to identify the ametropia grade for designing the optimum correction action. In the case of laser surgery, it is necessary to define a new shape of the cornea in order to obtain the wanted refractive correction. Therefore, a computational tool to calculate the focal length of the optical system of the eye versus variations on its geometrical parameters is required. Additionally, a clear and understandable visualization of the evaluation process is desirable. In this work, a model of the human eye based on geometrical optics principles is presented. Simulations of light rays coming from a punctual source at six meter from the cornea are shown. We perform a ray-tracing in three dimensions in order to visualize the focusing regions and estimate the power of the optical system. The common parameters of ametropies can be easily modified and analyzed in the simulation by an intuitive graphic user interface.

  6. Source distribution dependent scatter correction for PVI

    International Nuclear Information System (INIS)

    Barney, J.S.; Harrop, R.; Dykstra, C.J.

    1993-01-01

    Source distribution dependent scatter correction methods which incorporate different amounts of information about the source position and material distribution have been developed and tested. The techniques use image to projection integral transformation incorporating varying degrees of information on the distribution of scattering material, or convolution subtraction methods, with some information about the scattering material included in one of the convolution methods. To test the techniques, the authors apply them to data generated by Monte Carlo simulations which use geometric shapes or a voxelized density map to model the scattering material. Source position and material distribution have been found to have some effect on scatter correction. An image to projection method which incorporates a density map produces accurate scatter correction but is computationally expensive. Simpler methods, both image to projection and convolution, can also provide effective scatter correction

  7. Geometrical parton

    Energy Technology Data Exchange (ETDEWEB)

    Ebata, T [Tohoku Univ., Sendai (Japan). Coll. of General Education

    1976-06-01

    The geometrical distribution inferred from the inelastic cross section is assumed to be proportional to the partial waves. The precocious scaling and the Q/sup 2/-dependence of various quantities are treated from the geometrical point of view. It is shown that the approximate conservation of the orbital angular momentum may be a very practical rule to understand the helicity structure of various hadronic and electromagnetic reactions. The rule can be applied to inclusive reactions as well. The model is also applied to large angle processes. Through the discussion, it is suggested that many peculiar properties of the quark-parton can be ascribed to the geometrical effects.

  8. Improved target volume definition in radiosurgery of arteriovenous malformations by stereotactic correlation of MRA, MRI, blood bolus tagging, and functional MRI

    International Nuclear Information System (INIS)

    Schad, L.R.; Bock, M.; Baudendistel, K.; Essig, M.; Debus, J.; Knopp, M.V.; Engenhart, R.; Lorenz, W.J.

    1996-01-01

    The authors report the sterotactic correlation of different MRI-techniques [MR angiography (MRA), MRI, blood bolus tagging (STAR), and functional MRI] in 10 patients with cerebral arteriovenous malformations (AVM) and its application in precision radiotherapy planning. The patient's head was fixed in a stereotactic localization system. By phantom measurements different materials (steel, aluminium, titanium, plastic, wood, ceramics) used for the stereotactic system were tested for mechanical stability and geometrical MR image distortion. All metallic stereotactic rings led to a more or less dramatic geometrical distortion and signal cancellation in the MR images. The best properties - nearly no distortion and high mechanical stability - are provided by a ceramic ring. If necessary, the remaining geometrical MR image distortion can be 'corrected' by calculations based on modeling the distortion as a fourth-order 2D-polynomial. Using this method multimodality matching can be performed automatically as long as all images are acquired in the same examination and the patient is sufficiently immobilized. Precise definition of the target volume could be performed by the radiotherapist either directly in MR images or in calculated projection MR angiograms. As a result, information about the hemodynamics of the AVM was provided by a 3D-phase-contrast flow measurement and a dynamic MRA with the STAR technique leading to an improved definition of the size of the nidus, and the pattern of the venous drainage. In addition, functional MRI was performed in patients with lesions close to the primary motor cortex area leading to an improved definition of structures at risk for high-dose application in radiosurgery. (orig./MG)

  9. Correction of Visual Perception Based on Neuro-Fuzzy Learning for the Humanoid Robot TEO

    Directory of Open Access Journals (Sweden)

    Juan Hernandez-Vicen

    2018-03-01

    Full Text Available New applications related to robotic manipulation or transportation tasks, with or without physical grasping, are continuously being developed. To perform these activities, the robot takes advantage of different kinds of perceptions. One of the key perceptions in robotics is vision. However, some problems related to image processing makes the application of visual information within robot control algorithms difficult. Camera-based systems have inherent errors that affect the quality and reliability of the information obtained. The need of correcting image distortion slows down image parameter computing, which decreases performance of control algorithms. In this paper, a new approach to correcting several sources of visual distortions on images in only one computing step is proposed. The goal of this system/algorithm is the computation of the tilt angle of an object transported by a robot, minimizing image inherent errors and increasing computing speed. After capturing the image, the computer system extracts the angle using a Fuzzy filter that corrects at the same time all possible distortions, obtaining the real angle in only one processing step. This filter has been developed by the means of Neuro-Fuzzy learning techniques, using datasets with information obtained from real experiments. In this way, the computing time has been decreased and the performance of the application has been improved. The resulting algorithm has been tried out experimentally in robot transportation tasks in the humanoid robot TEO (Task Environment Operator from the University Carlos III of Madrid.

  10. Structural Change Accounting with Labor Market Distortions

    OpenAIRE

    Wenbiao Cai

    2014-01-01

    This paper quantifies the relative importance of sectoral productivity and labor market distortions for structural change. I use a model in which labor productivity is the product of TFP and human capital in each sector, but distortions generate wedges in wage per efficiency worker across sectors. I calculate human capital by sector using micro census data, and use the model to infer TFP and distortions such that it replicates structural change in the US, India, Mexico and Brazil between 1960...

  11. Influence of initial state distortion in ion-atom collisions

    Energy Technology Data Exchange (ETDEWEB)

    Ciappina, M F [CONICET and Departamento de FIsica, Universidad Nacional del Sur, 8000 BahIa Blanca (Argentina); Cravero, W R [CONICET and Departamento de FIsica, Universidad Nacional del Sur, 8000 BahIa Blanca (Argentina); Garibotti, C R [CONICET and Division Colisiones Atomicas, Centro Atomico Bariloche, 8400 Bariloche (Argentina)

    2004-05-28

    We have studied the influence of initial state distortion in a single ionization by ion impact. We have taken a continuum distorted wave type distortion and by taking up to the first order in its asymptotic series expansion we build an eikonal-spherical distortion. In this way the influence of each term in the transition amplitude can be stated. This approximation can be considered an intermediate one between the eikonal initial state and the continuum distorted wave approaches for initial state distortion. We have computed doubly differential cross sections for helium ionization by protons and highly charged ions at high and intermediate impact energy. We have also discussed the contribution of the different terms in electron energy spectra, specially in the vicinity of ECC peak. Very good agreement is found with the available experimental data.

  12. Influence of initial state distortion in ion-atom collisions

    International Nuclear Information System (INIS)

    Ciappina, M F; Cravero, W R; Garibotti, C R

    2004-01-01

    We have studied the influence of initial state distortion in a single ionization by ion impact. We have taken a continuum distorted wave type distortion and by taking up to the first order in its asymptotic series expansion we build an eikonal-spherical distortion. In this way the influence of each term in the transition amplitude can be stated. This approximation can be considered an intermediate one between the eikonal initial state and the continuum distorted wave approaches for initial state distortion. We have computed doubly differential cross sections for helium ionization by protons and highly charged ions at high and intermediate impact energy. We have also discussed the contribution of the different terms in electron energy spectra, specially in the vicinity of ECC peak. Very good agreement is found with the available experimental data

  13. Observation of helix associations for insertion of a retinal molecule and distortions of helix structures in bacteriorhodopsin

    Science.gov (United States)

    Urano, Ryo; Okamoto, Yuko

    2015-12-01

    We applied a newly proposed prediction method for membrane protein structures to bacteriorhodopsin that has distorted transmembrane helices in the native structure. This method uses an implicit membrane model, which restricts sampling space during folding in a membrane region, and includes helix bending. Replica-exchange simulations were performed with seven transmembrane helices only without a retinal molecule. Obtained structures were classified into clusters of similar structures, which correspond to local-minimum free energy states. The two lowest free energy states corresponded to a native-like structure with the correct empty space for retinal and a structure with this empty space filled with a helix. Previous experiments of bacteriorhodopsin suggested that association of transmembrane helices enables them to make a room for insertion of a retinal. Our results are consistent with these results. Moreover, distortions of helices in the native-like structures were successfully reproduced. In the distortions, whereas the locations of kinks for all helices were similar to those of Protein Data Bank's data, the amount of bends was more similar for helices away from the retinal than for those close to the retinal in the native structure. This suggests a hypothesis that the amino-acid sequence specifies the location of kinks in transmembrane helices and that the amount of distortions depends on the interactions with the surrounding molecules such as neighboring helices, lipids, and retinal.

  14. Correction factor for hair analysis by PIXE

    International Nuclear Information System (INIS)

    Montenegro, E.C.; Baptista, G.B.; Castro Faria, L.V. de; Paschoa, A.S.

    1980-01-01

    The application of the Particle Induced X-ray Emission (PIXE) technique to analyse quantitatively the elemental composition of hair specimens brings about some difficulties in the interpretation of the data. The present paper proposes a correction factor to account for the effects of the energy loss of the incident particle with penetration depth, and X-ray self-absorption when a particular geometrical distribution of elements in hair is assumed for calculational purposes. The correction factor has been applied to the analysis of hair contents Zn, Cu and Ca as a function of the energy of the incident particle. (orig.)

  15. Correction factor for hair analysis by PIXE

    International Nuclear Information System (INIS)

    Montenegro, E.C.; Baptista, G.B.; Castro Faria, L.V. de; Paschoa, A.S.

    1979-06-01

    The application of the Particle Induced X-ray Emission (PIXE) technique to analyse quantitatively the elemental composition of hair specimens brings about some difficulties in the interpretation of the data. The present paper proposes a correction factor to account for the effects of energy loss of the incident particle with penetration depth, and x-ray self-absorption when a particular geometrical distribution of elements in hair is assumed for calculational purposes. The correction factor has been applied to the analysis of hair contents Zn, Cu and Ca as a function of the energy of the incident particle.(Author) [pt

  16. Density distortion within a rotating body

    International Nuclear Information System (INIS)

    Lanzano, P.

    1975-01-01

    This paper ascertains the distortion of the density distribution within a self-gravitating body in hydrostatic equilibrium under the influence of rotation. For this purpose, the Poisson equation has been solved by using the undistorted density profile within the Laplacian to obtain the distorted density. The Laplacian has been expressed in terms of a system of curvilinear coordinates for which the equipotential surfaces constitute a family of fundamental surfaces. In performing the requisite algebraic manipulations, the Clairaut and Radau equations developed in a previous paper (Lanzano,1974) were utilized to eliminate the derivatives of the elements pertaining to the equipotential surfaces. The density distortion has been obtained up to third-order terms in a small rotational parameter. (Auth.)

  17. Cognitive Distortions in Depressed Women: Trait, or State Dependent?

    Directory of Open Access Journals (Sweden)

    Sedat BATMAZ

    2015-12-01

    Conclusion: The results have revealed that self-criticism, helplessness, hopelessness and preoccupation with danger related distortions had trait-like features, whereas self-blame related distortions were state dependent. This has clinical implications for the psychotherapeutic treatment of cognitive distortions in depression. Specifically, self-criticism related distortions should be managed during cognitive therapy for depression since the other subscales seem rather problematic. [JCBPR 2015; 4(3.000: 147-152

  18. Integral transport multiregion geometrical shadowing factor for the approximate collision probability matrix calculation of infinite closely packed lattices

    International Nuclear Information System (INIS)

    Jowzani-Moghaddam, A.

    1981-01-01

    An integral transport method of calculating the geometrical shadowing factor in multiregion annular cells for infinite closely packed lattices in cylindrical geometry is developed. This analytical method has been programmed in the TPGS code. This method is based upon a consideration of the properties of the integral transport method for a nonuniform body, which together with Bonalumi's approximations allows the determination of the approximate multiregion collision probability matrix for infinite closely packed lattices with sufficient accuracy. The multiregion geometrical shadowing factors have been calculated for variations in fuel pin annular segment rings in a geometry of annular cells. These shadowing factors can then be used in the calculation of neutron transport from one annulus to another in an infinite lattice. The result of this new geometrical shadowing and collision probability matrix are compared with the Dancoff-Ginsburg correction and the probability matrix using constant shadowing on Yankee fuel elements in an infinite lattice. In these cases the Dancoff-Ginsburg correction factor and collision probability matrix using constant shadowing are in difference by at most 6.2% and 6%, respectively

  19. Advanced Machining Toolpath for Low Distortion

    Science.gov (United States)

    2017-02-28

    Advanced Machining Toolpath for Low Distortion FINAL STATUS REPORT Prepared by Brian Becker R&D Technology Manager Third Wave Systems, Inc... Machining Toolpath for Low Distortion December 2016 Contract No.: W911W6-16-P-0044 2 Table of Contents 1.0 EXECUTIVE SUMMARY...2 2.1 Task 1: Collect Details of Machining Lab to Support

  20. Symmetric geometric transfer matrix partial volume correction for PET imaging: principle, validation and robustness

    Science.gov (United States)

    Sattarivand, Mike; Kusano, Maggie; Poon, Ian; Caldwell, Curtis

    2012-11-01

    Limited spatial resolution of positron emission tomography (PET) often requires partial volume correction (PVC) to improve the accuracy of quantitative PET studies. Conventional region-based PVC methods use co-registered high resolution anatomical images (e.g. computed tomography (CT) or magnetic resonance images) to identify regions of interest. Spill-over between regions is accounted for by calculating regional spread functions (RSFs) in a geometric transfer matrix (GTM) framework. This paper describes a new analytically derived symmetric GTM (sGTM) method that relies on spill-over between RSFs rather than between regions. It is shown that the sGTM is mathematically equivalent to Labbe's method; however it is a region-based method rather than a voxel-based method and it avoids handling large matrices. The sGTM method was validated using two three-dimensional (3D) digital phantoms and one physical phantom. A 3D digital sphere phantom with sphere diameters ranging from 5 to 30 mm and a sphere-to-background uptake ratio of 3-to-1 was used. A 3D digital brain phantom was used with four different anatomical regions and a background region with different activities assigned to each region. A physical sphere phantom with the same geometry and uptake as the digital sphere phantom was manufactured and PET-CT images were acquired. Using these three phantoms, the performance of the sGTM method was assessed against that of the GTM method in terms of accuracy, precision, noise propagation and robustness. The robustness was assessed by applying mis-registration errors and errors in estimates of PET point spread function (PSF). In all three phantoms, the results showed that the sGTM method has accuracy similar to that of the GTM method and within 5%. However, the sGTM method showed better precision and noise propagation than the GTM method, especially for spheres smaller than 13 mm. Moreover, the sGTM method was more robust than the GTM method when mis-registration errors or

  1. Symmetric geometric transfer matrix partial volume correction for PET imaging: principle, validation and robustness

    International Nuclear Information System (INIS)

    Sattarivand, Mike; Caldwell, Curtis; Kusano, Maggie; Poon, Ian

    2012-01-01

    Limited spatial resolution of positron emission tomography (PET) often requires partial volume correction (PVC) to improve the accuracy of quantitative PET studies. Conventional region-based PVC methods use co-registered high resolution anatomical images (e.g. computed tomography (CT) or magnetic resonance images) to identify regions of interest. Spill-over between regions is accounted for by calculating regional spread functions (RSFs) in a geometric transfer matrix (GTM) framework. This paper describes a new analytically derived symmetric GTM (sGTM) method that relies on spill-over between RSFs rather than between regions. It is shown that the sGTM is mathematically equivalent to Labbe's method; however it is a region-based method rather than a voxel-based method and it avoids handling large matrices. The sGTM method was validated using two three-dimensional (3D) digital phantoms and one physical phantom. A 3D digital sphere phantom with sphere diameters ranging from 5 to 30 mm and a sphere-to-background uptake ratio of 3-to-1 was used. A 3D digital brain phantom was used with four different anatomical regions and a background region with different activities assigned to each region. A physical sphere phantom with the same geometry and uptake as the digital sphere phantom was manufactured and PET-CT images were acquired. Using these three phantoms, the performance of the sGTM method was assessed against that of the GTM method in terms of accuracy, precision, noise propagation and robustness. The robustness was assessed by applying mis-registration errors and errors in estimates of PET point spread function (PSF). In all three phantoms, the results showed that the sGTM method has accuracy similar to that of the GTM method and within 5%. However, the sGTM method showed better precision and noise propagation than the GTM method, especially for spheres smaller than 13 mm. Moreover, the sGTM method was more robust than the GTM method when mis-registration errors or

  2. Measuring bacterial cells size with AFM

    Directory of Open Access Journals (Sweden)

    Denise Osiro

    2012-03-01

    Full Text Available Atomic Force Microscopy (AFM can be used to obtain high-resolution topographical images of bacteria revealing surface details and cell integrity. During scanning however, the interactions between the AFM probe and the membrane results in distortion of the images. Such distortions or artifacts are the result of geometrical effects related to bacterial cell height, specimen curvature and the AFM probe geometry. The most common artifact in imaging is surface broadening, what can lead to errors in bacterial sizing. Several methods of correction have been proposed to compensate for these artifacts and in this study we describe a simple geometric model for the interaction between the tip (a pyramidal shaped AFM probe and the bacterium (Escherichia coli JM-109 strain to minimize the enlarging effect. Approaches to bacteria immobilization and examples of AFM images analysis are also described.

  3. Geometric Design Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — Purpose: The mission of the Geometric Design Laboratory (GDL) is to support the Office of Safety Research and Development in research related to the geometric design...

  4. Emergent Newtonian dynamics and the geometric origin of mass

    International Nuclear Information System (INIS)

    D’Alessio, Luca; Polkovnikov, Anatoli

    2014-01-01

    We consider a set of macroscopic (classical) degrees of freedom coupled to an arbitrary many-particle Hamiltonian system, quantum or classical. These degrees of freedom can represent positions of objects in space, their angles, shape distortions, magnetization, currents and so on. Expanding their dynamics near the adiabatic limit we find the emergent Newton’s second law (force is equal to the mass times acceleration) with an extra dissipative term. In systems with broken time reversal symmetry there is an additional Coriolis type force proportional to the Berry curvature. We give the microscopic definition of the mass tensor. The mass tensor is related to the non-equal time correlation functions in equilibrium and describes the dressing of the slow degree of freedom by virtual excitations in the system. In the classical (high-temperature) limit the mass tensor is given by the product of the inverse temperature and the Fubini–Study metric tensor determining the natural distance between the eigenstates of the Hamiltonian. For free particles this result reduces to the conventional definition of mass. This finding shows that any mass, at least in the classical limit, emerges from the distortions of the Hilbert space highlighting deep connections between any motion (not necessarily in space) and geometry. We illustrate our findings with four simple examples. -- Highlights: •Derive the macroscopic Newton’s equation from the microscopic many-particle Schrödinger’s equation. •Deep connection between geometry and dynamics. •Geometrical interpretation of the mass of macroscopic object as deformation of Hilbert space. •Microscopic expression for mass and friction tensors

  5. Topics in black-hole physics: geometric constraints on noncollapsing, gravitating systems, and tidal distortions of a Schwarzschild black hole

    International Nuclear Information System (INIS)

    Redmount, I.H.

    1984-01-01

    This dissertation consists of two studies on the general-relativistic theory of black holes. The first work concerns the fundamental issue of black-hole formation: in it geometric constraints are sought on gravitating matter systems, in the special case of axial symmetry, which determine whether or not those systems undergo gravitational collapse to form black holes. The second project deals with mechanical behavior of a black hole: specifically, the tidal deformation of a static black hole is studied by the gravitational fields of external bodies

  6. Profile correction to electron temperature and enhancement factor in soft-x-ray pulse-height-analysis measurements in tokamaks

    International Nuclear Information System (INIS)

    Sesnic, S.; Diesso, M.; Hill, K.; Holland, A.; Pohl, F.

    1988-01-01

    Because soft-x-ray pulse-height-analysis spectra contain chordal information, the electron temperature and the radiation intensity (enhancement factor) measurements do not represent the local values. The correction factors for the electron temperature and the enhancement factor as a function of the temperature and density profile parameters and the energy are obtained. The spectrum distortion due to pulse pileup effects is also evaluated. A set of curves is given from which the distortion of the spectrum can be obtained if the electron temperature, the Be filter thickness, and the electronic parameters of the acquisition system are known. PG 1810,1812 ID 131801CON N X-ray diagnostics TT Profile correction to electron temperature and enhancement factor in soft-x-ray pulse-height-analysis measurements in tokamaks AU S. Sesnic, M. Diesso, K. Hill, and A. Holland LO Princeton University, Plasma Physics Laboratory, P.O. Box 451, Princeton, New Jersey 08543 AU F. Pohl LO Max-Planck Institut fuer Plasmaphysik, 8046-Garching, Federal Republic of Germany SD (Presented on 16 March 1988) AB Because soft-x-ray pulse-height-analysis spectra contain chordal information, the electron temperature and the radiation intensity (enhancement factor) measurements do not represent the local values. The correction factors for the electron temperature and the enhancement factor as a function of the temperature and density profile parameters and the energy are obtained. The spectrum distortion due to pulse pileup effects is also evaluated. A set of curves is given from which the distortion of the spectrum can be obtained if the electron tempe

  7. Finite-Q22 Corrections to Parity-Violating DIS

    International Nuclear Information System (INIS)

    T. Hobbs; W. Melnitchouk

    2008-01-01

    Parity-violating deep inelastic scattering (PVDIS) has been proposed as an important new tool to extract the flavor and isospin dependence of parton distributions in the nucleon. We discuss finite-Q 2 effects in PVDIS asymmetries arising from subleading kinematical corrections and longitudinal contributions to the gamma Z interference. For the proton, these need to be accounted for when extracting the d/u ratio at large x. For the deuteron, the finite-Q 2 corrections can distort the effects of charge symmetry violation in parton distributions, or signals for physics beyond the standard model. We further explore the dependence of PVDIS asymmetries for polarized targets on the u and d helicity distributions at large x

  8. Electron Transfer and Geometric Conversion of Co-NO Moiety in Saddled Porphyrins: Implications for Trigger Role of Tetrapyrrole Distortion.

    Science.gov (United States)

    Tang, Min; Yang, Yan; Zhang, Shaowei; Chen, Jiafu; Zhang, Jian; Zhou, Zaichun; Liu, Qiuhua

    2018-01-02

    The electrons of NO and Co are strongly delocalized in normal {Co-NO} 8 species. In this work, {Co-NO} 8 complexes are induced to convert from (Co II ) +• -NO • to Co III -NO - by a core contraction of 0.06 Å in saddled cobalt(II) porphyrins. This intramolecular electron transfer mechanism indicates that nonplanarity of porphyrin is involved in driving conversion of the NO units from electrophilic NO • as a bent geometry to nucleophilic NO - as a linear geometry. This implies that distortion acts as a trigger in enzymes containing tetrapyrrole. The electronic behaviors of the Co II ions and Co-NO moieties were confirmed by X-ray crystallography, EPR spectroscopy, theoretical calculation, UV-vis and IR spectroscopy, and electrochemistry.

  9. A Cognitive Distortions and Deficits Model of Suicide Ideation

    Directory of Open Access Journals (Sweden)

    Laura L. Fazakas-DeHoog

    2017-05-01

    Full Text Available Although cognitive distortions and deficits are known risk factors for the development and escalation of suicide ideation and behaviour, no empirical work has examined how these variables interact to predict suicide ideation. The current study proposes an integrative model of cognitive distortions (hopelessness and negative evaluations of self and future and deficits (problem solving deficits, problem solving avoidance, and cognitive rigidity. To test the integrity of this model, a sample of 397 undergraduate students completed measures of deficits, distortions, and current suicide ideation. A structural equation model demonstrated excellent fit, and findings indicated that only distortions have a direct effect on suicidal thinking, whereas cognitive deficits may exert their effects on suicide ideation via their reciprocal relation with distortions. Findings underscore the importance of both cognitive distortions and deficits for understanding suicidality, which may have implications for preventative efforts and treatment.

  10. Bilateral Symmetry of Distortions of Tactile Size Perception.

    Science.gov (United States)

    Longo, Matthew R; Ghosh, Arko; Yahya, Tasneem

    2015-01-01

    The perceived distance between touches on the limbs is generally bigger for distances oriented across the width of the limb than for distances oriented along the length of the limb. The present study aimed to investigate the coherence of such distortions of tactile size perception across different skin surfaces. We investigated distortions of tactile size perception on the dorsal and palmar surfaces of both the left and right hands as well as the forehead. Participants judged which of two tactile distances felt larger. One distance was aligned with the proximodistal axis (along the body), the other with the mediolateral axis (across the body). Clear distortions were found on all five skin surfaces, with stimuli oriented across the width of the body being perceived as farther apart than those oriented along the length of the body. Consistent with previous results, distortions were smaller on the palmar than on the dorsal hand surface. Distortion on the forehead was intermediate between the dorsal and palmar surfaces. There were clear correlations between distortion on the left and right hands, for both the dorsal and palmar skin surfaces. In contrast, within each hand, there was no significant correlation between the two skin surfaces. Distortion on the forehead was not significantly correlated with that on any of the other skin surfaces. These results provide evidence for bilaterally symmetric representations underlying tactile size perception. © The Author(s) 2015.

  11. Thermodynamically constrained correction to ab initio equations of state

    International Nuclear Information System (INIS)

    French, Martin; Mattsson, Thomas R.

    2014-01-01

    We show how equations of state generated by density functional theory methods can be augmented to match experimental data without distorting the correct behavior in the high- and low-density limits. The technique is thermodynamically consistent and relies on knowledge of the density and bulk modulus at a reference state and an estimation of the critical density of the liquid phase. We apply the method to four materials representing different classes of solids: carbon, molybdenum, lithium, and lithium fluoride. It is demonstrated that the corrected equations of state for both the liquid and solid phases show a significantly reduced dependence of the exchange-correlation functional used.

  12. Effects of Landsat 5 Thematic Mapper and Landsat 7 Enhanced Thematic Mapper plus radiometric and geometric calibrations and corrections on landscape characterization

    Science.gov (United States)

    Vogelmann, James E.; Helder, Dennis; Morfitt, Ron; Choate, Michael J.; Merchant, James W.; Bulley, Henry

    2001-01-01

    The Thematic Mapper (TM) instruments onboard Landsats 4 and 5 provide high-quality imagery appropriate for many different applications, including land cover mapping, landscape ecology, and change detection. Precise calibration was considered to be critical to the success of the Landsat 7 mission and, thus, issues of calibration were given high priority during the development of the Enhanced Thematic Mapper Plus (ETM+). Data sets from the Landsat 5 TM are not routinely corrected for a number of radiometric and geometric artifacts, including memory effect, gain/bias, and interfocal plane misalignment. In the current investigation, the effects of correcting vs. not correcting these factors were investigated for several applications. Gain/bias calibrations were found to have a greater impact on most applications than did memory effect calibrations. Correcting interfocal plane offsets was found to have a moderate effect on applications. On June 2, 1999, Landsats 5 and 7 data were acquired nearly simultaneously over a study site in the Niobrara, NE area. Field radiometer data acquired at that site were used to facilitate crosscalibrations of Landsats 5 and 7 data. Current findings and results from previous investigations indicate that the internal calibrator of Landsat 5 TM tracked instrument gain well until 1988. After this, the internal calibrator diverged from the data derived from vicarious calibrations. Results from this study also indicate very good agreement between prelaunch measurements and vicarious calibration data for all Landsat 7 reflective bands except Band 4. Values are within about 3.5% of each other, except for Band 4, which differs by 10%. Coefficient of variation (CV) values derived from selected targets in the imagery were also analyzed. The Niobrara Landsat 7 imagery was found to have lower CV values than Landsat 5 data, implying that lower levels of noise characterize Landsat 7 data than current Landsat 5 data. It was also found that following

  13. Why do animals differ in their susceptibility to geometrical illusions?

    Science.gov (United States)

    Feng, Lynna C; Chouinard, Philippe A; Howell, Tiffani J; Bennett, Pauleen C

    2017-04-01

    In humans, geometrical illusions are thought to reflect mechanisms that are usually helpful for seeing the world in a predictable manner. These mechanisms deceive us given the right set of circumstances, correcting visual input where a correction is not necessary. Investigations of non-human animals' susceptibility to geometrical illusions have yielded contradictory results, suggesting that the underlying mechanisms with which animals see the world may differ across species. In this review, we first collate studies showing that different species are susceptible to specific illusions in the same or reverse direction as humans. Based on a careful assessment of these findings, we then propose several ecological and anatomical factors that may affect how a species perceives illusory stimuli. We also consider the usefulness of this information for determining whether sight in different species might be more similar to human sight, being influenced by contextual information, or to how machines process and transmit information as programmed. Future testing in animals could provide new theoretical insights by focusing on establishing dissociations between stimuli that may or may not alter perception in a particular species. This information could improve our understanding of the mechanisms behind illusions, but also provide insight into how sight is subjectively experienced by different animals, and the degree to which vision is innate versus acquired, which is difficult to examine in humans.

  14. Impact of a Geometric Correction for Proximal Flow Constraint on the Assessment of Mitral Regurgitation Severity Using the Proximal Flow Convergence Method.

    Science.gov (United States)

    Jang, Jeong Yoon; Kang, Joon-Won; Yang, Dong Hyun; Lee, Sahmin; Sun, Byung Joo; Kim, Dae-Hee; Song, Jong-Min; Kang, Duk-Hyun; Song, Jae-Kwan

    2018-03-01

    Overestimation of the severity of mitral regurgitation (MR) by the proximal isovelocity surface area (PISA) method has been reported. We sought to test whether angle correction (AC) of the constrained flow field is helpful to eliminate overestimation in patients with eccentric MR. In a total of 33 patients with MR due to prolapse or flail mitral valve, both echocardiography and cardiac magnetic resonance image (CMR) were performed to calculate regurgitant volume (RV). In addition to RV by conventional PISA (RV PISA ), convergence angle (α) was measured from 2-dimensional Doppler color flow maps and RV was corrected by multiplying by α/180 (RV AC ). RV measured by CMR (RV CMR ) was used as a gold standard, which was calculated by the difference between total stroke volume measured by planimetry of the short axis slices and aortic stroke volume by phase-contrast image. The correlation between RV CMR and RV by echocardiography was modest [RV CMR vs. RV PISA (r = 0.712, p < 0.001) and RV CMR vs. RV AC (r = 0.766, p < 0.001)]. However, RV PISA showed significant overestimation (RV PISA - RV CMR = 50.6 ± 40.6 mL vs. RV AC - RV CMR = 7.7 ± 23.4 mL, p < 0.001). The overall accuracy of RV PISA for diagnosis of severe MR, defined as RV ≥ 60 mL, was 57.6% (19/33), whereas it increased to 84.8% (28/33) by using RV AC ( p = 0.028). Conventional PISA method tends to provide falsely large RV in patients with eccentric MR and a simple geometric AC of the proximal constraint flow largely eliminates overestimation.

  15. Systems and methods for mirror mounting with minimized distortion

    Science.gov (United States)

    Antonille, Scott R. (Inventor); Wallace, Thomas E. (Inventor); Content, David A. (Inventor); Wake, Shane W. (Inventor)

    2012-01-01

    A method for mounting a mirror for use in a telescope includes attaching the mirror to a plurality of adjustable mounts; determining a distortion in the mirror caused by the plurality adjustable mounts, and, if the distortion is determined to be above a predetermined level: adjusting one or more of the adjustable mounts; and determining the distortion in the mirror caused by the adjustable mounts; and in the event the determined distortion is determined to be at or below the predetermined level, rigidizing the adjustable mounts.

  16. Simulation of Distortion and Residual Stress Development During Heat Treatment of Steel Castings

    Energy Technology Data Exchange (ETDEWEB)

    Beckermann, Christoph; Carlson, Kent

    2011-07-22

    Heat treatment and associated processing, such as quenching, are critical during high strength steel casting production. These processes must be managed closely to prevent thermal and residual stresses that may result in distortion, cracking (particularly after machining), re-work, and weld repair. The risk of casting distortion limits aggressive quenching that can be beneficial to the process and yield an improved outcome. As a result of these distortions, adjustments must be made to the casting or pattern design, or tie bars must be added. Straightening castings after heat treatments can be both time-consuming and expensive. Residual stresses may reduce a casting's overall service performance, possibly resulting in catastrophic failure. Stress relieving may help, but expends additional energy in the process. Casting software is very limited in predicting distortions during heat treatment, so corrective measures most often involve a tedious trial-and-error procedure. An extensive review of existing heat treatment residual stress and distortion modeling revealed that it is vital to predict the phase transformations and microstructure of the steel along with the thermal stress development during heat treatment. After reviewing the state-of-the-art in heat treatment residual stress and distortion modeling, an existing commercial code was selected because of its advanced capabilities in predicting phase transformations, the evolving microstructure and related properties along with thermal stress development during heat treatment. However, this software was developed for small parts created from forgings or machined stock, and not for steel castings. Therefore, its predictive capabilities for heat treatment of steel castings were investigated. Available experimental steel casting heat treatment data was determined to be of insufficient detail and breadth, and so new heat treatment experiments were designed and performed, casting and heat treating modified versions

  17. Geometric calibration between PET scanner and structured light scanner

    DEFF Research Database (Denmark)

    Kjer, Hans Martin; Olesen, Oline Vinter; Paulsen, Rasmus Reinhold

    2011-01-01

    Head movements degrade the image quality of high resolution Positron Emission Tomography (PET) brain studies through blurring and artifacts. Manny image reconstruction methods allows for motion correction if the head position is tracked continuously during the study. Our method for motion tracking...... is a structured light scanner placed just above the patient tunnel on the High Resolution Research Tomograph (HRRT, Siemens). It continuously registers point clouds of a part of the patient's face. The relative motion is estimated as the rigid transformation between frames. A geometric calibration between...

  18. Modelling the Perceptual Components of Loudspeaker Distortion

    DEFF Research Database (Denmark)

    Olsen, Sune L.; Agerkvist, Finn T.; MacDonald, Ewen

    2016-01-01

    While non-linear distortion in loudspeakers decreases audio quality, the perceptual consequences can vary substantially. This paper investigates the metric Rnonlin [1] which was developed to predict subjective measurements of sound quality in nonlinear systems. The generalisability of the metric...... the perceptual consequences of non-linear distortion....

  19. Geometric Potential Assessment for ZY3-02 Triple Linear Array Imagery

    Directory of Open Access Journals (Sweden)

    Kai Xu

    2017-06-01

    Full Text Available ZiYuan3-02 (ZY3-02 is the first remote sensing satellite for the development of China’s civil space infrastructure (CCSI and the second satellite in the ZiYuan3 series; it was launched successfully on 30 May 2016, aboard the CZ-4B rocket at the Taiyuan Satellite Launch Center (TSLC in China. Core payloads of ZY3-02 include a triple linear array camera (TLC and a multi-spectral camera, and this equipment will be used to acquire space geographic information with high-resolution and stereoscopic observations. Geometric quality is a key factor that affects the performance and potential of satellite imagery. For the purpose of evaluating comprehensively the geometric potential of ZY3-02, this paper introduces the method used for geometric calibration of the TLC onboard the satellite and a model for sensor corrected (SC products that serve as basic products delivered to users. Evaluation work was conducted by making a full assessment of the geometric performance. Furthermore, images of six regions and corresponding reference data were collected to implement the geometric calibration technique and evaluate the resulting geometric accuracy. Experimental results showed that the direct location performance and internal accuracy of SC products increased remarkably after calibration, and the planimetric and vertical accuracies with relatively few ground control points (GCPs were demonstrated to be better than 2.5 m and 2 m, respectively. Additionally, the derived digital surface model (DSM accuracy was better than 3 m (RMSE for flat terrain and 5 m (RMSE for mountainous terrain. However, given that several variations such as changes in the thermal environment can alter the camera’s installation angle, geometric performance will vary with the geographical location and imaging time changes. Generally, ZY3-02 can be used for 1:50,000 stereo mapping and can produce (and update larger-scale basic geographic information products.

  20. Off-shell distortions of multichannel atomic processes

    Science.gov (United States)

    Barrachina, R. O.; Clauser, C. F.

    2017-10-01

    Any multichannel problem can be reduced to a succession of two-body events. However, these basic building blocks of many-body theories do not correspond to elastic processes but are off-the-energy-shell. In view of this difficulty, the great majority of the Distorted-Wave models includes a subsidiary approximation where these off-shell terms are arbitrarily forced to lie on the energy shell. At a first glance, since the energy deficiency is negligible for high enough velocities, the on-shell assumption seems to be completely justified. However, for the case of Coulomb interactions, the two-body off-shell distortions have branch-point singularities on the on-shell limit. In this article we demonstrate that these singularities might produce sizeable distortions of multiple scattering amplitudes, mainly when dealing with ion-ion collisions. Finally, we propose a method of including these distortions that might lead to better results that removing them completely.

  1. The effect of photometric and geometric context on photometric and geometric lightness effects.

    Science.gov (United States)

    Lee, Thomas Y; Brainard, David H

    2014-01-24

    We measured the lightness of probe tabs embedded at different orientations in various contextual images presented on a computer-controlled stereo display. Two background context planes met along a horizontal roof-like ridge. Each plane was a graphic rendering of a set of achromatic surfaces with the simulated illumination for each plane controlled independently. Photometric context was varied by changing the difference in simulated illumination intensity between the two background planes. Geometric context was varied by changing the angle between them. We parsed the data into separate photometric effects and geometric effects. For fixed geometry, varying photometric context led to linear changes in both the photometric and geometric effects. Varying geometric context did not produce a statistically reliable change in either the photometric or geometric effects.

  2. Automated Orthorectification of VHR Satellite Images by SIFT-Based RPC Refinement

    Directory of Open Access Journals (Sweden)

    Hakan Kartal

    2018-06-01

    Full Text Available Raw remotely sensed images contain geometric distortions and cannot be used directly for map-based applications, accurate locational information extraction or geospatial data integration. A geometric correction process must be conducted to minimize the errors related to distortions and achieve the desired location accuracy before further analysis. A considerable number of images might be needed when working over large areas or in temporal domains in which manual geometric correction requires more labor and time. To overcome these problems, new algorithms have been developed to make the geometric correction process autonomous. The Scale Invariant Feature Transform (SIFT algorithm is an image matching algorithm used in remote sensing applications that has received attention in recent years. In this study, the effects of the incidence angle, surface topography and land cover (LC characteristics on SIFT-based automated orthorectification were investigated at three different study sites with different topographic conditions and LC characteristics using Pleiades very high resolution (VHR images acquired at different incidence angles. The results showed that the location accuracy of the orthorectified images increased with lower incidence angle images. More importantly, the topographic characteristics had no observable impacts on the location accuracy of SIFT-based automated orthorectification, and the results showed that Ground Control Points (GCPs are mainly concentrated in the “Forest” and “Semi Natural Area” LC classes. A multi-thread code was designed to reduce the automated processing time, and the results showed that the process performed 7 to 16 times faster using an automated approach. Analyses performed on various spectral modes of multispectral data showed that the arithmetic data derived from pan-sharpened multispectral images can be used in automated SIFT-based RPC orthorectification.

  3. Attenuation correction for SPECT

    International Nuclear Information System (INIS)

    Hosoba, Minoru

    1986-01-01

    Attenuation correction is required for the reconstruction of a quantitative SPECT image. A new method for detecting body contours, which are important for the correction of tissue attenuation, is presented. The effect of body contours, detected by the newly developed method, on the reconstructed images was evaluated using various techniques for attenuation correction. The count rates in the specified region of interest in the phantom image by the Radial Post Correction (RPC) method, the Weighted Back Projection (WBP) method, Chang's method were strongly affected by the accuracy of the contours, as compared to those by Sorenson's method. To evaluate the effect of non-uniform attenuators on the cardiac SPECT, computer simulation experiments were performed using two types of models, the uniform attenuator model (UAM) and the non-uniform attenuator model (NUAM). The RPC method showed the lowest relative percent error (%ERROR) in UAM (11 %). However, 20 to 30 percent increase in %ERROR was observed for NUAM reconstructed with the RPC, WBP, and Chang's methods. Introducing an average attenuation coefficient (0.12/cm for Tc-99m and 0.14/cm for Tl-201) in the RPC method decreased %ERROR to the levels for UAM. Finally, a comparison between images, which were obtained by 180 deg and 360 deg scans and reconstructed from the RPC method, showed that the degree of the distortion of the contour of the simulated ventricles in the 180 deg scan was 15 % higher than that in the 360 deg scan. (Namekawa, K.)

  4. Modeling Kinetics of Distortion in Porous Bi-layered Structures

    DEFF Research Database (Denmark)

    Tadesse Molla, Tesfaye; Frandsen, Henrik Lund; Bjørk, Rasmus

    2013-01-01

    because of different sintering rates of the materials resulting in undesired distortions of the component. An analytical model based on the continuum theory of sintering has been developed to describe the kinetics of densification and distortion in the sintering processes. A new approach is used...... to extract the material parameters controlling shape distortion through optimizing the model to experimental data of free shrinkage strains. The significant influence of weight of the sample (gravity) on the kinetics of distortion is taken in to consideration. The modeling predictions indicate good agreement...

  5. Harmonic distortion in microwave photonic filters.

    Science.gov (United States)

    Rius, Manuel; Mora, José; Bolea, Mario; Capmany, José

    2012-04-09

    We present a theoretical and experimental analysis of nonlinear microwave photonic filters. Far from the conventional condition of low modulation index commonly used to neglect high-order terms, we have analyzed the harmonic distortion involved in microwave photonic structures with periodic and non-periodic frequency responses. We show that it is possible to design microwave photonic filters with reduced harmonic distortion and high linearity even under large signal operation.

  6. CMB spectral distortions as solutions to the Boltzmann equations

    Energy Technology Data Exchange (ETDEWEB)

    Ota, Atsuhisa, E-mail: a.ota@th.phys.titech.ac.jp [Department of Physics, Tokyo Institute of Technology, Tokyo 152-8551 (Japan)

    2017-01-01

    We propose to re-interpret the cosmic microwave background spectral distortions as solutions to the Boltzmann equation. This approach makes it possible to solve the second order Boltzmann equation explicitly, with the spectral y distortion and the momentum independent second order temperature perturbation, while generation of μ distortion cannot be explained even at second order in this framework. We also extend our method to higher order Boltzmann equations systematically and find new type spectral distortions, assuming that the collision term is linear in the photon distribution functions, namely, in the Thomson scattering limit. As an example, we concretely construct solutions to the cubic order Boltzmann equation and show that the equations are closed with additional three parameters composed of a cubic order temperature perturbation and two cubic order spectral distortions. The linear Sunyaev-Zel'dovich effect whose momentum dependence is different from the usual y distortion is also discussed in the presence of the next leading order Kompaneets terms, and we show that higher order spectral distortions are also generated as a result of the diffusion process in a framework of higher order Boltzmann equations. The method may be applicable to a wider class of problems and has potential to give a general prescription to non-equilibrium physics.

  7. Distortional solutions for loaded semi-discretized thin-walled beams

    DEFF Research Database (Denmark)

    Andreassen, Michael Joachim; Jönsson, Jeppe

    2012-01-01

    distortional displacement fields which decouple the reduced order differential equations. In this process the cross section is discretized into finite cross-section elements, and the natural distortional modes as well as the related axial variations are found as solutions to the established coupled fourth...... order homogeneous differential equations of GBT.In this paper the non-homogeneous distortional differential equations of GBT are formulated using this novel semi-discretization process. Transforming these non-homogeneous distortional differential equations into the natural eigenmode space by using...... the distortional modal matrix found for the homogeneous system, we get the uncoupled set of differential equations including the distributed loads. This uncoupling is very important in GBT, since the shear stiffness contribution from St. Venant torsional shear stress as well as “Bredt's shear flow” cannot...

  8. Self-absorption corrections for well-type germanium detectors

    International Nuclear Information System (INIS)

    Appleby, P.G.; Richardson, N.; Nolan, P.J.

    1992-01-01

    Corrections for self-absorption are of vital importance to accurate determination by gamma spectrometry of radionuclides such as 210 Pb, 241 Am and 234 Th which emit low energy gamma radiation. A simple theoretical model for determining the necessary corrections for well-type germanium detectors is presented. In this model, self-absorption factors are expressed in terms of the mass attenuation coefficient of the sample and a parameter characterising the well geometry. Experimental measurements of self-absorption are used to evaluate the model and to determine a semi-empirical algorithm for improved estimates of the geometrical parameter. (orig.)

  9. Lattice shear distortions in fluorite structure oxides

    International Nuclear Information System (INIS)

    Faber, J. Jr.; Mueller, M.H.; Hitterman, R.L.

    1979-01-01

    Crystallographic shear distortions have been observed in fluorite structure, single crystals of UO 2 and Zr(Ca)O 2 /sub-x/ by neutron-diffraction techniques. These distortions localize on the oxygen sublattice and do not require the presence of an external strain. The internal rearrangement mode in UO 2 is a transverse, zone boundary q vector = 2π/a (0.5, 0.0) deformation with amplitude 0.014 A. In Zr(Ca)O/sub 2-x/, the mode is a longitudinal, q vector = 2-/a (0,0,0.5) deformation with amplitude 0.23 A. Cation-anion elastic interactions dominate in selecting the nature of the internal distortion

  10. Field of view extension and truncation correction for MR-based human attenuation correction in simultaneous MR/PET imaging

    International Nuclear Information System (INIS)

    Blumhagen, Jan O.; Ladebeck, Ralf; Fenchel, Matthias; Braun, Harald; Quick, Harald H.; Faul, David; Scheffler, Klaus

    2014-01-01

    Purpose: In quantitative PET imaging, it is critical to accurately measure and compensate for the attenuation of the photons absorbed in the tissue. While in PET/CT the linear attenuation coefficients can be easily determined from a low-dose CT-based transmission scan, in whole-body MR/PET the computation of the linear attenuation coefficients is based on the MR data. However, a constraint of the MR-based attenuation correction (AC) is the MR-inherent field-of-view (FoV) limitation due to static magnetic field (B 0 ) inhomogeneities and gradient nonlinearities. Therefore, the MR-based human AC map may be truncated or geometrically distorted toward the edges of the FoV and, consequently, the PET reconstruction with MR-based AC may be biased. This is especially of impact laterally where the patient arms rest beside the body and are not fully considered. Methods: A method is proposed to extend the MR FoV by determining an optimal readout gradient field which locally compensates B 0 inhomogeneities and gradient nonlinearities. This technique was used to reduce truncation in AC maps of 12 patients, and the impact on the PET quantification was analyzed and compared to truncated data without applying the FoV extension and additionally to an established approach of PET-based FoV extension. Results: The truncation artifacts in the MR-based AC maps were successfully reduced in all patients, and the mean body volume was thereby increased by 5.4%. In some cases large patient-dependent changes in SUV of up to 30% were observed in individual lesions when compared to the standard truncated attenuation map. Conclusions: The proposed technique successfully extends the MR FoV in MR-based attenuation correction and shows an improvement of PET quantification in whole-body MR/PET hybrid imaging. In comparison to the PET-based completion of the truncated body contour, the proposed method is also applicable to specialized PET tracers with little uptake in the arms and might reduce the

  11. Geometric group theory

    CERN Document Server

    Druţu, Cornelia

    2018-01-01

    The key idea in geometric group theory is to study infinite groups by endowing them with a metric and treating them as geometric spaces. This applies to many groups naturally appearing in topology, geometry, and algebra, such as fundamental groups of manifolds, groups of matrices with integer coefficients, etc. The primary focus of this book is to cover the foundations of geometric group theory, including coarse topology, ultralimits and asymptotic cones, hyperbolic groups, isoperimetric inequalities, growth of groups, amenability, Kazhdan's Property (T) and the Haagerup property, as well as their characterizations in terms of group actions on median spaces and spaces with walls. The book contains proofs of several fundamental results of geometric group theory, such as Gromov's theorem on groups of polynomial growth, Tits's alternative, Stallings's theorem on ends of groups, Dunwoody's accessibility theorem, the Mostow Rigidity Theorem, and quasiisometric rigidity theorems of Tukia and Schwartz. This is the f...

  12. Coulomb Distortion in the Inelastic Regime

    Energy Technology Data Exchange (ETDEWEB)

    Patricia Solvignon, Dave Gaskell, John Arrington

    2009-09-01

    The Coulomb distortion effects have been for a long time neglected in deep inelastic scattering for the good reason that the incident energies were very high. But for energies in the range of earlier data from SLAC or at JLab, the Coulomb distortion could have the potential consequence of affecting the A-dependence of the EMC effect and of the longitudinal to transverse virtual photon absorption cross section ratio $R(x,Q^2)$.

  13. 3D geometric modeling and simulation of laser propagation through turbulence with plenoptic functions

    Science.gov (United States)

    Wu, Chensheng; Nelson, William; Davis, Christopher C.

    2014-10-01

    Plenoptic functions are functions that preserve all the necessary light field information of optical events. Theoretical work has demonstrated that geometric based plenoptic functions can serve equally well in the traditional wave propagation equation known as the "scalar stochastic Helmholtz equation". However, in addressing problems of 3D turbulence simulation, the dominant methods using phase screen models have limitations both in explaining the choice of parameters (on the transverse plane) in real-world measurements, and finding proper correlations between neighboring phase screens (the Markov assumption breaks down). Though possible corrections to phase screen models are still promising, the equivalent geometric approach based on plenoptic functions begins to show some advantages. In fact, in these geometric approaches, a continuous wave problem is reduced to discrete trajectories of rays. This allows for convenience in parallel computing and guarantees conservation of energy. Besides the pairwise independence of simulated rays, the assigned refractive index grids can be directly tested by temperature measurements with tiny thermoprobes combined with other parameters such as humidity level and wind speed. Furthermore, without loss of generality one can break the causal chain in phase screen models by defining regional refractive centers to allow rays that are less affected to propagate through directly. As a result, our work shows that the 3D geometric approach serves as an efficient and accurate method in assessing relevant turbulence problems with inputs of several environmental measurements and reasonable guesses (such as Cn 2 levels). This approach will facilitate analysis and possible corrections in lateral wave propagation problems, such as image de-blurring, prediction of laser propagation over long ranges, and improvement of free space optic communication systems. In this paper, the plenoptic function model and relevant parallel algorithm computing

  14. COD correction for laser cooling at S-LSR

    International Nuclear Information System (INIS)

    Souda, Hikaru; Fujimoto, Shinji; Tongu, Hiromu; Shirai, Toshiyuki; Tanabe, Mikio; Ishikawa, Takehiro; Nakao, Masao; Ikegami, Masahiro; Wakita, Akihisa; Iwata, Soma; Fujimoto, Tetsuya; Takeuchi, Takeshi; Noda, Koji; Noda, Akira

    2008-01-01

    A closed orbit is corrected for single-turn injection to perform laser cooling experiments of 40 keV 24 Mg + beam at the small laser-equipped storage ring (S-LSR). Closed orbit distortion (COD) corrections have been carried out using a downhill simplex method, and CODs of less than ±0.5mm have been achieved throughout the whole circumference. The injection orbit and the CODs are optimized to pass through the two aperture holes in the alignment targets located in the laser cooling section with an algorithm to maximize beam lifetime. The CODs at the aperture holes are reduced to be less than ±0.2mm, assuring an overlap between the laser and the 24 Mg + ion beam.

  15. Correcting for static shift of magnetotelluric data with airborne electromagnetic measurements: a case study from Rathlin Basin, Northern Ireland

    Directory of Open Access Journals (Sweden)

    R. Delhaye

    2017-05-01

    Full Text Available Galvanic distortions of magnetotelluric (MT data, such as the static-shift effect, are a known problem that can lead to incorrect estimation of resistivities and erroneous modelling of geometries with resulting misinterpretation of subsurface electrical resistivity structure. A wide variety of approaches have been proposed to account for these galvanic distortions, some depending on the target area, with varying degrees of success. The natural laboratory for our study is a hydraulically permeable volume of conductive sediment at depth, the internal resistivity structure of which can be used to estimate reservoir viability for geothermal purposes; however, static-shift correction is required in order to ensure robust and precise modelling accuracy.We present here a possible method to employ frequency–domain electromagnetic data in order to correct static-shift effects, illustrated by a case study from Northern Ireland. In our survey area, airborne frequency domain electromagnetic (FDEM data are regionally available with high spatial density. The spatial distributions of the derived static-shift corrections are analysed and applied to the uncorrected MT data prior to inversion. Two comparative inversion models are derived, one with and one without static-shift corrections, with instructive results. As expected from the one-dimensional analogy of static-shift correction, at shallow model depths, where the structure is controlled by a single local MT site, the correction of static-shift effects leads to vertical scaling of resistivity–thickness products in the model, with the corrected model showing improved correlation to existing borehole wireline resistivity data. In turn, as these vertical scalings are effectively independent of adjacent sites, lateral resistivity distributions are also affected, with up to half a decade of resistivity variation between the models estimated at depths down to 2000 m. Simple estimation of differences in bulk

  16. Tomosynthesis-detected Architectural Distortion: Management Algorithm with Radiologic-Pathologic Correlation.

    Science.gov (United States)

    Durand, Melissa A; Wang, Steven; Hooley, Regina J; Raghu, Madhavi; Philpotts, Liane E

    2016-01-01

    As use of digital breast tomosynthesis becomes increasingly widespread, new management challenges are inevitable because tomosynthesis may reveal suspicious lesions not visible at conventional two-dimensional (2D) full-field digital mammography. Architectural distortion is a mammographic finding associated with a high positive predictive value for malignancy. It is detected more frequently at tomosynthesis than at 2D digital mammography and may even be occult at conventional 2D imaging. Few studies have focused on tomosynthesis-detected architectural distortions to date, and optimal management of these distortions has yet to be well defined. Since implementing tomosynthesis at our institution in 2011, we have learned some practical ways to assess architectural distortion. Because distortions may be subtle, tomosynthesis localization tools plus improved visualization of adjacent landmarks are crucial elements in guiding mammographic identification of elusive distortions. These same tools can guide more focused ultrasonography (US) of the breast, which facilitates detection and permits US-guided tissue sampling. Some distortions may be sonographically occult, in which case magnetic resonance imaging may be a reasonable option, both to increase diagnostic confidence and to provide a means for image-guided biopsy. As an alternative, tomosynthesis-guided biopsy, conventional stereotactic biopsy (when possible), or tomosynthesis-guided needle localization may be used to achieve tissue diagnosis. Practical uses for tomosynthesis in evaluation of architectural distortion are highlighted, potential complications are identified, and a working algorithm for management of tomosynthesis-detected architectural distortion is proposed. (©)RSNA, 2016.

  17. Asymmetric Anterior Distraction for Transversely Distorted Maxilla and Midfacial Anteroposterior Deficiency in a Patient With Cleft Lip/Palate: Two-Stage Surgical Approach.

    Science.gov (United States)

    Hirata, Kae; Tanikawa, Chihiro; Aikawa, Tomonao; Ishihama, Kohji; Kogo, Mikihiko; Iida, Seiji; Yamashiro, Takashi

    2016-07-01

    The present report describes a male patient with a unilateral cleft lip and palate who presented with midfacial anteroposterior and transverse deficiency. Correction involved a two-stage surgical-orthodontic approach: asymmetric anterior distraction of the segmented maxilla followed by two-jaw surgery (LeFort I and bilateral sagittal splitting ramus osteotomies). The present case demonstrates that the asymmetric elongation of the maxilla with anterior distraction is an effective way to correct a transversely distorted alveolar form and midfacial anteroposterior deficiency. Furthermore, successful tooth movement was demonstrated in the new bone created by distraction.

  18. The evolution of costly mate choice against segregation distorters.

    Science.gov (United States)

    Manser, Andri; Lindholm, Anna K; Weissing, Franz J

    2017-12-01

    The evolution of female preference for male genetic quality remains a controversial topic in sexual selection research. One well-known problem, known as the lek paradox, lies in understanding how variation in genetic quality is maintained in spite of natural selection and sexual selection against low-quality alleles. Here, we theoretically investigate a scenario where females pay a direct fitness cost to avoid males carrying an autosomal segregation distorter. We show that preference evolution is greatly facilitated under such circumstances. Because the distorter is transmitted in a non-Mendelian fashion, it can be maintained in the population despite directional sexual selection. The preference helps females avoid fitness costs associated with the distorter. Interestingly, we find that preference evolution is limited if the choice allele induces a very strong preference or if distortion is very strong. Moreover, the preference can only persist in the presence of a signal that reliably indicates a male's distorter genotype. Hence, even in a system where the lek paradox does not play a major role, costly preferences can only spread under specific circumstances. We discuss the importance of distorter systems for the evolution of costly female choice and potential implications for the use of artificial distorters in pest control. © 2017 The Author(s). Evolution © 2017 The Society for the Study of Evolution.

  19. TLS FIELD DATA BASED INTENSITY CORRECTION FOR FOREST ENVIRONMENTS

    Directory of Open Access Journals (Sweden)

    J. Heinzel

    2016-06-01

    Full Text Available Terrestrial laser scanning (TLS is increasingly used for forestry applications. Besides the three dimensional point coordinates, the 'intensity' of the reflected signal plays an important role in forestry and vegetation studies. The benefit of the signal intensity is caused by the wavelength of the laser that is within the near infrared (NIR for most scanners. The NIR is highly indicative for various vegetation characteristics. However, the intensity as recorded by most terrestrial scanners is distorted by both external and scanner specific factors. Since details about system internal alteration of the signal are often unknown to the user, model driven approaches are impractical. On the other hand, existing data driven calibration procedures require laborious acquisition of separate reference datasets or areas of homogenous reflection characteristics from the field data. In order to fill this gap, the present study introduces an approach to correct unwanted intensity variations directly from the point cloud of the field data. The focus is on the variation over range and sensor specific distortions. Instead of an absolute calibration of the values, a relative correction within the dataset is sufficient for most forestry applications. Finally, a method similar to time series detrending is presented with the only pre-condition of a relative equal distribution of forest objects and materials over range. Our test data covers 50 terrestrial scans captured with a FARO Focus 3D S120 scanner using a laser wavelength of 905 nm. Practical tests demonstrate that our correction method removes range and scanner based alterations of the intensity.

  20. Oxygen 1s excitation and tetragonal distortion from core-hole effect in BaTiO3

    Science.gov (United States)

    Bugnet, Matthieu; Radtke, Guillaume; Botton, Gianluigi A.

    2013-11-01

    The accurate description of the O 1s excitation in BaTiO3 has been elusive so far. In this Rapid Communication, the electronic structure and the high-resolution electron energy-loss near-edge structures of the O K edge in tetragonal BaTiO3 are investigated using first-principles calculations. The results demonstrate a clear correlation between the broadening of the lower energy fine structure and the anisotropic effects induced by the core-hole potential, which are directly related to the structural distortion occurring in tetragonal BaTiO3. Moreover, we show that a significant improvement of the description of higher-lying structures can be obtained when correcting the energy position of the Ba 4f states. This demonstrates that the O 1s spectrum can be a very effective probe of the distortion and changes in the local electronic structure, and be used as a sensitive tool for studying new materials and ferroelectric transitions.

  1. On geometrized gravitation theories

    International Nuclear Information System (INIS)

    Logunov, A.A.; Folomeshkin, V.N.

    1977-01-01

    General properties of the geometrized gravitation theories have been considered. Geometrization of the theory is realized only to the extent that by necessity follows from an experiment (geometrization of the density of the matter Lagrangian only). Aor a general case the gravitation field equations and the equations of motion for matter are formulated in the different Riemann spaces. A covariant formulation of the energy-momentum conservation laws is given in an arbitrary geometrized theory. The noncovariant notion of ''pseudotensor'' is not required in formulating the conservation laws. It is shown that in the general case (i.e., when there is an explicit dependence of the matter Lagrangian density on the covariant derivatives) a symmetric energy-momentum tensor of the matter is explicitly dependent on the curvature tensor. There are enlisted different geometrized theories that describe a known set of the experimental facts. The properties of one of the versions of the quasilinear geometrized theory that describes the experimental facts are considered. In such a theory the fundamental static spherically symmetrical solution has a singularity only in the coordinate origin. The theory permits to create a satisfactory model of the homogeneous nonstationary Universe

  2. Distortion dependent intersystem crossing

    DEFF Research Database (Denmark)

    Stephansen, Anne Boutrup; Sølling, Theis Ivan

    2017-01-01

    . The effect is observed to increase in the presence of methyl-groups on the pinnacle carbon-atoms, where largest extents of r and p orbital-mixing are observed. This is fully consistent with the time-resolved spectroscopy data: Toluene and p-xylene show evidence for ultrafast triplet formation competing......The competition between ultrafast intersystem crossing and internal conversion in benzene, toluene, and p-xylene is investigated with time-resolved photoelectron spectroscopy and quantum chemical calculations. By exciting to S2 out-of-plane symmetry breaking, distortions are activated at early...... times whereupon spin-forbidden intersystem crossing becomes (partly) allowed. Natural bond orbital analysis suggests that the pinnacle carbon atoms distorting from the aromatic plane change hybridization between the planar Franck-Condon geometry and the deformed (boat-shaped) S2 equilibrium geometry...

  3. The dynamics of sensory buffers: geometric, spatial, and experience-dependent shaping of iconic memory.

    Science.gov (United States)

    Graziano, Martin; Sigman, Mariano

    2008-05-23

    When a stimulus is presented, its sensory trace decays rapidly, lasting for approximately 1000 ms. This brief and labile memory, referred as iconic memory, serves as a buffer before information is transferred to working memory and executive control. Here we explored the effect of different factors--geometric, spatial, and experience--with respect to the access and the maintenance of information in iconic memory and the progressive distortion of this memory. We studied performance in a partial report paradigm, a design wherein recall of only part of a stimulus array is required. Subjects had to report the identity of a letter in a location that was cued in a variable delay after the stimulus onset. Performance decayed exponentially with time, and we studied the different parameters (time constant, zero-delay value, and decay amplitude) as a function of the different factors. We observed that experience (determined by letter frequency) affected the access to iconic memory but not the temporal decay constant. On the contrary, spatial position affected the temporal course of delay. The entropy of the error distribution increased with time reflecting a progressive morphological distortion of the iconic buffer. We discuss our results on the context of a model of information access to executive control and how it is affected by learning and attention.

  4. Applications of the second-order achromat concept to the design of particle accelerators

    International Nuclear Information System (INIS)

    Brown, K.L.; Servranckx, R.V.

    1985-05-01

    A property of the second-order achromat, whereby dipole and sextupole families may be inserted into a lattice for chromatic corrections without introducing second-order geometrical (on momentum) optical distortions, has been incorporated in several new particle accelerator designs. These include the SLC at SLAC, LEP at CERN, the EROS pulse stretcher ring at Saskatoon, the CEBAF ring at SURA, and the MIT ring

  5. Point- and curve-based geometric conflation

    KAUST Repository

    Ló pez-Vá zquez, C.; Manso Callejo, M.A.

    2013-01-01

    Geometric conflation is the process undertaken to modify the coordinates of features in dataset A in order to match corresponding ones in dataset B. The overwhelming majority of the literature considers the use of points as features to define the transformation. In this article we present a procedure to consider one-dimensional curves also, which are commonly available as Global Navigation Satellite System (GNSS) tracks, routes, coastlines, and so on, in order to define the estimate of the displacements to be applied to each object in A. The procedure involves three steps, including the partial matching of corresponding curves, the computation of some analytical expression, and the addition of a correction term in order to satisfy basic cartographic rules. A numerical example is presented. © 2013 Copyright Taylor and Francis Group, LLC.

  6. Geometric metamorphosis.

    Science.gov (United States)

    Niethammer, Marc; Hart, Gabriel L; Pace, Danielle F; Vespa, Paul M; Irimia, Andrei; Van Horn, John D; Aylward, Stephen R

    2011-01-01

    Standard image registration methods do not account for changes in image appearance. Hence, metamorphosis approaches have been developed which jointly estimate a space deformation and a change in image appearance to construct a spatio-temporal trajectory smoothly transforming a source to a target image. For standard metamorphosis, geometric changes are not explicitly modeled. We propose a geometric metamorphosis formulation, which explains changes in image appearance by a global deformation, a deformation of a geometric model, and an image composition model. This work is motivated by the clinical challenge of predicting the long-term effects of traumatic brain injuries based on time-series images. This work is also applicable to the quantification of tumor progression (e.g., estimating its infiltrating and displacing components) and predicting chronic blood perfusion changes after stroke. We demonstrate the utility of the method using simulated data as well as scans from a clinical traumatic brain injury patient.

  7. The research of a gyro-stabilized platform and POS application technology in airborne remote sensing

    Science.gov (United States)

    Xu, Jiang; Du, Qi

    2009-07-01

    The distortion of the collected images usually takes place since the attitude changes along with the flying aerocraft on airborne remote sensing. In order to get original images without distortion, it is necessary to use professional gyro-stabilized platform. In addition to this, another solution of correcting the original image distortion is to utilize later geometric rectification using position & orientation system ( POS ) data. The third way is to utilize medium-accuracy stabilized platform to control the distortion at a tolerant range, and then make use of the data obtained by high-solution posture measure system to correct the low-quality remote sensing images. The third way which takes advantage of both techniques is better than using only one of the two other ways. This paper introduces several kinds of structural forms of gyro-stabilized platforms, and POS acquiring instruments respectively. Then, the essay will make some analysis of their advantages and disadvantages, key technologies and the application experiment of the third method. After the analysis, the thesis discusses the design of the gyro-stabilized platform. The thesis provides crucial information not only for the application technology of gyro-stabilized platform and POS but also for future development.

  8. Economic choices reveal probability distortion in macaque monkeys.

    Science.gov (United States)

    Stauffer, William R; Lak, Armin; Bossaerts, Peter; Schultz, Wolfram

    2015-02-18

    Economic choices are largely determined by two principal elements, reward value (utility) and probability. Although nonlinear utility functions have been acknowledged for centuries, nonlinear probability weighting (probability distortion) was only recently recognized as a ubiquitous aspect of real-world choice behavior. Even when outcome probabilities are known and acknowledged, human decision makers often overweight low probability outcomes and underweight high probability outcomes. Whereas recent studies measured utility functions and their corresponding neural correlates in monkeys, it is not known whether monkeys distort probability in a manner similar to humans. Therefore, we investigated economic choices in macaque monkeys for evidence of probability distortion. We trained two monkeys to predict reward from probabilistic gambles with constant outcome values (0.5 ml or nothing). The probability of winning was conveyed using explicit visual cues (sector stimuli). Choices between the gambles revealed that the monkeys used the explicit probability information to make meaningful decisions. Using these cues, we measured probability distortion from choices between the gambles and safe rewards. Parametric modeling of the choices revealed classic probability weighting functions with inverted-S shape. Therefore, the animals overweighted low probability rewards and underweighted high probability rewards. Empirical investigation of the behavior verified that the choices were best explained by a combination of nonlinear value and nonlinear probability distortion. Together, these results suggest that probability distortion may reflect evolutionarily preserved neuronal processing. Copyright © 2015 Stauffer et al.

  9. The correction of electron lens aberrations

    Energy Technology Data Exchange (ETDEWEB)

    Hawkes, P.W., E-mail: peter.hawkes@cemes.fr

    2015-09-15

    The progress of electron lens aberration correction from about 1990 onwards is chronicled. Reasonably complete lists of publications on this and related topics are appended. A present for Max Haider and Ondrej Krivanek in the year of their 65th birthdays. By a happy coincidence, this review was completed in the year that both Max Haider and Ondrej Krivanek reached the age of 65. It is a pleasure to dedicate it to the two leading actors in the saga of aberration corrector design and construction. They would both wish to associate their colleagues with such a tribute but it is the names of Haider and Krivanek (not forgetting Joachim Zach) that will remain in the annals of electron optics, next to that of Harald Rose. I am proud to know that both regard me as a friend as well as a colleague. - Highlights: • Geometrical aberration correction. • Chromatic aberration correction. • 50 pm resolution. • High-resolution electron energy-loss spectroscopy. • Extensive bibliographies.

  10. The correction of electron lens aberrations

    International Nuclear Information System (INIS)

    Hawkes, P.W.

    2015-01-01

    The progress of electron lens aberration correction from about 1990 onwards is chronicled. Reasonably complete lists of publications on this and related topics are appended. A present for Max Haider and Ondrej Krivanek in the year of their 65th birthdays. By a happy coincidence, this review was completed in the year that both Max Haider and Ondrej Krivanek reached the age of 65. It is a pleasure to dedicate it to the two leading actors in the saga of aberration corrector design and construction. They would both wish to associate their colleagues with such a tribute but it is the names of Haider and Krivanek (not forgetting Joachim Zach) that will remain in the annals of electron optics, next to that of Harald Rose. I am proud to know that both regard me as a friend as well as a colleague. - Highlights: • Geometrical aberration correction. • Chromatic aberration correction. • 50 pm resolution. • High-resolution electron energy-loss spectroscopy. • Extensive bibliographies

  11. The Impact of Correcting Cognitive Distortions in Reducing Depression and the Sense of Insecurity among a Sample of Female Refugee Adolescents

    Science.gov (United States)

    Mhaidat, Fatin; ALharbi, Bassam H. M.

    2016-01-01

    This study aimed at identifying the level of depression and sense of insecurity among a sample of female refugee adolescents, and the impact of an indicative program for reducing cognitive distortions in reducing depression and their sense of insecurity. The study sample consisted of 220 female refugee adolescents, 7th to 1st secondary stage, at…

  12. Artefacts in geometric phase analysis of compound materials

    Energy Technology Data Exchange (ETDEWEB)

    Peters, Jonathan J.P., E-mail: j.j.p.peters@warwick.ac.uk [Department of Physics, University of Warwick, Gibbet Hill Road, Coventry CV4 7AL (United Kingdom); Beanland, Richard; Alexe, Marin [Department of Physics, University of Warwick, Gibbet Hill Road, Coventry CV4 7AL (United Kingdom); Cockburn, John W.; Revin, Dmitry G.; Zhang, Shiyong Y. [Department of Physics and Astronomy, University of Sheffield, Hounsfield Road, Sheffield S3 7RH (United Kingdom); Sanchez, Ana M., E-mail: a.m.sanchez@warwick.ac.uk [Department of Physics, University of Warwick, Gibbet Hill Road, Coventry CV4 7AL (United Kingdom)

    2015-10-15

    The geometric phase analysis (GPA) algorithm is known as a robust and straightforward technique that can be used to measure lattice strains in high resolution transmission electron microscope (TEM) images. It is also attractive for analysis of aberration-corrected scanning TEM (ac-STEM) images that resolve every atom column, since it uses Fourier transforms and does not require real-space peak detection and assignment to appropriate sublattices. Here it is demonstrated that, in ac-STEM images of compound materials with compositionally distinct atom columns, an additional geometric phase is present in the Fourier transform. If the structure changes from one area to another in the image (e.g. across an interface), the change in this additional phase will appear as a strain in conventional GPA, even if there is no lattice strain. Strategies to avoid this pitfall are outlined. - Highlights: • GPA is shown to produce incorrect strains when applied to images of compound materials. • A mathematical description is laid out for why GPA can produce artefacts. • The artefact is demonstrated using experimental and simulated data. • A ‘rule’ is set to avoid this artefact in GPA.

  13. Word Recognition for Temporally and Spectrally Distorted Materials

    DEFF Research Database (Denmark)

    Smith, Sherri L.; Pichora-Fuller, Margaret Kathleen; Wilson, Richard H.

    2012-01-01

    listeners with near-normal hearing and hearing loss performed best in the unaltered condition, followed by the jitter and smear conditions, with the poorest performance in the combined jitter-smear condition in both quiet and noise. Overall, listeners with near-normal hearing performed better than listeners...... to predict group differences, but not the effects of distortion. Individual differences in performance were similar across all distortion conditions with both age and hearing loss being implicated. The speech materials needed to be both spectrally and temporally distorted to mimic the effects of age...

  14. Rate-distortion theory and human perception.

    Science.gov (United States)

    Sims, Chris R

    2016-07-01

    The fundamental goal of perception is to aid in the achievement of behavioral objectives. This requires extracting and communicating useful information from noisy and uncertain sensory signals. At the same time, given the complexity of sensory information and the limitations of biological information processing, it is necessary that some information must be lost or discarded in the act of perception. Under these circumstances, what constitutes an 'optimal' perceptual system? This paper describes the mathematical framework of rate-distortion theory as the optimal solution to the problem of minimizing the costs of perceptual error subject to strong constraints on the ability to communicate or transmit information. Rate-distortion theory offers a general and principled theoretical framework for developing computational-level models of human perception (Marr, 1982). Models developed in this framework are capable of producing quantitatively precise explanations for human perceptual performance, while yielding new insights regarding the nature and goals of perception. This paper demonstrates the application of rate-distortion theory to two benchmark domains where capacity limits are especially salient in human perception: discrete categorization of stimuli (also known as absolute identification) and visual working memory. A software package written for the R statistical programming language is described that aids in the development of models based on rate-distortion theory. Copyright © 2016 The Author. Published by Elsevier B.V. All rights reserved.

  15. Impact of geometric uncertainties on dose calculations for intensity modulated radiation therapy of prostate cancer

    Science.gov (United States)

    Jiang, Runqing

    Intensity-modulated radiation therapy (IMRT) uses non-uniform beam intensities within a radiation field to provide patient-specific dose shaping, resulting in a dose distribution that conforms tightly to the planning target volume (PTV). Unavoidable geometric uncertainty arising from patient repositioning and internal organ motion can lead to lower conformality index (CI) during treatment delivery, a decrease in tumor control probability (TCP) and an increase in normal tissue complication probability (NTCP). The CI of the IMRT plan depends heavily on steep dose gradients between the PTV and organ at risk (OAR). Geometric uncertainties reduce the planned dose gradients and result in a less steep or "blurred" dose gradient. The blurred dose gradients can be maximized by constraining the dose objective function in the static IMRT plan or by reducing geometric uncertainty during treatment with corrective verification imaging. Internal organ motion and setup error were evaluated simultaneously for 118 individual patients with implanted fiducials and MV electronic portal imaging (EPI). A Gaussian probability density function (PDF) is reasonable for modeling geometric uncertainties as indicated by the 118 patients group. The Gaussian PDF is patient specific and group standard deviation (SD) should not be used for accurate treatment planning for individual patients. In addition, individual SD should not be determined or predicted from small imaging samples because of random nature of the fluctuations. Frequent verification imaging should be employed in situations where geometric uncertainties are expected. Cumulative PDF data can be used for re-planning to assess accuracy of delivered dose. Group data is useful for determining worst case discrepancy between planned and delivered dose. The margins for the PTV should ideally represent true geometric uncertainties. The measured geometric uncertainties were used in this thesis to assess PTV coverage, dose to OAR, equivalent

  16. Nonlinear analysis of magnetospheric data Part I. Geometric characteristics of the AE index time series and comparison with nonlinear surrogate data

    Directory of Open Access Journals (Sweden)

    G. P. Pavlos

    1999-01-01

    Full Text Available A long AE index time series is used as a crucial magnetospheric quantity in order to study the underlying dynainics. For this purpose we utilize methods of nonlinear and chaotic analysis of time series. Two basic components of this analysis are the reconstruction of the experimental tiine series state space trajectory of the underlying process and the statistical testing of an null hypothesis. The null hypothesis against which the experimental time series are tested is that the observed AE index signal is generated by a linear stochastic signal possibly perturbed by a static nonlinear distortion. As dis ' ' ating statistics we use geometrical characteristics of the reconstructed state space (Part I, which is the work of this paper and dynamical characteristics (Part II, which is the work a separate paper, and "nonlinear" surrogate data, generated by two different techniques which can mimic the original (AE index signal. lie null hypothesis is tested for geometrical characteristics which are the dimension of the reconstructed trajectory and some new geometrical parameters introduced in this work for the efficient discrimination between the nonlinear stochastic surrogate data and the AE index. Finally, the estimated geometric characteristics of the magnetospheric AE index present new evidence about the nonlinear and low dimensional character of the underlying magnetospheric dynamics for the AE index.

  17. Geological Corrections in Gravimetry

    Science.gov (United States)

    Mikuška, J.; Marušiak, I.

    2015-12-01

    Applying corrections for the known geology to gravity data can be traced back into the first quarter of the 20th century. Later on, mostly in areas with sedimentary cover, at local and regional scales, the correction known as gravity stripping has been in use since the mid 1960s, provided that there was enough geological information. Stripping at regional to global scales became possible after releasing the CRUST 2.0 and later CRUST 1.0 models in the years 2000 and 2013, respectively. Especially the later model provides quite a new view on the relevant geometries and on the topographic and crustal densities as well as on the crust/mantle density contrast. Thus, the isostatic corrections, which have been often used in the past, can now be replaced by procedures working with an independent information interpreted primarily from seismic studies. We have developed software for performing geological corrections in space domain, based on a-priori geometry and density grids which can be of either rectangular or spherical/ellipsoidal types with cells of the shapes of rectangles, tesseroids or triangles. It enables us to calculate the required gravitational effects not only in the form of surface maps or profiles but, for instance, also along vertical lines, which can shed some additional light on the nature of the geological correction. The software can work at a variety of scales and considers the input information to an optional distance from the calculation point up to the antipodes. Our main objective is to treat geological correction as an alternative to accounting for the topography with varying densities since the bottoms of the topographic masses, namely the geoid or ellipsoid, generally do not represent geological boundaries. As well we would like to call attention to the possible distortions of the corrected gravity anomalies. This work was supported by the Slovak Research and Development Agency under the contract APVV-0827-12.

  18. The role of visual similarity and memory in body model distortions.

    Science.gov (United States)

    Saulton, Aurelie; Longo, Matthew R; Wong, Hong Yu; Bülthoff, Heinrich H; de la Rosa, Stephan

    2016-02-01

    Several studies have shown that the perception of one's own hand size is distorted in proprioceptive localization tasks. It has been suggested that those distortions mirror somatosensory anisotropies. Recent research suggests that non-corporeal items also show some spatial distortions. In order to investigate the psychological processes underlying the localization task, we investigated the influences of visual similarity and memory on distortions observed on corporeal and non-corporeal items. In experiment 1, participants indicated the location of landmarks on: their own hand, a rubber hand (rated as most similar to the real hand), and a rake (rated as least similar to the real hand). Results show no significant differences between rake and rubber hand distortions but both items were significantly less distorted than the hand. Experiments 2 and 3 explored the role of memory in spatial distance judgments of the hand, the rake and the rubber hand. Spatial representations of items measured in experiments 2 and 3 were also distorted but showed the tendency to be smaller than in localization tasks. While memory and visual similarity seem to contribute to explain qualitative similarities in distortions between the hand and non-corporeal items, those factors cannot explain the larger magnitude observed in hand distortions. Copyright © 2015. Published by Elsevier B.V.

  19. Fisheye image rectification using spherical and digital distortion models

    Science.gov (United States)

    Li, Xin; Pi, Yingdong; Jia, Yanling; Yang, Yuhui; Chen, Zhiyong; Hou, Wenguang

    2018-02-01

    Fisheye cameras have been widely used in many applications including close range visual navigation and observation and cyber city reconstruction because its field of view is much larger than that of a common pinhole camera. This means that a fisheye camera can capture more information than a pinhole camera in the same scenario. However, the fisheye image contains serious distortion, which may cause trouble for human observers in recognizing the objects within. Therefore, in most practical applications, the fisheye image should be rectified to a pinhole perspective projection image to conform to human cognitive habits. The traditional mathematical model-based methods cannot effectively remove the distortion, but the digital distortion model can reduce the image resolution to some extent. Considering these defects, this paper proposes a new method that combines the physical spherical model and the digital distortion model. The distortion of fisheye images can be effectively removed according to the proposed approach. Many experiments validate its feasibility and effectiveness.

  20. Distortions in the output signals of conventional spectrum analyzers

    International Nuclear Information System (INIS)

    Njau, E.C.

    1988-08-01

    We show that the output signals of conventional spectrum analysers contain distortions which basically originate from the signal processing performed inside the analysers' frequency convertors. Total elimination of these distortions through normal filtering techniques is difficult owing to the closeness of some of their frequencies to the corresponding frequencies of the required signals. Simple design adjustments that can minimize these distortions are suggested. (author). 7 refs, 2 figs

  1. Self-corrective T-loop design for differential space closure.

    Science.gov (United States)

    Viecilli, Rodrigo F

    2006-01-01

    The current approach to measuring T-loop force systems in patients requiring differential anchorage does not consider active unit angulations and steps during space closure. The angulations and steps during movement introduced by rotation can considerably modify the force system acting on the teeth. In this study, geometric modifications were determined during controlled tipping of the 6 anterior teeth, where there was no movement of the posterior teeth, thus configuring a type A anchorage situation. An optimal beta-titanium alloy 0.017 x 0.025-in T-loop spring was designed by using a simulation performed with LOOP software (dHAL Orthodontic Software, Athens, Greece) to allow compensation for anterior unit-position effect on the final force system. The force systems produced by this T-loop spring with and without geometric correction of the brackets have significant differences that should be considered in the segmented arch approach to space closure. The effects of steps, angles, and vertical forces were combined to produce an ideal T-loop design that would provide a more determinate force system. The effects and force systems are estimates based on simplified locations of the centers of resistance, assuming relatively constant behavior of the centers of rotation. These simplifications might differ slightly from what happens in vivo. The finite element method or an accurate spring tester capable of reproducing the geometric corrections should be used to ensure a precise force system.

  2. Appraisal Distortions and Intimate Partner Violence: Gender, Power, and Interaction

    Science.gov (United States)

    Whiting, Jason B.; Oka, Megan; Fife, Stephen T.

    2012-01-01

    In relationships characterized by control, abuse, or violence, many appraisal distortions occur including denial and minimization. However, the nature of the distortion varies depending on the individual's role in the relationship (i.e., abuser or victim). Reducing these distortions is an important component in treatment success and involves…

  3. Dynamical vs. geometric anisotropy in relativistic heavy-ion collisions. Which one prevails?

    Energy Technology Data Exchange (ETDEWEB)

    Bravina, L.V. [University of Oslo, Department of Physics, Oslo (Norway); National Research Nuclear University ' ' MEPhI' ' (Moscow Engineering Physics Institute), Moscow (Russian Federation); Lokhtin, I.P.; Malinina, L.V.; Petrushanko, S.V.; Snigirev, A.M. [Lomonosov Moscow State University, Skobeltsyn Institute of Nuclear Physics, Moscow (Russian Federation); Zabrodin, E.E. [Lomonosov Moscow State University, Skobeltsyn Institute of Nuclear Physics, Moscow (Russian Federation); University of Oslo, Department of Physics, Oslo (Norway); National Research Nuclear University ' ' MEPhI' ' (Moscow Engineering Physics Institute), Moscow (Russian Federation)

    2017-11-15

    We study the influence of geometric and dynamical anisotropies on the development of flow harmonics and, simultaneously, on the second- and third-order oscillations of femtoscopy radii. The analysis is done within the Monte Carlo event generator HYDJET++, which was extended to dynamical triangular deformations. It is shown that the merely geometric anisotropy provides the results which anticorrelate with the experimental observations of either v{sub 2} (or v{sub 3}) or second-order (or third-order) oscillations of the femtoscopy radii. Decays of resonances significantly increase the emitting areas but do not change the phases of the radii oscillations. In contrast to the spatial deformations, the dynamical anisotropy alone provides the correct qualitative description of the flow and the femtoscopy observables simultaneously. However, one needs both types of the anisotropy to match quantitatively the experimental data. (orig.)

  4. Testing inflation and curvaton scenarios with CMB distortions

    International Nuclear Information System (INIS)

    Clesse, Sébastien; Garbrecht, Björn; Zhu, Yi

    2014-01-01

    Prior to recombination, Silk damping causes the dissipation of energy from acoustic waves into the monopole of the Cosmic Microwave Background (CMB), resulting in spectral distortions. These can be used to probe the primordial scalar power spectrum on smaller scales than it is possible with CMB anisotropies. An enhancement of power on these scales is nevertheless required for the resulting distortions to be detectable by future experiments like PIXIE. In this paper, we examine all 49 single-field inflation models listed by Martin et al. in the Encyclopaedia Inflationaris [1] and find that only one of these may lead to a detectable level of distortions in a tuned region of its parameter space, namely the original hybrid model. Three effective multi-field scenarios are also studied: with softly and suddenly turning trajectories, and with a mild waterfall trajectory. Softly turning trajectories do not induce distortions at any detectable level, whereas a sudden turn in the field space or a mild waterfall trajectory predicts a peak (plus damped oscillations in the sudden turn case) in the scalar power spectrum, which can lead to an observable amount of CMB distortions. Finally, another scenario leading to potentially detectable distortions involves a curvaton whose blue spectrum is subdominant on CMB angular scales and overtakes the inflaton spectrum on smaller scales. In this case however, we show that the bounds from ultra compact minihaloes are not satisfied. Expectations for an ultimate PRISM-class experiment characterized by an improvement in sensitivity by a factor of ten are discussed for some models

  5. Testing inflation and curvaton scenarios with CMB distortions

    Science.gov (United States)

    Clesse, Sébastien; Garbrecht, Björn; Zhu, Yi

    2014-10-01

    Prior to recombination, Silk damping causes the dissipation of energy from acoustic waves into the monopole of the Cosmic Microwave Background (CMB), resulting in spectral distortions. These can be used to probe the primordial scalar power spectrum on smaller scales than it is possible with CMB anisotropies. An enhancement of power on these scales is nevertheless required for the resulting distortions to be detectable by future experiments like PIXIE. In this paper, we examine all 49 single-field inflation models listed by Martin et al. in the Encyclopaedia Inflationaris [1] and find that only one of these may lead to a detectable level of distortions in a tuned region of its parameter space, namely the original hybrid model. Three effective multi-field scenarios are also studied: with softly and suddenly turning trajectories, and with a mild waterfall trajectory. Softly turning trajectories do not induce distortions at any detectable level, whereas a sudden turn in the field space or a mild waterfall trajectory predicts a peak (plus damped oscillations in the sudden turn case) in the scalar power spectrum, which can lead to an observable amount of CMB distortions. Finally, another scenario leading to potentially detectable distortions involves a curvaton whose blue spectrum is subdominant on CMB angular scales and overtakes the inflaton spectrum on smaller scales. In this case however, we show that the bounds from ultra compact minihaloes are not satisfied. Expectations for an ultimate PRISM-class experiment characterized by an improvement in sensitivity by a factor of ten are discussed for some models.

  6. Limitations of a convolution method for modeling geometric uncertainties in radiation therapy. I. The effect of shift invariance

    International Nuclear Information System (INIS)

    Craig, Tim; Battista, Jerry; Van Dyk, Jake

    2003-01-01

    Convolution methods have been used to model the effect of geometric uncertainties on dose delivery in radiation therapy. Convolution assumes shift invariance of the dose distribution. Internal inhomogeneities and surface curvature lead to violations of this assumption. The magnitude of the error resulting from violation of shift invariance is not well documented. This issue is addressed by comparing dose distributions calculated using the Convolution method with dose distributions obtained by Direct Simulation. A comparison of conventional Static dose distributions was also made with Direct Simulation. This analysis was performed for phantom geometries and several clinical tumor sites. A modification to the Convolution method to correct for some of the inherent errors is proposed and tested using example phantoms and patients. We refer to this modified method as the Corrected Convolution. The average maximum dose error in the calculated volume (averaged over different beam arrangements in the various phantom examples) was 21% with the Static dose calculation, 9% with Convolution, and reduced to 5% with the Corrected Convolution. The average maximum dose error in the calculated volume (averaged over four clinical examples) was 9% for the Static method, 13% for Convolution, and 3% for Corrected Convolution. While Convolution can provide a superior estimate of the dose delivered when geometric uncertainties are present, the violation of shift invariance can result in substantial errors near the surface of the patient. The proposed Corrected Convolution modification reduces errors near the surface to 3% or less

  7. Computer-aided diagnosis of mammographic masses using geometric verification-based image retrieval

    Science.gov (United States)

    Li, Qingliang; Shi, Weili; Yang, Huamin; Zhang, Huimao; Li, Guoxin; Chen, Tao; Mori, Kensaku; Jiang, Zhengang

    2017-03-01

    Computer-Aided Diagnosis of masses in mammograms is an important indicator of breast cancer. The use of retrieval systems in breast examination is increasing gradually. In this respect, the method of exploiting the vocabulary tree framework and the inverted file in the mammographic masse retrieval have been proved high accuracy and excellent scalability. However it just considered the features in each image as a visual word and had ignored the spatial configurations of features. It greatly affect the retrieval performance. To overcome this drawback, we introduce the geometric verification method to retrieval in mammographic masses. First of all, we obtain corresponding match features based on the vocabulary tree framework and the inverted file. After that, we grasps the main point of local similarity characteristic of deformations in the local regions by constructing the circle regions of corresponding pairs. Meanwhile we segment the circle to express the geometric relationship of local matches in the area and generate the spatial encoding strictly. Finally we judge whether the matched features are correct or not, based on verifying the all spatial encoding are whether satisfied the geometric consistency. Experiments show the promising results of our approach.

  8. Geometric approximation algorithms

    CERN Document Server

    Har-Peled, Sariel

    2011-01-01

    Exact algorithms for dealing with geometric objects are complicated, hard to implement in practice, and slow. Over the last 20 years a theory of geometric approximation algorithms has emerged. These algorithms tend to be simple, fast, and more robust than their exact counterparts. This book is the first to cover geometric approximation algorithms in detail. In addition, more traditional computational geometry techniques that are widely used in developing such algorithms, like sampling, linear programming, etc., are also surveyed. Other topics covered include approximate nearest-neighbor search, shape approximation, coresets, dimension reduction, and embeddings. The topics covered are relatively independent and are supplemented by exercises. Close to 200 color figures are included in the text to illustrate proofs and ideas.

  9. Geometric Mixing, Peristalsis, and the Geometric Phase of the Stomach.

    Science.gov (United States)

    Arrieta, Jorge; Cartwright, Julyan H E; Gouillart, Emmanuelle; Piro, Nicolas; Piro, Oreste; Tuval, Idan

    2015-01-01

    Mixing fluid in a container at low Reynolds number--in an inertialess environment--is not a trivial task. Reciprocating motions merely lead to cycles of mixing and unmixing, so continuous rotation, as used in many technological applications, would appear to be necessary. However, there is another solution: movement of the walls in a cyclical fashion to introduce a geometric phase. We show using journal-bearing flow as a model that such geometric mixing is a general tool for using deformable boundaries that return to the same position to mix fluid at low Reynolds number. We then simulate a biological example: we show that mixing in the stomach functions because of the "belly phase," peristaltic movement of the walls in a cyclical fashion introduces a geometric phase that avoids unmixing.

  10. Geometric Mixing, Peristalsis, and the Geometric Phase of the Stomach.

    Directory of Open Access Journals (Sweden)

    Jorge Arrieta

    Full Text Available Mixing fluid in a container at low Reynolds number--in an inertialess environment--is not a trivial task. Reciprocating motions merely lead to cycles of mixing and unmixing, so continuous rotation, as used in many technological applications, would appear to be necessary. However, there is another solution: movement of the walls in a cyclical fashion to introduce a geometric phase. We show using journal-bearing flow as a model that such geometric mixing is a general tool for using deformable boundaries that return to the same position to mix fluid at low Reynolds number. We then simulate a biological example: we show that mixing in the stomach functions because of the "belly phase," peristaltic movement of the walls in a cyclical fashion introduces a geometric phase that avoids unmixing.

  11. Distortion-Based Link Adaptation for Wireless Video Transmission

    Directory of Open Access Journals (Sweden)

    Andrew Nix

    2008-06-01

    Full Text Available Wireless local area networks (WLANs such as IEEE 802.11a/g utilise numerous transmission modes, each providing different throughputs and reliability levels. Most link adaptation algorithms proposed in the literature (i maximise the error-free data throughput, (ii do not take into account the content of the data stream, and (iii rely strongly on the use of ARQ. Low-latency applications, such as real-time video transmission, do not permit large numbers of retransmission. In this paper, a novel link adaptation scheme is presented that improves the quality of service (QoS for video transmission. Rather than maximising the error-free throughput, our scheme minimises the video distortion of the received sequence. With the use of simple and local rate distortion measures and end-to-end distortion models at the video encoder, the proposed scheme estimates the received video distortion at the current transmission rate, as well as on the adjacent lower and higher rates. This allows the system to select the link-speed which offers the lowest distortion and to adapt to the channel conditions. Simulation results are presented using the MPEG-4/AVC H.264 video compression standard over IEEE 802.11g. The results show that the proposed system closely follows the optimum theoretic solution.

  12. Beyond teaching language: Towards terminological primacy in learners’ geometric conceptualisation

    Directory of Open Access Journals (Sweden)

    Humphrey U. Atebe

    2010-07-01

    Full Text Available This paper reports on a specific aspect of a broader geometry conceptualisation study that sought to explore and explicate learners’ knowledge of basic geometric terminology in selected Nigerian and South African high schools. It is framed by the notion that students’ acquisition of the correct terminology in school geometry is important for their success in the subject. The original study further aimed to determine the relationship that might exist between a learner’s ability in verbal geometry terminology tasks and his/her ability in visual geometry terminology tasks. A total of 144 learners (72 each from South Africa and Nigeria were selected for the study, using both the stratified and the fish‐bowl sampling techniques. A questionnaire consisting of a sixty‐item multiple‐choice objective test provided the data for the study. An overall percentage mean score of 44,17% obtained in the test indicated that learners in this study had only a limited knowledge of basic geometric terminology. The Nigerian subsample in the study had a weaker understanding of basic geometric terminology than their South African counterparts. Importantly, there were high positive correlations between participants’ ability in verbal geometry terminology tasks and their ability in visual geometry terminology tasks. These results are consistent with those of several earlier studies, and provide a reasonably firm basis for certain recommendations to be made.

  13. Structures and properties of spatially distorted porphyrins

    International Nuclear Information System (INIS)

    Golubchikov, Oleg A; Kuvshinova, Elizaveta M; Pukhovskaya, Svetlana G

    2005-01-01

    The published data on the structures and properties of porphyrins with distorted aromatic macrocycles are generalised and analysed. Data on the crystal structures, spectra and kinetics of formation and dissociation of their coordination derivatives are summarised. It is demonstrated that the distortion of the planar structure of the tetrapyrrole core is one of the most efficient means of controlling spectral, physicochemical and coordination properties of these compounds.

  14. Tuning the dispersion and single/multi-modeness of a hole-assisted fiber by the hole's geometrical parameters

    NARCIS (Netherlands)

    Uranus, H.P.; Hoekstra, Hugo; van Groesen, Embrecht W.C.

    2008-01-01

    Using a vectorial finite element mode solver developed earlier, we studied a hole-assisted multi-ring fiber. We report the role of the hole’s geometrical parameters in tuning the waveguide dispersion and the single/multi-modeness of the particular fiber. By correctly selecting the hole’s size and

  15. Motion illusions in optical art presented for long durations are temporally distorted.

    Science.gov (United States)

    Nather, Francisco Carlos; Mecca, Fernando Figueiredo; Bueno, José Lino Oliveira

    2013-01-01

    Static figurative images implying human body movements observed for shorter and longer durations affect the perception of time. This study examined whether images of static geometric shapes would affect the perception of time. Undergraduate participants observed two Optical Art paintings by Bridget Riley for 9 or 36 s (group G9 and G36, respectively). Paintings implying different intensities of movement (2.0 and 6.0 point stimuli) were randomly presented. The prospective paradigm in the reproduction method was used to record time estimations. Data analysis did not show time distortions in the G9 group. In the G36 group the paintings were differently perceived: that for the 2.0 point one are estimated to be shorter than that for the 6.0 point one. Also for G36, the 2.0 point painting was underestimated in comparison with the actual time of exposure. Motion illusions in static images affected time estimation according to the attention given to the complexity of movement by the observer, probably leading to changes in the storage velocity of internal clock pulses.

  16. Terahertz thickness determination with interferometric vibration correction for industrial applications.

    Science.gov (United States)

    Pfeiffer, Tobias; Weber, Stefan; Klier, Jens; Bachtler, Sebastian; Molter, Daniel; Jonuscheit, Joachim; Von Freymann, Georg

    2018-05-14

    In many industrial fields, like automotive and painting industry, the thickness of thin layers is a crucial parameter for quality control. Hence, the demand for thickness measurement techniques continuously grows. In particular, non-destructive and contact-free terahertz techniques access a wide range of thickness determination applications. However, terahertz time-domain spectroscopy based systems perform the measurement in a sampling manner, requiring fixed distances between measurement head and sample. In harsh industrial environments vibrations of sample and measurement head distort the time-base and decrease measurement accuracy. We present an interferometer-based vibration correction for terahertz time-domain measurements, able to reduce thickness distortion by one order of magnitude for vibrations with frequencies up to 100 Hz and amplitudes up to 100 µm. We further verify the experimental results by numerical calculations and find very good agreement.

  17. Corrections on energy spectrum and scattering for fast neutron radiography at NECTAR facility

    International Nuclear Information System (INIS)

    Liu Shuquan; Thomas, Boucherl; Li Hang; Zou Yubin; Lu Yuanrong; Guo Zhiyu

    2013-01-01

    Distortions caused by the neutron spectrum and scattered neutrons are major problems in fast neutron radiography and should be considered for improving the image quality. This paper puts emphasis on the removal of these image distortions and deviations for fast neutron radiography performed at the NECTAR facility of the research reactor FRM-Ⅱ in Technische Universitaet Mounchen (TUM), Germany. The NECTAR energy spectrum is analyzed and established to modify the influence caused by the neutron spectrum, and the Point Scattered Function (PScF) simulated by the Monte-Carlo program MCNPX is used to evaluate scattering effects from the object and improve image quality. Good analysis results prove the sound effects of the above two corrections. (authors)

  18. Corrections on energy spectrum and scatterings for fast neutron radiography at NECTAR facility

    Science.gov (United States)

    Liu, Shu-Quan; Bücherl, Thomas; Li, Hang; Zou, Yu-Bin; Lu, Yuan-Rong; Guo, Zhi-Yu

    2013-11-01

    Distortions caused by the neutron spectrum and scattered neutrons are major problems in fast neutron radiography and should be considered for improving the image quality. This paper puts emphasis on the removal of these image distortions and deviations for fast neutron radiography performed at the NECTAR facility of the research reactor FRM- II in Technische Universität München (TUM), Germany. The NECTAR energy spectrum is analyzed and established to modify the influence caused by the neutron spectrum, and the Point Scattered Function (PScF) simulated by the Monte-Carlo program MCNPX is used to evaluate scattering effects from the object and improve image quality. Good analysis results prove the sound effects of the above two corrections.

  19. Off-Angle Iris Correction Methods

    Energy Technology Data Exchange (ETDEWEB)

    Santos-Villalobos, Hector J [ORNL; Thompson, Joseph T [ORNL; Karakaya, Mahmut [ORNL; Boehnen, Chris Bensing [ORNL

    2016-01-01

    In many real world iris recognition systems obtaining consistent frontal images is problematic do to inexperienced or uncooperative users, untrained operators, or distracting environments. As a result many collected images are unusable by modern iris matchers. In this chapter we present four methods for correcting off-angle iris images to appear frontal which makes them compatible with existing iris matchers. The methods include an affine correction, a retraced model of the human eye, measured displacements, and a genetic algorithm optimized correction. The affine correction represents a simple way to create an iris image that appears frontal but it does not account for refractive distortions of the cornea. The other method account for refraction. The retraced model simulates the optical properties of the cornea. The other two methods are data driven. The first uses optical flow to measure the displacements of the iris texture when compared to frontal images of the same subject. The second uses a genetic algorithm to learn a mapping that optimizes the Hamming Distance scores between off-angle and frontal images. In this paper we hypothesize that the biological model presented in our earlier work does not adequately account for all variations in eye anatomy and therefore the two data-driven approaches should yield better performance. Results are presented using the commercial VeriEye matcher that show that the genetic algorithm method clearly improves over prior work and makes iris recognition possible up to 50 degrees off-angle.

  20. Effects Of Field Distortions In Ih-apf Linac

    CERN Document Server

    Kapin, Valery; Yamada, S

    2004-01-01

    The project on developing compact medical accelera-tors for the tumor therapy using carbon ions has been started at the National Institute of Radiological Sciences (NIRS). Alternating-phase-focused (APF) linac using an interdigital H-mode (IH) cavity has been proposed for the injector linac. The IH-cavity is doubly ridged circular resonator loaded by the drift-tubes mounted on ridges with supporting stems. The effects of intrinsic and random field distortions in a practical design of the 4-MeV/u 200 MHz IH-APF linac are considered. The intrinsic field distortions in IH-cavity are caused by the asymmetry of the gap field due to presence of the drift-tube supporting stems and pair of ridges. The random field distortions are caused by drift-tube misalignments and non-regular deviations of the voltage distribution from programmed law. The RF fields in IH-cavity have been calculated using Microwave Studio (MWS) code. The effects of field distortions on beam dynamics have been simulated numerically.

  1. Expertise and processing distorted structure in chess.

    Science.gov (United States)

    Bartlett, James C; Boggan, Amy L; Krawczyk, Daniel C

    2013-01-01

    A classic finding in research on human expertise and knowledge is that of enhanced memory for stimuli in a domain of expertise as compared to either stimuli outside that domain, or within-domain stimuli that have been degraded or distorted in some way. However, we do not understand how experts process degradation or distortion of stimuli within the expert domain (e.g., a face with the eyes, nose, and mouth in the wrong positions, or a chessboard with pieces placed randomly). Focusing on the domain of chess, we present new fMRI evidence that when experts view such distorted/within-domain stimuli, they engage an active search for structure-a kind of exploratory chunking-that involves a component of a prefrontal-parietal network linked to consciousness, attention and working memory.

  2. Could unstable relic particles distort the microwave background radiation?

    International Nuclear Information System (INIS)

    Dar, A.; Loeb, A.; Nussinov, S.

    1989-01-01

    Three general classes of possible scenarios for the recently reported distortion of the microwave background radiation (MBR) via decaying relic weakly interacting particles are analyzed. The analysis shows that such particles could not reheat the universe and cause the spectral distortion of the MBR. Gravitational processes such as the early formation of massive black holes may still be plausible energy sources for producing the reported spectral distortion of the MBR at an early cosmological epoch. 24 references

  3. Imaging and assessment of diffusion coefficients by magnetic resonance

    International Nuclear Information System (INIS)

    Tintera, J.; Dezortova, M.; Hajek, M.; Fitzek, C.

    1999-01-01

    The problem of assessment of molecular diffusion by magnetic resonance is highlighted and some typical applications of diffusion imaging in the diagnosis, e.g., of cerebral ischemia, changes in patients with phenylketonuria or multiple sclerosis are discussed. The images were obtained by using diffusion weighted spin echo Echo-Planar Imaging sequence with subsequent correction of the geometrical distortion of the images and calculation of the Apparent Diffusion Coefficient map

  4. UNDERWATER MAPPING USING GLORIA AND MIPS.

    Science.gov (United States)

    Chavez, Pat S.; Anderson, Jeffrey A.; Schoonmaker, James W.

    1987-01-01

    Advances in digital image processing of the (GLORIA) Geological Long-Range Induced Asdic) sidescan-sonar image data have made it technically and economically possible to map large areas of the ocean floor including the Exclusive Economic Zone. Software was written to correct both geometric and radiometric distortions that exist in the original raw GLORIA data. A digital mosaicking technique was developed enabling 2 degree by 2 degree quadrangles to be generated.

  5. Pulse-coupled neural nets: translation, rotation, scale, distortion, and intensity signal invariance for images.

    Science.gov (United States)

    Johnson, J L

    1994-09-10

    The linking-field neural network model of Eckhorn et al. [Neural Comput. 2, 293-307 (1990)] was introduced to explain the experimentally observed synchronous activity among neural assemblies in the cat cortex induced by feature-dependent visual activity. The model produces synchronous bursts of pulses from neurons with similar activity, effectively grouping them by phase and pulse frequency. It gives a basic new function: grouping by similarity. The synchronous bursts are obtained in the limit of strong linking strengths. The linking-field model in the limit of moderate-to-weak linking characterized by few if any multiple bursts is investigated. In this limit dynamic, locally periodic traveling waves exist whose time signal encodes the geometrical structure of a two-dimensional input image. The signal can be made insensitive to translation, scale, rotation, distortion, and intensity. The waves transmit information beyond the physical interconnect distance. The model is implemented in an optical hybrid demonstration system. Results of the simulations and the optical system are presented.

  6. Geometric entanglement in topologically ordered states

    International Nuclear Information System (INIS)

    Orús, Román; Wei, Tzu-Chieh; Buerschaper, Oliver; Nest, Maarten Van den

    2014-01-01

    Here we investigate the connection between topological order and the geometric entanglement, as measured by the logarithm of the overlap between a given state and its closest product state of blocks. We do this for a variety of topologically ordered systems such as the toric code, double semion, colour code and quantum double models. As happens for the entanglement entropy, we find that for sufficiently large block sizes the geometric entanglement is, up to possible sub-leading corrections, the sum of two contributions: a bulk contribution obeying a boundary law times the number of blocks and a contribution quantifying the underlying pattern of long-range entanglement of the topologically ordered state. This topological contribution is also present in the case of single-spin blocks in most cases, and constitutes an alternative characterization of topological order for these quantum states based on a multipartite entanglement measure. In particular, we see that the topological term for the two-dimensional colour code is twice as much as the one for the toric code, in accordance with recent renormalization group arguments (Bombin et al 2012 New J. Phys. 14 073048). Motivated by these results, we also derive a general formalism to obtain upper- and lower-bounds to the geometric entanglement of states with a non-Abelian group symmetry, and which we explicitly use to analyse quantum double models. Furthermore, we also provide an analysis of the robustness of the topological contribution in terms of renormalization and perturbation theory arguments, as well as a numerical estimation for small systems. Some of the results in this paper rely on the ability to disentangle single sites from the quantum state, which is always possible for the systems that we consider. Additionally we relate our results to the behaviour of the relative entropy of entanglement in topologically ordered systems, and discuss a number of numerical approaches based on tensor networks that could be

  7. Carrier Distortion in Hysteretic Self-Oscillating Class-D Audio Power

    DEFF Research Database (Denmark)

    Høyerby, Mikkel Christian Kofod; Andersen, Michael A. E.

    2009-01-01

    An important distortion mechanism in hysteretic self-oscillating (SO) class-D (switch mode) power amplifiers-–carrier distortion-–is analyzed and an optimization method is proposed. This mechanism is an issue in any power amplifier application where a high degree of proportionality between input...... and output is required, such as in audio power amplifiers or xDSL drivers. From an average-mode point of view, carrier distortion is shown to be caused by nonlinear variation of the hysteretic comparator input average voltage with the output average voltage. This easily causes total harmonic distortion...... figures in excess of 0.1–0.2%, inadequate for high-quality audio applications. Carrier distortion is shown to be minimized when the feedback system is designed to provide a triangular carrier (sliding) signal at the input of a hysteretic comparator. The proposed optimization method is experimentally...

  8. Geometric Constructions with the Computer.

    Science.gov (United States)

    Chuan, Jen-chung

    The computer can be used as a tool to represent and communicate geometric knowledge. With the appropriate software, a geometric diagram can be manipulated through a series of animation that offers more than one particular snapshot as shown in a traditional mathematical text. Geometric constructions with the computer enable the learner to see and…

  9. Distorted-wave Born approximation in the case of an optical scattering potential

    International Nuclear Information System (INIS)

    Mytnichenko, Sergey V.

    2005-01-01

    Application of the distorted-wave Born approximation in the conventional form developed for the case of a real scattering potential is shown to cause significant errors in calculating X-ray diffuse scattering from non-ideal crystals, superlattices, multilayers and other objects if energy dissipation (photoabsorption, inelastic scattering, and so on) is not negligible, or in other words, in the case of an optical (complex) scattering potential. We show how a correct expression for the X-ray diffuse-scattering cross-section can be obtained in this case. Generally, the diffuse-scattering cross-section from an optical potential is not T-invariant, i.e. the reciprocity principle is violated. Violations of T-invariance are more evident when the dynamical nature of the diffraction is more critical

  10. Improvement of vector compensation method for vehicle magnetic distortion field

    Energy Technology Data Exchange (ETDEWEB)

    Pang, Hongfeng, E-mail: panghongfeng@126.com; Zhang, Qi; Li, Ji; Luo, Shitu; Chen, Dixiang; Pan, Mengchun; Luo, Feilu

    2014-03-15

    Magnetic distortions such as eddy-current field and low frequency magnetic field have not been considered in vector compensation methods. A new compensation method is proposed to suppress these magnetic distortions and improve compensation performance, in which the magnetic distortions related to measurement vectors and time are considered. The experimental system mainly consists of a three-axis fluxgate magnetometer (DM-050), an underwater vehicle and a proton magnetometer, in which the scalar value of magnetic field is obtained with the proton magnetometer and considered to be the true value. Comparing with traditional compensation methods, experimental results show that the magnetic distortions can be further reduced by two times. After compensation, error intensity and RMS error are reduced from 11684.013 nT and 7794.604 nT to 16.219 nT and 5.907 nT respectively. It suggests an effective way to improve the compensation performance of magnetic distortions. - Highlights: • A new vector compensation method is proposed for vehicle magnetic distortion. • The proposed model not only includes magnetometer error but also considers magnetic distortion. • Compensation parameters are computed directly by solving nonlinear equations. • Compared with traditional methods, the proposed method is not related with rotation angle rate. • Error intensity and RMS error can be reduced to 1/2 of the error with traditional methods.

  11. Improvement of vector compensation method for vehicle magnetic distortion field

    International Nuclear Information System (INIS)

    Pang, Hongfeng; Zhang, Qi; Li, Ji; Luo, Shitu; Chen, Dixiang; Pan, Mengchun; Luo, Feilu

    2014-01-01

    Magnetic distortions such as eddy-current field and low frequency magnetic field have not been considered in vector compensation methods. A new compensation method is proposed to suppress these magnetic distortions and improve compensation performance, in which the magnetic distortions related to measurement vectors and time are considered. The experimental system mainly consists of a three-axis fluxgate magnetometer (DM-050), an underwater vehicle and a proton magnetometer, in which the scalar value of magnetic field is obtained with the proton magnetometer and considered to be the true value. Comparing with traditional compensation methods, experimental results show that the magnetic distortions can be further reduced by two times. After compensation, error intensity and RMS error are reduced from 11684.013 nT and 7794.604 nT to 16.219 nT and 5.907 nT respectively. It suggests an effective way to improve the compensation performance of magnetic distortions. - Highlights: • A new vector compensation method is proposed for vehicle magnetic distortion. • The proposed model not only includes magnetometer error but also considers magnetic distortion. • Compensation parameters are computed directly by solving nonlinear equations. • Compared with traditional methods, the proposed method is not related with rotation angle rate. • Error intensity and RMS error can be reduced to 1/2 of the error with traditional methods

  12. Market distortions and aggregate productivity: Evidence from Chinese energy enterprises

    International Nuclear Information System (INIS)

    Dai, Xiaoyong; Cheng, Liwei

    2016-01-01

    Market distortions can generate resource misallocations across heterogeneous firms and reduce aggregate productivity. This paper measures market distortions and aggregate productivity growth in China's energy sector. We use the wedge between output elasticities and factor shares in revenues to recover a measure of firm-level market distortions. Using data on a large sample of Chinese energy enterprises from 1999 to 2007, our estimations provide strong evidence of the existence of both factor and product market distortions within and across China's various energy industries. The productivity aggregation and decomposition results demonstrate that the estimated aggregate productivity growth (APG) is, on average, 2.595% points per year, of which technological change, resource reallocation, and firm entries and exits account for 1.981, 0.068, and 0.546% points, respectively. The weak contributions of resource reallocation and firm turnover to APG are also found in energy sub-industries, except in the coal industry. Our research suggests that China's energy sector has major potential for productivity gains from resource reallocation through the reduction of market distortions. - Highlights: •We estimate market distortions and productivity growth of China's energy sector. •We use a large sample of Chinese energy enterprises. •There are evidences of the existence of factor and product market distortions. •Aggregate productivity growth is largely driven by firm-level technological change. •China's energy sector can realize productivity gains from resource reallocations.

  13. Convergence of the Distorted Wave Born series

    International Nuclear Information System (INIS)

    MacMillan, D.S.

    1981-01-01

    The aim of this thesis is to begin to understand the idea of reaction mechanisms in nonrelativistic scattering systems. If we have a complete reaction theory of a particular scattering system, then we claim that the theory itself must contain information about important reaction mechanisms in the system. This information can be used to decide what reaction mechanisms should be included in an approximate calculation. To investigate this claim, we studied several solvable models. The primary concept employed in studying our models is the convergence of the multistep series generated by iterating the corresponding scattering integral equation. We known that the eigenvalues of the kernel of the Lippmann-Schwinger equation for potential scattering determine the rate of convergence of the Born series. The Born series will converge only if these eigenvalues all life within the unit circle. We extend these results to a study of the distorted wave Born series for inelastic scattering. The convergence criterion tells us when approximations are valid. We learn how the convergence of the distorted wave series depends upon energy, coupling constants, angular momentum, and angular momentum transfer. In one of our models, we look at several possible distorting potentials to see which one gives the best convergence. We have also applied our results to several actual DWBA or coupled channel calculations in the literature. In addition to the study of models of two-body scattering systems, we have considered the case of rearrangement scattering. We have discussed the formulation of (N greater than or equal to 3)-body distorted wave equations in which the interior dynamics have been redistributed by introducing compact N-body distortion potentials

  14. Forensic image analysis - CCTV distortion and artefacts.

    Science.gov (United States)

    Seckiner, Dilan; Mallett, Xanthé; Roux, Claude; Meuwly, Didier; Maynard, Philip

    2018-04-01

    As a result of the worldwide deployment of surveillance cameras, authorities have gained a powerful tool that captures footage of activities of people in public areas. Surveillance cameras allow continuous monitoring of the area and allow footage to be obtained for later use, if a criminal or other act of interest occurs. Following this, a forensic practitioner, or expert witness can be required to analyse the footage of the Person of Interest. The examination ultimately aims at evaluating the strength of evidence at source and activity levels. In this paper, both source and activity levels are inferred from the trace, obtained in the form of CCTV footage. The source level alludes to features observed within the anatomy and gait of an individual, whilst the activity level relates to activity undertaken by the individual within the footage. The strength of evidence depends on the value of the information recorded, where the activity level is robust, yet source level requires further development. It is therefore suggested that the camera and the associated distortions should be assessed first and foremost and, where possible, quantified, to determine the level of each type of distortion present within the footage. A review of the 'forensic image analysis' review is presented here. It will outline the image distortion types and detail the limitations of differing surveillance camera systems. The aim is to highlight various types of distortion present particularly from surveillance footage, as well as address gaps in current literature in relation to assessment of CCTV distortions in tandem with gait analysis. Future work will consider the anatomical assessment from surveillance footage. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Helical Peierls distortion: Formation of helices of polyketone and polyisocyanide

    Science.gov (United States)

    Cui, Chang-Xing; Kertesz, Miklos

    1990-06-01

    A new type of Peierls-like distortion, the formation of a helix due to the existence of partially filled crossing bands, is reported for polyketone and polyisocyanide. The torsional potential curves, optimized geometries, band structures and phonon dispersion curves are derived. A comparison with the well-known Peierls-distorted all-trans polyacetylene indicates close similarity between the two types of Peierls distortions.

  16. Magnification bias corrections to galaxy-lensing cross-correlations

    International Nuclear Information System (INIS)

    Ziour, Riad; Hui, Lam

    2008-01-01

    Galaxy-galaxy or galaxy-quasar lensing can provide important information on the mass distribution in the Universe. It consists of correlating the lensing signal (either shear or magnification) of a background galaxy/quasar sample with the number density of a foreground galaxy sample. However, the foreground galaxy density is inevitably altered by the magnification bias due to the mass between the foreground and the observer, leading to a correction to the observed galaxy-lensing signal. The aim of this paper is to quantify this correction. The single most important determining factor is the foreground redshift z f : the correction is small if the foreground galaxies are at low redshifts but can become non-negligible for sufficiently high redshifts. For instance, we find that for the multipole l=1000, the correction is above 1%x(5s f -2)/b f for z f > or approx. 0.37, and above 5%x(5s f -2)/b f for z f > or approx. 0.67, where s f is the number count slope of the foreground sample and b f its galaxy bias. These considerations are particularly important for geometrical measures, such as the Jain and Taylor ratio or its generalization by Zhang et al. Assuming (5s f -2)/b f =1, we find that the foreground redshift should be limited to z f < or approx. 0.45 in order to avoid biasing the inferred dark energy equation of state w by more than 5%, and that even for a low foreground redshift (<0.45), the background samples must be well separated from the foreground to avoid incurring a bias of similar magnitude. Lastly, we briefly comment on the possibility of obtaining these geometrical measures without using galaxy shapes, using instead magnification bias itself.

  17. Implicit face prototype learning from geometric information.

    Science.gov (United States)

    Or, Charles C-F; Wilson, Hugh R

    2013-04-19

    There is evidence that humans implicitly learn an average or prototype of previously studied faces, as the unseen face prototype is falsely recognized as having been learned (Solso & McCarthy, 1981). Here we investigated the extent and nature of face prototype formation where observers' memory was tested after they studied synthetic faces defined purely in geometric terms in a multidimensional face space. We found a strong prototype effect: The basic results showed that the unseen prototype averaged from the studied faces was falsely identified as learned at a rate of 86.3%, whereas individual studied faces were identified correctly 66.3% of the time and the distractors were incorrectly identified as having been learned only 32.4% of the time. This prototype learning lasted at least 1 week. Face prototype learning occurred even when the studied faces were further from the unseen prototype than the median variation in the population. Prototype memory formation was evident in addition to memory formation of studied face exemplars as demonstrated in our models. Additional studies showed that the prototype effect can be generalized across viewpoints, and head shape and internal features separately contribute to prototype formation. Thus, implicit face prototype extraction in a multidimensional space is a very general aspect of geometric face learning. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Single-shot imaging with higher-dimensional encoding using magnetic field monitoring and concomitant field correction.

    Science.gov (United States)

    Testud, Frederik; Gallichan, Daniel; Layton, Kelvin J; Barmet, Christoph; Welz, Anna M; Dewdney, Andrew; Cocosco, Chris A; Pruessmann, Klaas P; Hennig, Jürgen; Zaitsev, Maxim

    2015-03-01

    PatLoc (Parallel Imaging Technique using Localized Gradients) accelerates imaging and introduces a resolution variation across the field-of-view. Higher-dimensional encoding employs more spatial encoding magnetic fields (SEMs) than the corresponding image dimensionality requires, e.g. by applying two quadratic and two linear spatial encoding magnetic fields to reconstruct a 2D image. Images acquired with higher-dimensional single-shot trajectories can exhibit strong artifacts and geometric distortions. In this work, the source of these artifacts is analyzed and a reliable correction strategy is derived. A dynamic field camera was built for encoding field calibration. Concomitant fields of linear and nonlinear spatial encoding magnetic fields were analyzed. A combined basis consisting of spherical harmonics and concomitant terms was proposed and used for encoding field calibration and image reconstruction. A good agreement between the analytical solution for the concomitant fields and the magnetic field simulations of the custom-built PatLoc SEM coil was observed. Substantial image quality improvements were obtained using a dynamic field camera for encoding field calibration combined with the proposed combined basis. The importance of trajectory calibration for single-shot higher-dimensional encoding is demonstrated using the combined basis including spherical harmonics and concomitant terms, which treats the concomitant fields as an integral part of the encoding. © 2014 Wiley Periodicals, Inc.

  19. Beyond the Boost: Measuring the Intrinsic Dipole of the Cosmic Microwave Background Using the Spectral Distortions of the Monopole and Quadrupole.

    Science.gov (United States)

    Yasini, Siavash; Pierpaoli, Elena

    2017-12-01

    We present a general framework for the accurate spectral modeling of the low multipoles of the cosmic microwave background (CMB) as observed in a boosted frame. In particular, we demonstrate how spectral measurements of the low multipoles can be used to separate the motion-induced dipole of the CMB from a possible intrinsic dipole component. In a moving frame, the leakage of an intrinsic dipole moment into the CMB monopole and quadrupole induces spectral distortions with distinct frequency functions that, respectively, peak at 337 and 276 GHz. The leakage into the quadrupole moment also induces a geometrical distortion to the spatial morphology of this mode. The combination of these effects can be used to lift the degeneracy between the motion-induced dipole and any intrinsic dipole that the CMB might possess. Assuming the current peculiar velocity measurements, the leakage of an intrinsic dipole with an amplitude of ΔT=30  μK into the monopole and quadrupole moments will be detectable by a PIXIE-like experiment at ∼40  nK (2.5σ) and ∼130  nK (11σ) level at their respective peak frequencies.

  20. SU-F-J-166: Volumetric Spatial Distortions Comparison for 1.5 Tesla Versus 3 Tesla MRI for Gamma Knife Radiosurgery Scans Using Frame Marker Fusion and Co-Registration Modes

    International Nuclear Information System (INIS)

    Neyman, G

    2016-01-01

    Purpose: To compare typical volumetric spatial distortions for 1.5 Tesla versus 3 Tesla MRI Gamma Knife radiosurgery scans in the frame marker fusion and co-registration frame-less modes. Methods: Quasar phantom by Modus Medical Devices Inc. with GRID image distortion software was used for measurements of volumetric distortions. 3D volumetric T1 weighted scans of the phantom were produced on 1.5 T Avanto and 3 T Skyra MRI Siemens scanners. The analysis was done two ways: for scans with localizer markers from the Leksell frame and relatively to the phantom only (simulated co-registration technique). The phantom grid contained a total of 2002 vertices or control points that were used in the assessment of volumetric geometric distortion for all scans. Results: Volumetric mean absolute spatial deviations relatively to the frame localizer markers for 1.5 and 3 Tesla machine were: 1.39 ± 0.15 and 1.63 ± 0.28 mm with max errors of 1.86 and 2.65 mm correspondingly. Mean 2D errors from the Gamma Plan were 0.3 and 1.0 mm. For simulated co-registration technique the volumetric mean absolute spatial deviations relatively to the phantom for 1.5 and 3 Tesla machine were: 0.36 ± 0.08 and 0.62 ± 0.13 mm with max errors of 0.57 and 1.22 mm correspondingly. Conclusion: Volumetric spatial distortions are lower for 1.5 Tesla versus 3 Tesla MRI machines localized with markers on frames and significantly lower for co-registration techniques with no frame localization. The results show the advantage of using co-registration technique for minimizing MRI volumetric spatial distortions which can be especially important for steep dose gradient fields typically used in Gamma Knife radiosurgery. Consultant for Elekta AB

  1. SU-F-J-166: Volumetric Spatial Distortions Comparison for 1.5 Tesla Versus 3 Tesla MRI for Gamma Knife Radiosurgery Scans Using Frame Marker Fusion and Co-Registration Modes

    Energy Technology Data Exchange (ETDEWEB)

    Neyman, G [The Cleveland Clinic Foundation, Cleveland, OH (United States)

    2016-06-15

    Purpose: To compare typical volumetric spatial distortions for 1.5 Tesla versus 3 Tesla MRI Gamma Knife radiosurgery scans in the frame marker fusion and co-registration frame-less modes. Methods: Quasar phantom by Modus Medical Devices Inc. with GRID image distortion software was used for measurements of volumetric distortions. 3D volumetric T1 weighted scans of the phantom were produced on 1.5 T Avanto and 3 T Skyra MRI Siemens scanners. The analysis was done two ways: for scans with localizer markers from the Leksell frame and relatively to the phantom only (simulated co-registration technique). The phantom grid contained a total of 2002 vertices or control points that were used in the assessment of volumetric geometric distortion for all scans. Results: Volumetric mean absolute spatial deviations relatively to the frame localizer markers for 1.5 and 3 Tesla machine were: 1.39 ± 0.15 and 1.63 ± 0.28 mm with max errors of 1.86 and 2.65 mm correspondingly. Mean 2D errors from the Gamma Plan were 0.3 and 1.0 mm. For simulated co-registration technique the volumetric mean absolute spatial deviations relatively to the phantom for 1.5 and 3 Tesla machine were: 0.36 ± 0.08 and 0.62 ± 0.13 mm with max errors of 0.57 and 1.22 mm correspondingly. Conclusion: Volumetric spatial distortions are lower for 1.5 Tesla versus 3 Tesla MRI machines localized with markers on frames and significantly lower for co-registration techniques with no frame localization. The results show the advantage of using co-registration technique for minimizing MRI volumetric spatial distortions which can be especially important for steep dose gradient fields typically used in Gamma Knife radiosurgery. Consultant for Elekta AB.

  2. Shape distortion and dimensional precision in tungsten heavy alloy liquid phase sintering

    International Nuclear Information System (INIS)

    Wuwen Yi; German, R.M.; Lu, P.K.

    2001-01-01

    Microstructure effects on densification and shape distortion in liquid phase sintering of tungsten heavy alloy were investigated. Microstructure parameters such as the solid volume fraction, dihedral angle, initial porosity, and pore size were varied to measure densification and distortion behavior during LPS using W-Ni-Cu alloys. Green compacts were formed using ethylene-bis-stearamide as a pore-forming agent with the amount of polymer controlling the initial porosity. Different initial pore sizes were generated by varying the polymer particle size. Dihedral angle was varied by changing the Ni:Cu ratio in the alloys. Finally, the solid volume fraction was adjusted via the tungsten content. Distortion was quantified using profiles determined with a coordinate measuring machine to calculate a distortion parameter. Sintering results showed that solid volume fraction and dihedral angle are the dominant factors on densification and distortion during liquid phase sintering. Distortion decreases with increasing solid volume fraction and dihedral angle, while initial porosity and pore size have no observable effect on distortion at nearly full densification. Various strategies emerge to improve distortion control in liquid phase sintering. (author)

  3. Application of ray tracing towards a correction for refracting effects in computed tomography with diffracting sources

    International Nuclear Information System (INIS)

    Andersen, A.H.

    1983-01-01

    Ray tracing methods are investigated in forward and inverse processes and applied for image restoration and resolution enhancement in computed tomography with diffracting sources. Within the geometrical optics approximation for a given refractive field, a mathematical model for the forward propagation and inverse reconstruction process is presented. For a finite set of rays in a discrete image representation, an algebraic reconstruction technique is derived which is analogous to the inverse process for a continuum of rays. The geometrical theory of diffraction is invoked to describe ray patterns arising from the introduction of object discontinuity surfaces. We have compared the performance of existing recursive ray tracing techniques for the reconstruction of objects exhibiting discontinuity boundaries. A novel ray tracing and reconstruction technique is presented which enjoys significant computational savings over traditional implementations incorporating tedious ray linking procedures. Simulation studies illustrate the macro-structural distortion and loss of fine resolution when ray refraction is unaccounted for. Restoration and resolution enhancement is achieved with a recursive ray tracing approach. Successful experimental studies with tissue equivalent phantoms are presented. The comparison of simulation and experimental results demonstrated the reasonable assumption of the geometrical optics approximation. Simulation results for larger refractive deviations are encouraging

  4. Distorted representation in visual tourism research

    DEFF Research Database (Denmark)

    Jensen, Martin Trandberg

    2016-01-01

    how photographic materialities, performativities and sensations contribute to new tourism knowledges. While highlighting the potential of distorted representation, the paper posits a cautionary note in regards to the influential role of academic journals in determining the qualities of visual data....... The paper exemplifies distorted representation through three impressionistic tales derived from ethnographic research on the European rail travel phenomenon: interrail.......Tourism research has recently been informed by non-representational theories to highlight the socio-material, embodied and heterogeneous composition of tourist experiences. These advances have contributed to further reflexivity and called for novel ways to animate representations...

  5. Geometrically weighted semiconductor Frisch grid radiation spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    McGregor, D.S. [Dept. of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI 48109-2104 (United States); Rojeski, R.A. [Etec Systems, Inc., 26460 Corporate Ave., Hayward, CA 94545 (United States); He, Z. [Dept. of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI 48109-2104 (United States); Wehe, D.K. [Dept. of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI 48109-2104 (United States); Driver, M. [eV Products, 375 Saxonburg Blvd., Saxonburg, PA 16056 (United States); Blakely, M. [eV Products, 375 Saxonburg Blvd., Saxonburg, PA 16056 (United States)

    1999-02-11

    A new detector geometry is described with relatively high gamma ray energy resolution at room temperature. The device uses the geometric weighting effect, the small pixel effect and the Frisch grid effect to produce high gamma ray energy resolution. The design is simple and easy to construct. The device performs as a gamma ray spectrometer without the need for pulse shape rejection or correction, and it requires only one signal output to any commercially available charge sensitive preamplifier. The device operates very well with conventional NIM electronic systems. Presently, room temperature (23 deg. C) energy resolutions of 2.68% FWHM at 662 keV and 2.45% FWHM at 1.332 MeV have been measured with a 1 cm{sup 3} prism shaped CdZnTe device.

  6. Using Geometrical Properties for Fast Indexation of Gaussian Vector Quantizers

    Directory of Open Access Journals (Sweden)

    Vassilieva EA

    2007-01-01

    Full Text Available Vector quantization is a classical method used in mobile communications. Each sequence of samples of the discretized vocal signal is associated to the closest -dimensional codevector of a given set called codebook. Only the binary indices of these codevectors (the codewords are transmitted over the channel. Since channels are generally noisy, the codewords received are often slightly different from the codewords sent. In order to minimize the distortion of the original signal due to this noisy transmission, codevectors indexed by one-bit different codewords should have a small mutual Euclidean distance. This paper is devoted to this problem of index assignment of binary codewords to the codevectors. When the vector quantizer has a Gaussian structure, we show that a fast index assignment algorithm based on simple geometrical and combinatorial considerations can improve the SNR at the receiver by 5dB with respect to a purely random assignment. We also show that in the Gaussian case this algorithm outperforms the classical combinatorial approach in the field.

  7. Operation of static series compensator under distorted utility conditions

    DEFF Research Database (Denmark)

    Awad, H.; Nelsen, H.; Blaabjerg, Frede

    2005-01-01

    in the case of distorted grid voltage. Furthermore, a selective harmonic compensation strategy is applied to filter out the grid harmonics. The operation of the SSC under distorted utility conditions and voltage dips is discussed. The validity of the proposed controller is verified by experiments, carried out...... on a 10-kV SSC laboratory setup. Experimental results have shown the ability of the SSC to mitigate voltage dips and harmonics. It is also shown that the proposed controller has improved the transient performance of the SSC even under distorted utility conditions....

  8. Characteristic of bio-geometric profile of students’ posture and physical fitness in process of physical education

    Directory of Open Access Journals (Sweden)

    M.V. Dudko

    2015-08-01

    Full Text Available Purpose: to determine specific features of bio-geometric profile of posture and physical fitness of students in process of physical education. Material: 250 students were tested. Video-recording and analysis of bio-geometric profile of human posture were fulfilled. Program Torso was used for this purpose. Results: it was found out that only 15.2% of students had correct posture. The most quantity of posture abnormalities was detected in 36.4% of the tested. In sagittal plane we observed the following types of abnormalities: round back - in 24.4% of students, slouching back - in 24% of students. We found that 63.3% of students with normal posture are in zone of risk. Low backbone flexibility, mobility of hip joints and elasticity of hamstrings was detected on students. Conclusions: students with unsatisfactory bio-geometric profile of posture (scoliosis posture - 43.33%; round back - 23. 33%; slouching back - 22. 73% are in the called pre-morbid state of muscular-skeletal apparatus.

  9. Modeling susceptibility difference artifacts produced by metallic implants in magnetic resonance imaging with point-based thin-plate spline image registration.

    Science.gov (United States)

    Pauchard, Y; Smith, M; Mintchev, M

    2004-01-01

    Magnetic resonance imaging (MRI) suffers from geometric distortions arising from various sources. One such source are the non-linearities associated with the presence of metallic implants, which can profoundly distort the obtained images. These non-linearities result in pixel shifts and intensity changes in the vicinity of the implant, often precluding any meaningful assessment of the entire image. This paper presents a method for correcting these distortions based on non-rigid image registration techniques. Two images from a modelled three-dimensional (3D) grid phantom were subjected to point-based thin-plate spline registration. The reference image (without distortions) was obtained from a grid model including a spherical implant, and the corresponding test image containing the distortions was obtained using previously reported technique for spatial modelling of magnetic susceptibility artifacts. After identifying the nonrecoverable area in the distorted image, the calculated spline model was able to quantitatively account for the distortions, thus facilitating their compensation. Upon the completion of the compensation procedure, the non-recoverable area was removed from the reference image and the latter was compared to the compensated image. Quantitative assessment of the goodness of the proposed compensation technique is presented.

  10. Transmuted Complementary Weibull Geometric Distribution

    Directory of Open Access Journals (Sweden)

    Ahmed Z. A…fify

    2014-12-01

    Full Text Available This paper provides a new generalization of the complementary Weibull geometric distribution that introduced by Tojeiro et al. (2014, using the quadratic rank transmutation map studied by Shaw and Buckley (2007. The new distribution is referred to as transmuted complementary Weibull geometric distribution (TCWGD. The TCWG distribution includes as special cases the complementary Weibull geometric distribution (CWGD, complementary exponential geometric distribution(CEGD,Weibull distribution (WD and exponential distribution (ED. Various structural properties of the new distribution including moments, quantiles, moment generating function and RØnyi entropy of the subject distribution are derived. We proposed the method of maximum likelihood for estimating the model parameters and obtain the observed information matrix. A real data set are used to compare the ‡exibility of the transmuted version versus the complementary Weibull geometric distribution.

  11. Distorted Risk Measures with Application to Military Capability Shortfalls

    Science.gov (United States)

    2005-12-15

    effects of different distortions and to make basic recommendations regarding the appropriateness of certain distortion functions and parameters using...and increased limits ratemaking by proportional hazards transforms. Insurance: Mathematics and Economics, 17: 43-54. [9] Wang, S. (1996a). Premium

  12. Audible Aliasing Distortion in Digital Audio Synthesis

    Directory of Open Access Journals (Sweden)

    J. Schimmel

    2012-04-01

    Full Text Available This paper deals with aliasing distortion in digital audio signal synthesis of classic periodic waveforms with infinite Fourier series, for electronic musical instruments. When these waveforms are generated in the digital domain then the aliasing appears due to its unlimited bandwidth. There are several techniques for the synthesis of these signals that have been designed to avoid or reduce the aliasing distortion. However, these techniques have high computing demands. One can say that today's computers have enough computing power to use these methods. However, we have to realize that today’s computer-aided music production requires tens of multi-timbre voices generated simultaneously by software synthesizers and the most of the computing power must be reserved for hard-disc recording subsystem and real-time audio processing of many audio channels with a lot of audio effects. Trivially generated classic analog synthesizer waveforms are therefore still effective for sound synthesis. We cannot avoid the aliasing distortion but spectral components produced by the aliasing can be masked with harmonic components and thus made inaudible if sufficient oversampling ratio is used. This paper deals with the assessment of audible aliasing distortion with the help of a psychoacoustic model of simultaneous masking and compares the computing demands of trivial generation using oversampling with those of other methods.

  13. Geometric phases in discrete dynamical systems

    Energy Technology Data Exchange (ETDEWEB)

    Cartwright, Julyan H.E., E-mail: julyan.cartwright@csic.es [Instituto Andaluz de Ciencias de la Tierra, CSIC–Universidad de Granada, E-18100 Armilla, Granada (Spain); Instituto Carlos I de Física Teórica y Computacional, Universidad de Granada, E-18071 Granada (Spain); Piro, Nicolas, E-mail: nicolas.piro@epfl.ch [École Polytechnique Fédérale de Lausanne (EPFL), 1015 Lausanne (Switzerland); Piro, Oreste, E-mail: piro@imedea.uib-csic.es [Departamento de Física, Universitat de les Illes Balears, E-07122 Palma de Mallorca (Spain); Tuval, Idan, E-mail: ituval@imedea.uib-csic.es [Mediterranean Institute for Advanced Studies, CSIC–Universitat de les Illes Balears, E-07190 Mallorca (Spain)

    2016-10-14

    In order to study the behaviour of discrete dynamical systems under adiabatic cyclic variations of their parameters, we consider discrete versions of adiabatically-rotated rotators. Parallelling the studies in continuous systems, we generalize the concept of geometric phase to discrete dynamics and investigate its presence in these rotators. For the rotated sine circle map, we demonstrate an analytical relationship between the geometric phase and the rotation number of the system. For the discrete version of the rotated rotator considered by Berry, the rotated standard map, we further explore this connection as well as the role of the geometric phase at the onset of chaos. Further into the chaotic regime, we show that the geometric phase is also related to the diffusive behaviour of the dynamical variables and the Lyapunov exponent. - Highlights: • We extend the concept of geometric phase to maps. • For the rotated sine circle map, we demonstrate an analytical relationship between the geometric phase and the rotation number. • For the rotated standard map, we explore the role of the geometric phase at the onset of chaos. • We show that the geometric phase is related to the diffusive behaviour of the dynamical variables and the Lyapunov exponent.

  14. Evaluation of Probe-Induced Flow Distortion of Campbell CSAT3 Sonic Anemometers by Numerical Simulation

    Science.gov (United States)

    Huq, Sadiq; De Roo, Frederik; Foken, Thomas; Mauder, Matthias

    2017-10-01

    The Campbell CSAT3 sonic anemometer is one of the most popular instruments for turbulence measurements in basic micrometeorological research and ecological applications. While measurement uncertainty has been characterized by field experiments and wind-tunnel studies in the past, there are conflicting estimates, which motivated us to conduct a numerical experiment using large-eddy simulation to evaluate the probe-induced flow distortion of the CSAT3 anemometer under controlled conditions, and with exact knowledge of the undisturbed flow. As opposed to wind-tunnel studies, we imposed oscillations in both the vertical and horizontal velocity components at the distinct frequencies and amplitudes found in typical turbulence spectra in the surface layer. The resulting flow-distortion errors for the standard deviations of the vertical velocity component range from 3 to 7%, and from 1 to 3% for the horizontal velocity component, depending on the azimuth angle. The magnitude of these errors is almost independent of the frequency of wind speed fluctuations, provided the amplitude is typical for surface-layer turbulence. A comparison of the corrections for transducer shadowing proposed by both Kaimal et al. (Proc Dyn Flow Conf, 551-565, 1978) and Horst et al. (Boundary-Layer Meteorol 155:371-395, 2015) show that both methods compensate for a larger part of the observed error, but do not sufficiently account for the azimuth dependency. Further numerical simulations could be conducted in the future to characterize the flow distortion induced by other existing types of sonic anemometers for the purposes of optimizing their geometry.

  15. A Simple and Efficient Methodology To Improve Geometric Accuracy in Gamma Knife Radiation Surgery: Implementation in Multiple Brain Metastases

    Energy Technology Data Exchange (ETDEWEB)

    Karaiskos, Pantelis, E-mail: pkaraisk@med.uoa.gr [Medical Physics Laboratory, Medical School, University of Athens (Greece); Gamma Knife Department, Hygeia Hospital, Athens (Greece); Moutsatsos, Argyris; Pappas, Eleftherios; Georgiou, Evangelos [Medical Physics Laboratory, Medical School, University of Athens (Greece); Roussakis, Arkadios [CT and MRI Department, Hygeia Hospital, Athens (Greece); Torrens, Michael [Gamma Knife Department, Hygeia Hospital, Athens (Greece); Seimenis, Ioannis [Medical Physics Laboratory, Medical School, Democritus University of Thrace, Alexandroupolis (Greece)

    2014-12-01

    Purpose: To propose, verify, and implement a simple and efficient methodology for the improvement of total geometric accuracy in multiple brain metastases gamma knife (GK) radiation surgery. Methods and Materials: The proposed methodology exploits the directional dependence of magnetic resonance imaging (MRI)-related spatial distortions stemming from background field inhomogeneities, also known as sequence-dependent distortions, with respect to the read-gradient polarity during MRI acquisition. First, an extra MRI pulse sequence is acquired with the same imaging parameters as those used for routine patient imaging, aside from a reversal in the read-gradient polarity. Then, “average” image data are compounded from data acquired from the 2 MRI sequences and are used for treatment planning purposes. The method was applied and verified in a polymer gel phantom irradiated with multiple shots in an extended region of the GK stereotactic space. Its clinical impact in dose delivery accuracy was assessed in 15 patients with a total of 96 relatively small (<2 cm) metastases treated with GK radiation surgery. Results: Phantom study results showed that use of average MR images eliminates the effect of sequence-dependent distortions, leading to a total spatial uncertainty of less than 0.3 mm, attributed mainly to gradient nonlinearities. In brain metastases patients, non-eliminated sequence-dependent distortions lead to target localization uncertainties of up to 1.3 mm (mean: 0.51 ± 0.37 mm) with respect to the corresponding target locations in the “average” MRI series. Due to these uncertainties, a considerable underdosage (5%-32% of the prescription dose) was found in 33% of the studied targets. Conclusions: The proposed methodology is simple and straightforward in its implementation. Regarding multiple brain metastases applications, the suggested approach may substantially improve total GK dose delivery accuracy in smaller, outlying targets.

  16. Band co-registration modeling of LAPAN-A3/IPB multispectral imager based on satellite attitude

    Science.gov (United States)

    Hakim, P. R.; Syafrudin, A. H.; Utama, S.; Jayani, A. P. S.

    2018-05-01

    One of significant geometric distortion on images of LAPAN-A3/IPB multispectral imager is co-registration error between each color channel detector. Band co-registration distortion usually can be corrected by using several approaches, which are manual method, image matching algorithm, or sensor modeling and calibration approach. This paper develops another approach to minimize band co-registration distortion on LAPAN-A3/IPB multispectral image by using supervised modeling of image matching with respect to satellite attitude. Modeling results show that band co-registration error in across-track axis is strongly influenced by yaw angle, while error in along-track axis is fairly influenced by both pitch and roll angle. Accuracy of the models obtained is pretty good, which lies between 1-3 pixels error for each axis of each pair of band co-registration. This mean that the model can be used to correct the distorted images without the need of slower image matching algorithm, nor the laborious effort needed in manual approach and sensor calibration. Since the calculation can be executed in order of seconds, this approach can be used in real time quick-look image processing in ground station or even in satellite on-board image processing.

  17. The geometric accuracy of frameless stereotactic radiosurgery using a 6D robotic couch system

    Energy Technology Data Exchange (ETDEWEB)

    Takakura, T; Nakata, M; Yano, S; Fujimoto, T [Division of Clinical Radiology Service, Kyoto University Hospital, Kyoto (Japan); Mizowaki, T; Miyabe, Y; Nakamura, M; Hiraoka, M [Department of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicine, Kyoto (Japan)], E-mail: toru1@kuhp.kyoto-u.ac.jp

    2010-01-07

    The aim of this paper is to assess the overall geometric accuracy of the Novalis system using the Robotic Tilt Module in terms of the uncertainty in frameless stereotactic radiotherapy. We analyzed the following three metrics: (1) the correction accuracy of the robotic couch, (2) the uncertainty of the isocenter position with gantry and couch rotation, and (3) the shift in position between the isocenter and central point detected with the ExacTrac x-ray system. Based on the concept of uncertainty, the overall accuracy was calculated from these values. The accuracy in positional correction with the robotic couch was 0.07 {+-} 0.22 mm, the positional shift of the isocenter associated with gantry rotation was 0.35 mm, the positional shift of the isocenter associated with couch rotation was 0.38 mm and the difference in position between the isocenter and the ExacTrac x-ray system was 0.30 mm. The accuracy of intracranial stereotactic radiosurgery with the Novalis system in our clinic was 0.31 {+-} 0.77 mm. The overall geometric accuracy based on the concept of uncertainty was 0.31 {+-} 0.77 mm, which is within the tolerance given in the American Association of Physicists in Medicine report no. 54.

  18. The geometric accuracy of frameless stereotactic radiosurgery using a 6D robotic couch system

    International Nuclear Information System (INIS)

    Takakura, T; Nakata, M; Yano, S; Fujimoto, T; Mizowaki, T; Miyabe, Y; Nakamura, M; Hiraoka, M

    2010-01-01

    The aim of this paper is to assess the overall geometric accuracy of the Novalis system using the Robotic Tilt Module in terms of the uncertainty in frameless stereotactic radiotherapy. We analyzed the following three metrics: (1) the correction accuracy of the robotic couch, (2) the uncertainty of the isocenter position with gantry and couch rotation, and (3) the shift in position between the isocenter and central point detected with the ExacTrac x-ray system. Based on the concept of uncertainty, the overall accuracy was calculated from these values. The accuracy in positional correction with the robotic couch was 0.07 ± 0.22 mm, the positional shift of the isocenter associated with gantry rotation was 0.35 mm, the positional shift of the isocenter associated with couch rotation was 0.38 mm and the difference in position between the isocenter and the ExacTrac x-ray system was 0.30 mm. The accuracy of intracranial stereotactic radiosurgery with the Novalis system in our clinic was 0.31 ± 0.77 mm. The overall geometric accuracy based on the concept of uncertainty was 0.31 ± 0.77 mm, which is within the tolerance given in the American Association of Physicists in Medicine report no. 54.

  19. Motivational Distortion on 16 PF Primaries by Male Felons.

    Science.gov (United States)

    Wallbrown, Fred H.; And Others

    1989-01-01

    Investigated motivational distortion using the 16 Personality Factor Questionnaire (16 PF) for male (n=331) criminal offenders. Results indicated that ego-strength, free-floating anxiety, ability to bind anxiety, boldness, dominance, emotional sensitivity and suspiciousness contributed most to the motivational distortion scale predictions.…

  20. Geometrical properties of rough metallic surfaces and their implication in electromagnetic problems

    International Nuclear Information System (INIS)

    Hernandez, A.; Chicon, R.; Ortuno, M.; Abellan, J.

    1987-01-01

    We analyze the geometrical properties and their implications in the effective surface resistance and wall losses of rough metallic surfaces. The power spectrum and the autocorrelation function are calculated for a simple model that adequately represent the rough surface. The roughness parameters are obtained through average values of the roughness and its derivative. We calculate the density profile, directly related to the depth-dependent effective conductivity. The data from the profilometer are corrected to take into account the finite size of the tip. (author)

  1. Semi-empirical γ-ray peak efficiency determination including self-absorption correction based on numerical integration

    International Nuclear Information System (INIS)

    Noguchi, M.; Takeda, K.; Higuchi, H.

    1981-01-01

    A method of γ-ray efficiency determination for extended (plane or bulk) samples based on numerical integration of point source efficiency is studied. The proposed method is widely applicable to samples of various shapes and materials. The geometrical factor in the peak efficiency can easily be corrected for by simply changing the integration region, and γ-ray self-absorption is also corrected by the absorption coefficients for the sample matrix. (author)

  2. Mode distortion measurements on the Jefferson lab IR FEL

    CERN Document Server

    Benson, S V; Shinn, M

    2002-01-01

    We have previously reported on the analytical calculations of mirror distortion in a high-power FEL with a near-concentric cavity. This analysis allowed us to estimate the power level at which the FEL interaction would be affected, though no exact theory of FEL power vs. distortion exists at this point. Recently we have directly measured the mode size and beam quality as a function of power using a resonator with a center wavelength of 5 mu m. The resonator mirrors were calcium fluoride. This particular material exhibits a large amount of distortion for a given power but, due to the negative slope of refractive index vs. temperature, adds almost no optical phase distortion on the laser output. The mode in the cavity can thus be directly calculated from the measurements at the resonator output. The presence of angular jitter produced raw measurements inconsistent with cold cavity expectations. Removing the effects of the angular jitter, we derive results in agreement with cold cavity measurements. The result i...

  3. Factors associated with body image distortion in Korean adolescents

    Directory of Open Access Journals (Sweden)

    Hyun MY

    2014-05-01

    Full Text Available Mi-Yeul Hyun,1 Young-Eun Jung,2 Moon-Doo Kim,2 Young-Sook Kwak,2 Sung-Chul Hong,3 Won-Myong Bahk,4 Bo-Hyun Yoon,5 Hye Won Yoon,6 Bora Yoo61College of Nursing, Jeju National University, Jeju, Korea; 2Department of Psychiatry, School of Medicine, Jeju National University, Jeju, Korea; 3Department of Preventive Medicine, School of Medicine, Jeju National University, Jeju, Korea; 4Department of Psychiatry, Yeouido St Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea; 5Department of Psychiatry, Naju National Hospital, Naju, Korea; 6School of Medicine, Jeju National University, Jeju, KoreaPurpose: Body image incorporates cognitive and affective components as well as behaviors related to own body perception. This study evaluated the occurrence of body image distortion and its correlates in Korean adolescents.Methods: In a school-based cross-sectional survey, a total of 2,117 adolescents were recruited. They filled out self-completing questionnaires on body image distortion, eating attitudes, and behaviors (Eating Attitude Test-26 and related factors.Results: Body image distortions were found in 51.8 percent of adolescents. Univariate analyses showed that boys and older adolescents had higher rates of body image distortion. In the multivariate analyses, body image distortion was associated with high risk for eating disorders (odds ratio [OR] =1.69; 95% confidence interval [CI] 1.11–2.58; P=0.015 and being over weight (OR =33.27; 95% CI 15.51–71.35; P<0.001 or obese (OR =9.37; 95% CI 5.06–17.34; P<0.001.Conclusion: These results suggest that body image distortion is relatively common in Korean adolescents, which has implications for adolescents at risk of developing eating disorders.Keywords: body image distortion, high risk for eating disorders, Korean adolescent

  4. Pump-induced optical distortions in disk amplifier modules: holographic and interferometric measurements

    International Nuclear Information System (INIS)

    Linford, G.J.; Chau, H.H.; Glaze, J.A.; Layne, C.B.; Rainer, F.

    1975-01-01

    Interferometric measurements have been made of the optical distortions induced in laser disk amplifiers during the flashlamp pumping pulse. Both conventional interferometric methods and the techniques of double exposure holographic interferometry were used to identify four major sources of pump-induced optical distortions: subsonic intrusion of hot gas (traced to leakage of atmospheric oxygen into the amplifier), microexplosions of dust particles, thermally induced optical distortions in the glass disks, and gaseous optical distortion effects caused by turbulent flow of the purging nitrogen gas supply used within the laser amplifier head. Methods for reducing or eliminating the effects of each of these optical distortions are described

  5. Distortion of gravitational-wave packets due to their self-gravity

    International Nuclear Information System (INIS)

    Kocsis, Bence; Loeb, Abraham

    2007-01-01

    When a source emits a gravity-wave (GW) pulse over a short period of time, the leading edge of the GW signal is redshifted more than the inner boundary of the pulse. The GW pulse is distorted by the gravitational effect of the self-energy residing in between these shells. We illustrate this distortion for GW pulses from the final plunge of black hole binaries, leading to the evolution of the GW profile as a function of the radial distance from the source. The distortion depends on the total GW energy released ε and the duration of the emission τ, scaled by the total binary mass M. The effect should be relevant in finite box simulations where the waveforms are extracted within a radius of 2 M. For characteristic emission parameters at the final plunge between binary black holes of arbitrary spins, this effect could distort the simulated GW templates for LIGO and LISA by a fraction of 10 -3 . Accounting for the wave distortion would significantly decrease the waveform extraction errors in numerical simulations

  6. Overview of Akatsuki data products: definition of data levels, method and accuracy of geometric correction

    Science.gov (United States)

    Ogohara, Kazunori; Takagi, Masahiro; Murakami, Shin-ya; Horinouchi, Takeshi; Yamada, Manabu; Kouyama, Toru; Hashimoto, George L.; Imamura, Takeshi; Yamamoto, Yukio; Kashimura, Hiroki; Hirata, Naru; Sato, Naoki; Yamazaki, Atsushi; Satoh, Takehiko; Iwagami, Naomoto; Taguchi, Makoto; Watanabe, Shigeto; Sato, Takao M.; Ohtsuki, Shoko; Fukuhara, Tetsuya; Futaguchi, Masahiko; Sakanoi, Takeshi; Kameda, Shingo; Sugiyama, Ko-ichiro; Ando, Hiroki; Lee, Yeon Joo; Nakamura, Masato; Suzuki, Makoto; Hirose, Chikako; Ishii, Nobuaki; Abe, Takumi

    2017-12-01

    We provide an overview of data products from observations by the Japanese Venus Climate Orbiter, Akatsuki, and describe the definition and content of each data-processing level. Levels 1 and 2 consist of non-calibrated and calibrated radiance (or brightness temperature), respectively, as well as geometry information (e.g., illumination angles). Level 3 data are global-grid data in the regular longitude-latitude coordinate system, produced from the contents of Level 2. Non-negligible errors in navigational data and instrumental alignment can result in serious errors in the geometry calculations. Such errors cause mismapping of the data and lead to inconsistencies between radiances and illumination angles, along with errors in cloud-motion vectors. Thus, we carefully correct the boresight pointing of each camera by fitting an ellipse to the observed Venusian limb to provide improved longitude-latitude maps for Level 3 products, if possible. The accuracy of the pointing correction is also estimated statistically by simulating observed limb distributions. The results show that our algorithm successfully corrects instrumental pointing and will enable a variety of studies on the Venusian atmosphere using Akatsuki data.[Figure not available: see fulltext.

  7. Correction of beam-beam effects in luminosity measurement in the forward region at CLIC

    CERN Document Server

    Lukic, Strahinja

    2013-01-01

    Procedures for correcting the beam-beam effects in luminosity measurement at CLIC at 3 TeV CM energy are described and tested using Monte Carlo simulations: - Correction of the angular counting loss due to the combined Beamstrahlung and initial-state radiation (ISR) effects, based on the reconstructed velocity of the collision frame of the Bhabha scattering. - Deconvolution of the luminosity spectrum distortion due to the ISR emission. - Correction of the counting bias due to the finite calorimeter energy resolution. All procedures were tested by simulation. Bhabha events were generated using BHLUMI, and used in Guinea-PIG to simulate the outgoing momenta of Bhabha particles in the bunch collisions at CLIC. Residual uncertainties after correction are listed in a table in the conclusions. The beam-beam related systematic counting uncertainty in the luminosity peak can be reduced to the order of permille.

  8. Correction of beam-beam effects in luminosity measurement in the forward region at CLIC

    CERN Document Server

    Lukic, Strahinja

    2013-01-01

    Procedures for correcting the beam-beam effects in luminosity measurement at CLIC at 3 TeV CM energy are described and tested using Monte Carlo simulations: -> Correction of the angular counting loss due to the combined Beamstrahlung and initial-state radiation (ISR) effects, based on the reconstructed velocity of the collision frame of the Bhabha scattering. -> Deconvolution of the luminosity spectrum distortion due to the ISR emission. -> Correction of the counting bias due to the finite calorimeter energy resolution. All procedures were tested by simulation. Bhabha events were generated using BHLUMI, and used in Guinea-PIG to simulate the outgoing momenta of Bhabha particles in the bunch collisions at CLIC. Residual uncertainties after correction are listed in a table in the conclusions. The beam-beam related systematic counting uncertainty in the luminosity peak can be reduced to the order of permille.

  9. Influence of Digital Camera Errors on the Photogrammetric Image Processing

    Science.gov (United States)

    Sužiedelytė-Visockienė, Jūratė; Bručas, Domantas

    2009-01-01

    The paper deals with the calibration of digital camera Canon EOS 350D, often used for the photogrammetric 3D digitalisation and measurements of industrial and construction site objects. During the calibration data on the optical and electronic parameters, influencing the distortion of images, such as correction of the principal point, focal length of the objective, radial symmetrical and non-symmetrical distortions were obtained. The calibration was performed by means of the Tcc software implementing the polynomial of Chebichev and using a special test-field with the marks, coordinates of which are precisely known. The main task of the research - to determine how parameters of the camera calibration influence the processing of images, i. e. the creation of geometric model, the results of triangulation calculations and stereo-digitalisation. Two photogrammetric projects were created for this task. In first project the non-corrected and in the second the corrected ones, considering the optical errors of the camera obtained during the calibration, images were used. The results of analysis of the images processing is shown in the images and tables. The conclusions are given.

  10. Interatomic potentials and lattice distortions in PdDsub(0.8)

    International Nuclear Information System (INIS)

    McKergow, M.W.; Gilberd, P.W.; Picton, D.J.; Ross, D.K.

    1985-01-01

    Dispersion curve measurements on β-phase PdDsub(0.82) have been carried out by neutron scattering, for both the deuteron random structure and the low-temperature ''Ni 4 Mo'' ordered structure. Fits to the data have been obtained using a 10-parameter Born-Von Karman model constrained to yield spherically symmetric potentials for stoichiometric PdD, and corrected for non-stoichiometry by a Mean Field approximation. The Pd-D interaction is found to be attractive, consistent with a stable octahedral site. These potentials have been used to calculate lattice distortion effects in ordered PdDsub(x) using the program DEVIL. This code allows the atoms in a model crystallite to relax so as to minimise potential energy. The Ni 4 Mo structure is found to permit deuteron relaxation, leading to a comparatively large relaxation energy, whilst the competing DO 22 structure does not. Residual stresses due to the ordering process are also calculated. (orig.) [de

  11. Cognitive distortions among older adult gamblers in an Asian context.

    Directory of Open Access Journals (Sweden)

    Mythily Subramaniam

    Full Text Available The study aims to describe the construct of cognitive distortions based on the narratives of older adult gamblers (aged 60 years and above in Singapore.Singapore residents (citizens or permanent residents aged 60 years and above, who were current or past regular gamblers were included in the study. Participants were recruited using a combination of venue based approach, referrals from service providers as well as by snowball sampling. In all, 25 in-depth interviews were conducted with older adult gamblers. The six-step thematic network analysis methodology was adopted for data analysis.The mean age of the participants was 66.2 years. The majority were male (n = 18, of Chinese ethnicity (n = 16, with a mean age of gambling initiation at 24.5 years. Among older adult gamblers, cognitive distortions emerged as a significant global theme comprising three organizing themes-illusion of control, probability control and interpretive control. The organizing themes comprised nine basic themes: perception of gambling as a skill, near miss, concept of luck, superstitious beliefs, entrapment, gambler's fallacy, chasing wins, chasing losses, and beliefs that wins are more than losses.Cognitive distortions were endorsed by all gamblers in the current study and were shown to play a role in both maintaining and escalating the gambling behaviour. While the surface characteristics of the distortions had a culture-specific appearance, the deeper characteristics of the distortions may in fact be more universal than previously thought. Future research must include longitudinal studies to understand causal relationships between cognitive distortions and gambling as well as the role of culture-specific distortions both in the maintenance and treatment of the disorder.

  12. Lidar inelastic multiple-scattering parameters of cirrus particle ensembles determined with geometrical-optics crystal phase functions.

    Science.gov (United States)

    Reichardt, J; Hess, M; Macke, A

    2000-04-20

    Multiple-scattering correction factors for cirrus particle extinction coefficients measured with Raman and high spectral resolution lidars are calculated with a radiative-transfer model. Cirrus particle-ensemble phase functions are computed from single-crystal phase functions derived in a geometrical-optics approximation. Seven crystal types are considered. In cirrus clouds with height-independent particle extinction coefficients the general pattern of the multiple-scattering parameters has a steep onset at cloud base with values of 0.5-0.7 followed by a gradual and monotonic decrease to 0.1-0.2 at cloud top. The larger the scattering particles are, the more gradual is the rate of decrease. Multiple-scattering parameters of complex crystals and of imperfect hexagonal columns and plates can be well approximated by those of projected-area equivalent ice spheres, whereas perfect hexagonal crystals show values as much as 70% higher than those of spheres. The dependencies of the multiple-scattering parameters on cirrus particle spectrum, base height, and geometric depth and on the lidar parameters laser wavelength and receiver field of view, are discussed, and a set of multiple-scattering parameter profiles for the correction of extinction measurements in homogeneous cirrus is provided.

  13. Time series data correction for the Chang'E-1 gamma-ray spectrometer

    Institute of Scientific and Technical Information of China (English)

    Li-Yan Zhang; Yong-Liao Zou; Jian-Zhong Liu; Jian-Jun Liu; Ji Shen; Ling-Li Mu; Xin Ren; Wei-Bin Wen; Chun-Lai Li

    2011-01-01

    The main goal of the gamma-ray spectrometer (GRS) onboard Chang'E-l (CE-1) is to acquire global maps of elemental abundances and their distributions on the moon, since such maps will significantly improve our understanding of lunar formation and evolution. To derive the elemental maps and enable research on lunar formation and evolution, raw data that are received directly from the spacecraft must be converted into time series corrected gamma-ray spectra. The data correction procedures for the CE-1 GRS time series data are thoroughly described. The processing procedures to create the time series gamma-ray spectra described here include channel processing, optimal data selection, energy calibration, gain correction, dead time correction, geometric correction, orbit altitude normalization, eliminating unusable data and galactic cosmic ray correction. Finally, descriptions are also given on data measurement uncertainties, which will help the interested scientists to understand and estimate various uncertainties associated with the above data processing.

  14. Time series data correction for the Chang'E-1 gamma-ray spectrometer

    International Nuclear Information System (INIS)

    Zhang Liyan; Zou Yongliao; Liu Jianzhong; Liu Jianjun; Shen Ji; Mu Lingli; Ren Xin; Wen Weibin; Li Chunlai

    2011-01-01

    The main goal of the gamma-ray spectrometer (GRS) onboard Chang'E-1 (CE-1) is to acquire global maps of elemental abundances and their distributions on the moon, since such maps will significantly improve our understanding of lunar formation and evolution. To derive the elemental maps and enable research on lunar formation and evolution, raw data that are received directly from the spacecraft must be converted into time series corrected gamma-ray spectra. The data correction procedures for the CE-1 GRS time series data are thoroughly described. The processing procedures to create the time series gamma-ray spectra described here include channel processing, optimal data selection, energy calibration, gain correction, dead time correction, geometric correction, orbit altitude normalization, eliminating unusable data and galactic cosmic ray correction. Finally, descriptions are also given on data measurement uncertainties, which will help the interested scientists to understand and estimate various uncertainties associated with the above data processing. (research papers)

  15. Perceptual distortion analysis of color image VQ-based coding

    Science.gov (United States)

    Charrier, Christophe; Knoblauch, Kenneth; Cherifi, Hocine

    1997-04-01

    It is generally accepted that a RGB color image can be easily encoded by using a gray-scale compression technique on each of the three color planes. Such an approach, however, fails to take into account correlations existing between color planes and perceptual factors. We evaluated several linear and non-linear color spaces, some introduced by the CIE, compressed with the vector quantization technique for minimum perceptual distortion. To study these distortions, we measured contrast and luminance of the video framebuffer, to precisely control color. We then obtained psychophysical judgements to measure how well these methods work to minimize perceptual distortion in a variety of color space.

  16. Distortion of Probability and Outcome Information in Risky Decisions

    Science.gov (United States)

    DeKay, Michael L.; Patino-Echeverri, Dalia; Fischbeck, Paul S.

    2009-01-01

    Substantial evidence indicates that information is distorted during decision making, but very few studies have assessed the distortion of probability and outcome information in risky decisions. In two studies involving six binary decisions (e.g., banning blood donations from people who have visited England, because of "mad cow disease"),…

  17. Audiovisual Cues and Perceptual Learning of Spectrally Distorted Speech

    Science.gov (United States)

    Pilling, Michael; Thomas, Sharon

    2011-01-01

    Two experiments investigate the effectiveness of audiovisual (AV) speech cues (cues derived from both seeing and hearing a talker speak) in facilitating perceptual learning of spectrally distorted speech. Speech was distorted through an eight channel noise-vocoder which shifted the spectral envelope of the speech signal to simulate the properties…

  18. Geometrical model of multiple production

    International Nuclear Information System (INIS)

    Chikovani, Z.E.; Jenkovszky, L.L.; Kvaratshelia, T.M.; Struminskij, B.V.

    1988-01-01

    The relation between geometrical and KNO-scaling and their violation is studied in a geometrical model of multiple production of hadrons. Predictions concerning the behaviour of correlation coefficients at future accelerators are given

  19. Distorted eikonal cross sections: A time-dependent view

    International Nuclear Information System (INIS)

    Turner, R.E.

    1982-01-01

    For Hamiltonians with two potentials, differential cross sections are written as time-correlation functions of reference and distorted transition operators. Distorted eikonal differential cross sections are defined in terms of straight-line and reference classical trajectories. Both elastic and inelastic results are obtained. Expressions for the inelastic cross sections are presented in terms of time-ordered cosine and sine memory functions through the use of the Zwanzig-Feshbach projection-operator method

  20. Pragmatic geometric model evaluation

    Science.gov (United States)

    Pamer, Robert

    2015-04-01

    Quantification of subsurface model reliability is mathematically and technically demanding as there are many different sources of uncertainty and some of the factors can be assessed merely in a subjective way. For many practical applications in industry or risk assessment (e. g. geothermal drilling) a quantitative estimation of possible geometric variations in depth unit is preferred over relative numbers because of cost calculations for different scenarios. The talk gives an overview of several factors that affect the geometry of structural subsurface models that are based upon typical geological survey organization (GSO) data like geological maps, borehole data and conceptually driven construction of subsurface elements (e. g. fault network). Within the context of the trans-European project "GeoMol" uncertainty analysis has to be very pragmatic also because of different data rights, data policies and modelling software between the project partners. In a case study a two-step evaluation methodology for geometric subsurface model uncertainty is being developed. In a first step several models of the same volume of interest have been calculated by omitting successively more and more input data types (seismic constraints, fault network, outcrop data). The positions of the various horizon surfaces are then compared. The procedure is equivalent to comparing data of various levels of detail and therefore structural complexity. This gives a measure of the structural significance of each data set in space and as a consequence areas of geometric complexity are identified. These areas are usually very data sensitive hence geometric variability in between individual data points in these areas is higher than in areas of low structural complexity. Instead of calculating a multitude of different models by varying some input data or parameters as it is done by Monte-Carlo-simulations, the aim of the second step of the evaluation procedure (which is part of the ongoing work) is to